  1. Transmission by an Embedded System with Enhancements in Voice Processing Technologies

    Directory of Open Access Journals (Sweden)

    G.Sitha Annapurna

    2014-03-01

    Full Text Available The paper reports that the robot can transmit the data such as video, audio, images. The robot can be controlled using the human voice. There are two embedded systems first one is robot controlling system(MASTER which is used to control the robot, second one is voice controlled robot(SLAVE which responds according to the instructions coming from the controlling system. These two embedded systems are communicated through wireless. We can use anyone one of wireless protocols such as IR, NFC, Bluetooth, Zigbee, WI-FI in order to establish a bridge between the MASTER and SLAVE. The voice controlled robot can understand the instructions with the help of the voice recognition system. Spinx-4 is a speech recognizer system written entirely in the java programming language.Sphinx-4 started out as a port of Sphinx-3 to the Java programming language, but evolved into a recognizer designed to be much more flexible than Sphinx-3, thus becoming an excellent platform for speech research.Sphinx-4 is an HMM-based speech recognizer. HMM stands for Hidden Markov Models, Sphinx-4 are a type of statistical model In HMM based speech recognizers.

  2. Voice integrated systems

    Science.gov (United States)

    Curran, P. Mike

    1977-01-01

    The program at Naval Air Development Center was initiated to determine the desirability of interactive voice systems for use in airborne weapon systems crew stations. A voice recognition and synthesis system (VRAS) was developed and incorporated into a human centrifuge. The speech recognition aspect of VRAS was developed using a voice command system (VCS) developed by Scope Electronics. The speech synthesis capability was supplied by a Votrax, VS-5, speech synthesis unit built by Vocal Interface. The effects of simulated flight on automatic speech recognition were determined by repeated trials in the VRAS-equipped centrifuge. The relationship of vibration, G, O2 mask, mission duration, and cockpit temperature and voice quality was determined. The results showed that: (1) voice quality degrades after 0.5 hours with an O2 mask; (2) voice quality degrades under high vibration; and (3) voice quality degrades under high levels of G. The voice quality studies are summarized. These results were obtained with a baseline of 80 percent recognition accuracy with VCS.

  3. Research on Network Voice Transmission System Based on RTEMS%基于RTEMS的网络语音传输系统的研究

    Institute of Scientific and Technical Information of China (English)

    李顺

    2014-01-01

    Studies the key technologies on network voice transmission, which include VoIP principles, H.323 network communication protocol and SIP. A network audio transmission system which is characterized by recording, implements playback and remote transmission function-alities based on such research results. Designs S3C2410 development board as the hardware platform and selects the RTEMS real-time operating system as the software platform since it is a lightweight, real-time and open source operating system.%主要研究网络语音传输过成中的关键技术,包括:Voice over IP(VoIP)的原理、网络通信协议H.323和会话初始化协议(SIP)。在此基础上研究并实现一个具有录音、放音、远程传输音频数据的网络音频系统。该网络音频传输系统是在以S3C2410嵌入式处理器为核心的硬件开发平台,RTEMS为软件平台的基础上进行开发,可以通过网络传送声音数据。

  4. Fibre Optic Bus Network For Voice And Data Transmission In A Ship

    Science.gov (United States)

    Jhunjhunwala, Ashok; Sanghi, R. K.; Manjunath, D.

    1987-12-01

    A versatile communication system in a ship with 120 stations, each having voice and data transmission is envisaged. The proposed fibre optic network has a bus topology ideally suited for distribution in ship-like environment. Use has been made of standard ETHERNET chip sets manufactured by INTEL. This makes the stations compact, easier to maintain and inexpensive. The ETHERNET proto-col is primarily designed for packet data transmission. The collision detection and backoff protocol makes the packet transmission probabilistic and is therefore not suitable for voice transmission. This problem is overcome in the present design by a scheme where the required number of voice slots are dynamically allocated. That is, having established a connection for voice communication between stations, fixed slots are assigned for voice transmission and reception. The data transmission continues to use CSMA/CD Protocol. A simple hardware addition to the ETHERNET chip set makes the scheme workable. Drops in the fiber optic bus network is through passive star couplers. Four to eight star couplers are used in the present scheme with repeaters between adjacent star couplers. The repeaters will not be usual repeaters, as ordinary repeaters would cause loops to be formed between adjacent stars, thereby causing data to recirculate. This recirculation is avoided by making the repeater intelligent and also performing the task of detecting collisions between signals originating from stations connected to different star couplers.

  5. Remote Voice Detection System

    Science.gov (United States)

    2007-06-25

    back to the laser Doppler vibrometer and the digital camera, respectively. Mechanical beam steering mirror modules, such as galvanometer steering...mirror module 43 in accordance with this invention. An appropriate galvanometer -based tracker system has been used for tracking eye motion during laser

  6. LABORATORY VOICE DATA ENTRY SYSTEM.

    Energy Technology Data Exchange (ETDEWEB)

    PRAISSMAN,J.L.SUTHERLAND,J.C.

    2003-04-01

    We have assembled a system using a personal computer workstation equipped with standard office software, an audio system, speech recognition software and an inexpensive radio-based wireless microphone that permits laboratory workers to enter or modify data while performing other work. Speech recognition permits users to enter data while their hands are holding equipment or they are otherwise unable to operate a keyboard. The wireless microphone allows unencumbered movement around the laboratory without a ''tether'' that might interfere with equipment or experimental procedures. To evaluate the potential of voice data entry in a laboratory environment, we developed a prototype relational database that records the disposal of radionuclides and/or hazardous chemicals Current regulations in our laboratory require that each such item being discarded must be inventoried and documents must be prepared that summarize the contents of each container used for disposal. Using voice commands, the user enters items into the database as each is discarded. Subsequently, the program prepares the required documentation.

  7. 短距离多点无线语音传输系统的设计与实现%Design and Implementation of Short-Range Multi-Point Wireless Voice Transmission System

    Institute of Scientific and Technical Information of China (English)

    陈成明; 虞丽娟; 曹守启

    2016-01-01

    结合ST M32单片机,研究短距离多点无线语音通信系统的开发,探讨系统软硬件的可行性设计。通过配置硬件模块和功能软件,构建短距离多点无线语音传输系统的理论模型。结果表明:设计的系统拓宽了市面上现有对讲机的内嵌功能和使用范围,既不受信号网络覆盖局限的影响,又无需信息服务费,而且在技术层面改变传统对讲机同频单工的通信模式,实现了多点间无线语音广播、组播和单播功能。%This paper studied the development of short range multi point wireless voice communication system,combined with STM32 single chip microcomputer and discussed the feasibility of the system hardware and software design.It con-structs the theoretical model of short range multi point wireless voice transmission system,by configuring the hardware modules and functional software.Result shows that the system has been designed to expand the inter embed function and using scope of the commercial interphone.It is not affected by the limitation of signal network coverage and doesn′t need information service fee.At the technical level,it has changed the traditional mode of communication with the radio fre-quency simplex.At the same time,it has realized the multi point wireless voice broadcast,multicast and unicast function.

  8. Improving Quality of Voice Conversion Systems

    Science.gov (United States)

    Farhid, M.; Tinati, M. A.

    New improvement scheme for voice conversion are proposed in this paper. We take Human factor cepstral coefficients (HFCC), a modification of MFCC that uses the known relationship between center frequency and critical bandwidth from human psychoacoustics to decouple filter bandwidth from filter spacing, as the basic feature. We propose U/V (Unvoiced/Voiced) decision rule such that two sets of codebooks are used to capture the difference between unvoiced and voiced segments of the source speaker. Moreover, we apply three schemes to refine the synthesized voice, including pitch refinement, energy equalization, and frame concatenation. The acceptable performance of the voice conversion system can be verified through ABX listening test and MOS grad.

  9. Voice Quality in Mobile Telecommunication System

    Directory of Open Access Journals (Sweden)

    Evaldas Stankevičius

    2013-05-01

    Full Text Available The article deals with methods measuring the quality of voice transmitted over the mobile network as well as related problem, algorithms and options. It presents the created voice quality measurement system and discusses its adequacy as well as efficiency. Besides, the author presents the results of system application under the optimal hardware configuration. Under almost ideal conditions, the system evaluates the voice quality with MOS 3.85 average estimate; while the standardized TEMS Investigation 9.0 has 4.05 average MOS estimate. Next, the article presents the discussion of voice quality predictor implementation and investigates the predictor using nonlinear and linear prediction methods of voice quality dependence on the mobile network settings. Nonlinear prediction using artificial neural network resulted in the correlation coefficient of 0.62. While the linear prediction method using the least mean squares resulted in the correlation coefficient of 0.57. The analytical expression of voice quality features from the three network parameters: BER, C / I, RSSI is given as well.Article in Lithuanian

  10. Resource Planning for Voice over Wireless Both-Way Transmission Media

    Directory of Open Access Journals (Sweden)

    B. Tsankov

    2008-04-01

    Full Text Available The medium in IEEE 802.11- and IEEE 802.16-based networks for voice communications can be considered "both-way" - for transmission and reception. Therefore, the packet arrivals for voice dialogue services in such networks are not strictly independent. In this paper, we discuss the traffic capacity in the call (network layer and suggest accounting for the impact of the correlated nature of two-way voice conversations on performance estimation. We present analytical results and numerical examples.

  11. METHODS FOR QUALITY ENHANCEMENT OF USER VOICE SIGNAL IN VOICE AUTHENTICATION SYSTEMS

    Directory of Open Access Journals (Sweden)

    O. N. Faizulaieva

    2014-03-01

    Full Text Available The reasonability for the usage of computer systems user voice in the authentication process is proved. The scientific task for improving the signal/noise ratio of the user voice signal in the authentication system is considered. The object of study is the process of input and output of the voice signal of authentication system user in computer systems and networks. Methods and means for input and extraction of voice signal against external interference signals are researched. Methods for quality enhancement of user voice signal in voice authentication systems are suggested. As modern computer facilities, including mobile ones, have two-channel audio card, the usage of two microphones is proposed in the voice signal input system of authentication system. Meanwhile, the task of forming a lobe of microphone array in a desired area of voice signal registration (100 Hz to 8 kHz is solved. The usage of directional properties of the proposed microphone array gives the possibility to have the influence of external interference signals two or three times less in the frequency range from 4 to 8 kHz. The possibilities for implementation of space-time processing of the recorded signals using constant and adaptive weighting factors are investigated. The simulation results of the proposed system for input and extraction of signals during digital processing of narrowband signals are presented. The proposed solutions make it possible to improve the value of the signal/noise ratio of the useful signals recorded up to 10, ..., 20 dB under the influence of external interference signals in the frequency range from 4 to 8 kHz. The results may be useful to specialists working in the field of voice recognition and speaker’s discrimination.

  12. Down hole transmission system

    Science.gov (United States)

    Hall, David R.; Hall, Jr., H. Tracy

    2007-07-24

    A transmission system in a downhole component comprises a data transmission element in both ends of the downhole component. Each data transmission element houses an electrically conducting coil in a MCEI circular trough. The electrically conducting coil comprises at least two generally fractional loops. In the preferred embodiment, the transmission elements are connected by an electrical conductor. Preferably, the electrical conductor is a coaxial cable. Preferably, the MCEI trough comprises ferrite. In the preferred embodiment, the fractional loops are connected by a connecting cable. In one aspect of the present invention, the connecting cable is a pair of twisted wires. In one embodiment the connecting cable is a shielded pair of twisted wires. In another aspect of the present invention, the connecting cable is a coaxial cable. The connecting cable may be disposed outside of the MCEI circular trough.

  13. Voice Activated Cockpit Management Systems: Voice-Flight NexGen Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Speaking to the cockpit as a method of system management in flight can become an effective interaction method, since voice communication is very efficient. Automated...

  14. Probabilistic transmission system planning

    CERN Document Server

    Li, Wenyuan

    2011-01-01

    "The book is composed of 12 chapters and three appendices, and can be divided into four parts. The first part includes Chapters 2 to 7, which discuss the concepts, models, methods and data in probabilistic transmission planning. The second part, Chapters 8 to 11, addresses four essential issues in probabilistic transmission planning applications using actual utility systems as examples. Chapter 12, as the third part, focuses on a special issue, i.e. how to deal with uncertainty of data in probabilistic transmission planning. The fourth part consists of three appendices, which provide the basic knowledge in mathematics for probabilistic planning. Please refer to the attached table of contents which is given in a very detailed manner"--

  15. DSP Based System for Real time Voice Synthesis Applications Development

    CERN Document Server

    Arsinte, Radu; Miron, Costin

    2008-01-01

    This paper describes an experimental system designed for development of real time voice synthesis applications. The system is composed from a DSP coprocessor card, equipped with an TMS320C25 or TMS320C50 chip, voice acquisition module (ADDA2),host computer (IBM-PC compatible), software specific tools.

  16. Increase in Organization Effectiveness Using Voice Analysis: The System Approach

    Directory of Open Access Journals (Sweden)

    Lina Bartkienė

    2011-04-01

    Full Text Available The main purpose of this article is to analyze literature related to the system theory and to present the system of increase in organization effectiveness using voice analysis. The concepts of the system approach were analyzed, the definition of the system, its components and classification were discussed. Following the principles of the system theory, the system of increase in organization effectiveness using voice analysis was designed. Each element was briefly discussed, i.e. processes influencing the employee, the environment, voice analysis system, expert system, prime and final organizational effectiveness. In addition, the relations between these elements were indentified. Article in Lithuanian

  17. NB Power Transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, J. [NB Power Transmission, Fredericton, NB (Canada)

    2006-07-01

    The NB Power Transmission System operates 6700 km of transmission lines having voltages of 69 kV, 138 kV, 230 kV, and 345 kV. The history of lightning protection on this transmission system was presented. Lightning protection with shield wires has been applied selectively on the 69 kV and 138 kV lines and has been applied to all lines in the 230 kV and 345 kV range. Beginning in 2000, line arresters were installed on selected 69 kV and 138 kV lines. It was noted that although overhead shield wires are commonly installed to capture lightning strikes and shield the conductors, problems can occur if the electrical flashover of insulators result in a line to ground fault. Good grounding is needed to ensure that lightning enters the ground from the tower. The new approach is to install line arresters on structures without overhead shield wires. Line arresters are surge arresters applied in parallel with the insulator string. This new line arrester technology was tested by installing nearly 1200 arresters in the Saint John area. This paper described the reasons for choosing line arresters over shield wires and presented the methods of installation. The problems and failure rates of the installed line arresters were presented along with solutions, including solutions to protect lines against lightning in areas with heavy icing. Recommendations for future research into the use, application and development of line arresters were also presented. tabs., figs.

  18. A Voice Operated Tour Planning System for Autonomous Mobile Robots

    Directory of Open Access Journals (Sweden)

    Charles V. Smith Iii

    2010-06-01

    Full Text Available Control systems driven by voice recognition software have been implemented before but lacked the context driven approach to generate relevant responses and actions. A partially voice activated control system for mobile robotics is presented that allows an autonomous robot to interact with people and the environment in a meaningful way, while dynamically creating customized tours. Many existing control systems also require substantial training for voice application. The system proposed requires little to no training and is adaptable to chaotic environments. The traversable area is mapped once and from that map a fully customized route is generated to the user

  19. A multicarrier TDM transmission system for DBS-A

    Science.gov (United States)

    Campanella, S. J.

    1992-03-01

    Satellite communications service for space based broadcasting has been suggested by the National Research Council's Technical Operation's Committee for the Voice of America. The service is referred to as direct broadcast from space-audio (DBS-A). This paper presents a concept incorporating low bit rate source coding for voice and music, digital modulation, forward error correction coding and Viterbi decoding, multiple satellite beams, and multiple carrier time division multiplexed (TDM) transmission to provide a system capable of world wide coverage. The system provides the capability to narrow cast to specific geographically clustered audiences. Emphasis is on the space segment (transmitter) and earth segment (receiver) using the techniques mentioned above.

  20. Internet-Based System for Voice Communication With the ISS

    Science.gov (United States)

    Chamberlain, James; Myers, Gerry; Clem, David; Speir, Terri

    2005-01-01

    The Internet Voice Distribution System (IVoDS) is a voice-communication system that comprises mainly computer hardware and software. The IVoDS was developed to supplement and eventually replace the Enhanced Voice Distribution System (EVoDS), which, heretofore, has constituted the terrestrial subsystem of a system for voice communications among crewmembers of the International Space Station (ISS), workers at the Payloads Operations Center at Marshall Space Flight Center, principal investigators at diverse locations who are responsible for specific payloads, and others. The IVoDS utilizes a communication infrastructure of NASA and NASArelated intranets in addition to, as its name suggests, the Internet. Whereas the EVoDS utilizes traditional circuitswitched telephony, the IVoDS is a packet-data system that utilizes a voice over Internet protocol (VOIP). Relative to the EVoDS, the IVoDS offers advantages of greater flexibility and lower cost for expansion and reconfiguration. The IVoDS is an extended version of a commercial Internet-based voice conferencing system that enables each user to participate in only one conference at a time. In the IVoDS, a user can receive audio from as many as eight conferences simultaneously while sending audio to one of them. The IVoDS also incorporates administrative controls, beyond those of the commercial system, that provide greater security and control of the capabilities and authorizations for talking and listening afforded to each user.

  1. Voice-Controlled Artificial Handspeak System

    Directory of Open Access Journals (Sweden)

    Carlo Fonda

    2014-01-01

    Full Text Available A man-machine interaction project is described which aims to establish an automated voice to sign language translator for communication with the deaf using integrated open technologies. The first prototype consists of a robotic hand designed with OpenSCAD and manufactured with a low-cost 3D printer ─which smoothly reproduces the alphabet of the sign language controlled by voice only. The core automation comprises an Arduino UNO controller used to activate a set of servo motors that follow instructions from a Raspberry Pi mini-computer having installed the open source speech recognition engine Julius. We discuss its features, limitations and possible future developments.

  2. EXPERIMENTAL STUDY OF FIRMWARE FOR INPUT AND EXTRACTION OF USER’S VOICE SIGNAL IN VOICE AUTHENTICATION SYSTEMS

    Directory of Open Access Journals (Sweden)

    O. N. Faizulaieva

    2014-09-01

    Full Text Available Scientific task for improving the signal-to-noise ratio for user’s voice signal in computer systems and networks during the process of user’s voice authentication is considered. The object of study is the process of input and extraction of the voice signal of authentication system user in computer systems and networks. Methods and means for input and extraction of the voice signal on the background of external interference signals are investigated. Ways for quality improving of the user’s voice signal in systems of voice authentication are investigated experimentally. Firmware means for experimental unit of input and extraction of the user’s voice signal against external interference influence are considered. As modern computer means, including mobile, have two-channel audio card, two microphones are used in the voice signal input. The distance between sonic-wave sensors is 20 mm and it provides forming one direction pattern lobe of microphone array in a desired area of voice signal registration (from 100 Hz to 8 kHz. According to the results of experimental studies, the usage of directional properties of the proposed microphone array and space-time processing of the recorded signals with implementation of constant and adaptive weighting factors has made it possible to reduce considerably the influence of interference signals. The results of firmware experimental studies for input and extraction of the user’s voice signal against external interference influence are shown. The proposed solutions will give the possibility to improve the value of the signal/noise ratio of the useful signals recorded up to 20 dB under the influence of external interference signals in the frequency range from 4 to 8 kHz. The results may be useful to specialists working in the field of voice recognition and speaker discrimination.

  3. Voice-Controlled Artificial Handspeak System

    Directory of Open Access Journals (Sweden)

    Jonathan Gatti

    2014-04-01

    Full Text Available A man-machine interaction project is described whic h aims to establish an automated voice to sign language translator for communication with the deaf using integrated open technologies. The first prototype consists of a robotic hand designed with OpenSCAD and manufactured with a low-cost 3D printer which smoothly reproduces the alphabet of the sign language controlled by voice only. The core automation comprises an Arduino UNO controller used to activate a set of servo motors that follow instructions from a Raspberry Pi mini-computer havi ng installed the open source speech recognition eng ine Julius. We discuss its features, limitations and po ssible future developmen

  4. Controlling An Electric Car Starter System Through Voice

    Directory of Open Access Journals (Sweden)

    A.B. Muhammad Firdaus

    2015-04-01

    Full Text Available Abstract These days automotive has turned into a stand out amongst the most well-known modes of transportation on the grounds that a large number of Malaysians could bear to have an auto. There are numerous decisions of innovations in auto that have in the market. One of the engineering is voice controlled framework. Voice Recognition is the procedure of consequently perceiving a certain statement talked by a specific speaker focused around individual data included in discourse waves. This paper is to make an car controlled by voice of human. An essential pre-processing venture in Voice Recognition systems is to recognize the vicinity of noise. Sensitivity to speech variability lacking recognition precision and helplessness to mimic are among the principle specialized obstacles that keep the far reaching selection of speech-based recognition systems. Voice recognition systems work sensibly well with a quiet conditions however inadequately under loud conditions or in twisted channels. The key focus of the project is to control an electric car starter system.

  5. A new VOX technique for reducing noise in voice communication systems. [voice operated keying

    Science.gov (United States)

    Morris, C. F.; Morgan, W. C.; Shack, P. E.

    1974-01-01

    A VOX technique for reducing noise in voice communication systems is described which is based on the separation of voice signals into contiguous frequency-band components with the aid of an adaptive VOX in each band. It is shown that this processing scheme can effectively reduce both wideband and narrowband quasi-periodic noise since the threshold levels readjust themselves to suppress noise that exceeds speech components in each band. Results are reported for tests of the adaptive VOX, and it is noted that improvements can still be made in such areas as the elimination of noise pulses, phoneme reproduction at high-noise levels, and the elimination of distortion introduced by phase delay.

  6. IBM Voice Conversion Systems for 2007 TC-STAR Evaluation

    Institute of Scientific and Technical Information of China (English)

    SHUANG Zhiwei; Raimo Bakis; QIN Yong

    2008-01-01

    This paper proposes a novel voice conversion method by frequency warping.The frequency warp-ing function is generated based on mapping formants of the source speaker and the target speaker.In addi-tion to frequency warping,fundamental frequency adjustment,spectral envelope equalization,breathiness addition,and duration modification are also used to improve the similarity to the target speaker.The pro-posed voice conversion method needs only a very small amount of training data for generating the warping function,thereby greatly facilitating its application.Systems based on the proposed method were used for the 2007 TC-STAR intra-lingual voice conversion evaluation for English and Spanish and a cross-lingual voice conversion evaluation for Spanish.The evaluation results show that the proposed method can achieve a much better quality of converted speech than other methods as well as a good balance between quality and similarity.The IBM1 system was ranked No.1 for English evaluation and No.2 for Spanish evaluation.Evaluation results also show that the proposed method is a convenient and competitive method for cross-lingual voice conversion tasks.

  7. Hybrid-Vehicle Transmission System

    Science.gov (United States)

    Lupo, G.; Dotti, G.

    1985-01-01

    Continuously-variable transmission system for hybrid vehicles couples internal-combustion engine and electric motor section, either individually or in parallel, to power vehicle wheels during steering and braking.

  8. Hybrid-Vehicle Transmission System

    Science.gov (United States)

    Lupo, G.; Dotti, G.

    1985-01-01

    Continuously-variable transmission system for hybrid vehicles couples internal-combustion engine and electric motor section, either individually or in parallel, to power vehicle wheels during steering and braking.

  9. A singing voices synthesis system to characterize vocal registers using ARX-LF model

    OpenAIRE

    Motoda, Hiroki; Akagi, Masato

    2013-01-01

    This paper proposes a singing voices synthesis system to synthesize singing voices having characteristics of vocal registers, such as vocal fly, modal and falsetto. Human can sing songs naturally in wide range of frequency by training how to use vocal fold vibrations to represent vocal registers. However, even state-of-the-art singing voices synthesis systems cannot produce vocal registers appropriately. Naturalness of the synthesized singing voices using these systems is reduced in low and h...

  10. Adaptive Multiplexing Scheme for Voice Flow Transmission Across Best-Effort IP Networks

    OpenAIRE

    Trad, Abdelbasset; Afifi, Hossam

    2003-01-01

    We investigate the performance limitations in the case of a large number of long distance voice over IP calls originating from different sources and transported through a best-effort IP network. We focus on the potentially negative effects of total protocol header overhead, which is twice the voice payload generated by the high-compression audio codecs. These negative effects range from the inefficient use of bandwidth to the network congestion caused by the large number of short voice packet...

  11. Improving speech intelligibility for binaural voice transmission under disturbing noise and reverberation using virtual speaker lateralization

    Directory of Open Access Journals (Sweden)

    A.L. Padilla Ortiz

    2015-06-01

    Full Text Available Subjective speech intelligibility tests were carried out in order to investigate strategies to improve speech intelligibility in binaural voice transmission when listening from different azimuth angles under adverse listening conditions. Phonetically balanced bi-syllable meaningful words in Spanish were used as speech material. The speech signal was played back through headphones, undisturbed, and also with the addition of high levels of disturbing noise or reverberation, with a signal to noise ratio of SNR = –10 dB and a reverberation time of T60 = 10 s. Speech samples were contaminated with interaurally uncorrelated noise and interaurally correlated reverberation, which previous studies have shown the more adverse. Results show that, for speech contaminated with interaurally uncorrelated noise, intelligibility scores improve for azimuth angles around ±30° over speech intelligibility at 0°. On the other hand, for interaurally correlated reverberation, binaural speech intelligibility reduces when listening at azimuth angles around ±30°, in comparison with listening at 0° or azimuth angles around ±60°.

  12. Voice and GPS Based Navigation System For Visually Impaired

    Directory of Open Access Journals (Sweden)

    Harsha Gawari

    2014-04-01

    Full Text Available The paper represents the architecture and implementation of a system that will help to navigate the visually impaired people. The system designed uses GPS and voice recognition along with obstacle avoidance for the purpose of guiding visually impaired. The visually impaired person issues the command and receives the direction response using audio signals. The latitude and longitude values are received continuously from the GPS receiver. The directions are given to the user with the help of audio signals. An obstacle detector is used to help the user to avoid obstacles by sending an audio message.GPS receivers use NMEA standard. With the advancement in voice recognition it becomes easier to issue commands regarding directions to the visually impaired.

  13. Smart Homes with Voice Activated Systems for Disabled People

    Directory of Open Access Journals (Sweden)

    Bekir Busatlic

    2017-02-01

    Full Text Available Smart home refers to the application of various technologies to semi-unsupervised home control It refers to systems that control temperature, lighting, door locks, windows and many other appliances. The aim of this study was to design a system that will use existing technology to showcase how it can benefit people with disabilities. This work uses only off-the-shelf products (smart home devices and controllers, speech recognition technology, open-source code libraries. The Voice Activated Smart Home application was developed to demonstrate online grocery shopping and home control using voice comments and tested by measuring its effectiveness in performing tasks as well as its efficiency in recognizing user speech input.

  14. Voice Technology Design Guides for Navy Training Systems.

    Science.gov (United States)

    1983-03-01

    81 mi4000111 b bleck ehm ~m) - This project was directed toward gathering information about applications of automated speech technology (AST) and...environmental events. automated performance measurement, and a strong voice interaction between the trainee and the system. Both successes and difficulties have...80-C-0057-1 Strong interaction with the user community is necessary throughout the curriculum development. A subject matter expert, ideally, should

  15. The design of a digital voice data compression technique for orbiter voice channels

    Science.gov (United States)

    1975-01-01

    Voice bandwidth compression techniques were investigated to anticipate link margin difficulties in the shuttle S-band communication system. It was felt that by reducing the data rate on each voice channel from the baseline 24 (or 32) Kbps to 8 Kbps, additional margin could be obtained. The feasibility of such an alternate voice transmission system was studied. Several factors of prime importance that were addressed are: (1) achieving high quality voice at 8 Kbps; (2) performance in the presence of the anticipated shuttle cabin environmental noise; (3) performance in the presence of the anticipated channel error statistics; and (4) minimal increase in size, weight, and power over the current baseline voice processor.

  16. Interactive Voice/Web Response System in clinical research.

    Science.gov (United States)

    Ruikar, Vrishabhsagar

    2016-01-01

    Emerging technologies in computer and telecommunication industry has eased the access to computer through telephone. An Interactive Voice/Web Response System (IxRS) is one of the user friendly systems for end users, with complex and tailored programs at its backend. The backend programs are specially tailored for easy understanding of users. Clinical research industry has experienced revolution in methodologies of data capture with time. Different systems have evolved toward emerging modern technologies and tools in couple of decades from past, for example, Electronic Data Capture, IxRS, electronic patient reported outcomes, etc.

  17. Voice Interactive Systems Technology (VIST) Research.

    Science.gov (United States)

    1984-01-01

    Z ’-’,- FIN J. , F: .J. *. I.1. ~ ~UNCLASSIFIED S;ECURITY CLASSIFICATION OF THIS PAGE...Ground DEC PDP-11 /45 SYSTEM GEERATION INFORMiTION RSX-11M Operating System Initializat ion Command File: File Name: INIT7.CMD Contents: SET/SPEED=TT7...34 " • - - - ’ ’ v " ’ ’ .- ’ % ’ - * ’ k’" ’ " ’ ’ ’ *. , , ,", . . . . .- - . . , . .- ’ ." - . .- . , . % . - -,- - , z , . . . . -*. . * .* -. 4 --

  18. Multimodal user input to supervisory control systems - Voice-augmented keyboard

    Science.gov (United States)

    Mitchell, Christine M.; Forren, Michelle G.

    1987-01-01

    The use of a voice-augmented keyboard input modality is evaluated in a supervisory control application. An implementation of voice recognition technology in supervisory control is proposed: voice is used to request display pages, while the keyboard is used to input system reconfiguration commands. Twenty participants controlled GT-MSOCC, a high-fidelity simulation of the operator interface to a NASA ground control system, via a workstation equipped with either a single keyboard or a voice-augmented keyboard. Experimental results showed that in all cases where significant performance differences occurred, performance with the voice-augmented keyboard modality was inferior to and had greater variance than the keyboard-only modality. These results suggest that current moderately priced voice recognition systems are an inappropriate human-computer interaction technology in supervisory control systems.

  19. Human factors research problems in electronic voice warning system design

    Science.gov (United States)

    Simpson, C. A.; Williams, D. H.

    1975-01-01

    The speech messages issued by voice warning systems must be carefully designed in accordance with general principles of human decision making processes, human speech comprehension, and the conditions in which the warnings can occur. The operator's effectiveness must not be degraded by messages that are either inappropriate or difficult to comprehend. Important experimental variables include message content, linguistic redundancy, signal/noise ratio, interference with concurrent tasks, and listener expectations generated by the pragmatic or real world context in which the messages are presented.

  20. Portable EGG recording system based on a digital voice recorder.

    Science.gov (United States)

    Jang, J-K; Shieh, M-J; Kuo, T-S; Jaw, F-S

    2009-01-01

    Cutaneous electrogastrogram (EGG) recording offers the benefit of non-invasive gastrointestinal diagnosis. With long-term ambulatory recording of signals, researchers and clinicians could have more opportunities to investigate and analyse paroxysmal or acute symptoms. A portable EGG system based on a digital voice recorder (DVR) is designed for long-term recording of cutaneous EGG signals. The system consists of electrodes, an EGG amplifier, a modulator, and a DVR. Online monitoring and off-line acquisition of EGG are handled by software. A special design employing an integrated timer circuit is used to modulate the EGG frequency to meet the input requirements of the DVR. This approach involves low supply voltage and low power consumption. Software demodulation is used to simplify the complexity of the system, and is helpful in reducing the size of the portable device. By using surface-mount devices (SMD) and a low-power design, the system is robust, compact, and suitable for long-term portable recording. As a result, researchers can record an ambulatory EGG signal by means of the proposed circuits in conjunction with an up-to-date voice-recording device.

  1. Transmission system planning in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Barrie, D.; Macedo, F.X.; Mcconnach, J.S. [Ontario Hydro, Toronto, ON (Canada)

    1994-12-31

    In recent years, new and modified approaches to planning the large transmission system that serves the province of Ontario, Canada, have been necessary to accommodate the rapidly changing planning environment including slower uncertain growth, ageing of facilities, integration of demand side management and non utility generation options, increased competitiveness, increased financial stresses and affordable constraints. This paper describes some of the new and modified approaches and tools that have been adopted or are being developed by Ontario Hydro to cope with this changing environment. (author) 9 refs., 4 figs.

  2. VIDEO TRANSMISSION SYSTEM IN ITV APPLICATION

    Institute of Scientific and Technical Information of China (English)

    WangYancai; WangQunwei; WangZhaohui

    1996-01-01

    The transmission characteristics of video transmission mediums,coaxial cable and optical fiber ,are discussed in the paper. The formulas for frequency bandwidthare given to evaluate the video transmission distance. For typical video transmissionsystems with BB/IM and PFM/IM using optical fiber as the channel, expressions andcalculating results for both SIN and sensitivity are given. Finally. the principle for selecting different type of transmission systems according to transmission distances of the industrial TV is presented.

  3. 49 CFR 191.13 - Distribution systems reporting transmission pipelines; transmission or gathering systems...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution systems reporting transmission pipelines; transmission or gathering systems reporting distribution pipelines. 191.13 Section 191.13... Distribution systems reporting transmission pipelines; transmission or gathering systems reporting...

  4. Fractional Frequency Transmission System and Its Applications

    Institute of Scientific and Technical Information of China (English)

    WANG Xifan; WANG Xiuli; TENG Yufei

    2012-01-01

    In 1994, we proposed transmission approach, the a novel fractional electricity frequency transmission system (FFTS), which uses lower frequency (50/3 Hz) to reduce the electrical length of AC power lines and thus obviously increases transmission capacity. The system is especially suitable to transmit remote renewable power such as hydro power and wind power.

  5. Evaluation of voice codecs for the Australian mobile satellite system

    Science.gov (United States)

    Bundrock, Tony; Wilkinson, Mal

    1990-01-01

    The evaluation procedure to choose a low bit rate voice coding algorithm is described for the Australian land mobile satellite system. The procedure is designed to assess both the inherent quality of the codec under 'normal' conditions and its robustness under 'severe' conditions. For the assessment, normal conditions were chosen to be random bit error rate with added background acoustic noise and the severe condition is designed to represent burst error conditions when mobile satellite channel suffers from signal fading due to roadside vegetation. The assessment is divided into two phases. First, a reduced set of conditions is used to determine a short list of candidate codecs for more extensive testing in the second phase. The first phase conditions include quality and robustness and codecs are ranked with a 60:40 weighting on the two. Second, the short listed codecs are assessed over a range of input voice levels, BERs, background noise conditions, and burst error distributions. Assessment is by subjective rating on a five level opinion scale and all results are then used to derive a weighted Mean Opinion Score using appropriate weights for each of the test conditions.

  6. Perceptual Evaluation Of Playout Buffer Algorithm For Enhancing Perceived Quality Of Voice Transmission Over Ip Network

    CERN Document Server

    Perwej, Yusuf; 10.5121/ijmnct.2012.2201

    2012-01-01

    Voice over Internet Protocol (VoIP) is a technology that allows you to make voice calls using a broadband Internet connection instead of a regular (or analog) phone line. Voice over Internet Protocol (VoIP) has led human speech to a new level, where conversation across continents can be much cheaper & faster. However, as IP networks are not designed for real-time applications, the network impairments such as packet loss, jitter and delay have a severe impact on speech quality. The playout buffer at the receiver side is used to compensate jitter at a trade-off of delay and loss. We found the characteristics of delay and loss are dependent on IP network and sudden variable delay (spike) often performs both regular and irregular characteristics. Different playout buffer algorithms can have different impacts on the achievement speech quality. It is important to design a playout buffer algorithm which can help achieve an optimum speech quality. In this paper, we investigate to the understanding how network imp...

  7. RESEARCH OF DYNAMIC CHARACTERIATIC FOR TRANSMISSION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The kinetic precision of transmission chain is a key problem in the research of gear cutting machine transmission system.The traditional point of view is to consider the transmission chain as a geometrical meshing system,thus it is deemed that the kinetic precision of the transmission chain only depends on the manufacturing and assembly errors of its transmission parts.But further research reveals that the kinetic precision of transmission system is closely related with the system dynamic effects.Therefore,from the dynamic point of view,it is discerned that not only deems the transmission chain as a geometrical meshing system but also considers it as a dynamic system performing with torsional vibration.On the basis of analyses and processes of measuring data of samples from tests of cutting machine's kinetic precision of transmission chain,the results represent that the influences of dynamic characteristics of the transmission system on its kinetic precision is non-negligible.Experimental methods for discerning the transfer function of torsional vibration of gear transmission system and experimental results have been given.

  8. Voice Quality Estimation in Combined Radio-VoIP Networks for Dispatching Systems

    Directory of Open Access Journals (Sweden)

    Jiri Vodrazka

    2016-01-01

    Full Text Available The voice quality modelling assessment and planning field is deeply and widely theoretically and practically mastered for common voice communication systems, especially for the public fixed and mobile telephone networks including Next Generation Networks (NGN - internet protocol based networks. This article seeks to contribute voice quality modelling assessment and planning for dispatching communication systems based on Internet Protocol (IP and private radio networks. The network plan, correction in E-model calculation and default values for the model are presented and discussed.

  9. Remote capture of human voice acoustical data by telephone: A methods study

    OpenAIRE

    Cannizzaro, Michael S.; Reilly, Nicole; Mundt, James C.; Snyder, Peter J.

    2005-01-01

    In this pilot study we sought to determine the reliability and validity of collecting speech and voice acoustical data via telephone transmission for possible future use in large clinical trials. Simultaneous recordings of each participant's speech and voice were made at the point of participation, the local recording (LR), and over a telephone line using a dedicated in-line computerized interactive voice recording system, the remote recording (RR). All voice recordings were made from our lab...

  10. A Dependence between Average Call Duration and Voice Transmission Quality: Measurement and applications

    NARCIS (Netherlands)

    Holub, J.; Beerends, J.G.; Smid, R.

    2004-01-01

    This contribution deals with the estimation of the relation between speech transmission quality and average call duration for a given network and portfolio of customers. It uses non-intrusive speech quality measurements on live speech calls. The basic idea behind this analysis is an expectation that

  11. A Dependence between Average Call Duration and Voice Transmission Quality: Measurement and applications

    NARCIS (Netherlands)

    Holub, J.; Beerends, J.G.; Smid, R.

    2004-01-01

    This contribution deals with the estimation of the relation between speech transmission quality and average call duration for a given network and portfolio of customers. It uses non-intrusive speech quality measurements on live speech calls. The basic idea behind this analysis is an expectation that

  12. Gear Transmission Error Measurement System Made Operational

    Science.gov (United States)

    Oswald, Fred B.

    2002-01-01

    A system directly measuring the transmission error between the meshing spur or helical gears was installed at the NASA Glenn Research Center and made operational in August 2001. This system employs light beams directed by lenses and prisms through gratings mounted on the two gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. The device is capable of resolution better than 0.1 mm (one thousandth the thickness of a human hair). The measured transmission error can be displayed in a "map" that shows how the transmission error varies with the gear rotation or it can be converted to spectra to show the components at the meshing frequencies. Accurate transmission error data will help researchers better understand the mechanisms that cause gear noise and vibration and will lead to The Design Unit at the University of Newcastle in England specifically designed the new system for NASA. It is the only device in the United States that can measure dynamic transmission error at high rotational speeds. The new system will be used to develop new techniques to reduce dynamic transmission error along with the resulting noise and vibration of aeronautical transmissions.

  13. Multi-modal assessment of on-road demand of voice and manual phone calling and voice navigation entry across two embedded vehicle systems.

    Science.gov (United States)

    Mehler, Bruce; Kidd, David; Reimer, Bryan; Reagan, Ian; Dobres, Jonathan; McCartt, Anne

    2016-03-01

    One purpose of integrating voice interfaces into embedded vehicle systems is to reduce drivers' visual and manual distractions with 'infotainment' technologies. However, there is scant research on actual benefits in production vehicles or how different interface designs affect attentional demands. Driving performance, visual engagement, and indices of workload (heart rate, skin conductance, subjective ratings) were assessed in 80 drivers randomly assigned to drive a 2013 Chevrolet Equinox or Volvo XC60. The Chevrolet MyLink system allowed completing tasks with one voice command, while the Volvo Sensus required multiple commands to navigate the menu structure. When calling a phone contact, both voice systems reduced visual demand relative to the visual-manual interfaces, with reductions for drivers in the Equinox being greater. The Equinox 'one-shot' voice command showed advantages during contact calling but had significantly higher error rates than Sensus during destination address entry. For both secondary tasks, neither voice interface entirely eliminated visual demand. Practitioner Summary: The findings reinforce the observation that most, if not all, automotive auditory-vocal interfaces are multi-modal interfaces in which the full range of potential demands (auditory, vocal, visual, manipulative, cognitive, tactile, etc.) need to be considered in developing optimal implementations and evaluating drivers' interaction with the systems. Social Media: In-vehicle voice-interfaces can reduce visual demand but do not eliminate it and all types of demand need to be taken into account in a comprehensive evaluation.

  14. Methods, apparatus, and systems for monitoring transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Polk, Robert E; Svoboda, John M.; West, Phillip B.; Heath, Gail L.; Scott, Clark L.

    2016-07-19

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  15. Multi-core fiber undersea transmission systems

    DEFF Research Database (Denmark)

    Nooruzzaman, Md; Morioka, Toshio

    2017-01-01

    Various potential architectures of branching units for multi-core fiber undersea transmission systems are presented. It is also investigated how different architectures of branching unit influence the number of fibers and those of inline components.......Various potential architectures of branching units for multi-core fiber undersea transmission systems are presented. It is also investigated how different architectures of branching unit influence the number of fibers and those of inline components....

  16. Harmonics in transmission power systems

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz

    to perform more detailed harmonic studies emerged. Since the transmission network has a complex structure and its impedance varies with frequency in a nonlinear fashion, such harmonic study would require a detailed computer model of the network. Consequently, a PhD project proposal titled "Harmonics....... It is concluded that since some background harmonic distortion is practically always present in the network, a method based on variation of harmonic values must be used. The incremental values of harmonic distortion will allow to verify the harmonic model, despite the existence of background harmonic distortion...... GPS-synchronized OMICRON CMC256 units. Two such units are installed at 400 kV substations at both ends of the disconnected line and a third unit is located at a substation in a distance of 80 km. Time domain "snap-shot" measurements of three-phase voltages and currents are synchronously taken for some...

  17. APEnet+ 34 Gbps data transmission system and custom transmission logic

    Science.gov (United States)

    Ammendola, R.; Biagioni, A.; Frezza, O.; Lonardo, A.; Lo Cicero, F.; Paolucci, P. S.; Rossetti, D.; Simula, F.; Tosoratto, L.; Vicini, P.

    2013-12-01

    APEnet+ is a point-to-point, low-latency, 3D-torus network controller integrated in a PCIe Gen2 board based on the Altera Stratix IV FPGA. We characterize the transmission system (embedded transceivers driving external QSFP+ modules) analyzing signal integrity, throughput, latency, BER and jitter at different data rates up to 34 Gbps. We estimate the efficiency of a custom logic able to sustain 2.6 GB/s per link with an FPGA on-chip memory footprint of 40 KB, providing deadlock-free routing and systemic awareness of faults. Finally, we show the preliminary results obtained with the embedded transceivers of a next-generation FPGA and outline some ideas to increase the performance with the same FPGA memory footprint.

  18. Exploring the anatomical encoding of voice with a mathematical model of the vocal system.

    Science.gov (United States)

    Assaneo, M Florencia; Sitt, Jacobo; Varoquaux, Gael; Sigman, Mariano; Cohen, Laurent; Trevisan, Marcos A

    2016-11-01

    The faculty of language depends on the interplay between the production and perception of speech sounds. A relevant open question is whether the dimensions that organize voice perception in the brain are acoustical or depend on properties of the vocal system that produced it. One of the main empirical difficulties in answering this question is to generate sounds that vary along a continuum according to the anatomical properties the vocal apparatus that produced them. Here we use a mathematical model that offers the unique possibility of synthesizing vocal sounds by controlling a small set of anatomically based parameters. In a first stage the quality of the synthetic voice was evaluated. Using specific time traces for sub-glottal pressure and tension of the vocal folds, the synthetic voices generated perceptual responses, which are indistinguishable from those of real speech. The synthesizer was then used to investigate how the auditory cortex responds to the perception of voice depending on the anatomy of the vocal apparatus. Our fMRI results show that sounds are perceived as human vocalizations when produced by a vocal system that follows a simple relationship between the size of the vocal folds and the vocal tract. We found that these anatomical parameters encode the perceptual vocal identity (male, female, child) and show that the brain areas that respond to human speech also encode vocal identity. On the basis of these results, we propose that this low-dimensional model of the vocal system is capable of generating realistic voices and represents a novel tool to explore the voice perception with a precise control of the anatomical variables that generate speech. Furthermore, the model provides an explanation of how auditory cortices encode voices in terms of the anatomical parameters of the vocal system.

  19. 基于ARM的嵌入式语音存储系统设计%Design of Embedded Voice Storage System Based on ARM

    Institute of Scientific and Technical Information of China (English)

    于春雪

    2012-01-01

    In order to effectively save the transmission bandwidth of voice data and disk space of storage system, it needs to lower the encoding bit rate when ensuring the voice quality. The design uses optimized G. 729 voice compression encoding and decoding algorithm and ARM processor. The embedded voice storage systems can achieve mass storage of voice signals. It has fast processing speed, good reliability and convenient expansion. Through rigorous test and evaluation, the system achieves the compression and recording of large num- bers of voice data,and indicators reachs the expected level.%为了有效地节省语音数据的传输带宽和存储系统的磁盘空间,需要在保证语音质量的前提下尽可能降低其编码比特率。本设计采用经过优化的G.729语音压缩编译码算法,以ARM处理器为载体,开发的嵌入式语音存储系统可实现语音信号的海量存储,而且处理速度快、可靠性好、扩展方便。通过严格的测试和评估,该系统能够实现对大量语音数据的压缩和记录,各项指标基本达到了预期的水平。

  20. Motorcycle Start-stop System based on Intelligent Biometric Voice Recognition

    Science.gov (United States)

    Winda, A.; E Byan, W. R.; Sofyan; Armansyah; Zariantin, D. L.; Josep, B. G.

    2017-03-01

    Current mechanical key in the motorcycle is prone to bulgary, being stolen or misplaced. Intelligent biometric voice recognition as means to replace this mechanism is proposed as an alternative. The proposed system will decide whether the voice is belong to the user or not and the word utter by the user is ‘On’ or ‘Off’. The decision voice will be sent to Arduino in order to start or stop the engine. The recorded voice is processed in order to get some features which later be used as input to the proposed system. The Mel-Frequency Ceptral Coefficient (MFCC) is adopted as a feature extraction technique. The extracted feature is the used as input to the SVM-based identifier. Experimental results confirm the effectiveness of the proposed intelligent voice recognition and word recognition system. It show that the proposed method produces a good training and testing accuracy, 99.31% and 99.43%, respectively. Moreover, the proposed system shows the performance of false rejection rate (FRR) and false acceptance rate (FAR) accuracy of 0.18% and 17.58%, respectively. In the intelligent word recognition shows that the training and testing accuracy are 100% and 96.3%, respectively.

  1. DLMS Voice Data Entry.

    Science.gov (United States)

    1980-06-01

    between operator and computer displayed on ADM-3A 20c A-I Possible Hardware Configuration for a Multistation Cartographic VDES ...this program a Voice Recognition System (VRS) which can be used to explore the use of voice data entry ( VDE ) in the DIMS or other cartographic data...Multi-Station Cartographic Voice Data Entry System An engineering development model voice data entry system ( VDES ) could be most efficiently

  2. Penguins use the two-voice system to recognize each other.

    Science.gov (United States)

    Aubin, T; Jouventin, P; Hildebrand, C

    2000-06-07

    The sound-producing structure in birds is the syrinx, which is usually a two-part organ located at the junction of the bronchi. As each branch of the syrinx produces sound independently, many birds have two acoustic sources. Thirty years ago, we had anatomical, physiological and acoustical evidence of this two-voice phenomenon but no function was known. In songbirds, often these two voices with their respective harmonics are not activated simultaneously but they are obvious in large penguins and generate a beat pattern which varies between individuals. The emperor penguin breeds during the Antarctic winter, incubating and carrying its egg on its feet. Without the topographical cue of a nest, birds identify each other only by vocal means when switching duties during incubation or chick rearing. To test whether the two-voice system contains the identity code, we played back the modified call of their mate to both adults and also the modified call of their parents to chicks. Both the adults and the chicks replied to controls (two voices) but not to modified signals (one voice being experimentally suppressed). Our experiments demonstrate that the beat generated by the interaction of these two fundamental frequencies conveys information about individual identity and also propagates well through obstacles, being robust to sound degradation through the medium of bodies in a penguin colony. The two-voice structure is also clear in the call of other birds such as the king penguin, another non-nesting species, but not in the 14 other nesting penguins. We concluded that the two-voice phenomenon functions as an individual recognition system in species using few if any landmarks to meet. In penguins, this coding process, increasing the call complexity and resisting sound degradation, has evolved in parallel with the loss of territoriality.

  3. Phonological systems of pediatric cochlear implant users: The acquisition of voicing

    Science.gov (United States)

    Chin, Steven B.; Oglesbee, Eric N.; Kirk, Andrew K.; Krug, Joseph E.

    2005-04-01

    Although cochlear implants are primarily auditory prostheses, they have also demonstrated their usefulness as aids to speech production and the acquisition of spoken language in children. This presentation reports on research currently being conducted at the Indiana University Medical Center on the development of phonological systems by children with five or more years of cochlear implant use in English-speaking environments. Characteristics of the feature [voice] will be examined in children with cochlear implants and in two comparison groups: adults with normal hearing and children with normal hearing. Specific aspects of voicing to be discussed include characteristic error patterns, phonetic implementation of the voicing contrast, and phonetic implementation of neutralization of the voicing contrast. Much of the evidence obtained thus far indicates that voicing acquisition in children with cochlear implants is not radically different from that of children with normal hearing. Many differences between the systems of children with cochlear implants and the ambient system thus appear to reflect the children's age as much as their hearing status. [Work supported by grants from the National Institutes of Health to Indiana University: R01DC005594 and R03DC003852.

  4. Economics Of Optical Fibre Transmission Systems

    Science.gov (United States)

    Murray, W. J.

    1983-08-01

    Optical fibre as a telecommunication transmission medium has become one of the most significant developments so far of the digital era. A major contributory factor to the availability of optical fibre transmission systems has been the outstanding progress in the technology of manufacturing high quality glass fibre having relatively low attenuation and broad bandwidths. This and other achievements has enabled manufacturers in the United Kingdom to develop a range of optical fibre cables and transmission equipment for operation over short and long distances at the CCITT recommended digital hierarchical rates of 2, 8, 34 and 140Mbit/s which have been adopted by British Telecom (BT) for modernisation to an all digital transmission network. These optical fibre systems are now becoming increasingly price and performance competitive with conventional technology in many parts of telecommunications networks. In the British Telecom (BT) network the 140Mbit/s optical fibre systems are now economically competitive with equivalent systems on coaxial cable and microwave radio. The economics of 8 and 34Mbit/s systems are not yet sufficiently attractive, compared with 2Mbit/s digital line systems on pair type copper cables, for large scale use in rural and local distribution networks and are presently only justified on cost in and around large cities. As system costs decrease large applications are predicted particularly in support of future high speed data, cable television and visual information services.

  5. New Gear Transmission Error Measurement System Designed

    Science.gov (United States)

    Oswald, Fred B.

    2001-01-01

    The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.

  6. 75 FR 41509 - Notice of Proposed Information Collection for Public Comment; LOCCS Voice Response System Payment...

    Science.gov (United States)

    2010-07-16

    ... System Payment Vouchers for Public and Indian Housing Programs AGENCY: Office of the Assistant Secretary... Payment Vouchers for Public and Indian Housing Programs. OMB Control Number: 2577-0166. Agency form number... voice activated system. The information collected on the payment voucher will also be used as...

  7. MDP-based resource allocation for triple-play transmission on xDSL systems

    Science.gov (United States)

    de Souza, Lamartine V.; de Carvalho, Glaucio H. S.; Cardoso, Diego L.; de Carvalho, Solon V.; Frances, Carlos R. L.; Costa, João C. W. A.; Riu, Jaume Rius i.

    2007-09-01

    Many broadband services are based on multimedia applications, such as voice over internet protocol (VoIP), video conferencing, video on demand (VoD), and internet protocol television (IPTV). The combination "triple-play" is often used with IPTV. It simply means offering voice, video and data. IPTV and others services uses digital broadband networks such as ADSL2+ (Asymmetric Digital Subscriber Line) and VDSL (Very High Rate DSL) to transmit the data. We have formulated a MDP (Markov Decision Process) for a triple-play transmission on DSL environment. In this paper, we establish the relationship between DSL transmission characteristics and its finite-state Markov model for a triple-play transmission system. This relationship can be used for a resource management for multimedia applications delivered through a broadband infrastructure. The solution to our optimization problem can be found using dynamic programming (DP) techniques, such as value iteration and its variants. Our study results in a transmission strategy that chooses the optimal resource allocation according the triple-play traffic requirements, defined in technical report TR-126 (Triple-Play Services Quality of Experience Requirements) from DSL Forum, minimizing quality of service (QoS) violations with respect to bandwidth. Three traffic classes (video, audio, and best effort internet data) are defined and analyzed. Our simulation results show parameters like as blocking probability for each class, link utilization and optimal control policies. The MDP-based approach provides a satisfactory way of resource management for a DSL system.

  8. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...

  9. Benchmarking European Gas Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter; Trinkner, Urs

    This is the final report for the pan-European efficiency benchmarking of gas transmission system operations commissioned by the Netherlands Authority for Consumers and Markets (ACM), Den Haag, on behalf of the Council of European Energy Regulators (CEER) under the supervision of the authors....

  10. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...

  11. Benchmarking European Gas Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter; Trinkner, Urs

    This is the final report for the pan-European efficiency benchmarking of gas transmission system operations commissioned by the Netherlands Authority for Consumers and Markets (ACM), Den Haag, on behalf of the Council of European Energy Regulators (CEER) under the supervision of the authors....

  12. Wireless Transmission System for Vehicle Inspection Data

    Institute of Scientific and Technical Information of China (English)

    LIU Yuan; MIAO Chang-yun

    2008-01-01

    Based on general packet radio service(GPRS) and TCP/IP protocol, a wireless transmission system of vehicle inspection data is designed. Basic structure and work theory are expounded. SIM300 designed by SIMCOM is used for client GPRS communication module. Using Winsock control of visual basic(VB), the client and server communication has been accomplished. By means of a client and server communications software, the remote wireless transmission of vehicle inspection data has been accomplished also. The server management software has been developed by using Microsoft SQL Server 2000 and VB6.0. Functions of software include import, inquiry, export and maintenance of test data.

  13. Self Assistive Technology for Disabled People – Voice Controlled Wheel Chair and Home Automation System

    Directory of Open Access Journals (Sweden)

    R. Puviarasi

    2014-07-01

    Full Text Available This paper describes the design of an innovative and low cost self-assistive technology that is used to facilitate the control of a wheelchair and home appliances by using advanced voice commands of the disabled people. This proposed system will provide an alternative to the physically challenged people with quadriplegics who is permanently unable to move their limbs (but who is able to speak and hear and elderly people in controlling the motion of the wheelchair and home appliances using their voices to lead an independent, confident and enjoyable life. The performance of this microcontroller based and voice integrated design is evaluated in terms of accuracy and velocity in various environments. The results show that it could be part of an assistive technology for the disabled persons without any third person’s assistance.

  14. Data Equivalency of an Interactive Voice Response System for Home Assessment of Back Pain and Function

    Directory of Open Access Journals (Sweden)

    William S Shaw

    2007-01-01

    Full Text Available BACKGROUND: Interactive voice response (IVR systems that collect survey data using automated, push-button telephone responses may be useful to monitor patients’ pain and function at home; however, its equivalency to other data collection methods has not been studied.

  15. Transmission techniques for 4G systems

    CERN Document Server

    Da Silva, Mario Marques

    2012-01-01

    Fourth Generation (4G) wireless communication systems support current and emergent multimedia services such as mobile TV, social networks and gaming, high-definition TV, video teleconferencing, and messaging services. These systems feature the All-over-IP concept and boast improved quality of service. Several important R&D activities are currently under way in the field of wireless communications for 4G systems, but the coverage is widespread in the literature. Transmission Techniques for 4G Systems presents a compilation of the latest developments in the field of wireless communications for 4

  16. The role of the medial temporal limbic system in processing emotions in voice and music.

    Science.gov (United States)

    Frühholz, Sascha; Trost, Wiebke; Grandjean, Didier

    2014-12-01

    Subcortical brain structures of the limbic system, such as the amygdala, are thought to decode the emotional value of sensory information. Recent neuroimaging studies, as well as lesion studies in patients, have shown that the amygdala is sensitive to emotions in voice and music. Similarly, the hippocampus, another part of the temporal limbic system (TLS), is responsive to vocal and musical emotions, but its specific roles in emotional processing from music and especially from voices have been largely neglected. Here we review recent research on vocal and musical emotions, and outline commonalities and differences in the neural processing of emotions in the TLS in terms of emotional valence, emotional intensity and arousal, as well as in terms of acoustic and structural features of voices and music. We summarize the findings in a neural framework including several subcortical and cortical functional pathways between the auditory system and the TLS. This framework proposes that some vocal expressions might already receive a fast emotional evaluation via a subcortical pathway to the amygdala, whereas cortical pathways to the TLS are thought to be equally used for vocal and musical emotions. While the amygdala might be specifically involved in a coarse decoding of the emotional value of voices and music, the hippocampus might process more complex vocal and musical emotions, and might have an important role especially for the decoding of musical emotions by providing memory-based and contextual associations.

  17. EasyVoice: Integrating voice synthesis with Skype

    CERN Document Server

    Condado, Paulo A

    2007-01-01

    This paper presents EasyVoice, a system that integrates voice synthesis with Skype. EasyVoice allows a person with voice disabilities to talk with another person located anywhere in the world, removing an important obstacle that affect these people during a phone or VoIP-based conversation.

  18. A Prototype System for Controlling a Computer by Head Movements and Voice Commands

    CERN Document Server

    Ismail, Anis; Hajjar, Mohammad

    2011-01-01

    This paper introduces a new prototype system for controlling a PC by head movements and also with voice commands. Our system is a multimodal interface concerned with controlling the computer. The selected modes of interaction are speech and gestures. We are seeing the revolutionary of computers and information technologies into daily practice. Healthy people use keyboard, mouse, trackball, or touchpad for controlling the PC. However these peripheries are usually not suitable for handicapped people. They may have problems using these standard peripheries, for example when they suffer from myopathy, or cannot move their hands after an injury. Our system has been developed to provide computer access for people with severe disabilities. This system tracks the computer user's Head movements with a video camera and translates them into the movements of the mouse pointer on the screen and the voice as button presses. Therefore we are coming with a proposal system that can be used with handicapped people to control t...

  19. Musicalidade e transmissao da voz: James, John e Lucia Joyce // Musicality and transmission of the voice: James, John and Lucia Joyce

    Directory of Open Access Journals (Sweden)

    Renata Mattos

    2012-06-01

    Full Text Available Este artigo tem como objetivo trabalhar a temática da voz, da música e do traço em James Joyce, seu pai John e sua filha Lucia com o intuito de pensar as diferentes saídas possíveis face à questão do sintoma da carência paterna, seja pela elevação ao sinthoma pela escrita de uma obra literária no caso de Joyce, seja pela tentativa de manejo da voz através da dança, no caso de Lucia. Propomos tomar a escrita de James Joyce naquilo que ela nos oferece para pensar a relação entre uma escrita possível da voz e a invocação ao Pai, detendo-nos na transmissão da voz efetuada nestas três gerações da família Joyce, no que cada um deles pôde, de maneiras singulares, criar face ao real. // The aim of this paper is to work the thematic of the voice, the music and the trait in James Joyce, his father John and his daughter Lucia in order to think about the question of the elevation of the symptom of the lack of the father through the writing of James Joyce in his literary work as well as though the relation of Lucia with the dance. Our proposal is to reflect about the writing of Joyce to think about the relation between a possible writing of the voice and the invocation to the Father, as well as the transmission of the voice made in these three generations of the Joyce family in what each one of them could, in different ways, create guided by the real.

  20. Semantic Model for Voice Controlled Telephone Dialing and Inquiry Systems

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A new scheme is presented to detect a large number of keywords in voice controlled switchboard tasks. The new scheme is based on two stages. In the first stage, N-best syllable candidates with their corresponding acoustic scores are generated by an acoustic recognizer. In the second stage, a semantic model based parser is applied to determine the optimum keywords by searching through the lattice of N-best candidates. The experimental results show that when the spoken input deviates from the predefined syntactic constraints, the parser can also demonstrate high performance. For comparison purposes, the most common way to incorporate the syntactic knowledge of the task directly into the acoustic recognizer in the form of a finite state network is also investigated. Furthermore, to address the sparse-data problems, out-of-domain data in the form of newspaper text are used to obtain a more robust combined semantic model. The experiments show that the combined semantic model can improve the keywords detection rate from 90.07% to 92.91% when 80 ungrammatical sentences which do not conform to the task grammar are used as testing material.

  1. VOICE ACTIVATED MULTIPROCESSOR EMBEDDED SYSTEM TO IMPROVE THE CONTROL OF A MOTORIZED WHEELCHAIR

    Directory of Open Access Journals (Sweden)

    SANGMESHWAR S. KENDRE,

    2010-11-01

    Full Text Available The main idea of this work is to process analog voice signal. The theme is implemented for controlling the wheelchair by voice through speech processing using Hawkboard (OMAP processor. The adopted model is based on grouping a ARM and a DSP processor for speech enhancement with a voice recognition module for isolated word and speaker dependent. The Texas Instruments OMAP-L138 is integrated in order to enhance the quality of speech signal by reducing noise and connected with the wheelchair for processing of the voice signal. The Hawkboard denoises speech signal and HMC2007 recognizes the commnads. It also generates different desired signals according to the spoken words which further used to control the movement of wheelchair, a vector of information on the context given by a set of sensors for security actions. Six words are recognized which are start, forward, reverse, left, right, stop. In order to gain in time design, experiments have shown that the best way is to choose a speech recognition kit and to adapt it to the application. The result at the end show the efficiency of the system.

  2. Flexible AC transmission systems modelling and control

    CERN Document Server

    Zhang, Xiao-Ping; Pal, Bikash

    2012-01-01

    The extended and revised second edition of this successful monograph presents advanced modeling, analysis and control techniques of Flexible AC Transmission Systems (FACTS). The book covers comprehensively a range of power-system control problems: from steady-state voltage and power flow control, to voltage and reactive power control, to voltage stability control, to small signal stability control using FACTS controllers. In the six years since the first edition of the book has been published research on the FACTS has continued to flourish while renewable energy has developed into a mature and

  3. Switching in electrical transmission and distribution systems

    CERN Document Server

    Smeets, René; Kapetanovic, Mirsad; Peelo, David F; Janssen, Anton

    2014-01-01

    Switching in Electrical Transmission and Distribution Systems presents the issues and technological solutions associated with switching in power systems, from medium to ultra-high voltage. The book systematically discusses the electrical aspects of switching, details the way load and fault currents are interrupted, the impact of fault currents, and compares switching equipment in particular circuit-breakers. The authors also explain all examples of practical switching phenomena by examining real measurements from switching tests. Other highlights include: up to date commentary on new develo

  4. The Study of Application System for Small and Medium CTI Based on Voice Card

    Directory of Open Access Journals (Sweden)

    Zhong Dong

    2016-01-01

    Full Text Available With the rapid development of computer telecommunications integration (CTI technology, the development of application system for small and medium CTI are updated constantly, but the study of application system for small and medium CTI, we are lack of a stability and unified model. In this paper, the author analyzes the unified structure platform of application system for small and medium CTI based on voice card. Meanwhile, the author introduces a suitable software architecture model and general procedural framework for application system for small and medium CTI based on voice card by using the idea of hierarchical design, which shows the versatility of the architecture. It provided an efficient channel for the development of small and medium CTI.

  5. Network video transmission system based on SOPC

    Science.gov (United States)

    Zhang, Zhengbing; Deng, Huiping; Xia, Zhenhua

    2008-03-01

    Video systems have been widely used in many fields such as conferences, public security, military affairs and medical treatment. With the rapid development of FPGA, SOPC has been paid great attentions in the area of image and video processing in recent years. A network video transmission system based on SOPC is proposed in this paper for the purpose of video acquisition, video encoding and network transmission. The hardware platform utilized to design the system is an SOPC board of model Altera's DE2, which includes an FPGA chip of model EP2C35F672C6, an Ethernet controller and a video I/O interface. An IP core, known as Nios II embedded processor, is used as the CPU of the system. In addition, a hardware module for format conversion of video data, and another module to realize Motion-JPEG have been designed with Verilog HDL. These two modules are attached to the Nios II processor as peripheral equipments through the Avalon bus. Simulation results show that these two modules work as expected. Uclinux including TCP/IP protocol as well as the driver of Ethernet controller is chosen as the embedded operating system and an application program scheme is proposed.

  6. Effects of emotional and perceptual-motor stress on a voice recognition system's accuracy: An applied investigation

    Science.gov (United States)

    Poock, G. K.; Martin, B. J.

    1984-02-01

    This was an applied investigation examining the ability of a speech recognition system to recognize speakers' inputs when the speakers were under different stress levels. Subjects were asked to speak to a voice recognition system under three conditions: (1) normal office environment, (2) emotional stress, and (3) perceptual-motor stress. Results indicate a definite relationship between voice recognition system performance and the type of low stress reference patterns used to achieve recognition.

  7. Hands-free speech after surgical voice rehabilitation with a Provox voice prosthesis: experience with the Provox FreeHands HME tracheostoma valve system.

    Science.gov (United States)

    Lorenz, K J; Groll, K; Ackerstaff, A H; Hilgers, F J M; Maier, H

    2007-02-01

    Excellent results have been reported with the use of voice prostheses for the rehabilitation of laryngectomees. Patients, however, consider it a disadvantage that the tracheostoma must be closed manually for speech production. This limits their ability to simultaneously communicate by gesture or to work with both hands. An automatic tracheostoma valve helps patients overcome this problem. We describe a prospective clinical trial evaluating our experience with the Provox FreeHands HME Automatic Tracheostoma Valve system. Twenty-four laryngectomees were randomly selected from the patients who had undergone laryngectomy at the ENT Department. Immediately, after 4 weeks and 6 months later having been fitted with a Provox FreeHands HME, the patients were asked to complete a questionnaire in order to assess their satisfaction, voice quality, wearing comfort, fixation, potential problems, and the effectiveness of the HME cassette. In addition, we investigated relevant voice quality parameters including dynamics range, frequency range of the speaking voice, and maximum phonation time. Seven patients discontinued the study due to problems of securing the valve to the skin (four patients) or recurrent cancer (three patients). Ten of the remaining 17 patients wore the valve daily for an average of 8.4 h. A total of 88% of the patients considered it a great advantage to be able to speak without having to use their hands. With the Provox FreeHands HME, maximum phonation time was 8.7 (+/-6.2) s and the dynamic range was 21.9 (+/-5.8) decibels. The results show that the Provox FreeHands HME Automatic Tracheostoma Valve system not only allows hands-free speech but is also associated with excellent compliance and good voice rehabilitation.

  8. The linear position tracking servo system using a linear voice-coil motor

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    More and more linear servo systems have been used in servo applications. Direct drive technology can greatly increase the bandwidth and the tracking accuracy. A position servo-system based on linear voice-coil motor was designed for one linear oscillation movement application. Besides the conventional position, speed and current control loops, the speed and acceleration feed-forward control of command position signal were also used. The experimental test proved the correctness of the design, and the system can track the given periodic sinnsoid position command signal of 15Hz with high accuracy. The linear voice-coil motor is very suitable for short stroke position tracking application with high dynamic response.

  9. Highly Efficient Contactless Electrical Energy Transmission System

    Science.gov (United States)

    Ayano, Hideki; Nagase, Hiroshi; Inaba, Hiromi

    This paper proposes a new concept for a contactless electrical energy transmission system for an elevator and an automated guided vehicle. The system has rechargeable batteries on the car and electrical energy is supplied at a specific place. When electric power is supplied to the car, it runs automatically and approaches the battery charger. Therefore, a comparatively large gap is needed between the primary transformer at the battery charger and the secondary transformer on the car in order to prevent damage which would be caused by a collision. In this case, a drop of the transformer coupling rate due to the large gap must be prevented. In conventional contactless electrical energy transmission technology, since electric power is received by a pick-up coil from a power line, a large-sized transformer is required. And when the distance over which the car runs is long, the copper loss of the line also increases. The developed system adopts a high frequency inverter using a soft switching method to miniaturize the transformer. The system has a coupling rate of 0.88 for a transformer gap length of 10mm and can operate at 91% efficiency.

  10. 47 CFR 73.6023 - Distributed transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Distributed transmission systems. 73.6023... distributed transmission system. ... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6023 Distributed...

  11. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...... TSO operating in each jurisdiction. The solution for European regulators has been found in international regulatory benchmarking, organized in collaboration with the Council of European Energy Regulators (CEER) in 2008 and 2012 for 22 and 23 TSOs, respectively. The frontier study provides static cost...... weight restrictions and a correction method for opening balances....

  12. EFFICIENT IMAGE TRANSMISSION SCHEME IN FMT SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Qi Zhongrui; Gao Zhenming

    2005-01-01

    An efficient image transmission scheme is proposed based on byte partition and adaptive sub-channel distribution technique in Filtered MultiTone (FMT) system over frequency selective slow fading channel. According to the simulation results and analysis of a typical image with matlab, improvement in Peak Signal to Noise Ratio (PSNR) of the received image and low complexity for equalization is demonstrated remarkably. Comparing with no adaptive and no actual channel equalization scheme, the proposed scheme saves over 6 dB when PSNR=40 dB.

  13. Utilization of Internet Protocol-Based Voice Systems in Remote Payload Operations

    Science.gov (United States)

    Chamberlain, jim; Bradford, Bob; Best, Susan; Nichols, Kelvin

    2002-01-01

    Due to limited crew availability to support science and the large number of experiments to be operated simultaneously, telescience is key to a successful International Space Station (ISS) science program. Crew, operations personnel at NASA centers, and researchers at universities and companies around the world must work closely together to per orm scientific experiments on-board ISS. The deployment of reliable high-speed Internet Protocol (IP)-based networks promises to greatly enhance telescience capabilities. These networks are now being used to cost-effectively extend the reach of remote mission support systems. They reduce the need for dedicated leased lines and travel while improving distributed workgroup collaboration capabilities. NASA has initiated use of Voice over Internet Protocol (VoIP) to supplement the existing mission voice communications system used by researchers at their remote sites. The Internet Voice Distribution System (IVoDS) connects remote researchers to mission support "loopsll or conferences via NASA networks and Internet 2. Researchers use NODS software on personal computers to talk with operations personnel at NASA centers. IVoDS also has the ;capability, if authorized, to allow researchers to communicate with the ISS crew during experiment operations. NODS was developed by Marshall Space Flight Center with contractors & Technology, First Virtual Communications, Lockheed-Martin, and VoIP Group. NODS is currently undergoing field-testing with full deployment for up to 50 simultaneous users expected in 2002. Research is being performed in parallel with IVoDS deployment for a next-generation system to qualitatively enhance communications among ISS operations personnel. In addition to the current voice capability, video and data/application-sharing capabilities are being investigated. IVoDS technology is also being considered for mission support systems for programs such as Space Launch Initiative and Homeland Defense.

  14. LEOcom: communication system for low earth orbit satellites for voice, data and facsimile; LEOcom - sistema de comunicacao por satelites de orbita terrestre baixa para voz, dados e facsimile

    Energy Technology Data Exchange (ETDEWEB)

    Giacaglia, G.E.O.; Lamas, W.Q. [Universidade de Taubate (UNITAU), SP (Brazil). Programa de Pos-graduacao em Engenharia Mecanica], E-mail: giorgio@unitau.br; Ceballos, D.C. [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil); Pereira, J.J. [Comando-Geral de Tecnologia Aeroespacial (CTA), Sao Jose dos Campos, SP (Brazil)

    2009-07-01

    This paper provides a basic description of a Communication System for Low Earth Orbit Satellites that can provide voice, data and facsimile to hundreds of countries located in equatorial land between + and - 20 deg latitude, reaching higher latitudes, depending on the location of the onshore terminal. As a point high, it emphasizes its opportunity to support the control of networks transmission of electricity, in any area, and plants generation, located in remote areas, and support any type of operation in these regions. It is the aim of this work to reactivate a good project for Brazil and the tropical world.

  15. 47 CFR 73.1400 - Transmission system monitoring and control.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Transmission system monitoring and control. 73... be accomplished by either: (i) Direct supervision and control of transmission system parameters by a person at the transmitter site; or (ii) Remote control of the transmission system by a person at the main...

  16. 47 CFR 73.626 - DTV distributed transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false DTV distributed transmission systems. 73.626... RADIO BROADCAST SERVICES Television Broadcast Stations § 73.626 DTV distributed transmission systems. (a... distributed transmission system (DTS). Except as expressly provided in this section, DTV stations operating...

  17. The hearing voices network: initial lessons and future directions for mental health professionals and Systems of Care.

    Science.gov (United States)

    Styron, Thomas; Utter, Lauren; Davidson, Larry

    2017-02-01

    For more than two decades, the Hearing Voices Network (HVN) has provided alternative approaches to supporting voice hearers, and an emerging body of research is now confirming their value. HVN approaches present unique opportunities and challenges for mental health professionals and systems of care that work with individuals who hear voices. An overview of the HVN is presented, including its history, principles and approaches. HVN approaches are compared and contrasted with traditional mental health treatments. HVN's potential contribution to the transformation of mental health care is discussed. Directions for future research are presented.

  18. 75 FR 30845 - Request Voucher for Grant Payment and Line of Credit Control System (LOCCS) Voice Response System...

    Science.gov (United States)

    2010-06-02

    ... URBAN DEVELOPMENT Request Voucher for Grant Payment and Line of Credit Control System (LOCCS) Voice... is soliciting public comments on the subject proposal. Payment request vouchers for distribution of.... This Notice Also Lists the Following Information Title of Proposal: Request Voucher for Grant...

  19. Simulation of full duplex data transmission in ROF system using Optisystem

    Directory of Open Access Journals (Sweden)

    Sandeep Singh

    2012-06-01

    Full Text Available Wireless coverage of the end-user domain; be it outdoors or indoors, is poised to become an essential part of broadband communication networks. In order to offer integrated broadband services (combining voice, data, video, multimedia services, and new value added services, systems will need to offer higher data transmission capacities. The need for increased capacity per unit area leads to higher operating frequencies, smaller radio cells and large number of base stations (BSs, therefore cost-effective BS development is a key success to the market. For this radio over fiber (RoF technology has been proposed since it provides functionally simple BSs that are connected to a central station (CS via an optical fiber. A full-duplex data and video signal transmission over single-mode fiber (SMF based on wavelengthdivision-multiplexing (WDM and an optical add-drop multiplexing (OADM technique is proposed and simulated. Four data signals of 1.25 Gb/s /9.1-9.4GHz are transmitted over long-haul single-mode fiber for downlink transmission. For uplink transmission, four data signals, each from a BS, of 1.25 Gb/s/9.6-9.9GHz is used. Good bit error rate (BER performances were achieved for both down-link and up-link transmissions in our full-duplex RoF transport system.

  20. AN EFFICIENT VOICE SCRAMBLING TECHNIQUE FOR NEXT GENERATION COMMUNICATION SYSTEMS

    Directory of Open Access Journals (Sweden)

    Dhanya G

    2016-02-01

    Full Text Available The OFDM scrambler is most widely used for secure communication. In order to eliminate the intelligibility of speech, speech scrambling is used. Many of the scrambling techniques shows poor performance, to improve the efficiency of the scrambler an efficient speech scrambling technique, random permutation with pseudorandom- generator under multipath fading is proposed. The Common Intelligibility Scale (CIS and Speech Transmission Index (STI are used to predict the intelligibility of speech. Also to evaluate the performance of speech the BER (Bit Error Rate and the SINR (Signal to Interference plus Noise Ratio was used. By the measurement of PESQ (Perceptual Evaluation of Speech Quality the recovered speech quality was observed. The simulations show that OFDM scrambler is a best technique for providing extremely high data security for 4G mobile communication when compared to a conventional technique.

  1. Multi-transmission-line-beam interactive system

    Energy Technology Data Exchange (ETDEWEB)

    Figotin, Alexander; Reyes, Guillermo [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)

    2013-11-15

    We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube due to J. R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

  2. AN IMPROVED ALGORITHM OF GMM VOICE CONVERSION SYSTEM BASED ON CHANGING THE TIME-SCALE

    Institute of Scientific and Technical Information of China (English)

    Zhou Ying; Zhang Linghua

    2011-01-01

    This paper improves and presents an advanced method of the voice conversion system based on Gaussian Mixture Models (GMM) models by changing the time-scale of speech.The Speech Transformation and Representation using Adaptive Interpolation of weiGHTed spectrum (STRAIGHT) model is adopted to extract the spectrum features,and the GMM models are trained to generate the conversion function.The spectrum features of a source speech will be converted by the conversion function.The time-scale of speech is changed by extracting the converted features and adding to the spectrum.The conversion voice was evaluated by subjective and objective measurements.The results confirm that the transformed speech not only approximates the characteristics of the target speaker,but also more natural and more intelligible.

  3. Parameterless-Growing-SOM and Its Application to a Voice Instruction Learning System

    Directory of Open Access Journals (Sweden)

    Takashi Kuremoto

    2010-01-01

    Full Text Available An improved self-organizing map (SOM, parameterless-growing-SOM (PL-G-SOM, is proposed in this paper. To overcome problems existed in traditional SOM (Kohonen, 1982, kinds of structure-growing-SOMs or parameter-adjusting-SOMs have been invented and usually separately. Here, we combine the idea of growing SOMs (Bauer and Villmann, 1997; Dittenbach et al. 2000 and a parameterless SOM (Berglund and Sitte, 2006 together to be a novel SOM named PL-G-SOM to realize additional learning, optimal neighborhood preservation, and automatic tuning of parameters. The improved SOM is applied to construct a voice instruction learning system for partner robots adopting a simple reinforcement learning algorithm. User's instructions of voices are classified by the PL-G-SOM at first, then robots choose an expected action according to a stochastic policy. The policy is adjusted by the reward/punishment given by the user of the robot. A feeling map is also designed to express learning degrees of voice instructions. Learning and additional learning experiments used instructions in multiple languages including Japanese, English, Chinese, and Malaysian confirmed the effectiveness of our proposed system.

  4. WiFi Voice Communication System Based on QT%基于QT的WiFi语音通信系统

    Institute of Scientific and Technical Information of China (English)

    赵付轩; 杨斌

    2012-01-01

    Aiming at speech signal acquisition in embedded system, the design uses UDP protocol for data transmission, uses Socket programming to ensure the reliability of data transmission and realizes LAN speech communication from end to end. This paper describes how to design and develop LAN real-time voice communication software based on QT and Linux development platform by using existing audio programming and network programming knowledge.%针对嵌入式系统语音信号的采集,采用UDP协议进行数据传输,运用Socket编程保证数据传输的可靠性,实现局域网里端到端的语音通信.主要阐述了如何在Linux开发平台上,利用现有的音频编程和网络编程知识,设计和开发局域网里基于QT的实时语音通信软件.

  5. Flexible AC transmission systems: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Edris, Abdel-Aty [Electric Power Research Inst., Palo Alto, CA (United States). Electric Systems Division

    1994-12-31

    Flexible AC transmission systems (FACTS) is a concept promoting the use of power electronic controllers to enhance the controllability and usable capacity of AC transmission. This paper presents the state of the art of FACTS and the status of the current projects for the application of the FACTS controllers in transmission systems. (author) 8 refs., 8 figs.

  6. Combined heuristic with fuzzy system to transmission system expansion planning

    Energy Technology Data Exchange (ETDEWEB)

    Silva Sousa, Aldir; Asada, Eduardo N. [University of Sao Paulo, Sao Carlos School of Engineering, Department of Electrical Engineering Av. Trabalhador Sao-carlense, 400, 13566-590 Sao Carlos, SP (Brazil)

    2011-01-15

    A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)

  7. Electric transmission line flashover prediction system

    Science.gov (United States)

    Amarh, Felix

    Near industrial, agricultural, or coastal areas, contamination is a frequent cause of insulator flashover, most cases of which result in lengthy service interruptions. Utilities spend significant amounts of money on insulator washing and cleaning before the restoration of the service. Laboratory studies and industrial experience have shown that both contamination and wetting of insulator surfaces, which initiate the flow of leakage current, are required for insulator flashover. The leakage current leading to flashover has distinctive stages of development. Flashover is preceded by dry-band arcing and extension of the arc to bridge the insulator. This combination significantly modifies both the magnitude and shape of the leakage current. A condition-based monitoring (CBM) system that monitors the easily measurable insulator leakage current as a means of assessing pollution severity and would possibly predict an approaching flashover could prove beneficial to utilities. The overall aim of this project is the development of a system that monitors pollution build-up through the signature changes in the leakage current and alerts an operator when there is a danger of flashover. The operator can, in turn, order maintenance personnel to wash the insulators. This will safeguard against unforeseen flashovers, since the system is constantly being monitored and diagnosed. Additionally, the washing cycles of insulators will be optimized, saving money and eventually rendering the power transmission system more reliable.

  8. Microfluidic system for transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ring, Elisabeth A [ORNL; De Jonge, Niels [ORNL

    2010-01-01

    We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

  9. Smart Homes with Voice Activated Systems for Disabled People

    National Research Council Canada - National Science Library

    Bekir Busatlic; Nejdet Dogru; Isaac Lera; Enes Sukic

    2017-01-01

    Smart home refers to the application of various technologies to semi-unsupervised home control It refers to systems that control temperature, lighting, door locks, windows and many other appliances...

  10. The Bellevue Classification System: nursing's voice upon the library shelves.

    Science.gov (United States)

    Mages, Keith C

    2011-01-01

    This article examines the inspiration, construction, and meaning of the Bellevue Classification System (BCS), created during the 1930s for use in the Bellevue School of Nursing Library. Nursing instructor Ann Doyle, with assistance from librarian Mary Casamajor, designed the BCS after consulting with library leaders and examining leading contemporary classification systems, including the Dewey Decimal Classification and Library of Congress, Ballard, and National Health Library classification systems. A close textual reading of the classes, subclasses, and subdivisions of these classification systems against those of the resulting BCS, reveals Doyle's belief that the BCS was created not only to organize the literature, but also to promote the burgeoning intellectualism and professionalism of early twentieth-century American nursing.

  11. New Comparison of HVDC and HVAC Transmission system

    Directory of Open Access Journals (Sweden)

    Vahid Behravesh

    2012-06-01

    Full Text Available Alternating current (AC is the main driving force in the industries and residential areas, but for the long transmission line (more than 400 miles AC transmission is more expensive than that of direct current (DC. Technically, AC transmission line control is more complicated because of the frequency. DC transmission does not have these limitations, which has led to build long HVDC transmission lines over the last 40 years. HVDC technology made possible to transfer bulk power over long distances. This paper presents a comparative evaluation of HVDC and HVAC transmission systems .

  12. Development of the Field of Flexible AC Transmission Systems (FACTS)

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@ Theoretical and technological development of large capacity power electronics and flexible AC transmission systems are one of the most important projects developed by Tsinghua University. The Flexible AC Transmission System (FACTS) technology which uses power electronics to improve the efficiency and quality of the electrical generation, transmission and distribution system is considered to be one of the most significant technological innovations for power systems in the 20th century. The advanced static var generator (ASVG) is a key FACTS device.

  13. The Female Voice: Applications to Bowen's Family Systems Theory.

    Science.gov (United States)

    Knudson-Martin, Carmen

    1994-01-01

    Responds to calls from feminist scholars to address potential biases against women in theories of family therapy. Summarizes findings from studies of female development and integrates findings into expanded model of Bowen's family systems theory. Includes case example comparing expanded model with traditional application of Bowen's theory.…

  14. Actuator prototype system by voice commands using free software

    Directory of Open Access Journals (Sweden)

    Jaime Andrango

    2016-06-01

    Full Text Available This prototype system is a software application that through the use of techniques of digital signal processing, extracts information from the user's speech, which is then used to manage the on/off actuator on a peripheral computer when vowels are pronounced. The method applies spectral differences. The application uses the parallel port as actuator, with the information recorded in the memory address 378H. This prototype was developed using free software tools for its versatility and dynamism, and to allow other researchers to base on it for further studies.

  15. The effect of different navigation voices on trust and attention while using in-vehicle navigation systems.

    Science.gov (United States)

    Large, David R; Burnett, Gary E

    2014-06-01

    Automobiles are suffused with computers and technology designed to support drivers at all levels of the driving hierarchy. Classic secondary devices, such as in-vehicle navigation systems (IVNS), present strategic and tactical information to drivers. In order to mitigate the potential distraction and workload when interacting with these devices while driving, IVNS often employ voices to deliver navigational instructions. In contrast, voices are used during interpersonal encounters to engage the listener, provide clues about the speaker's personality and make judgments about them, for example, whether to like them and to trust them. A study conducted within a fixed-based medium-fidelity driving simulator investigated if drivers made similar 'personality' attributions to voices emanating from an IVNS and if this subsequently affected how they engaged with the device while driving. Twenty-nine experienced drivers and IVNS users drove to a specified destination with a simulated IVNS and authentically reproduced UK road signage to support their route-finding. Either of two navigation voices were used; one considered 'high-trust' and the other 'low-trust.' Presented with a conflict scenario, where the verbal route guidance differed to the road signs, 22 drivers followed the IVNS instruction rather than the road signs. Of these, the majority were using the 'high-trust' voice. A post-drive questionnaire revealed that, despite the fact that message content and delivery remained equivalent, participants recognized different attributes ('personalities') associated with each of the navigation voices. This influenced their attitudes towards them, including how much they liked them, their preferences for use, and the level of trust that they associated with each voice. While these, so-called, social responses may be invited and indeed encouraged in other contexts, in the automotive domain they are likely to conflict with the intended benefits of using a voice to deliver route

  16. Wireless Controlled Methods via Voice and Internet (e-mail for Home Automation System

    Directory of Open Access Journals (Sweden)

    R.A.Ramlee

    2013-08-01

    Full Text Available This paper presents a wireless Home Automation System (HAS that mainly performed by computer. The system is designed with several control methods in order to control the target electrical appliances. This various control methods implemented to fulfill the needs of users at home even at outside. The computer application is designed in Microsoft Windows OS that integrated with speech recognition voice control by using Microsoft Speech Application Programming Interface (SAPI. The voice control method provides more convenience especially to the blind and paralyzed users at home. This system is designed to perform short distance control by using wireless Bluetooth technology and long distance control by using Simple Mail Transfer Protocol (SMTP email control method. The short distance control is considered as the control that performed inside the house. Moreover, the long distance control can be performed at everywhere by devices that installed with browser or email application, and also with the internet access. The system intended to control electrical appliances at home with relatively low cost design, user-friendly interface and ease of installation.

  17. Student Modelling in an Intelligent Tutoring System for the Passive Voice of English Language

    Directory of Open Access Journals (Sweden)

    Dimitris Maras

    2000-01-01

    Full Text Available This paper describes an intelligent multimedia tutoring system for the passive voice of the English grammar. The system may be used to present theoretical issues about the passive voice and to provide exercises that the student may solve. The main focus of the tutor is on the student's error diagnosis process, which is performed by the student modelling component. When the student types the solution to an exercise, the system examines the correctness of the answer. If the student's answer has been erroneous it attempts to diagnose the underlying misconception of the mistake. In order to provide individualised help, the system holds a profile for every student, the long term student model. The student’s progress and his/her usual mistakes are recorded to this long term student model. This kind of information is used for the individualised error diagnosis of the student in subsequent sessions. In addition, the information stored about the student can also be used for the resolution of an arising ambiguity, as to what the underlying cause of a student error has been.

  18. An embedded Video Transmission System Based on H.264

    Institute of Scientific and Technical Information of China (English)

    GAO Jing-min; LAN Ya-zhu

    2009-01-01

    In this paper,an embedded Video Transmission System based on H.264 is proposed.In this system,the latest video compression standards-H.264 is used as video codec algorithm,the i.mx27 is used as the center processors of the system,embedded Linux is used as the operating system and RTP/UDP is used as the network transmission protocol.The paper introduces the design way and the frame of the system.The test results of the system show that the proposed system can support good quality transmission of the video information.The parameters with the transmission are D1,720*480,30fps and 4Mbps.In addition,in order to ensure the security of the video information in the transmission,the system provides the encryption to the information in the process of compressing.

  19. Distributed information-processing system with voice control based on OS Android

    Directory of Open Access Journals (Sweden)

    E. V. Apolonov

    2012-12-01

    Full Text Available Introduction: Trends of increase of ACS and AIS and their use in everyday life are discussed. The need a voice mode of human interaction with AIS is mentioned. Noticed that network integration of AIS allows to combine their resources and contributes to progress in speech recognition. The emergence of smart phones and their widespread use is the desire to use them as personal voice terminals for access to distributed information networks. Main part: Possibility of use of Android-based personal portable mobile devices (PPMD like terminals and like autonomous units, as well as possibility of use of Windows-based stationary PC like servers of distributed data-processing system (DDPS with voice control are considered. Criteria for selection of PPMD and OS of client terminals, as well as requirements DDPS and its structure are formulated. Concept of building of DDPS by "client - server" and "a lot of clients — many servers" technologies are submitted. Concept of a PPMD virtual interface and server virtual interface are offered. Communication between threads within the process of the PPMD virtual interface of client terminal and the interaction between the processes of the client and server in the autonomous mode, as well as in the DDPS mode are considered. The results of experimental tests of the prototype of DDPS when exchanging data between Windows and Android clients, and Windows Server are running; the accuracy and reliability of embedded solutions and scalability of DDPS are confirmed. Conclusions: Modern PPMD on Android OS with can be used as terminal devices for construction on the basis of their different specialized voice control DDPS with technology "client - server" and "a lot of customers - many servers". Unification APIs of PPMD with different OS can be done by implementing a virtual PPMD interface. Exchanging data between processes of DDPS better sell through technology Berkeley sockets, which are supported by most modern operating

  20. Transmission techniques for emergent multicast and broadcast systems

    CERN Document Server

    da Silva, Mario Marques; Dinis, Rui; Souto, Nuno; Silva, Joao Carlos

    2010-01-01

    Describing efficient transmission schemes for broadband wireless systems, Transmission Techniques for Emergent Multicast and Broadcast Systems examines advances in transmission techniques and receiver designs capable of supporting the emergent wireless needs for multimedia broadcast and multicast service (MBMS) requirements. It summarizes the research and development taking place in wireless communications for multimedia MBMS and addresses the means to improved spectral efficiency to allow for increased user bit rate, as well as increased capacity of the digital cellular radio network.The text

  1. Voice Matching Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Abhishek Bal

    2014-03-01

    Full Text Available In this paper, the use of Genetic Algorithm (GA for voice recognition is described. The practical application of Genetic Algorithm (GA to the solution of engineering problem is a rapidly emerging approach in the field of control engineering and signal processing. Genetic algorithms are useful for searching a space in multi-directional way from large spaces and poorly defined space. Voice is a signal of infinite information. Digital processing of voice signal is very important for automatic voice recognition technology. Nowadays, voice processing is very much important in security mechanism due to mimicry characteristic. So studying the voice feature extraction in voice processing is very necessary in military, hospital, telephone system, investigation bureau and etc. In order to extract valuable information from the voice signal, make decisions on the process, and obtain results, the data needs to be manipulated and analyzed. In this paper, if the instant voice is not matched with same person’s reference voices in the database, then Genetic Algorithm (GA is applied between two randomly chosen reference voices. Again the instant voice is compared with the result of Genetic Algorithm (GA which is used, including its three main steps: selection, crossover and mutation. We illustrate our approach with different sample of voices from human in our institution.

  2. System and method for characterizing voiced excitations of speech and acoustic signals, removing acoustic noise from speech, and synthesizing speech

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, Greg C.; Holzrichter, John F.; Ng, Lawrence C.

    2006-02-14

    The present invention is a system and method for characterizing human (or animate) speech voiced excitation functions and acoustic signals, for removing unwanted acoustic noise which often occurs when a speaker uses a microphone in common environments, and for synthesizing personalized or modified human (or other animate) speech upon command from a controller. A low power EM sensor is used to detect the motions of windpipe tissues in the glottal region of the human speech system before, during, and after voiced speech is produced by a user. From these tissue motion measurements, a voiced excitation function can be derived. Further, the excitation function provides speech production information to enhance noise removal from human speech and it enables accurate transfer functions of speech to be obtained. Previously stored excitation and transfer functions can be used for synthesizing personalized or modified human speech. Configurations of EM sensor and acoustic microphone systems are described to enhance noise cancellation and to enable multiple articulator measurements.

  3. System and method for characterizing voiced excitations of speech and acoustic signals, removing acoustic noise from speech, and synthesizing speech

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, Greg C. (Livermore, CA); Holzrichter, John F. (Berkeley, CA); Ng, Lawrence C. (Danville, CA)

    2006-08-08

    The present invention is a system and method for characterizing human (or animate) speech voiced excitation functions and acoustic signals, for removing unwanted acoustic noise which often occurs when a speaker uses a microphone in common environments, and for synthesizing personalized or modified human (or other animate) speech upon command from a controller. A low power EM sensor is used to detect the motions of windpipe tissues in the glottal region of the human speech system before, during, and after voiced speech is produced by a user. From these tissue motion measurements, a voiced excitation function can be derived. Further, the excitation function provides speech production information to enhance noise removal from human speech and it enables accurate transfer functions of speech to be obtained. Previously stored excitation and transfer functions can be used for synthesizing personalized or modified human speech. Configurations of EM sensor and acoustic microphone systems are described to enhance noise cancellation and to enable multiple articulator measurements.

  4. System and method for characterizing voiced excitations of speech and acoustic signals, removing acoustic noise from speech, and synthesizing speech

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, Greg C.; Holzrichter, John F.; Ng, Lawrence C.

    2004-03-23

    The present invention is a system and method for characterizing human (or animate) speech voiced excitation functions and acoustic signals, for removing unwanted acoustic noise which often occurs when a speaker uses a microphone in common environments, and for synthesizing personalized or modified human (or other animate) speech upon command from a controller. A low power EM sensor is used to detect the motions of windpipe tissues in the glottal region of the human speech system before, during, and after voiced speech is produced by a user. From these tissue motion measurements, a voiced excitation function can be derived. Further, the excitation function provides speech production information to enhance noise removal from human speech and it enables accurate transfer functions of speech to be obtained. Previously stored excitation and transfer functions can be used for synthesizing personalized or modified human speech. Configurations of EM sensor and acoustic microphone systems are described to enhance noise cancellation and to enable multiple articulator measurements.

  5. System And Method For Characterizing Voiced Excitations Of Speech And Acoustic Signals, Removing Acoustic Noise From Speech, And Synthesizi

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, Greg C. (Livermore, CA); Holzrichter, John F. (Berkeley, CA); Ng, Lawrence C. (Danville, CA)

    2006-04-25

    The present invention is a system and method for characterizing human (or animate) speech voiced excitation functions and acoustic signals, for removing unwanted acoustic noise which often occurs when a speaker uses a microphone in common environments, and for synthesizing personalized or modified human (or other animate) speech upon command from a controller. A low power EM sensor is used to detect the motions of windpipe tissues in the glottal region of the human speech system before, during, and after voiced speech is produced by a user. From these tissue motion measurements, a voiced excitation function can be derived. Further, the excitation function provides speech production information to enhance noise removal from human speech and it enables accurate transfer functions of speech to be obtained. Previously stored excitation and transfer functions can be used for synthesizing personalized or modified human speech. Configurations of EM sensor and acoustic microphone systems are described to enhance noise cancellation and to enable multiple articulator measurements.

  6. MIMO Identical Eigenmode Transmission System (IETS) - A Channel Decomposition Perspective

    CERN Document Server

    Shakir, M Zeeshan

    2010-01-01

    In the past few years considerable attention has been given to the design of Multiple-Input Multiple-Output (MIMO) Eigenmode Transmission Systems (EMTS). This paper presents an in-depth analysis of a new MIMO eigenmode transmission strategy. The non-linear decomposition technique called Geometric Mean Decomposition (GMD) is employed for the formation of eigenmodes over MIMO flatfading channel. Exploiting GMD technique, identical, parallel and independent transmission pipes are created for data transmission at higher rate. The system based on such decomposition technique is referred to as MIMO Identical Eigenmode Transmission System (IETS). The comparative analysis of the MIMO transceiver design exploiting nonlinear and linear decomposition techniques for variable constellation is presented in this paper. The new transmission strategy is tested in combination with the Vertical Bell Labs Layered Space Time (V-BLAST) decoding scheme using different number of antennas on both sides of the communication link. The ...

  7. Design of real-time voice over internet protocol system under bandwidth network

    Science.gov (United States)

    Zhang, Li; Gong, Lina

    2017-04-01

    With the increasing bandwidth of the network and network convergence accelerating, VoIP means of communication across the network is becoming increasingly popular phenomenon. The real-time identification and analysis for VOIP flow over backbone network become the urgent needs and research hotspot of network operations management. Based on this, the paper proposes a VoIP business management system over backbone network. The system first filters VoIP data stream over backbone network and further resolves the call signaling information and media voice. The system can also be able to design appropriate rules to complete real-time reduction and presentation of specific categories of calls. Experimental results show that the system can parse and process real-time backbone of the VoIP call, and the results are presented accurately in the management interface, VoIP-based network traffic management and maintenance provide the necessary technical support.

  8. V2S: Voice to Sign Language Translation System for Malaysian Deaf People

    Science.gov (United States)

    Mean Foong, Oi; Low, Tang Jung; La, Wai Wan

    The process of learning and understand the sign language may be cumbersome to some, and therefore, this paper proposes a solution to this problem by providing a voice (English Language) to sign language translation system using Speech and Image processing technique. Speech processing which includes Speech Recognition is the study of recognizing the words being spoken, regardless of whom the speaker is. This project uses template-based recognition as the main approach in which the V2S system first needs to be trained with speech pattern based on some generic spectral parameter set. These spectral parameter set will then be stored as template in a database. The system will perform the recognition process through matching the parameter set of the input speech with the stored templates to finally display the sign language in video format. Empirical results show that the system has 80.3% recognition rate.

  9. 47 CFR 73.49 - AM transmission system fencing requirements.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false AM transmission system fencing requirements. 73.49 Section 73.49 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.49 AM transmission system fencing...

  10. 47 CFR 73.44 - AM transmission system emission limitations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false AM transmission system emission limitations. 73... SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.44 AM transmission system emission limitations. (a) The emissions of stations in the AM service shall be attenuated in accordance with the...

  11. Admission Control of Integrated Voice and Data CDMA/TDD System Considering Asymmetric Traffic and Power Limit

    Institute of Scientific and Technical Information of China (English)

    CAOYanbo; ZHOUBin; LIChengshu

    2004-01-01

    In this paper, we research an admission control scheme of integrated voice and data CDMA/TDD (Code division multiple access/Time division duplex) system considering asymmetric traffic and power limit. A new user can access the system only if the outage probabilities it experiences on the uplink and downlink time slots are below a threshold value. Based on the power limit the results show the voice and data blocking probabilities under different cell coverage~ arrival rates and various uplink/downlink time slot allocation patterns. Furthermore, multicode and multislot schemes are also evaluated under the presented admission control scheme.

  12. Optimization of transmission system design based on genetic algorithm

    Directory of Open Access Journals (Sweden)

    Xianbing Chen

    2016-05-01

    Full Text Available Transmission system is a crucial precision mechanism for twin-screw chemi-mechanical pulping equipment. The structure of the system designed by traditional method is not optimal because the structure designed by the traditional methods is easy to fall into the local optimum. To achieve the global optimum, this article applies the genetic algorithm which has grown in recent years in the field of structure optimization. The article uses the volume of transmission system as the objective function to optimize the structure designed by traditional method. Compared to the simulation results, the original structure is not optimal, and the optimized structure is tighter and more reasonable. Based on the optimized results, the transmission shafts in the transmission system are designed and checked, and the parameters of the twin screw are selected and calculated. The article provided an effective method to design the structure of transmission system.

  13. Voice Disorders

    Science.gov (United States)

    Voice is the sound made by air passing from your lungs through your larynx, or voice box. In your larynx are your vocal cords, ... to make sound. For most of us, our voices play a big part in who we are, ...

  14. Every Voice

    Science.gov (United States)

    Patrick, Penny

    2008-01-01

    This article discusses how the author develops an approach that allows her students, who are part of the marginalized population, to learn the power of their own voices--not just their writing voices, but their oral voices as well. The author calls it "TWIST": Thoughts, Writing folder, Inquiring mind, Supplies, and Teamwork. It is where…

  15. Every Voice

    Science.gov (United States)

    Patrick, Penny

    2008-01-01

    This article discusses how the author develops an approach that allows her students, who are part of the marginalized population, to learn the power of their own voices--not just their writing voices, but their oral voices as well. The author calls it "TWIST": Thoughts, Writing folder, Inquiring mind, Supplies, and Teamwork. It is where…

  16. Voice restoration

    NARCIS (Netherlands)

    Hilgers, F.J.M.; Balm, A.J.M.; van den Brekel, M.W.M.; Tan, I.B.; Remacle, M.; Eckel, H.E.

    2010-01-01

    Surgical prosthetic voice restoration is the best possible option for patients to regain oral communication after total laryngectomy. It is considered to be the present "gold standard" for voice rehabilitation of laryngectomized individuals. Surgical prosthetic voice restoration, in essence, is alwa

  17. Nonlinear system guidance in the presence of transmission zero dynamics

    Science.gov (United States)

    Meyer, G.; Hunt, L. R.; Su, R.

    1995-01-01

    An iterative procedure is proposed for computing the commanded state trajectories and controls that guide a possibly multiaxis, time-varying, nonlinear system with transmission zero dynamics through a given arbitrary sequence of control points. The procedure is initialized by the system inverse with the transmission zero effects nulled out. Then the 'steady state' solution of the perturbation model with the transmission zero dynamics intact is computed and used to correct the initial zero-free solution. Both time domain and frequency domain methods are presented for computing the steady state solutions of the possibly nonminimum phase transmission zero dynamics. The procedure is illustrated by means of linear and nonlinear examples.

  18. Voice over Internet Protocol (VoIP) Technology as a Global Learning Tool: Information Systems Success and Control Belief Perspectives

    Science.gov (United States)

    Chen, Charlie C.; Vannoy, Sandra

    2013-01-01

    Voice over Internet Protocol- (VoIP) enabled online learning service providers struggling with high attrition rates and low customer loyalty issues despite VoIP's high degree of system fit for online global learning applications. Effective solutions to this prevalent problem rely on the understanding of system quality, information quality, and…

  19. 40 Gb/s optical transmission systems

    DEFF Research Database (Denmark)

    Buxens Azcoaga, Alvaro Juan; Nielsen, Steen Krogh

    2003-01-01

    application (maximum distance of 40 km) the maximum PMD coeficient allowed in the transmission fiber, 0.4 ps=pkm, is below the values defined by actual standards, 0.5 ps=pkm. The most promising PMD compensation methods are presented and their advantages and disadvantages are discussed. A PMD compensator based...

  20. Measurement of Transmission Error Including Backlash in Angle Transmission Mechanisms for Mechatronic Systems

    Science.gov (United States)

    Ming, Aiguo; Kajitani, Makoto; Kanamori, Chisato; Ishikawa, Jiro

    The characteristics of angle transmission mechanisms exert a great influence on the servo performance in the robotic or mechatronic mechanism. Especially, the backlash of angle transmission mechanism is preferable the small amount. Recently, some new types of gear reducers with non-backlash have been developed for robots. However, the measurement and evaluation method of the backlash of gear trains has not been considered except old methods which can statically measure at only several meshing points of gears. This paper proposes an overall performance testing method of angle transmission mechanisms for the mechatronic systems. This method can measure the angle transmission error both clockwise and counterclockwise. In addition the backlash can be continuously measured in all meshing positions automatically. This system has been applied to the testing process in the production line of gear reducers for robots, and it has been effective for reducing the backlash of the gear trains.

  1. Security of the data transmission in the industrial control system

    Directory of Open Access Journals (Sweden)

    Marcin Bednarek

    2015-12-01

    Full Text Available The theme of this paper is to present the data transmission security system between the stations of the industrial control system. The possible options for secure communications between process stations, as well as between process and operator station are described. Transmission security mechanism is based on algorithms for symmetric and asymmetric encryption. The authentication process uses a software token algorithm and a one-way hash function. The algorithm for establishing a secured connection between the stations, including the authentication process and encryption of data transmission is given. The process of securing the transmission consists of 4 sub-processes: (I authentication; (II asymmetric, public keys transmission; (III symmetric key transmission; (IV data transmission. The presented process of securing the transmission was realized in the industrial controller and emulator. For this purpose, programming languages in accordance with EN 61131 were used. The functions were implemented as user function blocks. This allows us to include a mixed code in the structure of the block (both: ST and FBD. Available function categories: support of the asymmetric encryption; asymmetric encryption utility functions; support of the symmetric encryption; symmetric encryption utility functions; support of the hash value calculations; utility functions of conversion.[b]Keywords[/b]: transmission security, encryption, authentication, industrial control system

  2. Strategic Generation with Conjectured Transmission Price Responses in a Mixed Transmission Pricing System. Part 1. Formulation

    Energy Technology Data Exchange (ETDEWEB)

    Hobbs, B.F. [Department of Geography and Environmental Engineering, The Johns Hopkins University, Baltimore, MD (United States); Rijkers, F.A.M. [Office of Energy Regulation DTe, Den Haag (Netherlands)

    2004-05-01

    The conjectured supply function (CSF) model calculates an oligopolistic equilibrium among competing generating companies (GenCos), presuming that GenCos anticipate that rival firms will react to price increases by expanding their sales at an assumed rate. The CSF model is generalized here to include each generator's conjectures concerning how the price of transmission services (point-to-point service and constrained interfaces) will be affected by the amount of those services that the generator demands. This generalization reflects the market reality that large producers will anticipate that they can favorably affect transmission prices by their actions. The model simulates oligopolistic competition among generators while simultaneously representing a mixed transmission pricing system. This mixed system includes fixed transmission tariffs, congestion-based pricing of physical transmission constraints (represented as a linearized dc load flow), and auctions of interface capacity in a path-based pricing system. Pricing inefficiencies, such as export fees and no credit for counterflows, can be simulated. The model is formulated as a linear mixed complementarity problem, which enables very large market models to be solved. In the second paper of this two-paper series, the capabilities of the model are illustrated with an application to northwest Europe, where transmission pricing is based on such a mixture of approaches.

  3. Underwater Acoustic Image Transmission System Based on DSP

    Institute of Scientific and Technical Information of China (English)

    Cheng En; Xu Ru

    2002-01-01

    The underwater acoustic image transmission system based on the high-speed DSP device TMS320C549 has been studied. We use Goertzel algorithm for source decoding and MFSK for modulation. Turbo code is used for channel coding and decoding. The purpose is to implement underwater video image data transmission.

  4. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  5. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  6. VoiceRelay: voice key operation using visual basic.

    Science.gov (United States)

    Abrams, Lise; Jennings, David T

    2004-11-01

    Using a voice key is a popular method for recording vocal response times in a variety of language production tasks. This article describes a class module called VoiceRelay that can be easily utilized in Visual Basic programs for voice key operation. This software-based voice key offers the precision of traditional voice keys (although accuracy is system dependent), as well as the flexibility of volume and sensitivity control. However, VoiceRelay is a considerably less expensive alternative for recording vocal response times because it operates with existing PC hardware and does not require the purchase of external response boxes or additional experiment-generation software. A sample project demonstrating implementation of the VoiceRelay class module may be downloaded from the Psychonomic Society Web archive, www.psychonomic.org/archive.

  7. Youth Advisors Driving Action: hearing the youth voice in mental health systems of care.

    Science.gov (United States)

    Davis-Brown, Karen; Carter, Naeemah; Miller, Bethany D

    2012-03-01

    The Children's Mental Health Initiative (CMHI) is funded by the Center for Mental Health Services within the Substance Abuse and Mental Health Services Administration. CMHI assists communities in developing comprehensive, coordinated services for children with serious emotional disturbances and their families. Broadly speaking, these systems are designed to be child centered, youth guided, family driven, community based, and culturally competent. To assure implementation of the "youth-guided" core value in the national evaluation, an advisory group of youth coordinator/youth teams representing communities across the country was developed. This group chose the name YADA-Youth Advisors Driving Action. YADA has made a substantive contribution to national evaluation efforts by bringing the youth perspective and voice to its audience at the community and national levels. This article describes YADA's founding and development, as well as related implications for psychosocial nurses.

  8. Decision support system in an international-voice-services business company

    Science.gov (United States)

    Hadianti, R.; Uttunggadewa, S.; Syamsuddin, M.; Soewono, E.

    2017-01-01

    We consider a problem facing by an international telecommunication services company in maximizing its profit. From voice services by controlling cost and business partnership. The competitiveness in this industry is very high, so that any efficiency from controlling cost and business partnership can help the company to survive in the very high competitiveness situation. The company trades voice traffic with a large number of business partners. There are four trading schemes that can be chosen by this company, namely, flat rate, class tiering, volume commitment, and revenue capped. Each scheme has a specific characteristic on the rate and volume deal, where the last three schemes are regarded as strategic schemes to be offered to business partner to ensure incoming traffic volume for both parties. This company and each business partner need to choose an optimal agreement in a certain period of time that can maximize the company’s profit. In this agreement, both parties agree to use a certain trading scheme, rate and rate/volume/revenue deal. A decision support system is then needed in order to give a comprehensive information to the sales officers to deal with the business partners. This paper discusses the mathematical model of the optimal decision for incoming traffic volume control, which is a part of the analysis needed to build the decision support system. The mathematical model is built by first performing data analysis to see how elastic the incoming traffic volume is. As the level of elasticity is obtained, we then derive a mathematical modelling that can simulate the impact of any decision on trading to the revenue of the company. The optimal decision can be obtained from these simulations results. To evaluate the performance of the proposed method we implement our decision model to the historical data. A software tool incorporating our methodology is currently in construction.

  9. Vibration transmissibility characteristics of smart spring vibration isolation system

    Institute of Scientific and Technical Information of China (English)

    倪德; 朱如鹏; 陆凤霞; 鲍和云; 付秋菊

    2014-01-01

    The objective of this work was to study the vibration transmissibility characteristics of the undamped and damped smart spring systems. The frequency response characteristics of them were analyzed by using the equivalent linearization technique, and the possible types of the system motion were distinguished by using the starting and ending frequencies. The influences of system parameters on the vibration transmissibility characteristics were discussed. The following conclusions may be drawn from the analysis results. The undamped smart spring system may simultaneously have one starting frequency and one ending frequency or only have one starting frequency, and the damped system may simultaneously have two starting frequencies and one ending frequency. There is an optimal control parameter to make the peak value of the vibration transmissibility curve of the system be minimum. When the mass ratio is far away from the stiffness ratio, the vibration transmissibility is small. The effect of the damping ratio on the system vibration transmissibility is significant while the control parameter is less than its optimal value. But the influence of the relative damping ratio on the vibration transmissibility is small.

  10. Design of MAGLEV Information Transmission System by Radio Inductive Loop

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Kweun [Taejon National University of Technology (Korea, Republic of); Park, Seok Ha; Kim, Jong Bum; Kim, Yang Mo [Chungnam National University (Korea, Republic of); Park, Jeong Soo [ACE Technology (Korea, Republic of)

    1999-01-01

    This paper presents the information transmission between on-board and ground-site in MAGLEV Considering safety and high speed operation and density operation and density operation information, transmission between them is necessary. Therefore it is necessary for transmission system to ensure high speed transmission, low error rate, massive information, and reliability of information. To provide above conditions, 1.1km signal line assembly was constructed and Frequency Shift Keying(FSK) modulation and Open System Interconnection(OSI) based high-level data link control(HDLC) protocol are applied, To modulate digital signal for transmission from ground-site to on-board, carrier frequency of 70khz is used and 90khz is used for transmission from on-board to ground-site. Transmission speed is 2400bps for consideration of train speed, quantity of information, and data error rate. And this paper introduces information monitoring considering user interface and presents the method for an effective data transmission in MAGLEV which is now being tested and intends to provide for an intelligent train operation in future. (author). 9 refs., 9 figs., 1 tab.

  11. Alternative electrical transmission systems and their environmental impact

    Energy Technology Data Exchange (ETDEWEB)

    Schiefelbein, G.F.

    1977-08-01

    A general description is provided of electrical transmission systems as an aid in determining their environmental impacts. Alternating current, direct current, overhead systems, underground systems, and water crossings are treated. The cost, performance, reliability, safety, and environmental impact of these systems are compared.

  12. Design and implementation of Smart Voice system%Smart Voice系统的设计与实现

    Institute of Scientific and Technical Information of China (English)

    徐俊芳; 田素贞

    2012-01-01

    Aiming at the problem that the current speech synthesis systems has strong taste of speech machine and poor voice quality, Smart Voice, a kind of Chinese TTS system was designed, and the Smart Voice call implementation was given. The system used a hierarchical, modular program structure, completing the marker analysis, syntax analysis, sustain treatment, tone sandhi processing function. Especially in the sustain processor,waveform concatenation technology innovation was used,creating waveform internal circulation damper module to make a good degree of natural sustain. System operation results showed that Smart Voice sounded natural,and could provide high-speed flexible Chinese speech for the network,games and other computer applications.%针对目前我国语音合成系统合成的语音机器味较浓、语音质量较差的问题,设计和实现了一种中文TTS软件系统Smart Voice,并给出了Smart Voice的调用实现.该系统使用层次化、模块化的程序结构,完成了标记分析、语法分析、延音处理、变调处理等功能.尤其在延音处理器中,创新地采用波形拼接技术创制了波形内部循环的延音模块,使得声音在延音时具有很好的自然度.系统运行表明,Smart Voice发音自然,能为网络、游戏等各种计算机应用提供高速灵活的中文语音支持.

  13. Cost estimation of HVDC transmission system of Bangka's NPP candidates

    Science.gov (United States)

    Liun, Edwaren; Suparman

    2014-09-01

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  14. Transmission Reinforcements in the Central American Regional Power System

    Energy Technology Data Exchange (ETDEWEB)

    Elizondo, Marcelo A.; Vallem, Mallikarjuna R.; Samaan, Nader A.; Makarov, Yuri V.; Vyakaranam, Bharat; Nguyen, Tony B.; Munoz, Christian; Herrera, Ricardo; Midence, Diego; Shpitsberg, Anna

    2016-07-25

    The Central American regional interconnected power system (SER) connects the countries members of the Central American regional electricity market (MER): Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica, and Panama. The SER was a result of a long term regional effort, and was initially conceived to transfer 300 MW between countries. However, the current transfer limits between countries range from 70 MW to 300 MW. Regional entities, like CRIE (Regional Commission of Electrical Interconnection), EOR (Central American Regional System Operator), and CDMER (Board of Directors of the Central American Market) are working on coordinating the national transmission expansion plans with regional transmission planning efforts. This paper presents experience in Central America region to recommend transmission reinforcements to achieve 300 MW transfer capacity between any pair of member countries of the Central American regional electricity market (MER). This paper also provides a methodology for technical analysis and for coordination among the regional and national entities. This methodology is unique for transmission systems of these characteristics.

  15. Open access pricing methodology in economically adapted electric transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Rudnick, Hugh; Cura, Eliana; Palma, Rodrigo [Pontificia Univ. Catolica de Chile, Santiago (Chile). Dept. de Ingenieria Electrica

    1996-07-01

    Open access pricing methodologies are evaluated in a deregulated environment, as applied to an economically adapted electric transmission system over a ten year time horizon. A transmission planning methodology using a genetic algorithm is used to determine the adapted system and the required investment over the horizon. A production cost simulation algorithm is utilized to determine the operation of the hydroelectric system and the resultant short term marginal income. Different pricing methodologies to allocate the required supplement, as applied to the Chilean central interconnected electrical system, are evaluated: use of system, postage stamp and user benefit. The resultant payment allocations are assessed and their economic impact on participants is discussed. (author)

  16. Speaking in Character: Voice Communication in Virtual Worlds

    Science.gov (United States)

    Wadley, Greg; Gibbs, Martin R.

    This chapter summarizes 5 years of research on the implications of introducing voice communication systems to virtual worlds. Voice introduces both benefits and problems for players of fast-paced team games, from better coordination of groups and greater social presence of fellow players on the positive side, to negative features such as channel congestion, transmission of noise, and an unwillingness by some to use voice with strangers online. Similarly, in non-game worlds like Second Life, issues related to identity and impression management play important roles, as voice may build greater trust that is especially important for business users, yet it erodes the anonymity and ability to conceal social attributes like gender that are important for other users. A very different mixture of problems and opportunities exists when users conduct several simultaneous conversations in multiple text and voice channels. Technical difficulties still exist with current systems, including the challenge of debugging and harmonizing all the participants' voice setups. Different groups use virtual worlds for very different purposes, so a single modality may not suit all.

  17. Automatic Voltage Control (AVC) of Danish Transmission System - Concept design

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Lund, P.

    2014-01-01

    , objectives, constraints, algorithms for optimal power flow and some special functions in particular systems, which inspires the concept design of a Danish AVC system to address the future challenges of voltage control. In the concept, the Danish AVC design is based on a centralized control scheme. All....... Another consequence is the public way of generally thinking green which have led to a national decision of undergrounding not only all of the Danish distribution system but also the future transmission system. These issues initiate the infrastructure constructions of the transmission system i.e. a large...... the substation loses the telecommunications to the control center. RPCs will be integrated to the AVC system as normative regulators in the later stage. Distributed generation units can be organized as virtual power plants and participate in voltage control at transmission level. Energinet.dk as the Danish TSO...

  18. A Systemic Functional Approach to the Passive Voice in English into Spanish Translation: Thematic Development in a Medical Research Article

    Directory of Open Access Journals (Sweden)

    Rodríguez-Vergara Daniel

    2017-01-01

    Full Text Available The purpose of this study was to explore, from the perspective of Systemic Functional Grammar, how passive clauses in a medical research article were translated into Spanish, specifically if they were kept in the passive voice, were changed into the active voice, or were turned into some other structure, and if voice change in the translated version affected the original thematic development. The medical paper chosen for this study was originally written in English and published in an Anglophone journal; it was then translated into Spanish and published in a Mexican journal. Both the original and the translated article were analyzed in terms of Theme and Rheme; all of the instances of passive and active voice were quantified and compared. The results show that in some cases the original thematic patterns were modified in the translation due to the use of the reflexive passive in Spanish, which results in the fronting of the verb in the sentences, thereby causing a change of Themes in the paragraphs with respect to the original structure. This study contributes to our understanding of the function of passive constructions in English and Spanish and its relationship with thematic progression.

  19. A linear signal transmission system calibration method of wideband GPR

    Science.gov (United States)

    Wu, Bin; Zhao, Kai; Gu, Ling-jia; Cao, Qiong; Li, Xiao-feng; Zheng, Xing-ming

    2016-09-01

    In VHF pulse Ground Penetrating Radar(GPR) system, the echo pass through the antenna and transmission line circuit, then reach the GPR receiver. Thus the reflection coefficient at the receiver sampling gate interface, which is at the end of the transmission line, is different from the real reflection coefficient of the media at the antenna interface, which could cause the GPR receiving error. The pulse GPR receiver is a wideband system that can't be simply described as traditional narrowband transmission line model. Since the GPR transmission circuit is a linear system, the linear transformation method could be used to analyze the characteristic of the GPR receiving system. A GPR receiver calibration method based on transmission line theory is proposed in this paper, which analyzes the relationship between the reflection coefficients of theory calculation at antenna interface and the measuring data by network analyzer at the sampling gate interface. Then the least square method is introduced to calibrate the transfer function of the GPR receiver transmission circuit. This calibration method can be useful in media quantitative inversion by GPR. When the reflection coefficient at the sampling gate is obtained, the real reflection coefficient of the media at the antenna interface can be easily determined.

  20. Optimal Transmission Power in a Nonlinear VLC System

    Institute of Scientific and Technical Information of China (English)

    ZHAO Shuang; CAI Sunzeng; KANG Kai; QIAN Hua

    2016-01-01

    In a visible light communication (VLC) system, the light emitting diode (LED) is nonlinear for large signals, which limits the trans⁃mission power or equivalently the coverage of the VLC system. When the input signal amplitude is large, the nonlinear distortion creates harmonic and intermodulation distortion, which degrades the transmission error vector magnitude (EVM). To evaluate the impact of nonlinearity on system performance, the signal to noise and distortion ratio (SNDR) is applied, defined as the linear sig⁃nal power over the thermal noise plus the front end nonlinear distortion. At a given noise level, the optimal system performance can be achieved by maximizing the SNDR, which results in high transmission rate or long transmission range for the VLC system. In this paper, we provide theoretical analysis on the optimization of SNDR with a nonlinear Hammerstein model of LED. Simula⁃tion results and lab experiments validate the theoretical analysis.

  1. IDNX系统在传输网络中的应用%Applications of IDNX System in Transmission Networks

    Institute of Scientific and Technical Information of China (English)

    张辉

    2001-01-01

    通信网络的数字化得到了越来越广泛的应用。由IDNX系统组成的传输网络平台,可以支持各种通信协议标准。具有组网灵活,结构简单,扩容方便,维护容易的特点。应用语音压缩,数据传输技术,实现语音及数据同时兼容,最大限度地开拓网络资源。%The digital communication networks have been applied more and more. The transmission network platform with IDNX system can support various communication protocol standards. The network platform is flexible to build up. It has a simple structure, a convenient extension, and an easy maintenance.It is compatible with voice and data by using the voice compression and data transmission technology.The network resource can be exploited as greatly as possible.

  2. Design of UAV high resolution image transmission system

    Science.gov (United States)

    Gao, Qiang; Ji, Ming; Pang, Lan; Jiang, Wen-tao; Fan, Pengcheng; Zhang, Xingcheng

    2017-02-01

    In order to solve the problem of the bandwidth limitation of the image transmission system on UAV, a scheme with image compression technology for mini UAV is proposed, based on the requirements of High-definition image transmission system of UAV. The video codec standard H.264 coding module and key technology was analyzed and studied for UAV area video communication. Based on the research of high-resolution image encoding and decoding technique and wireless transmit method, The high-resolution image transmission system was designed on architecture of Android and video codec chip; the constructed system was confirmed by experimentation in laboratory, the bit-rate could be controlled easily, QoS is stable, the low latency could meets most applied requirement not only for military use but also for industrial applications.

  3. Tidal current turbine based on hydraulic transmission system

    Institute of Scientific and Technical Information of China (English)

    Hong-wei LIU; Wei LI; Yong-gang LIN; Shun MA

    2011-01-01

    Tidal current turbines (TCTs) are newly developed electricity generating devices.Aiming at the stabilization of the power output of TCTs,this paper introduces the hydraulic transmission technologies into TCTs.The hydrodynamics of the turbine was analyzed at first and its power output characteristics were predicted.A hydraulic power transmission system and a hydraulic pitch-controlled system were designed.Then related simulations were conducted.Finally,a TCT prototype was manufactured and tested in the workshop.The test results have confirmed the correctness of the current design and availability of installation of the hydraulic system in TCTs.

  4. FPGA Implementation of Video Transmission System Based on LTE

    Directory of Open Access Journals (Sweden)

    Lu Yan

    2015-01-01

    Full Text Available In order to support high-definition video transmission, an implementation of video transmission system based on Long Term Evolution is designed. This system is developed on Xilinx Virtex-6 FPGA ML605 Evaluation Board. The paper elaborates the features of baseband link designed in Xilinx ISE and protocol stack designed in Xilinx SDK, and introduces the process of setting up hardware and software platform in Xilinx XPS. According to test, this system consumes less hardware resource and is able to transmit bidirectional video clearly and stably.

  5. Modern Systems of Information Transmission on Agro & Food Supply Chain

    Directory of Open Access Journals (Sweden)

    Silvius STANCIU

    2011-11-01

    Full Text Available Global food commodity diversification requires the application of new methods of data identification, monitoring, collection and processing in the production or distribution area. Classical systems of information transmission are currently widely used, but also present some inconvenience addressed by the emergence of new generations of information carriers. Current requirements for technical processes monitoring, quality assurance, traceability and customer orientation led to the emergence and evolution of modern identification systems based on dynamic information transmission and global databases development. The development of computer technology and the Internet are factors that allowed the development of these systems.

  6. Subcarrier multiplexing tolerant dispersion transmission system employing optical broadband sources.

    Science.gov (United States)

    Grassi, Fulvio; Mora, José; Ortega, Beatriz; Capmany, José

    2009-03-16

    This paper presents a novel SCM optical transmission system for next-generation WDM-PONs combining broadband optical sources and a Mach-Zehnder interferometric structure. The approach leeds to transport RF signals up to 50 GHz being compatible with RoF systems since a second configuration has been proposed in order to overcome dispersion carrier suppression effect using DSB modulation. The theoretical analysis validates the potentiality of the system also considering the effects of the dispersion slope over the transmission window.

  7. Load flow computations in hybrid transmission - distributed power systems

    NARCIS (Netherlands)

    Wobbes, E.D.; Lahaye, D.J.P.

    2013-01-01

    We interconnect transmission and distribution power systems and perform load flow computations in the hybrid network. In the largest example we managed to build, fifty copies of a distribution network consisting of fifteen nodes is connected to the UCTE study model, resulting in a system consisting

  8. VLBI data transmission system using multiple IP streams

    Science.gov (United States)

    Uose, Hisao

    We have developed an IP-based data transmission system which can directly replace K4 (ID1) VLBI data recorder. It employs multiple TCP data steams and individual buffers to cope with variable usable bandwidth we encouter when we use shared academic networks. This paper describes the outline of the system and preliminary testing results.

  9. Application of AI techniques to a voice-actuated computer system for reconstructing and displaying magnetic resonance imaging data

    Science.gov (United States)

    Sherley, Patrick L.; Pujol, Alfonso, Jr.; Meadow, John S.

    1990-07-01

    To provide a means of rendering complex computer architectures languages and input/output modalities transparent to experienced and inexperienced users research is being conducted to develop a voice driven/voice response computer graphics imaging system. The system will be used for reconstructing and displaying computed tomography and magnetic resonance imaging scan data. In conjunction with this study an artificial intelligence (Al) control strategy was developed to interface the voice components and support software to the computer graphics functions implemented on the Sun Microsystems 4/280 color graphics workstation. Based on generated text and converted renditions of verbal utterances by the user the Al control strategy determines the user''s intent and develops and validates a plan. The program type and parameters within the plan are used as input to the graphics system for reconstructing and displaying medical image data corresponding to that perceived intent. If the plan is not valid the control strategy queries the user for additional information. The control strategy operates in a conversation mode and vocally provides system status reports. A detailed examination of the various AT techniques is presented with major emphasis being placed on their specific roles within the total control strategy structure. 1.

  10. Voice Activity Detector of Wake-Up-Word Speech Recognition System Design on FPGA

    Directory of Open Access Journals (Sweden)

    Veton Z. Këpuska

    2014-12-01

    Full Text Available A typical speech recognition system is push-to-talk operated that requires activation. However for those who use hands-busy applications, movement may by restricted or impossible. One alternative is to use Speech-Only Interface. The proposed method that is called Wake-Up-Word Speech Recognition (WUW-SR that utilizes speech only interface. A WUW-SR system would allow the user to activate systems (Cell phone, Computer, etc. with only speech commands instead of manual activation. The trend in WUW-SR hardware design is towards implementing a complete system on a single chip intended for various applications. This paper presents an experimental FPGA design and implementation of a novel architecture of a real time feature extraction processor that includes: Voice Activity Detector (VAD, and features extraction, MFCC, LPC, and ENH_MFCC. In the WUW-SR system, the recognizer front-end with VAD is located at the terminal which is typically connected over a data network(e.g., serverfor remote back-end recognition. VAD is responsible for segmenting the signal into speech-like and non-speech-like segments. For any given frame VAD reports one of two possible states: VAD_ON or VAD_OFF. The back-end is then responsible to score the features that are being segmented during VAD_ON stage. The most important characteristic of the presented design is that it should guarantee virtually 100% correct rejection for non-WUW (out of vocabulary words - OOV while maintaining correct acceptance rate of 99.9% or higher (in vocabulary words - INV. This requirement sets apart WUW-SR from other speech recognition tasks because no existing system can guarantee 100% reliability by any measure.

  11. A Load-balance and EEDF based strategy for reducing transmission delay of VoIP services in IEEE 802.16e system

    Institute of Scientific and Technical Information of China (English)

    Wang Lilei; Xu Huimin

    2009-01-01

    To decrease the transmission delay of uplink voice over IP (VoIP) services in IEEE 802.16e system, a novel strategy which includes a load-balance algorithm and an extended earliest deadline first (EEDF) scheduling algorithm is proposed. Subsequently, this paper analyzes the performance of the proposed strategy in terms of transmission delay of VoIP services, system capacity, throughput and compatibility with IEEE 802.16e standard. Finally, simulation experiments are carried out to verify the improvement of the proposed strategy. The simulation results match well with the theoretical analysis and show that the proposed strategy reduces the transmission delay of uplink VoIP services and improves the capacity and throughput. These improvements are remarkable especially when the load of system is heavy.

  12. Cryogenic System for a High Temperature Superconducting Power Transmission Cable

    Energy Technology Data Exchange (ETDEWEB)

    Demko, J.A.; Gouge, M.J.; Hughey, R.L.; Lue, J.W.; Martin, R.; Sinha, U.; Stovall, J.P.

    1999-07-12

    High-temperature superconducting (HTS) cable systems for power transmission are under development that will use pressurized liquid nitrogen to provide cooling of the cable and termination hardware. Southwire Company and Oak Ridge National Laboratory have been operating a prototype HTS cable system that contains many of the typical components needed for a commercial power transmission application. It is being used to conduct research in the development of components and systems for eventual commercial deployment. The cryogenic system was built by Air Products and Chemicals, Allentown, Pennsylvania, and can circulate up to 0.35 kg/s of liquid nitrogen at temperatures as low as 67 K at pressures of 1 to 10 bars. Sufficient cooling is provided for testing a 5-m-long HTS transmission cable system that includes the terminations required for room temperature electrical connections. Testing of the 5-m HTS transmission cable has been conducted at the design ac conditions of 1250 A and 7.5 kV line to ground. This paper contains a description of the essential features of the HTS cable cryogenic system and performance results obtained during operation of the system. The salient features of the operation that are important in large commercial HTS cable applications will be discussed.

  13. 基于单片机的语音遥控硬件系统设计%Design of Voice Remote Hardware System Based on Single-chip

    Institute of Scientific and Technical Information of China (English)

    刘宏章

    2011-01-01

    红外线遥控就是利用红外线传递控制信号,实现对控制对象的远距离控制。系统以AT89S52单片机为核心控制器实现红外线遥控语音录放功能,主要由红外发射部分、红外接收及单片机控制部分、液晶显示部分和语音录放部分组成,并且提供红外线遥控和近距离机械按键两种系统操作方式,同时带有实时显示系统工作状态的液晶显示功能,能实现对音频信号进行高保真度的录放过程。%Infrared remote control is the use of infrared transmission control signal,the remote control of the control object.As AT89S52 for the core of the system to design infrared remote controller for voice recording function.It mainly contains the IR transmitter,IR receiver and single-chip control part,liquid crystal display part and the voice recording components and provides close mechanical key and infrared remote control for two systems operate way,while working with a real-time display system status LCD display,can achieve high-fidelity audio signal recording process.

  14. Technology for extending transmission distance of EPON system

    Institute of Scientific and Technical Information of China (English)

    Li ZHANG; Deming LIU; Cbuanbao ZHANG; Guangsbeng WU

    2009-01-01

    At present, the maximal transmission distance between the optical line terminal (OLT) and opticalnetwork unit (ONU) of an Ethemet passive optical network (EPON) system is 20 km.However, this distance should be extended to 50 km or even longer in some applications such as fiber to the village (FTTV).A method for extending the transmission distance of an EPON system is proposed in this paper, in which the optical power amplifier and the adjustment of dynamic bandwidth allocation (DBA) are the key technologies.

  15. Stokes Space in Direct-Detection Data Transmission Systems

    DEFF Research Database (Denmark)

    Estaran Tolosa, Jose Manuel; Lu, Xiaofeng; Zibar, Darko;

    2015-01-01

    Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context.......Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context....

  16. A self-teaching image processing and voice-recognition-based, intelligent and interactive system to educate visually impaired children

    Science.gov (United States)

    Iqbal, Asim; Farooq, Umar; Mahmood, Hassan; Asad, Muhammad Usman; Khan, Akrama; Atiq, Hafiz Muhammad

    2010-02-01

    A self teaching image processing and voice recognition based system is developed to educate visually impaired children, chiefly in their primary education. System comprises of a computer, a vision camera, an ear speaker and a microphone. Camera, attached with the computer system is mounted on the ceiling opposite (on the required angle) to the desk on which the book is placed. Sample images and voices in the form of instructions and commands of English, Urdu alphabets, Numeric Digits, Operators and Shapes are already stored in the database. A blind child first reads the embossed character (object) with the help of fingers than he speaks the answer, name of the character, shape etc into the microphone. With the voice command of a blind child received by the microphone, image is taken by the camera which is processed by MATLAB® program developed with the help of Image Acquisition and Image processing toolbox and generates a response or required set of instructions to child via ear speaker, resulting in self education of a visually impaired child. Speech recognition program is also developed in MATLAB® with the help of Data Acquisition and Signal Processing toolbox which records and process the command of the blind child.

  17. A Proposal on Low Frequency AC Transmission as a Multi-Terminal Transmission System

    Directory of Open Access Journals (Sweden)

    Achara Pichetjamroen

    2016-08-01

    Full Text Available This paper is focused on the discussion and comparison of characteristics and behavior of three low frequency ac (LFAC transmission system configurations operating under the same control scheme and conditions to identify the most promising operation system for LFAC. Merits of LFAC over high voltage direct current (HVDC are mentioned first. By changing power flow direction without auxiliary switches in multi-terminal application and easiness of short circuit protection are explained. The three configurations of LFACs are described and applied by the control scheme with the aid of the tool of the PSCAD/EMTDC software to consider the behavior of each LFAC system on line frequency and low frequency sides. For two-phase system, no fluctuation occurs on the line frequency side, which is the advantage over single-phase system. Furthermore, current rating on thyristor devices during operation and number of devices that used in each type of LFAC are calculated and compared. These results can lead to determine the most suitable transmission system for the LFAC system operation.

  18. Power Transmission System Vulnerability Assessment Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    E. Karimi

    2012-11-01

    Full Text Available Recent blackouts in power systems have shown the necessity of vulnerability assessment. Among all factors, transmission system components have a more important role. Power system vulnerability assessment could capture cascading outages which result in large blackouts and is an effective tool for power system engineers for defining power system bottlenecks and weak points. In this paper a new method based on fault chains concept is developed which uses new measures. Genetic algorithm with an effective structure is used for finding vulnerable branches in a practical power transmission system. Analytic hierarchy process is a technique used to determine the weighting factors in fitness function of genetic algorithm. Finally, the numerical results for Isfahan Regional Electric Company are presented which verifies the effectiveness and precision of the proposed method according to the practical expriments.

  19. A New Design of Video Streaming Capture and Transmission System

    Directory of Open Access Journals (Sweden)

    Xingyu Geng

    2014-10-01

    Full Text Available Aiming to solve some existing problems such as low video streaming rate, high cost and complex set-up, a new video streaming capture and transmission system based on servfox is proposed. This system uses servfox to invoke V4L APIs to capture video streaming in Linux operating system, and then transmits the data to a remote monitoring client through Internet which can display the video streaming. Remote client can be either a software or a web browser. The experimental results show that the image captured by this system is high-quality and the streaming rate is high. At the same time, the system possesses high reliability and low cost. Compared with existing methods, this system can be widely used in the process of video streaming capture and transmission

  20. Reliability Analysis of Random Vibration Transmission Path Systems

    Directory of Open Access Journals (Sweden)

    Wei Zhao

    2017-01-01

    Full Text Available The vibration transmission path systems are generally composed of the vibration source, the vibration transfer path, and the vibration receiving structure. The transfer path is the medium of the vibration transmission. Moreover, the randomness of transfer path influences the transfer reliability greatly. In this paper, based on the matrix calculus, the generalized second moment technique, and the stochastic finite element theory, the effective approach for the transfer reliability of vibration transfer path systems was provided. The transfer reliability of vibration transfer path system with uncertain path parameters including path mass and path stiffness was analyzed theoretically and computed numerically, and the correlated mathematical expressions were derived. Thus, it provides the theoretical foundation for the dynamic design of vibration systems in practical project, so that most random path parameters can be considered to solve the random problems for vibration transfer path systems, which can avoid the system resonance failure.

  1. Medical data transmission system for remote healthcare centres

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, E A; Cagnolo, F J; Olmos, C E; Centeno, C A; Riva, G G; Zerbini, C A [Clinical Engineering Group, National Technological University, Cordoba Regional Faculty, Maestro M Lopez St and Cruz Roja Argentina St, Cordoba (Argentina)

    2007-11-15

    The main motivation of this project is to improve the healthcare centres equipment and human resources efficiency, enabling those centres for transmission of parameters of medical interest. This system facilitates remote consultation, in particular between specialists and remote healthcare centres. Likewise it contributes to the qualification of professionals. The electrocardiographic (ECG) and electroencephalographic (EEG) signals are acquired, processed and then sent, fulfilling the effective norms, for application in the hospital network of Cordoba Province, which has nodes interconnected by phone line. As innovative aspects we emphasized the low cost of development and maintenance, great versatility and handling simplicity with a modular design for interconnection with diverse data transmission media (Wi-Fi, GPRS, etc.). Successfully experiences were obtained during the acquisition of the signals and transmissions on wired LAN networks. As improvements, we can mention: energy consumption optimization and mobile communication systems usage, in order to offer more autonomy.

  2. Impedance matching wireless power transmission system for biomedical devices.

    Science.gov (United States)

    Lum, Kin Yun; Lindén, Maria; Tan, Tian Swee

    2015-01-01

    For medical application, the efficiency and transmission distance of the wireless power transfer (WPT) are always the main concern. Research has been showing that the impedance matching is one of the critical factors for dealing with the problem. However, there is not much work performed taking both the source and load sides into consideration. Both sides matching is crucial in achieving an optimum overall performance, and the present work proposes a circuit model analysis for design and implementation. The proposed technique was validated against experiment and software simulation. Result was showing an improvement in transmission distance up to 6 times, and efficiency at this transmission distance had been improved up to 7 times as compared to the impedance mismatch system. The system had demonstrated a near-constant transfer efficiency for an operating range of 2cm-12cm.

  3. Different Types of Coding Input Data In Optical Transmission Systems

    Directory of Open Access Journals (Sweden)

    Ján Ružbarský

    2016-12-01

    Full Text Available Optical fiber transmission systems are currently the most widely used transmission media. Their development in time had improved their characteristics to such an extent that they gradually replaced very popular copper cable connections. Inspite of that optical fibers still have not reached perfection and constant improvement is needed. Apart from notable advantages such as large data transfer, few numbers of repeaters required on the transmission path or higher safety of transmitted data, optical fiber has also drawbacks that include not sufficient purity optical fibers, fiber fragility and also higher proclivity to nonlinear effects. Weaknesses of optical systems can be depressed by e.g. a selection of an appropriate laser, a proper combination of materials used for fiber production during the manufacture process, or even by using an encryption of transmitted data. This article is focused on the comparison of optical signal properties in various source encoding types of input data.

  4. Guidelines for transient analysis in water transmission and distribution systems

    OpenAIRE

    Pothof, Ivo; Karney, Bryan

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent, monitor and mitigate water losses in water transmission and distribution systems. One of the causes of water losses are transient phenomena, caused by normal and accidental pump and valve operations. ...

  5. Advanced coding techniques for few mode transmission systems.

    Science.gov (United States)

    Okonkwo, Chigo; van Uden, Roy; Chen, Haoshuo; de Waardt, Huug; Koonen, Ton

    2015-01-26

    We experimentally verify the advantage of employing advanced coding schemes such as space-time coding and 4 dimensional modulation formats to enhance the transmission performance of a 3-mode transmission system. The performance gain of space-time block codes for extending the optical signal-to-noise ratio tolerance in multiple-input multiple-output optical coherent spatial division multiplexing transmission systems with respect to single-mode transmission performance are evaluated. By exploiting the spatial diversity that few-mode-fibers offer, with respect to single mode fiber back-to-back performance, significant OSNR gains of 3.2, 4.1, 4.9, and 6.8 dB at the hard-decision forward error correcting limit are demonstrated for DP-QPSK 8, 16 and 32 QAM, respectively. Furthermore, by employing 4D constellations, 6 × 28Gbaud 128 set partitioned quadrature amplitude modulation is shown to outperform conventional 8 QAM transmission performance, whilst carrying an additional 0.5 bit/symbol.

  6. Perturbation Measures of Voice: A Comparative Study between Multi-Dimensional Voice Program and Praat

    National Research Council Canada - National Science Library

    Maryn, Youri; Corthals, Paul; De Bodt, Marc; Van Cauwenberge, Paul; Deliyski, Dimitar

    2009-01-01

    .... In the present study, perturbation measures provided by two computer systems (a purpose-built professional voice analysis apparatus and a personal computer-based system for acoustic voice assessment...

  7. WIFI-based Telephone Voice Monitoring System%基于WIFI的电话语音监控系统

    Institute of Scientific and Technical Information of China (English)

    苏建志; 杨惠山

    2016-01-01

    设计一种新型的基于 WIFI无线的电话语音监控系统,该系统通过士兰微公司的主控芯片 SC6138对电话语音进行采集录音,利用 SD卡、U盘等存储媒介对电话语音信号进行储存,同时通过 WIFI 把储存的语音文件实时传输给远程监控端。首先设计该系统的硬件电路,并详细阐述各个功能模块的工作原理,然后设计主要工作模块的软件及其流程。结果表明,该系统可移动性强,不需要任何主机即可存储语音内容和通过 WIFI 实现远程监控。%The article designed a new wireless telephone voice monitoring system that is based on WIFI module.The sys-tem samples and records the telephone voice by use of main controlling chip SC6138 produced by SiLan Company.The tele-phone voice audio signal is saved as files in SD card and USB.At the same time the voice files stored is transferred live to the remote monitoring terminal through WIFI module when needed.First the hardware circuit of this system is designed and the working principle is elaborated on for each function module of the system.At last the software for the major operational mod-ules and their flow chart are designed.The testing results of the system find that it is of a high mobility and without a host ma-chine it can store voice and be remotely monitored via WIFI.

  8. Control strategies for VSC-based HVDC transmission system

    DEFF Research Database (Denmark)

    Stan, Ana-Irina; Stroe, Daniel Ioan; Silva, Rodrigo Da

    2011-01-01

    the behavior of the developed VSC-based HVDC transmission system two study cases are carried out using MATLAB/Simulink. The results obtained from simulations show acceptable performances, of the proposed strategies, when changes in the reference parameters are considered. The active power flow between...

  9. A CONTACTLESS TRANSMITTER FOR THE M TYPE DATA TRANSMISSION SYSTEM.

    Science.gov (United States)

    A contactless transmitter employing electromagnetic principles for the M type data transmission system is described. It could be contained in a size 11 standard housing if the six semiconductor main switches are mounted externally. Tests showed that the transmitter will operate satisfactorily at speeds in excess of 3000 rev/min, and that it could form the basis of a brushless dc motor . (Author)

  10. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with Ac Cables) research project. The main topics are discussed...

  11. A development of ITV system for power transmission line monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hong Keun; Kim, Seok Ku; Lee, Kwang Joong; Lee, Won Bin [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    Transmission lines which are important to supply the electricity installed on the terrestrially severe site such as mountains needed to be monitored to prevent electric fault by snow accelerating, icing, tree contact, fire etc. Inspections by human patrol has been done but it seems not so efficient and satisfiable. To cope with this a transmission line monitoring system using industrial television and OPGW was developed and field trilled at the site. This paper describes about the optical video transceiver, video distributor and control devices (author).

  12. Keeping Your Voice Healthy

    Science.gov (United States)

    ... Find an ENT Doctor Near You Keeping Your Voice Healthy Keeping Your Voice Healthy Patient Health Information ... heavily voice-related. Key Steps for Keeping Your Voice Healthy Drink plenty of water. Moisture is good ...

  13. Selective transmission and channel estimation in massive MIMO systems

    Institute of Scientific and Technical Information of China (English)

    杨睿哲

    2016-01-01

    Massive MIMO systems have got extraordinary spectral efficiency using a large number of base station antennas, but it is in the challenge of pilot contamination using the aligned pilots.To address this issue, a selective transmission is proposed using time-shifted pilots with cell grouping, where the strong interfering users in downlink transmission cells are temporally stopped during the pilots transmission in uplink cells.Based on the spatial characteristics of physical channel models, the strong interfering users are selected to minimize the inter-cell interference and the cell grouping is designed to have less temporally stopped users within a smaller area.Furthermore, a Kalman estima-tor is proposed to reduce the unexpected effect of residual interferences in channel estimation, which exploits both the spatial-time correlation of channels and the share of the interference information. The numerical results show that our scheme significantly improves the channel estimation accuracy and the data rates.

  14. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research......This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students...... researching electrical engineering topics related to using underground cables for power transmission at EHV level and including the 420 kV level. The research topics were laid down by ET/AAU and Energinet.dk in the DANPAC (DANish Power systems with AC Cables) research project. The main topics are discussed...

  15. Fast isolation of faults in transmission systems using current transients

    Energy Technology Data Exchange (ETDEWEB)

    Perera, N.; Rajapakse, A.D. [University of Manitoba, Department of Electrical and Computer Engineering, Engineering Building, 15 Gillson Street, Winnipeg, Manitoba (Canada)

    2008-09-15

    This paper presents a protection scheme that is capable of very fast isolation of faults in high voltage transmission systems. Proposed scheme comprises set of relays connected through a telecommunication network, located at different nodes of the system. Relays use wavelet coefficients of current signals to identify the fault directions relative to their location. Fault directions identified at different locations in the system can be combined to determine the faulted line (or busbar) and isolate it. A robust single ended traveling wave based fault distance estimation approach is proposed as a backup in case of communication failure. Investigations were carried out using time domain simulations in PSCAD/EMTDC for a high voltage transmission system. (author)

  16. A basic study on application of voice recognition input to an electronic nursing record system -evaluation of the function as an input interface-.

    Science.gov (United States)

    Marukami, Terutaka; Tani, Shoko; Matsuda, Atsuko; Takemoto, Keiko; Shindo, Akiko; Inada, Hiroshi

    2012-06-01

    As computerization in the nursing field has been recently progressing, an electronic nursing record system is gradually introduced in the medical institution in Japan. Although it is expected for the electronic nursing record system to reduce the load of nursing work, the conventional keyboard operation is used for information input of the present electronic nursing record system and it has some problems concerning the input time and the operationability for common nurses who are unfamiliar with the computer operation. In the present study, we conducted a basic study on application of voice recognition input to an electronic nursing record system. The voice input is recently introduced to an electronic medical record system in a few clinics. However, so far the entered information cannot be processed because the information of the medical record must be entered as a free sentence. Therefore, we contrived a template for an electronic nursing record system and introduced it to the system for simple information entry and easy processing of the entered information in this study. Furthermore, an input experiment for evaluation of the voice input with the template was carried out by voluntary subjects for evaluation of the function as an input interface of an electronic nursing record system. The results of the experiment revealed that the input time by the voice input is obviously fast compared with that by the keyboard input and operationability of the voice input was superior to the keyboard input although all subjects had inexperience of the voice input. As a result, it was suggested our method, the voice input using the template made by us, might be useful for an input interface of an electronic nursing record system.

  17. 读书机器人变声系统的研制%A Voice Modification System for Book Reading Robot

    Institute of Scientific and Technical Information of China (English)

    邓杰; 房宁; 赵群飞

    2012-01-01

    为了增加读书机器人(JoyTon)朗读声音的多样性,设计了一种基于单一语音库的声音变换系统.将读书机嚣TTS(textto speech)合成出的初始声音分解成声音激励信号和声道滤波嚣信号,并转换到频域进行修改.利用短时傅立叶幅度谱重构激励信号的方法以及通过修改声道滤波器参数的方法来变换音速、音调和音色.修改后的声音激励信号和声道滤波嚣信号被重新合成产生新的声音信号.该变声系统能在不增加语音库容量的情况下使读书机嚣人用丰富多彩的感情和声调朗读.%Voice modification based on single speech database is proposed in order to increase the voice diversity of the book reading robot (JoyTon). The original sounds synthesized by book reading robot's TTS engine are broken down into excitation and vocal tract filter. Both excitation and vocal tract filter are modified in the frequency domain. Excitation reconstruction through short-time Fourier transform magnitude and parameters modification of vocal tract filter are used to achieve tempo, pitch and timbre modification. Modified excitation and modified vocal tract filter are synthesized back to generate new voice signals. This voice modification system makes book reading robot a text with a variety of emotions and tones without extra memory for speech library.

  18. DistFlow Extensions for AC Transmission Systems

    OpenAIRE

    Coffrin, Carleton; Hijazi, Hassan L.; Van Hentenryck, Pascal

    2015-01-01

    Convex relaxations of the power flow equations and, in particular, the Semi-Definite Programming (SDP), Second-Order Cone (SOC), and Convex DistFlow (CDF) relaxations, have attracted significant interest in recent years. Thus far, studies of the CDF model and its connection to the other relaxations have been limited to power distribution systems, which omit several parameters necessary for modeling transmission systems. To increase the applicability of the CDF relaxation, this paper develops ...

  19. Aswan HighDam/Cairo proposed HVDC transmission system

    Directory of Open Access Journals (Sweden)

    Ahmed Y.M.R. Salama

    2014-03-01

    The DC lines can carry more much power with two conductors than the power transmitted using an AC lines with three conductors of the same size. For the given power level, a DC line requires simpler and cheaper towers (From economical point of view, already installed towers for AC system can be used. Also reduced conductor sizes and insulator can be used. The power transmission losses also will be reduced to about two-thirds of the comparable AC system. The absence of skin effect with DC is also beneficial in reducing power losses marginally. Due to its fast controllability, HVDC transmission system has full control over transmitted power, an ability to enhance transient and dynamic stability in associated AC networks and can limit fault currents levels in the DC lines.

  20. Productive efficiency in electricity transmission and distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Pollitt, M.G. [Oxford Univ. (United Kingdom)

    1994-09-01

    This paper presents a Data Envelopment Analysis (DEA) and an OLS analysis of productive efficiency (cost efficiency) in 129 electricity transmission and 145 electricity distribution systems operating in the accounting year 1990. The transmission data contains US electric systems while the distribution data includes 136 US and 9 UK companies. The paper tests the null hypothesis that privately owned and publicly owned electricity systems do not have significantly different costs. The results of the analysis indicate two things: firstly, a strong inability to reject the null hypothesis in favour of the alternative hypothesis that privately owned firms are more efficient; and secondly, a relatively high level of technical efficiency within the UK companies in the year immediately prior to privatisation. (author)

  1. Design and implementation of E-Kanban voice system based on Wifi%基于Wifi的电子看板语音系统设计实现

    Institute of Scientific and Technical Information of China (English)

    赵慧元; 孙鲁; 苏禹; 彭文亮

    2012-01-01

    E-Kanban widely used in Industrial production areas The paper introduce a new type E-Kanban. compared with traditional one , the system Add IC card authentication, video monitoring, voice call functions, among them the voice call enhance the work field management, and voice broadcast is also implementation, it can provide real time voice training. The function consists of two parts-position machine and embedded system, voice is compressed by adpcm and transferred by wifi. Through testing, the voice is clear and no delay.%电子看版广泛的应用到工业生产领域,文中介绍了一种新型基于arm嵌入式的工业电子看板。和传统的电子看板系统相比,增加了刷卡认证、视频监控、语音通话。其中语音通话增强现场的管理,并能实现广播,给现场人员提供实时培训等功能。语音系统包括上位机及嵌入式两部分组成,语音采用adpcm进行压缩并通过wifi传输,通过测试语音输出清晰、没有延迟。

  2. Transmission dispatch and congestion management in open market systems

    Science.gov (United States)

    Fang, Risheng

    This thesis is located in the domain of electricity supply industry restructuring. It deals with emerging issues, whose understanding is essential to advancing knowledge of open access transmission theory and proceeds to develop approaches for solving the transmission dispatch and congestion management problem. An overview of current trends and experiences in utility restructuring and the main models for restructuring, as well as the classifications of system operators, is first presented. A fully unbundled competitive electricity market model, called the bilateral/multilateral trades model, is then developed. A survey of current research in transmission dispatch and congestion management is included with discussion of transmission capacity and ancillary services. A methodology for the power dispatch problem in a structure dominated by bilateral and multilateral transmission contracts is presented. Group structures are mathematically formulated and explored and three basic types of curtailment strategies proposed for use by market participants. A more complex model is then developed, which takes into account the co-existence of bilateral and multilateral contracts with pool type dynamic supplies and demands based on bids and market clearing prices. An integrated dispatch strategy to reconcile all three types of transactions (bilateral, multilateral and pool) is then developed. Prioritization of electricity transactions and related curtailment strategies are explored and a mechanism for coordination between market participants to achieve additional economic advantages is described. A theory of security based rescheduling is presented in order to investigate the security-related aspects of operation in an unbundled and deregulated system. The impact of post-contingency corrective capability on optimal rescheduling results has been identified and the advantage of incorporating post-contingency corrective rescheduling into the objective function demonstrated. Finally

  3. The transmission link of CAPS navigation and communication system

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The Chinese Area Positioning System (CAPS) is based on communication satellites with integrated capability, which is different from the Global Positioning System (GPS), the International Maritime Satellite Organization (Inmarsat) and so on. CAPS works at C-band, and its navigation information is not directly generated from the satellite, but from the master control station on the ground and transmitted to users via the satellite. The slightly inclined geostationary-satellite orbit (SIGSO) satellites are adopted in CAPS. All of these increase the difficulty in the design of the system and terminals. In this paper, the authors study the CAPS configuration parameters of the navigation master control station, information transmission capability, and the selection of the antenna aperture of the communication center station, as well as the impact of satellite parameters on the whole communication system from the perspective of the transmission link budget. The conclusion of availability of the CAPS navigation system is achieved. The results show that the CAPS inbound communication system forms a new low-data-rate satellite communication system, which can accommodate mass communication terminals with the transmission rate of no more than 1 kbps for every terminal. The communication center station should be configured with a large-aperture antenna (about 10-15 m); spread spectrum com- munication technology should be used with the spreading gain as high as about 40 dB; reduction of the satellite transponder gain attenuation is beneficial to improving the signal-to-noise ratio of the system, with the attenuation value of 0 or 2 dB as the best choice. The fact that the CAPS navigation system has been checked and accepted by the experts and the operation is stable till now clarifies the rationality of the analysis results. The fact that a variety of experiments and applications of the satellite communication system designed according to the findings in this paper have been

  4. Syllogisms delivered in an angry voice lead to improved performance and engagement of a different neural system compared to neutral voice

    Directory of Open Access Journals (Sweden)

    Kathleen Walton Smith

    2015-05-01

    Full Text Available Despite the fact that most real-world reasoning occurs in some emotional context, very little is known about the underlying behavioral and neural implications of such context. To further understand the role of emotional context in logical reasoning we scanned 15 participants with fMRI while they engaged in logical reasoning about neutral syllogisms presented through the auditory channel in a sad, angry, or neutral tone of voice. Exposure to angry voice led to improved reasoning performance compared to exposure to sad and neutral voice. A likely explanation for this effect is that exposure to expressions of anger increases selective attention toward the relevant features of target stimuli, in this case the reasoning task. Supporting this interpretation, reasoning in the context of angry voice was accompanied by activation in the superior frontal gyrus—a region known to be associated with selective attention. Our findings contribute to a greater understanding of the neural processes that underlie reasoning in an emotional context by demonstrating that two emotional contexts, despite being of the same (negative valence, have different effects on reasoning.

  5. 红外无线语音系统的设计与实现%Design and implementation of infrared wireless voice system

    Institute of Scientific and Technical Information of China (English)

    王智伟

    2016-01-01

    Science and technology continues to progress,and all kinds of communication technolgy are also in constant improvement progress.In the system design,I use a wave length of 850nm infrared transmitting and receiving tube.Use it to make sound delivery.Using a plug of the mobile phone as the input singal through the circuit debugging to realize voice signal transmission, so as to realize through tne orientation,and then I design the infrared transceiver system.Through the test and inspection date we can know that the transmission distance is 5m infrared communication to ensure no significant distortion limit distance under the condition of the amplifier and filter circuit.This circuit is mainly composed of LM-386 structures.At the same time, we alse add a conversion device to realize the transformation of 90 degree,the voice of the input can be heard in the horn of the output finally.%本设计制作的这个系统是红外无线语音传输系统.在系统设计时,使用的是一对850nm波长的红外光发射、接收管.利用它能够将声音进行传递.在用手机的插头作为输入信号在通过电路的调试来实现语音信号传输,从而实现了定向,然后我在进行红外光收发系统的设计.通过测试和查阅资料可以知道,5m的传输距离是红外通信保证无明显失真情况下的极限距离.通过放大和滤波电路,此时电路主要由LM-386所搭建.同时我们还加了一个转制装置来实现90°的转变,最后输出端的喇叭中可以听到输入的语音.

  6. Evaluation of an Intelligent Assistive Technology for Voice Navigation of Spreadsheets

    CERN Document Server

    Flood, Derek; Caffery, Fergal Mc; Bishop, Brian

    2008-01-01

    An integral part of spreadsheet auditing is navigation. For sufferers of Repetitive Strain Injury who need to use voice recognition technology this navigation can be highly problematic. To counter this the authors have developed an intelligent voice navigation system, iVoice, which replicates common spreadsheet auditing behaviours through simple voice commands. This paper outlines the iVoice system and summarizes the results of a study to evaluate iVoice when compared to a leading voice recognition technology.

  7. A Multiple-Antenna System for ISM-Band Transmission

    Directory of Open Access Journals (Sweden)

    Rinas J

    2004-01-01

    Full Text Available We present a multiple antenna system for industrial, scientific, and medical (ISM-band transmission (MASI. The hardware demonstrator was developed and realized at our institute. It enables multiple-input multiple-output (MIMO-communication applications and is capable of transmiting arbitrary signals using transmit and receive antennas in parallel. It operates in the 2.4 GHz ISM-band. The hardware concept is introduced and some design specifications are discussed. Using this transmission system, we present some measurement results to show the feasibility of MIMO concepts currently under discussion. The applications include transmit and receive diversity for single carrier and OFDM as well as blind source separation (BSS techniques.

  8. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    Power transmission is facing its largest challenges ever with regards to handling a transition from today’s fossil‐based power production into renewable sources of generation. We can no longer place power plants close to centres of consumption; they must be located where the natural resources...... the role of interconnecting these generation/load centres, ensuring fair reliability and redundancy of supply. Nowadays, the power transmission system must be able to handle the various sources of renewable generation in a flexible electricity market. This has the consequence that the original layout...... cables is given, and secondly, the modelling approach and validation of this is discussed. Thirdly, making up the main core of the work presented, dynamics of underground cable systems are discussed and important cases to study are highlighted, and next, protection and fault location are discussed...

  9. Portable wireless power transmission system for video capsule endoscopy.

    Science.gov (United States)

    Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

    2014-10-01

    Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

  10. Data Acquisition and Transmission System for Building Energy Consumption Monitoring

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    2013-01-01

    Full Text Available Building energy consumption monitoring and management system have been developed widely in China in order to gain the real-time data of energy consumption in buildings for analyzing it in the next state work. This paper describes a low-cost and small-sized collector based on the STM32 microcontroller, which can be placed in a building easily to implement the work of data acquisition, storage, and transmission. The collector gathers the electricity, water, heat, and energy consumption data through the RS485 field bus and stores the data into an SD card with mass storage, finally, using Internet to finish the communication and transmission to data server through TCP protocol. The collector has been used in application for two years, and the results show that the system is reliable and stable.

  11. Adaptive Image Transmission Scheme over Wavelet-Based OFDM System

    Institute of Scientific and Technical Information of China (English)

    GAOXinying; YUANDongfeng; ZHANGHaixia

    2005-01-01

    In this paper an adaptive image transmission scheme is proposed over Wavelet-based OFDM (WOFDM) system with Unequal error protection (UEP) by the design of non-uniform signal constellation in MLC. Two different data division schemes: byte-based and bitbased, are analyzed and compared. Different bits are protected unequally according to their different contribution to the image quality in bit-based data division scheme, which causes UEP combined with this scheme more powerful than that with byte-based scheme. Simulation results demonstrate that image transmission by UEP with bit-based data division scheme presents much higher PSNR values and surprisingly better image quality. Furthermore, by considering the tradeoff of complexity and BER performance, Haar wavelet with the shortest compactly supported filter length is the most suitable one among orthogonal Daubechies wavelet series in our proposed system.

  12. Energy-Efficient Transmission Schemes in Cooperative Cellular Systems

    CERN Document Server

    Yang, Wei; Wang, Ying; Sun, Wanlu

    2010-01-01

    Energy-efficient communication is an important requirement for mobile devices, as the battery technology has not kept up with the growing requirements stemming from ubiquitous multimedia applications. This paper considers energy-efficient transmission schemes in cooperative cellular systems with unbalanced traffic between uplink and downlink. Theoretically, we derive the optimal transmission data rate, which minimizes the total energy consumption of battery-powered terminals per information bit. The energy-efficient cooperation regions are then investigated to illustrate the effects of relay locations on the energy-efficiency of the systems, and the optimal relay location is found for maximum energy-efficiency. Finally, numerical results are provided to demonstrate the tradeoff between energy-efficiency and spectral efficiency.

  13. Rigorous theoretical derivation of lumped models to transmission line systems

    Institute of Scientific and Technical Information of China (English)

    Zhao Jixiang

    2012-01-01

    By virtue of the negative electric parameter concept,i.e.negative lumped resistance,inductance,conductance and capacitance (N-RLGC),the lumped equivalent models of transmission line systems,including the circuit model,two-port π-network and T-network,are given.We start from the N-segment-ladder-like equivalent networks composed distributed parameters,and achieve the input impedance in the form of a continued fraction.Utilizing the continued fraction theory,the expressions of input impedance are obtained under three kinds of extreme cases,i.e.the load impedances are equal to zero,infinity and characteristic impedance,respectively.When the number of segment N is limited to infinity,they are transformed to lumped elements.Comparison between the distributed model and lumped model of transmission lines,the expression of tanh yd,which is the key term in the transmission line equations,are obtained by RLGC,furthermore,according to input admittance,admittance matrix and ABCD matrix of transmission lines,the lumped equivalent circuit models,π-networks and T-networks have been given.The models are verified in the frequency and time domain,respectively,showing that the models are accurate and efficient.

  14. Playful Interaction with Voice Sensing Modular Robots

    DEFF Research Database (Denmark)

    Heesche, Bjarke; MacDonald, Ewen; Fogh, Rune

    2013-01-01

    This paper describes a voice sensor, suitable for modular robotic systems, which estimates the energy and fundamental frequency, F0, of the user’s voice. Through a number of example applications and tests with children, we observe how the voice sensor facilitates playful interaction between...... children and two different robot configurations. In future work, we will investigate if such a system can motivate children to improve voice control and explore how to extend the sensor to detect emotions in the user’s voice....

  15. TRANSMISSION OF DATA USING POWER LINE CARRIER COMMUNICATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Jovita Serrao

    2012-11-01

    Full Text Available This paper serves as a general and technical reference to transmission of data using a power line carrier communication system which is a preferred choice over Wireless or other Home Networking technologies due to the ease of installation, availability of AC outlets, higher throughput, low cost, reliability and security. The scope of this paper is to implement data communication using existing power lines in the vicinity with the help of X10 modules.

  16. A GIS-based Power Transmission Management Information System

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>Based on analyzing the shortcomings of electric power enterprise in traditional operation pattern,this paper combines components GIS with the application of management information system,and uses the structure which unifies three layers C/S and B/S.Also,proposed using the GPS intellectualization patrol.This may be useful to guarantees the transmission line’s operation to be safe and stable.

  17. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    are to be found. One very good example of this is offshore wind power plants. The current transmission system is laid out in a traditional manner, which is based on the idea of not transporting power over longer distances as the power plants have been located near centres of consumption. It has merely played....... Many interesting research topics are still open, especially with regards to asset management tools....

  18. Transmission of order in some unusual dilute systems

    Science.gov (United States)

    Adler, Joan; Palmer, R. G.; Meyer, H.

    1987-03-01

    As a system is diluted, the critical temperature T may fall to zero at a concentration X sub c greater than the percolation concentration, because mere connectivity does not guarantee the transmission of order even at T = 0. Detailed results, including bounds on X sub c, are presented for the three-state Potts antiferromagnet on a triangular lattice and for quadrupolar models of (o-H2)x(p-H2)1-x mixtures on fcc and triangular lattices.

  19. Sustainable Consumer Voices

    DEFF Research Database (Denmark)

    Klitmøller, Anders; Rask, Morten; Jensen, Nevena

    2011-01-01

    Aiming to explore how user driven innovation can inform high level design strategies, an in-depth empirical study was carried out, based on data from 50 observations of private vehicle users. This paper reports the resulting 5 consumer voices: Technology Enthusiast, Environmentalist, Design Lover......, Pragmatist and Status Seeker. Expedient use of the voices in creating design strategies is discussed, thus contributing directly to the practice of high level design managers. The main academic contribution of this paper is demonstrating how applied anthropology can be used to generate insights...... into disruptive emergence of product service systems, where quantitative user analyses rely on historical continuation....

  20. Design of intelligent voice control system based on DSP%基于DSP的智能语音控制系统设计

    Institute of Scientific and Technical Information of China (English)

    郑微; 李正周; 田蕾

    2012-01-01

    利用语音命令实现与智能设备的交互已经成为现代控制理论研究的热门话题之一.介绍了一种基于数字信号处理器(DSP)、语音采集模块、无线收发模块、片上外设等资源实现的语音命令控制处理系统.该系统首先通过语音采集模块采集到语音控制信号;然后通过DSP和相应的片上外设实现对语音命令的识别;最后将识别的语音命令传递给无线收发模块以实现对于智能设备的控制.整个系统的设计应用领域广泛,可以为人机交互提供一种切实可行的参考方案.%Using voice commands to realize the interaction with intelligent equipment has become one of the hot topics in modern control theory. The voice command control processing system based on DSP, voice acquisition module, wireless transceiver module, on-chip peripheral resources is designed and realized. The voice control signals is acquired by the voice acquisition module in the system,and voice commands is recognized by DSP and on-chip peripheral resources, and the identified voice commands is transferred to the wireless transceiver module to control the intelligent equipment. The design application field of the whole system is very wide, and provides a kind of feasible and practical reference for human-computer interaction.

  1. Control and Simulation of Continuously Variable Transmission for Electric Transmission System

    Institute of Scientific and Technical Information of China (English)

    张豫南; 葛蕴珊; 马晓军; 臧克茂

    2004-01-01

    According to the study of electric transmission, the concept of the fore and the aft power chain is presented. The control method of continuously variable transmission is established in the aft chain of electric transmission based on brushless DC motor. A fuzzy controller is designed with continuous fuzzy variables and the simulation module of the aft power chain is proved by test. The fuzzy controller controls the process of continuously variable transmission steadily and the acceleration of vehicle is quick according to simulation results. The elementary performance exhibited in the simulation is a foundation for the further study of the electric transmission track vehicle.

  2. Listen to a voice

    DEFF Research Database (Denmark)

    Hølge-Hazelton, Bibi

    2001-01-01

    Listen to the voice of a young girl Lonnie, who was diagnosed with Type 1 diabetes at 16. Imagine that she is deeply involved in the social security system. She lives with her mother and two siblings in a working class part of a small town. She is at a special school for problematic youth, and he...

  3. What the voice reveals.

    NARCIS (Netherlands)

    Ko, Sei Jin

    2007-01-01

    Given that the voice is our main form of communication, we know surprisingly little about how it impacts judgment and behavior. Furthermore, the modern advancement in telecommunication systems, such as cellular phones, has meant that a large proportion of our everyday interactions are conducted voca

  4. Voices for Careers.

    Science.gov (United States)

    York, Edwin G.; Kapadia, Madhu

    Listed in this annotated bibliography are 502 cassette tapes of value to career exploration for Grade 7 through the adult level, whether as individualized instruction, small group study, or total class activity. Available to New Jersey educators at no charge, this Voices for Careers System is also available for duplication on request from the New…

  5. What the voice reveals

    NARCIS (Netherlands)

    Ko, Sei Jin

    2007-01-01

    Given that the voice is our main form of communication, we know surprisingly little about how it impacts judgment and behavior. Furthermore, the modern advancement in telecommunication systems, such as cellular phones, has meant that a large proportion of our everyday interactions are conducted voca

  6. Downlink transmission in multi-carrier systems with reduced feedback

    DEFF Research Database (Denmark)

    Wang, Yuanye; Pedersen, Klaus; Sørensen, Troels Bundgaard

    2010-01-01

    in this paper we address the problem of reducing the feedback for the downlink transmission in multi-carrier systems. In these systems multiple Component Carriers (CCs) are aggregated together to form a wide spectrum. Consequently, a large feedback overhead is required to report the channel quality...... information over such a wide bandwidth. We first generalize two existing feedback reduction techniques, and then propose a new one. These techniques use different feedback schemes across the CCs, or allow some CCs to be un-reported, for the purpose of reducing the amount of feedback. Performance...

  7. A novel fiber audio transmission system for secure communication

    Institute of Scientific and Technical Information of China (English)

    SU Ke; JIA Bo

    2005-01-01

    A new,simple and efficient fiber audio transmission method for the long distance secure communication is presented, which performs signal modulation by the strain-optic effects and signal demodulation by the all-fiber interferometer. The interferometer is a truly path-matched device, which eliminates much of the undesirable noise by combining the reference and the sensing arms within the same optical fiber. The sinusoidal signals adopted in the experiment are in a frequency range of 300 HZ-3 400 HZ and of the multi-frequency, and the system shows good capabilities, robust security and maintenance of audio integrity. The device may be applicable in the field of point to point secure communication of 40 kilometer long transmission range.

  8. Power and signal transmission for mobile teleoperated systems

    Energy Technology Data Exchange (ETDEWEB)

    Morris, A.C. Jr.; Hamel, W.R.

    1985-01-01

    Appropriate means must be furnished for supplying power and for sending controlling commands to mobile teleoperated systems. Because a sizable number of possibilities are available for such applications, methods used in designing both the power and communications systems built into mobile vehicles that serve in radiological emergencies must be carefully selected. This paper describes a number of umbilical, on-board, and wireless systems used in tranmitting power that are available for mobile teleoperator services. The pros and cons of selecting appropriate methods from a list of possible communication systems (wired, fiber optic, and radio frequency) are also examined. Moreover, hybrid systems combining wireless power transmissions with command-information signals are also possible.

  9. Lightning location system supervising Swedish power transmission network

    Science.gov (United States)

    Melin, Stefan A.

    1991-01-01

    For electric utilities, the ability to prevent or minimize lightning damage on personnel and power systems is of great importance. Therefore, the Swedish State Power Board, has been using data since 1983 from a nationwide lightning location system (LLS) for accurately locating lightning ground strikes. Lightning data is distributed and presented on color graphic displays at regional power network control centers as well as at the national power system control center for optimal data use. The main objectives for use of LLS data are: supervising the power system for optimal and safe use of the transmission and generating capacity during periods of thunderstorms; warning service to maintenance and service crews at power line and substations to end operations hazardous when lightning; rapid positioning of emergency crews to locate network damage at areas of detected lightning; and post analysis of power outages and transmission faults in relation to lightning, using archived lightning data for determination of appropriate design and insulation levels of equipment. Staff have found LLS data useful and economically justified since the availability of power system has increased as well as level of personnel safety.

  10. Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS

    Science.gov (United States)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2012-08-01

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  11. Adaptive transmission schemes for MISO spectrum sharing systems

    KAUST Repository

    Bouida, Zied

    2013-06-01

    We propose three adaptive transmission techniques aiming to maximize the capacity of a multiple-input-single-output (MISO) secondary system under the scenario of an underlay cognitive radio network. In the first scheme, namely the best antenna selection (BAS) scheme, the antenna maximizing the capacity of the secondary link is used for transmission. We then propose an orthogonal space time bloc code (OSTBC) transmission scheme using the Alamouti scheme with transmit antenna selection (TAS), namely the TAS/STBC scheme. The performance improvement offered by this scheme comes at the expense of an increased complexity and delay when compared to the BAS scheme. As a compromise between these schemes, we propose a hybrid scheme using BAS when only one antenna verifies the interference condition and TAS/STBC when two or more antennas are illegible for communication. We first derive closed-form expressions of the statistics of the received signal-to-interference-and-noise ratio (SINR) at the secondary receiver (SR). These results are then used to analyze the performance of the proposed techniques in terms of the average spectral efficiency, the average number of transmit antennas, and the average bit error rate (BER). This performance is then illustrated via selected numerical examples. © 2013 IEEE.

  12. The transmission link of CAPS navigation and communication system

    Institute of Scientific and Technical Information of China (English)

    CUI JunXia; SHI HuLi; CHEN JiBin; PEI Jun

    2009-01-01

    The Chinese Area Positioning System (CAPS) is based on communication satellites with integrated oapability,whioh is different from the Global Positioning System (GPS),the International Maritime Satellite Organization (Inmarsat) and so on.CAPS works at G-band,and its navigation information ie not directly generated from the satellite,but from the master control station on the ground and transmitted to users via the satellite.The slightly inclined geostationary-satellite orbit (SIGSO) satellites are adopted in CAPS.All of these increase the difficulty in the design of the system and terminals.In this paper,the authors study the CAPS oonfiguration parameters of the navigation master control station,information transmission capability,and the selection of the antenna aperture of the communication oenter station,as well as the impact of satellite parameters on the whole communication system from the perspective of the transmission link budget.The conclusion of availability of the GAPS navigation system is achieved.The results show that the GAPS inbound communication system forms a new low-data-rate satellite communicaUon system,which can accommodate mass communication termihale with the transmission rate of no more than 1 kbps for every terminal.The communication center station should be configured with a large-aperture antenna (about 10--15 m); spread spectrum communication technology should be used with the spreading gain as high as about 40 dB; reduction of the satellite transponder gain attenuation is beneficial to improving the signal-to-noise ratio of the system,with the attenuation value of 0 or 2 dB as the best choice.The fact that the GAPS navigation system has been checked and aooepted by the experts and the operation is stable till now larifies the rationality of the analysis results.The fact that a variety of experiments and applications of the satellite communication system designed according to the findings in this paper have been successfully carried out

  13. 智能音控小车系统设计%Design of an Intelligent Voice Trolley System

    Institute of Scientific and Technical Information of China (English)

    曹斌芳; 李建奇; 胡惟文

    2012-01-01

    The design of an intelligent voice vehicle system was introduced,which uses sunplus's microcomputer SPCE061A as the core control portion,and drives chip L298N of electrical motor as the main control modules in the design.According to recorded the voice command the system can control the car to start,stop,return and turn.The run state of the intellectual vehicle shows that the project is feasible.%以凌阳单片机SPCE061A为核心控制部件,电机驱动芯片L298N为主要元件,以语音小车控制电路板为辅,设计并制作了一种智能音控小车系统。该系统能根据录制的语音命令来控制小车的启动、停止、返回、拐弯。智能音控小车的运行状态表明该设计方案是可行的。

  14. Multi-core Fibers in Submarine Networks for High-Capacity Undersea Transmission Systems

    DEFF Research Database (Denmark)

    Nooruzzaman, Md; Morioka, Toshio

    2017-01-01

    Application of multi-core fibers in undersea networks for high-capacity submarine transmission systems is studied. It is demonstrated how different architectures of submerged branching unit affect network component counts in long-haul undersea transmission systems......Application of multi-core fibers in undersea networks for high-capacity submarine transmission systems is studied. It is demonstrated how different architectures of submerged branching unit affect network component counts in long-haul undersea transmission systems...

  15. Design and optimization of voice coil actuator for six degree of freedom active vibration isolation system using Halbach magnet array.

    Science.gov (United States)

    Kim, MyeongHyeon; Kim, Hyunchang; Gweon, Dae-Gab

    2012-10-01

    This paper describes the design, modeling, optimization, and validation of an active vibration isolation system using a voice coil motor. The active vibration isolating method was constructed with a passive isolator and an active isolator. A spring was used for passive isolating; an actuator was used for active isolating. The proposed active vibration isolation system (AVIS) can isolate disturbances for many kinds of instruments. Until now, developed AVIS were able to isolate a six degree-of-freedom disturbance effectively. This paper proposes the realization of such a six degree-of-freedom active vibration isolation system that can work as a bench top device for precision measuring machines such as atomic force microscope, scanning probe microscope, etc.

  16. Generation and transmission of greenhouse gases in river system

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yu; WANG Shu-bo

    2016-01-01

    The research progress on the current domestic and foreign about river water system of the greenhouse gas methane(CH4), and nitrous oxide(N2O) generation, transmission and release mechanism are reviewed in this paper. At present, at home and abroad of river water system of methane production and release of the driving factors and mechanism has been basically clear, but the N2O production mechanism is not clear, multi factor interaction of river water system of N2O production and release of complex, in different regions and time of result differences. The calculation of water flux of N2O river discharge coefficient of river IPCC released based on N2O, the release amount may underestimate the river water N2O.

  17. A portable wireless power transmission system for video capsule endoscopes.

    Science.gov (United States)

    Shi, Yu; Yan, Guozheng; Zhu, Bingquan; Liu, Gang

    2015-01-01

    Wireless power transmission (WPT) technology can solve the energy shortage problem of the video capsule endoscope (VCE) powered by button batteries, but the fixed platform limited its clinical application. This paper presents a portable WPT system for VCE. Besides portability, power transfer efficiency and stability are considered as the main indexes of optimization design of the system, which consists of the transmitting coil structure, portable control box, operating frequency, magnetic core and winding of receiving coil. Upon the above principles, the correlation parameters are measured, compared and chosen. Finally, through experiments on the platform, the methods are tested and evaluated. In the gastrointestinal tract of small pig, the VCE is supplied with sufficient energy by the WPT system, and the energy conversion efficiency is 2.8%. The video obtained is clear with a resolution of 320×240 and a frame rate of 30 frames per second. The experiments verify the feasibility of design scheme, and further improvement direction is discussed.

  18. Use of system approaches for transmission open access pricing

    Energy Technology Data Exchange (ETDEWEB)

    Rudnick, H.; Soto, M.; Palma, R. [Pontificia University Catolica de Chile, Santiago (Chile)

    1999-02-01

    The Latin American deregulated markets have based their open access schemes on a concept that considers a multilateral use of the transmission system, with all agents contributing to the financing of a common network based on physical and economic usage, irrespective of commercial arrangements. The paper describes the concept and the existing schemes and contributes with the formulation of alternative numerical approaches for open access pricing, taking into account energy and capacity use of the system by the participant agents. Distribution factors based on DC power flows are the basic elements of the formulation, which is built based on different physical and economic considerations. The approaches are numerically evaluated in the Chilean main interconnected electrical system, with a comparison of the resultant impacts on generators and consumers. (author)

  19. Carbon footprint of the Danish electricity transmission and distribution systems

    DEFF Research Database (Denmark)

    Turconi, Roberto; Astrup, Thomas Fruergaard

    &D) will likely grow. Several studies are available on renewable energy technologies, but only a few on transmission of electricity, and none on its distribution. This study provides life cycle inventory data for electricity distribution networks, and a life cycle GHG accounting of the Danish T&D networks....... The purpose was to evaluate the potential importance of environmental impacts associated with T&D in current and future electricity systems. Including the emissions from electricity T&D is needed to provide a full carbon footprint of electricity systems, and is essential to properly assess the environmental...... consequences of potential changes in an electricity system. So far, the basis for such assessments has not been available. The functional unit of this study was the delivery of one kWh of electricity in Denmark. The 2010 Danish electricity T&D networks were modeled, including power lines, transformers...

  20. Multi-message Voice Record and Playback System Based on MOU%单片机的多段语音组合录放系统设计

    Institute of Scientific and Technical Information of China (English)

    温洪昌; 黄应强; 傅贵兴

    2011-01-01

    A kind of multi-message voice record and playback system is designed based on MCUSTC89C52RC and voice chip ISD1730, The paper introduces the process realization, including voice circuits design, multi-message voice recording, locating, editing and cornbi nation outputting. Also, a temperature measuring instrument with voice output function is produced. Experiments indicate that this in strument is easier to operate and use.%介绍一种基于单片机STC89C52RC、语音芯片ISD1730组成的多段语音录放系统设计方案。描述了语音电路设计、语音分段录入、语音段定位、语音段剪辑、多段语音组合输出等的实现方法;并制作了一个具有语音输出功能的温度测量仪。实验表明,具有语音输出功能的温度测量仪器更便于操作和使用。

  1. 75 FR 3223 - California Independent System Operator Corporation; Midwest Independent Transmission System...

    Science.gov (United States)

    2010-01-20

    ... a subsequent notice. \\1\\ Wholesale Competition in Regions with Organized Electric Market, Order No... the responsiveness of regional transmission organizations (RTOs) and independent system operators... lead to decisions that do not adequately consider the price of electricity to residential consumers....

  2. A flexible computerized system for environmental data acquisition and transmission

    Science.gov (United States)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  3. Fast Decoupled Power Flow for Power System with High Voltage Direct Current Transmission Line System

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2010-01-01

    Full Text Available Problem statement: High voltage direct current transmission line system has been widely applied for control power flow in power system. The power flow analysis was the one of powerful tools by which the power system equipped was analyzed both for planning and operation strategies. Approach: This study presented the method to analyze power flow of power system consisted of HVDC system. HVDC was modeled as the complex power injections. The presented complex power injected was incorporated into the existing power flow program based on fast decoupled method. The presented method was tested on the multimachine power system. Results: The transmission line loss of the system with and without HVDC was compared. Conclusion: From the simulation results, the HVDC can reduce transmission line loss of power system.

  4. Nonlinear Vibroimpact Characteristics of a Planetary Gear Transmission System

    Directory of Open Access Journals (Sweden)

    Jianxing Zhou

    2016-01-01

    Full Text Available In order to research the vibroimpact characteristics of a planetary gear transmission system under high speed and lightly loaded conditions, a new modeling method is proposed. In the modeling process, linear spring was used to simulate gear mesh elasticity under heavy load cases, and Hertz contact theory was used to calculate the contact force of gear pair under light load cases. Then, effects of the working conditions on the system vibroimpact characteristics are analyzed. The results show that, with input speed growing, the mesh force produced obvious fluctuations on the resonance frequencies of the sun gear and carrier torsion vibration, ring gear’s transverse vibration under the heavy load. Under light load condition, the collision vibration occurs in the gear pair; the changing trend of the contact force shows strongly nonlinear characteristics. The time of mesh-apart in gears pair decreases gradually as the load is increased; until it reaches collision vibration threshold value, the gear pair is no longer mesh-apart. With increasing of the input speed, the time of mesh-apart is decreased gradually; the fluctuation amplitude of contact force shows a linearly increasing trend. The study provides useful theoretical guideline for planetary gear transmission low-noise design.

  5. The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation

    OpenAIRE

    Li Tian; Wenming Wang; Hui Qian

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results sho...

  6. Optimisation of power transmission systems using a discrete Tabu Search method

    OpenAIRE

    Connor, Andy M.; Tilley, Derek G.

    2016-01-01

    This paper presents a brief description of the Tabu Search method and shows how it can be applied to two different power transmission systems. Examples are presented from two transmission systems. In the first example a mechanical transmission system is considered. A four bar mechanism is synthesised in order to produce a desired output motion. The second example is a hydrostatic transmission operating under closed loop control in order to maintain a constant operating speed as the loading co...

  7. Analysis of torsional vibration in an electromechanical transmission system

    Directory of Open Access Journals (Sweden)

    Kai Chen

    2016-06-01

    Full Text Available Aiming at the torsional vibration in the electromechanical transmission system, this article introduces the active vibration method and analyzes the vibration characteristics on the condition of the external excitation, and then, the condition of the permanent magnetic synchronous motor parameter is obtained. In the braking energy recovery working condition, the permanent magnetic synchronous motor is operated in generator mode and is subjected to power control, this cause it to produce negative effect of damping. Negative effect of damping leads to the increasing torsional vibration. Then, the improved power control strategy is introduced to reduce the vibration. Computer simulations are used to demonstrate the active vibration method and the effectiveness of the proposed control strategy, which provides reference for the design of electromechanical systems in the hybrid electrical vehicles.

  8. Dynamic security risk assessment and optimization of power transmission system

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The paper presents a practical dynamic security region (PDSR) based dynamic security risk assessment and optimization model for power transmission system. The cost of comprehensive security control and the influence of uncertainties of power injections are considered in the model of dynamic security risk assessment. The transient stability constraints and uncertainties of power injections can be considered easily by PDSR in form of hyper-box. A method to define and classify contingency set is presented, and a risk control optimization model is given which takes total dynamic insecurity risk as the objective function for a dominant con-tingency set. An optimal solution of dynamic insecurity risk is obtained by opti-mizing preventive and emergency control cost and contingency set decomposition. The effectiveness of this model has been proved by test results on the New Eng-land 10-genarator 39-bus system.

  9. Application of DSP in the image transmission system

    Science.gov (United States)

    Gui, Feng; Wei, LinQi

    2006-05-01

    A scheme to realize static image and video code and decode based on TI DSP chip TMS320C6416 was proposed in this paper, and a reliable image transmission system was developed. According to the application demand, the software has six major modules: (1) initialization of DSP chip and other hardware; (2) video acquisition and input control program; (3) serial port communicating program; (4) RAM storage and communicating program that applies and releases the token-ring; (5) video reconstruct and output control; (6) the major parts of the software, encoding and decoding program, in which wavelet was applied first, then run length coding and Huffman coding were carried out, the image or video could had balance resolution and better visual effect by adaptive processing, in the decoding parts, the reverse operation were executed. After the system line up debugging was carried out, a satisfying result was reached: the comparatively high compression rate, preferable image quality and relatively real-time result.

  10. SURGNET: An Integrated Surgical Data Transmission System for Telesurgery

    Directory of Open Access Journals (Sweden)

    Sriram Natarajan

    2009-01-01

    Full Text Available Remote surgery information requires quick and reliable transmission between the surgeon and the patient site. However, the networks that interconnect the surgeon and patient sites are usually time varying and lossy which can cause packet loss and delay jitter. In this paper we propose SURGNET, a telesurgery system for which we developed the architecture, algorithms and implemented it on a testbed. The algorithms include adaptive packet prediction and buffer time adjustment techniques which reduce the negative effects caused by the lossy and time varying networks. To evaluate the proposed SURGNET system, at the therapist site, we implemented a therapist panel which controls the force feedback device movements and provides image analysis functionality. At the patient site we controlled a virtual reality applet built in Matlab. The varying network conditions were emulated using NISTNet emulator. Our results show that even for severe packet loss and variable delay jitter, the proposed integrated synchronization techniques significantly improve SURGNET performance.

  11. Practical applications of interactive voice technologies: Some accomplishments and prospects

    Science.gov (United States)

    Grady, Michael W.; Hicklin, M. B.; Porter, J. E.

    1977-01-01

    A technology assessment of the application of computers and electronics to complex systems is presented. Three existing systems which utilize voice technology (speech recognition and speech generation) are described. Future directions in voice technology are also described.

  12. System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Muhammad Khan

    2014-01-01

    Full Text Available Use of blood glucose (BG meters in the self-monitoring of blood glucose (SMBG significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation. We conducted a study to determine whether the accuracy of the GlucoRx Nexus TD-4280 meter, utilized by our department for its cost-effectiveness, complied with ISO guidelines. 105 patients requiring laboratory blood glucose analysis were randomly selected and reference measurements were determined by the UniCel DxC 800 clinical system. Overall the BG meter failed to adhere to the ≥95% accuracy criterion required by both the 15197:2003 (overall accuracy 92.4% and 15197:2013 protocol (overall accuracy 86.7%. Inaccurate meters have an inherent risk of over- and/or underestimating the true BG concentration, thereby risking patients to incorrect therapeutic interventions. Our study demonstrates the importance of internally validating the accuracy of BG meters to ensure that its accuracy is accepted by standardized guidelines.

  13. Voice Quality Estimation in Wireless Networks

    Directory of Open Access Journals (Sweden)

    Petr Zach

    2015-01-01

    Full Text Available This article deals with the impact of Wireless (Wi-Fi networks on the perceived quality of voice services. The Quality of Service (QoS metrics must be monitored in the computer network during the voice data transmission to ensure proper voice service quality the end-user has paid for, especially in the wireless networks. In addition to the QoS, research area called Quality of Experience (QoE provides metrics and methods for quality evaluation from the end-user’s perspective. This article focuses on a QoE estimation of Voice over IP (VoIP calls in the wireless networks using network simulator. Results contribute to voice quality estimation based on characteristics of the wireless network and location of a wireless client.

  14. Risk measures for power failures in transmission systems

    Science.gov (United States)

    Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye

    2016-11-01

    We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.

  15. Risk measures for power failures in transmission systems.

    Science.gov (United States)

    Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye

    2016-11-01

    We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.

  16. Analysis the Performance of Coded WSK-DWDM Transmission System

    Directory of Open Access Journals (Sweden)

    Bobby Barua

    2012-12-01

    Full Text Available Dense Wavelength Division Multiplexing (DWDM is the system with more than eight active wavelengths per fiber. Again high data rates as well as long spans between amplifiers in a chain require high optical power per channel to satisfy the signal to noise ratio (SNR requirements. So the DWDM systems with long repeater-less spans, the simultaneous requirements of high launched power and low dispersion fibers lead to the generation of new waves by four-wave mixing (FWM, which degrades the performance of a multi-channel transmission system. Several methods have been proposed to mitigate the effect of FWM crosstalk. All these works are performed considering only binary WSK scheme. Although M-ary WSK (M>2 schemes have higher spectral efficiency than binary WSK system. Again, the BER performances for M-ary WDM system are not satisfactory with the effect of FWM. Therefore, in this paper we include the effect of FWM on the performance of an M-ary WDM system and try to mitigate the effect by employing the energy efficient convolution code in a normal dispersive fiber as well as in a dispersion shifted fiber (DSF.

  17. Toroidal Continuously Variable Transmission Systems: Terminology and Present Studies

    Directory of Open Access Journals (Sweden)

    Ahmet YILDIZ

    2014-04-01

    Full Text Available The use of continuously variable transmission systems in many different areas such as aerospace, robotics, machinery and automotive industries as an alternative to conventional speed changers with constant ratio becomes widely.Especially in the automotive industry, these systems have been used increasingly, since they enable that internal combustion engines in vehicles run at optimal speeds, and consequently provide considerable fuel savings and therefore lower emission values and also they provide powerful acceleration and quiet working. CVT systems have several constructive variants such as belted, chained, balled, toroidal etc. In this paper, toroidal CVT systems based on elastohydrodynamic principles are concerned with, and fundamental works of last two decades in this field are reviewed. However, the relevant terminology and dynamics along with the control of these systems are briefly treated for better understanding of the literature mentioned. Attention is drawn to the lack of some significant issues in present research works, and potential future works are pointed out. This paper, to the authors’ knowledge, will be the first review on toroidal CVT systems in Turkish literature

  18. 77 FR 26275 - Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS

    Science.gov (United States)

    2012-05-03

    ... Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS AGENCY...``''sts for long-term transmission service. During the NOS process, utilities and power generators (including wind generators and power marketers) requested the use of BPA's transmission system to...

  19. Transmission of multiple system atrophy prions to transgenic mice.

    Science.gov (United States)

    Watts, Joel C; Giles, Kurt; Oehler, Abby; Middleton, Lefkos; Dexter, David T; Gentleman, Steve M; DeArmond, Stephen J; Prusiner, Stanley B

    2013-11-26

    Prions are proteins that adopt alternative conformations, which become self-propagating. Increasing evidence argues that prions feature in the synucleinopathies that include Parkinson's disease, Lewy body dementia, and multiple system atrophy (MSA). Although TgM83(+/+) mice homozygous for a mutant A53T α-synuclein transgene begin developing CNS dysfunction spontaneously at ∼10 mo of age, uninoculated TgM83(+/-) mice (hemizygous for the transgene) remain healthy. To determine whether MSA brains contain α-synuclein prions, we inoculated the TgM83(+/-) mice with brain homogenates from two pathologically confirmed MSA cases. Inoculated TgM83(+/-) mice developed progressive signs of neurologic disease with an incubation period of ∼100 d, whereas the same mice inoculated with brain homogenates from spontaneously ill TgM83(+/+) mice developed neurologic dysfunction in ∼210 d. Brains of MSA-inoculated mice exhibited prominent astrocytic gliosis and microglial activation as well as widespread deposits of phosphorylated α-synuclein that were proteinase K sensitive, detergent insoluble, and formic acid extractable. Our results provide compelling evidence that α-synuclein aggregates formed in the brains of MSA patients are transmissible and, as such, are prions. The MSA prion represents a unique human pathogen that is lethal upon transmission to Tg mice and as such, is reminiscent of the prion causing kuru, which was transmitted to chimpanzees nearly 5 decades ago.

  20. Hybrid energy harvesting/transmission system for embedded devices

    Science.gov (United States)

    Hehr, Adam; Park, Gyuhae; Farinholt, Kevin

    2012-04-01

    In most energy harvesting applications the need for a reliable long-term energy supply is essential in powering embedded sensing and control electronics. The goal of many harvesters is to extract energy from the ambient environment to power hardware; however in some applications there may be conditions in which the harvester's performance cannot meet all of the demands of the embedded electronics. One method for addressing this shortfall is to supplement harvested power through the transmission of wireless energy, a concept that has successfully been demonstrated by the authors in previous studies. In this paper we present our findings on the use of a single electromagnetic coil to harvest kinetic energy in a solenoid configuration, as well as background and directed wireless energy in the 2.4 GHz radio frequency (RF) bands commonly used in WiFi and cellular phone applications. The motivation for this study is to develop a compact energy harvester / receiver that conserves physical volume, while providing multi-modal energy harvesting capabilities. As with most hybrid systems there are performance trade-offs that must be considered when capturing energy from different physical sources. As part of this paper, many of the issues related to power transmission, physical design, and potential applications are addressed for this device.

  1. Diagnostics of power transmissions system with tooth gear

    Directory of Open Access Journals (Sweden)

    Grzegorz WOJNAR

    2008-01-01

    Full Text Available This paper presents results of laboratory tests that were aimed at detecting early stages of various faults in toothed wheels by measurement and analysis of transverse vibration speed of the transmission gear shafts. In experimental investigation, cracking of the root tooth and chipping of the tooth were detected. The laser vibrometer Ometron VH300+ was used for non-contact measurement of shaft transversal vibration speed. Gear vibrations were recorded in selected points of gear housing and gear shafts at different speeds and gear loads. Results were analyzed and compared but in this paper is presented only selected examples. This paper shows that on the basis of the transverse vibration speed of transmission gear shafts, it is possible to detect defects at an earlier stage than on the basis of the housing vibration accelerations. In the case of measuring gear shaft vibration velocity, the way of the signal generated by the defect of a gear wheel (or bearing is shortened as well as the influence of composed transmittance of the bearing-gear housing system is eliminated. WV time-frequency analysis and complex continuous wavelet transformations were used for detection. The authors introduced a measure of local tooth damage, which was proportional to the size of damage. The results of research presented in this paperconfirmed that the defect's measure is very sensitive to the development of teeth faults.

  2. Efficacy of a New Medical Information system, Ubiquitous Healthcare Service with Voice Inception Technique in Elderly Diabetic Patients.

    Science.gov (United States)

    Kim, Kyoung Min; Park, Kyeong Seon; Lee, Hyun Ju; Lee, Yun Hee; Bae, Ji Seon; Lee, Young Joon; Choi, Sung Hee; Jang, Hak Chul; Lim, Soo

    2015-12-11

    We have demonstrated previously that an individualized health management system using advanced medical information technology, named ubiquitous (u)-healthcare, was helpful in achieving better glycemic control than routine care. Recently, we generated a new u-healthcare system using a voice inception technique for elderly diabetic patients to communicate information about their glucose control, physical activity, and diet more easily. In a randomized clinical trial, 70 diabetic patients aged 60-85 years were assigned randomly to a standard care group or u-healthcare group for 6 months. The primary end points were the changes in glycated hemoglobin (HbA1c) and glucose fluctuation assessed by the mean amplitude glycemic excursion (MAGE). Changes in body weight, lifestyle, and knowledge about diabetes were also investigated. After 6 months, the HbA1c levels decreased significantly in the u-healthcare group (from 8.6 ± 1.0% to 7.5 ± 0.6%) compared with the standard care group (from 8.7 ± 0.9% to 8.2 ± 1.1%, P < 0.01). The MAGE decreased more in the u-healthcare group than in the standard care group. Systolic blood pressure and body weight decreased and liver functions improved in the u-healthcare group, but not in the standard care group. The u-healthcare system with voice inception technique was effective in achieving glycemic control without hypoglycemia in elderly diabetic patients (Clinicaltrials.gov: NCT01891474).

  3. Economically adapted transmission systems in open access schemes -- Application of genetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Rudnick, H.; Palma, R.; Cura, E.; Silva, C. [Pontificia Univ. Catolica de Chile, Santiago (Chile). Dept. de Ingenieria Electrica

    1996-08-01

    A dynamic transmission planning methodology using a genetic algorithm is formulated for the purpose of determining an economically adapted electric transmission system in a deregulated open access environment. Transmission investment sensitivity information linked to short term marginal income is used. A computer program is developed and applied to obtain a long range adapted transmission grid for the Chilean electrical system. Two open access pricing methodologies are evaluated in a spot price framework, as applied to the adapted grid over the time horizon.

  4. Forming the Calculated Dynamic Transmission Systems of Wheeled Vehicles

    Directory of Open Access Journals (Sweden)

    A. B. Fominykh

    2017-01-01

    Full Text Available To calculate dynamic loading of transmission parts of wheeled vehicles, it is necessary to build up the appropriate calculated dynamic systems and determine their inertial, elastic, and damping parameters.The initial point of this process is to form an initial dynamic system. Hereafter, to cut the time of computations there is a need to reduce the number of masses of this system, and sometimes simplify its structure. The main requirement to be fulfilled in this case is that the calculated dynamical system is to be equivalent to the initial one (in terms of similarity of the vibrational process characteristics in these systems, i.e., the frequencies and modes of oscillations of both systems, their amplitude-frequency characteristics. This is possible when the energy characteristics of the corresponding systems are equal, i.e. their kinetic and potential energies, dissipative functions, and external force energies.Usually, when forming the initial and calculated dynamic systems, all types of friction are reduced to a linearly viscous one. However, it disables us to investigate the motion of these systems if there is an arbitrary, in particular, poly-harmonic action (for example, on the side of the internal combustion engine, since in this case the linear friction coefficients given will depend on the frequency and amplitude of the oscillations.The paper is aimed at determining the equivalent parameters of calculated dynamic systems of wheeled vehicles, including the dissipative parameters for the general case of friction.On the basis of energy principles, the expressions are obtained to determine the equivalent inertial, elastic, and damping parameters of the calculated dynamical systems of wheeled vehicles when the structure is changed and the number of masses of the system is decreased. The presented technique enables us to investigate the motion of these systems under arbitrary, including poly-harmonic, action on the system, using the

  5. On multiuser switched diversity transmission for spectrum sharing systems

    KAUST Repository

    Qaraqe, Marwa

    2012-01-01

    In this paper, we develop multiuser access schemes for spectrum sharing systems whereby secondary users share the spectrum with primary users. In particular, we devise two schemes for selecting the user among those that satisfy the interference constraints and achieve an acceptable signal-to-noise ratio (SNR) level. The first scheme selects the user with the maximum SNR at the receiver, whereas in the second scheme the users are scanned in a sequential manner until an acceptable user is found. In addition, we consider two power adaptive settings. In the on/off power adaptive setting, the users transmit based on whether the interference constraint is met or not while in the full power adaptive setting, the users vary their transmission power to satisfy the interference constraint. Finally, we present numerical results of our proposed algorithms where we show the trade-off between the average spectral efficiency and average feedback load of both schemes. © 2012 ICST.

  6. Vibration and noise analysis of a gear transmission system

    Science.gov (United States)

    Choy, F. K.; Qian, W.; Zakrajsek, J. J.; Oswald, F. B.

    1993-01-01

    This paper presents a comprehensive procedure to predict both the vibration and noise generated by a gear transmission system under normal operating conditions. The gearbox vibrations were obtained from both numerical simulation and experimental studies using a gear noise test rig. In addition, the noise generated by the gearbox vibrations was recorded during the experimental testing. A numerical method was used to develop linear relationships between the gearbox vibration and the generated noise. The hypercoherence function is introduced to correlate the nonlinear relationship between the fundamental noise frequency and its harmonics. A numerical procedure was developed using both the linear and nonlinear relationships generated from the experimental data to predict noise resulting from the gearbox vibrations. The application of this methodology is demonstrated by comparing the numerical and experimental results from the gear noise test rig.

  7. Vibration Signature Analysis of a Faulted Gear Transmission System

    Science.gov (United States)

    Choy, F. K.; Huang, S.; Zakrajsek, J. J.; Handschuh, R. F.; Townsend, D. P.

    1996-01-01

    A comprehensive procedure in predicting faults in gear transmission systems under normal operating conditions is presented. Experimental data were obtained from a spiral bevel gear fatigue test rig at NASA/Lewis. Time-synchronous-averaged vibration data were recorded throughout the test as the fault progressed from a small single pit to severe pitting over several teeth, and finally tooth fracture. A numerical procedure based on the Wigner-Ville distribution was used to examine the time-averaged vibration data. Results from the Wigner-Ville procedure are compared to results from a variety of signal analysis techniques that include time-domain analysis methods and frequency analysis methods. Using photographs of the gear tooth at various stages of damage, the limitations and accuracy of the various techniques are compared and discussed. Conclusions are drawn from the comparison of the different approaches as well as the applicability of the Wigner-Ville method in predicting gear faults.

  8. Gas data transmission system by satellite telephone; Systeme de transmission de donnees sur le gaz utilisant le telephone par satellite

    Energy Technology Data Exchange (ETDEWEB)

    Ogasawara, S.; Tanji, A. [Dengineer Co., Ltd (Japan); Akiyama, S. [Buyo Gas Company (Japan)

    2000-07-01

    Dengineer Co., Ltd. and Buyo Gas Co., Ltd. had been developing and using the data and alarm transmission system by public telephone since 1984, that was first practical use in Japan. It is very important for business management that adjusts the production value of gas by measuring gas pressures in each governor. Also, it is indispensable to know the accident of gas leakage or abnormal gas pressure quickly. But this convenient system is not spread yet in Japanese market cause of the following reasons. - Take time and cost for installation of terminal station. - Terminal station is apt to damage by thunder. - Big disaster must stop working this system. In order to solve those problems, we have developed and tested the system organized of the satellite telephone system and solar cells for power. This system will be very useful for wide place, not only Japanese market but also the area, which has no electricity and phone. Also, it will be convenient for international rescue as is able to access it from the foreign countries. (authors)

  9. Transmission imaging for integrated PET-MR systems.

    Science.gov (United States)

    Bowen, Spencer L; Fuin, Niccolò; Levine, Michael A; Catana, Ciprian

    2016-08-07

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method's performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with (18)F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm(-1) was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly

  10. Transmission imaging for integrated PET-MR systems

    Science.gov (United States)

    Bowen, Spencer L.; Fuin, Niccolò; Levine, Michael A.; Catana, Ciprian

    2016-08-01

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method’s performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with 18F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm-1 was recorded for an experimental uniform cylinder phantom scan, while a bias of  translation of the patient table to perform complete tomographic sampling, generated highly quantitative measured μ-maps and is expected to produce images with

  11. Band gap transmission in periodic bistable mechanical systems

    Science.gov (United States)

    Frazier, Michael J.; Kochmann, Dennis M.

    2017-02-01

    We theoretically and numerically investigate the supratransmission phenomenon in discrete, nonlinear systems containing bistable elements. While linear waves cannot propagate within the band gaps of periodic structures, supratransmission allows large-amplitude waves to transmit energy through the band gap. For systems lacking bistability, the threshold amplitude for such energy transmission at a given frequency in the linear band gap is fixed. We show that the topological transitions due to bistability provide an avenue for switching the threshold amplitude between two well-separated values. Moreover, this versatility is achieved while leaving the linear dispersion properties of the system essentially unchanged. Interestingly, the behavior changes when an elastic chain is coupled to bistable resonators (in an extension of the well-studied linear locally resonant metamaterials). Here, we show that a fraction of the injected energy is confined near the boundary due to the resonators, providing a means of regulating the otherwise unrestrained energy flow due to supratransmission. Together, the results illustrate new means of controlling nonlinear wave propagation and energy transport in systems having multi-stable elements.

  12. Self-powered system with wireless data transmission.

    Science.gov (United States)

    Hu, Youfan; Zhang, Yan; Xu, Chen; Lin, Long; Snyder, Robert L; Wang, Zhong Lin

    2011-06-08

    We demonstrate the first self-powered system driven by a nanogenerator (NG) that works wirelessly and independently for long-distance data transmission. The NG was made of a free cantilever beam that consisted of a five-layer structure: a flexible polymer substrate, ZnO nanowire textured films on its top and bottom surfaces, and electrodes on the surfaces. When it was strained to 0.12% at a strain rate of 3.56% S(-1), the measured output voltage reached 10 V, and the output current exceeded 0.6 μA (corresponding power density 10 mW/cm(3)). A system was built up by integrating a NG, rectification circuit, capacitor for energy storage, sensor, and RF data transmitter. Wireless signals sent out by the system were detected by a commercial radio at a distance of 5-10 m. This study proves the feasibility of using ZnO nanowire NGs for building self-powered systems, and its potential application in wireless biosensing, environmental/infrastructure monitoring, sensor networks, personal electronics, and even national security.

  13. Keyboard With Voice Output

    Science.gov (United States)

    Huber, W. C.

    1986-01-01

    Voice synthesizer tells what key is about to be depressed. Verbal feedback useful for blind operators or where dim light prevents sighted operator from seeing keyboard. Also used where operator is busy observing other things while keying data into control system. Used as training aid for touch typing, and to train blind operators to use both standard and braille keyboards. Concept adapted to such equipment as typewriters, computers, calculators, telephones, cash registers, and on/off controls.

  14. Asymmetric operation of AC power transmission systems : the key to optimizing power system reliability and economics

    Energy Technology Data Exchange (ETDEWEB)

    Marceau, R.J. [University of Ontario Inst. of Technology, Oshawa, ON (Canada); McGillis, D.T. [McGill Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering]|[Concordia Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering; Sana, A.R.

    2006-07-01

    This book provides an invaluable tool for professionals working in the field of electrical engineering and applied science. It presents a simple and cost-effective strategy to operate alternating current (AC) power transmission systems more reliably and economically. Typically, bulk power transmission systems are operated symmetrically. When a problem such as a short-circuit occurs on a 3-phase line on an individual phase, all 3 phases are taken out of service. Such a strategy is fundamentally inefficient, given that most faults are single-line-to-ground faults. The more effective operating strategy presented in this book is based on the concept of asymmetric operation, which defines the operation of a 3-phase AC transmission line as 3 independently operated entities. As such, a 3-phase line can be operated with 1 or 2 phases out of service for single-line transmission corridors or with 1 , 2 or 3 phases out of service in the case of multiple-line corridors. This approach also maintains 3-phase symmetrical operation at its extremities, thereby protecting loads and power plants from undesirable voltages and currents. The overall integrity of 3-phase transmission is maintained in terms of power delivery, balanced voltages and currents even in the event of failures in part of the transmission system. The result is improved security. 67 refs., 42 tabs., 73 figs., 2 appendices.

  15. Houston, We Have A Problem: A History of Air-to-Ground Voice Transmissions from the U.S. Manned Space Program

    Science.gov (United States)

    Swanson, Glen E.

    2002-01-01

    America's manned civil space program unfolded before the public through a vast array of sights and sounds. Beginning with Alan Shepard's first flight into space and continuing through the early Space Shuttle Program, nearly every word spoken between Earth and astronaut was recorded, transcribed and published for the world to see. Engineers installed onboard tape recorders which, as part of their data-saving function, recorded astronaut intercom communications. Some of these recordings were made during critical phases of each flight when the preservation of all data was essential. These tapes along with hundreds of others that gathered on the ground from each mission became the focused attention of legions of typists whose single job was converting voice to paper. Armed with reel-to-reel tape players, electric typewriters and reams of paper, these folks hammered out thousands of pages of transcripts. The results are a permanent written record that reveal a different side to America's manned space program; one in which its astronauts are both professional and profane, calm and excited, confident and unsure, healthy and sick - in a word, "human."

  16. The Diagnostic System of A – 604 Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Czaban Jaroslaw

    2014-09-01

    Full Text Available Automatic gearbox gains increasing popularity in Europe. Little interest in diagnosis of such type of transmission in Poland results from the fact of small share in the whole market of operated cars, so there is a lack of availability of special diagnostic devices. These factors cause issues of expensive repairs, often involving a replacement of subassembly to new or aftermarket one. To a small extent some prophylactic diagnostic tests are conducted, which can eliminate future gearbox system failures. In the paper, the proposition of diagnostic system of popular A - 604 gearbox was presented. The authors are seeking for the possibility of using such type of devices to functional elaboration of gearboxes after renovation. The built system pursues the drive of the researched object, connected with simulated load, where special controller, replacing the original one, is responsible for controlling gearbox operation. This way is used to evaluate the mechanic and hydraulic parts' state. Analysis of signal runs, registered during measurements lets conclude about operation correctness, where as comparison with stock data verifies the technical state of an automatic gearbox.

  17. Psychometric assessments of life quality and voice for teachers within the municipal system, in Bauru, SP, Brazil

    Directory of Open Access Journals (Sweden)

    Janaína Gheissa Martinello

    2011-12-01

    Full Text Available Studies show a high prevalence of vocal alterations among teachers. One of the criteria for the establishment of the prevalence of vocal alteration is based on teachers' self-perception. Objective: This study aimed at comparing voice-disordered quality of life measures between a group of teachers who reported vocal alteration and a group of teachers who did not, by verifying the teachers' perception regarding the impact of vocal alteration in the different dimensions of voice quality of life. Material and Methods: Ninety-seven (97 teachers answered three psychometric protocols of voice quality of life: Voice Handicap Index (VHI, Voice-Related Quality of Life (V-RQOL, and the Voice Activity Participation Profile (VAPP, in addition to a questionnaire for characterization of the sample. Results: The results were that 39.8% of the teachers reported vocal alteration. When comparing voice measures between the groups (with and without vocal alteration, statistically significant differences were observed: the total score of VHI, total score of V-RQOL and total score of VAAP and its dimensions. It was also verified that the physical dimension of VHI has a greater impact among the dimensions of this protocol. For VRQOL, the most striking dimension was the physical functioning domain, both indicating the laryngeal discomfort and the impact of voice on communication, in teachers with and without complaints. As for VAAP, no domain prevailed over the others in the group with no complaints. For teachers with complaints, three domains, i.e., daily communication, work, and emotions have a greater impact than social communication. The limitation and restriction scores were calculated as well, and it was observed the limitation of activities is greater than the restriction of activities, both in the group with and the group without complaints. Conclusion: One may conclude that the teachers who reported vocal alterations better realize the impact of voice in

  18. A meta-analysis of in-vehicle and nomadic voice-recognition system interaction and driving performance.

    Science.gov (United States)

    Simmons, Sarah M; Caird, Jeff K; Steel, Piers

    2017-09-01

    Driver distraction is a growing and pervasive issue that requires multiple solutions. Voice-recognition (V-R) systems may decrease the visual-manual (V-M) demands of a wide range of in-vehicle system and smartphone interactions. However, the degree that V-R systems integrated into vehicles or available in mobile phone applications affect driver distraction is incompletely understood. A comprehensive meta-analysis of experimental studies was conducted to address this knowledge gap. To meet study inclusion criteria, drivers had to interact with a V-R system while driving and doing everyday V-R tasks such as dialing, initiating a call, texting, emailing, destination entry or music selection. Coded dependent variables included detection, reaction time, lateral position, speed and headway. Comparisons of V-R systems with baseline driving and/or a V-M condition were also coded. Of 817 identified citations, 43 studies involving 2000 drivers and 183 effect sizes (r) were analyzed in the meta-analysis. Compared to baseline, driving while interacting with a V-R system is associated with increases in reaction time and lane positioning, and decreases in detection. When V-M systems were compared to V-R systems, drivers had slightly better performance with the latter system on reaction time, lane positioning and headway. Although V-R systems have some driving performance advantages over V-M systems, they have a distraction cost relative to driving without any system at all. The pattern of results indicates that V-R systems impose moderate distraction costs on driving. In addition, drivers minimally engage in compensatory performance adjustments such as reducing speed and increasing headway while using V-R systems. Implications of the results for theory, design guidelines and future research are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Transmissibility of the monkeypox virus clades via respiratory transmission: investigation using the prairie dog-monkeypox virus challenge system.

    Directory of Open Access Journals (Sweden)

    Christina L Hutson

    Full Text Available Monkeypox virus (MPXV is endemic within Africa where it sporadically is reported to cause outbreaks of human disease. In 2003, an outbreak of human MPXV occurred in the US after the importation of infected African rodents. Since the eradication of smallpox (caused by an orthopoxvirus (OPXV related to MPXV and cessation of routine smallpox vaccination (with the live OPXV vaccinia, there is an increasing population of people susceptible to OPXV diseases. Previous studies have shown that the prairie dog MPXV model is a functional animal model for the study of systemic human OPXV illness. Studies with this model have demonstrated that infected animals are able to transmit the virus to naive animals through multiple routes of exposure causing subsequent infection, but were not able to prove that infected animals could transmit the virus exclusively via the respiratory route. Herein we used the model system to evaluate the hypothesis that the Congo Basin clade of MPXV is more easily transmitted, via respiratory route, than the West African clade. Using a small number of test animals, we show that transmission of viruses from each of the MPXV clade was minimal via respiratory transmission. However, transmissibility of the Congo Basin clade was slightly greater than West African MXPV clade (16.7% and 0% respectively. Based on these findings, respiratory transmission appears to be less efficient than those of previous studies assessing contact as a mechanism of transmission within the prairie dog MPXV animal model.

  20. Multipath/RFI/modulation study for DRSS-RFI problem: Voice coding and intelligibility testing for a satellite-based air traffic control system

    Science.gov (United States)

    Birch, J. N.; Getzin, N.

    1971-01-01

    Analog and digital voice coding techniques for application to an L-band satellite-basedair traffic control (ATC) system for over ocean deployment are examined. In addition to performance, the techniques are compared on the basis of cost, size, weight, power consumption, availability, reliability, and multiplexing features. Candidate systems are chosen on the bases of minimum required RF bandwidth and received carrier-to-noise density ratios. A detailed survey of automated and nonautomated intelligibility testing methods and devices is presented and comparisons given. Subjective evaluation of speech system by preference tests is considered. Conclusion and recommendations are developed regarding the selection of the voice system. Likewise, conclusions and recommendations are developed for the appropriate use of intelligibility tests, speech quality measurements, and preference tests with the framework of the proposed ATC system.

  1. Delay related issues in integrated voice and data networks

    Science.gov (United States)

    Gruber, J. G.

    1981-06-01

    The described investigation is concerned with the problem of transmitting voice with data in a computer communications network. The motivations for considering mixed voice and data traffic in such a shared network environment include the advent of new voice related applications with the technology now existing to economically support them, and the desire to plan for and design future integrated networks for reasons of economy and flexibility. Attention is given to the problem of variable delays in a shared network environment handling voice traffic. Previous work in packetized voice, as well as various approaches to integrated voice and data transmission, are reviewed. These approaches may be regarded as enhanced versions of circuit, packet, and hybrid switching. The impact of network interfacing and delay considerations for voice traffic is discussed.

  2. 基于ADPCM的数字语音存储与回放系统%Digital voice storage and replay system based on ADPCM

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    With singlechip and FPGA as the cybernetics core,the system realizes voice storage and reply system. It can collect and simulate voice signals and stereo signals from earphone and lift utilization rate of memory by the use of ADPCM, which means the voice can be stored for more than 2 minutes. Based on the short⁃time Fourier transform principle,it can also achieve spectral analysis of voice signals and real⁃time display. Through using the stereo audio amplifier,each sound track can be adjusted and muted. Furthermore,some measures as pre⁃emphasis,de⁃emphasis and anti⁃aliasing filtering are used in this system to increase SNR efficiently and get good quality of the recorded voice for a longer time.%  系统以单片机和FPGA为控制核心,实现了语音存储与回放系统。能够采集模拟语音信号以及耳机立体声信号,以ADPCM(自适应差分编码)的方式提高了存储器的利用率,语音存储时间可达2 min;基于短时傅里叶变换原理,实现了语音信号的频谱分析与实时显示。同时,利用立体声音频功放播放语音,每声道音量可调并具有静噪功能。此外,系统还采用预加重、去加重、抗混叠滤波等措施,有效地提高了信噪比。语音回放质量良好,存储时间较长。

  3. Using the Voice to Design Ceramics

    DEFF Research Database (Denmark)

    Hansen, Flemming Tvede; Jensen, Kristoffer

    2011-01-01

    SoundShaping, a system to create ceramics from the human voice. Based on a generic audio feature extraction system, and the principal component analysis to ensure that the pertinent information in the voice is used, a 3D shape is created using simple geometric rules. This shape is output to a 3D printer...

  4. Using the Voice to Design Ceramics

    DEFF Research Database (Denmark)

    Hansen, Flemming Tvede; Jensen, Kristoffer

    2011-01-01

    SoundShaping, a system to create ceramics from the human voice. Based on a generic audio feature extraction system, and the principal component analysis to ensure that the pertinent information in the voice is used, a 3D shape is created using simple geometric rules. This shape is output to a 3D printer...

  5. Speaking and Nonspeaking Voice Professionals: Who Has the Better Voice?

    Science.gov (United States)

    Chitguppi, Chandala; Raj, Anoop; Meher, Ravi; Rathore, P K

    2017-04-18

    Voice professionals can be classified into two major subgroups: the primarily speaking and the primarily nonspeaking voice professionals. Nonspeaking voice professionals mainly include singers, whereas speaking voice professionals include the rest of the voice professionals. Although both of these groups have high vocal demands, it is currently unknown whether both groups show similar voice changes after their daily voice use. Comparison of these two subgroups of voice professionals has never been done before. This study aimed to compare the speaking voice of speaking and nonspeaking voice professionals with no obvious vocal fold pathology or voice-related complaints on the day of assessment. After obtaining relevant voice-related history, voice analysis and videostroboscopy were performed in 50 speaking and 50 nonspeaking voice professionals. Speaking voice professionals showed significantly higher incidence of voice-related complaints as compared with nonspeaking voice professionals. Voice analysis revealed that most acoustic parameters including fundamental frequency, jitter percent, and harmonic-to-noise ratio were significantly higher in speaking voice professionals, whereas videostroboscopy did not show any significant difference between the two groups. This is the first study of its kind to analyze the effect of daily voice use in the two subgroups of voice professionals with no obvious vocal fold pathology. We conclude that voice professionals should not be considered as a homogeneous group. The detrimental effects of excessive voice use were observed to occur more significantly in speaking voice professionals than in nonspeaking voice professionals. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  6. CCNA Voice Study Guide, Exam 640-460

    CERN Document Server

    Froehlich, Andrew

    2010-01-01

    The ultimate guide to the new CCNA voice network administrator certification exam. The new CCNA Voice exam tests candidates on their ability to implement a Cisco VoIP solution. Network administrators of voice systems will appreciate that the CCNA Voice Study Guide focuses completely on the information required by the exam. Along with hands-on labs and an objective map showing where each objective is covered, this guide includes a CD with the Sybex Test Engine, flashcards, and entire book in PDF format.: The new CCNA Voice certification will be valuable for administrators of voice network syste

  7. Response prediction techniques and case studies of a path blocking system based on Global Transmissibility Direct Transmissibility method

    Science.gov (United States)

    Wang, Zengwei; Zhu, Ping; Zhao, Jianxuan

    2017-02-01

    In this paper, the prediction capabilities of the Global Transmissibility Direct Transmissibility (GTDT) method are further developed. Two path blocking techniques solely using the easily measured variables of the original system to predict the response of a path blocking system are generalized to finite element models of continuous systems. The proposed techniques are derived theoretically in a general form for the scenarios of setting the response of a subsystem to zero and of removing the link between two directly connected subsystems. The objective of this paper is to verify the reliability of the proposed techniques by finite element simulations. Two typical cases, the structural vibration transmission case and the structure-borne sound case, in two different configurations are employed to illustrate the validity of proposed techniques. The points of attention for each case have been discussed, and conclusions are given. It is shown that for the two cases of blocking a subsystem the proposed techniques are able to predict the new response using measured variables of the original system, even though operational forces are unknown. For the structural vibration transmission case of removing a connector between two components, the proposed techniques are available only when the rotational component responses of the connector are very small. The proposed techniques offer relative path measures and provide an alternative way to deal with NVH problems. The work in this paper provides guidance and reference for the engineering application of the GTDT prediction techniques.

  8. Unified active and reactive power modulation of HVDC transmission systems

    Science.gov (United States)

    Grund, C. E.; Pohl, R. V.

    1981-11-01

    The power modulation of a high voltage direct current (HVDC) system for stabilization of an ac/dc network was investigated. It was found that simultaneous modulation of both dc current and voltage was more effective than just current modulation by itself, since the dc voltage modulation could be used to minimize the reactive power changes resulting from a change of the dc current. This helps stabilize the ac busbar voltages at the converters, which reduces undesirable load flow changes to voltage dependent ac loads, thus improving the effectiveness of the dc power modulation. This unified modulation control concept was evaluated by means of digital computer studies as well as a special purpose HVDC simulator. Several combined ac/dc power transmission systems were synthesized for testing of different modulation controller concepts. An optimum controller design incorporating a linear quadratic control algorithm with full state feedback was first studied. This provided a basis for comparison of suboptimal controller designs utilizing reduced state feedback and a Kalman filter state reconstruction technique.

  9. Study on New Concatenated Code in WDM Optical Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    YUAN Jian-guo; JIANG Ze; MAO You-ju; YE Wen-wei

    2007-01-01

    A new concatenated code of RS(255,239)+BCH(2 040,1 930) code to be suitable for WDM optical transmission systems is proposed.The simulation results show that this new concatenated code,compared with the RS(255,239)+CSOC(k0/n0=6/7,J=8) code in ITU-T G.75.1,has a lower redundancy and better error-correction performance,furthermore,its net coding gain(NCG) is respectively 0.46 dB,0.43 dB more than that of RS(255,239)+CSOC(k0/n0 =6/7,J=8) code and BCH(3 860,3 824)+BCH(2 040,1 930) code in ITU-T G.75.1 at the third iteration for the bit error rate(BER) of 10-12.Therefore,the new super forward error correction(Super-FEC) concatenated code can be better used in ultra long-haul,ultra large-capacity and ultra high-speed WDM optical communication systems.

  10. Statistics and Analysis on Reliability of HVDC Transmission Systems of SGCC

    Institute of Scientific and Technical Information of China (English)

    Xu

    2010-01-01

    Reliability level of HVDC power transmission systems becomes an important factor impacting the entire power grid. The author analyzes the reliability of HVDC power transmission systems owned by SGCC since 2003 in respect of forced outage times, forced energy unavailability, scheduled energy unavailability and energy utilization efficiency. The results show that the reliability level of HVDC power transmission systems owned by SGCC is improving. By analyzing different reliability indices of HVDC power transmission system, the maximum asset benefits of power grid can be achieved through building a scientific and reasonable reliability evaluation system.

  11. Leveraging voice

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth

    2017-01-01

    researchers improve our practices and how could digital online video help offer more positive stories about research and higher education? How can academics in higher education be better to tell about our research, thereby reclaiming and leveraging our voice in a post-factual era? As higher education......This paper speculates on how researchers share research without diluting our credibility and how to make strategies for the future. It also calls for consideration of new traditions and practices for communicating knowledge to a wider audience across multiple media platforms. How might we...... continues to engage with digital and networked technologies it becomes increasingly relevant to question why and how academics could (re) position research knowledge in the digital and online media landscape of today and the future. The paper highlights methodological issues that arise in relation...

  12. Feeling voices.

    Directory of Open Access Journals (Sweden)

    Paolo Ammirante

    Full Text Available Two experiments investigated deaf individuals' ability to discriminate between same-sex talkers based on vibrotactile stimulation alone. Nineteen participants made same/different judgments on pairs of utterances presented to the lower back through voice coils embedded in a conforming chair. Discrimination of stimuli matched for F0, duration, and perceived magnitude was successful for pairs of spoken sentences in Experiment 1 (median percent correct = 83% and pairs of vowel utterances in Experiment 2 (median percent correct = 75%. Greater difference in spectral tilt between "different" pairs strongly predicted their discriminability in both experiments. The current findings support the hypothesis that discrimination of complex vibrotactile stimuli involves the cortical integration of spectral information filtered through frequency-tuned skin receptors.

  13. 基于高速公路网的无线语音系统的设计%Design of wireless voice system for highway network

    Institute of Scientific and Technical Information of China (English)

    康维新; 缪晶

    2014-01-01

    为了便于对公路的维护与保养,需要一款具有通信功能的移动设备,提出了基于高速公路网的对讲终端的解决方案,在服务端采用嵌入式LINUX平台,利用ALSA数字音频接口,结合麦克风采集原始PCM音频数据,采用G726标准进行音频编解码,采用RTP/RTCP协议,基于wifi实现音频的网络传输。在用户端用支持LINUX系统的PC对音频数据进行编解码,播放。该方案的终端基于高速公路现有网络,具有移动性,经济性,且语音清晰,实时性好。%In order to maintain and repair the road, a kind of mobile devices with communi-cation function is necessary.The solution which is based on the highway network intercom terminal was proposed.Used the embedded LINUX platform on the service side, ALSA digit-al audio interface, standard G726 to realize audio codec and used RTP /RTCP protocol based on wifi to realize network transmission of audio.In the client-to-use, the PC which can support LINUX system was used to code and decode the audio and play it.The terminal of the solution was based on the existing highway network and it has the advantages of mobili-ty, economy, clear voice and real time.

  14. 47 CFR 73.644 - Subscription TV transmission systems.

    Science.gov (United States)

    2010-10-01

    ... adjacent channel stations must not increase over that resulting from the transmission of programming with..., of Subpart H of Part 15 of the FCC Rules for TV Interface Devices. (c) Prior to commencing the transmission of encoded subscription programming, the licensee or permittee of a TV broadcast or low power...

  15. Power Improvement of Transmission Line Using High Voltage Direct Current (Hvdc Transmission System

    Directory of Open Access Journals (Sweden)

    Lasisi, H

    2016-08-01

    Full Text Available The use of long EHV (Extremely High Voltage ac lines for the transmission of electrical energy increases the line reactance and susceptance which limits the thermal loadings on the line in order to keep sufficient margin against transient instability. With the scheme proposed in this paper, it is possible to load the lines very close to their limit with zero reactance and susceptance. The conductors are allowed to carry usual ac along with dc superimposed on it. The added dc power flow does not cause any transient instability. The scheme comprises a twelve-pulse bridge rectifier, dc-links, pulse width modulated (PSW-voltage sourced inverter (VSI and converter transformers. The master current controller is used to implement the scheme which senses ac current and regulates the dc current orders for converters online such that conductor current never exceeds its thermal limit. This paper gives the feasibility of converting a double circuit ac line into composite ac–dc power transmission line given the advantage of stability improvement, damping oscillations, voltage stabilization and reactive power compensation for ac weak buses. Simulation and experimental studies using MATLAB (Matrix Laboratory are carried out for the coordinated control as well as independent control of ac and dc power transmissions.

  16. Voith power transmission systems in diesel multiple units and railcars. A review on recent developments

    Energy Technology Data Exchange (ETDEWEB)

    Paetzold, W. [Voith Turbo GmbH und Co. KG, Heidenheim (Germany). Rail Div.

    1999-04-01

    Voith today offers complete transmission systems consisting of hydrodynamic and hydromechanical transmissions with integrated retarders, cardan shafts, final drives and cooling units. For DMUs with underfloor powerpacks, the hydrodynamic power transmission system currently is the pre-eminent drive system worldwide and meets the established standards for rail service, i.e. high availability, low operating costs and a reasonable purchasing price. In this article, the author describes Voith`s contribution to the further development of these transmission systems in several modern dieselhydraulic railcars and DMUs for regional and main-line operations. (orig.)

  17. A Hybrid LCC-VSC HVDC Transmission System Supplying a Passive Load

    Science.gov (United States)

    Kotb, Omar

    High Voltage Direct Current (HVDC) transmission systems continue to be an excellent asset in modern power systems, mainly for their ability to overcome the problems of AC transmission, such as the interconnection of asynchronous grids, stability of long transmission lines, and use of long cables for power transmission. In the past 20 years, Voltage Source Converter (VSC)-HVDC transmission systems were developed and installed in many projects, thereby adding more operational benefits to DC transmission option, such as high controllability, ability to supply weak networks, and reduced converter reactive power demand. Nevertheless, VSC-HVDC transmission suffers from the disadvantages of high losses and cost. In this research, a hybrid HVDC employing a Line Commutated Converter (LCC) as rectifier and a VSC as inverter is used to supply a passive network through a DC cable. The hybrid system is best suited for unidirectional power transmission scenarios, such as power transmission to islands and remote load centers, where the construction of new transmission lines is prohibitively expensive. Control modes for the rectifier and inverter are selected and implemented using Proportional Integral (PI) controllers. Special control schemes are developed for abnormal operating conditions such as starting at light load and recovering from AC network faults. The system performance under steady state and transient conditions is investigated by EMTP-RV simulations. The results show the feasibility of the hybrid system.

  18. Stress transmission through a model system of cohesionless elastic grains

    Science.gov (United States)

    Da Silva, Miguel; Rajchenbach, Jean

    2000-08-01

    Understanding the mechanical properties of granular materials is important for applications in civil and chemical engineering, geophysical sciences and the food industry, as well as for the control or prevention of avalanches and landslides. Unlike continuous media, granular materials lack cohesion, and cannot resist tensile stresses. Current descriptions of the mechanical properties of collections of cohesionless grains have relied either on elasto-plastic models classically used in civil engineering, or on a recent model involving hyperbolic equations. The former models suggest that collections of elastic grains submitted to a compressive load will behave elastically. Here we present the results of an experiment on a two-dimensional model system-made of discrete square cells submitted to a point load-in which the region in which the stress is confined is photoelastically visualized as a parabola. These results, which can be interpreted within a statistical framework, demonstrate that the collective response of the pile contradicts the standard elastic predictions and supports a diffusive description of stress transmission. We expect that these findings will be applicable to problems in soil mechanics, such as the behaviour of cohesionless soils or sand piles.

  19. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  20. Smart Grid Wide-Area Transmission System Visualization

    Directory of Open Access Journals (Sweden)

    Thomas J. Overbye

    2015-12-01

    Full Text Available The installation of vast quantities of additional new sensing and communication equipment, in conjunction with building the computing infrastructure to store and manage data gathered by this equipment, has been the first step in the creation of what is generically referred to as the “smart grid” for the electric transmission system. With this enormous capital investment in equipment having been made, attention is now focused on developing methods to analyze and visualize this large data set. The most direct use of this large set of new data will be in data visualization. This paper presents a survey of some visualization techniques that have been deployed by the electric power industry for visualizing data over the past several years. These techniques include pie charts, animation, contouring, time-varying graphs, geographic-based displays, image blending, and data aggregation techniques. The paper then emphasizes a newer concept of using word-sized graphics called sparklines as an extremely effective method of showing large amounts of time-varying data.

  1. 47 CFR 73.6024 - Transmission standards and system requirements.

    Science.gov (United States)

    2010-10-01

    ... RADIO SERVICES RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6024 Transmission... cause any condition of uncorrectable interference due to radiation of radio frequency energy outside...

  2. Study for wireless power transmission of nuclear robot system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jongseog [Central Research Institute of Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2013-05-15

    Gasoline engine or electric motor is generally used for driving power of working. Gasoline tank is uncomfortable to carry. Battery capacity does not sustain long time working. Frequent moving back of robot to power charger or refueling tank is inconvenient. Long power cable connection occur winding problem if there are complex structures in walking way. We need some solution for continuous supply of robot energy at the free moving condition of robot. 'Wireless power transmission' is one of the solutions. Some experiment result to transmit wireless power to moving robot is described herein. To find possible wireless power transmission method for nuclear robot, wireless power transmission tests were performed. As result of these tests, it was confirmed that wireless power transmission by using dipole and mat type magnetic induction were possible. As result of flying robot experiment, it was realized that development of light weight core for receiver and wave reflection device for high directional transmitter are necessary for practical use of the dipole type wireless power transmission. Small size core and high directional transmitter will be next target. Mat type wireless power transmission is regarded as useful for robot power charging station in the inside containment.

  3. Settlement Between Electric Transmission Companies under the Point of Connection Tariff or "Postal Stamp" System (Japanese)

    OpenAIRE

    Hatta, Tatsuo

    2009-01-01

    This paper discusses how an electric transmission company in a pass-through area should settle the cost of a pass-through with the neighboring transmission companies under the point-of-connection tariff system. First, the paper shows that if the cost of the pass-through is settled based on the principle that determines the (metered) power transmission fares for ordinary customers (i.e. injectors and withdrawers) of the transmission companies, the fare receipts of the pass-through transmission...

  4. Wavelet Based Fault Detection, Classification in Transmission System with TCSC Controllers

    Directory of Open Access Journals (Sweden)

    G.Satyanarayana,

    2015-08-01

    Full Text Available This paper presents simulation results of the application of distance relays for the protection of transmission systems employing flexible alternating current transmission controllers such as Thyristor Controlled Series Capacitor (TCSC. The complete digital simulation of TCSC within a transmission system is performed in the MATLAB/Simulink environment using the Power System Block set (PSB. This paper presents an efficient method based on wavelet transforms both fault detection and classification which is almost independent of fault impedance, fault location and fault inception angle of transmission line fault currents with FACTS controllers.

  5. Simulation Study on Coil Design of Wireless Power Transfer System for Optimal Transmission Efficiency

    Directory of Open Access Journals (Sweden)

    Hao Qiang

    2013-05-01

    Full Text Available As an emerging research field, Wireless Power Transfer (WPT has attracted wide spread attention recently. In this study, the coil design of WPT system for optimal transmission efficiency is investigated. We deduce Tthe design criteria are deduced to meet various conditions of transmission distance and load. The results of simulation and experiment show the transmission efficiency from transmitting coil to receiving coil can keep high when the corresponding optimal condition is achieved. Thusen it can improve the overall transmission efficiency of the WPT system and it makes it suitable for the practical application of WPT system.

  6. Automatic Speech Recognition Systems for the Evaluation of Voice and Speech Disorders in Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Andreas Maier

    2010-01-01

    Full Text Available In patients suffering from head and neck cancer, speech intelligibility is often restricted. For assessment and outcome measurements, automatic speech recognition systems have previously been shown to be appropriate for objective and quick evaluation of intelligibility. In this study we investigate the applicability of the method to speech disorders caused by head and neck cancer. Intelligibility was quantified by speech recognition on recordings of a standard text read by 41 German laryngectomized patients with cancer of the larynx or hypopharynx and 49 German patients who had suffered from oral cancer. The speech recognition provides the percentage of correctly recognized words of a sequence, that is, the word recognition rate. Automatic evaluation was compared to perceptual ratings by a panel of experts and to an age-matched control group. Both patient groups showed significantly lower word recognition rates than the control group. Automatic speech recognition yielded word recognition rates which complied with experts' evaluation of intelligibility on a significant level. Automatic speech recognition serves as a good means with low effort to objectify and quantify the most important aspect of pathologic speech—the intelligibility. The system was successfully applied to voice and speech disorders.

  7. Voice communications over packet radio networks

    Science.gov (United States)

    Seah, M. M.

    1985-03-01

    The use of packet virtual circuit technique for voice communications in military radio networks was investigated. The work was concerned with various aspects of networking which include network modeling, communications techniques, traffic analysis and network control. An attempt has been made to develop a simple yet efficient time slot assignment algorithm . This was analyzed under a variety of slot depths and networks topologies using computer simulation. The Erlang' B results were used to provide more insight into the channel characteristics of the packet radio networks. The capabilities of implementing TDMA/CDMA hybrid schemes in the system were scrutinized. A method to estimate the transmission capacity of the inter-node links was found. We demonstrate its effectiveness in controlling local congestion by computer simulation. Graphical results were presented to highlight the behavior of the proposed packet radio networks. We concluded that an appropriate link weight function would provide efficient and reliable network services.

  8. 47 CFR 74.795 - Digital low power TV and TV translator transmission system facilities.

    Science.gov (United States)

    2010-10-01

    ... translator transmission system facilities. (a) A digital low power TV or TV translator station shall operate... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator transmission system facilities. 74.795 Section 74.795 Telecommunication FEDERAL COMMUNICATIONS...

  9. Experimental characterization of dispersion maps with Raman gain in 160 Gb/s transmission systems

    DEFF Research Database (Denmark)

    Zhenbo, Xu; Seoane, Jorge; Siahlo, Andrei;

    2004-01-01

    We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance.......We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance....

  10. Dimensionality in voice quality.

    Science.gov (United States)

    Bele, Irene Velsvik

    2007-05-01

    This study concerns speaking voice quality in a group of male teachers (n = 35) and male actors (n = 36), as the purpose was to investigate normal and supranormal voices. The goal was the development of a method of valid perceptual evaluation for normal to supranormal and resonant voices. The voices (text reading at two loudness levels) had been evaluated by 10 listeners, for 15 vocal characteristics using VA scales. In this investigation, the results of an exploratory factor analysis of the vocal characteristics used in this method are presented, reflecting four dimensions of major importance for normal and supranormal voices. Special emphasis is placed on the effects on voice quality of a change in the loudness variable, as two loudness levels are studied. Furthermore, the vocal characteristics Sonority and Ringing voice quality are paid special attention, as the essence of the term "resonant voice" was a basic issue throughout a doctoral dissertation where this study was included.

  11. Voice box (image)

    Science.gov (United States)

    The larynx, or voice box, is located in the neck and performs several important functions in the body. The larynx is involved in swallowing, breathing, and voice production. Sound is produced when the air which ...

  12. Voice and Aging

    Science.gov (United States)

    ... dramatic voice changes are those during childhood and adolescence. The larynx (or voice box) and vocal cord tissues do not fully mature until late teenage years. Hormone-related changes during adolescence are ...

  13. Performance analysis for optimum transmission and comparison with maximal ratio transmission for MIMO systems with cochannel interference

    Directory of Open Access Journals (Sweden)

    Lin Sheng-Chou

    2011-01-01

    Full Text Available Abstract This article presents the performance analysis of multiple-input/multiple-output (MIMO systems with quadrature amplitude modulation (QAM transmission in the presence of cochannel interference (CCI in nonfading and flat Rayleigh fading environments. The use of optimum transmission (OT and maximum ratio transmission (MRT is considered and compared. In addition to determining precise results for the performance of QAM in the presence of CCI, it is our another aim in this article to examine the validity of the Gaussian interference model in the MRT-based systems. Nyquist pulse shaping and the effects of cross-channel intersymbol interference produced by CCI due to random symbol of the interfering signals are considered in the precise interference model. The error probability for each fading channel is estimated fast and accurately using Gauss quadrature rules which can approximate the probability density function (pdf of the output residual interference. The results of this article indicate that Gaussian interference model may overestimate the effects of interference, particularly, for high-order MRT-based MIMO systems over fading channels. In addition, OT cannot always outperform MRT due to the significant noise enhancement when OT intends to cancel CCI, depending on the combination of the antennas at the transmitter and the receiver, number of interference and the statistical characteristics of the channel.

  14. Shifting voices with participant roles: Voice qualities and speech registers in Mesoamerica

    OpenAIRE

    Sicoli, M.

    2010-01-01

    Although an increasing number of sociolinguistic researchers consider functions of voice qualities as stylistic features, few studies consider cases where voice qualities serve as the primary signs of speech registers. This article addresses this gap through the presentation of a case study of Lachixio Zapotec speech registers indexed though falsetto, breathy, creaky, modal, and whispered voice qualities. I describe the system of contrastive speech registers in Lachixio Zapotec and then track...

  15. Preliminary survey of integrated monitoring system for transmission liens. Sodensen sogo kanshi system no yobi kento

    Energy Technology Data Exchange (ETDEWEB)

    Sasano, Takao; Nishiyama, Fumihiko

    1988-04-01

    The integrated monitoring system of transmission lines utilizing ground wire with built-in optical fibres(OPGW) which was put to practical use was surveyed. The overhead transmission lines have potential to be impeded supply owing to the line exposure to severe natural envioronment or by the change of surrounding environment such as trees, buildings under lines and ground or by deterioration of equipments. This report describes the system to monitor integrally the transmission lines by using OPGW or sensor technology to maintain and operate with higher reliability and lower cost and to reflect in the design, except the conventional maintenance and checking. The effect to foresee and prevent accidents is expected from this system, but the regional difference must be considered. This system can provide continously reliable monitoring, collection of maintenance informations and operation support and further can provide accident informations to be used in the design through the evaluation. It is necessary to use highly reliable repeaters for optical informations, protect instruments under intense field, prevent malfunction and develop the auto-movable robot for taking picture and local weather prediction system in order to realize this system. (5 figs, 6 tabs, 8 refs)

  16. A Unique Wavelet Steganography Based Voice Biometric Protection Scheme

    Directory of Open Access Journals (Sweden)

    Sanjaypande M. B

    2013-03-01

    Full Text Available Voice biometric is an easy and cost effective biometric technique which requires minimalistic hardware and software complexity. General voice biometric needs a voice phrase by user which is processed with Mel Filter and Vector Quantized features are extracted. Vector quantization reduces the codebook size but decreases the accuracy of recognition. Therefore we propose a voice biometric system where voice file's non quantized code books are matched with spoken phrase. In order to ensure security to such direct voice sample we embed the voice file in a randomly selected image using DWT technique. Imposters are exposed to only images and are unaware of the voice files. We show that the technique produces better efficiency in comparison to VQ based technique.

  17. Design and Realization of Phased Array Radar Optical Fiber Transmission System

    Institute of Scientific and Technical Information of China (English)

    HU Shan-qing; LIU Feng; LONG Teng

    2007-01-01

    One optical fiber transmission system is designed.The modularization optical fiber transmission adapters were utilized in the system,so the system structure could be flexibly scalable.The sub-array adapter and signal processor adapter were designed and realized utilizing the new field programmable gate array (FPGA) which could drive the optical transceiver.The transmission agreement was designed based on the data stream.In order to solve the signal synchronization problem of the optical fiber transmitted phased array radar,a method named synchronous clock was designed.The fiber transmission error code rate of the system was zero with an experimental transmission velocity of 800 Mbit/s.The phased array radar system has detected the airplane target,thus validated the feasibility of the design method.

  18. Parameter design and performance analysis of zero inertia continuously variable transmission system

    Institute of Scientific and Technical Information of China (English)

    胡建军; 吉毅; 晏玖江

    2015-01-01

    In order to solve the problem of weak power performance of vehicle equipped with continuously variable transmission (CVT) system working under transient operating conditions, a new CVT equipped with planetary gear mechanism and flywheel was researched, a design method of transmission parameter optimization was proposed, and the comprehensive matching control strategy was established for the new transmission system. Fuzzy controllers for throttle opening and CVT speed ratio were designed, and power performance and fuel economy of both vehicles respectively equipped with conventional CVT system and new transmission system wrere compared and analyzed by simulation. The results show that power performance and fuel economy of the vehicle equipped with new transmission system are better than that equipped with conventional CVT, thus the rationality of the parameter design method and control algorithm are verified.

  19. Voice and endocrinology

    OpenAIRE

    KVS Hari Kumar; Anurag Garg; Ajai Chandra, N. S.; Singh, S. P.; Rakesh Datta

    2016-01-01

    Voice is one of the advanced features of natural evolution that differentiates human beings from other primates. The human voice is capable of conveying the thoughts into spoken words along with a subtle emotion to the tone. This extraordinary character of the voice in expressing multiple emotions is the gift of God to the human beings and helps in effective interpersonal communication. Voice generation involves close interaction between cerebral signals and the peripheral apparatus consistin...

  20. PROXY-BASED PATCHING STREAM TRANSMISSION STRATEGY IN MOBILE STREAMING MEDIA SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Liao Jianxin; Lei Zhengxiong; Ma Xutao; Zhu Xiaomin

    2006-01-01

    A mobile transmission strategy, PMPatching (Proxy-based Mobile Patching) transmission strategy is proposed, it applies to the proxy-based mobile streaming media system in Wideband Code Division Multiple Access (WCDMA) network. Performance of the whole system can be improved by using patching stream to transmit anterior part of the suffix that had been played back, and by batching all the demands for the suffix arrived in prefix period and patching stream transmission threshold period. Experimental results show that this strategy can efficiently reduce average network transmission cost and number of channels consumed in central streaming media server.

  1. Virtual Pipeline System Testbed to Optimize the U.S. Natural Gas Transmission Pipeline System

    Energy Technology Data Exchange (ETDEWEB)

    Kirby S. Chapman; Prakash Krishniswami; Virg Wallentine; Mohammed Abbaspour; Revathi Ranganathan; Ravi Addanki; Jeet Sengupta; Liubo Chen

    2005-06-01

    The goal of this project is to develop a Virtual Pipeline System Testbed (VPST) for natural gas transmission. This study uses a fully implicit finite difference method to analyze transient, nonisothermal compressible gas flow through a gas pipeline system. The inertia term of the momentum equation is included in the analysis. The testbed simulate compressor stations, the pipe that connects these compressor stations, the supply sources, and the end-user demand markets. The compressor station is described by identifying the make, model, and number of engines, gas turbines, and compressors. System operators and engineers can analyze the impact of system changes on the dynamic deliverability of gas and on the environment.

  2. Writing with Voice

    Science.gov (United States)

    Kesler, Ted

    2012-01-01

    In this Teaching Tips article, the author argues for a dialogic conception of voice, based in the work of Mikhail Bakhtin. He demonstrates a dialogic view of voice in action, using two writing examples about the same topic from his daughter, a fifth-grade student. He then provides five practical tips for teaching a dialogic conception of voice in…

  3. Tips for Healthy Voices

    Science.gov (United States)

    ... social interaction as well as for most people’s occupation. Proper care and use of your voice will give you the best chance for having a healthy voice for your entire lifetime. Hoarseness or roughness in your voice is often ...

  4. Voice over IP Security

    CERN Document Server

    Keromytis, Angelos D

    2011-01-01

    Voice over IP (VoIP) and Internet Multimedia Subsystem technologies (IMS) are rapidly being adopted by consumers, enterprises, governments and militaries. These technologies offer higher flexibility and more features than traditional telephony (PSTN) infrastructures, as well as the potential for lower cost through equipment consolidation and, for the consumer market, new business models. However, VoIP systems also represent a higher complexity in terms of architecture, protocols and implementation, with a corresponding increase in the potential for misuse. In this book, the authors examine the

  5. Non-systemic transmission of tick-borne diseases: A network approach

    Science.gov (United States)

    Ferreri, Luca; Bajardi, Paolo; Giacobini, Mario

    2016-10-01

    Tick-borne diseases can be transmitted via non-systemic (NS) transmission. This occurs when tick gets the infection by co-feeding with infected ticks on the same host resulting in a direct pathogen transmission between the vectors, without infecting the host. This transmission is peculiar, as it does not require any systemic infection of the host. The NS transmission is the main efficient transmission for the persistence of the tick-borne encephalitis virus in nature. By describing the heterogeneous ticks aggregation on hosts through a bipartite graphs representation, we are able to mathematically define the NS transmission and to depict the epidemiological conditions for the pathogen persistence. Despite the fact that the underlying network is largely fragmented, analytical and computational results show that the larger is the variability of the aggregation, and the easier is for the pathogen to persist in the population.

  6. Condition Assessment Technologies for Water Transmission and Distribution Systems

    Science.gov (United States)

    As part of the U.S. Environmental Protection Agency’s (EPA’s) Aging Water Infrastructure Research Program, this research was conducted to identify and characterize the state of the technology for structural condition assessment of drinking water transmission and distribution syst...

  7. Condition Assessment of Drinking Water Transmission and Distribution Systems

    Science.gov (United States)

    Condition assessment of water transmission and distribution mains is the collection of data and information through direct and/or indirect methods, followed by analysis of the data and information, to make a determination of the current and/or future structural, water quality, an...

  8. 47 CFR 73.875 - Modification of transmission systems.

    Science.gov (United States)

    2010-10-01

    ... RADIO BROADCAST SERVICES Low Power FM Broadcast Stations (LPFM) § 73.875 Modification of transmission... application on FCC Form 318. (1) Any construction of a new tower structure for broadcast purposes, except for replacement of an existing tower with a new tower of identical height and geographic coordinates. (2)...

  9. Initial assessment: electromagnetic compatibility aspects of proposed SPS Microwave Power Transmission System (MPTS) operations

    Energy Technology Data Exchange (ETDEWEB)

    1978-02-01

    An analysis of major concerns with regard to the effects on radio and electronic systems by the proposed Microwave Power Transmission System for transmitting power from a satellite solar power station to earth is presented. (LCL)

  10. The Usefulness and Feasibility of Mobile Interface in Tuberculosis Notification (MITUN) Voice Based System for Notification of Tuberculosis by Private Medical Practitioners – A Pilot Project

    Science.gov (United States)

    Velayutham, Banurekha; Thomas, Beena; Nair, Dina; Thiruvengadam, Kannan; Prashant, Suma; Kittusami, Sathyapriya; Vijayakumar, Harivanzan; Chidambaram, Meenachi; Shivakumar, Shri Vijay Bala Yogendra; Jayabal, Lavanya; Jhunjhunwala, Ashok; Swaminathan, Soumya

    2015-01-01

    Introduction Tuberculosis (TB) is a notifiable disease and health care providers are required to notify every TB case to local authorities. We conducted a pilot study to determine the usefulness and feasibility of mobile interface in TB notification (MITUN) voice based system for notification of TB cases by private medical practitioners. Methodology The study was conducted during September 2013 to October 2014 in three zones of Chennai, an urban setting in South India. Private clinics wherein services are provided by single private medical practitioners were approached. The steps involved in MITUN included: Registration of the practitioners and notification of TB cases by them through voice interactions. Pre and post-intervention questionnaires were administered to collect information on TB notification practices and feasibility of MITUN after an implementation period of 6 months. Results A total of 266 private medical practitioners were approached for the study. Of them, 184 (69%) participated in the study; of whom 11 (6%) practitioners used MITUN for TB notification. Reasons for not using MITUN include lack of time, referral of patients to government facility, issues related to patient confidentiality and technical problems. Suggestions for making mobile phone based TB notification process user-friendly included reducing call duration, including only crucial questions and using missed call or SMS options. Conclusion The performance (feasibility and usefulness) of MITUN voice based system for TB notification in the present format was sub-optimal. Perceived problems, logistical and practical issues preclude scale–up of notification of TB by private practitioners. PMID:26376197

  11. The Usefulness and Feasibility of Mobile Interface in Tuberculosis Notification (MITUN Voice Based System for Notification of Tuberculosis by Private Medical Practitioners--A Pilot Project.

    Directory of Open Access Journals (Sweden)

    Banurekha Velayutham

    Full Text Available Tuberculosis (TB is a notifiable disease and health care providers are required to notify every TB case to local authorities. We conducted a pilot study to determine the usefulness and feasibility of mobile interface in TB notification (MITUN voice based system for notification of TB cases by private medical practitioners.The study was conducted during September 2013 to October 2014 in three zones of Chennai, an urban setting in South India. Private clinics wherein services are provided by single private medical practitioners were approached. The steps involved in MITUN included: Registration of the practitioners and notification of TB cases by them through voice interactions. Pre and post-intervention questionnaires were administered to collect information on TB notification practices and feasibility of MITUN after an implementation period of 6 months.A total of 266 private medical practitioners were approached for the study. Of them, 184 (69% participated in the study; of whom 11 (6% practitioners used MITUN for TB notification. Reasons for not using MITUN include lack of time, referral of patients to government facility, issues related to patient confidentiality and technical problems. Suggestions for making mobile phone based TB notification process user-friendly included reducing call duration, including only crucial questions and using missed call or SMS options.The performance (feasibility and usefulness of MITUN voice based system for TB notification in the present format was sub-optimal. Perceived problems, logistical and practical issues preclude scale-up of notification of TB by private practitioners.

  12. Scientific Bases of Human-Machine Communication by Voice

    Science.gov (United States)

    Schafer, Ronald W.

    1995-10-01

    The scientific bases for human-machine communication by voice are in the fields of psychology, linguistics, acoustics, signal processing, computer science, and integrated circuit technology. The purpose of this paper is to highlight the basic scientific and technological issues in human-machine communication by voice and to point out areas of future research opportunity. The discussion is organized around the following major issues in implementing human-machine voice communication systems: (i) hardware/software implementation of the system, (ii) speech synthesis for voice output, (iii) speech recognition and understanding for voice input, and (iv) usability factors related to how humans interact with machines.

  13. Analysis of transmission efficiency of the superconducting resonance coil according the materials of cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Kyeong; Hwang, Jun Won; Choi, Hyo Sang [Chosun University, Gwangju (Korea, Republic of)

    2016-03-15

    The wireless power transfer (WPT) system using a magnetic resonance was based on magnetic resonance coupling of the transmission and the receiver coils. In these system, it is important to maintain a high quality-factor (Q-factor) to increase the transmission efficiency of WPT system. Our research team used a superconducting coil to increase the Q-factor of the magnetic resonance coil in WPT system. When the superconductor is applied in these system, we confirmed that transmission efficiency of WPT system was higher than normal conductor coil through a preceding study. The efficiency of the transmission and the receiver coil is affected by the magnetic shielding effect of materials around the coils. The magnetic shielding effect is dependent on the type, thickness, frequency, distance, shape of materials. Therefore, it is necessary to study the WPT system on the basis of these conditions. In this paper, the magnetic shield properties of the cooling system were analyzed using the High-Frequency Structure Simulation (HFSS, Ansys) program. We have used the shielding materials such as plastic, aluminum and iron, etc. As a result, when we applied the fiber reinforced polymer (FRP), the transmission efficiency of WPT was not affected because electromagnetic waves went through the FRP. On the other hand, in case of a iron and aluminum, transmission efficiency was decreased because of their electromagnetic shielding effect. Based on these results, the research to improve the transmission efficiency and reliability of WPT system is continuously necessary.

  14. Seismic Performance Research of Transmission Tower in Consideration of the Pile-soil-structure System

    Science.gov (United States)

    Liu, Chuncheng; Mao, Long; Wang, Chongyang; Zha, Chuanming

    2016-11-01

    The seismic performance of transmission tower in consideration of pile-soil- structure dynamic interaction is researched through numerical simulation. Based on a transmission tower of a specific project, pile-soil-transmission tower coupled system is established. By using the method of time history, the pile-soil- transmission tower system dynamic response under seismic load were calculated, and comparing with the results without considering interaction system. Results show that, after considering interaction of the system, the period of the structure have extended and the mode of the structure lagged. On soft sites, compare with no considering the interaction, the results have a big difference, the relative increment of the maximum displacement at the top of the tower is 39.82%, respectively. Therefore it is suggested that the pile-soil-structure dynamic interaction should be fully considered in aseismic design of transmission tower on soft sites and medium soft sites.

  15. A Sandbox Development For Demonstrating Bom Transmission In A Plm And Erp Integrated System

    OpenAIRE

    Zeng, Zhen

    2014-01-01

    Integrating Product Lifecycle Management (PLM) and Enterprise Resource Planning (ERP) in a company is important. Currently, many companies have difficulties on integrating PLM and ERP systems. This study developed a prototype (sandbox) of PLM and ERP integrated system for demonstrating BOM transmission in a PLM and ERP integrated system, describing key aspects of system integration and BOM transmission. This sandbox will facilitate users' knowledge on how to process transactions in a PLM and ...

  16. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  17. Community voices: barriers and opportunities for programmes to successfully prevent vertical transmission of HIV identified through consultations among people living with HIV

    Directory of Open Access Journals (Sweden)

    Christoforos Mallouris

    2012-07-01

    Full Text Available Introduction: In 2010, two global networks of people living with HIV, the International Community of Women Living with HIV (ICW Global and the Global Network of People living with HIV (GNP +  were invited to review a draft strategic framework for the global scale up of prevention of vertical transmission (PVT through the primary prevention of HIV and the prevention of unintended pregnancies among women living with HIV. In order to ensure recommendations were based on expressed needs of people living with HIV, GNP+ and ICW Global undertook a consultation amongst people living with HIV which highlighted both facilitators and barriers to prevention services. This commentary summarizes the results of that consultation. Discussion: The consultation was comprised of an online consultation (moderated chat-forum with 36 participants from 16 countries, an anonymous online e-survey (601 respondents from 58 countries, and focus-group discussions with people living with HIV in Jamaica (27 participants. The consultation highlighted the discrepancies across regions with respect to access to essential packages of PVT services. However, the consultation participants also identified common barriers to access, including a lack of trustworthy sources of information, service providers’ attitudes, and gender-based violence. In addition, participant responses revealed common facilitators of access, including quality counselling on reproductive choices, male involvement, and decentralized services. Conclusions: The consultation provided some understanding and insight into the participants’ experiences with and recommendations for PVT strategies. Participants agreed that successful, comprehensive PVT programming require greater efforts to both prevent primary HIV infection among young women and girls and, in particular, targeted efforts to ensure that women living with HIV and their partners are supported to avoid unintended pregnancies and to have safe, healthy

  18. Transmission needs across a fully renewable European power system

    CERN Document Server

    Rodriguez, Rolando A; Andresen, Gorm B; Heide, Dominik; Greiner, Martin

    2013-01-01

    The residual load and excess power generation of 27 European countries with a 100% penetration of variable renewable energy sources are explored in order to quantify the benefit of power transmission between countries. Estimates are based on extensive weather data, which allows for modelling of hourly mismatches between the demand and renewable generation from wind and solar photovoltaics. For separated countries, balancing is required to cover around 24% of the total annual energy consumption. This number can be reduced down to 15% once all countries are networked together with uncon- strained interconnectors. The reduction represents the maximum possible benefit of transmission for the countries. The total Net Transfer Capacity of the unconstrained interconnectors is roughly twelve times larger than current values. However, constrained interconnector capacities six times larger than the current values are found to provide 97% of the maximum possible benefit of cooperation. This motivates a detailed investig...

  19. Optical signal monitoring in phase modulated optical fiber transmission systems

    Science.gov (United States)

    Zhao, Jian

    Optical performance monitoring (OPM) is one of the essential functions for future high speed optical networks. Among the parameters to be monitored, chromatic dispersion (CD) is especially important since it has a significant impact on overall system performance. In this thesis effective CD monitoring approaches for phase-shift keying (PSK) based optical transmission systems are investigated. A number of monitoring schemes based on radio frequency (RF) spectrum analysis and delay-tap sampling are proposed and their performance evaluated. A method for dispersion monitoring of differential phase-shift keying (DPSK) signals based on RF power detection is studied. The RF power spectrum is found to increase with the increase of CD and decrease with polarization mode dispersion (PMD). The spectral power density dependence on CD is studied theoretically and then verified through simulations and experiments. The monitoring sensitivity for nonreturn-to-zero differential phase-shift keying (NRZ-DPSK) and return-to-zero differential phase-shift keying (RZ-DPSK) based systems can reach 80ps/nm/dB and 34ps/nm/dB respectively. The scheme enables the monitoring of differential group delay (DGD) and CD simultaneously. The monitoring sensitivity of CD and DGD can reach 56.7ps/nm/dB and 3.1ps/dB using a bandpass filter. The effects of optical signal-to-noise ratio (OSNR), DGD, fiber nonlinearity and chirp on the monitoring results are investigated. Two RF pilot tones are employed for CD monitoring of DPSK signals. Specially selected pilot tone frequencies enable good monitoring sensitivity with minimum influence on the received signals. The dynamic range exceeding 35dB and monitoring sensitivity up to 9.5ps/nm/dB are achieved. Asynchronous sampling technique is employed for CD monitoring. A signed CD monitoring method for 10Gb/s NRZ-DPSK and RZ-DPSK systems using asynchronous delay-tap sampling technique is studied. The demodulated signals suffer asymmetric waveform distortion if

  20. HIV transmission in a state prison system, 1988-2005.

    Directory of Open Access Journals (Sweden)

    Krishna Jafa

    Full Text Available INTRODUCTION: HIV prevalence among state prison inmates in the United States is more than five times higher than among nonincarcerated persons, but HIV transmission within U.S. prisons is sparsely documented. We investigated 88 HIV seroconversions reported from 1988-2005 among male Georgia prison inmates. METHODS: We analyzed medical and administrative data to describe seroconverters' HIV testing histories and performed a case-crossover analysis of their risks before and after HIV diagnosis. We sequenced the gag, env, and pol genes of seroconverters' HIV strains to identify genetically-related HIV transmission clusters and antiretroviral resistance. We combined risk, genetic, and administrative data to describe prison HIV transmission networks. RESULTS: Forty-one (47% seroconverters were diagnosed with HIV from July 2003-June 2005 when voluntary annual testing was offered. Seroconverters were less likely to report sex (OR [odds ratio] = 0.02, 95% CI [confidence interval]: 0-0.10 and tattooing (OR = 0.03, 95% CI: <0.01-0.20 in prison after their HIV diagnosis than before. Of 67 seroconverters' specimens tested, 33 (49% fell into one of 10 genetically-related clusters; of these, 25 (76% reported sex in prison before their HIV diagnosis. The HIV strains of 8 (61% of 13 antiretroviral-naïve and 21 (40% of 52 antiretroviral-treated seroconverters were antiretroviral-resistant. DISCUSSION: Half of all HIV seroconversions were identified when routine voluntary testing was offered, and seroconverters reduced their risks following their diagnosis. Most genetically-related seroconverters reported sex in prison, suggesting HIV transmission through sexual networks. Resistance testing before initiating antiretroviral therapy is important for newly-diagnosed inmates.

  1. Voice handicap in singers.

    Science.gov (United States)

    Murry, Thomas; Zschommler, Anne; Prokop, Jan

    2009-05-01

    The study aimed to determine the differences in responses to the Voice Handicap Index (VHI-10) between singers and nonsingers and to evaluate the ranked order differences of the VHI-10 statements for both groups. The VHI-10 was modified to include statements related to the singing voice for comparison to the original VHI-10. Thirty-five nonsingers with documented voice disorders responded to the VHI-10. A second group, consisting of 35 singers with voice complaints, responded to the VHI-10 with three statements added specifically addressing the singing voice. Data from both groups were analyzed in terms of overall subject self-rating of voice handicap and the rank order of statements from least to most important. The difference between the mean VHI-10 for the singers and nonsingers was not statistically significant, thus, supporting the validity of the VHI-10. However, the 10 statements were ranked differently in terms of their importance by both groups. In addition, when three statements related specifically to the singing voice were substituted in the original VHI-10, the singers judged their voice problem to be more severe than when using the original VHI-10. The type of statements used to assess self-perception of voice handicap may be related to the subject population. Singers with voice problems do not rate their voices to be more handicapped than nonsingers unless statements related specifically to singing are included.

  2. Linearization Technologies for Broadband Radio-Over-Fiber Transmission Systems

    Directory of Open Access Journals (Sweden)

    Xiupu Zhang

    2014-11-01

    Full Text Available Linearization technologies that can be used for linearizing RoF transmission are reviewed. Three main linearization methods, i.e. electrical analog linearization, optical linearization, and electrical digital linearization are presented and compared. Analog linearization can be achieved using analog predistortion circuits, and can be used for suppression of odd order nonlinear distortion components, such as third and fifth order. Optical linearization includes mixed-polarization, dual-wavelength, optical channelization and the others, implemented in optical domain, to suppress both even and odd order nonlinear distortion components, such as second and third order. Digital predistortion has been a widely used linearization method for RF power amplifiers. However, digital linearization that requires analog to digital converter is severely limited to hundreds of MHz bandwidth. Instead, analog and optical linearization provide broadband linearization with up to tens of GHz. Therefore, for broadband radio over fiber transmission that can be used for future broadband cloud radio access networks, analog and optical linearization are more appropriate than digital linearization. Generally speaking, both analog and optical linearization are able to improve spur-free dynamic range greater than 10 dB over tens of GHz. In order for current digital linearization to be used for broadband radio over fiber transmission, the reduced linearization complexity and increased linearization bandwidth are required. Moreover, some digital linearization methods in which the complexity can be reduced, such as Hammerstein type, may be more promising and require further investigation.

  3. Dynamic Efficiency of a Container Crane’s Hoisting Transmission System under Hoisting Dynamic Load

    Directory of Open Access Journals (Sweden)

    Yuanyuan Liu

    2016-01-01

    Full Text Available The dynamic efficiency of hoisting transmission system on a container crane is fundamental for accurate efficiency prediction, while the dynamic efficiency of hoisting transmission system has not been investigated sufficiently. This paper will focus on dynamic efficiency of hoisting transmission system under hoisting dynamic load. A power loss model of gearbox was built. Then the dynamic model of gear transmission was developed including time-varying mesh stiffness and hoisting dynamic load was studied. Power loss, dynamic efficiency, and equivalent static efficiency were conducted in hoisting and lowering working conditions. The result shows that dynamic efficiency which consists of the significant lower frequency component coincided with hoisting load torque of the higher frequency component which is directly related to dynamic mesh and bearing force. And in two processes, the equivalent static efficiency in constant speed stage is min, whereas maximum value occurs in different stage. The research results lay a foundation for hoisting gear transmission dynamic efficiency analysis.

  4. Maryland Public School Standards for Telecommunications Distribution Systems: Infrastructure Design for Voice, Video, and Data Communications.

    Science.gov (United States)

    Maryland State Dept. of Education, Baltimore. School Facilities Branch.

    Telecommunications infrastructure has the dual challenges of maintaining quality while accommodating change, issues that have long been met through a series of implementation standards. This document is designed to ensure that telecommunications systems within the Maryland public school system are also capable of meeting both challenges and…

  5. Design and Implementation of Monophones and Triphones-Based Speech Recognition Systems for Voice Activated Telephony

    Directory of Open Access Journals (Sweden)

    Rupayan Das

    2013-07-01

    Full Text Available Speech recognition is the ability of a machine or program to convert spoken words into its equivalent text form. Nowadays, most recognition systems use Hidden Markov Models for modeling the spoken utterances. In this paper we have implemented two speaker independent speech recognition systems which include all the words required for dialing a phone. The systems contain 42 words including digits from zero to nine and also include names of 20 persons. A total of 16,800 utterances have been used for training each system. The two systems are able to recognize continuous speech and it is implemented with the help of monophones and triphones using HTK. Experimental results show an accuracy of 74.11% for monophones based models and 93.77% for triphones based models.

  6. State of the art analysis of online fault location on AC cables in underground transmission systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Gudmundsdottir, Unnur Stella; Bak, Claus Leth

    2011-01-01

    In this article the state of the art research for online fault location on cross-bonded transmission level cables is presented. The article is focused on the difficulties in using the algorithms developed for OHL-systems and distribution cables directly on cross-bonded transmission cables. Impeda...

  7. The integration of renewable energy sources into electric power transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, P.R.; Dykas, W.P.; Kirby, B.J.; Purucker, S.L. [Oak Ridge National Lab., TN (United States); Lawler, J.S. [Univ. of Tennessee, Knoxville, TN (United States)

    1995-07-01

    Renewable energy technologies such as photovoltaics, solar thermal power plants, and wind turbines are nonconventional, environmentally attractive sources of energy that can be considered for electric power generation. Many of the areas with abundant renewable energy resources (very sunny or windy areas) are far removed from major load centers. Although electrical power can be transmitted over long distances of many hundreds of miles through high-voltage transmission lines, power transmission systems often operate near their limits with little excess capacity for new generation sources. This study assesses the available capacity of transmission systems in designated abundant renewable energy resource regions and identifies the requirements for high-capacity plant integration in selected cases. In general, about 50 MW of power from renewable sources can be integrated into existing transmission systems to supply local loads without transmission upgrades beyond the construction of a substation to connect to the grid. Except in the Southwest, significant investment to strengthen transmission systems will be required to support the development of high-capacity renewable sources of 1000 MW or greater in areas remote from major load centers. Cost estimates for new transmission facilities to integrate and dispatch some of these high-capacity renewable sources ranged from several million dollars to approximately one billion dollars, with the latter figure an increase in total investment of 35%, assuming that the renewable source is the only user of the transmission facility.

  8. Communication protocol in chassis detecting wireless transmission system based on WiFi

    Science.gov (United States)

    In chassis detecting wireless transmission system, the wireless network communication protocol plays a key role in the information exchange and synchronization between the host and chassis PDA. This paper presents a wireless network transmission protocol based on TCP/IP which makes the rules of info...

  9. Joint impact of quantization and clipping on single- and multi-carrier block transmission systems

    NARCIS (Netherlands)

    Yang, H.; Schenk, T.C.W.; Smulders, P.F.M.; Fledderus, E.R.

    2008-01-01

    This work investigates the joint impact of quantization and clipping, caused by analog-to-digital converters (ADCs) with low bit resolutions, on single- and multi-carrier block transmission systems in wireless multipath environments. We consider single carrier block transmission with frequency domai

  10. Mobile Agents: A Distributed Voice-Commanded Sensory and Robotic System for Surface EVA Assistance

    Science.gov (United States)

    Clancey, William J.; Sierhuis, Maarten; Alena, Rick; Crawford, Sekou; Dowding, John; Graham, Jeff; Kaskiris, Charis; Tyree, Kim S.; vanHoof, Ronnie

    2003-01-01

    A model-based, distributed architecture integrates diverse components in a system designed for lunar and planetary surface operations: spacesuit biosensors, cameras, GPS, and a robotic assistant. The system transmits data and assists communication between the extra-vehicular activity (EVA) astronauts, the crew in a local habitat, and a remote mission support team. Software processes ("agents"), implemented in a system called Brahms, run on multiple, mobile platforms, including the spacesuit backpacks, all-terrain vehicles, and robot. These "mobile agents" interpret and transform available data to help people and robotic systems coordinate their actions to make operations more safe and efficient. Different types of agents relate platforms to each other ("proxy agents"), devices to software ("comm agents"), and people to the system ("personal agents"). A state-of-the-art spoken dialogue interface enables people to communicate with their personal agents, supporting a speech-driven navigation and scheduling tool, field observation record, and rover command system. An important aspect of the engineering methodology involves first simulating the entire hardware and software system in Brahms, and then configuring the agents into a runtime system. Design of mobile agent functionality has been based on ethnographic observation of scientists working in Mars analog settings in the High Canadian Arctic on Devon Island and the southeast Utah desert. The Mobile Agents system is developed iteratively in the context of use, with people doing authentic work. This paper provides a brief introduction to the architecture and emphasizes the method of empirical requirements analysis, through which observation, modeling, design, and testing are integrated in simulated EVA operations.

  11. The Bellevue Classification System: nursing's voice upon the library shelves*†

    Science.gov (United States)

    Mages, Keith C

    2011-01-01

    This article examines the inspiration, construction, and meaning of the Bellevue Classification System (BCS), created during the 1930s for use in the Bellevue School of Nursing Library. Nursing instructor Ann Doyle, with assistance from librarian Mary Casamajor, designed the BCS after consulting with library leaders and examining leading contemporary classification systems, including the Dewey Decimal Classification and Library of Congress, Ballard, and National Health Library classification systems. A close textual reading of the classes, subclasses, and subdivisions of these classification systems against those of the resulting BCS, reveals Doyle's belief that the BCS was created not only to organize the literature, but also to promote the burgeoning intellectualism and professionalism of early twentieth-century American nursing. PMID:21243054

  12. Noise and signal interference in optical fiber transmission systems an optimum design approach

    CERN Document Server

    Bottacchi, Stefano

    2008-01-01

    A comprehensive reference to noise and signal interference in optical fiber communications Noise and Signal Interference in Optical Fiber Transmission Systems is a compendium on specific topics within optical fiber transmission and the optimization process of the system design. It offers comprehensive treatment of noise and intersymbol interference (ISI) components affecting optical fiber communications systems, containing coverage on noise from the light source, the fiber and the receiver. The ISI is modeled with a statistical approach, leading to new useful computational m

  13. Wideband Analog Transmission System Based on the External Intensity Electro-Optic Modulator

    Directory of Open Access Journals (Sweden)

    Jiri Svarny

    2016-01-01

    Full Text Available The work deals with design and integration of an analog electro-optic transmission system suitable for some specialized tasks of diagnostics and measurements. The system is based on principle of external intensity modulation of fiber guided laser radiation. Besides wideband and almost lossless transmission the system tolerates extreme length of the transmitting medium and ensures ultimate galvanic barrier between the input and output.

  14. Design of wireless video transmission system based on STM32 microcontroller

    Science.gov (United States)

    Yang, Fan; Ma, Chunting; Li, Haoyi

    2017-03-01

    The design of a wireless video transmission system based on STM32, the system uses the STM32F103VET6 microprocessor as the core, through the video acquisition module collects video data, video data will be sent to the receiver through the wireless transmitting module, receiving data will be displayed on the LCD screen. The software design process of receiver and transmitter is introduced. The experiment proves that the system realizes wireless video transmission function.

  15. Analytical method for coupled transmission error of helical gear system with machining errors, assembly errors and tooth modifications

    Science.gov (United States)

    Lin, Tengjiao; He, Zeyin

    2017-07-01

    We present a method for analyzing the transmission error of helical gear system with errors. First a finite element method is used for modeling gear transmission system with machining errors, assembly errors, modifications and the static transmission error is obtained. Then the bending-torsional-axial coupling dynamic model of the transmission system based on the lumped mass method is established and the dynamic transmission error of gear transmission system is calculated, which provides error excitation data for the analysis and control of vibration and noise of gear system.

  16. Analysis of Bifurcation and Nonlinear Control for Chaos in Gear Transmission System

    Directory of Open Access Journals (Sweden)

    Wang Jingyue

    2013-07-01

    Full Text Available In order to study the bifurcation characteristics and control chaotic vibration of the gear transmission system. The complex dynamics characters of gear transmission system are studied. The dynamical equation and the state equation of gear transmission system are established according to Newton's rule. The route to chaos of the system is studied by the bifurcation diagram, phase portrait, time course diagram and Poincaré map. A method of controlling chaos by nonlinear feedback controller is developed to guide chaotic motions towards regular motions. Numerical simulation shows that with the increase of meshing stiffness, gear transmission system will be from the periodic motion to chaotic motion by doubling bifurcation, the effectiveness and feasibility of the strategy to get rid of chaos by stabilizing the related unstable periodic orbit.

  17. Research and Development of Engine-Generator Set Control System for Tracked Vehicle Electric Transmission System

    Institute of Scientific and Technical Information of China (English)

    HUANG Ying; HUANG Qian; SUN Feng-chun; LIU Bo-lan; LIU Jia

    2007-01-01

    As an energy generating equipment, the engine-generator set supplies power to the electric transmission. Therefore, its control is one of the key technologies of electric vehicles. Based on the discussion about the demands to the engine-generator set in tracked vehicles, the detailed function of engine-generator and the control strategy are determined. The hardware and software of the control system are also developed and tested in a prototype vehicle. The experiment results show that the control system has good reliability and can satisfy the power requirements of vehicles under all operating conditions.

  18. Control system of the physical simulation for the HVDC transmission system

    Science.gov (United States)

    Liu, Zheng; Huang, Tongyuan; Liu, Wei; Ai, Bing; Mou, Daohuai

    2007-12-01

    The intention of this paper is to present the control system of the physical simulation for the Three Gorges HVDC transmission system. It covers all essential control functions which are involved in the continuously working power flow control and power modulation including converter firing and pole current control. This system include two convert stations, They design the fault arbitrator for the dual-controller system based on fault-tolerant technology and figure-safety-comparing technology. The arbitrator can endure long working time with high reliability. Controller A and B not only works independent, but also can controlled by the master controller from CAN bus. At the same time, because the master controller is a industrial PC, we can easy adjust and enhance the functions. This characteristic is especially fit the physical simulation system.

  19. Evaluation of power system security and development of transmission pricing method

    Science.gov (United States)

    Kim, Hyungchul

    The electric power utility industry is presently undergoing a change towards the deregulated environment. This has resulted in unbundling of generation, transmission and distribution services. The introduction of competition into unbundled electricity services may lead system operation closer to its security boundaries resulting in smaller operating safety margins. The competitive environment is expected to lead to lower price rates for customers and higher efficiency for power suppliers in the long run. Under this deregulated environment, security assessment and pricing of transmission services have become important issues in power systems. This dissertation provides new methods for power system security assessment and transmission pricing. In power system security assessment, the following issues are discussed (1) The description of probabilistic methods for power system security assessment; (2) The computation time of simulation methods; (3) on-line security assessment for operation. A probabilistic method using Monte-Carlo simulation is proposed for power system security assessment. This method takes into account dynamic and static effects corresponding to contingencies. Two different Kohonen networks, Self-Organizing Maps and Learning Vector Quantization, are employed to speed up the probabilistic method. The combination of Kohonen networks and Monte-Carlo simulation can reduce computation time in comparison with straight Monte-Carlo simulation. A technique for security assessment employing Bayes classifier is also proposed. This method can be useful for system operators to make security decisions during on-line power system operation. This dissertation also suggests an approach for allocating transmission transaction costs based on reliability benefits in transmission services. The proposed method shows the transmission transaction cost of reliability benefits when transmission line capacities are considered. The ratio between allocation by transmission line

  20. A Study on the Application for Enhancing the Transmission Capability of the KEPCO Power System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Han; Kwon, Tea Won; Whang, Jong Young; Lee, Gun Joon; Kim, Tae Hoon; Chang, Byung Hoon; Min, Wan Ki [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Park, Young Moon; Park, Jong Gun [Seoul National University, Seoul (Korea, Republic of); Kim, Gun Joong [Chungnam National University, Taejon (Korea, Republic of); Oh, Tae Kwu; Choi, Kwu Hyung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    Investigation of stability for power system in 2000 year and 2006 year by using the analysis of real power system. Comparative investigation of the conventional transmission line upgrading methods such as HVDC, HOP, new conductor scheme. Investigation of FACTS, the recent transmission line upgrading method, with respect to the aspect of technique and cost and effect analysis when this method is applied to real power system. Development of the evaluation method of transmission type that should be considered when above method is applied to real power system with respect to aspect of technique and cost. Development of a long-range plan for the transmission capacity upgrading and the evaluation method of reliability. (author).

  1. Hybrid mathematical and rule-based system for transmission network planning in open access schemes

    Energy Technology Data Exchange (ETDEWEB)

    Kandil, M. S. [Electrical Department, Mansura University, (Egypt); EI-Debeiky, S. M. [Electrical Department, Ain Shams University, (Egypt); Hasanien, N. E. [Egyptian Electricity Authority, Studies and Researches Department, (Egypt)

    2001-09-01

    The paper presents a planning methodology using an application of a mathematical and a rule-based expert system (ES) to expand the transmission network in open access schemes. In this methodology, the ES suggests a realistic set of generation additions with proper economic signals to the participants, before proceeding with the transmission expansion. A feasible list of transmission alternatives is then assumed to accommodate the proposals for generation. A mathematical method is performed based on marginal cost allocation to optimise the location for the new generation and its transmission expansion scheme simultaneously for each alternative. The optimum alternative, which minimises the overall system's cost function and satisfies the future demand under different operating conditions, is obtained. The ES interacts with the power system planning tools to produce the optimum expansion plan. A practical application is given to demonstrate the effectiveness of the developed prototype system. (Author)

  2. Training-based Channel Estimation for Signal Equalization and OPM in 16-QAM Optical Transmission Systems

    DEFF Research Database (Denmark)

    Pittalà, Fabio; Hauske, Fabian N.; Ye, Yabin;

    2012-01-01

    Efficient channel estimation for signal equalization and OPM based on short CAZAC sequences with QPSK and 8PSK constellation formats is demonstrated in a 224-Gb/s PDM 16-QAM optical linear transmission system....

  3. Interface of data transmission for a transcutaneous communication system using the human body as transmission medium.

    Science.gov (United States)

    Okamoto, Eiji; Kato, Yoshikuni; Seino, Kazuyuki; Mitamura, Yoshinori

    2012-03-01

    We have been developing a new transcutaneous communication system (TCS) that uses the human body as an electrical conductive medium. We studied an interface circuit of the TCS in order to optimize the leading data current into the human body effectively. Two types of LC circuits were examined for the interface circuit, one was an LC series-parallel circuit, and the other was a parallel-connected LC circuit. The LC series-parallel circuit connected to the body could be tuned to a resonant frequency, and the frequency was determined by the values of an external inductor and an external capacitor. Permittivity of the body did not influence the electrical resonance. Connection of the LC series-parallel circuit to the body degraded the quality factor Q because of the conductivity of the body. However, the LC parallel-connected circuit when connected to the body did not indicate electrical resonance. The LC series-parallel circuit restricts a direct current and a low-frequency current to flow into the body; thus, it can prevent a patient from getting a shock. According to the above results, an LC series-parallel circuit is an optimum interface circuit between the TCS and the body for leading data current into the body effectively and safely.

  4. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    Science.gov (United States)

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.

  5. System Design for Ocean Sensor Data Transmission Based on Inductive Coupling

    Science.gov (United States)

    Xu, Ming; Liu, Fei; Zong, Yuan; Hong, Feng

    Ocean observation is the precondition to explore and utilize ocean. How to acquire ocean data in a precise, efficient and real-time way is the key question of ocean surveillance. Traditionally, there are three types of methods for ocean data transmission: underwater acoustic, GPRS via mobile network and satellite communication. However, none of them can meet the requirements of efficiency, accuracy, real-time and low cost at the same time. In this paper, we propose a new wireless transmission system for underwater sensors, which established on FGR wireless modules, combined with inductive coupling lab and offshore experiments confirmed the feasibility and effectiveness of the proposed wireless transmission system.

  6. Electrical transmission systems and smart grids selected entries from the encyclopedia of sustainability science and technology

    CERN Document Server

    Begovic, Miroslav M

    2012-01-01

    Electric transmission networks are among the largest human-made engineering systems: For example, the transmission network in the United States covers over 300,000 km of lines and is served by 500 companies (electric utilities). In sharp contrast to the very incremental developments of the last century, transmission and control technologies experienced a major breakthrough at the beginning of the 21st century. The rapid growth of new energy generation technologies (renewables), significant advances in information processing applied to system monitoring, planning, operation, control, and protec

  7. Singing voice outcomes following singing voice therapy.

    Science.gov (United States)

    Dastolfo-Hromack, Christina; Thomas, Tracey L; Rosen, Clark A; Gartner-Schmidt, Jackie

    2016-11-01

    The objectives of this study were to describe singing voice therapy (SVT), describe referred patient characteristics, and document the outcomes of SVT. Retrospective. Records of patients receiving SVT between June 2008 and June 2013 were reviewed (n = 51). All diagnoses were included. Demographic information, number of SVT sessions, and symptom severity were retrieved from the medical record. Symptom severity was measured via the 10-item Singing Voice Handicap Index (SVHI-10). Treatment outcome was analyzed by diagnosis, history of previous training, and SVHI-10. SVHI-10 scores decreased following SVT (mean change = 11, 40% decrease) (P singing lessons (n = 10) also completed an average of three SVT sessions. Primary muscle tension dysphonia (MTD1) and benign vocal fold lesion (lesion) were the most common diagnoses. Most patients (60%) had previous vocal training. SVHI-10 decrease was not significantly different between MTD and lesion. This is the first outcome-based study of SVT in a disordered population. Diagnosis of MTD or lesion did not influence treatment outcomes. Duration of SVT was short (approximately three sessions). Voice care providers are encouraged to partner with a singing voice therapist to provide optimal care for the singing voice. This study supports the use of SVT as a tool for the treatment of singing voice disorders. 4 Laryngoscope, 126:2546-2551, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Transmission Dynamics of a Driven Two-Level System Dissipated by Leads

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ping; FAN Wen-Bin; ZHAO Xian-Geng

    2001-01-01

    We study the transmission dynamics of a driven two-level system dissipated by the two leads. Using the nonequilibrium Green function, we derive an analytical transmission formula for an electron incident from the left lead,through the double quantum dots, to the right lead. The Landauer-type conductance and current are also given.A discussion of the internal tunnelling dynamics reveals crucial effects of the localization and delocalization on the transport of the system.

  9. The Numerical Analysis of Transmission Tower-Line System Wind-Induced Collapsed Performance

    OpenAIRE

    Zhuoqun Zhang; Hongnan Li; Gang Li; Wenming Wang; Li Tian

    2013-01-01

    The numerical simulation of transmission tower-line systems' progressive collapse performance is considered as a major research hotspot and significant project, due to the increasing number of wind-induced collapse accidents recently. In this study, the finite element models for single tower and transmission tower-line system were established to simulate wind-induced progressive collapse by birth-to-death element technique in ABAQUS/Explicit. The wind field, based on the Kaimal fluctuating wi...

  10. Simulation on Dual-stream Transmission System of Unmanned Tracked Armored Vehicle Using ADAMS

    Directory of Open Access Journals (Sweden)

    Sun Wei

    2015-01-01

    Full Text Available For the dual-stream transmission system of unmanned tracked armored vehicle, simulation analysis is carried out. Using SolidWorks to establish three-dimensional model of its chassis, the result of the simulation is processed in AdAMS/Solver. The simulation results are showed in lines. Comparative analysis for each simulation lines is conducted, and it verifies the feasibility of the dual-stream transmission system.

  11. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj;

    2010-01-01

    power transmission options with HVDC systems are under consideration. In this paper, a comparison between a conventional HVAC transmission system and a HVDC system equipped with modular voltage source converters is provided. The comparison is based on the total energy transmission capability...

  12. Transmission systems expansion planning considering security and generation programming plans

    OpenAIRE

    Irenio de Jesus Silva Junior

    2005-01-01

    Resumo: Este trabalho apresenta algumas propostas para solucionar o problema de planejamento da expansão de sistemas de transmissão, estático e multiestágio, considerando restrições de segurança - critério de segurança (n_1), assim como para o planejamento da expansão de um sistema elétrico que satisfaça simultaneamente vários planos de programação da geração pré-especificados. Visando superar deficiências na determinação de soluções ótimas para sistemas de grande porte quando se usa métodos ...

  13. Massive WDM and TDM Soliton Transmission Systems : a ROSC Symposium

    CERN Document Server

    2002-01-01

    This book summarizes the proceedings of the invited talks presented at the “International Symposium on Massive TDM and WDM Optical Soliton Tra- mission Systems” held in Kyoto during November 9–12, 1999. The symposium is the third of the series organized by Research Group for Optical Soliton C- munications (ROSC) chaired by Akira Hasegawa. The research group, ROSC, was established in Japan in April 1995 with a support of the Japanese Ministry of Post and Telecommunications to promote collaboration and information - change among communication service companies, communication industries and academic circles in the theory and application of optical solitons. The symposium attracted enthusiastic response from worldwide researchers in the field of soliton based communications and intensive discussions were made. In the symposium held in 1997, new concept of soliton transmission based on dispersion management of optical fibers were presented. This new soliton is now called the dispersion managed soliton. The p...

  14. Single Ended Fault Location Estimation for EHV Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qing-chao张庆超; LI Hui李晖; D. W. P. Thomas

    2004-01-01

    A novel numerical algorithm for fault location estimation of single-phase-to-earth fault on EHV transmission lines is presented in this paper. The method is based on one-terminal voltage and current data and is used in a procedure that provides the automatic determination of faulted types and phases, rather than requires engineer to specify them. The loop and nodal equations comparing the faulted phase to non-faulted phases of multi-parallel lines are introduced in the fault location estimation models, in which source impedance of remote end is not involved. Precise algorithms of locating fault are derived. The effect of load flow and fault resistance,on the location accuracy, are effectively eliminated. The algorithms are demonstrated by digital computer simulations.

  15. 移动机器人实时语音控制的实现%Realization on the real-time voice control system for mobile robot

    Institute of Scientific and Technical Information of China (English)

    高美娟; 杨智鑫; 田景文

    2011-01-01

    Based on the study of speech recognition algorithms, the real-time voice control system for mobile robot has been designed and realized. Dynamic Time warping (DTW) algorithm was chosen for this system, and the programming has been finished with VC platform. To ensure the real-time property of the system, the automatic record system with voice switch was designed. The experiment confirmed that this system shows good effect in real-time speech control%通过对语音识别过程的研究,设计并制作开发了1套基于移动机器人的实时语音控制系统.采用了动态时间规整(DTW)算法作为核心识别方法,并使用VC完成了对各部分的软件编程.其中为了保证系统的实时性,特别设计了带有声控开关的自动录音系统.通过最后的实验证实了,系统可以很好的完成实时语音控制.

  16. System Reliability Evaluation of Data Transmission in Commercial Banks with Multiple Branches

    Directory of Open Access Journals (Sweden)

    Yi-Kuei Lin

    2014-01-01

    Full Text Available The main purpose of this paper is to assess the system reliability of electronic transaction data transmissions made by commercial banks in terms of stochastic flow network. System reliability is defined as the probability of demand satisfaction and it can be used to measure quality of service. In this paper, we study the system reliability of data transmission from the headquarters of a commercial bank to its multiple branches. The network structure of the bank and the probability of successful data transmission are obtained through the collection of real data. The system reliability, calculated using the minimal path method and the recursive sum of disjoint products algorithm, provides banking managers with a view to comprehend the current state of the entire system. Besides, the system reliability can be used not only as a measurement of quality of service, but also an improvement reference of the system by adopting sensitivity analysis.

  17. Clinical Voices - an update

    DEFF Research Database (Denmark)

    Fusaroli, Riccardo; Weed, Ethan

    Anomalous aspects of speech and voice, including pitch, fluency, and voice quality, are reported to characterise many mental disorders. However, it has proven difficult to quantify and explain this oddness of speech by employing traditional statistical methods. In this talk we will show how the t...... the temporal dynamics of the voice in Asperger's patients enable us to automatically reconstruct the diagnosis, and assess the Autism quotient score. We then generalise the findings to Danish and American children with autism....

  18. [Study on transmission efficiency of interference system in spatially modulated Fourier transform spectrometer].

    Science.gov (United States)

    Lü, Jin-Guang; Liang, Jing-Qiu; Liang, Zhong-Zhu; Qin, Yu-Xin; Tian, Chao

    2013-03-01

    The reflection of the optic system surface and the absorption of the infrared material could reduce the transmission of the incident light in spatially modulated Fourier transform infrared spectrometer. Through the calculation of the transmission function of the interference system and the simulation of the interferogram image and recovered spectrum affected by transmission function, it was indicated that the contrast of the interferogram image declined and the spectral line intensity weakened. The theoretical analysis shows that the contrast of the interferogram image was related to the intensity reflectance of the anti-reflection film, and the attenuation of the spectrum was determined by transmission efficiency concerned with intensity reflectance R1 of the anti-reflection film, intensity reflectance R2 of the beam splitter film, and the absorption coefficient. By means of the analysis and argumentation, the absorption of the material could be ignored in our investigative wave band. So the transmission efficiency was determined only by R1 and R2. Then taking the transmission efficiency as the design target, according to the transmission required by system, the tolerance of the R1 and R2 could be gained.

  19. Online Location of Faults on AC Cables in Underground Transmission Systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær

    parts; The preliminaries, a part which deals with the use of impedance-based fault location methods on crossbonded cables, a part which deals with travelling wave-based fault location, a part listing the conclusions and contributions of the thesis and an appendix. A state-of-the-art analysis......A transmission grid is normally laid out as an almost pure overhead line (OHL) network. The introduction of transmission voltage level XLPE cables and the increasing interest in the environmental impact of OHL has resulted in an increasing interest in the use of underground cables on transmission...... level. In Denmark for instance, the entire 150 kV, 132 kV and 220 kV and parts of the 400 kV transmission network will be placed underground before 2030. To reduce the operating losses of a cable-based transmission system, crossbonding schemes are normally used. The use of crossbonding introduces new...

  20. LQR Feedback Control Development for Wind Turbines Featuring a Digital Fluid Power Transmission System

    DEFF Research Database (Denmark)

    Pedersen, Niels Henrik; Johansen, Per; Andersen, Torben O.

    2016-01-01

    Research within digital fluid power (DFP) transmissions is receiving an increased attention as an alternative to conventional transmission technologies. The use of DFP displacement machines entail a need for applicable control algorithms. However, the design and analysis of controllers...... for such digital systems are complicated by its non-smooth behavior. In this paper a control design approach for a digital displacement machine® is proposed and a performance analysis of a wind turbine using a DFP transmission is presented. The performance evaluation is based on a dynamic model of the transmission...... invariant model. Using full-field flow wind profiles as input, the design approach and control performance is verified by simulation in the dynamic model of the wind turbine featuring the DFP transmission. Additionally, the performance is compared to that of the conventional NREL reference turbine...

  1. Long-Haul Dense Space Division Multiplexed Transmission over Low-Crosstalk Heterogeneous 32-Core Transmission Line Using Partial Recirculating Loop System

    DEFF Research Database (Denmark)

    Mizuno, Takayuki; Shibahara, Kohki; Ye, Feihong

    2017-01-01

    In this paper, we present long-haul 32-core dense space division multiplexed (DSDM) unidirectional transmission over a single-mode multicore transmission line. We developed a low-crosstalk heterogeneous 32-core fiber with a square lattice arrangement, and a novel partial recirculating loop system...

  2. Effects of Medications on Voice

    Science.gov (United States)

    ... ENT Doctor Near You Effects of Medications on Voice Effects of Medications on Voice Patient Health Information ... entnet.org . Could Your Medication Be Affecting Your Voice? Some medications including prescription, over-the-counter, and ...

  3. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    Energy Technology Data Exchange (ETDEWEB)

    Liun, Edwaren, E-mail: edwaren@batan.go.id; Suparman, E-mail: edwaren@batan.go.id [Centre for Nuclear Energy Development, National Nuclear Energy Agency of Indonesia (Indonesia)

    2014-09-30

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  4. Load speed regulation in compliant mechanical transmission systems using feedback and feedforward control actions.

    Science.gov (United States)

    Raul, P R; Dwivedula, R V; Pagilla, P R

    2016-07-01

    The problem of controlling the load speed of a mechanical transmission system consisting of a belt-pulley and gear-pair is considered. The system is modeled as two inertia (motor and load) connected by a compliant transmission. If the transmission is assumed to be rigid, then using either the motor or load speed feedback provides the same result. However, with transmission compliance, due to belts or long shafts, the stability characteristics and performance of the closed-loop system are quite different when either motor or load speed feedback is employed. We investigate motor and load speed feedback schemes by utilizing the singular perturbation method. We propose and discuss a control scheme that utilizes both motor and load speed feedback, and design an adaptive feedforward action to reject load torque disturbances. The control algorithms are implemented on an experimental platform that is typically used in roll-to-roll manufacturing and results are shown and discussed.

  5. Analysis of Interline Power Flow Controller (IPFC Location in Power Transmission Systems

    Directory of Open Access Journals (Sweden)

    Amir Kahyaei

    2011-07-01

    Full Text Available The Interline Power Flow Controller (IPFC is one of the latest generation Flexible AC Transmission Systems (FACTS controller used to control power flows of multiple transmission lines. The aim of this paper is investigation of the effect of location of IPFC on profile of voltage and real and reactive power flow in transmission lines in power system. This model is incorporated in Newton- Raphson (NR power flow algorithm to study the power flow control in transmission lines in which IPFC is placed. A program in MATLAB/SIMULINK has been written in order to extend conventional NR algorithm based on this model. Numerical results are carried out on a standard power system. The results without and with IPFC for various locations are compared in terms of voltages, active and reactive power flows to demonstrate the performance of the IPFC model.

  6. High-voltage transmission tower-line system subjected to disaster loads

    Institute of Scientific and Technical Information of China (English)

    LI Hongnan; BAI Haifeng

    2006-01-01

    The high-voltage power transmission system is an important lifeline structure. It is significant for wide researches on the features and ability of the system subjected to earthquake and environmental loads. The promising prosperity of the system has been demonstrated around the world. The corresponding advances of the system with respect to the mechanism of loading action, analytical methods, experimental research measurements, structural vibration control, fatigue damage, lifetime prediction, and design methods are comprehensively discussed herein. Finally, further research work on dynamic response characteristics of high-voltage transmission towerline system in the near future is predicted.

  7. 47 CFR 73.1350 - Transmission system operation.

    Science.gov (United States)

    2010-10-01

    ... regarding antenna tower lighting, and § 73.69 regarding the parameters of an AM directional antenna system... system tolerances, see § 73.62; (2) AM directional antenna monitoring points, see § 73.158; (3) TV...

  8. Microwave power transmission system workshop, session on solid state

    Science.gov (United States)

    Finnell, W.

    1980-01-01

    The development of solid state technology for solar power satellite systems is briefly addressed. The economic advantages of solid state based systems are listed along with some conclusions and issues regarding specific design concepts.

  9. Electrical Collection and Transmission Systems for Offshore Wind Power: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Green, J.; Bowen, A.; Fingersh, L.J.; Wan, Y.

    2007-03-01

    The electrical systems needed for offshore wind farms to collect power from wind turbines--and transmit it to shore--will be a significant cost element of these systems. This paper describes the development of a simplified model of the cost and performance of such systems.

  10. Pulse position modulation for a subcarrier-multiplexed optical fiber transmission system

    Science.gov (United States)

    Wickramasinghe, V. R.; Ghassemlooy, Zabih F.

    1996-11-01

    Subcarrier multiplexed (SCM) optical network s offer a near to medium term alternative solution over high cost, evolving digital technology to distribute broadband services. Majority of existing systems are based on analogue optical transmission techniques and their principle disadvantage is the sensitivity to noise and system nonlinearities. Therefore, conventional SCM systems impose stringent noise and linearity requirements and as a result their performance is limited. A simple and attractive solution is to introduce an appropriate second stage modulator in order to improve the receiver sensitivity, hence the system performance.In this paper a SCM optical transmission system employing pulse position modulation as a second stage modulator, for transmission of video, audio and data channels is reported. Signal to noise ratio measurements obtained shows an improvement in optical receiver sensitivity compared with standard SCM systems.

  11. WHEEL CHAIR USING VOICE RECOGNITION

    OpenAIRE

    Manish Kumar Yadav*; Rajat Kumar; Santosh Yadav; Ravindra Prajapati; Prof. Kshirsagar

    2016-01-01

    The wide spread prevalence of lost limbs and sensing system is of major concern in present day due to wars, accident, age and health problems. This Omni-directional wheelchair was designed for the less able elderly to move more flexibly in narrow spaces, such as elevators or small aisle. The wheelchair is developed to help disabled patients by using speech recognition system to control the movement of wheelchair in different directions by using voice commands and also the simple movement of t...

  12. Investigations and system design for simultaneous energy and data transmission through inductively coupled resonances

    Science.gov (United States)

    Schmidt, C.; Lloret Fuentes, E.; Buchholz, M.

    2015-11-01

    Wireless Power Transfer (WPT) with simultaneous data transmission through coupled magnetic resonators is investigated in this paper. The development of this system is dedicated to serve as a basis for applications in the field of Ambient Assisted Living (AAL), for example tracking vital parameters remotely, charge and control sensors and so on. Due to these different scenarios we consider, it is important to have a system which is reliable under the circumstance of changing positioning of the receiving device. State of the art radio systems would be able to handle this. Nevertheless, energy harvesting from far field sources is not sufficient to power the devices additionally on mid-range distances. For this reason, coupled magnetic resonant circuits are proposed as a promising alternative, although suffering from more complex positioning dependency. Based on measurements on a simple prototype system, an equivalent circuit description is used to model the transmission system dependent on different transmission distances and impedance matching conditions. Additionally, the simulation model is used to extract system parameters such as coupling coefficients, coil resistance and self-capacitance, which cannot be calculated in a simple and reliable way. Furthermore, a mathematical channel model based on the schematic model has been built in MATLAB©. It is used to point out the problems occurring in a transmission system with variable transmission distance, especially the change of the passband's centre frequency and its bandwidth. Existing solutions dealing with this distance dependent behaviour, namely the change of the transmission frequency dependent on distance and the addition of losses to the resonators to increase the bandwidth, are considered as not inventive. First, changing the transmission frequency increases the complexity in the data transmission system and would use a disproportional total bandwidth compared to the actually available bandwidth

  13. Optimisation of Transmission Systems by use of Phase Shifting Transformers

    Energy Technology Data Exchange (ETDEWEB)

    Verboomen, J.

    2008-10-13

    In this thesis, transmission grids with PSTs (Phase Shifting Transformers) are investigated. In particular, the following goals are put forward: (a) The analysis and quantification of the impact of a PST on a meshed grid. This includes the development of models for the device; (b) The development of methods to obtain optimal coordination of several PSTs in a meshed grid. An objective function should be formulated, and an optimisation method must be adopted to solve the problem; and (c) The investigation of different strategies to use a PST. Chapter 2 gives a short overview of active power flow controlling devices. In chapter 3, a first step towards optimal PST coordination is taken. In chapter 4, metaheuristic optimisation methods are discussed. Chapter 5 introduces DC load flow approximations, leading to analytically closed equations that describe the relation between PST settings and active power flows. In chapter 6, some applications of the methods that are developed in earlier chapters are presented. Chapter 7 contains the conclusions of this thesis, as well as recommendations for future work.

  14. Effect of Tooth Profile Modification on Vibration of Power Split Gear Transmission System

    Institute of Scientific and Technical Information of China (English)

    He Lin

    2016-01-01

    Based on Newton's second law, the bend⁃torsion⁃shaft coupling nonlinear dynamic model and equations of power split gear transmission system are established. According to the principle of tooth profile modification, the tooth profile modification is considered as time⁃varying gear backlash function acting along the line of action. Then the dynamic functions are solved by using Runge⁃Kutta numerical method. After analyzing the effect of tooth profile modification quantity( TPMQ) and relative tooth profile modification length( TPML) to the nonlinear dynamic characteristics of power split gear transmission, the following conclusions are drawn:①The TPMQ of a certain stage transmission affects the vibration of its own stage more significantly than the other stage, and the coupling effect between two stages can be ignored usually in the modification design;②If the first stage TPMLs are less than 0.3, the influence of the first stage TPMLs to the first stage transmission vibration is much more greatly than the influence of the second stage TPMLs to the first stage transmission vibration, or else both the first and second stage TPMLs affect the first stage transmission vibration largely. The same is true for the second stage TPMLs, and the cutoff value is 0. 2; ③The TPMQ affects the vibration of power split gear transmission system more principally than the TPML, and should be top⁃priority in the modification design.

  15. Expedience of application of MIMO systems of digital communication for complex chaotic signal transmission

    OpenAIRE

    Vasyuta, K. S.; Zakharchenko, I. V.; Ozerov, S. V.

    2015-01-01

    The paper discusses the expediency of using MIMO digital systems for transmission of chaotic signals as a way of partial solution of electromagnetic compatibility of perspective broadband communication systems with an existing class of narrow-band radio-technical systems.

  16. 集群录音系统在营销语音监控中的应用%Application of the Cluster Recording System in the Marketing Voice Monitoring System

    Institute of Scientific and Technical Information of China (English)

    滕波; 蒋钟

    2014-01-01

    通过分析分子营销语音监控的现状,设计一种基于信息网的集群录音系统,并介绍了该系统的架构和具体软硬件配置,以及它的经济和社会效益。集群录音系统实现了对营销客服电话的统一监控和管理。%By analyzing the current situation of the marketing voice monitoring,this paper presents a cluster recording system of information network based on the marketing voice monitoring system,and introduces the architecture of cluster recording system and the specific hardware and software configura-tion,and its economic and social benefits.The system can help to have a unified monitoring and manage-ment to the marketing clients’telephones.

  17. Optimal transmission strategy for spatially correlated MIMO systems with channel statistical information

    Institute of Scientific and Technical Information of China (English)

    ZHAO Zhen-shan; XU Guo-zhi

    2007-01-01

    In real multiple-input multiple-output (MIMO) systems, the perfect channel state information (CSI) may be costly or impossible to acquire. But the channel statistical information can be considered relatively stationary during long-term transmission.The statistical information can be obtained at the receiver and fed back to the transmitter and do not require frequent update. By exploiting channel mean and covariance information at the transmitter simultaneously, this paper investigates the optimal transmission strategy for spatially correlated MIMO channels. An upper bound of ergodic capacity is derived and taken as the performance criterion. Simulation results are also given to show the performance improvement of the optimal transmission strategy.

  18. Transmission Needs In A Fully Renewable Pan-European Electricity System

    DEFF Research Database (Denmark)

    Rodriguez, Rolando A.; Bruun Andresen, Gorm; Becker, Sarah;

    2012-01-01

    Based on high-resolution weather and electrical load data, the transmission needs for a fully renewable pan-European electricity system are determined. The ideal cross-border transmission capacities turn out to be a factor 10 larger than those of today. A reduction of cross-border transmission...... capacities lead to a non-linear increase of balancing needs. A good compromise turns out to be a capacity layout, which is a factor 5 larger than today’s one. On average each country will only be able to import / export 40% of its residual demand / renewable excess generation....

  19. Design, control and application of modular multilevel converters for HVDC transmission systems

    CERN Document Server

    Sharifabadi, Kamran; Nee, Hans-Peter; Norrga, Staffan; Teodorescu, Remus

    2016-01-01

    Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical and economic requirements and optimization options, fault management, dynamic and transient stability. Finally, the third chapter explores the applications of MMC in HVDC transmission and Multi Terminal configurations, including Supergrids.

  20. Comparison of post menopausal voice changes across professional and non-professional users of the voice

    Directory of Open Access Journals (Sweden)

    Pallavi Vishwas Sovani

    2010-12-01

    Full Text Available Menopause effects a permanent change in certain body functions, one of them being voice. Moreover, if the voice is used continuously as a part of one’s occupation, this may further impact postmenopausal voice changes. The present study investigated the impact of menopause and professional voice use, and their interaction effect, on the voice. 92 women were classified into reproductive (52 and postmenopausal (40. Each group was divided into Level II (teachers and Level IV (clerks of Koufman and Isaacson’s (1991 classification. Acoustic parameters were analyzed using the VisiPitch III software. Aerodynamic parameters were manually calculated. The VHI (Voice Handicap Index was also included to improve the face validity of the study. Results suggest that Fo, SFo and MPT reduce post menopause while NHR and VTI increase. Some changes are accelerated in teachers as compared to clerks while some are decelerated. VHI scores of teachers are significantly greater than clerks, though not significantly different across menopause. Thus the presence or absence of voice use in one’s profession differentially affects postmenopausal changes. The study has implications in improving the condition of teachers in India, developing norms for menopausal changes and modifying allowable limits for voice recognition systems in future.

  1. Telemedicine to Promote Patient Safety: Use of Phone-Based Interactive Voice-Response System to Reduce Adverse Safety Events in Pre-dialysis CKD.

    Science.gov (United States)

    Weiner, Shoshana; Fink, Jeffery C

    2017-01-01

    CKD patients have several features conferring on them a high risk of adverse safety events, which are defined as incidents with unintended harm related to processes of care or medications. These characteristics include impaired kidney function, polypharmacy, and frequent health system encounters. The consequences of such events in CKD can include new or prolonged hospitalization, accelerated kidney function loss, acute kidney injury, ESRD, and death. Health information technology administered via telemedicine presents opportunities for CKD patients to remotely communicate safety-related findings to providers for the purpose of improving their care. However, many CKD patients have limitations that hinder their use of telemedicine and access to the broad capabilities of health information technology. In this review, we summarize previous assessments of the pre-dialysis CKD populations' proficiency in using telemedicine modalities and describe the use of interactive voice-response system to gauge the safety phenotype of the CKD patient. We discuss the potential for expanded interactive voice-response system use in CKD to address the safety threats inherent to this population.

  2. Design of the Eelectron Cyclotron Resonance Heating Transmission System for HL-2A

    Institute of Scientific and Technical Information of China (English)

    周俊; 刘永

    2004-01-01

    HL-2A will be equipped with a 75 GHz/1 MW/1s electron cyclotron resonance heating (ECRH) system. The paper describes the design of the transmission system, which is made up of a transmission line, an equatorial launcher and a measureing system. The paper describes in detail the design of main components of the system such as, waveguides, ellipsoidal surface mirrors, chemical vapor (CVD) diamond window, steering mirror, and new directional coupler with a k-spectrometer. The newly-designed launcher can make the beam steer poloidally to deposit energy in different locations.

  3. Coordinated Transmissions to Direct and Relayed Users in Wireless Cellular Systems

    DEFF Research Database (Denmark)

    Thai, Chan; Popovski, Petar; Kaneko, Megumi

    2011-01-01

    The ideas of wireless network coding at the physical layer promise high throughput gains in wireless systems with relays and multi–way traffic flows. This gain can be ascribed to two principles: (1) joint transmission of multiple communication flows and (2) usage of a priori information to cancel...... the interference. In this paper we use these principles to devise new transmission schemes in wireless cellular systems that feature both users served directly by the base stations (direct users) and users served through relays (relayed users). We present four different schemes for coordinated transmission...... of uplink and downlink traffic in which one direct and one relayed user are served. These schemes are then used as building blocks in multi–user scenarios, where we present several schemes for scheduling pairs of users for coordinated transmissions. The optimal scheme involves exhaustive search of the best...

  4. The design and analysis of channel transmission communication system of XCTD profiler

    Science.gov (United States)

    Zheng, Yu; Wang, Xiao-Rui; Jin, Xiang-Yu; Song, Guo-Min; Shang, Ying-Sheng; Li, Hong-Zhi

    2016-10-01

    In this paper, a channel transmission communication system of expendable conductivity-temperature-depth is established in accordance to the operation characteristics of the transmission line to more accurately assess the characteristics of deep-sea abandoned profiler channel. The wrapping inductance is eliminated to maximum extent through the wrapping pattern of the underwater spool and the overwater spool and the calculation of the wrapping diameter. The feasibility of the proposed channel transmission communication system is verified through theoretical analysis and practical measurement of the transmission signal error rate in the amplitude shift keying (ASK) modulation. The proposed design provides a new research method for the channel assessment of complex abandoned measuring instrument and an important experiment evidence for the rapid development of the deep-sea abandoned measuring instrument.

  5. The design and analysis of channel transmission communication system of XCTD profiler.

    Science.gov (United States)

    Zheng, Yu; Wang, Xiao-Rui; Jin, Xiang-Yu; Song, Guo-Min; Shang, Ying-Sheng; Li, Hong-Zhi

    2016-10-01

    In this paper, a channel transmission communication system of expendable conductivity-temperature-depth is established in accordance to the operation characteristics of the transmission line to more accurately assess the characteristics of deep-sea abandoned profiler channel. The wrapping inductance is eliminated to maximum extent through the wrapping pattern of the underwater spool and the overwater spool and the calculation of the wrapping diameter. The feasibility of the proposed channel transmission communication system is verified through theoretical analysis and practical measurement of the transmission signal error rate in the amplitude shift keying (ASK) modulation. The proposed design provides a new research method for the channel assessment of complex abandoned measuring instrument and an important experiment evidence for the rapid development of the deep-sea abandoned measuring instrument.

  6. Hole-assisted multicore optical fiber for next generation telecom transmission systems

    Science.gov (United States)

    Ziolowicz, A.; Szymanski, M.; Szostkiewicz, L.; Tenderenda, T.; Napierala, M.; Murawski, M.; Holdynski, Z.; Ostrowski, L.; Mergo, P.; Poturaj, K.; Makara, M.; Slowikowski, M.; Pawlik, K.; Stanczyk, T.; Stepien, K.; Wysokinski, K.; Broczkowska, M.; Nasilowski, T.

    2014-08-01

    We present a multicore fiber dedicated for next generation transmission systems. To overcome the issue of multicore fibers' integration with existing transmission systems, the fiber is designed in such a way that the transmission parameters for each core (i.e., chromatic dispersion, attenuation, bending loss, etc.) are in total accordance with the obligatory standards for telecommunication single core fibers (i.e., ITU-T G.652 and G.657). We show the results of numerical investigations and measurements carried out for the fabricated fiber, which confirm low core-to-core crosstalk and compatibility with standard single-core single-mode transmission links making the fiber ready for implementation in the near future.

  7. Research on WDM optical fiber transmission system based on fiber Raman amplifier

    Institute of Scientific and Technical Information of China (English)

    Fei Xue(薛飞); Kun Qiu(邱昆); Yue Chen(陈玥)

    2003-01-01

    After wavelength division multiplexing (WDM) optical fiber transmission system based on fiber Raman amplifier (FRA) is investigated in detail, the influence of the collocation of dispersion compensation fiber (DCF), the dispersion coefficient, dispersion slope (DS), effective core area, nonlinear index, length of FRA, launch power and the bandwidth of Bessel filter on bit error rate (BER) is deduced. The influence of Rayleigh backscattering noise on optical signal noise ratio (OSNR) is also investigated, which affects the performance of long haul transmission badly. The result indicates that the broadband long haul transmission can be realized through the reasonable design of the fiber. The result is useful to the optimal design of the WDM optical fiber transmission system based on FRA.

  8. Coordinated Transmissions to Direct and Relayed Users in Wireless Cellular Systems

    CERN Document Server

    Thai, Chan Dai Truyen; Kaneko, Megumi; de Carvalho, Elisabeth

    2010-01-01

    The ideas of wireless network coding at the physical layer promise high throughput gains in wireless systems with relays and multi-way traffic flows. This gain can be ascribed to two principles: (1) joint transmission of multiple communication flows and (2) usage of \\emph{a priori} information to cancel the interference. In this paper we use these principles to devise new transmission schemes in wireless cellular systems that feature both users served directly by the base stations (direct users) and users served through relays (relayed users). We present four different schemes for \\emph{coordinated transmission} of uplink and downlink traffic in which one direct and one relayed user are served. These schemes are then used as building blocks in multi-user scenarios, where we present several schemes for scheduling pairs of users for coordinated transmissions. The optimal scheme involves exhaustive search of the best user pair in terms of overall rate. We propose several suboptimal scheduling schemes, which perf...

  9. Analysis of Basic Transmission Networks for Integrated Ship Control Systems

    DEFF Research Database (Denmark)

    Hansen, T.N.; Granum-Jensen, M.

    1993-01-01

    Description of a computer network for Integrated Ship Control Systems which is going to be developed as part of an EC-project. Today equipment of different make are not able to communicate with each other because most often each supplier of ISC systems has got their own proprietary network.....

  10. Kansas Communication and Instruction System through Fiber-Optic Transmission.

    Science.gov (United States)

    Kansas State Dept. of Education, Topeka.

    Schools and communities will restructure as they move into the next decade. The success of this restructuring will be dependent upon access to and sharing of quality teaching and information through an expanded communication system. One of the major two-way interactive technologies is the fiber-optic cable: a delivery system that will provide…

  11. Guidelines for transient analysis in water transmission and distribution systems

    NARCIS (Netherlands)

    Pothof, I.W.M.; Karney, B.W.

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent, mon

  12. Guidelines for transient analysis in water transmission and distribution systems

    NARCIS (Netherlands)

    Pothof, I.W.M.; Karney, B.W.

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent,

  13. Precision-analog fiber-optic transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Stover, G.

    1981-06-01

    This article describes the design, experimental development, and construction of a DC-coupled precision analog fiber optic link. Topics to be covered include overall electrical and mechanical system parameters, basic circuit organization, modulation format, optical system design, optical receiver circuit analysis, and the experimental verification of the major design parameters.

  14. Research of data transmission security in videoconference system

    Institute of Scientific and Technical Information of China (English)

    LIU Yan-long; WANG Chun-lei; SUN Zhi-tao

    2007-01-01

    Many coal enterprises have built the videoconference systems on their LAN(Local Area Network). As the development of these enterprises, their organizations are distributed over our country and even over the world. Therefore, the videoconference systems have to run over WAN (Wide Area Network). Normally, the structure of a videoconference system is center_division including MCU (multi control unit) and participants. No QoS and security assurance are available now because all videoconference system is based on TCP/IP. Therefore, the system stability is absolutely depended on the Network.This paper discussed how to anti ARP attacking. The method discussed in this paper is based on TCP/IP.

  15. Nonlinear phase noise in coherent optical OFDM transmission systems.

    Science.gov (United States)

    Zhu, Xianming; Kumar, Shiva

    2010-03-29

    We derive an analytical formula to estimate the variance of nonlinear phase noise caused by the interaction of amplified spontaneous emission (ASE) noise with fiber nonlinearity such as self-phase modulation (SPM), cross-phase modulation (XPM), and four-wave mixing (FWM) in coherent orthogonal frequency division multiplexing (OFDM) systems. The analytical results agree very well with numerical simulations, enabling the study of the nonlinear penalties in long-haul coherent OFDM systems without extensive numerical simulation. Our results show that the nonlinear phase noise induced by FWM is significantly larger than that induced by SPM and XPM, which is in contrast to traditional WDM systems where ASE-FWM interaction is negligible in quasi-linear systems. We also found that fiber chromatic dispersion can reduce the nonlinear phase noise. The variance of the total phase noise increases linearly with the bit rate, and does not depend significantly on the number of subcarriers for systems with moderate fiber chromatic dispersion.

  16. Voice Biometrics for Information Assurance Applications

    Science.gov (United States)

    2007-11-02

    verification capability). Approach #2: The individual speaker selects a test phrase (our approach) — In the NRL voice biomet - rics system, the...templates must be issued to all users. Approach #2: Unprocessed speech waveforms (our approach) — If the fingerprint-matching biomet - rics method stores...is that the amount of data to be stored is larger compared to the previous approach. The minimum amount of information we need to perform voice biomet

  17. Fatigue Prediction of a Gear Transmission System based on Vibro-Acoustic Measurements

    OpenAIRE

    Ahmaida, Anwar; Zhen, Dong; Gu, Fengshou.; Ball, Andrew

    2013-01-01

    Gearing components play a pivotal role in most power transmission mechanisms but their application in industry consistently results in significant disruption and losses due to gear failures. This emphasises the significance of condition monitoring and fault diagnostics techniques of gear transmission systems to enhance overall safety and operational reliability in order to minimise gearbox failure rates and their associated disruption and losses to industry. In a wide range of industrial cont...

  18. Reprint of “Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS”

    Science.gov (United States)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2013-01-01

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  19. Bio-Authentication based Secure Transmission System using Steganography

    CERN Document Server

    Zehra, Najme; Ahuja, Somya; Bansal, Shubha

    2010-01-01

    Biometrics deals with identity verification of an individual by using certain physiological or behavioral features associated with a person. Biometric identification systems using fingerprints patterns are called AFIS (Automatic Fingerprint Identification System). In this paper a composite method for Fingerprint recognition is considered using a combination of Fast Fourier Transform (FFT) and Sobel Filters for improvement of a poor quality fingerprint image. Steganography hides messages inside other messages in such a way that an "adversary" would not even know a secret message were present. The objective of our paper is to make a bio-secure system. In this paper bio-authentication has been implemented in terms of finger print recognition and the second part of the paper is an interactive steganographic system hides the user's data by two options- creating a songs list or hiding the data in an image.

  20. Investigation of EDFA Performance in 8 Channel WDM Transmission System

    OpenAIRE

    Lavrinoviča, I; Poriņš, J

    2015-01-01

    Erbium Doped Fiber Amplifier (EDFA) obtained a wide range of applications in research and commercial applications in optical fiber communication systems. It has been considered as an attractive solution because of several major advantages - low loss optical window of silica based fiber (1525-1565 nm), high energy efficiency (>50 %) and time constant enough to cover modulation noises. However, the presence of amplified spontaneous emission (ASE), the difficulty in implementing a WDM system - t...

  1. Review of structural design trends for extra high voltage transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Cook, L.H.J.; Coblenz, J.

    1964-01-01

    Viewed on a national basis, the anticipated investment in ehv transmission systems for the next few years is a major consideration. A conservative review of Canadian transmission construction programs indicates that at least 7,000 miles of transmission in the voltage range of 360 kV to 735 kV, representing an investment of over one billion dollars, will be built within the next ten years and that this figure could be doubled if a start is made on a national grid. The various technologies associated with transmission line design and construction have undergone tremendous changes during the last decade. The careful integration of all these advances into the ehv lines now being planned is essential if any major reduction in transmission costs is to be achieved. It is hoped that a program of applied research into the structural elements of a transmission system will be initiated as quickly as possible in order that the benefits of such a program may be reflected in material reductons in the cost of the extra high voltage systems now being conceived across Canada.

  2. Analytical investigation of the pericyclic variable-speed transmission system for helicopter main-gearbox

    Science.gov (United States)

    Saribay, Zihni Burcay

    In the recent years, there has been significant interest in the new developments and improvements of the rotorcraft transmission systems. The main goal of the rotorcraft transmission research is the reduction of overall gear train weight while maintaining the efficiency and reliability. The Pericyclic Variable-Speed Transmission (PVT) System is one of the potential candidates of the future rotorcraft drive trains to achieve these goals. Hence, this thesis explores the feasibility of the Pericyclic Variable Speed Transmission (PVT) for rotorcraft transmissions. The contributions of this research are grouped in two main categories. These two categories are in the component level and in the system level. These contributions are originated from the analysis of the Pericyclic Variable Speed (PVT) System. In the component level, a new concept of face-gear meshing is presented first time in the gear research field. The meshing of a face-gear with another face-gear is presented at high shaft angles as an alternative to bevel gears. The conjugacy of this new face-gear meshing concept is formulated and demonstrated. The geometry, unloaded mesh kinematics and loaded mesh kinematics of the conjugate meshing face-gear pair is analyzed. The physics behind the meshing face-gear teeth contact is revealed using theory of gearing, differentiable geometry and elastohydrodynamic lubrication theory. The existence of the lubricant film formation between the meshing teeth is demonstrated. The behavior of the sliding friction coefficient is analytically simulated through the meshing cycle. In the system level contributions, the Pericyclic Variable Speed (PVT) Transmission is presented as a new unique innovative gear train mechanism. The speed change capability is analyzed for rotorcraft demands. The power flow behavior is explored for its use in variable speed transmission systems. The established component level contributions are evaluated with the PVT at the system level. The efficiency

  3. Voiced Reading and Rhythm

    Institute of Scientific and Technical Information of China (English)

    詹艳萍

    2007-01-01

    Since voiced reading is an important way in learning English,rhythm is the most critical factor that enables to read beautifully.This article illustrates the relationship between rhythm and voiced reading,the importance of rhythm,and the methods to develop the sense of rhythm.

  4. Clinical Voices - an update

    DEFF Research Database (Denmark)

    Fusaroli, Riccardo; Weed, Ethan

    Anomalous aspects of speech and voice, including pitch, fluency, and voice quality, are reported to characterise many mental disorders. However, it has proven difficult to quantify and explain this oddness of speech by employing traditional statistical methods. In this talk we will show how...

  5. Borderline Space for Voice

    Science.gov (United States)

    Batchelor, Denise

    2012-01-01

    Being on the borderline as a student in higher education is not always negative, to do with marginalisation, exclusion and having a voice that is vulnerable. Paradoxically, being on the edge also has positive connections with integration, inclusion and having a voice that is strong. Alternative understandings of the concept of borderline space can…

  6. Voice and endocrinology

    Directory of Open Access Journals (Sweden)

    KVS Hari Kumar

    2016-01-01

    Full Text Available Voice is one of the advanced features of natural evolution that differentiates human beings from other primates. The human voice is capable of conveying the thoughts into spoken words along with a subtle emotion to the tone. This extraordinary character of the voice in expressing multiple emotions is the gift of God to the human beings and helps in effective interpersonal communication. Voice generation involves close interaction between cerebral signals and the peripheral apparatus consisting of the larynx, vocal cords, and trachea. The human voice is susceptible to the hormonal changes throughout life right from the puberty until senescence. Thyroid, gonadal and growth hormones have tremendous impact on the structure and function of the vocal apparatus. The alteration of voice is observed even in physiological states such as puberty and menstruation. Astute clinical observers make out the changes in the voice and refer the patients for endocrine evaluation. In this review, we shall discuss the hormonal influence on the voice apparatus in normal and endocrine disorders.

  7. Face the voice

    DEFF Research Database (Denmark)

    Lønstrup, Ansa

    2014-01-01

    will be based on a reception aesthetic and phenomenological approach, the latter as presented by Don Ihde in his book Listening and Voice. Phenomenologies of Sound , and my analytical sketches will be related to theoretical statements concerning the understanding of voice and media (Cavarero, Dolar, La...

  8. Ontario's Student Voice Initiative

    Science.gov (United States)

    Courtney, Jean

    2014-01-01

    This article describes in some detail aspects of the Student Voice initiative funded and championed by Ontario's Ministry of Education since 2008. The project enables thousands of students to make their voices heard in meaningful ways and to participate in student-led research. Some students from grades 7 to 12 become members of the Student…

  9. Impact of Utility-Scale Distributed Wind on Transmission-Level System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Brancucci Martinez-Anido, C.; Hodge, B. M.

    2014-09-01

    This report presents a new renewable integration study that aims to assess the potential for adding distributed wind to the current power system with minimal or no upgrades to the distribution or transmission electricity systems. It investigates the impacts of integrating large amounts of utility-scale distributed wind power on bulk system operations by performing a case study on the power system of the Independent System Operator-New England (ISO-NE).

  10. Game Changing Usage of High-Voltage Power Transmission Systems as Extremely Large Antennas for Space Physical and Geophysical Remote Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Geomagnetic storms drive geomagnetically induced currents (GIC) in high-voltage power transmission systems worldwide. GIC distribution in the transmission system is...

  11. Investigate the Performance of LG 00 Mode in Cost Effective Hybrid Radio over Multimode Transmission System

    Directory of Open Access Journals (Sweden)

    Pardeep Kaur

    2014-05-01

    Full Text Available Radio over fiber (RoF technology composed for apprehension of future high performance integrated networks and future broadband networks. Multimode fiber links can offer a convenient approach for low cost and short Radio over Fiber (RoF systems. This work is based on the cost effective radio over multimode transmission system (Ro-MMF for long reach transmission. Error free transmission of 10 Gbps data with 10 GHz radio signal over multimode fiber link successfully demonstrated over 40 km. furthermore, The results are represented for Ro-MMF system by using LG (Laguerre-Gaussian 00 mode. The Performance of LG 00 mode in terms of SNR and Eye diagram investigated in proposed system.

  12. Harmonics in Offshore Wind Power Plants Employing Power Electronic Devices in the Transmission System

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm

    of wind power. The onshore as well as offshore wind power plants (OWPPs) therefore have to meet the same stringent requirement as the conventional power plants. This can be accommodated by employment of flexible alternating current transmission system (FACTS) devices, such as the static compensator...... gives rise to a number of challenges to the wind power industry with regard to construction, installation as well as transmission of the generated energy. The STATCOM and the voltage-sourced converter high-voltage direct current (VSC-HVDC) are attractive solutions for grid connection of remotely located...... OWPPs. The new system configuration requires in-depth knowledge of all relevant technical aspects, including e.g. the involved control systems performance and robustness for all possible operating conditions. The transmission system operator might impose new control requirements when the VSC...

  13. The Effects of Crack on the Transmission Matrix of Rotor Systems

    Directory of Open Access Journals (Sweden)

    Z.K. Peng

    2011-01-01

    Full Text Available The dynamic behavior of rotor containing crack is a subject of particular interest and has been extensively investigated by researchers. The effects of crack on the natural frequencies and modal shapes and motion orbits of rotor systems have already been well explored by researchers. In the present study, the infl uence of crack on the transmission matrices of the rotor systems is investigated by using the FEM (finite element method analysis and the HBM (harmonic balance method technique. It is for the first time revealed that there are differences between the transmission matrices for the fundamental frequency components and the transmission matrices for the super-harmonic components, and the differences are mainly determined by the crack location. The results are validated by numerical experiments where the system responses of a rotor system are obtained using Runge-Kutta method. The results are of significance for the development of effective crack detection methods in practice.

  14. Nonlinear phase noise mitigation in phase-sensitive amplified transmission systems.

    Science.gov (United States)

    Olsson, Samuel L I; Karlsson, Magnus; Andrekson, Peter A

    2015-05-04

    We investigate the impact of in-line amplifier noise in transmission systems amplified by two-mode phase-sensitive amplifiers (PSAs) and present the first experimental demonstration of nonlinear phase noise (NLPN) mitigation in a modulation format independent PSA-amplified transmission system. The NLPN mitigation capability is attributed to the correlated noise on the signal and idler waves at the input of the transmission span. We study a single-span system with noise loading in the transmitter but the results are expected to be applicable also in multi-span systems. The experimental investigation is supported by numerical simulations showing excellent agreement with the experiments. In addition to demonstrating NLPN mitigation we also present a record high sensitivity receiver, enabled by low-noise PSA-amplification, requiring only 4.1 photons per bit to obtain a bit error ratio (BER) of 1 × 10(-3) with 10 GBd quadrature phase-shift keying (QPSK) data.

  15. Transmission Congestion and Voltage Profile Management Using TCSC and TCPAR in Deregulated Power System

    Directory of Open Access Journals (Sweden)

    K.Ragini

    2014-10-01

    Full Text Available In present days all our basic needs are relates with electricity. As the population increases, the demand for electricity is also tremendously increases. In the past, the entire electricity industry is under the control of government and also monopolized. But now, the power industry in many countries is moving rapidly from regulated conventional setup to deregulated environment. The transmission congestion is one of the technical problems that particularly appear in the deregulated power system. If congestion is not managed we face the problems of electricity price improvement and security and stability problems. Congestion relief can be handled using FACTS device such as TCSC, TCPAR where transmission capability will be improved. These FACTS devices are optimally placed on transmission system using Sensitivity approach method. The proposed method is carried out on Modified IEEE-14 bus system and IEEE-24 bus system Using Power World Simulator17 software.

  16. Design of aircraft turbine fan drive gear transmission system

    Science.gov (United States)

    Dent, E.; Hirsch, R. A.; Peterson, V. W.

    1970-01-01

    The following basic types of gear reduction concepts were studied as being feasible power train systems for a low-bypass-ratio, single-spool, geared turbofan engine for general aircraft use: (1) single-stage external-internal reduction, (2) gears (offset shafting), (3) multiple compound idler gear system (concentric shafting), and (4) star gear planetary system with internal ring gear final output member (concentric shafting-counterrotation). In addition, studies were made of taking the accessories drive power off both the high-speed and low-speed shafting, using either face gears or spiral bevel gears. Both antifriction and sleeve-type bearings were considered for the external-internal and star-planet reduction concepts.

  17. A Development of a System Enables Character Input and PC Operation via Voice for a Physically Disabled Person with a Speech Impediment

    Science.gov (United States)

    Tanioka, Toshimasa; Egashira, Hiroyuki; Takata, Mayumi; Okazaki, Yasuhisa; Watanabe, Kenzi; Kondo, Hiroki

    We have designed and implemented a PC operation support system for a physically disabled person with a speech impediment via voice. Voice operation is an effective method for a physically disabled person with involuntary movement of the limbs and the head. We have applied a commercial speech recognition engine to develop our system for practical purposes. Adoption of a commercial engine reduces development cost and will contribute to make our system useful to another speech impediment people. We have customized commercial speech recognition engine so that it can recognize the utterance of a person with a speech impediment. We have restricted the words that the recognition engine recognizes and separated a target words from similar words in pronunciation to avoid misrecognition. Huge number of words registered in commercial speech recognition engines cause frequent misrecognition for speech impediments' utterance, because their utterance is not clear and unstable. We have solved this problem by narrowing the choice of input down in a small number and also by registering their ambiguous pronunciations in addition to the original ones. To realize all character inputs and all PC operation with a small number of words, we have designed multiple input modes with categorized dictionaries and have introduced two-step input in each mode except numeral input to enable correct operation with small number of words. The system we have developed is in practical level. The first author of this paper is physically disabled with a speech impediment. He has been able not only character input into PC but also to operate Windows system smoothly by using this system. He uses this system in his daily life. This paper is written by him with this system. At present, the speech recognition is customized to him. It is, however, possible to customize for other users by changing words and registering new pronunciation according to each user's utterance.

  18. Word width reduction system for videosignal processing and transmission

    NARCIS (Netherlands)

    Coenen, A.J.

    1991-01-01

    Abstract of WO 9104611 (A1) System for converting a PCM input signal with uniform noise spectrum, comprising a series of digital words each of K-bits appearing with a predetermined repetition frequency, into a PCM output signal with a non-uniform noise spectrum comprising a series of digital wor

  19. Phase-modulation transmission system for quantum cryptography.

    Science.gov (United States)

    Mérolla, J M; Mazurenko, Y; Goedgebuer, J P; Porte, H; Rhodes, W T

    1999-01-15

    We describe a new method for quantum key distribution that utilizes phase modulation of sidebands of modulation by use of integrated electro-optic modulators at the transmitting and receiving modules. The system is shown to produce constructive or destructive interference with unity visibility, which should allow quantum cryptography to be carried out with high flexibility by use of conventional devices.

  20. Voice Service Support in Mobile Ad Hoc Networks

    CERN Document Server

    Jiang, Hai; Poor, H Vincent; Zhuang, Weihua

    2007-01-01

    Mobile ad hoc networks are expected to support voice traffic. The requirement for small delay and jitter of voice traffic poses a significant challenge for medium access control (MAC) in such networks. User mobility makes it more complex due to the associated dynamic path attenuation. In this paper, a MAC scheme for mobile ad hoc networks supporting voice traffic is proposed. With the aid of a low-power probe prior to DATA transmissions, resource reservation is achieved in a distributed manner, thus leading to small delay and jitter. The proposed scheme can automatically adapt to dynamic path attenuation in a mobile environment. Simulation results demonstrate the effectiveness of the proposed scheme.

  1. Experiment on 60-GHz MMW transmission performance in an optical fiber and wireless system

    Institute of Scientific and Technical Information of China (English)

    Qi Tang; Lin Chen; Jiangnan Xiao; Zizheng Cao

    2011-01-01

    We experimentally investigate the transmission performance of 60-GHz signals over standard single-mode fiber (SSMF) and wireless links at different bit rates.Experimental results show that in a transmission of over 10-km SSMF and 1.3-m wireless link, bit rate reaches up to 5 Gb/s and bit error rate (BER) is leas than 10-4.The main limiting factor in such radio-over-fiber (ROF) systems is intersymbol interferences caused by the so-called walk-off effect when BER is below 10-8.In addition, a transmission of over 20-km SSMF without chromatic dispersion compensation is briefly investigated.For a BER of 10-8, the optical penalty is 2 dB.%@@ We experimentally investigate the transmission performance of 60-GHz signals over standard single-mode fiber (SSMF) and wireless links at different bit rates.Experimental results show that in a transmission of over 10-km SSMF and 1.3-m wireless link, bit rate reaches up to 5 Gb/s and bit error rate (BER) is less than 10-4.The main limiting factor in such radio-over-fiber (ROF) systems is intersymbol interferences caused by the so-called walk-off effect when BER is below 10-8.In addition, a transmission of over 20-km SSMF without chromatic dispersion compensation is briefly investigated.For a BER of 10-s, the optical penalty is 2 dB.

  2. Absence of frequent herpesvirus transmission in a nonhuman primate predator-prey system in the wild.

    Science.gov (United States)

    Murthy, Sripriya; Couacy-Hymann, Emmanuel; Metzger, Sonja; Nowak, Kathrin; De Nys, Helene; Boesch, Christophe; Wittig, Roman; Jarvis, Michael A; Leendertz, Fabian H; Ehlers, Bernhard

    2013-10-01

    Emergence of viruses into the human population by transmission from nonhuman primates (NHPs) represents a serious potential threat to human health that is primarily associated with the increased bushmeat trade. Transmission of RNA viruses across primate species appears to be relatively frequent. In contrast, DNA viruses appear to be largely host specific, suggesting low transmission potential. Herein, we use a primate predator-prey system to study the risk of herpesvirus transmission between different primate species in the wild. The system was comprised of western chimpanzees (Pan troglodytes verus) and their primary (western red colobus, Piliocolobus badius badius) and secondary (black-and-white colobus, Colobus polykomos) prey monkey species. NHP species were frequently observed to be coinfected with multiple beta- and gammaherpesviruses (including new cytomegalo- and rhadinoviruses). However, despite frequent exposure of chimpanzees to blood, organs, and bones of their herpesvirus-infected monkey prey, there was no evidence for cross-species herpesvirus transmission. These findings suggest that interspecies transmission of NHP beta- and gammaherpesviruses is, at most, a rare event in the wild.

  3. Microcontroller - Based System for Electrogastrography Monitoring Through Wireless Transmission

    Science.gov (United States)

    Haddab, S.; Laghrouche, M.

    2009-01-01

    Electrogastrography (EGG) is a non-invasive method for recording the electrical activity of the stomach. This paper presents a system designed for monitoring the EGG physiological variables of a patient outside the hospital environment. The signal acquisition is achieved by means of an ambulatory system carried by the patient and connected to him through skin electrodes. The acquired signal is transmitted via the Bluetooth to a mobile phone where the data are stored into the memory and then transferred via the GSM network to the processing and diagnostic unit in the hospital. EGG is usually contaminated by artefacts and other signals, which are sometimes difficult to remove. We have used a neural network method for motion artefacts removal and biological signal separation.

  4. Frequency Transmission Control of Local Networked Control Systems Approach

    Directory of Open Access Journals (Sweden)

    O. Esquivel-Flores

    2012-08-01

    Full Text Available The use of Network Control Systems has been successful in the industry and therefore has opened several lines ofresearch. Control systems over a communication network include two important considerations, control andscheduling. Co-design strategies are focused on maintaining adequate control performance and maximize the level ofservice. Network scheduling is the main objective to resolve because through a balanced data load is possible tomaintain control performance in a desired level. This article reviews a scheduling strategy based on frequencytransition modeled as a linear subsystem, this control reconfigure on line the sensors’ periods. The case of study isthe control of a prototype helicopter and by numerical simulations it shows the effect of changing the transmissionfrequency.

  5. Grid connection of active stall wind farms using a VSC based DC transmission system

    DEFF Research Database (Denmark)

    Iov, Florin; Sorensen, Paul; Hansen, Anca-Daniela;

    2005-01-01

    are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection...

  6. Cryogenic transmission electron microscopy (cryo-TEM) for studying the morphology of colloidal drug delivery systems

    DEFF Research Database (Denmark)

    Kuntsche, Judith; Horst, Jennifer C; Bunjes, Heike

    2011-01-01

    Cryogenic transmission electron microscopy (cryo-TEM) has evolved into an indispensable tool for the characterization of colloidal drug delivery systems. It can be applied to study the size, shape and internal structure of nanoparticulate carrier systems as well as the overall colloidal composition...

  7. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 kV...

  8. Probe Improvement of Inductive Sensor for Online Health Monitoring of Mechanical Transmission Systems

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Chen, Zhe

    2015-01-01

    Metal debris in lubricating oil contains abundant information regarding the ageing and wear/damage of mechanical transmission systems. The health condition of the lubricated systems can be indicated by the concentration and size of the metal abrasive particles, which may provide very early warnin...

  9. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 k...

  10. Portable light transmission measuring system for preserved corneas

    Science.gov (United States)

    Ventura, Liliane; de Jesus, Gabriel Torres; de Oliveira, Gunter Camilo Dablas; Sousa, Sidney JF

    2005-01-01

    Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively. PMID:16372912

  11. Power line maintenance information system using low-power radio data transmission. Shodenryoku musen denso wo riyoshita sodensen hoshu joho system

    Energy Technology Data Exchange (ETDEWEB)

    Kanemaru, K.; Matsubara, R.; Kaito, J.; Toyota, S. (Hitachi Cable, Ltd., Tokyo (Japan))

    1994-05-20

    Currently in the major power transmission line, a composite fiber optic overhead ground wire (OPGW) is installed, and it is being made the best use as an information transmission line. When the various maintenance informations on the transmission lines can be collected and transmitted by utilizing this OPGW, there will be the benefits that an effective system for the maintenance work of the transmission lines can be constructed, the informations, which could not be obtained by a conventional patrol and tour inspection so far, could be all the time acquired highly accurately and more rapidly. In this report by considering a use of the radio transmission together with OPGW transmission, in order to solve the constraints on an information transmission in a power transmission line maintenance system by utilizing OPGW, the concrete radio transmission systems were proposed about each of interpolation method of the sensor signal transmission method and the OPGW data transmission system. Especially as for the sensor signal system, it was shown that, as a result of the quantitative investigation of a transmission efficiency taking account of the hidden terminal problems, an interpolating data transmission system through a low-power radio combined the slotted transmission timing with the carrier sensed multiple access (CSMA) system was superior. 8 refs., 7 figs., 6 tabs.

  12. A full-duplex CATV/wireless-over-fiber lightwave transmission system.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Ying, Cheng-Ling; Cheng, Chun-Jen; Lin, Che-Yu; Wan, Zhi-Wei; Chen, Jian-Hua

    2015-04-06

    A full-duplex CATV/wireless-over-fiber lightwave transmission system consisting of one broadband light source (BLS), two optical interleavers (ILs), one intensity modulator, and one phase modulator is proposed and experimentally demonstrated. The downstream light is optically promoted from 10Gbps/25GHz microwave (MW) data signal to 10Gbps/100GHz and 10Gbps/50GHz millimeter-wave (MMW) data signals in fiber-wireless convergence, and intensity-modulated with 50-550 MHz CATV signal. For up-link transmission, the downstream light is phase-remodulated with 10Gbps/25GHz MW data signal in fiber-wireless convergence. Over a 40-km single-mode fiber (SMF) and a 10-m radio frequency (RF) wireless transport, bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed to perform well in such full-duplex CATV/wireless-over-fiber lightwave transmission systems. This full-duplex 100-GHz/50-GHz/25-GHz/550-MHz lightwave transmission system is an attractive alternative. This transmission system not only presents its advancement in the integration of fiber backbone and CATV/wireless feeder networks, but also it provides the advantages of a communication channel for higher data rates and bandwidth.

  13. Transmission stability and Raman-induced amplitude dynamics in multichannel soliton-based optical waveguide systems

    Science.gov (United States)

    Peleg, Avner; Nguyen, Quan M.; Tran, Thinh P.

    2016-12-01

    We study transmission stability and dynamics of pulse amplitudes in N-channel soliton-based optical waveguide systems, taking into account second-order dispersion, Kerr nonlinearity, delayed Raman response, and frequency dependent linear gain-loss. We carry out numerical simulations with systems of N coupled nonlinear Schrödinger (NLS) equations and compare the results with the predictions of a simplified predator-prey model for Raman-induced amplitude dynamics. Coupled-NLS simulations for single-fiber transmission with 2 ≤ N ≤ 4 frequency channels show stable oscillatory dynamics of soliton amplitudes at short-to-intermediate distances, in excellent agreement with the predator-prey model's predictions. However, at larger distances, we observe transmission destabilization due to resonant formation of radiative sidebands, which is caused by Kerr nonlinearity. The presence of linear gain-loss in a single fiber leads to a limited increase in transmission stability. Significantly stronger enhancement of transmission stability is achieved in a nonlinear N-waveguide coupler due to efficient suppression of radiative sideband generation by the linear gain-loss. As a result, the distances along which stable Raman-induced dynamics of soliton amplitudes is observed are significantly larger in the waveguide coupler system compared with the single-fiber system.

  14. Voice Savers for Music Teachers

    Science.gov (United States)

    Cookman, Starr

    2012-01-01

    Music teachers are in a class all their own when it comes to voice use. These elite vocal athletes require stamina, strength, and flexibility from their voices day in, day out for hours at a time. Voice rehabilitation clinics and research show that music education ranks high among the professionals most commonly affected by voice problems.…

  15. Neural mechanisms for voice recognition

    NARCIS (Netherlands)

    Andics, A.V.; McQueen, J.M.; Petersson, K.M.; Gal, V.; Rudas, G.; Vidnyanszky, Z.

    2010-01-01

    We investigated neural mechanisms that support voice recognition in a training paradigm with fMRI. The same listeners were trained on different weeks to categorize the mid-regions of voice-morph continua as an individual's voice. Stimuli implicitly defined a voice-acoustics space, and training expli

  16. Reliability worth applied to transmission expansion planning based on ant colony system

    Energy Technology Data Exchange (ETDEWEB)

    Leite da Silva, Armando M.; Rezende, Leandro S. [Institute of Electric Systems and Energy, Federal University of Itajuba, UNIFEI (Brazil); da Fonseca Manso, Luiz A.; de Resende, Leonidas C. [Department of Electrical Engineering, Federal University of Sao Joao del Rei, UFSJ (Brazil)

    2010-12-15

    This paper proposes a new methodology to solve transmission expansion planning (TEP) problems in power system, based on the metaheuristic ant colony optimisation (ACO). The TEP problem includes the search for the least cost solution, bearing in mind investment cost and reliability worth. Reliability worth is considered through the assessment of the interruption costs represented by the index LOLC - loss of load cost. The focus of this work is the development of a tool for the multi-stage planning of transmission systems and how reliability aspects can influence on the decision-making process. The applications of the proposed methodology are illustrated through case studies carried out using a test system and a real sub-transmission network. (author)

  17. A Case Study Of Turkish Transmission System For VoltageDips

    DEFF Research Database (Denmark)

    Inan, E.; Alboyaci, B.; Bak, Claus Leth

    2009-01-01

    Power quality problems usually appear in the form of voltage sags, transients and harmonics. From these three broad categories of power quality problems, voltage dips account the most disturbances experienced by industrial customers. Voltage dips generally refer to instantaneous short...... analysis of voltage dip performance of the whole transmission system, is used to compare with results constructed fault statics from SIMPOW DIPS analysis program real data. SIMPOW DIPS software enables to calculate dip frequency for all busses and lines.......-duration voltage variations. The aim of this paper is to have an idea about voltage dip performance of Turkey Transmission System. Turkey's transmission system has 21 regions. For simulations, 2nd region, which includes Istanbul city's area is heavy loaded, is selected. For purposes of early warning and later...

  18. Network information analysis reveals risk perception transmission in a behaviour-influenza dynamics system.

    Science.gov (United States)

    Liao, C-M; You, S-H; Cheng, Y-H

    2015-01-01

    Influenza poses a significant public health burden worldwide. Understanding how and to what extent people would change their behaviour in response to influenza outbreaks is critical for formulating public health policies. We incorporated the information-theoretic framework into a behaviour-influenza (BI) transmission dynamics system in order to understand the effects of individual behavioural change on influenza epidemics. We showed that information transmission of risk perception played a crucial role in the spread of health-seeking behaviour throughout influenza epidemics. Here a network BI model provides a new approach for understanding the risk perception spread and human behavioural change during disease outbreaks. Our study allows simultaneous consideration of epidemiological, psychological, and social factors as predictors of individual perception rates in behaviour-disease transmission systems. We suggest that a monitoring system with precise information on risk perception should be constructed to effectively promote health behaviours in preparation for emerging disease outbreaks.

  19. Under Water Wireless Control Using Zigbee For Transmissions Systems

    Directory of Open Access Journals (Sweden)

    Sreenivsa Reddy P,

    2014-07-01

    Full Text Available The aim of this project is to develop under water communication system using the zigbee protocol stack. A robot can be defined as a programmable, self-controlled device consisting of electronic, electrical, or mechanical units. An industrial robot is officially defined by as an automatically controlled, reprogrammable, multipurpose, manipulator, programmable in three or more axes. Robots are especially desirable for certain work functions because, unlike humans, they never get tired. They can endure physical conditions that are uncomfortable or even dangerous; they can operate in airless conditions.

  20. HVDC transmission power conversion applications in power systems

    CERN Document Server

    Kim, Chan-Ki; Jang, Gil-Soo; Lim, Seong-Joo; Lee, Seok-Jin

    2009-01-01

    HVDC is a critical solution to several major problems encountered when trying to maintain systemic links and quality in large-scale renewable energy environments. HDVC can resolve a number of issues, including voltage stability of AC power networks, reducing fault current, and optimal management of electric power, ensuring the technology will play an increasingly important role in the electric power industry. To address the pressing need for an up-to-date and comprehensive treatment of the subject, Kim, Sood, Jang, Lim and Lee have collaborated to produce this key text and reference.  Combin

  1. Polarization mode dispersion in optical fiber transmission systems

    Science.gov (United States)

    Cameron, John Charles

    The birefringence of optical fibers causes pulse broadening in fiber-optic communication systems. This phenomenon is known as polarization mode dispersion (PMD). PMD is one of the most important limiting factors for high capacity fiber-optic systems. A number of aspects of PMD are examined in this thesis. In Chapter 2 an expression is derived for the probability density function of the pulse broadening due to first-order PMD. This result is used to obtain an expression for the system limitation due to PMD. The birefringence of optical fibers is commonly simulated with the waveplate model. In Chapter 3 two standard versions of the waveplate model are introduced. In addition, a novel waveplate model is proposed. The characteristics of the three versions of the waveplate model are examined to confirm their suitability for use in subsequent chapters of the thesis. Simulations with the waveplate model are performed in Chapter 4 for three purposes: (1) to determine the impact of chromatic dispersion on the system limitation due to PMD, (2) to examine the effectiveness of three different PMD compensation techniques in the presence of chromatic dispersion, and (3) to examine the interaction of second-order chromatic dispersion with PMD. The simulations in Chapter 4 reveal that it is possible with one compensation technique to have output pulses that are narrower than the input pulses. In Chapter 5, this anomalous pulse narrowing is demonstrated analytically for a simple model of PMD and through experiment. It is also shown that this pulse narrowing can be explained as an interference phenomenon. Chapter 6 presents measurements of PMD and state of polarization on installed optical fibers. The PMD coefficients of 122 fibers are presented and the results are analyzed in terms of the age of the fibers and the type of cabling. Measurements of the time evolution of PMD and state of polarization are presented for fibers installed in both buried and aerial cables. The uncertainty

  2. Adequacy assessment of composite generation and transmission systems incorporating wind energy conversion systems

    Science.gov (United States)

    Gao, Yi

    The development and utilization of wind energy for satisfying electrical demand has received considerable attention in recent years due to its tremendous environmental, social and economic benefits, together with public support and government incentives. Electric power generation from wind energy behaves quite differently from that of conventional sources. The fundamentally different operating characteristics of wind energy facilities therefore affect power system reliability in a different manner than those of conventional systems. The reliability impact of such a highly variable energy source is an important aspect that must be assessed when the wind power penetration is significant. The focus of the research described in this thesis is on the utilization of state sampling Monte Carlo simulation in wind integrated bulk electric system reliability analysis and the application of these concepts in system planning and decision making. Load forecast uncertainty is an important factor in long range planning and system development. This thesis describes two approximate approaches developed to reduce the number of steps in a load duration curve which includes load forecast uncertainty, and to provide reasonably accurate generating and bulk system reliability index predictions. The developed approaches are illustrated by application to two composite test systems. A method of generating correlated random numbers with uniform distributions and a specified correlation coefficient in the state sampling method is proposed and used to conduct adequacy assessment in generating systems and in bulk electric systems containing correlated wind farms in this thesis. The studies described show that it is possible to use the state sampling Monte Carlo simulation technique to quantitatively assess the reliability implications associated with adding wind power to a composite generation and transmission system including the effects of multiple correlated wind sites. This is an important

  3. GPS-Like Phasing Control of the Space Solar Power System Transmission Array

    Science.gov (United States)

    Psiaki, Mark L.

    2003-01-01

    The problem of phasing of the Space Solar Power System's transmission array has been addressed by developing a GPS-like radio navigation system. The goal of this system is to provide power transmission phasing control for each node of the array that causes the power signals to add constructively at the ground reception station. The phasing control system operates in a distributed manner, which makes it practical to implement. A leader node and two radio navigation beacons are used to control the power transmission phasing of multiple follower nodes. The necessary one-way communications to the follower nodes are implemented using the RF beacon signals. The phasing control system uses differential carrier phase relative navigation/timing techniques. A special feature of the system is an integer ambiguity resolution procedure that periodically resolves carrier phase cycle count ambiguities via encoding of pseudo-random number codes on the power transmission signals. The system is capable of achieving phasing accuracies on the order of 3 mm down to 0.4 mm depending on whether the radio navigation beacons operate in the L or C bands.

  4. Transient Stability of the Power System with the Exact Long Transmission Line Model

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: The exact long transmission line model consists of the lump of the series resistance, reactance and shunt capacitance. With the consideration the actual long transmission line model, it causes in the difficulty of deriving the mathematical model. Approach: This study investigates the transient stability of power system with consideration the exact long transmission line model. The concept of two-port network is applied in this study. The generator, transformer and short transmission line are represented by two-port networks. With the combination principles of the series and shunt connection, the mathematical model is achieved in a much simpler way. The proposed method is tested on the sample system and compared on various cases. Results: The first swing of rotor angle curve of the faulted system without the resistance is obviously higher than that of with the resistance whereas the second swing of the faulted system without the resistance is slightly less than that of with the resistance. The critical clearing time of the system with the resistance is better than that of with resistance. Conclusion: It was found from the simulation results that the resistance of the line provides the improvement of the first swing but not for the second swing. It was found from this study that for practical long line, the resistance is very import parameters to determine the critical clearing time of the single machine infinite system whereas shunt capacitance insignificantly affects on the critical clearing time of the single machine infinite bus system.

  5. Design of a digital voice data compression technique for orbiter voice channels

    Science.gov (United States)

    1975-01-01

    Candidate techniques were investigated for digital voice compression to a transmission rate of 8 kbps. Good voice quality, speaker recognition, and robustness in the presence of error bursts were considered. The technique of delayed-decision adaptive predictive coding is described and compared with conventional adaptive predictive coding. Results include a set of experimental simulations recorded on analog tape. The two FM broadcast segments produced show the delayed-decision technique to be virtually undegraded or minimally degraded at .001 and .01 Viterbi decoder bit error rates. Preliminary estimates of the hardware complexity of this technique indicate potential for implementation in space shuttle orbiters.

  6. A Data Transmission Technique for Personal Health Systems

    Directory of Open Access Journals (Sweden)

    Jih-Fu Tu

    2013-01-01

    Full Text Available We used the modular technique to design a personal health data transmitter (PHDT that is composed of the following components: (1 the core is an embedded signal chip, (2 three kinds of transmutation modules such as USB, RF, and UART, (3 an I2C interface is used to acquire the users data, and (4 through Internet it links to the cloud server to store the personal-health data. By the experiment, we find that the modular manner is feasible, stable of functional, integral, and accurate, while it is exploited to design the PHDT. For the experiment, we present each module algorithm to find that our system is very helpful to people.

  7. Transmission of specific groups of bacteria through water distribution system.

    Science.gov (United States)

    Grabińska-Łoniewska, Anna; Wardzyńska, Grazyna; Pajor, Elzbieta; Korsak, Dorota; Boryń, Krystyna

    2007-01-01

    Microbial contamination of a water distribution system was examined. The number and the taxonomy of non-pigmented and pigmented heterotrophic bacteria (HB), number of bacteria (Pseudomonas sp., Enterococcus sp., Campylobacter sp., Yersinia sp., representatives of the Enterobacteriaceae, coagulase-positive staphylococci, and C. pefringens) in the bulk water phase, biomass of zoogloeal aggregates of bacteria, fungi, algae, protozoa and rotifers (ZABFAPR) (separated from the above on 5 microm pore size filters) and in pipe sediments was determined. An increased number of HB occurred at the sampling sites situated as close as 4.2 km to the Water Treatment Plant (WTP), and was especially significant at 10.3 km. It was shown that the main reservoir of hygienically relevant bacteria did not occur in the water phase which is monitored in routine control analyses carried out by the WTP laboratories, but in the ZABFAPR biomass not monitored so far.

  8. Coordinated Direct and Relay Transmission with Interference Cancelation in Wireless Systems

    DEFF Research Database (Denmark)

    Thai, Chan; Popovski, Petar

    2011-01-01

    Two-way relaying schemes in wireless systems obtain throughput gain by utilizing two features (1) jointly serve two communication flows, thus implementing network coding and (2) use of information that is a priori known to cancel interference and obtain the desired signal. Based on these principles......, we propose other schemes that bring throughput gains in wireless cellular systems, where relayed and direct transmissions are carried out in coordinated way. The results show that the coordinated transmission exhibit throughput improvement similar to the two–way relaying schemes....

  9. Higher order capacity statistics of multi-hop transmission systems over Rayleigh fading channels

    KAUST Repository

    Yilmaz, Ferkan

    2012-03-01

    In this paper, we present an exact analytical expression to evaluate the higher order statistics of the channel capacity for amplify and forward (AF) multihop transmission systems operating over Rayleigh fading channels. Furthermore, we present simple and efficient closed-form expression to the higher order moments of the channel capacity of dual hop transmission system with Rayleigh fading channels. In order to analyze the behavior of the higher order capacity statistics and investigate the usefulness of the mathematical analysis, some selected numerical and simulation results are presented. Our results are found to be in perfect agreement. © 2012 IEEE.

  10. Spatiotemporal dynamics of the epidemic transmission in a predator-prey system.

    Science.gov (United States)

    Su, Min; Hui, Cang; Zhang, Yanyu; Li, Zizhen

    2008-11-01

    Epidemic transmission is one of the critical density-dependent mechanisms that affect species viability and dynamics. In a predator-prey system, epidemic transmission can strongly affect the success probability of hunting, especially for social animals. Predators, therefore, will suffer from the positive density-dependence, i.e., Allee effect, due to epidemic transmission in the population. The rate of species contacting the epidemic, especially for those endangered or invasive, has largely increased due to the habitat destruction caused by anthropogenic disturbance. Using ordinary differential equations and cellular automata, we here explored the epidemic transmission in a predator-prey system. Results show that a moderate Allee effect will destabilize the dynamics, but it is not true for the extreme Allee effect (weak or strong). The predator-prey dynamics amazingly stabilize by the extreme Allee effect. Predators suffer the most from the epidemic disease at moderate transmission probability. Counter-intuitively, habitat destruction will benefit the control of the epidemic disease. The demographic stochasticity dramatically influences the spatial distribution of the system. The spatial distribution changes from oil-bubble-like (due to local interaction) to aggregated spatially scattered points (due to local interaction and demographic stochasticity). It indicates the possibility of using human disturbance in habitat as a potential epidemic-control method in conservation.

  11. Protocol Software for a Packet Voice Terminal

    Science.gov (United States)

    1983-11-16

    III satellite. The PVTs with their attached telephone instrument serve as the interface with the voice user. The PVTs prepare speech for transmission...through a packet network by digitizing the speech, preparing speech data packets, and sending speech data messages. The PVT handles the speech coming...TOTALKin. Thes Foori alControle wilno trani speech message s unlTreessin ithas note rcenie s speehdfr ao sufficentpo toefl erAcofitt cdng atei t pfres

  12. Qos and Voice Over IP

    Directory of Open Access Journals (Sweden)

    Adrian GHENCEA

    Full Text Available As Voice over Internet Protocol (VoIP technology matures, companies are increasingly adopting it to cut costs, improve efficiency and enhance customer service. Using the Internet as an existing network for integrating data and telecom systems through intelligent VoIP, a range of benefits results: lower long distance costs, cost cuts in cabling processes and more flexible telephony management. However, as voice over IP services grow in popularity, major threats arise: this rapid growth leads to traffic congestion, security is jeopardizedand the poor quality of calls affects communication. The objective of this article is to present all the elements that can affect voicequality in a VoIP network and to provide methods for solving them. A detailed analysis to minimize the impact of implementation of QoS will be made, and at the end solutions to management strategies will be proposed.

  13. Momentum-independent reflectionless transmission in the non-Hermitian time-reversal symmetric system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.Z.; Song, Z., E-mail: nkquantum@gmail.com

    2013-12-15

    We theoretically study the non-Hermitian systems, the non-Hermiticity of which arises from the unequal hopping amplitude (UHA) dimers. The distinguishing features of these models are that they have full real spectra if all of the eigenvectors are time-reversal (T) symmetric rather than parity-time-reversal (PT) symmetric, and that their Hermitian counterparts are shown to be an experimentally accessible system, which have the same topological structures as that of the original ones but modulated hopping amplitudes within the unbroken region. Under the reflectionless transmission condition, the scattering behavior of momentum-independent reflectionless transmission (RT) can be achieved in the concerned non-Hermitian system. This peculiar feature indicates that, for a certain class of non-Hermitian systems with a balanced combination of the RT dimers, the defects can appear fully invisible to an outside observer. -- Highlights: •We investigate the non-Hermitian system with time reversal symmetry. •The Hermitian counterpart is experimentally accessible system. •The behavior of momentum-independent reflectionless transmission can be achieved. •A balanced combination of reflectionless transmission dimers leads to invisibility. •It paves an alternative way for the design of invisible cloaking devices.

  14. Dominant Voice in Hamlet

    Institute of Scientific and Technical Information of China (English)

    李丹

    2015-01-01

    <正>The Tragedy of Hamlet dramatizes the revenge Prince Hamlet exacts on his uncle Claudius for murdering King Hamlet,Claudius’s brother and Prince Hamlet’s father,and then succeeding to the throne and taking as his wife Gertrude,the old king’s widow and Prince Hamlet’s mother.This paper will discuss something about dominant voice in the play.Dominant voice is the major voice in the country,the society,or the whole world.Those people who have the power or

  15. Wavelet adaptation for automatic voice disorders sorting.

    Science.gov (United States)

    Erfanian Saeedi, Nafise; Almasganj, Farshad

    2013-07-01

    Early diagnosis of voice disorders and abnormalities by means of digital speech processing is a subject of interest for many researchers. Various methods are introduced in the literature, some of which are able to extensively discriminate pathological voices from normal ones. Voice disorders sorting, on the other hand, has received less attention due to the complexity of the problem. Although, previous publications show satisfactory results in classifying one type of disordered voice from normal cases, or two different types of abnormalities from each other, no comprehensive approach for automatic sorting of vocal abnormalities has been offered yet. In this paper, a solution for this problem is suggested. We create a powerful wavelet feature extraction approach, in which, instead of standard wavelets, adaptive wavelets are generated and applied to the voice signals. Orthogonal wavelets are parameterized via lattice structure and then, the optimal parameters are investigated through an iterative process, using the genetic algorithm (GA). GA is guided by the classifier results. Based on the generated wavelet, a wavelet-filterbank is constructed and the voice signals are decomposed to compute eight energy-based features. A support vector machine (SVM) then classifies the signals using the extracted features. Experimental results show that six various types of vocal disorders: paralysis, nodules, polyps, edema, spasmodic dysphonia and keratosis are fully sorted via the proposed method. This could be a successful step toward sorting a larger number of abnormalities associated with the vocal system. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Voice and Speech Quality Perception Assessment and Evaluation

    CERN Document Server

    Jekosch, Ute

    2005-01-01

    Foundations of Voice and Speech Quality Perception starts out with the fundamental question of: "How do listeners perceive voice and speech quality and how can these processes be modeled?" Any quantitative answers require measurements. This is natural for physical quantities but harder to imagine for perceptual measurands. This book approaches the problem by actually identifying major perceptual dimensions of voice and speech quality perception, defining units wherever possible and offering paradigms to position these dimensions into a structural skeleton of perceptual speech and voice quality. The emphasis is placed on voice and speech quality assessment of systems in artificial scenarios. Many scientific fields are involved. This book bridges the gap between two quite diverse fields, engineering and humanities, and establishes the new research area of Voice and Speech Quality Perception.

  17. Comprehensive Benefit Evaluation of the Wind-PV-ES and Transmission Hybrid Power System Consideration of System Functionality and Proportionality

    Directory of Open Access Journals (Sweden)

    Huizheng Ji

    2017-01-01

    Full Text Available In the background of decreasing fossil fuels and increasing environmental pollution, the wind-photovoltaic energy storage and transmission hybrid power system (or called the wind-PV-ES and transmission hybrid system has become a strategic choice to achieve energy sustainability. However, the comprehensive benefit evaluation of such a combined power system is in a relatively blank state in China, which will hinder the reasonable and orderly development of this station. Four parts, the technical performance, economic benefit, ecological impact and social benefit, are considered in this paper, and a multi-angle evaluation index system of the wind-PV-ES and transmission system is designed. The projection pursuit model is used to evaluated system functionality conventionally; relative entropy theory is used to evaluate the system functionality simultaneously; and a comprehensive benefit evaluation model of the technique for order preference by similar to ideal solution (TOPSIS considering both system functionality and proportionality is constructed. Finally, the national demonstration station of the wind-PV-ES-transmission system is taken as an example to testify to the practicability and validity of the evaluation index system and model.

  18. Concept design of the high voltage transmission system for the collider tunnel

    Science.gov (United States)

    Norman, L. S.

    1992-03-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations--such as the Channel Tunnel--demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design.

  19. Coordinated multi-point transmission technique in TDD cellular mobile system

    Institute of Scientific and Technical Information of China (English)

    Sun Shaohui; Gao Qiubin; Rakesh Tamrakar; Wang Yingmin

    2011-01-01

    Coordinated multi-point transmission/reception, CoMP, technique converts the interference signal into the useful information by controlling the interfering signals among adjacent cells. Theoretically, it is a breakthrough from the traditional interference limited non-cooperative single point transmission system, improving link reliability and enhancing the data rate. CoMP is regarded as one of the most essential and effective techniques in eliminating the inter-cell interference, boosting cell edge throughput and overall system throughput. CoMP technique has obvious advantages in TDD (time division duplexing) cellular mobile system; the necessary channel state information for CoMP can be easily obtained through channel reciprocity property in TDD system. CoMP scheme in TDD system and likely problems are analyzed in this paper, and it is shown by system simulations that the significant gain can be achieved.

  20. Power Supply Reliability Assessment in UPFC-installed Transmission System for ATC Enhancement Considering Transient Stability

    Science.gov (United States)

    Masuta, Taisuke; Yokoyama, Akihiko

    With recent development of power electronics technology, power system stability enhancement and optimal power flow control by using Flexible AC Transmission System (FACTS) devices have so far been studied. The FACTS devices to relieve multiple constraints can also make it possible to enhance Available Transfer Capability (ATC) without construction of new transmission lines. The previous research revealed that ATC is expanded by avoiding multiple constraints in OPF using Unified Power Flow Controller (UPFC). For long-term operation of such ATC-expanded power system, it is necessary to evaluate power system reliability. In this paper, the evaluation method of supply reliability for UPFC-installed power system is proposed. Both thermal capacity and transient stability constraints are considered. The effectiveness of the proposed method is shown by numerical examples for IEEJ East10-machine test system.

  1. Experiences Integrating Transmission and Distribution Simulations for DERs with the Integrated Grid Modeling System (IGMS)

    Energy Technology Data Exchange (ETDEWEB)

    Palmintier, Bryan; Hale, Elaine; Hodge, Bri-Mathias; Baker, Kyri; Hansen, Timothy M.

    2016-08-11

    This paper discusses the development of, approaches for, experiences with, and some results from a large-scale, high-performance-computer-based (HPC-based) co-simulation of electric power transmission and distribution systems using the Integrated Grid Modeling System (IGMS). IGMS was developed at the National Renewable Energy Laboratory (NREL) as a novel Independent System Operator (ISO)-to-appliance scale electric power system modeling platform that combines off-the-shelf tools to simultaneously model 100s to 1000s of distribution systems in co-simulation with detailed ISO markets, transmission power flows, and AGC-level reserve deployment. Lessons learned from the co-simulation architecture development are shared, along with a case study that explores the reactive power impacts of PV inverter voltage support on the bulk power system.

  2. Study on Seismic Control of Power Transmission Tower-Line Coupled System under Multicomponent Excitations

    Directory of Open Access Journals (Sweden)

    Li Tian

    2013-01-01

    Full Text Available The seismic control of power transmission tower-line coupled system subjected to multicomponent excitations is studied in this paper. The schematic of tuned mass damper is introduced, and equations of motion of a system with tuned mass damper under multi-component excitations are proposed. Three-dimensional finite tower-line system models are created based on practical engineering in studying the response of this system without and with control. The time domain analysis takes into account geometric nonlinearity due to finite deformation. The optimal design of the transmission tower-line system with tuned mass damper is obtained according to different mass ratio. The effects of wave travel, coherency loss, and different site conditions on the system without and with control are investigated, respectively.

  3. Experimental evaluation of a radio-on-FSO communication system for multiple RF signal transmission

    Science.gov (United States)

    Kazaura, Kamugisha; Dat, Pham; Bekkali, Abdelmoula; Shah, Alam; Suzuki, Toshiji; Wakamori, Kazuhiko; Matsumoto, Mitsuji; Nakamura, Takuya; Takahashi, Koichi; Higashino, Takeshi; Aburakawa, Yuji; Tsukamoto, Katsutoshi; Komaki, Shozo

    2009-02-01

    In this paper we present the design concept plus experimental results and evaluation of a newly developed advanced DWDM Radio-on-Free-Space Optical (RoFSO) communication system capable of simultaneous transmission of multiple RF signals. The RoFSO system is evaluated based on the performance metric parameters defined for the various RF signals comprising of different wireless services including terrestrial digital broadcasting signals, cellular 3GPP W-CDMA signals, IEEE 802.11 WLAN based signals etc being transmitted over the RoFSO link. The performance metric parameters being considered include standard optical received power, CNR and BER characteristics, W-CDMA signal transmission metric parameters like Adjacent Channel Leakage Ratio (ACLR) and Error Vector Magnitude (EVM), modulation error ratio (MER) for digital terrestrial television broadcasting signals as well as spectrum mask and EVM for IEEE 802.11 Wireless LAN signal transmission.

  4. Adaptable System Increasing the Transmission Speed and Reliability in Packet Network by Optimizing Delay

    Directory of Open Access Journals (Sweden)

    Zbynek Kocur

    2014-01-01

    Full Text Available There is a great diversity in the transmission technologies in current data networks. Individual technologies are in most cases incompatible at physical and partially also at the link layer of the reference ISO/OSI model. Network compatibility, as the ability to transmit data, is realizable through the third layer, which is able to guarantee the operation of the different devices across their technological differences. The proposed inverse packet multiplexer addresses increase of the speed and reliability of packet transmission to the third layer, and at the same time it increases the stability of the data communication by the regulation of the delay value during the transmission. This article presents implementation of a communication system and its verification in real conditions. The conclusion compares the strengths and weaknesses of the proposed control system.

  5. An Implementation of Low Cost and Low-power Network Broadcast Data Transmission and Storage System

    Science.gov (United States)

    Yi, Qing-Ming; Shi, Min; He, Yi-Hua

    A connectivity and realization method for the one-to-many remote network data transmission and storage was introduced in this paper. 3D LED display array needs large size data to display a stereo picture. This method was used in 3D LED display array to resolve data secure transmission problem. Combining the Intel 28FJ3A series Flash and Ethernet control chip DM9000A,it applied the Field-Programmable Gate Array (FPGA) and Verilog HDL programming technology to the system, implemented synchronic display and storage of stereograph, and reached 100 Mbps in the network transmission .Testing shows that the system is of low-cost,low-power and high-speed.

  6. Advances in fibers and transmission line technology for long haul submarine systems

    Science.gov (United States)

    Peckham, David W.; Kim, Jinkee; Sun, Yi; Lingle, Robert L., Jr.; Levring, Ole

    2007-11-01

    The 7.1-magnitude earthquake on December 26, 2006 in the Strait of Luzon resulted in the failure of several submarine cable systems. Seven of the nine cables that pass through the strait were damaged, disrupting communications to China, Taiwan, Japan, Korea and Singapore. This recent event highlighted the dependence of international communications on submarine fiber optic transmission systems. This paper will review the evolution of optical fiber transmission line technology that has been deployed in the long haul undersea telecommunications network. It will start with a discussion of the chronological evolution of the optical fiber transmission line architecture in section one, then give more detail regarding the technology that is still being deployed today.

  7. Vibration transmission through rolling element bearings. III - Geared rotor system studies

    Science.gov (United States)

    Lim, T. C.; Singh, R.

    1991-01-01

    The bearing matrix formulations proposed by Lim and Singh (1990) are extended to analyze the overall dynamics of a geared rotor system which includes a spur gear pair, shafts, rolling-element bearings, a motor, a load, a casing, and flexible or rigid mounts. For this purpose, discrete vibration models are developed and used to predict vibration transmission through the bearings and to investigate the effects of the bearing, casing, and mount dynamics on the dynamic characteristics of the internal rotating system. Analytical predictions show that the theory is capable of predicting the bearing and mount moment transmissibilities in addition to the force transmissibilities. The predicted flexural vibrations of the casing plate are in good agreement with measurements conducted on an experimental set-up that consisted of a high-precision beam and pinion, and four identical rolling element bearings contained in a flexible casing mounted rigidly on a massive foundation.

  8. A test of a 2 Tesla superconducting transmission line magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring,; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; /Fermilab; Wake, Masayoshi; /KEK, Tsukuba

    2005-09-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized.

  9. Portable voice-service group call system based on ARM-Linux%基于ARM-Linux的便携式语音群呼系统

    Institute of Scientific and Technical Information of China (English)

    钱莹晶; 张仁民

    2014-01-01

    In order to improve office efficiency and realize the intelligent life, the portable voice-service group call system based on the ARM-Linux is designed. This system is composed of ARM processor (S3C2440), GSM module (TC35i) and voice module (UDA1341). The recorded speech is played through the GSM module controlled by AT instruction coming from ARM. Test results show that this system can record speech, set up call numbers, dial playback and display the unsuccessful numbers automatically. The system has the advantages of friendly interface, simple operation and low cost.%为了提高办公的效率和实现人民生活的智能化,研制了一种基于 ARM-Linux 的便携式语音业务群呼系统。系统以 S3C2440为处理器、TC35i 为GSM 模块、UDA1341为语音芯片, ARM 处理器通过 AT 指令控制 GSM 模块将录制好的语音业务进行群呼。测试结果表明,该系统具有录入话音、设置呼叫号码、自动拨号放音和统计未呼叫成功号码等功能,系统操作简单、界面友好、成本低廉。

  10. Hybrid wireless-over-fiber transmission system based on multiple injection-locked FP LDs.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Chu, Chien-An; Ying, Cheng-Ling; Lu, Ting-Chien; Peng, Peng-Chun

    2015-07-27

    A hybrid wireless-over-fiber (WoF) transmission system based on multiple injection-locked Fabry-Perot laser diodes (FP LDs) is proposed and experimentally demonstrated. Unlike the traditional hybrid WoF transmission systems that require multiple distributed feedback (DFB) LDs to support different kinds of services, the proposed system employs multiple injection-locked FP LDs to provide different kinds of applications. Such a hybrid WoF transmission system delivers downstream intensity-modulated 20-GHz microwave (MW)/60-GHz millimeter-wave (MMW)/550-MHz cable television (CATV) signals and upstream phase-remodulated 20-GHz MW signal. Excellent bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed over a 40-km single-mode fiber (SMF) and a 4-m radio frequency (RF) wireless transport. Such a hybrid WoF transmission system has practical applications for fiber-wireless convergence to provide broadband integrated services, including telecommunication, data communication, and CATV services.

  11. Transmission Performance Analysis of Fiber Optical Parametric Amplifiers for WDM System

    Directory of Open Access Journals (Sweden)

    Xiaohong Jiang

    2009-01-01

    Full Text Available A numerical analysis is presented on the long-haul wavelength-division multiplexing (WDM transmission system employing fiber-optic parametric amplifier (FOPA cascades based on one-pump FOPA model with Raman Effect taken into account. The end-to-end equalization scheme is applied to optimize the system features in terms of proper output powers and signal-to-noise ratios (SNRs in all the channels. The numerical results show that—through adjusting the fiber spans along with the number of FOPAs as well as the channel powers at the terminals in a prescribed way—the transmission distance and system performance can be optimized. By comparing the results generated by different lengths of fiber span, we come to the optimal span length to achieve the best transmission performance. Furthermore, we make a comparison among the long-haul WDM transmission systems employing different inline amplifiers, namely, FOPA, erbium-doped fiber amplifier (EDFA, and Fiber Raman Amplifier (FRA. FOPA demonstrates its advantage over the other two in terms of system features.

  12. A method of applying two-pump system in automatic transmissions for energy conservation

    Directory of Open Access Journals (Sweden)

    Peng Dong

    2015-06-01

    Full Text Available In order to improve the hydraulic efficiency, modern automatic transmissions tend to apply electric oil pump in their hydraulic system. The electric oil pump can support the mechanical oil pump for cooling, lubrication, and maintaining the line pressure at low engine speeds. In addition, the start–stop function can be realized by means of the electric oil pump; thus, the fuel consumption can be further reduced. This article proposes a method of applying two-pump system (one electric oil pump and one mechanical oil pump in automatic transmissions based on the forward driving simulation. A mathematical model for calculating the transmission power loss is developed. The power loss transfers to heat which requires oil flow for cooling and lubrication. A leakage model is developed to calculate the leakage of the hydraulic system. In order to satisfy the flow requirement, a flow-based control strategy for the electric oil pump is developed. Simulation results of different driving cycles show that there is a best combination of the size of electric oil pump and the size of mechanical oil pump with respect to the optimal energy conservation. Besides, the two-pump system can also satisfy the requirement of the start–stop function. This research is extremely valuable for the forward design of a two-pump system in automatic transmissions with respect to energy conservation and start–stop function.

  13. Innovation on Energy Power Technology (8)First HVDC Transmission System in Japan

    Science.gov (United States)

    Sampei, Masatoshi

    This paper is an episode concerning the Hokkaido-Honshu HVDC Link that is the first High Voltage DC Current transmission system in Japan. The effort to the commissioning of the first stage of this system is explained. Moreover, it explains the research and development executed to achieve 600MW of this system that is the final stage. In addition, the adoption episode of the frequency control method introduced for Hokkaido-Honshu HVDC Link is explained.

  14. Stimulated Raman Effect in Bi—driectionally Amplified and Transmission WDM Systems

    Institute of Scientific and Technical Information of China (English)

    KanZHANG; AnshiXU

    1997-01-01

    One of the nonlinear effect-SRS effect in bi-directional WDM transmission systems is studied in this paper,Analytical and numerical results are given to show the effect of SRS.Systems with uni-and bi-directional EDFAs(Erbium doped fiber amplifiers0 are also considered.And a new method to deal with SRS effect in bi-directional systems is drawn out.

  15. Comparison of Voice Perceptual Charactheristics between Speech - Language Pathologists', Dysphonic and Normal Voiced Adult's View

    Directory of Open Access Journals (Sweden)

    Seyyedeh Maryam khoddami

    2010-06-01

    Full Text Available Background and Aim: In recent years, several tools for assessment of quality of patient life have been designed especially for dysphonics. Nowadays, we have useful assessments in health system that are refered for numerous clinical decisions. In this way, this investigation compares clinician and patient perception in dysphonic and normal voiced for first time.Methods: This study was carried out on 30 dysphonic and 30 subjects with normal voice. Their age, sex and job were same. In two groups, Consensus Auditory – Perceptual Evaluation of Voice (CAPE-V was used for evaluation of clinician perception and Voice Handicap Index - 30 (VHI-30 for assessment of patient perception. After collecting data, they were analyzed by Mann- witney and Wilcoxon tests.Results: The research revealed that mean of total and each section score of VHI-30 have significant difference between dysphonic and control group (p<0.01. Comparison of total and every parameter score of CAPE-V and speed also indicated significant difference between two groups (p<0.01. Study of reliability shows weak reliability (r=0.34 between clinician and patient perception of voice in dysphonics.Conclusion: Dysphonic patients percept their voice problem different and severe rather than clinicians that shows physical, psychological and social affects of dysphonia. This research confirms that patient – based assessment of voice is necessary to be part of common assessments of dysphonia.

  16. The study about torsional vibration charateristics and its optimization of vehicle transmission system

    Science.gov (United States)

    Huang, Yuxin; Xin, Qinkun; Yin, Huabing

    2010-06-01

    The torsional vibration of vehicle transmission system is heavily concerned with the increase of vehicle speed. The whole powertrain system has to be matched according to the torsional vibration characteristics, especially in developing a new vehicle. The selection of proper elastic coupling has to be made for the torsional vibration match and some frequencies have to be moved out of engine's range . Thus the torsional vibration model of powertrain needs to be built. In the paper a new torsional vibration model is built, which is programmed in the form of a platform. The whole powertrain system torsional vibration model of a vehicle is built firstly with consideration of gear mesh stiffness and engine's excitation in it. The free torsional vibration mode analysis is made and the resonant torques of each lumped inertia in the transmission system are obtained. Secondly the forced vibration of transmission system with the engine's excitation is made and the dynamic torques of each lumped inertias are obtained. Thirdly the process for the torsional vibration analysis is integrated into the optimization process and the selection of elastic coupling for the transmission system is made according the optimization and match results. Fourthly in order to modify the design parameters in the structural design, the sensitivities of inertia and torsional stiffness with reference to eigenvalues are obtained. At last the evaluations of analysis results are made and some suggestions for structural modification for engineers are presented. According to the above study, the conclusion can be made that the new torsional modelling method, the elastic coupling selection method and integration optimization method in the paper are practical and reliabl and these methods play very important roles in torsional vibration analyzing, match and optimization of vehicle transmission system.

  17. Advanced Error-Control Coding Methods Enhance Reliability of Transmission and Storage Data Systems

    Directory of Open Access Journals (Sweden)

    K. Vlcek

    2003-04-01

    Full Text Available Iterative coding systems are currently being proposed and acceptedfor many future systems as next generation wireless transmission andstorage systems. The text gives an overview of the state of the art initerative decoded FEC (Forward Error-Correction error-control systems.Such systems can typically achieve capacity to within a fraction of adB at unprecedented low complexities. Using a single code requires verylong code words, and consequently very complex coding system. One wayaround the problem of achieving very low error probabilities is turbocoding (TC application. A general model of concatenated coding systemis shown - an algorithm of turbo codes is given in this paper.

  18. Lightning location system for power transmission lines; Sodensen rakurai chiten no tanchi system

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, M. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-04-01

    A novel Lightning Location System (LLS) for power transmission lines has been developed. In this system, an optical loop is constituted, wherein a light signal is reflected by an Optical Fiber Composite Ground Wire (OPGW) end, positioned opposite to the incident end, and returns to the incident end. When a lightning lands on an OPGW, the lightning current travels through the steel tower serving as the grounding route and, because the OPGW is a strand of aluminum-clad wires, produces a magnetic field in the OPGW along its longitudinal direction, which causes fluctuations in polarization simultaneously in the light signals traveling, up or down in the opposite directions, through the lightning-struck spot. When the fluctuations are observed at the receiving end, two fluctuations are detected with a certain time difference between the two, and the time difference is the required information because the time difference is equivalent to the time that is twice the time that a light signal requires to travel from the lightning-struck spot to the light-reflecting end. Accordingly, the distance from the lightning-struck spot can be calculated using the observed time difference. In actual observation in a lightning-abundant period of approximately two months and half, fluctuations in polarization were observed 51 times, and there was agreement on the order of second with the LLS lightning detecting time in 43 out of the 51. 5 refs., 3 figs.

  19. A force transmission system based on a tulip-shaped electrostatic clutch for haptic display devices

    Science.gov (United States)

    Sasaki, Hikaru; Shikida, Mitsuhiro; Sato, Kazuo

    2006-12-01

    This paper describes a novel type of force transmission system for haptic display devices. The system consists of an array of end-effecter elements, a force/displacement transmitter and a single actuator producing a large force/displacement. It has tulip-shaped electrostatic clutch devices to distribute the force/displacement from the actuator among the individual end effecters. The specifications of three components were determined to stimulate touched human fingers. The components were fabricated by using micro-electromechanical systems and conventional machining technologies, and finally they were assembled by hand. The performance of the assembled transmission system was experimentally examined and it was confirmed that each projection in the arrayed end effecters could be moved individually. The actuator in a system whose total size was only 3.0 cm × 3.0 cm × 4.0 cm produced a 600 mN force and displaced individual array elements by 18 µm.

  20. Ethnographic Voice Memo Narratives

    DEFF Research Database (Denmark)

    Rasmussen, Mette Apollo; Conradsen, Maria Bosse

    1800-01-01

    -based technique which actively involves actors in producing ethnography-based data concerning their everyday practice. With the help from smartphone technology it is possible to complement ethnography-based research methods when involving the actors and having them create small voice memo narratives. The voice...... memos create insights of actors‟ everyday practice, without the direct presence of a researcher and could be considered a step towards meeting the dilemmas of research in complex fieldwork settings....