WorldWideScience

Sample records for vertical fluted tube

  1. Design and analysis of a 5-MW vertical-fluted-tube condenser for geothermal applications

    Energy Technology Data Exchange (ETDEWEB)

    Llewellyn, G.H.

    1982-03-01

    The design and analysis of an industtial-sized vertical-fluted-tube condenser. The condenser is used to condense superheated isobutane vapor discharged from a power turbine in a geothermal test facility operated for the US Department of Energy. The 5-MW condenser has 1150 coolant tubes in a four-pass configuration with a total heat transfer area of 725 m/sup 2/ (7800 ft/sup 2/). The unit is being tested at the Geothermal Components Test Facility in the Imperial Valley of East Mesa, California. The condenser design is based on previous experimental research work done at the Oak Ridge National Laboratory on condensing refrigerants on a wide variety of single vertical tubes. Condensing film coefficients obtained on the high-performance vertical fluted tubes in condensing refrigerants are as much as seven times greater than those obtained with vertical smooth tubes that have the same diameter and length. The overall heat transfer performance expected from the fluted tube condenser is four to five times the heat transfer obtained from the identical units employing smooth tubes. Fluted tube condensers also have other direct applications in the Ocean Thermal Energy Conversion (OTEC) program in condensing ammonia, in the petroleum industry in condensing light hydrocarbons, and in the air conditioning and refrigeration industry in condensing fluorocarbon vapors.

  2. Property analysis into the formation of liquid falling thin film on a single channel of a vertical twisted and fluted tube

    Science.gov (United States)

    Yao, Wenlong; Li, Yan; Mei, Ning

    2017-09-01

    In this paper, the influence of helix angle and other parameters to the formation behaviours of liquid falling film on the surface of a helix channel in the case of a vertical fluted tube are investigated. A single-component liquid is considered and the theoretical model is set up to simulate the behaviours of the falling film on the surface of fluted helix tube. The effect of the inclined angle, the Weber number and the channel geometry of the tube axis to the gravity on the formation of the liquid falling film are analysed. By study the film profile, a conclusion is drawn the surface tension drives the fluid into the grooves, thus the film is thinned on the crests of the fluids.

  3. Fluting Modes in Transversely Nonuniform Solar Flux Tubes

    Science.gov (United States)

    Soler, Roberto

    2017-12-01

    Magnetohydrodynamic waves of different types are frequently observed in magnetic flux tubes of the solar atmosphere and are often modeled using simple models. In the standard flux tube model made of a straight uniform tube with an abrupt boundary, transverse wave modes are classified according to their azimuthal wavenumber, m. Sausage (m = 0) and kink (m = 1) modes produce pulsations of the cross section and transverse oscillations of tube axis, respectively. Both sausage and kink modes have been observed in the solar atmosphere. Fluting (m≥slant 2) modes produce perturbations that are essentially confined around the boundary of the tube, I.e., they have a strong surface-like character. Unlike sausage and kink modes, the detection of fluting modes remains elusive. Here we show that the inclusion of transverse inhomogeneity in the flux tube model dramatically affects the properties of fluting modes. Even in a thin tube, kink and fluting modes are no longer degenerate in frequency when the tube has a smooth boundary. In addition, fluting modes become heavily damped by resonant absorption in a timescale shorter than the oscillation period. The perturbations loose their global shape and their distinctive surface-like appearance. As a consequence of that, we argue that nonuniform flux tubes with smooth boundaries may not be able to support fluting-like perturbations as coherent, global modes.

  4. Experimental Study on the Flow and Heat Transfer Characteristics of TiO2-Water Nanofluids in a Spirally Fluted Tube

    Science.gov (United States)

    Qi, Cong; Li, Chunyang; Wang, Guiqing

    2017-09-01

    The flow and heat transfer characteristics of TiO2-water nanofluids with different nanoparticle mass fractions in a spirally fluted tube and a smooth tube are experimentally investigated at different Reynolds numbers. The effects of pH values and doses of dispersant agent on the stability of TiO2-water nanofluids are discussed. The effects of nanoparticle mass fractions and Reynolds numbers on Nusselt numbers and frictional resistance coefficients in the spirally fluted tube and the smooth tube are also investigated. It is found that TiO2-water nanofluids in the spirally fluted tube have a larger enhancement than that in the smooth tube. The heat transfer enhancement and the increase in frictional resistance coefficients of TiO2-water nanofluids in the spirally fluted tube and the smooth tube for laminar flow and turbulent flow are compared. It is found that there are a larger increase in heat transfer and a smaller increase in frictional resistance coefficients for turbulent flow than that for laminar flow of TiO2-water nanofluids in the spirally fluted tube. The comprehensive evaluations for the thermo-hydraulic performance of TiO2-water nanofluids in the smooth tube and spirally fluted tube are also discussed.

  5. CFD investigation of flow and heat transfer of nanofluids in isoflux spirally fluted tubes

    KAUST Repository

    Salama, Amgad

    2012-01-01

    In this work, the problem of flow and heat transfer of nanofluids in spirally fluted tubes is investigated numerically using the CFD code Fluent. The tube investigated in this work is characterized by the existence of helical ridging which is usually obtained by embossing a smooth tube. A tube of diameter of 15 mm, 1.5 mm groove depth and a single helix with pitch of 64 mm is chosen for simulation. This geometry has been chosen for simulation because it has been investigated experimentally for pure fluids and would, therefore, provide a verification framework with our CFD model. The result of our CFD investigation compares very well with the experimental work conducted on this tube geometry. Interesting patterns are highlighted and investigated including the existence of flow swirl as a result of the existence of the spirally enhanced ridges. This swirl flow enhances heat transfer characteristics of this system as reported in the literatures. This study also shows that further enhancement is achieved if small amount of nanoparticles are introduced to the fluid. These nanoparticles (metallic-based nanoparticles) when introduced to the fluid enhances its heat transfer characteristics.

  6. Premixed flame propagation in vertical tubes

    CERN Document Server

    Kazakov, Kirill A

    2015-01-01

    Analytical treatment of premixed flame propagation in vertical tubes with smooth walls is given. Using the on-shell flame description, equations describing quasi-steady flame with a small but finite front thickness are obtained and solved numerically. It is found that near the limits of inflammability, solutions describing upward flame propagation come in pairs having close propagation speeds, and that the effect of gravity is to reverse the burnt gas velocity profile generated by the flame. On the basis of these results, a theory of partial flame propagation driven by the gravitational field is developed. A complete explanation is given of the intricate observed behavior of limit flames, including dependence of the inflammability range on the size of the combustion domain, the large distances of partial flame propagation, and the progression of flame extinction. The role of the finite front-thickness effects is discussed in detail. Also, various mechanisms governing flame acceleration in smooth tubes are ide...

  7. CONDENSATION OF WATER VAPOR IN A VERTICAL TUBE CONDENSER

    Directory of Open Access Journals (Sweden)

    Jan Havlík

    2015-10-01

    Full Text Available This paper presents an analysis of heat transfer in the process of condensation of water vapor in a vertical shell-and-tube condenser. We analyze the use of the Nusselt model for calculating the condensation heat transfer coefficient (HTC inside a vertical tube and the Kern, Bell-Delaware and Stream-flow analysis methods for calculating the shell-side HTC from tubes to cooling water. These methods are experimentally verified for a specific condenser of waste process vapor containing air. The operating conditions of the condenser may be different from the assumptions adopted in the basic Nusselt theory. Modifications to the Nusselt condensation model are theoretically analyzed.

  8. Flute Choir Fundamentals

    Science.gov (United States)

    Chappell, Jon

    2007-01-01

    The flute is one of the more accessible instruments for beginners and is a popular choice for many elementary and middle school students. It is relatively easy to create a decent, usable sound with a flute, and it is more portable than most instruments. While starting a flute choir has a lot of benefits, arranging a band has a lot of challenges.…

  9. Simplified numerical study of evaporation processes inside vertical tubes

    Science.gov (United States)

    Ocłoń, Paweł; Nowak, Marzena; Łopata, Stanisław

    2014-04-01

    The paper presents a simplified numerical model of evaporation processes inside vertical tubes. In this model only the temperature fields in the fluid domain (the liquid or two-phase mixture) and solid domain (a tube wall) are determined. Therefore its performance and efficiency is high. The analytical formulas, which allow calculating the pressure drop and the distribution of heat transfer coefficient along the tube length, are used in this model. The energy equation for the fluid domain is solved with the Control Volume Method and for the solid domain with the Finite Element Method in order to determine the temperature field for the fluid and solid domains.

  10. Numerical simulation of water evaporation inside vertical circular tubes

    Science.gov (United States)

    Ocłoń, Paweł; Nowak, Marzena; Majewski, Karol

    2013-10-01

    In this paper the results of simplified numerical analysis of water evaporation in vertical circular tubes are presented. The heat transfer in fluid domain (water or wet steam) and solid domain (tube wall) is analyzed. For the fluid domain the temperature field is calculated solving energy equation using the Control Volume Method and for the solid domain using the Finite Element Method. The heat transfer between fluid and solid domains is conjugated using the value of heat transfer coefficient from evaporating liquid to the tube wall. It is determined using the analytical Steiner-Taborek correlation. The pressure changes in fluid are computed using Friedel model.

  11. Use of Extended Flute Techniques in Flute Education in Turkey

    Science.gov (United States)

    Sakin, Ajda Senol

    2018-01-01

    Extended flute techniques, which are frequently found in contemporary flute literature, carry the flute to a different dimension, pushing the boundaries of composers and performers. Although the number of pieces containing these techniques in the world has increased rapidly, along with Turkish flute repertoire, written Turkish sources about…

  12. Rotating optical tubes for vertical transport of atoms

    Science.gov (United States)

    Al Rsheed, Anwar; Lyras, Andreas; Aldossary, Omar M.; Lembessis, Vassilis E.

    2016-12-01

    The classical dynamics of a cold atom trapped inside a vertical rotating helical optical tube (HOT) is investigated by taking also into account the gravitational field. The resulting equations of motion are solved numerically. The rotation of the HOT induces a vertical motion for an atom initially at rest. The motion is a result of the action of two inertial forces, namely, the centrifugal force and the Coriolis force. Both inertial forces force the atom to rotate in a direction opposite to that of the angular velocity of the HOT. The frequency and the turning points of the atom's global oscillation can be controlled by the value and the direction of the angular velocity of the HOT. However, at large values of the angular velocity of the HOT the atom can escape from the global oscillation and be transported along the axis of the HOT. In this case, the rotating HOT operates as an optical Archimedes' screw for atoms.

  13. Improvising on an Indian Flute.

    Science.gov (United States)

    Giles, Martha Mead

    1984-01-01

    The Indian flute can be used by teachers to supplement classroom study of Indian culture. Indians used it as a personal instrument. Describes how an Indian flute can be made, and suggests improvising bird calls and melodies on it. (CS)

  14. Stress distribution in maxillary first molar periodontium using straight pull headgear with vertical and horizontal tubes: A finite element analysis

    Directory of Open Access Journals (Sweden)

    Masood Feizbakhsh

    2017-01-01

    Conclusion: Based on the results, when force applied to the straight pull headgear with a vertical tube, Von Mises stress was reduced significantly in comparison with the horizontal tube. Therefore, to correct the mesiolingual movement of the maxillary first molar, vertical headgear tube is recommended.

  15. Inverse Doppler Effects in Flute

    CERN Document Server

    Zhao, Xiao P; Liu, Song; Shen, Fang L; Li, Lin L; Luo, Chun R

    2015-01-01

    Here we report the observation of the inverse Doppler effects in a flute. It is experimentally verified that, when there is a relative movement between the source and the observer, the inverse Doppler effect could be detected for all seven pitches of a musical scale produced by a flute. Higher tone is associated with a greater shift in frequency. The effect of the inverse frequency shift may provide new insights into why the flute, with its euphonious tone, has been popular for thousands of years in Asia and Europe.

  16. A simplified mathematical model of vertical U-tube steam generator in MATLAB environment

    Science.gov (United States)

    Gerova, Gergana; Pasheva, Vesela

    2017-12-01

    The paper presents a vertical U-tube steam generator mathematical model which is developed in MATLAB environment. In the model is used single phase or humongous fluid and are made some simplifications in order to save computational time. After the model was build several numerical simulations were conducted. The changes of some main parameter values like primary water temperature, metal tube temperature, steam generator pressure, and so on are presented in graphs and tables.

  17. Lateral and vertical thermal diffusivities in a dense fluidized bed with tubes bundle

    Energy Technology Data Exchange (ETDEWEB)

    Collantes, M.A.; Martin, G.; Le Gal, J.H. [Institut Francais du Petrole (IFP), 92 - Rueil-Malmaison (France)

    1995-07-01

    Dense fluidized beds are acknowledge as homogeneous systems from both temperature and composition aspects. However, some situation such as very large units or fluidized beds with tubes bundle lead to thermal gradients within the bed. These thermal gradients are due to solids motion limitation and may have detrimental effects on the process. This paper relates investigations aiming an determining lateral and vertical thermal diffusivities in a dense fluidized bed with an without a tubes bundle. These investigations have been carried out with an experimental setup of significant size (bed size = 0.6 x 1.1 x 1.3) and with small particles (less 500 microns) so as to fill some gaps of the literature. Thermal diffusivities have been deduced from temperature gradients measured between a hot wall and a cold wall in a perpendicular fluidized bed and by applying a conventional 2-D conduction model. Lateral thermal conductivities as well as vertical thermal conductivities increase with the gas velocity and the height of the bed, and when the particle size decreases. Immersing a vertical tube bundle into the fluidized bed leads to a significant reduction of the lateral thermal diffusivity, while there is no effect on the vertical thermal diffusivity. Correlations have been drawn from the experimental results. They would have to be applied for calculation of any system running at gas velocity ranging from 0.05 to 0.3 m/s and with particle size between 50 and 300 microns. (authors). 14 refs., 14 figs., 2 tabs.

  18. "Pit Craters", lava tubes, and open vertical volcanic conduits in Hawaii: a problem in terminology

    Directory of Open Access Journals (Sweden)

    William R. Halliday

    1998-01-01

    Full Text Available Almost from the 1849 publication of the term pit crater, volcanologists have disagreed about the parameters differentiating these features from other vertical volcanic structures. Kaluaiki is a jameo giving entry to Thurston Lava Tube in Hawaii Volcanoes National Park. Long-standing misidentification of it as a pit crater is an example of misunderstandings arising from the lack of a clear definition of pit crater. In general, pit craters are unrelated to lava tube caves genetically, but two special cases are discussed. One probably is genetically related to a rift tube deep below the surface; the other is a complex of a small pit crater with a partial rim of accreted plates plus an ordinary-seeming lava tube cave. The term pit crater should be redefined in such a way that it excludes collapses or subsidences related to ordinary superficial lava tubes and open vertical volcanic conduits. Otherwise, a non-definition like that currently listed for agglomerate may be appropriate.

  19. Acoustic Resonance in Cylindrical Tubes with Side Branches

    Science.gov (United States)

    2013-05-01

    branches and tubes that change diameter. 4. Musical Instrument Design A flute is essentially a hollow tube with a way at one end to modulate the...an integer (1,2,3,…). 12 Figure 5. Tube with no holes. The addition of a side branch effectively changes the length of the tube, so in a flute

  20. Experimental investigation of MHD heat transfer in a vertical round tube affected by transverse magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Melnikov, I.A., E-mail: corpuskula@gmail.com; Sviridov, E.V.; Sviridov, V.G.; Razuvanov, N.G.

    2016-11-15

    Highlights: • Local and averaged heat transfer coefficient are measured. • Free convection influence on MHD-flow is investigated. • The region with the free convection effect of MHD-heat transfer is found. • Temperature low-frequency fluctuations of abnormally high amplitude are detected. • Analysis of the MHD-heat transfer experimental data is performed. - Abstract: The article is devoted to the results of experimental investigation of heat transfer for a downward mercury flow in a vertical round tube in the presence of a transverse magnetic with non-uniform heat flux along the tube circumference.

  1. Experimental study of single taylor bubbles rising in stagnant liquid mixtures inside of vertical tubes

    Energy Technology Data Exchange (ETDEWEB)

    Azevedo, Marcos B. de; Faccini, Jose L.H. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Su, Jian, E-mail: sujian@lasme.coppe.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (PEN/COPPE), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2015-07-01

    The present work reports an experimental study of single Taylor bubbles rising in vertical tubes filled with water-glycerin mixtures by using the pulse-echo ultrasonic technique. A 2m long acrylic tube with inner diameter of 24 mm was used in the experiments. Initially, the tube was sealed at the ends and filled partially with the liquid mixtures to leave an air pocket of length L{sub 0} at the top end. A Taylor bubble was formed by the inversion of the tube. The rising bubbles were detected by ultrasonic transducers located at the upper part of the tube. The velocity, the length and the pro le of the bubbles and the thickness of the liquid lm around them were obtained from the ultrasonic signals processing. The liquid lm thickness in the vertical tube was also determined by a graphic method that relates the bubble length L{sub b} with the initial length of the air pocket L{sub 0}. It was observed that the bubble velocity decreased with increasing viscosity, while the lm thickness increased. It was shown that the liquid lm thickness determined by the graphic method fitted well the higher viscosities data, but overestimated the lower viscosities data. Additionally, the results indicated that some correlations developed to estimate the thickness of liquid films falling down inside/outside of tubes and down a plane surface could be applied to estimate the thickness of liquid films falling around Taylor bubbles in an Inverse Viscosity Number (N{sub f} ) range different to those considered in the literature. (author)

  2. Experimental Investigation of Heat Transfer Coefficient in Vertical Tube Rising Film Evaporator

    OpenAIRE

    Syed Naveed Ul Hasan; Sultan Ali

    2011-01-01

    This paper reports the experimental evaluation of the heat transfer coefficient (U) in a VRF (Vertical Tube Rising Film Evaporator). The aim is to describe the variation of U against different process parameters. Experiments were carried out for laminar flow conditions. The experimental unit is a floor standing tubular framework for a rising film evaporation system. There are many parameters affecting heat transfer coefficient in evaporators, but it was not possible to consider all of them, s...

  3. Stress distribution in maxillary first molar periodontium using straight pull headgear with vertical and horizontal tubes: A finite element analysis.

    Science.gov (United States)

    Feizbakhsh, Masood; Kadkhodaei, Mahmoud; Zandian, Dana; Hosseinpour, Zahra

    2017-01-01

    One of the most effective ways for distal movement of molars to treat Class II malocclusion is using extraoral force through a headgear device. The purpose of this study was the comparison of stress distribution in maxillary first molar periodontium using straight pull headgear in vertical and horizontal tubes through finite element method. Based on the real geometry model, a basic model of the first molar and maxillary bone was obtained using three-dimensional imaging of the skull. After the geometric modeling of periodontium components through CATIA software and the definition of mechanical properties and element classification, a force of 150 g for each headgear was defined in ABAQUS software. Consequently, Von Mises and Principal stresses were evaluated. The statistical analysis was performed using T-paired and Wilcoxon nonparametric tests. Extension of areas with Von Mises and Principal stresses utilizing straight pull headgear with a vertical tube was not different from that of using a horizontal tube, but the numerical value of the Von Mises stress in the vertical tube was significantly reduced ( P 0/05). Based on the results, when force applied to the straight pull headgear with a vertical tube, Von Mises stress was reduced significantly in comparison with the horizontal tube. Therefore, to correct the mesiolingual movement of the maxillary first molar, vertical headgear tube is recommended.

  4. Effect of drag-reducing polymers on Tubing Performance Curve (TPC) in vertical gas-liquid flows

    NARCIS (Netherlands)

    Shoeibi Omrani, P.; Veltin, J.; Turkenburg, D.H.

    2014-01-01

    This paper discusses the effect of drag reducing polymers on the Tubing Performance Curve (TPC) of vertical air-water flows at near atmospheric conditions. The effect of polymer concentration, liquid and gas flow rates on the pressure drop curve (Tubing Performance Curve) was investigated

  5. Clinic (Flute Hacks) for Flute Day of the Youth Orchestras of Central Virginia.

    OpenAIRE

    Crone, EL

    2016-01-01

    Invited guest artist for the Flute Day of the Youth Orchestras of Central Virginia. Flute Hacks, Improve Quality of Tone and Embouchure Flexibility clinic for high school area flutists. Supported by Yamaha Corporation.

  6. Mathematical simulation of lithium bromide solution laminar falling film evaporation in vertical tube

    Science.gov (United States)

    Shi, Chengming; Wang, Yang; Hu, Huili; Yang, Ying

    2010-06-01

    For utilization of the residual heat of flue gas to drive the absorption chillers, a lithium-bromide falling film in vertical tube type generator is presented. A mathematical model was developed to simulate the heat and mass coupled problem of laminar falling film evaporation in vertical tube. In the model, the factor of mass transfer was taken into account in heat transfer performance calculation. The temperature and concentration fields were calculated. Some tests were conducted for the factors such as Re number, heating flux, the inlet concentration and operating pressure which can affect the heat and mass transfer performance in laminar falling film evaporation. The heat transfer performance is enhanced with the increasing of heat flux. An increasing inlet concentration can weaken the heat transfer performance. The operating pressure hardly affects on heat and mass transfer. The bigger inlet Re number means weaker heat transfer effects and stronger mass transfer. The mass transfer obviously restrains the heat transfer in the falling film solution. The relation between dimensionless heat transfer coefficient and the inlet Re number is obtained.

  7. Condensation of the air-steam mixture in a vertical tube condenser

    Directory of Open Access Journals (Sweden)

    Havlík Jan

    2016-01-01

    Full Text Available This paper deals with the condensation of water vapour in the presence of non-condensable air. Experimental and theoretical solutions of this problem are presented here. A heat exchanger for the condensation of industrial waste steam containing infiltrated air was designed. The condenser consists of a bundle of vertical tubes in which the steam condenses as it flows downwards with cooling water flowing outside the tubes in the opposite direction. Experiments with pure steam and with mixtures of steam with added air were carried out to find the dependence of the condensation heat transfer coefficient (HTC on the air concentration in the steam mixture. The experimental results were compared with the theoretical formulas describing the cases. The theoretical determination of the HTC is based on the Nusselt model of steam condensation on a vertical wall, where the analogy of heat and mass transfer is used to take into account the behaviour of air in a steam mixture during the condensation process. The resulting dependencies obtained from the experiments and obtained from the theoretical model have similar results. The significant decrease in the condensation HTC, which begins at very low air concentrations in a steam mixture, was confirmed.

  8. Effects of aggregation on the flow properties of red blood cell suspensions in narrow vertical tubes.

    Science.gov (United States)

    Murata, T; Secomb, T W

    1989-01-01

    The flow properties of aggregating red cell suspensions flowing at low rates through vertical tubes with diameters from 30 microns to 150 microns are analyzed using a theoretical model. Unidirectional flow is assumed, and the distributions of velocity and red cell concentration are assumed to be axisymmetric. A three-layer approximation is used for the distribution of red cells, with a cylindrical central core of aggregated red cells moving with uniform velocity, a cell-free marginal layer near the tube wall, and an annular region located between the core and the marginal layer containing suspended non-aggregating red cells. This suspension is assumed to behave approximately as a Newtonian fluid whose viscosity increases exponentially with red cell concentration. Physical arguments concerning the mechanics of red cell attachment to, and detachment from the aggregated core lead to a kinetic equation for core formation. From this kinetic equation and the equation for conservation of red cell volume flux, a relationship between core radius and pressure gradient is obtained. Then the relative viscosity is calculated as a function of pseudo-shear rate. At low flow rates, it is shown that the relative viscosity decreases with decreasing flow and that the dependence of relative viscosity on shear rates is more pronounced in larger tubes. It is also found that the relative viscosity decreases with increasing aggregation tendency of suspension. These theoretical predictions are in good qualitative and quantitative agreement with experimental results.

  9. Dynamic wetting of a liquid film in a vertical hydrophobic tube

    Science.gov (United States)

    Pigeonneau, Franck; Hayoun, Pascaline; Barthel, Etienne; Lequeux, Francois; Verneuil, Emilie; Letailleur, Alban; Teisseire, Jeremie; Saint-Gobain Recherche Collaboration; Espci-Physico-Chimie Des Polymeres Et Milieux Disperses Collaboration; Surface Du Verre Et Interfaces Collaboration

    2016-11-01

    The drop of a liquid plug through a tube occurs for instance in vending machine. In such a system, the fouling is linked to the creation of the liquid film at the rear of the liquid plug. Consequently, the conditions leading to the film creation are important to know. We study numerically the dynamic wetting transition of a liquid plug undergoing gravity on hydrophobic surface in a vertical tube. Using a lubrication theory, the liquid film thickness obeys the mass conservation equation with a volume flow rate depending on the relative motion of the tube, capillary and gravity forces. An ad hoc friction at the triple line is used to take into account the wetting dynamics. The lubrication equation is solved using a finite difference technique in space and a time integrator for stiff system with an adaptive time step. The numerical results are compared to experimental data. The complex film morphology due to the transients and the critical slowing down at the dynamic transition are reproduced. However, several experimental features are not predicted numerically especially the width of the transition. Our preliminary calculations suggest that the dispersion relation of the liquid film mode can explain the discrepancy.

  10. Creating and Maintaining a Good Flute Embouchure

    Science.gov (United States)

    Criswell, Chad

    2009-01-01

    Learning to produce a good tone on the flute is easy for some people and incredibly difficult for others. Not every flute student will be successful, but the suggestions offered in this article may make the difference between a positive musical experience and one that turns the student off to playing an instrument forever. Claire-Anne Williams,…

  11. Flute Physics from a Flutist's Perspective

    Science.gov (United States)

    Boysen, Erika; Ruiz, Michael J.

    2017-01-01

    The basic physics of the flute is presented from the perspective of a professional flutist. The flutist can control loudness, pitch and to some extent timbre. Oscilloscope images are provided to compare changes in these three fundamental sound characteristics. Readers can view a video (Ruiz 2017 "Video: The Flute"…

  12. Quality Characteristics of bread made from Wheat and Fluted ...

    African Journals Online (AJOL)

    Bread fortified with fluted pumpkin seed flour was made; the seeds of fluted pumpkin were extracted and processed into raw dried flour. Appropriate quantities of wheat and fluted pumpkin flour (on dry weight basis) were measured and mixed to give the following blends, 90:10, 80:20, 60:40, 50:50, wheat/fluted pumpkin ...

  13. Investigation of boiling heat transfer of binary mixture from vertical tube embedded in porous media

    Science.gov (United States)

    Mo, Hailong; Ma, Tongze; Zhang, Zhengfang

    1996-07-01

    Ethanol-water binary mixtures with 7 different mole fractions of ethanol ranging from 0 to 1 were adopted as testing liquids in the experiment. The vertical heating tube was inserted in porous matrix composed of five well sorted glass beads whose diameters range from 0.5 to 4.3 mm. Due to the effect of composition, the trend of combination of vapor bubbles was reduced, resulting in the increase of peak heat flux of binary mixture. With the increase of ethanol mole fraction, 0.5 mm diameter bead had lower value of peak heat flux, while for pure liquid the critical state is difficult to appear. With given diameter of glass bead, there existed an optimum value of mole fraction of ethanol, which was decreased with the increase of bead diameter. A dimensionless heat transfer coefficient was predicted through the introduction of a dimensionless parameter of porous matrix, which agreed with the experimental results satisfactorily.

  14. Reliability of horizontal and vertical tube shift techniques in the localisation of supernumerary teeth.

    Science.gov (United States)

    Mallineni, S K; Anthonappa, R P; King, N M

    2016-12-01

    To assess the reliability of the vertical tube shift technique (VTST) and horizontal tube shift technique (HTST) for the localisation of unerupted supernumerary teeth (ST) in the anterior region of the maxilla. A convenience sample of 83 patients who attended a major teaching hospital because of unerupted ST was selected. Only non-syndromic patients with ST and who had complete clinical and radiographic and surgical records were included in the study. Ten examiners independently rated the paired set of radiographs for each technique. Chi-square test, paired t test and kappa statistics were employed to assess the intra- and inter-examiner reliability. Paired sets of 1660 radiographs (830 pairs for each technique) were available for the analysis. The overall sensitivity for VTST and HTST was 80.6 and 72.1% respectively, with slight inter-examiner and good intra-examiner reliability. Statistically significant differences were evident between the two localisation techniques (p < 0.05). Localisation of unerupted ST using VTST was more successful than HTST in the anterior region of the maxilla.

  15. An illuminated flute needle for vitreoretinal surgery.

    Science.gov (United States)

    Davison, C N; Rosen, P H

    1994-06-01

    We have developed a simple self-illuminated flute needle for internal drainage of subretinal fluid during three-port vitrectomy. This instrument facilitates visualization and drainage through peripheral retinal breaks.

  16. Study of the motion and deposition of micro particles in a vertical tube containing uniform gas flow

    Science.gov (United States)

    Abolpour, Bahador; Afsahi, M. Mehdi; Soltani Goharrizi, Ataallah; Azizkarimi, Mehdi

    2017-12-01

    In this study, effects of a gaseous jet, formed in a vertical tube containing a uniform gas flow, on the injected micro particles have been investigated. A CFD model has been developed to simulate the particle motion in the tube. This simulation is very close to the experimental data. The results show that, increasing the flow rate of carrier gas or decreasing the flow rate of surrounding gas increases the effect of gaseous jet and also increases trapping rate of the particles by the tube wall. The minimum and maximum residence times of particles approach together with increasing the size of solid particles. Particles larger than 60 μm have a certain and fixed residence time at different flow rates of the carrier or surrounding gas. About 40 μm particle size has minimal trapping by the tube wall at various experimental conditions.

  17. Experimental Investigation of Heat Transfer Coefficient in Vertical Tube Rising Film Evaporator

    Directory of Open Access Journals (Sweden)

    Syed Naveed Ul Hasan

    2011-10-01

    Full Text Available This paper reports the experimental evaluation of the heat transfer coefficient (U in a VRF (Vertical Tube Rising Film Evaporator. The aim is to describe the variation of U against different process parameters. Experiments were carried out for laminar flow conditions. The experimental unit is a floor standing tubular framework for a rising film evaporation system. There are many parameters affecting heat transfer coefficient in evaporators, but it was not possible to consider all of them, so parameters including, Reynolds Number (NRe, Temperature Difference (DT, Feed Temperature (Tf and Re-circulation Ratio (R were investigated while other factors were kept constant. The experimental results obtained showed that heat transfer coefficient increased with the increase in Reynolds number, feed temperature and temperature difference. The increase in re-circulation ratio also increased the heat transfer coefficient but up to the value of 0.85 and after this the heat transfer coefficient started decreasing slowly and then remained almost constant. An experimental correlation has been developed to relate the Nusselt number and the parameters investigated during the research work.

  18. Film stability in a vertical rotating tube with a core-gas flow.

    Science.gov (United States)

    Sarma, G. S. R.; Lu, P. C.; Ostrach, S.

    1971-01-01

    The linear hydrodynamic stability of a thin-liquid layer flowing along the inside wall of a vertical tube rotating about its axis in the presence of a core-gas flow is examined. The stability problem is formulated under the conditions that the liquid film is thin, the density and viscosity ratios of gas to liquid are small and the relative (axial) pressure gradient in the gas is of the same order as gravity. The resulting eigenvalue problem is first solved by a perturbation method appropriate to axisymmetric long-wave disturbances. The damped nature (to within the thin-film and other approximations made) of the nonaxisymmetric and short-wave disturbances is noted. In view of the limitations on a truncated perturbation solution when the disturbance wavenumber is not small, an initial value method using digital computer is presented. Stability characteristics of neutral, growing, and damped modes are presented showing the influences of rotation, surface tension, and the core-gas flow. Energy balance in a neutral mode is also illustrated.

  19. Boiling Heat Transfer and Pressure Drop of a Refrigerant Flowing Vertically Downward in a Small Diameter Tube

    Science.gov (United States)

    Miyata, Kazushi; Mori, Hideo; Ohishi, Katsumi; Tanaka, Hirokazu

    Experiments were performed on boiling heat transfer and pressure drop of a refrigerant R410A flowing vertically downward in a copper smooth tube of 1.0 mm inside diameter for the development of a high-performance heat exchanger using small diameter tubes for air conditioning systems. Local heat transfer coefficients were measured in a range of mass fluxes from 30 to 200 kg/(m2•s), heat fluxes from 1 to 16 kW/m2 and quality from 0.1 to over 1 at evaporation temperature of 10°C. Pressure drops were measured and flow patterns were observed at mass fluxes from 30 to 200 kg/(m2•s) and quality from 0.1 to 0.9. The characteristics of frictional pressure drop, heat transfer coefficient and dryout qualities were clarified by comparing the measurements with the data for the vertically upward flow previously obtained.

  20. Heat Transfer Experiments with Supercritical CO{sub 2} in a Vertical Circular Tube (9.0 mm)

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Tae Ho; Kim, Hwan Yeol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Sim, Woo Gun; Bae, Yoon Yeong [Hannam University, Daejeon (Korea, Republic of)

    2008-10-15

    Heat transfer test facility, SPHINX(Supercritical Pressure Heat transfer Investigation for NeXt generation), has been operated at KAERI for an investigation of the thermal-hydraulic behaviors of supercritical CO{sub 2} at several test sections with a different geometry. The loop uses CO{sub 2} because it has critical pressure and temperature which is much lower than water. Experimental study of heat transfer to supercritical CO{sub 2} in a vertical circular tube with and inner diameter of 9.0mm has been performed. CO{sub 2} flows downward through the vertical circular tube for the simulation of the water rod which may be used for a moderation of the reactor. The heat transfer characteristics were analyzed and compared with the upward flow test results previously performed at the same test section at KAERI.

  1. Stress distribution in maxillary first molar periodontium using straight pull headgear with vertical and horizontal tubes: A finite element analysis

    OpenAIRE

    Feizbakhsh, Masood; Kadkhodaei, Mahmoud; Zandian, Dana; Hosseinpour, Zahra

    2017-01-01

    Background: One of the most effective ways for distal movement of molars to treat Class II malocclusion is using extraoral force through a headgear device. The purpose of this study was the comparison of stress distribution in maxillary first molar periodontium using straight pull headgear in vertical and horizontal tubes through finite element method. Materials and Methods: Based on the real geometry model, a basic model of the first molar and maxillary bone was obtained using three-dimen...

  2. Entropy and the Magic Flute

    Science.gov (United States)

    Morowitz, Harold J.

    1996-10-01

    Harold Morowitz has long been highly regarded both as an eminent scientist and as an accomplished science writer. The essays in The Wine of Life , his first collection, were hailed by C.P. Snow as "some of the wisest, wittiest and best informed I have ever read," and Carl Sagan called them "a delight to read." In later volumes he established a reputation for a wide-ranging intellect, an ability to see unexpected connections and draw striking parallels, and a talent for communicating scientific ideas with optimism and wit. With Entropy and the Magic Flute , Morowitz once again offers an appealing mix of brief reflections on everything from litmus paper to the hippopotamus to the sociology of Palo Alto coffee shops. Many of these pieces are appreciations of scientists that Morowitz holds in high regard, while others focus on health issues, such as America's obsession with cheese toppings. There is also a fascinating piece on the American Type Culture Collection, a zoo or warehouse for microbes that houses some 11,800 strains of bacteria, and over 3,000 specimens of protozoa, algae, plasmids, and oncogenes. Here then are over forty light, graceful essays in which one of our wisest experimental biologists comments on issues of science, technology, society, philosophy, and the arts.

  3. Prediction of friction factor of pure water flowing inside vertical smooth and microfin tubes by using artificial neural networks

    Science.gov (United States)

    Çebi, A.; Akdoğan, E.; Celen, A.; Dalkilic, A. S.

    2017-02-01

    An artificial neural network (ANN) model of friction factor in smooth and microfin tubes under heating, cooling and isothermal conditions was developed in this study. Data used in ANN was taken from a vertically positioned heat exchanger experimental setup. Multi-layered feed-forward neural network with backpropagation algorithm, radial basis function networks and hybrid PSO-neural network algorithm were applied to the database. Inputs were the ratio of cross sectional flow area to hydraulic diameter, experimental condition number depending on isothermal, heating, or cooling conditions and mass flow rate while the friction factor was the output of the constructed system. It was observed that such neural network based system could effectively predict the friction factor values of the flows regardless of their tube types. A dependency analysis to determine the strongest parameter that affected the network and database was also performed and tube geometry was found to be the strongest parameter of all as a result of analysis.

  4. Design concept for the FLUTE control system

    Energy Technology Data Exchange (ETDEWEB)

    Marsching, Sebastian; Huttel, Erhard; Mueller, Anke-Susanne; Naknaimueang, Somprasong; Nasse, Michael J.; Rossmanith, Robert; Schreck, Marco; Schuh, Marcel; Schwarz, Markus [Karlsruhe Institute of Technology, Karlsruhe (Germany)

    2013-07-01

    FLUTE is a linac-based THz-source being constructed at the Karlsruhe Institute of Technology (KIT). One of the goals of the FLUTE project is the generation of femtosecond electron-bunches. In order to study the various effects influencing the final bunch length, data-acquisition and storage systems that allow correlation of parameters on a per-pulse basis are required. We are planning to use an EPICS-based control system that employs special techniques for pulse-synchronous data-acquisition. In this talk we present the current design concept for this system.

  5. Step-Wise Velocity of an Air Bubble Rising in a Vertical Tube Filled with a Liquid Dispersion of Nanoparticles.

    Science.gov (United States)

    Cho, Heon Ki; Nikolov, Alex D; Wasan, Darsh T

    2017-03-21

    The motion of air bubbles in tubes filled with aqueous suspensions of nanoparticles (nanofluids) is of practical interest for bubble jets, lab-on-a-chip, and transporting media. Therefore, the focus of this study is the dynamics of air bubbles rising in a tube in a nanofluid. Many authors experimentally and analytically proposed that the velocity of rising air bubbles is constant for long air bubbles suspended in a vertical tube in common liquids (e.g. an aqueous glycerol solution) when the capillary number is larger than 10-4. For the first time, we report here a systematic study of an air bubble rising in a vertical tube in a nanofluid (e.g. an aqueous silica dioxide nanoparticle suspension, nominal particle size, 19 nm). We varied the bubble length scaled by the diameter of the tubes (L/D), the concentration of the nanofluid (10 and 12.5 v %), and the tube diameter (0.45, 0.47, and 0.50 cm). The presence of the nanoparticles creates a significant change in the bubble velocity compared with the bubble rising in the common liquid with the same bulk viscosity. We observed a novel phenomenon of a step-wise increase in the air bubble rising velocity versus bubble length for small capillary numbers less than 10-7. This step-wise velocity increase versus the bubble length was not observed in a common fluid. The step-wise velocity increase is attributed to the nanoparticle self-layering phenomenon in the film adjacent to the tube wall. To elucidate the role of the nanoparticle film self-layering on the bubble rising velocity, the effect of the capillary number, the tube diameter (e.g. the capillary pressure), and nanofilm viscosity are investigated. We propose a model that takes into consideration the nanoparticle layering in the film confinement to explain the step-wise velocity phenomenon versus the length of the bubble. The oscillatory film interaction energy isotherm is calculated and the Frenkel approach is used to estimate the film viscosity.

  6. A flute syringe for vitreous surgery.

    Science.gov (United States)

    Escoffery, R F; Grand, M G

    1980-11-01

    We have devised a method whereby an inexpensive, disposable tuberculin syringe may be used as a flute syringe with retrograde flushing capability. This syringe is particularly useful in vitreous surgery and alleviates problems that occur with commercially available instruments of this type.

  7. Exchange flows of two immiscible Newtonian liquids in a vertical tube: From falling drops to falling slugs

    Science.gov (United States)

    Varges, P. R.; Fonseca, B. S.; Naccache, M. F.; de Souza Mendes, P. R.

    2017-06-01

    We present an experimental study of buoyancy-driven flows of two immiscible Newtonian liquids in a vertical tube where initially the heavier and more viscous one is placed on the top of the lighter one. Flow visualization was performed using a digital camera, and inversion velocities were determined through image analysis. The influence of the governing parameters on the speed and flow regime was examined for pairs of liquids with small density differences. Two different flow regimes were observed, namely, falling drops and falling slugs. In the first regime, spherical and ellipsoidal drops are obtained, depending on the ratio between the drop and tube diameters. The falling slug regime is a core-annular flow pattern above a critical value of interfacial tension, while no flow is noticed below this critical value. The experimental results are in good agreement with model predictions from the literature. Indeed, the results showed that terminal velocity can be estimated by empirical correlations for falling spheres.

  8. Assessment of RELAP5/MOD3.2 with condensation experiment in the presence of noncondensables in a vertical tube

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Sik; No, Hee Cheon [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-12-31

    The standard RELAP5/MOD3.2 code were assessed with the condensation experiment in the presence of noncondensable gas in a vertical tube of PCCS of CP-1300. There are two wall film condensation models, the default model and the alternative model, in RELAP5/MOD3.2. The experimental apparatus was modeled with the two models, and simulations were performed for several sub-tests to be compared with the experimental results. In overall sense the simulation results showed that the default model of RELAP5/MOD3.2 under-predicts the heat transfer coefficients, while the alternative model over-predicts them throughout the condensing tube. 10 refs., 6 figs. (Author)

  9. Investigation of Transient, Turbulent Natural Convection in Vertical Tubes for Thermal Energy Storage in Supercritical CO2

    Science.gov (United States)

    Baghaei Lakeh, Reza; Lavine, Adrienne S.; Kavehpour, H. Pirouz; Wirz, Richard E.

    2013-11-01

    Heat transfer can be a limiting factor in the operation of thermal energy storage, including sensible heat and latent heat storage systems. Poor heat transfer between the energy storage medium and the container walls impairs the functionality of the thermal storage unit by requiring excessively long times to charge or discharge the system. In this study, the effect of turbulent, unsteady buoyancy-driven flow on heat transfer in vertical storage tubes containing supercritical CO2 as the storage medium is investigated computationally. The heat transfer from a constant-temperature wall to the storage fluid is studied during the charge cycle. The results of this study show that turbulent natural convection dominates the heat transfer mechanism and significantly reduces the required time for charging compared to pure conduction. Changing the L/D ratio of the storage tube has a major impact on the charge time. The charge time shows a decreasing trend with RaL. The non-dimensional model of the problem shows that Nusselt number and non-dimensional mean temperature of the storage fluid in different configurations of the tube is a function Buoyancy-Fourier number defined as of FoL * RaLm* L/D. This study was supported by award No. DE-AR0000140 granted by U.S. Department of Energy under Advanced Research Projects Agency - Energy (ARPA-E) and by award No. 5660021607 granted by Southern California Gas Company.

  10. Boiling Heat Transfer and Pressure Drop of a Refrigerant Flowing Vertically Upward in a Small Diameter Tube

    Science.gov (United States)

    Miyata, Kazushi; Mori, Hideo; Ohishi, Katsumi; Tanaka, Hirokazu

    In the present study, experiments were performed to examine characteristics of flow boiling heat transfer and pressure drop of a refrigerant R410A flowing vertically upward in a copper smooth tube with 1.0 mm inside diameter for the development of a high-performance heat exchanger using small diameter tubes for air conditioning systems. Local heat transfer coefficients were measured in a range of mass fluxes from 30 to 200 kg/(m2•s), heat fluxes from 1 to 16 kW/m2 and qualities from 0.1 to over 1 at evaporation temperature of 10°C, and pressure drops were also measured at mass fluxes of 100 and 200 kg/(m2•s) and qualities from 0.1 to 0.9. Three types of flow pattern were observed in the tube: A slug, a slug-annular and an annular flow. Based on the measurements, the characteristics of frictional pressure drop, heat transfer coefficient and dryout qualities were clarified. The measured pressure drop and heat transfer coefficient were compared with correlations.

  11. 3D Simulation of the Fluted Mixer Element Behavior

    Science.gov (United States)

    Kubik, Pavel; Vlcek, Jiri; Svabik, Jiri; Paseka, Ilja; Zatloukal, Martin

    2009-07-01

    In this work, two different fluted mixing elements have been investigated by 3D FEM analysis. It has been found that open fluted mixing element has lower temperature losses than closed fluted mixer which can be explained by the presence of the layer, which is slowly rotating very close to the barrel in the case of the open fluted mixing element. It also has been found that the shear stress in this isolation polymer melt layer is lower than 20 kPa, which may leads to polymer melt degradation. From the obtained theoretical data, it can be concluded that open fluted mixing element may behave much more differently than the closed fluted mixing element.

  12. Flute physics from a flutist’s perspective

    Science.gov (United States)

    Boysen, Erika; Ruiz, Michael J.

    2017-07-01

    The basic physics of the flute is presented from the perspective of a professional flutist. The flutist can control loudness, pitch and to some extent timbre. Oscilloscope images are provided to compare changes in these three fundamental sound characteristics. Readers can view a video (Ruiz 2017 Video: The Flute http://mjtruiz.com/ped/flute/) where coauthor, flutist Erika Boysen, demonstrates the topics covered in this paper.

  13. 3D simulation of the fluted mixer element behavior

    OpenAIRE

    Kubík, Pavel; Vlček, Jiří; Švábík, Jiří; Paseka, Ilja; Zatloukal, Martin

    2009-01-01

    In this work, two different fluted mixing elements have been investigated by 3D FEM analysis. It has been found that open fluted mixing element has lower temperature losses than closed fluted mixer which can be explained by the presence of the layer, which is slowly rotating very close to the barrel in the case of the open fluted mixing element. It also has been found that the shear stress in this isolation polymer melt layer is lower than 20 kPa, which may leads to polymer melt degradation. ...

  14. Stability of viscous film flow coating the interior of a vertical tube with a porous wall

    Science.gov (United States)

    Liu, Rong; Ding, Zijing

    2017-05-01

    The stability of the gravity-driven flow of a viscous film coating the inside of a tube with a porous wall is studied theoretically. We used Darcy's law to describe the motion of fluids in a porous medium. The Beaver-Joseph condition is used to describe the discontinuity of velocity at the porous-fluid interface. We derived an evolution equation for the film thickness using a long-wave approximation. The effect of velocity slip at the porous wall is identified by a parameter β . We examine the effect of β on the temporal stability, the absolute-convective instability (AI-CI), and the nonlinear evolution of the interface deformation. The results of the temporal stability reveal that the effect of velocity slip at the porous wall is destabilizing. The parameter β plays an important role in determining the AI-CI behavior and the nonlinear evolution of the interface. The presence of the porous wall promotes the absolute instability and the formation of the plug in the tube.

  15. TRACE assessment on local condensation heat transfer in presence of non-condensable gas inside a vertical tube

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Jin; Ahn, Seung Hoon; Kim, Kap; Kim, Hho Jung [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2009-07-01

    TRACE assessment was performed to investigate local condensation heat transfer coefficients in the presence of a noncondensable gas inside a vertical tube. The data obtained from pure steam and steam/nitrogen mixture condensation experiments were compared to study the effects of noncondensable nitrogen gas on the annular film condensation phenomena. The condenser tube had a small inner diameter of 13mm (about 1/2-in.) and this experiment had been performed to prove the effectiveness of the a Passive Residual Heat Removal System (PRHRS) of SMART (System-integrated Modular Advanced ReacTor), which is a small modular integral-type pressurized water reactor that is developed for the dual purposes of seawater desalination and small-scaled power generation. In the case of nitrogen presence, TRACE results show the converged results but the prediction is different from experimental data. The candidate reasons can be focused on several models, such as the film thickness calculation, surface area, and condensation heat transfer correlations, etc. In the case of pure steam condensation case, TRACE results shows large oscillations and do not converge. This should be investigated in detail to identify the reason. Until now, the oscillation in thermal hydraulic parameters results from the film thickness calculation and surface area calculation. For future works, the whole sets of the experiment will be assessed and the improvement of TRACE will be performed.

  16. Gas suspension flows of a moderately dense binary mixture of solid particles in vertical tubes

    Energy Technology Data Exchange (ETDEWEB)

    Zamankhan, P.; Huotari, J. [VTT Energy, Jyvaeskylae (Finland). Combustion and Conversion Lab.

    1996-12-01

    The turbulent, steady, fully-developed flow of a moderately dense (solid volume faction >>0.001) binary mixture of spherical particles in a gaseous carrier is investigated for the case of flow in a vertical riser. The suspended particles are considered to be in turbulent motion, driven by random aerodynamic forces acting between the particle and the gaseous carrier as well as particle-particle interactive forces. A model is constructed based on the combination of the time-averaged after volume-averaged conservation equations of mass, momentum and mechanical energy of the gas phase in the continuum theory and the corresponding equations for the solid particles obtained using the recently developed Enskog theory for dense multi-component mixtures of slightly inelastic spherical particles. The model properly takes into account the contributions of particle-particle collisions, as well as the fluid-dynamic fluctuating forces on individual particles. To demonstrate the validity of this approach, the fully-developed steady-state mean velocity and concentration distributions of a moderately dense binary mixture of solid particles in a turbulent vertical flow calculated by the present model are compared with available experimental measurements. The results provide a qualitative description of the experimentally observed motion of coarse particles in a fast bed of fine solids. (author)

  17. Numerical investigation of MHD heat transfer in a vertical round tube affected by transverse magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Zikanov, Oleg [University of Michigan - Dearborn, MI 48128-1491 (United States); Listratov, Yaroslav [Moscow Power Engineering Institute, 14 Karsnokazarmennaya St., Moscow 111250 (Russian Federation)

    2016-12-15

    Numerical simulations of the flow of a liquid metal in a vertical pipe are performed. The configuration reproduces the test section of the recent experiment . The mean flow is directed downward, a half of the pipe's wall is heated, and a strong horizontal magnetic field perpendicular to the temperature gradient is imposed. The simulations produce results in good agreement with the experiment and lead us to an explanation of the observed phenomenon of anomalous high-amplitude temperature fluctuations. The fluctuations are caused by growth and quasi-periodic breakdown of the pairs of ascending and descending jets related to the elevator-mode thermal convection. Implications for operation of liquid metal blankets with poloidal ducts are discussed.

  18. Ultrasonic pumping of liquids in the two directions of a vertical tube by a vibrating surface

    DEFF Research Database (Denmark)

    Santillan, Arturo Orozco; Cutanda Henriquez, Vicente

    2010-01-01

    It has been reported that it is possible to pump a liquid into the interior of a vertical pipe when its lower end is facing a vibrating plane surface immersed in the liquid. The column of liquid pumped in a thin pipe can be higher than 2 m if the gap between the pipe end and the vibrating...... horizontal surface is very small, around 0.01 mm. In this paper we present experimental results showing that, with a similar set up as the one mentioned above, it is also possible to pump liquids in the opposite direction, from the interior of the pipe through the gap. The general objective of the work has...... been to advance in the understanding of both phenomena. By using the Boundary Element Method, the sound pressure field in the liquid is determined. The velocity field, Lagrangian excess pressure, and sound intensity are obtained from the sound pressure. Experimental results show that the amplitude...

  19. Effect of Resistance Tube Exercises on Kicking Accuracy, Vertical Jump and 40-Yard Technical Test in Competitive Football Players – An Experimental Study

    Directory of Open Access Journals (Sweden)

    Tirumala Alekhya

    2014-09-01

    Full Text Available Purpose. Kicking, jumping and agility are important skills in football. These activities require adequate lower limb strength, which can be enhanced with resistance training. The objective of the study was to evaluate the effect of resistance tube exercises on kicking accuracy, vertical jump performance and 40-yard technical test results in competitive football players. Methods. The study involved 23 competitive football players (11 males, 12 females aged from 18-20 years recruited from three different universities in Belgaum, Karnataka, India. Back heel kick accuracy, vertical jump height and 40-yard technical test time were evaluated before and after a 2-week resistance tube exercise program. Results. Significant improvements in post-intervention kicking accuracy were found when males and females were treated as a single group (p = 0.01. Vertical jump height also showed a highly significant post-intervention improvement in the males and for the combined group of males and females (p = 0.001. The 40-yard technical test values significantly improved in the females and in the combined results for males and females (p = 0.001. Conclusions. The two-week resistance tube exercise program was found to have an effect on kicking accuracy, vertical jump height and 40-yard technical test performance in competitive football players. Resistance tube exercises can thus be included as a component of a regular strength training program for such athletes.

  20. Fluid Mechanics and Heat Transfer Spirally Fluted Tubing,

    Science.gov (United States)

    1981-08-01

    umik EECTC Dist Special "’hiVUWq d WodI So Ohm% Cdkmu DEC 2 1981 Approved for public releasel D Distribution Unlimited GENERAL ATOMIC PROJECT 3774...bottom and side view from one side when the 16 Fig. 7 Test section casting with plant nirror, ;it ) 17 lighting source was from the opposite side. This

  1. Fluid Mechanics and Heat Transfer Spirally Fluted Tubing.

    Science.gov (United States)

    1984-12-01

    8217- ...................................................................................................................................... 209J N 0 00 S FULLY FULLY ELPI TUBLN rREATMENT REGION 0 0 I 0 - - VISCOSITY A FFECIW SUB LAYER FIG 4.10

  2. Simultaneous heat and mass transfer inside a vertical tube in evaporating a heated falling alcohols liquid film into a stream of dry air

    Science.gov (United States)

    Senhaji, S.; Feddaoui, M.; Mediouni, T.; Mir, A.

    2009-03-01

    A numerical study of the evaporation in mixed convection of a pure alcohol liquid film: ethanol and methanol was investigated. It is a turbulent liquid film falling on the internal face of a vertical tube. A laminar flow of dry air enters the vertical tube at constant temperature in the downward direction. The wall of the tube is subjected to a constant and uniform heat flux. The model solves the coupled parabolic governing equations in both phases including turbulent liquid film together with the boundary and interfacial conditions. The systems of equations obtained by using an implicit finite difference method are solved by TDMA method. A Van Driest model is adopted to simulate the turbulent liquid film flow. The influence of the inlet liquid flow, Reynolds number in the gas flow and the wall heat flux on the intensity of heat and mass transfers are examined. A comparison between the results obtained for studied alcohols and water in the same conditions is made.

  3. Post-dryout heat transfer in a vertical straight tube of a steam generator. Experiments and analytical model

    Energy Technology Data Exchange (ETDEWEB)

    Roko, K.; Shiraha, M. (Kawasaki Heavy Industries Ltd., Akashi, Hyogo (Japan). Technical Inst.)

    1980-09-01

    Importance of the problem of post-dryout heat transfer is increasing in the field of the new technologies being developed lately. This is because the correct understanding of post-dryout heat transfer characteristics together with the position of dryout point is important in designing steam generators and evaluating their safety. By this experiment, the data on the post-dryout heat transfer coefficient in vapor/water system in a vertical straight tube by sodium heating were obtained in the ranges of pressure from 8.2 to 14.3 MPa and mass flow from 240 to 550 kg/m/sup 2/s, for the straight tube steam generators for fast breeder reactors. Based on the result, the investigation by the comparison with the existing correlating equations showed that all equations except the Remizov's equation gave considerably higher values than the experimental value, and the difference was larger as the pressure and flow rate were lower. Next, from the viewpoint that the thermal non-equilibrium of droplets and vapor basically governs the post-dryout heat transfer, the initial diameter of droplets was arranged in the form of a correlating equation after establishing an analytical model and determining the diameter capable of evaluating the experimental values most reasonably. Comparison of the calculated value of heat transfer coefficient by this equation with this experimental value and with the experimental value obtained by electric heating in the region including high flow rate range of 5200 kg/m/sup 2/s or less by Bennett showed good agreement.

  4. Invited guest artist for the Flute Day of the Youth Orchestras of Central Virginia.

    OpenAIRE

    Crone, EL

    2016-01-01

    Solo Recital and Clinic (Flute Hacks) for Flute Day of the Youth Orchestras of Central Virginia. Featured Guest Artist. Sonata in G Minor, S. 1020, J.S. Bach, MidSummer Spirits, J. Sochinski, Twelve Fantasias for Flute, Nos 2 & 9, Telemann, Fantasie for Flute and Piano, G. Fauré, Duo for Flute and Piano, Copland. John Mayhood, piano. Supported by Yamaha. Published (Publication status)

  5. Innovations of Theobald Boehm to the Flute Construction

    Directory of Open Access Journals (Sweden)

    Burcin Barut dikicigiller

    2014-11-01

    Full Text Available Theobald Boehm who had a long life full of creativity, tried to maintain his creativity and performing activities concurrently for almost sixty years in order to bring perfection to the construction of the flute. Two generation flutes that the German master invented in 1832 and 1847 had been one of the most important achievements in the development of the construction of the instrument until that date and those reforms had brought Boehm the reputation which he deserved. Beside from the reforms he made regarding the construction of the flute, Theobald Boehm also stands outs with the musical pieces that he wrote for this instrument. In this study, formation process of the Boehm system flute which is still being used and the evolution of the flute during this process has been analyzed and it has been aimed to relay the importance of Theobald Boehm, who has made a great contribution for the flute to become a solo instrument instead of orchestral instrument and obtain status, in the history of the flute to today’s flautists.

  6. New data on two-phase two-component heat transfer and hydrodynamics in a vertical tube

    Science.gov (United States)

    Rezkallah, K. S.; Sims, G. E.

    1987-06-01

    In forced-convective two-phase, two component (gas-liquid) flow, experimental data for mean heat-transfer coefficients, pressure drop and flow patterns were taken simultaneously for the flow in a 1.17-cm i.d. electrically heated vertical tube using three liquids: water, glycerine and water and silicone liquid with air as the gas phase. The combination of silicone liquid and the glycerine and water solution provided a set of data in which the surface tension changed by a factor of 3.4 (being lower for the silicone liquid) with a rough matching of other hydrodynamic properties and a precise matching of the Prandtl number (63 at 25 C). The flow-pattern results showed a significant change in the bubble-slug boundary for the silicone liquid compared with the glycerine and water solution, while the pressure drop results for silicone-air, in the range of V(SL) between 0.277 and 0.690 m/s at high V(SC) showed a sudden drop in Delta/P(tot) followed by a subsequent increase.

  7. Experimental studies on the enhanced flow boiling heat transfer and pressure drop of organic fluid with high saturation temperature in vertical porous coated tube

    Science.gov (United States)

    Yang, Dong; Shen, Zhi; Chen, Tingkuan; Zhou, Chenn Q.

    2013-07-01

    The characteristics of flow boiling heat transfer and pressure drop of organic fluid with high saturation temperature in a vertical porous coated tube are experimentally studied in this paper. The experiments are performed at evaporation pressure of 0.16-0.31MPa, mass flux of 390-790kg/m2s, and vapor quality of 0.06-0.58. The variations of heat transfer coefficient and pressure drop with vapor quality are measured and compared to the results of smooth tube. Boiling curves are generated at mass flux of 482 and 675kg/m2s. The experimental results indicate that the heat transfer coefficients of the porous tube are 1.8-3.5 times those of smooth tube, and that the frictional pressure drops of the porous tube are 1.1-2.9 times those of smooth tube. The correlations for heat transfer coefficient and frictional pressure drop are derived, in which the effect of fluid molecular weight is included. The experiments show that significant heat transfer enhancement is accompanied by a little pressure drop penalty, the application of the porous coated tube is promising in the process industries.

  8. Jolivet: Complete Flute Music, Vol. 2 / Guy S. Rickards

    Index Scriptorium Estoniae

    Rickards, Guy S.

    1996-01-01

    Uuest heliplaadist "Jolivet: Complete Flute Music, Vol. 2. Kroumata Percussion Ensemble, Tapiola Sinfonietta, Paavo Järvi". BIS CD 739 (64 minutes: DDD). Item marked from CD630 (6/94), CD272, remainder new to UK

  9. Feedback effect on flute dynamics in a mirror machine

    Science.gov (United States)

    Be'Ery, Ilan; Seemann, Omri

    2015-11-01

    Active feedback techniques may stabilize the flute instability in mirror traps and make them viable candidates for fusion machines. A fast feedback with optical sensors and electrical actuators was implemented in a table-top mirror machine and used to study several aspects of feedback stabilization. For a cold, dense plasma the feedback reduces dramatically the flute amplitude of the first two mode. For higher temperature plasma, a significant increase of plasma density due to feedback stabilization is also demonstrated. The effect of changing feedback gain and phase has some interesting feature such as asymmetry with respect to positive and negative phase shifts and non-monotonic dependence of flute amplitude on feedback gain. These effects are explained using simplified analytic model of the flute and feedback.

  10. Passive Fluidic Chip Composed of Integrated Vertical Capillary Tubes Developed for On-Site SPR Immunoassay Analysis Targeting Real Samples

    Directory of Open Access Journals (Sweden)

    Tsuneyuki Haga

    2012-05-01

    Full Text Available We have successfully developed a surface plasmon resonance (SPR measurement system for the on-site immunoassay of real samples. The system is composed of a portable SPR instrument (290 mm(W x 160 mm(D x 120 mm(H and a microfluidic immunoassay chip (16 mm(W x 16 mm(D x 4 mm(H that needs no external pump system. An integrated vertical capillary tube functions as a large volume (150 μL passive pump and a waste reservoir that has sufficient capacity for several refill operations. An immunoassay was carried out that employed the direct injection of a buffer and a test sample in sequence into a microfluidic chip that included 9 antibody bands and 10 reference reagent bands immobilized in the flow channel. By subtracting a reliable averaged reference sensorgram from the antibody, we effectively reduced the influence of the non-specific binding, and then our chip successfully detected the specific binding of spiked IgG in non-homogeneous milk. IgG is a model antigen that is certain not to be present in non-homogeneous milk, and non-homogeneous milk is a model of real sample that includes many interfering foreign substances that induce non-specific binding. The direct injection of a real sample with no pretreatment enabled us to complete the entire immunoassay in several minutes. This ease of operation and short measuring time are acceptable for on-site agricultural, environmentaland medical testing.

  11. Heat transfer, pressure drop and void fraction in two- phase, two-component flow in a vertical tube

    Science.gov (United States)

    Sujumnong, Manit

    1998-09-01

    There are very few data existing in two-phase, two- component flow where heat transfer, pressure drop and void fraction have all been measured under the same conditions. Such data are very valuable for two-phase heat-transfer model development and for testing existing heat-transfer models or correlations requiring frictional pressure drop (or wall shear stress) and/or void fraction. An experiment was performed which adds markedly to the available data of the type described in terms of the range of gas and liquid flow rates and liquid Prandtl number. Heat transfer and pressure drop measurements were taken in a vertical 11.68-mm i.d. tube for two-phase (gas-liquid) flows covering a wide range of conditions. Mean void fraction measurements were taken, using quick- closing valves, in a 12.7-mm i.d. tube matching very closely pressures, temperatures, gas-phase superficial velocities and liquid-phase superficial velocities to those used in the heat-transfer and pressure-drop experiments. The gas phase was air while water and two aqueous solutions of glycerine (59 and 82% by mass) were used as the liquid phase. In the two-phase experiments the liquid Prandtl number varied from 6 to 766, the superficial liquid velocity from 0.05 to 8.5 m/s, and the superficial gas velocity from 0.02 to 119 m/s. The measured two-phase heat-transfer coefficients varied by a factor of approximately 1000, the two-phase frictional pressure drop ranged from small negative values (in slug flow) to 93 kPa and the void fraction ranged from 0.01 to 0.99; the flow patterns observed included bubble, slug, churn, annular, froth, the various transitions and annular-mist. Existing heat-transfer models or correlations requiring frictional pressure drop (or wall shear stress) and/or void fraction were: tested against the present data for mean heat-transfer coefficients. It was found that the methods with more restrictions (in terms of the applicable range of void fraction, liquid Prandtl number or liquid

  12. Eccentric-fluted beam pipes to damp quadrupole higher-order modes

    Directory of Open Access Journals (Sweden)

    M. Sawamura

    2010-02-01

    Full Text Available An eccentric-fluted beam pipe is proposed to damp quadrupole modes in a cavity. The eccentric flutes act as a mode converter from quadrupole to dipole. Optimizing the parameters of the eccentric-fluted beam pipe allows sufficient damping of both degenerate quadrupole modes. The external Q values of the eccentric-fluted beam pipe measured with a low power model cavity agree well with those calculated with the 3D electromagnetic field simulation code MAFIA.

  13. Eccentric-fluted beam pipes to damp quadrupole higher-order modes

    Science.gov (United States)

    Sawamura, M.; Furuya, T.; Sakai, H.; Takahashi, T.; Umemori, K.; Shinoe, K.

    2010-02-01

    An eccentric-fluted beam pipe is proposed to damp quadrupole modes in a cavity. The eccentric flutes act as a mode converter from quadrupole to dipole. Optimizing the parameters of the eccentric-fluted beam pipe allows sufficient damping of both degenerate quadrupole modes. The external Q values of the eccentric-fluted beam pipe measured with a low power model cavity agree well with those calculated with the 3D electromagnetic field simulation code MAFIA.

  14. A Little Flute Music: Mimicry, Memory, and Narrativity

    Directory of Open Access Journals (Sweden)

    Vicki Powys

    2013-11-01

    Full Text Available A lyrebird chick was raised in captivity in the 1920s in Australia’s New England Tablelands, or so the story goes. The bird mimicked the sounds of the household’s flute player, learning two tunes and an ascending scale. When released back into the wild, his flute-like songs and timbre spread throughout the local lyrebird population. We count ourselves among those who admire the sonic achievements of this bioregion’s “flute lyrebirds.” These Superb Lyrebirds (Menura novaehollandiae do indeed deliver an unusual and extraordinarily complex, flute-like territorial song, although often with a musical competence exceeding what a human flutist could achieve. In this paper, we engage with both the living and the dead across a wide-ranging cast of characters, linking up in the here and now and grasping a hand across the span of many years. Memory and narrativity are pertinent to the at times conflicting stories and reminiscences from archival and contemporary sources. Ultimately, accounts of “flute lyrebirds” speak to how meaning evolves in the tensions, boundaries, and interplay between knowledge and imagination. We conclude that this story exceeds containment, dispersed as it is across several fields of inquiry and a number of individual memories that go in and out of sync.

  15. TONE DEVELOPMENT STUDIES WITH A STUDENT DURING FLUTE EDUCATION

    Directory of Open Access Journals (Sweden)

    Begum Aytemur

    2016-12-01

    Full Text Available This research investigated the effect of a five stage study program applied by the researcher to one student who had entered university playing the flute, but who had not resolved lip and tone problems in one educational semester through basic long sound studies and scale studies. The participant in the research was a 19 year old student who had completed first year of the music teaching program and had performed in the year-end concert; however she was criticized by listeners and flute teachers for forced and scratchy tone. The research had the basic aim of solving these problems. As a result the “single subject study model”, chosen for research on individuals requesting private training, was chosen for this research model. The findings of the study were collected as video recordings of scale, study and piece work in initial, training and final stages of a six-week education course run every day. To evaluate the obtained recordings, a “Behavior for Quality Flute Tone Scale” was created. The video recordings were investigated by three flute teaching staff, expert in the area, who provided points in accordance with the scale. The obtained points were analyzed using the SPSS 15.0 program. The results showed that the study program created by the researcher provided rapid tonal development of the student. It is considered that the study is important to present an alternative route for flute students experiencing similar problems.

  16. Condensation of Refrigerant-11 on the outside of horizontal and inclined enhanced tubes

    Energy Technology Data Exchange (ETDEWEB)

    Domingo, N.

    1982-12-01

    Heat transfer condensation tests with Refrigerant-11 were performed on the outside of a smooth tube and a variety of enhanced tubes oriented horizontally and at various tube inclinations. One smooth tube and seven enhanced (externally fluted, roped, spiraled, and externally finned) tubes of 2.54-cm (1-in.) nominal outside diameter and 1.17-m (4-ft) length were tested. Several of the tested tubes featured internal enhanced geometries, which were caused by the heat transfer enhancing geometry on the tube's external surface. Condensing heat transfer coefficients are reported as composite coefficients, which combine the resistance of the condensing film and the tube wall, and are based on total tube outside surface area. Results show that in the horizontal condensing mode, the rank order (best to worst) of the tube geometries tested was spiral-shaped tubes, rope-shaped tubes, smooth tube, externally finned tube, and externally fluted tube. For a spiral-shaped tube, horizontal composite coefficients were up to 2.0 times the corresponding horizontal smooth tube values. For tilt angles greater than or equal to 60/sup 0/ from the horizontal, the condensing performance of the externally fluted tube was best of all the tubes tested.

  17. Effects of diameter and helical angle of flute on the flow evenness of ...

    African Journals Online (AJOL)

    In this study, the optimum dimensions of flute diameter and helical angle of fluted roller used in seed drills were determined for lentil seeds at 100 kg ha-1 of seed rate. The values of coefficient variation were used to determine the optimum dimensions of fluted rollers. The best rates of flow evenness and the minimum ...

  18. FluTE, a publicly available stochastic influenza epidemic simulation model

    National Research Council Canada - National Science Library

    Chao, Dennis L; Halloran, M Elizabeth; Obenchain, Valerie J; Longini, Jr, Ira M

    2010-01-01

    ..., FluTE. FluTE is an individual-based model capable of simulating the spread of influenza across major metropolitan areas or the continental United States. The model's structure is based on previously published work [3,6], but FluTE incorporates a more sophisticated natural history of influenza, more realistic intervention strategies, and ...

  19. Chest wall dynamics and muscle recruitment during professional flute playing.

    Science.gov (United States)

    Cossette, Isabelle; Monaco, Pierpaolo; Aliverti, Andrea; Macklem, Peter T

    2008-02-01

    Respiratory parameters and sound were recorded during professional flute playing in order to assess what physiological processes were associated with the control of sound production that results in 'breath support' which in turn is associated with high quality playing. Four standing young professional flautists played flute excerpts with and without breath support. Recordings included optoelectronic plethysmographic measurements of chest wall volume (V(cw)) and its compartments, surface electromyography of the scalene, lateral abdominal, rectus abdominus, parasternal and sternocleidomastoid muscles, mouth pressure, and sound. Flow was estimated from differentiating V(cw) during playing. Results showed that flute support entails antagonistic contraction of non-diaphragmatic inspiratory muscles that tends to hold the rib cage at higher lung volume. This relieves the expiratory muscles from the task of producing the right mouth pressure, especially at the end of the phrases, so they can contribute more to the finer control of mouth pressure modulations required for high quality playing.

  20. Low-frequency flute instabilities of a bounded plasma column.

    Science.gov (United States)

    Rognlien, T. D.

    1973-01-01

    Derivation of exact solutions for unstable waves (called flute waves) which occur in a radially bounded plasma column at frequencies below the ion cyclotron frequency. Both analytical and numerical solutions are presented for the m = 1 and m = 2 azimuthal modes for a variety of radial electric field profiles. It is shown that the behavior of the flute waves can depend sensitively on the radial extent of the plasma column. Moreover, it is found that the m = 1 mode and the m = 2 mode do not respond in the same way to changes in the radial boundary position or in the electric field profile.

  1. Modifications of ORNL's computer programs MSF-21 and VTE-21 for the evaluation and rapid optimization of multistage flash and vertical tube evaporators

    Energy Technology Data Exchange (ETDEWEB)

    Glueckstern, P.; Wilson, J.V.; Reed, S.A.

    1976-06-01

    Design and cost modifications were made to ORNL's Computer Programs MSF-21 and VTE-21 originally developed for the rapid calculation and design optimization of multistage flash (MSF) and multieffect vertical tube evaporator (VTE) desalination plants. The modifications include additional design options to make possible the evaluation of desalting plants based on current technology (the original programs were based on conceptual designs applying advanced and not yet proven technological developments and design features) and new materials and equipment costs updated to mid-1975.

  2. Residual Effect of Chromium on Early Growth of Fluted Pumpkin ...

    African Journals Online (AJOL)

    Michael Horsfall

    Residual Effect of Chromium on Early Growth of Fluted Pumpkin (Telfairia occidentalis Hook F) in an Ultisol. 1*ORHUE, E R;2UZU, F O. 1Department of Soil Science, 2Department of Soil Science, Faculty of Agriculture, University of Benin, Benin City, Edo State, Nigeria. ABSTRACT: These greenhouse and field trials were ...

  3. Residual Effect of Chromium on Early Growth of Fluted Pumpkin ...

    African Journals Online (AJOL)

    These greenhouse and field trials were aimed at determining the residual influence of Cr on some agronomic characters, nutrient content, nutrient uptake and crude protein content of fluted pumpkin in soils previously treated with 0, 50, 100, 200 mg Cr(NO3). .9H2O per 5 kg soil in the greenhouse and 0, 20, 40, 80 kgha-1 Cr ...

  4. Reinvigorating the indigenous flute in African dance performance ...

    African Journals Online (AJOL)

    Over the decades, scholars and performing arts practitioners have failed to adequately develop the indigenous musical aerophone instruments such as the flute, especially for purposes of communication in contemporary milieus, given the scientific and technological trends in a globalized world. The study is of the ...

  5. Finite Larmor radius flute mode theory with end loss

    Energy Technology Data Exchange (ETDEWEB)

    Kotelnikov, I.A. [AN SSSR, Novosibirsk (Russian Federation). Inst. Yadernoj Fiziki; Berk, H.L. [Texas Univ., Austin, TX (United States). Inst. for Fusion Studies

    1993-08-01

    The theory of flute mode stability is developed for a two-energy- component plasma partially terminated by a conducting limiter. The formalism is developed as a preliminary study of the effect of end-loss in open-ended mirror machines where large Larmor radius effects are important.

  6. Pre-School Children's Encounters with "The Magic Flute"

    Science.gov (United States)

    Nyland, Berenice; Acker, Aleksandra; Ferris, Jill; Deans, Jan

    2011-01-01

    This article describes a music programme in an Australian early learning centre. Through a repertoire of songs, games and instruments, the children were introduced to music forms, including opera. Mozart's Magic Flute was presented to these children by watching the Metropolitan Opera's latest film performance. Because this opera seized the…

  7. Effects of processing on the nutritional composition of fluted pumpkin ...

    African Journals Online (AJOL)

    Fluted pumpkin seeds were processed into the raw, boiled, fermented, germinated and roasted seeds, dried at 500C, milled and sieved. The seed flours were analyzed for nutritional composition, energy, amino acids and fatty acids of the oils. Processing affected the levels of nutrients in the seed. The energy values ranged ...

  8. Garry Disher's "Bamboo Flute": Negotiating Multiple Aesthetic Responses.

    Science.gov (United States)

    Day, Karen S.

    2000-01-01

    Discusses the integration of photographs and text in fictional works specifically regarding Garry Disher's "Bamboo Flute." Introduces the story and explores questions in detail regarding the presentation of its photographs in American publications. Attempts to make the readers become aware of alternative reading strategies that expand…

  9. Nonlinear behavior of the tarka flute's distinctive sounds

    Science.gov (United States)

    Gérard, Arnaud; Yapu-Quispe, Luis; Sakuma, Sachiko; Ghezzi, Flavio; Ramírez-Ávila, Gonzalo Marcelo

    2016-09-01

    The Andean tarka flute generates multiphonic sounds. Using spectral techniques, we verify two distinctive musical behaviors and the nonlinear nature of the tarka. Through nonlinear time series analysis, we determine chaotic and hyperchaotic behavior. Experimentally, we observe that by increasing the blow pressure on different fingerings, peculiar changes from linear to nonlinear patterns are produced, leading ultimately to quenching.

  10. Compression Behavior of Fluted-Core Composite Panels

    Science.gov (United States)

    Schultz, Marc R.; Oremont, Leonard; Guzman, J. Carlos; McCarville, Douglas; Rose, Cheryl A.; Hilburger, Mark W.

    2011-01-01

    In recent years, fiber-reinforced composites have become more accepted for aerospace applications. Specifically, during NASA s recent efforts to develop new launch vehicles, composite materials were considered and baselined for a number of structures. Because of mass and stiffness requirements, sandwich composites are often selected for many applications. However, there are a number of manufacturing and in-service concerns associated with traditional honeycomb-core sandwich composites that in certain instances may be alleviated through the use of other core materials or construction methods. Fluted-core, which consists of integral angled web members with structural radius fillers spaced between laminate face sheets, is one such construction alternative and is considered herein. Two different fluted-core designs were considered: a subscale design and a full-scale design sized for a heavy-lift-launch-vehicle interstage. In particular, axial compression of fluted-core composites was evaluated with experiments and finite-element analyses (FEA); axial compression is the primary loading condition in dry launch-vehicle barrel sections. Detailed finite-element models were developed to represent all components of the fluted-core construction, and geometrically nonlinear analyses were conducted to predict both buckling and material failures. Good agreement was obtained between test data and analyses, for both local buckling and ultimate material failure. Though the local buckling events are not catastrophic, the resulting deformations contribute to material failures. Consequently, an important observation is that the material failure loads and modes would not be captured by either linear analyses or nonlinear smeared-shell analyses. Compression-after-impact (CAI) performance of fluted core composites was also investigated by experimentally testing samples impacted with 6 ft.-lb. impact energies. It was found that such impacts reduced the ultimate load carrying capability by

  11. Two-phase flow characteristics of liquid nitrogen in vertically upward 0.5 and 1.0 mm micro-tubes: Visualization studies

    Science.gov (United States)

    Zhang, P.; Fu, X.

    2009-10-01

    Application of liquid nitrogen to cooling is widely employed in many fields, such as cooling of the high temperature superconducting devices, cryosurgery and so on, in which liquid nitrogen is generally forced to flow inside very small passages to maintain good thermal performance and stability. In order to have a full understanding of the flow and heat transfer characteristics of liquid nitrogen in micro-tube, high-speed digital photography was employed to acquire the typical two-phase flow patterns of liquid nitrogen in vertically upward micro-tubes of 0.531 and 1.042 mm inner diameters. It was found from the experimental results that the flow patterns were mainly bubbly flow, slug flow, churn flow and annular flow. And the confined bubble flow, mist flow, bubble condensation and flow oscillation were also observed. These flow patterns were characterized in different types of flow regime maps. The surface tension force and the size of the diameter were revealed to be the major factors affecting the flow pattern transitions. It was found that the transition boundaries of the slug/churn flow and churn/annular flow of the present experiment shifted to lower superficial vapor velocity; while the transition boundary of the bubbly/slug flow shifted to higher superficial vapor velocity compared to the results of the room-temperature fluids in the tubes with the similar hydraulic diameters. The corresponding transition boundaries moved to lower superficial velocity when reducing the inner diameter of the micro-tubes. Time-averaged void fraction and heat transfer characteristics for individual flow patterns were presented and special attention was paid to the effect of the diameter on the variation of void fraction.

  12. Effect of cutting flute design on cortical bone screw insertion torque and pullout strength.

    Science.gov (United States)

    Yerby, S; Scott, C C; Evans, N J; Messing, K L; Carter, D R

    2001-01-01

    To determine the effect of the number and length of cutting flutes on the insertion torque and pullout strength for self-tapping 4.5-millimeter cortical bone screws. Screws were self-tapped in the diaphysis of human cadaver femurs. Each of the six screw types studied had different designs with varying cutting flute lengths and numbers. Bone mineral density, insertion torque, and pullout strength were measured. The study was conducted at an experimental biomechanics laboratory associated with a university medical center. Insertion torque and pullout strength were normalized by the local bone mineral density. The mean normalized insertion torque of the design with four full-length cutting flutes was less than the design with three full-length flutes and the two designs with one-third length flutes (p flutes was significantly greater than that of all screws with fewer than three flutes (p flute design should ideally include ease of screw insertion, minimal soft tissue irritation, and maximal screw holding power. Screws with more than two flutes were easier to insert and did not cause cortical damage during insertion. The screw with four full-length flutes showed a trend toward being the easiest to insert and having the greatest holding strength.

  13. Nonlinear Finite Element Analysis of the Fluted Corrugated Sheet in the Corrugated Cardboard

    Directory of Open Access Journals (Sweden)

    Zhiguo Zhang

    2014-01-01

    Full Text Available The choice of corrugated medium, flute size, combining adhesive, and linerboards can be varied to design a corrugated board with specific properties. In this paper, the nonlinear finite element analysis of the fluted corrugated sheet in the corrugated cardboard based on software SolidWorks2008 was investigated. The model of corrugated board with three or more flutes is reliable for stress and displacement measurement to eliminate the influence of the number of flutes in models. According to the static pressure test, with the increase of flute height H or arc radius of flute, the maximum stress in the models decreased and the maximum displacement increased. However the maximum stress and maximum displacement in the models increase nonlinearly in the static pressure test with the increase of the flute angle θ. According to the drop test, with the increase of flute height H, the maximum stress of goods on the upper board in the drop test decreased. The maximum stress of the model in the drop test decreases firstly and then increases with the increase of flute angle, and the optimal flute angle θ could be 60° for corrugated board. All the conclusions are consistent with experimental data or product standards.

  14. Investigation on hole manufacture in 42CrMo4 steel using 3-flute carbide drills and 6-flute cermet reamers

    DEFF Research Database (Denmark)

    Müller, Pavel; De Chiffre, Leonardo

    2009-01-01

    An investigation on cutting forces and hole quality using carbide 3-flute self-centering drills and 6-flute cermet reamers was performed on 42CrMo4 alloy steel. Different depths of cuts were analyzed with respect to cutting thrust and cutting torque, hole diameter, form and surface integrity. Good...

  15. Using Lorentz forces to control the distribution of bubbles in a vertical tube filled with liquid metal

    Science.gov (United States)

    Heitkam, S.; Tschisgale, S.; Krull, B.; Wetzel, T.; Baake, E.; Fröhlich, J.

    2017-07-01

    In this work, a method to increase the residence time of bubbles in tubes or pipes filled with liquid metal is investigated. Imposing a horizontal electric current and a perpendicular horizontal magnetic field generates an upward-directed Lorentz force. This force can counteract gravity and cause floating of bubbles. Even with homogeneous electric fields these float in the mean but fluctuate randomly within the swarm due to mutual interactions. In the present case the cylindrical shape of the container furthermore creates inhomogeneous electric currents and an inhomogeneous force distribution resulting in a macroscopic convection pattern stirring the bubbles and further homogenising the spatial distribution of the bubbles.

  16. Development of a Convective Heat Transfer Correlation of a Supercritical CO{sub 2} with Vertical Downward Flow in Circular Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Tae Ho; Kim, Hwan Yeol; Bae, Yoon Yeong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    Pressure of coolant flowing through a SCWR core subchannel is supercritical and the heat transfer behavior is known to be quite different from those at a subcritical pressure. Therefore the heat transfer study in a supercritical pressure is required for the acquisition of a reliable heat transfer correlation. A downward flow as well as an upward flow occurs in a multi-pass reactor core. The heat transfer at a supercritical pressure in downward channel has been known to result in a quite different behavior from an upward flow. An experiment for a supercritical CO{sub 2} flowing vertically downward in circular tubes with inner diameters of 6.32 mm and 9 mm was performed by using SPHINX(Supercritical Pressure Heat transfer Investigation for NeXt generation) at KAERI. The obtained test results are compared with the estimations from the existing correlations and an empirical formula for a downward flow is suggested.

  17. Non-iterative model for condensation heat transfer in presence of non-condensable gases inside passive containment cooling vertical tubes

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Juan Carlos de la [Department of Chemical and Nuclear Engineering, Institute of Energetic Engineering, Polytechnic University of Valencia, Camino de Vera, 14, 46022 Valencia (Spain)], E-mail: juadela3@upvnet.upv.es; Munoz-Cobo, Jose L.; Escriva, Alberto [Department of Chemical and Nuclear Engineering, Institute of Energetic Engineering, Polytechnic University of Valencia, Camino de Vera, 14, 46022 Valencia (Spain)

    2008-01-15

    Some contributions have been stated in order to improve the modeling of concurrent downflow condensation in presence of non-condensables inside vertical tubes. In particular, the influence of non-condensables over the liquid side heat transfer has been considered. The new proposed mechanistic models solve explicitly the real interface temperature by means of a cubic or a fourth order equation. As these models have a non-iterative nature, they can avoid the weakest point of the traditional mechanistic models, which is the slowdown computation if the model had to be implemented in a code. Moreover, as the main non-condensables effects can be accounted for in the heat and mass transfer processes, the new models will be more realistic. The models have been validated with the Vierow experimental data, obtaining a total average relative error, for the fourth order equation method model, of 21% for 268 points.

  18. The Development of the Flute as a Solo Instrument from the Medieval to the Baroque Era

    Directory of Open Access Journals (Sweden)

    Anna J. Reisenweaver

    2011-05-01

    Full Text Available As one of the oldest instruments known to mankind, the flute is present in some form in nearly every culture and ethnic group in the world. However, in Western music in particular, the flute has taken its place as an important part of musical culture, both as a solo and an ensemble instrument. The flute has also undergone its most significant technological developments in Western musical culture, moving from the bone keyless flutes of the Prehistoric era to the gold and silver instruments known to performers today. During the Renaissance and Baroque periods in particular, however, the flute rose to popularity as a solo instrument and began to evolve into its modern form. New developments in the design and mechanics of the instrument drove this increased interest, which ultimately gave the flute a prominent position in music that has lasted throughout history.

  19. Numerical investigation of saturated upward flow boiling of water in a vertical tube using VOF model: effect of different boundary conditions

    Science.gov (United States)

    Hasanpour, B.; Irandoost, M. S.; Hassani, M.; Kouhikamali, R.

    2018-01-01

    In this paper a numerical simulation of upward two-phase flow evaporation in a vertical tube has been studied by considering water as working fluid. To this end, the computational fluid dynamic simulations of this system are performed with heat and mass transfer mechanisms due to energy transfer during the phase change interaction near the heat transfer surface. The volume of fluid model in an available Eulerian-Eulerian approach based on finite volume method is utilized and the mass source term in conservation of mass equation is implemented using a user defined function. The characteristics of water flow boiling such as void fraction and heat transfer coefficient distribution are investigated. The main cause of fluctuations on heat transfer coefficient and volume fraction is velocity increment in the vapor phase rather than the liquid phase. The case study of this research including convective heat transfer coefficient and tube diameter are considered as a parametric study. The operating conditions are considered at high pressure in saturation temperature and the physical properties of water are determined by considering system's inlet temperature and pressure in saturation conditions. Good agreement is achieved between the numerical and the experimental values of heat transfer coefficients.

  20. Morphometric analysis of shank-to-flute ratio in rotary nickel-titanium files.

    Science.gov (United States)

    Biz, M T; Figueiredo, J A P

    2004-06-01

    To evaluate the shank-to-flute ratio in rotary nickel-titanium (Ni-Ti) instruments. The cutting portion of 15 size 30 Ni-Ti rotary instruments, ProFile.04, ProFile.06, Pow R.02, Pow R.04 and Quantec series 2000, were examined. The handles of the instruments were fixed to a bench and supported by a removable resin base. The cutting portion was then manually abraded with abrasive strips along one aspect of their length. All instruments were fixed in a stub that permitted the adaptation and inspection of six instruments at the same time. A scanning electron microscope (SEM; Phillips model XL 20; Eindhmoven, the Netherlands) at x60 magnification was used to collect cross-sectional measurements of the shank and the flutes at the first, third and fifth flutes from the tip. The software autocad 2000 was used to measure these areas. The shank percentage value was, on average, equal to or greater than the flute percentage value at the sites analyzed. A regular and proportional pattern of increase of shank and flute measurements, as well as the ratio between them, was preserved. There was no significant difference between instruments and between flute sites on the same instrument (P > 0.05). However, the Quantec instruments had a flute area twice the flute area of the other instruments. The instruments had a shank percentage measurement value equal to or greater than the flute percentage value; the cross-sectional shank-to-flute ratio was preserved. The instruments had similar shank areas, but the flute area of the Quantec instruments was twice their shank area; i.e. the design of the Quantec files provides longitudinal reinforcement by means of a gain in flute area.

  1. Jet offset, harmonic content, and warble in the flute.

    Science.gov (United States)

    Coltman, John W

    2006-10-01

    The effects of jet offset in the flute, directing the jet above or below the edge, were explored by two distinct means-experiments with a Boehm flute sounded by an artificial blower, and time domain simulation. Very large changes in harmonic content and dynamics were observed, changing greatly with blowing pressure. Warble, a modulation of the tone at frequencies of the order of 20 Hz, was observed both in the experiment and in the simulation. The phenomenon is explained as a beat between the frequency of a second harmonic generated by nonlinearity in the jet current and a neighboring partial sustained by jet feedback near the second mode resonance. A second type of warble, in which amplitude modulation occurs in all partials but with different phases, is yet to be explained.

  2. Diffusivités thermiques horizontale et verticale dans un lit fluidisé avec un faisceau de tubes verticaux Lateral and Vertical Thermal Diffusivities in a Dense Fluidized Bed with Tubes Bundle

    Directory of Open Access Journals (Sweden)

    Collantes M. A.

    2006-11-01

    dimensionnement d'unités de grandes tailles. Dense fluidized beds are acknowledged as homogeneous systems from both temperature and composition aspects. However, some situations such as very large units or fluidized beds with tubes bundle lead to thermal gradients within the bed. These thermal gradients are due to solids motion limitation and may have detrimental effects on the process. This paper relates investigations aiming at determining lateral and vertical thermal diffusivities in a dense fluidized bed with and without a tubes bundle. These investigations have been carried out with an experimental setup of significant size (bed size = 0. 6 x 1. 1 x 1. 3 and with small particles (less 500 microns so as to fill some gaps of the literature. Thermal diffusivities have been deduced from temperature gradients measured between a hot wall and a cold wall in a perpendicular fluidized bed and by applying a conventional 2-D conduction model. Lateral thermal conductivities as well as vertical thermal conductivities increase with the gas velocity and the height of the bed, and when the particle size decreases. Immersing a vertical tube bundle into the fluidized bed leads to a significant reduction of the lateral thermal diffusivity, while there is no effect on the vertical thermal diffusivity. Correlations have been drawn from the experimental results. They would have to be applied for calculation of any system running at gas velocity ranging from 0. 05 to 0. 3 m/s and with particle size between 50 and 300 microns.

  3. Heat Transfer Characteristics for an Upward Flowing Supercritical Pressure CO{sub 2} in a Vertical Circular Tube

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Deog Ji

    2008-02-15

    The SCWR(Super Critical Water-cooled Reactor) is one of the feasible options for the 4th generation nuclear power plant, which is being pursued by an international collaborative organization, the Gen IV International Forum(GIF). The major advantages of the SCWR include a high thermal efficiency and a maximum use of the existing technologies. In the SCWR, the coolant(water) of a supercritical pressure passes the pseudo-critical temperature as it flows upward through the sub-channels of the fuel assemblies. At certain conditions a heat transfer deterioration occurs near the pseudo-critical temperature and it may cause an excessive rise of the fuel surface temperature. Therefore, an accurate estimation of the heat transfer coefficient is necessary for the thermal-hydraulic design of the reactor core. A test facility, SPHINX(Supercritical Pressure Heat Transfer Investigation for the Next Generation), dedicated to produce heat transfer data and study flow characteristics, uses supercritical pressure CO{sub 2} as a surrogate medium to take advantage of the relatively low critical temperature and pressure: and similar physical properties with water. The produced data includes the temperature of the heating surface and the heat transfer coefficient at varying mass fluxes, heat fluxes, and operating pressures. The test section is a circular tube of ID 6.32 mm: it is almost the same as the hydraulic diameter of the sub-channel in the conceptional design presented by KAERI. The test range of the mass flux is 285 to 1200 kg/m{sup 2}s and the maximum heat flux is 170 kW/m{sup 2}. The tests were mainly performed for an inlet pressure of 8.12 MPa which is 1.1 times of critical pressure. With the test results of the wall temperature and the heat transfer coefficient, effects of mass flux, heat flux, inlet pressure, and the tube diameter on the heat transfer were studied. And the test results were compared with the existing correlations of the Nusselt number. In addition, New

  4. Heat Transfer Characteristics and Prediction Model of Supercritical Carbon Dioxide (SC-CO2 in a Vertical Tube

    Directory of Open Access Journals (Sweden)

    Can Cai

    2017-11-01

    Full Text Available Due to its distinct capability to improve the efficiency of shale gas production, supercritical carbon dioxide (SC-CO2 fracturing has attracted increased attention in recent years. Heat transfer occurs in the transportation and fracture processes. To better predict and understand the heat transfer of SC-CO2 near the critical region, numerical simulations focusing on a vertical flow pipe were performed. Various turbulence models and turbulent Prandtl numbers (Prt were evaluated to capture the heat transfer deterioration (HTD. The simulations show that the turbulent Prandtl number model (TWL model combined with the Shear Stress Transport (SST k-ω turbulence model accurately predicts the HTD in the critical region. It was found that Prt has a strong effect on the heat transfer prediction. The HTD occurred under larger heat flux density conditions, and an acceleration process was observed. Gravity also affects the HTD through the linkage of buoyancy, and HTD did not occur under zero-gravity conditions.

  5. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    Science.gov (United States)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2017-10-01

    conductive sub-layer δ CSL and the nondimensional thickness of the conductive sub-layer y + CSL on the circular tubes with various twisted-tape inserts were determined on the basis of numerical solutions for the swirl velocities u sw ranging from 5.23 to 21.18 m/s. Correlations between the conductive sub-layer thickness δ CSL and the nondimensional thickness of the conductive sub-layer y + CSL for twisted-tape-induced swirl-flow heat transfer in a vertical circular tube were derived.

  6. Experimental study of heat transfer during pseudo-dropwise condensation of water-ethanol and water-isopropanol vapor mixtures on a vertical tube

    Science.gov (United States)

    Chindyakov, A. A.; Smirnov, Yu B.; Vinogradov, A. A.; Mikhailova, E. V.

    2017-11-01

    In the present study experimental heat transfer data on condensation of almost immobile water-ethanol and water-isopropanol vapor mixtures on the vertical smooth copper tube 100 mm long with an outer diameter of 12.0 mm were obtained. Experiments for water-ethanol mixture were carried out at mass concentrations of ethanol from 0.4 to 16% in the vapor phase, and for a water-isopropanol mixture - from 0.6 to 8.4%. The pressure was 0.12…0.13 MPa, vapor-to-surface temperature difference varied from 2 to 40K. The experimental data are represented as dependency of heat transfer coefficient and heat flux on the vapor-to-surface temperature difference. The results of high-speed photography of the condensation process are discussed. It is noted that the transition from film mode to pseudo-dropwise condensation occurs when vapor-to-surface temperature difference is close to dew point - bubble point temperature difference for a given composition of the mixture. According to experimental data, the diffusion thermal resistance and thermal resistance of the liquid phase at different concentrations of the mixture were calculated.

  7. Glacial flutings in bedrock, an observation in East Greenland

    DEFF Research Database (Denmark)

    Funder, Svend Visby

    1978-01-01

    and 5 m in height and occur between 50 and 250 m above sea level inthe gently sloping lowland area adjacent to the fjord. They were probably formed beneath the lateral part of the former Harefjord-Glacier which receded rapidly in the fjord and exposed the area at c. 7500 years BP. Large scale glacial...... flutings have not been recorded before in Greenland, but seem to be of common occurrence in parts of North America. They have probably been formed near the margin of actively moving glaciers, and secondary flow in the basal ice may have played an important role...

  8. FLUTE: A versatile linac-based THz source

    Energy Technology Data Exchange (ETDEWEB)

    Nasse, M. J.; Schuh, M.; Schwarz, M. [Laboratory for Applications of Synchrotron Radiation (LAS), Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe (Germany); Naknaimueang, S.; Mathis, Y.-L.; Rossmanith, R.; Wesolowski, P.; Huttel, E. [ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Plech, A. [Institute for Photon Science and Synchrotron Radiation (IPS), Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Schmelling, M. [Max Planck Institute for Nuclear Physics (MPIK), 69117 Heidelberg (Germany); Mueller, A.-S. [Laboratory for Applications of Synchrotron Radiation (LAS), Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe (Germany); ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Institute for Photon Science and Synchrotron Radiation (IPS), Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany)

    2013-02-15

    A new compact versatile linear accelerator named FLUTE is currently being designed at the Karlsruhe Institute of Technology. This paper presents the status of this 42 MeV machine. It will be used to generate strong (several 100 MV/m) ultra-short ({approx}1 ps) THz pulses (up to {approx}4-25 THz) for photon science experiments, as well as to conduct a variety of accelerator studies. The latter range from comparing different coherent THz radiation generation schemes to compressing electron bunches and studying the electron beam stability. The bunch charge will cover a wide range ({approx}100 pC-3 nC). Later we plan to also produce ultra-short x-ray pulses from the electron bunches, which, for example, could then be combined for THz pump-x-ray probe experiments.

  9. FLUTE: a versatile linac-based THz source.

    Science.gov (United States)

    Nasse, M J; Schuh, M; Naknaimueang, S; Schwarz, M; Plech, A; Mathis, Y-L; Rossmanith, R; Wesolowski, P; Huttel, E; Schmelling, M; Müller, A-S

    2013-02-01

    A new compact versatile linear accelerator named FLUTE is currently being designed at the Karlsruhe Institute of Technology. This paper presents the status of this 42 MeV machine. It will be used to generate strong (several 100 MV/m) ultra-short (~1 ps) THz pulses (up to ~4-25 THz) for photon science experiments, as well as to conduct a variety of accelerator studies. The latter range from comparing different coherent THz radiation generation schemes to compressing electron bunches and studying the electron beam stability. The bunch charge will cover a wide range (~100 pC-3 nC). Later we plan to also produce ultra-short x-ray pulses from the electron bunches, which, for example, could then be combined for THz pump-x-ray probe experiments.

  10. Surface flute waves in plasmas theory and applications

    CERN Document Server

    Girka, Volodymyr; Thumm, Manfred

    2014-01-01

    The book presents results of a comprehensive study of various features of eigen electromagnetic waves propagating across the axis of plasma filled metal waveguides with cylindrical geometry. The authors collected in one book material on various features of surface flute waves, i. e. impact of waveguide design on wave dispersion, wave damping influenced by various reasons, impact of plasma density and external magnetic field inhomogeneity on the wave, and impact of waveguide corrugation and electric current on the wave. A variety of present surface waves applications and possible future applications is also included. Using the method of successive approximations it is shown how one can solve problems, which concern real experimental devices, starting from simple models. The book applies to both professionals dealing with problems of confined plasmas and to graduate and post-graduate students specializing in the field of plasma physics and related applications.

  11. The impact of a modified cutting flute implant design on osseointegration.

    Science.gov (United States)

    Jimbo, R; Tovar, N; Marin, C; Teixeira, H S; Anchieta, R B; Silveira, L M; Janal, M N; Shibli, J A; Coelho, P G

    2014-07-01

    Information concerning the effects of the implant cutting flute design on initial stability and its influence on osseointegration in vivo is limited. This study evaluated the early effects of implants with a specific cutting flute design placed in the sheep mandible. Forty-eight dental implants with two different macro-geometries (24 with a specific cutting flute design - Blossom group; 24 with a self-tapping design - DT group) were inserted into the mandibular bodies of six sheep; the maximum insertion torque was recorded. Samples were retrieved and processed for histomorphometric analysis after 3 and 6 weeks. The mean insertion torque was lower for Blossom implants (Pdesign (Blossom group). Implants with the modified cutting flute design had a significantly reduced insertion torque compared to the DT implants with a traditional cutting thread, and resulted in a different healing pattern. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Discrimination between Tone Quality and Intonation in Unaccompanied Flute/Oboe Duets.

    Science.gov (United States)

    Madsen, Clifford K.; Geringer, John M.

    1981-01-01

    Reports the results of a study that investigated patterns of judgmental discriminations and preferences with regard to tone quality versus intonation of accompanied flute and oboe duet performances of simple melodies among music and nonmusic graduate and undergraduate students. (AM)

  13. Life history of the fluted kidneyshell Ptychobranchus subtentum

    Science.gov (United States)

    Davis, V.M.; Layzer, J.B.

    2012-01-01

    The fluted kidneyshell Ptychobranchus subtentum (Say, 1825) is a candidate for listing under the Endangered Species Act by the US Fish and Wildlife Service. Fecundity, fish hosts, and selected population demographics were determined during 2005–2006 for the fluted kidneyshell in the upper Clinch River, Hancock County, Tennessee. Females were fertilized in Aug. within a 5 d period and contained viable glochidia about 4 wk later. As the embryos began to develop, the marsupium gradually changed color from white to dark brown. Glochidia were contained within conglutinates that resemble Simuliidae pupae likely to attract benthic insectivorous fish and were held over winter and released in May. Fecundity was positively related to mussel length (r2  =  0.81) and ranged from 43,000 to 500,000 glochidia. Eight species of darters (Etheostoma spp. and Percina spp.) were infested with glochidia in the laboratory to examine potential hosts and host suitability. Juveniles transformed on bluebreast darters E. camurum and dusky darters P. scieraand previously reported hosts: rainbow darters E. caeruleum and fantail darters E. flabellare. In addition, fantail darters and rainbow darters were infested with glochidia from two river systems. The median time of glochidial metamorphosis did not differ significantly between the two mussel populations. The observed ratio of adult females to males (1.9∶1) in the Clinch River differed significantly from 1∶1. Based upon thin-sections, individuals live to at least 26 y and females become sexually mature at age five.

  14. Subcooled boiling heat transfer in a short vertical SUS304-tube at liquid Reynolds number range 5.19 x 10{sup 4} to 7.43 x 10{sup 5}

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Koichi, E-mail: hata@iae.kyoto-u.ac.j [Institute of Advanced Energy, Kyoto Univ., Gokasho, Uji, Kyoto 611-0011 (Japan); Masuzaki, Suguru, E-mail: masuzaki@LHD.nifs.ac.j [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki, Gifu 509-5292 (Japan)

    2009-12-15

    The subcooled boiling heat transfer and the steady-state critical heat fluxes (CHFs) in a short vertical SUS304-tube for the flow velocities (u = 17.28-40.20 m/s), the inlet liquid temperatures (T{sub in} = 293.30-362.49 K), the inlet pressures (P{sub in} = 842.90-1467.93 kPa) and the exponentially increasing heat input (Q = Q{sub 0} exp(t/tau), tau = 8.5 s) are systematically measured by the experimental water loop comprised of a multistage canned-type circulation pump with high pump head. The SUS304 test tubes of inner diameters (d = 3 and 6 mm), heated lengths (L = 33 and 59.5 mm), effective lengths (L{sub eff} = 23.3 and 49.1 mm), L/d (=11 and 9.92), L{sub eff}/d (=7.77 and 8.18), and wall thickness (delta = 0.5 mm) with average surface roughness (Ra = 3.18 mum) are used in this work. The inner surface temperature and the heat flux from non-boiling to CHF are clarified. The subcooled boiling heat transfer for SUS304 test tube is compared with our Platinum test tube data and the values calculated by other workers' correlations for the subcooled boiling heat transfer. The influence of flow velocity on the subcooled boiling heat transfer and the CHF is investigated into details and the widely and precisely predictable correlation of the subcooled boiling heat transfer for turbulent flow of water in a short vertical SUS304-tube is given based on the experimental data. The correlation can describe the subcooled boiling heat transfer obtained in this work within 15% difference. Nucleate boiling surface superheats for the SUS304 test tube become very high. Those at the high flow velocity are close to the lower limit of Heterogeneous Spontaneous Nucleation Temperature. The dominant mechanisms of the flow boiling CHF in a short vertical SUS304-tube are discussed.

  15. CO2 volume fluxes outgassing from champagne glasses in tasting conditions: flute versus coupe.

    Science.gov (United States)

    Liger-Belair, Gérard; Villaume, Sandra; Cilindre, Clara; Polidori, Guillaume; Jeandet, Philippe

    2009-06-10

    Measurements of CO(2) fluxes outgassing from glasses containing a standard Champagne wine initially holding about 11.5 g L(-1) of dissolved CO(2) were presented, in tasting conditions, during the first 10 min following the pouring process. Experiments were performed at room temperature, with a flute and a coupe, respectively. The progressive loss of dissolved CO(2) concentration with time was found to be significantly higher in the coupe than in the flute, which finally constitutes the first analytical proof that the flute prolongs the drink's chill and helps it to retain its effervescence in contrast with the coupe. Moreover, CO(2) volume fluxes outgassing from the coupe were found to be much higher in the coupe than in the flute in the early moments following pouring, whereas this tendency reverses from about 3 min after pouring. Correlations were proposed between CO(2) volume fluxes outgassing from the flute and the coupe and their continuously decreasing dissolved CO(2) concentration. The contribution of effervescence to the global kinetics of CO(2) release was discussed and modeled by use of results developed over recent years. Due to a much shallower liquid level in the coupe, bubbles collapsing at the free surface of the coupe were found to be significantly smaller than those collapsing at the free surface of the flute, and CO(2) volume fluxes released by collapsing bubbles only were found to be approximately 60% smaller in the coupe than in the flute. Finally, the contributions of gas discharge by invisible diffusion through the free surface areas of the flute and coupe were also approached and compared for each type of drinking vessel.

  16. Analysis of Lung Flute-collected Sputum for Lung Cancer Diagnosis.

    Science.gov (United States)

    Su, Jian; Anjuman, Nigar; Guarnera, Maria A; Zhang, Howard; Stass, Sanford A; Jiang, Feng

    2015-01-01

    Molecular analysis of sputum can help diagnose lung cancer. We have demonstrated that Lung Flute can be used to collect sputum from individuals who cannot spontaneously expectorate sputum. The objective of this study is to further evaluate the performance of the Lung Flute by comparing the characteristics of parallel samples collected with and without the Lung Flute and the usefulness for diagnosis of lung cancer. Fifty-six early-stage lung cancer patients (40 current smokers and 16 former smokers) and 73 cancer-free individuals (52 current smokers and 21 former smokers) were instructed to spontaneously cough and use Lung Flute for sputum sampling. Sputum cytology and polymerase chain reaction analysis of three miRNAs (miRs-21, 31, and 210) were performed in the specimens. All 92 current smokers and 11 (28.7%) of 37 former smokers spontaneously expectorated sputum and also produced sputum when using the Lung Flute. Twenty-seven former smokers (70.3%) who could not spontaneously expectorate sputum, however, were able to produce sputum when using the Lung Flute. The specimens were of low respiratory origin without contamination from other sources, eg, saliva. There was no difference of sputum volume and cell populations, diagnostic efficiency of cytology, and analysis of the miRNAs in the specimens collected by the two approaches. Analysis of the sputum miRNAs produced 83.93% sensitivity and 87.67% specificity for identifying lung cancer. Therefore, sputum collected by the Lung Flute has comparable features as spontaneously expectorated sputum. Using the Lung Flute enables former smokers who cannot spontaneously expectorate to provide adequate sputum to improve sputum collection for lung cancer diagnosis.

  17. Experimental Study of the Compression Response of Fluted-Core Composite Panels with Joints

    Science.gov (United States)

    Schultz, Marc R.; Rose, Cheryl A.; Guzman, J. Carlos; McCarville, Douglas; Hilburger, Mark W.

    2012-01-01

    Fluted-core sandwich composites consist of integral angled web members spaced between laminate face sheets, and may have the potential to provide benefits over traditional sandwich composites for certain aerospace applications. However, fabrication of large autoclave-cured fluted-core cylindrical shells with existing autoclaves will require that the shells be fabricated in segments, and joined longitudinally to form a complete barrel. Two different longitudinal fluted-core joint designs were considered experimentally in this study. In particular, jointed fluted-core-composite panels were tested in longitudinal compression because longitudinal compression is the primary loading condition in dry launch-vehicle barrel sections. One of the joint designs performed well in comparison with unjointed test articles, and the other joint design failed at loads approximately 14% lower than unjointed test articles. The compression-after-impact (CAI) performance of jointed fluted-core composites was also investigated by testing test articles that had been subjected to 6 ft-lb impacts. It was found that such impacts reduced the load-carrying capability by 9% to 40%. This reduction is dependent on the joint concept, component flute size, and facesheet thickness.

  18. Flute and Shank Dimensions of Reciprocating Instruments before and after Simulated Root Canal shaping.

    Science.gov (United States)

    Sampaio, Felipe C; Brito, Ana Pp; Veloso, Heloisa Hp; de Alencar, Ana Hg; Decurcio, Daniel de A; de Figueiredo, José Ap; Estrela, Carlos

    2017-03-01

    This study analyzed the effect of the dimensions of the flute and shank in the first 4 mm of instrument tips on the deformation and dimensional changes of reciprocating instruments after root canal shaping (RCS). The reciprocating instruments used were Reciproc ® R25, R40, and R50; WaveOne ® Small, Primary, and Large; and Unicone ® #20, #25, and #40. Scanning electron microscopy images of the first 4 mm of the tip were acquired at 30× magnification before and after simulated curved root canals were shaped. Each instrument was used only once. The images were transferred to the AxioVision ® software to measure the flute area (μm 2 ), shank area (μm 2 ), flute length (μm), and cross-sectional diameter (μm). Student's t test for paired samples was used to compare differences before and after RCS, and analysis of variance followed by the Tukey test, to compare differences between instruments of similar sizes. The instruments were classified according to deformations after RCS. Reciproc ® instruments had larger flutes and smaller shanks. The Reciproc ® R40 had significant differences in cross-sectional diameter at 0.5 mm from the tip. Reciproc ® had no plastic deformations. Unicone ® #20 instruments had significant differences in cross-sectional diameter at 1.5 and 3.0 mm from the tip, and #25 instruments had differences at 1.5 and 3.0 mm and in length of the second and third flutes. One #20 and three #40 instruments had plastic deformations. The differences in length of the first and fourth flutes of WaveOne ® Primary and in cross-sectional diameter at 2.0 mm from the tip of WaveOne ® Large were significant. Two of three WaveOne ® Large instruments had plastic deformations. Reciproc ® instruments had greater flute areas and lengths and smaller shanks than Unicone ® and WaveOne ® instruments of similar sizes. Reciproc ® instruments had a greater flute-to-shank ratio. WaveOne ® instruments had the lowest flute-to-shank ratio. Unicone ® instruments

  19. Incompressible magnetohydrodynamic modes in the thin magnetically twisted flux tube

    Science.gov (United States)

    Cheremnykh, O. K.; Fedun, V.; Kryshtal, A. N.; Verth, G.

    2017-08-01

    Context. Observations have shown that twisted magnetic fields naturally occur, and indeed are omnipresent in the Sun's atmosphere. It is therefore of great theoretical interest in solar atmospheric waves research to investigate the types of magnetohydrodynamic (MHD) wave modes that can propagate along twisted magnetic flux tubes. Aims: Within the framework of ideal MHD, the main aim of this work is to investigate small amplitude incompressible wave modes of twisted magnetic flux tubes with m ≥ 1. The axial magnetic field strength inside and outside the tube will be allowed to vary, to ensure the results will not be restricted to only cold plasma equilibria conditions. Methods: The dispersion equation for these incompressible linear MHD wave modes was derived analytically by implementing the long wavelength approximation. Results: It is shown, in the long wavelength limit, that both the frequency and radial velocity profile of the m = 1 kink mode are completely unaffected by the choice of internal background magnetic twist. However, fluting modes with m ≥ 2 are sensitive to the particular radial profile of magnetic twist chosen. Furthermore, due to background twist, a low frequency cut-off is introduced for fluting modes that is not present for kink modes. From an observational point of view, although magnetic twist does not affect the propagation of long wavelength kink modes, for fluting modes it will either work for or against the propagation, depending on the direction of wave travel relative to the sign of the background twist.

  20. Characterization of chlorinated solvent contamination in limestone using innovative FLUTe® technologies in combination with other methods in a line of evidence approach

    DEFF Research Database (Denmark)

    Broholm, Mette Martina; Janniche, Gry Sander; Mosthaf, Klaus

    2016-01-01

    , hydrogeology and contaminant distribution. The FACT™ is a new technology and it was applied and tested at a contaminated site with a limestone aquifer, together with a number of existing methods including wire-line coring with core subsampling, FLUTe® transmissivity profiling and multilevel water sampling....... Laboratory sorption studies were combined with a model of contaminant uptake on the FACT™ for data interpretation. Limestone aquifers were found particularly difficult to sample with existing methods because of core loss, particularly from soft zones in contact with chert beds. Water FLUTe™ multilevel...... were able to provide detailed vertical profiles of DNAPL and contaminant distributions, water flows and fracture zones in the aquifer and are therefore a powerful tool for site investigation. For the limestone aquifer the results indicate horizontal spreading in the upper crushed zone, vertical...

  1. Flute ``breath support'' perception and its acoustical correlates

    Science.gov (United States)

    Cossette, Isabelle A.; Sabourin, Patrick

    2004-05-01

    Music educators and performers commonly refer to ``breath support'' in flute playing, yet the term ``support'' is neither well-defined nor consistently used. Different breathing strategies used by professional flautists who were instructed to play with and without support were previously identified by the authors. In the current study, 14 musical excerpts with and without support were recorded by five professional flautists. Eleven professional flautists listened to the recordings in a random order and ranked (1 to 6) how much of the following sound qualities they judged to be in each example: support, intonation, control and musical expressiveness. Answers to the test showed that musical expressiveness was associated more closely with the supported excerpts than the answers about support itself. The ratings for each sound quality were highly intercorrelated. Acoustical parameters were analyzed (frequency and centroid variation within each note) and compared with the results of the perception test in order to better understand how the acoustical and psychological variables were related. The acoustical analysis of the central part of the notes did not show evident correlation with the answers of the perception test. [Work funded by the Social Sciences and Humanities Research Council of Canada.

  2. Detecting overblown flute fingerings from the residual noise spectrum.

    Science.gov (United States)

    Verfaille, Vincent; Depalle, Philippe; Wanderley, Marcelo M

    2010-01-01

    Producing a tone by increasing the blowing pressure to excite a higher frequency impedance minimum, or overblowing, is widely used in standard flute technique. In this paper, the effect of overblowing a fingering is explored with spectral analysis, and a fingering detector is designed based on acoustical knowledge and pattern classification techniques. The detector performs signal analysis of the strong broadband signal, that is, spectrally shaped by the pipe impedance, and measures the spectral energy during the attack around multiples of the fundamental frequency sub-multiples over the first octave and a half. It is trained and evaluated on sounds recorded with four expert performers. They played six series of tones from overblown and regular fingerings, with frequencies that are octave- and non-octave-related to the playing frequency. The best of the four proposed sound descriptors allows for a detection error below 1.3% for notes with two and three fingerings (C(5), D(5), C(6), and Cmusical sharp(6)) and below 14% for four (E(6)) or five fingerings (G(6)). The error is shown to dramatically increase when two fingerings' impedance become too similar (E(6) and A(4) and G(6) and C(5)).

  3. Combined use of straddle packer testing and FLUTe profiling for hydraulic testing in fractured rock boreholes

    Science.gov (United States)

    Quinn, Patryk; Cherry, John A.; Parker, Beth L.

    2015-05-01

    A combination of high resolution hydraulic tests using straddle packers and transmissivity (T) profiling using the FLUTe flexible liner method (liner profiling) in densely fractured rock boreholes is shown to be efficient for the determination of the vertical distribution of T along the entire hole. The liner T profiling method takes a few hours or less to scan the entire borehole length resulting in a T profile. Under favorable conditions this method has good reliability for identifying the highest T zones identified by distinct decreases in liner velocity when these zones are covered by the descending liner. In contrast, for one short test interval (e.g., 1-2 m) the multiple-test, straddle-packer method takes a few hours to measure T with good precision and accuracy using a combination of steady-state and transient tests (e.g., constant head step tests, slug tests, and constant rate pumping tests). Because of the time consuming aspect of this multiple-test method, it is most efficient in each borehole to conduct straddle packer testing only in priority zones selected after assessment of other borehole data collected prior to packer testing. The T profile from the liner method is instrumental in selecting high permeable zones for application of the multiple-test method using straddle packers, which in turn, refines the T estimation from the liner profile. Results from three boreholes in densely fractured sandstone demonstrate this approach showing the synergistic use of the methods with emphasis on information important for determining hydraulic apertures.

  4. Novel method for sputum induction using the Lung Flute in patients with suspected pulmonary tuberculosis.

    Science.gov (United States)

    Fujita, Akira; Murata, Kengo; Takamori, Mikio

    2009-08-01

    The Lung Flute is a small self-powered audio device that generates sound waves, which vibrate in tracheobronchial secretions. This was a preliminary trial to evaluate the usefulness of the Lung Flute for sputum sampling in patients suspected of pulmonary tuberculosis (TB). Thirty-four patients who were not expectorating sputum, but for whom sputum examination was required for the differential diagnosis of TB or other diseases, were enrolled in the study. Patients were instructed to blow out fast and hard through the Lung Flute and to repeat this for a total 20 sets of two blows each. Using the Lung Flute, sputum samples were collected within 10 or 20 min from 30 of 34 patients (88%). The device permitted a rapid diagnosis of TB in seven of 15 confirmed TB cases. In three patients acid-fast bacillus smears were positive. In four patients acid-fast bacillus smears were negative, but PCR tests for TB were positive. Hyperventilation-related symptoms occurred in three patients. The application of the Lung Flute may represent a promising technique for the rapid diagnosis of pulmonary TB.

  5. Color removal from textile wastewater by using treated flute reed in a fixed bed column.

    Science.gov (United States)

    Inthorn, Duangrat; Tipprasertsin, Kannika; Thiravetyan, Paitip; Khan, Eakalak

    2010-01-01

    This study investigated the ability of acid treated flute reed to adsorb color (dye) from synthetic reactive dye solutions, and actual dyeing and printing textile wastewaters in a laboratory scale fixed bed column. The effects of particle size, initial reactive dye concentration, bed depth and flow rate on adsorption performances were examined. The results from experiments with synthetic reactive dye solutions showed that the volume treated (until the breakthrough occurred) increased with decreasing particle size, influent reactive dye concentration and flow rate, and increasing bed depth. The bed depth service time model was suitable for describing the experimental data. The treated flute reed was able to reduce color efficiently, 99% for dyeing textile wastewater with ten adsorption columns in series and 78% for printing textile wastewater with a single adsorption column. The difference in the numbers of columns used for the two types of actual textile wastewater led to a substantial discrepancy in suspended solids removal, 99% for dyeing wastewater and 12% for printing wastewater. Similar pH and chemical oxygen demand (COD) results were obtained for the two types of textile wastewater. The acid pretreatment of flute reed resulted in dramatic decreases in pH after the adsorption and very acidic effluents (pH 3). Increases of COD after the adsorption due to organic leaching from the treated flute reed were observed. A different pretreatment method to solve these pH and COD problems is needed before flute reed can be used in practice.

  6. The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants.

    Science.gov (United States)

    Wu, Shu-Wei; Lee, Chia-Ching; Fu, Ping-Yuen; Lin, Shang-Chih

    2012-09-01

    Easy insertion of the implant and stable bone purchase is essential for an ideal dental implantation. At the implant tip, the cutting flutes and conical profile are respectively designed to reduce insertion resistance and facilitate the initial insertion. However, the tapered tip might reduce the self-tapping and bone-purchasing abilities of the flutes and the tip threads. Using sawbone blocks as standard specimens, this study experimentally measures the insertion torque, holding power, and bending strength of eight varieties of implant (4 shapes×2 profiles). The bony contact, interfacial mechanism, and the altered shape of the flutes, at different section planes, are used to explain the experimental results. The results reveal that the bone-implant gaps at the tip region significantly suppress both the self-tapping and bone-purchasing abilities of the flutes and the tip threads. This makes initial insertion of the conical implant easier. However, the conical implant eventually requires a higher insertion torque and holding power, due to tighter bony contact, at the tail threads. The bowl-fluted design has the least flute space to store the squeezed bone chips, so both insertion torque and bending strength are significantly higher. For the conical group, the holding powers of three flute designs are nearly comparable. Overall, the conical implant with bowl flutes is the optimal design, with a lower resistance to initial insertion and higher stability, for final instrumentation. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. A 3D numerical simulation of mixed convection of a magnetic nanofluid in the presence of non-uniform magnetic field in a vertical tube using two phase mixture model

    Energy Technology Data Exchange (ETDEWEB)

    Aminfar, Habib, E-mail: hh_aminfar@tabrizu.ac.i [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of); Mohammadpourfard, Mousa, E-mail: Mohammadpour@azaruniv.ed [Department of Mechanical Engineering, Azarbaijan University of Tarbiat Moallem, Tabriz, P.O. Box 53751-71379 (Iran, Islamic Republic of); Narmani Kahnamouei, Yousef, E-mail: Narmani87@ms.tabrizu.ac.i [Faculty of Mechanical Engineering, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2011-08-15

    In this paper, results of applying a non-uniform magnetic field on a ferrofluid (kerosene and 4 vol% Fe{sub 3}O{sub 4}) flow in a vertical tube have been reported. The hydrodynamics and thermal behavior of the flow are investigated numerically using the two phase mixture model and the control volume technique. Two positive and negative magnetic field gradients have been examined. Based on the obtained results the Nusselt number can be controlled externally using the magnetic field with different intensity and gradients. It is concluded that the magnetic field with negative gradient acts similar to Buoyancy force and augments the Nusselt number, while the magnetic field with positive gradient decreases it. Also with the negative gradient of the magnetic field, pumping power increases and vice versa for the positive gradient case. - Highlights: We model hydrothermal behavior of a ferrofluid flow using two phase mixture model. Various external non-uniform magnetic fields were implemented in a vertical tube. Nusselt number can be controlled using the magnetic field with different gradients. The magnetic field is more effective in low Reynolds numbers. Heat transfer enhancement using the magnetic field needs high pumping power.

  8. Development and Performance Evaluation of Fluted Pumpkin Seed Dehulling Machine

    Directory of Open Access Journals (Sweden)

    M. M. Odewole

    2017-08-01

    Full Text Available A machine for dehulling fluted pumpkin seed (Telfairia occidentalis was developed. The main objective of developing the machine was to provide a better substitute to traditional methods of dehulling the seed which contains edible oil of high medicinal and nutritional values. Traditional methods are full of drudgery, slow, injury prone and would lead to low and poor outputs in terms of quantity and quality of dehulled products. The machine is made of five major parts: the feed hopper (for holding the seeds to be dehulled before getting into the dehulling chamber, dehulling chamber (the part of the machine that impacts forces on seeds thereby causing fractures and opening of seeds coats for the delivery of the oily kernels, discharge unit (exit for oily kernels and seed coats after dehulling, the frame (for structural support and stability of all parts of the machine and electric motor (power source of the machine.The development process involved design of major components (shaft diameter (20 mm, machine velocity (7.59 m/s, power requirement (3hp single phase electric motor and structural support of mild steel angle iron, selection of construction materials and fabrication. ANSYS R14.5 machine design computer software was used to design the shaft and structural support; while other components were designed with conventional design method of using design equations. The machine works on the principle of centrifugal and impact forces. Performance evaluation was carried out after fabrication and 87.26%, 2.83g/s, 8.9% and 3.84%were obtained for dehulling efficiency, throughput capacity, percentage partially dehulled and percentage undehulled respectively.

  9. Studies of bunch length and charge for the planned THz source, FLUTE

    Energy Technology Data Exchange (ETDEWEB)

    Naknaimueang, Somprasong [Karlsruhe Institute of Technology, Karlsruhe (Germany); Collaboration: FLUTE-Collaboration

    2013-07-01

    FLUTE is a THz source consisting of a 7 MeV photon gun, a 40 to 50 MeV linac, and a bunch compressor. The gun can produce up to 3 nC electron bunches which are several picoseconds long. At high charges, the transverse and longitudinal beam sizes are limited by space charge effects. In addition, coherent synchrotron radiation effects in the compressor limit the minimum obtainable bunch length in this case. The relationship between bunch charge and obtainable bunch length for a FLUTE-type accelerator is discussed.

  10. Evaporation and diffusion of ammonia in a gaseous mixture of hydrogen inside a vertical open tube in laminar natural convection - a numerical model

    Energy Technology Data Exchange (ETDEWEB)

    Martins, G.; Pereira, J. T. V.

    1996-11-01

    Natural convection flow and heat and mass transfer resulting from the combined effects of thermal and mass diffusion occurring in the evaporator of a triple-fluid (NH{sub 3}-H{sub 2}O-H{sub 2}) absorption refrigeration system was studied by modelling. Significant similarities between the boundary conditions of constant heat flux and convective condition with similar heat flux densities were observed. Overall results led to the conclusion that the geometric parameters of the tube, such as length and radius, are by far the most important influencing parameters in the characteristics of the buoyancy flow induced inside the tube. The absorber of this this type of refrigeration system also has been studied by modelling. In this case the attention was focused on counter-current fluid flow. It was suggested that the model described here could be used as an efficient tool in designing, simulating and optimizing evaporators in absorption refrigeration systems. 22 refs., 14 figs.

  11. The flute melody: The experience of mystique in the contemporary context

    Directory of Open Access Journals (Sweden)

    Luiz Siveres

    2015-04-01

    Full Text Available Mystique is an essential dimension of human condition which could be exercised in different ways through the relationship of a person with oneself, with others and with the transcendent. From our point of view, mystique has historically been linked to religious institutions or incorporated into spiritual experiences, disfiguring it’s specificity to be understood as an inner energy, a movement of connectivity and a light that illuminates the transcendent. In this sense we propose the metaphor of "flute melody", to express that the flute, as an instrument, identifies itself more with the institutions, the beliefs and the symbols, while the melody is closer from energy, movement and light. Isn’t intended to indicate a preference for one of these aspects, but recover the dimension of the melody, up so that the flute has recognized its own statute, valuing the coexistence, the reciprocity or the dialogical relationship between the flute and the melody. Although making reference to an original experience, on the case of Abraham, in which we found the dynamics of internalization, connection and transcendence, the text was elaborated to be a contribution for the mystical experience in the contemporary context.

  12. Observations on in vitro behaviour of the zygotic axes of fluted ...

    African Journals Online (AJOL)

    AJB SERVER

    2006-08-03

    Aug 3, 2006 ... Fluted pumpkin, Telfairia occidentalis Hook. f., is an important leaf and seed vegetable and a local medicinal plant across West Africa. ... three most widely eaten vegetables at homes and in restaurants across Nigeria ... dehydrated slowly, although axes withstand more water loss on rapid dehydration ...

  13. 77 FR 60803 - Endangered and Threatened Wildlife and Plants; Endangered Species Status for the Fluted...

    Science.gov (United States)

    2012-10-04

    ... water quality parameters necessary for the fluted kidneyshell and the slabside pearlymussel. (5) Current... Department of Fish and Wildlife Resources (KDFWR) translocated 144 individuals from the Clinch River into the... the Slabside Pearlymussel Water body Drainage County State Historical or current Cumberland River...

  14. Effect of plant spacing on weed suppression and yield of fluted ...

    African Journals Online (AJOL)

    The field study was conducted to evaluate the effect of plant spacing on weed suppression yield and economic benefit of fluted pumpkin (Telfeiria occidentalis Hook F). The experiment was carried out at the Department of Crop and Soil Science Demonstration Plot, Faculty of Agriculture, University of Port Harcourt, Nigeria ...

  15. Idea Bank: The Native American Flute--A Possibility for Your Classroom

    Science.gov (United States)

    Kacanek, Hal

    2011-01-01

    The sound of the Native American flute seems to convey care, sadness, loneliness, longing, heartfelt emotion, a sense of the natural world, wisdom, the human spirit, and a sense of culture. It is a sound that competes for attention, dramatically punctuating messages about First Nation peoples on television and in movies. A relatively small group…

  16. Sorption kinetic study on the removal of phenol using fluted pumpkin ...

    African Journals Online (AJOL)

    Batch adsorption experiments were performed to study the removal kinetics of phenol from aqueous solution using activated carbon derived from fluted pumpkin stem waste (FAC) and a commercial activated carbon (CAC). Optimum removal of 98.50% and 98.40% phenol was achieved at the equilibrium time of 60 mins for ...

  17. Anvendelse af Water FLUTe multi-level vandprøvetagning til DNAPL-karakterisering

    DEFF Research Database (Denmark)

    Janniche, Gry Sander; Kerrn-Jespersen, Henriette; Christensen, Anders G.

    2013-01-01

    Denne artikel omhandler erfaringer med anvendelse af en ny metode, Water FLUTe til niveauspecifik vandprøvetagning i fm. karakterisering af DNAPL i et kalkmagasin. Metoden blev anvendt i et samarbejdsprojekt mellem DTU Miljø og Region Hovedstaden om afprøvning af metoder til bestemmelse af DNAPL...

  18. Cascading process in the flute-mode turbulence of a plasma

    Science.gov (United States)

    Gonzalez, R.; Gomez, D.; Fontan, C. F.; Schifino, A. C. S.; Montagne, R.

    1993-01-01

    The cascades of ideal invariants in the flute-mode turbulence are analyzed by considering a statistics based on an elementary three-mode coupling process. The statistical dynamics of the system is investigated on the basis of the existence of the physically most important (PMI) triad. When finite ion Larmor radius effects are considered, the PMI triad describes the formation of zonal flows.

  19. Evaluation of lung flute in sputum samples for molecular analysis of lung cancer.

    Science.gov (United States)

    Anjuman, Nigar; Li, Ning; Guarnera, Maria; Stass, Sanford A; Jiang, Feng

    2013-09-22

    Molecular analysis of sputum provides a promising approach for lung cancer diagnosis, yet is limited by the difficulty in collecting the specimens from individuals who can't spontaneously expectorate sputum. Lung Flute is a small self-powered audio device that can induce sputum by generating sound waves and vibrating in the airways of the lungs. Here we propose to evaluate the usefulness of Lung Flute for sputum sampling to assist diagnosis of lung cancer. Forty-three stage I lung cancer patients and 47 cancer-free individuals who couldn't spontaneously cough sputum were instructed to use Lung Flute for sputum sampling. Expressions of two microRNAs, miRs-31 and 210, were determined in the specimens by qRT-PCR. The results were compared with sputum cytology. Sputum was easily collected from 39 of 43 (90.7%) lung cancer patients and 42 of 47 (89.4%) controls with volume ranges from 1 to 5 ml (median, 2.6 ml). The specimens had less than 4% oral squamous cells, indicating that sputum was obtained from low respiratory tract. Expressions of miRs-31 and 210 in sputum were considerably higher in cancer patients than cancer-free individuals (8.990 vs. 4.514; 0.6847 vs. 0.3317; all P Flute could potentially be useful in convenient and efficient collection of sputum for molecular diagnosis of lung cancer.

  20. The Effects of Verbal Instruction, Modeling, Rehearsal, and Feedback on Correct Posture during Flute Playing

    Science.gov (United States)

    Dib, Nancy Ellen; Sturmey, Peter

    2007-01-01

    A behavioral skills training package, including verbal instruction, modeling, rehearsal, and feedback, was used to teach children correct posture, defined as keeping feet on the floor, legs parallel to each other, and the back and neck perpendicular to the floor, during flute lessons. Three typically developing girls aged 8 to 9 years…

  1. Characterization of chlorinated solvent contamination in limestone using innovative FLUTe® technologies in combination with other methods in a line of evidence approach

    Science.gov (United States)

    Broholm, Mette M.; Janniche, Gry S.; Mosthaf, Klaus; Fjordbøge, Annika S.; Binning, Philip J.; Christensen, Anders G.; Grosen, Bernt; Jørgensen, Torben H.; Keller, Carl; Wealthall, Gary; Kerrn-Jespersen, Henriette

    2016-06-01

    Characterization of dense non-aqueous phase liquid (DNAPL) source zones in limestone aquifers/bedrock is essential to develop accurate site-specific conceptual models and perform risk assessment. Here innovative field methods were combined to improve determination of source zone architecture, hydrogeology and contaminant distribution. The FACT™ is a new technology and it was applied and tested at a contaminated site with a limestone aquifer, together with a number of existing methods including wire-line coring with core subsampling, FLUTe® transmissivity profiling and multilevel water sampling. Laboratory sorption studies were combined with a model of contaminant uptake on the FACT™ for data interpretation. Limestone aquifers were found particularly difficult to sample with existing methods because of core loss, particularly from soft zones in contact with chert beds. Water FLUTe™ multilevel groundwater sampling (under two flow conditions) and FACT™ sampling and analysis combined with FLUTe® transmissivity profiling and modeling were used to provide a line of evidence for the presence of DNAPL, dissolved and sorbed phase contamination in the limestone fractures and matrix. The combined methods were able to provide detailed vertical profiles of DNAPL and contaminant distributions, water flows and fracture zones in the aquifer and are therefore a powerful tool for site investigation. For the limestone aquifer the results indicate horizontal spreading in the upper crushed zone, vertical migration through fractures in the bryozoan limestone down to about 16-18 m depth with some horizontal migrations along horizontal fractures within the limestone. Documentation of the DNAPL source in the limestone aquifer was significantly improved by the use of FACT™ and Water FLUTe™ data.

  2. TUBE TESTER

    Science.gov (United States)

    Gittings, H.T. Jr.; Kalbach, J.F.

    1958-01-14

    This patent relates to tube testing, and in particular describes a tube tester for automatic testing of a number of vacuum tubes while in service and as frequently as may be desired. In it broadest aspects the tube tester compares a particular tube with a standard tube tarough a difference amplifier. An unbalanced condition in the circuit of the latter produced by excessive deviation of the tube in its characteristics from standard actuates a switch mechanism stopping the testing cycle and indicating the defective tube.

  3. Wave function properties of a single and a system of magnetic flux tube(s) oscillations

    Science.gov (United States)

    Esmaeili, Shahriar; Nasiri, Mojtaba; Dadashi, Neda; Safari, Hossein

    2016-10-01

    In this study, the properties of wave functions of the MHD oscillations for a single and a system of straight flux tubes are investigated. Magnetic flux tubes with a straight magnetic field and longitudinal density stratification were considered in zero-β approximation. A single three-dimensional wave equation (eigenvalue problem) is solved for longitudinal component of the perturbed magnetic field using the finite element method. Wave functions (eigenfunction of wave equation) of the MHD oscillations are categorized into sausage, kink, helical kink, and fluting modes. Exact recognition of the wave functions and the frequencies of oscillations can be used in coronal seismology and also helps to the future high-resolution instruments that would be designed for studying the properties of the solar loop oscillations in details. The properties of collective oscillations of nonidentical and identical system of flux tubes and their interactions are studied. The ratios of frequencies, the oscillation frequencies of a system of flux tubes to their equivalent monolithic tube (ω sys/ω mono), are obtained between 0.748 and 0.841 for a system of nonidentical tubes, whereas the related ratios of frequencies for a system of identical flux tubes are fluctuated around 0.761.

  4. Is the jet-drive flute model able to produce modulated sounds like Flautas de Chinos ?

    CERN Document Server

    Terrien, Soizic; De La Cuadra, Patricio; Fabre, Benoît

    2014-01-01

    Flautas de chinos - prehispanic chilean flutes played during ritual celebrations in central Chile - are known to produce very particular beating sounds, the so-called sonido rajado. Some previous works have focused on the spectral analysis of these sounds, and on the input impedance of the complex resonator. However, the beating sounds origin remains to be investigated. Throughout this paper, a comparison is provided between the characteristics of both the sound produced by flautas de chinos and a synthesis sound obtained through time-domain simulation of the jet-drive model for flute-like instruments. Jet-drive model appears to be able to produce quasiperiodic sounds similar to sonido rajado. Finally, the analysis of the system dynamics through numerical continuation methods allows to explore the production mechanism of these quasiperiodic regimes.

  5. Regime change thresholds in flute-like instruments: influence of the mouth pressure dynamics

    CERN Document Server

    Terrien, Soizic; Vergez, Christophe; Fabre, Benoît

    2014-01-01

    Since they correspond to a jump from a given note to another one, the mouth pressure thresholds leading to regime changes are particularly important quantities in flute-like instruments. In this paper, a comparison of such thresholds between an artificial mouth, an experienced flutist and a non player is provided. It highlights the ability of the experienced player to considerabily shift regime change thresholds, and thus to enlarge its control in terms of nuances and spectrum. Based on recent works on other wind instruments and on the theory of dynamic bifurcations, the hypothe- sis is tested experimentally and numerically that the dynamics of the blowing pressure influences regime change thresholds. The results highlight the strong influence of this parameter on thresholds, suggesting its wide use by experienced musicians. Starting from these observations and from an analysis of a physical model of flute-like instruments, involving numerical continuation methods and Floquet stability analysis, a phenomenolo...

  6. Flute-like musical instruments: a toy model investigated through numerical continuation

    CERN Document Server

    Terrien, Soizic; Fabre, Benoît

    2013-01-01

    Self-sustained musical instruments (bowed string, woodwind and brass instruments) can be modeled by nonlinear dynamical systems. Among these instruments, flutes and flue organ pipes present the particularity to be modeled as a delay dynamical system. In this paper, such a system, a toy model of flute-like instruments, is studied using numerical continuation. Equilibrium and periodic solutions are explored with respect to the blowing pressure, with focus on amplitude and frequency evolutions along the different solution branches, as well as "jumps" between periodic solution branches. The influence of a second model parameter (namely the inharmonicity) on the behaviour of the system is addressed. It is shown that harmonicity plays a key role in the presence of hysteresis or quasi-periodic regime. Throughout the paper, experimental results on a real instrument are presented to illustrate various phenomena, and allow some qualitative comparisons with numerical results.

  7. pod portion and type effects on sex, growth and yield in fluted ...

    African Journals Online (AJOL)

    Administrator

    pod type of fluted pumpkin on sex ratio, growth and yield in the crop. ... trois parties (supérieure, terminale et centale) de trois types de gousses (1, 2 et 3) avaient été plantées en 3 x 3 factoriel dans un ... relatifs de plants mâles et femelles par parcelles de graines de la partie superieur, du milieu et les parties terminales.

  8. The Possible Mechanism and Factors Affecting Synthetic Reactive Dye Removal by Treated Flute Reed

    OpenAIRE

    Chatchawan Singhakant

    2010-01-01

    This study investigated the ability of treated flute-reed to adsorb synthetic reactive dye solution in a batch system. The effects of particle size, contact time and adsorption isotherms at various particle sizes and temperatures were investigated. Desorption was studied to confirm the mechanism of adsorption. The results showed that the adsorption capacity increased as the particle size decreased. The smaller particle size required less contact time to reach equilibrium because it had a high...

  9. Development of Table-Top mirror trap for flute stabilization research

    Science.gov (United States)

    Seemann, Omri; Be'Ery, Ilan

    2015-11-01

    Mirror traps might be viable candidates for fusion machines. These machines are technically and physically simple but suffer from the Rayleigh-Taylor-like flute instability. A new table top mirror machine was built in order to research ways to mitigate this instability. One possible solution for this problem which was researched in the past is using oscillatory fields. A description of the system and diagnostics, preliminary results and a review of the main mechanisms with which stabilization might occur are presented.

  10. Music Performance Anxiety: Causes, Symptoms and Coping Strategies for Flute Students

    Directory of Open Access Journals (Sweden)

    Andre Sinico

    2013-05-01

    Full Text Available This article addresses the causes, symptoms and coping strategies used by undergraduate flute students from three universalities in Brazil to cope with music performance anxiety (MPA during jury recitals. The data collection and analysis procedures used were similar to a study by Siw Nielsen (1999, i.e., recital participant behavioral observation and verbal reports using semi-structured interviews. Both procedures were recorded in audio and video. As a result, the study highlights sixteen causes, nineteen symptoms, and eighteen strategies used by flute students to cope with MPA. Anxiety among the participants was constantly present to a greater or lesser degree. Its main cause was the repertoire for solo flute; nervousness was the symptom most reported by the participants; and positive self-talk was the most used coping strategy. The research concluded that, since anxiety is an inherent emotion in performing music, musicians must use a broad range of strategies—before and during the performance—to thoroughly deal with the causes and symptoms of anxiety. The article also highlights the importance of music professors in knowing the causes of MPA and its symptoms so that they can plan a strategy consistent with the needs of their students that will help them cope with the negative effects of anxiety.

  11. Contributing factors, prevention, and management of playing-related musculoskeletal disorders among flute players internationally.

    Science.gov (United States)

    Lonsdale, Karen; Laakso, E-Liisa; Tomlinson, Vanessa

    2014-09-01

    Major studies have shown that flutists report playing-related pain in the neck, middle/upper back, shoulders, wrists, and hands. The current survey was designed to establish the injury concerns of flute players and teachers of all backgrounds, as well as their knowledge and awareness of injury prevention and management. Questions addressed a range of issues including education, history of injuries, preventative and management strategies, lifestyle factors, and teaching methods. At the time of the survey, 26.7% of all respondents were suffering from flute playing-related discomfort or pain; 49.7% had experienced flute playing-related discomfort or pain that was severe enough to distract while performing; and 25.8% had taken an extended period of time off playing because of discomfort or pain. Consistent with earlier studies, the most common pain sites were the fingers, hands, arms, neck, middle/upper back, and shoulders. Further research is needed to establish possible links between sex, instrument types, and ergonomic set up. Further investigation is recommended to ascertain whether certain types of physical training, education, and practice approaches may be more suitable than current methods. A longitudinal study researching the relationship between early education, playing position, ergonomic set-up, and prevalence of injury is recommended.

  12. Incidence of injury and attitudes to injury management in skilled flute players.

    Science.gov (United States)

    Ackermann, Bronwen J; Kenny, Dianna T; Fortune, James

    2011-01-01

    The flute is a highly popular instrument, yet little is known about the potential injury association with playing this instrument. Twenty flautists from a major music training institution volunteered to participate in this project, and had played the flute for a minimum of ten years. A specifically designed musicians' health questionnaire was used to determine injury rates in a group of skilled collegiate flute players majoring in music to examine self-reported perceptions of performance-related musculoskeletal disorder causation and approaches to managing these conditions. All except one player reported suffering from a performance-related musculoskeletal disorder, with pain present for longer than 3 months in two thirds of this group. The most common approach by the flautists was to take Alexander lessons rather than seeking health professional advice. Most attributed their symptoms to long hours of practice, poor posture and the presence of performance anxiety. Flautists in this sample reported high rates of performance-related musculoskeletal disorders with the majority having been present for longer than 3 months. The approach to management often did not involve consultation with a health professional qualified to diagnose musculoskeletal conditions.

  13. Use of the Lung Flute for sputum induction in children with cystic fibrosis: a pilot study.

    Science.gov (United States)

    Doumit, Michael; Jaffé, Adam

    2015-04-01

    This study aimed to assess the effectiveness of the Lung Flute in obtaining a sputum sample from children with cystic fibrosis (CF) that were not productive of sputum with coughing alone. Children attending an outpatient CF clinic who were not able to provide a sample with coughing alone were eligible. Each child used the Lung Flute on two occasions at least one month apart. The primary outcome was expectoration of a sputum sample. Secondary outcomes were sputum microbiology, time taken for the procedure, and ease of use of the device as assessed by the patient using a visual analogue scale (VAS), with 0/10 representing very easy and 10/10 representing very hard. Twenty-five children participated (15 males, mean age 12.7 range 6.5-17.9). Overall, a sputum sample was obtained on 26/50 (52%) uses of the device. In children that presented with a moist cough, a sample was obtained on 17/17 (100%) occasions, compared to 9/33 (27%) occasions when a child presented with a dry cough. A positive culture result for at least one known CF pathogen was found in 24/26 samples. Culture results from obtained samples resulted in management changes in 12 cases. Mean time taken to obtain a sample was 9.8 min (SD 2.2). Mean ease of use on the VAS was 1.5 (SD 1.6). The lung flute appears to be a clinically useful and easy device for sputum induction in children with CF. Further research comparing its effectiveness to other sputum induction methods is warranted. © 2014 Wiley Periodicals, Inc.

  14. Influence of different types of sharpening in straight flute drills on burr formation

    Directory of Open Access Journals (Sweden)

    Rodrigo Barros de Borba

    2016-08-01

    Full Text Available Drilling is among the most important manufacturing processes in modern industry. Information on the dynamics of the drilling process is very important to define optimum input parameters. The minimization of burrs is a great challenge in drilling process. Current analysis was carried out with stepped solid carbide drills with straight flutes in drilling of the aluminum alloy A306. Burr height was measured at hole exits and evaluated with ANOVA technique. Results showed that the feed rate and cutting speed variation exhibited significant influence while sharpening was the most important parameter on burr formation.

  15. Ponderomotive stabilization of flute modes in mirrors Feedback control and numerical results

    Science.gov (United States)

    Similon, P. L.

    1987-01-01

    Ponderomotive stabilization of rigid plasma flute modes is numerically investigated by use of a variational principle, for a simple geometry, without eikonal approximation. While the near field of the studied antenna can be stabilizing, the far field has a small contribution only, because of large cancellation by quasi mode-coupling terms. The field energy for stabilization is evaluated and is a nonnegligible fraction of the plasma thermal energy. A new antenna design is proposed, and feedback stabilization is investigated. Their use drastically reduces power requirements.

  16. Transitions to spatiotemporal chaos and turbulence of flute instabilities in a magnetized plasma.

    Science.gov (United States)

    Brochard, F; Gravier, E; Bonhomme, G

    2006-03-01

    The spatiotemporal transition scenario of flute instabilities from a regular to a turbulent state is experimentally investigated in the plasma column of a thermionic discharge. The same transition scenario, i.e., the Ruelle-Takens route to turbulence, is found for both the Kelvin-Helmholtz and the Rayleigh-Taylor instabilities. It is demonstrated that the transition can be more or less smooth, according to the discharge mode. In both cases, a strong radial dependence is observed, which is linked to the velocity shear layer in the case of the Kelvin-Helmholtz instability.

  17. Flute mode waves near the lower hybrid frequency excited by ion rings in velocity space

    Science.gov (United States)

    Cattell, C.; Hudson, M.

    1982-01-01

    Discrete emissions at the lower hybrid frequency are often seen on the S3-3 satellite. Simultaneous observation of perpendicularly heated ions suggests that these ions may provide the free energy necessary to drive the instability. Studies of the dispersion relation for flute modes excited by warm ion rings in velocity space show that waves are excited with real frequencies near the lower hybrid frequency and with growth rates ranging from about 0.01 to 1 times the ion cyclotron frequency. Numerical results are therefore consistent with the possibility that the observed ions are the free energy source for the observed waves.

  18. Lung flute improves symptoms and health status in COPD with chronic bronchitis: A 26 week randomized controlled trial.

    Science.gov (United States)

    Sethi, Sanjay; Yin, Jingjing; Anderson, Pamela K

    2014-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by mucus hypersecretion that contributes to disease related morbidity and is associated with increased mortality. The Lung Flute® is a new respiratory device that produces a low frequency acoustic wave with moderately vigorous exhalation to increase mucus clearance. We hypothesized that the Lung Flute, used on a twice daily basis will provide clinical benefit to patients with COPD with chronic bronchitis. We performed a 26 week randomized, non-intervention controlled, single center, open label trial in 69 patients with COPD and Chronic Bronchitis. The primary endpoint was change in respiratory symptoms measured with the Chronic COPD Questionnaire (CCQ). Secondary endpoints included health status, assessed by the St. George Respiratory questionnaire (SGRQ), BODE (Body-Mass Index, Airflow Obstruction, Dyspnea, and Exercise Capacity) index score and exacerbation frequency. While the control patients did not demonstrate any significant changes in the primary endpoint (CCQ change at 26 weeks of +0.01, p = 0.8), a trend (p = 0.08) to decrease (improvement) in the CCQ (-0.23 at 26 weeks) was seen with the Lung Flute. Furthermore, a significant improvement in the symptom domain of the CCQ was seen only with the lung flute (-0.42, p = 0.004). Health status (SGRQ) improvement, was also only seen with the Lung Flute (-3.23, p = 0.03). The BODE score increased in the control group (3.31 at baseline, 4.14 at 26 weeks), however it remained stable in the Lung Flute arm (3.16 at baseline and 26 weeks), with the changes from baseline being significantly different between the 2 arms (p = 0.01). There was a trend for less exacerbations in the Lung Flute group (p = 0.07). Adverse effects were minor, with only 1 patient discontinuing treatment because of lack of efficacy. Serious adverse effects seen were all determined to be unrelated to the device use. The Lung Flute is a safe and effective

  19. Comparative biogas generation from fruit peels of fluted pumpkin (Telfairia occidentalis) and its optimization.

    Science.gov (United States)

    Dahunsi, S O; Oranusi, S; Owolabi, J B; Efeovbokhan, V E

    2016-12-01

    This study evaluated the potentials of fluted pumpkin fruit peels for biogas generation using three different pre-treatment methods (A, B, C) and the optimization of its process parameters. The physic-chemical characteristics of the substrates revealed it to be rich in nutrients and mineral elements needed by microorganisms. Gas chromatography analysis revealed the gas composition to be within the range of 58.5±2.5% Methane and 27±3% Carbon dioxide for all the three digestions. The study revealed that combination of three pre-treatment methods enhanced enormous biogas yield from the digested substrates as against the use of two methods and no pre-treatment experiment. Optimization of the generated biogas data revealed that RSM predicted higher gas yield than ANN, the latter gives higher accuracy and efficiency than the former. It is advocated that fluted pumpkin fruit peels be used for energy generation especially in the locations of its abundance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Floral Biology of Fluted Pumpkin (Telfairia occidentalis Hook. F.

    Directory of Open Access Journals (Sweden)

    Lawrence Stephen FAYEUN

    2016-12-01

    Full Text Available Knowledge of floral biology is essential to crop improvement. Ten genotypes of fluted pumpkin (Telfairia occidentalis were observed for floral morphology, phenology and insect visitation for two consecutive years. Functional dioecy of fluted pumpkin was confirmed, whereas none of the studied genotypes was monoecious. Floral structures differed significantly among the genotypes. Both male and female flowers were symmetrical, pentasepalous, fimbriate and non-bright pentapetalous, but male flowers were more numerous. Male inflorescences emerged from 11 to 14 weeks after planting and the female flower buds appeared about 4 weeks later. The flowering period of the male flowers was longer than that of female flowers and both gender flowering periods coincided for a specific interval. It took between 11 to 14 days from bud initiation to anthesis and flowering ceased when there were occurrences of successful fruits set. In both gender flowers petals started unfurling at around 6.00 pm and full bloom was achieved by dawn, while petal shrivelled at sun set (between 6.30 pm to 7.30 pm. The anthers dehisced at anthesis of the male flowers; the pollen grains were whitish and sticky. Only the male flowers have nectar and pollen and this may explain infrequent female flowers visitation. Hover flies (Cheilosia species were the major floral visitors observed.

  1. The Dance of the Dead Rhino: William Kentridge’s Magic Flute

    Directory of Open Access Journals (Sweden)

    Serena Guarracino

    2010-11-01

    Full Text Available The article offers a reading of the staging of The Magic Flute by visual artist William Kentridge, focusing on his introduction of the rhino in the visual landscape of the opera as symbol for the silenced subject of violence. Operatic tradition has always been concerned with the staging of death, in particular with the death of its female protagonists, and recent scholarship has highlighted the complicity of the genre with the ideology of Western patriarchy and colonial violence. In this light, Kentridge's appropriation stages Mozart's opera as both voice of colonial Europe and place of resistance for the postcolonial artist. Kentridge moves the setting of the opera to colonial Africa, and the Flute becomes haunted with the massacre of the Herero people in South West Africa by the German army led by general von Trotha (1904-1907. The African white rhino, a species under the threat of extinction, works in this work as proxy for the missing corpses of the Herero people; in its being subject to humiliation and ruthless murder, it recalls Judith Butler's recent attempt at a different categorization of human life as both a continuous exposure to violence and what can be mourned after death. With its silence among the powerful sounds of Mozart's opera, the body of the dead, dancing rhino stands at the centre of Kentridge's work, which becomes a ceremony of mourning where the Western canon can be made to "resonate differently" (Trinh T. Minh-ha.

  2. Drilling load modeling and validation based on the filling rate of auger flute in planetary sampling

    Directory of Open Access Journals (Sweden)

    Qiquan Quan

    2017-02-01

    Full Text Available Some type of penetration into a subsurface is required in planetary sampling. Drilling and coring, due to its efficient penetrating and cuttings removal characteristics, has been widely applied in previous sampling missions. Given the complicated mechanical properties of a planetary regolith, suitable drilling parameters should be matched with different drilling formations properly. Otherwise, drilling faults caused by overloads could easily happen. Hence, it is necessary to establish a drilling load model, which is able to reveal the relationships among drilling loads, an auger’s structural parameters, soil’s mechanical properties, and relevant drilling parameters. A concept for the filling rate of auger flute (FRAF is proposed to describe drilling conditions. If the FRAF index under one group of drilling parameters is less than 1, this means that the auger flute currently removes cuttings smoothly. Otherwise, the auger will be choked with compressed cuttings. In drilling operations, the drilling loads on the auger mainly come from the conveyance action, while the drilling loads on the drill bit primarily come from the cutting action. Experiments in one typical lunar regolith simulant indicate that the estimated drilling loads based on the FRAF coincide with the test results quite well. Based on this drilling load model, drilling parameters have been optimized.

  3. The Possible Mechanism and Factors Affecting Synthetic Reactive Dye Removal by Treated Flute Reed

    Directory of Open Access Journals (Sweden)

    Chatchawan Singhakant

    2010-07-01

    Full Text Available This study investigated the ability of treated flute-reed to adsorb synthetic reactive dye solution in a batch system. The effects of particle size, contact time and adsorption isotherms at various particle sizes and temperatures were investigated. Desorption was studied to confirm the mechanism of adsorption. The results showed that the adsorption capacity increased as the particle size decreased. The smaller particle size required less contact time to reach equilibrium because it had a higher rate of adsorption. Adsorption isotherms at various particle sizes indicated that the equilibrium data fitted well with the Langmuir isotherm. The maximum adsorption capacity (qmax of particle size ranges of: less than 420, 420-1190, 1190-2000 and 2000-2800 μm, was 7.58, 4.42, 3.83 and 3.12 mg/g, respectively. For adsorption isotherms at various temperatures, the amounts of adsorption increased with increasing temperature. This is because the kinetic energy probably increased at higher temperatures resulting in increasing reactive dye removal. The results from the desorption studies confirmed that the adsorption of reactive dye by treated flute-reed was due to ion exchange and the adsorption mechanism was mainly chemical adsorption.

  4. Individuality of movements in music--finger and body movements during playing of the flute.

    Science.gov (United States)

    Albrecht, Stefan; Janssen, Daniel; Quarz, Esther; Newell, Karl M; Schöllhorn, Wolfgang I

    2014-06-01

    The achievement of mastery in playing a composition by means of a musical instrument typically requires numerous repetitions and corrections according to the keys and notations of the music piece. Nevertheless, differences in the interpretation of the same music piece by highly skilled musicians seem to be recognizable. The present study investigated differences within and between skilled flute players in their finger and body movements playing the same piece several times on the same and on different days. Six semiprofessional and four professional musicians played an excerpt of Mozart's Flute Concerto No. 2 several times on three different days. Finger and body movements were recorded by 3D motion capture and analyzed by linear and nonlinear classification approaches. The findings showed that the discrete and continuous movement timing data correctly identified individuals up to 100% by means of their finger movements and up to 94% by means of their body movements. These robust examples of identifying individual movement patterns contradict the prevailing models of small, economic finger movements that are favored in the didactic literature for woodwind players and question traditional recommendations for teaching the learning of motor skills. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Absorption of water vapour in the falling film of water-(LiBr + LiI + LiNO{sub 3} + LiCl) in a vertical tube at air-cooling thermal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bourouis, Mahmoud; Valles, Manel; Medrano, Marc; Coronas, Alberto [Centro de Innovacion Tecnologica en Revalorizacion Energetica y Refrigeracion, CREVER, Universitat Rovira i Virgili, Autovia de Salou, s/n, 43006, Tarragona (Spain)

    2005-05-01

    In air-cooled water-LiBr absorption chillers the working conditions in the absorber and condenser are shifted to higher temperatures and concentrations, thereby increasing the risk of crystallisation. To develop this technology, two main problems are to be addressed: the availability of new salt mixtures with wider range of solubility than water-LiBr, and advanced absorber configurations that enable to carry out simultaneously an appropriate absorption process and an effective air-cooling. One way of improving the solubility of LiBr aqueous solutions is to add other salts to create multicomponent salt solutions. The aqueous solution of the quaternary salt system (LiBr + LiI + LiNO{sub 3} + LiCl) presents favourable properties required for air-cooled absorption systems: less corrosive and crystallisation temperature about 35 K lower than that of water-LiBr.This paper presents an experimental study on the absorption of water vapour over a wavy laminar falling film of an aqueous solution of (LiBr + LiI + LiNO{sub 3} + LiCl) on the inner wall of a water-cooled smooth vertical tube. Cooling water temperatures in the range 30-45 C were selected to simulate air-cooling thermal conditions. The results are compared with those obtained in the same experimental set-up with water-LiBr solutions.The control variables for the experimental study were: absorber pressure, solution Reynolds number, solution concentration and cooling water temperature. The parameters considered to assess the absorber performance were: absorber thermal load, mass absorption flux, degree of subcooling of the solution leaving the absorber, and the falling film heat transfer coefficient.The higher solubility of the multicomponent salt solution makes possible the operation of the absorber at higher salt concentration than with the conventional working fluid water-LiBr. The absorption fluxes achieved with water-(LiBr + LiI + LiNO{sub 3} + LiCl) at a concentration of 64.2 wt% are around 60 % higher than

  6. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote some relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.

  7. Flute instability in the tandem mirror with the divertor/dipole regions

    Energy Technology Data Exchange (ETDEWEB)

    Katanuma, I.; Masaki, S.; Sato, S.; Sekiya, K.; Ichimura, M.; Imai, T. [Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan)

    2011-11-15

    The numerical simulation is performed in GAMMA10 A-divertor magnetic configuration, which is a candidate of remodeled device of the GAMMA10 tandem mirror [M. Inutake et al., Phys. Rev. Lett. 55, 939 (1985)]. Both divertor and dipole regions are included in the numerical calculation, which is a new point. The electron short circuit effect along x-point, therefore, is not assumed so that it is not used the boundary condition of the electrostatic perturbations being zero at the separatrix on which the magnetic field lines pass through x-point. The simulation results reveal that the dipole field plays a role of a good magnetic field line curvature to the GAMMA10 A-divertor, and so the flute modes are stabilized without help of electron short circuit effects.

  8. [Problems with flute playing: an otological problem? Case report of a peculiar cerebellar astrocytoma].

    Science.gov (United States)

    Forton, G; Verlooy, J; Cras, P; Parizel, P; Van de Heyning, P

    1992-01-01

    A rare case of cerebellar astrocytoma presenting as a cerebellopontine angle tumour is discussed. A 35-year old woman noticed a bizarre twitching and fatigability of the left upper lip while playing the flute. There was also a mild hearing loss on the left side and she sometimes felt unsure of herself when walking. A thorough examination by means of speech audiometry, electronystagmography, ABR, CT-scan and MRI revealed a large, partly calcified mass occupying the cerebellopontine angle. Only the histological examination of the surgical specimen revealed the true nature of the tumour. The special characteristics of this tumour and the unusual clinical course are discussed. The importance of a good histological diagnosis is stressed.

  9. Low-frequency flute instabilities of a hollow cathode arc discharge - Theory and experiment.

    Science.gov (United States)

    Ilic, D. B.; Rognlien, T. D.; Self, S. A.; Crawford, F. W.

    1973-01-01

    The characteristics of two low-frequency electrostatic flute instabilities of a low-pressure hollow cathode arc discharge are reported. Mode I has azimuthal mode number m = 1, and occurs when the radial electric field is negative (directed inward), while mode II has m = - 1 and occurs when the field is positive. The radial electric field is controlled by varying the potential of a secondary anode cylinder located close to the outer discharge radius. A linear perturbation analysis, based on the two-fluid equations, is given for a low-beta, collisionless, cylindrical plasma column, immersed in a uniform axial magnetic field, having a Gaussian density profile and an arbitrary radial electric field profile. Reasonable correlation between theory and experiment is demonstrated for both modes.

  10. Severe root resorption of the upper central incisors as a consequence of playing the flute.

    Science.gov (United States)

    Seres, Laszlo; Vetro, Eva; Perenyi, Janos; Kocsis, Andras

    2017-10-01

    This study presents a case of severe root resorption of the maxillary central incisors in an 18-year-old woman who was referred for orthodontic treatment of irregular dental arches. A detailed history revealed that she used to play the block flute on an everyday basis during childhood. Against all warnings, she continued to firmly press her teeth into the mouthpiece of the instrument. Impressions of the upper central incisors were clearly visible on the instrument. Although it is well known that excessive occlusal forces can result in root resorption, to the authors' knowledge, this case involves one of the first reported occurrences of extensive root resorption that was most likely caused by playing a wind instrument during childhood. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. The flute instability as the trigger mechanism for disruption of cometary plasma tails

    Science.gov (United States)

    Ip, W.-H.; Mendis, D. A.

    1978-01-01

    The sporadic disruption of the plasma tails of some comets has recently been explained to be caused by magnetic-field-line reconnection in the cometary ionospheres due to magnetic-sector-boundary traversals. An alternative model is proposed in which the tail disruption is the end result of compression of the cometary ionosphere by high-velocity solar-wind streams, triggering the flute instability in the marginally stable tangential-discontinuity surface which separates the cometary ionosphere from the solar-wind plasma. According to the proposed model, the tail-disruption events could occur at all heliographic latitudes, whereas the Niedner-Brandt (1978) model should predict that these events are restricted to low heliographic latitudes in view of the present understanding of the sector structure of the heliosphere. Consequently, the high-latitude disruption events observed seem to present a difficulty for the latter model.

  12. Fit to play: the fitness effect on physically challenging flute repertoire.

    Science.gov (United States)

    Borkowski, Jennifer A

    2011-03-01

    This case study was done to determine whether physical fitness plays a part in performing flute repertoire. Most repertoire allows performers the choice of where to breathe. However, there exists a "brute" repertoire where breathing is prescribed by the composer, which poses physical challenges for performers. The author contrasted pieces from traditional repertoire with Heinz Holliger's (t)air(e), which requires passages of breath-holding and measured inhalations. The author was tested for cardiovascular fitness (VO2max) and corresponded these levels to pulse rates while playing at baseline and 6 months after undertaking a physical fitness program. After the exercise program, expertise with standard repertoire combined with the unmeasured variables of resonance, openness of the chest and oral cavities, embouchure size, and air speed saw little improvement with increased fitness levels. However, when air regulation is out of the performer's control, the effect of cardiovascular training brought the "brute" repertoire into the same range of difficulty as the standard repertoire.

  13. Effect of tube-support interaction on the dynamic responses of heat exchanger tubes. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1977-01-01

    Operating heat exchangers have experienced tube damages due to excessive flow-induced vibration. The relatively small inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the tube vibrational characteristics. In attempting a theoretical analysis, questions arise as to the effects of tube-baffle impacting on dynamic responses. Experiments were performed to determine the effects of tube-baffle impacting in vertical/horizontal tube orientation, and in air/water medium on the vibrational characteristics (resonant frequencies, mode shapes, and damping) and displacement response amplitudes of a seven-span tube model. The tube and support conditions were prototypic, and overall length approximately one-third that of a straight tube segment of the steam generator designed for the CRBR. The test results were compared with the analytical results based on the multispan beam with ''knife-edge'' supports.

  14. Feeding Tubes

    Science.gov (United States)

    ... feeding therapies have been exhausted. Please review product brand and method of placement carefully with your physician ... Total Parenteral Nutrition. Resources: Oley Foundation Feeding Tube Awareness Foundation Children’s Medical Nutrition Alliance APFED’s Educational Webinar ...

  15. Definition of the Face Profile in the End Section of the Teeth of the Thread Milling Cutters with Helical Flutes

    Directory of Open Access Journals (Sweden)

    O. V. Malkov

    2014-01-01

    Full Text Available An increasing thread accuracy in details of the machine-building production results from the improved design and manufacturing stages of threading tools. In modern industry, thread milling cutters gain an increasingly greater spread for thread manufacturing. Preliminary studies have shown that improving the accuracy of a cut thread is closely connected with the task of profiling the teeth of the thread milling cutters with helical flutes, and the accuracy of the solution depends on the face profile of the tool into the end section. In addition, the face profile of the tool is required to solve problems related to the calculation of strength thread milling cutters and evaluation of geometrical parameters of the teeth.The analysis of GOST 1336-77 on thread milling cutters showed that there are no geometric and structural parameters characterizing the end thread milling cutters with helical flutes. Since the standard presents thread milling cutters with a straight flutes, in which the shape of the tooth profile cutters of the second order is the same as in normal and end sections, for cutters with helical flutes it is necessary to solve the problem of conversion of normal and end sections to get the desired shape of the cutting edge.In order to assess the face profile, the end mills of high speed steel and carbide have been analyzed to show that the vast majority of the face profile of the tooth is specified in the normal section line, which is taken as an input in determining the function of the profile form for the face of the end section of the teeth thread milling cutter with helical flutes.The paper solves the problem of calculating the coordinates of the profile of the endsection of a tooth cutters with helical flutes adopted at the original tooth profile in normal section. It has been verified by modeling software CATIA V5 R17. An example illustrates finding the function form of the end section. Calculations have shown that in the end

  16. Ear Tubes

    Science.gov (United States)

    ... of the ear drum or eustachian tube, Down Syndrome, cleft palate, and barotrauma (injury to the middle ear caused by a reduction of air pressure, ... specialist) may be warranted if you or your child has experienced repeated ... fluid in the middle ear, barotrauma, or have an anatomic abnormality that ...

  17. Erosion of Fluted Cliffs on the Na Pali Coast, Kauai, Hawaiian Islands

    Science.gov (United States)

    Osborn, G.; Mohr, S.; Blay, C.

    2015-12-01

    Precipitous sea cliffs on the northwest side of Kauai, sculpted into deep bedrock gullies and sharp divides, are known as "Na Pali", Hawaiian for "the cliffs", and are commonly referred to as fluted cliffs. Rising 500 m above the coast, they constitute some of the most dramatic scenery on planet Earth and are a world famous tourist attraction. After the discovery of flank collapses on some Hawaiian volcanoes the great Na Pali escarpment was hypothesized to have been generated by a megalandslide, but bathymetric data show the shallow submarine shelf off the Na Pali coast bears no landslide deposits. It is likely that wave erosion at the base of the local thin-bedded lavas, particularly in winter, is responsible for the escarpment. Superimposed on the escarpment are the deep gullies, or grooves, and divides, which constitute drainage networks that happen to be developed on very steep slopes. Networks are poorly developed on relatively young parts of the escarpment and well developed on older parts, which feature coalescing tributaries and very deep gullies. In most cases gullies shallow going upslope, and many fade out completely just below drainage divides, just like in drainage networks developed on more gently sloping landscapes. The drainage networks show that the basalts along this coast are relatively easily eroded by runoff. Rocks easily eroded by runoff generally do not stand in 500-m-high cliffs because they are not mechanically strong enough to resist failure and mass movement. The key to development of high fluted cliffs is a mix of mechanical strength and erodibiity, a combination whose rarity explains why analogs to the Na Pali cliffs are not found outside the Hawaiian Islands. The combination here is provided by basalt which is strong where unweathered but rotten and in some case completely decomposed close to the surface, courtesy of the Hawaiian climate. Weathering must proceed downward at about the same rate as removal of mass by runoff erosion

  18. Multiple antibiotic-resistant bacteria on fluted pumpkin leaves, a herb of therapeutic value.

    Science.gov (United States)

    Igbeneghu, Oluwatoyin A; Abdu, Abdulrasheed B

    2014-06-01

    Fluted pumpkin (Telfairia occidentalis) is a minimally-processed green leafy vegetable traditionally used for its antianaemic properties in the form of leaf juice without a heating or inactivation step before consumption. The aim of the study was to assess the presence of surface microbiota on T. occidentalis leaves and also to determine the antimicrobial susceptibility of isolated organisms. Bacterial contaminants on 50 samples of T. occidentalis leaves were isolated and characterized using standard biochemical methods and the antimicrobial susceptibility of isolated organisms was determined using the antibiotic disc diffusion assay. The results obtained show that the leaves of T. occidentalis is contaminated with organisms which included Enterobacter agglomerans (25.9%), Proteus vulgaris (24.9%), Klebsiella spp. (2.6%), and Serratia liquefaciens (2.1%). Other bacterial isolates recovered in order of frequency included: Staphylococcus spp. (33.7%), Bacillus spp. (8.3%), and Pseudomonas fluorescens (2.6%). Of the 193 bacterial isolates from the leaves of T. occidentalis samples tested for antimicrobial resistance, all (100%) were found to be resistant to ampicillin, cloxacillin, augmentin, erythromycin, and tetracycline while 96% of the isolates were resistant to cephalothin. Resistance to trimethoprim (93%) and gentamicin (83%) was also observed. Approximately, 22% of the isolates were resistant to ciprofloxacin; however, only 11 (5.8%) were resistant to ofloxacin. Thus, uncooked T. occidentalis is a potential source of highly-resistant epiphytic bacteria which could be opportunistic pathogens in consumers.

  19. Optimization for energy consumption in drying section of fluting paper machine

    Directory of Open Access Journals (Sweden)

    Ghodbanan Shaaban

    2017-01-01

    Full Text Available Non-linear programming optimization method was used to optimize total steam and air consumption in the dryer section of multi-cylinder fluting paper machine. Equality constraints of the optimization model were obtained from specified process blocks considering mass and energy balance relationships in drying and heat recovery sections. Inequality constraints correspond to process parameters such as production capacity, operating conditions, and other limitations. Using the simulation, the process parameters can be optimized to improve the energy efficiency and heat recovery performance. For a corrugating machine, optimized parameters show the total steam use can be reduced by about 11% due to improvement of the heat recovery performance and optimization of the operating conditions such as inlet web dryness, evaporation rate, and exhaust air humidity, accordingly total steam consumption can be decreased from about 1.71 to 1.53 tonnes steam per tonne paper production. The humidity of the exhaust air should be kept as high as possible to optimize the energy performance and avoid condensation in the pocket dryers and hood exhaust air. So the simulation shows the supply air should be increased by about 10% to achieve optimal humidity level which was determined about 0.152 kgH2O/(kg dry air.

  20. Flute type micropores activated carbon from cotton stalk for high performance supercapacitors

    Science.gov (United States)

    Tian, Xun; Ma, Hongru; Li, Zhe; Yan, Shaocun; Ma, Lei; Yu, Feng; Wang, Gang; Guo, Xuhong; Ma, Yanqing; Wong, Chingping

    2017-08-01

    Flute type micropores activated carbon (FTMAC) has been successfully obtained from cotton stalk via KOH-chemical activation method. The synthesized carbon material exhibits an ordered pore structure with high specific surface area of 1964.46 m2 g-1 and pore volume of 1.03 m3 g-1. The assembled FTMAC-based electrode delivers a high specific capacitance of 254 F g-1 at a current density of 0.2 A g-1 in 1 M H2SO4 aqueous electrolyte. It still can maintain 221 F g-1at a current density of 10 A g-1, demonstrating a good rate capacity (87% retention), as well as long cyclic stability of 96% capacitance retention after 10000 charging and discharging cycles at current density of 1 A g-1. Moreover, the symmetric supercapacitor can deliver a high energy density of 18.14 W h kg-1 and a power density of 450.37 W kg-1 which is operated in the voltage range of 0-1.8 V.

  1. Phosphorylation of G Protein-Coupled Receptors: From the Barcode Hypothesis to the Flute Model.

    Science.gov (United States)

    Yang, Zhao; Yang, Fan; Zhang, Daolai; Liu, Zhixin; Lin, Amy; Liu, Chuan; Xiao, Peng; Yu, Xiao; Sun, Jin-Peng

    2017-09-01

    Seven transmembrane G protein-coupled receptors (GPCRs) are often phosphorylated at the C terminus and on intracellular loops in response to various extracellular stimuli. Phosphorylation of GPCRs by GPCR kinases and certain other kinases can promote the recruitment of arrestin molecules. The arrestins critically regulate GPCR functions not only by mediating receptor desensitization and internalization, but also by redirecting signaling to G protein-independent pathways via interactions with numerous downstream effector molecules. Accumulating evidence over the past decade has given rise to the phospho-barcode hypothesis, which states that ligand-specific phosphorylation patterns of a receptor direct its distinct functional outcomes. Our recent work using unnatural amino acid incorporation and fluorine-19 nuclear magnetic resonance ((19)F-NMR) spectroscopy led to the flute model, which provides preliminary insight into the receptor phospho-coding mechanism, by which receptor phosphorylation patterns are recognized by an array of phosphate-binding pockets on arrestin and are translated into distinct conformations. These selective conformations are recognized by various effector molecules downstream of arrestin. The phospho-barcoding mechanism enables arrestin to recognize a wide range of phosphorylation patterns of GPCRs, contributing to their diverse functions. Copyright © 2017 by The Author(s).

  2. The kinetics and acoustics of fingering and note transitions on the flute.

    Science.gov (United States)

    Almeida, André; Chow, Renee; Smith, John; Wolfe, Joe

    2009-09-01

    Motion of the keys was measured in a transverse flute while beginner, amateur, and professional flutists played a range of exercises. The time taken for a key to open or close was typically 10 ms when pushed by a finger or 16 ms when moved by a spring. Because the opening and closing of keys will never be exactly simultaneous, transitions between notes that involve the movement of multiple fingers can occur via several possible pathways with different intermediate fingerings. A transition is classified as "safe" if it is possible to be slurred from the initial to final note with little perceptible change in pitch or volume. Some transitions are "unsafe" and possibly involve a transient change in pitch or a decrease in volume. Players, on average, used safe transitions more frequently than unsafe transitions. Delays between the motion of the fingers were typically tens of milliseconds, with longer delays as more fingers become involved. Professionals exhibited smaller average delays between the motion of their fingers than did amateurs.

  3. Neutron tubes

    Science.gov (United States)

    Leung, Ka-Ngo; Lou, Tak Pui; Reijonen, Jani

    2008-03-11

    A neutron tube or generator is based on a RF driven plasma ion source having a quartz or other chamber surrounded by an external RF antenna. A deuterium or mixed deuterium/tritium (or even just a tritium) plasma is generated in the chamber and D or D/T (or T) ions are extracted from the plasma. A neutron generating target is positioned so that the ion beam is incident thereon and loads the target. Incident ions cause D-D or D-T (or T-T) reactions which generate neutrons. Various embodiments differ primarily in size of the chamber and position and shape of the neutron generating target. Some neutron generators are small enough for implantation in the body. The target may be at the end of a catheter-like drift tube. The target may have a tapered or conical surface to increase target surface area.

  4. Tool Wear Analysis on Five-Axis Flank Milling for Curved Shape Part – Full Flute and Ground Shank End Mill

    Directory of Open Access Journals (Sweden)

    Syahrul Azwan Sundi

    2017-01-01

    Full Text Available This paper is a study on full flute (extra-long tool and ground shank end mill wear analysis by utilizing five-axis CNC to implement flank milling strategy on curved shape part. Five-axis machining eases the user to implement variations of strategy such as flank milling. Flank milling is different from point milling. Point milling cuts materials by using the tip of the tool whereas the flank milling uses the cutting tool body to cut material. The type of cutting tool used was end mill 10 mm diameter with High Speed Steel (HSS material. One factor at a time was utilized to analyze the overall data. Feed rate and spindle speed were the two main factors that been set up equally for both full flute and ground shank end mill. At the end of this research, the qualitative analysis based on tool wear between full flute and ground shank end mill is observed. Generally, both types of cutting tools showed almost the same failure indication such as broken edge or chipped off edge, formation of pinned hole on the surface and serration formation or built-up edge (BUE on the primary flute. However, the results obtained from the enlarged images which were captured by Optical Microscope indicated that, the ground shank end mill is better than the full flute end mill.

  5. Water evaporation in vertical tubes: an analytical approach for the subcooled flow boiling region and development of a method for evaluation and sizing evaporators = Evaporación de agua en tubos verticales: análisis de la región de ebullición subenfriada y desarrollo de un método de evaluación y Dimensionado de evaporadores

    OpenAIRE

    Zambrana González, José

    2011-01-01

    The present thesis analyses in detail the process of water evaporation for convective upward flows in vertical tubes, used in industrial applications. Both, the heat transfer process and the pressure drop mechanism, are considered. However, special attention has been put on the heat transfer process in the transition from pure liquid to two-phase flow, known as subcooled flow boiling region. The empirical correlations for the heat transfer coefficient on the water side for subcooled flow boil...

  6. photomultiplier tube

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  7. photomultiplier tubes

    CERN Multimedia

    photomultiplier tubes. A device to convert light into an electric signal (the name is often abbreviated to PM). Photomultipliers are used in all detectors based on scintillating material (i.e. based on large numbers of fibres which produce scintillation light at the passage of a charged particle). A photomultiplier consists of 3 main parts: firstly, a photocathode where photons are converted into electrons by the photoelectric effect; secondly, a multiplier chain consisting of a serie of dynodes which multiply the number of electron; finally, an anode, which collects the resulting current.

  8. Efficiency of the Lung Flute for sputum induction in patients with presumed pulmonary tuberculosis.

    Science.gov (United States)

    Sakashita, Kentaro; Fujita, Akira; Takamori, Mikio; Nagai, Takayuki; Matsumoto, Tomoshige; Saito, Takefumi; Nakagawa, Taku; Ogawa, Kenji; Shigeto, Eriko; Nakatsumi, Yasuto; Goto, Hajime; Mitarai, Satoshi

    2017-08-28

    High quality sputum helps increase the sensitivity of the diagnosis of pulmonary tuberculosis. To evaluate the efficiency of the acoustic device (Lung Flute; LF) in sputum induction compared with the conventional method, hypertonic saline inhalation (HSI). In this crossover study, patients with presumed pulmonary tuberculosis submitted 3 consecutive sputa: the first sputum without induction and the second and third ones using LF and HSI. We compared the efficiency of the 2 induction methods. Sixty-four participants were eligible. Thirty-five (54.6%) patients had negative smears on the first sputum without induction. Among those patients, 25.7% and 22.9% patients were smear-positive after using LF and HSI, respectively (P = .001). The positive conversion rate was not significantly different between the methods. The first samples without induction yielded 65.7% positive cultures, whereas 71.4% and 77.1% of the samples from LF and HSI were positive, respectively (P = .284). Similar results were observed in the nucleic acid amplification test [no induction (60.0%), LF (72.0%) and HSI (60.0%); P = .341]. In 29 smear-positive patients on the first sputum without induction, we observed no significant increase in smear grade, culture yield and nucleic acid amplification test positivity with either method. LF tended to induce fewer adverse events; desaturation (3.1% vs 11.1%; P = .082) and throat pain (1.5% vs 9.5%; P = .057). LF showed significantly fewer total adverse events (15.8% vs 34.9%; P = .023). Our study showed LF had similar sputum induction efficiency to HSI with relatively fewer complications. © 2017 The Authors. The Clinical Respiratory Journal Published by John Wiley & Sons Ltd.

  9. Recruitment constraints in Singapore's fluted giant clam (Tridacna squamosa population--a dispersal model approach.

    Directory of Open Access Journals (Sweden)

    Mei Lin Neo

    Full Text Available Recruitment constraints on Singapore's dwindling fluted giant clam, Tridacna squamosa, population were studied by modelling fertilisation, larval transport, and settlement using real-time hydrodynamic forcing combined with knowledge of spawning characteristics, larval development, behaviour, and settlement cues. Larval transport was simulated using a finite-volume advection-diffusion model coupled to a three-dimensional hydrodynamic model. Three recruitment constraint hypotheses were tested: 1 there is limited connectivity between Singapore's reefs and other reefs in the region, 2 there is limited exchange within Singapore's Southern Islands, and 3 there exist low-density constraints to fertilisation efficacy (component Allee effects. Results showed that connectivity among giant clam populations was primarily determined by residual hydrodynamic flows and spawning time, with greatest chances of successful settlement occurring when spawning and subsequent larval dispersal coincided with the period of lowest residual flow. Simulations suggested poor larval transport from reefs located along the Peninsular Malaysia to Singapore, probably due to strong surface currents between the Andaman Sea and South China Sea combined with a major land barrier disrupting larval movement among reefs. The model, however, predicted offshore coral reefs to the southeast of Singapore (Bintan and Batam may represent a significant source of larvae. Larval exchange within Singapore's Southern Islands varied substantially depending on the locations of source and sink reefs as well as spawning time; but all simulations resulted in low settler densities (2.1-68.6 settled individuals per 10,000 m(2. Poor fertilisation rates predicted by the model indicate that the low density and scattered distribution of the remaining T. squamosa in Singapore are likely to significantly inhibit any natural recovery of local stocks.

  10. Explosion interaction with water in a tube

    Science.gov (United States)

    Homae, T.; Sugiyama, Y.; Wakabayashi, K.; Matsumura, T.; Nakayama, Y.

    2017-02-01

    As proposed and legislated in Japan, subsurface magazines have an explosive storage chamber, a horizontal passageway, and a vertical shaft for a vent. The authors found that a small amount of water on the floor of the storage chamber mitigated blast pressure remarkably. The mitigation mechanism has been examined more closely. To examine the effect of water, the present study assesses explosions in a transparent, square cross section, and a straight tube. A high-speed camera used to observe the tube interior. Blast pressure in and around the tube was also measured. Images obtained using the high-speed camera revealed that water inside the tube did not move after the explosion. Differences between cases of tubes without water and with water were unclear. Along with blast pressure measurements, these study results suggest that blast pressure mitigation by water occurs because of interaction between the explosion and the water near the explosion point.

  11. Monitoring gaseous CO2 and ethanol above champagne glasses: flute versus coupe, and the role of temperature.

    Directory of Open Access Journals (Sweden)

    Gérard Liger-Belair

    Full Text Available In champagne tasting, gaseous CO(2 and volatile organic compounds progressively invade the headspace above glasses, thus progressively modifying the chemical space perceived by the consumer. Simultaneous quantification of gaseous CO(2 and ethanol was monitored through micro-gas chromatography (μGC, all along the first 15 minutes following pouring, depending on whether a volume of 100 mL of champagne was served into a flute or into a coupe. The concentration of gaseous CO(2 was found to be significantly higher above the flute than above the coupe. Moreover, a recently developed gaseous CO(2 visualization technique based on infrared imaging was performed, thus confirming this tendency. The influence of champagne temperature was also tested. As could have been expected, lowering the temperature of champagne was found to decrease ethanol vapor concentrations in the headspace of a glass. Nevertheless, and quite surprisingly, this temperature decrease had no impact on the level of gaseous CO(2 found above the glass. Those results were discussed on the basis of a multiparameter model which describes fluxes of gaseous CO(2 escaping the liquid phase into the form of bubbles.

  12. Monitoring gaseous CO2 and ethanol above champagne glasses: flute versus coupe, and the role of temperature.

    Science.gov (United States)

    Liger-Belair, Gérard; Bourget, Marielle; Pron, Hervé; Polidori, Guillaume; Cilindre, Clara

    2012-01-01

    In champagne tasting, gaseous CO(2) and volatile organic compounds progressively invade the headspace above glasses, thus progressively modifying the chemical space perceived by the consumer. Simultaneous quantification of gaseous CO(2) and ethanol was monitored through micro-gas chromatography (μGC), all along the first 15 minutes following pouring, depending on whether a volume of 100 mL of champagne was served into a flute or into a coupe. The concentration of gaseous CO(2) was found to be significantly higher above the flute than above the coupe. Moreover, a recently developed gaseous CO(2) visualization technique based on infrared imaging was performed, thus confirming this tendency. The influence of champagne temperature was also tested. As could have been expected, lowering the temperature of champagne was found to decrease ethanol vapor concentrations in the headspace of a glass. Nevertheless, and quite surprisingly, this temperature decrease had no impact on the level of gaseous CO(2) found above the glass. Those results were discussed on the basis of a multiparameter model which describes fluxes of gaseous CO(2) escaping the liquid phase into the form of bubbles.

  13. Neural Tube Defects

    Science.gov (United States)

    ... vitamin, before and during pregnancy prevents most neural tube defects. Neural tube defects are usually diagnosed before the infant is ... or imaging tests. There is no cure for neural tube defects. The nerve damage and loss of function ...

  14. Nasogastric feeding tube

    Science.gov (United States)

    ... of what to do. What to Expect at Home If your child has an NG tube, try to keep your child from touching or pulling on the tube. After your nurse teaches you how to flush the tube and perform skin care around the nose, set up a daily routine for these tasks. Flushing the Tube Flushing the ...

  15. Natural vibration frequencies of horizontal tubes partially filled with liquid

    Science.gov (United States)

    Santisteban Hidalgo, Juan Andrés; Gama, Antonio Lopes; Moreira, Roger Matsumoto

    2017-11-01

    This work presents an experimental and numerical study on the flexural vibration of horizontal circular tubes partially filled with liquid. The tube is configured as a free-free beam with attention being directed to the case of small amplitudes of transverse oscillation whereas the axial movements of the tube and liquid are disregarded. At first vertical and horizontal polarizations of the flexural tube are investigated experimentally for different amounts of filling liquid. In contrast with the empty and fully-filled tubes, it is observed that natural frequencies of the vertical and horizontal polarizations are different due to asymmetry induced by the liquid layer, which acts like an added mass. Less mass of liquid is added to the tube when oscillating horizontally; as a consequence, eigenfrequencies for the horizontal polarization are found to be greater than the case of the vertically polarized tube. A simple method to calculate the natural vibration frequencies using coefficients of added mass of liquid is proposed. It is shown that the added mass coefficient increases with the liquid's level and viscosity. At last a numerical investigation of the interaction between the liquid and the tube is carried out by solving in two-dimensions the full Navier-Stokes equations via a finite volume method, with the free-surface flow being modeled with a homogeneous multiphase Eulerian-Eulerian fluid approach. Vertical and horizontal polarizations are imposed to the tube with pressure and shear stresses being determined numerically to assess the liquid's forcing onto the tube's wall. The coefficient of added mass of liquid is then estimated by the ratio between the resulting force and the acceleration imposed to the wall. A good agreement is found between experimental and numerical results, especially for the horizontally oscillating tube. It is also shown that viscosity can noticeably affect the added mass coefficients, particularly at low filling levels.

  16. Experimental approach on the collapse mechanism of CFRP composite tubes

    Science.gov (United States)

    Kim, Y. N.; Im, K. H.; Park, J. W.; Yang, I. Y.

    2001-04-01

    This study is to investigate the energy absorption characteristics of CFRP(Carbon-Fiber Reinforced Plastics) tubes on static and dynamic tests. Axial static compression tests have been carried out using the static testing machine(Shin-gang buckling testing machine) and dynamic compression tests have been utilized using an vertical crushing testing machine. When such tubes are subjected to crushing loads, the response is complex and depends on the interaction between the different mechanisms that could control the crushing process. The collapse characteristics and energy absorption have been examined for various tubes. Energy absorption of the tubes are increased as changes in the lay-up which may increase the modulus of tubes. The results have been varied significantly as a function of ply orientation and interlaminar number. In general, the stacking sequence [0/90] CFRP tubes absorbed more energy than the [15/-15] CFRP tubes.

  17. Suggestion of a New Empirical Correlation to predict Pool Boiling Heat Transfer on Tandem Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Myeong-Gie [Andong National Univ., Andong (Korea, Republic of)

    2014-10-15

    Most studies were focused on the bundles consisting of many tubes for application to a flooded evaporator. Along with the tube spacing, its location is also of interest. Many researchers have been investigated the effect of tube spacing on heat transfer for the tube bundles and the tandem tubes. The heat transfer on the upper tube of the tubes is enhanced compared with the single tube. However, the maximum heat transfer coefficient of the upper tube decreases, increases, or negligible with increasing tube pitch ( P ) in pool boiling. According to Ribatski et al. the spacing effects on the heat transfer became relevant as the tubes come closer to each other at the low heat fluxes. The effect of tube array on heat transfer enhancement was also studied for application to the flooded evaporators. Since the source of the convective flow in pool boiling is the lower heated tube, the heat transfer change due to the heat flux of the lower tube ( q{sub L}) is of interest. Kumar et al. carried an experimental study and developed a model to predict the heat transfer coefficient of individual tube in a multi-tube row and the bundle heat transfer coefficient. Ustinov et al. investigated effects of the heat flux of lower tube on pool boiling of the upper tube. They used microstructure-R134a or FC-3184 combinations and identified that the increase in the heat flux of the lower tube decreased the superheat (T{sub sat} ) of the upper tube. Summarizing the previous results it can be stated that heat transfer coefficients are highly dependent on the tube geometry and the heat flux of the lower tube. As shown in Table 1 most published studies were for the tandem tubes in a vertical column arrangement. In general, tubes are not in a vertical plane. Therefore, the present study is focused on the quantification of the combined effects of the tube pitch and the elevation angle of the tubes and the heat flux of the lower tube on pool boiling heat transfer on tandem tubes. To the present

  18. Arrested Bubble Rise in a Narrow Tube

    Science.gov (United States)

    Lamstaes, Catherine; Eggers, Jens

    2017-05-01

    If a long air bubble is placed inside a vertical tube closed at the top it can rise by displacing the fluid above it. However, Bretherton found that if the tube radius, R, is smaller than a critical value Rc=0.918 ℓ _c, where ℓ _c=√{γ /ρ g} is the capillary length, there is no solution corresponding to steady rise. Experimentally, the bubble rise appears to have stopped altogether. Here we explain this observation by studying the unsteady bubble motion for Rmotion.

  19. Application of the Critical Heat Flux Look-Up Table to Large Diameter Tubes

    Directory of Open Access Journals (Sweden)

    M. El Nakla

    2013-01-01

    Full Text Available The critical heat flux look-up table was applied to a large diameter tube, namely 67 mm inside diameter tube, to predict the occurrence of the phenomenon for both vertical and horizontal uniformly heated tubes. Water was considered as coolant. For the vertical tube, a diameter correction factor was directly applied to the 1995 critical heat flux look-up table. To predict the occurrence of critical heat flux in horizontal tube, an extra correction factor to account for flow stratification was applied. Both derived tables were used to predict the effect of high heat flux and tube blockage on critical heat flux occurrence in boiler tubes. Moreover, the horizontal tube look-up table was used to predict the safety limits of the operation of boiler for 50% allowable heat flux.

  20. Vertical motion of particles in vibration-induced granular capillarity

    Directory of Open Access Journals (Sweden)

    Fan Fengxian

    2017-01-01

    Full Text Available When a narrow tube inserted into a static container filled with particles is subjected to vertical vibration, the particles rise in the tube, much resembling the ascending motion of a liquid column in a capillary tube. To gain insights on the particle dynamics dictating this phenomenon – which we term granular capillarity – we numerically investigate the system using the Discrete Element Method (DEM. We reproduce the dynamical process of the granular capillarity and analyze the vertical motion of the individual particles in the tube, as well as the average vertical velocities of the particles. Our simulations show that the height of the granular column fluctuates in a periodic or period-doubling manner as the tube vibrates, until a steady-state (capillary height is reached. Moreover, our results for the average vertical velocity of the particles in the tube at different radial positions suggest that granular convection is one major factor underlying the particle-based dynamics that lead to the granular capillarity phenomenon.

  1. Acquired vertical accommodative vergence.

    Science.gov (United States)

    Klein-Scharff, Ulrike; Kommerell, Guntram; Lagrèze, Wolf A

    2008-03-08

    Vertical accommodative vergence is an unusual synkinesis in which vertical vergence is modulated together with accommodation. It results from a supranuclear miswiring of the network normally conveying accommodative convergence. So far, it is unknown whether this condition is congenital or acquired. We identified an otherwise healthy girl who gradually developed vertical accommodative vergence between five to 13 years of age. Change of accommodation by 3 diopters induced a vertical vergence of 10 degrees. This observation proves that the miswiring responsible for vertical accommodative vergence must not necessarily be congenital, but can be acquired. The cause and the mechanism leading to vertical accommodative vergence are yet unknown.

  2. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  3. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia ... of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ...

  4. NEI You Tube Videos: Amblyopia

    Science.gov (United States)

    ... YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia ... of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia ...

  5. Experimental determination of the forced convective boiling heat transfer coefficients of R407C in fluted-tubes / Philip Wouter de Vos

    OpenAIRE

    De Vos, Wouter Philip

    2006-01-01

    Due to the phase-out of all refrigerants with ozone depletion potential, a large void is left in the refrigeration market. This void was caused due to a lack of new, ozone friendly, pure refrigerants with similar thermodynamic properties to those of the banned refrigerants. As a result mixtures of refrigerants are used to create replacement refrigerants. These new mixtures have to be experimentally evaluated to derive correlations for the prediction of the heat transfer coeffic...

  6. Time-domain simulation of flute-like instruments: comparison of jet-drive and discrete-vortex models.

    Science.gov (United States)

    Auvray, Roman; Ernoult, Augustin; Fabre, Benoît; Lagrée, Pierre-Yves

    2014-07-01

    This paper presents two models of sound production in flute-like instruments that allow time-domain simulations. The models are based on different descriptions of the jet flow within the window of the instrument. The jet-drive model depicts the jet by its transverse perturbation that interacts with the labium to produce sound. The discrete-vortex model depicts the jet as two independent shear layers along which vortices are convected and interact with the acoustic field within the window. The limit of validity between both models is usually discussed according to the aspect ratio of the jet W/h, with W the window length and h the flue channel height. The present simulations, compared with experimental data gathered on a recorder, allow to extend the aspect ratio criterion to the notion of dynamic aspect ratio defined as λ/h where λ is the hydrodynamic wavelength that now accounts for geometrical properties, such as W/h, as well as for dynamic properties, such as the Strouhal number. The two models are found to be applicable over neighboring values of geometry and blowing pressure.

  7. Sub-Alfvénic reduced full-f Kinetic MHD equations to study flute like instabilities

    Science.gov (United States)

    Sengupta, W.; Hassam, A.; Antonsen, T. M., Jr.

    2016-10-01

    We develop a set of reduced sub-Alfvénic fluid as well as kinetic MHD equations which are suitable for studying flute like instabilities in MHD ordering. The full-f kinetic equations are obtained by reducing Kulsrud's complete set of kinetic MHD system and includes trapped ion dynamics in a toroidal geometry. The nonlinear equations show the presence of Mercier modes, electromagnetic effects, GAMs and Rosenbluth-Hinton zero frequency zonal flows. Linear stability based on our equations shall be compared to the well known Kruskal-Oberman Kinetic MHD stability criteria. In the supersonic limit, for large q, our system can be shown to be equivalent to CGL double adiabatic theory. In the marginal stability limit, we shall discuss trapped particle stabilization of interchange modes. Comparison will also be made to the sub-Alfvénic reduced MHD fluid equations in a large aspect ratio tokamak. We shall show that the trapped particle effects in kinetic theory can be treated as a boundary layer of width the square root of the inverse aspect ratio in phase space. Work supported by DOE.

  8. Pulse Tube Refrigerator

    Science.gov (United States)

    Matsubara, Yoichi

    The pulse tube refrigerator is one of the regenerative cycle refrigerators such as Stirling cycle or Gifford-McMahon cycle which gives the cooling temperature below 150 K down to liquid helium temperature. In 1963, W. E. Gifford invented a simple refrigeration cycle which is composed of compressor, regenerator and simple tube named as pulse tube which gives a similar function of the expander in Stirling or Gifford-McMahon cycle. The thermodynamically performance of this pulse tube refrigerator is inferior to that of other regenerative cycles. In 1984, however, Mikulin and coworkers made a significant advance in pulse tube configuration called as orifice pulse tube. After this, several modifications of the pulse tube hot end configuration have been developed. With those modifications, the thermodynamic performance of the pulse tube refrigerator became the same order to that of Stirling and Gifford-McMahon refrigerator. This article reviews the brief history of the pulse tube refrigerator development in the view point of its thermodynamically efficiency. Simplified theories of the energy flow in the pulse tube have also been described.

  9. The equilibrium structure of thin magnetic flux tubes. II. [in sun and late stars

    Science.gov (United States)

    Kalkofen, W.; Rosner, R.; Ferrari, A.; Massaglia, S.

    1986-01-01

    The thermal structure of the medium inside thin, vertical magnetic flux tubes embedded in a given external atmosphere is investigated, assuming cylindrical symmetry and a depth-independent plasma beta. The variation with tube radius of the temperature on the tube axis is computed and the temperature on the tube wall is estimated. The temperature variation across the flux tube is found to be due to the depth variation of the intensity and to the density stratification of the atmosphere. Since the temperature difference between the axis and the wall is small in thin flux tubes (of the order of 10 percent), the horizontal temperature gradient may often be neglected and the temperature in a tube of given radius may be described by a single function of depth. Thus, a more detailed numerical treatment of the radiative transfer within thin flux tubes can be substantially simplified by neglecting horizontal temperature differences within the flux tube proper.

  10. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube......’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  11. Attenuation of low frequency duct noise by a flute-like silencer

    Science.gov (United States)

    Huang, Lixi

    2009-09-01

    A broadband, duct noise reflection mechanism is introduced in this theoretical study. It consists of side-branch cavities filled with a light gas, e.g. helium, and covered by impervious, tensioned membranes as two apertures, one at the inlet and another at the exit. Incident waves are scattered by the membranes into two passages, one through the central duct and another through the cavity bypass. Due to the faster speed of sound in the bypass, a Herschel-Quincke tube resonance appears and gives a peak in the transmission loss spectrum. Another resonance occurs when the frequency of the incident sound coincides with the vibroacoustic frequency determined by the membrane tension and inertia contributions from the membrane and the fluid media. With appropriate tensile stress, the trough between the two spectral peaks can be elevated to a desirable high level, e.g. 10 dB, and the crucial factor is identified as the low density of the cavity gas filling. The broadband sound reflection performance is comparable with and even exceeds that of the drum-like silencer [L. Huang, Parametric study of a drum-like silencer, Journal of Sound and Vibration 269 (2004) 467-488] with the same cavity geometry, but the current mechanism requires a low tensile stress which is much easier to implement in practice.

  12. Retrograde Gastrojejunostomy Tube Migration

    Directory of Open Access Journals (Sweden)

    Adeleke Adesina

    2014-01-01

    Full Text Available Percutaneous enteral feeding tubes are placed about 250,000 times each year in the United States. Although they are relatively safe, their placement may be complicated by perforation, infection, bleeding, vomiting, dislodgment, and obstruction. There have been numerous reports of antegrade migration of gastrojejunostomy (G-J tubes. We report a case of G-J tube regurgitation following protracted vomiting and discuss the management of this very rare entity.

  13. Vertical axis wind turbines

    Science.gov (United States)

    Krivcov, Vladimir [Miass, RU; Krivospitski, Vladimir [Miass, RU; Maksimov, Vasili [Miass, RU; Halstead, Richard [Rohnert Park, CA; Grahov, Jurij [Miass, RU

    2011-03-08

    A vertical axis wind turbine is described. The wind turbine can include a top ring, a middle ring and a lower ring, wherein a plurality of vertical airfoils are disposed between the rings. For example, three vertical airfoils can be attached between the upper ring and the middle ring. In addition, three more vertical airfoils can be attached between the lower ring and the middle ring. When wind contacts the vertically arranged airfoils the rings begin to spin. By connecting the rings to a center pole which spins an alternator, electricity can be generated from wind.

  14. PROSPECTS OF ESTABLISHING EARTHQUAKE RESISTANT BUILDINGS FROM TUBE CONCRETE CONSTRUCTIONS

    Directory of Open Access Journals (Sweden)

    Abdujafar I. Akaev

    2017-01-01

    Full Text Available Abstract. Objectives The aim of the research is to find optimal design solutions for the erection of buildings that will ensure their reliability and durability, compliance with environmental requirements, fire resistance and earthquake resistance. In this regard, the task is to determine the advantages and prospects of erecting earthquake resistant buildings from tube concrete constructions, since they are distinct in constructive, technological and economic efficiency when are used as vertical load-bearing struts of high-rise buildings. Method The technique for calculating the strength of normal sections of eccentrically-compressed tube concrete elements uses a nonlinear deformation model, taking into account the joint operation of the steel shell and the concrete core under the conditions of triaxial compression. Results In the article the review of the newest world experience of using tube concrete as vertical load-bearing structures for public facilities from the standpoint of earthquake resistant construction is given. The international practices of public facility construction ranging in height from 100 to 600 m with the use of tube concrete technology, including regions with dangerous natural and man-made conditions, have been studied. The structural, operational and technological advantages and disadvantages of tube concrete technology are analysed. Methods for calculating the strength of concrete tube elements in the case of central compression are considered: according to the so-called deformation theory, the state of total destruction of both concrete and tube fluidity attained at maximum pressure are indicated by the beginning of "tube flow on the longitudinal axis". The advantages and disadvantages of both methods are shown. Factors constraining the introduction and wider application of tube concrete constructions in Russia are considered. Conclusion While the advantages of concrete tube constructions in their extensive

  15. Heated Tube Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Heated Tube Facility at NASA GRC investigates cooling issues by simulating conditions characteristic of rocket engine thrust chambers and high speed airbreathing...

  16. Construction of preheaters with horizontal tubes

    Energy Technology Data Exchange (ETDEWEB)

    Goetze

    1944-09-27

    This report involved construction of preheaters for distillation and cracking plants in the oil industry, particularly in America. The use of heat transmission by radiation was also a consideration here. The recycling of waste gases occurred, but was not the rule. A convection section was often built next to the radiation section, in which the discharge gases were used for heating the incoming product. The general arrangement of the preheaters was discussed. The first form was a rectangular box with fireproof lining with tubes arranged in a single row along the outer walls and sometimes in a double row on the ceiling. It consisted of smooth and finned tubes. From the simple form a double preheater was developed that allowed one or two common discharge flues to provide as large a heating surface as possible within a reasonable space. Other items discussed were recycling of waste gases, reasons for the choice of horizontal preheaters with radiation heating, the use of vertical tubes in the U.S.A. and elsewhere in the oil industry, details of horizontal preheater tubes, end closures, material, suspension, protection against overloading by radiation, circulation heating, burners, use of horizontal radiation preheaters in hydrogenation in the U.S.A., rebuilding I. G. preheaters, construction, tube supports, and masonry. A list of references on cracking, preheaters, heat transmission, and alloyed steels was given.

  17. Steam generator tube failures

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  18. COMPLIANCE OF KÖHLER OP:33 NO I-II-III ETUDE BOOKS THAT ARE USED IN HIGH SCHOOLS OF FINE ARTS WITH FLUTE CONCERTOS

    Directory of Open Access Journals (Sweden)

    Yucan EKE

    2015-09-01

    Full Text Available This research is done for attesting the compliance of the etudes in German composer Ernesto Köhler’s op:33 no I-II-III books that are used in high schools of fine arts, with ability to play the flute concertos in high schools of fine arts 12 grade program, in terms of the knowledge – skills and musical functions they cover and also for contributing to learning by matching the etudes and works which are relevant. Etudes and the chosen concertos are analyzed and separated into templates in terms of melody, rhythm and tone for this research. Opinions are taken from the flute lesson instructors of various universities of Turkey to define the melody, technique and rhythm patterns. As a result of the analysis, Köhler op: 33, Book I, Etudes: 2,3,6,7,8,9,10,11,12; Köhler op: 33, Book II, Etudes:1,3,4,5,8,9,10,11; Köhler op: 33, Book III, Etudes: 1, 2, 4, 5, 6, 8; It is determined that the etudes given above in Köhler books are qualified enough to be preparative and instructive for the ability of playing the flute concertos. Some suggestions are given about which etude(s is instructive for which concerto and what kind of benefits could be gained, by this study. Based on the observed results, various suggestions are made about defining and studying the etudes which meet the technical, rhythmic and melodic features of the target concerto.

  19. Pyrotechnic Tubing Connector

    Science.gov (United States)

    Graves, Thomas J.; Yang, Robert A.

    1988-01-01

    Tool forms mechanical seal at joint without levers or hydraulic apparatus. Proposed tool intended for use in outer space used on Earth by heavily garbed workers to join tubing in difficult environments. Called Pyrotool, used with Lokring (or equivalent) fittings. Piston slides in cylinder when pushed by gas from detonating pyrotechnic charge. Impulse of piston compresses fittings, sealing around butting ends of tubes.

  20. Neural Tube Defects

    Science.gov (United States)

    ... pregnancies each year in the United States. A baby’s neural tube normally develops into the brain and spinal cord. ... fluid in the brain. This is called hydrocephalus. Babies with this condition are treated with surgery to insert a tube (called a shunt) into the brain. The shunt ...

  1. Molybdenum Tube Characterization report

    Energy Technology Data Exchange (ETDEWEB)

    Beaux II, Miles Frank [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Usov, Igor Olegovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-07

    Chemical vapor deposition (CVD) techniques have been utilized to produce free-standing molybdenum tubes with the end goal of nuclear fuel clad applications. In order to produce tubes with properties desirable for this application, deposition rates were lowered requiring long deposition durations on the order of 50 hours. Standard CVD methods as well as fluidized-bed CVD (FBCVD) methods were applied towards these objectives. Characterization of the tubes produced in this manner revealed material suitable for fuel clad applications, but lacking necessary uniformity across the length of the tubes. The production of freestanding Mo tubes that possess the desired properties across their entire length represents an engineering challenge that can be overcome in a next iteration of the deposition system.

  2. Isolated Fallopian Tube Torsion

    Directory of Open Access Journals (Sweden)

    S. Kardakis

    2013-01-01

    Full Text Available Isolated torsion of the Fallopian tube is a rare gynecological cause of acute lower abdominal pain, and diagnosis is difficult. There are no pathognomonic symptoms; clinical, imaging, or laboratory findings. A preoperative ultrasound showing tubular adnexal masses of heterogeneous echogenicity with cystic component is often present. Diagnosis can rarely be made before operation, and laparoscopy is necessary to establish the diagnosis. Unfortunately, surgery often is performed too late for tube conservation. Isolated Fallopian tube torsion should be suspected in case of acute pelvic pain, and prompt intervention is necessary.

  3. Determination and evaluation of effective criteria to location selection the optimal for establishing fluting paper mills from agricultural residues of Mazandaran province

    Directory of Open Access Journals (Sweden)

    Abdollah barimani

    2013-11-01

    Full Text Available Location selection for factory competitiveness in the market place plays an important role and should be chosen so that will leads achievement of the strategic advantages compared with other competitors. The objective of this study was determination of the effective criteria for decision making to select the most suitable location for establishing a fluting paper mills from agricultural residues. For this purpose, effective criteria were divided into five major groups: Material and Product, Facilities and limitations of regional (infrastructure, Technical and Human, Economical, Rules & Regulations as well as 33 sub-criteria, after preliminary investigation, preparatory observation, and an interview with some of the paper producers and relevant experts. A hierarchy was designed based on five major groups of criteria and then the priority rates of obtained criteria and sub-criteria were determined by Analytical Hierarchy Process (AHP after compiling expert's opinions via questionnaire. Results have shown that among 33 determined effective criteria in location selection of fluting paper mills from agricultural residues , the sub-criteria of Supply residual amount, Ensure the supply of residual, Cost purchasing of raw material, Cost of transporting raw material have the highest priorities, respectively

  4. Tracheostomy tube - eating

    Science.gov (United States)

    Trach - eating ... take your first bites. Certain factors may make eating or swallowing harder, such as: Changes in the ... easier to swallow. Suction the tracheostomy tube before eating. This will keep you from coughing while eating, ...

  5. Bull Moose Tube Company

    Science.gov (United States)

    The EPA is providing notice of a proposed Administrative Penalty Assessment against the Bull Moose Tube Company, a business located at 1819 Clarkson Road, Chesterfield, MO, 63017, for alleged violations at the facility located at 406 East Industrial Drive,

  6. Tube-Forming Assays.

    Science.gov (United States)

    Brown, Ryan M; Meah, Christopher J; Heath, Victoria L; Styles, Iain B; Bicknell, Roy

    2016-01-01

    Angiogenesis involves the generation of new blood vessels from the existing vasculature and is dependent on many growth factors and signaling events. In vivo angiogenesis is dynamic and complex, meaning assays are commonly utilized to explore specific targets for research into this area. Tube-forming assays offer an excellent overview of the molecular processes in angiogenesis. The Matrigel tube forming assay is a simple-to-implement but powerful tool for identifying biomolecules involved in angiogenesis. A detailed experimental protocol on the implementation of the assay is described in conjunction with an in-depth review of methods that can be applied to the analysis of the tube formation. In addition, an ImageJ plug-in is presented which allows automatic quantification of tube images reducing analysis times while removing user bias and subjectivity.

  7. Tube Alinement for Machining

    Science.gov (United States)

    Garcia, J.

    1984-01-01

    Tool with stepped shoulders alines tubes for machining in preparation for welding. Alinement with machine tool axis accurate to within 5 mils (0.13mm) and completed much faster than visual setup by machinist.

  8. Power vacuum tubes handbook

    CERN Document Server

    Whitaker, Jerry

    2012-01-01

    Providing examples of applications, Power Vacuum Tubes Handbook, Third Edition examines the underlying technology of each type of power vacuum tube device in common use today. The author presents basic principles, reports on new development efforts, and discusses implementation and maintenance considerations. Supporting mathematical equations and extensive technical illustrations and schematic diagrams help readers understand the material. Translate Principles into Specific Applications This one-stop reference is a hands-on guide for engineering personnel involved in the design, specification,

  9. Aeronautical tubes and pipes

    Science.gov (United States)

    Beauclair, N.

    1984-12-01

    The main and subcomponent French suppliers of aircraft tubes and pipes are discussed, and the state of the industry is analyzed. Quality control is essential for tubes with regard to their i.d. and metallurgical compositions. French regulations do not allow welded seam tubes in hydraulic circuits unless no other form is available, and then rustproofed steel must be installed. The actual low level of orders for any run of tubes dictates that the product is only one of several among the manufacturers' line. Automation, both in NDT and quality control, assures that the tubes meet specifications. A total of 10 French companies participate in the industry, serving both civil and military needs, with some companies specializing only in titanium, steel, or aluminum materials. Concerns wishing to enter the market must upgrade their equipment to meet the higher aeronautical specifications and be prepared to furnish tubes and pipes that serve both functional and structural purposes simultaneously. Additionally, pipe-bending machines must also perform to tight specifications. Pipes can range from 0.2 mm exterior diameter to 40 mm, with wall thicknesses from 0.02 mm to 3 mm. A chart containing a list of manufacturers and their respective specifications and characteristics is presented, and a downtrend in production with reduction of personnel is noted.

  10. Spherical tube hypersurfaces

    CERN Document Server

    Isaev, Alexander

    2011-01-01

    We examine Levi non-degenerate tube hypersurfaces in complex linear space which are "spherical," that is, locally CR-equivalent to the real hyperquadric. Spherical hypersurfaces are characterized by the condition of the vanishing of the CR-curvature form, so such hypersurfaces are flat from the CR-geometric viewpoint. On the other hand, such hypersurfaces are also of interest from the point of view of affine geometry. Thus our treatment of spherical tube hypersurfaces in this book is two-fold: CR-geometric and affine-geometric. As the book shows, spherical tube hypersurfaces possess remarkable properties. For example, every such hypersurface is real-analytic and extends to a closed real-analytic spherical tube hypersurface in complex space. One of our main goals is to provide an explicit affine classification of closed spherical tube hypersurfaces whenever possible. In this book we offer a comprehensive exposition of the theory of spherical tube hypersurfaces, starting with the idea proposed in the pioneering...

  11. Tapered fluted titanium stems in the management of Vancouver B2 and B3 periprosthetic femoral fractures.

    Science.gov (United States)

    Munro, Jacob T; Garbuz, Donald S; Masri, Bassam A; Duncan, Clive P

    2014-02-01

    Surgeons have several implant choices when managing Vancouver B2 and B3 periprosthetic fractures about the hip. Few long-term studies have reported outcomes for tapered fluted titanium stems. We determined (1) survival, with femoral revision as the end point, of distal taper stems in the treatment of Vancouver B2 and B3 periprosthetic fractures at our institution, (2) radiographic outcomes, and (3) quality of life and hip function after revision. Of the 200 patients with Vancouver B2 or B3 periprosthetic fractures treated with femoral revision between February 2000 and February 2010, 55 (38 B2, 17 B3) were treated with modular tapered titanium stems. Of the surviving 47 patients, one was lost to followup, leaving 46 (30 B2, 16 B3) available for review at a mean of 54 months (range, 24-143 months). Initial indications for using these implants were treatment of periprosthetic fractures where less than 4 cm of diaphyseal fit was available, but this evolved during the study period to all fractures unless no diaphysis remained, in which case complex revision techniques were used. Radiographs were assessed to establish fracture healing, stem subsidence, and bone stock restoration. Quality of life and hip function were assessed using WOMAC, Oxford, SF-12, UCLA activity level, and satisfaction scores. Two femoral stems were revised: one subsided and was revised at 12 months; the other had deep infection and underwent two-stage revision at 49 months. Radiographic review showed one nonunion, with maintenance or improvement of bone stock in 89% of patients. Subsidence occurred in 24%. Mean Oxford score was 76 of 100, WOMAC function and pain scores were 75 and 82 of 100, satisfaction score was 91 of 100, and SF-12 mental and physical scores were 53 and 40 of 100. We report encouraging short-term results in terms of survival of distal taper stems in the treatment of B2 and B3 periprosthetic fractures. Although subsidence was frequent, most migrated less than 3 mm without

  12. The Comparison of the Effect of Block Flute Accompanied Song Teaching with Multi-Sound Notation and Vocalization Program Accompanied Song Teaching on the Success of Students' Song Learning Behavior

    Science.gov (United States)

    Saktanli, S. Cem

    2011-01-01

    This experimental study was done to see if using computer supported notation and vocalization program for teaching songs instead of using block flute accompanied song teaching has any significant effect on students' singing behavior. The study group is composed of the 5th, 6th and 7th graders of 2008-2009 educational term in T.O.K.I. Yahya Kemal…

  13. Development of Empirical Correlation to Calculate Pool Boiling Heat Transfer of Tandem Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Myeong-Gie [Andong National University, Andong (Korea, Republic of)

    2015-10-15

    The heat exchanging tubes are in vertical alignment. For the cases, the upper tube is affected by the lower tube. Since heat transfer is closely related to the conditions of tube surface, bundle geometry, and liquid, lots of studies have been carried out for the several decades to investigate the combined effects of those factors on pool boiling heat transfer. One of the most important parameters in the analysis of a tube array is the pitch ( P ) between tubes. Many researchers have been investigated its effect on heat transfer enhancement for the tube bundles and the tandem tubes. The effect of a tube array on heat transfer enhancement was also studied for application to the flooded evaporators. Cornwell and Schuller studied the sliding bubbles by high speed photography to account the enhancement of heat transfer observed at the upper tubes of a bundle. The study by Memory et al. shows the effects of the enhanced surface and oil adds to the heat transfer of tube bundles. They identified that, for the structured and porous bundles, oil addition leads to a steady decrease in performance. The flow boiling of n-pentane across a horizontal tube bundle was investigated experimentally by Roser et al. They identified that convective evaporation played a significant part of the total heat transfer. The fouling of the tube bundle under pool boiling was also studied by Malayeri et al. They identified that the mechanisms of fouling on the middle and top heater substantially differ from those at the bottom heater.

  14. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home > NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  15. Gastrostomy feeding tube - pump - child

    Science.gov (United States)

    ... tube feeding; PEG tube care; Feeding - gastrostomy tube - pump; G-tube - pump; Gastrostomy button - pump; Bard Button - pump; MIC-KEY - pump ... Gather supplies: Feeding pump (electronic or battery powered) Feeding ... pump (includes a feeding bag, drip chamber, roller clamp, ...

  16. Vertical atlantoaxial dislocation

    OpenAIRE

    Ramaré, S.; Lazennec, J. Y.; Camelot, C.; Saillant, G.; Hansen, S.; Trabelsi, R.

    1999-01-01

    An unusual case of vertical atlantoaxial dislocation without medulla oblongata or spinal cord injury is reported. The pathogenic process suggested occipito-axial dislocation. The case was treated surgically with excellent results on mobility and pain.

  17. Coordination in vertical jumping

    NARCIS (Netherlands)

    Bobbert, Maarten F.; van Ingen Schenau, Gerrit Jan

    1988-01-01

    The present study was designed to investigate for vertical jumping the relationships between muscle actions, movement pattern and jumping achievement. Ten skilled jumpers performed jumps with preparatory countermovement. Ground reaction forces and cinematographic data were recorded. In addition,

  18. Hybrid vertical cavity laser

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2010-01-01

    A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide.......A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide....

  19. Composition of vertical gardens

    OpenAIRE

    Sandeva, Vaska; Despot, Katerina

    2013-01-01

    Vertical gardens are fully functional gardens in areas where there is less oxygen and space, ideal for residential and urban cities where there is no vegetation; occupy a special place in interiors furniture. The gardens occupy an important aesthetic problem. Aesthetic task in vertical gardens can be achieved by forming sectors of identification in the urban landscape through the choice of a particular plant spatial composition and composition, to create comfort and representation in commu...

  20. Categorising YouTube

    Directory of Open Access Journals (Sweden)

    Thomas Mosebo Simonsen

    2011-09-01

    Full Text Available This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC of YouTube. The article investigates the construction of navigationprocesses on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within the interacting relationship of new and old genres are discussed. It is argued that the utility of a conventional categorical system is primarily of analytical and theoretical interest rather than as a practical instrument.

  1. Geiger-Muller tubes

    Energy Technology Data Exchange (ETDEWEB)

    Gair, S.A.; Copleston, R.E.

    1991-01-16

    A Geiger-Muller tube designed for use in an environment (for example, mounted on a rock drill) where subjected to mechanical shock and vibration has a tensioned anode wire secured by welding to securement members between first and second mounts at opposite ends of the tube envelope. The wire tension is adjusted to a high value with a screwable-adjustment means which is locked eg. by a spot-weld or by a locking nut, in the adjusted position, so that the natural frequency of the vibration of the tensioned wire does not resonate with (and may be much higher than) the frequencies to which the tube is subjected in use. The wire frequency is typically in excess of 400Hz and even 500Hz. The adjustment means may be included in the mount via which the envelope is evacuated and back-filled with the ionizible gas, and a gas-tight seal can be provided around this part of the mount, for example by sealing off the gas pump tube. However the adjustment means may be designed into another part of the tube, for example using telescopic parts of the envelope whose sliding junction is made gas tight with a flexible seal. (author).

  2. Helical Motion of Magnetic Flux Tubes in the Solar Atmosphere

    Science.gov (United States)

    Zaqarashvili, T. V.; Skhirtladze, N.

    2008-08-01

    Photospheric granulation may excite transverse kink pulses in anchored vertical magnetic flux tubes. The pulses propagate upward along the tubes with the kink speed, while oscillating wakes are formed behind the wave front in a stratified atmosphere. The wakes oscillate at the kink cutoff frequency of stratified medium and gradually decay in time. When two or more consecutive kink pulses with different polarizations propagate in the same thin tube, then the wakes corresponding to different pulses may be superimposed. The superposition sets up helical motions of magnetic flux tubes in the photosphere/chromosphere as seen in recent Hinode movies. The energy carried by the pulses is enough to heat the solar chromosphere/corona and accelerate the solar wind.

  3. Experimental Study of Falling Water Limitation under a Counter-Current Flow in a Vertical Rectangular Channel : 1st Report, Effect of Flow Channel Configuration and Introduction of CCFL Correlation

    National Research Council Canada - National Science Library

    SUDO, Yukio; USUI, Tohru; KAMINAGA, Masanori

    1991-01-01

    Counter-current-flow limitation (CCFL) experiments were carried out for both vertical rectangular channels and vertical circular tubes varying in size and in configuration of their cross sections to clarify CCFL characteristics...

  4. A New Resonance Tube

    Science.gov (United States)

    Bates, Alan

    2017-01-01

    The measurement of the speed of sound in air with the resonance tube is a popular experiment that often yields accurate results. One approach is to hold a vibrating tuning fork over an air column that is partially immersed in water. The column is raised and lowered in the water until the generated standing wave produces resonance: this occurs at…

  5. Cladding tube manufacturing technology

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, R. [Kraftwerk Union AG, Mulheim (Germany); Jeong, Y.H.; Baek, B.J.; Kim, K.H.; Kim, S.J.; Choi, B.K.; Kim, J.M. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-04-01

    This report gives an overview of the manufacturing routine of PWR cladding tubes. The routine essentially consists of a series of deformation and annealing processes which are necessary to transform the ingot geometry to tube dimensions. By changing shape, microstructure and structure-related properties are altered simultaneously. First, a short overview of the basics of that part of deformation geometry is given which is related to tube reducing operations. Then those processes of the manufacturing routine which change the microstructure are depicted, and the influence of certain process parameters on microstructure and material properties are shown. The influence of the resulting microstructure on material properties is not discussed in detail, since it is described in my previous report 'Alloy Development for High Burnup Cladding.' Because of their paramount importance still up to now, and because manufacturing data and their influence on properties for other alloys are not so well established or published, the descriptions are mostly related to Zry4 tube manufacturing, and are only in short for other alloys. (author). 9 refs., 46 figs.

  6. Jejunostomy feeding tube

    Science.gov (United States)

    ... skin for redness, odor, pain, puss, or swelling. Make sure the stitches are still in place. Use the clean towel or Q-tip to clean the skin around the J-tube 1 to 3 times a day with mild soap and water. Try to remove any drainage or crusting on ...

  7. Drift tubes of Linac 2

    CERN Multimedia

    Photographic Service

    1977-01-01

    Being redied for installation, those at the right are for tank 1, those on the left for tank 2. Contrary to Linac 1, which had drift-tubes supported on stems, here the tubes are suspended, for better mechanical stability.

  8. Diel vertical migrat..

    African Journals Online (AJOL)

    2002-01-24

    Jan 24, 2002 ... crustacean zooplankton but also in a Wide array of different marine zooplankton groups. (Russell 1927, McLaren 1963). Thus there is no doubt that ..... cooperation during field work and for their fruitful discussion on the draft manuscript. REFERENCES. Bayly lAE 1986 Aspects of diel vertical migration in ...

  9. Vertical market participation

    DEFF Research Database (Denmark)

    Schrader, Alexander; Martin, Stephen

    1998-01-01

    Firms that operate at both levels of vertically related Cournot oligopolies will purchase some input supplies from independent rivals, even though they can produce the good at a lower cost, driving up input price for nonintegrated firms at the final good level. Foreclosure, which avoids this stra...... this strategic behavior, yields better market performance than Cournot beliefs...

  10. Hunting Voronoi vertices

    NARCIS (Netherlands)

    Ferrucci, V.; Overmars, Mark; Rao, A.; Vleugels, J.

    1994-01-01

    Given three objects in the plane, a Voronoi vertex is a point that is equidistant simultaneously from each. In this paper, we consider the problem of computing Voronoi vertices for planar objects of xed but possibly unknown shape; we only require the ability to query the closest point on an object

  11. Vertical shaft windmill

    Science.gov (United States)

    Grana, D. C.; Inge, S. V., Jr. (Inventor)

    1983-01-01

    A vertical shaft has several equally spaced blades mounted. Each blade consists of an inboard section and an outboard section skew hinged to the inboard section. The inboard sections automatically adjust their positions with respect to the fixed inboard sections with changes in velocity of the wind. This windmill design automatically governs the maximum rotational speed of shaft.

  12. Protective Vertical Shelters.

    Science.gov (United States)

    1983-06-29

    strengths of 27.6 MPa and 41.1 MPa, respectively. The mix proportions are reported in Table 1. Type II high - early portland cement was used in the...of a shelter transition section, thickness-to-radius ratio (t/r) of the shelter tube section, and concrete strength ) on shelter response. In addition...kilograms Water , in kilograms 189 155 Pozzoligh, in milliliters 1183 1124 Entrained air, as a percentage 3 3 Slump, in millimeters 127 127 Water / cement

  13. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... NEI YouTube Videos: Amblyopia NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma ...

  14. Enteral Tube Feeding and Pneumonia

    Science.gov (United States)

    Gray, David Sheridan; Kimmel, David

    2006-01-01

    To determine the effects of enteral tube feeding on the incidence of pneumonia, we performed a retrospective review of all clients at our institution who had gastrostomy or jejunostomy tubes placed over a 10-year period. Ninety-three subjects had a history of pneumonia before feeding tube insertion. Eighty had gastrostomy and 13, jejunostomy…

  15. Vertical gastroplasty: evolution of vertical banded gastroplasty.

    Science.gov (United States)

    Mason, E E; Doherty, C; Cullen, J J; Scott, D; Rodriguez, E M; Maher, J W

    1998-09-01

    The objective of this paper is to summarize the goals, technical requirements, advantages, and potential risks of gastroplasty for treatment of severe obesity. Gastroplasty is preferred to more complex operations, as it preserves normal digestion and absorption and avoids complications that are peculiar to exclusion operations. The medical literature and a 30-year experience at the University of Iowa Hospitals and Clinics (UIHC) provides an overview of vertical banded gastroplasty (VBG) evolution. Preliminary 10-year results with the VBG technique currently used at UIHC are included. At UIHC the VBG is preferred to other gastroplasties because it provides weight control that extends for at least 10 years and the required objective, intraoperative quality control required for a low rate of reoperation. It is recommended that modifications of the operative technique not be attempted until a surgeon has had experience with the standardized operation--and then only under a carefully designed protocol. Realistic goals for surgery and criteria of success influence the choice of operation and the optimum, lifelong risk/benefit ratio. In conclusion, VBG is a safe, long-term effective operation for severe obesity with advantages over complex operations and more restrictive simple operations.

  16. Vortex tube optimization theory

    Energy Technology Data Exchange (ETDEWEB)

    Lewins, Jeffery [Cambridge Univ., Magdalene Coll., Cambridge (United Kingdom); Bejan, Adrian [Duke Univ., Dept. of Mechanical Engineering and Materials Science, Durham, NC (United States)

    1999-11-01

    The Ranque-Hilsch vortex tube splits a single high pressure stream of gas into cold and warm streams. Simple models for the vortex tube combined with regenerative precooling are given from which an optimisation can be undertaken. Two such optimisations are needed: the first shows that at any given cut or fraction of the cold stream, the best refrigerative load, allowing for the temperature lift, is nearly half the maximum loading that would result in no lift. The second optimisation shows that the optimum cut is an equal division of the vortex streams between hot and cold. Bounds are obtainable within this theory for the performance of the system for a given gas and pressure ratio. (Author)

  17. YouTube Physics

    Science.gov (United States)

    Riendeau, Diane

    2012-09-01

    To date, this column has presented videos to show in class, Don Mathieson from Tulsa Community College suggested that YouTube could be used in another fashion. In Don's experience, his students are not always prepared for the mathematic rigor of his course. Even at the high school level, math can be a barrier for physics students. Walid Shihabi, a colleague of Don's, decided to compile a list of YouTube videos that his students could watch to relearn basic mathematics. I thought this sounded like a fantastic idea and a great service to the students. Walid graciously agreed to share his list and I have reproduced a large portion of it below.

  18. Neural tube defects

    Directory of Open Access Journals (Sweden)

    M.E. Marshall

    1981-09-01

    Full Text Available Neural tube defects refer to any defect in the morphogenesis of the neural tube, the most common types being spina bifida and anencephaly. Spina bifida has been recognised in skeletons found in north-eastern Morocco and estimated to have an age of almost 12 000 years. It was also known to the ancient Greek and Arabian physicians who thought that the bony defect was due to the tumour. The term spina bifida was first used by Professor Nicolai Tulp of Amsterdam in 1652. Many other terms have been used to describe this defect, but spina bifida remains the most useful general term, as it describes the separation of the vertebral elements in the midline.

  19. Falling film evaporation on a single tube and on a tube bundle

    OpenAIRE

    Roques, Jean-François; Thome, John Richard

    2005-01-01

    This study is a contribution for the improvement of horizontal falling film heat exchangers. This type of evaporator has the potential to be widely used in the petrochemical industry, for the sea water desalination, or in the large refrigeration systems. An experimental test facility has been constructed in order to study the evaporation of the liquid refrigerant R-134a flowing on a vertical array of horizontal copper tubes with a length of 0.55 meter and a diameter of 19.1mm. Special care ha...

  20. Falling film evaporation on a single tube and on a tube bundle

    OpenAIRE

    Roques, Jean-François

    2004-01-01

    This study is a contribution for the improvement of horizontal falling film heat exchangers. This type of evaporator has the potential to be widely used in the petrochemical industry, for the sea water desalination, or in the large refrigeration systems. An experimental test facility has been constructed in order to study the evaporation of the liquid refrigerant R-134a flowing on a vertical array of horizontal copper tubes with a length of 0.55 meter and a diameter of 19.1mm. Special care ha...

  1. Diffusion in Tube Dialyzer

    Directory of Open Access Journals (Sweden)

    Yohannes Nigatie

    2017-09-01

    Full Text Available Nowadays, kidney failure is a problem of many peoples in the world. We know that the main function of kidney is maintaining the chemical quality of blood particularly removing urea through urine. But when they malfunction, the pathologic state known as uremia results in a condition in which the urea is retained in the body. Failure of the kidney results in building up of harmful wastes and excess fluids in the body. Kidney diseases (failures can be due to infections, high blood pressure (hypertension, diabetes, and/or extensive use of medication. The best form of treatment is the implantation of a healthy kidney from a donor. However, this is often not possible due to the limited availability of human organs. Chronic kidney failure requires the treatment using a tube dialyzer called dialysis. Blood is taken out of the body and passes through a special membrane that removes waste and extra fluids. The clean blood is then returned to the body. The process is controlled by a dialysis machine (tube dialyzer which is equipped with a blood pump and monitoring systems to ensure safety. So this article investigates the real application of mathematics (diffusion in medical science, and it also contains the mathematical formulation and interpretation of tube dialyzer in relation to diffusion.

  2. Liquid film dynamics in horizontal and tilted tubes: Dry spots and sliding drops

    Science.gov (United States)

    King, A. A.; Cummings, L. J.; Naire, S.; Jensen, O. E.

    2007-04-01

    Using a model derived from lubrication theory, we consider the evolution of a thin viscous film coating the interior or exterior of a cylindrical tube. The flow is driven by surface tension and gravity and the liquid is assumed to wet the cylinder perfectly. When the tube is horizontal, we use large-time simulations to describe the bifurcation structure of the capillary equilibria appearing at low Bond number. We identify a new film configuration in which an isolated dry patch appears at the top of the tube and demonstrate hysteresis in the transition between rivulets and annular collars as the tube length is varied. For a tube tilted to the vertical, we show how a long initially uniform rivulet can break up first into isolated drops and then annular collars, which subsequently merge. We also show that the speed at which a localized drop moves down the base of a tilted tube is nonmonotonic in tilt angle.

  3. Reliability of steam generator tubing

    Energy Technology Data Exchange (ETDEWEB)

    Kadokami, E. [Mitsubishi Heavy Industries Ltd., Hyogo-ku (Japan)

    1997-02-01

    The author presents results on studies made of the reliability of steam generator (SG) tubing. The basis for this work is that in Japan the issue of defects in SG tubing is addressed by the approach that any detected defect should be repaired, either by plugging the tube or sleeving it. However, this leaves open the issue that there is a detection limit in practice, and what is the effect of nondetectable cracks on the performance of tubing. These studies were commissioned to look at the safety issues involved in degraded SG tubing. The program has looked at a number of different issues. First was an assessment of the penetration and opening behavior of tube flaws due to internal pressure in the tubing. They have studied: penetration behavior of the tube flaws; primary water leakage from through-wall flaws; opening behavior of through-wall flaws. In addition they have looked at the question of the reliability of tubing with flaws during normal plant operation. Also there have been studies done on the consequences of tube rupture accidents on the integrity of neighboring tubes.

  4. Gallium-assisted growth of flute-like MgO nanotubes, Ga2O3-filled MgO nanotubes, and MgO/Ga2O3 co-axial nanotubes.

    Science.gov (United States)

    Jie, Jiansheng; Wu, Chunyan; Yu, Yongqiang; Wang, Li; Hu, Zhizhong

    2009-02-18

    Flute-like MgO nanotubes were successfully synthesized via a simple thermal evaporation method by using Mg(3)N(2) and Ga(2)O(3) as the source materials. The nanotubes are single-crystal cubic MgO, and have [100] orientation. In contrast to conventional nanotubes with intact walls, the flute-like MgO nanotubes possess a unique porous structure. On the nanotubes there are series of holes aligned along the nanotube length with approximate equidistance. Ga(2)O(3)-filled MgO nanotubes and MgO/Ga(2)O(3) co-axial nanotubes were also found in the product. Further investigation confirms that the inner beta-Ga(2)O(3) has an epitaxial growth relation with the outer MgO nanotube due to their perfect lattice matching. A gallium-assisted growth mechanism was proposed to interpret the growth of the flute-like MgO nanotubes. The thermal expansion and evaporation of the filled liquid gallium in MgO nanotubes are likely responsible for the formation of the hole structures on the side walls.

  5. Steam generator tube integrity program

    Energy Technology Data Exchange (ETDEWEB)

    Dierks, D.R.; Shack, W.J. [Argonne National Laboratory, IL (United States); Muscara, J.

    1996-03-01

    A new research program on steam generator tubing degradation is being sponsored by the U.S. Nuclear Regulatory Commission (NRC) at Argonne National Laboratory. This program is intended to support a performance-based steam generator tube integrity rule. Critical areas addressed by the program include evaluation of the processes used for the in-service inspection of steam generator tubes and recommendations for improving the reliability and accuracy of inspections; validation and improvement of correlations for evaluating integrity and leakage of degraded steam generator tubes, and validation and improvement of correlations and models for predicting degradation in steam generator tubes as aging occurs. The studies will focus on mill-annealed Alloy 600 tubing, however, tests will also be performed on replacement materials such as thermally-treated Alloy 600 or 690. An overview of the technical work planned for the program is given.

  6. Measurement of Heat Transfer Coefficients in an Agitated Vessel with Tube Baffles

    OpenAIRE

    M. Dostál; Petera, K.; Rieger, F.

    2010-01-01

    Cooling or heating an agitated liquid is a very common operation in many industrial processes. A classic approach is to transfer the necessary heat through the vessel jacket. Another option, frequently used in the chemical and biochemical industries is to use the heat transfer area of vertical tube baffles. In large equipment, e.g. fermentor, the jacket surface is often not sufficient for large heat transfer requirements and tube baffles can help in such cases. It is then important to know th...

  7. GPS, su datum vertical.

    Directory of Open Access Journals (Sweden)

    Esteban Dörries

    2016-03-01

    Full Text Available La introducción de la metodología GPS en aplicaciones topográficas y geodésicas pone en notoria evidencia la clásica separación de sistemas de referencia en horizontal y vertical. Con GPS el posicionamiento es tridimensional, pero el concepto de altura difiere del clásico. Si se desea utilizar la información altimétrica debe contemplarse la ondulación del geoide.

  8. Projectile Balloting Attributable to Gun Tube Curvature

    Directory of Open Access Journals (Sweden)

    Michael M. Chen

    2010-01-01

    Full Text Available Transverse motion of a projectile during launch is detrimental to firing accuracy, structural integrity, and/or on-board electronics performance of the projectile. One manifest contributing factor to the undesired motion is imperfect bore centerline straightness. This paper starts with the presentation of a deterministic barrel model that possesses both vertical and lateral deviations from centerline in accordance with measurement data, followed by a novel approach to simulating comprehensive barrel centerline variations for the investigation of projectile balloting^1 motions. A modern projectile was adopted for this study. In-bore projectile responses at various locations of the projectile while traveling through the simulated gun tubes were obtained. The balloting was evaluated in both time and frequency domains. Some statistical quantities and the significance were outlined.

  9. Diffusion in a Curved Tube

    OpenAIRE

    Ogawa, Naohisa

    2011-01-01

    The diffusion of particles in confining walls forming a tube is discussed. Such a transport phenomenon is observed in biological cells and porous media. We consider the case in which the tube is winding with curvature and torsion, and the thickness of the tube is sufficiently small compared with its curvature radius. We discuss how geomerical quantities appear in a quasi-one-dimensional diffusion equation.

  10. Alternate tube plugging criteria for steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Cueto-Felgueroso, C.; Aparicio, C.B. [Tecnatom, S.A., Madrid (Spain)

    1997-02-01

    The tubing of the Steam Generators constitutes more than half of the reactor coolant pressure boundary. Specific requirements governing the maintenance of steam generator tubes integrity are set in Plant Technical Specifications and in Section XI of the ASME Boiler and Pressure Vessel Code. The operating experience of Steam Generator tubes of PWR plants has shown the existence of some types of degradatory processes. Every one of these has an specific cause and affects one or more zones of the tubes. In the case of Spanish Power Plants, and depending on the particular Plant considered, they should be mentioned the Primary Water Stress Corrosion Cracking (PWSCC) at the roll transition zone (RTZ), the Outside Diameter Stress Corrosion Cracking (ODSCC) at the Tube Support Plate (TSP) intersections and the fretting with the Anti-Vibration Bars (AVBs) or with the Support Plates in the preheater zone. The In-Service Inspections by Eddy Currents constitutes the standard method for assuring the SG tubes integrity and they permit the monitoring of the defects during the service life of the plant. When the degradation reaches a determined limit, called the plugging limit, the SG tube must be either repaired or retired from service by plugging. Customarily, the plugging limit is related to the depth of the defect. Such depth is typically 40% of the wall thickness of the tube and is applicable to any type of defect in the tube. In its origin, that limit was established for tubes thinned by wastage, which was the predominant degradation in the seventies. The application of this criterion for axial crack-like defects, as, for instance, those due to PWSCC in the roll transition zone, has lead to an excessive and unnecessary number of tubes being plugged. This has lead to the development of defect specific plugging criteria. Examples of the application of such criteria are discussed in the article.

  11. YouTube and 'psychiatry'.

    Science.gov (United States)

    Gordon, Robert; Miller, John; Collins, Noel

    2015-12-01

    YouTube is a video-sharing website that is increasingly used to share and disseminate health-related information, particularly among younger people. There are reports that social media sites, such as YouTube, are being used to communicate an anti-psychiatry message but this has never been confirmed in any published analysis of YouTube clip content. This descriptive study revealed that the representation of 'psychiatry' during summer 2012 was predominantly negative. A subsequent smaller re-analysis suggests that the negative portrayal of 'psychiatry' on YouTube is a stable phenomenon. The significance of this and how it could be addressed are discussed.

  12. Bacterial Biofilms in Jones Tubes.

    Science.gov (United States)

    Ahn, Eric S; Hauck, Matthew J; Kirk Harris, Jonathan; Robertson, Charles E; Dailey, Roger A

    To investigate the presence and microbiology of bacterial biofilms on Jones tubes (JTs) by direct visualization with scanning electron microscopy and polymerase chain reaction (PCR) of representative JTs, and to correlate these findings with inflammation and/or infection related to the JT. In this study, prospective case series were performed. JTs were recovered from consecutive patients presenting to clinic for routine cleaning or recurrent irritation/infection. Four tubes were processed for scanning electron microscopy alone to visualize evidence of biofilms. Two tubes underwent PCR alone for bacterial quantification. One tube was divided in half and sent for scanning electron microscopy and PCR. Symptoms related to the JTs were recorded at the time of recovery. Seven tubes were obtained. Five underwent SEM, and 3 out of 5 showed evidence of biofilms (60%). Two of the 3 biofilms demonstrated cocci and the third revealed rods. Three tubes underwent PCR. The predominant bacteria identified were Pseudomonadales (39%), Pseudomonas (16%), and Staphylococcus (14%). Three of the 7 patients (43%) reported irritation and discharge at presentation. Two symptomatic patients, whose tubes were imaged only, revealed biofilms. The third symptomatic patient's tube underwent PCR only, showing predominantly Staphylococcus (56%) and Haemophilus (36%) species. Two of the 4 asymptomatic patients also showed biofilms. All symptomatic patients improved rapidly after tube exchange and steroid antibiotic drops. Bacterial biofilms were variably present on JTs, and did not always correlate with patients' symptoms. Nevertheless, routine JT cleaning is recommended to treat and possibly prevent inflammation caused by biofilms.

  13. Learning from YouTube [Video Book

    Science.gov (United States)

    Juhasz, Alexandra

    2011-01-01

    YouTube is a mess. YouTube is for amateurs. YouTube dissolves the real. YouTube is host to inconceivable combos. YouTube is best for corporate-made community. YouTube is badly baked. These are a few of the things Media Studies professor Alexandra Juhasz (and her class) learned about YouTube when she set out to investigate what actually happens…

  14. Infrared imaging of LED lighting tubes and fluorescent tubes

    Science.gov (United States)

    Siikanen, Sami; Kivi, Sini; Kauppinen, Timo; Juuti, Mikko

    2011-05-01

    The low energy efficiency of conventional light sources is mainly caused by generation of waste heat. We used infrared (IR) imaging in order to monitor the heating of both LED tube luminaires and ordinary T8 fluorescent tubes. The IR images showed clearly how the surface temperatures of the fluorescent tube ends quickly rose up to about +50...+70°C, whereas the highest surface temperatures seen on the LED tubes were only about +30...+40°C. The IR images demonstrated how the heat produced by the individual LED chips can be efficiently guided to the supporting structure in order to keep the LED emitters cool and hence maintain efficient operation. The consumed electrical power and produced illuminance were also recorded during 24 hour measurements. In order to assess the total luminous efficacy of the luminaires, separate luminous flux measurements were made in a large integrating sphere. The currently available LED tubes showed efficacies of up to 88 lm/W, whereas a standard "cool white" T8 fluorescent tube produced ca. 75 lm/W. Both lamp types gave ca. 110 - 130 lx right below the ceiling-mounted luminaire, but the LED tubes consume only 40 - 55% of the electric power compared to fluorescent tubes.

  15. Drop tube technical tasks

    Science.gov (United States)

    Workman, G. L.

    1986-01-01

    Criteria, using fundamental thermochemical dynamics, were developed to assist a scientist using the Drop Tube Facility in designing a good experiment. The types of parameters involved in designing the experiments include the type of furnace, the type of atmosphere, and in general which materials are better behaved than others as determined by past experience in the facility. One of the major advantages of the facility lies in its ability to provide large undercoolings in the cooling curve during the drops. A beginning was to consider the effect of oxygen and other gases upon the amount of undercooling observed. The starting point of the thermochemistry was given by Ellingham and later transformed into what is known as the Richardson Chart. The effect of surface oxidations upon the nucleation phenomena can be observed in each specimen.

  16. Nasoenteric tube complications.

    Science.gov (United States)

    Prabhakaran, S; Doraiswamy, V A; Nagaraja, V; Cipolla, J; Ofurum, U; Evans, D C; Lindsey, D E; Seamon, M J; Kavuturu, S; Gerlach, A T; Jaik, N P; Eiferman, D S; Papadimos, T J; Adolph, M D; Cook, C H; Stawicki, S P A

    2012-01-01

    The use of nasoenteric tubes (NETs) is ubiquitous, and clinicians often take their placement, function, and maintenance for granted. NETs are used for gastrointestinal decompression, enteral feeding, medication administration, naso-biliary drainage, and specialized indications such as upper gastrointestinal bleeding. Morbidity associated with NETs is common, but frequently subtle, mandating high index of suspicion, clinical vigilance, and patient safety protocols. Common complications include sinusitis, sore throat and epistaxis. More serious complications include luminal perforation, pulmonary injury, aspiration, and intracranial placement. Frequent monitoring and continual re-review of the indications for continued use of any NET is prudent, including consideration of changing goals of care. This manuscript reviews NET-related complications and associated topics.

  17. Piezoelectric Rotary Tube Motor

    Science.gov (United States)

    Fisher, Charles D.; Badescu, Mircea; Braun, David F.; Culhane, Robert

    2011-01-01

    A custom rotary SQUIGGLE(Registered TradeMark) motor has been developed that sets new benchmarks for small motor size, high position resolution, and high torque without gear reduction. Its capabilities cannot be achieved with conventional electromagnetic motors. It consists of piezoelectric plates mounted on a square flexible tube. The plates are actuated via voltage waveforms 90 out of phase at the resonant frequency of the device to create rotary motion. The motors were incorporated into a two-axis postioner that was designed for fiber-fed spectroscopy for ground-based and space-based projects. The positioner enables large-scale celestial object surveys to take place in a practical amount of time.

  18. Boiling Heat Transfer of a Refrigerant Flowing Vertically Downward in a Mini-channel

    Science.gov (United States)

    Miyata, Kazushi; Mori, Hideo; Ohishi, Katsumi; Hamamoto, Yoshinori

    Experiments were performed on boiling heat transfer of a refrigerant R-410A flowing vertically downward in a copper rectangular tube and a triangular tube of 1.04 mm and 0.88 mm inside hydraulic diameter, respectively,for the development of a high-performance heat exchanger using small tubes or multi-port extruded tubes for air conditioning systems. Local heat transfer coefficients were measured in a range of mass fluxes from 30 to 200kg/(m2s), heat fluxes from 1 to 20 kW/m2 and quality from 0.05 to 1 at the evaporation temperature of 10 °C.Characteristics of the heat transfer coefficient and dryout quality were clarified by comparing the measurements with the data for the circular tube of 1.0 mm inside diameter previously obtained.

  19. Vertical compact torus injection into the STOR-M tokamak

    Science.gov (United States)

    Liu, Dazhi

    experiments have been performed in STOR-M by using the USCTI device (University of Saskatchewan Compact Torus Injector). To perform vertical injection, the original USCTI has been modified by attaching a segment of 90° curved tube to deflect CT injection from horizontal to vertical direction. Therefore, a CT formed and accelerated by USCTI in horizontal direction will change its trajectory to vertical and be injected into STOR-M through a vertical port. The main findings of this thesis are: (1) The horizontally injected CT could be deflected to the vertical direction with a velocity ˜ 130 kms-1 and penetrated into the STOR-M plasma by the curved drift tube. A significant increase in the CT velocity after passing the curved tube, from 130 kms-1 to 270 kms-1, has been achieved by further attaching a copper inner electrode. (2) Vertical compact torus injection for fuelling a tokamak has been successfully demonstrated for the first time. Disruption-free discharges of STOR-M have been obtained with vertical CT injection. Prompt increases both in line-averaged density and in the soft X-ray emission level have been observed. The typical density increase is about 20% within 600 mus. Some signatures of confinement improvement of the STOR-M plasma induced by vertical CT injection have also been observed.

  20. Vertical Protocol Composition

    DEFF Research Database (Denmark)

    Groß, Thomas; Mödersheim, Sebastian Alexander

    2011-01-01

    composition, and it is truly commonplace in today’s communication with the diversity of VPNs and secure browser sessions. In fact, it is normal that we have several layers of secure channels: For instance, on top of a VPN-connection, a browser may establish another secure channel (possibly with a different...... end point). Even using the same protocol several times in such a stack of channels is not unusual: An application may very well establish another TLS channel over an established one. We call this selfcomposition. In fact, there is nothing that tells us that all these compositions are sound, i.......e., that the combination cannot introduce attacks that the individual protocols in isolation do not have. In this work, we prove a composability result in the symbolic model that allows for arbitrary vertical composition (including self-composition). It holds for protocols from any suite of channel and application...

  1. Vertical cavity laser

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention provides a vertical cavity laser comprising a grating layer comprising an in-plane grating, the grating layer having a first side and having a second side opposite the first side and comprising a contiguous core grating region having a grating structure, wherein an index......, an index of refraction of the second low-index layer or air being less than 2; and a thickness of the cap layer and a thickness of the grating layer, and a pitch and a duty cycle of the grating structure are selected to obtain a resonance having a free-space resonance wavelength in the interval 300 nm to 3...... microns, the cap layer comprises an active region configured to generate or absorb photons at the free-space resonance wavelength by stimulated emission or absorption when a sufficient forward or reverse bias voltage is applied across the active region, a thickness of the first low-index layer is less...

  2. Flaming on YouTube

    NARCIS (Netherlands)

    Moor, Peter J.; Heuvelman, A.; Verleur, R.

    2010-01-01

    In this explorative study, flaming on YouTube was studied using surveys of YouTube users. Flaming is defined as displaying hostility by insulting, swearing or using otherwise offensive language. Three general conclusions were drawn. First, although many users said that they themselves do not flame,

  3. Enteral tube feeding in adults.

    Science.gov (United States)

    Scott, R; Bowling, T E

    2015-03-01

    Enteral tube feeding is usually a relatively straightforward method of nutritional support, and should be facilitated by a multiprofessional team. For short-term use (tube is indicated but if longer term feeding is required then a gastrostomy is appropriate, usually inserted endoscopically (a percutaneous endoscopic gastrostomy tube). The most common serious complication of a nasogastric tube is not identifying a misplaced tube within the lungs: there are clear recommendations from the National Patient Safety Agency as to how to check tube placement. Nasojejunal tubes are required in patients with gastroparesis. Tube blockage is common and is prevented by careful and regular flushing. Diarrhoea is the most complication of feeding and is often related to other medication. Clinicians need an algorithm for systematically dealing with such a problem. Refeeding syndrome may occur in malnourished patients and is characterised by low levels of potassium, phosphate, and/or magnesium, as well as disorders of water and salt balance. Identifying the at-risk patient with careful monitoring is crucial.

  4. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: Amblyopia NEI Home Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  5. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs ... search for current job openings visit HHS USAJobs Home > NEI YouTube Videos > NEI YouTube Videos: Amblyopia NEI ...

  6. Direct Observation of Ultralow Vertical Emittance using a Vertical Undulator

    Energy Technology Data Exchange (ETDEWEB)

    Wootton, Kent

    2015-09-17

    In recent work, the first quantitative measurements of electron beam vertical emittance using a vertical undulator were presented, with particular emphasis given to ultralow vertical emittances [K. P. Wootton, et al., Phys. Rev. ST Accel. Beams, 17, 112802 (2014)]. Using this apparatus, a geometric vertical emittance of 0.9 ± 0.3 pm rad has been observed. A critical analysis is given of measurement approaches that were attempted, with particular emphasis on systematic and statistical uncertainties. The method used is explained, compared to other techniques and the applicability of these results to other scenarios discussed.

  7. 27 CFR 40.352 - Cigarette tubes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Cigarette tubes. 40.352... OF THE TREASURY (CONTINUED) TOBACCO MANUFACTURE OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO Manufacture of Cigarette Papers and Tubes Taxes § 40.352 Cigarette tubes. Cigarette tubes...

  8. Drug administration via nasogastric tube.

    Science.gov (United States)

    Clarke, Sonya

    2008-09-01

    In 2005, the National Patient Safety Agency (NPSA) highlighted concerns about the management of nasogastric tubes following reports of unnecessary deaths because of misplaced feeding tubes in infants, children and adults. During 2006, I investigated the management of nasogastric tubes (NGTs) in children (Clarke and Richardson 2007a, 2007b). This systematic review divided primary papers into three principal themes: enteral feeding via the NGT; confirmation of NGT position and associated incidence of tube placement error; and hydration via the NGT for acute gastroenteritis in children. Findings of the review are summarised here in relation to using the nasogastric tube to administer medication to children with the aim of informing practice and improving safety.

  9. Vertical allometry: fact or fiction?

    Science.gov (United States)

    Mahmood, Iftekhar; Boxenbaum, Harold

    2014-04-01

    In pharmacokinetics, vertical allometry is referred to the clearance of a drug when the predicted human clearance is substantially higher than the observed human clearance. Vertical allometry was initially reported for diazepam based on a 33-fold higher human predicted clearance than the observed human clearance. In recent years, it has been found that many other drugs besides diazepam, can be classified as drugs which exhibit vertical allometry. Over the years, many questions regarding vertical allometry have been raised. For example, (1) How to define and identify the vertical allometry? (2) How much difference should be between predicted and observed human clearance values before a drug could be declared 'a drug which follows vertical allometry'? (3) If somehow one can identify vertical allometry from animal data, how this information can be used for reasonably accurate prediction of clearance in humans? This report attempts to answer the aforementioned questions. The concept of vertical allometry at this time remains complex and obscure but with more extensive works one can have better understanding of 'vertical allometry'. Published by Elsevier Inc.

  10. Eddy current signal comparison for tube identification

    Science.gov (United States)

    Glass, S. W.; Vojvodic, R.

    2015-03-01

    Inspection of nuclear power plant steam generator tubes is required to justify continued safe plant operation. The steam generators consist of thousands of tubes with nominal diameters of 15 to 22mm, approximately 1mm wall thickness, and 20 to 30m in length. The tubes are inspected by passing an eddy current probe through the tubes from tube end to tube end. It is critical to know exactly which tube identification (row and column) is associated with each tube's data. This is controlled by a precision manipulator that provides the tube ID to the eddy current system. Historically there have been some instances where the manipulator incorrectly reported the tube ID. This can have serious consequences including lack of inspection of a tube, or if a pluggable indication is detected, the tube is likely to be mis-plugged thereby risking a primary to secondary leak.

  11. Water-storage-tube systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemker, P.

    1981-12-24

    Passive solar collection/storage/distribution systems were surveyed, designed, fabricated, and mechanically and thermally tested. The types studied were clear and opaque fiberglass tubes, metal tubes with plastic liners, and thermosyphoning tubes. (MHR)

  12. Flux tubes at finite temperature

    Energy Technology Data Exchange (ETDEWEB)

    Cea, Paolo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Dipartimento di Fisica dell’Università di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cosmai, Leonardo [INFN, Sezione di Bari,Via G. Amendola 173, I-70126 Bari (Italy); Cuteri, Francesca; Papa, Alessandro [Dipartimento di Fisica, Università della Calabria & INFN-Cosenza,Ponte Bucci, cubo 31C, I-87036 Rende (Cosenza) (Italy)

    2016-06-07

    The chromoelectric field generated by a static quark-antiquark pair, with its peculiar tube-like shape, can be nicely described, at zero temperature, within the dual superconductor scenario for the QCD confining vacuum. In this work we investigate, by lattice Monte Carlo simulations of the SU(3) pure gauge theory, the fate of chromoelectric flux tubes across the deconfinement transition. We find that, if the distance between the static sources is kept fixed at about 0.76 fm ≃1.6/√σ and the temperature is increased towards and above the deconfinement temperature T{sub c}, the amplitude of the field inside the flux tube gets smaller, while the shape of the flux tube does not vary appreciably across deconfinement. This scenario with flux-tube “evaporation” above T{sub c} has no correspondence in ordinary (type-II) superconductivity, where instead the transition to the phase with normal conductivity is characterized by a divergent fattening of flux tubes as the transition temperature is approached from below. We present also some evidence about the existence of flux-tube structures in the magnetic sector of the theory in the deconfined phase.

  13. Method of making straight fuel cell tubes

    Science.gov (United States)

    Borglum, Brian P.

    2001-01-01

    A method and an apparatus for making straight fuel cell tubes are disclosed. Extruded tubes comprising powders of fuel cell material and a solvent are dried by rotating the extruded tubes. The rotation process provides uniform circumferential drying which results in uniform linear shrinkage of the tubes. The resultant dried tubes are very straight, thereby eliminating subsequent straightening steps required with conventional processes. The method is particularly useful for forming inner air electrode tubes of solid oxide fuel cells.

  14. Computer cooling using a two phase minichannel thermosyphon loop heated from horizontal and vertical sides and cooled from vertical side

    Science.gov (United States)

    Bieliński, Henryk; Mikielewicz, Jarosław

    2010-10-01

    In the present paper it is proposed to consider the computer cooling capacity using the thermosyphon loop. A closed thermosyphon loop consists of combined two heaters and a cooler connected to each other by tubes. The first heater may be a CPU processor located on the motherboard of the personal computer. The second heater may be a chip of a graphic card placed perpendicular to the motherboard of personal computer. The cooler can be placed above the heaters on the computer chassis. The thermosyphon cooling system on the use of computer can be modeled using the rectangular thermosyphon loop with minichannels heated at the bottom horizontal side and the bottom vertical side and cooled at the upper vertical side. The riser and a downcomer connect these parts. A one-dimensional model of two-phase flow and heat transfer in a closed thermosyphon loop is based on mass, momentum, and energy balances in the evaporators, rising tube, condenser and the falling tube. The separate two-phase flow model is used in calculations. A numerical investigation for the analysis of the mass flux rate and heat transfer coefficient in the steady state has been accomplished.

  15. PEG tubes: dealing with complications.

    Science.gov (United States)

    Malhi, Hardip; Thompson, Rosie

    A percutaneous endoscopic gastronomy tube can be used to deliver nutrition, hydration and medicines directly into the patient's stomach. Patients will require a tube if they are unable to swallow safely, putting them at risk of aspiration of food, drink and medicines into their lungs. It is vital that nurses are aware of the complications that may arise when caring for a patient with a PEG tube. It is equally important that nurses know how to deal with these complications or from where tc seek advice. This article provides a quick troubleshooting guide to help nurses deal with complications that can arise with PEG feeding.

  16. Glass Tube Design for CRT(Cathode Ray Tube)

    OpenAIRE

    Junko, ITOH; Keizo, KISHIDA; Koji, NAKAMURA; Masayuki, Miyazaki; Shigeo, OHSUGI; Sumio, YOSHIOKA; Department of Precision Science & Technology, Osaka University; Mitsubishi Elec.Corp.

    2000-01-01

    Stress and deformation of cathode ray tubes(CRTs)under atmospheric pressure and implosion protection band tightening were analyzed using a finite element method(FEM). The stress and deformation of the tubes were measured experimentally by using strain gages and three-dimensional position measuring techniques. The experimental results showed close agreements with those of the simulation. The location of the highest tensile stress and the effects of tightening of the implosion protection bands ...

  17. Cannon de Hermeto Pascoal: aspectos musicais e religiosos em uma obra-prima para flauta Cannon by Hermeto Pascoal: musical and religious aspects in a flute masterpiece

    Directory of Open Access Journals (Sweden)

    Fausto Borém

    2010-12-01

    Full Text Available Estudo de caso sobre Cannon de Hermeto Pascoal, obra para flauta, humming na flauta e sons pré-gravados, planejada como uma sessão espírita musical e gravada pelo compositor no disco Slaves Mass (PASCOAL, 1977. A partir do desenho artístico de uma pauta espiralada na capa interna do mesmo LP (PASCOAL e PEREIRA, 1977 e de uma transcrição baseada na faixa gravada, a partitura da obra foi detalhadamente reconstituída e editada (PASCOAL e BORÉM, 2010; incluída neste volume de Per Musi às p.80-82. A combinação das análises formal, escalar e proporcional da partitura e seu cruzamento com a análise espectral da gravação revelam grande unidade e uma íntima relação entre os conteúdos musicais e extra-musicais da obra, na qual elementos opostos dialogam: a improvisação e as camadas de superposição de sons pré-gravados, a sonoridade acústica e os sons manipulados, a performance individual e a coletiva, a estabilidade e a instabilidade modal, as linguagens popular (embolada, jazz modal, free jazz e erudita (música concreta, atonalismo, cadenza, recitativo, os mundos terreno e espiritual. Apresenta também, em primeira mão, a abordagem analítica do "continuum separação-fusão paradoxal" da obra, a partir de ferramenta etnomusicológica criada e realizada por COSTA-LIMA NETO (2009. Inclui uma contextualização do papel da religião na música do "mago" multi-instrumentista, arranjador e compositor da música popular brasileira.Case study on Cannon by Brazilian composer, arranger and multi-instrumentalist Hermeto Pascoal, a work for flute, flute humming and pre-recorded sounds, designed as a musical spiritism session and included in the LP Slaves Mass (PASCOAL, 1977. Departing from an artistic drawing of a music staff spiral included in the internal covers of the same LP (PASCOAL e PEREIRA, 1977 and a transcription based on the listening of the track in the same disc, the score of the work was reconstituted and edited in detail

  18. Protected Vertices in Motzkin trees

    OpenAIRE

    Van Duzer, Anthony

    2017-01-01

    In this paper we find recurrence relations for the asymptotic probability a vertex is $k$ protected in all Motzkin trees. We use a similar technique to calculate the probabilities for balanced vertices of rank $k$. From this we calculate upper and lower bounds for the probability a vertex is balanced and upper and lower bounds for the expected rank of balanced vertices.

  19. One-dimensional model for heat transfer to a supercritical water flow in a tube

    NARCIS (Netherlands)

    Sallevelt, J.L.H.P.; Withag, J.A.M.; Bramer, Eduard A.; Brilman, Derk Willem Frederik; Brem, Gerrit

    2012-01-01

    Heat transfer in water at supercritical pressures has been investigated numerically using a one-dimensional modeling approach. A 1D plug flow model has been developed in order to make fast predictions of the bulk-fluid temperature in a tubular flow. The chosen geometry is a vertical tube with an

  20. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded ...

  1. Epidemiology of neural tube defects

    National Research Council Canada - National Science Library

    Seidahmed, Mohammed Z; Abdelbasit, Omar B; Shaheed, Meeralebbae M; Alhussein, Khalid A; Miqdad, Abeer M; Khalil, Mohamed I; Al-Enazy, Naif M; Salih, Mustafa A

    2014-01-01

    To find the prevalence of neural tube defects (NTDs), and compare the findings with local and international data, and highlight the important role of folic acid supplementation and flour fortification with folic acid in preventing NTDs...

  2. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home > NEI YouTube Videos > ...

  3. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division ... Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video ...

  4. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home > NEI YouTube Videos > ...

  5. Examination of gavage tube placement in children.

    Science.gov (United States)

    Ellett, M L; Beckstrand, J

    1999-01-01

    A primary issue in ensuring safe and effective enteral feeding by tube is achieving and maintaining correct tube position. This study was conducted to determine the prevalence of tube placement errors, risk factors associated with these errors, and accuracy of commonly used bedside placement-screening methods. In this descriptive study, 39 hospitalized children having one or more types of enteral tubes were studied prospectively. Tube placement was assessed across time, using three common placement-screening methods compared to radiographs. Tube placement error occurred in 43.5% of tubes at least once during the observation period. Children who were comatose or semicomatose, were inactive, had swallowing problems, or had Argyle tubes were more likely to have tube placement errors. Findings suggest that radiographs to document tube placement may be needed, at least on initial enteral tube insertion.

  6. Bearing Capacities of Different-Diameter Concrete-Filled Steel Tubes under Axial Compression

    Directory of Open Access Journals (Sweden)

    Wenjing Wang

    2016-01-01

    Full Text Available The bearing capacities of concrete-filled steel tubes are normally derived through experiments with small-scale specimens, but it is uncertain whether such derivations are appropriate for the much larger components used in practical engineering. This study therefore investigates the effect of different diameters (219, 426, 630, and 820 mm on the axial compression of short concrete columns in steel (Q235 tubes. It is found that the peak nominal stress decreases with increasing specimen size and that the axial bearing capacity is determined by three separate components: the cylinder compressive strength of the concrete, the improvement in strength due to the confining effect of the steel tube, and the longitudinal strength of the steel tube. At peak load, increases in the specimen diameter reduce the hoop stresses in the steel tube, thereby reducing the strengthening effect of confinement. Vertical stress in the steel tube is increased with diameter; therefore, the axial bearing capacity of the steel tube is directly related to the specimen size. Size effect coefficients for these three aspects of bearing capacity are defined and used to develop a size-dependent model for predicting the axial bearing capacity of large, concrete-filled steel tubes. The model is then validated against experimental data.

  7. Dermatology on YouTube.

    Science.gov (United States)

    Boyers, Lindsay N; Quest, Tyler; Karimkhani, Chante; Connett, Jessica; Dellavalle, Robert P

    2014-06-15

    YouTube, reaches upwards of six billion users on a monthly basis and is a unique source of information distribution and communication. Although the influence of YouTube on personal health decision-making is well established, this study assessed the type of content and viewership on a broad scope of dermatology related content on YouTube. Select terms (i.e. dermatology, sun protection, skin cancer, skin cancer awareness, and skin conditions) were searched on YouTube. Overall, the results included 100 videos with over 47 million viewers. Advocacy was the most prevalent content type at 24% of the total search results. These 100 videos were "shared" a total of 101,173 times and have driven 6,325 subscriptions to distinct YouTube user pages. Of the total videos, 35% were uploaded by or featured an MD/DO/PhD in dermatology or other specialty/field, 2% FNP/PA, 1% RN, and 62% other. As one of the most trafficked global sites on the Internet, YouTube is a valuable resource for dermatologists, physicians in other specialties, and the general public to share their dermatology-related content and gain subscribers. However, challenges of accessing and determining evidence-based data remain an issue.

  8. Hydroforming SRF Three-cell Cavity from Seamless Niobium Tube

    Energy Technology Data Exchange (ETDEWEB)

    Yamanaka, Masashi [KEK, Tsukuba; Dohmae, Takeshi [KEK, Tsukuba; Hocker, Andy [Fermilab; Inoue, Hitoshi [KEK, Tsukuba; Park, Gunn-Tae [KEK, Tsukuba; Tajima, Tsuyoshi [Los Alamos; Umemori, Kensei [KEK, Tsukuba

    2016-06-01

    We are developing the manufacturing method for superconducting radio frequency (SRF) cavities by using a hydroforming instead of using conventional electron beam welding. We expect higher reliability and reduced cost with hydroforming. For successful hydroforming, high-purity seamless niobium tubes with good formability as well as advancing the hydroforming technique are necessary. Using a seamless niobium tube from ATI Wah Chang, we were able to successfully hydroform a 1.3 GHz three-cell TESLA-like cavity and obtained an Eacc of 32 MV/m. A barrel polishing process was omitted after the hydroforming. The vertical test was carried out with very rough inside surface. We got amazing and interesting result.

  9. Dynamics of magnetic flux tubes in an advective flow around a black hole

    Science.gov (United States)

    Deb, Arnab; Giri, Kinsuk; Chakrabarti, Sandip K.

    2017-12-01

    Entangled magnetic fields entering into an accretion flow would very soon be stretched into a dominant toroidal component due to strong differentially rotating motion inside the accretion disc. This is particularly true for weakly viscous, low angular momentum transonic or advective discs. We study the trajectories of toroidal flux tubes inside a geometrically thick flow that undergoes a centrifugal force supported shock. We also study effects of these flux tubes on the dynamics of the inflow and the outflow. We use a finite difference method (total variation diminishing) for this purpose and specifically focused on whether these flux tubes significantly affect the properties of the outflows such as its collimation and the rate. It is seen that depending upon the cross-sectional radius of the flux tubes that control the drag force, these field lines may move towards the central object or oscillate vertically before eventually escaping out of the funnel wall (pressure zero surfaces) along the vertical direction. A comparison of results obtained with and without flux tubes show these flux tubes could play a pivotal role in collimation and acceleration of jets and outflows.

  10. ATLAS muon drift tube production in Seattle

    CERN Document Server

    Zhao, T; Kuykendall, W; Davisson, R

    2004-01-01

    The drift tube production facility that we developed for producing precision drift tubes of the ATLAS forward muon system in our laboratory is described in this paper. The results of quality assurance for approximately 30,000 tube produced are given. Our experience shows that this production facility is very efficient and the quality of produced drift tubes is very high. (2 refs).

  11. 27 CFR 41.35 - Cigarette tubes.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Cigarette tubes. 41.35... OF THE TREASURY (CONTINUED) TOBACCO IMPORTATION OF TOBACCO PRODUCTS, CIGARETTE PAPERS AND TUBES, AND PROCESSED TOBACCO Taxes Tax Rates § 41.35 Cigarette tubes. Cigarette tubes are taxed at the following rates...

  12. 21 CFR 872.6570 - Impression tube.

    Science.gov (United States)

    2010-04-01

    ... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6570 Impression tube. (a) Identification. An impression tube is a device consisting of a hollow copper tube intended to take an impression of a single tooth... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Impression tube. 872.6570 Section 872.6570 Food...

  13. The straw tube tracker of the P¯ANDA experiment

    Science.gov (United States)

    Costanza, S.; Benussi, L.; Braghieri, A.; Boca, G.; Genova, P.; Gianotti, P.; Lavezzi, L.; Lucherini, V.; Montagna, P.; Orecchini, D.; Pierluigi, D.; Ritman, J.; Roeder, M.; Rotondi, A.; Russo, A.; Wintz, P.

    2010-05-01

    P¯ANDA is a new experiment that will be installed at HESR, the new antiproton storage ring under construction as a part of the FAIR facility at Darmstadt, Germany. This experiment, that will investigate QCD in the charmonium mass regime and other aspects of particle and nuclear physics, will be a fixed target detector with a central spectrometer and a forward one. The central tracker will provide information about decay vertices, momenta and types of charged particles emitted after pp¯ annihilations. The design of the Straw Tube Tracker (STT) together with experimental results of the R&D phase are presented here.

  14. Rotating Optical Tubes: An Archimedes' Screw for Atoms

    CERN Document Server

    Rsheed, Anwar Al; Aldossary, Omar M; Lembessis, Vassilis E

    2016-01-01

    The classical dynamics of a cold atom trapped inside a vertical rotating helical optical tube (HOT) is investigated by taking also into account the gravitational field. The resulting equations of motion are solved numerically. The rotation induces a vertical motion for an atom initially at rest. The motion is a result of the action of two inertial forces, namely the centrifugal force and the Coriolis force. Both inertial forces force the atom to rotate in a direction opposite to that of the angular velocity of the HOT. The frequency and the turning points of the atom's global oscillation can be controlled by the value and the direction of the angular velocity of the HOT. However, at large values of the angular velocity of the HOT the atom can escape from the global oscillation and be transported along the axis of the HOT. In this case, the rotating HOT operates as an Optical Archimedes' Screw (OAS) for atoms.

  15. Trade Liberalisation and Vertical Integration

    DEFF Research Database (Denmark)

    Bache, Peter Arendorf; Laugesen, Anders Rosenstand

    producers face decisions on exporting, vertical integration of intermediate-input production, and whether the intermediate-input production should be offshored to a low-wage country. We find that the fractions of final-good producers that pursue either vertical integration, offshoring, or exporting are all......We build a three-country model of international trade in final goods and intermediate inputs and study the relation between four different types of trade liberalisation and vertical integration. Firms are heterogeneous with respect to both productivity and factor (headquarter) intensity. Final-good...... increasing when intermediate-input trade or final-goods trade is liberalised. Finally, we provide guidance for testing the open-economy property rights theory of the firm using firm-level data and surprisingly show that the relationship between factor (headquarter) intensity and the likelihood of vertical...

  16. Horizontal and Vertical Line Designs.

    Science.gov (United States)

    Johns, Pat

    2003-01-01

    Presents an art lesson in which students learn about the artist Piet Mondrian and create their own abstract artworks. Focuses on geometric shapes using horizontal and vertical lines. Includes background information about the artist. (CMK)

  17. Vertical axis wind turbine airfoil

    Science.gov (United States)

    Krivcov, Vladimir; Krivospitski, Vladimir; Maksimov, Vasili; Halstead, Richard; Grahov, Jurij Vasiljevich

    2012-12-18

    A vertical axis wind turbine airfoil is described. The wind turbine airfoil can include a leading edge, a trailing edge, an upper curved surface, a lower curved surface, and a centerline running between the upper surface and the lower surface and from the leading edge to the trailing edge. The airfoil can be configured so that the distance between the centerline and the upper surface is the same as the distance between the centerline and the lower surface at all points along the length of the airfoil. A plurality of such airfoils can be included in a vertical axis wind turbine. These airfoils can be vertically disposed and can rotate about a vertical axis.

  18. The Neutron Spectrum in a Uranium Tube

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E.; Jonsson, E.; Lindberg, M.; Mednis, J.

    1963-10-15

    A series of experimental and theoretical investigations on neutron spectra in lattice cells has been started at the reactor R1. This report gives the results from the first one of these cells - one with a tube of natural -uranium surrounded by heavy water. In the measurements the cell was placed in the central, vertical channel of the reactor. The neutron spectrum from a lead scatterer in the uranium tube - outer diameter 49.2 mm, inner diameter 28.3 mm - was measured with a fast chopper in the energy region 0.01 to 100 eV. Subsidiary measurements indicated that the spectrum in the beam from the lead piece corresponds to the spectrum of the angular flux integrated over all angles. This correspondence is important for the interpretation of the experimental data. The thermal part of the spectrum was found to deviate significantly from a Maxwellian. However, the deviation is not very large, and one could use a Maxwellian, at least to give a rough idea of the hardness of the spectrum. For the present tube the temperature of this Maxwellian was estimated as 90 to 100 deg C above the moderator temperature (33 deg C). In the joining region the rise of the spectrum towards the thermal part is slower than for the cell boundary spectrum, measured earlier. In the epithermal region the limited resolution of the chopper has affected the measurements at the energies of the uranium resonances. However, the shape of the spectrum on the flanks of the first resonance in {sup 238}U (6.68 eV) has been obtained accurately. In the theoretical treatment the THERMOS code with a free gas scattering model has been used. The energy region was 3.06 - 0.00025 eV. The agreement with the measurements is good for the thermal part - possibly the theoretical spectrum is a little softer than the experimental one. In the joining region the results from THERMOS are comparatively high - probably due to the scattering model used.

  19. Physics of magnetic flux tubes

    CERN Document Server

    Ryutova, Margarita

    2015-01-01

    This book is the first account of the physics of magnetic flux tubes from their fundamental properties to collective phenomena in an ensembles of flux tubes. The physics of magnetic flux tubes is absolutely vital for understanding fundamental physical processes in the solar atmosphere shaped and governed by magnetic fields. High-resolution and high cadence observations from recent space and  ground-based instruments taken simultaneously at different heights and temperatures not only show the ubiquity of filamentary structure formation but also allow to study how various events are interconnected by system of magnetic flux tubes. The book covers both theory and observations. Theoretical models presented in analytical and phenomenological forms are tailored for practical applications. These are welded with state-of-the-art observations from early decisive ones to the most recent data that open a new phase-space for exploring the Sun and sun-like stars. Concept of magnetic flux tubes is central to various magn...

  20. Study on Bubbly Two-Phase Flow Across Twisted Tube Bundles Based on Quasi 3D High Speed Video

    OpenAIRE

    Jicheng Zhou; Dongsheng Zhu

    2013-01-01

    In flooded evaporators, refrigerants are boiling outside the tubes. This paper focuses on the bubbly two-phase flow characteristics in twisted tube bundles. The quasi 3-D high speed video method and computational fluid dynamics are carried out to understand the effects which angles between the major axis of the cylinder and vertical direction ( ) and bubble diameters have on the motion behaviours of bubbly flow.  is adjusted to 0°, ...

  1. Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures

    Science.gov (United States)

    Kaul, Anupama B.; Megerian, Krikor G.; Von Allmen, Paul A.; Baron, Richard L.

    2010-01-01

    Plasma-enhanced chemical vapor deposition (PECVD) and high-throughput manufacturing techniques for integrating single, aligned carbon nanotubes (CNTs) into novel 3D nanoscale architectures have been developed. First, the PECVD growth technique ensures excellent alignment of the tubes, since the tubes align in the direction of the electric field in the plasma as they are growing. Second, the tubes generated with this technique are all metallic, so their chirality is predetermined, which is important for electronic applications. Third, a wafer-scale manufacturing process was developed that is high-throughput and low-cost, and yet enables the integration of just single, aligned tubes with nanoscale 3D architectures with unprecedented placement accuracy and does not rely on e-beam lithography. Such techniques should lend themselves to the integration of PECVD grown tubes for applications ranging from interconnects, nanoelectromechanical systems (NEMS), sensors, bioprobes, or other 3D electronic devices. Chemically amplified polyhydroxystyrene-resin-based deep UV resists were used in conjunction with excimer laser-based (lambda = 248 nm) step-and-repeat lithography to form Ni catalyst dots = 300 nm in diameter that nucleated single, vertically aligned tubes with high yield using dc PECVD growth. This is the first time such chemically amplified resists have been used, resulting in the nucleation of single, vertically aligned tubes. In addition, novel 3D nanoscale architectures have been created using topdown techniques that integrate single, vertically aligned tubes. These were enabled by implementing techniques that use deep-UV chemically amplified resists for small-feature-size resolution; optical lithography units that allow unprecedented control over layer-to-layer registration; and ICP (inductively coupled plasma) etching techniques that result in near-vertical, high-aspect-ratio, 3D nanoscale architectures, in conjunction with the use of materials that are

  2. Backward integration, forward integration, and vertical foreclosure

    OpenAIRE

    Spiegel, Yossi

    2013-01-01

    I show that partial vertical integration may either alleviates or exacerbate the concern for vertical foreclosure relative to full vertical integration and I examine its implications for consumer welfare.

  3. Tubing and cable cutting tool

    Science.gov (United States)

    Mcsmith, D. D.; Richardson, J. I. (Inventor)

    1984-01-01

    A hand held hydraulic cutting tool was developed which is particularly useful in deactivating ejection seats in military aircraft rescue operations. The tool consists primarily of a hydraulic system composed of a fluid reservoir, a pumping piston, and an actuator piston. Mechanical cutting jaws are attached to the actuator piston rod. The hydraulic system is controlled by a pump handle. As the pump handle is operated the actuator piston rod is forced outward and thus the cutting jaws are forced together. The frame of the device is a flexible metal tubing which permits easy positioning of the tool cutting jaws in remote and normally inaccessible locations. Bifurcated cutting edges ensure removal of a section of the tubing or cable to thereby reduce the possibility of accidental reactivation of the tubing or cable being severed.

  4. On hydraulics of capillary tubes

    Directory of Open Access Journals (Sweden)

    N.G. Aloyan

    2016-03-01

    Full Text Available The article considers the laws of motion of water in the capillary tubes, taken as a model for flowing well, on the analogical net count device. For capillary tube the lower limit value of flow rate is empirically determined above which the total hydraulic resistance of the capillary is practically constant. The specificity of the phenomenon is that the regime of motion, by a Reynolds number, for a given flow rate still remains laminar. This circumstance can perplex the specialists, so the author invites them to the scientific debate on the subject of study. Obviously, to identify the resulting puzzle it is necessary to conduct a series of experiments using capillaries of different lengths and diameters and with different values of overpressure. The article states that in tubes with very small diameter the preliminary magnitude of capillary rise of water in the presence of flow plays no role and can be neglected.

  5. Drift tubes of Linac 2

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    With the advent of the 800 MeV PS Booster in 1972, the original injector of the PS, a 50 MeV Alvarez-type proton linac, had reached its limits, in terms of intensity and stability. In 1973 one therefore decided to build a new linac (Linac 2), also with a drift-tube Alvarez structure and an energy of 50 MeV. It had a new Cockcroft-Walton preinjector with 750 keV, instead of the previous one with 500 keV. Linac 2 was put into service in 1980. The old Linac 1 was then used for the study of, and later operation with, various types of ions. This picture shows Linac 2 drift-tubes, suspended on stems coming from the top, in contrast to Linac 1, where the drift-tubes stood on stems coming from the bottom.

  6. The pollen tube paradigm revisited.

    Science.gov (United States)

    Kroeger, Jens; Geitmann, Anja

    2012-12-01

    The polar growth process characterizing pollen tube elongation has attracted numerous modeling attempts over the past years. While initial models focused on recreating the correct cellular geometry, recent models are increasingly based on experimentally assessed cellular parameters such as the dynamics of signaling processes and the mechanical properties of the cell wall. Recent modeling attempts have therefore substantially gained in biological relevance and predictive power. Different modeling methods are explained and the power and limitations of individual models are compared. Focus is on several recent models that use closed feedback loops in order to generate limit cycles representing the oscillatory behavior observed in growing tubes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. YouTube and Facebook

    DEFF Research Database (Denmark)

    Robertson, Scott P.; Vatrapu, Ravi; Medina, Richard

    This paper examines the links to YouTube from the Facebook “walls” of Barack Obama, Hillary Clinton, and John McCain over two years prior to the 2008 U.S. Presidential election. User-generated linkage patterns show how participants in these politically-related social networking dialogues used...... online video to make their points. We show a strong integration of the Web 2.0 and new media technologies of social networking and online video. We argue that political discussion in social networking environments can no longer be viewed as primarily textual, and that neither Facebook nor YouTube can...

  8. Working session 3: Tubing integrity

    Energy Technology Data Exchange (ETDEWEB)

    Cueto-Felgueroso, C. [Tecnatom, S.A., San Sebastian de los Reyes, Madrid (Spain); Strosnider, J. [NRC, Washington, DC (United States)

    1997-02-01

    Twenty-three individuals representing nine countries (Belgium, Canada, the Czech Republic, France, Japan, the Slovak Republic, Spain, the UK, and the US) participated in the session on tube integrity. These individuals represented utilities, vendors, consultants and regulatory authorities. The major subjects discussed by the group included overall objectives of managing steam generator tube degradation, necessary elements of a steam generator degradation management program, the concept of degradation specific management, structural integrity evaluations, leakage evaluations, and specific degradation mechanisms. The group`s discussions on these subjects, including conclusions and recommendations, are summarized in this article.

  9. Orifice plates and venturi tubes

    CERN Document Server

    Reader-Harris, Michael

    2015-01-01

    This book gives the background to differential-pressure flow measurement and goes through the requirements explaining the reason for them. For those who want to use an orifice plate or a Venturi tube the standard ISO 5167 and its associated Technical Reports give the instructions required.  However, they rarely tell the users why they should follow certain instructions.  This book helps users of the ISO standards for orifice plates and Venturi tubes to understand the reasons why the standards are as they are, to apply them effectively, and to understand the consequences of deviations from the standards.

  10. Biocompatibility of Different Nerve Tubes

    Directory of Open Access Journals (Sweden)

    Hisham Fansa

    2009-09-01

    Full Text Available Bridging nerve gaps with suitable grafts is a major clinical problem. The autologous nerve graft is considered to be the gold standard, providing the best functional results; however, donor site morbidity is still a major disadvantage. Various attempts have been made to overcome the problems of autologous nerve grafts with artificial nerve tubes, which are “ready-to-use” in almost every situation. A wide range of materials have been used in animal models but only few have been applied to date clinically, where biocompatibility is an inevitable prerequisite. This review gives an idea about artificial nerve tubes with special focus on their biocompatibility in animals and humans.

  11. Pump element for a tube pump

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a tube pump comprising a tube and a pump element inserted in the tube, where the pump element comprises a rod element and a first and a second non-return valve member positioned a distance apart on the rod element. The valve members are oriented in the same direction...... portion acts to alternately close and open the valve members thereby generating a fluid flow through the tube. The invention further relates to a pump element comprising at least two non-return valve members connected by a rod element, and for insertion in an at least partly flexible tube in such tube...... pump as mentioned above, thereby acting to generate a fluid flow through the tube upon repeated deformation of the tube between the two valve members. The pump element may comprise a connecting part for coupling to another tube and may comprise a sealing part establishing a fluid tight connection...

  12. A Built for Purpose Micro-Hole Coiled Tubing Rig (MCTR)

    Energy Technology Data Exchange (ETDEWEB)

    Bart Patton

    2007-09-30

    This report will serve as the final report on the work performed from the contract period October 2005 thru April 2007. The project 'A Built for Purpose Microhole Coiled Tubing Rig (MCTR)' purpose was to upgrade an existing state-of-the-art Coiled Tubing Drilling Rig to a Microhole Coiled Tubing Rig (MCTR) capable of meeting the specifications and tasks of the Department of Energy. The individual tasks outlined to meet the Department of Energy's specifications are: (1) Concept and development of lubricator and tool deployment system; (2) Concept and development of process control and data acquisition; (3) Concept and development of safety and efficiency improvements; and (4) Final unit integration and testing. The end result of the MCTR upgrade has produced a unit capable of meeting the following requirements: (1) Capable of handling 1-inch through 2-3/8-inch coiled tubing (Currently dressed for 2-3/8-inch coiled tubing and capable of running up to 3-1/2-inch coiled tubing); (2) Capable of drilling and casing surface, intermediate, production and liner hole intervals; (3) Capable of drilling with coiled tubing and has all controls and installation piping for a top drive; (4) Rig is capable of running 7-5/8-inch range 2 casing; and (5) Capable of drilling 5,000 ft true vertical depth (TVD) and 6,000 ft true measured depth (TMD).

  13. A tube seepage meter for in situ measurement of seepage rate and groundwater sampling

    Science.gov (United States)

    Solder, John; Gilmore, Troy E.; Genereux, David P.; Solomon, D. Kip

    2016-01-01

    We designed and evaluated a “tube seepage meter” for point measurements of vertical seepage rates (q), collecting groundwater samples, and estimating vertical hydraulic conductivity (K) in streambeds. Laboratory testing in artificial streambeds show that seepage rates from the tube seepage meter agreed well with expected values. Results of field testing of the tube seepage meter in a sandy-bottom stream with a mean seepage rate of about 0.5 m/day agreed well with Darcian estimates (vertical hydraulic conductivity times head gradient) when averaged over multiple measurements. The uncertainties in q and K were evaluated with a Monte Carlo method and are typically 20% and 60%, respectively, for field data, and depend on the magnitude of the hydraulic gradient and the uncertainty in head measurements. The primary advantages of the tube seepage meter are its small footprint, concurrent and colocated assessments of q and K, and that it can also be configured as a self-purging groundwater-sampling device.

  14. Vertical saccades in dyslexic children.

    Science.gov (United States)

    Tiadi, Aimé; Seassau, Magali; Bui-Quoc, Emmanuel; Gerard, Christophe-Loïc; Bucci, Maria Pia

    2014-11-01

    Vertical saccades have never been studied in dyslexic children. We examined vertical visually guided saccades in fifty-six dyslexic children (mean age: 10.5±2.56 years old) and fifty-six age matched non dyslexic children (mean age: 10.3±1.74 years old). Binocular eye movements were recorded using an infrared video-oculography system (mobileEBT®, e(ye)BRAIN). Dyslexic children showed significantly longer latency than the non dyslexic group, also the occurrence of anticipatory and express saccades was more important in dyslexic than in non dyslexic children. The gain and the mean velocity values were significantly smaller in dyslexic than in non dyslexic children. Finally, the up-down asymmetry reported in normal population for the gain and the velocity of vertical saccades was observed in dyslexic children and interestingly, dyslexic children also reported an up-down asymmetry for the mean latency. Taken together all these findings suggested impairment in cortical areas responsible of vertical saccades performance and also at peripheral level of the extra-ocular oblique muscles; moreover, a visuo-attentionnal bias could explain the up-down asymmetry reported for the vertical saccade triggering. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Thermal inhomogeneities in vortex tubes

    Science.gov (United States)

    Lemesh, N. I.; Senchuk, L. A.

    An experimental study of the effect of the temperature of the inlet gas on the temperature difference between the hot and cold streams discharged from a Ranque-Hilsch vortex tube is described. The experimental results are presented in graphical form. It is that the temperature difference increases with the temperature of the entering gas.

  16. Working session 1: Tubing degradation

    Energy Technology Data Exchange (ETDEWEB)

    Kharshafdjian, G. [Atomic Energy of Canada, Mississauga, Ontario (Canada); Turluer, G. [IPSN, Fontenay-aux-Roses (France)

    1997-02-01

    A general introductory overview of the purpose of the group and the general subject area of SG tubing degradation was given by the facilitator. The purpose of the session was described as to {open_quotes}develop conclusions and proposals on regulatory and technical needs required to deal with the issues of SG tubing degradation.{close_quotes} Types, locations and characteristics of tubing degradation in steam generators were briefly reviewed. The well-known synergistic effects of materials, environment, and stress and strain/strain rate, subsequently referred to by the acronym {open_quotes}MESS{close_quotes} by some of the group members, were noted. The element of time (i.e., evolution of these variables with time) was emphasized. It was also suggested that the group might want to consider the related topics of inspection capabilities, operational variables, degradation remedies, and validity of test data, and some background information in these areas was provided. The presentation given by Peter Millet during the Plenary Session was reviewed; Specifically, the chemical aspects and the degradation from the secondary side of the steam generator were noted. The main issues discussed during the October 1995 EPRI meeting on secondary side corrosion were reported, and a listing of the potential SG tube degradations was provided and discussed.

  17. Kundt's Tube Experiment Using Smartphones

    Science.gov (United States)

    Parolin, Sara Orsola; Pezzi, Giovanni

    2015-01-01

    This article deals with a modern version of Kundt's tube experiment. Using economic instruments and a couple of smartphones, it is possible to "see" nodes and antinodes of standing acoustic waves in a column of vibrating air and to measure the speed of sound.

  18. Vitamins and neural tube defects

    OpenAIRE

    Harris, Rodney

    1988-01-01

    The use of vitamin supplements by women around the time of conception was examined and compared in those having babies with neural tube defects, those with still births or some other type of malformation, and in women who had normal babies.

  19. OurTube / David Talbot

    Index Scriptorium Estoniae

    Talbot, David

    2009-01-01

    USA California Ülikooli töötajate Abram Stern'i ja Michael Dale'i poolt 2005. a. algatatud USA kongressis peetud kõnede videoremiksidest ja nende poolt loodud veebisaidist Metavid.org. Ka YouTube keskkonnast ja wikipedia katsetustest muuta oma keskkond multimeedialisemaks

  20. Fin-tube solar collectors

    Science.gov (United States)

    1980-01-01

    Report presents test procedures and results of thermal-performance evaluation of seven commercial fin tube (liquid) solar collector-absorber plates. Tests were conducted indoors at Marshall Space Flight Center Solar simulator. Results are graphically shown along with supporting test data and summary, indicating efficiency as function of collector inlet temperature.

  1. Tube Suction Test for Evaluating

    Science.gov (United States)

    2012-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...

  2. Building your own shock tube

    NARCIS (Netherlands)

    J. Naber (Jorick)

    2005-01-01

    textabstractThis report treats the development of a shock tube solver for the simulation of flows described by the one-dimensional Euler equations. A well-known one-dimensional flow problem is the initial Riemann problem, which treats the development of a flow due to two initially separated

  3. Welding the CNGS decay tube

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    3.6 km of welds were required for the 1 km long CERN Neutrinos to Gran Sasso (CNGS) decay tube, in which particles produced in the collision with a proton and a graphite target will decay into muons and muon neutrinos. Four highly skilled welders performed this delicate task.

  4. Finned double-tube PCM system as a waste heat storage

    Science.gov (United States)

    Alhamdo, M. H.; Theeb, M. A.; Golam, A. S.

    2015-11-01

    In this work, focus is taken on developing a waste heat recovery system for capturing potential of exhaust heat from an air conditioner unit to be reused later. This system has the ability to store heat in phase change material (PCM) and then release it to a discharge water system when required. To achieve this goal, a system of Finned, Water-PCM, Double tube (FWD) has been developed and tested. Different profiles of fins attached to the (FWD) system have been investigated for increasing the thermal conductivity of the PCM. These include using Circular Finned, Water-PCM, Double tube (CFWD) system; Longitudinal Finned, Water-PCM, Double tube (LFWD) system; Spiral Finned, Water-PCM, Double tube (SFWD) system; as well as; Without Fins, Water-PCM, Double tube (WFWD) system. An experimental test rig that attached to an air-conditioner unit has been built to include 32- tubes of the FWD systems for both vertical and horizontal layouts during charging and water discharging processes. Results show a significant performance improvement when using spiral and circular fins during charging process at vertical position. However, longitudinal and without fins showed better performance in horizontal position. Overall, the developed SFWD system in vertical position has been found to exhibit the most effective type due to the fastest PCM melting and solidification. As compared to the WFWD system, the FWD systems have been found to increase the PCM temperature gain of about 15.3% for SFWD system; 8.2% for CFWD; and 4.3% for LFWD system.

  5. Schizophrenia on YouTube.

    Science.gov (United States)

    Nour, Matthew M; Nour, Murraih H; Tsatalou, Olga-Maria; Barrera, Alvaro

    2017-01-01

    YouTube ( www.youtube.com ) is the most popular video-sharing Web site on the Internet and is used by medical students as a source of information regarding mental health conditions, including schizophrenia. The accuracy and educational utility of schizophrenia presentations on YouTube are unknown. The purpose of this study was to analyze the accuracy of depictions of psychosis in the context of a diagnosis of schizophrenia (referred to in this article as "acute schizophrenia") on YouTube and to assess the utility of these videos as educational tools for teaching medical students to recognize the clinical features of acute schizophrenia. YouTube was searched for videos purporting to show acute schizophrenia. Eligible videos were independently rated by two consultant psychiatrists on two separate occasions 22 days apart for diagnostic accuracy, psychopathology, and educational utility. Videos (N=4,200) were assessed against predefined inclusion and exclusion criteria. The majority were not eligible for further analysis, mostly because they did not claim to show a patient with schizophrenia (74%) or contained duplicated content (11%). Of 35 videos that met the eligibility and adequacy criteria, only 12 accurately depicted acute schizophrenia. Accurate videos were characterized by persecutory delusions (83%), inappropriate affect (75%), and negative symptoms (83%). Despite the fact that 83% of accurate videos were deemed to have good educational utility compared with 15% of inaccurate videos, accurate and inaccurate videos had similar view counts (290,048 versus 186,124). Schizophrenia presentations on YouTube offer a distorted picture of the condition.

  6. A case of a 'lost' nasogastric tube.

    Science.gov (United States)

    Sankar, V; Shakeel, M; Keh, S; Ah-See, K W

    2012-12-01

    To present the case of a 'lost' nasogastric tube and to highlight the importance of imaging and/or chest X-ray after nasogastric tube insertion, especially in unreliable patients. A 50-year-old man, undergoing radiotherapy treatment for squamous cell carcinoma of the tongue base, was admitted for pain control and nasogastric tube feeding. This patient required multiple nasogastric tubes over a two-week period. The patient repeatedly denied pulling the nasogastric tube out and we were unable to establish the exact mode of nasogastric tube removal. On one such occasion another tube was inserted and a check X-ray showed two feeding tubes; the latest one was lying in the left main bronchus and the old nasogastric tube was observed in the oesophagus, with its upper end jutting above the hypopharynx. It was apparent that the patient had somehow cut the tube and swallowed it. This case not only illustrates the importance of flexible nasendoscopy and/or chest X-ray for checking the position of the nasogastric tube, but also highlights that some patients are not tolerant of nasogastric tubes. The use of nasogastric tubes should be avoided in these patients to prevent any self-inflicted injury.

  7. Waves, circulation and vertical dependence

    Science.gov (United States)

    Mellor, George

    2013-04-01

    Longuet-Higgins and Stewart (J Fluid Mech 13:481-504, 1962; Deep-Sea Res 11:529-562, 1964) and later Phillips (1977) introduced the problem of waves incident on a beach, from deep to shallow water. From the wave energy equation and the vertically integrated continuity equation, they inferred velocities to be Stokes drift plus a return current so that the vertical integral of the combined velocities was nil. As a consequence, it can be shown that velocities of the order of Stokes drift rendered the advective term in the momentum equation negligible resulting in a simple balance between the horizontal gradients of the vertically integrated elevation and wave radiation stress terms; the latter was first derived by Longuet-Higgins and Stewart. Mellor (J Phys Oceanogr 33:1978-1989, 2003a), noting that vertically integrated continuity and momentum equations were not able to deal with three-dimensional numerical or analytical ocean models, derived a vertically dependent theory of wave-circulation interaction. It has since been partially revised and the revisions are reviewed here. The theory is comprised of the conventional, three-dimensional, continuity and momentum equations plus a vertically distributed, wave radiation stress term. When applied to the problem of waves incident on a beach with essentially zero turbulence momentum mixing, velocities are very large and the simple balance between elevation and radiation stress gradients no longer prevails. However, when turbulence mixing is reinstated, the vertically dependent radiation stresses produce vertical velocity gradients which then produce turbulent mixing; as a consequence, velocities are reduced, but are still larger by an order of magnitude compared to Stokes drift. Nevertheless, the velocity reduction is sufficient so that elevation set-down obtained from a balance between elevation gradient and radiation stress gradients is nearly coincident with that obtained by the aforementioned papers. This paper

  8. Tracking with Straw Tubes in the barP ANDA Experiment

    Science.gov (United States)

    Gianotti, P.; Lucherini, V.; Pace, E.; Kozlov, K.; Ohm, H.; Orfanitski, S.; Mertens, M.; Ritman, J.; Roeder, M.; Serdyuk, V.; Wintz, P.; Ldzik, M.; Przyborowski, D.; Jowzaee, S.; Kajetanowicz, M.; Korcyl, G.; Salabura, P.; Smyrski, J.; Kulessa, P.; Pysz, K.; Boca, G.; Costanza, S.; Lavezzi, L.; Montagna, P.; Rotondi, A.; Savrié, M.; Levitskaya, O.; Kashchuk, A.

    2012-08-01

    Tracking charged particles is one of the essential tasks of the barP ANDA ex periment, providing information about primary and secondary decay vertices, momenta and types of charged particles emitted after antiproton-proton annihilation. Different tracking devices are under construction for the barP ANDA spectrometer and among them the two straw tube trackers. A new technique, based on the use of straw tubes operated at over-pressure has been adopted allowing the construction of self-supporting modules avoiding heavy mechanical frames.

  9. Fulfilling Magnetostatic Conditions in Numerical Simulations of Expanding Flux Tubes

    Science.gov (United States)

    Utz, D.; Van Doorsselaere, T.; Kühner, O.; Magyar, N.; Calvo Santamaria, I.; Campos Rozo, J. I.

    A long-lasting problem of solar physics is the topic of the heating of the outer atmospheric layers of the Sun. Among the possible heating scenarios are wave driven heating processes. In this scenario disturbances and turbulence in the photosphere of the Sun causes the creation of waves which propagate upwards into the higher atmosphere where these waves are at least partially damped and absorbed, causing heating of the atmosphere. Nowadays it is thought that especially MHD waves play an important role in such heating scenarios. The created MHD waves are guided especially well along strong vertical magnetic field configurations, so-called flux-tubes, into the higher atmosphere. To obtain deeper insights into this fascinating topic, numerical simulations are a useful tool at hand. However, up to now it is still quite common to assume simple non stratified flux tubes which feature in addition weak magnetic field strengths. While this makes the modeling of the solar atmosphere and the magnetic field configuration much easier, the results might be changed drastically by these simplifications. In the current contribution we wish to outline a method of how to construct self-consistent, magneto-static flux tube atmospheres.

  10. Small bore ceramic laser tube inspection light table

    Science.gov (United States)

    Updike, Earl O.

    1990-01-01

    Apparatus for inspecting small bore ceramic laser tubes, which includes a support base with one or more support rollers. A fluorescent light tube is inserted within the laser tube and the laser tube is supported by the support rollers so that a gap is maintained between the laser tube and the fluorescent tube to enable rotation of the laser tube. In operation, the ceramic tube is illuminated from the inside by the fluorescent tube to facilitate visual inspection. Centering the tube around the axial light of the fluorescent tube provides information about straightness and wall thickness of the laser tube itself.

  11. The accessory fallopian tube: A rare anomaly

    Directory of Open Access Journals (Sweden)

    Kusum R Gandhi

    2012-01-01

    Full Text Available This paper presents a rare anatomical variation in the form of accessory fallopian tube on right side. The duplication of fallopian tube was observed in a 34-year-old female during routine undergraduate dissection in our department. Fallopian tube is the part of uterus that carries the ovum from the ovary to the uterus. Accessory fallopian tube is the congenital anomaly attached to the ampullary part of main tube. This accessory tube is common site of pyosalpinx, hydrosalpinx, cystic swelling and torsion. The ovum released by the ovary may also be captured by the blind accessory tube leading to infertility or ectopic pregnancy. Hence, all patients of infertility or pelvic inflammatory disease should be screened to rule out the presence of accessory fallopian tube and if encountered should be removed.

  12. Models for Automated Tube Performance Calculations

    Energy Technology Data Exchange (ETDEWEB)

    C. Brunkhorst

    2002-12-12

    High power radio-frequency systems, as typically used in fusion research devices, utilize vacuum tubes. Evaluation of vacuum tube performance involves data taken from tube operating curves. The acquisition of data from such graphical sources is a tedious process. A simple modeling method is presented that will provide values of tube currents for a given set of element voltages. These models may be used as subroutines in iterative solutions of amplifier operating conditions for a specific loading impedance.

  13. Hybrid Vertical-Cavity Laser

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention provides a light source (2) for light circuits on a silicon platform (3). A vertical laser cavity is formed by a gain region (101) arranged between a top mirror (4) and a bottom grating-mirror (12) in a grating region (11) in a silicon layer (10) on a substrate. A waveguide...

  14. Physics and the Vertical Jump

    Science.gov (United States)

    Offenbacher, Elmer L.

    1970-01-01

    The physics of vertical jumping is described as an interesting illustration for motivating students in a general physics course to master the kinematics and dynamics of one dimensional motion. The author suggests that mastery of the physical principles of the jump may promote understanding of certain biological phenomena, aspects of physical…

  15. Multiservice Vertical Handoff Decision Algorithms

    Directory of Open Access Journals (Sweden)

    Zhu Fang

    2006-01-01

    Full Text Available Future wireless networks must be able to coordinate services within a diverse-network environment. One of the challenging problems for coordination is vertical handoff, which is the decision for a mobile node to handoff between different types of networks. While traditional handoff is based on received signal strength comparisons, vertical handoff must evaluate additional factors, such as monetary cost, offered services, network conditions, and user preferences. In this paper, several optimizations are proposed for the execution of vertical handoff decision algorithms, with the goal of maximizing the quality of service experienced by each user. First, the concept of policy-based handoffs is discussed. Then, a multiservice vertical handoff decision algorithm (MUSE-VDA and cost function are introduced to judge target networks based on a variety of user- and network-valued metrics. Finally, a performance analysis demonstrates that significant gains in the ability to satisfy user requests for multiple simultaneous services and a more efficient use of resources can be achieved from the MUSE-VDA optimizations.

  16. Insta-Head: An Instant Headgear Tube

    Directory of Open Access Journals (Sweden)

    Rajesh B Kuril

    2011-01-01

    Full Text Available Specialized headgear tubes are required for fabrication of appliances, such as activator-headgear and twin-block with headgear. The common problems with these tubes are that they need to be purchased beforehand and they are expensive. The present article describes the chairside fabrication of a simple, inexpensive headgear tube (insta-head without the need of any specialized armamentarium.

  17. A Novel Mediastinal Drainage Tube for Mediastinitis

    Directory of Open Access Journals (Sweden)

    Jun Ho Yhang

    2015-10-01

    Full Text Available Mediastinitis is a life-threatening disease, and effective drainage is needed to treat mediastinitis with abscess formation. We recommend an alternative drainage method using chest tube binding with a Silastic Penrose drainage tube. The use of a Silastic Penrose drainage tube may help to manage mediastinitis with abscess formation. This method facilitates effective draining and prevents tissue adhesion.

  18. Studies of Degraded Smelt Spout Opening Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Keiser, James R [ORNL; Kish, Joseph R. [Paprican; Willoughby, Adam W [ORNL; Longmire, Hu Foster [ORNL; Singbeil, Douglas [Paprican

    2007-01-01

    Co-extruded type 304L stainless steel/SA210 carbon steel tubes have been used on the floors and lower walls of many black liquor recovery boilers to address the wall thinning problem that had been an issue for boiler owners and operators. Use of these tubes greatly reduced the corrosion issue, but corrosion was still sometimes observed and cracking was discovered in some tubes, particularly those that are bent to form the openings for smelt spouts. Because cracks in the opening tubes were sometimes observed to extend a significant distance into the tube wall and because these cracks were found fairly frequently, tubes made from a number of alternate cladding materials were tried in place of the 304L clad opening tubes. This paper describes the results of examinations of spout opening tubes of the standard 304L/carbon steel and of several of the alternate materials that have been tried. In addition to the corrosion and cracking seen in the spout opening tubes, another issue associated with these tubes has been observed. Preferential corrosion of the cap welds is sometimes seen on butt welds attaching the spout opening tubes made with alternate cladding materials to the standard 304L/carbon steel co-extruded wall tubes. Some information on the observations of this corrosion is also included in this paper.

  19. Radioactive fallout and neural tube defects

    African Journals Online (AJOL)

    Nejat Akar

    2015-07-10

    Jul 10, 2015 ... Neural tube defects;. Anencephaly;. Spina bifida. Abstract Possible link between radioactivity and the occurrence of neural tube defects is a long lasting debate ... Neural tube defects, are one of the common congenital mal- formations ... ent cities of Turkey (˙Izmir/Aegean Region; Trabzon/Black Sea region ...

  20. Clinical Burden of Laparoscopic Feeding Jejunostomy Tubes.

    Science.gov (United States)

    Speer, Emily A; Chow, Simon C; Dunst, Christy M; Shada, Amber L; Halpin, Valerie; Reavis, Kevin M; Cassera, Maria; Swanström, Lee L

    2016-05-01

    Feeding jejunostomies (J tubes) provide enteral nutrition when oral and gastric routes are not options. Despite their prevalence, there is a paucity of literature regarding their efficacy and clinical burden. All laparoscopic J tubes placed over a 5-year period were retrospectively reviewed. Clinical burden was measured by number of clinical contact events (tube-related clinic visits, phone calls, ED visits) and morbidity (dislodgement, clogging, tube fracture, infection, other). Tube replacements were also recorded. One hundred fifty-one patients were included. Fifty-nine percent had associated malignancy, and 35 % were placed for nutritional prophylaxis. Mean time to J tube removal was 146 days. J tubes were expected to be temporary in >90 % but only 50 % had sufficient oral intake for removal. Tubes were removed prematurely due to patient intolerance in 8 %. Mortality was 0 %. Morbidity was 51 % and included clogging (12 %), tube fracture (16 %), dislodgement (25 %), infection (18 %) and "other" (leaking, erosion, etc.) in 17 %. The median number of adverse events per J tube was 2(0-8). Mean number of clinic phone calls was 2.5(0-22), ED visits 0.5(0-7), and clinic visits 1.4(0-13), with 82 % requiring more than one J tube-related clinic visit. Unplanned replacements occurred in 40 %. While necessary for some patients, J tubes are associated with high clinical burden.

  1. Roll-forming tubes to header plates

    Science.gov (United States)

    Kramer, K.

    1976-01-01

    Technique has been developed for attaching and sealing tubes to header plates using a unique roll-forming tool. Technique is useful for attaching small tubes which are difficult to roll into conventional grooves in header plate tube holes, and for attaching when welding, brazing, or soldering is not desirable.

  2. The Fuge Tube Diode Array Spectrophotometer

    Science.gov (United States)

    Arneson, B. T.; Long, S. R.; Stewart, K. K.; Lagowski, J. J.

    2008-01-01

    We present the details for adapting a diode array UV-vis spectrophotometer to incorporate the use of polypropylene microcentrifuge tubes--fuge tubes--as cuvettes. Optical data are presented validating that the polyethylene fuge tubes are equivalent to the standard square cross section polystyrene or glass cuvettes generally used in…

  3. Kundt's Tube: An Acoustic Gas Analyzer

    Science.gov (United States)

    Aristov, Natasha; Habekost, Gehsa; Habekost, Achim

    2011-01-01

    A Kundt tube is normally used to measure the speed of sound in gases. Therefore, from known speeds of sound, a Kundt tube can be used to identify gases and their fractions in mixtures. In these experiments, the speed of sound is determined by measuring the frequency of a standing sound wave at a fixed tube length, temperature, and pressure. This…

  4. Spring/dimple instrument tube restraint

    Science.gov (United States)

    DeMario, Edmund E.; Lawson, Charles N.

    1993-01-01

    A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs.

  5. Numerical and experimental study of an annular pulse tube used in the pulse tube cooler

    Science.gov (United States)

    Pang, Xiaomin; Chen, Yanyan; Wang, Xiaotao; Dai, Wei; Luo, Ercang

    2017-12-01

    Multi-stage pulse tube coolers normally use a U-type configuration. For compactness, it is attractive to build a completely co-axial multi-stage pulse tube cooler. In this way, an annular shape pulse tube is inevitable. Although there are a few reports about previous annular pulse tubes, a detailed study and comparison with a circular pulse tube is lacking. In this paper, a numeric model based on CFD software is carried out to compare the annular pulse tube and circular pulse tube used in a single stage in-line type pulse tube cooler with about 10 W of cooling power at 77 K. The length and cross sectional area of the two pulse tubes are kept the same. Simulation results show that the enthalpy flow in the annular pulse tube is lower by 1.6 W (about 11% of the enthalpy flow) compared to that in circular pulse tube. Flow and temperature distribution characteristics are also analyzed in detail. Experiments are then conducted for comparison with an in-line type pulse tube cooler. With the same acoustic power input, the pulse tube cooler with a circular pulse tube obtains 7.88 W of cooling power at 77 K, while using an annular pulse tube leads to a cooling power of 7.01 W, a decrease of 0.9 W (11.4%) on the cooling performance. The study sets the basis for building a completely co-axial two-stage pulse tube cooler.

  6. ATLS: Catheter and tube placement

    Science.gov (United States)

    Gosbee, John; Krupa, Debra T.; Pepper, L.; Orsak, Debra

    1991-01-01

    The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.

  7. AFRL Ludwieg Tube Initial Performance

    Science.gov (United States)

    2017-11-01

    controls the fill and purge process. A commercial Sylvania 18 kW resistance heater raises the inlet air temperature to 500K prior to filling the...Distribution is unlimited. 3 ms of uniform run conditions between wave passages. The exterior of the driver tube is heated with blanket resistance ...uniformity and noise characteristics, this has not been a major problem with wind tunnels using this type of valve. However, there has been no direct

  8. Experimental investigation of the effect vertical oscillation on the heat transfer coefficient of the finned tube

    Directory of Open Access Journals (Sweden)

    Kadhim S. K.

    2016-01-01

    Full Text Available The aim of this work is to investigate experimentally the effect of the forced vibrations on the free convection heat transfer coefficient using heated longitudinally finned cylinder made of Aluminium. The effect of the vibration frequency ranged from 2 to16 Hz with various heat fluxes ranged from 500-1500 W/m2. It was found that, the relation between the heat transfer coefficient and amplitude of vibration increased for all inclination angles from (0°-45°, while the increment of inclination angle decreases the values of convection heat transfer coefficient. The results show that the heat transfer coefficient ratio (hv/ho of longitudinal finned cylinders in (0° angle was (8% and (30% greater than those for the (30° and (45° respectively.

  9. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  10. Stability of coaxial jets confined in a tube with heat and mass transfer

    Science.gov (United States)

    Mohanta, Lokanath; Cheung, Fan-Bill; Bajorek, Stephen M.

    2016-02-01

    A linear temporal stability of coaxial confined jets in a vertical tube involving heat and mass transfer at the interface is presented in this paper. A potential flow analysis that includes the effect of viscosity at the interface is performed in analyzing the stability of the system. Film boiling in a vertical tube gives rise to the flow configuration explored in this work. The effects of various non-dimensional parameters on the growth rate and the neutral curve are discussed. The heat transfer at the interface has been characterized by introducing a heat flux ratio between the conduction heat flux and the evaporation heat flux. Viscous forces and the heat and mass transfer at the interface are found to stabilize the flow both in the capillary instability region and Kelvin-Helmholtz instability region. Increasing heat and mass transfer at the interface stabilizes the flow to small as well as very large wave numbers.

  11. The stretching of magnetic flux tubes in the convective overshoot region

    Science.gov (United States)

    Fisher, George H.; McClymont, Alexander N.; Chou, Dean-Yi

    1991-06-01

    The present study examines the fate of a magnetic flux tube initially lying at the bottom of the solar convective overshoot region. Stretching of the flux tube, e.g., by differential rotation, reduces its density, causing it to rise quasi-statically (a process referred to as vertical flux drift) until it reaches the top of the overshoot region and enters the buoyantly unstable convection region, from which a portion of it may ultimately protrude to form an active region on the surface. It is suggested that vertical flux drift and flux destabilization are inevitable consequences of field amplification, and it is surmised that these phenomena should be considered in self-consistent models of solar and stellar dynamos operating in the overshoot region.

  12. Gastroenteric tube feeding: Techniques, problems and solutions

    Science.gov (United States)

    Blumenstein, Irina; Shastri, Yogesh M; Stein, Jürgen

    2014-01-01

    Gastroenteric tube feeding plays a major role in the management of patients with poor voluntary intake, chronic neurological or mechanical dysphagia or gut dysfunction, and patients who are critically ill. However, despite the benefits and widespread use of enteral tube feeding, some patients experience complications. This review aims to discuss and compare current knowledge regarding the clinical application of enteral tube feeding, together with associated complications and special aspects. We conducted an extensive literature search on PubMed, Embase and Medline using index terms relating to enteral access, enteral feeding/nutrition, tube feeding, percutaneous endoscopic gastrostomy/jejunostomy, endoscopic nasoenteric tube, nasogastric tube, and refeeding syndrome. The literature showed common routes of enteral access to include nasoenteral tube, gastrostomy and jejunostomy, while complications fall into four major categories: mechanical, e.g., tube blockage or removal; gastrointestinal, e.g., diarrhea; infectious e.g., aspiration pneumonia, tube site infection; and metabolic, e.g., refeeding syndrome, hyperglycemia. Although the type and frequency of complications arising from tube feeding vary considerably according to the chosen access route, gastrointestinal complications are without doubt the most common. Complications associated with enteral tube feeding can be reduced by careful observance of guidelines, including those related to food composition, administration rate, portion size, food temperature and patient supervision. PMID:25024606

  13. Development boiling to sprinkled tube bundle

    Directory of Open Access Journals (Sweden)

    Kracík Petr

    2016-01-01

    Full Text Available This paper presents results of a studied heat transfer coefficient at the surface of a sprinkled tube bundle where boiling occurs. Research in the area of sprinkled exchangers can be divided into two major parts. The first part is research on heat transfer and determination of the heat transfer coefficient at sprinkled tube bundles for various liquids, whether boiling or not. The second part is testing of sprinkle modes for various tube diameters, tube pitches and tube materials and determination of individual modes’ interface. All results published so far for water as the falling film liquid apply to one to three tubes for which the mentioned relations studied are determined in rigid laboratory conditions defined strictly in advance. The sprinkled tubes were not viewed from the operational perspective where there are more tubes and various modes may occur in different parts with various heat transfer values. The article focuses on these processes. The tube is located in a low-pressure chamber where vacuum is generated using an exhauster via ejector. The tube consists of smooth copper tubes of 12 mm diameter placed horizontally one above another.

  14. Mathematical modelling of thermal and flow processes in vertical ground heat exchangers

    Directory of Open Access Journals (Sweden)

    Pater Sebastian

    2017-12-01

    Full Text Available The main task of mathematical modelling of thermal and flow processes in vertical ground heat exchanger (BHE-Borehole Heat Exchanger is to determine the unit of borehole depth heat flux obtainable or transferred during the operation of the installation. This assignment is indirectly associated with finding the circulating fluid temperature flowing out from the U-tube at a given inlet temperature of fluid in respect to other operational parameters of the installation.

  15. Characterization of Vertical Impact Device Acceleration Pulses Using Parametric Assessment: Phase I

    Science.gov (United States)

    2015-04-01

    Vertical Impact Device (VID). The VID is a Monterey Research Laboratory IMPAC3636 high-G impact test machine with seismic suspension , and is currently...nitrogen and oil suspension system. Programmers are used to control the shape, peak acceleration, and duration of the shock pulse. The...cable, pulley, and lifting tube driven by one hydraulic cylinder, for each of the two side supports. Pneumatic friction brakes in the carriage assembly

  16. Coexistence of Strategic Vertical Separation and Integration

    DEFF Research Database (Denmark)

    Jansen, Jos

    2003-01-01

    This paper gives conditions under which vertical separation is chosen by some upstream firms, while vertical integration is chosen by others in the equilibrium of a symmetric model. A vertically separating firm trades off fixed contracting costs against the strategic benefit of writing a (two......-part tariff, exclusive dealing) contract with its retailer. Coexistence emerges when more than two vertical Cournot oligopolists supply close substitutes. When vertical integration and separation coexist, welfare could be improved by reducing the number of vertically separating firms. The scope...

  17. Kinematic Fitting of Detached Vertices

    Energy Technology Data Exchange (ETDEWEB)

    Mattione, Paul [Rice Univ., Houston, TX (United States)

    2007-05-01

    The eg3 experiment at the Jefferson Lab CLAS detector aims to determine the existence of the $\\Xi_{5}$ pentaquarks and investigate the excited $\\Xi$ states. Specifically, the exotic $\\Xi_{5}^{--}$ pentaquark will be sought by first reconstructing the $\\Xi^{-}$ particle through its weak decays, $\\Xi^{-}\\to\\pi^{-}\\Lambda$ and $\\Lambda\\to\\pi^{-}$. A kinematic fitting routine was developed to reconstruct the detached vertices of these decays, where confidence level cuts on the fits are used to remove background events. Prior to fitting these decays, the exclusive reaction $\\gamma D\\rightarrow pp\\pi^{-}$ was studied in order to correct the track measurements and covariance matrices of the charged particles. The $\\Lambda\\rightarrow p\\pi^{-}$ and $\\Xi^{-}\\to\\pi^{-}\\Lambda$ decays were then investigated to demonstrate that the kinematic fitting routine reconstructs the decaying particles and their detached vertices correctly.

  18. Vertical distribution of Arctic methane

    Science.gov (United States)

    Tukiainen, Simo; Karppinen, Tomi; Hakkarainen, Janne; Kivi, Rigel; Heikkinen, Pauli; Tamminen, Johanna

    2017-04-01

    In this study we show the vertical distribution of atmospheric methane (CH4) measured in Sodankylä, Northern Finland. The CH4 profiles are retrieved from the direct Sun FTS measurements using the dimension reduction retrieval method. In the retrieval method, we have a few degrees of freedom about the profile shape. The data set covers years 2010-2016 (from February to November) and altitudes 0-40 km. The retrieved FTS profiles are validated against ACE satellite measurements and AirCore balloon measurements. The total columns derived from the FTS profiles are compared to the official TCCON XCH4 data. A vertically resolved methane data set can be used, e.g., to study stratospheric methane during the polar vortex.

  19. INTERNATIONAL SPECIALIZATION AND VERTICAL DIFFERENTIATION

    Directory of Open Access Journals (Sweden)

    Furia Donatella

    2010-07-01

    Full Text Available During the last decades, market segmentation and intra-industry trade have become increasingly relevant. The underlying hypothesis of our work is that distinct articles have heterogeneous potential for vertical differentiation, implying that different patterns of international specialization should be identifiable. We carry out an analysis on revealed comparative advantage (through the Lafay Index in specific sectors of interest. Then we highlight the emergence of diverse degrees of product quality differentiation among sectors (through the Relative Quality Index. Results confirm our hypothesis. Indeed it appears that only certain goods, for which the pace of either creative or technological innovation (or both is particularly fast, present a high degree of vertical differentiation and market segmentation. This allows countries to specialize in a particular product variety and gain market power position for that variety. These findings should be taken in due consideration when designing trade policies.

  20. Poligonación Vertical

    Directory of Open Access Journals (Sweden)

    Esteban Dörries

    2016-03-01

    Full Text Available La poligonación vertical es un método de medición de diferencias de altura que aprovecha las posibilidades de las estaciones totales. Se presta fundamentalmente para líneas de nivelación entre nodos formando red. El nombre se debe a que las visuales sucesivas se proyectan sobre aristas verticales en lugar de un plano horizontal, como ocurre en la poligonación convencional.

  1. Vertical Launch System Loadout Planner

    Science.gov (United States)

    2015-03-01

    United States Navy USS United States’ Ship VBA Visual Basic for Applications VLP VLS Loadout Planner VLS Vertical Launch System...mathematically complex and require training to operate the software. A Visual Basic for Applications ( VBA ) Excel (Microsoft Corporation, 2015...lockheed/data/ms2/documents/laun chers/MK41 VLS factsheet.pdf Microsoft Excel version 14.4.3, VBA computer software. (2011). Redmond, WA: Microsoft

  2. Trade Liberalisation and Vertical Integration

    DEFF Research Database (Denmark)

    Bache, Peter Arendorf; Laugesen, Anders

    We build a three-country model of international trade in final goods and intermediate inputs and study the relation between different types of trade liberalisation and vertical integration. Firms are heterogeneous with respect to both productivity and factor intensity as observed in data. Final......-economy property rights theory of the firm using firm-level data. Finally, we notice that our model's sorting pattern is in line with recent evidence when the wage difference across countries is not too big....

  3. Prophylaxis of vertical HBV infection.

    Science.gov (United States)

    Pawlowska, Malgorzata; Pniewska, Anna; Pilarczyk, Malgorzata; Kozielewicz, Dorota; Domagalski, Krzysztof

    2016-10-01

    An appropriate management of HBV infection is the best strategy to finally reduce the total burden of HBV infection. Mother-to-child transmission (MTCT) is responsible for more than one third of chronic HBV infections worldwide. Because HBV infection in infancy or early childhood often leads to chronic infection, appropriate prophylaxis and management of HBV in pregnancy is crucial to prevent MTCT. The prevention of HBV vertical transmission is a complex task and includes: universal HBV screening of pregnant women, administration of antivirals in the third trimester of pregnancy in women with high viral load and passive-active HBV immunoprophylaxis with hepatitis B vaccine and hepatitis B immune globulin in newborns of all HBV infected women. Universal screening of pregnant women for HBV infection, early identification of HBV DNA level in HBV-infected mothers, maternal treatment with class B according to FDA antivirals and passive/active anti-HBV immunoprophylaxis to newborns of HBV-positive mothers are crucial strategies for reducing vertical HBV transmission rates. Consideration of caesarean section in order to reduce the risk of vertical HBV transmission should be recommend in HBV infected pregnant women with high viral load despite antiviral therapy or when the therapy in the third trimester of pregnancy is not available.

  4. Bench test and preliminary results of vertical compact torus injection experiments on the STOR-M tokamak

    Science.gov (United States)

    Liu, D.; Xiao, C.; Singh, A. K.; Hirose, A.

    2006-01-01

    The University of Saskatchewan compact torus injector has been modified to allow vertical injection of the compact torus (CT) into the STOR-M tokamak. The injector stayed at the horizontal position and the CT trajectory was bent by 90° using a curved conducting drift tube. The curved drift tube did not significantly slow the CT velocity down or change the CT magnetic field topology. Preliminary vertical CT injection experiments have revealed a prompt increase in the line averaged electron density and in the soft x-ray radiation level in the tokamak discharge immediately following vertical CT injection. Suppression of the m = 2 Mirnov oscillation amplitude has also been observed after CT injection.

  5. Vertical transmission of fungal endophytes is widespread in forbs.

    Science.gov (United States)

    Hodgson, Susan; de Cates, Catherine; Hodgson, Joshua; Morley, Neil J; Sutton, Brian C; Gange, Alan C

    2014-04-01

    To date, it has been thought that endophytic fungi in forbs infect the leaves of their hosts most commonly by air-borne spores (termed "horizontal transmission"). Here, we show that vertical transmission from mother plant to offspring, via seeds, occurs in six forb species (Centaurea cyanus, C. nigra,Papaver rhoeas,Plantago lanceolata,Rumex acetosa, and Senecio vulgaris), suggesting that this may be a widespread phenomenon. Mature seeds were collected from field-grown plants and endophytes isolated from these, and from subsequent cotyledons and true leaves of seedlings, grown in sterile conditions. Most seeds contain one species of fungus, although the identity of the endophyte differs between plant species. Strong evidence for vertical transmission was found for two endophyte species, Alternaria alternata and Cladosporium sphaerospermum. These fungi were recovered from within seeds, cotyledons, and true leaves, although the plant species they were associated with differed. Vertical transmission appears to be an imperfect process, and germination seems to present a bottleneck for fungal growth. We also found that A. alternata and C. sphaerospermum occur on, and within pollen grains, showing that endophyte transmission can be both within and between plant generations. Fungal growth with the pollen tube is likely to be the way in which endophytes enter the developing seed. The fact that true vertical transmission seems common suggests a more mutualistic association between these fungi and their hosts than has previously been thought, and possession of endophytes by seedling plants could have far-reaching ecological consequences. Seedlings may have different growth rates and be better protected against herbivores and pathogens, dependent on the fungi that were present in the mother plant. This would represent a novel case of trans-generational resistance in plants.

  6. Comparison of complication rates, types, and average tube patency between jejunostomy tubes and percutaneous gastrostomy tubes in a regional home enteral nutrition support program.

    Science.gov (United States)

    Ao, Peter; Sebastianski, Meghan; Selvarajah, Vijeyakumar; Gramlich, Leah

    2015-06-01

    Percutaneous endoscopic gastrostomy (PEG) tubes are common enteral access devices for long-term enteral nutrition. Jejunostomy tubes (J-tubes) are able to provide postpyloric enteral access in patients who are not PEG tube candidates. There is a scarcity of literature comparing complication rates of J-tubes to PEG tubes. To compare and characterize J-tube and PEG tube complications requiring tube replacement. A retrospective chart review was performed on 560 patients discharged from the Northern Alberta Home Enteral Nutrition Support Program (NAHENSP) from January 2010 to December 2011. Patients were followed for 3 years from initial tube insertion or until discharge from the NAHENSP, whichever was earliest. Comparisons were made in terms of complications requiring tube replacement, tube patency to first replacement, and indications for tube replacement. A total of 64 J-tube patients were identified and compared with 65 PEG tube patients. Tube replacement rates for the J-tube group included 3.2 cases per 1000 patient days compared with 0.86 cases per 1000 patient days in the PEG group (P < .001). The mean ± SEM duration to first tube replacement for J-tube and PEG tube patients was 160 ± 26.3 days and 331 ± 53.6 days, respectively (P = .010). The most common causes for tube replacement in J-tube patients were dislodgement (35.6%) and obstruction (22.2%) compared with routine replacement (54.5%) and dislodgement (27.2%) in the PEG tube group. J-tubes are associated with higher complication rates requiring tube replacement compared with PEG tubes. The main causes of J-tube replacement are dislodgement and obstruction. © 2014 American Society for Parenteral and Enteral Nutrition.

  7. Thin liquid film in polymer tubing : dynamics and dewetting in partial wetting condition

    Science.gov (United States)

    Hayoun, Pascaline; Letailleur, Alban; Teisseire, Jérémie; Verneuil, Emilie; Lequeux, François; Barthel, Etienne

    2015-11-01

    Polymers such as PVC and Silicone are low cost materials widely used in industry to produce tubing for fluid transport. Most of these applications involve repeated, intermittent flow of liquids which can lead to unwanted contamination. This study aims at better understanding contamination mechanisms during intermittent flow in polymer tubing, and at elucidating the relation between flow, wetting and contamination. We experimentally and theoretically investigate, flow regimes as well as dewetting process at the triple line induced by gravity flow of a vertical liquid slug in a cylindrical geometry. Our results for Newtonian fluids evidence a succession of thick film formation, hydraulic jump creation in the thickness profile, oscillatory regime and destabilization leading to substrate contamination. In order to understand theoretically the flow, one crucial quantity to assess is the film thickness in the inside of the tube. Based on an absorption measurement method, we provide explanations for behaviors and flow regimes observed experimentally.

  8. Multi-tube arrangement for combustor and method of making the multi-tube arrangement

    Energy Technology Data Exchange (ETDEWEB)

    Ziminsky, Willy Steve [Simpsonville, SC

    2012-07-31

    A fuel injector tube includes a one piece, unitary, polygonal tube having an inlet end and an outlet end. The fuel injector tube further includes a fuel passage extending from the inlet end to the outlet end along a longitudinal axis of the polygonal tube, a plurality of air passages extending from the inlet end to the outlet end and surrounding the fuel passage, and a plurality of fuel holes. Each fuel hole connects an air passage with the fuel passage. The inlet end of the polygonal tube is formed into a fuel tube. A fuel injector includes a plurality of fuel injector tubes and a plate. The plurality of fuel tubes are connected to the plate adjacent the inlet ends of the plurality of fuel injector tubes.

  9. [Vertical fractures: apropos of 2 clinical cases].

    Science.gov (United States)

    Félix Mañes Ferrer, J; Micò Muñoz, P; Sánchez Cortés, J L; Paricio Martín, J J; Miñana Laliga, R

    1991-01-01

    The aim of the study is to present a clinical review of the vertical root fractures. Two clinical cases are presented to demonstrates the criteria for obtaining a correct diagnosis of vertical root fractures.

  10. Routine jejunostomy tube feeding following esophagectomy

    Science.gov (United States)

    van Eden, Hanneke W. J.; Ruurda, Jelle P.; Luyer, Misha D. P.; Steenhagen, Elles; Nieuwenhuijzen, Grard A. P.; van Hillegersberg, Richard

    2017-01-01

    Background Malnutrition is an important problem following esophagectomy. A surgically placed jejunostomy secures an enteral feeding route, facilitating discharge with home-tube feeding and long-term nutritional support. However, specific complications occur, and data are lacking that support its use over other enteral feeding routes. Therefore routine jejunostomy tube feeding and discharge with home-tube feeding was evaluated, with emphasis on weight loss, length of stay and re-admissions. Methods Consecutive patients undergoing esophagectomy for cancer, with gastric tube reconstruction and jejunostomy creation, were analyzed. Two different regimens were compared. Before January 07, 2011 patients were discharged when oral intake was sufficient, without tube feeding. After that discharge with home-tube feeding was routinely performed. Logistic regression analysis corrected for confounders. Results Some 236 patients were included. The median duration of tube feeding was 35 days. Reoperation for a jejunostomy-related complication was needed in 2%. The median body mass index (BMI) remained stable during tube feeding. The BMI decreased significantly after stopping tube feeding: from 25.6 (1st–3rd quartile 23.0–28.6) kg/m2 to 24.4 (22.0–27.1) kg/m2 at 30 days later [median weight loss: 3.0 (1.0–5.3) kg; 3.9% (1.5–6.3%)]. Weight loss was not affected by the duration of tube feeding duration. Routine home-tube feeding did not affect weight loss, admission time or the readmission rate. Conclusions Weight loss following esophagectomy occurs once that tube feeding is stopped, independently from the time interval after esophagectomy. Moreover routine discharge with home-tube feeding does not reduce length of stay or readmissions. These findings question the value of routine jejunostomy placement and emphasize the need for further research. PMID:28815083

  11. Development of INCONEL 600 precision tube (1)

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Yeong Han; Jo, Bong Hyeon; Lee, Dong Hee; Kim, Wan Kyo; Jeong, Pyeong Keun; Yoon, Hwang Lo; Chio, Seok Sik [Sammi Steel Co. Ltd., Changwon (Korea, Republic of)

    1994-07-01

    Steam generator, being connected with nuclear fuel reactor is one of the most important part of nuclear power plant and consists of a large number of INCONEL 600 tubes. Approximately 160 tons of tubes are needed for a single nuclear power plant. All of INCONEL 600 steam generator tubes for domestic nuclear power plants have been imported. The aim of this research is to develop INCONEL 600 precision tubes for steam generator of nuclear power plant. If this research is conducted successfully, we can produce nuclear fuel tubes, Ni-alloy precision tubes and stainless steel precision tubes for many purposes and technology of INCONEL 600 steam generator tubes are similar to those of other tubes above mentioned. In the current study, development of preliminary manufacturing process of INCONEL 600 precision tubes for steam generator and investigation of material`s metallurgical characteristics were conducted. The main scope of this research is as follows. First, the preliminary manufacturing process design was conducted after investigations of foreign manufacturing processes and technical reports. Second, the results of investigations of material`s metallurgical characteristics through the manufacturing process were applied to the production technology of tentative INCONEL 600 precision tubes for sample. Third, preliminary process routes were established and samples of INCONEL 600 precision tube were produced by this process. As the results of this research, 14 pieces of INCONEL 600 precision tubes were produced by preliminary manufacturing process and the material`s metallurgical characteristics were investigated through the processes. But the SCC test could not be conducted due to the absence of equipment. In order to apply the results of SCC test to the manufacturing process, we need a SCC tester which can simulate SCC characteristics under high temperature and high pressurized circulating water. 95 refs., 55 figs., 20 tabs.

  12. Cases of fallopian tube prolapse

    Directory of Open Access Journals (Sweden)

    Sushil Chawla

    2015-01-01

    Full Text Available Fallopian tube prolapse post hysterectomy is rarely reported complication which can lead to doubts in the mind of young and experienced surgeons alike. This leads to patient morbidity and gets different medical treatments ranging from antibiotics to local applications of copper sulphate, without relief. The use of proper surgical technique, prevention of post operative hematoma and infection go a long way in its prevention.We hereby present two cases, which were manged successfully to relieve the patients of their agony.

  13. Comparison of primary jejunostomy tubes versus gastrojejunostomy tubes for percutaneous enteral nutrition.

    Science.gov (United States)

    Kim, Charles Y; Engstrom, Bjorn I; Horvath, Jeffrey J; Lungren, Matthew P; Suhocki, Paul V; Smith, Tony P

    2013-12-01

    To evaluate technical success and long-term outcomes of percutaneous primary jejunostomy tubes for postpyloric enteral feeding compared with percutaneous gastrojejunostomy (GJ) tubes. Over a 25-month interval, 41 consecutive patients (26 male; mean age, 55.9 y) underwent attempted fluoroscopy-guided direct percutaneous jejunostomy tube insertion. Insertions at previous jejunostomy tube sites were excluded. The comparison group consisted of all primary GJ tube insertions performed over a 12-month interval concomitant with the jejunostomy tube interval (N = 169; 105 male; mean age, 59.4 y). Procedural, radiologic, and clinical data were retrospectively reviewed. Intervention rates were expressed as events per 100 catheter-days. The technical success rate for percutaneous jejunostomy tube insertion was 96%, versus 93% for GJ tubes (P = .47). Mean fluoroscopy times were similar for jejunostomy and GJ tubes (9.8 vs 10.0 min, respectively; P value not significant). Jejunostomy tubes exhibited a lower rate of catheter dysfunction than GJ tubes, with catheter exchange rates of 0.24 versus 0.93, respectively, per 100 catheter-days (P = .045). GJ tube tip retraction into the stomach occurred in 9.5% of cases, at a rate of 0.21 per 100 catheter-days. Intervention rates related to leakage were 0.19 and 0.03 for jejunostomy and GJ tubes, respectively (P Jejunostomy and GJ tubes exhibited similar rates of catheter exchange for occlusion and replacement as a result of inadvertent removal. No major complications were encountered in either group. Percutaneous insertion of primary jejunostomy tubes demonstrated technical success and complication rates similar to those of GJ tubes. Jejunostomy tubes exhibited a lower dysfunction rate but a higher leakage rate compared with GJ tubes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  14. Determinations of vertical stroke V{sub cb} vertical stroke and vertical stroke V{sub ub} vertical stroke from baryonic Λ{sub b} decays

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao, Y.K. [Shanxi Normal University, School of Physics and Information Engineering, Linfen (China); National Tsing Hua University, Department of Physics, Hsinchu (China); Geng, C.Q. [Shanxi Normal University, School of Physics and Information Engineering, Linfen (China); National Tsing Hua University, Department of Physics, Hsinchu (China); Hunan Normal University, Synergetic Innovation Center for Quantum Effects and Applications (SICQEA), Changsha (China)

    2017-10-15

    We present the first attempt to extract vertical stroke V{sub cb} vertical stroke from the Λ{sub b} → Λ{sub c}{sup +}l anti ν{sub l} decay without relying on vertical stroke V{sub ub} vertical stroke inputs from the B meson decays. Meanwhile, the hadronic Λ{sub b} → Λ{sub c}M{sub (c)} decays with M = (π{sup -},K{sup -}) and M{sub c} =(D{sup -},D{sup -}{sub s}) measured with high precisions are involved in the extraction. Explicitly, we find that vertical stroke V{sub cb} vertical stroke =(44.6 ± 3.2) x 10{sup -3}, agreeing with the value of (42.11 ± 0.74) x 10{sup -3} from the inclusive B → X{sub c}l anti ν{sub l} decays. Furthermore, based on the most recent ratio of vertical stroke V{sub ub} vertical stroke / vertical stroke V{sub cb} vertical stroke from the exclusive modes, we obtain vertical stroke V{sub ub} vertical stroke = (4.3 ± 0.4) x 10{sup -3}, which is close to the value of (4.49 ± 0.24) x 10{sup -3} from the inclusive B → X{sub u}l anti ν{sub l} decays. We conclude that our determinations of vertical stroke V{sub cb} vertical stroke and vertical stroke V{sub ub} vertical stroke favor the corresponding inclusive extractions in the B decays. (orig.)

  15. Bubble motion in sudden expansion in vertical pipe flow

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Koichi [Marine Technical College, Ashiya, Hyogo (Japan); Yoshida, Kenji; Matsumoto, Tadayoshi; Okawa, Tomio; Kataoka, Isao [Osaka Univ., Suita, Osaka (Japan)

    2002-07-01

    Experimental studies were made on the multi-dimensional behavior of upward gas-liquid two-phase flow through the vertical round tube with an axisymmetric sudden expansion, which is one of the typical multi-dimensional channel geometry. The direct observation using high-speed video camera was performed and revealed the multi-dimensional dynamic flow behavior affected by the sudden expansion. Characteristic phenomena were observed such as bubble break-up, deformation due to the strong share of liquid flow, or liquid micro jet penetration through the gas-slug, and so on. From these results, the flow regime map at the below or above of the sudden expansion part was classified. The phase distributions in sudden expansion were also showed in detail that how the two-phase flow develops along the direction of the downstream of the sudden expansion. (J.P.N.)

  16. Narratives From YouTube

    Directory of Open Access Journals (Sweden)

    Mikael Quennerstedt

    2013-10-01

    Full Text Available The aim of this paper is to explore what is performed in students’ and teachers’ actions in physical education practice in terms of “didactic irritations,” through an analysis of YouTube clips from 285 PE lessons from 27 different countries. Didactic irritations are occurrences that Rønholt describes as those demanding “didactic, pedagogical reflections and discussions, which in turn could lead to alternative thinking and understanding about teaching and learning.” Drawing on Barad’s ideas of performativity to challenge our habitual anthropocentric analytical gaze when looking at educational visual data, and using narrative construction, we also aim to give meaning to actions, relations, and experiences of the participants in the YouTube clips. To do this, we present juxtaposing narratives from teachers and students in terms of three “didactic irritations”: (a stories from a track, (b, stories from a game, and (c, stories from a bench. The stories re-present events-of-moving in the data offering insights into embodied experiences in PE practice, making students’ as well as teachers’ actions in PE practice understandable.

  17. Study of heat and mass transfer in evaporative coolers

    Science.gov (United States)

    Perez-Blanco, H.; Bird, W. A.

    1982-06-01

    Evaporative coolers are generally considered efficient and economical devices for rejecting waste heat. In these coolers, a hot fluid circulates inside tubes, rejecting heat to a mixture of air and water. Water is sprayed on the tubes and flows downward while air circulates upward; thus, latent and sensible heat is transferred from the water to the air. Commercially available coolers are of the horizonal tube type; a vertical tube evaporative cooler is studied because it is possible to enhance condensing heat transfer coefficients by using vertical fluted tubes. A mathematical model describing the performance of a single tube is formulated which can predict performance for varied inlet conditions, thereby eliminating the need for extensive testing. The validity of the model rests on the accuracy of the controlling heat and mass transfer coefficients used, so these coefficients are measured experimentally in a single tube cooler and found to agree with existing empirical correlations.

  18. [Enteral feeding tubes for critically ill patients].

    Science.gov (United States)

    Braun, J; Bein, T; Wiese, C H R; Graf, B M; Zausig, Y A

    2011-04-01

    The use of enteral feeding tubes is an important part of early enteral feeding in intensive care medicine. In other faculties with non-critically ill patients, such as (oncologic) surgery, neurology, paediatrics or even in palliative care medicine feeding tubes are used under various circumstances as a temporary or definite solution. The advantage of enteral feeding tubes is the almost physiologic administration of nutrition, liquids and medication. Enteral nutrition is thought to be associated with a reduced infection rate, increased mucosal function, improved immunologic function, reduced length of hospital stay and reduced costs. However, the insertion and use of feeding tubes is potentially dangerous and may be associated with life-threatening complications (bleeding, perforation, peritonitis, etc.). Therefore, the following article will give a summary of the different types of enteral feeding tubes and their range of application. Additionally, a critical look on indication and contraindication is given as well as how to insert an enteral feeding tube.

  19. Why do aged fluorescent tubes flicker?

    Science.gov (United States)

    Plihon, Nicolas; Ferrand, Jérémy; Guyomar, Tristan; Museur, Flavien; Taberlet, Nicolas

    2017-11-01

    Our everyday experience of aged and defective fluorescent tubes or bulbs informs us that they may flicker and emit a clicking sound while struggling to light up. In this article, the physical mechanisms controlling the initial illumination of a functioning fluorescent tube are investigated using a simple and affordable experimental setup. Thermionic emission from the electrodes of the tube controls the startup of fluorescent tubes. The origin of the faulty startup of aged fluorescent tubes is discussed and flickering regimes using functional tubes are artificially produced using a dedicated setup that decreases electron emission by the thermionic effect in a controlled manner. The physical parameters controlling the occurrence of flickering light are discussed, and their temporal statistics are reported.

  20. Dynamic Measurements of Plastic Deformation in a Water-Filled Aluminum Tube in Response to Detonation of a Small Explosives Charge

    OpenAIRE

    Harold Sandusky; Paul Chambers; Frank Zerilli; Larry Fabini; William Gottwald

    1999-01-01

    Experiments have been conducted to benchmark computer code calculations for the dynamic interaction of explosions in water with structures. Aluminum cylinders with a length slightly more than twice their diameter were oriented vertically, sealed on the bottom by a thin plastic sheet, and filled with distilled water. An explosive charge suspended in the center of the tube plastically deformed but did not rupture the wall. Tube wall velocity, displacement, and strain were directly measured. The...

  1. ?Vertical Sextants give Good Sights?

    Science.gov (United States)

    Richey, Michael

    Mark Dixon suggests (Forum, Vol. 50, 137) that nobody thus far has attempted to quantify the errors from tilt that arise while observing with the marine sextant. The issue in fact, with the related problem of what exactly is the axis about which the sextant is rotated whilst being (to define the vertical), was the subject of a lively controversy in the first two volumes of this Journal some fifty years ago. Since the consensus of opinion seems to have been that the maximum error does not necessarily occur at 45 degrees, whereas Dixon's table suggests that it does, some reiteration of the arguments may be in order.

  2. BATCH SETTLING IN VERTICAL SETTLERS

    OpenAIRE

    Lama Ramirez, R.; Universidad Nacional Mayor De San Marcos Facultad de Química e Ingeniería Química Departamento de Operaciones Unitarias Av. Venezuela cdra. 34 sin, Lima - Perú; Condorhuamán Ccorimanya, C.; Universidad Nacional Mayor De San Marcos Facultad de Química e Ingeniería Química Departamento de Operaciones Unitarias Av. Venezuela cdra. 34 sin, Lima - Perú

    2014-01-01

    lt has been studied the batch sedimentation of aqueous suspensions of precipitated calcium carbonate, barium sulphate and lead oxide , in vertical thickeners of rectangular and circular cross sectional area. Suspensions vary in concentration between 19.4 and 617.9 g/I and the rate of sedimentation obtained between 0.008 and 7.70 cm/min. The effect of the specific gravity of the solid on the rate of sedimentation is the same for all the suspensions, that is, the greater the value of the specif...

  3. Binocular responses and vertical strabismus

    Directory of Open Access Journals (Sweden)

    Risović Dušica

    2007-01-01

    Full Text Available Background/Aim. Elevation in adduction is the most common pattern of vertical strabismus, and it is mostly treated with surgery. The results of weaking of inferior oblique muscle are very changeable. The aim of this study was to evaluate binocular vision using sensory tests before and one and six months after the surgery. Methods. A total of 79 children were divided in two groups: the first, with inferior oblique muscle of overaction (n = 52, and the second with dissociated vertical deviation (DVD, and primary inferior oblique muscle overaction (n = 27. We tested them by polaroid mirror test (PMT, Worth test at distance and near, fusion amplitudes on sinoptofore, Lang I stereo test and Wirt-Titmus stereo test. We examined our patients before and two times after the surgery for vertical strabismus. Results. Foveal suppression in the group I was found in 60.5% of the patients before, and in 56.4% after the surgery. In group II Foveal suppression was detected in 64.7% of the patients before, but in 55.6% 6 months after the surgery with PMT. Worth test revealed suppression in 23.5% of the patients before, and in 40.7% after the vertical muscle surgery. Parafoveal fussion persisted in about 1/3 of the patients before the surgery, and their amplitudes were a little larger after the surgery in the group I patients. Lang I stereo test was negative in 53.9% before and 51.9% after the surgery in the group I, and in 48.2% of the patients before and after the surgery in the group II patients. Wirt-Titmus stereo test was negative in 74.5% of the patients before and in 72.9% after the surgery in the group I, but in the group II it was negative in 70.8% before and in 68.0% of the patients 6 months after the surgery. Conclusion. Binocular responses were found after surgery in 65.7% of the patients the group I and in 55.6% patients the group II. There was no significant difference between these two groups, but binocular responses were more often in the patients

  4. DEVELOPMENT OF COILED TUBING STRESS ANALYSIS

    Directory of Open Access Journals (Sweden)

    Davorin Matanović

    1998-12-01

    Full Text Available The use of coiled tubing is increasing rapidly with drilling of horizontal wells. To satisfy all requirements (larger mechanical stresses, larger fluid capacities the production of larger sizes and better material qualities was developed. Stresses due to axial forces and pressures that coiled tubing is subjected are close to its performance limits. So it is really important to know and understand the behaviour of coiled tubing to avoid its break, burst or collapse in the well.

  5. Medication administration through enteral feeding tubes.

    Science.gov (United States)

    Williams, Nancy Toedter

    2008-12-15

    An overview of enteral feeding tubes, drug administration techniques, considerations for dosage form selection, common drug interactions with enteral formulas, and methods to minimize tube occlusion is given. Enteral nutrition through a feeding tube is the preferred method of nutrition support in patients who have a functioning gastrointestinal tract but who are unable to be fed orally. This method of delivering nutrition is also commonly used for administering medications when patients cannot swallow safely. However, several issues must be considered with concurrent administration of oral medications and enteral formulas. Incorrect administration methods may result in clogged feeding tubes, decreased drug efficacy, increased adverse effects, or drug-formula incompatibilities. Various enteral feeding tubes are available and are typically classified by site of insertion and location of the distal tip of the feeding tube. Liquid medications, particularly elixirs and suspensions, are preferred for enteral administration; however, these formulations may be hypertonic or contain large amounts of sorbitol, and these properties increase the potential for adverse effects. Before solid dosage forms are administered through the feeding tube, it should be determined if the medications are suitable for manipulation, such as crushing a tablet or opening a capsule. Medications should not be added directly to the enteral formula, and feeding tubes should be properly flushed with water before and after each medication is administered. To minimize drug-nutrient interactions, special considerations should be taken when administering phenytoin, carbamazepine, warfarin, fluoroquinolones, and proton pump inhibitors via feeding tubes. Precautions should be implemented to prevent tube occlusions, and immediate intervention is required when blockages occur. Successful drug delivery through enteral feeding tubes requires consideration of the tube size and placement as well as careful

  6. Unique removal of a kinked nasogastric tube

    Directory of Open Access Journals (Sweden)

    Kumar Shwetanshu Narayan

    2017-01-01

    Full Text Available Nasogastric (NG tube insertion is a common clinical procedure used for both diagnostic and therapeutic purposes. As the importance of enteral nutrition is being increasingly recognized; the use of NG tube insertion has steadily increased. Here, we present an interesting case in which a kinked NG tube was removed in a unique manner with “push and pull” technique without untoward trauma.

  7. Preparation of nitrogen-doped carbon tubes

    Science.gov (United States)

    Chung, Hoon Taek; Zelenay, Piotr

    2015-12-22

    A method for synthesizing nitrogen-doped carbon tubes involves preparing a solution of cyanamide and a suitable transition metal-containing salt in a solvent, evaporating the solvent to form a solid, and pyrolyzing the solid under an inert atmosphere under conditions suitable for the production of nitrogen-doped carbon tubes from the solid. Pyrolyzing for a shorter period of time followed by rapid cooling resulted in a tubes with a narrower average diameter.

  8. Inverse Kinematics of Concentric Tube Steerable Needles

    OpenAIRE

    Sears, Patrick; Dupont, Pierre E.

    2007-01-01

    Prior papers have introduced steerable needles composed of precurved concentric tubes. The curvature and extent of these needles can be controlled by the relative rotation and translation of the individual tubes. Under certain assumptions on the geometry and design of these needles, the forward kinematics problem can be solved in closed form by means of algebraic equations. The inverse kinematics problem, however, is not as straightforward owing to the nonlinear map between relative tube disp...

  9. Micro tube heat exchangers for Space Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Mezzo fabricates micro tube heat exchangers for a variety of applications, including aerospace, automotive racing, Department of Defense ground vehicles, economizers...

  10. Failure Analysis of a Service Tube

    Science.gov (United States)

    Xie, Zhongdong; Cai, Weiguo; Li, Zhenxing; Guan, YiMing; Zhang, Baocheng; Yang, XiaoTong

    2017-12-01

    One tube was cracked used in the primary reformer furnace in a fertilizer plant for two and half years. In order to find out the causes of cracking, the methods for chemical composition analysis, macro- and microstructure analysis, penetrant testing, weld analysis, crack and surface damage analysis, mechanics property analysis, high temperature endurance performance analysis, stress and wall thickness calculation were adopted. The integrated assessment results showed that the carbon content of the tube was in the lower limit of the standard range; the tube effective wall thickness was too small; local overheating leads to tube cracking in use process.

  11. Enhanced Evaporation and Condensation in Tubes

    Science.gov (United States)

    Honda, Hiroshi

    A state-of-the-art review of enhanced evaporation and condensation in horizontal microfin tubes and micro-channels that are used for air-conditioning and refrigeration applications is presented. The review covers the effects of flow pattern and geometrical parameters of the tubes on the heat transfer performance. Attention is paid to the effect of surface tension which leads to enhanced evaporation and condensation in the microfin tubes and micro-channels. A review of prior efforts to develop empirical correlations of the heat transfer coefficient and theoretical models for evaporation and condensation in the horizontal microfin tubes and micro-channels is also presented.

  12. Vertically stacked nanocellulose tactile sensor.

    Science.gov (United States)

    Jung, Minhyun; Kim, Kyungkwan; Kim, Bumjin; Lee, Kwang-Jae; Kang, Jae-Wook; Jeon, Sanghun

    2017-11-16

    Paper-based electronic devices are attracting considerable attention, because the paper platform has unique attributes such as flexibility and eco-friendliness. Here we report on what is claimed to be the firstly fully integrated vertically-stacked nanocellulose-based tactile sensor, which is capable of simultaneously sensing temperature and pressure. The pressure and temperature sensors are operated using different principles and are stacked vertically, thereby minimizing the interference effect. For the pressure sensor, which utilizes the piezoresistance principle under pressure, the conducting electrode was inkjet printed on the TEMPO-oxidized-nanocellulose patterned with micro-sized pyramids, and the counter electrode was placed on the nanocellulose film. The pressure sensor has a high sensitivity over a wide range (500 Pa-3 kPa) and a high durability of 10(4) loading/unloading cycles. The temperature sensor combines various materials such as poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS), silver nanoparticles (AgNPs) and carbon nanotubes (CNTs) to form a thermocouple on the upper nanocellulose layer. The thermoelectric-based temperature sensors generate a thermoelectric voltage output of 1.7 mV for a temperature difference of 125 K. Our 5 × 5 tactile sensor arrays show a fast response, negligible interference, and durable sensing performance.

  13. Generation of flux tube waves in stellar convection zones. 1: Longitudinal tube waves

    Science.gov (United States)

    Musielak, Z. E.; Rosner, R.; Ulmschneider, P.

    1987-01-01

    The source functions and the energy fluxes are derived for wave generation in magnetic flux tubes embedded in an otherwise magnetic- field free, turbulent, and compressible fluid. Specific results for the generation of longitudinal tube waves are presented.

  14. Two-Phase Pressure Drop of a Refrigerant Flowing Vertically Downward in a Mini-channel

    Science.gov (United States)

    Miyata, Kazushi; Enoki, Koji; Mori, Hideo; Hamamoto, Yoshinori

    Experiments were performed on two-phase pressure drop of a refrigerant R-410A flowing vertically downward in small copper circular tubes with 0.5-2.0 mm I.D., and small copper rectangular and triangular tubes with 1.04 and 0.88 mm inner hydraulic equivalent diameter, respectively, for the development of a high-performance heat exchanger using small tubes or multi-port extruded tubes for air conditioning systems.Pressure drops were measured and flow patterns were observed in the range of mass flux from 30 to 400 kg/(m2s)and quality from 0.1 to 0.9 at the saturation temperature of 10 °C. Characteristics of measured pressure drops were examined for different flow channel geometries. In high quality region or relatively high mass flux condition, the frictional pressure drop was reproduced well by the Lockhart-Martinelli correlation used together with a new correlation for Chisholm's parameter C as a function of hydraulic equivalent diameter. In low mass flux and low quality region, the frictional pressure drop was also reproduced well by multiplying the Chisholm two-phase multiplier factor by modified coefficient. In addition, flow pattern was observed with 0.5 and 2.0 mm I.D circular glass tubes. Slug flow and annular flow patterns were observed at lower and higher quality, respectively.

  15. Sunspots and the physics of magnetic flux tubes. V - Mutual hydrodynamic forces between neighboring tubes

    Science.gov (United States)

    Parker, E. N.

    1979-01-01

    The mutual hydrodynamic forces between parallel cylinders in a moving fluid are illustrated through several formal examples. Parallel tubes in a uniform flow are attracted or repelled depending on whether they are side by side or one ahead of the other, respectively. A pulsating or undulating tube attracts all other neighboring tubes toward itself. These hydrodynamic effects suggest that the separate flux tubes beneath the sunspots exert significant attractive forces on each other.

  16. Heat transfer and visualization of falling film evaporation on a tube bundle

    Energy Technology Data Exchange (ETDEWEB)

    Christians, M.

    2010-07-01

    Horizontal falling film evaporators have the potential of displacing flooded evaporators in industry, due to advantages such as lower required refrigerant charge and lower pressure drop. However, there is a need to improve the understanding of falling film evaporation mechanisms to provide accurate thermal design methods. In this work, the existing LTCM falling film facility was utilized to perform falling film evaporation measurements on a single tube, a vertical row of horizontal tubes and a small tube bundle. Two enhanced boiling tubes, namely the Wolverine Turbo-B5 and the Wieland Gewa-B5, were tested using R-134a and R-236fa. The tests were carried out at a constant saturation temperature of T{sub sat} = 5 °C, liquid film Reynolds numbers ranging from 0 to 3000, and heat fluxes between 15 and 90 kW/m{sup 2} in pool boiling and falling film configurations. A visualization study was performed under adiabatic and diabatic conditions (in both single-array and bundle configurations) to study the flow. The physical phenomena governing the falling film evaporation process have been studied, and insight into their effects on the performance of tube bundles has been gained. Measurements of the local heat transfer coefficient were obtained and utilized to generate new prediction methods, including a method for predicting the onset-of-dryout film flow rate during falling film evaporation, local pool boiling and falling film heat transfer prediction methods and a falling film multiplier prediction method. (author)

  17. Study and modelling of a reactional tube bundle heated by a fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Collantes Hernandez, M.A.

    1993-07-01

    Fluidized beds exhibit two important characteristics for the heating of a reactional tube bundle: homogeneous temperature within all the fluidized bed and high heat transfer coefficient with the immersed surfaces. One of the key points for their modeling is the knowledge of the vertical and horizontal thermal conductivities and the heat transfer coefficient at the wall or with the tubes of the reactor. As thermal diffusivity data about large fluidized beds are not available in the literature, we have built a large size pilot unit (0.6 m x 1.1 m x 2.8 m) to determine these values under the conditions of a catalytic treatment of petroleum products. The measure of local temperatures and the use of a two-dimensional diffusion model have permitted us to determine thermal conductivities as a function of several parameters: fluidization velocity, height of the bed, nature and granulometry of solids and geometry of the tube bundle. On the basis of the collected experimental data, the case of a petrochemical unit has been studied. A mathematical code was developed, which permitted us to acquire the data concerning the progress of the reaction in the tubes and it also allowed us to analyse the influence of size and density of the tube bundles on the conversion. (author). 72 refs., 90 figs., 15 tabs.

  18. Working session 2: Tubing inspection

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, J. [Tecnatom, S.A. San Sebastian de los Reyes, Madrid (Spain); Tapping, R.L. [AECL, Chalk River, Ontario (Canada)

    1997-02-01

    This session was attended by delegates from 10 countries, and four papers were presented. A wide range of issues was tabled for discussion. Realizing that there was limited time available for more detailed discussion, three topics were chosen for the more detailed discussion: circumferential cracking, performance demonstration (to focus on POD and sizing), and limits of methods. Two other subsessions were organized: one dealt with some challenges related to the robustness of current inspection methods, especially with respect to leaving cracked tubes in service, and the other with developing a chart of current NDE technology with recommendations for future development. These three areas are summarized in turn, along with conclusions and/or recommendations. During the discussions there were four presentations. There were two (Canada, Japan) on eddy current probe developments, both of which addressed multiarray probes that would detect a range of flaws, one (Spain) on circumferential crack detection, and one (JRC, Petten) on the recent PISC III results.

  19. Paramecium swimming in capillary tube

    CERN Document Server

    Jana, Saikat; Jung, Sunghwan

    2010-01-01

    Swimming organisms in their natural habitat navigate through a wide array of geometries and chemical environments. Interaction with the boundaries is ubiquitous and can significantly modify the swimming characteristics of the organism as observed under ideal conditions. We study the dynamics of ciliary locomotion in Paramecium multimicronucleatum and observe the effect of the solid boundaries on the velocities in the near field of the organism. Experimental observations show that Paramecium executes helical trajectories that slowly transition to straight line motion as the diameter of the capillary tubes decrease. Theoretically this system is modeled as an undulating cylinder with pressure gradient and compared with experiments; showing that such considerations are necessary for modeling finite sized organisms in the restrictive geometries.

  20. Failure analysis of retired steam generator tubings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Pyo; Kim, J. S.; Hwang, S. S. and others

    2005-04-15

    Degradation of steam generator leads to forced outage and extension of outage, which causes increase in repair cost, cost of purchasing replacement power and radiation exposure of workers. Steam generator tube rupture incident occurred in Uljin 4 in 2002, which made public sensitive to nuclear power plant. To keep nuclear energy as a main energy source, integrity of steam generator should be demonstrated. Quantitative relationship between ECT(eddy current test) signal and crack size is needed in assesment of integrity of steam generator in pressurized water reactor. However, it is not fully established for application in industry. Retired steam generator of Kori 1 has many kinds of crack such as circumferential and axial primary water stress corrosion crack and outer diameter stress corrosion crack(ODSCC). So, it can be used in qualifying and improving ECT technology and in condition monitoring assesment for crack detected in ISI(in service inspection). In addition, examination of pulled tube of Kori 1 retired steam generator will give information about effectiveness of non welded sleeving technology which was employed to repair defect tubes and remedial action which was applied to mitigate ODSCC. In this project, hardware such as semi hot lab. for pulled tube examination and modification transportation cask for pulled tube and software such as procedure of transportation of radioactive steam generator tube and non-destructive and destructive examination of pulled tube were established. Non-destructive and destructive examination of pulled tubes from Kori 1 retired steam generator were performed in semi hot lab. Remedial actions applied to Kori 1 retired steam generator, PWSCC trend and bulk water chemistry and crevice chemistry in Kori 1 were evaluated. Electrochemical decontamination technology for pulled tube was developed to reduce radiation exposure and enhance effectiveness of pulled tube examination. Multiparameter algorithm developed at ANL, USA was

  1. Observation of "YouTube" Language Learning Videos ("YouTube" LLVS)

    Science.gov (United States)

    Alhamami, Munassir

    2013-01-01

    This paper navigates into the "YouTube" website as one of the most usable online tools to learn languages these days. The paper focuses on two issues in creating "YouTube" language learning videos: pedagogy and technology. After observing the existing "YouTube" LLVs, the study presents a novel rubric that is directed…

  2. 49 CFR 230.61 - Arch tubes, water bar tubes, circulators and thermic siphons.

    Science.gov (United States)

    2010-10-01

    ... (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Washing Boilers § 230.61 Arch tubes, water bar tubes, circulators and thermic siphons. (a) Frequency of cleaning. Each time the boiler is washed, arch tubes and...

  3. Optimization of blade motion of vertical axis turbine

    Science.gov (United States)

    Ma, Yong; Zhang, Liang; Zhang, Zhi-yang; Han, Duan-feng

    2016-04-01

    In this paper, a method is proposed to improve the energy efficiency of the vertical axis turbine. First of all, a single disk multiple stream-tube model is used to calculate individual fitness. Genetic algorithm is adopted to optimize blade pitch motion of vertical axis turbine with the maximum energy efficiency being selected as the optimization objective. Then, a particular data processing method is proposed, fitting the result data into a cosine-like curve. After that, a general formula calculating the blade motion is developed. Finally, CFD simulation is used to validate the blade pitch motion formula. The results show that the turbine's energy efficiency becomes higher after the optimization of blade pitch motion; compared with the fixed pitch turbine, the efficiency of variable-pitch turbine is significantly improved by the active blade pitch control; the energy efficiency declines gradually with the growth of speed ratio; besides, compactness has lager effect on the blade motion while the number of blades has little effect on it.

  4. Efficiency Analysis of the Main Components of a Vertical Closed-Loop System in a Borehole Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Cristina Sáez Blázquez

    2017-02-01

    Full Text Available In vertical closed-loop systems, it is common to use single or double U-tube heat exchangers separated by longitudinal spacers. In addition, the helical-shaped pipe is another configuration that requires lower drilling lengths but it is less used. The aim of the present research is to study the influence of these components on the total efficiency of a borehole heat exchanger (BHE. Thus, the differences between using single/double U-tubes (with or without spacers and helical pipes are analysed in terms of efficiency. Through different laboratory tests, a small vertical closed-loop system was simulated in order to analyse all these possible configurations. The grouting materials and the temperatures of the ground were modified at the same time in these tests. Regarding the heat exchange process between the ground and the heat carrier fluid, it must be highlighted that the best results were obtained for the helical-shaped pipe configuration. Some of the improvements offered by this heat exchanger typology with respect to the vertical configuration is that a lower drilling depth is required even it requires a larger diameter. This leads to significant economic savings in the performing drilling process. Finally, it is also worth noting the importance of using spacers in vertical U-tubes and that no improvements have been found regarding the use of single or double configuration of U-tubes. Thanks to the laboratory results derived from this study it is possible to establish the optimum behaviour pattern for the entire vertical closed-loop systems.

  5. Broadcast yourself on YouTube - really?

    NARCIS (Netherlands)

    Kruitbosch, G.; Nack, F.

    2008-01-01

    One essential reason for people to publish on the web is to express themselves freely. YouTube facilitates this self-expression by allowing users to upload video content they generated. This paper investigates to what extent the videos on YouTube are self-generated content, instead of amalgamated

  6. Short Communication Tube-forming polychaetes enhance ...

    African Journals Online (AJOL)

    We collected invertebrate samples from an intertidal flat with low onuphid tube density (2.7 m–2) in Mozambique and document that more organisms (70 times higher mollusc abundances) and more species (15 times more mollusc species) were found associated with solitary tubes of an onuphid polychaete compared with ...

  7. Selecting silicone tubing for device applications.

    Science.gov (United States)

    Jahn, D

    2005-10-01

    A number of factors are involved in selecting the most suitable silicone tubing for a given purpose. These include physical chemistry, performance properties, a supplier's quality system and regulatory compliance. This article provides a guide for device developers when selecting silicone tubing for their applications.

  8. Non-uniform tube representation of proteins

    DEFF Research Database (Denmark)

    Hansen, Mikael Sonne

    might not correctly capture volume exclusion - of crucial importance when trying to understand a proteins $3$d-structure. We propose a new reduced model treating the protein as a non-uniform tube with a radius reflecting the positions of atoms. The tube representation is well suited considering X...

  9. Non-Uniform Tube Representation of Proteins

    DEFF Research Database (Denmark)

    Hansen, Mikael Sonne

    might not correctly capture volume exclusion - of crucial importance when trying to understand a protein's 3d-structure. We propose a new reduced model treating the protein as a non-uniform tube with a radius reflecting the positions of atoms. The tube representation is well suited considering X...

  10. Places to Go: YouTube

    Science.gov (United States)

    Downes, Stephen

    2008-01-01

    Founded in 2005 by three former PayPal employees, YouTube has revolutionized the Internet, marking a change from the static Internet to the dynamic Internet. In this edition of Places to Go, Stephen Downes discusses how the rise of a ubiquitous media format--Flash video--has made YouTube's success possible and argues that Flash video has important…

  11. Photomultiplier tubes for Low Level Cerenkov Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Strindehag, O.

    1965-03-15

    Tube backgrounds of several 2-inch photomultiplier types having S11, 'S' , S13 and S20 cathodes are compared by measuring signal and background pulse height distributions at pulse heights corresponding to a few photo-electrons. The reference signal is generated by means of a {beta}-source and a plexiglass radiator. It is found that comparatively good results are obtained with selected tubes of the EMI types 6097B and 9514B having equivalent dark current dc values down to 10{sup -12} input lumens. Special interest is devoted to the correlation between the measured tube backgrounds and the dark current dc values of the tubes, as a good correlation between these parameters simplifies the selection of photomultiplier tubes. The equivalent dark currents of the tested tubes extend over the range 10{sup -12} to 10{sup -9} input lumens. Although the investigation deals with photomultiplier tubes intended for use in low level Cerenkov detectors it is believed that the results could be valuable in other fields where photomultiplier tubes are utilized for the detection of weak light pulses.

  12. Confined Tube Crimp Using Portable Hand Tools

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, Joseph James [Los Alamos National Laboratory; Pereyra, R. A. [LANL Retired; Archuleta, Jeffrey Christopher [Los Alamos National Laboratory; Martinez, Isaac P. [Los Alamos National Laboratory; Nelson, A. M. [MST-16 Summer Student (2007); Allen, Ronald Scott [Los Alamos National Laboratory; Page, R. L. [LANL Retired; Freer, Jerry Eugene [Los Alamos National Laboratory; Dozhier, Nathan Gus [Los Alamos National Laboratory

    2016-04-04

    The Lawrence Radiation Laboratory developed handheld tools that crimp a 1/16 inch OD tube, forming a leak tight seal1 (see Figure 1). The leak tight seal forms by confining the 1/16 inch OD tubing inside a die while applying crimp pressure. Under confined pressure, the tube walls weld at the crimp. The purpose of this study was to determine conditions for fabricating a leak tight tube weld. The equipment was used on a trial-and-error basis, changing the conditions after each attempt until successful welds were fabricated. To better confine the tube, the die faces were polished. Polishing removed a few thousandths of an inch from the die face, resulting in a tighter grip on the tubing wall. Using detergent in an ultrasonic bath, the tubing was cleaned. Also, the time under crimp pressure was increased to 30 seconds. With these modifications, acceptable cold welds were fabricated. After setting the conditions for an acceptable cold weld, the tube was TIG welded across the crimped face.

  13. Sampling Artifacts from Conductive Silicone Tubing

    Energy Technology Data Exchange (ETDEWEB)

    Timko, Michael T.; Yu, Zhenhong; Kroll, Jesse; Jayne, John T.; Worsnop, Douglas R.; Miake-Lye, Richard C.; Onasch, Timothy B.; Liscinsky, David; Kirchstetter, Thomas W.; Destaillats, Hugo; Holder, Amara L.; Smith, Jared D.; Wilson, Kevin R.

    2009-05-15

    We report evidence that carbon impregnated conductive silicone tubing used in aerosol sampling systems can introduce two types of experimental artifacts: 1) silicon tubing dynamically absorbs carbon dioxide gas, requiring greater than 5 minutes to reach equilibrium and 2) silicone tubing emits organic contaminants containing siloxane that adsorb onto particles traveling through it and onto downstream quartz fiber filters. The consequence can be substantial for engine exhaust measurements as both artifacts directly impact calculations of particulate mass-based emission indices. The emission of contaminants from the silicone tubing can result in overestimation of organic particle mass concentrations based on real-time aerosol mass spectrometry and the off-line thermal analysis of quartz filters. The adsorption of siloxane contaminants can affect the surface properties of aerosol particles; we observed a marked reduction in the water-affinity of soot particles passed through conductive silicone tubing. These combined observations suggest that the silicone tubing artifacts may have wide consequence for the aerosol community and should, therefore, be used with caution. Gentle heating, physical and chemical properties of the particle carriers, exposure to solvents, and tubing age may influence siloxane uptake. The amount of contamination is expected to increase as the tubing surface area increases and as the particle surface area increases. The effect is observed at ambient temperature and enhanced by mild heating (<100 oC). Further evaluation is warranted.

  14. Isolated Fallopian Tube Torsion in Adolescents

    Directory of Open Access Journals (Sweden)

    S. Rajaram

    2013-01-01

    Full Text Available Background. Fallopian tube torsion is a rare cause of acute abdomen, occurring commonly in females of reproductive age. It lacks pathognomonic symptoms, signs, or imaging features, thus causing delay in surgical intervention. Case. We report two cases of isolated fallopian tube torsion in adolescent girls. In the first case a 19-year-old patient presented with acute pain in the left iliac region associated with episodes of vomiting for one day and mild tenderness on examination. Laparoscopy revealed left sided twisted fallopian tube associated with hemorrhagic cyst of ovary. The tube was untwisted and salvaged. In another case an 18-year-old virgin girl presented with similar complaints since one week, associated with mild tenderness in the lower abdomen and tender cystic mass on per rectal examination. On laparoscopy right twisted fallopian tube associated with a paratubal cyst was found. Salpingectomy was done as the tube was gangrenous. Conclusion. Fallopian tube torsion, though rare, should be considered in women of reproductive age with unilateral pelvic pain. Early diagnostic laparoscopy is important for an accurate diagnosis and could salvage the tube.

  15. A Slot Machine, A Broken Test Tube

    Indian Academy of Sciences (India)

    IAS Admin

    BOOK │ REVIEW. A Slot Machine, A Broken. Test Tube. Vinita Shivakumar and. Dipshikha Chakravortty. A Slot Machine, A Broken Test. Tube – An Autobiography. Salvador Edward Luria. Harper Collins Publishers Inc.,. USA. 1984. 1st edn. 228 pp. (Original from the University of. Michigan). Price: Rs 60/-. Salvador Edward ...

  16. Teaching Shakespeare with YouTube

    Science.gov (United States)

    Desmet, Christy

    2009-01-01

    YouTube, the video sharing website that allows viewers to upload video content ranging from cute dog tricks to rare rock videos, also supports a lively community devoted to the performance of Shakespeare and Shakespearean adaptations. YouTube is also a popular site for student producers of Shakespeare performances, parodies, and other artistic…

  17. Geotextile Tube Structures Guidelines for Contract Specifications

    Science.gov (United States)

    2006-09-01

    Nonwoven fabrics: Diaphragm Bursting Strength Tester Method ASTM D 3884 (1992) Abrasion Resistance of Textile Fabrics (Rotary Platform, Double-Head... filter cloth, excavation of borrow material, transportation of borrow material, filling of the tubes, coating of the completed tubes, disposal of waste

  18. Capillary holdup between vertical spheres

    Directory of Open Access Journals (Sweden)

    S. Zeinali Heris

    2009-12-01

    Full Text Available The maximum volume of liquid bridge left between two vertically mounted spherical particles has been theoretically determined and experimentally measured. As the gravitational effect has not been neglected in the theoretical model, the liquid interface profile is nonsymmetrical around the X-axis. Symmetry in the interface profile only occurs when either the particle size ratio or the gravitational force becomes zero. In this paper, some equations are derived as a function of the spheres' sizes, gap width, liquid density, surface tension and body force (gravity/centrifugal to estimate the maximum amount of liquid that can be held between the two solid spheres. Then a comparison is made between the result based on these equations and several experimental results.

  19. On the Generation of Flux-Tube Waves in Stellar Convection Zones. III. Longitudinal Tube Wave-Energy Spectra and Fluxes for Late-Type Stars

    Science.gov (United States)

    Musielak, Z. E.; Rosner, R.; Ulmschneider, P.

    2000-09-01

    The wave-energy spectra and fluxes for longitudinal tube waves generated in stellar convection zones are computed by using analytical methods developed in the two previous papers of this series. The main physical process responsible for the generation of these waves is the interaction between a thin and vertically oriented magnetic flux tube and the external turbulent convection. The spatial component of the turbulent convection is represented by an extended Kolmogorov turbulent energy spectrum, and its temporal component by a modified Gaussian frequency factor. The calculations are performed for Population I stars with effective temperatures ranging from Teff=2000 K to 10,000 K, and with gravities logg=3-5. The obtained results can be used to construct theoretical models of magnetic regions in stellar chromospheres.

  20. Local Thickening of Stainless Tube Considering Dimension Variation of the Cold Roll Formed Tube Billet

    Science.gov (United States)

    Sheu, Jinn-Jong; Yu, Cheng-Hsien

    2011-01-01

    A stud end consists of tube body and a flange in order to connect two tubes to form a long straight or angled pipe line. The flange is thicker than the tube body to strengthen the pipe connection. A thicker round hollow disk is usually welded to a straight tube to get the flange of the tube end and then machined to the specified dimension of the two-piece type stud end. A one-piece type stud end of tube proposed here is produced via the local thickening of tube end, flaring, and flange forging processes. The roundness of raw tube is not promised in the cold roll forming (CRF) process, which causes the inaccuracy of dimensions, wrinkling, and folding defects during the local thickening process of tube end. In this paper, a preform process was proposed to correct the dimension of the tube to be thickened. The CRF tube billets were measured and preformed to the required dimensions before thickening. The proposed preforming process was able to resize and control the dimensions and roundness of the tube billet to prevent irregular movement of billet. A three-staged punch profile was designed to prevent the folding defect during the thickening process. Experiments of resizing and thickening were carried out to verify the simulation results and the proposed punch profile design. The CAE simulations demonstrated the defects of folding are very sensitive to the dimension variation of tube billet. The experimental results of thickening process were in good agreement with the simulation predictions using the perfect (with preforming process) and the imperfect (original CRF) tube billets. The proposed pre-forming process and the punch profile designs were able to minimize the surface defects of tube local thickening.

  1. Building lab-scale x-ray tube based irradiators

    Science.gov (United States)

    The construction of economical x-ray tube based irradiators in a variety of configurations is described using 1000 Watt x-ray tubes. Single tube, double tube, and four tube designs are described, as well as various cabinet construction techniques. Relatively high dose rates were achieved for small s...

  2. Vertical jump coordination: fatigue effects.

    Science.gov (United States)

    Rodacki, André Luiz Felix; Fowler, Neil E; Bennett, Simon J

    2002-01-01

    The aim of this study was to investigate the segmental coordination of vertical jumps under fatigue of the knee extensor and flexor muscles. Eleven healthy and active subjects performed maximal vertical jumps with and without fatigue, which was imposed by requesting the subjects to extend/flex their knees continuously in a weight machine, until they could not lift a load corresponding to approximately 50% of their body weight. Knee extensor and flexor isokinetic peak torques were also measured before and after fatigue. Video, ground reaction forces, and electromyographic data were collected simultaneously and used to provide several variables of the jumps. Fatiguing the knee flexor muscles did not reduce the height of the jumps or induce changes in the kinematic, kinetic, and electromyographic profiles. Knee extensor fatigue caused the subjects to adjust several variables of the movement, in which the peak joint angular velocity, peak joint net moment, and power around the knee were reduced and occurred earlier in comparison with the nonfatigued jumps. The electromyographic data analyses indicated that the countermovement jumps were performed similarly, i.e., a single strategy was used, irrespective of which muscle group (extensor or flexors) or the changes imposed on the muscle force-generating characteristics (fatigue or nonfatigue). The subjects executed the movements as if they scaled a robust template motor program, which guided the movement execution in all jump conditions. It was speculated that training programs designed to improve jump height performance should avoid severe fatigue levels, which may cause the subjects to learn and adopt a nonoptimal and nonspecific coordination solution. It was suggested that the neural input used in the fatigued condition did not constitute an optimal solution and may have played a role in decreasing maximal jump height achievement.

  3. Tubing-for-casing cuts tubular requirements

    Energy Technology Data Exchange (ETDEWEB)

    Kelley, C.W. Jr.

    1974-04-01

    The tight supply of tubular goods has caused many operators to turn to tubingless completions in field wells devoid of critical downhole problems. It is possible to save up to 50% on tubular steel requirements by this technique. Other than the surface casing, the basic idea employs only one string of pipe of tubing dimensions. Such a completion is illustrated. Tubingless completions generally refer to the use of 2-7/8 in. tubing which is run and cemented as the production casing of a well. In this light, the term tubingless is a misnomer and perhaps tubing-for-casing more aptly described the idea. Tubing-for-casing completions should be considered usually for gas wells where future anticipated remedial work is minimal. However, these completions can be squeezed and normal remedial work can be accomplished with a variety of available tools. Some of the problems that should be investigated when considering a tubing-for-casing are listed and described.

  4. The Mashups of YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2013-01-01

    This article focuses on YouTube mashups and how we can understand them as a specific subgenre on YouTube. The Mashups are analysed as audiovisual recontextualizations that are given new meaning, e.g., via collaborative social communities or for individual promotional purposes. This is elaborated......, but rather in its social and communicative abilities within the YouTube community. This leads to the article’s overall argument that the main characteristic of the YouTube Mashup can be explained in terms of connectivity. It is argued that Mashups reveal a double articulation of connectivity; one...... that involves the social mechanisms of the Mashups, and another mode, which concerns the explicit embedding of structural connectivity that accentuates the medium-specific infrastructure of YouTube. This double articulation of connectivity is furthermore elaborated on by including Grusin and Bolter’s concept...

  5. Torsional Kinematic Model for Concentric Tube Robots.

    Science.gov (United States)

    Dupont, Pierre E; Lock, Jesse; Butler, Evan

    2009-05-12

    A recent approach to steerable needle design is based on combining pre-curved tubes concentrically. By rotating and extending the tubes with respect to each other, the position and orientation of the needle tip, as well as the shape of the inserted length, can be controlled. Prior models neglected torsional twisting in the curved portions of the tubes. This paper presents a mechanics model that includes torsion, applies to any number of tubes and allows curvature and stiffness to vary with arc length. While the general model is comprised of differential equations, an analytic solution is given for two tubes of constant curvature. This solution enables analytic prediction of "snap through" instability based on a single dimensionless parameter. Simulation and experiments are used to illustrate the results.

  6. Can nasal decongestants improve eustachian tube function?

    Science.gov (United States)

    Ovari, Attila; Buhr, Anne; Warkentin, Mareike; Kundt, Günther; Ehrt, Karsten; Pau, Hans-Wilhelm

    2015-01-01

    To evaluate the effect of nasal decongestants on eustachian tube (ET) opening. A prospective nonrandomized study. A tertiary referral center. Twenty-four patients (44 ears) with intact eardrums, 39 patients (43 ears) having a noninfected eardrum defect, and six patients with an upper airway infection. Nasal or intratympanal (in perforated ears) application of a nasal decongestant (xylometazoline 0.1%). Change of tube opening quality (yes or no; better or worse) measuring tube opening parameters (pressure, latency) using the Estève method and pressure equalization tests (swallowing at negative and positive external ear canal pressures). In most cases, nasal decongestion or intratympanal use of decongestants have no effect on ET opening. Improvement in tube opening is rather an exception and, in a minority of patients, a reduced ET function was evident. Our acute studies revealed no improvement in eustachian ventilatory tube function with the administration of nasal decongestants.

  7. Robotized Inspection of Vertical Structures of a Solar Power Plant Using NDT Techniques

    Directory of Open Access Journals (Sweden)

    Torsten Felsch

    2015-03-01

    Full Text Available Concentrated solar power (CSP plants are expansive facilities that require substantial inspection and maintenance. A fully automated inspection robot increases the efficiency of maintenance work, reduces operating and maintenance costs, and improves safety and work conditions for service technicians. This paper describes a climbing robot that is capable of performing inspection and maintenance on vertical surfaces of solar power plants, e.g., the tubes of the receiver in a central tower CSP plant. Specifically, the service robot’s climbing mechanism is explained and the results of the nondestructive inspection methods are reviewed. The robot moves on the panels of the receiver in the tower and aligns the sensors correctly for inspection. The vertical movement of the climbing kinematics is synchronized with the movement of the tower’s crane. Various devices that detect surface defects and thickness losses inside the tube were integrated into the robot. Since the tubes are exposed to very high radiation, they need to be inspected regularly.

  8. Tratamento da obesidade mórbida com gastrectomia vertical Treatment of morbid obesity with vertical gastrectomy

    Directory of Open Access Journals (Sweden)

    Alcides José Branco-Filho

    2011-03-01

    Full Text Available RACIONAL: A gastrectomia vertical constitui-se em uma das opções de tratamento para a obesidade mórbida. Com a remoção de parte relevante da grande curvatura gástrica, cria-se um estômago tubular com pequena capacidade volumétrica, dando a característica restritiva à operação. OBJETIVOS: Avaliar os pacientes submetidos à gastrectomia vertical quanto ao gênero, idade, índice de massa corporal, co-morbidades associadas, tempo de internamento e evolução pósoperatória a curto prazo. MÉTODOS: Realizou-se um estudo descritivo e retrospectivo em que foram analisados os prontuários de 114 pacientes obesos mórbidos submetidos à gastrectomia vertical. RESULTADOS: Dos 114 pacientes, 107 (93,8% eram do gênero masculino, sendo que a idade média foi de 38 anos (19 a 55. O índice de massa corporal médio foi de 45,9 kg/m² (35 a 65. O tempo de internamento teve um mínimo de 3 e máximo de 48 dias. A principal co-morbidade associada foi a hipertensão arterial sistêmica (63%. Como evolução pós-operatória, 24 pacientes (21% necessitaram de cuidados em unidade de terapia intensiva e houve um total de quatro óbitos (3,5%. CONCLUSÕES: A gastrectomia vertical constitui-se em método seguro e eficaz para perda de peso em obesos mórbidos, sendo uma técnica cirúrgica com baixa morbimortalidade e bons resultados cirúrgicos imediatos.BACKGROUND: Vertical gastrectomy is an option to morbid obesity treatment.Removing a relevant part of the stomach's great curvature, a gastric tube is created with low volumetric capacity, giving to the operation the restrictive characteristic. AIM: To evaluate the patients submitted to vertical gastrectomy regarding gender, age, body mass index, associated comorbidities, time of hospitalization and evolution on the early postoperative period. METHODS: This was a descriptive and retrospective study that analyzed the medical records of 114 morbidly obese patients submitted to vertical gastrectomy. RESULTS

  9. Atmosphere in a Test Tube

    Science.gov (United States)

    Claudi, R.; Pace, E.; Ciaravella, A.; Micela, G.; Piccioni, G.; Billi, D.; Cestelli Guidi, M.; Coccola, L.; Erculiani, M. S.; Fedel, M.; Galletta, G.; Giro, E.; La Rocca, N.; Morosinotto, T.; Poletto, L.; Schierano, D.; Stefani, S.

    The ancestor philosophers' dream of thousand of new world is finally realised: more than 1800 extrasolar planets have been discovered in the neighborhood of our Sun. Most of them are very different from those we used to know in our Solar System. Others orbit the Habitable Zone (HZ) of their parent stars. Space missions, as JWST and the very recently proposed ARIEL, or ground based instruments, like SPHERE@VLT, GPI@GEMINI and EPICS@ELT, have been proposed and built to measure the atmospheric transmission, reflection and emission spectra over a wide wavelength range of these new worlds. In order to interpret the spectra coming out by this new instrumentation, it is important to know in detail the optical characteristics of gases in the typical physical conditions of the planetary atmospheres and how those characteristics could be affected by radiation driven photochemical and bio-chemical reaction. Insights in this direction can be achieved from laboratory studies of simulated planetary atmosphere of different pressure and temperature conditions under the effects of radiation sources, used as proxies of different bands of the stellar emission. ''Atmosphere in a Test Tube'' is a collaboration among several Italian astronomical, biological and engineering institutes in order to share their experiencece in performing laboratory experiments on several items concerning extrasolar planet atmospheres.

  10. Tube Formation in Nanoscale Materials

    Directory of Open Access Journals (Sweden)

    Yan Chenglin

    2008-01-01

    Full Text Available Abstract The formation of tubular nanostructures normally requires layered, anisotropic, or pseudo-layered crystal structures, while inorganic compounds typically do not possess such structures, inorganic nanotubes thus have been a hot topic in the past decade. In this article, we review recent research activities on nanotubes fabrication and focus on three novel synthetic strategies for generating nanotubes from inorganic materials that do not have a layered structure. Specifically, thermal oxidation method based on gas–solid reaction to porous CuO nanotubes has been successfully established, semiconductor ZnS and Nb2O5nanotubes have been prepared by employing sacrificial template strategy based on liquid–solid reaction, and an in situ template method has been developed for the preparation of ZnO taper tubes through a chemical etching reaction. We have described the nanotube formation processes and illustrated the detailed key factors during their growth. The proposed mechanisms are presented for nanotube fabrication and the important pioneering studies are discussed on the rational design and fabrication of functional materials with tubular structures. It is the intention of this contribution to provide a brief account of these research activities.

  11. Steam generator tubing NDE performance

    Energy Technology Data Exchange (ETDEWEB)

    Henry, G. [Electric Power Research Institute, Charlotte, NC (United States); Welty, C.S. Jr. [Electric Power Research Institute, Palo Alto, CA (United States)

    1997-02-01

    Steam generator (SG) non-destructive examination (NDE) is a fundamental element in the broader SG in-service inspection (ISI) process, a cornerstone in the management of PWR steam generators. Based on objective performance measures (tube leak forced outages and SG-related capacity factor loss), ISI performance has shown a continually improving trend over the years. Performance of the NDE element is a function of the fundamental capability of the technique, and the ability of the analysis portion of the process in field implementation of the technique. The technology continues to improve in several areas, e.g. system sensitivity, data collection rates, probe/coil design, and data analysis software. With these improvements comes the attendant requirement for qualification of the technique on the damage form(s) to which it will be applied, and for training and qualification of the data analysis element of the ISI process on the field implementation of the technique. The introduction of data transfer via fiber optic line allows for remote data acquisition and analysis, thus improving the efficiency of analysis for a limited pool of data analysts. This paper provides an overview of the current status of SG NDE, and identifies several important issues to be addressed.

  12. Resonant oscillations in open axisymmetric tubes

    Science.gov (United States)

    Amundsen, D. E.; Mortell, M. P.; Seymour, B. R.

    2017-12-01

    We study the behaviour of the isentropic flow of a gas in both a straight tube of constant cross section and a cone, open at one end and forced at or near resonance at the other. A continuous transition between these configurations is provided through the introduction of a geometric parameter k associated with the opening angle of the cone where the tube corresponds to k=0. The primary objective is to find long-time resonant and near-resonant approximate solutions for the open tube, i.e. k→ 0. Detailed analysis for both the tube and cone in the limit of small forcing (O(ɛ 3)) is carried out, where ɛ 3 is the Mach number of the forcing function and the resulting flow has Mach number O(ɛ ). The resulting approximate solutions are compared with full numerical simulations. Interesting distinctions between the cone and the tube emerge. Depending on the damping and detuning, the responses for the tube are continuous and of O(ɛ ). In the case of the cone, the resonant response involves an amplification of the fundamental resonant mode, usually called the dominant first-mode approximation. However, higher modes must be included for the tube to account for the nonlinear generation of higher-order resonances. Bridging these distinct solution behaviours is a transition layer of O(ɛ 2) in k. It is found that an appropriately truncated set of modes provides the requisite modal approximation, again comparing well to numerical simulations.

  13. Dynamic tube movement of Ahmed glaucoma valve.

    Science.gov (United States)

    Law, Simon K; Coleman, Anne L; Caprioli, Joseph

    2009-01-01

    To report the dynamic movement of the tube of the Ahmed glaucoma valve (AGV) in the anterior chamber with eye movement. Three patients (eyes) with dynamic movement of the tube of the AGV out of approximately 1500 AGV implantations over 10 years were identified. Demographic information, management, and patient outcomes were abstracted from the medical records. Possible mechanisms of the tube movement are discussed. In all 3 eyes, the fibrovascular capsule and the plate were noted to be stationary in the superior temporal fornix under the conjunctiva and did not move with movement of the eye. The length of the intraocular portion of the tube varied between 3 and 4 mm, depending on the position of the globe. All 3 eyes had undergone at least 1 intraocular procedure before AGV implantation and 2 of 3 eyes had at least 1 intraocular procedure after the AGV implantation. The dynamic movement of the tube was first observed from 0.5 to 7 years after the AGVs were implanted. It was not associated with any intraocular reaction, damage of intraocular tissue, or decrease of intraocular pressure control, and no additional surgical intervention has been required. Dynamic movement of the tube of AGV results from dissociation of the fibrovascular capsule and the plate in the fornix from the rotation of the globe. The length of the intraocular portion of the tube may vary widely with eye movement.

  14. Miniature acoustic guidance system for endotracheal tubes

    Science.gov (United States)

    Juan, Eduardo J.

    Ensuring that the distal end of an endotracheal tube is properly located within the trachea, and that the tube is not obstructed by mucous deposition, is a major clinical concern in patients that require mechanical ventilation. A novel acoustic system was developed to allow for the continuous monitoring of endotracheal tube position and patency. A miniature sound source and two sensing microphones are placed in-line between the ventilator hose and the proximal end of the endotracheal tube. Reflections of an acoustic pulse from the endotracheal tube lumen and the airways are digitally analyzed to estimate the location and degree of obstruction, as well as the position of the distal end of the tube in the airway. The system was evaluated through computer simulations, in vitro studies, and in a rabbit model. The system noninvasively estimated tube position in vivo to within roughly 4.5 mm, and differentiated between proper tracheal, and erroneous bronchial or esophageal intubation in all cases. In addition, the system estimated the area and location of lumen obstructions in vitro to within 14% and 3.5 mm, respectively. These findings indicate that this miniature technology could improve the quality of care provided to the ventilated adult and infant.

  15. Stroke: Ineffective tube securement reduces nutrition and drug treatment

    OpenAIRE

    Brazier, S.; Taylor, S.J.; Allan, K; R. Clemente; Toher, D.

    2017-01-01

    Stroke patients with dysphagia often depend on nutrition, hydration and medication via nasogastric (NG) feeding tubes. Securing tubes using tape was associated with repeated tube loss. We determined cause and effect by auditing tube placement methods, delays incurred, duration and costs. Of 202 NG tube placements in 75 patients, 67 placements occurred in 17 patients over a full course of enteral nutrition (EN) and 40 of these placements were tracked. Tubes were secured by tape in 100%, mitten...

  16. Development of inconel alloys precision tube

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young-Hee; Lee, D. H.; Shin, Y. S.; Park, J. H. [Changwon Speciality Steel Co., Ltd., Changwon (Korea); Kim, J. S.; Kim, H. P; Lim, Y. S.; Hwang, S. S.; Jung, M. K.; Woo, Y. M.; Han, C. H. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    1998-04-01

    The purpose of this research is to investigate the mass production facility and evaluation of profitability for steam generator tubing in nuclear power plant. The equipment requirement and capacity, total investment cost, the evaluation of mass production yield and production cost accounting, the manufacturing technique standardization have been investigated. According to the result of evaluation of profitability, the project for SG tubing will be difficult to commercialize, but it can be considered the re-commercialize when the condition for investment is improving. The results of this research can be applicated to commercialize the precision tubes manufacturing which require similar process. 17 refs., 7 figs., 21 tabs. (Author)

  17. Noninflammatory fallopian tube pathology in children

    Energy Technology Data Exchange (ETDEWEB)

    Merlini, Laura; Anooshiravani, Mehrak; Hanquinet, Sylviane [University Hospital HUG, Unit of Pediatric Radiology, Geneva (Switzerland); Vunda, Aaron [University Hospital, Clinic of Pediatric Surgery, Geneva (Switzerland); Borzani, Irene; Napolitano, Marcello [Ospedale Buzzi, Pediatric Radiology, Milan (Italy)

    2008-12-15

    Noninflammatory tubal abnormalities are rare in children and usually not well covered by traditional educational material. The presenting symptoms are nonspecific and are common to many other conditions, so its preoperative diagnosis is rarely made. The purpose of this study was to review the hospital charts and imaging findings in children and sexually inactive adolescents who showed fallopian tube pathology. Understanding of the pertinent findings of previous imaging examinations might assist radiologists in making the correct preoperative diagnosis and increase the likelihood of preserving the fallopian tubes. The clinical entities described in this article include isolated tubal torsion, paratubal cysts, hydrosalpinx, undescended/ectopic fallopian tube, and tubal inguinal hernia. (orig.)

  18. Nervous system examination on YouTube

    OpenAIRE

    Azer Samy A; AlEshaiwi Sarah M; AlGrain Hala A; AlKhelaif Rana A

    2012-01-01

    Abstract Background Web 2.0 sites such as YouTube have become a useful resource for knowledge and are used by medical students as a learning resource. This study aimed at assessing videos covering the nervous system examination on YouTube. Methods A research of YouTube was conducted from 2 November to 2 December 2011 using the following key words “nervous system examination”, “nervous system clinical examination”, “cranial nerves examination”, “CNS examination”, “examination of cerebellum”, “...

  19. Air Liquide Space Pulse Tube Cryocoolers

    Science.gov (United States)

    Tanchon, J.; Trollier, T.; Buquet, J.; Ravex, A.; Crespi, P.

    2008-03-01

    Thanks to important internal development efforts completed and partial ESA funding, AL/DTA is now in position to propose two Pulse Tube cooler systems in the 40-80K temperature range for coming Earth Observation missions such as MTG, Sentinel 3, etc… The two pulse tube coolers thermo-mechanical units have been qualified against thermal and mechanical environment constraints. To complete these two Pulse Tube coolers, a Cooler Drive Electronic has been developed for active damping and vibration cancellation. The paper presents the current status of these products and associated Cooler Drive Electronics.

  20. Influence of furnace tube shapeon thermal strain of fire-tube boilers

    Directory of Open Access Journals (Sweden)

    Gaćeša Branka

    2014-01-01

    Full Text Available The aim of this paper is to use numerical analysis and fine element method-FEM to investigate the influence of furnace tube shape on the thermal strain of fire-tube boilers. Thermal stresses in corrugated furnace tubes of different shape, i.e. with different corrugation pitch and depth, were analysed first. It was demonstrated that the thermal stresses in corrugated furnace tube are significantly reduced with the increase of corrugation depth. Than deformations and stresses in the structure of a fire-tube boiler were analysed in a real operating condition, for the cases of installed plain furnace tube and corrugated furnace tubes with different shapes. It was concluded that in this fire-tube boiler, which is of larger steam capacity, the corrugated furnace tube must be installed, as well as that the maximal stress in the construction is reduced by the installation of the furnace tube with greater corrugation depth. The analysis of stresses due to pressure and thermal loads pointed out that thermal stresses are not lower-order stresses in comparison to stresses due to pressure loads, so they must be taken into consideration for boiler strength analysis. [Projekat Ministarstva nauke Republike Srbije, br. TR 35040 i br. TR 35011

  1. EFFECT OF TUBE PITCH ON HEAR TRANSFER IN SPRINKLED TUBE BUNDLE

    Directory of Open Access Journals (Sweden)

    Petr Kracík

    2015-10-01

    Full Text Available Water flowing on a sprinkled tube bundle forms three basic modes: the Droplet mode (the liquid drips from one tube to another, the Jet mode (with an increasing flow rate, the droplets merge into a column and the Membrane (Sheet mode (with a further increase in the flow rate of the falling film liquid, the columns merge and create sheets between the tubes. With a sufficient flow rate, the sheets merge at this stage, and the tube bundle is completely covered by a thin liquid film. There are several factors influencing both the individual modes and the heat transfer. Beside the above-mentioned falling film liquid flow rate, these are for instance the tube diameters, the tube pitches in the tube bundle, or the physical conditions of the falling film liquid. This paper presents a summary of data measured at atmospheric pressure, with a tube bundle consisting of copper tubes of 12 millimetres in diameter, and with a studied tube length of one meter. The tubes are situated horizontally one above another at a pitch of 15 to 30 mm, and there is a distribution tube placed above them with water flowing through apertures of 1.0mm in diameter at a 9.2mm span. Two thermal conditions have been tested with all pitches: 15 °C to 40 °C and 15 °C to 45 °C. The temperature of the falling film liquid, which was heated during the flow through the exchanger, was 15 °C at the distribution tube input. The temperature of the heating liquid at the exchanger input, which had a constant flow rate of approx. 7.2. litres per minute, was 40 °C, or alternatively 45 °C.

  2. A reduction of the saddle vertical force triggers the sit-stand transition in cycling.

    Science.gov (United States)

    Costes, Antony; Turpin, Nicolas A; Villeger, David; Moretto, Pierre; Watier, Bruno

    2015-09-18

    The purpose of the study was to establish the link between the saddle vertical force and its determinants in order to establish the strategies that could trigger the sit-stand transition. We hypothesized that the minimum saddle vertical force would be a critical parameter influencing the sit-stand transition during cycling. Twenty-five non-cyclists were asked to pedal at six different power outputs from 20% (1.6 ± 0.3 W kg(-1)) to 120% (9.6 ± 1.6 W kg(-1)) of their spontaneous sit-stand transition power obtained at 90 rpm. Five 6-component sensors (saddle tube, pedals and handlebars) and a full-body kinematic reconstruction were used to provide the saddle vertical force and other force components (trunk inertial force, hips and shoulders reaction forces, and trunk weight) linked to the saddle vertical force. Minimum saddle vertical force linearly decreased with power output by 87% from a static position on the bicycle (5.30 ± 0.50 N kg(-1)) to power output=120% of the sit-stand transition power (0.68 ± 0.49 N kg(-1)). This decrease was mainly explained by the increase in instantaneous pedal forces from 2.84 ± 0.58 N kg(-1) to 6.57 ± 1.02 N kg(-1) from 20% to 120% of the power output corresponding to the sit-stand transition, causing an increase in hip vertical forces from -0.17 N kg(-1) to 3.29 N kg(-1). The emergence of strategies aiming at counteracting the elevation of the trunk (handlebars and pedals pulling) coincided with the spontaneous sit-stand transition power. The present data suggest that the large decrease in minimum saddle vertical force observed at high pedal reaction forces might trigger the sit-stand transition in cycling. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Lidar measured vertical atmospheric scattering profiles

    NARCIS (Netherlands)

    Kunz, G.J.

    1985-01-01

    The vertical structure of the atmosphere, which is of invaluable interest to meteorologists, geo-physicists and environmental researchers, can be measured with LIDAR. A method has been proposed and applied to invert lidar signals from vertical soundings to height resolved scattering coefficients. In

  4. Vertical integration from the large Hilbert space

    Science.gov (United States)

    Erler, Theodore; Konopka, Sebastian

    2017-12-01

    We develop an alternative description of the procedure of vertical integration based on the observation that amplitudes can be written in BRST exact form in the large Hilbert space. We relate this approach to the description of vertical integration given by Sen and Witten.

  5. Plasmon Modes of Vertically Aligned Superlattices

    DEFF Research Database (Denmark)

    Filonenko, Konstantin; Duggen, Lars; Willatzen, Morten

    2017-01-01

    By using the Finite Element Method we visualize the modes of vertically aligned superlattice composed of gold and dielectric nanocylinders and investigate the emitter-plasmon interaction in approximation of weak coupling. We find that truncated vertically aligned superlattice can function as plas...

  6. A vertically resolved model for phytoplankton aggregation

    Indian Academy of Sciences (India)

    components undergo vertical mixing, and phytoplank- ton sink. Phytoplankton growth is limited by the product of nutrient and light terms. The equations for nitrate (NO3) and ... resolved model there is an extra complication: the largest particles that sink out of ...... and biogeochemistry with satellite ocean colour data. Vertically ...

  7. Plasmon Modes of Vertically Aligned Superlattices

    DEFF Research Database (Denmark)

    Filonenko, Konstantin; Duggen, Lars; Willatzen, Morten

    By using the Finite Element Method we visualize the modes of vertically aligned superlattice composed of gold and dielectric nanocylinders and investigate the emitter-plasmon interaction in approximation of weak coupling. We find that truncated vertically aligned superlattice can function as plas...

  8. DESIGN, CONSTRUCTION AND EVALUATION OF A VERTICAL ...

    African Journals Online (AJOL)

    Vertical plate metering device is intended to minimize seed damage during planting while improving metering efficiency and field capacity. A vertical plate maize seed planter which is adapted for gardens and small holder farmers cultivating less than two hectares has been designed, constructed and tested. The major ...

  9. The green building envelope : Vertical greening

    NARCIS (Netherlands)

    Ottelé, M.

    2011-01-01

    Planting on roofs and façades is one of the most innovative and fastest developing fields of green technologies with respect to the built environment and horticulture. This thesis is focused on vertical greening of structures and to the multi-scale benefits of vegetation. Vertical green can improve

  10. Vertical Integration, Monopoly, and the First Amendment.

    Science.gov (United States)

    Brennan, Timothy J.

    This paper addresses the relationship between the First Amendment, monopoly of transmission media, and vertical integration of transmission and content provision. A survey of some of the incentives a profit-maximizing transmission monopolist may have with respect to content is followed by a discussion of how vertical integration affects those…

  11. Experimental and visual study on flow patterns and pressure drops in U-tubes

    Energy Technology Data Exchange (ETDEWEB)

    Da Silva Lima, J. R.

    2011-07-01

    In single- and two-phase flow heat exchangers (in particular 'coils'), besides the straight tubes there are also many singularities, in particular the 180° return bends (also called return bends or U-bends). However, contrary to the literature concerning pressure drops and heat transfer in straight tubes, where many experimental data and predicting methods are available, only a limited number of studies concerning U-bends can be found. Neither reliable experimental data nor proven prediction methods are available. Indeed, flow structure, pressure drop and heat transfer in U-bends are an old unresolved design problem in the heat transfer industry. Thus, the present study aims at providing further insight on two-phase pressure drops and flows patterns in U-bends. Based on a new type of U-bend test section, an extensive experimental study was conducted. The experimental campaign covered five test sections with three internal diameters (7.8, 10.8 and 13.4 mm), five bend diameters (24.8, 31.7, 38.1, 54.8 and 66.1 mm), tested for three orientations (horizontal, vertical upflow and vertical downflow), two fluids (R134a and R410A), two saturation temperatures (5 and 10 °C) and mass velocities ranging from 150 to 1000 kg s{sup -1} m{sup -2}. The flow pattern observations identified were stratified-wavy, slug-stratified-wavy, intermittent, annular, dryout and mist flows. The effects of the U-bend on the flow patterns were also observed. A total of 5655 pressure drop data were measured at seven different locations in the test section ( straight tubes and U-bend) providing a total of almost 40,000 data points. The straight tube data were first used to improve the actual two-phase straight tube model of Moreno-Quibén and Thome. This updated model was then used to developed a two-phase U-bend pressure drop model. Based on a comparison between experimental and predicted values, it is concluded that the new two-phase frictional pressure drop model for U

  12. An experimental investigation on air-side performances of finned tube heat exchangers for indirect air-cooling tower

    Directory of Open Access Journals (Sweden)

    Du Xueping

    2014-01-01

    Full Text Available A tremendous quantity of water can be saved if the air cooling system is used, comparing with the ordinary water-cooling technology. In this study, two kinds of finned tube heat exchangers in an indirect air-cooling tower are experimentally studied, which are a plain finned oval-tube heat exchanger and a wavy-finned flat-tube heat exchanger in a cross flow of air. Four different air inlet angles (90°, 60 °, 45°, and 30° are tested separately to obtain the heat transfer and resistance performance. Then the air-side experimental correlations of the Nusselt number and friction factor are acquired. The comprehensive heat transfer performances for two finned tube heat exchangers under four air inlet angles are compared. For the plain finned oval-tube heat exchanger, the vertical angle (90° has the worst performance while 45° and 30° has the best performance at small ReDc and at large ReDc, respectively. For the wavy-finned flat-tube heat exchanger, the worst performance occurred at 60°, while the best performance occurred at 45° and 90° at small ReDc and at large ReDc, respectively. From the comparative results, it can be found that the air inlet angle has completely different effects on the comprehensive heat transfer performance for the heat exchangers with different structures.

  13. Development of Radar Navigation and Radio Data Transmission for Microhole Coiled Tubing Bottom Hole Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Larry G. Stolarczyk; Gerald L. Stolarczyk; Larry Icerman; John Howard; Hooman Tehrani

    2007-03-25

    This Final Technical Report summarizes the research and development (R&D) work performed by Stolar Research Corporation (Stolar) under U.S. Department of Energy (DOE) Contract Number DE-FC26-04NT15477. This work involved the development of radar navigation and radio data transmission systems for integration with microhole coiled tubing bottom hole assemblies. Under this contract, Stolar designed, fabricated, and laboratory and field tested two advanced technologies of importance to the future growth of the U.S. oil and gas industry: (1) real-time measurement-while-drilling (MWD) for guidance and navigation of coiled tubing drilling in hydrocarbon reservoirs and (2) two-way inductive radio data transmission on coiled tubing for real-time, subsurface-to-surface data transmission. The operating specifications for these technologies are compatible with 3.5-inch boreholes drilled to a true vertical depth (TVD) of 5,000 feet, which is typical of coiled tubing drilling applications. These two technologies (i.e., the Stolar Data Transmission System and Drill String Radar) were developed into pre-commercial prototypes and tested successfully in simulated coiled tubing drilling conditions. Integration of these two technologies provides a real-time geosteering capability with extremely quick response times. Stolar is conducting additional work required to transition the Drill String Radar into a true commercial product. The results of this advanced development work should be an important step in the expanded commercialization of advanced coiled tubing microhole drilling equipment for use in U.S. hydrocarbon reservoirs.

  14. Influence of packing density and surface roughness of vertically-aligned carbon nanotubes on adhesive properties of gecko-inspired mimetics.

    Science.gov (United States)

    Chen, Bingan; Zhong, Guofang; Oppenheimer, Pola Goldberg; Zhang, Can; Tornatzky, Hans; Esconjauregui, Santiago; Hofmann, Stephan; Robertson, John

    2015-02-18

    We have systematically studied the macroscopic adhesive properties of vertically aligned nanotube arrays with various packing density and roughness. Using a tensile setup in shear and normal adhesion, we find that there exists a maximum packing density for nanotube arrays to have adhesive properties. Too highly packed tubes do not offer intertube space for tube bending and side-wall contact to surfaces, thus exhibiting no adhesive properties. Likewise, we also show that the surface roughness of the arrays strongly influences the adhesion properties and the reusability of the tubes. Increasing the surface roughness of the array strengthens the adhesion in the normal direction, but weakens it in the shear direction. Altogether, these results allow progress toward mimicking the gecko's vertical mobility.

  15. Experimental studies on the evaporative heat transfer and pressure drop of CO{sub 2} and CO{sub 2}/propane mixtures flowing upward in smooth and micro-fin tubes with outer diameter of 5 mm for an inclination angle of 45

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jin Min; Kim, Min Soo [School of Mechanical and Aerospace Engineering, Seoul National University, Seoul 151-744 (Korea); Kim, Yong Jin [School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2010-08-15

    Heat transfer characteristics show different tendency according to the tube orientations such as horizontal, vertical, and inclined positions. In this study, evaporative heat transfer characteristics and pressure drop of CO{sub 2} and CO{sub 2}/propane mixtures flowing upward are investigated in inclined smooth and micro-fin tubes. Smooth and micro-fin tubes with outer diameter of 5 mm and length of 1.44 m with inclination angle of 45 were chosen as test tubes. Average inner diameters of test tubes are 4.0 mm (smooth tube) and 4.13 mm (micro-fin tube). The tests were conducted at mass fluxes from 212 to 656 kg/m{sup 2} s, saturation temperatures from -10 to 30 C and heat fluxes from 15 to 60 kW/m{sup 2} for CO{sub 2}. In addition, for CO{sub 2}/propane mixtures, the test was carried out at inlet temperatures from -10 to 30 C for several compositions (75/25, 50/50, 25/75 wt%) with the same mass fluxes, heat fluxes applied for CO{sub 2}. Heat transfer coefficients in inclined tube are approximately 1.8-3 times higher than those in horizontal tube and the average pressure drop of inclined tube exists between that of horizontal and vertical tubes. (author)

  16. Pneumatosis intestinalis associated with enteral tube feeding

    National Research Council Canada - National Science Library

    Zorgdrager, Marcel; Pol, Robert

    2013-01-01

    ...). Explorative laparotomy showed an omental band adhesion without signs of ischaemia. After a short period of total parenteral nutrition PI resolved almost completely and enteral tube feeding could be continued once again...

  17. Automatic welding of stainless steel tubing

    Science.gov (United States)

    Clautice, W. E.

    1978-01-01

    The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.

  18. Caring for Your Percutaneous Nephrostomy Tube

    Science.gov (United States)

    ... and medication through this line.  You will be awake, relaxed, and maybe a little sleepy during the ... tube.  If you have low urine output or dark, foul- Patient Information Procedure 1. Thoroughly wash your ...

  19. Screening for Open Neural Tube Defects.

    Science.gov (United States)

    Krantz, David A; Hallahan, Terrence W; Carmichael, Jonathan B

    2016-06-01

    Biochemical prenatal screening was initiated with the use of maternal serum alpha fetoprotein to screen for open neural tube defects. Screening now includes multiple marker and sequential screening protocols involving serum and ultrasound markers to screen for aneuploidy. Recently cell-free DNA screening for aneuploidy has been initiated, but does not screen for neural tube defects. Although ultrasound is highly effective in identifying neural tube defects in high-risk populations, in decentralized health systems maternal serum screening still plays a significant role. Abnormal maternal serum alpha fetoprotein alone or in combination with other markers may indicate adverse pregnancy outcome in the absence of open neural tube defects. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. The Choking Game on YouTube

    Directory of Open Access Journals (Sweden)

    Ellen K. Defenderfer MS

    2016-03-01

    Full Text Available The choking game (TCG is an adolescent activity in which asphyxiation is used to obtain a “high,” occasionally resulting in seizures or death. A plethora of TCG information is available through YouTube, though this content has not been evaluated recently. The current study described TCG as portrayed in YouTube videos and compared views and ratings of TCG videos to unrelated videos. The TCG videos demonstrated diverse methods of asphyxiation, with a minority showing injury to the participants. TCG videos were less likely to be commented on or rated positively than non–choking game videos. TCG prevention videos differed significantly from actual TCG videos in the way they depicted the social context of TCG. Thus, TCG videos are accessible through YouTube, but the prevention materials available on YouTube are not accurate or representative. Accurate and educational online prevention materials should be created to decrease the occurrence of TCG.

  1. Multimode Traveling-Wave Amplifier Tubes

    Science.gov (United States)

    Buck, E.

    1981-02-01

    The paper examines the recent developments which makes the Traveling Wave Tube (TWT) more powerful and efficient as a microwave amplifier than the solid state devices. Basic workings and efficiency, which can run, but usually do not, to 55%, are examined. The dependence of the performance of a given TWT upon the qualities of the beam and the manner of its focusing is described. Also described is the development of a multistage depressed collector (MDC) and its first application to a Communication Technology Satellite (CTS) tube, a 12 GHz, coupled-cavity, 200 watt TWT, which resulted in being operated in space for nearly four years and was both the most powerful and the most efficient (around 50%) communications TWT ever flown. It is predicted that the application of efficient refocusing and MDCs, made possible by computer simulations, will greatly increase tube efficiency, and thereby make practical, new multimode tubes which operate, as least partly, in a linear fashion.

  2. Gastroenteric tube feeding: Techniques, problems and solutions

    National Research Council Canada - National Science Library

    Irina Blumenstein Yogesh M Shastri Jürgen Stein

    2014-01-01

    Gastroenteric tube feeding plays a major role in the management of patients with poor voluntary intake,chronic neurological or mechanical dysphagia or gut dysfunction,and patients who are critically...

  3. Medical Informatics Idle YouTube Potential.

    Science.gov (United States)

    Hucíková, Anežka; Babic, Ankica

    2017-01-01

    YouTube as an online video-sharing service in the context of Web 2.0 goes beyond the bounds of pure fun, for which the platform was primarily established. Nowadays, commonly to other social media, it serves also educational, informational and last but not least, marketing purposes. The importance of video sharing is supported by several predictions about video reaching over 90% of global internet traffic by 2020. Using qualitative content analysis over selected YouTube videos, paper examines the current situation of the platform's marketing potential usage by medical informatics organizations, researches and other healthcare professionals. Results of the analysis demonstrate several ways in which YouTube is already used to inform, educate or promote above-mentioned medical institutions. However, their engagement in self-promo or spreading awareness of their research projects via YouTube is considered to be low.

  4. YouTube and ‘psychiatry’

    Science.gov (United States)

    Gordon, Robert; Miller, John; Collins, Noel

    2015-01-01

    YouTube is a video-sharing website that is increasingly used to share and disseminate health-related information, particularly among younger people. There are reports that social media sites, such as YouTube, are being used to communicate an anti-psychiatry message but this has never been confirmed in any published analysis of YouTube clip content. This descriptive study revealed that the representation of ‘psychiatry’ during summer 2012 was predominantly negative. A subsequent smaller re-analysis suggests that the negative portrayal of ‘psychiatry’ on YouTube is a stable phenomenon. The significance of this and how it could be addressed are discussed. PMID:26755987

  5. A review of pulse tube refrigeration

    Science.gov (United States)

    Radebaugh, Ray

    1990-01-01

    This paper reviews the development of the three types of pulse tube refrigerators: basic, resonant, and orifice types. The principles of operation are given. It is shown that the pulse tube refrigerator is a variation of the Stirling-cycle refrigerator, where the moving displacer is substituted by a heat transfer mechanism or by an orifice to bring about the proper phase shifts between pressure and mass flow rate. A harmonic analysis with phasors is described which gives reasonable results for the refrigeration power, yet is simple enough to make clear the processes which give rise to the refrigeration. The efficiency and refrigeration power are compared with those of other refrigeration cycles. A brief review is given of the research being done at various laboratories on both one- and two-stage pulse tubes. A preliminary assessment of the role of pulse tube refrigerators is discussed.

  6. Opioid Use and Neural Tube Defects

    Science.gov (United States)

    ... CDC.gov . Error processing SSI file Key Findings: Opioid Use and Neural Tube Defects Recommend on Facebook ... new study that looked at the use of opioids during pregnancy and their relationship to having a ...

  7. Routine jejunostomy tube feeding following esophagectomy

    National Research Council Canada - National Science Library

    Weijs, Teus J; van Eden, Hanneke W.J; Ruurda, Jelle P.|info:eu-repo/dai/nl/257561021; Luyer, Misha D P; Steenhagen, Elles|info:eu-repo/dai/nl/304815713; Nieuwenhuijzen, Grard A P; van Hillegersberg, Richard|info:eu-repo/dai/nl/110706242

    2017-01-01

    Background: Malnutrition is an important problem following esophagectomy. A surgically placed jejunostomy secures an enteral feeding route, facilitating discharge with home-tube feeding and long-term nutritional support...

  8. Accidental Decannulation OF TRACHEOSTOMY TUBES - Case Series.

    Science.gov (United States)

    Omokanye, H K; Dunmade, A D; Segun-Busari, S; Afolabi, O A; Habeeb, O G; Adegboye, M B; Alabi, B S

    2016-01-01

    Tracheostomy tube (TT) is usually removed in a planned manner once the patient ceases to have the condition that necessitated the procedure. Accidental decannulation or extubation refers to inadvertent removal of tracheostomy tube out of the stoma. It could prove fatal in an otherwise stable patient. We review a variety of unexpected and often-overlooked causes of accidental decannulation with suggestions on preventive measures. We therefore present three cases of accidental decannulation of tracheostomy tubes in order to report our experiences in the management of the condition. Accidental decannulation occurs both in hospitalized and patient on home care of their tracheostomy tubes. Reduction in neck circumference due to weight loss predisposes to accidental decannulation, which could be prevented by suturing the flange to the skin.

  9. Stabilization Strategies for Drift Tube Linacs

    CERN Document Server

    AUTHOR|(CDS)2085420; Lamehi Rashti, Mohammad

    The average axial electric fields in drift tube linac cavities are known to be sensitive with respect to the perturbation errors. Postcoupler is a powerful stabilizer devices that is used to reduce this sensitivity of average axial field. Postcouplers are the cylindrical rod which is extended from cavity wall toward the drift tube without touching the drift tube surface. Postcouplers need to be adjusted to the right length to stabilize the average axial field. Although postcouplers are used successfully in many projects, there is no straightforward procedure for postcouplers adjustment and it has been done almost based on trial and errors. In this thesis, the physics and characteristics of postcouplers has been studied by using an equivalent circuit model and 3D finite element method calculations. Finally, a straightforward and accurate method to adjust postcouplers has been concluded. The method has been verified by using experimental measurements on CERN Linac4 drift tube linac cavities.

  10. SPECIAL PURPOSE SHOCK TUBE for BLAST ASSESSMENT

    Data.gov (United States)

    Federal Laboratory Consortium — This device is a specially designed shock tube for testing fabric samples in a controlled environment. The device determines the appropriate types of sensors to be...

  11. Metal bellows custom-fabricated from tubing

    Science.gov (United States)

    1965-01-01

    Mandrel assembly mounted in a lathe chuck is used with a forming wheel to roll-form bellows from standard sheet metal tubing. Spacers and mandrels of various sizes custom-fabricate bellows of any desired dimensions.

  12. Inverse Kinematics of Concentric Tube Steerable Needles.

    Science.gov (United States)

    Sears, Patrick; Dupont, Pierre E

    2007-01-01

    Prior papers have introduced steerable needles composed of precurved concentric tubes. The curvature and extent of these needles can be controlled by the relative rotation and translation of the individual tubes. Under certain assumptions on the geometry and design of these needles, the forward kinematics problem can be solved in closed form by means of algebraic equations. The inverse kinematics problem, however, is not as straightforward owing to the nonlinear map between relative tube displacements and needle tip configuration as well as to the multiplicity of solutions as the number of tubes increases. This paper presents a general approach to solving the inverse kinematics problem using a pseudoinverse solution together with gradients of nullspace potential functions to enforce geometric and mechanical constraints.

  13. Optimizing Tube Precurvature to Enhance Elastic Stability of Concentric Tube Robots.

    Science.gov (United States)

    Ha, Junhyoung; Park, Frank C; Dupont, Pierre E

    2017-02-01

    Robotic instruments based on concentric tube technology are well suited to minimally invasive surgery since they are slender, can navigate inside small cavities and can reach around sensitive tissues by taking on shapes of varying curvature. Elastic instabilities can arise, however, when rotating one precurved tube inside another. In contrast to prior work that considered only tubes of piecewise constant precurvature, we allow precurvature to vary along the tube's arc length. Stability conditions for a planar tube pair are derived and used to formulate an optimal design problem. An analytic formulation of the optimal precurvature function is derived that achieves a desired tip orientation range while maximizing stability and respecting bending strain limits. This formulation also includes straight transmission segments at the proximal ends of the tubes. The result, confirmed by both numerical and physical experiment, enables designs with enhanced stability in comparison to designs of constant precurvature.

  14. Optical properties of ordered vertical arrays of multi-walled carbon nanotubes from FDTD simulations.

    Science.gov (United States)

    Bao, Hua; Ruan, Xiulin; Fisher, Timothy S

    2010-03-15

    A finite-difference time-domain (FDTD) method is used to model thermal radiative properties of vertical arrays of multi-walled carbon nanotubes (MWCNT). Individual CNTs are treated as solid circular cylinders with an effective dielectric tensor. Consistent with experiments, the results confirm that CNT arrays are highly absorptive. Compared with the commonly used Maxwell-Garnett theory, the FDTD calculations generally predict larger reflectance and absorbance, and smaller transmittance, which are attributed to the diffraction and scattering within the cylinder array structure. The effects of volume fraction, tube length, tube distance, and incident angle on radiative properties are investigated systematically. Low volume fraction and long tubes are more favorable to achieve low reflectance and high absorbance. For a fixed volume fraction and finite tube length, larger periodicity results in larger reflectance and absorbance. The angular dependence studies reveal an optimum incident angle at which the reflectance can be minimized. The results also suggest that an even darker material could be achieved by using CNTs with good alignment on the top surface.

  15. SNORKEL TRACHEOTOMY TUBE FOR RESPIRATOR USE

    Science.gov (United States)

    Lebo, Charles P.

    1954-01-01

    The Snorkel tracheotomy tube, a simple modification of the standard tube, overcomes many of the mechanical inconveniences usually encountered in the care of patients with tracheotomy who have to be kept in respirators. With it in place, it is not necessary to use special devices to hold the collar of the respirator away from the site of the tracheal incision. Nursing care of the patient is made easier. ImagesFigure 2.Figure 3. PMID:13182610

  16. Accidental Decannulation OF TRACHEOSTOMY TUBES - Case Series

    OpenAIRE

    Omokanye, HK; Dunmade, AD; Segun-Busari, S; Afolabi, OA; Habeeb, OG; Adegboye, MB; Alabi, BS

    2016-01-01

    Tracheostomy tube (TT) is usually removed in a planned manner once the patient ceases to have the condition that necessitated the procedure. Accidental decannulation or extubation refers to inadvertent removal of tracheostomy tube out of the stoma. It could prove fatal in an otherwise stable patient. We review a variety of unexpected and often-overlooked causes of accidental decannulation with suggestions on preventive measures. We therefore present three cases of accidental decannulation of ...

  17. A Flue Gas Tube for Thermoelectric Generator

    DEFF Research Database (Denmark)

    2013-01-01

    The invention relates to a flue gas tube (FGT) (1) for generation of thermoelectric power having thermoelectric elements (8) that are integrated in the tube. The FTG may be used in combined heat and power (CHP) system (13) to produce directly electricity from waste heat from, e.g. a biomass boiler....... The CHP system may also be operated in a heating or cooling mode, thus being able to heat or cool water by feeding electricity to the system....

  18. Explosively Bonded Gun Tube Liner Development

    Science.gov (United States)

    2015-04-01

    some concern was the occasional appearance of iron-Ta intermetallics near the liner-steel interface. This is a brittle phase and subject to...Montgomery JS, de Rosset WS. Examination of intermetallic phases and residual stresses resulting from explosive bonding of refractory metal gun tube...caliber smoothbore gun tube. The metallic bond produced by explosive bonding is extremely strong and presumably would keep the liner in place. In Phase

  19. A singularity-free analytic solution of rise dynamics of a liquid in a vertical cylindrical capillary

    OpenAIRE

    Zhong, Xiaoxu; Sun, Bohua; Liao, Shijun

    2018-01-01

    Capillary driven flow is a famous problem in fluid dynamics which dates back to Leonardo da Vinci. In this paper, we apply an analytic approximation method for highly nonlinear problem, namely the homotopy analysis method (HAM), to a model of the meniscus movement in a uniform vertical circular tube. Convergent explicit series solution is successfully obtained. Our results agree well with the numerical results given by the symbolic computing software Mathematica using six-order Runge-Kutta me...

  20. A Computation Fluid Dynamic Model for Gas Lift Process Simulation in a Vertical Oil Well

    Directory of Open Access Journals (Sweden)

    Kadivar Arash

    2017-03-01

    Full Text Available Continuous gas-lift in a typical oil well was simulated using computational fluid dynamic (CFD technique. A multi fluid model based on the momentum transfer between liquid and gas bubbles was employed to simulate two-phase flow in a vertical pipe. The accuracy of the model was investigated through comparison of numerical predictions with experimental data. The model then was used to study the dynamic behaviour of the two-phase flow around injection point in details. The predictions by the model were compared with other empirical correlations, as well. To obtain an optimum condition of gas-lift, the influence of the effective parameters including the quantity of injected gas, tubing diameter and bubble size distribution were investigated. The results revealed that increasing tubing diameter, the injected gas rate and decreasing bubble diameter improve gas-lift performance.