  1. Controlled Compact High Voltage Power Lines

    OpenAIRE

    Postolati V.; Bycova Е.; Suslov V.; Timashova L.; Shakarian Yu.; Kareva S.

    2016-01-01

    Nowadays modern overhead transmission lines (OHL) constructions having several significant differences from conventional ones are being used in power grids more and more widely. Implementation of compact overhead lines equipped with FACTS devices, including phase angle regulator settings (compact controlled OHL), appears to be one of the most effective ways of power grid development. Compact controlled AC HV OHL represent a new generation of power transmission lines embodying recent advanced ...

  2. Controlled Compact High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Postolati V.

    2016-04-01

    Full Text Available Nowadays modern overhead transmission lines (OHL constructions having several significant differences from conventional ones are being used in power grids more and more widely. Implementation of compact overhead lines equipped with FACTS devices, including phase angle regulator settings (compact controlled OHL, appears to be one of the most effective ways of power grid development. Compact controlled AC HV OHL represent a new generation of power transmission lines embodying recent advanced achievements in design solutions, including towers and insulation, together with interconnection schemes and control systems. Results of comprehensive research and development in relation to 110–500kV compact controlled power transmission lines together with theoretical basis, substantiation, and methodological approaches to their practical application are presented in the present paper.

  3. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    Yomi

    Zeki Demir. Department of Landscape Architecture, Faculty of Forestry, Düzce University. Konuralp, 81620 Düzce, Turkey. E-mail: zekidemir@duzce.edu.tr. Tel: +90-380-5421136. Fax: +90-380-5421136. Accepted 18 August, 2010. The proximity effects of high voltage electric power transmission lines on Leyland Cypress.

  4. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    The proximity effects of high voltage electric power transmission lines on Leyland Cypress (xCupressocyparis leylandii (Dallim. and A.B. Jacks.) Dallim) and Japanese Privet (Ligustrum japonicum Thunb.) growth were examined in a private nursery located in Sakarya, Turkey. Five transect were randomly chosen in both ...

  5. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage power lines. 56.12071 Section 56.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley...

  6. A Multiconductor Model of Power Line Communication in Medium-Voltage Lines

    Directory of Open Access Journals (Sweden)

    Lesek Franek

    2017-06-01

    Full Text Available Most power line communication (PLC models are designed to date simulate power lines as two-wire lines. However, in alternating current (AC electrical distribution, the two-wire option is seldom applied, and medium-voltage lines are most often based on the three-phase configuration. In this context, the influence of the ground, which constitutes another conductor with specific parameters, cannot be neglected. Two-wire models are characterized by limited accuracy, not allowing us to simulate certain major phenomena affecting PLC. This, for example, could embody the answer to the question of whether it is more advantageous to transmit a signal independently through each phase, reference the signal with respect to another phase or to use the ground as a reference. This paper discusses a multi-conductor model that eliminates the disadvantages outlined above; the proposed model exploits the multi-conductor telegrapher’s equations. In order to be able to include medium-voltage (MV/ low-voltage (LV transformers in medium-voltage network models, we constituted a transformer model. The designed models were validated on a real medium-voltage network. To be able to evaluate the suitability of the PLC, the noise in the medium voltage network was measured in order to determine the signal-to-noise ratio (SNR.

  7. Efficiency of the Compact Controlled High -Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Postolaty V.M.

    2015-12-01

    Full Text Available The basic theoretical principles to create compact controlled transmission lines are analyzed in the paper. The results of technical and project elaboration of some variants of such type of power transmission lines are presented and the comparison between their technical and economic indicators with those of traditional power transmission lines and foreign analogues is made in the paper. The efficiency of compact controlled transmission lines application to form power systems and to create intersystem ties as well as distribution electric network is also stated in the paper.

  8. Effect of voltage sags on digitally controlled line connected switched-mode power supplies

    DEFF Research Database (Denmark)

    Török, Lajos; Munk-Nielsen, Stig

    2012-01-01

    Different voltage disorders like voltage fluctuations, sags, frequency variations may occur in the power supply networks due to different fault conditions. These deviations from normal operation affects in different ways the line connected devices. Standards were developed to protect and ensure...... of voltage sags is analyzed. Fault tolerant control algorithm was designed, implemented and is discussed. The fault conditions and their effects were investigated at different power levels....

  9. Communication Characteristics of Faulted Overhead High Voltage Power Lines at Low Radio Frequencies

    Directory of Open Access Journals (Sweden)

    Nermin Suljanović

    2017-11-01

    Full Text Available This paper derives a model of high-voltage overhead power line under fault conditions at low radio frequencies. The derived model is essential for design of communication systems to reliably transfer information over high voltage power lines. In addition, the model can also benefit advanced systems for power-line fault detection and classification exploiting the phenomenon of changed conditions on faulted power line, resulting in change of low radio frequency signal propagation. The methodology used in the paper is based on the multiconductor system analysis and propagation of electromagnetic waves over the power lines. The model for the high voltage power line under normal operation is validated using actual measurements obtained on 400 kV power line. The proposed model of faulted power lines extends the validated power-line model under normal operation. Simulation results are provided for typical power line faults and typical fault locations. Results clearly indicate sensitivity of power-line frequency response on different fault types.

  10. The High Voltage Line Becomes a Power Distributor: A Successful Test in Congo Brazzaville

    Directory of Open Access Journals (Sweden)

    A. Omboua

    2006-03-01

    Full Text Available The high line voltage passes over the head but we don’t have electricity to have our mill functioned, we continue to live without the power! In many developing countries, we have a lot of high lines voltage which cross many regions to supply electricity to the main towns or connect to networks the distanced electric stations.These booked lines for supplying electricity to big towns cross a lot of villages whose people broadly poor hope to be supplied with electricity without a suitable solution. However it seems very deplorable that the power conducted by these lines doesn’t profit to surrounding population. Unfortunately, for these villages, the use of classical stations is too expensive to the power distributors because of high cost of investment and production for these potential scattered consumers with the feeble demand of electricity.This paper presents the original solution, settled in 2002 in one of the village located in Congo Brazzaville, and continues to function correctly. It is a new power transformer with one phase called PLX which is connected on one phase of the high line voltage 220kV and which produces extraordinary the low voltage 230 V directly useful by the rural population. This conceived sample for the rural electrification has been dimensioned for the power of 50kVA. A cheap and resistant advice! It requires a large popularization and mainly in sub saharian Africa that has got many opportunities. Outside the role of conduction of the power, the high line voltage distributes it

  11. Predictive Models of Current, Voltage, and Power Losses on Electric Transmission Lines

    Directory of Open Access Journals (Sweden)

    O. M. Bamigbola

    2014-01-01

    Full Text Available A modern and civilized society is so much dependent on the use of electrical energy because it has been the most powerful vehicle for facilitating economic, industrial, and social developments. Electrical energy produced at power stations is transmitted to load centres from where it is distributed to its consumers through the use of transmission lines run from one place to another. As a result of the physical properties of the transmission medium, some of the transmitted power is lost to the surroundings. The overall effect of power losses on the system is a reduction in the quantity of power available to the consumers. An accurate knowledge of transmission losses is hinged on the ability to correctly predict the available current and voltage along transmission lines. Therefore, mathematical physics expressions depicting the evolution of current and voltage on a typical transmission line were formulated, and derived therefrom were models to predict available current and voltage, respectively, at any point on the transmission line. The predictive models evolved as explicit expressions of the space variable and they are in close agreement with empirical data and reality.

  12. Short-Circuit Calculations for a Transmission Line in the Algerian Power Network Compensated by Thyristor Controlled Voltage Regulator

    Directory of Open Access Journals (Sweden)

    ZELLAGUI Mohamed

    2014-10-01

    Full Text Available In this paper, the impact of using the Thyristor Controlled Voltage Regulator (TCVR on short-circuit calculations is studied for a high voltage transmission line in case of a phase to earth fault in the presence of a fault resistance (RF. A 400 kV single transmission line, in the Algerian power network, is used for this study where the line is compensated by TCVR FACTS device to control the voltage and active power of the line. The impact of the fault resistance is studied to reflect its effect on short-circuit calculations including symmetrical current components, transmission line currents, voltage symmetrical components, and transmission line voltages, without and with TCVR. The obtained simulation results match the presented theoretical analysis.

  13. Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels

    Energy Technology Data Exchange (ETDEWEB)

    Stoffel, J. B. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division. Electronics and Computing Technologies Division; Pentecost, E. D. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division; Roman, R. D. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division; Traczyk, P. A. [Argonne National Lab. (ANL), Argonne, IL (United States). Environmental Assessment Division

    1994-11-01

    The aim of this report is to provide background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist preparers and reviewers of the section on alternatives in environmental documents. This report will give the reviewing individual a better appreciation of the factors affecting EMF strengths near high-voltage transmission lines and the approaches that might be used to reduce EMF impacts on humans and other biological species in the vicinity of high-voltage overhead or underground alternating-current (ac) or direct-current (dc) transmission lines.

  14. Simulation of a Narrowband Power Line Communications System over Medium Voltage

    Directory of Open Access Journals (Sweden)

    Nikolaos Chiotellis

    2016-03-01

    Full Text Available Narrowband Power Line Communications (NB-PLCs are investigated as an alternative option for transferring low rate smart grid (SG data via Medium Voltage (MV power lines. In this framework, two variants of orthogonal frequency division multiplexing are examined, namely Filtered-OFDM (F-OFDM and Wavelet-OFDM (W-OFDM, in an attempt to determine which of them is capable of transmitting low rate SG data to greater distances over non-branched MV power lines. The reach of NB-PLC signals via MV power lines is estimated, taking into account the transfer function of the relevant PLC channels and noise mechanisms as well as the specific features of the two modulation options under consideration. Simulations show that NB-PLC transmission constitutes a technically feasible and economically affordable option for exchanging low rate data with remote SG nodes dispersed over the MV grid. Moreover, simulations show that F-OFDM allows low rate data transmission to considerably greater distances compared to W-OFDM.

  15. Use of Rod Compactors for High Voltage Overhead Power Lines Magnetic Field Mitigation

    Directory of Open Access Journals (Sweden)

    Fabio Bignucolo

    2017-09-01

    Full Text Available In the last decades, strengthening the high voltage transmission system through the installation of new overhead power lines has become critical, especially in highly developed areas. Present laws concerning the human exposure to electric and magnetic fields introduce constraints to be considered in both new line construction and existing systems. In the paper, a technique for passive magnetic field mitigation in areas close to overhead power lines is introduced, fully modelled and discussed through a parametric analysis. The investigated solution, which basically consists in approaching line conductors along the span making use of rod insulators, is applicable on both existing and under-design overhead lines as an alternative to other mitigating actions. Making use of a 3-dimensional representation, the procedure computes both positions of phase conductors and forces acting on insulators, towers, conductors and compactors, with the aim of evaluating the additional mechanical stress introduced by the compactors. Finally, a real case study is reported to demonstrate and quantify the benefits in terms of ground magnetic field reduction achievable by applying the proposed solution, in comparison to a traditional configuration. Furthermore, using compactors to passively reduce the magnetic field is simple to be applied, minimally invasive and quite inexpensive as regards to alternative mitigating actions.

  16. Optimization Design of an Inductive Energy Harvesting Device for Wireless Power Supply System Overhead High-Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-03-01

    Full Text Available Overhead high voltage power line (HVPL online monitoring equipment is playing an increasingly important role in smart grids, but the power supply is an obstacle to such systems’ stable and safe operation, so in this work a hybrid wireless power supply system, integrated with inductive energy harvesting and wireless power transmitting, is proposed. The energy harvesting device extracts energy from the HVPL and transfers that from the power line to monitoring equipment on transmission towers by transmitting and receiving coils, which are in a magnetically coupled resonant configuration. In this paper, the optimization design of online energy harvesting devices is analyzed emphatically by taking both HVPL insulation distance and wireless power supply efficiency into account. It is found that essential parameters contributing to more extracted energy include large core inner radius, core radial thickness, core height and small core gap within the threshold constraints. In addition, there is an optimal secondary coil turn that can maximize extracted energy when other parameters remain fixed. A simple and flexible control strategy is then introduced to limit power fluctuations caused by current variations. The optimization methods are finally verified experimentally.

  17. Environmental justice: a contrary finding for the case of high-voltage electric power transmission lines.

    Science.gov (United States)

    Wartenberg, Daniel; Greenberg, Michael R; Harris, Gerald

    2010-05-01

    Environmental justice is the consideration of whether minority and/or lower-income residents in a geographic area are likely to have disproportionately higher exposures to environmental toxins than those living elsewhere. Such situations have been identified for a variety of factors, such as air pollution, hazardous waste, water quality, noise, residential crowding, and housing quality. This study investigates the application of this concept to high-voltage electric power transmission lines (HVTL), which some perceive as a health risk because of the magnetic fields they generate, and also as esthetically unpleasing. We mapped all 345 kV and higher voltage HVTL in New York State and extracted and summarized proximate US Census sociodemographic and housing characteristic data into four categories on the basis of distances from HVTL. Contrary to our expectation, people living within 2000 ft from HVTL were more likely to be exposed to magnetic fields, white, of higher income, more educated and home owners, than those living farther away, particularly in urban areas. Possible explanations for these patterns include the desire for the open space created by the rights-of-way, the preference for new homes/subdivisions that are often located near HVTL, and moving closer to HVTL before EMFs were considered a risk. This study suggests that environmental justice may not apply to all environmental risk factors and that one must be cautious in generalizing. In addition, it shows the utility of geographical information system methodology for summarizing information from extremely large populations, often a challenge in epidemiology.

  18. Calculation of voltages in electric power transmission lines during historic geomagnetic storms: An investigation using realistic earth impedances

    Science.gov (United States)

    Lucas, Greg M.; Love, Jeffrey J.; Kelbert, Anna

    2018-01-01

    Commonly, one-dimensional (1-D) Earth impedances have been used to calculate the voltages induced across electric power transmission lines during geomagnetic storms under the assumption that much of the three-dimensional structure of the Earth gets smoothed when integrating along power transmission lines. We calculate the voltage across power transmission lines in the mid-Atlantic region with both regional 1-D impedances and 64 empirical 3-D impedances obtained from a magnetotelluric survey. The use of 3-D impedances produces substantially more spatial variance in the calculated voltages, with the voltages being more than an order of magnitude different, both higher and lower, than the voltages calculated utilizing regional 1-D impedances. During the March 1989 geomagnetic storm 62 transmission lines exceed 100 V when utilizing empirical 3-D impedances, whereas 16 transmission lines exceed 100 V when utilizing regional 1-D impedances. This demonstrates the importance of using realistic impedances to understand and quantify the impact that a geomagnetic storm has on power grids.

  19. Preterm birth among women living within 600 meters of high voltage overhead Power Lines: a case-control study.

    Science.gov (United States)

    Sadeghi, Taktom; Ahmadi, Amirmasoud; Javadian, Maryam; Gholamian, Sayyed Asghar; Delavar, Mouloud Agajani; Esmailzadeh, Sedigheh; Ahmadi, Bahare; Hadighi, Mozhgan Sadat Hassanpour

    2017-09-26

    The issue of preterm birth due to exposure to magnetic fields from power lines is unclear. Exposure to electromagnetic field in uterus has been hypothesized as possible preterm birth. The aim of the present study was to determine whether living closer to high voltage power lines increased the risk of preterm labor. In a nested case-control study, 135 cases of singleton live spontaneous preterm birth in Rohani hospital, Babol, Iran, during the period between 2013 and 2014 were studied. The 150 control subjects were singleton term live birth in the same year of birth and city of residence using randomized-digit dialing. The shortest distance to any of the high voltage power lines to the maternal residence during pregnancy was measured using ArcGIS software for every case and control. To test the association between the preterm births and the residential proximity to power lines, stepwise multiple logistic regression was used. There were 28 households, 20 cases (14.8%) and 8 controls (5.3%) situated within 600 meters of high voltage power lines. The adjusted OR for spontaneous preterm birth and birth defect in women who were living in less than 600 meters from high voltage power lines was higher compared to those living at farther distance (OR = 3.28, CI: 1.37 to 7.85) and (OR = 5.05, CI: 1.52 to 16.78), respectively. Therefore, installing overhead power lines and stations within 600 meters or making overhead underground would be useful in the prevention of both preterm birth and birth defect.

  20. The influence of lightning induced voltage on the distribution power line polymer insulators.

    Directory of Open Access Journals (Sweden)

    Mahdi Izadi

    Full Text Available Protection of medium voltage (MV overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.

  1. The influence of lightning induced voltage on the distribution power line polymer insulators.

    Science.gov (United States)

    Izadi, Mahdi; Abd Rahman, Muhammad Syahmi; Ab-Kadir, Mohd Zainal Abidin; Gomes, Chandima; Jasni, Jasronita; Hajikhani, Maryam

    2017-01-01

    Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.

  2. Test Results from a Simulated High Voltage Lunar Power Transmission Line

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

  3. Test Results From a Simulated High-Voltage Lunar Power Transmission Line

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was modified to simulate high-voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high-frequency ac power to a lunar facility located at a distance.

  4. High voltage power lines with autonomous sensor nodes; Hochspannungsleitungen mit verteilten Sensornetzen. Erfolgreicher Feldtest. Dauertest geplant

    Energy Technology Data Exchange (ETDEWEB)

    Kurth, Steffen [Fraunhofer ENAS, Chemnitz (Germany); During, Hanjo; Lissek, Sebastian [Envia Verteilnetz GmbH, Halle/Saale (Germany); Grosser, Volker [Fraunhofer-Institut fuer Zuverlaessigkeit und Mikrointegration (IZM), Berlin (Germany)

    2011-10-17

    An autonomous sensor network for power line monitoring was developed. The sensor nodes detect the temperature and the inclination of the conductors. The measured data is transmitted by radio in the 2.4 GHz ISM frequency band from sensor node to each other and to a base station linking monitoring system and the control system. The energy required for the operation of the sensor nodes is harvested from the electric fringing field of the power lines.

  5. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines.

    Science.gov (United States)

    Tourab, Wafa; Babouri, Abdesselam

    2016-06-01

    This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  6. Residential Distance to High-voltage Power Lines and Risk of Neurodegenerative Diseases

    DEFF Research Database (Denmark)

    Frei, Patrizia; Poulsen, Aslak Harbo; Mezei, Gabor

    2013-01-01

    period 5-20 years before diagnosis were computed. The risks for developing dementia, Parkinson's disease, multiple sclerosis, and motor neuron disease were not increased in persons living within close vicinity of a power line. The risk of Alzheimer's disease was not increased for ever living within 50 m...

  7. LONG CORRIDOR SURVEY FOR HIGH VOLTAGE POWER LINES DESIGN USING UAV

    Directory of Open Access Journals (Sweden)

    D. Skarlatos

    2017-11-01

    Full Text Available The term Unmanned Aerial Vehicle (UAV is often directly associated with the armed forces due to their widely-criticized use of such vehicles on the modern battlefield. However, with the advancement of UAV technology, the acquisition and operational cost of small civilian UAV have reduced while their functionalities have increased. Therefore, a wide variety of new civilian applications have emerged. Mapping industry has been benefited as affordable UAV can partially replace traditional platforms, such as helicopters and small aircrafts, for low altitude photography acquisition. Although relatively new to the industry, the use of UAV is rapidly commercialized and they are expected to have a sizeable impact on the mapping industry in the coming years. The aim of this work was to test the use of a low-cost UAV for orthophoto production and Digital Surface Model (DSM creation, to be used for the design of a new 23km high voltage line of Electricity Authority of Cyprus.

  8. Long Corridor Survey for High Voltage Power Lines Design Using Uav

    Science.gov (United States)

    Skarlatos, D.; Vamvakousis, V.

    2017-11-01

    The term Unmanned Aerial Vehicle (UAV) is often directly associated with the armed forces due to their widely-criticized use of such vehicles on the modern battlefield. However, with the advancement of UAV technology, the acquisition and operational cost of small civilian UAV have reduced while their functionalities have increased. Therefore, a wide variety of new civilian applications have emerged. Mapping industry has been benefited as affordable UAV can partially replace traditional platforms, such as helicopters and small aircrafts, for low altitude photography acquisition. Although relatively new to the industry, the use of UAV is rapidly commercialized and they are expected to have a sizeable impact on the mapping industry in the coming years. The aim of this work was to test the use of a low-cost UAV for orthophoto production and Digital Surface Model (DSM) creation, to be used for the design of a new 23km high voltage line of Electricity Authority of Cyprus.

  9. Wireless Power Supply via Coupled Magnetic Resonance for on-line Monitoring Wireless Sensor of High-voltage Electrical Equipment

    DEFF Research Database (Denmark)

    Xingkui, Mao; Qisheng, Huang; Yudi, Xiao

    2016-01-01

    On-line monitoring of high-voltage electrical equipment (HV-EE) aiming to detect faults effectively has become crucial to avoid serious accidents. Moreover, highly reliable power supplies are the key component for the wireless sensors equipped in such on-line monitoring systems. Therefore......, in this paper, the wireless power supply via coupled magnetic resonance (MR-WPS) is proposed for powering the wireless sensor and the associated wireless sensor solution is also proposed. The key specifications of the MR-WPS working in switchgear cabinet with a harsh operation environment are analyzed...... and determined. Design of these key parameters of the coupled magnetic resonant unit (CMRU) in MR-WPS is provided as well as the method of optimizing the resonant windings is given. Finally, a prototype is built and tested. The experimental results are presented in order to show that sufficient and reliable...

  10. The account of sagging of wires at definition of specific potential factors of air High-Voltage Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Suslov V.M.

    2005-12-01

    Full Text Available The opportunity approached is shown, but more exact as it is usually accepted, the account of sagging of wires at definition of specific potential factors air High-Voltage Power Transmission Lines. The technique of reception of analytical expressions is resulted. For an opportunity of comparison traditional expressions for specific potential factors are resulted also. Communication of the offered and traditional analytical expressions is shown. Offered analytical expressions are not difficult for programming on a personal computer of any class and besides they allow to make an estimation of an error of traditional expressions by means of parallel definition of specific potential factors by both ways.

  11. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    OpenAIRE

    POSTOLATI V.M.; E. V. Bykova; SUSLOVI V.M.; SHAKARYAN Ui.G; TIMASHOVA L.V.; KAREVA S.N.

    2010-01-01

    The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL). Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS a...

  12. SYNTHESIS OF ACTIVE SCREENING SYSTEM OF MAGNETIC FIELD OF HIGH VOLTAGE POWER LINES OF DIFFERENT DESIGN TAKING INTO ACCOUNT SPATIAL AND TEMPORAL DISTRIBUTION OF MAGNETIC FIELD

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2017-04-01

    Full Text Available Purpose. Analyze the spatial and temporal distribution of the magnetic field of high voltage power lines with different design allowing and development of recommendations for the design of active screening systems by magnetic field of high voltage power lines. Methodology. Analysis of the spatial and temporal distribution of the magnetic field of high voltage power lines of different design allowing is made on the basis of Maxwell's equations solutions in the quasi-stationary approximation. Determination of the number, configuration, spatial arrangement and the compensation coil currents is formulated in the form of multiobjective optimization problem that is solved by multi-agent multiswarm stochastic optimization based on Pareto optimal solutions. Results of active screening system for the synthesis of various types of transmission lines with different numbers of windings controlled. The possibility of a significant reduction in the level of the flux density of the magnetic field source within a given region of space. Originality. For the first time an analysis of the spatial and temporal distribution of the magnetic field of power lines with different types and based on findings developed recommendations for the design of active screening system by magnetic field of high voltage power lines. Practical value. Practical recommendations on reasonable choice of the number and spatial arrangement of compensating windings of active screening system by magnetic field of high voltage power lines of different design allowing for the spatial and temporal distribution of the magnetic field. Results of active screening system synthesis of the magnetic field of industrial frequency generated by single-circuit 110 kV high voltage power lines with the supports have 330 - 1T «triangle» rotating magnetic field with full polarization in a residential five-storey building, located near the power lines. The system contains three compensating coil and reduces

  13. The Project Outcome “Assessment of the Impact of Medium Voltage Power Lines on Avifauna in Mangistau Region (Kazakhstan”

    Directory of Open Access Journals (Sweden)

    Mark V. Pestov

    2016-02-01

    Full Text Available The article highlights the project results on the assessment of the impact of middle voltage overhead power lines (PL on avifauna of Mangistau region of the Republic of Kazakhstan. On repeated examination of 440 km of PL there was determined a fact of death of 123 birds belonging to 29 species. In particular, 23 birds died from injuries because of collision with wires, and 100 birds were electrocuted. Among the latter, about 60 % are eagles (Steppe Eagle Aquila nipalensis, Golden Eagle Aquila chrysaetos, Imperial Eagle Aquila heliaca. There is the dependence of a number of electrocuted birds on the engineering design of PL. There was an extrapolation of the bird electrocution survey results on the whole territory of Mangistau region.

  14. The Effect of Above-Ground Medium Voltage Power Lines on Displaying Site Selection of the Great Bustard (Otis Tarda in Central Hungary

    Directory of Open Access Journals (Sweden)

    Lóránt Miklós

    2015-02-01

    Full Text Available Our study was conducted in the Upper-Kiskunság region, Central Hungary, which hosts the largest Pannonian population of the Great Bustard (Otis tarda. The influence of the presence of aboveground medium voltage power lines on displaying site selection of Great Bustard males was investigated. The results revealed that displaying males totally reject the sites located within 350-400 m or closer to medium voltage power lines as displaying sites and show relative rejection towards potential displaying sites located at a distance between 500 and 1000 m far from power lines. Surprisingly, the overall negative effects influence much larger part of the potential displaying grounds, up to the distance to 3500 m from power lines. It can be declared that power lines reduce the extent of suitable displaying sites of the Great Bustards in the Upper-Kiskunság region. Accordingly, installation of new above-ground power lines (and other kind of wires, such as high voltage power lines, optical cables etc. would further reduce the extent of suitable displaying sites.

  15. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    Directory of Open Access Journals (Sweden)

    POSTOLATI V.M.

    2010-08-01

    Full Text Available The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL. Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS are formulated. Methodical approaches to the choice of options for transmission lines 220 kV and facilities management are shown.

  16. Effects of nearby buildings on lightning induced voltages on overhead power distribution lines

    OpenAIRE

    Borghetti, Alberto; Napolitano, Fabio; Nucci, Carlo Alberto; Paolone, Mario

    2013-01-01

    For the case of urban overhead lines, the presence of nearby buildings is expected to affect the overvoltages induced by nearby cloud-to-ground lightning return strokes. So far, this effect has been seldom taken into account in the literature on the subject. The paper presents a 3D FEM model that calculates the lightning electromagnetic pulse (LEMP) taking into account the presence of a building placed in proximity of the LEMP-coupled overhead line. As a first approximation, all the metallic ...

  17. 40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.

    Science.gov (United States)

    2010-07-01

    ... requirements are met. (2) Variable voltage AC power transformer, range 100 Vac to 130 Vac, with sufficient... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test for effect of variations in power... METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and...

  18. Living near overhead high voltage transmission power lines as a risk factor for childhood acute lymphoblastic leukemia: a case-control study.

    Science.gov (United States)

    Sohrabi, Mohammad-Reza; Tarjoman, Termeh; Abadi, Alireza; Yavari, Parvin

    2010-01-01

    This study aimed to investigate association of living near high voltage power lines with occurrence of childhood acute lymphoblastic leukemia (ALL). Through a case-control study 300 children aged 1-18 years with confirmed ALL were selected from all referral teaching centers for cancer. They interviewed for history of living near overhead high voltage power lines during at least past two years and compared with 300 controls which were individually matched for sex and approximate age. Logistic regression, chi square and paired t-tests were used for analysis when appropriate. The case group were living significantly closer to power lines (Plines (Plines against more than 600 meters. This ratio estimated as 9.93 (95%CI: 3.47 to 28.5) for 123 KV, 10.78 (95%CI: 3.75 to 31) for 230 KV and 2.98 (95%CI: 0.93 to 9.54) for 400 KV lines. Odds of ALL decreased 0.61 for every 600 meters from the nearest power line. This study emphasizes that living close to high voltage power lines is a risk for ALL.

  19. Image registration algorithm for high-voltage electric power live line working robot based on binocular vision

    Science.gov (United States)

    Li, Chengqi; Ren, Zhigang; Yang, Bo; An, Qinghao; Yu, Xiangru; Li, Jinping

    2017-12-01

    In the process of dismounting and assembling the drop switch for the high-voltage electric power live line working (EPL2W) robot, one of the key problems is the precision of positioning for manipulators, gripper and the bolts used to fix drop switch. To solve it, we study the binocular vision system theory of the robot and the characteristic of dismounting and assembling drop switch. We propose a coarse-to-fine image registration algorithm based on image correlation, which can improve the positioning precision of manipulators and bolt significantly. The algorithm performs the following three steps: firstly, the target points are marked respectively in the right and left visions, and then the system judges whether the target point in right vision can satisfy the lowest registration accuracy by using the similarity of target points' backgrounds in right and left visions, this is a typical coarse-to-fine strategy; secondly, the system calculates the epipolar line, and then the regional sequence existing matching points is generated according to neighborhood of epipolar line, the optimal matching image is confirmed by calculating the similarity between template image in left vision and the region in regional sequence according to correlation matching; finally, the precise coordinates of target points in right and left visions are calculated according to the optimal matching image. The experiment results indicate that the positioning accuracy of image coordinate is within 2 pixels, the positioning accuracy in the world coordinate system is within 3 mm, the positioning accuracy of binocular vision satisfies the requirement dismounting and assembling the drop switch.

  20. Analysis of overvoltages in overhead ground wires of extra high voltage (EHV) power transmission line under single-phase-to-ground faults

    NARCIS (Netherlands)

    Dudurych, [No Value; Rosolowski, E

    2000-01-01

    Overhead ground wires (GW) of extra high voltage (EHV) power transmission lines, apart from lightning-induced overvoltage protection are frequently used for carrier-current communication. In this case the ground wires are suspended on insulators, the dielectric strength of which should be sufficient

  1. Low power, scalable multichannel high voltage controller

    Science.gov (United States)

    Stamps, James Frederick [Livermore, CA; Crocker, Robert Ward [Fremont, CA; Yee, Daniel Dadwa [Dublin, CA; Dils, David Wright [Fort Worth, TX

    2008-03-25

    A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

  2. LED-Based High-Voltage Lines Warning System

    Directory of Open Access Journals (Sweden)

    Eldar MUSA

    2013-04-01

    Full Text Available LED-based system, running with the current of high-voltage lines and converting the current flowing through the line into the light by using a toroid transformer, has been developed. The transformer’s primary winding is constituted by the high voltage power line. Toroidal core consists of two equal parts and the secondary windings are evenly placed on these two parts. The system is mounted on the high-voltage lines as a clamp. The secondary winding ends are connected in series by the connector on the clamp. LEDs are supplied by the voltage at the ends of secondary. Current flowing through highvoltage transmission lines is converted to voltage by the toroidal transformer and the light emitting LEDs are supplied with this voltage. The theory of the conversion of the current flowing through the line into the light is given. The system, running with the current of the line and converting the current into the light, has been developed. System has many application areas such as warning high voltage lines (warning winches to not hinder the high-voltage lines when working under the lines, warning planes to not touch the high-voltage lines, remote measurement of high-voltage line currents, and local illumination of the line area

  3. Performance analysis of the PLC (Power Line Communication) in medium voltage electrical networks; Analise de desempenho de sistemas PLC em redes eletricas de media tensao

    Energy Technology Data Exchange (ETDEWEB)

    Mota, A.A.; Paleta, R. [Pontificia Universidade Catolica de Campinas (PUC-Campinas), SP (Brazil)], E-mail: amota@puc-campinas.edu.br; Mota, L.T.M.; Ricardo, R.A. [Indelmatec Engenharia, Campinas, SP (Brazil)], E-mail: mota@indelmatec.com.br

    2009-07-01

    Nowadays, the information access in communication networks is widely explored due to the increase of Internet users. In this context, the PLC (Power Line Communication) technology is an alternative for data transmission. This technology is based on the usage of transmission/distribution power lines for data transmission. However there are some problems related to the usage of this technology: adequate data transmission rates and generation of acceptable levels of electromagnetic interference (EMI). This work had the objective of studying the performance of PLC systems in medium voltage electrical networks, through the assess of data transmission rates and the generated EMI. Tests were carried out in a test field that corresponded to a medium voltage electrical network and the obtained results show that, under some circumstances, the PLC system does not reach the existent technical recommendations. (author)

  4. LTPS-TFT Pixel Circuit Compensating for TFT Threshold Voltage Shift and IR-Drop on the Power Line for AMOLED Displays

    Directory of Open Access Journals (Sweden)

    Ching-Lin Fan

    2012-01-01

    Full Text Available We propose a new pixel design for the active matrix organic light-emitting diode (AMOLED using low-temperature polycrystalline silicon thin-film transistors (LTPS-TFTs. The proposed pixel is composed of four switching TFTs, one driving TFT (DTFT, and one capacitor. The simulation results are performed by AIM-SPICE software. The error rate of OLED output current with (threshold voltage variation (0.3 V and power line drop by 1 V are improved to about 1.67% and 15%, respectively. Thus, the proposed pixel circuit can successfully overcome drawbacks suffered from DTFT threshold voltage deviation and IR-drop on power line.

  5. Control voltage and power fluctuations when connecting wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Berinde, Ioan, E-mail: ioan-berinde@yahoo.com; Bălan, Horia, E-mail: hbalan@mail.utcluj.ro; Oros, Teodora Susana, E-mail: teodoraoros-87@yahoo.com [Technical University of Cluj-Napoca, Romania, Faculty of Electrical Engineering, Department of Power Engineering and Management (Romania)

    2015-12-23

    Voltage, frequency, active power and reactive power are very important parameters in terms of power quality. These parameters are followed when connecting any power plant, the more the connection of wind farms. Connecting wind farms to the electricity system must not cause interference outside the limits set by regulations. Modern solutions for fast and automatic voltage control and power fluctuations using electronic control systems of reactive power flows. FACTS (Flexible Alternating Current Transmision System) systems, established on the basis of power electronic circuits ensure control of electrical status quantities to achieve the necessary transfer of power to the power grid. FACTS devices can quickly control parameters and sizes of state power lines, such as impedance line voltages and phase angles of the voltages of the two ends of the line. Their use can lead to improvement in power system operation by increasing the transmission capacity of power lines, power flow control lines, improved static and transient stability reserve.

  6. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  7. Understanding Local Policy Elites' Perceptions on the Benefits and Risks Associated with High-Voltage Power Line Installations in the State of Arkansas.

    Science.gov (United States)

    Moyer, Rachael M; Song, Geoboo

    2016-10-01

    Recently, a controversial policy debate has arisen concerning the installation of high-voltage power lines in northwest Arkansas. While proponents argue that such an installation is inevitable to efficiently and reliably support the identified electric load in the region, opponents claim that the lines will degrade the natural environment and hamper the tourism-based local economy in affected regions, notably in Ozark Mountain areas. Of particular interest is to understand how local policy elites perceive the benefits and risks associated with such divisive proposals, which is critical for comprehending the formation and changes of related government policies. Based upon the dual process theory of judgment, this study systematically investigates the triadic relationships between (a) more profound personal value predispositions, (b) affects and feelings, and (c) perceived benefits and risks related to the proposed installation of high-voltage power lines among local policy elites in the state of Arkansas. In doing so, we analyze original data collected from a statewide Internet survey of 420 local leaders and key policymakers about their opinions on the related issues, while considering other factors claimed by previous literature to influence risk perceptions, including trust, knowledge level, and demographic characteristics. Analytical results suggest that grid-group cultural predispositions, as deeply held core values within local policy elites' individual belief systems, both directly and indirectly-through affective feelings-shape perceived utility associated with the installation of high-voltage power lines. We conclude this article by suggesting some practical considerations for better designing policy addressing controversial issues of this nature. © 2016 Society for Risk Analysis.

  8. Applications of high-temperature superconductors in power technology[8470 High-current and high-voltage technology: power systems; power transmission lines and cables;

    Energy Technology Data Exchange (ETDEWEB)

    Hull, John R [Energy Technology Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2003-11-01

    Since the discovery of the first high-temperature superconductors (HTSs) in the late 1980s, many materials and families of materials have been discovered that exhibit superconductivity at temperatures well above 20 K. Of these, several families of HTSs have been developed for use in electrical power applications. Demonstration of devices such as motors, generators, transmission lines, transformers, fault-current limiters, and flywheels in which HTSs and bulk HTSs have been used has proceeded to ever larger scales. First-generation wire, made from bismuth-based copper oxides, was used in many demonstrations. The rapid development of second-generation wire, made by depositing thin films of yttrium-based copper oxide on metallic substrates, is expected to further accelerate commercial applications. Bulk HTSs, in which large single-grain crystals are used as basic magnetic components, have also been developed and have potential for electrical power applications.

  9. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  10. 30 CFR 75.705-2 - Repairs to energized surface high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized surface high-voltage lines... Repairs to energized surface high-voltage lines. An energized high-voltage surface line may be repaired... on power circuits with a phase-to-phase nominal voltage no greater than 15,000 volts; (3) Such...

  11. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wafa Tourab

    2016-06-01

    Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  12. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  13. Synthesis of MnO2 nanoparticles and their effective utilization as UV protectors for outdoor high voltage polymeric insulators used in power transmission lines.

    Science.gov (United States)

    Ghosh, Dipankar; Bhandari, Subhendu; Khastgir, Dipak

    2016-12-07

    Polymeric outdoor insulators derived from polydimethyl siloxane (PDMS) are replacing conventional ceramic insulators in high voltage power transmission lines because of their improved electrical, mechanical and hydrophobic performance. Major impediments like failure of polymeric insulators due to natural aging by UV radiation from sunlight and electrical tracking have limited their usage. Herein, it is demonstrated about the usage of manganese dioxide based nanoparticles as an effective agent to prevent the UV accelerated aging of polymeric insulators. MnO2 nanoparticles of different shapes and dimension were synthesized using a single step wet chemical reaction between KMnO4 and methyl acetate. Namely, 2D δ-MnO2 nanosheets, 1D α-MnO2 nanowires and 3D α-MnO2 nanorods were formed. These nanoparticles were extensively characterized by various techniques. In the scope of the study, the δ-MnO2 (10-5 S cm-1; 1 MHz) nanosheet demonstrated the lowest electrical AC conductivity and a higher band gap compared to the 1D (10-4 S cm-1; 1 MHz) and 3D variety (10-4 S cm-1; 1 MHz). Owing to the lower electrical conductivity of the δ-MnO2 nanosheet, it was further incorporated at different filler volumes in the polymeric matrix (blend of polydimethyl siloxane/ethylene vinyl acetate) as a UV protector material for the polymer based high voltage composite polymeric insulator. The UV protection ability, induced by the δ-MnO2 nanosheet, was achieved without adversely affecting other properties of the formulated insulator compound material. The optimum properties of the composite were found to be obtained at 3 phr (three parts of δ-MnO2 nanosheet per hundred parts of polymer) loading of the nanosheet. The current work will promise to pave a new pathway for the generation of UV resistant high voltage power transmission line insulator materials. It would be interesting in the future to study the effect of incorporation of manganese dioxide based nanosheets on the UV resistant

  14. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  15. Memory loss risk assessment for the students nearby high-voltage power lines-a case study.

    Science.gov (United States)

    Ghadamgahi, Mojgan; Monazzam, Mohammad Reza; Hosseini, Monireh

    2016-06-01

    With increasing sources of alternating current electromagnetic fields (EMFs) in everyday life, their possible harmful effects on human health are a main area of concern in many countries. Given that children are the most valuable assets of each country, it is of utmost importance to study the effect(s) of EMF exposure on various health aspects of members within this age group. The present research is the first systematic study of the effects of exposure to electric substations on the memory status of male students in the age group of 10 to 12 years. The flux density values of extremely low frequency magnetic field were measured at four elementary schools in Tehran in accordance with IEEE std 644-1994. The device was 3-axis (X, Y, and Z) Gauss Meter, model: TES-1394. The students from two schools nearby a high voltage electricity substation (at distances of 30 and 50 m) were selected as the exposed group, and the students of two other schools at further distances of 1390 and 610 m were considered as the control group. To determine the status of working memory in the students, the questionnaire was adapted from Wechsler Intelligence Scale for Children (WISC-IV). The completed questionnaires were analyzed by t test and chi-square using SPSS 20. The average magnetic flux density was 0.245 μT at case schools and 0.164 μT at control schools, P < 0.01. The demographic characteristics of the students in the two groups were not statistically different. However, the difference in working memory was significant at the level of 5 %. The results of the questionnaire data showed that students in the control group had better working memory compared to students in case group. The findings revealed a reverse correlation between magnetic flux density and working memory of students (R = -0.255). It is concluded that extremely low frequency magnetic field exposure may have a negative impact on the working memory of children, but further studies are necessary to reach a

  16. Signal Transmission on Power Lines

    DEFF Research Database (Denmark)

    Dalby, Arne Brejning

    1997-01-01

    coupled transmission line circuits like power line circuits, is based on finding the eigenvalues and eigenvectors for the matrix ZY, where Z and Y are the impedance- and admittance matrices for the coupled lines in W/m and S/m. In this paper a flow-graph representation of the relations beween voltage......- and current-vectors is presented for a general coupled line circuit. This flow-graph can be used to find any transfer function on a multiple coupled lossy transmission line circuit. In some cases, however, it is difficult to find the eigenvalues correctly. A correct analysis can thus not be made......In the analysis of power-line networks over a large frequency span, the time-domain method used in programs like EMTP (Electromagnetic Time domain Program) can not be used. A more rigorous analysis method must be employed. The correct analysis method (assuming TEM-mode propagation) for multiple...

  17. Distance to high-voltage power lines and risk of childhood leukaemia – an analysis of confounding by and interaction with other potential risk factors

    DEFF Research Database (Denmark)

    Pedersen, Camilla; Bräuner, Elvira V.; Rod, Naja H.

    2014-01-01

    the association between distance to nearest power line and childhood leukemia. We included 1024 cases aged ... significant interaction between distance to nearest power line and domestic radon regarding risk of childhood leukemia (p = 0.01) when using the median radon level as cut-off point but not when using the 75th percentile (p = 0.90). We found no evidence of an interaction between distance to nearest power line...... pollution. The statistically significant interaction between distance to nearest power line and domestic radon was based on few exposed cases and controls and sensitive to the choice of exposure categorization and might, therefore, be due to chance....

  18. High-voltage power supply unit

    CERN Document Server

    Garipov, G K; Silaev, A A; Shirokov, A V

    2002-01-01

    A unit comprising four high-voltage power sources (HPS) is designed for power supply of four independent photomultipliers. Each HPS comprises a pulse-width modulator, digital-to-analog converter, base voltage source and digital interface. HPS unit supplies up to 2000 V output voltage, up to 2.5 mA current and long-term stability equal to +- 0.03%

  19. Power-MOSFET Voltage Regulator

    Science.gov (United States)

    Miller, W. N.; Gray, O. E.

    1982-01-01

    Ninety-six parallel MOSFET devices with two-stage feedback circuit form a high-current dc voltage regulator that also acts as fully-on solid-state switch when fuel-cell out-put falls below regulated voltage. Ripple voltage is less than 20 mV, transient recovery time is less than 50 ms. Parallel MOSFET's act as high-current dc regulator and switch. Regulator can be used wherever large direct currents must be controlled. Can be applied to inverters, industrial furnaces photovoltaic solar generators, dc motors, and electric autos.

  20. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    and maximum output power. In chapter 3, a detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based....... • If optimally designed, boost converters will be much more efficient than comparable buck type converters for high power low voltage applications. • The use of voltage clamp circuits to protect primary switches in boost converters is no longer needed for device protection. On the other hand...

  1. 30 CFR 77.704-2 - Repairs to energized high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Repairs to energized high-voltage lines. 77.704... UNDERGROUND COAL MINES Grounding § 77.704-2 Repairs to energized high-voltage lines. An energized high-voltage... repairs will be performed on power circuits with a phase-to-phase nominal voltage no greater than 15,000...

  2. Voltage Control in Wind Power Plants with Doubly Fed Generators

    DEFF Research Database (Denmark)

    Garcia, Jorge Martinez

    the reactive power operation of the converters, in steadystate, within a maximum band of 10 %. It is clear that an on-load tap changer system will help to keep the stator voltage close to its nominal value, but the action of the mechanically switched capacitors is badly influencing the on-load tap changer line......In this work, the process of designing a wind power plant composed of; doubly fed induction generators, a static compensator unit, mechanically switched capacitors and on-load tap changer, for voltage control is shown. The selected control structure is based on a decentralized system, since...... measured current at medium voltage, thus reducing the tap moving operations. Finally, due to the wind power plant reactive power is sized for maximum active power level, it is expected that a big amount of reactive power remains unused most of the time due to the wind power generation characteristics...

  3. 49 CFR 236.551 - Power supply voltage; requirement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply voltage; requirement. 236.551 Section... supply voltage; requirement. The voltage of power supply shall be maintained within 10 percent of rated voltage. ...

  4. Depressão em trabalhadores de linhas elétricas de alta tensão Depression in high voltage power line workers

    Directory of Open Access Journals (Sweden)

    Suerda Fortaleza de Souza

    2012-06-01

    Full Text Available OBJETIVO: Investigar a associação entre desequilíbrio esforços-recompensas no trabalho e sintomas depressivos em trabalhadores de linhas elétricas de alta tensão. MÉTODOS: Estudo de corte transversal realizado em 158 trabalhadores de uma empresa de energia elétrica no Nordeste do Brasil. As dimensões do modelo esforço-recompensa (ERI constituíram as variáveis independentes principais e a variável resposta foi depressão, medida pela escala Center for Epidemiologic Studies Depression (CES-D. Os dados foram analisados com técnicas de regressão logística múltipla. RESULTADOS: Trabalhadores no grupo de baixa recompensa apresentaram prevalência de depressão 6,2 vezes maior em relação àqueles no grupo de alta recompensa. A prevalência de depressão foi 3,3 vezes maior entre os trabalhadores em condição de desequilíbrio esforço-recompensa do que entre aqueles em situação de equilíbrio. CONCLUSÕES: A prevalência de depressão estava fortemente associada às dimensões de esforços e recompensas presentes no trabalho dos eletricitários.OBJECTIVE: To investigate the association between effort-reward imbalance and depressive symptoms among workers in high voltage power lines. METHODS: A cross-sectional study among 158 workers from an electric power company in Northeast Brazil. The main independent variables were the Effort-Reward Imbalance Model (ERI dimensions and the main dependent variable was the prevalence of depression, as measured by the Center for Epidemiologic Studies Depression (CES-D scale. Data were analyzed by multiple logistic regression techniques. RESULTS: The group of low reward workers presented a depression prevalence rate 6.2 times greater than those in the high reward group. The depression prevalence rate was 3.3 greater in workers in the situation of imbalanced effort-reward than in those in effort-reward equilibrium. CONCLUSIONS: The prevalence of depression was strongly associated with psychosocial

  5. High Efficiency Power Converter for Low Voltage High Power Applications

    DEFF Research Database (Denmark)

    Nymand, Morten

    . A detailed analysis of dominant loss factors in high power converters for low voltage applications is presented. The analysis concludes that: • Power transformers for low voltage high power, if properly designed, will have extremely low leakage inductance. • If optimally designed, boost converters......The topic of this thesis is the design of high efficiency power electronic dc-to-dc converters for high-power, low-input-voltage to high-output-voltage applications. These converters are increasingly required for emerging sustainable energy systems such as fuel cell, battery or photo voltaic based......, if a converter is properly designed, primary side voltage clamp circuits will not even work in low voltage high power converters. • Very high conversion efficiency can be achieved. Peak efficiency of 98% and worst case minimum efficiency of 96.8% are demonstrated on a 1.5 kW converter. The ability...

  6. Electric Power Transmission Lines

    Data.gov (United States)

    Department of Homeland Security — Transmission Lines are the system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power...

  7. E-beam high voltage switching power supply

    Science.gov (United States)

    Shimer, Daniel W.; Lange, Arnold C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  8. Shaping the spectra of the line-to-line voltage using signal injection in the common mode voltage

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Rasmussen, Peter Omand; Pedersen, John Kim

    2009-01-01

    A drawback of Pulse Width Modulation in electrical drives is the high harmonic content of the line to line voltages, which gives rise to Electro-Magnetic Interference and acoustic noise. By injection of a signal into the common mode voltage, the fundamental is not affected, but new frequency...... components are introduced in the line to line voltage spectrum. This paper introduces a new analytical method for estimation of the line to line voltage spectrum, where sinusoidal signal is injected into the common mode voltage. Based on the analytical calculations, also a new fixed carrier frequency quasi...

  9. Feasibility of high-speed power line carrier system to Japanese overhead low voltage distribution lines; Teiatsu haidensen hanso no kosokuka no kanosei (hanso sningo denpa purogram no kanosei)

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, T.; Takeshita, K.; Ishino, R.

    2000-06-01

    The high-speed distribution line carrier systems on underground distribution lines are being developed in Germany. To estimate these systems on Japanese overhead low voltage distribution lines, the Carrier Propagation Program has been developed and applicability of OFDM system was roughly estimated. 1. Carrier Propagation Program Carrier Propagation Program that calculates the carrier propagation characteristics of any line structure was developed. 2. Carrier propagation characteristics Carrier propagation characteristics on typical Japanese overhead low voltage distribution lines were calculated 3.Rough estimation of OFDM system Electric fields caused by carrier at near point were calculated on the basis on carrier propagation characteristics. Results of rough estimation are as follows: - Electric field caused by carrier of more than 2Mbps system exceeds the value of the regulation. (author)

  10. Optimal placement of unified power flow controllers to improve dynamic voltage stability using power system variable based voltage stability indices.

    Science.gov (United States)

    Albatsh, Fadi M; Ahmad, Shameem; Mekhilef, Saad; Mokhlis, Hazlie; Hassan, M A

    2015-01-01

    This study examines a new approach to selecting the locations of unified power flow controllers (UPFCs) in power system networks based on a dynamic analysis of voltage stability. Power system voltage stability indices (VSIs) including the line stability index (LQP), the voltage collapse proximity indicator (VCPI), and the line stability index (Lmn) are employed to identify the most suitable locations in the system for UPFCs. In this study, the locations of the UPFCs are identified by dynamically varying the loads across all of the load buses to represent actual power system conditions. Simulations were conducted in a power system computer-aided design (PSCAD) software using the IEEE 14-bus and 39- bus benchmark power system models. The simulation results demonstrate the effectiveness of the proposed method. When the UPFCs are placed in the locations obtained with the new approach, the voltage stability improves. A comparison of the steady-state VSIs resulting from the UPFCs placed in the locations obtained with the new approach and with particle swarm optimization (PSO) and differential evolution (DE), which are static methods, is presented. In all cases, the UPFC locations given by the proposed approach result in better voltage stability than those obtained with the other approaches.

  11. Study of a High Voltage Ion Engine Power Supply

    Science.gov (United States)

    Stuart, Thomas A.; King, Roger J.; Mayer, Eric

    1996-01-01

    A complete laboratory breadboard version of a ion engine power converter was built and tested. This prototype operated on a line voltage of 80-120 Vdc, and provided output ratings of 1100 V at 1.8 kW, and 250 V at 20 mA. The high-voltage (HV) output voltage rating was revised from the original value of 1350 V at the beginning of the project. The LV output was designed to hold up during a 1-A surge current lasting up to 1 second. The prototype power converter included a internal housekeeping power supply which also operated from the line input. The power consumed in housekeeping was included in the overall energy budget presented for the ion engine converter. HV and LV output voltage setpoints were commanded through potentiometers. The HV converter itself reached its highest power efficiency of slightly over 93% at low line and maximum output. This would dip below 90% at high line. The no-load (rated output voltages, zero load current) power consumption of the entire system was less than 13 W. A careful loss breakdown shows that converter losses are predominately Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) conduction losses and HV rectifier snubbing losses, with the rectifier snubbing losses becoming predominant at high line. This suggests that further improvements in power efficiency could best be obtained by either developing a rectifier that was adequately protected against voltage overshoot with less snubbing, or by developing a pre-regulator to reduced the range of line voltage on the converter. The transient testing showed the converter to be fully protected against load faults, including a direct short-circuit from the HV output to the LV output terminals. Two currents sensors were used: one to directly detect any core ratcheting on the output transformer and re-initiate a soft start, and the other to directly detect a load fault and quickly shut down the converter for load protection. The finished converter has been extensively fault tested

  12. Power Capability in Low Voltage DC Distribution Systems

    Directory of Open Access Journals (Sweden)

    C.O. Gecan

    2009-12-01

    Full Text Available Recent developments in power electronics components enable the use of power electronics in Low Voltage (LV networks. This development makes the model of a Low Voltage Direct Current (LVDC distribution system possible. The technical and economical benefits of this technology make possible the alternative hypothesis of using DC instead of AC distribution systems. Some aspects, such as increasing the capability of the existing lines, interconnecting distributed generation units and even supplying in DC some loads are creating additional requirements of using a LVDC distribution system. The paper presents some general considerations regarding cables used in a LVAC distribution system and different line reconfigurations witch enable the use of cobles in a LVDC distribution system. The reconfigurations are presented in respect of the DC network topologies: unipolar and bipolar. The central aim of this paper is to investigate capability of power transmission and to calculate the transmission distance for cables used in Low Voltage AC and DC distribution systems. Capability computation is considered in respect of two constrains imposed in the cables cross section selection: cable thermal limit and the maximum allowable voltage drop. Cable thermal limit is represented in calculations by the maximum rated current. The equations used to calculate the power capability are presented for single-phase and threephase AC networks and unipolar and bipolar DC networks. Based on these equations, comparisons between power capability of cables with different cross sections used in Low Voltage DC and AC distribution systems are realized and presented.

  13. Prediction of Line Voltage Stability Index Using Supervised Learning

    Directory of Open Access Journals (Sweden)

    Ankit Kumar Sharma

    2017-12-01

    Full Text Available In deregulated environment, stability issues have become dominant. Reliability of the power is essential for successful operation of the power system. Often high and dynamic loading conditions present new challenges in terms of decision of the control strategies to the system operator at energy management centre. For the achievement of voltage stability, identification of weak buses is very important. Line stability indices are important predictors of the weak buses in the over loaded system. Identification of the weak buses is the first step of control strategy. This paper presents an effective methodology based on Artificial Neural Network (ANN to predict the Fast Voltage Stability Index (FVSI. Comparative analysis of different topologies of ANN is carried out based on the capability of the prediction of FVSI. Results are validated through offline Newton Raphson (NR simulation method. The proposed methodology is tested over IEEE-14 and IEEE-30 test bus System.

  14. BPL (Broadband Power Line)

    OpenAIRE

    Peralta, Arturo

    2010-01-01

    El mundo actual requiere cada vez más el estar conectados con la sociedad de la Información y el Conocimiento, esto demanda que en los hogares, lugares de turismo, trabajos, universidades, etcétera, se cuente con una conexión a Internet de Alta Velocidad, que además sea segura y confiable. En este documento se presenta las características más importantes de la tecnología BPL (Broadband Power Line) o PLC (Power Line Comunication), la cual permite brindar el servicio de Internet ...

  15. Report about the contribution of new technologies to the burial of high and very-high voltage power lines; Rapport sur l'apport de nouvelles technologies dans l'enfouissement des lignes electriques a haute et tres haute tension

    Energy Technology Data Exchange (ETDEWEB)

    Kert, Ch. [Assemblee Nationale, 75 - Paris (France)

    2001-12-01

    Today, high voltage overhead power lines are badly perceived by the population in particular in urban areas and in areas with remarkable landscapes, for their visual impact on the environment and for their possible effect on human health. With the increase of the domestic and foreign power demand, the high voltage grid will develop in the future and the partial burial of power lines can be the first steps towards a solution to these problems. This report makes a worldwide status of the state-of-the-art of power line burial technologies, all voltages considered, and then focusses on the very-high voltage challenge which encounters the most important technological and economical constraints. The technical feasibility has been proven but the lowering of costs needs the development of a real European market of power lines burial. (J.S.)

  16. Distributed Low Voltage Ride-Through Operation of Power Converters in Grid-Connected Microgrids under Voltage Sags

    DEFF Research Database (Denmark)

    Zhao, Xin; Meng, Lexuan; Dragicevic, Tomislav

    2015-01-01

    it can make the MG a contributor in smooth ride through the faults. In this paper, a reactive power support strategy using droop controlled converters is proposed to aid MG riding through three phase symmetrical voltage sags. In such a case, the MGs should inject reactive power to the grid to boost...... the voltage in all phases at AC common bus. However, since the line admittances from each converter to point of common coupling (PCC) are not identical, the injected reactive power may not be equally shared. In order to achieve low voltage ride through (LVRT) capability along with a good power sharing...

  17. Artificial neural networks in high voltage transmission line problems

    Science.gov (United States)

    Ekonomou, L.; Kontargyri, V. T.; Kourtesi, St.; Maris, T. I.; Stathopulos, I. A.

    2007-07-01

    According to the literature high voltage transmission line problems are faced using conventional analytical methods, which include in most cases empirical and/or approximating equations. Artificial intelligence and more specifically artificial neural networks (ANN) are addressed in this work, in order to give accurate solutions to high voltage transmission line problems using in the calculations only actual field data. Two different case studies are studied, i.e., the estimation of critical flashover voltage on polluted insulators and the estimation of lightning performance of high voltage transmission lines. ANN models are developed and are tested on operating high voltage transmission lines and polluted insulators, producing very satisfactory results. These two ANN models can be used in electrical engineers' studies aiming at the more effective protection of high voltage equipment.

  18. On-Line Voltage Stability Assessment based on PMU Measurements

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; P. Da Silva, Luiz C.; Nielsen, Arne Hejde

    2009-01-01

    through statistic analysis. During the off-line analysis, a memory of high-risk situations following a pre-defined voltage stability criterion is obtained. Thereafter, basic statistics analyses are applied resulting in the definition of voltage regions. During on-line operation, voltage magnitudes...... of critical buses obtained by phasor measurements are monitored in relation to the risk regions. Comprehensive studies demonstrate that the proposed method could assist operators to avoid voltage collapse events, by taking preventive or emergency actions.......This paper presents a method for on-line monitoring of risk voltage collapse based on synchronised phasor measurement. As there is no room for intensive computation and analysis in real-time, the method is based on the combination of off-line computation and on-line monitoring, which are correlated...

  19. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  20. Wattmeter for Voltage, Current, Power and Power Factor Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Y. T.; Yu, K. M.; Ryu, K. S.; Kim, H. J. [Korea Research Institute of Standards and Science, Taejeon (Korea); Jang, S. M. [Chungnam National University, Taejeon (Korea)

    2002-07-01

    High precision voltages, currents, power factor and electrical power measurements wide range of frequency can be achieved by using the thermo-elements(thermal converters). This paper describes the development wattmeter, based on a thermal principle. The instrument has been performed measurement in the range of currents from 0 to 50 A, voltages up to 600 V, power factor 0.5, 1 and frequencies from 45 Hz to 3 kHz. The thermal converters with two heater are used in the functional element of the wattmeter. (author). 5 refs., 7 figs.

  1. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  2. Multiagent voltage and reactive power control system

    Directory of Open Access Journals (Sweden)

    I. Arkhipov

    2014-12-01

    Full Text Available This paper is devoted to the research of multiagent voltage and reactive power control system development. The prototype of the system has been developed by R&D Center at FGC UES (Russia. The control system architecture is based on the innovative multiagent system theory application that leads to the achievement of several significant advantages (in comparison to traditional control systems implementation such as control system efficiency enhancement, control system survivability and cyber security.

  3. Transmission Line Adapted Analytical Power Charts Solution

    Science.gov (United States)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2017-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  4. Site Selection Strategy of Single-Frequency Tuned R-APF for Background Harmonic Voltage Damping in Power Systems

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Zeng, Jian; Chen, Zhe

    2013-01-01

    Series resonance between capacitance and line inductance may magnify background harmonic voltage and worsen the harmonic voltage distortion in power systems. To solve this problem, in this paper, the transmission line theory is used to set up the distributed parameter model of power system feeders......, and analyze the harmonic voltage propagation caused by the background harmonic voltage in power systems. Then, a new strategy is proposed for the site selection of resistive active power filter to damp the background harmonic voltage in power systems. Experiments have been performed to verify the theoretical...

  5. APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Y. L. Anokhin

    2017-12-01

    Full Text Available Introduction. Determination of power quality indices in high-voltage power grids allows to find the reasons for the deterioration of the power quality. The relevant national and International Standards for power quality contain relevant norms of quality indices and requirements for their accuracy measurement. Problem. The most complicated part in the process of measuring the power quality indices at high voltage is the selection of the corresponding high-voltage scale voltage converters. Therefore, comparing the requirements of IEC 61000-4-30 to high voltage scale voltage converters is an important task. Goal. Analysis of the International Standard IEC 61000-4-30 requirements feasibility for measuring the indices of power quality in high-voltage electrical networks using different types of high-voltage scale voltage converters. Methodology. Comparison of the requirements of IEC 61000-4-30 Standard to high-voltage scale voltage converters, when measuring power quality indices, with the characteristics of high voltage electromagnetic transformers used in Ukraine, and with promising developments of high-voltage converters of other types. Results. It is shown in the study that in order to fulfill some of the requirements for class A of IEC 61000-4-30, the characteristics of electromagnetic voltage transformers should be determined in the substation conditions using mobile calibration high-voltage laboratories. To meet all the requirements for Class A IEC 61000-4-30, it is recommended to use broadband high-voltage dividers of resistive-capacitive type. Originality. In study it is shown firstly that all the requirements of the IEC 61000-4-30 Standard for high-voltage scale voltage converters can be performed on the basis of the use of broadband resistive-capacitive damped voltage dividers. Practical value. Expositions of specific types of resistive-capacitive high-voltage dividers are presented, their parameters are confirmed by the results of state

  6. Power converters for medium voltage networks

    CERN Document Server

    Islam, Md Rabiul; Zhu, Jianguo

    2014-01-01

    This book examines a number of topics, mainly in connection with advances in semiconductor devices and magnetic materials and developments in medium and large-scale renewable power plant technologies, grid integration techniques and new converter topologies, including advanced digital control systems for medium-voltage networks. The book's individual chapters provide an extensive compilation of fundamental theories and in-depth information on current research and development trends, while also exploring new approaches to overcoming some critical limitations of conventional grid integration te

  7. Study and Experiment on Non-Contact Voltage Sensor Suitable for Three-Phase Transmission Line.

    Science.gov (United States)

    Zhou, Qiang; He, Wei; Xiao, Dongping; Li, Songnong; Zhou, Kongjun

    2015-12-30

    A voltage transformer, as voltage signal detection equipment, plays an important role in a power system. Presently, more and more electric power systems are adopting potential transformer and capacitance voltage transformers. Transformers are often large in volume and heavyweight, their insulation design is difficult, and an iron core or multi-grade capacitance voltage division structure is generally adopted. As a result, the detection accuracy of transformer is reduced, a huge phase difference exists between detection signal and voltage signal to be measured, and the detection signal cannot accurately and timely reflect the change of conductor voltage signal to be measured. By aiming at the current problems of electric transformation, based on electrostatic induction principle, this paper designed a non-contact voltage sensor and gained detection signal of the sensor through electrostatic coupling for the electric field generated by electric charges of the conductor to be measured. The insulation structure design of the sensor is simple and its volume is small; phase difference of sensor measurement is effectively reduced through optimization design of the electrode; and voltage division ratio and measurement accuracy are increased. The voltage sensor was tested on the experimental platform of simulating three-phase transmission line. According to the result, the designed non-contact voltage sensor can realize accurate and real-time measurement for the conductor voltage. It can be applied to online monitoring for the voltage of three-phase transmission line or three-phase distribution network line, which is in accordance with the development direction of the smart grid.

  8. Study and Experiment on Non-Contact Voltage Sensor Suitable for Three-Phase Transmission Line

    Directory of Open Access Journals (Sweden)

    Qiang Zhou

    2015-12-01

    Full Text Available A voltage transformer, as voltage signal detection equipment, plays an important role in a power system. Presently, more and more electric power systems are adopting potential transformer and capacitance voltage transformers. Transformers are often large in volume and heavyweight, their insulation design is difficult, and an iron core or multi-grade capacitance voltage division structure is generally adopted. As a result, the detection accuracy of transformer is reduced, a huge phase difference exists between detection signal and voltage signal to be measured, and the detection signal cannot accurately and timely reflect the change of conductor voltage signal to be measured. By aiming at the current problems of electric transformation, based on electrostatic induction principle, this paper designed a non-contact voltage sensor and gained detection signal of the sensor through electrostatic coupling for the electric field generated by electric charges of the conductor to be measured. The insulation structure design of the sensor is simple and its volume is small; phase difference of sensor measurement is effectively reduced through optimization design of the electrode; and voltage division ratio and measurement accuracy are increased. The voltage sensor was tested on the experimental platform of simulating three-phase transmission line. According to the result, the designed non-contact voltage sensor can realize accurate and real-time measurement for the conductor voltage. It can be applied to online monitoring for the voltage of three-phase transmission line or three-phase distribution network line, which is in accordance with the development direction of the smart grid.

  9. Harmonics and voltage stability analysis in power systems including ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    steady-state voltage stability analysis. 4. Harmonic power flow algorithm. Network voltages and currents can be expressed by Fourier series for the harmonic power flow analysis, which was developed by Xia & Heydt (1982). Voltages and nonlinear element parameters form the bus variable vector ( ), given in. [X] = [. [ ˙V (1). ] ...

  10. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2015-01-01

    of the proposed system is presented, and a dual voltage control strategy is then proposed, which comprises one voltage loop implemented in the synchronous reference frame for active power balancing, and another one implemented in the stationary reference frame for ripple power compensation. Special attention......The inherent double line ripple power in single-phase systems is adverse to the performance of power electronics converters, e.g. limited lifetime due to the requirement of large electrolytic capacitors and low voltage control bandwidth due to harmonic disturbance. In this paper, an active...... is given to the bandwidth of voltage control loops because the variation of dc-link voltage should be kept within an acceptable range during load transients. This is particularly important for systems with reduced dc-link capacitance because they are of lower energy capacity and the dc-link voltage...

  11. Management of Power Quality Issues in Low Voltage Networks using Electric Vehicles: Experimental Validation

    DEFF Research Database (Denmark)

    Martinenas, Sergejus; Knezovic, Katarina; Marinelli, Mattia

    2017-01-01

    the existing and future power quality problems. One of the main aspects of the power quality relates to voltage quality. The aim of this work is to experimentally analyse whether series-produced EVs, adhering to contemporary standard and without relying on any V2G capability, can mitigate line voltage drops...... in improving the power quality of a highly unbalanced grid......As Electric Vehicles (EVs) are becoming more wide spread, their high power consumption presents challenges for the residential low voltage networks, especially when connected to long feeders with unevenly distributed loads. However, if intelligently integrated, EVs can also partially solve...

  12. Calculations of lightning-induced voltages in medium voltage distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Munhoz Rojas, Patricio E. [Instituto de Tecnologia para o Desenvolvimento (LACTEC/UFPR), Curitiba, PR (Brazil)], E-mail: patricio@lactec.org.br; Pinto, Cleverson Luiz da Silva [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)], E-mail: cleverson@copel.com

    2007-07-01

    The objective of this paper is to show the results of a new computer program, written in Mat Lab environment, that is intended to calculate the lightning induced voltages in multi-conductor non-homogeneous lines, in order to be able to evaluate the impact of the usual protective measures implemented against lightning-induced disturbances. The main new features of this program are: a coupling model in terms of the scalar potentials referred to a remote ground was adopted; the coupling to the vertical conductors was considered in a manner similar to rest of the line; the describing equations were converted into a system of coupled ordinary differential equations, by a discretization only in space, which was subsequently solved using the powerful ODE solvers existing in Mat Lab. The validation of the new program has been performed by comparing its predicted results with other theoretical and computational results available in the literature and also with other experimental results published in the literature. It is shown that the agreement with other well established theoretical results is very good and, also, that the agreement between the newly calculated results and some published experimental results is better than previously obtained results. (author)

  13. Impact of the Voltage Dips in Shipboard Microgrid Power Systems

    DEFF Research Database (Denmark)

    Liu, Wenzhao; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    Voltage and frequency transient variations are the most common power quality issues in a ship microgrid system. In this paper, the impacts of the voltage dips induced by the sudden-load of ballast pump are analyzed in detail for the ship power systems. Several relevant ship power quality standards...

  14. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  15. Automatic Voltage Control (AVC) System under Uncertainty from Wind Power

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Flynn, Damian

    2016-01-01

    and constant in the decision making process. However, for high shares of wind power, uncertainty in the decision process due to wind power variability may result in an infeasible AVC solution. This paper proposes a voltage control approach which considers the voltage uncertainty from wind power productions....... The proposed method improves the performance and the robustness of a scenario based approach by estimating the potential voltage variations due to fluctuating wind power production, and introduces a voltage margin to protect the decision against uncertainty for each scenario. The effectiveness of the proposed...

  16. Research on the Temperature Field of High-Voltage High Power Line Start Permanent Magnet Synchronous Machines with Different Rotor Cage Structure

    Directory of Open Access Journals (Sweden)

    Zhaobin Cao

    2017-11-01

    Full Text Available For line start permanent magnet synchronous machines (LSPMSMs, the eddy current loss in the rotor, which has of significant effects on rotor working temperature, may cause thermal demagnetization to permanent magnet. Therefore, this paper addresses an investigation on the temperature distribution in LSPMSM based on a 6 kV, 315 kW prototype with solid starting cage bar. Firstly, the loss distributions, obtained from a 2-D transient electromagnetic field calculation, are determined as the distributed heat source in thermal analyses. Then, the fluid-thermal coupled analyses are performed, by which the temperature distributions in the machine are determined. Meanwhile, the calculated motor performance is verified via comparison with the measured results. The calculation results show that the temperatures in the rotor core and permanent magnets are relatively high. To find the solution for reducing the rotor working temperature, a rotor air slot structure was proposed in this analysis. The theoretical calculation indicates that the rotor working temperature reduction is obvious with the rotor air slot in the machine. Therefore, the operating situation of solid rotor LSPMSM could be improved effectively with the proposed rotor thermal solution, which also benefits the machine reliability and safety.

  17. Increasing Integration of Wind Power in Medium Voltage Grid by Voltage Support of Smart Transformer

    OpenAIRE

    Gao, Xiang; De Carne, Giovanni; Liserre, Marco; Vournas, Costas

    2016-01-01

    The voltage rise during wind energy penetration represents a limit of the wind power integration in the distribution grid. The Smart Transformer (ST), a power electronics-based transformer, can provide additional services to the distribution grids, for instance the voltage support in MV grid by means of reactive power injection. In this paper, this service is applied to increase the hosting capacity of wind power in MV grids.

  18. Real-time transient stabilization and voltage regulation of power generators with unknown mechanical power input

    Energy Technology Data Exchange (ETDEWEB)

    Kenne, Godpromesse, E-mail: gokenne@yahoo.co [Laboratoire d' Automatique et d' Informatique Appliquee (LAIA), Departement de Genie Electrique, Universite de Dschang, B.P. 134 Bandjoun (Cameroon); Goma, Raphael, E-mail: raphael.goma@lss.supelec.f [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Nkwawo, Homere, E-mail: homere.nkwawo@iutv.univ-paris13.f [Departement GEII, Universite Paris XIII, 99 Avenue Jean Baptiste Clement, 93430 Villetaneuse (France); Lamnabhi-Lagarrigue, Francoise, E-mail: lamnabhi@lss.supelec.f [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Arzande, Amir, E-mail: Amir.arzande@supelec.f [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Vannier, Jean Claude, E-mail: Jean-claude.vannier@supelec.f [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France)

    2010-01-15

    A nonlinear adaptive excitation controller is proposed to enhance the transient stability and voltage regulation of synchronous generators with unknown power angle and mechanical power input. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of relative angular speed, active electric power, infinite bus and generator terminal voltages. The operating conditions are computed online using the above physical available measurements, the terminal voltage reference value and the estimate of the mechanical power input. The proposed design is therefore capable of providing satisfactory voltage in the presence of unknown variations of the power system operating conditions. Using the concept of sliding mode equivalent control techniques, a robust decentralized adaptive controller which insures the exponential convergence of the outputs to the desired ones, is obtained. Real-time experimental results are reported, comparing the performance of the proposed adaptive nonlinear control scheme to one of the conventional AVR/PSS controller. The high simplicity of the overall adaptive control scheme and its robustness with respect to line impedance variation including critical unbalanced operating condition and temporary turbine fault, constitute the main positive features of the proposed approach.

  19. Multi-Objective Differential Evolution for Voltage Security Constrained Optimal Power Flow in Deregulated Power Systems

    Science.gov (United States)

    Roselyn, J. Preetha; Devaraj, D.; Dash, Subhransu Sekhar

    2013-11-01

    Voltage stability is an important issue in the planning and operation of deregulated power systems. The voltage stability problems is a most challenging one for the system operators in deregulated power systems because of the intense use of transmission line capabilities and poor regulation in market environment. This article addresses the congestion management problem avoiding offline transmission capacity limits related to voltage stability by considering Voltage Security Constrained Optimal Power Flow (VSCOPF) problem in deregulated environment. This article presents the application of Multi Objective Differential Evolution (MODE) algorithm to solve the VSCOPF problem in new competitive power systems. The maximum of L-index of the load buses is taken as the indicator of voltage stability and is incorporated in the Optimal Power Flow (OPF) problem. The proposed method in hybrid power market which also gives solutions to voltage stability problems by considering the generation rescheduling cost and load shedding cost which relieves the congestion problem in deregulated environment. The buses for load shedding are selected based on the minimum eigen value of Jacobian with respect to the load shed. In the proposed approach, real power settings of generators in base case and contingency cases, generator bus voltage magnitudes, real and reactive power demands of selected load buses using sensitivity analysis are taken as the control variables and are represented as the combination of floating point numbers and integers. DE/randSF/1/bin strategy scheme of differential evolution with self-tuned parameter which employs binomial crossover and difference vector based mutation is used for the VSCOPF problem. A fuzzy based mechanism is employed to get the best compromise solution from the pareto front to aid the decision maker. The proposed VSCOPF planning model is implemented on IEEE 30-bus system, IEEE 57 bus practical system and IEEE 118 bus system. The pareto optimal

  20. EVALUATING DEGREE OF ACTIVE POWER LOSSES REDUCTION IN THE ELECTRIC POWER LINES WITH REACTIVE POWER COMPENSATION

    Directory of Open Access Journals (Sweden)

    V. N. Radkevich

    2016-01-01

    Full Text Available The paper considers evaluation procedure for the degree of active power losses reduction in the power transmission lines under 1 kV and 6–10 kV of the systems of electric power supply of industrial enterprises with compensating installations mounted at the side of the customer. The capacitor installations conform to the applied voltage level and factor in dielectric losses in the capacitors. The voltage at the compensating device terminal changes from 0.95 to 1.05 of the capacitors nominal voltage. The study did not account for reactive power losses in the line, nor did it for its charge capacity, conditioned by relative shortness of the cable lines generally operating in the mains of industrial enterprises. For this reason, the quantities of reactive power being consumed and generated by the transmission line are negligible and do not significantly affect the reactive power flux. The researchers obtain functional relations that allow estimating the degree of power loss reduction in the transmission line factoring in its explicit initial data. They perform mathematical analysis of the obtained functional relations and study the function by means of derivatives. The function extremum points are found as well as the intervals of its increment and decrement. A graphical research of the obtained functional relation is performed. It is ascertained that reduction of the active power losses is contingent on the line and the capacitor-installation engineering factors, the electrical energy consumer reactive load value as well as the voltage applied to the capacitor installation. The functional relations presented in the article can be employed in scoping calculation necessary for decision making on the reactive power compensation in systems of the industrial facilities electric power supply. Their account will allow a more accurate estimate of technical and economic effect of the capacitor bank installation in the electrical mains under 1 kV and 6

  1. Reliability Evaluation of Power System Considering Voltage Stability and Continuation Power Flow

    Directory of Open Access Journals (Sweden)

    R. K. Saket

    2007-06-01

    Full Text Available This article describes the methodology for evaluation of the reliability of an composite electrical power system considering voltage stability and continuation power flow, which takes into account the peak load and steady state stability limit. The voltage stability is obtained for the probable outage of transmission lines and removal of generators along with the combined state probabilities. The loss of load probabilities (LOLP index is evaluated by merging the capacity probability with load model. State space is truncated by assuming the limits on total numbers of outages of generators and transmission lines. A prediction correction technique has been used along with one dimensional search method to get optimized stability limit for each outage states. The algorithm has been implemented on a six-bus test system.

  2. Impact of Wind Power Plants on Voltage Control of Power System

    DEFF Research Database (Denmark)

    Sarkar, Moumita; Altin, Müfit; Hansen, Anca Daniela

    High penetration of renewable energy sources poses numerous challenges on stability and security of power systems. Wind power plants (WPPs) of considerable size when connected to a weak grid by long transmission line results in low short circuit ratio at the point of connection. This may result i...... control, during transient voltage dips. Steady-state analysis is performed for stressed system conditions. Results are validated through simulation in a detailed power system model.......High penetration of renewable energy sources poses numerous challenges on stability and security of power systems. Wind power plants (WPPs) of considerable size when connected to a weak grid by long transmission line results in low short circuit ratio at the point of connection. This may result...

  3. Electrical engineering unit for the reactive power control of the load bus at the voltage instability

    Science.gov (United States)

    Kotenev, A. V.; Kotenev, V. I.; Kochetkov, V. V.; Elkin, D. A.

    2018-01-01

    For the purpose of reactive power control error reduction and decrease of the voltage sags in the electric power system caused by the asynchronous motors started the mathematical model of the load bus was developed. The model was built up of the sub-models of the following elements: a transformer, a transmission line, a synchronous and an asynchronous loads and a capacitor bank load, and represents the automatic reactive power control system taking into account electromagnetic processes of the asynchronous motors started and reactive power changing of the electric power system elements caused by the voltage fluctuation. The active power/time and reactive power/time characteristics based on the recommended procedure of the equivalent electric circuit parameters calculation were obtained. The derived automatic reactive power control system was shown to eliminate the voltage sags in the electric power system caused by the asynchronous motors started.

  4. Unique Power Dense, Configurable, Robust, High-Voltage Power Supplies Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Princeton Power will develop and deliver three small, lightweight 50 W high-voltage power supplies that have a configurable output voltage range from 500 to 50 kVDC....

  5. Fast voltage stability assessment for large-scale power systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y. [Shandong Univ., Jinan (China). School of Electrical Engineering; Wang, L.; Yu, Z. [Shandong Electric Power Co., Jinan (China). Electric Power Control Center

    2007-07-01

    A new method of assessing online voltage stability in large-scale power systems was presented. A local voltage stability index was used to determine weak buses in the system. A case study of the Shandong power system in China was used to demonstrate the accuracy and speed of the method for online applications. The local method was based on the fact that the Thevenin equivalent as determined from the load bus and the apparent load impedance were equal at the point of voltage collapse. Participant buses and key power sources of both reactive and active power transmission paths were determined using electrical distance measurements. Participant buses and key power sources of the reactive and active power transmission paths were also determined. The case study demonstrated that the reactive power reserve of key generators has a significant impact on voltage stability. The study also demonstrated that the voltage stability of the weakest power transmission path can decline or shift when some generators reach their limits. It was concluded that combining voltage stability indices and reactive power reserves increases the accuracy of voltage stability assessments. 11 refs., 3 tabs., 6 figs.

  6. Low power, high voltage power supply with fast rise/fall time

    Science.gov (United States)

    Bearden, Douglas B. (Inventor)

    2007-01-01

    A low power, high voltage power supply system includes a high voltage power supply stage and a preregulator for programming the power supply stage so as to produce an output voltage which is a predetermined fraction of a desired voltage level. The power supply stage includes a high voltage, voltage doubler stage connected to receive the output voltage from the preregulator and for, when activated, providing amplification of the output voltage to the desired voltage level. A first feedback loop is connected between the output of the preregulator and an input of the preregulator while a second feedback loop is connected between the output of the power supply stage and the input of the preregulator.

  7. On-line Dynamic Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel

    angular divergence of a group of generators can cause critical voltage sags at certain buses in the system. In this thesis assessment of such voltage sags using two types of sensitivities, which are derived from the algebraic network equations, is proposed. These sensitivities are derived after an in......-depth study of the mechanism causing the voltage sags. The first sensitivity type is called load voltage i/xii sensitivity and allows identifying which bus voltages are affected by a change in rotor angle of a particular generator. The second proposed type is called generator power sensitivity, which provides...... for early prediction of critical voltage sags is described. The method’s performance is compared to other prediction approaches. The results show that the proposed method succeeds in early, accurately and consistently predicting critically low voltage sags. An efficient on-line DSA not only identifies...

  8. A dual voltage control strategy for single-phase PWM converters with power decoupling function

    DEFF Research Database (Denmark)

    Tang, Yi; Qin, Zian; Blaabjerg, Frede

    2014-01-01

    is presented, and a dual voltage control strategy is then proposed, which comprises one voltage loop implemented in the synchronous reference frame for active power balancing, and another one implemented in the harmonic reference frame for ripple power compensation. Special attention is given to the bandwidth......The inherent double line ripple power in singlephase systems is adverse to the converter performance, e.g. limited lifetime due to the requirement of large electrolytic capacitors and low voltage control bandwidth due to harmonic disturbance. In this paper, an active converter topology based...... of voltage control loop because the variation of dc-link voltage should be kept within an acceptable range during load transients. This is particularly important for systems with reduced dc-link capacitance because they are of lower energy capacity and very sensitive to step load changes. Simulation results...

  9. Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal

    KAUST Repository

    Kim, Younggy

    2011-01-01

    Voltages produced by microbial fuel cells (MFCs) cannot be sustainably increased by linking them in series due to voltage reversal, which substantially reduces stack voltages. It was shown here that MFC voltages can be increased with continuous power production using an electronic circuit containing two sets of multiple capacitors that were alternately charged and discharged (every one second). Capacitors were charged in parallel by the MFCs, but linked in series while discharging to the circuit load (resistor). The parallel charging of the capacitors avoided voltage reversal, while discharging the capacitors in series produced up to 2.5 V with four capacitors. There were negligible energy losses in the circuit compared to 20-40% losses typically obtained with MFCs using DC-DC converters to increase voltage. Coulombic efficiencies were 67% when power was generated via four capacitors, compared to only 38% when individual MFCs were operated with a fixed resistance of 250 Ω. The maximum power produced using the capacitors was not adversely affected by variable performance of the MFCs, showing that power generation can be maintained even if individual MFCs perform differently. Longer capacitor charging and discharging cycles of up to 4 min maintained the average power but increased peak power by up to 2.6 times. These results show that capacitors can be used to easily obtain higher voltages from MFCs, allowing for more useful capture of energy from arrays of MFCs. © 2011 The Royal Society of Chemistry.

  10. Insulation co-ordination in high-voltage electric power systems

    CERN Document Server

    Diesendorf, W

    2015-01-01

    Insulation Co-ordination in High-Voltage Electric Power Systems deals with the methods of insulation needed in different circumstances. The book covers topics such as overvoltages and lightning surges; disruptive discharge and withstand voltages; self-restoring and non-self-restoring insulation; lightning overvoltages on transmission lines; and the attenuation and distortion of lightning surges. Also covered in the book are topics such as the switching surge designs of transmission lines, as well as the insulation coordination of high-voltage stations. The text is recommended for electrical en

  11. High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

    Science.gov (United States)

    Bozak, Karin E.; Pinero, Luis R.; Scheidegger, Robert J.; Aulisio, Michael V.; Gonzalez, Marcelo C.; Birchenough, Arthur G.

    2015-01-01

    A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources - a nominal 300-Volt high voltage input bus and a nominal 28-Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power supplies that provide power to the thruster auxiliary supplies, and two parallel 7.5 kilowatt power supplies that are capable of providing up to 15 kilowatts of total power at 300-Volts to 500-Volts to the thruster discharge supply. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall Effect Thruster. The performance of unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate the exceptional performance with full power efficiencies exceeding 97. With a space-qualified silicon carbide or similar high voltage, high efficiency power device, this design could evolve into a flight design for future missions that require high power electric propulsion systems.

  12. Power flow analysis for DC voltage droop controlled DC microgrids

    DEFF Research Database (Denmark)

    Li, Chendan; Chaudhary, Sanjay; Dragicevic, Tomislav

    2014-01-01

    This paper proposes a new algorithm for power flow analysis in droop controlled DC microgrids. By considering the droop control in the power flow analysis for the DC microgrid, when compared with traditional methods, more accurate analysis results can be obtained. The algorithm verification...... is carried out by comparing the calculation results with detailed time domain simulation results. With the droop parameters as variables in the power flow analysis, their effects on power sharing and secondary voltage regulation can now be analytically studied, and specialized optimization in the upper level...... control can also be made accordingly. Case studies on power sharing and secondary voltage regulation are carried out using proposed power flow analysis....

  13. High Input Voltage, Silicon Carbide Power Processing Unit Performance Demonstration

    Science.gov (United States)

    Bozak, Karin E.; Pinero, Luis R.; Scheidegger, Robert J.; Aulisio, Michael V.; Gonzalez, Marcelo C.; Birchenough, Arthur G.

    2015-01-01

    A silicon carbide brassboard power processing unit has been developed by the NASA Glenn Research Center in Cleveland, Ohio. The power processing unit operates from two sources: a nominal 300 Volt high voltage input bus and a nominal 28 Volt low voltage input bus. The design of the power processing unit includes four low voltage, low power auxiliary supplies, and two parallel 7.5 kilowatt (kW) discharge power supplies that are capable of providing up to 15 kilowatts of total power at 300 to 500 Volts (V) to the thruster. Additionally, the unit contains a housekeeping supply, high voltage input filter, low voltage input filter, and master control board, such that the complete brassboard unit is capable of operating a 12.5 kilowatt Hall effect thruster. The performance of the unit was characterized under both ambient and thermal vacuum test conditions, and the results demonstrate exceptional performance with full power efficiencies exceeding 97%. The unit was also tested with a 12.5kW Hall effect thruster to verify compatibility and output filter specifications. With space-qualified silicon carbide or similar high voltage, high efficiency power devices, this would provide a design solution to address the need for high power electric propulsion systems.

  14. Distance protection of multiple-circuit shared tower transmission lines with different voltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. In this study, the fault loop impedance of combined faults is compared with the fault loop impedance......-phase-to-ground faults. It is also demonstrated that the fault loop impedance of combined faults is more resistive, when compared with equivalent single-phase-to-ground faults. It is concluded that the settings used to protect a line against single-phase-to-ground faults are capable of protecting the line against...... of single-phase-to-ground faults and it is demonstrated that they are similar for high short-circuit powers; however, the fault loop impedance of a combined fault may increase substantially as the short-circuit power of the system decreases, a behaviour that is less noticeable for single...

  15. Eliminating harmonics in line to line voltage using genetic algorithm using multilevel inverter

    Energy Technology Data Exchange (ETDEWEB)

    Gunasekaran, R. [Excel College of Engineering and Technology, Komarapalayam (India). Electrical and Electronics Engineering; Karthikeyan, C. [K.S. Rangasamy College of Engineering, Tamil Nadu (India). Electrical and Electronics Engineering

    2017-04-15

    In this project the total harmonic distortion (THD) minimization of the multilevel inverters output voltage is discussed. The approach in reducing harmonics contents in inverters output voltage is THD elimination. The switching angles are varied with the fundamental frequency so the output THD is minimized. In three phase applications, the line voltage harmonics are of the main concern from the load point of view. Using a genetic algorithm, a THD minimization process is directly applied to the line to line voltage of the inverter. Genetic (GA) algorithm allows the determination of the optimized parameters and consequently an optimal operating point of the circuit and a wide pass band with a unity gain is obtained.

  16. Voltage Control in Distribution Systems Considered Reactive Power Output Sharing

    Science.gov (United States)

    Oshiro, Masato; Senjyu, Tomonobu; Yona, Atsushi; Urasaki, Naomitsu; Funabashi, Toshihisa

    In recent years, distributed generation (DG) and renewable energy source (RES) are attracting special attention to distribution systems. Renewable energy such as photovoltaic (PV) system and wind turbine generator are used as a source of clean energy. However, the large amount of distributed generation causes voltage deviation beyond a statutory range in distribution systems. This paper proposes a methodology for voltage control by using inverters interfaced with DG and tap changing transformers. In the proposed method a one-day schedule of voltage references for the control devices are determined by an optimization technique based on predicted values of load demand and PV power generation. Furthermore, decided reactive power output according to the locally measurable voltage based on droop characteristic. Slope and base value on droop characteristic are selected by fuzzy control. The proposed method accomplishes improvement against voltage distribution considered the reactive power output sharing and reduction of distribution loss. The effectiveness of the proposed method is verified by using MATLAB®.

  17. A Grid Voltage Measurement Method for Wind Power Systems during Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Cheol-Hee Yoo

    2014-11-01

    Full Text Available Grid codes in many countries require low-voltage ride-through (LVRT capability to maintain power system stability and reliability during grid fault conditions. To meet the LVRT requirement, wind power systems must stay connected to the grid and also supply reactive currents to the grid to support the recovery from fault voltages. This paper presents a new fault detection method and inverter control scheme to improve the LVRT capability for full-scale permanent magnet synchronous generator (PMSG wind power systems. Fast fault detection can help the wind power systems maintain the DC-link voltage in a safe region. The proposed fault detection method is based on on-line adaptive parameter estimation. The performance of the proposed method is verified in comparison to the conventional voltage measurement method defined in the IEC 61400-21 standard.

  18. Self-monitoring high voltage transmission line suspension insulator

    Science.gov (United States)

    Stemler, Gary E.; Scott, Donald N.

    1981-01-01

    A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

  19. Electromagnetic field calculation for 110 kV power line

    Directory of Open Access Journals (Sweden)

    Berzan V.

    2015-08-01

    Full Text Available The paper studies the evolution of values for the characteristic electric field and magnetic field generated by power line voltages and currents voltage 110 kV their value based snapshots. These evolutions we examined in changing the value of the angle of the voltage vector and current vector within 0o...180o. The conductors are placed horizontally and triangle tops with different lengths of the sides. The electric field distribution was calculated with finite volume method. Since the electric field distributions were determined parameter values of LEA110 kV. The values of the line parameters, which were determined by the finite volume method, difference from the values calculated by the traditional method. In this context finite volume method presents attractive enough to determine the parameters of power lines and spatial distribution of the electric field in three-phase lines.

  20. Voltage stability margins assessment for Muscat power system

    Energy Technology Data Exchange (ETDEWEB)

    Ellithy, K.A.; Gastli, A. [Sultan Qaboos Univ., Dept. of Electrical Engineering and Electronics, Muscat (Oman); Al-Khusaibi, T. [Ministry of Housing and Electricity and Water, Muscat (Oman); Irving, M. [Brunel Univ., Dept. of Electrical Engineering and Electronics, Uxbridge (United Kingdom)

    2002-10-01

    Voltage instability problems in power systems today are, in many countries, one of the major concerns in power system planning and operation. This paper presents the assessment of voltage stability margins for Muscat power system under normal operating condition and under contingencies. The modal analysis method is applied to identify the weak buses in the system, which could lead to voltage instability. These weak buses are selected as the best locations for applying remedial actions to enhance the stability margins. The results show that the buses at South Batna load area are the weakest buses in the system. The results also show that an increase in load demand on that area without an adequate increase of reactive power could lead to voltage collapse. Shunt VAR compensations (remedial action) are installed at the weakest buses to enhance the system stability margins. The results presented in this paper are obtained using a MATLAB computer program developed by the authors. (Author)

  1. Design and development of high voltage high power operational ...

    Indian Academy of Sciences (India)

    Normally power opamps can deliver current more than 50 mA and can operate on the supply voltage more than ±25 V. This paper gives the details of one of the power opamps developed to drive the Piezo Actuators for Active Vibration Control (AVC) of aircraft/aerospace structures. The designed power opamp will work on ...

  2. Reliability and Characterization of High Voltage Power Capacitors

    Science.gov (United States)

    2014-03-01

    permittivity EVCS electric vehicle charging system GPIB general-purpose interface bus GW giga-watt HVST high voltage stress test IV current voltage...traditional fossil fuel . The typical solar power system requires multiple subsystems as well as the physical infrastructure to support the solar panels. The...that will last, reducing the militaries overall dependence on traditional fossil fuel . B. CONVERTER OVERVIEW The typical solar power system

  3. Mitigation of voltage dip and power system oscillations damping using dual STATCOM for grid connected DFIG

    Directory of Open Access Journals (Sweden)

    D.V.N. Ananth

    2017-12-01

    Full Text Available During grid fault, transmission lines reach its thermal limit and lose its capability to transfer. If this fault current enters generator terminals, it will lead to dip in stator voltage and consequently produces torque and real power oscillations. This further affects in the form of internal heat in rotor windings and finally damages the generator. A new control strategy is proposed to limit fault current using dual STATCOM, which will damp power oscillations and mitigate the voltage dip due to a severe symmetrical fault. It is achieved by diverting the fault current to the capacitor using the dual-STATCOM controller. It is best suitable to maintain power system stability with uninterrupted power supply, effective power transfer capability and rapid reactive power support and to damp inter-area oscillations. The effectiveness of SG and DFIG due to the transmission line short circuit symmetrical fault was studied.

  4. 30 CFR 77.704-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 77.704-1 Section 77... MINES Grounding § 77.704-1 Work on high-voltage lines. (a) No high-voltage line shall be regarded as... provided in § 77.103) that such high-voltage line has been deenergized and grounded. Such qualified person...

  5. Temperature Stabilized Characterization of High Voltage Power Supplies

    CERN Document Server

    Krarup, Ole

    2017-01-01

    High precision measurements of the masses of nuclear ions in the ISOLTRAP experiment relies on an MR-ToF. A major source of noise and drift is the instability of the high voltage power supplies employed. Electrical noise and temperature changes can broaden peaks in time-of-flight spectra and shift the position of peaks between runs. In this report we investigate how the noise and drift of high-voltage power supplies can be characterized. Results indicate that analog power supplies generally have better relative stability than digitally controlled ones, and that the high temperature coefficients of all power supplies merit efforts to stabilize them.

  6. 76 FR 19698 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-04-08

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Repair of High Voltage Transmission Lines..., within the Captain of the Port (COTP) Boston Zone to allow for repair of high voltage transmission lines... during the repair of high voltage transmission lines. Entering into, transiting through, mooring or...

  7. 76 FR 4575 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-01-26

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AAOO Safety Zone; Repair of High Voltage Transmission Lines... of high voltage transmission lines to Logan Airport. This safety zone is required to provide for the safety of life on navigable waters during the repair of high voltage transmission lines. Entering into...

  8. 30 CFR 75.705-1 - Work on high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines. 75.705-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.705-1 Work on high-voltage lines. (a) Section 75.705 specifically prohibits work on energized high-voltage lines underground; (b...

  9. Analysis of harmonics in the power supply networks of electric welding equipment of alternating voltage

    Directory of Open Access Journals (Sweden)

    Василь Ількович Гудим

    2015-11-01

    Full Text Available Electric arc welding is widely used in construction and engineering for rigid connections of metal elements. Substantial nonlinearity of dynamic voltage-current characteristics of electric arcs in such equipment is a source of distortion in current and voltage sinusoids at the points of other electric receivers parallel joints. The voltage fluctuations from the nominal value result in changing luminous flux of bulbs, while current higher harmonics result in additional losses in electric motors. However, the problem of electric welding equipment influence on power lines wasn’t paid proper attention to. Therefore, this work is to research electric arc equipment influence on power lines in order to find out the values and the spectrum of higher harmonics, and the prevailing amplitudes dynamics of change. In this paper the results of experimental researches of harmonics spectrum in electrical circuits of electric arc welding machine of alternating voltage that it generates during the technological process and the main energy parameters, that influence negatively on the power supply networks of 0,4/0,23 kV. Analyzing the results of the measurements we come to the conclusion that if the load factor is about 35% the power coefficient of the welding machine is 0,46, that is rather low. Such a result is economically disadvantageous since high reactive power results in a significant increase of active power losses in the elements of power supply. That’s why reactive power compensation as well as higher harmonics filtration are necessitated

  10. Understanding broadband over power line

    CERN Document Server

    Held, Gilbert

    2006-01-01

    Understanding Broadband over Power Line explores all aspects of the emerging technology that enables electric utilities to provide support for high-speed data communications via their power infrastructure. This book examines the two methods used to connect consumers and businesses to the Internet through the utility infrastructure: the existing electrical wiring of a home or office; and a wireless local area network (WLAN) access point.Written in a practical style that can be understood by network engineers and non-technologists alike, this volume offers tutorials on electric utility infrastru

  11. A comparative study of different transformer connections for railway power supply- mitigation of voltage unbalance

    DEFF Research Database (Denmark)

    Firat, Gurkan; Yang, Guangya; Ali Hussain Al-Ali, Haider

    2015-01-01

    that, voltage unbalance appears mainly as a result of unbalanced currents at the points of common coupling drawn by unevenly distributed loads. Because of a significant amount of negative sequence current injected to the system, the power system components will suffer from consequent negative effects...... such as overheating, additional losses of lines and transformers, interference with communication systems etc. This paper presents a comparative study of some transformer connections which commonly used in railway supplying AC traction loads, for voltage unbalance mitigations. Simulations for comparison...... of transformers are carried out and the results are also compared with the values obtained by the voltage unbalance estimation formulas....

  12. Local Dynamic Reactive Power for Correction of System Voltage Problems

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

    2008-12-01

    Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results

  13. Convex Relaxation of Power Dispatch for Voltage Stability Improvement

    DEFF Research Database (Denmark)

    Pedersen, Andreas Søndergaard; Blanke, Mogens; Jóhannsson, Hjörtur

    2015-01-01

    A method for enhancing the voltage stability ofa power system is presented in this paper. The method isbased on a stability-constrained optimal power flow approach,where dispatch is done such that a maximum L-index isminimised for all load busses in a transmission grid. It isshown that optimal...... dispatch is obtainable with enhancedmargins for voltage stability using a semidefinite relaxation ofthe optimal power flow problem, and that this problem canbe formulated as semidefinite program with a quasi-convexobjective. Numerical tests are performed on the IEEE-30 busand BPA systems. The feasibility...

  14. Design and development of high voltage high power operational ...

    Indian Academy of Sciences (India)

    systems and the electron deflection systems. Power operational amplifiers have ... approach is cost and availability of high voltage devices in chip form. 2.2 Amplifier with opamp input stage .... power opamp, using chip passive components, semiconductor bare dice minimizes the size while increasing the reliability.

  15. Harmonics and voltage stability analysis in power systems including ...

    Indian Academy of Sciences (India)

    In this study, non-sinusoidal quantities and voltage stability, both known as power quality criteria, are examined together in detail. The widespread use of power electronics elements cause the existence of significant non-sinusoidal quantities in the system. These non-sinusoidal quantities can create serious harmonic ...

  16. Low Power/Low Voltage Interface Circuitry for Capacitive Sensors

    DEFF Research Database (Denmark)

    Furst, Claus Efdmann

    consumption of different amplifier topologies. Next, low power features of different amplifier types are analyzed on transistor level. A brief comparison of SI circuits for low power applications vs. SC circuits is presented. Methodologies for low voltage design is presented. This is followed by a collection...

  17. Assessing Losses of Power and Electrical Energy in Unbalanced Medium Voltage Distribution Networks

    Directory of Open Access Journals (Sweden)

    Toader C.

    2016-12-01

    Full Text Available The work is dedicated to calculating electricity losses related to power lines average voltage overhead or underground, which in terms of construction can be three-phase (three or four wire in unbalanced sinusoidal harmonic, determining energy efficiency indicators (such as positive and negative factors of unbalance thereof. It examines a case study and argues the results.

  18. Analysis and modeling of low voltage electrical network at power line carrier frequencies (3-148.5 kHz); Analyse et modelisation du reseau basse tension aux frequences courants porteurs (3 KHZ-148,5 KHZ)

    Energy Technology Data Exchange (ETDEWEB)

    Duval, G.

    1998-07-01

    Electricite de France (EdF) wishes to establish a physical communication link between his clients and the EdF centres. The final link, i.e. between the high/low voltage transformation substation and the residential clients, being ensured by carrier currents. With this aim, an analysis and a modeling of the low voltage network at the carrier frequencies (3 kHz - 148.5 kHz) has been performed. This work has been carried out in parallel with an experiment involving 3500 apparatuses that use carrier currents. The diversity of the French low voltage networks and the limitations imposed by the EN50065-1 standard about the use of carrier currents in Europe do not favour the development of such carrier current systems. Disturbing voltages and localized impedances represent the main difficulties to get round. Inside accommodations, domotic carrier currents have a reduced range but a higher disturbance amplitude because of the proximity of appliances. A differential mode to common mode conversion phenomenon has been evidenced which generates network couplings and important electromagnetic fields. Energy lines and cables have been analyzed using numerical models. Load peaks have been analyzed using statistical tools in order to take into account the daily fluctuations. The modeling of the network is made in two steps: a double-wire model is considered first. Then a three-phase model is developed which analyzes the inter-phases coupling and the effect of the distribution of clients' loads on each phase. The results of this model are conformable with measurements except for underground networks. As perspectives of future works and beyond todays standard framework, the techniques that allow a sensible increase of communication flow rates have been reviewed. (J.S.)

  19. Voltage Harmonics Mitigation through Hybrid Active Power Filter

    Directory of Open Access Journals (Sweden)

    Anwer Ali Sahito

    2016-01-01

    Full Text Available Fast dynamic response, high efficiency, low cost and small size of power electronic converters have exponentially increased their use in modern power system which resulted in harmonically distorted voltage and currents. Voltage harmonics mainly caused by current harmonics are more dangerous as performance and expected operating life of other power system equipment are affected by harmonically distorted supply voltage. Electronic filter circuits are used to improve system power quality by mitigating adverse effects of harmonics. Hybrid filters having advantages of both passive and active filters are preferred to resolve the problem of harmonics efficiently and avoiding any chance of resonance. In this paper, a three phase three wire network is considered to supply an adjustable speed drive represented by a resistive load connected across a three phase bridge rectifier. Simulation of the considered system shows THD (Total Harmonic Distortion of 18.91 and 7.61% in supply current and voltage respectively. A HAPF (Hybrid Active Power Filter is proposed to reduce these THD values below 5% as recommended by IEEE Standard-519. P-Q theorem is used to calculate required parameters for proposed filter, which is implemented through hysteresis control. Simulation results confirm the effectiveness of the designed filter as THD for both current and voltage have reduced below allowable limit of 5%.

  20. An Optimized Reactive Power Control of Distributed Solar Inverters in Low Voltage Networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2011-01-01

    This study examines the reactive power ancillary services of solar inverters which are connected to low voltage (LV) distribution networks by giving attention to the grid voltage support service and grid losses. Two typical reference LV distribution network models as suburban and farm...... are introduced from the literature in order to evaluate contribution of two static droop strategies cosφ(P) and Q(U) on the grid voltage. Photovoltaic (PV) hosting capacities of the suburban and farm networks are estimated and the most predominant limitations of connecting more solar inverters are emphasized...... for each network type. Regarding the overloading of MV/LV distribution transformers, overloading of lines and the grid overvoltage limitations, new local grid voltage support methods (cosφ(P,U) and Q(U,P)) are also proposed. Resulting maximum allowable penetration levels with different reactive power...

  1. High Voltage Power Supply With High Output Current and Low Power Consumption for Photomultiplier Tubes

    Science.gov (United States)

    Cunha, José Paulo V. S.; Begalli, Marcia; Bellar, Maria Dias

    2012-04-01

    In some applications, photomultiplier tubes (PMTs) are powered by battery based circuits, where the available energy is severely limited. The most simple approach to design high voltage power supplies (HVPS) for PMTs has considered resistive voltage dividers in order to bias the dynodes. However, this approach usually results in high power losses and, consequently, this undermines the PMT performance. In this work, the proposed solution is the use of a power circuit based on the forward converter connected to a transformer built with several secondary windings. Each secondary voltage is rectified and filtered to eliminate voltage ripple. Each dynode voltage is supplied by a rectified secondary voltage. The proposed topology provides low power consumption as well as low sensitivity of the PMT gain with respect to the dynode currents. Taking into account the Waste Electrical and Electronic Equipment Directive (WEEE), this HVPS has been designed to allow the recycling of old PMTs.

  2. Analysis of Programmable Voltage Source under Power Supply Interference

    Directory of Open Access Journals (Sweden)

    Sheroz Khan

    2008-09-01

    Full Text Available A programmable voltage source is designed by programming a microcontroller making it capable to generate a digital output which is harnessed to ultimately control a voltage to a desirable level. This paper examines the effects of power supply interference on this source by firstly, introducing noise into the power supply of a microcontroller and secondly, introducing noise into the power supply of the operational amplifiers. The effect of the noise on the output voltage source is examined and the resultant error is analyzed and shown theoretically and experimentally to be proportional with the magnitude of the noise and dependent on the harmonic components of the interference signal. The PIC16F877A microcontroller is used in the experimental analysis to verify the theoretical explanations.

  3. Steady State Analysis of a UPFC as Voltage Regulator for Optimal Position in the Transmission Line

    Directory of Open Access Journals (Sweden)

    S. Ali Al-Mawsawi

    2003-06-01

    Full Text Available It has recently been illustrated that the Unified Power Flow Controller (UPFC installation location plays an important role in effecting nonlinearly in the UPFC steady state performance of the system. A Pulse Width Modulation (PWM based on UPFC as a voltage regulator is modeled and analyzed to investigate the optimal position in the transmission line. From the study made in this paper, it is shown that the location of UPFC plays a significant part in effecting nonlinearly. It is also found from the simulation results that the distribution of the active and reactive power flows can be controlled by varying the modulation index of the device.

  4. 30 CFR 77.807-2 - Booms and masts; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ...-voltage lines. 77.807-2 Section 77.807-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-2 Booms and masts; minimum distance from high-voltage lines. The booms and masts of equipment operated on the surface of any...

  5. 30 CFR 77.807-3 - Movement of equipment; minimum distance from high-voltage lines.

    Science.gov (United States)

    2010-07-01

    ... high-voltage lines. 77.807-3 Section 77.807-3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.807-3 Movement of equipment; minimum distance from high-voltage lines. When any part of any equipment operated on the surface of any...

  6. Distributed Reactive Power Control based Conservation Voltage Reduction in Active Distribution Systems

    Directory of Open Access Journals (Sweden)

    EMIROGLU, S.

    2017-11-01

    Full Text Available This paper proposes a distributed reactive power control based approach to deploy Volt/VAr optimization (VVO / Conservation Voltage Reduction (CVR algorithm in a distribution network with distributed generations (DG units and distribution static synchronous compensators (D-STATCOM. A three-phase VVO/CVR problem is formulated and the reactive power references of D-STATCOMs and DGs are determined in a distributed way by decomposing the VVO/CVR problem into voltage and reactive power control. The main purpose is to determine the coordination between voltage regulator (VR and reactive power sources (Capacitors, D-STATCOMs and DGs based on VVO/CVR. The study shows that the reactive power injection capability of DG units may play an important role in VVO/CVR. In addition, it is shown that the coordination of VR and reactive power sources does not only save more energy and power but also reduces the power losses. Moreover, the proposed VVO/CVR algorithm reduces the computational burden and finds fast solutions. To illustrate the effectiveness of the proposed method, the VVO/CVR is performed on the IEEE 13-node test system feeder considering unbalanced loading and line configurations. The tests are performed taking the practical voltage-dependent load modeling and different customer types into consideration to improve accuracy.

  7. Smart street lights using power line communication

    CSIR Research Space (South Africa)

    Du Toit, P

    2017-09-01

    Full Text Available street light faults with the use of communication over the power line. The developed system communicates over power lines using modified frequency shift keying (FSK) modulation. The system used an LDR (light dependent resistor) based light sensor...

  8. Line Capacity Expansion and Transmission Switching in Power Systems With Large-Scale Wind Power

    DEFF Research Database (Denmark)

    Villumsen, Jonas Christoffer; Bronmo, Geir; Philpott, Andy B.

    2013-01-01

    In 2020 electricity production from wind power should constitute nearly 50% of electricity demand in Denmark. In this paper we look at optimal expansion of the transmission network in order to integrate 50% wind power in the system, while minimizing total fixed investment cost and expected cost...... of power generation. We allow for active switching of transmission elements to reduce congestion effects caused by Kirchhoff's voltage law. Results show that actively switching transmission lines may yield a better utilization of transmission networks with large-scale wind power and increase wind power...... penetration. Furthermore, it is shown that transmission switching is likely to affect the optimal line capacity expansion plan....

  9. A Hybrid Optimization Method for Reactive Power and Voltage Control Considering Power Loss Minimization

    DEFF Research Database (Denmark)

    Liu, Chengxi; Qin, Nan; Bak, Claus Leth

    2015-01-01

    This paper proposes a hybrid optimization method to optimally control the voltage and reactive power with minimum power loss in transmission grid. This approach is used for the Danish automatic voltage control (AVC) system which is typically a non-linear non-convex problem mixed with both...

  10. Control of a Two-Stage Direct Power Converter with a Single Voltage Sensor Mounted in the Intermediary Circuit

    DEFF Research Database (Denmark)

    Klumpner, Christian; Wheeler, P.; Blaabjerg, Frede

    2004-01-01

    Controlling a converter requires not only a powerful processors but also accurate voltage and current sensors and fast and precise analogue-digital converters, which increase the cost per kW of the assembly, especially in the low power range. A matrix converter requires less transducers than a back......-wave out operation while using a single voltage sensor mounted in the intermediary link between the rectification and the inversion stages and the information of the sign of the input line-to-line voltages, which is needed anyway for the safe-commutation of the rectification stage....

  11. Voltage control in the future power transmission systems

    DEFF Research Database (Denmark)

    Qin, Nan

    to ensure a highly reliable transmission, e.g. balancing the generation and the consumption in large geographic regions, the exchange capacities will be enlarged by upgrading the interconnections. The Danish power system, the electricity transportation hub between the Nordic and continental European systems......, driving by the market, is highly flexible. As more and more renewable energy integrating to the system, the voltage control in the future power system is becoming a challenging objective. This project considering the future challenges is to design a robust Automatic Voltage Control (AVC) system...... is strongly tractable for improving the robustness. In case the centralized AVC system is malfunctioning, e.g. telecommunications fails, the distributed fallback controllers will take the control responsibility to maintain the voltage in the acceptable band. The fallback scheme installed at substations...

  12. Novel design for a high power superconducting delay line

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.J.; Caporaso, G.J.

    1997-05-08

    Potential designs for a high power superconducting delay line of approximately 10ms duration are described. The transmitted signal should have low dispersion and little attenuation to recapture the original signal. Such demands cannot be met using conventional metal conductors. This paper outlines a proposal for a new transmission line design using low temperature superconducting material which meets system specifications. The 25W line is designed to carry pulsed signals with an approximate rise time of 8 nsec and a maximum voltage of 25kV. Predicted electrical design and performance of the line is presented.

  13. Designs for a high power superconducting delay line

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y.J.; Caporaso, G.

    1997-06-26

    Potential designs for a high power superconducting delay line of approximately 10 microsecs duration are described. The transmitted signal should have low dispersion and little attenuation to recapture the original signal. Such demands cannot be met using conventional metal conductors. This paper outlines a proposal for a new transmission line design using low temperature superconducting material which meets system specifications. The 25 omega line is designed to carry pulsed signals with an approximate rise time of 8 nsec and a maximum voltage magnitude of 25 kV. Predicted electrical design and performance of the line will be presented.

  14. Power Restoration in Medium Voltage Network Using Multiagent System

    Directory of Open Access Journals (Sweden)

    Miroslav Kovac

    2013-01-01

    Full Text Available The article describes a novel approach to a power restoration in medium voltage power distribution network. It focuses primary at searching of a new network configuration enabling to minimalize the size of faulted area and to restore the power for the highest possible number of loads. It describes characteristic features of medium voltage power distribution network and discusses the implementation of the presented approach in existing networks. A software tool, developed by the authors, including physical simulation of model network and its autonomous control system is described. An example of fault situation in a virtual distribution network is presented. Afterwards, the solution of restoration problem by proposed multiagent system is simulated using the software tool described in the paper.

  15. Distance protection of multiple-circuit shared tower transmission lines with different voltages. Part II: Fault loop impedance

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. In this paper, the fault loop impedance of combined faults is compared with the fault loop impedance...... of single-phase-to-ground faults at the higher voltage level of the multiple-circuit line and it is demonstrated that they are similar for high short-circuit powers; however, the fault loop impedance of a combined fault may increase substantially as the short-circuit power of the system decreases......, a behaviour that is less noticeable in single-phase-to-ground faults. It is also demonstrated that the fault loop impedance of combined faults is more resistive when compared with equivalent single-phase-to-ground faults. It is concluded that the settings used to protect a line against single...

  16. Decentralized Adaptive Overcurrent Protection for Medium Voltage Maritime Power Systems

    DEFF Research Database (Denmark)

    Ciontea, Catalin-Iosif; Bak, Claus Leth; Blaabjerg, Frede

    2016-01-01

    control unit. The new adaptive protection method is based on communication between the overcurrent relays and the equipment that could affect the protection system, such as circuit breakers and generators. Using PSCAD, the proposed method is implemented in a test medium voltage maritime power system...

  17. The commercial development of water repellent coatings for high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, S. R. [ORNL; Daniel, A. [Southwire Company

    2013-10-31

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

  18. The commercial development of water repellent coatings for high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, Scott Robert [ORNL

    2013-10-01

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

  19. Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages

    Directory of Open Access Journals (Sweden)

    ISTRATE, M.

    2009-10-01

    Full Text Available The increased accuracy into the fault's detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids' lines are presented. The double-end synchronized data algorithms are very precise, but the current transformers can limit the accuracy of these estimations. The paper presents an algorithm to estimate the location of the single-phased faults which uses only voltage measurements at both terminals of the transmission lines by eliminating the error due to current transformers and without introducing the restriction of perfect data synchronization. In such conditions, the algorithm can be used with the actual equipment of the most power grids, the installation of phasor measurement units with GPS system synchronized timer not being compulsory. Only the positive sequence of line parameters and sources are used, thus, eliminating the incertitude in zero sequence parameter estimation. The algorithm is tested using the results of EMTP-ATP simulations, after the validation of the ATP models on the basis of registered results in a real power grid.

  20. Reactive Power and Voltage Control of Offshore Wind Farms

    OpenAIRE

    Jerkø, Anders

    2014-01-01

    There are several challenges related to reactive power and voltage control of HVAC transmission from offshore wind farms to the main grid, which need to be addressed when designing wind farms. One challenge is the variation of wind speeds and thereby also power production, which can make it difficult to operate the system within the grid code requirements. This Master s thesis focuses on finding beneficial operating strategies to solve these challenges. Various locations of a static var compe...

  1. Voltage sensitivity based reactive power control on VSC-HVDC in a wind farm connected hybrid multi-infeed HVDC system

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2013-01-01

    With increasing application of both Line Commutated Converter based High Voltage Direct Current (LCC-HVDC) systems and Voltage Source Converter based HVDC (VSC-HVDC) links, a new type of system structure named Hybrid Multi-Infeed HVDC (HMIDC) system is formed in the modern power systems. This paper...... presents the operation and control method of the wind farm connected HMIDC system. The wind power fluctuation takes large influence to the system voltages. In order to reduce the voltage fluctuation of LCC-HVDC infeed bus caused by the wind power variation, a voltage sensitivity-based reactive power...

  2. 76 FR 26183 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Science.gov (United States)

    2011-05-06

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Repair of High Voltage Transmission Lines... transmission lines to Logan Airport. This safety zone is required to provide for the safety of life on navigable waters during the repair of high voltage transmission lines. Entering into, transiting through...

  3. Preparation of Power Distribution System for High Penetration of Renewable Energy Part I. Dynamic Voltage Restorer for Voltage Regulation Pat II. Distribution Circuit Modeling and Validation

    Science.gov (United States)

    Khoshkbar Sadigh, Arash

    by simulation and experimental tests under various conditions considering all possible cases such as different amounts of voltage sag depth (VSD), different amounts of point-on-wave (POW) at which voltage sag occurs, harmonic distortion, line frequency variation, and phase jump (PJ). Furthermore, the ripple amount of fundamental voltage amplitude calculated by the proposed method and its error is analyzed considering the line frequency variation together with harmonic distortion. The best and worst detection time of proposed method were measured 1ms and 8.8ms, respectively. Finally, the proposed method has been compared with other voltage sag detection methods available in literature. Part 2: Power System Modeling for Renewable Energy Integration: As power distribution systems are evolving into more complex networks, electrical engineers have to rely on software tools to perform circuit analysis. There are dozens of powerful software tools available in the market to perform the power system studies. Although their main functions are similar, there are differences in features and formatting structures to suit specific applications. This creates challenges for transferring power system circuit models data (PSCMD) between different software and rebuilding the same circuit in the second software environment. The objective of this part of thesis is to develop a Unified Platform (UP) to facilitate transferring PSCMD among different software packages and relieve the challenges of the circuit model conversion process. UP uses a commonly available spreadsheet file with a defined format, for any home software to write data to and for any destination software to read data from, via a script-based application called PSCMD transfer application. The main considerations in developing the UP are to minimize manual intervention and import a one-line diagram into the destination software or export it from the source software, with all details to allow load flow, short circuit and

  4. Factor affecting characteristic of voltage sag due to fault in the power system

    Directory of Open Access Journals (Sweden)

    Patne Nita R.

    2008-01-01

    Full Text Available Faults in the power system are the most common reason for the occurrence of important power quality problem, voltage sag in the system. Due to increasing use of sensitive and sophisticated control in almost all modern devices at the industrial and residential consumer level, the Voltage sag which causes severe problems to these devices needs to be analyzed. Factors which affect the characteristics of voltage sag as a type of fault in the system, location of fault in the system, X/R ratio of transmission lines, type of transmission as single or double circuit transmission, Point on wave of sag initiation are studied in this paper. PSCAD/EMTDC is used as a simulation tool.

  5. High power, medium voltage, series resonant converter for DC wind turbines

    DEFF Research Database (Denmark)

    Dincan, Catalin Gabriel; Kjær, Philip Carne; Chen, Yu-Hsing

    2017-01-01

    A new modulation scheme is introduced for a single-phase series-resonant converter, which permits continuous regulation of power from nominal level to zero, in presence of variable input and output dc voltage levels. Rearranging the circuit to locate the resonant LC tank on the rectifier side...... of the high turns-ratio transformer combined with frequency control and phase-shifted inverter modulation keep transformer flux constant from nominal frequency down to DC, always in sub-resonant continuous or discontinuous conduction mode. This overcomes the principal deficit of series-resonant converters......, and the resulting compact and efficient transformer, and soft-commutated inverter, present particular advantages in high-power, high-voltage applications, like DC offshore wind turbines. With transformer excitation frequency in hundreds of Hz range, line-frequency diodes can be employed in the high-voltage...

  6. Global Transient Stability and Voltage Regulation for Multimachine Power Systems

    DEFF Research Database (Denmark)

    Gordon, Mark; Hill, David J.

    2008-01-01

    This paper addresses simultaneously the major fundamental and difficult issues of nonlinearity, uncertainty, dimensionality and globality to derive performance enhancing power system stability control. The main focus is on simultaneous enhancement of transient stability and voltage regulation...... Linearization (DFL) technique together with the robust control theory has been further developed and applied to design nonlinear excitation compensators which selectively eliminate system nonlinearities and deal with plant uncertainties and interconnections between generators. Then the so called global control...... law is implemented to coordinate transient stabilizer and voltage regulator for each machine. Digital simulation studies show that global control scheme achieves unified transient stability and voltage regulation in the presence of parametric uncertainties and significant sudden changes in the network...

  7. Automatic Power Line Inspection Using UAV Images

    Directory of Open Access Journals (Sweden)

    Yong Zhang

    2017-08-01

    Full Text Available Power line inspection ensures the safe operation of a power transmission grid. Using unmanned aerial vehicle (UAV images of power line corridors is an effective way to carry out these vital inspections. In this paper, we propose an automatic inspection method for power lines using UAV images. This method, known as the power line automatic measurement method based on epipolar constraints (PLAMEC, acquires the spatial position of the power lines. Then, the semi patch matching based on epipolar constraints (SPMEC dense matching method is applied to automatically extract dense point clouds within the power line corridor. Obstacles can then be automatically detected by calculating the spatial distance between a power line and the point cloud representing the ground. Experimental results show that the PLAMEC automatically measures power lines effectively with a measurement accuracy consistent with that of manual stereo measurements. The height root mean square (RMS error of the point cloud was 0.233 m, and the RMS error of the power line was 0.205 m. In addition, we verified the detected obstacles in the field and measured the distance between the canopy and power line using a laser range finder. The results show that the difference of these two distances was within ±0.5 m.

  8. The study process for the environmental evaluation of new high voltage power transmission lines in Togo and Benin; La demarche d'etude et d'evaluation environnementale des nouvelles lignes electroniques a haute tension au Togo et au Benin

    Energy Technology Data Exchange (ETDEWEB)

    Houessou, S. [Communaute Electrique du Benin, Lome (Togo)

    2009-04-15

    New guidelines have been established for evaluating the environmental implications of constructing 2,000 km of new high voltage power transmission lines in Benin and Togo, Africa. Prior to approval, the technical feasibility of the project must be proven in terms of topography, economics, ease of access, execution of works, and avoiding urban and environmentally sensitive areas. In order to address management problems the World Bank required that the technical and environmental studies be done by two different consultants. This approach has been used since 2006, and has helped save time, costs, and helped to strengthen the use of local expertise. Each project involved 3 phases. The measures taken for the approval of the new power lines relied on the originality of impact studies and the recruitment of an experienced master developer. 1 tab., 1 fig.

  9. Distributed voltage control and load sharing for inverter-interfaced microdrid with resistive lines

    DEFF Research Database (Denmark)

    Golsorkhi, Mohammad S.; Lu, D. D C; Shafiee, Q.

    2016-01-01

    method is based upon the practical assumption of resistive network impedance. In this context, a V-I droop mechanism is adopted in the primary control level, where GPS timing is used to synchronize the control agents. A new distributed secondary control method based on consensus protocol is introduced......This paper proposes a new distributed control method for coordination of distributed energy resources (DERs) in low-voltage resistive microgrids. The proposed framework consists of two level structure; primary and secondary control. Unlike the existing distributed control methods, the proposed......-axis component of voltage is adjusted to perform proper current and, accordingly reactive power sharing. The proposed control methodology accounts for the distribution line impedances. It features a plug-and-play environment; prior system knowledge is not required, and an arbitrary DER can enter the microgrid...

  10. Evaluation of high-voltage, high-power, solid-state remote power controllers for amps

    Science.gov (United States)

    Callis, Charles P.

    1987-01-01

    The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.

  11. Wind Power Impact to Transient and Voltage Stability of the Power System in Eastern Denmark

    DEFF Research Database (Denmark)

    Rasmussen, Joana; Jørgensen, Preben; Palsson, Magni Thor

    2005-01-01

    Voltage stability, transient stability and reactive power compensation are extremely important issues for largescale integration of wind power in areas distant from the main transmission system in Eastern Denmark. This paper describes the application of a dynamic wind farm model in simulation...... studies for assessments of a large wind power penetration. The simulation results reveal problems with voltage stability due to the characteristic of wind turbine generation as well as the inability of the power system to meet the reactive power demand. Furthermore, the established model is applied...

  12. Hybrid zero-voltage switching (ZVS) control for power inverters

    Science.gov (United States)

    Amirahmadi, Ahmadreza; Hu, Haibing; Batarseh, Issa

    2016-11-01

    A power inverter combination includes a half-bridge power inverter including first and second semiconductor power switches receiving input power having an intermediate node therebetween providing an inductor current through an inductor. A controller includes input comparison circuitry receiving the inductor current having outputs coupled to first inputs of pulse width modulation (PWM) generation circuitry, and a predictive control block having an output coupled to second inputs of the PWM generation circuitry. The predictive control block is coupled to receive a measure of Vin and an output voltage at a grid connection point. A memory stores a current control algorithm configured for resetting a PWM period for a switching signal applied to control nodes of the first and second power switch whenever the inductor current reaches a predetermined upper limit or a predetermined lower limit.

  13. An ultra low-power off-line APDM-based switchmode power supply with very high conversion efficiency

    DEFF Research Database (Denmark)

    Nielsen, Nils

    2001-01-01

    This article describes the results from the research work on design of a ultra low power off-line power supply with very high conversion efficiency. The input voltage is 230 VAC nominal and output voltage is 5 VDC. By ultra low power levels, an output power level in the area ranging from 50 mW an......W and up to 1000 mW is meant. The small power supply is intended for use as a standby power supply in mains operated equipment, which requires a small amount of power in standby mode....

  14. 30 CFR 75.812-2 - High-voltage power centers and transformers; record of examination.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage power centers and transformers... High-Voltage Distribution § 75.812-2 High-voltage power centers and transformers; record of examination... record shall be kept in a book approved by the Secretary. High-Voltage Longwalls Source: 67 FR 11001, Mar...

  15. 30 CFR 77.704 - Work on high-voltage lines; deenergizing and grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Work on high-voltage lines; deenergizing and grounding. 77.704 Section 77.704 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Grounding § 77.704 Work on high-voltage lines; deenergizing and grounding...

  16. 30 CFR 75.705 - Work on high-voltage lines; deenergizing and grounding.

    Science.gov (United States)

    2010-07-01

    ... grounding. 75.705 Section 75.705 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.705 Work on high-voltage lines; deenergizing and grounding. High-voltage lines, both on the surface and...

  17. Development of Live-working Robot for Power Transmission Lines

    Science.gov (United States)

    Yan, Yu; Liu, Xiaqing; Ren, Chengxian; Li, Jinliang; Li, Hui

    2017-07-01

    Dream-I, the first reconfigurable live-working robot for power transmission lines successfully developed in China, has the functions of autonomous walking on lines and accurately positioning. This paper firstly described operation task and object of the robot; then designed a general platform, an insulator replacement end and a drainage plate bolt fastening end of the robot, presented a control system of the robot, and performed simulation analysis on operation plan of the robot; and finally completed electrical field withstand voltage tests in a high voltage hall as well as online test and trial on actual lines. Experimental results show that by replacing ends of manipulators, the robot can fulfill operation tasks of live replacement of suspension insulators and live drainage plate bolt fastening.

  18. Direct harmonic voltage control strategy for shunt active power filter

    DEFF Research Database (Denmark)

    Munir, Hafiz Mudassir; Zou, JianXiao; Xie, Chuan

    2017-01-01

    Shunt active power filters (S-APF) are highly popular ways for harmonic compensation due to the high performance and simplicity of installation. S-APF is commonly controlled in current control mode with load harmonic current detection, which is not quite suitable for the distributed power...... generation system (DPGS) where the nonlinear loads are highly dispersed. Local harmonic voltage detection based Resistive-APF (R-APF) seems more suitable to be applied in the DPGS, however, R-APF suffers from poor compensation performance and difficulty of parameter tuning. In this paper, a direct harmonic...

  19. Theoretical Analysis of Tuned HVAC Line for Low Loss Long Distance Bulk Power Transmission

    OpenAIRE

    Ukil, Abhisek

    2015-01-01

    One of the main objectives of the smart grid initiative is to enable bulk power transmission over long distance, with reduced transmission losses. Besides the traditional high-voltage alternating current (HVAC) transmission, with the advancement in power electronics, high-voltage direct current (HVDC) transmission is increasingly becoming important. One of the main factors impacting the transmission line parameters and the losses is the length of the transmission line (overhead). In this pape...

  20. Underground power line fault locating system

    Energy Technology Data Exchange (ETDEWEB)

    Fox, L.D.; Flath, R.K.

    1993-08-24

    A method is described of locating a fault in a polyphase power distribution system power distributing power from a bulk power source to power consumers, the power distribution system having a substation feeding a fused switch gear unit, a first vault, and at least one subsequent vault receiving power from the first vault, the first vault distributing power from the fused switch gear unit among plural outgoing underground power lines, each underground outgoing power line supplying power to at least one power consumer, the method comprising the steps of: checking fusing within the fused switch gear unit to determine in which phase the fault has occurred; checking the continuity of a power line interconnecting the fused switch gear unit and the first vault; identifying the fused switch gear unit and the first vault which normally supply power to a line having the fault; installing a fault indicator on each underground outgoing power line of the faulted phase in the first vault and in each subsequent vault; inserting a current limiting fuse in series with and between the fused switch gear unit and the first vault; reenergizing the first vault plural outgoing underground power lines through the current limiting fuse and causing the current limiting fuse to blow; and reading each fault indicator after the reenergizing step to determine the location of the fault. A method according to claim 7 for an underground power distribution system wherein at least one underground outgoing power line delivers power to at least one distribution transformer, wherein the step of installing the fault indicators further comprises installing a fault indicator on each distribution transformer.

  1. Strategies for Power Line Communications Smart Metering Network Deployment

    OpenAIRE

    Alberto Sendin; Ivan Peña; Pablo Angueira

    2014-01-01

    Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS) existing in the grid, covering the Low Voltage (LV) segment with the lowest possible costs. Power Line Communications (PLC) have been extensively used in electricity grids ...

  2. Static reactive power compensators for high-voltage power systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-04-01

    A study conducted to summarize the role of static reactive power compensators for high voltage power system applications is described. This information should be useful to the utility system planning engineer in applying static var systems (SVS) to high voltage as (HVAC) systems. The static var system is defined as a form of reactive power compensator. The general need for reactive power compensation in HVAC systems is discussed, and the static var system is compared to other devices utilized to provide reactive power compensation. Examples are presented of applying SVS for specific functions, such as the prevention of voltage collapse. The operating principles of commercially available SVS's are discussed in detail. The perormance and active power loss characteristics of SVS types are compared.

  3. Comparative Analysis of Voltage Control in Battery Power Converters for Inverter-Based AC Microgrids

    National Research Council Canada - National Science Library

    Chae, Woo-Kyu; Won, Jong-Nam; Lee, Hak-Ju; Kim, Jae-Eon; Kim, Jaehong

    2016-01-01

    .... The energy storage system power converters generally form the local AC bus voltage. This grid-forming operation requires fast and robust voltage control to properly maintain a stable energy flow and high power quality in the local AC bus...

  4. Development of Voltage Regulation Plan by Composing Subsystem with the SFES for DC On-line Electric Vehicle

    Science.gov (United States)

    Jung, S.; Lee, J. H.; Yoon, M.; Lee, H.; Jang, G.

    The study of the application process of the relatively small size 'Superconducting Flywheel Energy Storage (SFES)' system is conducted to regulate voltage fluctuation of the DC On-Line Electric Vehicle (OLEV) system, which is designed by using DC power system network. It is recommended to construct the power conversion system nearby the substation because the charging system is under the low voltage. But as the system is usually built around urban area and it makes hard to construct the subsystems at every station, voltage drop can occur in power supply inverter that is some distance from the substation. As the alternative of this issue, DC distribution system is recently introduced and has possibility to solve the above issue. In this paper, SFES is introduced to solve the voltage drop under the low voltage distribution system by using the concept of the proposed DC OLEV which results in building the longer distance power supply system. The simulation to design the SFES by using DC power flow analysis is carried out and it is verified in this paper.

  5. Coordination of voltage and reactive power control in the extra high voltage substations based on the example of solutions applied in the national power system

    Directory of Open Access Journals (Sweden)

    Dariusz Kołodziej

    2012-06-01

    Full Text Available This paper presents examples of coordination between automatic voltage and reactive power control systems (ARST covering adjacent and strongly related extra high voltage substations. Included are conclusions resulting from the use of these solutions. The Institute of Power Engineering, Gdańsk Division has developed and deployed ARST systems in the national power system for a dozen or so years.

  6. Solid-state fast voltage compensator for pulsed power applications requiring constant AC power consumption

    CERN Document Server

    Magallanes, Francisco Cabaleiro; Viarouge, Philippe; Cros, Jérôme

    2015-01-01

    This paper proposes a novel topological solution for pulsed power converters based on capacitor-discharge topologies, integrating a Fast Voltage Compensator which allows an operation at constant power consumption from the utility grid. This solution has been retained as a possible candidate for the CLIC project under study at CERN, which requires more than a thousand synchronously-operated klystron modulators producing a total pulsed power of almost 40 GW. The proposed Fast Voltage Compensator is integrated in the modulator such that it only has to treat the capacitor charger current and a fraction of the charging voltage, meaning that its dimensioning power and cost are minimized. This topology can be used to improve the AC power quality of any pulsed converters based on capacitor-discharge concept. A prototype has been built and exploited to validate the operating principle and demonstrate the benefits of the proposed solution.

  7. Review of mixer design for low voltage - low power applications

    Science.gov (United States)

    Nurulain, D.; Musa, F. A. S.; Isa, M. Mohamad; Ahmad, N.; Kasjoo, S. R.

    2017-09-01

    A mixer is used in almost all radio frequency (RF) or microwave systems for frequency translation. Nowadays, the increase market demand encouraged the industry to deliver circuit designs to create proficient and convenient equipment with very low power (LP) consumption and low voltage (LV) supply in both digital and analogue circuits. This paper focused on different Complementary Metal Oxide Semiconductor (CMOS) design topologies for LV and LP mixer design. Floating Gate Metal Oxide Semiconductor (FGMOS) is an alternative technology to replace CMOS due to their high ability for LV and LP applications. FGMOS only required a few transistors per gate and can have a shift in threshold voltage (VTH) to increase the LP and LV performances as compared to CMOS, which makes an attractive option to replace CMOS.

  8. Distance protection of multiple-circuit shared tower transmission lines with different voltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. This study presents a detailed theoretical analysis of such combined faults, including the development...... of a formula for estimating the magnitude of the short-circuit current. It is demonstrated that if the faulted phase from the higher voltage level leads the faulted phase from the lower voltage level, a distance relay at the higher voltage level sees the fault in the forward direction, whereas a distance relay...... at the lower voltage level sees the fault in the reverse direction. The opposite happens if the lower voltage level leads the higher voltage level. It is also demonstrated that the magnitude of fault currents of combined faults is normally slightly larger than of equivalent single-phase-to-ground fault...

  9. Power line communications theory and applications for narrowband and broadband communications over power lines

    CERN Document Server

    Ferreira, Hendrik C; Newbury, John; Swart, Theo G

    2010-01-01

    Power Line Communications (PLC) is a promising emerging technology, which has attracted much attention due to the wide availability of power distribution lines. This book provides a thorough introduction to the use of power lines for communication purposes, ranging from channel characterization, communications on the physical layer and electromagnetic interference, through to protocols, networks, standards and up to systems and implementations. With contributions from many of the most prominent international PLC experts from academia and industry, Power Line Communications brings togeth

  10. ENVIRONMENTAL POLLUTION BY MAGNETIC FIELD AROUND POWER LINES

    Directory of Open Access Journals (Sweden)

    Vesna Ranković

    2009-09-01

    Full Text Available According to the contemporary epidemiological researches, there are some indications that extremely low frequency electromagnetic fields harm human health which has been proved through numerous scientific studies published in recent years. Today, most countries use the ICNIRP guidelines and Council Recommendation as the scientific basis for their recommended levels of exposure. Magnetic fields from high voltage transmission power lines have been discussed in this paper. The field profiles and their contribution to environmental pollution are studied. The obtained results are found to be useful for discussing the comparison of the field densities on the human body at the ground level under or near the lines.

  11. Surge currents and voltages at the low voltage power mains during lightning strike to a GSM tower

    Energy Technology Data Exchange (ETDEWEB)

    Markowska, Renata [Bialystok Technical University (Poland)], E-mail: remark@pb.edu.pl

    2007-07-01

    The paper presents the results of numerical calculations of lightning surge currents and voltages in the low voltage power mains system connected to a free standing GSM base station. Direct lightning strike to GSM tower was studied. The analysis concerned the current that flows to the transformer station through AC power mains, the potential difference between the grounding systems of the GSM and the transformer stations and the voltage differences between phase and PE conductors of the power mains underground cable at both the GSM and the transformer sides. The calculations were performed using a numerical program based on the electromagnetic field theory and the method of moments. (author)

  12. Development of real-time voltage stability monitoring tool for power system transmission network using Synchrophasor data

    Science.gov (United States)

    Pulok, Md Kamrul Hasan

    Intelligent and effective monitoring of power system stability in control centers is one of the key issues in smart grid technology to prevent unwanted power system blackouts. Voltage stability analysis is one of the most important requirements for control center operation in smart grid era. With the advent of Phasor Measurement Unit (PMU) or Synchrophasor technology, real time monitoring of voltage stability of power system is now a reality. This work utilizes real-time PMU data to derive a voltage stability index to monitor the voltage stability related contingency situation in power systems. The developed tool uses PMU data to calculate voltage stability index that indicates relative closeness of the instability by producing numerical indices. The IEEE 39 bus, New England power system was modeled and run on a Real-time Digital Simulator that stream PMU data over the Internet using IEEE C37.118 protocol. A Phasor data concentrator (PDC) is setup that receives streaming PMU data and stores them in Microsoft SQL database server. Then the developed voltage stability monitoring (VSM) tool retrieves phasor measurement data from SQL server, performs real-time state estimation of the whole network, calculate voltage stability index, perform real-time ranking of most vulnerable transmission lines, and finally shows all the results in a graphical user interface. All these actions are done in near real-time. Control centers can easily monitor the systems condition by using this tool and can take precautionary actions if needed.

  13. ANÁLISIS Y ESTUDIO DEL DESEMPEÑO DE LOS ENTRELAZADORES DE BITS DE BLOQUE, DORADO Y DORADO RELATIVO EN UN CANAL DE LÍNEA ELÉCTRICA DE BAJA TENSIÓN ANALYSIS OF THE PERFORMANCE OF THE INTERLEAVERS OF BLOCK, GOLDEN AND RELATIVE GOLDEN IN A OF LOW VOLTAGE POWER LINE CHANNEL

    Directory of Open Access Journals (Sweden)

    Washington Fernández R

    2008-09-01

    Full Text Available En este trabajo se analizan y se estudian tres tipos de entrelazadores de bit: bloque, dorado y dorado relativo, y se determina su desempeño en un canal de línea eléctrica de baja tensión. Se utiliza el modelo de ruido dado por Middleton, para la simulación del canal de línea eléctrica de baja tensión y el algoritmo que se utiliza para generar ruido gaussiano es el método de Box-Muller. Se compara el desempeño de los entrelazadores de bits de bloque, dorado y dorado relativo, en relación al largo de la palabra versus la razón de señal a ruido y bits erróneos por palabras versus la razón de señal a ruido. La codificación de línea que se utiliza es no retorno a cero. El entrelazador de bit dorado es el que tiene el mejor desempeño, por lo tanto, se puede emplear en la transmisión por línea eléctrica de baja tensión para disminuir los errores de bits consecutivos producido por el ruido impulsivo.This paper analyzes three types of interleavers: block, golden and golden relative to determine their performance in of low voltage power line channel. The model of noise given by Middleton is used for the simulation of the low voltage power line channel and the algorithm used to generate Gaussian noise is based on the Box-Muller method. The performance of interleavers block, golden and golden relative is compared in relationship to the length of the words versus the signal to noise ratio. The error bit by word versus signal to noise ratio is compared also. The codification of line used is no return to zero. It is concluded that the interleavers of golden has the best performance, thus it can be used in data transmission in low-voltage power line, reducing errors consecutive bits produced by impulse noise.

  14. A Novel Design of Radio Frequency Energy Relays on Power Transmission Lines

    OpenAIRE

    Jin Tong; Yigang He; Bing Li; Fangming Deng; Tao Wang

    2016-01-01

    In this paper, we investigate the energy problem of monitoring sensors on high-voltage power transmission lines and propose a wireless charging scheme for a Radio Frequency IDentification (RFID) sensor tag to solve a commercial efficiency problem: the maintenance-caused power outage. Considering the environmental influences on power transmission lines, a self-powered wireless energy relay is designed to meet the energy requirement of the passive RFID sensor tag. The relay can obtain the elect...

  15. Prerequisites of the automated system of monitoring and early diagnosis of the state of high-voltage lines

    Directory of Open Access Journals (Sweden)

    Михайло Дмитрович Дяченко

    2015-03-01

    Full Text Available Violation of the contact connection leads either to breakage of the conductor, or fire equipment. Currently, for technical inspection of high voltage contact connections used method of thermal control or periodic visual inspection. Such control of long power lines becomes expensive. Therefore, to improve the reliability of connections required automatic condition monitoring of high-voltage contact connections. The system consists of a set of intelligent modules, located directly to contact connection and continuously measure its temperature and contact resistance. Microprocessor control module has a continuous connection with the same modules on other low-power contact connections via packet radio transceiver. The basis of the organization of an information network on the concept of self-organizing sensor networks. In it, each intelligent module performs the function of a router. It solves the problem of finding an optimal route data to central control. He can change the decision if conditions change operation transceiver equipment. This solution allows using a low-power transmitter to provide coverage in the long power lines more than hundreds km. And provide excellent data transmission quality. The proposed system allows continuous monitoring of each high-voltage power system contact connection, predict rejection of degradation of each of them and thus improve the reliability of power supply in general

  16. Analysis of crowbar action of high voltage DC power supply in the LHD ICRF system

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiaodong [Southwestern Institute of Physics, Chengdu, Sichuan (China); Mutoh, T.; Kumazawa, R.; Watari, T.; Seki, T.; Shimpo, F.; Nomura, G.; Saito, K.

    1999-04-01

    Ion Cyclotron Range of Frequency (ICRF) heating will be applied to the Large Helical Device (LHD) at the 2nd experimental campaign in 1998. The LHD ICRF system is characterised by its high power (up to 12 MW at final stage) and steady state operation for more than 30 minutes. One of the main R and D items was a high power and steady state transmitter. The RF transmitter system having a wide frequency range from 25 to 95 MHz was designed and fabricated. This report describes the analysis of the DC power supply that contains the crowbar circuit protecting the tetrode from the arcing inside the tube. The DC power supply of the transmitter is fed from the commercial AC electric line which also supply the power to the LHD helical and poloidal coil power supplies. The voltage drop of the commercial line when the ICRF crowbar action happened is the serious problem for all experimental system. This paper analyses the crowbar effect on the commercial line with and without leakage transformer between the step-up transformer of transmitter and the commercial line. (author)

  17. Design and power management of an offshore medium voltage DC microgrid realized through high voltage power electronics technologies and control

    Science.gov (United States)

    Grainger, Brandon Michael

    The growth in the electric power industry's portfolio of Direct Current (DC) based generation and loads have captured the attention of many leading research institutions. Opportunities for using DC based systems have been explored in electric ship design and have been a proven, reliable solution for transmitting bulk power onshore and offshore. To integrate many of the renewable resources into our existing AC grid, a number of power conversions through power electronics are required to condition the equipment for direct connection. Within the power conversion stages, there is always a requirement to convert to or from DC. The AC microgrid is a conceptual solution proposed for integrating various types of renewable generation resources. The fundamental microgrid requirements include the capability of operating in islanding mode and/or grid connected modes. The technical challenges associated with microgrids include (1) operation modes and transitions that comply with IEEE1547 without extensive custom engineering and (2) control architecture and communication. The Medium Voltage DC (MVDC) architecture, explored by the University of Pittsburgh, can be visualized as a special type of DC microgrid. This dissertation is multi-faceted, focused on many design aspects of an offshore DC microgrid. The focal points of the discussion are focused on optimized high power, high frequency magnetic material performance in electric machines, transformers, and DC/DC power converters---all components found within offshore, power system architectures. A new controller design based upon model reference control is proposed and shown to stabilize the electric motor drives (modeled as constant power loads), which serve as the largest power consuming entities in the microgrid. The design and simulation of a state-of-the-art multilevel converter for High Voltage DC (HVDC) is discussed and a component sensitivity analysis on fault current peaks is explored. A power management routine is

  18. Fiber optic voltage sensor for 420 kV electric power systems

    Science.gov (United States)

    Bohnert, Klaus M.; Kostovic, Jadran; Pequignot, P.

    2000-11-01

    We present an optical fiber voltage sensor for 420 kV electric power lines. The sensor exploits the converse piezoelectric effect of quartz and measures the voltage by a line integration of the electric field. The alternating voltage is partitioned to a series of four cylinder-shaped quartz crystals, which are embedded in polyurethane resin within a 3.2-m long insulator tube of fiber reinforced epoxy. The alternating piezoelectric deformations of the crystals are sensed by a common elliptical-core dual-mode fiber, which is wound onto the circumferential crystal surfaces. The fiber is interrogated using low coherence interferometry. We determine the dielectric design of the sensor from a numerical analysis of the electric field distribution within and in the vicinity of the sensor. We experimentally verify the dielectric reliability under ac overvoltages up to 520 kV root mean square and lightning and switching impulse voltages up to 1425 and 1050 kV, respectively. Further, we investigate the sensor performance including accuracy, dynamic range, bandwidth, and temperature dependence.

  19. Using a Voltage Domain Programmable Technique for Low-Power Management Cell-Based Design

    Directory of Open Access Journals (Sweden)

    Ching-Hwa Cheng

    2011-09-01

    Full Text Available The Multi-voltage technique is an effective way to reduce power consumption. In the proposed cell-based voltage domain programmable (VDP technique, the high and low voltages applied to logic gates are programmable. The flexible voltage domain reassignment allows the chip performance and power consumption to be dynamically adjusted. In the proposed technique, the power switches possess the feature of flexible programming after chip manufacturing. This VDP method does not use an external voltage regulator to regulate the supply voltage level from outside of the chip but can be easily integrated within the design. This novel technique is proven by use of a video decoder test chip, which shows 55% and 61% power reductions compared to conventional single-Vdd and low-voltage designs, respectively. This power-aware performance adjusting mechanism shows great power reduction with a good power-performance management mechanism.

  20. FUZZY LOGIC CONTROLLER BASED ACTIVE POWER LINE CONDITIONERS FOR COMPENSATING REACTIVE POWER AND HARMONICS

    Directory of Open Access Journals (Sweden)

    Karuppanan.P

    2010-07-01

    Full Text Available This article explores a novel fuzzy logic controller (FLC based threephase shunt active power line conditioners (APLC for power quality improvements due to the non-linear loads. The fuzzy logic controller is Mamdani-type and linguistic description, so it does not necessitate a mathematical model of the system. The FLC controller is capable of controlling harmonic current and dc-side capacitor voltage of the inverter to improve the performance of the active power filter. Hysteresis current controller (HCC is used to generate the switching signals from the comparison of reference current and actual current for driving the current controlled voltage source inverter (VSI. Extensive simulation executed and tested under different non-linear load conditions. The simulation results reveal that the APLC with fuzzy logic controller is a perfect candidate for current harmonics and reactive power compensation.

  1. Elk and plants thrive near power lines

    Energy Technology Data Exchange (ETDEWEB)

    Lustre, L.

    1997-11-01

    Butterflies and elk gather in clearings near power line right-of-ways and on the edges of such clearings, where the wild flowers and plants that have widely disappeared as a result of intensive farming and subsurface drainage of fields have found a good habitat. Ornamental coniferous trees, various herbs and assorted berries do well and can be harvested near power lines from woodland clearings once thought unfit for cultivation. IVS, the nationwide network company, takes part in many projects aiming both to increase productive utilization of land areas under power lines and to promote biodiversity

  2. Limiting electric fields of HVDC overhead power lines.

    Science.gov (United States)

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  3. Architecture for a High-to-Medium-Voltage Power Converter

    Science.gov (United States)

    Vorpenian, Vatche

    2008-01-01

    A power converter now undergoing development is required to operate at a DC input potential ranging between 5.5 and 10 kV and a DC output potential of 400 V at a current up to 25 A. This power converter is also required to be sufficiently compact and reliable to fit and operate within the confines of a high-pressure case to be lowered to several miles (approx.5 km) below the surface of the ocean. The architecture chosen to satisfy these requirements calls for a series/ parallel arrangement of 48 high-frequency, pulse-width-modulation (PWM), transformer-isolation DC-to-DC power converter blocks. The input sides of the converter blocks would be connected in series so that the input potential would be divided among them, each of them being exposed to an input potential of no more than 10 kV/48 . 210 V. The series connection of inputs would also enforce a requirement that all the converter blocks operate at the same input current. The outputs of the converter blocks would be connected in a matrix comprising 6 parallel legs, each leg being a cascade of eight outputs wired in series (see figure). All the converter blocks would be identical within the tolerances of the values of their components. A single voltage feedback loop would regulate the output potential. All the converter blocks would be driven by the same PWM waveform generated by this feedback loop. The power transformer of each converter block would have a unity turns ratio and would be capable of withstanding as much as 10 kVDC between its primary and secondary windings. (Although, in general, the turns ratio could be different from unity, the simplest construction for minimizing leakage and maximizing breakdown voltage is attained at a turns ratio of unity.)

  4. Advanced power cycling test for power module with on-line on-state VCE measurement

    DEFF Research Database (Denmark)

    Choi, Ui-min; Trintis, Ionut; Blaabjerg, Frede

    2015-01-01

    estimation of power semiconductor devices and capacitors have been done. Accelerated power cycling test is one of the common tests to assess the power device module and develop the lifetime model considering the physics of failure. In this paper, a new advanced power cycling test setup is proposed for power......Recent research has made an effort to improve the reliability of power electronic systems to comply with more stringent constraints on cost, safety, predicted lifetime and availability in many applications. For this, studies about failure mechanisms of power electronic components and lifetime...... module. The proposed concept can perform various stress conditions which is valid in a real mission profile and it is using a real power converter application with small loss. The concept of the proposed test setup is first presented. Then, the on-line on-state collector-emitter voltage VCE measurement...

  5. A Novel High-Frequency Voltage Standing-Wave Ratio-Based Grounding Electrode Line Fault Supervision in Ultra-High Voltage DC Transmission Systems

    Directory of Open Access Journals (Sweden)

    Yufei Teng

    2017-03-01

    Full Text Available In order to improve the fault monitoring performance of grounding electrode lines in ultra-high voltage DC (UHVDC transmission systems, a novel fault monitoring approach based on the high-frequency voltage standing-wave ratio (VSWR is proposed in this paper. The VSWR is defined considering a lossless transmission line, and the characteristics of the VSWR under different conditions are analyzed. It is shown that the VSWR equals 1 when the terminal resistance completely matches the characteristic impedance of the line, and when a short circuit fault occurs on the grounding electrode line, the VSWR will be greater than 1. The VSWR will approach positive infinity under metallic earth fault conditions, whereas the VSWR in non-metallic earth faults will be smaller. Based on these analytical results, a fault supervision criterion is formulated. The effectiveness of the proposed VSWR-based fault supervision technique is verified with a typical UHVDC project established in Power Systems Computer Aided Design/Electromagnetic Transients including DC(PSCAD/EMTDC. Simulation results indicate that the proposed strategy can reliably identify the grounding electrode line fault and has strong anti-fault resistance capability.

  6. A Dynamic Consensus Algorithm based Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive Microgrids

    DEFF Research Database (Denmark)

    Zhao, Xin; Meng, Lexuan; Savaghebi, Mehdi

    2016-01-01

    The possibility of increasing penetration level of grid-interactive microgrids (MGs) has gained a great interest over the past decade. Thus, it is critical to investigate the performance of the MGs under voltage sags, since it may induce instability to the power grid. Negative sequence droop...... control based voltage support strategy has been proposed to aid MGs riding through three phase asymmetrical voltage sags. However, since the line impedance from each converter to the point of common coupling (PCC) is not identical, both positive sequence and negative sequence output current...

  7. Power conditioning using dynamic voltage restorers under different voltage sag types

    Directory of Open Access Journals (Sweden)

    Ahmed M. Saeed

    2016-01-01

    Full Text Available Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs. By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  8. Power conditioning using dynamic voltage restorers under different voltage sag types.

    Science.gov (United States)

    Saeed, Ahmed M; Abdel Aleem, Shady H E; Ibrahim, Ahmed M; Balci, Murat E; El-Zahab, Essam E A

    2016-01-01

    Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs). By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  9. An algorithm for reduction of extracted power from photovoltaic strings in grid-tied photovoltaic power plants during voltage sags

    DEFF Research Database (Denmark)

    Tafti, Hossein Dehghani; Maswood, Ali Iftekhar; Pou, Josep

    2016-01-01

    , the injected active power should be reduced during voltage sags. In order to obtain a constant dc-link voltage in a multi-string PVPP, the extracted power from PV strings should be equal to the injected power to the grid in all operating conditions (excluding power losses). Therefore, the extracted power of PV...... strings should be reduced during voltage sags. In this paper, an algorithm is proposed for determining the reference voltage of the PV string which results in a reduction of the output power to a certain amount. The proposed algorithm calculates the reference voltage for the dc/dc converter controller......, based on the characteristics of the power-voltage curve of the PV string and therefore, no modification is required in the the controller of the dc/dc converter. Simulation results on a 50-kW PV string verified the effectiveness of the proposed algorithm in reducing the power from PV strings under...

  10. Determination of appropriate DC voltage for switched mode power supply (SMPS) loads

    Science.gov (United States)

    Setiawan, Eko Adhi; Setiawan, Aiman; Purnomo, Andri; Djamal, Muchlishah Hadi

    2017-03-01

    Nowadays, most of modern and efficient household electronic devices operated based on Switched Mode Power Supply (SMPS) technology which convert AC voltage from the grid to DC voltage. Based on theory and experiment, SMPS loads could be supplied by DC voltage. However, the DC voltage rating to energize electronic home appliances is not standardized yet. This paper proposed certain method to determine appropriate DC voltage, and investigated comparison of SMPS power consumption which is supplied from AC and DC voltage. To determine the appropriate DC voltage, lux value of several lamps which have same specification energized by using AC voltage and the results is using as reference. Then, the lamps were supplied by various DC voltage to obtain the trends of the lux value to the applied DC voltage. After that, by using the trends and the reference lux value, the appropriate DC voltage can be determined. Furthermore, the power consumption on home appliances such as mobile phone, laptop and personal computer by using AC voltage and the appropriate DC voltage were conducted. The results show that the total power consumption of AC system is higher than DC system. The total power (apparent power) consumed by the lamp, mobile phone and personal computer which operated in 220 VAC were 6.93 VA, 34.31 VA and 105.85 VA respectively. On the other hand, under 277 VDC the load consumption were 5.83 W, 19.11 W and 74.46 W respectively.

  11. Power Quality Improvement And Mitigation Of Voltage Sag And Current Swell Using Distributed Power Flow Controller

    OpenAIRE

    P. Nirmala; SK.SAJIDA

    2014-01-01

    Modern power utilities have to respond to a number of challenges such as growth of electricity demand specially in non-linear loads in power grids, consequently, That higher power quality should be considered. In this paper, DPFC which is similar to unified power flow controller (UPFC) in structure, which is used to mitigate the voltage sag and swell as a power quality issue. Unlike UPFC, the common dc-link in DPFC, between the shunt and series converter devices should be eliminated and three...

  12. Mathematical models of lightning-induced voltages in transmission lines in a permafrost region

    Science.gov (United States)

    Grigor'ev, Yuri M.; Borisova, Marpha N.; Longinova, Viktoriya Ya.; Ivanova, Anna A.

    2017-11-01

    Lightning induced voltages in transmission lines consist of electromagnetic and electrostatic components. The electrostatic component is much less than electromagnetic one in regions where soils have a high electrical conductivity. In this paper we present mathematical models of the electrostatic component of lightning induced voltages in transmissions lines in a permafrost region where soils have a low electrical conductivity. Numerical simulations show that the values of the electrostatic component is comparable to electromagnetic one in a permafrost region.

  13. Application of Voltage-regulating and Phaseshifting Transformers to Control Power Flows in the Power System

    Directory of Open Access Journals (Sweden)

    Maksymilian Przygrodzki

    2015-12-01

    Full Text Available Transmission system performance results from, among other factors, the use of devices for electricity transmission and transformation. Proper operation and control of these devices allows maintaining proper electricity parameters and the continuous supply to end consumers. In the group of electricity transforming devices transformers can be distinguished by the ability to control both the magnitude and phase angle of voltage. In this way transmission system state parameters are adjusted, which enable selecting the reactive and active power. On the one hand, these are devices of a complex structure, resulting in difficult operating conditions, while on the other hand they provide a potential opportunity to influence the power flow (including active power in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.active power in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.

  14. Evaluation of Silicone Rubber Insulators used in High-Voltage Transmission Lines

    Science.gov (United States)

    Ul-Hamid, Anwar; Soufi, Khaled Y.; Al-Hamoudi, Ibrahim

    2008-04-01

    Three long-rod silicone rubber composite insulators used in 230 kV power transmission lines were evaluated for aging affects. The insulators were obtained from various outdoor desert locations within Saudi Arabia where they had been in service for 6 years. Surface degradation associated with the aging process was analyzed by using Scanning Electron Microscopy (SEM) coupled with Energy Dispersive X-ray Spectroscopy (EDS), Fourier Transform Infra-Red Spectroscopy (FTIR), and Electron Spectroscopy for Chemical Analysis (ESCA). Electrical performance of insulators was evaluated by Rapid Flashover Voltage Tests (RFVT) and Pollution Severity Measurement Tests. Depending on their locations of service, the samples exhibited various types of pollutants at their surfaces. The analysis indicated that the insulator material showed localized surface degradation while there was no evidence of micro-cracking. Furthermore, it was noted that the electrical performance of the insulators was not significantly affected by exposure during the in-service period.

  15. Overhead high-voltage lines - a electromagnetic environment restrictions on use areas

    Directory of Open Access Journals (Sweden)

    Jacek Paś

    2014-09-01

    Full Text Available The paper presents the influence of exploitation of high voltage overhead lines in the vicinity of the lands that are intended for built-up areas. Near distribution stations and high voltage overhead lines can be present some physical and chemical factors which under certain conditions and at their high levels will be inconvenient to the environment. The environmental impacts of these factors are complex problems which are analysed both in technical and biological-medical aspects. [b]Keywords[/b]: overhead lines, electric field and magnetic, lines of force

  16. Location of Faults in Power Transmission Lines Using the ARIMA Method

    OpenAIRE

    Danilo Pinto Moreira de Souza; Eliane da Silva Christo; Aryfrance Rocha Almeida

    2017-01-01

    One of the major problems in transmission lines is the occurrence of failures that affect the quality of the electric power supplied, as the exact localization of the fault must be known for correction. In order to streamline the work of maintenance teams and standardize services, this paper proposes a method of locating faults in power transmission lines by analyzing the voltage oscillographic signals extracted at the line monitoring terminals. The developed method relates time series models...

  17. Extension of the Accurate Voltage-Sag Fault Location Method in Electrical Power Distribution Systems

    Directory of Open Access Journals (Sweden)

    Youssef Menchafou

    2016-03-01

    Full Text Available Accurate Fault location in an Electric Power Distribution System (EPDS is important in maintaining system reliability. Several methods have been proposed in the past. However, the performances of these methods either show to be inefficient or are a function of the fault type (Fault Classification, because they require the use of an appropriate algorithm for each fault type. In contrast to traditional approaches, an accurate impedance-based Fault Location (FL method is presented in this paper. It is based on the voltage-sag calculation between two measurement points chosen carefully from the available strategic measurement points of the line, network topology and current measurements at substation. The effectiveness and the accuracy of the proposed technique are demonstrated for different fault types using a radial power flow system. The test results are achieved from the numerical simulation using the data of a distribution line recognized in the literature.

  18. Real Time Voltage and Current Phase Shift Analyzer for Power Saving Applications

    Directory of Open Access Journals (Sweden)

    Ondrej Krejcar

    2012-08-01

    Full Text Available Nowadays, high importance is given to low energy devices (such as refrigerators, deep-freezers, washing machines, pumps, etc. that are able to produce reactive power in power lines which can be optimized (reduced. Reactive power is the main component which overloads power lines and brings excessive thermal stress to conductors. If the reactive power is optimized, it can significantly lower the electricity consumption (from 10 to 30%—varies between countries. This paper will examine and discuss the development of a measuring device for analyzing reactive power. However, the main problem is the precise real time measurement of the input and output voltage and current. Such quality measurement is needed to allow adequate action intervention (feedback which reduces or fully compensates reactive power. Several other issues, such as the accuracy and measurement speed, must be examined while designing this device. The price and the size of the final product need to remain low as they are the two important parameters of this solution.

  19. Research on the Voltage Fluctuation Rules of Power System Containing Wind Farms

    Science.gov (United States)

    Chen, Yixi; Xu, Guchao; Ma, Gang; Li, Feng; Ju, Rong

    2017-05-01

    The global energy shortage and environmental problems have contributed to the rapid development of wind power. However, due to the randomness and volatility of wind power, large-scale access may cause voltage fluctuation in power grid. Therefore, the reactive power control of power system containing wind farms has become a hot research topic in recent years, in which finding key nodes of voltage fluctuation is a foundation work. In this paper, the power model of wind farm is established first. Then, the influence on nodes voltage when wind farms access simple power system is analysed, and promoted to complex power systems in order to reveal the fluctuation rules of nodes voltage, and to summarize the distribution characteristics of key nodes of voltage fluctuation, which can provide the basis for reactive power optimization. At last, the conclusions are verified by IEEE 30-node system.

  20. A high voltage pulsed power supply for capillary discharge waveguide applications

    Science.gov (United States)

    Abuazoum, S.; Wiggins, S. M.; Issac, R. C.; Welsh, G. H.; Vieux, G.; Ganciu, M.; Jaroszynski, D. A.

    2011-06-01

    We present an all solid-state, high voltage pulsed power supply for inducing stable plasma formation (density ˜1018 cm-3) in gas-filled capillary discharge waveguides. The pulser (pulse duration of 1 μs) is based on transistor switching and wound transmission line transformer technology. For a capillary of length 40 mm and diameter 265 μm and gas backing pressure of 100 mbar, a fast voltage pulse risetime of 95 ns initiates breakdown at 13 kV along the capillary. A peak current of ˜280 A indicates near complete ionization, and the r.m.s. temporal jitter in the current pulse is only 4 ns. Temporally stable plasma formation is crucial for deploying capillary waveguides as plasma channels in laser-plasma interaction experiments, such as the laser wakefield accelerator.

  1. Phase-angle jump during voltage dips in wind power installations

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Lazaro, E.; Canas, M.; Pujante, A.J. [Universidad de Castilla-La Mancha, Albacete (Spain). Renewable Energy Research Inst. and Dept. of Electrical, Electronic and Control Engineering; Fuentes, J.A.; Molina-Garcia, A. [Universidad Politecnica de Cartagena (Spain). Dept. of Electrical Engineering

    2008-07-01

    A voltage dip is a disturbance in the power system that consists in a sudden reduction of voltage level and a recovery in a short period of time, the magnitude and angle of the voltage phasors can be affected by this disturbance. The variation between the pre-fault voltage phasor angle and dip voltage phasor angle is called phase-angle jump. In this paper, it is carried out a study of the characteristics of real voltage dips. The study highlights the phase-angle jumps that appear on voltage dips, analyzing the influence of the voltage dip type, depth or length. Voltage dips have been acquired with power quality analyzers with a 10 MHz sample rate in a Spanish wind farm for 18 months. (orig.)

  2. Voltage measurements at the vacuum post-hole convolute of the Z pulsed-power accelerator

    Directory of Open Access Journals (Sweden)

    E. M. Waisman

    2014-12-01

    Full Text Available Presented are voltage measurements taken near the load region on the Z pulsed-power accelerator using an inductive voltage monitor (IVM. Specifically, the IVM was connected to, and thus monitored the voltage at, the bottom level of the accelerator’s vacuum double post-hole convolute. Additional voltage and current measurements were taken at the accelerator’s vacuum-insulator stack (at a radius of 1.6 m by using standard D-dot and B-dot probes, respectively. During postprocessing, the measurements taken at the stack were translated to the location of the IVM measurements by using a lossless propagation model of the Z accelerator’s magnetically insulated transmission lines (MITLs and a lumped inductor model of the vacuum post-hole convolute. Across a wide variety of experiments conducted on the Z accelerator, the voltage histories obtained from the IVM and the lossless propagation technique agree well in overall shape and magnitude. However, large-amplitude, high-frequency oscillations are more pronounced in the IVM records. It is unclear whether these larger oscillations represent true voltage oscillations at the convolute or if they are due to noise pickup and/or transit-time effects and other resonant modes in the IVM. Results using a transit-time-correction technique and Fourier analysis support the latter. Regardless of which interpretation is correct, both true voltage oscillations and the excitement of resonant modes could be the result of transient electrical breakdowns in the post-hole convolute, though more information is required to determine definitively if such breakdowns occurred. Despite the larger oscillations in the IVM records, the general agreement found between the lossless propagation results and the results of the IVM shows that large voltages are transmitted efficiently through the MITLs on Z. These results are complementary to previous studies [R. D. McBride et al., Phys. Rev. ST Accel. Beams 13, 120401 (2010

  3. Application of Load Compensation in Voltage Controllers of Large Generators in the Polish Power Grid

    Directory of Open Access Journals (Sweden)

    Bogdan Sobczak

    2014-03-01

    Full Text Available The Automatic Voltage Regulator normally controls the generator stator terminal voltage. Load compensation is used to control the voltage which is representative of the voltage at a point either within or external to the generator. In the Polish Power Grid (PPG compensation is ready to use in every AVR of a large generator, but it is utilized only in the case of generators operating at the same medium voltage buses. It is similar as in most European Power Grids. The compensator regulating the voltage at a point beyond the machine terminals has significant advantages in comparison to the slower secondary Voltage and Reactive Power Control System (ARNE1. The compensation stiffens the EHV grid, which leads to improved voltage quality in the distribution grid. This effect may be particularly important in the context of the dynamic development of wind and solar energy.

  4. New overhead lines are required for the land - and Europe. The new regulation of the TEN-E regulations and their consequences for the Germann planning law and licensing law for high-voltage power lines under special consideration of the regulations of the public relations; Neue Leitungen braucht das Land - und Europa. Die Neuregelung der TEN-E-Leitlinien und deren Konsequenzen fuer das deutsche Planungs- und Genehmigungsrecht fuer Hoechstspannungsleitungen unter besonderer Beruecksichtigung der Vorschriften ueber die Oeffentlichkeitsbeteiligung

    Energy Technology Data Exchange (ETDEWEB)

    Schadtle, Kai [Stuttgart Univ. (Germany). Abt. fuer Rechtswissenschaft

    2013-05-15

    The German energy policy turnaround requires an optimization of the energy infrastructure. The energy policy objectives of the European Union with respect to competitiveness, security of supply and sustainability require a rapid expansion and transformation of the European energy infrastructure. Under this aspect, the author of the contribution under consideration reports on the revision of the TEN-E guidelines and their consequences for the German planning law and licensing law for high-voltage power lines with special consideration of the rules of the public relations. The national legal framework for the development of the German transmission system and the design of the new TEN-E guidelines for the trans-European network development are presented.

  5. Fault Location in Power Electrical Traction Line System

    Directory of Open Access Journals (Sweden)

    Yimin Zhou

    2012-11-01

    Full Text Available In this paper, methods of fault location are discussed in electrical traction single-end direct power supply network systems. Based on the distributed parameter model of the system, the position of the short-circuit fault can be located with the aid of the current and voltage value at the measurement end of the electrical traction line. Furthermore, the influence of the transient resistance, the position of the locomotive, locomotive load for fault location are also discussed. MATLAB simulation tool is used for the simulation experiments. Simulation results are proved the effectiveness of the proposed algorithms.

  6. Voltage regulator for battery power source. [using a bipolar transistor

    Science.gov (United States)

    Black, J. M. (Inventor)

    1979-01-01

    A bipolar transistor in series with the battery as the control element also in series with a zener diode and a resistor is used to maintain a predetermined voltage until the battery voltage decays to very nearly the predetermined voltage. A field effect transistor between the base of the bipolar transistor and a junction between the zener diode and resistor regulates base current of the bipolar transistor, thereby regulating the conductivity of the bipolar transistor for control of the output voltage.

  7. A Novel Design of Radio Frequency Energy Relays on Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Jin Tong

    2016-06-01

    Full Text Available In this paper, we investigate the energy problem of monitoring sensors on high-voltage power transmission lines and propose a wireless charging scheme for a Radio Frequency IDentification (RFID sensor tag to solve a commercial efficiency problem: the maintenance-caused power outage. Considering the environmental influences on power transmission lines, a self-powered wireless energy relay is designed to meet the energy requirement of the passive RFID sensor tag. The relay can obtain the electric field energy from the transmission lines and wirelessly power the RFID sensor tags around for longer operating distance. A prototype of the energy relay is built and tested on a 110 kv line. The measurement results show that the energy relay can provide stable energy even with the influences of wind, noise and power outage. To our knowledge, it is the first work to power the RFID sensor tags on power transmission lines.

  8. The effects of lightning and high altitude electromagnetic pulse on power distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Uman, M.A.; Rubinstein, M.; Yacoub, Z. [Florida Univ., Gainesville, FL (United States)

    1995-01-01

    We simultaneously recorded the voltages induced by lightning on both ends of an unenergized 448-meter long unenergized electric power line and the lightning vertical electric and horizontal magnetic fields at ground level near the line. The lightning data studied and presented here were due both to cloud lightning and to very close (about 20 m from the line) artificially initiated lightning. For cloud sources, a frequency-domain computer program called EMPLIN was used to calculate induced line voltages as a function of source elevation, angle of incidence, and wave polarization of the radiated cloud discharge pulses in order to compare with the measurements. For very-close lightning, the measured line voltages could be grouped into two categories, those in which multiple, similarly shaped, evenly spaced pulses were observed, which we call oscillatory, and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which we call impulsive. The amplitude of the induced voltage ranged from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages. A new technique is derived for the calculation of the electromagnetic fields from nearby lightning to ground above an imperfectly conducting ground. This technique was used in conjunction with an existing time domain coupling theory and lightning return stroke model to calculate voltages at either end of the line. The results show fair agreement with the measured oscillatory voltage waveforms if corona is ignored and improved results when corona effects are modeled. The modeling of the impulsive voltage, for which local flashover probably successful. In an attempt to understand better the sources of the line voltages for very close lightning, measurements of the horizontal and vertical electric fields 30 m from triggered lightning were obtained.

  9. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation

    OpenAIRE

    Hojong Choi; Park Chul Woo; Jung-Yeol Yeom; Changhan Yoon

    2017-01-01

    A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reduci...

  10. Autonomous SEIG in a small wind power plant with voltage and frequency control

    Directory of Open Access Journals (Sweden)

    Benlamoudi Azzeddine

    2012-01-01

    Full Text Available This paper deals with the application of an autonomous Self-Excited Induction Generator (SEIG in a small wind power conversion system (WPCS. Such conversion system has capability to supply power demand of the loads with constant voltage and frequency, for which a power managing method is proposed. Voltage Sourced Converter (VSC along with Battery Energy Storage System (BESS is used to handle power flow between the SEIG and loads. The proposed control scheme, using a single voltage closed-loop control, is found to be suitable to regulate both voltage and frequency. The WPCS is modelled in MATLAB/Simulink and Power System Block-set (PSB. Simulation results show that Voltage Frequency Controller (VFC has ability to keep the voltage and frequency constant in spite of perturbations.

  11. SEMICONDUCTOR DEVICES: A novel high voltage start up circuit for an integrated switched mode power supply

    Science.gov (United States)

    Hao, Hu; Xingbi, Chen

    2010-09-01

    A novel high voltage start up circuit for providing an initial bias voltage to an integrated switched mode power supply (SMPS) is presented. An enhanced mode VDMOS transistor, the gate of which is biased by a floating p-island, is used to provide start up current and sustain high voltage. An NMOS transistor having a high source to ground breakdown voltage is included to extend the bias voltage range to the SMPS. Simulation results indicate that the high voltage start up circuit can start and restart as designed. The proposed structure is believed to be more energy saving and cost-effective compared with other solutions.

  12. Influence of the Topography in the Calculation of Lightning Induced Voltages on Overhead Lines

    OpenAIRE

    Soto, Edison,; Pérez, Ernesto,

    2016-01-01

    International audience; Lightning has been an important cause of failure of electrical facilities. Its effects are counted as outage of transmission and distribution lines around the world [1][2]. In the case of transmission lines, the direct strikes to tower or ground wires cause back flashover on insulation chains [3][4]. On distribution networks the main affectation is due to indirect impacts that can induce voltages higher than the insulation level of this kind of lines. The high frequenc...

  13. Study on Optimization Strategy for Voltage and Reactive Power Control of Wind Farm

    Science.gov (United States)

    Lu, Q.; Shi, L.; Chen, N.

    A method for calculating reactive power limit of wind farm comprised of doubly-fed induction generators (DFIG) is proposed. The reactive power limit of wind farm is the sum of reactive power limit of DFIGs which is calculated by the method considering static stability margin. Based on this, reactive power control of wind farm is discussed and proposed. The proposed reactive power control is divided into different control modes according to power factor of high voltage side in wind farm substation and voltage of low voltage side in point of interconnection(POI). In different control modes, different control objects are applied on reactive power regulation. After reactive power regulation is finished, some reactive power of wind farm should be released. At last, numerical test system is established, the result shows that the proposed method is effective to support voltage of POI

  14. Does the expansion of German high voltage power supply system imply health risks?; Geht vom Ausbau elektrischer Hochspannungsleitungen eine Gefahr fuer die menschliche Gesundheit aus?

    Energy Technology Data Exchange (ETDEWEB)

    Kappos, Andreas D.

    2016-07-01

    The decision of the German parliament to gradually close down nuclear power plants mainly located in the south of Germany and to support wind farms in the North Sea mud flats as the dominant regenerative energy source requires the strengthening and enlargement of the power supply system with the installation of new long distance high voltage power lines. The legally fixed dimension and formality of the actual planning process are discussed as well as the legal regulations for the protection of human health. Guided by the assessment of IARC a ''possible'' carcinogenic effect of low frequency electromagnetic fields on people living in the vicinity of high voltage power lines has to be considered. Therefore from a preventive viewpoint the minimal distance of 400 m between newly planned high voltage power lines and human settlements required by law seem justified.

  15. Identification of voltage stability condition of a power system using measurements of bus variables

    Directory of Open Access Journals (Sweden)

    Durlav Hazarika

    2014-12-01

    Full Text Available Several online methods were proposed for investigating the voltage stability condition of an interconnected power system using the measurements of voltage and current phasors at a bus. For this purpose, phasor measurement units (PMUs are used. A PMU is a device which measures the electrical waves on an electrical network, using a common time source (reference bus for synchronisation. This study proposes a method for online monitoring of voltage stability condition of a power system using measurements of bus variables namely – (i real power, (ii reactive power and (iii bus voltage magnitude at a bus. The measurements of real power, reactive power and bus voltage magnitude could be extracted/captured from a smart energy meter. The financial involvement for implementation of the proposed method would significantly lower compared with the PMU-based method.

  16. A Sepic-Type Single-Stage Electronic Ballast for High Line Voltage Applications

    Science.gov (United States)

    Shen, Chih-Lung; Chen, Kuo-Kuang

    In this paper, a sepic-type single-stage electronic ballast (STSSEB) is proposed, which is derived from the combination of a sepic converter and a half-bridge inverter. The ballast can not only step down input voltage directly but achieve high power factor, reduce voltage stress, improve efficiency and lower cost. Since component stress is reduced significantly, the presented ballast can be applied to high voltage mains. Derivation of the STSSEB is first presented. Then, analysis, design and practical consideration for the STSSEB are discussed. A 347Vac 60W prototype has been simulated and implemented. Simulations and experimental results have verified the feasibility of the proposed STSSEB.

  17. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    OpenAIRE

    Yong-Nong, C.; K. Chih-Ming

    2013-01-01

    In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The power supply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to the indispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer need considering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, but also parasitic capacitance resulted fr...

  18. Electric Field Simulations and Analysis for High Voltage High Power Medium Frequency Transformer

    Directory of Open Access Journals (Sweden)

    Pei Huang

    2017-03-01

    Full Text Available The electronic power transformer (EPT raises concerns for its notable size and volume reduction compared with traditional line frequency transformers. Medium frequency transformers (MFTs are important components in high voltage and high power energy conversion systems such as EPTs. High voltage and high power make the reliable insulation design of MFT more difficult. In this paper, the influence of wire type and interleaved winding structure on the electric field distribution of MFT is discussed in detail. The electric field distributions for six kinds of typical non-interleaved windings with different wire types are researched using a 2-D finite element method (FEM. The electric field distributions for one non-interleaved winding and two interleaved windings are also studied using 2-D FEM. Furthermore, the maximum electric field intensities are obtained and compared. The results show that, in this case study, compared with foil conductor, smaller maximum electric field intensity can be achieved using litz wire in secondary winding. Besides, interleaving can increase the maximum electric field intensity when insulation distance is constant. The proposed method of studying the electric field distribution and analysis results are expected to make a contribution to the improvement of electric field distribution in transformers.

  19. OPC Server and BridgeView Application for High Voltage Power Supply Lecroy 1458

    CERN Document Server

    Swoboda, D; CERN. Geneva

    2000-01-01

    Abstract The aim of this project was to develop an OPC server to communicate over an RS232 serial line. This communication media is commonly used with commercial instruments. The development was made for a High Voltage power supply in the context of the Alice [1] experiment. In addition, the structured modular concept will allow changing the transmission media or power supply type with little effort. The high voltage power supply should be accessible remotely through a network. OPC[2] is an acronym for OLE[3] for Process Control. OPC is based on the DCOM [3] communication protocol, which allows communication with any computer running a Windows based OS. This standard is widely used in industry to access device data through Windows applications. The concept is based on the client-server architecture. The hardware and the software architecture are described. Subsequently details of the implemented programs are given with emphasis on the possibility to replace parts of the software in order to use differ...

  20. A single-stage voltage sensorless power factor correction converter for LED lamp driver

    Directory of Open Access Journals (Sweden)

    Mahmoud S. Abd El-Moniem

    2013-12-01

    Full Text Available Light-emitting diode (LED technology presents an effective and robust solution to decrease the energy demand. In this paper, a power factor correction (PFC converter is proposed to solve the problems that appear when using LED lamps, such as reducing harmonic currents and reshaping the input current to be a sinusoidal waveform without using line voltage sensor, so the total cost can be reduced and increasing the efficiency. Thus, this technique is considered a simple and easy method which reduces the number of sensors required and achieves the noise isolation between the power circuit and the controller. Also, the proposed method is implemented using a zero-crossing processing, which allows a greater accuracy than other methods. Simulation and experimental results demonstrate the effectiveness and feasibility of the proposed circuit which show that the proposed control method has low inrush input current, high power factor (near unity, and fast dynamic response under transient operation. Also, a sinusoidal current waveform under a non-sinusoidal input voltage condition can be achieved.

  1. A Grid-Voltage-Sensorless Resistive Active Power Filter with Series LC-Filter

    DEFF Research Database (Denmark)

    Bai, Haofeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    Voltage-sensorless control has been investigated for Voltage Source Inverters (VSIs) for many years due to the reduced system cost and potentially improved system reliability. The VSI based Resistive Active Power Filters (R-APFs) are now widely used to prevent the harmonic resonance in power...

  2. Analog IC techniques for low-voltage low-power electronics

    NARCIS (Netherlands)

    Serdijn, W.A.; Verhoeven, C.J.M.; Van Roermund, A.H.M.

    1995-01-01

    Analog IC Techniques lor Low-Voltage Low Power Electronics addresses many very important, but recent, techniques which enable electronics to operate at a low supply voltage and consume a minimum amount of power. Apart from investigations at the device, circuit and system levels, the book provides a

  3. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....

  4. An Integrated Chip High-Voltage Power Receiver for Wireless Biomedical Implants

    Directory of Open Access Journals (Sweden)

    Vijith Vijayakumaran Nair

    2015-06-01

    Full Text Available In near-field wireless-powered biomedical implants, the receiver voltage largely overrides the compliance of low-voltage power receiver systems. To limit the induced voltage, generally, low-voltage topologies utilize limiter circuits, voltage clippers or shunt regulators, which are power-inefficient methods. In order to overcome the voltage limitation and improve power efficiency, we propose an integrated chip high-voltage power receiver based on the step down approach. The topology accommodates voltages as high as 30 V and comprises a high-voltage semi-active rectifier, a voltage reference generator and a series regulator. Further, a battery management circuit that enables safe and reliable implant battery charging based on analog control is proposed and realized. The power receiver is fabricated in 0.35-μm high-voltage Bipolar-CMOS-DMOStechnology based on the LOCOS0.35-μm CMOS process. Measurement results indicate 83.5% power conversion efficiency for a rectifier at 2.1 mA load current. The low drop-out regulator based on the current buffer compensation and buffer impedance attenuation scheme operates with low quiescent current, reduces the power consumption and provides good stability. The topology also provides good power supply rejection, which is adequate for the design application. Measurement results indicate regulator output of 4 ± 0.03 V for input from 5 to 30 V and 10 ± 0.05 V output for input from 11 to 30 V with load current 0.01–100 mA. The charger circuit manages the charging of the Li-ion battery through all if the typical stages of the Li-ion battery charging profile.

  5. Reactive Power Strategy of Cascaded Delta-connected STATCOM Under Asymmetrical Voltage Conditions

    DEFF Research Database (Denmark)

    He, Zhixing; Ma, Fujun; Xu, Qianming

    2017-01-01

    Cascaded static synchronous compensator (STATCOM) is an effective solution for reactive power support in mid-dle/high voltage conditions, and it has been widely employed to control reactive power in photovoltaic (PV) plants, wind farms, and industrial occasions. In this paper, reactive power...... control strategy of cascaded delta-connected STATCOM under asym-metrical voltage conditions is investigated. A new phase current reference calculation method is proposed to support reactive power continually under abnormal voltage conditions considering cluster voltage balancing control and phase current...... of the phase current references. Furthermore, the reactive power support capability of cascaded STATCOM under asymmetrical voltage conditions is explored and compared by combining the proposed references calculation method with the three generalized current references calculation strategies. Finally...

  6. An Enhanced Power Sharing Scheme for Voltage unbalance and harmonics compensation in an islanded AC microgrid

    DEFF Research Database (Denmark)

    Han, Yang; Shen, Pan; Zhao, Xin

    2016-01-01

    controllers, the selective virtual impedance loop, the unbalance and harmonics compensators, the secondary control for voltage amplitude and frequency restoration, and the auxiliary control to achieve a high voltage quality at the point of common coupling (PCC). By using the proposed unbalance and harmonics......In this paper, an enhanced hierarchical control structure with multiple current loop damping schemes for voltage unbalance and harmonics compensation in ac islanded microgrid is proposed to address unequal power sharing problems. The distributed generation (DG) is properly controlled...... to autonomously compensate voltage unbalance and harmonics while sharing the compensation effort for the real power, reactive power, unbalance and harmonic powers. The proposed control system of the microgrid mainly consists of the positive sequence real and reactive power droop controllers, voltage and current...

  7. High-Voltage, High-Power Gaseous Electronics Switch For Electric Grid Power Conversion

    Science.gov (United States)

    Sommerer, Timothy J.

    2014-05-01

    We are developing a high-voltage, high-power gas switch for use in low-cost power conversion terminals on the electric power grid. Direct-current (dc) power transmission has many advantages over alternating current (ac) transmission, but at present the high cost of ac-dc power interconversion limits the use of dc. The gas switch we are developing conducts current through a magnetized cold cathode plasma in hydrogen or helium to reach practical current densities > 1 A/cm2. Thermal and sputter damage of the cathode by the incident ion flux is a major technical risk, and is being addressed through use of a ``self-healing'' liquid metal cathode (eg, gallium). Plasma conditions and cathode sputtering loss are estimated by analyzing plasma spectral emission. A particle-in-cell plasma model is used to understand various aspects of switch operation, including the conduction phase (where plasma densities can exceed 1013 cm-3), the switch-open phase (where the high-voltage must be held against gas breakdown on the left side of Paschen's curve), and the switching transitions (especially the opening process, which is initiated by forming an ion-matrix sheath adjacent to a control grid). The information, data, or work presented herein was funded in part by the Advanced Research Projects Agency-Energy (ARPA-E), U.S. Department of Energy, under Award Number DE-AR0000298.

  8. Design and Analysis of a Slope Voltage Control for a DFIG Wind Power Plant

    DEFF Research Database (Denmark)

    Martínez, J.; Kjær, P. C.; Rodriguez, Pedro

    2012-01-01

    response to grid disturbances, despite the communication delays, i.e., this concept is based on a primary voltage control, located in the wind turbine, which follows an external voltage reference sent by a central controller, called secondary voltage control, which is controlling the voltage at the point......This paper addresses a detailed design of a wind power plant and turbine slope voltage control in the presence of communication delays for a wide short-circuit ratio range operation. The implemented voltage control scheme is based upon the secondary voltage control concept, which offers fast...... requirements. The results show that fast response to grid disturbances can be achieved using the secondary voltage control scheme, and the fulfillment of the design requirements can be extended for a wide range of short-circuit ratios....

  9. Comprehensive Reactive Power Support of DFIG Adapted to Different Depth of Voltage Sags

    Directory of Open Access Journals (Sweden)

    Yangwu Shen

    2017-06-01

    Full Text Available The low voltage ride-through (LVRT capability of the doubly-fed induction generator (DFIG significantly impacts upon the integration of wind power into the power grid. This paper develops a novel comprehensive control strategy to enhance the LVRT and reactive power support capacities of the DFIG by installing the energy storage system (ESS. The ESS is connected to the DC-link capacitor of the DFIG and used to regulate the DC-link voltage during normal or fault operations. The unbalanced power between the captured wind power and the power injected to the grid during the transient process is absorbed or compensated by the ESS. The rotor-side converter (RSC is used to control the maximum power production and the grid-side converter (GSC is used to control the reactive power before participating in the voltage support. When the supply voltage continues to drop, the rotor speed is increased by controlling the RSC to realize the LVRT capability and help the GSC further enhance the reactive power support capability. The capacity of the GSC is dedicated to injecting the reactive power to the grid. An auxiliary transient pitch angle controller is proposed to protect the generator’s over speed. Both RSC and GSC act as reactive power sources to further enhance the voltage support capability with serious voltage sags. Simulations based on a single-machine infinite-bus power system verify the effectiveness of the developed comprehensive control strategy.

  10. New device to adjust on load the voltage level at power transformers

    Energy Technology Data Exchange (ETDEWEB)

    Plesca, A. [Gh. Asachi Technical Univ. of Iasi, Iasi (Romania); Licau, M. [SCEONSA, Iasi (Romania)

    2007-07-01

    This paper described a new device designed to provide online step voltage regulation and continuous voltage adjustment. The variable inductance system was built using 2 identical toroidal magnetic cores a single controlled winding designed using a magnetic amplifier principle with a rated power of 800 Va, 2 primary windings, a controlled winding, and a magnetic circuit. A digital relay was used to provide control signals for the driver circuits of power electronic switches and to provide variable inductive reactance. A power unit was designed to control voltage levels for the solid-state switches. The prototype was mounted into a cabinet and provided with power circuits for step voltage adjustment and current transformers. Test conducted with variable resistive loads demonstrated that the device added step voltages in order to maintain voltage levels within admissible limits when secondary voltage forms were lowered. Voltage levels were reduced when the maximum voltage threshold was reached. Waveforms recorded during the tests showed that the new device restored output voltage between admissible limits in less than 200 milliseconds. It was concluded that the device's modular construction will provide greater installation flexibility. 15 refs., 5 figs.

  11. Analytical Model of Rain-Wind Induced Vibration of High-Voltage Transmission Line

    Directory of Open Access Journals (Sweden)

    Chao Zhou

    2014-10-01

    Full Text Available Under rainfall conditions, rain-wind induced vibration occurs on high-voltage transmission line occasionally. This phenomenon is caused by raindrops hitting the high-voltage conductor with a certain velocity and suspends to the bottom surface of the high-voltage conductor. By action of wind velocity and high-voltage conductor's motion, some suspended raindrops will be blown away or shaken off. The remaining water may be reformed as upper rivulet and lower rivulet. Like the effect of icing galloping, this type of vibration can cause metal fatigue on fittings and towers, while its mechanism remains unknown. The objective of this paper is to validate an analytical model of rain-wind induced vibration of the high-voltage transmission line and to investigate the effect of wind velocity, rivulet motion, raindrop velocity, and time varying mass on the vibration amplitude. Taking Tuo-chang transmission line as an example, the analytical model is solved by Galerkin weighted residual method and central difference method. The numerical results are in agreement with the experimental data available in the literature. The analytical model enables more comprehensive understanding of the rain-wind induced vibration mechanism.

  12. A New Coordinated Voltage Control Scheme for Offshore AC Grid of HVDC Connected Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Cutululis, Nicolaos Antonio; Rather, Zakir Hussain

    2015-01-01

    This paper proposes a coordinated voltage control scheme (CVCS) which enhances the voltage ride through (VRT) capability of an offshore AC grid comprised of a cluster of offshore wind power plants (WPP) connected through AC cables to the offshore voltage source converter based high voltage DC (VS......V with active power balance (hence DC voltage) control assigned to the onshore converter, while frequency and AC voltage control at the offshore substation assigned to the offshore converter....

  13. Experiences in simulating and testing coordinated voltage control provided by multiple wind power plants

    Energy Technology Data Exchange (ETDEWEB)

    Arlaban, T.; Alonso, O.; Ortiz, D. [Acciona Windpower S.A. (Spain); Peiro, J.; Rivas, R. [Red Electrica de Espana SAU (Spain); Quinonez-Varela, G.; Lorenzo, P. [Acciona Energia S.A. (Spain)

    2011-07-01

    This document presents some field tests performed in a transmission system node in order to check the adequacy of voltage control performance by multiple wind power plants, with an overall capacity of 395 MW. It briefly explains the Spanish TSO motivation towards new voltage control requirements and the necessity of performing such tests in order to set the most convenient voltage control parameters and to verify the stable operation. It presents how different the voltage control capability between modern wind turbines (DFIG) and older ones (SCIG) specifically retrofitted for voltage control is. (orig.)

  14. Performance of Doubly-Fed Wind Power Generators During Voltage Dips

    DEFF Research Database (Denmark)

    Aparicio, N.; Chen, Zhe; Beltran, H.

    The growing of wind generation in Spain has forced its Transmission System Operator (TSO) to release new requirements that establish the amount of reactive power that a wind turbine has to supply to the grid during a voltage dip. Wind turbines equipped with doubly-fed induction generators (DFIG......) can regulate easily the reactive power generated in steady state. However, difficulties appear when reactive power has to be generated during voltage dips. Simulations have been carried out in order to check whether DFIG wind turbines can fulfill the reactive power requirements. Protection system...... acting as STATCOM helps to improve the voltage profile sufficiently to permit rotor-side converter reconnection....

  15. Distance from residence to power line and risk of childhood leukemia

    DEFF Research Database (Denmark)

    Pedersen, Camilla; Raaschou-Nielsen, Ole; Rod, Naja Hulvej

    2013-01-01

    Epidemiological studies have found an association between exposure to extremely low-frequency magnetic fields (ELF-MF) and childhood leukemia. In 2005, a large British study showed an association between proximity of residence to high-voltage power lines and the risk of childhood leukemia....... The association extended beyond distances at which the 'power line'-induced magnetic fields exceed background levels, suggesting that the association was not explained by the magnetic field, but might be due to chance, bias, or other risk factors associated with proximity to power lines. Our aim was to conduct...

  16. Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation

    OpenAIRE

    Mahmood, Farhan

    2016-01-01

    Lightning can cause flashovers on Medium Voltage (MV) lines from both direct and nearby strikes. The work presented in this dissertation thoroughly investigates the characteristics of lightning-initiated flashover faults, expected overvoltage stress and the performance of different surge protection schemes to mitigate the lightning overvoltages. A full-scale experimental set-up is established to investigate the nature of lightning-initiated flashover faults in MV lines. The flashover volt...

  17. Study of short-time ac flashover voltage of contaminated insulators and a consideration of its application to transmission line insulation design. [500 kV lines

    Energy Technology Data Exchange (ETDEWEB)

    Itabashi, T. (Tokyo Electric Power Co., Inc.); Osada, K.; Seta, T.; Naito, K.

    1976-01-01

    Insulator contamination is the decisive factor in making insulation design of most transmission lines in Japan. The performance of contaminated insulators against a short-time ac overvoltage in the order of several cycles is described, taking into consideration comparatively higher overvoltage due to the one-phase-to-ground fault of recent long-distance bulk power transmission lines with series capacitors. It has been made clear by this study that, in the case of a fault clearance within 0.07 sec, e.g., the flashover voltage increases by about 15% more than in a continuous energization. This implies that the insulation of series-capacitor-compensated lines can be met by the conventional insulation design levels.

  18. Improving the output voltage waveform of an intense electron-beam accelerator based on helical type Blumlein pulse forming line

    Directory of Open Access Journals (Sweden)

    Xin-Bing Cheng

    2010-07-01

    Full Text Available The Blumlein pulse forming line (BPFL consisting of an inner coaxial pulse forming line (PFL and an outer coaxial PFL is widely used in the field of pulsed power, especially for intense electron-beam accelerators (IEBA. The output voltage waveform determines the quality and characteristics of the output beam current of the IEBA. Comparing with the conventional BPFL, an IEBA based on a helical type BPFL can increase the duration of the output voltage in the same geometrical volume. However, for the helical type BPFL, the voltage waveform on a matched load may be distorted which influences the electron-beam quality. In this paper, an IEBA based on helical type BPFL is studied theoretically. Based on telegrapher equations of the BPFL, a formula for the output voltage of IEBA is obtained when the transition section is taken into account, where the transition section is between the middle cylinder of BPFL and the load. From the theoretical analysis, it is found that the wave impedance and transit time of the transition section influence considerably the main pulse voltage waveform at the load, a step is formed in front of the main pulse, and a sharp spike is also formed at the end of the main pulse. In order to get a well-shaped square waveform at the load and to improve the electron-beam quality of such an accelerator, the wave impedance of the transition section should be equal to that of the inner PFL of helical type BPFL and the transit time of the transition section should be designed as short as possible. Experiments performed on an IEBA with the helical type BPFL show reasonable agreement with theoretical analysis.

  19. Guidelines for Distribution System Operators on Reactive Power Provision by Electric Vehicles in Low Voltage Grids

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia; Træholt, Chresten

    2017-01-01

    The increasing success of electric vehicles is bringing new technical challenges to power system operators. This work intends to provide guidelines for distribution system operators in terms of reactive power requirements when evaluating and authorizing electric vehicles supply equipment with fast...... the amount of reactive power that an individual electric vehicle is expected to provide when connected to a low voltage feeder, in order to benefit of the desired voltage rise effect in comparison to the case of unitary power factor....... charging capability in existing low voltage distribution feeders. The aim is to prevent the voltage to exceed the permitted values when charging at high power, by exploiting the effect of the reactive power. The proposed guidelines for distribution system operators are reported in a matrix, which indicates...

  20. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources.

    Science.gov (United States)

    Reale, D V; Parson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  1. Optimal power and performance trade-offs for dynamic voltage scaling in power management based wireless sensor node

    Directory of Open Access Journals (Sweden)

    Anuradha Pughat

    2016-09-01

    Full Text Available Dynamic voltage scaling contributes to a significant amount of power saving, especially in the energy constrained wireless sensor networks (WSNs. Existing dynamic voltage scaling techniques make the system slower and ignore the event miss rate. This results in degradation of the system performance when there is non-stationary workload at input. The overhead due to transition between voltage level and discrete voltage levels are also the limitations of available dynamic voltage scaling (DVS techniques at sensor node (SN. This paper proposes a workload dependent DVS based MSP430 controller model used for SN. An online gradient estimation technique has been used to optimize power and performance trade-offs. The analytical results are validated with the simulation results obtained using simulation tool “SimEvents” and compared with the available AT9OS8535 controller. Based on the stochastic workload, the controller's input voltage, operational frequency, utilization, and average wait time of events are obtained.

  2. Line-to-line voltage based modulation scheme for single-phase reduced switch ac-dc-ac converters to achieve improved performance

    DEFF Research Database (Denmark)

    Qin, Zian; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    . With the SVPWM or DPWM proposed in literatures, the generation of the references is phase voltage based. But the phase voltages actually cannot be controlled directly by the PWM converter, since they can be influenced by both of terminal voltages and the load network while the PWM converter can only control...... the former. It thus introduces complexity to the generation of the references, especially in unbalanced source or load condition. In this paper, a line-to-line voltage based PWM reference generation method is proposed. The proposed method is easy to be implemented to maximize the DC link voltage utilization...

  3. Coordinated Voltage Control of Transformer Taps on account of Hierarchical Structure in Power System

    Science.gov (United States)

    Nakachi, Yoshiki; Kato, Satoshi; Ukai, Hiroyuki

    Participation of distributed generators (DG), such as wind turbines, co-generation system etc., is natural trend from ecological point of view and will increase more and more. The outputs of these DGs mainly depend on weather condition but don't correspond to the changes of electrical load demand necessarily. On the other hand, due to the deregulation of electric power market, the power flow in power system will uncertainly vary with several power transactions. Thus, complex power flow by DGs or transactions will cause the voltage deviation. It will be difficult to sustain the voltage quality by using the conventional voltage/reactive power control in near future. In this paper, in order to avoid such a voltage deviation and to decrease the frequency of transformer tap actions, the coordinated voltage control scheme of transformer taps on account of hierarchical structure in power system is proposed. In the proposed scheme, integral of voltage deviation at each layer bus is applied to decide the timing of each transformer tap action. It is confirmed by some numerical simulations that the proposed scheme is able to respond to every conditions on voltage deviation.

  4. Electric strength of insulation on superhigh-voltage overhead transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Danis, J.; Kromer, I.L.

    1979-09-01

    Insulation for superhigh-voltage overhead transmission lines is selected on the basis of reliability during switching overvoltages and extreme changes in ambient conditions. A study of 400 kV and 750 kV insulator strings, porcelain and glass, respectively, was made to determine their performance with dusty or moist surface under these severe conditions as expected in service. Four different configurations of a double string suspended from a cross beam 30 m above ground and at various horizontal distances from lateral poles were tested. The risetime of aperiodic voltage pulses was varied from 35 ..mu..s (below critical) to 1200..mu..s (above critical) and their duration was varied from 1000 to 10,500 ..mu..s, the voltage level changed in 5% steps and successive pulses applied in 30 to 40 s intervals. The 50%-discharge voltage was estimated by the up and down method and the readings evaluated statistically by Student's method. The results yielded the voltage-time characteristics of these insulator strings, with the dip of the 50%-discharge voltage down to its minimum critical level corresponding to an overvoltage pulse with the critical risetime. Further analysis yields also the risk and the number of flashhovers, depending on the contamination distribution density, on the overvoltage amplitude distribution density, and on the number of weak spots. Contamination increases the probable number of flashovers during switching by 30 to 50%.

  5. Coordinated control for low voltage ride-through of a PMSG-based wind power plant

    Directory of Open Access Journals (Sweden)

    Khagendra Thapa

    2016-01-01

    Full Text Available Wind turbine generators should be kept connected to a power grid, while supporting the voltage recovery in the case of a grid fault to meet low voltage ride-through requirement in some grid codes. This paper proposes a coordinated control scheme that prevents the increase in the DC-link voltage by reducing the active power in the machine side converter of permanent magnet synchronous generators (PMSGs in proportion to the voltage dip at the terminal of PMSGs. The proposed scheme changes the current priorities from the active current to the reactive current to inject more reactive power for a severe fault depending on the voltage dip. In addition, the grid-side converter operates in a voltage control mode with the slope, which is the ratio of reactive current capability to the voltage tolerance around a rated value. Moreover, during the fault, the slope is changed depending on the voltage dip to inject more reactive current. The performance of the proposed scheme is validated for a wind power plant consisting of 20 units of 5-MW PMSGs using an EMTP-RV simulator. The results demonstrate that the scheme enables the PMSGs not only to survive during the fault, but also to provide a dynamic reactive power support.

  6. Model Predictive Direct Power Control for Nonredundant Fault Tolerant Grid-Connected Bidirectional Voltage Source Converter

    Directory of Open Access Journals (Sweden)

    Nan Jin

    2017-08-01

    Full Text Available This paper proposes a model predictive direct power control scheme for nonredundant fault tolerant grid-connected bidirectional voltage source converter (BVSC with balanced dc-link split capacitor voltage and high reliability. Based on the operation analysis of fault-tolerant BVSC with phase leg faults, a power predictive model of three-phase four-switch fault-tolerant topology in αβ coordinates is established, and the space voltage vectors with unbalanced dc-link split capacitor voltage are analyzed. According to the power predictive model and cost function, the optimal space voltage vector is selected to achieve a flexible, smooth transition between inverter and rectifier mode with direct power control. Pulse width modulation and phase locked loop are not required in the proposed method. The constraint of dc-link voltage constraint is designed for the cost function to achieve a central point of dc-link voltage offset suppression, which can reduce the risk of electrolytic capacitor failure for over-voltage operation. With the proposed control method, the converter can work continuously in both inverter mode and rectifier mode, even if phase leg faults occur. The simulation and experimental results show good steady-state and dynamic performance of the proposed control scheme to enhance the reliability of bidirectional power conversion.

  7. Coordinated Agent-Based Control for On-line Voltage Instability Prevention

    NARCIS (Netherlands)

    Baalbergen, J.F.

    2013-01-01

    Service interruptions have a significant impact on society and therefore the main objective of power system planning and operation is to ensure that they do not happen. Because voltage instability is one of the dynamic phenomena that may result in a system-wide blackout, this type of stability

  8. Genetic algorithm based reactive power dispatch for voltage stability improvement

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, D. [Department of Electrical and Electronics, Kalasalingam University, Krishnankoil 626 190 (India); Roselyn, J. Preetha [Department of Electrical and Electronics, SRM University, Kattankulathur 603 203, Chennai (India)

    2010-12-15

    Voltage stability assessment and control form the core function in a modern energy control centre. This paper presents an improved Genetic algorithm (GA) approach for voltage stability enhancement. The proposed technique is based on the minimization of the maximum of L-indices of load buses. Generator voltages, switchable VAR sources and transformer tap changers are used as optimization variables of this problem. The proposed approach permits the optimization variables to be represented in their natural form in the genetic population. For effective genetic processing, the crossover and mutation operators which can directly deal with the floating point numbers and integers are used. The proposed algorithm has been tested on IEEE 30-bus and IEEE 57-bus test systems and successful results have been obtained. (author)

  9. CHARACTERISTICS OF POWER SELF-COMPENSATED TRANSMISSION LINES EXTREMELY COMPACT 330-350 kV

    Directory of Open Access Journals (Sweden)

    Postolaty V.M.

    2013-12-01

    Full Text Available The optimal configuration of phases placement of double circuit compact controlled self-compensated high-voltage power lines (KUSVL with the voltage of 330-500 kV at the condition of achieving of the maximum admissible value of the electric field tension on the surface of split phase at a given design was determined. The parameters of these lines at the extreme values of the angular shift (θ between the circuits’ systems voltages were calculated. It was shown, that the surge impedance of KUSVL without special phase-shifting transformers (e.g. θ = 0˚ is minimal, and is equal (for each phase for the option of 330 kV and wires 3AS-300/39 - 196 ohms, and for voltage of 500 kV and phase conductors 6AS-240/39 –162 ohms. The magnitude of transmission capacity of considered line (for both circuits at rated voltage is maximal and equal to 1118 MW (for 330 kV line and 3080 MW (for 500 kV line. At changing of line to the mode of angle θ = 180˚ (with special phase-shifting transformer surge impedance is maximal and the transmission capacity minimal. Ratio of the maximal value of transmission capacity to the minimal (regulation range reaches values of up to 1.5.

  10. Use of DFIWG for Improvement of Voltage Stability Condition of a Power System

    Science.gov (United States)

    Hazarika, Durlav; Das, Ranjay

    2017-12-01

    This paper describes a method for improvement of voltage stability condition of a multi-bus power system by regulating reactive power generation at a Doubly Fed Induction Wind Generator (DFIWG). For this purpose, sensitivity relation between changes in voltage stability index at a bus with respect to change in reactive power generation of the DFIWG is derived. This relation is used to determine the required amount of change in rotor current of the DFIWG to improve the voltage stability index of the bus.

  11. Impact on Generator Reactive Power Limits on a Static Voltage Stability

    Directory of Open Access Journals (Sweden)

    TOVAR-GONZALEZ, E. A.

    2011-11-01

    Full Text Available Voltage stability margin in a power system is closely related with the availability of reactive power in the system. Therefore, adequate modeling of the reactive power sources becomes an important issue in this type of studies. The Minimum Singular Value of the load flow Jacobian matrix has been commonly used as a static voltage stability index. In this paper, such index is used to assess the influence on the static voltage stability limit of modeling the generators reactive power limits by its capability curve. Simulation results on a test system indicate that modeling the reactive power limits of the generating units by the simplified Qmin/Qmax approach, commonly used by most of the load flow programs, yields optimistic values for this voltage stability index.

  12. Voltage Control of Distribution Grids with Multi-Microgrids Using Reactive Power Management

    Directory of Open Access Journals (Sweden)

    WLODARCZYK, P.

    2015-02-01

    Full Text Available Low-voltage Microgrids can be valuable sources of ancillary services for the Distribution System Operators (DSOs. The aim of this paper was to study if and how multi-microgrids can contribute to Voltage Control (VC in medium-voltage distribution grids by means of reactive power generation and/or absorption. The hierarchical control strategy was proposed with the main focus on the tertiary control which was defined as optimal power flow problem. The interior-point algorithm was applied to optimise experimental benchmark grid with the presence of Distributed Energy Resources (DERs. Moreover, two primary objectives were formulated: active power losses and amount of reactive power used to reach the voltage profile. As a result the active power losses were minimised to the high extent achieving the savings around 22% during entire day.

  13. Spatial and temporal instabilities in high voltage power devices

    Energy Technology Data Exchange (ETDEWEB)

    Milady, Saeed

    2010-01-29

    Dynamic avalanche can occur during the turn-off process of high voltage bipolar devices, e.g. IGBTs and p{sup +}n{sup -}n{sup +} power diodes, that may result in spatial instabilities of the homogeneous current density distribution across the device and the formation of current filaments. Filaments may cause the destruction of the device, mainly because of the high local temperatures. The first part of this work is dedicated to the current filament behavior. The positive feedback mechanisms caused by the transient current flow through the gate capacitance of an IGBT operating under short circuit conditions may result in oscillations and temporal instabilities of the IGBT current. The oscillations may cause electromagnetic interference (EMI). Furthermore, the positive feedback mechanism may accelerate the over-heating of the device and result in a thermal run-away. This is the subject of the second part of this work. In the first part of this work using the device simulation results of power diodes the underlying physical mechanisms of the filament dynamic is investigated. Simulation results of diode structures with evenly distributed doping inhomogeneities show that, the filament motion gets smoother as the distance between the inhomogeneities decreases. Hopping to faraway inhomogeneities turns into the hopping to neighboring ones and finally a smooth motion. In homogeneous structures the slow inhibitory effect of the electron-hole plasma extraction and the fast activation, due to hole current flowing along the filament, result in a smooth filament motion. An analytical model for the filament velocity under isothermal conditions is presented that can reproduce the simulation data satisfactorily. The influence of the boundary conditions on the filament behavior is discussed. The positive beveled edge termination prohibits a long stay of the filament at the edge reducing the risk of filament pinning. Self-heating effects may turn the initially electrically triggered

  14. PSO-Based Voltage Control Strategy for Loadability Enhancement in Smart Power Grids

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2016-12-01

    Full Text Available This paper proposes a new voltage control methodology using the particle swarm optimization (PSO technique for smart grid loadability enhancement. The goal of this paper is to achieve reliable and efficient voltage profile/stability regulation in power grids. This methodology is based on the decouple power flow equations and the worst-case design technique. Specifically, the secondary voltage control (SVC problem is formulated as an L-infinity norm minimization problem which considers overall load voltage deviations in electrical power systems as an objective model, and the PSO technique is employed to determine a robust control action which aims to improve voltage profile and to enlarge transmission grid loadability by optimal coordinated control of VAR sources. The methodology was successfully tested on several IEEE benchmark systems.

  15. Modelling, stability and control of voltage behaviour in power supply systems

    Energy Technology Data Exchange (ETDEWEB)

    Hill, David J. [Sydney Univ., NSW (Australia). Dept. of Electrical Engineering; Hisken, Ian A. [Newcastle Univ., NSW (Australia). Dept. of Electrical and Computer Engineering

    1994-12-31

    This paper gives an overview of a line of work on mid to long term voltages stability analysis and control in power systems. The results are based on use of a novel approach to dynamic load modelling using aggregate nonlinear structures. In general, the model for the transmission network and supply end dynamics is of the hybrid differential - algebraic - discrete kind. Various stability questions are precisely formulated and analysed in terms of network and load characteristics (steady-state and transient). The results are shown to be a useful framework for deriving criteria of the where, when and how much kind for various control actions such as load Thedding and tap-blocking. (author) 47 refs., 15 figs., 1 tab.

  16. Advanced power electronics converters PWM converters processing AC voltages

    CERN Document Server

    dos Santos, Euzeli

    2014-01-01

    This book covers power electronics, in depth, by presenting the basic principles and application details, which can be used both as a textbook and reference book.  Introduces a new method to present power electronics converters called Power Blocks Geometry. Applicable for courses focusing on power electronics, power electronics converters, and advanced power converters. Offers a comprehensive set of simulation results to help understand the circuits presented throughout the book

  17. Static voltage stability analysis of power systems considering induction motor components of loads

    Energy Technology Data Exchange (ETDEWEB)

    Radman, G.; Pama, A. [Tennessee Technological Univ., Cookeville, TN (United States). Dept. of Electrical and Computer Engineering; Inst. of Electrical and Electronics Engineers, New York, NY (United States)

    2007-07-01

    Power systems are typically loaded to the point of voltage collapse in order to test system voltage stability limits. Voltage profiles of the system are determined by characterizing PV-curves plotted using continuation power flow programs. In this study, voltage stability analyses were performed using a continuation power flow program designed to accommodate the induction motor components of loads. An equivalent induction machine model with aggregate parameters was used for each bus in order to accommodate for the induction motor component of each load. A modified version of the Newton-Raphson method of power flow solutions was used to accommodate the loads. A case study of the New England 39-bus power system was used to demonstrate the method as well as to compare it with traditional methods of obtaining voltage stability limits. It was concluded that the consideration of induction motor components during analyses reduced the overall voltage stability limit and overall voltage profile of the system. Power flow equations were included. 18 refs., 1 tab., 5 figs.

  18. Challenge of Primary Voltage Control in Large Scale Wind Integrated Power System: A Danish Power System Case Study

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Chen, Zhe; Thøgersen, Paul

    2013-01-01

    Grid integration of Renewable Energy (RE) at large scale poses vast majority of challenges to secure and stable operation of Power System. This paper presents the challenge of short circuit power and primary voltage control of wind integrated power system where majority of conventional generators...... of operational and future model of western Danish power system has been presented to support the effectiveness of demonstrated alternatives....... are replaced by wind generators. The impact of large scale wind integration on fast reactive power support is studied in this paper. Considering both technical and economic aspects, alternatives to address the challenge of dynamic voltage support have also been demonstrated in this paper. A case study...

  19. Power System Stability Using Decentralized Under Frequency and Voltage Load Shedding

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Silva, Filipe Faria Da; Bak, Claus Leth

    2014-01-01

    information to shed the loads with higher voltage decay first. Therefore, this approach deals with coordination of voltage and frequency information instead of independent methods. Numerical simulations which are carried out in DigSilent PowerFactory software confirm the efficiency of proposed methodology...

  20. Reactive Power Sharing and Voltage Harmonic Distortion Compensation of Droop Controlled Single Phase Islanded Microgrids

    DEFF Research Database (Denmark)

    Micallef, Alexander; Apap, Maurice; Spiteri-Staines, Cyril

    2014-01-01

    and reduction of the voltage harmonic distortion at the point of common coupling (PCC). Experimental results were then presented to show the suitability of the proposed algorithms in achieving reactive power sharing and in improving the voltage harmonic distortion at the PCC....

  1. Comparison of two voltage control strategies for a wind power plant

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Philip C.; Rodriguez, Pedro

    2011-01-01

    plants. This paper addresses the analysis of two different voltage control strategies for a wind power plant, i.e. decentralized and centralized voltage control schemes. The analysis has been performed using the equivalent and simplified transfer functions of the system. Using this representation...

  2. Computation of Steady State Nodal Voltages for Fast Security Assessment in Power Systems

    DEFF Research Database (Denmark)

    Møller, Jakob Glarbo; Jóhannsson, Hjörtur; Østergaard, Jacob

    2014-01-01

    Development of a method for real-time assess-ment of post-contingency nodal voltages is introduced. Linear network theory is applied in an algorithm that utilizes Thevenin equivalent representation of power systems as seen from every voltage-controlled node in a network. The method is evaluated...

  3. High performance AC–DC control power supply for low voltage ride ...

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana; Volume 41; Issue 2 ... The CPS design presented here maintains a constant 24Vdc output even over a wide (90Vrms to 270Vrms ) ac voltage variation at its input for a High Power Converter (HPC). ... The CPS was tested for wide input voltage range (vin) and the performance validates the design.

  4. Nonlinear Parasitic Capacitance Modelling of High Voltage Power MOSFETs in Partial SOI Process

    DEFF Research Database (Denmark)

    Fan, Lin; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    : off-state, sub-threshold region, and on-state in the linear region. A high voltage power MOSFET is designed in a partial Silicon on Insulator (SOI) process, with the bulk as a separate terminal. 3D plots and contour plots of the capacitances versus bias voltages for the transistor summarize...

  5. Geotechnical assessments of upgrading power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Andrew [Coffey Geotechnics Ltd., Harrogate (United Kingdom)

    2012-11-01

    One of the consequences of increasing demand for energy is a corresponding requirement for increased energy distribution. This trend is likely to be magnified by the current tendency to generate power in locations remote from centres of population. New power transmission routes are expensive and awkward to develop, and there are therefore benefits to be gained by upgrading existing routes. However, this in turn raises problems of a different nature. The re-use of any structure must necessarily imply the acceptance of unknowns. The upgrading of transmission lines is no exception to this, particularly when assessing foundations, which in their nature are not visible. A risk-based approach is therefore used. This paper describes some of the geotechnical aspects of the assessment of electric power transmission lines for upgrading. It briefly describes the background, then discusses some of the problems encountered and the methods used to address them. These methods are based mainly on information obtained from desk studies and walkover surveys, with a limited amount of intrusive investigation. (orig.)

  6. Simulation study on transient electric shock characteristics of human body under high voltage ac transmission lines

    Science.gov (United States)

    Huang, Tao; Zou, Yanhui; Lv, Jianhong; Yang, Jinchun; Tao, Li; Zhou, Jianfei

    2017-09-01

    Human body under high-voltage AC transmission lines will produce a certain induced voltage due to the electrostatic induction. When the human body contacts with some grounded objects, the charges transfer from the body to the ground and produce contact current which may cause transient electric shock. Using CDEGS and ATP/EMTP, the paper proposes a method for quantitatively calculating the transient electric shock characteristics. It calculates the human body voltage, discharge current and discharge energy under certain 500kV compact-type transmission lines and predicts the corresponding human feelings. The results show that the average root value of discharge current is less than 10mA when the human body is under the 500kV compact-type transmission lines and the human body is overall safe if the transmission lines satisfy the relevant design specifications. It concludes that the electric field strength above the ground should be limited to 4kV/m through the residential area for the purpose of reducing the electromagnetic impact.

  7. Conducted Transients on Spacecraft Primary Power Lines

    Science.gov (United States)

    Mc Closkey, John; Dimov, Jen

    2017-01-01

    One of the sources of potential interference on spacecraft primary power lines is that of conducted transients resulting from equipment being switched on and off of the bus. Susceptibility to such transients is addressed by some version of the CS06 requirement of MIL-STD-461462. This presentation provides a summary of the history of the CS06 requirement and test method, a basis for understanding of the sources of these transients, analysis techniques for determining their worst-case characteristics, and guidelines for minimizing their magnitudes and applying the requirement appropriately.

  8. Acoustic power balance in lined ducts

    Science.gov (United States)

    Eversman, W.

    1979-01-01

    It is shown that the two common definitions of acoustic energy density and intensity in uniform unlined ducts carrying uniform flow are compatible to the extent that both energy densities can be used in an appropriate variational principle to derive the convected wave equation. When the duct walls are lined both energy densities must be modified to account for the wall energy density. This results in a new energy conservation equation which utilizes a modified definition of axial power and accounts for wall dissipation. Computations in specific cases demonstrate the validity of the modified acoustic energy relation.

  9. PMU-Aided Voltage Security Assessment for a Wind Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Huaiguang; Zhang, Yingchen; Zhang, Jun Jason; Muljadi, Eduard

    2015-10-05

    Because wind power penetration levels in electric power systems are continuously increasing, voltage stability is a critical issue for maintaining power system security and operation. The traditional methods to analyze voltage stability can be classified into two categories: dynamic and steady-state. Dynamic analysis relies on time-domain simulations of faults at different locations; however, this method needs to exhaust faults at all locations to find the security region for voltage at a single bus. With the widely located phasor measurement units (PMUs), the Thevenin equivalent matrix can be calculated by the voltage and current information collected by the PMUs. This paper proposes a method based on a Thevenin equivalent matrix to identify system locations that will have the greatest impact on the voltage at the wind power plant's point of interconnection. The number of dynamic voltage stability analysis runs is greatly reduced by using the proposed method. The numerical results demonstrate the feasibility, effectiveness, and robustness of the proposed approach for voltage security assessment for a wind power plant.

  10. PMU-Aided Voltage Security Assessment for a Wind Power Plant: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, H.; Zhang, Y. C.; Zhang, J. J.; Muljadi, E.

    2015-04-08

    Because wind power penetration levels in electric power systems are continuously increasing, voltage stability is a critical issue for maintaining power system security and operation. The traditional methods to analyze voltage stability can be classified into two categories: dynamic and steady-state. Dynamic analysis relies on time-domain simulations of faults at different locations; however, this method needs to exhaust faults at all locations to find the security region for voltage at a single bus. With the widely located phasor measurement units (PMUs), the Thevenin equivalent matrix can be calculated by the voltage and current information collected by the PMUs. This paper proposes a method based on a Thevenin equivalent matrix to identify system locations that will have the greatest impact on the voltage at the wind power plant’s point of interconnection. The number of dynamic voltage stability analysis runs is greatly reduced by using the proposed method. The numerical results demonstrate the feasibility, effectiveness, and robustness of the proposed approach for voltage security assessment for a wind power plant.

  11. Common-mode Voltage Reduction in a Motor Drive System with a Power Factor Correction

    DEFF Research Database (Denmark)

    Adabi, J.; Boora, A.A.; Zare, F.

    2012-01-01

    to reduce shaft voltage in a three-phase AC motor drive system. In this topology, the AC-DC diode rectifier influences the common-mode voltage generated by the inverter because the placement of the neutral point is changing in different rectifier circuit states. A pulse width modulation technique......Common-mode voltage generated by a power converter in combination with parasitic capacitive couplings is a potential source of shaft voltage in an AC motor drive system. In this study, a three-phase motor drive system supplied with a single-phase AC-DC diode rectifier is investigated in order...

  12. Voltage and frequency control of wind-powered islanded microgrids based on induction generator and STATCOM

    DEFF Research Database (Denmark)

    Bouzid, Allal; Sicard, Pierre; Guerrero, Josep M.

    2015-01-01

    This paper presents a comprehensive modeling of a three-phase cage induction machine used as a self-excited squirrel-cage induction generator (SEIG), and discusses the regulation of the voltage and frequency of a self-excited SEIG based on the action of the static synchronous Compensator (STATCOM......). The STATCOM with the proposed controller consists of a three-phase voltage-sourced inverter and a DC voltage. The compensator can provide the active and reactive powers and regulate AC system bus voltage and the frequency, but also may enhance the load stability. Moreover, a feed forward control method...

  13. Resonant voltage surges in power transmission systems; Sobretensiones resonantes en sistemas de transmision

    Energy Technology Data Exchange (ETDEWEB)

    Fuentes Rosado, Jesus

    1988-07-01

    The electric power transmission systems are frequently designed with several transmission lines on the same tower or in the right of way; all this justified mainly for economic or environmental reasons. The transmission power lines generally acquire substantial lengths, of several hundreds of kilometers. The capacitive effect of the transmission power lines, particularly when they are long and are with low power flow, causes high voltages and it is necessary to install reactors in derivation to be able to control the voltages within reasonable values ({+-} 5% of its nominal value). The risk exists, nevertheless, that the electrical circuit formed by the power lines and reactors presents resonance. In case of existing resonance between the capacitive effect of the power line and the inductive effect of the reactor, abnormally high voltages or current circulation of zero sequence appear that could cause damages to reactors, lightning arresters and circuit breakers; multiple reports exist on this type of incidents. It is then necessary, that the planners of electrical power systems prevent the capacity and the characteristics of the reactors for each particular application. In this thesis the equations that allow to determine the values of the reactors capacity for which there would be resonance, are developed. Results for three forms of modeling the transmission power lines are presented and compared: (i) By means of distributed parameters, (ii) By means of concentrated parameters and (iii) Considering solely the capacitive effect of the power lines, denominated electrostatic method. The differences for the problem under study between transposed and not transposed lines are discussed in detail. Also the effect of the different types of reactors; core and armor, single-phase as well as three-phase is discussed, in a similar form, the transformers are studied. The analytical developments are integrated in a digital computer program that allows to analyze the different

  14. Coordinated Voltage Control in Offshore HVDC Connected Cluster of Wind Power Plants

    DEFF Research Database (Denmark)

    Sakamuri, Jayachandra N.; Rather, Zakir Hussain; Rimez, Johan

    2016-01-01

    This paper presents a coordinated voltage control scheme (CVCS) for a cluster of offshore wind power plants (OWPPs) connected to a VSC HVDC system. The primary control point of the proposed voltage control scheme is the introduced Pilot bus, which is having the highest short circuit capacity...... in the offshore AC grid. The developed CVCS comprehends an optimization algorithm, aiming for minimum active power losses in the offshore grid, to generate voltage reference to the Pilot bus. During steady state operation, the Pilot bus voltage is controlled by dispatching reactive power references to each wind...... turbine (WT) in the WPP cluster based on their available reactive power margin and network sensitivity based participation factors, which are derived from the dV/dQ sensitivity of a WT bus w.r.t the Pilot bus. This method leads to minimization of the risk of undesired effects, particularly overvoltage...

  15. Voltage Stability Impact of Grid-Tied Photovoltaic Systems Utilizing Dynamic Reactive Power Control

    Science.gov (United States)

    Omole, Adedamola

    Photovoltaic (PV) DGs can be optimized to provide reactive power support to the grid, although this feature is currently rarely utilized as most DG systems are designed to operate with unity power factor and supply real power only to the grid. In this work, the voltage stability of a power system embedded with PV DG is examined in the context of the high reactive power requirement after a voltage sag or fault. A real-time dynamic multi-function power controller that enables renewable source PV DGs to provide the reactive power support necessary to maintain the voltage stability of the microgrid, and consequently, the wider power system is proposed. The loadability limit necessary to maintain the voltage stability of an interconnected microgrid is determined by using bifurcation analysis to test for the singularity of the network Jacobian and load differential equations with and without the contribution of the DG. The maximum and minimum real and reactive power support permissible from the DG is obtained from the loadability limit and used as the limiting factors in controlling the real and reactive power contribution from the PV source. The designed controller regulates the voltage output based on instantaneous power theory at the point-of-common coupling (PCC) while the reactive power supply is controlled by means of the power factor and reactive current droop method. The control method is implemented in a modified IEEE 13-bus test feeder system using PSCADRTM power system analysis software and is applied to the model of a Tampa ElectricRTM PV installation at Lowry Park Zoo in Tampa, FL. This dissertation accomplishes the systematic analysis of the voltage impact of a PV DG-embedded power distribution system. The method employed in this work bases the contribution of the PV resource on the voltage stability margins of the microgrid rather than the commonly used loss-of-load probability (LOLP) and effective load-carrying capability (ELCC) measures. The results of

  16. Experimental research on mechanical properties of high voltage transmission lines after the simulated wildfires

    Directory of Open Access Journals (Sweden)

    Wang Tianzheng

    2015-01-01

    Full Text Available In order to determine whether the mechanical performance after the fires of high voltage transmission lines meets the requirements of normal use, this article simulates the wildfire, and does the mechanical performance experiment of high voltage transmission lines(HVT lines after the simulated wildfires. The experiment studied the breaking force and elongation of each layer of 500kv HVT lines after the simulated wildfire. Experimental results show that, after fires, each layer of single aluminum wires of 500kv HVT lines have low breaking force which can be decreased obviously to half of that of new lines. For the steel core, decrease of breaking force is not obvious than aluminum wires, and with the increasing degree of wildfires, it increases gradually to a maximum of 35% of new steel lines’ breaking force. After wildfires, aluminum lines’ resistance ability of deformation decreases significantly, and its plastic deformation increases obviously during uniaxial tension. The steel core has little plastic deformation, and layers of aluminum become fluffy after fires. Therefore, the steel core main bearing load after wildfires.

  17. Multi-Stage Optimization-Based Automatic Voltage Control Systems Considering Wind Power Forecasting Errors

    DEFF Research Database (Denmark)

    Qin, Nan; Bak, Claus Leth; Abildgaard, Hans

    2017-01-01

    cost and the generator reactive power output cost. The problem is formulated in a multi-stage optimal reactive power flow (MORPF) framework, solved by the nonlinear programming techniques via a rolling process. The voltage uncertainty caused by wind power forecasting errors is considered in the optimal...

  18. Voltage ripple compensation for grid connected electrolyser power supply using small DC link capacitor

    DEFF Research Database (Denmark)

    Török, Lajos; Mathe, Laszlo; Munk-Nielsen, Stig

    2014-01-01

    The purpose of this work was to investigate a three-phase-grid connected power supply using small DC link capacitor for electrolyser application. The hydrogen generation system requires low voltage and high current power supply. Thus the structure of the 3-phase power supply is defined as follows...

  19. Design of a pulsewidth-modulated resonant converter for a high-output-voltage power supply

    Science.gov (United States)

    Turnbull, Fred G.; Tompkins, Russell E.

    1987-12-01

    The design and fabrication of a parallel resonant converter circuit and a high-frequency step-up transformer used to supply an adjustable dc voltage to a load is described. The 500-W system is operated from 115/230 V single-phase 60Hz power, which is rectified and filtered to form a 310-V dc link. A two-transistor half-bridge circuit operating at a fixed frequency above the ciruits resonant frequency converts the dc voltage to an ac voltage at approximately 20 kHx. This high-frequency voltage is transformed with a low-capacitance oil-impregnated ferrite transformer. The output voltage is rectified to form a dc voltage with a maximum value of 90-kV peak. The output voltage is adjustable using pulsewidth modulation of the conduction time of the two transistors in the power circuit. The energy stored in the resonant circuit provides a sinusoidal transformer voltage at fixed frequency over a wide range of control. The system is provided with a closed-loop peak-voltage regulator and an on-off capability from the control electronics. The transformer is designed for a specific value of inductance and capacitance to operate at the desired resonant frequency and characteristic impedance.

  20. A new application area for fullerenes: voltage stabilizers for power cable insulation.

    Science.gov (United States)

    Jarvid, Markus; Johansson, Anette; Kroon, Renee; Bjuggren, Jonas M; Wutzel, Harald; Englund, Villgot; Gubanski, Stanislaw; Andersson, Mats R; Müller, Christian

    2015-02-04

    Fullerenes are shown to be efficient voltage-stabilizers for polyethylene, i.e., additives that increase the dielectric strength of the insulation material. Such compounds are highly sought-after because their use in power-cable insulation may considerably enhance the transmission efficiency of tomorrow's power grids. On a molal basis, fullerenes are the most efficient voltage stabilizers reported to date. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. An Efficient Approach for Fast and Accurate Voltage Stability Margin Computation in Large Power Grids

    OpenAIRE

    Heng-Yi Su

    2016-01-01

    This paper proposes an efficient approach for the computation of voltage stability margin (VSM) in a large-scale power grid. The objective is to accurately and rapidly determine the load power margin which corresponds to voltage collapse phenomena. The proposed approach is based on the impedance match-based technique and the model-based technique. It combines the Thevenin equivalent (TE) network method with cubic spline extrapolation technique and the continuation technique to achieve fast an...

  2. Improved Direct Power Control for Grid-Connected Voltage Source Converters

    DEFF Research Database (Denmark)

    Gui, Yonghao; Kim, Chunghun; Chung, Chung Choo

    2018-01-01

    A novel grid voltage modulated direct power control (GVM-DPC) strategy for a grid-connected voltage source converter is proposed to control the instantaneous active and reactive powers directly. The GVM-DPC method consists of a nonlinear GVM controller, a conventional controller (feedforward and PI...... and robustness of the proposed control architecture. In addition, the total harmonic distortion of the current is 1.9% which is much less than the requirement for grid operation....

  3. Design and implementation of high performance direct power control of three-phase PWM rectifier, via fuzzy and PI controller for output voltage regulation

    Energy Technology Data Exchange (ETDEWEB)

    Bouafia, Abdelouahab; Krim, Fateh [Laboratoire d' Electronique de Puissance et Commande Industrielle (LEPCI), Universite de Setif, Departement d' electronique, Route de Bejaia, Setif (Algeria); Gaubert, Jean-Paul [Laboratoire d' Automatique et d' Informatique Industrielle (LAII), ESIP, Universite de Poitiers (France)

    2009-01-15

    This paper proposes direct power control (DPC) for three-phase PWM rectifiers using a new switching table, without line voltage sensors. The instantaneous active and reactive powers, directly controlled by selecting the optimum state of the converter, are used as the PWM control variables instead of the phase line currents being used. The main goal of the control system is to maintain the dc-bus voltage at the required level, while input currents drawn from the power supply should be sinusoidal and in phase with respective phase voltages to satisfy the unity power factor (UPF) operation. Conventional PI and a designed fuzzy logic-based controller, in the dc-bus voltage control loop, have been used to provide active power command. A dSPACE based experimental system was developed to verify the validity of the proposed DPC. The steady-state, and dynamic results illustrating the operation and performance of the proposed control scheme are presented. As a result, it was confirmed that the novel DPC is much better than the classical one. Line currents very close to sinusoidal waveforms (THD < 2%) and good regulation of dc-bus voltage are achieved using PI or fuzzy controller. Moreover, fuzzy logic controller gives excellent performance in transient state, a good rejection of impact load disturbance, and a good robustness. (author)

  4. Voltage Source Inverter/Converter for the Improvement of Power Quality Using Fuzzy Logic Controller

    OpenAIRE

    T Jagan Mohan Rao; P Anil Kumar

    2014-01-01

    In recent years, the applications of power electronics have grown tremendously. These power electronic systems offer highly nonlinear characteristics. To overcome those non linearities active power filters are preferred. This paper presents and compares the performance of two controllers namely Fuzzy Logic and Proportional Integral (PI) applied to a voltage source inverter / converter which operates as an active power filter. The active power filter is operated to compensate h...

  5. An improved direct feedback linearization technique for transient stability enhancement and voltage regulation of power generators

    Energy Technology Data Exchange (ETDEWEB)

    Kenne, Godpromesse [Laboratoire d' Automatique et d' Informatique Appliquee (LAIA), Departement de Genie Electrique, Universite de Dschang, B.P. 134 Bandjoun, Cameroun; Goma, Raphael; Lamnabhi-Lagarrigue, Francoise [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Nkwawo, Homere [Departement GEII, Universite Paris XIII, IUT Villetaneuse, 99 Avenue Jean Baptiste Clement, 93430 Villetaneuse (France); Arzande, Amir; Vannier, Jean Claude [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France)

    2010-09-15

    In this paper, a simple improved direct feedback linearization design method for transient stability and voltage regulation of power systems is discussed. Starting with the classical direct feedback linearization technique currently applied to power systems, an adaptive nonlinear excitation control of synchronous generators is proposed, which is new and effective for engineering. The power angle and mechanical power input are not assumed to be available. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of angular speed, active electric power and generator terminal voltage. Experimental results of a practical power system show that fast response, robustness, damping, steady-state and transient stability as well as voltage regulation are all achieved satisfactorily. (author)

  6. The interaction of spacecraft high voltage power systems with the space plasma environment

    Science.gov (United States)

    Domitz, S.; Grier, N. T.

    1974-01-01

    Research work has shown that the interaction of a spacecraft and its high voltage power systems with the space plasma environment can result in harmful power loss and damage to insulators and metal surfaces. Insulator and solar panel tests were performed and flight tests are planned. High voltage power processing equipment was shown to be affected by power loss, and by transients due to plasma interactions. Power loss was determined to be roughly proportional to the square of the voltage and increases approximately as the square root of the area. Kapton, Teflon, and glass were found to be satisfactory insulating materials and it is concluded that for large space power stations should consider the effect of large pinhole currents.

  7. Optimization of Normal Regimes of Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    E. G. Pospelov

    2006-01-01

    Full Text Available In order to optimize normal regimes of the power transmission lines notions of economic, maximum and the largest efficiency of a transmission line are used. Power losses by wire corona transmission losses are considered.

  8. System for Relay Protection Command Transmission by High-Voltage Lines

    Directory of Open Access Journals (Sweden)

    D. A. Yenkov

    2009-01-01

    Full Text Available Development of a system for relay protection command transmission by high-voltage lines is shown in the paper. The paper describes an architecture of the system, main principles of its operation, engineering aspects of the development that is accomplishment of technical requirements, solution of trades-off. Justification of the selected design and an algorithm of the reliable detection of relay protection signals are given in the paper.

  9. Investigating Enhancement Mode Gallium Nitride Power FETs in High Voltage, High Frequency Soft Switching Converters

    DEFF Research Database (Denmark)

    Nour, Yasser; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    of using enhancement mode gallium nitride switches to form a 50V quasi-square-wave zero-voltage-switching buck converter running at 2-6 MHz under full load. The designed converter achieved 83% efficiency converting 50V input voltage to 12.2V at 9W load.......An increased attention has been detected to develop smaller and lighter high voltage power converters in the range of 50V to 400V domain. The main applications for these converters are mainly focused for Power over Ethernet (PoE), LED lighting and AC adapters. This work will discuss a study...

  10. Investigating Enhancement Mode Gallium Nitride Power FETs in High Voltage, High Frequency Soft Switching Converters

    DEFF Research Database (Denmark)

    Nour, Yasser; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2016-01-01

    An increased attention has been detected to develop smaller and lighter high voltage power converters in the range of 50V to 400V domain. The main applications for these converters are mainly focused for Power over Ethernet (PoE), LED lighting and AC adapters. This work will discuss a study of us...... of using enhancement mode gallium nitride switches to form a 50V quasi-square-wave zero-voltage-switching buck converter running at 2-6 MHz under full load. The designed converter achieved 83% efficiency converting 50V input voltage to 12.2V at 9W load....

  11. Analysis and Experimental Evaluation of Power Line Transmission Parameters for Power Line Communication

    Science.gov (United States)

    Mlynek, P.; Misurec, J.; Koutny, M.; Fujdiak, R.; Jedlicka, T.

    2015-04-01

    The article describes a way of evaluating the power line channel frequency response and input impedance by means of the linear time-invariant (LTI) power line generator. Two possible methods are introduced for the calculation of primary parameters: the first method depends on the physical realization and physical dimension of the cable, and the second method is derived from the data provided by typical electrical cable manufacturers. Based on these methods, a comparison of transfer functions was made. This is followed by measurement evaluation and numerical verification on a simple topology

  12. Apparatus and Method for Communication over Power Lines

    Science.gov (United States)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, III, Lawrence C. (Inventor); Nappier, Jennifer M. (Inventor)

    2017-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  13. Artificial Neural Network Application for Power Transfer Capability and Voltage Calculations in Multi-Area Power System

    Directory of Open Access Journals (Sweden)

    Palukuru NAGENDRA

    2010-12-01

    Full Text Available In this study, the use of artificial neural network (ANN based model, multi-layer perceptron (MLP network, to compute the transfer capabilities in a multi-area power system was explored. The input for the ANN is load status and the outputs are the transfer capability among the system areas, voltage magnitudes and voltage angles at concerned buses of the areas under consideration. The repeated power flow (RPF method is used in this paper for calculating the power transfer capability, voltage magnitudes and voltage angles necessary for the generation of input-output patterns for training the proposed MLP neural network. Preliminary investigations on a three area 30-bus system reveal that the proposed model is computationally faster than the conventional method.

  14. Numerical Model with Arc Length Variation of Welding Arc with Constant Voltage Power Source

    OpenAIRE

    Tanaka, Manabu; Tsujimura, Yoshihiro; Tashiro, Shinichi

    2012-01-01

    In the present paper, Tungsten Inert Gas (TIG) arc with Constant Voltage (CV) power source is modeled if arc length changes. And TIG arc with Constant Current (CC) power source is also modeled if arc length changes. The TIG arc is assumed on base material of water-cooled copper. For the CV power source, Maximum temperature of arc plasma and arc current increase with decrease of arc length. For the CC power source, arc voltage changes but maximum temperatures of arc plasma is almost constant i...

  15. Gyrotron Output Power Stabilization by PID Feedback Control of Heater Current and Anode Voltage

    Science.gov (United States)

    Khutoryan, E. M.; Idehara, T.; Kuleshov, A. N.; Ueda, K.

    2014-12-01

    To provide stable output power of a gyrotron during long operation time the power stabilization was achieved by two schemes with PID feedback control of heater current and anode voltage. It was based on the dependence of the output power on both the anode voltage and the beam current and also on the dependence of the beam current on the gun heater current. Both schemes provided decrease of the power standard deviation to 0.3-0.5%. The comparison between parameters of both schemes is discussed in the paper.

  16. A Low-Power and Low-Voltage Power Management Strategy for On-Chip Micro Solar Cells

    Directory of Open Access Journals (Sweden)

    Ismail Cevik

    2015-01-01

    Full Text Available Fundamental characteristics of on-chip micro solar cell (MSC structures were investigated in this study. Several MSC structures using different layers in three different CMOS processes were designed and fabricated. Effects of PN junction structure and process technology on solar cell performance were measured. Parameters for low-power and low-voltage implementation of power management strategy and boost converter based circuits utilizing fractional voltage maximum power point tracking (FVMPPT algorithm were determined. The FVMPPT algorithm works based on the fraction between the maximum power point operation voltage and the open circuit voltage of the solar cell structure. This ratio is typically between 0.72 and 0.78 for commercially available poly crystalline silicon solar cells that produce several watts of power under typical daylight illumination. Measurements showed that the fractional voltage ratio is much higher and fairly constant between 0.82 and 0.85 for on-chip mono crystalline silicon micro solar cell structures that produce micro watts of power. Mono crystalline silicon solar cell structures were observed to result in better power fill factor (PFF that is higher than 74% indicating a higher energy harvesting efficiency.

  17. High Voltage Power Converter for Large Wind Turbine

    DEFF Research Database (Denmark)

    Sztykiel, Michal

    system operates at 20 kV level - identical as for the collector distribution network. Medium voltage operation allows the converter unit along with the filter to be installed on the base platform inside the tower. In this manner, more space in the nacelle can be flexibly accommodated by the mechanical...... application. System B consists of the generator-side 2-level converter, DC/DC boost unit and a grid-side NPC-3L converter. System C is made of a seriesconnected full-bridge cells on the generator-side, and a grid-side NPC-5L converter. The performance of the proposed topologies is analyzed both under...

  18. A Low-input-voltage Wireless Power Transfer for Biomedical Implants

    DEFF Research Database (Denmark)

    Jiang, Hao; Bai, Kangjun; Zhu, Weijie

    2015-01-01

    Wireless power transfer is an essential technology to increase implants' longevity. A pair of inductivelycoupled coils operating at radio-frequency is extensively used to deliver electrical power to implants wirelessly. In this system, a power conditioning circuit is required convert the induced...... in the rectifier for the efficient AC to DC conversion. This requirement results in larger coil size, shorter operating distance or more stringent geometrical alignment between the two coils. In this paper, a low-input-voltage wireless power transfer has been demonstrated. In this system, the opencircuit voltage...... of the induced 5 kHz AC input is as low as ~ 190 mV, and it has been converted to 5 V DC over a 25 kΩ resistor. Both the output voltage and the power drawn into the receiving coil can be regulated by the duty cycle of a control signal. The described system has the potential to reduce the size of the receiving...

  19. Bionic Vision-Based Intelligent Power Line Inspection System.

    Science.gov (United States)

    Li, Qingwu; Ma, Yunpeng; He, Feijia; Xi, Shuya; Xu, Jinxin

    2017-01-01

    Detecting the threats of the external obstacles to the power lines can ensure the stability of the power system. Inspired by the attention mechanism and binocular vision of human visual system, an intelligent power line inspection system is presented in this paper. Human visual attention mechanism in this intelligent inspection system is used to detect and track power lines in image sequences according to the shape information of power lines, and the binocular visual model is used to calculate the 3D coordinate information of obstacles and power lines. In order to improve the real time and accuracy of the system, we propose a new matching strategy based on the traditional SURF algorithm. The experimental results show that the system is able to accurately locate the position of the obstacles around power lines automatically, and the designed power line inspection system is effective in complex backgrounds, and there are no missing detection instances under different conditions.

  20. Power capability in low voltage dc distribution systems

    National Research Council Canada - National Science Library

    CO Gecan; Chindris; R Bindiu

    2009-01-01

    ... a LVDC distribution system. The paper presents some general considerations regarding cables used in a LVAC distribution system and different line reconfigurations witch enable the use of cobles in a LVDC distribution system...

  1. Grid Voltage Modulated Direct Power Control for Grid Connected Voltage Source Inverters

    DEFF Research Database (Denmark)

    Gui, Yonghao; Kim, Chunghun; Chung, Chung Choo

    2017-01-01

    -loop system is exponentially stable in the whole operating range. The proposed method is verified by using MATLAB/Simulink with PLECS blockset. The simulation results show that the proposed method has not only good tracking performances in both active and reactive powers but also a lower current total...

  2. Supply Voltage Decision Methodology to Minimize SRAM Standby Power Under Radiation Environment

    Science.gov (United States)

    Galib, Md Mehedi Hassan; Chang, Ik Joon; Kim, Jinsang

    2015-06-01

    In static random access memory, standby power is the summation of scrubbing and leakage powers. In terrestrial environments, the leakage power is more dominant than the scrubbing power. Hence, the conventional methodology to reduce SRAM standby power is to lower VDD to possible minimum voltage under process, voltage, and temperature variations. However, under severe radiation environments such as space, high scrubbing rate is indispensable to prevent the accumulation of soft-errors, making the scrubbing power have a substantial portion of total standby power. Since the soft-error rate becomes higher with the VDD scaling, the conventional methodology may not be valid under radiation environments. We present a methodology to decide optimal supply voltage with respect to standby power under radiation. We visualize our methodology under solar max/min galactic cosmic ray radiation environment of geosynchronous earth orbit and three error correction code (ECC) scenarios: Hamming code, double-error-correction (DEC) Bose-Chaudhuri-Hocquenghem (BCH) code, and triple-error-correction (TEC) BCH code. In 65 nm CMOS, Hamming code fails to deliver our target decoded bit-error-rate. Under other ECCs, the proposed methodology shows that 0.97 V (for DEC BCH) and 0.8 V (for TEC BCH) are optimal. Here, we can obtain 30% (for DEC BCH) and 60% (for TEC BCH) standby power savings compared to nominal voltage (= 1.2 V), respectively.

  3. Transmission Lines or Poles, Electric - VOLUSIA COUNTY MAJOR POWER LINES (Arcs)

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Volusia County Power Line data was aggregated by using parcel data and visual inspection of 2005 aerial photography to determine centerline of Power Lines Right of...

  4. Active Rectifier with Extended Functions: An Option to Voltage Sags Ride Through and Power Quality Improvement

    Directory of Open Access Journals (Sweden)

    Echavarría–Solís R.

    2010-07-01

    Full Text Available The power quality concept, is usually confused with energy saving. However, even if energy saving is desirable over all in industry applications, the first concept does not implie the second one. For the electrical engineers, the improvement of power quality using the existing converters is a great challenge. This paper deals with a multilevel, single phase active rectifier whose main objective is to compensate power factor which, with an adequate control, provides voltage sag compensation and power quality conditioning

  5. Overview of power converter designs feasible for high voltage transformer-less wind turbine

    DEFF Research Database (Denmark)

    Sztykiel, Michal

    2011-01-01

    Many leading wind turbine manufacturers are pushing forward in variable-speed wind turbines, often exceeding 5 MW. Therefore, novel designs and concepts for optimal high power wind turbines appeared. One of the most promising concepts is the high voltage (10-35 kV) transformer-less topology. High...... topology along with an overview of most promising candidates for optimal full-scale power converter design. Study is carried with proposed and justified high voltage wind turbine application along with selection of existing and most promising multilevel power converter topologies, which could...

  6. Design of high voltage DC power supply based on LCC resonant converter

    Science.gov (United States)

    Wang, Z. Q.; Liu, Z. G.; Wang, J. J.; Li, G. F.

    2013-03-01

    The aim of this paper is to design a small size, light weight high frequency high voltage (HFHV) power supply. It presents a comprehensive procedure for designing a high output voltage power supply based on series-parallel (LCC) resonant converter, aiming to realize the soft-switching. Through mathematical calculation based on an extensive of the first harmonic analysis, the paper derives the approach of determining the resonant parameters of the LCC converter. Then, a 35 kV power supply featuring a series-parallel resonant converter topology to compensate the distributed parameter is built to verify the correctness of the theory.

  7. Opposition-Based Improved PSO for Optimal Reactive Power Dispatch and Voltage Control

    Directory of Open Access Journals (Sweden)

    Shengrang Cao

    2015-01-01

    Full Text Available An opposition-based improved particle swarm optimization algorithm (OIPSO is presented for solving multiobjective reactive power optimization problem. OIPSO uses the opposition learning to improve search efficiency, adopts inertia weight factors to balance global and local exploration, and takes crossover and mutation and neighborhood model strategy to enhance population diversity. Then, a new multiobjective model is built, which includes system network loss, voltage dissatisfaction, and switching operation. Based on the market cost prices, objective functions are converted to least-cost model. In modeling process, switching operation cost is described according to the life cycle cost of transformer, and voltage dissatisfaction penalty is developed considering different voltage quality requirements of customers. The experiment is done on the new mathematical model. Through the simulation of IEEE 30-, 118-bus power systems, the results prove that OIPSO is more efficient to solve reactive power optimization problems and the model is more accurate to reflect the real power system operation.

  8. Voltage and Frequency Control for Future Power Systems: the ELECTRA IRP Proposal

    DEFF Research Database (Denmark)

    D’hulst, R.; Merino Fernandez, J.; Rikos, E.

    2015-01-01

    In this paper a high level functional architecture for frequency and voltage control for the future (2030+) power system is presented. The proposal suggests a decomposition of the present organization of power system operation into a ”web of cells”. Each cell in this web is managed by a single...

  9. Electrical Power Supply to Offshore Oil Installations by High Voltage Direct Current Transmission

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, Joergen Chr.

    2001-07-01

    of the main features when the details of the transients are of less importance. The study indicates that power supply by HVDC transmission from land to offshore oil installations could be technically feasible, even without the large synchronous compensators normally required. It has been shown that in a network only supplied by an inverter, variations of active and reactive loads have significant influence on both voltage and frequency. Particularly it should be noted that the frequency shows a positive sensitivity to increases in load. This could make the system intrinsically unstable in the case of a frequency dependent load such as motors. It was not a part of the study to optimize controllers, but even with simple controllers it was possible to keep the frequency within limits given by norms and regulations, but the voltages were dynamically outside the limits, though not very far. These voltage overswings take place in the first few instances after a disturbance, so it takes unrealistically fast controllers to handle them. They are partly due to the model, where the land based rectifier and the DC reactors are simulated by a constant current source, but partly they have to be handled by overdimensioning of the system. The simulations indicate that it should be technically possible to supply an oil platform with electrical power from land by means of HVDC transmission with small synchronous compensators. Whether this is financially feasible has not been investigated. Neither has it been considered whether the necessary equipment can actually be installed on an oil platform. Recently both ABB and Siemens have presented solutions for HVDC transmission in the lower and medium power range based on voltage source converters based on IGBTs. Fully controllable voltage source HVDC converters have properties that may be better suited than conventional line commutated current source thyristor inverters, to supply weak or passive networks, such as offshore oil installations

  10. Detecting Power Voltage Dips using Tracking Filters - A Comparison against Kalman

    Directory of Open Access Journals (Sweden)

    STANCIU, I.-R.

    2012-11-01

    Full Text Available Due of its significant economical impact, Power-Quality (PQ analysis is an important domain today. Severe voltage distortions affect the consumers and disturb their activity. They may be caused by short circuits (in this case the voltage drops significantly or by varying loads (with a smaller drop. These two types are the PQ currently issues. Monitoring these phenomena (called dips or sags require powerful techniques. Digital Signal Processing (DSP algorithms are currently employed to fulfill this task. Discrete Wavelet Transforms, (and variants, Kalman filters, and S-Transform are currently proposed by researchers to detect voltage dips. This paper introduces and examines a new tool to detect voltage dips: the so-called tracking filters. Discovered and tested during the cold war, they can estimate a parameter of interest one-step-ahead based on the previously observed values. Two filters are implemented. Their performance is assessed by comparison against the Kalman filter?s results.

  11. Assumption or Fact? Line-to-Neutral Voltage Expression in an Unbalanced 3-Phase Circuit during Inverter Switching

    Science.gov (United States)

    Masrur, M. A.

    2009-01-01

    This paper discusses the situation in a 3-phase motor or any other 3-phase system operating under unbalanced operating conditions caused by an open fault in an inverter switch. A dc voltage source is assumed as the input to the inverter, and under faulty conditions of the inverter switch, the actual voltage applied between the line to neutral…

  12. Power System State Estimation Accuracy Enhancement Using Temperature Measurements of Overhead Line Conductors

    Directory of Open Access Journals (Sweden)

    Wydra Michał

    2016-06-01

    Full Text Available Power system state estimation is a process of real-time online modeling of an electric power system. The estimation is performed with the application of a static model of the system and current measurements of electrical quantities that are encumbered with an error. Usually, a model of the estimated system is also encumbered with an uncertainty, especially power line resistances that depend on the temperature of conductors. At present, a considerable development of technologies for dynamic power line rating can be observed. Typically, devices for dynamic line rating are installed directly on the conductors and measure basic electric parameters such as the current and voltage as well as non-electric ones as the surface temperature of conductors, their expansion, stress or the conductor sag angle relative to the plumb line. The objective of this paper is to present a method for power system state estimation that uses temperature measurements of overhead line conductors as supplementary measurements that enhance the model quality and thereby the estimation accuracy. Power system state estimation is presented together with a method of using the temperature measurements of power line conductors for updating the static power system model in the state estimation process. The results obtained with that method have been analyzed based on the estimation calculations performed for an example system - with and without taking into account the conductor temperature measurements. The final part of the article includes conclusions and suggestions for the further research.

  13. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-04-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The power supply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to the indispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer need considering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, but also parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits a simple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with stray capacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only a precise measurement procedure but also effective design information for series-load resonant converter. The plasma discharging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit model of the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasma generator is built and the designing procedures for appropriate selections of the corresponding resonant-circuit parameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along with a 22 kHz and over 8kV output, is realized and implemented.

  14. Study of the plasma interference with high voltage electrode array for space power application

    OpenAIRE

    Iwasa, Minoru; Tanaka, Koji; Sasaki, Susumu; Odawara, Osamu; 岩佐 稔; 田中 孝治; 佐々木 進; 小田原 修

    2005-01-01

    We are studying the problems associated with high voltage power systems in space. Especially we are interested in the potential distribution of the solar array that is resistant to the electrical discharge. We have carried out experiments on the interaction between the high voltage solar array and the ambient plasma. In the experiment, an array of electrodes distributed on the insulation panel was used to simulate the inter-connectors of the solar array. An electrode array without the insulat...

  15. Low Voltage Ride-Through of Two-Stage Grid-Connected Photovoltaic Systems Through the Inherent Linear Power-Voltage Characteristic

    DEFF Research Database (Denmark)

    Yang, Yongheng; Sangwongwanich, Ariya; Liu, Hongpeng

    2017-01-01

    automatically through a proportional controller according to the voltage sag level and PV inherent characteristics (i.e., the voltage and power droop). Compared to prior-art LVRT schemes, the proposed method is cost-effective, as it is achieved by simply plugging the proportional controller into a maximum power......In this paper, a cost-effective control scheme for two-stage grid-connected PhotoVoltaic (PV) systems in Low Voltage Ride-Through (LVRT) operation is proposed. In the case of LVRT, the active power injection by PV panels should be limited to prevent from inverter over-current and also energy...... point tracking controller without significant hardware or software modifications. In this way, the PV system will not operate at the maximum power point, whereas the inverter will not face any over-current challenge but can provide reactive power support in response to the grid voltage fault...

  16. Association between exposure to electromagnetic fields from high voltage transmission lines and neurobehavioral function in children.

    Directory of Open Access Journals (Sweden)

    Jiongli Huang

    Full Text Available BACKGROUND: Evidence for a possible causal relationship between exposure to electromagnetic fields (EMF emitted by high voltage transmission (HVT lines and neurobehavioral dysfunction in children is insufficient. The present study aims to investigate the association between EMF exposure from HVT lines and neurobehavioral function in children. METHODS: Two primary schools were chosen based on monitoring data of ambient electromagnetic radiation. A cross-sectional study with 437 children (9 to 13 years old was conducted. Exposure to EMF from HVT lines was monitored at each school. Information was collected on possible confounders and relevant exposure predictors using standardized questionnaires. Neurobehavioral function in children was evaluated using established computerized neurobehavioral tests. Data was analyzed using multivariable regression models adjusted for relevant confounders. RESULTS: After controlling for potential confounding factors, multivariable regression revealed that children attending a school near 500 kV HVT lines had poorer performance on the computerized neurobehavioral tests for Visual Retention and Pursuit Aiming compared to children attending a school that was not in close proximity to HVT lines. CONCLUSIONS: The results suggest long-term low-level exposure to EMF from HVT lines might have a negative impact on neurobehavioral function in children. However, because of differences in results only for two of four tests achieved statistical significance and potential limitations, more studies are needed to explore the effects of exposure to extremely low frequency EMF on neurobehavioral function and development in children.

  17. Association between exposure to electromagnetic fields from high voltage transmission lines and neurobehavioral function in children.

    Science.gov (United States)

    Huang, Jiongli; Tang, Tiantong; Hu, Guocheng; Zheng, Jing; Wang, Yuyu; Wang, Qiang; Su, Jing; Zou, Yunfeng; Peng, Xiaowu

    2013-01-01

    Evidence for a possible causal relationship between exposure to electromagnetic fields (EMF) emitted by high voltage transmission (HVT) lines and neurobehavioral dysfunction in children is insufficient. The present study aims to investigate the association between EMF exposure from HVT lines and neurobehavioral function in children. Two primary schools were chosen based on monitoring data of ambient electromagnetic radiation. A cross-sectional study with 437 children (9 to 13 years old) was conducted. Exposure to EMF from HVT lines was monitored at each school. Information was collected on possible confounders and relevant exposure predictors using standardized questionnaires. Neurobehavioral function in children was evaluated using established computerized neurobehavioral tests. Data was analyzed using multivariable regression models adjusted for relevant confounders. After controlling for potential confounding factors, multivariable regression revealed that children attending a school near 500 kV HVT lines had poorer performance on the computerized neurobehavioral tests for Visual Retention and Pursuit Aiming compared to children attending a school that was not in close proximity to HVT lines. The results suggest long-term low-level exposure to EMF from HVT lines might have a negative impact on neurobehavioral function in children. However, because of differences in results only for two of four tests achieved statistical significance and potential limitations, more studies are needed to explore the effects of exposure to extremely low frequency EMF on neurobehavioral function and development in children.

  18. Principles for construction the compensators of reactive power with voltage stabilization for transformer substations

    Science.gov (United States)

    Vlasayevsky, Stanislav; Klimash, Stepan; Klimash, Vladimir

    2017-10-01

    Based on the booster transformer and the transistor converter with a DC link, a system is proposed for fast and accurate unloading the electric network from reactive power with simultaneous stabilization of voltage among consumers. The system contains a discrete stage of reactive power compensation and adjustable part. The adjustable part includes series and parallel reactive power compensators. The series compensator consists of a booster transformer, a voltage inverter and is designed to be switched on to the high voltage of the transformer substations. The parallel compensator consists of a rectifier with an input choke and is connected to the low voltage of the substation. The rectifier and inverter are connected by a DC link with an LC filter. The rectifier regulates the output voltage and the phase of the sinusoidal input current. The inverter regulates the magnitude and phase of the voltage on the control winding of the booster transformer. The rectifier and inverter control systems are synchronized with the network and with pulse width modulation.

  19. Improving voltage stability by utilizing reactive power injection capability of variable speed wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Ullah, N.R.; Thiringer, T. [Chalmer Univ. of Technology, Goteborg (Sweden). Dept. of Energy and Environment

    2008-07-01

    The effect of wind power generation on voltage stability was investigated by studying various reactive power control algorithms in combination with different wind power systems. The impact of reactive power injection by the systems on steady-state power transfer limits was analyzed. Critical load and wind generation situations were also determined. A power system model based on the Swedish transmission system was used. The wind farm installation was connected to ta 400 kV transmission grid. Four different wind turbine systems were considered: (1) traditional fixed speed; (2) variable speed wind turbine producing active power at unity power factor; (3) a variable speed turbine with a full power grid side converter; and (4) a wind turbine system with a large grid side converter. Simulations were conducted to consider the tap changing action of the transformer for all 4 types of wind turbine. Results of the study showed that use of the reactive power injection capability of wind turbine systems can increase the grid voltage stability limit. The wind farm also assisted in delaying voltage collapse events and prevented the transformer's tap from operating. It was concluded that the use of grid side converters substantially improved maximum deliverable loads. 14 refs., 2 tabs., 15 figs.

  20. Modeling of the power cable production line

    Energy Technology Data Exchange (ETDEWEB)

    Kosar, Vanja; Gomzi, Zoran [Faculty of Chemical Engineering and Technology, Department of Reaction Engineering and Catalysis, University of Zagreb, Savska c. 16, HR-10000 Zagreb (Croatia)

    2007-06-15

    During the manufacturing of a power cable insulated with the cross-linkable polyethylene, the hot polymer is applied to the conductor by extrusion, below temperatures of the rapid cross-linking. The coated cable passes into a high-pressure tube (filled with nitrogen under the pressure of 10 bar) in order to heat up the insulation to temperatures at which the cross-linking agent is highly active. This is the continuous vulcanization (CV) tube. Changes of process variables associated with the CV tube can cause changes in the physical properties, the aging characteristics, and especially the heat resistance of the cable insulation. Performance of insulating compounds in this area of the cross-linking process can determine maximum output rates of a power cable manufacturing facility. The mathematical model describes cross-linking process in the vulcanization tube, which is in fact a tubular reactor. In the vulcanization tube heat is transferred by convection, conduction and radiation. Also, the reaction heat is liberated by the chemical reaction and the heat balance describes all four impacts. Formal part of the mathematical model is a material balance that describes the reactions kinetics. Heat and mole balance are connected with reaction rate and mathematically present a system of partial differential equations which will be numerically solved for chosen boundary conditions, both for the reaction part and for the cooling part of a process. On the basis of the real process parameters and the presented mathematical model simulation of the process was conducted. From the presented simulation the optimal process parameters such as process temperatures, cable linear velocity (u) and cable cooling properties of CV line are predicted and evaluated. (author)

  1. Electric and magnetic field of different transpositions of overhead power line

    Directory of Open Access Journals (Sweden)

    Deltuva Ramūnas

    2017-09-01

    Full Text Available In Lithuanian and Polish electric power supply systems, the power transmission lines of 400 kV voltage represent one of the most potential sources of electric and magnetic fields generation. The 400 kV double-circuit overhead power transmission line and its surrounding environment were herby described and simulated through Finite Element Method using COMSOL Multiphysic software package. This study includes magnetic and electric field calculations. The study shows that the values of magnetic field strength and electric field strength present in the vicinity of a 400 kV overhead power transmission line tend to exceed limit values established in the Normative. Measurements are suggested to be taken for the purpose of finding maximum values of magnetic and electric field strength. To reduce these values, it is recommended to increase the height of supports, and restrict human personal and economic activities.

  2. The Use of Energy Storage Systems for Supporting the Voltage Needs of Urban and Suburban Railway Contact Lines

    Directory of Open Access Journals (Sweden)

    Enrico Pagano

    2013-03-01

    Full Text Available The paper aims to contribute to the use of electric double layer capacitor (EDLC sets for boosting voltages of contact lines in urban and suburban railway traction systems. Different electrical configurations of contact lines are considered and investigated. For each of them, proper mathematical models are suggested to evaluate the electrical performances of the contact lines. They give rise, also, to sample design procedures for the sizing of the most appropriate energy storage systems, to be distributed along the lines, for boosting line voltages and avoiding undesired voltage drops. A numerical example based on the “Cumana” suburban Naples railway network is presented to give an idea of the weights and sizes of electric double layer capacitors needed to boost the voltage of a sample contact line. In particular, three different EDLC systems, for a overall installed energy of 9.6 kWh, have been placed nearby the stations presenting the highest voltage drops during the most representative situation of trains’ service. The new voltage drop is equal to 32% of that obtained in absence of EDLCs.

  3. The prediction and prevention of voltage collapse in the Finnish power system

    Energy Technology Data Exchange (ETDEWEB)

    Bastman, J.; Lakervi, E. [Tampere Univ. of Tech. (Finland); Hirvonen, R.; Kuronen, P.; Hagman, E. [IVO Group (Finland)

    1994-12-31

    The Finnish power system is a part of the Nordic power system (NORDEL), which includes Finland, Sweden, Norway and the eastern part of Denmark. In NORDEL the transmission distances are long, which implies that the power transmission capacities are determined by stability criteria . The methods to prevent and predict the voltage collapse during severe disturbances are studied using advances simulation program. Results are presented. (author) 10 figs., 1 tab.

  4. Distributed Optimal Control of Reactive Power and Voltage in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe

    2017-01-01

    This paper presents a distributed optimal control strategy for islanded microgrids, which allows to perform reactive power sharing and voltage regulation without using communication system. To perform the twofold objectives, a small signal model is first developed to reconstruct the system input...... performance of the optimal controller is analyzed, from which the guideline for choosing controller parameters is formulated. The results obtained from sensitivity analysis, simulations and experiments show that the proposed approach provides the expected reliability and flexibility for optimizing......-output relationship, which is evaluated through sensitivity analysis. A state estimator is then constructed to observe reactive power distribution and system voltages by local measurement. An optimal regulator is developed to perform both reactive power sharing and system voltage restoration. And the dynamic...

  5. Distributed Optimal Control of Reactive Power and Voltage in Islanded Microgrids

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe

    2016-01-01

    The paper proposes a distributed optimal control strategy for islanded microgrids, which allows to perform reactive power sharing and voltage regulation without communication system. To realize the twofold objective, an improved small signal model is developed first to reconstruct the system input...... power sharing and system voltage restoration. And the dynamic performance of the optimal controller is analyzed, from which the guideline for choosing controller parameters is formulated. The results obtained from sensitivity analysis, simulations and experiments show that the proposed approach provides......-output relationship, where the relationship is evaluated with sensitivity analysis. A state estimator is then constructed based on the new input-output relationship in order to observe reactive power distribution and system voltages by local measurement. An optimal regulator is developed to perform both reactive...

  6. An evaluation method of voltage sag using a risk assessment model in power distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Sang Yun Yun [LG Industrial Systems, Cheongju (Korea). Electrotechnology R and D Center; Jae Chul Kim [Soongsil Univ., Seoul (Korea). Dept. of Electrical Engineering

    2003-12-01

    In this paper we explore a new method for evaluating the impact of voltage sags in the power distribution systems. The proposed method incorporates the generalization of the evaluation method as well as the effects of voltage sags on customers. To generalize the evaluation method, historical reliability data will be used. We take into account the impact of voltage sags on customers using a representative power acceptability curve and a fuzzy model. The final result of the evaluation model yields on a yearly basis the magnitude of customers' risk caused by voltage sags. The evaluation methodology is divided into the analytic and probabilistic method. The time sequential Monte Carlo simulation is used as probabilistic method. The proposed method is tested using the modified Roy Billinton Test System (RBTS) form and the reliability data of Korea Electric Power Corporation (KEPCO) system. Through the case study, we verify that the proposed method evaluate the actual impact of voltage sags and can be effectively applied to the real system using the historical reliability data as the conventional reliability indices in power distribution systems. (author)

  7. Characterization of low temperature high voltage axial insulator breaks for the ITER cryogenic supply line

    Science.gov (United States)

    Fernandez Pison, P.; Sgobba, S.; Aviles Santillana, I.; Langeslag, S. A. E.; Su, M.; Piccin, R.; Journeaux, J. Y.; Laurenti, A.; Pan, W.

    2017-12-01

    Cable-in-conduit conductors of the ITER magnet system are directly cooled by supercritical helium. Insulation breaks are required in the liquid helium feed pipes to isolate the high voltage system of the magnet windings from the electrically grounded helium coolant supply line. They are submitted to high voltages and significant internal helium pressure and will experience mechanical forces resulting from differential thermal contraction and electro-mechanical loads. Insulation breaks consist essentially of stainless steel tubes overwrapped by an outer glass – fiber reinforced composite and bonded to an inner composite tube at each end of the stainless steel fittings. For some types of insulator breaks Glass – Kapton – Glass insulation layers are interleaved in the outer composite. Following an extensive mechanical testing campaign at cryogenic temperature combined with leak tightness tests, the present paper investigates through non-destructive and destructive techniques the physical and microstructural characteristics of the low temperature high voltage insulation breaks and of their individual components, thus allowing to correlate the structure and properties of the constituents to their overall performance. For all the tests performed, consistent and reproducible results were obtained within the range of the strict acceptance criteria defined for safe operation of the insulation breaks.

  8. Topics in high voltage pulsed power plasma devices and applications

    Science.gov (United States)

    Chen, Hao

    Pulsed power technology is one of the tools that is used by scientists and engineers nowadays to produce gas plasmas. The transient ultra high power is able to provide a huge pulse of energy which is sometimes greater than the ionization energy of the gas, and therefore separates the ions and electrons to form the plasma. Sometimes, the pulsed power components themselves are plasma devices. For example, the gas type switches can "turn on" the circuit by creating the plasma channel between the switch electrodes. Mini Back Lighted Thyratron, or as we call it, mini-BLT, is one of these gas type plasma switches. The development of the reduced size and weight "mini-BLT" is presented in this dissertation. Based on the operation characteristics testing of the mini-BLT, suggestions of optimizing the design of the switch are proposed. All the factors such as the geometry of the hollow electrodes and switch housing, the gas condition, the optical triggering source, etc. are necessary to consider when we design and operate the mini-BLT. By reducing the diameter of the cylindrical gas path between the electrodes in the BLT, a novel high density plasma source is developed, producing the plasma in the "squeezed" capillary. The pulsed power generator, of course, is inevitably used to provide the ionization energy for hydrogen gas sealed in the capillary. Plasma diagnostics are necessarily analyzed and presented in detail to properly complete and understand the capillary plasma. This high density plasma source (1019 cm-3) has the potential applications in the plasma wakefield accelerator. The resonant oscillation behavior of the particles in plasmas allows for dynamically generated accelerating electric fields that have orders of magnitude larger than those available in the conventional RF accelerators. Finally, the solid state switches are introduced as a comparison to the gas type switch. Pulsed power circuit topologies such as the Marx Bank, magnetic pulse compression and diode

  9. Power System Decomposition for Practical Implementation of Bulk-Grid Voltage Control Methods

    Energy Technology Data Exchange (ETDEWEB)

    Vallem, Mallikarjuna R.; Vyakaranam, Bharat GNVSR; Holzer, Jesse T.; Elizondo, Marcelo A.; Samaan, Nader A.

    2017-10-19

    Power system algorithms such as AC optimal power flow and coordinated volt/var control of the bulk power system are computationally intensive and become difficult to solve in operational time frames. The computational time required to run these algorithms increases exponentially as the size of the power system increases. The solution time for multiple subsystems is less than that for solving the entire system simultaneously, and the local nature of the voltage problem lends itself to such decomposition. This paper describes an algorithm that can be used to perform power system decomposition from the point of view of the voltage control problem. Our approach takes advantage of the dominant localized effect of voltage control and is based on clustering buses according to the electrical distances between them. One of the contributions of the paper is to use multidimensional scaling to compute n-dimensional Euclidean coordinates for each bus based on electrical distance to perform algorithms like K-means clustering. A simple coordinated reactive power control of photovoltaic inverters for voltage regulation is used to demonstrate the effectiveness of the proposed decomposition algorithm and its components. The proposed decomposition method is demonstrated on the IEEE 118-bus system.

  10. Nonlinear control of voltage source converters in AC-DC power system.

    Science.gov (United States)

    Dash, P K; Nayak, N

    2014-07-01

    This paper presents the design of a robust nonlinear controller for a parallel AC-DC power system using a Lyapunov function-based sliding mode control (LYPSMC) strategy. The inputs for the proposed control scheme are the DC voltage and reactive power errors at the converter station and the active and reactive power errors at the inverter station of the voltage-source converter-based high voltage direct current transmission (VSC-HVDC) link. The stability and robust tracking of the system parameters are ensured by applying the Lyapunov direct method. Also the gains of the sliding mode control (SMC) are made adaptive using the stability conditions of the Lyapunov function. The proposed control strategy offers invariant stability to a class of systems having modeling uncertainties due to parameter changes and exogenous inputs. Comprehensive computer simulations are carried out to verify the proposed control scheme under several system disturbances like changes in short-circuit ratio, converter parametric changes, and faults on the converter and inverter buses for single generating system connected to the power grid in a single machine infinite-bus AC-DC network and also for a 3-machine two-area power system. Furthermore, a second order super twisting sliding mode control scheme has been presented in this paper that provides a higher degree of nonlinearity than the LYPSMC and damps faster the converter and inverter voltage and power oscillations. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  11. Reactive Power Compensation of a 24 MW Wind Farm using a 12-Pulse Voltage Source Converter

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen; Pedersen, Jørgen Kaas

    1998-01-01

    Integration of large wind farms in distribution and transmission systems may have severe influence on the power quality at the connection point and may also influence the voltage controlling capability of the electrical system. The purpose of the described project has been to develop and investig......Integration of large wind farms in distribution and transmission systems may have severe influence on the power quality at the connection point and may also influence the voltage controlling capability of the electrical system. The purpose of the described project has been to develop...... and investigate the use of a STATCOM by modelling and field testing an 8 MVar unit in a 24 MW wind farm....

  12. Characterization and assessment of voltage and power constraints of DFIG WT connected to a weak network

    DEFF Research Database (Denmark)

    Abulanwar, Elsayed; Hu, Weihao; Iov, Florin

    2014-01-01

    of common coupling, PCC, and maximize the wind power penetration into weak networks. As a basis of investigation, a simplified system model is utilized and the respective PCC voltage, active and reactive power stability issues are identified. Besides, a steady-state study for DFIG WT connected to a weak......This article thoroughly investigates the challenges and constraints raised by the integration of a Doubly-fed Induction generator wind turbine, DFIG WT, into an ac network of extensively varying parameters and very weak conditions. The objective is to mitigate the voltage variations at the point...

  13. Apparatus and Method for Compensating for Process, Voltage, and Temperature Variation of the Time Delay of a Digital Delay Line

    Science.gov (United States)

    Seefeldt, James (Inventor); Feng, Xiaoxin (Inventor); Roper, Weston (Inventor)

    2013-01-01

    A process, voltage, and temperature (PVT) compensation circuit and a method of continuously generating a delay measure are provided. The compensation circuit includes two delay lines, each delay line providing a delay output. The two delay lines may each include a number of delay elements, which in turn may include one or more current-starved inverters. The number of delay lines may differ between the two delay lines. The delay outputs are provided to a combining circuit that determines an offset pulse based on the two delay outputs and then averages the voltage of the offset pulse to determine a delay measure. The delay measure may be one or more currents or voltages indicating an amount of PVT compensation to apply to input or output signals of an application circuit, such as a memory-bus driver, dynamic random access memory (DRAM), a synchronous DRAM, a processor or other clocked circuit.

  14. Multiloop Rapid-Rise/Rapid Fall High-Voltage Power Supply

    Science.gov (United States)

    Bearden, Douglas

    2007-01-01

    A proposed multiloop power supply would generate a potential as high as 1.25 kV with rise and fall times rise-time, and fall-time requirements. The power supply would include a preregulator that would be used to program a voltage 1/30 of the desired output voltage. By means of a circuit that would include a pulse-width modulator (PWM), two voltage doublers, and a transformer having two primary and two secondary windings, the preregulator output voltage would be amplified by a factor of 30. A resistor would limit the current by controlling a drive voltage applied to field-effect transistors (FETs) during turn-on of the PWM. Two feedback loops would be used to regulate the high output voltage. A pulse transformer would be used to turn on four FETs to short-circuit output capacitors when the outputs of the PWM were disabled. Application of a 0-to-5-V square to a PWM shut-down pin would cause a 20-to-1,250-V square wave to appear at the output.

  15. On-state voltage drop based power limit detection of IGBT inverters

    DEFF Research Database (Denmark)

    Trintis, Ionut; Ghimire, Pramod; Munk-Nielsen, Stig

    2015-01-01

    insulated gate bipolar transistors (IGBTs) in the inverter, using advanced gate driver. The die temperature is estimated and monitored on each device during power converter operation. Based on the monitored temperature in real time, the maximum power capability is detected. The output power is increased......Power density is a key performance factor in order to reduce the cost and size of a power converter. Because of the unknown junction temperature, today’s design margins are relatively high to ensure safe and a reliable operation. In this paper, the on-state voltage drop is measured online for all...

  16. Design of Plasma Generator Driven by High-frequency High-voltage Power Supply

    Directory of Open Access Journals (Sweden)

    C. Yong-Nong

    2013-03-01

    Full Text Available In this research, a high-frequency high-voltage power supply designed for plasma generator is presented. The powersupply mainly consists of a series resonant converter with a high-frequency high-voltage boost transformer. Due to theindispensable high-voltage inheritance in the operation of plasma generator, the analysis of transformer needconsidering not only winding resistance, leakage inductance, magnetizing inductance, and core-loss resistance, butalso parasitic capacitance resulted from the insulation wrappings on the high-voltage side. This research exhibits asimple approach to measuring equivalent circuit parameters of the high-frequency, high-voltage transformer with straycapacitance being introduced into the conventional modeling. The proposed modeling scheme provides not only aprecise measurement procedure but also effective design information for series-load resonant converter. The plasmadischarging plate is designed as part of the electric circuit in the series load-resonant converter and the circuit modelof the plasma discharging plate is also conducted as well. Thus, the overall model of the high-voltage plasmagenerator is built and the designing procedures for appropriate selections of the corresponding resonant-circuitparameters can be established. Finally, a high-voltage plasma generator with 220V, 60Hz, and 1kW input, along witha 22 kHz and over 8kV output, is realized and implemented.

  17. Optimal Placement of Unified Power Flow Controllers : An Approach to Maximize the Loadability of Transmission Lines

    Directory of Open Access Journals (Sweden)

    S. T. Jaya Christa

    2006-06-01

    Full Text Available This paper deals with the optimal location and parameters of Unified Power Flow Controllers (UPFCs in electrical power systems, using particle swarm optimization (PSO. The objective is to maximize the transmission system loadability subject to the transmission line capacity limits and specified bus voltage levels. Using the proposed method, the location of UPFCs and their parameters are optimized simultaneously. PSO is used to solve the above non-linear programming problem for better accuracy. The proposed approach is examined and tested on IEEE 30-bus system and IEEE 118-bus system. The results obtained are quite promising for the power system operation environment

  18. DEVELOPMENT OF HIGH-VOLTAGE HIGH-FREQUENCY POWER SUPPLY FOR OZONE GENERATION

    Directory of Open Access Journals (Sweden)

    NACERA HAMMADI

    2016-05-01

    Full Text Available A high-voltage high-frequency power supply for ozone generation is presented in this paper. Ozone generation is intended to be used in air and in water disinfection. A power stage consisting of a single-phase full bridge inverter for regulating the output power, a current push-pull inverter (driver and a control circuit are described and analyzed. This laboratory build power supply using a high voltage ferrite transformer and a PIC microcontroller was employed to energize a dielectric barrier discharge (DBD ozone generator. The inverter working on the basis of control strategy is of simple structure and has a variation range of the working frequency in order to obtain the optimal frequency value. The experimental results concerning electrical characterization and water treatment using a cylindrical DBD ozone generator supplied by this power supply are given in the end.

  19. Mechanism of the tonal emission from ac high voltage overhead transmission lines

    Science.gov (United States)

    Straumann, Ueli

    2011-02-01

    Foul weather conditions can lead to corona discharges on high voltage overhead transmission lines which are perceivable as an audible broadband crackling and hissing noise. In such situations this noise is often accompanied by a humming noise at twice the mains frequency (2f). While the crackling and hissing noise component was widely investigated in the past, the 2f-component went largely uncommented. Only a scant amount of literature suggests mechanisms explaining the occurrence of this emission, but these suggestions are either vague or controversial. In this paper a mechanism analogous to that of ion loudspeakers is presented, which describes the sound levels of audible 2f-emissions from high voltage model lines quantitatively in a satisfactory manner. While the broadband component of corona noise emissions has its immediate origin in the discharges themselves, the 2f-emissions arise from the drift of ions left behind by the discharges. Due to collisions with gas molecules, these ions cause in the sum a rise of heat in and a force applying on the neutral gas, thus producing the 2f-emissions. Depending on the situation, both can give rise to contributions of similar magnitude.

  20. Marine High Voltage Power Conditioning and Transmission System with Integrated Storage DE-EE0003640 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Frank Hoffmann, PhD; Aspinall, Rik

    2012-12-10

    Design, Development, and test of the three-port power converter for marine hydrokinetic power transmission. Converter provides ports for AC/DC conversion of hydrokinetic power, battery storage, and a low voltage to high voltage DC port for HVDC transmission to shore. The report covers the design, development, implementation, and testing of a prototype built by PPS.

  1. HYBRID EVOLUTIONARY ALGORITHMS FOR FREQUENCY AND VOLTAGE CONTROL IN POWER GENERATING SYSTEM

    Directory of Open Access Journals (Sweden)

    A. Soundarrajan

    2010-10-01

    Full Text Available Power generating system has the responsibility to ensure that adequate power is delivered to the load, both reliably and economically. Any electrical system must be maintained at the desired operating level characterized by nominal frequency and voltage profile. But the ability of the power system to track the load is limited due to physical and technical consideration. Hence, a Power System Control is required to maintain a continuous balance between power generation and load demand. The quality of power supply is affected due to continuous and random changes in load during the operation of the power system. Load Frequency Controller (LFC and Automatic Voltage Regulator (AVR play an important role in maintaining constant frequency and voltage in order to ensure the reliability of electric power. The fixed gain PID controllers used for this application fail to perform under varying load conditions and hence provide poor dynamic characteristics with large settling time, overshoot and oscillations. In this paper, Evolutionary Algorithms (EA like, Enhanced Particle Swarm Optimization (EPSO, Multi Objective Particle Swarm Optimization (MOPSO, and Stochastic Particle Swarm Optimization (SPSO are proposed to overcome the premature convergence problem in a standard PSO. These algorithms reduce transient oscillations and also increase the computational efficiency. Simulation results demonstrate that the proposed controller adapt themselves appropriate to varying loads and hence provide better performance characteristics with respect to settling time, oscillations and overshoot.

  2. The Rated Voltage Determination of DC Building Power Supply System Considering Human Beings Safety

    Science.gov (United States)

    Wang, Zhicheng; Yu, Kansheng; Xie, Guoqiang; Zou, Jin

    2018-01-01

    Generally two-level voltages are adopted for DC building power supply system. From the point of view of human beings safety, only the lower level voltage which may be contacted barehanded is discussed in this paper based on the related safety thresholds of human beings current effect. For several voltage levels below 100V recommended by IEC, the body current and current density of human electric shock under device normal work condition, as well as effect of unidirectional single impulse currents of short durations are calculated and analyzed respectively. Finally, DC 60V is recommended as the lower level rating voltage through the comprehensive consideration of technical condition and cost of safety criteria.

  3. An improved control method of power electronic converters in low voltage micro-grid

    DEFF Research Database (Denmark)

    Xiaofeng, Sun; Qingqiu, Lv; Yanjun, Tian

    2011-01-01

    With the increasing acceptance, micro-grid, combined with distributed generation (DG), may be operated in two modes: grid-connected mode and island mode. In grid connected mode, energy management is the control objective. While in island mode, the control of Voltage and frequency will take...... the place. The conventional droop control can perform the energy management in grid-connected mode, but may not so effective when micro-grid transferring between grid-connected mode and island mode. The paper analysis the micro-grid in different modes (Conventional droop control, Voltage reference...... compensation, Constant power output mode, Phase adjustment mode), and then proposes an overall control strategy for the micro-grid. The voltage reference compensation would minimize the steady-state error on the nominated operation point; the coordinate control of voltage and frequency with a feed forward...

  4. Voltage control and protection in electrical power systems from system components to wide-area control

    CERN Document Server

    Corsi, Sandro

    2015-01-01

    Based on the author’s twenty years of experience, this book shows the practicality of modern, conceptually new, wide area voltage control in transmission and distribution smart grids, in detail. Evidence is given of the great advantages of this approach, as well as what can be gained by new control functionalities which modern technologies now available can provide. The distinction between solutions of wide area voltage regulation (V-WAR) and wide area voltage protection (V-WAP) are presented, demonstrating the proper synergy between them when they operate on the same power system as well as the simplicity and effectiveness of the protection solution in this case. The author provides an overview and detailed descriptions of voltage controls, distinguishing between generalities of underdeveloped, on-field operating applications and modern and available automatic control solutions, which are as yet not sufficiently known or perceived for what they are: practical, high-performance and reliable solutions. At th...

  5. Study of Low Voltage Ride Through Performance for Wind Power Generation with Doubly Fed Induction Generator

    Science.gov (United States)

    Hirawata, Ryoya; Kai, Takaaki

    Recently, the introduction of wind power generation is increasing rapidly. The ratio of wind power generation to the capacity of a total generation is getting higher and higher. When the phase-to-phase fault occurs in the power system, the frequency of power system is lower due to disconnecting of the wind power generation with doubly fed induction generator (DFIG). Therefore, the power system might become unstable. This paper describes the LVRT (low voltage ride through) performance improvement scheme of the wind power generation with DFIG. The wind power generation is disconnected from the grid in case of the power system fault. It is independently in operation from the grid by controlling of the inverter equipped in the generation. After clearance of the power system fault, the wind power generation is immediately re-connected to the grid. As a result, instability in the power system disappears. The performance of LVRT is confirmed by using simulation software PSCAD/EMTDC. The simulation result shows an excellent result to the three-phase short-circuit fault of the voltage dip 100%.

  6. Low-voltage grid-connection of photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Collinson, A.; Thornycroft, J.

    1999-07-01

    This report summarises the results of a project aimed at developing technical guidelines concerning grid connected photovoltaic (PV) inverter generators which are to be published in draft form as the {sup U}K Technical Guidelines for Inverter Connected Single Phase Photovoltaic (PV) Generators up to 5kVA{sup .} The background to the use of PV in the UK is traced, and the technical criteria for electrical integration of PV systems, and UK guidelines for grid connected PV systems are examined. The findings of the working group of the International Energy Agency (IEA) Implementing Agreement on Photovoltaic Power Systems are also presented in this report. Appendices discuss the UK technical guidelines, the IEA Task V activities,, utility aspects of grid-connected PV systems, and demonstration tests on grid-connected PV systems, and lists Task V reports.

  7. Adaptive Neurofuzzy Inference System-Based Pollution Severity Prediction of Polymeric Insulators in Power Transmission Lines

    OpenAIRE

    Muniraj, C.; Chandrasekar, S.

    2011-01-01

    This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out on 11 kV silicone rubber polymeric insulator under AC voltage at different pollution levels with sodium chloride as a contaminant. Leakage current was measured during the laboratory tests. Time domain and frequency domain characteristics of leak...

  8. Design of the all solid high-voltage power supply for a gyrotron body

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Yihua [School of Mathematics and Physics, University of South China, Hengyang, 421001 (China); Chen, Wenguang, E-mail: 430000485393@usc.edu.cn [School of Electrical Engineering, University of South China, Hengyang, 421001 (China); Hu, Bo [School of Electrical Engineering, University of South China, Hengyang, 421001 (China); Rao, Jun; Huang, Mei; Kang, Zihua; Feng, Kun [Southwestern Institute of Physics, Chengdu, 610041 (China); Huang, Jiaqi [School of Electrical Engineering, University of South China, Hengyang, 421001 (China)

    2017-04-15

    Highlights: • Completed design of all solid-state high-voltage power supply for gyrotron body on HL-2M ECRH. • Consist of 58 PSM modules and one BUCK module, controlled by DSP system. • Fabricated full voltage 35 kV, 200 mA BPS and tested in dummy load. • The BPS can operate in three modes: single pulse mode, multi-pulse modulation mode and the six-level preset mode. - Abstract: Gyrotron plays an important role in the research of electron cyclotron resonance heating (ECRH) on Tokomak. The high-frequency switched power supply technology and pulse step modulation (PSM) technology are used in the development of the all solid high-voltage body power supply (BPS) for 1 MW/105 GHz Gyrotron on ECRH system. Firstly, the basic structure of the BPS and its control system are introduced. Secondly, the software control algorithm of voltage stabilization and modulate method are developed. Finally, the design is verified by the experiments. The experimental results of the single pulse mode, the multi-pulse modulation mode and the six-level preset mode, are shown. The output voltage of the power supply can reach 35 kV and the current at about 200 mA, which are adjustable in the full range. The maximum modulation frequency can reach 1 kHz and the front edge of the pulse can be adjust from 0 to 3 ms and the accuracy of the output voltage is less than 100 V. The results show that the control method is feasible and can be applied to other high power microwave sources.

  9. Study on Insulation Diagnosis of Power Lines in Apartment Houses

    Science.gov (United States)

    Okamoto, Tatsuki; Taki, Shoji; Fukui, Toshiaki; Soga, Akiya; Ezure, Shoichiro; Asano, Jun-Ichi; Uto, Yukio

    Insulation diagnosis is vital issue for safety of urban lives despite of the difficulty of power interruption even for the diagnosis. Recently, live-line insulation diagnosis becomes more important and realistic to maintain good insulation conditions of power lines in apartment houses in wide range of residential sizes. This paper describes new trend of insulation diagnosis of power lines of apartment houses based on clip-on current measurement method with a lot of live-line measurement data and also describes the applicability of new live-line insulation diagnostic method.

  10. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines.

    Science.gov (United States)

    Reale, D V; Bragg, J-W B; Gonsalves, N R; Johnson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2014-05-01

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

  11. Voltage balancing in modular energy storage of power supply for micro resistance welding

    Directory of Open Access Journals (Sweden)

    Kozhushko Yu. V.

    2017-10-01

    Full Text Available Micro resistance welding is one of the most effective ways to obtain permanent joints of metal parts. The quality of welded joints strongly depends on the characteristics of the power supply of welding equipment. The power supplies for micro resistance welding based on Energy Storage topology have a softer impact on the network than the ones based on Direct Energy topology. The use of supercapacitors for Energy Storage type power supplies makes it possible to reduce the dimensions of welding equipment and to improve its technical parameters. However, the feature of the supercapacitors is low value of the nominal voltage, which usually does not exceed 3 V. To provide higher voltage, the modules of supercapacitors connected in series are designed. In order to extend the life time of such modules, a voltage balancing system is required. A circuit for balancing the voltage of a modular supercapacitor energy storage of a power supply for micro resistance welding is proposed. The fragments of calculation of control units of a supercapacitor module cell are given. The simulation of the balancing circuit operation is carried out and time charts of the supercapacitor charge process are obtained. The operability and effectiveness of the proposed solution is confirmed. The advantage of the proposed circuit is the possibility of obtaining the high efficiency because of returning the excessive energy of the module cell back into the power supply.

  12. TLBO based Voltage Stable Environment Friendly Economic Dispatch Considering Real and Reactive Power Constraints

    Science.gov (United States)

    Verma, H. K.; Mafidar, P.

    2013-09-01

    In view of growing concern towards environment, power system engineers are forced to generate quality green energy. Hence the economic dispatch (ED) aims at the power generation to meet the load demand at minimum fuel cost with environmental and voltage constraints along with essential constraints on real and reactive power. The emission control which reduces the negative impact on environment is achieved by including the additional constraints in ED problem. Presently, the power system mostly operates near its stability limits, therefore with increased demand the system faces voltage problem. The bus voltages are brought within limit in the present work by placement of static var compensator (SVC) at weak bus which is identified from bus participation factor. The optimal size of SVC is determined by univariate search method. This paper presents the use of Teaching Learning based Optimization (TLBO) algorithm for voltage stable environment friendly ED problem with real and reactive power constraints. The computational effectiveness of TLBO is established through test results over particle swarm optimization (PSO) and Big Bang-Big Crunch (BB-BC) algorithms for the ED problem.

  13. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Science.gov (United States)

    Pei, Chengquan; Tian, Jinshou; Liu, Zhen; Qin, Hong; Wu, Shengli

    2017-04-01

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  14. Adaptive Hierarchical Voltage Control of a DFIG-Based Wind Power Plant for a Grid Fault

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinho; Muljadi, Eduard; Park, Jung-Wook; Kang, Yong Cheol

    2016-11-01

    This paper proposes an adaptive hierarchical voltage control scheme of a doubly-fed induction generator (DFIG)-based wind power plant (WPP) that can secure more reserve of reactive power (Q) in the WPP against a grid fault. To achieve this, each DFIG controller employs an adaptive reactive power to voltage (Q-V) characteristic. The proposed adaptive Q-V characteristic is temporally modified depending on the available Q capability of a DFIG; it is dependent on the distance from a DFIG to the point of common coupling (PCC). The proposed characteristic secures more Q reserve in the WPP than the fixed one. Furthermore, it allows DFIGs to promptly inject up to the Q limit, thereby improving the PCC voltage support. To avert an overvoltage after the fault clearance, washout filters are implemented in the WPP and DFIG controllers; they can prevent a surplus Q injection after the fault clearance by eliminating the accumulated values in the proportional-integral controllers of both controllers during the fault. Test results demonstrate that the scheme can improve the voltage support capability during the fault and suppress transient overvoltage after the fault clearance under scenarios of various system and fault conditions; therefore, it helps ensure grid resilience by supporting the voltage stability.

  15. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Qin, Hong [School of Computer Science and Technology, Xi' an University of Science and Technology, Xi' an 710054 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2017-04-11

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  16. Analysis of Power Network for Line Reactance Variation to Improve Total Transmission Capacity

    Directory of Open Access Journals (Sweden)

    Ikram Ullah

    2016-11-01

    Full Text Available The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks. The bottlenecks cause transmission congestion, reliability problems, restrict competition, and limit the maximum dispatch of low cost generations in the network. The electricity system requires efficient utilization of the current transmission capability to improve the Available Transfer Capability (ATC. To improve the ATC, power flow among the lines can be managed by using Flexible AC Transmission System (FACTS devices as power flow controllers, which alter the parameters of power lines. It is important to place FACTS devices on suitable lines to vary the reactance for improving Total Transmission Capacity (TTC of the network and provide flexibility in the power flow. In this paper a transmission network is analyzed based on line parameters variation to improve TTC of the interconnected system. Lines are selected for placing FACTS devices based on real power flow Performance Index (PI sensitivity factors. TTC is computed using the Repeated Power Flow (RPF method using the constraints of lines thermal limits, bus voltage limits and generator limits. The reactance of suitable lines, selected on the basis of PI sensitivity factors are changed to divert the power flow to other lines with enough transfer capacity available. The improvement of TTC using line reactance variation is demonstrated with three IEEE test systems with multi-area networks. The results show the variation of the selected lines’ reactance in improving TTC for all the test networks with defined contingency cases.

  17. An Ultra-Low-Voltage and Ultra-Low-Power 2.4 GHz LNA Design

    Directory of Open Access Journals (Sweden)

    S. Guo

    2009-12-01

    Full Text Available In this paper, ultra-low-voltage and ultra-low-power circuit techniques are presented for CMOS RF front-ends. By employing a modified current-reused architecture, the low-noise amplifier (LNA can operate at a very low supply voltage with microwatt power consumption while maintaining reasonable circuit performance at 2.4 GHz. Using a TSMC 0.18 um CMOS process, from the simulation results, the fully integrated LNA exhibits a gain of 14.4 dB and a noise figure of 1.6 dB at 2.4 GHz, operated at a supply voltage of 0.9 V, the input matching (S11 is –18.1 dB while consumes only 960 μW. example.

  18. A New Fast Peak Current Controller for Transient Voltage Faults for Power Converters

    Directory of Open Access Journals (Sweden)

    Jesús Muñoz-Cruzado-Alba

    2015-12-01

    Full Text Available Power converters are the basic unit for the transient voltage fault ride through capability for most renewable distributed generators (DGs. When a transient fault happens, the grid voltage will drop suddenly and probably will also suffer a phase-jump event as well. State-of-the-art voltage fault control techniques regulate the current injected during the grid fault. However, the beginning of the fault could be too fast for the inner current control loops of the inverter, and transient over-current would be expected. In order to avoid the excessive peak current of the methods presented in the literature, a new fast peak current control (FPCC technique is proposed. Controlling the peak current magnitude avoids undesirable disconnection of the distributed generator in a fault state and improves the life expectancy of the converter. Experimental and simulation tests with high power converters provide the detailed behaviour of the method with excellent results.

  19. Dynamic response characteristics analysis of the doubly-fed wind power system under grid voltage drop

    Science.gov (United States)

    Chen, Y.; Wang, J.; Wang, H. H.; Yang, L.; Chen, W.; Xu, Y. T.

    2016-08-01

    Double-fed induction generator (DFIG) is sensitive to the disturbances of grid, so the security and stability of the grid and the DFIG itself are under threat with the rapid increase of DFIG. Therefore, it is important to study dynamic response of the DFIG when voltage drop failure is happened in power system. In this paper, firstly, mathematical models and the control strategy about mechanical and electrical response processes is respectively introduced. Then through the analysis of response process, it is concluded that the dynamic response characteristics are related to voltage drop level, operating status of DFIG and control strategy adapted to rotor side. Last, the correctness of conclusion is validated by the simulation about mechanical and electrical response processes in different voltage levels drop and different DFIG output levels under DIgSILENT/PowerFactory software platform.

  20. Power Lines and Crops Can Be Good Neighbors

    Energy Technology Data Exchange (ETDEWEB)

    None

    2010-08-01

    Two of the Pacific Northwest’s greatest economic assets are its wealth of agriculture and its clean and reliable electricity fueled largely by hydropower. Sometimes the two intersect. Transmission lines carrying electricity to the region’s farms, businesses and homes must, of necessity, span large areas where people grow crops and orchards. To ensure a safe and reliable flow of electricity across these expanses, trees and other vegetation must be managed to certain standards. At the same time, the Bonneville Power Administration — which owns and operates three-quarters of the region’s high-voltage transmission — recognizes the importance of our region’s agricultural bounty. We are committed to working with individuals and agricultural communities to facilitate ongoing land-use activities in transmission rights-of-way as long as those uses are compatible with transmission safety and reliability standards. Our goal with vegetation management is to keep you and your property safe while protecting the reliability of our region’s electricity system. By working together, BPA and landowners can protect the system and public safety.

  1. Strategies for Power Line Communications Smart Metering Network Deployment

    Directory of Open Access Journals (Sweden)

    Alberto Sendin

    2014-04-01

    Full Text Available Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS existing in the grid, covering the Low Voltage (LV segment with the lowest possible costs. Power Line Communications (PLC have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility, and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.

  2. Coupling an induction motor type generator to ac power lines. [making windmill generators compatible with public power lines

    Science.gov (United States)

    Nola, F. J. (Inventor)

    1984-01-01

    A system for coupling an induction motor type generator to an A.C. power line includes an electronic switch means that is controlled by a control system and is regulated to turn on at a relatively late point in each half cycle of its operation. The energizing power supplied by the line to the induction motor type generator is decreased and the net power delivered to the line is increased.

  3. Low-frequency electric and magnetic fields evaluation of power lines

    Energy Technology Data Exchange (ETDEWEB)

    Jenke, B.; Catania, P.J. [Univ. of Regina, Saskatchewan (Canada); Brown, D. [Government of Saskatchewan, Regina, Saskatchewan (Canada)

    1995-07-01

    This article reports the outcome of a study commissioned by the Radiation Safety Unit, Government of Saskatchewan, which addressed the public concern on exposure to low-frequency electromagnetic fields (EMFs) surrounding power lines. Measurements of EMF are reported for 14.4 to 230 kV power lines utilizing a model HI-3600-02 extreme low frequency (ELF) power frequency EMF survey meter. Field intensities were within the Canadian standards, with the recorded value for a 230 kV/230 kV line voltage yielding a maximum electric field of 1,790 V/m at 15 feet from the center and a maximum magnetic field intensity of 2,376 mA/m at 25 feet from the center. Continued research and analysis are required in determining the mechanism of interaction between EMFs and the human body and to determine if there exists a correlation between EMF exposure and health.

  4. THE NO SINUSOIDAL VOLTAGES UNDER THE SINUSOIDAL CURRENT AT THE ENTRY OF THE OPEN–ENDED LINE WITH REAL LOSS

    Directory of Open Access Journals (Sweden)

    Patsiuk V.I.

    2008-12-01

    Full Text Available he classical problems of the theoretical electrical engineering, such as open-ended (or short-circuited line energization on alternating voltage (or current, are solved by means of Fourier series method. The conditions of creation of no sinusoidal steady-state regimes in the lines with nonzero loss are discovered.

  5. An Efficient Approach for Fast and Accurate Voltage Stability Margin Computation in Large Power Grids

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2016-11-01

    Full Text Available This paper proposes an efficient approach for the computation of voltage stability margin (VSM in a large-scale power grid. The objective is to accurately and rapidly determine the load power margin which corresponds to voltage collapse phenomena. The proposed approach is based on the impedance match-based technique and the model-based technique. It combines the Thevenin equivalent (TE network method with cubic spline extrapolation technique and the continuation technique to achieve fast and accurate VSM computation for a bulk power grid. Moreover, the generator Q limits are taken into account for practical applications. Extensive case studies carried out on Institute of Electrical and Electronics Engineers (IEEE benchmark systems and the Taiwan Power Company (Taipower, Taipei, Taiwan system are used to demonstrate the effectiveness of the proposed approach.

  6. New Application’s Approach to Unified Power Quality Conditioners for Mitigation of Surge Voltages

    Directory of Open Access Journals (Sweden)

    Yeison Alberto Garcés Gomez

    2016-01-01

    Full Text Available This paper outlines a new approach for the compensation of power systems presented through the use of a unified power quality conditioner (UPQC which compensates impulsive and oscillatory electromagnetic transients. The newly proposed control technique involves a dual analysis of the UPQC where the parallel compensator is modelled as a sinusoidal controlled voltage source, while the series compensator is modelled as a sinusoidal controlled current source, opposed to the traditional approach where the parallel and series compensators are modelled as current and voltage nonsinusoidal sources, respectively. Also a new compensation algorithm is proposed through the application of the theory of generalized reactive power; this is then compared with the theory of active and reactive instantaneous power, or pq theory. The results are presented by means of simulations in MATLAB-Simulink®.

  7. DC Voltage Droop Control Implementation in the AC/DC Power Flow Algorithm: Combinational Approach

    DEFF Research Database (Denmark)

    Akhter, F.; Macpherson, D.E.; Harrison, G.P.

    2015-01-01

    In this paper, a combinational AC/DC power flow approach is proposed for the solution of the combined AC/DC network. The unified power flow approach is extended to include DC voltage droop control. In the VSC based MTDC grids, DC droop control is regarded as more advantageous in terms...... of operational flexibility, as more than one VSC station controls the DC link voltage of the MTDC system. This model enables the study of the effects of DC droop control on the power flows of the combined AC/DC system for steady state studies after VSC station outages or transient conditions without needing...... to use its complete dynamic model. Further, the proposed approach can be extended to include multiple AC and DC grids for combined AC/DC power flow analysis. The algorithm is implemented by modifying the MATPOWER based MATACDC program and the results shows that the algorithm works efficiently....

  8. Methods for determining optical power, for power-normalizing laser measurements, and for stabilizing power of lasers via compliance voltage sensing

    Science.gov (United States)

    Taubman, Matthew S; Phillips, Mark C

    2015-04-07

    A method is disclosed for power normalization of spectroscopic signatures obtained from laser based chemical sensors that employs the compliance voltage across a quantum cascade laser device within an external cavity laser. The method obviates the need for a dedicated optical detector used specifically for power normalization purposes. A method is also disclosed that employs the compliance voltage developed across the laser device within an external cavity semiconductor laser to power-stabilize the laser mode of the semiconductor laser by adjusting drive current to the laser such that the output optical power from the external cavity semiconductor laser remains constant.

  9. Low-power low-voltage chopped transconductance amplifier for noise and offset reduction

    NARCIS (Netherlands)

    Sanduleanu, M.A.T.; Nauta, Bram; Wallinga, Hans

    1997-01-01

    This paper describes the principle and design of a CMOS low-power, low-voltage, chopped transconductance amplifier, for noise and offset reduction in mixed analogue digital applications. The operation is based on chopping and dynamic element matching, to reduce noise and offset, without excessive

  10. Charge-sharing SAR ADCs for low-voltage low-power applications

    CERN Document Server

    Rabuske, Taimur

    2017-01-01

    This book introduces readers to the potential of charge-sharing (CS) successive approximation register (SAR) analog-to-digital converters (ADCs), while providing extensive analysis of the factors that limit the performance of the CS topology. The authors present guidelines and useful techniques for mitigating the limitations of the architecture, while focusing on the implementation under restricted power budgets and voltage supplies.

  11. Large Scale Solar Power Integration in Distribution Grids : PV Modelling, Voltage Support and Aggregation Studies

    NARCIS (Netherlands)

    Samadi, A.

    2014-01-01

    Long term supporting schemes for photovoltaic (PV) system installation have led to accommodating large numbers of PV systems within load pockets in distribution grids. High penetrations of PV systems can cause new technical challenges, such as voltage rise due to reverse power flow during light load

  12. High-Voltage class-D power amplifiers: design and optimization

    NARCIS (Netherlands)

    Ma, H.

    2015-01-01

    ABSTRACT Nowadays transducers are ubiquitous as interfaces between the increasingly digital world and the real physical world. The same holds for the power amplifiers driving them. This thesis focuses on the design and optimization of high-voltage class-D amplifiers, which are used for driving

  13. Tertiary control of voltage unbalance compensation for optimal power quality in islanded microgrids

    DEFF Research Database (Denmark)

    Meng, Lexuan; Tang, Fen; Savaghebi, Mehdi

    2016-01-01

    DG considering the voltage unbalance limits in local buses and DG terminals. This method realizes multi-power-quality-level control in a multi-bus islanded system by optimally utilizing DGs as distributed compensators and saves the investment for additional compensation equipment. Hardware...

  14. Series operation of power MOSFETs for high-speed, high-voltage switching applications

    Science.gov (United States)

    Baker, R. J.; Johnson, B. P.

    1993-06-01

    Series operation of power metal-oxide semiconductor field-effect transistors (MOSFETs) to increase their effective hold off voltage is described. The design procedure presented is a modification of a recently reported [Baker and Johnson, Rev. Sci. Instrum. 63, 5799 (1992)] method. Comments are made on implementing MOSFET stacks in various types of instrumentation.

  15. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    Energy Technology Data Exchange (ETDEWEB)

    Ljusev, P.; Andersen, Michael A.E.

    2005-07-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify design, increase efficiency and integration level, reduce product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented. (au)

  16. Recommendation on the Environmental Effect Report for the high-voltage transmission line between Netherlands and Norway; Advies over het Milieu-Effectrapport Hoogspanningsverbinding Noorwegen-Nederland

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-23

    The recommendation on the title subject was addressed to the Dutch Minister of Economic Affairs and concerns the environmental impact of the new high-voltage transmission line (NorNed cable) from Norway to the Eemshaven in Groningen, Netherlands. In planning this power cable the environmental impact on the Wadden Sea has to be taken into account. Therefore an environmental effect report (MER, abbreviated in Dutch) has been drafted by the Dutch cooperative of electric power generating companies, Sep, and commented by the WaddenAdviesRaad

  17. Conventional P-ω/Q-V Droop Control in Highly Resistive Line of Low-Voltage Converter-Based AC Microgrid

    Directory of Open Access Journals (Sweden)

    Xiaochao Hou

    2016-11-01

    Full Text Available In low-voltage converter-based alternating current (AC microgrids with resistive distribution lines, the P-V droop with Q-f boost (VPD/FQB is the most common method for load sharing. However, it cannot achieve the active power sharing proportionally. To overcome this drawback, the conventional P-ω/Q-V droop control is adopted in the low-voltage AC microgrid. As a result, the active power sharing among the distributed generators (DGs is easily obtained without communication. More importantly, this study clears up the previous misunderstanding that conventional P-ω/Q-V droop control is only applicable to microgrids with highly inductive lines, and lays a foundation for the application of conventional droop control under different line impedances. Moreover, in order to guarantee the accurate reactive power sharing, a guide for designing Q-V droop gains is given, and virtual resistance is adopted to shape the desired output impedance. Finally, the effects of power sharing and transient response are verified through simulations and experiments in converter-based AC Microgrid.

  18. Optimizing real power loss and voltage stability limit of a large transmission network using firefly algorithm

    Directory of Open Access Journals (Sweden)

    P. Balachennaiah

    2016-06-01

    Full Text Available This paper proposes a Firefly algorithm based technique to optimize the control variables for simultaneous optimization of real power loss and voltage stability limit of the transmission system. Mathematically, this issue can be formulated as nonlinear equality and inequality constrained optimization problem with an objective function integrating both real power loss and voltage stability limit. Transformers taps, unified power flow controller and its parameters have been included as control variables in the problem formulation. The effectiveness of the proposed algorithm has been tested on New England 39-bus system. Simulation results obtained with the proposed algorithm are compared with the real coded genetic algorithm for single objective of real power loss minimization and multi-objective of real power loss minimization and voltage stability limit maximization. Also, a classical optimization method known as interior point successive linear programming technique is considered here to compare the results of firefly algorithm for single objective of real power loss minimization. Simulation results confirm the potentiality of the proposed algorithm in solving optimization problems.

  19. High-Voltage Power Supply With Fast Rise and Fall Times

    Science.gov (United States)

    Bearden, Douglas B.; Acker, Richard M.; Kapuslka, Robert E.

    2007-01-01

    A special-purpose high-voltage power supply can be electronically switched on and off with fast rise and fall times, respectively. The output potential is programmable from 20 to 1,250 V. An output current of 50 A can be sustained at 1,250 V. The power supply was designed specifically for electronically shuttering a microchannel plate in an x-ray detector that must operate with exposure times as short as 1 ms. The basic design of the power supply is also adaptable to other applications in which there are requirements for rapid slewing of high voltages. The power-supply circuitry (see figure) includes a preregulator, which is used to program the output at 1/30 of the desired output potential. After the desired voltage has been set, the outputs of a pulse width modulator (PWM) are enabled and used to amplify the preregulator output potential by 30. The amplification is achieved by use of two voltage doublers with a transformer that has two primary and two secondary windings. A resistor is used to limit the current by controlling the drive voltage of two field-effect transistors (FETs) during turn-on of the PWM. A pulse transformer is used to turn on four FETs to short-circuit four output capacitors when the outputs of the PWM have been disabled. The most notable aspects of the performance of the power supply are a rise time of only 80 s and a fall time of only 60 s at a load current of 50 A or less. Another notable aspect is that the application of a 0-to-5-V square wave to a shutdown pin of the PWM causes the production of a 0-to-1,250-V square wave at the output terminals.

  20. Control of grid integrated voltage source converters under unbalanced conditions: development of an on-line frequency-adaptive virtual flux-based approach

    Energy Technology Data Exchange (ETDEWEB)

    Suul, Jon Are

    2012-03-15

    Three-Phase Voltage Source Converters (VSCs) are finding widespread applications in grid integrated power conversion systems. The control systems of such VSCs are in an increasing number of these applications required to operate during voltage disturbances and unbalanced conditions. Control systems designed for grid side voltagesensor-less operation are at the same time becoming attractive due to the continuous drive for cost reduction and increased reliability of VSCs, but are not commonly applied for operation during unbalanced conditions. Methods for voltage-sensor-less grid synchronization and control of VSCs under unbalanced grid voltage conditions will therefore be the main focus of this Thesis. Estimation methods based on the concept of Virtual Flux, considering the integral of the converter voltage in analogy to the flux of an electric machine, are among the simplest and most well known techniques for achieving voltage-sensor-less grid synchronization. Most of the established techniques for Virtual Flux estimation are, however, either sensitive to grid frequency variations or they are not easily adaptable for operation under unbalanced grid voltage conditions. This Thesis addresses both these issues by proposing a simple approach for Virtual Flux estimation by utilizing a frequency-adaptive filter based on a Second Order Generalized Integrator (SOGI). The proposed approach can be used to achieve on-line frequency-adaptive varieties of conventional strategies for Virtual Flux estimation. The main advantage is, however, that the SOGI-based Virtual Flux estimation can be arranged in a structure that achieves inherent symmetrical component sequence separation under unbalanced conditions. The proposed method for Virtual Flux estimation can be used as a general basis for voltage-sensor-less grid synchronization and control during unbalanced conditions. In this Thesis, the estimated Virtual Flux signals are used to develop a flexible strategy for control of active

  1. 3D Power Line Extraction from Multiple Aerial Images

    Directory of Open Access Journals (Sweden)

    Jaehong Oh

    2017-09-01

    Full Text Available Power lines are cables that carry electrical power from a power plant to an electrical substation. They must be connected between the tower structures in such a way that ensures minimum tension and sufficient clearance from the ground. Power lines can stretch and sag with the changing weather, eventually exceeding the planned tolerances. The excessive sags can then cause serious accidents, while hindering the durability of the power lines. We used photogrammetric techniques with a low-cost drone to achieve efficient 3D mapping of power lines that are often difficult to approach. Unlike the conventional image-to-object space approach, we used the object-to-image space approach using cubic grid points. We processed four strips of aerial images to automatically extract the power line points in the object space. Experimental results showed that the approach could successfully extract the positions of the power line points for power line generation and sag measurement with the elevation accuracy of a few centimeters.

  2. Negative Reactance Impacts on the Eigenvalues of the Jacobian Matrix in Power Flow and Type-1 Low-Voltage Power-Flow Solutions

    DEFF Research Database (Denmark)

    Ding, Tao; Li, Cheng; Yang, Yongheng

    2017-01-01

    It was usually considered in power systems that power flow equations had multiple solutions and all the eigenvalues of Jacobian ma-trix at the high-voltage operable solution should have negative real parts. Accordingly, type-1 low-voltage power flow solutions are defined in the case...... solution may be positive and also the type-1 low-voltage solutions could have more than one positive real-part eigen-values, being a major challenge. Therefore, in this paper, the recognition of the type-1 low-voltage power flow solutions is re-examined with the presence of negative reactance. Selected......-voltage operable solution as well as the number of positive real-part eigenvalues at the type-1 low-voltage power flow solutions....

  3. Fretting Wear Behaviors of Aluminum Cable Steel Reinforced (ACSR Conductors in High-Voltage Transmission Line

    Directory of Open Access Journals (Sweden)

    Xingchi Ma

    2017-09-01

    Full Text Available This work reports the fretting wear behavior of aluminum cable steel reinforced (ACSR conductors for use in high-voltage transmission line. Fretting wear tests of Al wires were conducted on a servo-controlled fatigue testing machine with self-made assistant apparatus, and their fretting process characteristics, friction force, wear damage, and wear surface morphology were detailed analyzed. The results show that the running regime of Al wires changes from a gross slip regime to a mixed regime more quickly as increasing contact load. With increasing amplitudes, gross slip regimes are more dominant under contact loads of lower than 30 N. The maximum friction force is relatively smaller in the NaCl solution than in a dry friction environment. The primary wear mechanisms in dry friction environments are abrasive wear and adhesive wear whereas abrasive wear and fatigue damage are dominant in NaCl solution.

  4. 32 CFR 644.431 - Power transmission lines.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to the...

  5. Direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp

    DEFF Research Database (Denmark)

    Ljusev, Petar; Andersen, Michael Andreas E.

    2005-01-01

    This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify the design, increase effic...... efficiency, reduce the product volume and lower its cost. As an example, the principle of operation and the measurements made on a direct-conversion switching-mode audio power amplifier with active capacitive voltage clamp are presented.......This paper discusses the advantages and problems when implementing direct energy conversion switching-mode audio power amplifiers. It is shown that the total integration of the power supply and Class D audio power amplifier into one compact direct converter can simplify the design, increase...

  6. Background voltage distortion influence on power electric systems in the presence of the Steinmetz circuit

    Energy Technology Data Exchange (ETDEWEB)

    Sainz, Luis; Pedra, Joaquin [Department of Electrical Engineering, ETSEIB-UPC, Av. Diagonal 647, 08028 Barcelona (Spain); Caro, Manuel [IDOM Ingenieria y Arquitectura, C. Barcas 2, 46002 Valencia (Spain)

    2009-01-15

    In traction systems, it is usual to connect reactances in delta configuration with single-phase loads to reduce voltage unbalances and avoid electric system operation problems. This set is known as Steinmetz circuit. Parallel and series resonances can occur due to the capacitive reactance of the Steinmetz circuit and affect power quality. In this paper, the series resonance ''observed'' from the supply system is numerically located. The study of this resonance is important to avoid problems due to background voltage distortion. Experimental measurements are also presented to validate the obtained numerical results. (author)

  7. Very high voltage power supply system for the ring imaging Cherenkov detectors of the LHCb experiment

    CERN Document Server

    Fontanellia, F; Gracco, V; Gys, T; Jost, B; Minì, G; Neufeld, N; Petrolini, A; Piedigrossi, D; Sannino, M

    2009-01-01

    A modular power supply system is described, for use in the Ring Imaging Cherenkov Detectors of the LHCb experiment. The main characteristics of the supply are very good time stability and voltage resolution, full programmability, floating supplies, self protection and remote control. The choice of a commercial HV module with standard control inputs allows easy customisation to adapt our design to different requirements. The realisation shown here supplies voltages up to 20 kV with a maximum current of 0.5 mA and up to 32 channels on a single crate.

  8. Active power filter for medium voltage networks with predictive current control

    Energy Technology Data Exchange (ETDEWEB)

    Verne, Santiago A.; Valla, Maria I. [Laboratorio de Electronica Industrial, Control e Instrumentacion (LEICI), Facultad de Ingenieria, Universidad Nacional de La Plata and CONICET, La Plata (Argentina)

    2010-12-15

    A transformer less Shunt Active Power Filter (SAPF) for medium voltage distribution networks based on Multilevel Diode Clamped Inverter is presented in this paper. Converter current control is based on a Model Predictive strategy, which gives very fast current response. Also, the algorithm includes voltage balancing capability which is essential for proper converter operation. The presented current control algorithm is naturally applicable to converters with an arbitrary number of levels with reduced computational effort by virtue of the incorporation of switching restrictions which are necessary for reliable converter operation. The performance of the proposed algorithm is evaluated by means of computer simulations. (author)

  9. Voltage-Mode Multifunction Biquadratic Filters Using New Ultra-Low-Power Differential Difference Current Conveyors

    Directory of Open Access Journals (Sweden)

    M. Kumngern

    2013-06-01

    Full Text Available This paper presents two low-power voltage-mode multifunction biquadratic filters using differential difference current conveyors. Each proposed circuit employs three differential difference current conveyors, two grounded capacitors and two grounded resistors. The low-voltage ultra-low-power differential difference current conveyor is used to provide low-power consumption of the proposed filters. By appropriately connecting the input and output terminals, the proposed filters can provide low-pass, band-pass, high-pass, band-stop and all-pass voltage responses at high-input terminals, which is a desirable feature for voltage-mode operations. The natural frequency and the quality factor can be orthogonally set by adjusting the circuit components. For realizing all the filter responses, no inverting-type input signal requirements as well as no component-matching conditional requirements are imposed. The incremental parameter sensitivities are also low. The characteristics of the proposed circuits are simulated by using PSPICE simulators to confirm the presented theory.

  10. A monolithic integrated low-voltage deep brain stimulator with wireless power and data transmission

    Science.gov (United States)

    Zhang, Zhang; Ye, Tan; Jianmin, Zeng; Xu, Han; Xin, Cheng; Guangjun, Xie

    2016-09-01

    A monolithic integrated low-voltage deep brain stimulator with wireless power and data transmission is presented. Data and power are transmitted to the stimulator by mutual inductance coupling, while the in-vitro controller encodes the stimulation parameters. The stimulator integrates the digital control module and can generate the bipolar current with equal amplitude in four channels. In order to reduce power consumption, a novel controlled threshold voltage cancellation rectifier is proposed in this paper to provide the supply voltage of the stimulator. The monolithic stimulator was fabricated in a SMIC 0.18 μm 1-poly 6-metal mixed-signal CMOS process, occupying 0.23 mm2, and consumes 180 μW on average. Compared with previously published stimulators, this design has advantages of large stimulated current (0-0.8 mA) with the double low-voltage supply (1.8 and 3.3 V), and high-level integration. Project supported by the National Natural Science Foundation of China (Nos. 61404043, 61401137), the Key Laboratory of Infrared Imaging Materials and Detectors, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (Nos. IIMDKFJJ-13-06, IIMDKFJJ-14-03), and the Fundamental Research Funds for the Central Universities (No. 2015HGZX0026).

  11. Design of High-Voltage Switch-Mode Power Amplifier Based on Digital-Controlled Hybrid Multilevel Converter

    National Research Council Canada - National Science Library

    Hou, Yanbin; Sun, Wanrong; Ren, Aifeng; Liu, Shuming

    2016-01-01

    ...) and hybrid multilevel converter. Under the control of input signal, cascaded power converters with separate DC sources operate in PSM switch mode to directly generate high-voltage and high-power output...

  12. High Input Voltage Discharge Supply for High Power Hall Thrusters Using Silicon Carbide Devices

    Science.gov (United States)

    Pinero, Luis R.; Scheidegger, Robert J.; Aulsio, Michael V.; Birchenough, Arthur G.

    2014-01-01

    A power processing unit for a 15 kW Hall thruster is under development at NASA Glenn Research Center. The unit produces up to 400 VDC with two parallel 7.5 kW discharge modules that operate from a 300 VDC nominal input voltage. Silicon carbide MOSFETs and diodes were used in this design because they were the best choice to handle the high voltage stress while delivering high efficiency and low specific mass. Efficiencies in excess of 97 percent were demonstrated during integration testing with the NASA-300M 20 kW Hall thruster. Electromagnet, cathode keeper, and heater supplies were also developed and will be integrated with the discharge supply into a vacuum-rated brassboard power processing unit with full flight functionality. This design could be evolved into a flight unit for future missions that requires high power electric propulsion.

  13. Coordinated Control Strategies of VSC-HVDC-Based Wind Power Systems for Low Voltage Ride Through

    Directory of Open Access Journals (Sweden)

    Xinyin Zhang

    2015-07-01

    Full Text Available The Voltage Source Converter-HVDC (VSC-HVDC system applied to wind power generation can solve large scale wind farm grid-connection and long distance transmission problems. However, the low voltage ride through (LVRT of the VSC-HVDC connected wind farm is a key technology issue that must be solved, and it is currently lacking an economic and effective solution. In this paper, a LVRT coordinated control strategy is proposed for the VSC-HVDC-based wind power system. In this strategy, the operation and control of VSC-HVDC and wind farm during the grid fault period is improved. The VSC-HVDC system not only provides reactive power support to the grid, but also effectively maintains the power balance and DC voltage stability by reducing wind-farm power output, without increasing the equipment investment. Correspondingly, to eliminate the influence on permanent magnet synchronous generator (PMSG-based wind turbine (WT systems, a hierarchical control strategy is designed. The speed and validity of the proposed LVRT coordinated control strategy and hierarchical control strategy were verified by MATLAB/Simulink simulations.

  14. Active Power and DC-link Voltage Coordinative Control for Cascaded DC-AC Converter with Bidirectional Power Application

    DEFF Research Database (Denmark)

    Tian, Yanjun; Chen, Zhe; Deng, Fujin

    2015-01-01

    Two stage cascaded converters are widely used in DC/AC hybrid systems to achieve the bidirectional power transmission. The topology of dual active bridge cascaded with inverter (DABCI) is commonly used in this application. This paper proposes a coordinative control method for DABCI and it’s able......, and this responsibility sharing control can effectively suppress the impact of the power variation on the DC-link voltage, without sacrificing stability. The proposed control method is also effective for DABCI in unidirectional power transmission. The effectiveness of the propose control has been validated by both...

  15. 30 CFR 77.906 - Trailing cables supplying power to low-voltage mobile equipment; ground wires and ground check...

    Science.gov (United States)

    2010-07-01

    ... portable or mobile equipment from low-voltage three-phase resistance grounded power systems shall contain... Alternating Current Circuits § 77.906 Trailing cables supplying power to low-voltage mobile equipment; ground... conductor. Such trailing cables shall include an insulated conductor for the ground continuity check circuit...

  16. Low-Voltage Ride-Through Operation of Power Converters in Grid-Interactive Microgrids by Using Negative-Sequence Droop Control

    DEFF Research Database (Denmark)

    Zhao, Xin; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    Due to the increasing penetration level of microgrids (MGs), it becomes a critical issue for MGs to help sustaining power system stability. Therefore, ancillary services, such as the low-voltage ride-through (LVRT) capability should be incorporated in MGs in order to guarantee stable operation of......, while the secondary controller is based on a positive/negative sequence droop scheme which is able to coordinate the power injection during voltage sags. Experimental results are obtained to verify the effectiveness of the proposed control strategy....... of the utility grid during grid faults. In this paper, a LVRT control strategy based on positive/negative sequence droop control is proposed for grid-interactive MGs to ride-through voltage sags with not only inductive/resistive, but also complex line impedance. By using the proposed control strategy, MGs can...

  17. Control of single-phase islanded PV/battery minigrids based on power-line signaling

    DEFF Research Database (Denmark)

    Quintana, Pablo; Guerrero, Josep M.; Dragicevic, Tomislav

    2014-01-01

    types of renewable energy sources (RES) and energy storage systems (ESS). Specifically, the recharging process of secondary battery, the most prominent ESS, should be done in a specific manner to preserve its life-time, microgrid line voltage must be kept within the bounds and the energy offered by RES......Power regulation of all converter units in a micro-grid should not be only determined by load demand, but also by the available power of each unit, i.e. a converter fed by a battery. Energy management control is essential in order to handle the variety of prime movers which may include different...

  18. Possibility of using porcelain samples of high-voltage line insulators for radiation dose reconstruction by EPR spectroscopy.

    Science.gov (United States)

    Khamidova, L G; Ivannikov, A I; Kondrashov, A E; Tikounov, D D; Skvortsov, V G; Stepanenko, V F; Hoshi, M

    2001-12-01

    In electron paramagnetic resonance spectra of irradiated porcelain samples from high-voltage supply line insulators three overlapping single signals were observed. The dependencies of the amplitude of these signals on the microwave power, irradiation dose and the stability in darkness and in natural light were investigated. It was concluded that for dosimetric purposes it is reasonable to use the radiation-induced signal with g = 2.001, which could be ascribed to the E' centres of quartz. The microwave power dependence of the amplitude of this signal is saturated at 1 mW, the dose dependence is saturated at about 60 mGy. A minimal level of dose determination is about 1 Gy, and it is limited mainly by the accuracy of subtraction of the background signal existing in the unirradiated sample. The radiation-induced signal is stable in the darkness, but rapidly faded in natural light, therefore, for dosimetric purposes it is possible to use only insulators covered with dark glaze or ceramic samples from the very interior of the insulators.

  19. Submicrosecond linear pulse transformer for 800 kV voltage with modular low-inductance primary power supply

    Energy Technology Data Exchange (ETDEWEB)

    Bykov, Yu. A.; Krastelev, E. G., E-mail: ekrastelev@yandex.ru; Popov, G. V.; Sedin, A. A.; Feduschak, V. F. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2016-12-15

    A pulsed power source with voltage amplitude up to 800 kV for fast charging (350–400 ns) of the forming line of a high-current nanosecond accelerator is developed. The source includes capacitive energy storage and a linear pulse transformer. The linear transformer consists of a set of 20 inductors with circular ferromagnetic cores surrounded by primary windings inside of which a common stock adder of voltage with film-glycerol insulation is placed. The primary energy storage consists of ten modules, each of which is a low-inductance assembly of two capacitors with a capacitance of 0.35 μF and one gas switch mounted in the same frame. The total energy stored in capacitors is 5.5 kJ at the operating voltage of 40 kV. According to test results, the parameters of the equivalent circuit of the source are the following: shock capacitance = 17.5 nF, inductance = 2 μH, resistance = 3.2 Ω.

  20. Power quality issues into a Danish low-voltage grid with electric vehicles

    DEFF Research Database (Denmark)

    Marra, Francesco; Jensen, Morten M.; Garcia-Valle, Rodrigo

    2011-01-01

    An increased interest on electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs) is dealing with their introduction into low voltage (LV) distribution grids. Lately, analysis on power quality issues has received attention when considering EVs as additional load. The charging of EVs...... is expected without a centralized coordination in the first years, therefore a study on voltage variations and loading of LV grids is needed to estimate the immediate impact by EVs. In this work, the modeling and simulation of a Danish residential LV grid is conducted considering the two scenarios of dumb...... charging and overnight charging. The effect of different shares of EVs on voltage variations and transformer loading is assessed and analyzed. Results have shown that if single-phase, 16 A charging is employed, the actual LV grid would withstand the contingency of up to 30-40% of EVs charging overnight....

  1. Interconnected High-Voltage Pulsed-Power Converters System Design for H− Ion Sources

    CERN Document Server

    Aguglia, D

    2014-01-01

    This paper presents the design and experimental validations of a system of three new high-voltage (HV) pulsedpower converters for the H− sources. The system requires three pulsed voltages (50, 40, and 25 kV to ground) at 2-Hz repetition rate, for 700 μs of usable flat-top. The solution presents ripplefree output voltages and minimal stored energy to protect the ion source from the consequences of arc events. Experimental results on the final full-scale prototype are presented. In case of short-circuit events, the maximal energy delivered to the source is in the Joule range. HV flat-top stability of 1% is experimentally achieved with a simple Proportional-Integral- Derivative regulation and preliminary tuned H− source (e.g., radio frequency control, gas injection, and so forth). The system is running since more than a year with no power converter failures and damage to the source.

  2. Solid-Body Fuse Developed for High- Voltage Space Power Missions

    Science.gov (United States)

    Dolce, James L.; Baez, Anastacio N.

    2001-01-01

    AEM Incorporated has completed the development, under a NASA Glenn Research Center contract, of a solid-body fuse for high-voltage power systems of satellites and spacecraft systems. High-reliability fuses presently defined by MIL-PRF-23419 do not meet the increased voltage and amperage requirements for the next generation of spacecraft. Solid-body fuses exhibit electrical and mechanical attributes that enable these fuses to perform reliably in the vacuum and high-vibration and -shock environments typically present in spacecraft applications. The construction and screening techniques for solid-body fuses described by MIL-PRF-23419/12 offer an excellent roadmap for the development of high-voltage solid-body fuses.

  3. Investigations in the modelling and control of a medium voltage hybrid inverter system that uses a low voltage /low power rated auxiliary current source inverter

    OpenAIRE

    Papadopoulos, Savvas; Rashed, Mohamed; Klumpner, Christian; Wheeler, Patrick

    2016-01-01

    Hybrid converters consist of a main inverter processing the bulk of the power with poor waveform performance and a fast and versatile auxiliary inverter to correct the distortion. In this paper, the main converter is a medium voltage NPC inverter and the auxiliary inverter is a low-voltage and low-current rated current source inverter (CSI), with series capacitor being used to minimize the CSI voltage stress. The result is a high output current quality which is obtained with a very low switch...

  4. Low-Power, Low-Voltage Analog to Digital ΣΔ

    DEFF Research Database (Denmark)

    Wismar, Ulrik Sørensen

    2007-01-01

    This thesis is the result of three years of research in the eld of integrated analog electronics. The research was carried out by Ulrik Wismar as part of the work leading to the PhD title. It is expected that the reader is familiar with basic semiconductor theory. The topic of this work is various......, and since long operation time is required, low supply voltage and low power consumption are of paramount importance. Consequently, various topologies have been compared to nd the most power ecient audio frequency modulator topology. Chapter 4 of this thesis compares power consumption of two of the most...

  5. Control strategy and hardware implementation for DC–DC boost power circuit based on proportional–integral compensator for high voltage application

    Directory of Open Access Journals (Sweden)

    Sanjeevikumar Padmanaban

    2015-06-01

    Full Text Available For high-voltage (HV applications, the designers mostly prefer the classical DC–DC boost converter. However, it lacks due to the limitation of the output voltage by the gain transfer ratio, decreased efficiency and its requirement of two sensors for feedback signals, which creates complex control scheme with increased overall cost. Furthermore, the output voltage and efficiency are reduced due to the self-parasitic behavior of power circuit components. To overcome these drawbacks, this manuscript provides, the theoretical development and hardware implementation of DC–DC step-up (boost power converter circuit for obtaining extra output-voltage high-performance. The proposed circuit substantially improves the high output-voltage by voltage-lift technology with a closed loop proportional–integral controller. This complete numerical model of the converter circuit including closed loop P-I controller is developed in simulation (Matlab/Simulink software and the hardware prototype model is implemented with digital signal processor (DSP TMS320F2812. A detailed performance analysis was carried out under both line and load regulation conditions. Numerical simulation and its verification results provided in this paper, prove the good agreement of the circuit with theoretical background.

  6. To Solution of Classical Problem Pertaining to Magnetic Interference of Overhead Power Transmission Line on Extended Conducting Communications

    Directory of Open Access Journals (Sweden)

    V. Glushko

    2013-01-01

    Full Text Available The paper considers a problem pertaining to magnetic interference of overhead power transmission lines and high-voltage bus bars of electrical installations on extended conducting communications and secondary circuits of relay protection and automation. A simplified task solution has been obtained on the basis of the Carson integral approximation.

  7. Variation of Tower Footing Resistance on the Lightning Surge Propagation through Overhead Power Distribution Lines

    Directory of Open Access Journals (Sweden)

    MARIUT, E. L.

    2016-02-01

    Full Text Available This paper deals with the analysis of the effects of electromagnetic transients generated by lightning on power distribution lines, considering the influence of tower footing resistance variation. Both types of lightning stroke, direct and induced, are considered. The model of a 20 kV three-phase overhead power distribution line is performed considering a simple line circuit with triangle canopy and 50/8 mm2 Ol-Al conductors. The model of the power distribution line is done considering a Multistory tower model. New concepts regarding lightning assessment through Electromagnetic Transients program and Finite Element Method are implemented. The simulations are performed based on a time domain analysis, considering the lightning stroke as an electromagnetic perturbation within frequency range of 10-100 kHz. A contribution to value creation is the design of the Multistory tower model, used for electromagnetic transients analysis for medium voltage power distribution lines. Excepting previous research, current study was done by considering the variation of tower footing resistance of the tower, between 4-35 ohms. The novelty of the study is the analysis of the dependency determined by the variation of tower footing resistance on the lightning surge propagation through power distribution networks and subsequent consumers.

  8. A Measurement and Power Line Communication System Design for Renewable Smart Grids

    Science.gov (United States)

    Kabalci, E.; Kabalci, Y.

    2013-10-01

    The data communication over the electric power lines can be managed easily and economically since the grid connections are already spread around all over the world. This paper investigates the applicability of Power Line Communication (PLC) in an energy generation system that is based on photovoltaic (PV) panels with the modeling study in Matlab/Simulink. The Simulink model covers the designed PV panels, boost converter with Perturb and Observe (P&O) control algorithm, full bridge inverter, and the binary phase shift keying (BPSK) modem that is utilized to transfer the measured data over the power lines. This study proposes a novel method to use the electrical power lines not only for carrying the line voltage but also to transmit the measurements of the renewable energy generation plants. Hence, it is aimed at minimizing the additional monitoring costs such as SCADA, Ethernet-based or GSM based systems by using the proposed technique. Although this study is performed with solar power plants, the proposed model can be applied to other renewable generation systems. Consequently, the usage of the proposed technique instead of SCADA or Ethernet-based systems eliminates additional monitoring costs.

  9. Modularized Three-Phase Semiconductor Transformer with Bidirectional Power Flow for Medium Voltage Application

    Directory of Open Access Journals (Sweden)

    Do-Hyun Kim

    2016-08-01

    Full Text Available This paper describes a prototype of modularized three-phase semiconductor transformer that was developed in the lab for feasibility study. The developed prototype is composed of three units of single-phase semiconductor transformer coupled in Y-connection. Each single-phase unit has multiple units of high-voltage high-frequency resonant AC–DC converter, a low-voltage hybrid-switching DC–DC converter, and a low-voltage hybrid-switching DC–AC inverter. Also, each single-phase unit has two digital signal processor (DSP boards to control converter operation and to acquire monitoring data. The monitoring system was developed based on LabView by using controller area network (CAN communication between the DSP board and the personal computer (PC. Through diverse experimental analyses it was verified that the prototype operates with proper performance under normal and sag conditions. The developed prototype confirms the possibility of fabricating a commercial high-voltage high-power semiconductor transformer by increasing the number of series-connected converter modules in high-voltage side and improving the system efficiency with a new switching device such as an SiC device.

  10. Investigations of the quality of hospital electric power supply and the tolerance of medical electric devices to voltage dips.

    Science.gov (United States)

    Hanada, Eisuke; Itoga, Shuuya; Takano, Kyoko; Kudou, Takato

    2007-06-01

    Medical devices driven by electric power have come to be commonly used in hospitals, and rapid changes of voltage or current can easily cause them to fail. A stable and high quality power supply is indispensable in order to maintain safety in the modern clinical setting. Therefore, we investigated the quality of the power supply in a hospital and determined the tolerance of 13 pieces of medical equipment to voltage dips. The results showed little distortion of the voltage wave. However, we found an approximately 7% momentary voltage dip caused by lightening and other problems, such as 2 to 5% periodic drops in voltage and voltage wave distortions caused by incorrect grounding. In a tolerance test, the settings of some medical devices were changed at the time of automatic reboot after a disturbance. For another device, trend information was initialized.

  11. A Study on the Practical Grounding System in Power Distribution Lines

    Science.gov (United States)

    Miyazaki, Teru; Okabe, Shigemitsu; Aiba, Kiyoshi; Hirai, Takao; Yoshinaga, Jun

    It is important for electric power companies to maintain grounding resistances adequately for the safety of the public. But they have difficulty in managing those grounding systems because vast amounts of grounding electrodes are installed in distribution lines. Based on the statistical data of surge currents through lightning arrestors and electrical surges in customers, a rated value of the grounding resistance for lightning arrestors on distribution lines was specified in the 1960's. TEPCO had conducted field research to measure the waveforms of surge voltage and current in order to rationalize the lightning protection design of distribution lines. And the authors proposed a lightning-surges analysis model based on the observation data. In this study, a lightning surge analysis for the rationalization of the grounding system was carried out by means of the EMTP. The calculated results suggest that a practical grounding design is possible. That can be useful for the Electric Power Companies to manage grounding systems.

  12. Extraction of power lines from mobile laser scanning data

    Science.gov (United States)

    Xiang, Qing; Li, Jonathan; Wen, Chenglu; Huang, Pengdi

    2016-03-01

    Modern urban life is becoming increasingly more dependent on reliable electric power supply. Since power outages cause substantial financial losses to producers, distributors and consumers of electric power, it is in the common interest to minimize failures of power lines. In order to detect defects as early as possible and to plan efficiently the maintenance activities, distribution networks are regularly inspected. Carrying out foot patrols or climbing the structures to visually inspect transmission lines and aerial surveys (e.g., digital imaging or most recent airborne laser scanning (ALS) are the two most commonly used methods of power line inspection. Although much faster in comparison to the foot patrol inspection, aerial inspection is more expensive and usually less accurate, in complex urban areas particularly. This paper presents a scientific work that is done in the use of mobile laser scanning (MLS) point clouds for automated extraction of power lines. In the proposed method, 2D power lines are extracted using Hough transform in the projected XOY plane and the 3D power line points are visualized after the point searching. Filtering based on an elevation threshold is applied, which is combined with the vehicle's trajectory in the horizontal section.

  13. Noise Sources, Effects and Countermeasures in Narrowband Power-Line Communications Networks: A Practical Approach

    Directory of Open Access Journals (Sweden)

    Gregorio López

    2017-08-01

    Full Text Available The integration of Distributed Generation, Electric Vehicles, and storage without compromising the quality of the power delivery requires the deployment of a communications overlay that allows monitoring and controlling low voltage networks in almost real time. Power Line Communications are gaining momentum for this purpose since they present a great trade-off between economic and technical features. However, the power lines also represent a harsh communications medium which presents different problems such as noise, which is indeed affected by Distributed Generation, Electric Vehicles, and storage. This paper provides a comprehensive overview of the types of noise that affects Narrowband Power Line Communications, including normative noises, noises coming from common electronic devices measured in actual operational power distribution networks, and noises coming from photovoltaic inverters and electric vehicle charging spots measured in a controlled environment. The paper also reviews several techniques to mitigate the effects of noise, paying special attention to passive filtering, as for being one of the most widely used solution to avoid this kind of problems in the field. In addition, the paper presents a set of tests carried out to evaluate the impact of some representative noises on Narrowband Power Line Communications network performance, as well as the effectiveness of different passive filter configurations to mitigate such an impact. In addition, the considered sources of noise can also bring value to further improve PLC communications in the new scenarios of the Smart Grid as an input to theoretical models or simulations.

  14. Model Predictive Controlled Active NPC Inverter for Voltage Stress Balancing Among the Semiconductor Power Switches

    Science.gov (United States)

    Parvez Akter, Md.; Dah-Chuan Lu, Dylan

    2017-07-01

    This paper presents a model predictive controlled three-level three-phase active neutral-point-clamped (ANPC) inverter for distributing the voltage stress among the semiconductor power switches as well as balancing the neutral-point voltage. The model predictive control (MPC) concept uses the discrete variables and effectively operates the ANPC inverter by avoiding any linear controller or modulation techniques. A 4.0 kW three-level three-phase ANPC inverter is developed in the MATLAB/Simulink environment to verify the effectiveness of the proposed MPC scheme. The results confirm that the proposed model predictive controlled ANPC inverter equally distributes the voltage across all the semiconductor power switches and provides lowest THD (0.99%) compared with the traditional NPC inverter. Moreover, the neutral-point voltage balancing is accurately maintained by the proposed MPC algorithm. Furthermore, this MPC concept shows the robustness capability against the parameter uncertainties of the system which is also analyzed by MATLAB/Simulink.

  15. Induced Voltages Ratio-Based Algorithm for Fault Detection, and Faulted Phase and Winding Identification of a Three-Winding Power Transformer

    Directory of Open Access Journals (Sweden)

    Byung Eun Lee

    2014-09-01

    Full Text Available This paper proposes an algorithm for fault detection, faulted phase and winding identification of a three-winding power transformer based on the induced voltages in the electrical power system. The ratio of the induced voltages of the primary-secondary, primary-tertiary and secondary-tertiary windings is the same as the corresponding turns ratio during normal operating conditions, magnetic inrush, and over-excitation. It differs from the turns ratio during an internal fault. For a single phase and a three-phase power transformer with wye-connected windings, the induced voltages of each pair of windings are estimated. For a three-phase power transformer with delta-connected windings, the induced voltage differences are estimated to use the line currents, because the delta winding currents are practically unavailable. Six detectors are suggested for fault detection. An additional three detectors and a rule for faulted phase and winding identification are presented as well. The proposed algorithm can not only detect an internal fault, but also identify the faulted phase and winding of a three-winding power transformer. The various test results with Electromagnetic Transients Program (EMTP-generated data show that the proposed algorithm successfully discriminates internal faults from normal operating conditions including magnetic inrush and over-excitation. This paper concludes by implementing the algorithm into a prototype relay based on a digital signal processor.

  16. Calculation of the Electric Field and of the Parameters Of Controlled Self Compensating Power Lines 110 kV Line Using the Finite Volume Method

    Directory of Open Access Journals (Sweden)

    Patsyuk V.

    2015-12-01

    Full Text Available The paper studies the problem of calculating the electric field of the 110kV electric lines of CSCPL (Controlled Self Compensating Power Lines type. The potential of electrical conductors is determined by a system of equations for voltages taking into account there phase shift at every moment of time. set of values of the voltages in the system, taking into account the phase shift of the voltage vectors in time. We dispose the possibilities that ensure to calculate the linear values of capacity and inductance of the line knowing the electric field characteristics for a given geometry. The electric line with the horizontal placement of wires is studied. The repartition of the electric field for the limited domain of a square with sides of 100x100 m, the edges of which have zero values of potential is determined. To obtain a numerical solution of Dirichlet formulated problem we will consider the domain as a set of small triangles. As the approximate solution of the formulated problem, we will consider the piecewise-defined function , which must be continuous in the domain and of linear nature on each triangle . To calculate the electric fields when changing the phase shifting angle for voltages of conductors displaced close to each other in the 0-1800 frequency band and of different values of discretization time on the period of fundamental wave of voltage, the method of finite volumes has been used. The results of numerical calculation of the character of repartition of the potential in the field of the line for different values of time and of a phase shift of the vectors of applied voltages to the conductors of close phases for the 110 kV line of CSCPL type have been showed.

  17. AC power quality improvement for line-commutated inverters in photovoltaic applications

    Science.gov (United States)

    Pautzke, A. W.

    The optimization and testing of a line-commutated inverter (LCI) for linking photovoltaic arrays to utility ac systems are reported. A parity simulator is used to optimize both the basic LCI circuit and the prototype device at the operating parameters, ac line = 240 V ac, single phase; dc voltage = 200 V; dc current = 40 A; and firing angle = 160 deg. The design of the harmonic filter and power-factor-compensation network (using the parity simulator to determine the component values) is explained, and the waveforms obtained with the basic, improved-simulation, and improved-prototype LCIs are shown. Although a power-quality standard has not yet been established, the OEM selling price (in quantities of 1000) of a production LCI with power factor 0.88, ITHD 12 percent, and efficiency 93 percent, is estimated at 25 cents/watt, including the required isolation transformer.

  18. Monotonic transition based forward body bias for dual threshold voltage low power embedded processors

    Directory of Open Access Journals (Sweden)

    S. Jayapal

    2006-01-01

    Full Text Available Dual threshold voltage and forward body bias techniques are effective ways to optimally balance the standby leakage power and performance. In this paper, we propose a novel fine-grained forward body biasing scheme for monotonic static logic circuits. In the proposed scheme, the forward body bias is applied to high threshold voltage of either the pull-up or the pull-down network based on the evaluation transition and the state of operation. This technique improves the low skew NAND and NOR circuit performance by 7% and 11%, high skew NAND and NOR by 8% and 13% respectively. It reduces both active and standby leakage power as compared to monotonic static CMOS with dual-VT technique. The simulations are carried out using 130 nm mixed mode process technology to validate our proposed technique.

  19. Voltage and reactive power control in WPPs. Solutions adopted and lessons learned from three international experiences

    Energy Technology Data Exchange (ETDEWEB)

    Quinonez-Varela, G.; Lorenzo-Sotelo, P.; Alonso-Sadaba, O.; Arlaban-Gabeiras, M.T.; Solano-Lopez, L.; Giraut-Ruso, E.; Chocarro-Aguirrebengoa, I.; Duddy, P.; Ruiz-Guillen, J.; Rebollo-Rico, I. [Acciona Energia, S.A., Sarriguren (Spain)

    2010-07-01

    Voltage and reactive power control is a requirement imposed on wind power plants by numerous System Operators around the world in recent years. Nowadays, more stringent demands are being enforced to allow a larger and safer grid integration of wind generation. The Grid Codes defining these requirements differ from each other depending on the country, characteristics of the grid and other site specific conditions. This paper presents three relevant examples of Acciona's experience in adopting solutions to meet the latest voltage and reactive control requirements in Canada, Australia and Spain, each case based on different wind turbine technology namely Full Converter, DFIG and Squirrel Cage respectively. A thorough discussion of the solutions is provided including a description of the control algorithms and results from field tests performed to demonstrate compliance. (orig.)

  20. A Study on Gas Insulation Characteristics for Design Optimization of High Voltage Power Apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I. S.; Kim, M. K.; Seo, K. S.; Moon, I. W.; Choi, C. K. [Korea Electrotechnology Research Institute (Korea, Republic of)

    1996-12-01

    This study aim of obtaining the basic data for gas insulation in the high voltage apparatus and for investigating the breakdown characteristics in uniform field and non-uniform which the geometric construction in the practical power apparatus. In this study, the research results on the insulation technology published earlier are reviewed and the basic data for an optimum design of a high voltage apparatus are obtained thorough the experiment and computer simulation by using a uniform field. The main result are summarized as follows: (A) Investigation on the insulation technology in a large-capacity power apparatus. (B) Investigation on the breakdown characteristics in particle contaminated condition. (C) Investigation on the design in computer simulation. (D) Investigation on the simulation technology of breakdown characteristics. (E) Investigation on breakdown characteristics in the nonuniform field and experiment. (author). refs., figs., tabs.

  1. Promise and Challenges of High-Voltage SiC Bipolar Power Devices

    Directory of Open Access Journals (Sweden)

    Tsunenobu Kimoto

    2016-11-01

    Full Text Available Although various silicon carbide (SiC power devices with very high blocking voltages over 10 kV have been demonstrated, basic issues associated with the device operation are still not well understood. In this paper, the promise and limitations of high-voltage SiC bipolar devices are presented, taking account of the injection-level dependence of carrier lifetimes. It is shown that the major limitation of SiC bipolar devices originates from band-to-band recombination, which becomes significant at a high-injection level. A trial of unipolar/bipolar hybrid operation to reduce power loss is introduced, and an 11 kV SiC hybrid (merged pin-Schottky diodes is experimentally demonstrated. The fabricated diodes with an epitaxial anode exhibit much better forward characteristics than diodes with an implanted anode. The temperature dependence of forward characteristics is discussed.

  2. The discrete model of the power stage of the voltage source inverter for UPS

    Science.gov (United States)

    Rymarski, Zbigniew

    2011-10-01

    This article presents a new generalised discrete model of the power stage of single- and three-phase inverters including the calculations of the output filter parameters that provide an acceptable level of output voltage harmonics. The presented model can be used with the pole placement control methods such as the coefficient diagram method or the deadbeat one sampling ahead preview control. Discrete modelling of the power stage including properties of the PWM modulator makes an easy description of the chosen control law that can be directly implemented in the control software possible. The final simulation and the experimental verification of the poles placement methods in the voltage source inventer control confirm the usefulness of the presented model but some differences between the control theory and the inverter measurements are expected.

  3. A Consensus-Based Cooperative Control of PEV Battery and PV Active Power Curtailment for Voltage Regulation in Distribution Networks

    DEFF Research Database (Denmark)

    Zeraati, Mehdi; Golshan, Mohamad Esmail Hamedani; Guerrero, Josep M.

    2018-01-01

    The rapid growth of rooftop photovoltaic (PV) arrays installed in residential houses leads to serious voltage quality problems in low voltage distribution networks (LVDNs). In this paper, a combined method using the battery energy management of plug-in electric vehicles (PEVs) and the active power...... curtailment (APC) of PV arrays is proposed to regulate voltage in LVDNs with high penetration level of PV resources. A distributed control strategy composed of two consensus algorithms is used to reach an effective utilization of limited storage capacity of PEV battery considering its power/capacity and state...... of charge (SoC). A consensus control algorithm is also developed to fairly share the required power curtailment among PVs during overvoltage periods. The main objective is to mitigate the voltage rise due to the reverse power flow and to compensate the voltage drop resulting from the peak load. Overall...

  4. Calculation of harmonic losses and ampacity in low-voltage power cables when used for feeding large LED lighting loads

    Directory of Open Access Journals (Sweden)

    N. J. Milardovich

    2014-10-01

    Full Text Available A numerical investigation on the harmonic disturbances in low-voltage cables feeding large LED loads is reported. A frequency domain analysis on several commercially-available LEDs was performed to investigate the signature of the harmonic current injected into the power system. Four-core cables and four single-core cable arrangements (three phases and neutral of small, medium, and large conductor cross sections, with the neutral conductor cross section approximately equal to the half of the phase conductors, were examined. The cables were modelled by using electromagnetic finite-element analysis software. High harmonic power losses (up to 2.5 times the value corresponding to an undistorted current of the same rms value of the first harmonic of the LED current were found. A generalized ampacity model was employed for re-rating the cables. It was found that the cross section of the neutral conductor plays an important role in the derating of the cable ampacity due to the presence of a high-level of triplen harmonics in the distorted current. The ampacity of the cables should be derated by about 40 %, almost independent of the conductor cross sections. The calculation have shown that an incoming widespread use of LED lamps in lighting could create significant additional harmonic losses in the supplying low-voltage lines, and thus more severely harmonic emission limits should be defined for LED lamps.

  5. Solar powered high voltage energization for vehicular exhaust cleaning: A step towards possible retrofitting in vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Rajanikanth, B.S.; Mohapatro, Sankarsan [High Voltage Lab, Indian Institute of Science, Bangalore-560012 (India); Umanand, L. [CEDT, Indian Institute of Science, Bangalore-560012 (India)

    2009-03-15

    This paper proposes a novel way of generating high voltage for electric discharge plasma in controlling NO{sub x} emission in diesel engine exhaust. A solar powered high frequency electric discharge topology has been suggested that will improve the size and specific energy density required when compared to the traditional repetitive pulse or 50 Hz AC energization. This methodology has been designed, fabricated and experimentally verified by conducting studies on real diesel engine exhaust. (author)

  6. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation.

    Science.gov (United States)

    Choi, Hojong; Woo, Park Chul; Yeom, Jung-Yeol; Yoon, Changhan

    2017-04-04

    A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (-1.8 and -0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (-2.95 and -3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dBm input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity) of the HVPA with power MOSFET linearizer (24.17 and 26.19 dBm at 70 and 80 MHz, respectively) at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dBm at 70 and 80 MHz, respectively). To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dBm input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (-48.34, -44.21, -48.34, and -46.56 dB, respectively) were lower than that of the HVPA without the power MOSFET linearizer (-45.61, -41.57, -45.01, and -45.51 dB, respectively). When five-cycle 20 dBm input

  7. Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation

    Directory of Open Access Journals (Sweden)

    Hojong Choi

    2017-04-01

    Full Text Available A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (−1.8 and −0.96 dB, respectively compared to that of the HVPA without the power MOSFET linearizer (−2.95 and −3.0 dB, respectively when 70 and 80 MHz, three-cycle, and 26 dBm input pulse waveforms are applied, respectively. The input 1-dB compression point (an index of linearity of the HVPA with power MOSFET linearizer (24.17 and 26.19 dBm at 70 and 80 MHz, respectively at 10 V DC bias voltage was increased compared to that of HVPA without the power MOSFET linearizer (22.03 and 22.13 dBm at 70 and 80 MHz, respectively. To further verify the reduction of the echo harmonic distortion components generated by the ultrasonic transducers, the pulse-echo responses in the pulse-echo instrumentation were compared when using HVPA with and without the power MOSFET linearizer. When three-cycle 26 dBm input power was applied, the second, third, fourth, and fifth harmonic distortion components of a 75 MHz transducer driven by the HVPA with power MOSFET linearizer (−48.34, −44.21, −48.34, and −46.56 dB, respectively were lower than that of the HVPA without the power MOSFET linearizer (−45.61, −41.57, −45.01, and −45.51 d

  8. Recommended revised sections to line focus solar central power systems

    Energy Technology Data Exchange (ETDEWEB)

    1978-10-18

    The design requirements, subsystem characteristics, environmental requirements, and cost and performance evaluation techniques are defined for the Line Focus Solar Central Power Systems. Specific passages revised are enumerated. (LEW)

  9. MINI-UAV LIDAR FOR POWER LINE INSPECTION

    Directory of Open Access Journals (Sweden)

    G. E. Teng

    2017-09-01

    Full Text Available Light detection and ranging (LIDAR system based on unmanned aerial vehicles (UAVs recently are in rapid advancement, meanwhile portable and flexible mini-UAV-borne laser scanners have been a hot research field, especially for the complex terrain survey in the mountains and other areas. This study proposes a power line inspection system solution based on mini-UAV-borne LIDAR system–AOEagle, developed by Academy of Opto-Electronics, Chinese Academy of Sciences, which mounted on a Multi-rotor unmanned aerial vehicle for complex terrain survey according to real test. Furthermore, the point cloud data was explored to validate its applicability for power line inspection, in terms of corridor and line laser point clouds; deformation detection of power towers, etc. The feasibility and advantages of AOEagle have been demonstrated by the promising results based on the real-measured data in the field of power line inspection.

  10. Location of Faults in Power Transmission Lines Using the ARIMA Method

    Directory of Open Access Journals (Sweden)

    Danilo Pinto Moreira de Souza

    2017-10-01

    Full Text Available One of the major problems in transmission lines is the occurrence of failures that affect the quality of the electric power supplied, as the exact localization of the fault must be known for correction. In order to streamline the work of maintenance teams and standardize services, this paper proposes a method of locating faults in power transmission lines by analyzing the voltage oscillographic signals extracted at the line monitoring terminals. The developed method relates time series models obtained specifically for each failure pattern. The parameters of the autoregressive integrated moving average (ARIMA model are estimated in order to adjust the voltage curves and calculate the distance from the initial fault localization to the terminals. Simulations of the failures are performed through the ATPDraw ® (5.5 software and the analyses were completed using the RStudio ® (1.0.143 software. The results obtained with respect to the failures, which did not involve earth return, were satisfactory when compared with widely used techniques in the literature, particularly when the fault distance became larger in relation to the beginning of the transmission line.

  11. Voltage Feedback based Harmonic Compensation for an Offshore Wind Power Plant

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay K.; Lascu, Cristian; Teodorescu, Remus

    2016-01-01

    the harmonic distortion at the point of common coupling within the planning level limits using harmonic compensation, which is usually done by passive filters. In this paper a novel active harmonic compensation technique using voltage feedback from a non-local bus has been proposed and analyzed. Its......When an offshore wind power plant is connected to the grid, there is a risk of amplification of certain harmonics and appearance resonances at the point of connection due to the interaction between the grid network and the wind power plant network. Hence, the plant developer is obliged to maintain...

  12. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Science.gov (United States)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  13. Active power line conditioners design, simulation and implementation for improving power quality

    CERN Document Server

    Revuelta, Patricio Salmeron; Litrán, Salvador Pérez

    2015-01-01

    Active Power Line Conditioners: Design, Simulation and Implementation for Improving Power Quality presents a rigorous theoretical and practical approach to active power line conditioners, one of the subjects of most interest in the field of power quality. Its broad approach offers a journey that will allow power engineering professionals, researchers, and graduate students to learn more about the latest landmarks on the different APLC configurations for load active compensation. By introducing the issues and equipment needs that arise when correcting the lack of power quality in power grids

  14. Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment

    Directory of Open Access Journals (Sweden)

    Fernando Álvarez

    2015-03-01

    Full Text Available Partial discharge (PD measurements provide valuable information for assessing the condition of high voltage (HV insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. Non-conventional PD methods operating in high frequency bands are usually used when this type of tests are carried out. In PD measurements the signal acquisition, the subsequent signal processing and the capability to obtain an accurate diagnosis are conditioned by the selection of a suitable detection technique and by the implementation of effective signal processing tools. This paper proposes an optimized electromagnetic detection method based on the combined use of wideband PD sensors for measurements performed in the HF and UHF frequency ranges, together with the implementation of powerful processing tools. The effectiveness of the measuring techniques proposed is demonstrated through an example, where several PD sources are measured simultaneously in a HV installation consisting of a cable system connected by a plug-in terminal to a gas insulated substation (GIS compartment.

  15. Design of Voltage control Oscillator using Nonlinear Composite Right/Left-Handed Transmission Line

    Directory of Open Access Journals (Sweden)

    H. J. El-Khozondar

    2016-03-01

    Full Text Available In the present work, we propose a voltage control oscillator (VCO at high frequency consists of nonlinear composite right/left-handed transmission line (CRLH-TL loaded with Resonant Tunneling Diode (RTD. We designed three prototype device examples. The first one consists of one cell with short circuit at the beginning of the cell between ground and patch, and 50 Ω load resistance were added at the end of the cell between ground and patch. The second one is similar to the first prototype but with open circuit at the beginning of the cell instated of short circuit. The third prototype consists of one cell with two 50 Ω load resistances added between ground and patch at the beginning and at the end of the cell. The proposed VCO models are capable of generating oscillations at frequencies between 4.87- 14.9 GHz. In our simulations, we used OrCAD and ADS software to analyze the proposed circuit.

  16. Adaptive-Fuzzy Controller Based Shunt Active Filter for Power Line Conditioners

    Directory of Open Access Journals (Sweden)

    KamalaKanta Mahapatra

    2011-08-01

    Full Text Available This paper presents a novel Fuzzy Logic Controller (FLC in conjunction with Phase Locked Loop (PLL based shunt active filter for Power Line Conditioners (PLCs to improve the power quality in the distribution system. The active filter is implemented with current controlled Voltage Source Inverter (VSI for compensating current harmonics and reactive power at the point of common coupling. The VSI gate control switching pulses are derived from proposed Adaptive-Fuzzy-Hysteresis Current Controller (HCC and this method calculates the hysteresis bandwidth effectively using fuzzy logic. The bandwidth can be adjusted based on compensation current variation, which is used to optimize the required switching frequency and improves active filter substantially. These shunt active power filter system is investigated and verified under steady and transient-state with non-linear load conditions. This shunt active filter is in compliance with IEEE 519 and IEC 61000-3 recommended harmonic standards.

  17. Onboard power line conditioning system for an electric or hybrid vehicle

    Science.gov (United States)

    Kajouke, Lateef A.; Perisic, Milun

    2016-06-14

    A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

  18. Design and Tuning of Wind Power Plant Voltage Controller with Embedded Application of Wind Turbines and STATCOMs

    DEFF Research Database (Denmark)

    Petersen, Lennart; Kryezi, Fitim; Iov, Florin

    2017-01-01

    This study addresses a detailed design and tuning of a wind power plant voltage control with reactive power contribution of wind turbines and static synchronous compensators (STATCOMs). First, small-signal models of a single wind turbine and STATCOM are derived by using the state-space approach....... A complete phasor model of the entire wind power plant is constructed, being appropriate for voltage control assessment. An exemplary wind power plant located in the United Kingdom and the corresponding grid code requirements are used as a base case. The final design and tuning process of the voltage...... controller results in a guidance, proposed for this particular control architecture. It provides qualitative outcomes regarding the parametrisation of each individual control loop and how to adjust the voltage controller depending on different grid stiffnesses of the wind power plant connection...

  19. Distributed Control of Inverter-Based Lossy Microgrids for Power Sharing and Frequency Regulation Under Voltage Constraints

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chin-Yao; Zhang, Wei

    2016-01-19

    This paper presents a new distributed control framework to coordinate inverter-interfaced distributed energy resources (DERs) in island microgrids. We show that under bounded load uncertainties, the proposed control method can steer the microgrid to a desired steady state with synchronized inverter frequency across the network and proportional sharing of both active and reactive powers among the inverters. We also show that such convergence can be achieved while respecting constraints on voltage magnitude and branch angle differences. The controller is robust under various contingency scenarios, including loss of communication links and failures of DERs. The proposed controller is applicable to lossy mesh microgrids with heterogeneous R/X distribution lines and reasonable parameter variations. Simulations based on various microgrid operation scenarios are also provided to show the effectiveness of the proposed control method.

  20. Stabilizing control for power converters connected to transmission lines

    NARCIS (Netherlands)

    Zainea, Marius; Schaft, Arjan van der; Buisson, Jean

    2007-01-01

    This paper proposes a switching control strategy for the set-point stabilization of a power converter connected via a transmission line to a resistive load. The strategy employs a Lyapunov function that is directly based on energy considerations of the power converter, as well as of the transmission

  1. 47 CFR 15.113 - Power line carrier systems.

    Science.gov (United States)

    2010-10-01

    ... accomplish the desired purpose. No equipment authorization is required. (d) The best engineering principles...-interference basis in accordance with § 15.5 of this part. If harmful interference occurs, the electric power... frequencies. (e) Power line carrier system apparatus shall conform to such engineering standards as may be...

  2. PSO Based Optimal Location and Sizing of SVC for Novel Multiobjective Voltage Stability Analysis during N – 2 Line Contingency

    Directory of Open Access Journals (Sweden)

    Mangaiyarkarasi S.P.

    2014-12-01

    Full Text Available In this paper voltage stability is analysed based not only on the voltage deviations from the nominal values but also on the number of limit violating buses and severity of voltage limit violations. The expression of the actual state of the system as a numerical index like severity, aids the system operator in taking better security related decisions at control centres both during a period of contingency and also at a highly stressed operating condition. In contrary to conventional N – 1 contingency analysis, Northern Electric Reliability Council (NERC recommends N – 2 line contingency analysis. The decision of the system operator to overcome the present contingency state of the system must blend harmoniously with the stability of the system. Hence the work presents a novel N – 2 contingency analysis based on the continuous severity function of the system. The study is performed on 4005 possible combinations of N – 2 contingency states for the practical Indian Utility 62 bus system. Static VAr Compensator is used to improve voltage profile during line contingencies. A multi- objective optimization with the objective of minimizing the voltage deviation and also the number of limit violating bus with optimal location and optimal sizing of SVC is achieved by Particle Swarm Optimization algorithm.

  3. Evaluation of the probability of arrester failure in a high-voltage transmission line using a Q learning artificial neural network model

    Science.gov (United States)

    Ekonomou, L.; Karampelas, P.; Vita, V.; Chatzarakis, G. E.

    2011-04-01

    One of the most popular methods of protecting high voltage transmission lines against lightning strikes and internal overvoltages is the use of arresters. The installation of arresters in high voltage transmission lines can prevent or even reduce the lines' failure rate. Several studies based on simulation tools have been presented in order to estimate the critical currents that exceed the arresters' rated energy stress and to specify the arresters' installation interval. In this work artificial intelligence, and more specifically a Q-learning artificial neural network (ANN) model, is addressed for evaluating the arresters' failure probability. The aims of the paper are to describe in detail the developed Q-learning ANN model and to compare the results obtained by its application in operating 150 kV Greek transmission lines with those produced using a simulation tool. The satisfactory and accurate results of the proposed ANN model can make it a valuable tool for designers of electrical power systems seeking more effective lightning protection, reducing operational costs and better continuity of service.

  4. CLASSIFICATION OF POWER QUALITY CONSIDERING VOLTAGE SAGS IN DISTRIBUTION SYSTEMS USING KDD PROCESS

    Directory of Open Access Journals (Sweden)

    Anderson Roges Teixeira Góes

    2015-08-01

    Full Text Available In this paper, we propose a methodology to classify Power Quality (PQ in distribution systems based on voltage sags. The methodology uses the KDD process (Knowledge Discovery in Databases in order to establish a quality level to be printed in labels. The methodology was applied to feeders on a substation located in Curitiba, Paraná, Brazil, considering attributes such as sag length (remnant voltage, duration and frequency (number of occurrences on a given period of time. On the Data Mining Stage (the main stage on KDD Process, three different techniques were used, in a comparative way, for pattern recognition, in order to achieve the quality classification for the feeders: Artificial Neural Networks (ANN; Support Vector Machines (SVM and Genetic Algorithms (GA. By printing a label with quality level information, utilities companies (power concessionaires can get better organized for mitigation procedures by establishing clear targets. Moreover, the same way costumers already receive information regarding PQ based on interruptions, they will also be able to receive information based on voltage sags.

  5. Power grid current harmonics mitigation drawn on low voltage rated switching devices with effortless control

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Hugo S.; Anunciada, Victor; Borges, Beatriz V. [Power Electronics Group, Instituto de Telecomunicacoes, Lisbon (Portugal); Instituto Superior Tecnico - Universidade Tecnica de Lisboa, Lisbon (Portugal)

    2010-01-15

    The great majority of the existing hybrid active power filter solutions is normally focused in 3{phi} systems and, in general, concentrates its domain of application in specific loads with deterministic behavior. Because common use grids do not exhibit these characteristics, it is mandatory to develop solutions for more generic scenarios, encouraging the use of less classical hybrid solutions. In fact, due to the widely use of switch mode converters in a great variety of consumer electronics, the problematic of mains current harmonic mitigation is no longer an exclusive matter of 3{phi} systems. The contribution of this paper is to present a shunt hybrid active power filter topology, initially conceived to work in 1{phi} domestic grids, able to operate the inverter at a voltage rate that can be lower than 10% of the mains voltage magnitude, even under nonspecific working conditions. In addition, the results shown in this paper demonstrate that this topology can, without lack of generality, be suitable to medium voltage (1{phi} or 3{phi}) systems. A new control approach for the proposed topology is discussed in this paper. The control method exhibits an extremely simple architecture requiring single point current sensing only, with no need for any kind of reference. Its practical implementation can be fulfilled by using very few, common use, operational amplifiers. The principle of operation, design criteria, simulation predictions and experimental results are presented and discussed. (author)

  6. Cavity voltage phase modulation to reduce the high-luminosity Large Hadron Collider rf power requirements

    Science.gov (United States)

    Mastoridis, T.; Baudrenghien, P.; Molendijk, J.

    2017-10-01

    The Large Hadron Collider (LHC) radio frequency (rf) and low-level rf (LLRF) systems are currently configured for constant rf voltage to minimize transient beam loading effects. The present scheme cannot be extended beyond nominal LHC beam current (0.55 A dc) and cannot be sustained for the high-luminosity (HL-LHC) beam current (1.1 A dc), since the demanded power would exceed the peak klystron power. A new scheme has therefore been proposed: for beam currents above nominal (and possibly earlier), the voltage reference will reproduce the modulation driven by the beam (transient beam loading), but the strong rf feedback and one-turn delay feedback will still be active for loop and beam stability. To achieve this, the voltage reference will be adapted for each bunch. This paper includes a theoretical derivation of the optimal cavity modulation, introduces the implemented algorithm, summarizes simulation runs that tested the algorithm performance, and presents results from a short LHC physics fill with the proposed implementation.

  7. Cavity voltage phase modulation to reduce the high-luminosity Large Hadron Collider rf power requirements

    Directory of Open Access Journals (Sweden)

    T. Mastoridis

    2017-10-01

    Full Text Available The Large Hadron Collider (LHC radio frequency (rf and low-level rf (LLRF systems are currently configured for constant rf voltage to minimize transient beam loading effects. The present scheme cannot be extended beyond nominal LHC beam current (0.55 A dc and cannot be sustained for the high-luminosity (HL-LHC beam current (1.1 A dc, since the demanded power would exceed the peak klystron power. A new scheme has therefore been proposed: for beam currents above nominal (and possibly earlier, the voltage reference will reproduce the modulation driven by the beam (transient beam loading, but the strong rf feedback and one-turn delay feedback will still be active for loop and beam stability. To achieve this, the voltage reference will be adapted for each bunch. This paper includes a theoretical derivation of the optimal cavity modulation, introduces the implemented algorithm, summarizes simulation runs that tested the algorithm performance, and presents results from a short LHC physics fill with the proposed implementation.

  8. Optimal Design of a Resonance-Based Voltage Boosting Rectifier for Wireless Power Transmission.

    Science.gov (United States)

    Lim, Jaemyung; Lee, Byunghun; Ghovanloo, Maysam

    2018-02-01

    This paper presents the design procedure for a new multi-cycle resonance-based voltage boosting rectifier (MCRR) capable of delivering a desired amount of power to the load (PDL) at a designated high voltage (HV) through a loosely-coupled inductive link. This is achieved by shorting the receiver (Rx) LC-tank for several cycles to harvest and accumulate the wireless energy in the RX inductor before boosting the voltage by breaking the loop and transferring the energy to the load in a quarter cycle. By optimizing the geometries of the transmitter (Tx) and Rx coils and the number of cycles, N, for energy harvesting, through an iterative design procedure, the MCRR can achieve the highest PDL under a given set of design constraints. Governing equations in the MCRR operation are derived to identify key specifications and the design guidelines. Using an exemplary set of specs, the optimized MCRR was able to generate 20.9 VDC across a 100 kΩ load from a 1.8 Vp, 6.78 MHz sinusoid input in the ISM-band at a Tx/Rx coil separation of 1.3 cm, power transfer efficiency (PTE) of 2.2%, and N = 9 cycles. At the same coil distance and loading, coils optimized for a conventional half-wave rectifier (CHWR) were able to reach only 13.6 VDC from the same source.

  9. Analytical Assessment of Voltage Support via Reactive Power from new Electric Vehicles Supply Equipment in Radial Distribution Grids with Voltage-Dependent Loads

    DEFF Research Database (Denmark)

    Zecchino, Antonio; Marinelli, Mattia

    2018-01-01

    Grid operators have to cope with secure electric vehicles integration in the power system, which may lead to violations of the allowed voltage band. This work intends to provide an analytical assessment and guidelines for distribution system operators when evaluating new electric vehicle supply...

  10. Power electronic solutions for interfacing offshore wind turbine generators to medium voltage DC collection grids

    Science.gov (United States)

    Daniel, Michael T.

    Here in the early 21st century humanity is continuing to seek improved quality of life for citizens throughout the world. This global advancement is providing more people than ever with access to state-of-the-art services in areas such as transportation, entertainment, computing, communication, and so on. Providing these services to an ever-growing population while considering the constraints levied by continuing climate change will require new frontiers of clean energy to be developed. At the time of this writing, offshore wind has been proven as both a politically and economically agreeable source of clean, sustainable energy by northern European nations with many wind farms deployed in the North, Baltic, and Irish Seas. Modern offshore wind farms are equipped with an electrical system within the farm itself to aggregate the energy from all turbines in the farm before it is transmitted to shore. This collection grid is traditionally a 3-phase medium voltage alternating current (MVAC) system. Due to reactive power and other practical constraints, it is preferable to use a medium voltage direct current (MVDC) collection grid when siting farms >150 km from shore. To date, no offshore wind farm features an MVDC collection grid. However, MVDC collection grids are expected to be deployed with future offshore wind farms as they are sited further out to sea. In this work it is assumed that many future offshore wind farms may utilize an MVDC collection grid to aggregate electrical energy generated by individual wind turbines. As such, this work presents both per-phase and per-pole power electronic converter systems suitable for interfacing individual wind turbines to such an MVDC collection grid. Both interfaces are shown to provide high input power factor at the wind turbine while providing DC output current to the MVDC grid. Common mode voltage stress and circulating currents are investigated, and mitigation strategies are provided for both interfaces. A power sharing

  11. 30 CFR 75.704 - Grounding frames of stationary high-voltage equipment receiving power from ungrounded delta systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding frames of stationary high-voltage equipment receiving power from ungrounded delta systems. 75.704 Section 75.704 Mineral Resources MINE SAFETY...-UNDERGROUND COAL MINES Grounding § 75.704 Grounding frames of stationary high-voltage equipment receiving...

  12. Containment and Consensus-based Distributed Coordination Control for Voltage Bound and Reactive Power Sharing in AC Microgrid

    DEFF Research Database (Denmark)

    Han, Renke; Meng, Lexuan; Ferrari-Trecate, Giancarlo

    2017-01-01

    This paper offers a highly flexible and reliable control strategy to achieve voltage bounded regulation and accurate reactive power sharing coordinately in AC Micro-Grids. A containment and consensus-based distributed coordination controller is proposed, by which each output voltage magnitude can...

  13. A New Approach to High Efficincy in Isolated Boost Converters for High-Power Low-Voltage Fuel Cell Apllications

    DEFF Research Database (Denmark)

    Nymand, Morten; Andersen, Michael A. E.

    2008-01-01

    A new low-leakage-inductance low-resistance design approach to low-voltage high-power isolated boost converters is presented. Very low levels of parasitic circuit inductances are achieved by optimizing transformer design and circuit lay-out. Primary side voltage clamp circuits can be eliminated b...

  14. A High-Voltage class-D power amplifier with switching frequency regulation for improved high-efficiency output power range

    NARCIS (Netherlands)

    Ma, H.; van der Zee, Ronan A.R.; Nauta, Bram

    2015-01-01

    This paper describes the power dissipation analysis and the design of an efficiency-improved high-voltage class-D power amplifier. The amplifier adaptively regulates its switching frequency for optimal power efficiency across the full output power range. This is based on detecting the switching

  15. Operational Experience of the World's First Transmission Level Voltage Hts Power Cable

    Science.gov (United States)

    Maguire, J. F.; Yuan, J.; Schmidt, F.; Soika, R.; Bratt, S.; King, C.; McNamara, J.; Welsh, T. E.

    2010-04-01

    Underground High Temperature Superconductor (HTS) power cables have attracted extensive interest in recent years due to their potential for high power density. With funding support from the United States Department of Energy (DOE), the world's first transmission voltage level HTS power cable has been designed, fabricated and permanently installed in Long Island Power Authority (LIPA) grid. The HTS cable was successfully commissioned on April 22, 2008 and has been in operation since then. The three phase cable is 600 meter long and was designed to carry 574 MVA at a voltage of 138 kV. The project is being led by American Superconductor (AMSC). The team is comprised of Nexans, Air Liquide and LIPA. This paper describes the operational experience of the cable and refrigeration system since energization. A detailed description of various events and lessons learned over the course of operation is presented. The cable system performance is compared before and after more than one year of in-grid operation. In addition, the status and progress of the recently awarded LIPA II project is included.

  16. Assessment of surge arrester failure rate and application studies in Hellenic high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, C.A.; Fotis, G.P.; Gonos, I.F.; Stathopulos, I.A. [National Technical University of Athens, School of Electrical and Computer Engineering, High Voltage Laboratory, 9 Iroon Politechniou St., Zografou Campus, 157 80 Athens (Greece); Ekonomou, L. [A.S.PE.T.E. - School of Pedagogical and Technological Education, Department of Electrical Engineering Educators, N. Heraklion, 141 21 Athens (Greece)

    2010-02-15

    The use of transmission line surge arresters to improve the lightning performance of transmission lines is becoming more common. Especially in areas with high soil resistivity and ground flash density, surge arresters constitute the most effective protection mean. In this paper a methodology for assessing the surge arrester failure rate based on the electrogeometrical model is presented. Critical currents that exceed arresters rated energy stress were estimated by the use of a simulation tool. The methodology is applied on operating Hellenic transmission lines of 150 kV. Several case studies are analyzed by installing surge arresters on different intervals, in relation to the region's tower footing resistance and the ground flash density. The obtained results are compared with real records of outage rate showing the effectiveness of the surge arresters in the reduction of the recorded failure rate. The presented methodology can be proved valuable to the studies of electric power systems designers intending in a more effective lightning protection, reducing the operational costs and providing continuity of service. (author)

  17. Mitigation of voltage sag, swell and power factor correction using solid-state transformer b

    Directory of Open Access Journals (Sweden)

    M.R. Banaei

    2014-09-01

    Full Text Available This paper presents a novel topology of solid-state transformer (SST. In the design process, the AC/DC, DC/AC and AC/AC converters have been integrated to achieve higher efficiency. To obtain higher efficiency from other SST with DC-link topologies, the AC/DC and DC/AC converters have been integrated in one matrix converter. The proposed SST performs typical functions and has advantages such as power factor correction, voltage sag and swell elimination, voltage flicker reduction and protection capability in fault situations. In addition, it has other benefits such as light weight, low volume and elimination of hazardous liquid dielectrics because it uses medium frequency transformer. The operation and some performances of the proposed SST have been verified by the simulation results.

  18. Plasma sheath effects and voltage distributions of large high-power satellite solar arrays

    Science.gov (United States)

    Parker, L. W.

    1979-01-01

    Knowledge of the floating voltage configuration of a large array in orbit is needed in order to estimate various plasma-interaction effects. The equilibrium configuration of array voltages relative to space depends on the sheath structure. The latter dependence for an exposed array is examined in the light of two finite-sheath effects. One effect is that electron currents may be seriously underestimated. The other is that a potential barrier for electrons can occur, restricting electron currents. A conducting surface is assumed on the basis of a conductivity argument. Finite-sheath effects are investigated. The results of assuming thin-sheath and thick-sheath limits on the floating configuration of a linearly connected array are studied. Sheath thickness and parasitic power leakage are estimated. Numerically computed fields using a 3-D code are displayed in the thick-sheath limit.

  19. Soft switching (ZVZCS) high current, low voltage modular power converter (13 kA, 16 V)

    CERN Document Server

    Bordry, Frederick; Thiesen, H

    2001-01-01

    The Large Hadron Collider (LHC) is the next accelerator being constructed at the European Laboratory for Particle Physics (CERN). The superconducting LHC particle accelerator requires high currents (13 kA) and relatively low voltages (16 V) for its magnets. This paper describes the development and the production of a (13 kA, 16 V) power converter. The converter is made with a modular concept with five current sources (3.25 kA, 16 V) in parallel. The 3.25 kA sources are built as plug-in modules: a diode rectifier on the AC mains, a zero voltage zero current switching (ZVZCS) inverter working at 25 k Hz and an output stage. The obtained performance is presented and discussed. (6 refs).

  20. Design, Implementation, Modeling, and Optimization of Next Generation Low-Voltage Power MOSFETs

    Science.gov (United States)

    Yoo, Abraham

    In this thesis, next generation low-voltage integrated power semiconductor devices are proposed and analyzed in terms of device structure and layout optimization techniques. Both approaches strive to minimize the power consumption of the output stage in DC-DC converters. In the first part of this thesis, we present a low-voltage CMOS power transistor layout technique, implemented in a 0.25mum, 5 metal layer standard CMOS process. The hybrid waffle (HW) layout was designed to provide an effective trade-off between the width of diagonal source/drain metal and the active device area, allowing more effective optimization between switching and conduction losses. In comparison with conventional layout schemes, the HW layout exhibited a 30% reduction in overall on-resistance with 3.6 times smaller total gate charge for CMOS devices with a current rating of 1A. Integrated DC-DC buck converters using HW output stages were found to have higher efficiencies at switching frequencies beyond multi-MHz. In the second part of the thesis, we present a CMOS-compatible lateral superjunction FINFET (SJ-FINFET) on a SOI platform. One drawback associated with low-voltage SJ devices is that the on-resistance is not only strongly dependent on the drift doping concentration but also on the channel resistance as well. To resolve the issue, a SJ-FINFET structure consisting of a 3D trench gate and SJ drift region was developed to minimize both channel and drift resistances. Several prototype devices were fabricated in a 0.5mum CMOS compatible process with nine masking layers. In comparison with conventional SJ-LDMOSFETs, the fabricated SJ-FINFETs demonstrated approximately 30% improvement in Ron,sp. This is a positive indication that the SJ-FINFET can become a competitive power device for sub-100V rating applications.

  1. A Single-Phase Voltage-Controlled Grid-Connected Photovoltaic System With Power Quality Conditioner Functionality

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Liserre, Marco; Mastromauro, R. A.

    2009-01-01

    Future ancillary services provided by photovoltaic (PV) systems could facilitate their penetration in power systems. Also low power PV systems can be designed to improve the power quality. This paper presents a single-phase photovoltaic system that provides grid voltage support and compensation...... of harmonic distortion at the point of common coupling (PCC) thanks to a repetitive controller. The power provided by the PV panels is controlled by a Maximum Power Point Tracking (MPPT) algorithm based on the incremental conductance method specifically modified to control the phase of the PV inverter voltage...

  2. Voltage stability issues for a benchmark grid model including large scale wind power

    DEFF Research Database (Denmark)

    Eek, Jarle; Lund, Torsten; Di Marzio, Guiseppe

    2006-01-01

    The objective of the paper is to investigate how the voltage stability of a relatively weak network after a grid fault is affected by the connection of a large wind park. A theoretical discussion of the stationary and dynamic characteristics of the Short Circuit Induction Generator and the Doubly...... Fed Induction Generator is given. Further, a case study of a wind park connected to the transmission system through an existing regional 132 kV regional distribution line is presented. For the SCIG it is concluded that a stationary torque curve calculated under consideration of the impedance...

  3. High voltage-power frequency electrical heating in-situ conversion technology of oil shale

    Science.gov (United States)

    Sun, Youhong; Yang, Yang; Lopatin, Vladimir; Guo, Wei; Liu, Baochang; Yu, Ping; Gao, Ke; Ma, Yinlong

    2014-05-01

    With the depletion of conventional energy sources,oil shale has got much attention as a new type of energy resource,which is rich and widespread in the world.The conventional utilization of oil shale is mainly focused on resorting to produce shale oil and fuel gas with low extraction efficiency about one in a million due to many shortcomings and limitations.And the in-situ conversion of oil shale,more environmentally friendly,is still in the experimental stage.High voltage-power frequency electrical heating in-situ conversion of oil shale is a new type of in-situ pyrolysis technology.The main equipment includes a high voltage-power frequency generator and interior reactor. The high voltage-power frequency generator can provide a voltage between 220-8000 V which can be adjusted in real time according to the actual situation.Firstly,high voltage is used to breakdown the oil shale to form a dendritic crack between two electrodes providing a conductive channel inside the oil shale rock.And then the power frequency(220V) is used to generate the electric current for heating the internal surface of conductive channel,so that the energy can be transmitted to the surrounding oil shale.When the temperature reaches 350 degree,the oil shale begins to pyrolysis.In addition,the temperature in the conductive channel can be extremely high with high voltage,which makes the internal surface of conductive channel graphitization and improves its heat conduction performance.This technology can successfully make the oil shale pyrolysis, based on a lot of lab experiments,and also produce the combustible shale oil and fuel gas.Compared to other in-situ conversion technology,this method has the following advantages: high speed of heating oil shale,the equipment underground is simple,and easy to operate;it can proceed without the limitation of shale thickness, and can be used especially in the thin oil shale reservoir;the heating channel is parallel to the oil shale layers,which has more

  4. Loss Distribution and Thermal Behaviour of the Y-source Converter for a Wide Power and Voltage Range

    DEFF Research Database (Denmark)

    Gadalla, Brwene Salah Abdelkarim; Schaltz, Erik; Siwakoti, Yam Prasad

    2017-01-01

    The Y-source converter is one of the recent proposed impedance source converters. It has some advantages as having a high voltage gain between the input and output voltage sides using very small duty cycle ratios. For many applications, the input voltage needs to be boosted to higher output voltage...... and power range is presented. The influence of the heat losses generated in the converter is also considered for different analysis. A simulation model is developed and verified experimentally rated at 300 W....

  5. Novel Auto-Reclosing Blocking Method for Combined Overhead-Cable Lines in Power Networks

    Directory of Open Access Journals (Sweden)

    Ricardo Granizo Arrabé

    2016-11-01

    Full Text Available This paper presents a novel auto-reclosing blocking method for combined overhead-cable lines in power distribution networks that are solidly or impedance grounded, with distribution transformers in a delta connection in their high-voltage sides. The main contribution of this new technique is that it can detect whether a ground fault has been produced at the overhead line side or at the cable line side, thus improving the performance of the auto-reclosing functionality. This localization technique is based on the measurements and analysis of the argument differences between the load currents in the active conductors of the cable and the currents in the shields at the cable end where the transformers in delta connection are installed, including a wavelet analysis. This technique has been verified through computer simulations and experimental laboratory tests.

  6. Inductive coupling between overhead power lines and nearby metallic pipelines. A neural network approach

    Directory of Open Access Journals (Sweden)

    Levente Czumbil

    2015-12-01

    Full Text Available The current paper presents an artificial intelligence based technique applied in the investigation of electromagnetic interference problems between high voltage power lines (HVPL and nearby underground metallic pipelines (MP. An artificial neural network (NN solution has been implemented by the authors to evaluate the inductive coupling between HVPL and MP for different constructive geometries of an electromagnetic interference problem considering a multi-layer soil structure. Obtained results are compared to solutions provided by a finite element method (FEM based analysis and considered as reference. The advantage of the proposed method yields in a simplified computation model compared to FEM, and implicitly a lower computational time.

  7. Design and Development of a control system for the Drift Tube Chamber High Voltage Power Supply

    CERN Document Server

    Leon Vega, Luis Gerardo

    2017-01-01

    This paper contains information related to the design and development of a control and data acquisition manager implemented in WinCC, a Siemens SCADA system. The goal was to manage a CAEN HV (High Voltage) system for powering a Drift Tube (DT) chamber of the CMS experiment. Basically, this manager consists of two sections: a friendly user interface and powerful scripts to manage the back-end. It is in charge of adjusting the power supply settings to the correct values needed for the DT Chamber operations (ON, OFF, Standby), depending of the requirements of the operator, managing automatically all the transition process. Also, the manager is in charge of configuring the archiving process for acquiring data and providing the history of the system. It also implements the monitoring of the status of each connected channel, alerting in case it is needed.

  8. Shunt hybrid active power filter under nonideal voltage based on fuzzy logic controller

    Science.gov (United States)

    Dey, Papan; Mekhilef, Saad

    2016-09-01

    In this paper, a synchronous reference frame (SRF) method based on a modified phase lock loop (PLL) circuit is developed for a three-phase four-wire shunt hybrid active power filter (APF). Its performance is analysed under unbalanced grid conditions. The dominant lower order harmonics as well as reactive power can be compensated by the passive elements, whereas the active part mitigates the remaining distortions and improves the power quality. As different control methods show contradictory performance, fuzzy logic controller is considered here for DC-link voltage regulation of the inverter. Extensive simulations of the proposed technique are carried out in a MATLAB-SIMULINK environment. A laboratory prototype has been built on dSPACE1104 platform to verify the feasibility of the suggested SHAPF controller. The simulation and experimental results validate the effectiveness of the proposed technique.

  9. Local Reactive Power Control Methods for Overvoltage Prevention of Distributed Solar Inverters in Low-Voltage Grids

    DEFF Research Database (Denmark)

    Demirok, Erhan; Gonzalez, Pablo Casado; Frederiksen, Kenn H. B.

    2011-01-01

    voltage (LV) grids by means of solar inverters with reactive power control capability. This paper underlines weak points of standard reactive power strategies which are already imposed by certain grid codes, and then, the study introduces a new reactive power control method that is based on sensi...

  10. Shunt capacitors for a.c. power systems having a rated voltage above 1000 V - Part 1: General

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2005-01-01

    This part of IEC 60871 is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage above 1 000 V and frequencies of 15 Hz to 60 Hz. This part of IEC 60871 also applies to capacitors intended for use in power filter circuits.

  11. The monitoring results of electromagnetic radiation of 110-kV high-voltage lines in one urban location in Chongqing P.R. China.

    Science.gov (United States)

    Qin, Qi-Zhong; Chen, Yu; Fu, Ting-Ting; Ding, Li; Han, Ling-Li; Li, Jian-Chao

    2012-03-01

    To understand electromagnetic radiation field strength and its influencing factors of certain 110-kV high-voltage lines in one urban area of Chongqing by measuring 110-kV high-voltage line's electromagnetic radiation level. According to the methodology as determined by the National Hygienic Standards, we selected certain adjacent residential buildings, high-voltage lines along a specific street and selected different distances around its vertical projection point as monitoring points. The levels of electromagnetic radiations were measured respectively. In this investigation within the frequency of 5-1,000 Hz both the electric field strength and magnetic field strength of each monitoring sites were lower than the public exposure standards as determined by the International Commission on Non-Ionizing Radiation Protection. However, the electrical field strength on the roof adjacent to the high-voltage lines was significantly higher than that as measured on the other floors in the same buildings (p electromagnetic radiation measurements of different monitoring points, under the same high-voltage lines, showed the location which is nearer the high-voltage line maintain a consistently higher level of radiation than the more distant locations (p Electromagnetic radiation generated by high-voltage lines decreases proportionally to the distance from the lines. The buildings can to some extent shield (or absorb) the electric fields generated by high-voltage lines nearby. The electromagnetic radiation intensity near high-voltage lines may be mitigated or intensified by the manner in which the high-voltage lines are set up, and it merits attention for the potential impact on human health.

  12. Arcing Faults Location Methods for Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mateusz Pustułka

    2014-03-01

    Full Text Available This paper presents three different fault location approaches: one-end Takagi algorithm, two-end algorithm considering natural fault loops and neural network. It is assumed that three-phase voltages and currents from both ends of the line measured asynchronously are the input signals of the fault locator. In addition to natural fault loop signals also the use of symmetrical components (positive and negative or incremental positive sequence components for fault location were considered. Results of the evaluation study have been included, analyzed and discussed. The impact of filtration has also been considered.

  13. Technical-parameter calculation model for underground low-power electrical lines and indoor installations used in telecommunications

    Directory of Open Access Journals (Sweden)

    Henry Bastidas Mora

    2011-09-01

    Full Text Available This article presents an analysis of electrical distribution theory for 60Hz-lines operating at low voltage, particularly underground lines and residential indoor installations. Such distribution lines’ behaviour is observed as a function of frequency to consider any advantages regarding the potential use of power transmission lines (PTL for transmitting telecommunication signals. A method for computing the secondary parameters is proposed which has been based on the primary parameters, namely inductance, capacitance, conductance and resistance. The secondary parameters so obtained were characteristic impedance, propagation constant (together with its real value and the attenuation constant. Conductor configurations, insulation materials and gauges commonly used in Colombia were verified for such low-voltage lines. A mathematical model is proposed as a theoretical tool for analysing and predicting characteristic impedance pattern and the attenuations which occur at high frequencies, thereby complementing our group’s previous work. Conclusions are drawn, together with a perspective regarding future work and applications.

  14. Transient Recovery Voltages at the Main 132kV Line Bay GIS Circuit Breaker in a Windfarm

    DEFF Research Database (Denmark)

    Arana Aristi, Iván; Okholm, J.; Holbøll, Joachim

    2011-01-01

    This paper presents the results of investigations of the Transient Recovery Voltage (TRV) across the terminals of the main 132kV Line Bay GIS circuit breaker (GIS CB) for Walney 2, second phase of the Walney Offshore Wind Farm. Several simulations were performed where the influence of different...... parameters in the network was evaluated during a fault in the onshore substation. The rate of rise of recovery voltage (RRRV) and the maximum crest voltage (Uc) of the TRV across the GIS CB were compared against the standard values based on the type test results from the GIS. The investigations were...... performed by means of time domain simulations using the EMT software PSCAD/HVDC. Based on the results, it was concluded that the highest RRRV appears on a system without additional stray capacitances, and the highest Uc appears when the fault is a single phase to ground....

  15. Monitoring the metering performance of an electronic voltage transformer on-line based on cyber-physics correlation analysis

    Science.gov (United States)

    Zhang, Zhu; Li, Hongbin; Tang, Dengping; Hu, Chen; Jiao, Yang

    2017-10-01

    Metering performance is the key parameter of an electronic voltage transformer (EVT), and it requires high accuracy. The conventional off-line calibration method using a standard voltage transformer is not suitable for the key equipment in a smart substation, which needs on-line monitoring. In this article, we propose a method for monitoring the metering performance of an EVT on-line based on cyber-physics correlation analysis. By the electrical and physical properties of a substation running in three-phase symmetry, the principal component analysis method is used to separate the metering deviation caused by the primary fluctuation and the EVT anomaly. The characteristic statistics of the measured data during operation are extracted, and the metering performance of the EVT is evaluated by analyzing the change in statistics. The experimental results show that the method successfully monitors the metering deviation of a Class 0.2 EVT accurately. The method demonstrates the accurate evaluation of on-line monitoring of the metering performance on an EVT without a standard voltage transformer.

  16. High Current, Low Voltage Power Converter [20kA, 6V] LHC Converter Prototype

    CERN Document Server

    Jørgensen, H E; Dupaquier, A; Fernqvist, G

    1998-01-01

    The superconducting LHC accelerator requires high currents (~12.5kA) and relatively low voltages (~10 V) for its magnets. The need to install the power converters underground is the driving force for reduced volume and high efficiency. Moreover, the LHC machine will require a very high level of performance from the power converters, particularly in terms of DC stability, dynamic response and also in matters of EMC. To meet these requirements soft-switching techniques will be used. This paper describes the development of a [20kA,6V] power converter intended as a stable high-current source for D CCT calibration and an evaluation prototype for the future LHC converters. The converter is made with a modular concept with five current sources [4kA,6V] in parallel. The 4kA sources are built as plu g-in modules: a diode rectifier on the AC mains with a damped L-C passive filter, a Zero Voltage Switching inverter working at 20 kHz and an output stage (high frequency transformers, Schottky rectifi ers and output filter...

  17. PI and Fuzzy Control Strategies for High Voltage Output DC-DC Boost Power Converter - Hardware Implementation and Analysis

    DEFF Research Database (Denmark)

    Padmanaban, Sanjeevi Kumar; Blaabjerg, Frede; Siano, Pierluigi

    2016-01-01

    This paper presents the control strategies by Proportional-Integral (P-I) and Fuzzy Logic (FL) for a DC-DC boost power converter for high output voltage configuration. Standard DC-DC converters are traditionally used for high voltage direct current (HVDC) power transmission systems. But, lack its...... converter with inbuilt voltage-lift technique and overcome the aforementioned deficiencies. Further, the control strategy is adapted based on proportional-integral (P-I) and fuzzy logic, closed-loop controller to regulate the outputs and ensure the performances. Complete hardware prototype of EHV converter...

  18. Radiation-Tolerant Custom Made Low Voltage Power Supply System for ATLAS/TileCal Detector

    CERN Document Server

    Hruska, I; Calheiros, F; Némécek, S; Kotek, Z; Palacky, J; Price, J; Lokajícek, M; Tikhonov, A; Solin, A

    2007-01-01

    This paper describes custom made Low Voltage Power Supply (LVPS) system developed for the ATLAS – TileCal detector of the LHC (The Large Hadron Collider) particle accelerator at CERN, Geneva. The system is based on the use of only COTS (Commercial of The Shelf) components, is qualified to be radiation tolerant up to 40krad, and can operate in external DC magnetic field above 0.02 Tesla. The LVPS design described in this paper has been developed and produced for the ATLAS TileCal detector during the years 2001 – 2007.

  19. Excitation and voltage regulation for a 95 MVA surge-power generator

    CERN Document Server

    Bayer, K H

    1972-01-01

    The excitation equipment of the 95 MVA surge-power generator, which feeds the main ring magnets of the 28 GeV proton synchrotron at CERN in Geneva, is subject to certain abnormal requirements. They relate both to its dynamic control characteristics and to its accuracy of voltage regulation. These are essential in order to comply with the most stringent conditions made with respect to reproducibility of magnet cycles over the whole duration of an experimenting period of three to four weeks. A special control concept also ensures optimum results in this respect for the dynamic transition regions within a pulse cycle. (4 refs).

  20. Assessing Short-Term Voltage Stability of Electric Power Systems by a Hierarchical Intelligent System.

    Science.gov (United States)

    Xu, Yan; Zhang, Rui; Zhao, Junhua; Dong, Zhao Yang; Wang, Dianhui; Yang, Hongming; Wong, Kit Po

    2016-08-01

    In the smart grid paradigm, growing integration of large-scale intermittent renewable energies has introduced significant uncertainties to the operations of an electric power system. This makes real-time dynamic security assessment (DSA) a necessity to enable enhanced situational-awareness against the risk of blackouts. Conventional DSA methods are mainly based on the time-domain simulation, which are insufficiently fast and knowledge-poor. In recent years, the intelligent system (IS) strategy has been identified as a promising approach to facilitate real-time DSA. While previous works mainly concentrate on the rotor angle stability, this paper focuses on another yet increasingly important dynamic insecurity phenomenon-the short-term voltage instability, which involves fast and complex load dynamics. The problem is modeled as a classification subproblem for transient voltage collapse and a prediction subproblem for unacceptable dynamic voltage deviation. A hierarchical IS is developed to address the two subproblems sequentially. The IS is based on ensemble learning of random-weights neural networks and is implemented in an offline training, a real-time application, and an online updating pattern. The simulation results on the New England 39-bus system verify its superiority in both learning speed and accuracy over some state-of-the-art learning algorithms.