  1. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Development and Validation of a Stability-Indicating LC-UV Method for Simultaneous Determination of Ketotifen and Cetirizine in Pharmaceutical Dosage Forms. ... 5 μm) using an isocratic mobile phase that consisted of acetonitrile and 10 mM disodium hydrogen phosphate buffer (pH 6.5) in a ratio of 45:55 % v/v at a flow ...

  2. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    Science.gov (United States)

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  3. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    Science.gov (United States)

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  4. Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

    Directory of Open Access Journals (Sweden)

    Raphael Hösli

    2018-01-01

    Full Text Available Phenytoin (PHT is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis, and resulted in a better LOD ( 0.995 for all tested matrices (blood, saliva, and dialysate. For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.

  5. Development and Validation of a Novel LC-MS/MS Opioid Confirmation Assay: Evaluation of β-glucuronidase Enzymes and Sample Cleanup Methods.

    Science.gov (United States)

    Yang, He S; Wu, Alan H B; Lynch, Kara L

    2016-06-01

    With the rise in the use and misuse of prescription opioids, there is an increasing need for the confirmed identification of opioid analgesics in toxicology laboratories. The goals of this study were to (i) systematically evaluate the hydrolysis efficiency of four β-glucuronidase enzymes under optimized condition; (ii) evaluate compound recovery, matrix effects and precision of three protein precipitation plates and (iii) develop and validate a qualitative liquid-chromatography mass spectrometry (LC-MS/MS) assay to identify 13 opioids in urine. A recombinant β-glucuronidase exhibited the best overall hydrolysis efficiency for seven opioid glucuronide conjugates compared with β-glucuronidase from red abalone, Escherichia coli and Patella vulgata One of the protein precipitation plates tested exhibited overall better recovery of the opioids and lower ion suppression compared with the other two plates. An ESI positive mode LC-MS/MS assay for qualitative opioid analysis was developed and validated. Linearity, LOD, precision, matrix effect, recovery, carryover and interference of the method were evaluated. Sixty-two patient samples were analyzed by both a legacy GC-MS opioid method and the LC-MS/MS method, and 22 samples were analyzed by the LC-MS/MS and an LC-MS/MS reference method. The results of the comparisons showed good concordance. Overall, we described an efficient sample preparation procedure for a sensitive qualitative opioid confirmation assay in urine. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method.

    Science.gov (United States)

    Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini

    2009-02-15

    An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.

  7. Validated LC-MS/MS Method for the Quantification of Free and Bound Lignans in Cereal-Based Diets and Feces

    DEFF Research Database (Denmark)

    Nørskov, Natalja; Knudsen, Knud Erik Bach

    2016-01-01

    lignans (matairesinol, hydroxymatairesinol, secoisolariciresinol, lariciresinol, isolariciresinol, syringaresinol, medioresinol, and pinoresinol) and two enterolignans (enterodiol and enterolactone) in cereal-based diets/bread and feces. The method consisted of alkaline methanolic extraction combined......Despite the extensive literature describing the biological effects of phenolic compounds from cereals, little is known about their bioaccessibility in the food matrix. This paper describes a validated LC-MS/MS method for the quantification of free and total content (free + bound) of eight plant...

  8. Single Laboratory Validated Method for Determination of Cylindrospermopsin and Anatoxin-a in Ambient Water by Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)

    Science.gov (United States)

    This product is an LC/MS/MS single laboratory validated method for the determination of cylindrospermopsin and anatoxin-a in ambient waters. The product contains step-by-step instructions for sample preparation, analyses, preservation, sample holding time and QC protocols to ensu...

  9. Development and Validation of a Precise and Stability Indicating LC Method for the Determination of Benzalkonium Chloride in Pharmaceutical Formulation Using an Experimental Design

    Directory of Open Access Journals (Sweden)

    Harshal K. Trivedi

    2010-01-01

    Full Text Available A simple, precise, shorter runtime and stability indicating reverse-phase high performance liquid chromatographic method has been developed and validated for the quantification of benzalkonium chloride (BKC preservative in pharmaceutical formulation of sparfloxacin eye drop. The method was successfully applied for determination of benzalkonium chloride in various ophthalmic formulations like latanoprost, timolol, dexametasone, gatifloxacin, norfloxacin, combination of moxifloxacin and dexamethasone, combination of nepthazoline HCl, zinc sulphate and chlorpheniramine maleate, combination of tobaramycin and dexamethasone, combination of phenylephrine HCl, naphazoline HCl, menthol and camphor. The RP-LC separation was achieved on an Purospher Star RP-18e 75 mm × 4.0 mm, 3.0 μ in the isocratic mode using buffer: acetonitrile (35: 65, v/v, as the mobile phase at a flow rate of 1.8 mL/min. The methods were performed at 215 nm; in LC method, quantification was achieved with PDA detection over the concentration range of 50 to 150 μg/mL. The method is effective to separate four homologs with good resolution in presence of excipients, sparfloxacin and degradable compound due to sparfloxacin and BKC within five minutes. The method was validated and the results were compared statistically. They were found to be simple, accurate, precise and specific. The proposed method was validated in terms of specificity, precision, recovery, solution stability, linearity and range. All the validation parameters were within the acceptance range and concordant to ICH guidelines.

  10. Validation and implementation of liquid chromatographic-mass spectrometric (LC-MS) methods for the quantification of tenofovir prodrugs.

    Science.gov (United States)

    Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A

    2018-04-15

    The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also

  11. Mycotoxin and fungicide residues in wheat grains from fungicide-treated plants measured by a validated LC-MS method.

    Science.gov (United States)

    da Luz, Suzane Rickes; Pazdiora, Paulo Cesar; Dallagnol, Leandro José; Dors, Giniani Carla; Chaves, Fábio Clasen

    2017-04-01

    Wheat (Triticum aestivum) is an annual crop, cultivated in the winter and spring and susceptible to several pathogens, especially fungi, which are managed with fungicides. It is also one of the most consumed cereals, and can be contaminated by mycotoxins and fungicides. The objective of this study was to validate an analytical method by LC-MS for simultaneous determination of mycotoxins and fungicide residues in wheat grains susceptible to fusarium head blight treated with fungicides, and to evaluate the relationship between fungicide application and mycotoxin production. All parameters of the validated analytical method were within AOAC and ANVISA limits. Deoxynivalenol was the prevalent mycotoxin in wheat grain and epoxiconazole was the fungicide residue found in the highest concentration. All fungicidal treatments induced an increase in AFB2 production when compared to the control (without application). AFB1 and deoxynivalenol, on the contrary, were reduced in all fungicide treatments compared to the control. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Validation Study on a Rapid Method for Simultaneous Determination of Pesticide Residues in Vegetables and Fruits by LC-MS/MS.

    Science.gov (United States)

    Sato, Tamaki; Miyamoto, Iori; Uemura, Masako; Nakatani, Tadashi; Kakutani, Naoya; Yamano, Tetsuo

    2016-01-01

    A validation study was carried out on a rapid method for the simultaneous determination of pesticide residues in vegetables and fruits by LC-MS/MS. Preparation of the test solution was performed by a solid-phase extraction technique with QuEChERS (STQ method). Pesticide residues were extracted with acetonitrile using a homogenizer, followed by salting-out and dehydration at the same time. The acetonitrile layer was purified with C18 and PSA mini-columns. The method was assessed for 130 pesticide residues in 14 kinds of vegetables and fruits at the concentration level of 0.01 μg/g according to the method validation guideline of the Ministry of Health, Labour and Welfare of Japan. As a result 75 to 120 pesticide residues were determined satisfactorily in the tested samples. Thus, this method could be useful for a rapid and simultaneous determination of multi-class pesticide residues in various vegetables and fruits.

  13. Matrix Effect Evaluation and Method Validation of Azoxystrobin and Difenoconazole Residues in Red Flesh Dragon Fruit (Hylocereus polyrhizus) Matrices Using QuEChERS Sample Preparation Methods Followed by LC-MS/MS Determination.

    Science.gov (United States)

    Noegrohati, Sri; Hernadi, Elan; Asviastuti, Syanti

    2018-03-30

    Production of red flesh dragon fruit (Hylocereus polyrhizus) was hampered by Colletotrichum sp. Pre-harvest application of azoxystrobin and difenoconazole mixture is recommended, therefore, a selective and sensitive multi residues analytical method is required in monitoring and evaluating the commodity's safety. LC-MS/MS is a well-established analytical technique for qualitative and quantitative determination in complex matrices. However, this method is hurdled by co-eluted coextractives interferences. This work evaluated the pH effect of acetate buffered and citrate buffered QuEChERS sample preparation in their effectiveness of matrix effect reduction. Citrate buffered QuEChERS proved to produce clean final extract with relative matrix effect 0.4%-0.7%. Method validation of the selected sample preparation followed by LC-MS/MS for whole dragon fruit, flesh and peel matrices fortified at 0.005, 0.01, 0.1 and 1 g/g showed recoveries 75%-119%, intermediate repeatability 2%-14%. The expanded uncertainties were 7%-48%. Based on the international acceptance criteria, this method is valid.

  14. ESI-MSn and LC-ESI-MS studies to characterize forced degradation products of bosentan and a validated stability-indicating LC-UV method.

    Science.gov (United States)

    Bansal, Gulshan; Singh, Ranjit; Saini, Balraj; Bansal, Yogita

    2013-01-01

    The present study reports the characterization of forced degradation products of bosentan and a validated stability-indicating HPLC method for the stability testing of bosentan tablets. The forced degradation was carried out under the conditions of hydrolysis, oxidation, dry heat and photolysis. The drug was found unstable in acid, alkali and oxidative media whereas stable to the hydrolysis in water, to dry heat and to photolysis. In total, six degradation products were formed in all conditions which were resolved in a single run on a C-18 column with gradient elution using ammonium acetate buffer (pH 4.5, 5.0mM), methanol and acetonitrile. Structures of all the degradation products were characterized through +ESI-MS(n) and LC-ESI-MS spectral data of bosentan as well as LC-ESI-MS spectral data of the products. The products II-VI were characterized as 6-amino-[2,2']bipyrimidinyl-4,5-diol, 6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-ol, 2-[6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yloxy]-ethanol, 4-tert-butyl-N-[6-(1-methoxyethoxy)-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yl]-benzenesulfonamide and 4-tert-butyl-N-[6-hydroxy-5-(2-methoxyphenoxy)-[2,2']bipyrimidinyl-4-yl]-benzenesulfonamide, respectively. The peak of the product I was found to be due to two secondary degradation products which co-eluted and were characterized as β-hydroxyethyl p-tert-butylphenylsulfonate (Ia) and 2-[2-(2-hydroxyethoxy)-phenoxy]-ethanol (Ib). These products were formed due to hydrolysis of sulfonamide and alkylaryl ether and the diaryl ether linkages as well as dehydration of the primary alcohol group. The most probable degradation mechanisms were proposed. The HPLC method was found to be stability-indicating, linear (2-100 μg ml(-1)), accurate, precise, sensitive, specific, rugged and robust for quantitation of the drug. The method was applied to the stability testing of the commercially available bosentan tablets successfully. Copyright © 2012 Elsevier B.V. All

  15. Validation of a LC/MS method for the determination of gemfibrozil in human plasma and its application to a pharmacokinetic study

    Science.gov (United States)

    Rower, Joseph E.; Bushman, Lane R.; Hammond, Kyle P.; Kadam, Rajendra S.; Aquilante, Christina L.

    2011-01-01

    Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate, and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6% and 10.7%, and inter-assay precision ranging from 4.4% to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6% and 108.7% of the expected value, and inter-assay concentrations within 89.4 to 104.0% of the expected value. The linear concentration range was between 0.5 and 50 μg/mL with a lower limit of quantitation of 0.5 μg/mL when 125 μL of plasma were extracted. This LC/MS method yielded a quick, simple, and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. PMID:21077249

  16. Validation of an LC/MS method for the determination of gemfibrozil in human plasma and its application to a pharmacokinetic study.

    Science.gov (United States)

    Rower, Joseph E; Bushman, Lane R; Hammond, Kyle P; Kadam, Rajendra S; Aquilante, Christina L

    2010-12-01

    Gemfibrozil, a fibric acid hypolipidemic agent, is increasingly being used in clinical drug-drug interaction studies as an inhibitor of drug metabolizing enzymes and drug transporters. The validation of a fast, accurate and precise LC/MS method is described for the quantitative determination of gemfibrozil in an EDTA-anticoagulated human plasma matrix. Briefly, gemfibrozil was extracted from human plasma by an acetonitrile protein precipitation method. The assay was reproducible with intra-assay precision between 1.6 and 10.7%, and inter-assay precision ranging from 4.4 to 7.8%. The assay also showed good accuracy, with intra-assay concentrations within 85.6-108.7% of the expected value, and inter-assay concentrations within 89.4-104.0% of the expected value. The linear concentration range was between 0.5 and 50 µg/mL with a lower limit of quantitation of 0.5 µg/mL when 125 µL of plasma were extracted. This LC/MS method yielded a quick, simple and reliable protocol for determining gemfibrozil concentrations in plasma and is applicable to clinical pharmacokinetic studies. Copyright © 2010 John Wiley & Sons, Ltd.

  17. Development and validation of a simple, rapid and sensitive LC-MS/MS method for the measurement of urinary neurotransmitters and their metabolites.

    Science.gov (United States)

    Yan, Jingya; Kuzhiumparambil, Unnikrishnan; Bandodkar, Sushil; Solowij, Nadia; Fu, Shanlin

    2017-12-01

    Neurotransmitters play crucial roles in physiological functions and their imbalances have demonstrated association in the pathology of several diseases. The measurement of neurotransmitters possesses a great potential as a significant clinical tool. This study presents the development and validation of an LC-MS/MS method for simultaneous quantification of multi-class neurotransmitters associated with dopamine, tryptophan and glutamate-γ-aminobutyric acid pathways. A total of ten neurotransmitters and their metabolites (dopamine, epinephrine, metanephrine, tryptophan, serotonin, kynurenic acid, kynurenine, anthranilic acid, GABA, glutamic acid) were determined based on a simple and rapid 'dilute and shoot' method using minimal urine volume. The chromatographic separation was achieved using a Poroshell 120 Bonus-RP LC Column in combination with a gradient elution within an 8.5-min time frame. The method exhibited good sensitivity as the limits of quantification ranged between 0.025 and 0.075 μg/mL with acceptable matrix effects ( 0.98). The accuracy and precision for all analytes were within tolerances, at neurotransmitter concentrations in urine of healthy donors. Furthermore, the undertaken stability experiments indicated that acidified urine specimens allowed the analytes to be stable for prolonged durations in comparison to those untreated. The study also reveals the performance of the method is unaffected by the absence of expensive deuterated reference standards under the experimental conditions employed which further simplifies the analytical procedures and provides a significant cost saving for running the assay. Graphical abstract The quantification of multi-class neurotransitters associated with the dopamine, tryptophan and GABA-glutamate pathways using a simple 'dilute and shoot' LC-MS/MS method.

  18. Sewage-based epidemiology in monitoring the use of new psychoactive substances: Validation and application of an analytical method using LC-MS/MS.

    Science.gov (United States)

    Kinyua, Juliet; Covaci, Adrian; Maho, Walid; McCall, Ann-Kathrin; Neels, Hugo; van Nuijs, Alexander L N

    2015-09-01

    Sewage-based epidemiology (SBE) employs the analysis of sewage to detect and quantify drug use within a community. While SBE has been applied repeatedly for the estimation of classical illicit drugs, only few studies investigated new psychoactive substances (NPS). These compounds mimic effects of illicit drugs by introducing slight modifications to chemical structures of controlled illicit drugs. We describe the optimization, validation, and application of an analytical method using liquid chromatography coupled to positive electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of seven NPS in sewage: methoxetamine (MXE), butylone, ethylone, methylone, methiopropamine (MPA), 4-methoxymethamphetamine (PMMA), and 4-methoxyamphetamine (PMA). Sample preparation was performed using solid-phase extraction (SPE) with Oasis MCX cartridges. The LC separation was done with a HILIC (150 x 3 mm, 5 µm) column which ensured good resolution of the analytes with a total run time of 19 min. The lower limit of quantification (LLOQ) was between 0.5 and 5 ng/L for all compounds. The method was validated by evaluating the following parameters: sensitivity, selectivity, linearity, accuracy, precision, recoveries and matrix effects. The method was applied on sewage samples collected from sewage treatment plants in Belgium and Switzerland in which all investigated compounds were detected, except MPA and PMA. Furthermore, a consistent presence of MXE has been observed in most of the sewage samples at levels higher than LLOQ. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Rapid Determination of Isomeric Benzoylpaeoniflorin and Benzoylalbiflorin in Rat Plasma by LC-MS/MS Method

    Directory of Open Access Journals (Sweden)

    Chuanqi Zhou

    2017-01-01

    Full Text Available Benzoylpaeoniflorin (BP is a potential therapeutic agent against oxidative stress related Alzheimer’s disease. In this study, a more rapid, selective, and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS method was developed to determine BP in rat plasma distinguishing with a monoterpene isomer, benzoylalbiflorin (BA. The method showed a linear response from 1 to 1000 ng/mL (r>0.9950. The precision of the interday and intraday ranged from 2.03 to 12.48% and the accuracy values ranged from −8.00 to 10.33%. Each running of the method could be finished in 4 minutes. The LC-MS/MS method was validated for specificity, linearity, precision, accuracy, recovery, and stability and was found to be acceptable for bioanalytical application. Finally, this fully validated method was successfully applied to a pharmacokinetic study in rats following oral administration.

  20. Fingerprinting and validation of a LC-DAD method for the analysis of biflavanones in Garcinia kola-based antimalarial improved traditional medicines.

    Science.gov (United States)

    Tshibangu, P Tshisekedi; Kapepula, P Mutwale; Kapinga, M J Kabongo; Lupona, H Kabika; Ngombe, N Kabamba; Kalenda, Dibungi T; Jansen, O; Wauters, J N; Tits, M; Angenot, L; Rozet, E; Hubert, Ph; Marini, R D; Frédérich, M

    2016-09-05

    African populations use traditional medicines in their initial attempt to treat a range of diseases. Nevertheless, accurate knowledge of the composition of these drugs remains a challenge in terms of ensuring the health of population and in order to advance towards improved traditional medicines (ITMs). In this paper chromatographic methods were developed for qualitative and quantitative analyses of a per os antimalarial ITM containing Garcinia kola. The identified analytical markers were used to establish TLC and HPLC fingerprints. G. kola seeds were analysed by HPLC to confirm the identity of the extract used by the Congolese manufacturer in the ITM. The main compounds (GB1, GB2, GB-1a and Kolaflavanone) were isolated by preparative TLC and identified by UPLC-MS and NMR. For the quantification of the major compound GB1, a simple and rapid experimental design was applied to develop an LC method, and then its validation was demonstrated using the total error strategy with the accuracy profile as a decision tool. The accurate results were observed within 0.14-0.45mg/mL range of GB1 expressed as naringenin. The extracts used in several batches of the analysed oral solutions contained GB1 (expressed as naringenin) within 2.04-2.43%. Both the fingerprints and the validated LC-DAD were found suitable for the quality control of G. kola-based raw material and finished products, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Keywords: Ketotifen, Cetirizine, Stability indicating method, Stressed conditions, Validation. Tropical ... in biological fluids [13] are also reported. Stability indicating HPLC method is reported for ketotifen where drug is ..... paracetamol, cetirizine.

  2. Validation of a method for the determination of 120 pesticide residues in apples and cucumbers by LC-MS/MS.

    Science.gov (United States)

    Ramadan, Gouda; Al Jabir, Muna; Alabdulmalik, Najat; Mohammed, Ali

    2016-05-01

    Most countries have clearly defined regulations governing the use of pesticides in agricultural activity. The application of pesticides in agriculture usually leads to a residual amount of these pesticides on food products such as fruit and vegetables. The presence of pesticide residues on these foods destined for human consumption may pose food safety risks to consumers. To protect consumers, national authorities have established maximum limits for pesticide residues in foods. These limits can only be enforced if there are methods available to detect and monitor their concentrations in the applicable food products. To support the enforcement of this legislation, we have developed a multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of 120 pesticide residues in apples and cucumbers which has been validated and implemented in the routine monitoring and surveillance programme for these pesticides. In this method, apple and cucumber samples are extracted using the QuEChERS method (quick, easy, cheap, effective, rugged, and safe) and the extracts were analyzed directly by LC-MS/MS. The mean recoveries at three different concentrations of 0.01 µg/g , 0.05 µg/g, and 0.1 µg/g over the analytical range varied between 70 and 120%. The repeatability of the method expressed as %RSD was less than 20%. The limit of detection (LOD) of the method ranged between 0.0014 and 0.0110 µg/g for apples and between 0.0012 and 0.0075 µg/g for cucumbers. The limit of quantification (LOQ) of the method was 0.01 µg/g for apples and cucumbers. The method has been used for the analysis of over 600 apple and 550 cucumber samples over the past two years. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Development, validation and comparison of two stability-indicating RP-LC methods using charged aerosol and UV detectors for analysis of lisdexamfetamine dimesylate in capsules

    Directory of Open Access Journals (Sweden)

    Graciela Carlos

    2016-11-01

    Full Text Available Two new stability-indicating liquid chromatographic methods using two detectors, an ultraviolet (UV and a charged aerosol detector (CAD simultaneously connected in series were validated for the assessment of lisdexamfetamine dimesylate (LDX in capsule. The method was optimized and the influence of individual parameters on UV and CAD response and sensitivity was studied. Chromatography was performed on a Zorbax CN column (250 mm × 4.6 mm, 5 μm in an isocratic elution mode, using acetonitrile and 20 mM ammonium formate at pH 4.0 (50:50, v/v as mobile phase and UV detection at 207 nm. The developed method was validated according to ICH guidelines and the parameters’ specificity, limit of detection, limit of quantitation, linearity, accuracy, precision and robustness were evaluated. CAD is designated to be a non-linear detector in a wide dynamic range, however, the method was linear over the concentration range of 70–130 μg mL−1 in both detectors. The method was precise and accurate. Robustness study was performed by a Plackett–Burman design, delivering results within the acceptable range. Neither the excipients nor the degradation products showed interference in the method after studies of specificity as well as under stress conditions. The results of the LC-UV and LC-CAD methods were statistically compared through ANOVA and showed no significant difference (p > 0.05. Both proposed methods could be considered interchangeable and stability-indicating, and can be applied as an appropriate quality control tool for routine analysis of LDX in capsule.

  4. Quantitation of pregabalin in dried blood spots and dried plasma spots by validated LC-MS/MS methods.

    Science.gov (United States)

    Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana

    2015-05-10

    In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50mm×4.0mm, 3μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 2min. Established methods were fully validated over the concentration range of 0.200-20.0μg/mL for DBS and 0.400-40.0μg/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Chemometrically assisted development and validation of LC-MS/MS method for the analysis of potential genotoxic impurities in meropenem active pharmaceutical ingredient.

    Science.gov (United States)

    Grigori, Katerina; Loukas, Yannis L; Malenović, Anđelija; Samara, Vicky; Kalaskani, Anastasia; Dimovasili, Efi; Kalovidouri, Magda; Dotsikas, Yannis

    2017-10-25

    A sensitive Liquid Chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of three potential genotoxic impurities (318BP, M9, S5) in meropenem Active Pharmaceutical Ingredient (API). Due to the requirement for LOD values in ppb range, a high concentration of meropenem API (30mg/mL) had to be injected. Therefore, efficient determination of meropenem from its impurities became a critical aim of this study, in order to divert meropenem to waste, via a switching valve. ‎ After the selection of the important factors affecting analytes' elution, a Box-Behnken design was utilized to set the plan of experiments conducted with UV detector. As responses, the separation factor s between the last eluting impurity and meropenem, as well as meropenem retention factor k were used. Grid point search methodology was implemented aiming to obtain the optimal conditions that simultaneously comply to the conflicted criteria. Optimal mobile phase consisted of ACN, methanol and 0.09% HCOOH at a ratio 71/3.5/15.5v/v. All impurities and internal standard omeprazole were eluted before 7.5min and at 8.0min the eluents were directed to waste. The protocol was transferred to LC-MS/MS and validated according to ICH guidelines. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Development and validation of a bioanalytical LC-MS method for the quantification of GHRP-6 in human plasma.

    Science.gov (United States)

    Gil, Jeovanis; Cabrales, Ania; Reyes, Osvaldo; Morera, Vivian; Betancourt, Lázaro; Sánchez, Aniel; García, Gerardo; Moya, Galina; Padrón, Gabriel; Besada, Vladimir; González, Luis Javier

    2012-02-23

    Growth hormone-releasing peptide 6 (GHRP-6, His-(DTrp)-Ala-Trp-(DPhe)-Lys-NH₂, MW=872.44 Da) is a potent growth hormone secretagogue that exhibits a cytoprotective effect, maintaining tissue viability during acute ischemia/reperfusion episodes in different organs like small bowel, liver and kidneys. In the present work a quantitative method to analyze GHRP-6 in human plasma was developed and fully validated following FDA guidelines. The method uses an internal standard (IS) of GHRP-6 with ¹³C-labeled Alanine for quantification. Sample processing includes a precipitation step with cold acetone to remove the most abundant plasma proteins, recovering the GHRP-6 peptide with a high yield. Quantification was achieved by LC-MS in positive full scan mode in a Q-Tof mass spectrometer. The sensitivity of the method was evaluated, establishing the lower limit of quantification at 5 ng/mL and a range for the calibration curve from 5 ng/mL to 50 ng/mL. A dilution integrity test was performed to analyze samples at higher concentration of GHRP-6. The validation process involved five calibration curves and the analysis of quality control samples to determine accuracy and precision. The calibration curves showed R² higher than 0.988. The stability of the analyte and its internal standard (IS) was demonstrated in all conditions the samples would experience in a real time analyses. This method was applied to the quantification of GHRP-6 in plasma from nine healthy volunteers participating in a phase I clinical trial. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. The validation & verification of an LC/MS method for the determination of total docosahexaenoic acid concentrations in canine blood serum.

    Science.gov (United States)

    Dillon, Gerald Patrick; Keegan, Jason D; Wallace, Geoff; Yiannikouris, Alexandros; Moran, Colm Anthony

    2018-06-01

    Docosahexaenoic acid (DHA), is an omega 3 fatty acid (n-3 FA) that has been shown to play a role in canine growth and physiological integrity and improvements in skin and coat condition. However, potential adverse effects of n-3 FA specifically, impaired cellular immunity has been observed in dogs fed diets with elevated levels of n-3 FA. As such, a safe upper limit (SUL) for total n-3 FAs (DHA and EPA) in dogs has been established. Considering this SUL, sensitive methods detecting DHA in blood serum as a biomarker when conducting n-3 FA supplementation trials involving dogs are required. In this study, an LC-ESI-MS/MS method of DHA detection in dog serum was validated and verified. Recovery of DHA was optimized and parallelism tests were conducted with spiked samples demonstrating that the serum matrix did not interfere with quantitation. The stability of DHA in serum was also investigated, with -80 °C considered suitable when storing samples for up to six months. The method was linear over a calibration range of 1-500 μg/mL and precision and accuracy were found to meet the requirements for validation. This method was verified in an alternative laboratory using a different analytical system and operator, with the results meeting the criteria for verification. Copyright © 2018. Published by Elsevier Inc.

  8. Development and validation of an LC-MS/MS method for the determination of adapalene in pharmaceutical forms for skin application

    Directory of Open Access Journals (Sweden)

    Dobričić Vladimir

    2016-01-01

    Full Text Available Development and validation of a liquid chromatography - tandem mass spectrometry (LC-MS/MS method for the determination of adapalene in pharmaceutical forms for skin application were presented. The MS/MS analysis of adapalene was performed by use of three mobile phases, consisted of acetonitrile and (a 0.1 % formic acid, (b 0.1 % trifluoroacetic acid and (c 20 mM ammonium acetate. The strongest signals of parent ion and dominant product ion were obtained in negative mode by use of the mobile phase (c. Validation of this method was performed according to the ICH guidelines. Small variations of selected chromatographic parameters (concentration of ammonium acetate, mobile phase composition, column temperature and flow rate did not affect qualitative and quantitative system responses significantly, which proved method’s robustness. The method is specific for the determination of adapalene. Linearity was proved in the concentration range 6.7 - 700.0 ng mL-1 (r = 0.9990, with limits of detection and quantification 2.0 ng mL-1 and 6.7 ng mL-1, respectively. Accuracy was confirmed by calculated recoveries (98.4 % - 101.5 %. Precision was tested at three levels: injection repeatability, analysis repeatability and intermediate precision. Calculated relative standard deviations were less than 1, 2 and 3 %, respectively. [Projekat Ministartsva nauke Republike Srbije, br. OI172041 i br. TR34031

  9. Development and validation of a LC-MS/MS method for the determination of clebopride and its application to a pharmacokinetics study in healthy Chinese volunteers.

    Science.gov (United States)

    Tan, Zhirong; Ouyang, Dongsheng; Chen, Yao; Zhou, Gan; Cao, Shan; Wang, Yicheng; Peng, Xiujuan; Zhou, Honghao

    2010-08-01

    A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the identification and quantification of clebopride in human plasma using itopride as an internal standard. The method involves a simple liquid-liquid extraction. The analytes were separated by isocratic gradient elution on a CAPCELL MG-III C(18) (5 microm, 150 mm x 2.1 mm i.d.) column and analyzed in multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI) interface using the respective [M+H](+) ions, m/z 373.9-->m/z184.0 for clebopride, m/z 359.9-->m/z71.5 for itopride. The method was validated over the concentration range of 69.530-4450.0 pg/ml for clebopride. Within- and between-batch precision (RSD%) was all within 6.83% and accuracy ranged from -8.16 to 1.88%. The LLOQ was 69.530 pg/ml. The extraction recovery was on an average 77% for clebopride. The validated method was used to study the pharmacokinetics profile of clebopride in human plasma after oral administration of clebopride. Copyright 2010. Published by Elsevier B.V.

  10. A validated stability-indicating LC method for the separation of enantiomer and potential impurities of Linezolid using polar organic mode

    Directory of Open Access Journals (Sweden)

    T. Satyanarayana Raju

    2012-08-01

    Full Text Available Although a number of methods are available for evaluating Linezolid and its possible impurities, a common method for separation if its potential impurities, degradants and enantiomer in a single method with good efficiency remain unavailable. With the objective of developing an advanced method with shorter runtimes, a simple, precise, accurate stability-indicating LC method was developed for the determination of purity of Linezolid drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. This method is capable of separating all the related substances of Linezolid along with the chiral impurity. This method can also be used for the estimation of assay of Linezolid in drug substance as well as in drug product. The method was developed using Chiralpak IA (250 mm×4.6 mm, 5 μm column. A mixture of acetonitrile, ethanol, n-butyl amine and trifluoro acetic acid in 96:4:0.10:0.16 (v/v/v/v ratio was used as a mobile phase. The eluted compounds were monitored at 254 nm. Linezolid was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization (ICH guidelines with respect to specificity, limit of detection, limit of quantification, precision, linearity, accuracy, robustness and system suitability. Keywords: HPLC, Linezolid, Validation, Polar organic mode, Stability-indicating

  11. LC-MS (/MS) in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Hochstrasser, Denis; Fathi, Marc

    2012-01-01

    Toxicological screening is the analysis of biological samples to detect and identify unknown compounds. The high selectivity and sensitivity of liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) technology provide an attractive alternative to the current methods (LC-UV, GC/MS, etc.). For these reasons, an increasing number of applications are being published. This paper is a brief overview of LC-MS(/MS) screening methods developed for clinical toxicology in recent years. Various sample treatments, chromatographic separations and detection by mass spectrometry can be combined to obtain screening methods adapted to the constraints and needs of clinical toxicology laboratories. Currently the techniques are in the hands of specialists, mainly in academic institutions. However, the evolution in technology should allow application of these techniques as a tool in toxicology laboratories, thus allowing a more widespread exploitation of their potential.

  12. Development and Validation of a LC/MS/MS Method for the Determination of Duloxetine in Human Plasma and Its Application to Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    D. Chandrapal Reddy

    2012-01-01

    Full Text Available A selective, high sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS method has been developed and validated for the chromatographic separation and quantitation of duloxetine in human EDTA plasma using fluoxetine (IS as an internal standard. Analyte and IS were extracted from human plasma by liquid-liquid extraction using MTBE-n Hexane (80:20.The eluted samples were chromatographed on X-terra RP8 (50 mmx4.6 mm, 5 μm particle size column by using mixture of 30 mM ammonium formate (pH-5.0±0.05 and acetonitrile as an isocratic mobile phase at a flow rate of 0.40 mL/min and analyzed by mass spectrometer in the multiple reaction monitoring (MRM using the respective m/z 298.08→154.0 for duloxetine and 310.02→148.07 for IS. The linearity of the response/ concentration curve was established in human plasma over the concentration range 0.100-100.017 ng/mL. The lower detection limit (LOD,S/N>3 was 0.04 ng/mL and the lower limit of quantization (LOQ,S/N>10 was 0.100 ng/mL. This LC-MS/MS method was validated with Intra-batch and Inter-batch precision of 5.21-7.02. The Intra-batch and Inter-batch accuracy was 97.14-103.50 respectively. Recovery of duloxetine in human plasma is 80.31% and ISTD recovery is 81.09%. The main pharmacokinetic parameters were Tmax (hr = (7.25±1.581, Cmax (ng/mL (44.594±18.599, AUC0→t, = (984.702±526.502 and AUC0→∞, (1027.147±572.790 respectively.

  13. Identification and quantification of flavonoids and ellagic acid derivatives in therapeutically important Drosera species by LC-DAD, LC-NMR, NMR, and LC-MS.

    Science.gov (United States)

    Zehl, Martin; Braunberger, Christina; Conrad, Jürgen; Crnogorac, Marija; Krasteva, Stanimira; Vogler, Bernhard; Beifuss, Uwe; Krenn, Liselotte

    2011-06-01

    Droserae herba is a drug commonly used for treatment of convulsive or whooping cough since the seventeenth century. Because of the contribution of flavonoids and ellagic acid derivatives to the therapeutic activity of Droserae herba, an LC-DAD method has been developed for quantification of these analytes in four Drosera species used in medicine (Drosera anglica, D. intermedia, D. madagascariensis, and D. rotundifolia). During elaboration of the method 13 compounds, including three substances not previously described for Drosera species, were detected and unambiguously identified by means of extensive LC-MS and LC-NMR experiments and by off-line heteronuclear 2D NMR after targeted isolation. The most prominent component of D. rotundifolia and D. anglica, 2″-O-galloylhyperoside, with myricetin-3-O-β-glucopyranoside and kaempferol-3-O-(2″-O-galloyl)-β-galactopyranoside, were identified for the very first time in this genus. The LC-DAD method for quantification was thoroughly validated, and enables, for the first time, separation and precise analysis of these analytes in Droserae herba. Simple sample preparation and use of a narrow-bore column guarantee low cost and simplicity of the suggested system, which is excellently suited to quality control of the drug or herbal medicinal products containing this drug.

  14. A validated multianalyte LC-MS/MS method for quantification of 25 mycotoxins in cassava flour, peanut cake and maize samples.

    Science.gov (United States)

    Ediage, Emmanuel Njumbe; Di Mavungu, José Diana; Monbaliu, Sofie; Van Peteghem, Carlos; De Saeger, Sarah

    2011-05-25

    This study was designed to develop a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous detection and quantification of 25 mycotoxins in cassava flour, peanut cake and maize samples with particular focus on the optimization of the sample preparation protocol and method validation. All 25 mycotoxins were extracted in a single step with a mixture of methanol/ethyl acetate/water (70:20:10, v/v/v). The method limits of quantification (LOQ) varied from 0.3 μg/kg to 106 μg/kg. Good precision and linearity were observed for most of the mycotoxins. The method was applied for the analysis of naturally contaminated peanut cake, cassava flour and maize samples from the Republic of Benin. All samples analyzed (fifteen peanut cakes, four maize flour and four cassava flour samples) tested positive for one or more mycotoxins. Aflatoxins (total aflatoxins; 10-346 μg/kg) and ochratoxin A (cake samples while fumonisin B(1) (4-21 μg/kg), aflatoxin B(2) (flour samples. Fumonisin B(1) (13-836 μg/kg), fumonisin B(2) (5-221 μg/kg), fumonisin B(3) (

  15. Validation of a method for the determination of zolpidem in human plasma using LC with fluorescence detection.

    Science.gov (United States)

    Ring, P R; Bostick, J M

    2000-04-01

    A sensitive and selective high-performance liquid chromatography (HPLC) method was developed for the determination of zolpidem in human plasma. Zolpidem and the internal standard (trazodone) were extracted from human plasma that had been made basic. The basic sample was loaded onto a conditioned Bond Elut C18 cartridge, rinsed with water and eluted with methanol. Forty microliters were then injected onto the LC system. Separation was achieved on a C18 column (150 x 4.6 mm, 5 microm) with a mobile phase composed of acetonitrile:50 mM potassium phosphate monobasic at pH 6.0 (4:6, v/v). Detection was by fluorescence, with excitation at 254 nm and emission at 400 nm. The retention times of zolpidem and internal standard were approximately 4.7 and 5.3 min, respectively. The LC run time was 8 min. The assay was linear in concentration range 1-400 ng/ml for zolpidem in human plasma. The analysis of quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated excellent precision with relative standard deviations (RSD) of 3.7, 4.6, and 3.0%, respectively (n = 18). The method was accurate with all intraday (n = 6) and overall (n = 18) mean concentrations within 5.8% from nominal at all quality control sample concentrations. This method was also performed using a Gilson Aspec XL automated sample processor and autoinjector. The samples were manually fortified with internal standard and made basic. The aspec then performed the solid phase extraction and made injections of the samples onto the LC system. Using the automated procedure for analysis, quality control samples for zolpidem (3, 30, and 300 ng/ml) demonstrated acceptable precision with RSD values of 9.0, 4.9, and 5.1%, respectively (n = 12). The method was accurate with all intracurve (n = 4) and overall (n = 12) mean values being less than 10.8% from nominal at all quality control sample concentrations.

  16. A Simple and Direct LC-MS Method for Determination of Genotoxic Impurity Hydroxylamine in Pharmaceutical compounds.

    Science.gov (United States)

    Kumar, Thangarathinam; Ramya, Mohandass; Srinivasan, Viswanathan; Xavier, N

    2017-08-01

    Hydroxylamine is a known genotoxic impurity compound that needs to be controlled down to ppm level in pharmaceutical processes. It is difficult to detect using conventional analytical techniques due to its physio-chemical properties like lack of chromophore, low molecular weight, absence of carbon atom and high polarity. In addition to that, analysis of the pharmaceutical samples encounters considerable obstruction from matrix components that greatly overshadow the response of hydroxylamine. This study describes a simple, sensitive and direct Liquid Chromatographic-Mass Spectrometric method (LC-MS) for detection of hydroxylamine in pharmaceutical compounds. The LC-MS method was detected up to 0.008 ppm of hydroxylamine with S/N > 3.0 and quantified up to 0.025 ppm of hydroxylamine with S/N ratio >10.0. This validated method can be applied as a generic method to detect the hydroxylamine for pharmaceutical process control and drug substance release. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS.

    Science.gov (United States)

    Joshi, Payal; Bhoir, Suvarna; Bhagwat, A M; Vishwanath, K; Jadhav, R K

    2011-05-01

    Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itopride degraded in acid, alkali and oxidative stress conditions. The stability indicating method was developed and validated. The degradation pathway of the drug to products II-VIII is proposed.

  18. Development and Validation of RP-LC Method for the Determination of Cinnarizine/Piracetam and Cinnarizine/Heptaminol Acefyllinate in Presence of Cinnarizine Reported Degradation Products

    Directory of Open Access Journals (Sweden)

    Ola M. EL-Houssini

    2013-01-01

    Full Text Available Specific stability indicating reverse-phase liquid chromatography (RP-LC assay method (SIAM was developed for the determination of cinnarizine (Cinn/piracetam (Pira and cinnarizine (Cinn/heptaminol acefyllinate (Hept in the presence of the reported degradation products of Cinn. A C 18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20-200, 20-1000 and 25-1000 μgmL −1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations.

  19. Development and Validation of RP-LC Method for the Determination of Cinnarizine/Piracetam and Cinnarizine/Heptaminol Acefyllinate in Presence of Cinnarizine Reported Degradation Products

    Science.gov (United States)

    EL-Houssini, Ola M.; Zawilla, Nagwan H.; Mohammad, Mohammad A.

    2013-01-01

    Specific stability indicating reverse-phase liquid chromatography (RP-LC) assay method (SIAM) was developed for the determination of cinnarizine (Cinn)/piracetam (Pira) and cinnarizine (Cinn)/heptaminol acefyllinate (Hept) in the presence of the reported degradation products of Cinn. A C18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20–200, 20–1000 and 25–1000 μgmL−1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations. PMID:24137049

  20. A validated stability-indicating LC method for the separation of enantiomer and potential impurities of Linezolid using polar organic mode.

    Science.gov (United States)

    Satyanarayana Raju, T; Vishweshwari Kutty, O; Ganesh, V; Yadagiri Swamy, P

    2012-08-01

    Although a number of methods are available for evaluating Linezolid and its possible impurities, a common method for separation if its potential impurities, degradants and enantiomer in a single method with good efficiency remain unavailable. With the objective of developing an advanced method with shorter runtimes, a simple, precise, accurate stability-indicating LC method was developed for the determination of purity of Linezolid drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. This method is capable of separating all the related substances of Linezolid along with the chiral impurity. This method can also be used for the estimation of assay of Linezolid in drug substance as well as in drug product. The method was developed using Chiralpak IA (250 mm×4.6 mm, 5 μm) column. A mixture of acetonitrile, ethanol, n-butyl amine and trifluoro acetic acid in 96:4:0.10:0.16 (v/v/v/v) ratio was used as a mobile phase. The eluted compounds were monitored at 254 nm. Linezolid was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization (ICH) guidelines with respect to specificity, limit of detection, limit of quantification, precision, linearity, accuracy, robustness and system suitability.

  1. Analytical method for the determination of cyromazine and melamine residues in soil using LC-UV and GC-MSD.

    Science.gov (United States)

    Yokley, R A; Mayer, L C; Rezaaiyan, R; Manuli, M E; Cheung, M W

    2000-08-01

    A method is reported for the determination of cyromazine and melamine residues in soil. Soil samples are extracted twice via mechanical shaking, each time with 70% acetonitrile/30% 0.050 M ammomium carbonate for 30 min. An aliquot portion of the pooled extracts is subjected to strong cation exchange (SCX) purification on AG 50W-X4 resin. Final analysis is accomplished using liquid chromatography-ultraviolet (LC-UV) detection at a wavelength of 214 nm. Confirmatory analyses can be performed using gas chromatography-mass selective detection (GC-MSD) in the selected ion monitoring (SIM) mode. The limit of detection (LOD) is 2.5 ng injected and the limit of quantification (LOQ) is 10 ppb when using LC-UV for the analysis of N-cyclopropyl-1,3,5-triazine-2,4, 6-triamine (cyromazine) and 1,3,5-triazine-2,4,6-triamine (melamine). The LOD is 0.050 ng injected and the LOQ is 10 ppb when using GC-MSD for confirmatory analyses. The mean procedural recoveries were 97 and 95% and the standard deviations were 16 and 11% for cyromazine and melamine, respectively (n = 24), when using LC-UV. The mean procedural recoveries were 107 and 92% and the standard deviations were 9.9 and 16% for cyromazine and melamine, respectively (n = 29), when using GC-MSD. The method validation study was conducted under U.S. EPA FIFRA Good Laboratory Practice Guidelines 40 CFR 160. The method also passed an Independent Laboratory Validation (ILV) as per U.S. EPA FIFRA Subdivision N.

  2. LC-NMR, NMR, and LC-MS identification and LC-DAD quantification of flavonoids and ellagic acid derivatives in Drosera peltata.

    Science.gov (United States)

    Braunberger, Christina; Zehl, Martin; Conrad, Jürgen; Fischer, Sonja; Adhami, Hamid-Reza; Beifuss, Uwe; Krenn, Liselotte

    2013-08-01

    The herb of Drosera peltata, commonly named the shield sundew, is used as an antitussive in phytotherapy, although the plants' composition has not been determined in detail so far. Hence, in this study, we present a validated, sensitive, reliable, and cheap narrow-bore LC-DAD method for the simultaneous quantification of flavonoids and ellagic acid derivatives in this herbal drug. In addition, the structures of 13 compounds have been elucidated by LC-MS, LC-NMR, and offline NMR experiments after isolation: herbacetin-3-O-glucoside (1), gossypitrin (2), ellagic acid (3), quercetin-7-O-glucoside (4), isoquercitrin (5), kaempferol-3-O-(6″-O-galloyl)-glucoside (6), herbacetin-7-O-glucoside (7), astragalin (8), gossypetin (9), herbacetin (10), quercetin (11), 3,3'-di-O-methyl ellagic acid (12), and kaempferol (13). Compounds 1, 2, 4, 5, 6, 7, and 10 have been identified in D. peltata for the first time, and compounds 1, 4, 6, 7, and 10 have not been detected in any Drosera species before. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Influence of modulation method on using LC-traps with single-phase voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Min, Huang; Bai, Haofeng

    2015-01-01

    The switching-frequency LC-trap filter has recently been employed with high-order passive filters for Voltage Source Inverters (VSIs). This paper investigates the influence of modulation method on using the LC-traps with single-phase VSIs. Two-level (bipolar) and three-level (unipolar) modulations...... that include phase distortion and alternative phase opposition distortion methods are analyzed. Harmonic filtering performances of four LC-trap-based filters with different locations of LC-traps are compared. It is shown that the use of parallel-LC-traps in series with filter inductors, either grid...... or converter side, has a worse harmonic filtering performance than using series-LC-trap in the shunt branch. Simulations and experimental results are presented for verifications....

  4. Determination of the appetite suppressant P57 in Hoodia gordonii plant extracts and dietary supplements by liquid chromatography/electrospray ionization mass spectrometry (LC-MSD-TOF) and LC-UV methods.

    Science.gov (United States)

    Avula, Bharathi; Wang, Yan-Hong; Pawar, Rahul S; Shukla, Yatin J; Schaneberg, Brian; Khan, Ikhlas A

    2006-01-01

    Hoodia gordonii is traditionally used in South Africa for its appetite suppressant properties. P57AS3 (P57), an oxypregnane steroidal glycoside, is the only reported active constituent from this plant as an appetite suppressant. Effective quality control of these extracts or products requires rapid methods to determine P57 content. New methods of liquid chromatography/mass spectrometry (LC/MS) and LC-UV for analysis of P57 from H. gordonii have been developed. The quantitative determination of P57 was achieved with a Phenomenex Gemini (Torrance, CA) reversed-phase column using gradient mobile phase of water and acetonitrile, both containing 0.1% acetic acid. The method was validated for linearity, repeatability, and limits of detection and quantification. Good results were obtained in terms of repeatability (relative standard deviation <5.0%) and recovery (98.5-103.5%). The developed methods were applied to the determination of P57 for H. gordonii plant samples, one related genus (Opuntia ficus-indica), and dietary supplements that claim to contain H. gordonii.

  5. Development and validation of an improved method for the quantitation of sertraline in human plasma using LC-MS-MS and its application to bioequivalence studies.

    Science.gov (United States)

    Zhang, Mengliang; Gao, Feng; Cui, Xiangyong; Zhang, Yunhui; Sun, Yantong; Gu, Jingkai

    2011-02-01

    A rapid and sensitive LC-MS-MS method for the quantitation of sertraline in human plasma was developed and validated. Sertraline and the internal standard, telmisartan, were cleaned up by protein precipitation from 100 μL of plasma sample, and analyzed on a TC-C18 column (5 μm, 150 × 4.6 mm i.d.) using 70% acetonitrile and 30% 10 mM ammonium acetate (0.1% formic acid) as mobile phase. The method was demonstrated to be linear from 0.1 ng/mL to 50 ng/mL with the lower limit of quantitation of 0.1 ng/mL. Intra- and inter-day precision were below 4.40% and 3.55%. Recoveries of sertraline at low, medium, and high levels were 88.0 ± 2.3%, 88.2 ± 1.9%, and 90.0 ± 2.0%, respectively. The method was successfully applied to a bioequivalence study of sertraline after a single oral administration of 50 mg sertraline hydrochloride tablets.

  6. Relationship between plasma and salivary melatonin and cortisol investigated by LC-MS/MS.

    Science.gov (United States)

    van Faassen, Martijn; Bischoff, Rainer; Kema, Ido P

    2017-08-28

    Disturbance of the circadian rhythm has been associated with disease states, such as metabolic disorders, depression and cancer. Quantification of the circadian markers such as melatonin and cortisol critically depend on reliable and reproducible analytical methods. Previously, melatonin and cortisol were primarily analyzed separately, mainly using immunoassays. Here we describe the validation and application of a high-throughput liquid chromatography in combination with mass spectrometry (LC-MS/MS) method for the combined analysis of melatonin and cortisol in plasma and saliva. The LC-MS/MS method was validated according to international validation guidelines. We used this method to analyze total plasma, free plasma (as obtained by equilibrium dialysis) and saliva melatonin and cortisol in healthy adults. Validation results for plasma and saliva melatonin and cortisol were well within the international validation criteria. We observed no difference between saliva collected by passive drooling or Salivette. Moreover, we noted a significant difference in saliva vs. free plasma melatonin. We observed on average 36% (95% CI: 4%-60%) higher salivary melatonin levels in comparison to free plasma melatonin, suggestive of local production of melatonin in the salivary glands. The novel outcome of this study is probably due to the high precision of our LC-MS/MS assay. These outcomes illustrate the added value of accurate and sensitive mass spectrometry based methods for the quantification of neuroendocrine biomarkers.

  7. Development and validation of a highly sensitive LC-ESI-MS/MS method for estimation of IIIM-MCD-211, a novel nitrofuranyl methyl piperazine derivative with potential activity against tuberculosis: Application to drug development.

    Science.gov (United States)

    Magotra, Asmita; Sharma, Anjna; Gupta, Ajai Prakash; Wazir, Priya; Sharma, Shweta; Singh, Parvinder Pal; Tikoo, Manoj Kumar; Vishwakarma, Ram A; Singh, Gurdarshan; Nandi, Utpal

    2017-08-15

    In the present study, a simple, sensitive, specific and rapid liquid chromatography (LC) tandem mass spectrometry (MS/MS) method was developed and validated according to the Food and Drug Administration (FDA) guidelines for estimation of IIIM-MCD-211 (a potent oral candidate with promising action against tuberculosis) in mice plasma using carbamazepine as internal standard (IS). Bioanalytical method consisted of one step protein precipitation for sample preparation followed by quantitation in LC-MS/MS using positive electrospray ionization technique (ESI) operating in multiple reaction monitoring (MRM) mode. Elution was achieved in gradient mode on High Resolution Chromolith RP-18e column with mobile phase comprised of acetonitrile and 0.1% (v/v) formic acid in water at the flow rate of 0.4mL/min. Precursor to product ion transitions (m/z 344.5/218.4 and m/z 237.3/194.2) were used to measure analyte and IS, respectively. All validation parameters were well within the limit of acceptance criteria. The method was successfully applied to assess the pharmacokinetics of the candidate in mice following oral (10mg/kg) and intravenous (IV; 2.5mg/kg) administration. It was also effectively used to quantitate metabolic stability of the compound in mouse liver microsomes (MLM) and human liver microsomes (HLM) followed by its in-vitro-in-vivo extrapolation. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Development and validation of a novel LC non-derivatization method for the determination of amikacin in pharmaceuticals based on evaporative light scattering detection.

    Science.gov (United States)

    Galanakis, Evagelia G; Megoulas, Nikolaos C; Solich, Petr; Koupparis, Michael A

    2006-03-18

    A novel method for the direct determination of the aminoglycoside antibiotic amikacin and its precursor component kanamycin was developed and validated, based on reversed phase LC with evaporative light scattering detector (ELSD). ELSD response to amikacin was found to be enhanced by: (a) use of ion-pairing acidic reagents of increased molecular mass, (b) increase of mobile phase volatility and (c) decrease of peak width and asymmetry (obtained by controlling the mobile phase acidity and/or ratio of organic solvent to water). Utilizing a Thermo Hypersil BetaBasic C(18) column, the selected optimized mobile phase was water-methanol (60:40, v/v), containing 3.0 mll(-1) nonafluoropentanoic acid (18.2mM) (isocratic elution with flow rate of 1.0 mlmin(-1)). ELSD experimental parameters were: nitrogen pressure 3.5 bar, evaporation temperature 50 degrees C, and gain 11. Amikacin was eluted at 8.6 min and kanamycin at 10.4 min with a resolution of 1.5. Logarithmic calibration curves were obtained from 7 to 77 microgml(-1) (r>0.9995) for amikacin and 8 to 105 microgml(-1) (r>0.998) for kanamycin, with a LOD equal to 2.2 and 2.5 microgml(-1), respectively. In amikacin sulfate pharmaceutical raw materials, the simultaneous determination of sulfate (t(R)=2.3 min, LOD=1.8 microgml(-1), range 5-40 microgml(-1), %R.S.D.=1.1, r>0.9997), kanamycin and amikacin was feasible. No significant difference was found between the results of the developed LC-ELSD method and those of reference methods, while the mean recovery of kanamycin from spiked samples (0.5%, w/w) was 97.3% (%R.S.D.method was applied for the determination of amikacin in pharmaceutical formulations (injection solutions) without any interference from the matrix (recovery from spiked samples ranged from 95.6 to 103.8%).

  9. Resonance Damping and Parameter Design Method for LCL-LC Filter Interfaced Grid-Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Li, Zipeng; Jiang, Aiting; Shen, Pan

    2016-01-01

    , this paper presents a systematic design method for the LCL-LC filtered grid-connected photovoltaic (PV) system. With this method, controller parameters and the active damping feedback coefficient are easily obtained by specifying the system stability and dynamic performance indices, and it is more convenient......-frequency harmonics attenuation ability, but the resonant problem affects the system stability remarkably. In this paper, active damping based on the capacitor voltage feedback is proposed using the concept of the equivalent virtual impedance in parallel with the capacitor. With the consideration of system delay...... to optimize the system performance according to the predefined satisfactory region. Finally, the simulation results are presented to validate the proposed design method and control scheme....

  10. Two simple cleanup methods combined with LC-MS/MS for quantification of steroid hormones in in vivo and in vitro assays

    DEFF Research Database (Denmark)

    Weisser, Johan Juhl; Hansen, Cecilie Hurup; Poulsen, Rikke

    2016-01-01

    Measuring both progestagens, androgens, corticosteroids as well as estrogens with a single method makes it possible to investigate the effects of endocrine-disrupting chemicals (EDCs) on the main pathways in the mammalian steroidogenesis. This paper presents two simple methods for the determination...... of the major steroid hormones in biological matrixes using liquid chromatography tandem mass spectrometry (LC-MS(2)). A novel method was developed for the determination of 14 steroids in the H295R in vitro assay without the need for solid phase extraction (SPE) purification prior to LC-MS(2) analysis....... The in vitro assay was validated by exposing H295R cells to prochloraz for inhibiting steroid hormone secretion and by exposing cells to forskolin for inducing steroid hormone secretion. The developed method fulfills the recommendations for the H295R assay suggested by the OECD. Furthermore, a simple off...

  11. HPLC and LC-MS/MS methods for determination of sodium benzoate and potassium sorbate in food and beverages: performances of local accredited laboratories via proficiency tests in Turkey.

    Science.gov (United States)

    Gören, Ahmet C; Bilsel, Gökhan; Şimşek, Adnan; Bilsel, Mine; Akçadağ, Fatma; Topal, Kevser; Ozgen, Hasan

    2015-05-15

    High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. LC-ESI/MS/MS method for rapid screening and confirmation of 44 exogenous anabolic steroids in human urine.

    Science.gov (United States)

    Jeon, Byoung Wook; Yoo, Hye Hyun; Jeong, Eun Sook; Kim, Ho Jun; Jin, Changbae; Kim, Dong Hyun; Lee, Jaeick

    2011-09-01

    A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers.

  13. Targeted LC-MS/MS method for quantification of Plant Lignans and Enterolignans in Biofluids from Humans and Pigs

    DEFF Research Database (Denmark)

    Nørskov, Natalja; Olsen, Anja; Tjønneland, Anne

    2015-01-01

    Lignans have gained nutritional interest due to their promising role in the prevention of lifestyle diseases. However, epidemiological studies are in need of more evidence to link the intake of lignans to this promising role. In this context, it is necessary to study large population groups...... to obtain sufficient statistical power. Therefore, there is a demand for fast, sensitive, and accurate methods for quantitation with high throughput of samples. This paper presents a validated LC-MS/MS method for the quantitation of eight plant lignans (matairesinol, hydroxymatairesinol...

  14. Multi-residue analysis method for analysis of pharmaceuticals using liquid chromatography-time of flight/mass spectrometry (LC-TOF/MS) in water sample

    Science.gov (United States)

    Al-Qaim, Fouad Fadhil; Abdullah, Md Pauzi; Othman, Mohamed Rozali

    2013-11-01

    In this work, a developed method using solid - phase extraction (SPE) followed by liquid chromatography - time of flight mass spectrometry (LC-ESI-TOF/MS) was developed and validated for quantification and confirmation of eleven pharmaceuticals with different therapeutic classes in water samples, Malaysia. These compounds are caffeine (CAF), prazosin (PRZ), enalapril (ENL), carbamazepine (CBZ), nifedipine (NFD), levonorgestrel (LNG), simvastatin (SMV), hydrochlorothiazide (HYD), gliclazide (GLIC), diclofenac-Na (DIC-Na) and mefenamic acid (MEF). LC was performed on a Dionex Ultimate 3000/LC 09115047 (USA) system. Chromatography was performed on a Thermo Scientific C18 (250 mm × 2.1 mm, i.d.: 5μm) column. Several parameters were optimised such as; mobile phase, gradient elution, collision energy and solvent elution for extraction of compounds from water. The recoveries obtained ranged from 30-148 % in river water. Five pharmaceutical compounds were detected in the surface water samples: caffeine, prazosin, enalpril, diclofenac-Na and mefenamic acid. The developed method is precise and accepted recoveries were got. In addition, this method is suitable to identify and quantify trace concentrations of pharmaceuticals in surface water.

  15. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  16. L-C Measurement Acquisition Method for Aerospace Systems

    Science.gov (United States)

    Woodard, Stanley E.; Taylor, B. Douglas; Shams, Qamar A.; Fox, Robert L.

    2003-01-01

    This paper describes a measurement acquisition method for aerospace systems that eliminates the need for sensors to have physical connection to a power source (i.e., no lead wires) or to data acquisition equipment. Furthermore, the method does not require the sensors to be in proximity to any form of acquisition hardware. Multiple sensors can be interrogated using this method. The sensors consist of a capacitor, C(p), whose capacitance changes with changes to a physical property, p, electrically connected to an inductor, L. The method uses an antenna to broadcast electromagnetic energy that electrically excites one or more inductive-capacitive sensors via Faraday induction. This method facilitates measurements that were not previously possible because there was no practical means of providing power and data acquisition electrical connections to a sensor. Unlike traditional sensors, which measure only a single physical property, the manner in which the sensing element is interrogated simultaneously allows measurement of at least two unrelated physical properties (e.g., displacement rate and fluid level) by using each constituent of the L-C element. The key to using the method for aerospace applications is to increase the distance between the L-C elements and interrogating antenna; develop all key components to be non-obtrusive and to develop sensing elements that can easily be implemented. Techniques that have resulted in increased distance between antenna and sensor will be presented. Fluid-level measurements and pressure measurements using the acquisition method are demonstrated in the paper.

  17. Development of LC-MS determination method and back-propagation ANN pharmacokinetic model of corynoxeine in rat.

    Science.gov (United States)

    Ma, Jianshe; Cai, Jinzhang; Lin, Guanyang; Chen, Huilin; Wang, Xianqin; Wang, Xianchuan; Hu, Lufeng

    2014-05-15

    Corynoxeine(CX), isolated from the extract of Uncaria rhynchophylla, is a useful and prospective compound in the prevention and treatment for vascular diseases. A simple and selective liquid chromatography mass spectrometry (LC-MS) method was developed to determine the concentration of CX in rat plasma. The chromatographic separation was achieved on a Zorbax SB-C18 (2.1 mm × 150 mm, 5 μm) column with acetonitrile-0.1% formic acid in water as mobile phase. Selective ion monitoring (SIM) mode was used for quantification using target ions m/z 383 for CX and m/z 237 for the carbamazepine (IS). After the LC-MS method was validated, it was applied to a back-propagation artificial neural network (BP-ANN) pharmacokinetic model study of CX in rats. The results showed that after intravenous administration of CX, it was mainly distributed in blood and eliminated quickly, t1/2 was less than 1h. The predicted concentrations generated by BP-ANN model had a high correlation coefficient (R>0.99) with experimental values. The developed BP-ANN pharmacokinetic model can be used to predict the concentration of CX in rats. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. High throughput LC-MS/MS method for the simultaneous analysis of multiple vitamin D analytes in serum.

    Science.gov (United States)

    Jenkinson, Carl; Taylor, Angela E; Hassan-Smith, Zaki K; Adams, John S; Stewart, Paul M; Hewison, Martin; Keevil, Brian G

    2016-03-01

    Recent studies suggest that vitamin D-deficiency is linked to increased risk of common human health problems. To define vitamin D 'status' most routine analytical methods quantify one particular vitamin D metabolite, 25-hydroxyvitamin D3 (25OHD3). However, vitamin D is characterized by complex metabolic pathways, and simultaneous measurement of multiple vitamin D metabolites may provide a more accurate interpretation of vitamin D status. To address this we developed a high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyse multiple vitamin D analytes, with particular emphasis on the separation of epimer metabolites. A supportive liquid-liquid extraction (SLE) and LC-MS/MS method was developed to quantify 10 vitamin D metabolites as well as separation of an interfering 7α-hydroxy-4-cholesten-3-one (7αC4) isobar (precursor of bile acid), and validated by analysis of human serum samples. In a cohort of 116 healthy subjects, circulating concentrations of 25-hydroxyvitamin D3 (25OHD3), 3-epi-25-hydroxyvitamin D3 (3-epi-25OHD3), 24,25-dihydroxyvitamin D3 (24R,25(OH)2D3), 1,25-dihydroxyvitamin D3 (1α,25(OH)2D3), and 25-hydroxyvitamin D2 (25OHD2) were quantifiable using 220μL of serum, with 25OHD3 and 24R,25(OH)2D3 showing significant seasonal variations. This high-throughput LC-MS/MS method provides a novel strategy for assessing the impact of vitamin D on human health and disease. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Development of an LC/MS/MS method in order to determine arctigenin in rat plasma: its application to a pharmacokinetic study.

    Science.gov (United States)

    Zou, Quanfei; Gu, Yuan; Lu, Rong; Zhang, Tiejun; Zhao, Guang-Rong; Liu, Changxiao; Si, Duanyun

    2013-09-01

    In this study, a simple and sensitive LC/MS/MS method was developed and validated for the determination of arctigenin in rat plasma. The MS detection was performed using multiple reaction monitoring at the transitions of m/z 373.2 → 137.3 for arctigenin and m/z 187.1 → 131.0 for psoralen (internal standard) with a Turbo IonSpray electrospray in positive mode. The calibration curves fitted a good linear relationship over the concentration range of 0.2-500 ng/mL. It was found that arctigenin is not stable enough at both room temperature and -80 °C unless mixed with methanol before storage. The validated LC/MS/MS method was successfully applied for the pharmacokinetic study of arctigenin in rats. After intravenous injection of 0.3 mg/kg arctigenin injection to rats, the maximum concentration, half-life and area under the concentration-time curve were 323 ± 65.2 ng/mL, 0.830 ± 0.166 and 81.0 ± 22.1 h ng/mL, respectively. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Improved methods for urinary atrazine mercapturate analysis-Assessment of an enzyme-linked immunosorbent assay (ELISA) and a novel liquid chromatography-mass spectrometry (LC-MS) method utilizing online solid phase extraction (SPE)

    International Nuclear Information System (INIS)

    Koivunen, Marja E.; Dettmer, Katja; Vermeulen, Roel; Bakke, Berit; Gee, Shirley J.; Hammock, Bruce D.

    2006-01-01

    Elimination of interfering substances in urine by solid phase extraction (SPE) prior to analysis resulted in 10-fold improvement in the sensitivity of atrazine mercapturate (AM) enzyme-linked immunosorbent assay (ELISA) compared to previous reports. Of the two tested SPE systems, Oasis[reg] HLB and MCX, the mixed-mode MCX gave good recoveries (82%) of AM in spiked samples measured by ELISA, whereas the reverse-phase HLB phase was not compatible with the immunochemical method. At relatively high concentrations of urinary AM (>20 ng mL -1 ), sample dilution was effective enough for the elimination of interfering substances. The new liquid chromatography-mass spectrometry (LC-MS) method developed for AM utilizes online-SPE with Oasis[reg] HLB, column switching and a stable-isotope internal standard. The limit of quantification (0.05 ng mL -1 ) indicates improved sensitivity compared with most previously published LC-MS methods for AM. Validation of all three methods, LC-MS, ELISA + SPE and ELISA + dilution with spiked urine samples showed good correlation between the known and measured concentrations with R 2 values of 0.996, 0.957 and 0.961, respectively. When a set (n = 70 plus 12 blind duplicates) of urine samples from farmers exposed to atrazine was analyzed, there was a good agreement (R 2 = 0.917) between the log normalized data obtained by ELISA + SPE and LC-MS. High correlation among the data obtained by the two tested methods and the LC-MS method by the Center of Disease Control and Prevention (CDC), together with low variability among the blind duplicates, suggests that both methods reported here would be suitable for the analysis of urinary AM as a biomarker for human exposure of atrazine

  1. Development and validation of an LC-UV method for the determination of sulfonamides in animal feeds.

    Science.gov (United States)

    Kumar, P; Companyó, R

    2012-05-01

    A simple LC-UV method was developed for the determination of residues of eight sulfonamides (sulfachloropyridazine, sulfadiazine, sulfadimidine, sulfadoxine, sulfamethoxypyridazine, sulfaquinoxaline, sulfamethoxazole, and sulfadimethoxine) in six types of animal feed. C18, Oasis HLB, Plexa and Plexa PCX stationary phases were assessed for the clean-up step and the latter was chosen as it showed greater efficiency in the clean-up of interferences. Feed samples spiked with sulfonamides at 2 mg/kg were used to assess the trueness (recovery %) and precision of the method. Mean recovery values ranged from 47% to 66%, intra-day precision (RSD %) from 4% to 15% and inter-day precision (RSD %) from 7% to 18% in pig feed. Recoveries and intra-day precisions were also evaluated in rabbit, hen, cow, chicken and piglet feed matrices. Calibration curves with standards prepared in mobile phase and matrix-matched calibration curves were compared and the matrix effects were ascertained. The limits of detection and quantification in the feeds ranged from 74 to 265 µg/kg and from 265 to 868 µg/kg, respectively. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Identification, characterization and quantification of new impurities by LC-ESI/MS/MS and LC-UV methods in rivastigmine tartrate active pharmaceutical ingredient.

    Science.gov (United States)

    Thomas, Saji; Shandilya, Sanjeev; Bharati, Amber; Paul, Saroj Kumar; Agarwal, Ashutosh; Mathela, Chandra S

    2012-01-05

    Six impurities were detected at trace level in rivastigmine tartrate drug substance by a newly developed high performance liquid chromatography method. Three impurities were characterized rapidly and three impurities were found to be unknown. The unknown impurities were enriched and identified with a combination of semi-preparative HPLC and LC/MS/MS techniques. Proposed structures were further confirmed by characterization using NMR, FT-IR, and EA techniques of impurity standards. Based on the spectroscopic, spectrometric and elemental analysis data unknown impurities were characterized as 3-[1-(dimethylamino)ethyl]phenyl N-ethyl-N-methyl carbamate N-oxide, ethyl-methyl-carbamic acid 4-(1-dimethylamino-ethyl)-phenyl ester and ethyl-methyl-carbamic acid 2-(1-dimethylamino-ethyl)-phenyl ester. A plausible mechanism for the formation of these impurities is also proposed. The method was validated according to ICH guidelines for fourteen impurities to demonstrate specificity, precision, linearity, accuracy and stability indicating nature of the method. Regression analysis showed correlation coefficient value greater than 0.999 for rivastigmine tartrate and its impurities. Accuracy of the method was established based on the recovery obtained between 93.41 and 113.33% for all impurities. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Validation of the Mass-Extraction-Window for Quantitative Methods Using Liquid Chromatography High Resolution Mass Spectrometry.

    Science.gov (United States)

    Glauser, Gaétan; Grund, Baptiste; Gassner, Anne-Laure; Menin, Laure; Henry, Hugues; Bromirski, Maciej; Schütz, Frédéric; McMullen, Justin; Rochat, Bertrand

    2016-03-15

    A paradigm shift is underway in the field of quantitative liquid chromatography-mass spectrometry (LC-MS) analysis thanks to the arrival of recent high-resolution mass spectrometers (HRMS). The capability of HRMS to perform sensitive and reliable quantifications of a large variety of analytes in HR-full scan mode is showing that it is now realistic to perform quantitative and qualitative analysis with the same instrument. Moreover, HR-full scan acquisition offers a global view of sample extracts and allows retrospective investigations as virtually all ionized compounds are detected with a high sensitivity. In time, the versatility of HRMS together with the increasing need for relative quantification of hundreds of endogenous metabolites should promote a shift from triple-quadrupole MS to HRMS. However, a current "pitfall" in quantitative LC-HRMS analysis is the lack of HRMS-specific guidance for validated quantitative analyses. Indeed, false positive and false negative HRMS detections are rare, albeit possible, if inadequate parameters are used. Here, we investigated two key parameters for the validation of LC-HRMS quantitative analyses: the mass accuracy (MA) and the mass-extraction-window (MEW) that is used to construct the extracted-ion-chromatograms. We propose MA-parameters, graphs, and equations to calculate rational MEW width for the validation of quantitative LC-HRMS methods. MA measurements were performed on four different LC-HRMS platforms. Experimentally determined MEW values ranged between 5.6 and 16.5 ppm and depended on the HRMS platform, its working environment, the calibration procedure, and the analyte considered. The proposed procedure provides a fit-for-purpose MEW determination and prevents false detections.

  4. Evaluation of Normalization Methods to Pave the Way Towards Large-Scale LC-MS-Based Metabolomics Profiling Experiments

    Science.gov (United States)

    Valkenborg, Dirk; Baggerman, Geert; Vanaerschot, Manu; Witters, Erwin; Dujardin, Jean-Claude; Burzykowski, Tomasz; Berg, Maya

    2013-01-01

    Abstract Combining liquid chromatography-mass spectrometry (LC-MS)-based metabolomics experiments that were collected over a long period of time remains problematic due to systematic variability between LC-MS measurements. Until now, most normalization methods for LC-MS data are model-driven, based on internal standards or intermediate quality control runs, where an external model is extrapolated to the dataset of interest. In the first part of this article, we evaluate several existing data-driven normalization approaches on LC-MS metabolomics experiments, which do not require the use of internal standards. According to variability measures, each normalization method performs relatively well, showing that the use of any normalization method will greatly improve data-analysis originating from multiple experimental runs. In the second part, we apply cyclic-Loess normalization to a Leishmania sample. This normalization method allows the removal of systematic variability between two measurement blocks over time and maintains the differential metabolites. In conclusion, normalization allows for pooling datasets from different measurement blocks over time and increases the statistical power of the analysis, hence paving the way to increase the scale of LC-MS metabolomics experiments. From our investigation, we recommend data-driven normalization methods over model-driven normalization methods, if only a few internal standards were used. Moreover, data-driven normalization methods are the best option to normalize datasets from untargeted LC-MS experiments. PMID:23808607

  5. Rapid Screening of Acetylcholinesterase Inhibitors by Effect-Directed Analysis Using LC × LC Fractionation, a High Throughput in Vitro Assay, and Parallel Identification by Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Ouyang, Xiyu; Leonards, Pim E G; Tousova, Zuzana; Slobodnik, Jaroslav; de Boer, Jacob; Lamoree, Marja H

    2016-02-16

    Effect-directed analysis (EDA) is a useful tool to identify bioactive compounds in complex samples. However, identification in EDA is usually challenging, mainly due to limited separation power of the liquid chromatography based fractionation. In this study, comprehensive two-dimensional liquid chromatography (LC × LC) based microfractionation combined with parallel high resolution time of flight (HR-ToF) mass spectrometric detection and a high throughput acetylcholinesterase (AChE) assay was developed. The LC × LC fractionation method was validated using analytical standards and a C18 and pentafluorophenyl (PFP) stationary phase combination was selected for the two-dimensional separation and fractionation in four 96-well plates. The method was successfully applied to identify AChE inhibitors in a wastewater treatment plant (WWTP) effluent. Good orthogonality (>0.9) separation was achieved and three AChE inhibitors (tiapride, amisulpride, and lamotrigine), used as antipsychotic medicines, were identified and confirmed by two-dimensional retention alignment as well as their AChE inhibition activity.

  6. Processing methods for differential analysis of LC/MS profile data

    Directory of Open Access Journals (Sweden)

    Orešič Matej

    2005-07-01

    Full Text Available Abstract Background Liquid chromatography coupled to mass spectrometry (LC/MS has been widely used in proteomics and metabolomics research. In this context, the technology has been increasingly used for differential profiling, i.e. broad screening of biomolecular components across multiple samples in order to elucidate the observed phenotypes and discover biomarkers. One of the major challenges in this domain remains development of better solutions for processing of LC/MS data. Results We present a software package MZmine that enables differential LC/MS analysis of metabolomics data. This software is a toolbox containing methods for all data processing stages preceding differential analysis: spectral filtering, peak detection, alignment and normalization. Specifically, we developed and implemented a new recursive peak search algorithm and a secondary peak picking method for improving already aligned results, as well as a normalization tool that uses multiple internal standards. Visualization tools enable comparative viewing of data across multiple samples. Peak lists can be exported into other data analysis programs. The toolbox has already been utilized in a wide range of applications. We demonstrate its utility on an example of metabolic profiling of Catharanthus roseus cell cultures. Conclusion The software is freely available under the GNU General Public License and it can be obtained from the project web page at: http://mzmine.sourceforge.net/.

  7. Validation of an LC-MS/MS method for analysis of anti-diabetic drugs in botanical dietary supplements labeled for blood sugar management.

    Science.gov (United States)

    Ma, Jun; Pawar, Rahul S; Grundel, Erich

    2018-03-01

    We developed and validated a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to detect and quantitate 14 anti-diabetic, 2 anti-obesity, and 3 cholesterol-lowering drugs in botanical dietary supplements marketed for blood sugar management. Many botanical dietary supplements which carry label statements related to blood sugar management are available over the Internet. Potential adulteration of such dietary supplements with anti-diabetic and other prescription drugs, some of which have been removed from the market due to adverse events, is of concern. No significant matrix effects were observed and mean recoveries of all 19 analytes from a single product matrix were 88 to 113% at spiking concentrations from 500 to 2000 μg/g. Mean recoveries of metformin, phenformin, and sibutramine from matrices prepared from multiple product composites ranged from 93 to 115% at a spiking concentration of 100 μg/g. The relative standard deviations (RSD) (%) of intra-day analyses ranged from 0.2 to 13 for all recovery studies. Eighty dietary supplements obtained in the USA and carrying label statements related to blood sugar management were analyzed using this method and none were found to be adulterated with the above 19 drugs. Two products obtained outside of the USA and known to be adulterated were also analyzed by this method and found to contain phenformin, glibenclamide, and sibutramine. This method provided satisfactory selectivity, linearity, accuracy, precision, and sensitivity for rapid determination of 19 drugs and has broad applicability for the analysis of dietary supplements for possible adulteration with these compounds. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  8. LC-MSMS assays of urinary cortisol, a comparison between four in-house assays.

    Science.gov (United States)

    Brossaud, Julie; Leban, Monique; Corcuff, Jean-Benoit; Boux de Casson, Florence; Leloupp, Anne-Gaëlle; Masson, Damien; Moal, Valérie; Bach-Ngohou, Kalyane

    2018-06-27

    Twenty-four hour urinary free cortisol (UFC) determination can be used for screening and follow-up of Cushing syndrome (CS). As immunoassay methods lack specificity for UFC measurement, the use of high-performance liquid chromatography coupled to mass spectrometer (LC-MSMS) is recommended. The aim of our study was to compare UFC results using four LC-MSMS methods performed in four independent laboratories in order to evaluate interlaboratory agreement. Frozen aliquots of 24-h urine samples (78 healthy volunteers and 20 patients with CS) were sent to four different laboratories for analysis. Following liquid-liquid or solid-liquid extraction, UFC were determined using four different LC-MSMS assay. UFC intra- and interassays variation coefficients were lower than 10% for each centre. External quality control results were not significantly different. UFC normal ranges (established from healthy volunteers) were 17-126, 15-134, 12-118 and 27-157 nmol/day, respectively. Classification of UFC from healthy volunteers and patients with CS using a 95th percentile threshold was similar. However, for extreme UFC values (270 nmol/day), negative or positive bias was noted. Even for highly specific methods such as LC-MSMS, variations of results can be found depending on analytical process. Validation of LC-MSMS methods including determination of the reference range is essential.

  9. Development and validation of LC-MS/MS method for the determination of Ochratoxin A and its metabolite Ochratoxin α in poultry tissues and eggs.

    Science.gov (United States)

    Paoloni, Angela; Solfrizzo, Michele; Bibi, Rita; Pecorelli, Ivan

    2018-05-04

    The objective of this study was to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of Ochratoxin A (OTA) and Ochratoxin α (OTα) in poultry tissues and eggs. The two toxins were extracted by a mixture of acetonitrile/water, purified with a reversed phase C18 solid phase extraction column (SPE) and determined by LC-MS/MS. The LC-MS/MS method performances were evaluated in terms of linearity in solvent and in matrix (ranged from 0.5 to 15.10 µg L -1 for OTA and from 0.60 to 17.85 µg L -1 for OTα), limit of detection (LOD), limit of quantitation (LOQ), specificity, accuracy and precision in repeatability conditions. Recovery experiments were performed by spiking poultry liver, kidney, muscle and eggs around 1 µg kg -1 and 10 µg kg -1 . LODs were 0.27 and 0.26 µg kg -1 while LOQs were fixed at 1.0 and 1.2 µg kg -1 for OTA and OTα, respectively. Main recoveries for OTA ranged from 82 to 109% and for OTα ranged from 55 to 89%. The values of within-laboratory relative standard deviation (RSD r ) were equal to or below 20%. Considering the results obtained and that all analytical performance criteria were fulfilled, the new extraction and purification method developed for OTA and OTα determination in animal tissues and eggs was found appropriate for control laboratories and research activities designed to ensure food safety.

  10. Development and validation of an LC-MS/MS method to quantify lysergic acid diethylamide (LSD), iso-LSD, 2-oxo-3-hydroxy-LSD, and nor-LSD and identify novel metabolites in plasma samples in a controlled clinical trial

    OpenAIRE

    Dolder, Patrick C.; Liechti, Matthias E.; Rentsch, Katharina M.

    2018-01-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of this study was to develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantification of LSD, iso-LSD, 2-oxo-3-hydroxy LSD (O-H-LSD), and nor-LSD in plasma samples from 24 healthy subjects after controlled administration of 100 μg LSD in a clinical trial. In addition, metabolites that have been recently described in in vitro studies, including lysergic acid monoethylamide...

  11. Validation of an semi-automated multi component method using protein precipitation LC-MS-MS for the analysis of whole blood samples

    DEFF Research Database (Denmark)

    Slots, Tina

    BACKGROUND: Solid phase extraction (SPE) are one of many multi-component methods, but can be very time-consuming and labour-intensive. Protein precipitation is, on the other hand, a much simpler and faster sample pre-treatment than SPE, and protein precipitation also has the ability to cover a wi......-mortem whole blood sample preparation for toxicological analysis; from the primary sample tube to a 96-deepwell plate ready for injection on the liquid chromatography mass spectrometry (LC-MS/MS)....

  12. A validated specific stability-indicating RP-HPLC assay method for Ambrisentan and its related substances.

    Science.gov (United States)

    Narayana, M B V; Chandrasekhar, K B; Rao, B M

    2014-09-01

    A validated specific stability-indicating reverse-phase liquid chromatographic method was developed for the quantitative determination of Ambrisentan as well as its related substances in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its related impurities. Forced degradation studies were performed on bulk samples of Ambrisentan as per the ICH-prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability-indicating power of the LC method. Significant degradation in acidic, basic stress conditions was observed and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from the forced degradation studies and the impurity-spiked solution. Good resolution between the peaks corresponds to Ambrisentan-related impurities and degradation products from the analyte were achieved on a SunFire C18 column using a mobile phase consisting of a mixture of potassium dihydrogen orthophosphate at a pH adjusted to 2.5 with ortho-phosphoric acid in water and a mixture of acetonitrile:methanol using a simple linear gradient. The detection was carried out at 225 nm. The limit of detection and the limit of quantification for the Ambrisentan and its related impurities were established. The stressed test solutions were assayed against the qualified working standard of Ambrisentan and the mass balance in each case was between 98.9 and 100.3%, indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per the ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Ambrisentan at the time of batch release and also during its storage (long-term and accelerated stability). © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.

    Science.gov (United States)

    Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael

    2017-03-01

    A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Rapid and reliable QuEChERS-based LC-MS/MS method for determination of acrylamide in potato chips and roasted coffee

    Science.gov (United States)

    Stefanović, S.; Đorđevic, V.; Jelušić, V.

    2017-09-01

    The aim of this paper is to verify the performance characteristics and fitness for purpose of rapid and simple QuEChERS-based LC-MS/MS method for determination of acrylamide in potato chips and coffee. LC-MS/MS is by far the most suitable analytical technique for acrylamide measurements given its inherent sensitivity and selectivity, as well as capability of analyzing underivatized molecule. Acrylamide in roasted coffee and potato chips wasextracted with water:acetonitrile mixture using NaCl and MgSO4. Cleanup was carried out with MgSO4 and PSA. Obtained results were satisfactory. Recoveries were in the range of 85-112%, interlaboratory reproducibility (Cv) was 5.8-7.6% and linearity (R2) was in the range of 0.995-0.999. LoQ was 35 μg kg-1 for coffee and 20 μg kg-1 for potato chips. Performance characteristic of the method are compliant with criteria for analytical methods validation. Presented method for quantitative determination of acrylamide in roasted coffee and potato chips is fit for purposes of self-control in food industry as well as regulatory controls carried out by the governmental agencies.

  15. Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development

    Science.gov (United States)

    Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei

    2014-01-01

    Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring

  16. Multiresidue method for detection of pesticides in beef meat using liquid chromatography coupled to mass spectrometry detection (LC-MS) after QuEChERS extraction.

    Science.gov (United States)

    Oliveira, Fabiano Aurélio da Silva; Pereira, Elba Nathália Corrêa; Gobbi, Jennifer Mattedi; Soto-Blanco, Benito; Melo, Marília Martins

    2018-01-01

    Beef meat is an important food that can be contaminated by pesticides. This study aimed to optimize a multiresidue method for identification and quantification of pesticides in beef meat by liquid chromatography coupled to mass spectrometry detection (LC-MS). The extraction and clean-up procedures were adapted from the QuECHERS method. From the 188 analytes tested, the method was validated as qualitative method for 19 compounds and as quantitative method for 152 compounds. The results were satisfactory, yielding coefficients of variation of less than 20% and recoveries ranging from 70% to 120% and expanded uncertainty of less than 50%. The quantification limit was typically 10 µg kg -1 (but 25 µg kg -1 for 12 of the compounds) and the detection limit was 5.0 µg kg -1 . Thirty-two real samples of commercialized beef meat were analyzed without any residual pesticide being found. Thus, the results showed that the multiresidue method for detecting 171 pesticides, using adapted QuECHERS for extraction and LC-MS for detection, is suitable for analyzing beef meat.

  17. Validation of LC-TOF-MS screening for drugs, metabolites, and collateral compounds in forensic toxicology specimens.

    Science.gov (United States)

    Guale, Fessessework; Shahreza, Shahriar; Walterscheid, Jeffrey P; Chen, Hsin-Hung; Arndt, Crystal; Kelly, Anna T; Mozayani, Ashraf

    2013-01-01

    Liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS) analysis provides an expansive technique for identifying many known and unknown analytes. This study developed a screening method that utilizes automated solid-phase extraction to purify a wide array of analytes involving stimulants, benzodiazepines, opiates, muscle relaxants, hypnotics, antihistamines, antidepressants and newer synthetic "Spice/K2" cannabinoids and cathinone "bath salt" designer drugs. The extract was applied to LC-TOF-MS analysis, implementing a 13 min chromatography gradient with mobile phases of ammonium formate and methanol using positive mode electrospray. Several common drugs and metabolites can share the same mass and chemical formula among unrelated compounds, but they are structurally different. In this method, the LC-TOF-MS was able to resolve many isobaric compounds by accurate mass correlation within 15 ppm mass units and a narrow retention time interval of less than 10 s of separation. Drug recovery yields varied among spiked compounds, but resulted in overall robust area counts to deliver an average match score of 86 when compared to the retention time and mass of authentic standards. In summary, this method represents a rapid, enhanced screen for blood and urine specimens in postmortem, driving under the influence, and drug facilitated sexual assault forensic toxicology casework.

  18. Elaboration and validation of the method for the quantification of the emetic toxin of Bacillus cereus as described in EN-ISO 18465 - Microbiology of the food chain - Quantitative determination of emetic toxin (cereulide) using LC-MS/MS.

    Science.gov (United States)

    In 't Veld, P H; van der Laak, L F J; van Zon, M; Biesta-Peters, E G

    2018-04-12

    A method for the quantification of the Bacillus cereus emetic toxin (cereulide) was developed and validated. The method principle is based on LC-MS as this is the most sensitive and specific method for cereulide. Therefore the study design is different from the microbiological methods validated under this mandate. As the method had to be developed a two stage validation study approach was used. The first stage (pre-study) focussed on the method applicability and the experience of the laboratories with the method. Based on the outcome of the pre-study and comments received during voting at CEN and ISO level a final method was agreed to be used for the second stage the (final) validation of the method. In the final (validation) study samples of cooked rice (both artificially contaminated with cereulide or contaminated with B. cereus for production of cereulide in the rice) and 6 other food matrices (fried rice dish, cream pastry with chocolate, hotdog sausage, mini pancakes, vanilla custard and infant formula) were used. All these samples were spiked by the participating laboratories using standard solutions of cereulide supplied by the organising laboratory. The results of the study indicate that the method is fit for purpose. Repeatability values were obtained of 0.6 μg/kg at low level spike (ca. 5 μg/kg) and 7 to 9.6 μg/kg at high level spike (ca. 75 μg/kg). Reproducibility at low spike level ranged from 0.6 to 0.9 μg/kg and from 8.7 to 14.5 μg/kg at high spike level. Recovery from the spiked samples ranged between 96.5% for mini-pancakes to 99.3% for fries rice dish. Copyright © 2018. Published by Elsevier B.V.

  19. Volumetric adsorptive microsampling-liquid chromatography tandem mass spectrometry assay for the simultaneous quantification of four antibiotics in human blood: Method development, validation and comparison with dried blood spot.

    Science.gov (United States)

    Barco, Sebastiano; Castagnola, Elio; Moscatelli, Andrea; Rudge, James; Tripodi, Gino; Cangemi, Giuliana

    2017-10-25

    In this paper we show the development and validation of a volumetric absorptive microsampling (VAMS™)-LC-MS/MS method for the simultaneous quantification of four antibiotics: piperacillin-tazobactam, meropenem, linezolid and ceftazidime in 10μL human blood. The novel VAMS-LC-MS/MS method has been compared with a dried blood spot (DBS)-based method in terms of impact of hematocrit (HCT) on accuracy, reproducibility, recovery and matrix effect. Antibiotics were extracted from VAMS and DBS by protein precipitation with methanol after a re-hydration step at 37°C for 10min. LC-MS/MS was carried out on a Thermo Scientific™ TSQ Quantum™ Access MAX triple quadrupole coupled to an Accela ™UHPLC system. The VAMS-LC-MS/MS method is selective, precise and reproducible. In contrast to DBS, it allows an accurate quantification without any HCT influence. It has been applied to samples derived from pediatric patients under therapy. VAMS is a valid alternative sampling strategy for the quantification of antibiotics and is valuable in support of clinical PK/PD studies and consequently therapeutic drug monitoring (TDM) in pediatrics. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Improved LC-MS/MS method for the quantification of hepcidin-25 in clinical samples.

    Science.gov (United States)

    Abbas, Ioana M; Hoffmann, Holger; Montes-Bayón, María; Weller, Michael G

    2018-06-01

    Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the "sticky" character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing a LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend a LC-MS/MS-based quantification method with a dynamic range of 0.5-40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials. Graphical abstract Structure of hepcidin-25 (Protein Data Bank, PDB ID 2KEF).

  1. A new acetonitrile-free mobile phase method for LC-ELSD quantification of fructooligosaccharides in onion (Allium cepa L.).

    Science.gov (United States)

    Downes, Katherine; Terry, Leon A

    2010-06-30

    Onion soluble non-structural carbohydrates consist of fructose, glucose and sucrose plus fructooligosaccharides (FOS) with degrees of polymerisation (DP) in the range of 3-19. In onion, sugars and FOS are typically separated using liquid chromatography (LC) with acetonitrile (ACN) as a mobile phase. In recent times, however, the production of ACN has diminished due, in part, to the current worldwide economic recession. A study was therefore undertaken, to find an alternative LC method to quantify sugars and FOS from onion without the need for ACN. Two mobile phases were compared; the first taken from a paper by Vågen and Slimestad (2008) using ACN mobile phase, the second, a newly reported method using ethanol (EtOH). The EtOH mobile phase eluted similar concentrations of all FOS compared to the ACN mobile phase. In addition, limit of detection, limit of quantification and relative standard deviation values were sufficiently and consistently lower for all FOS using the EtOH mobile phase. The drawback of the EtOH mobile phase was mainly the inability to separate all individual sugar peaks, yet FOS could be successfully separated. However, using the same onion extract, a previously established LC method based on an isocratic water mobile phase could be used in a second run to separate sugars. Although the ACN mobile phase method is more convenient, in the current economic climate a method based on inexpensive and plentiful ethanol is a valid alternative and could potentially be applied to other fresh produce types. In addition to the mobile phase solvent, the effect of extraction solvents on sugar and FOS concentration was also investigated. EtOH is still widely used to extract sugars from onion although previous literature has concluded that MeOH is a superior solvent. For this reason, an EtOH-based extraction method was compared with a MeOH-based method to extract both sugars and FOS. The MeOH-based extraction method was more efficacious at extracting sugars and

  2. Validation of a multi-residue method for the determination of several antibiotic groups in honey by LC-MS/MS.

    Science.gov (United States)

    Bohm, Detlef A; Stachel, Carolin S; Gowik, Petra

    2012-07-01

    The presented multi-method was developed for the confirmation of 37 antibiotic substances from the six antibiotic groups: macrolides, lincosamides, quinolones, tetracyclines, pleuromutilines and diamino-pyrimidine derivatives. All substances were analysed simultaneously in a single analytical run with the same procedure, including an extraction with buffer, a clean-up by solid-phase extraction, and the measurement by liquid chromatography tandem mass spectrometry in ESI+ mode. The method was validated on the basis of an in-house validation concept with factorial design by combination of seven factors to check the robustness in a concentration range of 5-50 μg kg(-1). The honeys used were of different types with regard to colour and origin. The values calculated for the validation parameters-decision limit CCα (range, 7.5-12.9 μg kg(-1)), detection capability CCβ (range, 9.4-19.9 μg kg(-1)), within-laboratory reproducibility RSD(wR) (tylvalosin with 21.4 %), repeatability RSD(r) (tylvalosin with 21.1%), and recovery (range, 92-106%)-were acceptable and in agreement with the criteria of Commission Decision 2002/657/EC. The validation results showed that the method was applicable for the residue analysis of antibiotics in honey to substances with and without recommended concentrations, although some changes had been tested during validation to determine the robustness of the method.

  3. LC-MS/MS method for the determination of clodronate in human plasma.

    Science.gov (United States)

    Hasan, Mahmoud; Schumacher, Gitta; Seekamp, Anne; Taedken, Tobias; Siegmund, Werner; Oswald, Stefan

    2014-11-01

    Clodronate belongs to the class of bisphosphonates which are used for the treatment of bone disorders. Due to its high polarity it has a low and highly variable oral bioavailability which results in low plasma concentrations and requires sensitive bioanalytical methods to characterize its pharmacokinetics in human. Here, we describe for the first time the development and validation of a LC-MS/MS assay for the quantification of clodronate in human plasma. The bisphosphonate was isolated from the biological matrix by protein precipitation using perchloric acid (10%), and derivatized with trimethylorthoacetate prior sample clean-up with liquid-liquid extraction using methyl tert-butyl ether. The chromatography was performed using an isocratic elution with ammonium acetate 5mM (85% v/v, pH 3.8) and acetonitrile (15% v/v) as mobile phase with a flow rate of 300μl/min on a reversed-phase column (Supelco Ascentis(®), C18) temporized at 50°C. The mass spectrometric detection was done using the API4000 triple quadruple mass spectrometer monitoring the mass/charge transitions 301.0/145 for clodronate and 305.2/137.1 for the internal standard etidronate. The analytical range was set to 5-800ng/ml, allowing an evaluation of the plasma concentration-time profiles of clodronate for approximately 7-8 half-life (∼24h). The method was validated according to current FDA/EMA guidelines on bioanalytical method validation with respect to specificity, linearity, intra- and inter-day accuracy and precision, matrix effect, recovery as well as stability. The precision of the assay was 0.6-6.9% and 0.6-8.1% for the intra-day and inter-day variability, respectively. The intra-day and inter-day accuracy (error) was 0.6-8.8% and 2.2-4.5%. The recovery of the analyte was low (2-3%) but reproducible over the entire validation range and sufficient to monitor the target concentrations in human plasma. The drug was shown to be stable in plasma at room temperature for at least 3h (96.0±6%) and

  4. A new LC-ESI-MS/MS method to measure long-chain acylcarnitine levels in cultured cells

    International Nuclear Information System (INIS)

    Jauregui, Olga; Sierra, Adriana Y.; Carrasco, Patricia; Gratacos, Esther; Hegardt, Fausto G.; Casals, Nuria

    2007-01-01

    The quantitative evaluation of long-chain acylcarnitines in lipid extracts from cultured cells or tissues is a prerequisite to study carnitine palmitoyltransferase (CPT) activity. There is thus a need for the accurate measurement of the concentration of long-chain acylcarnitines at the lowest concentration present in lipid extracts. Here we report a fast and reliable quantitative method based on the use of weak acid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to quantify acylcarnitines through hydrophilic interaction chromatography. The method was validated using isotopic dilution and the results allow the analysis of a large number of samples at low concentration levels (down to 0.35 nmol L -1 for palmitoylcarnitine) with good inter- and intra-day precision. The method was used for the quantitative study of changes in concentration of palmitoylcarnitine and other acylcarnitines in PC-12 cells over-expressing CPT1a gene. It was also used to measure CPT1 activity in mitochondria isolated from transfected cells, giving similar results to the more common radiometric method, but with higher sensitivity

  5. A new LC-ESI-MS/MS method to measure long-chain acylcarnitine levels in cultured cells

    Energy Technology Data Exchange (ETDEWEB)

    Jauregui, Olga [Scientific and Technical Services, University of Barcelona (Spain); Sierra, Adriana Y.; Carrasco, Patricia; Gratacos, Esther [Molecular and Cellular Unit, School of Health Sciences, International University of Catalonia (Spain); Hegardt, Fausto G. [Department of Biochemistry and Molecular Biology, University of Barcelona, School of Pharmacy (Spain); Casals, Nuria [Molecular and Cellular Unit, School of Health Sciences, International University of Catalonia (Spain)], E-mail: ncasals@csc.uic.es

    2007-09-05

    The quantitative evaluation of long-chain acylcarnitines in lipid extracts from cultured cells or tissues is a prerequisite to study carnitine palmitoyltransferase (CPT) activity. There is thus a need for the accurate measurement of the concentration of long-chain acylcarnitines at the lowest concentration present in lipid extracts. Here we report a fast and reliable quantitative method based on the use of weak acid extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to quantify acylcarnitines through hydrophilic interaction chromatography. The method was validated using isotopic dilution and the results allow the analysis of a large number of samples at low concentration levels (down to 0.35 nmol L{sup -1} for palmitoylcarnitine) with good inter- and intra-day precision. The method was used for the quantitative study of changes in concentration of palmitoylcarnitine and other acylcarnitines in PC-12 cells over-expressing CPT1a gene. It was also used to measure CPT1 activity in mitochondria isolated from transfected cells, giving similar results to the more common radiometric method, but with higher sensitivity.

  6. Determination of chlormequat in pig serum and sow milk by LC-MS/MS

    DEFF Research Database (Denmark)

    Poulsen, Mette Erecius; Christensen, Hanne Bjerre; Sørensen, M.T.

    2007-01-01

    reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80...

  7. Development of a LC-MS/MS Method for the Simultaneous Detection of Tricarboxylic Acid Cycle Intermediates in a Range of Biological Matrices

    Directory of Open Access Journals (Sweden)

    Omar Al Kadhi

    2017-01-01

    Full Text Available It is now well-established that perturbations in the tricarboxylic acid (TCA cycle play an important role in the metabolic transformation occurring in cancer including that of the prostate. A method for simultaneous qualitative and quantitative analysis of TCA cycle intermediates in body fluids, tissues, and cultured cell lines of human origin was developed using a common C18 reversed-phase column by LC-MS/MS technique. This LC-MS/MS method for profiling TCA cycle intermediates offers significant advantages including simple and fast preparation of a wide range of human biological samples. The analytical method was validated according to the guideline of the Royal Society of Chemistry Analytical Methods Committee. The limits of detection were below 60 nM for most of the TCA intermediates with the exception of lactic and fumaric acids. The calibration curves of all TCA analytes showed linearity with correlation coefficients r2>0.9998. Recoveries were >95% for all TCA analytes. This method was established taking into consideration problems and limitations of existing techniques. We envisage that its application to different biological matrices will facilitate deeper understanding of the metabolic changes in the TCA cycle from in vitro, ex vivo, and in vivo studies.

  8. Development of a quantitative multi-compound method for the detection of 14 nitrogen-rich adulterants by LC-MS/MS in food materials.

    Science.gov (United States)

    Frank, Nancy; Bessaire, Thomas; Tarres, Adrienne; Goyon, Alexandre; Delatour, Thierry

    2017-11-01

    The increasing number of food frauds using exogenous nitrogen-rich adulterants to artificially raise the protein content for economically motivated adulteration has demonstrated the need for a robust analytical methodology. This method should be applicable for quality control in operations covering a wide range of analyte concentrations to be able to analyse high levels as usually found in adulteration, as well as low levels due to contamination. The paper describes a LC-MS/MS method covering 14 nitrogen-rich adulterants using a simple and fast sample preparation based on dilution and clean-up by dispersive SPE. Quantification is carried out by isotopic dilution reaching LOQs of 0.05-0.20 mg/kg in a broad range of food matrices (infant formula, liquid milk, dairy ingredient, high protein meal, cereal, infant cereal, and meat/fish powder). Validation of seven commodity groups was performed according to SANCO 12571/2013, giving satisfactory results demonstrating the method's fitness for purpose at the validated range at contamination level. Method ruggedness was further assessed by transferring the developed method into another laboratory devoted to routine testing for quality control. Next to the method description, emphasis is placed on challenges and problems appearing during method development as well as validation. They are discussed in detail and solutions are provided.

  9. Development and validation of a method for the analysis of Ochratoxin A in roasted coffee by liquid chromatography/electrospray-mass spectrometry in Tandem (LC/ESI-MS/MS

    Directory of Open Access Journals (Sweden)

    Raquel D. C. C. Bandeira

    2012-01-01

    Full Text Available A method using LC/ESI-MS/MS for the quantitative analysis of Ochratoxin A in roasted coffee was described. Linearity was demonstrated (r = 0.9175. The limits of detection and quantification were 1.0 and 3.0 ng g-1, respectively. Trueness, repeatability and intermediate precision values were 89.0-108.8%; 2.4-13.7%; 12.5-17.8%, respectively. To the best of our knowledge, this is the first report in which Ochratoxin A in roasted coffee is analysed by LC/ESI-MS/MS, contributing to the field of mycotoxin analysis, and it will be used for future production of Certified Reference Material.

  10. Validation of high-performance liquid chromatographic method for analysis of fluconazole in microemulsions and liquid crystals

    Directory of Open Access Journals (Sweden)

    Hilris Rocha e Silva

    2014-04-01

    Full Text Available In recent decades, there has been a significant increase in the incidence of fungal diseases. Certain fungal diseases cause cutaneous lesions and in the usual treatment, generally administred orally, the drug reaches the site of action with difficulty and its concentration is too low. An approach much explored in recent years is the development of nanotechnology-based drug delivery systems, and microemulsions (ME and liquid crystals (LC are promising. ME and LC were developed with oleic acid or copaiba oil as the oil phase, propoxyl (5OP ethoxyl (20 OE cetyl alcohol as surfactant and water. An analytical method to assess the incorporation of fluconazole (FLU in the systems under study was validated according to guidelines of the International Conference on Harmonization (ICH guidelines and the Brazilian Food, Drug and Sanitation Agency (ANVISA. The method was conducted on a C18-RP column (250 × 4.6 mm i.d., maintained at room temperature. The mobile phase consisted of acetonitrile and water (50:50, v/v, run at a flow rate of 1.0mL/min and using ultraviolet detection at 210nm. The chromatographic separation was obtained with a retention time of 6.3min, and was linear in the range of 20-400 µg/mL (r2=0.9999. The specificity showed no interference of the excipients. The accuracy was 100.76%. The limits of detection and quantitation were 0.057 and 0.172 µg.mL-1, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the incorporation of FLU in ME and LC, contributing to improve the quality control and to assure the therapeutic efficacy.

  11. Development and validation of an LC-MS/MS method for simultaneous quantification of levodopa and MD01 in rat plasma and its application to a pharmacokinetic study of mucuna pruriens extract.

    Science.gov (United States)

    Yang, Guangjie; Zhang, Fangrong; Deng, Linfang; Chen, Chang; Cheng, Zhongzhe; Huang, Jiangeng; Liu, Jiangyun; Jiang, Hongliang

    2016-09-01

    Mucuna pruriens, an ancient Indian herbal medicine containing levodopa, is widely used for Parkinson's disease. In order to simultaneously determine levodopa and 1,1-dimethyl-3-carboxy-6,7-dihydroxy-1,2,3,4-tetrahydroisoquinoline (MD01) in rat plasma, an improved LC-MS/MS method was developed and validated for a pharmacokinetic study in rats orally administered levodopa or Mucuna pruriens extract (MPE). Elimination of matrix effect and improvement of extraction recovery were achieved through systematic optimization of reversed-phase and hydrophilic interaction chromatographic conditions together with sample clean-up procedures. A satisfactory chromatographic performance was obtained with a Thermo Aquasil C18 column (50 × 2.1 mm, 3 µm) using acetonitrile and water containing 0.2% formic acid as mobile phases. Futhermore, sodium metabisulfite and formic acid were used as stabilizers in neat solutions as well as rat plasma. The method was validated in a dynamic range of 20.0-10,000 ng/mL for levodopa and MD01; the intra- and inter-day precision and accuracy were acceptable. The method was successfully utilized to determine the levodopa level in plasma samples of rats administered levodopa or MPE. Pharmacokinetic results showed that an increase in the AUC of levodopa was observed in rats following oral administration of multiple doses of MPE. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Ultra-sensitive LC-MS/MS method for the quantification of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine in human plasma for a microdose clinical trial.

    Science.gov (United States)

    van Nuland, M; Hillebrand, M J X; Rosing, H; Burgers, J A; Schellens, J H M; Beijnen, J H

    2018-03-20

    In microdose clinical trials a maximum of 100 μg of drug substance is administered to participants, in order to determine the pharmacokinetic properties of the agents. Measuring low plasma concentrations after administration of a microdose is challenging and requires the use of ulta-sensitive equipment. Novel liquid chromatography-mass spectrometry (LC-MS/MS) platforms can be used for quantification of low drug plasma levels. Here we describe the development and validation of an LC-MS/MS method for quantification of gemcitabine and its metabolite 2',2'-difluorodeoxyuridine (dFdU) in the low picogram per milliliter range to support a microdose trial. The validated assay ranges from 2.5-500 pg/mL for gemcitabine and 250-50,000 pg/mL for dFdU were linear, with a correlation coefficient (r 2 ) of 0.996 or better. Sample preparation with solid phase extraction provided a good and reproducible recovery. All results were within the acceptance criteria of the latest US FDA guidance and EMA guidelines. In addition, the method was successfully applied to measure plasma concentrations of gemcitabine in a patient after administration of a microdose of gemcitabine. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Orthogonal analytical methods for botanical standardization: determination of green tea catechins by qNMR and LC-MS/MS.

    Science.gov (United States)

    Napolitano, José G; Gödecke, Tanja; Lankin, David C; Jaki, Birgit U; McAlpine, James B; Chen, Shao-Nong; Pauli, Guido F

    2014-05-01

    The development of analytical methods for parallel characterization of multiple phytoconstituents is essential to advance the quality control of herbal products. While chemical standardization is commonly carried out by targeted analysis using gas or liquid chromatography-based methods, more universal approaches based on quantitative (1)H NMR (qHNMR) measurements are being used increasingly in the multi-targeted assessment of these complex mixtures. The present study describes the development of a 1D qHNMR-based method for simultaneous identification and quantification of green tea constituents. This approach utilizes computer-assisted (1)H iterative Full Spin Analysis (HiFSA) and enables rapid profiling of seven catechins in commercial green tea extracts. The qHNMR results were cross-validated against quantitative profiles obtained with an orthogonal LC-MS/MS method. The relative strengths and weaknesses of both approaches are discussed, with special emphasis on the role of identical reference standards in qualitative and quantitative analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Analysis of catecholamines in urine by unique LC/MS suitable ion-pairing chromatography.

    Science.gov (United States)

    Bergmann, Marianne L; Sadjadi, Seyed; Schmedes, Anne

    2017-07-01

    The catecholamines, epinephrine (E) and norepinephrine (NE) are small polar, hydrophilic molecules, posing significant challenges to liquid chromatography - tandem mass spectrometry (LC-MS/MS) method development. Specifically, these compounds show little retention on conventional reversed-phase liquid chromatography columns. This work presents development and validation of an LC-MS/MS method for determining catecholamines in urine, based on a new approach to ion-pairing chromatography (IPC), in which the ion-pairing reagent (IPR), 1-Heptane Sulfonic Acid (HSA), is added to the extracted samples instead of the mobile phases. A Hamilton STARlet workstation carried out the solid phase extraction of urine samples. The extracted samples were diluted with 60mmol/L HSA and injected on a Kinetex core-shell biphenyl column with conventional LC-MS/MS suitable mobile phases. Chromatographic separation of E and NE was achieved successfully with very stable retention times (RT). In 484 injections, the RTs were steady with a CV of less than ±4%. Furthermore, HSA was separated from E and NE, allowing HSA to be diverted to waste instead of entering the mass spectrometer ion chamber. The method was validated with good analytical performance, and even though the analysis for urinary catecholamines is increasingly being replaced by plasma free metanephrines in diagnosing pheochromocytomas, this work represents the application of a new analytical technique that can be transferred to other small polar molecules, that are difficult to chromatograph on traditional reversed phase columns. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. LC-MS/MS method for the simultaneous determination of PA-824, moxifloxacin and pyrazinamide in rat plasma and its application to pharmacokinetic study.

    Science.gov (United States)

    Wang, Libin; Xu, Yue; Liang, Li; Diao, Chunyan; Liu, Xueying; Zhang, Jianchun; Zhang, Shengyong

    2014-08-01

    A simple, sensitive and rapid LC-MS/MS method has been developed and validated for simultaneous determination of PA-824, moxifloxacin, and pyrazinamide in rat plasma using metronidazole as internal standard. Sample preparation involved a simple one-step protein precipitation with methanol, followed by centrifugation and evaporation of the organic solvent. The residue was redissolved in mobile phase and analyzed by LC-MS/MS. An Inertsil(®) ODS3 C18 column (150mm×4.6mm, 5μm), a mobile phase composed of methanol-0.03% TEA (triethylamine) in water (85:15, v/v), and a flow rate of 0.5mL/min were employed, and the total run time was 6.0min. The mass spectrometer was run in positive ion ESI-APCI combined mode using multiple reaction monitoring (MRM) to monitor the mass transitions. The method was validated for accuracy, precision, linearity, range, selectivity, lower limit of quantification (LLOQ), recovery, and matrix effect. All validation parameters met the acceptance criteria according to regulatory guidelines. The LLOQ was 1.0μg/mL for pyrazinamide and 0.1μg/mL for PA-824 and moxifloxacin. The recoveries obtained for PA-824, moxifloxacin and pyrazinamide were ≥85%. Intra-day and inter-day coefficients of variation were less than 10%. The method had been successfully applied to a pharmacokinetic study of fixed dose administration of PA-824, moxifloxacin, pyrazinamide and their combination in SD rat. Significant differences of Tmax, Cmax, AUC(0-t) and CLz/F were observed between the single and combined groups after equal dose of PA-824 and moxifloxacin administration, which revealed the possibility of drug-drug interaction (DDI) between the PaMZ combination. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. UNE-EN ISO/IEC 17025:2005-accredited method for the determination of pesticide residues in fruit and vegetable samples by LC-MS/MS.

    Science.gov (United States)

    Camino-Sánchez, F J; Zafra-Gómez, A; Oliver-Rodríguez, B; Ballesteros, O; Navalón, A; Crovetto, G; Vílchez, J L

    2010-11-01

    A rapid, simple and sensitive multi-residue method was developed and validated for the simultaneous quantification and confirmation of 69 pesticides in fruit and vegetables using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted following the quick, easy, cheap, effective, rugged and safe method known as QuEChERS. Mass spectrometric conditions were individually optimised for each analyte in order to achieve maximum sensitivity in multiple reaction monitoring (MRM) mode. Using the developed chromatographic conditions, 69 pesticides can be separated in less than 17 min. Two selected reaction monitoring (SRM) assays were used for each pesticide to obtain simultaneous quantification and identification in one run. With this method in SRM mode, more than 150 pesticides can be analysed and quantified, but their confirmation is not possible in all cases according to the European regulations on pesticide residues. Nine common representative matrices (zucchini, melon, cucumber, watermelon, tomato, garlic, eggplant, lettuce and pepper) were selected to investigate the effect of different matrices on recovery and precision. Mean recoveries ranged from 70% to 120%, with relative standard deviations (RSDs) lower than 20% for all the pesticides. The proposed method was applied to the analysis of more than 2000 vegetable samples from the extensive greenhouse cultivation in the province of Almeria, Spain, during one year. The methodology combines the advantages of both QuEChERS and LC-MS/MS producing a very rapid, sensitive, accurate and reliable procedure that can be applied in routine analytical laboratories. The method was validated and accredited according to UNE-EN-ISO/IEC 17025:2005 international standard (accreditation number 278/LE1027).

  17. Analytical techniques and method validation for the measurement of selected semivolatile and nonvolatile organofluorochemicals in air.

    Science.gov (United States)

    Reagen, William K; Lindstrom, Kent R; Thompson, Kathy L; Flaherty, John M

    2004-09-01

    The widespread use of semi- and nonvolatile organofluorochemicals in industrial facilities, concern about their persistence, and relatively recent advancements in liquid chromatography/mass spectrometry (LC/MS) technology have led to the development of new analytical methods to assess potential worker exposure to airborne organofluorochemicals. Techniques were evaluated for the determination of 19 organofluorochemicals and for total fluorine in ambient air samples. Due to the potential biphasic nature of most of these fluorochemicals when airborne, Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were used to simultaneously trap fluorochemical particulates and vapors from workplace air. Analytical methods were developed for OVS air samples to quantitatively analyze for total fluorine using oxygen bomb combustion/ion selective electrode and for 17 organofluorochemicals using LC/MS and gas chromatography/mass spectrometry (GC/MS). The experimental design for this validation was based on the National Institute of Occupational Safety and Health (NIOSH) Guidelines for Air Sampling and Analytical Method Development and Evaluation, with some revisions of the experimental design. The study design incorporated experiments to determine analytical recovery and stability, sampler capacity, the effect of some environmental parameters on recoveries, storage stability, limits of detection, precision, and accuracy. Fluorochemical mixtures were spiked onto each OVS tube over a range of 0.06-6 microg for each of 12 compounds analyzed by LC/MS and 0.3-30 microg for 5 compounds analyzed by GC/MS. These ranges allowed reliable quantitation at 0.001-0.1 mg/m3 in general for LC/MS analytes and 0.005-0.5 mg/m3 for GC/MS analytes when 60 L of air are sampled. The organofluorochemical exposure guideline (EG) is currently 0.1 mg/m3 for many analytes, with one exception being ammonium perfluorooctanoate (EG is 0.01 mg/m3). Total fluorine results may be used

  18. Development and Validation of LC Method for the Determination of Famciclovir in Pharmaceutical Formulation Using an Experimental Design

    Directory of Open Access Journals (Sweden)

    Srinivas Vishnumulaka

    2008-01-01

    Full Text Available A rapid and sensitive RP-HPLC method with UV detection (242 nm for routine analysis of famciclovir in pharmaceutical formulations was developed. Chromatography was performed with mobile phase containing a mixture of methanol and phosphate buffer (50:50, v/v with flow rate 1.0 mL min−1. Quantitation was accomplished with internal standard method. The procedure was validated for linearity (correlation coefficient =0.9999, accuracy, robustness and intermediate precision. Experimental design was used for validation of robustness and intermediate precision. To test robustness, three factors were considered; percentage v/v of methanol in mobile phase, flow rate and pH; flow rate, the percentage of organic modifier and pH have considerable important effect on the response. For intermediate precision measure the variables considered were: analyst, equipment and number of days. The RSD value (0.86%, n=24 indicated an acceptable precision of the analytical method. The proposed method was simple, sensitive, precise, accurate and quick and useful for routine quality control.

  19. Development and validation of an LC-MS/MS method for the determination of mesalazine in beagle dog plasma and its application to a pharmacokinetic study.

    Science.gov (United States)

    Qin, Juan; Di, Xin; Wang, Xin; Liu, Youping

    2015-02-01

    A simple, specific and sensitive LC-MS/MS method was developed and validated for the determination of mesalazine in beagle dog plasma. The plasma samples were prepared by protein precipitation, then the separation of the analyte was achieved on a Waters Spherisorb C6 column (150 × 4.6 mm, 5 µm) with a mobile phase consisting of 0.2% formic acid in water-methanol (20:80, v/v). The flow rate was set at 1.0 mL/min with a split ratio of 3:2. Mass spectrometric detection was achieved by a triple-quadrupole mass spectrometer equipped with an electrospray source interface in positive ionization mode. Quantitation was performed using selected reaction monitoring of precursor-product ion transitions at m/z 154 → m/z 108 for mesalazine and m/z 285 → m/z 193 for diazepam (internal standard). The linear calibration curve of mesalazine was obtained over the concentration range 50-30,000 ng/mL. The matrix effect of mesalazine was within ±9.8%. The intra- and inter-day precisions were dogs after rectal administration of mesalazine suppository. Copyright © 2014 John Wiley & Sons, Ltd.

  20. An improved method for fast and selective separation of carotenoids by LC-MS.

    Science.gov (United States)

    Abate-Pella, Daniel; Freund, Dana M; Slovin, Janet P; Hegeman, Adrian D; Cohen, Jerry D

    2017-11-01

    Carotenoids are a large class of compounds that are biosynthesized by condensation of isoprene units in plants, fungi, bacteria, and some animals. They are characteristically highly conjugated through double bonds, which lead to many isomers as well susceptibility to oxidation and other chemical modifications. Carotenoids are important because of their potent antioxidant activity and are the pigments responsible for color in a wide variety of foods. Human consumption is correlated to many health benefits including prevention of cancer, cardiovascular disease, and age-related disease. Extreme hydrophobicity, poor stability, and low concentration in biological samples make these compounds difficult to analyze and difficult to develop analytical methods for aimed towards identification and quantification. Examples in the literature frequently report the use of exotic stationary phases, solvents, and additives, such as ethyl acetate, dichloromethane, and methyl tert-butyl ether that are incompatible with liquid chromatography mass spectrometry (LC-MS). In order to address these issues, we implemented the use of LC-MS friendly conditions using a low-hydrophobicity cyano-propyl column (Agilent Zorbax SB-CN). We successfully differentiated between isomeric carotenoids by optimizing two gradient methods and using a mixture of 11 standards and LC-MS in positive ionization mode. Three complex biological samples from strawberry leaf, chicken feed supplement, and the photosynthetic bacterium Chloroflexus aurantiacus were analyzed and several carotenoids were resolved in these diverse backgrounds. Our results show this methodology is a significant improvement over other alternatives for analyzing carotenoids because of its ease of use, rapid analysis time, high selectivity, and, most importantly, its compatibility with typical LC-MS conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.

    Science.gov (United States)

    Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil

    2015-10-01

    Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    Science.gov (United States)

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  3. Liquid-chromatography mass spectrometry (LC-MS) of steroid hormone metabolites and its applications

    Science.gov (United States)

    Penning, Trevor M.; Lee, Seon-Hwa; Jin, Yi; Gutierrez, Alejandro; Blair, Ian A.

    2010-01-01

    Advances in liquid chromatography-mass spectrometry (LC-MS) can be used to measure steroid hormone metabolites in vitro and in vivo. We find that LC-Electrospray Ionization (ESI)-MS using a LCQ ion trap mass spectrometer in the negative ion mode can be used to monitor the product profile that results from 5α–dihydrotestosterone(DHT)-17β-glucuronide, DHT-17β-sulfate, and tibolone-17β-sulfate reduction catalyzed by human members of the aldo-keto reductase (AKR) 1C subfamily and assign kinetic constants to these reactions. We also developed a stable-isotope dilution LC-electron capture atmospheric pressure chemical ionization (ECAPCI)-MS method for the quantitative analysis of estrone (E1) and its metabolites as pentafluorobenzyl (PFB) derivatives in human plasma in the attomole range. The limit of detection for E1-PFB was 740 attomole on column. Separations can be performed using normal-phase LC because ionization takes place in the gas phase rather than in solution. This permits efficient separation of the regioisomeric 2- and 4-methoxy-E1. The method was validated for the simultaneous analysis of plasma E2 and its metabolites: 2-methoxy-E2, 4-methoxy-E2, 16α-hydroxy-E2, estrone (E1), 2-methoxy-E1, 4-methoxy-EI, and 16α-hydroxy-E1 from 5 pg/mL to 2,000 pg/mL. Our LC-MS methods have sufficient sensitivity to detect steroid hormone levels in prostate and breast tumors and should aid their molecular diagnosis and treatment. PMID:20083198

  4. A new high-throughput LC-MS method for the analysis of complex fructan mixtures

    DEFF Research Database (Denmark)

    Verspreet, Joran; Hansen, Anders Holmgaard; Dornez, Emmie

    2014-01-01

    In this paper, a new liquid chromatography-mass spectrometry (LC-MS) method for the analysis of complex fructan mixtures is presented. In this method, columns with a trifunctional C18 alkyl stationary phase (T3) were used and their performance compared with that of a porous graphitized carbon (PGC...

  5. Validation of an enzyme-linked immunosorbent assay screening method and a liquid chromatography-tandem mass spectrometry confirmation method for the identification and quantification of ketamine and norketamine in urine samples from Malaysia.

    Science.gov (United States)

    Harun, Norlida; Anderson, Robert A; Miller, Eleanor I

    2009-01-01

    An ELISA and a liquid chromatography-tandem mass spectrometry (LC-MS-MS) confirmation method were developed and validated for the identification and quantitation of ketamine and its major metabolite norketamine in urine samples. The Neogen ketamine microplate ELISA was optimized with respect to sample and enzyme conjugate volumes and the sample preincubation time before addition of the enzyme conjugate. The ELISA kit was validated to include an assessment of the dose-response curve, intra- and interday precision, limit of detection (LOD), and cross-reactivity. The sensitivity and specificity were calculated by comparison to the results from the validated LC-MS-MS confirmation method. An LC-MS-MS method was developed and validated with respect to LOD, lower limit of quantitation (LLOQ), linearity, recovery, intra- and interday precision, and matrix effects. The ELISA dose-response curve was a typical S-shaped binding curve, with a linear portion of the graph observed between 25 and 500 ng/mL for ketamine. The cross-reactivity of 200 ng/mL norketamine to ketamine was 2.1%, and no cross-reactivity was detected with 13 common drugs tested at 10,000 ng/mL. The ELISA LOD was calculated to be 5 ng/mL. Both intra- (n = 10) and interday (n = 50) precisions were below 5.0% at 25 ng/mL. The LOD for ketamine and norketamine was calculated statistically to be 0.6 ng/mL. The LLOQ values were also calculated statistically and were 1.9 ng/mL and 2.1 ng/mL for ketamine and norketamine, respectively. The test linearity was 0-1200 ng/mL with correlation coefficient (R(2)) > 0.99 for both analytes. Recoveries at 50, 500, and 1000 ng/mL range from 97.9% to 113.3%. Intra- (n = 5) and interday (n = 25) precisions between extracts for ketamine and norketamine were excellent (Royal Malaysian Police. Ketamine concentrations detected by LC-MS-MS ranged from 22 to 31,670 ng/mL, and norketamine concentrations ranged from 25 to 10,990 ng/mL. The concentrations of ketamine and norketamine

  6. Can LC and LC-MS ever replace immunoassays?

    Directory of Open Access Journals (Sweden)

    Timothy G. Cross

    2016-10-01

    Full Text Available Immunoassays have been the technology of choice for the analysis of biomolecules for many decades across a wide range of applications in research, diagnostics and infectious disease monitoring. There are good reasons for the wide adoption of immunoassays but even such a well established and characterised technique has limitations and as such investigators are looking at alternative technologies. One such alternative is liquid chromatography (LC and, more specifically, liquid chromatography coupled with mass spectrometry (LC-MS. This article will review both immunoassay and LC and LC-MS technologies and methodologies and discuss the advantages and limitations of both approaches. In addition, the next developments that will need to occur before there is widespread adoption of LC and LC-MS technology preferentially over immunoassays will be examined.

  7. Determination of esculentoside A in dog plasma by LC-MS/MS method: application to pre-clinical pharmacokinetics.

    Science.gov (United States)

    Guan, Xiaoduo; Chang, Huichao; Sun, Fanlu; Chen, Xiaohui; Zhang, Wen; Fan, Guorong

    2013-01-01

    A simple and rapid high performance liquid chromatography electrospray ionization ion-trap tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of esculentoside A (EsA) in dog plasma using ginsenoside Rg1 as the internal standard (IS). After liquid-liquid extraction (LLE) with n-butanol, the analyte and IS were separated on a Diamonsil C(18) (2.1 mm × 50 mm, 3 μm) column with the mobile phase of methanol-water containing 0.1% acetic acid (70:30, v/v) at a flow rate of 0.2 ml/min. An ion trap mass spectrometer equipped with an electrospray ionization source performed in selected reaction monitoring (SRM) mode was used as the detector. The precursor-product ion transitions were m/z 849.3 [M+Na](+)→m/z 805.3 for EsA and m/z 823.3 [M+Na](+)→m/z 643.3 for IS. The total chromatographic run time was 5 min. The method was sensitive enough with a lower limit of quantitation (LLOQ) of 5 ng/ml and had a good linearity (r(2)>0.997) over the linear range of 5-500 ng/ml. The mean extraction recovery of EsA from spiked plasma samples was over 75%. The intra- and inter-precisions were no more than 8.8% and accuracies were within the range of -4.6 to 8.7%. All the validated data were within the accepted criteria as stated in the FDA bioanalytical method validation guideline. The developed method was suitable for the quantification of EsA and successfully applied to the pharmacokinetic study of EsA after an oral administration to beagle dogs. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Determination of Ten Corticosteroids in Illegal Cosmetic Products by a Simple, Rapid, and High-Performance LC-MS/MS Method

    Directory of Open Access Journals (Sweden)

    Vita Giaccone

    2017-01-01

    Full Text Available The aim of our present work was the development of a rapid high-performance liquid chromatography method with electrospray ionization and tandem mass spectrometry detection (LC-ESI-MS/MS for the determination of several corticosteroids in cosmetic products. Corticosteroids are suspected to be illegally added in cosmetic preparations in order to enhance the curative effect against some skin diseases. Sample preparation step consists in a single extraction with acetonitrile followed by centrifugation and filtration. The compounds were separated by reversed-phase chromatography with water and acetonitrile (both with 0.1% formic acid gradient elution and detected by ESI-MS positive and negative ionization mode. The method was validated at the validation level of 0.1 mg kg−1. Linearity was studied in the 5–250 μg L−1 range and linear coefficients (r2 were all over 0.99. The accuracy and precision of the method were satisfactory. The LOD ranged from 0.085 to 0.109 mg kg−1 and the LOQ from 0.102 to 0.121 mg kg−1. Mean recoveries for all the analytes were within the range 91.9–99.2%. The developed method is sensitive and useful for detection, quantification, and confirmation of these corticosteroids in cosmetic preparations and can be applied in the analysis of the suspected samples under investigation.

  9. Validation of a LC-MS/MS method for quantifying urinary nicotine, six nicotine metabolites and the minor tobacco alkaloids--anatabine and anabasine--in smokers' urine.

    Directory of Open Access Journals (Sweden)

    James E McGuffey

    Full Text Available Tobacco use is a major contributor to premature morbidity and mortality. The measurement of nicotine and its metabolites in urine is a valuable tool for evaluating nicotine exposure and for nicotine metabolic profiling--i.e., metabolite ratios. In addition, the minor tobacco alkaloids--anabasine and anatabine--can be useful for monitoring compliance in smoking cessation programs that use nicotine replacement therapy. Because of an increasing demand for the measurement of urinary nicotine metabolites, we developed a rapid, low-cost method that uses isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS for simultaneously quantifying nicotine, six nicotine metabolites, and two minor tobacco alkaloids in smokers' urine. This method enzymatically hydrolyzes conjugated nicotine (primarily glucuronides and its metabolites. We then use acetone pretreatment to precipitate matrix components (endogenous proteins, salts, phospholipids, and exogenous enzyme that may interfere with LC-MS/MS analysis. Subsequently, analytes (nicotine, cotinine, hydroxycotinine, norcotinine, nornicotine, cotinine N-oxide, nicotine 1'-N-oxide, anatabine, and anabasine are chromatographically resolved within a cycle time of 13.5 minutes. The optimized assay produces linear responses across the analyte concentrations typically found in urine collected from daily smokers. Because matrix ion suppression may influence accuracy, we include a discussion of conventions employed in this procedure to minimize matrix interferences. Simplicity, low cost, low maintenance combined with high mean metabolite recovery (76-99%, specificity, accuracy (0-10% bias and reproducibility (2-9% C.V. make this method ideal for large high through-put studies.

  10. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  11. Determination of benzoylurea insecticides in food by pressurized liquid extraction and LC-MS.

    Science.gov (United States)

    Brutti, Monia; Blasco, Cristina; Picó, Yolanda

    2010-01-01

    A method based on pressurized liquid extraction and LC-MS/MS has been developed for determining nine benzoylureas (BUs) in fruit, vegetable, cereals, and animal products. Samples (5 g) were homogenized with diatomaceous earth and extracted in a 22 mL cell with 22 mL of ethyl acetate at 80 degrees C and 1500 psi. After solvent concentration and exchange to methanol, BUs were analyzed by LC-MS/MS using an IT mass analyzer, which achieved several transitions of precursor ions that increase selectivity providing identification. LOQs were between 0.002 and 0.01 mg/kg, which are equal or lower than maximum residue limits established by the Codex Alimentarius. Excellent linearity was achieved over a range of concentrations from 0.01 to 1 mg/kg with correlation coefficients 0.995-0.999 (n=7). Validation of the total method was performed by analyzing in quintuplicate seven different commodities (milk, eggs, meat, rice, lettuce, avocado, and lemon) at three concentration levels (0.01, 0.1, and 1 mg/kg). The recoveries ranged from 58 to 97% and the RSDs from 5 to 19% depending on the compound and the commodity. The combination of pressurized liquid extraction with LC-MS/MS provides a sensitive and selective method for the determination of BUs in food.

  12. Development and validation of a dissolution test with reversed-phase liquid chromatography analysis for rupatadine in tablet dosage forms

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Dalmora

    2010-01-01

    Full Text Available A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

  13. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  14. Determination of Glyphosate Levels in Breast Milk Samples from Germany by LC-MS/MS and GC-MS/MS

    NARCIS (Netherlands)

    Steinborn, Angelika; Alder, Lutz; Michalski, Britta; Zomer, Paul; Bendig, Paul; Martinez, Sandra Aleson; Mol, Hans G.J.; Class, Thomas J.; Costa Pinheiro, Nathalie

    2016-01-01

    This study describes the validation and application of two independent analytical methods for the determination of glyphosate in breast milk. They are based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively. For

  15. Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets.

    Science.gov (United States)

    Nguyen, Dao T-T; Guillarme, Davy; Rudaz, Serge; Veuthey, Jean-Luc

    2008-04-01

    A simple method using ultra performance LC (UPLC) coupled with UV detection was developed and validated for the determination of antituberculosis drugs in combined dosage form, i. e. isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF). Drugs were separated on a short column (2.1 mm x 50 mm) packed with 1.7 mum particles, using an elution gradient procedure. At 30 degrees C, less than 2 min was necessary for the complete separation of the three antituberculosis drugs, while the original USP method was performed in 15 min. Further improvements were obtained with the combination of UPLC and high temperature (up to 90 degrees C), namely HT-UPLC, which allows the application of higher mobile phase flow rates. Therefore, the separation of ISN, PYR and RIF was performed in less than 1 min. After validation (selectivity, trueness, precision and accuracy), both methods (UPLC and HT-UPLC) have proven suitable for the routine quality control analysis of antituberculosis drugs in combined dosage form. Additionally, a large number of samples per day can be analysed due to the short analysis times.

  16. Development and validation of a stability-indicating capillary zone electrophoretic method for the assessment of entecavir and its correlation with liquid chromatographic methods.

    Science.gov (United States)

    Dalmora, Sergio Luiz; Nogueira, Daniele Rubert; D'Avila, Felipe Bianchini; Souto, Ricardo Bizogne; Leal, Diogo Paim

    2011-01-01

    A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 µm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1-200 µg mL(-1) (r(2) = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).

  17. Untargeted LC-Q-TOF mass spectrometry method for the detection of adulterations in skimmed-milk powder

    NARCIS (Netherlands)

    Cordewener, J.H.G.; Luykx, D.M.A.M.; Frankhuizen, R.; Bremer, M.G.E.G.; Hooijerink, H.; America, A.H.P.

    2009-01-01

    A nontargeted protein identification method was developed to screen for adulterations in skimmed-milk powder (SMP). There are indications of falsified SMP content due to the addition of plant proteins. To demonstrate the reliability and accuracy of the developed comparative LC-MS method using a

  18. Data representing two separate LC-MS methods for detection and quantification of water-soluble and fat-soluble vitamins in tears and blood serum

    Directory of Open Access Journals (Sweden)

    Maryam Khaksari

    2017-04-01

    Full Text Available Two separate liquid chromatography (LC-mass spectrometry (MS methods were developed for determination and quantification of water-soluble and fat-soluble vitamins in human tear and blood serum samples. The water-soluble vitamin method was originally developed to detect vitamins B1, B2, B3 (nicotinamide, B5, B6 (pyridoxine, B7, B9 and B12 while the fat-soluble vitamin method detected vitamins A, D3, 25(OHD3, E and K1. These methods were then validated with tear and blood serum samples. In this data in brief article, we provide details on the two LC-MS methods development, methods sensitivity, as well as precision and accuracy for determination of vitamins in human tears and blood serum. These methods were then used to determine the vitamin concentrations in infant and parent samples under a clinical study which were reported in "Determination of Water-Soluble and Fat-Soluble Vitamins in Tears and Blood Serum of Infants and Parents by Liquid Chromatography/Mass Spectrometry DOI:10.1016/j.exer.2016.12.007 [1]". This article provides more details on comparison of vitamin concentrations in the samples with the ranges reported in the literature along with the medically accepted normal ranges. The details on concentrations below the limits of detection (LOD and limits of quantification (LOQ are also discussed. Vitamin concentrations were also compared and cross-correlated with clinical data and nutritional information. Significant differences and strongly correlated data were reported in [1]. This article provides comprehensive details on the data with slight differences or slight correlations.

  19. Data representing two separate LC-MS methods for detection and quantification of water-soluble and fat-soluble vitamins in tears and blood serum.

    Science.gov (United States)

    Khaksari, Maryam; Mazzoleni, Lynn R; Ruan, Chunhai; Kennedy, Robert T; Minerick, Adrienne R

    2017-04-01

    Two separate liquid chromatography (LC)-mass spectrometry (MS) methods were developed for determination and quantification of water-soluble and fat-soluble vitamins in human tear and blood serum samples. The water-soluble vitamin method was originally developed to detect vitamins B 1 , B 2 , B 3 (nicotinamide), B 5 , B 6 (pyridoxine), B 7 , B 9 and B 12 while the fat-soluble vitamin method detected vitamins A, D 3 , 25(OH)D 3, E and K 1 . These methods were then validated with tear and blood serum samples. In this data in brief article, we provide details on the two LC-MS methods development, methods sensitivity, as well as precision and accuracy for determination of vitamins in human tears and blood serum. These methods were then used to determine the vitamin concentrations in infant and parent samples under a clinical study which were reported in "Determination of Water-Soluble and Fat-Soluble Vitamins in Tears and Blood Serum of Infants and Parents by Liquid Chromatography/Mass Spectrometry DOI:10.1016/j.exer.2016.12.007 [1]". This article provides more details on comparison of vitamin concentrations in the samples with the ranges reported in the literature along with the medically accepted normal ranges. The details on concentrations below the limits of detection (LOD) and limits of quantification (LOQ) are also discussed. Vitamin concentrations were also compared and cross-correlated with clinical data and nutritional information. Significant differences and strongly correlated data were reported in [1]. This article provides comprehensive details on the data with slight differences or slight correlations.

  20. A validated LC-MS/MS method for the determination of senkyunolide I in dog plasma and its application to a pharmacokinetic and bioavailability studies.

    Science.gov (United States)

    Li, Jin-Qi; Wang, Jia-Feng; Li, Jie; Zhang, Shu-Han; He, Dan; Tong, Rong-Sheng; She, Shu-Ya

    2018-05-01

    Senkyunolide I is one of the major bioactive components in the herbal medicine Ligusticum chuanxiong. The aim of this study was to develop and validate a fast, simple and sensitive LC-MS/MS method for the determination of senkyunolide I in dog plasma. The plasma samples were processed with acetonitrile and separated on a Waters Acquity UPLC BEH C 18 column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 0.1% formic acid aqueous and acetonitrile was delivered at a flow rate of 0.3 mL min -1 . The detection was achieved in the positive selected reaction monitoring mode with precursor-to-product transitions at m/z 225.1 → 161.1 for senkyunolide I and at m/z 349.1 → 305.1 for an internal standard. The assay was linear over the tested concentration range, from 0.5 ng mL -1 to 1000 ng mL -1 , with a correlation coefficient >0.9992. The mean extraction recovery from dog plasma was within the range of 85.78-93.25%, while the matrix effect of the analyte was within the range of 98.23-108.89%. The intra- and inter-day precisions (RSD) were dogs. The results demonstrated that (a) senkyunolide I showed short elimination half-life (dog, (b) its oral bioavailability was >40% and (c) senkyunolide I showed dose-independent pharmacokinetic profiles in dog plasma over the dose range of 1-50 mg kg -1 . Copyright © 2018 John Wiley & Sons, Ltd.

  1. Development and validation of an LC-MS/MS method to quantify lysergic acid diethylamide (LSD), iso-LSD, 2-oxo-3-hydroxy-LSD, and nor-LSD and identify novel metabolites in plasma samples in a controlled clinical trial.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2018-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of this study was to develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantification of LSD, iso-LSD, 2-oxo-3-hydroxy LSD (O-H-LSD), and nor-LSD in plasma samples from 24 healthy subjects after controlled administration of 100 μg LSD in a clinical trial. In addition, metabolites that have been recently described in in vitro studies, including lysergic acid monoethylamide (LAE), lysergic acid ethyl-2-hydroxyethylamide (LEO), 2-oxo-LSD, trioxylated-LSD, and 13/14-hydroxy-LSD, should be identified. Separation of LSD and its metabolites was achieved on a reversed phase chromatography column after turbulent-flow online extraction. For the identification and quantification, a triple-stage quadrupole LC-MS/MS instrument was used. The validation data showed slight matrix effects for LSD, iso-LSD, O-H-LSD, or nor-LSD. Mean intraday and interday accuracy and precision were 105%/4.81% and 105%/4.35% for LSD, 98.7%/5.75% and 99.4%/7.21% for iso-LSD, 106%/4.54% and 99.4%/7.21% for O-H-LSD, and 107%/5.82% and 102%/5.88% for nor-LSD, respectively. The limit of quantification was 0.05 ng/mL for LSD, iso-LSD, and nor-LSD and 0.1 ng/mL for O-H-LSD. The limit of detection was 0.01 ng/mL for all compounds. The method described herein was accurate, precise, and the calibration range within the range of expected plasma concentrations. LSD was quantified in the plasma samples of the 24 subjects of the clinical trial, whereas iso-LSD, O-H-LSD, nor-LSD, LAE, LEO, 13/14-hydroxy-LSD, and 2-oxo-LSD could only sporadically be detected but were too low for quantification. © 2017 Wiley Periodicals, Inc.

  2. High-sensitive LC-MS/MS method for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma: application to microdose clinical trials of mirodenafil.

    Science.gov (United States)

    Cho, Doo-Yeoun; Bae, Soo Hyeon; Shon, Ji-Hong; Bae, Soo Kyung

    2013-03-01

    A high-sensitivity LC/MS/MS method was developed and validated for the simultaneous determination of mirodenafil and its major metabolite, SK-3541, in human plasma. Mirodenafil, SK-3541, and udenafil as an internal standard were extracted from plasma samples with methyl tert-butyl ether. Chromatographic separation was performed on a Luna phenyl-hexyl column (100 × 2.0 mm) with an isocratic mobile phase consisting of 5 mM ammonium formate and ACN (23:77, v/v) at a flow rate of 0.35 mL/min. Detection and quantification were performed using a mass spectrometer in selected reaction monitoring mode with positive ESI at m/z 532.3 → 296.1 for mirodenafil, m/z 488.1 → 296.1 for SK-3541, and m/z 517.3 → 283.2 for udenafil. The calibration curves were linear over a concentration range of 2-500 pg/mL using 0.5 mL plasma for the microdose of mirodenafil (100 μg). Analytical method validation of the clinical dose (100 mg), with a calibration curve range of 2-500 ng/mL using 0.025-mL plasma, was also conducted. The other LC-MS/MS conditions were similar to those used for the microdosing. Each method was applied successfully to pharmacokinetic studies after a microdose or clinical dose of mirodenafil to six healthy Korean male volunteers. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. What Is in Your Wallet? Quantitation of Drugs of Abuse on Paper Currency with a Rapid LC-MS/MS Method

    Science.gov (United States)

    Parker, Patrick D.; Beers, Brandon; Vergne, Matthew J.

    2017-01-01

    Laboratory experiments were developed to introduce students to the quantitation of drugs of abuse by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Undergraduate students were introduced to internal standard quantitation and the LC-MS/MS method optimization for cocaine. Cocaine extracted from paper currency was…

  4. Development of an LC-MS/MS method for the determination of pesticides and patulin in apples

    DEFF Research Database (Denmark)

    Christensen, Hanne Bjerre; Poulsen, Mette Erecius; Rasmussen, Peter Have

    2009-01-01

    A method for the simultaneous determination of 33 pesticides or degradation products together with patulin in apples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. The method involved homogenization of the apples, extraction with ammonium acetate-acetic acid solution...... in methanol-water by ultrasonication, filtration, and determination by LC-MS/MS. The repeatability and within-laboratory reproducibility for the three spiking levels 0.02, 0.04 and 0.2 mg kg(-1) were between 4% and 35%. In general, the repeatability and reproducibility were about 10-20%. The limits...... of quantification (LOQs) were between 0.01 and 0.14 mg kg(-1). The method was used on incurred samples from parts of the ISAFRUIT project financed by the European Commission under the 6th Framework Programme. Samples were analysed at four different stages: after harvest, after storage (controlled), after a water...

  5. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    Science.gov (United States)

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  6. Evaluation of a multiresidue method for measuring fourteen chemical groups of pesticides in water by use of LC-MS-MS.

    Science.gov (United States)

    Carvalho, J J; Jerónimo, P C A; Gonçalves, C; Alpendurada, M F

    2008-11-01

    European Council Directive 98/83/EC on the quality of water intended for human consumption brought a new challenge for water-quality control routine laboratories, mainly on pesticides analysis. Under the guidelines of ISO/IEC 17025:2005, a multiresidue method was developed, validated, implemented in routine, and studied with real samples during a one-year period. The proposed method enables routine laboratories to handle a large number of samples, since 28 pesticides of 14 different chemical groups can be quantitated in a single procedure. The method comprises a solid-phase extraction step and subsequent analysis by liquid chromatography-mass spectrometry (LC-MS-MS). The accuracy was established on the basis of participation in interlaboratory proficiency tests, with encouraging results (majority |z-score| <2), and the precision was consistently analysed over one year. The limits of quantitation (below 0.050 microg L(-1)) are in agreement with the enforced threshold value for pesticides of 0.10 microg L(-1). Overall method performance is suitable for routine use according to accreditation rules, taking into account the data collected over one year.

  7. Development and validation of confirmatory method for analysis of nitrofuran metabolites in milk, honey, poultry meat and fish by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Fatih Alkan

    2016-03-01

    Full Text Available In this study we have devoloped and validated a confirmatory analysis method for nitrofuran metabolites, which is in accordance with European Commission Decision 2002/657/EC requirements. Nitrofuran metabolites in honey, milk, poultry meat and fish samples were acidic hydrolised followed by derivatisation with nitrobenzaldehyde and liquid-liquid extracted with ethylacetate. The quantitative and confirmative determination of nitrofuran metbolites was performed by liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI-MS/MS in the positive ion mode. In-house method validation was performed and reported data of validation (specificity, linearity, recovery, CCα and CCβ. The advantage of this method is that it avoids the use of clean-up by Solid-Phase Extraction (SPE. Furthermore, low levels of nitrofuran metabolites are detectable and quantitatively confirmed at a rapid rate in all samples.

  8. Establishment of a method for determination of arsenic species in seafood by LC-ICP-MS.

    Science.gov (United States)

    Zmozinski, Ariane V; Llorente-Mirandes, Toni; López-Sánchez, José F; da Silva, Márcia M

    2015-04-15

    An analytical method for determination of arsenic species (inorganic arsenic (iAs), methylarsonic acid (MA), dimethylarsinic acid (DMA), arsenobetaine (AB), trimethylarsine oxide (TMAO) and arsenocholine (AC)) in Brazilian and Spanish seafood samples is reported. This study was focused on extraction and quantification of inorganic arsenic (iAs), the most toxic form. Arsenic speciation was carried out via LC with both anionic and cationic exchange with ICP-MS detection (LC-ICP-MS). The detection limits (LODs), quantification limits (LOQs), precision and accuracy for arsenic species were established. The proposed method was evaluated using eight reference materials (RMs). Arsenobetaine was the main species found in all samples. The total and iAs concentration in 22 seafood samples and RMs ranged between 0.27-35.2 and 0.02-0.71 mg As kg(-1), respectively. Recoveries ranging from 100% to 106% for iAs, based on spikes, were achieved. The proposed method provides reliable iAs data for future risk assessment analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Comparison of conventional liquid chromatography-tandem mass spectrometry versus microflow liquid chromatography-tandem mass spectrometry within the framework of full method validation for simultaneous quantification of 40 antidepressants and neuroleptics in whole blood.

    Science.gov (United States)

    Steuer, Andrea E; Poetzsch, Michael; Koenig, Magdalena; Tingelhoff, Eva; Staeheli, Sandra N; Roemmelt, Andreas T; Kraemer, Thomas

    2015-02-13

    Microflow liquid chromatography (MFLC) coupled to mass spectrometry (MS) is claimed to improve analysis throughput, reduce matrix effects and lower mobile phase consumption. This statement was checked within the framework of method validation of a multi-analyte procedure in clinical and forensic toxicology employing MFLC-MS/MS and conventional LC-MS/MS. 200 μL whole blood were spiked with 50 μL internal standard mixture and extracted by protein precipitation. The concentrated extract was separated into two vials. One was analyzed using a Thermo Fisher Ultimate liquid chromatography system coupled to an ABSciex 5500 QTrap mass spectrometer (LC-MS/MS) and one by an ABSciex Eksigent Microflow LC system coupled to an ABSciex 4500 linear ion trap quadrupole MS (MFLC-MS/MS). Both methods were fully validated and compared in terms of selectivity, stability, limits, calibration model, recovery (RE), matrix effects (ME), bias, imprecision and beta tolerance interval for 40 antidepressants and neuroleptics including 9 metabolites. Both methods had comparable LODs, LOQs and calibration models with some exceptions. The MFLC system showed slightly higher coefficients of variation (CVs) in the RE experiments. ME were reproducible in both systems but with lower CVs in the conventional LC system. Acceptance criteria for imprecision and bias were fulfilled for 32 analytes on the LC and for 28 analytes on the MFLC system. Beta tolerance intervals indicated better reproducibility in terms of narrower intervals for the conventional LC system. The advantages of the MFLC system were low mobile phase consumption, short run time, and better peak separation. The systems were comparable in terms of peak interference, LOD, ME, bias and imprecision. The advantages of the conventional LC system were more data points per peak, linear calibration models, stable retention times and better beta tolerance intervals. Due to higher robustness, the conventional LC system was finally chosen for

  10. The simultaneous detection and quantification of p-aminobenzoic acid and its phase 2 biotransformation metabolites in human urine using LC-MS/MS.

    Science.gov (United States)

    Nortje, Carla; Jansen van Rensburg, Peet; Cooke, Cecile; Erasmus, Elardus

    2015-01-01

    p-Aminobenzoic acid (PABA) can be used as a probe substance to investigate glycine conjugation, a reaction of phase 2 biotransformation. An LC-MS/MS method for simultaneous quantification of PABA and its metabolites from human urine was developed and validated. The metabolites can be quantified with acceptable precision and accuracy directly from human urine samples after ingestion of 550 mg PABA. The developed LC-MS/MS assay is to our knowledge the first method available for the simultaneous quantification of PABA and its glycine conjugation metabolites in human urine and provides important quantitative data for studies of this phase 2 biotransformation pathway.

  11. Comparative studies of HPLC-fluorometry and LC/MS method for the determination of N-acetylneuraminic acid as a marker of deteriorated ophthalmic solutions.

    Science.gov (United States)

    Iwatsuka, Kinya; Yasueda, Shin-ichi; Bando, Eiji; Fujii, Hiroyuki; Terada, Takashi; Okubo, Hiroya; Iwamoto, Hiroki; Kinoshita, Mitsuhiro; Kakehi, Kazuaki

    2011-10-01

    Methods for determining the deterioration of ophthalmic solutions using both high-performance liquid chromatography (HPLC) with fluorescence detection and liquid chromatography coupled with selected ion monitoring mass spectrometry (LC/MS) are described. The methods are based on the determination of N-acetylneuraminic acid (NeuAc) released by the hydrolysis of foreign bodies that contaminate eye drops during use. The released NeuAc was either labeled with 1,2-diamino-4,5-methylenedioxybenzene (DMB) for fluorometric detection or detected without derivatization by mass spectrometry. The calibration curves for NeuAc showed good linearity between 1.2 ng/mL and 39 ng/mL for fluorometric HPLC and 5.0 ng/mL and 100 ng/mL for LC/MS, respectively. Detection limits for fluorometric HPLC and LC/MS were 0.20 ng/mL and 0.88 ng/mL, respectively. The NeuAc content of some model glycoproteins determined by LC/MS method were 62-78% of those determined by fluorometry. The differences are attributed to matrix effects but the LC/MS method afforded sufficiently high sensitivity that NeuAc in the foreign bodies could be determined in eight of nine test samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. RP-HPLC Method Development and Validation for the Determination and Stability Indicative Studies of Montelukast in Bulk and its Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    A. Patnaik

    2012-01-01

    Full Text Available A simple, precise, accurate, economical and reproducible HPLC method for estimation of montelukast in tablet dosage form has been developed. Quantitative HPLC was performed with Shimadzu LC2010c HT with Winchrom Software with UV-Visible detector (SPD-IOA, PUMP (LC-IOAT and (LC-IOATvp. Phenomenex C8, 5 μm, 25 cm × 4.6 mm i.d. column was used in the study. The mobile phase of ACN: Acetate buffer= 6.5:3.5 of pH 3 were used in this study. The conditions optimized were: flow rate (1 mL/minute, wavelength (222 nm and run time was 20 min. Retention time was found to be 3.08 min. The linearity was found to be in the concentration range of 10-100 μg/mL. The developed method was evaluated in the assay of commercially available tablet moni containing 10 mg of montelukast. The amount of drug in tablet was found to be 10.34 mg/tab for the brand. Results of analysis were validated statistically and by recovery studies. The recovery studies 99.67% was indicative of the accuracy of proposed method. The precision was calculated as repeatability, inter and intraday variation (%RSD for the drug. By using the method, stability of the drug has been studied.

  13. Simultaneous determination and validation of emtricitabine, rilpivirine and tenofovir from biological samples using LC and CE methods.

    Science.gov (United States)

    Gumustas, Mehmet; Caglayan, Mehmet Gokhan; Onur, Feyyaz; Ozkan, Sibel A

    2018-04-01

    A combination of antiretroviral agents is frequently used in effective treatment of the human immunodeficiency virus infection. In this study, two different separation methods are presented for the simultaneous determination of emtricitabine, rilpivirine and tenofovir from raw materials and urine samples. Developed liquid chromatography and capillary electrophoresis methods were thoroughly optimized for high analytical performances. Optimization of multiple variables at the same time by performing a minimum number of experiments was achieved by the Box-Behnken design, which is an experimental design in response surface methodology, in capillary electrophoresis. The results of the experimental design ensure minimum analysis time with well-separated analytes. Separation conditions, such as different stationary phases, pH level, organic modifiers and temperatures in liquid chromatography method, were also optimized. In particular, among stationary phases, the core-shell column especially enhanced the effectiveness of separation in liquid chromatography. Both methods were fully validated and applied to real samples. The main advantage of the developed methods is the separation of the drug combination in a short time with high efficiency and without any time-consuming steps. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Validation of QuEChERS method for the determination of some pesticide residues in two apple varieties.

    Science.gov (United States)

    Tiryaki, Osman

    2016-10-02

    This study was undertaken to validate the "quick, easy, cheap, effective, rugged and safe" (QuEChERS) method using Golden Delicious and Starking Delicious apple matrices spiked at 0.1 maximum residue limit (MRL), 1.0 MRL and 10 MRL levels of the four pesticides (chlorpyrifos, dimethoate, indoxacarb and imidacloprid). For the extraction and cleanup, original QuEChERS method was followed, then the samples were subjected to liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) for chromatographic analyses. According to t test, matrix effect was not significant for chlorpyrifos in both sample matrices, but it was significant for dimethoate, indoxacarb and imidacloprid in both sample matrices. Thus, matrix-matched calibration (MC) was used to compensate matrix effect and quantifications were carried out by using MC. The overall recovery of the method was 90.15% with a relative standard deviation of 13.27% (n = 330). Estimated method detection limit of analytes blew the MRLs. Some other parameters of the method validation, such as recovery, precision, accuracy and linearity were found to be within the required ranges.

  15. Analysis of membrane proteome by data-dependent LC-MS/MS combined with data-independent LC-MSE technique

    Directory of Open Access Journals (Sweden)

    Joseph Kwon

    2010-03-01

    Full Text Available Proteomics work resembles the search for a needle in a haystack. The identification of protein biomarker requires the removal of the false protein data from the whole protein mixture. For high quality proteomic data, even a strict filtration step using the false discovery rate (FDR is insufficient for obtaining perfect protein information from the biological samples. In this study, the cyanobacterial whole membrane fraction was applied to the data-dependent analysis (DDA mode of LC-MS/MS, which was used along with the data-independent LC-MSE technique in order to evaluate the membrane proteomic data. Furthermore, the identified MSE-information (MSE-i data based on the peptide mass and the retention time were validated by the other database search, i.e., the probability-based MASCOT and de novo search engine PEAKS. In this present study, 208 cyanobacterial proteins with FDR of 5% were identified using the data-independent nano-UPLC/MSE acquisition with the Protein Lynx Global Server (PLGS, and 56 of these proteins were the predicted membrane proteins. When a total of 208 MSE-i proteomic data were applied to the DDA mode of LC-MS/MS, the number of identified membrane proteins was 26 and 33 from MASCOT and PEAKS with a FDR of 5%, respectively. The number of totally overlapped membrane proteins was 25. Therefore, the data-independent LC-MSE identified more proteins with a high confidence.

  16. LC-MS-based quantification method for Achyranthes root saponins.

    Science.gov (United States)

    Kawahara, Yuki; Hoshino, Tatsuro; Morimoto, Hidetaka; Shinizu, Tomofumi; Narukawa, Yuji; Fuchino, Hiroyuki; Kawahara, Nobuo; Kiuchi, Fumiyuki

    2016-01-01

    A liquid chromatography mass spectrometry (LC-MS) method was developed for simultaneous quantitative analysis of Achyranthes root saponins: chikusetsusaponins IVa (1) and V (2), achyranthosides B (3), C (4), D (5), E (6), and G (7), sulfachyranthosides B (8) and D (9), and betavulgarosides II (10) and IV (11). Satisfactory separation of the saponins was achieved with the use of a volatile ion-pair reagent (dihexyl ammonium acetate) on a phenyl-hexylated silica gel column, and the amounts of saponins extracted under three different conditions were determined. When Achyranthes root was extracted with water at room temperature, achyranthosides B (3) and D (5) were the major saponins, and smaller amounts of other saponins (4, 6-11) were present. However, the amounts of chikusetsusaponins (1 and 2) were negligible. Under the condition to make a standard decoction of a Kampo formula, the major saponins were achyranthosides B (3), C (4), and D (5), and small amounts of chikusetsusaponins IVa (1) and V (2) appeared, whereas prolonged heating largely increased the amounts of chikusetsusaponins. This method can be used for quality control of Achyranthes root.

  17. Synthesis and Characterization of Maillard Reaction Products of Salbutamol and Terbutaline with Lactose and Development and Validation of an LC Method for the Determination of Salbutamol and Terbutaline in the Presence of These Impurities

    Directory of Open Access Journals (Sweden)

    Asmaa A. El-Zaher

    2014-01-01

    Full Text Available Being secondary amines, both salbutamol (SLB and terbutaline (TRB react by Maillard reaction (MR with lactose, which is added as an inactive ingredient in tablets. The Amadori rearrangement products were synthesized, isolated, and characterized by mass spectrometry. In addition, a simple, selective, and precise reversed-phase liquid chromatography (LC method was developed and validated for the determination of SLB and TRB in tablets, each in the presence of its MR impurity. The chromatographic separation was performed on a Symmetry® Waters C18 column (150 mm × 4.6 mm, 5 μm using a mobile phase consisting of 0.5% aqueous phosphoric acid to acetonitrile (90:10, v/v at a flow rate of 0.7 mL minute −1 . Quantitation was achieved using UV detection at 230 nm. Linearity, accuracy, and precision were found to be acceptable for the determination of SLB and TRB in the concentration range of 0.2-60 and 0.5-80 μg mL −1 , respectively. The proposed method was successfully applied to the determination of SLB and TRB in bulk and in their tablets.

  18. A validated stability-indicating RP-HPLC method for levofloxacin in the presence of degradation products, its process related impurities and identification of oxidative degradant.

    Science.gov (United States)

    Lalitha Devi, M; Chandrasekhar, K B

    2009-12-05

    The objective of current study was to develop a validated specific stability indicating reversed-phase liquid chromatographic method for the quantitative determination of levofloxacin as well as its related substances determination in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its process related impurities. Forced degradation studies were performed on bulk sample of levofloxacin as per ICH prescribed stress conditions using acid, base, oxidative, water hydrolysis, thermal stress and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during oxidative stress and the degradation product formed was identified by LCMS/MS, slight degradation in acidic stress and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked solution. Good resolution between the peaks corresponds to process related impurities and degradation products from the analyte were achieved on ACE C18 column using the mobile phase consists a mixture of 0.5% (v/v) triethyl amine in sodium dihydrogen orthophosphate dihydrate (25 mM; pH 6.0) and methanol using a simple linear gradient. The detection was carried out at 294 nm. The limit of detection and the limit of quantitation for the levofloxacin and its process related impurities were established. The stressed test solutions were assayed against the qualified working standard of levofloxacin and the mass balance in each case was in between 99.4 and 99.8% indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of levofloxacin at the time of batch release and also during its stability studies (long term and accelerated stability).

  19. Development, validation and clinical application of a method for the simultaneous quantification of lamivudine, emtricitabine and tenofovir in dried blood and dried breast milk spots using LC-MS/MS.

    Science.gov (United States)

    Waitt, Catriona; Diliiy Penchala, Sujan; Olagunju, Adeniyi; Amara, Alieu; Else, Laura; Lamorde, Mohammed; Khoo, Saye

    2017-08-15

    To present the validation and clinical application of a LC-MS/MS method for the quantification of lamivudine (3TC), emtricitabine (FTC) and tenofovir (TFV) in dried blood spots (DBS) and dried breast milk spots (DBMS). DBS and DBMS were prepared from 50 and 30μL of drug-spiked whole blood and human breast milk, respectively. Following extraction with acetonitrile and water, chromatographic separation utilised a Synergi polar column with a gradient mobile phase program consisting of 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Detection and quantification was performed using a TSQ Quantum Ultra triple quadrupole mass spectrometer. The analytical method was used to evaluate NRTI drug levels in HIV-positive nursing mothers-infant pairs. The assay was validated over the concentration range of 16.6-5000ng/mL for 3TC, FTC and TFV in DBS and DBMS except for TFV in DBMS where linearity was established from 4.2-1250ng/mL. Intra and inter-day precision (%CV) ranged from 3.5-8.7 and accuracy was within 15% for all analytes in both matrices. The mean recovery in DBS was >61% and in DBMS >43% for all three analytes. Matrix effect was insignificant. Median AUC 0-8 values in maternal DBS and DBMS, respectively, were 4683 (4165-6057) and 6050 (5217-6417)ngh/mL for 3TC, 3312 (2259-4312) and 4853 (4124-6691)ngh/mL for FTC and 1559 (930-1915) and 56 (45-80)ngh/mL for TFV. 3TC and FTC were quantifiable (>16.6ng/mL) in DBS from 2/6 and 1/6 infants respectively whereas TFV was undetectable in all infants. DBS and DBMS sampling for bioanalysis of 3TC, FTC and TFV is straightforward, robust, accurate and precise, and ideal for use in low-resource settings. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. An Automatic Parameter Identification Method for a PMSM Drive with LC-Filter

    DEFF Research Database (Denmark)

    Bech, Michael Møller; Christensen, Jeppe Haals; Weber, Magnus L.

    2016-01-01

    of the PMSM fed through an LC-filter. Based on the measured current response, model parameters for both the filter (L, R, C) and the PMSM (L and R) are estimated: First, the frequency response of the system is estimated using Welch Modified Periodogram method and then an optimization algorithm is used to find...... the parameters in an analytical reference model that minimize the model error. To demonstrate the practical feasibility of the method, a fully functional drive including an embedded real-time controller has been built. In addition to modulation, data acquisition and control the whole parameter identification...... method is also implemented on the real-time controller. Based on laboratory experiments on a 22 kW drive, it is concluded that the embedded identification method can estimate the five parameters in less than ten seconds....

  1. Ferro-based derivatizing agents for LC/MS an LC/EC/MS

    NARCIS (Netherlands)

    Seiwert, Bettina

    2007-01-01

    Within this thesis, the development and application of ferrocene-based derivatizing agents for LC/MS and LC/EC/MS is presented. The advantages of derivatization by ferrocenes are the similtaneous introduction of a mass tag and an electroactive group, which make them ideally suited for LC/MS and

  2. Vigabatrin in dried plasma spots: validation of a novel LC-MS/MS method and application to clinical practice.

    Science.gov (United States)

    Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana

    2014-07-01

    This paper presents a LC-MS/MS method for the determination of antiepileptic drug vigabatrin in dried plasma spots (DPS). Due to its zwitterionic chemical structure, a pre-column derivatization procedure was performed, aiming to yield enhanced ionization efficiency and improved chromatographic behaviour. Propyl chloroformate, in the presence of propanol, was selected as the best derivatization reagent, providing a strong signal along with reasonable run time. A relatively novel sample collection technique, DPS, was utilized, offering easy sample handling and analysis, using a sample in micro amount (∼5μL). Derivatized vigabatrin and its internal standard, 4-aminocyclohexanecarboxylic acid, were extracted by liquid-liquid extraction (LLE) and determined in positive ion mode by applying two SRM transitions per analyte. A Zorbax Eclipse XDB-C8 column (150×4.6mm, 5μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 4.5min. The assay exhibited excellent linearity over the concentration range of 0.500-50.0μg/mL, which is suitable for the determination of vigabatrin level after per os administration in children and youths with epilepsy, who were on vigabatrin therapy, with or without co-medication. Specificity, accuracy, precision, recovery, matrix-effect and stability were also estimated and assessed within acceptance criteria. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A General LC-MS/MS Method for Monitoring Potential β-Lactam Contamination in Drugs and Drug-Manufacturing Surfaces.

    Science.gov (United States)

    Qiu, Chen; Zhu, Hongbin; Ruzicka, Connie; Keire, David; Ye, Hongping

    2018-05-15

    Penicillins and some non-penicillin β-lactams may cause potentially life-threatening allergic reactions. Thus, possible cross contamination of β-lactams in food or drugs can put people at risk. Therefore, when there is a reasonable possibility that a non-penicillin product could be contaminated by penicillin, the drug products are tested for penicillin contamination. Here, a sensitive and rapid method for simultaneous determination of multiple β-lactam antibiotics using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated. Mass spectral acquisition was performed on a Q-Exactive HF mass spectrometer in positive ion mode with parallel reaction monitoring (PRM). The method was validated for seven β-lactam antibiotics including one or two from each class and a synthetic intermediate. The quantification precision and accuracy at 200 ppb were in the range of ± 1.84 to ± 4.56 and - 5.20 to 3.44%, respectively. The limit of detection (LOD) was 0.2 ppb, and the limit of quantitation (LOQ) was 2 ppb with a linear dynamic range (LDR) of 2-2000 ppb for all eight β-lactams. From various drug products, the recoveries of eight β-lactams at 200 and 2 ppb ranged from 93.8 ± 3.2 to 112.1 ± 4.2% and 89.7 ± 4.6 to 110.6 ± 1.9%, respectively. The application of the method for detecting cross contamination of trace β-lactams (0.2 ppb) and for monitoring facility surface cleaning was also investigated. This sensitive and fast method was fit-for-purpose for detecting and quantifying trace amount of β-lactam contamination, monitoring cross contamination in manufacturing processes, and determining potency for regulatory purposes and for quality control.

  4. Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS.

    Science.gov (United States)

    Lopez, Mayda I; Pettis, Jeffery S; Smith, I Barton; Chu, Pak-Sin

    2008-03-12

    A multiclass method has been developed for the determination and confirmation in honey of tetracyclines (chlortetracycline, doxycycline, oxytetracycline, and tetracycline), fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, and sarafloxacin), macrolides (tylosin), lincosamides (lincomycin), aminoglycosides (streptomycin), sulfonamides (sulfathiazole), phenicols (chloramphenicol), and fumagillin residues using liquid chromatography tandem mass spectrometry (LC-MS/MS). Erythromycin (a macrolide) and monensin (an ionophore) can be detected and confirmed but not quantitated. Honey samples (approximately 2 g) are dissolved in 10 mL of water and centrifuged. An aliquot of the supernatant is used to determine streptomycin. The remaining supernatant is filtered through a fine-mesh nylon fabric and cleaned up by solid phase extraction. After solvent evaporation and sample reconstitution, 15 antibiotics are assayed by LC-MS/MS using electrospray ionization (ESI) in positive ion mode. Afterward, chloramphenicol is assayed using ESI in negative ion mode. The method has been validated at the low part per billion levels for most of the drugs with accuracies between 65 and 104% and coefficients of variation less than 17%. The evaluation of matrix effects caused by honey of different floral origin is presented.

  5. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City, 300001 Nigeria. All rights reserved. Available online at http://www.tjpr.org ... dihydrochloride in solid dosage forms. Methods: Chromatographic separation was achieved on Grace Smart C18 column (250 × 4.6 mm, 5 μm) using an isocratic mobile ...

  6. Determination of perfluorinated compounds in fish fillet homogenates: Method validation and application to fillet homogenates from the Mississippi River

    International Nuclear Information System (INIS)

    Malinsky, Michelle Duval; Jacoby, Cliffton B.; Reagen, William K.

    2011-01-01

    We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100 ± 13% with a precision (%RSD) ≤18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented.

  7. Determination of perfluorinated compounds in fish fillet homogenates: Method validation and application to fillet homogenates from the Mississippi River

    Energy Technology Data Exchange (ETDEWEB)

    Malinsky, Michelle Duval, E-mail: mmalinsky@mmm.com [3M Environmental Laboratory, 3M Center, Building 0260-05-N-17, St. Paul, MN 55144-1000 (United States); Jacoby, Cliffton B.; Reagen, William K. [3M Environmental Laboratory, 3M Center, Building 0260-05-N-17, St. Paul, MN 55144-1000 (United States)

    2011-01-10

    We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100 {+-} 13% with a precision (%RSD) {<=}18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented.

  8. Comparison of 7 Published LC-MS/MS Methods for the Simultaneous Measurement of Testosterone, Androstenedione, and Dehydroepiandrosterone in Serum

    DEFF Research Database (Denmark)

    Büttler, Rahel M; Martens, Frans; Fanelli, Flaminia

    2015-01-01

    , and dehydroepiandrosterone (DHEA). METHODS: We used 7 published LC-MS/MS methods to analyze in duplicate 55 random samples from both men and women. We performed Passing-Bablok regression analysis and calculated Pearson correlation coefficients to assess the agreement of the methods investigated with the median concentration...

  9. Optimization and validation of a new method of analysis for polycyclic aromatic hydrocarbons in sewage sludge by liquid chromatography after microwave assisted extraction

    International Nuclear Information System (INIS)

    Villar, P.; Callejon, M.; Alonso, E.; Jimenez, J.C.; Guiraum, A.

    2004-01-01

    Characterization of sludge from waste water treatment plants which are destined to be spread on agricultural lands, is a priority need. Inorganic pollutants are regularly controlled but organic pollutants have received little attention up to now. In this paper, we have developed an analytical procedure using microwave-assisted extraction prior to liquid chromatography coupled with diode array (LC-DAD) or fluorescence (LC-FL) detectors for the determination of polycyclic aromatic hydrocarbons (PAHs) in sewage sludge. The main factors affecting the extraction efficiency (microwave power, irradiation time and extractant volume) were optimized. Clean-up of sewage sludge extracts was not found to be necessary. For adequate fluorescence detection of PAHs a temporal program of excitation and emission wavelengths was used. The optimized method was applied to the extraction of PAHs from various sludges from a waste water treatment plant (Jerez de la Frontera, Cadiz, Spain). The limits of detection were between 4 ng g -1 sewage sludge for benzo[b]fluoranthene and 12 ng g -1 sewage sludge for pyrene using LC-FL. When LC-DAD is used the limits of detection were between 13 ng g -1 for indeno[1,2,3-cd]pyrene and 62 ng g -1 for naphthalene. The relative standard deviations were found to be <10%. The validation of the proposed method was carried out by application to analysis for PAHs in a certified reference material (CRM) 088 dried sewage sludge of the Community Bureau of Reference (BCR). The recoveries were between 69% for benzo[k]fluoranthene and 110% for pyrene using LC-FL and between 52% for indeno[1,2,3-cd]pyrene and 104% for benzo[a]pyrene using LC-DAD of the certified values. These results are in a very good agreement with those given in the literature

  10. Analysis of U-47700, a Novel Synthetic Opioid, in Human Urine by LC-MS-MS and LC-QToF.

    Science.gov (United States)

    Fleming, Steven W; Cooley, Justin C; Johnson, Leonard; Frazee, C Clinton; Domanski, Kristina; Kleinschmidt, Kurt; Garg, Uttam

    2017-04-01

    The illicit drug market has rapidly evolved from synthetic cannabinoids to cathinone derivatives and now a new emerging threat of synthetic opioids. These compounds were mostly developed by pharmaceutical companies during drug discovery. The new psychoactive substances are not routinely covered in drug screening and may go undetected. Recently fentanyl analogous, AH-7921, MT-45 and now U-47700 have been encountered in clinical and forensic casework. U-47700 is gaining popularity on drug user forms as a legal alternative to heroin. It is a µ-receptor agonist that is part of the trans-1-2-diamine opioid analgesic drug class developed by The Upjohn Company in an attempt to develop a non-addicting analgesic. A LC-MS-MS method was developed and validated to detect and quantify U-47700. Additional analysis was conducted with an LC-QToF to identify the presence of the parent drug and metabolites. A total of four cases have been evaluated by the LC-MS-MS methodology which has an analytical range of 1-1,250 ng/mL and limit of detection of 1 ng/mL. The concentration of U-47700 in urine specimens ranged from below the limit of quantification to 224 ng/mL. The ToF analysis detected the presence of suspected phase I demethylated metabolites that may assist future analysis of this compound. The prevalence of designer opioids in casework highlights the importance of analysis for new psychoactive substances. Traditional opiates/opioids were not detected in the presented cases, but the available case histories revealed an opioid toxidrome. These findings suggest that U-47700 drug may cause significant morbidity and mortality within the United States as an emerging drug threat. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Development of a LC-MS/MS Method for the Multi-Mycotoxin Determination in Composite Cereal-Based Samples

    Directory of Open Access Journals (Sweden)

    Barbara De Santis

    2017-05-01

    Full Text Available The analytical scenario for determining contaminants in the food and feed sector is constantly prompted by the progress and improvement of knowledge and expertise of researchers and by the technical innovation of the instrumentation available. Mycotoxins are agricultural contaminants of fungal origin occurring at all latitudes worldwide and being characterized by acute and chronic effects on human health and animal wellness, depending on the species sensitivity. The major mycotoxins of food concern are aflatoxin B1 and ochratoxin A, the first for its toxicity, and the second for its recurrent occurrence. However, the European legislation sets maximum limits for mycotoxins, such as aflatoxin B1, ochratoxin A, deoxynivalenol, fumonisins, and zearalenone, and indicative limits for T-2 and HT-2 toxins. Due to the actual probability that co-occurring mycotoxins are present in a food or feed product, nowadays, the availability of reliable, sensitive, and versatile multi-mycotoxin methods is assuming a relevant importance. Due to the wide range of matrices susceptible to mycotoxin contamination and the possible co-occurrence, a multi-mycotoxin and multi-matrix method was validated in liquid chromatography-tandem mass spectrometry (LC-MS/MS with the purpose to overcome specific matrix effects and analyze complex cereal-based samples within the Italian Total Diet Study project.

  12. Autophagosome Proteins LC3A, LC3B and LC3C Have Distinct Subcellular Distribution Kinetics and Expression in Cancer Cell Lines.

    Directory of Open Access Journals (Sweden)

    Michael I Koukourakis

    Full Text Available LC3s (MAP1-LC3A, B and C are structural proteins of autophagosomal membranes, widely used as biomarkers of autophagy. Whether these three LC3 proteins have a similar biological role in autophagy remains obscure. We examine in parallel the subcellular expression patterns of the three LC3 proteins in a panel of human cancer cell lines, as well as in normal MRC5 fibroblasts and HUVEC, using confocal microscopy and western blot analysis of cell fractions. In the cytoplasm, there was a minimal co-localization between LC3A, B and C staining, suggesting that the relevant autophagosomes are formed by only one out of the three LC3 proteins. LC3A showed a perinuclear and nuclear localization, while LC3B was equally distributed throughout the cytoplasm and localized in the nucleolar regions. LC3C was located in the cytoplasm and strongly in the nuclei (excluding nucleoli, where it extensively co-localized with the LC3A and the Beclin-1 autophagy initiating protein. Beclin 1 is known to contain a nuclear trafficking signal. Blocking nuclear export function by Leptomycin B resulted in nuclear accumulation of all LC3 and Beclin-1 proteins, while Ivermectin that blocks nuclear import showed reduction of accumulation, but not in all cell lines. Since endogenous LC3 proteins are used as major markers of autophagy in clinical studies and cell lines, it is essential to check the specificity of the antibodies used, as the kinetics of these molecules are not identical and may have distinct biological roles. The distinct subcellular expression patterns of LC3s provide a basis for further studies.

  13. Analysis of forchlorfenuron in vegetables by LC/TOF-MS after extraction with the buffered QuEChERS method.

    Science.gov (United States)

    Valverde, Antonio; Aguilera, Ana; Ferrer, Carmen; Camacho, Francisco; Cammarano, Anita

    2010-03-10

    This paper describes the application of liquid chromatography time-of-flight mass spectrometry (LC/TOF-MS), with electrospray ionization, for residue analysis of forchlorfenuron in tomato, zucchini and watermelon. The assessed method includes a sample preparation step based on the buffered QuEChERS approach. The TOF-MS fragmentation pattern of forchlorfenuron was studied at different fragmention voltages in the range of 120-270 V. Analyses were carried out under full-scan conditions by using the extracted ion chromatogram (XIC) of the m/z 248 ion with a 0.2 Da window. The linearity of the analytical response across the studied range of concentrations (10-500 microg/kg) was excellent, obtaining correlation coefficients higher than 0.999, and relative standard deviations of the response factors lower than 14%, for the 15 linear calibration curves of forchlorfenuron evaluated along the complete validation study. No significant matrix effects were observed. The signal-to-noise ratios obtained for the 10 microg/kg forchlorfenuron in matrix matched standards were >70 for all three matrices. Recovery studies were carried out on spiked tomato, zucchini and watermelon blank samples, at three concentration levels (10, 50, and 200 microg/kg) performing five replicates at each level. Forchlorfenuron mean recoveries ranged between 80% and 87% in watermelon and zucchini, and between 65% and 71% in tomato, obtaining in all cases relative standard deviation values lower than 10%. The method readily achieved a lowest validated level of 10 microg/kg, which was fit-for-purpose in residue monitoring applications.

  14. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Development and validation of a LC-MS/MS method for assessment of an anti-inflammatory indolinone derivative by in vitro blood-brain barrier models.

    Science.gov (United States)

    Jähne, Evelyn A; Eigenmann, Daniela E; Culot, Maxime; Cecchelli, Roméo; Walter, Fruzsina R; Deli, Mária A; Tremmel, Robin; Fricker, Gert; Smiesko, Martin; Hamburger, Matthias; Oufir, Mouhssin

    2014-09-01

    The compound (E,Z)-3-(4-hydroxy-3,5-dimethoxybenzylidene)indolin-2-one (indolinone) was identified from lipophilic woad extracts (Isatis tinctoria L., Brassicaceae) as a compound possessing potent histamine release inhibitory and anti-inflammatory properties [1]. To further evaluate the potential of indolinone in terms of crossing the blood-brain barrier (BBB), we screened the compound in several in vitro cell-based human and animal BBB models. Therefore, we developed a quantitative LC-MS/MS method for the compound in modified Ringer HEPES buffer (RHB) and validated it according to FDA and EMA guidelines [2,3]. The calibration curve of indolinone in the range between 30.0 and 3000ng/ml was quadratic, and the limit of quantification was 30.0ng/ml. Dilution of samples up to 100-fold did not affect precision and accuracy. The carry-over was within acceptance criteria. Indolinone proved to be stable in RHB for 3h at room temperature (RT), and for three successive freeze/thaw cycles. The processed samples could be stored in the autosampler at 10°C for at least 28h. Moreover, indolinone was stable for at least 16 days in RHB when stored below -65°C. This validation study demonstrates that our method is specific, selective, precise, accurate, and capable to produce reliable results. In the immortalized human BBB mono-culture model, the apparent permeability coefficient from apical to basolateral (PappA→B), and the Papp from basolateral to apical (PappB→A) were 19.2±0.485×10(-6)cm/s and 21.7±0.326×10(-6)cm/s, respectively. For the primary rat/bovine BBB co-culture model a PappA→B of 27.1±1.67×10(-6)cm/s was determined. In the primary rat BBB triple co-culture model, the PappA→B and the PappB→A were 56.2±3.63×10(-6)cm/s and 34.6±1.41×10(-6)cm/s, respectively. The data obtained with the different models showed good correlation and were indicative of a high BBB permeation potential of indolinone confirmed by in silico prediction calculations. P

  16. Development of SPME-LC-MS method for screening of eight beta-blockers and bronchodilators in plasma and urine samples.

    Science.gov (United States)

    Goryński, Krzysztof; Kiedrowicz, Alicja; Bojko, Barbara

    2016-08-05

    The current work describes the development and validation of a simple, efficient, and fast method using solid phase microextraction coupled to liquid chromatography-tandem mass spectrometry (SPME-LC-MS/MS) for the concomitant measurement of eight beta-blockers and bronchodilators in plasma and urine. The presented assay enables quantitative determination of acebutolol, atenolol, fenoterol, nadolol, pindolol, procaterol, sotalol, and timolol. In this work, samples were prepared on a high-throughput platform using the 96-well plate format of the thin film solid phase microextraction (TFME) system, and a biocompatible extraction phase made of hydrophilic-lipophilic balance particles. Analytes were separated on a pentafluorophenyl column (100mm×2.1mm, 3μm) by gradient elution using an UPLC Nexera coupled with an LCMS-8060 mass spectrometer. The mobile phase consisted of water-acetonitrile (0.1% formic acid) at a flow rate of 0.4mLmin(-1). The linearity of the method was checked within therapeutic blood-plasma concentrations, and shown to adequately reflect typically expected concentrations of future study samples. Post-extraction addition experiments showed that the matrix effect ranged in plasma from 98% for procaterol to 115% for nadolol, and in urine, from 85% for nadolol and pindolol to 119% for atenolol. The method was successfully validated using Food and Drug Administration (FDA) guidelines, and met all acceptance criteria for bioanalytical assays at five concentration levels for all selected drugs. The final protocol can be successfully applied for monitoring concentrations of the selected drugs in both plasma and urine matrices obtained from patients or athletes. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Antioxidant activity of leaf extracts from different Hibiscus sabdariffa accessions and simultaneous determination five major antioxidant compounds by LC-Q-TOF-MS.

    Science.gov (United States)

    Wang, Jin; Cao, Xianshuang; Jiang, Hao; Qi, Yadong; Chin, Kit L; Yue, Yongde

    2014-12-17

    Hibiscus sabdariffa has gained attention for its antioxidant activity. There are many accessions of H. sabdariffa in the world. However, information on the quantification of antioxidant compounds in different accessions is rather limited. In this paper, a liquid chromatography/quadrupole-time-of-flight mass spectrometry (LC-Q-TOF-MS) method for simultaneous determination of five antioxidant compounds (neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, rutin, and isoquercitrin) in H. sabdariffa leaves was developed. The method was validated for linearity, sensitivity, precision, repeatability and accuracy. The validated method has been successfully applied for determination of the five analytes in eight accessions of H. sabdariffa. The eight accessions of H. sabdariffa were evaluated for their antioxidant activities by DPPH free radical scavenging assay. The investigated accessions of H. sabdariffa were rich in rutin and exhibited strong antioxidant activity. The two accessions showing the highest antioxidant activities were from Cuba (No. 2) and Taiwan (No. 5). The results indicated that H. sabdariffa leaves could be considered as a potential antioxidant source for the food industry. The developed LC-Q-TOF-MS method is helpful for quality control of H. sabdariffa.

  18. Determination of Dextromethorphan in Oral Fluid by LC-MS-MS.

    Science.gov (United States)

    Amaratunga, Piyadarsha; Clothier, Morgan; Lorenz Lemberg, Bridget; Lemberg, Dave

    2016-06-01

    Dextromethorphan (DXM) is an antitussive drug found in commonly used nonprescription cold and cough medications. At low doses, DXM is a safe drug that does not produce adverse reactions. However, abuse of DXM has been reported among adolescents and young adults using the drug at higher doses. DXM is not a scheduled drug in the USA, and the primary reason for its abuse is the ease of availability. DXM is available to purchase in the form of over-the-counter cough medications, such as Robitussin(®) and Coricidin(®), or it can be purchased over the Internet in the form of a powder. In this research work, we developed an LC-MS-MS method that can quantify DXM and dextrorphan (DXO) in oral fluid in a high-throughput toxicology laboratory setting. The developed method was validated according to the Scientific Working Group for Forensic Toxicology guidelines. The linear dynamic range was 5-100 ng/mL with a lowest limit of quantitation (LLOQ) of 5.0 ng/mL for DXM and DXO. Overall, the results of the accuracy and the precision values were within the acceptance criteria for both drugs. In addition, selectivity, matrix effect and recovery were calculated for the LC-MS-MS method. Authentic samples (n = 59) were tested to evaluate the applicability of the method. Thirty samples were found to be positive for DXM and DXO and two samples were found to be positive for DXM only. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. OPTIMIZATION AND VALIDATION OF HPLC METHOD FOR TETRAMETHRIN DETERMINATION IN HUMAN SHAMPOO FORMULATION.

    Science.gov (United States)

    Zeric Stosic, Marina Z; Jaksic, Sandra M; Stojanov, Igor M; Apic, Jelena B; Ratajac, Radomir D

    2016-11-01

    High-performance liquid chromatography (HPLC) method with diode array detection (DAD) were optimized and validated for separation and determination of tetramethrin in an antiparasitic human shampoo. In order to optimize separation conditions, two different columns, different column oven temperatures, as well as mobile phase composition and ratio, were tested. Best separation was achieved on the Supelcosil TM LC-18- DB column (4.6 x 250 mm), particle size 5 jim, with mobile phase methanol : water (78 : 22, v/v) at a flow rate of 0.8 mL/min and at temperature of 30⁰C. The detection wavelength of the detector was set at 220 nm. Under the optimum chromatographic conditions, standard calibration curve was measured with good linearity [r2 = 0.9997]. Accuracy of the method defined as a mean recovery of tetramethrin from shampoo matrix was 100.09%. The advantages of this method are that it can easily be used for the routine analysis of drug tetramethrin in pharmaceutical formulas and in all pharmaceutical researches involving tetramethrin.

  20. A Validated Method for the Detection and Quantitation of Synthetic ...

    African Journals Online (AJOL)

    NICOLAAS

    A LC-HRMS (liquid chromatography coupled with high resolution mass spectrometry) method for the ... its ease of availability, from head shops (shops selling predomi- ..... cannabinoids in whole blood in plastic containers with several common ...

  1. Quantification of fumarate and investigation of endogenous and exogenous fumarate stability in rat plasma by LC-MS/MS.

    Science.gov (United States)

    Shi, Yao; Tse, Susanna; Rago, Brian; Yapa, Udeni; Li, Fumin; Fast, Douglas M

    2016-04-01

    Fumaric acid is a commonly used excipient in pharmaceutical products. It is not known if its presence may lead to fluctuation of endogenous fumarate levels. An LC-MS/MS method was developed and validated to quantify fumarate in support of a toxicokinetics study. Stability evaluation showed that endogenous fumarate was stable for 6 h at room temperature, while exogenously added fumaric acid was converted to malate within 1 h due to the presence of fumarase. Citric acid, a fumarase inhibitor, prevented the conversion of added fumaric acid in rat plasma. The method was validated in citric acid stabilized rat plasma using a surrogate matrix approach. A discrepancy in stability was observed between endogenous fumarate and exogenously added fumaric acid.

  2. A rapid and sensitive method for the simultaneous analysis of aliphatic and polar molecules containing free carboxyl groups in plant extracts by LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Bonaventure Gustavo

    2009-11-01

    Full Text Available Abstract Background Aliphatic molecules containing free carboxyl groups are important intermediates in many metabolic and signalling reactions, however, they accumulate to low levels in tissues and are not efficiently ionized by electrospray ionization (ESI compared to more polar substances. Quantification of aliphatic molecules becomes therefore difficult when small amounts of tissue are available for analysis. Traditional methods for analysis of these molecules require purification or enrichment steps, which are onerous when multiple samples need to be analyzed. In contrast to aliphatic molecules, more polar substances containing free carboxyl groups such as some phytohormones are efficiently ionized by ESI and suitable for analysis by LC-MS/MS. Thus, the development of a method with which aliphatic and polar molecules -which their unmodified forms differ dramatically in their efficiencies of ionization by ESI- can be simultaneously detected with similar sensitivities would substantially simplify the analysis of complex biological matrices. Results A simple, rapid, specific and sensitive method for the simultaneous detection and quantification of free aliphatic molecules (e.g., free fatty acids (FFA and small polar molecules (e.g., jasmonic acid (JA, salicylic acid (SA containing free carboxyl groups by direct derivatization of leaf extracts with Picolinyl reagent followed by LC-MS/MS analysis is presented. The presence of the N atom in the esterified pyridine moiety allowed the efficient ionization of 25 compounds tested irrespective of their chemical structure. The method was validated by comparing the results obtained after analysis of Nicotiana attenuata leaf material with previously described analytical methods. Conclusion The method presented was used to detect 16 compounds in leaf extracts of N. attenuata plants. Importantly, the method can be adapted based on the specific analytes of interest with the only consideration that the

  3. Chiral liquid chromatography-mass spectrometry (LC-MS/MS) method development for the detection of salbutamol in urine samples.

    Science.gov (United States)

    Chan, Sue Hay; Lee, Warren; Asmawi, Mohd Zaini; Tan, Soo Choon

    2016-07-01

    A sequential solid-phase extraction (SPE) method was developed and validated using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for the detection and quantification of salbutamol enantiomers in porcine urine. Porcine urine samples were hydrolysed with β-glucuronidase/arylsulfatase from Helix pomatia and then subjected to a double solid-phase extraction (SPE) first using the Abs-Elut Nexus SPE and then followed by the Bond Elut Phenylboronic Acid (PBA) SPE. The salbutamol enantiomers were separated using the Astec CHIROBIOTIC™ T HPLC column (3.0mm×100mm; 5μm) maintained at 15°C with a 15min isocratic run at a flow rate of 0.4mL/min. The mobile phase constituted of 5mM ammonium formate in methanol. Salbutamol and salbutamol-tert-butyl-d9 (internal standard, IS) was monitored and quantified with the multiple reaction monitoring (MRM) mode. The method showed good linearity for the range of 0.1-10ng/mL with limit of quantification at 0.3ng/mL. Analysis of the QC samples showed intra- and inter-assay precisions to be less than 5.04%, and recovery ranging from 83.82 to 102.33%. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Determination of perfluorinated compounds in fish fillet homogenates: method validation and application to fillet homogenates from the Mississippi River.

    Science.gov (United States)

    Malinsky, Michelle Duval; Jacoby, Cliffton B; Reagen, William K

    2011-01-10

    We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100±13% with a precision (%RSD) ≤18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Determination of etoricoxib in human plasma using automated on-line solid-phase extraction coupled with LC-APCI/MS/MS

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Dalmora

    2008-01-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v/ammonium acetate (pH 4.0; 10 mM, run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99. The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

  6. ICPD-a new peak detection algorithm for LC/MS.

    Science.gov (United States)

    Zhang, Jianqiu; Haskins, William

    2010-12-01

    The identification and quantification of proteins using label-free Liquid Chromatography/Mass Spectrometry (LC/MS) play crucial roles in biological and biomedical research. Increasing evidence has shown that biomarkers are often low abundance proteins. However, LC/MS systems are subject to considerable noise and sample variability, whose statistical characteristics are still elusive, making computational identification of low abundance proteins extremely challenging. As a result, the inability of identifying low abundance proteins in a proteomic study is the main bottleneck in protein biomarker discovery. In this paper, we propose a new peak detection method called Information Combining Peak Detection (ICPD ) for high resolution LC/MS. In LC/MS, peptides elute during a certain time period and as a result, peptide isotope patterns are registered in multiple MS scans. The key feature of the new algorithm is that the observed isotope patterns registered in multiple scans are combined together for estimating the likelihood of the peptide existence. An isotope pattern matching score based on the likelihood probability is provided and utilized for peak detection. The performance of the new algorithm is evaluated based on protein standards with 48 known proteins. The evaluation shows better peak detection accuracy for low abundance proteins than other LC/MS peak detection methods.

  7. Development and Validation of a Fast Procedure To Analyze Amoxicillin in River Waters by Direct-Injection LC-MS/MS

    OpenAIRE

    Vera Homem; Arminda Alves; Lúcia Silveira Santos

    2014-01-01

    A laboratory application with a strong component in analytical chemistry was designed for undergraduate students, in order to introduce a current problem in the environmental science field, the water contamination by antibiotics. Therefore, a simple and rapid method based on direct injection and high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and optimized for the determination of amoxicillin in river water. Students learned the main optimization steps...

  8. On-line coupled LC-LC-GC for irradiation detection in complex lipid matrices

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Helle, N.; Boegl, K.W.; Schreiber, G.A.

    1993-01-01

    Since sample preparation with HPLC coupled on-line to the GC has been performed for only a few weeks in our laboratory, the results presented give a first look at what can be done by means of this technique. Even difficult samples as the described fish species, where an unequivocal identification regarding an irradiation treatment seemed to become a hopeless enterprise, could be managed. Because of the greater variety of fatty acids in fish ''new'' radiation-induced hydrocarbons were available. According to the theory of Nawar in addition to 16:2 and 17:2 hydrocarbons we have looked for in irradiated meat, further alkadienes appeared in irradiated fish, which were 14:2, 18:2 and 20:2. Analysis of the alkadiene-fraction, transferred to the GC after a two step LC clean up, resulted in an unequivocal identification of all fish samples as well as the fruits and sponge cake. For fruits and sponge cake the detection limit seems to be clearly below 0.5 kGy. It can further be lowered by increasing the amount of lipid whereas the upper limit for a certain LC column has to be determined. In contrast to these samples only qualitative results were obtained for fish. In the case of sponge cake for the first time irradiation of a component of a heat treated food was detected. Further investigations regarding reproducibility, dose dependence and detection limit have to be done. On-line coupled (LC-)LC-GC was proved to be a highly efficient method for analysis of complex samples. In contrast to off-line Florisil column chromatography only a small part of the initial lipid material is needed because the complete hydrocarbon fraction is transferred on-line to the GC. This offers the possibility to analyze even foods with a low fat content like various seafoods. Classification of the hydrocarbon fraction by a two step LC may facilitate the identification of the radiolytic products also if no mass spectrometric detection system is available. (orig./vhe)

  9. High-throughput method for macrolides and lincosamides antibiotics residues analysis in milk and muscle using a simple liquid-liquid extraction technique and liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-MS/MS).

    Science.gov (United States)

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-11-01

    A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.

  10. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  11. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices.

    Science.gov (United States)

    Armstrong, Jenna L; Dills, Russell L; Yu, Jianbo; Yost, Michael G; Fenske, Richard A

    2014-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15-1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78-113% from XAD-2 active air sampling tubes and 71-108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74-94% after time periods ranging from 2-10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method.

  12. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  13. An automated online turboflow cleanup LC/MS/MS method for the determination of 11 plasticizers in beverages and milk.

    Science.gov (United States)

    Ates, Ebru; Mittendorf, Klaus; Senyuva, Hamide

    2013-01-01

    An automated sample preparation technique involving cleanup and analytical separation in a single operation using an online coupled TurboFlow (RP-LC system) is reported. This method eliminates time-consuming sample preparation steps that can be potential sources for cross-contamination in the analysis of plasticizers. Using TurboFlow chromatography, liquid samples were injected directly into the automated system without previous extraction or cleanup. Special cleanup columns enabled specific binding of target compounds; higher MW compounds, i.e., fats and proteins, and other matrix interferences with different chemical properties were removed to waste, prior to LC/MS/MS. Systematic stepwise method development using this new technology in the food safety area is described. Selection of optimum columns and mobile phases for loading onto the cleanup column followed by transfer onto the analytical column and MS detection are critical method parameters. The method was optimized for the assay of 10 phthalates (dimethyl, diethyl, dipropyl, butyl benzyl, diisobutyl, dicyclohexyl, dihexyl, diethylhexyl, diisononyl, and diisododecyl) and one adipate (diethylhexyl) in beverages and milk.

  14. Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin.

    Science.gov (United States)

    Shibata, Kaito; Naito, Takafumi; Okamura, Jun; Hosokawa, Seiji; Mineta, Hiroyuki; Kawakami, Junichi

    2017-11-30

    Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200μg/mL. The lower limit of quantification of cetuximab in human serum was 4μg/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140μg/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r=0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Development of Chiral LC-MS Methods for small Molecules and Their Applications in the Analysis of Enantiomeric Composition and Pharmacokinetic Studies

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Meera Jay [Iowa State Univ., Ames, IA (United States)

    2004-01-01

    The purpose of this research was to develop sensitive LC-MS methods for enantiomeric separation and detection, and then apply these methods for determination of enantiomeric composition and for the study of pharmacokinetic and pharmacodynamic properties of a chiral nutraceutical. Our first study, evaluated the use of reverse phase and polar organic mode for chiral LC-API/MS method development. Reverse phase methods containing high water were found to decrease ionization efficiency in electrospray, while polar organic methods offered good compatibility and low limits of detection with ESI. The use of lower flow rates dramatically increased the sensitivity by an order of magnitude. Additionally, for rapid chiral screening, the coupled Chirobiotic column afforded great applicability for LC-MS method development. Our second study, continued with chiral LC-MS method development in this case for the normal phase mode. Ethoxynonafluorobutane, a fluorocarbon with low flammability and no flashpoint, was used as a substitute solvent for hexane/heptane mobile phases for LC-APCI/MS. Comparable chromatographic resolutions and selectivities were found using ENFB substituted mobile phase systems, although, peak efficiencies were significantly diminished. Limits of detection were either comparable or better for ENFB-MS over heptane-PDA detection. The miscibility of ENFB with a variety of commonly used organic modifiers provided for flexibility in method development. For APCI, lower flow rates did not increase sensitivity as significantly as was previously found for ESI-MS detection. The chiral analysis of native amino acids was evaluated using both APCI and ESI sources. For free amino acids and small peptides, APCI was found to have better sensitivities over ESI at high flow rates. For larger peptides, however, sensitivity was greatly improved with the use of electrospray. Additionally, sensitivity was enhanced with the use of non-volatile additives, This optimized method was then

  16. Survey on acrylamide in roasted coffee and barley and in potato crisps sold in Italy by a LC-MS/MS method.

    Science.gov (United States)

    Bertuzzi, Terenzio; Rastelli, Silvia; Mulazzi, Annalisa; Pietri, Amedeo

    2017-12-01

    A survey on the occurrence of acrylamide (AA) in roasted coffee, barley, and potato crisps was carried out using an intra-lab validated liquid chromatography (LC)-MS (mass spectrometry)/MS method. Over the years 2015-2016, 66 samples of coffee, 22 of roasted barley, and 22 of potato crisps were collected from retail outlets in Italy. AA was detected in almost all samples. In roasted coffee, the level exceeded 450 µg kg -1 , the limit recommended by the European Commission (EC), in 36.4% of the samples. In roasted barley, mean contamination was slightly lower than in coffee and no sample exceeded the EC limit of 2000 µg kg -1 . The AA contamination in potato crisps was remarkable. A percentage of 36.4 (n = 8) showed a value higher than the EC limit of 1000 µg kg -1 . Considering the average consumption of coffee and potato crisps by Italian people, AA exposure is significant and should be decreased.

  17. Development and Validation of Eco-Friendly Liquid Chromatographic and Spectrophotometric Methods for Simultaneous Determination of Coformulated Drugs: Phenylephrine Hydrochloride and Prednisolone Acetate.

    Science.gov (United States)

    Mostafa, Nadia M; Elsayed, Ghada M; Hassan, Nagiba Y; El Mously, Dina A

    2017-11-01

    Five simple, sensitive, and eco-friendly LC and UV spectrophotometric methods have been developed for the simultaneous determination of phenylephrine hydrochloride (PHE) and prednisolone acetate (PRD) in their combined dosage form. The first method was reversed-phase (RP) LC using methanol-water-heptane-1-sulfonic acid sodium salt (75 + 25 + 0.1, v/v/w) as a mobile phase. Separation was achieved using an XSelect HSS reversed-phase C18 analytical column (250 × 4.6 mm, 5µm). The flow rate was 1.0 mL/min and UV detection was done at 230 nm. Quantification was achieved over the concentration ranges of 5-50 µg/mL for PHE and 2-90 µg/mL for PRD. Four spectrophotometric methods were proposed, namely dual wavelength, first derivative of ratio spectra, ratio difference, and mean-centering of ratio spectra. Linearity was observed in the concentration ranges of 10-120 and 5-35 µg/mL for PHE and PRD, respectively, for the spectrophotometric methods. Green solvents were used in the proposed methods because they play a vital role in the analytical methods' influence on the environment. The suggested methods were validated regarding linearity, accuracy, and precision according to the International Conference on Harmonization guidelines, with satisfactory results. These methods could be used as harmless substitutes for routine analysis of the mentioned drugs, with no interference from excipients.

  18. A new simple and rapid LC-ESI-MS/MS method for quantification of plasma oxysterols as dimethylaminobutyrate esters. Its successful use for the diagnosis of Niemann-Pick type C disease.

    Science.gov (United States)

    Boenzi, Sara; Deodato, Federica; Taurisano, Roberta; Martinelli, Diego; Verrigni, Daniela; Carrozzo, Rosalba; Bertini, Enrico; Pastore, Anna; Dionisi-Vici, Carlo; Johnson, David W

    2014-11-01

    Two oxysterols, cholestan-3β,5α,6β-triol (C-triol) and 7-ketocholesterol (7-KC), have been recently proposed as diagnostic markers of Niemann-Pick type C (NP-C) disease, representing a potential alternative diagnostic tool to the more invasive and time consuming filipin test in cultured fibroblasts. Usually, the oxysterols are detected and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using atmospheric pressure chemical ionization (APCI) or electro-spray-ionization (ESI) sources, after a variety of derivatization procedures to enhance sensitivity. We developed a sensitive LC-MS/MS method to quantify the oxysterols in plasma as dimethylaminobutyrate ester, suitable for ESI analysis. This method, with an easy liquid-phase extraction and a short derivatization procedure, has been validated to demonstrate specificity, linearity, recovery, lowest limit of quantification, accuracy and precision. The assay was linear over a concentration range of 0.5-200ng/mL for C-triol and 1.0-200ng/mL for 7-KC. Intra-day and inter-day coefficients of variation (CV%) were <15% for both metabolites. Receiver operating characteristic analysis estimates that the area under curve was 0.998 for C-triol, and 0.972 for 7-KC, implying a significant discriminatory power for the method in this patient population of both oxysterols. In summary, our method provides a simple, rapid and non-invasive diagnostic tool for the biochemical diagnosis of NP-C disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Systematic Assessment of Seven Solvent and Solid-Phase Extraction Methods for Metabolomics Analysis of Human Plasma by LC-MS

    Science.gov (United States)

    Sitnikov, Dmitri G.; Monnin, Cian S.; Vuckovic, Dajana

    2016-12-01

    The comparison of extraction methods for global metabolomics is usually executed in biofluids only and focuses on metabolite coverage and method repeatability. This limits our detailed understanding of extraction parameters such as recovery and matrix effects and prevents side-by-side comparison of different sample preparation strategies. To address this gap in knowledge, seven solvent-based and solid-phase extraction methods were systematically evaluated using standard analytes spiked into both buffer and human plasma. We compared recovery, coverage, repeatability, matrix effects, selectivity and orthogonality of all methods tested for non-lipid metabolome in combination with reversed-phased and mixed-mode liquid chromatography mass spectrometry analysis (LC-MS). Our results confirmed wide selectivity and excellent precision of solvent precipitations, but revealed their high susceptibility to matrix effects. The use of all seven methods showed high overlap and redundancy which resulted in metabolite coverage increases of 34-80% depending on LC-MS method employed as compared to the best single extraction protocol (methanol/ethanol precipitation) despite 7x increase in MS analysis time and sample consumption. The most orthogonal methods to methanol-based precipitation were ion-exchange solid-phase extraction and liquid-liquid extraction using methyl-tertbutyl ether. Our results help facilitate rational design and selection of sample preparation methods and internal standards for global metabolomics.

  20. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    Science.gov (United States)

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Selection of possible signature peptides for the detection of bovine lactoferrin in infant formulas by LC-MS/MS.

    Directory of Open Access Journals (Sweden)

    Mingmei Yuan

    Full Text Available An LC-MS/MS assay based on a signature peptide was developed and fully validated for the quantitation of bovine lactoferrin in infant formulas. Three unreported signature peptides were derived and identified from the tryptic peptides of bovine lactoferrin. The peptide ETTVFENLPEK was used for quantification based on assay performance. The blank matrix camel milk powder and bovine lactoferrin protein standards were mixed and spiked with stable isotope-labeled internal standard to establish a calibration curve. The established method was extensively validated by determining the linearity (R2 > 0.999, sensitivity (limit of quantitation, 0.16 mg/100 g, recovery (83.1-91.6%, precision (RSD < 5.4% and repeatability (RSD < 7.7%. To validate the applicability of the method, four different brands of infant formulas in China were analysed. The acquired contents of bovine lactoferrin were 52.60-150.56 mg/100 g.

  2. Development and validation of an LC-MS/MS method for the quantification of tiamulin, trimethoprim, tylosin, sulfadiazine and sulfamethazine in medicated feed.

    Science.gov (United States)

    Patyra, Ewelina; Nebot, Carolina; Gavilán, Rosa Elvira; Cepeda, Alberto; Kwiatek, Krzysztof

    2018-01-22

    A new multi-compound method for the analysis of veterinary drugs, namely tiamulin, trimethoprim, tylosin, sulfadiazine and sulfamethazine was developed and validated in medicated feeds. After extraction, the samples were centrifuged, diluted in Milli-Q water, filtered and analysed by high performance liquid chromatography coupled to tandem mass spectrometry. The separation of the analytes was performed on a biphenyl column with a gradient of 0.1% formic acid in acetonitrile and 0.1% formic acid in Milli-Q water. Quantitative validation was done in accordance with the guidelines laid down in European Commission Decision 2002/657/EC. Method performances were evaluated by the following parameters: linearity (R 2  tiamulin, tylosin and sulfamethazine were detected at the concentration levels declared by the manufacturers. The developed method can therefore be successfully used to routinely control the content and homogeneity of these antibacterial substances in medicated feed. Abbreviations AAFCO - Association of American Feed Control Officials; TYL - tylosin; TIAM - tiamulin fumarate; TRIM - trimethoprim; SDZ - sulfadiazine; SMZ - sulfamethazine; UV - ultraviolet detector; FLD - fluorescence detector; HPLC - high performance liquid chromatography; MS/MS - tandem mass spectrometry; LOD - limit of detection; LOQ - limit of quantification; CV - coefficient of variation; SD - standard deviation; U - uncertainty.

  3. Rapid and Sensitive LC-MS/MS Method for the Determination of Metoprolol in Beagle Dog Plasma with a Simple Protein Precipitation Treatment and Its Pharmacokinetic Applications

    Directory of Open Access Journals (Sweden)

    Aihua Hong

    2012-03-01

    Full Text Available : A rapid LC-MS/MS method with good accuracy and sensitivity was developed and validated for the pharmacokinetics study of metoprolol (MP in beagle dogs. The plasma samples were simply precipitated by methanol and then analyzed by LC-MS/MS. An Ultimate XB-C18 column (150 × 2.1 mm ID, 5 μm was used for separation, with methanol-water containing 0.2% formic acid (65:35, v/v as the mobile phase at a flow rate of 0.2 mL/min. Monitoring ions of MP and internal standard (hydroxypioglitazone were m/z 268.1/115.6 and m/z 373.1/150.2, respectively. The linear range was 3.03–416.35 ng/mL with an average correlation coefficient of 0.9996, and the limit of quantification was 3.03 ng/mL. The intra- and inter-day precision was less than 15%. At low, middle and high concentrations, the recovery, the matrix effect and the accuracy was in the range of 76.06%–95.25%, 93.67%–104.19% and 95.20%–99.96% respectively. The method was applied for the pharmacokinetics study of MP tartrate tablets (50 mg. The AUC0-t, Tmax and Cmax were respectively 919.88 ± 195.67 μg/L·h, 0.96 ± 0.33 h, 349.12 ± 78.04 ng/mL.

  4. Development and validation of a rapid, selective, and sensitive LC-MS/MS method for simultaneous determination of D- and L-amino acids in human serum: application to the study of hepatocellular carcinoma.

    Science.gov (United States)

    Han, Minlu; Xie, Mengyu; Han, Jun; Yuan, Daoyi; Yang, Tian; Xie, Ying

    2018-04-01

    A validated liquid chromatography-tandem mass spectrometry method was developed for the simultaneous determination of D- and L-amino acids in human serum. Under the optimum conditions, except for DL-proline, L-glutamine, and D-lysine, the enantioseparation of the other 19 enantiomeric pairs of proteinogenic amino acids and nonchiral glycine was achieved with a CROWNPAK CR-I(+) chiral column within 13 min. The lower limits of quantitation for L-amino acids (including glycine) and D-amino acids were 5-56.25 μM and 0.625-500 nM, respectively, in human serum. The intraday precision and interday precision for all the analytes were less than 15%, and the accuracy ranged from -12.84% to 12.37% at three quality control levels. The proposed method, exhibiting high rapidity, enantioresolution, and sensitivity, was successfully applied to the quantification of D- and L-amino acid levels in serum from hepatocellular carcinoma patients and healthy individuals. The serum concentrations of L-arginine, L-isoleucine, L-aspartate, L-tryptophan, L-alanine, L-methionine, L-serine, glycine, L-valine, L-leucine, L-phenylalanine, L-threonine, D-isoleucine, D-alanine, D-glutamate, D-glutamine, D-methionine, and D-threonine were significantly reduced in the hepatocellular carcinoma patients compared with the healthy individuals (P hepatocellular carcinoma research. Graphical abstract Simultaneous determination of D- and L-amino acids in human serum from hepatocellular carcinoma patients and healthy individuals. AA amino acid, HCC hepatocellular carcinoma, LC liquid chromatography, MS/MS tandem mass spectrometry, NC normal control, TIC total ion chromatogram.

  5. A method for the determination of acrylamide in bakery products using ion trap LC-ESI-MS/MS.

    Science.gov (United States)

    Claus, Achim; Weisz, Georg M; Kammerer, Dietmar R; Carle, Reinhold; Schieber, Andreas

    2005-10-01

    Acrylamide levels of bakery products, e. g., bread and bread rolls, are usually below 100 microg/kg , often even below 50 microg/kg. Therefore, usual analytical methods which have an LOQ greater, not dbl equals 25 microg/kg are not sensitive enough for detailed investigations on acrylamide formation within these commodities. An improved method for trace level determination of acrylamide in bakery products was developed using ion trap LC-ESI-MS/MS. Samples were divided into crumbs and crusts to achieve an initial concentration by removing the crumbs since these are devoid of acrylamide. After sample extraction and clean-up using multimode SPE cartridges, further analyte enrichment was accomplished by solid-phase-supported liquid-liquid extraction with ethyl acetate prior to LC-MS/MS analysis. The method was evaluated using bread, bread rolls, alkali-baked bread rolls, and toast. LOQ was calculated from the confidence interval of the calibration curve and found to be 1.7 ng/mL, corresponding to 17 microg/kg of product. When crumbs and crusts were separated, an LOQ of 10.2 microg/kg of bakery product could be obtained. As demonstrated in preliminary comparative analyses, accuracy of the method met the requirements for determination of trace level acrylamide formation in bakery products. Mean recovery was 102.4% (CV 4.5%), intermediate reproducibility revealed a CV of 2.1%, and a repeatability of CV 6.0%.

  6. LC Quadrature Generation in Integrated Circuits

    DEFF Research Database (Denmark)

    Christensen, Kåre Tais

    2001-01-01

    Today quadrature signals for IQ demodulation are provided through RC polyphase networks, quadrature oscillators or double frequency VCOs. This paper presents a new method for generating quadrature signals in integrated circuits using only inductors and capacitors. This LC quadrature generation...

  7. Results of a proficiency test for multi-mycotoxin determination in maize by using methods based on LC-MS/(MS)

    NARCIS (Netherlands)

    Solfrizzo, M.; Girolamo, De A.; Lattanzio, V.M.T.; Visconti, A.; Stroka, J.; Alldrick, A.; Egmond, van H.P.

    2013-01-01

    Liquid chromatography coupled with single or tandem mass spectrometry (LC-MS/(MS)) is routinely used for the simultaneous determination of mycotoxins in food and feed although official methods using this technique have not yet been adopted by the European Committee for Standardization and the

  8. Development of Chromatographic Fingerprints of Eurycoma longifolia (Tongkat Ali Roots Using Online Solid Phase Extraction-Liquid Chromatography (SPE-LC

    Directory of Open Access Journals (Sweden)

    Nor Nasriah Zaini

    2016-04-01

    Full Text Available E. longifolia is attracting interest due to its pharmacological properties and pro-vitality effects. In this study, an online SPE-LC approach using polystyrene divinyl benzene (PSDVB and C18 columns was developed in obtaining chromatographic fingerprints of E. longifolia. E. longifolia root samples were extracted using pressurized liquid extraction (PLE technique prior to online SPE-LC. The effects of mobile phase compositions and column switching time on the chromatographic fingerprint were optimized. Validation of the developed method was studied based on eurycomanone. Linearity was in the range of 5 to 50 µg∙mL−1 (r2 = 0.997 with 3.2% relative standard deviation of peak area. The developed method was used to analyze 14 E. longifolia root samples and 10 products (capsules. Selected chemometric techniques: cluster analysis (CA, discriminant analysis (DA, and principal component analysis (PCA were applied to the fingerprint datasets of 37 selected peaks to evaluate the ability of the chromatographic fingerprint in classifying quality of E. longifolia. Three groups were obtained using CA. DA yielded 100% correlation coefficient with 19 discriminant compounds. Using PCA, E. longifolia root samples were clearly discriminated from the products. This study showed that the developed online SPE-LC method was able to provide comprehensive evaluation of E. longifolia samples for quality control purposes.

  9. Multiresidue method for pesticide residue analysis in food of animal and plant origin based on GC or LC and MS or MS/MS.

    Science.gov (United States)

    Muñoz, Eva; Muñoz, Gloria; Pineda, Laura; Serrahima, Eulalia; Centrich, Francesc

    2012-01-01

    A multiresidue method based on GC or LC and MS or MS/MS for the determination of 204 pesticides in diverse food matrixes of animal and plant origin is described. The method can include different stages of cleanup according to the chemical characteristics of each sample. Samples were extracted using accelerated solvent extraction. Those with a high fat content or that contained chlorophyll required further purification by gel permeation chromatography and/or SPE (ENVI-Carb). The methodology developed here was fully validated; the LOQs for the 204 pesticides are presented. The LOQ values lie between 0.01 to 0.02 mg/kg. However, in some cases, mainly in baby food, they were as low as 0.003 mg/kg, thereby meeting European Union requirements on maximum residue levels for pesticides, as outlined in European regulation 396/2005 and the Commission Directive 2003/13/EC. The procedure has been accredited for a wide scope of pesticides and matrixes by the Spanish Accreditation Body (ENAC) following ISO/IEC 17025:2005, as outlined in ENAC technical note NT-19.

  10. The development and validation of an UHPLC-MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma.

    Science.gov (United States)

    Seserko, Lauren A; Emory, Joshua F; Hendrix, Craig W; Marzinke, Mark A

    2013-11-01

    Dapivirine is a non-nucleoside reverse transcriptase inhibitor designed to prevent HIV-1 viral replication and subsequent propagation. A sensitive method is required to quantify plasma concentrations to assess drug efficacy. Dapivirine-spiked plasma was combined with acetonitrile containing deuterated IS and was processed for analysis. The method has an analytical measuring range from 20 to 10,000 pg/ml. For the LLOQ, low, mid and high QCs, intra- and inter-assay precision (%CV) ranged from 5.58 to 13.89% and 5.23 to 13.36%, respectively, and intra- and inter-day accuracy (% deviation) ranged from -5.61 to 0.75% and -4.30 to 6.24%, respectively. A robust and sensitive LC-MS/MS assay for the high-throughput quantification of the antiretroviral drug dapivirine in human plasma was developed and validated following bioanalytical validation guidelines. The assay meets criteria for the analysis of samples from large research trials.

  11. A simple LC-MS/MS method for quantitative analysis of underivatized neurotransmitters in rats urine: assay development, validation and application in the CUMS rat model.

    Science.gov (United States)

    Zhai, Xue-jia; Chen, Fen; Zhu, Chao-ran; Lu, Yong-ning

    2015-11-01

    Many amino acid neurotransmitters in urine are associated with chronic stress as well as major depressive disorders. To better understand depression, an analytical LC-MS/MS method for the simultaneous determination of 11 underivatized neurotransmitters (4-aminohippurate, 5-HIAA, glutamate, glutamine, hippurate, pimelate, proline, tryptophan, tyramine, tyrosine and valine) in a single analytical run was developed. The advantage of this method is the simple preparation in that there is no need to deconjugate the urine samples. The quantification range was 25-12,800 ng mL(-1) with >85.8% recovery for all analytes. The nocturnal urine concentrations of the 11 neurotransmitters in chronic unpredictable mild stress (CUMS) model rats and control group (n = 12) were analyzed. A series of significant changes in urinary excretion of neurotransmitters could be detected: the urinary glutamate, glutamine, hippurate and tyramine concentrations were significantly lower in the CUMS group. In addition, the urinary concentrations of tryptophan as well as tyrosine were significantly higher in chronically stressed rats. This method allows the assessment of the neurotransmitters associated with CUMS in rat urine in a single analytical run, making it suitable for implementation as a routine technique in depression research. Copyright © 2015 John Wiley & Sons, Ltd.

  12. MassCascade: Visual Programming for LC-MS Data Processing in Metabolomics.

    Science.gov (United States)

    Beisken, Stephan; Earll, Mark; Portwood, David; Seymour, Mark; Steinbeck, Christoph

    2014-04-01

    Liquid chromatography coupled to mass spectrometry (LC-MS) is commonly applied to investigate the small molecule complement of organisms. Several software tools are typically joined in custom pipelines to semi-automatically process and analyse the resulting data. General workflow environments like the Konstanz Information Miner (KNIME) offer the potential of an all-in-one solution to process LC-MS data by allowing easy integration of different tools and scripts. We describe MassCascade and its workflow plug-in for processing LC-MS data. The Java library integrates frequently used algorithms in a modular fashion, thus enabling it to serve as back-end for graphical front-ends. The functions available in MassCascade have been encapsulated in a plug-in for the workflow environment KNIME, allowing combined use with e.g. statistical workflow nodes from other providers and making the tool intuitive to use without knowledge of programming. The design of the software guarantees a high level of modularity where processing functions can be quickly replaced or concatenated. MassCascade is an open-source library for LC-MS data processing in metabolomics. It embraces the concept of visual programming through its KNIME plug-in, simplifying the process of building complex workflows. The library was validated using open data.

  13. Quantitative analysis of factor P (Properdin) in monkey serum using immunoaffinity capturing in combination with LC-MS/MS.

    Science.gov (United States)

    Gao, Xinliu; Lin, Hui; Krantz, Carsten; Garnier, Arlette; Flarakos, Jimmy; Tse, Francis L S; Li, Wenkui

    2016-01-01

    Factor P (Properdin), an endogenous glycoprotein, plays a key role in innate immune defense. Its quantification is important for understanding the pharmacodynamics (PD) of drug candidate(s). In the present work, an immunoaffinity capturing LC-MS/MS method has been developed and validated for the first time for the quantification of factor P in monkey serum with a dynamic range of 125 to 25,000 ng/ml using the calibration standards and QCs prepared in factor P depleted monkey serum. The intra- and inter-run precision was ≤7.2% (CV) and accuracy within ±16.8% (%Bias) across all QC levels evaluated. Results of other evaluations (e.g., stability) all met the acceptance criteria. The validated method was robust and implemented in support of a preclinical PK/PD study.

  14. Accurate LC peak boundary detection for ¹⁶O/¹⁸O labeled LC-MS data.

    Science.gov (United States)

    Cui, Jian; Petritis, Konstantinos; Tegeler, Tony; Petritis, Brianne; Ma, Xuepo; Jin, Yufang; Gao, Shou-Jiang S J; Zhang, Jianqiu Michelle

    2013-01-01

    In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide elution time ranges. In addition, we remove peptides with erroneous mass assignment through model fitness check, which compares observed intensity patterns to theoretically constructed ones. The proposed algorithm can significantly improve the accuracy and precision of peptide ratio measurements.

  15. Bioanalytical method development and validation for the determination of glycine in human cerebrospinal fluid by ion-pair reversed-phase liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jiang, Jian; James, Christopher A; Wong, Philip

    2016-09-05

    A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Eco-friendly LC-MS/MS method for analysis of multi-class micropollutants in tap, fountain, and well water from northern Portugal.

    Science.gov (United States)

    Barbosa, Marta O; Ribeiro, Ana R; Pereira, Manuel F R; Silva, Adrián M T

    2016-11-01

    Organic micropollutants present in drinking water (DW) may cause adverse effects for public health, and so reliable analytical methods are required to detect these pollutants at trace levels in DW. This work describes the first green analytical methodology for multi-class determination of 21 pollutants in DW: seven pesticides, an industrial compound, 12 pharmaceuticals, and a metabolite (some included in Directive 2013/39/EU or Decision 2015/495/EU). A solid-phase extraction procedure followed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (offline SPE-UHPLC-MS/MS) method was optimized using eco-friendly solvents, achieving detection limits below 0.20 ng L -1 . The validated analytical method was successfully applied to DW samples from different sources (tap, fountain, and well waters) from different locations in the north of Portugal, as well as before and after bench-scale UV and ozonation experiments in spiked tap water samples. Thirteen compounds were detected, many of them not regulated yet, in the following order of frequency: diclofenac > norfluoxetine > atrazine > simazine > warfarin > metoprolol > alachlor > chlorfenvinphos > trimethoprim > clarithromycin ≈ carbamazepine ≈ PFOS > citalopram. Hazard quotients were also estimated for the quantified substances and suggested no adverse effects to humans. Graphical Abstract Occurrence and removal of multi-class micropollutants in drinking water, analyzed by an eco-friendly LC-MS/MS method.

  17. A validated LC-MS/MS determination method for the illegal food additive rhodamine B: Applications of a pharmacokinetic study in rats.

    Science.gov (United States)

    Cheng, Yung-Yi; Tsai, Tung-Hu

    2016-06-05

    Rhodamine B is an illegal and potentially carcinogenic food dye. The aim of this study was to develop a convenient, rapid, and sensitive UHPLC-MS/MS method for pharmacokinetic studies in rats. Rat plasma samples were deproteinized with acetonitrile and separated by UHPLC on a reverse-phase C18e column (100mm×2.1mm, 2μm) using a mobile phase consisting of methanol-5mM ammonium acetate (90:10, v/v). Detection was performed using a triple quadrupole tandem mass spectrometer in the selected reaction monitoring mode at [M](+) ion m/z 443.39→399.28 for rhodamine B and [M+H](+) ion m/z 253.17→238.02 for 5-methoxyflavone as the internal standard. This method was specific and produced linear results over a concentration range of 0.5-100ng/mL, with a lower limit of quantitation of 0.5ng/mL. All validation parameters, including the inter-day, intra-day, matrix effect, recovery, and stability in rat plasma, were acceptable according to the biological method validation guidelines developed by the FDA (2001). This method was successfully applied to a pharmacokinetic study in rats; oral administration of 1mg/kg of rhodamine B yielded a time to maximum concentration (Tmax) of 1.3±0.4h and an elimination half-life of 8.8±1.4h, with a clearance of 229.7±19.4mL/h/kg. These pharmacokinetic results provide a constructive contribution to our understanding of the absorption mechanism of rhodamine B and support additional food safety evaluations. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Simultaneous determination of sibutramine and its active metabolites in human plasma by LC-MS/MS and its application to a pharmacokinetic study.

    Science.gov (United States)

    Bae, Jung-Woo; Choi, Chang-Ik; Jang, Choon-Gon; Lee, Seok-Yong

    2011-11-01

    A simple and sensitive liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) technique was developed and validated for the determination of sibutramine and its N-desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t-butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse-phase Luna C18 column with a mobile phase of acetonitrile-10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI-MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05-20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra- and inter-day validation for sibutramine, M1 and M2 were acceptable. This LC-MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.

  19. Combination of pentafluorophenylhydrazine derivatization and isotope dilution LC-MS/MS techniques for the quantification of apurinic/apyrimidinic sites in cellular DNA.

    Science.gov (United States)

    Li, Jie; Leung, Elvis M K; Choi, Martin M F; Chan, Wan

    2013-05-01

    Apurinic/apyrimidinic (AP) sites are common DNA lesions arising from spontaneous hydrolysis of the N-glycosidic bond and base-excision repair mechanisms of the modified bases. Due to the strong association of AP site formation with physically/chemically induced DNA damage, quantifying AP sites provides important information for risk assessment of exposure to genotoxins and oxidative stress. However, rigorous quantification of AP sites in DNA has been hampered by technical problems relating to the sensitivity and selectivity of existing analytical methods. We have developed a new isotope dilution liquid chromatography-coupled tandem mass spectrometry (LC-MS/MS) method for the rigorous quantification of AP sites in genomic DNA. The method entails enzymatic digestion of AP site-containing DNA by endo- and exonucleases, derivatization with pentafluorophenylhydrazine (PFPH), addition of an isotopically labeled PFPH derivative as internal standard, and quantification by LC-MS/MS. The combination of PFPH derivatization with LC-MS/MS analysis on a triple quadrupole mass spectrometer allows for sensitive and selective quantification of AP sites in DNA at a detection limit of 6.5 fmol, corresponding to 4 AP sites/10(9) nt in 5 μg of DNA, which is at least ten times more sensitive than existing analytical methods. The protocol was validated by AP site-containing oligonucleotides and applied in quantifying methyl methanesulfonate-induced formation of AP sites in cellular DNA.

  20. LC-MS-BASED METABOLOMICS OF XENOBIOTIC-INDUCED TOXICITIES

    Directory of Open Access Journals (Sweden)

    Chi Chen

    2013-01-01

    Full Text Available Xenobiotic exposure, especially high-dose or repeated exposure of xenobiotics, can elicit detrimental effects on biological systems through diverse mechanisms. Changes in metabolic systems, including formation of reactive metabolites and disruption of endogenous metabolism, are not only the common consequences of toxic xenobiotic exposure, but in many cases are the major causes behind development of xenobiotic-induced toxicities (XIT. Therefore, examining the metabolic events associated with XIT generates mechanistic insights into the initiation and progression of XIT, and provides guidance for prevention and treatment. Traditional bioanalytical platforms that target only a few suspected metabolites are capable of validating the expected outcomes of xenobiotic exposure. However, these approaches lack the capacity to define global changes and to identify unexpected events in the metabolic system. Recent developments in high-throughput metabolomics have dramatically expanded the scope and potential of metabolite analysis. Among all analytical techniques adopted for metabolomics, liquid chromatography-mass spectrometry (LC-MS has been most widely used for metabolomic investigations of XIT due to its versatility and sensitivity in metabolite analysis. In this review, technical platform of LC-MS-based metabolomics, including experimental model, sample preparation, instrumentation, and data analysis, are discussed. Applications of LC-MS-based metabolomics in exploratory and hypothesis-driven investigations of XIT are illustrated by case studies of xenobiotic metabolism and endogenous metabolism associated with xenobiotic exposure.

  1. Determination of piroxicam from rat articular tissue and plasma based on LC-MS/MS.

    Science.gov (United States)

    Kim, Han Sol; Cho, Ha Ra; Ho, Myoung Jin; Kang, Myung Joo; Choi, Yong Seok

    2016-12-01

    Osteoarthritis (OA) is the most common type of arthritis. To manage OA, in general, oral administration of non-steroidal anti-inflammatory drugs (NSAIDs) is used. Recently, the analgesic and anti-inflammatory efficacy of piroxicam (PX), a long-acting NSAID, by intra-articular (IA) administration in OA was reported, and the possibility that PX is distributed in articular tissues at a certain concentration was raised. Thus, herein, novel LC-MS/MS methods to detect PX in rat articular tissue and plasma are presented. For articular tissue, solvent extraction with acetonitrile for 12 h was employed and a protein precipitation method was used for the preparation of a plasma sample. The developed methods were validated by following the FDA guidelines, and the validated methods were successfully applied to a PK study of IA PX. The present study presents, to our knowledge, the first method of determining a drug in articular tissue. Additionally, the level of PX in articular tissue after IA PX administration was experimentally confirmed for the first time using the present methods. Therefore, the present methods provide a new direction for in vivo evaluation for IA PX formulations and contribute to the development of alternative IA PX formulations with better effects for the treatment of OA.

  2. Simultaneous quantitative analysis of nine vitamin D compounds in human blood using LC-MS/MS.

    Science.gov (United States)

    Abu Kassim, Nur Sofiah; Gomes, Fabio P; Shaw, Paul Nicholas; Hewavitharana, Amitha K

    2016-01-01

    It has been suggested that each member of the family of vitamin D compounds may have different function(s). Therefore, selective quantification of each compound is important in clinical research. Development and validation attempts of a simultaneous determination method of 12 vitamin D compounds in human blood using precolumn derivatization followed by LC-MS/MS is described. Internal standard calibration with 12 stable isotope labeled analogs was used to correct for matrix effects in MS detector. Nine vitamin D compounds were quantifiable in blood samples with detection limits within femtomole levels. Serum (compared with plasma) was found to be a more suitable sample type, and protein precipitation (compared with saponification) a more effective extraction method for vitamin D assay.

  3. Development and validation of an indirect pulsed electrochemical detection method for monitoring the inhibition of Abl1 tyrosine kinase.

    Science.gov (United States)

    Chen, Hui; Wang, Xu; Chopra, Shruti; Adams, Erwin; Van Schepdael, Ann

    2014-03-01

    A new method for monitoring the enzyme inhibition of Abl1 tyrosine kinase by liquid chromatography-indirect pulsed electrochemical detection (LC-InPED) was developed. In this method, adsorption of a peptide analyte at the noble metal electrode suppresses the oxidation of polyols under alkaline condition to elicit an indirect response resulting in a negative peak of the target peptide. Among the reagents tested, D-gluconic acid sodium salt gave the best overall signal to noise (S/N) values for the indirect detection of p-Abltide, the product of Abl1 enzymatic reaction. 50 μM D-gluconic acid sodium salt dissolved in a mixture of 78% water-22% acetonitrile-0.03% trifluoroacetic acid (TFA) was used as the mobile phase. Chromatographic separation was achieved on an Alltima C18 (I.D. 5 μm; 250 mm × 4.6 mm) column with the mobile phase flow rate of 0.5 ml/min. 0.5M sodium hydroxide was added post-column to maintain alkaline conditions in the PED cell. The limit of quantification (LOQ) was 0.2 μM for p-Abltide, which was about 50-fold lower than direct PED analysis. The residual plot of the linear calibration curve indicated a good fit with a linear model within the investigated concentration range of p-Abltide. Intra- and inter-day precision was not more than 6.5% and accuracy was from -5.75% to +1.54%. The validated LC-InPED method was successfully applied for monitoring of p-Abltide in Abl1 enzyme reaction and the inhibition study of Abl1. The determined IC50 values of model inhibitors, imatinib, nilotinib and dasatinib, were 601.4 nM (R(2)=0.99), 32.3 nM (R(2)=0.99) and 1.3 nM (R(2)=0.98), respectively. These results were consistent with literature data. To the best of our knowledge this is the first time a LC-InPED method has been used to monitor an enzyme reaction. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Multiplexed LC-MS/MS analysis of horse plasma proteins to study doping in sport.

    Science.gov (United States)

    Barton, Chris; Beck, Paul; Kay, Richard; Teale, Phil; Roberts, Jane

    2009-06-01

    The development of protein biomarkers for the indirect detection of doping in horse is a potential solution to doping threats such as gene and protein doping. A method for biomarker candidate discovery in horse plasma is presented using targeted analysis of proteotypic peptides from horse proteins. These peptides were first identified in a novel list of the abundant proteins in horse plasma. To monitor these peptides, an LC-MS/MS method using multiple reaction monitoring was developed to study the quantity of 49 proteins in horse plasma in a single run. The method was optimised and validated, and then applied to a population of race-horses to study protein variance within a population. The method was finally applied to longitudinal time courses of horse plasma collected after administration of an anabolic steroid to demonstrate utility for hypothesis-driven discovery of doping biomarker candidates.

  5. Development and validation of an HPLC method to quantify camptothecin in polymeric nanocapsule suspensions.

    Science.gov (United States)

    Granada, Andréa; Murakami, Fabio S; Sartori, Tatiane; Lemos-Senna, Elenara; Silva, Marcos A S

    2008-01-01

    A simple, rapid, and sensitive reversed-phase column high-performance liquid chromatographic method was developed and validated to quantify camptothecin (CPT) in polymeric nanocapsule suspensions. The chromatographic separation was performed on a Supelcosil LC-18 column (15 cm x 4.6 mm id, 5 microm) using a mobile phase consisting of methanol-10 mM KH2PO4 (60 + 40, v/v; pH 2.8) at a flow rate of 1.0 mL/min and ultraviolet detection at 254 nm. The calibration graph was linear from 0.5 to 3.0 microg/mL with a correlation coefficient of 0.9979, and the limit of quantitation was 0.35 microg/mL. The assay recovery ranged from 97.3 to 105.0%. The intraday and interday relative standard deviation values were entrapment efficiency and drug content in polymeric nanocapsule suspensions during the early stage of formulation development.

  6. Passivity Enhancement of Grid-Tied Converter by Series LC-Filtered Active Damper

    DEFF Research Database (Denmark)

    Bai, Haofeng; Wang, Xiongfei; Loh, Poh Chiang

    2015-01-01

    attention. Also, parasitic capacitance of the grid transmission line brings new challenge for the application of an active damper, which has not been discussed before. In order to fill these gaps, this paper first analyzes the stability of a grid-tied converter with the help of passivity. Based......Series LC-filtered active damper can be used to stabilize the grid-tied voltage source converter in a non-ideal grid. The operation principle of the active damper is to mimic a damping resistance at the resonance frequencies. However, the selection of the damping resistance has not received much...... on the passivity-based-stability analysis, a damping resistance selection method is proposed. Then, an admittance shaping method is developed to ensure the system stability in the presence of parasitic capacitance of the transmission line. Finally, experimental results are provided to show the validity...

  7. Validation of a liquid chromatography-triple quadrupole mass spectrometric method for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma and its application to microdose clinical trial.

    Science.gov (United States)

    Park, Min-Ho; Lee, Yun Young; Cho, Kyung Hee; La, Sookie; Lee, Hee Joo; Yim, Dong-Seok; Ban, Sooho; Park, Moon-Young; Kim, Yong-Chul; Kim, Yoon-Gyoon; Shin, Young G

    2016-03-01

    A liquid chromatography-triple quadrupole mass spectrometric (LC-MS/MS) method was developed and validated for the determination of 5-nitro-5'-hydroxy-indirubin-3'-oxime (AGM-130) in human plasma to support a microdose clinical trial. The method consisted of a liquid-liquid extraction for sample preparation and LC-MS/MS analysis in the positive ion mode using TurboIonSpray(TM) for analysis. d3 -AGM-130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10-2000 pg/mL for AGM-130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between-run accuracy ranged from 98.1 to 101.0%. AGM-130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM-130 was also stable in human plasma at room temperature for 6 h and through three freeze-thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC-MS/MS method for determination of AGM-130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.

  8. LC Circuits for Diagnosing Embedded Piezoelectric Devices

    Science.gov (United States)

    Chattin, Richard L.; Fox, Robert Lee; Moses, Robert W.; Shams, Qamar A.

    2005-01-01

    A recently invented method of nonintrusively detecting faults in piezoelectric devices involves measurement of the resonance frequencies of inductor capacitor (LC) resonant circuits. The method is intended especially to enable diagnosis of piezoelectric sensors, actuators, and sensor/actuators that are embedded in structures and/or are components of multilayer composite material structures.

  9. Identification and characterization by LC-UV-MS/MS of melanotan II skin-tanning products sold illegally on the Internet.

    Science.gov (United States)

    Breindahl, Torben; Evans-Brown, Michael; Hindersson, Peter; McVeigh, Jim; Bellis, Mark; Stensballe, Allan; Kimergård, Andreas

    2015-02-01

    New methods were developed and validated to determine the identity, contents, and purity of samples of melanotan II, a synthetic melanocortin receptor agonist, sold in vials as injectable skin-tanning products that were purchased from three online shops. Methods were based on liquid chromatography with ultra-violet detection (LC-UV) at wavelength 218 nm, and tandem mass spectrometric detection (MS/MS) after collision-induced fragmentation of the double charged [M+2H](2+) precursor ion (m/z 513). Identification of melanotan II was verified by correct chromatographic retention time, and relative abundance ratios of five qualifying fragment ions. LC-UV was used to quantify melanotan II as well as impurities. Method validation was performed with reference to guidelines for assessing active substances in authorized medicinal products to reach acceptable accuracy and precision. Vials from two shops contained unknown impurities ranging from 4.1 to 5.9%; impurities from one shop were below the quantification limit. The total amount of melanotan II in vials ranged between 4.32 and 8.84 mg, although each shop claimed that vials contained 10 mg melanotan II. A broad range of drugs used for enhancement purposes can be obtained from the illicit market. However, users of these drugs may be exposed to a range of potential harms, as shown in this study, given that these products are manufactured, distributed and supplied from an illicit market. Copyright © 2014 John Wiley & Sons, Ltd.

  10. Matrix effects break the LC behavior rule for analytes in LC-MS/MS analysis of biological samples.

    Science.gov (United States)

    Fang, Nianbai; Yu, Shanggong; Ronis, Martin Jj; Badger, Thomas M

    2015-04-01

    High-performance liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are generally accepted as the preferred techniques for detecting and quantitating analytes of interest in biological matrices on the basis of the rule that one chemical compound yields one LC-peak with reliable retention time (Rt.). However, in the current study, we have found that under the same LC-MS conditions, the Rt. and shape of LC-peaks of bile acids in urine samples from animals fed dissimilar diets differed significantly among each other. To verify this matrix effect, 17 authentic bile acid standards were dissolved in pure methanol or in methanol containing extracts of urine from pigs consuming either breast milk or infant formula and analyzed by LC-MS/MS. The matrix components in urine from piglets fed formula significantly reduced the LC-peak Rt. and areas of bile acids. This is the first characterization of this matrix effect on Rt. in the literature. Moreover, the matrix effect resulted in an unexpected LC behavior: one single compound yielded two LC-peaks, which broke the rule of one LC-peak for one compound. The three bile acid standards which exhibited this unconventional LC behavior were chenodeoxycholic acid, deoxycholic acid, and glycocholic acid. One possible explanation for this effect is that some matrix components may have loosely bonded to analytes, which changed the time analytes were retained on a chromatography column and interfered with the ionization of analytes in the MS ion source to alter the peak area. This study indicates that a comprehensive understanding of matrix effects is needed towards improving the use of HPLC and LC-MS/MS techniques for qualitative and quantitative analyses of analytes in pharmacokinetics, proteomics/metabolomics, drug development, and sports drug testing, especially when LC-MS/MS data are analyzed by automation software where identification of an analyte is based on its exact molecular weight and Rt

  11. LC-MS/MS methods for the determination of edaravone and/or taurine in rat plasma and its application to a pharmacokinetic study.

    Science.gov (United States)

    Tang, Dao-quan; Bian, Ting-ting; Zheng, Xiao-xiao; Li, Ying; Wu, Xiao-wen; Li, Yin-jie; Du, Qian; Jiang, Shui-shi

    2014-09-01

    Three liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods were respectively developed and validated for the simultaneous or independent determination of taurine and edaravone in rat plasma using 3-methyl-1-p-tolyl-5-pyrazolone and sulfanilic acid as the internal standards (IS). Chromatographic separations were achieved on an Agilent Zorbax SB-Aq (100 × 2.1 mm, 3.5 µm) column. Gradient 0.03% formic acid-methanol, isocratic 0.1% formic acid-methanol (90:10) and 0.02% formic acid-methanol (40:60) were respectively selected as the mobile phase for the simultaneous determination of two analytes, taurine or edaravone alone. The MS acquisition was performed in multiple reaction monitoring mode with a positive and negative electrospray ionization source. The mass transitions monitored were m/z [M + H](+) 175.1 → 133.0 and [M + H](+) 189.2 → 147.0 for edaravone and its IS, m/z [M - H](-) 124.1 → 80.0 and [M - H](-) 172.0 → 80.0 for taurine and its IS, respectively. The validated methods were successfully applied to study the pharmacokinetic interaction of taurine and edaravone in rats after independent intravenous administration and co-administration with a single dose. Our collective results showed that there were no significant alterations on the main pharmacokinetic parameters (area under concentration-time curve, mean residence time, half-life and clearance) of taurine and edaravone, implying that the proposed combination therapy was pharmacologically feasible. Copyright © 2014 John Wiley & Sons, Ltd.

  12. A semi-automated LC-MS/MS method for the determination of LCI699, a steroid 11β-hydroxylase inhibitor, in human plasma.

    Science.gov (United States)

    Li, Wenkui; Luo, Suyi; Rebello, Sam; Flarakos, Jimmy; Tse, Francis L S

    2014-06-01

    A novel liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of LCI699 was developed and validated with dynamic ranges of 0.0500-50.0 ng/mL and 1.00-1,000 ng/mL using 0.0500 mL and 0.100mL, respectively, of human plasma. LCI699 and the internal standard, [M+6]LCI699, were extracted from fortified human plasma via protein precipitation. After transfer or dilution of the supernatant followed by solvent evaporation and/or reconstitution, the extract was injected onto the LC-MS/MS system. Optimal chromatographic separation was achieved on an ACE C18 (50 mm × 4.6mm, 3 μm) column with 30% aqueous methanol (containing 0.5% acetic acid and 0.05% TFA) as the mobile phase run in isocratic at a flow rate of 1.0 mL/min. The total analysis cycle time is approximately 3.5 min per injection. The addition of an ion-pair reagent, TFA (0.05%, v/v), to the mobile phases significantly improved the chromatographic retention and resolution of the analyte on silica based reversed-phase column. Although addition of TFA to the mobile phase suppresses the ESI signals of the analyte due to its ion-pairing characteristics in the gas phase of MS source, this negative impact was effectively alleviated by adding 0.5% acetic acid to the mobile phase. The current method was validated for sensitivity, selectivity, linearity, reproducibility, stability and recovery. For the low curve range (0.0500-50.0 ng/mL), the accuracy and precision for the LLOQs (0.0500 ng/mL) were -13.0 to 2.0% bias and 3.4-19.2% CV, respectively. For other QC samples (0.100, 6.00, 20.0 and 40.0 ng/mL), the precision ranged from 1.2 to 9.0% and from 3.8 to 8.8% CV, respectively, in the intra-day and inter-day evaluations. The accuracy ranged from -11.3 to 8.0% and -7.2 to 1.6% bias, respectively, in the intra-day and inter-day batches. For the high curve range (1.00-1,000 ng/mL), the accuracy and precision for the LLOQs (1.00 ng/mL) were 1.0-15.0% bias and 7.4-9.2% CV

  13. A reliable and validated LC-MS/MS method for the simultaneous quantification of 4 cannabinoids in 40 consumer products.

    Directory of Open Access Journals (Sweden)

    Qingfang Meng

    Full Text Available In the past 50 years, Cannabis sativa (C. sativa has gone from a substance essentially prohibited worldwide to one that is gaining acceptance both culturally and legally in many countries for medicinal and recreational use. As additional jurisdictions legalize Cannabis products and the variety and complexity of these products surpass the classical dried plant material, appropriate methods for measuring the biologically active constituents is paramount to ensure safety and regulatory compliance. While there are numerous active compounds in C. sativa the primary cannabinoids of regulatory and safety concern are (--Δ⁹-tetrahydrocannabinol (THC, cannabidiol (CBD, and their respective acidic forms THCA-A and CBDA. Using the US Food and Drug Administration (FDA bioanalytical method validation guidelines we developed a sensitive, selective, and accurate method for the simultaneous analysis CBD, CBDA, THC, and THCA-A in oils and THC & CBD in more complex matrices. This HPLC-MS/MS method was simple and reliable using standard sample dilution and homogenization, an isocratic chromatographic separation, and a triple quadrupole mass spectrometer. The lower limit of quantification (LLOQ for analytes was 0.195 ng/mL over a 0.195-50.0 ng/mL range of quantification with a coefficient of correlation of >0.99. Average intra-day and inter-day accuracies were 94.2-112.7% and 97.2-110.9%, respectively. This method was used to quantify CBD, CBDA, THC, and THCA-A in 40 commercial hemp products representing a variety of matrices including oils, plant materials, and creams/cosmetics. All products tested met the federal regulatory restrictions on THC content in Canada (1,000 (an oil-based product. Overall, the method proved amenable to the analysis of various commercial products including oils, creams, and plant material and may be diagnostically indicative of adulteration with non-hemp C. sativa, specialized hemp cultivars, or unique manufacturing methods.

  14. Evaluation of various QuEChERS based methods for the analysis of herbicides and other commonly used pesticides in polished rice by LC-MS/MS.

    Science.gov (United States)

    Pareja, Lucía; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, Amadeo R

    2011-02-15

    Four different extraction and clean-up protocols based on the QuEChERS method were compared for the development of an optimized sample preparation procedure for the multiresidue analysis of 16 commonly applied herbicides in rice crops using LC-QqQ/MS. Additionally the methods were evaluated for the analysis of 26 insecticides and fungicides currently used in rice crops. The methods comprise, in general, the hydratation of the sample with water followed by the extraction with acetonitrile, phase separation with the addition of different salts and finally a clean-up step with various sorbents. Matrix effects were evaluated for the 4 studied methods using LC-QqQ/MS. Additionally LC-TOF/MS was used to compare the co-extractants obtained with the four assayed methodologies. Thirty-six pesticides presented good performance with recoveries in the range 70-120% and relative standard deviations below 20% using 7.5 g of milled polished rice and the buffered acetate QuEChERS method without clean-up at both fortification levels: 10 and 300 μg kg(-1). The other six pesticides presented low recovery rates, nevertheless all these analytes could be analyzed with at least one of the other three studied procedures. Copyright © 2010. Published by Elsevier B.V.

  15. LC-MS/MS strategies for therapeutic antibodies and investigation into the quantitative impact of antidrug-antibodies.

    Science.gov (United States)

    Ewles, Matthew; Mannu, Ranbir; Fox, Chris; Stanta, Johannes; Evans, Graeme; Goodwin, Lee; Duffy, James; Bell, Len; Estdale, Sian; Firth, David

    2016-12-01

    We aimed to establish novel, high-throughput LC-MS/MS strategies for quantification of monoclonal antibodies in human serum and examine the potential impact of antidrug antibodies. We present two strategies using a thermally stable immobilized trypsin. The first strategy uses whole serum digestion and the second introduces Protein G enrichment to improve the selectivity. The impact of anti-trastuzumab antibodies on the methods was tested. Whole serum digestion has been validated for trastuzumab (LLOQ 0.25 µg/ml). Protein G enrichment has been validated for trastuzumab (LLOQ 0.1 µg/ml), bevacizumab (LLOQ 0.1 µg/ml) and adalimumab (LLOQ 0.25 µg/ml). We have shown the potential for anti-drug antibodies to impact on the quantification and we have subsequently established a strategy to overcome this impact where total quantification is desired.

  16. A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.

    Science.gov (United States)

    Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal

    2015-01-01

    Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.

  17. Simultaneous determination of seven alkaloids from Rhizoma Corydalis Decumbentis in rabbit aqueous humor by LC-MS/MS: Application to ocular pharmacokinetic studies.

    Science.gov (United States)

    Mao, Zhengsheng; Wang, Xin; Liu, Yangdan; Huang, Yuting; Liu, Youping; Di, Xin

    2017-07-01

    This study aims to establish a fast and sensitive LC-MS/MS method for simultaneous determination of seven alkaloids from Rhizoma Corydalis Decumbentis in rabbit aqueous humor. Aqueous humor samples were processed by protein precipitation and then separated on a Thermo Syncronis C 18 column (50mm×2.1mm, 5μm) with a mobile phase using acetonitrile-0.05% formic acid (28:72, v/v). Detection of the analytes and the internal standard (coptisine) were performed in positive electrospray ionization with selected reaction monitoring. The method showed good linearity (r>0.9931) for all the seven alkaloids. This fully validated method was applied to the studies of aqueous humor pharmacokinetics of seven alkaloids from Rhizoma Corydalis Decumbentis and the effects of borneol on corneal penetration of these alkaloids into aqueous humor. This is the first work that presents a reliable LC-MS/MS method for simultaneous determination of seven alkaloids in rabbit aqueous humor and its application of ocular pharmacokinetics of seven alkaloids from Rhizoma Corydalis Decumbentis. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Finding of pesticides in fashionable fruit juices by LC-MS/MS and GC-MS/MS.

    Science.gov (United States)

    Tran, Kevin; Eide, David; Nickols, Susan M; Cromer, Michele R; Sabaa-Srur, Armando; Smith, Robert E

    2012-10-15

    Products labelled as containing extracts from two mushrooms (cordyceps plus reishi) and the juices from açaí, goji, mangosteen, noni, pomegranate, and sea buckthorn have been analysed for 174 different pesticides, using the validated QuEChERS method for sample preparation and electrospray LC-MS/MS in the positive ion mode for analysis. Pesticides were found in 10 of the 21 samples analysed. Most pesticides found were below the tolerance levels (1-6 μg/g, depending on the pesticide), but some were not. This included boscalid, dimethomorph, iprovalicarb, pyridaben, pyrimethanil, and imazalil, for which there is no tolerance reported or zero tolerance in any fruit. However, genuine açaí that was harvested in the state of Pará and lyophilised in Rio de Janeiro had no detectable pesticides, when analysed by both LC-MS/MS and GC-MS/MS, which can detect 213 more pesticides and industrial chemicals. Likewise no pesticides were found in one sample each of cordyceps plus reishi, sea buckthorn and noni. Published by Elsevier Ltd.

  19. A non-biological method for screening active components against influenza virus from traditional Chinese medicine by coupling a LC column with oseltamivir molecularly imprinted polymers.

    Directory of Open Access Journals (Sweden)

    Ya-Jun Yang

    Full Text Available To develop a non-biological method for screening active components against influenza virus from traditional Chinese medicine (TCM extraction, a liquid chromatography (LC column prepared with oseltamivir molecularly imprinted polymer (OSMIP was employed with LC-mass spectrometry (LC-MS. From chloroform extracts of compound TCM liquid preparation, we observed an affinitive component m/z 249, which was identified to be matrine following analysis of phytochemical literatures, OSMIP-LC column on-line of control compounds and MS/MS off-line. The results showed that matrine had similar bioactivities with OS against avian influenza virus H9N2 in vitro for both alleviating cytopathic effect and hemagglutination inhibition and that the stereostructures of these two compounds are similar while their two-dimensional structures were different. In addition, our results suggested that the bioactivities of those affinitive compounds were correlated with their chromatographic behaviors, in which less difference of the chromatographic behaviors might have more similar bioactivities. This indicates that matrine is a potential candidate drug to prevent or cure influenza for human or animal. In conclusion, the present study showed that molecularly imprinted polymers can be used as a non-biological method for screening active components against influenza virus from TCM.

  20. Comparison of methods, storage conditions, and time to analysis of serum and urine creatinine measured from microsamples by liquid chromatography mass spectrometery (LC/MS) vs. Jaffe.

    Science.gov (United States)

    Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel

    2014-09-01

    Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; Psamples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.

  1. Pharmacokinetic studies of bergapten in dog plasma by using a LC-MS/MS method studies.

    Science.gov (United States)

    Gao, Y; Liu, Y Z; Zhang, X-M; Zhou, Y; Zhang, X; Dong, C-Y

    2013-07-01

    A sensitive LC-MS/MS method was developed for the determination of bergapten in dog plasma. The chromatographic separation was carried out on a Hypersil ODS column with a mobile phase consisting of methanol-water. The plasma sample was precipitated with methanol and prepare for injecting onto the LC-MS/MS system. The detection was performed on a triple quadrupole tandem mass spectrometer by MRM via electro spray ionization source. The standard curve for bergapten was linear over the concentration range of 0.5-500 ng/mL with a lower limit of quantification of 0.5 ng/mL. The inter-day and intra-day precision (R.S.D.%) for bergapten varied between 3.4 and 11.5. The corresponding inter-day and intra-day accuracy (Bias%) ranged between -3.8 and 6.9. For the pharmacokinetic analysis of serum, the mean (SD) values obtained for the bergapten were as follows: Cmax, 228.5 (14.3) ng/ml; Tmax, 4.2 (0.4) h; t1/2, 6.9 (2.3) h; AUC0-t h, 2507.2 (168.5) ng · h/mL and AUC0-∞, 3 219.2 (211.4) ng · h/mL, respectively. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  3. A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

    Science.gov (United States)

    Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi

    2008-01-01

    Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC

  4. Development and validation of a liquid chromatography-tandem mass spectrometry method for topotecan determination in beagle dog plasma and its application in a bioequivalence study.

    Science.gov (United States)

    Ye, Ling; Shi, Jian; Wan, Shanhe; Yang, Xiaoshan; Wang, Ying; Zhang, Jiajie; Zheng, Dayong; Liu, Zhongqiu

    2013-11-01

    Topotecan (TPT) is an important anti-cancer drug that inhibits topoisomerase I. A sensitive and robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method that potentially determines TPT in beagle dog plasma is needed for a bioequivalence study of TPT formulations. We developed and validated LC-MS/MS to evaluate TPT in beagle dog plasma in terms of specificity, linearity, precision, accuracy, stability, extraction recovery and matrix effect. Plasma samples were treated with an Ostro(TM) sorbent plate (a robust and effective tool) to eliminate phospholipids and proteins before analysis. TPT and camptothecin (internal standard) were separated on an Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 50 mm) with 0.1% formic acid and methanol as the mobile phase at a flow rate of 0.25 mL/min. TPT was analyzed using positive ion electrospray ionization in multiple-reaction monitoring mode. The obtained lower limit of quantitation was 1 ng/mL (signal-to-noise ratio > 10). The standard calibration curve for TPT was linear (correlation coefficient > 0.99) at the concentration range of 1-400 ng/mL. The intra-day and inter-day precision, accuracy, stability, extraction recovery and matrix effect of TPT were within the acceptable limits. The validated method was successfully applied in a bioequivalence study of TPT in healthy beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Validated LC-MS/MS Method for the Determination of Scopoletin in Rat Plasma and Its Application to Pharmacokinetic Studies

    Directory of Open Access Journals (Sweden)

    Yingchun Zeng

    2015-10-01

    Full Text Available A rapid, sensitive and selective liquid chromatography-electrospray ionization-tandem mass spectrometric method was developed and validated for the quantification of scopoletin in rat plasma. After the addition of the internal standard xanthotoxin, plasma samples were pretreated by a simple one-step protein precipitation with acetonitrile-methanol (2:1, v/v. Chromatographic separation was achieved on a Diamonsil ODS chromatography column using gradient elution with the mobile phase consisting of acetonitrile and 0.1% formic acid. The determination was performed by positive ion electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear over the concentration range of 5–1000 ng/mL (r = 0.9996. The intra- and inter-day precision (RSD% was less than 6.1%, and the accuracy (RE% was from −3.0%–2.5%. This method was successfully applied to the pharmacokinetic research of scopoletin in rats after intravenous (5 mg/kg or oral (5, 10 and 20 mg/kg administration. The result showed that oral bioavailability with a dose of 5 mg/kg was 6.62% ± 1.72%, 10 mg/kg, 5.59% ± 1.16%, and 20 mg/kg, 5.65% ± 0.75%.

  6. In-house validation of a liquid chromatography-tandem mass spectrometry method for the determination of selective androgen receptor modulators (SARMS) in bovine urine.

    Science.gov (United States)

    Schmidt, Kathrin S; Mankertz, Joachim

    2018-06-01

    A sensitive and robust LC-MS/MS method allowing the rapid screening and confirmation of selective androgen receptor modulators in bovine urine was developed and successfully validated according to Commission Decision 2002/657/EC, chapter 3.1.3 'alternative validation', by applying a matrix-comprehensive in-house validation concept. The confirmation of the analytes in the validation samples was achieved both on the basis of the MRM ion ratios as laid down in Commission Decision 2002/657/EC and by comparison of their enhanced product ion (EPI) spectra with a reference mass spectral library by making use of the QTRAP technology. Here, in addition to the MRM survey scan, EPI spectra were generated in a data-dependent way according to an information-dependent acquisition criterion. Moreover, stability studies of the analytes in solution and in matrix according to an isochronous approach proved the stability of the analytes in solution and in matrix for at least the duration of the validation study. To identify factors that have a significant influence on the test method in routine analysis, a factorial effect analysis was performed. To this end, factors considered to be relevant for the method in routine analysis (e.g. operator, storage duration of the extracts before measurement, different cartridge lots and different hydrolysis conditions) were systematically varied on two levels. The examination of the extent to which these factors influence the measurement results of the individual analytes showed that none of the validation factors exerts a significant influence on the measurement results.

  7. Lung Cancer Serum Biomarker Discovery Using Label Free LC-MS/MS

    Science.gov (United States)

    Zeng, Xuemei; Hood, Brian L.; Zhao, Ting; Conrads, Thomas P.; Sun, Mai; Gopalakrishnan, Vanathi; Grover, Himanshu; Day, Roger S.; Weissfeld, Joel L.; Wilson, David O.; Siegfried, Jill M.; Bigbee, William L.

    2011-01-01

    Introduction Lung cancer remains the leading cause of cancer-related death with poor survival due to the late stage at which lung cancer is typically diagnosed. Given the clinical burden from lung cancer, and the relatively favorable survival associated with early stage lung cancer, biomarkers for early detection of lung cancer are of important potential clinical benefit. Methods We performed a global lung cancer serum biomarker discovery study using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in a set of pooled non-small cell lung cancer (NSCLC) case sera and matched controls. Immunoaffinity subtraction was used to deplete the top most abundant serum proteins; the remaining serum proteins were subjected to trypsin digestion and analyzed in triplicate by LC-MS/MS. The tandem mass spectrum data were searched against the human proteome database and the resultant spectral counting data were used to estimate the relative abundance of proteins across the case/control serum pools. The spectral counting derived abundances of some candidate biomarker proteins were confirmed with multiple reaction monitoring MS assays. Results A list of 49 differentially abundant candidate proteins was compiled by applying a negative binomial regression model to the spectral counting data (pbiomarkers with statistically significant differential abundance across the lung cancer case/control pools which, when validated, could improve lung cancer early detection. PMID:21304412

  8. The EIPeptiDi tool: enhancing peptide discovery in ICAT-based LC MS/MS experiments

    Directory of Open Access Journals (Sweden)

    Tradigo Giuseppe

    2007-07-01

    Full Text Available Abstract Background Isotope-coded affinity tags (ICAT is a method for quantitative proteomics based on differential isotopic labeling, sample digestion and mass spectrometry (MS. The method allows the identification and relative quantification of proteins present in two samples and consists of the following phases. First, cysteine residues are either labeled using the ICAT Light or ICAT Heavy reagent (having identical chemical properties but different masses. Then, after whole sample digestion, the labeled peptides are captured selectively using the biotin tag contained in both ICAT reagents. Finally, the simplified peptide mixture is analyzed by nanoscale liquid chromatography-tandem mass spectrometry (LC-MS/MS. Nevertheless, the ICAT LC-MS/MS method still suffers from insufficient sample-to-sample reproducibility on peptide identification. In particular, the number and the type of peptides identified in different experiments can vary considerably and, thus, the statistical (comparative analysis of sample sets is very challenging. Low information overlap at the peptide and, consequently, at the protein level, is very detrimental in situations where the number of samples to be analyzed is high. Results We designed a method for improving the data processing and peptide identification in sample sets subjected to ICAT labeling and LC-MS/MS analysis, based on cross validating MS/MS results. Such a method has been implemented in a tool, called EIPeptiDi, which boosts the ICAT data analysis software improving peptide identification throughout the input data set. Heavy/Light (H/L pairs quantified but not identified by the MS/MS routine, are assigned to peptide sequences identified in other samples, by using similarity criteria based on chromatographic retention time and Heavy/Light mass attributes. EIPeptiDi significantly improves the number of identified peptides per sample, proving that the proposed method has a considerable impact on the protein

  9. Measurement of methionine level with the LC-ESI-MS/MS method in schizophrenic patients.

    Science.gov (United States)

    Kulaksizoglu, S; Kulaksizoglu, B; Ellidag, H Y; Eren, E; Yilmaz, N; Baykal, A

    2016-01-01

    The purpose of this study was to evaluate plasma methionine levels by using liquid chromatography electrospray ionization-tandem mass spectroscopy (LC-ESI-MS/MS) in schizophrenic patients. A twelve-point standard graph was drawn, and the recovery rate, the intra-day and inter-day coefficients of variation (CV), the limit of detection (LOD), and the limit of quantification (LOQ) were evaluated. The y and R2 values of the standard graph equation were determined as 0.011x + 0.0179 and 0.9989, respectively, and the graph remained linear until the 200 µmol/l level. The intra-day coefficients of variation of the samples (n = 10) containing 8, 28, and 58 µmol/l methionine were determined as 2.68, 3.10, and 3.79%, respectively; while their inter-day coefficients of variation were determined as 2.98, 3.19, and 3.84%. The LOD and LOQ values were determined as 0.04 and 0.1 µmol/l, respectively, while the mean recovery rates were determined as 101.7 and 99.3%. Plasma methionine values were measured as 21.5 (19.5-24,6) µmol/l for the patient group, 17.8 (16.3-20.1) µmol/l for the control group, and the difference between the two groups was statistically significant (p = 0.03). LC-ESI-MS/MS method represents a fairly sensitive, economic, and rapid analysis that requires very little sample and is suitable for measuring methionine levels in schizophrenic patients.

  10. A reliable and validated LC-MS/MS method for the simultaneous quantification of 4 cannabinoids in 40 consumer products.

    Science.gov (United States)

    Meng, Qingfang; Buchanan, Beth; Zuccolo, Jonathan; Poulin, Mathieu-Marc; Gabriele, Joseph; Baranowski, David Charles

    2018-01-01

    In the past 50 years, Cannabis sativa (C. sativa) has gone from a substance essentially prohibited worldwide to one that is gaining acceptance both culturally and legally in many countries for medicinal and recreational use. As additional jurisdictions legalize Cannabis products and the variety and complexity of these products surpass the classical dried plant material, appropriate methods for measuring the biologically active constituents is paramount to ensure safety and regulatory compliance. While there are numerous active compounds in C. sativa the primary cannabinoids of regulatory and safety concern are (-)-Δ⁹-tetrahydrocannabinol (THC), cannabidiol (CBD), and their respective acidic forms THCA-A and CBDA. Using the US Food and Drug Administration (FDA) bioanalytical method validation guidelines we developed a sensitive, selective, and accurate method for the simultaneous analysis CBD, CBDA, THC, and THCA-A in oils and THC & CBD in more complex matrices. This HPLC-MS/MS method was simple and reliable using standard sample dilution and homogenization, an isocratic chromatographic separation, and a triple quadrupole mass spectrometer. The lower limit of quantification (LLOQ) for analytes was 0.195 ng/mL over a 0.195-50.0 ng/mL range of quantification with a coefficient of correlation of >0.99. Average intra-day and inter-day accuracies were 94.2-112.7% and 97.2-110.9%, respectively. This method was used to quantify CBD, CBDA, THC, and THCA-A in 40 commercial hemp products representing a variety of matrices including oils, plant materials, and creams/cosmetics. All products tested met the federal regulatory restrictions on THC content in Canada (CBD, the majority of analyzed products contained low CBD levels and a CBD: CBDA ratio of CBD and a CBD: CBDA ratio of >1,000 (an oil-based product). Overall, the method proved amenable to the analysis of various commercial products including oils, creams, and plant material and may be diagnostically indicative of

  11. Direct coupling of a flow-flow electromembrane extraction probe to LC-MS

    DEFF Research Database (Denmark)

    Fuchs, David; Gabel-Jensen, Charlotte; Jensen, Henrik

    2016-01-01

    the fully automated EME-LC-MS system offers a significant time saving and in addition demonstrates increased sensitivity as the analytes were automatically enriched during the extraction process. The experiment revealed 6 to 16 times higher S/N ratios of the EME-LC-MS method compared to protein...... precipitation followed by LC-MS and thus concomitantly lower LOD and LOQ. The setup integrates a complete analytical workflow of rapid extraction, enrichment, separation and detection of analytes in a fully automated manner. These attributes make the developed system a powerful alternative approach for a wide...

  12. Validation of lactate clearance at 6 h for mortality prediction in critically ill children

    OpenAIRE

    Rajeev Kumar; Nirmal Kumar

    2016-01-01

    Background and Aims: To validate the lactate clearance (LC) at 6 h for mortality prediction in Pediatric Intensive Care Unit (PICU)-admitted patients and its comparison with a pediatric index of mortality 2 (PIM 2) score. Design: A prospective, observational study in a tertiary care center. Materials and Methods: Children

  13. The Fate of Sulfamethazine in Sodium-Hypochlorite-Treated Drinking Water: Monitoring by LC-MS-IT-TOF

    Directory of Open Access Journals (Sweden)

    Tyler C. Melton

    2012-01-01

    Full Text Available Pharmaceutical compounds represent a rapidly emerging class of environmental contaminants. Such compounds were recently classified by the U.S. Geological Survey, including several antibiotics. An LC-MS/MS screening method for the top five antibiotics in drinking water was developed and validated using a Shimadzu LC-MS-IT-TOF. The separation was performed using a Waters Acquity UPLC BEH C18 column with a gradient elution. Sulfamethazine was exposed to conditions intended to mimic drinking water chlorination, and samples were collected and quenched with excess sodium sulfite. Kinetics of sulfamethazine degradation was followed as well as the formation of the major chlorinated byproduct (/ 313. For the screening method, all five antibiotic peaks were baseline resolved within 5 minutes. Additionally, precision and accuracy of the screening method were less than 15%. Degradation of sulfamethazine upon exposure to drinking water chlorination occurred by first order kinetics with a half-life of 5.3×104 min (approximately 37 days with measurements starting 5 minutes after chlorination. Likewise, the formation of the major chlorinated product occurred by first order kinetics with a rate constant of 2.0×10−2. The proposed identification of the chlorinated product was 4-amino-(5-chloro-4,6-dimethyl-2-pyrimidinyl-benzenesulfonamide (C12H13N4O2SCl using MS spectra and databases searches of SciFinder and ChemSpider.

  14. Integration of two-dimensional LC-MS with multivariate statistics for comparative analysis of proteomic samples

    NARCIS (Netherlands)

    Gaspari, M.; Verhoeckx, K.C.M.; Verheij, E.R.; Greef, J. van der

    2006-01-01

    LC-MS-based proteomics requires methods with high peak capacity and a high degree of automation, integrated with data-handling tools able to cope with the massive data produced and able to quantitatively compare them. This paper describes an off-line two-dimensional (2D) LC-MS method and its

  15. Validation and application of a liquid chromatography-electrospray ionization mass spectrometric method for determination of mazindol in human plasma and urine.

    Science.gov (United States)

    de Oliveira, Marcella Herbstrith; Ferreira, Pâmela Cristina Lukasewicz; Carlos, Graciela; Salazar, Fernanda Rodrigues; Bergold, Ana Maria; Pechansky, Flavio; Limberger, Renata Pereira; Fröehlich, Pedro Eduardo

    2016-01-01

    Even after removal of some stimulants, like fenproporex, amfepramone and mazindol, from Brazilian market, the use of these substances is still high, especially by drivers. Mazindol is the second most used anorectic agent in the world acting as an indirect sympathomimetic agonist, having stimulatory action on central nervous system. Plasma is a good matrix to monitor since it reflects the psychomotor effects of these drugs, but unlike urine has an invasive collection; drug levels and detection time are quite low. The method involved a liquid-liquid extraction of the samples and a LC-MS analysis was fully validated. Method was used to analyze samples of urine and plasma collected from health volunteers in a period of 24h. Metabolite of mazindol was synthesized using alkaline conditions. After validation the method proved to be adequate to analyze samples collected from health volunteers. Method was linear in the concentration range of 0.1-10ng/mL (r=0.9982) for plasma and 5-50ng/mL (r=0.9973) for urine. Analysis of the samples showed that mazindol can be detected after 1h of administration and that concentration levels in urine were always higher than in plasma. Mazindol metabolite was detected only in urine. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Rapid, Sensitive and Validated Ultra-Performance Liquid Chromatography/Mass Spectrometric Method for the Determination of Fenofibric Acid and its Application to Human Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Sunil K. Dubey

    2010-01-01

    Full Text Available The first, rapid and sensitive ultra performance liquid chromatography mass spectrometric method for the determination of fenofibric acid, the active metabolite of fenofibrate, a lipid regulating agent, in human EDTA plasma has been developed and validated using fenofibric d6 acid as internal standard and Waters LC-MS/MS. Negative ions of fenofibric acid and fenofibric d6 acid were detected in multiple reaction-monitoring (MRM mode. The method was validated over a concentration range of 0.176 μg/mL to 19.837 μg/mL (r ≥ 0.99. It took only 1.5 minute to analyse a sample. Intra- and inter-run precision of fenofibric acid assay at four concentrations ranged from 0.5% to 4.3% with accuracy varied from 93.1 to 108.1% indicating good precision and accuracy. Analytical recoveries of fenofibric acid and internal standard in plasma were less than 90%. This method was successfully applied for evaluation of pharmacokinetics of fenofibric acid after a single oral dose of 145 mg fenofibrate to 10 Indian healthy volunteers

  17. Characterisation of the ester-substituted products of the reaction of p-t-butyl calix[4]arene and ethyl bromoacetate using LC-UV-MS and LC-DAD.

    Science.gov (United States)

    McMahon, Gillian; Wall, Rachel; Nolan, Kieran; Diamond, Dermot

    2002-07-19

    A series of derivatisation reactions between p-t-butyl calix[4]arene and ethyl bromoacetate were carried out in order to prepare 1,3 diester substituted calix[4]arene. Mass spectral data, obtained from direct injection of samples, indicated that the reactions were rich in the desired product. Since the ultra violet (UV) spectra of the desired product and possible impurities are very similar, liquid chromatography (LC) chromatographic data seemed to corroborate these results. However, when on-line LC-UV-MS was carried out and each LC peak subjected to MS analysis as it eluted, a very different picture emerged. It was found that many of these reactions actually contained high levels of the monoester product which, having less affinity for sodium in the MS, is therefore seriously underestimated in any direct injection assay. LC-diode array detection (DAD) methods were also used to help successfully identify and characterise the compounds being formed in these complex reactions. The overall results obtained in this paper allowed the optimal reaction conditions to be determined for this reaction. LC-MS analysis of the chromatographic peaks also identified the presence of two isomers of the diester substituted calix[4]arene (1,3 and 1,2 diesters). The combination of LC and UV/MS detection is required for accurate analysis of the products of such reactions.

  18. Development and validation of a method for detection and quantification of ochratoxin A in green coffee using liquid chromatography coupled to mass spectrometry

    Directory of Open Access Journals (Sweden)

    Raquel Duarte da Costa Cunha Bandeira

    2012-12-01

    Full Text Available A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM for OTA in coffee.

  19. A single LC-tandem mass spectrometry method for the simultaneous determination of 14 antimalarial drugs and their metabolites in human plasma.

    Science.gov (United States)

    Hodel, E M; Zanolari, B; Mercier, T; Biollaz, J; Keiser, J; Olliaro, P; Genton, B; Decosterd, L A

    2009-04-01

    Among the various determinants of treatment response, the achievement of sufficient blood levels is essential for curing malaria. For helping us at improving our current understanding of antimalarial drugs pharmacokinetics, efficacy and toxicity, we have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 200mul of plasma for the simultaneous determination of 14 antimalarial drugs and their metabolites which are the components of the current first-line combination treatments for malaria (artemether, artesunate, dihydroartemisinin, amodiaquine, N-desethyl-amodiaquine, lumefantrine, desbutyl-lumefantrine, piperaquine, pyronaridine, mefloquine, chloroquine, quinine, pyrimethamine and sulfadoxine). Plasma is purified by a combination of protein precipitation, evaporation and reconstitution in methanol/ammonium formate 20mM (pH 4.0) 1:1. Reverse-phase chromatographic separation of antimalarial drugs is obtained using a gradient elution of 20mM ammonium formate and acetonitrile both containing 0.5% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 21min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effect variability, overall process efficiency, standard addition experiments as well as antimalarials short- and long-term stability in plasma. The reactivity of endoperoxide-containing antimalarials in the presence of hemolysis was tested both in vitro and on malaria patients samples. With this method, signal intensity of artemisinin decreased by about 20% in the presence of 0.2% hemolysed red-blood cells in plasma, whereas its derivatives were essentially not affected. The method is precise (inter-day CV%: 3.1-12.6%) and sensitive

  20. LC-QTOF-MS identification of porcine-specific peptide in heat treated pork identifies candidate markers for meat species determination.

    Science.gov (United States)

    Sarah, S A; Faradalila, W N; Salwani, M S; Amin, I; Karsani, S A; Sazili, A Q

    2016-05-15

    The purpose of this study was to identify porcine-specific peptide markers from thermally processed meat that could differentiate pork from beef, chevon and chicken meat. In the initial stage, markers from tryptic digested protein of chilled, boiled and autoclaved pork were identified using LC-QTOF-MS. An MRM method was then established for verification. A thorough investigation of LC-QTOF-MS data showed that only seven porcine-specific peptides were consistently detected. Among these peptides, two were derived from lactate dehydrogenase, one from creatine kinase, and four from serum albumin protein. However, MRM could only detect four peptides (EVTEFAK, LVVITAGAR, FVIER and TVLGNFAAFVQK) that were consistently present in pork samples. In conclusion, meat species determination through a tandem mass spectrometry platform shows high potential in providing scientifically valid and reliable results even at peptide level. Besides, the specificity and selectivity offered by the proteomics approach also provide a robust platform for Halal authentication. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Validation for chromatographic and electrophoretic methods

    OpenAIRE

    Ribani, Marcelo; Bottoli, Carla Beatriz Grespan; Collins, Carol H.; Jardim, Isabel Cristina Sales Fontes; Melo, Lúcio Flávio Costa

    2004-01-01

    The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the dif...

  2. Two complementary liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods to study the excretion and metabolic interaction of edaravone and taurine in rats.

    Science.gov (United States)

    Tang, Dao-quan; Zheng, Xiao-xiao; Li, Yin-jie; Bian, Ting-ting; Yu, Yan-yan; Du, Qian; Yang, Dong-zhi; Jiang, Shui-shi

    2014-11-01

    In this study, two independent and complementary liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods were respectively developed and validated for the determination of edaravone or taurine in rat urine, feces and bile after intravenous administration, using 3-methyl-l-p-tolyl-5-pyrazolone and sulfanilic acid as the internal standards (IS). Edaravone was separated on an Agilent Eclipse Plus C18 column (100×2.1 mm, 3.5 μm) using methanol and water (containing 5 mM ammonium formate and 0.02% formic acid) as mobile phase, while taurine was performed on a Waters Atlantis HILIC Silica column (150×2.1 mm, 3 μm) using acetonitrile and water (containing 5mM ammonium formate and 0.2% formic acid) as mobile phase. The mass analysis was performed in a Triple Quadrupole mass spectrometer via multiple reaction monitoring (MRM) with negative ionization mode. The optimized mass transition ion pairs (m/z) for quantification were 173.1→92.2 and 187.2→106.0 for edaravone and its IS, 124.1→80.0 and 172.0→80.0 for taurine and its IS, respectively. The validated methods have been successfully applied to the excretion and metabolism interaction study of edaravone and taurine in rats after independent intravenous administration and co-administration with a single dose. The results demonstrated that there were no significant alternations on the metabolism and cumulative excretion rate of edaravone and taurine, implying that the proposed combination therapy was pharmacologically viable. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. An improved brine shrimp larvae lethality microwell test method.

    Science.gov (United States)

    Zhang, Yi; Mu, Jun; Han, Jinyuan; Gu, Xiaojie

    2012-01-01

    This article described an improved brine shrimp larvae lethality microwell test method. A simply designed connecting vessel with alternative photoperiod was used to culture and collect high yield of active Artemia parthenogenetica nauplii for brine shrimp larvae lethality microwell test. Using this method, pure A. parthenogenetica nauplii suspension was easily cultured and harvested with high density about 100-150 larvae per milliliter and the natural mortality was reduced to near zero by elimination of unnecessary artificial disturbance. And its sensitivity was validated by determination of LC(50)-24 h of different reference toxicants including five antitumor agents, two pesticides, three organic pollutants, and four heavy metals salts, most of which exhibited LC(50)-24 h between 0.07 and 58.43 mg/L except for bleomycin and mitomycin C with LC(50)-24 h over 300 mg/L.

  4. Determination of antimycin-A in water by liquid chromatographic/mass spectrometry: single-laboratory validation.

    Science.gov (United States)

    Bernardy, Jeffry A; Hubert, Terrance D; Ogorek, Jacob M; Schmidt, Larry J

    2013-01-01

    An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples > or = 500 ng/L and 4.8 to 17% RSD with samples < or = 100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.

  5. Analytical difficulties facing today's regulatory laboratories: issues in method validation.

    Science.gov (United States)

    MacNeil, James D

    2012-08-01

    The challenges facing analytical laboratories today are not unlike those faced in the past, although both the degree of complexity and the rate of change have increased. Challenges such as development and maintenance of expertise, maintenance and up-dating of equipment, and the introduction of new test methods have always been familiar themes for analytical laboratories, but international guidelines for laboratories involved in the import and export testing of food require management of such changes in a context which includes quality assurance, accreditation, and method validation considerations. Decisions as to when a change in a method requires re-validation of the method or on the design of a validation scheme for a complex multi-residue method require a well-considered strategy, based on a current knowledge of international guidance documents and regulatory requirements, as well the laboratory's quality system requirements. Validation demonstrates that a method is 'fit for purpose', so the requirement for validation should be assessed in terms of the intended use of a method and, in the case of change or modification of a method, whether that change or modification may affect a previously validated performance characteristic. In general, method validation involves method scope, calibration-related parameters, method precision, and recovery. Any method change which may affect method scope or any performance parameters will require re-validation. Some typical situations involving change in methods are discussed and a decision process proposed for selection of appropriate validation measures. © 2012 John Wiley & Sons, Ltd.

  6. Effective application of freezing lipid precipitation and SCX-SPE for determination of pyrrolizidine alkaloids in high lipid foodstuffs by LC-ESI-MS/MS.

    Science.gov (United States)

    Yoon, Soo Hwan; Kim, Min-Sun; Kim, Sang Hoon; Park, Hyun Mee; Pyo, Heesoo; Lee, Yong Moon; Lee, Kyung-Tae; Hong, Jongki

    2015-06-15

    Pyrrolizidine alkaloids (PAs) are naturally occurring plant toxins associated with serious hepatic disease in humans and animals. In this study, rapid and sensitive analytical method was developed for the determination of 9 toxic PAs in popularly high lipid foodstuffs by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). PAs in lipid foodstuff were effectively purified by freezing lipid precipitation (FLP) and strong cation exchange (SCX)-solid-phase extraction (SPE). Especially, FLP could easily remove the large amounts of triacylglycerols in the lipid sample extract and effectively combine with SPE cleanup. During the FLP procedure, over 77% of the lipids in the foodstuff extracts were rapidly eliminated without any significant loss of the PAs with over 81% recovery. The elimination efficiency of lipids by FLP was tested with LC-atmospheric chemical ionization (APCI)-MS. For further purification, SCX-SPE cartridge could successfully purify PAs from the remaining interfering substances by the variation pH with 5% NH4OH in methanol. For precise quantification and confirmation of PAs in complicate sample matrices, appropriate transition ions in LC-MS/MS-multiple-ion reaction monitoring (MRM) mode were selected on the basis of MS/MS fragmentation pathways of PAs. The established analytical method was validated in terms of the linearity, limits of detection (LOD), and quantification (LOQ), precision, and accuracy. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision (relative standard deviation<11.06%). Overall limits of detection and quantitation of PAs were approximately 0.06-0.60ng/mL at a signal-to-noise ratio (S/N) of 3 and were about 0.20-1.99ng/mL at a S/N of 10 for all foodstuffs. The established method was successfully applied for the monitoring of toxic PAs in several types of high lipid foodstuffs such as soybeans, seed oil, milk, and margarine. Copyright

  7. Development and validation of LC-MS/MS method with multiple reactions monitoring mode for quantification of vanillin and syringaldehyde in plum brandies

    Directory of Open Access Journals (Sweden)

    Tešević Vele

    2014-01-01

    Full Text Available An ultra-performance liquid chromatography-triple quadrupole mass spectrometry (UPLC-QqQ-MS/MS method with multiple reactions monitoring mode (MRM has been developed and validated for quantification of vanillin and syringaldehyde in plum brandy. The method showed good linearity (0.05 to 10 mgL−1 and low limits of detection and quantification (LOD and LOQ were 11.6 µgL−1 and 38.2 µgL−1 for vanillin, and 12.7 µgL−1 and 42.0 µgL−1 for syringaldehyde, respectively. The overall intra-day and inter-day variations were less than 4.21%, and the overall recovery over 93.0%. The correlation coefficients (R2 of the calibration curves were higher than 0.9999. In order to evaluate if the method is suitable for use as a routine analytical tool, in 31 Serbian plum brandy samples vanillin and syringaldehide were determined. [Projekat Ministarstva nauke Republike Srbije, br. 172053

  8. LC-MS/MS method development for quantitative analysis of acetaminophen uptake by the aquatic fungus Mucor hiemalis.

    Science.gov (United States)

    Esterhuizen-Londt, Maranda; Schwartz, Katrin; Balsano, Evelyn; Kühn, Sandra; Pflugmacher, Stephan

    2016-06-01

    Acetaminophen is a pharmaceutical, frequently found in surface water as a contaminant. Bioremediation, in particular, mycoremediation of acetaminophen is a method to remove this compound from waters. Owing to the lack of quantitative analytical method for acetaminophen in aquatic organisms, the present study aimed to develop a method for the determination of acetaminophen using LC-MS/MS in the aquatic fungus Mucor hiemalis. The method was then applied to evaluate the uptake of acetaminophen by M. hiemalis, cultured in pellet morphology. The method was robust, sensitive and reproducible with a lower limit of quantification of 5 pg acetaminophen on column. It was found that M. hiemalis internalize the pharmaceutical, and bioaccumulate it with time. Therefore, M. hiemalis was deemed a suitable candidate for further studies to elucidate its pharmaceutical tolerance and the longevity in mycoremediation applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. A Collaborative Evaluation of LC-MS/MS Based Methods for BMAA Analysis: Soluble Bound BMAA Found to Be an Important Fraction

    Directory of Open Access Journals (Sweden)

    Elisabeth J. Faassen

    2016-02-01

    Full Text Available Exposure to β-N-methylamino-l-alanine (BMAA might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer’s disease and Parkinson’s disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS analysis, or directly followed by LC-MS/MS analysis for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D3BMAA, the underivatized methods were accurate (mean recovery 80% and precise (mean relative standard deviation 10%, except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds showed higher variation (relative standard deviation 21%–32%, implying that D3BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%. Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis.

  10. A LC-MS-MS method for determination of low doxazosin concentrations in plasma after oral administration to dogs.

    Science.gov (United States)

    Erceg, Marijana; Cindric, Mario; Pozaic Frketic, Lidija; Vertzoni, Maria; Cetina-Cizmek, Biserka; Reppas, Christos

    2010-02-01

    A rapid and sensitive reversed phase liquid chromatography- tandem mass spectrometry (LC-MS-MS) method is developed for the determination of doxazosin in canine plasma. The samples are prepared by precipitation of proteins using a mixture of methanol and acetonitrile, followed by freezing and evaporation of the organic solvent. The remaining dry residue is redissolved in mobile phase and analyzed by LC-MS-MS with positive electrospray ionization using the selected reactions monitoring mode. An XTerra MS C(18) column, a mobile phase composed of acetonitrile and 2mM ammonium acetate with gradient elution, and a flow rate of 400 microL/min are employed. The elution times for prazosin (internal standard) and doxazosin are approximately 8 and 10 min, respectively. Calibration curves are linear in the 1-20 ng/mL concentration range. Limits of detection and quantification are 0.4 ng/mL and 1.2 ng/mL, respectively. Recovery is higher than 94%. Intra- and inter-day relative standard deviations are below 7% and 8%, respectively. The method is applied for the determination of doxazosin plasma levels following a single administration of doxazosin base and doxazosin mesylate tablets (2 mg dose) to dogs in the fed state. The results indicate possible superiority of the mesylate salt on the plasma input rates of doxazosin.

  11. Reduction of Solvent Effect in Reverse Phase Gradient Elution LC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Patrick Allen [Iowa State Univ., Ames, IA (United States)

    2005-12-17

    Quantification in liquid chromatography (LC) is becoming very important as more researchers are using LC, not as an analytical tool itself, but as a sample introduction system for other analytical instruments. The ability of LC instrumentation to quickly separate a wide variety of compounds makes it ideal for analysis of complex mixtures. For elemental speciation, LC is joined with inductively coupled plasma mass spectrometry (ICP-MS) to separate and detect metal-containing, organic compounds in complex mixtures, such as biological samples. Often, the solvent gradients required to perform complex separations will cause matrix effects within the plasma. This limits the sensitivity of the ICP-MS and the quantification methods available for use in such analyses. Traditionally, isotope dilution has been the method of choice for LC-ICP-MS quantification. The use of naturally abundant isotopes of a single element in quantification corrects for most of the effects that LC solvent gradients produce within the plasma. However, not all elements of interest in speciation studies have multiple naturally occurring isotopes; and polyatomic interferences for a given isotope can develop within the plasma, depending on the solvent matrix. This is the case for reverse phase LC separations, where increasing amounts of organic solvent are required. For such separations, an alternative to isotope dilution for quantification would be is needed. To this end, a new method was developed using the Apex-Q desolvation system (ESI, Omaha, NE) to couple LC instrumentation with an ICP-MS device. The desolvation power of the system allowed greater concentrations of methanol to be introduced to the plasma prior to destabilization than with direct methanol injection into the plasma. Studies were performed, using simulated and actual linear methanol gradients, to find analyte-internal standard (AIS) pairs whose ratio remains consistent (deviations {+-} 10%) over methanol concentration ranges of 5

  12. Validated LC-MS/MS Method for the Quantification of Ponatinib in Plasma: Application to Metabolic Stability.

    Directory of Open Access Journals (Sweden)

    Adnan A Kadi

    Full Text Available In the current work, a rapid, specific, sensitive and validated liquid chromatography tandem mass-spectrometric method was developed for the quantification of ponatinib (PNT in human plasma and rat liver microsomes (RLMs with its application to metabolic stability. Chromatographic separation of PNT and vandetanib (IS were accomplished on Agilent eclipse plus C18 analytical column (50 mm × 2.1 mm, 1.8 μm particle size maintained at 21±2°C. Flow rate was 0.25 mLmin-1 with run time of 4 min. Mobile phase consisted of solvent A (10 mM ammonium formate, pH adjusted to 4.1 with formic acid and solvent B (acetonitrile. Ions were generated by electrospray (ESI and multiple reaction monitoring (MRM was used as basis for quantification. The results revealed a linear calibration curve in the range of 5-400 ngmL-1 (r2 ≥ 0.9998 with lower limit of quantification (LOQ and lower limit of detection (LOD of 4.66 and 1.53 ngmL-1 in plasma, 4.19 and 1.38 ngmL-1 in RLMs. The intra- and inter-day precision and accuracy in plasma ranged from1.06 to 2.54% and -1.48 to -0.17, respectively. Whereas in RLMs ranged from 0.97 to 2.31% and -1.65 to -0.3%. The developed procedure was applied for quantification of PNT in human plasma and RLMs for study metabolic stability of PNT. PNT disappeared rapidly in the 1st 10 minutes of RLM incubation and the disappearance plateaued out for the rest of the incubation. In vitro half-life (t1/2 was 6.26 min and intrinsic clearance (CLin was 15.182± 0.477.

  13. Stability-indicating RP-HPLC method for the simultaneous determination of escitalopram oxalate and clonazepam.

    Science.gov (United States)

    Kakde, Rajendra B; Satone, Dinesh D; Gadapayale, Kamalesh K; Kakde, Megha G

    2013-07-01

    The objective of the current study was to develop a validated, specific stability-indicating reversed-phase liquid chromatographic (LC) method for the quantitative determination of escitalopram oxalate and clonazepam and their related substances in bulk drugs and pharmaceutical dosage forms in the presence of degradation products. Forced degradation studies were performed on the pure drugs of escitalopram oxalate and clonazepam, as per the stress conditions prescribed by the International Conference on Harmonization (ICH) using acid, base, oxidation, thermal stress and photolytic degradation to show the stability-indicating power of the method. Significant degradation was observed during acid and alkaline hydrolysis and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies. Good resolution between the peaks corresponded to the active pharmaceutical ingredients, escitalopram oxalate and clonazepam, and degradation products from the analyte were achieved on an ODS Hypersil C18 column (250 × 4.6 mm) using a mobile phase consisting of a mixture of acetonitrile-50 mM phosphate buffer + 10 mM triethylamine (70:30, v/v). The detection was conducted at 268 nm. The limit of detection and the limit of quantitation for escitalopram oxalate and clonazepam were established. The stress test solutions were assayed against the qualified working standards of escitalopram oxalate and clonazepam, which indicated that the developed LC method was stability-indicating. Validation of the developed LC method was conducted as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of escitalopram oxalate and clonazepam.

  14. Development and validation of a rapid multi-biomarker liquid chromatography/tandem mass spectrometry method to assess human exposure to mycotoxins.

    Science.gov (United States)

    Warth, Benedikt; Sulyok, Michael; Fruhmann, Philipp; Mikula, Hannes; Berthiller, Franz; Schuhmacher, Rainer; Hametner, Christian; Abia, Wilfred Angie; Adam, Gerhard; Fröhlich, Johannes; Krska, Rudolf

    2012-07-15

    Mycotoxins regularly occur in food worldwide and pose serious health risks to consumers. Since individuals can be exposed to a variety of these toxic secondary metabolites of fungi at the same time, there is a demand for proper analytical methods to assess human exposure by suitable biomarkers. This study reports on the development of a liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for the quantitative measurement of 15 mycotoxins and key metabolites in human urine using polarity switching. Deoxynivalenol (DON), DON-3-O-glucuronide, DON-15-O-glucuronide (D15GlcA), de-epoxy DON, nivalenol (NIV), T-2 toxin, HT-2 toxin, zearalenone, zearalenone-14-O-glucuronide, α- and β-zearalenol, fumonisins B(1) and B(2) (FB(1), FB(2)), ochratoxin A (OTA) and aflatoxin M(1) (AFM(1)) were determined without the need for any cleanup using a rapid and simple dilute and shoot approach. Validation was performed in the range of 0.005-40 µg L(-1) depending on the analyte and expected urinary concentration levels. Apparent recoveries between 78 and 119% and interday precisions of 2-17% relative standard deviation (RSD) were achieved. The applicability of the method was demonstrated by the analysis of urine samples obtained from Cameroon. In naturally contaminated urine samples up to six biomarkers of exposure (AFM(1), DON, D15GlcA, NIV, FB(1), and OTA) were detected simultaneously. We conclude that the developed LC/MS/MS method is well suited to quantify multiple mycotoxin biomarkers in human urine down to the sub-ppb range within 18 min and without any prior cleanup. The co-occurrence of several mycotoxins in the investigated samples clearly emphasizes the great potential and importance of this method to assess exposure of humans and animals to naturally occurring mycotoxins. Copyright © 2012 John Wiley & Sons, Ltd.

  15. A simple LC-MS/MS method facilitated by salting-out assisted liquid-liquid extraction to simultaneously determine trans-resveratrol and its glucuronide and sulfate conjugates in rat plasma and its application to pharmacokinetic assay.

    Science.gov (United States)

    Qiu, Zhixia; Yu, Jiaojiao; Dai, Yu; Yang, Yue; Lu, Xiaoyu; Xu, Jiaqiu; Qin, Zhiying; Huang, Fang; Li, Ning

    2017-11-01

    A simple LC-MS/MS method facilitated by salting-out assisted liquid-liquid extraction (SALLE) was applied to simultaneously investigate the pharmacokinetics of trans-resveratrol (Res) and its major glucuronide and sulfate conjugates in rat plasma. Acetonitrile-methanol (80:20, v/v) and ammonium acetate (10 mol L -1 ) were used as extractant and salting-out reagent to locate the target analytes in the supernatant after the aqueous and organic phase stratification, then the analytes were determined via gradient elution by LC-MS/MS in negative mode in a single run. The analytical method was validated with good selectivity, acceptable accuracy (>85%) and low variation of precision (extraction efficiency of target glucuronide and sulfate conjugates (>80%). The method was successfully applied to determine Res and its four conjugated metabolites in rat after Res administration (intragastric, 50 mg kg -1 ; intravenous, 10 mg kg -1 ). The systemic exposures to Res conjugates were much higher than those to Res (AUC 0-t , i.v., 7.43 μm h; p.o., 8.31 μm h); Res-3-O-β-d-glucuronide was the major metabolite (AUC 0-t , i.v., 66.1 μm h; p.o., 333.4 μm h). The bioavailability of Res was estimated to be ~22.4%. The reproducible SALLE method simplified the sample preparation, drastically improved the accuracy of the concomitant assay and gave full consideration of extraction recovery to each target analyte in bio-samples. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Development and single-laboratory validation of a UHPLC-MS/MS method for quantitation of microcystins and nodularin in natural water, cyanobacteria, shellfish and algal supplement tablet powders.

    Science.gov (United States)

    Turner, Andrew D; Waack, Julia; Lewis, Adam; Edwards, Christine; Lawton, Linda

    2018-02-01

    A simple, rapid UHPLC-MS/MS method has been developed and optimised for the quantitation of microcystins and nodularin in wide variety of sample matrices. Microcystin analogues targeted were MC-LR, MC-RR, MC-LA, MC-LY, MC-LF, LC-LW, MC-YR, MC-WR, [Asp3] MC-LR, [Dha7] MC-LR, MC-HilR and MC-HtyR. Optimisation studies were conducted to develop a simple, quick and efficient extraction protocol without the need for complex pre-analysis concentration procedures, together with a rapid sub 5min chromatographic separation of toxins in shellfish and algal supplement tablet powders, as well as water and cyanobacterial bloom samples. Validation studies were undertaken on each matrix-analyte combination to the full method performance characteristics following international guidelines. The method was found to be specific and linear over the full calibration range. Method sensitivity in terms of limits of detection, quantitation and reporting were found to be significantly improved in comparison to LC-UV methods and applicable to the analysis of each of the four matrices. Overall, acceptable recoveries were determined for each of the matrices studied, with associated precision and within-laboratory reproducibility well within expected guidance limits. Results from the formalised ruggedness analysis of all available cyanotoxins, showed that the method was robust for all parameters investigated. The results presented here show that the optimised LC-MS/MS method for cyanotoxins is fit for the purpose of detection and quantitation of a range of microcystins and nodularin in shellfish, algal supplement tablet powder, water and cyanobacteria. The method provides a valuable early warning tool for the rapid, routine extraction and analysis of natural waters, cyanobacterial blooms, algal powders, food supplements and shellfish tissues, enabling monitoring labs to supplement traditional microscopy techniques and report toxicity results within a short timeframe of sample receipt. The new

  17. Quantification of pyrrolizidine alkaloids in North American plants and honey by LC-MS: single laboratory validation.

    Science.gov (United States)

    Mudge, Elizabeth M; Jones, A Maxwell P; Brown, Paula N

    2015-01-01

    Pyrrolizidine alkaloids (PAs) are a class of naturally occurring compounds produced by many flowering plants around the World. Their presence as contaminants in food systems has become a significant concern in recent years. For example, PAs are often found as contaminants in honey through pollen transfer. A validated method was developed for the quantification of four pyrrolizidine alkaloids and one pyrrolizidine alkaloid N-oxide in plants and honey grown and produced in British Columbia. The method was optimised for extraction efficiency from the plant materials and then subjected to a single-laboratory validation to assess repeatability, accuracy, selectivity, LOD, LOQ and method linearity. The PA content in plants ranged from1.0 to 307.8 µg/g with repeatability precision between 3.8 and 20.8% RSD. HorRat values were within acceptable limits and ranged from 0.62 to 1.63 for plant material and 0.56-1.82 for honey samples. Method accuracy was determined through spike studies with recoveries ranging from 84.6 to 108.2% from the raw material negative control and from 82.1-106.0 % for the pyrrolizidine alkaloids in corn syrup. Based on the findings in this single-laboratory validation, this method is suitable for the quantitation of lycopsamine, senecionine, senecionine N-oxide, heliosupine and echimidine in common comfrey (Symphytum officinale), tansy ragwort (Senecio jacobaea), blueweed (Echium vulgare) and hound's tongue (Cynoglossum officinale) and for PA quantitation in honey and found that PA contaminants were present at low levels in BC honey.

  18. A QC approach to the determination of day-to-day reproducibility and robustness of LC-MS methods for global metabolite profiling in metabonomics/metabolomics.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Earll, Mark; Wilson, Ian D

    2012-09-01

    An approach to the determination of day-to-day analytical robustness of LC-MS-based methods for global metabolic profiling using a pooled QC sample is presented for the evaluation of metabonomic/metabolomic data. A set of 60 urine samples were repeatedly analyzed on five different days and the day-to-day reproducibility of the data obtained was determined. Multivariate statistical analysis was performed with the aim of evaluating variability and selected peaks were assessed and validated in terms of retention time stability, mass accuracy and intensity. The methodology enables the repeatability/reproducibility of extended analytical runs in large-scale studies to be determined, allowing the elimination of analytical (as opposed to biological) variability, in order to discover true patterns and correlations within the data. The day-to-day variability of the data revealed by this process suggested that, for this particular system, 3 days continuous operation was possible without the need for maintenance and cleaning. Variation was generally based on signal intensity changes over the 7-day period of the study, and was mainly a result of source contamination.

  19. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    OpenAIRE

    Hassib, Sonia T.; Farag, Awatef E.; Elkady, Ehab F.

    2011-01-01

    Simple, accurate and precise reversed-phase liquid chromatographic (LC) and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS) and trimethoprim (TMP) in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm) based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9):acetonitrile:water (25:100:50, v/v/v) at a flow rate of 1...

  20. A proteomics method using immunoaffinity fluorogenic derivatization-liquid chromatography/tandem mass spectrometry (FD-LC-MS/MS) to identify a set of interacting proteins.

    Science.gov (United States)

    Nakata, Katsunori; Saitoh, Ryoichi; Ishigai, Masaki; Imai, Kazuhiro

    2018-02-01

    Biological functions in organisms are usually controlled by a set of interacting proteins, and identifying the proteins that interact is useful for understanding the mechanism of the functions. Immunoprecipitation is a method that utilizes the affinity of an antibody to isolate and identify the proteins that have interacted in a biological sample. In this study, the FD-LC-MS/MS method, which involves fluorogenic derivatization followed by separation and quantification by HPLC and finally identification of proteins by HPLC-tandem mass spectrometry, was used to identify proteins in immunoprecipitated samples, using heat shock protein 90 (HSP90) as a model of an interacting protein in HepaRG cells. As a result, HSC70 protein, which was known to form a complex with HSP90, was isolated, together with three different types of HSP90-beta. The results demonstrated that the proposed immunoaffinity-FD-LC-MS/MS method could be useful for simultaneously detecting and identifying the proteins that interact with a certain protein. Copyright © 2017 John Wiley & Sons, Ltd.

  1. A LC-MS/MS method for the determination of BADGE-related and BFDGE-related compounds in canned fish food samples based on the formation of [M+NH(4)](+) aducts.

    Science.gov (United States)

    Míguez, J; Herrero, C; Quintás, I; Rodríguez, C; Gigosos, P G; Mariz, O C

    2012-12-01

    A new and simple liquid chromatography tandem mass-spectrometry method for the determination of different bisphenol A (BPA) derivatives such as bisphenol A diglycidyl ether (BADGE), bisphenol F diglycidyl ether (BFDGE) and their reaction products with water and hydrochloric acid in different fish food products was developed. The extraction procedure and the chromatographic conditions were optimised for complex food matrices such as fish products. Food samples were homogenised and extracted with a 1:1 solution of acetonitrile-hexane, the solvent was eliminated in a N(2) stream and the extract was reconstituted with 0.5mL of a 0.01M solution of ammonium formate. The sample solution obtained was directly measured by LC-MS/MS without any further purification under the developed conditions. The use of a mobile phase composed by ammonium formate-methanol in a binary gradient mode produced [M+NH(4)](+) aducts for the different BADGEs and BFDGEs. These aduct's fragmentations were employed for the LC-MS/MS quantification of BPA derivatives in canned fish samples. The results of the validation were appropriate: the method was linear for BADGE and its hydrolysed derivatives up to 1000μgkg(-1), for the remaining compounds linearity achieved up to 100μgkg(-1). Quantification limits were in the range 2-10μgkg(-1). RSD (intra and inter-day) was 6-12% and the recovery was comprised between 89% and 109%. Under the optimised conditions, the chromatographic separation was performed in 8min per sample. The method was applied to the determination of BADGE, BFDGE and their reaction products in different samples of canned fish from Spanish origin. Migration results obtained were in compliance with the EU regulations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. LC-filter Resonance Cancellation with DPWM Inverters in Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Vadstrup, Casper; Wang, Xiongfei; Blaabjerg, Frede

    2015-01-01

    Discontinuous PWM methods cannot easily be used in LC-filtered inverters for adjustable speed drives, as it causes resonances in the filter. This paper present a new method to cancel the resonance and compares this method to previously proposed methods. Wide band gap devices are entering the market...

  3. Ontwikkeling van een FAST-LC methode voor een aantal nitrofuranen in vlees en melk

    NARCIS (Netherlands)

    Anonymous,

    1985-01-01

    Door toepassing van het zogenaamde "FAST-LC systeem" kunnen monsters zonder veel manuele handelingen automatisch worden geanalyseerd op nitrofuranen, medicinale stoffen met een breed werkingsspectrum, toegepast tegen infectieziekten bij runderen, varkens en pluimvee. In de Verenigde Staten mogen

  4. Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS

    OpenAIRE

    Joshi, Payal; Bhoir, Suvarna; Bhagwat, A. M.; Vishwanath, K.; Jadhav, R. K.

    2011-01-01

    Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itop...

  5. Development of high-performance chemical isotope labeling LC-MS for profiling the human fecal metabolome.

    Science.gov (United States)

    Xu, Wei; Chen, Deying; Wang, Nan; Zhang, Ting; Zhou, Ruokun; Huan, Tao; Lu, Yingfeng; Su, Xiaoling; Xie, Qing; Li, Liang; Li, Lanjuan

    2015-01-20

    Human fecal samples contain endogenous human metabolites, gut microbiota metabolites, and other compounds. Profiling the fecal metabolome can produce metabolic information that may be used not only for disease biomarker discovery, but also for providing an insight about the relationship of the gut microbiome and human health. In this work, we report a chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS) method for comprehensive and quantitative analysis of the amine- and phenol-containing metabolites in fecal samples. Differential (13)C2/(12)C2-dansyl labeling of the amines and phenols was used to improve LC separation efficiency and MS detection sensitivity. Water, methanol, and acetonitrile were examined as an extraction solvent, and a sequential water-acetonitrile extraction method was found to be optimal. A step-gradient LC-UV setup and a fast LC-MS method were evaluated for measuring the total concentration of dansyl labeled metabolites that could be used for normalizing the sample amounts of individual samples for quantitative metabolomics. Knowing the total concentration was also useful for optimizing the sample injection amount into LC-MS to maximize the number of metabolites detectable while avoiding sample overloading. For the first time, dansylation isotope labeling LC-MS was performed in a simple time-of-flight mass spectrometer, instead of high-end equipment, demonstrating the feasibility of using a low-cost instrument for chemical isotope labeling metabolomics. The developed method was applied for profiling the amine/phenol submetabolome of fecal samples collected from three families. An average of 1785 peak pairs or putative metabolites were found from a 30 min LC-MS run. From 243 LC-MS runs of all the fecal samples, a total of 6200 peak pairs were detected. Among them, 67 could be positively identified based on the mass and retention time match to a dansyl standard library, while 581 and 3197 peak pairs could be putatively

  6. Determination of crenolanib in human serum and cerebrospinal fluid by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS).

    Science.gov (United States)

    Roberts, Michael S; Turner, David C; Owens, Thandranese S; Ramachandran, Abhijit; Wetmore, Cynthia; Throm, Stacy L; Stewart, Clinton F

    2013-06-15

    A LC-ESI-MS/MS method for the determination of crenolanib (CP-868,596) in human serum was developed and validated employing d4-CP-868,596 as an internal standard (ISTD). In addition to human serum, the method was also partially validated for crenolanib determination in human cerebrospinal fluid (CSF) samples. Sample aliquots (50μl of serum or CSF) were prepared for analysis using liquid-liquid extraction (LLE) with tert-butyl methyl ether. Chromatography was performed using a phenomenex Gemini C18 column (3μm, 100mm×4.6mm I.D.) in a column heater set at 50°C and an isocratic mobile phase (methanol/water/formic acid at a volume ratio of 25/25/0.15, v/v/v). The flow rate was 0.45mL/min, and the retention time for both analyte and ISTD was less than 3.5min. Samples were analyzed with an API-5500 LC-MS/MS system (ESI) in positive ionization mode coupled to a Shimadzu HPLC system. The ion transitions monitored were m/z 444.4→373.1 and m/z 448.2→374.2 for crenolanib and ISTD, respectively. The method was linear over the range of 5-1000ng/mL for serum and 0.5-1000ng/mL for CSF. For human serum, both intra-day and inter-day precision were <4%, while intra-day and inter-day accuracy were within 8% of nominal values. Recovery was greater than 50% for both the analyte and ISTD. For CSF samples, both intra-day and inter-day precision were <9% except at the lower limit of quantification (LLOQ) which was <17%. The intra-day and inter-day accuracy were within 11% of the nominal CSF concentrations. After validation, this method was successfully applied to the analysis of serial pharmacokinetic samples obtained from a child treated with oral crenolanib. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Simultaneous LC-MS/MS determination of phenylbutyrate, phenylacetate benzoate and their corresponding metabolites phenylacetylglutamine and hippurate in blood and urine.

    Science.gov (United States)

    Laryea, Maurice D; Herebian, Diran; Meissner, Thomas; Mayatepek, Ertan

    2010-12-01

    Inborn errors of urea metabolism result in hyperammonemia. Treatment of urea cycle disorders can effectively lower plasma ammonium levels and results in survival in the majority of patients. Available medications for treating urea cycle disorders include sodium benzoate (BA), sodium phenylacetate (PAA), and sodium phenylbutyrate (PBA) and are given to provide alternate routes for disposition of waste nitrogen excretion. In this study, we develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of benzoic acid, phenylacetic acid, phenylbutyric acid, phenylacetylglutamine, and hippuric acid in plasma and urine from children with inborn errors of urea synthesis. Plasma extracts and diluted urine samples were injected on a reverse-phase column and identified and quantified by selected reaction monitoring (SRM) in negative ion mode. Deuterated analogues served as internal standards. Analysis time was 7 min. Assay precision, accuracy, and linearity and sample stability were determined using enriched samples. Quantification limits of the method were 100 ng/ml (0.3-0.8 μmol/L) for all analytes, and recoveries were >90%. Inter- and intraday relative standard deviations were <10%. Our newly developed LC-MS/MS represents a robust, sensitive, and rapid method that allows simultaneous determination of the five compounds in plasma and urine.

  8. Development and validation of a sensitive LC-MS-MS method for the simultaneous determination of multicomponent contents in artificial Calculus Bovis.

    Science.gov (United States)

    Peng, Can; Tian, Jixin; Lv, Mengying; Huang, Yin; Tian, Yuan; Zhang, Zunjian

    2014-02-01

    Artificial Calculus Bovis is a major substitute in clinical treatment for Niuhuang, a widely used, efficacious but rare traditional Chinese medicine. However, its chemical structures and the physicochemical properties of its components are complicated, which causes difficulty in establishing a set of effective and comprehensive methods for its identification and quality control. In this study, a simple, sensitive and reliable liquid chromatography-tandem mass spectrometry method was successfully developed and validated for the simultaneous determination of bilirubin, taurine and major bile acids (including six unconjugated bile acids, two glycine-conjugated bile acids and three taurine-conjugated bile acids) in artificial Calculus Bovis using a Zorbax SB-C18 column with a gradient elution of methanol and 10 mmol/L ammonium acetate in aqueous solution (adjusted to pH 3.0 with formic acid). The mass spectra were obtained in the negative ion mode using dehydrocholic acid as the internal standard. The content of each analyte in artificial Calculus Bovis was determined by monitoring specific ion pairs in the selected reaction monitoring mode. All analytes demonstrated perfect linearity (r(2) > 0.994) in a wide dynamic range, and 10 batches of samples from different sources were further analyzed. This study provided a comprehensive method for the quality control of artificial Calculus Bovis.

  9. Dual quantification of dapivirine and maraviroc in cervicovaginal secretions from ophthalmic tear strips and polyester-based swabs via liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis.

    Science.gov (United States)

    Parsons, Teresa L; Emory, Joshua F; Seserko, Lauren A; Aung, Wutyi S; Marzinke, Mark A

    2014-09-01

    Topical microbicidal agents are being actively pursued as a modality to prevent HIV viral transmission during sexual intercourse. Quantification of antiretroviral agents in specimen sources where antiviral activity is elicited is critical, and drug measurements in cervicovaginal fluid can provide key information on local drug concentrations. Two antiretroviral drugs, dapivirine and maraviroc, have gained interest as vaginal microbicidal agents, and rugged methods are required for their quantification in cervicovaginal secretions. Cervicovaginal fluid spiked with dapivirine and maraviroc were applied to ophthalmic tear strips or polyester-based swabs to mimic collection procedures used in clinical studies. Following sample extraction and the addition of isotopically labeled internal standards, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis using a Waters BEH C8, 50mm×2.1mm, 1.7μm particle size column, on an API 4000 mass analyzer operated in selective reaction monitoring mode. The method was validated according to FDA Bioanalytical Method Validation guidelines. Due to the disparate saturation capacity of the tested collection devices, the analytical measuring ranges for dapivirine and maravirocin cervicovaginal fluid on the ophthalmic tear strip were 0.05-25ng/tear strip, and 0.025-25ng/tear strip, respectively. As for the polyester-based swab, the analytical measuring ranges were 0.25-125ng/swab for dapivirine and 0.125-125ng/swab for maraviroc. Dilutional studies were performed for both analytes to extended ranges of 25,000ng/tear strip and 11,250ng/swab. Standard curves were generated via weighted (1/x(2)) linear or quadratic regression of calibrators. Precision, accuracy, stability and matrix effects studies were all performed and deemed acceptable according to the recommendations of the FDA Bioanalytical Method Validation guidelines. A rugged LC-MS/MS method for the dual quantification of dapivirine and

  10. Saving time and money: a validation of the self ratings on the prospective NIMH Life-Chart Method (NIMH-LCM).

    Science.gov (United States)

    Born, Christoph; Amann, Benedikt L; Grunze, Heinz; Post, Robert M; Schärer, Lars

    2014-05-07

    Careful observation of the longitudinal course of bipolar disorders is pivotal to finding optimal treatments and improving outcome. A useful tool is the daily prospective Life-Chart Method, developed by the National Institute of Mental Health. However, it remains unclear whether the patient version is as valid as the clinician version. We compared the patient-rated version of the Lifechart (LC-self) with the Young-Mania-Rating Scale (YMRS), Inventory of Depressive Symptoms-Clinician version (IDS-C), and Clinical Global Impression-Bipolar version (CGI-BP) in 108 bipolar I and II patients who participated in the Naturalistic Follow-up Study (NFS) of the German centres of the Bipolar Collaborative Network (BCN; formerly Stanley Foundation Bipolar Network). For statistical evaluation, levels of severity of mood states on the Lifechart were transformed numerically and comparison with affective scales was performed using chi-square and t tests. For testing correlations Pearson´s coefficient was calculated. Ratings for depression of LC-self and total scores of IDS-C were found to be highly correlated (Pearson coefficient r = -.718; p money saving alternative to the clinician-rated version which should be incorporated in future clinical research in bipolar disorder. Generalizability of the results is limited by the selection of highly motivated patients in specialized bipolar centres and by the open design of the study.

  11. Isotope ratio monitoring LC/MS (IRM-LC/MS): new applications

    International Nuclear Information System (INIS)

    Juchelka, D; Hilkert, A.; Krummen, M.

    2005-01-01

    With the introduction of compound specific isotope analysis by isotope ratio monitoring GC/ MS (IRM-GC/MS) the immediate demand for similar applications using HPLC was created. Many compounds of biological, medical, pharmaceutical and environmental interest are not volatile or too polar. Consequently, they cannot be directly analyzed by gas chromatography. In IRM-GC/MS the carrier is helium, which does not interfere with the essential combust ion step prior to isotope ratio mass spectrometry (IRMS). In opposite the LC mobile phase has inhibited a similar direct conversion up to now. All earlier IRM-LC/MS approaches were based on the removal of the liquid phase prior to combustion risking fractionation of the isotope ratios of the eluted compounds. To avoid such restrictions we developed a new continuous flow concept for the coupling of an HPLC system to the isotope ratio MS for 13 C/ 12C isotope ratio analysis. In the Finnigan LC IsoLink, the liquid phase is not removed from the sample prior to oxidation. The sample is oxidized still in the mobile phase followed by on-line separation of the CO 2 from the liquid phase and transfer into the isotope ratio MS. Therefore, this strategy is based on water and inorganic buffers as mobile phase. The new approach opens up a whole new world in the application of gas isotope ratio mass spectrometry. The 13 C/ 12 C ratio s of organic acids, amino acids, carbohydrates and nucleotides can now be measured. These components typically within a complex matrix are separated by liquid chromatography followed by on-line determination of the isotope ratios. The draw backs of using derivatization and off-line preparation procedures can now be over come. This new technique allow s studying biochemical cycles, running tracer experiments and determining the origin of components. Applications from different scientific areas such as biogeochemistry, molecular biology, and pharmacy as well as authenticity control o f foods will be presented

  12. Label-Free, LC-MS-Based Assays to Quantitate Small-Molecule Antagonist Binding to the Mammalian BLT1 Receptor.

    Science.gov (United States)

    Chen, Xun; Stout, Steven; Mueller, Uwe; Boykow, George; Visconti, Richard; Siliphaivanh, Phieng; Spencer, Kerrie; Presland, Jeremy; Kavana, Michael; Basso, Andrea D; McLaren, David G; Myers, Robert W

    2017-08-01

    We have developed and validated label-free, liquid chromatography-mass spectrometry (LC-MS)-based equilibrium direct and competition binding assays to quantitate small-molecule antagonist binding to recombinant human and mouse BLT1 receptors expressed in HEK 293 cell membranes. Procedurally, these binding assays involve (1) equilibration of the BLT1 receptor and probe ligand, with or without a competitor; (2) vacuum filtration through cationic glass fiber filters to separate receptor-bound from free probe ligand; and (3) LC-MS analysis in selected reaction monitoring mode for bound probe ligand quantitation. Two novel, optimized probe ligands, compounds 1 and 2, were identified by screening 20 unlabeled BLT1 antagonists for direct binding. Saturation direct binding studies confirmed the high affinity, and dissociation studies established the rapid binding kinetics of probe ligands 1 and 2. Competition binding assays were established using both probe ligands, and the affinities of structurally diverse BLT1 antagonists were measured. Both binding assay formats can be executed with high specificity and sensitivity and moderate throughput (96-well plate format) using these approaches. This highly versatile, label-free method for studying ligand binding to membrane-associated receptors should find broad application as an alternative to traditional methods using labeled ligands.

  13. G2LC: Resources Autoscaling for Real Time Bioinformatics Applications in IaaS

    Directory of Open Access Journals (Sweden)

    Rongdong Hu

    2015-01-01

    Full Text Available Cloud computing has started to change the way how bioinformatics research is being carried out. Researchers who have taken advantage of this technology can process larger amounts of data and speed up scientific discovery. The variability in data volume results in variable computing requirements. Therefore, bioinformatics researchers are pursuing more reliable and efficient methods for conducting sequencing analyses. This paper proposes an automated resource provisioning method, G2LC, for bioinformatics applications in IaaS. It enables application to output the results in a real time manner. Its main purpose is to guarantee applications performance, while improving resource utilization. Real sequence searching data of BLAST is used to evaluate the effectiveness of G2LC. Experimental results show that G2LC guarantees the application performance, while resource is saved up to 20.14%.

  14. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  15. Practical procedure for method validation in INAA- A tutorial

    International Nuclear Information System (INIS)

    Petroni, Robson; Moreira, Edson G.

    2015-01-01

    This paper describes the procedure employed by the Neutron Activation Laboratory at the Nuclear and Energy Research Institute (LAN, IPEN - CNEN/SP) for validation of Instrumental Neutron Activation Analysis (INAA) methods. According to recommendations of ISO/IEC 17025 the method performance characteristics (limit of detection, limit of quantification, trueness, repeatability, intermediate precision, reproducibility, selectivity, linearity and uncertainties budget) were outline in an easy, fast and convenient way. The paper presents step by step how to calculate the required method performance characteristics in a process of method validation, what are the procedures, adopted strategies and acceptance criteria for the results, that is, how to make a method validation in INAA. In order to exemplify the methodology applied, obtained results for the method validation of mass fraction determination of Co, Cr, Fe, Rb, Se and Zn in biological matrix samples, using an internal reference material of mussel tissue were presented. It was concluded that the methodology applied for validation of INAA methods is suitable, meeting all the requirements of ISO/IEC 17025, and thereby, generating satisfactory results for the studies carried at LAN, IPEN - CNEN/SP. (author)

  16. Practical procedure for method validation in INAA- A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Petroni, Robson; Moreira, Edson G., E-mail: robsonpetroni@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This paper describes the procedure employed by the Neutron Activation Laboratory at the Nuclear and Energy Research Institute (LAN, IPEN - CNEN/SP) for validation of Instrumental Neutron Activation Analysis (INAA) methods. According to recommendations of ISO/IEC 17025 the method performance characteristics (limit of detection, limit of quantification, trueness, repeatability, intermediate precision, reproducibility, selectivity, linearity and uncertainties budget) were outline in an easy, fast and convenient way. The paper presents step by step how to calculate the required method performance characteristics in a process of method validation, what are the procedures, adopted strategies and acceptance criteria for the results, that is, how to make a method validation in INAA. In order to exemplify the methodology applied, obtained results for the method validation of mass fraction determination of Co, Cr, Fe, Rb, Se and Zn in biological matrix samples, using an internal reference material of mussel tissue were presented. It was concluded that the methodology applied for validation of INAA methods is suitable, meeting all the requirements of ISO/IEC 17025, and thereby, generating satisfactory results for the studies carried at LAN, IPEN - CNEN/SP. (author)

  17. Validation of the Rotation Ratios Method

    International Nuclear Information System (INIS)

    Foss, O.A.; Klaksvik, J.; Benum, P.; Anda, S.

    2007-01-01

    Background: The rotation ratios method describes rotations between pairs of sequential pelvic radiographs. The method seems promising but has not been validated. Purpose: To validate the accuracy of the rotation ratios method. Material and Methods: Known pelvic rotations between 165 radiographs obtained from five skeletal pelvises in an experimental material were compared with the corresponding calculated rotations to describe the accuracy of the method. The results from a clinical material of 262 pelvic radiographs from 46 patients defined the ranges of rotational differences compared. Repeated analyses, both on the experimental and the clinical material, were performed using the selected reference points to describe the robustness and the repeatability of the method. Results: The reference points were easy to identify and barely influenced by pelvic rotations. The mean differences between calculated and real pelvic rotations were 0.0 deg (SD 0.6) for vertical rotations and 0.1 deg (SD 0.7) for transversal rotations in the experimental material. The intra- and interobserver repeatability of the method was good. Conclusion: The accuracy of the method was reasonably high, and the method may prove to be clinically useful

  18. The patient education - Learning and Coping Strategies - improves adherence in cardiac rehabilitation (LC-REHAB)

    DEFF Research Database (Denmark)

    Lynggaard, Vibeke; Nielsen, Claus Vinther; Zwisler, Ann-Dorthe

    2017-01-01

    BACKGROUND: Despite proven benefits of cardiac rehabilitation (CR), adherence to CR remains suboptimal. This trial aimed to assess the impact of the patient education 'Learning and Coping Strategies' (LC) on patient adherence to an eight-week CR program. METHODS: 825 patients with ischaemic heart...... and education. Patients with heart failure, low levels of education and household income appear to benefit most from this adherence promoting intervention. TRIAL REGISTRATION: www.clinicaltrials.gov identifier NCT01668394....... disease or heart failure were open label randomised to either the LC arm (LC plus CR) or the control arm (CR alone) across three hospital units in Denmark. Both arms received same amount of training and education hours. LC consisted of individual clarifying interviews, participation of experienced...

  19. The Method of Manufactured Universes for validating uncertainty quantification methods

    KAUST Repository

    Stripling, H.F.; Adams, M.L.; McClarren, R.G.; Mallick, B.K.

    2011-01-01

    The Method of Manufactured Universes is presented as a validation framework for uncertainty quantification (UQ) methodologies and as a tool for exploring the effects of statistical and modeling assumptions embedded in these methods. The framework

  20. Keefektifan Model Pembelajaran LC 5E Dan TSTS Berbantuan LKPD Terhadap Hasil Belajar

    Directory of Open Access Journals (Sweden)

    Ririn Asmawati

    2014-06-01

    Full Text Available AbstrakTujuan penelitian ini adalah untuk mengetahui apakah hasil belajar pada pembelajaran Learning Cycle 5E (LC 5E dan kooperatif Two Stay Two Stray (TSTS berbantuan LKPD dapat mencapai KKM yang ditetapkan sekolah; untuk mengetahui apakah rata-rata hasil belajar pada pembelajaran LC 5E dan TSTS berbantuan LKPD lebih tinggi daripada pem-belajaran ekspositori, serta apakah rata-rata hasil belajar pada pembelajaran LC 5E berban-tuan LKPD lebih baik daripada pembelajaran TSTS berbantuan LKPD. Data penelitian diperoleh dengan metode tes dan observasi. Analisis data hasil belajar meliputi uji nor-malitas, uji homogenitas, uji perbedaan rata-rata, uji scheffe, dan uji proporsi. Hasil pene-litian menunjukkan bahwa hasil belajar pada pembelajaran LC 5E berbantuan LKPD telah mencapai KKM, sedangkan hasil belajar pada pembelajaran TSTS berbantuan LKPD dan pembelajaran ekspositori belum mencapai KKM. Selain itu, rata-rata hasil belajar pada pembelajaran LC 5E dan TSTS berbantuan LKPD lebih tinggi daripada pembelajaran eks-positori, sedangkan rata-rata hasil belajar pada pembelajaran LC 5E berbantuan LKPD le-bih baik daripada pembelajaran TSTS berbantuan LKPD. Kata kunci:       hasil belajar; LC 5E; TSTS  AbstractThe purposes of this research are to find out whether the learning outcomes in the Learning Cycle 5E (LC 5E and the cooperative Two Stay Two Stray (TSTS assisted LKPD may attain the KKM settled by the school; to find out whether the average of the learning outcome in the LC 5E and TSTS assisted LKPD is higher than the expository learning, and whether the average of the learning outcome in the LC 5E assisted LKPD is better than TSTS assisted LKPD. The data of the research were obtained by testing and observation methods. The data analysis of learning outcomes included normality test, homogeneity test, mean difference test, Scheffe test, and proportions test. The research outcome indicated that the learning outcome in the implementation of

  1. Application of survival analysis methodology to the quantitative analysis of LC-MS proteomics data.

    Science.gov (United States)

    Tekwe, Carmen D; Carroll, Raymond J; Dabney, Alan R

    2012-08-01

    Protein abundance in quantitative proteomics is often based on observed spectral features derived from liquid chromatography mass spectrometry (LC-MS) or LC-MS/MS experiments. Peak intensities are largely non-normal in distribution. Furthermore, LC-MS-based proteomics data frequently have large proportions of missing peak intensities due to censoring mechanisms on low-abundance spectral features. Recognizing that the observed peak intensities detected with the LC-MS method are all positive, skewed and often left-censored, we propose using survival methodology to carry out differential expression analysis of proteins. Various standard statistical techniques including non-parametric tests such as the Kolmogorov-Smirnov and Wilcoxon-Mann-Whitney rank sum tests, and the parametric survival model and accelerated failure time-model with log-normal, log-logistic and Weibull distributions were used to detect any differentially expressed proteins. The statistical operating characteristics of each method are explored using both real and simulated datasets. Survival methods generally have greater statistical power than standard differential expression methods when the proportion of missing protein level data is 5% or more. In particular, the AFT models we consider consistently achieve greater statistical power than standard testing procedures, with the discrepancy widening with increasing missingness in the proportions. The testing procedures discussed in this article can all be performed using readily available software such as R. The R codes are provided as supplemental materials. ctekwe@stat.tamu.edu.

  2. Method development and validation for the simultaneous determination of organochlorine and organophosphorus pesticides in a complex sediment matrix.

    Science.gov (United States)

    Alcántara-Concepción, Victor; Cram, Silke; Gibson, Richard; Ponce de León, Claudia; Mazari-Hiriart, Marisa

    2013-01-01

    The Xochimilco area in the southeastern part of Mexico City has a variety of socioeconomic activities, such as periurban agriculture, which is of great importance in the Mexico City metropolitan area. Pesticides are used extensively, some being legal, mostly chlorpyrifos and malathion, and some illegal, mostly DDT. Sediments are a common sink for pesticides in aquatic systems near agricultural areas, and Xochimilco sediments have a complex composition with high contents of organic matter and clay that are ideal adsorption sites for organochlorine (OC) and organophosphorus (OP) pesticides. Therefore, it is important to have a quick, affordable, and reliable method to determine these pesticides. Conventional methods for the determination of OC and OP pesticides are long, laborious, and costly owing to the high volume of solvents and adsorbents. The present study developed and validated a method for determining 18 OC and five OP pesticides in sediments with high organic and clay contents. In contrast with other methods described in the literature, this method allows isolation of the 23 pesticides with a 12 min microwave-assisted extraction (MAE) and one-step cleanup of pesticides. The method developed is a simpler, time-saving procedure that uses only 3.5 g of dry sediment. The use of MAE eliminates excessive handling and the possible loss of analytes. It was shown that the use of LC-Si cartridges with hexane-ethyl acetate (75+25, v/v) in the cleanup procedure recovered all pesticides with rates between 70 and 120%. The validation parameters demonstrated good performance of the method, with intermediate precision ranging from 7.3 to 17.0%, HorRat indexes all below 0.5, and tests of accuracy with the 23 pesticides at three concentration levels demonstrating recoveries ranging from 74 to 114% and RSDs from 3.3 to 12.7%.

  3. LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

    Science.gov (United States)

    Zuwei, Wang; Boyd, Jason; Berens, Kurt L.; Putcha, Lakshmi

    2004-01-01

    Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

  4. Method validation in pharmaceutical analysis: from theory to practical optimization

    Directory of Open Access Journals (Sweden)

    Jaqueline Kaleian Eserian

    2015-01-01

    Full Text Available The validation of analytical methods is required to obtain high-quality data. For the pharmaceutical industry, method validation is crucial to ensure the product quality as regards both therapeutic efficacy and patient safety. The most critical step in validating a method is to establish a protocol containing well-defined procedures and criteria. A well planned and organized protocol, such as the one proposed in this paper, results in a rapid and concise method validation procedure for quantitative high performance liquid chromatography (HPLC analysis.   Type: Commentary

  5. Validation of NAA Method for Urban Particulate Matter

    International Nuclear Information System (INIS)

    Woro Yatu Niken Syahfitri; Muhayatun; Diah Dwiana Lestiani; Natalia Adventini

    2009-01-01

    Nuclear analytical techniques have been applied in many countries for determination of environmental pollutant. Method of NAA (neutron activation analysis) representing one of nuclear analytical technique of that has low detection limits, high specificity, high precision, and accuracy for large majority of naturally occurring elements, and ability of non-destructive and simultaneous determination of multi-elemental, and can handle small sample size (< 1 mg). To ensure quality and reliability of the method, validation are needed to be done. A standard reference material, SRM NIST 1648 Urban Particulate Matter, has been used to validate NAA method. Accuracy and precision test were used as validation parameters. Particulate matter were validated for 18 elements: Ti, I, V, Br, Mn, Na, K, Cl, Cu, Al, As, Fe, Co, Zn, Ag, La, Cr, and Sm,. The result showed that the percent relative standard deviation of the measured elemental concentrations are found to be within ranged from 2 to 14,8% for most of the elements analyzed whereas Hor rat value in range 0,3-1,3. Accuracy test results showed that relative bias ranged from -11,1 to 3,6%. Based on validation results, it can be stated that NAA method is reliable for characterization particulate matter and other similar matrix samples to support air quality monitoring. (author)

  6. Validation of a confirmatory method for the determination of melamine in egg by gas chromatography-mass spectrometry and ultra-performance liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Xia Xi; Ding Shuangyang; Li Xiaowei; Gong Xiao; Zhang Suxia; Jiang Haiyang; Li Jiancheng; Shen Jianzhong

    2009-01-01

    A sensitive and reliable method was developed and validated for detection and confirmation of melamine in egg based on gas chromatography-mass spectrometry (GC-MS) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Trichloroacetic acid solution was used for sample extraction and precipitation of proteins. The aqueous extracts were subjected to solid-phase extraction by mixed-mode reversed-phase/strong cation-exchange cartridges. Using ultra-performance liquid chromatography and electrospray ionization in the positive ion mode, melamine was determined by LC-MS/MS, which was completed in 5 min for each injection. For the GC-MS analysis, extracted melamine was derivatized with N,O-bis(trimethylsilyl)trifluoracetamide prior to selected ion monitoring detection in electron impact mode. The average recovery of melamine from fortified samples ranged from 85.2% to 103.2%, with coefficients of variation lower than 12%. The limit of detection obtained by GC-MS and UPLC-MS/MS was 10 and 5 μg kg -1 , respectively. This validated method was successfully applied to the determination of melamine in real samples from market.

  7. BMAA extraction of cyanobacteria samples: which method to choose?

    Science.gov (United States)

    Lage, Sandra; Burian, Alfred; Rasmussen, Ulla; Costa, Pedro Reis; Annadotter, Heléne; Godhe, Anna; Rydberg, Sara

    2016-01-01

    β-N-Methylamino-L-alanine (BMAA), a neurotoxin reportedly produced by cyanobacteria, diatoms and dinoflagellates, is proposed to be linked to the development of neurological diseases. BMAA has been found in aquatic and terrestrial ecosystems worldwide, both in its phytoplankton producers and in several invertebrate and vertebrate organisms that bioaccumulate it. LC-MS/MS is the most frequently used analytical technique in BMAA research due to its high selectivity, though consensus is lacking as to the best extraction method to apply. This study accordingly surveys the efficiency of three extraction methods regularly used in BMAA research to extract BMAA from cyanobacteria samples. The results obtained provide insights into possible reasons for the BMAA concentration discrepancies in previous publications. In addition and according to the method validation guidelines for analysing cyanotoxins, the TCA protein precipitation method, followed by AQC derivatization and LC-MS/MS analysis, is now validated for extracting protein-bound (after protein hydrolysis) and free BMAA from cyanobacteria matrix. BMAA biological variability was also tested through the extraction of diatom and cyanobacteria species, revealing a high variance in BMAA levels (0.0080-2.5797 μg g(-1) DW).

  8. Validation of method in instrumental NAA for food products sample

    International Nuclear Information System (INIS)

    Alfian; Siti Suprapti; Setyo Purwanto

    2010-01-01

    NAA is a method of testing that has not been standardized. To affirm and confirm that this method is valid. it must be done validation of the method with various sample standard reference materials. In this work. the validation is carried for food product samples using NIST SRM 1567a (wheat flour) and NIST SRM 1568a (rice flour). The results show that the validation method for testing nine elements (Al, K, Mg, Mn, Na, Ca, Fe, Se and Zn) in SRM 1567a and eight elements (Al, K, Mg, Mn, Na, Ca, Se and Zn ) in SRM 1568a pass the test of accuracy and precision. It can be conclude that this method has power to give valid result in determination element of the food products samples. (author)

  9. Human Factors methods concerning integrated validation of nuclear power plant control rooms; Metodutveckling foer integrerad validering

    Energy Technology Data Exchange (ETDEWEB)

    Oskarsson, Per-Anders; Johansson, Bjoern J.E.; Gonzalez, Natalia (Swedish Defence Research Agency, Information Systems, Linkoeping (Sweden))

    2010-02-15

    The frame of reference for this work was existing recommendations and instructions from the NPP area, experiences from the review of the Turbic Validation and experiences from system validations performed at the Swedish Armed Forces, e.g. concerning military control rooms and fighter pilots. These enterprises are characterized by complex systems in extreme environments, often with high risks, where human error can lead to serious consequences. A focus group has been performed with representatives responsible for Human Factors issues from all Swedish NPP:s. The questions that were discussed were, among other things, for whom an integrated validation (IV) is performed and its purpose, what should be included in an IV, the comparison with baseline measures, the design process, the role of SSM, which methods of measurement should be used, and how the methods are affected of changes in the control room. The report brings different questions to discussion concerning the validation process. Supplementary methods of measurement for integrated validation are discussed, e.g. dynamic, psychophysiological, and qualitative methods for identification of problems. Supplementary methods for statistical analysis are presented. The study points out a number of deficiencies in the validation process, e.g. the need of common guidelines for validation and design, criteria for different types of measurements, clarification of the role of SSM, and recommendations for the responsibility of external participants in the validation process. The authors propose 12 measures for taking care of the identified problems

  10. A liquid chromatography-mass spectrometric method for the determination of oak moss allergens atranol and chloroatranol in perfumes

    DEFF Research Database (Denmark)

    Bossi, Rossana; Rastogi, Suresh Chandra; Bernard, Guillaume

    2004-01-01

    This paper describes a validated liquid chromatographic-tandem mass spectrometric method for quantitative analysis of the potential oak moss allergens atranol and chloroatranol in perfumes and similar products. The method employs LC-MS-MS with electrospray ionization (ESI) in negative mode...

  11. LC-MS/MS methods for albendazole analysis in feed and its metabolite residues in fish fillet and a leaching study in feed after an alternative procedure for drug incorporation.

    Science.gov (United States)

    Busatto, Zenaís; da Silva, Agnaldo Fernando Baldo; de Freitas, Osvaldo; Paschoal, Jonas Augusto Rizzato

    2017-04-01

    This paper describes the development of analytical methods for the quantification of albendazole (ABZ) in fish feed and ABZ and its main known metabolites (albendazole sulfoxide, albendazole sulfone and albendazole aminosulfone) in fish fillet employing LC-MS/MS. In order to assess the reliability of the analytical methods, evaluation was undertaken as recommended by related guides proposed by the Brazilian Ministry of Agriculture for analytical method validation. The calibration curve for ABZ quantification in feed showed adequate linearity (r > 0.99), precision (CV  0.99) for all analytes, precision (CV < 13%) and trueness around 100%, with CCα < 122 ng g - 1 and CCβ < 145 ng g - 1 . Besides, by aiming to avoid the risk of ABZ leaching from feed into the aquatic environment during fish medication via the oral route, a promising procedure for drug incorporation in the feed involving coating feed pellets with ethyl cellulose polymer containing ABZ was also evaluated. The medicated feed had good homogeneity (CV < 3%) and a lower release of ABZ (< 0.2%) from feed to water when the medicated feed stayed in the water for up to 15 min.

  12. Cross-validated stable-isotope dilution GC-MS and LC-MS/MS assays for monoacylglycerol lipase (MAGL) activity by measuring arachidonic acid released from the endocannabinoid 2-arachidonoyl glycerol.

    Science.gov (United States)

    Kayacelebi, Arslan Arinc; Schauerte, Celina; Kling, Katharina; Herbers, Jan; Beckmann, Bibiana; Engeli, Stefan; Jordan, Jens; Zoerner, Alexander A; Tsikas, Dimitrios

    2017-03-15

    2-Arachidonoyl glycerol (2AG) is an endocannabinoid that activates cannabinoid (CB) receptors CB1 and CB2. Monoacylglycerol lipase (MAGL) inactivates 2AG through hydrolysis to arachidonic acid (AA) and glycerol, thus modulating the activity at CB receptors. In the brain, AA released from 2AG by the action of MAGL serves as a substrate for cyclooxygenases which produce pro-inflammatory prostaglandins. Here we report stable-isotope GC-MS and LC-MS/MS assays for the reliable measurement of MAGL activity. The assays utilize deuterium-labeled 2AG (d 8 -2AG; 10μM) as the MAGL substrate and measure deuterium-labeled AA (d 8 -AA; range 0-1μM) as the MAGL product. Unlabelled AA (d 0 -AA, 1μM) serves as the internal standard. d 8 -AA and d 0 -AA are extracted from the aqueous buffered incubation mixtures by ethyl acetate. Upon solvent evaporation the residue is reconstituted in the mobile phase prior to LC-MS/MS analysis or in anhydrous acetonitrile for GC-MS analysis. LC-MS/MS analysis is performed in the negative electrospray ionization mode by selected-reaction monitoring the mass transitions [M-H] - →[M-H - CO 2 ] - , i.e., m/z 311→m/z 267 for d 8 -AA and m/z 303→m/z 259 for d 0 -AA. Prior to GC-MS analysis d 8 -AA and d 0 -AA were converted to their pentafluorobenzyl (PFB) esters by means of PFB-Br. GC-MS analysis is performed in the electron-capture negative-ion chemical ionization mode by selected-ion monitoring the ions [M-PFB] - , i.e., m/z 311 for d 8 -AA and m/z 303 for d 0 -AA. The GC-MS and LC-MS/MS assays were cross-validated. Linear regression analysis between the concentration (range, 0-1μM) of d 8 -AA measured by LC-MS/MS (y) and that by GC-MS (x) revealed a straight line (r 2 =0.9848) with the regression equation y=0.003+0.898x, indicating a good agreement. In dog liver, we detected MAGL activity that was inhibitable by the MAGL inhibitor JZL-184. Exogenous eicosatetraynoic acid is suitable as internal standard for the quantitative determination

  13. Metabolic profiling of roots of liquorice (Glycyrrhiza glabra) from different geographical areas by ESI/MS/MS and determination of major metabolites by LC-ESI/MS and LC-ESI/MS/MS.

    Science.gov (United States)

    Montoro, Paola; Maldini, Mariateresa; Russo, Mariateresa; Postorino, Santo; Piacente, Sonia; Pizza, Cosimo

    2011-02-20

    Liquid chromatography electrospray mass spectrometry (LC-ESI/MS) has been applied to the full characterization of saponins and phenolics in hydroalcoholic extracts of roots of liquorice (Glycyrrhiza glabra). Relative quantitative analyses of the samples with respect to the phenolic constituents and to a group of saponins related to glycyrrhizic acid were performed using LC-ESI/MS. For the saponin constituents, full scan LC-MS/MS fragmentation of the protonated (positive ion mode) or deprotonated (negative ion mode) molecular species generated diagnostic fragment ions that provided information concerning the triterpene skeleton and the number and nature of the substituents. On the basis of the specific fragmentation of glycyrrhizic acid, an LC-MS/MS method was developed in order to quantify the analyte in the liquorice root samples. Chinese G. glabra roots contained the highest levels of glycyrrhizic acid, followed by those from Italy (Calabria). Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Analytical methodologies based on LC-MS/MS for monitoring selected emerging compounds in liquid and solid phases of the sewage sludge.

    Science.gov (United States)

    Boix, C; Ibáñez, M; Fabregat-Safont, D; Morales, E; Pastor, L; Sancho, J V; Sánchez-Ramírez, J E; Hernández, F

    2016-01-01

    In this work, two analytical methodologies based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) were developed for quantification of emerging pollutants identified in sewage sludge after a previous wide-scope screening. The target list included 13 emerging contaminants (EC): thiabendazole, acesulfame, fenofibric acid, valsartan, irbesartan, salicylic acid, diclofenac, carbamazepine, 4-aminoantipyrine (4-AA), 4-acetyl aminoantipyrine (4-AAA), 4-formyl aminoantipyrine (4-FAA), venlafaxine and benzoylecgonine. The aqueous and solid phases of the sewage sludge were analyzed making use of Solid-Phase Extraction (SPE) and UltraSonic Extraction (USE) for sample treatment, respectively. The methods were validated at three concentration levels: 0.2, 2 and 20 μg L(-1) for the aqueous phase, and 50, 500 and 2000 μg kg(-1) for the solid phase of the sludge. In general, the method was satisfactorily validated, showing good recoveries (70-120%) and precision (RSD metabolites of dipyrone had not been studied before in sewage sludge.

  15. Development and validation of LC-MS/MS assay for the determination of Butoconazole in human plasma: Evaluation of systemic absorption following topical application in healthy volunteers

    Directory of Open Access Journals (Sweden)

    Eman G. Nouman

    2017-12-01

    Full Text Available Butoconazole is an imidazole antifungal that is more effective than miconazole and clotrimazole for treatment of vaginal candidiasis. A highly sensitive tandem mass spectrometric assay was developed and validated to evaluate systemic absorption of Butoconazole following intravaginal administration. Chromatographic separation was achieved using Waters Xterra C18 column (3 µm, 3.0 × 50.0 mm. Liquid-liquid extraction using tert-butyl methyl ether was used for preparation of plasma samples. The mobile phase was solvent A: 0.1% formic acid in water and solvent B: acetonitrile: methanol (30:70, v/v, using gradient elution mode at 0.5 mL/min. Detection at positive electrospray ionization in the MRM mode was then employed. Analysis was carried out within 5.5 min over a linear concentration range of 0.10–30.00 ng/mL. Validation was carried out according to US FDA guidelines for bioanalytical method validation. Matrix effect, recovery efficiency and process efficiency have been investigated for the analyte and internal standard in neat solvent, post-extraction matrix and plasma. The mean percentage recoveries were higher than 80%, the accuracy was 93.51–106.85% and the RSD was below 10% throughout the studied concentration range. Results indicated sufficient stability of the target analyte in plasma at the employed experimental conditions. Results of incurred sample re-analysis and incurred sample stability revealed less than 5% variability. The applicability of the assay for monitoring of the systemic absorption of Butoconazole following intra vaginal application to healthy volunteers was demonstrated. Results confirmed that Butoconazole was detected shortly after intra vaginal administration with Cmax and tmax of 30 ng/mL and 6 h, respectively. Keywords: Butoconazole, LC-MS/MS, Matrix effect, Process efficiency, Recovery efficiency

  16. Development and validation of a self-efficacy scale for postoperative rehabilitation management of lung cancer patients.

    Science.gov (United States)

    Huang, Fei-Fei; Yang, Qing; Han, Xuan Ye; Zhang, Jing-Ping; Lin, Ting

    2017-08-01

    The purpose of this study was to develop a Self-Efficacy Scale for Rehabilitation Management designed specifically for postoperative lung cancer patients (SESPRM-LC) and to evaluate its psychometric properties. Based on the concept of self-management of chronic disease, items were developed from literature review and semistructured interviews of 10 lung cancer patients and screened by expert consultation and pilot testing. Psychometric evaluation was done with 448 postoperative lung cancer patients recruited from 5 tertiary hospitals in Fuzhou, China, by incorporating classical test theory and item response theory methods. A 6-factor structure was illustrated by exploratory factor analysis and confirmed by confirmatory factor analysis, explaining 60.753% of the total variance. The SESPRM-LC achieved Cronbach's α of 0.694 to 0.893, 2-week test-retest reliability of 0.652 to 0.893, and marginal reliability of 0.565 to 0.934. The predictive and criterion validities were demonstrated by significant association with theoretically supported quality-of-life variables (r = 0.211-0.392, P theory analysis showed that the SESPRM-LC offers information about a broad range of self-efficacy measures and discriminates well between patients with high and low levels of self-efficacy. We demonstrated initial support for the reliability and validity of the 27-item SESPRM-LC, as a developmentally appropriate instrument for assessing self-efficacy among lung cancer patients during postoperative rehabilitation. Copyright © 2016 John Wiley & Sons, Ltd.

  17. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  18. Quantitative method for the determination of Iso-fludelone (KOS-1803) in human plasma by LC-MS/MS

    Science.gov (United States)

    Christner, Susan M.; Parise, Robert A.; Levine, Erica D.; Rizvi, Naiyer A.; Gounder, Mrinal M.; Beumer, Jan H.

    2014-01-01

    Epothilones are relatively new tubulin-poison anticancer drugs. Iso-fludelone (KOS-1803) is a synthetic third generation epothilone drug discovered at Memorial Sloan Kettering Cancer Center, and currently in Phase I clinical trials. We report an LC-MS/MS assay for the sensitive, accurate and precise quantitation of Iso-fludelone in 0.2 mL of human plasma. Validation was performed according to FDA guidance. The assay comprised of KOS-1724 as the internal standard and an MTBE liquid-liquid extraction with a water wash step. Separation was achieved with an YMC-Pack ODS-AQ column and an isocratic mobile phase of 0.1% formic acid in acetonitrile and water (70:30, v/v) at 0.3 mL/min for 4 min. Chromatographic separation was followed by electrospray, positive-mode ionization tandem mass spectrometric detection in the multiple reaction monitoring (MRM) mode. The assay was linear from 0.1– 300 ng/mL and was accurate (−9.41–7.07%) and precise (1.03–13.7%) which fulfilled FDA criteria for validation. Recovery from plasma was 73.9–79.7% and ion suppression was negligible (−22.8 to −31.3%). Plasma freeze thaw stability (99.97–105.7%), stability for 11 months at −80 °C (94.93–107.9%), and stability for 6 h at room temperature (94.75–105.5%) were all acceptable. This assay is currently being applied to quantitate Iso-fludelone in clinical samples. PMID:25168219

  19. Quantitative method for the determination of iso-fludelone (KOS-1803) in human plasma by LC-MS/MS.

    Science.gov (United States)

    Christner, Susan M; Parise, Robert A; Levine, Erica D; Rizvi, Naiyer A; Gounder, Mrinal M; Beumer, Jan H

    2014-11-01

    Epothilones are relatively new tubulin-poison anticancer drugs. Iso-fludelone (KOS-1803) is a synthetic third generation epothilone drug discovered at Memorial Sloan Kettering Cancer Center, and currently in phase I clinical trials. We report an LC-MS/MS assay for the sensitive, accurate and precise quantitation of iso-fludelone in 0.2mL of human plasma. Validation was performed according to FDA guidance. The assay comprised of KOS-1724 as the internal standard and an MTBE liquid-liquid extraction with a water wash step. Separation was achieved with an YMC-Pack ODS-AQ column and an isocratic mobile phase of 0.1% formic acid in acetonitrile and water (70:30, v/v) at 0.3mL/min for 4min. Chromatographic separation was followed by electrospray, positive-mode ionization tandem mass spectrometric detection in the multiple reaction monitoring (MRM) mode. The assay was linear from 0.1 to 300ng/mL and was accurate (-9.41 to -7.07%) and precise (1.03-13.7%) which fulfilled FDA criteria for validation. Recovery from plasma was 73.9-79.7% and ion suppression was negligible (-22.8 to -31.3%). Plasma freeze-thaw stability (99.97-105.7%), stability for 11 months at -80°C (94.93-107.9%), and stability for 6h at room temperature (94.75-105.5%) were all acceptable. This assay is currently being applied to quantitate iso-fludelone in clinical samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Application of survival analysis methodology to the quantitative analysis of LC-MS proteomics data

    KAUST Repository

    Tekwe, C. D.

    2012-05-24

    MOTIVATION: Protein abundance in quantitative proteomics is often based on observed spectral features derived from liquid chromatography mass spectrometry (LC-MS) or LC-MS/MS experiments. Peak intensities are largely non-normal in distribution. Furthermore, LC-MS-based proteomics data frequently have large proportions of missing peak intensities due to censoring mechanisms on low-abundance spectral features. Recognizing that the observed peak intensities detected with the LC-MS method are all positive, skewed and often left-censored, we propose using survival methodology to carry out differential expression analysis of proteins. Various standard statistical techniques including non-parametric tests such as the Kolmogorov-Smirnov and Wilcoxon-Mann-Whitney rank sum tests, and the parametric survival model and accelerated failure time-model with log-normal, log-logistic and Weibull distributions were used to detect any differentially expressed proteins. The statistical operating characteristics of each method are explored using both real and simulated datasets. RESULTS: Survival methods generally have greater statistical power than standard differential expression methods when the proportion of missing protein level data is 5% or more. In particular, the AFT models we consider consistently achieve greater statistical power than standard testing procedures, with the discrepancy widening with increasing missingness in the proportions. AVAILABILITY: The testing procedures discussed in this article can all be performed using readily available software such as R. The R codes are provided as supplemental materials. CONTACT: ctekwe@stat.tamu.edu.

  1. On-line LC-GC and comprehensive two-dimensional LCxGC-ToF MS for the analysis of complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, Hans-Gerd [Central Analytical Science, Unilever Research and Development, P.O. Box 114, 3130 AC, Vlaardingen (Netherlands); Koning, Sjaak de [Separation Science Group, LECO Instrumente GmbH, Marie-Bernays-Ring 31, 41199, Moenchengladbach (Germany); Brinkman, Udo A.Th. [Department of Analytical Chemistry and Applied Spectroscopy, Free University, De Boelelaan 1083, 1081 HV, Amsterdam (Netherlands)

    2004-04-01

    LC x GC is a logical extension of LC-GC. Unlike LC-GC, which only allows detailed analysis of one group of analytes from a complex sample, LC x GC enables detailed mapping of the entire sample. Due to the high degree of orthogonality and the complementary nature of the two dimensions, the method has a very high resolving power. Comprehensive LC x GC chromatograms often show ordered structures which allow group-wise integration as well as detailed target compound analysis. Hyphenation with mass spectrometry is straightforward, which further widens the application range of the technique. (orig.)

  2. Determination of toxins involved in ciguatera fish poisoning in the Pacific by LC/MS.

    Science.gov (United States)

    Yogi, Kentaro; Sakugawa, Satsuki; Oshiro, Naomasa; Ikehara, Tsuyoshi; Sugiyama, Kiminori; Yasumoto, Takeshi

    2014-01-01

    Ciguatera fish poisoning is the most extensive and difficult to control of the seafood poisonings. To facilitate monitoring of fish toxicity, toxin profiles were investigated by an LC/MS/MS method using 14 reference toxins on eight representative species of fish collected in four different areas of the Pacific. Snappers and groupers from Okinawa contained ciguatoxin-1B (CTX1B) and two deoxy congeners at variable but species-specific ratios, while red snapper, Lutjanus bohar, from Minamitorishima, and amberjack, Seriola dumerili, from Hawaii, contained both CTX1B-type and CTX3C-type toxins. Spotted knifejaw, Oplegnathus punctatus, from Okinawan waters, contained mainly CTX4A and CTX4B, but the same species caught at Miyazaki was contaminated primarily with the CTX3C-type toxins. Otherwise, the toxin profiles were consistently species-specific in fish collected from various locations around Okinawa over 20 years. The LC/MS/MS and mouse bioassay results agreed well, indicating the LC/MS/MS method is a promising alternative to the mouse bioassay. Pure CTX1B and CTX3C were prepared for use in future LC/MS/MS analysis.

  3. Analysis of cocaine/crack biomarkers in meconium by LC-MS.

    Science.gov (United States)

    D'Avila, Felipe Bianchini; Ferreira, Pâmela C Lukasewicz; Salazar, Fernanda Rodrigues; Pereira, Andrea Garcia; Santos, Maíra Kerpel Dos; Pechansky, Flavio; Limberger, Renata Pereira; Fröehlich, Pedro Eduardo

    2016-02-15

    Fetal exposure to illicit drugs is a worldwide problem, since many addicted women do not stop using it during pregnancy. Cocaine consumed in powdered (snorted or injected) or smoked (crack cocaine) form are harmful for the baby and its side effects are not completely known. Meconium, the first stool of a newborn, is a precious matrix usually discarded, that may contain amounts of substances consumed in the last two trimesters of pregnancy. Analyzing this biological matrix it is possible to detect the unaltered molecule of cocaine (COC) or its metabolite benzoylecgonine (BZE) and pyrolytic products anhydroecgonine methyl ester (AEME) and anhydroecgonine (AEC). A liquid chromatography mass spectrometry (LC-MS) method was validated for meconium samples after solvent extraction, followed by direct injection of 10μL. Linearity covered a concentration range of 15 to 500ng/mg with a lower limit of quantification (LLOQ) of 15ng/mg for all analytes. Matrix effect was evaluated and showed adequate results. Detection of illicit substances usage can be crucial for the baby, since knowing that can help provide medical care as fast as possible. The method proved to be simple and fast, and was applied to 17 real meconium samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Reported prevalence and quantitative LC-MS methods for the analysis of veterinary drug residues in honey: a review.

    Science.gov (United States)

    Venable, Ryan; Haynes, Carion; Cook, Jo Marie

    2014-04-01

    Insect pollination increases the value and productivity of three-quarters of crop species grown for food. Declining beehive health in commercial apiaries has resulted in numerous reports from government laboratories worldwide of contamination with antimicrobial chemicals in honey. This review includes pertinent discussion of legislation and events leading to increased government oversight in the commercial honey market. A detailed summary of the variety and prevalence of veterinary drug residues being found in honey as well as a selection of robust quantitative and confirmatory LC-MS methods with an emphasis on those adopted by government testing laboratories are presented.

  5. Method and platform standardization in MRM-based quantitative plasma proteomics.

    Science.gov (United States)

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This

  6. Development of a SIDA-LC-MS/MS Method for the Determination of Phomopsin A in Legumes.

    Science.gov (United States)

    Schloß, Svenja; Koch, Matthias; Rohn, Sascha; Maul, Ronald

    2015-12-09

    A novel method for the determination of phomopsin A (1) in lupin flour, pea flour, and bean flour as well as whole lupin plants was established based on stable isotope dilution assay (SIDA) LC-MS/MS using (15)N6-1 as an isotopically labeled internal standard. Artificially infected samples were used to develop an optimized extraction procedure and sample pretreatment. The limits of detection were 0.5-1 μg/kg for all matrices. The limits of quantitation were 2-4 μg/kg. The method was used to analyze flour samples generated from selected legume seeds and lupin plant samples that had been inoculated with Diaporthe toxica and two further fungal strains. Finally, growing lupin plants infected with D. toxica were investigated to simulate a naturally in-field mycotoxicosis. Toxin levels of up to 10.1 μg/kg of 1 were found in the pods and 7.2 μg/kg in the stems and leaves.

  7. Screening of 23 β-lactams in foodstuffs by LC-MS/MS using an alkaline QuEChERS-like extraction.

    Science.gov (United States)

    Bessaire, Thomas; Mujahid, Claudia; Beck, Andrea; Tarres, Adrienne; Savoy, Marie-Claude; Woo, Pei-Mun; Mottier, Pascal; Desmarchelier, Aurélien

    2018-04-01

    A fast and robust high performance LC-MS/MS screening method was developed for the analysis of β-lactam antibiotics in foods of animal origin: eggs, raw milk, processed dairy ingredients, infant formula, and meat- and fish-based products including baby foods. QuEChERS extraction with some adaptations enabled 23 drugs to be simultaneously monitored. Screening target concentrations were set at levels adequate to ensure compliance with current European, Chinese, US and Canadian regulations. The method was fully validated according to the European Community Reference Laboratories Residues Guidelines using 93 food samples of different composition. False-negative and false-positive rates were below 5% for all analytes. The method is adequate for use in high-routine laboratories. A 1-year study was additionally conducted to assess the stability of the 23 analytes in the working standard solution.

  8. A sustainable on-line CapLC method for quantifying antifouling agents like irgarol-1051 and diuron in water samples: Estimation of the carbon footprint.

    Science.gov (United States)

    Pla-Tolós, J; Serra-Mora, P; Hakobyan, L; Molins-Legua, C; Moliner-Martinez, Y; Campins-Falcó, P

    2016-11-01

    In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-10μg/L for irgarol-1051 and 0.7-10μg/L for diuron. The LODs were 0.015μg/L and 0.2μg/L for irgarol-1051 and diuron, respectively. Precision was also satisfactory (relative standard deviation, RSDcarbon footprint values for the proposed procedure consolidate the operational efficiency (analytical and environmental performance) of in-tube SPME-CapLC-DAD, in general, and in particular for determining irgarol-1051 and diuron in water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  10. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    Science.gov (United States)

    Hurtaud-Pessel, D; Jagadeshwar-Reddy, T; Verdon, E

    2011-10-01

    A liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for screening meat for a wide range of antibiotics used in veterinary medicine. Full-scan mode under high resolution mass spectral conditions using an LTQ-Orbitrap mass spectrometer with resolving power 60,000 full width at half maximum (FWHM) was applied for analysis of the samples. Samples were prepared using two extraction protocols prior to LC-HRMS analysis. The scope of the method focuses on screening the following main families of antibacterial veterinary drugs: penicillins, cephalosporins, sulfonamides, macrolides, tetracyclines, aminoglucosides and quinolones. Compounds were successfully identified in spiked samples from their accurate mass and LC retention times from the acquired full-scan chromatogram. Automated data processing using ToxId software allowed rapid treatment of the data. Analyses of muscle tissues from real samples collected from antibiotic-treated animals was carried out using the above methodology and antibiotic residues were identified unambiguously. Further analysis of the data for real samples allowed the identification of the targeted antibiotic residues but also non-targeted compounds, such as some of their metabolites.

  11. Simultaneous determination of LSD and 2-oxo-3-hydroxy LSD in hair and urine by LC-MS/MS and its application to forensic cases.

    Science.gov (United States)

    Jang, Moonhee; Kim, Jihyun; Han, Inhoi; Yang, Wonkyung

    2015-11-10

    Lysergic acid diethylamide (LSD) is administered in low dosages, which makes its detection in biological matrices a major challenge in forensic toxicology. In this study, two sensitive and reliable methods based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) were established and validated for the simultaneous determination of LSD and its metabolite, 2-oxo-3-hydroxy-LSD (O-H-LSD), in hair and urine. Target analytes in hair were extracted using methanol at 38°C for 15h and analyzed by LC-MS/MS. For urine sample preparation, liquid-liquid extraction was performed. Limits of detection (LODs) in hair were 0.25pg/mg for LSD and 0.5pg/mg for O-H-LSD. In urine, LODs were 0.01 and 0.025ng/ml for LSD and O-H-LSD, respectively. Method validation results showed good linearity and acceptable precision and accuracy. The developed methods were applied to authentic specimens from two legal cases of LSD ingestion, and allowed identification and quantification of LSD and O-H-LSD in the specimens. In the two cases, LSD concentrations in hair were 1.27 and 0.95pg/mg; O-H-LSD was detected in one case, but its concentration was below the limit of quantification. In urine samples collected from the two suspects 8 and 3h after ingestion, LSD concentrations were 0.48 and 2.70ng/ml, respectively, while O-H-LSD concentrations were 4.19 and 25.2ng/ml, respectively. These methods can be used for documenting LSD intake in clinical and forensic settings. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Toward a Unified Validation Framework in Mixed Methods Research

    Science.gov (United States)

    Dellinger, Amy B.; Leech, Nancy L.

    2007-01-01

    The primary purpose of this article is to further discussions of validity in mixed methods research by introducing a validation framework to guide thinking about validity in this area. To justify the use of this framework, the authors discuss traditional terminology and validity criteria for quantitative and qualitative research, as well as…

  13. Laser cooling and optical detection of excitations in a LC electrical circuit

    DEFF Research Database (Denmark)

    Taylor, J. M.; Sørensen, Anders Søndberg; Marcus, Charles Masamed

    2011-01-01

    We explore a method for laser cooling and optical detection of excitations in a room temperature LC electrical circuit. Our approach uses a nanomechanical oscillator as a transducer between optical and electronic excitations. An experimentally feasible system with the oscillator capacitively...... coupled to the LC and at the same time interacting with light via an optomechanical force is shown to provide strong electromechanical coupling. Conditions for improved sensitivity and quantum limited readout of electrical signals with such an “optical loud speaker” are outlined....

  14. Ex vivo investigation of ocular tissue distribution following intravitreal administration of connexin43 mimetic peptide using the microdialysis technique and LC-MS/MS.

    Science.gov (United States)

    Bisht, Rohit; Mandal, Abhirup; Rupenthal, Ilva D; Mitra, Ashim K

    2016-12-01

    This study aimed to develop and evaluate an ex vivo eye model for intravitreal drug sampling and tissue distribution of connexin43 mimetic peptide (Cx43MP) following intravitreal injection using the microdialysis technique and LC-MS/MS. An LC-MS/MS method was developed, validated, and applied for quantification of Cx43MP in ocular tissues. Microdialysis probes were calibrated for in vitro recovery studies. Bovine eyes were fixed in a customized eye holder and after intravitreal injection of Cx43MP, microdialysis probes were implanted in the vitreous body. Vitreous samples were collected at particular time intervals over 24 h. Moreover, 24 and 48 h after intravitreal injection ocular tissues were collected, processed, and analyzed for Cx43MP concentrations using LC-MS/MS. The LC-MS/MS method showed good linearity (r 2  = 0.9991). The mean percent recovery for lower (LQC), medium (MQC), and higher quality control (HQC) (0.244, 3.906, and 125 μg/mL) was found to be 83.83, 84.92, and 94.52, respectively, with accuracy ranges between 96 and 99 % and limits of detection (LOD) and quantification (LOQ) of 0.122 and 0.412 μg/mL. The in vitro recovery of the probes was found to be over 80 %. As per microdialysis sample analysis, the Cx43MP concentration was found to increase slowly in the vitreous body up to 16 h and thereafter declined. After 48 h, the Cx43MP concentration was higher in vitreous, cornea, and retina compared to lens, iris, and aqueous humor. This ex vivo model may therefore be a useful tool to investigate intravitreal kinetics and ocular disposition of therapeutic molecules after intravitreal injection.

  15. Analytical models approximating individual processes: a validation method.

    Science.gov (United States)

    Favier, C; Degallier, N; Menkès, C E

    2010-12-01

    Upscaling population models from fine to coarse resolutions, in space, time and/or level of description, allows the derivation of fast and tractable models based on a thorough knowledge of individual processes. The validity of such approximations is generally tested only on a limited range of parameter sets. A more general validation test, over a range of parameters, is proposed; this would estimate the error induced by the approximation, using the original model's stochastic variability as a reference. This method is illustrated by three examples taken from the field of epidemics transmitted by vectors that bite in a temporally cyclical pattern, that illustrate the use of the method: to estimate if an approximation over- or under-fits the original model; to invalidate an approximation; to rank possible approximations for their qualities. As a result, the application of the validation method to this field emphasizes the need to account for the vectors' biology in epidemic prediction models and to validate these against finer scale models. Copyright © 2010 Elsevier Inc. All rights reserved.

  16. A novel study of screening and confirmation of modafinil, adrafinil and their metabolite modafinilic acid under EI-GC-MS and ESI-LC-MS-MS ionization.

    Science.gov (United States)

    Dubey, S; Ahi, S; Reddy, I M; Kaur, T; Beotra, A; Jain, S

    2009-12-01

    Adrafinil and modafinil have received wide publicity and have become controversial in the sporting world when several athletes were discovered allegedly using these drugs as doping agents. By acknowledging the facts, the World Anti-Doping Agency (WADA) banned these drugs in sports since 2004. The present study explores the possibility of differentiating adrafinil and modafinil and their major metabolites under electron impact ionization in gas chromatograph-mass spectrometer (GC-MSD) and electrospray ionization in liquid chromatograph-mass spectrometer (LC-MS/MS) by studying the fragmentation pattern of these drugs. Adrafinil, modafinil and their major metabolite, modafinilic acid were analyzed on EI-GC-MSD and ESI-LC-MS/MS using various individual parameters on both the instruments. The analytical technique and equipment used in the analysis were an Agilent 6890N GC with 5973 mass selective detector for the GC-MSD analysis and an Agilent 1100 HPLC with API-3200 Triple quadrupole mass spectrometer for the LC-MS/MS analysis. Validation of both methods was performed using six replicates at different concentrations. The results show that adrafinil, modafinil and their major metabolite modafinilic acid could be detected as a single artifact without differentiation under EI-GC-MSD analysis. However, all drugs could be detected and differentiated under ESI-LCMS/MS analysis without any artifaction. The GC-MSD analysis gives a single artifact for both the drugs without differentiation and thus can be used as a marker for screening purposes. Further, the Multiple Reaction Monitoring (MRM) method developed under LC-MS/MS is fit for the purpose for confirmation of suspicious samples in routine sports testing and in forensic and clinical analysis.

  17. Induction heating of liquids with an L-LC resonant tank

    OpenAIRE

    Quirós Jacobo, Francisco Javier; Martín Segura, Guillermo; Heredero Peris, Daniel; Montesinos Miracle, Daniel

    2013-01-01

    Induction heating (IH) systems are used in many applications because they present many advantages compared other heating methods like quicker heating or faster start-up. This paper studies the application of IH systems for liquid heating using an L-LC resonant tank.

  18. APPLICATION OF LIQUID-CHROMATOGRAPHY COMBINED WITH MASS-SPECTROMETRY (LC-MS) TO ESTABLISH IDENTITY AND PURITY OF PET-RADIOPHARMACEUTICALS

    NARCIS (Netherlands)

    FRANSSEN, EJF; LUURTSEMA, G; MEDEMA, J; VISSER, GM; JERONISMUSSHALINGH, CM; BRUINS, AP; VAALBURG, W

    This article describes the application of liquid chromatography combined with mass-spectrometry (LC-MS) as a new quality control tool for PET-radiopharmaceuticals. The final step in the production of 2-[F-18]fluoro-2-deoxy-D-glucose (F-18-FDG) is a purification by HPLC. This procedure was validated

  19. Short Communication: Testosterone Measured with an Automatic Immunoassay Compares Reasonbly Well to Results Obtained by LC-MS/MS

    DEFF Research Database (Denmark)

    Knudsen, Cindy Søndersø; Højskov, Carsten Schriver; Møller, Holger Jon

    2016-01-01

    Background: Previous studies have reported problems measuring testosterone with immunological assays. Here we explore an automatic second generation immunoassay compared to a LC-MS/MS method. Methods: We collected blood samples from 76 women and measured testosterone, progesterone, gender...... hormonebinding globulin (SHBG), and albumin employing Cobas e601/c501. Testosterone, androstenedione (andro), dehydroepiandrosterone sulphate (DHEAS), and 17-hydroxyprogesterone (17-OHP) concentrations were measured employing LC-MS/MS. We evaluated the difference between testosterone measured by the two methods...... and examined the potential interference from the selected steroids and bindings proteins. Results: Testosterone concentrations measured by the two methods yielded: Cobas e601 = 1.240 x (LC-MS/MS) - 0.197, r = 0.84, for testosterone concentrations between 0.22 - 4.9 nmol/L. A positive correlation was observed...

  20. Solution structure of LC4 transmembrane segment of CCR5.

    Directory of Open Access Journals (Sweden)

    Kazuhide Miyamoto

    Full Text Available CC-chemokine receptor 5 (CCR5 is a specific co-receptor allowing the entry of human immunodeficiency virus type 1 (HIV-1. The LC4 region in CCR5 is required for HIV-1 entry into the cells. In this study, the solution structure of LC4 in SDS micelles was elucidated by using standard 1H two-dimensional NMR spectroscopy, circular dichroism, and fluorescence quenching. The LC4 structure adopts two helical structures, whereas the C-terminal part remains unstructured. The positions in which LC4 binds to the HIV-1 inhibitory peptide LC5 were determined by docking calculations in addition to NMR data. The poses showed the importance of the hydrophobic interface of the assembled structures. The solution structure of LC4 elucidated in the present work provides a structural basis for further studies on the HIV-1 inhibitory function of the LC4 region.

  1. Solution structure of LC4 transmembrane segment of CCR5.

    Science.gov (United States)

    Miyamoto, Kazuhide; Togiya, Kayo

    2011-01-01

    CC-chemokine receptor 5 (CCR5) is a specific co-receptor allowing the entry of human immunodeficiency virus type 1 (HIV-1). The LC4 region in CCR5 is required for HIV-1 entry into the cells. In this study, the solution structure of LC4 in SDS micelles was elucidated by using standard 1H two-dimensional NMR spectroscopy, circular dichroism, and fluorescence quenching. The LC4 structure adopts two helical structures, whereas the C-terminal part remains unstructured. The positions in which LC4 binds to the HIV-1 inhibitory peptide LC5 were determined by docking calculations in addition to NMR data. The poses showed the importance of the hydrophobic interface of the assembled structures. The solution structure of LC4 elucidated in the present work provides a structural basis for further studies on the HIV-1 inhibitory function of the LC4 region.

  2. Improved Stable Isotope Dilution Assay for Dietary Folates Using LC-MS/MS and Its Application to Strawberries

    Directory of Open Access Journals (Sweden)

    Lisa Striegel

    2018-02-01

    Full Text Available Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate, and 5-formyltetrahydrofolate were quantified using 13C-labeled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection, and limit of quantification and revealed to be a precise, sensitive, and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany and Australia were investigated. Total folates varied from 59 to 153 μg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16% of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates.

  3. Improved stable isotope dilution assay for dietary folates using LC-MS/MS and its application to strawberries

    Science.gov (United States)

    Striegel, Lisa; Chebib, Soraya; Netzel, Michael E.; Rychlik, Michael

    2018-02-01

    Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate and 5-formyltetrahydrofolate were quantified using 13C-labelled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection and limit of quantification and revealed to be a precise, sensitive and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany were investigated. Total folates varied from 59 to 153 µg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16 % of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates.

  4. Silver ion chromatography for peak resolution enhancement: Application to the preparative separation of two sesquiterpenes using online heart-cutting LC-LC technique.

    Science.gov (United States)

    Yang, Yang; Zhang, Yongmin; Wei, Chong; Li, Jing; Sun, Wenji

    2018-09-01

    Silver ion chromatography, utilizing columns packed with silver ions bonded to silica gel, has proved to be an invaluable technique for the analysis of some positional isomers. In this work, silver ion chromatography by combination with online heart-cutting LC-LC technique for the preparative separation of two sesquiterpenes positional isomers from a natural product was investigated. On the basis of the evaluation that silver ion content impacts on the separation, the laboratory-made silver ion columns, utilizing silica gel impregnated with 15% silver nitrate as column packing materials, were used for peak resolution improvement of these two isomers and the preparative separation of them in heart-cutting LC-LC. The relationship among the maximal sample load, flow rate and peak resolution in the silver ion column were optimized, and the performance of the silver ion column was compared with conventional C 18 column and silica gel column. Based on the developed chromatographic conditions, online heart-cutting LC-LC chromatographic separation system in combination with a silica gel column and a silver ion column that was applied to preparative separation of these two isomers from a traditional Chinese medicine, Inula racemosa Hook.f., was established. The results showed that the online heart-cutting LC-LC technique by combination of a silica gel column and a silver ion column for the preparative separation of these two positional isomers from this natural plant was superior to the preparative separation performed on a single-column system with C 18 column or silica gel column. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Prescription and illicit psychoactive drugs in oral fluid--LC-MS/MS method development and analysis of samples from Brazilian drivers.

    Science.gov (United States)

    Zancanaro, Ivomar; Limberger, Renata Pereira; Bohel, Paula O; dos Santos, Maíra Kerpel; De Boni, Raquel B; Pechansky, Flavio; Caldas, Eloisa Dutra

    2012-11-30

    This study is part of a larger project designed to investigate the prevalence of psychoactive drug (PAD) use among Brazilian drivers. In this paper we describe the development and validation of an analytical method to analyze 32 prescription and illicit PADs (amphetamines, benzodiazepines, cocaine, cannabis, opioids, ketamine and m-CPP) and metabolites in oral fluid samples collected with a Quantisal™ device. Samples were extracted with ethyl acetate:hexane and analyzed by LC-MS/MS. Instrumental LOD ranged from 0.26 to 0.65 ng/mL. Mean procedural recoveries at 1.3 ng/mL (LLOQ) ranged from 50% to 120% for 24 compounds. Recoveries were concentration independent, with the exception of femproporex, heroin and ecgonine methyl-ester (EME) for which the recovery decreased significantly at higher levels (13 and 52 ng/mL). RSD was drugs, cocaine/metabolites were the analytes most detected in the samples (129; 5.8%), followed by amphetamines/metabolite (69; 3.1%), benzodiazepines (28; 1.2%), cannabinoids (23; 1.1%) and opioids (8; 0.4%). Detection of at least two PADs from different classes accounted for 9.3% of the 236 positive samples. Cocaine was found at higher levels in the samples (up to 1165 ng/mL). Preventive measures aimed at reducing the use of PADs by drivers in Brazil will certainly contribute to decrease the country's highway death rates. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Model-Based Method for Sensor Validation

    Science.gov (United States)

    Vatan, Farrokh

    2012-01-01

    Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in situ platforms. One of NASA s key mission requirements is robust state estimation. Sensing, using a wide range of sensors and sensor fusion approaches, plays a central role in robust state estimation, and there is a need to diagnose sensor failure as well as component failure. Sensor validation can be considered to be part of the larger effort of improving reliability and safety. The standard methods for solving the sensor validation problem are based on probabilistic analysis of the system, from which the method based on Bayesian networks is most popular. Therefore, these methods can only predict the most probable faulty sensors, which are subject to the initial probabilities defined for the failures. The method developed in this work is based on a model-based approach and provides the faulty sensors (if any), which can be logically inferred from the model of the system and the sensor readings (observations). The method is also more suitable for the systems when it is hard, or even impossible, to find the probability functions of the system. The method starts by a new mathematical description of the problem and develops a very efficient and systematic algorithm for its solution. The method builds on the concepts of analytical redundant relations (ARRs).

  7. Validated modified Lycopodium spore method development for ...

    African Journals Online (AJOL)

    Validated modified lycopodium spore method has been developed for simple and rapid quantification of herbal powdered drugs. Lycopodium spore method was performed on ingredients of Shatavaryadi churna, an ayurvedic formulation used as immunomodulator, galactagogue, aphrodisiac and rejuvenator. Estimation of ...

  8. Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.

    Science.gov (United States)

    Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J

    2015-02-01

    In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.

  9. Screening for anabolic steroids in urine of forensic cases using fully automated solid phase extraction and LC-MS-MS.

    Science.gov (United States)

    Andersen, David W; Linnet, Kristian

    2014-01-01

    A screening method for 18 frequently measured exogenous anabolic steroids and the testosterone/epitestosterone (T/E) ratio in forensic cases has been developed and validated. The method involves a fully automated sample preparation including enzyme treatment, addition of internal standards and solid phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using electrospray ionization with adduct formation for two compounds. Urine samples from 580 forensic cases were analyzed to determine the T/E ratio and occurrence of exogenous anabolic steroids. Extraction recoveries ranged from 77 to 95%, matrix effects from 48 to 78%, overall process efficiencies from 40 to 54% and the lower limit of identification ranged from 2 to 40 ng/mL. In the 580 urine samples analyzed from routine forensic cases, 17 (2.9%) were found positive for one or more anabolic steroids. Only seven different steroids including testosterone were found in the material, suggesting that only a small number of common steroids are likely to occur in a forensic context. The steroids were often in high concentrations (>100 ng/mL), and a combination of steroids and/or other drugs of abuse were seen in the majority of cases. The method presented serves as a fast and automated screening procedure, proving the suitability of LC-MS-MS for analyzing anabolic steroids. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. A novel screening method for 64 new psychoactive substances and 5 amphetamines in blood by LC-MS/MS and application to real cases.

    Science.gov (United States)

    Vaiano, Fabio; Busardò, Francesco P; Palumbo, Diego; Kyriakou, Chrystalla; Fioravanti, Alessia; Catalani, Valeria; Mari, Francesco; Bertol, Elisabetta

    2016-09-10

    Identification and quantification of new psychoactive substances (NPS), both in biological and non-biological samples, represent a hard challenge for forensic toxicologists. NPS are increasingly emerging on illegal drug market. Many cases of co-consumption of NPS and other substances have also been reported. Hence, the development of analytical methods aiming at the detection of a broad-spectrum of compounds (NPS and "traditional" drugs) could be helpful. In this paper, a fully validated screening method in blood for the simultaneous detection of 69 substances, including 64 NPS (28 synthetic cannabinoids, 19 synthetic cathinones, 5 phenethylamines, 3 indanes, 2 piperazines, 2 tryptamines, 2 phencyclidine, methoxetamine, ketamine and its metabolite) and 5 amphetamines (amphetamine, methamphetamine, MDMA, MDA, 3,4-methylenedioxy-N-ethylamphetamine - MDEA-) by a dynamic multiple reaction monitoring analysis through liquid chromatography - tandem mass spectrometry (LC-MS/MS) is described. This method is very fast, easy to perform and cheap as it only requires the deproteinization of 200μL of blood sample with acetonitrile. The chromatographic separation is achieved with a C18 column. The analysis is very sensitive, with limits of quantification ranging from 0.1 to 0.5ng/mL. The method is linear from 1 to 100ng/mL and the coefficient of determination (R(2)) was always above 0.9900. Precision and accuracy were acceptable at any quality control level and recovery efficiency range was 72-110%. Matrix effects did not negatively affect the analytical sensitivity. This method was successfully applied to three real cases, allowing identification and quantification of: mephedrone and methamphetamine (post-mortem); ketamine, MDMA and MDA (post-mortem); AB-FUBINACA (ante-mortem). Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Meenakshi Dahiya

    2010-01-01

    Full Text Available Ivermectin, a veterinary drug, is commonly used endectocide for animal husbandry. The drug is available in the form of subcutaneous or topical formulations. Its application may cause accumulation of its residues into the animal tissues, which ultimately find their way into the food products, such as milk and meat products. In order to determine the residues of ivermectin in milk, a comparatively simple, sensitive and rapid method was developed and validated using LC-MS/MS. The MRM transitions corresponding to m/z 892.71>569.6, 892.71>551.5 and 892.71>307.3 were used for the purpose of quantification and evaluation of other parameters of the method. The limit of detection of the method was found to be 0.1 μg/kg and the limit of quantitation was calculated as 0.2 μg/kg. The method was found to be linear in the range of 1.0 ng/mL to 100.0 ng/mL with correlation coefficient of 0.9992 for pure calibration curve and 0.9990 for the matrix- matched calibration curve. The recoveries of ivermectin from the spiked samples of raw milk were found between 85 to 105%.

  12. LC-MS n Analysis of Isomeric Chondroitin Sulfate Oligosaccharides Using a Chemical Derivatization Strategy

    Science.gov (United States)

    Huang, Rongrong; Pomin, Vitor H.; Sharp, Joshua S.

    2011-09-01

    Improved methods for structural analyses of glycosaminoglycans (GAGs) are required to understand their functional roles in various biological processes. Major challenges in structural characterization of complex GAG oligosaccharides using liquid chromatography-mass spectrometry (LC-MS) include the accurate determination of the patterns of sulfation due to gas-phase losses of the sulfate groups upon collisional activation and inefficient on-line separation of positional sulfation isomers prior to MS/MS analyses. Here, a sequential chemical derivatization procedure including permethylation, desulfation, and acetylation was demonstrated to enable both on-line LC separation of isomeric mixtures of chondroitin sulfate (CS) oligosaccharides and accurate determination of sites of sulfation by MS n . The derivatized oligosaccharides have sulfate groups replaced with acetyl groups, which are sufficiently stable to survive MS n fragmentation and reflect the original sulfation patterns. A standard reversed-phase LC-MS system with a capillary C18 column was used for separation, and MS n experiments using collision-induced dissociation (CID) were performed. Our results indicate that the combination of this derivatization strategy and MS n methodology enables accurate identification of the sulfation isomers of CS hexasaccharides with either saturated or unsaturated nonreducing ends. Moreover, derivatized CS hexasaccharide isomer mixtures become separable by LC-MS method due to different positions of acetyl modifications.

  13. An LC-MS/MS-Based Method for the Quantification of Pyridox(am)ine 5'-Phosphate Oxidase Activity in Dried Blood Spots from Patients with Epilepsy.

    Science.gov (United States)

    Wilson, Matthew P; Footitt, Emma J; Papandreou, Apostolos; Uudelepp, Mari-Liis; Pressler, Ronit; Stevenson, Danielle C; Gabriel, Camila; McSweeney, Mel; Baggot, Matthew; Burke, Derek; Stödberg, Tommy; Riney, Kate; Schiff, Manuel; Heales, Simon J R; Mills, Kevin A; Gissen, Paul; Clayton, Peter T; Mills, Philippa B

    2017-09-05

    We report the development of a rapid, simple, and robust LC-MS/MS-based enzyme assay using dried blood spots (DBS) for the diagnosis of pyridox(am)ine 5'-phosphate oxidase (PNPO) deficiency (OMIM 610090). PNPO deficiency leads to potentially fatal early infantile epileptic encephalopathy, severe developmental delay, and other features of neurological dysfunction. However, upon prompt treatment with high doses of vitamin B 6 , affected patients can have a normal developmental outcome. Prognosis of these patients is therefore reliant upon a rapid diagnosis. PNPO activity was quantified by measuring pyridoxal 5'-phosphate (PLP) concentrations in a DBS before and after a 30 min incubation with pyridoxine 5'-phosphate (PNP). Samples from 18 PNPO deficient patients (1 day-25 years), 13 children with other seizure disorders receiving B 6 supplementation (1 month-16 years), and 37 child hospital controls (5 days-15 years) were analyzed. DBS from the PNPO-deficient samples showed enzyme activity levels lower than all samples from these two other groups as well as seven adult controls; no false positives or negatives were identified. The method was fully validated and is suitable for translation into the clinical diagnostic arena.

  14. Rapid extraction combined with LC-tandem mass spectrometry (CREM-LC/MS/MS) for the determination of ciguatoxins in ciguateric fish flesh.

    Science.gov (United States)

    Lewis, Richard J; Yang, Aijun; Jones, Alun

    2009-07-01

    Ciguatera is a significant food borne disease caused by potent polyether toxins known as ciguatoxins, which accumulate in the flesh of ciguateric fish at risk levels above 0.1 ppb. The management of ciguatera has been hindered by the lack of analytical methods to detect and quantify clinically relevant levels of ciguatoxin in easily prepared crude extracts of fish. Here we report a ciguatoxin rapid extraction method (CREM) that allows the rapid preparation of fish flesh extracts for the detection and quantification of ciguatoxin by gradient reversed-phase liquid chromatography-tandem mass spectrometry (LC/MS/MS). CREM-LC/MS/MS delivers a linear response to P-CTX-1 spiked into fish prior to extraction. A similar response was obtained for P-CTX-1 spiked after extraction, indicating >95% extraction efficiency was achieved overall and 85% at the limit of quantification (0.1 ppb). Using this approach, levels >or=0.1 ppb P-CTX-1 could be detected and quantified from an extract of 2g fish flesh, making it suitable as a confirmatory assay for suspect ciguateric carnivorous fish in the Pacific Ocean. The approach is designed to simplify the extraction and analysis of multiple samples per day.

  15. Cross-Validation of Survival Bump Hunting by Recursive Peeling Methods.

    Science.gov (United States)

    Dazard, Jean-Eudes; Choe, Michael; LeBlanc, Michael; Rao, J Sunil

    2014-08-01

    We introduce a survival/risk bump hunting framework to build a bump hunting model with a possibly censored time-to-event type of response and to validate model estimates. First, we describe the use of adequate survival peeling criteria to build a survival/risk bump hunting model based on recursive peeling methods. Our method called "Patient Recursive Survival Peeling" is a rule-induction method that makes use of specific peeling criteria such as hazard ratio or log-rank statistics. Second, to validate our model estimates and improve survival prediction accuracy, we describe a resampling-based validation technique specifically designed for the joint task of decision rule making by recursive peeling (i.e. decision-box) and survival estimation. This alternative technique, called "combined" cross-validation is done by combining test samples over the cross-validation loops, a design allowing for bump hunting by recursive peeling in a survival setting. We provide empirical results showing the importance of cross-validation and replication.

  16. Identification of Eupatilin from Artemisia argyi as a Selective PPARα Agonist Using Affinity Selection Ultrafiltration LC-MS

    Directory of Open Access Journals (Sweden)

    Yongsoo Choi

    2015-07-01

    Full Text Available Peroxisome proliferator-activated receptors (PPARs are key nuclear receptors and therapeutic targets for the treatment of metabolic diseases through the regulation of insulin resistance, diabetes, and dyslipidemia. Although a few drugs that target PPARs have been approved, more diverse and novel PPAR ligands are necessary to improve the safety and efficacy of available drugs. To expedite the search for new natural agonists of PPARs, we developed a screening assay based on ultrafiltration liquid chromatography-mass spectrometry (LC-MS that is compatible with complex samples such as dietary foods or botanical extracts. The known PPARα and/or PPARγ ligands resveratrol and rosiglitazone were used as positive controls to validate the developed method. When applied to the screening of an Artemisia argyi extract, eupatilin was identified as a selective PPARα ligand. A PPAR competitive binding assay based on FRET detection also confirmed eupatilin as a selective PPARα agonist exhibiting a binding affinity of 1.18 μM (IC50. Furthermore, eupatilin activation of the transcriptional activity of PPARα was confirmed using a cell-based transactivation assay. Thus, ultrafiltration LC-MS is a suitable assay for the identification of PPAR ligands in complex matrixes such as extracts of dietary foods and botanicals.

  17. Contaminant screening of wastewater with HPLC-IM-qTOF-MS and LC+LC-IM-qTOF-MS using a CCS database.

    Science.gov (United States)

    Stephan, Susanne; Hippler, Joerg; Köhler, Timo; Deeb, Ahmad A; Schmidt, Torsten C; Schmitz, Oliver J

    2016-09-01

    Non-target analysis has become an important tool in the field of water analysis since a broad variety of pollutants from different sources are released to the water cycle. For identification of compounds in such complex samples, liquid chromatography coupled to high resolution mass spectrometry are often used. The introduction of ion mobility spectrometry provides an additional separation dimension and allows determining collision cross sections (CCS) of the analytes as a further physicochemical constant supporting the identification. A CCS database with more than 500 standard substances including drug-like compounds and pesticides was used for CCS data base search in this work. A non-target analysis of a wastewater sample was initially performed with high performance liquid chromatography (HPLC) coupled to an ion mobility-quadrupole-time of flight mass spectrometer (IM-qTOF-MS). A database search including exact mass (±5 ppm) and CCS (±1 %) delivered 22 different compounds. Furthermore, the same sample was analyzed with a two-dimensional LC method, called LC+LC, developed in our group for the coupling to IM-qTOF-MS. This four dimensional separation platform revealed 53 different compounds, identified over exact mass and CCS, in the examined wastewater sample. It is demonstrated that the CCS database can also help to distinguish between isobaric structures exemplified for cyclophosphamide and ifosfamide. Graphical Abstract Scheme of sample analysis and database screening.

  18. LC-MS/MS Peptide Mapping with Automated Data Processing for Routine Profiling of N-Glycans in Immunoglobulins

    Science.gov (United States)

    Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi

    2014-06-01

    Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.

  19. Method Validation Procedure in Gamma Spectroscopy Laboratory

    International Nuclear Information System (INIS)

    El Samad, O.; Baydoun, R.

    2008-01-01

    The present work describes the methodology followed for the application of ISO 17025 standards in gamma spectroscopy laboratory at the Lebanese Atomic Energy Commission including the management and technical requirements. A set of documents, written procedures and records were prepared to achieve the management part. The technical requirements, internal method validation was applied through the estimation of trueness, repeatability , minimum detectable activity and combined uncertainty, participation in IAEA proficiency tests assure the external method validation, specially that the gamma spectroscopy lab is a member of ALMERA network (Analytical Laboratories for the Measurements of Environmental Radioactivity). Some of these results are presented in this paper. (author)

  20. Regulation of the autophagy protein LC3 by phosphorylation

    Science.gov (United States)

    Cherra, Salvatore J.; Kulich, Scott M.; Uechi, Guy; Balasubramani, Manimalha; Mountzouris, John; Day, Billy W.

    2010-01-01

    Macroautophagy is a major catabolic pathway that impacts cell survival, differentiation, tumorigenesis, and neurodegeneration. Although bulk degradation sustains carbon sources during starvation, autophagy contributes to shrinkage of differentiated neuronal processes. Identification of autophagy-related genes has spurred rapid advances in understanding the recruitment of microtubule-associated protein 1 light chain 3 (LC3) in autophagy induction, although braking mechanisms remain less understood. Using mass spectrometry, we identified a direct protein kinase A (PKA) phosphorylation site on LC3 that regulates its participation in autophagy. Both metabolic (rapamycin) and pathological (MPP+) inducers of autophagy caused dephosphorylation of endogenous LC3. The pseudophosphorylated LC3 mutant showed reduced recruitment to autophagosomes, whereas the nonphosphorylatable mutant exhibited enhanced puncta formation. Finally, autophagy-dependent neurite shortening induced by expression of a Parkinson disease–associated G2019S mutation in leucine-rich repeat kinase 2 was inhibited by dibutyryl–cyclic adenosine monophosphate, cytoplasmic expression of the PKA catalytic subunit, or the LC3 phosphorylation mimic. These data demonstrate a role for phosphorylation in regulating LC3 activity. PMID:20713600

  1. Method validation for strobilurin fungicides in cereals and fruit

    DEFF Research Database (Denmark)

    Christensen, Hanne Bjerre; Granby, Kit

    2001-01-01

    Strobilurins are a new class of fungicides that are active against a broad spectrum of fungi. In the present work a GC method for analysis of strobilurin fungicides was validated. The method was based on extraction with ethyl acetate/cyclohexane, clean-up by gel permeation chromatography (GPC......) and determination of the content by gas chromatography (GC) with electron capture (EC-), nitrogen/phosphorous (NP-), and mass spectrometric (MS-) detection. Three strobilurins, azoxystrobin, kresoxim-methyl and trifloxystrobin were validated on three matrices, wheat, apple and grapes. The validation was based...

  2. Determination of advanced glycation endproducts by LC-MS/MS in raw and roasted almonds (Prunus dulcis).

    Science.gov (United States)

    Zhang, Gong; Huang, Guangwei; Xiao, Lu; Mitchell, Alyson E

    2011-11-23

    A sensitive and reliable LC-(ESI)MS/MS method was developed and validated for the simultaneous analysis of five common advanced glycation endproducts (AGEs) after enzymatic digestion in raw and roasted almonds. AGEs included carboxymethyl-lysine (CML), carboxyethyl-lysine (CEL), pyralline (Pyr), argpyrimidine (Arg-p), and pentosidine (Pento-s). This method allows accurate quantitation of free and AGE-protein adducts of target AGEs. Results indicate that CML and CEL are found in both raw and roasted almonds. Pyr was identified for the first time in roasted almonds and accounted for 64.4% of free plus bound measured AGEs. Arg-p and Pento-s were below the limit of detection in all almond samples tested. Free AGEs accounted for 1.3-26.8% of free plus bound measured AGEs, indicating that protein-bound forms predominate. The roasting process significantly increased CML, CEL, and Pyr formation, but no significant correlation was observed between these AGEs and roasting temperature.

  3. 76 FR 28664 - Method 301-Field Validation of Pollutant Measurement Methods From Various Waste Media

    Science.gov (United States)

    2011-05-18

    ... . d m = The mean of the paired sample differences. n = Total number of paired samples. 7.4.2 t Test... being compared to a validated test method as part of the Method 301 validation and an audit sample for... tighten the acceptance criteria for the precision of candidate alternative test methods. One commenter...

  4. Entangled Coherent States Generation in two Superconducting LC Circuits

    International Nuclear Information System (INIS)

    Chen Meiyu; Zhang Weimin

    2008-01-01

    We proposed a novel pure electronic (solid state) device consisting of two superconducting LC circuits coupled to a superconducting flux qubit. The entangled coherent states of the two LC modes is generated through the measurement of the flux qubit states. The interaction of the flux qubit and two LC circuits is controlled by the external microwave control lines. The geometrical structure of the LC circuits is adjustable and makes a strong coupling between them achievable. This entangled coherent state generator can be realized by using the conventional microelectronic fabrication techniques which increases the feasibility of the experiment.

  5. Studi Perbedaan Keefektifan Pembelajaran LC-5E dan CIRC Terhadap Kemampuan Pemecahan Masalah Matematika

    Directory of Open Access Journals (Sweden)

    E. Sulastri

    2015-06-01

    Full Text Available membandingkan keefektifan model pembelajaran kooperatif tipe LC-5E (Learning Cycle 5E dan tipe CIRC(Cooperative Integrated Reading and Composition terhadap kemampuan pemecahan masalah matematika peserta didik. Populasi penelitian adalah peserta didik kelas X SMA Negeri 2 Ungaran. Sampel diambil secara cluster random sampling. Data akhir mengenai kemampuan pemecahan masalah diambil menggunakan metode tes. Teknik analisis data menggunakan uji proporsi, uji Anava dan uji lanjut LSD. Hasil penelitian menunjukkan kelas yang dikenai perlakuan pembelajaran LC-5Edan CIRCmencapai ketuntasan belajar. Dari uji Anava diketahui bahwa ada perbedaan rata-rata yang signifikan. Selanjutnya dilakukan uji lanjut LSDmenunjukkan Kelompok Eksperimen 1 paling baik. Simpulan dari penelitian ini adalah model pembelajaran LC-5Elebih efektif dibandingkan tipe CIRC terhadap kemampuan pemecahan masalah peserta didik. Saran yang dapat direkomendasikan adalah pembelajaran LC-5E dapat digunakan sebagai alternatif dalam mengembangkan kemampuan pemecahan masalah peserta didik. The purpose of this research was tocomparethe effectiveness of cooperative learning models type LC-5E (Learning Cycle 5E and type CIRC (Cooperative Integrated Reading and Composition toward students’ mathematic problem solving ability. The population of this research was students grade X of SMA Negeri 2 Ungaran.The samples were taken by cluster random sampling. The final data about students’ problem solving ability were taken used test method. Data were analysed used propotion test, ANOVA test, and LSD test. The result shown that classes that given LC-5E and CIRC learning models achieved mastery learning. From ANOVA test known that the averages are different significantly.From LSD test is known that the experiment group was the best. The conclusions from this research are LC-5E is more effective than CIRC learning model toward students’ problem solving ability. The suggestion is LC-5E model can be

  6. Screening and Identification of Mitragynine and 7-Hydroxymitragynine in Human Urine by LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Hanzhuo Fu

    2015-05-01

    Full Text Available Kratom is a tree planted in Southeast Asia, including Thailand, Malaysia, Myanmar (Burma and elsewhere in the region. A long history of usage and abuse of kratom has led to the classification of kratom as a controlled substance in its native Thailand and other Southeast Asian countries. However, kratom is not controlled in the United States, and the wide availability of kratom on the Internet and in the streets has led to its emergence as an herbal drug of misuse. With the increasing popularity of kratom, efficient protocols are needed to detect kratom use. In this study, a rapid method for the analysis of kratom compounds, mitragynine and 7-hydroxymitragynine, in human urine has been developed and validated using high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS. The chromatographic system employed a 2.6-μm 100 mm × 2.1 mm phenyl-hexyl analytical column and gradient elution with a 0.4-mL/min flow rate of water and acetonitrile as mobile phases. A triple quadrupole mass spectrometer was used as the detector for data acquisition. The analyst was the quantification software. The established method demonstrated linearity of >0.99 for both analytes, and low detection limits were obtained down to 0.002581 ng/mL for mitragynine and 0.06910 ng/mL for 7-hydroxymitragynine. The validated method has been utilized for clinical analysis of urine for the purpose of mitragynine and 7-hydroxymitragynine detection.

  7. Accuracy of the Precision® point-of-care ketone test examined by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in the same fingerstick sample.

    Science.gov (United States)

    Janssen, Marcel J W; Hendrickx, Ben H E; Habets-van der Poel, Carin D; van den Bergh, Joop P W; Haagen, Anton A M; Bakker, Jaap A

    2010-12-01

    The Precision(®) (Abbott Diabetes Care) point-of-care biosensor test strips are widely used by patients with diabetes and clinical laboratories for measurement of plasma β-hydroxybutyrate (β-HB) concentrations in capillary blood samples obtained by fingerstick. In the literature, this procedure has been validated only against the enzymatic determination of β-HB in venous plasma, i.e., the method to which the Precision(®) has been calibrated. In this study, the Precision(®) Xceed was compared to a methodologically different and superior procedure: determination of β-HB by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in capillary blood spots. Blood spots were obtained from the same fingerstick sample from out of which Precision(®) measurements were performed. Linearity was tested by adding varying amounts of standard to an EDTA venous whole blood matrix. The Precision(®) was in good agreement with LC-MS/MS within the measuring range of 0.0-6.0 mmol/L (Passing and Bablok regression: slope=1.20 and no significant intercept, R=0.97, n=59). Surprisingly, the Precision(®) showed non-linearity and full saturation at concentrations above 6.0 mmol/L, which were confirmed by a standard addition experiment. Results obtained at the saturation level varied between 3.0 and 6.5 mmol/L. The Precision(®) β-HB test strips demonstrate good comparison with LC-MS/MS. Inter-individual variation around the saturation level, however, is large. Therefore, we advise reporting readings above 3.0 as >3.0 mmol/L. The test is valid for use in the clinically relevant range of 0.0-3.0 mmol/L.

  8. LC-MS/MS method for simultaneous determination of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin in serum of multiple myeloma patients.

    Science.gov (United States)

    Shu, Chang; Zeng, Tianmei; Gao, Shouhong; Xia, Tianyi; Huang, Lifeng; Zhang, Feng; Chen, Wansheng

    2016-08-15

    Multiple myeloma (MM), a malignant neoplastic serum-cell disorder, has been a serious threat to human health. The determination of 6 commonly used drug concentrations, including thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin, in MM patients was of great clinical interest. Herein, we reported a method for the rapid and simultaneous measurement of the above therapeutics by liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method with solid phase extraction. Analysis was performed on a Waters XBridge(®) BEH C18 column (2.5μm, 2.1 mm×50mm), with formic acid aqueous solution and acetonitrile as the mobile phase at flow rate 0.3mL/min. All analytes showed good correlation coefficients (r>0.996), and LLOQ of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin were 4, 2, 2, 2, 2 and 2ng/mL, respectively. The inter- and intra-day precisions and stability were expressed as variation coefficients within 15% and relative error less than 15%. Dilution effect, carryover and incurred sample reanalysis were investigated according to the 2015 edition Chinese Pharmacopoeia guidelines, as US FDA (2013, revision 1) required. The LC-MS/MS based assay described in this article may improve future clinical studies evaluating common therapeutics for MM treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Development and Validation of a Multiresidue Method for the Determination of Pesticides in Dry Samples (Rice and Wheat Flour) Using Liquid Chromatography/Triple Quadrupole Tandem Mass Spectrometry.

    Science.gov (United States)

    Grande-Martínez, Ángel; Arrebola, Francisco Javier; Moreno, Laura Díaz; Vidal, José Luis Martínez; Frenich, Antonia Garrido

    2015-01-01

    A rapid and sensitive multiresidue method was developed and validated for the determination of around 100 pesticides in dry samples (rice and wheat flour) by ultra-performance LC coupled to a triple quadrupole mass analyzer working in tandem mode (UPLC/QqQ-MS/MS). The sample preparation step was optimized for both matrixes. Pesticides were extracted from rice samples using aqueous ethyl acetate, while aqueous acetonitrile extraction [modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method] was used for wheat flour matrixes. In both cases the extracts were then cleaned up by dispersive solid phase extraction with MgSO4 and primary secondary amine+C18 sorbents. A further cleanup step with Florisil was necessary to remove fat in wheat flour. The method was validated at two concentration levels (3.6 and 40 μg/kg for most compounds), obtaining recoveries ranging from 70 to 120%, intraday and interday precision values≤20% expressed as RSDs, and expanded uncertainty values≤50%. The LOQ values ranged between 3.6 and 20 μg/kg, although it was set at 3.6 μg/kg for the majority of the pesticides. The method was applied to the analysis of 20 real samples, and no pesticides were detected.

  10. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  11. Development, validation and application of a micro-liquid chromatography-tandem mass spectrometry based method for simultaneous quantification of selected protein biomarkers of endothelial dysfunction in murine plasma.

    Science.gov (United States)

    Suraj, Joanna; Kurpińska, Anna; Olkowicz, Mariola; Niedzielska-Andres, Ewa; Smolik, Magdalena; Zakrzewska, Agnieszka; Jasztal, Agnieszka; Sitek, Barbara; Chlopicki, Stefan; Walczak, Maria

    2018-02-05

    The objective of this study was to develop and validate the method based on micro-liquid chromatography-tandem mass spectrometry (microLC/MS-MRM) for simultaneous determination of adiponectin (ADN), von Willebrand factor (vWF), soluble form of vascular cell adhesion molecule 1 (sVCAM-1), soluble form of intercellular adhesion molecule 1 (sICAM-1) and syndecan-1 (SDC-1) in mouse plasma. The calibration range was established from 2.5pmol/mL to 5000pmol/mL for ADN; 5pmol/mL to 5000pmol/mL for vWF; 0.375pmol/mL to 250pmol/mL for sVCAM-1 and sICAM-1; and 0.25pmol/mL to 250pmol/mL for SDC-1. The method was applied to measure the plasma concentration of selected proteins in mice fed high-fat diet (HFD), and revealed the pro-thrombotic status by increased concentration of vWF (1.31±0.17 nmol/mL (Control) vs 1.98±0.09 nmol/mL (HFD), p <0.05) and the dysregulation of adipose tissue metabolism by decreased concentration of ADN (0.62±0.08 nmol/mL (Control) vs 0.37±0.06 nmol/mL (HFD), p <0.05). In conclusion, the microLC/MS-MRM-based method allows for reliable measurements of selected protein biomarkers of endothelial dysfunction in mouse plasma. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Identification of adulterants in a Chinese herbal medicine by LC-HRMS and LC-MS-SPE/NMR and comparative in vivo study with standards in a hypertensive rat model.

    Science.gov (United States)

    Kesting, Julie Regitze; Huang, Jingqi; Sørensen, Dan

    2010-02-05

    Based on anecdotal evidence of anti-hypertensive effect of Gold Nine Soft Capsules, an in vivo study of this complex Chinese "herbal-based" medicine was initiated. Dosage of the content of Gold Nine capsules in spontaneous hypertensive rats showed a remarkably good effect. This led to further investigation of the components of the preparation and eventual identification of three known anti-hypertensive drugs; amlodipine, indapamide and valsartan, which were not declared on the label. Compounds were rapidly identified using LC-HRMS and LC-MS-SPE/NMR, quantified by HPLC, and the in vivo activity of a combination of commercially purchased standards was shown to be equivalent to that of the capsule content. Adulteration of herbal remedies and dietary supplements with synthetic drugs is an increasing problem that may lead to serious adverse effects. LC-MS-SPE/NMR as a method for the rapid identification of such adulterants is highlighted in this case study.

  13. Profiling LC-DAD-ESI-TOF MS method for the determination of phenolic metabolites from avocado (Persea americana).

    Science.gov (United States)

    Hurtado-Fernández, Elena; Carrasco-Pancorbo, Alegría; Fernández-Gutiérrez, Alberto

    2011-03-23

    A powerful HPLC-DAD-ESI-TOF MS method was established for the efficient identification of the chemical constituents in the methanolic extracts of avocado (Persea americana). Separation and detection conditions were optimized by using a standard mix containing 39 compounds belonging to phenolic acids and different categories of flavonoids, analytes that could be potentially present in the avocado extracts. Optimum LC separation was achieved on a Zorbax Eclipse Plus C18 analytical column (4.6×150 mm, 1.8 μm particle size) by gradient elution with water+acetic acid (0.5%) and acetonitrile as mobile phases, at a flow rate of 1.6 mL/min. The detection was carried out by ultraviolet-visible absorption and ESI-TOF MS. The developed method was applied to the study of 3 different varieties of avocado, and 17 compounds were unequivocally identified with standards. Moreover, around 25 analytes were tentatively identified by taking into account the accuracy and isotopic information provided by TOF MS.

  14. Development and Single-Laboratory Validation of a Liquid Chromatography Tandem Mass Spectrometry Method for Quantitation of Tetrodotoxin in Mussels and Oysters.

    Science.gov (United States)

    Turner, Andrew D; Boundy, Michael J; Rapkova, Monika Dhanji

    2017-09-01

    In recent years, evidence has grown for the presence of tetrodotoxin (TTX) in bivalve mollusks, leading to the potential for consumers of contaminated products to be affected by Tetrodotoxin Shellfish Poisoning (TSP). A single-laboratory validation was conducted for the hydrophilic interaction LC (HILIC) tandem MS (MS/MS) analysis of TTX in common mussels and Pacific oysters-the bivalve species that have been found to contain TTXs in the United Kingdom in recent years. The method consists of a single-step dispersive extraction in 1% acetic acid, followed by a carbon SPE cleanup step before dilution and instrumental analysis. The full method was developed as a rapid tool for the quantitation of TTX, as well as for the associated analogs 4-epi-TTX; 5,6,11-trideoxy TTX; 11-nor TTX-6-ol; 5-deoxy TTX; and 4,9-anhydro TTX. The method can also be run as the acquisition of TTX together with paralytic shellfish toxins. Results demonstrated acceptable method performance characteristics for specificity, linearity, recovery, ruggedness, repeatability, matrix variability, and within-laboratory reproducibility for the analysis of TTX. The LOD and LOQ were fit-for-purpose in comparison to the current action limit for TTX enforced in The Netherlands. In addition, aspects of method performance (LOD, LOQ, and within-laboratory reproducibility) were found to be satisfactory for three other TTX analogs (11-nor TTX-6-ol, 5-deoxy TTX, and 4,9-anhydro TTX). The method was found to be practical and suitable for use in regulatory testing, providing rapid turnaround of sample analysis. Plans currently underway on a full collaborative study to validate a HILIC-MS/MS method for paralytic shellfish poisoning toxins will be extended to include TTX in order to generate international acceptance, ultimately for use as an alternative official control testing method should regulatory controls be adopted.

  15. The Value of Qualitative Methods in Social Validity Research

    Science.gov (United States)

    Leko, Melinda M.

    2014-01-01

    One quality indicator of intervention research is the extent to which the intervention has a high degree of social validity, or practicality. In this study, I drew on Wolf's framework for social validity and used qualitative methods to ascertain five middle schoolteachers' perceptions of the social validity of System 44®--a phonics-based reading…

  16. Development of a simple and sensitive liquid chromatography triple quadrupole mass spectrometry (LC-MS/MS) method for the determination of cannabidiol (CBD), Δ9-tetrahydrocannabinol (THC) and its metabolites in rat whole blood after oral administration of a single high dose of CBD.

    Science.gov (United States)

    Palazzoli, Federica; Citti, Cinzia; Licata, Manuela; Vilella, Antonietta; Manca, Letizia; Zoli, Michele; Vandelli, Maria Angela; Forni, Flavio; Cannazza, Giuseppe

    2018-02-20

    The investigation of the possible conversion of cannabidiol (CBD) into Δ 9 -tetrahydrocannabinol (THC) in vivo after oral administration of CBD is reported herein since recent publications suggested a rapid conversion in simulated gastric fluid. To this end, single high dose of CBD (50mg/kg) was administered orally to rats and their blood was collected after 3 and 6h. A highly sensitive and selective LC-MS/MS method was developed and fully validated in compliance with the Scientific Working Group of Forensic Toxicology (SWGTOX) standard practices for method validation in forensic toxicology. This method also involved the optimization of cannabinoids and their metabolites extraction in order to remove co-eluting phospholipids and increase the sensitivity of the MS detection. Neither THC nor its metabolites were detected in rat whole blood after 3 or 6h from CBD administration. After oral administration, the amount of CBD dissolved in olive oil was higher than that absorbed from an ethanolic solution. This could be explained by the protection of lipid excipients towards CBD from acidic gastric juice. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Validation of Land Cover Products Using Reliability Evaluation Methods

    Directory of Open Access Journals (Sweden)

    Wenzhong Shi

    2015-06-01

    Full Text Available Validation of land cover products is a fundamental task prior to data applications. Current validation schemes and methods are, however, suited only for assessing classification accuracy and disregard the reliability of land cover products. The reliability evaluation of land cover products should be undertaken to provide reliable land cover information. In addition, the lack of high-quality reference data often constrains validation and affects the reliability results of land cover products. This study proposes a validation schema to evaluate the reliability of land cover products, including two methods, namely, result reliability evaluation and process reliability evaluation. Result reliability evaluation computes the reliability of land cover products using seven reliability indicators. Process reliability evaluation analyzes the reliability propagation in the data production process to obtain the reliability of land cover products. Fuzzy fault tree analysis is introduced and improved in the reliability analysis of a data production process. Research results show that the proposed reliability evaluation scheme is reasonable and can be applied to validate land cover products. Through the analysis of the seven indicators of result reliability evaluation, more information on land cover can be obtained for strategic decision-making and planning, compared with traditional accuracy assessment methods. Process reliability evaluation without the need for reference data can facilitate the validation and reflect the change trends of reliabilities to some extent.

  18. Metabolic profiling of Vitex agnus castus leaves, fruits and sprouts: analysis by LC/ESI/(QqQ)MS and (HR) LC/ESI/(Orbitrap)/MS n.

    Science.gov (United States)

    Mari, Angela; Montoro, Paola; D'Urso, Gilda; Macchia, Mario; Pizza, Cosimo; Piacente, Sonia

    2015-01-01

    Food supplements based on Vitex agnus castus L. (Verbenaceae) fruits, also known as chasteberry, are routinely used by women against somatic and psychic premenstrual symptoms such as depression, sadness or irritability. With the aim of highlighting the differences in the chemical profiles of cultivated fruits and different parts of wild plants (fruits, leaves and sprouts) of V. agnus castus, a method concerning with the quali-quantitative study of the derived hydroalcoholic extracts was carried out by using high-performance liquid chromatography coupled to electrospray negative ionization Orbitrap multicollisional high resolution mass spectrometry (LC/ESI/(Orbitrap)MS(n)) and high-performance liquid chromatography coupled to electrospray negative ionization triple quadrupole tandem mass spectrometry (LC/ESI/(QqQ)MS) in multiple reaction monitoring (MRM) mode. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. The co-feature ratio, a novel method for the measurement of chromatographic and signal selectivity in LC-MS-based metabolomics

    International Nuclear Information System (INIS)

    Elmsjö, Albert; Haglöf, Jakob; Engskog, Mikael K.R.; Nestor, Marika; Arvidsson, Torbjörn; Pettersson, Curt

    2017-01-01

    Evaluation of analytical procedures, especially in regards to measuring chromatographic and signal selectivity, is highly challenging in untargeted metabolomics. The aim of this study was to suggest a new straightforward approach for a systematic examination of chromatographic and signal selectivity in LC-MS-based metabolomics. By calculating the ratio between each feature and its co-eluting features (the co-features), a measurement of the chromatographic selectivity (i.e. extent of co-elution) as well as the signal selectivity (e.g. amount of adduct formation) of each feature could be acquired, the co-feature ratio. This approach was used to examine possible differences in chromatographic and signal selectivity present in samples exposed to three different sample preparation procedures. The capability of the co-feature ratio was evaluated both in a classical targeted setting using isotope labelled standards as well as without standards in an untargeted setting. For the targeted analysis, several metabolites showed a skewed quantitative signal due to poor chromatographic selectivity and/or poor signal selectivity. Moreover, evaluation of the untargeted approach through multivariate analysis of the co-feature ratios demonstrated the possibility to screen for metabolites displaying poor chromatographic and/or signal selectivity characteristics. We conclude that the co-feature ratio can be a useful tool in the development and evaluation of analytical procedures in LC-MS-based metabolomics investigations. Increased selectivity through proper choice of analytical procedures may decrease the false positive and false negative discovery rate and thereby increase the validity of any metabolomic investigation. - Highlights: • The co-feature ratio (CFR) is introduced. • CFR measures chromatographic and signal selectivity of a feature. • CFR can be used for evaluating experimental procedures in metabolomics. • CFR can aid in locating features with poor selectivity.

  20. The co-feature ratio, a novel method for the measurement of chromatographic and signal selectivity in LC-MS-based metabolomics

    Energy Technology Data Exchange (ETDEWEB)

    Elmsjö, Albert, E-mail: Albert.Elmsjo@farmkemi.uu.se [Department of Medicinal Chemistry, Division of Analytical Pharmaceutical Chemistry, Uppsala University (Sweden); Haglöf, Jakob; Engskog, Mikael K.R. [Department of Medicinal Chemistry, Division of Analytical Pharmaceutical Chemistry, Uppsala University (Sweden); Nestor, Marika [Department of Immunology, Genetics and Pathology, Uppsala University (Sweden); Arvidsson, Torbjörn [Department of Medicinal Chemistry, Division of Analytical Pharmaceutical Chemistry, Uppsala University (Sweden); Medical Product Agency, Uppsala (Sweden); Pettersson, Curt [Department of Medicinal Chemistry, Division of Analytical Pharmaceutical Chemistry, Uppsala University (Sweden)

    2017-03-01

    Evaluation of analytical procedures, especially in regards to measuring chromatographic and signal selectivity, is highly challenging in untargeted metabolomics. The aim of this study was to suggest a new straightforward approach for a systematic examination of chromatographic and signal selectivity in LC-MS-based metabolomics. By calculating the ratio between each feature and its co-eluting features (the co-features), a measurement of the chromatographic selectivity (i.e. extent of co-elution) as well as the signal selectivity (e.g. amount of adduct formation) of each feature could be acquired, the co-feature ratio. This approach was used to examine possible differences in chromatographic and signal selectivity present in samples exposed to three different sample preparation procedures. The capability of the co-feature ratio was evaluated both in a classical targeted setting using isotope labelled standards as well as without standards in an untargeted setting. For the targeted analysis, several metabolites showed a skewed quantitative signal due to poor chromatographic selectivity and/or poor signal selectivity. Moreover, evaluation of the untargeted approach through multivariate analysis of the co-feature ratios demonstrated the possibility to screen for metabolites displaying poor chromatographic and/or signal selectivity characteristics. We conclude that the co-feature ratio can be a useful tool in the development and evaluation of analytical procedures in LC-MS-based metabolomics investigations. Increased selectivity through proper choice of analytical procedures may decrease the false positive and false negative discovery rate and thereby increase the validity of any metabolomic investigation. - Highlights: • The co-feature ratio (CFR) is introduced. • CFR measures chromatographic and signal selectivity of a feature. • CFR can be used for evaluating experimental procedures in metabolomics. • CFR can aid in locating features with poor selectivity.

  1. Validation of a high-performance liquid chromatographic method with UV detection for the determination of ethopabate residues in poultry liver.

    Science.gov (United States)

    Granja, Rodrigo H M M; Niño, Alfredo M Montes; Zucchetti, Roberto A M; Niño, Rosario E Montes; Salerno, Alessandro G

    2008-01-01

    Ethopabate is frequently used in the prophylaxis and treatment of coccidiosis in poultry. Residues of this drug in food present a potential risk to consumers. A simple, rapid, and sensitive column high-performance liquid chromatographic (HPLC) method with UV detection for determination of ethopabate in poultry liver is presented. The drug is extracted with acetonitrile. After evaporation, the residue is dissolved with an acetone-hexane mixture and cleaned up by solid-phase extraction using Florisil columns. The analyte is then eluted with methanol. LC analysis is carried out on a C18 5 microm Gemini column, 15 cm x 4.6 mm. Ethopabate is quantified by means of UV detection at 270 nm. Parameters such as decision limit, detection capability, precision, recovery, ruggedness, and measurement uncertainty were calculated according to method validation guidelines provided in 2002/657/EC and ISO/IEC 17025:2005. Decision limit and detection capability were determined to be 2 and 3 microg/kg, respectively. Average recoveries from poultry samples fortified with 10, 15, and 20 microg/kg levels of ethopabate were 100-105%. A complete statistical analysis was performed on the results obtained, including an estimation of the method uncertainty. The method is to be implemented into Brazil's residue monitoring and control program for ethopabate.

  2. EFEKTIVITAS PEMBELAJARAN LC 5E UNTUK MENGURANGI KESALAHAN KONSEP MATERI REDOKS DAN RETENSINYA PADA SISWA KELAS X

    Directory of Open Access Journals (Sweden)

    Noni Asmarisa

    2017-09-01

    Full Text Available This study aims to (1 identify students’ misconceptions in redox (2 determine the effectiveness of LC 5E learning model in correcting student’ misconceptions in redox; and (3 determine its retention after correction of student’ misconceptions in redox with LC 5E learning model. This research is descriptive and pre-experimental. Descriptive study was used to identify and describe the misconceptions students on redox material, while pre-experimental was used to  study on the effectiveness of LC 5E learning model in correcting misconceptions and determine its retention. Subject in this study is a science class (X IPA 1 SMA of Al Muhafidzoh Blitar which consists of 20 students who have learned redox. The misconceptions were observed using a diagnostic test, 15 items of multiple-choice questions with reasoned. The test has validity of 97% and reliability value of 0.934..  The results showed that (1 students has following 14 misconceptions in redox; (2 The LC 5E learning model is effective in improving students' misconceptions in redox reaction with an average reduction of 78.78%; (3 retention of students' understanding of the concept after two weeks of repairs using LC 5E learning model is 95.6%, which is classified in the category very well. Penelitian ini bertujuan untuk (1 mengidentifikasi kesalahan konsep siswa pada materi redoks; (2 mengetahui keefektifan model pembelajaran LC 5E dalam memperbaiki kesalahan konsep redoks; dan (3 mengetahui retensinya setelah dilakukan perbaikan dengan model pembelajaran LC 5E. Penelitian ini bersifat deskriptif dan pra-eksperimental. Penelitian deskriptif digunakan untuk mengidentifikasi dan mendeskripsikan kesalahan konsep siswa pada materi redoks. Penelitian pra-eksperimental digunakan untuk melihat keefektifan model pembelajaran LC 5E dalam memperbaiki kesalahan konsep dan mengetahui retensinya. Subjek penelitian dalam penelitian ini adalah siswa kelas X IPA 1 SMA Al Muhafidzoh Blitar yang berjumlah

  3. High-throughput fragment screening by affinity LC-MS.

    Science.gov (United States)

    Duong-Thi, Minh-Dao; Bergström, Maria; Fex, Tomas; Isaksson, Roland; Ohlson, Sten

    2013-02-01

    Fragment screening, an emerging approach for hit finding in drug discovery, has recently been proven effective by its first approved drug, vemurafenib, for cancer treatment. Techniques such as nuclear magnetic resonance, surface plasmon resonance, and isothemal titration calorimetry, with their own pros and cons, have been employed for screening fragment libraries. As an alternative approach, screening based on high-performance liquid chromatography separation has been developed. In this work, we present weak affinity LC/MS as a method to screen fragments under high-throughput conditions. Affinity-based capillary columns with immobilized thrombin were used to screen a collection of 590 compounds from a fragment library. The collection was divided into 11 mixtures (each containing 35 to 65 fragments) and screened by MS detection. The primary screening was performed in 3500 fragments per day). Thirty hits were defined, which subsequently entered a secondary screening using an active site-blocked thrombin column for confirmation of specificity. One hit showed selective binding to thrombin with an estimated dissociation constant (K (D)) in the 0.1 mM range. This study shows that affinity LC/MS is characterized by high throughput, ease of operation, and low consumption of target and fragments, and therefore it promises to be a valuable method for fragment screening.

  4. Validation and global uncertainty of a liquid chromatographic with diode array detection method for the screening of azoxystrobin, kresoxim-methyl, trifloxystrobin, famoxadone, pyraclostrobin and fenamidone in grapes and wine.

    Science.gov (United States)

    de Melo Abreu, Susana; Caboni, Pierluigi; Cabras, Paolo; Garau, Vincenzo Luigi; Alves, Arminda

    2006-07-28

    Azoxystrobin, kresoxim-methyl, trifloxystrobin, pyraclostrobin, famoxadone and fenamidone are permitted Q(o) Inhibitor (Q(o)I) fungicides applied to vine in some European countries for the treatment of downy and powdery mildews. In this work, a method is validated for the analysis of these fungicides in grapes and wine. This screening method consists in a simple one step liquid-liquid extraction followed by liquid chromatography (LC) fitted with a diode array detector (DAD). Limits of detection for grapes and wine were below 0.2 mg kg(-1) or mg l(-1), precision was not above 13%, and recoveries were, on average, 95+/-5% for grapes and 104+/-6% for wine. Global uncertainties evaluated in the concentration range from 0.25 to 2.50 mg l(-1) were below 20%. A confirmatory method by gas chromatography (GC) with mass spectrometry (MS) detection was used.

  5. An application of the LC-LSTM framework to the self-esteem instability case.

    Science.gov (United States)

    Alessandri, Guido; Vecchione, Michele; Donnellan, Brent M; Tisak, John

    2013-10-01

    The present research evaluates the stability of self-esteem as assessed by a daily version of the Rosenberg (Society and the adolescent self-image, Princeton University Press, Princeton, 1965) general self-esteem scale (RGSE). The scale was administered to 391 undergraduates for five consecutive days. The longitudinal data were analyzed using the integrated LC-LSTM framework that allowed us to evaluate: (1) the measurement invariance of the RGSE, (2) its stability and change across the 5-day assessment period, (3) the amount of variance attributable to stable and transitory latent factors, and (4) the criterion-related validity of these factors. Results provided evidence for measurement invariance, mean-level stability, and rank-order stability of daily self-esteem. Latent state-trait analyses revealed that variances in scores of the RGSE can be decomposed into six components: stable self-esteem (40 %), ephemeral (or temporal-state) variance (36 %), stable negative method variance (9 %), stable positive method variance (4 %), specific variance (1 %) and random error variance (10 %). Moreover, latent factors associated with daily self-esteem were associated with measures of depression, implicit self-esteem, and grade point average.

  6. Solution Structure of LC4 Transmembrane Segment of CCR5

    OpenAIRE

    Miyamoto, Kazuhide; Togiya, Kayo

    2011-01-01

    CC-chemokine receptor 5 (CCR5) is a specific co-receptor allowing the entry of human immunodeficiency virus type 1 (HIV-1). The LC4 region in CCR5 is required for HIV-1 entry into the cells. In this study, the solution structure of LC4 in SDS micelles was elucidated by using standard 1H two-dimensional NMR spectroscopy, circular dichroism, and fluorescdence quenching. The LC4 structure adopts two helical structures, whereas the C-terminal part remains unstructured. The positions in which LC4 ...

  7. Development, validation and clinical application of an online-SPE-LC-HRMS/MS for simultaneous quantification of phenobarbital, phenytoin, carbamazepine, and its active metabolite carbamazepine 10,11-epoxide.

    Science.gov (United States)

    Qu, Lihua; Fan, Yuanjie; Wang, Wenjun; Ma, Kai; Yin, Zheng

    2016-09-01

    A simple and efficient bioanalytical method for simultaneous determination of phenobarbital (PB), phenytoin (PHT), carbamazepine (CBZ), and its active metabolite carbamazepine 10,11-epoxide (CBZE) in human plasma using online solid phase extraction (SPE)-liquid chromatography (LC) coupled with high resolution mass spectrum (HRMS) under targeted MS/MS (t-MS(2)) analysis mode has been developed. The procedure integrated an automated sample clean-up of human plasma by Oasis®HLB SPE cartridge, a separation by ZORBAX SB-C18 analysis column, and a quantification by Q-Exactive Hybrid Quadrupole-Orbitrap. The total running time was 13min. The lower limit of quantification (LLOQ) of PB, PHT, CBZ, and CBZE were 0.008, 0.008, 0.0016 and 0.0016μgmL(-1) respectively and the linearities were in the range of 0.008-2.500, 0.008-2.500, 0.0016-0.500 and 0.0016-0.500μgmL(-1) respectively. The mean recovery was between 91.82% and 108.27% and the matrix effect was between 93.29% and 102.09%. The relative standard deviations of interday and intraday were less than 6.41%. The method has been successfully applied in therapeutic drug monitoring (TDM) of four Chinese epilepsy patients. This fully automated, simple, sensitive and reliable online-SPE-LC-HRMS/MS method serves well for TDM of PB, PHT, CBZ and CBZE at clinics for either single or combination treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.

    Science.gov (United States)

    Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno

    2016-06-01

    A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. A surrogate analyte-based LC-MS/MS method for the determination of γ-hydroxybutyrate (GHB) in human urine and variation of endogenous urinary concentrations of GHB.

    Science.gov (United States)

    Kang, Soyoung; Oh, Seung Min; Chung, Kyu Hyuck; Lee, Sooyeun

    2014-09-01

    γ-Hydroxybutyrate (GHB) is a drug of abuse with a strong anesthetic effect; however, proving its ingestion through the quantification of GHB in biological specimens is not straightforward due to the endogenous presence of GHB in human blood, urine, saliva, etc. In the present study, a surrogate analyte approach was applied to accurate quantitative determination of GHB in human urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in order to overcome this issue. For this, (2)H6-GHB and (13)C2-dl-3-hydroxybutyrate were used as a surrogate standard and as an internal standard, respectively, and parallelism between the surrogate analyte approach and standard addition was investigated at the initial step. The validation results proved the method to be selective, accurate, and precise, with acceptable linearity within calibration ranges (0.1-1μg/ml). The limit of detection and the limit of quantification of (2)H6-GHB were 0.05 and 0.1μg/ml, respectively. No significant variations were observed among urine matrices from different sources. The stability of (2)H6-GHB was satisfactory under sample storage and in-process conditions. However, in vitro production of endogenous GHB was observed when the urine sample was kept under the in-process condition for 4h and under the storage conditions of 4 and -20°C. In order to facilitate the practical interpretation of urinary GHB, endogenous GHB was accurately measured in urine samples from 79 healthy volunteers using the surrogate analyte-based LC-MS/MS method developed in the present study. The unadjusted and creatinine-adjusted GHB concentrations in 74 urine samples with quantitative results ranged from 0.09 to 1.8μg/ml and from 4.5 to 530μg/mmol creatinine, respectively. No significant correlation was observed between the unadjusted and creatinine-adjusted GHB concentrations. The urinary endogenous GHB concentrations were affected by gender and age while they were not significantly influenced by habitual

  10. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  11. Quantitative Analysis of Tetramethylenedisulfotetramine ('Tetramine') Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    International Nuclear Information System (INIS)

    Owens, J.; Hok, S.; Alcaraz, A.; Koester, C.

    2008-01-01

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD 50 = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 (micro)g/mL by LC/MS/MS versus 0.15 (micro)g/mL for GC/MS. Fortifications of the beverages at 2.5 (micro)g/mL and 0.25 (micro)g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  12. Electron ionization LC-MS with supersonic molecular beams--the new concept, benefits and applications.

    Science.gov (United States)

    Seemann, Boaz; Alon, Tal; Tsizin, Svetlana; Fialkov, Alexander B; Amirav, Aviv

    2015-11-01

    A new type of electron ionization LC-MS with supersonic molecular beams (EI-LC-MS with SMB) is described. This system and its operational methods are based on pneumatic spray formation of the LC liquid flow in a heated spray vaporization chamber, full sample thermal vaporization and subsequent electron ionization of vibrationally cold molecules in supersonic molecular beams. The vaporized sample compounds are transferred into a supersonic nozzle via a flow restrictor capillary. Consequently, while the pneumatic spray is formed and vaporized at above atmospheric pressure the supersonic nozzle backing pressure is about 0.15 Bar for the formation of supersonic molecular beams with vibrationally cold sample molecules without cluster formation with the solvent vapor. The sample compounds are ionized in a fly-though EI ion source as vibrationally cold molecules in the SMB, resulting in 'Cold EI' (EI of vibrationally cold molecules) mass spectra that exhibit the standard EI fragments combined with enhanced molecular ions. We evaluated the EI-LC-MS with SMB system and demonstrated its effectiveness in NIST library sample identification which is complemented with the availability of enhanced molecular ions. The EI-LC-MS with SMB system is characterized by linear response of five orders of magnitude and uniform compound independent response including for non-polar compounds. This feature improves sample quantitation that can be approximated without compound specific calibration. Cold EI, like EI, is free from ion suppression and/or enhancement effects (that plague ESI and/or APCI) which facilitate faster LC separation because full separation is not essential. The absence of ion suppression effects enables the exploration of fast flow injection MS-MS as an alternative to lengthy LC-MS analysis. These features are demonstrated in a few examples, and the analysis of the main ingredients of Cannabis on a few Cannabis flower extracts is demonstrated. Finally, the advantages of

  13. Development of a liquid chromatography–tandem mass spectrometry method for the determination of sulfonamides, trimethoprim and dapsone in honey and validation according to Commission Decision 2002/657/EC for banned compounds [corrected].

    Science.gov (United States)

    Economou, Anastasios; Petraki, Olympia; Tsipi, Despina; Botitsi, Eleni

    2012-08-15

    This work reports a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for identification and quantification of seven sulfonamides, trimethoprim and dapsone in honey. The method is based on a solid-phase extraction (SPE) step of the target analytes with Oasis HLB cartridges after acidic hydrolysis of the honey sample to liberate the sugar-bound sulfonamides. Analysis was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive electro-spray ionization (ESI) mode with two different isotopically labeled internal standards with the view to improve the quantitative performance of the method. The method validation has been performed according to the Commission Decision 2002/657/EC; the average recoveries, measured at three concentration levels (1.5, 2.5 and 5.0 μg kg(-1)), have been estimated in the range 70 to 106% while the respective % relative standard deviations of the within-laboratory reproducibility ranged from 6 to 18%. Mean values of the expanded uncertainties calculated were in the range 22-41% at the 99% confidence level. Decision limit (CCα) and detection capability (CCβ) values were in the ranges 0.4-0.9 and 0.7-1.4 μg kg(-1), respectively. Matrix effects have been investigated demonstrating a moderate signal suppression/enhancement for most of the target compounds. The method described has been successfully applied to the analysis of honey samples; sulfamethoxazole, sulfathiazole and trimethoprim were detected in some cases. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. International Harmonization and Cooperation in the Validation of Alternative Methods.

    Science.gov (United States)

    Barroso, João; Ahn, Il Young; Caldeira, Cristiane; Carmichael, Paul L; Casey, Warren; Coecke, Sandra; Curren, Rodger; Desprez, Bertrand; Eskes, Chantra; Griesinger, Claudius; Guo, Jiabin; Hill, Erin; Roi, Annett Janusch; Kojima, Hajime; Li, Jin; Lim, Chae Hyung; Moura, Wlamir; Nishikawa, Akiyoshi; Park, HyeKyung; Peng, Shuangqing; Presgrave, Octavio; Singer, Tim; Sohn, Soo Jung; Westmoreland, Carl; Whelan, Maurice; Yang, Xingfen; Yang, Ying; Zuang, Valérie

    The development and validation of scientific alternatives to animal testing is important not only from an ethical perspective (implementation of 3Rs), but also to improve safety assessment decision making with the use of mechanistic information of higher relevance to humans. To be effective in these efforts, it is however imperative that validation centres, industry, regulatory bodies, academia and other interested parties ensure a strong international cooperation, cross-sector collaboration and intense communication in the design, execution, and peer review of validation studies. Such an approach is critical to achieve harmonized and more transparent approaches to method validation, peer-review and recommendation, which will ultimately expedite the international acceptance of valid alternative methods or strategies by regulatory authorities and their implementation and use by stakeholders. It also allows achieving greater efficiency and effectiveness by avoiding duplication of effort and leveraging limited resources. In view of achieving these goals, the International Cooperation on Alternative Test Methods (ICATM) was established in 2009 by validation centres from Europe, USA, Canada and Japan. ICATM was later joined by Korea in 2011 and currently also counts with Brazil and China as observers. This chapter describes the existing differences across world regions and major efforts carried out for achieving consistent international cooperation and harmonization in the validation and adoption of alternative approaches to animal testing.

  15. The Method of Manufactured Universes for validating uncertainty quantification methods

    KAUST Repository

    Stripling, H.F.

    2011-09-01

    The Method of Manufactured Universes is presented as a validation framework for uncertainty quantification (UQ) methodologies and as a tool for exploring the effects of statistical and modeling assumptions embedded in these methods. The framework calls for a manufactured reality from which experimental data are created (possibly with experimental error), an imperfect model (with uncertain inputs) from which simulation results are created (possibly with numerical error), the application of a system for quantifying uncertainties in model predictions, and an assessment of how accurately those uncertainties are quantified. The application presented in this paper manufactures a particle-transport universe, models it using diffusion theory with uncertain material parameters, and applies both Gaussian process and Bayesian MARS algorithms to make quantitative predictions about new experiments within the manufactured reality. The results of this preliminary study indicate that, even in a simple problem, the improper application of a specific UQ method or unrealized effects of a modeling assumption may produce inaccurate predictions. We conclude that the validation framework presented in this paper is a powerful and flexible tool for the investigation and understanding of UQ methodologies. © 2011 Elsevier Ltd. All rights reserved.

  16. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry. ... Tropical Journal of Pharmaceutical Research ... Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with ...

  17. Exploring on the Sensitivity Changes of the LC Resonance Magnetic Sensors Affected by Superposed Ringing Signals.

    Science.gov (United States)

    Lin, Tingting; Zhou, Kun; Yu, Sijia; Wang, Pengfei; Wan, Ling; Zhao, Jing

    2018-04-25

    LC resonance magnetic sensors are widely used in low-field nuclear magnetic resonance (LF-NMR) and surface nuclear magnetic resonance (SNMR) due to their high sensitivity, low cost and simple design. In magnetically shielded rooms, LC resonance magnetic sensors can exhibit sensitivities at the fT/√Hz level in the kHz range. However, since the equivalent magnetic field noise of this type of sensor is greatly affected by the environment, weak signals are often submerged in practical applications, resulting in relatively low signal-to-noise ratios (SNRs). To determine why noise increases in unshielded environments, we analysed the noise levels of an LC resonance magnetic sensor ( L ≠ 0) and a Hall sensor ( L ≈ 0) in different environments. The experiments and simulations indicated that the superposed ringing of the LC resonance magnetic sensors led to the observed increase in white noise level caused by environmental interference. Nevertheless, ringing is an inherent characteristic of LC resonance magnetic sensors. It cannot be eliminated when environmental interference exists. In response to this problem, we proposed a method that uses matching resistors with various values to adjust the quality factor Q of the LC resonance magnetic sensor in different measurement environments to obtain the best sensitivity. The LF-NMR experiment in the laboratory showed that the SNR is improved significantly when the LC resonance magnetic sensor with the best sensitivity is selected for signal acquisition in the light of the test environment. (When the matching resistance is 10 kΩ, the SNR is 3.46 times that of 510 Ω). This study improves LC resonance magnetic sensors for nuclear magnetic resonance (NMR) detection in a variety of environments.

  18. OWL-based reasoning methods for validating archetypes.

    Science.gov (United States)

    Menárguez-Tortosa, Marcos; Fernández-Breis, Jesualdo Tomás

    2013-04-01

    Some modern Electronic Healthcare Record (EHR) architectures and standards are based on the dual model-based architecture, which defines two conceptual levels: reference model and archetype model. Such architectures represent EHR domain knowledge by means of archetypes, which are considered by many researchers to play a fundamental role for the achievement of semantic interoperability in healthcare. Consequently, formal methods for validating archetypes are necessary. In recent years, there has been an increasing interest in exploring how semantic web technologies in general, and ontologies in particular, can facilitate the representation and management of archetypes, including binding to terminologies, but no solution based on such technologies has been provided to date to validate archetypes. Our approach represents archetypes by means of OWL ontologies. This permits to combine the two levels of the dual model-based architecture in one modeling framework which can also integrate terminologies available in OWL format. The validation method consists of reasoning on those ontologies to find modeling errors in archetypes: incorrect restrictions over the reference model, non-conformant archetype specializations and inconsistent terminological bindings. The archetypes available in the repositories supported by the openEHR Foundation and the NHS Connecting for Health Program, which are the two largest publicly available ones, have been analyzed with our validation method. For such purpose, we have implemented a software tool called Archeck. Our results show that around 1/5 of archetype specializations contain modeling errors, the most common mistakes being related to coded terms and terminological bindings. The analysis of each repository reveals that different patterns of errors are found in both repositories. This result reinforces the need for making serious efforts in improving archetype design processes. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Quantitative evaluation of the matrix effect in bioanalytical methods based on LC-MS: A comparison of two approaches.

    Science.gov (United States)

    Rudzki, Piotr J; Gniazdowska, Elżbieta; Buś-Kwaśnik, Katarzyna

    2018-06-05

    Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful tool for studying pharmacokinetics and toxicokinetics. Reliable bioanalysis requires the characterization of the matrix effect, i.e. influence of the endogenous or exogenous compounds on the analyte signal intensity. We have compared two methods for the quantitation of matrix effect. The CVs(%) of internal standard normalized matrix factors recommended by the European Medicines Agency were evaluated against internal standard normalized relative matrix effects derived from Matuszewski et al. (2003). Both methods use post-extraction spiked samples, but matrix factors require also neat solutions. We have tested both approaches using analytes of diverse chemical structures. The study did not reveal relevant differences in the results obtained with both calculation methods. After normalization with the internal standard, the CV(%) of the matrix factor was on average 0.5% higher than the corresponding relative matrix effect. The method adopted by the European Medicines Agency seems to be slightly more conservative in the analyzed datasets. Nine analytes of different structures enabled a general overview of the problem, still, further studies are encouraged to confirm our observations. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method

    Institute of Scientific and Technical Information of China (English)

    Cai Sheng Wu; Bao Lin Guo; Yu Xin Sheng; Jin Lan Zhang

    2008-01-01

    In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-0-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.

  1. Development and Validation of Improved Method for Fingerprint ...

    African Journals Online (AJOL)

    Purpose: To develop and validate an improved method by capillary zone electrophoresis with photodiode array detection for the fingerprint analysis of Ligusticum chuanxiong Hort. (Rhizoma Chuanxiong). Methods: The optimum high performance capillary electrophoresis (HPCE) conditions were 30 mM borax containing 5 ...

  2. Validity of a food frequency questionnaire to estimate long-chain polyunsaturated fatty acid intake among Japanese women in early and late pregnancy.

    Science.gov (United States)

    Kobayashi, Minatsu; Jwa, Seung Chik; Ogawa, Kohei; Morisaki, Naho; Fujiwara, Takeo

    2017-01-01

    The relative validity of food frequency questionnaires for estimating long-chain polyunsaturated fatty acid (LC-PUFA) intake among pregnant Japanese women is currently unclear. The aim of this study was to verify the external validity of a food frequency questionnaire, originally developed for non-pregnant adults, to assess the dietary intake of LC-PUFA using dietary records and serum phospholipid levels among Japanese women in early and late pregnancy. A validation study involving 188 participants in early pregnancy and 169 participants in late pregnancy was conducted. Intake LC-PUFA was estimated using a food frequency questionnaire and evaluated using a 3-day dietary record and serum phospholipid concentrations in both early and late pregnancy. The food frequency questionnaire provided estimates of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) intake with higher precision than dietary records in both early and late pregnancy. Significant correlations were observed for LC-PUFA intake estimated using dietary records in both early and late pregnancy, particularly for EPA and DHA (correlation coefficients ranged from 0.34 to 0.40, p food frequency questionnaire, which was originally designed for non-pregnant adults and was evaluated in this study against dietary records and biological markers, has good validity for assessing LC-PUFA intake, especially EPA and DHA intake, among Japanese women in early and late pregnancy. Copyright © 2016 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  3. Quantitative bioanalysis of antibody-conjugated payload in monkey plasma using a hybrid immuno-capture LC-MS/MS approach: Assay development, validation, and a case study.

    Science.gov (United States)

    Liu, Ang; Kozhich, Alexander; Passmore, David; Gu, Huidong; Wong, Richard; Zambito, Frank; Rangan, Vangipuram S; Myler, Heather; Aubry, Anne-Françoise; Arnold, Mark E; Wang, Jian

    2015-10-01

    Antibody drug conjugates (ADCs) are complex molecules composed of two pharmacologically distinct components, the cytotoxic payload and the antibody. The measurement of the payload molecules that are attached to the antibody in vivo is important for the evaluation of the safety and efficacy of ADCs, and can also provide distinct information compared to the antibody-related analytes. However, analyzing the antibody-conjugated payload is challenging and in some cases may not be feasible. The in vivo change in drug antibody ratio (DAR), due to deconjugation, biotransformation or other clearance phenomena, generates unique and additional challenges for ADC analysis in biological samples. Here, we report a novel hybrid approach with immuno-capture of the ADC, payload cleavage by specific enzyme, and LC-MS/MS of the cleaved payload to quantitatively measure the concentration of payload molecules still attached to the antibody via linker in plasma. The ADC reference material used for the calibration curve is not likely to be identical to the ADC measured in study samples due to the change in DAR distribution over the PK time course. The assay clearly demonstrated that there was no bias in the measurement of antibody-conjugated payload for ADC with varying DAR, which thus allowed accurate quantification even when the DAR distribution dynamically changes in vivo. This hybrid assay was fully validated based on a combination of requirements for both chromatographic and ligand binding methods, and was successfully applied to support a GLP safety study in monkeys. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. GeLC-MS: A Sample Preparation Method for Proteomics Analysis of Minimal Amount of Tissue.

    Science.gov (United States)

    Makridakis, Manousos; Vlahou, Antonia

    2017-10-10

    Application of various proteomics methodologies have been implemented for the global and targeted proteome analysis of many different types of biological samples such as tissue, urine, plasma, serum, blood, and cell lines. Among the aforementioned biological samples, tissue has an exceptional role into clinical research and practice. Disease initiation and progression is usually located at the tissue level of different organs, making the analysis of this material very important for the understanding of the disease pathophysiology. Despite the significant advances in the mass spectrometry instrumentation, tissue proteomics still faces several challenges mainly due to increased sample complexity and heterogeneity. However, the most prominent challenge is attributed to the invasive procedure of tissue sampling which restricts the availability of fresh frozen tissue to minimal amounts and limited number of samples. Application of GeLC-MS sample preparation protocol for tissue proteomics analysis can greatly facilitate making up for these difficulties. In this chapter, a step by step guide for the proteomics analysis of minute amounts of tissue samples using the GeLC-MS sample preparation protocol, as applied by our group in the analysis of multiple different types of tissues (vessels, kidney, bladder, prostate, heart) is provided.

  5. Method validation for chemical composition determination by electron microprobe with wavelength dispersive spectrometer

    Science.gov (United States)

    Herrera-Basurto, R.; Mercader-Trejo, F.; Muñoz-Madrigal, N.; Juárez-García, J. M.; Rodriguez-López, A.; Manzano-Ramírez, A.

    2016-07-01

    The main goal of method validation is to demonstrate that the method is suitable for its intended purpose. One of the advantages of analytical method validation is translated into a level of confidence about the measurement results reported to satisfy a specific objective. Elemental composition determination by wavelength dispersive spectrometer (WDS) microanalysis has been used over extremely wide areas, mainly in the field of materials science, impurity determinations in geological, biological and food samples. However, little information is reported about the validation of the applied methods. Herein, results of the in-house method validation for elemental composition determination by WDS are shown. SRM 482, a binary alloy Cu-Au of different compositions, was used during the validation protocol following the recommendations for method validation proposed by Eurachem. This paper can be taken as a reference for the evaluation of the validation parameters more frequently requested to get the accreditation under the requirements of the ISO/IEC 17025 standard: selectivity, limit of detection, linear interval, sensitivity, precision, trueness and uncertainty. A model for uncertainty estimation was proposed including systematic and random errors. In addition, parameters evaluated during the validation process were also considered as part of the uncertainty model.

  6. Rapid and Sensitive Determination of Timosaponin AIII in Rat Plasma by LC-MS/MS and Its Pharmacokinetic Application

    Directory of Open Access Journals (Sweden)

    Zhenzhen Cai

    2013-02-01

    Full Text Available A rapid sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method was developed for determination of timosaponin AIII (TA-III in rat plasma, using ginsenoside Re as an internal standard (IS. TA-III and the IS were detected in MRM mode with a negative ionization electrospray mass spectrometer. The calibration curves were linear over the concentration ranges from 11.14 to 1114 ng/mL and the lower limit of quantification (LLOQ was 11.14 ng/mL. Intra-day and inter-day precisions (RSD were within 10%, and accuracy ranged from 6.4% to 9.1%. The extraction recovery at three concentrations ranged from 92.3% to 95.5%. The validated method was successfully applied to monitor the concentrations of TA-III in rat plasma after intragastric administration. The best fit pharmacokinetic model to estimate the pharmacokinetic parameters was a single compartment model with weight of 1/x2 for oral administration groups of rats for TA-III.

  7. Larix decidua Bark as a Source of Phytoconstituents: An LC-MS Study

    Directory of Open Access Journals (Sweden)

    Valeria Baldan

    2017-11-01

    Full Text Available Larix decidua bark is a waste of the timber industry and is widely diffused in Northern Italy. This material can be considered a good source of antioxidants and phytoconstituents with possible use in cosmetic or nutraceutical products. In this study, simple extraction of larch bark was performed using mixtures of ethanol/water. Furthermore, the phytochemical composition of larch bark extract was studied using LC-MSn methods and the main constituents were identified as flavonoids, spiro-polyphenols, and procyanidins. To confirm the identification by LC-MS semi-preparative HPLC was performed in order to isolate the main constituents and verify the structures by 1H-NMR. Antioxidant properties were studied using an in vitro approach combining DPPH assay and LC-MS in order to establish different roles of the various classes of phytochemicasl of the extract. DPPH activity of some of the isolated compounds was also assessed. The overall results indicate this waste material as a good source of antioxidant compounds, mainly procyanidins, whichresulted the most active constituents in the DPPH assay.

  8. Development and validation of a spectroscopic method for the ...

    African Journals Online (AJOL)

    Development and validation of a spectroscopic method for the simultaneous analysis of ... advanced analytical methods such as high pressure liquid ..... equipment. DECLARATIONS ... high-performance liquid chromatography. J Chromatogr.

  9. Comparison of two-concentration with multi-concentration linear regressions: Retrospective data analysis of multiple regulated LC-MS bioanalytical projects.

    Science.gov (United States)

    Musuku, Adrien; Tan, Aimin; Awaiye, Kayode; Trabelsi, Fethi

    2013-09-01

    Linear calibration is usually performed using eight to ten calibration concentration levels in regulated LC-MS bioanalysis because a minimum of six are specified in regulatory guidelines. However, we have previously reported that two-concentration linear calibration is as reliable as or even better than using multiple concentrations. The purpose of this research is to compare two-concentration with multiple-concentration linear calibration through retrospective data analysis of multiple bioanalytical projects that were conducted in an independent regulated bioanalytical laboratory. A total of 12 bioanalytical projects were randomly selected: two validations and two studies for each of the three most commonly used types of sample extraction methods (protein precipitation, liquid-liquid extraction, solid-phase extraction). When the existing data were retrospectively linearly regressed using only the lowest and the highest concentration levels, no extra batch failure/QC rejection was observed and the differences in accuracy and precision between the original multi-concentration regression and the new two-concentration linear regression are negligible. Specifically, the differences in overall mean apparent bias (square root of mean individual bias squares) are within the ranges of -0.3% to 0.7% and 0.1-0.7% for the validations and studies, respectively. The differences in mean QC concentrations are within the ranges of -0.6% to 1.8% and -0.8% to 2.5% for the validations and studies, respectively. The differences in %CV are within the ranges of -0.7% to 0.9% and -0.3% to 0.6% for the validations and studies, respectively. The average differences in study sample concentrations are within the range of -0.8% to 2.3%. With two-concentration linear regression, an average of 13% of time and cost could have been saved for each batch together with 53% of saving in the lead-in for each project (the preparation of working standard solutions, spiking, and aliquoting). Furthermore

  10. Determination of total dietary fiber (CODEX definition) by enzymatic-gravimetric method and liquid chromatography: collaborative study.

    Science.gov (United States)

    McCleary, Barry V; DeVries, Jonathan W; Rader, Jeanne I; Cohen, Gerald; Prosky, Leon; Mugford, David C; Champ, Martine; Okuma, Kazuhiro

    2010-01-01

    A method for the determination of total dietary fiber (TDF), as defined by the CODEX Alimentarius, was validated in foods. Based upon the principles of AOAC Official Methods 985.29, 991.43, 2001.03, and 2002.02, the method quantitates high- and low-molecular-weight dietary fiber (HMWDF and LMWDF, respectively). In 2007, McCleary described a method of extended enzymatic digestion at 37 degrees C to simulate human intestinal digestion followed by gravimetric isolation and quantitation of HMWDF and the use of LC to quantitate low-molecular-weight soluble dietary fiber (LMWSDF). The method thus quantitates the complete range of dietary fiber components from resistant starch (by utilizing the digestion conditions of AOAC Method 2002.02) to digestion resistant oligosaccharides (by incorporating the deionization and LC procedures of AOAC Method 2001.03). The method was evaluated through an AOAC collaborative study. Eighteen laboratories participated with 16 laboratories returning valid assay data for 16 test portions (eight blind duplicates) consisting of samples with a range of traditional dietary fiber, resistant starch, and nondigestible oligosaccharides. The dietary fiber content of the eight test pairs ranged from 11.57 to 47.83%. Digestion of samples under the conditions of AOAC Method 2002.02 followed by the isolation and gravimetric procedures of AOAC Methods 985.29 and 991.43 results in quantitation of HMWDF. The filtrate from the quantitation of HMWDF is concentrated, deionized, concentrated again, and analyzed by LC to determine the LMWSDF, i.e., all nondigestible oligosaccharides of degree of polymerization > or =3. TDF is calculated as the sum of HMWDF and LMWSDF. Repeatability standard deviations (Sr) ranged from 0.41 to 1.43, and reproducibility standard deviations (S(R)) ranged from 1.18 to 5.44. These results are comparable to other official dietary fiber methods, and the method is recommended for adoption as Official First Action.

  11. A Guideline to Univariate Statistical Analysis for LC/MS-Based Untargeted Metabolomics-Derived Data

    Directory of Open Access Journals (Sweden)

    Maria Vinaixa

    2012-10-01

    Full Text Available Several metabolomic software programs provide methods for peak picking, retention time alignment and quantification of metabolite features in LC/MS-based metabolomics. Statistical analysis, however, is needed in order to discover those features significantly altered between samples. By comparing the retention time and MS/MS data of a model compound to that from the altered feature of interest in the research sample, metabolites can be then unequivocally identified. This paper reports on a comprehensive overview of a workflow for statistical analysis to rank relevant metabolite features that will be selected for further MS/MS experiments. We focus on univariate data analysis applied in parallel on all detected features. Characteristics and challenges of this analysis are discussed and illustrated using four different real LC/MS untargeted metabolomic datasets. We demonstrate the influence of considering or violating mathematical assumptions on which univariate statistical test rely, using high-dimensional LC/MS datasets. Issues in data analysis such as determination of sample size, analytical variation, assumption of normality and homocedasticity, or correction for multiple testing are discussed and illustrated in the context of our four untargeted LC/MS working examples.

  12. Simultaneous determination of lercanidipine, benazepril and benazeprilat in plasma by LC-MS/MS and its application to a toxicokinetics study.

    Science.gov (United States)

    Chen, Keguang; Zhang, Jing; Liu, Sha; Zhang, Dujuan; Teng, Yanni; Wei, Chunmin; Wang, Benjie; Liu, Xiaoyan; Yuan, Guiyan; Zhang, Rui; Zhao, Wenjing; Guo, Ruichen

    2012-06-15

    We aim to develop a rapid, simple, sensitive and specific LC-MS/MS method for the simultaneous quantification of lercanidipine, benazepril and benazeprilat in plasma. It is performed on the Agilent 6410 LC-MS/MS under the multiple-reaction monitoring (MRM) mode with electrospray ionization. Gliclazide was used as the internal standard (IS). Analytes and IS were extracted from plasma by solid-phase extraction. The reconstituted samples were chromatographed on a Diamond C₁₈(150 mm × 4.6 mm, 5 μm) column. The mobile phase was composed of 0.1% acetic acid-acetonitrile (50:50, v/v), with gradient flow rates: 0.6 mL/min (0-4.55 min); 4.55-4.65 min, 1 mL/min; 1 mL/min (4.65-9.5 min); 9.5-9.6 min, 0.6 mL/min; 0.6 mL/min (9.6-10 min). Method validation demonstrated that the method was of satisfactory specificity, sensitivity, precision and accuracy in linear ranges of 1-2000 ng/mL for lercanidipine, 1-2000 ng/mL for benazepril and 1-1600 ng/mL for benazeprilat, respectively. The precision (RSD%) was better than 15, and the lower limit of quantitation was identifiable and reproducible at 1 ng/mL for the three analytes. The plasma samples were stable after being stored for more than 60 days and after two freeze-thaw cycles (-20 to -25 °C). It is demonstrated that this method was successfully applied to samples from a toxicokinetics study of a compound of lercanidipine and benazepril in beagle dogs. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Bayesian risk-based decision method for model validation under uncertainty

    International Nuclear Information System (INIS)

    Jiang Xiaomo; Mahadevan, Sankaran

    2007-01-01

    This paper develops a decision-making methodology for computational model validation, considering the risk of using the current model, data support for the current model, and cost of acquiring new information to improve the model. A Bayesian decision theory-based method is developed for this purpose, using a likelihood ratio as the validation metric for model assessment. An expected risk or cost function is defined as a function of the decision costs, and the likelihood and prior of each hypothesis. The risk is minimized through correctly assigning experimental data to two decision regions based on the comparison of the likelihood ratio with a decision threshold. A Bayesian validation metric is derived based on the risk minimization criterion. Two types of validation tests are considered: pass/fail tests and system response value measurement tests. The methodology is illustrated for the validation of reliability prediction models in a tension bar and an engine blade subjected to high cycle fatigue. The proposed method can effectively integrate optimal experimental design into model validation to simultaneously reduce the cost and improve the accuracy of reliability model assessment

  14. Spacecraft early design validation using formal methods

    International Nuclear Information System (INIS)

    Bozzano, Marco; Cimatti, Alessandro; Katoen, Joost-Pieter; Katsaros, Panagiotis; Mokos, Konstantinos; Nguyen, Viet Yen; Noll, Thomas; Postma, Bart; Roveri, Marco

    2014-01-01

    The size and complexity of software in spacecraft is increasing exponentially, and this trend complicates its validation within the context of the overall spacecraft system. Current validation methods are labor-intensive as they rely on manual analysis, review and inspection. For future space missions, we developed – with challenging requirements from the European space industry – a novel modeling language and toolset for a (semi-)automated validation approach. Our modeling language is a dialect of AADL and enables engineers to express the system, the software, and their reliability aspects. The COMPASS toolset utilizes state-of-the-art model checking techniques, both qualitative and probabilistic, for the analysis of requirements related to functional correctness, safety, dependability and performance. Several pilot projects have been performed by industry, with two of them having focused on the system-level of a satellite platform in development. Our efforts resulted in a significant advancement of validating spacecraft designs from several perspectives, using a single integrated system model. The associated technology readiness level increased from level 1 (basic concepts and ideas) to early level 4 (laboratory-tested)

  15. Improved profiling of estrogen metabolites by orbitrap LC/MS

    Science.gov (United States)

    Li, Xingnan; Franke, Adrian A.

    2015-01-01

    Estrogen metabolites are important biomarkers to evaluate cancer risks and metabolic diseases. Due to their low physiological levels, a sensitive and accurate method is required, especially for the quantitation of unconjugated forms of endogenous steroids and their metabolites in humans. Here, we evaluated various derivatives of estrogens for improved analysis by orbitrap LC/MS in human serum samples. A new chemical derivatization reagent was applied modifying phenolic steroids to form 1-methylimidazole-2-sulfonyl adducts. The method significantly improves the sensitivity 2–100 fold by full scan MS and targeted selected ion monitoring MS over other derivatization methods including, dansyl, picolinoyl, and pyridine-3-sulfonyl products. PMID:25543003

  16. Method validation for uranium content analysis using a potentiometer T-90

    International Nuclear Information System (INIS)

    Torowati; Ngatijo; Rahmiati

    2016-01-01

    An experimental method validation has been conducted for uranium content analysis using Potentiometer T-90. The method validation experiment was performed in the quality control laboratory of Experiment Fuel Element Installation, PTBBN - BATAN. The objective is to determine the level of precision and accuracy of analytical results for uranium analysis referring to the latest American Standard Test Method (ASTM) of ASTM C1267-11, which is a modified reference method by reducing of reagent consumption by 10% of the amount used by the original method. The ASTM C 1267-11 reference is a new ASTM as a substitute for the older ASTM namely ASTM C799, Vol.12.01, 2003. It is, therefore, necessary to validate the renewed method. The tool used for the analysis of uranium was potentiometer T-90 and the material used was standard uranium oxide powder CRM (Certificate Reference Material). Validation of the method was done by analyzing standard uranium powder by 7 times weighing and 7 times analysis. Analysis results were used to determine the level of accuracy, precision, Relative Standard Deviation (RSD) and Horwitz coefficient Variation and limit detection and quantitation. The average uranium obtained for this method validation is 84.36% with Standard Deviation (SD) of 0.12%, Relative Standard Deviation (RSD) 0.14% and 2/3 Horwitz coefficient Variation (CV Horwitz) 2.05%. The results show that RSD value is smaller than the value of (2/3) CV Horwitz, which means that this method has a high precision. The accuracy value obtained is 0.48%, and since the acceptance limit of high level of accuracy is when the accuracy value is <2.00%, this method is regarded as having a high degree of accuracy [1]. The limit of detection (LOD) and and the limit of quantitation (LOQ) are 0.0145 g/L and 0.0446 g/L respectively. It is concluded that the ASTM C 1267-11 reference method is valid for use. (author)

  17. Simultaneous determination of neonicotinoid insecticides and insect growth regulators residues in honey using LC-MS/MS with anion exchanger-disposable pipette extraction.

    Science.gov (United States)

    Song, Shiming; Zhang, Cuifang; Chen, Zhaojie; He, Fengmei; Wei, Jie; Tan, Huihua; Li, Xuesheng

    2018-07-06

    In this study, we developed an anion exchanger-disposable pipette extraction (DPX) method to detect the residual concentrations of eight neonicotinoid insecticides (dinotefuran, acetamiprid, clothianidin, thiacloprid, imidachloprid, imidaclothiz, nitenpyram, and thiamethoxam) and eight insect growth regulators (IGRs; triflumuron, cyromazine, buprofezin, methoxyfenozide, tebufenozide, chromafenozide, fenoxycarb, and RH 5849) in Chinese honey samples collected from different floral sources and different geographical regions using liquid chromatography tandem mass spectrometry (LC-MS/MS). QAE Sephadex A-25 was used as the anion exchanger in the DPX column for the purification and cleanup of honey samples. Analytes were eluted with a mixture of acetonitrile and 0.1 M HCl, and the elution was subjected to LC analysis. This method was thoroughly validated for its reproducibility, linearity, trueness, and recovery. Satisfactory recovery of pesticides was obtained ranging from 72% to 111% with intraday RSDs (n = 5) of 1%-10%. High linearity (R 2  ≥ 0.9987) was observed for all 16 pesticides. Limits of detection and quantification for all 16 compounds ranged from 0.3 to 3 μg/kg and from 1 to 10 μg/kg, respectively. Pesticide residues (9-113 μg/kg) were found in Chinese honey samples. The anion exchanger-DPX method was effective for removing sugars and retaining target analytes. Moreover, this method was highly reliable and sensitive for detecting neonicotinoids and IGRs in different floral sources of honey and will be applicable to matrixes with high sugar content. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Likelihood ratio data to report the validation of a forensic fingerprint evaluation method

    Directory of Open Access Journals (Sweden)

    Daniel Ramos

    2017-02-01

    Full Text Available Data to which the authors refer to throughout this article are likelihood ratios (LR computed from the comparison of 5–12 minutiae fingermarks with fingerprints. These LRs data are used for the validation of a likelihood ratio (LR method in forensic evidence evaluation. These data present a necessary asset for conducting validation experiments when validating LR methods used in forensic evidence evaluation and set up validation reports. These data can be also used as a baseline for comparing the fingermark evidence in the same minutiae configuration as presented in (D. Meuwly, D. Ramos, R. Haraksim, [1], although the reader should keep in mind that different feature extraction algorithms and different AFIS systems used may produce different LRs values. Moreover, these data may serve as a reproducibility exercise, in order to train the generation of validation reports of forensic methods, according to [1]. Alongside the data, a justification and motivation for the use of methods is given. These methods calculate LRs from the fingerprint/mark data and are subject to a validation procedure. The choice of using real forensic fingerprint in the validation and simulated data in the development is described and justified. Validation criteria are set for the purpose of validation of the LR methods, which are used to calculate the LR values from the data and the validation report. For privacy and data protection reasons, the original fingerprint/mark images cannot be shared. But these images do not constitute the core data for the validation, contrarily to the LRs that are shared.

  19. Testing and Validation of Computational Methods for Mass Spectrometry.

    Science.gov (United States)

    Gatto, Laurent; Hansen, Kasper D; Hoopmann, Michael R; Hermjakob, Henning; Kohlbacher, Oliver; Beyer, Andreas

    2016-03-04

    High-throughput methods based on mass spectrometry (proteomics, metabolomics, lipidomics, etc.) produce a wealth of data that cannot be analyzed without computational methods. The impact of the choice of method on the overall result of a biological study is often underappreciated, but different methods can result in very different biological findings. It is thus essential to evaluate and compare the correctness and relative performance of computational methods. The volume of the data as well as the complexity of the algorithms render unbiased comparisons challenging. This paper discusses some problems and challenges in testing and validation of computational methods. We discuss the different types of data (simulated and experimental validation data) as well as different metrics to compare methods. We also introduce a new public repository for mass spectrometric reference data sets ( http://compms.org/RefData ) that contains a collection of publicly available data sets for performance evaluation for a wide range of different methods.

  20. Dried blood spot analysis of (+) and (-) darunavir enantiomers on immobilized amylose tris-(3, 5-dimethylphenylcarbamate) LC and its application to pharmacokinetics.

    Science.gov (United States)

    Ramisetti, Nageswara Rao; Arnipalli, Manikanta Swamy; Nimmu, Narendra Varma

    2015-12-01

    Dried blood spot analysis is an innovative novel blood sampling technique gaining interest in drug discovery and development processes owing to its inherent advantages over the conventional whole blood, plasma or serum sample collection. The present manuscript describes the development and validation of a highly sensitive and precise method of evaluation of pharmacokinetics of (+) and (-) darunavir enantiomers on rat dried blood spots. The enantiomers on rat dried blood spots were extracted into methanol and separated by LC on a Chiralpak IA column using hexane and ethanol containing 0.1% DEA (75:25, v/v) as a mobile phase at 20°C; both the enantiomers were detected at 266 nm using a photodiode array detector. The method was validated in terms of selectivity, linearity, accuracy, precision and stability as per the US Food and Drug and Administration guidelines. The hematocrit effect on extraction recovery was evaluated and the mean recoveries of (-) and (+) enantiomers of darunavir from dried blood spots were found to be 85.76 and 88.91% respectively. The intra- and inter-day precision and accuracy were 3.1-8.4 and 0.8-4.8% respectively. The developed method was successfully applied to a pharmacokinetic study of (+) and (-) enantiomers of darunavir on rat dried blood spots. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Anti-LC1 autoantibodies in patients with chronic hepatitis C virus infection.

    Science.gov (United States)

    Béland, Kathie; Lapierre, Pascal; Marceau, Gabriel; Alvarez, Fernando

    2004-03-01

    Various autoantibodies have been reported in patients chronically infected by hepatitis C virus. 2% to 10% of theses patients have anti-liver-kidney microsome type 1 (anti-LKM1) autoantibodies. In type 2 autoimmune hepatitis, anti-LKM1 autoantibodies are frequently associated with anti-liver-cytosol type 1 (anti-LC1) autoantibodies. To determine the prevalence of anti-LC1 autoantibodies in a hepatitis C-positive population and characterize their reactivity. 146 patients suffering from liver diseases, of which 99 were chronically infected by hepatitis C virus, were tested by Western blotting and immunoprecipitation to detect and characterize anti-LC1 autoantibodies. 12% of this hepatitis C population had anti-LC1 autoantibodies. LC1 positivity by Western blotting was 30% of LC1+ sera. Epitopes were found throughout the protein but linear epitopes were situated in the 395-541 amino acid region of formiminotransferase cyclodeaminase. Three putative conformational epitopes were identified by phage display. Anti-LC1 autoantibodies are as prevalent as anti-LKM1 autoantibodies in patients infected with hepatitis C virus and their production is not dependent of anti-LKM1 autoantibodies formation. Autoantibody reactivity against the anti-LC1 antigen is different in hepatitis C than in type 2 autoimmune hepatitis. Anti-LC1 autoantibodies can now be regarded as a serological marker of autoimmunity in chronic hepatitis C infection.

  2. Human Factors methods concerning integrated validation of nuclear power plant control rooms

    International Nuclear Information System (INIS)

    Oskarsson, Per-Anders; Johansson, Bjoern J.E.; Gonzalez, Natalia

    2010-02-01

    The frame of reference for this work was existing recommendations and instructions from the NPP area, experiences from the review of the Turbic Validation and experiences from system validations performed at the Swedish Armed Forces, e.g. concerning military control rooms and fighter pilots. These enterprises are characterized by complex systems in extreme environments, often with high risks, where human error can lead to serious consequences. A focus group has been performed with representatives responsible for Human Factors issues from all Swedish NPP:s. The questions that were discussed were, among other things, for whom an integrated validation (IV) is performed and its purpose, what should be included in an IV, the comparison with baseline measures, the design process, the role of SSM, which methods of measurement should be used, and how the methods are affected of changes in the control room. The report brings different questions to discussion concerning the validation process. Supplementary methods of measurement for integrated validation are discussed, e.g. dynamic, psychophysiological, and qualitative methods for identification of problems. Supplementary methods for statistical analysis are presented. The study points out a number of deficiencies in the validation process, e.g. the need of common guidelines for validation and design, criteria for different types of measurements, clarification of the role of SSM, and recommendations for the responsibility of external participants in the validation process. The authors propose 12 measures for taking care of the identified problems

  3. AMP-regulated protein kinase activity in the hearts of mice treated with low- or high-fat diet measured using novel LC-MS method.

    Science.gov (United States)

    Rybakowska, I M; Slominska, E M; Romaszko, P; Olkowicz, M; Kaletha, K; Smolenski, R T

    2015-06-01

    AMP-regulated protein kinase (AMPK) is involved in regulation of energy-generating pathways in response to the metabolic needs in different organs including the heart. The activity of AMPK is mainly controlled by AMP concentration that in turn could be affected by nucleotide metabolic pathways. This study aimed to develop a procedure for measurement of AMPK activity together with nucleotide metabolic enzymes and its application for studies of mice treated with high-fat diet. The method developed was based on analysis of conversion of AMARA peptide to pAMARA by partially purified heart homogenate by liquid chromatography/mass spectrometry (LC/MS). Activities of the enzymes of nucleotide metabolism were evaluated by analysis of conversion of substrates into products by HPLC. The method was applied for analysis of hearts of mice fed 12 weeks with low- (LFD) or high-fat diet (HFD). The optimized method for AMPK activity analysis (measured in presence of AMP) revealed change of activity from 0.089 ± 0.035 pmol/min/mg protein in LFD to 0.024 ± 0.002 in HFD. This coincided with increase of adenosine deaminase (ADA) activity from 0.11 ± 0.02 to 0.19 ± 0.06 nmol/mg tissue/min and decrease of AMP-deaminase (AMPD) activity from 1.26 ± 0.35 to 0.56 ± 0.15 nmol/mg tissue/min for LFD and HFD, respectively. We have proven quality of our LC/MS method for analysis of AMPK activity. We observed decrease in AMPK activity in the heart of mice treated with high-fat diet. However, physiological consequences of this change could be modulated by decrease in AMPD activity.

  4. New validated LC-MS/MS method for the determination of three alkylated adenines in human urine and its application to the monitoring of alkylating agents in cigarette smoke.

    Science.gov (United States)

    Tian, Yongfeng; Hou, Hongwei; Zhang, Xiaotao; Wang, An; Liu, Yong; Hu, Qingyuan

    2014-09-01

    A highly specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous determination of urinary N(3)-methyladenine (N(3)-MeA), N(3)-ethyladenine (N(3)-EtA), and N(3)-(2-hydroxyethyl)adenine (N(3)-HOEtA). Chromatographic separation was achieved on a hydrophilic interaction liquid chromatography column, with a mobile phase gradient prepared from aqueous 10 mM ammonium formate-acetonitrile (5:95 v/v, pH 4.0). Quantification of the analytes was done by multiple reaction monitoring using a triple-quadrupole mass spectrometer in positive-ionization mode. The limits of quantification were 0.13, 0.02, and 0.03 ng/mL for N(3)-MeA, N(3)-EtA, and N(3)-HOEtA, respectively. Intraday and interday variations (relative standard deviations) ranged from 0.6 to 1.3 % and from 3.7 to 7.5 %. The recovery ranges of N(3)-MeA, N(3)-EtA, and N(3)-HOEtA in urine were 80.1-97.3 %, 83.3-90.0 %, and 100.0-110.0 %, respectively. The proposed method was successfully applied to urine samples from 251 volunteers including 193 regular smokers and 58 nonsmokers. The results showed that the levels of urinary N(3)-MeA, N(3)-EtA, and N(3)-HOEtA in smokers were significantly higher than those in nonsmokers. Furthermore, the level of urinary N(3)-MeA in smokers was found to be positively correlated with the level of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (r = 0.48, P alkylating agent exposure.

  5. Identification of hormone esters in injection site in muscle tissues by LC/MS/MS.

    Science.gov (United States)

    Costain, R M; Fesser, A C E; McKenzie, D; Mizuno, M; MacNeil, J D

    2008-12-01

    The detection of hormone abuse for growth promotion in food animal production is a global concern. Initial testing for hormones in Canada was directed at the compounds approved for use in beef cattle, melengestrol acetate, trenbolone acetate and zeranol, and the banned compound diethylstilbestrol (DES). No hormonal growth promoters are approved for use in veal production in Canada. However, instances of use of trenbolone and clenbuterol were detected in Canada in the 1990s. During the development of a new analytical method for testosterone and progesterone, there were reports of suspicious injection sites being found in veal calves. Upon implementation of the method, analysis of investigative samples revealed significant residues of testosterone in some injection sites. To prove that the source of these residues was exogenous, a fully validated method for hormone esters was developed to confirm the presence of exogenous hormones in these injection sites. The QUECHERS model was employed in methods development and resulted in a simple, effective extraction technique that consisted of sample pre-homogenization, liquid/liquid partitioning, extract dilution, filtration and use of LC/MS/MS to provide detection selectivity. The result was an adaptable MS/MS confirmation technique that meets the needs of Canadian regulatory authorities to confirm the misuse of injectable testosterone, and potentially other hormones, in food animal production.

  6. Non-enzymolytic adenosine barcode-mediated dual signal amplification strategy for ultrasensitive protein detection using LC-MS/MS.

    Science.gov (United States)

    Yang, Wen; Li, Tengfei; Shu, Chang; Ji, Shunli; Wang, Lei; Wang, Yan; Li, Duo; Mtalimanja, Michael; Sun, Luning; Ding, Li

    2018-05-10

    A method is described for the determination of proteins with LC-MS/MS enabled by a small molecule (adenosine) barcode and based on a double-recognition sandwich structure. The coagulation protein thrombin was chosen as the model analyte. Magnetic nanoparticles were functionalized with aptamer29 (MNP/apt29) and used to capture thrombin from the samples. MNP/apt29 forms a sandwich with functionalized gold nanoparticles modified with (a) aptamer15 acting as thrombin-recognizing element and (b) a large number of adenosine as mass barcodes. The sandwich formed (MNP/apt29-thrombin-apt15/AuNP/adenosine) can ben magnetically separated from the sample. Mass barcodes are subsequently released from the sandwiched structure for further analysis by adding 11-mercaptoundecanoic acid. Adenosine is then detected by LC-MS/MS as it reflects the level of thrombin with impressively amplified signal. Numerous adenosines introduced into the sandwich proportional to the target concentration further amplify the signal. Under optimized conditions, the response is linearly proportional to the thrombin concentration in the range of 0.02 nM to 10 nM, with a detection limit of 9 fM. The application of this method to the determination of thrombin in spiked plasma samples gave recoveries that ranged from 92.3% to 104.7%. Graphical abstract Schematic representation of a method for the determination of thrombin with LC-MS/MS. The method is based on a double-recognition sandwiched structure. With LC-MS/MS, mass barcodes (adenosine) are detected to quantify thrombin, which amplifies the detection signal impressively.

  7. Validation of calculational methods for nuclear criticality safety - approved 1975

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The American National Standard for Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors, N16.1-1975, states in 4.2.5: In the absence of directly applicable experimental measurements, the limits may be derived from calculations made by a method shown to be valid by comparison with experimental data, provided sufficient allowances are made for uncertainties in the data and in the calculations. There are many methods of calculation which vary widely in basis and form. Each has its place in the broad spectrum of problems encountered in the nuclear criticality safety field; however, the general procedure to be followed in establishing validity is common to all. The standard states the requirements for establishing the validity and area(s) of applicability of any calculational method used in assessing nuclear criticality safety

  8. Simultaneous Determination of Cyclosporine A, Tacrolimus, Sirolimus, and Everolimus in Whole-Blood Samples by LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Mustafa Karapirli

    2012-01-01

    Full Text Available Objectives. Cyclosporine A (CyA, tacrolimus (TRL, sirolimus (SIR, and everolimus (RAD are immunosuppressive drugs frequently used in organ transplantation. Our aim was to confirm a robust sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS method for determination of CyA, TRL, SIR, and RAD in whole-blood samples. Materials and Methods. We used an integrated online solid-phase extraction-LC-MS/MS system and atmospheric pressure ionization tandem mass spectrometry (API-MS/MS in the multiple reaction monitoring (MRM detection mode. CyA, TRL, SIR, and RAD were simultaneously analyzed in whole blood treated with precipitation reagent taken from transplant patients. Results. System performance parameters were suitable for using this method as a high-throughput technique in clinical practice. The high concentration of one analyte in the sample did not affect the concentration of other analytes. Total analytical time was 2.5 min, and retention times of all analytes were shorter than 2 minutes. Conclusion. This LC-MS/MS method can be preferable for therapeutic drug monitoring of these immunosuppressive drugs (CyA, TRL, SRL, and RAD in whole blood. Sample preparation was too short and simple in this method, and it permits robust, rapid, sensitive, selective, and simultaneous determination of these drugs.

  9. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-01-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 μ, The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105 ° C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70-130 μg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  10. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-07-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 µL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 µ. The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105°C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70–130 µg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  11. Rapid analysis of fungal cultures and dried figs for secondary metabolites by LC/TOF-MS

    Energy Technology Data Exchange (ETDEWEB)

    Senyuva, Hamide Z. [Ankara Test and Analysis Laboratory, Scientific and Technological Research Council of Turkey, Ankara 06330 (Turkey)], E-mail: hamide.senyuva@tubitak.gov.tr; Gilbert, John [Central Science Laboratory, Sand Hutton, York YO41 1LZ (United Kingdom); Oztuerkoglu, Sebnem [Ankara Test and Analysis Laboratory, Scientific and Technological Research Council of Turkey, Ankara 06330 (Turkey)

    2008-06-09

    A liquid chromatography-time-of-flight mass spectrometry (LC/TOF-MS) method has been developed for profiling fungal metabolites. The performance of the procedure in terms of mass accuracy, selectivity (specificity) and repeatability was established by spiking aflatoxins, ochratoxins, trichothecenes and other metabolites into blank growth media. After extracting, and carrying out LC/TOF-MS analysis, the standards were correctly identified by searching a specially constructed database of 465 secondary metabolites. To demonstrate the viability of this approach 11 toxigenic and four non-toxigenic fungi from reference collections were grown on various media, for 7-14 days. The method was also applied to two toxigenic fungi, A. flavus (200-138) and A. parasiticus (2999-465) grown on gamma radiation sterilised dried figs, for 7-14 days. The fungal hyphae plus a portion of growth media or portions of dried figs were solvent extracted and analysed by LC/TOF-MS using a rapid resolution microbore LC column. Data processing based on cluster analysis, showed that electrospray ionization (ESI)-TOF-MS could be used to unequivocally identify metabolites in crude extracts. Using the elemental metabolite database, it was demonstrated that from culture collection isolates, anticipated metabolites. The speed and simplicity of the method has meant that levels of these metabolites could be monitored daily in sterilised figs. Over a 14-day period, levels of aflatoxins and kojic acid maximised at 5-6 days, whilst levels of 5-methoxysterigmatocystin remained relatively constant. In addition to the known metabolites expected to be produced by these fungi, roquefortine A, fumagillin, fumigaclavine B, malformins (peptides), aspergillic acid, nigragillin, terrein, terrestric acid and penicillic acid were also identified.

  12. Expedient data mining for nontargeted high-resolution LC-MS profiles of biological samples.

    Science.gov (United States)

    Hnatyshyn, Serhiy; Shipkova, Petia; Sanders, Mark

    2013-05-01

    The application of high-resolution LC-MS metabolomics for drug candidate toxicity screening reflects phenotypic changes of an organism caused by induced chemical interferences. Its success depends not only on the ability to translate the acquired analytical information into biological knowledge, but also on the timely delivery of the results to aid the decision making process in drug discovery and development. Recent improvements in analytical instrumentation have resulted in the ability to acquire extremely information-rich datasets. These new data collection abilities have shifted the bottleneck in the timeline of metabolomic studies to the data analysis step. This paper describes our approach to expedient data analysis of nontargeted high-resolution LC-MS profiles of biological samples. The workflow is illustrated with the example of metabolomics study of time-dependent fasting in male rats. The results from measurement of 220 endogenous metabolites in urine samples illustrate significant biochemical changes induced by fasting. The developed software enables the reporting of relative quantities of annotated components while maintaining practical turnaround times. Each component annotation in the report is validated using both calculated isotopic peaks patterns and experimentally determined retention time data on standards.

  13. Determination of Insecticidal Effect (LC50 and LC90) of Organic Fatty Acids Mixture (C8910+Silicone) Against Aedes aegypti and Aedes albopictus (Diptera: Culicidae).

    Science.gov (United States)

    Dunford, James C; Falconer, Aneika; Leite, Laura N; Wirtz, Robert A; Brogdon, William G

    2016-05-01

    Emerging and re-emerging vector-borne diseases such as chikungunya and dengue and associated Aedes vectors are expanding their historical ranges; thus, there is a need for the development of novel insecticides for use in vector control programs. The mosquito toxicity of a novel insecticide and repellent consisting of medium-chain carbon fatty acids (C8910) was examined. Determination of LC 50 and LC 90 was made against colony-reared Aedes aegypti (L.) and Aedes albopictus (Skuse) using probit analysis on mortality data generated by Centers for Disease Control and Prevention bottle bioassays. Six different concentrations of C8910 + silicone oil yielded an LC 50 of 160.3 µg a.i/bottle (147.6-182.7) and LC 90 of 282.8 (233.2-394.2) in Ae. aegypti; five concentrations yielded an LC 50 of 125.4 (116.1-137.6) and LC 90 of 192.5 (165.0-278.9) in Ae. albopictus. Further development of C8910 and similar compounds could provide vector control specialists novel insecticides for controlling insect disease vectors. Published by Oxford University Press on behalf of Entomological Society of America 2015. This work is written by US Government employees and is in the public domain in the US.

  14. A Greener, Quick and Comprehensive Extraction Approach for LC-MS of Multiple Mycotoxins

    Directory of Open Access Journals (Sweden)

    Andreas Breidbach

    2017-03-01

    Full Text Available In food/feed control, mycotoxin analysis is often still performed “one analyte at a time”. Here a method is presented which aims at making mycotoxin analysis environmentally friendlier through replacing acetonitrile by ethyl acetate and reducing chemical waste production by analyzing four mycotoxins together, forgoing sample extract clean-up, and minimizing solvent consumption. For this, 2 g of test material were suspended in 8 mL water and 16 mL ethyl acetate were added. Extraction was accelerated through sonication for 30 min and subsequent addition of 8 g sodium sulfate. After centrifugation, 500 µL supernatant were spiked with isotopologues, dried down, reconstituted in mobile phase, and measured with LC-MS. The method was validated in-house and through a collaborative study and the performance was fit-for-purpose. Repeatability relative standard deviation (RSDs between 16% at low and 4% at higher contaminations were obtained. The reproducibility RSDs were mostly between 12% and 32%. The trueness of results for T-2 toxin and Zearalenone were not different from 100%, for Deoxynivalenol and HT-2 toxin they were larger than 89%. The extraction was also adapted to a quick screening of Aflatoxin B1 in maize by flow-injection–mass spectrometry. Semi-quantitative results were obtained through standard addition and scan-based ion ratio calculations. The method proved to be a viable greener and quicker alternative to existing methods.

  15. Androgen and androgen metabolite levels in serum and urine of East African chimpanzees (Pan troglodytes schweinfurthii): comparison of EIA and LC-MS analyses.

    Science.gov (United States)

    Preis, Anna; Mugisha, Lawrence; Hauser, Barbara; Weltring, Anja; Deschner, Tobias

    2011-12-01

    The primary male androgen testosterone (T) is often used as an endocrinological marker to investigate androgen-behaviour interactions in males. In chimpanzees and bonobos, studies investigating the relationship between T levels and dominance rank or aggressive behaviour have revealed contradictory results. The immunoassays used in these studies were originally developed for the measurement of steroids in serum. Their application to non-invasively collected samples, however, can lead to methodological problems due to cross-reacting metabolites, which might occur in urine or faeces but not in blood. The overall aim of this study, therefore, is to clarify whether a T enzyme immunoassay (EIA) is an applicable method to monitor testicular function in adult male chimpanzees. To estimate the impact of cross-reacting androgens on the used T EIA, we compared the results of an EIA measurement with a set of androgen metabolite levels measured by LC-MS. In urine from male chimpanzees, cross-reactivities appear to exist mainly with T and its exclusive metabolites, 5α-dihydrotestosterone (5α-DHT) and 5α-androstanediol (androstanediol). Both urinary and serum T levels of male chimpanzees were significantly higher than female T levels when measured with the T EIA, indicating a reliable measurement of testicular androgens and their exclusive metabolites with the used EIA. In urine from female chimpanzees, the comparison between LC-MS and T EIA results indicated a higher impact of cross-reactions with adrenal androgen metabolites. Therefore, the investigation of urinary T levels in female chimpanzees with a T EIA seems to be problematic. Overall our results show that a T EIA can be a reliable method to monitor testicular function in male chimpanzee urine and that LC-MS is a valuable tool for the validation of immunoassays. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Moving beyond Traditional Methods of Survey Validation

    Science.gov (United States)

    Maul, Andrew

    2017-01-01

    In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul wrote that it is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as…

  17. Experimental Peptide Identification Repository (EPIR): an integrated peptide-centric platform for validation and mining of tandem mass spectrometry data

    DEFF Research Database (Denmark)

    Kristensen, Dan Bach; Brønd, Jan Christian; Nielsen, Peter Aagaard

    2004-01-01

    LC MS/MS has become an established technology in proteomic studies, and with the maturation of the technology the bottleneck has shifted from data generation to data validation and mining. To address this bottleneck we developed Experimental Peptide Identification Repository (EPIR), which...... is an integrated software platform for storage, validation, and mining of LC MS/MS-derived peptide evidence. EPIR is a cumulative data repository where precursor ions are linked to peptide assignments and protein associations returned by a search engine (e.g. Mascot, Sequest, or PepSea). Any number of datasets can...

  18. File list: Unc.PSC.20.AllAg.EpiLC [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.PSC.20.AllAg.EpiLC mm9 Unclassified Pluripotent stem cell EpiLC SRX1074910,SRX1...074907 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.PSC.20.AllAg.EpiLC.bed ...

  19. File list: Unc.PSC.50.AllAg.EpiLC [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.PSC.50.AllAg.EpiLC mm9 Unclassified Pluripotent stem cell EpiLC SRX1074910,SRX1...074907 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.PSC.50.AllAg.EpiLC.bed ...

  20. File list: Unc.PSC.10.AllAg.EpiLC [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.PSC.10.AllAg.EpiLC mm9 Unclassified Pluripotent stem cell EpiLC SRX1074910,SRX1...074907 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.PSC.10.AllAg.EpiLC.bed ...

  1. File list: Unc.PSC.05.AllAg.EpiLC [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.PSC.05.AllAg.EpiLC mm9 Unclassified Pluripotent stem cell EpiLC SRX1074910,SRX1...074907 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Unc.PSC.05.AllAg.EpiLC.bed ...

  2. Analyses of marketplace tacrolimus drug product quality: bioactivity, NMR and LC-MS.

    Science.gov (United States)

    Sommers, Cynthia D; Pang, Eric S; Ghasriani, Houman; Berendt, Robert T; Vilker, Vincent L; Keire, David A; Boyne, Michael T

    2013-11-01

    Tacrolimus (FK506) is a potent, narrow therapeutic index, immunosuppressive drug used to avoid organ rejection in patients that have undergone organ transplantation. Recent clinical reports suggested a significant reduction in the tacrolimus concentration/dose ratio in the plasma of liver and kidney recipients when the reference listed drug was substituted with a generic drug. In response to these concerns about switching between tacrolimus from different approved manufacturers during treatment, the FDA initiated purity, potency and quality studies of the innovator and generic tacrolimus products available in the US marketplace. A combination of analytical methods, including mass spectrometry (LC-MS), nuclear magnetic resonance (NMR) and bioactivity assay were developed and validated to assess the quality of tacrolimus. These tests measured the identity, impurities and activity of tacrolimus from active pharmaceutical ingredient (API) sources and with formulated drug product from five different approved manufactures. In addition, some testing was performed on tacrolimus capsules obtained from a non US approved Indian source. The data obtained showed no discernible difference in the impurity profiles and potency between the generic and innovator tacrolimus products. Copyright © 2013. Published by Elsevier B.V.

  3. Validation Process Methods

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, John E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); English, Christine M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gesick, Joshua C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mukkamala, Saikrishna [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2018-01-04

    This report documents the validation process as applied to projects awarded through Funding Opportunity Announcements (FOAs) within the U.S. Department of Energy Bioenergy Technologies Office (DOE-BETO). It describes the procedures used to protect and verify project data, as well as the systematic framework used to evaluate and track performance metrics throughout the life of the project. This report also describes the procedures used to validate the proposed process design, cost data, analysis methodologies, and supporting documentation provided by the recipients.

  4. A simple, rapid and stability indicating validated method for quantification of lamotrigine in human plasma and dry plasma spot using LC-ESI-MS/MS: Application in clinical study.

    Science.gov (United States)

    Namdev, Kuldeep Kumar; Dwivedi, Jaya; Chilkoti, Deepak Chandra; Sharma, Swapnil

    2018-01-01

    Lamotrigine (LTZ) is a phenyltriazine derivative which belongs to anti-epileptic drugs (AEDs) class and prescribed as mono- or adjunctive-therapy in treatment of epilepsy. Therapeutic drug monitoring (TDM) of AEDs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) are suitable alternative to overcome these issues. We developed and validated a new method for quantification of LTZ in human plasma and DPS. The extraction of LTZ from plasma and DPS was performed using liquid-liquid extraction with diethyl ether and an extraction solution composed of diethyl ether- methyl tert-butyl ether- acetone (50:30:20, v/v/v), respectively. Lamotrigine- 13C3, d3 was used as internal standard (ISTD) and the chromatographic separation was achieved on Hypurity Advance C18 column (150×4.6mm, 5μm). Quantitative estimation of LTZ and ISTD was performed on a liquid chromatography tandem mass spectrometer coupled with electrospray ionization interface operated under positive mode of ionization. Calibration curves were linear (r 2 >0.99) over the concentration range of 10-3020ng/mL for both plasma and DPS. Statistical analysis provides insignificant difference between LTZ concentration extracted from plasma and DPS samples. The method is found suitable for application in clinical study and in therapeutic monitoring of LTZ. To the best of our knowledge this is the first report which describing a validated stability indicating assay for quantification of LTZ in dry plasma spot. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. LC-lens array with light field algorithm for 3D biomedical applications

    Science.gov (United States)

    Huang, Yi-Pai; Hsieh, Po-Yuan; Hassanfiroozi, Amir; Martinez, Manuel; Javidi, Bahram; Chu, Chao-Yu; Hsuan, Yun; Chu, Wen-Chun

    2016-03-01

    In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.

  6. Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.

    Science.gov (United States)

    Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C

    2016-01-01

    This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.

  7. A validated RP-HPLC method for the determination of Irinotecan hydrochloride residues for cleaning validation in production area

    Directory of Open Access Journals (Sweden)

    Sunil Reddy

    2013-03-01

    Full Text Available Introduction: cleaning validation is an integral part of current good manufacturing practices in pharmaceutical industry. The main purpose of cleaning validation is to prove the effectiveness and consistency of cleaning in a given pharmaceutical production equipment to prevent cross contamination and adulteration of drug product with other active ingredient. Objective: a rapid, sensitive and specific reverse phase HPLC method was developed and validated for the quantitative determination of irinotecan hydrochloride in cleaning validation swab samples. Method: the method was validated using waters symmetry shield RP-18 (250mm x 4.6mm 5 µm column with isocratic mobile phase containing a mixture of 0.02 M potassium di-hydrogen ortho-phosphate, pH adjusted to 3.5 with ortho-phosphoric acid, methanol and acetonitrile (60:20:20 v/v/v. The flow rate of mobile phase was 1.0 mL/min with column temperature of 25°C and detection wavelength at 220nm. The sample injection volume was 100 µl. Results: the calibration curve was linear over a concentration range from 0.024 to 0.143 µg/mL with a correlation coefficient of 0.997. The intra-day and inter-day precision expressed as relative standard deviation were below 3.2%. The recoveries obtained from stainless steel, PCGI, epoxy, glass and decron cloth surfaces were more than 85% and there was no interference from the cotton swab. The detection limit (DL and quantitation limit (QL were 0.008 and 0.023 µg ml-1, respectively. Conclusion: the developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision and solution stability. The overall procedure can be used as part of a cleaning validation program in pharmaceutical manufacture of irinotecan hydrochloride.

  8. Development and validation of a stability-indicating LC method for the assay of lodenafil carbonate in tablets.

    Science.gov (United States)

    Codevilla, Cristiane Franco; Lemos, Alice Machado; Delgado, Leila Schreiner; Rolim, Clarice Madalena Bueno; Adams, Andréa Inês Horn; Bergold, Ana Maria

    2011-08-01

    A stability-indicating liquid chromatographic method has been developed for the quantitative determination of lodenafil carbonate in tablets. The method employs a Synergi Fusion C18 column (250 × 4.6 mm, i.d., 4 μm particle size), with mobile phase consisting of a mixture of methanol-acetic acid 0.1% pH 4.0 (65:35, v/v) and UV detection at 290 nm, using a photodiode array detector. A linear response (r = 0.9999) was observed in the range of 10-80 μg/mL. The method showed good recoveries (average 100.3%) and also intra and inter-day precision (RSD lodenafil carbonate peak. The method was found to be stability-indicating and due to its simplicity and accuracy can be applied for routine quality control analysis of lodenafil carbonate in tablets.

  9. Development and validation of analytical methods for dietary supplements

    International Nuclear Information System (INIS)

    Sullivan, Darryl; Crowley, Richard

    2006-01-01

    The expanding use of innovative botanical ingredients in dietary supplements and foods has resulted in a flurry of research aimed at the development and validation of analytical methods for accurate measurement of active ingredients. The pressing need for these methods is being met through an expansive collaborative initiative involving industry, government, and analytical organizations. This effort has resulted in the validation of several important assays as well as important advances in the method engineering procedures which have improved the efficiency of the process. The initiative has also allowed researchers to hurdle many of the barricades that have hindered accurate analysis such as the lack of reference standards and comparative data. As the availability for nutraceutical products continues to increase these methods will provide consumers and regulators with the scientific information needed to assure safety and dependable labeling

  10. 利用SPSS软件计算杀虫剂的LC50%Calculatiang the LC50 of insecticides with software SPSS

    Institute of Scientific and Technical Information of China (English)

    贾春生

    2006-01-01

    利用实例和SPSS 130软件上的Probit过程,介绍如何进行LC50计算,并对主要输出结果进行了解释.并通过与其它软件比较,表明应用SPSS软件进行LC50等计算简便、快速、准确.

  11. Quantification of free and total sialic acid excretion by LC-MS/MS

    NARCIS (Netherlands)

    van der Ham, Maria; Prinsen, Berthil H. C. M. T.; Huijmans, Jan G. M.; Abeling, Nicolaas G. G. M.; Dorland, Bert; Berger, Ruud; de Koning, Tom J.; de Sain-van der Velden, Monique G. M.

    2007-01-01

    The main purpose for measuring urinary free sialic acid (FSA) is to diagnose sialic acid (SA) storage diseases. Elevated amounts of conjugated sialic acid (CSA) are observed in several diseases indicating the need to quantify CSA as well. A LC-MS/MS method for quantification of FSA and total sialic

  12. Comparison of various liquid chromatographic methods involving UV and atmospheric pressure chemical ionization mass spectrometric detection for the efficient trace analysis of phenylurea herbicides in various types of water samples.

    Science.gov (United States)

    van der Heeft, E; Dijkman, E; Baumann, R A; Hogendoorn, E A

    2000-05-19

    The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods

  13. Development and validation of an improved LC-MS/MS method for the quantification of desloratadine and its metabolite in human plasma using deutrated desloratadine as internal standard

    Directory of Open Access Journals (Sweden)

    M Saquib Hasnain

    2013-01-01

    Full Text Available Purpose: For the determination of desloratadine (DES and 3-OH desloratadine (3-OHD in human plasma using deutrated desloratadine (DESD5 as internal standard (IS, a novel stability indicating liquid chromatography-tandem mass spectrometric method was developed and validated to support the clinical advancement. Materials and Methods: The solid-phase extraction method used for sample preparation and calibration range was 100-11,000 pg/ml, for which a quadratic regression (1/x 2 was best fitted. The blank plasma was screened and observed free from any endogenous interference. Results: The accuracy (% nominal at low limit of quantification LLOQ level for DES and 3-OHD was 100.4% and 99.9% whereas precision (%CV was 4.6 and 5.1%. They (DES and 3-OHD were stable in human plasma after five freeze-thaw cycles, at room temperature for 23.8 hour, bench top stability for 6.4 hour. Conclusion: This method fulfills all the regulatory requirements for selectivity, sensitivity, precision, accuracy, stability, goodness of fit, and ruggedness of the method for the determination of DES and 3-OHD in human plasma.

  14. Validating the JobFit system functional assessment method

    Energy Technology Data Exchange (ETDEWEB)

    Jenny Legge; Robin Burgess-Limerick

    2007-05-15

    Workplace injuries are costing the Australian coal mining industry and its communities $410 Million a year. This ACARP study aims to meet those demands by developing a safe, reliable and valid pre-employment functional assessment tool. All JobFit System Pre-Employment Functional Assessments (PEFAs) consist of a musculoskeletal screen, balance test, aerobic fitness test and job-specific postural tolerances and material handling tasks. The results of each component are compared to the applicant's job demands and an overall PEFA score between 1 and 4 is given with 1 being the better score. The reliability study and validity study were conducted concurrently. The reliability study examined test-retest, intra-tester and inter-tester reliability of the JobFit System Functional Assessment Method. Overall, good to excellent reliability was found, which was sufficient to be used for comparison with injury data for determining the validity of the assessment. The overall assessment score and material handling tasks had the greatest reliability. The validity study compared the assessment results of 336 records from a Queensland underground and open cut coal mine with their injury records. A predictive relationship was found between PEFA score and the risk of a back/trunk/shoulder injury from manual handling. An association was also found between PEFA score of 1 and increased length of employment. Lower aerobic fitness test results had an inverse relationship with injury rates. The study found that underground workers, regardless of PEFA score, were more likely to have an injury when compared to other departments. No relationship was found between age and risk of injury. These results confirm the validity of the JobFit System Functional Assessment method.

  15. Multidimensional protein fractionation of blood proteins coupled to data-independent nanoLC-MS/MS analysis.

    Science.gov (United States)

    Levin, Yishai; Jaros, Julian A J; Schwarz, Emanuel; Bahn, Sabine

    2010-01-03

    In order to exploit human blood as a source of protein disease biomarkers, robust analytical methods are needed to overcome the inherent molecular complexity of this bio-fluid. We present the coupling of label-free SAX chromatography and IMAC to a data-independent nanoLC-MS/MS (nanoLC-MS(E)) platform for analysis of blood plasma and serum proteins. The methods were evaluated using protein standards added at different concentrations to two groups of samples. The results demonstrate that both techniques enable accurate protein quantitation using low sample volumes and a minimal number of fractions. Combining both methods, 883 unique proteins were identified, of which 423 proteins showed high reproducibility. The two approaches resulted in identification of unique molecular signatures with an overlap of approximately 30%, thus providing complimentary information on sub-proteomes. These methods are potentially useful for systems biology, biomarker discovery, and investigation of phosphoproteins in blood. (c) 2009 Elsevier B.V. All rights reserved.

  16. Content Validity of National Post Marriage Educational Program Using Mixed Methods

    Science.gov (United States)

    MOHAJER RAHBARI, Masoumeh; SHARIATI, Mohammad; KERAMAT, Afsaneh; YUNESIAN, Masoud; ESLAMI, Mohammad; MOUSAVI, Seyed Abbas; MONTAZERI, Ali

    2015-01-01

    Background: Although the validity of content of program is mostly conducted with qualitative methods, this study used both qualitative and quantitative methods for the validation of content of post marriage training program provided for newly married couples. Content validity is a preliminary step of obtaining authorization required to install the program in country's health care system. Methods: This mixed methodological content validation study carried out in four steps with forming three expert panels. Altogether 24 expert panelists were involved in 3 qualitative and quantitative panels; 6 in the first item development one; 12 in the reduction kind, 4 of them were common with the first panel, and 10 executive experts in the last one organized to evaluate psychometric properties of CVR and CVI and Face validity of 57 educational objectives. Results: The raw data of post marriage program had been written by professional experts of Ministry of Health, using qualitative expert panel, the content was more developed by generating 3 topics and refining one topic and its respective content. In the second panel, totally six other objectives were deleted, three for being out of agreement cut of point and three on experts' consensus. The validity of all items was above 0.8 and their content validity indices (0.8–1) were completely appropriate in quantitative assessment. Conclusion: This study provided a good evidence for validation and accreditation of national post marriage program planned for newly married couples in health centers of the country in the near future. PMID:26056672

  17. LC-MS/MS signal suppression effects in the analysis of pesticides in complex environmental matrices.

    Science.gov (United States)

    Choi, B K; Hercules, D M; Gusev, A I

    2001-02-01

    The application of LC separation and mobile phase additives in addressing LC-MS/MS matrix signal suppression effects for the analysis of pesticides in a complex environmental matrix was investigated. It was shown that signal suppression is most significant for analytes eluting early in the LC-MS analysis. Introduction of different buffers (e.g. ammonium formate, ammonium hydroxide, formic acid) into the LC mobile phase was effective in improving signal correlation between the matrix and standard samples. The signal improvement is dependent on buffer concentration as well as LC separation of the matrix components. The application of LC separation alone was not effective in addressing suppression effects when characterizing complex matrix samples. Overloading of the LC column by matrix components was found to significantly contribute to analyte-matrix co-elution and suppression of signal. This signal suppression effect can be efficiently compensated by 2D LC (LC-LC) separation techniques. The effectiveness of buffers and LC separation in improving signal correlation between standard and matrix samples is discussed.

  18. Scope of harmonisation of pharmacopoeial liquid chromatography (LC) methods for diazepam and its related substances

    International Nuclear Information System (INIS)

    Shar, G.Q.; Jatoi, W.B.

    2015-01-01

    Drug analysis is an imperative activity to check the quality of a drug compound. Pharmacopoeial monographs provide important information about the quality of a drug substance. The expected quality of a medicine during period of use is also explained in such monographs. Analytical tools such as spectroscopic and chromatographic methods have been developed for such investigations. We have analysed the purity of a well known anxiolytic drug; diazepam, by using liquid chromatographic (LC) technique. It was noticed that with Zorbax Eclipse XDB - C8 (4.6 x 150 mm, 5 mu m) column and recommended mobile phase comprising acetonitrile - methanol -potassium dihydrogen phosphate (22+34+44 v/v), the desired results obtained were not according the chromatograms provided by European Pharmacopeia (EP), but by using another column (ACE- 5 - C8) (4.6 x 150 mm, 5 ?m), an extra peak of diazepam degradant was obtained, which showed that by using appropriate mobile phase containing CH3CN- CH/sub 3/OH- KH/sub 2/PO/sub 4/ (20+32+48 v/v), the better results can be achieved. The mean retention time for diazepam analysis was 2.9 minutes. (author)

  19. A new liquid chromatography - tandem mass spectrometry method using atmospheric pressure photo ionization for the simultaneous determination of azaarenes and azaarones in Dutch river sediments

    NARCIS (Netherlands)

    Brulik, J.; Simek, Z.; de Voogt, P.

    2013-01-01

    A new method for the analysis of azaarenes and their degradation products (azaarones) was developed, optimized and validated using liquid chromatography coupled with atmospheric pressure photo ionization tandem mass spectrometric detection (LC-APPI/MS/MS). Seventeen compounds including 4 PAHs

  20. Validation of Alternative In Vitro Methods to Animal Testing: Concepts, Challenges, Processes and Tools.

    Science.gov (United States)

    Griesinger, Claudius; Desprez, Bertrand; Coecke, Sandra; Casey, Warren; Zuang, Valérie

    This chapter explores the concepts, processes, tools and challenges relating to the validation of alternative methods for toxicity and safety testing. In general terms, validation is the process of assessing the appropriateness and usefulness of a tool for its intended purpose. Validation is routinely used in various contexts in science, technology, the manufacturing and services sectors. It serves to assess the fitness-for-purpose of devices, systems, software up to entire methodologies. In the area of toxicity testing, validation plays an indispensable role: "alternative approaches" are increasingly replacing animal models as predictive tools and it needs to be demonstrated that these novel methods are fit for purpose. Alternative approaches include in vitro test methods, non-testing approaches such as predictive computer models up to entire testing and assessment strategies composed of method suites, data sources and decision-aiding tools. Data generated with alternative approaches are ultimately used for decision-making on public health and the protection of the environment. It is therefore essential that the underlying methods and methodologies are thoroughly characterised, assessed and transparently documented through validation studies involving impartial actors. Importantly, validation serves as a filter to ensure that only test methods able to produce data that help to address legislative requirements (e.g. EU's REACH legislation) are accepted as official testing tools and, owing to the globalisation of markets, recognised on international level (e.g. through inclusion in OECD test guidelines). Since validation creates a credible and transparent evidence base on test methods, it provides a quality stamp, supporting companies developing and marketing alternative methods and creating considerable business opportunities. Validation of alternative methods is conducted through scientific studies assessing two key hypotheses, reliability and relevance of the

  1. Development of an HPLC fluorescence method for determination of boldine in plasma, bile and urine of rats and identification of its major metabolites by LC-MS/MS.

    Science.gov (United States)

    Hroch, Miloš; Mičuda, Stanislav; Cermanová, Jolana; Chládek, Jaroslav; Tomšík, Pavel

    2013-10-01

    Boldine belongs to the group of aporphine alkaloids isolated from Boldo tree. In contrast with numerous reports on the pharmacological effects of boldine, the data about its pharmacokinetics and biotransformation are scarce. No validated bioanalytical method of sufficient sensitivity has so far been described in the literature which could be used for quantification of boldine in various body fluids collected in pharmacokinetic studies. This work presents, for the first time, the assay for boldine in the plasma, bile and urine of rats. It includes liquid-liquid extraction/back-extraction of boldine, its chromatographic separation and sensitive fluorescence detection. Separation was carried out on a pentafluorophenyl core-shell column (Kinetex PFP, 150×3mm, 2.6μm) in gradient elution mode with solvent system consisting of an acetonitrile-ammonium formate buffer (5mM, pH=3.8). Fluorimetric detection (λEX=320nm, λEM=370nm) was used for quantitative work. Validation according to the EMEA guideline proved the assay LLOQ (0.1μmolL(-1)), linearity over a broad range of 0.1-50μmolL(-1), precision (intra- and inter-day CVs less than 4.5% and 6.1%, respectively) and accuracy (relative errors between -5.8% and 4.8%). In a pilot pharmacokinetic experiment, the concentration-time profiles were described for boldine (single i.v. bolus 50mgkg(-1)) in plasma and bile and cumulative excretion in urine was investigated. The major metabolites identified by means of LC-MS(n) were boldine-O-glucuronide, boldine-O-sulphate and disulphate, boldine-O-glucuronide-O-sulphate and N-demethyl-boldine-O-sulphate. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Investigating the Agent of Temperature into Acute Toxicity (LC50 96h of Edifenphos in Rutilus Frisii Kutum (Kamensky, 1901

    Directory of Open Access Journals (Sweden)

    Saeid Shahbazi Naserabad

    2017-02-01

    Full Text Available Background: Edifenphos, a kind of organophosphate toxins, is used as agricultural fungicides in rice fields. This study was aimed to investigate the effect of temperature on lethal concentration of exposure to edifenphos on Rutilus frisii kutum (Caspian kutum. Methods: The experiment was carried out in static condition and based on instructions of OECD within 10 d under controlled water physicochemical factors. Dissolved oxygen was fixed on 7-7.5 ppm, pH: 7 to 7.5 and hardness: 200 ppm. Fish were acclimatized in 70*40*30 cm aquarium for 10 d before the test. Treated aquariums with concentrations of 0.01, 0.05, 2, 4, 8, 16 ppm of edifenphos with one control group (no toxic concentration, were performed. In order to test the effect of temperature on acute toxicity, three ranges of 15±1, 20±1 and 25±1 ºC were treated and LC1, LC10, LC30, LC50, LC70, LC90 and LC99 were calculated for 24, 48, 72 and 96 h. The study was carried out in Laboratory of Aquaculture and Fisheries, University of Tehran in 2016. Results: LC50 value in 25 ºC was lower than 20 and 15 ºC. LC50 96h edifenphos for Caspian kutum in 15±1, 20±1 and 25±1 ºC was 3.70, 3.61 and 3.26, respectively. Conclusion: Higher temperature increase toxicity rate of edifenphos and the toxin had a positive temperature coefficient on Caspian kutum.

  3. Determination of Modafinil in Tablet Formulation Using Three New Validated Spectrophotometric Methods

    International Nuclear Information System (INIS)

    Basniwal, P.K.; Jain, D.; Basniwal, P.K.

    2014-01-01

    In this study, three new UV spectrophotometric methods viz. linear regression equation (LRE), standard absorptivity (SA) and first order derivative (FOD) method were developed and validated for determination of modafinil in tablet form. The Beer-Lamberts law was obeyed as linear in the range of 10-50 μg/ mL and all the methods were validated for linearity, accuracy, precision and robustness. These methods were successfully applied for assay of modafinil drug content in tablets in the range of 100.20 - 100.42 %, 100.11 - 100.58 % and 100.25 - 100.34 %, respectively with acceptable standard deviation (less than two) for all the methods. The validated spectrophotometric methods may be successfully applied for assay, dissolution studies, bio-equivalence studies as well as routine analysis in pharmaceutical industries. (author)

  4. An Engineering Method of Civil Jet Requirements Validation Based on Requirements Project Principle

    Science.gov (United States)

    Wang, Yue; Gao, Dan; Mao, Xuming

    2018-03-01

    A method of requirements validation is developed and defined to meet the needs of civil jet requirements validation in product development. Based on requirements project principle, this method will not affect the conventional design elements, and can effectively connect the requirements with design. It realizes the modern civil jet development concept, which is “requirement is the origin, design is the basis”. So far, the method has been successfully applied in civil jet aircraft development in China. Taking takeoff field length as an example, the validation process and the validation method of the requirements are detailed introduced in the study, with the hope of providing the experiences to other civil jet product design.

  5. A validated LC-MS/MS method for the quantitative measurement of creatinine as an endogenous biomarker in human plasma.

    Science.gov (United States)

    Zhao, Yue; Liu, Guowen; Angeles, Aida; Christopher, Lisa J; Wang, Zhaoqing; Arnold, Mark E; Shen, Jim X

    2016-10-01

    Creatinine is an endogenous compound generated from creatine by normal muscular metabolism. It is an important indicator of renal function and the serum level is routinely monitored in clinical labs. Results & methodology: Surrogate analyte (d3-creatinine) was used for calibration standard and quality control preparation and the relative instrument response ratio between creatinine and d3-creatinine was used to calculate the endogenous creatinine concentrations. A fit-for-purpose strategy of using a surrogate analyte and authentic matrix was adopted for this validation. The assay was the first human plasma assay using such strategy and was successfully applied to a clinical study to confirm a transient elevation of creatinine observed using an existing clinical assay.

  6. LC/DAD/ESI/MS method for the determination of imidacloprid, thiacloprid, and spinosad in olives and olive oil after field treatment.

    Science.gov (United States)

    Angioni, Alberto; Porcu, Luciano; Pirisi, Filippo

    2011-10-26

    The behavior in the field and the transfer from olives to olive oil during the technological process of imidacloprid, thiacloprid, and spinosad were studied. The extraction method used was effective in extracting the analytes of interest, and no interfering peaks were detected in the chromatogram. The residue levels found in olives after treatment were 0.14, 0.04, and 0.30 mg/kg for imidacloprid, thiacloprid, and spinosad, respectively, far below the maximum residue levels (MRLs) set for these insecticides in EU. At the preharvest interval (PHI), no residue was detected for imidacloprid and thiacloprid, while spinosad showed a residue level of 0.04 mg/kg. The study of the effect of the technological process on pesticide transfer in olive oil showed that these insecticides tend to remain in the olive cake. The LC/DAD/ESI/MS method showed good performance with adequate recoveries ranging from 80 to 119% and good method limits of quantitation (LOQs) and of determination (LODs). No matrix effect was detected.

  7. Fuzzy-logic based strategy for validation of multiplex methods: example with qualitative GMO assays.

    Science.gov (United States)

    Bellocchi, Gianni; Bertholet, Vincent; Hamels, Sandrine; Moens, W; Remacle, José; Van den Eede, Guy

    2010-02-01

    This paper illustrates the advantages that a fuzzy-based aggregation method could bring into the validation of a multiplex method for GMO detection (DualChip GMO kit, Eppendorf). Guidelines for validation of chemical, bio-chemical, pharmaceutical and genetic methods have been developed and ad hoc validation statistics are available and routinely used, for in-house and inter-laboratory testing, and decision-making. Fuzzy logic allows summarising the information obtained by independent validation statistics into one synthetic indicator of overall method performance. The microarray technology, introduced for simultaneous identification of multiple GMOs, poses specific validation issues (patterns of performance for a variety of GMOs at different concentrations). A fuzzy-based indicator for overall evaluation is illustrated in this paper, and applied to validation data for different genetically modified elements. Remarks were drawn on the analytical results. The fuzzy-logic based rules were shown to be applicable to improve interpretation of results and facilitate overall evaluation of the multiplex method.

  8. Trans Ova Genetics, L.C.

    Science.gov (United States)

    The EPA is providing notice of a proposed Administrative Penalty Assessment against Trans Ova Genetics, L.C., a business located at 2938 380th Street Sioux Center, IA 51250, for alleged violations at the Trans Ova Genetics, L.C.’s facility located in 12425

  9. Supercritical CO₂assisted extraction and LC-MS identification of picroside I and picroside II from Picrorhiza kurroa.

    Science.gov (United States)

    Patil, Ajit A; Sachin, Bhusari S; Shinde, Devanand B; Wakte, Pravin S

    2013-02-01

    Picroside I and picroside II have been studied intensively because of their pharmacological actions and clinical applications. Numerous methods have been reported for extracting picroside I and picroside II from Picrorrhiza. kurroa rhizomes. This is the first report of picroside I and picroside II extraction using the supercritical carbon dioxide assisted extraction technique. To develop supercritical carbon dioxide assisted extraction and LC-MS identification of picroside I and picroside II from the Picrorrhiza kurroa Royle rhizomes. Surface response methodology based on 3³ fractional factorial design was used to extract picroside I and picroside II from P. kurroa rhizomes. The effects of various process factors, namely temperature (40-80°C), pressure (25-35 MPa) and co-solvent (methanol) concentration (0-10% v/v) on extraction yield of the two compounds were evaluated. The picroside I and picroside II contents were determined using validated LC-MS methodology. The maximum yield of picroside I (32.502 ± 1.131 mg/g) and picroside II (9.717 ± 0.382 mg/g) was obtained at the 10% v/v co-solvent concentration, 40°C temperature and 30 MPa pressure. The conventional Soxhlet assisted methanol extract of P. kurroa powder resulted in 36.743 ± 1.75 and 11.251 ± 0.54 mg/g yield of picroside I and picroside II, respectively. Variation of concentration and extraction time showed a significant effect on the picroside I and picroside II yield. Supercritical carbon dioxide assisted extraction using methanol as a co-solvent is an efficient and environmentally sustainable method for extracting picroside I and picroside II from P. kurroa rhizomes. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Method development and validation of liquid chromatography-tandem/mass spectrometry for aldosterone in human plasma: Application to drug interaction study of atorvastatin and olmesartan combination

    Directory of Open Access Journals (Sweden)

    Rakesh Das

    2014-01-01

    Full Text Available In the present investigation, a simple and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS method was developed for the quantification of aldosterone (ALD a hormone responsible for blood pressure in human plasma. The developed method was validated and extended for application on human subjects to study drug interaction of atorvastatin (ATSV and olmesartan (OLM on levels of ALD. The ALD in plasma was extracted by liquid-liquid extraction with 5 mL dichloromethane/ethyl ether (60/40% v/v. The chromatographic separation of ALD was carried on Xterra, RP-Column C18 (150 mm× 4.6 mm × 3.5 μm at 30°C followed by four-step gradient program composed of methanol and water. Step 1 started with 35% methanol for first 1 min and changed linearly to 90% in next 1.5 min in Step 2. Step 3 lasted for next 2 min with 90% methanol. The method finally concluded with Step 4 to achieve initial concentration of methanol that is, 35% thus contributing the total method run time of 17.5 min. The flow rate was 0.25 mL/min throughout the process. The developed method was validated for specificity, accuracy, precision, stability, linearity, sensitivity, and recovery. The method was linear and found to be acceptable over the range of 50-800 ng/mL. The method was successfully applied for the drug interaction study of ATSV + OLM in combination against OLM treatment on blood pressure by quantifying changes in levels of ALD in hypertensive patients. The study revealed levels of ALD were significantly higher in ATSV + OLM treatment condition when compared to OLM as single treated condition. This reflects the reason of low effectiveness of ATSV + OLM in combination instead of synergistic activity.

  11. Development and validation of an HPLC/UV/MS method for simultaneous determination of 18 preservatives in grapefruit seed extract.

    Science.gov (United States)

    Ganzera, Markus; Aberham, Anita; Stuppner, Hermann

    2006-05-31

    Grapefruit seed extracts are used in cosmetics, food supplements, and pesticides because of their antimicrobial properties, but suspicions about the true nature of the active compounds arose when synthetic disinfectants such as benzethonium or benzalkonium chloride were found in commercial products. The HPLC method presented herein allows the quality assessment (qualitative and quantitative) of these products for the first time. On the basis of a standard mixture of 18 preservatives most relevant for food and grapefruit products, a method was developed allowing the baseline separation of all compounds within 40 min. Optimum results were obtained with a C-8 stationary phase and a solvent system comprising aqueous trifluoroacetic acid, acetonitrile, and 2-propanol. The assay was fully validated and shown to be sensitive (LOD or = 96.1%), repeatable (sigma(rel) < or = 3.5%), precise (intra-day variation < or = 4.5%, interday variation < or = 4.1%), and rugged. Without any modifications the method could be adopted for LC-MS experiments, where the compounds of interest were directly assignable in positive ESI mode. The quantitative results of several products for ecofarming confirmed previous studies, as seven out of nine specimens were adulterated with preservatives in varying composition. The samples either contained benzethonium chloride (2.5-176.9 mg/mL) or benzalkonium chloride (138.2-236.3 mg/mL), together with smaller amounts of 4-hydroxybenzoic acid esters, benzoic acid, and salicylic acid.

  12. Method development and validation of potent pyrimidine derivative by UV-VIS spectrophotometer.

    Science.gov (United States)

    Chaudhary, Anshu; Singh, Anoop; Verma, Prabhakar Kumar

    2014-12-01

    A rapid and sensitive ultraviolet-visible (UV-VIS) spectroscopic method was developed for the estimation of pyrimidine derivative 6-Bromo-3-(6-(2,6-dichlorophenyl)-2-(morpolinomethylamino) pyrimidine4-yl) -2H-chromen-2-one (BT10M) in bulk form. Pyrimidine derivative was monitored at 275 nm with UV detection, and there is no interference of diluents at 275 nm. The method was found to be linear in the range of 50 to 150 μg/ml. The accuracy and precision were determined and validated statistically. The method was validated as a guideline. The results showed that the proposed method is suitable for the accurate, precise, and rapid determination of pyrimidine derivative. Graphical Abstract Method development and validation of potent pyrimidine derivative by UV spectroscopy.

  13. Application of on-line nanoLC-IT-TOF in the identification of serum β-catenin complex in mice scald model.

    Directory of Open Access Journals (Sweden)

    Cheng-cai Huang

    Full Text Available Severe burn shock remains an unresolved clinical problem with an urgent need to explore novel therapeutic treatments. Intracellular β-catenin, through interaction with other proteins, has been reported to be able to regulate the size of cutaneous wounds. Higher expression of β-catenin is associated with larger sized wounds. However, the identification of serum β-catenin complex is difficult and has been rarely reported. The exploitation of more binding partners can contribute to uncovering the exact mechanisms behind serum β-catenin mediated biological effects. Here, we describe a method that consists of immunoprecipitation, SDS-PAGE, in-gel digestion, and nanoLC coupled to LCMS-IT-TOF for the investigation of serum β-catenin complex in mice scald model. Among selected gel bands obtained from the protein gels, a total of 31 peptides were identified and sequenced with high statistical significance (p<0.01. Three proteins (alpha-2-marcoglobulin, serine protease inhibitor A3K, and serine protease inhibitor A1A were identified and validated with high reliability and high reproducibility. It was inferred that these proteins might interact with serum β-catenin, which could affect the wound healing resulting from burn shock. Our study demonstrated that the on-line coupling of nano-LC with a LCMS-IT-TOF mass spectrometer was capable of sensitive and automated characterization of the serum β-catenin complex in mice scald model.

  14. Development of a Multi-class Steroid Hormone Screening Method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)

    Science.gov (United States)

    Boggs, Ashley S. P.; Bowden, John A.; Galligan, Thomas M.; Guillette, Louis J.; Kucklick, John R.

    2016-01-01

    Monitoring complex endocrine pathways is often limited by indirect measurement or measurement of a single hormone class per analysis. There is a burgeoning need to develop specific direct-detection methods capable of providing simultaneous measurement of biologically relevant concentrations of multiple classes of hormones (estrogens, androgens, progestogens, and corticosteroids). The objectives of this study were to develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for multi-class steroid hormone detection using biologically relevant concentrations, then test limits of detection (LOD) in a high-background matrix by spiking charcoal-stripped fetal bovine serum (FBS) extract. Accuracy was tested with National Institute of Standards and Technology Standard Reference Materials (SRMs) with certified concentrations of cortisol, testosterone, and progesterone. 11-Deoxycorticosterone, 11-deoxycortisol, 17-hydroxypregnenolone, 17-hydroxyprogesterone, adrenosterone, androstenedione, cortisol, corticosterone, dehydroepiandrosterone, dihydrotestosterone, estradiol, estriol, estrone, equilin, pregnenolone, progesterone, and testosterone were also measured using isotopic dilution. Dansyl chloride (DC) derivatization was investigated maintaining the same method to improve and expedite estrogen analysis. Biologically relevant LODs were determined for 15 hormones. DC derivatization improved estrogen response two- to eight-fold, and improved chromatographic separation. All measurements had an accuracy ≤ 14 % difference from certified values (not accounting for uncertainty) and relative standard deviation ≤ 14 %. This method chromatographically separated and quantified biologically relevant concentrations of four hormone classes using highly specific fragmentation patterns and measured certified values of hormones that were previously split into three separate chromatographic methods. PMID:27039201

  15. A long-term validation of the modernised DC-ARC-OES solid-sample method.

    Science.gov (United States)

    Flórián, K; Hassler, J; Förster, O

    2001-12-01

    The validation procedure based on ISO 17025 standard has been used to study and illustrate both the longterm stability of the calibration process of the DC-ARC solid sample spectrometric method and the main validation criteria of the method. In the calculation of the validation characteristics depending on the linearity(calibration), also the fulfilment of predetermining criteria such as normality and homoscedasticity was checked. In order to decide whether there are any trends in the time-variation of the analytical signal or not, also the Neumann test of trend was applied and evaluated. Finally, a comparison with similar validation data of the ETV-ICP-OES method was carried out.

  16. Comparing the Validity of Non-Invasive Methods in Measuring Thoracic Kyphosis and Lumbar Lordosis

    Directory of Open Access Journals (Sweden)

    Mohammad Yousefi

    2012-04-01

    Full Text Available Background: the purpose of this article is to study the validity of each of the non-invasive methods (flexible ruler, spinal mouse, and processing the image versus the one through-Ray radiation (the basic method and comparing them with each other.Materials and Methods: for evaluating the validity of each of these non-invasive methods, the thoracic Kyphosis and lumber Lordosis angle of 20 students of Birjand University (age mean and standard deviation: 26±2, weight: 72±2.5 kg, height: 169±5.5 cm through fours methods of flexible ruler, spinal mouse, and image processing and X-ray.Results: the results indicated that the validity of the methods including flexible ruler, spinal mouse, and image processing in measuring the thoracic Kyphosis and lumber Lordosis angle respectively have an adherence of 0.81, 0.87, 0.73, 0.76, 0.83, 0.89 (p>0.05. As a result, regarding the gained validity against the golden method of X-ray, it could be stated that the three mentioned non-invasive methods have adequate validity. In addition, the one-way analysis of variance test indicated that there existed a meaningful relationship between the three methods of measuring the thoracic Kyphosis and lumber Lordosis, and with respect to the Tukey’s test result, the image processing method is the most precise one.Conclusion as a result, this method could be used along with other non-invasive methods as a valid measuring method.

  17. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  18. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  19. Increased efficacy for in-house validation of real-time PCR GMO detection methods.

    Science.gov (United States)

    Scholtens, I M J; Kok, E J; Hougs, L; Molenaar, B; Thissen, J T N M; van der Voet, H

    2010-03-01

    To improve the efficacy of the in-house validation of GMO detection methods (DNA isolation and real-time PCR, polymerase chain reaction), a study was performed to gain insight in the contribution of the different steps of the GMO detection method to the repeatability and in-house reproducibility. In the present study, 19 methods for (GM) soy, maize canola and potato were validated in-house of which 14 on the basis of an 8-day validation scheme using eight different samples and five on the basis of a more concise validation protocol. In this way, data was obtained with respect to the detection limit, accuracy and precision. Also, decision limits were calculated for declaring non-conformance (>0.9%) with 95% reliability. In order to estimate the contribution of the different steps in the GMO analysis to the total variation variance components were estimated using REML (residual maximum likelihood method). From these components, relative standard deviations for repeatability and reproducibility (RSD(r) and RSD(R)) were calculated. The results showed that not only the PCR reaction but also the factors 'DNA isolation' and 'PCR day' are important factors for the total variance and should therefore be included in the in-house validation. It is proposed to use a statistical model to estimate these factors from a large dataset of initial validations so that for similar GMO methods in the future, only the PCR step needs to be validated. The resulting data are discussed in the light of agreed European criteria for qualified GMO detection methods.

  20. Clinical laboratory verification of thyroglobulin concentrations in the presence of autoantibodies to thyroglobulin: comparison of EIA, radioimmunoassay and LC MS/MS measurements in an Urban Hospital.

    Science.gov (United States)

    Wheeler, Sarah E; Liu, Li; Blair, Harry C; Sivak, Richard; Longo, Nancy; Tischler, Jeffery; Mulvey, Kathryn; Palmer, Octavia M Peck

    2017-12-08

    Thyroglobulin (Tg) measurements assess recurrence in post-thyroidectomy thyroid cancer patients. Tg measurements by enzyme immunoassays (EIA) can be falsely elevated by interference from Tg autoantibodies (TgAb). Radioimmunoassay (RIA) is less susceptible to TgAb interference and has been the standard-of-care test for TgAb positive patients. Recently developed liquid chromatography tandem mass spectrometry (LC-MS/MS) methods may eliminate TgAb interference. We assessed the performance of Tg measurements by EIA, RIA and LC-MS/MS to evaluate TgAb interference differences. We measured TgAb and Tg in 50 plasma samples from 40 patients in whom Tg measurement was part of their routine follow-up and 10 healthy volunteers. Discrepancy between EIA and both LC-MS/MS and RIA was observed at low Tg concentrations (≤ 7.55 ng/mL) in TgAb positive specimens (LC-MS/MS = 1.9 * EIA - 0.03, r = 0.68). RIA and LC-MS/MS Tg measurements in TgAb positive specimens with low Tg concentrations had improved correlation but demonstrated bias (LC MS/MS = 0.6 * RIA - 1.4, r = 0.90). Disagreement between methods may be attributed to LC-MS/MS reported Tg concentrations as undetectable compared to RIA. It seems likely that most discrepant cases are falsely elevated in RIA due to TgAb interference, however, some cases appear below the detection limit of LC-MS/MS; implementation of LC-MS/MS by clinicians will require lower detection limits.

  1. Session-RPE Method for Training Load Monitoring: Validity, Ecological Usefulness, and Influencing Factors

    Directory of Open Access Journals (Sweden)

    Monoem Haddad

    2017-11-01

    Full Text Available Purpose: The aim of this review is to (1 retrieve all data validating the Session-rating of perceived exertion (RPE-method using various criteria, (2 highlight the rationale of this method and its ecological usefulness, and (3 describe factors that can alter RPE and users of this method should take into consideration.Method: Search engines such as SPORTDiscus, PubMed, and Google Scholar databases in the English language between 2001 and 2016 were consulted for the validity and usefulness of the session-RPE method. Studies were considered for further analysis when they used the session-RPE method proposed by Foster et al. in 2001. Participants were athletes of any gender, age, or level of competition. Studies using languages other than English were excluded in the analysis of the validity and reliability of the session-RPE method. Other studies were examined to explain the rationale of the session-RPE method and the origin of RPE.Results: A total of 950 studies cited the Foster et al. study that proposed the session RPE-method. 36 studies have examined the validity and reliability of this proposed method using the modified CR-10.Conclusion: These studies confirmed the validity and good reliability and internal consistency of session-RPE method in several sports and physical activities with men and women of different age categories (children, adolescents, and adults among various expertise levels. This method could be used as “standing alone” method for training load (TL monitoring purposes though some recommend to combine it with other physiological parameters as heart rate.

  2. FAST DETECTION OF ACETYLSALICYLIC ACID BY LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY(LC-MSMS)

    OpenAIRE

    Abusoglu, Sedat; Unlu, Ali; Sivrikaya, Abdullah

    2018-01-01

    ObjectivesAcetylsalicylic acid (ASA) is themost widely used as an analgesic, anti-inflammatory and antipyretic drug, andalso used to inhibit cyclooxygenase dependent platelet aggregation.   The aimof this study was to develop a simple, fast and accurate tandem mass method fordetermination and quantification of ASA.  MethodsChromatographic seperation was performedusing an Shimadzu LC-20-AD (Kyoto, Japan) coupledwith a ABSCIEX API 3200 triple quadrupole massspectromete...

  3. Validity in Mixed Methods Research in Education: The Application of Habermas' Critical Theory

    Science.gov (United States)

    Long, Haiying

    2017-01-01

    Mixed methods approach has developed into the third methodological movement in educational research. Validity in mixed methods research as an important issue, however, has not been examined as extensively as that of quantitative and qualitative research. Additionally, the previous discussions of validity in mixed methods research focus on research…

  4. A compact, all solid-state LC high voltage generator.

    Science.gov (United States)

    Fan, Xuliang; Liu, Jinliang

    2013-06-01

    LC generator is widely applied in the field of high voltage generation technology. A compact and all solid-state LC high voltage generator based on saturable pulse transformer is proposed in this paper. First, working principle of the generator is presented. Theoretical analysis and circuit simulation are used to verify the design of the generator. Experimental studies of the proposed LC generator with two-stage main energy storage capacitors are carried out. And the results show that the proposed LC generator operates as expected. When the isolation inductance is 27 μH, the output voltage is 1.9 times larger than the charging voltage on single capacitor. The multiplication of voltages is achieved. On the condition that the primary energy storage capacitor is charged to 857 V, the output voltage of the generator can reach to 59.5 kV. The step-up ratio is nearly 69. When self breakdown gas gap switch is used as main switch, the rise time of the voltage pulse on load resistor is 8.7 ns. It means that the series-wound inductance in the discharging circuit is very small in this system. This generator can be employed in two different applications.

  5. Development of a universal metabolome-standard method for long-term LC-MS metabolome profiling and its application for bladder cancer urine-metabolite-biomarker discovery.

    Science.gov (United States)

    Peng, Jun; Chen, Yi-Ting; Chen, Chien-Lun; Li, Liang

    2014-07-01

    Large-scale metabolomics study requires a quantitative method to generate metabolome data over an extended period with high technical reproducibility. We report a universal metabolome-standard (UMS) method, in conjunction with chemical isotope labeling liquid chromatography-mass spectrometry (LC-MS), to provide long-term analytical reproducibility and facilitate metabolome comparison among different data sets. In this method, UMS of a specific type of sample labeled by an isotope reagent is prepared a priori. The UMS is spiked into any individual samples labeled by another form of the isotope reagent in a metabolomics study. The resultant mixture is analyzed by LC-MS to provide relative quantification of the individual sample metabolome to UMS. UMS is independent of a study undertaking as well as the time of analysis and useful for profiling the same type of samples in multiple studies. In this work, the UMS method was developed and applied for a urine metabolomics study of bladder cancer. UMS of human urine was prepared by (13)C2-dansyl labeling of a pooled sample from 20 healthy individuals. This method was first used to profile the discovery samples to generate a list of putative biomarkers potentially useful for bladder cancer detection and then used to analyze the verification samples about one year later. Within the discovery sample set, three-month technical reproducibility was examined using a quality control sample and found a mean CV of 13.9% and median CV of 9.4% for all the quantified metabolites. Statistical analysis of the urine metabolome data showed a clear separation between the bladder cancer group and the control group from the discovery samples, which was confirmed by the verification samples. Receiver operating characteristic (ROC) test showed that the area under the curve (AUC) was 0.956 in the discovery data set and 0.935 in the verification data set. These results demonstrated the utility of the UMS method for long-term metabolomics and

  6. Laboratory diagnostic methods, system of quality and validation

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2005-01-01

    Full Text Available It is known that laboratory investigations secure safe and reliable results that provide a final confirmation of the quality of work. Ideas, planning, knowledge, skills, experience, and environment, along with good laboratory practice, quality control and reliability of quality, make the area of biological investigations very complex. In recent years, quality control, including the control of work in the laboratory, is based on international standards and is used at that level. The implementation of widely recognized international standards, such as the International Standard ISO/IEC 17025 (1 and the implementing of the quality system series ISO/IEC 9000 (2 have become the imperative on the grounds of which laboratories have a formal, visible and corresponding system of quality. The diagnostic methods that are used must constantly yield results which identify the animal as positive or negative, and the precise status of the animal is determined with a predefined degree of statistical significance. Methods applied on a selected population reduce the risk of obtaining falsely positive or falsely negative results. A condition for this are well conceived and documented methods, with the application of the corresponding reagents, and work with professional and skilled staff. This process requires also a consistent implementation of the most rigorous experimental plans, epidemiological and statistical data and estimations, with constant monitoring of the validity of the applied methods. Such an approach is necessary in order to cut down the number of misconceptions and accidental mistakes, for a referent population of animals on which the validity of a method is tested. Once a valid method is included in daily routine investigations, it is necessary to apply constant monitoring for the purpose of internal quality control, in order adequately to evaluate its reproducibility and reliability. Consequently, it is necessary at least twice yearly to conduct

  7. Molecular cloning and expression analyses of porcine MAP1LC3A in the granulosa cells of normal and miniature pig

    Directory of Open Access Journals (Sweden)

    Kim Sang H

    2013-02-01

    Full Text Available Abstract Background The members of the microtubule-associated protein 1 light chain (MAP1LC family, especially those of the LC3 family (MAP1LC3A, B, C, are known to induce autophagy upon localization onto the autophagosomal membrane. In this regard, LC3 can be utilized as a marker for the formation of autophagosomes during the process of autophagy. The aims of this study are to clone porcine MAP1LC3A, and analyze the pattern of its expression in the ovarian tissues of normal and miniature pig ovary in an attempt to understand the distinct mode of apoptosis between two strains. Methods Rapid amplification of cDNA ends (RACE were used to obtain the 5′ and 3′ ends of the porcine MAP1LC3A full length cDNA. Reverse-transcriptase-PCR (RT-PCR, real-time PCR, and western blot analysis were performed to examine the expression of porcine MAP1LC3A. The localization of MAP1LC3A in the ovary was determined by In situ Hybridization and Immunohistochemical staining. Results We cloned the full-length cDNA of porcine MAP1LC3A and identified an open reading frame of 980 bp encoding 121 amino acids. Based on its homology to known mammalian proteins (98% this novel cDNA was designated as porcine MAP1LC3A and registered to the GenBank (Accession No. GU272221. We compared the expression of MAP1LC3A in the Graafian follicles of normal and miniature pigs by in situ hybridization at day 15 of the estrus cycle. While normal pigs showed a stronger expression of MAP1LC3A mRNA than miniature pigs in the theca cell area, the expression was lower in the granulosa cells. Immunofluorescence analysis of the MAP1LC3A fusion reporter protein showed the subcellular localization of porcine MAP1LC3A and ATG5 as a punctate pattern in the cytoplasm of porcine granulosa cells under stress conditions. In addition, the expressions of MAP1LC3A and ATG5 were higher in normal pigs than in miniature pigs both in the presence and absence of rapamycin. Conclusions The newly cloned porcine

  8. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    OpenAIRE

    2011-01-01

    Abstract In the present work, a liquid chromatography- high resolution mass spectrometry method was developed for the screening in meat of a wide range of antibiotics used in veterinary medicine. Full scan mode under high resolution mass spectral conditions using LTQ-Orbitrap mass spectrometer with resolving power 60.000 FWHM was applied for analysis of the samples. Samples were prepared using two extractions protocols prior to LC-MS analysis. The scope of the method focuses on the...

  9. Comparison of LC-ESI-MS and GC-MS for the Analysis of a Synthetic Tabun Sample

    National Research Council Canada - National Science Library

    D'Agostino, Paul

    2003-01-01

    Packed capillary LC-ESI-MS and capillary column GC-MS were compared for the analysis of a synthetic tabun sample as each method has advantages for the analysis of samples containing chemical warfare...

  10. Validated RP-HPLC Method for Quantification of Phenolic ...

    African Journals Online (AJOL)

    Purpose: To evaluate the total phenolic content and antioxidant potential of the methanol extracts of aerial parts and roots of Thymus sipyleus Boiss and also to determine some phenolic compounds using a newly developed and validated reversed phase high performance liquid chromatography (RP-HPLC) method.

  11. Development and Validation of a Bioanalytical Method for Direct ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a user-friendly spiked plasma method for the extraction of diclofenac potassium that reduces the number of treatments with plasma sample, in order to minimize human error. Method: Instead of solvent evaporation technique, the spiked plasma sample was modified with H2SO4 and NaCl, ...

  12. Quantification of pharmaceutical peptides in human plasma by LC-ICP-MS sulfur detection

    DEFF Research Database (Denmark)

    Møller, Laura Hyrup; Macherius, André; Hansen, Thomas Hesselhøj

    2016-01-01

    A method for quantification of a pharmaceutical peptide in human plasma was developed using gradient elution LC-ICP-MS. A membrane desolvation (MD) system was applied to remove organic solvents from the eluent prior to the detection as SO+ in the dynamic reaction cell (DRC) of the ICP-DRC-MS inst......A method for quantification of a pharmaceutical peptide in human plasma was developed using gradient elution LC-ICP-MS. A membrane desolvation (MD) system was applied to remove organic solvents from the eluent prior to the detection as SO+ in the dynamic reaction cell (DRC) of the ICP......-DRC-MS instrument and subsequent quantification by post-column isotope dilution (IDA). Plasma proteins were precipitated prior to analysis. Analytical figures of merit including linearity, precision, LOD, LOQ and accuracy were considered satisfactory for analysis of plasma samples. The selectivity of the developed...... method was demonstrated for five pharmaceutically relevant peptides: desmopressin, penetratin, substance P, PTH (1-34) and insulin. Preliminary experiments on an ICP-MS/MS system using oxygen to reduce the effect of organic solvents were also performed to compare sensitivity. The results of the study...

  13. Formic acid hydrolysis/liquid chromatography isotope dilution mass spectrometry: An accurate method for large DNA quantification.

    Science.gov (United States)

    Shibayama, Sachie; Fujii, Shin-Ichiro; Inagaki, Kazumi; Yamazaki, Taichi; Takatsu, Akiko

    2016-10-14

    Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) with formic acid hydrolysis was established for the accurate quantification of λDNA. The over-decomposition of nucleobases in formic acid hydrolysis was restricted by optimizing the reaction temperature and the reaction time, and accurately corrected by using deoxynucleotides (dNMPs) and isotope-labeled dNMPs as the calibrator and the internal standard, respectively. The present method could quantify λDNA with an expanded uncertainty of 4.6% using 10fmol of λDNA. The analytical results obtained with the present method were validated by comparing with the results of phosphate-base quantification by inductively coupled plasma-mass spectrometry (ICP-MS). The results showed good agreement with each other. We conclude that the formic acid hydrolysis/LC-IDMS method can quantify λDNA accurately and is promising as the primary method for the certification of DNA as reference material. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Rationale and methods of the European Food Consumption Validation (EFCOVAL) Project

    NARCIS (Netherlands)

    Boer, de E.J.; Slimani, N.; Boeing, H.; Feinberg, M.; Leclerq, C.; Trolle, E.; Amiano, P.; Andersen, L.F.; Freisling, H.; Geelen, A.; Harttig, U.; Huybrechts, I.; Kaic-Rak, A.; Lafay, L.; Lillegaard, I.T.L.; Ruprich, J.; Vries, de J.H.M.; Ocke, M.C.

    2011-01-01

    Background/Objectives: The overall objective of the European Food Consumption Validation (EFCOVAL) Project was to further develop and validate a trans-European food consumption method to be used for the evaluation of the intake of foods, nutrients and potentially hazardous chemicals within the

  15. A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.

    Science.gov (United States)

    Yang, Harry; Zhang, Jianchun

    2015-01-01

    The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current

  16. A guideline for the validation of likelihood ratio methods used for forensic evidence evaluation.

    Science.gov (United States)

    Meuwly, Didier; Ramos, Daniel; Haraksim, Rudolf

    2017-07-01

    This Guideline proposes a protocol for the validation of forensic evaluation methods at the source level, using the Likelihood Ratio framework as defined within the Bayes' inference model. In the context of the inference of identity of source, the Likelihood Ratio is used to evaluate the strength of the evidence for a trace specimen, e.g. a fingermark, and a reference specimen, e.g. a fingerprint, to originate from common or different sources. Some theoretical aspects of probabilities necessary for this Guideline were discussed prior to its elaboration, which started after a workshop of forensic researchers and practitioners involved in this topic. In the workshop, the following questions were addressed: "which aspects of a forensic evaluation scenario need to be validated?", "what is the role of the LR as part of a decision process?" and "how to deal with uncertainty in the LR calculation?". The questions: "what to validate?" focuses on the validation methods and criteria and "how to validate?" deals with the implementation of the validation protocol. Answers to these questions were deemed necessary with several objectives. First, concepts typical for validation standards [1], such as performance characteristics, performance metrics and validation criteria, will be adapted or applied by analogy to the LR framework. Second, a validation strategy will be defined. Third, validation methods will be described. Finally, a validation protocol and an example of validation report will be proposed, which can be applied to the forensic fields developing and validating LR methods for the evaluation of the strength of evidence at source level under the following propositions. Copyright © 2016. Published by Elsevier B.V.

  17. Matrix-calibrated LC-MS/MS quantitation and sensory evaluation of oak Ellagitannins and their transformation products in red wines.

    Science.gov (United States)

    Stark, Timo; Wollmann, Nadine; Wenker, Kerstin; Lösch, Sofie; Glabasnia, Arne; Hofmann, Thomas

    2010-05-26

    Aimed at investigating the concentrations and taste contribution of the oak-derived ellagitannins castalagin and vescalagin as well as their transformation products acutissimin A/B, epiacutissimin A/B, and beta-1-O-ethylvescalagin in red wine, a highly sensitive and accurate quantification method was developed on the basis of LC-MS/MS-MRM analysis with matrix calibration. Method validation showed good recovery rates ranging from 102.4 +/- 5.9% (vescalagin) to 113.7 +/- 15.2% (epiacutissimin A). In oak-matured wines, castalagin was found as the predominant ellagitannin, followed by beta-1-O-ethylvescalagin, whereas the flavano-C-ellagitannins (epi)acutissimin A/B were present in significantly lower amounts. In contrast to the high threshold concentration levels (600-1000 micromol/L) and the puckering astringent orosensation induced by flavan-3-ols, all of the ellagitannin derivatives were found to induce a smooth and velvety astringent oral sensation at rather low threshold concentrations ranging from 0.9 to 2.8 micromol/L. Dose/activity considerations demonstrated that, among all the ellagitannins investigated, castalagin exclusively exceeded its threshold concentration in various oak-matured wine samples.

  18. Methods for Geometric Data Validation of 3d City Models

    Science.gov (United States)

    Wagner, D.; Alam, N.; Wewetzer, M.; Pries, M.; Coors, V.

    2015-12-01

    Geometric quality of 3D city models is crucial for data analysis and simulation tasks, which are part of modern applications of the data (e.g. potential heating energy consumption of city quarters, solar potential, etc.). Geometric quality in these contexts is however a different concept as it is for 2D maps. In the latter case, aspects such as positional or temporal accuracy and correctness represent typical quality metrics of the data. They are defined in ISO 19157 and should be mentioned as part of the metadata. 3D data has a far wider range of aspects which influence their quality, plus the idea of quality itself is application dependent. Thus, concepts for definition of quality are needed, including methods to validate these definitions. Quality on this sense means internal validation and detection of inconsistent or wrong geometry according to a predefined set of rules. A useful starting point would be to have correct geometry in accordance with ISO 19107. A valid solid should consist of planar faces which touch their neighbours exclusively in defined corner points and edges. No gaps between them are allowed, and the whole feature must be 2-manifold. In this paper, we present methods to validate common geometric requirements for building geometry. Different checks based on several algorithms have been implemented to validate a set of rules derived from the solid definition mentioned above (e.g. water tightness of the solid or planarity of its polygons), as they were developed for the software tool CityDoctor. The method of each check is specified, with a special focus on the discussion of tolerance values where they are necessary. The checks include polygon level checks to validate the correctness of each polygon, i.e. closeness of the bounding linear ring and planarity. On the solid level, which is only validated if the polygons have passed validation, correct polygon orientation is checked, after self-intersections outside of defined corner points and edges

  19. Content validity of methods to assess malnutrition in cancer patients: a systematic review

    NARCIS (Netherlands)

    Sealy, Martine; Nijholt, Willemke; Stuiver, M.M.; van der Berg, M.M.; Ottery, Faith D.; van der Schans, Cees; Roodenburg, Jan L N; Jager-Wittenaar, Harriët

    Content validity of methods to assess malnutrition in cancer patients: A systematic review Rationale: Inadequate operationalisation of the multidimensial concept of malnutrition may result in inadequate evaluation of nutritional status. In this review we aimed to assess content validity of methods

  20. Development and Validation of a Liquid Chromatographic Method ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous determination of six human immunodeficiency virus (HIV) protease inhibitors, indinavir, saquinavir, ritonavir, amprenavir, nelfinavir and lopinavir, was developed and validated. Optimal separation was achieved on a PLRP-S 100 Å, 250 x 4.6 mm I.D. column maintained ...

  1. File list: InP.PSC.50.AllAg.EpiLC [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.PSC.50.AllAg.EpiLC mm9 Input control Pluripotent stem cell EpiLC SRX823839,SRX5...5,SRX823838,SRX823831,SRX823826,SRX590324 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.PSC.50.AllAg.EpiLC.bed ...

  2. Quantitative determination and sampling of azathioprine residues for cleaning validation in production area.

    Science.gov (United States)

    Fazio, Tatiana Tatit; Singh, Anil Kumar; Kedor-Hackmann, Erika Rosa Maria; Santoro, Maria Inês Rocha Miritello

    2007-03-12

    Cleaning validation is an integral part of current good manufacturing practices in any pharmaceutical industry. Nowadays, azathioprine and several other pharmacologically potent pharmaceuticals are manufactured in same production area. Carefully designed cleaning validation and its evaluation can ensure that residues of azathioprine will not carry over and cross contaminate the subsequent product. The aim of this study was to validate simple analytical method for verification of residual azathioprine in equipments used in the production area and to confirm efficiency of cleaning procedure. The HPLC method was validated on a LC system using Nova-Pak C18 (3.9 mm x 150 mm, 4 microm) and methanol-water-acetic acid (20:80:1, v/v/v) as mobile phase at a flow rate of 1.0 mL min(-1). UV detection was made at 280 nm. The calibration curve was linear over a concentration range from 2.0 to 22.0 microg mL(-1) with a correlation coefficient of 0.9998. The detection limit (DL) and quantitation limit (QL) were 0.09 and 0.29 microg mL(-1), respectively. The intra-day and inter-day precision expressed as relative standard deviation (R.S.D.) were below 2.0%. The mean recovery of method was 99.19%. The mean extraction-recovery from manufacturing equipments was 83.5%. The developed UV spectrophotometric method could only be used as limit method to qualify or reject cleaning procedure in production area. Nevertheless, the simplicity of spectrophotometric method makes it useful for routine analysis of azathioprine residues on cleaned surface and as an alternative to proposed HPLC method.

  3. Passive Reactor Compensated Cascaded H-Bridge Multilevel LC-StatCom

    DEFF Research Database (Denmark)

    Farivar, Glen; Townsend, Christopher David; Hredzak, Branislav

    2017-01-01

    The cascaded H-bridge (CHB) low-capacitance StatCom (LC-StatCom) has a limited operating area in the inductive region compared to a conventional StatCom's V–I characteristic. This limitation for operation in the inductive region is considered to be the biggest disadvantage of CHB LC-StatCom. In t...

  4. Analysis of cocoa flavanols and procyanidins (DP 1-10) in cocoa-containing ingredients and products by rapid resolution liquid chromatography: single-laboratory validation.

    Science.gov (United States)

    Machonis, Philip R; Jones, Matthew A; Kwik-Uribe, Catherine

    2014-01-01

    Recently, a multilaboratory validation (MLV) of AOAC Official Method 2012.24 for the determination of cocoa flavanols and procyanidins (CF-CP) in cocoa-based ingredients and products determined that the method was robust, reliable, and transferrable. Due to the complexity of the CF-CP molecules, this method required a run time exceeding 1 h to achieve acceptable separations. To address this issue, a rapid resolution normal phase LC method was developed, and a single-laboratory validation (SLV) study conducted. Flavanols and procyanidins with a degree of polymerization (DP) up to 10 were eluted in 15 min using a binary gradient applied to a diol stationary phase, detected using fluorescence detection, and reported as a total sum of DP 1-10. Quantification was achieved using (-)-epicatechin-based relative response factors for DP 2-10. Spike recovery samples and seven different types of cocoa-based samples were analyzed to evaluate the accuracy, precision, LOD, LOQ, and linearity of the method. The within-day precision of the reported content for the samples was 1.15-5.08%, and overall precision was 3.97-13.61%. Spike-recovery experiments demonstrated recoveries of over 98%. The results of this SLV were compared to those previously obtained in the MLV and found to be consistent. The translation to rapid resolution LC allowed for an 80% reduction in analysis time and solvent usage, while retaining the accuracy and reliability of the original method. The savings in both cost and time of this rapid method make it well-suited for routine laboratory use.

  5. Empirical Performance of Cross-Validation With Oracle Methods in a Genomics Context.

    Science.gov (United States)

    Martinez, Josue G; Carroll, Raymond J; Müller, Samuel; Sampson, Joshua N; Chatterjee, Nilanjan

    2011-11-01

    When employing model selection methods with oracle properties such as the smoothly clipped absolute deviation (SCAD) and the Adaptive Lasso, it is typical to estimate the smoothing parameter by m-fold cross-validation, for example, m = 10. In problems where the true regression function is sparse and the signals large, such cross-validation typically works well. However, in regression modeling of genomic studies involving Single Nucleotide Polymorphisms (SNP), the true regression functions, while thought to be sparse, do not have large signals. We demonstrate empirically that in such problems, the number of selected variables using SCAD and the Adaptive Lasso, with 10-fold cross-validation, is a random variable that has considerable and surprising variation. Similar remarks apply to non-oracle methods such as the Lasso. Our study strongly questions the suitability of performing only a single run of m-fold cross-validation with any oracle method, and not just the SCAD and Adaptive Lasso.

  6. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  7. New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.

    Science.gov (United States)

    Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio

    2007-12-01

    Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.

  8. Determination of vitamin C in foods: current state of method validation.

    Science.gov (United States)

    Spínola, Vítor; Llorent-Martínez, Eulogio J; Castilho, Paula C

    2014-11-21

    Vitamin C is one of the most important vitamins, so reliable information about its content in foodstuffs is a concern to both consumers and quality control agencies. However, the heterogeneity of food matrixes and the potential degradation of this vitamin during its analysis create enormous challenges. This review addresses the development and validation of high-performance liquid chromatography methods for vitamin C analysis in food commodities, during the period 2000-2014. The main characteristics of vitamin C are mentioned, along with the strategies adopted by most authors during sample preparation (freezing and acidification) to avoid vitamin oxidation. After that, the advantages and handicaps of different analytical methods are discussed. Finally, the main aspects concerning method validation for vitamin C analysis are critically discussed. Parameters such as selectivity, linearity, limit of quantification, and accuracy were studied by most authors. Recovery experiments during accuracy evaluation were in general satisfactory, with usual values between 81 and 109%. However, few methods considered vitamin C stability during the analytical process, and the study of the precision was not always clear or complete. Potential future improvements regarding proper method validation are indicated to conclude this review. Copyright © 2014. Published by Elsevier B.V.

  9. Multiple testing issues in discriminating compound-related peaks and chromatograms from high frequency noise, spikes and solvent-based noise in LC-MS data sets

    NARCIS (Netherlands)

    Nyangoma, Stephen O.; van Kampen, Antoine A. H. C.; Reijmers, Theo H.; Govorukhina, Natalia I.; van der Zee, Ate G. J.; Billingham, Lucinda J.; Bischoff, Rainer; Jansen, Ritsert C.

    2007-01-01

    Liquid Chromatography - Mass Spectrometry (LC-MS) is a powerful method for sensitive detection and quantification of proteins and peptides in complex biological fluids like serum. LC-MS produces complex data sets, consisting of some hundreds of millions of data points per sample at a resolution of

  10. New 2LC-Y DC-DC converter topologies for high-voltage/low-current renewable applications

    DEFF Research Database (Denmark)

    Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar; Maroti, Pandav Kiran

    2017-01-01

    (2LC-LVD, 2LC-2LVD, 2LC-2LCVD and 2LC-2LCmVD) converters are presented in this treatise which offer an effective solution for renewable applications requiring a very high voltage conversion ratio such as a Photovoltaic Multilevel Inverter (PV-MLI) system, hybrid electrical drives and automotive...

  11. Full validation of a method for the determination of drugs of abuse in non-mineralized dental biofilm using liquid chromatography-tandem mass spectrometry and application to postmortem samples.

    Science.gov (United States)

    Henkel, Kerstin; Altenburger, Markus J; Auwärter, Volker; Neukamm, Merja A

    2018-01-01

    Alternative matrices play a major role in postmortem forensic toxicology, especially if common matrices (like body fluids or hair) are not available. Incorporation of illicit and medicinal drugs into non-mineralized dental biofilm (plaque) seems likely but has not been investigated so far. Analysis of plaque could therefore extend the spectrum of potentially used matrices in postmortem toxicology. For this reason, a rapid, simple and sensitive method for the extraction, determination and quantification of ten drugs of abuse from plaque using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and fully validated. Amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), 3,4-methylenedioxyamphetamine (MDA), cocaine, benzoylecgonine, morphine, codeine and 6-acetylmorphine were extracted from 2mg of dried and powdered plaque via ultrasonication with acetonitrile. The extracts were analyzed on a triple-quadrupole linear ion trap mass spectrometer in scheduled multiple reaction monitoring mode (sMRM). The method was fully validated and proved accurate, precise, selective and specific with satisfactory linearity within the calibrated ranges. The lower limit of quantification was 10-15pgmg -1 for all compounds except for MDA (100pgmg -1 ) and amphetamine (200pgmg -1 ). The method has been successfully applied to three authentic postmortem samples with known drug history. Amphetamine, MDMA, cocaine, benzoylecgonine, morphine and codeine could be detected in these cases in concentrations ranging from 18pgmg -1 for cocaine to 1400pgmg -1 for amphetamine. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous determination of sulfonamides, trimethoprim and dapsone in muscle, egg, milk and honey.

    Science.gov (United States)

    Varenina, Ivana; Bilandžić, Nina; Kolanović, Božica Solomun; Božić, Đurđica; Sedak, Marija; Đokić, Maja; Varga, Ines

    2016-01-01

    A quantitative multi-residue method that includes 13 sulfonamides, trimethoprim and dapsone was developed and validated according to Commission Decision 2002/657/EC for muscle, milk egg and honey samples. For all matrices, the same extraction procedure was used. Samples were extracted with an acetone/dichloromethane mixture and cleaned up on aromatic sulfonic acid (SO3H) SPE cartridges. After elution and concentration steps, analytes were identified and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Data were acquired according to the multiple reaction-monitoring approach (MRM) and analytes were quantified both by the isotope dilution and the matrix-matched approaches calculating the response factors for the scanned product ions. The developed method shows good linearity, specificity, precision (repeatability and within-laboratory reproducibility), and trueness. Estimated CCβ for sulfonamides ranged between 5.6 and 8.2 µg kg(-1) for eggs, between 11.1 and 69.9 µg kg(-1) for milk, between 64.7 and 87.9 µg kg(-1) for muscle, and between 2.7 and 5.3 µg kg(-1) for honey. CCβ values for dapsone were 3.1, 0.6, 0.7 and 1.5 µg kg(-1) and for trimethoprim were 3.1, 6.7, 81.7 and 3.0 µg kg(-1) calculated for eggs, milk, muscle and honey, respectively. Recovery for all matrices was in the range from 89.1% and 109.7%. In matrix effect testing, no significant deviations were found between different samples of muscle and milk; however, a matrix effect was observed when testing different types of honey. The validation results demonstrate that the method is suitable for routine veterinary drug analysis and confirmation of suspect samples.

  13. [Data validation methods and discussion on Chinese materia medica resource survey].

    Science.gov (United States)

    Zhang, Yue; Ma, Wei-Feng; Zhang, Xiao-Bo; Zhu, Shou-Dong; Guo, Lan-Ping; Wang, Xing-Xing

    2013-07-01

    From the beginning of the fourth national survey of the Chinese materia medica resources, there were 22 provinces have conducted pilots. The survey teams have reported immense data, it put forward the very high request to the database system construction. In order to ensure the quality, it is necessary to check and validate the data in database system. Data validation is important methods to ensure the validity, integrity and accuracy of census data. This paper comprehensively introduce the data validation system of the fourth national survey of the Chinese materia medica resources database system, and further improve the design idea and programs of data validation. The purpose of this study is to promote the survey work smoothly.

  14. VALUE - Validating and Integrating Downscaling Methods for Climate Change Research

    Science.gov (United States)

    Maraun, Douglas; Widmann, Martin; Benestad, Rasmus; Kotlarski, Sven; Huth, Radan; Hertig, Elke; Wibig, Joanna; Gutierrez, Jose

    2013-04-01

    Our understanding of global climate change is mainly based on General Circulation Models (GCMs) with a relatively coarse resolution. Since climate change impacts are mainly experienced on regional scales, high-resolution climate change scenarios need to be derived from GCM simulations by downscaling. Several projects have been carried out over the last years to validate the performance of statistical and dynamical downscaling, yet several aspects have not been systematically addressed: variability on sub-daily, decadal and longer time-scales, extreme events, spatial variability and inter-variable relationships. Different downscaling approaches such as dynamical downscaling, statistical downscaling and bias correction approaches have not been systematically compared. Furthermore, collaboration between different communities, in particular regional climate modellers, statistical downscalers and statisticians has been limited. To address these gaps, the EU Cooperation in Science and Technology (COST) action VALUE (www.value-cost.eu) has been brought into life. VALUE is a research network with participants from currently 23 European countries running from 2012 to 2015. Its main aim is to systematically validate and develop downscaling methods for climate change research in order to improve regional climate change scenarios for use in climate impact studies. Inspired by the co-design idea of the international research initiative "future earth", stakeholders of climate change information have been involved in the definition of research questions to be addressed and are actively participating in the network. The key idea of VALUE is to identify the relevant weather and climate characteristics required as input for a wide range of impact models and to define an open framework to systematically validate these characteristics. Based on a range of benchmark data sets, in principle every downscaling method can be validated and compared with competing methods. The results of

  15. Pre-validation methods for developing a patient reported outcome instrument

    Directory of Open Access Journals (Sweden)

    Castillo Mayret M

    2011-08-01

    Full Text Available Abstract Background Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology. Methods The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ. The five steps are: 1 Generation of a pool of items; 2 Item de-duplication (three phases; 3 Item reduction (two phases; 4 Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF; and 5 qualitative exploration of the target populations' views of the new instrument and the items it contains. Results The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items. Conclusions This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped

  16. Verification of propofol sulfate as a further human propofol metabolite using LC-ESI-QQQ-MS and LC-ESI-QTOF-MS analysis.

    Science.gov (United States)

    Maas, Alexandra; Maier, Christoph; Michel-Lauter, Beate; Broecker, Sebastian; Madea, Burkhard; Hess, Cornelius

    2017-03-01

    Propofol (2,6-diisopropylphenol) is a water-insoluble, intravenous anesthetic that is widely used for the induction and maintenance of anesthesia as well as for endoscopic and pediatric sedation. After admission, propofol undergoes extensive hepatic and extrahepatic metabolism, including direct conjugation to propofol glucuronide and hydroxylation to 2,6-diisopropyl-1,4-quinol. The latter substance subsequently undergoes phase II metabolism, resulting in the formation of further metabolites (1quinolglucuronide, 4quinolglucuronide and 4quinol-sulfate). Further minor phase I propofol metabolites (2-(ω-propanol)-6-isopropylphenol and 2-(ω-propanol)-6-isopropyl-1,4-quinol)) are also described. Due to its chemical structure with the phenolic hydroxyl group, propofol is also an appropriate substrate for sulfation by sulfotransferases. The existence of propofol sulfate was investigated by liquid chromatography electrospray ionization triple quadrupole mass spectrometry (LCESIQQQ-MS) and liquid chromatography electrospray ionization quadrupole time-of-flight mass spectrometry (LCESI-QTOF-MS). A propofol sulfate reference standard was used for identification and method development, yielding a precursor at m/z 257 (deprotonated propofol sulfate) and product ions at m/z 177 (deprotonated propofol) and m/z 80 ([SO3]-). Propofol sulfate - a further phase II metabolite of propofol - was verified in urine samples by LC-ESI-QQQ-MS and LC-ESI-QTOF-MS. Analyses of urine samples from five volunteers collected before and after propofol-induced sedation verified the presence of propofol sulfate in urine following propofol administration, whereas ascertained concentrations of this metabolite were significantly lower compared with detected propofol glucuronide concentrations. The existence of propofol sulfate as a further phase II propofol metabolite in humans could be verified by two different detection techniques (LCESIQQQ-MS and LC-ESI-QTOFMS) on the basis of a propofol sulfate

  17. Detection and identification of dyes in blue writing inks by LC-DAD-orbitrap MS.

    Science.gov (United States)

    Sun, Qiran; Luo, Yiwen; Yang, Xu; Xiang, Ping; Shen, Min

    2016-04-01

    In the field of forensic questioned document examination, to identify dyes detected in inks not only provides a solid foundation for ink discrimination in forged contents identification, but also facilitates the investigation of ink origin or the study regarding ink dating. To detect and identify potential acid and basic dyes in blue writing inks, a liquid chromatography-diode array detection-Orbitrap mass spectrometry (LC-DAD-Orbitrap MS) method was established. Three sulfonic acid dyes (Acid blue 1, Acid blue 9 and Acid red 52) and six triphenylmethane basic dyes (Ethyl violet, Crystal violet, Methyl violet 2B, Basic blue 7, Victoria blue B and Victoria blue R) were employed as reference dyes for method development. Determination of the nine dyes was validated to evaluate the instrument performance, and it turned out to be sensitive and stable enough for quantification. The method was then applied in the screening analysis of ten blue roller ball pen inks and twenty blue ballpoint pen inks. As a result, including TPR (a de-methylated product of Crystal violet), ten known dyes and four unknown dyes were detected in the inks. The latter were further identified as a de-methylated product of Victoria blue B, Acid blue 104, Acid violet 49 and Acid blue 90, through analyzing their characteristic precursor and product ions acquired by Orbitrap MS with good mass accuracy. The results showed that the established method is capable of detecting and identifying potential dyes in blue writing inks. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Impurities in biogas - validation of analytical methods for siloxanes; Foeroreningar i biogas - validering av analysmetodik foer siloxaner

    Energy Technology Data Exchange (ETDEWEB)

    Arrhenius, Karine; Magnusson, Bertil; Sahlin, Eskil [SP Technical Research Institute of Sweden, Boraas (Sweden)

    2011-11-15

    Biogas produced from digester or landfill contains impurities which can be harmful for component that will be in contact with the biogas during its utilization. Among these, the siloxanes are often mentioned. During combustion, siloxanes are converted to silicon dioxide which accumulates on the heated surfaces in combustion equipment. Silicon dioxide is a solid compound and will remain in the engine and cause damages. Consequently, it is necessary to develop methods for the accurate determination of these compounds in biogases. In the first part of this report, a method for analysis of siloxanes in biogases was validated. The sampling was performed directly at the plant by drawing a small volume of biogas onto an adsorbent tube under a short period of time. These tubes were subsequently sent to the laboratory for analysis. The purpose of method validation is to demonstrate that the established method is fit for the purpose. This means that the method, as used by the laboratory generating the data, will provide data that meets a set of criteria concerning precision and accuracy. At the end, the uncertainty of the method was calculated. In the second part of this report, the validated method was applied to real samples collected in waste water treatment plants, co-digestion plants and plants digesting other wastes (agriculture waste). Results are presented at the end of this report. As expected, the biogases from waste water treatment plants contained largely higher concentrations of siloxanes than biogases from co-digestion plants and plants digesting agriculture wastes. The concentration of siloxanes in upgraded biogas regardless of which feedstock was digested and which upgrading technique was used was low.

  19. Determination of vandetanib in human plasma and cerebrospinal fluid by liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS).

    Science.gov (United States)

    Bai, Feng; Johnson, Jennifer; Wang, Fan; Yang, Lei; Broniscer, Alberto; Stewart, Clinton F

    2011-09-01

    A sensitive and precise LC-ESI-MS/MS method for the determination of vandetanib (ZD6474) in human plasma and cerebrospinal fluid (CSF) using [(13)C,d(3)]-ZD6474 as an internal standard (ISTD) was developed and validated. Sample preparation consisted of a simple liquid-liquid extraction with tert-butyl methyl ether containing 0.1% or 0.5% ammonium hydroxide. ZD6474 and ISTD were separated on a Kinetex C18 column (2.6 μm, 50 mm × 2.1 mm) at ambient temperature with an isocratic mobile phase (acetonitrile/10mM ammonium formate=50/50, v/v, at pH 5.0) delivered at 0.11 mL/min. The retention time of both compounds was at 1.60 min in a runtime of three min. Detection was achieved by an API-3200 LC-MS/MS system, monitoring m/z 475.1/112.1 and m/z 479.1/116.2 for vandetanib and ISTD, respectively. The method was linear in the range of 0.25-50 ng/mL (R(2) ≥ 0.990) for the CSF curve and from 1.0 to 3000 ng/mL (R(2) ≥ 0.992) for the plasma curve. The mean recovery for vandetanib was 80%. Within-day and between-day precisions were ≤ 8.8% and ≤ 5.9% for CSF and plasma, respectively. Within-day and between-day accuracies ranged from 95.0 to 98.5% for CSF, and from 104.0 to 108.5% for plasma. Analysis of plasma from six different sources showed no matrix effect for vandetanib (MF=0.98, %CV ≤ 4.97, n=6). This method was successfully applied to the analysis of pharmacokinetic samples from children with brain tumors treated with oral vandetanib. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Studies on separation and pharmacokinetics of m-nisoldipine enantiomers in beagle dog plasma by LC/MS/MS.

    Science.gov (United States)

    Li, Min; Yuan, Lin; Li, Xiuqing; Zhi, Xuran; Sheng, Ning; Zhang, Lantong

    2013-11-01

    A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method was developed and validated for the separation and determination of m-nisoldipine enantiomers in beagle dog plasma. Samples were pretreated by a single-step protein precipitation with acetonitrile. After m-nisoldipine racemic administration to beagle dogs, samples of m-nisoldipine enantiomers in beagle dog plasma were separated and determined on a ULTRON ES-OVM column (150 × 4.6 mm, 5 μm) at 20°C with a mobile phase consisted of methanol-acetonitrile-ammonium acetate (pH 7.0; 2mM) (15:15:70, v/v/v) at a flow rate of 0.8 mL/min. Chromatograms were monitored at 237 nm, and the API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM) scan mode using ElectroSpray ionization (ESI) source. The good linearity (rs=0.9958 and rr=0.9983) were found in the range 0.25-20 ng/mL. The lower limit of quantification (LLOQ) obtained was 0.25 ng/mL (n=6). All the validation data, such as accuracy, precision, intra-day and inter-day repeatability, were within the required limits. The method was successfully applied to separation and pharmacokinetics of m-nisoldipine enantiomers in beagle dog plasma. The result of statistics analysis shows that there are no significant differences between R-(-)-m-nisoldipine and S-(+)-m-nisoldipine (p>0.05). The study provides necessary evidences for the research and new drug development of m-nisoldipine enantiomers. Copyright © 2013. Published by Elsevier B.V.