WorldWideScience

Sample records for valve disease electronic

  1. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  2. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  3. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  4. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  5. Aortic Valve Disease

    Science.gov (United States)

    ... team will discuss with you the advantages and disadvantages of both valve types. Regardless of which type ... Diagnosis and Treatment Options Recovery Questions for Your Doctor Will my condition ever get better without treatment? ...

  6. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  7. Bicuspid Aortic Valve Disease: A Comprehensive Review

    OpenAIRE

    Mordi, Ify; Tzemos, Nikolaos

    2012-01-01

    Bicuspid aortic valve is the commonest congenital cardiac abnormality in the general population. This paper article will discuss our current knowledge of the anatomy, pathophysiology, genetics, and clinical aspects of bicuspid aortic valve disease.

  8. Heart valve disease among patients with hyperprolactinemia

    DEFF Research Database (Denmark)

    Steffensen, Maria Charlotte; Maegbaek, Merete Lund; Laurberg, Peter

    2012-01-01

    Increased risk of heart valve disease during treatment with certain dopamine agonists, such as cabergoline, has been observed in patients with Parkinson's disease. The same compound is used to treat hyperprolactinemia, but it is unknown whether this also associates with heart valve disease....

  9. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  10. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  11. Multimodality Imaging of Heart Valve Disease

    International Nuclear Information System (INIS)

    Rajani, Ronak; Khattar, Rajdeep; Chiribiri, Amedeo; Victor, Kelly; Chambers, John

    2014-01-01

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses

  12. Multimodality Imaging of Heart Valve Disease

    Energy Technology Data Exchange (ETDEWEB)

    Rajani, Ronak, E-mail: Dr.R.Rajani@gmail.com [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom); Khattar, Rajdeep [Department of Cardiology, Royal Brompton Hospital, London (United Kingdom); Chiribiri, Amedeo [Divisions of Imaging Sciences, The Rayne Institute, St. Thomas' Hospital, London (United Kingdom); Victor, Kelly; Chambers, John [Department of Cardiology, St. Thomas’ Hospital, London (United Kingdom)

    2014-09-15

    Unidentified heart valve disease is associated with a significant morbidity and mortality. It has therefore become important to accurately identify, assess and monitor patients with this condition in order that appropriate and timely intervention can occur. Although echocardiography has emerged as the predominant imaging modality for this purpose, recent advances in cardiac magnetic resonance and cardiac computed tomography indicate that they may have an important contribution to make. The current review describes the assessment of regurgitant and stenotic heart valves by multimodality imaging (echocardiography, cardiac computed tomography and cardiac magnetic resonance) and discusses their relative strengths and weaknesses.

  13. Simple versus complex degenerative mitral valve disease.

    Science.gov (United States)

    Javadikasgari, Hoda; Mihaljevic, Tomislav; Suri, Rakesh M; Svensson, Lars G; Navia, Jose L; Wang, Robert Z; Tappuni, Bassman; Lowry, Ashley M; McCurry, Kenneth R; Blackstone, Eugene H; Desai, Milind Y; Mick, Stephanie L; Gillinov, A Marc

    2018-07-01

    At a center where surgeons favor mitral valve (MV) repair for all subsets of leaflet prolapse, we compared results of patients undergoing repair for simple versus complex degenerative MV disease. From January 1985 to January 2016, 6153 patients underwent primary isolated MV repair for degenerative disease, 3101 patients underwent primary isolated MV repair for simple disease (posterior prolapse), and 3052 patients underwent primary isolated MV repair for complex disease (anterior or bileaflet prolapse), based on preoperative echocardiographic images. Logistic regression analysis was used to generate propensity scores for risk-adjusted comparisons (n = 2065 matched pairs). Durability was assessed by longitudinal recurrence of mitral regurgitation and reoperation. Compared with patients with simple disease, those undergoing repair of complex pathology were more likely to be younger and female (both P values < .0001) but with similar symptoms (P = .3). The most common repair technique was ring/band annuloplasty (3055/99% simple vs 3000/98% complex; P = .5), followed by leaflet resection (2802/90% simple vs 2249/74% complex; P < .0001). Among propensity-matched patients, recurrence of severe mitral regurgitation 10 years after repair was 6.2% for simple pathology versus 11% for complex pathology (P = .007), reoperation at 18 years was 6.3% for simple pathology versus 11% for complex pathology, and 20-year survival was 62% for simple pathology versus 61% for complex pathology (P = .6). Early surgical intervention has become more common in patients with degenerative MV disease, regardless of valve prolapse complexity or symptom status. Valve repair was associated with similarly low operative risk and time-related survival but less durability in complex disease. Lifelong annual echocardiographic surveillance after MV repair is recommended, particularly in patients with complex disease. Copyright © 2018 The American Association for Thoracic Surgery

  14. Myxomatous mitral valve disease in dogs - an update and perspectives

    Directory of Open Access Journals (Sweden)

    Aleksandra Domanjko Petrič

    2015-03-01

    Full Text Available Myxomatous mitral valve disease is a common cause of congestive heart failure in geriatric dogs. Many studies have been done in terms of epidemiology, pathology, associated neurohormonal changes in the disease progression, prognostic factors, and survival and treatment modalities. The presented paper presents a review of some of the studies in the mitral valve disease story.

  15. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    Science.gov (United States)

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  16. Inhibitory role of Notch1 in calcific aortic valve disease.

    Directory of Open Access Journals (Sweden)

    Asha Acharya

    Full Text Available Aortic valve calcification is the most common form of valvular heart disease, but the mechanisms of calcific aortic valve disease (CAVD are unknown. NOTCH1 mutations are associated with aortic valve malformations and adult-onset calcification in families with inherited disease. The Notch signaling pathway is critical for multiple cell differentiation processes, but its role in the development of CAVD is not well understood. The aim of this study was to investigate the molecular changes that occur with inhibition of Notch signaling in the aortic valve. Notch signaling pathway members are expressed in adult aortic valve cusps, and examination of diseased human aortic valves revealed decreased expression of NOTCH1 in areas of calcium deposition. To identify downstream mediators of Notch1, we examined gene expression changes that occur with chemical inhibition of Notch signaling in rat aortic valve interstitial cells (AVICs. We found significant downregulation of Sox9 along with several cartilage-specific genes that were direct targets of the transcription factor, Sox9. Loss of Sox9 expression has been published to be associated with aortic valve calcification. Utilizing an in vitro porcine aortic valve calcification model system, inhibition of Notch activity resulted in accelerated calcification while stimulation of Notch signaling attenuated the calcific process. Finally, the addition of Sox9 was able to prevent the calcification of porcine AVICs that occurs with Notch inhibition. In conclusion, loss of Notch signaling contributes to aortic valve calcification via a Sox9-dependent mechanism.

  17. Animal Models of Calcific Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Krista L. Sider

    2011-01-01

    Full Text Available Calcific aortic valve disease (CAVD, once thought to be a degenerative disease, is now recognized to be an active pathobiological process, with chronic inflammation emerging as a predominant, and possibly driving, factor. However, many details of the pathobiological mechanisms of CAVD remain to be described, and new approaches to treat CAVD need to be identified. Animal models are emerging as vital tools to this end, facilitated by the advent of new models and improved understanding of the utility of existing models. In this paper, we summarize and critically appraise current small and large animal models of CAVD, discuss the utility of animal models for priority CAVD research areas, and provide recommendations for future animal model studies of CAVD.

  18. Canine Degenerative Valve Disease: A Case Report

    Directory of Open Access Journals (Sweden)

    Carmenza Janneth Benavides Melo

    2014-07-01

    Full Text Available Degenerative valvular disease or endocardiosis is the most common cardiovascular pathology in dogs. It is characterized by regurgitation of blood into the atria with decreased cardiac output, leading to volume overload with eccentric hypertrophy and congestive heart failure. This report describes the clinical and autopsy findings of a dog, suggestive of valvular endocardiosis. The patient was admitted to the outpatient Veterinary Clinic “Carlos Martínez Hoyos” at the University of Nariño (Pasto, Colombia. His owner said the dog was sick for two months, with signs of respiratory disease, weight loss, and decay. Clinical examination showed very pale mucous membranes, inspiratory dyspnea, rale, split S2, grade 4 mid-systolic murmur of regurgitation, and abdominal dilatation with sign of positive shock wave. Necropsy evidenced plenty of translucent watery material in the abdominal, chest and pericardium cavity, severely enlarged and rounded heart with thickened atrioventricular valves, moderate reduction in liver size and signs of lobulation, severely diminished and pale kidneys with irregular surface showing the presence of multiple cystic areas in corticomedullary region. Samples were taken from these tissues and fixed in 10% buffered formalin to be processed for histopathological analysis at the Laboratory of Pathology at the University of Nariño, using hematoxylin and eosin stain. This way, degenerative valvular disease was diagnosed.

  19. Unicuspid aortic valve disease: a magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A.; Djavidani, B.; Poschenrieder, F.; Feuerbach, S.; Schmid, C.; Kobuch, R.

    2008-01-01

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 ± 4.7 cm 2 vs. 8.7 ± 2.3 cm 2 , p < 0.01 and 4.6 ± 0.7 cm vs. 3.6 ± 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 ± 0.6 cm vs. 2.3 ± 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 ± 0.5 cm vs. 2.6 ± 0.3 cm, p < 0.05). (orig.)

  20. Unicuspid aortic valve disease: a magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A. [Klinik und Poliklinik fuer Innere Medizin II, Universitaetsklinikum Regensburg (Germany); Djavidani, B.; Poschenrieder, F.; Feuerbach, S. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schmid, C.; Kobuch, R. [Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie, Universitaetsklinikum Regensburg (Germany)

    2008-11-15

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 {+-} 4.7 cm{sup 2} vs. 8.7 {+-} 2.3 cm{sup 2}, p < 0.01 and 4.6 {+-} 0.7 cm vs. 3.6 {+-} 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 {+-} 0.6 cm vs. 2.3 {+-} 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 {+-} 0.5 cm vs. 2.6 {+-} 0.3 cm, p < 0.05). (orig.)

  1. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  2. Surgery for rheumatic mitral valve disease in sub-saharan African ...

    African Journals Online (AJOL)

    However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, ...

  3. Heart rate, heart rate variability, and arrhythmias in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2012-01-01

    Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD).......Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD)....

  4. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  5. Congenital tricuspid valve disease and testicular agenesis: a case ...

    African Journals Online (AJOL)

    This is a report of a case of congenital tricuspid valve disease presenting with heart failure and pulmonary hypertension. Cardinal clinical features include breathlessness, easy fatigability since childhood, stunted growth, cyanosis, finger clubbing, a pansystolic murmur loudest at the left sternal edge in the fourth intercostal ...

  6. Fuzzy Pattern Classification Based Detection of Faulty Electronic Fuel Control (EFC Valves Used in Diesel Engines

    Directory of Open Access Journals (Sweden)

    Umut Tugsal

    2014-05-01

    Full Text Available In this paper, we develop mathematical models of a rotary Electronic Fuel Control (EFC valve used in a Diesel engine based on dynamic performance test data and system identification methodology in order to detect the faulty EFC valves. The model takes into account the dynamics of the electrical and mechanical portions of the EFC valves. A recursive least squares (RLS type system identification methodology has been utilized to determine the transfer functions of the different types of EFC valves that were investigated in this study. Both in frequency domain and time domain methods have been utilized for this purpose. Based on the characteristic patterns exhibited by the EFC valves, a fuzzy logic based pattern classification method was utilized to evaluate the residuals and identify faulty EFC valves from good ones. The developed methodology has been shown to provide robust diagnostics for a wide range of EFC valves.

  7. Durability of mitral valve repair for mitral regurgitation due to degenerative mitral valve disease.

    Science.gov (United States)

    David, Tirone E

    2015-09-01

    Degenerative diseases of the mitral valve (MV) are the most common cause of mitral regurgitation in the Western world and the most suitable pathology for MV repair. Several studies have shown excellent long-term durability of MV repair for degenerative diseases. The best follow-up results are obtained with isolated prolapse of the posterior leaflet, however even with isolated prolapse of the anterior leaflet or prolapse of both leaflets the results are gratifying, particularly in young patients. The freedom from reoperation on the MV at 15 years exceeds 90% for isolated prolapse of the posterior leaflet and it is around 70-85% for prolapse of the anterior leaflet or both leaflets. The degree of degenerative change in the MV also plays a role in durability of MV repair. Most studies have used freedom from reoperation to assess durability of the repair but some studies that examined valve function late after surgery suggest that recurrent mitral regurgitation is higher than estimated by freedom from reoperation. We can conclude that MV repair for degenerative mitral regurgitation is associated with low probability of reoperation for up to two decades after surgery. However, almost one-third of the patients develop recurrent moderate or severe mitral regurgitation suggesting that surgery does not arrest the degenerative process.

  8. Analysis of Mitral Valve Replacement Outcomes is Enhanced by Meaningful Clinical Use of Electronic Health Records

    Science.gov (United States)

    Chen, John C; Pfeffer, Thomas; Johnstone, Shelley; Chen, Yuexin; Kiley, Mary-Lou; Richter, Richard; Lee, Hon

    2013-01-01

    Objective: Cardiac surgical mortality has improved during the last decade despite the aging of the population. An integrated US health plan developed a heart valve registry to track outcomes and complications of heart valve operations. This database was used for longitudinal evaluation of mitral valve (MV) outcomes from 1999 to 2008 at four affiliated hospitals. Methods: We identified 3130 patients in the Apollo database who underwent 3180 initial MV procedures. Internal administrative and Social Security Administration databases were merged to determine survival rates. Electronic health records were searched to ascertain demographics, comorbidities, and postoperative complications. Cox regression was used to evaluate mean survival and identify risk factors. Results: The procedures included 1160 mechanical valve replacements, 1159 tissue valve replacements, and 861 annuloplasties. The mean age of patients undergoing these procedures was 58 ± 11 years, 69 ± 12 years, and 62 ± 12 years, respectively. Mean survival was 8.9 ± 0.1 years for mechanical valve replacement, 7.0 ± 0.1 years for tissue valve replacement, and 7.7 ± 0.1 years for annuloplasty. Early in the study, there was a preference for implanting mechanical MVs. Beginning in 2003, more patients received tissue valve replacements rather than mechanical valves. Over time, there was an increasing trend of annuloplasty. Cox regression analysis identified the following risk factors for increased ten-year mortality: tissue valve implantation; advanced age; female sex; nonelective, nonisolated procedure; diabetes; postoperative use of banked blood products; previous cardiovascular intervention; dialysis; and longer perfusion time. Hospital location, reoperation, preoperative anticoagulation, and cardiogenic shock were not statistically significant risk factors. Conclusions: When controlling for other risk factors, we observed a lower long-term survival rate for tissue valve replacement compared with

  9. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  10. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  11. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  12. Valve Repair Is Superior to Replacement in Most Patients With Coexisting Degenerative Mitral Valve and Coronary Artery Diseases.

    Science.gov (United States)

    Javadikasgari, Hoda; Gillinov, A Marc; Idrees, Jay J; Mihaljevic, Tomislav; Suri, Rakesh M; Raza, Sajjad; Houghtaling, Penny L; Svensson, Lars G; Navia, José L; Mick, Stephanie L; Desai, Milind Y; Sabik, Joseph F; Blackstone, Eugene H

    2017-06-01

    For mitral regurgitation (MR) from degenerative mitral disease in patients with coexisting coronary artery disease, the appropriate surgical strategy remains controversial. From 1985 to 2011, 1,071 adults (age 70 ± 9.3 years, 77% men) underwent combined coronary artery bypass grafting and either mitral valve repair (n = 872, 81%) or replacement (n=199, 19%) for degenerative MR. Propensity matching (177 patient pairs, 89% of possible matches) was used to compare early outcomes and time-related recurrence of MR after mitral valve repair, mitral valve reoperation, and mortality. Risk factors for death were identified with multivariable, multiphase hazard-function analysis. Patients undergoing valve replacement were older, with more valve calcification and a higher prevalence of preoperative atrial fibrillation and heart failure (all p < .0001). Among matched pairs, mitral replacement versus repair was associated with higher hospital mortality (5.0% vs 1.0%, p = .0001) and more postoperative renal failure (7.0% vs 3.2%, p = .01), reexplorations for bleeding (6.0% vs 3.1%, p = .05), and respiratory failure (14% vs 4.7%, p < .0001). Of matched patients undergoing repair, 18% had MR above 3+ by 5 years. Mitral valve durability was similar between matched groups, but survival at 15 years was 18% after replacement versus 52% after repair. Nomograms from the multivariable equation revealed that in 94% of cases, 10-year survival was calculated to be higher after repair than after replacement. In patients with coexisting degenerative mitral valve and coronary artery diseases, mitral valve repair is expected to confer a long-term survival advantage over replacement despite some recurrence of MR. When feasible, it is the procedure of choice for these patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    Science.gov (United States)

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  14. The changing course of aortic valve disease in Scotland: temporal trends in hospitalizations and mortality and prognostic importance of aortic stenosis.

    Science.gov (United States)

    Berry, Colin; Lloyd, Suzanne M; Wang, Yanzhong; Macdonald, Alyson; Ford, Ian

    2013-06-01

    To investigate the contemporary clinical course of aortic valve disease types. We performed a retrospective population-level epidemiological study of hospitalized care in Scotland from 1 January 1997 to 31 December 2005 using electronic case identification of hospital admissions and deaths. Time-to-event analyses were performed using Cox Proportional-Hazards models. A total of 19 733 adults with an index hospitalization and a final diagnosis of non-congenital aortic valve disease were identified. Aortic stenosis, aortic insufficiency, mixed aortic valve disease, or unspecified aortic valve disease occurred in 13 220 (67.0%), 2807 (14.2%), 699 (3.5%), and 3007 (15.2%), individuals, respectively. The majority of hospitalizations occurred in elderly persons aged 80 and older. In total, 9981 (50.6%) patients had died by 31 December 2006. When compared with aortic stenosis, the risk of death was less with aortic insufficiency [hazard ratio (95% confidence interval) 0.79 (0.74, 0.84)] and mixed aortic valve disease [0.83 (0.74, 0.93)]. Female gender, admission year, and hypertension were associated with lower mortality in patients with aortic stenosis. Patients with aortic stenosis had increased risk of death or heart failure (adjusted P valve replacement of whom 73.2% had aortic stenosis, 11.9% aortic valve disease (unspecified),10.0% aortic insufficiency, and 4.9% aortic stenosis with insufficiency. Patients with aortic stenosis with insufficiency had increased likelihood of aortic valve replacement [1.19 (1.02, 1.38)]. Age, female gender, and co-morbidity reduced the likelihood of aortic valve replacement. The incidence of aortic valve stenosis has substantially increased in Scotland in recent years. Aortic stenosis predicts morbidity and mortality when compared with other types of aortic valve disease.

  15. Developmental basis for filamin-A-associated myxomatous mitral valve disease

    Science.gov (United States)

    Sauls, Kimberly; de Vlaming, Annemarieke; Harris, Brett S.; Williams, Katherine; Wessels, Andy; Levine, Robert A.; Slaugenhaupt, Susan A.; Goodwin, Richard L.; Pavone, Luigi Michele; Merot, Jean; Schott, Jean-Jacques; Le Tourneau, Thierry; Dix, Thomas; Jesinkey, Sean; Feng, Yuanyi; Walsh, Christopher; Zhou, Bin; Baldwin, Scott; Markwald, Roger R.; Norris, Russell A.

    2012-01-01

    Aims We hypothesized that the structure and function of the mature valves is largely dependent upon how these tissues are built during development, and defects in how the valves are built can lead to the pathological progression of a disease phenotype. Thus, we sought to uncover potential developmental origins and mechanistic underpinnings causal to myxomatous mitral valve disease. We focus on how filamin-A, a cytoskeletal binding protein with strong links to human myxomatous valve disease, can function as a regulatory interface to control proper mitral valve development. Methods and results Filamin-A-deficient mice exhibit abnormally enlarged mitral valves during foetal life, which progresses to a myxomatous phenotype by 2 months of age. Through expression studies, in silico modelling, 3D morphometry, biochemical studies, and 3D matrix assays, we demonstrate that the inception of the valve disease occurs during foetal life and can be attributed, in part, to a deficiency of interstitial cells to efficiently organize the extracellular matrix (ECM). This ECM organization during foetal valve gestation is due, in part, to molecular interactions between filamin-A, serotonin, and the cross-linking enzyme, transglutaminase-2 (TG2). Pharmacological and genetic perturbations that inhibit serotonin-TG2-filamin-A interactions lead to impaired ECM remodelling and engender progression to a myxomatous valve phenotype. Conclusions These findings illustrate a molecular mechanism by which valve interstitial cells, through a serotonin, TG, and filamin-A pathway, regulate matrix organization during foetal valve development. Additionally, these data indicate that disrupting key regulatory interactions during valve development can set the stage for the generation of postnatal myxomatous valve disease. PMID:22843703

  16. Increased amount of atrial fibrosis in patients with atrial fibrillation secondary to mitral valve disease

    NARCIS (Netherlands)

    Geuzebroek, Guillaume S. C.; van Amersfoorth, Shirley C. M.; Hoogendijk, Mark G.; Kelder, Johannes C.; van Hemel, Norbert M.; de Bakker, Jacques M. T.; Coronel, Ruben

    2012-01-01

    Objective: Atrial fibrosis is related to atrial fibrillation but may differ in patients with mitral valve disease or lone atrial fibrillation. Therefore, we studied atrial fibrosis in patients with atrial fibrillation + mitral valve disease or with lone atrial fibrillation and compared it with

  17. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Melle, van Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie P. J.; Jongbloed, Monique R. M.; Post, Martijn C.; Sieswerda, Gertjan T.; in 't Veld, Anna Huis; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    Objectives To report the prevalence of aortic valve prosthesis patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis

  18. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; van Melle, Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C.; Sieswerda, Gertjan T.; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in

  19. Serotonin concentrations in platelets, plasma, mitral valve leaflet, and left ventricular myocardial tissue in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Cremer, Signe Emilie; Singletary, G.E.; Olsen, Lisbeth Høier

    2014-01-01

    HYPOTHESIS/OBJECTIVES: Altered serotonin (5-hydroxytryptamine, 5HT) signaling is postulated in development and progression of canine myxomatous mitral valve disease (MMVD). Little is known regarding platelet, plasma, valvular, or myocardial 5HT concentration ([5HT]) in affected dogs. We quantifie...

  20. Biphasic 201thallium scintgraphy after dipyridamole in mitral valve diseases

    International Nuclear Information System (INIS)

    Schmoliner, R.; Dudczak, R.; Kronik, G.; Moesslacher, H.; Kletter, K.; Frischauf, H.

    1980-01-01

    The results of biphasic 201 thallium scintigraphy after dipyridamole i.v. could neither prove nor exclude the presence of small focal lesions in the myocardium of 17 patients with mitral valve diseases. The frequent finding of a decrease in activity in the anterolateral myocardium is probably due to a relative increase in activity in the region of the inferior wall with superimposed areas of the papillary muscle and right ventricular myocardium. If the right ventricle is visualized in stress- or redistribution images, an increase in mean pulmonary artery pressure can be accepted. According to Cohen's criteria, a grade 2 or 3 virtually proves the existence of pulmonary hypertension, a grade 1 makes this finding rather probable. The possibility of pulmonary hypertension can not be excluded if the right ventricular myocardium is not visualized. (orig.) [de

  1. Coronary artery disease in patients undergoing valve replacement at a tertiary care cardiac centre

    International Nuclear Information System (INIS)

    Shaikh, A.H.; Hanif, B.; Hasan, K.; Hashmani, S.

    2011-01-01

    To determine the prevalence of coronary artery disease in patients undergoing valve surgery at a tertiary care cardiac centre. The medical records of 144 consecutive patients who underwent mitral, aortic or dual (mitral and aortic) valve replacement surgery at the Tabba Heart Institute between January 2006 to December 2008 were retrospectively reviewed. All patients underwent coronary angiogram. Significant coronary artery disease (CAD) is defined as coronary stenosis of > 50%. There were 74 (51.4%) males and 70 (48.6%) females in the study. The mean age was 51.64 +- 11 years. Of all, 73 (50.7%) underwent mitral valve replacement, 47 (32.6%) had aortic and 24 (16.7%) had dual valve replacement. Out of 144 patients, 99 (68.8%) had 50% stenosis. In patients who had undergone mitral valve replacement (MVR), significant coronary disease was found in 32.9%, whereas in patients who had undergone aortic valve replacement (AVR) and dual valve replacement (DVR) the prevalence of coronary disease was 31.9% and 25% respectively. Our results suggest that the overall prevalence of coronary artery disease in patients undergoing valve surgery in our population is comparable with prevalence reported in international data. (author)

  2. Management of mitral regurgitation in Marfan syndrome: Outcomes of valve repair versus replacement and comparison with myxomatous mitral valve disease.

    Science.gov (United States)

    Helder, Meghana R K; Schaff, Hartzell V; Dearani, Joseph A; Li, Zhuo; Stulak, John M; Suri, Rakesh M; Connolly, Heidi M

    2014-09-01

    The study objective was to evaluate patients with Marfan syndrome and mitral valve regurgitation undergoing valve repair or replacement and to compare them with patients undergoing repair for myxomatous mitral valve disease. We reviewed the medical records of consecutive patients with Marfan syndrome treated surgically between March 17, 1960, and September 12, 2011, for mitral regurgitation and performed a subanalysis of those with repairs compared with case-matched patients with myxomatous mitral valve disease who had repairs (March 14, 1995, to July 5, 2013). Of 61 consecutive patients, 40 underwent mitral repair and 21 underwent mitral replacement (mean [standard deviation] age, 40 [18] vs 31 [19] years; P = .09). Concomitant aortic surgery was performed to a similar extent (repair, 45% [18/40] vs replacement, 43% [9/21]; P = .87). Ten-year survival was significantly better in patients with Marfan syndrome with mitral repair than in those with replacement (80% vs 41%; P = .01). Mitral reintervention did not differ between mitral repair and replacement (cumulative risk of reoperation, 27% vs 15%; P = .64). In the matched cohort, 10-year survival after repair was similar for patients with Marfan syndrome and myxomatous mitral disease (84% vs 78%; P = .63), as was cumulative risk of reoperation (17% vs 12%; P = .61). Patients with Marfan syndrome and mitral regurgitation have better survival with repair than with replacement. Survival and risk of reoperation for patients with Marfan syndrome were similar to those for patients with myxomatous mitral disease. These results support the use of mitral valve repair in patients with Marfan syndrome and moderate or more mitral regurgitation, including those having composite replacement of the aortic root. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  3. Toll-Like Receptors, Inflammation, and Calcific Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Carmen García-Rodríguez

    2018-03-01

    Full Text Available Inflammation, the primary response of innate immunity, is essential to initiate the calcification process underlying calcific aortic valve disease (CAVD, the most prevalent valvulopathy in Western countries. The pathogenesis of CAVD is multifactorial and includes inflammation, hemodynamic factors, fibrosis, and active calcification. In the development of CAVD, both innate and adaptive immune responses are activated, and accumulating evidences show the central role of inflammation in the initiation and propagation phases of the disease, being the function of Toll-like receptors (TLR particularly relevant. These receptors act as sentinels of the innate immune system by recognizing pattern molecules from both pathogens and host-derived molecules released after tissue damage. TLR mediate inflammation via NF-κB routes within and beyond the immune system, and play a crucial role in the control of infection and the maintenance of tissue homeostasis. This review outlines the current notions about the association between TLR signaling and the ensuing development of inflammation and fibrocalcific remodeling in the pathogenesis of CAVD. Recent data provide new insights into the inflammatory and osteogenic responses underlying the disease and further support the hypothesis that inflammation plays a mechanistic role in the initiation and progression of CAVD. These findings make TLR signaling a potential target for therapeutic intervention in CAVD.

  4. Comparative Transcriptomic Profiling and Gene Expression for Myxomatous Mitral Valve Disease in the Dog and Human

    Directory of Open Access Journals (Sweden)

    Greg R. Markby

    2017-07-01

    Full Text Available Myxomatous mitral valve disease is the single most important mitral valve disease in both dogs and humans. In the case of the dog it is ubiquitous, such that all aged dogs will have some evidence of the disease, and for humans it is known as Barlow’s disease and affects up to 3% of the population, with an expected increase in prevalence as the population ages. Disease in the two species show many similarities and while both have the classic myxomatous degeneration only in humans is there extensive fibrosis. This dual pathology of the human disease markedly affects the valve transcriptome and the difference between the dog and human is dominated by changes in genes associated with fibrosis. This review will briefly examine the comparative valve pathology and then, in more detail, the transcriptomic profiling and gene expression reported so far for both species.

  5. Acupuncture in patients with valvular heart disease and prosthetic valves.

    Science.gov (United States)

    Stellon, Anthony

    2003-09-01

    Endocarditis has been reported in patients with valvular heart disease who have undergone acupuncture treatment, although most have been associated with the use of semi-permanent needles. This has led reviewers to suggest that acupuncture may not only be contraindicated in such patients but that prophylactic antibiotics should be given. This study investigated the use of acupuncture treatment in patients with proven valvular heart disease and observed whether endocarditis developed in such patients. All patients in a single-handed GP practice with proven valvular heart disease, including those with prosthetic valves, were identified over a ten-year period. Those who had undergone acupuncture treatment underwent a clinical examination and diagnostic tests, which focused on the signs, symptoms and laboratory criteria for the diagnosis of endocarditis and included a transthoracic echocardiogram. Autopsy findings were reviewed in any patient who died. Based on these clinical and laboratory data, using the modified Duke's criteria for the diagnosis of endocarditis, patients were identified as having definite or possible endocarditis, or the diagnosis was rejected. All patients underwent brief acupuncture with no skin disinfectant and no prophylactic antibiotics were given. Semi-permanent needles were avoided. Thirty-six patients with valvular heart disease underwent a total of 479 acupuncture treatments over a ten-year period. The median number of treatments was 9 (range 1-72), with a follow-up after treatment of 5.75 years (range 0.5-10 years). Definite endocarditis was not found in any patient, but two patients had possible endocarditis, eventually discounted by both negative blood cultures and echocardiography. In conclusion, brief acupuncture was safe in this small cohort of valvular heart disease patients and no case of endocarditis was detected over a ten-year period.

  6. A low-cost bioprosthetic semilunar valve for research, disease modelling and surgical training applications.

    Science.gov (United States)

    Rosa, Benoit; Machaidze, Zurab; Shin, Borami; Manjila, Sunil; Brown, David W; Baird, Christopher W; Mayer, John E; Dupont, Pierre E

    2017-11-01

    This paper provides detailed instructions for constructing low-cost bioprosthetic semilunar valves for animal research and clinical training. This work fills an important gap between existing simulator training valves and clinical valves by providing fully functioning designs that can be employed in ex vivo and in vivo experiments and can also be modified to model valvular disease. Valves are constructed in 4 steps consisting of creating a metal frame, covering it with fabric and attaching a suture ring and leaflets. Computer-aided design files are provided for making the frame from wire or by metal 3D printing. The covering fabric and suturing ring are made from materials readily available in a surgical lab, while the leaflets are made from pericardium. The entire fabrication process is described in figures and in a video. To demonstrate disease modelling, design modifications are described for producing paravalvular leaks, and these valves were evaluated in porcine ex vivo (n = 3) and in vivo (n = 6) experiments. Porcine ex vivo and acute in vivo experiments demonstrate that the valves can replicate the performance of clinical valves for research and training purposes. Surgical implantation is similar, and echocardiograms are comparable to clinical valves. Furthermore, valve leaflet function was satisfactory during acute in vivo tests with little central regurgitation, while the paravalvular leak modifications consistently produced leaks in the desired locations. The detailed design procedure presented here, which includes a tutorial video and computer-aided design files, should be of substantial benefit to researchers developing valve disease models and to clinicians developing realistic valve training systems. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Calcific Aortic Valve Disease Is Associated with Layer-Specific Alterations in Collagen Architecture.

    Directory of Open Access Journals (Sweden)

    Heather N Hutson

    Full Text Available Disorganization of the valve extracellular matrix (ECM is a hallmark of calcific aortic valve disease (CAVD. However, while microarchitectural features of the ECM can strongly influence the biological and mechanical behavior of tissues, little is known about the ECM microarchitecture in CAVD. In this work, we apply advanced imaging techniques to quantify spatially heterogeneous changes in collagen microarchitecture in CAVD. Human aortic valves were obtained from individuals between 50 and 75 years old with no evidence of valvular disease (healthy and individuals who underwent valve replacement surgery due to severe stenosis (diseased. Second Harmonic Generation microscopy and subsequent image quantification revealed layer-specific changes in fiber characteristics in healthy and diseased valves. Specifically, the majority of collagen fiber changes in CAVD were found to occur in the spongiosa, where collagen fiber number increased by over 2-fold, and fiber width and density also significantly increased. Relatively few fibrillar changes occurred in the fibrosa in CAVD, where fibers became significantly shorter, but did not otherwise change in terms of number, width, density, or alignment. Immunohistochemical staining for lysyl oxidase showed localized increased expression in the diseased fibrosa. These findings reveal a more complex picture of valvular collagen enrichment and arrangement in CAVD than has previously been described using traditional analysis methods. Changes in fiber architecture may play a role in regulating the pathobiological events and mechanical properties of valves during CAVD. Additionally, characterization of the ECM microarchitecture can inform the design of fibrous scaffolds for heart valve tissue engineering.

  8. Vasovagal tonus index in dog with myxomatous mitral valve disease

    Directory of Open Access Journals (Sweden)

    Bruna C. Brüler

    Full Text Available ABSTRACT: The vasovagal tonus index (VVTI is a useful and assessable index, obtained from standard ECG recordings, that is used to estimate heart rate variability (HRV, and may provide valuable information regarding the likelihood of progression into congestive heart failure (CHF. In this paperwork, we investigated how the vasovagal tonus index (VVTI behaves in dogs with naturally-occurring myxomatous mitral valve disease (MMVD Electrocardiographic (ECG recordings and echocardiographic data of 120 patients diagnosed with MMVD were reviewed. The VVTI was calculated from twenty consecutive RR intervals for each dog enrolled in the study. Lower VVTI values were found in MMVD patients in American College of Veterinary Internal Medicine (ACVIM stage C compared with stages B1 and B2. Values were also lower in patients with severe cardiac remodeling. When a cut-off value of 6.66 is used, VVTI was able to discriminate MMVD patients in stage C from B1 and B2 dogs with a sensitivity of 70 per cent and a specificity of 77 per cent. MMVD dogs in which VVTI is lower than 6.66 are 30% more likely to develop congestive heart failure (CHF.

  9. Cardiac implantable electronic device and associated risk of infective endocarditis in patients undergoing aortic valve replacement

    DEFF Research Database (Denmark)

    Østergaard, Lauge; Valeur, Nana; Bundgaard, Henning

    2017-01-01

    Aims: Patients undergoing aortic valve replacement (AVR) are at increased risk of infective endocarditis (IE) as are patients with a cardiac implantable electronic device (CIED). However, few data exist on the IE risk after AVR surgery in patients with a CIED. Methods and results: Using the Danish...

  10. Surgery for rheumatic mitral valve disease in sub-saharan African countries: why valve repair is still the best surgical option.

    Science.gov (United States)

    Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie

    2016-01-01

    Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.

  11. Prosthetic valves in adult patients with congenital heart disease : Rationale and design of the Dutch PROSTAVA study

    NARCIS (Netherlands)

    Freling, H. G.; van Slooten, Y. J.; van Melle, J. P.; Mulder, B. J. M.; van Dijk, A. P. J.; Hillege, H. L.; Post, M. C.; Sieswerda, G. Tj; Jongbloed, M. R. M.; Willems, T. P.; Pieper, P. G.

    2012-01-01

    Data on long-term complications in adult patients with congenital heart disease (ACHD) and a prosthetic valve are scarce. Moreover, the influence of prosthetic valves on quality of life (QoL) and functional outcome in ACHD patients with prosthetic valves has not been studied. The primary objective

  12. Ekhokardiografi Endokardiosis Penyakit Katup Mitral Jantung Anjing (ECHOCARDIOGRAPHY OF ENDOCARDIOSIS MITRAL VALVE HEART DISEASE IN DOGS

    Directory of Open Access Journals (Sweden)

    Deni Noviana

    2013-08-01

    Full Text Available Endocardiosis is a disease commonly found in Pomeranian dog characterized by progressive myxomatousdegeneration of the atrio-ventricular valves especially in the mitral valve. The purpose of this study was todefine the diagnose and severeity of this disease on the Pomeranian by using brightness mode, motion mode,dan color flow Doppler echocardiography technique. Echocardiography was performed on 8 Pomeranianconsisting of 6 males and 2 females with age range of 2-14 years. Brightness mode echocardiography wasused to see the echotexture of endocardium, mitral valve, and the valve movement. The results showedendocardium thickening, along with chronic fibrosis and nodular thickening of the anterior and posteriormitral valve leaflet. Three out of seven cases showed prolapsed of the mitral valve. Motion modeechocardiography was performed in order to measure left ventricle internal dimension, myocardium thickness,fractional shortening, left atrial and aortic dimension. The results showed myocardium thickening, alongwith left atrial enlargement. Color flow Doppler echocardiography was used to confirm the mitral valveregurgitation. Three of seven cases showed the presence of regurgitation signed by turbulence color of theprolapsed mitral valve. Based on the degree of severity, scoring system used in this study, endocardiosis canbe divided into three types that are mild, moderate and severe.

  13. Clinical Implication of Aortic Wall Biopsy in Aortic Valve Disease with Bicuspid Valve Pathology

    Directory of Open Access Journals (Sweden)

    Yong Han Kim

    2016-12-01

    Full Text Available Background: Although unique aortic pathology related to bicuspid aortic valve (BAV has been previously reported, clinical implications of BAV to aortopathy risk have yet to be investigated. We looked for potential differences in matrix protein expressions in the aortic wall in BAV patients. Methods: Aorta specimens were obtained from 31 patients: BAV group (n=27, tricuspid aortic valve (TAV group (n=4. The BAV group was categorized into three subgroups: left coronary sinus-right coronary sinus (R+L group; n=13, 42%, right coronary sinus-non-coronary sinus (R+N group; n=8, 26%, and anteroposterior (AP group; n=6, 19%. We analyzed the expression of endothelial nitric oxide synthase (eNOS, matrix metalloproteinase (MMP-9, and tissue inhibitor of matrix metalloproteinase (TIMP-2. Results: Based on the mean value of the control group, BAV group showed decreased expression of eNOS in 72.7% of patients, increased MMP-9 in 82.3%, and decreased TIMP in 79.2%. There was a higher tendency for aortopathy in the BAV group: eNOS (BAV:TAV= 53%±7%:57%±11%, MMP-9 (BAV:TAV=48%±10%:38%±1%. The AP group showed lower expression of eNOS than the fusion (R+L, R+N group did; 48%±5% vs. 55%±7% (p=0.081. Conclusion: Not all patients with BAV had expression of aortopathy; however, for patients who had a suspicious form of bicuspid valve, aortic wall biopsy could be valuable to signify the presence of aortopathy.

  14. A DECISION SUPPORT SYSTEM FOR THE DIAGNOSIS OF HEART VALVE DISEASES

    OpenAIRE

    Türkoğlu, İbrahim; Arslan, Ahmet; İlkay, Erdoğan

    2018-01-01

    In this pa per, a decision s up port system is presented for interpretation of the Doppler signals of the heart valve diseases based on the pattern recognition. This paper especially deals with the feature extraction from measured Doppler signal waveforms at the heart valve using the Doppler Ultrasound. Wavelet transforms and power spectrum estimate by Yule-Walker AR method are used to feature extract from the Doppler signals on the time­frequency domain. Wavelet entropy method is applied to ...

  15. Rheumatic Heart Disease and Myxomatous Degeneration: Differences and Similarities of Valve Damage Resulting from Autoimmune Reactions and Matrix Disorganization.

    Science.gov (United States)

    Martins, Carlo de Oliveira; Demarchi, Lea; Ferreira, Frederico Moraes; Pomerantzeff, Pablo Maria Alberto; Brandao, Carlos; Sampaio, Roney Orismar; Spina, Guilherme Sobreira; Kalil, Jorge; Cunha-Neto, Edecio; Guilherme, Luiza

    2017-01-01

    Autoimmune inflammatory reactions leading to rheumatic fever (RF) and rheumatic heart disease (RHD) result from untreated Streptococcus pyogenes throat infections in individuals who exhibit genetic susceptibility. Immune effector mechanisms have been described that lead to heart tissue damage culminating in mitral and aortic valve dysfunctions. In myxomatous valve degeneration (MXD), the mitral valve is also damaged due to non-inflammatory mechanisms. Both diseases are characterized by structural valve disarray and a previous proteomic analysis of them has disclosed a distinct profile of matrix/structural proteins differentially expressed. Given their relevance in organizing valve tissue, we quantitatively evaluated the expression of vimentin, collagen VI, lumican, and vitronectin as well as performed immunohistochemical analysis of their distribution in valve tissue lesions of patients in both diseases. We identified abundant expression of two isoforms of vimentin (45 kDa, 42 kDa) with reduced expression of the full-size protein (54 kDa) in RHD valves. We also found increased vitronectin expression, reduced collagen VI expression and similar lumican expression between RHD and MXD valves. Immunohistochemical analysis indicated disrupted patterns of these proteins in myxomatous degeneration valves and disorganized distribution in rheumatic heart disease valves that correlated with clinical manifestations such as valve regurgitation or stenosis. Confocal microscopy analysis revealed a diverse pattern of distribution of collagen VI and lumican into RHD and MXD valves. Altogether, these results demonstrated distinct patterns of altered valve expression and tissue distribution/organization of structural/matrix proteins that play important pathophysiological roles in both valve diseases.

  16. Long-term tricuspid valve prosthesis-related complications in patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Freling, Hendrik G.; van Melle, Joost P.; Mulder, Barbara J. M.; Jongbloed, Monique R. M.; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    2014-01-01

    In patients with acquired valvar disease, morbidity and mortality rates after tricuspid valve replacement (TVR) are high. However, in adult patients with congenital heart disease, though data concerning outcome after TVR are scarce, even poorer results are suggested in patients with Ebstein anomaly.

  17. Long-term tricuspid valve prosthesis-related complications in patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Freling, Hendrik G.; van Melle, Joost P.; Mulder, Barbara J. M.; Jongbloed, Monique R. M.; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    OBJECTIVES: In patients with acquired valvar disease, morbidity and mortality rates after tricuspid valve replacement (TVR) are high. However, in adult patients with congenital heart disease, though data concerning outcome after TVR are scarce, even poorer results are suggested in patients with

  18. Imaging of Mitral Valve Prolapse: What Can We Learn from Imaging about the Mechanism of the Disease?

    Directory of Open Access Journals (Sweden)

    Ronen Durst

    2015-07-01

    Full Text Available Mitral valve prolapse (MVP is the most common mitral valve disorder affecting 2%–3% of the general population. Two histological forms for the disease exist: Myxomatous degeneration and fibroelastic disease. Pathological evidence suggests the disease is not confined solely to the valve tissue, and accumulation of proteoglycans and fibrotic tissue can be seen in the adjacent myocardium of MVP patients. MVP is diagnosed by demonstrating valve tissue passing the annular line into the left atrium during systole. In this review we will discuss the advantages and limitations of various imaging modalities in their MVP diagnosis ability as well as the potential for demonstrating extra associated valvular pathologies.

  19. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair

    Directory of Open Access Journals (Sweden)

    Mustafa Zakkar

    2018-03-01

    Full Text Available Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  20. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.

    Science.gov (United States)

    Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.

  1. Rheumatic heart disease- a study of surgically excised cardiac valves and biopsies

    International Nuclear Information System (INIS)

    Khalil Ullah; Badsha, S.; Khan, A.; Kiani, M.R.; Ahmed, S.A.

    2002-01-01

    Objective: To examine the prevalence, age, sex and topographical distribution of the rheumatic heart diseases and its morphology. Design: A cross sectional descriptive study. Place and Duration of Study: Pathology Department, Army Medical College, Rawalpindi between 1981-1990. Patients and Methods: Five hundred and twenty six surgically excised cardiac valves and biopsies were studied in the laboratory in the light of clinical data. Results: Carditis constituted 87.4 % of the cardiac valvular disease with 23.5% active and 71% healed rheumatic lesions. About 5.5% had morphological appearances consistent with RHD. The lesions affected mitral valves (37.0%), aortic valve (22.1%), mitral and aortic valves together (21.0%) and atrial appendages (19.0%). Presentation was mostly as mitral stenosis either isolated (49.2% ) or combined (31.0%), aortic stenosis (11.7% ) and aortic incompetence with regurgitation (7.3%). Conclusion: Rheumatic carditis constitutes a significant proportion of cardiac valvular disease and affects comparatively younger age, with slight male preponderance and primarily affects mitral valve. (author)

  2. Association of altered collagen content and lysyl oxidase expression in degenerative mitral valve disease.

    Science.gov (United States)

    Purushothaman, K-Raman; Purushothaman, Meerarani; Turnbull, Irene C; Adams, David H; Anyanwu, Anelechi; Krishnan, Prakash; Kini, Annapoorna; Sharma, Samin K; O'Connor, William N; Moreno, Pedro R

    Collagen cross-linking is mediated by lysyl oxidase (LOX) enzyme in the extracellular matrix (ECM) of mitral valve leaflets. Alterations in collagen content and LOX protein expression in the ECM of degenerative mitral valve may enhance leaflet expansion and disease severity. Twenty posterior degenerative mitral valve leaflets from patients with severe mitral regurgitation were obtained at surgery. Five normal posterior mitral valve leaflets procured during autopsy served as controls. Valvular interstitial cells (VICs) density was quantified by immunohistochemistry, collagen Types I and III by picro-sirius red staining and immunohistochemistry, and proteoglycans by alcian blue staining. Protein expression of LOX and its mediator TGFβ1 were quantified by immunofluorescence and gene expression by PCR. VIC density was increased, structural Type I collagen density was reduced, while reparative Type III collagen and proteoglycan densities were increased (PDegenerative Mitral Valve Disease may be secondary to alterations in LOX protein expression, contributing to disorganization of ECM and disease severity. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The value of MRI in the diagnosis of heart valve diseases

    International Nuclear Information System (INIS)

    Zhao Shihua; Lu Minjie; Zhang Yan; Jiang Shiliang; Liu Yuqing; Zhang Puhong

    2006-01-01

    Objective: To assess the diagnostic value of the magnetic resonance imaging (MRI) for heart valve disease qualitatively and quantitatively. Methods: From 18th Sep, 2004 to 30th Jun, 2005, 56 consecutive patients underwent MR scanning with multiple sequences, including two-dimensional dark and bright sequences, K-space segmented TrueFISP and FLASH cine sequences, as well as velocity-encoded cine MR(VEC-MR). Morphologic and functional parameters were applied to assess the disease qualitatively and quantitatively. For quantitative analysis, Doppler echocardiography was compared to evaluate the reliability of VEC-MR in assessing the severity of aortic valve disease. Correlations coefficient was analyzed by a statistic software (SPSS 13.0), P sq =0.951, P=0.01 for AS and R=0.965, R sq =0.932, P<0.01 for AI). Conclusion: Heart valve diseases can be qualitatively and quantitatively evaluated by MR multiple sequences, especially in aortic valve disease. (authors)

  4. Interaction of renal failure and dyslipidaemia in the development of calcific aortic valve disease in rats.

    Science.gov (United States)

    Gillis, Kris; Roosens, Bram; Bala, Gezim; Remory, Isabel; Hernot, Sophie; Delvenne, Philippe; Mestrez, Fabienne; Droogmans, Steven; Cosyns, Bernard

    2017-10-01

    Calcific aortic valve disease (CAVD) is currently the most common heart valve disease worldwide and is known to be an active process. Both renal failure and dyslipidaemia are considered to be promoting factors for the development of valvular calcifications. The aim of this study is to prospectively evaluate the respective contribution and interaction of renal failure and dyslipidaemia on CAVD in a rat model, using echocardiography and compared with histology. Sixty-eight male Wistar rats were prospectively divided in eight groups, each fed a different diet to induce renal failure alone and combined with hyperlipidaemia or hypercholesterolemia. CAVD was detected and quantified by calibrated integrated backscatter of ultrasound (cIB) and compared with the histological calcium score. The study follow-up was 20 weeks. At the end of the study, the cIB value and the calcium score of the aortic valve were significantly increased in the group with isolated renal failure but not with dyslipidaemia. The combination of renal failure with high cholesterol or high-fat diet did not significantly increase calcifications further. Renal failure alone does induce aortic valve calcifications in a rat model of CAVD, whereas dyslipidaemia alone does not. The combination of renal failure with dyslipidaemia does not increase calcification further. These findings suggest that a combination of atherosclerotic and calcifying factors is not required to induce aortic valve calcifications in this model.

  5. Von Willebrand Factor as a Novel Player in Valvular Heart Disease: From Bench to Valve Replacement.

    Science.gov (United States)

    Gragnano, Felice; Crisci, Mario; Bigazzi, Maurizio Cappelli; Bianchi, Renatomaria; Sperlongano, Simona; Natale, Francesco; Fimiani, Fabio; Concilio, Claudia; Cesaro, Arturo; Pariggiano, Ivana; Diana, Vincenzo; Limongelli, Giuseppe; Cirillo, Plinio; Russo, Mariagiovanna; Golia, Enrica; Calabrò, Paolo

    2018-02-01

    von Willebrand Factor (vWF) is a well-known mediator of hemostasis and vascular inflammation. Its dynamic modulation in the bloodstream, according to hemodynamic conditions, makes it an appealing biomarker in patients with valvular heart disease (VHD). Recent studies highlight the close connection between vWF and VHD, with possible implications in the pathogenesis of VHD, promoting valve aging and calcification or favoring the development of infective endocarditis. Moreover, vWF has been recently proposed as a new diagnostic and prognostic tool in patients with valve stenosis or regurgitation, showing a strict correlation with severity of valve disease, outcome, and bleeding (Heyde syndrome). A novel role for vWF is also emerging in patients undergoing percutaneous or surgical valve repair/replacement to select and stratify patients, evaluate periprocedural bleeding risk, and detect procedural complications. We also report our single-center experience, suggesting, for the first time, possible clinical implications for vWF in percutaneous mitral valve repair (MitraClip). This review summarizes recent advances in the role of vWF in VHD with an updated overview going from bench to operating room.

  6. Cardiac Hemodynamics in the Pathogenesis of Congenital Heart Disease and Aortic Valve Calcification

    Science.gov (United States)

    Nigam, Vishal

    2011-11-01

    An improved understanding of the roles of hemodynamic forces play in cardiac development and the pathogenesis of cardiac disease will have significant scientific and clinical impact. I will focus on the role of fluid dynamics in congenital heart disease and aortic valve calcification. Congenital heart defects are the most common form of birth defect. Aortic valve calcification/stenosis is the third leading cause of adult heart disease and the most common form of acquired valvular disease in developed countries. Given the high incidence of these diseases and their associated morbidity and mortality, the potential translational impact of an improved understanding of cardiac hemodynamic forces is very large. Division of Pediatric Cardiology, Rady Children's Hospital, San Diego

  7. Outcome of double vs. single valve replacement for rheumatic heart disease

    International Nuclear Information System (INIS)

    Akhtar, R.P.; Abid, A.R.

    2010-01-01

    To compare the follow-up results of double valve replacement (DVR) i.e. mitral valve replacement (MVR) and aortic valve replacement (AVR) vs. isolated MVR or AVR for rheumatic heart disease. Study Design: An interventional qausi-experimental study. Prospective follow-up of 493 patients with mechanical heart valves was carried out using clinical assessment, international normalized ratio and echocardiography. Patients were divided into three groups: group I having MVR, group II having AVR and group III having DVR. Survival, time and causes of mortality, and frequency of valve thrombosis, haemorrhage and cerebrovascular haemorrhage was noted in the three groups and described as proportions. Actuarial survival was analyzed by Kaplan-Meier method. There were 493 with 287 (58.3%) in group I, 87 (17.6%) in group II and 119 (24.1%) in group III. Total follow-up was 2429.2 patient (pt)-years. Of 77 (15.6%) deaths, 19 (3.8%) were in-hospital and 58 (11.8%) were late. In-hospital mortality was highest 4 (4.6%) in group II followed by 5 (4.2%) group III and 10 (3.5%) group I. Late deaths were 39 (13.4%) in group I, 9 (10.2%) in group II and 10 (8.3%) in group III. The total actuarial survival was 84.4% with survival of 83%, 85.1%, 87.4% in groups I, II and III respectively. On follow-up valve thrombosis occurred in 12 (0.49%/pt-years) patients; 9 (0.67%/pt-years) group I, 1 (0.22%/pt-years) in group II and 2 (0.31%/pt-years) in group III. Severe haemorrhage occurred in 19 (0.78%/pt-years); 14 in (1.04%/pt-years) in group I, 3 (0.66%/pt-years) group II and 2 (0.31%/pt-years) in group III. Cerebrovascular accidents occurred in 34 (1.3%/pt-years); 26 (1.95%/pt-years) in group I and 4 in groups II (0.89%/pt-years) and III (0.62%/pt-years) each. In patients with rheumatic heart disease having combined mitral and aortic valve disease DVR should be performed whenever indicated as it has similar in-hospital mortality and better late survival as compared to isolated aortic or mitral

  8. Effects of right ventricular morphology and function on outcomes of patients with degenerative mitral valve disease.

    Science.gov (United States)

    Ye, Ying; Desai, Ravi; Vargas Abello, Lina M; Rajeswaran, Jeevanantham; Klein, Allan L; Blackstone, Eugene H; Pettersson, Gösta B

    2014-11-01

    The study objective was to investigate whether, in patients undergoing surgery for degenerative mitral valve disease, associated right ventricular remodeling and dysfunction are stronger determinants of preoperative organ dysfunction and prognosis than functional tricuspid regurgitation. From January 2001 to January 2011, 4197 patients underwent primary mitral valve surgery for degenerative valve disease at Cleveland Clinic. Using a quasi-experimental enriched study design, 781 patients were randomly selected within each grade of functional tricuspid regurgitation. Renal function was assessed by glomerular filtration rate and blood urea nitrogen, and hepatic function was assessed by Model for End-stage Liver Disease (MELD) score. Preoperative and postoperative right ventricular morphology and function were measured de novo on stored echocardiographic images. To assess survival, 3471 patient-years of follow-up data were available for analysis. Several preoperative right ventricular variables, but not functional tricuspid regurgitation grade (P>.05), were associated with preoperative renal and hepatic dysfunction, but neither was associated with early mortality (.2), was among the risk factors for later mortality. Postoperative unadjusted right ventricular function, but not functional tricuspid regurgitation grade (P≥.2), was associated with both early (P=.04) and later (P=.01) mortality, but in multivariable analysis appeared to be a surrogate for worse preoperative condition. Together with patient comorbidities and operative factors, right ventricular morphology and function are associated more strongly with preoperative organ dysfunction and prognosis than is functional tricuspid regurgitation severity in patients undergoing surgery for degenerative mitral valve disease. Our previous study showed that tricuspid valve repair remains the most effective treatment to improve right ventricular function. Copyright © 2014 The American Association for Thoracic Surgery

  9. Echocardiographic Evaluation of Hemodynamic Changes in Left-Sided Heart Valves in Pregnant Women With Valvular Heart Disease.

    Science.gov (United States)

    Samiei, Niloufar; Amirsardari, Mandana; Rezaei, Yousef; Parsaee, Mozhgan; Kashfi, Fahimeh; Hantoosh Zadeh, Sedigheh; Beikmohamadi, Somayeh; Fouladi, Masoumeh; Hosseini, Saeid; Peighambari, Mohammad Mehdi; Mohebbi, Ahmad

    2016-10-01

    Physiologic changes during pregnancy can deteriorate or improve patients' hemodynamic status in the setting of valvular heart disease. There are sparse data regarding the effect of pregnancy on valve hemodynamics in normal pregnant women with known valvular heart disease. In a prospective study from July 2014 to January 2016, a total of 52 normal pregnant women who had mitral stenosis, aortic stenosis, or a history of mitral valve or aortic valve replacements were assessed. All patients underwent echocardiographic examinations and hemodynamic parameters were measured for both the mitral valve and aortic valve at first, second, and third trimesters. The parameters included mean gradient, peak gradient, mean gradient/heart rate, peak gradient/heart rate, pressure halftime, dimensionless velocity index, and valve area. Although most hemodynamic parameters (i.e., mean gradient, peak gradient, mean gradient/heart rate, and peak gradient/heart rate) increased approximately 50% from first to second trimester and first to third trimester (p 0.05). The ratio of changes between trimesters for valve area and dimensionless velocity index were comparable. No clinical decompensations were observed except for 3 and 7 cases of deterioration to functional class II at second and third trimesters, respectively. In conclusion, during a full-term and uncomplicated pregnancy, mitral and aortic valve gradients increase without significant changes in valve area that are more marked between the second and first trimester than between the third and second trimester. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Pars plana Ahmed valve and vitrectomy in patients with glaucoma associated with posterior segment disease.

    Science.gov (United States)

    Wallsh, Josh O; Gallemore, Ron P; Taban, Mehran; Hu, Charles; Sharareh, Behnam

    2013-01-01

    To assess the safety and efficacy of a modified technique for pars plana placement of the Ahmed valve in combination with pars plana vitrectomy in the treatment of glaucoma associated with posterior segment disease. Thirty-nine eyes with glaucoma associated with posterior segment disease underwent pars plana vitrectomy combined with Ahmed valve placement. All valves were placed in the pars plana using a modified technique, without the pars plana clip, and using a scleral patch graft. The 24 eyes diagnosed with neovascular glaucoma had an improvement in intraocular pressure from 37.6 mmHg to 13.8 mmHg and best-corrected visual acuity from 2.13 logarithm of minimum angle of resolution to 1.40 logarithm of minimum angle of resolution. Fifteen eyes diagnosed with steroid-induced glaucoma had an improvement in intraocular pressure from 27.9 mmHg to 14.1 mmHg and best-corrected visual acuity from 1.38 logarithm of minimum angle of resolution to 1.13 logarithm of minimum angle of resolution. Complications included four cases of cystic bleb formation and one case of choroidal detachment and explantation for hypotony. Ahmed valve placement through the pars plana during vitrectomy is an effective option for managing complex cases of glaucoma without the use of the pars plana clip.

  11. Cellular Changes during Renal Failure-Induced Inflammatory Aortic Valve Disease.

    Directory of Open Access Journals (Sweden)

    Mony Shuvy

    Full Text Available Aortic valve calcification (AVC secondary to renal failure (RF is an inflammation-regulated process, but its pathogenesis remains unknown. We sought to assess the cellular processes that are involved in the early phases of aortic valve disease using a unique animal model of RF-associated AVC.Aortic valves were obtained from rats that were fed a uremia-inducing diet exclusively for 2, 3, 4, 5, and 6 weeks as well as from controls. Pathological examination of the valves included histological characterization, von Kossa staining, and antigen expression analyses.After 2 weeks, we noted a significant increase in urea and creatinine levels, reflecting RF. RF parameters exacerbated until the Week 5 and plateaued. Whereas no histological changes or calcification was observed in the valves of any study group, macrophage accumulation became apparent as early as 2 weeks after the diet was started and rose after 3 weeks. By western blot, osteoblast markers were expressed after 2 weeks on the diet and decreased after 6 weeks. Collagen 3 was up-regulated after 3 weeks, plateauing at 4 weeks, whereas collagen 1 levels peaked at 2 and 4 weeks. Fibronectin levels increased gradually until Week 5 and decreased at 6 weeks. We observed early activation of the ERK pathway, whereas other pathways remained unchanged.We concluded that RF induces dramatic changes at the cellular level, including macrophage accumulation, activation of cell signaling pathway and extracellular matrix modification. These changes precede valve calcification and may increase propensity for calcification, and have to be investigated further.

  12. Heart Rate Variability in Cavalier King Charles Spaniels with Different Degree of Myxomatous Mitral Valve Disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2010-01-01

    Sciences, University of Copenhagen, Frederiksberg, Denmark, 2Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden; and 3Novo Nordic A/S, Maaloev, Denmark. Introduction: Modulation of heart rate by the autonomic nervous system can indirectly be measured by heart rate...... variability (HRV). Reduced HRV is seen in dogs with heart failure secondary to myxomatous mitral valve disease (MMVD). However, HRV is suggested to increase with disease progression in dogs with early stages of MMVD. Comparable results are found in people with primary mitral valve prolapse, a disease...... resembling canine MMVD. Aim: To associate progression of MMVD in dogs with time and frequency domain HRV, analysed from 24-hour electrocardiography. Materials and Methods: Eighty-one Cavalier King Charles Spaniels (CKCS) were examined by echocardiography and 24-hour electrocardiography. CKCS were divided...

  13. The changing course of aortic valve disease in Scotland:temporal trends in hospitalizations and mortality and prognostic importance of aortic stenosis

    OpenAIRE

    Berry, Colin; Lloyd, Suzanne M; Wang, Yanzhong; Macdonald, Alyson; Ford, Ian

    2013-01-01

    Aims: To investigate the contemporary clinical course of aortic valve disease types.Methods and results: We performed a retrospective population-level epidemiological study of hospitalized care in Scotland from 1 January 1997 to 31 December 2005 using electronic case identification of hospital admissions and deaths. Time-to-event analyses were performed using Cox Proportional-Hazards models. A total of 19 733 adults with an index hospitalization and a final diagnosis of non-congenital aortic ...

  14. Spin-resolved electron waiting times in a quantum-dot spin valve

    Science.gov (United States)

    Tang, Gaomin; Xu, Fuming; Mi, Shuo; Wang, Jian

    2018-04-01

    We study the electronic waiting-time distributions (WTDs) in a noninteracting quantum-dot spin valve by varying spin polarization and the noncollinear angle between the magnetizations of the leads using the scattering matrix approach. Since the quantum-dot spin valve involves two channels (spin up and down) in both the incoming and outgoing channels, we study three different kinds of WTDs, which are two-channel WTD, spin-resolved single-channel WTD, and cross-channel WTD. We analyze the behaviors of WTDs in short times, correlated with the current behaviors for different spin polarizations and noncollinear angles. Cross-channel WTD reflects the correlation between two spin channels and can be used to characterize the spin-transfer torque process. We study the influence of the earlier detection on the subsequent detection from the perspective of cross-channel WTD, and define the influence degree quantity as the cumulative absolute difference between cross-channel WTDs and first-passage time distributions to quantitatively characterize the spin-flip process. We observe that influence degree versus spin-transfer torque for different noncollinear angles as well as different polarizations collapse into a single curve showing universal behaviors. This demonstrates that cross-channel WTDs can be a pathway to characterize spin correlation in spintronics system.

  15. Characterization of the calcification of cardiac valve bioprostheses by environmental scanning electron microscopy and vibrational spectroscopy.

    Science.gov (United States)

    Delogne, Christophe; Lawford, Patricia V; Habesch, Steven M; Carolan, Vikki A

    2007-10-01

    Bioprosthetic heart valve tissue and associated calcification were studied in their natural state, using environmental scanning electron microscopy (ESEM). Energy dispersive X-ray micro-analysis, X-ray diffraction, Fourier-transform infrared and Raman spectroscopy were used to characterize the various calcific deposits observed with ESEM. The major elements present in calcified valves were also analyzed by inductively coupled plasma-optical emission spectroscopy. To better understand the precursor formation of the calcific deposits, results from the elemental analyses were statistically correlated. ESEM revealed the presence of four broad types of calcium phosphate crystal morphology. In addition, two main patterns of organization of calcific deposits were observed associated with the collagen fibres. Energy dispersive X-ray micro-analysis identified the crystals observed by ESEM as salts containing mainly calcium and phosphate with ratios from 1.340 (possibly octacalcium phosphate, which has a Ca/P ratio of 1.336) to 2.045 (possibly hydroxyapatite with incorporation of carbonate and metal ion contaminants, such as silicon and magnesium, in the crystal lattice). Raman and fourier-transform infrared spectroscopy also identified the presence of carbonate and the analyses showed spectral features very similar to a crystalline hydroxyapatite spectrum, also refuting the presence of precursor phases such as beta-tricalcium phosphate, octacalcium phosphate and dicalcium phosphate dihydrate. The results of this study raised the possibility of the presence of precursor phases associated with the early stages of calcification.

  16. Assessment of right ventricular afterload in mitral valve diseases with radionuclide angiography

    International Nuclear Information System (INIS)

    Shimizu, Mitsuharu; Nakagawa, Tomio; Kohno, Yoshihiro; Kuroda, Masahiro; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao; Senoh, Yoshimasa; Teramoto, Shigeru

    1991-01-01

    Right ventricular function at rest and during exercise was studied in 33 patients with mitral valve disease by equilibrium gated radionuclide angiography using 99m Tc in vivo labeled red blood cells. Radionuclide measurements of right ventricular ejection fraction (RVEF) were correlated with mean pulmonary arterial pressure (mPAP). RVEF decreased significantly with exercise. There was no significant correlation between RVEF at rest and mPAP. However, mPAP showed significant negative correlation with RVEF during exercise and with the changes of RVEF from rest to exercise. It is concluded that RVEF during exercise in mitral valve disease is affected by right ventricular afterload, and the measurements of RVEF at rest and during exercise by equilibrium gated radionuclide angiography is useful to assess right ventricular afterload. (author)

  17. Mitral valve surgery - open

    Science.gov (United States)

    ... Taking warfarin (Coumadin) References Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Mitral Valve Prolapse Read more A. ...

  18. Double Valve Replacement (Mitral and Aortic for Rheumatic Heart Disease: A 20-year experience with 300 patients.

    Directory of Open Access Journals (Sweden)

    Prashant Mishra

    2016-09-01

    Full Text Available Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic in patients of rheumatic heart disease. Materials and Methods: Between 1988 and 2008, 300 patients of rheumatic heart disease underwent double (Mitral and Aortic valve replacement with Starr Edwards valve or St Jude mechanical valve prosthesis were implanted. These patients were studied retrospectively for preoperative data and postoperative outcome including causes of early and late deaths and the data was analyzed statistically. Results: The 30-day hospital death rate was 11.3% andlate death occurred in 11.6%. Anticoagulant regimen was followed to maintain the target pro-thrombin time at 1.5 times the control value. The actuarial survival (exclusive of hospital mortality was 92.4%, 84.6%, and 84.4%, per year at 5, 10, and 20 years, respectively Conclusions: In view of the acknowledged advantageof superior durability, increased thromboresistance in our patient population, and its cost effectiveness the Starr-Edwards ball valve or St. Jude valve is the mechanical prosthesis of choice for advanced combined valvular disease. The low-intensity anticoagulant regimen has offered suffcient protection against thromboembolism as well as hemorrhage.

  19. [Cox/maze III procedure combined with mitral valve replacement in treatment of rheumatic mitral valve disease with atrial fibrilation].

    Science.gov (United States)

    Chen, Rukun; Wang, Yongqing; Chen, Yongbing; Chen, Suocheng

    2002-06-25

    To compare the curative effect of Cox/maze III procedure combined with mitral replacement and that of mitral valve replacement (MVR). Fifty-six patients suffering from rheumatic heart disease with atrial fibrillation (AF) were treated by Cox/maze III procedure combined with MVR (maze group). Another 56 age, sex, and heart function-matched patients with the same diagnosis underwent MVR alone during the same period. Warfarin was administered after operation in both groups. Comparison of operative complication and curative effects was made. The aortic cross-clamp time and cardio pulmonary bypass time (CPB) were longer in maze group than in MVT group (75 +/- 22 min vs 41 +/- 11 min, P Atrial contractility was restored in all patients with sinus rhythm. One year after operation, 98.18% patients' cardiac function changed to grade and 1.82% changed to grade II. In MVR group AF disappeared after operation temporarily for 24 hours in 7 patients and re-appeared, and AF disappeared in one patients for 2 years so far. One year after operation, the cardiac function of 94.6% patients in MVR group changed to grade I, of 3.6% patients to grade II, and of 1.8% patients to grade III. No serious hemorrhage relate d to anticoagulant therapy happened. One patient in MVR group suffered from hemiplegia due to cerebral embolism. The late mortality was 1.8% on maze group amd 3.6% in MVR group. Cox/maze III procedure combined with NVR is safe and effective in treating rheumatic heart disease with AF.

  20. Capacity modulation of an inverter-driven multi-air conditioner using electronic expansion valves

    International Nuclear Information System (INIS)

    Choi, J.M.; Kim, Y.C.

    2003-01-01

    An inverter-driven multi-air conditioner provides the benefits of comfort, energy conservation and easy maintenance. Recently, the multi-air conditioner has been employed in small and medium-sized buildings. However, the performance data and control algorithm for multi-air conditioners are limited in literature due to complicated system parameters and operating conditions. In the present study, the performance of an inverter-driven multi-air conditioner having two indoor units with electronic expansion valves (EEV) was measured by varying indoor loads, EEV opening, and compressor speed. Based on the experimental results, the operating characteristics and capacity modulation of the inverter-driven multi-air conditioner are discussed. As a result, it is suggested that the superheats for both indoor units have to be maintained around 4 o C by utilizing the EEVs in this system, and consequently, the compressor speed needs to be adjusted to provide optimum cooling capacity for each indoor unit

  1. Autoimmune Disease with Cardiac Valves Involvement: Libman-Sacks Endocarditis.

    Science.gov (United States)

    Ginanjar, Eka; Yulianto, Yulianto

    2017-04-01

    This case study aim to evaluate the response of steroid treatment for autoimmune endocarditis. Valvular heart disease is relatively rising in both congenital and acquired cases, but the autoimmune endocarditis remains rare. In this case, a 34 year old woman with clinical manifestation resembling systemic lupus erythematosus (SLE) is diagnosed with Libman-sacks Endocarditis. After six months of steroid treatment, her clinical manifestations and heart structure improved.

  2. Contemporary results of aortic valve repair for congenital disease: lessons for management and staged strategy.

    Science.gov (United States)

    Vergnat, Mathieu; Asfour, Boulos; Arenz, Claudia; Suchowerskyj, Philipp; Bierbach, Benjamin; Schindler, Ehrenfried; Schneider, Martin; Hraska, Victor

    2017-09-01

    Any aortic valve (AoV) operation in children (repair, Ross or mechanical replacement) is a palliation and reinterventions are frequent. AoV repair is a temporary solution primarily aimed at allowing the patient to grow to an age when more definitive solutions are available. We retrospectively analysed AoV repair effectiveness across the whole age spectrum of children, excluding neonates and AoV disease secondary to congenital heart disease. From 2003 to 2015, 193 consecutive patients were included. The mean age was 9.2 ± 6.9 years (22% disease. The procedures performed were commissurotomy shaving (n = 74; 38%), leaflet replacement (n = 78; 40%), leaflet extension (n = 21; 11%) and neocommissure creation (n = 21; 11%). Post-repair geometry was tricuspid in 137 (71%) patients. The 10-year survival rate was 97.1%. Freedom from reoperation and replacement at 7 years was, respectively, 57% (95% confidence interval, 47-66) and 68% (95% confidence interval, 59-76). In multivariate analysis, balloon dilatation before 6 months, the absence of a developed commissure, a non-tricuspid post-repair geometry and cross-clamp duration were predictors for reoperation and replacement. After a mean follow-up period of 5.1 ± 3.0 years, 145 (75%) patients had a preserved native valve, with undisturbed valve function (peak gradient <40 mmHg, regurgitation ≤mild) in 113 (58%). Aortic valve repair in children is safe and effective in delaying the timing for more definitive solution. Surgical strategy should be individualized according to the age of the patient. Avoidance of early balloon dilatation and aiming for a tricuspid post-repair arrangement may improve outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  3. Does concomitant tricuspid annuloplasty increase perioperative mortality and morbidity when correcting left-sided valve disease?

    Science.gov (United States)

    Zhu, Tie-Yuan; Wang, Jian-Gang; Meng, Xu

    2015-01-01

    A best evidence topic in adult valvular surgery was written according to a structured protocol. The question addressed was 'Does concomitant tricuspid annuloplasty increase the perioperative mortality and morbidity when correcting left-sided valve disease?' A total of 561 papers were found using the reported search, of which 12 presented the best evidence to answer the clinical question. The authors, country, journal, date of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Among these 12 papers, there were nine retrospective studies, two cohort studies and one randomized controlled trial (RCT). Overall, additional tricuspid valve (TV) repair takes more time during operations, particularly with a ring annuloplasty method. The mean aortic cross-clamping times were 57-83 min without associated tricuspid repair and 62-100 min with, and cardiopulmonary bypass times without and with repair were 82-124 and 90-174 min, respectively. A study of 624 patients who had undergone isolated mitral valve (MV) surgery and MV surgery plus TV repair showed more female and atrial fibrillation patients in the tricuspid valve plasty (TVP) group, but no increase in the 30-day mortality was found. One RCT, presenting similar patient baseline characteristics, also found no difference in the hospital mortality rates between the TVP group and the non-TVP group. Another 10 studies also demonstrated no statistically significant differences in perioperative mortality. In a cohort study of 311 patients undergoing MV repair with or without tricuspid annuloplasty, postoperative complications, such as bleeding, stroke, pacemaker, haemofiltration and myocardial infarction, all showed no statistically significant differences in the two groups. One study retrospectively analysed a large number of patients undergoing either isolated left-sided valve surgery or a concomitant TV repair, and there were no statistically significant differences

  4. Predictive value of natriuretic peptides in dogs with mitral valve disease

    DEFF Research Database (Denmark)

    Tarnow, Inge; Olsen, Lisbeth Høier; Kvart, Clarence

    2009-01-01

    Natriuretic peptides are useful in diagnosing heart failure in dogs. However, their usefulness in detecting early stages of myxomatous mitral valve disease (MMVD) has been debated. This study evaluated N-terminal (NT) fragment pro-atrial natriuretic peptide (NT-proANP) and NT-pro-brain natriuretic...... peptide (NT-proBNP) in 39 Cavalier King Charles Spaniels (CKCS) with pre-clinical mitral valve regurgitation (MR), sixteen dogs with clinical signs of heart failure (HF) and thirteen healthy control dogs. Twenty seven CKCS and ten control dogs were re-examined 4 years after the initial examination...... and the status of the dogs 5 years after the initial examination was determined by telephone calls to the owner. All dogs were evaluated by clinical examination and echocardiography. CKCS with severe MR had higher NT-proANP and NT-proBNP compared to controls and CKCS with less severe MR. Dogs with clinical signs...

  5. Comprehensive microRNA profiling reveals potential augmentation of the IL1 pathway in rheumatic heart valve disease.

    Science.gov (United States)

    Lu, Qiyu; Sun, Yi; Duan, Yuyin; Li, Bin; Xia, Jianming; Yu, Songhua; Zhang, Guimin

    2018-03-16

    Valvular heart disease is a leading cause of cardiovascular mortality, especially in China. More than a half of valvular heart diseases are caused by acute rheumatic fever. microRNA is involved in many physiological and pathological processes. However, the miRNA profile of the rheumatic valvular heart disease is unknown. This research is to discuss microRNAs and their target gene pathways involved in rheumatic heart valve disease. Serum miRNA from one healthy individual and four rheumatic heart disease patients were sequenced. Specific differentially expressed miRNAs were quantified by Q-PCR in 40 patients, with 20 low-to-moderate rheumatic mitral valve stenosis patients and 20 severe mitral valve stenosis patients. The target relationship between certain miRNA and predicted target genes were analysis by Luciferase reporter assay. The IL-1β and IL1R1 expression levels were analyzed by immunohistochemistry and western blot in the mitral valve from surgery of mitral valve replacement. The results showed that 13 and 91 miRNAs were commonly upregulated or downregulated in all four patients. Nine miRNAs, 1 upregulated and 8 downregulated, that had a similar fold change in all 4 patients were selected for quantitative PCR verification. The results showed similar results from miRNA sequencing. Within these 9 tested miRNAs, hsa-miR-205-3p and hsa-miR-3909 showed a low degree of dispersion between the members of each group. Hsa miR-205-3p and hsa-miR-3909 were predicted to target the 3'UTR of IL-1β and IL1R1 respectively. This was verified by luciferase reporter assays. Immunohistochemistry and Western blot results showed that the mitral valve from rheumatic valve heart disease showed higher levels of IL- 1β and IL1R1 expression compared with congenital heart valve disease. This suggested a difference between rheumatic heart valve disease and other types of heart valve diseases, with more inflammatory responses in the former. In the present study, by next generation

  6. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease.

    Science.gov (United States)

    van Slooten, Ymkje J; van Melle, Joost P; Freling, Hendrik G; Bouma, Berto J; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C; Sieswerda, Gertjan T; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A; Pieper, Petronella G

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in life. However, the prevalence and clinical consequences of aortic PPM in ACHD are presently unknown. From the national Dutch Congenital Corvitia (CONCOR) registry, we identified 207 ACHD with an aortic valve prosthesis for this cross-sectional cohort study. Severe PPM was defined as an indexed effective orifice area ≤0.65 cm2/m2 and moderate PPM as an indexed orifice area ≤0.85 cm2/m2 measured using echocardiography. Exercise capacity was reported as percentage of predicted exercise capacity (PPEC). Of the 207 patients, 68% was male, 71% had a mechanical prosthesis and mean age at inclusion was 43.9 years ±11.4. The prevalence of PPM was 42%, comprising 23% severe PPM and 19% moderate PPM. Prevalence of PPM was higher in patients with mechanical prostheses (pHeart Association (NYHA) class remained stable in most patients. PPM showed no significant effect on death or hospitalisation during follow-up (p=0.218). In this study we report a high prevalence (42%) of PPM in ACHD with an aortic valve prosthesis and an independent association of PPM with diminished exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Oxidized Phospholipids and Risk of Calcific Aortic Valve Disease

    DEFF Research Database (Denmark)

    Kamstrup, Pia R.; Hung, Ming Yow; Witztum, Joseph L.

    2017-01-01

    -control study was performed within the Copenhagen General Population Study (n=87 980), including 725 CAVD cases (1977-2013) and 1413 controls free of cardiovascular disease. OxPL carried by apoB (apolipoprotein B-100; OxPL-apoB) or apolipoprotein(a) (OxPL-apo(a)) containing lipoproteins, lipoprotein(a) levels......, LPA kringle IV type 2 repeat, and rs10455872 genetic variants were measured. OxPL-apoB and OxPL-apo(a) levels correlated with lipoprotein(a) levels among cases (r=0.75 and r=0.95; both Plevels associated with risk of CAVD with odds.......001). Corresponding odds ratios for OxPL-apo(a) were 1.2 (95% CI, 1.0-1.5), 1.2(95% CI, 0.9-1.6), 2.1(95% CI, 1.4-3.1), and 2.9(95% CI, 1.9-4.5; trend, Pa) levels and explained 34%, 46%, and 39...

  8. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    Science.gov (United States)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  9. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    Science.gov (United States)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  10. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    Science.gov (United States)

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  11. Surgical RF ablation of atrial fibrillation in patients undergoing mitral valve repair for Barlow disease.

    Science.gov (United States)

    Rostagno, Carlo; Droandi, G; Gelsomino, S; Carone, E; Gensini, G F; Stefàno, P L

    2013-01-01

    At present, limited experience exists on the treatment of atrial fibrillation (AF) in patients undergoing mitral valve repair (MVR) for Barlow disease. The aim of this investigation was to prospectively evaluate the radiofrequency ablation of AF in patients undergoing MVR for severe regurgitation due to Barlow disease. From January 1, 2007 to December 31, 2010, out of 85 consecutive patients with Barlow disease, 27 with AF underwent RF ablation associated with MVR. They were examined every 4 months in the first year after surgery and thereafter twice yearly. At follow-up, AF was observed in 4/25 (16.0%). NYHA (New York Heart Association) functional class improved significantly, with no patients in class III or IV (before surgery, 81.5% had been). Otherwise, among 58 patients in sinus rhythm, 6 (11%) developed AF during follow-up. No clinical or echocardiographic predictive factor was found in this subgroup. Results from our investigation suggest that radiofrequency ablation of AF in patients with Barlow disease undergoing MVR for severe regurgitation is effective and should be considered in every patient with Barlow disease and AF undergoing valve surgical repair. Copyright © 2013 S. Karger AG, Basel.

  12. Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases

    Science.gov (United States)

    Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.

    2017-01-01

    Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects

  13. Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.

    Science.gov (United States)

    Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L

    2017-06-15

    Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were

  14. Surgical Treatment of Atrial Fibrillation in Patients with Rheumatic Valve Disease

    Directory of Open Access Journals (Sweden)

    Ernesto Koehler Chavez

    Full Text Available Abstract Objective: To assess heart rhythm and predictive factors associated with sinus rhythm after one year in patients with rheumatic valve disease undergoing concomitant surgical treatment of atrial fibrillation. Operative mortality, survival and occurrence of stroke after one year were also evaluated. Methods: Retrospective longitudinal observational study of 103 patients undergoing rheumatic mitral valve surgery and ablation of atrial fibrillation using uni- or bipolar radiofrequency between January 2013 and December 2014. Age, gender, functional class (NYHA, type of atrial fibrillation, EuroSCORE, duration of atrial fibrillation, stroke, left atrial size, left ventricular ejection fraction, cardiopulmonary bypass time, myocardial ischemia time and type of radiofrequency were investigated. Results: After one year, 66.3% of patients were in sinus rhythm. Sinus rhythm at hospital discharge, lower left atrial size in the preoperative period and bipolar radiofrequency were associated with a greater chance of sinus rhythm after one year. Operative mortality was 7.7%. Survival rate after one year was 92.3% and occurrence of stroke was 1%. Conclusion: Atrial fibrillation ablation surgery with surgical approach of rheumatic mitral valve resulted in 63.1% patients in sinus rhythm after one year. Discharge from hospital in sinus rhythm was a predictor of maintenance of this rhythm. Increased left atrium and use of unipolar radiofrequency were associated with lower chance of sinus rhythm. Operative mortality rate of 7.7% and survival and stroke-free survival contribute to excellent care results for this approach.

  15. Nanoscale magnetic characterization of tunneling magnetoresistance spin valve head by electron holography.

    Science.gov (United States)

    Park, Hyun Soon; Hirata, Kei; Yanagisawa, Keiichi; Ishida, Yoichi; Matsuda, Tsuyoshi; Shindo, Daisuke; Tonomura, Akira

    2012-12-07

    Nanostructured magnetic materials play an important role in increasing miniaturized devices. For the studies of their magnetic properties and behaviors, nanoscale imaging of magnetic field is indispensible. Here, using electron holography, the magnetization distribution of a TMR spin valve head of commercial design is investigated without and with a magnetic field applied. Characterized is the magnetic flux distribution in complex hetero-nanostructures by averaging the phase images and separating their component magnetic vectors and electric potentials. The magnetic flux densities of the NiFe (shield and 5 nm-free layers) and the CoPt (20 nm-bias layer) are estimated to be 1.0 T and 0.9 T, respectively. The changes in the magnetization distribution of the shield, bias, and free layers are visualized in situ for an applied field of 14 kOe. This study demonstrates the promise of electron holography for characterizing the magnetic properties of hetero-interfaces, nanostructures, and catalysts. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Angiotensin-converting enzyme activity in Cavalier King Charles Spaniels with an ACE gene polymorphism and myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Meurs, Kathryn M.; Olsen, Lisbeth H.; Reimann, Maria J.

    2018-01-01

    a canine ACE gene polymorphism associated with a decrease in angiotensin-converting enzyme (ACE) activity. The aim of this study was to evaluate for the prevalence of the ACE polymorphism in CKCS with mitral valve disease and to determine whether the presence of the polymorphism is associated......Objectives Myxomatous mitral valve disease (MMVD) is the most common heart disease in the dog. It is particularly common in the Cavalier King Charles Spaniel (CKCS) breed and affected dogs are frequently managed with angiotensin-converting enzyme inhibitors (ACE-I). We have previously identified...... with alterations in ACE activity at different stages of cardiac disease. Methods Seventy-three dogs with a diagnosis of mitral valve disease were evaluated and a blood sample was drawn for ACE polymorphism genotyping and ACE activity measurement. Results Forty-three dogs were homozygous for the ACE polymorphism...

  17. Association of Aortic Valve Sclerosis with Previous Coronary Artery Disease and Risk Factors

    Directory of Open Access Journals (Sweden)

    Filipe Carvalho Marmelo

    2014-11-01

    Full Text Available Background: Aortic valve sclerosis (AVS is characterized by increased thickness, calcification and stiffness of the aortic leaflets without fusion of the commissures. Several studies show an association between AVS and presence of coronary artery disease. Objective: The aim of this study is to investigate the association between presence of AVS with occurrence of previous coronary artery disease and classical risk factors. Methods: The sample was composed of 2,493 individuals who underwent transthoracic echocardiography between August 2011 and December 2012. The mean age of the cohort was 67.5 ± 15.9 years, and 50.7% were female. Results: The most frequent clinical indication for Doppler echocardiography was the presence of stroke (28.8%, and the most common risk factor was hypertension (60.8%. The most prevalent pathological findings on Doppler echocardiography were mitral valve sclerosis (37.1% and AVS (36.7%. There was a statistically significant association between AVS with hypertension (p < 0.001, myocardial infarction (p = 0.007, diabetes (p = 0.006 and compromised left ventricular systolic function (p < 0.001. Conclusion: Patients with AVS have higher prevalences of hypertension, stroke, hypercholesterolemia, myocardial infarction, diabetes and compromised left ventricular systolic function when compared with patients without AVS. We conclude that there is an association between presence of AVS with previous coronary artery disease and classical risk factors.

  18. Mitral valve reconstruction in Barlow disease: long-term echographic results and implications for surgical management.

    Science.gov (United States)

    Jouan, Jérôme; Berrebi, Alain; Chauvaud, Sylvain; Menasché, Philippe; Carpentier, Alain; Fabiani, Jean-Noël

    2012-04-01

    Owing to the complexity of the underlying lesions, Barlow disease remains a challenge for surgeons performing mitral valve repair. We aimed to assess whether our most recent results involving several surgeons were comparable with those of a previous experience in which mitral valve repair was performed by a more limited group of surgeons. From September 2000 to January 2007, 200 patients with Barlow disease (135 men and 65 women; mean age, 56 ± 13 years) were referred to our institution for surgical treatment of their mitral regurgitation. We retrospectively analysed the mitral lesions characteristics, the surgical techniques used, and clinical outcomes. Follow-up echocardiograms were biannually reviewed. Lesions comprised annular dilatation, excess tissue, and leaflet prolapse in all cases. The most frequent prolapsed segments were P2 (88.5%; n = 177) and A2 (55.5%; n = 111). Annular calcifications and restrictive valvular motion were associated in 20% (n = 40). Repair was feasible in 94.7% (n = 179/189) of non-redo interventions. Immediate postoperative echocardiography showed residual mitral regurgitation greater than 1+ in 6 cases; these patients were all reoperated on within the next months. Operative mortality was 1.5% (n = 3). Mean follow-up was 77.5 ± 25.6 months. At 8 years postoperatively, overall survival was 88.6% ± 3.1%, freedom from reintervention was 95.3% ± 1.7%, and freedom from late recurrent moderate mitral regurgitation (>2+) was 90.2% ± 3.1% Provided that the fundamental principles of mitral valve reconstruction are respected, the surgical techniques are highly reproducible with good long-term results, similar to those published during the pioneering phase of this surgery. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  19. Contribution of Auger electron spectroscopy to study of mechanism of adhesive wear of valves

    International Nuclear Information System (INIS)

    Smrkovsky, E.; Koutnik, M.; Potmesilova, A.

    1987-01-01

    Briefly characterized are hypotheses describing the process of intensive adhesive wear (jamming) of materials on functional friction surfaces of valves. Two types of alloys were studied, 1Cr18Ni8Mo5Mn5Si5Nb and NiCrSiB. Auger electron spectroscopy was used in the study of the chemical composition of surface layers. The following conclusions can be made from the results of the adhesive wear measurement and the Auger spectroscopy measurement: There are oxide layers on the surfaces of the specimens which, however, can only to a certain extent affect the process of adhesive wear. Adhesive wear resistance tests using low hardness specimens show that in spite of the existence of oxide layers, friction pairs showing low surface hardness also feature low adhesive wear resistance. Following heat treatment, the surface oxide layers have practically the same chemical composition as the specimens without heat treatment. However, there adhesive wear resistance is significantly higher. (Z.M.). 3 tabs., 7 refs

  20. Microwave spectroscopy and electronic transport properties of ferromagnetic Josephson junctions and superconducting spin-valves

    Energy Technology Data Exchange (ETDEWEB)

    Thalmann, Marcel; Rudolf, Marcel; Pietsch, Torsten [Zukunftskolleg and Department of Physics, University of Konstanz, Universitaetsstrasse 10, 78464 Konstanz (Germany)

    2016-07-01

    Hybrid superconducting nanostructures recently attracted tremendous interest, due to their great potential in dissipation-less spin-electronics with unprecedented switching rates. The practical realisation of such devices, however, requires a complete understanding of the transfer and dynamics of spin- and charge currents between superconducting (S) and ferromagnetic (F) circuit elements, as well as the coupling between spin- and charge degrees of freedom in these systems. We investigate novel transport phenomena in superconductor-ferromagnet hybrid nanostructures under non-equilibrium conditions. Microwave spectroscopy is used to elucidate fundamental questions related to the complex interplay of competing order parameters and the question of relaxation mechanisms of non-equilibrium distributions with respect to spin, charge and energy. Recent experiments on two complimentary device structures are discussed: (I) in diffusive S/F/S Josephson junctions with non-sinusoidal current-phase relationship and (II) local and non-local transport measurements and microwave spectroscopy in F/S/F lateral spin-valves.

  1. Refrigerant flow through electronic expansion valve: Experiment and neural network modeling

    International Nuclear Information System (INIS)

    Cao, Xiang; Li, Ze-Yu; Shao, Liang-Liang; Zhang, Chun-Lu

    2016-01-01

    Highlights: • Experimental data from different sources were used in comparison of EEV models. • Artificial neural network in EEV modeling is superior to literature correlations. • Artificial neural network with 4-4-1 structure and S function is recommended. • Artificial neural network is flexible for EEV mass flow rate and opening prediction. - Abstract: Electronic expansion valve (EEV) plays a crucial role in controlling refrigerant mass flow rate of refrigeration or heat pump systems for energy savings. However, complexities in two-phase throttling process and geometry make accurate modeling of EEV flow characteristics more difficult. This paper developed an artificial neural network (ANN) model using refrigerant inlet and outlet pressures, inlet subcooling, EEV opening as ANN inputs, refrigerant mass flow rate as ANN output. Both linear and nonlinear transfer functions in hidden layer were used and compared to each other. Experimental data from multiple sources including in-house experiments of one EEV with R410A were used for ANN training and test. In addition, literature correlations were compared with ANN as well. Results showed that the ANN model with nonlinear transfer function worked well in all cases and it is much accurate than the literature correlations. In all cases, nonlinear ANN predicted refrigerant mass flow rates within ±0.4% average relative deviation (A.D.) and 2.7% standard deviation (S.D.), meanwhile it predicted the EEV opening at 0.1% A.D. and 2.1% S.D.

  2. Transcriptomic profiling of peripheral blood nucleated cells in dogs with and without clinical signs of chronic mitral valve disease

    Directory of Open Access Journals (Sweden)

    Garncarz Magdalena

    2014-03-01

    Full Text Available The aim of the study was to demonstrate differences in the gene expression of signalling pathways between healthy dogs and dogs with chronic mitral valve disease in different heart failure groups. Blood samples were collected from 49 dogs of various breeds between 1.4 and 15.2 years of age. Isolated RNA samples were analysed for quality and integrity and the gene expression profile was determined. The study demonstrated that nucleated cells from peripheral blood can be used to assess the status of heart failure in dogs. Furthermore, significant differences in the expression of the genes were noticed between healthy dogs and dogs with clinical signs of chronic mitral valve disease. This is a preliminary non-invasive study showing the feasibility of genetic testing from peripheral blood nucleated cells, which at the same time has made it possible to set the future directions of genetic studies in clinical cases of canine chronic mitral valve disease.

  3. Triple leaflet perforation due to endocarditis in aortic valve complicated by pneumonia and exacerbation of chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Elton Soydan

    2015-09-01

    Full Text Available Valve perforation complicating infective endocarditis has been for decades a bad sign leading to severe valve destruction, intractable heart failure and even death if surgical therapy is not administered in time. Here we present a 57 years old male patient inadvertently diagnosed with pneumonia and chronic obstructive pulmonary disease exacerbation in another hospital. After 20 days of broad spectrum antibiotics and bronchodilator therapy no improvement was achieved. During examination a severe aortic regurgitation was recognized. Immediately after, patient was transferred to our hospital for aortic valve surgery evaluation. Transthorasic echocardiography (TTE showed a severe aortic regurgitation and vegetation like echogenicity over the noncoronary leaflet. An aortic valve replacement surgical therapy was decided. During the aortic valve excision underneath the vegetations, multiple small perforations in all the three leaflets were noticed. The destructed valve was excised and a mechanical aortic prosthesis (St Jude No: 23, MN, USA was successfully replaced. After 14 days of treatment patient was healthily discharged.

  4. Pulmonary abnormalities in mitral valve disease. Comparison between pulmonary wedge pressure, regional pulmonary blood flow and chest films

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, L H; Andersen, Jr, P E [Odense Univ. (Denmark)

    1978-01-01

    Chest films, right sided heart catheterization, and measurement of the regional lung perfusion, using /sup 133/Xe, were carried out 31 times on patients with mitral valve disease. A relationship was found between the radiologic evaluation in 3 grades, and the values of pulmonary wedge pressure and the apical and basal perfusion. Changes in flow distribution as reflected in altered appearance of the vessels and the presence of interstitial edema were found to be the most sensitive factors in the evaluation of pulmonary wedge pressure. Chest radiography was thus found suitable for the evaluation of pulmonary wedge pressure in mitral valve disease.

  5. Plasma and tissue oxidative stress index in patients with rheumatic and degenerative heart valve disease.

    Science.gov (United States)

    Rabus, Murat; Demirbağ, Recep; Sezen, Yusuf; Konukoğlu, Oğuz; Yildiz, Ali; Erel, Ozcan; Zeybek, Rahmi; Yakut, Cevat

    2008-12-01

    We investigated whether patients with rheumatic and degenerative heart valve disease (HVD) differed with regard to plasma and tissue oxidative stress index (OSI). The study included 56 patients who underwent valve replacement due to rheumatic (n=32; 15 males; mean age 47+/-10 years) and degenerative (n=24; 13 males; mean age 55+/-12 years) HVD. Plasma and tissue total oxidative status (TOS) and total antioxidative capacity (TAC) levels were measured and OSI was calculated. Patients with degenerative HVD had significantly higher age, increased interventricular septum thickness, and higher frequency of aortic stenosis, whereas the incidence of mitral stenosis was higher in patients with rheumatic HVD (p0.05). Tissue TAC was significantly lower in patients with rheumatic HVD (p=0.027), whereas tissue TOS and OSI were similar between the two HVD groups (p>0.05). In bivariate analysis, plasma OSI did not show any correlation with clinical, laboratory, and echocardiographic variables (p>0.05). Our data show that plasma and tissue OSI levels are similar in patients with rheumatic and degenerative HVD.

  6. Left ventricular function in patients with ventricular arrhythmias and aortic valve disease

    International Nuclear Information System (INIS)

    Santinga, J.T.; Kirsh, M.M.; Brady, T.J.; Thrall, J.; Pitt, B.

    1983-01-01

    Forty patients having aortic valve replacement were evaluated preoperatively for ventricular arrhythmia and left ventricular ejection fraction. Arrhythmias were classified as complex or simple using the Lown criteria on the 24-hour ambulatory electrocardiogram; ejection fractions were determined by radionuclide gated blood pool analysis and contrast angiography. The ejection fractions determined by radionuclide angiography were 59.1 +/- 13.1% for 26 patients with simple or no ventricular arrhythmias, and 43.9 +/- 20.3% for 14 patients with complex ventricular arrhythmias (p less than 0.01). Ejection fractions determined by angiography, available for 31 patients, were also lower in patients with complex ventricular arrhythmias (61.1 +/- 16.3% versus 51.4 +/- 13.4%; p less than 0.05). Seven of 9 patients showing conduction abnormalities on the electrocardiogram had complex ventricular arrhythmias. Eight of 20 patients with aortic stenosis had complex ventricular arrhythmias, while 2 of 13 patients with aortic insufficiency had such arrhythmias. It is concluded that decreased left ventricular ejection fraction, intraventricular conduction abnormalities, and aortic stenosis are associated with an increased frequency of complex ventricular arrhythmias in patients with aortic valve disease

  7. Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis.

    Science.gov (United States)

    Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang

    2014-06-01

    Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (PALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival.

  8. Candida and cardiovascular implantable electronic devices: a case of lead and native aortic valve endocarditis and literature review.

    Science.gov (United States)

    Glavis-Bloom, Justin; Vasher, Scott; Marmor, Meghan; Fine, Antonella B; Chan, Philip A; Tashima, Karen T; Lonks, John R; Kojic, Erna M

    2015-11-01

    Use of cardiovascular implantable electronic devices (CIED), including permanent pacemakers (PPM) and implantable cardioverter defibrillators (ICD), has increased dramatically over the past two decades. Most CIED infections are caused by staphylococci. Fungal causes are rare and their prognosis is poor. To our knowledge, there has not been a previously reported case of multifocal Candida endocarditis involving both a native left-sided heart valve and a CIED lead. Here, we report the case of a 70-year-old patient who presented with nausea, vomiting, and generalised fatigue, and was found to have Candida glabrata endocarditis involving both a native aortic valve and right atrial ICD lead. We review the literature and summarise four additional cases of CIED-associated Candida endocarditis published from 2009 to 2014, updating a previously published review of cases prior to 2009. We additionally review treatment guidelines and discuss management of CIED-associated Candida endocarditis. © 2015 Blackwell Verlag GmbH.

  9. Management of tricuspid regurgitation in congenital heart disease: is survival better with valve repair?

    Science.gov (United States)

    Said, Sameh M; Dearani, Joseph A; Burkhart, Harold M; Connolly, Heidi M; Eidem, Ben; Stensrud, Paul E; Schaff, Hartzell V

    2014-01-01

    Tricuspid valve (TV) regurgitation in congenital heart disease includes a heterogeneous group of lesions, and few series have documented the outcomes. We reviewed the records of 553 patients with congenital heart disease who had undergone TV surgery for tricuspid regurgitation from January 1993 to December 2010. Patients with Ebstein malformation were excluded. Their mean age was 32 ± 21 years, and 300 were female (54%). The most common diagnoses were conotruncal anomaly in 216 patients (39%), previous ventricular septal defect closure in 83 (15%), atrioventricular septal defect in 77 (14%), and pulmonary atresia with an intact ventricular septum in 11 (2%). Preoperative right-sided heart failure was present in 124 patients (22%), and 55 patients (10%) had pulmonary hypertension. TV repair was performed in 442 (80%) and TV replacement in 111 (20%) patients. Repeat sternotomy was performed in 415 patients (75%). Previous TV repair was present in 44 patients (8%); of these, 17 (38.6%) underwent repeat TV repair. The overall early mortality was 3.1% (17 patients) and was 2.5% for TV repair and 5.4% for TV replacement (P = .001). The mean follow-up period was 4.5 ± 4.1 years (maximum, 18). The overall survival at 1, 5, and 10 years was 97%, 93%, and 85%, respectively. Survival was better for patients with repair than with replacement. TV repair was an independent predictor of better survival (P = .001). Important tricuspid regurgitation can occur with a variety of congenital diagnoses. Early mortality is low and late survival is superior with tricuspid repair than with valve replacement. Surgical treatment of tricuspid regurgitation in congenital heart disease should be performed before the onset of heart failure. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  10. Experimental assessment of valve performance in healthy and diseased right ventricular outflow tracts using magnetic resonance velocimetry

    Science.gov (United States)

    Schiavone, Nicole; Elkins, Christopher; McElhinney, Doff; Eaton, John K.; Marsden, Alison

    2017-11-01

    Tetralogy of Fallot (ToF), the most common type of cyanotic congenital heart defect, affects 1 in every 2500 newborns annually and typically requires surgical repair of the right ventricular outflow tract (RVOT) and placement of an artificial pulmonary valve. All artificial valves are subject to dysfunction, but their longevity is highly variable. Clinical observation reveals large variations in RVOT anatomy in ToF patients, which may affect longevity. This work aims to experimentally assess the performance of artificial pulmonary valves in anatomically realistic healthy and diseased RVOT geometries using magnetic resonance velocimetry (MRV). With MRV, we can capture 3D, three-component, phase-averaged velocity fields in 3D printed RVOT geometries. The experiment is designed to ensure physiological flow rate and pressure waveforms, while the RVOT geometries are based on anatomies seen clinically in ToF patients. Two models are used in the current work: an idealized RVOT based on healthy subjects aged eleven to thirteen and a diseased geometry with a dilation of 150% in vessel diameter downstream of the pulmonary valve. We will also present preliminary rigid-wall blood flow simulations in each model, towards the ultimate goal of experimental validation of valve simulations.

  11. Comparative long-term results of mitral valve repair in adults with chronic rheumatic disease and degenerative disease: is repair for "burnt-out" rheumatic disease still inferior to repair for degenerative disease in the current era?

    Science.gov (United States)

    Dillon, Jeswant; Yakub, Mohd Azhari; Kong, Pau Kiew; Ramli, Mohd Faizal; Jaffar, Norfazlina; Gaffar, Intan Fariza

    2015-03-01

    Mitral valve repair is perceived to be of limited durability for advanced rheumatic disease in adults. We aim to examine the long-term outcomes of repair for rheumatic disease, identify predictors of durability, and compare with repair for degenerative disease. Rheumatic and degenerative mitral valve repairs in patients aged 40 years or more were prospectively analyzed. The primary outcomes investigated were mortality, freedom from reoperation, and valve failure. Logistic regression analysis was performed to define predictors of poor outcome. Between 1997 and 2011, 253 rheumatic and 148 degenerative mitral valves were repaired. The age of patients in both groups was similar, with a mean of 54.1 ± 8.4 years versus 55.6 ± 7.3 years (P = .49). Freedom from reoperation for rheumatic valves at 5 and 10 years was 98.4%, comparable to 95.3% (P = .12) for degenerative valves. Freedom from valve failure at 5 and 10 years was 91.4% and 81.5% for rheumatic repairs and 82.5% and 75.4% for degenerative repairs, respectively (P = .15). The presence of residual mitral regurgitation greater than 2+ before discharge was the only significant independent predictor of reoperation, whereas residual mitral regurgitation greater than 2+ and leaflet procedures were significant risk factors for valve failure. The durability of rheumatic mitral valve repair in the current era has improved and is comparable to the outstanding durability of repairs for degenerative disease, even in the adult rheumatic population. Modifications of standard repair techniques, adherence to the importance of good leaflet coaptation, and strict quality control with stringent use of intraoperative transesophageal echocardiography have all contributed to the improved long-term results. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. Native valve disease in patients with non-valvular atrial fibrillation on warfarin or rivaroxaban

    Science.gov (United States)

    Breithardt, Günter; Baumgartner, Helmut; Berkowitz, Scott D; Hellkamp, Anne S; Piccini, Jonathan P; Lokhnygina, Yuliya; Halperin, Jonathan L; Singer, Daniel E; Hankey, Graeme J; Hacke, Werner; Becker, Richard C; Nessel, Christopher C; Mahaffey, Kenneth W; Califf, Robert M; Fox, Keith A A; Patel, Manesh R

    2016-01-01

    Objective To compare the characteristics and outcomes of patients with atrial fibrillation (AF) and aortic stenosis (AS) with patients with AF with mitral regurgitation (MR) or aortic regurgitation (AR) and patients without significant valve disease (no SVD). Methods Using Rivaroxaban Once-Daily, Oral, Direct Factor Xa Inhibition Compared With Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation (ROCKET AF) data, we analysed efficacy and safety outcomes, adjusting hazard ratios (HRs) for potential confounders using Cox regression analysis. Results Among 14 119 intention-to-treat ROCKET AF trial patients, a trial that excluded patients with mitral stenosis or artificial valve prosthesis, 214 had AS with or without other valve abnormalities, 1726 had MR or AR and 12 179 had no SVD. After adjusting for prognostic factors, the composite of stroke, systemic embolism or vascular death increased approximately twofold in patients with AS (AS 10.84, MR or AR 4.54 and no SVD 4.31 events per 100 patient-years, p=0.0001). All-cause death also significantly increased (AS 11.22, MR or AR 4.90 and no SVD 4.39 events per 100 patient-years, p=0.0003). Major bleeding occurred more frequently in AS (adjusted HR 1.61, confidence intervals (CI) 1.03 to 2.49, p<0.05) and MR or AR (HR 1.30, 1.07 to 1.57, p<0.01) than in no SVD, but there was no difference between AS and MR or AR (HR 1.24, 0.78 to 1.97). The relative efficacy of rivaroxaban versus warfarin was consistent among patients with and without valvular disease. Rivaroxaban was associated with higher rates of major bleeding than warfarin in patients with MR or AR (HR 1.63, 1.15 to 2.31). Conclusions We found that patients with AF and AS on oral anticoagulants may have distinctly different efficacy and safety outcomes than patients with MR or AR or no SVD. Trial registration number NCT00403767; Post-results. PMID:26888572

  13. [Left-sided native valve endocarditis by coagulase-negative staphylococci: an emerging disease].

    Science.gov (United States)

    Haro, Juan Luis; Lomas, José M; Plata, Antonio; Ruiz, Josefa; Gálvez, Juan; de la Torre, Javier; Hidalgo-Tenorio, Carmen; Reguera, José M; Márquez, Manuel; Martínez-Marcos, Francisco; de Alarcón, Arístides

    2008-05-01

    To describe the epidemiological, clinical, and prognostic characteristics of patients with left-sided native valve endocarditis (LNVE) caused by coagulase-negative staphylococci (CoNS). Prospective multicenter study of endocarditis cases reported in the Andalusian Cohort for the Study of Cardiovascular Infections between 1984 and 2005. Among 470 cases of LNVE, 39 (8.3%) were caused by CoNS, a number indicating a 30% increase in the incidence of this infection over the last decade. The mean age of affected patients was 58.32 +/- 15 years and 27 (69.2%) were men. Twenty-one patients (53.8%) had previous known valve disease and half the episodes were considered nosocomial (90% of them from vascular procedures). Median time interval from the onset of symptoms to diagnosis was 14 days (range: 1-120). Renal failure (21 cases, 53.8%), intracardiac damage (11 cases, 28.2%), and central nervous system involvement (10 cases, 25.6%) were the most frequent complications. There were only 3 cases (7.7%) of septic shock. Surgery was performed in 18 patients (46.2%). Nine patients (23.1%) died, overall. Factors associated with higher mortality in the univariate analysis were acute renal failure (P = 0.023), left-sided ventricular failure (P = 0.047), and time prior to diagnosis less than 21 days (P = 0.018). As compared to LNVE due to other microorganisms, the patients were older (P = 0.018), had experienced previous nosocomial manipulation as the source of bacteremia (P < 0.001), and developed acute renal failure more frequently (P = 0.001). Mortality of LNVE due to CoNS was lower than mortality in Staphylococcus aureus infection, but higher than in Streptococcus viridans infection. Left-sided native valve endocarditis due to CoNS is now increasing because of the ageing of the population. This implies more frequent invasive procedures (mainly vascular) as a consequence of the concomitant disease. Nonetheless, the mortality associated with LNVE due to CoNS does not seem to be

  14. Angiotensin-converting enzyme activity in Cavalier King Charles Spaniels with an ACE gene polymorphism and myxomatous mitral valve disease.

    Science.gov (United States)

    Meurs, Kathryn M; Olsen, Lisbeth H; Reimann, Maria J; Keene, Bruce W; Atkins, Clarke E; Adin, Darcy; Aona, Brent; Condit, Julia; DeFrancesco, Teresa; Reina-Doreste, Yamir; Stern, Joshua A; Tou, Sandra; Ward, Jessica; Woodruff, Kathleen

    2018-02-01

    Myxomatous mitral valve disease (MMVD) is the most common heart disease in the dog. It is particularly common in the Cavalier King Charles Spaniel (CKCS) breed and affected dogs are frequently managed with angiotensin-converting enzyme inhibitors (ACE-I). We have previously identified a canine ACE gene polymorphism associated with a decrease in angiotensin-converting enzyme (ACE) activity. The aim of this study was to evaluate for the prevalence of the ACE polymorphism in CKCS with mitral valve disease and to determine whether the presence of the polymorphism is associated with alterations in ACE activity at different stages of cardiac disease. Seventy-three dogs with a diagnosis of mitral valve disease were evaluated and a blood sample was drawn for ACE polymorphism genotyping and ACE activity measurement. Forty-three dogs were homozygous for the ACE polymorphism; five were heterozygous and 25 were homozygous wild type. The mean age and the median severity of disease were not different for dogs with the polymorphism and dogs with the wild-type sequence. The median baseline ACE activity was significantly lower for the ACE polymorphism (27.0 U/l) than the wild-type sequence dogs (31.0 U/l) (P=0.02). Dogs with more severe disease and the ACE polymorphism had significantly lower levels of ACE activity than dogs with the wild-type sequence (P=0.03). The CKCS appears to have a high prevalence of the ACE variant. Dogs with the ACE variant had lower levels of ACE activity even in more advanced mitral valve disease than dogs without the variant. The clinical significance of this finding and its impact on the need for ACE-I in dogs with the polymorphism and heart disease deserves further study.

  15. Expression Profiling of Circulating MicroRNAs in Canine Myxomatous Mitral Valve Disease

    Directory of Open Access Journals (Sweden)

    Qinghong Li

    2015-06-01

    Full Text Available MicroRNAs (miRNAs are small non-coding RNAs that have shown promise as noninvasive biomarkers in cardiac disease. This study was undertaken to investigate the miRNA expression profile in dogs with myxomatous mitral valve disease (MMVD. 277 miRNAs were quantified using RT-qPCR from six normal dogs (American College of Veterinary Internal Medicine Stage A, six dogs with MMVD mild to moderate cardiac enlargement (ACVIM Stage B1/B2 and six dogs with MMVD and congestive heart failure (ACVIM Stage C/D. Eleven miRNAs were differentially expressed (False Discovery Rate < 0.05. Dogs in Stage B1/B2 or C/D had four upregulated miRNAs, including three cfa-let-7/cfa-miR-98 family members, while seven others were downregulated, compared to Stage A. Expression of six of the 11 miRNAs also were significantly different between dogs in Stage C/D and those in Stage B1/B2. The expression changes were greater as disease severity increased. These miRNAs may be candidates for novel biomarkers and may provide insights into genetic regulatory pathways in canine MMVD.

  16. Role of diastolic function indices in the risk stratification of patients with mixed aortic valve disease.

    Science.gov (United States)

    Egbe, Alexander C; Khan, Arooj R; Boler, Amber; Said, Sameh M; Geske, Jeffrey B; Miranda, William R; Akintoye, Emmanuel; Connolly, Heidi M; Warnes, Carole A; Oh, Jae K

    2018-06-01

    Determine the role of diastolic function indices in pre-operative and post-operative risk stratification in patients with moderate mixed aortic valve disease (MAVD). A retrospective study was conducted of asymptomatic patients with moderate MAVD (a combination of moderate aortic stenosis and moderate aortic regurgitation) and an ejection fraction of 50% or more who were followed up at Mayo Clinic from 1 January 2004, to 31 December 2013. A pre-requisite for inclusion in the study was assessment of diastolic function involving at least three of the following indices: tissue Doppler early diastolic velocity (e'), mitral inflow early velocity (E), tricuspid regurgitation velocity, and left atrial volume index. Primary endpoints were aortic valve replacement (AVR) or cardiac death while secondary endpoints were cardiovascular adverse events (CAEs) after AVR. We defined CAEs as stroke, heart failure hospitalization, severe left ventricular dysfunction, and cardiac death. There were 214 patients (age 61 ± 8 years, men 146 [68%]) followed for 6.1 ± 2.3 years during which 162 (76%) AVRs and 11 (5%) cardiac deaths occurred. The multivariable risk factors for cardiac death or AVR were relative wall thickness (RWT) > 0.42 [hazard ratio (HR), 1.88 [95% CI, 1.28-2.59]; P = 0.001] and average E/e' >14 (HR, 1.94 [95% CI, 1.29-3.01]; P = 0.02). Freedom from CAE after AVR was significantly lower in the patients with baseline RWT >0.42 or mean E/e' >14 than the other patients: 79% (95% CI 74-83%) vs. 94% (95% CI 89-98%) at 3 years (P = 0.03). The presence of RWT >0.42 or E/e' >14 identifies a high-risk patient subset whose risk for cardiovascular morbidities persists even after AVR.

  17. Valvular heart disease: assessment of valve morphology and quantification using MR

    International Nuclear Information System (INIS)

    Schwitter, J.

    2000-01-01

    For clinical evaluation and decision-making in patients with valvular heart disease, the diagnostic armamentarium expands steadily. This evolution makes it difficult to choose the most appropriate approach for a specific valvular lesion. It may also reflect our uncertainty of what are the findings that best predict clinical outcome of patients, e. g. after surgery. Accordingly, for each type of valvular lesion, some pathophysiological considerations are stated in order to derive the most important measures that would allow optimal guidance of patients. Based on these considerations the value of an MR study is discussed for each valvular lesion. Newest advances in MR technology allow for highly accurate measurements of regurgitant volumes and hence, MR may be the method of choice for a quantitative evaluation of regurgitant valves. For assessment of stenosis severity, measurement of transvalvular pressure gradient is an appropriate measure and MR may not confer benefits over echocardiography, provided the ultrasound window is adequate (and stroke volume is in the normal range). With respect to surgical treatment, valvular morphology is of pivotal importance, particularly for the mitral valve, and echocardiography still appears to be the first line method. Little data relate lesion severity and/or morphology to clinical outcome. Conversely, the extent of cardiac adaptation to pressure- and/or volume-overload, i. e. ventricular remodeling, is a strong predictor of outcome, and is therefore most important for final judgement of the patient. For assessment of left and right ventricular remodeling, echocardiography typically provides all the necessary information. However, in special cases with discrepant findings, with inadequate ultrasound window, or in the preoperative work-up, MR may provide important information regarding cardiac adaptation to valvular lesion. (orig.) [de

  18. Outcomes of Patients With Severe Chronic Lung Disease Who Are Undergoing Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Suri, Rakesh M; Gulack, Brian C; Brennan, J Matthew; Thourani, Vinod H; Dai, Dadi; Zajarias, Alan; Greason, Kevin L; Vassileva, Christina M; Mathew, Verghese; Nkomo, Vuyisile T; Mack, Michael J; Rihal, Charanjit S; Svensson, Lars G; Nishimura, Rick A; O'Gara, Patrick T; Holmes, David R

    2015-12-01

    In this study, we sought to determine the clinical outcomes after transcatheter aortic valve replacement (TAVR) among patients with chronic lung disease (CLD) and to evaluate the safety of transaortic versus transapical alternate access approaches in patients with varying severities of CLD. Clinical records for patients undergoing TAVR from 2011 to 2014 in The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry were linked to Medicare hospital claims (n = 11,656). Clinical outcomes were evaluated across strata of CLD severity, and the risk-adjusted association between access route and post-TAVR mortality was determined among patients with severe CLD. In this cohort (median age, 84 years; 51.7% female), moderate to severe CLD was present in 27.7% (14.3%, moderate; 13.4%, severe). Compared with patients with no or mild CLD, patients with severe CLD had a higher rate of post-TAVR mortality to 1-year (32.3% versus 21.0%; adjusted hazard ratio [HR], 1.48; 95% confidence interval [CI], 1.31 to 1.66), as did those with moderate CLD (25.5%; adjusted HR, 1.16; 95% CI, 1.03 to 1.30). The adjusted rate of mortality was similar for transapical versus transaortic approaches to 1 year (adjusted HR, 1.17; 95% CI, 0.83 to 1.65). Moderate or severe CLD is associated with an increased risk of death to 1-year after TAVR, and among patients with severe CLD, the risk of death appears to be similar with either transapical or transaortic alternate-access approaches. Further study is necessary to understand strategies to mitigate risk associated with CLD and the long-term implications of these findings. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Biopterin status in dogs with myxomatous mitral valve disease is associated with disease severity and cardiovascular risk factors

    DEFF Research Database (Denmark)

    Reimann, Maria Josefine; Häggström, J.; Mortensen, Alan

    2014-01-01

    BACKGROUND: Endothelial dysfunction (ED) has been suggested to be associated with myxomatous mitral valve disease (MMVD) in dogs. Tetrahydrobiopterin (BH4) is an important cofactor for production of the endothelium-derived vasodilator nitric oxide (NO). Under conditions of oxidative stress, BH4...... is oxidized to the biologically inactive form dihydrobiopterin (BH2). Thus, plasma concentrations of BH2 and BH4 may reflect ED and oxidative stress. OBJECTIVE: To determine plasma concentrations of BH2 and BH4 in dogs with different degrees of MMVD. ANIMALS: Eighty-four privately owned dogs grouped according...... to ACVIM guidelines (37 healthy control dogs including 13 Beagles and 24 Cavalier King Charles Spaniels [CKCSs], 33 CKCSs with MMVD of differing severity including 18 CKCSs [group B1] and 15 CKCSs [group B2], and 14 dogs of different breeds with clinical signs of congestive heart failure [CHF] because...

  20. Mitral valve regurgitation

    Science.gov (United States)

    ... and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... the middle Heart, front view References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  1. CLINICAL AND FUNCTIONAL ASSESSMENT OF THE BIOLOGICAL PROSTHESIS “ASPIRE” FOR SURGICAL CORRECTION OF MITRAL VALVE DISEASE

    Directory of Open Access Journals (Sweden)

    S. G. Esin

    2015-01-01

    Full Text Available Aim: To assess clinical and functional efficacy of implanted biological prosthesis “ASPIRE” (manufactured by Vascutek for correction of mitral valve disease.Materials and methods: From October 2008 to December 2013, biological prostheses “ASPIRE” (Vascutek were implanted to 34 patients with mitral valve disease (mean age 63.59 ± 4.96 years, 79.4% female. From these, 24 patients had mitral stenosis and 10 patients had mitral insufficiency. 73.5% of all patients had heart failure Strazhesko-Vasilenko IIA grade and 85.3% of patients had chronic heart failure NYHA III. Isolated mitral valve replacement was performed only in 8 (23.5% of patients. In 22 (64.7% of cases mitral valve replacement was combined with tricuspid valvuloplasty in various modifications. Duration of cardiopulmonary bypass and of aortic clamping was 88.09 ± 25.95 and 65.68 ± 25.51 minutes, respectively. Before and after surgery all patients underwent echocardiographic assessment and clinical assessment of their general status.Results: In-hospital mortality was 5.88% (n = 2 and was related to multiorgan failure in the early postoperative period. All 32 (94.12% surviving patients improved with decrease or complete disappearance of heart failure. Postoperative complications were typical for cardiac surgery. There were no episodes of embolism, structural dysfunction, thrombosis of the prosthesis and endocarditis of the prosthesis in the early postoperative period. Pressure gradients across prosthetic valves were not high and corresponded to good clinical and hemodynamic results in the early postoperative period.Conclusion: Taking into account good immediate results of mitral valve replacement, as well as no need in lifelong anticoagulation in patients with multiple concomitant disorders, implantation of the biological prosthesis “ASPIRE” (Vascutek could become a procedure of choice for correction of valve abnormalities in patients above 65 years. For more comprehensive

  2. Thallium - 201 miocardial perfusion scintigraphy in patients with mitral valve prolapse, with and without coronary artery disease

    International Nuclear Information System (INIS)

    Moraes, A.G. de; Sousa, J.E.M.R.; Thom, A.F.; Martins, L.R.F.; Meneghelo, R.S.; Pimentel Filho, W.A.; Marioni Filho, H.; Gimenes, V.M.L.; Pontes Junior, S.C.

    1981-01-01

    Thirty patients with precordial pain and mitral valve prolapse diagnosed by cineangiography and M-mode echocardiography were submitted to Thallium-201 myocardial stress perfusion scintillography. They were divided into two groups: group I - eighteen patients with mitral valve prolapse and normal coronary arteries, of which ten presented positive exercise stress test (55.6%); eight patients had a negative exercise test. Thallium-201 myocardial stress perfusion scintillagraphy was normal in 14 (77.8%) patients, and four with positive stress perfursion scintillography, (three with inferior perfusion defects and one with a lateral one); group II - twelve patients with mitral valve prolapse and severe coronary artery disease (stenosis >= 60% in at least one main vessel of the coronary circulation), of which nine presented positive exercise stress test (75%) and three negative. Thallium-201 exercise myocardial perfusion scintillography was abnormal in nine (75%), six with stress induced ischemia and three with resting defect. Myocardial perfusion scintillography with Thallium-201 was more sensitive to detect the presence of coronary artery disease in patients with mitral valve prolapse (MVP) than the exercise stress test in spite of the fact that a small number of patients (22%) with MVP and normal coronary arteries exhibited abnormal myocardial stress perfusion during scintillography. (Author) [pt

  3. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    International Nuclear Information System (INIS)

    Ruparelia, Neil; Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio; Latib, Azeem

    2015-01-01

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  4. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    Energy Technology Data Exchange (ETDEWEB)

    Ruparelia, Neil [San Raffaele Scientific Institute, Milan (Italy); Imperial College, London (United Kingdom); Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio [San Raffaele Scientific Institute, Milan (Italy); Latib, Azeem, E-mail: info@emocolumbus.it [San Raffaele Scientific Institute, Milan (Italy)

    2015-09-15

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  5. Aldosterone breakthrough in dogs with naturally occurring myxomatous mitral valve disease.

    Science.gov (United States)

    Ames, M K; Atkins, C E; Eriksson, A; Hess, A M

    2017-06-01

    Aldosterone breakthrough (ABT) is the condition in which angiotensin converting enzyme inhibitors (ACEIs) and/or angiotensin receptor blockers fail to effectively suppress the activity of the renin angiotensin aldosterone system. The objective of this study was to determine if ABT occurs in dogs with naturally occurring myxomatous mitral valve disease receiving an ACEI, using the urine aldosterone to creatinine ratio (UAldo:C) as a measure of renin angiotensin aldosterone system activation. This study includes 39 dogs with myxomatous mitral valve disease. A UAldo:C cut-off definition (derived from a normal population of healthy, adult, and client-owned dogs) was used to determine the prevalence of ABT in this population. Spearman analysis and univariate logistic regression were used to evaluate the relationship between UAldo:C and ABT (yes/no) and eight variables (age, serum K + concentration, serum creatinine concentration, ACEI therapy duration and ACEI dosage, furosemide therapy duration and furosemide dosage, and urine sample storage time). Finally, the UAldo:C in dogs receiving spironolactone, as part congestive heart failure (CHF) therapy, was compared to dogs with CHF that were not receiving spironolactone. The prevalence of ABT was 32% in dogs with CHF and 30% in dogs without CHF. There was no relationship between either the UAldo:C or the likelihood of ABT and the eight variables. Therapy with spironolactone lead to a significant elevation of the UAldo:C. Using the UAldo:C and a relatively stringent definition of ABT, it appears that incomplete RAAS blockade is common in dogs with MMVD receiving an ACEI. The prevalence of ABT in this canine population mirrors that reported in humans. While the mechanism of ABT is likely multifactorial and still poorly understood, the proven existence of ABT in dogs offers the potential to improve the prognosis for MMVD with the addition of a mineralocorticoid receptor blocker to current therapeutic regimens

  6. Surgical experience with diseases of the tricuspid valve. Cross-sectional and Doppler echocardiographic evaluation following DeVega's repair.

    Science.gov (United States)

    Kulshrestha, P; Das, B; Iyer, K S; Sampathkumar, A; Sharma, M L; Rao, I M; Kaul, U; Srivastava, S; Bhatia, M L; Venugopal, P

    1989-04-01

    Seventy-eight patients undergoing mitral valve surgery with or without replacement of the aortic valve also underwent procedures on the tricuspid valve over a period of 10 years. All patients were in functional class III or IV preoperatively. The procedures were performed in all patients with organic disease of the tricuspid valve (N = 44) and in those with moderate or severe functional tricuspid valvar regurgitation (N = 34). Seventy-one patients underwent DeVega's annuloplasty with or without commissurotomy. The overall mortality was 11.5%. 65 long-term survivors were followed up for a period of 6 months to 10 years (mean 5.3 years). Sixty-three patients were in functional class I or II at the last follow-up. Six patients had clinical evidence of mild to moderate tricuspid regurgitation. Regression of cardiomegaly (as judged by the chest radiograph and right ventricular hypertrophy seen in the electrocardiogram) was evident in most cases. Fifty-one of 54 patients evaluated by cross-sectional echocardiography were reported to have a functionally normal tricuspid valve. Doppler echocardiography in 28 patients showed no significant tricuspid regurgitation or stenosis in 26 patients. Eleven consecutive patients undergoing DeVega's annuloplasty were studied prospectively with pre- and postoperative Doppler echocardiography. Good correlation existed between right ventricular systolic pressures predicted by Doppler with those obtained preoperatively at cardiac catheterization. Postoperative Doppler echocardiography in these 11 patients showed complete restoration of competence of the tricuspid valve as well as normalisation of the right ventricular systolic pressure in 10 patients.

  7. Quality of Life Score as a Predictor of Death in Dogs with Degenerative Mitral Valve Disease.

    Science.gov (United States)

    Strunz, Célia M C; Marcondes-Santos, Mário; Takada, Julio Yoshio; Fragata, Fernanda S; Mansur, Antônio de Pádua

    2017-04-01

    The knowledge of the variables predicting mortality is important in clinical practice and for therapeutic monitoring in mitral valve disease. To determine whether a quality of life score evaluated with the Functional Evaluation of Cardiac Health questionnaire would predict mortality in dogs with degenerative mitral valve disease (DMVD). Thirty-six client-owned dogs with mitral valve disease underwent clinical, laboratory, and echocardiographic evaluations at baseline and were monitored for 6 months. Cardiovascular death was the primary outcome. The 36 dogs were classified as survivors or nonsurvivors. Higher values of the following variables were obtained at baseline in the nonsurviving group (12 dogs): amino-terminal pro-B-type natriuretic peptide (NT-proBNP) levels, plasma norepinephrine, heart rate, quality of life score, diastolic left ventricular internal dimension to aortic root ratio, systolic left ventricular internal dimension to aortic root ratio, and left atrium to aortic root ratio. NT-proBNP levels and quality life score were independently associated with death in the multivariable analysis. The quality life score was an independent variable for cardiac death in dogs with DMVD. This result is encouraging, as this score is easy to apply and does not require any technology, only a veterinarian and an observant owner. O conhecimento das variáveis preditoras de mortalidade é importante para a prática clínica e para o acompanhamento terapêutico na doença da valva mitral. Determinar se um escore de qualidade de vida avaliado com o Functional Evaluation of Cardiac Health poderia auxiliar na predição de mortalidade em cães com doença degenerativa da valva mitral (DDVM). Trinta e seis cães de estimação com doença valvar mitral foram submetidos a avaliação clínica, laboratorial e ecocardiográfica no início do estudo e monitorizados durante 6 meses. A morte cardiovascular foi o desfecho primário. Os 36 cães foram classificados como

  8. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  9. Relation of Aortic Valve and Coronary Artery Calcium in Patients With Chronic Kidney Disease to the Stage and Etiology of the Renal Disease

    NARCIS (Netherlands)

    Piers, Lieuwe H.; Touw, Hugo R. W.; Gansevoort, Ron; Franssen, Casper F. M.; Oudkerk, Matthijs; Zijlstra, Felix; Tio, Rene A.

    2009-01-01

    Patients with chronic renal failure have increased cardiac calcium loads. Previous studies have investigated the prevalence and quantitative extent of aortic valve calcium (AVC) and coronary artery calcium (CAC) in patients with various stages of chronic kidney disease (CKD). However, the impact of

  10. Early and mid-term results of autograft rescue by Ross reversal: A one-valve disease need not become a two-valve disease.

    Science.gov (United States)

    Hussain, Syed T; Majdalany, David S; Dunn, Aaron; Stewart, Robert D; Najm, Hani K; Svensson, Lars G; Houghtaling, Penny L; Blackstone, Eugene H; Pettersson, Gösta B

    2018-02-01

    Risk of reoperation and loss of a second native valve are major drawbacks of the Ross operation. Rather than discarding the failed autograft, it can be placed back into the native pulmonary position by "Ross reversal." We review our early and mid-term results with this operation. From 2006 to 2017, 39 patients underwent reoperation for autograft dysfunction. The autograft was successfully rescued in 35 patients: by Ross reversal in 30, David procedure in 4, and autograft repair in 1. Medical records were reviewed for patient characteristics (mean age was 46 ± 13 years, range 18-67 years, and 23 were male), previous operations, indications for reoperation, hospital outcomes, and echocardiographic findings for the 30 patients undergoing successful Ross reversal. Follow-up was 4.1 ± 3.5 years (range 7 months-11 years). Median interval between the original Ross procedure and Ross reversal was 12 years (range 5-19 years). Eight patients also had absolute indications for replacement of the pulmonary allograft. There was no operative mortality. One patient required reoperation for bleeding. Another had an abdominal aorta injury from use of an endoballoon clamp. There was no other major postoperative morbidity, and median postoperative hospital stay was 7.2 days (range 4-41 days). No patient required reoperation during follow-up. Twenty-four patients had acceptable pulmonary valve function, and 6 had clinically well-tolerated moderate or severe pulmonary regurgitation. Ross reversal can be performed with low morbidity and acceptable pulmonary valve function, reducing patient risk of losing 2 native valves when the autograft fails in the aortic position. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Heart valve disease associated with treatment with ergot-derived dopamine agonists: a clinical and echocardiographic study of patients with Parkinson's disease

    DEFF Research Database (Denmark)

    Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, E

    2007-01-01

    regurgitation (n = 5) was found in 22 EDDA patients (25.9%). Two patients had coexistent moderate mitral and tricuspid valvular regurgitation. Two non-EDDA patients had moderate valve insufficiency (3.8%, P insufficiency in the EDDA patients was 7....... Interventions. Patients were screened for valvular heart disease by clinical means and by examiner-blinded echocardiography. Main outcome measure was valvular regurgitation revealed by echocardiography. RESULTS: Severe aortic regurgitation (n = 4) or moderate aortic (n = 12), mitral (n = 3) or tricuspidal valve...

  12. Study of prognostic significance of antenatal ultrasonography and renin angiotensin system activation in predicting disease severity in posterior urethral valves

    Directory of Open Access Journals (Sweden)

    Divya Bhadoo

    2015-01-01

    Full Text Available Aims: Study on prognostic significance of antenatal ultrasonography and renin angiotensin system activation in predicting disease severity in posterior urethral valves. Materials and Methods: Antenatally diagnosed hydronephrosis patients were included. Postnatally, they were divided into two groups, posterior urethral valve (PUV and non-PUV. The studied parameters were: Gestational age at detection, surgical intervention, ultrasound findings, cord blood and follow up plasma renin activity (PRA values, vesico-ureteric reflux (VUR, renal scars, and glomerular filtration rate (GFR. Results: A total of 25 patients were included, 10 PUV and 15 non-PUV. All infants with PUV underwent primary valve incision. GFR was less than 60 ml/min/1.73 m 2 body surface area in 4 patients at last follow-up. Keyhole sign, oligoamnios, absent bladder cycling, and cortical cysts were not consistent findings on antenatal ultrasound in PUV. Cord blood PRA was significantly higher (P < 0.0001 in PUV compared to non-PUV patients. Gestational age at detection of hydronephrosis, cortical cysts, bladder wall thickness, and amniotic fluid index were not significantly correlated with GFR while PRA could differentiate between poor and better prognosis cases with PUV. Conclusions: Ultrasound was neither uniformly useful in diagnosing PUV antenatally, nor differentiating it from cases with non-PUV hydronephrosis. In congenital hydronephrosis, cord blood PRA was significantly higher in cases with PUV compared to non-PUV cases and fell significantly after valve ablation. Cord blood PRA could distinguish between poor and better prognosis cases with PUV.

  13. A simulation environment for dry-expansion evaporators with application to the design of autotuning control algorithms for electronic expansion valves

    Energy Technology Data Exchange (ETDEWEB)

    Beghi, Alessandro [Dipartimento di Ingegneria dell' Informazione, Universita di Padova, via Gradenigo 6/B, I-35131 Padova (Italy); Cecchinato, Luca [Dipartimento di Fisica Tecnica, Universita di Padova, via Venezia 1, I-35131 Padova (Italy)

    2009-11-15

    In this paper some results of a research project aimed at deriving high-performance, adaptive control algorithms for electronic expansion valves (EEVs) to be used in finned-coiled, dry-expansion evaporators for refrigeration systems are reported. With the aim of developing a software environment that can be used for controller design, rapid prototyping, optimization of data collection and test design, virtual prototyping approach to design was adopted. The development of a distributed dynamic simulation model of the evaporator coupled with an electronic expansion valve, and its use for deriving autotuning PID control algorithms is described. Experimental results confirm the effectiveness of this kind of approach. (author)

  14. Relationship between aortic valve calcification and the severity of coronary atherosclerotic disease.

    Science.gov (United States)

    Qian, Juying; Chen, Zhangwei; Ge, Junbo; Ma, Jianying; Chang, Shufu; Fan, Bing; Liu, Xuebo; Ge, Lei

    2010-07-01

    Aortic valve calcification (AVC), which has been confirmed to be associated with various risk factors of cardiac disease, is common in the elderly and associated with increased cardiovascular mortality. It has been hypothesized that AVC is associated with coronary atherosclerotic disease, and its severity. Between July 2007 and November 2007, a total of 235 patients with chest pain or chest distress were admitted to the authors' institution for coronary angiography. The severity of coronary atherosclerotic disease (CAD) was evaluated by the Gensini score, the number of stenosed vessels, and the prevalence of total occlusion. All patients underwent transthoracic echocardiography to detect AVC. Patients with CAD had a higher prevalence of AVC than those without CAD (44% versus 26%, p = 0.005). Likewise, the prevalence of AVC was significantly higher in patients with a higher Gensini score than in those with a lower score. Patients with AVC had a higher prevalence of CAD, and higher Gensini scores and numbers of stenosed coronary arteries, even after stratification by age (65 years). On multivariable logistic regression analysis for CAD, the odds ratio (OR) of AVC was 2.315 (95% confidence interval (CI): 1.158-4.629, p = 0.018); this value was higher than that for total cholesterol (OR = 1.637, p = 0.008), lipoprotein-a (OR = 1.003, p = 0.015) and fibrinogen (OR = 1.009, p = 0.006), and marginally less than that for male gender (OR = 2.665, p = 0.005). Patients with AVC had a higher prevalence and greater severity of CAD.

  15. Comparison of biatrial and left atrial radiofrequency ablation in patients with heart valves diseases

    Directory of Open Access Journals (Sweden)

    А. В. Богачев-прокофьев

    2015-10-01

    Full Text Available We analysed results of left atrial and biatrial anatomic scheme of radiofrequency (RF ablation of the atria in patients with valvular heart. From 2007 to 2011, RF ablation procedure performed 283 patients with atrial fibrillation and heart valve disease. Patients were divided into two groups - group I performed a complete circuit biatrial procedure (procedure maze IV - 131 patients, in group II only ablation of the left atrium -152 patients. Most of the patients had long-term persistent AF. The main problem of early postoperative period is dysfunction of pacemaker complex, which observed in 64.9% and 50.7% patients for group I and II, respectively (p = 0.031. Permanent dysfunction of pacemaker complex required implantation of permanent pacemaker (9.2% and 4.6% of cases for group I and II, respectively, p = 0,023. Predictors of dysfunction of the pacemaker complex were biatrial execution method and duration of AF. Freedom from AF and AT during 36 months after surgery was 80.4% for patients in group I and 78.5% for patients in group II, with no statistically significant difference (log-rank test, p = 0.621. Atrial transport function has not revealed that the active fraction of the right atrium was 29.8% higher than in group II in the early postoperative phase and by 17.9% in the long term, with no difference between groups for the left atrium has been received.

  16. Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair

    OpenAIRE

    Mustafa Zakkar; Mustafa Zakkar; Vito Domanico Bruno; Alexandru Ciprian Visan; Stephanie Curtis; Gianni Angelini; Emmanuel Lansac; Serban Stoica

    2018-01-01

    Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population...

  17. Abnormal antenatal sonogram: an indicator of disease severity in children with posterior urethral valves

    International Nuclear Information System (INIS)

    Harvie, S.; McLeod, L.; Acott, P.; Walsh, E.; Abdolell, M.; Macken, M.B.

    2009-01-01

    To review the association of an abnormal prenatal sonogram with most recent serum creatinine in patients with proven posterior urethral valves (PUV). Since 1992, all live-born patients between 1992-2004 with clinically proven PUV, with postnatally proven PUV, from 2 pediatric tertiary care centers, were reviewed for age at diagnosis, most recent serum creatinine, presence of chronic renal failure (CRF) (serum creatinine >2 standard deviations above normal for age), or end stage renal disease (dialysis or transplant). Available antenatal reports from the 2 centres and surrounding community hospitals were reviewed for gestational age (GA) at the time of ultrasound, volume of amniotic fluid, and urinary-tract abnormality. Thirty-four patients with proven PUV and prenatal sonograms were identified (1992-2004). Eighteen patients had abnormalities on their prenatal sonogram, with poor outcome in 5 (mean follow-up, 8 years [1-13 y]). No specific features were identified on prenatal sonogram. Sixteen patients had normal prenatal sonograms, with poor outcomes in 2 (mean follow-up, 8 years [3-13 y]). There is an increased risk of an abnormal serum creatinine among those patients with an abnormal prenatal study, odds ratio (OR) 2.6 (95% confidence interval, 0.35-32). PUV represents a spectrum of disease severity. A normal prenatal ultrasound does not preclude PUV. The majority of patients with a normal prenatal examination have good outcomes. The OR suggests that there may be increased risk for poor outcome in those with an abnormal prenatal examination. A multicenter study is necessary to obtain a larger sample size and more precise ORs. (author)

  18. Abnormal antenatal sonogram: an indicator of disease severity in children with posterior urethral valves

    Energy Technology Data Exchange (ETDEWEB)

    Harvie, S. [Peterborough Health Centre, Dept. of Radiology, Peterborough, Ontario (Canada); McLeod, L. [IWK Health Centre, Dept. of Obstetrics and Gynaecology, Halifax, Nova Scotia (Canada); Acott, P. [IWK Health Centre, Dept. of Nephrology, Halifax, Nova Scotia (Canada); Walsh, E. [Dr. Charles A. Janeway Children' s Health Centre, Dept. of Radiology, St. John' s, Newfoundland (Canada); Abdolell, M. [QE II Health Sciences Centre, Dept. of Radiology, Halifax, Nova Scotia (Canada); Macken, M.B., E-mail: mmacken@dal.ca [IWK Health Centre, Dept. of Diagnostic Imaging, Halifax, Nova Scotia (Canada)

    2009-10-15

    To review the association of an abnormal prenatal sonogram with most recent serum creatinine in patients with proven posterior urethral valves (PUV). Since 1992, all live-born patients between 1992-2004 with clinically proven PUV, with postnatally proven PUV, from 2 pediatric tertiary care centers, were reviewed for age at diagnosis, most recent serum creatinine, presence of chronic renal failure (CRF) (serum creatinine >2 standard deviations above normal for age), or end stage renal disease (dialysis or transplant). Available antenatal reports from the 2 centres and surrounding community hospitals were reviewed for gestational age (GA) at the time of ultrasound, volume of amniotic fluid, and urinary-tract abnormality. Thirty-four patients with proven PUV and prenatal sonograms were identified (1992-2004). Eighteen patients had abnormalities on their prenatal sonogram, with poor outcome in 5 (mean follow-up, 8 years [1-13 y]). No specific features were identified on prenatal sonogram. Sixteen patients had normal prenatal sonograms, with poor outcomes in 2 (mean follow-up, 8 years [3-13 y]). There is an increased risk of an abnormal serum creatinine among those patients with an abnormal prenatal study, odds ratio (OR) 2.6 (95% confidence interval, 0.35-32). PUV represents a spectrum of disease severity. A normal prenatal ultrasound does not preclude PUV. The majority of patients with a normal prenatal examination have good outcomes. The OR suggests that there may be increased risk for poor outcome in those with an abnormal prenatal examination. A multicenter study is necessary to obtain a larger sample size and more precise ORs. (author)

  19. Pulmonary valve stenosis

    Science.gov (United States)

    ... surgery - discharge Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  20. Disappearance of electrocardiographic abnormalities associated with the arrhythmic pattern of a Barlow disease after surgical mitral valve repair

    Directory of Open Access Journals (Sweden)

    Matteo Augello

    2017-04-01

    Full Text Available We describe the case of a 46-year old female with a Barlow’s disease (MVP characterized by systolic curling of posterior left ventricular (LV wall + significant mitral annular disjunction + complex ventricular arrhythmias + syncope + inverted T waves in inferolateral leads in whom a successful surgical mitral valve rapair determined the disappearance not only of the echocardiographic but also the electrocardiographic abnormalities (in particular the inferolateral T waves inversion on basal electrocardiogram and the complex basal arrhythmic pattern. This case demonstrates that electrocardiographic abnormalities may disappear after the surgical correction of the mechanical stretch imposed on the inferior LV free wall by the prolapsing mitral valve leaflets. Electrocardiographic changes remain an important and easy marker to recognize for the identification of a high-risk subgroup of MVP patients.

  1. Brain-natriuretic peptide and cyclic guanosine monophosphate as biomarkers of myxomatous mitral valve disease in dogs

    DEFF Research Database (Denmark)

    Moesgaard, Sophia Gry; Falk, Bo Torkel; Teerlink, Tom

    2011-01-01

    Elevations in the plasma concentrations of natriuretic peptides correlate with increased severity of myxomatous mitral valve disease (MMVD) in dogs. This study correlates the severity of MMVD with the plasma concentrations of the biomarkers N-terminal fragment of the pro-brain-natriuretic peptide...... (NT-proBNP) and its second messenger, cyclic guanosine monophosphate (cGMP). Furthermore, the l-arginine:asymmetric dimethylarginine (ADMA) ratio was measured as an index of nitric oxide availability. The study included 75 dogs sub-divided into five groups based on severity of MMVD as assessed...... by clinical examination and echocardiography. Plasma NT-proBNP and cGMP concentrations increased with increasing valve dysfunction and were significantly elevated in dogs with heart failure. The cGMP:NT-proBNP ratio decreased significantly in dogs with heart failure, suggesting the development of natriuretic...

  2. The Burden of Pulmonary Hypertension in Patients with Degenerative Mitral Valve Disease in Enugu South-East Nigeria: An Echocardiographic Based Study.

    Science.gov (United States)

    Ejim, E C; Oguanobi, N I

    2016-01-01

    Pulmonary hypertension is a common complication of degenerative mitral valve disease, and contributes significantly to both morbidity and mortality. The use of medications for reduction of pulmonary pressure in patients is not a common practice by most physicians in this part of the world because of the absence of data on pulmonary hypertension. The authors set out to find the prevalence of pulmonary hypertension in patients with degenerative mitral valve disease and to determine if there are gender differences in affectation. This will form a basis for future research on the management of pulmonary hypertension in sub-Saharan Africa. The echocardiographic records of 1390 patients carried out over a period of 4 years were retrospectively reviewed. The examinations were done with a Logic 500 MD echocardiographic machine. Tricuspid valve regurgitation velocity above 250 cm/s defined pulmonary hypertension. Data obtained included presence of degenerative mitral valve disease, pulmonary hypertension, age, and gender. A total of 1390 echocardiogram reports done at Conquest Medical Imaging, Enugu, from July 2009 to August 2013 were retrospectively reviewed. Degenerative mitral valve disease was noted in 18.7% of the patients, (259/1390) made up of 149 males and 110 females with a mean age of 68.3 (14.4) years. Pulmonary hypertension was present in 30% of the patients (78/259) and affected males more than females. Pulmonary hypertension is common in patients with degenerative mitral valve disease in Enugu, and affects males more than females.

  3. Prevalence and severity of coronary artery disease in diabetic patients with aortic valve calcification.

    Science.gov (United States)

    Chen, Zhang-wei; Qian, Ju-ying; Jian, Ying; Ge, Lei; Liu, Xue-bo; Shu, Xian-hong; Ge, Junbo

    2011-02-01

    Aortic valve calcification (AVC) is common in the elderly and associated with increased cardiovascular mortality, while diabetes is one of the confirmed risk factors for coronary artery disease (CAD). In this study, we aimed to evaluate the prevalence and severity of CAD in type-2 diabetic patients with AVC. From June to December in 2007, a total of 325 consecutive patients with chest pain or chest distress were admitted for coronary angiography. The severity of CAD was evaluated by the Gensini score and the number of stenosed vessels. All patients underwent transthoracic echocardiography for detecting AVC. Compared with the patients without diabetes (n = 221), the type-2 diabetic patients (n = 104) had a similar prevalence of CAD (66.5% vs. 72.1%, P = 0.312). Further classified by the presence of AVC, patients with AVC had a higher prevalence of CAD, average Gensini score and the number of stenosed vessels, both in the group with and without diabetes. It was also demonstrated that the odds ratio (OR) of AVC for CAD in the diabetic patients was higher than in the non-diabetic ones (3.405 vs 2.515) after chi-square analysis (single-variable). However, at multivariable logistic regression analysis for CAD, the OR of AVC was 3.757 (P = 0.03) in diabetic group, while it did not achieve statistical significance in the non-diabetic group (OR = 2.130, P= 0.074). Type-2 diabetic patients with AVC had a higher prevalence of and more severe CAD.

  4. Ahmed Glaucoma Valve Implantation for Uveitic Glaucoma Secondary to Behçet Disease.

    Science.gov (United States)

    Satana, Banu; Yalvac, Ilgaz S; Sungur, Gulten; Eksioglu, Umit; Basarir, Berna; Altan, Cigdem; Duman, Sunay

    2015-01-01

    To evaluate outcomes of patients with uveitic glaucoma secondary to Behçet disease (BD) who underwent Ahmed glaucoma valve (AGV) implantation. A retrospective chart review of 14 eyes of 10 patients with uveitic glaucoma associated with BD who underwent AGV implantation at a tertiary referral center. Treatment success was defined as intraocular pressure (IOP) between 6 and 21 mm Hg with or without antiglaucoma medication, without further additional glaucoma surgery or loss of light perception. The main outcome measures were IOP, best-corrected visual acuity measured with Snellen charts, and number of glaucoma medications. Mean duration of postoperative follow-up was 18.2±6.6 months (range, 6 to 31 mo). Of the 14 eyes, 10 (71.4%) were pseudophakic and 5 (35.7%) had primary AGV implantation without a history of previous glaucoma surgery. At the most recent follow-up visit, 13 of the 14 eyes had an IOP between 6 and 21 mm Hg. Mean IOP was significantly reduced during follow-up, as compared with preoperative values (P≤0.005). The cumulative probability of surgical success rate was 90.9% at 18 months based on Kaplan-Meier survival analysis. The mean number of antiglaucoma medications required to achieve the desired IOP decreased from 3.4±0.5 preoperatively to 1.0±1.1 postoperatively (P≤0.05). Visual acuity loss of >2 lines occurred in 4 eyes (28.5%) due to optic atrophy associated with retinal vasculitis. Temporary hypotony developed during follow-up in 4 eyes (28.5%) at first postoperative week. For the management of uveitic glaucoma associated with BD, AGV implantation is a successful method for glaucoma control but requires additional surgical interventions for high early hypotony rates.

  5. Impacts of endoscopic gastroesophageal flap valve grading on pediatric gastroesophageal reflux disease.

    Directory of Open Access Journals (Sweden)

    Kai-Chi Chang

    Full Text Available Gastroesophageal flap valve (GEFV endoscopic grading is reported to be associated with gastroesophageal reflux disease (GERD in adults; however its role in pediatric groups remains unknown. This study aimed to investigate the significance of GEFV grading and the associations to multichannel intraluminal impedance and pH monitoring (MII-pH in children with GERD.A total of 48 children with GERD symptoms who received esophagogastroduodenoscopy and MII-pH monitoring were enrolled. The degree of GEFV was graded from I to IV according to the Hill classification, and classified into two groups: normal GEFV (Hill grades I and II, and abnormal GEFV (Hill grades III and VI. Endoscopic findings and MII-pH monitoring were analyzed among the groups.Thirty-six patients had normal GEFV while 12 had abnormal GEFV. The presence of erosive esophagitis was significantly more common in the patients with abnormal GEFV (p = 0.037, OR 9.84, 95% CI 1.15-84.42. Pathological acidic gastroesophageal reflux (GER determined by MII-pH was more prevalent in the patients with loosened GEFV geometry (p = 0.01, OR 7.0, 95% CI 1.67-27.38. There were significant positive correlations between GEFV Hill grading I to IV and the severity of erosive esophagitis (r = 0.49, p<0.001, percentage of supine acid reflux (r = 0.37, p = 0.009, percentage of total acid reflux (r = 0.3284, p = 0.023, and DeMeester score (r = 0.36, p = 0.01 detected by pH monitoring. In the impedance study, GEFV Hill grading also positively correlated to median number of acid reflux events (r = 0.3015, p = 0.037.GEFV dysfunction highly associated with acid GER and severe erosive esophagitis. An abnormal GEFV is a sign of acid GER in children.

  6. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  7. Serum magnesium, phosphorus, and calcium levels and subclinical calcific aortic valve disease: A population-based study.

    Science.gov (United States)

    Hisamatsu, Takashi; Miura, Katsuyuki; Fujiyoshi, Akira; Kadota, Aya; Miyagawa, Naoko; Satoh, Atsushi; Zaid, Maryam; Yamamoto, Takashi; Horie, Minoru; Ueshima, Hirotsugu

    2018-06-01

    Calcific aortic valve disease (CAVD) is the most common valve disease. Although micronutrients are known to contribute to cardiovascular disease, the relationship with CAVD remains poorly evaluated. We examined the association of serum levels of magnesium, phosphorus, and calcium with prevalence, incidence, and progression of aortic valve calcification (AVC). We conducted a prospective study in a population-based sample of Japanese men aged 40-79 years without known cardiovascular disease and chronic kidney disease at baseline, and quantified AVC from serial computed tomographic images with the Agatston method. Of 938 participants at baseline (mean age, 63.7 ± 9.9 years), AVC prevalence was observed in 173 (18.4%). Of 596 participants without baseline AVC at follow-up (median duration, 5.1 years), AVC incidence was observed in 138 (23.2%). After adjustment for demographics, behaviors and cardiovascular risk factors, relative risks (95% confidence intervals) in the highest versus lowest categories of serum magnesium, phosphorus, and calcium were 0.62 (0.44-0.86), 1.45 (1.02-2.04), and 1.43 (0.95-2.15), respectively, for AVC prevalence and 0.62 (0.42-0.92), 1.93 (1.28-2.91), and 1.09 (0.77-1.55), respectively, for AVC incidence. Their linear trends of serum magnesium and phosphorus were also all statistically significant. Of 131 participants with baseline AVC, there was no association of any serum micronutrients with AVC progression. Serum magnesium was inversely associated, while serum phosphorus was positively associated with AVC prevalence and incidence, suggesting that these serum micronutrients may be potential candidates for risk prediction or prevention of CAVD, and warranting further studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Chemical and structural composition study through transmission and reflection electron microscopy and X-ray microanalysis of damaged duramater cardiac valves

    International Nuclear Information System (INIS)

    Verginelli, G.; Didio, L.J.A.; Puig, L.B.; Allen, D.J.; Highinson, G.H.; Zerbini, E.J.

    1982-01-01

    Ten malfunctioning durameter aortic prosthesis, excised surgically after 44 to 54 months of implantation were studied through transmission and reflection electron microscopy and X-ray microanalysis. Duramater extracted at necropsy but not used for valve prosthesis and duramater aortic prosthesis not implanted in patients were used as controls. It was concluded that homologous duramater valves present subcellular changes following implantation, with degenerating and proliferating areas which could correspond either to normal adaptation or consequence of degeneration - rebuilding which begins with implantation; it is also emphazised the need for ultramicroscopic studies in evaluating biological tissues and establishing its applicability in cardiac surgery. (M.A.C.) [pt

  9. Correction of moderate secondary mitral regurgitation due to aortic valve disease: immediate results

    Directory of Open Access Journals (Sweden)

    В. М. Назаров

    2015-10-01

    Full Text Available To evaluate the impact of surgical strategy in concomitant mitral valve surgery or isolated aortic valve replacement (AVR in patients with moderate secondary mitral regurgitation (MR, 1 574 patients underwent AVR over a period from January 2003 to December 2011. 241 patients had secondary MR 2+ and constituted the study population. Patients were stratified into two groups, those without concomitant mitral valve surgery (Group A, n = 113 and with it (Group B, n = 128. It was found out that AVR plastic correction of MI reduces its recurrence during short-term follow-up but increases the intervention time leading to an insignificant rise in lethality. In patients with aortic stenosis the age exceeding 70 years and the presence of atrial fibrillation are found to be the most significant predictors of preservation of residual mitral regurgitation in the early postoperative period, while more indicative for patients with aortic insufficiency is the presence of tricuspid regurgitation grade 2 or higher.

  10. Idiopathic mitral valve disease in a patient presenting with Axenfeld-Rieger syndrome.

    Science.gov (United States)

    Antevil, Jared; Umakanthan, Ramanan; Leacche, Marzia; Brewer, Zachary; Solenkova, Natalia; Byrne, John G; Greelish, James P

    2009-05-01

    A 33-year-old, previously healthy male presented with respiratory distress and underwent intubation. A physical examination revealed a holosystolic murmur and pupillary abnormalities. Echocardiography revealed a flail anterior mitral valve leaflet with ruptured chordae and severe mitral regurgitation. The patient underwent urgent mitral valve replacement and tolerated the procedure well. The mitral valve leaflet was myxomatous and calcified -- an unusual find in such a patient. An ophthalmology consultation was obtained and the patient diagnosed with Axenfeld-Rieger syndrome, a disorder of the anterior ocular chamber that has been associated with cardiac malformations. The present case report adds to the body of literature which suggests a correlation between Axenfeld-Rieger syndrome and valvular abnormalities. Hence, it is believed prudent that patients with Axenfeld-Rieger syndrome should undergo echocardiographic screenings for valvular abnormalities.

  11. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  12. Valvular heart disease: assessment of valve morphology and quantification using MR

    Energy Technology Data Exchange (ETDEWEB)

    Schwitter, J. [Div. of Cardiology and Cardiovascular, MR Center, Univ. Hospital Zurich (Switzerland)

    2000-06-01

    For clinical evaluation and decision-making in patients with valvular heart disease, the diagnostic armamentarium expands steadily. This evolution makes it difficult to choose the most appropriate approach for a specific valvular lesion. It may also reflect our uncertainty of what are the findings that best predict clinical outcome of patients, e. g. after surgery. Accordingly, for each type of valvular lesion, some pathophysiological considerations are stated in order to derive the most important measures that would allow optimal guidance of patients. Based on these considerations the value of an MR study is discussed for each valvular lesion. Newest advances in MR technology allow for highly accurate measurements of regurgitant volumes and hence, MR may be the method of choice for a quantitative evaluation of regurgitant valves. For assessment of stenosis severity, measurement of transvalvular pressure gradient is an appropriate measure and MR may not confer benefits over echocardiography, provided the ultrasound window is adequate (and stroke volume is in the normal range). With respect to surgical treatment, valvular morphology is of pivotal importance, particularly for the mitral valve, and echocardiography still appears to be the first line method. Little data relate lesion severity and/or morphology to clinical outcome. Conversely, the extent of cardiac adaptation to pressure- and/or volume-overload, i. e. ventricular remodeling, is a strong predictor of outcome, and is therefore most important for final judgement of the patient. For assessment of left and right ventricular remodeling, echocardiography typically provides all the necessary information. However, in special cases with discrepant findings, with inadequate ultrasound window, or in the preoperative work-up, MR may provide important information regarding cardiac adaptation to valvular lesion. (orig.) [German] Das diagnostische Repertoire zur Evaluation von Klappenvitien ist in den letzten Jahren

  13. Endostatin and osteopontin are elevated in patients with both coronary artery disease and aortic valve calcification

    Directory of Open Access Journals (Sweden)

    Michael Sponder

    2015-12-01

    Conclusions: This is the first study showing an association of ES with AVC in CAD-patients independent from age, BMI and CAD-severity which seems to be of distinct interest when trying to understand the process of heart valve calcification. OPN also correlates with AVC-severity but is mostly dependent on the age of the patients.

  14. Arteriosclerotic changes in the myocardium, lung, and kidney in dogs with chronic congestive heart failure and myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Falk, Bo Torkel; Jönsson, Lennart; Olsen, Lisbeth Høier

    2006-01-01

    Background: The occurrence of small vessel arteriosclerosis in the myocardium, kidney, and lung in dogs with naturally occurring myxomatous mitral valve disease has not been previously investigated systematically. Methods: Twenty-one dogs with naturally occurring congestive heart failure and 21 age......-matched, sex-matched, and weight-matched control dogs underwent extensive pathological and histopathological examination. Morphometry and scoring of tissue sections were used to measure arterial narrowing and fibrosis in the myocardium, kidney, and lung; and intimal thickness and plaque formation in the aorta...... and pulmonary artery. Results: Dogs with congestive heart failure had significantly more arterial narrowing in the left ventricle (Pdogs. However...

  15. The Impact of Obesity on Postoperative Outcomes in Adults with Congenital Heart Disease Undergoing Pulmonary Valve Replacement.

    Science.gov (United States)

    Buelow, Matthew W; Earing, Michael G; Hill, Garick D; Cohen, Scott B; Bartz, Peter J; Tweddell, James S; Ginde, Salil

    2015-01-01

    The impact of obesity on surgical morbidity in adults with congenital heart disease is currently unknown. The aim of our study was to investigate the impact of obesity on postoperative outcomes in adults with congenital heart disease undergoing reoperation for pulmonary valve replacement. A retrospective analysis was performed assessing the influence of obesity on surgical outcomes. Obesity was defined as a body mass index ≥30 kg/m2. The mean body mass index of the cohort was 25.9 ± 6.9 kg/m2 . The cohort included 71 patients with 17 patients (24%) being obese. There was no postoperative mortality. Obese patients had a longer hospital length of stay (6.6 vs. 4.7 days; P obesity was independently associated with hospital length of stay >5 days (odds ratio [OR] = 5.2; 95% confidence interval [CI]: 1.5-18.2, P = .01) and with increased postoperative arrhythmias (OR = 4.2; 95% CI: 1.7-40, P Obesity is associated with increased morbidity in adults with congenital heart disease undergoing pulmonary valve replacement, including longer hospitalization and higher risk for postoperative arrhythmias. © 2015 Wiley Periodicals, Inc.

  16. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  17. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  18. The thoracic aortography by Gd-DTPA enhanced ultrafast cine MR imaging. Assessment of thoracic aortic dilatation in aging and in patients with hypertension and aortic valve disease

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiyoshi; Saito, Takayuki; Kikkawa, Nobutada; Haiyama, Toru

    1995-01-01

    To assess the morphology of thoracic aorta, we had a trial of Gd-DTPA enhanced ultrafast cine MR imaging on the thoracic aorta. This method was provided with high quality thoracic aortogram during 15-20 seconds. In patients without hypertension and aortic valve disease, dimensions of ascending aorta and aortic arch were significantly correlated with aging. In patients with hypertension, dimensions of ascending aorta and aortic arch were significantly dilated. In patients with aortic valve disease, thoracic aorta was diffusely enlarged, especially in ascending aorta. Gd-DTPA enhanced ultrafact cine MR imaging was useful to assess the thoracic aortic anatomy and diseases. (author)

  19. Cardiogenic shock as a complication of acute mitral valve regurgitation following posteromedial papillary muscle infarction in the absence of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Frati Giacomo

    2008-11-01

    Full Text Available Abstract A 48 year old man was transferred to our department with cardiogenic shock, pyrexia, a high white cell count and significant serum troponin T level. Clinical evaluation revealed severe mitral regurgitation secondary to a flail of both mitral valve leaflets. An emergency cardiac catheterisation did not reveal any significant coronary artery disease. Left ventricular angiogram and echocardiography demonstrated a good left ventricular function and massive mitral regurgitation. Blood cultures were negative for aerobics, anaerobics and fungi. The patient underwent emergency mitral valve replacement with a mechanical valve. Intraoperatively, the posteromedial papillary muscle was found to be ruptured. Histology of the papillary muscle revealed myocardial necrosis with no signs of infection. Cultures obtained from a mitral valve specimen were negative. The patient's recovery was uneventful and he was discharged on the 6th postoperative day.

  20. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  1. Catheterization Laboratory: Structural Heart Disease, Devices, and Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Fiorilli, Paul N; Anwaruddin, Saif; Zhou, Elizabeth; Shah, Ronak

    2017-12-01

    The cardiac catheterization laboratory is advancing medicine by performing procedures on patients who would usually require sternotomy and cardiopulmonary bypass. These procedures are done percutaneously, allowing them to be performed on patients considered inoperable. Patients have compromised cardiovascular function or advanced age. An anesthesiologist is essential for these procedures in case of hemodynamic compromise. Interventionalists are becoming more familiar with transcatheter aortic valve replacement and the device has become smaller, both contributing to less complications. Left atrial occlusion and the endovascular edge-to-edge mitral valve repair devices were approved. Although these devices require general anesthesia, an invasive surgery and cardiopulmonary bypass machine are not necessary for deployment. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Learning discriminative distance functions for valve retrieval and improved decision support in valvular heart disease

    Science.gov (United States)

    Voigt, Ingmar; Vitanovski, Dime; Ionasec, Razvan I.; Tsymal, Alexey; Georgescu, Bogdan; Zhou, Shaohua K.; Huber, Martin; Navab, Nassir; Hornegger, Joachim; Comaniciu, Dorin

    2010-03-01

    Disorders of the heart valves constitute a considerable health problem and often require surgical intervention. Recently various approaches were published seeking to overcome the shortcomings of current clinical practice,that still relies on manually performed measurements for performance assessment. Clinical decisions are still based on generic information from clinical guidelines and publications and personal experience of clinicians. We present a framework for retrieval and decision support using learning based discriminative distance functions and visualization of patient similarity with relative neighborhood graphsbased on shape and derived features. We considered two learning based techniques, namely learning from equivalence constraints and the intrinsic Random Forest distance. The generic approach enables for learning arbitrary user-defined concepts of similarity depending on the application. This is demonstrated with the proposed applications, including automated diagnosis and interventional suitability classification, where classification rates of up to 88.9% and 85.9% could be observed on a set of valve models from 288 and 102 patients respectively.

  3. Management of tricuspid valve regurgitation: Position statement of the European Society of Cardiology Working Groups of Cardiovascular Surgery and Valvular Heart Disease.

    Science.gov (United States)

    Antunes, Manuel J; Rodríguez-Palomares, José; Prendergast, Bernard; De Bonis, Michele; Rosenhek, Raphael; Al-Attar, Nawwar; Barili, Fabio; Casselman, Filip; Folliguet, Thierry; Iung, Bernard; Lancellotti, Patrizio; Muneretto, Claudio; Obadia, Jean-François; Pierard, Luc; Suwalski, Piotr; Zamorano, Pepe

    2017-12-01

    Tricuspid regurgitation (TR) is a very frequent manifestation of valvular heart disease. It may be due to the primary involvement of the valve or secondary to pulmonary hypertension or to the left-sided heart valve disease (most commonly rheumatic and involving the mitral valve). The pathophysiology of secondary TR is complex and is intrinsically connected to the anatomy and function of the right ventricle. A systematic multimodality approach to diagnosis and assessment (based not only on the severity of the TR but also on the assessment of annular size, RV function and degree of pulmonary hypertension) is, therefore, essential. Once considered non-important, treatment of secondary TR is currently viewed as an essential concomitant procedure at the time of mitral (and, less frequently, aortic valve) surgery. Although the indications for surgical management of severe TR are now generally accepted (Class I), controversy persists concerning the role of intervention for moderate TR. However, there is a trend for intervention in this setting, especially at the time of surgery for left-sided heart valve disease and/or in patients with significant tricuspid annular dilatation (Class IIa). Currently, surgery remains the best approach for the interventional treatment of TR. Percutaneous tricuspid valve intervention (both repair and replacement) is still in its infancy but may become a reliable option in future, especially for high-risk patients with isolated primary TR or with secondary TR related to advanced left-sided heart valve disease. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.

    Science.gov (United States)

    Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi

    2013-09-10

    Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.

  5. A Systematic Review of Infective Endocarditis in Patients With Bovine Jugular Vein Valves Compared With Other Valve Types.

    Science.gov (United States)

    Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C

    2017-07-24

    The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  7. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  8. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  9. Increased serum C-reactive protein concentrations in dogs with congestive heart failure due to myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Reimann, M. J.; Ljungvall, I.; Hillstrom, A.

    2016-01-01

    Cardiovascular disease in humans and dogs is associated with mildly increased circulating concentrations of C-reactive protein (CRP). Few studies have evaluated associations between circulating CRP and canine myxomatous mitral valve disease (MMVD) and the results reported have been divergent....... The aim of this study was to investigate whether serum concentrations of CRP, determined using a novel automated canine-specific high -sensitivity CRP assay (Gentian hsCRP), were associated with severity of MMVD and selected clinical variables in dogs. The study included 188 client-owned dogs...... with different severities of MMVD. Dogs were classified based on ACVIM consensus statement guidelines (group A, n = 58; group BI, n = 56; group B2, n = 38; group C, n = 36). Data were analysed using descriptive statistics and multiple regression analysis. Dogs with congestive heart failure (CHF; group C) had...

  10. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  11. Long-Term Health Benefit of Transcatheter Aortic Valve Replacement in Patients With Chronic Lung Disease.

    Science.gov (United States)

    Crestanello, Juan A; Popma, Jeffrey J; Adams, David H; Deeb, G Michael; Mumtaz, Mubashir; George, Barry; Huang, Jian; Reardon, Michael J

    2017-11-27

    This study sought to characterize the long-term effect of chronic lung disease (CLD) on mortality, clinical outcomes, quality of life, and health benefits after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis. The long-term effect of CLD after TAVR is unknown. Prevalence and severity of CLD was determined at baseline in high- and extreme-risk patients with aortic stenosis from the CoreValve US Pivotal Trial. Clinical outcomes and health status were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OS). A favorable health benefit was defined as alive with a KCCQ-OS ≥60 and stability (CLD was present in 55% (20% mild, 13% moderate, 22% severe) of the 1,030 patients studied. All-cause mortality was higher in patients with moderate and severe CLD at 1 year (19.6% mild, 28.1% moderate, 26.9% severe CLD vs. 19.2% non-CLD; p = 0.030) and 3 years (44.8% mild, 53.0% moderate, 51.9% severe vs. 37.7% non-CLD; p CLD at 1 and 3 years. All patients had a nearly 20-point improvement in KCCQ-OS at 1 and 3 years. However, only 43.3% of patients with CLD had a favorable health benefit at 1 year and 22.5% at 3 years. Moderate and severe CLD increases 1- and 3-year mortality after TAVR. Although functional status and quality of life were improved in CLD at 1 and 3 years after TAVR, a favorable health benefit was only achieved in selected patients. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. A comparison of the histopathologic pattern of the left atrium in canine dilated cardiomyopathy and chronic mitral valve disease.

    Science.gov (United States)

    Janus, Izabela; Noszczyk-Nowak, Agnieszka; Nowak, Marcin; Ciaputa, Rafał; Kandefer-Gola, Małgorzata; Pasławska, Urszula

    2016-01-05

    Dilated cardiomyopathy (DCM) and chronic mitral valve disease (CMVD) in dogs are associated with heart chamber enlargement, also of the left atrium. DCM is often accompanied by rhythm disturbances (mainly atrial fibrillation or ventricular arrhythmias). In CMVD, arrhythmias are observed less frequently. It is still unclear whether left atrial enlargement in these diseases results from volume overload or if it is also connected with other factors (e.g. rhythm disturbances). This study was conducted on the left atrial myocardial specimens from 31 dogs, including those from 16 dogs with clinically diagnosed DCM and 15 dogs with CMVD. After fixation and staining (using haematoxylin-eosin and Masson-Goldner trichrome stain), the specimens underwent evaluation. Parenchymal changes (fibrosis, fatty infiltration, and vessel narrowing), degenerative changes (loss of striation, changes in cardiomyocyte structure, and abnormal cell nuclei) and the presence of inflammatory infiltrates were assessed. More interstitial fibrosis (median 4 vs. 2.5 grid fields; p < 0.05) and less perivascular fibrosis (median score 1 vs. 2; p < 0.05) was observed in the DCM group compared to the CMVD group. Moreover, less distinct vessel narrowing was observed in the DCM group than in the CMVD group (median lumen area ratio 0.3 vs. 0.26 respectively; p < 0.05). Dogs with DCM showed more strongly defined degenerative changes than the CMVD dogs (median nuclei enlargement score 3 vs. 1, median loss of striation score 3 vs. 2 and median structural alterations score 3 vs. 2, respectively; p < 0.05). The obtained results indicate a different nature of changes occurring in the left atrial myocardium of dogs with DCM compared to dogs with mitral valve disease, including differences in vessel narrowing, cardiomyocyte degeneration and in the distribution of connective tissue.

  13. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  14. Nonalcoholic fatty liver disease is associated with aortic valve sclerosis in patients with type 2 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Stefano Bonapace

    Full Text Available BACKGROUND: Recent epidemiological data suggest that non-alcoholic fatty liver disease (NAFLD is closely associated with aortic valve sclerosis (AVS, an emerging risk factor for adverse cardiovascular outcomes, in nondiabetic and type 2 diabetic individuals. To date, nobody has investigated the association between NAFLD and AVS in people with type 2 diabetes, a group of individuals in which the prevalence of these two diseases is high. METHODS AND RESULTS: We recruited 180 consecutive type 2 diabetic patients without ischemic heart disease, valvular heart disease, hepatic diseases or excessive alcohol consumption. NAFLD was diagnosed by liver ultrasonography whereas AVS was determined by conventional echocardiography in all participants. In the whole sample, 120 (66.7% patients had NAFLD and 53 (29.4% had AVS. No patients had aortic stenosis. NAFLD was strongly associated with an increased risk of prevalent AVS (odds ratio [OR] 2.79, 95% CI 1.3-6.1, p<0.01. Adjustments for age, sex, duration of diabetes, diabetes treatment, body mass index, smoking, alcohol consumption, hypertension, dyslipidemia, hemoglobin A1c and estimated glomerular filtration rate did not attenuate the strong association between NAFLD and risk of prevalent AVS (adjusted-OR 3.04, 95% CI 1.3-7.3, p = 0.01. CONCLUSIONS: Our results provide the first demonstration of a positive and independent association between NAFLD and AVS in patients with type 2 diabetes mellitus.

  15. An experimental investigation on reverse-cycle defrosting performance for an air source heat pump using an electronic expansion valve

    International Nuclear Information System (INIS)

    Qu, Minglu; Xia, Liang; Deng, Shiming; Jiang, Yiqiang

    2012-01-01

    Highlights: ► We experimentally studied the defrost performance under two EEV control strategies. ► The two EEV control strategies were fully open and controlled by a DS controller. ► When the EEV was under the DS controller, higher defrosting efficiency was obtained. -- Abstract: When an air source heat pump (ASHP) operates in heating mode, frost can be accumulated on the surface of its finned outdoor coil. Frosting deteriorates the operation and energy efficiency of the ASHP and periodic defrosting becomes necessary. Currently the most widely used standard defrosting method for ASHPs is reverse cycle defrost. On the other hand, electronic expansion valves (EEVs) are commonly used in heat pump/refrigeration systems, including ASHP units, as throttle regulators of refrigerant flow. This paper reports on an experimental investigation of the performance of a reverse cycle defrost operation for a 6.5 kW experimental heating capacity residential ASHP whose outdoor coil had four-parallel refrigerant circuits, and with an EEV as the refrigerant flow throttle regulator. The detailed descriptions of the experimental ASHP unit and the experimental procedures of ASHP are firstly presented. This is followed by reporting the comparative experiments of two control strategies for the EEV to investigate their effects on defrosting performance: the EEV being fully open and the EEV being regulated by a degree of refrigerant superheat (DS) controller. Experimental results revealed that when the EEV was regulated by the DS controller during defrosting, a higher defrosting efficiency and less heat wastage would be resulted in.

  16. R-R interval variations influence the degree of mitral regurgitation in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Reimann, M. J.; Moller, J. E.; Haggstrom, J.

    2014-01-01

    of congestive heart failure due to MMVD. The severity of MR was evaluated in apical four-chamber view using colour Doppler flow mapping (maximum % of the left atrium area) and colour Doppler M-mode (duration in ms). The influence of the ratio between present and preceding R-R interval on MR severity......Mitral regurgitation (MR) due to myxomatous mitral valve disease (MMVD) is a frequent finding in Cavalier King Charles Spaniels (CKCSs). Sinus arrhythmia and atrial premature complexes leading to R-R interval variations occur in dogs. The aim of the study was to evaluate whether the duration...... of the RR interval immediately influences the degree of MR assessed by echocardiography in dogs. Clinical examination including echocardiography was performed in 103 privately-owned dogs: 16 control Beagles, 70 CKCSs with different degree of MR and 17 dogs of different breeds with clinical signs...

  17. Age-related changes in aortic 3D blood flow velocities and wall shear stress: Implications for the identification of altered hemodynamics in patients with aortic valve disease

    NARCIS (Netherlands)

    van Ooij, Pim; Garcia, Julio; Potters, Wouter V.; Malaisrie, S. Chris; Collins, Jeremy D.; Carr, James C.; Markl, Michael; Barker, Alex J.

    2016-01-01

    To investigate age-related changes in peak systolic aortic 3D velocity and wall shear stress (WSS) in healthy controls and to investigate the importance of age-matching for 3D mapping of abnormal aortic hemodynamics in bicuspid aortic valve disease (BAV). 4D flow MRI (fields strengths = 1.5-3T;

  18. Reliability and construct validity of the Instrument to Measure the Impact of Valve Heart Disease on the Patient's Daily Life.

    Science.gov (United States)

    Anjos, Daniela Brianne Martins Dos; Rodrigues, Roberta Cunha Matheus; Padilha, Kátia Melissa; Pedrosa, Rafaela Batista Dos Santos; Gallani, Maria Cecília Bueno Jayme

    2016-12-19

    evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease. avaliar a praticabilidade, aceitabilidade e os efeitos teto e chão, estimar a confiabilidade e verificar a validade de construto convergente do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata em pacientes com valvopatia mitral e/ou aórtica. dados foram obtidos junto a 86 pacientes valvopatas por meio de três etapas: uma entrevista presencial para caracterização sociodemográfica e clínica e as duas outras realizadas por meio de contato telefônico para as aplicações do instrumento (Teste e teste de repetição). quanto à praticabilidade e aceitabilidade, o instrumento foi aplicado com tempo m

  19. Triple-orifice valve repair in severe Barlow disease with multiple-jet mitral regurgitation: report of mid-term experience.

    Science.gov (United States)

    Fucci, Carlo; Faggiano, Pompilio; Nardi, Matilde; D'Aloia, Antonio; Coletti, Giuseppe; De Cicco, Giuseppe; Latini, Leonardo; Vizzardi, Enrico; Lorusso, Roberto

    2013-09-10

    Barlow disease represents a surgical challenge for mitral valve repair (MR) in the presence of mitral insufficiency (MI) with multiple regurgitant jets. We hereby present our mid-term experience using a modified edge-to-edge technique to address this peculiar MI. From March 2003 till December 2010, 25 consecutive patients (mean age 54 ± 7 years, 14 males) affected by severe Barlow disease with multiple regurgitant jets were submitted to MR. Preoperative transesophageal echo (TEE) in all the cases showed at least 2 regurgitant jets, involving one or both leaflets in more than one segment. In all the patients, a triple orifice valve (TOV) repair with annuloplasty was performed. Intra-operative TEE and postoperative transthoracic echocardiography (TTE) were carried out to evaluate results of the TOV repair. There was no in-hospital death and one late death (non-cardiac related). At intra-operative TEE, the three orifices showed a mean total valve area of 2.9 ± 0.1cm(2) (range 2.5-3.3 cm(2)) with no residual regurgitation (2 cases of trivial MI) and no sign of valve stenosis (mean transvalvular gradient 4.6 ± 1.5 mmHg). At follow up (mean 38 ± 22 months), TTE showed favourable MR and no recurrence of significant MI (6 cases of trivial and 1 of mild MI). Stress TTE was performed in 5 cases showing persistent effective valve function (2 cases of trivial MI at peak exercise). All the patients showed significant NYHA functional class improvement. This report indicates that the TOV technique is effective in correcting complex Barlow mitral valves with multiple jets. Further studies are required to confirm long-term applicability and durability in more numerous clinical cases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Heart valve surgery - discharge

    Science.gov (United States)

    ... ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  1. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  2. ESC Working Group on Valvular Heart Disease position paper--heart valve clinics: organization, structure, and experiences.

    Science.gov (United States)

    Lancellotti, Patrizio; Rosenhek, Raphael; Pibarot, Philippe; Iung, Bernard; Otto, Catherine M; Tornos, Pilar; Donal, Erwan; Prendergast, Bernard; Magne, Julien; La Canna, Giovanni; Piérard, Luc A; Maurer, Gerald

    2013-06-01

    With an increasing prevalence of patients with valvular heart disease (VHD), a dedicated management approach is needed. The challenges encountered are manifold and include appropriate diagnosis and quantification of valve lesion, organization of adequate follow-up, and making the right management decisions, in particular with regard to the timing and choice of interventions. Data from the Euro Heart Survey have shown a substantial discrepancy between guidelines and clinical practice in the field of VHD and many patients are denied surgery despite having clear indications. The concept of heart valve clinics (HVCs) is increasingly recognized as the way to proceed. At the same time, very few centres have developed such expertise, indicating that specific recommendations for the initial development and subsequent operating requirements of an HVC are needed. The aim of this position paper is to provide insights into the rationale, organization, structure, and expertise needed to establish and operate an HVC. Although the main goal is to improve the clinical management of patients with VHD, the impact of HVCs on education is of particular importance: larger patient volumes foster the required expertise among more senior physicians but are also fundamental for training new cardiologists, medical students, and nurses. Additional benefits arise from research opportunities resulting from such an organized structure and the delivery of standardized care protocols. The growing volume of patients with VHD, their changing characteristics, and the growing technological opportunities of refined diagnosis and treatment in addition to the potential dismal prognosis if overlooked mandate specialized evaluation and care by dedicated physicians working in a specialized environment that is called the HVC.

  3. Engineering a 3D-Bioprinted Model of Human Heart Valve Disease Using Nanoindentation-Based Biomechanics

    Directory of Open Access Journals (Sweden)

    Dewy C. van der Valk

    2018-05-01

    Full Text Available In calcific aortic valve disease (CAVD, microcalcifications originating from nanoscale calcifying vesicles disrupt the aortic valve (AV leaflets, which consist of three (biomechanically distinct layers: the fibrosa, spongiosa, and ventricularis. CAVD has no pharmacotherapy and lacks in vitro models as a result of complex valvular biomechanical features surrounding resident mechanosensitive valvular interstitial cells (VICs. We measured layer-specific mechanical properties of the human AV and engineered a three-dimensional (3D-bioprinted CAVD model that recapitulates leaflet layer biomechanics for the first time. Human AV leaflet layers were separated by microdissection, and nanoindentation determined layer-specific Young’s moduli. Methacrylated gelatin (GelMA/methacrylated hyaluronic acid (HAMA hydrogels were tuned to duplicate layer-specific mechanical characteristics, followed by 3D-printing with encapsulated human VICs. Hydrogels were exposed to osteogenic media (OM to induce microcalcification, and VIC pathogenesis was assessed by near infrared or immunofluorescence microscopy. Median Young’s moduli of the AV layers were 37.1, 15.4, and 26.9 kPa (fibrosa/spongiosa/ventricularis, respectively. The fibrosa and spongiosa Young’s moduli matched the 3D 5% GelMa/1% HAMA UV-crosslinked hydrogels. OM stimulation of VIC-laden bioprinted hydrogels induced microcalcification without apoptosis. We report the first layer-specific measurements of human AV moduli and a novel 3D-bioprinted CAVD model that potentiates microcalcification by mimicking the native AV mechanical environment. This work sheds light on valvular mechanobiology and could facilitate high-throughput drug-screening in CAVD.

  4. Cardiac valve disease: an unreported feature in Ehlers Danlos syndrome arthrocalasia type?

    Directory of Open Access Journals (Sweden)

    Melis Daniela

    2012-11-01

    Full Text Available Abstract Ehlers Danlos syndrome (EDS athrocalasia type (type VII, is characterized by joint hypermobility, skin hyperextensibility and tissue fragility. No heart involvement has been reported. Two forms have been described: type VII A and VII B. The abnormally processed collagen α2(I and the skipping of the exon 6 in COL1A2 gene are typically detected in EDS type VII B. We describe a seven-year old female, with a phenotype consistent with EDS type VII B and a diagnosis further confirmed by biochemical and molecular analyses. Cardiac ultrasound showed normal data in the first year of life. When she was 5 years old, the patient developed mitral valve regurgitation, and aortic and tricuspidal insufficiency at 7 years of age. To our knowledge, this is the first report of cardiac valvular involvement in EDS VII B. This feature probably has been underreported for the limited follow-up of the patients. Echocardiography might be warranted in the clinical assessment of EDS VII patients.

  5. Analysis of cardiac energy metabolism in valve disease using 31P-MR-spectroscopy

    International Nuclear Information System (INIS)

    Beer, M.; Viehrig, M.; Seyfarth, T.; Sandstede, J.; Lipke, C.; Pabst, T.; Kenn, W.; Hahn, D.; Harre, K.; Horn, M.; Neubauer, S.; Landschuetz, W.; Kienlin, M. von

    2000-01-01

    Patients and methods: 10 healthy volunteers and 10 patients with aortic stenosis (pressure gradients >60 mmHg) were included. For assessment of energy metabolism, 31 P-MR spectra were obtained with a double oblique 3D-CSI technique (voxel size 25 cm 3 ). In 5 of 10 patients, follow-up examination was performed 3 months after surgical valve replacement (SVR). Left ventricular (LV) function was analyzed by cine MRI. Results: Before SVR the myocardial phosphocreatine to adenosinetriphosphate (PCr-ATP) ratio was significantly (p=0.0002) reduced to 0.80±0.25 in patients compared to 1.65±0.21 in volunteers. 3 months after SVR, LV mass had significantly (p=0.04) decreased from 238±33 g to 206±47 g. At the same time a significant (p=0.04) increase of the PCr-ATP ratio from 0.80±0.25 to 1.28±0.22 was observed. A slight, but not significant, reduction of the phosphodiester ATP ratio was observed before SVR, with a trend towards normalization after SVR. (orig.) [de

  6. Enhancing roll stability of heavy vehicle by LQR active anti-roll bar control using electronic servo-valve hydraulic actuators

    Science.gov (United States)

    Vu, Van Tan; Sename, Olivier; Dugard, Luc; Gaspar, Peter

    2017-09-01

    Rollover of heavy vehicle is an important road safety problem world-wide. Although rollovers are relatively rare events, they are usually deadly accidents when they occur. The roll stability loss is the main cause of rollover accidents in which heavy vehicles are involved. In order to improve the roll stability, most of modern heavy vehicles are equipped with passive anti-roll bars to reduce roll motion during cornering or riding on uneven roads. However these may be not sufficient to overcome critical situations. This paper introduces the active anti-roll bars made of four electronic servo-valve hydraulic actuators, which are modelled and integrated in a yaw-roll model of a single unit heavy vehicle. The control signal is the current entering the electronic servo-valve and the output is the force generated by the hydraulic actuator. The active control design is achieved solving a linear optimal control problem based on the linear quadratic regulator (LQR) approach. A comparison of several LQR controllers is provided to allow for tackling the considered multi-objective problems. Simulation results in frequency and time domains show that the use of two active anti-roll bars (front and rear axles) drastically improves the roll stability of the single unit heavy vehicle compared with the passive anti-roll bar.

  7. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  8. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  9. Dynamic and quantitative evaluation of degenerative mitral valve disease: a dedicated framework based on cardiac magnetic resonance imaging.

    Science.gov (United States)

    Sturla, Francesco; Onorati, Francesco; Puppini, Giovanni; Pappalardo, Omar A; Selmi, Matteo; Votta, Emiliano; Faggian, Giuseppe; Redaelli, Alberto

    2017-04-01

    Accurate quantification of mitral valve (MV) morphology and dynamic behavior over the cardiac cycle is crucial to understand the mechanisms of degenerative MV dysfunction and to guide the surgical intervention. Cardiac magnetic resonance (CMR) imaging has progressively been adopted to evaluate MV pathophysiology, although a dedicated framework is required to perform a quantitative assessment of the functional MV anatomy. We investigated MV dynamic behavior in subjects with normal MV anatomy (n=10) and patients referred to surgery due to degenerative MV prolapse, classified as fibro-elastic deficiency (FED, n=9) and Barlow's disease (BD, n=10). A CMR-dedicated framework was adopted to evaluate prolapse height and volume and quantitatively assess valvular morphology and papillary muscles (PAPs) function over the cardiac cycle. Multiple comparison was used to investigate the hallmarks associated to MV degenerative prolapse and evaluate the feasibility of anatomical and functional distinction between FED and BD phenotypes. On average, annular dimensions were significantly (Pframework allows for the quantitative and dynamic evaluation of MV apparatus, with quantifiable annular alterations representing the primary hallmark of severe MV degeneration. This may aid surgeons in the evaluation of the severity of MV dysfunction and the selection of the appropriate MV treatment.

  10. Diagnostic Value of Selected Echocardiographic Variables to Identify Pulmonary Hypertension in Dogs with Myxomatous Mitral Valve Disease.

    Science.gov (United States)

    Tidholm, A; Höglund, K; Häggström, J; Ljungvall, I

    2015-01-01

    Pulmonary hypertension (PH) is commonly associated with myxomatous mitral valve disease (MMVD). Because dogs with PH present without measureable tricuspid regurgitation (TR), it would be useful to investigate echocardiographic variables that can identify PH. To investigate associations between estimated systolic TR pressure gradient (TRPG) and dog characteristics and selected echocardiographic variables. 156 privately owned dogs. Prospective observational study comparing the estimations of TRPG with dog characteristics and selected echocardiographic variables in dogs with MMVD and measureable TR. Tricuspid regurgitation pressure gradient was significantly (P modeled as linear variables LA/Ao (P modeled as second order polynomial variables: AT/DT (P = .0039) and LVIDDn (P value for the final model was 0.45 and receiver operating characteristic curve analysis suggested the model's performance to predict PH, defined as 36, 45, and 55 mmHg as fair (area under the curve [AUC] = 0.80), good (AUC = 0.86), and excellent (AUC = 0.92), respectively. In dogs with MMVD, the presence of PH might be suspected with the combination of decreased PA AT/DT, increased RVIDDn and LA/Ao, and a small or great LVIDDn. Copyright © 2015 The Authors Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  11. INFLUENCE OF GRADED AEROBIC EXERCISE ON QUALITY OF LIFE IN POST SURGICAL MITRAL VALVE DISEASE INDIVIDUAL A PROSPECTIVE RANDOMIZED OPEN LABEL STUDY

    Directory of Open Access Journals (Sweden)

    Shanthi C

    2016-10-01

    Full Text Available Background: Post surgical mitral valve disease individual focus their cardiac rehabilitation training on two major goal that is to improve cardiac output response exercises and place an important role in determining exercise tolerance and to improve quality of life. Cardiac rehabilitation programs involve prescribed exercise and education however various other method are being used to improve quality of life. But our study to find out the effectiveness of graded aerobic exercise protocol on ejection fraction and quality of life in post surgical mitral valve disease individuals. Methods: The study design was open label studies total of 100 post surgical mitral valve disease individuals patients from the age group of 20-60 years were recruited from SVIMS hospital. They were randomly divided into two groups. Group I underwent a twelve week structured graded individually tailored exercises. The group II received only none graded (not individualized exercise training. The ejection fraction and quality of life was measured before and after 12 weeks of exercise training for two groups. Results: Repeated measures ANOVA was used to compare mean values of continuous variables between baseline and at the time of discharge and three months after surgery for each parameter. Comparison of means between groups was done by the unpaired student t test. Mean age of the subjects was 40.18±10.29. There was a significant increase in the ejection fraction in the group I(61.34±2.49 to 64.4±3.31 compared to with the group II (61.06±2.51. to 61.62 ±2.37. QOL had improved in group I than group II at p<0.05. Conclusion: A 12 week structured graded aerobic exercise training significantly improved ejection fraction and quality of life in post surgical mitral valve disease individuals.

  12. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    Science.gov (United States)

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  13. Quantification of Mitral Regurgitation in Anatolian Shepherd Dogs with Asymptomatic Degenerative Mitral Valve Disease

    Directory of Open Access Journals (Sweden)

    Kursad Turgut1*, Yilmaz Koc2, Hasan Guzelbektes1,3, Amir Naseri1, Mehmet Ege Ince1 and Ismail Sen1

    2016-11-01

    Full Text Available Degenerative mitral valvular disease (DMVD is the most frequent cardiac disease, causing mitral regurgitation (MR in dogs. The purpose of this study was to compare the ratio of the regurgitant jet area (RJA to the left atrial area (LAA (RJA/LAA with subtracting method to quantify regurgitant volume (RegV and regurgitant fraction (RF in asymptomatic Anatolian Shepherd Dogs (ASHs with DMVD. Thirty-eight ASHs with DMVD were used as experimental group. The control group consisted of 35 healthy ASHs. In 38 ASHs with DMVD (20 B1 dogs and 18 B2 dogs, the severity of MR was assessed by RJA/LAA and subtraction method. No differences were noted between the assays measuring the severity of MR by χ2 analysis. The observed agreement between the assays was 81% for RJA/LAA vs RegV and was 73% for RJA/LAA vs RF, and the kappa statistic values for RJA/LAA vs RegV and for RJA/LAA vs RF were 0.63 (substantial agreement and 0.50 (moderate agreement, respectively. Our results indicate that each quantification method was valuable to estimate the acuteness of the disease in ASHs with MR and all were in good accordance with the echocardiographic heart size and N-terminal Pro-Brain Natriuretic Peptide (NT-proBNP measurements. Therefore, the each of these non-invasive methods may be functional to serially estimate the acuteness of MR in DMVD in order to monitor the progression of disease. Future studies have to evaluate, if these will be useful to anticipate the risk or time of decompensation in asymptomatic dogs.

  14. Intravenous administration of puppy deciduous teeth stem cells in degenerative valve disease

    Directory of Open Access Journals (Sweden)

    Soontaree Petchdee

    2016-12-01

    Full Text Available Aim: The objective of this study is to investigate the improvement of heart function in dogs with chronic valvular heart disease after puppy deciduous teeth stem cells (pDSCs administration. Materials and Methods: 20 client-owned dogs with degenerative valvular heart disease underwent multiple intravenous injections of allogeneic pDSCs. Dogs were randomly assigned to two groups: (i Control group (n=10 with standard treatment for heart failure and (ii group with standard treatment and multiple administrations of pDSCs (n=10. Electrocardiography, complete transthoracic echocardiography, thoracic radiography, and blood pressure were recorded before and after pDSCs injections for 15, 30 and 60 days. Results: Post pDSCs injection showed measurable improvement in left ventricular ejection fraction, American College of Veterinary Internal Medicine (ACVIM functional class significantly improved and improved quality of life scores were observed. In the control group, there were no significant enhancements in heart function or ACVIM class. Conclusions: This finding suggests that pDSCs could be a supplement for valvular heart disease treatment.

  15. Outcomes of patients with chronic lung disease and severe aortic stenosis treated with transcatheter versus surgical aortic valve replacement or standard therapy: insights from the PARTNER trial (placement of AoRTic TraNscathetER Valve).

    Science.gov (United States)

    Dvir, Danny; Waksman, Ron; Barbash, Israel M; Kodali, Susheel K; Svensson, Lars G; Tuzcu, E Murat; Xu, Ke; Minha, Sa'ar; Alu, Maria C; Szeto, Wilson Y; Thourani, Vinod H; Makkar, Raj; Kapadia, Samir; Satler, Lowell F; Webb, John G; Leon, Martin B; Pichard, Augusto D

    2014-01-28

    The study aimed to evaluate the impact of chronic lung disease (CLD) on outcomes of severe aortic stenosis patients across all treatment modalities. Outcomes of patients with CLD undergoing transcatheter aortic valve replacement (TAVR) have not been systematically examined. All patients who underwent TAVR in the PARTNER (Placement of AoRTic TraNscathetER Valve) trial, including the continued access registry (n = 2,553; 1,108 with CLD), were evaluated according to CLD clinical severity. Additionally, outcomes of CLD patients included in the randomization arms of the PARTNER trial were compared: Cohort A patients (high-risk operable) treated by either TAVR (n = 149) or surgical aortic valve replacement (SAVR); (n = 138); and Cohort B patients (inoperable) treated by either TAVR (n = 72) or standard therapy only (n = 95). Among all TAVR-treated patients, at 1-year follow-up, patients with CLD had higher mortality than those without it (23.4% vs. 19.6%, p = 0.02). Baseline characteristics of CLD patients who underwent TAVR were similar to respective controls. In Cohort A, 2-year all-cause death rates were similar (TAVR 35.2% and SAVR 33.6%, p = 0.92), whereas in Cohort B, the death rate was lower after TAVR (52.0% vs. 69.6% after standard therapy only, p = 0.04). Independent predictors for mortality in CLD patients undergoing TAVR included poor mobility (6-min walk test CLD patients undergoing TAVR have worse outcomes than patients without CLD, TAVR is better in these patients than standard therapy and is similar to SAVR. Although patients with CLD undergoing TAVR had worse outcomes than patients without CLD, TAVR performed better in these patients than standard therapy and was similar to SAVR. However, CLD patients who were either poorly mobile or oxygen-dependent had poor outcomes. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  16. Circulating cytokine concentrations in dogs with different degrees of myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Zois, Nora Elisabeth; Moesgaard, Sophia Gry; Kjelgaard-Hansen, Mads

    2012-01-01

    , IL-15, IL-18, keratinocyte-derived chemokine, interferon-c-induced protein and monocyte chemoattractant protein-1 (MCP-1) were measured using a canine-specific multiplex immunoassay. CHF dogs had significantly higher MCP-1 concentrations than dogs with no or minimal MR. Among the CKCS, IL-2 and IL-7...... decreased with increasing left atrial size and IL-7 also decreased with increasing MR. IL-8 decreased with increasing left ventricular end-systolic internal dimensions. MCP-1 was increased in CHF dogs compared to healthy control dogs and IL-2, IL-7 and IL-8 decreased with increasing indices of disease...

  17. Veterinary Medicine and Multi-Omics Research for Future Nutrition Targets: Metabolomics and Transcriptomics of the Common Degenerative Mitral Valve Disease in Dogs.

    Science.gov (United States)

    Li, Qinghong; Freeman, Lisa M; Rush, John E; Huggins, Gordon S; Kennedy, Adam D; Labuda, Jeffrey A; Laflamme, Dorothy P; Hannah, Steven S

    2015-08-01

    Canine degenerative mitral valve disease (DMVD) is the most common form of heart disease in dogs. The objective of this study was to identify cellular and metabolic pathways that play a role in DMVD by performing metabolomics and transcriptomics analyses on serum and tissue (mitral valve and left ventricle) samples previously collected from dogs with DMVD or healthy hearts. Gas or liquid chromatography followed by mass spectrophotometry were used to identify metabolites in serum. Transcriptomics analysis of tissue samples was completed using RNA-seq, and selected targets were confirmed by RT-qPCR. Random Forest analysis was used to classify the metabolites that best predicted the presence of DMVD. Results identified 41 known and 13 unknown serum metabolites that were significantly different between healthy and DMVD dogs, representing alterations in fat and glucose energy metabolism, oxidative stress, and other pathways. The three metabolites with the greatest single effect in the Random Forest analysis were γ-glutamylmethionine, oxidized glutathione, and asymmetric dimethylarginine. Transcriptomics analysis identified 812 differentially expressed transcripts in left ventricle samples and 263 in mitral valve samples, representing changes in energy metabolism, antioxidant function, nitric oxide signaling, and extracellular matrix homeostasis pathways. Many of the identified alterations may benefit from nutritional or medical management. Our study provides evidence of the growing importance of integrative approaches in multi-omics research in veterinary and nutritional sciences.

  18. Left atrial volume and function in dogs with naturally occurring myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Höllmer, M.; Willesen, J. L.; Tolver, A.

    2017-01-01

    stroke volume increased, whereas LA reservoir and contractile function decreased with increasing disease severity. A maximal LA volume heart failure in dogs with chronic MMVD with a sensitivity of 96% and a specificity of 100......%. An active LA emptying fraction heart failure in dogs with chronic MMVD with a sensitivity of 77% and a specificity of 89% and a sensitivity of 82% and a specificity of 82%, respectively. CONCLUSION: Dogs with MMVD appear to have larger LA...... of cardiac compensation. Left atrial function in dogs with naturally occurring MMVD remains largely unexplored. The objective of this study was to evaluate LA volume and function in dogs with naturally occurring MMVD. ANIMALS: This prospective study included 205 client-owned dogs of different breeds, 114...

  19. Clinical information has low sensitivity for postmortem diagnosis of heart valve disease.

    Science.gov (United States)

    Coffey, Sean; Harper, Andrew R; Cairns, Benjamin J; Roberts, Ian Sd; Prendergast, Bernard D

    2017-07-01

    Accuracy of routinely collected information concerning cause of death is essential for public health and health systems planning. Since clinical examination has relatively low sensitivity for detection of valvular heart disease (VHD), mortality data based on clinical information alone might routinely underestimate the number of deaths due to VHD. We compared autopsy findings against premortem clinical information for 8198 consecutive adult postmortems (mean age 69.1 years, 61.3% men), performed in a single UK tertiary referral centre with on-site cardiac surgical facilities over a 10-year period (2004-2013) during which 21% of the adult population underwent postmortem examination. Following postmortem, VHD was the principal cause of death in 165 individuals (2.0%), a principal or contributory cause ('any cause') of death in 326 (4.0%) and an incidental (ie, non-causal) finding in a further 346 (4.2%). Clinical documentation of VHD before death was highly specific but relatively insensitive for postmortem identification of VHD as the principal (specificity 96.8%; 95% CI 96.4% to 97.2%; sensitivity 69.7%, 95% CI 62.1% to 76.6%) or any (specificity 98.1%; 95% CI 97.8% to 98.4%; sensitivity 68.4%, 95% CI 63.1% to 73.4%) cause of death. VHD (principally aortic stenosis, endocarditis and rheumatic heart disease) was newly noted at postmortem and listed as a cause of death in 142 individuals (1.7%). Clinical information recorded premortem is highly specific but relatively insensitive for the cause of death established at autopsy. Population-based mortality statistics that depend on premortem clinical information are likely to routinely underestimate the mortality burden of VHD. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.

    Science.gov (United States)

    Kistan, D; Booysen, M; Alexander, G; Madiba, T E

    2017-06-01

    Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients

  1. Mitral valve prolapse - report of 3 cases

    International Nuclear Information System (INIS)

    Han, Moon Hee; Im, Chung Ki; Im, Dong Ran; Han, Man Chung; Lee, Young Woo; Seo, Jung Don

    1979-01-01

    Prolapse of mitral valve is characterized by its unique auscultatory, echocardiographic and angiographic findings and may be associated with various disease entities such as congenital heart disease, coronary heart disease and Marfan's syndrome etc. Authors report recent experience of 3 cases of prolapsed mitral valve, 2 cases associated with A.S.D. and 1 case with Marfan's syndrome.

  2. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  3. Markers of Oxidative Stress in Dogs with Myxomatous Mitral Valve Disease are Influenced by Sex, Neuter Status, and Serum Cholesterol Concentration

    DEFF Research Database (Denmark)

    Reimann, M. J.; Haggstrom, J.; Moller, J. E.

    2017-01-01

    Background Cardiovascular disease has been associated with oxidative stress, which has been suggested to contribute to myocardial remodeling in human patients. Little is known about the relationship between myxomatous mitral valve disease (MMVD) and oxidative stress in dogs. Objective To determin...... with clinical stage of MMVD. Conclusions In conclusion, markers of oxidative stress are associated with sex, BCS, neuter status, and cholesterol. The results cannot confirm a relationship between oxidative stress and clinical stage of the disease in dogs with MMVD.......Background Cardiovascular disease has been associated with oxidative stress, which has been suggested to contribute to myocardial remodeling in human patients. Little is known about the relationship between myxomatous mitral valve disease (MMVD) and oxidative stress in dogs. Objective To determine...... whether clinical stage of MMVD is associated with changes in the plasma concentrations of certain markers of oxidative stress in clinically healthy dogs and dogs with MMVD. Animals Seventy five privately owned dogs: 59 cavalier King Charles Spaniels (CKCS) with different severities of MMVD and 16 dogs...

  4. Abnormal Gastroesophageal Flap Valve Is Associated With High Gastresophageal Reflux Disease Questionnaire Score and the Severity of Gastroesophageal Reflux Disease in Vietnamese Patients With Upper Gastrointestinal Symptoms.

    Science.gov (United States)

    Quach, Duc T; Nguyen, Trang T; Hiyama, Toru

    2018-04-30

    There have been no studies investigating the distribution of abnormal gastroesophageal flap valve (GEFV) among patients with dyspepsia, non-erosive reflux disease (NERD), and reflux esophagitis (RE) in the same set of patients. The aims of this study are to investigate (1) the association between GEFV and gastroesophageal reflux disease questionnaire (GERDQ) score, and (2) the distribution of abnormal GEFV in Vietnamese patients presenting with upper gastrointestinal symptoms. Three hundred and thirty-one patients recruited in this prospective cross-sectional study were classified into 3 groups: reflux esophagitis (RE), non-erosive reflux disease (NERD) (GERDQ score ≥ 8, no endoscopic mucosal injury), and dyspepsia (GERDQ score < 8, no endoscopic mucosal injury). The GEFV was graded endoscopically according to the Hill classification. GEFV grades I and II were regarded as normal, while grades III and IV were regarded as abnormal GEFV. There were 215 (65.0%) patients with dyspepsia, 55 (16.6%) patients with NERD, and 61 (18.4%) patients with RE. Abnormal GEFV was an independent risk factor for GERD (OR, 2.93; CI 95%, 1.76-4.88) and RE (OR, 3.41; CI 95%, 1.78-6.53). The mean GERDQ score of patients with abnormal GEFV was significantly higher than that of patients with normal GEFV (5.7 ± 2.4 vs 4.9 ± 2.7, P = 0.011). The prevalence of abnormal GEFV gradually increased in patients with dyspepsia (27.4%), NERD (43.6%), grade A RE (56.8%), and grades B/C RE (80.0%) ( P < 0.001). Abnormal GEFV was significantly associated with high GERDQ score. Its prevalence gradually increased in patients with dyspepsia, NERD, and RE, respectively.

  5. Electronic Integrated Disease Surveillance System and Pathogen Asset Control System

    Directory of Open Access Journals (Sweden)

    Tom G. Wahl

    2012-06-01

    Full Text Available Electronic Integrated Disease Surveillance System (EIDSS has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner. It has been used for comprehensive analysis and visualisation capabilities including real time mapping of case events as these unfold enhancing decision making. Electronic Integrated Disease Surveillance System facilitated countries to comply with the IHR 2005 requirements through a data transfer module reporting diseases electronically to the World Health Organisation (WHO data center as well as establish authorised data exchange with other electronic system using Open Architecture approach. Pathogen Asset Control System (PACS has been used for accounting, management and control of biological agent stocks. Information on samples and strains of any kind throughout their entire lifecycle has been tracked in a comprehensive and flexible solution PACS. Both systems have been used in a combination and individually. Electronic Integrated Disease Surveillance System and PACS are currently deployed in the Republics of Kazakhstan, Georgia and Azerbaijan as a part of the Cooperative Biological Engagement Program (CBEP sponsored by the US Defense Threat Reduction Agency (DTRA.

  6. Electronic integrated disease surveillance system and pathogen asset control system.

    Science.gov (United States)

    Wahl, Tom G; Burdakov, Aleksey V; Oukharov, Andrey O; Zhilokov, Azamat K

    2012-06-20

    Electronic Integrated Disease Surveillance System (EIDSS) has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner. It has been used for comprehensive analysis and visualisation capabilities including real time mapping of case events as these unfold enhancing decision making. Electronic Integrated Disease Surveillance System facilitated countries to comply with the IHR 2005 requirements through a data transfer module reporting diseases electronically to the World Health Organisation (WHO) data center as well as establish authorised data exchange with other electronic system using Open Architecture approach. Pathogen Asset Control System (PACS) has been used for accounting, management and control of biological agent stocks. Information on samples and strains of any kind throughout their entire lifecycle has been tracked in a comprehensive and flexible solution PACS.Both systems have been used in a combination and individually. Electronic Integrated Disease Surveillance System and PACS are currently deployed in the Republics of Kazakhstan, Georgia and Azerbaijan as a part of the Cooperative Biological Engagement Program (CBEP) sponsored by the US Defense Threat Reduction Agency (DTRA).

  7. Breeding Restrictions Decrease the Prevalence of Myxomatous Mitral Valve Disease in Cavalier King Charles Spaniels over an 8-to 10-Year Period

    DEFF Research Database (Denmark)

    Birkegård, Anna Camilla; Reimann, M. J.; Martinussen, T.

    2016-01-01

    Background: Cavalier King Charles Spaniels (CKCS) are predisposed to myxomatous mitral valve disease (MMVD). Studies have indicated a strong genetic background. Objective: The aim of this study was to evaluate the effect of a breeding scheme involving auscultation and echocardiography. Animals......: In the Danish Kennel Club mandatory breeding scheme, 997 purebred CKCS were examined during the period 2002-2011. Each dog was evaluated 1-4 times with a total of 1,380 examinations. Methods: Auscultation and echocardiography were performed to evaluate mitral regurgitation murmur severity and degree of mitral...... compared with dogs in 2002-2003, reflecting a 73% decreased risk (P auscultation...

  8. Feasibility of electron beam tomography in diagnosis of congenital heart disease: comparison with echocardiography

    International Nuclear Information System (INIS)

    Lee, Jongmin J.; Kang, Duk-Sik

    2001-01-01

    Objective: To evaluate the feasibility of electron beam tomography (EBT) for morphological assessment of congenital heart disease. Materials and methods: Sixteen subjects were examined by EBT, transthoracic echocardiography, cardiac cine angiography and surgery. EBT scan was performed using single slice continuous volume mode to acquire high-resolution static image. Double dose contrast medium was injected by bolus technique after measuring scan delay time and calculation of proper injection rate. The results of EBT and echocardiography were compared based on the results of cardiac cine angiography and surgical findings. All anomalous components were evaluated in all subjects and grouped according to major cardiac structures. Statistical analysis was performed to compare two modalities' ability to evaluate the anomalies of major structures. Results: EBT was more sensitive to evaluate the anomalies of systemic vessels, pulmonary vessels and small systemic arteries such as coronary artery. EBT was less sensitive to identify the abnormality of cardiac valves such as valvular regurgitation. There was no difference of sensitivity in evaluation of cardiac chambers and septa between the two modalities. Conclusion: EBT assisted by transthoracic echocardiography is excellent noninvasive modality to diagnose congenital heart disease

  9. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  10. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  11. Effects of structure parameters on the static electromagnetic characteristics of solenoid valve for an electronic unit pump

    International Nuclear Information System (INIS)

    Sun, Zuo-Yu; Li, Guo-Xiu; Wang, Lan; Wang, Wei-Hong; Gao, Qing-Xiu; Wang, Jie

    2016-01-01

    Highlights: • The static electromagnetic characteristics of solenoid valve were numerically studied. • The effects of driving current were considered. • The effects of solenoid valve’s eight essential structure parameters were considered. - Abstract: In the present paper, the effects of driving current and solenoid valve’s structure parameters (including iron-core’s length, magnetic pole’s cross-sectional area, coil turn, coil’s position, armature’s thickness, damping hole’s position, damping hole’s size, and width of working air–gap) on the static electromagnetic characteristics have been numerically investigated. From the results, it can be known that the electromagnetic energy conversion will be seriously influenced by driving current for its effects on magnetic field strength and magnetic saturation phenomenon, an excessive increase of current will weak electromagnetic energy conversion for the accelerating power losses. The capacity of electromagnetic energy conversion is also relative to each solenoid valve’s parameter albeit it is not very sensitive to each parameters. The generated electromagnetic force will be enhanced by rising iron-core’s length, equalizing the cross-sectional areas of major and vice poles, increasing coil turn within a moderate range, closing the coil’s position towards armature’s centre, enlarging armature’s thickness, pushing the damping holes’ positions away from armature’s centre, reducing the sizes of damping holes, and reducing the width of working air–gap; but such enhancements won’t be realized once the driving current is excessively higher.

  12. Management of Posterior Urethral Valves in Rural Kenya

    African Journals Online (AJOL)

    Management of Posterior Urethral Valves in Rural. Kenya .... Antwi S. Audit of Posterior Urethral Valve (PUV) in Children at ... Community Paediatrics Committee, Infectious. Diseases ... Effect of Circumcision on Risk of Urinary Tract. Infection in ...

  13. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  14. Increased NT-proANP predicts risk of congestive heart failure in Cavalier King Charles spaniels with mitral regurgitation caused by myxomatous valve disease.

    Science.gov (United States)

    Eriksson, Anders S; Häggström, Jens; Pedersen, Henrik Duelund; Hansson, Kerstin; Järvinen, Anna-Kaisa; Haukka, Jari; Kvart, Clarence

    2014-09-01

    To evaluate the predictive value of plasma N-terminal pro-atrial natriuretic peptide (NT-proANP) and nitric oxide end-products (NOx) as markers for progression of mitral regurgitation caused by myxomatous mitral valve disease. Seventy-eight privately owned Cavalier King Charles spaniels with naturally occurring myxomatous mitral valve disease. Prospective longitudinal study comprising 312 measurements over a 4.5 year period. Clinical values were recorded, NT-proANP concentrations were measured by radioimmunoassay, and NOx were analyzed colorimetrically. To predict congestive heart failure (CHF), Cox proportional hazards models with time-varying covariates were constructed. The hazard ratio for NT-proANP (per 1000 pmol/l increase) to predict future CHF was 6.7 (95% confidence interval, 3.6-12.5; p 1000 pmol/l was 11 months (95% confidence interval, 5.6-12.6 months), compared to 54 months (46 - infinity) for dogs with concentrations ≤ 1000 pmol/l (p 130 beats per minute) and grade of murmur (≥ 3/6). The risk of CHF due to mitral regurgitation is increased in dogs with blood NT-proANP concentrations above 1000 pmol/l. Measurement of NT-proANP can be a valuable tool to identify dogs that may develop CHF within months. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  16. A happy valve in a happy patient? Serotonergic antidepressants and the risk of valvular heart disease (SERVAL). A case-control study.

    Science.gov (United States)

    De Backer, Tine; Petrovic, Mirko; Audenaert, Kurt; Coeman, Mathieu; De Bacquer, Dirk

    2016-02-01

    The objective was to investigate the risk of valvular heart disease in humans in relation to the use of selective serotonin reuptake inhibitors (SSRIs) and serotonin and noradrenaline reuptake inhibitors. A case-control study. We conducted a case-control study within this cohort in which patients with newly diagnosed cardiac valve regurgitation were age-matched to controls. Patient demographics, their cardiovascular risk factors and medication use were extracted in both series. Use of SSRIs, serotonin and noradreline reuptake inhibitors (SNRIs) and other pro-serotonergic agents, their dose and treatment duration were recorded. Logistic regression analysis was used to establish the strength of the association between SSRI/SNRI use and valvular heart disease. Outpatient clinic of the cardiology department at the Ghent University Hospital, East-Flanders in Belgium. Total of 2911 persons 21-58 years of age who had undergone an echocardiogram in the period 2006-2010 and had no known cardiovascular disease or previous cardiac intervention. Two hundred and six echocardiographically proven cases of valvular regurgitation and 195 matched controls. Odd ratio of valvular disease associated with intake of serotonergic drugs. Of the 206 patients with newly diagnosed cardiac valve regurgitation, 11.6% were exposed to serotonergic agents compared to 4.1% in the 195 control patients, leading to an odds ratio of 3.08 (95% confidence interval [CI] 1.35-7.04). The analysis of doses and treatment durations revealed a dose-relationship pattern between SSRI/SNRI use and prevalent valvular heart disease. In this study, use of serotonergic antidepressants was associated with an increased rate of valvular regurgitation in humans.

  17. Monitoring emerging diseases of fish and shellfish using electronic sources.

    Science.gov (United States)

    Thrush, M A; Dunn, P L; Peeler, E J

    2012-10-01

    New and emerging fish and shellfish diseases represent an important constraint to the growth and sustainability of many aquaculture sectors and have also caused substantial economic and environmental impacts in wild stocks. This paper details the results of 8 years of a monitoring programme for emerging aquatic animal diseases reported around the world. The objectives were to track global occurrences and, more specifically, to identify and provide advanced warning of disease threats that may affect wild and farmed fish stocks in the UK. A range of electronic information sources, including Internet newsletters, alerting services and news agency releases, was systematically searched for reports of new diseases, new presentations of known pathogens and known diseases occurring in new geographic locations or new host species. A database was established to log the details of key findings, and 250 emerging disease events in 52 countries were recorded during the period of study. These included 14 new diseases and a further 16 known diseases in new species. Viruses and parasites accounted for the majority of reports (55% and 24%, respectively), and known diseases occurring in new locations were the most important emerging disease category (in which viruses were dominant). Emerging diseases were reported disproportionally in salmonid species (33%), in farmed populations (62%) and in Europe and North America (80%). The lack of reports from some regions with significant aquaculture or fishery production may indicate that emerging diseases are not being recognized in these areas owing to insufficient surveillance or testing or that these events are being under-reported. The results are discussed in relation to processes underpinning disease emergence in the aquatic environment. © 2011 Crown Copyright. Reproduced with the permission of the Controller of Her Majesty’s Stationery Office and Centre for Environment Fisheries & Aquaculture Science.

  18. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  19. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  20. Role of Pre-incision, Intravenous Prophylactic Amiodarone to Control Arrhythmias in Patients with Rheumatic Valvular Heart Disease undergoing Mitral Valve Replacement

    International Nuclear Information System (INIS)

    Ahmad, K.; Naqvi, S.

    2013-01-01

    Objective: To evaluate the effect of intra-operative single intra venous dose of amiodarone on post operative cardiac arrhythmias in patients undergoing valvular heart surgery. Study Design: Randomized controlled trials. Place and Duration of surgery: This study was performed at Armed forces Institute of Cardiology Rawalpindi from Jan 01, 2011 to Dec 31, 2011. Patients and Methods: In this study 80 patients with rheumatic valvular heart disease and undergoing elective mitral valve replacement were randomly divided into two groups. Group I, n = 40 (Amiodarone group) was given single intravenous dose of amiodarone (5 mg/kg in 100 ml of saline over 30 min) before sternotomy incision. Group II, n = 40(control / placebo group) was given 100 ml of saline over 30 min. Result: In the amiodarone group, after removal of aortic cross clamp 75% patients had sinus rhythm compared to 47.5% in control group. p=0.045. Similarly 15% had AF, 5% JR and 5% VT/VF in amiodarone group in contrast to 32.5% with AF, 12.5% JR and 7.5% Vt/VF in control group. (p=0.045). Response to cardioversion was positive in 75% of the patients requiring shocks in amiodarone group as against 43.75% in the control group. (p=0.044). Conclusion: A single intravenous bolus dose of amiodarone is effective in decreasing the incidence of cardiac arrhythmias after mitral valve replacement in patients with rheumatic MVD. (author)

  1. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  2. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  3. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  4. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  5. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  6. Mitral valve prolapse - report of 3 cases

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Im, Chung Ki; Im, Dong Ran; Han, Man Chung; Lee, Young Woo; Seo, Jung Don [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-12-15

    Prolapse of mitral valve is characterized by its unique auscultatory, echocardiographic and angiographic findings and may be associated with various disease entities such as congenital heart disease, coronary heart disease and Marfan's syndrome etc. Authors report recent experience of 3 cases of prolapsed mitral valve, 2 cases associated with A.S.D. and 1 case with Marfan's syndrome.

  7. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  8. Left atrial and left ventricular diastolic function after the maze procedure for atrial fibrillation in mitral valve disease: degenerative versus rheumatic.

    Science.gov (United States)

    Kim, Hwan Wook; Moon, Mi Hyoung; Jo, Keon Hyun; Song, Hyun; Lee, Jae Won

    2015-02-01

    The present study was aimed to compare the left atrial and left ventricular diastolic functions amongst the rheumatic and degenerative mitral valve disease patients in atrial fibrillation who reverted to normal sinus rhythm following Cox-maze procedure. We prospectively investigated the left atrial and left ventricular function with Doppler echocardiography, by dividing into the rheumatic (N = 105) and the degenerative group (N = 47). Over the follow-up period (mean: 4.4 ± 1.2 years in the rheumatic group, 4.8 ± 1.3 years in the degenerative group), the rheumatic group showed statistically significant decrease in A' velocity and E' velocity, on contrary to degenerative group (A' velocity: mean decrease of 0.43 ± 0.13 cm/s in the rheumatic group, mean increase of 0.57 ± 0.11 cm/s in the degenerative group, p = 0.029, E' velocity: mean decrease of 0.23 ± 0.17 cm/s in the rheumatic group, mean increase of 0.21 ± 0.15 cm/s in the degenerative group, p = 0.031). In addition, the rheumatic group showed statistically significant increase in E/E' ratio than the degenerative group (mean increase of 4.49 ± 1.98 in the rheumatic group, mean increase of 1.74 ± 1.52 in the degenerative group, p = 0.047). Despite successful sinus rhythm restoration, the progressive loss of LA function as well as LV diastolic function is more prominent in the rheumatic group than the degenerative group. Therefore, differentiated strategies for postoperative surveillance are needed according to the pathology of mitral valve disease.

  9. Alpha-smooth muscle actin and serotonin receptors 2A and 2B in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Cremer, Signe Emilie; Moesgaard, S. G.; Rasmussen, C. E.

    2015-01-01

    suggested. In an age-matched population of dogs with non-clinical and clinical MMVD, the objectives were to investigate (1) gene expression of 5-HT2AR and 5-HT2BR, (2) protein expression and spatial relationship of 5-HT2AR, 5-HT2BR and MF in the mitral valve (MV) and the cardiac anterior papillary muscle...... (AP) and (3) serum 5-HT concentrations. Gene expression of 5-HT2BR was significantly higher in MV and AP among dogs with clinical MMVD. This was not found for 5-HT2BR protein expression, though association of 5-HT2BR with myxomatous pathology and co-localization of 5-HT2BR and MF in MV and AP support...

  10. Residual glycosaminoglycan accumulation in mitral and aortic valves of a patient with attenuated MPS I (Scheie syndrome after 6 years of enzyme replacement therapy: Implications for early diagnosis and therapy

    Directory of Open Access Journals (Sweden)

    Yohei Sato

    2015-12-01

    Full Text Available Mucopolysaccharidosis (MPS is an inherited metabolic disease caused by deficiency of the enzymes needed for glycosaminoglycan (GAG degradation. MPS type I is caused by the deficiency of the lysosomal enzyme alpha-l-iduronidase and is classified into Hurler syndrome, Scheie syndrome, and Hurler–Scheie syndrome based on disease severity and onset. Cardiac complications such as left ventricular hypertrophy, cardiac valve disease, and coronary artery disease are often observed in MPS type I. Enzyme replacement therapy (ERT has been available for MPS type I, but the efficacy of this treatment for cardiac valve disease is unknown. We report on a 56-year-old female patient with attenuated MPS I (Scheie syndrome who developed aortic and mitral stenosis and coronary artery narrowing. The cardiac valve disease progressed despite ERT and she finally underwent double valve replacement and coronary artery bypass grafting. The pathology of the cardiac valves revealed GAG accumulation and lysosomal enlargement in both the mitral and aortic valves. Zebra body formation was also confirmed using electron microscopy. Our results suggest that ERT had limited efficacy in previously established cardiac valve disease. Early diagnosis and initiation of ERT is crucial to avoid further cardiac complications in MPS type I.

  11. Magnon Valve Effect between Two Magnetic Insulators

    Science.gov (United States)

    Wu, H.; Huang, L.; Fang, C.; Yang, B. S.; Wan, C. H.; Yu, G. Q.; Feng, J. F.; Wei, H. X.; Han, X. F.

    2018-03-01

    The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.

  12. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  13. Cardiac taurine and principal amino acids in right and left ventricles of patients with either aortic valve stenosis or coronary artery disease:the importance of diabetes and gender

    OpenAIRE

    Lewis, Martin J; Littlejohns, Ben R; Lin, Hua; Angelini, Gianni D; Suleiman, M-Saadeh

    2014-01-01

    Free intracellular taurine and principal α-amino acids (glutamate, glutamine, aspartate, asparagine and alanine) are abundant in human heart. They are cellular regulators and their concentration can change in response to disease and cardiac insults and have been shown to differ between hypertrophic left ventricle (LV) and the relatively "normal" right ventricle (RV) in patients with aortic valve stenosis (AVS). This difference has not been shown for coronary artery disease (CAD) and there are...

  14. Is aortopathy in bicuspid aortic valve disease a congenital defect or a result of abnormal hemodynamics? A critical reappraisal of a one-sided argument.

    Science.gov (United States)

    Girdauskas, Evaldas; Borger, Michael A; Secknus, Maria-Anna; Girdauskas, Gracijus; Kuntze, Thomas

    2011-06-01

    Although there is adequate evidence that bicuspid aortic valve (BAV) is an inheritable disorder, there is a great controversy regarding the pathogenesis of dilatation of the proximal aorta. The hemodynamic theory was the first explanation for BAV aortopathy. The genetic theory, however, has become increasingly popular over the last decade and can now be viewed as the clearly dominant one. The widespread belief that BAV disease is a congenital disorder of vascular connective tissue has led to more aggressive treatment recommendations of the proximal aorta in such patients, approaching aortic management recommendations for patients with Marfan syndrome. There is emerging evidence that the 'clinically normal' BAV is associated with abnormal flow patterns and asymmetrically increased wall stress in the proximal aorta. Recent in vitro and in vivo studies on BAV function provide a unique hemodynamic insight into the different phenotypes of BAV disease and asymmetry of corresponding aortopathy even in the presence of a 'clinically normal' BAV. On the other hand, there is a subgroup of young male patients with BAV and a root dilatation phenotype, who may present the predominantly genetic form of BAV disease. In the face of these important findings, we feel that a critical review of this clinical problem is timely and appropriate, as the prevailing BAV-aortopathy theory undoubtedly affects the surgical approach to this common clinical entity. Thorough analysis of the recent literature shows a growing amount of evidence supporting the hemodynamic theory of aortopathy in patients with BAV disease. Data from recent studies requires a reevaluation of our overwhelming support of the genetic theory, and obliges us to acknowledge that hemodynamics plays an important role in the development of this disease process. Given the marked heterogeneity of BAV disease, further studies are required in order to more precisely determine which theory is the 'correct' one for explaining the

  15. Comparison of outcomes of tricuspid annuloplasty with 3D-rigid versus flexible prosthetic ring for functional tricuspid regurgitation secondary to rheumatic mitral valve disease.

    Science.gov (United States)

    Wang, Haiping; Liu, Xiancheng; Wang, Xin; Lv, Zhenqian; Liu, Xiaojun; Xu, Ping

    2016-11-01

    Annuloplasty bands and rings are widely used for repairing functional tricuspid regurgitation (FTR). However, the question regarding which is the ideal annuloplasty device remains unclear. The aim of this study was to compare the efficacy and mid-term durability of tricuspid ring annuloplasty for FTR secondary to rheumatic mitral valve disease using flexible Cosgrove-Edwards band and the rigid Edwards MC3 ring (Edwards Lifesciences, LLC, Irvine, CA, USA). We retrospectively collected the clinical data of those who underwent mitral valve replacement (MVR) in concomitant with tricuspid ring annuloplasty from 2009 to 2013. The flexible band was used in 46 patients (flexible group), and the 3D rigid ring was used in 60 patients (rigid group). Echocardiographic evaluation of tricuspid function was performed preoperatively and postoperatively. The grade of TR was significantly improved compared to preoperative values in two groups. There was no significant difference regarding postoperative TR grade between the two groups at 1 week and 2-3 months but there was statistical significant difference at postoperative 6-12 months, and 2-3 years. During the follow up period, 25 of 46 patients (54.3%) in flexible group and 22 of 60 patients (30.3%) in rigid group developed recurrent TR. Freedom from recurrent TR in flexible group is significant lower than rigid group in each postoperative follow up period. These findings suggest that 3D rigid ring annuloplasty might be more effective for tricuspid ring annuloplasty in FTR in mid-term postoperative periods when compared to flexible band.

  16. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  17. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  18. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  19. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  20. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  1. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  2. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  3. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  4. Fatty acid metabolism in symptomatic patients with mitral valve prolapse but without coronary artery disease - comparison with 201Tl myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Voth, E.; Schicha, H.; Neumann, P.; Emrich, D.; Tebbe, U.

    1987-01-01

    Using 123 I-ω-heptadecanoic acid (HDA) and 201 Tl, respectively, myocardial fatty acid metabolism and perfusion were studied in 51 symptomatic patients with mitral valve prolapse (MVP) as diagnosed by ventriculography, and no evidence of coronary artery disease. Twelve subjects with normal coronary arteries and normal ventriculogram served as a control group for the evaluation of elimination kinetics of HDA. In the control group, the mean elimination half-life was 26.1±3.6 min, whereas the patients with MVP had a mean value of 25.0±6.4 min. In patients with MVP, a high incidence concerning abnormalities of accumulation and/or elimination of HDA occurred, namely accumulation defects in 31% and both prolonged and shortened elimination half-lives in 16% and 29%, respectively. Myocardial perfusion scintigraphy using 201 Tl showed abnormalities in 76%. Correlations were found between decreased uptake of HDA and prolonged elimination half-life as well as defects by 201 Tl, presumably due to ischemia based on small-vessel disease or abnormalities of cellular metabolism. (orig.) [de

  5. Periodontal bacteria DNA findings in human cardiac tissue - Is there a link of periodontitis to heart valve disease?

    Science.gov (United States)

    Ziebolz, D; Jahn, C; Pegel, J; Semper-Pinnecke, E; Mausberg, R F; Waldmann-Beushausen, R; Schöndube, F A; Danner, B C

    2018-01-15

    The aim of the study was to detect periodontal pathogens DNA in atrial and myocardial tissue, and to investigate periodontal status and their connection to cardiac tissue inflammation. In 30 patients, biopsy samples were taken from the atrium (A) and the ventricle myocardium (M) during aortic valve surgery. The dental examination included the dental and periodontal status (PS) and a collection of a microbiological sample. The detection of 11 periodontal pathogens DNA in oral and heart samples was carried out using PCR. The heart samples were prepared for detecting the LPS-binding protein (LBP), and for inflammation scoring on immunohistochemistry (IHC), comprising macrophages (CD68), LPS-binding protein receptor (CD14), and LBP (big42). 28 (93%) patients showed moderate to severe periodontitis. The periodontal pathogens in the oral samples of all patients revealed a similar distribution (3-93%). To a lesser extent and with a different distribution, these bacteria DNA were also detected in atrium and myocardium (3-27%). The LBP was detected in higher amount in atrium (0.22±0.16) versus myocardium (0.13±0.13, p=0.001). IHC showed a higher inflammation score in atrial than myocardial tissue as well as for CD14, CD68 and for LBP. Additional, periodontal findings showed a significant correlation to CD14 and CD68. The results provide evidence of the occurrence of oral bacteria DNA at the cardiac tissue, with a different impact on atrial and myocardial tissue inflammation. Influence of periodontal findings was identified, but their relevance is not yet distinct. Therefore further clinical investigations with long term implication are warranted. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  7. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  8. Recurrent infective endocarditis causing heart valve failure: A case report

    Directory of Open Access Journals (Sweden)

    Victoria McIntyre, BASc Chemical Engineering (2018 candidate

    2017-11-01

    Full Text Available Infective endocarditis (IE is an infection that does not usually respond rapidly to treatment, often because its early symptoms are non-specific. The diseased valves (native or bioprosthetic may be calcified and the thrombotic vegetations on them typically friable and embolize easily. Left untreated IE leads to damage to the infected valve and to congestive heart failure (CHF. Its treatment usually requires heart valve replacement. Our 69-year-old patient had IE, and underwent aortic valve replacement (AVR with a bioprosthesis. This case stresses the complications of IE and its tendency to recur in patients with bioprosthetic heart valves (BHV who previously had IE.

  9. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  10. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  11. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  12. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  13. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  14. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  15. Open source electronic health records and chronic disease management.

    Science.gov (United States)

    Goldwater, Jason C; Kwon, Nancy J; Nathanson, Ashley; Muckle, Alison E; Brown, Alexa; Cornejo, Kerri

    2014-02-01

    To study and report on the use of open source electronic health records (EHR) to assist with chronic care management within safety net medical settings, such as community health centers (CHC). The study was conducted by NORC at the University of Chicago from April to September 2010. The NORC team undertook a comprehensive environmental scan, including a literature review, a dozen key informant interviews using a semistructured protocol, and a series of site visits to CHC that currently use an open source EHR. Two of the sites chosen by NORC were actively using an open source EHR to assist in the redesign of their care delivery system to support more effective chronic disease management. This included incorporating the chronic care model into an CHC and using the EHR to help facilitate its elements, such as care teams for patients, in addition to maintaining health records on indigent populations, such as tuberculosis status on homeless patients. The ability to modify the open-source EHR to adapt to the CHC environment and leverage the ecosystem of providers and users to assist in this process provided significant advantages in chronic care management. Improvements in diabetes management, controlled hypertension and increases in tuberculosis vaccinations were assisted through the use of these open source systems. The flexibility and adaptability of open source EHR demonstrated its utility and viability in the provision of necessary and needed chronic disease care among populations served by CHC.

  16. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  17. Mitral valve surgery in the adult Marfan syndrome patient.

    Science.gov (United States)

    Bhudia, Sunil K; Troughton, Richard; Lam, Buu-Khanh; Rajeswaran, Jeevanantham; Mills, William R; Gillinov, A Marc; Griffin, Brian P; Blackstone, Eugene H; Lytle, Bruce W; Svensson, Lars G

    2006-03-01

    Because mitral valve dysfunction in adults with Marfan syndrome is poorly characterized, this study compares mitral valve pathophysiology and morphology with that of myxomatous mitral disease, documents types of mitral valve operations, and assesses long-term survival and durability of mitral valve surgery in Marfan patients. From May 1975 to June 2000, 27 adults with Marfan syndrome underwent mitral valve surgery. Their valve pathophysiology and morphology was compared with that of 119 patients with myxomatous mitral disease undergoing surgery from September 1995 to March 1999. Survival and repair durability were assessed at follow-up. Compared with myxomatous disease patients, Marfan patients had less posterior leaflet prolapse (44% versus 70%, p = 0.01), more bileaflet (44% versus 28%, p = 0.09) and anterior leaflet prolapse (11% versus 3%, p = 0.07), and presented earlier for surgery (age 41 +/- 12 years versus 57 +/- 13, p Marfan patients had longer and thinner leaflets. Mitral valve repair was performed less frequently in Marfan (16 of 27, 59%) than myxomatous disease patients (112 of 119, 94%). There were no hospital deaths; at 10 years, survival was 80% and freedom from reoperation 96%, with only 1 reoperation among the 16 repairs. Mitral valve pathophysiology and morphology differ between Marfan and myxomatous mitral valve diseases. Valve repair in Marfan patients is durable and gives acceptable long-term results, even in adults who present with advanced mitral valve pathology. With increasing use of the modified David reimplantation operation and sparing of the aortic valve, mitral valve repair is a greater imperative, particularly since we have not had to reoperate on any Marfan patients with reimplantations.

  18. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  19. Synthetic imaging diagnosis of valvular heart diseases (especially, mytral valve), for the most part of angled projections in cineangiocardiographic study

    International Nuclear Information System (INIS)

    Katabuchi, Tetsuro; Wakamatsu, Takashi; Nakayama, Kazuhiko

    1981-01-01

    Recently, owing to developments of high output X-ray tube, high resolution image intensifier and mobile U or C arm, increasing remarkably, has been application of cinegraphy to angiocardiographic study. Surgical treatments for heart diseases have been very advanced in this few years, so that before operation, is demanded to precise anatomically and functionally diagnosis of them. In this paper, are discussed cineangiocardiography, echocardiography, in regard to the most useful investigation of valvelar heart diseases and some problems of imaging techniques, finally, introduced the newest examination method of diagnostic imaging. (author)

  20. A 29-Year-Old Harken Disk Mitral Valve

    Science.gov (United States)

    Hsi, David H.; Ryan, Gerald F.; Taft, Janice; Arnone, Thomas J.

    2003-01-01

    An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patient's 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features. (Tex Heart Inst J 2003;30:319–21) PMID:14677746

  1. Mitral valve prolapse and hyperthyroidism: effect of patient selection.

    Science.gov (United States)

    Zullo, M A; Devereux, R B; Kramer-Fox, R; Lutas, E M; Brown, W T

    1985-11-01

    Patients with mitral valve prolapse and hyperthyroidism have common symptoms; the most outstanding symptom is palpitation. To determine whether or not common symptoms contributed to the reported association of these conditions, we evaluated 220 patients with symptomatic mitral valve prolapse and 216 first-degree relatives in 72 families; 65 relatives with mitral valve prolapse and 151 relatives without mitral valve prolapse, all greater than or equal to 16 years of age. Thirty subjects, aged 49 +/- 13 years (p less than 0.025 vs entire study group), had thyroid disease (23 subjects had definite thyroid disease, seven subjects had probable); 27 of 30 subjects with thyroid disease (90%) were female (p less than 0.005). The age- and sex-adjusted prevalence of hyperthyroidism was significantly higher in probands with mitral valve prolapse than in family members without mitral valve prolapse (3.5% vs 0%, p = 0.03), while an intermediate prevalence of hyperthyroidism (2.2%) was observed in family members with mitral valve prolapse. Thus, the prevalence of hyperthyroidism is increased among symptomatic patients with mitral valve prolapse as compared to family members without mitral valve prolapse, but the prevalence of thyroid conditions is similar among family members with or without this condition. These findings are explained by the effect of common symptoms on clinical detection of both mitral valve prolapse and hyperthyroidism.

  2. Ventricular perforation as a complication of percutaneous valve ...

    African Journals Online (AJOL)

    Aortic stenosis (AS) is the most commonly encountered valvular disease in developed countries. Once symptomatic, this disease carries a dismal prognosis. Patients unfit for surgical valve replacement may require transcatheter aortic valve implantations (TAVI). We present a complication of this novel approach where a ...

  3. Desenvolvimento de circuito eletrônico comparador para controle de válvulas de vazões reduzidas = Development of comparative electronic circuit for reduced flow valve control

    Directory of Open Access Journals (Sweden)

    Ana Maria Frattini Fileti

    2011-04-01

    Full Text Available Diversos tipos de válvula de controle de vazão estão disponíveiscomercialmente, sendo a maioria delas apropriada para elevadas vazões e provida de acionamento pneumático para reduzir riscos de explosões em ambientes industriais. As válvulas para vazões reduzidas e baixas pressões são de pequenas dimensões, normalmente eletrônicas e apresentam custo elevado. No presente trabalho foi desenvolvido um sistema de controle eletrônico de vazão por computador on-line, baseado em componentes eletrônicos comuns, em esquema comparativo de tensão. Um amplificador subtrador foi utilizado neste circuito eletrônico, comparando dois valores de tensão para o controle dosentido de rotação e parada do motorredutor de velocidade acoplado à haste da válvula agulha comum. Este sistema de baixo custo se mostrou eficiente e de simples montagem eletrônica. Válvulas de diferentes dimensões foram acopladas com sucesso ao motorredutor comandado pelo circuito eletrônico, conferindo flexibilidade ao atuador desenvolvido.Ensaios de calibração e de determinação de tempo morto são apresentados, obtendo-se como menor faixa de vazão os valores de 0,3 a 3,6 mL s-1.Different types of flow control valves are commercially available but most are only adequate for high flow rates. These are provided with pneumatic devices to reduce explosion risks in industrial plants. Flow-reduced and low pressure valves are small sized, usually driven by analogical signals and very expensive. Current assay developed an on-line computer-aided flow control electronic system made up of common electronic components within a comparative voltage scheme. A subtracted amplifier was employed in the electronic circuit which compares two voltages for rotation direction control and stoppage of speed engine reducer linked to the common valve stem. This low cost system is very efficient and has the advantage of being electronically assembled without any difficulty. Different

  4. Utility of Tissue Doppler Imaging in the Echocardiographic Evaluation of Left and Right Ventricular Function in Dogs with Myxomatous Mitral Valve Disease with or without Pulmonary Hypertension.

    Science.gov (United States)

    Baron Toaldo, M; Poser, H; Menciotti, G; Battaia, S; Contiero, B; Cipone, M; Diana, A; Mazzotta, E; Guglielmini, C

    2016-05-01

    In human medicine, right ventricular (RV) functional parameters represent a tool for risk stratification in patients with congestive heart failure caused by left heart disease. Little is known about RV alterations in dogs with left-sided cardiac disorders. To assess RV and left ventricular (LV) function in dogs with myxomatous mitral valve disease (MMVD) with or without pulmonary hypertension (PH). One-hundred and fourteen dogs: 28 healthy controls and 86 dogs with MMVD at different stages. Prospective observational study. Animals were classified as healthy or having MMVD at different stages of severity and according to presence or absence of PH. Twenty-eight morphological, echo-Doppler, and tissue Doppler imaging (TDI) variables were measured and comparison among groups and correlations between LV and RV parameters were studied. No differences were found among groups regarding RV echo-Doppler and TDI variables. Sixteen significant correlations were found between RV TDI and left heart echocardiographic variables. Dogs with PH had significantly higher transmitral E wave peak velocity and higher E/e' ratio of septal (sMV) and lateral (pMV) mitral annulus. These 2 variables were found to predict presence of PH with a sensitivity of 84 and 72%, and a specificity of 71 and 80% at cut-off values of 10 and 9.33 for sMV E/e' and pMV E/e', respectively. No association between variables of RV function and different MMVD stage and severity of PH could be detected. Some relationships were found between echocardiographic variables of right and left ventricular function. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  5. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  6. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  7. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  8. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  9. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  10. Bentall Procedure Using Cryopreserved Valved Aortic Homografts

    Science.gov (United States)

    Christenson, Jan T.; Sierra, Jorge; Trindade, Pedro T.; Didier, Dominique; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 ± 21 years (range, 15–74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 ± 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6–72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft. PMID:15745290

  11. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  12. ORGANIC TRICUSPID VALVE REPAIR WITH AUTOLOGOUS GLUTARALDEHYDE FIXED PERICARDIAL PATCH : A SINGLE CENTER RESULTS

    Directory of Open Access Journals (Sweden)

    Murtaza A

    2015-10-01

    Full Text Available AIM AND OBJECTIVE: The aim of this study was to determine the effectiveness and results of repair of Organic Tricuspid Valve disease. INTRODUCTION : since tricuspid valve disease most often found in association with other valve disease. Isolated tricuspid valve disease is ra re. Pattern of involvement of tricuspid valve disease shows functional (75% and primary (organic in (25%. Surgical repair of organic tricuspid valve disease often fails because of abnormal valve. This usually leads to limited options. This study examine s our experience of tricuspid valve repair with autologous pericardium for organic tricuspid valve disease. MATERIAL AND METHODS : From Jan 2014 to May 2015, 22 patients underwent repairs for organic tricuspid valve disease. The patient aged 15 to 65 years and all were in New York Heart Association (NYHA class of III or IV. All patients presented with severe tricuspid disease coexisting with other cardiac pathology, usually left - sided heart valve disease. Repair techniques included Commisurotomy, division o f secondary chordae, Glutaraldehyde treated autologous pericardial patch augmentation of tricuspid valve leaflets, anterior papillary muscle advancement etc with or without ring/suture annuloplasty. Follow - up duration was 3 to 18 months. RESULTS : No deaths or late reoperations occurred. All patients demonstrated clinical improvements on follow up. Echocardiographic studies before hospital discharge showed less than mild tricuspid regurgitation in all patients except one. CONCLUSIONS : Large majorit y of organic tricuspid valve regurgitation is repairable with acceptable early results. Tricuspid stenosis and mixed tricuspid valve disease are more challenging. In the latter group, it is a judgment call whether to accept a suboptimal result or replace t he valve

  13. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  14. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  15. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  16. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    International Nuclear Information System (INIS)

    Gooley, Robert P.; Cameron, James D.; Soon, Jennifer; Loi, Duncan; Chitale, Gauri; Syeda, Rifath; Meredith, Ian T.

    2015-01-01

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  17. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    Energy Technology Data Exchange (ETDEWEB)

    Gooley, Robert P., E-mail: robert.gooley@monashhealth.org [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Cameron, James D., E-mail: james.cameron@monash.edu [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Soon, Jennifer, E-mail: jenn.sa@gmail.com [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Loi, Duncan, E-mail: dloi2@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Chitale, Gauri, E-mail: gchi21@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Syeda, Rifath, E-mail: rssye1@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Meredith, Ian T., E-mail: ian.meredith@myheart.id.au [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia)

    2015-09-15

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  18. Short-term to Long-term Results of Ahmed Glaucoma Valve Implantation for Uveitic Glaucoma Secondary to Behçet Disease.

    Science.gov (United States)

    Yakin, Mehmet; Eksioglu, Umit; Sungur, Gulten; Satana, Banu; Demirok, Gulizar; Ornek, Firdevs

    2017-01-01

    To evaluate short-term to long-term outcomes of Ahmed glaucoma valve (AGV) implantation in the management of uveitic glaucoma (UG) secondary to Behçet disease (BD). A retrospective chart review of 47 eyes of 35 patients with UG secondary to BD who underwent AGV implantation was conducted. Success was defined as having an intraocular pressure (IOP) between 6 and 21 mm Hg with (qualified success) or without (complete success) antiglaucomatous medications and without need for further glaucoma surgery. Mean postoperative follow-up was 57.72±26.13 months. Mean preoperative IOP was 35.40±8.33 mm Hg versus 12.28±2.90 mm Hg at the last follow-up visit (P<0.001). Mean number of preoperative topical antiglaucomatous medications was 2.96±0.29 versus 0.68±1.12 at the last follow-up visit (P<0.001). In all eyes, IOP could be maintained between 6 and 21 mm Hg with or without antiglaucomatous medications during follow-up. The cumulative probability of complete success was 46.8% at 6 months, 40.4% at 12 months, and 35.9% at 36 months, and the cumulative probability of eyes without complication was 53.2% at 6 months, 46.5% at 12 months, and 39.6% at 24 months postoperatively based on Kaplan-Meier survival analysis. No persistent or irreparable complications were observed. This study includes one of the largest series of AGV implantation in the management of UG with the longest follow-up reported. AGV implantation can be considered as a primary surgical option in the management of UG secondary to BD with 100% total success rate (with or without medications).

  19. Short-term follow-up of exercise training program and beta-blocker treatment on quality of life in dogs with naturally acquired chronic mitral valve disease

    Directory of Open Access Journals (Sweden)

    M. Marcondes-Santos

    2015-01-01

    Full Text Available This study aimed to evaluate the effects of carvedilol treatment and a regimen of supervised aerobic exercise training on quality of life and other clinical, echocardiographic, and biochemical variables in a group of client-owned dogs with chronic mitral valve disease (CMVD. Ten healthy dogs (control and 36 CMVD dogs were studied, with the latter group divided into 3 subgroups. In addition to conventional treatment (benazepril, 0.3-0.5 mg/kg once a day, and digoxin, 0.0055 mg/kg twice daily, 13 dogs received exercise training (subgroup I; 10.3±2.1 years, 10 dogs received carvedilol (0.3 mg/kg twice daily and exercise training (subgroup II; 10.8±1.7 years, and 13 dogs received only carvedilol (subgroup III; 10.9±2.1 years. All drugs were administered orally. Clinical, laboratory, and Doppler echocardiographic variables were evaluated at baseline and after 3 and 6 months. Exercise training was conducted from months 3-6. The mean speed rate during training increased for both subgroups I and II (ANOVA, P>0.001, indicating improvement in physical conditioning at the end of the exercise period. Quality of life and functional class was improved for all subgroups at the end of the study. The N-terminal pro-brain natriuretic peptide (NT-proBNP level increased in subgroup I from baseline to 3 months, but remained stable after training introduction (from 3 to 6 months. For subgroups II and III, NT-proBNP levels remained stable during the entire study. No difference was observed for the other variables between the three evaluation periods. The combination of carvedilol or exercise training with conventional treatment in CMVD dogs led to improvements in quality of life and functional class. Therefore, light walking in CMVD dogs must be encouraged.

  20. Effect of pimobendan or benazepril hydrochloride on survival times in dogs with congestive heart failure caused by naturally occurring myxomatous mitral valve disease: the QUEST study.

    Science.gov (United States)

    Häggström, J; Boswood, A; O'Grady, M; Jöns, O; Smith, S; Swift, S; Borgarelli, M; Gavaghan, B; Kresken, J-G; Patteson, M; Ablad, B; Bussadori, C M; Glaus, T; Kovacević, A; Rapp, M; Santilli, R A; Tidholm, A; Eriksson, A; Belanger, M C; Deinert, M; Little, C J L; Kvart, C; French, A; Rønn-Landbo, M; Wess, G; Eggertsdottir, A V; O'Sullivan, M L; Schneider, M; Lombard, C W; Dukes-McEwan, J; Willis, R; Louvet, A; DiFruscia, R

    2008-01-01

    Myxomatous mitral valve disease (MMVD) continues to be an important cause of morbidity and mortality in geriatric dogs despite conventional therapy. Pimobendan in addition to conventional therapy will extend time to sudden cardiac death, euthanasia for cardiac reasons, or treatment failure when compared with conventional therapy plus benazepril in dogs with congestive heart failure (CHF) attributable to MMVD. Two hundred and sixty client-owned dogs in CHF caused by MMVD were recruited from 28 centers in Europe, Canada, and Australia. A prospective single-blinded study with dogs randomized to PO receive pimobendan (0.4-0.6 mg/kg/d) or benazepril hydrochloride (0.25-1.0 mg/kg/d). The primary endpoint was a composite of cardiac death, euthanized for heart failure, or treatment failure. Eight dogs were excluded from analysis. One hundred and twenty-four dogs were randomized to pimobendan and 128 to benazepril. One hundred and ninety dogs reached the primary endpoint; the median time was 188 days (267 days for pimobendan, 140 days for benazepril hazard ratio = 0.688, 95% confidence limits [CL]=0.516-0.916, P= .0099). The benefit of pimobendan persisted after adjusting for all baseline variables. A longer time to reach the endpoint was also associated with being a Cavalier King Charles Spaniel, requiring a lower furosemide dose, and having a higher creatinine concentration. Increases in several indicators of cardiac enlargement (left atrial to aortic root ratio, vertebral heart scale, and percentage increase in left ventricular internal diameter in systole) were associated with a shorter time to endpoint, as was a worse tolerance for exercise. Pimobendan plus conventional therapy prolongs time to sudden death, euthanasia for cardiac reasons, or treatment failure in dogs with CHF caused by MMVD compared with benazepril plus conventional therapy.

  1. Longitudinal analysis of quality of life, clinical, radiographic, echocardiographic, and laboratory variables in dogs with myxomatous mitral valve disease receiving pimobendan or benazepril: the QUEST study.

    Science.gov (United States)

    Häggström, J; Boswood, A; O'Grady, M; Jöns, O; Smith, S; Swift, S; Borgarelli, M; Gavaghan, B; Kresken, J-G; Patteson, M; Åblad, B; Bussadori, C M; Glaus, T; Kovačević, A; Rapp, M; Santilli, R A; Tidholm, A; Eriksson, A; Belanger, M C; Deinert, M; Little, C J L; Kvart, C; French, A; Rønn-Landbo, M; Wess, G; Eggertsdottir, A; Lynne O'Sullivan, M; Schneider, M; Lombard, C W; Dukes-McEwan, J; Willis, R; Louvet, A; DiFruscia, R

    2013-01-01

    Myxomatous mitral valve disease (MMVD) is an important cause of morbidity and mortality in dogs. To compare, throughout the period of follow-up of dogs that had not yet reached the primary endpoint, the longitudinal effects of pimobendan versus benazepril hydrochloride treatment on quality-of-life (QoL) variables, concomitant congestive heart failure (CHF) treatment, and other outcome variables in dogs suffering from CHF secondary to MMVD. A total of 260 dogs in CHF because of MMVD. A prospective single-blinded study with dogs randomized to receive pimobendan (0.4-0.6 mg/kg/day) or benazepril hydrochloride (0.25-1.0 mg/kg/day). Differences in outcome variables and time to intensification of CHF treatment were compared. A total of 124 dogs were randomized to pimobendan and 128 to benazepril. No difference was found between groups in QoL variables during the trial. Time from inclusion to 1st intensification of CHF treatment was longer in the pimobendan group (pimobendan 98 days, IQR 30-276 days versus benazepril 59 days, IQR 11-121 days; P = .0005). Postinclusion, dogs in the pimobendan group had smaller heart size based on VHS score (P = .013) and left ventricular diastolic (P = .035) and systolic (P = .0044) dimensions, higher body temperature (P = .030), serum sodium (P = .0027), and total protein (P = .0003) concentrations, and packed cell volume (P = .030). Incidence of arrhythmias was similar in treatment groups. Pimobendan versus benazepril resulted in similar QoL during the study, but conferred increased time before intensification of CHF treatment. Pimobendan treatment resulted in smaller heart size, higher body temperature, and less retention of free water. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  2. MicroRNAs Clustered within the 14q32 Locus Are Associated with Endothelial Damage and Microparticle Secretion in Bicuspid Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Neus Martínez-Micaelo

    2017-09-01

    Full Text Available Background: We previously described that PECAM+ circulating endothelial microparticles (EMPs are elevated in bicuspid aortic valve (BAV disease as a manifestation of endothelial damage. In this study, we hypothesized that this endothelial damage, is functionally related to the secretion of a specific pattern of EMP-associated miRNAs.Methods: We used a bioinformatics approach to correlate the PECAM+ EMP levels with the miRNA expression profile in plasma in healthy individuals and BAV patients (n = 36. In addition, using the miRNAs that were significantly associated with PECAM+ EMP levels, we inferred a miRNA co-expression network using a Gaussian graphical modeling approach to identify highly co-expressed miRNAs or miRNA clusters whose expression could functionally regulate endothelial damage.Results: We identified a co-expression network composed of 131 miRNAs whose circulating expression was significantly associated with PECAM+ EMP levels. Using a topological analysis, we found that miR-494 was the most important hub within the co-expression network. Furthermore, through positional gene enrichment analysis, we identified a cluster of 19 highly co-expressed miRNAs, including miR-494, that was located in the 14q32 locus on chromosome 14 (p = 1.9 × 10−7. We evaluated the putative biological role of this miRNA cluster by determining the biological significance of the genes targeted by the cluster using functional enrichment analysis. We found that this cluster was involved in the regulation of genes with various functions, specifically the “cellular nitrogen compound metabolic process” (p = 2.34 × 10−145, “immune system process” (p = 2.57 × 10−6, and “extracellular matrix organization” (p = 8.14 × 10−5 gene ontology terms and the “TGF-β signaling pathway” KEGG term (p = 2.59 × 10−8.Conclusions: Using an integrative bioinformatics approach, we identified the circulating miRNA expression profile associated with

  3. MicroRNAs Clustered within the 14q32 Locus Are Associated with Endothelial Damage and Microparticle Secretion in Bicuspid Aortic Valve Disease

    Science.gov (United States)

    Martínez-Micaelo, Neus; Beltrán-Debón, Raúl; Aragonés, Gerard; Faiges, Marta; Alegret, Josep M.

    2017-01-01

    Background: We previously described that PECAM+ circulating endothelial microparticles (EMPs) are elevated in bicuspid aortic valve (BAV) disease as a manifestation of endothelial damage. In this study, we hypothesized that this endothelial damage, is functionally related to the secretion of a specific pattern of EMP-associated miRNAs. Methods: We used a bioinformatics approach to correlate the PECAM+ EMP levels with the miRNA expression profile in plasma in healthy individuals and BAV patients (n = 36). In addition, using the miRNAs that were significantly associated with PECAM+ EMP levels, we inferred a miRNA co-expression network using a Gaussian graphical modeling approach to identify highly co-expressed miRNAs or miRNA clusters whose expression could functionally regulate endothelial damage. Results: We identified a co-expression network composed of 131 miRNAs whose circulating expression was significantly associated with PECAM+ EMP levels. Using a topological analysis, we found that miR-494 was the most important hub within the co-expression network. Furthermore, through positional gene enrichment analysis, we identified a cluster of 19 highly co-expressed miRNAs, including miR-494, that was located in the 14q32 locus on chromosome 14 (p = 1.9 × 10−7). We evaluated the putative biological role of this miRNA cluster by determining the biological significance of the genes targeted by the cluster using functional enrichment analysis. We found that this cluster was involved in the regulation of genes with various functions, specifically the “cellular nitrogen compound metabolic process” (p = 2.34 × 10−145), “immune system process” (p = 2.57 × 10−6), and “extracellular matrix organization” (p = 8.14 × 10−5) gene ontology terms and the “TGF-β signaling pathway” KEGG term (p = 2.59 × 10−8). Conclusions: Using an integrative bioinformatics approach, we identified the circulating miRNA expression profile associated with secreted PECAM

  4. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    patients with valvular heart disease). Endorsed by the Society of Cardiovascular. Anesthesiologists, Society for Cardiovascular. Angiography and Interventions, and Society of. Thoracic Surgeons. J Am Coll Cardiol. 2008;52(13):e1-142. 5. Elkayam U, Bitar F. Valvular heart disease and pregnancy. Part II: prosthetic valves.

  5. Bentall and De Bono surgery for correction of valve and ascending aortic disease: long-term results.

    Science.gov (United States)

    Silva, Virgílio Figueiredo; Real, Daniel Sundfeld Spiga; Branco, João Nelson Rodrigues; Catani, Roberto; Kim, Hyong Chun; Buffolo, Enio; Fonseca, José Honório de Almeida Palma da

    2008-01-01

    A retrospective study was performed in a series of consecutive patients who underwent a Bentall and De Bono procedure. Data were removed of medical records and follow-up data were obtained from clinical records and direct contact with patients. A total of 39 patients were studied between January 1996 and December 2005. The median age was 47 years (range 14-70). There were 33 males and six females. Eleven (25.5%) patients presented Marfan syndrome and one (2.5%) Turner syndrome. Nineteen (48.5%) patients had hypertension, eight (20.5%) had history of smoking, six (15.5%) had history of alcoholism, eight (20.5%) had dyslipidemia, two (5.0%) had diabetes and one (2.56%) had myocardial infarct previously. Twenty-eight (72%) patients were in II-III NYHA class in the moment of the surgery. Annulo-aortic ecstasy was present in 14 (35.9%) patients and aortic aneurysms in 16 (41%). The median time in intensive care unit was 8.79 days with range 2-23 days. Four (10.0%) patients underwent an emergency operation and 35 (90%) elective. The overall hospital mortality was 5% (2/39). The event-free survival is 94.87% at 1 year and 84.61% at in 5 and 10. The median time of follow-up was 46.5 months (range 14-120 months). The Bentall and De Bono technique obtained excellent results in the short-term and long-term, which support the continued use of the compositive graft technique as the preferred method of treatment for patients with aortic root disease. Our findings confirm the current literature data.

  6. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...

  7. The structure and material composition of ossified aortic valves identified using a set of scientific methods

    Science.gov (United States)

    Zeman, Antonín; Šmíd, Michal; Havelcová, Martina; Coufalová, Lucie; Kučková, Štěpánka; Velčovská, Martina; Hynek, Radovan

    2013-11-01

    Degenerative aortic stenosis has become a common and dangerous disease in recent decades. This disease leads to the mineralization of aortic valves, their gradual thickening and loss of functionality. We studied the detailed assessment of the proportion and composition of inorganic and organic components in the ossified aortic valve, using a set of analytical methods applied in science: polarized light microscopy, scanning electron microscopy, X-ray fluorescence, X-ray diffraction, gas chromatography/mass spectrometry and liquid chromatography-tandem mass spectrometry. The sample valves showed the occurrence of phosphorus and calcium in the form of phosphate and calcium carbonate, hydroxyapatite, fluorapatite and hydroxy-fluorapatite, with varying content of inorganic components from 65 to 90 wt%, and with phased development of degenerative disability. The outer layers of the plaque contained an organic component with peptide bonds, fatty acids, proteins and cholesterol. The results show a correlation between the formation of fluorapatite in aortic valves and in other parts of the human bodies, associated with the formation of bones.

  8. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  10. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  11. Imaging of aortic valve dynamics in 4D OCT

    Directory of Open Access Journals (Sweden)

    Schnabel Christian

    2015-09-01

    Full Text Available The mechanical components of the heart, especially the valves and leaflets, are enormous stressed during lifetime. Therefore, those structures undergo different pathophysiological tissue transformations which affect cardiac output and in consequence living comfort of affected patients. These changes may lead to calcific aortic valve stenosis (AVS, the major heart valve disease in humans. The knowledge about changes of the dynamic behaviour during the course of this disease and the possibility of early stage diagnosis is of particular interest and could lead to the development of new treatment strategies and drug based options of prevention or therapy. 4D optical coherence tomography (OCT in combination with high-speed video microscopy were applied to characterize dynamic behaviour of the murine aortic valve and to characterize dynamic properties during artificial stimulation. We present a promising tool to investigate the aortic valve dynamics in an ex vivo disease model with a high spatial and temporal resolution using a multimodal imaging setup.

  12. Prior oral conditions in patients undergoing heart valve surgery.

    Science.gov (United States)

    Silvestre, Francisco-Javier; Gil-Raga, Irene; Martinez-Herrera, Mayte; Lauritano, Dorina; Silvestre-Rangil, Javier

    2017-11-01

    Patients scheduled for heart valve surgery should be free of any oral infectious disorders that might pose a risk in the postoperative period. Few studies have been made on the dental conditions of such patients prior to surgery. The present study describes the most frequent prior oral diseases in this population group. A prospective, observational case-control study was designed involving 60 patients (30 with heart valve disease and 30 controls, with a mean age of 71 years in both groups). A dental exploration was carried out, with calculation of the DMFT (decayed, missing and filled teeth) index and recording of the periodontal parameters (plaque index, gingival bleeding index, periodontal pocket depth, and attachment loss). The oral mucosa was also examined, and panoramic X-rays were used to identify possible intrabony lesions. Significant differences in bacterial plaque index were observed between the two groups ( p <0.05), with higher scores in the patients with valve disease. Probing depth and the presence of moderate pockets were also greater in the patients with valve disease than among the controls ( p <0.01). Sixty percent of the patients with valve disease presented periodontitis. Patients scheduled for heart valve surgery should be examined for possible active periodontitis before the operation. Those individuals found to have periodontal disease should receive adequate periodontal treatment before heart surgery. Key words: Valve disease, aortic, mitral, heart surgery, periodontitis.

  13. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Should patients with Björk-Shiley valves undergo prophylactic replacement?

    Science.gov (United States)

    Birkmeyer, J D; Marrin, C A; O'Connor, G T

    1992-08-29

    About 85,000 patients have undergone replacement of diseased heart valves with prosthetic Björk-Shiley convexo-concave (CC) valves. These valves are prone to fracture of the outlet strut, which leads to acute valve failure that is usually fatal. Should patients with these valves undergo prophylactic replacement to avoid fracture? The incidence of strut fracture varies between 0% and 1.5% per year, depending on valve opening angle (60 degrees or 70 degrees), diameter (less than 29 mm or greater than or equal to 29 mm), and location (aortic or mitral). Other factors include the patient's life expectancy and the expected morbidity and mortality associated with reoperation. We have used decision analysis to identify the patients most likely to benefit from prophylactic reoperation. The incidence of outlet strut fracture was estimated from the data of three large studies on CC valves, and stratified by opening angle, diameter, and location. A Markov decision analysis model was used to estimate life expectancy for patients undergoing prophylactic valve replacement and for those not undergoing reoperation. Prophylactic valve replacement does not benefit patients with CC valves that have low strut fracture risks (60 degrees aortic valves and less than 29 mm, 60 degrees mitral valves). For most patients with CC valves that have high strut fracture risks (greater than or equal to 29 mm, 70 degrees CC), prophylactic valve replacement increases life expectancy. However, elderly patients with such valves benefit from prophylactic reoperation only if the risk of operative mortality is low. Patient age and operative risk are most important in recommendations for patients with CC valves that have intermediate strut fracture risks (less than 29 mm, 70 degrees valves and greater than or equal to 29 mm, 60 degrees mitral valves). For all patients and their doctors facing the difficult decision on whether to replace CC valves, individual estimates of operative mortality risk that

  15. Haemodynamic improvement of older, previously replaced mechanical mitral valves by removal of the subvalvular pannus in redo cardiac surgery.

    Science.gov (United States)

    Kim, Jong Hun; Kim, Tae Youn; Choi, Jong Bum; Kuh, Ja Hong

    2017-01-01

    Patients requiring redo cardiac surgery for diseased heart valves other than mitral valves may show increased pressure gradients and reduced valve areas of previously placed mechanical mitral valves due to subvalvular pannus formation. We treated four women who had mechanical mitral valves inserted greater than or equal to 20 years earlier and who presented with circular pannus that protruded into the lower margin of the valve ring but did not impede leaflet motion. Pannus removal improved the haemodynamic function of the mitral valve. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  17. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  18. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  19. Piezogenic pedal papules with mitral valve prolapse

    Directory of Open Access Journals (Sweden)

    Cihan Altin

    2016-01-01

    Full Text Available Piezogenic pedal papules (PPP are herniations of subcutaneous adipose tissue into the dermis. PPP are skin-colored to yellowish papules and nodules on lateral surfaces of feet that typically become apparent when the patient stands flat on his/her feet. Some connective tissue diseases and syndromes have been reported in association with PPP. Mitral valve prolapse (MVP is a myxomatous degeneration of the mitral valve, characterized by the displacement of an abnormally thickened mitral valve leaflet into the left atrium during systole. MVP may be isolated or part of a heritable connective tissue disorder. PPP, which is generally considered as an isolated lesion, might be also a predictor of some cardiac diseases associated with connective tissue abnormalities such as MVP. A detailed systemic investigation including cardiac examination should be done in patients with PPP. Since in the literature, there are no case reports of association of PPP with MVP, we report these cases.

  20. A high performance magnetorheological valve with a meandering flow path

    International Nuclear Information System (INIS)

    Imaduddin, Fitrian; Amri Mazlan, Saiful; Azizi Abdul Rahman, Mohd; Zamzuri, Hairi; Ubaidillah; Ichwan, Burhanuddin

    2014-01-01

    The huge developments in the field of magnetorheological (MR) fluid-based devices will have a great influence on the future of mechatronic applications due to the ease of interfacing between electronic controls and the mechanical components that they provide. Among various MR fluid-based devices, an MR valve would be particularly significant for the development of other devices, if it could be successfully achieved. One of the most challenging obstacles to MR valve development is the difficulty of achieving device miniaturization while, at the same time, improving the achievable performance. This study demonstrates a novel design for an MR valve, using the meandering flow path approach in order to increase the effective area so that the MR fluid can be regulated within a small-sized valve. The meandering flow path is formed by combining multiple annular, radial and orifice flow channels. In order to analyze the valve performance, a mathematical model of the proposed MR valve is derived and combined with numerical simulation using the finite element method, with the intention of predicting the achievable pressure drop that can be generated by the valve. The predicted MR valve performances are then experimentally evaluated using an oscillation-disturbed bypass hydraulic cylinder. The simulation results show that the proposed MR valve design could yield substantial pressure drop improvement, which is confirmed by the experiment

  1. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  2. MEPR versus EEPR valves in open supermarket refrigerated display cabinets

    International Nuclear Information System (INIS)

    Tahir, A.; Bansal, P.K.

    2005-01-01

    This paper presents the comparative experimental field performance of mechanical evaporator pressure regulating valves (MEPR) and electronic evaporator pressure regulating valves (EEPR) under the identical operating conditions of supermarket open multi-deck refrigerated display cabinets. The main goal of the supermarket refrigeration system design is to keep the displayed product at the required constant temperature, while minimising the cooling load to increase the overall energy efficiency of the system. Field tests have shown that the electronic evaporator pressure valve has a significant effect on improving the cabinet temperature and reducing the rate of frost formation on the evaporator coils with subsequent improvements in the air curtain strength

  3. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  4. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  5. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Dry product valve

    International Nuclear Information System (INIS)

    Greaves, James D.

    1984-01-01

    This invention provides a system for delivering particulate radioactive or other toxic wastes to a container in which they can be solidified. The system includes a set of valves that prevent the escape of dusty materials to the atmosphere

  7. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  8. Valve for gas centrifuges

    Science.gov (United States)

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  9. Coanda effect in valves

    Directory of Open Access Journals (Sweden)

    Uruba Václav

    2017-01-01

    Full Text Available Coanda effect takes place in flow within valves diffuser for certain conditions. The valve plug in half-closed position forms wall-jet, which could be stable or instable, depending on geometry and other conditions. This phenomenon was subject of experimental study using time-resolved PIV technique. For the acquired data analysis the special spatio-temporal methods have been used.

  10. Degenerative processes in bioprosthetic mitral valves in juvenile pigs

    Directory of Open Access Journals (Sweden)

    Pedersen Torben B

    2011-05-01

    Full Text Available Abstract Background Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthetic valve complications in the mitral position in juvenile pigs. Materials The study material comprised eight, 5-month old, 60-kg pigs. All pigs received a size 27, glutaraldehyde-treated, stented, Carpentier-Edwards S.A.V. mitral valve prosthesis. After six months, echocardiography was performed, and the valves explanted for gross examination, high resolution X-ray, and histological evaluation. Results Five pigs survived the follow-up period. Preexplant echocardiography revealed a median peak and mean velocity of 1.61 m/s (range: 1.17-2.00 and 1.20 (SD = ±0.25, respectively, and a median peak and mean pressure difference of 10.42 mmHg (range: 5.83-16.55 and 6.51 mmHg (SD = ±2.57, respectively. Gross examination showed minor thrombotic depositions at two commissures in two valves and at all three commissures in three valves. High resolution X-ray imaging revealed different degrees of calcification in all explanted valves, primarily in the commissural and belly areas. In all valves, histological evaluation demonstrated various degrees of fibrous sheath formation, limited immunological infiltration, and no overgrowth of host endothelium. Conclusions Bioprosthetic glutaraldehyde-treated mitral valves can be implanted into the mitral position in pigs and function after 6 months. Echocardiographic data, calcification, and histological examinations were comparable to results obtained in sheep models and human demonstrating the suitability of the porcine model.

  11. Patient-specific pediatric silicone heart valve models based on 3D ultrasound

    Science.gov (United States)

    Ilina, Anna; Lasso, Andras; Jolley, Matthew A.; Wohler, Brittany; Nguyen, Alex; Scanlan, Adam; Baum, Zachary; McGowan, Frank; Fichtinger, Gabor

    2017-03-01

    PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons' feedback.

  12. THE PROGNOSIS IN TRANSCATHETER AORTIC VALVE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    T. E. Imaev

    2016-01-01

    Full Text Available Aim. To study the effect of transcatheter aortic valve implantation (TAVI, performed by different types of prostheses and various surgical access, on the prognosis of patients with critical aortic stenosis and comorbidities.Material and methods. Patients (n=130 that had consistently performed 80 TAVI by Edwards valve transfemoral (n=50 and transapical (n=30 access, as well as 50 transcatheter aortic valve replacement by CoreValve system were included into the study. Complications including perioperative mortality, total 30-day mortality, as well as post-hospital mortality were registered during aortic valve replacement, immediately after surgery, before the expiry of 30 days. Mean follow-up was 2.2 years (range 0.2 to 5.2 years.Results. Hospital mortality was on average 6.9%. 121 patients had been discharged from the department after the surgery. The number of deaths in the post-hospital period was 14.8%. Valve type and the type of access had no effect on post-hospital mortality. Men died more than 2.5 times often than women, regardless of age. Atrioventricular block, pacemaker implantation, and history of chronic obstructive pulmonary disease were the most significant prognostic factors. An important role of minor stroke and renal failure should be noted. Mortality did not depend on the surgical access or valve type. All parameters characterizing the intervention were significantly associated with mortality, both during and after surgery. The proportion of survivors at the end of the first year of observation using Corvalve system was 86.9%, Edwards valve by transfemoral access - 88% and Edwards valve by transapical access – 85.4% (insignificant differences for all groups, p>0.05. Two-year survival was 77.5%, 82.5% and 82.7%, respectively (also insignificant differences for all groups, p>0.05.Conclusion. TAVI is the method of choice, reasonable alternative approach for surgical valve replacement in patients with high surgical risk, although

  13. Bacterial Infection Potato Tuber Soft Rot Disease Detection Based on Electronic Nose

    Directory of Open Access Journals (Sweden)

    Chang Zhiyong

    2017-11-01

    Full Text Available Soft rot is a severe bacterial disease of potatoes, and soft rot infection can cause significant economic losses during the storage period of potatoes. In this study, potato soft rot was selected as the research object, and a type of potato tuber soft rot disease early detection method based on the electronic nose technology was proposed. An optimized bionic electronic nose gas chamber and a scientific and reasonable sampling device were designed to detect a change in volatile substances of the infected soft rot disease of potato tuber. The infection of soft rot disease in potato tuber samples was detected and identified by using the RBF NN algorithm and SVM algorithm. The results revealed that the proposed bionic electronic nose system can be utilized for early detection of potato tuber soft rot disease. Through comparison and analysis, the recognition rate using the SVM algorithm reached up to 89.7%, and the results were superior to the RBF NN algorithm.

  14. Left-sided native valve Staphylococcus aureus endocarditis

    NARCIS (Netherlands)

    Slabbekoorn, M.; Horlings, H. M.; van der Meer, J. T. M.; Windhausen, A.; Van der Sloot, J. A. P.; Lagrand, W. K.

    2010-01-01

    Despite improved diagnostic tools and expanded treatment options, left-sided native valve endocarditis caused by Staphylococcus aureus infection remains a serious and destructive disease. The high morbidity and mortality, however, can be reduced by early recognition, correct diagnosis, and

  15. Potential Applications and Limitations of Electronic Nose Devices for Plant Disease Diagnosis

    Directory of Open Access Journals (Sweden)

    Antonio Cellini

    2017-11-01

    Full Text Available Electronic nose technology has recently been applied to the detection of several plant diseases and pests, with promising results. However, in spite of its numerous advantages, including operational simplicity, non-destructivity, and bulk sampling, drawbacks include a low sensitivity and specificity in comparison with microbiological and molecular methods. A critical review of the use of an electronic nose for plant disease diagnosis and pest detection is presented, describing the instrumental and procedural advances of sensorial analysis, for the improvement of discrimination between healthy and infected or infested plants. In conclusion, the use of electronic nose technology is suggested to assist, direct, and optimise traditionally adopted diagnostic techniques.

  16. Sickle cell anemia and mitral valve replacement. Case report.

    Science.gov (United States)

    Bomfim, V; Ribeiro, A; Gouvea, F; Pereira, J; Björk, V

    1989-01-01

    An 8-year-old black boy with sickle cell disease and severe hemolytic anemia crisis (95% hemoglobin S) also had mitral incompetence due to rheumatic valve disease. A 27 mm monostrut Björk-Shiley valve prosthesis was implanted after partial exchange transfusions had reduced the hemoglobin S to less than 40%. High-flow normothermic perfusion was used during extracorporeal circulation, with care taken to avoid hypoxia and acidosis. Postoperative recovery was uneventful.

  17. Methods of estimation of mitral valve regurgitation for the cardiac surgeon

    Directory of Open Access Journals (Sweden)

    Baikoussis Nikolaos G

    2009-07-01

    Full Text Available Abstract Mitral valve regurgitation is a relatively common and important heart valve lesion in clinical practice and adequate assessment is fundamental to decision on management, repair or replacement. Disease localised to the posterior mitral valve leaflet or focal involvement of the anterior mitral valve leaflet is most amenable to mitral valve repair, whereas patients with extensive involvement of the anterior leaflet or incomplete closure of the valve are more suitable for valve replacement. Echocardiography is the recognized investigation of choice for heart valve disease evaluation and assessment. However, the technique is depended on operator experience and on patient's hemodynamic profile, and may not always give optimal diagnostic views of mitral valve dysfunction. Cardiac catheterization is related to common complications of an interventional procedure and needs a hemodynamic laboratory. Cardiac magnetic resonance (MRI seems to be a useful tool which gives details about mitral valve anatomy, precise point of valve damage, as well as the quantity of regurgitation. Finally, despite of its higher cost, cardiac MRI using cine images with optimized spatial and temporal resolution can also resolve mitral valve leaflet structural motion, and can reliably estimate the grade of regurgitation.

  18. Porcine Tricuspid Valve Anatomy and Human Compatibility: Relevance for Preclinical Validation of Novel Valve Interventions.

    Science.gov (United States)

    Waziri, Farhad; Lyager Nielsen, Sten; Michael Hasenkam, John

    2016-09-01

    Tricuspid regurgitation may be a precursor for heart failure, reduced functional capacity, and poor survival. A human compatible experimental model is required to understand the pathophysiology of the tricuspid valve disease as a basis for validating novel tricuspid valve interventions before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin-fixed porcine hearts obtained from Danish Landrace pigs (body weight 80 kg). All valvular dimensions were compared with human data acquired from literature sources. No difference was seen in the tricuspid annulus circumference between porcine and human hearts (13.0 ± 1.2 cm versus 13.5 ± 1.5 cm; p = NS), or in valve area (5.7 ± 1.6 cm2 versus 5.6 ± 1.0 cm2; p = NS). The majority of chordae types exhibited a larger chordal length and thickness in human hearts compared to porcine hearts. In both species, the anterior papillary muscle (PM) was larger than other PMs in the right ventricle, but muscle length varied greatly (range: 5.2-40.3 mm) and was significantly different in pigs and in humans (12.2 ± 3.2 mm versus 19.2 mm; p human hearts.

  19. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  20. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  1. How to use and integrate bioinformatics tools to compare proteomic data from distinct conditions? A tutorial using the pathological similarities between Aortic Valve Stenosis and Coronary Artery Disease as a case-study.

    Science.gov (United States)

    Trindade, Fábio; Ferreira, Rita; Magalhães, Beatriz; Leite-Moreira, Adelino; Falcão-Pires, Inês; Vitorino, Rui

    2018-01-16

    Nowadays we are surrounded by a plethora of bioinformatics tools, powerful enough to deal with the large amounts of data arising from proteomic studies, but whose application is sometimes hard to find. Therefore, we used a specific clinical problem - to discriminate pathophysiology and potential biomarkers between two similar cardiovascular diseases, aortic valve stenosis (AVS) and coronary artery disease (CAD) - to make a step-by-step guide through four bioinformatics tools: STRING, DisGeNET, Cytoscape and ClueGO. Proteome data was collected from articles available on PubMed centered on proteomic studies enrolling subjects with AVS or CAD. Through the analysis of gene ontology provided by STRING and ClueGO we could find specific biological phenomena associated with AVS, such as down-regulation of elastic fiber assembly, and with CAD, such as up-regulation of plasminogen activation. Moreover, through Cytoscape and DisGeNET we could pinpoint surrogate markers either for AVS (e.g. popeye domain containing protein 2 and 28S ribosomal protein S36, mitochondrial) or for CAD (e.g. ankyrin repeat and SOCS box protein 7) which deserve future validation. Data recycling and integration as well as research orientation are among the main advantages of resorting to bioinformatics analysis, hence these tutorials can be of great convenience for proteomics investigators. As we saw for aortic valve stenosis and coronary artery disease, it can be of great relevance to perform preliminary bioinformatics analysis with already published proteomics data. It not only saves us time in the lab (avoiding work duplication) as it points out new hypothesis to explain the phenotypical presentation of the diseases as well as new surrogate markers with clinical relevance, deserving future scrutiny. These essential steps can be easily overcome if one follows the steps proposed in our tutorial for STRING, DisGeNET, Cytoscape and ClueGO utilization. Copyright © 2017 Elsevier B.V. All rights

  2. Hydrodynamic characterization of a passive shape memory alloy valve

    International Nuclear Information System (INIS)

    Waddell, A M; Punch, J; Stafford, J; Jeffers, N

    2014-01-01

    Next generation high-performance electronics will have large heat fluxes (>10 2 W/cm 2 ) and an alternative approach to traditional air cooling is required. An attractive solution is micro-channel cooling and micro-valves will be required for refined flow control in the supporting micro-fluidic systems. A NiTi Shape Memory Alloy (SMA) micro-valve design was hydrodynamically characterized in this work to obtain the valve loss coefficient (K) from pressure measurements. The hydrodynamic characterization was important as in the flow regime of the micro-fluidic system K is sensitive to Reynolds number (Re) and geometry. Static replicas of the SMA valve geometry were studied for low Reynolds numbers (110 – 220) in a 1x1 mm CSA miniature channel. The loss coefficients were found to be sensitive to flow rate and decreased rapidly with an increase in Re. The SMA valve was compared to a similar gate micro-valve and loss across both valves was of the same order of magnitude. The valve loss coefficients obtained in this work are important parameters in the modeling and design of micro-fluidic cooling systems.

  3. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  4. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  5. Features of mitral valve prolapse in young patients

    Directory of Open Access Journals (Sweden)

    M. A. Kuznetsova

    2015-06-01

    Full Text Available Due to the significant increase of complications in young patients with mitral valve prolapse detection of this disease is important. Aim. With the aim of studying the features of mitral valve prolapse 135 persons with mitral valve prolapse at the age of 18–25 years were examined. Methods and results. The features of mitral valve prolapsed were studied with echocardiography, electrocardiography, cardiointervalography. It was established that mitral valve prolapse (MVP in young age had different clinical picture. Patients with MVP 1 degree mainly had autonomic instability, and with 2 degree - mostly signs of connective tissue dysplasia. Conclusion. The presence of MVP is associated with abnormalities of the rhythm and conductivity: 1 degree - sinus tachycardia; the 2nd - sinus arrhythmia, signs of left ventricular hypertrophy and impaired repolarization of the myocardium.

  6. Aortic valve ochronosis: a rare manifestation of alkaptonuria.

    Science.gov (United States)

    Steger, Christina Maria

    2011-07-28

    Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed.

  7. Constraints on Biological Mechanism from Disease Comorbidity Using Electronic Medical Records and Database of Genetic Variants.

    Directory of Open Access Journals (Sweden)

    Steven C Bagley

    2016-04-01

    Full Text Available Patterns of disease co-occurrence that deviate from statistical independence may represent important constraints on biological mechanism, which sometimes can be explained by shared genetics. In this work we study the relationship between disease co-occurrence and commonly shared genetic architecture of disease. Records of pairs of diseases were combined from two different electronic medical systems (Columbia, Stanford, and compared to a large database of published disease-associated genetic variants (VARIMED; data on 35 disorders were available across all three sources, which include medical records for over 1.2 million patients and variants from over 17,000 publications. Based on the sources in which they appeared, disease pairs were categorized as having predominant clinical, genetic, or both kinds of manifestations. Confounding effects of age on disease incidence were controlled for by only comparing diseases when they fall in the same cluster of similarly shaped incidence patterns. We find that disease pairs that are overrepresented in both electronic medical record systems and in VARIMED come from two main disease classes, autoimmune and neuropsychiatric. We furthermore identify specific genes that are shared within these disease groups.

  8. Comprehensive update on the new indications for transcatheter aortic valve replacement in the latest 2017 European guidelines for the management of valvular heart disease

    Science.gov (United States)

    Thonghong, Tasalak; De Backer, Ole; Søndergaard, Lars

    2018-01-01

    New European guidelines on the management of valvular heart disease—supported by the European Society of Cardiology (ESC) and European Association of CardioThoracic Surgery (EACTS)—were recently published. Although these guidelines are very comprehensive, these typically are not very inviting to read. In this document, we aimed to distil all the information about transcatheter aortic valve replacement (TAVR) in the new 2017 ESC/EACTS guidelines to the essential and give additional comments on the position of TAVR in 2017. PMID:29531767

  9. Disease surveillance among newly arriving refugees and immigrants--Electronic Disease Notification System, United States, 2009.

    Science.gov (United States)

    Lee, Deborah; Philen, Rossanne; Wang, Zanju; McSpadden, Pamela; Posey, Drew L; Ortega, Luis S; Weinberg, Michelle S; Brown, Clive; Zhou, Weigong; Painter, John A

    2013-11-15

    Approximately 450,000 legal permanent immigrants and 75,000 refugees enter the United States annually after receiving required medical examinations by overseas panel physicians (physicians who follow the CDC medical screening guidelines provided to the U.S. Department of State). CDC has the regulatory responsibility for preventing the introduction, transmission, and spread of communicable diseases into the United States as well as for developing the guidelines, known as technical instructions, for the overseas medical examinations. Other conditions that are not infectious might preclude an immigrant or refugee from entering the United States and also are reported as part of the medical examination. After arrival in the United States, all refugees are recommended to obtain a medical assessment by a health-care provider or a health department within 30 days. In addition, immigrants with certain medical conditions such as noninfectious tuberculosis at the time of the original medical examination are recommended to be evaluated after arrival to ensure that appropriate prevention or treatment measures are instituted. Health departments need timely and accurate notifications of newly arriving immigrants, refugees, and persons with other visa types to facilitate these evaluations. Notifications for all newly arriving refugees (with or without medical conditions) and immigrants with medical conditions are provided by CDC's Electronic Disease Notification (EDN) system. This is the first report describing EDN. This report summarizes notifications by the EDN system during January-December 2009. The EDN system is a centralized electronic reporting system that collects health information on newly arriving refugees and immigrants with Class A and Class B medical conditions. Class A conditions render applicants inadmissible and require a waiver for entry; Class B conditions are admissible but might require treatment or follow-up. Information in the EDN system is used to notify

  10. Clinical case of acute chord rupture of the mitral valve posterior leaflet in older patient with comorbidities

    OpenAIRE

    Zhuravlyova, L.; Lopina, N.; Kuznetsov, I.; Lopin, D.; Kramarenko, I.; Sumanova, I.

    2015-01-01

    The article describes the etiologic role of various factors such as chronic rheumatic heart disease, bacterial endocarditis, aortic valve stenosis, hypertension, coronary heart disease, including acute myocardial infarction, degenerative disease of the valves, connective tissue diseases, chest trauma, systemic lupus erythematosus, con-genital heart disease which leading to the mitral valve chords rupture, gives the current classification of the nosology and also features of manifestation and ...

  11. Surface Modification using Plasma treatments and Adhesion Peptide for Durable Tissue-Engineered Heart Valves

    International Nuclear Information System (INIS)

    Jung, Young mee; Kim, Soo Hyun

    2010-01-01

    Artificial heart valves are used in valvular heart diseases, but these valves have disadvantages that they cannot grow, repair and remodel. In current study, the strategies to development of in vitro cultured functional tissue by tissue engineering is available to heart valve disease. In the point of using viable autolougous cells, tissue engineered heart valves have some advantage to include that they can repair, remodel, and grow. Because heart valve is placed under the strong shear stress condition by pumping of heart, the durability of tissue-engineered heart valves is now questionable. The purpose of the study is to evaluate of the durability of tissue engineered heart valve with surface modified scaffolds under hemodynamic conditions

  12. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  13. A symmetric safety valve

    International Nuclear Information System (INIS)

    Burtraw, Dallas; Palmer, Karen; Kahn, Danny

    2010-01-01

    How to set policy in the presence of uncertainty has been central in debates over climate policy. Concern about costs has motivated the proposal for a cap-and-trade program for carbon dioxide, with a 'safety valve' that would mitigate against spikes in the cost of emission reductions by introducing additional emission allowances into the market when marginal costs rise above the specified allowance price level. We find two significant problems, both stemming from the asymmetry of an instrument that mitigates only against a price increase. One is that most important examples of price volatility in cap-and-trade programs have occurred not when prices spiked, but instead when allowance prices collapsed. Second, a single-sided safety valve may have unintended consequences for investment. We illustrate that a symmetric safety valve provides environmental and welfare improvements relative to the conventional one-sided approach.

  14. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    Science.gov (United States)

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  16. Lack of segregation of a Marfan-like phenotype associating marfanoie habitus and mitral valve disease with fibrillin gene on chromosome 15

    Energy Technology Data Exchange (ETDEWEB)

    VanMaldergen, L.; Hilbert, P.; Gillerot, Y. [Institut de Morphologie Pathologique, Loverval (Belgium)] [and others

    1994-09-01

    Apart from typical Marfan syndrome (MS), several Marfan-like conditions are known. One of those is the MASS syndrome (Mitral involvement, Aortic dilatation, Skin and Skeletal abnormalities) defined by Pyeritz et al. Among these, a dominantly inherited mitral valve prolapse with marfanoid habitus have also been reported. Until now, except for a Marfan-like condition described by Boileau et al., all Marfan families are linked to fib 15. A large Belgian pedigree with 25 affected patients among 62 at risk subjects spanning four generations is described. A syndrome including marfanoid skeletal dysplasia (tall stature, dolichostenomelia, arachnodactyly, pectus carinatum joint dislocation), prolapse and/or myxomatous degeneration of the mitral valve, but without aortic dilatation of eye involvement was observed. Although the phenotype fulfills Berlin diagnostic criteria for MS, it closely resembles MASS syndrome. Preliminary linkage results show discordance aggregation insertion in the fib 15 gene, as evaluated by intragenic microsatellite fib 15. Since Dietz et al. described a similar patient with fib 15 gene, we suggest that this variant of Marfan syndrome is genetically heterogeneous and caused by mutations, some of which are allelic to classical Marfan syndrome plus a subtype, some of which are not. Linkage studies are under way to further characterize the gene involved in the present family.

  17. Valve spindle gland

    International Nuclear Information System (INIS)

    Burda, Z.; Harazim, A.; Kerlin, K.

    1979-01-01

    A gland is proposed of the valve spindle designed for radioactive or otherwise harmful media, such as in nuclear power plant primary circuits. The gland is installed in the valve cover and consists of a primary and a secondary part and of a gland case partitioning the gland space into two chambers. The bottom face of the gland case is provided with a double-sided collar for controlling the elements of the bottom primary gland while the top face is provided with a removable flange. (M.S.)

  18. Characterizing nanoscale topography of the aortic heart valve basement membrane for tissue engineering heart valve scaffold design.

    Science.gov (United States)

    Brody, Sarah; Anilkumar, Thapasimuthu; Liliensiek, Sara; Last, Julie A; Murphy, Christopher J; Pandit, Abhay

    2006-02-01

    A fully effective prosthetic heart valve has not yet been developed. A successful tissue-engineered valve prosthetic must contain a scaffold that fully supports valve endothelial cell function. Recently, topographic features of scaffolds have been shown to influence the behavior of a variety of cell types and should be considered in rational scaffold design and fabrication. The basement membrane of the aortic valve endothelium provides important parameters for tissue engineering scaffold design. This study presents a quantitative characterization of the topographic features of the native aortic valve endothelial basement membrane; topographical features were measured, and quantitative data were generated using scanning electron microscopy (SEM), atomic force microscopy (AFM), transmission electron microscopy (TEM), and light microscopy. Optimal conditions for basement membrane isolation were established. Histological, immunohistochemical, and TEM analyses following decellularization confirmed basement membrane integrity. SEM and AFM photomicrographs of isolated basement membrane were captured and quantitatively analyzed. The basement membrane of the aortic valve has a rich, felt-like, 3-D nanoscale topography, consisting of pores, fibers, and elevations. All features measured were in the sub-100 nm range. No statistical difference was found between the fibrosal and ventricular surfaces of the cusp. These data provide a rational starting point for the design of extracellular scaffolds with nanoscale topographic features that mimic those found in the native aortic heart valve basement membrane.

  19. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  20. New insights into valve-related intramural and intracellular bacterial diversity in infective endocarditis.

    Science.gov (United States)

    Oberbach, Andreas; Schlichting, Nadine; Feder, Stefan; Lehmann, Stefanie; Kullnick, Yvonne; Buschmann, Tilo; Blumert, Conny; Horn, Friedemann; Neuhaus, Jochen; Neujahr, Ralph; Bagaev, Erik; Hagl, Christian; Pichlmaier, Maximilian; Rodloff, Arne Christian; Gräber, Sandra; Kirsch, Katharina; Sandri, Marcus; Kumbhari, Vivek; Behzadi, Armirhossein; Behzadi, Amirali; Correia, Joao Carlos; Mohr, Friedrich Wilhelm; Friedrich, Maik

    2017-01-01

    In infective endocarditis (IE), a severe inflammatory disease of the endocardium with an unchanged incidence and mortality rate over the past decades, only 1% of the cases have been described as polymicrobial infections based on microbiological approaches. The aim of this study was to identify potential biodiversity of bacterial species from infected native and prosthetic valves. Furthermore, we compared the ultrastructural micro-environments to detect the localization and distribution patterns of pathogens in IE. Using next-generation sequencing (NGS) of 16S rDNA, which allows analysis of the entire bacterial community within a single sample, we investigated the biodiversity of infectious bacterial species from resected native and prosthetic valves in a clinical cohort of 8 IE patients. Furthermore, we investigated the ultrastructural infected valve micro-environment by focused ion beam scanning electron microscopy (FIB-SEM). Biodiversity was detected in 7 of 8 resected heart valves. This comprised 13 bacterial genera and 16 species. In addition to 11 pathogens already described as being IE related, 5 bacterial species were identified as having a novel association. In contrast, valve and blood culture-based diagnosis revealed only 4 species from 3 bacterial genera and did not show any relevant antibiotic resistance. The antibiotics chosen on this basis for treatment, however, did not cover the bacterial spectra identified by our amplicon sequencing analysis in 4 of 8 cases. In addition to intramural distribution patterns of infective bacteria, intracellular localization with evidence of bacterial immune escape mechanisms was identified. The high frequency of polymicrobial infections, pathogen diversity, and intracellular persistence of common IE-causing bacteria may provide clues to help explain the persistent and devastating mortality rate observed for IE. Improved bacterial diagnosis by 16S rDNA NGS that increases the ability to tailor antibiotic therapy may

  1. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  2. The association of incidentally detected heart valve calcification with future cardiovascular events

    OpenAIRE

    Gondrie, Martijn J. A.; van der Graaf, Yolanda; Jacobs, Peter C.; Oen, Ay L.; Mali, Willem P. Th. M.

    2010-01-01

    Objectives This study aims to investigate the prognostic value of incidental aortic valve calcification (AVC), mitral valve calcification (MVC) and mitral annular calcification (MAC) for cardiovascular events and non-rheumatic valve disease in particular on routine diagnostic chest CT. Methods The study followed a case-cohort design. 10410 patients undergoing chest CT were followed for a median period of 17 months. Patients referred for cardiovascular disease were excluded. A random sample of...

  3. Oil Stiction in Fast Switching Annular Seat Valves for Digital Displacement Fluid Power Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    Digital Displacement (DD) fluid power machines utilizes electronically controlled seat valves connected to pressure chambers to obtain variable displacement with high operational efficiency and high bandwidth. To achieve high efficiency, fast valve switching is essential and all aspects related...... to the dynamic behaviour of the seat valves must be considered to optimize the machine efficiency. A significant effect influencing the valves switching performance is the presence of oil stiction when separating the contact surfaces in valve opening movement. This oil stiction force is limited by cavitation...... for low pressure levels, e.g. valves connected to the low pressure manifold, however for valves operated at higher pressure levels, the oil stiction force is dominating when the separating surfaces are close to contact. This paper presents an analytic solution to the oil stiction force for annular seat...

  4. Crystalline Ultrastructures, Inflammatory Elements, and Neoangiogenesis Are Present in Inconspicuous Aortic Valve Tissue

    Directory of Open Access Journals (Sweden)

    P. Dorfmüller

    2010-01-01

    Full Text Available Morbidity from calcific aortic valve disease (CAVD is increasing. Recent studies suggest early reversible changes involving inflammation and neoangiogenesis. We hypothesized that microcalcifications, chemokines, and growth factors are present in unaffected regions of calcific aortic valves. We studied aortic valves from 4 patients with CAVD and from 1 control, using immunohistochemistry, scanning electron microscopy, and infrared spectrography. We revealed clusters of capillary neovessels in calcified (ECC, to a lesser extent in noncalcified (ECN areas. Endothelial cells proved constant expression of SDF-1 in ECC, ECN, and endothelial cells from valvular surface (ECS. Its receptor CXCR4 was expressed in ECC. IL-6 expression correlated with CXCR4 staining and presence of lymphocytes. VEGF was expressed by ECS, its receptor by ECC and ECN. Crystalline ultrastructures were found on the surface of histologically noncalcified areas (HNCAs, spectrography revealed calcium hydroxylapatite. Our results demonstrate that crystalline ultrastructures are present in HNCAs, undergoing neoangiogenesis in an inflammatory context. These alterations could be an early witness of disease and an opening to therapy.

  5. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly r...

  6. Poppet valve tester

    Science.gov (United States)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  7. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  8. Blocked Urethral Valves

    Science.gov (United States)

    ... if any damage has occurred to the upper urinary tract. Your pediatrician will consult with a pediatric nephrologist (kidney specialist) or nurologist, who may recommend surgery to remove the obstructing valves and prevent further infection or damage to the kidneys or urinary system. ...

  9. Correlation between left ventricular diastolic function before and after valve replacement surgery and myocardial ultrastructural changes in patients with left ventricular volume-overloaded valvular heart diseases

    International Nuclear Information System (INIS)

    Okada, Tomiro

    1993-01-01

    Left ventricular (LV) diastolic functions in 23 patients with aortic regurgitation (AR) and 22 patients with mitral regurgitation (MR) were evaluated by gated blood pool scintigraphy. LV myocardial biopsy was performed during open heart surgery, and LV myocardial ultrastructural changes were evaluated by electron microscope. Correlation between LV diastolic function and myocardial ultrastructural changes was examined. It was suggested that preoperative LV diastolic dysfunction occurred earlier than LV systolic dysfunction in patients with AR and MR. LV early diastolic dysfunction was especially significant in patients with AR. LV systolic function was significantly improved postoperatively compared with LV diastolic function in patients with AR and MR. It was suggested that LV interstitial fibrosis caused LV diastolic dysfunction in patients with AR and MR, and insufficiency of myocardial thickening as compensation in patients with MR. It was presumed that LV diastolic dysfunction was irreversible in patients with AR and MR in the distant postoperative period due to persistence of the preoperative myocardial ultrastructural change, e.g., interstitial fibrosis. These LV diastolic indices measured by gated pool scintigraphy were useful in predicting LV ultrastructural changes and postoperative LV dysfunction in patients with LV volume-overloaded valvular heart disease. (author)

  10. Identification and Progression of Heart Disease Risk Factors in Diabetic Patients from Longitudinal Electronic Health Records

    Directory of Open Access Journals (Sweden)

    Jitendra Jonnagaddala

    2015-01-01

    Full Text Available Heart disease is the leading cause of death worldwide. Therefore, assessing the risk of its occurrence is a crucial step in predicting serious cardiac events. Identifying heart disease risk factors and tracking their progression is a preliminary step in heart disease risk assessment. A large number of studies have reported the use of risk factor data collected prospectively. Electronic health record systems are a great resource of the required risk factor data. Unfortunately, most of the valuable information on risk factor data is buried in the form of unstructured clinical notes in electronic health records. In this study, we present an information extraction system to extract related information on heart disease risk factors from unstructured clinical notes using a hybrid approach. The hybrid approach employs both machine learning and rule-based clinical text mining techniques. The developed system achieved an overall microaveraged F-score of 0.8302.

  11. Three-dimensional echocardiographic assessment of the repaired mitral valve.

    Science.gov (United States)

    Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun

    2014-02-01

    This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Plastik på trikuspidalklappen (Tricuspid valve annuloplasty. The neglected valve)

    DEFF Research Database (Denmark)

    Pedersen, Thais A L; Wierup, Per; Pedersen, Lia Mendes

    2010-01-01

    INTRODUCTION: Tricuspid valve regurgitation (TVR) is often secondary to left-sided or congenital heart disease (CHD). Surgical correction of TVR is indicated when the primary abnormalities require operation. MATERIAL AND METHODS: Retrospective analysis of all 50 patients (mean age: 65 years (rang...

  13. Tricuspid valve endocarditis

    Science.gov (United States)

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  14. Echocardiographic pattern and severity of valve dysfunction in ...

    African Journals Online (AJOL)

    Background: Rheumatic heart disease (RHD) is the commonest acquired heart disease in children worldwide but in Uganda, data is scarce regarding its morbidity and mortality. The disease has a progressive course and patients usually require valve repair/replacement in the future. Objectives:To describe the frequency of ...

  15. The dilemma of complicated shunt valves: How to identify patients with posthemorrhagic hydrocephalus after aneurysmatic subarachnoid hemorrhage who will benefit from a simple valve?

    Directory of Open Access Journals (Sweden)

    Christian von der Brelie

    2016-01-01

    Full Text Available Background: Sophisticated shunt valves provide the possibility of pressure adjustment and antisiphon control but have a higher probability of valve dysfunction especially in a posthemorrhagic setting. The aim of the present study is to analyze the clinical outcome of patients with shunt dependent posthemorrhagic hydrocephalus after aneurysmatic subarachnoid hemorrhage (SAH in order to identify patients who would benefit from a simple differential pressure valve. Methods: From 2000 to 2013, 547 patients with aneurysmatic SAH were treated at our institution, 114 underwent ventricular shunt placement (21.1%. 47 patients with available pre- and post-operative computed tomography scans, and an available follow-up of minimum 6 months were included. In order to measure the survival time which a nonprogrammable differential pressure valve would have had in an individual patient we defined the initial equalized shunt survival time (IESS. IESS is the time until surgical revisions of fixed differential pressure or flow-regulated valves for the treatment of over- or under-drainage as well as re-programming of adjustable valves due to over- or under-drainage. Results: Twenty patients were treated with fixed differential pressure valves, 15 patients were treated with flow-regulated valves, and 12 underwent ventriculoperitoneal (VP shunt placement with differential pressure valves assisted by a gravitational unit. Patients who reacted with remarkable changes of the ventricular width after the insertion of external ventricular drainage (EVD, before shunt placement, showed a significantly longer IESS. Conclusions: Decline of the ventricular width after EVD placement was a predictor for successful VP shunt therapy in the later course of disease. Possibly, this could allow identifying patients who benefit from a simple differential pressure valve or a flow-regulated valve, and thus could possibly avoid valve-associated complications of a programmable valve in the

  16. Lactococcus garvieae Endocarditis on a Prosthetic Biological Aortic Valve.

    Science.gov (United States)

    Tsur, A; Slutzki, T; Flusser, D

    2015-09-01

    Lactococcus garvieae (LG) endocarditis is a rare disease in humans. There are only about 16 reported cases in the world. We report a 76-year-old male patient with LG endocarditis. In depth interview with the patient revealed that 2 weeks prior to admission, he had eaten sushi containing raw fish. Unlike many of the other infections reported, which were on a native mitral valve, our patient's vegetation was on a prosthetic aortic valve. © 2014 Blackwell Verlag GmbH.

  17. Exercise-based cardiac rehabilitation after heart valve surgery

    DEFF Research Database (Denmark)

    Hansen, T B; Zwisler, Ann-Dorthe; Berg, S K

    2015-01-01

    BACKGROUND: Owing to a lack of evidence, patients undergoing heart valve surgery have been offered exercise-based cardiac rehabilitation (CR) since 2009 based on recommendations for patients with ischaemic heart disease in Denmark. The aim of this study was to investigate the impact of CR...... expensive outpatient visits. Further studies should investigate the benefits of CR to heart valve surgery patients as part of a formal cost-utility analysis....

  18. Defect in mitochondrial functions in damaged human mitral valve

    OpenAIRE

    Shinde, Santosh; Kumar, Pawan; Mishra, Kaushala; Patil, Neela

    2006-01-01

    Mitochondrial diseases are a heterogeneous group of disorders in which a primary mitochondrial dysfunction is proven by morphological, biochemical, and genetic examinations. The mitral valve has important function in the regulation of blood flow from one chamber to another. Often, the mitral valve becomes abnormal with age, in Rheumatic fever or it is abnormal from birth (Congenital) or it can be destroyed by infection i.e. bacterial endocarditis and needs replacement. Myocardial function dep...

  19. Missed aortic valve endocarditis resulting in complete atrioventricular block and redo mechanical valve replacement.

    Science.gov (United States)

    Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex

    2017-08-03

    Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  1. Prognostic value of heart valve calcifications for cardiovascular events in a lung cancer screening population

    NARCIS (Netherlands)

    Willemink, Martin J.; Takx, Richard A. P.; Isgum, I; de Koning, Harry J.; Oudkerk, Matthijs; Mali, Willem P. Th. M.; Budde, Ricardo P. J.; Leiner, Tim; Vliegenthart, Rozemarijn; de Jong, Pim A.

    To assess the prognostic value of aortic valve and mitral valve/annulus calcifications for cardiovascular events in heavily smoking men without a history of cardiovascular disease. Heavily smoking men without a cardiovascular disease history who underwent non-contrast-enhanced low-radiation-dose

  2. Prognostic value of heart valve calcifications for cardiovascular events in a lung cancer screening population

    NARCIS (Netherlands)

    M.J. Willemink (Martin J.); R.A.P. Takx (Richard A.); I. Isgum (Ivana); H.J. de Koning (Harry); M. Oudkerk (Matthijs); W.P. Mali (Willem); R.P.J. Budde (Ricardo); I. Leiner (Tim); R. Vliegenthart (Rozemarijn); P.A. de Jong (Pim)

    2015-01-01

    textabstractTo assess the prognostic value of aortic valve and mitral valve/annulus calcifications for cardiovascular events in heavily smoking men without a history of cardiovascular disease. Heavily smoking men without a cardiovascular disease history who underwent non-contrast-enhanced

  3. Moderate exercise does not increase the severity of mitral regurgitation due to mitral valve prolapse

    DEFF Research Database (Denmark)

    Pecini, Redi; Dalsgaard, Morten; Møller, Daniel Vega

    2010-01-01

    Mitral regurgitation (MR) secondary to ischemic heart disease (IHD) increases during exercise. We tested the hypothesis that the same is also true for MR due to mitral valve prolapse (MVP).......Mitral regurgitation (MR) secondary to ischemic heart disease (IHD) increases during exercise. We tested the hypothesis that the same is also true for MR due to mitral valve prolapse (MVP)....

  4. A Typical Immune T/B Subset Profile Characterizes Bicuspid Aortic Valve: In an Old Status?

    Directory of Open Access Journals (Sweden)

    Carmela R. Balistreri

    2018-01-01

    Full Text Available Bicuspid valve disease is associated with the development of thoracic aortic aneurysm. The molecular mechanisms underlying this association still need to be clarified. Here, we evaluated the circulating levels of T and B lymphocyte subsets associated with the development of vascular diseases in patients with bicuspid aortic valve or tricuspid aortic valve with and without thoracic aortic aneurysm. We unveiled that the circulating levels of the MAIT, CD4+IL−17A+, and NKT T cell subsets were significantly reduced in bicuspid valve disease cases, when compared to tricuspid aortic valve cases in either the presence or the absence of thoracic aortic aneurysm. Among patients with tricuspid aortic valve, these cells were higher in those also affected by thoracic aortic aneurysm. Similar data were obtained by examining CD19+ B cells, naïve B cells (IgD+CD27−, memory unswitched B cells (IgD+CD27+, memory switched B cells (IgD−CD27+, and double-negative B cells (DN (IgD−CD27−. These cells resulted to be lower in subjects with bicuspid valve disease with respect to patients with tricuspid aortic valve. In whole, our data indicate that patients with bicuspid valve disease show a quantitative reduction of T and B lymphocyte cell subsets. Future studies are encouraged to understand the molecular mechanisms underlying this observation and its pathophysiological significance.

  5. Discovering disease associations by integrating electronic clinical data and medical literature.

    Directory of Open Access Journals (Sweden)

    Antony B Holmes

    Full Text Available Electronic health record (EHR systems offer an exceptional opportunity for studying many diseases and their associated medical conditions within a population. The increasing number of clinical record entries that have become available electronically provides access to rich, large sets of patients' longitudinal medical information. By integrating and comparing relations found in the EHRs with those already reported in the literature, we are able to verify existing and to identify rare or novel associations. Of particular interest is the identification of rare disease co-morbidities, where the small numbers of diagnosed patients make robust statistical analysis difficult. Here, we introduce ADAMS, an Application for Discovering Disease Associations using Multiple Sources, which contains various statistical and language processing operations. We apply ADAMS to the New York-Presbyterian Hospital's EHR to combine the information from the relational diagnosis tables and textual discharge summaries with those from PubMed and Wikipedia in order to investigate the co-morbidities of the rare diseases Kaposi sarcoma, toxoplasmosis, and Kawasaki disease. In addition to finding well-known characteristics of diseases, ADAMS can identify rare or previously unreported associations. In particular, we report a statistically significant association between Kawasaki disease and diagnosis of autistic disorder.

  6. Contribution of Electronic Medical Records to the Management of Rare Diseases

    Directory of Open Access Journals (Sweden)

    Dominique Bremond-Gignac

    2015-01-01

    Full Text Available Purpose. Electronic health record systems provide great opportunity to study most diseases. Objective of this study was to determine whether electronic medical records (EMR in ophthalmology contribute to management of rare eye diseases, isolated or in syndromes. Study was designed to identify and collect patients’ data with ophthalmology-specific EMR. Methods. Ophthalmology-specific EMR software (Softalmo software Corilus was used to acquire ophthalmological ocular consultation data from patients with five rare eye diseases. The rare eye diseases and data were selected and collected regarding expertise of eye center. Results. A total of 135,206 outpatient consultations were performed between 2011 and 2014 in our medical center specialized in rare eye diseases. The search software identified 29 congenital aniridia, 6 Axenfeld/Rieger syndrome, 11 BEPS, 3 Nanophthalmos, and 3 Rubinstein-Taybi syndrome. Discussion. EMR provides advantages for medical care. The use of ophthalmology-specific EMR is reliable and can contribute to a comprehensive ocular visual phenotype useful for clinical research. Conclusion. Routinely EMR acquired with specific software dedicated to ophthalmology provides sufficient detail for rare diseases. These software-collected data appear useful for creating patient cohorts and recording ocular examination, avoiding the time-consuming analysis of paper records and investigation, in a University Hospital linked to a National Reference Rare Center Disease.

  7. Contribution of Electronic Medical Records to the Management of Rare Diseases.

    Science.gov (United States)

    Bremond-Gignac, Dominique; Lewandowski, Elisabeth; Copin, Henri

    2015-01-01

    Electronic health record systems provide great opportunity to study most diseases. Objective of this study was to determine whether electronic medical records (EMR) in ophthalmology contribute to management of rare eye diseases, isolated or in syndromes. Study was designed to identify and collect patients' data with ophthalmology-specific EMR. Ophthalmology-specific EMR software (Softalmo software Corilus) was used to acquire ophthalmological ocular consultation data from patients with five rare eye diseases. The rare eye diseases and data were selected and collected regarding expertise of eye center. A total of 135,206 outpatient consultations were performed between 2011 and 2014 in our medical center specialized in rare eye diseases. The search software identified 29 congenital aniridia, 6 Axenfeld/Rieger syndrome, 11 BEPS, 3 Nanophthalmos, and 3 Rubinstein-Taybi syndrome. EMR provides advantages for medical care. The use of ophthalmology-specific EMR is reliable and can contribute to a comprehensive ocular visual phenotype useful for clinical research. Routinely EMR acquired with specific software dedicated to ophthalmology provides sufficient detail for rare diseases. These software-collected data appear useful for creating patient cohorts and recording ocular examination, avoiding the time-consuming analysis of paper records and investigation, in a University Hospital linked to a National Reference Rare Center Disease.

  8. Myofibroblasts in interstitial lung diseases show diverse electron microscopic and invasive features.

    Science.gov (United States)

    Karvonen, Henna M; Lehtonen, Siri T; Sormunen, Raija T; Harju, Terttu H; Lappi-Blanco, Elisa; Bloigu, Risto S; Kaarteenaho, Riitta L

    2012-09-01

    The characteristic features of myofibroblasts in various lung disorders are poorly understood. We have evaluated the ultrastructure and invasive capacities of myofibroblasts cultured from small volumes of diagnostic bronchoalveolar lavage (BAL) fluid samples from patients with different types of lung diseases. Cells were cultured from samples of BAL fluid collected from 51 patients that had undergone bronchoscopy and BAL for diagnostic purposes. The cells were visualized by transmission electron microscopy and immunoelectron microscopy to achieve ultrastructural localization of alpha-smooth muscle actin (α-SMA) and fibronectin. The levels of α-SMA protein and mRNA and fibronectin mRNA were measured by western blot and quantitative real-time reverse transcriptase polymerase chain reaction. The invasive capacities of the cells were evaluated. The cultured cells were either fibroblasts or myofibroblasts. The structure of the fibronexus, and the amounts of intracellular actin, extracellular fibronectin and cell junctions of myofibroblasts varied in different diseases. In electron and immunoelectron microscopy, cells cultured from interstitial lung diseases (ILDs) expressed more actin filaments and α-SMA than normal lung. The invasive capacity of the cells obtained from patients with idiopathic pulmonary fibrosis was higher than that from patients with other type of ILDs. Cells expressing more actin filaments had a higher invasion capacity. It is concluded that electron and immunoelectron microscopic studies of myofibroblasts can reveal differential features in various diseases. An analysis of myofibroblasts cultured from diagnostic BAL fluid samples may represent a new kind of tool for diagnostics and research into lung diseases.

  9. Utilizing Dental Electronic Health Records Data to Predict Risk for Periodontal Disease.

    Science.gov (United States)

    Thyvalikakath, Thankam P; Padman, Rema; Vyawahare, Karnali; Darade, Pratiksha; Paranjape, Rhucha

    2015-01-01

    Periodontal disease is a major cause for tooth loss and adversely affects individuals' oral health and quality of life. Research shows its potential association with systemic diseases like diabetes and cardiovascular disease, and social habits such as smoking. This study explores mining potential risk factors from dental electronic health records to predict and display patients' contextualized risk for periodontal disease. We retrieved relevant risk factors from structured and unstructured data on 2,370 patients who underwent comprehensive oral examinations at the Indiana University School of Dentistry, Indianapolis, IN, USA. Predicting overall risk and displaying relationships between risk factors and their influence on the patient's oral and general health can be a powerful educational and disease management tool for patients and clinicians at the point of care.

  10. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  11. Capturing structured, pulmonary disease-specific data elements in electronic health records.

    Science.gov (United States)

    Gronkiewicz, Cynthia; Diamond, Edward J; French, Kim D; Christodouleas, John; Gabriel, Peter E

    2015-04-01

    Electronic health records (EHRs) have the potential to improve health-care quality by allowing providers to make better decisions at the point of care based on electronically aggregated data and by facilitating clinical research. These goals are easier to achieve when key, disease-specific clinical information is documented as structured data elements (SDEs) that computers can understand and process, rather than as free-text/natural-language narrative. This article reviews the benefits of capturing disease-specific SDEs. It highlights several design and implementation considerations, including the impact on efficiency and expressivity of clinical documentation and the importance of adhering to data standards when available. Pulmonary disease-specific examples of collection instruments are provided from two commonly used commercial EHRs. Future developments that can leverage SDEs to improve clinical quality and research are discussed.

  12. Aortic valve-sparing surgery in Marfan syndrome.

    Science.gov (United States)

    Nachum, Eyal; Shinfeld, Amichay; Kogan, Alexander; Preisman, Sergey; Levin, Shany; Raanani, Ehud

    2013-08-01

    Patients with Marfan syndrome are referred for cardiac surgery due to root aneurysm with or without aortic valve regurgitation. Because these patients are young and frequently present with normal-appearing aortic cusps, valve sparing is often recommended. However, due to the genetic nature of the disease, the durability of such surgery remains uncertain. Between February 2004 and June 2012, 100 patients in our department suffering from aortic aneurysm with aortic valve regurgitation underwent elective aortic valve-sparing surgery. Of them, 30 had Marfan syndrome, were significantly younger (30 +/- 13 vs. 53 +/- 16 years), and had a higher percentage of root aneurysm, compared with ascending aorta aneurysm in their non-Marfan counterparts. We evaluated the safety, durability, clinical and echocardiographic mid-term results of these patients. While no early deaths were reported in either group, there were a few major early complications in both groups. At follow-up (reaching 8 years with a mean of 34 +/- 26 months) there were no late deaths, and few major late complications in the Marfan group. Altogether, 96% and 78% of the patients were in New York Heart Association functional class I-II in the Marfan and non-Marfan groups respectively. None of the Marfan patients needed reoperation on the aortic valve. Freedom from recurrent aortic valve regurgitation > 3+ was 94% in the Marfan patients. Aortic valve-sparing surgery in Marfan symdrome patients is safe and yields good mid-term clinical outcomes.

  13. Calcific aortic valve damage as a risk factor for cardiovascular events

    International Nuclear Information System (INIS)

    Wasilewski, Jarosław; Mirota, Kryspin; Wilczek, Krzysztof; Głowacki, Jan; Poloński, Lech

    2012-01-01

    Aortic valve calcification (AVC) is a common disease of the elderly. It is a progressive disease ranging from mild valve thickening to severe calcification with aortic valve stenosis. Risk factors for AVC are similar to those for atherosclerosis: age, gender, hypercholesterolemia, diabetes, hypertension, smoking and renal failure. AVC shares many similarities to atherosclerosis, including inflammatory cells and calcium deposits, and correlates with coronary plaque burden. Presence of AVC is associated with increased risk of adverse cardiovascular events. The objective for this review is to discuss the clinical features, natural history and prognostic significance of aortic valve calcifications, including mechanical and hemodynamic factors of flow distribution

  14. Valve radio and audio repair handbook

    CERN Document Server

    MILLER, CHAS

    2000-01-01

    This book is not only an essential read for every professional working with antique radio and gramophone equipment, but also dealers, collectors and valve technology enthusiasts the world over. The emphasis is firmly on the practicalities of repairing and restoring, so technical content is kept to a minimum, and always explained in a way that can be followed by readers with no background in electronics. Those who have a good grounding in electronics, but wish to learn more about the practical aspects, will benefit from the emphasis given to hands-on repair work, covering mechanical as

  15. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  16. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  17. Aortic valve calcification and mild tricuspid regurgitation but no clinical heart disease after 8 years of dopamine agonist therapy for prolactinoma

    NARCIS (Netherlands)

    Kars, Marleen; Delgado, Victoria; Holman, Eduard R.; Feelders, Richard A.; Smit, Johannes W. A.; Romijn, Johannes A.; Bax, Jeroen J.; Pereira, Alberto M.

    2008-01-01

    Treatment with ergot-derived dopamine agonists, pergolide, and cabergoline has been associated with an increased frequency of valvular heart disease in Parkinson's disease. The aim of the present study was to assess the prevalence of valvular heart disease in patients treated with dopamine agonists

  18. Aortic valve calcification and mild tricuspid regurgitation but no clinical heart disease after 8 years of dopamine agonist therapy for prolactinoma

    NARCIS (Netherlands)

    M. Kars; V. Delgado (Victoria); E.R. Holman (Eduard); R.A. Feelders (Richard); J.W.A. Smit (Jan); J.A. Romijn (Johannes); J.J. Bax (Jeroen); A.M. Pereira (Alberto)

    2008-01-01

    textabstractObjective: Treatment with ergot-derived dopamine agonists, pergolide, and cabergoline has been associated with an increased frequency of valvular heart disease in Parkinson's disease. The aim of the present study was to assess the prevalence of valvular heart disease in patients treated

  19. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  20. Automatic fire hydrant valve development

    International Nuclear Information System (INIS)

    Drumheller, K.

    1976-01-01

    The development of a remotely-controlled valve to operate a fire hydrant is described. Assembled from off-the-shelf components, the prototype illustrates that a valve light enough to be handled by one man is possible. However, it does not have the ruggedness or reliability needed for actual fire-fighting operations. Preliminary testing by City of Tacoma fire department personnel indicates that the valve may indeed contribute significantly to fire-fighting efficiency

  1. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  2. Neurotrophin 3 upregulates proliferation and collagen production in human aortic valve interstitial cells: a potential role in aortic valve sclerosis.

    Science.gov (United States)

    Yao, Qingzhou; Song, Rui; Ao, Lihua; Cleveland, Joseph C; Fullerton, David A; Meng, Xianzhong

    2017-06-01

    Calcific aortic valve disease (CAVD) is a leading cardiovascular disorder in the elderly. Diseased aortic valves are characterized by sclerosis (fibrosis) and nodular calcification. Sclerosis, an early pathological change, is caused by aortic valve interstitial cell (AVIC) proliferation and overproduction of extracellular matrix (ECM) proteins. However, the mechanism of aortic valve sclerosis remains unclear. Recently, we observed that diseased human aortic valves overexpress growth factor neurotrophin 3 (NT3). In the present study, we tested the hypothesis that NT3 is a profibrogenic factor to human AVICs. AVICs isolated from normal human aortic valves were cultured in M199 growth medium and treated with recombinant human NT3 (0.10 µg/ml). An exposure to NT3 induced AVIC proliferation, upregulated the production of collagen and matrix metalloproteinase (MMP), and augmented collagen deposition. These changes were abolished by inhibition of the Trk receptors. NT3 induced Akt phosphorylation and increased cyclin D1 protein levels in a Trk receptor-dependent fashion. Inhibition of Akt abrogated the effect of NT3 on cyclin D1 production. Furthermore, inhibition of either Akt or cyclin D1 suppressed NT3-induced cellular proliferation and MMP-9 and collagen production, as well as collagen deposition. Thus, NT3 upregulates cellular proliferation, ECM protein production, and collagen deposition in human AVICs. It exerts these effects through the Trk-Akt-cyclin D1 cascade. NT3 is a profibrogenic mediator in human aortic valve, and overproduction of NT3 by aortic valve tissue may contribute to the mechanism of valvular sclerosis. Copyright © 2017 the American Physiological Society.

  3. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    Science.gov (United States)

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  4. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  5. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  6. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  7. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  8. Mitral Valve Surgery in Patients with Systemic Lupus Erythematosus

    Science.gov (United States)

    Hekmat, Manouchehr; Ghorbani, Mohsen; Ghaderi, Hamid; Majidi, Masoud; Beheshti, Mahmood

    2014-01-01

    Valvular heart disease is the common cardiac manifestation of systemic lupus erythematosus (SLE) with a tendency for mitral valve regurgitation. In this study we report a case of mitral valve replacement for mitral stenosis caused by Libman-Sacks endocarditis in the setting of SLE. In addition, we provide a systematic review of the literature on mitral valve surgery in the presence of Libman-Sacks endocarditis because its challenge on surgical options continues. Surgical decision depends on structural involvement of mitral valve and presence of active lupus nephritis and antiphospholipid antibody syndrome. Review of the literature has also shown that outcome is good in most SLE patients who have undergone valvular surgery, but association of antiphospholipid antibody syndrome with SLE has negative impact on the outcome. PMID:25401131

  9. Perceval S aortic valve implantation in an achondroplastic Dwarf

    Directory of Open Access Journals (Sweden)

    Nikolaos G Baikoussis

    2016-01-01

    Full Text Available Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography.

  10. Perceval S aortic valve implantation in an achondroplastic Dwarf.

    Science.gov (United States)

    Baikoussis, Nikolaos G; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis

    2016-01-01

    Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography.

  11. Using electronic patient records to discover disease correlations and stratify patient cohorts.

    Directory of Open Access Journals (Sweden)

    Francisco S Roque

    2011-08-01

    Full Text Available Electronic patient records remain a rather unexplored, but potentially rich data source for discovering correlations between diseases. We describe a general approach for gathering phenotypic descriptions of patients from medical records in a systematic and non-cohort dependent manner. By extracting phenotype information from the free-text in such records we demonstrate that we can extend the information contained in the structured record data, and use it for producing fine-grained patient stratification and disease co-occurrence statistics. The approach uses a dictionary based on the International Classification of Disease ontology and is therefore in principle language independent. As a use case we show how records from a Danish psychiatric hospital lead to the identification of disease correlations, which subsequently can be mapped to systems biology frameworks.

  12. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve Disease

    DEFF Research Database (Denmark)

    Mylotte, Darren; Lefevre, Thierry; Søndergaard, Lars

    2014-01-01

    (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p day device safety, success, and efficacy were noted in 79.1%, 89...

  13. Heart Valve Surgery Recovery and Follow Up

    Science.gov (United States)

    ... Guide: Understanding Your Heart Valve Problem | Spanish Symptom Tracker | Spanish Pre-surgery Checklist | Spanish What Is Heart ... Heart Valves • Heart Valve Problems and Causes • Risks, Signs and Symptoms • Accurate Diagnosis • Treatment Options • Recovery and ...

  14. Treatment of extra-mammary Paget's disease with high energy electron beam

    International Nuclear Information System (INIS)

    Ogawa, Yasuhiro; Kimura, Syuji; Kumano, Machiko; Tsuboi, Yoshitaka; Gose, Kyuhei.

    1979-01-01

    10 patients with extra-mammary Paget's disease were treated with high energy electron beam. 3 were treated surgically before irradiation. They were irradiated with the dose from, 6,000 rad in 40 fractions in 53 days to 9,900 rad in 66 fractions in 90 days. 3 recurred within 2 years and 1 recurred after 4.8 years and 1 recurred after 5 years. The early recurrence was observed around the irradiated field, while the late recurrence was seen in the irradiated field. A wider area should be irradiated to control this invasive disease. (author)

  15. Using Electronic Patient Records to Discover Disease Correlations and Stratify Patient Cohorts

    DEFF Research Database (Denmark)

    Roque, Francisco S.; Jensen, Peter B.; Schmock, Henriette

    2011-01-01

    Electronic patient records remain a rather unexplored, but potentially rich data source for discovering correlations between diseases. We describe a general approach for gathering phenotypic descriptions of patients from medical records in a systematic and non-cohort dependent manner. By extracting...... phenotype information from the free-text in such records we demonstrate that we can extend the information contained in the structured record data, and use it for producing fine-grained patient stratification and disease co-occurrence statistics. The approach uses a dictionary based on the International...

  16. Role of CT in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Suchá, D.

    2016-01-01

    Valvular heart disease accounts for a substantial part of the cardiovascular disease worldwide with an estimated prevalence of 2.5% in the Western population aged <65 years and over 13% in the population aged >75 years. Surgical prosthetic heart valve (PHV) replacement is the indicated therapy for

  17. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  18. Supercritical Carbon Dioxide–Based Sterilization of Decellularized Heart Valves

    Directory of Open Access Journals (Sweden)

    Ryan S. Hennessy, MD

    2017-02-01

    Full Text Available Summary: Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid– and supercritical carbon dioxide–treated valves were found to be sterile using histology, microbe culture, and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide–treated valves were higher compared with valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Key Words: decellularized, decontamination, heart valve, tensile properties, tissue engineering

  19. Leveraging electronic health records to support chronic disease management: the need for temporal data views.

    Science.gov (United States)

    Samal, Lipika; Wright, Adam; Wong, Bang T; Linder, Jeffrey A; Bates, David W

    2011-01-01

    The ageing population worldwide is increasingly acquiring multiple chronic diseases. The complex management of chronic diseases could be improved with electronic health records (EHRs) tailored to chronic disease care, but most EHRs in use today do not adequately support longitudinal data management. A key aspect of chronic disease management is that it takes place over long periods, but the way that most EHRs display longitudinal data makes it difficult to trend changes over time and slows providers as they review each patient's unique course. We present five clinical scenarios illustrating longitudinal data needs in complex chronic disease management. These scenarios may function as example cases for software development. For each scenario, we describe and illustrate improvements in temporal data views. Two potential solutions are visualisation for numerical data and disease-oriented text summaries for non-numerical data. We believe that development and widespread implementation of improved temporal data views in EHRs will improve the efficiency and quality of chronic disease management in primary care.

  20. Transcatheter aortic valve implantation and cerebrovascular accidents.

    Science.gov (United States)

    Stortecky, Stefan; Wenaweser, Peter; Windecker, Stephan

    2012-09-01

    Transcatheter aortic valve implantation (TAVI) is an evidence-based treatment alternative for selected high-risk patients with symptomatic severe aortic stenosis as acknowledged in the most recent edition of the ESC Guidelines on Valvular Heart Disease 2012. However, periprocedural complications and in particular cerebrovascular accidents remain a matter of concern. While transcatheter heart valve technology continuously improves and the development of novel and even less invasive implantation techniques is on-going, cerebrovascular events complicating TAVI may abrogate the usual improvement in terms of prognosis and quality of life. This article describes the incidence of cerebrovascular events after cardiovascular procedures, provides an overview of the pathophysiological mechanisms as well as the impact on outcomes and provides some insights into preventive strategies as well as the acute management of these events.

  1. Late presentation of posterior urethral valves.

    Science.gov (United States)

    Jalbani, Imran Khan; Biyabani, Syed Raziuddin

    2014-05-01

    Presence of posterior urethral valves (PUV) is the most common cause of urinary tract obstruction in the male neonate. Late presentation occurs in 10% of cases. We present a case of PUVs in an adult male who presented with history of obstructive lower urinary tract symptoms and hematuria. On evaluation, he was found to have raised serum creatinine level. A voiding cystourethrogram (VCUG) could not be completely performed because of narrowing in the posterior urethra. A rigid urethrocystoscopy was performed at which he was found to have type-I posterior urethral valve which were fulgurated. A repeat uroflowmetry revealed maximum flow rate of 12 ml/second. This case highlights that PUVs is not solely a disease of infancy but may also present late. VCUG is the radiological investigation of choice but the diagnosis may be missed. A urethrocystoscopy is advised if there is a high index of suspicion.

  2. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    mortality were collected. Group analysis by patient geographic distribution and by annular diameter of the prosthesis utilized was conducted. Patients with a manufacturer's labeled prosthesis size > or = 21 mm were assigned to the 'large' aortic size subset, while those with a prosthesis size ... differences in the distribution of either gender or BSA. In the multivariable model, south European patients were seven times more likely to receive a smaller-sized aortic valve (OR = 6.5, 95% CI = 4.82-8.83, p

  3. Tissue engineering of heart valves: in vitro experiences.

    Science.gov (United States)

    Sodian, R; Hoerstrup, S P; Sperling, J S; Daebritz, S H; Martin, D P; Schoen, F J; Vacanti, J P; Mayer, J E

    2000-07-01

    Tissue engineering is a new approach, whereby techniques are being developed to transplant autologous cells onto biodegradable scaffolds to ultimately form new functional tissue in vitro and in vivo. Our laboratory has focused on the tissue engineering of heart valves, and we have fabricated a trileaflet heart valve scaffold from a biodegradable polymer, a polyhydroxyalkanoate. In this experiment we evaluated the suitability of this scaffold material as well as in vitro conditioning to create viable tissue for tissue engineering of a trileaflet heart valve. We constructed a biodegradable and biocompatible trileaflet heart valve scaffold from a porous polyhydroxyalkanoate (Meatabolix Inc, Cambridge, MA). The scaffold consisted of a cylindrical stent (1 x 15 x 20 mm inner diameter) and leaflets (0.3 mm thick), which were attached to the stent by thermal processing techniques. The porous heart valve scaffold (pore size 100 to 240 microm) was seeded with vascular cells grown and expanded from an ovine carotid artery and placed into a pulsatile flow bioreactor for 1, 4, and 8 days. Analysis of the engineered tissue included biochemical examination, enviromental scanning electron microscopy, and histology. It was possible to create a trileaflet heart valve scaffold from polyhydroxyalkanoate, which opened and closed synchronously in a pulsatile flow bioreactor. The cells grew into the pores and formed a confluent layer after incubation and pulsatile flow exposure. The cells were mostly viable and formed connective tissue between the inside and the outside of the porous heart valve scaffold. Additionally, we demonstrated cell proliferation (DNA assay) and the capacity to generate collagen as measured by hydroxyproline assay and movat-stained glycosaminoglycans under in vitro pulsatile flow conditions. Polyhydroxyalkanoates can be used to fabricate a porous, biodegradable heart valve scaffold. The cells appear to be viable and extracellular matrix formation was induced

  4. BNGS B valve packing program

    International Nuclear Information System (INIS)

    Cumming, D.

    1995-01-01

    The Bruce B Valve Packing Program began in 1987. The early history and development were presented at the 1992 International CANDU Maintenance conference. This presentation covers the evolution of the Bruce B Valve Packing Program over the period 1992 to 1995. (author)

  5. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    Science.gov (United States)

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Long-Term Results of Mitral Valve Repair

    Directory of Open Access Journals (Sweden)

    Francisco Diniz Affonso da Costa

    Full Text Available Abstract Introduction: Current guidelines state that patients with severe mitral regurgitation should be treated in reference centers with a high reparability rate, low mortality rate, and durable results. Objective: To analyze our global experience with the treatment of organic mitral regurgitation from various etiologies operated in a single center. Methods: We evaluated all surgically treated patients with organic mitral regurgitation from 2004-2017. Patients were evaluated clinically and by echocardiography every year. We determined early and late survival rates, valve related events and freedom from recurrent mitral regurgitation and tricuspid regurgitation. Valve failure was defined as any mitral regurgitation ≥ moderate degree or the need for reoperation for any reason. Results: Out of 133 patients with organic mitral regurgitation, 125 (93.9% were submitted to valve repair. Mean age was 57±15 years and 52 patients were males. The most common etiologies were degenerative disease (73 patients and rheumatic disease (34 patients. Early mortality was 2.4% and late survival was 84.3% at 10 years, which are similar to the age- and gender-matched general population. Only two patients developed severe mitral regurgitation, and both were reoperated (95.6% at 10 years. Freedom from mitral valve failure was 84.5% at 10 years, with no difference between degenerative and rheumatic valves. Overall, late ≥ moderate tricuspid regurgitation was present in 34% of the patients, being more common in the rheumatic ones. The use of tricuspid annuloplasty abolished this complication. Conclusion: We have demonstrated that mitral regurgitation due to organic mitral valve disease from various etiologies can be surgically treated with a high repair rate, low early mortality and long-term survival that are comparable to the matched general population. Concomitant treatment of atrial fibrillation and tricuspid valve may be important adjuncts to optimize long

  7. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  8. Emerging Trends in Heart Valve Engineering: Part IV. Computational Modeling and Experimental Studies.

    Science.gov (United States)

    Kheradvar, Arash; Groves, Elliott M; Falahatpisheh, Ahmad; Mofrad, Mohammad K; Hamed Alavi, S; Tranquillo, Robert; Dasi, Lakshmi P; Simmons, Craig A; Jane Grande-Allen, K; Goergen, Craig J; Baaijens, Frank; Little, Stephen H; Canic, Suncica; Griffith, Boyce

    2015-10-01

    In this final portion of an extensive review of heart valve engineering, we focus on the computational methods and experimental studies related to heart valves. The discussion begins with a thorough review of computational modeling and the governing equations of fluid and structural interaction. We then move onto multiscale and disease specific modeling. Finally, advanced methods related to in vitro testing of the heart valves are reviewed. This section of the review series is intended to illustrate application of computational methods and experimental studies and their interrelation for studying heart valves.

  9. Bicuspid aortic valve demonstrated with multislice computed tomography - a case report

    International Nuclear Information System (INIS)

    Marzec, M.; Lasek, W.; Serafin, Z.; Laskowska, K.; Swiatkiewicz, I.; Kubica, J.

    2004-01-01

    Bicuspid aortic valve (BAV) is one of the most common congenital heart defects and often coexists with other congenital abnormalities of the heart and great vessels. A standard diagnostic technique for valve imaging is echocardiography. However, suboptimal images may cause a diagnostic problem, especially in obese patients, women and in case of significant valve calcifications. The paper reports a case of a 27-year-old male patient with recurrent chest pain, appearing regardless of exertion. Routine physical examination, laboratory tests and echocardiography were negative. Multislice computed tomography (MSCT) showed normal coronary arteries and bicuspid aortic valve. The diagnostics of bicuspid aortic valve and the diagnostic value of MSCT are discussed. MSCT seems to be an important point in cardiac diagnostic algorithms, being an alternative modality for MR in BAV imaging. The presented case emphasizes the potential of MSCT for the diagnostics of cardiac valve congenital diseases. (author)

  10. Staphylococcus caprae native mitral valve infective endocarditis.

    Science.gov (United States)

    Kwok, T'ng Choong; Poyner, Jennifer; Olson, Ewan; Henriksen, Peter; Koch, Oliver

    2016-10-01

    Staphylococcus caprae is a rare cause of infective endocarditis. Here, we report a case involving the native mitral valve in the absence of an implantable cardiac electronic device. A 76-year-old man presented with a 2 week history of confusion and pyrexia. His past medical history included an open reduction and internal fixation of a humeral fracture 17 years previously, which remained non-united despite further revision 4 years later. There was no history of immunocompromise or farm-animal contact. Two sets of blood culture bottles, more than 12 h apart, were positive for S. caprae . Trans-thoracic echocardiography revealed a 1×1.2 cm vegetation on the mitral valve, with moderate mitral regurgitation. Due to ongoing confusion, he had a magnetic resonance imaging brain scan, which showed a subacute small vessel infarct consistent with a thromboembolic source. A humeral SPECT-CT (single-photon emission computerized tomography-computerized tomography) scan showed no clear evidence of acute osteomyelitis. Surgical vegetectomy and mitral-valve repair were considered to reduce the risk of further systemic embolism and progressive valve infection. However, the potential risks of surgery to this patient led to a decision to pursue a cure with antibiotic therapy alone. He remained well 3 months after discharge, with repeat echocardiography demonstrating a reduction in the size of the vegetation (0.9 cm). Management of this infection was challenging due to its rarity and its unclear progression, complicated by the dilemma surrounding surgical intervention in a patient with a complex medical background.

  11. Spin valve sensor for biomolecular identification: Design, fabrication, and characterization

    Science.gov (United States)

    Li, Guanxiong

    Biomolecular identification, e.g., DNA recognition, has broad applications in biology and medicine such as gene expression analysis, disease diagnosis, and DNA fingerprinting. Therefore, we have been developing a magnetic biodetection technology based on giant magnetoresistive spin valve sensors and magnetic nanoparticle (developed for the magnetic nanoparticle detection, assuming the equivalent average field of magnetic nanoparticles and the coherent rotation of spin valve free layer magnetization. Micromagnetic simulations have also been performed for the spin valve sensors. The analytical model and micromagnetic simulations are found consistent with each other and are in good agreement with experiments. The prototype spin valve sensors have been fabricated at both micron and submicron scales. We demonstrated the detection of a single 2.8-mum magnetic microbead by micron-sized spin valve sensors. Based on polymer-mediated self-assembly and fine lithography, a bilayer lift-off process was developed to deposit magnetic nanoparticles onto the sensor surface in a controlled manner. With the lift-off deposition method, we have successfully demonstrated the room temperature detection of monodisperse 16-nm Fe3O 4 nanoparticles in a quantity from a few tens to several hundreds by submicron spin valve sensors, proving the feasibility of the nanoparticle detection. As desired for quantitative biodetection, a fairly linear dependence of sensor signal on the number of nanoparticles has been confirmed. The initial detection of DNA hybridization events labeled by magnetic nanoparticles further proved the magnetic biodetection concept.

  12. Early Outcomes of Sutureless Aortic Valves

    Directory of Open Access Journals (Sweden)

    Muhammet Onur Hanedan

    2016-06-01

    Full Text Available Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA valves were used. Results: The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7% were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69% died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  13. Early Outcomes of Sutureless Aortic Valves.

    Science.gov (United States)

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-06-01

    In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  14. Automatic prediction of rheumatoid arthritis disease activity from the electronic medical records.

    Directory of Open Access Journals (Sweden)

    Chen Lin

    Full Text Available We aimed to mine the data in the Electronic Medical Record to automatically discover patients' Rheumatoid Arthritis disease activity at discrete rheumatology clinic visits. We cast the problem as a document classification task where the feature space includes concepts from the clinical narrative and lab values as stored in the Electronic Medical Record.The Training Set consisted of 2792 clinical notes and associated lab values. Test Set 1 included 1749 clinical notes and associated lab values. Test Set 2 included 344 clinical notes for which there were no associated lab values. The Apache clinical Text Analysis and Knowledge Extraction System was used to analyze the text and transform it into informative features to be combined with relevant lab values.Experiments over a range of machine learning algorithms and features were conducted. The best performing combination was linear kernel Support Vector Machines with Unified Medical Language System Concept Unique Identifier features with feature selection and lab values. The Area Under the Receiver Operating Characteristic Curve (AUC is 0.831 (σ = 0.0317, statistically significant as compared to two baselines (AUC = 0.758, σ = 0.0291. Algorithms demonstrated superior performance on cases clinically defined as extreme categories of disease activity (Remission and High compared to those defined as intermediate categories (Moderate and Low and included laboratory data on inflammatory markers.Automatic Rheumatoid Arthritis disease activity discovery from Electronic Medical Record data is a learnable task approximating human performance. As a result, this approach might have several research applications, such as the identification of patients for genome-wide pharmacogenetic studies that require large sample sizes with precise definitions of disease activity and response to therapies.

  15. Secreted Klotho Attenuates Inflammation-Associated Aortic Valve Fibrosis in Senescence-Accelerated Mice P1.

    Science.gov (United States)

    Chen, Jianglei; Fan, Jun; Wang, Shirley; Sun, Zhongjie

    2018-05-01

    Senescence-accelerated mice P1 (SAMP1) is an aging model characterized by shortened lifespan and early signs of senescence. Klotho is an aging-suppressor gene. The purpose of this study is to investigate whether in vivo expression of secreted klotho ( Skl ) gene attenuates aortic valve fibrosis in SAMP1 mice. SAMP1 mice and age-matched (AKR/J) control mice were used. SAMP1 mice developed obvious fibrosis in aortic valves, namely fibrotic aortic valve disease. Serum level of Skl was decreased drastically in SAMP1 mice. Expression of MCP-1 (monocyte chemoattractant protein 1), ICAM-1 (intercellular adhesion molecule 1), F4/80, and CD68 was increased in aortic valves of SAMP1 mice, indicating inflammation. An increase in expression of α-smooth muscle actin (myofibroblast marker), transforming growth factorβ-1, and scleraxis (a transcription factor of collagen synthesis) was also found in aortic valves of SAMP1 mice, suggesting that accelerated aging is associated with myofibroblast transition and collagen gene activation. We constructed adeno-associated virus 2 carrying mouse Skl cDNA for in vivo expression of Skl. Skl gene delivery effectively increased serum Skl of SAMP1 mice to the control level. Skl gene delivery inhibited inflammation and myofibroblastic transition in aortic valves and attenuated fibrotic aortic valve disease in SAMP1 mice. It is concluded that senescence-related fibrotic aortic valve disease in SAMP1 mice is associated with a decrease in serum klotho leading to inflammation, including macrophage infiltration and transforming growth factorβ-1/scleraxis-driven myofibroblast differentiation in aortic valves. Restoration of serum Skl levels by adeno-associated virus 2 carrying mouse Skl cDNA effectively suppresses inflammation and myofibroblastic transition and attenuates aortic valve fibrosis. Skl may be a potential therapeutic target for fibrotic aortic valve disease. © 2018 American Heart Association, Inc.

  16. Reoperation for non-structural valvular dysfunction caused by pannus ingrowth in aortic valve prosthesis.

    Science.gov (United States)

    Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk

    2013-07-01

    The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.

  17. Patient experiences of recovery after heart valve replacement: suffering weakness, struggling to resume normality

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Zwisler, Ann-Dorthe; Pedersen, Birthe D.

    2013-01-01

    Heart valve disease is becoming a public health problem due to increasing life expectancy and new treatment methods. Patients are at risk of developing depression, anxiety or post-traumatic stress disorder after heart valve surgery. To better plan proper care, describing and understanding patients...

  18. Genome-wide analysis yields new loci associating with aortic valve stenosis

    DEFF Research Database (Denmark)

    Helgadottir, Anna; Thorleifsson, Gudmar; Gretarsdottir, Solveig

    2018-01-01

    Aortic valve stenosis (AS) is the most common valvular heart disease, and valve replacement is the only definitive treatment. Here we report a large genome-wide association (GWA) study of 2,457 Icelandic AS cases and 349,342 controls with a follow-up in up to 4,850 cases and 451,731 controls...

  19. Isolated mitral valve prolapse: chordal architecture as an anatomic basis in older patients

    NARCIS (Netherlands)

    van der Bel-Kahn, J.; Duren, D. R.; Becker, A. E.

    1985-01-01

    Ten patients with an average age of 58 years underwent valve replacement because of isolated mitral valve prolapse with severe regurgitation. None had clinical evidence of Marfan's syndrome or another systemic disease that would indicate that a primary connective tissue disorder was the cause of the

  20. NHI program for introducing thoracoscopic minimally invasive mitral and tricuspid valve surgery

    Directory of Open Access Journals (Sweden)

    Tamer El Banna

    2014-03-01

    Conclusions: Thoracoscopic minimally invasive mitral valve surgery can be performed safely but definitely requires a learning curve. Good results and a high patient satisfaction are guaranteed. We now utilize this approach for isolated atrioventricular valve disease and our plan is to make this exclusive by the end of this year for all the patients except Redo Cases.

  1. Investigations into the myocardial metabolism of 123-I-ω-HDA in patients showing the clinical signs and symptoms of mitral valve prolapse and previously proven to have no coronary heart disease

    International Nuclear Information System (INIS)

    Voth, E.

    1987-01-01

    In 53 patients showing the clinical signs and symptoms of mitral valve prolapse (MVP) where coronary heart disease (CHD) had previously been excluded by angiography the myocardial metabolism of fatty acids was examined at rest using metabolic myocardial scintigraphy (MMS) and 123-I-ω-HDA as tracer substance. The results were correlated with those obtained by other methods of investigation (findings at rest and during exercise from ECG recordings, tests using a flow-guided catheter and radionuclide ventriculography, further from echocardiography as well as myocardial Tl redistribution scintiscanning during exercise). For purposes of reference, MMS was additionally carried out in twelve normal individuals subjected to coronary angiography to exclude both MVP and CHD. The results of this study would appear to suggest that the pathological findings revealed by myocardial Tl scintigraphy in patients showing symptoms of MVP cannot invariably be classified as 'false' but are at least to some extent attributable to impaired myocardial perfusion, vitality or metabolism. (orig./MG) [de

  2. Prescribing of Electronic Activity Monitors in Cardiometabolic Diseases: Qualitative Interview-Based Study.

    Science.gov (United States)

    Bellicha, Alice; Macé, Sandrine; Oppert, Jean-Michel

    2017-09-23

    The prevalence of noncommunicable diseases, including those such as type 2 diabetes, obesity, dyslipidemia, and hypertension, so-called cardiometabolic diseases, is high and is increasing worldwide. Strong evidence supports the role of physical activity in management of these diseases. There is general consensus that mHealth technology, including electronic activity monitors, can potentially increase physical activity in patients, but their use in clinical settings remains limited. Practitioners' requirements when prescribing electronic activity monitors have been poorly described. The aims of this qualitative study were (1) to explore how specialist physicians prescribe electronic activity monitors to patients presenting with cardiometabolic conditions, and (2) to better understand their motivation for and barriers to prescribing such monitors. We conducted qualitative semistructured interviews in March to May 2016 with 11 senior physicians from a public university hospital in France with expertise in management of cardiometabolic diseases (type 1 and type 2 diabetes, obesity, hypertension, and dyslipidemia). Interviews lasted 45 to 60 minutes and were audiotaped, transcribed verbatim, and analyzed using directed content analysis. We report our findings following the Consolidated Criteria for Reporting Qualitative Research (COREQ) checklist. Most physicians we interviewed had never prescribed electronic activity monitors, whereas they frequently prescribed blood glucose or blood pressure self-monitoring devices. Reasons for nonprescription included lack of interest in the data collected, lack of evidence for data accuracy, concern about work overload possibly resulting from automatic data transfer, and risk of patients becoming addicted to data. Physicians expected future marketing of easy-to-use monitors that will accurately measure physical activity duration and intensity and provide understandable motivating feedback. Features of electronic activity monitors

  3. Role of Mitochondrial Reverse Electron Transport in ROS Signaling: Potential Roles in Health and Disease

    Directory of Open Access Journals (Sweden)

    Filippo Scialò

    2017-06-01

    Full Text Available Reactive Oxygen Species (ROS can cause oxidative damage and have been proposed to be the main cause of aging and age-related diseases including cancer, diabetes and Parkinson's disease. Accordingly, mitochondria from old individuals have higher levels of ROS. However, ROS also participate in cellular signaling, are instrumental for several physiological processes and boosting ROS levels in model organisms extends lifespan. The current consensus is that low levels of ROS are beneficial, facilitating adaptation to stress via signaling, whereas high levels of ROS are deleterious because they trigger oxidative stress. Based on this model the amount of ROS should determine the physiological effect. However, recent data suggests that the site at which ROS are generated is also instrumental in determining effects on cellular homeostasis. The best example of site-specific ROS signaling is reverse electron transport (RET. RET is produced when electrons from ubiquinol are transferred back to respiratory complex I, reducing NAD+ to NADH. This process generates a significant amount of ROS. RET has been shown to be instrumental for the activation of macrophages in response to bacterial infection, re-organization of the electron transport chain in response to changes in energy supply and adaptation of the carotid body to changes in oxygen levels. In Drosophila melanogaster, stimulating RET extends lifespan. Here, we review what is known about RET, as an example of site-specific ROS signaling, and its implications for the field of redox biology.

  4. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  5. Native T1 Relaxation Time and Extracellular Volume Fraction as Accurate Markers of Diffuse Myocardial Fibrosis in Heart Valve Disease - Comparison With Targeted Left Ventricular Myocardial Biopsy -

    Czech Academy of Sciences Publication Activity Database

    Kočková, Radka; Kačer, P.; Pirk, J.; Malý, J.; Sukupová, L.; Sikula, V.; Kotrc, M.; Barciaková, L.; Honsová, E.; Malý, M.; Kautzner, J.; Sedmera, David; Penicka, M.

    2016-01-01

    Roč. 80, č. 5 (2016), s. 1202-1209 ISSN 1346-9843 R&D Projects: GA ČR(CZ) GAP302/11/1308 Institutional support: RVO:67985823 Keywords : cardiac magnetic resonance imaging * echocardiography * fibrosis * speckle tracking * valvular disease Subject RIV: EA - Cell Biology Impact factor: 3.544, year: 2016

  6. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  7. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  8. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  9. Lipoprotein(a Induces Human Aortic Valve Interstitial Cell Calcification

    Directory of Open Access Journals (Sweden)

    Bin Yu, PhD

    2017-08-01

    Full Text Available Lipoprotein(a, or Lp(a, significantly increased alkaline phosphatase activity, release of phosphate, calcium deposition, hydroxyapatite, cell apoptosis, matrix vesicle formation, and phosphorylation of signal transduction proteins; increased expression of chondro-osteogenic mediators; and decreased SOX9 and matrix Gla protein (p < 0.001. Inhibition of MAPK38 and GSK3β significantly reduced Lp(a-induced calcification of human aortic valve interstitial cells (p < 0.001. There was abundant presence of Lp(a and E06 immunoreactivity in diseased human aortic valves. The present study demonstrates a causal effect for Lp(a in aortic valve calcification and suggests that interfering with the Lp(apathway could provide a novel therapeutic approach in the management of this debilitating disease.

  10. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  11. Elemental analysis of occupational and environmental lung diseases by electron probe microanalyzer with wavelength dispersive spectrometer.

    Science.gov (United States)

    Takada, Toshinori; Moriyama, Hiroshi; Suzuki, Eiichi

    2014-01-01

    Occupational and environmental lung diseases are a group of pulmonary disorders caused by inhalation of harmful particles, mists, vapors or gases. Mineralogical analysis is not generally required in the diagnosis of most cases of these diseases. Apart from minerals that are encountered rarely or only in specific occupations, small quantities of mineral dusts are present in the healthy lung. As such when mineralogical analysis is required, quantitative or semi-quantitative methods must be employed. An electron probe microanalyzer with wavelength dispersive spectrometer (EPMA-WDS) enables analysis of human lung tissue for deposits of elements by both qualitative and semi-quantitative methods. Since 1993, we have analyzed 162 cases of suspected occupational and environmental lung diseases using an EPMA-WDS. Our institute has been accepting online requests for elemental analysis of lung tissue samples by EPMA-WDS since January 2011. Hard metal lung disease is an occupational interstitial lung disease that primarily affects workers exposed to the dust of tungsten carbide. The characteristic pathological findings of the disease are giant cell interstitial pneumonia (GIP) with centrilobular fibrosis, surrounded by mild alveolitis with giant cells within the alveolar space. EPMA-WDS analysis of biopsied lung tissue from patients with GIP has demonstrated that tungsten and/or cobalt is distributed in the giant cells and centrilobular fibrosing lesion in GIP. Pneumoconiosis, caused by amorphous silica, and acute interstitial pneumonia, associated with the giant tsunami, were also elementally analyzed by EPMA-WDS. The results suggest that commonly found elements, such as silicon, aluminum, and iron, may cause occupational and environmental lung diseases. Copyright © 2013 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.

  12. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  13. Project and construction of energy degrading and scattering plates for electron beam radiotherapy for skin diseases

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva

    2010-01-01

    There are many radiosensitive epidermotropics diseases such as mycosis fungo-ids and the syndrome of Sezary, coetaneous neoplasics originated from type T lymphocytes. Several studies indicate the eradication of the disease when treated with linear accelerators emitting electron beams with energies between 4 to 10 MeV. However, this treatment technique presents innumerable technical challenges since the disease in general reaches all patient's body, becoming necessary not only a very large field size radiation beam, but also deliver superficial doses limited to the skin depth. To reach the uniformity in the dose distribution, many techniques had already been developed. Based on these previous studies and guided by the report no. 23 of the American Association of Physicists in Medi-cine (AAPM), the present study developed an energy scattering and degrading plates and made dosimetry (computational and experimental), supplying subsidies for a future installation of Total Skin Electron Therapy (TSET) at the Servico de Radioterapia do Hospital das Clinicas de Sao Paulo. As part of the plates design, first of all, the energy spectrum of the 6 MeV electron beam of the VARIAN 2100C accelerator was reconstructed through Monte Carlo simulations using the MCNP4C code and based on experimental data. Once the spectrum is built, several materials were analyzed for the plates design based on radial and axial dose distribution, production of rays-x and dose attenuation. The simulation results were validated by experimental measurements in order to obtain a large field of radiation with 200 cm x 80 cm that meets the specifications of the AAPM protocol. (author)

  14. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  15. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  16. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Triple valve infective endocarditis - a late diagnosis

    Directory of Open Access Journals (Sweden)

    Edme R. Mustafa

    2018-04-01

    Full Text Available Behcet's disease is a systemic vasculitis of unknown aetiology with cardiac involvement as well as damage to other organs. Whether the sterile valvular inflammation which occurs in this autoimmune disease predisposes to bacterial adhesion and infective endocarditis is not yet established. We present the case of a patient with Behcet disease in which transthoracic echocardiography showed mobile masses on the aortic, tricuspid, and mitral valves, leading to multivalvular infective endocarditis diagnosis, possibly in the context of valvular inflammation. The case presented in this article confirms observation of other studies, namely that ultrasonography plays an important role in the diagnosis and evaluation of rheumatic diseases and permits optimal management in daily practice.

  18. A 29-year-old Harken disk mitral valve: long-term follow-up by echocardiographic and cineradiographic imaging.

    Science.gov (United States)

    Hsi, David H; Ryan, Gerald F; Taft, Janice; Arnone, Thomas J

    2003-01-01

    An 81-year-old woman was evaluated for prosthetic mitral valve function. She had received a Harken disk mitral valve 29 years earlier due to severe mitral valve disease. This particular valve prosthesis is known for premature disk edge wear and erosion. The patients 2-dimensional Doppler echocardiogram showed the distinctive appearance of a disk mitral valve prosthesis. Color Doppler in diastole showed a unique crown appearance, with initial flow acceleration around the disk followed by convergence to laminar flow in the left ventricle. Cineradiographic imaging revealed normal valve function and minimal disk erosion. We believe this to be the longest reported follow-up of a surviving patient with a rare Harken disk valve. We present images with unique echocardiographic and cineangiographic features.

  19. High-Compression-Ratio; Atkinson-Cycle Engine Using Low-Pressure Direct Injection and Pneumatic-Electronic Valve Actuation Enabled by Ionization Current and Foward-Backward Mass Air Flow Sensor Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Harold Schock; Farhad Jaberi; Ahmed Naguib; Guoming Zhu; David Hung

    2007-12-31

    This report describes the work completed over a two and one half year effort sponsored by the US Department of Energy. The goal was to demonstrate the technology needed to produce a highly efficient engine enabled by several technologies which were to be developed in the course of the work. The technologies included: (1) A low-pressure direct injection system; (2) A mass air flow sensor which would measure the net airflow into the engine on a per cycle basis; (3) A feedback control system enabled by measuring ionization current signals from the spark plug gap; and (4) An infinitely variable cam actuation system based on a pneumatic-hydraulic valve actuation These developments were supplemented by the use of advanced large eddy simulations as well as evaluations of fuel air mixing using the KIVA and WAVE models. The simulations were accompanied by experimental verification when possible. In this effort a solid base has been established for continued development of the advanced engine concepts originally proposed. Due to problems with the valve actuation system a complete demonstration of the engine concept originally proposed was not possible. Some of the highlights that were accomplished during this effort are: (1) A forward-backward mass air flow sensor has been developed and a patent application for the device has been submitted. We are optimistic that this technology will have a particular application in variable valve timing direct injection systems for IC engines. (2) The biggest effort on this project has involved the development of the pneumatic-hydraulic valve actuation system. This system was originally purchased from Cargine, a Swedish supplier and is in the development stage. To date we have not been able to use the actuators to control the exhaust valves, although the actuators have been successfully employed to control the intake valves. The reason for this is the additional complication associated with variable back pressure on the exhaust valves when

  20. ISS--an electronic syndromic surveillance system for infectious disease in rural China.

    Directory of Open Access Journals (Sweden)

    Weirong Yan

    Full Text Available BACKGROUND: Syndromic surveillance system has great advantages in promoting the early detection of epidemics and reducing the necessities of disease confirmation, and it is especially effective for surveillance in resource poor settings. However, most current syndromic surveillance systems are established in developed countries, and there are very few reports on the development of an electronic syndromic surveillance system in resource-constrained settings. OBJECTIVE: This study describes the design and pilot implementation of an electronic surveillance system (ISS for the early detection of infectious disease epidemics in rural China, complementing the conventional case report surveillance system. METHODS: ISS was developed based on an existing platform 'Crisis Information Sharing Platform' (CRISP, combining with modern communication and GIS technology. ISS has four interconnected functions: 1 work group and communication group; 2 data source and collection; 3 data visualization; and 4 outbreak detection and alerting. RESULTS: As of Jan. 31(st 2012, ISS has been installed and pilot tested for six months in four counties in rural China. 95 health facilities, 14 pharmacies and 24 primary schools participated in the pilot study, entering respectively 74,256, 79,701, and 2330 daily records into the central database. More than 90% of surveillance units at the study sites are able to send daily information into the system. In the paper, we also presented the pilot data from health facilities in the two counties, which showed the ISS system had the potential to identify the change of disease patterns at the community level. CONCLUSIONS: The ISS platform may facilitate the early detection of infectious disease epidemic as it provides near real-time syndromic data collection, interactive visualization, and automated aberration detection. However, several constraints and challenges were encountered during the pilot implementation of ISS in rural China.

  1. Bicuspid aortic valve

    Science.gov (United States)

    ... aortic disease. In: Otto CM, Bonow RO, eds. Valvular Heart Disease: A Companion to Braunwald’s Heart Disease . 4th ed. ... PA: Elsevier Saunders; 2014:chap 13. Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman’s Cecil ...

  2. Coronary artery disease risk assessment from unstructured electronic health records using text mining.

    Science.gov (United States)

    Jonnagaddala, Jitendra; Liaw, Siaw-Teng; Ray, Pradeep; Kumar, Manish; Chang, Nai-Wen; Dai, Hong-Jie

    2015-12-01

    Coronary artery disease (CAD) often leads to myocardial infarction, which may be fatal. Risk factors can be used to predict CAD, which may subsequently lead to prevention or early intervention. Patient data such as co-morbidities, medication history, social history and family history are required to determine the risk factors for a disease. However, risk factor data are usually embedded in unstructured clinical narratives if the data is not collected specifically for risk assessment purposes. Clinical text mining can be used to extract data related to risk factors from unstructured clinical notes. This study presents methods to extract Framingham risk factors from unstructured electronic health records using clinical text mining and to calculate 10-year coronary artery disease risk scores in a cohort of diabetic patients. We developed a rule-based system to extract risk factors: age, gender, total cholesterol, HDL-C, blood pressure, diabetes history and smoking history. The results showed that the output from the text mining system was reliable, but there was a significant amount of missing data to calculate the Framingham risk score. A systematic approach for understanding missing data was followed by implementation of imputation strategies. An analysis of the 10-year Framingham risk scores for coronary artery disease in this cohort has shown that the majority of the diabetic patients are at moderate risk of CAD. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Early and late scanning electron microscopy findings in diabetic kidney disease.

    Science.gov (United States)

    Conti, Sara; Perico, Norberto; Novelli, Rubina; Carrara, Camillo; Benigni, Ariela; Remuzzi, Giuseppe

    2018-03-20

    Diabetic nephropathy (DN), the single strongest predictor of mortality in patients with type 2 diabetes, is characterized by initial glomerular hyperfiltration with subsequent progressive renal function loss with or without albuminuria, greatly accelerated with the onset of overt proteinuria. Experimental and clinical studies have convincingly shown that early interventions retard disease progression, while treatment if started late in the disease course seldom modifies the slope of GFR decline. Here we assessed whether the negligible renoprotection afforded by drugs in patients with proteinuric DN could be due to loss of glomerular structural integrity, explored by scanning electron microscopy (SEM). In diabetic patients with early renal disease, glomerular structural integrity was largely preserved. At variance SEM documented that in the late stage of proteinuric DN, glomerular structure was subverted with nearly complete loss of podocytes and lobular transformation of the glomerular basement membrane. In these circumstances one can reasonably imply that any form of treatment, albeit personalized, is unlikely to reach a given cellular or molecular target. These findings should persuade physicians to start the putative renoprotective therapy soon after the diagnosis of diabetes or in an early phase of the disease before structural integrity of the glomerular filter is irreversibly compromised.

  4. Markers of Oxidative Stress in Dogs with Myxomatous Mitral Valve Disease are Influenced by Sex, Neuter Status, and Serum Cholesterol Concentration

    DEFF Research Database (Denmark)

    Reimann, M J; Häggström, J; Møller, J E

    2017-01-01

    -tocopherol [P = .003]) was associated with body condition score (BCS), but the association disappeared when cholesterol was included in the analyses. All markers of oxidative stress (MDA, oxLDL, and vitamin E) were positively associated with serum cholesterol concentration (P ≤ .04), but none were associated...... with clinical stage of MMVD. CONCLUSIONS: In conclusion, markers of oxidative stress are associated with sex, BCS, neuter status, and cholesterol. The results cannot confirm a relationship between oxidative stress and clinical stage of the disease in dogs with MMVD....

  5. Options for Heart Valve Replacement

    Science.gov (United States)

    ... Guide: Understanding Your Heart Valve Problem | Spanish Symptom Tracker | Spanish Pre-surgery Checklist | Spanish What Is Heart ... Cardiac Arrest: How Are They Different? 7 Warning Signs of a Heart Attack 8 Low Blood Pressure - ...

  6. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  7. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  8. Transcatheter Pulmonary Valve Replacement: Current State of Art.

    Science.gov (United States)

    Alkashkari, Wail; Alsubei, Amani; Hijazi, Ziyad M

    2018-03-15

    The past couple of decades have brought tremendous advances to the field of pediatric and adult congenital heart disease (CHD). Percutaneous valve interventions are now a cornerstone of not just the congenital cardiologist treating patients with congenital heart disease, but also-and numerically more importantly-for adult interventional cardiologists treating patients with acquired heart valve disease. Transcatheter pulmonary valve replacement (tPVR) is one of the most exciting recent developments in the treatment of CHD and has evolved to become an attractive alternative to surgery in patients with right ventricular outflow tract (RVOT) dysfunction. This review aims to summarize (1) the current state of the art for tPVR, (2) the expanding indications, and (3) the technological obstacles to optimizing tPVR. Since its introduction in 2000, more than ten thousands tPVR procedures have been performed worldwide. Although the indications for tPVR have been adapted earlier from those accepted for surgical intervention, they remain incompletely defined. The new imaging modalities give better assessment of cardiac anatomy and function and determine candidacy for the procedure. The procedure has been shown to be feasible and safe when performed in patients who received pulmonary conduit and or bioprosthetic valves between the right ventricle and the pulmonary artery. Fewer selected patients post trans-annular patch repair for tetralogy of Fallot may also be candidates for this technology. Size restrictions of the currently available valves limit deployment in the majority of patients post trans-annular patch repair. Newer valves and techniques are being developed that may help such patients. Refinements and further developments of this procedure hold promise for the extension of this technology to other patient populations.

  9. Tissue properties and collagen remodeling in heart valve tissue engineering

    NARCIS (Netherlands)

    Geemen, van D.

    2012-01-01

    Valvular heart disease is a major health problem worldwide causing morbidity and mortality. Heart valve replacement is frequently applied to avoid serious cardiac, pulmonary, or systemic problems. However, the current replacements do not consist of living tissue and, consequently, cannot grow,

  10. Perivalvular pannus and valve thrombosis: two concurrent mechanisms of mechanical valve prosthesis dysfunction.

    Science.gov (United States)

    Arnáiz-García, María Elena; González-Santos, Jose María; Bueno-Codoñer, María E; López-Rodríguez, Javier; Dalmau-Sorlí, María José; Arévalo-Abascal, Adolfo; Arribas-Jiménez, Antonio; Diego-Nieto, Alejandro; Rodríguez-Collado, Javier; Rodríguez-López, Jose María

    2015-02-01

    A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  11. Associations of rs3918242 and rs2285053 MMP-9 and MMP-2 polymorphisms with the risk, severity, and short- and long-term complications of degenerative mitral valve diseases: a 4.8-year prospective cohort study.

    Science.gov (United States)

    Balistreri, Carmela Rita; Allegra, Alberto; Crapanzano, Floriana; Pisano, Calogera; Triolo, Oreste Fabio; Argano, Vincenzo; Candore, Giuseppina; Lio, Domenico; Ruvolo, Giovanni

    2016-01-01

    Degenerative forms of mitral valve diseases (MVDs) are very complex pathologies. Thus, it is difficult to make generalizations about the disease pathways or genetic risk factors contributing to these diseases. However, a key role of metalloproteinases (MMPs) in their pathophysiology is emerging. Thus, we performed for the first time a perspective study to assess eventual associations of some functional single nucleotide polymorphisms (SNPs) in MMP-2 and MMP-9 genes with the MVD risk, symptom severity, and short- and long-term (4.8 years) complications. For this purpose, 90 patients and two control groups were genotyped for rs3918242, rs243865, and rs2285053 MMP-2 and MMP-9 gene SNPs, and systemic levels of pro-atrial natriuretic peptide (pro-ANP) and two enzymes were quantified and correlated to genotypes of MMP-2 and MMP-9 SNPs studied. In addition, associations between these SNPs and symptom severity and short- and long-term (4.8 years) complications were evaluated. Interestingly, rs3918242 MMP-9 and rs2285053 MMP-2 SNPs were significantly represented in cases than two control groups and were associated with a higher MVD risk, as demonstrated using dominant/recessive models. Cases stratified for NYHA symptoms and particularly those NYHA III+IV with rs3918242 CT+TT MMP-9 and rs2285053CT+TT genotypes also showed higher severity related to significant higher systemic levels of MMP enzymes and pro-ANP at enrolment and 4.8 follow-up times. In addition, cases with these genotypes and particularly those NYHA III+IV had a very significant percentage of complications, particularly at the 4.8 follow-up. Surprisingly, 20% of patient controls developed MVD at 4.8-year follow-up and were carriers of these genotypes. Thus, the associations observed seem to suggest that the two SNPs might represent useful biomarkers and targets for preventing and monitoring MVDs and developing personalized treatments, consenting a more appropriate management and outcome. Copyright © 2016

  12. Electronics

    Science.gov (United States)

    2001-01-01

    International Acer Incorporated, Hsin Chu, Taiwan Aerospace Industrial Development Corporation, Taichung, Taiwan American Institute of Taiwan, Taipei, Taiwan...Singapore and Malaysia .5 - 4 - The largest market for semiconductor products is the high technology consumer electronics industry that consumes up...Singapore, and Malaysia . A new semiconductor facility costs around $3 billion to build and takes about two years to become operational

  13. Electron/photon matched field technique for treatment of orbital disease

    International Nuclear Information System (INIS)

    Arthur, Douglas W.; Zwicker, Robert D.; Garmon, Pamela W.; Huang, David T.; Schmidt-Ullrich, Rupert K.

    1997-01-01

    Purpose: A number of approaches have been described in the literature for irradiation of malignant and benign diseases of the orbit. Techniques described to date do not deliver a homogeneous dose to the orbital contents while sparing the cornea and lens of excessive dose. This is a result of the geometry encountered in this region and the fact that the target volume, which includes the periorbital and retroorbital tissues but excludes the cornea, anterior chamber, and lens, cannot be readily accommodated by photon beams alone. To improve the dose distribution for these treatments, we have developed a technique that combines a low-energy electron field carefully matched with modified photon fields to achieve acceptable dose coverage and uniformity. Methods and Materials: An anterior electron field and a lateral photon field setup is used to encompass the target volume. Modification of these fields permits accurate matching as well as conformation of the dose distribution to the orbit. A flat-surfaced wax compensator assures uniform electron penetration across the field, and a sunken lead alloy eye block prevents excessive dose to the central structures of the anterior segment. The anterior edge of the photon field is modified by broadening the penumbra using a form of pseudodynamic collimation. Direct measurements using film and ion chamber dosimetry were used to study the characteristics of the fall-off region of the electron field and the penumbra of the photon fields. >From the data collected, the technique for accurate field matching and dose uniformity was generated. Results: The isodose curves produced with this treatment technique demonstrate homogeneous dose coverage of the orbit, including the paralenticular region, and sufficient dose sparing of the anterior segment. The posterior lens accumulates less than 40% of the prescribed dose, and the lateral aspect of the lens receives less than 30%. A dose variation in the match region of ±12% is confronted when

  14. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  15. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  16. Prosthetic Valve Endocarditis - Successful Management With Antimicrobial Treatment

    Directory of Open Access Journals (Sweden)

    Ashokan Nambiar C

    2015-07-01

    Full Text Available Middle aged male was admitted with high fever, rigor and chills of 2 days duration. He was seen in the clinic two years back for syncope. He gave history of Mitral (Starr-Edward and Aortic (Medtronic valve replacement ten years earlier from another center and was on regular anticoagulation with dose-adjusted acenocoumarol. On evaluation he had normal prosthetic valve function by trans-thoracic echo, but Holter monitoring showed Paroxysmal Atrial Fibrillation. He had mild wall motion abnormalities and left ventricular dysfunction suggestive of coronary artery disease also and was put on additional Metoprolol.

  17. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  18. The surface microstructure of cusps and leaflets in rabbit and mouse heart valves

    Directory of Open Access Journals (Sweden)

    Xia Ye

    2014-05-01

    Full Text Available In this investigation, scanning electron microscopy was used to characterize the microstructure on the surfaces of animal heart valve cusps/leaflets. The results showed that though these surfaces appear smooth to the naked eye, they are actually comprised of a double hierarchical structure consisting of a cobblestone-like microstructure and nano-cilia along with mastoids with a directional arrangement. Such nanostructures could play a very important role in the hemocompatibility characteristics of heart valves. On this basis, the model of the microstructure was constructed and theoretical analysis was used to obtain optimal geometric parameters for the rough surface of artificial valve cusps/leaflets. This model may help improve reconstructive techniques and it may be beneficial in the design and fabrication of valve substitutes or partial substitutes. Namely, the model may help ameliorate heart valve replacement surgery.

  19. Design Method for Fast Switching Seat Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    corresponding to the piston movement, which has been shown to facilitate superior part load efficiency combined with high bandwidth compared to traditional displacement machines. However, DD machines need fast switching on-off valves with low pressure loss for efficient operation, especially in fast rotating......Digital Displacement (DD) machines are upcoming technology where the displacement of each pressure chamber is controlled electronically by use of two fast switching seat valves. The effective displacement and operation type (pumping/motoring) may be controlled by manipulating the seat valves...... method for DD seat valves are presented, taking into account the significant aspects related to obtaining efficient DD valves with basis in a given DD machine specifications. The seat area is minimized and the stroke length is minimized to obtain fast switching times while considering the pressure loss...

  20. CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shunsuke; Yamada, Yoshitake; Hashimoto, Masahiro; Okamura, Teppei; Jinzaki, Masahiro [Keio University School of Medicine, Department of Diagnostic Radiology, Shinanomachi, Shinjuku-ku, Tokyo (Japan); Yamada, Minoru [Keio University School of Medicine, Research Park, Tokyo (Japan); Yashima, Fumiaki; Hayashida, Kentaro; Fukuda, Keiichi [Keio University School of Medicine, Department of Cardiology, Tokyo (Japan)

    2017-05-15

    To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD). Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time x weight [kg] x 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard. The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV). CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD. (orig.)

  1. Electronic Transport in Single-Stranded DNA Molecule Related to Huntington's Disease

    Science.gov (United States)

    Sarmento, R. G.; Silva, R. N. O.; Madeira, M. P.; Frazão, N. F.; Sousa, J. O.; Macedo-Filho, A.

    2018-04-01

    We report a numerical analysis of the electronic transport in single chain DNA molecule consisting of 182 nucleotides. The DNA chains studied were extracted from a segment of the human chromosome 4p16.3, which were modified by expansion of CAG (cytosine-adenine-guanine) triplet repeats to mimics Huntington's disease. The mutated DNA chains were connected between two platinum electrodes to analyze the relationship between charge propagation in the molecule and Huntington's disease. The computations were performed within a tight-binding model, together with a transfer matrix technique, to investigate the current-voltage (I-V) of 23 types of DNA sequence and compare them with the distributions of the related CAG repeat numbers with the disease. All DNA sequences studied have a characteristic behavior of a semiconductor. In addition, the results showed a direct correlation between the current-voltage curves and the distributions of the CAG repeat numbers, suggesting possible applications in the development of DNA-based biosensors for molecular diagnostics.

  2. Correlation between obstructive coronary artery disease and electron beam tomography coronary artery calcium scan

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Hong, Yong Kook; Park, Sung Il; Lee, Hyang Mee; Choe, Kyu Ok

    1998-01-01

    To determine the correlation between obstructive coronary artery disease and electron beam tomography coronary artery calcium(EBT CAC) scan and to measure the difference in calcium score according to symptoms. Materials and Methods : Fifty-six patients underwent EBT CAC scanning and either coronary angiography or stress thallium 201 scanning or the treadmill test. When the results were positive, coronary artery obstructive disease(CAOD) was assumed to be present. The patients were divided into three groups : symptomatic CAOD,asymptomatic CAOD, and asymptomatic non- CAOD; those with a previous history of myocardial ischemia or who showed positive results in any of the three tests relating to typical symptoms of angina were assigned to the symptomatic group. Results : The number of cases assigned to group to group 1,2 and 3 was 19, 16 and 21, respectively; total CAC scores were 571 ± 751, 600 ± 726 293± 401, respectively. The difference in CAC score between asymptomatic CAOD and asymptomatic non- CAOD was not statistically significant(p=0.079) but in asymptomatic CAOD, the score tended to be higher. The CAC score was not different between symptomatic and asymptomatic CAOD(p>0.1). When the CAC threshold was 1, sensitivity was 89% and specificity was 14%;when the threshold was 200, sensitivity was 60% and specificity was 67%. Conclusion : When the EBT CAC score is high, further evaluation provides early evidence of coronary artery obstructive disease

  3. Soft valves in plants

    Science.gov (United States)

    Park, Keunhwan; Tixier, Aude; Christensen, Anneline; Arnbjerg-Nielsen, Sif; Zwieniecki, Maciej; Jensen, Kaare

    2017-11-01

    Water and minerals flow from plant roots to leaves in the xylem, an interconnected network of vascular conduits that spans the full length of the organism. When a plant is subjected to drought stress, air pockets can spread inside the xylem, threatening the survival of the plant. Many plants prevent propagation of air by using hydrophobic nano-membranes in the ``pit'' pores that link adjacent xylem cells. This adds considerable resistance to flow. Interestingly, torus-margo pit pores in conifers are open and offer less resistance. To prevent propagation of air, conifers use a soft gating mechanism, which relies on hydrodynamic interactions between the xylem liquid and the elastic pit. However, it is unknown exactly how it is able to combine the seemingly antagonist functions of high permeability and resistance to propagation of air. We conduct experiments on biomimetic pores to elucidate the flow regulation mechanism. The design of plant valves is compared to other natural systems and optimal strategies are discussed. This work was supported by a research Grant (13166) from VILLUM FONDEN.

  4. Annular flow diverter valve

    International Nuclear Information System (INIS)

    Rider, R.L.

    1980-01-01

    A valve is described for diverting flow from the center of two concentric tubes to the annulus between the tubes or, operating in the reverse direction, for mixing fluids from concentric tubes into a common tube and for controlling the volume ratio of said flow. It consists of a toroidal baffle disposed in sliding engagement with the interior of the inner tube downstream of a plurality of ports in the inner tube, a plurality of gates in sliding engagement with the interior of the inner tube attached to the baffle for movement therewith, a servomotor having a bullet-shaped plug on the downstream end thereof, and drive rods connecting the servomotor to the toroidal baffle. The sevomotor is adapted to move the baffle into mating engagement with the bullet-shaped plug and simultaneously move the gates away from the ports in the inner tube and to move the baffle away from the bullet-shaped plug and simultaneously move the gates to cover the ports in the inner tube

  5. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  6. Detection of coronary calcium with electron beam tomography in coronary artery disease

    International Nuclear Information System (INIS)

    Haberl, R.; Knez, A.; Becker, A.; Becker, C.; Bruening, R.; Reiser, M.; Maass, A.; Steinbeck, G.

    1998-01-01

    Purpose: Coronary calcium is a powerful indicator of arteriosclerosis and can be detected very precisely with electron beam tomography. The method can be applied in patients with known coronary artery disease or in asymptomatic patients at risk of arteriosclerotic disease. Results: At the University of Munich we performed an EBT scan of the heart in 1100 patients within the last year. In 567 patients coronary angiography was performed also (±3 days). Confirming previous reports in the literature, we found a correlation of the calcium score with the age and gender of the patients. Severe coronary artery disease (stenoses ≥ 75%) was associated with significantly more calcium than less severe CAD. The calcium score did not discriminate between one-, two- and three-vessel disease. The site of calcification does not correlate with the localization of stenoses. Thirty-three percent of the patients with significant coronary artery disease showed a normal age-adjusted calcium score; a total of 8.1% of patients with severe stenoses did not reveal any coronary calcification (score =0). With asymptomatic patients there are only a few studies available. Soft plaques cannot be detected with EBT, but in most patients soft plaques occur together with hard plaques. Our results show that spiral CT of the newest generation may also be used for calcium screening. There was an excellent correlation of the calcium scores of EBT and spiral CT at all levels of calcification. Discussion: Coronary calcium is a sensitive marker of coronary artery disease. In the clinical setting EBT is indicated in patients with known coronary artery disease (to evaluate prognosis), in patients who are unable to perform a stress test, and in patients with atypical chest pain. However, lack of calcification may be associated with severe stenoses in a minority of patients. The clinical value in asymptomatic patients needs to be defined: Randomized studies are necessary. We see a possible indication in

  7. Large-scale community echocardiographic screening reveals a major burden of undiagnosed valvular heart disease in older people: the OxVALVE Population Cohort Study†

    Science.gov (United States)

    d'Arcy, Joanna L.; Coffey, Sean; Loudon, Margaret A.; Kennedy, Andrew; Pearson-Stuttard, Jonathan; Birks, Jacqueline; Frangou, Eleni; Farmer, Andrew J.; Mant, David; Wilson, Jo; Myerson, Saul G.; Prendergast, Bernard D.

    2016-01-01

    Background Valvular heart disease (VHD) is expected to become more common as the population ages. However, current estimates of its natural history and prevalence are based on historical studies with potential sources of bias. We conducted a cross-sectional analysis of the clinical and epidemiological characteristics of VHD identified at recruitment of a large cohort of older people. Methods and results We enrolled 2500 individuals aged ≥65 years from a primary care population and screened for undiagnosed VHD using transthoracic echocardiography. Newly identified (predominantly mild) VHD was detected in 51% of participants. The most common abnormalities were aortic sclerosis (34%), mitral regurgitation (22%), and aortic regurgitation (15%). Aortic stenosis was present in 1.3%. The likelihood of undiagnosed VHD was two-fold higher in the two most deprived socioeconomic quintiles than in the most affluent quintile, and three-fold higher in individuals with atrial fibrillation. Clinically significant (moderate or severe) undiagnosed VHD was identified in 6.4%. In addition, 4.9% of the cohort had pre-existing VHD (a total prevalence of 11.3%). Projecting these findings using population data, we estimate that the prevalence of clinically significant VHD will double before 2050. Conclusions Previously undetected VHD affects 1 in 2 of the elderly population and is more common in lower socioeconomic classes. These unique data demonstrate the contemporary clinical and epidemiological characteristics of VHD in a large population-based cohort of older people and confirm the scale of the emerging epidemic of VHD, with widespread implications for clinicians and healthcare resources. PMID:27354049

  8. Large-scale community echocardiographic screening reveals a major burden of undiagnosed valvular heart disease in older people: the OxVALVE Population Cohort Study.

    Science.gov (United States)

    d'Arcy, Joanna L; Coffey, Sean; Loudon, Margaret A; Kennedy, Andrew; Pearson-Stuttard, Jonathan; Birks, Jacqueline; Frangou, Eleni; Farmer, Andrew J; Mant, David; Wilson, Jo; Myerson, Saul G; Prendergast, Bernard D

    2016-12-14

    Valvular heart disease (VHD) is expected to become more common as the population ages. However, current estimates of its natural history and prevalence are based on historical studies with potential sources of bias. We conducted a cross-sectional analysis of the clinical and epidemiological characteristics of VHD identified at recruitment of a large cohort of older people. We enrolled 2500 individuals aged ≥65 years from a primary care population and screened for undiagnosed VHD using transthoracic echocardiography. Newly identified (predominantly mild) VHD was detected in 51% of participants. The most common abnormalities were aortic sclerosis (34%), mitral regurgitation (22%), and aortic regurgitation (15%). Aortic stenosis was present in 1.3%. The likelihood of undiagnosed VHD was two-fold higher in the two most deprived socioeconomic quintiles than in the most affluent quintile, and three-fold higher in individuals with atrial fibrillation. Clinically significant (moderate or severe) undiagnosed VHD was identified in 6.4%. In addition, 4.9% of the cohort had pre-existing VHD (a total prevalence of 11.3%). Projecting these findings using population data, we estimate that the prevalence of clinically significant VHD will double before 2050. Previously undetected VHD affects 1 in 2 of the elderly population and is more common in lower socioeconomic classes. These unique data demonstrate the contemporary clinical and epidemiological characteristics of VHD in a large population-based cohort of older people and confirm the scale of the emerging epidemic of VHD, with widespread implications for clinicians and healthcare resources. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  9. Emergency heart valve replacement: an analysis of 170 patients.

    Science.gov (United States)

    Louw, J W; Kinsley, R H; Dion, R A; Colsen, P R; Girdwood, R W

    1980-05-01

    The results of 170 emergency heart valve procedures performed during a 4 1/2-year period were analyzed. Five pathological groups of patients were recognized: those with infective endocarditis (Group 1, 28 patients); acute rheumatic carditis (Group 2, 43 patients); previous valve operation (Group 3, 29 patients); acute-on-chronic cardiac disease (Group 4, 67 patients); and miscellaneous conditions (Group 5, 3 patients). Mitral, aortic, and multiple valve procedures were performed on 58, 65, and 44 patients, respectively. The most common functional lesion was regurgitation. Hospital mortality was highest in Groups 3 (34%) and 4 (31%). By contrast, among the hospital survivors, the highest rate of attrition was in Group 2. Myocardial failure was the predominat cause of death. In view of the hopeless prognosis without operation, the 52% overall 3-year actuarial survival is a gratifying salvage. Unnecessary procrastination can only jeopardize the prospects for surgical cure.

  10. Anesthetic Management and Complications of Percutaneous Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Tailur Alberto Grando

    2013-05-01

    Full Text Available Background and objective: Aortic stenosis is a highly prevalent and life-threatening disease. In elderly patients with comorbidities, percutaneous valve implantation is an option. The aim of the study was to describe the anesthetic management and complications of general anesthesia Method: Case series with 30-day and 24-month follow-ups after implantation of the CoreValve device performed at the Institute of Cardiology/University Foundation of Cardiology between December 2008 and January 2012. The patients underwent general anesthesia monitored with mean arterial pressure (PAM, electrocardiogram (ECG, pulse oximetry, capnography, transesophageal echocardiography, thermometry, and transvenous pacemaker. Results: Twenty-eight patients, mean age 82.46 years, 20.98% mean EuroSCORE, functional class III/IV, successfully underwent valve implantation. Nine patients required permanent pacemaker implantation. During follow-up, two patients died: one during surgery due to LV perforation and the other on the third day of unknown causes. At 24 months, one patient diagnosed with multiple myeloma died. This anesthetic technique proved to be safe. Conclusion: The initial experience with percutaneous aortic valve implantation under general anesthesia has proven to be safe and effective, with no significant anesthetic complications during this procedure. Keywords: Aesthesia, General, Cardiac Surgical Procedures, Aortic Valve Stenosis, Aged.

  11. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    Science.gov (United States)

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  12. Reasons for conversion and adverse intraoperative events in Endoscopic Port Access™ atrioventricular valve surgery and minimally invasive aortic valve surgery.

    Science.gov (United States)

    van der Merwe, Johan; Van Praet, Frank; Stockman, Bernard; Degrieck, Ivan; Vermeulen, Yvette; Casselman, Filip

    2018-02-14

    This study reports the factors that contribute to sternotomy conversions (SCs) and adverse intraoperative events in minimally invasive aortic valve surgery (MI-AVS) and minimally invasive Endoscopic Port Access™ atrioventricular valve surgery (MI-PAS). In total, 3780 consecutive patients with either aortic valve disease or atrioventricular valve disease underwent minimally invasive valve surgery (MIVS) at our institution between 1 February 1997 and 31 March 2016. MI-AVS was performed in 908 patients (mean age 69.2 ± 11.3 years, 45.2% women, 6.2% redo cardiac surgery) and MI-PAS in 2872 patients (mean age 64.1 ± 13.3 years, 46.7% women, 12.2% redo cardiac surgery). A cumulative total of 4415 MIVS procedures (MI-AVS = 908, MI-PAS = 3507) included 1537 valve replacements (MI-AVS = 896, MI-PAS = 641) and 2878 isolated or combined valve repairs (MI-AVS = 12, MI-PAS = 2866). SC was required in 3.0% (n = 114 of 3780) of MIVS patients, which occurred in 3.1% (n = 28 of 908) of MI-AVS patients and 3.0% (n = 86 of 2872) of MI-PAS patients, respectively. Reasons for SC in MI-AVS included inadequate visualization (n = 4, 0.4%) and arterial cannulation difficulty (n = 7, 0.8%). For MI-PAS, SC was required in 54 (2.5%) isolated mitral valve procedures (n = 2183). Factors that contributed to SC in MI-PAS included lung adhesions (n = 35, 1.2%), inadequate visualization (n = 2, 0.1%), ventricular bleeding (n = 3, 0.1%) and atrioventricular dehiscence (n = 5, 0.2%). Neurological deficit occurred in 1 (0.1%) and 3 (3.5%) MI-AVS and MI-PAS conversions, respectively. No operative or 30-day mortalities were observed in MI-AVS conversions (n = 28). The 30-day mortality associated with SC in MI-PAS (n = 86) was 10.5% (n = 9). MIVS is increasingly being recognized as the 'gold-standard' for surgical valve interventions in the context of rapidly expanding catheter-based technology and increasing

  13. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  14. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  15. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  16. Prognostic value of heart valve calcifications for cardiovascular events in a lung cancer screening population

    OpenAIRE

    Willemink, Martin J.; Takx, Richard A. P.; I?gum, Ivana; de Koning, Harry J.; Oudkerk, Matthijs; Mali, Willem P. Th. M.; Budde, Ricardo P. J.; Leiner, Tim; Vliegenthart, Rozemarijn; de Jong, Pim A.

    2015-01-01

    textabstractTo assess the prognostic value of aortic valve and mitral valve/annulus calcifications for cardiovascular events in heavily smoking men without a history of cardiovascular disease. Heavily smoking men without a cardiovascular disease history who underwent non-contrast-enhanced low-radiation-dose chest CT for lung cancer screening were included. Non-imaging predictors (age, smoking status and pack-years) were collected and imaging-predictors (calcium volume of the coronary arteries...

  17. Community Health Worker Impact on Chronic Disease Outcomes Within Primary Care Examined Using Electronic Health Records.

    Science.gov (United States)

    Ingram, Maia; Doubleday, Kevin; Bell, Melanie L; Lohr, Abby; Murrieta, Lucy; Velasco, Maria; Blackburn, John; Sabo, Samantha; Guernsey de Zapien, Jill; Carvajal, Scott C

    2017-10-01

    To investigate community health worker (CHW) effects on chronic disease outcomes using electronic health records (EHRs). We examined EHRs of 32 147 patients at risk for chronic disease during 2012 to 2015. Variables included contact with clinic-based CHWs, vitals, and laboratory tests. We estimated a mixed model for all outcomes. Within-group findings showed statistically significant improvements in chronic disease indicators after exposure to CHWs. In health center 1, HbA1c (glycated hemoglobin) decreased 0.15 millimoles per mole (95% confidence interval [CI] = -0.24, -0.06), body mass index decreased 0.29 kilograms per meter squared (CI = -0.39, -0.20), and total cholesterol decreased 11.9 milligrams per deciliter (CI = -13.5, -10.2). In health center 2, HbA1c decreased 0.43 millimoles per mole (CI = -0.7, -0.17), body mass index decreased by 0.08 kilograms per meter squared (CI = -0.14, -0.02), and triglycerides decreased by 22.50 milligrams per deciliter (CI = -39.0, -6.0). Total cholesterol of 3.62 milligrams per deciliter (CI = -6.6, -0.6) in health center 1 was the only improvement tied to CHW contact. Although patients' chronic disease indicators consistently improved, between-group models provided no additional evidence of impact. EHRs' evolution may elucidate CHW contributions moving forward.

  18. David valve-sparing aortic root replacement: equivalent mid-term outcome for different valve types with or without connective tissue disorder.

    Science.gov (United States)

    Kvitting, John-Peder Escobar; Kari, Fabian A; Fischbein, Michael P; Liang, David H; Beraud, Anne-Sophie; Stephens, Elizabeth H; Mitchell, R Scott; Miller, D Craig

    2013-01-01

    Although implicitly accepted by many that the durability of valve-sparing aortic root replacement in patients with bicuspid aortic valve disease and connective tissue disorders will be inferior, this hypothesis has not been rigorously investigated. From 1993 to 2009, 233 patients (27% bicuspid aortic valve, 40% Marfan syndrome) underwent Tirone David valve-sparing aortic root replacement. Follow-up averaged 4.7 ± 3.3 years (1102 patient-years). Freedom from adverse outcomes was determined using log-rank calculations. Survival at 5 and 10 years was 98.7% ± 0.7% and 93.5% ± 5.1%, respectively. Freedom from reoperation (all causes) on the aortic root was 92.2% ± 3.6% at 10 years; 3 reoperations were aortic valve replacement owing to structural valve deterioration. Freedom from structural valve deterioration at 10 years was 96.1% ± 2.1%. No significant differences were found in survival (P = .805, P = .793, respectively), reoperation (P = .179, P = .973, respectively), structural valve deterioration (P = .639, P = .982, respectively), or any other functional or clinical endpoints when patients were stratified by valve type (tricuspid aortic valve vs bicuspid aortic valve) or associated connective tissue disorder. At the latest echocardiographic follow-up (95% complete), 202 patients (94.8%) had none or trace aortic regurgitation, 10 (4.7%) mild, 0 had moderate to severe, and 1 (0.5%) had severe aortic regurgitation. Freedom from greater than 2+ aortic regurgitation at 10 years was 95.3% ± 2.5%. Six patients sustained acute type B aortic dissection (freedom at 10 years, 90.4% ± 5.0%). Tirone David reimplantation valve-sparing aortic root replacement in carefully selected young patients was associated with excellent clinical and echocardiographic outcome in patients with either a tricuspid aortic valve or bicuspid aortic valve. No demonstrable adverse influence was found for Marfan syndrome or connective tissue disorder on durability, clinical outcome

  19. Preoperative planning with three-dimensional reconstruction of patient's anatomy, rapid prototyping and simulation for endoscopic mitral valve repair.

    Science.gov (United States)

    Sardari Nia, Peyman; Heuts, Samuel; Daemen, Jean; Luyten, Peter; Vainer, Jindrich; Hoorntje, Jan; Cheriex, Emile; Maessen, Jos

    2017-02-01

    Mitral valve repair performed by an experienced surgeon is superior to mitral valve replacement for degenerative mitral valve disease; however, many surgeons are still deterred from adapting this procedure because of a steep learning curve. Simulation-based training and planning could improve the surgical performance and reduce the learning curve. The aim of this study was to develop a patient-specific simulation for mitral valve repair and provide a proof of concept of personalized medicine in a patient prospectively planned for mitral valve surgery. A 65-year old male with severe symptomatic mitral valve regurgitation was referred to our mitral valve heart team. On the basis of three-dimensional (3D) transoesophageal echocardiography and computed tomography, 3D reconstructions of the patient's anatomy were constructed. By navigating through these reconstructions, the repair options and surgical access were chosen (minimally invasive repair). Using rapid prototyping and negative mould fabrication, we developed a process to cast a patient-specific mitral valve silicone replica for preoperative repair in a high-fidelity simulator. Mitral valve and negative mould were printed in systole to capture the pathology when the valve closes. A patient-specific mitral valve silicone replica was casted and mounted in the simulator. All repair techniques could be performed in the simulator to choose the best repair strategy. As the valve was printed in systole, no special testing other than adjusting the coaptation area was required. Subsequently, the patient was operated, mitral valve pathology was validated and repair was successfully done as in the simulation. The patient-specific simulation and planning could be applied for surgical training, starting the (minimally invasive) mitral valve repair programme, planning of complex cases and the evaluation of new interventional techniques. The personalized medicine could be a possible pathway towards enhancing reproducibility

  20. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    Science.gov (United States)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  1. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  2. Aortic valve replacement in octogenarians

    Directory of Open Access Journals (Sweden)

    Dark John H

    2007-07-01

    Full Text Available Abstract Background and Aims As our population ages and life expectancy increases the number of people aged over 80 and more referred for cardiac surgery is growing. This study sought to identify the outcome of aortic valve replacement (AVR in octogenarians. Methods 68 patients aged 80 years or more underwent AVR at the Freeman Hospital, between April 2001 and April 2004. A retrospective review of the notes and outcomes from the patients' GP and the NHS strategic tracking service was performed. 54% (37 underwent isolated AVR whilst 46% (31 underwent combined AVR and CABG. Results Follow up was 100% complete. The mean age was 83.1 ± s.d. 2.9 years, a mean gradient of 83 ± s.d. 31 mmHg and mean AVA of 0.56 cm2. The mean additive EuroSCORE was 8.6 ± s.d. 1.2, the logistic EuroSCORE mean 12.0 ± s.d. 5.9. In hospital 30 day mortality was 13 %. Survival was 80% at 1 year and 78% at 2 years. Median follow up was for 712 days. Stepwise logistic regression identified chronic obstructive airways disease as an independent predictor of mortality (p Conclusion Our study demonstrates that the operative mortality for AVR in the over eighties is good, whilst the mid to long term outcome is excellent There is a very low attrition rate with those undergoing the procedure living as long than their age matched population. This study confirms AVR is a safe, acceptable treatment for octogenarians with excellent mid term outcomes.

  3. Embryological origin of the endocardium and derived valve progenitor cells: from developmental biology to stem cell-based valve repair.

    Science.gov (United States)

    Pucéat, Michel

    2013-04-01

    The cardiac valves are targets of both congenital and acquired diseases. The formation of valves during embryogenesis (i.e., valvulogenesis) originates from endocardial cells lining the myocardium. These cells undergo an endothelial-mesenchymal transition, proliferate and migrate within an extracellular matrix. This leads to the formation of bilateral cardiac cushions in both the atrioventricular canal and the outflow tract. The embryonic origin of both the endocardium and prospective valve cells is still elusive. Endocardial and myocardial lineages are segregated early during embryogenesis and such a cell fate decision can be recapitulated in vitro by embryonic stem cells (ESC). Besides genetically modified mice and ex vivo heart explants, ESCs provide a cellular model to study the early steps of valve development and might constitute a human therapeutic cell source for decellularized tissue-engineered valves. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Cardiac Pathways of Differentiation, Metabolism and Contraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  5. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  6. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Cavitation noise from butterfly valves

    International Nuclear Information System (INIS)

    Rahmeyer, W.J.

    1982-01-01

    Cavitation in valves can produce levels of intense noise. It is possible to mathematically express a limit for a design level of cavitation noise in terms of the cavitation parameter sigma. Using the cavitation parameter or limit, it is then possible to calculate the flow conditions at which a design level of cavitation noise will occur. However, the intensity of cavitation increases with the upstream pressure and valve size at a constant sigma. Therefore, it is necessary to derive equations to correct or scale the cavitation limit for the effects of different upstream pressures and valve sizes. The following paper discusses and presents experimental data for the caviation noise limit as well as the cavitation limits of incipient, critical, incipient damage, and choking cavitation for butterfly valves. The main emphasis is on the design limit of caviation noise, and a noise level of 85 decibels was selected as the noise limit. Tables of data and scaling exponents are included for applying the design limits for the effects of upstream pressure and valve size. (orig.)

  8. Plunger with simple retention valve

    International Nuclear Information System (INIS)

    Fekete, A.V.

    1987-01-01

    This patent describes a positive displacement retention valve apparatus in which the actual flow equals the theoretical maximum flow through the retention valve. The apparatus includes, in combination, a confined fluid flow conduit, a piston adapted for reciprocal movement within the fluid flow conduit between upstream and downstream limit positions, piston reciprocating means, and pressure responsive check valve means located upstream with respect to the piston in the fluid flow conduit. The pressure responsive check valve means operable to permit fluid flow therethrough in a downstream direction toward the piston, and to preclude fluid flow therethrough in an opposite direction. The piston is composed of parts which are relatively movable with respect to one another. The piston includes a simple retention valve consisting of a plug means, a cylinder having a minimum and a maximum internal cross section flow area therein and being reciprocal within the confined fluid flow conduit, and a seat on the cylinder for the plug means. The piston reciprocating means are operatively connected to the plug means

  9. Automated Text Markup for Information Retrieval from an Electronic Textbook of Infectious Disease

    Science.gov (United States)

    Berrios, Daniel C.; Kehler, Andrew; Kim, David K.; Yu, Victor L.; Fagan, Lawrence M.

    1998-01-01

    The information needs of practicing clinicians frequently require textbook or journal searches. Making these sources available in electronic form improves the speed of these searches, but precision (i.e., the fraction of relevant to total documents retrieved) remains low. Improving the traditional keyword search by transforming search terms into canonical concepts does not improve search precision greatly. Kim et al. have designed and built a prototype system (MYCIN II) for computer-based information retrieval from a forthcoming electronic textbook of infectious disease. The system requires manual indexing by experts in the form of complex text markup. However, this mark-up process is time consuming (about 3 person-hours to generate, review, and transcribe the index for each of 218 chapters). We have designed and implemented a system to semiautomate the markup process. The system, information extraction for semiautomated indexing of documents (ISAID), uses query models and existing information-extraction tools to provide support for any user, including the author of the source material, to mark up tertiary information sources quickly and accurately.

  10. Automated electronic reminders to facilitate primary cardiovascular disease prevention: randomised controlled trial

    Science.gov (United States)

    Holt, Tim A; Thorogood, Margaret; Griffiths, Frances; Munday, Stephen; Friede, Tim; Stables, David

    2010-01-01

    Background Primary care databases contain cardiovascular disease risk factor data, but practical tools are required to improve identification of at-risk patients. Aim To test the effects of a system of electronic reminders (the ‘e-Nudge’) on cardiovascular events and the adequacy of data for cardiovascular risk estimation. Design of study Randomised controlled trial. Setting Nineteen general practices in the West Midlands, UK. Method The e-Nudge identifies four groups of patients aged over 50 years on the basis of estimated cardiovascular risk and adequacy of risk factor data in general practice computers. Screen messages highlight individuals at raised risk and prompt users to complete risk profiles where necessary. The proportion of the study population in the four groups was measured, as well as the rate of cardiovascular events in each arm after 2 years. Results Over 38 000 patients' electronic records were randomised. The intervention led to an increase in the proportion of patients with sufficient data who were identifiably at risk, with a difference of 1.94% compared to the control group (95% confidence interval [CI] = 1.38 to 2.50, P<0.001). A corresponding reduction occurred in the proportion potentially at risk but requiring further data for a risk estimation (difference = –3.68%, 95% CI = –4.53 to –2.84, P<0.001). No significant difference was observed in the incidence of cardiovascular events (rate ratio = 0.96, 95% CI = 0.85 to 1.10, P = 0.59). Conclusion Automated electronic reminders using routinely collected primary care data can improve the adequacy of cardiovascular risk factor information during everyday practice and increase the visibility of the at-risk population. PMID:20353659

  11. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive......: A total of 173 patients were diagnosed with SVD by echocardiography. Of these, 64 (11%) patients had severe SVD and 109 (19%) patients moderate SVD. Severe SVD was associated with the age of the prosthesis and small prosthesis size [Size 21: hazard ratio (95% confidence interval, CI) 2.72 (0.97-8.56), P...

  12. Engineering of a polymer layered bio-hybrid heart valve scaffold

    Energy Technology Data Exchange (ETDEWEB)

    Jahnavi, S., E-mail: jani84@gmail.com [Stem Cell and Molecular Biology Laboratory, Department of Biotechnology, Indian Institute of Technology Madras, Chennai 600036, TN (India); Tissue Culture Laboratory, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Poojappura, Trivandrum, Kerala 695012 (India); Kumary, T.V., E-mail: tvkumary@yahoo.com [Tissue Culture Laboratory, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Poojappura, Trivandrum, Kerala 695012 (India); Bhuvaneshwar, G.S., E-mail: gs.bhuvnesh@gmail.com [Trivitron Innovation Centre, Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, TN (India); Natarajan, T.S., E-mail: tsniit@gmail.com [Conducting Polymer laboratory, Department of Physics, Indian Institute of Technology, Madras, Chennai 600036, TN (India); Verma, R.S., E-mail: vermars@iitm.ac.in [Stem Cell and Molecular Biology Laboratory, Department of Biotechnology, Indian Institute of Technology Madras, Chennai 600036, TN (India)

    2015-06-01

    Current treatment strategy for end stage valve disease involves either valvular repair or replacement with homograft/mechanical/bioprosthetic valves. In cases of recurrent stenosis/ regurgitation, valve replacement is preferred choice of treatment over valvular repair. Currently available mechanical valves primarily provide durability whereas bioprosthetic valves have superior tissue compatibility but both lack remodelling and regenerative properties making their utility limited in paediatric patients. With advances in tissue engineering, attempts have been made to fabricate valves with regenerative potential using various polymers, decellularized tissues and hybrid scaffolds. To engineer an ideal heart valve, decellularized bovine pericardium extracellular matrix (DBPECM) is an attractive biocompatible scaffold but has weak mechanical properties and rapid degradation. However, DBPECM can be modified with synthetic polymers to enhance its mechanical properties. In this study, we developed a Bio-Hybrid scaffold with non-cross linked DBPECM in its native structure coated with a layer of Polycaprolactone-Chitosan (PCL-CH) nanofibers that displayed superior mechanical properties. Surface and functional studies demonstrated integration of PCL-CH to the DBPECM with enhanced bio and hemocompatibility. This engineered Bio-Hybrid scaffold exhibited most of the physical, biochemical and functional properties of the native valve that makes it an ideal scaffold for fabrication of cardiac valve with regenerative potential. - Highlights: • A Bio-Hybrid scaffold was fabricated with PCL-CH blend and DBPECM. • PCL-CH functionally interacted with decellularized matrix without cross linking. • Modified scaffold exhibited mechanical properties similar to native heart valve. • Supported better fibroblast and endothelial cell adhesion and proliferation. • The developed scaffold can be utilized for tissue engineering of heart valve.

  13. Valvular Disorders in Carcinoid Heart Disease

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    Full Text Available Abstract Carcinoid heart disease is a rare but important cause of intrinsic right heart valve disorders leading to right heart failure. Occasionally, left-sided heart valves may also be involved. The characteristic cardiac pathological findings of carcinoid heart disease are endocardial thickening as a result of fibrous deposits on the endocardium. Echocardiographic examination and right heart catheterization are very useful for the diagnosis of the lesion. If more cardiac valves are affected, multiple valve replacement should be considered. The management of the pulmonary valve lesion depends on the extent of the diseased valve, either by valvulotomy, valvectomy, or valve replacement. Percutaneous valve implantations in the pulmonary and in the inferior vena cava positions have been advocated for high-risk patients.

  14. Early outcome of mini aortic valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Shawky Fareed

    2018-03-01

    Full Text Available Background: Minimally invasive aortic valve surgery (MIAVS has evolved into a well-tolerated, efficient surgical treatment option in experienced centers, providing greater patient satisfaction and lower complication rates. Potential advantages of MIAVR arise from the concept that patient morbidity and potential mortality could be reduced without compromising the excellent results of the conventional procedure which include improved cosmetic results, safer access in the case of reoperation, less postoperative bleeding, lower intensive care unit (ICU and in-hospital stays, as well as the absence of sternal wound infection. These results were achievable also in high-risk patients. Reduced pain and hospital length of stay, decreased time until return to full activity and decreased blood product use have also been demonstrated. Methods: Sixty patients with aortic valve disease randomized into two equal groups; group “A” underwent aortic valve surgery through a minimally invasive limited upper sternotomy. Group “B” underwent aortic valve surgery through a full median sternotomy. The Pain was evaluated on 2nd, 3rd day post-operatively and at the 3rd, 6th month after discharge. Echocardiographic data were performed preoperatively and at the 3rd, 6th month after discharge in all patients. Standard aortic and bicaval cannulation with cold antegrade crystalloid cardioplegia was adopted in group“B”, while in group “A” femoral vein with ascending aortic cannulation was adopted with antegrade blood cardioplegia. Results: There was no statistical difference between the two groups preoperatively regarding their age, sex, NYHA class, EF%, LA dimension, spirometric study. There was no operative mortality in both groups but few postoperative complications occurred in both groups. Total hospital stay, ICU stay, postoperative bleeding, inotropic requirement, ventilatory support, blood transfusion was less in group “A”, with better cosmetic

  15. Is there a role for surgeons in transcatheter mitral valve procedures?

    Science.gov (United States)

    Buch, Mamta H; Trento, Alfredo; Kar, Saibal

    2011-03-01

    The rapid advancement in transcatheter therapies seeks to provide less invasive options compared with conventional surgery in the treatment of acquired valvular heart disease. A number of transcatheter mitral valve devices using a variety of approaches for the treatment of mitral regurgitation are under development or in early clinical application. Although yet to be clearly defined, there is no doubt that transcatheter mitral valve procedures will have a significant role alongside conventional surgery. The question is: will surgeons, who have led the treatment of mitral valve disease for the past 30 years, have a role in these procedures? In order to answer this question, this review discusses key understanding of mitral valve anatomy, function and disorder required to perform transcatheter mitral valve interventions. It assesses the potential role of transcatheter therapies with particular reference to percutaneous edge-to-edge repair using the Mitraclip system (Abbott Vascular Devices, California, USA). The new era in collaboration between surgeons and cardiologists is discussed and the potential role of the surgeon in percutaneous mitral valve procedures is examined. Transcatheter mitral valve procedures demand increasing collaboration between cardiologists and surgeons in order to achieve optimal outcomes. Interventional cardiologists will require dedicated training in the specialized field of transcatheter interventions in acquired structural heart diseases. As the delivery of such therapies brings the interface between interventional cardiology and cardiac surgery ever closer, there is the potential for a niche area in cardiac surgery to develop comprising minimally invasive surgical and transcatheter skills.

  16. Electronic beam CT diagnosis of infant congenital heart disease with the comparison of echocardiogram and operation

    International Nuclear Information System (INIS)

    Li Xiangmin; Zhou Xuhui; Yang Youyou; Meng Quanfei; Peng Qian; Tan Zhiyu

    2003-01-01

    Objective: To explore the advantage and limitation in the diagnosis of infant congenital heart disease (CHD) by electron beam computed tomography (EBCT). Methods: Eighty patients suspected or diagnosed as infant CHD underwent dynamic contrast enhanced EBCT imaging. EBCT imaging was carried out in two steps: single slice mode scanning and multiple slice mode scanning. The EBCT results of 80 cases were correlated with echocardiogram and operation records. 39 cases were confirmed by surgery. Chi-Square test was used for statistical analysis. Results: Among 80 patients, there were 27 cases in non-cyanosis and 53 cases in cyanosis. In this group including 16 types of CHD, 206 malformations were revealed with EBCT while 159 abnormalities with echocardiogram. 101 lesions were proved by surgery, which demonstrated a diagnosis accuracy of 96% (97/101) with EBCT, and 87% (88/101) with echocardiogram. A statistical significant difference was observed between the two methods (χ 2 =6.231, P<0.01). Conclusion: EBCT scanning can demonstrate the pathological morphology of CHD, especially, EBCT is helpful in the sequential segmental analysis in complex CHD. It is better than echocardiogram in demonstrating the aortic congenital disease and pulmonary artery development and anomalous pulmonary venous drainage

  17. Predicting changes in hypertension control using electronic health records from a chronic disease management program

    Science.gov (United States)

    Sun, Jimeng; McNaughton, Candace D; Zhang, Ping; Perer, Adam; Gkoulalas-Divanis, Aris; Denny, Joshua C; Kirby, Jacqueline; Lasko, Thomas; Saip, Alexander; Malin, Bradley A

    2014-01-01

    Objective Common chronic diseases such as hypertension are costly and difficult to manage. Our ultimate goal is to use data from electronic health records to predict the risk and timing of deterioration in hypertension control. Towards this goal, this work predicts the transition points at which hypertension is brought into, as well as pushed out of, control. Method In a cohort of 1294 patients with hypertension enrolled in a chronic disease management program at the Vanderbilt University Medical Center, patients are modeled as an array of features derived from the clinical domain over time, which are distilled into a core set using an information gain criteria regarding their predictive performance. A model for transition point prediction was then computed using a random forest classifier. Results The most predictive features for transitions in hypertension control status included hypertension assessment patterns, comorbid diagnoses, procedures and medication history. The final random forest model achieved a c-statistic of 0.836 (95% CI 0.830 to 0.842) and an accuracy of 0.773 (95% CI 0.766 to 0.780). Conclusions This study achieved accurate prediction of transition points of hypertension control status, an important first step in the long-term goal of developing personalized hypertension management plans. PMID:24045907

  18. Predicting changes in hypertension control using electronic health records from a chronic disease management program.

    Science.gov (United States)

    Sun, Jimeng; McNaughton, Candace D; Zhang, Ping; Perer, Adam; Gkoulalas-Divanis, Aris; Denny, Joshua C; Kirby, Jacqueline; Lasko, Thomas; Saip, Alexander; Malin, Bradley A

    2014-01-01

    Common chronic diseases such as hypertension are costly and difficult to manage. Our ultimate goal is to use data from electronic health records to predict the risk and timing of deterioration in hypertension control. Towards this goal, this work predicts the transition points at which hypertension is brought into, as well as pushed out of, control. In a cohort of 1294 patients with hypertension enrolled in a chronic disease management program at the Vanderbilt University Medical Center, patients are modeled as an array of features derived from the clinical domain over time, which are distilled into a core set using an information gain criteria regarding their predictive performance. A model for transition point prediction was then computed using a random forest classifier. The most predictive features for transitions in hypertension control status included hypertension assessment patterns, comorbid diagnoses, procedures and medication history. The final random forest model achieved a c-statistic of 0.836 (95% CI 0.830 to 0.842) and an accuracy of 0.773 (95% CI 0.766 to 0.780). This study achieved accurate prediction of transition points of hypertension control status, an important first step in the long-term goal of developing personalized hypertension management plans.

  19. Valve microstructure and phylomineralogy of New Zealand chitons.

    Science.gov (United States)

    Peebles, B A; Smith, A M; Spencer, H G

    2017-03-01

    The microstructure and mineralogy of chiton valves has been largely ignored in the literature and only described in 29 species to date. Eight species: Acanthochitona zelandica, Notoplax violacea (Family Acanthochitonidae, Suborder Acanthochitonina, Order Chitonida), Chiton glaucus, Onithochiton neglectus, Sypharochiton spelliserpentis, Sypharochiton sinclairi (Family Chitonidae, Suborder, Chitonina, Order Chitonida), Ischnochiton maorianus (Family Ischnochitonidae, Suborder Chitonina, Order Chitonida), and Leptochiton inquinatus (Family Leptochitonidae, Suborder Lepidopleurina, Order Lepidopleurida) were collected from the Otago Peninsula, South Island, New Zealand. The valves of these chitons were analysed with X-ray diffractometry, Raman spectrometry, and Scanning Electron Micrography (SEM) to determine their mineralogy and microstructure. Both the XRD and Raman data show that the valves consisted solely of aragonite. The observed microstructures of the valves were complex, typically composed of four to seven sublayers, and varied among species. The dorsal layer, the tegmentum, of each species was granular and the ventral layer, the articulamentum, was predominately composed of a spherulitic sublayer, a crossed lamellar sublayer, and an acicular sublayer. The chitonids Sypharochiton pelliserpentis and S. sinclairi had the most complex microstructure layering with three crossed lamellar, two spherulitic sublayers, and a ventral acicular sublayer while the acanthochitonids Acanthochitona zelandica and Notoplax violacea as well as the ischnochitonid Ischnochiton maorianus had the simplest structure with one spherulitic, one crossed lamellar sublayer, and a ventral acicular sublayer. Terminal valves were less complex than intermediate valves and tended to be dominated by the crossed lamellar structure. The leptochitonid Leptochiton inquinatus generated a unique crossed lamellar sublayer different from the other analysed chitonids. Acanthochitona zelandica is the only

  20. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetati