WorldWideScience

Sample records for vaginal mesh erosion

  1. Mesh erosion after abdominal sacrocolpopexy.

    Science.gov (United States)

    Kohli, N; Walsh, P M; Roat, T W; Karram, M M

    1998-12-01

    To report our experience with erosion of permanent suture or mesh material after abdominal sacrocolpopexy. A retrospective chart review was performed to identify patients who underwent sacrocolpopexy by the same surgeon over 8 years. Demographic data, operative notes, hospital records, and office charts were reviewed after sacrocolpopexy. Patients with erosion of either suture or mesh were treated initially with conservative therapy followed by surgical intervention as required. Fifty-seven patients underwent sacrocolpopexy using synthetic mesh during the study period. The mean (range) postoperative follow-up was 19.9 (1.3-50) months. Seven patients (12%) had erosions after abdominal sacrocolpopexy with two suture erosions and five mesh erosions. Patients with suture erosion were asymptomatic compared with patients with mesh erosion, who presented with vaginal bleeding or discharge. The mean (+/-standard deviation) time to erosion was 14.0+/-7.7 (range 4-24) months. Both patients with suture erosion were treated conservatively with estrogen cream. All five patients with mesh erosion required transvaginal removal of the mesh. Mesh erosion can follow abdominal sacrocolpopexy over a long time, and usually presents as vaginal bleeding or discharge. Although patients with suture erosion can be managed successfully with conservative treatment, patients with mesh erosion require surgical intervention. Transvaginal removal of the mesh with vaginal advancement appears to be an effective treatment in patients failing conservative management.

  2. Transrectal Mesh Erosion Requiring Bowel Resection.

    Science.gov (United States)

    Kemp, Marta Maria; Slim, Karem; Rabischong, Benoît; Bourdel, Nicolas; Canis, Michel; Botchorishvili, Revaz

    To report a case of a transrectal mesh erosion as complication of laparoscopic promontofixation with mesh repair, necessitating bowel resection and subsequent surgical interventions. Sacrocolpopexy has become a standard procedure for vaginal vault prolapse [1], and the laparoscopic approach has gained popularity owing to more rapid recovery and less morbidity [2,3]. Mesh erosion is a well-known complication of surgical treatment for prolapse as reported in several negative evaluations, including a report from the US Food and Drug Administration in 2011 [4]. Mesh complications are more common after surgeries via the vaginal approach [5]; nonetheless, the incidence of vaginal mesh erosion after laparoscopic procedures is as high as 9% [6]. The incidence of transrectal mesh exposure after laparoscopic ventral rectopexy is roughly 1% [7]. The diagnosis may be delayed because of its rarity and variable presentation. In addition, polyester meshes, such as the mesh used in this case, carry a higher risk of exposure [8]. A 57-year-old woman experiencing genital prolapse, with the cervix classified as +3 according to the Pelvic Organ Prolapse Quantification system, underwent laparoscopic standard sacrocolpopexy using polyester mesh. Subtotal hysterectomy and bilateral adnexectomy were performed concomitantly. A 3-year follow-up consultation demonstrated no signs or symptoms of erosion of any type. At 7 years after the surgery, however, the patient presented with rectal discharge, diagnosed as infectious rectocolitis with the isolation of Clostridium difficile. She underwent a total of 5 repair surgeries in a period of 4 months, including transrectal resection of exposed mesh, laparoscopic ablation of mesh with digestive resection, exploratory laparoscopy with abscess drainage, and exploratory laparoscopy with ablation of residual mesh and transverse colostomy. She recovered well after the last intervention, exhibiting no signs of vaginal or rectal fistula and no recurrence

  3. Vaginal mucosal flap as a sling preservation for the treatment of vaginal exposure of mesh.

    Science.gov (United States)

    Kim, Sea Young; Park, Jong Yeon; Kim, Han Kwon; Park, Chang Hoo; Kim, Sung Jin; Sung, Gi Teck; Park, Chang Myon

    2010-06-01

    Tension-free vaginal tape (TVT) procedures are used for the treatment of stress urinary incontinence in women. The procedures with synthetic materials can have a risk of vaginal erosion. We experienced transobturator suburethral sling (TOT) tape-induced vaginal erosion and report the efficacy of a vaginal mucosal covering technique. A total of 560 female patients diagnosed with stress urinary incontinence underwent TOT procedures at our hospital between January 2005 and August 2009. All patients succeeded in follow-ups, among which 8 patients (mean age: 50.5 years) presented with vaginal exposure of the mesh. A vaginal mucosal covering technique was performed under local anesthesia after administration of antibiotics and vaginal wound dressings for 3-4 days. Seven of the 8 patients complained of persistent vaginal discharge postoperatively. Two of the 8 patients complained of dyspareunia of their male partners. The one remaining patient was otherwise asymptomatic, but mesh erosion was discovered at the routine follow-up visit. Six of the 8 patients showed complete mucosal covering of the mesh after the operation (mean follow-up period: 16 moths). Vaginal mucosal erosion recurred in 2 patients, and the mesh was then partially removed. One patient had recurrent stress urinary incontinence. Vaginal mucosal covering as a sling preservation with continued patient continence may be a feasible and effective option for the treatment of vaginal exposure of mesh after TOT tape procedures.

  4. Robotic removal of eroded vaginal mesh into the bladder.

    Science.gov (United States)

    Macedo, Francisco Igor B; O'Connor, Jeffrey; Mittal, Vijay K; Hurley, Patrick

    2013-11-01

    Vaginal mesh erosion into the bladder after midurethral sling procedure or cystocele repair is uncommon, with only a few cases having been reported in the literature. The ideal surgical management is still controversial. Current options for removal of eroded mesh include: endoscopic, transvaginal or abdominal (either open or laparoscopic) approaches. We, herein, present the first case of robotic removal of a large eroded vaginal mesh into the bladder and discuss potential benefits and limitations of the technique. © 2013 The Japanese Urological Association.

  5. Intravesical midurethral sling mesh erosion secondary to transvaginal mesh reconstructive surgery

    Directory of Open Access Journals (Sweden)

    Sukanda Bin Jaili

    2015-05-01

    Conclusion: Repeated vaginal reconstructive surgery may jeopardize a primary mesh or sling, and pose a high risk of mesh erosion, which may be delayed for several years. Removal of the mesh erosion and bladder repair are feasible pervaginally with good outcome.

  6. Vaginal native tissue repair versus transvaginal mesh repair for apical prolapse: how utilizing different methods of analysis affects the estimated trade-off between reoperation for mesh exposure/erosion and reoperation for recurrent prolapse.

    Science.gov (United States)

    Dieter, Alexis A; Willis-Gray, Marcella G; Weidner, Alison C; Visco, Anthony G; Myers, Evan R

    2015-05-01

    Informed decision-making about optimal surgical repair of apical prolapse with vaginal native tissue (NT) versus transvaginal mesh (TVM) requires understanding the balance between the potential "harm" of mesh-related complications and the potential "benefit" of reducing prolapse recurrence. Synthesis of data from observational studies is required and the current literature shows that the average follow-up for NT repair is significantly longer than for TVM repair. We examined this harm/benefit balance. We hypothesized that using different methods of analysis to incorporate follow-up time would affect the balance of outcomes. We used a Markov state transition model to estimate the cumulative 24-month probabilities of reoperation for mesh exposure/erosion or for recurrent prolapse after either NT or TVM repair. We used four different analytic approaches to estimate probability distributions ranging from simple pooled proportions to a random effects meta-analysis using study-specific events per patient-time. As variability in follow-up time was accounted for better, the balance of outcomes became more uncertain. For TVM repair, the incremental ratio of number of operations for mesh exposure/erosion per single reoperation for recurrent prolapse prevented increased progressively from 1.4 to over 100 with more rigorous analysis methods. The most rigorous analysis showed a 70% probability that TVM would result in more operations for recurrent prolapse repair than NT. Based on the best available evidence, there is considerable uncertainty about the harm/benefit trade-off between NT and TVM for apical prolapse repair. Future studies should incorporate time-to-event analyses, with greater standardization of reporting, in order to better inform decision-making.

  7. Reconstructive laparoscopic prolapse surgery to avoid mesh erosions

    Directory of Open Access Journals (Sweden)

    Devassy, Rajesh

    2013-09-01

    Full Text Available Introduction: The objective of the study is to examine the efficacy of the purely laparoscopic reconstructive management of cystocele and rectocele with mesh, to avoid the risk of erosion by the graft material, a well known complication in vaginal mesh surgery. Material and methods: We performed a prospective, single-case, non-randomized study in 325 patients who received laparoscopic reconstructive management of pelvic organe prolaps with mesh. The study was conducted between January 2004 and December 2012 in a private clinic in India. The most common prolapse symptoms were reducible vaginal lump, urinary stress incontinence, constipation and flatus incontinence, sexual dysfunction and dypareunia. The degree e of the prolaps was staged according to POPQ system. The approach was purely laparoscopic and involved the use of polypropylene (Prolene or polyurethane with activated regenerated cellulose coating (Parietex mesh. Results: The mean age was 55 (30–80 years and the most of the patients were multiparous (272/325. The patients received a plastic correction of the rectocele only (138 cases, a cystocele and rectocele (187 cases with mesh. 132 patients had a concomitant total hysterectomy; in 2 cases a laparoscopic supracervical hysterectomy was performed and 190 patients had a laparoscopic colposuspension. The mean operation time was 82.2 (60–210 minutes. The mean follow up was 3.4 (3–5 years. Urinary retention developed in 1 case, which required a new laparoscopical intervention. Bladder injury, observed in the same case was in one session closed with absorbable suture. There were four recurrences of the rectocele, receiving a posterior vaginal colporrhaphy. Erosions of the mesh were not reported or documented. Conclusion: The pure laparoscopic reconstructive management of the cystocele and rectocele with mesh seems to be a safe and effective surgical procedure potentially avoiding the risk of mesh erosions.

  8. Delayed vaginal and urethral mesh exposure: 10 years after TVT surgery.

    Science.gov (United States)

    Khanuengkitkong, Siwatchaya; Lo, Tsia-Shu; Dass, Anil Krishna

    2013-03-01

    Delayed mesh exposure after tension-free vaginal tape (TVT) procedure is rare. We report a case of mesh exposure into the vagina and urethra that developed 10 years after TVT surgery. A 58-year-old postmenopausal woman presented with mixed urinary incontinence. She was investigated, and her stress urinary incontinence was cured with a TVT procedure 10 years ago. She was then scheduled follow-up annually. Two years postsurgery, a granulation tissue was observed and excised at the vaginal incision site. Vaginal examination 10 years postsurgery showed vaginal mesh erosion 0.5 cm from urethral meatus. Cystoscopy revealed concomitant urethral erosion at the posterior urethral wall. Mesh excision was performed, and urethra and vagina were repaired in layers. Postoperative recovery was uneventful. This finding shows that, although rare, complications can occur even after 10 years of TVT surgery.

  9. Vaginal Approaches Using Synthetic Mesh to Treat Pelvic Organ Prolapse

    OpenAIRE

    Moon, Jei Won; Chae, Hee Dong

    2016-01-01

    Pelvic organ prolapse (POP) is a very common condition in elderly women. In women with POP, a sacrocolpopexy or a vaginal hysterectomy with anterior and posterior colporrhaphy has long been considered as the gold standard of treatment. However, in recent decades, the tendency to use a vaginal approach with mesh for POP surgery has been increasing. A vaginal approach using mesh has many advantages, such as its being less invasive than an abdominal approach and easier to do than a laparoscopic ...

  10. Vaginal Mucosal Flap as a Sling Preservation for the Treatment of Vaginal Exposure of Mesh

    OpenAIRE

    Kim, Sea Young; Park, Jong Yeon; Kim, Han Kwon; Park, Chang Hoo; Kim, Sung Jin; Sung, Gi Teck; Park, Chang Myon

    2010-01-01

    Purpose Tension-free vaginal tape (TVT) procedures are used for the treatment of stress urinary incontinence in women. The procedures with synthetic materials can have a risk of vaginal erosion. We experienced transobturator suburethral sling (TOT) tape-induced vaginal erosion and report the efficacy of a vaginal mucosal covering technique. Materials and Methods A total of 560 female patients diagnosed with stress urinary incontinence underwent TOT procedures at our hospital between January 2...

  11. The effects of vaginal prolapse surgery using synthetic mesh on vaginal wall sensibility, vaginal vasocongestion, and sexual function: a prospective single-center study

    NARCIS (Netherlands)

    Weber, Maaike A.; Lakeman, Marielle M. E.; Laan, Ellen; Roovers, Jan-Paul W. R.

    2014-01-01

    Vaginal mesh surgery in patients with pelvic organ prolapse (POP) has been associated with sexual dysfunction. Implantation of synthetic mesh might damage vaginal innervation and vascularization, which could cause sexual dysfunction. We aim to evaluate the effects of vaginal mesh surgery on vaginal

  12. Vaginal Calculus in a Woman With Mixed Urinary Incontinence and Vaginal Mesh Exposure.

    Science.gov (United States)

    Winkelman, William D; Rabban, Joseph T; Korn, Abner P

    2016-01-01

    Vaginal calculi are extremely rare and are most commonly encountered in the setting of an urethrovaginal or vesicovaginal fistula. We present a case of a 72-year-old woman with mixed urinary incontinence and vaginal mesh exposure incidentally found to have a large vaginal calculus. We removed the calculus surgically and analyzed the components. Results demonstrated the presence of ammonium-magnesium phosphate hexahydrate and carbonate apatite.

  13. Pure transvaginal excision of mesh erosion involving the bladder.

    Science.gov (United States)

    Firoozi, Farzeen; Goldman, Howard B

    2013-06-01

    We present a pure transvaginal approach to the removal of eroded mesh involving the bladder secondary to placement of transvaginal mesh for management of pelvic organ prolapse (POP) using a mesh kit. Although technically challenging, we demonstrate the feasibility of a purely transvaginal approach, avoiding a potentially more morbid transabdominal approach. The video presents the surgical technique of pure transvaginal excision of mesh erosion involving the bladder after mesh placement using a prolapse kit was performed. This video shows that purely transvaginal removal of mesh erosion involving the bladder can be done safely and is feasible.

  14. Current role of mesh in vaginal prolapse surgery.

    Science.gov (United States)

    Richter, Lee A; Carter, Charelle; Gutman, Robert E

    2014-10-01

    This report summarizes the latest literature on transvaginal mesh (TVM) for the treatment of pelvic organ prolapse, with a focus on indications for use and management of complications. We describe trends in TVM by reviewing the recent literature and summarizing national meeting presentations. Vaginal mesh complications are most often managed surgically, and the majority of patients experiencing mesh-related pain have symptom improvement after intervention. New efforts will focus on identifying variables associated with success after intervention for mesh-related complications, to aid reconstructive pelvic surgeons in outcome prediction and patient counselling. Although the use of TVM has plateaued in recent years, we are seeing an exponential rise in synthetic mesh implant removal. Reconstructive pelvic surgeons advising patients with TVM complications should report that surgical intervention is often necessary, improvement rates of pain-related symptoms after surgery are high, and up to a third may require multiple interventions.

  15. High rate of vaginal erosions associated with the mentor ObTape.

    Science.gov (United States)

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  16. The Role of Chronic Mesh Infection in Delayed-Onset Vaginal Mesh Complications or Recurrent Urinary Tract Infections: Results From Explanted Mesh Cultures.

    Science.gov (United States)

    Mellano, Erin M; Nakamura, Leah Y; Choi, Judy M; Kang, Diana C; Grisales, Tamara; Raz, Shlomo; Rodriguez, Larissa V

    2016-01-01

    Vaginal mesh complications necessitating excision are increasingly prevalent. We aim to study whether subclinical chronically infected mesh contributes to the development of delayed-onset mesh complications or recurrent urinary tract infections (UTIs). Women undergoing mesh removal from August 2013 through May 2014 were identified by surgical code for vaginal mesh removal. Only women undergoing removal of anti-incontinence mesh were included. Exclusion criteria included any women undergoing simultaneous prolapse mesh removal. We abstracted preoperative and postoperative information from the medical record and compared mesh culture results from patients with and without mesh extrusion, de novo recurrent UTIs, and delayed-onset pain. One hundred seven women with only anti-incontinence mesh removed were included in the analysis. Onset of complications after mesh placement was within the first 6 months in 70 (65%) of 107 and delayed (≥6 months) in 37 (35%) of 107. A positive culture from the explanted mesh was obtained from 82 (77%) of 107 patients, and 40 (37%) of 107 were positive with potential pathogens. There were no significant differences in culture results when comparing patients with delayed-onset versus immediate pain, extrusion with no extrusion, and de novo recurrent UTIs with no infections. In this large cohort of patients with mesh removed for a diverse array of complications, cultures of the explanted vaginal mesh demonstrate frequent low-density bacterial colonization. We found no differences in culture results from women with delayed-onset pain versus acute pain, vaginal mesh extrusions versus no extrusions, or recurrent UTIs using standard culture methods. Chronic prosthetic infections in other areas of medicine are associated with bacterial biofilms, which are resistant to typical culture techniques. Further studies using culture-independent methods are needed to investigate the potential role of chronic bacterial infections in delayed vaginal mesh

  17. Do patients prefer mesh or anterior colporrhaphy for primary correction of anterior vaginal wall prolapse: a labelled discrete choice experiment

    NARCIS (Netherlands)

    Notten, K. J. B.; Essers, B. A.; Weemhoff, M.; Rutten, A. G. H.; Donners, J. J. A. E.; van Gestel, I.; Kruitwagen, R. F. M. P.; Roovers, J. P. W. R.; Dirksen, C. D.

    2015-01-01

    We investigated patients' preferences for anterior colporrhaphy or mesh surgery as surgical correction of anterior vaginal wall prolapse. Labelled discrete choice experiment. Three Dutch teaching hospitals. Women with anterior vaginal wall prolapse Pelvic Organ Prolapse Quantification stage 2 or

  18. Anterior six arms prolene mesh for high stage vaginal prolapse: five years follow-up

    Directory of Open Access Journals (Sweden)

    Luis Gustavo M. de Toledo

    Full Text Available ABSTRACT Introduction In high stage vaginal prolapse, recurrence risk patients, anterior and apical defects need to be addressed in the same procedure. The pre-molded commercial mesh kits are expensive and not always available. Alternative effective and safe treatment ways, with lower costs are desirable. Objective To present long term follow-up of patients treated with a homemade mesh shape to correct high stage prolapses. Materials and Methods We describe prospectively 18 patients with anterior and apical vaginal prolapses, stages III and IV, repaired using this specific design of mesh. All patients were submitted to pre-operative clinical evaluation and urodynamics. Prolapse was classified using the pelvic organ prolapse quantification (POP-Q. Intervention Prolapse surgery, using a six arms prolene mesh, through a single anterior vaginal incision. Outcome Measurements: POP-Q, patients satisfaction, descriptive statistical analysis. Results Between February 2009 and Oct 2010, 18 consecutive women underwent the above-mentioned surgery. Mean age was 68 years. At a mean follow-up of .,4 years (5 to 5.8 years, 16 (89% patients were continent, mean Ba point came from +4.7cm to - 2.5cm, mean C point from +2.8cm to -6.6cm and mean Bp point from +1.3 to -1.7cm. There were two (11% objective failures, but all the patients were considered success subjectively. There were two cases of mesh vaginal extrusion. Conclusions The homemade six arms prolene mesh allows concomitant correction of anterior and apical prolapses, through a single anterior vaginal incision, being an effective, safe and affordable treatment option when mesh is needed.

  19. The use of mesh implants in vaginal prolapse surgery: Position ...

    African Journals Online (AJOL)

    sponsored training have also played a role in the adoption of these new techniques. .... surface area and weight of type 1 polypropylene mesh used in different kits, make ... such as bladder and rectal injury, and further recurrence. Realistic.

  20. The use of mesh implants in vaginal prolapse surgery: Position ...

    African Journals Online (AJOL)

    Abstract. This is the 2014 updated guideline and position statement from the South African Urogynaecology Association on the use of transvaginal mesh for the surgical correction of pelvic organ prolapse.

  1. Long-term quality-of-life outcome after mesh sacrocolpopexy for vaginal vault prolapse.

    LENUS (Irish Health Repository)

    Thomas, Arun Z

    2009-12-01

    To evaluate the long-term outcome of mesh sacrocolpopexy (MSC, which aims to restore normal pelvic floor anatomy to alleviate prolapse related symptoms) and its effect on patient\\'s quality of life, as women with vaginal vault prolapse commonly have various pelvic floor symptoms that can affect urinary, rectal and sexual function.

  2. Laparoscopy-like operative vaginoscopy: a new approach to manage mesh erosions.

    Science.gov (United States)

    Billone, Valentina; Amorim-Costa, Célia; Campos, Sara; Rabischong, Benoĭt; Bourdel, Nicolas; Canis, Michel; Botchorishvili, Revaz

    2015-01-01

    Mesh erosion through the vagina is the most common complication of synthetic mesh used for pelvic organ prolapse repair. However, conventional transvaginal mesh excision has many technical limitations. We aimed at creating and describing a new surgical technique for transvaginal removal of exposed mesh that would enable better exposition and access, thus facilitating optimal treatment. A step-by-step video showing the technique. A university tertiary care hospital. Five patients previously submitted to pelvic organ prolapse repair using synthetic mesh, presenting mesh erosion through the vagina. Mesh excision using a laparoscopy-like operative vaginoscopy in which standard laparoscopic instruments are used through a single-incision laparoscopic surgery port device placed in the vagina. In all cases, a very good exposure of the mesh was achieved, a minimal tissue traction was required, and the procedures were performed in a very ergonomic way. All the patients were discharged on the same day of the surgery and had a painless postoperative course. So far, there have been no cases of relapse. This seems to be a simple, cheap, and valuable minimally invasive technique with many advantages in comparison with the conventional approach. More cases and time are necessary to access its long-term efficacy. It may possibly be used for the management of other conditions. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  3. [Vaginal mesh operations in the urogynecological practice after the FDA warnings. Use or not to use mesh?

    Science.gov (United States)

    Fekete, Zoltán; Körösi, Szilvia; Németh, Gábor

    2018-03-01

    The prevalence of pelvic organ prolapse (POP) with aging is escalating alarmingly, and now becoming a growing epidemic among the elderly. Synthetic transvaginal mesh (TVM) has been employed with increasing popularity in the treatment of POP until the end of the last decade. After the U.S. Drug and Food Administration (FDA) warnings in the years 2008 and 2011, the number of vaginal mesh operations has decreased dramatically. The aim of the study was to evaluate and compare the anti-POP effectivity, the anti-stress incontinence (anti-SUI) efficacy, and the late (36 months) post-operative complications of the anterior vaginoplasty and the TVM operations. We analysed the clinical data from 120 patients with stage II-III anterior prolapse and concomitant SUI who had undergone surgery at a tertiary referral centre in Hungary between January 2013 and January 2014. Sixty patients underwent Kelly-Stoeckel vaginoplasty and the other 60 cases had TVM operation. The surgical complications were classified using the Clavien-Dindo (CD) classification system. The anti-POP (91.6% vs. 63.3%; pmesh surgery represents an effective procedure for prolapse and concomitant SUI with a decreased risk of short- and long-term complications. Orv Hetil. 2018; 159(10): 397-404.

  4. Sentiment Analysis of Web Sites Related to Vaginal Mesh Use in Pelvic Reconstructive Surgery.

    Science.gov (United States)

    Hobson, Deslyn T G; Meriwether, Kate V; Francis, Sean L; Kinman, Casey L; Stewart, J Ryan

    2018-05-02

    The purpose of this study was to utilize sentiment analysis to describe online opinions toward vaginal mesh. We hypothesized that sentiment in legal Web sites would be more negative than that in medical and reference Web sites. We generated a list of relevant key words related to vaginal mesh and searched Web sites using the Google search engine. Each unique uniform resource locator (URL) was sorted into 1 of 6 categories: "medical", "legal", "news/media", "patient generated", "reference", or "unrelated". Sentiment of relevant Web sites, the primary outcome, was scored on a scale of -1 to +1, and mean sentiment was compared across all categories using 1-way analysis of variance. Tukey test evaluated differences between category pairs. Google searches of 464 unique key words resulted in 11,405 URLs. Sentiment analysis was performed on 8029 relevant URLs (3472 legal, 1625 "medical", 1774 "reference", 666 "news media", 492 "patient generated"). The mean sentiment for all relevant Web sites was +0.01 ± 0.16; analysis of variance revealed significant differences between categories (P Web sites categorized as "legal" and "news/media" had a slightly negative mean sentiment, whereas those categorized as "medical," "reference," and "patient generated" had slightly positive mean sentiments. Tukey test showed differences between all category pairs except the "medical" versus "reference" in comparison with the largest mean difference (-0.13) seen in the "legal" versus "reference" comparison. Web sites related to vaginal mesh have an overall mean neutral sentiment, and Web sites categorized as "medical," "reference," and "patient generated" have significantly higher sentiment scores than related Web sites in "legal" and "news/media" categories.

  5. A 52-month follow-up on the transvaginal mesh surgery in vaginal cuff eversion.

    Science.gov (United States)

    Lo, Tsia-Shu; Yusoff, Faridah Mohd; Kao, Chuan-Chi; Jaili, Sukanda; Uy Patrimonio, Ma Clarissa

    2017-06-01

    Transvaginal mesh anterior-posterior (TVM-AP) provides better cure rates in the surgical treatment of vaginal cuff eversion than anterior transvaginal mesh combined with sacrospinous ligament fixation (TVM-A). We determine the outcomes after TVM-A and TVM-AP surgeries in advanced vaginal cuff prolapse. The charts of 796 women who underwent pelvic organ prolapse (POP) surgery from July 2006 to January 2012 in Chang Gung Memorial Hospitals were reviewed. We included women who presented with advanced cuff eversion and treated with TVM surgery. Data were analysed after three years post-surgery. Descriptive statistics were used for demographic and perioperative data. The paired-samples t test was used for comparison of preoperative and postoperative continuous data. The outcomes measured were objective cure (POP-Q stage ≤ 1) and subjective cure (negative response to question 2 and 3 on POPDI-6). A total of 97 patients was analysed. 61 patients had TVM-A and 36 patients had TVM-AP insertion. Mean follow-up was 52 months. The objective cure rate for TVM-AP was significantly higher than TVM-A, 94.4% versus 80.3%. TVM-AP also showed a higher subjective cure rate (91.7%) though there was no significant difference from TVM-A (p = 0.260). The mesh extrusion rate was low at 3.1% with no major complications seen. In TVM-A the blood loss was lesser and the operation time was shorter. TVM-AP showed better objective cure rate than TVM-A at 52 months. However, TVM-A is less invasive in comparison with an acceptably good cure rates. Copyright © 2017. Published by Elsevier B.V.

  6. Trans-Vaginal Mesh Revision: A Comprehensive Review on Etiologies and Management Strategies with Emphasis on Postoperative Pain Outcomes.

    Science.gov (United States)

    Mock, Stephen; Reynolds, William S; Dmochowski, Roger R

    2014-05-01

    The use of polypropylene mesh to augment surgery aimed to correct pelvic organ prolapse and stress urinary incontinence stems largely from the high recurrence rates of native tissue repairs. While objective outcomes were improved, mesh related complications began to emerge that included mesh exposures, extrusions, dyspareunia and other pain issues. However, the indication for and benefit of surgical intervention(s) to address these complications are lacking. We aim to review to current literature regarding postoperative pain outcomes following vaginal mesh revision. Evidence based literature indicates that mesh complications are not rare and surgery that aims to address them generally have an overall benefit. However, studies available are generally small case series of a retrospective nature with short follow up. Some themes are evident: there is a long lag period from mesh insertion to removal; there is a lack of a true denominator of total mesh insertions making it hard to gauge the real scope of the problem; mesh material found not along the expected trocar path or coursing close to neurovascular structures thus raises the possibility of technical errors during insertion. Transvaginal mesh revision(s) for mesh complications generally have a positive effect on pain outcomes, but better controlled studies are needed. Additionally, since technical issues may be a factor in the development of mesh complications, rigorous training and sufficient surgical case volume should be emphasized. © 2014 Wiley Publishing Asia Pty Ltd.

  7. Clinical observation of a modified surgical method: posterior vaginal mesh suspension of female rectocele with intractable constipation.

    Science.gov (United States)

    Hong, Ling; Li, Huai-Fang; Sun, Jing; Zhu, Jian-Long; Ai, Gui-hai; Li, Li; Zhang, Bo; Chi, Feng-li; Tong, Xiao-Wen

    2012-01-01

    To explore the feasibility and effectiveness of a modified posterior vaginal mesh suspension method in treating female rectocele with intractable constipation. Descriptive study (Canadian Task Force classification II-3). The study was performed in the Study Center for Female Pelvic Dysfunction Disease, Department of Obstetrics and Gynecology, Tongji Hospital, Tongji University School of Medicine, Shanghai, China. The Study Center includes 15 physicians, most of whom have received advanced training in pelvic floor dysfunctional disease and can skillfully perform many types of operations in patients with such disease. Almost 1500 operations to treat pelvic floor dysfunctional disease are performed every year at the center. Thirty-six women with rectocele with intractable constipation. Posterior vaginal mesh suspension. All patients were followed up for 15 to 36 months. In 29 patients, the condition was cured completely; in 5 patients it had improved; and in 2 patients, the intervention had no effect. Insofar as recovery and improved results, the overall effectiveness rate was 94.4%. Posterior vaginal mesh suspension is an effective, harmless, and convenient method for treatment of female rectocele with intractable constipation. It has positive short-term curative effects, with few complications and sequelae. However, the long-term effects of posterior vaginal mesh suspension should be evaluated. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.

  8. Complications of grafts used in female pelvic floor reconstruction: Mesh erosion and extrusion

    Directory of Open Access Journals (Sweden)

    Tanya M Nazemi

    2007-01-01

    Full Text Available Introduction: Various grafts have been used in the treatment of urinary incontinence and pelvic prolapse. Autologous materials such as muscle and fascia were first utilized to provide additional anatomic support to the periurethral and pelvic tissues; however, attempts to minimize the invasiveness of the procedures have led to the use of synthetic materials. Complications such as infection and erosion or extrusion associated with these materials may be troublesome to manage. We review the literature and describe a brief overview of grafts used in pelvic floor reconstruction and focus on the management complications specifically related to synthetic materials. Materials and Methods: We performed a comprehensive review of the literature on grafts used in pelvic floor surgery using MEDLINE and resources cited in those peer-reviewed manuscripts. The results are presented. Results: Biologic materials provide adequate cure rates but have associated downfalls including potential complications from harvesting, variable tissue quality and cost. The use of synthetic materials as an alternative graft in pelvic floor repairs has become a popular option. Of all synthetic materials, the type I macroporous polypropylene meshes have demonstrated superiority in terms of efficacy and fewer complication rates due to their structure and composition. Erosion and extrusion of mesh are common and troublesome complications that may be managed conservatively with observation with or without local hormone therapy, with transvaginal debridement or with surgical exploration and total mesh excision, dependent upon the location of the mesh and the mesh type utilized. Conclusions: The ideal graft would provide structural integrity and durability with minimal adverse reaction by the host tissue. Biologic materials in general tend to have fewer associated complications, however, the risks of harvesting, variable integrity of allografts, availability and high cost has led to the

  9. Indications and Complications Associated with the Removal of 506 Pieces of Vaginal Mesh Used in Pelvic Floor Reconstruction: A Multicenter Study.

    Science.gov (United States)

    Miklos, John R; Chinthakanan, Orawee; Moore, Robert D; Karp, Deborah R; Nogueiras, Gladys M; Davila, G Willy

    2016-10-26

    Synthetic mesh utilized to treat stress urinary incontinence (SUI) and pelvic organ prolapse (POP) can often result in postoperative complications. The objectives of this study were to determine: 1) the most common indications for mesh removal; 2) the incidences of the removal of specific mesh procedures (such as suburethral sling [SUS], transvaginal mesh [TVM], or sacrocolpopexy); and 3) the idences and types of surgical complications associated with mesh removal. This was a retrospective study. Design Classification: Canadian Task Force II-3. Three tertiary referral centers in the United States. We examined data from all patients at the three centers who underwent surgical removal of synthetic materials from previous SUS, TVM, and sacrocolpopexy procedures for mesh-related complications from 2011 to 2013. Patients underwent vaginal, intra-abdominal, and inguinal mesh revisions by cutting, partial removal, or total removal of the mesh for mesh-related complications. Overall, 445 patients with complications underwent mesh removal laparoscopically, via groin dissection and/or transvaginally. There were a total of 506 mesh products removed. Of these, 56.5% were slings and 43.5% were for pelvic organ prolapse (POP). Synthetic mesh removed from patients included: transvaginal mesh (TVM) anterior for anterior vaginal prolapse, TVM posterior for posterior vaginal prolapse, sacrocolpopexy mesh, and suburethral slings (SUS) for stress urinary incontinence. Synthetic SUS removed included: retropubic (RPS), transobturator (TOT), and single-incision slings (SIS). TOT was the most common type of sling removed. Patients with a sling who only complained of vaginal pain with or without intercourse underwent a vaginal approach for surgical revision/removal of the sling (86.6%). Patients with an RPS with lower abdominal/suprapubic pain and vaginal pain underwent a vaginal and laparoscopic approach for sling removal (18.4%). Patients with a TOT sling who complained of vaginal and

  10. Laparoscopic Pelvic Floor Repair Using Polypropylene Mesh

    Directory of Open Access Journals (Sweden)

    Shih-Shien Weng

    2008-09-01

    Conclusion: Laparoscopic pelvic floor repair using a single piece of polypropylene mesh combined with uterosacral ligament suspension appears to be a feasible procedure for the treatment of advanced vaginal vault prolapse and enterocele. Fewer mesh erosions and postoperative pain syndromes were seen in patients who had no previous pelvic floor reconstructive surgery.

  11. Outcome of Treatment of Anterior Vaginal Wall Prolapse and Stress Urinary Incontinence with Transobturator Tension-Free Vaginal Mesh (Prolift and Concomitant Tension-Free Vaginal Tape-Obturator

    Directory of Open Access Journals (Sweden)

    Sameh Azazy

    2008-12-01

    Full Text Available Objective. It is to assess the feasibility, effectiveness, and safety of transobturator tension-free vaginal mesh (Prolift and concomitant tension-free vaginal tape-obturator (TVT-O system as a treatment of female anterior vaginal wall prolapse associated with stress urinary incontinence (SUI. Patients and Methods. Between December 2006 and July 2007, 20 patients with anterior genital prolapse and voiding dysfunction were treated with the transobturator tension-free vaginal mesh (Prolift and concomitant tension-free vaginal tape-obturator (TVT-O. Sixteen patients had stress urinary incontinence and 4 patients were considered at risk for development of de novo stress incontinence after the prolapse is repaired. All patients underwent a complete urodynamic assessment. All the patients underwent pelvic examination 4–6 weeks after the operation, and anatomical and functional outcomes were recorded. Results. Twenty cystocoeles were repaired: 6 grade II, 12 grade III, and 2 grade IV. There were no vessel or bladder injuries. Eighteen patients had optimal anatomic results and 2 patients had persistent asymptomatic stage I prolapse. Conclusion. These preliminary results suggest that Prolift system offers a safe and effective treatment for female anterior vaginal wall prolapse. However, a long-term followup is necessary in order to support the good result maintenance.

  12. Laparoscopic removal of mesh used in pelvic floor surgery.

    Science.gov (United States)

    Khong, Su-Yen; Lam, Alan

    2009-01-01

    Various meshes are being used widely in clinical practice for pelvic reconstructive surgery despite the lack of evidence of their long-term safety and efficacy. Management of complications such as mesh erosion and dyspareunia can be challenging. Most mesh-related complications can probably be managed successfully via the transvaginal route; however, this may be impossible if surgical access is poor. This case report demonstrates the successful laparoscopic removal of mesh after several failed attempts via the vaginal route.

  13. Native tissue repair or transvaginal mesh for recurrent vaginal prolapse: what are the long-term outcomes?

    Science.gov (United States)

    Ow, Lin Li; Lim, Yik N; Dwyer, Peter L; Karmakar, Debjyoti; Murray, Christine; Thomas, Elizabeth; Rosamilia, Anna

    2016-09-01

    The objective of this study was to assess outcomes in native tissue (NT) and transvaginal mesh (TVM) repair in women with recurrent prolapse. A retrospective two-group observational study of 237 women who underwent prolapse repair after failed NT repair in two tertiary hospitals. A primary outcome of "success" was defined using a composite outcome of no vaginal bulge symptoms, no anatomical recurrence in the same compartment beyond the hymen (0 cm on POPQ) and no surgical re-treatment for prolapse in the same compartment. Secondary outcomes assessed included re-operation for prolapse in the same compartment, dyspareunia and mesh-related complications. Of a total of 336 repairs, 196 were performed in the anterior compartment and 140 in the posterior compartment. Compared with the TVM groups, women undergoing repeat NT repair were more likely to experience anatomical recurrence (anterior 40.9 % vs 25 %, p = 0.02, posterior 25.3 % vs 7.5 %, p = 0.01), report vaginal bulge (anterior 34.1 % vs 12 %, p mesh exposure were 9.3 % anteriorly and 15.1 % posteriorly. Although the number of women requiring a prolapse re-operation is lower in the TVM group, the overall re-operation rate was not significantly different when procedures to correct mesh complications were included. Although the success rate is better with the use of TVM for recurrent prolapse, the total re-operation rates are similar when mesh complication-related surgeries are included.

  14. Vaginitis

    Science.gov (United States)

    ... change in discharge. What treatments are available for vaginal yeast infection? Yeast infections can be treated either by placing ... of organisms that are normally found in the vagina. Candidiasis: Also called yeast infection or moniliasis, a type ...

  15. Does the Vaginal Flora Modify When a Synthetic Mesh is Used for Genital Prolapse Repair in Postmenopausal Women? A Pilot, Randomized Controlled Study.

    Science.gov (United States)

    de Castro, Edilson Benedito; Brito, Luiz Gustavo Oliveria; Giraldo, Paulo César; Teatin Juliato, Cássia Raquel

    2018-01-10

    The vaginal flora from postmenopausal women with pelvic organ prolapse (POP) is different from younger women. We hypothesized that the decision of a surgical route using a mesh would modify the vaginal flora. The purpose of this study was to analyze the vaginal flora from postmenopausal women that were submitted to abdominal sacrocervicopexy or vaginal sacrospinous fixation. A pilot, randomized controlled study with 50 women aged 55 to 75 years (n = 25; abdominal sacrocervicopexy + subtotal hysterectomy; n = 25 vaginal sacrospinous fixation + vaginal hysterectomy) was performed. A polyvinylidene mesh was used in both arms. The vaginal content analysis was collected before and 60 days after the surgery. The type of flora, the presence of lactobacilli/leukocytes, and the Nugent criteria were analyzed. Most of the women were white (80%), with at least 1 comorbidity (69.9%), did not present sexual activity (60%), and presented advanced stage 4 POP. Two thirds of women presented a type 3 flora, and half of them did not present lactobacilli (48.3%). About the Nugent criteria, 51.7% presented normal flora, 46.6% found altered flora, and 1.7% had bacterial vaginosis. There were no differences about the type of flora (P = 1), number of lactobacilli (P = 0.9187), Nugent criteria (P = 0.4235), inflammation (P = 0.1018), and bacterial vaginosis (P = 0.64) before and after surgery in both groups. In this pilot study, the use of synthetic mesh by vaginal or abdominal route did not affect the vaginal flora in postmenopausal women operated on by POP surgery.

  16. The Role of Vaginal Mesh Procedures in Pelvic Organ Prolapse Surgery in View of Complication Risk

    OpenAIRE

    Ellington, David R.; Richter, Holly E.

    2013-01-01

    Synthetic transvaginal mesh has been employed in the treatment of pelvic organ prolapse for more than a decade. As the use of these devices increased during this period so did adverse event reporting. In 2008, the Food and Drug Administration (FDA) Public Health Notification informed physicians and patients of rising concerns with the use of synthetic transvaginal mesh. Shortly thereafter and in parallel to marked increases in adverse event reporting within the Manufacturer and User Device E...

  17. The Role of Vaginal Mesh Procedures in Pelvic Organ Prolapse Surgery in View of Complication Risk

    Directory of Open Access Journals (Sweden)

    David R. Ellington

    2013-01-01

    Full Text Available Synthetic transvaginal mesh has been employed in the treatment of pelvic organ prolapse for more than a decade. As the use of these devices increased during this period so did adverse event reporting. In 2008, the Food and Drug Administration (FDA Public Health Notification informed physicians and patients of rising concerns with the use of synthetic transvaginal mesh. Shortly thereafter and in parallel to marked increases in adverse event reporting within the Manufacturer and User Device Experience (MAUDE, the FDA released a Safety Communication regarding urogynecologic surgical mesh use. Following this report and in the wake of increased medical industry product withdrawal, growing medicolegal concerns, patient safety, and clinical practice controversy, many gynecologists and pelvic reconstructive surgeons are left with limited long-term data, clinical guidance, and growing uncertainty regarding the role of synthetic transvaginal mesh use in pelvic organ prolapse. This paper reviews the reported complications of synthetic transvaginal mesh with an evidence-based approach as well as providing suggested guidance for the future role of its use amidst the controversy.

  18. The Role of Vaginal Mesh Procedures in Pelvic Organ Prolapse Surgery in View of Complication Risk

    Science.gov (United States)

    Ellington, David R.; Richter, Holly E.

    2013-01-01

    Synthetic transvaginal mesh has been employed in the treatment of pelvic organ prolapse for more than a decade. As the use of these devices increased during this period so did adverse event reporting. In 2008, the Food and Drug Administration (FDA) Public Health Notification informed physicians and patients of rising concerns with the use of synthetic transvaginal mesh. Shortly thereafter and in parallel to marked increases in adverse event reporting within the Manufacturer and User Device Experience (MAUDE), the FDA released a Safety Communication regarding urogynecologic surgical mesh use. Following this report and in the wake of increased medical industry product withdrawal, growing medicolegal concerns, patient safety, and clinical practice controversy, many gynecologists and pelvic reconstructive surgeons are left with limited long-term data, clinical guidance, and growing uncertainty regarding the role of synthetic transvaginal mesh use in pelvic organ prolapse. This paper reviews the reported complications of synthetic transvaginal mesh with an evidence-based approach as well as providing suggested guidance for the future role of its use amidst the controversy. PMID:24069035

  19. A 3-year follow-up after anterior colporrhaphy compared with collagen-coated transvaginal mesh for anterior vaginal wall prolapse

    DEFF Research Database (Denmark)

    Rudnicki, Martin; Laurikainen, E; Pogosean, R

    2016-01-01

    departments of obstetrics and gynaecology in Norway, Sweden, Finland, and Denmark. POPULATION: A total of 138 women, of 55 years of age or older, admitted for stage ≥2 anterior vaginal wall prolapse. METHODS: The women scheduled for primary anterior vaginal wall prolapse surgery were randomised between...... the groups was observed regarding PFIQ-7, PFDI-20, and Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) scores. The number of mesh exposures did not change during the study period and all exposures were minor. CONCLUSION: Our study demonstrates that although the objective outcome...

  20. Evaluation of air jet erosion profiles in metal mesh supported SCR plate catalyst based on glass fiber concentrations

    Science.gov (United States)

    Rajath, S.; Nandakishora, Y.; Siddaraju, C.; Roy, Sukumar

    2018-04-01

    This paper explains the evaluation of erosion profiles in metal mesh supported SCR plate catalyst structures in which the glass fibers concentration in the catalyst material is considered as prime factor for erosion resistance and mechanical strength. The samples are prepared and tested at the specified and constant conditions like velocity as 30m/s, sand flow rate as 2g/min, average particle diameter 300 µm and all these samples were tested at different angles at impact preferably 15°,30°,45°,60°,75°,and 90° as per ASTM G76 standards. Say, if 5% glass fibers are present in catalyst material, then erosion resistance increases, but the density of glass fibers is very less because each glass fiber is approximately 20 microns in diameter and weight of individual is negligible. The composition in which 2% fiber is present has slightly higher erosion comparatively, but 3% glass fibers or more foreign inclusion like excessive binders can be eliminated that contributes much for the conversion of NOx. So 2% -3% glass fibers are preferred and optimized based on NOx conversion and erosion resistance property.

  1. Suburethral Slingplasty Using a Self-fashioned Gynemesh for Treating Urinary Incontinence and Anterior Vaginal Wall Prolapse

    Directory of Open Access Journals (Sweden)

    Chi-Feng Su

    2009-03-01

    Conclusion: We found that using self-fashioned Gynemesh for tension-free suburethral and anterior vaginal slingplasty provided a high success rate (97% in the 3 years of follow-up. Mechanical rejection may be one of the causes of vaginal mesh erosion.

  2. Symptom resolution after operative management of complications from transvaginal mesh.

    Science.gov (United States)

    Crosby, Erin C; Abernethy, Melinda; Berger, Mitchell B; DeLancey, John O; Fenner, Dee E; Morgan, Daniel M

    2014-01-01

    Complications from transvaginal mesh placed for prolapse often require operative management. The aim of this study is to describe the outcomes of vaginal mesh removal. A retrospective review of all patients having surgery by the urogynecology group in the department of obstetrics and gynecology at our institution for a complication of transvaginal mesh placed for prolapse was performed. Demographics, presenting symptoms, surgical procedures, and postoperative symptoms were abstracted. Comparative statistics were performed using the χ or Fisher's exact test with significance at Pmesh and 84 had follow-up data. The most common presenting signs and symptoms were: mesh exposure, 62% (n=56); pain, 64% (n=58); and dyspareunia, 48% (n=43). During operative management, mesh erosion was encountered unexpectedly in a second area of the vagina in 5% (n=4), in the bladder in 1% (n=1), and in the bowel in 2% (n=2). After vaginal mesh removal, 51% (n=43) had resolution of all presenting symptoms. Mesh exposure was treated successfully in 95% of patients, whereas pain was only successfully treated in 51% of patients. Removal of vaginal mesh is helpful in relieving symptoms of presentation. Patients can be reassured that exposed mesh can almost always be successfully managed surgically, but pain and dyspareunia are only resolved completely in half of patients. III.

  3. Transvaginal Excision of an Eroded Sacrocolpopexy Mesh by Using Single-Incision Laparoscopic Surgery Equipment.

    Science.gov (United States)

    Mohr, Stefan; Siegenthaler, Franziska; Imboden, Sara; Kuhn, Annette; Mueller, Michael D

    To show a new technique of using single-incision laparoscopic surgery (SILS) equipment in vaginal surgery to create a "pneumovagina." Explanatory video demonstrating the technique and intraoperative findings. University hospital. The 68-year-old patient was referred with a vaginal mesh erosion that resulted in abscess formation at the vaginal apex. The patient was symptomatic with an increasingly foul-smelling vaginal discharge for about 1 year. She had a laparoscopic sacrocolpopexy in a remote hospital 22 months before the current operation and had a total abdominal hysterectomy 15 years ago. The, patient's history was uneventful without dyspareunia, incontinence or voiding difficulties, and she was otherwise content with the sacrocolpopexy result. The local institutional review board granted exemption for this publication. Frequently, pelvic organ prolapse can only be effectively treated if the surgical procedure comprises support of the central compartment. Laparoscopic sacrocolpopexy shows superior outcomes for this indication, with success rates of up to 96%. However, a rare side effect of laparoscopic sacrocolpopexy is mesh erosion, occurring in up to 2.4% [1]. These erosions are usually treated laparoscopically [2]. In this video we show an alternative route for excision of a symptomatic exposed mesh by using a transvaginal approach: The SILS trocar is used vaginally for abscess irrigation and mesh excision with minimally invasive instruments. For treatment of the abscess and removal of the exposed mesh, the SILS trocar was placed vaginally, and laparoscopic instruments were used. The abscess was incised, cleansed and irrigated, debrided, and the mesh excised. Because no mesh material was exposed after excision, the vagina was not closed to avoid creating a cavity with the risk of promoting reabscess formation, and secondary wound healing was anticipated. Laparoscopy was used to confirm that no intra-abdominal lesion coexisted or occurred. There were

  4. Mesh complications in female pelvic floor reconstructive surgery and their management: A systematic review

    Directory of Open Access Journals (Sweden)

    Hemendra N Shah

    2012-01-01

    Full Text Available We reviewed the incidence, predisposing factors, presentation and management of complications related to the use of synthetic mesh in the management of stress urinary incontinence and pelvic organ prolapse repair. Immediate complications, such as bleeding, hematoma, injury to adjacent organs during placement of mesh and complication of voiding dysfunction are not discussed in this review, since they are primarily related to technique. A PubMed search of related articles published in English was done from April 2008 to March 2011. Key words used were urinary incontinence, mesh, complications, midurethral sling, anterior prolapse, anterior vaginal repair, pelvic organ prolapse, transvaginal mesh, vault prolapse, midurethral slings, female stress urinary incontinence, mesh erosion, vaginal mesh complications, and posterior vaginal wall prolapse. Since there were very few articles dealing with the management of mesh-related complications in the period covered in the search we extended the search from January 2005 onwards. Articles were selected to fit the scope of the topic. In addition, landmark publications and Manufacturer and User Facility Device Experience (MAUDE data (FDA website were included on the present topic. A total of 170 articles were identified. The use of synthetic mesh in sub-urethral sling procedures is now considered the standard for the surgical management of stress urinary incontinence. Synthetic mesh is being increasingly used in the management of pelvic organ prolapse. While the incidence of extrusion and erosion with mid-urethral sling is low, the extrusion rate in prolapse repair is somewhat higher and the use in posterior compartment remains controversial. When used through the abdominal approach the extrusion and erosion rates are lower. The management of mesh complication is an individualized approach. The choice of the technique should be based on the type of mesh complication, location of the extrusion and/or erosion

  5. Mesh complications in female pelvic floor reconstructive surgery and their management: A systematic review

    Science.gov (United States)

    Shah, Hemendra N.; Badlani, Gopal H.

    2012-01-01

    We reviewed the incidence, predisposing factors, presentation and management of complications related to the use of synthetic mesh in the management of stress urinary incontinence and pelvic organ prolapse repair. Immediate complications, such as bleeding, hematoma, injury to adjacent organs during placement of mesh and complication of voiding dysfunction are not discussed in this review, since they are primarily related to technique. A PubMed search of related articles published in English was done from April 2008 to March 2011. Key words used were urinary incontinence, mesh, complications, midurethral sling, anterior prolapse, anterior vaginal repair, pelvic organ prolapse, transvaginal mesh, vault prolapse, midurethral slings, female stress urinary incontinence, mesh erosion, vaginal mesh complications, and posterior vaginal wall prolapse. Since there were very few articles dealing with the management of mesh-related complications in the period covered in the search we extended the search from January 2005 onwards. Articles were selected to fit the scope of the topic. In addition, landmark publications and Manufacturer and User Facility Device Experience (MAUDE) data (FDA website) were included on the present topic. A total of 170 articles were identified. The use of synthetic mesh in sub-urethral sling procedures is now considered the standard for the surgical management of stress urinary incontinence. Synthetic mesh is being increasingly used in the management of pelvic organ prolapse. While the incidence of extrusion and erosion with mid-urethral sling is low, the extrusion rate in prolapse repair is somewhat higher and the use in posterior compartment remains controversial. When used through the abdominal approach the extrusion and erosion rates are lower. The management of mesh complication is an individualized approach. The choice of the technique should be based on the type of mesh complication, location of the extrusion and/or erosion, its magnitude

  6. Surgical excision of eroded mesh after prior abdominal sacrocolpopexy.

    Science.gov (United States)

    South, Mary M T; Foster, Raymond T; Webster, George D; Weidner, Alison C; Amundsen, Cindy L

    2007-12-01

    We previously described an endoscopic-assisted transvaginal mesh excision technique. This study compares surgical outcomes after transvaginal mesh excision vs endoscopic-assisted transvaginal mesh excision. In addition, we reviewed our postoperative outcomes with excision via laparotomy. This was an inclusive retrospective analysis of patients presenting to our institution from 1997 to 2006 for surgical management of vaginal erosion of permanent mesh after sacrocolpopexy. Three techniques were utilized: transvaginal, endoscopic-assisted transvaginal, and laparotomy. For the patients undergoing transvaginal excision, data recorded included number and type of excisions performed, number of prior excisions performed at outside facilities, intraoperative and postoperative complications (including blood transfusions, pelvic abscess, or bowel complications), use of postoperative antibiotics, persistent symptoms of vaginal bleeding and discharge at follow-up, and demographic characteristics. The intraoperative and postoperative complications and the postoperative symptoms were recorded for the laparotomy cases. Thirty-one patients underwent transvaginal mesh excision during this time period: 17 endoscopic-assisted transvaginal and 14 transvaginal without endoscope assistance. In addition, a total of 7 patients underwent abdominal excision via laparotomy. Comparison of the 2 vaginal methods revealed no difference in the demographics or success rate, with success defined as no symptoms at follow-up. Endoscopic-assisted transvaginal excision was successful in 7 of 17 patients and transvaginal without endoscopic assistance in 9 of 13 patients (1 patient excluded for lack of follow-up data) for a total vaginal success rate of 53.3%. No intraoperative and only minor postoperative complications occurred with either vaginal method. Three patients underwent 3 vaginal attempts to achieve complete symptom resolution. The average follow-up time for the entire vaginal group was 14

  7. Comparing effectiveness of combined transobturator tension-free vaginal mesh (Perigee) and transobturator tension-free vaginal tape (TVT-O) versus anterior colporrhaphy and TVT-O for associated cystocele and urodynamic stress incontinence.

    Science.gov (United States)

    Lau, Hei-Yu; Twu, Nae-Fang; Chen, Yi-Jen; Horng, Huann-Cheng; Juang, Chi-Mou; Chao, Kuan-Chong

    2011-06-01

    To evaluate the efficacy and safety of transobturator tension-free vaginal mesh (Perigee) and concomitant transobturator tension-free vaginal tape (TVT-O) for treating cystocele with urodynamic stress incontinence (UDSI). A retrospective study of 115 patients with symptomatic stages 2-3 cystocele and UDSI who were treated with a Perigee system (Group I, n=68) plus TVT-O procedure or traditional anterior colporrhaphy (Group II, n=47) plus TVT-O procedure. All patients were followed up for more than one year. Objective and subjective symptoms were evaluated at one year postoperatively. Statistical analysis was performed using SPSS software. The objective cure rates for cystocele at one year were significantly higher in Group I than in Group II (98.5% and 86.9%, P=0.018), respectively. The cure rates for UDSI in the two groups were 91.0% vs. 91.3% (P=1.000). Symptomatic improvement of frequency was better in Group I than Group II (87.7% vs. 70.0%, P=0.030). There were no significant differences with regard to intraoperative and postoperative complications between the two groups. The combination of the Perigee system and TVT-O offers a safe and effective treatment for cystocele with UDSI and may be performed as first-line treatment. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Clinical challenges in the management of vaginal prolapse

    Directory of Open Access Journals (Sweden)

    Siddiqui NY

    2014-01-01

    Full Text Available Nazema Y Siddiqui, Autumn L EdenfieldDivision of Urogynecology and Reconstructive Surgery, Duke University Medical Center, Durham, NC, USAAbstract: Pelvic organ prolapse is highly prevalent, and negatively affects a woman’s quality of life. Women with bothersome prolapse may be offered pessary management or may choose to undergo corrective surgery. In choosing the most appropriate surgical procedure, there are many factors to consider. These may include the location(s of anatomic defects, the severity of prolapse symptoms, the activity level of the woman, and concerns regarding the durability of the repair. In many instances, women and their surgeons are challenged to weigh the risks and benefits of native tissue versus mesh-augmented repairs. Though mesh-augmented repairs may offer better durability, they are also associated with unique complications, such as mesh erosion. Furthermore, newer surgical techniques of mesh placement via abdominal or vaginal routes may result in different outcomes compared to traditional techniques. Biologic grafts may also be considered to improve durability of a surgical repair, while avoiding potential complications of synthetic mesh. In this article, we review many of the clinical challenges that gynecologic surgeons face in the surgical management of vaginal prolapse. Furthermore, we review data that can help guide decision making when treating women with pelvic organ prolapse.Keywords: pelvic organ prolapse, vaginal prolapse, surgery, sacrocolpopexy, sacrospinous ligament fixation, transvaginal mesh, uterosacral ligament suspension

  9. Ischiorectal abscess and ischiorectal-vaginal fistula as delayed complications of posterior intravaginal slingplasty: a case report.

    Science.gov (United States)

    Chen, Heidi Wen-Chu; Guess, Marsha K; Connell, Kathleen A; Bercik, Richard S

    2009-10-01

    Synthetic meshes have been used extensively to augment surgical management of pelvic organ prolapses. Posterior intravaginal sling (IVS) is a technique used for correcting vaginal vault/apical prolapse, posterior vaginal prolapse or rectocele. There are limited data on long-term safety of this procedure. In a subanalysis of the IVS tapes from the SUSPEND trial performed secondary to the large number of patients with complications of suburethral sling erosions after IVS, it was noted that the sling erosion tended to have a delayed presentation secondary to poor incorporation of the mesh. A 48-year-old woman with cystocele, uterine prolapse and rectocele had undergone total vaginal hysterectomy, mesh-augmented anterior repair, posterior colporrhaphy and posterior intravaginal slingplasty (IVS) in July 2005. Thirty months after the surgery, she presented with gradual symptoms of copious vaginal discharge for several weeks followed by constant right buttock pain and swelling. Examination was notable for intact mesh with no signs of erosion and a 3-cm induration deep within the right buttock. Computed tomography suggested a pelvic abscess. Magnetic resonance imaging confirmed a right ischiorectal fossa abscess and a vaginal fistula. The patient underwent sling excision, right ischiorectal fossa exploration and vaginal fistula repair. A fistulous tract was found to extend along the intact sling from the vaginal epithelium toward the right ischiorectal fossa. At 2 months' followup, there were no recurrences or other complications. This is the first report of a delayed complication of an ischiorectal abscess associated with an ischiorectal-vaginal fistula that presented 30 months after the placement of a posterior IVS.

  10. A THREE-YEAR EXPERIENCE WITH ANTERIOR TRANSOBTURATOR MESH (ATOM AND POSTERIOR ISCHIORECTAL MESH (PIRM

    Directory of Open Access Journals (Sweden)

    Marijan Lužnik

    2018-02-01

    . In all 11 cases correction was performed during the operation, mesh was kept in place and postoperative course of treatment went without complications. Mean hospitalization time for mesh operation was 4 to 5 days. Short term results, 2 to 3 months after the operation, are very good both for pelvic organ static, and for pelvic function. In 14 cases we had small vaginal erosion in place of upper vaginal incision by ATOM. All erosions were cured spontaneously after removing of unresorptive suture (Etibond 1/0; Ethicon and/or excision of small denudated mesh part (< 1 mm2 without any anesthesia and vaginal sutures. Conclusions. New methods and materials allow return of pelvic floor integrity to physiological condition without hysterectomy of otherwise healthy uterus also in state of totally uterine prolapse. Corrections of POP with mesh procedures and without hysterectomy present a minimally invasive surgery with short hospitalization and reconvalescence. Quality of life markedly improved after operation because the preoperative problems were eliminated. Our and foreign experiences on these field1–8 give us a promise for long duration of good results which we also expect for women after needle implanted mesh in ATOM and/or PIRM procedure.9, 10

  11. Mesh removal following transvaginal mesh placement: a case series of 104 operations.

    Science.gov (United States)

    Marcus-Braun, Naama; von Theobald, Peter

    2010-04-01

    The objective of the study was to reveal the way we treat vaginal mesh complications in a trained referral center. This is a retrospective review of all patients who underwent surgical removal of transvaginal mesh for mesh-related complications during a 5-year period. Eighty-three patients underwent 104 operations including 61 complete mesh removal, 14 partial excision, 15 section of sub-urethral sling, and five laparoscopies. Main indications were erosion, infection, granuloma, incomplete voiding, and pain. Fifty-eight removals occurred more than 2 years after the primary mesh placement. Mean operation time was 21 min, and there were two intraoperative and ten minor postoperative complications. Stress urinary incontinence (SUI) recurred in 38% and cystocele in 19% of patients. In a trained center, mesh removal was found to be a quick and safe procedure. Mesh-related complications may frequently occur more than 2 years after the primary operation. Recurrence was mostly associated with SUI and less with genital prolapse.

  12. [Current state of transvaginal meshes by resolution of pelvic organ prolapse].

    Science.gov (United States)

    Jírová, J; Pán, M

    Treatment of pelvic organs prolapse with transvaginal mesh kits represents nowadays a widespread surgical method, which partially replaced classic operations due to high success rate and low count of recurrences. Just like any other surgical method, the placement of transvaginal mesh is linked with occurrence of complications. In this article we attempt to review the more and less known facts about trans-vaginal meshes, their efficacy, count of recurrence and the spectrum of complications and we try to compare this technique with traditional surgical methods used to treat pelvic organs prolapse (without graft materials). Review. Department of Obstetrics and Gynecology, Regional hospital Mladá Boleslav a.s., Mladá Boleslav. Overview of the results of recent studies published in the Czech and English language in recent years. Pelvic organ prolapse repair with vaginal mesh has generally lower count of relapse especially in patients with wide genital hiatal area and with major levator ani avulsion. The spectrum of complications differs from classical techniques because of the presence of synthetic nonabsorbable material. Some of the specific complications we did not encounter during classical operations include vaginal mesh erosion, infection of mesh associated with chronic pelvic pain, dyspareunia, protrusion of the mesh into the closest organs or the rejection and progressive extrusion of the mesh. Primary enthusiasm has now been replaced with worries of major complications. Future tasks should therefore be aimed at minimizing the rate of complications associated with transvaginal meshes. Except using well-known and safe materials and providing specialized training of physicians for each mesh implantation technique, other precautions outlined in this article should help, such as a closer specification of indication for the application of transvaginal mesh.

  13. Clinical challenges in the management of vaginal prolapse

    Science.gov (United States)

    Siddiqui, Nazema Y; Edenfield, Autumn L

    2014-01-01

    Pelvic organ prolapse is highly prevalent, and negatively affects a woman’s quality of life. Women with bothersome prolapse may be offered pessary management or may choose to undergo corrective surgery. In choosing the most appropriate surgical procedure, there are many factors to consider. These may include the location(s) of anatomic defects, the severity of prolapse symptoms, the activity level of the woman, and concerns regarding the durability of the repair. In many instances, women and their surgeons are challenged to weigh the risks and benefits of native tissue versus mesh-augmented repairs. Though mesh-augmented repairs may offer better durability, they are also associated with unique complications, such as mesh erosion. Furthermore, newer surgical techniques of mesh placement via abdominal or vaginal routes may result in different outcomes compared to traditional techniques. Biologic grafts may also be considered to improve durability of a surgical repair, while avoiding potential complications of synthetic mesh. In this article, we review many of the clinical challenges that gynecologic surgeons face in the surgical management of vaginal prolapse. Furthermore, we review data that can help guide decision making when treating women with pelvic organ prolapse. PMID:24474848

  14. Transvaginal mesh in repair of pelvic organs prolapse as a minimally invasive surgical procedure

    Directory of Open Access Journals (Sweden)

    Argirović Rajka

    2011-01-01

    Full Text Available Background/Aim. Prolapse of genital organs with or without urinary stress incontinention is the most often health problem in the elderly female population tending to increase with ageing. The aim of this study was to assess the perioperative complications and short-term outcomes of prolaps repair using transvaginal polypropylene mesh (Prolift system, Gynecare, Ethicon, USA. Methods. A retrospective study was conducted evaluating 96 women from September 2006 to January 2010 who undewent vaginal repair with implatation of a soft mesh manufactured by Gynecare, Ethicon, USA. Results. All the patients had a stage 3 or stage 4 prolapse according to the POP-Q system of ICS. Total mesh was used in 12 (13% patients isolated anterior mesh in 52 (54% patients and isolated posterior mesh in 32 (33% patients. We reported one intra-operative bladder injury and no other serious complications. At 3 months, all 96 patients were available for follow-up. Vaginal erosion occured in 9 (9.3% patients, shrinkage of mesh in 6 (6.2% patients and de novo urinary incontinence in 5 (5.2% patients. Failure rate was 6.25% (recurrent prolapse stage 3 or 4 even asymptomatic. Conclusion. Our study suggests that transvaginal polypropylene mesh applied with a tensionfree technique is a safe and effective method with low intraoperative complications and low morbidity rates. However, some complications are serious and require highly specialised management.

  15. [Transvaginal mesh in repair of pelvic organs prolapse as a minimally invasive surgical procedure].

    Science.gov (United States)

    Argirović, Rajka; Berisavac, Milica; Likić-Ladević, Ivana; Kadija, Sasa; Bosković, Vladimir; Zizić, Vojislav

    2011-07-01

    Prolapse of genital organs with or without urinary stress incontinention is the most often health problem in the elderly female population tending to increase with ageing. The aim of this study was to assess the perioperative complications and short-term outcomes of prolaps repair using transvaginal polypropylene mesh (Prolift system, Gynecare, Ethicon, USA). A retrospective study was conducted evaluating 96 women from September 2006 to January 2010 who underwent vaginal repair with implatation of a soft mesh manufactured by Gynecare, Ethicon, USA. All the patients had a stage 3 or stage 4 prolapse according to the POP-Q system of ICS. Total mesh was used in 12 (13%) patients isolated anterior mesh in 52 (54%) patients and isolated posterior mesh in 32 (33%) patients. We reported one intra-operative bladder injury and no other serious complications. At 3 months, all 96 patients were available for follow-up. Vaginal erosion occured in 9 (9.3%) patients, shrinkage of mesh in 6 (6.2%) patients and de novo urinary incontinence in 5 (5.2%) patients. Failure rate was 6.25% (recurrent prolapse stage 3 or 4 even asymptomatic). Our study suggests that transvaginal polypropylene mesh applied with a tension-free technique is a safe and effective method with low intraoperative complications and low morbidity rates. However, some complications are serious and require highly specialised management.

  16. Vaginal Infections

    Science.gov (United States)

    ... gov/ Home Body Your reproductive health Vaginal infections Vaginal infections Help for infections If you have pain, ... infections and how to prevent them. Types of vaginal infections top Two common vaginal infections are bacterial ...

  17. Vaginal Atrophy

    Science.gov (United States)

    ... an Endocrinologist Search Featured Resource Menopause Map™ View Vaginal Atrophy October 2017 Download PDFs English Editors Christine ... during this time, including vaginal dryness. What is vaginal atrophy? Vaginal atrophy (also referred to as vulvovaginal ...

  18. Vaginal Atrophy

    Science.gov (United States)

    ... urinary signs and symptoms: Vaginal dryness Vaginal burning Vaginal discharge Genital itching Burning with urination Urgency with urination ... others). Also make an appointment if you have vaginal symptoms, such as unusual ... burning or soreness. Causes Genitourinary syndrome of menopause ( ...

  19. Actinomyces associated with persistent vaginal granulation tissue.

    OpenAIRE

    Wai, Clifford Y; Nihira, Mikio A; Drewes, Peter G; Chang, Joe S; Siddiqui, Momin T; Hemsell, David L

    2005-01-01

    BACKGROUND: We report a case of symptomatic actinomycosis associated with vaginal suture erosion and granulation tissue refractory to conservative management, in an outpatient setting. CASE: Three months after total vaginal hysterectomy and uterosacral ligament vaginal vault suspension, a woman complained of painless, intermittent vaginal discharge and spotting. Despite cauterization of granulation tissue, vaginal spotting persisted for another month. On re-examination, braided polyester sutu...

  20. Transvaginal repair of genital prolapse: preliminary results of a new tension-free vaginal mesh (Prolift technique)--a case series multicentric study.

    Science.gov (United States)

    Fatton, B; Amblard, J; Debodinance, P; Cosson, M; Jacquetin, B

    2007-07-01

    Our goal was to report the preliminary results of a transvaginal mesh repair of genital prolapse using the Prolift system. This retrospective multicentric study includes 110 patients. All patients had a stage 3 (at the hymen) or stage 4 (beyond the hymen) prolapse. Total mesh was used in 59 patients (53.6%), an isolated anterior mesh in 22 patients (20%) and an isolated posterior mesh in 29 patients (26.4%). We report one bladder injury sutured at surgery and two haematomas requiring secondary surgical management. At 3 months, 106 patients were available for follow-up. Mesh exposure occurred in five patients (4.7%), two of them requiring a surgical management. Granuloma without exposure occurred in three patients (2.8%). Failure rate (recurrent prolapse even asymptomatic or low grade symptomatic prolapse) was 4.7%. According to the perioperative and immediate post-operative results, Prolift repair seems to be a safe technique to correct pelvic organ prolapse. Anatomical and functional results must be assessed with a long-term follow-up to confirm the effectiveness and safety of the procedure.

  1. Mesh Excision: Is Total Mesh Excision Necessary?

    Science.gov (United States)

    Wolff, Gillian F; Winters, J Christian; Krlin, Ryan M

    2016-04-01

    Nearly 29% of women will undergo a secondary, repeat operation for pelvic organ prolapse (POP) symptom recurrence following a primary repair, as reported by Abbott et al. (Am J Obstet Gynecol 210:163.e1-163.e1, 2014). In efforts to decrease the rates of failure, graft materials have been utilized to augment transvaginal repairs. Following the success of using polypropylene mesh (PPM) for stress urinary incontinence (SUI), the use of PPM in the transvaginal repair of POP increased. However, in recent years, significant concerns have been raised about the safety of PPM mesh. Complications, some specific to mesh, such as exposures, erosion, dyspareunia, and pelvic pain, have been reported with increased frequency. In the current literature, there is not substantive evidence to suggest that PPM has intrinsic properties that warrant total mesh removal in the absence of complications. There are a number of complications that can occur after transvaginal mesh placement that do warrant surgical intervention after failure of conservative therapy. In aggregate, there are no high-quality controlled studies that clearly demonstrate that total mesh removal is consistently more likely to achieve pain reduction. In the cases of obstruction and erosion, it seems clear that definitive removal of the offending mesh is associated with resolution of symptoms in the majority of cases and reasonable practice. There are a number of complications that can occur with removal of mesh, and patients should be informed of this as they formulate a choice of treatment. We will review these considerations as we examine the clinical question of whether total versus partial removal of mesh is necessary for the resolution of complications following transvaginal mesh placement.

  2. Complications of Transvaginal Mesh for Pelvic Organ Prolapse and Stress Urinary Incontinence: Tips for Prevention, Recognition, and Management.

    Science.gov (United States)

    MacDonald, Susan; Terlecki, Ryan; Costantini, Elisabetta; Badlani, Gopal

    2016-08-01

    Mesh-related complications following transvaginal management of pelvic organ prolapse (POP) and/or stress urinary incontinence (SUI) have received significant attention in the last decade. We sought to identify patient, product, and technical factors associated with an increased risk of complications after mesh-based transvaginal repair of anterior POP and SUI. In this review we clarify the different pattern of complications after POP and SUI repairs. Our aim is to provide a practical evidence-based guide for physicians to prevent and, if necessary, manage product-associated complications in a stepwise manner. We conducted a comprehensive PubMed search of all English-language articles published from 2010 to June 2016, using these search terms: mesh, pelvic organ prolapse, and stress urinary incontinence. Expert opinion is also provided. Mesh-related complications are much lower after repair of SUI compared with POP, despite its more frequent use. Vaginal exposure is the most common mesh-specific complication. Patients may present with vaginal discharge, dyspareunia, pain, recurrent urinary tract infection, and/or hematuria. Conversely, patients may be asymptomatic. Small asymptomatic mesh exposures (mesh encountered within the urinary tract must be fully excised. Following excision, pain may persist in up to 50% of patients. Vaginal extrusion, persistent pain, and urethral and/or bladder erosion are the three most common product-specific complications following mesh-based repair for SUI or POP. Conservative therapies may be attempted, but most patients ultimately require partial or complete mesh excision. We reviewed the recent literature on mesh-related complications after repair of pelvic organ prolapse (POP) and stress urinary incontinence (SUI). Vaginal exposure, persistent pain, and erosion into the urinary tract are the most common. These often require surgical management, best suited to a urologist with training and experience in this area. Evidence supports

  3. Vaginal Odor

    Science.gov (United States)

    ... normally occurring vaginal bacteria — is the most common vaginal infection that causes a vaginal odor. Trichomoniasis — a sexually transmitted infection — also can lead to vaginal odor. Chlamydia and gonorrhea infections usually don't cause vaginal odors. Neither do ...

  4. Sacral colpopexy versus transvaginal mesh colpopexy in obese patients.

    Science.gov (United States)

    McDermott, Colleen D; Park, Jean; Terry, Colin L; Woodman, Patrick J; Hale, Douglass S

    2013-05-01

    Obesity can predispose women to pelvic organ prolapse and can also affect the success of pelvic organ prolapse surgery. The purpose of this study was to compare the postoperative anatomical outcomes following sacral colpopexy (SC) and transvaginal mesh colpopexy in a group of obese women with pelvic organ prolapse. We conducted a retrospective cohort study of obese women who underwent SC (n = 56) or transvaginal mesh colpopexy (n = 35). Follow-up ranged from 6 to 12 months. Preoperative, perioperative, and postoperative variables were compared using Student t, Mann-Whitney U, and Fisher exact tests, and by analysis of covariance. The women in the SC group had significantly higher mean apical vaginal measurements (P transvaginal mesh colpopexy group. There were no significant differences between the groups for other postoperative outcomes, including mesh erosion, recurrent prolapse symptoms, dyspareunia, and surgical satisfaction (P > 0.05). In these 91 obese patients with pelvic organ prolapse, SC resulted in better anatomical outcomes than transvaginal mesh colpopexy. However, the two procedures had similar outcomes with regard to recurrent symptoms and surgical satisfaction.

  5. Management of complications of mesh surgery.

    Science.gov (United States)

    Lee, Dominic; Zimmern, Philippe E

    2015-07-01

    Transvaginal placements of synthetic mid-urethral slings and vaginal meshes have largely superseded traditional tissue repairs in the current era because of presumed efficacy and ease of implant with device 'kits'. The use of synthetic material has generated novel complications including mesh extrusion, pelvic and vaginal pain and mesh contraction. In this review, our aim is to discuss the management, surgical techniques and outcomes associated with mesh removal. Recent publications have seen an increase in presentation of these mesh-related complications, and reports from multiple tertiary centers have suggested that not all patients benefit from surgical intervention. Although the true incidence of mesh complications is unknown, recent publications can serve to guide physicians and inform patients of the surgical outcomes from mesh-related complications. In addition, the literature highlights the growing need for a registry to account for a more accurate reporting of these events and to counsel patients on the risk and benefits before proceeding with mesh surgeries.

  6. Tension free monofilament macropore polypropylene mesh (Gynemesh PS in female genital prolapse repair

    Directory of Open Access Journals (Sweden)

    Vicente Sola

    2006-08-01

    Full Text Available OBJECTIVES: To review intraoperative and postoperative complications associated to the correction of cystocele and rectocele with polypropylene mesh macropore monofilament (Gynemesh PS using transvaginal free tension technique. MATERIALS AND METHODS: Prospective study of patients that have been submitted to correction of cystocele and/or rectocele between November 2004 and August 2005 in the Urogynecology and Vaginal Surgery Unit of Gynecology and Obstetrics Department, Las Condes Clinic. Mesh was used in 31 patients: 9 for cystocele, 11 for rectocele, and 11 for concomitant meshes. Total mesh used 42. Media age 55 years old, weight 64 kilograms. In 7 patients we used a third mesh for correction of urinary incontinence by TVT-O technique. RESULTS: They did not present intraoperative complications, neither in immediate or delayed postoperative time. We did not observe hematoma, infection, erosion or exposition mesh. Healing of cystocele and rectocele was obtained in 100% of patients, with a pursuit between 1 and 8 months. DISCUSSION: The use of prosthetic polypropylene monofilament macropore mesh in the correction of cystocele and/or rectocele, by transvaginal route with tension free technique seems to be a safe and effective surgery procedure.

  7. Opfront: mesh

    DEFF Research Database (Denmark)

    2015-01-01

    Mesh generation and visualization software based on the CGAL library. Folder content: drawmesh Visualize slices of the mesh (surface/volumetric) as wireframe on top of an image (3D). drawsurf Visualize surfaces of the mesh (surface/volumetric). img2mesh Convert isosurface in image to volumetric m...... mesh (medit format). img2off Convert isosurface in image to surface mesh (off format). off2mesh Convert surface mesh (off format) to volumetric mesh (medit format). reduce Crop and resize 3D and stacks of images. data Example data to test the library on...

  8. Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study.

    Science.gov (United States)

    ElSheemy, Mohammed S; Fathy, Hesham; Hussein, Hussein A; Elsergany, Ragheb; Hussein, Eman A

    2015-10-01

    The objective of the study was to compare the safety and efficacy of surgeon-tailored polypropylene mesh (STM) through tension-free vaginal tape-obturator (TVT-O) versus original TVT-O in the treatment of stress urinary incontinence (SUI) aiming to decrease the cost of treatment. This is important in developing countries due to limited health care resources. A retrospective cohort study was done at the Urology and Gynecology Departments (dual-center), Cairo University from May 2007 to June 2010. Women evaluated by cough stress test, Stress and Urge Incontinence and Quality of Life Questionnaire (SUIQQ), maximum flow rate (Qmax), and abdominal leak point pressure (ALPP) with follow-up for at least 48 months were included. Patients with post-void residual urine > 100 ml, bladder capacity TVT-O were inserted in 79 and 66 women, respectively. Intrinsic sphincter deficiency, ALPP, previous surgeries, associated urgency, urgency urinary incontinence (UUI), and prolapse were comparable in both groups. Operative duration was longer in STM by 10 min. No significant difference was found between both groups in complications (p = 0.462), cure (p = 0.654), and different indices of SUIQQ. In STM, 74 (93 %) were cured and 3 (4 %) improved, while SUI persisted in 2 (2 %) patients. In TVT-O, 59 (89 %) were cured and 4 (6 %) improved, while failure was detected in 3 (4 %) patients. The 5-year outcome is comparable between STM and TVT-O. Furthermore, STM is more economical due to our resterilizable modified helical passers and the cheap polypropylene mesh.

  9. Vaginal disorders.

    Science.gov (United States)

    Soderberg, S F

    1986-05-01

    Chronic vaginitis is the most common vaginal disorder. Dogs with vaginitis show no signs of systemic illness but often lick at the vulva and have purulent or hemorrhagic vaginal discharges. Vaginitis is most commonly secondary to a noninfectious inciting factor such as congenital vaginal anomalies, clitoral hypertrophy, foreign bodies, trauma to the vaginal mucosa, or vaginal tumors. Inspection of the caudal vagina and vestibule both visually and digitally will often reveal the source of vaginal irritation. Vaginal cytology is used to establish the stage of the estrous cycle as well as distinguish uterine from vaginal sources of discharge. Vaginal cultures are used to establish the predominant offending organism associated with vaginal discharges and may be used as a guide for selection of a therapeutic agent. Vaginitis is best managed by removing the inciting cause and treating the area locally with antiseptic douches. Congenital malformations at the vestibulovaginal or vestibulovulvar junction may prevent normal intromission. Affected bitches may be reluctant to breed naturally because of pain. Such defects are detected best by digital examination. Congenital vaginal defects may be corrected by digital or surgical means. Prolapse of tissue through the lips of the vulva may be caused by clitoral hypertrophy, vaginal hyperplasia, or vaginal tumors. Enlargement of clitoral tissue is the result of endogenous or exogenous sources of androgens. Treatment of this condition includes removal of the androgen source and/or surgical removal of clitoral tissue. Vaginal hyperplasia is detected during proestrus or estrus of young bitches. Hyperplastic tissue will regress during diestrus. Tissue that is excessively traumatized and/or prolapse of the entire vaginal circumference may be removed surgically. Ovariohysterectomy may be used to prevent recurrence. Vaginal tumors are detected most often in older intact bitches. Such tumors are generally of smooth muscle or fibrous

  10. Vaginal cysts

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001509.htm Vaginal cysts To use the sharing features on this ... with air, fluid, pus, or other material. A vaginal cyst occurs on or under the lining of ...

  11. Vaginal Diseases

    Science.gov (United States)

    Vaginal problems are some of the most common reasons women go to the doctor. They may have ... common problem is vaginitis, an inflammation of the vagina. Other problems that affect the vagina include sexually ...

  12. Transvaginal Resection of an Infected Sacrocolpopexy Mesh by Single-Port Trocar.

    Science.gov (United States)

    Schaub, Marie; Lecointre, Lise; Faller, Emilie; Boisramé, Thomas; Baldauf, Jean-Jacques; Akladios, Cherif Youssef

    Laparoscopy using a single port improves morbidity while keeping the same level of requirement. This technique has been evaluated in gynecology for salpingectomy, ovarian surgery, and hysterectomy. Here, the authors illustrate a new use of a single port using the transvaginal approach. Case report (Canadian Task Force classification III). Tertiary referral center in Strasbourg, France. Woman age 59 years. Single-port platform used in the transvaginal approach for resection of sacrocolpopexy mesh. The local institutional review board approved the video. A 59-year-old woman suffering from insulin-dependent diabetes and a tobacco user had 2 laparoscopic sacrocolpopexies for recurrent rectocele, the first in 2007 and the second in 2012. The sequences were marked by mesh erosion and granuloma in the vagina, requiring its surgical excision in 2016. The patient was then symptomatic, with an increasingly foul-smelling vaginal discharge with recurrent mesh erosion. Magnetic resonance imaging showed an abscess formation along the length of the mesh to the promontory. The patient then underwent surgery, realized under probabilistic antibiotic therapy, consisting of complete excision of the sacrocolpopexy mesh by the transvaginal approach. After putting the single-port trocar (GelPoint; Applied Medical, Rancho Santa Margarita, CA) into the vagina and obtaining distension with the insufflator (AirSeal; Conmed, Utica, NY), classic laparoscopic instruments were introduced by the single-port trocar. The mesh was entirely resected in the retroperitoneal space. Mesh was again used because the exposed space is almost always surrounded by loose granulation tissue that facilitates dissection and also prevents injury to adjacent structures such as bladder, rectum, and peritoneum. Moreover, the opening of adjacent structures will manifest gas leaks and, consequently, loss of the pneumovagina. At the end of procedure, the vagina is not closed to permit optimal drainage with a multitubular

  13. Intraoperative Ultrasound-Guided Removal of Retained Mini Sling Anchor Causing Vaginal Pain: A Case Report.

    Science.gov (United States)

    Almassi, Nima; Goldman, Howard B

    2016-01-01

    Since the introduction of the tension-free vaginal tape, the surgical management of female stress urinary incontinence has undergone a dramatic shift toward synthetic midurethral slings (MUSs). The evolution of the MUS has led to the development of the single incision mini sling (SIMS), a minimally invasive procedure that can be performed under local anesthesia. Complications arising after SIMS placement parallel those of the traditional MUS, including pelvic pain, dyspareunia, and mesh erosion. The patient in this case presented with persistent pelvic pain due to a retained SIMS anchor after having previously undergone SIMS placement and subsequent transvaginal exploration with mesh removal. We report the use of intraoperative ultrasound for identification and removal of the retained SIMS anchor.

  14. Laparoscopic mesh explantation and drainage of sacral abscess remote from transvaginal excision of exposed sacral colpopexy mesh.

    Science.gov (United States)

    Roth, Ted M; Reight, Ian

    2012-07-01

    Sacral colpopexy may be complicated by mesh exposure, and the surgical treatment of mesh exposure typically results in minor postoperative morbidity and few delayed complications. A 75-year-old woman presented 7 years after a laparoscopic sacral colpopexy, with Mersilene mesh, with an apical mesh exposure. She underwent an uncomplicated transvaginal excision and was asymptomatic until 8 months later when she presented with vaginal drainage and a sacral abscess. This was successfully treated with laparoscopic enterolysis, drainage of the abscess, and explantation of the remaining mesh. Incomplete excision of exposed colpopexy mesh can lead to ascending infection and sacral abscess. Laparoscopic drainage and mesh removal may be considered in these patients.

  15. Postoperative pain outcomes after transvaginal mesh revision.

    Science.gov (United States)

    Danford, Jill M; Osborn, David J; Reynolds, W Stuart; Biller, Daniel H; Dmochowski, Roger R

    2015-01-01

    Although the current literature discusses mesh complications including pain, as well as suggesting different techniques for removing mesh, there is little literature regarding pain outcomes after surgical removal or revision. The purpose of this study is to determine if surgical removal or revision of vaginal mesh improves patient's subjective complaints of pelvic pain associated with original placement of mesh. After obtaining approval from the Vanderbilt University Medical Center Institutional Review Board, a retrospective review of female patients with pain secondary to previous mesh placement who underwent excision or revision of vaginal mesh from January 2000 to August 2012 was performed. Patient age, relevant medical history including menopause status, previous hysterectomy, smoking status, and presence of diabetes, fibromyalgia, interstitial cystitis, and chronic pelvic pain, was obtained. Patients' postoperative pain complaints were assessed. Of the 481 patients who underwent surgery for mesh revision, removal or urethrolysis, 233 patients met our inclusion criteria. One hundred and sixty-nine patients (73 %) reported that their pain improved, 19 (8 %) reported that their pain worsened, and 45 (19 %) reported that their pain remained unchanged after surgery. Prior history of chronic pelvic pain was associated with increased risk of failure of the procedure to relieve pain (OR 0.28, 95 % CI 0.12-0.64, p = 0.003). Excision or revision of vaginal mesh appears to be effective in improving patients' pain symptoms most of the time. Patients with a history of chronic pelvic pain are at an increased risk of no improvement or of worsening pain.

  16. Vaginal Cancer

    Science.gov (United States)

    Vaginal cancer is a rare type of cancer. It is more common in women 60 and older. You are also more likely to get it if you have had a human ... test can find abnormal cells that may be cancer. Vaginal cancer can often be cured in its ...

  17. Vaginal Fistula

    Science.gov (United States)

    Vaginal fistula Overview A vaginal fistula is an abnormal opening that connects your vagina to another organ, such as your bladder, colon or rectum. Your ... describe the condition as a hole in your vagina that allows stool or urine to pass through ...

  18. Management of complications arising from transvaginal mesh kit procedures: a tertiary referral center's experience.

    Science.gov (United States)

    Hurtado, Eric A; Appell, Rodney A

    2009-01-01

    This case series' purpose is to review a referral center's experience with complications from mesh kits. A chart review of 12 patients who presented with complications associated with transvaginal mesh kit procedures was performed. All patients underwent complete surgical removal of the mesh to treat mesh exposure, pain, or vaginal bleeding/discharge followed by an anterior or posterior repair. The mean follow-up time after surgery was 3.4 months. Eight of 12 patients had mesh that had formed a fibrotic band. Six of 12 patients had complete resolution of pain. Of the nine patients with mesh exposure, all required significant resection of the vaginal wall. No further mesh exposure occurred. The use of transvaginal mesh kits may cause previously undescribed complications such as pelvic/vaginal pain or large extrusions requiring complete removal. Removal of all mesh except the arms may cure or significantly improve these problems.

  19. Vaginal Bleeding

    Science.gov (United States)

    ... or period, is a woman's monthly bleeding.Abnormal vaginal bleeding is different from normal menstrual periods. It ... therapy) Cancer of the cervix, ovaries, uterus or vagina Thyroid problems Bleeding during pregnancy can have several ...

  20. Estrogen Vaginal

    Science.gov (United States)

    ... menopause (change of life; the end of monthly menstrual periods). Femring® brand estradiol vaginal ring is also ... applicator. Ask your pharmacist or doctor for a copy of the manufacturer's information for the patient.

  1. Vaginal cancer

    Science.gov (United States)

    Hacker NF. Vulvar and vaginal cancer. In: Hacker NF, Gambone JC, Hobel CJ, eds. Hacker and Moore's Essentials of Obstetrics and Gynecology . 6th ed. Philadelphia, PA: Elsevier; 2016:chap 40. Jhingran ...

  2. Vaginal reconstruction

    International Nuclear Information System (INIS)

    Lesavoy, M.A.

    1985-01-01

    Vaginal reconstruction can be an uncomplicated and straightforward procedure when attention to detail is maintained. The Abbe-McIndoe procedure of lining the neovaginal canal with split-thickness skin grafts has become standard. The use of the inflatable Heyer-Schulte vaginal stent provides comfort to the patient and ease to the surgeon in maintaining approximation of the skin graft. For large vaginal and perineal defects, myocutaneous flaps such as the gracilis island have been extremely useful for correction of radiation-damaged tissue of the perineum or for the reconstruction of large ablative defects. Minimal morbidity and scarring ensue because the donor site can be closed primarily. With all vaginal reconstruction, a compliant patient is a necessity. The patient must wear a vaginal obturator for a minimum of 3 to 6 months postoperatively and is encouraged to use intercourse as an excellent obturator. In general, vaginal reconstruction can be an extremely gratifying procedure for both the functional and emotional well-being of patients

  3. Vaginal Microbiota.

    Science.gov (United States)

    Mendling, Werner

    2016-01-01

    The knowledge about the normal and abnormal vaginal microbiome has changed over the last years. Culturing techniques are not suitable any more for determination of a normal or abnormal vaginal microbiota. Non culture-based modern technologies revealed a complex and dynamic system mainly dominated by lactobacilli.The normal and the abnormal vaginal microbiota are complex ecosystems of more than 200 bacterial species influenced by genes, ethnic background and environmental and behavioral factors. Several species of lactobacilli per individuum dominate the healthy vagina. They support a defense system together with antibacterial substances, cytokines, defensins and others against dysbiosis, infections and care for an normal pregnancy without preterm birth.The numbers of Lactobacillus (L.) iners increase in the case of dysbiosis.Bacterial vaginosis (BV) - associated bacteria (BVAB), Atopobium vaginae and Clostridiales and one or two of four Gardnerella vaginalis - strains develop in different mixtures and numbers polymicrobial biofilms on the vaginal epithelium, which are not dissolved by antibiotic therapies according to guidelines and, thus, provoke recurrences.Aerobic vaginitis seems to be an immunological disorder of the vagina with influence on the microbiota, which is here dominated by aerobic bacteria (Streptococcus agalactiae, Escherichia coli). Their role in AV is unknown.Vaginal or oral application of lactobacilli is obviously able to improve therapeutic results of BV and dysbiosis.

  4. Hysterectomy - vaginal - discharge

    Science.gov (United States)

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  5. Current situation of transvaginal mesh repair for pelvic organ prolapse.

    Science.gov (United States)

    Zhu, Lan; Zhang, Lei

    2014-09-01

    Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Surgical mesh has been used since the 1950s to repair abdominal hernias. In the 1970s, gynecologists began using surgical mesh products to indicate the repair of pelvic organ prolapse (POP), and in the 1990s, gynecologists began using surgical mesh for POP. Then the U.S. Food and Drug Administration (FDA) approved the first surgical mesh product specifically for use in POP. Surgical mesh materials can be divided into several categories. Most surgical mesh devices cleared for POP procedures are composed of non-absorbable synthetic polypropylene. Mesh can be placed in the anterior vaginal wall to aid in the correction of cystocele (anterior repair), in the posterior vaginal wall to aid in correction of rectocele (posterior repair), or attached to the top of the vagina to correct uterine prolapse or vaginal apical prolapse (apical repair). Over the past decades, surgical mesh products for transvaginal POP repair became incorporated into "kits" that included tools to aid in the delivery and insertion of the mesh. Surgical mesh kits continue to evolve, adding new insertion tools, tissue fixation anchors, surgical techniques, and ab- sorbable and biological materials. This procedure has been performed popularly. It was also performed increased in China. But this new technique met some trouble recently and let shake in urogynecology.

  6. Runoff erosion

    OpenAIRE

    Evelpidou, Niki (Ed.); Cordier, Stephane (Ed.); Merino, Agustin (Ed.); Figueiredo, Tomás de (Ed.); Centeri, Csaba (Ed.)

    2013-01-01

    Table of Contents PART I – THEORY OF RUNOFF EROSION CHAPTER 1 - RUNOFF EROSION – THE MECHANISMS CHAPTER 2 - LARGE SCALE APPROACHES OF RUNOFF EROSION CHAPTER 3 - MEASURING PRESENT RUNOFF EROSION CHAPTER 4 - MODELLING RUNOFF EROSION CHAPTER 5 - RUNOFF EROSION AND HUMAN SOCIETIES: THE INFLUENCE OF LAND USE AND MANAGEMENT PRACTICES ON SOIL EROSION PART II - CASE STUDIES CASE STUDIES – INTRODUCTION: RUNOFF EROSION IN MEDITERRANEAN AREA CASE STUDY 1: Soil Erosion Risk...

  7. Assisted Vaginal Delivery

    Science.gov (United States)

    ... Education & Events Advocacy For Patients About ACOG Assisted Vaginal Delivery Home For Patients Search FAQs Assisted Vaginal ... Vaginal Delivery FAQ192, February 2016 PDF Format Assisted Vaginal Delivery Labor, Delivery, and Postpartum Care What is ...

  8. [Three years results of transvaginal cystocele repair with polypropylene mesh using a tension-free technique].

    Science.gov (United States)

    El Harrech, Y; Ameur, A; Janane, A; Moufide, K; Ghadouane, M; Abbar, M

    2010-01-01

    To evaluate the long term efficacy and safety of transvaginal implantation of a non-resorbable synthetic prosthesis (Gynemesh) for the treatment of cystocele using transvaginal free tension technique. Prospective study of patients that have been submitted to correction of cystocele between April 2004 and July 2007. A prolene mesh was cut to an appropriate size to cover the whole cystocele leaving two tabs on each side. The two tabs of the mesh were then placed in paravaginal spaces, tension free, without stitches. Mesh was used in 31 patients. All patients had a symptomatic cystocele >or= 2 according to Baden-Walker halfway classification. Patients were reviewed initially at 1 and 3 month and then every 6 months. The mean age of the patients was 58 years (range: 47-70 years). Mean parity was 5.8 (range 1-11), and mean weight was 75 kg (range 60-82Kg). All women were postmenopausal. The operation was combined with vaginal hysterectomy in 2 patients, Posterior colporraphy in 2 patients, Perineorrhaphy in 1 patient, Sacrospinous fixation in 2 patients, transobturator tape for stress urinary incontinence in 7 women. Average time of surgery was 23 minutes for cystocele. There were no major complications, such as trauma to the bladder, urethra, bowels, or large vessels in the patient group treated. There was no immediate postoperative complications (up to 7 days) recorded. No hematoma or infection was observed in the operative area. Mesh erosion was detected in one patient. It was treated by excision of the eroded part of the mesh. Mean follow-up was 36.4 months (18 to 52 months). Using our definition of success based on both anatomic and functional outcomes, the overall cure rate was 74.19% (asymptomatic with no or grade 1 cystocele). The improvement rate (asymptomatic with a grade 2 cystocele) was 19.35% and the overall failure rate (symptomatic or with a grade 3 or 4 cystocele) was only 6.4% (2 women). The interposition of a sub-vesical transversal tension

  9. Erosive Lichen Planus.

    Science.gov (United States)

    Mauskar, Melissa

    2017-09-01

    Lichen planus is an inflammatory mucocutaneous condition with a myriad of clinical manifestations. There are 3 forms of lichen planus that effect the vulva: papulosquamous, hypertrophic, and erosive. Erosive lichen planus can progress to vulvar scaring, vaginal stenosis, and squamous cell carcinoma; these long-term sequelae cause sexual distress, depression, and decreased quality of life for patients. Diagnosis is often delayed because of patient embarrassment or clinician misdiagnosis. Early recognition and treatment is essential to decreasing the morbidity of this condition. Multimodal treatment, along with a multidisciplinary approach, will improve outcomes and further clinical advances in studying this condition. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Evaluation of a transvaginal mesh delivery system for the correction of pelvic organ prolapse: subjective and objective findings at least 1 year after surgery.

    Science.gov (United States)

    Culligan, Patrick J; Littman, Paul M; Salamon, Charbel G; Priestley, Jennifer L; Shariati, Amir

    2010-11-01

    We sought to track objective and subjective outcomes ≥1 year after transvaginal mesh system to correct prolapse. This was a retrospective cohort study of 120 women who received a transvaginal mesh procedure (Avaulta Solo, CR Bard Inc, Covington, GA). Outcomes were pelvic organ prolapse quantification values; Pelvic Floor Distress Inventory, Short Form 20/Pelvic Floor Impact Questionnaire, Short Form 7 scores; and a surgical satisfaction survey. "Surgical failure" was defined as pelvic organ prolapse quantification point >0, and/or any reports of vaginal bulge. Of 120 patients, 116 (97%) were followed up for a mean of 14.4 months (range, 12-30). In all, 74 patients had only anterior mesh, 21 only posterior mesh, and 21 both meshes. Surgical cure rate was 81%. Surgical failure was more common if preoperative point C ≥+2 (35% vs 16%; P = .04). Mesh erosion and de novo pain occurred in 11.7% and 3.3%, respectively. Pelvic Floor Distress Inventory, Short Form 20/Pelvic Floor Impact Questionnaire, Short Form 7 scores improved (P < .01). Objective and subjective improvements occurred at ≥1 year, yet failure rates were high when preoperative point C was ≥+2. Copyright © 2010 Mosby, Inc. All rights reserved.

  11. Anterior vaginal prolapse repair: A randomised trial of traditional ...

    African Journals Online (AJOL)

    Women with symptomatic anterior vaginal prolapse ≥POPQ stage II were included. Those with concomitant stress urinary ... ation, erosion, bleeding and discharge, pain and dyspareunia.[9] The .... which is similar to reports in other studies.

  12. Vaginally-Assisted Laparoscopic Hysterosacropexy for Advanced Utero-Vaginal Prolapse: A Series of 32 Cases

    Directory of Open Access Journals (Sweden)

    Elvira Brătilă V.

    2014-05-01

    Full Text Available Advanced utero-vaginal prolapse is a frequent condition in the aging female population and several strategies aimed at its treatment have been developed. In order to demonstrate the importance of using the vaginal route in assistance to laparoscopic hysterosacropexy, a retrospective case series was designed, comparing thirty-two patients diagnosed with stage III-IV uterovaginal prolapse according to the POP-Q system. The patients were treated between 2006-2011 using one of two methods of hysterosacropexy: vaginally assisted laparoscopic hysterosacropexy (VALHS in 18 cases and total laparoscopic hysterosacropexy (LHS in 14 cases. The choice of method was based on the primary mechanism of central compartment prolapse. The total operative time, the time required for mesh fixation at the cervix and sacrum, the cure rate of prolapse and the rate of re-operation for prolapse were statistically analyzed for both LHS and VALHS and compared between these two procedures by Student T-Test. The main outcome parameters were related to the operative method. The total operative time proved to be equal for both procedures, although the time necessary to attach the mesh to the cervical ring was shorter in VALHS. Therefore, the combination of the vaginal and laparoscopic routes yields a minimally invasive variant of sacropexy with as short an operative time as possible. The vaginal route offers a safe alternative for suturing the mesh and treating concurrent vaginal wall prolapse, while laparoscopy reduces the inherent risks of open abdominal surgery.

  13. Long-term follow-up of treatment for synthetic mesh complications.

    Science.gov (United States)

    Hansen, Brooke L; Dunn, Guinn Ellen; Norton, Peggy; Hsu, Yvonne; Nygaard, Ingrid

    2014-01-01

    The objectives of this study are (1) to describe the presenting symptoms, findings, and treatment and (2) to describe the self-reported improvement and function at least 6 months after presentation in women presenting to 1 urogynecology division for complications associated with synthetic vaginal mesh. Women evaluated between 2006 and 2011 were identified by diagnostic codes. We abstracted information from the medical record and attempted to contact all women to complete a follow-up telephone survey questionnaire consisting of several validated instruments. A total of 111 women were evaluated for complications associated with synthetic vaginal mesh. The mean interval from index surgery was 2.4 years. Of these, 84% were referred from outside hospitals. Index surgeries included vaginal mesh kits/vaginally placed mesh (47%), midurethral mesh slings (37%), abdominally placed vaginal mesh (11%), and vaginal mesh kit with concomitantly placed mesh sling (5%). The most common complications were extrusion (65%), contraction (17%), and chronic pelvic pain (16%). A total of 98 women underwent some type of treatment (85 surgical) by urogynecologists, pelvic pain specialists, or physical therapists. Eighty-four (76%) provided follow-up information at mean interval since presentation of 2.3 years. At follow-up, the mean (SD) Pelvic Floor Distress Inventory score was 98 (67), the mean (SD) EQ-5D index score was 0.69 (0.23), and 22% reported vaginal discharge, 15% vaginal bleeding or spotting, and 45% sexual abstinence due to problems related to mesh. A total of 71% reported being overall better, whereas 29% were the same or worse. Two years after tertiary care level multidisciplinary treatment of vaginal mesh complications, many women still report symptoms that negatively impact their quality of life.

  14. Urogynecologic Surgical Mesh Implants

    Science.gov (United States)

    ... procedures performed to treat pelvic floor disorders with surgical mesh: Transvaginal mesh to treat POP Transabdominal mesh to treat ... address safety risks Final Order for Reclassification of Surgical Mesh for Transvaginal Pelvic Organ Prolapse Repair Final Order for Effective ...

  15. Vaginal sponge and spermicides

    Science.gov (United States)

    ... counter; Contraceptives - over the counter; Family planning - vaginal sponge; Contraception - vaginal sponge ... Spermicides and vaginal sponges do not work as well at preventing pregnancy as some other forms of birth control. However, using a spermicide ...

  16. Vaginal bleeding in pregnancy

    Science.gov (United States)

    Pregnancy - vaginal bleeding; Maternal blood loss - vaginal ... Up to 1 in 4 women have vaginal bleeding at some time during their pregnancy. Bleeding is more common in the first 3 months (first trimester), especially with twins.

  17. Vaginal yeast infection

    Science.gov (United States)

    Yeast infection - vagina; Vaginal candidiasis; Monilial vaginitis ... Most women have a vaginal yeast infection at some time. Candida albicans is a common type of fungus. It is often found in small amounts ...

  18. A Comparison of the Incidence of Early Postoperative Infections between Patients Using Synthetic Mesh and Those Undergoing Traditional Pelvic Reconstructive Surgical Procedures

    Directory of Open Access Journals (Sweden)

    Jaromír Mašata

    2013-01-01

    Full Text Available New mesh-related complications such as erosion, etc., can result from abnormal postoperative healing due to surgical site infection. The aim of our study was to compare systemic inflammatory responses and the incidence of early infectious complications after reconstructive surgery using synthetic mesh and after traditional vaginal wall repair. In this prospective observational study 99 women with symptomatic pelvic organ prolapse were included; 55 women underwent traditional repair and 44 repair using mesh. After the procedure infectious complications were monitored. The patients who underwent reconstructive surgery using mesh material were more likely to have febrile morbidity in the postoperative period than the patients who had been treated with traditional repair (p=0.031; there was a higher incidence of combination febrile morbidity with elevated C-reactive protein (CRP > 50 mg/l; p=0.046, and a higher incidence of CRP increase over 30 mg/l; p=0.005. Reconstructive procedures using synthetic mesh are accompanied by a higher incidence of early post-operative infectious complications.

  19. MRI of vaginal conditions

    International Nuclear Information System (INIS)

    Lopez, C.; Balogun, M.; Ganesan, R.; Olliff, J.F.

    2005-01-01

    Magnetic resonance imaging (MRI) has become an important part of the assessment of suspected vaginal pathology. This pictorial review demonstrates the MRI features and some of the histopathological findings of a variety of vaginal conditions. These may be congenital (total vaginal agenesis, partial vaginal agenesis, longitudinal vaginal septum, transverse vaginal septum), benign (Bartholin's cyst, diffuse vaginal inflammation, invasive endometriosis, ureterovaginal fistula, post-surgical appearances with the formation of a neovagina and adhesions) or malignant, usually due to extension or recurrence from another pelvic malignancy. In this paper, examples of the above are described and illustrated together with examples of the much rarer primary vaginal malignancies

  20. MRI of vaginal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, C. [Department of Radiology, Birmingham Women' s Hospital, Birmingham (United Kingdom)]. E-mail: carolina.lopez@bwhct.nhs.uk; Balogun, M. [Department of Radiology, Birmingham Women' s Hospital, Birmingham (United Kingdom); Ganesan, R. [Department of Histopathology, Birmingham Women' s Hospital, Birmingham (United Kingdom); Olliff, J.F. [University Hospital Birmingham, Birmingham (United Kingdom)

    2005-06-01

    Magnetic resonance imaging (MRI) has become an important part of the assessment of suspected vaginal pathology. This pictorial review demonstrates the MRI features and some of the histopathological findings of a variety of vaginal conditions. These may be congenital (total vaginal agenesis, partial vaginal agenesis, longitudinal vaginal septum, transverse vaginal septum), benign (Bartholin's cyst, diffuse vaginal inflammation, invasive endometriosis, ureterovaginal fistula, post-surgical appearances with the formation of a neovagina and adhesions) or malignant, usually due to extension or recurrence from another pelvic malignancy. In this paper, examples of the above are described and illustrated together with examples of the much rarer primary vaginal malignancies.

  1. Persistent pelvic pain following transvaginal mesh surgery: a cause for mesh removal.

    Science.gov (United States)

    Marcus-Braun, Naama; Bourret, Antoine; von Theobald, Peter

    2012-06-01

    Persistent pelvic pain after vaginal mesh surgery is an uncommon but serious complication that greatly affects women's quality of life. Our aim was to evaluate various procedures for mesh removal performed at a tertiary referral center in cases of persistent pelvic pain, and to evaluate the ensuing complications and outcomes. A retrospective study was conducted at the University Hospital of Caen, France, including all patients treated for removal or section of vaginal mesh due to pelvic pain as a primary cause, between January 2004 and September 2009. Ten patients met the inclusion criteria. Patients were diagnosed between 10 months and 3 years after their primary operation. Eight cases followed suburethral sling procedures and two followed mesh surgery for pelvic organ prolapse. Patients presented with obturator neuralgia (6), pudendal neuralgia (2), dyspareunia (1), and non-specific pain (1). The surgical treatment to release the mesh included: three cases of extra-peritoneal laparoscopy, four cases of complete vaginal mesh removal, one case of partial mesh removal and two cases of section of the suburethral sling. In all patients with obturator neuralgia, symptoms were resolved or improved, whereas in both cases of pudendal neuralgia the symptoms continued. There were no intra-operative complications. Post-operative Retzius hematoma was observed in one patient after laparoscopy. Mesh removal in a tertiary center is a safe procedure, necessary in some cases of persistent pelvic pain. Obturator neuralgia seems to be easier to treat than pudendal neuralgia. Early diagnosis is the key to success in prevention of chronic disease. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Erosion and erosion-corrosion

    International Nuclear Information System (INIS)

    Isomoto, Yoshinori

    2008-01-01

    It is very difficult to interpret the technical term of erosion-corrosion' which is sometimes encountered in piping systems of power plants, because of complicated mechanisms and several confusing definitions of erosion-corrosion phenomena. 'FAC (flow accelerated corrosion)' is recently introduced as wall thinning of materials in power plant systems, as a representative of 'erosion-corrosion'. FAC is, however, not necessarily well understood and compared with erosion-corrosion. This paper describes firstly the origin, definition and fundamental understandings of erosion and erosion-corrosion, in order to reconsider and reconfirm the phenomena of erosion, erosion-corrosion and FAC. Next, typical mapping of erosion, corrosion, erosion-corrosion and FAC are introduced in flow velocity and environmental corrosiveness axes. The concept of damage rate in erosion-corrosion is finally discussed, connecting dissolution rate, mass transfer of metal ions in a metal oxide film and film growth. (author)

  3. Vaginal Cancer Overview

    Science.gov (United States)

    ... are here Home > Types of Cancer > Vaginal Cancer Vaginal Cancer This is Cancer.Net’s Guide to Vaginal Cancer. Use the menu below to choose the ... social workers, and patient advocates. Cancer.Net Guide Vaginal Cancer Introduction Statistics Medical Illustrations Risk Factors and ...

  4. Management of vaginal extrusion after tension-free vaginal tape procedure for urodynamic stress incontinence.

    Science.gov (United States)

    Giri, Subhasis K; Sil, Debasri; Narasimhulu, Girish; Flood, Hugh D; Skehan, Mark; Drumm, John

    2007-06-01

    To report our experience in the management of vaginal extrusion after the tension-free vaginal tape (TVT) procedure for urodynamic stress incontinence. Five patients diagnosed with vaginal extrusion after a TVT procedure performed at our institution were identified. We reviewed the patients' records retrospectively. The interval from TVT placement to diagnosis, presenting symptoms and signs, duration of symptoms, diagnostic test findings, treatment, and postoperative results were recorded. Patients were followed up for at least 12 months. From January 2001 to June 2004, a total of 166 patients underwent the TVT procedure. Of these, 5 patients (3%) were diagnosed with isolated vaginal extrusion 4 to 40 months postoperatively. No cases of urethral or bladder erosion occurred in this series. The symptoms included vaginal discharge, pain, bleeding, and dyspareunia. The eroded margin of the vaginal mucosa was trimmed, mobilized, and closed over the tape with interrupted vertical mattress sutures in a single layer using 2-0 polyglactin 910 to avoid mucosal inversion. All patients remained symptom free without any evidence of defective healing or additional extrusion at a minimal follow-up of 12 months. Primary reclosure of the vaginal mucosa over the TVT tape is an effective first-line treatment option for vaginal extrusion without compromising continence. Patients undergoing the TVT procedure should be adequately counseled about the possibility of this complication and the available treatment options.

  5. Seeking new surgical predictors of mesh exposure after transvaginal mesh repair.

    Science.gov (United States)

    Wu, Pei-Ying; Chang, Chih-Hung; Shen, Meng-Ru; Chou, Cheng-Yang; Yang, Yi-Ching; Huang, Yu-Fang

    2016-10-01

    The purpose of this study was to explore new preventable risk factors for mesh exposure. A retrospective review of 92 consecutive patients treated with transvaginal mesh (TVM) in the urogynecological unit of our university hospital. An analysis of perioperative predictors was conducted in patients after vaginal repairs using a type 1 mesh. Mesh complications were recorded according to International Urogynecological Association (IUGA) definitions. Mesh-exposure-free durations were calculated by using the Kaplan-Meier method and compared between different closure techniques using log-rank test. Hazard ratios (HR) of predictors for mesh exposure were estimated by univariate and multivariate analyses using Cox proportional hazards regression models. The median surveillance interval was 24.1 months. Two late occurrences were found beyond 1 year post operation. No statistically significant correlation was observed between mesh exposure and concomitant hysterectomy. Exposure risks were significantly higher in patients with interrupted whole-layer closure in univariate analysis. In the multivariate analysis, hematoma [HR 5.42, 95 % confidence interval (CI) 1.26-23.35, P = 0.024), Prolift mesh (HR 5.52, 95 % CI 1.15-26.53, P = 0.033), and interrupted whole-layer closure (HR 7.02, 95 % CI 1.62-30.53, P = 0.009) were the strongest predictors of mesh exposure. Findings indicate the risks of mesh exposure and reoperation may be prevented by avoiding hematoma, large amount of mesh, or interrupted whole-layer closure in TVM surgeries. If these risk factors are prevented, hysterectomy may not be a relative contraindication for TVM use. We also provide evidence regarding mesh exposure and the necessity for more than 1 year of follow-up and preoperative counselling.

  6. Obturator foramen dissection for excision of symptomatic transobturator mesh.

    Science.gov (United States)

    Reynolds, W Stuart; Kit, Laura Chang; Kaufman, Melissa R; Karram, Mickey; Bales, Gregory T; Dmochowski, Roger R

    2012-05-01

    Groin pain after transobturator synthetic mesh placement can be recalcitrant to conservative therapy and ultimately requires surgical excision. We describe our experiences with and technique of obturator foramen dissection for mesh excision. The records of 8 patients treated from 2005 to 2010, were reviewed. Obturator dissection was performed via a lateral groin incision over the inferior pubic ramus at the level of the obturator foramen, typically in conjunction with orthopedic surgery. Five patients had transobturator mid urethral sling surgery for stress urinary incontinence, 2 had mid urethral sling and trocar based anterior vaginal wall mesh kits with transobturator passage of mesh arms for stress urinary incontinence and pelvic organ prolapse, and 1 had an anterior vaginal wall mesh kit for pelvic organ prolapse. Patients had 0 to 2 prior transvaginal mesh excisions before obturator surgery. All patients presented with intractable pain in the area of the obturator foramen and/or medial groin for which conservative treatment measures had failed. Six patients underwent concurrent vaginal and obturator dissection and 2 underwent obturator dissection alone. In all cases residual mesh (3 to 11 cm) was identified and excised from the obturator foramen. Mesh was closely associated to or traversing the adductor longus muscle and tendon with significant fibrous reaction in all cases. Postoperatively 5 patients were cured of pain and/or infection, and 3 reported no or some improvement at a mean followup of 6 months (range 1 to 12). Our experience suggests that surgical excision of residual mesh can alleviate many of the symptoms in many patients. In all cases mesh remnants were identified and removed, and typically involved neuromuscular structures adjacent to the obturator foramen. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. The mesh controversy [version 1; referees: 2 approved

    OpenAIRE

    Joshua A. Cohn; Elizabeth Timbrook Brown; Casey G. Kowalik; Melissa R. Kaufmann; Roger R. Dmochowski; W. Stuart Reynolds

    2016-01-01

    Pelvic organ prolapse and stress urinary incontinence are common conditions for which approximately 11% of women will undergo surgical intervention in their lifetime. The use of vaginal mesh for pelvic organ prolapse and stress urinary incontinence rose rapidly in the early 2000s as over 100 mesh products were introduced into the clinical armamentarium with little regulatory oversight for their use. US Food and Drug Administration Public Health Notifications in 2008 and 2011, as well as recla...

  8. Transvaginal mesh procedures for pelvic organ prolapse.

    Science.gov (United States)

    Walter, Jens-Erik

    2011-02-01

    comparing transvaginal mesh systems with traditional vaginal prolapse repairs or with traditional use of graft material in the form of augmented colporrhaphy and sacral colpopexy. (III-C) 5. Until appropriate supportive data are available, new trocarless kits should be considered investigative. (III-C).

  9. Vaginal bleeding between periods

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003156.htm Vaginal bleeding between periods To use the sharing features ... this page, please enable JavaScript. This article discusses vaginal bleeding that occurs between a woman's monthly menstrual ...

  10. Vaginal and Vulvar Cancer

    Science.gov (United States)

    VAGINAL & VULVAR CANCER Get the Facts About Gynecologic Cancer There are five main types of cancer that affect a woman’s reproductive organs: cervical, ovarian, uterine, vaginal, and vulvar. As a group, they are referred ...

  11. Management of aerobic vaginitis.

    Science.gov (United States)

    Tempera, Gianna; Furneri, Pio Maria

    2010-01-01

    Aerobic vaginitis is a new nonclassifiable pathology that is neither specific vaginitis nor bacterial vaginosis. The diversity of this microbiological peculiarity could also explain several therapeutic failures when patients were treated for infections identified as bacterial vaginosis. The diagnosis 'aerobic vaginitis' is essentially based on microscopic examinations using a phase-contrast microscope (at ×400 magnification). The therapeutic choice for 'aerobic vaginitis' should take into consideration an antibiotic characterized by an intrinsic activity against the majority of bacteria of fecal origin, bactericidal effect and poor/absent interference with the vaginal microbiota. Regarding the therapy for aerobic vaginitis when antimicrobial agents are prescribed, not only the antimicrobial spectrum but also the presumed ecological disturbance on the anaerobic and aerobic vaginal and rectal microbiota should be taken into a consideration. Because of their very low impact on the vaginal microbiota, kanamycin or quinolones are to be considered a good choice for therapy. Copyright © 2010 S. Karger AG, Basel.

  12. Surgical management of lower urinary mesh perforation after mid-urethral polypropylene mesh sling: mesh excision, urinary tract reconstruction and concomitant pubovaginal sling with autologous rectus fascia.

    Science.gov (United States)

    Shah, Ketul; Nikolavsky, Dmitriy; Gilsdorf, Daniel; Flynn, Brian J

    2013-12-01

    We present our management of lower urinary tract (LUT) mesh perforation after mid-urethral polypropylene mesh sling using a novel combination of surgical techniques including total or near total mesh excision, urinary tract reconstruction, and concomitant pubovaginal sling with autologous rectus fascia in a single operation. We retrospectively reviewed the medical records of 189 patients undergoing transvaginal removal of polypropylene mesh from the lower urinary tract or vagina. The focus of this study is 21 patients with LUT mesh perforation after mid-urethral polypropylene mesh sling. We excluded patients with LUT mesh perforation from prolapse kits (n = 4) or sutures (n = 11), or mesh that was removed because of isolated vaginal wall exposure without concomitant LUT perforation (n = 164). Twenty-one patients underwent surgical removal of mesh through a transvaginal approach or combined transvaginal/abdominal approaches. The location of the perforation was the urethra in 14 and the bladder in 7. The mean follow-up was 22 months. There were no major intraoperative complications. All patients had complete resolution of the mesh complication and the primary symptom. Of the patients with urethral perforation, continence was achieved in 10 out of 14 (71.5 %). Of the patients with bladder perforation, continence was achieved in all 7. Total or near total removal of lower urinary tract (LUT) mesh perforation after mid-urethral polypropylene mesh sling can completely resolve LUT mesh perforation in a single operation. A concomitant pubovaginal sling can be safely performed in efforts to treat existing SUI or avoid future surgery for SUI.

  13. Early experience with mesh excision for adverse outcomes after transvaginal mesh placement using prolapse kits.

    Science.gov (United States)

    Ridgeway, Beri; Walters, Mark D; Paraiso, Marie Fidela R; Barber, Matthew D; McAchran, Sarah E; Goldman, Howard B; Jelovsek, J Eric

    2008-12-01

    The purpose of this study was to determine the complications, treatments, and outcomes in patients choosing to undergo removal of mesh previously placed with a mesh procedural kit. This was a retrospective review of all patients who underwent surgical removal of transvaginal mesh for mesh-related complications during a 3-year period at Cleveland Clinic. At last follow-up, patients reported degree of pain, level of improvement, sexual activity, and continued symptoms. Nineteen patients underwent removal of mesh during the study period. Indications for removal included chronic pain (6/19), dyspareunia (6/19), recurrent pelvic organ prolapse (8/19), mesh erosion (12/19), and vesicovaginal fistula (3/19), with most patients (16/19) citing more than 1 reason. There were few complications related to the mesh removal. Most patients reported significant relief of symptoms. Mesh removal can be technically difficult but appears to be safe with few complications and high relief of symptoms, although some symptoms can persist.

  14. Gluteo-vaginal fistula after posterior intravaginal slingplasty: a case report.

    Science.gov (United States)

    Grynberg, Michael; Teyssedre, Jacques; Staerman, Frederic

    2009-07-01

    In patients with posthysterectomy prolapse of the vaginal vault, the posterior intravaginal slingplasty (posterior IVS, Tyco Healthcare, USA) has been suggested as an alternative to traditional vaginal vault suspensions. The goal of this technique is to recreate the uterosacral ligaments and to reinforce the rectovaginal fascia with the use of prosthetic material. We report the case of a 53-year-old woman with a history of 27 months of perineal suppurative discharge after she underwent a vaginal vault prolapse and rectocele repair using a posterior IVS (Tyco Healthcare, USA). The IVS tape was reinforced by interposing a rectovaginal monofilament polypropylene mesh (Parietex, Sofradim, France). Imaging studies and surgical exploration confirmed infection of the IVS mesh with the formation of a gluteo-vaginal fistula while the rectovaginal mesh was intact.

  15. Erosive gastritis

    International Nuclear Information System (INIS)

    Mohammed, S.H.; Conrad, C.; Kjoergaad, J.

    1982-01-01

    Erosive gastritis is a well-defined radiologic and endoscopic entity. It is one of the common causes of upper gastrointestinal bleeding, yet it is seldom diagnosed and often confused with a number of other diseases. This communication re-emphasizes the characteristic endoscopic and radiologic features of erosive gastritis and its differential diagnosis. Two representative cases are reported. (orig.)

  16. Erosive gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, S.H.; Conrad, C.; Kjoergaad, J.

    1982-08-01

    Erosive gastritis is a well-defined radiologic and endoscopic entity. It is one of the common causes of upper gastrointestinal bleeding, yet it is seldom diagnosed and often confused with a number of other diseases. This communication re-emphasizes the characteristic endoscopic and radiologic features of erosive gastritis and its differential diagnosis. Two representative cases are reported.

  17. Anterior colporrhaphy versus transvaginal mesh for pelvic-organ prolapse.

    Science.gov (United States)

    Altman, Daniel; Väyrynen, Tapio; Engh, Marie Ellström; Axelsen, Susanne; Falconer, Christian

    2011-05-12

    The use of standardized mesh kits for repair of pelvic-organ prolapse has spread rapidly in recent years, but it is unclear whether this approach results in better outcomes than traditional colporrhaphy. In this multicenter, parallel-group, randomized, controlled trial, we compared the use of a trocar-guided, transvaginal polypropylene-mesh repair kit with traditional colporrhaphy in women with prolapse of the anterior vaginal wall (cystocele). The primary outcome was a composite of the objective anatomical designation of stage 0 (no prolapse) or 1 (position of the anterior vaginal wall more than 1 cm above the hymen), according to the Pelvic Organ Prolapse Quantification system, and the subjective absence of symptoms of vaginal bulging 12 months after the surgery. Of 389 women who were randomly assigned to a study treatment, 200 underwent prolapse repair with the transvaginal mesh kit and 189 underwent traditional colporrhaphy. At 1 year, the primary outcome was significantly more common in the women treated with transvaginal mesh repair (60.8%) than in those who underwent colporrhaphy (34.5%) (absolute difference, 26.3 percentage points; 95% confidence interval, 15.6 to 37.0). The surgery lasted longer and the rates of intraoperative hemorrhage were higher in the mesh-repair group than in the colporrhaphy group (Pmesh-repair group and 0.5% in the colporrhaphy group (P=0.07), and the respective rates of new stress urinary incontinence after surgery were 12.3% and 6.3% (P=0.05). Surgical reintervention to correct mesh exposure during follow-up occurred in 3.2% of 186 patients in the mesh-repair group. As compared with anterior colporrhaphy, use of a standardized, trocar-guided mesh kit for cystocele repair resulted in higher short-term rates of successful treatment but also in higher rates of surgical complications and postoperative adverse events. (Funded by the Karolinska Institutet and Ethicon; ClinicalTrials.gov number, NCT00566917.).

  18. Outcome of transvaginal mesh and tape removed for pain only.

    Science.gov (United States)

    Hou, Jack C; Alhalabi, Feras; Lemack, Gary E; Zimmern, Philippe E

    2014-09-01

    Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. The mesh controversy [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Joshua A. Cohn

    2016-09-01

    Full Text Available Pelvic organ prolapse and stress urinary incontinence are common conditions for which approximately 11% of women will undergo surgical intervention in their lifetime. The use of vaginal mesh for pelvic organ prolapse and stress urinary incontinence rose rapidly in the early 2000s as over 100 mesh products were introduced into the clinical armamentarium with little regulatory oversight for their use. US Food and Drug Administration Public Health Notifications in 2008 and 2011, as well as reclassification of transvaginal mesh for prolapse to class III in early 2016, were a response to debilitating complications associated with transvaginal mesh placement in many women. The midurethral sling has not been subject to the same reclassification and continues to be endorsed as the “gold standard” for surgical management of stress urinary incontinence by subspecialty societies. However, litigators have not differentiated between mesh for prolapse and mesh for incontinence. As such, all mesh, including that placed for stress urinary incontinence, faces continued controversy amidst an uncertain future. In this article, we review the background of the mesh controversy, recent developments, and the anticipated role of mesh in surgery for prolapse and stress urinary incontinence going forward.

  20. 3-year results of transvaginal cystocele repair with transobturator four-arm mesh: A prospective study of 105 patients.

    Science.gov (United States)

    Kdous, Moez; Zhioua, Fethi

    2014-12-01

    To evaluate the long-term efficacy and safety of transobturator four-arm mesh for treating cystoceles. In this prospective study, 105 patients had a cystocele corrected between January 2004 and December 2008. All patients had a symptomatic cystocele of stage ⩾2 according to the Baden-Walker halfway stratification. We used only the transobturator four-arm mesh kit (Surgimesh®, Aspide Medical, France). All surgical procedures were carried out by the same experienced surgeon. The patients' characteristics and surgical variables were recorded prospectively. The anatomical outcome, as measured by a physical examination and postoperative stratification of prolapse, and functional outcome, as assessed by a questionnaire derived from the French equivalents of the Pelvic Floor Distress Inventory, Pelvic Floor Impact Questionnaire and the Pelvic Organ Prolapse-Urinary Incontinence-Sexual Questionnaire, were considered as the primary outcome measures. Peri- and postoperative complications constituted the secondary outcome measures. At 36 months after surgery the anatomical success rate (stage 0 or 1) was 93%. On a functional level, all the scores of quality of life and sexuality were improved. The overall satisfaction score (visual analogue scale) was 71.4%. There were no perioperative adverse events. Mesh erosion was reported in 7.6% and mesh retraction in 5.7% of the patients. If the guidelines and precautions are followed, vaginal prosthetic surgery for genitourinary prolapse has shown long-term benefits. It provides excellent results both anatomically and functionally. However, complications are not negligible and some are specific to prosthetic surgery.

  1. Vaginal microbiota in menopause

    OpenAIRE

    Martinus Tarina; Larisa Paramitha; Evita Halim Effendi; Shannaz Nadia Yusharyahya; Hanny Nilasari; Wresti Indriatmi

    2016-01-01

    The human vagina together with its resident, microbiota, comprise a dynamic ecosystem. Normal microbiota is dominated by Lactobacillus species, and pathogen microbiota such as Gardnerella species and Bacteroides species can occur due to decrease in Lactobacillus domination. Lactobacillus plays an essential role in keeping normal vaginal microbiota in balance. Vaginal microbiota adapts to pH change and hormonal value. Changes in the vaginal microbiota over a woman’s lifespan will influence the...

  2. Clinical and ultrasonographic study of patients presenting with transvaginal mesh complications.

    Science.gov (United States)

    Manonai, Jittima; Rostaminia, Ghazaleh; Denson, Lindsay; Shobeiri, S Abbas

    2016-03-01

    The objective of this study was to investigate the clinical and ultrasonographic findings of women who had three-dimensional endovaginal ultrasound (EVUS) for the management of vaginal mesh complications. This was a retrospective study of patients that had EVUS due to mesh complications at a tertiary care center. The clinical charts were reviewed. The stored 3D volumes were reviewed regarding mesh information by two examiners independently. The predictive value of physical examination for detection of vaginal mesh was calculated. Patient outcomes were reviewed. Seventy-nine patients presented to our center because of their, or their physicians' concern regarding mesh complications. Forty-one (51.9%) had vaginal/pelvic pain, and 51/62 (82.2%) of sexually active women experienced dyspareunia. According to ultrasonographic findings, mesh or sling was not demonstrated in six patients who believed they have had mesh/sling implantation. The positive predictive value for vaginal examination was 94.5% (95% CI: 84.9%-98.8%), negative predictive value was 12.5% (95% CI: 2.8%-32.4%), sensitivity was 72.2% (95% CI: 59.4%-81.2%), and specificity was 50.0% (95% CI: 12.4%-87.6%). Fifty-four patients were indicated for surgical treatment. Median postoperative review was 12 (range, 3-18) months and 38/53 (71.7%) patients were satisfied. The most common complaints of vaginal mesh complications were pain and dyspareunia. EVUS appeared to be helpful for assessing mesh presence, location, and extent including planning for surgical intervention. © 2015 Wiley Periodicals, Inc.

  3. Vaginitis: diagnosis and management.

    Science.gov (United States)

    Faro, S

    1996-01-01

    The various conditions that give rise to vaginitis include specific and nonspecific entities, such as candidiasis, trichomoniasis, bacterial vaginosis, group B streptococcal vaginitis, purulent vaginitis, volvodynia, and vestibulitis. The patient with chronic vaginitis usually develops this condition because of a misdiagnosis. It is critical that patients who have chronic vaginitis be thoroughly evaluated to determine if there is a specific etiology and whether their condition is recurrent or persistent, or is a reinfection. This also must include obtaining a detailed history, beginning with the patient's best recollection of when she felt perfectly normal. The physician must have an understanding of a healthy vaginal ecosystem and what mechanisms are in place to maintain the equilibrium. The vaginal ecosystem is a complex system of micro-organisms interacting with host factors to maintain its equilibrium. The endogenous microflora consists of a variety of bacteria, which include aerobic, facultative and obligate anaerobic bacteria. These organisms exist in a commensal, synergistic or antagonistic relationship. Therefore, it is important to understand what factors control the delicate equilibrium of the vaginal ecosystem, and which factors, both endogenous and exogenous, can disrupt this system. It is also important for the physician to understand that when a patient has symptoms of vaginitis it is not always due to an infectious etiology. There are situations in which an inflammatory reaction occurs but the specific etiology may not be determined. Thus, it is important that the physician not rush through the history or the examination.

  4. To mesh or not to mesh: a review of pelvic organ reconstructive surgery

    Science.gov (United States)

    Dällenbach, Patrick

    2015-01-01

    Pelvic organ prolapse (POP) is a major health issue with a lifetime risk of undergoing at least one surgical intervention estimated at close to 10%. In the 1990s, the risk of reoperation after primary standard vaginal procedure was estimated to be as high as 30% to 50%. In order to reduce the risk of relapse, gynecological surgeons started to use mesh implants in pelvic organ reconstructive surgery with the emergence of new complications. Recent studies have nevertheless shown that the risk of POP recurrence requiring reoperation is lower than previously estimated, being closer to 10% rather than 30%. The development of mesh surgery – actively promoted by the marketing industry – was tremendous during the past decade, and preceded any studies supporting its benefit for our patients. Randomized trials comparing the use of mesh to native tissue repair in POP surgery have now shown better anatomical but similar functional outcomes, and meshes are associated with more complications, in particular for transvaginal mesh implants. POP is not a life-threatening condition, but a functional problem that impairs quality of life for women. The old adage “primum non nocere” is particularly appropriate when dealing with this condition which requires no treatment when asymptomatic. It is currently admitted that a certain degree of POP is physiological with aging when situated above the landmark of the hymen. Treatment should be individualized and the use of mesh needs to be selective and appropriate. Mesh implants are probably an important tool in pelvic reconstructive surgery, but the ideal implant has yet to be found. The indications for its use still require caution and discernment. This review explores the reasons behind the introduction of mesh augmentation in POP surgery, and aims to clarify the risks, benefits, and the recognized indications for its use. PMID:25848324

  5. Vaginal or uterine bleeding - overview

    Science.gov (United States)

    ... and other menstrual conditions; Abnormal menstrual periods; Abnormal vaginal bleeding ... There are many causes of abnormal vaginal bleeding. HORMONES ... Doctors call the problem abnormal uterine bleeding (AUB) . AUB ...

  6. Complications of transvaginal silicone-coated polyester synthetic mesh sling.

    Science.gov (United States)

    Govier, F E; Kobashi, K C; Kuznetsov, D D; Comiter, C; Jones, P; Dakil, S E; James, R

    2005-10-01

    To report a premarket multicenter trial to test the feasibility of a transvaginal silicone-coated polyester synthetic mesh sling in women with anatomic incontinence. Fifty-one patients in four centers underwent transvaginal placement of a silicone-coated polyester synthetic mesh sling (American Medical Systems) during an 8-month period. Of the 51 patients, 31 were part of a prospective institutional review board-approved feasibility trial in three centers funded by American Medical Systems (group 1) and 20 underwent implantation by a single surgeon and their data were retrospectively reviewed (group 2). The studies were done concomitantly, and all slings were fixed transvaginally with bone anchors. All patients in group 1 were followed up at 4 weeks, 6 months, and 1 year (as applicable) with repeat questionnaires, physical examinations, and pad tests. In group 1, 20 patients completed 6 months of follow-up. Ten patients (32%) required a second surgical procedure at an average of 183 days (range 68 to 343) postoperatively. Eight patients (26%) had vaginal extrusion of the mesh, one (3%) required sling lysis, and one (3%) required sling removal because of infection. In group 2, 8 patients (40%) underwent sling removal for vaginal extrusion at a mean of 160 days (range 83 to 214). Transvaginally placed silicone-coated mesh slings used for the treatment of urinary incontinence demonstrated an unacceptably high vaginal extrusion rate in this study. Once identified, this study was immediately terminated, and this product was not marketed for this application in the United States.

  7. In vitro extracellular matrix model to evaluate stroma cell response to transvaginal mesh.

    Science.gov (United States)

    Wu, Ming-Ping; Huang, Kuan-Hui; Long, Cheng-Yu; Yang, Chau-Chen; Tong, Yat-Ching

    2014-04-01

    The use of surgical mesh for female pelvic floor reconstruction has increased in recent years. However, there is paucity of information about the biological responses of host stroma cells to different meshes. This study was aimed to establish an in vitro experimental model to study the micro-environment of extracellular matrix (ECM) with embedded mesh and the stroma cell behaviors to different synthetic meshes. Matrigel multi-cellular co-culture system with embedded mesh was used to evaluate the interaction of stroma cells and synthetic mesh in a simulated ECM environment. Human umbilical vein endothelial cells (HUVEC) and NIH3T3 fibroblasts were inoculated in the system. The established multi-cellular Matrigel co-culture system was used to detect stroma cell recruitment and tube formation ability for different synthetic meshes. HUVEC and NIH3T3 cells were recruited into the mesh interstices and organized into tube-like structures in type I mesh material from Perigee, Marlex and Prolift 24 hr after cell inoculation. On the contrary, there was little recruitment of HUVEC and NIH3T3 cells into the type III mesh of intra-vaginal sling (IVS). The Matrigel multi-cellular co-culture system with embedded mesh offers a useful in vitro model to study the biological behaviors of stroma cells in response to different types of synthetic meshes. The system can help to select ideal mesh candidates before actual implantation into the human body. © 2013 Wiley Periodicals, Inc.

  8. Erosion of pelvicol used in sacrocolpopexy.

    Science.gov (United States)

    Mukati, Marium S; Shobeiri, S Abbas

    2013-01-01

    Biologic graft materials are used more frequently in pelvic reconstructive surgeries. We describe here the complete process of removal of such a biologic graft in the office. We report a case of a 69-year-old woman with pig dermal graft erosion 1 year after placement. The patient presented with complaints of vaginal discharge. Upon examination, the graft material was seen eroding through the vaginal apex. The pig tissue was removed whole and intact in the office without complications. Transvaginal removal of pig tissue in the office relieved the patient's symptoms.

  9. Vaginal toxic shock reaction triggering desquamative inflammatory vaginitis.

    Science.gov (United States)

    Pereira, Nigel; Edlind, Thomas D; Schlievert, Patrick M; Nyirjesy, Paul

    2013-01-01

    The study aimed to report 2 cases of desquamative inflammatory vaginitis associated with toxic shock syndrome toxin 1 (TSST-1)-producing Staphylococcus aureus strains. Case report of 2 patients, 1 with an acute and 1 with a chronic presentation, diagnosed with desquamative inflammatory vaginitis on the basis of clinical findings and wet mount microscopy. Pretreatment and posttreatment vaginal bacterial and yeast cultures were obtained. Pretreatment vaginal bacterial cultures from both patients grew TSST-1-producing S. aureus. Subsequent vaginal bacterial culture results after oral antibiotic therapy were negative. Desquamative inflammatory vaginitis may be triggered through TSST-1-mediated vaginal toxic shock reaction.

  10. Vaginal drug distribution modeling.

    Science.gov (United States)

    Katz, David F; Yuan, Andrew; Gao, Yajing

    2015-09-15

    This review presents and applies fundamental mass transport theory describing the diffusion and convection driven mass transport of drugs to the vaginal environment. It considers sources of variability in the predictions of the models. It illustrates use of model predictions of microbicide drug concentration distribution (pharmacokinetics) to gain insights about drug effectiveness in preventing HIV infection (pharmacodynamics). The modeling compares vaginal drug distributions after different gel dosage regimens, and it evaluates consequences of changes in gel viscosity due to aging. It compares vaginal mucosal concentration distributions of drugs delivered by gels vs. intravaginal rings. Finally, the modeling approach is used to compare vaginal drug distributions across species with differing vaginal dimensions. Deterministic models of drug mass transport into and throughout the vaginal environment can provide critical insights about the mechanisms and determinants of such transport. This knowledge, and the methodology that obtains it, can be applied and translated to multiple applications, involving the scientific underpinnings of vaginal drug distribution and the performance evaluation and design of products, and their dosage regimens, that achieve it. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Analysis of Vaginal Cell Populations during Experimental Vaginal Candidiasis

    OpenAIRE

    Fidel, Paul L.; Luo, Wei; Steele, Chad; Chabain, Joseph; Baker, Marc; Wormley, Floyd

    1999-01-01

    Studies with an estrogen-dependent murine model of vaginal candidiasis suggest that local cell-mediated immunity (CMI) is more important than systemic CMI for protection against vaginitis. The present study, however, showed that, compared to uninfected mice, little to no change in the percentage or types of vaginal T cells occurred during a primary vaginal infection or during a secondary vaginal infection where partial protection was observed. Furthermore, depletion of polymorphonuclear leuko...

  12. Vaginal Cancer—Patient Version

    Science.gov (United States)

    Two-thirds of vaginal cancer cases are caused by human papillomavirus (HPV). Vaccines that protect against infection with HPV may reduce the risk of vaginal cancer. When found early, vaginal cancer can often be cured. Start here to find information on vaginal cancer treatment and research.

  13. Anterior vaginal introitoplasty for an acquired sensation of wide vagina: a case report and new surgical intervention.

    Science.gov (United States)

    Ostrzenski, Adam

    2014-01-01

    A vaginal introital defect case and its symptomatology have never been published before. The objective of this presentation was to describe symptoms associated with an acquired sensation of wide vagina and to present a new surgical treatment for anterior vaginal introital defects. A 42-year-old, Caucasian woman, G4P4013, presented with a sensation of wide vagina at the vaginal opening and a history of colpoperineoplasty, without mesh, for the same condition 4 years prior. Clinical evaluation documented anterior vaginal introital defects and the absence of vaginal site-specific defects. Reconstruction of a vaginal introital defect was completed without complications. Surgical resolution of symptoms and signs of this condition were noted. Anterior vaginal introitoplasty can assist in the management of an acquired sensation of wide vagina.

  14. Hernia Surgical Mesh Implants

    Science.gov (United States)

    ... knitted mesh or non-knitted sheet forms. The synthetic materials used can be absorbable, non-absorbable or a combination of absorbable and non-absorbable materials. Animal-derived mesh are made of animal tissue, such as intestine or skin, that has been processed and disinfected to be ...

  15. Multiparous Ewe as a Model for Teaching Vaginal Hysterectomy Techniques.

    Science.gov (United States)

    Kerbage, Yohan; Cosson, Michel; Hubert, Thomas; Giraudet, Géraldine

    2017-12-01

    Despite being linked to improving patient outcomes and limiting costs, the use of vaginal hysterectomy is on the wane. Although a combination of reasons might explain this trend, one cause is a lack of practical training. An appropriate teaching model must therefore be devised. Currently, only low-fidelity simulators exist. Ewes provide an appropriate model for pelvic anatomy and are well-suited for testing vaginal mesh properties. This article sets out a vaginal hysterectomy procedure for use as an education and training model. A multiparous ewe was the model. Surgery was performed under general anesthesia. The ewe was in a lithotomy position resembling that assumed by women on the operating table. Two vaginal hysterectomies were performed on two ewes, following every step precisely as if the model were human. Each surgical step of vaginal hysterectomy performed on the ewe and on a woman were compared side by side. We identified that all surgical steps were particularly similar. The main limitations of this model are costs ($500/procedure), logistic problems (housing large animals), and public opposition to animal training models. The ewe appears to be an appropriate model for teaching and training of vaginal hysterectomy.

  16. Vaginal delivery - discharge

    Science.gov (United States)

    Pregnancy - discharge after vaginal delivery ... You may have bleeding from your vagina for up to 6 weeks. Early on, you may pass some small clots when you first get up. Bleeding will slowly become ...

  17. Can Vaginitis Be Prevented?

    Science.gov (United States)

    ... examples of safe sex. 1 Centers for Disease Control and Prevention. (2010). Self-study STD module—vaginitis . ... Halvorson New Chief of Gynecologic Health and Disease Branch Division of Epidemiology, Statistics, ...

  18. Outcomes of Autologous Fascia Pubovaginal Sling for Patients with Transvaginal Mesh Related Complications Requiring Mesh Removal.

    Science.gov (United States)

    McCoy, Olugbemisola; Vaughan, Taylor; Nickles, S Walker; Ashley, Matt; MacLachlan, Lara S; Ginsberg, David; Rovner, Eric

    2016-08-01

    We reviewed the outcomes of the autologous fascial pubovaginal sling as a salvage procedure for recurrent stress incontinence after intervention for polypropylene mesh erosion/exposure and/or bladder outlet obstruction in patients treated with prior transvaginal synthetic mesh for stress urinary incontinence. In a review of surgical databases at 2 institutions between January 2007 and June 2013 we identified 46 patients who underwent autologous fascial pubovaginal sling following removal of transvaginal synthetic mesh in simultaneous or staged fashion. This cohort of patients was evaluated for outcomes, including subjective and objective success, change in quality of life and complications between those who underwent staged vs concomitant synthetic mesh removal with autologous fascial pubovaginal sling placement. All 46 patients had received at least 1 prior mesh sling for incontinence and 8 (17%) had received prior transvaginal polypropylene mesh for pelvic organ prolapse repair. A total of 30 patients underwent concomitant mesh incision with or without partial excision and autologous sling placement while 16 underwent staged autologous sling placement. Mean followup was 16 months. Of the patients 22% required a mean of 1.8 subsequent interventions an average of 6.5 months after autologous sling placement with no difference in median quality of life at final followup. At last followup 42 of 46 patients (91%) and 35 of 46 (76%) had achieved objective and subjective success, respectively. There was no difference in subjective success between patients treated with a staged vs a concomitant approach (69% vs 80%, p = 0.48). Autologous fascial pubovaginal sling placement after synthetic mesh removal can be performed successfully in patients with stress urinary incontinence as a single or staged procedure. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  19. To mesh or not to mesh: a review of pelvic organ reconstructive surgery

    Directory of Open Access Journals (Sweden)

    Dällenbach P

    2015-04-01

    Full Text Available Patrick Dällenbach Department of Gynecology and Obstetrics, Division of Gynecology, Urogynecology Unit, Geneva University Hospitals, Geneva, Switzerland Abstract: Pelvic organ prolapse (POP is a major health issue with a lifetime risk of undergoing at least one surgical intervention estimated at close to 10%. In the 1990s, the risk of reoperation after primary standard vaginal procedure was estimated to be as high as 30% to 50%. In order to reduce the risk of relapse, gynecological surgeons started to use mesh implants in pelvic organ reconstructive surgery with the emergence of new complications. Recent studies have nevertheless shown that the risk of POP recurrence requiring reoperation is lower than previously estimated, being closer to 10% rather than 30%. The development of mesh surgery – actively promoted by the marketing industry – was tremendous during the past decade, and preceded any studies supporting its benefit for our patients. Randomized trials comparing the use of mesh to native tissue repair in POP surgery have now shown better anatomical but similar functional outcomes, and meshes are associated with more complications, in particular for transvaginal mesh implants. POP is not a life-threatening condition, but a functional problem that impairs quality of life for women. The old adage “primum non nocere” is particularly appropriate when dealing with this condition which requires no treatment when asymptomatic. It is currently admitted that a certain degree of POP is physiological with aging when situated above the landmark of the hymen. Treatment should be individualized and the use of mesh needs to be selective and appropriate. Mesh implants are probably an important tool in pelvic reconstructive surgery, but the ideal implant has yet to be found. The indications for its use still require caution and discernment. This review explores the reasons behind the introduction of mesh augmentation in POP surgery, and aims to

  20. Erhversbetinget erosion?

    DEFF Research Database (Denmark)

    Dige, Irene; Gjørup, Hans; Nyvad, Bente

    2012-01-01

    Baggrund – I forbindelse med dental erosion er en grundig udredning af patienten vigtig, således at årsagen til erosionernes opståen findes, og der kan iværksættes adækvat forebyggende indsats. En sådan udredning er ikke mindst vigtig, når arbejdsmiljøet mistænkes. Patienttilfælde – En 30-årig...... arbejdsskade, men ikke anerkendt, da erosioner ikke er optaget på Arbejdsskadestyrelsens liste over erhvervssygdomme. En systematisk registrering af lignende tilfælde kunne imidlertid på sigt ændre retspraksis for fremtidige patienter med arbejdsbetinget erosion....... patient, der arbejder som pladesmed, blev henvist til Landsdels- og Videnscenter, Århus Sygehus, med henblik på udredning af patientens kraftige slid. Patienten udviste ikke-alderssvarende tandslid af emalje og dentin svarende til erosion forårsaget af syredampe i arbejdsmiljøet, muligvis forstærket af...

  1. Operation for recurrent cystocele with anterior colporrhaphy or non-absorbable mesh: patient reported outcomes

    DEFF Research Database (Denmark)

    Nüssler, Emil Karl; Greisen, Susanne; Kesmodel, Ulrik Schiøler

    2013-01-01

    Abstract INTRODUCTION AND HYPOTHESIS: The aim of this study was to compare patient reported outcomes and complications after repair of recurrent anterior vaginal wall prolapse in routine health care settings using standard anterior colporrhaphy or non-absorbable mesh. METHODS: The study is based...... on prospective data from the Swedish National Register for Gynaecological Surgery. 286 women were operated on for recurrent anterior vaginal wall prolapse in 2008-2010; 157 women had an anterior colporrhaphy and 129 were operated on with a non-absorbable mesh. Pre-, and perioperative data were collected from...... (0.6 %) in the anterior colporrhaphy group (p = 0.58). The infection rate was higher after mesh (8.5 %) than after anterior colporrhaphy (2.5 %; OR 3.19 ; 1.07-14.25). CONCLUSION: Implantation of synthetic mesh during operation for recurrent cystocele more than doubled the cure rate, whereas...

  2. Dynamic evaluation of pelvic floor reconstructive surgery using radiopaque meshes and three-dimensional helical CT

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2010-04-01

    Full Text Available PURPOSE: This prospective study was performed to achieve visualization of the reestablishment of anatomy after reconstructive surgery in the different pelvic compartments with non-absorbable radiopaque meshes, providing valuable anatomic information for surgeons implanting meshes. MATERIALS AND METHODS: A total of 30 female patients with stress urinary incontinence (SUI, anterior and posterior vaginal wall prolapse, or both underwent surgical repair using radiopaque meshes after written informed consent. Patients with SUI underwent five different surgeries. Patients with anterior vaginal prolapse underwent a procedure using a combined pre-pubic and transobturator mesh, and those with posterior vaginal prolapse underwent posterior slingplasty. Three-dimensional reconstruction using helical CT was performed four weeks postoperatively. RESULTS: In all cases, the mesh was clearly visualized. Transobturator slings were shown at the midurethra, and the anchoring tails perforated the obturator foramen at the safety region. Mini-slings were in the proper place, and computed angiography revealed that the anchoring system was away from the obturator vessels. In patients undergoing procedure for anterior vaginal prolapse, both pre-pubic armpit and obturator slings were clearly seen and the mesh was in the proper position, supporting the bladder base and occluding the distal part of the urogenital hiatus. Transcoccygeal sacropexy revealed indirectly a well-supported "neo rectovaginal fascia" and the anchoring tails at the level of ischial spines. CONCLUSION: Three-dimensional helical tomography images of the female pelvis using radiopaque meshes have a potential role in improving our understanding of pelvic floor reconstructive surgeries. These radiopaque meshes might be the basis of a new investigative methodology.

  3. [TVT (transvaginal mesh) surgical method for complex resolution of pelvic floor defects].

    Science.gov (United States)

    Adamík, Z

    2006-01-01

    Assessment of the effects of a new surgical method for complex resolution of pelvic floor defects. Case study. Department of Obstetrics and Gynaecology, Bata Hospital, Zlín. We evaluated the procedures and results of the new TVM (transvaginal mesh) surgical method which we used in a group of 12 patients. Ten patients had vaginal prolapse following vaginal hysterectomy and in two cases there was uterine prolapse and vaginal prolapse. Only in one case there was a small protrusion in the range of 0.5 cm which we resolved by removal of the penetrated section. The resulting anatomic effect was very good in all the cases.

  4. Short-term complications associated with the use of transvaginal mesh in pelvic floor reconstructive surgery: Results from a multi-institutional prospectively maintained dataset.

    Science.gov (United States)

    Caveney, Maxx; Haddad, Devin; Matthews, Catherine; Badlani, Gopal; Mirzazadeh, Majid

    2017-11-01

    Vaginal reconstructive surgery can be performed with or without mesh. We sought to determine comparative rates of perioperative complications of native tissue versus vaginal mesh repairs for pelvic organ prolapse. Using the National Surgical Quality Improvement Program (NSQIP) database, we concatenated surgical data from vaginal procedures for prolapse repair, including anterior and posterior colporrhaphy, paravaginal defect repair, enterocele repair, and vaginal colpopexy using Current Procedural Terminology (CPT) coding. We stratified this data by the modifier associated with mesh usage at the time of the procedure. We then compared 30-day perioperative outcomes, postoperative complications (bleeding, infection, etc), and readmission rates between women with and without mesh-based repairs. We identified 10 657 vaginal reconstructive procedures without mesh and 959 mesh-based repairs from 2009 through 2013. Patients undergoing mesh repair were more likely to experience at least one complication than native tissue repair (9.28% vs 6.15%, P mesh group (11.37% vs 9.39%, P = 0.03). Procedures with mesh had a higher rate of perioperative bleeding requiring transfusion than native tissue repair (2.3% vs 0.49%, P surgical site infection (SSI) (0.52% vs 0.17%, P = 0.02). There were no significant differences in rates of readmission, superficial, or deep SSIs, pneumonia, urinary tract infection, sepsis, or renal failure. The use of vaginal mesh for pelvic organ prolapse repair appears to result in a higher rate of perioperative complications than native tissue repair. Patients undergoing these procedures should be counselled preoperatively concerning these risks. © 2017 Wiley Periodicals, Inc.

  5. Surgeon Experience and Complications of Transvaginal Prolapse Mesh.

    Science.gov (United States)

    Kelly, Erin C; Winick-Ng, Jennifer; Welk, Blayne

    2016-07-01

    To measure the proportion of women with transvaginal prolapse mesh complications and their association with surgeon volume. We conducted a retrospective, population-based cohort study of all women who underwent a mesh-based prolapse procedure using administrative data (hospital procedure and physician billing records) between 2002 and 2013 in Ontario, Canada. The primary outcome was surgical revision of the mesh. Primary exposure was surgeon volume: high (greater than the 75th percentile, requiring a median of five [interquartile range 5-6] procedures per year) and very high (greater than the 90th percentile, requiring a median of 13 [interquartile range 11-14] procedures per year) volume mesh implanters were identified each year. Primary analysis was an adjusted Cox proportional hazards model. A total of 5,488 women underwent mesh implantation by 1 of 368 unique surgeons. Median follow-up time was 5.4 (interquartile range 3.0-8.0) years. We found that 218 women (4.0%) underwent mesh reoperation a median of 1.17 (interquartile range 0.58-2.90) years after implantation. The hazard of reoperation for complications was only lower for patients of very high-volume surgeons (3.0% [145/3,001] compared with 4.8% [73/2,447], adjusted hazards ratio 0.59, 95% confidence interval 0.40-0.86). In multivariable modeling, younger age, concomitant hysterectomy, blood transfusion, and increased medical comorbidity were all associated with vaginal mesh reoperation. Approximately 5% of women who underwent mesh-based prolapse surgery required reoperation for a mesh complication within 10 years. The risk of reoperation was lowest for surgeons performing 14 or more procedures per year.

  6. Vaginal microbiota in menopause

    Directory of Open Access Journals (Sweden)

    Martinus Tarina

    2016-12-01

    Full Text Available The human vagina together with its resident, microbiota, comprise a dynamic ecosystem. Normal microbiota is dominated by Lactobacillus species, and pathogen microbiota such as Gardnerella species and Bacteroides species can occur due to decrease in Lactobacillus domination. Lactobacillus plays an essential role in keeping normal vaginal microbiota in balance. Vaginal microbiota adapts to pH change and hormonal value. Changes in the vaginal microbiota over a woman’s lifespan will influence the colonization of pathogenic microbes. They include changes in child, puberty, reproductive state, menopause, and postmenopause. Estrogen levels change will affect the colonization of pathogenic microbium, leading to genitourinary syndrome of menopause. Vulvovaginal atrophy is often found in postmenopausal women, and dominated by L. iners, Anaerococcus sp, Peptoniphilus sp, Prevotella sp, and Streptococcus sp. The normal vaginal microbiota’s imbalance in menopause will cause diseases such as bacterial vaginosis, and recurrent vulvovaginal candidiasis due to hormonal therapies. Changes in the vaginal microbiota due to bacterial vaginosis are characterized by decrease in H2O2-producing Lactobacillus. They are also caused by the increase in numbers and concentration of Gardnerella vaginalis, Mycoplasma hominis, and other anaerob species such as Peptostreptococci, Prevotella spp, and Mobiluncus spp.

  7. After vaginal delivery - in the hospital

    Science.gov (United States)

    After vaginal birth; Pregnancy - after vaginal delivery; Postpartum care - after vaginal delivery ... blood pressure, heart rate, and the amount of vaginal bleeding Check to make sure your uterus is ...

  8. Vaginal Cancer—Health Professional Version

    Science.gov (United States)

    Vaginal cancer is often squamous cell carcinoma. Other types of vaginal cancer are adenocarcinoma, melanoma, and sarcoma. Infection with certain types of human papillomavirus (HPV) causes most vaginal cancer. Find evidence-based information on vaginal cancer treatment and research.

  9. Geometrically Consistent Mesh Modification

    KAUST Repository

    Bonito, A.

    2010-01-01

    A new paradigm of adaptivity is to execute refinement, coarsening, and smoothing of meshes on manifolds with incomplete information about their geometry and yet preserve position and curvature accuracy. We refer to this collectively as geometrically consistent (GC) mesh modification. We discuss the concept of discrete GC, show the failure of naive approaches, and propose and analyze a simple algorithm that is GC and accuracy preserving. © 2010 Society for Industrial and Applied Mathematics.

  10. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis

    OpenAIRE

    Evelyn Kaambo; Evelyn Kaambo; Evelyn Kaambo; Charlene Africa; Ramadhani Chambuso; Ramadhani Chambuso; Jo-Ann Shelley Passmore; Jo-Ann Shelley Passmore; Jo-Ann Shelley Passmore

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low...

  11. Short term post-operative morphing of sacrocolpopexy mesh measured by magnetic resonance imaging.

    Science.gov (United States)

    Sindhwani, Nikhil; Callewaert, Geertje; Deprest, Thomas; Housmans, Susanne; Van Beckevoort, Dirk; Deprest, Jan

    2018-04-01

    Sacrocolpopexy (SC) involves suspension of the vaginal vault or cervix to the sacrum using a mesh. Following insertion, the meshes have been observed to have undergone dimensional changes. To quantify dimensional changes of meshes following implantation and characterize their morphology in-vivo. 24 patients underwent SC using PolyVinyliDeneFluoride mesh loaded with Fe 3 O 4 particles. Tailored anterior and posterior mesh flaps were sutured to the respective vaginal walls, uniting at the apex. The posterior flap continued to the sacrum and was attached there. Meshes were visualized on magnetic resonance (MR) imaging at 12 [3-12] (median [range]) months postoperatively and 3D models of the mesh were generated. Dynamic MR sequences were acquired during valsalva to record mesh mobility. The area of the vagina effectively supported by the mesh (Effective Support Area (ESA)) was calculated. The 3D models' wall thickness map was analyzed to identify the locations of mesh folding. Intraclass correlation (ICC) was calculated to test the reliability of the methods. To measure the laxity and flatness of the mesh, the curvature and the ellipticity of the sacral flap were calculated. The ESA calculation methodology had ICC = 0.97. A reduction of 75.49 [61.55-78.67] % (median [IQR]) in area, 47.64 [38.07-59.81] % in anterior flap, and of 23.95 [10.96-27.21] % in the posterior flap was measured. The mesh appeared thicker near its attachment at the sacral promontory (n = 19) and near the vaginal apex (n = 22). The laxity of the mesh was 1.13 [1.10-1.16] and 60.55 [49.76-76.25] % of the sacral flap was flat. We could not reliably measure mesh mobility (ICC = 0.16). A methodology for complete 3D characterization of SC meshes using MR images was presented. After implantation, the supported area is much lower than what is prepared prior to implantation. We propose this happened during the surgery itself. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Aerobic vaginitis in pregnancy.

    Science.gov (United States)

    Donders, Ggg; Bellen, G; Rezeberga, D

    2011-09-01

    Aerobic vaginitis (AV) is an alteration in vaginal bacterial flora that differs from bacterial vaginosis (BV). AV is characterised by an abnormal vaginal microflora accompanied by an increased localised inflammatory reaction and immune response, as opposed to the suppressed immune response that is characteristic of BV. Given the increased local production of interleukin (IL)-1, IL-6 and IL-8 associated with AV during pregnancy, not surprisingly AV is associated with an increased risk of preterm delivery, chorioamnionitis and funisitis of the fetus. There is no consensus on the optimal treatment for AV in pregnant or non-pregnant women, but a broader spectrum drug such as clindamycin is preferred above metronidazole to prevent infection-related preterm birth. The exact role of AV in pregnancy, the potential benefit of screening, and the use of newer local antibiotics, disinfectants, probiotics and immune modulators need further study. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

  13. Vaginal itching and discharge - child

    Science.gov (United States)

    Pruritus vulvae; Itching - vaginal area; Vulvar itching; Yeast infection - child ... Common causes of vaginal itching and discharge in young girls include: Chemicals such as perfumes and dyes in detergents, fabric softeners, creams, ointments, ...

  14. Vaginal bleeding in late pregnancy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000627.htm Vaginal bleeding in late pregnancy To use the sharing ... JavaScript. One out of 10 women will have vaginal bleeding during their 3rd trimester. At times, it ...

  15. Towards rebuilding vaginal support utilizing an extracellular matrix bioscaffold.

    Science.gov (United States)

    Liang, Rui; Knight, Katrina; Easley, Deanna; Palcsey, Stacy; Abramowitch, Steven; Moalli, Pamela A

    2017-07-15

    As an alternative to polypropylene mesh, we explored an extracellular matrix (ECM) bioscaffold derived from urinary bladder matrix (MatriStem™) in the repair of vaginal prolapse. We aimed to restore disrupted vaginal support simulating application via transvaginal and transabdominal approaches in a macaque model focusing on the impact on vaginal structure, function, and the host immune response. In 16 macaques, after laparotomy, the uterosacral ligaments and paravaginal attachments to pelvic side wall were completely transected (IACUC# 13081928). 6-ply MatriStem was cut into posterior and anterior templates with a portion covering the vagina and arms simulating uterosacral ligaments and paravaginal attachments, respectively. After surgically exposing the correct anatomical sites, in 8 animals, a vaginal incision was made on the anterior and posterior vagina and the respective scaffolds were passed into the vagina via these incisions (transvaginal insertion) prior to placement. The remaining 8 animals underwent the same surgery without vaginal incisions (transabdominal insertion). Three months post implantation, firm tissue bands extending from vagina to pelvic side wall appeared in both MatriStem groups. Experimental endpoints examining impact of MatriStem on the vagina demonstrated that vaginal biochemical and biomechanical parameters, smooth muscle thickness and contractility, and immune responses were similar in the MatriStem no incision group and sham-operated controls. In the MatriStem incision group, a 41% decrease in vaginal stiffness (P=0.042), a 22% decrease in collagen content (P=0.008) and a 25% increase in collagen subtypes III/I was observed vs. Sham. Active MMP2 was increased in both Matristem groups vs. Sham (both P=0.002). This study presents a novel application of ECM bioscaffolds as a first step towards the rebuilding of vaginal support. Pelvic organ prolapse is a common condition related to failure of the supportive soft tissues of the vagina

  16. Coarse mesh code development

    Energy Technology Data Exchange (ETDEWEB)

    Lieberoth, J.

    1975-06-15

    The numerical solution of the neutron diffusion equation plays a very important role in the analysis of nuclear reactors. A wide variety of numerical procedures has been proposed, at which most of the frequently used numerical methods are fundamentally based on the finite- difference approximation where the partial derivatives are approximated by the finite difference. For complex geometries, typical of the practical reactor problems, the computational accuracy of the finite-difference method is seriously affected by the size of the mesh width relative to the neutron diffusion length and by the heterogeneity of the medium. Thus, a very large number of mesh points are generally required to obtain a reasonably accurate approximate solution of the multi-dimensional diffusion equation. Since the computation time is approximately proportional to the number of mesh points, a detailed multidimensional analysis, based on the conventional finite-difference method, is still expensive even with modern large-scale computers. Accordingly, there is a strong incentive to develop alternatives that can reduce the number of mesh-points and still retain accuracy. One of the promising alternatives is the finite element method, which consists of the expansion of the neutron flux by piecewise polynomials. One of the advantages of this procedure is its flexibility in selecting the locations of the mesh points and the degree of the expansion polynomial. The small number of mesh points of the coarse grid enables to store the results of several of the least outer iterations and to calculate well extrapolated values of them by comfortable formalisms. This holds especially if only one energy distribution of fission neutrons is assumed for all fission processes in the reactor, because the whole information of an outer iteration is contained in a field of fission rates which has the size of all mesh points of the coarse grid.

  17. Analysis of Vaginal Cell Populations during Experimental Vaginal Candidiasis

    Science.gov (United States)

    Fidel, Paul L.; Luo, Wei; Steele, Chad; Chabain, Joseph; Baker, Marc; Wormley, Floyd

    1999-01-01

    Studies with an estrogen-dependent murine model of vaginal candidiasis suggest that local cell-mediated immunity (CMI) is more important than systemic CMI for protection against vaginitis. The present study, however, showed that, compared to uninfected mice, little to no change in the percentage or types of vaginal T cells occurred during a primary vaginal infection or during a secondary vaginal infection where partial protection was observed. Furthermore, depletion of polymorphonuclear leukocytes (PMN) had no effect on infection in the presence or absence of pseudoestrus. These results indicate a lack of demonstrable effects by systemic CMI or PMN against vaginitis and suggest that if local T cells are important, they are functioning without showing significant increases in numbers within the vaginal mucosa during infection. PMID:10338532

  18. Is vaginal hyaluronic acid as effective as vaginal estriol for vaginal dryness relief?

    Science.gov (United States)

    Stute, Petra

    2013-12-01

    In a multicenter, randomized, controlled, open-label, parallel- group trial hyaluronic acid vaginal gel (Hyalofemme) was compared to estriol vaginal cream (Ovestin) in women with vaginal dryness due to various causes. A total of 144 supposedly postmenopausal women below age 70 years were randomized in a 1:1 ratio to either receive hyaluronic acid vaginal gel (5 g per application) or estriol vaginal cream (0.5 g cream per application = 0.5 mg estriol) every 3 days for a total of ten applications, respectively. Exclusion criteria included vaginal infections, conventional contraindications to estrogens, use of vaginal products other than the investigational compounds, being unmarried, pregnant, or breastfeeding. The aim of the study was to test for non-inferiority of hyaluronic acid vaginal gel compared to estriol vaginal cream. The primary efficacy end point was the percentage (%) improvement in vaginal dryness, with the secondary end points being the percentage (%) improvements in vaginal itching, burning, and dyspareunia. Efficacy was assessed by using a visual analog scale (VAS) (0-10; 0 = absent, 10 = intolerable) at baseline (V0), during telephone contact after the third administration (V1), and at the final visit after the tenth administration (V2). Safety parameters included vaginal pH, endometrial thickness, and a vaginal smear for vaginal microecosystem assessment. Adverse events were recorded according to international guidelines. 133 women completed the study. At baseline, participants' characteristics did not differ significantly. Mean age was 54 years, time since menopause was 5 years on average, and cause of menopause was mostly natural. However, mean menstrual cycle days were also reported, although according to inclusion criteria only postmenopausal women were eligible for the study. At V1, an improvement in vaginal dryness was reported by about 49 % of women using hyaluronic acid vaginal gel, and by 53 % of women using estriol vaginal cream (p = 0

  19. Long-term results of vaginal repairs with and without xenograft reinforcement

    DEFF Research Database (Denmark)

    Mouritsen, Lone; Kronschnabl, M.; Lose, G.

    2010-01-01

    The aim of this paper is to study if xenograft reinforcement of vaginal repair reduces recurrence of prolapse. Results 1-5 years after vaginal repair were studied in 41 cases with xenograft and in 82 matched controls without. Symptoms were evaluated by a validated questionnaire and anatomy...... in 3% of cases and 12% controls. None of the recurrence rates was significantly different for cases versus controls. No vaginal erosions were seen. Previous surgery was a significant risk factor with odds ratio 7.3 for another recurrence. Recurrence rates defined by POPQ plus symptoms were low compared...

  20. Long-term results of vaginal repairs with and without xenograft reinforcement

    DEFF Research Database (Denmark)

    Mouritsen, Lone; Kronschnabl, M.; Lose, G.

    2010-01-01

    INTRODUCTION AND HYPOTHESIS: The aim of this paper is to study if xenograft reinforcement of vaginal repair reduces recurrence of prolapse. METHODS: Results 1-5 years after vaginal repair were studied in 41 cases with xenograft and in 82 matched controls without. Symptoms were evaluated...... as POPQ > -1 plus symptoms revealed recurrence in 3% of cases and 12% controls. None of the recurrence rates was significantly different for cases versus controls. No vaginal erosions were seen. Previous surgery was a significant risk factor with odds ratio 7.3 for another recurrence. CONCLUSIONS...

  1. Documentation for MeshKit - Reactor Geometry (&mesh) Generator

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Rajeev [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-30

    This report gives documentation for using MeshKit’s Reactor Geometry (and mesh) Generator (RGG) GUI and also briefly documents other algorithms and tools available in MeshKit. RGG is a program designed to aid in modeling and meshing of complex/large hexagonal and rectilinear reactor cores. RGG uses Argonne’s SIGMA interfaces, Qt and VTK to produce an intuitive user interface. By integrating a 3D view of the reactor with the meshing tools and combining them into one user interface, RGG streamlines the task of preparing a simulation mesh and enables real-time feedback that reduces accidental scripting mistakes that could waste hours of meshing. RGG interfaces with MeshKit tools to consolidate the meshing process, meaning that going from model to mesh is as easy as a button click. This report is designed to explain RGG v 2.0 interface and provide users with the knowledge and skills to pilot RGG successfully. Brief documentation of MeshKit source code, tools and other algorithms available are also presented for developers to extend and add new algorithms to MeshKit. RGG tools work in serial and parallel and have been used to model complex reactor core models consisting of conical pins, load pads, several thousands of axially varying material properties of instrumentation pins and other interstices meshes.

  2. CFD study of fluid flow changes with erosion

    Science.gov (United States)

    López, Alejandro; Stickland, Matthew T.; Dempster, William M.

    2018-06-01

    For the first time, a three dimensional mesh deformation algorithm is used to assess fluid flow changes with erosion. The validation case chosen is the Jet Impingement Test, which was thoroughly analysed in previous works by Hattori et al. (Kenichi Sugiyama and Harada, 2008), Gnanavelu et al. in (Gnanavelu et al., 2009, 2011), Lopez et al. in (Lopez et al., 2015) and Mackenzie et al. in (Mackenzie et al., 2015). Nguyen et al. (2014) showed the formation of a new stagnation area when the wear scar is deep enough by performing a three-dimensional scan of the wear scar after 30 min of jet impingement test. However, in the work developed here, this stagnation area was obtained solely by computational means. The procedure consisted of applying an erosion model in order to obtain a deformed geometry, which, due to the changes in the flow pattern lead to the formation of a new stagnation area. The results as well as the wear scar were compared to the results by Nguyen et al. (2014) showing the same trend. OpenFOAM® was the software chosen for the implementation of the deforming mesh algorithm as well as remeshing of the computational domain after deformation. Different techniques for mesh deformation and approaches to erosion modelling are discussed and a new methodology for erosion calculation including mesh deformation is developed. This new approach is independent of the erosion modelling approach, being applicable to both Eulerian and Lagrangian based equations for erosion calculation. Its different applications such as performance decay in machinery subjected to erosion as well as modelling of natural erosion processes are discussed here.

  3. Menopause and the vaginal microbiome.

    Science.gov (United States)

    Muhleisen, Alicia L; Herbst-Kralovetz, Melissa M

    2016-09-01

    For over a century it has been well documented that bacteria in the vagina maintain vaginal homeostasis, and that an imbalance or dysbiosis may be associated with poor reproductive and gynecologic health outcomes. Vaginal microbiota are of particular significance to postmenopausal women and may have a profound effect on vulvovaginal atrophy, vaginal dryness, sexual health and overall quality of life. As molecular-based techniques have evolved, our understanding of the diversity and complexity of this bacterial community has expanded. The objective of this review is to compare the changes that have been identified in the vaginal microbiota of menopausal women, outline alterations in the microbiome associated with specific menopausal symptoms, and define how hormone replacement therapy impacts the vaginal microbiome and menopausal symptoms; it concludes by considering the potential of probiotics to reinstate vaginal homeostasis following menopause. This review details the studies that support the role of Lactobacillus species in maintaining vaginal homeostasis and how the vaginal microbiome structure in postmenopausal women changes with decreasing levels of circulating estrogen. In addition, the associated transformations in the microanatomical features of the vaginal epithelium that can lead to vaginal symptoms associated with menopause are described. Furthermore, hormone replacement therapy directly influences the dominance of Lactobacillus in the microbiota and can resolve vaginal symptoms. Oral and vaginal probiotics hold great promise and initial studies complement the findings of previous research efforts concerning menopause and the vaginal microbiome; however, additional trials are required to determine the efficacy of bacterial therapeutics to modulate or restore vaginal homeostasis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Vaginal health in contraceptive vaginal ring users - A review.

    Science.gov (United States)

    Lete, Iñaki; Cuesta, María C; Marín, Juan M; Guerra, Sandra

    2013-08-01

    To provide an overview of the available data from clinical studies of vaginal conditions in women who use a vaginal ring as a contraceptive. A systematic review of the literature. Millions of women have already used the ethylene vinyl acetate vaginal ring that releases ethinylestradiol and etonogestrel for contraception. Because of its small size, more than four out of five women using the ring report that they do not feel it, even during sexual intercourse. No colposcopic or cytological changes have been observed in users, although approximately 10% have increased vaginal discharge. While in vitro studies have shown adhesion of Candida yeasts to the vaginal ring surface, clinical studies have not demonstrated a greater incidence of Candida infections compared to users of equivalent oral contraceptives. Some clinical studies suggest a lower incidence of bacterial vaginosis. No interaction exists between concomitant use of the vaginal ring and other drugs or products for vaginal use. The use of a contraceptive vaginal ring does not alter the vaginal ecosystem and therefore does not substantially affect vaginal health.

  5. Advantages of implantation of acellular porcine-derived mesh in the treatment of human rectocele – Case report

    Directory of Open Access Journals (Sweden)

    Tomasz Kościński

    2016-09-01

    The clinical experience and review of the literature by the authors suggest that a porcine-derived acellular mesh is non-cytotoxic, pyrogenic or allergenic, and the application of a biomesh in the management of rectocele is effective and safe, and the risk of mesh erosion is very low.

  6. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis.

    Science.gov (United States)

    Kaambo, Evelyn; Africa, Charlene; Chambuso, Ramadhani; Passmore, Jo-Ann Shelley

    2018-01-01

    A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV) and bacterial vaginosis (BV). The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial "health" in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery.

  7. Vaginal Microbiomes Associated With Aerobic Vaginitis and Bacterial Vaginosis

    Directory of Open Access Journals (Sweden)

    Evelyn Kaambo

    2018-03-01

    Full Text Available A healthy vaginal microbiota is considered to be significant for maintaining vaginal health and preventing infections. However, certain vaginal bacterial commensal species serve an important first line of defense of the body. Any disruption of this microbial barrier might result in a number of urogenital conditions including aerobic vaginitis (AV and bacterial vaginosis (BV. The health of the vagina is closely associated with inhabitant microbiota. Furthermore, these microbes maintain a low vaginal pH, prevent the acquisition of pathogens, stimulate or moderate the local innate immune system, and further protect against complications during pregnancies. Therefore, this review will focus on vaginal microbial “health” in the lower reproductive tract of women and on the physiological characteristics that determine the well-being of reproductive health. In addition, we explore the distinct versus shared characteristics of BV and AV, which are commonly associated with increased risk for preterm delivery.

  8. Pyomyositis after vaginal delivery.

    LENUS (Irish Health Repository)

    Gaughan, Eve

    2011-01-01

    Pyomyositis is a purulent infection of skeletal muscle that arises from haematogenous spread, usually with abscess formation. It can develop after a transient bacteraemia of any cause. This type of infection has never been reported before in the literature after vaginal delivery. A 34-year-old woman had progressive severe pain in the left buttock and thigh and weakness in the left lower limb day 1 post spontaneous vaginal delivery. MRI showed severe oedema of the left gluteus, iliacus, piriformis and adductor muscles of the left thigh and a small fluid collection at the left hip joint. She was diagnosed with pyomyositis. She had fever of 37.9°C immediately postpartum and her risk factors for bacteraemia were a mild IV cannula-associated cellulitis and labour itself. She required prolonged treatment with antibiotics before significant clinical improvement was noted.

  9. Vaginal microbicides and teenagers.

    Science.gov (United States)

    Rupp, Richard E; Rosenthal, Susan L

    2003-10-01

    Sexually active teens are at significant risk from sexually transmitted infections and girls and women bear the greatest burden of these infections. New methods, such as vaginal microbicides, would provide female controlled options. Microbicides are currently in development and thus it is timely to discuss the progress made and factors that may influence acceptability for teens. Microbicide development presents many challenges, and several different potential mechanisms of action are being explored. There is interest in these products from women and men, and specific preferences are being investigated. Adolescents, due to reproductive system immaturity, developing cognitive abilities and the psychosocial context of their relationships, present a special set of challenges in efforts to foster microbicide use. Vaginal microbicides are on the horizon. Further study into teen issues is required to develop successful strategies for marketing and encouraging adolescent use of microbicides.

  10. Toward An Unstructured Mesh Database

    Science.gov (United States)

    Rezaei Mahdiraji, Alireza; Baumann, Peter Peter

    2014-05-01

    Unstructured meshes are used in several application domains such as earth sciences (e.g., seismology), medicine, oceanography, cli- mate modeling, GIS as approximate representations of physical objects. Meshes subdivide a domain into smaller geometric elements (called cells) which are glued together by incidence relationships. The subdivision of a domain allows computational manipulation of complicated physical structures. For instance, seismologists model earthquakes using elastic wave propagation solvers on hexahedral meshes. The hexahedral con- tains several hundred millions of grid points and millions of hexahedral cells. Each vertex node in the hexahedrals stores a multitude of data fields. To run simulation on such meshes, one needs to iterate over all the cells, iterate over incident cells to a given cell, retrieve coordinates of cells, assign data values to cells, etc. Although meshes are used in many application domains, to the best of our knowledge there is no database vendor that support unstructured mesh features. Currently, the main tool for querying and manipulating unstructured meshes are mesh libraries, e.g., CGAL and GRAL. Mesh li- braries are dedicated libraries which includes mesh algorithms and can be run on mesh representations. The libraries do not scale with dataset size, do not have declarative query language, and need deep C++ knowledge for query implementations. Furthermore, due to high coupling between the implementations and input file structure, the implementations are less reusable and costly to maintain. A dedicated mesh database offers the following advantages: 1) declarative querying, 2) ease of maintenance, 3) hiding mesh storage structure from applications, and 4) transparent query optimization. To design a mesh database, the first challenge is to define a suitable generic data model for unstructured meshes. We proposed ImG-Complexes data model as a generic topological mesh data model which extends incidence graph model to multi

  11. Efficacy of anchoring the four-arm transvaginal mesh to the mid-urethra vs original surgery as a surgical correction for stress urine incontinence in coexisting anterior vaginal prolapse grades II and III: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Fekete, Zoltán; Surányi, Andrea; Rénes, Lórand; Németh, Gábor; Kozinszky, Zoltan

    2017-12-28

    The prevalence of obesity with aging is escalating alarmingly; and pelvic organ prolapse (POP) and stress urinary incontinence (SUI) are now becoming a growing epidemic among the elderly. Synthetic transvaginal mesh has been employed with increasing popularity in the treatment of POP and is usually highly effective in controlling the principal symptoms of prolapse. However, studies have reported that mesh operations provide fairly unfavorable SUI cure rates. Therefore, additional anti-incontinence surgical strategies are increasingly being scrutinized to achieve better postoperative continence without any significant side-effects for patients with both POP and SUI. We hypothesize that the modification with the fixing of the mesh to the mid-urethra is superior to the original transvaginal mesh operation (TVM) with regard to anti-incontinence. One hundred and thirty patients diagnosed with POP-Q II-III and concomitant SUI requiring surgical treatment will be included in this prospective, randomized, double-blind, controlled clinical trial. Patients will be randomly allocated to receive either original TVM (TVM group, n = 65) or modified TVM surgery (mTVM group, n = 65). As the primary outcome parameter, we will evaluate the objective SUI and POP cure rates. Secondary endpoints include postoperative morbidity as assessed with the International Urogynaecological Association classification and subjective prolapse and incontinence cure rates reported by questionnaires. Recognizing the importance of an additional surgical procedure for anti-incontinence management, we aim to investigate whether a stabilizing suturing of the mesh to the mid-urethra delivers superior SUI correction compared to the original prosthesis surgery. ClinicalTrials.gov, NCT02935803. Registered on 20 May 2016.

  12. Effects of vaginal prolapse surgery and ageing on vaginal vascularization

    OpenAIRE

    Weber, M.A.

    2016-01-01

    Ageing affects pelvic floor anatomy and function, resulting in several disorders like pelvic organ prolapse (POP), lower urinary tract symptoms and vaginal atrophy (VA). In this thesis we searched for methods to link the function of pelvic organs to physiological changes. The effects of POP and vaginal prolapse surgery on vaginal vascularization and the influence of ageing and topical oestrogens on pelvic floor disorders were examined. The lack of knowledge regarding the effects of ageing on ...

  13. The Disability Impact and Associated Cost per Disability in Women Who Underwent Surgical Revision of Transvaginal Mesh Kits for Prolapse Repair.

    Science.gov (United States)

    Javadian, Pouya; Shobeiri, S Abbas

    2017-09-13

    The aim of this study was to investigate disability impact in patients and cost to the families of patients who have had complications of transvaginal prolapse mesh kits and underwent surgical revision. Patients who developed complications of transvaginal mesh kits for prolapse and who had undergone vaginal prolapse mesh surgical revision/removal in 2009 to 2014 at a single institution were identified by Current Procedural Terminology codes. The group was invited to complete a phone survey pertaining to the initial vaginal mesh used for prolapse surgery utilizing Sheehan Disability Scale (scale 0-10) and Years of life Lived with Disability (YLDs) questionnaires. The data collected were used to estimate the disability and cost analysis. We used our data to estimate the economic and quality-of-life impact of vaginal mesh complications on patients in the United States RESULTS: Sixty-two patients (62/198 [31.2%]) were consented to participate and completed the questionnaires by phone. Extremely disabled patients were 18 (29%) of 62 of whole cases, and 5 (8%) of 62 reported that they had no disability after vaginal mesh surgery. The median for overall disability score after vaginal mesh procedure was 8 (which reflects marked disability on a scale of 0-10). The majority of patients missed a median of 12 months of their school or work because of their mesh complications. Thirty-seven (59.6%) of 62 did not improve after mesh removal. Twenty-one (33.9%) of 62 stated that their family income dropped because of productivity loss related to mesh complications. The mean time between vaginal mesh surgery and mesh removal procedure was 4.7 years. Sheehan Disability Scale scores are significantly correlated with YLDs outcomes. Patients' overall disability score showed a significant correlation with YLDs scores (P mesh for prolapse reduction complications had a sustained disability impact that continued despite mesh removal. Likewise, the complications were associated with

  14. Evaluation of mechanical properties in metal wire mesh supported selective catalytic reduction (SCR) catalyst structures

    Science.gov (United States)

    Rajath, S.; Siddaraju, C.; Nandakishora, Y.; Roy, Sukumar

    2018-04-01

    The objective of this research is to evaluate certain specific mechanical properties of certain stainless steel wire mesh supported Selective catalytic reduction catalysts structures wherein the physical properties of the metal wire mesh and also its surface treatments played vital role thereby influencing the mechanical properties. As the adhesion between the stainless steel wire mesh and the catalyst material determines the bond strength and the erosion resistance of catalyst structures, surface modifications of the metal- wire mesh structure in order to facilitate the interface bonding is therefore very important to realize enhanced level of mechanical properties. One way to enhance such adhesion properties, the stainless steel wire mesh is treated with the various acids, i.e., chromic acid, phosphoric acid including certain mineral acids and combination of all those in various molar ratios that could generate surface active groups on metal surface that promotes good interface structure between the metal- wire mesh and metal oxide-based catalyst material and then the stainless steel wire mesh is dipped in the glass powder slurry containing some amount of organic binder. As a result of which the said catalyst material adheres to the metal-wire mesh surface more effectively that improves the erosion profile of supported catalysts structure including bond strength.

  15. SUPERIMPOSED MESH PLOTTING IN MCNP

    Energy Technology Data Exchange (ETDEWEB)

    J. HENDRICKS

    2001-02-01

    The capability to plot superimposed meshes has been added to MCNP{trademark}. MCNP4C featured a superimposed mesh weight window generator which enabled users to set up geometries without having to subdivide geometric cells for variance reduction. The variance reduction was performed with weight windows on a rectangular or cylindrical mesh superimposed over the physical geometry. Experience with the new capability was favorable but also indicated that a number of enhancements would be very beneficial, particularly a means of visualizing the mesh and its values. The mathematics for plotting the mesh and its values is described here along with a description of other upgrades.

  16. Wireless mesh networks.

    Science.gov (United States)

    Wang, Xinheng

    2008-01-01

    Wireless telemedicine using GSM and GPRS technologies can only provide low bandwidth connections, which makes it difficult to transmit images and video. Satellite or 3G wireless transmission provides greater bandwidth, but the running costs are high. Wireless networks (WLANs) appear promising, since they can supply high bandwidth at low cost. However, the WLAN technology has limitations, such as coverage. A new wireless networking technology named the wireless mesh network (WMN) overcomes some of the limitations of the WLAN. A WMN combines the characteristics of both a WLAN and ad hoc networks, thus forming an intelligent, large scale and broadband wireless network. These features are attractive for telemedicine and telecare because of the ability to provide data, voice and video communications over a large area. One successful wireless telemedicine project which uses wireless mesh technology is the Emergency Room Link (ER-LINK) in Tucson, Arizona, USA. There are three key characteristics of a WMN: self-organization, including self-management and self-healing; dynamic changes in network topology; and scalability. What we may now see is a shift from mobile communication and satellite systems for wireless telemedicine to the use of wireless networks based on mesh technology, since the latter are very attractive in terms of cost, reliability and speed.

  17. Vaginal Discharge: What's Normal, What's Not

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Vaginal Discharge: What's Normal, What's Not KidsHealth / For Teens / ... Discharge: What's Normal, What's Not Print What Is Vaginal Discharge? Vaginal discharge is fluid that comes from ...

  18. Vaginitis: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish Vulvovaginitis - overview (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Vaginitis updates by ... Vaginitis test - wet mount Vulvovaginitis - overview Related Health Topics Trichomoniasis Vaginal Diseases Yeast Infections Other Languages Find ...

  19. An Iterative Method for Estimating Airfoil Deformation due to Solid Particle Erosion

    Directory of Open Access Journals (Sweden)

    Valeriu DRAGAN

    2014-04-01

    Full Text Available Helicopter blades are currently constructed with composite materials enveloping honeycomb cores with only the leading and trailing edges made of metal alloys. In some cases, the erosive wear of the bound between the composite skin and metallic leading edge leads to full blade failure. It is therefore the goal of this paper to provide a method for simulating the way an airfoil is deformed through the erosion process. The method involves computational fluid dynamics simulations, scripts for automatic meshing and spreadsheet calculators for estimating the erosion and, ultimately, the airfoil deformation. Further work could include more complex meshing scripts allowing the use of similar methods for turbo-machineries.

  20. No. 351-Transvaginal Mesh Procedures for Pelvic Organ Prolapse.

    Science.gov (United States)

    Larouche, Maryse; Geoffrion, Roxana; Walter, Jens-Erik

    2017-11-01

    This guideline reviews the evidence related to the risks and benefits of using transvaginal mesh in pelvic organ prolapse repairs in order to update recommendations initially made in 2011. Gynaecologists, residents, urologists, urogynaecologists, and other health care providers who assess, counsel, and care for women with pelvic organ prolapse. Adult women with symptomatic pelvic organ prolapse considering surgery and those who have previously undergone transvaginal mesh procedures for the treatment of pelvic organ prolapse. The discussion relates to transvaginal mesh procedures compared with other surgical options for pelvic organ prolapse (mainly about vaginal native tissue repairs and minimally about other alternatives such as biological and absorbable vaginal mesh and abdominally placed surgical mesh). The outcomes of interest are objective and subjective success rates and intraoperative and postoperative complications, such as adjacent organ injury (urinary, gastrointestinal), infection, hematoma/bleeding, vaginal mesh exposure, persistent pain, dyspareunia, de novo stress urinary incontinence, and reoperation. PubMed, Medline, the Cochrane Database, and EMBASE were searched using the key words pelvic organ prolapse/surgery*, prolapse/surgery*, surgical mesh, surgical mesh*/adverse effects, transvaginal mesh, and pelvic organ prolapse. were restricted to English or French language and human research. Articles obtained through this search strategy were included until the end of June 2016. Pertinent new studies were added up to September 2016. Grey literature was not searched. Clinical practice guidelines and guidelines of specialty societies were reviewed. Systematic reviews were included when available. Randomized controlled trials and observational studies were included when evidence for the outcome of interest or in the target population was not available from systematic reviews. New studies not yet included in systematic reviews were also included. Only

  1. Vaginal pressure during daily activities before and after vaginal repair

    DEFF Research Database (Denmark)

    Mouritsen, L; Hulbaek, M; Brostrøm, S

    2007-01-01

    The objective of the study was to measure vaginal pressure during various daily activities in patients before and after vaginal surgery for pelvic organ prolapse, searching data for evidence-based activity guidelines. Vaginal pressure (VP) was studied in 23 patients during activities such as rest......, pelvic floor contraction (PFC), coughing, Valsalva, rising from sitting to standing and lifting 2 and 5 kg with four different lifting techniques. VP was measured before, 1-5 days and 4-6 weeks after vaginal repair. Mean VP was four to five times higher during coughing and Valsalva compared to PFC...... was not related to the type of vaginal repair. The results imply that post-operative counselling should concentrate more on treating chronic cough and constipation than restrictions of moderate physical activities....

  2. Red herring vaginal discharge.

    Science.gov (United States)

    Lee, Jun Hee; Pringle, Kirsty; Rajimwale, Ashok

    2013-09-18

    Labial hair tourniquet syndrome is a rare condition that can be easily misdiagnosed and ultimately lead to irreversible damage. An 11-year-old premenarche girl presented with a 5-day history of pain and swelling in the labia with associated vaginal discharge. The general practitioner treated her with clotrimazole without improvement. On examination, there was an oedematous swelling of the right labia with a proximal hair tourniquet. Local anaesthetic was applied and the hair removed with forceps. There was instant relief of pain and the discharge stopped within 24 h. The patient was sent home with a course of antibiotics.

  3. Rainfall Erosivity in Europe

    DEFF Research Database (Denmark)

    Panagos, Panos; Ballabio, Cristiano; Borrelli, Pasquale

    2015-01-01

    Rainfall is one the main drivers of soil erosion. The erosive force of rainfall is expressed as rainfall erosivity. Rainfall erosivity considers the rainfall amount and intensity, and is most commonly expressed as the Rfactor in the USLE model and its revised version, RUSLE. At national...... and continental levels, the scarce availability of data obliges soil erosion modellers to estimate this factor based on rainfall data with only low temporal resolution (daily, monthly, annual averages). The purpose of this study is to assess rainfall erosivity in Europe in the form of the RUSLE R-factor, based...

  4. The IUGA/ICS classification of synthetic mesh complications in female pelvic floor reconstructive surgery: a multicenter study.

    Science.gov (United States)

    Miklos, John R; Chinthakanan, Orawee; Moore, Robert D; Mitchell, Gretchen K; Favors, Sheena; Karp, Deborah R; Northington, Gina M; Nogueiras, Gladys M; Davila, G Willy

    2016-06-01

    The objective was to report patterns of sling and transvaginal mesh-related complications using the IUGA/ICS classification of prosthesis-related complications. This was a retrospective chart review of all patients who underwent surgical removal of sling, transvaginal mesh, and sacrocolpopexy for mesh-related complications from 2011 to 2013 at three tertiary referral centers. The International Urogynecological Association (IUGA)/International Continence Society (ICS) classification system was utilized. We identified 445 patients with mesh complications, 506 pieces of synthetic mesh were removed, and 587 prostheses-related complications were classified. 3.7 % of patients had viscus organ penetration or vaginal exposure as their presenting chief complaint and 59.7 % were classified as not having any vaginal epithelial separation or category 1. The most common category was spontaneous pain (1Be: 32.5 %) followed by dyspareunia (1Bc: 14.7 %). The sling group was 20 % more likely to have pain compared with the pelvic organ prolapse (POP) mesh group (OR 1.2, 95 % CI 0.8-1.6). The most commonly affected site (S2) was away from the suture line (49 %). Compared with the sling group, the POP group had a higher rate of mesh exposure, which mostly occurred at the suture line area. The majority of patients presented with mesh-related complications more than 1 year post-insertion (T4; average 3.68 ± 2.47 years). Surgeons should be aware that patients with vaginal mesh complications routinely exhibit complications more than 1 year after the implantation with pain as the most common presenting symptom.

  5. Notes on the Mesh Handler and Mesh Data Conversion

    International Nuclear Information System (INIS)

    Lee, Sang Yong; Park, Chan Eok

    2009-01-01

    At the outset of the development of the thermal-hydraulic code (THC), efforts have been made to utilize the recent technology of the computational fluid dynamics. Among many of them, the unstructured mesh approach was adopted to alleviate the restriction of the grid handling system. As a natural consequence, a mesh handler (MH) has been developed to manipulate the complex mesh data from the mesh generator. The mesh generator, Gambit, was chosen at the beginning of the development of the code. But a new mesh generator, Pointwise, was introduced to get more flexible mesh generation capability. An open source code, Paraview, was chosen as a post processor, which can handle unstructured as well as structured mesh data. Overall data processing system for THC is shown in Figure-1. There are various file formats to save the mesh data in the permanent storage media. A couple of dozen of file formats are found even in the above mentioned programs. A competent mesh handler should have the capability to import or export mesh data as many as possible formats. But, in reality, there are two aspects that make it difficult to achieve the competence. The first aspect to consider is the time and efforts to program the interface code. And the second aspect, which is even more difficult one, is the fact that many mesh data file formats are proprietary information. In this paper, some experience of the development of the format conversion programs will be presented. File formats involved are Gambit neutral format, Ansys-CFX grid file format, VTK legacy file format, Nastran format and CGNS

  6. Vaginal haemangioendothelioma: an unusual tumour.

    LENUS (Irish Health Repository)

    Mohan, H

    2012-02-01

    Vaginal tumours are uncommon and this is a particularly rare case of a vaginal haemangioendothelioma in a 38-year-old woman. Initial presentation consisted of symptoms similar to uterovaginal prolapse with "something coming down". Examination under anaesthesia demonstrated a necrotic anterior vaginal wall tumour. Histology of the lesion revealed a haemangioendothelioma which had some features of haemangiopericytoma. While the natural history of vaginal haemangioendothelioma is uncertain, as a group, they have a propensity for local recurrence. To our knowledge this is the third reported case of a vaginal haemangioendothelioma. Management of this tumour is challenging given the paucity of literature on this tumour. There is a need to add rare tumours to our "knowledge bank" to guide management of these unusual tumours.

  7. Concomitant surgical correction of severe stress urinary incontinence and anterior vaginal wall prolapse by anterior vaginal wall wrap: 18 months outcomes

    Science.gov (United States)

    Zargham, Mahtab; Alizadeh, Farshid; Tadayyon, Farhad; Khorrami, Mohammad-Hatef; Nouri-Mahdavi, Kia; Gharaati, Mohammad Reza; Izadpanahi, Mohammad Hossein; Yazdani, Mohammad; Mazdak, Hamid

    2013-01-01

    Background: The aim of this study is to evaluate the outcome of an innovative, minimally invasive sling technique with autologous tissue in women with concomitant incontinence and anterior vaginal wall prolapse (AVWP). Materials and Methods: Fifty-six women with stress urinary incontinence (SUI) or mixed urinary incontinence and AVWP were randomly assigned into two groups: In Group A (26 patients), anterior colporrhaphy (Kelly placation) and sling placement using a strip of anterior vaginal wall were performed, and in Group B (30 patients), transvaginal mesh correction of AVWP and tension-free vaginal tape (TVT) insertion (retropubic – craniocaudal route) using polypropylene mesh were carried out. The patients were followed-up for over 18 months and were assessed objectively using a 48 h frequency-volume chart, a 48 h pad test and a standardized stress test. Related surgical complications and outcomes were recorded and compared. Results: Surgical cure rates for Group A and Group B at the first (3 days) and last (18 months) post-operative visits were 62% and 84%; and 54%, and 72%, respectively (P = 0.09 and 0.31). Complications occurred in 9 patients (44%) of Group B, but only 3 patients (12%) in Group A. Conclusion: Vaginal sling surgery using an anterior vaginal wall strip can improve SUI and in comparison with propylene mesh is associated with lower complication rates. Although, the surgical success rate of this technique is lower than T-Sling, larger studies with selected patients will help assess the suitable patients for this pelvic reconstructive surgery. PMID:24516492

  8. Concomitant surgical correction of severe stress urinary incontinence and anterior vaginal wall prolapse by anterior vaginal wall wrap: 18 months outcomes

    Directory of Open Access Journals (Sweden)

    Mahtab Zargham

    2013-01-01

    Full Text Available Background: The aim of this study is to evaluate the outcome of an innovative, minimally invasive sling technique with autologous tissue in women with concomitant incontinence and anterior vaginal wall prolapse (AVWP. Materials and Methods : Fifty-six women with stress urinary incontinence (SUI or mixed urinary incontinence and AVWP were randomly assigned into two groups: In Group A (26 patients, anterior colporrhaphy (Kelly placation and sling placement using a strip of anterior vaginal wall were performed, and in Group B (30 patients, transvaginal mesh correction of AVWP and tension-free vaginal tape (TVT insertion (retropubic - craniocaudal route using polypropylene mesh were carried out. The patients were followed-up for over 18 months and were assessed objectively using a 48 h frequency-volume chart, a 48 h pad test and a standardized stress test. Related surgical complications and outcomes were recorded and compared. Results: Surgical cure rates for Group A and Group B at the first (3 days and last (18 months post-operative visits were 62% and 84%; and 54%, and 72%, respectively (P = 0.09 and 0.31. Complications occurred in 9 patients (44% of Group B, but only 3 patients (12% in Group A. Conclusion: Vaginal sling surgery using an anterior vaginal wall strip can improve SUI and in comparison with propylene mesh is associated with lower complication rates. Although, the surgical success rate of this technique is lower than T-Sling, larger studies with selected patients will help assess the suitable patients for this pelvic reconstructive surgery.

  9. Streaming simplification of tetrahedral meshes.

    Science.gov (United States)

    Vo, Huy T; Callahan, Steven P; Lindstrom, Peter; Pascucci, Valerio; Silva, Cláudio T

    2007-01-01

    Unstructured tetrahedral meshes are commonly used in scientific computing to represent scalar, vector, and tensor fields in three dimensions. Visualization of these meshes can be difficult to perform interactively due to their size and complexity. By reducing the size of the data, we can accomplish real-time visualization necessary for scientific analysis. We propose a two-step approach for streaming simplification of large tetrahedral meshes. Our algorithm arranges the data on disk in a streaming, I/O-efficient format that allows coherent access to the tetrahedral cells. A quadric-based simplification is sequentially performed on small portions of the mesh in-core. Our output is a coherent streaming mesh which facilitates future processing. Our technique is fast, produces high quality approximations, and operates out-of-core to process meshes too large for main memory.

  10. Mapping erosion from space

    NARCIS (Netherlands)

    Vrieling, A.

    2007-01-01

    Soil erosion by water is the most important land degradation problem worldwide. Spatial information on erosion is required for defining effective soil and water conservation strategies. Satellite remote sensing can provide relevant input to regional erosion assessment. This thesis comprises a review

  11. Erosion-corrosion

    International Nuclear Information System (INIS)

    Aghili, B.

    1999-05-01

    A literature study on erosion-corrosion of pipings in the nuclear industry was performed. Occurred incidents are reviewed, and the mechanism driving the erosion-corrosion is described. Factors that influence the effect in negative or positive direction are treated, as well as programs for control and inspection. Finally, examples of failures from databases on erosion-corrosion are given in an attachment

  12. Assessing storm erosion hazards

    NARCIS (Netherlands)

    Ranasinghe, Ranasinghe W M R J B; Callaghan, D.; Ciavola, Paolo; Coco, Giovanni

    2017-01-01

    The storm erosion hazard on coasts is usually expressed as an erosion volume and/or associated episodic coastline retreat. The accurate assessment of present-day and future storm erosion volumes is a key task for coastal zone managers, planners and engineers. There are four main approaches that can

  13. Comparison of Midterm Efficiency and Complications of Tension-Free Vaginal Tape Alone and Tension-Free Vaginal Tape Performed with Vaginal Hysterectomy

    Directory of Open Access Journals (Sweden)

    Emre Sinan Güngör

    2017-09-01

    Full Text Available Aim: To evaluate and compare the results and complications of tension-free vaginal tape (TVT when performed alone or with vaginal hysterectomy (VH and to evaluate the mid-term success rates of TVT for both groups. Methods: A retrospective study was performed on 179 patients who had TVT alone for stress urinary incontinance (SUI or TVT with VH for SUI and vaginal prolapse. Demographic, outcome and complication data were obtained from medical records. The main outcome measures were postoperative SUI and voiding dysfunction. Results: The mean age of the patients who underwent TVT and TVT+VH were 50.2±6.8 and 52.2±8.1, respectively (p>0.05 and the mean parity was 4±2.07 and 4.15±2.02, respectively (p>0.05. The success rate was significantly higher in TVT alone group than in TVT+VH group (93.6% vs. 84.5%, p0.05. Overall complication rate was higher in TVT+VH group (4.2% vs. 9.5%, p<0.05. Postoperative residuel urine volumes were significantly higher than preoperative residuel urine volumes in both groups (p=0.001. Due to mesh rejection, second surgery was performed in one patient from both groups to reomove the mesh. Conclusion: Midterm success rates were significantly higher in TVT group than in TVT+VH group, but success rates in TVT+VH were acceptable. Overall complication rates were higher in TVT+VH group; requirement for a second surgery was similar for both groups.

  14. The effect of vaginal cream containing ginger in users of clotrimazole vaginal cream on vaginal candidiasis.

    Science.gov (United States)

    Shabanian, Sheida; Khalili, Sima; Lorigooini, Zahra; Malekpour, Afsaneh; Heidari-Soureshjani, Saeid

    2017-01-01

    Vulvovaginal candidiasis is one of the most common infections of the genital tract in women that causes many complications. Therefore, we examined the clinical effect of ginger cream along with clotrimazole compared to vaginal clotrimazole alone in this study. This double-blind clinical trial was conducted on 67 women admitted to the Gynecology Clinic of Hajar Hospital with vaginal candidiasis. The patients were divided randomly into two groups of 33 and 34 people. The diagnosis was made according to clinical symptoms, wet smear, and culture. Ginger-clotrimazole vaginal cream 1% and clotrimazole vaginal cream 1% were administered to groups 1 and 2, respectively, once a day for 7 days and therapeutic effects and symptoms were evaluated in readmission. Data analysis was performed using SPSS version 22, t -test and Chi-square. The mean value of variables itching ( P > 0.05), burning ( P > 0.05), and cheesy secretion ( P vaginal candidiasis.

  15. Episiotomy for vaginal birth

    Science.gov (United States)

    Carroli, Guillermo; Mignini, Luciano

    2014-01-01

    Background Episiotomy is done to prevent severe perineal tears, but its routine use has been questioned. The relative effects of midline compared with midlateral episiotomy are unclear. Objectives The objective of this review was to assess the effects of restrictive use of episiotomy compared with routine episiotomy during vaginal birth. Search methods We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register (March 2008). Selection criteria Randomized trials comparing restrictive use of episiotomy with routine use of episiotomy; restrictive use of mediolateral episiotomy versus routine mediolateral episiotomy; restrictive use of midline episiotomy versus routine midline episiotomy; and use of midline episiotomy versus mediolateral episiotomy. Data collection and analysis The two review authors independently assessed trial quality and extracted the data. Main results We included eight studies (5541 women). In the routine episiotomy group, 75.15% (2035/2708) of women had episiotomies, while the rate in the restrictive episiotomy group was 28.40% (776/2733). Compared with routine use, restrictive episiotomy resulted in less severe perineal trauma (relative risk (RR) 0.67, 95% confidence interval (CI) 0.49 to 0.91), less suturing (RR 0.71, 95% CI 0.61 to 0.81) and fewer healing complications (RR 0.69, 95% CI 0.56 to 0.85). Restrictive episiotomy was associated with more anterior perineal trauma (RR 1.84, 95% CI 1.61 to 2.10). There was no difference in severe vaginal/perineal trauma (RR 0.92, 95% CI 0.72 to 1.18); dyspareunia (RR 1.02, 95% CI 0.90 to 1.16); urinary incontinence (RR 0.98, 95% CI 0.79 to 1.20) or several pain measures. Results for restrictive versus routine mediolateral versus midline episiotomy were similar to the overall comparison. Authors’ conclusions Restrictive episiotomy policies appear to have a number of benefits compared to policies based on routine episiotomy. There is less posterior perineal trauma, less suturing and

  16. Pemphigus vulgaris localized to the vagina presenting as chronic vaginal discharge.

    Science.gov (United States)

    Batta, K; Munday, P E; Tatnall, F M

    1999-05-01

    Involvement in pemphigus vulgaris of the female genital tract including the vulva, vagina and cervix has previously been described. In all these cases other cutaneous and mucosal sites have also been affected at some time. We describe a case of pemphigus vulgaris which only involved the vaginal mucosa. The patient presented with a persistent vaginal discharge and examination showed extensive vaginal erosions. Histology of vaginal biopsies was non-diagnostic. The recognition that the vaginal changes may represent an immunobullous disease led to further vaginal biopsies on which direct immunofluorescence studies were performed. These biopsies showed IgG and C3 in the intercellular epidermis, suggesting a diagnosis of pemphigus vulgaris. During the 3-year period that the patient has been under review there have never been any other cutaneous or mucosal lesions. To our knowledge, this is the first case of pemphigus vulgaris localized exclusively to the vaginal mucosa. There was considerable delay in diagnosis and this case highlights how important it is to recognize that chronic mucosal lesions at genital sites may be caused by immunobullous diseases such as cicatricial pemphigoid and pemphigus, and to institute appropriate investigations.

  17. Surface meshing with curvature convergence

    KAUST Repository

    Li, Huibin; Zeng, Wei; Morvan, Jean-Marie; Chen, Liming; Gu, Xianfengdavid

    2014-01-01

    Surface meshing plays a fundamental role in graphics and visualization. Many geometric processing tasks involve solving geometric PDEs on meshes. The numerical stability, convergence rates and approximation errors are largely determined by the mesh qualities. In practice, Delaunay refinement algorithms offer satisfactory solutions to high quality mesh generations. The theoretical proofs for volume based and surface based Delaunay refinement algorithms have been established, but those for conformal parameterization based ones remain wide open. This work focuses on the curvature measure convergence for the conformal parameterization based Delaunay refinement algorithms. Given a metric surface, the proposed approach triangulates its conformal uniformization domain by the planar Delaunay refinement algorithms, and produces a high quality mesh. We give explicit estimates for the Hausdorff distance, the normal deviation, and the differences in curvature measures between the surface and the mesh. In contrast to the conventional results based on volumetric Delaunay refinement, our stronger estimates are independent of the mesh structure and directly guarantee the convergence of curvature measures. Meanwhile, our result on Gaussian curvature measure is intrinsic to the Riemannian metric and independent of the embedding. In practice, our meshing algorithm is much easier to implement and much more efficient. The experimental results verified our theoretical results and demonstrated the efficiency of the meshing algorithm. © 2014 IEEE.

  18. Surface meshing with curvature convergence

    KAUST Repository

    Li, Huibin

    2014-06-01

    Surface meshing plays a fundamental role in graphics and visualization. Many geometric processing tasks involve solving geometric PDEs on meshes. The numerical stability, convergence rates and approximation errors are largely determined by the mesh qualities. In practice, Delaunay refinement algorithms offer satisfactory solutions to high quality mesh generations. The theoretical proofs for volume based and surface based Delaunay refinement algorithms have been established, but those for conformal parameterization based ones remain wide open. This work focuses on the curvature measure convergence for the conformal parameterization based Delaunay refinement algorithms. Given a metric surface, the proposed approach triangulates its conformal uniformization domain by the planar Delaunay refinement algorithms, and produces a high quality mesh. We give explicit estimates for the Hausdorff distance, the normal deviation, and the differences in curvature measures between the surface and the mesh. In contrast to the conventional results based on volumetric Delaunay refinement, our stronger estimates are independent of the mesh structure and directly guarantee the convergence of curvature measures. Meanwhile, our result on Gaussian curvature measure is intrinsic to the Riemannian metric and independent of the embedding. In practice, our meshing algorithm is much easier to implement and much more efficient. The experimental results verified our theoretical results and demonstrated the efficiency of the meshing algorithm. © 2014 IEEE.

  19. Vaginal oxytetracycline concentrations.

    Science.gov (United States)

    Thin, R N; Al Rawi, Z H; Simmons, P D; Treharne, J; Tabaqchali, S

    1979-01-01

    Although tetracycline preparations are widely used in departments of genitourinary medicine, or sexually transmitted diseases clinics, little is known of the concentrations of these preparations in genital secretions. For this reason a microbiological method was used for estimating oxytetracycline concentrations in vaginal secretions. These concentrations varied from 0.6 to 6.5 microgram/ml in 19 women who had had sexual contact with a man with non-specific urethritis and who were taking oxytetracycline dihydrate 250 mg four times daily. They were well in excess of the minimum inhibitory concentration of oxytetracycline (0.2 microgram/ml) for the strains of Chlamydia trachomatis isolated from the patients with positive culture results. Thus, oxytetracycline 250 mg four times daily appears to be a satisfactory regimen for the treatment of chlamydial genital infection in women. PMID:509190

  20. Managing dental erosion.

    Science.gov (United States)

    Curtis, Donald A; Jayanetti, Jay; Chu, Raymond; Staninec, Michal

    2012-01-01

    The clinical signs of dental erosion are initially subtle, yet often progress because the patient remains asymptomatic, unaware and uninformed. Erosion typically works synergistically with abrasion and attrition to cause loss of tooth structure, making diagnosis and management complex. The purpose of this article is to outline clinical examples of patients with dental erosion that highlight the strategy of early identification, patient education and conservative restorative management. Dental erosion is defined as the pathologic chronic loss of dental hard tissues as a result of the chemical influence of exogenous or endogenous acids without bacterial involvement. Like caries or periodontal disease, erosion has a multifactorial etiology and requires a thorough history and examination for diagnosis. It also requires patient understanding and compliance for improved outcomes. Erosion can affect the loss of tooth structure in isolation of other cofactors, but most often works in synergy with abrasion and attrition in the loss of tooth structure (Table 1). Although erosion is thought to be an underlying etiology of dentin sensitivity, erosion and loss of tooth structure often occurs with few symptoms. The purpose of this article is threefold: first, to outline existing barriers that may limit early management of dental erosion. Second, to review the clinical assessment required to establish a diagnosis of erosion. And third, to outline clinical examples that review options to restore lost tooth structure. The authors have included illustrations they hope will be used to improve patient understanding and motivation in the early management of dental erosion.

  1. Fixation of Light Weight Polypropylene Mesh with n-Butyl-2-cyanocrylate in Pelvic Floor Surgery: Experimental Design Approach in Sheep for Effectiveness Evaluation

    Directory of Open Access Journals (Sweden)

    Sandra Barbosa

    2015-01-01

    Full Text Available Objective. The aim of this study was to find a proper experimental design and to evaluate n-butyl-2-cyanoacrylate (Histoacryl as a fixation method for a light-weight and large pore PP mesh (Synthetic PP Mesh-1 using the sheep as an animal model. Methods. Posterior vaginal implantation by means of episiotomy was used to implant 8 ewes which were evaluated macroscopically and histologically at 3 months (n=4 and 6 months (n=4 post-surgery. In previous pilot studies anterior vaginal implantation was evaluated, as well as different synthetic mesh materials, sizes and fixation methods (n=1 to 3 during three weeks. In all cases a clinical evaluation of the animal was performed. Results. A reduction in the mesh size (Synthetic PP Mesh-1 together with precise application of the surgical glue Histoacryl to fix the mesh yielded significantly better histocompatibility results (P<0.01 compared to larger size or other fixation methods. Conclusion. The combination of Synthetic PP Mesh-1 with Histoacryl offered a high degree of graft integration without vaginal ulceration and a minimal foreign body reaction, being the sheep a proper animal model to test these types of medical devices.

  2. Analysis of Surgical Outcomes and Determinants of Litigation Among Women With Transvaginal Mesh Complications.

    Science.gov (United States)

    Zoorob, Dani; Karram, Mickey; Stecher, Anna; Maxwell, Rose; Whiteside, James

    To identify litigation predictors among women with complications of transvaginal mesh. Chart review and patient survey were conducted among women who had undergone a complication-related explant of a transvaginal prolapse or incontinence sling mesh. Trained study personnel administered a 57-question survey addressing subjective complaints related to bowel, bladder, sexual dysfunction, and development of pain or recurrent prolapse. These data were analyzed with respect to the subject's reported pursuit of litigation related to the mesh complication. Categorical and continuous variables were analyzed using the χ test and the t test as indicated. Ninety-five (68%) of 139 women completed the surveys with 60% of the patients pursuing litigation at the time of the survey. Individual risk factors for pursuing litigation included development of vaginal pain after mesh placement (P = 0.01); dyspareunia after mesh placement (P = 0.01); persistence of dyspareunia, suprapubic pain, and groin pain after mesh excision (P = 0.04, P = 0.02, and P = 0.001, respectively); unsuccessful attempts at conservative management of pelvic pain using pelvic floor rehabilitation (P = 0.002). There is an association between a higher likelihood of pursuing litigation and new-onset or persistent pain symptoms attributable to transvaginal mesh.

  3. Drugs Approved for Vaginal Cancer

    Science.gov (United States)

    This page lists cancer drugs approved by the Food and Drug Administration (FDA) to prevent vaginal cancer. The list includes generic names and brand names. The drug names link to NCI’s Cancer Drug Information summaries.

  4. Urinary incontinence - vaginal sling procedures

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007376.htm Urinary incontinence - vaginal sling procedures To use the sharing features ... are types of surgeries that help control stress urinary incontinence . This is urine leakage that happens when you ...

  5. Leveraging the power of mesh

    Energy Technology Data Exchange (ETDEWEB)

    Glass, H. [Cellnet, Alpharetta, GA (United States)

    2006-07-01

    Mesh network applications are used by utilities for metering, demand response, and mobile workforce management. This presentation provided an overview of a multi-dimensional mesh application designed to offer improved scalability and higher throughput in advanced metering infrastructure (AMI) systems. Mesh applications can be used in AMI for load balancing and forecasting, as well as for distribution and transmission planning. New revenue opportunities can be realized through the application's ability to improve notification and monitoring services, and customer service communications. Mesh network security features include data encryption, data fragmentation and the automatic re-routing of data. In order to use mesh network applications, networks must have sufficient bandwidth and provide flexibility at the endpoint layer to support multiple devices from multiple vendors, as well as support multiple protocols. It was concluded that smart meters will not enable energy response solutions without an underlying AMI that is reliable, scalable and self-healing. .refs., tabs., figs.

  6. Vaginal rhinosporidiosis: a case report.

    Science.gov (United States)

    Jahan, S; Haque, M A; Nessa, F; Begum, A; Hasan, A H; Sen, S; Huq, M H

    2014-07-01

    The female genital tract is an extremely rare site for Rhinosporidiosis. Here we described a 13 year old girl who presented with a slow growing polypoid fleshy mass in the posterior vaginal wall near the orifice for 6 months with scanty bleeding from the mass. The girl was admitted to hospital with profuse watery vaginal discharge. Excision of the mass was followed by histopathological examination which confirmed the diagnosis Rhinosporidiosis.

  7. Laparoscopically assisted vaginal radical trachelectomy

    International Nuclear Information System (INIS)

    Bielik, T.; Karovic, M.; Trska, R.

    2013-01-01

    Purpose: Radical trachelectomy is a fertility-sparing procedure with the aim to provide adequate oncological safety to patients with cervical cancer while preserving their fertility. The purpose of this study was to retrospectively evaluate, in a series of 3 patients, the feasibility, morbidity, and safety of laparoscopically assisted vaginal radical trachelectomy for early cervical cancer. Patients and Methods: Three non consecutive patients with FIGO stage IA1 and IB1 cervical cancer was evaluated in a period of years 2008 - 2011. The patients underwent a laparoscopic pelvic lymphadenectomy and radical parametrectomy class II procedure according to the Piver classification. The section of vaginal cuff, trachelectomy, permanent cerclage and isthmo-vaginal anastomosis ware realised by vaginal approach. Results: The median operative time, the median blood loss and the mean number of resected pelvic nodes was comparable with published data. Major intraoperative complications did not occur and no patient required a blood transfusion. The median follow-up time was 33 (38-59) months. One vaginal recurrence occurred in 7 months after primary surgery. The patient was underwent a radicalisation procedure and adjuvant oncologic therapy and now is free of disease. Conclusions: Laparoscopically assisted vaginal radical trachelectomy (LAVRT)may be an alternative in fertility-preserving surgery for early cervical cancer. The procedure offers patients potential benefits of minimally invasive surgery with adequate oncological safety, but it should be reserved for oncologic surgeons trained in advanced laparoscopic procedures. (author)

  8. Recurrent vaginal discharge in children.

    Science.gov (United States)

    McGreal, Sharon; Wood, Paul

    2013-08-01

    Childhood vaginal discharge remains a frequent reason for referral from primary to secondary care. The Pediatric and Adolescent Gynecology (PAG) service at Kettering General Hospital was established in 1993 and provides a specialized service that meets the needs of children with gynaecological conditions. To investigate recurrent vaginal discharge noting symptomatology, defining pathogens, common and rarer causes, exploring management regimes, and any changes in practice over time. Retrospective review spanning 15 years identifying prepubertal children attending the outpatient PAG clinic with recurrent vaginal discharge. We reviewed the medical notes individually. 110 patients were identified; 85% were referred from primary care. The age distribution was bimodal at four and eight years. Thirty-five percent of our patients were discharged after the initial consultation. The commonest cause of discharge was vulvovaginitis (82%). Other important causes included suspected sexual abuse (5%), foreign body (3%), labial adhesions (3%), vaginal agenesis (2%). 35% of patients were admitted for vaginoscopy. Vaginal discharge is the most common gynecological symptom in prepubertal girls and can cause repeated clinical episodes. Vulvovaginitis is the most common cause and often responds to simple hygiene measures. Awareness of the less common causes of vaginal discharge is essential. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  9. Two new mini-slings compared with transobturator tension-free vaginal tape for treatment of stress urinary incontinence: A 1-year follow-up randomized controlled trial.

    Science.gov (United States)

    Gaber, Mohamed E; Borg, Tamer; Samour, Hazem; Nawara, Mai; Reda, Ahmed

    2016-12-01

    The aim of this study was to compare the outcome of two single-incision mini-slings (the Contasure-Needleless [C-NDL] and the endopelvic free anchorage) with the standard midurethral transobturator tension-free vaginal tape (TVT-O) procedure. A double blind randomized controlled study was conducted at Ain Shams University Maternity Hospital from August 2014 until July 2015. A total of 209 patients were randomized into three groups. The first group underwent the TVT-O procedure, the second group underwent the endopelvic free anchorage procedure and the third group underwent the C-NDL procedure. Patients were followed up for 12 months in terms of subjective cure, objective cure, and complications rate. After 12 months of follow-up, there were no differences among the three groups in terms of objective cure rate, subjective cure rate, patient satisfaction, or incidence of complications (de novo urge, hemorrhage, infection, and mesh erosion). The C-NDL was associated with a shorter operative time (P < 0.001) and less blood loss (P = 0.021) than the standard TVT-O. The new single-incision mini-slings showed similar efficacy and patient acceptance to that of the standard TVT-O for up to 12 months postoperatively with no difference in the complications rate. The C-NDL is associated with shorter operative time and less blood loss. © 2016 Japan Society of Obstetrics and Gynecology.

  10. [Operative vaginal deliveries training].

    Science.gov (United States)

    Dupuis, O

    2008-12-01

    The appropriate use of forceps, vacuums or spatulas facilitates the rapid delivery of foetuses faced with life-threatening situations. It also makes possible the relief of certain cases of prolonged second-stage labor. In France, operative vaginal delivery (OVD) accounts for approximately 10% of all births. OVD training aims to optimize maternal, as well as neonatal safety. It should enable trainees to indicate or contraindicate an OVD safely, as well as to choose the appropriate instrument, use it correctly, and master quality control principles. Traditional OVD training is confronted with both spatial and time-related limitations. Spatial constraints involve both the teacher and trainee who only have limited visual access to the pelvic canal, and the head of the foetus; the time constraint occurs whenever the OVD occurs in an emergency setting. These limitations have been further aggravated by new constraints: decreasing time dedicated to training (European safety rules prohibit work the day after night duty), increasing litigation, and constraints imposed by society. Training by means of simulation removes such limitations making it possible to both avoid exposing pregnant women to the hazards of traditional training, and adapt the training to the skills of each trainee. OVD training should include forceps, vacuums and the use of spatulas. The OVD skills of obstetricians should be audited regularly on both a personal and a confidential level. Such audits could be based on a method using a simulator. Prospective studies comparing traditional and simulation-based training should be encouraged.

  11. Aerobic vaginitis: no longer a stranger.

    Science.gov (United States)

    Donders, Gilbert G G; Bellen, Gert; Grinceviciene, Svitrigaile; Ruban, Kateryna; Vieira-Baptista, Pedro

    Aerobic vaginitis (AV) is the name given in 2002 to a vaginal infectious entity which was not recognized as such before. It is characterized by abnormal (dysbiotic) vaginal microflora containing aerobic, enteric bacteria, variable levels of vaginal inflammation and deficient epithelial maturation. Although AV and bacterial vaginosis (BV) share some characteristics, such as a diminished number or absence of lactobacilli, increased discharge (fishy smelling in BV, while in severe forms of AV, a foul, rather rotten smell may be present) and increased pH (often more pronounced in AV), there are also striking differences between the two. There is no inflammation in women with BV, whereas the vagina of women with AV often appears red and edematous, and may even display small erosions or ulcerations. The color of the discharge in BV is usually whitish or gray and of a watery consistency, whereas in AV it is yellow to green and rather thick and mucoid. Women with BV do not have dyspareunia, while some women with severe AV do. Finally, the microscopic appearance differs in various aspects, such as the presence of leucocytes and parabasal or immature epithelial cells in AV and the absence of the granular aspect of the microflora, typical of BV. Despite all these differences, the distinction between AV and BV was not recognized in many former studies, leading to incomplete and imprecise diagnostic workouts and erroneous management of patients in both clinical and research settings. The prevalence of AV ranges between 7 and 12%, and is therefore less prevalent than BV. Although still largely undiagnosed, many researchers and clinicians increasingly take it into account as a cause of symptomatic vaginitis. AV can co-occur with other entities, such as BV and candidiasis. It can be associated with dyspareunia, sexually transmitted infections (such as human papilloma virus, human immunodeficiency virus, Trichomonas vaginalis and Chlamydia trachomatis), chorioamnionitis, fetal

  12. Definition of a type of abnormal vaginal flora that is distinct from bacterial vaginosis: aerobic vaginitis.

    Science.gov (United States)

    Donders, Gilbert G G; Vereecken, Annie; Bosmans, Eugene; Dekeersmaecker, Alfons; Salembier, Geert; Spitz, Bernard

    2002-01-01

    To define an entity of abnormal vaginal flora: aerobic vaginitis. Observational study. University Hospital Gasthuisberg, Leuven, Belgium. 631 women attending for routine prenatal care or attending vaginitis clinic. Samples were taken for fresh wet mount microscopy of vaginal fluid, vaginal cultures and measurement of lactate, succinate and cytokine levels in vaginal fluid. Smears deficient in lactobacilli and positive for clue cells were considered to indicate a diagnosis of bacterial vaginosis. Aerobic vaginitis was diagnosed if smears were deficient in lactobacilli, positive for cocci or coarse bacilli, positive for parabasal epithelial cells, and/or positive for vaginal leucocytes (plus their granular aspect). Genital complaints include red inflammation, yellow discharge, vaginal dyspareunia. Group B streptococci, escherichia coli, staphylococcus aureus and trichomonas vaginalis are frequently cultured. Vaginal lactate concentration is severely depressed in women with aerobic vaginitis, as in bacterial vaginosis, but vaginal succinate is not produced. Also in contrast to bacterial vaginosis, aerobic vaginitis produces a host immune response that leads to high production of interleukin-6, interleukin-1-beta and leukaemia inhibitory factor in the vaginal fluid. Aerobic vaginitis is associated with aerobic micro-organisms, mainly group B streptococci and E. coli. Its characteristics are different from those of bacterial vaginosis and elicit an important host response. The most severe form of aerobic vaginitis equals desquamative inflammatory vaginitis. In theory, aerobic vaginitis may be a better candidate than bacterial vaginosis as the cause of pregnancy complications, such as ascending chorioamnionitis, preterm rupture of the membranes and preterm delivery.

  13. Clinical Characteristics of Aerobic Vaginitis and Its Association to Vaginal Candidiasis, Trichomonas Vaginitis and Bacterial Vaginosis

    OpenAIRE

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-01-01

    ABSTRACT Aim of the work: Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Materials and methods: Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. Examinatio...

  14. The Manchester procedure versus vaginal hysterectomy in the treatment of uterine prolapse

    DEFF Research Database (Denmark)

    Tolstrup, Cæcilie Krogsgaard; Lose, Gunnar; Klarskov, Niels

    2017-01-01

    INTRODUCTION AND HYPOTHESIS: Uterine prolapse is a common health problem and the number of surgical procedures is increasing. No consensus regarding the surgical strategy for repair of uterine prolapse exists. Vaginal hysterectomy (VH) is the preferred surgical procedure worldwide, but uterus......-intervention rate, complications and operative outcomes. METHODS: We systematically searched Embase, PubMed, the Cochrane databases, Clinicaltrials and Clinical trials register using the MeSh terms "uterine prolapse", "uterus prolapse", "vaginal prolapse" "pelvic organ prolapse", "prolapsed uterus", "Manchester...... procedure" and "vaginal hysterectomy". No limitations regarding language, study design or methodology were applied. In total, nine studies published from 1966 to 2014 comparing the MP to VH were included. RESULTS: The anatomical recurrence rate for the middle compartment was 4-7 % after VH, whereas...

  15. Streaming Compression of Hexahedral Meshes

    Energy Technology Data Exchange (ETDEWEB)

    Isenburg, M; Courbet, C

    2010-02-03

    We describe a method for streaming compression of hexahedral meshes. Given an interleaved stream of vertices and hexahedral our coder incrementally compresses the mesh in the presented order. Our coder is extremely memory efficient when the input stream documents when vertices are referenced for the last time (i.e. when it contains topological finalization tags). Our coder then continuously releases and reuses data structures that no longer contribute to compressing the remainder of the stream. This means in practice that our coder has only a small fraction of the whole mesh in memory at any time. We can therefore compress very large meshes - even meshes that do not file in memory. Compared to traditional, non-streaming approaches that load the entire mesh and globally reorder it during compression, our algorithm trades a less compact compressed representation for significant gains in speed, memory, and I/O efficiency. For example, on the 456k hexahedra 'blade' mesh, our coder is twice as fast and uses 88 times less memory (only 3.1 MB) with the compressed file increasing about 3% in size. We also present the first scheme for predictive compression of properties associated with hexahedral cells.

  16. Mesh Adaptation and Shape Optimization on Unstructured Meshes, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR CRM proposes to implement the entropy adjoint method for solution adaptive mesh refinement into the Loci/CHEM unstructured flow solver. The scheme will...

  17. In vivo retention of poloxamer-based in situ hydrogels for vaginal application in mouse and rat models

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2017-07-01

    Full Text Available The purpose of this study is to evaluate the in vivo retention capabilities of poloxamer-based in situ hydrogels for vaginal application with nonoxinol-9 as the model drug. Two in situ hydrogel formulations, which contained 18% poloxamer 407 plus 1% poloxamer 188 (GEL1, relative hydrophobic or 6% poloxamer 188 (GEL2, relative hydrophilic, were compared with respect to the rheological properties, in vitro hydrogel erosion and drug release. The vaginal retention capabilities of these hydrogel formulations were further determined in two small animal models, including drug quantitation of vaginal rinsing fluid in mice and isotope tracing with 99mTc in rats. The two formulations exhibited similar phase transition temperatures ranging from 27 to 32 °C. Increasing the content of poloxamer 188 resulted in higher rheological moduli under body temperature, but slightly accelerated hydrogel erosion and drug release. When compared in vivo, GEL1 was eliminated significantly slower in rat vagina than GEL2, while the vaginal retention of these two hydrogel formulations behaved similarly in mice. In conclusion, increases in the hydrophilic content of formulations led to faster hydrogel erosion, drug release and intravaginal elimination. Rats appear to be a better animal model than mice to evaluate the in situ hydrogel for vaginal application.

  18. Protection from erosion following wildfire

    Science.gov (United States)

    Peter R. Robichaud; William J. Elliot

    2006-01-01

    Erosion in the first year after a wildfire can be up to three orders of magnitude greater than the erosion from undisturbed forests. To mitigate potential postfire erosion, various erosion control treatments are applied on highly erodible areas with downstream resources in need of protection. Because postfire erosion rates generally decline by an order of magnitude for...

  19. Clinical characteristics of aerobic vaginitis and its association to vaginal candidiasis, trichomonas vaginitis and bacterial vaginosis.

    Science.gov (United States)

    Jahic, Mahira; Mulavdic, Mirsada; Nurkic, Jasmina; Jahic, Elmir; Nurkic, Midhat

    2013-12-01

    Examine clinical characteristics of aerobic vaginitis and mixed infection for the purpose of better diagnostic accuracy and treatment efficiency. Prospective research has been conducted at Clinic for Gynecology and Obstetrics, Department for Microbiology and Pathology at Polyclinic for laboratory diagnostic and Gynecology and Obstetrics Department at Health Center Sapna. Examination included 100 examinees with the signs of vaginitis. anamnesis, clinical, gynecological and microbiological examination of vaginal smear. The average age of the examinees was 32,62±2,6. Examining vaginal smears of the examinees with signs of vaginitis in 96% (N-96) different microorganisms have been isolated, while in 4% (N-4) findings were normal. AV has been found in 51% (N-51) of the examinees, Candida albicans in 17% (N-17), BV in 15% (N-15), Trichomonas vaginalis in 13% (N-13). In 21% (N-21) AV was diagnosed alone while associated with other agents in 30% (N-30). Most common causes of AV are E. coli (N-55) and E. faecalis (N-52). AV and Candida albicanis have been found in (13/30, 43%), Trichomonas vaginalis in (9/30, 30%) and BV (8/30, 26%). Vaginal secretion is in 70,05% (N-36) yellow coloured, red vagina wall is recorded in 31,13% (N-16) and pruritus in 72,54% (N-37). Increased pH value of vagina found in 94,10% (N-48). The average pH value of vaginal environment was 5,15±0,54 and in associated presence of AV and VVC, TV and BV was 5,29±0,56 which is higher value considering presence of AV alone but that is not statistically significant difference (p>0,05). Amino-odor test was positive in 29,94% (N-15) of associated infections. Lactobacilli are absent, while leukocytes are increased in 100% (N-51) of the examinees with AV. AV is vaginal infection similar to other vaginal infections. It is important to be careful while diagnosing because the treatment of AV differentiates from treatment of other vaginitis.

  20. Streptococcus agalactiae: a vaginal pathogen?

    Science.gov (United States)

    Maniatis, A N; Palermos, J; Kantzanou, M; Maniatis, N A; Christodoulou, C; Legakis, N J

    1996-03-01

    The significance of Streptococcus agalactiae as an aetiological agent in vaginitis was evaluated. A total of 6226 samples from women who presented with vaginal symptoms was examined. The presence of >10 leucocytes/high-power field (h.p.f.) was taken to be the criterion of active infection. S. agalactiae was isolated from 10.1% of these samples. The isolation rates of other common pathogens such as Candida spp., Gardnerella vaginalis and Trichomonas spp. were 54.1%, 27.2% and 4.2%, respectively, in the same group of patients. In contrast, the isolation rates of these micro-organisms in the group of patients who had no infection (S. agalactiae was isolated, it was the sole pathogen isolated (83%) and its presence was associated with an inflammatory response in 80% of patients. Furthermore, the relative risk of vaginal infection with S. agalactiae (2.38) in patients with purulent vaginal discharge was greater than that of Candida spp. infection (1.41) and lower than that of Trichomonas spp. infection (8.32). These data suggest that S. agalactiae in symptomatic women with microscopic evidence of inflammation should be considered a causative agent of vaginitis.

  1. Mersiline mesh in premaxillary augmentation.

    Science.gov (United States)

    Foda, Hossam M T

    2005-01-01

    Premaxillary retrusion may distort the aesthetic appearance of the columella, lip, and nasal tip. This defect is characteristically seen in, but not limited to, patients with cleft lip nasal deformity. This study investigated 60 patients presenting with premaxillary deficiencies in which Mersiline mesh was used to augment the premaxilla. All the cases had surgery using the external rhinoplasty technique. Two methods of augmentation with Mersiline mesh were used: the Mersiline roll technique, for the cases with central symmetric deficiencies, and the Mersiline packing technique, for the cases with asymmetric deficiencies. Premaxillary augmentation with Mersiline mesh proved to be simple technically, easy to perform, and not associated with any complications. Periodic follow-up evaluation for a mean period of 32 months (range, 12-98 months) showed that an adequate degree of premaxillary augmentation was maintained with no clinically detectable resorption of the mesh implant.

  2. Erosions on a prolapsed uterine in an old woman: an unusual manifestation of pemphigus vulgaris.

    Science.gov (United States)

    Ramezani, Ali; Ghandi, Narges; Akhyani, Maryam; Daneshpazhooh, Maryam; Naraghi, Zahra S; Chams-Davatchi, Cheyda

    2009-09-15

    Vaginal involvement in pemphigus vulgaris has previously been described. In all those cases a pelvic examination was needed to explore the lesions. We describe a patient with pemphigus vulgaris who had pemphigus erosions on a prolapsed uterus (i.e., on the everted surface of vagina). The patient had widespread lesions of pemphigus in other mucosal and cutaneous sites. Biopsy, antibodies against desmoglein 1 and 3, and direct and indirect immunofluorescence were confirming. The erosions on the prolapsed uterus were resistant to treatment; other mucosal and cutaneous lesions responded rapidly to prednisolone and azathioprine. After lowering the dose of prednisolone the patient was referred to a gynecologist for a vaginal hysterectomy. This case was unique because her vaginal lesions could be easily examined and followed.

  3. Saliva and dental erosion

    Directory of Open Access Journals (Sweden)

    Marília Afonso Rabelo Buzalaf

    2012-10-01

    Full Text Available Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. Objective: This review discusses the role of salivary factors on the development of dental erosion. Material and Methods: A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Results: Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Conclusions: Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  4. Scales and erosion

    Science.gov (United States)

    There is a need to develop scale explicit understanding of erosion to overcome existing conceptual and methodological flaws in our modelling methods currently applied to understand the process of erosion, transport and deposition at the catchment scale. These models need to be based on a sound under...

  5. Saliva and dental erosion.

    Science.gov (United States)

    Buzalaf, Marília Afonso Rabelo; Hannas, Angélicas Reis; Kato, Melissa Thiemi

    2012-01-01

    Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. This review discusses the role of salivary factors on the development of dental erosion. A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  6. GENERATION OF IRREGULAR HEXAGONAL MESHES

    Directory of Open Access Journals (Sweden)

    Vlasov Aleksandr Nikolaevich

    2012-07-01

    Decomposition is performed in a constructive way and, as option, it involves meshless representation. Further, this mapping method is used to generate the calculation mesh. In this paper, the authors analyze different cases of mapping onto simply connected and bi-connected canonical domains. They represent forward and backward mapping techniques. Their potential application for generation of nonuniform meshes within the framework of the asymptotic homogenization theory is also performed to assess and project effective characteristics of heterogeneous materials (composites.

  7. Field-aligned mesh joinery

    OpenAIRE

    Cignoni, Paolo; Pietroni, Nico; Malomo, Luigi

    2014-01-01

    Mesh joinery is an innovative method to produce illustrative shape approximations suitable for fabrication. Mesh joinery is capable of producing complex fabricable structures in an efficient and visually pleasing manner. We represent an input geometry as a set of planar pieces arranged to compose a rigid structure, by exploiting an efficient slit mechanism. Since slices are planar, to fabricate them a standard 2D cutting system is enough. We automatically arrange slices according to a smooth ...

  8. Methods to quantify the impacts of water erosion on productivity of tropical soils

    International Nuclear Information System (INIS)

    Obando, Franco H

    2000-01-01

    A review on methods to quantify the impacts of water erosion on soil properties and crop yield is presented. On the basis of results of soil losses through plastic shading meshes on oxisols in the eastern plains of Colombia, the experimental design to quantify erosion induced losses in soil productivity suggested by Stocking (1985) for tropical soils is modified. With the purpose of producing contrasting levels of natural erosion, simple 33% and 45% shading rates meshes, and superposed 33% and 45% meshes were used. These were stretched out on stocking 5 m x 10 m run-off plots at 40 cm height from soil surface. Annual soil losses produced under the above mentioned shading meshes treatments did not present significant differences. It was demonstrated that 33%, 45% as well as superposed 33% and 45% produce an equivalent surface cover, CVE, greater than 90% comparable to that produced by zero grazing Brachiaria decumbens pasture. Such results allowed presenting modifications to the stocking design. It is recommended to use alternated stripes of bare soil and shading meshes of different width to produce contrasting levels of equivalent soil surface cover and consequently contrasting erosion rates. Design of the modified stocking run-off plots, including collecting channels, collecting tanks and a Geib multibox divisor are presented

  9. Method and system for mesh network embedded devices

    Science.gov (United States)

    Wang, Ray (Inventor)

    2009-01-01

    A method and system for managing mesh network devices. A mesh network device with integrated features creates an N-way mesh network with a full mesh network topology or a partial mesh network topology.

  10. Road to recovery after transvaginal surgery for urethral mesh perforation: evaluation of outcomes and subsequent procedures.

    Science.gov (United States)

    Kowalik, Casey G; Cohn, Joshua A; Kakos, Andrea; Lang, Patrick; Reynolds, W Stuart; Kaufman, Melissa R; Karram, Mickey M; Dmochowski, Roger R

    2018-01-29

    Urethral injury resulting from transvaginal mesh slings is a rare complication with an estimated incidence of surgical management and functional outcomes of women presenting with urethral mesh perforation following midurethral sling (MUS) placement. This was a retrospective multicenter review of women who from January 2011 to March 2016 at two institutions underwent mesh sling excision for urethral perforation with Female Pelvic Medicine and Reconstructive Surgery fellowship-trained surgeons. Data comprising preoperative symptoms, operative details, and postoperative outcomes were collected by telephone (n 13) or based on their last follow-up appointment. Nineteen women underwent transvaginal sling excision for urethral mesh perforation. Eight (42%) patients had undergone previous sling revision surgery. Sixty percent of women had resolution of their pelvic pain postoperatively. At follow-up, 92% reported urinary incontinence (UI), and three had undergone five additional procedures for vaginal prolapse mesh exposure (n 1), incontinence (onabotulinum toxin injection n 1, rectus fascia autologous sling n 1), prolapse (colpopexy n 1), and pain (trigger-point injection n 1). Patient global impression of improvement data was available for 13 patients, of whom seven (54%) rated their postoperative condition as Very much better or Much better. The management of urethral mesh perforation is complex. Most women reported resolution of their pelvic pain and a high rate of satisfaction with their postoperative condition despite high rates of incontinence.

  11. Mesh versus non-mesh repair of ventral abdominal hernias

    International Nuclear Information System (INIS)

    Jawaid, M.A.; Talpur, A.H.

    2008-01-01

    To investigate the relative effectiveness of mesh and suture repair of ventral abdominal hernias in terms of clinical outcome, quality of life and rate of recurrence in both the techniques. This is a retrospective descriptive analysis of 236 patients with mesh and non-mesh repair of primary ventral hernias performed between January 2000 to December 2004 at Surgery Department, Liaquat University of Medical and Health Sciences, Jamshoro. The record sheets of the patients were analyzed and data retrieved to compare the results of both techniques for short-term and long-term results. The data retrieved is statistically analyzed on SPSS version 11. There were 43 (18.22%) males and 193 (81.77%) females with a mean age of 51.79 years and a range of 59 (81-22). Para-umbilical hernia was the commonest of ventral hernia and accounted for 49.8% (n=118) of the total study population followed by incisional hernia comprising 24% (n=57) of the total number. There was a significant difference in the recurrent rate at 3 years interval with 23/101 (22.77%) recurrences in suture-repaired subjects compared to 10/135 (7.40%) in mesh repair group. Chronic pain lasting up to 1-2 years was noted in 14 patients with suture repair. Wound infection is comparatively more common (8.14%) in mesh group. The other variables such as operative and postoperative complications, total hospital stay and quality of life is also discussed. Mesh repair of ventral hernia is much superior to non-mesh suture repair in terms of recurrence and overall outcome. (author)

  12. Vaginal birth after C-section

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000589.htm Vaginal birth after C-section To use the sharing ... the same way again. Many women can have vaginal deliveries after having a C-section in the ...

  13. VBAC (Vaginal Birth After C-Section)

    Science.gov (United States)

    Vaginal birth after C-section (VBAC) Overview If you've delivered a baby by C-section and ... between scheduling a repeat C-section or attempting vaginal birth after C-section (VBAC). For many women, ...

  14. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  15. What is vaginal birth after cesarean (VBAC)?

    Science.gov (United States)

    ... Pinterest Email Print What is vaginal birth after cesarean (VBAC)? VBAC refers to vaginal delivery of a baby after a previous pregnancy was delivered by cesarean delivery. In the past, pregnant women who had ...

  16. User Manual for the PROTEUS Mesh Tools

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Micheal A. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, Emily R. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-06-01

    This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial or .merge) can be used as “mesh” input for any of the mesh tools discussed in this manual.

  17. User Manual for the PROTEUS Mesh Tools

    International Nuclear Information System (INIS)

    Smith, Micheal A.; Shemon, Emily R.

    2015-01-01

    This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT M eshToMesh.x and the MT R adialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial or .merge) can be used as ''mesh'' input for any of the mesh tools discussed in this manual.

  18. Spontaneous rupture of vaginal enterocele

    DEFF Research Database (Denmark)

    Svendsen, J H; Galatius, H; Hansen, P K

    1985-01-01

    Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission.......Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission....

  19. Premenarchal, recurrent vaginal discharge associated with an incomplete obstructing longitudinal vaginal septum.

    Science.gov (United States)

    Hansen, Keith A; DeWitt, Jason

    2005-12-01

    To describe an unusual, premenarchal presentation of an obstructive vaginal anomaly. Case Report. University Medical Center. Premenarchal subject Vaginogram, vaginal septum resection. Vaginal septum resection with resolution of vaginal discharge. This case demonstrates some of the typical features of uterus didelphys bicollis with incomplete obstructing hemivagina, but had a unique presentation with premenarchal, recurrent vaginal discharge. Typically, patients with an obstructing mullerian anomaly present after menarche with pelvic pain and a mass. The vaginogram assists in the preoperative definition of abnormal anatomy which allows the surgeon to develop the most appropriate surgical approach. Resection of this incompletely obstructing vaginal septum resulted in resolution of the recurrent vaginal discharge.

  20. Evaluation of vaginal flora and antibiogram analysis in reproductive-age women with or without vaginitis in primary care settings

    OpenAIRE

    Alim, Ahmet; Çetin, Ali; Yıldız, Çağlar

    2009-01-01

    Aims: The treatment modalities of patients with vaginal discharge are generally related to their symptoms. The aim of this study was to evaluate vaginal flora and antibiogram analysis in reproductive-age women with or without vaginitis in primary care settings. Methods: Vaginal swabs were taken from 311 women who have vaginitis, and tested for the causative agents of vaginal discharge. The control group was 89 healthy women without vaginal discharge. Vaginal swaps were used in a commercial te...

  1. Effects of vaginal prolapse surgery and ageing on vaginal vascularization

    NARCIS (Netherlands)

    Weber, M.A.

    2016-01-01

    Ageing affects pelvic floor anatomy and function, resulting in several disorders like pelvic organ prolapse (POP), lower urinary tract symptoms and vaginal atrophy (VA). In this thesis we searched for methods to link the function of pelvic organs to physiological changes. The effects of POP and

  2. A New Method to Measure Vaginal Sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Introduction: Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. Aims: To develop a new method to measure vaginal sensibility. Methods: We

  3. A new method to measure vaginal sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. To develop a new method to measure vaginal sensibility. We developed a technique to measure the

  4. The Vaginal Microbiota of Guinea Pigs

    OpenAIRE

    Hafner, L. M.; Rush, C. M.; Timms, P.

    2011-01-01

    The vaginae of four guinea pigs were swabbed and samples cultured aerobically on horse blood agar, in 5 per cent carbon dioxide on MRS agar or anaerobically on anaerobic horse blood agar. Vaginal microbiota consisted almost exclusively of gram-positive bacteria including Corynebacterium, Streptococcus, Enterococcus, Staphylococcus and Lactobacillus species.Keywords: guinea pigs, vaginal microbiota, vaginal vaccines.

  5. Characterisation of the vaginal microflora of human ...

    African Journals Online (AJOL)

    Lactobacilli predominate normal vaginal microflora and are important in maintenance of vaginal health. The current study set out to identify and compare culture isolates of vaginal microflora of human immunodeficiency virus (HIV) positive (HIV+) and HIV negative (HIV-) women at different phases during menstrual cycle ...

  6. Ethinyl Estradiol and Etonogestrel Vaginal Ring

    Science.gov (United States)

    ... or infection of the vagina white or yellow vaginal discharge vaginal bleeding or spotting when it is not time ... Follow your doctor's directions for examining your breasts; report any lumps ... and ethinyl estradiol vaginal ring.Do not let anyone else use your ...

  7. Characterisation of the vaginal microflora of human ...

    African Journals Online (AJOL)

    Teresa kiama

    2014-02-26

    Feb 26, 2014 ... Lactobacilli predominate normal vaginal microflora and are important in maintenance of vaginal health. The current study set out to identify and compare culture isolates of vaginal microflora of human immunodeficiency virus (HIV) positive (HIV+) and HIV negative (HIV-) women at different phases during.

  8. Cache-Oblivious Mesh Layouts

    International Nuclear Information System (INIS)

    Yoon, S; Lindstrom, P; Pascucci, V; Manocha, D

    2005-01-01

    We present a novel method for computing cache-oblivious layouts of large meshes that improve the performance of interactive visualization and geometric processing algorithms. Given that the mesh is accessed in a reasonably coherent manner, we assume no particular data access patterns or cache parameters of the memory hierarchy involved in the computation. Furthermore, our formulation extends directly to computing layouts of multi-resolution and bounding volume hierarchies of large meshes. We develop a simple and practical cache-oblivious metric for estimating cache misses. Computing a coherent mesh layout is reduced to a combinatorial optimization problem. We designed and implemented an out-of-core multilevel minimization algorithm and tested its performance on unstructured meshes composed of tens to hundreds of millions of triangles. Our layouts can significantly reduce the number of cache misses. We have observed 2-20 times speedups in view-dependent rendering, collision detection, and isocontour extraction without any modification of the algorithms or runtime applications

  9. Connectivity editing for quadrilateral meshes

    KAUST Repository

    Peng, Chihan; Zhang, Eugene; Kobayashi, Yoshihiro; Wonka, Peter

    2011-01-01

    We propose new connectivity editing operations for quadrilateral meshes with the unique ability to explicitly control the location, orientation, type, and number of the irregular vertices (valence not equal to four) in the mesh while preserving sharp edges. We provide theoretical analysis on what editing operations are possible and impossible and introduce three fundamental operations to move and re-orient a pair of irregular vertices. We argue that our editing operations are fundamental, because they only change the quad mesh in the smallest possible region and involve the fewest irregular vertices (i.e., two). The irregular vertex movement operations are supplemented by operations for the splitting, merging, canceling, and aligning of irregular vertices. We explain how the proposed highlevel operations are realized through graph-level editing operations such as quad collapses, edge flips, and edge splits. The utility of these mesh editing operations are demonstrated by improving the connectivity of quad meshes generated from state-of-art quadrangulation techniques. © 2011 ACM.

  10. Connectivity editing for quadrilateral meshes

    KAUST Repository

    Peng, Chihan

    2011-12-12

    We propose new connectivity editing operations for quadrilateral meshes with the unique ability to explicitly control the location, orientation, type, and number of the irregular vertices (valence not equal to four) in the mesh while preserving sharp edges. We provide theoretical analysis on what editing operations are possible and impossible and introduce three fundamental operations to move and re-orient a pair of irregular vertices. We argue that our editing operations are fundamental, because they only change the quad mesh in the smallest possible region and involve the fewest irregular vertices (i.e., two). The irregular vertex movement operations are supplemented by operations for the splitting, merging, canceling, and aligning of irregular vertices. We explain how the proposed highlevel operations are realized through graph-level editing operations such as quad collapses, edge flips, and edge splits. The utility of these mesh editing operations are demonstrated by improving the connectivity of quad meshes generated from state-of-art quadrangulation techniques. © 2011 ACM.

  11. Physiological measures of vaginal vasocongestion

    NARCIS (Netherlands)

    Laan, E.; Everaerd, W.

    1998-01-01

    This paper reviews reliability, specificity, and practical applicability of the two most promising and widely used methods for measuring blood flow within the vagina: the oxygenation-temperature method and vaginal photoplethysmography. It was concluded that the oxygenation-temperature method and

  12. MRI in distal vaginal atresia

    International Nuclear Information System (INIS)

    Hugosson, C.; Jorulf, H.; Bakri, Y.

    1991-01-01

    Magnetric resonance imaging in two young females with abdominal pain revealed vaginal atresia with massive hematocolpos but a normal cervix and uterine body. Information obtained with MRI was superior to ultrasound and CT and is suggested as the examination of choice prior to surgical correction. (orig.)

  13. Vaginal leiomyoma: MRI features with pathologic correlation

    Directory of Open Access Journals (Sweden)

    Avantika Gupta

    2015-06-01

    Full Text Available We present a rare case of vaginal leiomyoma presenting as prolapsed vaginal mass in a 45 years old woman. The leiomyoma was found to arise from the right lateral vaginal fornix with a vascular stalk. MRI showed homogenous hypointense signals on T1W1 and iso to hyperintense signals on T2W1 images with moderate heterogenous enhancement on post contrast images. It was enucleated via vaginal route and the histopathological examination confirmed the diagnosis of vaginal leiomyoma.

  14. [Aerobic vaginitis--diagnostic problems and treatment].

    Science.gov (United States)

    Romanik, Małgorzata; Wojciechowska-Wieja, Anna; Martirosian, Gayane

    2007-06-01

    The diagnostic criteria and treatment of aerobic vaginitis--AV--have been summarized in this review. An expansion of mixed aerobic microflora, especially Group B Streptococcus--GBS, Escherichia coli--E. coli, Enterococcus spp., and the development of inflammation of the vaginal mucous membrane due to a decreasing amount of Lactobacillus spp., have been observed in women with AV. Disruptions of the vaginal ecosystem during AV cause an increase in pH to >6, a decrease in lactates concentration and an increase in proinflammatory cytokines concentration in vaginal discharge. An optimal treatment scheme for AV, which includes antibacterial agents and simultaneously normalizes the vaginal ecosystem, has not been established until today.

  15. Measurement of erosion: Is it possible?

    NARCIS (Netherlands)

    Stroosnijder, L.

    2005-01-01

    Reasons for erosion measurements are: (1) to determine the environmental impact of erosion and conservation practices, (2) scientific erosion research; (3) development and evaluation of erosion control technology; (4) development of erosion prediction technology and (5) allocation of conservation

  16. Numerical modelling of concentrated leak erosion during Hole Erosion Tests

    OpenAIRE

    Mercier, F.; Bonelli, S.; Golay, F.; Anselmet, F.; Philippe, P.; Borghi, R.

    2015-01-01

    This study focuses on the numerical modelling of concentrated leak erosion of a cohesive soil by a turbulent flow in axisymmetrical geometry, with application to the Hole Erosion Test (HET). The numerical model is based on adaptive remeshing of the water/soil interface to ensure accurate description of the mechanical phenomena occurring near the soil/water interface. The erosion law governing the interface motion is based on two erosion parameters: the critical shear stress and the erosion co...

  17. True vaginal prolapse in a bitch.

    Science.gov (United States)

    Alan, M; Cetin, Y; Sendag, S; Eski, F

    2007-08-01

    Frequently, vaginal fold prolapse is the protrusion of edematous vaginal tissue into and through the opening of the vulva occurring during proestrus and estrus stages of the sexual cycle. True vaginal prolapse may occur near parturition, as the concentration of serum progesterone declines and the concentration of serum oestrogen increases. In the bitch, this type of true vaginal prolapse is a very rare condition. This short communication describes a 5-year-old female, cross-breed dog in moderate condition, weighing 33 kg, with distocia and true vaginal prolapse. Abdominal palpation and transabdominal ultrasonography revealed live and dead foetuses in the uterine horns. One dead and four live fetuses were removed from uterus by cesarean section. The ovariohysterectomy was performed after repositioning the vaginal wall with a combination of traction from within the abdomen and external manipulation through the vulva. Re-occurrence of a vaginal prolapse was not observed and the bitch recovered completely after the surgical therapy. Compared to other vaginal disorders, vaginal prolapse is an uncommon condition in the bitch. In the present case, extreme tenesmus arising from distocia may have predisposed to the vaginal prolapse. The cause of dystocia was probably the disposition of the first foetus. We concluded that the vaginal prolapse was the result of dystocia in the present case.

  18. Effects of erosive, cariogenic or combined erosive/cariogenic challenges on human enamel: an in situ/ex vivo study.

    Science.gov (United States)

    Honório, H M; Rios, D; Santos, C F; Magalhães, A C; Buzalaf, M A R; Machado, M A A M

    2008-01-01

    Individuals with cariogenic diet can also consume erosive beverages. Thus, it seems necessary to investigate a possible caries/erosion interaction. To test in situ/ex vivo a combination of these challenges, 11 subjects wore intraoral appliances containing four enamel blocks randomly assigned. In the first 2-week phase, the appliances were immersed in a cola drink 3 times/day. Two blocks were free of plaque (erosion only: EO) and two blocks were covered with plaque (erosion + plaque: EP). In the second 2-week phase, four new blocks were all covered with plaque and subjected to a sucrose solution 8 times/day. Among the four new blocks, two were also subjected to the cola drink 3 times/day (erosion + caries: EC) while the other two were not (caries only: CO). Thus, in EO, the specimens were fixed at the intraoral appliance level. In EP, EC and CO they were fixed 1.0 mm under the appliance level and covered with plastic meshes for dental plaque accumulation. Changes in wear and hardness were measured. Data were tested using ANOVA and Tukey's test (p cariogenic challenges showed less enamel alterations when compared to erosive or cariogenic challenges only. (c) 2008 S. Karger AG, Basel.

  19. A preclinical evaluation of polypropylene/polylacticacid hybrid meshes for fascial defect repair using a rat abdominal hernia model.

    Directory of Open Access Journals (Sweden)

    Daniela Ulrich

    Full Text Available Synthetic mesh surgery for both abdominal and urogenital hernia repair is often unsatisfactory in the long-term due to postoperative complications. We hypothesized that a semi-degradable mesh hybrid may provide more appropriate biocompatibility with comparable mechanical properties. The aim was to compare its in vivo biocompatibility with a commercial polypropylene (PP mesh.72 rats were randomly allocated to either our new composite mesh (monofilament PP mesh knitted with polylactic-acid-fibers (PLA or to a commercially available PP mesh that was used as a control. 15, 90, and 180 days after implantation into the rat abdomen mesh tissue complexes were analysed for erosion, contraction, foreign body reaction, tissue integration and biomechanical properties.No differences were seen in regard to clinical parameters including erosion, contraction or infection rates between the two groups. Biomechanical properties including breaking load, stiffness and deformation did not show any significant differences between the different materials at any timepoint. Macrophage staining did not reveal any significant differences between the two groups or between timepoints either. In regard to collagen I there was significantly less collagen I in the PP group compared to the PP/ PLA group at day 180. Collagen III did not show any significant differences at any timepoint between the two groups.A PP/PLA hybrid mesh, leaving a low amount of PP after PLA degradation seems to have comparable biomechanical properties like PP at 180 days due to enhanced collagen production without significant differences in erosion, contraction, herniation or infection rates.

  20. The effects of hyaluronic acid vaginal gel on the vaginal epithelium of ovariectomized rats.

    Science.gov (United States)

    Liu, Shuai-Bin; Liu, Shao-Li; Gan, Xiao-Ling; Zhou, Qin; Hu, Li-Na

    2015-03-01

    Hyaluronic acid is one of the best materials of water retention which can be used in vaginal atrophy. This study is to evaluate the role and mechanism of the hyaluronic acid vaginal gel (Hyalofemme) in the vaginal epithelium of ovariectomized rats. Sixty SD rats were randomly divided into control group (Sham ovariectomy, Sham-OVX), tendency group (ovariectomy, OVX), and experiment group (ovariectomy+Hyalofemme, OVX+Hyalofemme). The hyaluronic acid vaginal gel was administered local vaginal therapy to the experiment group with cytologicaly confirmed vaginal atrophy. The doses were adjusted by animal weight according to human dosage. After daily treatment for 14 days, VEGF and P-AKT activations were detected by Western blot in the experiment group. The hyaluronic acid vaginal gel proved to be very effective in the cytological reversal of vaginal atrophy but did not increase uterine weight. Vaginal microecosystem indicators were negative in the control group and the experiment group. By contrast, the indicators were positive in the tendency group. Hyaluronic acid vaginal gel is effective in the reversal of vaginal atrophy and is beneficial for improving vaginal microecosystem in the postmenopausal rat model. The hyaluronic acid vaginal gel can also improve the repair capacity of the vaginal epithelium.

  1. Rainfall erosivity in Europe.

    Science.gov (United States)

    Panagos, Panos; Ballabio, Cristiano; Borrelli, Pasquale; Meusburger, Katrin; Klik, Andreas; Rousseva, Svetla; Tadić, Melita Perčec; Michaelides, Silas; Hrabalíková, Michaela; Olsen, Preben; Aalto, Juha; Lakatos, Mónika; Rymszewicz, Anna; Dumitrescu, Alexandru; Beguería, Santiago; Alewell, Christine

    2015-04-01

    Rainfall is one the main drivers of soil erosion. The erosive force of rainfall is expressed as rainfall erosivity. Rainfall erosivity considers the rainfall amount and intensity, and is most commonly expressed as the R-factor in the USLE model and its revised version, RUSLE. At national and continental levels, the scarce availability of data obliges soil erosion modellers to estimate this factor based on rainfall data with only low temporal resolution (daily, monthly, annual averages). The purpose of this study is to assess rainfall erosivity in Europe in the form of the RUSLE R-factor, based on the best available datasets. Data have been collected from 1541 precipitation stations in all European Union (EU) Member States and Switzerland, with temporal resolutions of 5 to 60 min. The R-factor values calculated from precipitation data of different temporal resolutions were normalised to R-factor values with temporal resolutions of 30 min using linear regression functions. Precipitation time series ranged from a minimum of 5 years to a maximum of 40 years. The average time series per precipitation station is around 17.1 years, the most datasets including the first decade of the 21st century. Gaussian Process Regression (GPR) has been used to interpolate the R-factor station values to a European rainfall erosivity map at 1 km resolution. The covariates used for the R-factor interpolation were climatic data (total precipitation, seasonal precipitation, precipitation of driest/wettest months, average temperature), elevation and latitude/longitude. The mean R-factor for the EU plus Switzerland is 722 MJ mm ha(-1) h(-1) yr(-1), with the highest values (>1000 MJ mm ha(-1) h(-1) yr(-1)) in the Mediterranean and alpine regions and the lowest (<500 MJ mm ha(-1) h(-1) yr(-1)) in the Nordic countries. The erosivity density (erosivity normalised to annual precipitation amounts) was also the highest in Mediterranean regions which implies high risk for erosive events and floods

  2. Gluteo-vaginal sinus formation complicating posterior intravaginal slingplasty followed by successful IVS removal. A case report and review of the literature.

    Science.gov (United States)

    Mikos, Themistoklis; Tsalikis, Tryfon; Papanikolaou, Alexios; Pournaropoulos, Fotios; Bontis, John N

    2008-03-01

    Posterior intravaginal slingplasty (IVS) is a technique used for the treatment of apical prolapse. Type III meshes have been mostly used with this technique. In this article, a case of bilateral gluteo-vaginal sinus tract formation that complicated a posterior vaginal slingplasty with a type III mesh is presented. At 3 months follow-up, the patient complained for bulking through the vagina, continuous offensive vaginal discharge, and constant pain at the buttocks. She had prolapse recurrence, and there was defective healing at the gluteal entry points of the posterior IVS. Ten months after the initial surgery, she underwent a laparotomic subtotal hysterectomy and sacrocervicopexy with prolene type I mesh. At the same time, the posterior mesh was removed allowing the surgeon to discover communication of the canal of the mesh extending from gluteal incisions to the vagina epithelium. The sinus tract was managed surgically with excision of the surrounding tissues. There was no recurrence or other complications at 2 months follow-up.

  3. Using rare earth element tracers and neutron activation analysis to study rill erosion process

    International Nuclear Information System (INIS)

    Li Mian; Li Zhanbin; Ding Wengfeng; Liu Puling; Yao Wenyi

    2006-01-01

    Spatially averaged soil erosion data provide little information on the process of rill erosion. The dynamically varied data on the temporal and spatial distributions in the rill erosion process are needed to better understand the erosion process and reveal its innate characteristics. The objectives of this study were to examine the feasibility and effectiveness of rare earth element (REE) tracers and the neutron activation analysis (NAA) method on the study of the rill erosion process and to reveal quantitatively the relationships and characteristics of temporal and spatial distributions of sediment yield in rill erosion. Four REEs were used to study the changeable process of rill erosion at 4 slope positions. Four water inflow rates were applied to a 0.3x5 m soil bed at 3 slopes of 10.5%, 15.8% and 21.2% in scouring experiments. All of the runoff was collected in the experiment. Each sample was air-dried and well mixed. Then 20 g of each sample was sieved through 100-mesh and about a 50 mg sample was weighed for analysis of the four elemental compositions by NAA. Results indicate that the REE tracers and NAA method can be used to not only quantitatively determine soil erosion amounts on different slope segments, but also to reveal the changeable process of rill erosion amount. All of the relative errors of the experimental results were less than 25%, which is considered satisfactory on the study of rill erosion process

  4. Using rare earth element tracers and neutron activation analysis to study rill erosion process

    Energy Technology Data Exchange (ETDEWEB)

    Li Mian [Yellow River Institute of Hydraulic Research, Yellow River Conservancy Commission, Key Laboratory of Yellow River Sediment Research of Ministry of Water Resources, Shunhelu 45, Zhengzhou, Henan 450003 (China)]. E-mail: hnli-mian@163.com; Li Zhanbin [Xi' an University of Technology, Xi' an, Shaanxi 710048 (China); Institute of Soil and Water Conservation, Chinese Academy of Sciences and Ministry of Water Resources, Yangling, Shaanxi 712100 (China); Ding Wengfeng [Institute of Soil and Water Conservation, Yangtse River' s Scientific Research Institute, Wuhan, Hubei 430010 (China); Liu Puling [Institute of Soil and Water Conservation, Chinese Academy of Sciences and Ministry of Water Resources, Yangling, Shaanxi 712100 (China); Yao Wenyi [Yellow River Institute of Hydraulic Research, Yellow River Conservancy Commission, Key Laboratory of Yellow River Sediment Research of Ministry of Water Resources, Shunhelu 45, Zhengzhou, Henan 450003 (China)

    2006-03-15

    Spatially averaged soil erosion data provide little information on the process of rill erosion. The dynamically varied data on the temporal and spatial distributions in the rill erosion process are needed to better understand the erosion process and reveal its innate characteristics. The objectives of this study were to examine the feasibility and effectiveness of rare earth element (REE) tracers and the neutron activation analysis (NAA) method on the study of the rill erosion process and to reveal quantitatively the relationships and characteristics of temporal and spatial distributions of sediment yield in rill erosion. Four REEs were used to study the changeable process of rill erosion at 4 slope positions. Four water inflow rates were applied to a 0.3x5 m soil bed at 3 slopes of 10.5%, 15.8% and 21.2% in scouring experiments. All of the runoff was collected in the experiment. Each sample was air-dried and well mixed. Then 20 g of each sample was sieved through 100-mesh and about a 50 mg sample was weighed for analysis of the four elemental compositions by NAA. Results indicate that the REE tracers and NAA method can be used to not only quantitatively determine soil erosion amounts on different slope segments, but also to reveal the changeable process of rill erosion amount. All of the relative errors of the experimental results were less than 25%, which is considered satisfactory on the study of rill erosion process.

  5. Multigrid for refined triangle meshes

    Energy Technology Data Exchange (ETDEWEB)

    Shapira, Yair

    1997-02-01

    A two-level preconditioning method for the solution of (locally) refined finite element schemes using triangle meshes is introduced. In the isotropic SPD case, it is shown that the condition number of the preconditioned stiffness matrix is bounded uniformly for all sufficiently regular triangulations. This is also verified numerically for an isotropic diffusion problem with highly discontinuous coefficients.

  6. Coastal Erosion Control Methods

    Science.gov (United States)

    Greene, V.

    2016-12-01

    Coastal erosion is bad because the ecosystem there will be washed away and the animals could drown or be displaced and have to adapt to a new ecosystem that they are not prepared for. I'm interested in this problem because if there aren't beaches when I grow up I won't be able to do the things I would really like to do. I would like to be a marine biologist. Secondly, I don't want to see beach houses washed away. I would like to see people live in harmony with their environment. So, to study ways in which to preserve beaches I will make and use models that test different erosion controls. Two different ideas for erosion control I tested are using seaweed or a rock berm. I think the rock berm will work better than the model of seaweed because the seaweed is under water and the waves can carry the sand over the seaweed, and the rock berm will work better because the rocks will help break the waves up before they reach the shore and the waves can not carry the sand over the rocks that are above the water. To investigate this I got a container to use to model the Gulf of Mexico coastline. I performed several test runs using sand and water in the container to mimic the beach and waves from the Gulf of Mexico hitting the shoreline. I did three trials for the control (no erosion control), seaweed and a rock berm. Rock berms are a border of a raised area of rock. The model for seaweed that I used was plastic shopping bags cut into strips and glued to the bottom of my container to mimic seaweed. My results were that the control had the most erosion which ranged from 2.75 - 3 inches over 3 trials. The seaweed was a little better than the control but was very variable and ranged from 1.5 - 3 inches over 3 trials. The rock berm worked the best out of all at controlling erosion with erosion ranging from 1.5 - 2 inches. My hypothesis was correct because the rock berm did best to control erosion compared to the control which had no erosion control and the model with seaweed.

  7. Resterilized Polypropylene Mesh for Inguinal Hernia Repair

    African Journals Online (AJOL)

    2018-04-19

    Apr 19, 2018 ... Conclusion: The use of sterilized polypropylene mesh for the repair of inguinal ... and nonabsorbable materials to reduce the tissue–mesh. INTRODUCTION ... which we have been practicing in our center since we introduced ...

  8. 6th International Meshing Roundtable '97

    Energy Technology Data Exchange (ETDEWEB)

    White, D.

    1997-09-01

    The goal of the 6th International Meshing Roundtable is to bring together researchers and developers from industry, academia, and government labs in a stimulating, open environment for the exchange of technical information related to the meshing process. In the pas~ the Roundtable has enjoyed significant participation born each of these groups from a wide variety of countries. The Roundtable will consist of technical presentations from contributed papers and abstracts, two invited speakers, and two invited panels of experts discussing topics related to the development and use of automatic mesh generation tools. In addition, this year we will feature a "Bring Your Best Mesh" competition and poster session to encourage discussion and participation from a wide variety of mesh generation tool users. The schedule and evening social events are designed to provide numerous opportunities for informal dialog. A proceedings will be published by Sandia National Laboratories and distributed at the Roundtable. In addition, papers of exceptionally high quaIity will be submitted to a special issue of the International Journal of Computational Geometry and Applications. Papers and one page abstracts were sought that present original results on the meshing process. Potential topics include but are got limited to: Unstructured triangular and tetrahedral mesh generation Unstructured quadrilateral and hexahedral mesh generation Automated blocking and structured mesh generation Mixed element meshing Surface mesh generation Geometry decomposition and clean-up techniques Geometry modification techniques related to meshing Adaptive mesh refinement and mesh quality control Mesh visualization Special purpose meshing algorithms for particular applications Theoretical or novel ideas with practical potential Technical presentations from industrial researchers.

  9. Pelvic organ prolapse repair using the Uphold™ Vaginal Support System: a 1-year multicenter study.

    Science.gov (United States)

    Altman, Daniel; Mikkola, Tomi S; Bek, Karl Möller; Rahkola-Soisalo, Päivi; Gunnarsson, Jonas; Engh, Marie Ellström; Falconer, Christian

    2016-09-01

    The objective was to assess safety and clinical outcomes in women operated on using the Uphold™ Lite Vaginal Support System. We carried out a 1-year, multicenter, prospective, single cohort study of 207 women with symptomatic Pelvic Organ Prolapse Quantification (POP-Q) stage ≥2 apical pelvic organ prolapse, with or without concomitant anterior vaginal wall prolapse. Safety data were collected using a standardized questionnaire. Anatomical outcome was assessed by the POP-Q and subjective outcomes by the Pelvic Floor Distress Inventory after 2 months and 1 year using a one-way repeated measures analysis of variance. Pain was evaluated using a visual analog scale. The overall rate of serious complications was 4.3 % (9 out of 207 patients), including 3 patients with bladder perforations, 1 with bleeding >1,000 ml, 2 who had undergone re-operations with complete mesh removal because of pain, and 3 surgical interventions during follow-up because of mesh exposure. POP-Q stage ≤1 after 1 year was 94 % and subjective symptom relief was reported by 91 % of patients (p transvaginal mesh kits.

  10. Concurrent chemoradiation for vaginal cancer.

    Directory of Open Access Journals (Sweden)

    David T Miyamoto

    Full Text Available BACKGROUND: It is not known whether the addition of chemotherapy to radiation therapy improves outcomes in primary vaginal cancer. Here, we review clinical outcomes in patients with primary vaginal cancer treated with radiation therapy (RT or concurrent chemoradiation therapy (CRT. METHODS: Seventy-one patients with primary vaginal cancer treated with definitive RT with or without concurrent chemotherapy at a single institution were identified and their records reviewed. A total of 51 patients were treated with RT alone; 20 patients were treated with CRT. Recurrences were analyzed. Overall survival (OS and disease-free survival (DFS rates were estimated using the Kaplan-Meier method. Cox regression analysis was performed. RESULTS: The median age at diagnosis was 61 years (range, 18-92 years and the median follow-up time among survivors was 3.0 years. Kaplan-Meier estimates for OS and DFS differed significantly between the RT and CRT groups (3-yr OS = 56% vs. 79%, log-rank p = 0.037; 3-yr DFS = 43% vs. 73%, log-rank p = 0.011. Twenty-three patients (45% in the RT group had a relapse at any site compared to 3 (15% in the CRT group (p = 0.027. With regard to the sites of first relapse, 10 patients (14% had local only, 4 (6% had local and regional, 9 (13% had regional only, 1 (1% had regional and distant, and 2 (3% had distant only relapse. On univariate analysis, the use of concurrent chemotherapy, FIGO stage, tumor size, and date of diagnosis were significant predictors of DFS. On multivariate analysis, the use of concurrent chemotherapy remained a significant predictor of DFS (hazard ratio 0.31 (95% CI, 0.10-0.97; p = 0.04. CONCLUSIONS: Vaginal cancer results in poor outcomes. Adequate radiation dose is essential to ensure curative management. Concurrent chemotherapy should be considered for vaginal cancer patients.

  11. Lactobacillus for Vaginal Microflora Correction

    Directory of Open Access Journals (Sweden)

    Saule Saduakhasova

    2014-12-01

    Full Text Available Introduction. Despite the significant progress made in prevention, diagnosis, and treatment, there is still a high rate of vaginal dysbiosis in Kazakh women. The use of antibiotics in the treatment of vaginal dysbiosis contributes to the elimination of pathogens as well as microflora, which can lead to a decrease in local immunity and more favorable conditions for infection spread. The most physiologically safe and promising method for the restoration of vaginal biocenosis is the use of probiotics administered by a vaginal route.Methods. We have allocated 64 of cultures of Lactobacillus from the vaginal epithelium of healthy women of reproductive age and women with diagnosed bacterial vaginosis (BV. Identification of cultures was performed by PCR analysis of 16S ribosomal RNA.  Evaluation of biological significance was determined by the following criteria: high antagonistic activity against Candida albicans, Escherichia coli, Serratia marcescens, Proteus mirabilis, Klebsiella ozaenae, and Staphylococcus aureus; and production of hydrogen peroxide, resistance to antibiotics, adhesive activity. We studied the symbiotic relationship of selected biologically active of cultures to each other and received options for consortiums with  properties of  probiotics through co-cultivation.Results. Results of genotyping  showed that the isolated lactobacilli belong to the seven species: L. fermentum, L. salivarius, L. gasseri, L. crispatus, L. jensenii, L. plantarum, and L. delbrueskii. L. fermentum, L. salivarius, L. gasseri, and L. jensenii occur in women with suspected BV. The highest percentage of occurrence in the vagina of healthy women was L. fermentum (28%. Most strains of lactobacilli possess high inhibitory activity for all test-strains, except Candida albicans (37.5%. 56% of studied cultures revealed high adhesion to human erythrocytes. All lactobacillus strains were resistant to metronidazole, 80% to kanamycin, 57%  to vancomycin, and

  12. Use of vaginal estrogen in Danish women

    DEFF Research Database (Denmark)

    Meaidi, Amani; Goukasian, Irina; Lidegaard, Oejvind

    2016-01-01

    INTRODUCTION: We know little about the use of vaginal estrogen in perimenopausal and postmenopausal women. We aimed to assess the prevalence of vaginal estrogen use in Denmark. MATERIAL AND METHODS: The study was designed as a nationwide cross-sectional study of all Danish women aged 40-79 years......, living in Denmark during the period 2007-2013. The Danish Prescription Register delivered data permitting us to assess the prevalence, age and regional geographical belonging of women purchasing prescribed vaginal estradiol. The number of women using over-the-counter vaginal estriol products...... was estimated from sale statistics from the same register. RESULTS: In 2013, 10.2% of all Danish women between 40 and 79 years of age used vaginal estradiol. The prevalence of women using this type of vaginal estrogen increased from 8.5% in year 2007 to 10.2% in 2013. The use peaked at 16.5% in women aged 60...

  13. Radiation tolerance of the vaginal mucosa

    International Nuclear Information System (INIS)

    Hintz, b.L.; Kagan, A.R.; Chan, P.; Gilbert, H.A.; Nussbaum, H.; Rao, A.R.; Wollin, M.

    1980-01-01

    Sixteen patients with cancer of the vagina that were controlled locally for a minimum of eighteen months after teletherpay (T) or brachytherapy (B) or both (T and B), were analyzed for radiation tolerance of the vaginal mucosa. The site of vaginal necrosis did not always coincide with the site of the tumor. The posterior wall appeared more vulnerable than the anterior or lateral walls. For the distal vaginal mucosa, necrosis requiring surgical intervention occurred following combined T and B, if summated rad exceeded9800. The upper vagina tolerated higher dosages. No patient surgery for upper vaginal necrosis even though summated (T and B) dosage up to 14,000 rad was applied. Placing radioactive needles on the surface of the vaginal cylinder with or without interstitial perincal needles should be avoided. Further accumulation of data is needed to define these vaginal mucosa tolerance limits more closely

  14. Bacterial vaginosis and vaginal yeast, but not vaginal cleansing, increase HIV-1 acquisition in African women

    NARCIS (Netherlands)

    van de Wijgert, Janneke H. H. M.; Morrison, Charles S.; Cornelisse, Peter G. A.; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A.; Padian, Nancy S.

    2008-01-01

    OBJECTIVE: To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. METHODS: A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women

  15. User Manual for the PROTEUS Mesh Tools

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Micheal A. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, Emily R [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-19

    PROTEUS is built around a finite element representation of the geometry for visualization. In addition, the PROTEUS-SN solver was built to solve the even-parity transport equation on a finite element mesh provided as input. Similarly, PROTEUS-MOC and PROTEUS-NEMO were built to apply the method of characteristics on unstructured finite element meshes. Given the complexity of real world problems, experience has shown that using commercial mesh generator to create rather simple input geometries is overly complex and slow. As a consequence, significant effort has been put into place to create multiple codes that help assist in the mesh generation and manipulation. There are three input means to create a mesh in PROTEUS: UFMESH, GRID, and NEMESH. At present, the UFMESH is a simple way to generate two-dimensional Cartesian and hexagonal fuel assembly geometries. The UFmesh input allows for simple assembly mesh generation while the GRID input allows the generation of Cartesian, hexagonal, and regular triangular structured grid geometry options. The NEMESH is a way for the user to create their own mesh or convert another mesh file format into a PROTEUS input format. Given that one has an input mesh format acceptable for PROTEUS, we have constructed several tools which allow further mesh and geometry construction (i.e. mesh extrusion and merging). This report describes the various mesh tools that are provided with the PROTEUS code giving both descriptions of the input and output. In many cases the examples are provided with a regression test of the mesh tools. The most important mesh tools for any user to consider using are the MT_MeshToMesh.x and the MT_RadialLattice.x codes. The former allows the conversion between most mesh types handled by PROTEUS while the second allows the merging of multiple (assembly) meshes into a radial structured grid. Note that the mesh generation process is recursive in nature and that each input specific for a given mesh tool (such as .axial

  16. Vulvovaginitis and vaginal discharge in general practice

    Science.gov (United States)

    Shannon, W.

    1975-01-01

    Ninety-four patients with vulvovaginitis and vaginal discharge were assessed clinically and had vaginal swabs taken in an effort to establish a definite diagnosis. A high incidence of fungous infection was found while there was a surprisingly low incidence of Trichomonal vaginitis. These findings vary markedly from recent surveys in other countries (Delaha et al. (1964); Gray and Barnes, 1965; Desai et al., 1966). PMID:1223281

  17. Vaginal rejuvenation using energy-based devices

    Directory of Open Access Journals (Sweden)

    Cheryl Karcher, MD

    2016-09-01

    Full Text Available Physiologic changes in a woman’s life, such as childbirth, weight fluctuations, and hormonal changes due to aging and menopause, may alter the laxity of the vaginal canal, damage the pelvic floor, and devitalize the mucosal tone of the vaginal wall. These events often lead to the development of genitourinary conditions such as stress urinary incontinence; vaginal atrophy; dryness; and physiologic distress affecting a woman’s quality of life, self-confidence, and sexuality. Various treatment modalities are currently available to manage these indications, varying from invasive vaginal surgery to more benign treatments like topical vaginal hormonal gels or hormone-replacement therapy. A new trend gaining momentum is the advent of energy-based devices for vaginal rejuvenation that apply thermal or nonthermal energy to the various layers of the vaginal tissue, stimulating collagen regeneration contracture of elastin fibers, neovascularization, and improved vaginal lubrication. This review aims to present the available technologies offering vaginal rejuvenation and the scientific evidence that underlines their safety and efficacy for this indication.

  18. Evaluation of common organisms causing vaginal discharge.

    Science.gov (United States)

    Khan, Shazia A; Amir, Fauzia; Altaf, Shagufta; Tanveer, Raazia

    2009-01-01

    Vaginal discharge is very common problem among females. Alteration in balance of normal vaginal organisms can cause the overgrowth of the bacteria that creates vaginal discharge. It is common among sexually active women yet there still remain gaps in our knowledge of this infectious disorder. To evaluate the frequency of bacterial vaginosis (BV), vaginal candidiasis (VC), vaginal trichomoniasis and Group B streptococcus in women complaining of vaginal discharge in our setup. A total of 100 women of reproductive age group with the complaint of vaginal discharge were included in the study. After filling proforma patients were examined by speculum examination and two high vaginal swabs (HVS) were collected aseptically from each patient. One swab was used for making wet mount for clue cells, pus cells and for motility of Trichomonas vaginalis. The other swab was used to check pH and Amine test. The growth was confirmed by Gram staining in each case. Gardnerrella vaginalis were isolated in 28%, Group B streptococcus in 5% and T. vaginolis in 4% of women. Gardnerella vaginalis causing BV is the most common cause of vaginal discharge in otherwise healthy women of reproductive age group in our setup.

  19. Release of Tenofovir from Carrageenan-Based Vaginal Suppositories

    Directory of Open Access Journals (Sweden)

    Toral Zaveri

    2014-07-01

    Full Text Available Microbicides are an active area of research for HIV prevention, being developed as a woman-initiated method of prevention during unprotected coitus. Along with safety and efficacy, assessing and improving compliance is a major area of research in microbicide development. We have produced microbicide prototypes in the form of semisoft vaginal suppositories prepared from carrageenan and conducted both qualitative and quantitative studies using these prototypes to determine the physical properties that drive acceptability and possibly adherence. In order to ensure that the suppositories function as effective drug delivery vehicles, we have conducted in vitro dissolution studies in water, vaginal simulant fluid (VSF and semen simulant fluid (SSF with suppositories loaded with the antiretroviral drug, tenofovir (TFV. TFV was released via diffusion and matrix erosion in water or by diffusion out of the matrix in VSF and SSF. Diffusion studies were conducted in two different volumes of VSF and SSF. The volume of VSF/SSF into which TFV diffused and the size of the suppositories determined the rate of diffusion from the suppositories. About 45%–50% of the encapsulated TFV diffused out of the suppositories within the first two hours, irrespective of suppository size, diffusion medium (VSF/SSF and the volume of medium. Prior work indicates that a short waiting period between insertion and coitus is highly desired by women; present data suggest our microbicide prototypes have rapid initial release followed by a slow release curve over the first 24 h.

  20. Dynamic Clinical Measurements of Voluntary Vaginal Contractions and Autonomic Vaginal Reflexes

    NARCIS (Netherlands)

    Broens, Paul M. A.; Spoelstra, Symen K.; Weijmar Schultz, Willibrord C. M.

    2014-01-01

    IntroductionThe vaginal canal is an active and responsive canal. It has pressure variations along its length and shows reflex activity. At present, the prevailing idea is that the vaginal canal does not have a sphincter mechanism. It is hypothesized that an active vaginal muscular mechanism exists

  1. The interaction between vaginal microbiota, cervical length, and vaginal progesterone treatment for preterm birth risk.

    Science.gov (United States)

    Kindinger, Lindsay M; Bennett, Phillip R; Lee, Yun S; Marchesi, Julian R; Smith, Ann; Cacciatore, Stefano; Holmes, Elaine; Nicholson, Jeremy K; Teoh, T G; MacIntyre, David A

    2017-01-19

    Preterm birth is the primary cause of infant death worldwide. A short cervix in the second trimester of pregnancy is a risk factor for preterm birth. In specific patient cohorts, vaginal progesterone reduces this risk. Using 16S rRNA gene sequencing, we undertook a prospective study in women at risk of preterm birth (n = 161) to assess (1) the relationship between vaginal microbiota and cervical length in the second trimester and preterm birth risk and (2) the impact of vaginal progesterone on vaginal bacterial communities in women with a short cervix. Lactobacillus iners dominance at 16 weeks of gestation was significantly associated with both a short cervix vaginal dysbiosis. A longitudinal characterization of vaginal microbiota (vaginal progesterone (400 mg/OD, n = 25) versus controls (n = 42). Progesterone did not alter vaginal bacterial community structure nor reduce L. iners-associated preterm birth (vaginal microbiota at 16 weeks of gestation is a risk factor for preterm birth, whereas L. crispatus dominance is protective against preterm birth. Vaginal progesterone does not appear to impact the pregnancy vaginal microbiota. Patients and clinicians who may be concerned about "infection risk" associated with the use of a vaginal pessary during high-risk pregnancy can be reassured.

  2. Voltammetry at micro-mesh electrodes

    Directory of Open Access Journals (Sweden)

    Wadhawan Jay D.

    2003-01-01

    Full Text Available The voltammetry at three micro-mesh electrodes is explored. It is found that at sufficiently short experimental durations, the micro-mesh working electrode first behaves as an ensemble of microband electrodes, then follows the behaviour anticipated for an array of diffusion-independent micro-ring electrodes of the same perimeter as individual grid-squares within the mesh. During prolonged electrolysis, the micro-mesh electrode follows that behaviour anticipated theoretically for a cubically-packed partially-blocked electrode. Application of the micro-mesh electrode for the electrochemical determination of carbon dioxide in DMSO electrolyte solutions is further illustrated.

  3. 22nd International Meshing Roundtable

    CERN Document Server

    Staten, Matthew

    2014-01-01

    This volume contains the articles presented at the 22nd International Meshing Roundtable (IMR) organized, in part, by Sandia National Laboratories and was held on Oct 13-16, 2013 in Orlando, Florida, USA.  The first IMR was held in 1992, and the conference series has been held annually since.  Each year the IMR brings together researchers, developers, and application experts in a variety of disciplines, from all over the world, to present and discuss ideas on mesh generation and related topics.  The technical papers in this volume present theoretical and novel ideas and algorithms with practical potential, as well as technical applications in science and engineering, geometric modeling, computer graphics and visualization.

  4. 21st International Meshing Roundtable

    CERN Document Server

    Weill, Jean-Christophe

    2013-01-01

    This volume contains the articles presented at the 21st International Meshing Roundtable (IMR) organized, in part, by Sandia National Laboratories and was held on October 7–10, 2012 in San Jose, CA, USA. The first IMR was held in 1992, and the conference series has been held annually since. Each year the IMR brings together researchers, developers, and application experts in a variety of disciplines, from all over the world, to present and discuss ideas on mesh generation and related topics. The technical papers in this volume present theoretical and novel ideas and algorithms with practical potential, as well as technical applications in science and engineering, geometric modeling, computer graphics, and visualization.

  5. Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse

    Directory of Open Access Journals (Sweden)

    Naoko Takazawa

    2018-03-01

    Full Text Available Purpose: This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP. Materials and Methods: This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS and prolapse quality of life questionnaire (P-QOL and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Results: Prolapse recurred in 10 of 91 patients (11.0%, and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2% and pelvic pain in one (1.1% of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Conclusions: Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP.

  6. Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse.

    Science.gov (United States)

    Takazawa, Naoko; Fujisaki, Akiko; Yoshimura, Yasukuni; Tsujimura, Akira; Horie, Shigeo

    2018-03-01

    This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q) stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS) and prolapse quality of life questionnaire (P-QOL) and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Prolapse recurred in 10 of 91 patients (11.0%), and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2%) and pelvic pain in one (1.1%) of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP.

  7. Postoperative Urinary Retention and Urinary Tract Infections Predict Midurethral Sling Mesh Complications.

    Science.gov (United States)

    Punjani, Nahid; Winick-Ng, Jennifer; Welk, Blayne

    2017-01-01

    To determine if postoperative urinary retention and urinary tract infections (UTIs) were predictors of future mesh complications requiring surgical intervention after midurethral sling (MUS). Administrative data in Ontario, Canada, between 2002 and 2013 were used to identify all women who underwent a mesh-based MUS. The primary outcome was revision of the transvaginal mesh sling (including mesh removal/erosion/fistula, or urethrolysis). Two potential risk factors were analyzed: postoperative retention (within 30 days of procedure) and number of postoperative emergency room visits or hospital admissions for UTI symptoms. A total of 59,556 women had a MUS, of which 1598 (2.7%) required revision surgery. Of the 2025 women who presented to the emergency room or were admitted to hospital for postoperative retention, 212 (10.5%) required operative mesh revision. Of the 11,747 patients who had at least one postoperative UTI, 366 (3.1%) patients required operative mesh revision. In adjusted analysis, postoperative retention was significantly predictive of future reoperation (hazard ratio [HR] 3.46, 95% confidence interval [CI] 2.97-4.02), and this difference persisted when urethrolysis was excluded as a reason for sling revision (HR 3.08, 95% CI 2.62-3.63). Similarly, in adjusted analysis, each additional postoperative hospital visit for UTI symptoms increased the risk for surgical intervention for mesh complications (HR 1.74, 95% CI 1.61-1.87). Postoperative urinary retention and hospital presentation for UTI symptoms are associated with an increased risk of reoperation for MUS complications. These patients should be followed and investigated for mesh complications when appropriate. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Erosion of dust aggregates

    NARCIS (Netherlands)

    Seizinger, A.; Krijt, S.; Kley, W.

    2013-01-01

    Aims: The aim of this work is to gain a deeper insight into how much different aggregate types are affected by erosion. Especially, it is important to study the influence of the velocity of the impacting projectiles. We also want to provide models for dust growth in protoplanetary disks with simple

  9. Hydrology and soil erosion

    Science.gov (United States)

    Leonard J. Lane; Mary R. Kidwell

    2003-01-01

    We review research on surface water hydrology and soil erosion at the Santa Rita Experimental Range (SRER). Almost all of the research was associated with eight small experimental watersheds established from 1974 to 1975 and operated until the present. Analysis of climatic features of the SRER supports extending research findings from the SRER to broad areas of the...

  10. Bentonite erosion. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Birgersson, Martin; Boergesson, Lennart; Hedstroem, Magnus; Karnland, Ola; Nilsson, Ulf (Clay Technology AB, Lund (Sweden))

    2009-12-15

    Low saline water may reach KBS-3 repository depth, e.g. during periods of glaciation. Under such aqueous conditions, the montmorillonite part of the bentonite buffer might transform into a sol and thereby be transported away with flowing water in fractures. The primary aim with this report is to improve the understanding of the basic principles for this possible montmorillonite particle release. The report includes experimental and theoretical work performed at Clay Technology. Natural bentonite and ion-exchanged purified montmorillonite from three different geographical origins, Wyoming (U.S.), Milos (Greece) and Kutch (India) have been studied. Experimental and/or theoretical investigations have been performed with respect to: - Free swelling ability; - Rheological properties; - Rate of bentonite loss into fractures; - Filtering; - Ion exchange; - Sol formation ability; - Ion diffusion; - Mass loss due to erosion. The performed erosion experiments show that erosion does not occur in a mixed calcium/sodium montmorillonite with at least 20% calcium in exchange positions, when the external solution contains above 4 mM charge equivalents. This result is in agreement with the presented conceptual view of sol formation and measured equilibrium properties in mixed calcium/sodium montmorillonite. The findings imply that the buffer will be stable for non-glacial conditions. However, erosion due to sol formation cannot be ruled out for glacial conditions.

  11. Erosion scenarios for Wellenberg

    International Nuclear Information System (INIS)

    Klemenz, W.

    1993-09-01

    The proposed Wellenberg site for a radioactive waste repository is located between Altzellen in the Engelberger valley and the Oberrickenbach valley, in a thick Valanginian marl series. The marl is generally overlaid with unconsolidated rocks but reaches to the surface in some places. In contrast to the situation in the Oberbauenstock region this marl complex is not protected by an overlying erosion resistant series and exhibits a marked relief. The question therefore arises with respect to the Wellenberg site, to what extent will the marl (i.e. the repository host rock formation) be removed by erosion processes during the 100,000 years interval under consideration and what overburden will remain at the end of this period. This report presents the results of an investigation of the longterm behaviour of the proposed site in respect of those processes of erosion and deposition which can lead to changes in the terrain surface and its location relative to the repository. A wide range of possible scenarios encompassing different developments of climatic conditions during the 100,000 year period of interest, was investigated. In addition to the continuation of the present climate and the occurrence of a new ice age on the scale of the Wuerm glaciation the consequences of altered climatic conditions on erosion removal of the repository overburden were considered. Within the 100,000 year period of interest none of the scenarios considered leads to the exposure of the repository. (author) figs., tabs, refs

  12. Dune erosion above revetments

    NARCIS (Netherlands)

    Van Thiel de Vries, J.S.M.

    2012-01-01

    In a situation with a narrow dune, the dune base can be protected with a revetment to reduce dune erosion during extreme events. To quantify the effects of a revetment on storm impact, the functionality of the numerical storm impact model XBeach (Roelvink et al., 2009) is extended to account for the

  13. Bentonite erosion. Final report

    International Nuclear Information System (INIS)

    Birgersson, Martin; Boergesson, Lennart; Hedstroem, Magnus; Karnland, Ola; Nilsson, Ulf

    2009-12-01

    Low saline water may reach KBS-3 repository depth, e.g. during periods of glaciation. Under such aqueous conditions, the montmorillonite part of the bentonite buffer might transform into a sol and thereby be transported away with flowing water in fractures. The primary aim with this report is to improve the understanding of the basic principles for this possible montmorillonite particle release. The report includes experimental and theoretical work performed at Clay Technology. Natural bentonite and ion-exchanged purified montmorillonite from three different geographical origins, Wyoming (U.S.), Milos (Greece) and Kutch (India) have been studied. Experimental and/or theoretical investigations have been performed with respect to: - Free swelling ability; - Rheological properties; - Rate of bentonite loss into fractures; - Filtering; - Ion exchange; - Sol formation ability; - Ion diffusion; - Mass loss due to erosion. The performed erosion experiments show that erosion does not occur in a mixed calcium/sodium montmorillonite with at least 20% calcium in exchange positions, when the external solution contains above 4 mM charge equivalents. This result is in agreement with the presented conceptual view of sol formation and measured equilibrium properties in mixed calcium/sodium montmorillonite. The findings imply that the buffer will be stable for non-glacial conditions. However, erosion due to sol formation cannot be ruled out for glacial conditions.

  14. Adaptive Mesh Refinement in CTH

    International Nuclear Information System (INIS)

    Crawford, David

    1999-01-01

    This paper reports progress on implementing a new capability of adaptive mesh refinement into the Eulerian multimaterial shock- physics code CTH. The adaptivity is block-based with refinement and unrefinement occurring in an isotropic 2:1 manner. The code is designed to run on serial, multiprocessor and massive parallel platforms. An approximate factor of three in memory and performance improvements over comparable resolution non-adaptive calculations has-been demonstrated for a number of problems

  15. Categorization of erosion control matting.

    Science.gov (United States)

    2012-05-29

    Erosion control is a critical aspect of any Georgia Department of Transportation (GDOT) : construction project, with the extreme negative impacts of high sediment loads in natural : waterways having been well documented. A variety of erosion control ...

  16. Update on laparoscopic, robotic, and minimally invasive vaginal surgery for pelvic floor repair.

    Science.gov (United States)

    Ross, J W; Preston, M R

    2009-06-01

    Advanced laparoscopic surgery marked the beginning of minimally invasive pelvic surgery. This technique lead to the development of laparoscopic hysterectomy, colposuspension, paravaginal repair, uterosacral suspension, and sacrocolpopexy without an abdominal incision. With laparoscopy there is a significant decrease in postoperative pain, shorter length of hospital stay, and a faster return to normal activities. These advantages made laparoscopy very appealing to patients. Advanced laparoscopy requires a special set of surgical skills and in the early phase of development training was not readily available. Advanced laparoscopy was developed by practicing physicians, instead of coming down through the more usual academic channels. The need for special training did hinder widespread acceptance. Nonetheless by physician to physician training and society training courses it has continued to grow and now has been incorporated in most medical school curriculums. In the last few years there has been new interest in laparoscopy because of the development of robotic assistance. The 3D vision and 720 degree articulating arms with robotics have made suture intensive procedures much easier. Laparosco-pic robotic-assisted sacrocolpopexy is in the reach of most surgeons. This field is so new that there is very little data to evaluate at this time. There are short comings with laparoscopy and even with robotic-assisted procedures it is not the cure all for pelvic floor surgery. Laparoscopic procedures are long and many patients requiring pelvic floor surgery have medical conditions preventing long anesthesia. Minimally invasive vaginal surgery has developed from the concept of tissue replacement by synthetic mesh. Initially sheets of synthetic mesh were tailored by physicians to repair the anterior and posterior vaginal compartment. The use of mesh by general surgeons for hernia repair has served as a model for urogynecology. There have been rapid improvements in biomaterials

  17. Vaginal contraception--an update.

    Science.gov (United States)

    Edelman, D A; Thompson, S

    1982-04-01

    A number of new and innovative methods of vaginal contraceptive have been developed in recent years and are currently being evaluated. Some of these methods are described briefly and the available data on their safety and efficacy are presented. 3 types of contraceptive sponges have been developed--collagen sponge, intravaginal insert, and Secure sponge--and are now being evaluated. The collagen sponge, a cylindrical-shaped disk, exerts its contraceptive effect by acting as a physical barrier to the sperm and through its ability to absorb semen much in excess of its own weight. Preliminary data confirm the effectiveness of the sponge obtained from post-coital tests. The intravaginal insert (IVI) is made of a polyester material incorporating the spermicide nonoxynol-9. In a small clinical evaluation of the IVI, 49 women were followed up for 1 month. No pregnancies or unexpected adverse reactions were reported. The Secure sponge is made of polyurethane and incorporates 1 g of the spermicide nonoxynol-9. Its primary mode of action in preventing pregnancy is through the release of nonoxynol-9. In a multiclinic phase 2 evaluation of the Secure, which included 382 women, the 6-month gross life-table pregnancy rate was 3.8 +or- 1.3/100 women; the 6-month gross discontinuation rate for all reasons was 26.2 +or- 3.4/100 women. Sufficient data from the comparative trials of the Secure and Neo Sampoon foaming suppository studies conducted in Yugoslavia, Taiwan, and Bangladesh have been reported to the International Fertility Research Program (IFRP). The 12-month life-table rates for reasons leading to discontinuation of the contraceptive methods were not significantly different except for the category of "other personal reasons." The advantages Secure provides over other vaginal contraceptives are identified. Foaming vaginal suppositories similar to Neo Sampoon but containing 100 mg nonoxynol-9 are being developed and evaluated in the U.S. Clinical data on these products are

  18. More frequent vaginal orgasm is associated with experiencing greater excitement from deep vaginal stimulation.

    Science.gov (United States)

    Brody, Stuart; Klapilova, Katerina; Krejčová, Lucie

    2013-07-01

    Research indicated that: (i) vaginal orgasm (induced by penile-vaginal intercourse [PVI] without concurrent clitoral masturbation) consistency (vaginal orgasm consistency [VOC]; percentage of PVI occasions resulting in vaginal orgasm) is associated with mental attention to vaginal sensations during PVI, preference for a longer penis, and indices of psychological and physiological functioning, and (ii) clitoral, distal vaginal, and deep vaginal/cervical stimulation project via different peripheral nerves to different brain regions. The aim of this study is to examine the association of VOC with: (i) sexual arousability perceived from deep vaginal stimulation (compared with middle and shallow vaginal stimulation and clitoral stimulation), and (ii) whether vaginal stimulation was present during the woman's first masturbation. A sample of 75 Czech women (aged 18-36), provided details of recent VOC, site of genital stimulation during first masturbation, and their recent sexual arousability from the four genital sites. The association of VOC with: (i) sexual arousability perceived from the four genital sites and (ii) involvement of vaginal stimulation in first-ever masturbation. VOC was associated with greater sexual arousability from deep vaginal stimulation but not with sexual arousability from other genital sites. VOC was also associated with women's first masturbation incorporating (or being exclusively) vaginal stimulation. The findings suggest (i) stimulating the vagina during early life masturbation might indicate individual readiness for developing greater vaginal responsiveness, leading to adult greater VOC, and (ii) current sensitivity of deep vaginal and cervical regions is associated with VOC, which might be due to some combination of different neurophysiological projections of the deep regions and their greater responsiveness to penile stimulation. © 2013 International Society for Sexual Medicine.

  19. Vaginal hysterectomy, an outpatient procedure.

    Science.gov (United States)

    Engh, Marie Ellström; Hauso, Wenche

    2012-11-01

    To report our experience of treating women undergoing vaginal hysterectomy in an outpatient setting and to identify risk factors for hospital admission and women dissatisfied with care. Prospective observational report. department of obstetrics and gynecology, university hospital in Norway. 150 women who underwent vaginal hysterectomy at the outpatient clinic from February 2009 to April 2010. Perioperative data were collected prospectively and case notes were searched for complications. On the first postoperative day all women were contacted by telephone by a nurse. A visual analogue scale (VAS) was used to monitor pain and nausea during the stay at the outpatient clinic and the day after surgery. VAS was also used to specify the women's degree of satisfaction with care the day after surgery. The number of women who could be discharged from the outpatient unit and had a satisfaction score of ≥7 the day after surgery. Of the 150 women, 84% could be discharged after a mean observation period of 276 min (SD ± 80 min). The mean satisfaction score was 9.0, SD ± 1.4, and 92.6% of the women reported ≥7 points in the satisfaction score. No women with serious complications were sent home. Using a multivariable logistic regression model only pain at discharge was found as significant (p= 0.009) for admittance to hospital. Vaginal hysterectomy is a feasible outpatient procedure and the majority of women were satisfied with the care they received. © 2012 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2012 Nordic Federation of Societies of Obstetrics and Gynecology.

  20. Obturator Neuralgia: A Rare Complication of Tension-free Vaginal Tape Sling-Complete Resolution After Laparoscopic Tension-free Vaginal Tape Removal.

    Science.gov (United States)

    Miklos, John R; Moore, Robert D; Chinthakanan, Orawee

    2015-01-01

    To show a technique of retropubic tension-free vaginal tape (TVT) removal using both a transvaginal and laparoscopic approach in the treatment of a rare condition, obturator neuralgia. A step-by-step explanation of the patient's condition, diagnosis, surgical technique, and postoperative results using video, pictures, and medical illustrations (education video). TVT retropubic slings have become the gold standard for the treatment of stress urine incontinence over the last decade. Despite high cure rates, the TVT is not without potential complications. Typical complications include urine retention, incomplete bladder emptying, frequency, urgency, urethral erosion, vaginal extrusion, vaginal pain, and dyspareunia. The most common complication for sling removal/revision is chronic pain. The TVT obturator neuralgia is a rare and specific type of chronic pain that is normally associated with transobturator tape slings. The purpose of this video is to present an extremely rare complication of TVT retropubic slings, present symptoms and signs of obturator nerve compression, show the normal and the actual position of this patient's TVT sling, describe the laparoscopic removal of the TVT sling, and present the postoperative course and resolution of the patient's pain. The patient signed a release for her video to be used for educational and teaching purposes. A combined transvaginal and laparoscopic approach in a patient with lower abdominal, levator, and obturator-type pain after a TVT retropubic procedure. In patients suffering from obturator neuralgia after a retropubic sling, surgeons should include the sling as a potential causative factor in the differential diagnosis. Surgeons should consider removing the sling based on the patient's symptoms. If the patient suffers from only vaginal pain and dyspareunia, then the surgeon should consider only the removal of the vaginal portion of the sling. In patients with obturator neuralgia, retropubic, and/or lower abdominal

  1. Descriptiveness of vaginal secretions pH in the vaginal microbiota assessment in pregnant women

    Directory of Open Access Journals (Sweden)

    V. F. Nagornaya

    2016-07-01

    2 KU maternity hospital №7, Odessa           Summary 143 pregnant and 20 non-pregnant women have been examined. The objective: to determine the information content of  the vaginal fluid pH.  Methods used: Cytological, standard microbiological,  real time PCR, the measurement of vaginal fluid pH. Results: five types  of vaginal microbiota have been revealed, as well as a clear link of pH and the quantitative characteristic of microflora, high inverse correlation with  estradiol content was shown,  and correspondence to the number of gestation complications and the number of inflammatory diseases of the somatic plan was proved. The authors recommend to use pH of the vaginal fluid as an indicator of the state of vaginal biotope in the course of pregnancy.       Keywords: pH of the vaginal secretion, vaginal biotope pregnancy.

  2. Reoccurrence of retained placenta at vaginal delivery

    DEFF Research Database (Denmark)

    Nikolajsen, Sys; Løkkegaard, Ellen Christine Leth; Bergholt, Thomas

    2013-01-01

    To estimate the prevalence and validate the diagnosis of retained placenta in nulliparous women and the risk of reoccurrence at subsequent vaginal delivery.......To estimate the prevalence and validate the diagnosis of retained placenta in nulliparous women and the risk of reoccurrence at subsequent vaginal delivery....

  3. Use of vaginal hysterectomy in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Sidsel Lykke; Daugbjerg, Signe B; Gimbel, Helga

    2011-01-01

    To describe the use of vaginal, abdominal and laparoscopic hysterectomy in Denmark from 1999 to 2008, the influence of national guidelines and the patient and procedure-related characteristics associated with the choice of vaginal hysterectomy. Design. Nationwide register-based cohort study....

  4. VULVO-VAGINAL CANDIDIASIS ASSOCIATED WITH ACITRETIN

    NARCIS (Netherlands)

    STURKENBOOM, MCJM; MIDDELBEEK, A; VANDENBERG, LTWD; VANDENBERG, PB; STRICKER, BHC; WESSELING, H

    The aim of this study was to estimate the risk of vulvo-vaginal candidiasis among the users of acitretin. The incidence rate ratio of vulvo-vaginal candidiasis was estimated in a cohort of acitretin users by using prescription sequence analysis. Study subjects were 196 women between 15 and 45 years

  5. Short convalescence after vaginal prolapse surgery

    DEFF Research Database (Denmark)

    Ottesen, Marianne; Sørensen, Mette; Kehlet, Henrik

    2003-01-01

    OBJECTIVE: Retrospectively to describe the recommended convalescence according to patients who had undergone vaginal prolapse surgery in 1996-98, and prospectively to describe the need for and limiting factors for convalescence after vaginal prolapse surgery in 1999-2000 at a Danish University Ho...

  6. 21 CFR 884.3900 - Vaginal stent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to...

  7. Long-term outcome after transvaginal mesh repair of pelvic organ prolapse.

    Science.gov (United States)

    Heinonen, Pia; Aaltonen, Riikka; Joronen, Kirsi; Ala-Nissilä, Seija

    2016-07-01

    The aim of this study was to report long-term subjective and objective outcomes after the transvaginal mesh (TVM) procedure in long-term. Possible late-onset complications were of particular interest. This was a retrospective analysis of TVM performed using Prolift™ transvaginal mesh measuring subjective outcome using validated questionnaires. Objective outcome was assessed using the Pelvic Organ Prolapse Quantification (POP-Q) system using two definitions: POP-Q stage ≤ 1, and vaginal wall prolapse at or above the hymen or vaginal apex not descending below the upper third of the vagina. Complications were reported with the Prosthesis/Graft Complication Classification Code designed by the International Continence Society/International Urogynecological Association (ICS/IUGA). Of 195 patients, 161 (82.6 %) participated this study after a median of 7 years. The scores in questionnaires evaluating urinary (UI) or anal incontinence and constipation or pelvic floor symptoms were low, indicating favorable surgical outcomes. Altogether, 80.1 % of patients were satisfied with the procedure. Anatomical cure was 56.4 % and 69.3 % depending on the definition used. Reoperation due to POP in any compartment was performed in 16.2 % of patients. Mesh exposure rate was 23 %, most of these being asymptomatic and of late onset. Outcome of the TVM procedure was satisfactory. Anatomical cure was inferior to subjective cure. Mesh exposure rate was high; most exposures observed in the long-term were of late onset and were asymptomatic.

  8. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections

    Directory of Open Access Journals (Sweden)

    Nenadić Dane

    2015-01-01

    Full Text Available Bacground/Aim. Vaginal and cervical swab culture is still very common procedure in our country’s everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM, vaginal pH and potassium hydroxide (KOH test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. Methods. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. Results. In 36 (6% patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11% women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19% women had BV, 19 (4% vaginitis, and 72 (14% candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21% had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30% women - in 83 (54% of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Conclusion. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal

  9. Value of bacterial culture of vaginal swabs in diagnosis of vaginal infections.

    Science.gov (United States)

    Nenadić, Dane; Pavlović, Miloš D

    2015-06-01

    Vaginal and cervical swab culture is still very common procedure in our country's everyday practice whereas simple and rapid diagnostic methods have been very rarely used. The aim of this study was to show that the employment of simple and rapid diagnostic tools [vaginal fluid wet mount microscopy (VFWMM), vaginal pH and potassium hydroxide (KOH) test] offers better assessment of vaginal environment than standard microbiologic culture commonly used in Serbia. This prospective study included 505 asymptomatic pregnant women undergoing VFWMM, test with 10% KOH, determination of vaginal pH and standard culture of cervicovaginal swabs. Combining findings from the procedures was used to make diagnoses of bacterial vaginosis (BV) and vaginitis. In addition, the number of polymorphonuclear leukocytes (PMN) was determined in each sample and analyzed along with other findings. Infections with Candida albicans and Trichomonas vaginalis were confirmed or excluded by microscopic examination. In 36 (6%) patients cervicovaginal swab cultures retrieved several aerobes and facultative anaerobes, whereas in 52 (11%) women Candida albicans was isolated. Based on VFWMM findings and clinical criteria 96 (19%) women had BV, 19 (4%) vaginitis, and 72 (14%) candidiasis. Of 115 women with BV and vaginitis, pH 4.5 was found in 5, and of 390 with normal findings 83 (21%) had vaginal pH 4.5. Elevated numbers of PMN were found in 154 (30%) women--in 83 (54%) of them VFWMM was normal. Specificity and sensitivity of KOH test and vaginal pH determination in defining pathological vaginal flora were 95% and 81%, and 79% and 91%, respectively. Cervicovaginal swab culture is expensive but almost non-informative test in clinical practice. The use of simpler and rapid methods as vaginal fluid wet mount microscopy, KOH test and vaginal pH offers better results in diagnosis, and probably in the treatment and prevention of sequels of vaginal infections.

  10. [Severe vaginal discharge following rectal surgery].

    Science.gov (United States)

    Burg, L C; Bremers, A J A; Heesakkers, J P F A; Kluivers, K B

    2018-01-01

    Almost 50% of women who have had rectal surgery subsequently develop vaginal discharge. Due to the recurrent and unexpected nature of this heavy discharge, they often experience it as very distressing. Many of these women undergo extensive diagnostic tests that are mainly focused on identifying fistula formation. If no fistula is found, in most cases no other cause for severe vaginal discharge can be demonstrated. In our practice, we saw three patients (49-, 54- and 74-years-old, respectively) with similar severe vaginal discharge after rectal surgery and in whom no explanation for the vaginal discharge could be found. For this reason we conducted a literature search into this condition. Anatomical changes appear to be responsible for heavy vaginal discharge following rectal surgery. Changes in pelvic floor muscles and compression of the distal part of the vagina may lead to pooling of fluid in the proximal part of the vagina, resulting in severe discharge. Symptomatic treatment may reduce the symptoms.

  11. Laparoscopic appendicectomy for suspected mesh-induced appendicitis after laparoscopic transabdominal preperitoneal polypropylene mesh inguinal herniorraphy

    Directory of Open Access Journals (Sweden)

    Jennings Jason

    2010-01-01

    Full Text Available Laparoscopic inguinal herniorraphy via a transabdominal preperitoneal (TAPP approach using Polypropylene Mesh (Mesh and staples is an accepted technique. Mesh induces a localised inflammatory response that may extend to, and involve, adjacent abdominal and pelvic viscera such as the appendix. We present an interesting case of suspected Mesh-induced appendicitis treated successfully with laparoscopic appendicectomy, without Mesh removal, in an elderly gentleman who presented with symptoms and signs of acute appendicitis 18 months after laparoscopic inguinal hernia repair. Possible mechanisms for Mesh-induced appendicitis are briefly discussed.

  12. Removal of Polypropylene Sling Mesh From the Urethra: An Anatomic Technique.

    Science.gov (United States)

    Freilich, Drew A; Rovner, Eric S

    2015-07-01

    To describe a technique for removal of intraurethral mesh with minimal disruption of the periurethral anatomy. Through a midline transvaginal approach the sling is located lateral to the urethra and divided. The medial portion of the divided sling is carefully dissected back to its entrance laterally into the urethral lumen. A stay suture is placed on the dissected sling. The sling is located on the contralateral side and likewise divided and dissected back to the urethral lumen. The completely dissected sling is pulled through such that the holding stitch is through and through the urethral lumen, allowing easy localization of the urethral defect on lateral walls of the urethra. These defects are closed with an absorbable suture and the vaginal incision is closed. Three patients have undergone a transvaginal removal of their intraurethral mesh using the described technique. At a mean follow-up of 6.0 months, there were no intraoperative or postoperative complications. All patients were obstructed preoperatively and all developed stress urinary incontinence postoperatively requiring 0-1 pads per day. Current approaches to the surgical repair of chronic intraurethral mesh have significant limitations that are minimized by the described technique. This anatomic removal of mesh from the urethra has several advantages including no disruption of the ventral wall of the urethra, complete removal of foreign body from the urethra, and simplified localization of the urethral wall defect to allow for anatomic closure. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Rainfall erosivity map for Ghana

    International Nuclear Information System (INIS)

    Oduro Afriyie, K.

    1995-10-01

    Monthly rainfall data, spanning over a period of more than thirty years, were used to compute rainfall erosivity indices for various stations in Ghana, using the Fournier index, c, defined as p 2 /P, where p is the rainfall amount in the wettest month and P is the annual rainfall amount. Values of the rainfall erosivity indices ranged from 24.5 mm at Sunyani in the mid-portion of Ghana to 180.9 mm at Axim in the south western coastal portion. The indices were used to construct a rainfall erosivity map for the country. The map revealed that Ghana may be broadly divided into five major erosion risk zones. The middle sector of Ghana is generally in the low erosion risk zone; the northern sector is in the moderate to severe erosion risk zone, while the coastal sector is in the severe to extreme severe erosion risk zone. (author). 11 refs, 1 fig., 1 tab

  14. Sierra toolkit computational mesh conceptual model

    International Nuclear Information System (INIS)

    Baur, David G.; Edwards, Harold Carter; Cochran, William K.; Williams, Alan B.; Sjaardema, Gregory D.

    2010-01-01

    The Sierra Toolkit computational mesh is a software library intended to support massively parallel multi-physics computations on dynamically changing unstructured meshes. This domain of intended use is inherently complex due to distributed memory parallelism, parallel scalability, heterogeneity of physics, heterogeneous discretization of an unstructured mesh, and runtime adaptation of the mesh. Management of this inherent complexity begins with a conceptual analysis and modeling of this domain of intended use; i.e., development of a domain model. The Sierra Toolkit computational mesh software library is designed and implemented based upon this domain model. Software developers using, maintaining, or extending the Sierra Toolkit computational mesh library must be familiar with the concepts/domain model presented in this report.

  15. Anisotropic evaluation of synthetic surgical meshes.

    Science.gov (United States)

    Saberski, E R; Orenstein, S B; Novitsky, Y W

    2011-02-01

    The material properties of meshes used in hernia repair contribute to the overall mechanical behavior of the repair. The anisotropic potential of synthetic meshes, representing a difference in material properties (e.g., elasticity) in different material axes, is not well defined to date. Haphazard orientation of anisotropic mesh material can contribute to inconsistent surgical outcomes. We aimed to characterize and compare anisotropic properties of commonly used synthetic meshes. Six different polypropylene (Trelex(®), ProLite™, Ultrapro™), polyester (Parietex™), and PTFE-based (Dualmesh(®), Infinit) synthetic meshes were selected. Longitudinal and transverse axes were defined for each mesh, and samples were cut in each axis orientation. Samples underwent uniaxial tensile testing, from which the elastic modulus (E) in each axis was determined. The degree of anisotropy (λ) was calculated as a logarithmic expression of the ratio between the elastic modulus in each axis. Five of six meshes displayed significant anisotropic behavior. Ultrapro™ and Infinit exhibited approximately 12- and 20-fold differences between perpendicular axes, respectively. Trelex(®), ProLite™, and Parietex™ were 2.3-2.4 times. Dualmesh(®) was the least anisotropic mesh, without marked difference between the axes. Anisotropy of synthetic meshes has been underappreciated. In this study, we found striking differences between elastic properties of perpendicular axes for most commonly used synthetic meshes. Indiscriminate orientation of anisotropic mesh may adversely affect hernia repairs. Proper labeling of all implants by manufacturers should be mandatory. Understanding the specific anisotropic behavior of synthetic meshes should allow surgeons to employ rational implant orientation to maximize outcomes of hernia repair.

  16. Protection against rat vaginal candidiasis by adoptive transfer of vaginal B lymphocytes.

    Science.gov (United States)

    De Bernardis, Flavia; Santoni, Giorgio; Boccanera, Maria; Lucciarini, Roberta; Arancia, Silvia; Sandini, Silvia; Amantini, Consuelo; Cassone, Antonio

    2010-06-01

    Vulvovaginal candidiasis is a mucosal infection affecting many women, but the immune mechanisms operating against Candida albicans at the mucosal level remain unknown. A rat model was employed to further characterize the contribution of B and T cells to anti-Candida vaginal protection. Particularly, the protective role of vaginal B cells was studied by means of adoptive transfer of vaginal CD3(-) CD5(+) IgM(+) cells from Candida-immunized rats to naïve animals. This passive transfer of B cells resulted into a number of vaginal C. albicans CFU approximately 50% lower than their controls. Sorted CD3(-) CD5(+) IgM(+) vaginal B lymphocytes from Candida-infected rats proliferated in response to stimulation with an immunodominant mannoprotein (MP) antigen of the fungus. Importantly, anti-MP antibodies and antibody-secreting B cells were detected in the supernatant and cell cultures, respectively, of vaginal B lymphocytes from infected rats incubated in vitro with vaginal T cells and stimulated with MP. No such specific antibodies were found when using vaginal B cells from uninfected rats. Furthermore, inflammatory and anti-inflammatory cytokines, such as interleukin-2 (IL-2), IL-6 and IL-10, were found in the supernatant of vaginal B cells from infected rats. These data are evidence of a partial anti-Candida protective role of CD3(-) CD5(+) IgM(+) vaginal B lymphocytes in our experimental model.

  17. Unstructured mesh adaptivity for urban flooding modelling

    Science.gov (United States)

    Hu, R.; Fang, F.; Salinas, P.; Pain, C. C.

    2018-05-01

    Over the past few decades, urban floods have been gaining more attention due to their increase in frequency. To provide reliable flooding predictions in urban areas, various numerical models have been developed to perform high-resolution flood simulations. However, the use of high-resolution meshes across the whole computational domain causes a high computational burden. In this paper, a 2D control-volume and finite-element flood model using adaptive unstructured mesh technology has been developed. This adaptive unstructured mesh technique enables meshes to be adapted optimally in time and space in response to the evolving flow features, thus providing sufficient mesh resolution where and when it is required. It has the advantage of capturing the details of local flows and wetting and drying front while reducing the computational cost. Complex topographic features are represented accurately during the flooding process. For example, the high-resolution meshes around the buildings and steep regions are placed when the flooding water reaches these regions. In this work a flooding event that happened in 2002 in Glasgow, Scotland, United Kingdom has been simulated to demonstrate the capability of the adaptive unstructured mesh flooding model. The simulations have been performed using both fixed and adaptive unstructured meshes, and then results have been compared with those published 2D and 3D results. The presented method shows that the 2D adaptive mesh model provides accurate results while having a low computational cost.

  18. Adaptive hybrid mesh refinement for multiphysics applications

    International Nuclear Information System (INIS)

    Khamayseh, Ahmed; Almeida, Valmor de

    2007-01-01

    The accuracy and convergence of computational solutions of mesh-based methods is strongly dependent on the quality of the mesh used. We have developed methods for optimizing meshes that are comprised of elements of arbitrary polygonal and polyhedral type. We present in this research the development of r-h hybrid adaptive meshing technology tailored to application areas relevant to multi-physics modeling and simulation. Solution-based adaptation methods are used to reposition mesh nodes (r-adaptation) or to refine the mesh cells (h-adaptation) to minimize solution error. The numerical methods perform either the r-adaptive mesh optimization or the h-adaptive mesh refinement method on the initial isotropic or anisotropic meshes to equidistribute weighted geometric and/or solution error function. We have successfully introduced r-h adaptivity to a least-squares method with spherical harmonics basis functions for the solution of the spherical shallow atmosphere model used in climate modeling. In addition, application of this technology also covers a wide range of disciplines in computational sciences, most notably, time-dependent multi-physics, multi-scale modeling and simulation

  19. Meshes optimized for discrete exterior calculus (DEC).

    Energy Technology Data Exchange (ETDEWEB)

    Mousley, Sarah C. [Univ. of Illinois, Urbana-Champaign, IL (United States); Deakin, Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Knupp, Patrick [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Mitchell, Scott A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    We study the optimization of an energy function used by the meshing community to measure and improve mesh quality. This energy is non-traditional because it is dependent on both the primal triangulation and its dual Voronoi (power) diagram. The energy is a measure of the mesh's quality for usage in Discrete Exterior Calculus (DEC), a method for numerically solving PDEs. In DEC, the PDE domain is triangulated and this mesh is used to obtain discrete approximations of the continuous operators in the PDE. The energy of a mesh gives an upper bound on the error of the discrete diagonal approximation of the Hodge star operator. In practice, one begins with an initial mesh and then makes adjustments to produce a mesh of lower energy. However, we have discovered several shortcomings in directly optimizing this energy, e.g. its non-convexity, and we show that the search for an optimized mesh may lead to mesh inversion (malformed triangles). We propose a new energy function to address some of these issues.

  20. RGG: Reactor geometry (and mesh) generator

    International Nuclear Information System (INIS)

    Jain, R.; Tautges, T.

    2012-01-01

    The reactor geometry (and mesh) generator RGG takes advantage of information about repeated structures in both assembly and core lattices to simplify the creation of geometry and mesh. It is released as open source software as a part of the MeshKit mesh generation library. The methodology operates in three stages. First, assembly geometry models of various types are generated by a tool called AssyGen. Next, the assembly model or models are meshed by using MeshKit tools or the CUBIT mesh generation tool-kit, optionally based on a journal file output by AssyGen. After one or more assembly model meshes have been constructed, a tool called CoreGen uses a copy/move/merge process to arrange the model meshes into a core model. In this paper, we present the current state of tools and new features in RGG. We also discuss the parallel-enabled CoreGen, which in several cases achieves super-linear speedups since the problems fit in available RAM at higher processor counts. Several RGG applications - 1/6 VHTR model, 1/4 PWR reactor core, and a full-core model for Monju - are reported. (authors)

  1. Parallel adaptive simulations on unstructured meshes

    International Nuclear Information System (INIS)

    Shephard, M S; Jansen, K E; Sahni, O; Diachin, L A

    2007-01-01

    This paper discusses methods being developed by the ITAPS center to support the execution of parallel adaptive simulations on unstructured meshes. The paper first outlines the ITAPS approach to the development of interoperable mesh, geometry and field services to support the needs of SciDAC application in these areas. The paper then demonstrates the ability of unstructured adaptive meshing methods built on such interoperable services to effectively solve important physics problems. Attention is then focused on ITAPs' developing ability to solve adaptive unstructured mesh problems on massively parallel computers

  2. Erosion-corrosion synergistics in the low erosion regime

    International Nuclear Information System (INIS)

    Corey, R.G.; Sethi, V.K.

    1986-01-01

    Many engineering alloys display good high temperature corrosion resistance. However, when they are used in corrosive environments where they are subjected to erosion also, the corrosion resistance has been adversely affected. The phenomenon known as erosion-corrosion is complex and requires detailed investigation of how the erosion and corrosion kinetics interact and compete. At the Kentucky Center for Energy Research Laboratory, an erosion-corrosion tester was used to perform erosion-oxidation tests on 2 1/4 Cr-1 Mo steel at 500-600 0 C using alumina abrasive at low velocities. The erosion-oxidation rate data and morphology of exposed surfaces are consistent with oxide chipping and fracturing being the mode of material loss

  3. Endometrial safety of ultra-low-dose estradiol vaginal tablets

    DEFF Research Database (Denmark)

    Simon, James; Nachtigall, Lila; Ulrich, Lian G

    2010-01-01

    To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17ß-estradiol vaginal tablets in postmenopausal women with vaginal atrophy.......To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17ß-estradiol vaginal tablets in postmenopausal women with vaginal atrophy....

  4. Endometrial safety of ultra-low-dose estradiol vaginal tablets

    DEFF Research Database (Denmark)

    Simon, James; Nachtigall, Lila; Ulrich, Lian G

    2010-01-01

    To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17β-estradiol vaginal tablets in postmenopausal women with vaginal atrophy.......To evaluate the endometrial hyperplasia and carcinoma rate after 52-week treatment with ultra-low-dose 10-microgram 17β-estradiol vaginal tablets in postmenopausal women with vaginal atrophy....

  5. A terminological matter: paragenesis, antigravitative erosion or antigravitational erosion ?

    Directory of Open Access Journals (Sweden)

    Pasini G.

    2009-07-01

    Full Text Available In the speleological literature three terms are utilized to designate the “ascending erosion”: paragenesis (= paragénésis, coined in1968, antigravitative erosion (= erosione antigravitativa, coined in 1966 and antigravitational erosion (wrong English translation ofthe Italian term erosione antigravitativa, utilized later on. The term paragenesis should be abandoned because of the priority of theterm erosione antigravitativa - on the ground of the “law of priority” – and because of its ambiguous etimology. On the other hand,the term antigravitational erosion should be forsaken in favour of the term antigravitative erosion, given the meaning that the termsgravitation and gravity have in Physics. Therefore, to designate the phenomenon of the “ascending erosion” there would be nothingleft but the term antigravitative erosion.The antigravitative erosion process and its recognizability are illustrated.Examples of caves with evident antigravitative erosion phenomena, developed in different karstifiable rocks and in several partsof the world, are given.It is recalled that the antigravitative erosion is a phenomenon well-known since 1942 and widely proven and supported, and that it isrelatively easy – in many cases - to recognize the antigravitative origin of karstic passages.It is stressed that the antigravitative erosion is an important phenomenon, exclusive of the karstic caves and unique in nature.

  6. Tensile Behaviour of Welded Wire Mesh and Hexagonal Metal Mesh for Ferrocement Application

    Science.gov (United States)

    Tanawade, A. G.; Modhera, C. D.

    2017-08-01

    Tension tests were conducted on welded mesh and hexagonal Metal mesh. Welded Mesh is available in the market in different sizes. The two types are analysed viz. Ø 2.3 mm and Ø 2.7 mm welded mesh, having opening size 31.75 mm × 31.75 mm and 25.4 mm × 25.4 mm respectively. Tensile strength test was performed on samples of welded mesh in three different orientations namely 0°, 30° and 45° degrees with the loading axis and hexagonal Metal mesh of Ø 0.7 mm, having opening 19.05 × 19.05 mm. Experimental tests were conducted on samples of these meshes. The objective of this study was to investigate the behaviour of the welded mesh and hexagonal Metal mesh. The result shows that the tension load carrying capacity of welded mesh of Ø 2.7 mm of 0° orientation is good as compared to Ø2.3 mm mesh and ductility of hexagonal Metal mesh is good in behaviour.

  7. Mesh optimization for microbial fuel cell cathodes constructed around stainless steel mesh current collectors

    KAUST Repository

    Zhang, Fang; Merrill, Matthew D.; Tokash, Justin C.; Saito, Tomonori; Cheng, Shaoan; Hickner, Michael A.; Logan, Bruce E.

    2011-01-01

    that the mesh properties of these cathodes can significantly affect performance. Cathodes made from the coarsest mesh (30-mesh) achieved the highest maximum power of 1616 ± 25 mW m-2 (normalized to cathode projected surface area; 47.1 ± 0.7 W m-3 based on liquid

  8. The Vaginal Microbiota and Urinary Tract Infection.

    Science.gov (United States)

    Stapleton, Ann E

    2016-12-01

    The vagina is a key anatomical site in the pathogenesis of urinary tract infection (UTI) in women, serving as a potential reservoir for infecting bacteria and a site at which interventions may decrease the risk of UTI. The vaginal microbiota is a dynamic and often critical factor in this pathogenic interplay, because changes in the characteristics of the vaginal microbiota resulting in the loss of normally protective Lactobacillus spp. increase the risk of UTI. These alterations may result from the influence of estrogen deficiency, antimicrobial therapy, contraceptives, or other causes. Interventions to reduce adverse effects on the vaginal microbiota and/or to restore protective lactobacilli may reduce the risks of UTI.

  9. Proinflammatory Cytokines as Regulators of Vaginal Microbiota.

    Science.gov (United States)

    Kremleva, E A; Sgibnev, A V

    2016-11-01

    It was shown that IL-1β, IL-8, and IL-6 in concentrations similar to those in the vagina of healthy women stimulated the growth of normal microflora (Lactobacillus spp.) and suppressed the growth and biofilm production by S. aureus and E. coli. On the contrary, these cytokines in higher concentrations typical of vaginal dysbiosis suppressed normal microflora and stimulated the growth of opportunistic microorganisms. TGF-β1 in both doses produced a stimulating effects on study vaginal microsymbionts. It is hypothesized that pro-inflammatory cytokines serve as the molecules of interspecies communication coordinating the interactions of all components of the vaginal symbiotic system.

  10. Vaginal rings for delivery of HIV microbicides.

    Science.gov (United States)

    Malcolm, R Karl; Fetherston, Susan M; McCoy, Clare F; Boyd, Peter; Major, Ian

    2012-01-01

    Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing.

  11. Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.

    Science.gov (United States)

    Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram

    2016-11-01

    Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.

  12. Directed shift of vaginal microbiota induced by vaginal application of sucrose gel in rhesus macaques

    OpenAIRE

    Hu, Kai-tao; Zheng, Jin-xin; Yu, Zhi-jian; Chen, Zhong; Cheng, Hang; Pan, Wei-guang; Yang, Wei-zhi; Wang, Hong-yan; Deng, Qi-wen; Zeng, Zhong-ming

    2015-01-01

    Objectives: Sucrose gel was used to treat bacterial vaginosis in a phase III clinical trial. However, the changes of vaginal flora after treatment were only examined by Nugent score in that clinical trial, While the vaginal microbiota of rhesus macaques is characterized by anaerobic, Gram-negative bacteria, few lactobacilli, and pH levels above 4.6, similar to the microbiota of patients with bacterial vaginosis. This study is aimed to investigate the change of the vaginal microbiota of rehsus...

  13. Relationship between lactobacilli and opportunistic bacterial pathogens associated with vaginitis

    OpenAIRE

    Razzak, Mohammad Sabri A.; Al-Charrakh, Alaa H.; AL-Greitty, Bara Hamid

    2011-01-01

    Background: Vaginitis, is an infectious inflammation of the vaginal mucosa, which sometimes involves the vulva. The balance of the vaginal flora is maintained by the Lactobacilli and its protective and probiotic role in treating and preventing vaginal infection by producing antagonizing compounds which are regarded as safe for humans. Aim: The aim of this study was to evaluate the protective role of Lactobacilli against common bacterial opportunistic pathogens in vaginitis and study the effec...

  14. Prevalence of vaginal candidiasis among pregnant women with abnormal vaginal discharge in Maiduguri.

    Science.gov (United States)

    Ibrahim, S M; Bukar, M; Mohammed, Y; Mohammed, B; Yahaya, M; Audu, B M; Ibrahim, H M; Ibrahim, H A

    2013-01-01

    Pregnancy represents a risk factor in the occurrence of vaginal candidiasis. To determine the prevalence and clinical features associated with abnormal vaginal discharge and C. albicans infection in pregnant women. High vaginal swab samples and data on epidemiological characteristics were collected from 400 pregnant women with complaints of abnormal vaginal discharge at booking clinic of University of Maiduguri Teaching Hospital. The data was analysed using SPSS 16.0 statistical software. The prevalence of abnormal vaginal discharge in pregnancy was 31.5%. The frequency of abnormal vaginal discharge was 183 (45.8%) among those aged 20-24 years, 291 (72.8%) in multipara, 223 (55.8%) in those with Primary education and 293 (73.2%) in unemployed. Vulval pruritus 300 (75.0%) was significantly related to abnormal vaginal discharge (P candidiasis were 151 (50.3%), 14 (56.0%) and 75 (75.0%) respectively (P vaginal discharge in pregnancy was high in this study and C. albicans was the commonest cause. It is recommended that a pregnant woman complaining of abnormal vaginal discharge be assessed and Laboratory diagnosis done in order to give appropriate treatment.

  15. Quantitative studies on the vaginal flora of asymptomatic women and patients with vaginitis and vaginosis.

    Science.gov (United States)

    Hammann, R; Kronibus, A; Lang, N; Werner, H

    1987-07-01

    Vaginal washings of 22 patients with vaginitis, 11 with vaginosis, and 12 healthy subjects were investigated quantitatively and qualitatively for aerobic and anaerobic bacteria and yeasts. Gardnerella vaginalis was recovered from 9 of the vaginitis patients, 7 of the vaginosis patients, and 4 of the asymptomatic subjects. Obligate anaerobes were found in 11 of the vaginitis patients, 4 of the vaginosis patients, and none of the control subjects. Bacteroides bivius was the anaerobe most frequently isolated from symptomatic subjects. Anaerobic vibrios were recovered twice from symptomatic subjects. The counts for Gardnerella vaginalis and anaerobes when present were generally very high. The most frequent aerobes were beta-hemolytic streptococci (group B) and staphylococci.

  16. Robust diamond meshes with unique wettability properties.

    Science.gov (United States)

    Yang, Yizhou; Li, Hongdong; Cheng, Shaoheng; Zou, Guangtian; Wang, Chuanxi; Lin, Quan

    2014-03-18

    Robust diamond meshes with excellent superhydrophobic and superoleophilic properties have been fabricated. Superhydrophobicity is observed for water with varying pH from 1 to 14 with good recyclability. Reversible superhydrophobicity and hydrophilicity can be easily controlled. The diamond meshes show highly efficient water-oil separation and water pH droplet transference.

  17. Mesh-graft urethroplasty: a case report

    OpenAIRE

    田中, 敏博; 滝川, 浩; 香川, 征; 長江, 浩朗

    1987-01-01

    We used a meshed free-foreskin transplant in a two-stage procedure for reconstruction of the extended stricture of urethra after direct vision urethrotomy. The results were excellent. Mesh-graft urethroplasty is a useful method for patients with extended strictures of the urethra or recurrent strictures after several operations.

  18. 7th International Meshing Roundtable '98

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, T.J.

    1998-10-01

    The goal of the 7th International Meshing Roundtable is to bring together researchers and developers from industry, academia, and government labs in a stimulating, open environment for the exchange of technical information related to the meshing process. In the past, the Roundtable has enjoyed significant participation from each of these groups from a wide variety of countries.

  19. Converting skeletal structures to quad dominant meshes

    DEFF Research Database (Denmark)

    Bærentzen, Jakob Andreas; Misztal, Marek Krzysztof; Welnicka, Katarzyna

    2012-01-01

    We propose the Skeleton to Quad-dominant polygonal Mesh algorithm (SQM), which converts skeletal structures to meshes composed entirely of polar and annular regions. Both types of regions have a regular structure where all faces are quads except for a single ring of triangles at the center of each...

  20. Adaptive mesh refinement in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Colella, Phillip; Wen, Tong

    2005-01-21

    In this paper, we evaluate Titanium's usability as a high-level parallel programming language through a case study, where we implement a subset of Chombo's functionality in Titanium. Chombo is a software package applying the Adaptive Mesh Refinement methodology to numerical Partial Differential Equations at the production level. In Chombo, the library approach is used to parallel programming (C++ and Fortran, with MPI), whereas Titanium is a Java dialect designed for high-performance scientific computing. The performance of our implementation is studied and compared with that of Chombo in solving Poisson's equation based on two grid configurations from a real application. Also provided are the counts of lines of code from both sides.

  1. Evaluation of vaginal flora and susceptibility test of microorganisms in reproductive-age women with or without vaginitis in primary care settings

    OpenAIRE

    Alim, Ahmet; Çetin, Ali; Yıldız, Çağlar

    2009-01-01

    AbstractAims. The treatment modalities of patients with vaginal discharge are generally related to their symptoms. The aim of this study was to evaluate vaginal flora and antibiogram analysis in reproductive-age women with or without vaginitis in primary care settings. Methods. Vaginal swabs were taken from 311 women who have vaginitis, and tested for the causative agents of vaginal discharge. The control group was 89 healthy women without vaginal discharge. Vaginal swaps were used in a comme...

  2. Erosion in extruder flow

    Science.gov (United States)

    Kaufman, Miron; Fodor, Petru S.

    A detailed analysis of the fluid flow in Tadmor's unwound channel model of the single screw extruder is performed by combining numerical and analytical methods. Using the analytical solution for the longitudinal velocity field (in the limit of zero Reynolds number) allows us to devote all the computational resources solely for a detailed numerical solution of the transversal velocity field. This high resolution 3D model of the fluid flow in a single-screw extruder allows us to identify the position and extent of Moffatt eddies that impede mixing. We further consider the erosion of particles (e.g. carbon-black agglomerates) advected by the polymeric flow. We assume a particle to be made of primary fragments bound together. In the erosion process a primary fragment breaks out of a given particle. Particles are advected by the laminar flow and they disperse because of the shear stresses imparted by the fluid. The time evolution of the numbers of particles of different sizes is described by the Bateman coupled differential equations used to model radioactivity. Using the particle size distribution we compute an entropic fragmentation index which varies from 0 for a monodisperse system to 1 for an extreme poly-disperse system.

  3. Optical clearing of vaginal tissues in cadavers

    Science.gov (United States)

    Chang, Chun-Hung; Hardy, Luke A.; Peters, Michael G.; Bastawros, Dina A.; Myers, Erinn M.; Kennelly, Michael J.; Fried, Nathaniel M.

    2018-02-01

    A nonsurgical laser procedure is being developed for treatment of female stress urinary incontinence (SUI). Previous studies in porcine vaginal tissues, ex vivo, as well as computer simulations, showed the feasibility of using near-infrared laser energy delivered through a transvaginal contact cooling probe to thermally remodel endopelvic fascia, while preserving the vaginal wall from thermal damage. This study explores optical properties of vaginal tissue in cadavers as an intermediate step towards future pre-clinical and clinical studies. Optical clearing of tissue using glycerol resulted in a 15-17% increase in optical transmission after 11 min at room temperature (and a calculated 32.5% increase at body temperature). Subsurface thermal lesions were created using power of 4.6 - 6.4 W, 5.2-mm spot, and 30 s irradiation time, resulting in partial preservation of vaginal wall to 0.8 - 1.1 mm depth.

  4. Vaginal itching and discharge - Adult and adolescent

    Science.gov (United States)

    ... 003158.htm Vaginal itching and discharge - adult and adolescent To use the sharing features on this page, ... fabric softeners, feminine sprays, ointments, creams, douches, and contraceptive foams or jellies or creams. This may irritate ...

  5. Vaginal neurofibroma in a hysterectomized poodle dog.

    Science.gov (United States)

    Sontas, B H; Altun, E D; Güvenc, K; Arun, S S; Ekici, H

    2010-12-01

    A 15-year-old, spayed, female poodle dog was presented for evaluation of a mass of tissue prolapsed from the vulva. The dog had been hysterectomized when it was 5 years old. A vaginal mass had been removed approximately 10 months before presentation. Haematological and serum biochemistry analyses demonstrated mild leucocytosis and glycaemia. A vaginal smear was predominantly made up of parabasal cells and intermediate cells with no neoplastic cells. Thoracal and abdominal radiographic findings were unremarkable. The ovaries could not be identified using abdominal ultrasonography. A midline exploratory laparotomy identified both ovaries that were surgically excised. The vaginal mass was also removed following an episiotomy procedure. Histopathological examination of the mass demonstrated that it was a neurofibroma. Both ovaries had cystic changes. Four months after the surgery, the owner reported that the dog was clinically normal. To the authors’ knowledge, this is the first reported case of a vaginal neurofibroma after an incomplete ovariohysterectomy in the dog.

  6. How Do Health Care Providers Diagnose Vaginitis?

    Science.gov (United States)

    ... used to diagnose vaginitis. 1 Centers for Disease Control and Prevention. (2010). Self-study STD ... Halvorson New Chief of Gynecologic Health and Disease Branch Division of Epidemiology, Statistics, ...

  7. What Are the Symptoms of Vaginitis?

    Science.gov (United States)

    ... Many women have no symptoms. Centers for Disease Control and Prevention. (2010). Self-study STD module—vaginitis . Retrieved ... New Chief of Gynecologic Health and Disease Branch Division of Epidemiology, Statistics, ...

  8. Short convalescence after vaginal prolapse surgery

    DEFF Research Database (Denmark)

    Ottesen, Marianne; Sørensen, Mette; Kehlet, Henrik

    2003-01-01

    OBJECTIVE: Retrospectively to describe the recommended convalescence according to patients who had undergone vaginal prolapse surgery in 1996-98, and prospectively to describe the need for and limiting factors for convalescence after vaginal prolapse surgery in 1999-2000 at a Danish University...... Hospital. METHODS: The retrospective study included a validated, postal, questionnaire and review of patient files. In the prospective study, we followed consecutive women after vaginal surgery in a fast-track setting using a multimodal rehabilitation model with well-defined recommendations...... exceeding 10 kg. Limiting factors were fatigue and pain. The 1-year subjective recurrence rate was 17%. CONCLUSION: Traditionally, recommended convalescence has been median 6 weeks after vaginal prolapse surgery. Convalescence has been shortened to 1-3 weeks with a multimodal rehabilitation model...

  9. Automatic mesh generation with QMESH program

    International Nuclear Information System (INIS)

    Ise, Takeharu; Tsutsui, Tsuneo

    1977-05-01

    Usage of the two-dimensional self-organizing mesh generation program, QMESH, is presented together with the descriptions and the experience, as it has recently been converted and reconstructed from the NEACPL version to the FACOM. The program package consists of the QMESH code to generate quadrilaterial meshes with smoothing techniques, the QPLOT code to plot the data obtained from the QMESH on the graphic COM, and the RENUM code to renumber the meshes by using a bandwidth minimization procedure. The technique of mesh reconstructuring coupled with smoothing techniques is especially useful when one generates the meshes for computer codes based on the finite element method. Several typical examples are given for easy access to the QMESH program, which is registered in the R.B-disks of JAERI for users. (auth.)

  10. ROLE OF MESH REPAIR IN PELVIC ORGAN PROLAPSE, WITH PARTICULAR REFERENCE TO VAULT PROLAPSE & NULLIPAROUS PROLAPSE

    Directory of Open Access Journals (Sweden)

    Geeta Vandana Reddi

    2017-12-01

    Full Text Available BACKGROUND Pelvic organ prolapse is a common complaint in gynaecological practice. Nulliparous prolapse is seen in 2% of female population and vault prolapse in 0.5% following hysterectomy. Various surgical procedures have been described for the repair of vault prolapse e.g. transvaginal sacrospinous colpopexy, transabdominal sacral colpopexy, Le Forte's operation, colpoclesis, posterior intravaginal sling plasty etc. The introduction of synthetic mesh like Prolene, Mersilene for the repair of vault prolapse have the advantage of tensile strength. In nulliparous prolapse and uterovaginal prolapse also, the supports of uterus are weakened, so there seems to be a definite advantage of mesh repair over sling surgeries. MATERIALS AND METHODS A prospective study done in 50 patients with vault prolapse, Nulliparous prolapse and patients with UV prolapse who want to retain their menstrual and reproductive function were identified and repair of defects were done. 2 cases who underwent both hysterectomy and sacral colpopexy in two sittings were included in the study. They were followed up for a period of 6 weeks - 29 months. RESULTS In the present study, the mean age for vault prolapse was 52.14 years, mean parity was 3.36. Vault prolapses were found to be more common after abdominal hysterectomy 60.97% compared to vaginal 39.02%. Common indication for hysterectomy is pelvic organ prolapse followed by DUB in this study. The mean time between the hysterectomy and vault prolapse in this study was 5.46 years. Importance should be given to proper enterocoele repair and vault suspense time of primary surgery. In this study incidence of smoking in vault prolapse cases was 34.14% significant. In cases of sacral colpopexy for vault prolapse in this study there were no major mesh related complications and the cure rate was 97.5%. So, sacral colpopexy with prolene mesh i.e. abdominal mesh repair can be employed as the primary surgery for vault prolapse. The safety

  11. Vaginal microbiota and viral sexually transmitted diseases.

    Science.gov (United States)

    Nardis, C; Mosca, L; Mastromarino, P

    2013-01-01

    Healthy vaginal microbiota is an important biological barrier to pathogenic microorganisms. When this predominantly Lactobacillus community is disrupted, decreased in abundance and replaced by different anaerobes, bacterial vaginosis (BV) may occur. BV is associated with prevalence and incidence of several sexually transmitted infections. This review provides background on BV, discusses the epidemiologic data to support a role of altered vaginal microbiota for acquisition of sexually transmitted diseases and analyzes mechanisms by which lactobacilli could counteract sexually transmitted viral infections.

  12. Fog water collection effectiveness: Mesh intercomparisons

    Science.gov (United States)

    Fernandez, Daniel; Torregrosa, Alicia; Weiss-Penzias, Peter; Zhang, Bong June; Sorensen, Deckard; Cohen, Robert; McKinley, Gareth; Kleingartner, Justin; Oliphant, Andrew; Bowman, Matthew

    2018-01-01

    To explore fog water harvesting potential in California, we conducted long-term measurements involving three types of mesh using standard fog collectors (SFC). Volumetric fog water measurements from SFCs and wind data were collected and recorded in 15-minute intervals over three summertime fog seasons (2014–2016) at four California sites. SFCs were deployed with: standard 1.00 m2 double-layer 35% shade coefficient Raschel; stainless steel mesh coated with the MIT-14 hydrophobic formulation; and FogHa-Tin, a German manufactured, 3-dimensional spacer fabric deployed in two orientations. Analysis of 3419 volumetric samples from all sites showed strong relationships between mesh efficiency and wind speed. Raschel mesh collected 160% more fog water than FogHa-Tin at wind speeds less than 1 m s–1 and 45% less for wind speeds greater than 5 m s–1. MIT-14 coated stainless-steel mesh collected more fog water than Raschel mesh at all wind speeds. At low wind speeds of steel mesh collected 3% more and at wind speeds of 4–5 m s–1, it collected 41% more. FogHa-Tin collected 5% more fog water when the warp of the weave was oriented vertically, per manufacturer specification, than when the warp of the weave was oriented horizontally. Time series measurements of three distinct mesh across similar wind regimes revealed inconsistent lags in fog water collection and inconsistent performance. Since such differences occurred under similar wind-speed regimes, we conclude that other factors play important roles in mesh performance, including in-situ fog event and aerosol dynamics that affect droplet-size spectra and droplet-to-mesh surface interactions.

  13. Rill erosion rates in burned forests

    Science.gov (United States)

    Joseph W. Wagenbrenner; Peter R. Robichaud

    2011-01-01

    Introduction Wildfires often produce large increases in runoff and erosion rates (e.g., Moody and Martin, 2009), and land managers need to predict the frequency and magnitude of postfire erosion to determine the needs for hazard response and possible erosion mitigation to reduce the impacts of increased erosion on public safety and valued resources. The Water Erosion...

  14. The vaginal microbiome: rethinking health and diseases

    Science.gov (United States)

    Ma, Bing; Forney, Larry J.; Ravel, Jacques

    2013-01-01

    Vaginal microbiota form a mutually beneficial relationship with their host and have major impact on health and disease. In recent years our understanding of vaginal bacterial community composition and structure has significantly broadened as a result of investigators using cultivation-independent methods based on the analysis of 16S ribosomal RNA (rRNA) gene sequences. In asymptomatic, otherwise healthy women, several kinds of vaginal microbiota exist, the majority often dominated by species of Lactobacillus, while others comprise a diverse array of anaerobic microorganisms. Bacterial vaginosis is the most common vaginal conditions and is vaguely characterized as the disruption of the equilibrium of the ‘normal’ vaginal microbiots. A better understanding of ‘normal’ and ‘healthy’ vaginal ecosystems that is based on its ‘true’ function and not simply on its composition would help better define health and further improve disease diagnostics as well as the development of more personalized regimens to promote health and treat diseases. PMID:22746335

  15. Vaginal microbial flora and outcome of pregnancy.

    Science.gov (United States)

    Donati, Laura; Di Vico, Augusto; Nucci, Marta; Quagliozzi, Lorena; Spagnuolo, Terryann; Labianca, Antonietta; Bracaglia, Marina; Ianniello, Francesca; Caruso, Alessandro; Paradisi, Giancarlo

    2010-04-01

    The vaginal microflora of a healthy asymptomatic woman consists of a wide variety of anaerobic and aerobic bacterial genera and species dominated by the facultative, microaerophilic, anaerobic genus Lactobacillus. The activity of Lactobacillus is essential to protect women from genital infections and to maintain the natural healthy balance of the vaginal flora. Increasing evidence associates abnormalities in vaginal flora during pregnancy with preterm labor and delivery with potential neonatal sequelae due to prematurity and poor perinatal outcome. Although this phenomenon is relatively common, even in populations of women at low risk for adverse events, the pathogenetic mechanism that leads to complications in pregnancy is still poorly understood. This review summarizes the current knowledge and uncertainties in defining alterations of vaginal flora in non-pregnant adult women and during pregnancy, and, in particular, investigates the issue of bacterial vaginosis and aerobic vaginitis. This could help specialists to identify women amenable to treatment during pregnancy leading to the possibility to reduce the preterm birth rate, preterm premature rupture of membranes, chorioamnionitis, neonatal, puerperal and maternal-fetal infectious diseases. Vaginal ecosystem study with the detection of pathogens is a key instrument in the prevention of preterm delivery, pPROM, chorioamnionitis, neonatal, puerperal and maternal-fetal infections.

  16. Successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia: A rare case report.

    Science.gov (United States)

    Liu, Yu; Wang, Yi-Feng

    2017-07-01

    We report a case of successful vaginal delivery after vaginal reconstruction with labium minus flaps in a 23-year-old patient with congenital vaginal atresia. The patient primarily presented with amenorrhea and cyclic abdominal pain; transabdominal ultrasonography revealed an enlarged uterus due to hematometra and absence of the lower segment of the vagina. Eight years ago, she had undergone an unsuccessful attempt at canalization at a local hospital. Upon referral to our hospital, she underwent vaginal reconstruction with labium minus flaps. Four months after this procedure, she became pregnant and, subsequently, successfully and safely vaginally delivered a healthy female baby weighing 3250 g at 38 +1 weeks' gestation. The delivery did not involve perineal laceration by lateral episiotomy. To the best of our knowledge, this is the first reported case of successful vaginal delivery at term after vaginal reconstruction with labium minus flaps in a patient with vaginal atresia. © 2017 Japan Society of Obstetrics and Gynecology.

  17. The comparison of hyaluronic acid vaginal tablets with estradiol vaginal tablets in the treatment of atrophic vaginitis: a randomized controlled trial.

    Science.gov (United States)

    Ekin, Murat; Yaşar, Levent; Savan, Kadir; Temur, Muzaffer; Uhri, Mehmet; Gencer, Işıl; Kıvanç, Esra

    2011-03-01

    To compare the effectiveness of the vaginal tablets of hyaluronic acid and estrodiol for the treatment of atrophic vaginitis. Forty-two postmenopausal women with symptoms of atrophic vaginitis were randomized to take vaginal tablets of 25 μg estradiol (n = 21) (group I) or 5 mg hyaluronic acid sodium salt (n = 21) (group II) for 8 weeks. The symptoms of atrophic vaginitis were evaluated by a self-assessed 4-point scale of composite score and the degree of epithelial atrophy was determined as, none, mild, moderate and severe. Vaginal pH and maturation index were measured and compared in both the groups. The symptoms were relieved significantly in both the groups (P Hyaluronic acid vaginal tablets can be used in patients with atrophic vaginitis who do not want to or can not take local estrogen treatment.

  18. The erosive potential of lollipops

    NARCIS (Netherlands)

    Brand, H.S.; Gambon, D.L.; Paap, A.; Bulthuis, M.S.; Veerman, E.C.I.; Nieuw Amerongen, A.V.

    2009-01-01

    Aim: To determine the erosive potential of several commercially available lollipops and the protective effect of saliva. Methods: The erosive potential of lollipops was determined in vitro by measuring the pH and neutralisable acidity. Subsequently, 10 healthy volunteers tested different types of

  19. Wind erosion processes and control

    Science.gov (United States)

    Wind erosion continues to threaten the sustainability of our nations' soil, air, and water resources. To effectively apply conservation systems to prevent wind driven soil loss, an understanding of the fundamental processes of wind erosion is necessary so that land managers can better recognize the ...

  20. Nonspecific aerobic vaginitis and pregnancy.

    Science.gov (United States)

    Curzik, D; Drazancić, A; Hrgović, Z

    2001-01-01

    During the period 1996-1998, cervical swabs of 50 pregnant women with subacute amniotic infection syndrome (AIS) and the semen of their consorts were bacteriologically analyzed. In the control group were 50 healthy pregnant women and their consorts too. Pathogenic bacteria (the most common were Escherichia coli, Staphylococcus haemolyticus, Chlamydia trachomatis and Ureaplasma urealyticum) were isolated from the cervical swab of 50 pregnant patients with AIS in 86.0% of them, while in the control group of healthy pregnant women in 28.0%. Pathogenic bacteria were present in 70.0% of semen of consorts pregnant women with AIS and only in 30.0% of semen of the control group. The congruity of pathogenic bacteria in the cervical swab and semen in the investigated group was 69.2%, while only 35.7% in the control group. Following erythromycin, cefuroxime and local tetracyclin treatment, the negativization of the cervical swab resulted in 30 pregnant patients with AIS, while the colonization persisted in 20 of them. The outcome of pregnancy was significantly better in cases with negativization of the cervical swab: perinatal loss was 6.7%, while in cases with persistent infection it was 55.0%. The authors presume the amniotic infection syndrome should be ascending manifestation of nonspecific vaginitis, which is maintained by the consort's urogenital infection. AIS should be classified as a 'sexually-transmitted disease'. Copyright 2001 S. Karger AG, Basel

  1. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis.

    Science.gov (United States)

    Brody, Stuart; Weiss, Petr

    2010-08-01

    Evidence was recently provided for vaginal orgasm, orgasm triggered purely by penile-vaginal intercourse (PVI), being associated with better psychological functioning. Common sex education and sexual medicine approaches might undermine vaginal orgasm benefits. To examine the extent to which women's vaginal orgasm consistency is associated with (i) being told in childhood or adolescence that the vagina was the important zone for inducing female orgasm; (ii) how well they focus mentally on vaginal sensations during PVI; (iii) greater PVI duration; and (iv) preference for above-average penis length.   In a representative sample of the Czech population, 1,000 women reported their vaginal orgasm consistency (from never to almost every time; only 21.9% never had a vaginal orgasm), estimates of their typical foreplay and PVI durations, what they were told in childhood and adolescence was the important zone for inducing female orgasm, their degree of focus on vaginal sensations during PVI, and whether they were more likely to orgasm with a longer than average penis. The association of vaginal orgasm consistency with the predictors noted above. Vaginal orgasm consistency was associated with all hypothesized correlates. Multivariate analysis indicated the most important predictors were being educated that the vagina is important for female orgasm, being mentally focused on vaginal sensations during PVI, and in some analyses duration of PVI (but not foreplay) and preferring a longer than average penis. Focusing attention on penile-vaginal sensation supports vaginal orgasm and the myriad benefits thereof. Brody S, and Weiss P. Vaginal orgasm is associated with vaginal (not clitoral) sex education, focusing mental attention on vaginal sensations, intercourse duration, and a preference for a longer penis. © 2009 International Society for Sexual Medicine.

  2. Erosion--corrosion

    International Nuclear Information System (INIS)

    Vyas, B.

    1978-01-01

    The deterioration of materials by corrosion or erosion by itself presents a formidable problem and for this reason investigators have studied these two phenomena independently. In fact, there are very few systematic studies on E-C and the majority of references mention it only in passing. In most real systems, however, the two destructive processes take place simultaneously, hence the purpose of this review is to present the various interactions between the chemical and mechanical agents leading to accelerated degradation of the material. The papers cited in the review are those that lead to a better understanding of the process involved in the accelerated rate of material loss under E-C conditions

  3. [CLINICAL EVALUATION OF THE NEW ANTISEPTIC MESHES].

    Science.gov (United States)

    Gogoladze, M; Kiladze, M; Chkhikvadze, T; Jiqia, D

    2016-12-01

    Improving the results of hernia treatment and prevention of complications became a goal of our research which included two parts - experimental and clinical. Histomorphological and bacteriological researches showed that the best result out of the 3 control groups was received in case of covering implant "Coladerm"+ with chlorhexidine. Based on the experiment results working process continued in clinics in order to test and introduce new "coladerm"+ chlorhexidine covered poliprophilene meshes into practice. For clinical illustration there were 60 patients introduced to the research who had hernioplasty procedures by different nets: I group - standard meshes+"coladerm"+chlorhexidine, 35 patients; II group - standard meshes +"coladerm", 15 patients; III group - standard meshes, 10 patients. Assessment of the wound and echo-control was done post-surgery on the 8th, 30th and 90th days. This clinical research based on the experimental results once again showed the best anti-microbe features of new antiseptic polymeric biocomposite meshes (standard meshes+"coladerm"+chlorhexidine); timely termination of regeneration and reparation processes without any post-surgery suppurative complications. We hope that new antiseptic polymeric biocomposite meshes presented by us will be successfully used in surgical practice of hernia treatment based on and supported by expermental-clinical research.

  4. Vaginal estrogen: a dual-edged sword in postoperative healing of the vaginal wall.

    Science.gov (United States)

    Ripperda, Christopher M; Maldonado, Pedro Antonio; Acevedo, Jesus F; Keller, Patrick W; Akgul, Yucel; Shelton, John M; Word, Ruth Ann

    2017-07-01

    Reconstructive surgery for pelvic organ prolapse is plagued with high failure rates possibly due to impaired healing or regeneration of the vaginal wall. Here, we tested the hypothesis that postoperative administration of local estrogen, direct injection of mesenchymal stem cells (MSCs), or both lead to improved wound healing of the injured vagina in a menopausal rat model. Ovariectomized rats underwent surgical injury to the posterior vaginal wall and were randomized to treatment with placebo (n = 41), estrogen cream (n = 47), direct injection of MSCs (n = 39), or both (n = 43). MSCs did not survive after injection and had no appreciable effects on healing of the vaginal wall. Acute postoperative administration of vaginal estrogen altered the response of the vaginal wall to injury with decreased stiffness, decreased collagen content, and decreased expression of transcripts for matrix components in the stromal compartment. Conversely, vaginal estrogen resulted in marked proliferation of the epithelial layer and increased expression of genes related to epithelial barrier function and protease inhibition. Transcripts for genes involved in chronic inflammation and adaptive immunity were also down-regulated in the estrogenized epithelium. Collectively, these data indicate that, in contrast to the reported positive effects of preoperative estrogen on the uninjured vagina, acute administration of postoperative vaginal estrogen has adverse effects on the early phase of healing of the stromal layer. In contrast, postoperative estrogen plays a positive role in healing of the vaginal epithelium after injury.

  5. Patterns of Expression of Vaginal T-Cell Activation Markers during Estrogen-Maintained Vaginal Candidiasis

    Directory of Open Access Journals (Sweden)

    Al-Sadeq Ameera

    2008-12-01

    Full Text Available The immunosuppressive activity of estrogen was further investigated by assessing the pattern of expression of CD25, CD28, CD69, and CD152 on vaginal T cells during estrogen-maintained vaginal candidiasis. A precipitous and significant decrease in vaginal fungal burden toward the end of week 3 postinfection was concurrent with a significant increase in vaginal lymphocyte numbers. During this period, the percentage of CD3+, CD3+CD4+, CD152+, and CD28+ vaginal T cells gradually and significantly increased. The percentage of CD3+ and CD3+CD4+ cells increased from 43% and 15% at day 0 to 77% and 40% at day 28 postinfection. Compared with 29% CD152+ vaginal T cells in naive mice, > 70% of vaginal T cells were CD152+ at day 28 postinfection. In conclusion, estrogen-maintained vaginal candidiasis results in postinfection time-dependent changes in the pattern of expression of CD152, CD28, and other T-cell markers, suggesting that T cells are subject to mixed suppression and activation signals.

  6. Focal depth measurements of the vaginal wall: a new method to noninvasively quantify vaginal wall thickness in the diagnosis and treatment of vaginal atrophy

    NARCIS (Netherlands)

    Weber, Maaike A.; Diedrich, Chantal M.; Ince, Can; Roovers, Jan-Paul

    2016-01-01

    The aim of the study was to evaluate if vaginal focal depth measurement could be a noninvasive method to quantify vaginal wall thickness. Postmenopausal women undergoing topical estrogen therapy because of vaginal atrophy (VA) were recruited. VA was diagnosed based on the presence of symptoms and

  7. Fog water collection effectiveness: Mesh intercomparisons

    Science.gov (United States)

    Fernandez, Daniel; Torregrosa, Alicia; Weiss-Penzias, Peter; Zhang, Bong June; Sorensen, Deckard; Cohen, Robert; McKinley, Gareth; Kleingartner, Justin; Oliphant, Andrew; Bowman, Matthew

    2018-01-01

    To explore fog water harvesting potential in California, we conducted long-term measurements involving three types of mesh using standard fog collectors (SFC). Volumetric fog water measurements from SFCs and wind data were collected and recorded in 15-minute intervals over three summertime fog seasons (2014–2016) at four California sites. SFCs were deployed with: standard 1.00 m2 double-layer 35% shade coefficient Raschel; stainless steel mesh coated with the MIT-14 hydrophobic formulation; and FogHa-Tin, a German manufactured, 3-dimensional spacer fabric deployed in two orientations. Analysis of 3419 volumetric samples from all sites showed strong relationships between mesh efficiency and wind speed. Raschel mesh collected 160% more fog water than FogHa-Tin at wind speeds less than 1 m s–1 and 45% less for wind speeds greater than 5 m s–1. MIT-14 coated stainless-steel mesh collected more fog water than Raschel mesh at all wind speeds. At low wind speeds of wind speeds of 4–5 m s–1, it collected 41% more. FogHa-Tin collected 5% more fog water when the warp of the weave was oriented vertically, per manufacturer specification, than when the warp of the weave was oriented horizontally. Time series measurements of three distinct mesh across similar wind regimes revealed inconsistent lags in fog water collection and inconsistent performance. Since such differences occurred under similar wind-speed regimes, we conclude that other factors play important roles in mesh performance, including in-situ fog event and aerosol dynamics that affect droplet-size spectra and droplet-to-mesh surface interactions.

  8. Mesh optimization for microbial fuel cell cathodes constructed around stainless steel mesh current collectors

    KAUST Repository

    Zhang, Fang

    2011-02-01

    Mesh current collectors made of stainless steel (SS) can be integrated into microbial fuel cell (MFC) cathodes constructed of a reactive carbon black and Pt catalyst mixture and a poly(dimethylsiloxane) (PDMS) diffusion layer. It is shown here that the mesh properties of these cathodes can significantly affect performance. Cathodes made from the coarsest mesh (30-mesh) achieved the highest maximum power of 1616 ± 25 mW m-2 (normalized to cathode projected surface area; 47.1 ± 0.7 W m-3 based on liquid volume), while the finest mesh (120-mesh) had the lowest power density (599 ± 57 mW m-2). Electrochemical impedance spectroscopy showed that charge transfer and diffusion resistances decreased with increasing mesh opening size. In MFC tests, the cathode performance was primarily limited by reaction kinetics, and not mass transfer. Oxygen permeability increased with mesh opening size, accounting for the decreased diffusion resistance. At higher current densities, diffusion became a limiting factor, especially for fine mesh with low oxygen transfer coefficients. These results demonstrate the critical nature of the mesh size used for constructing MFC cathodes. © 2010 Elsevier B.V. All rights reserved.

  9. Polygonal Prism Mesh in the Viscous Layers for the Polyhedral Mesh Generator, PolyGen

    International Nuclear Information System (INIS)

    Lee, Sang Yong; Park, Chan Eok; Kim, Shin Whan

    2015-01-01

    Polyhedral mesh has been known to have some benefits over the tetrahedral mesh. Efforts have been made to set up a polyhedral mesh generation system with open source programs SALOME and TetGen. The evaluation has shown that the polyhedral mesh generation system is promising. But it is necessary to extend the capability of the system to handle the viscous layers to be a generalized mesh generator. A brief review to the previous works on the mesh generation for the viscous layers will be made in section 2. Several challenging issues for the polygonal prism mesh generation will be discussed as well. The procedure to generate a polygonal prism mesh will be discussed in detail in section 3. Conclusion will be followed in section 4. A procedure to generate meshes in the viscous layers with PolyGen has been successfully designed. But more efforts have to be exercised to find the best way for the generating meshes for viscous layers. Using the extrusion direction of the STL data will the first of the trials in the near future

  10. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling

    Science.gov (United States)

    ITO, TAKUJI; BAI, TAO; TANAKA, TETSUJI; YOSHIDA, KENJI; UEYAMA, TAKASHI; MIYAJIMA, MASAYASU; NEGISHI, TAKAYUKI; KAWASAKI, TAKAHIKO; TAKAMATSU, HYOTA; KIKUTANI, HITOSHI; KUMANOGOH, ATSUSHI; YUKAWA, KAZUNORI

    2015-01-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild-type (WT) mice. Administration of β-estradiol to infant Sema4D-deficient (Sema4D−/−) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β-estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin-B1, was examined as well as the level of apoptosis in the vaginal epithelia of five-week-old WT and Sema4D−/− mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin-B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase-3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five-week-old Sema4D−/− mice compared with WT mice. The addition of recombinant Sema4D to Sema4D−/− vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis-inducing activity of Sema4D. The experimental reduction of

  11. Semaphorin 4D induces vaginal epithelial cell apoptosis to control mouse postnatal vaginal tissue remodeling.

    Science.gov (United States)

    Ito, Takuji; Bai, Tao; Tanaka, Tetsuji; Yoshida, Kenji; Ueyama, Takashi; Miyajima, Masayasu; Negishi, Takayuki; Kawasaki, Takahiko; Takamatsu, Hyota; Kikutani, Hitoshi; Kumanogoh, Atsushi; Yukawa, Kazunori

    2015-02-01

    The opening of the mouse vaginal cavity to the skin is a postnatal tissue remodeling process that occurs at approximately five weeks of age for the completion of female genital tract maturation at puberty. The tissue remodeling process is primarily composed of a hormonally triggered apoptotic process predominantly occurring in the epithelium of the distal section of the vaginal cavity. However, the detailed mechanism underlying the apoptotic induction remains to be elucidated. In the present study, it was observed that the majority of BALB/c mice lacking the class 4 semaphorin, semaphorin 4D (Sema4D), developed imperforate vagina and hydrometrocolpos resulting in a perpetually unopened vaginal cavity regardless of a normal estrogen level comparable with that in wild‑type (WT) mice. Administration of β‑estradiol to infant Sema4D‑deficient (Sema4D‑/‑) mice did not induce precocious vaginal opening, which was observed in WT mice subjected to the same β‑estradiol administration, excluding the possibility that the closed vaginal phenotype was due to insufficient estrogen secretion at the time of vaginal opening. In order to assess the role of Sema4D in the postnatal vaginal tissue remodeling process, the expression of Sema4D and its receptor, plexin‑B1, was examined as well as the level of apoptosis in the vaginal epithelia of five‑week‑old WT and Sema4D‑/‑ mice. Immunohistochemical analyses confirmed the localization of Sema4D and plexin‑B1 in the mouse vaginal epithelia. Terminal deoxynucleotidyl transferase dUTP nick end labeling assay and immunohistochemistry detecting activated caspase‑3 revealed significantly fewer apoptotic cells in situ in the vaginal mucosa of five‑week‑old Sema4D‑/‑ mice compared with WT mice. The addition of recombinant Sema4D to Sema4D‑/‑ vaginal epithelial cells in culture significantly enhanced apoptosis of the vaginal epithelial cells, demonstrating the apoptosis‑inducing activity of Sema4D. The

  12. Using REE tracers to measure sheet erosion changing to rill erosion

    International Nuclear Information System (INIS)

    Liu Puling; Xue Yazhou; Song Wei; Wang Mingyi; Ju Tongjun

    2004-01-01

    Rare Earth Elements (REE) tracer method was used to study sheet erosion changing to rill erosion on slope land. By placing different rare earth elements of different soil depth across a slope in an indoor plot, two simulated rainfalls were applied to study the change of erosion type and the rill erosion process. The results indicate that the main erosion type is sheet erosion at the beginning of the rainfalls, and serious erosion happens after rill erosion appears. Accumulated sheet and rill erosion amounts increase with the rainfalls time. The percentage of sheet erosion amount decreases and rill erosion percentage increases with time. At the end of the rainfalls, the total rill erosion amounts are 4-5 times more than sheet erosion. In this paper, a new REE tracer method was used to quantitatively distinguish sheet and rill erosion amounts. The new REE tracer method should be useful to future studying of erosion processes on slope lands. (authors)

  13. Is vaginal microscopy an essential tool for the management of women presenting with vaginal discharge?

    Science.gov (United States)

    Lascar, R M; Devakumar, H; Jungmann, E; Copas, A; Arthur, G; Mercey, D

    2008-12-01

    Point-of-care microscopy is the gold standard for the diagnosis of vaginal discharge in genitourinary (GU) medicine clinics but not used in primary care settings and reproductive health clinics to which many patients present. In our GU medicine clinic setting, we conducted an audit to assess the utility of microscopy of vaginal secretions versus clinical diagnosis alone for the differential diagnosis of uncomplicated lower vaginal infections. Clinical diagnosis (including pH) of bacterial vaginosis had a sensitivity between 85% and 88% at two clinic sites. Our results suggest that it may be safe and more cost-effective to restrict vaginal microscopy to a subgroup of women presenting with vaginal discharge.

  14. Mesh Optimization for Ground Vehicle Aerodynamics

    OpenAIRE

    Adrian Gaylard; Essam F Abo-Serie; Nor Elyana Ahmad

    2010-01-01

    Mesh optimization strategy for estimating accurate drag of a ground vehicle is proposed based on examining the effect of different mesh parameters.  The optimized mesh parameters were selected using design of experiment (DOE) method to be able to work in a...

  15. Engagement of Metal Debris into Gear Mesh

    Science.gov (United States)

    handschuh, Robert F.; Krantz, Timothy L.

    2010-01-01

    A series of bench-top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined.

  16. Mesh requirements for neutron transport calculations

    International Nuclear Information System (INIS)

    Askew, J.R.

    1967-07-01

    Fine-structure calculations are reported for a cylindrical natural uranium-graphite cell using different solution methods (discrete ordinate and collision probability codes) and varying the spatial mesh. It is suggested that of formulations assuming the source constant in a mesh interval the differential approach is generally to be preferred. Due to cancellation between approximations made in the derivation of the finite difference equations and the errors in neglecting source variation, the discrete ordinate code gave a more accurate estimate of fine structure for a given mesh even for unusually coarse representations. (author)

  17. Modeling soil erosion in a watershed

    OpenAIRE

    Lanuza, R.

    1999-01-01

    Most erosion models have been developed based on a plot scale and have limited application to a watershed due to the differences in aerial scale. In order to address this limitation, a GIS-assisted methodology for modeling soil erosion was developed using PCRaster to predict the rate of soil erosion at watershed level; identify the location of erosion prone areas; and analyze the impact of landuse changes on soil erosion. The general methodology of desktop modeling or soil erosion at watershe...

  18. Aerobic vaginal pathogens and their sensitivity pattern.

    Science.gov (United States)

    Mumtaz, Shamim; Ahmad, Mumtaz; Aftab, Irum; Akhtar, Naeem; ul Hassan, Masood; Hamid, Abdul

    2008-01-01

    The vaginal flora is a complicated environment, containing dozens of microbiological species in variable quantities and relative proportions. The frequent cause of vaginal discharge is an infection or colonization with different microorganisms. Some pathologic conditions causing vaginitis are well defined yet, 7-72% of women with vaginitis may remain undiagnosed and such forms of abnormal vaginal flora neither considered as normal, nor can be called bacterial vaginosis have been termed as 'intermediate flora' and its management probably differ from that of bacterial vaginosis. It is of crucial importance in pregnant females at risk of preterm delivery. The present study has been conducted especially to elucidate this type of aerobic vaginal isolates and their culture and sensitivity towards currently used antibiotics. This study was conducted at the Microbiology Department of Fauji Foundation Hospital, Rawalpindi over a period of two years (April 2004-March 2006). One thousand, nine hundred and twenty three high vaginal swabs, both from indoor and outdoor patients were collected, cultured and their susceptibility to various antibiotics was determined. Significant growth was obtained in 731 samples. The highest frequency of infection (39.5%) was observed at 31-40 years followed by 41-50 years (35.8%). About 76% were from outdoor and 24% were from indoor patients. Staphylococcus aureus was the most prevalent vaginal pathogen at 11-60 yrs & with highest prevalence at 31-40 years followed by 41-50 years. It was a predominant pathogen in both indoor (35%) as well as outdoor (41.6%) patients, followed by enteric gram-negative bacilli and other gram-positive cocci. There were very few antibiotics among the conventionally available aminoglycosides, third generation cephalosporins, penicillin, quinolones, sulfonamides and tetracyclines possessing good sensitivity (> 80%) against any one the common aerobic vaginal pathogens. The effective chemotherapeutics agents belong to

  19. Screening of mucoadhesive vaginal gel formulations

    Directory of Open Access Journals (Sweden)

    Ana Ochoa Andrade

    2014-12-01

    Full Text Available Rational design of vaginal drug delivery formulations requires special attention to vehicle properties that optimize vaginal coating and retention. The aim of the present work was to perform a screening of mucoadhesive vaginal gels formulated with carbomer or carrageenan in binary combination with a second polymer (carbomer, guar or xanthan gum. The gels were characterised using in vitroadhesion, spreadability and leakage potential studies, as well as rheological measurements (stress and frequency sweep tests and the effect of dilution with simulated vaginal fluid (SVF on spreadability. Results were analysed using analysis of variance and multiple factor analysis. The combination of polymers enhanced adhesion of both primary gelling agents, carbomer and carrageenan. From the rheological point of view all formulations presented a similar behaviour, prevalently elastic and characterised by loss tangent values well below 1. No correlation between rheological and adhesion behaviour was found. Carbomer and carrageenan gels containing the highest percentage of xanthan gum displayed good in vitro mucoadhesion and spreadability, minimal leakage potential and high resistance to dilution. The positive results obtained with carrageenan-xanthan gum-based gels can encourage the use of natural biocompatible adjuvants in the composition of vaginal products, a formulation field that is currently under the synthetic domain.

  20. The vaginal microbiota and susceptibility to HIV.

    Science.gov (United States)

    Buve, Anne; Jespers, Vicky; Crucitti, Tania; Fichorova, Raina N

    2014-10-23

    There is some evidence that the risk of HIV infection per heterosexual act is higher in low-income countries than in high-income countries. We hypothesize that variations in per sex-act transmission probability of HIV may in part be attributed to differences in the composition and function of the vaginal microbiota between different populations. This paper presents data that are in support of this hypothesis. Experimental and clinical studies have provided evidence that the normal vaginal microbiota plays a protective role against acquisition of HIV and other sexually transmitted infections. Epidemiological studies have convincingly shown that disturbances of the vaginal microbiome, namely intermediate flora and bacterial vaginosis, increase the risk of acquisition of HIV infection. A review of the literature found large differences in prevalence of bacterial vaginosis between different populations, with the highest prevalence rates found in black populations. Possible explanations for these differences are presented including data suggesting that there are ethnic differences in the composition of the normal vaginal microbiota. Lastly, interventions are discussed to restore and maintain a healthy vaginal environment. 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins

  1. Group B Streptococcus and the Vaginal Microbiota.

    Science.gov (United States)

    Rosen, Geoffrey H; Randis, Tara M; Desai, Purnahamsi V; Sapra, Katherine J; Ma, Bing; Gajer, Pawel; Humphrys, Michael S; Ravel, Jacques; Gelber, Shari E; Ratner, Adam J

    2017-09-15

    Streptococcus agalactiae (group B Streptococcus [GBS]) is an important neonatal pathogen and emerging cause of disease in adults. The major risk factor for neonatal disease is maternal vaginal colonization. However, little is known about the relationship between GBS and vaginal microbiota. Vaginal lavage samples from nonpregnant women were tested for GBS, and amplicon-based sequencing targeting the 16S ribosomal RNA V3-V4 region was performed. Four hundred twenty-eight of 432 samples met the high-quality read threshold. There was no relationship between GBS carriage and demographic characteristics, α-diversity, or overall vaginal microbiota community state type (CST). Within the non-Lactobacillus-dominant CST IV, GBS positive status was significantly more prevalent in CST IV-A than CST IV-B. Significant clustering by GBS status was noted on principal coordinates analysis, and 18 individual taxa were found to be significantly associated with GBS carriage by linear discriminant analysis. After adjusting for race/ethnicity, 4 taxa were positively associated with GBS, and 6 were negatively associated. Vaginal microbiota CST and α-diversity are not related to GBS status. However, specific microbial taxa are associated with colonization of this important human pathogen, highlighting a potential role for the microbiota in promotion or inhibition of GBS colonization. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  2. Diagnostic and therapeutic advancements for aerobic vaginitis.

    Science.gov (United States)

    Han, Cha; Wu, Wenjuan; Fan, Aiping; Wang, Yingmei; Zhang, Huiying; Chu, Zanjun; Wang, Chen; Xue, Fengxia

    2015-02-01

    Aerobic vaginitis (AV) is a newly defined clinical entity that is distinct from candidiasis, trichomoniasis and bacterial vaginosis (BV). Because of the poor recognition of AV, this condition can lead to treatment failures and is associated with severe complications, such as pelvic inflammatory disease, infertility, preterm birth and foetal infections. This review describes the diagnosis and treatment of AV and the relationship between AV and pregnancy. The characteristics of AV include severely depressed levels of lactobacilli, increased levels of aerobic bacteria and an inflamed vagina. The diagnosis is made by microscopy on wet mounts of fresh vaginal fluid, and some distinct clinical features are recognized. Vaginal suppositories that contain kanamycin or clindamycin have shown curative effects in nonpregnant women. Additionally, the application of topical probiotics can restore the vaginal flora and reduce the recurrence of AV. Clindamycin vaginal suppositories and probiotics may be a better choice for gravida with AV than metronidazole. AV requires prompt attention, and the early diagnosis and treatment of AV during pregnancy significantly improves perinatal outcomes. Further research is needed to define the pathogenesis, diagnostic criteria and standard treatment guidelines for AV.

  3. [Vaginitis and vaginosis. Comparison of two periods].

    Science.gov (United States)

    Ceruti, M; Canestrelli, M; Piantelli, G; Amone, F; Condemi, V; De Paolis, P; Ludovici, G; Somenzi, P

    1993-10-01

    Vaginitis is the most frequent gynecological disease. It is characterized by objective and subjective signs of inflammation and differs from bacterial vaginosis (BV) which is an abnormal condition of the vaginal ecosystem caused by the excessive growth of aerobic and anaerobic flora normally present in the vagina with an increased risk of pelvic inflammatory disease (PID). The authors report the results of a study carried out at the Centre for Gynecological Infections at the Clinic of Obstetrics and Gynecology of the University of Parma. 828 patients were enrolled in the study during the period 1985-86 and 1559 patients during the two-year period 1991-92. The aim of the study was to evaluate variations in epidemiological data for vaginitis and bacterial vaginosis in the two periods examined. No significant changes were observed (p > 0.05) with regard to the prevalence of Ca, Tv and BV forms. On the other hand, there was a significant reduction (p vaginitis and BV showed a reduction of other microorganisms and an increase in negative vaginal swabs in adults (> 20 years old).

  4. Gastric Mucosal Erosions - Radiologic evaluation -

    International Nuclear Information System (INIS)

    Kim, Seung Hyup

    1985-01-01

    70 cases of gastric mucosal erosions were diagnosed by double contrast upper gastrointestinal examinations and endoscopic findings. Analyzing the radiologic findings of these 70 cases of gastric mucosal erosions, the following results were obtained. 1. Among the total 70 cases, 65 cases were typical varioliform erosions showing central depressions and surrounding mucosal elevations. Remaining 5 cases were erosions of acute phase having multiple irregular depressions without surrounding elevations. 2. The gastric antrum was involved alone or in part in all cases. Duodenal bulb was involved with gastric antrum in 4 cases. 3. The majority of the cases had multiple erosions. There were only 2 cases of single erosion. 4. In 65 cases of varioliform erosions; 1) The diameter of the surrounding elevations varied from 3 to 20 mm with the majority (47 cases) between 6 and 10 mm. 2) In general, the surrounding elevations with sharp margin on double contrast films were also clearly demonstrated on compression films but those with faint margin were not. 3) The size of the central barium collections varied from pinpoint to 10 mm with the majority under 5 mm. The shape of the central barium collections in majority of the cases were round with a few cases of linear, triangular or star-shape. 5. In 5 cases of acute phase erosions; 1) All the 5 cases were females. 2) On double contrast radiography, all the cases showed multiple irregular depressed lesions without surrounding elevations. 3) 1 case had the history of hematemesis. 4) In 1 case, there was marked radiological improvement on follow-up study of 2 months interval. 6. In 23 cases, there were coexistent diseases with gastric mucosal erosions. These were 13 cases of duodenal bulb ulcers,7 cases of benign gastric ulcers and 3 others

  5. Obtuse triangle suppression in anisotropic meshes

    KAUST Repository

    Sun, Feng; Choi, Yi King; Wang, Wen Ping; Yan, Dongming; Liu, Yang; Lé vy, Bruno L.

    2011-01-01

    Anisotropic triangle meshes are used for efficient approximation of surfaces and flow data in finite element analysis, and in these applications it is desirable to have as few obtuse triangles as possible to reduce the discretization error. We present a variational approach to suppressing obtuse triangles in anisotropic meshes. Specifically, we introduce a hexagonal Minkowski metric, which is sensitive to triangle orientation, to give a new formulation of the centroidal Voronoi tessellation (CVT) method. Furthermore, we prove several relevant properties of the CVT method with the newly introduced metric. Experiments show that our algorithm produces anisotropic meshes with much fewer obtuse triangles than using existing methods while maintaining mesh anisotropy. © 2011 Elsevier B.V. All rights reserved.

  6. Connectivity editing for quad-dominant meshes

    KAUST Repository

    Peng, Chihan; Wonka, Peter

    2013-01-01

    and illustrate the advantages and disadvantages of different strategies for quad-dominant mesh design. © 2013 The Author(s) Computer Graphics Forum © 2013 The Eurographics Association and John Wiley & Sons Ltd.

  7. Grid adaptation using chimera composite overlapping meshes

    Science.gov (United States)

    Kao, Kai-Hsiung; Liou, Meng-Sing; Chow, Chuen-Yen

    1994-01-01

    The objective of this paper is to perform grid adaptation using composite overlapping meshes in regions of large gradient to accurately capture the salient features during computation. The chimera grid scheme, a multiple overset mesh technique, is used in combination with a Navier-Stokes solver. The numerical solution is first converged to a steady state based on an initial coarse mesh. Solution-adaptive enhancement is then performed by using a secondary fine grid system which oversets on top of the base grid in the high-gradient region, but without requiring the mesh boundaries to join in any special way. Communications through boundary interfaces between those separated grids are carried out using trilinear interpolation. Application to the Euler equations for shock reflections and to shock wave/boundary layer interaction problem are tested. With the present method, the salient features are well-resolved.

  8. Grid adaption using Chimera composite overlapping meshes

    Science.gov (United States)

    Kao, Kai-Hsiung; Liou, Meng-Sing; Chow, Chuen-Yen

    1993-01-01

    The objective of this paper is to perform grid adaptation using composite over-lapping meshes in regions of large gradient to capture the salient features accurately during computation. The Chimera grid scheme, a multiple overset mesh technique, is used in combination with a Navier-Stokes solver. The numerical solution is first converged to a steady state based on an initial coarse mesh. Solution-adaptive enhancement is then performed by using a secondary fine grid system which oversets on top of the base grid in the high-gradient region, but without requiring the mesh boundaries to join in any special way. Communications through boundary interfaces between those separated grids are carried out using tri-linear interpolation. Applications to the Euler equations for shock reflections and to a shock wave/boundary layer interaction problem are tested. With the present method, the salient features are well resolved.

  9. Shape space exploration of constrained meshes

    KAUST Repository

    Yang, Yongliang

    2011-12-12

    We present a general computational framework to locally characterize any shape space of meshes implicitly prescribed by a collection of non-linear constraints. We computationally access such manifolds, typically of high dimension and co-dimension, through first and second order approximants, namely tangent spaces and quadratically parameterized osculant surfaces. Exploration and navigation of desirable subspaces of the shape space with regard to application specific quality measures are enabled using approximants that are intrinsic to the underlying manifold and directly computable in the parameter space of the osculant surface. We demonstrate our framework on shape spaces of planar quad (PQ) meshes, where each mesh face is constrained to be (nearly) planar, and circular meshes, where each face has a circumcircle. We evaluate our framework for navigation and design exploration on a variety of inputs, while keeping context specific properties such as fairness, proximity to a reference surface, etc. © 2011 ACM.

  10. Shape space exploration of constrained meshes

    KAUST Repository

    Yang, Yongliang; Yang, Yijun; Pottmann, Helmut; Mitra, Niloy J.

    2011-01-01

    We present a general computational framework to locally characterize any shape space of meshes implicitly prescribed by a collection of non-linear constraints. We computationally access such manifolds, typically of high dimension and co-dimension, through first and second order approximants, namely tangent spaces and quadratically parameterized osculant surfaces. Exploration and navigation of desirable subspaces of the shape space with regard to application specific quality measures are enabled using approximants that are intrinsic to the underlying manifold and directly computable in the parameter space of the osculant surface. We demonstrate our framework on shape spaces of planar quad (PQ) meshes, where each mesh face is constrained to be (nearly) planar, and circular meshes, where each face has a circumcircle. We evaluate our framework for navigation and design exploration on a variety of inputs, while keeping context specific properties such as fairness, proximity to a reference surface, etc. © 2011 ACM.

  11. Obtuse triangle suppression in anisotropic meshes

    KAUST Repository

    Sun, Feng

    2011-12-01

    Anisotropic triangle meshes are used for efficient approximation of surfaces and flow data in finite element analysis, and in these applications it is desirable to have as few obtuse triangles as possible to reduce the discretization error. We present a variational approach to suppressing obtuse triangles in anisotropic meshes. Specifically, we introduce a hexagonal Minkowski metric, which is sensitive to triangle orientation, to give a new formulation of the centroidal Voronoi tessellation (CVT) method. Furthermore, we prove several relevant properties of the CVT method with the newly introduced metric. Experiments show that our algorithm produces anisotropic meshes with much fewer obtuse triangles than using existing methods while maintaining mesh anisotropy. © 2011 Elsevier B.V. All rights reserved.

  12. Mesh Processing in Medical Image Analysis

    DEFF Research Database (Denmark)

    The following topics are dealt with: mesh processing; medical image analysis; interactive freeform modeling; statistical shape analysis; clinical CT images; statistical surface recovery; automated segmentation; cerebral aneurysms; and real-time particle-based representation....

  13. Capacity Analysis of Wireless Mesh Networks

    Directory of Open Access Journals (Sweden)

    M. I. Gumel

    2012-06-01

    Full Text Available The next generation wireless networks experienced a great development with emergence of wireless mesh networks (WMNs, which can be regarded as a realistic solution that provides wireless broadband access. The limited available bandwidth makes capacity analysis of the network very essential. While the network offers broadband wireless access to community and enterprise users, the problems that limit the network capacity must be addressed to exploit the optimum network performance. The wireless mesh network capacity analysis shows that the throughput of each mesh node degrades in order of l/n with increasing number of nodes (n in a linear topology. The degradation is found to be higher in a fully mesh network as a result of increase in interference and MAC layer contention in the network.

  14. Energy-efficient wireless mesh networks

    CSIR Research Space (South Africa)

    Ntlatlapa, N

    2007-06-01

    Full Text Available This paper outlines the objectives of a recently formed research group at Meraka Institute. The authors consider application of wireless mesh networks in rural infrastructure deficient parts of the African continent where nodes operate on batteries...

  15. LR: Compact connectivity representation for triangle meshes

    Energy Technology Data Exchange (ETDEWEB)

    Gurung, T; Luffel, M; Lindstrom, P; Rossignac, J

    2011-01-28

    We propose LR (Laced Ring) - a simple data structure for representing the connectivity of manifold triangle meshes. LR provides the option to store on average either 1.08 references per triangle or 26.2 bits per triangle. Its construction, from an input mesh that supports constant-time adjacency queries, has linear space and time complexity, and involves ordering most vertices along a nearly-Hamiltonian cycle. LR is best suited for applications that process meshes with fixed connectivity, as any changes to the connectivity require the data structure to be rebuilt. We provide an implementation of the set of standard random-access, constant-time operators for traversing a mesh, and show that LR often saves both space and traversal time over competing representations.

  16. Tubing erosion of an inflatable penile prosthesis long after implantation.

    Science.gov (United States)

    Morales, Alvaro

    2014-06-01

    Erosion through skin of connecting tubing of an inflatable penile prosthesis (IPP) has not been previously reported. The aim of this study was to present a case of tubing erosion, review the pertinent literature, and discuss the possible causes and management options, including preservation of the device and its components. A 42-year-old male failing to respond to medical treatment for erectile dysfunction underwent insertion of an AMS 700 IPP in 1986. Six years later, a revision was necessary because of a leak in the right cylinder and 4 years after, the pump was replaced. Fourteen years after the original implant, he presented with a portion of the tube connecting the pump to the right cylinder eroding through the skin. There was no infection. The skin area involved was resected and the original pump and tubing were buried in a new scrotal pocket after thorough irrigation. The IPP remained in place, allowing vaginal penetration and without infection for another 11 years. Three years later, it was de-functionalized, converted into a fixed volume device. It eventually was replaced 25 years after originally implanted with a semirigid prosthesis because it did not provide sufficient rigidity and because of concerns about the presence of "screws" detected during pelvic imaging. Mechanical failures in the early IPP models, as illustrated in this case, were expected. However, the long survival of the device is remarkable. Erosion of the connecting tubing through the skin is unique and, under exceptional circumstances, may be managed conservatively without replacing components of the IPP. Clinicians unfamiliar with procedures involving inflatable devices need to be aware of "foreign bodies" visible in radiological examinations in men who have had revisions of an IPP. Morales A. Tubing erosion of an inflatable penile prosthesis long after implantation. Sex Med 2014;2:103-106.

  17. Reviewing the options for local estrogen treatment of vaginal atrophy

    Directory of Open Access Journals (Sweden)

    Lindahl SH

    2014-03-01

    Full Text Available Sarah H Lindahl Sutter East Bay Medical Foundation, SEBMF – Diablo Division, Castro Valley, CA, USA Background: Vaginal atrophy is a chronic condition with symptoms that include vaginal dryness, pain during sex, itching, irritation, burning, and discharge, as well as various urinary problems. Up to 45% of postmenopausal women may be affected, but it often remains underreported and undertreated. This article aims to review the current recommendations for treatment of vaginal atrophy, and current data on the effectiveness and safety of local vaginal estrogen therapies. Methods: Literature regarding vaginal atrophy (2007–2012 was retrieved from PubMed and summarized, with emphasis on data related to the treatment of vaginal atrophy with local vaginal estrogen therapy. Results: Published data support the effectiveness and endometrial safety of low-dose local estrogen therapies. These results further support the general recommendation by the North American Menopause Society that a progestogen is not needed for endometrial protection in patients using low-dose local vaginal estrogen. Benefits of long-term therapy for vaginal atrophy include sustained relief of symptoms as well as physiological improvements (eg, decreased vaginal pH and increased blood flow, epithelial thickness, secretions. Conclusion: Currently available local vaginal estrogen therapies are well tolerated and effective in relieving symptoms of vaginal atrophy. Recent data support the endometrial safety of low-dose regimens for up to 1 year. Keywords: menopause, estrogen, local estrogen therapy, vaginal atrophy

  18. [Clinical characteristics of aerobic vaginitis and its mixed infections].

    Science.gov (United States)

    Fan, Ai-Ping; Xue, Feng-Xia

    2010-12-01

    To investigate clinical characteristics of aerobic vaginitis (AV) and its mixed infections for diagnosis efficiently. From April 2008 to December 2008, 516 patients with vaginitis treated in Tianjin Medical University General Hospital were enrolled in this study. AV, bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), trichomonal vaginitis (TV), and cytolytic vaginosis (CV) were diagnosed based on symptoms, sign and vaginal discharge examination. Among 516 cases, AV cases were found in 14.7% (76/516), and AV was common vaginal infection. AV mixed infections was diagnosed in 58% (44/76), including mixed with BV (45%, 20/44), mixed with VVC (30%, 13/44), and mixed with TV (25%, 11/44). Those common symptom of AV were yellow vaginal discharge (63%, 20/32), more vaginal discharge (44%, 14/32). Vaginal pH value was usually more than 4.5 (84%, 27/32). Vaginal cleanliness mainly was grade III - IV (88%, 28/32). Six cases with enterococcus faecium and 4 cases with streptococci were frequently isolated. The symptom and sign of mixed AV infection was atypical. Aerobic vaginitis is a common lower vaginal infection and easily mixed with other pathogens, especially with BV, VVC or TV. When patients were diagnosed with AV or other vaginal infection, it should be mentioned whether those patients have mixed vaginal infection or AV.

  19. Buffer erosion in dilute groundwater

    International Nuclear Information System (INIS)

    Schatz, T.; Kanerva, N.; Martikainen, J.; Sane, P.; Olin, M.; Seppaelae, A.; Koskinen, K.

    2013-08-01

    One scenario of interest for repository safety assessment involves the loss of bentonite buffer material in contact with dilute groundwater flowing through a transmissive fracture interface. In order to examine the extrusion/erosion behavior of bentonite buffer material under such circumstances, a series of experiments were performed in a flow-through, 1 mm aperture, artificial fracture system. These experiments covered a range of solution chemistry (salt concentration and composition), material composition (sodium montmorillonite and admixtures with calcium montmorillonite), and flow velocity conditions. No erosion was observed for sodium montmorillonite against solution compositions from 0.5 g/L to 10 g/L NaCl. No erosion was observed for 50/50 calcium/sodium montmorillonite against 0.5 g/L NaCl. Erosion was observed for both sodium montmorillonite and 50/50 calcium/sodium montmorillonite against solution compositions ≤ 0.25 g/L NaCl. The calculated erosion rates for the tests with the highest levels of measured erosion, i.e., the tests run under the most dilute conditions (ionic strength (IS) < ∼1 mM), were well-correlated to flow velocity, whereas the calculated erosion rates for the tests with lower levels of measured erosion, i.e., the tests run under somewhat less dilute conditions (∼1 mM < IS < ∼4 mM), were not similarly correlated indicating that material and solution composition can significantly affect erosion rates. In every experiment, both erosive and non-erosive, emplaced buffer material extruded into the fracture and was observed to be impermeable to water flowing in the fracture effectively forming an extended diffusive barrier around the intersecting fracture/buffer interface. Additionally, a model which was developed previously to predict the rate of erosion of bentonite buffer material in low ionic strength water in rock fracture environments was applied to three different cases: sodium montmorillonite expansion in a vertical tube, a

  20. MHD simulations on an unstructured mesh

    International Nuclear Information System (INIS)

    Strauss, H.R.; Park, W.; Belova, E.; Fu, G.Y.; Sugiyama, L.E.

    1998-01-01

    Two reasons for using an unstructured computational mesh are adaptivity, and alignment with arbitrarily shaped boundaries. Two codes which use finite element discretization on an unstructured mesh are described. FEM3D solves 2D and 3D RMHD using an adaptive grid. MH3D++, which incorporates methods of FEM3D into the MH3D generalized MHD code, can be used with shaped boundaries, which might be 3D

  1. Towards Blockchain-enabled Wireless Mesh Networks

    OpenAIRE

    Selimi, Mennan; Kabbinale, Aniruddh Rao; Ali, Anwaar; Navarro, Leandro; Sathiaseelan, Arjuna

    2018-01-01

    Recently, mesh networking and blockchain are two of the hottest technologies in the telecommunications industry. Combining both can reformulate internet access and make connecting to the Internet not only easy, but affordable too. Hyperledger Fabric (HLF) is a blockchain framework implementation and one of the Hyperledger projects hosted by The Linux Foundation. We evaluate HLF in a real production mesh network and in the laboratory, quantify its performance, bottlenecks and limitations of th...

  2. Unstructured Mesh Movement and Viscous Mesh Generation for CFD-Based Design Optimization, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovations proposed are twofold: 1) a robust unstructured mesh movement method able to handle isotropic (Euler), anisotropic (viscous), mixed element (hybrid)...

  3. MHD simulations on an unstructured mesh

    International Nuclear Information System (INIS)

    Strauss, H.R.; Park, W.

    1996-01-01

    We describe work on a full MHD code using an unstructured mesh. MH3D++ is an extension of the PPPL MH3D resistive full MHD code. MH3D++ replaces the structured mesh and finite difference / fourier discretization of MH3D with an unstructured mesh and finite element / fourier discretization. Low level routines which perform differential operations, solution of PDEs such as Poisson's equation, and graphics, are encapsulated in C++ objects to isolate the finite element operations from the higher level code. The high level code is the same, whether it is run in structured or unstructured mesh versions. This allows the unstructured mesh version to be benchmarked against the structured mesh version. As a preliminary example, disruptions in DIIID reverse shear equilibria are studied numerically with the MH3D++ code. Numerical equilibria were first produced starting with an EQDSK file containing equilibrium data of a DIII-D L-mode negative central shear discharge. Using these equilibria, the linearized equations are time advanced to get the toroidal mode number n = 1 linear growth rate and eigenmode, which is resistively unstable. The equilibrium and linear mode are used to initialize 3D nonlinear runs. An example shows poloidal slices of 3D pressure surfaces: initially, on the left, and at an intermediate time, on the right

  4. How to model wireless mesh networks topology

    International Nuclear Information System (INIS)

    Sanni, M L; Hashim, A A; Anwar, F; Ali, S; Ahmed, G S M

    2013-01-01

    The specification of network connectivity model or topology is the beginning of design and analysis in Computer Network researches. Wireless Mesh Networks is an autonomic network that is dynamically self-organised, self-configured while the mesh nodes establish automatic connectivity with the adjacent nodes in the relay network of wireless backbone routers. Researches in Wireless Mesh Networks range from node deployment to internetworking issues with sensor, Internet and cellular networks. These researches require modelling of relationships and interactions among nodes including technical characteristics of the links while satisfying the architectural requirements of the physical network. However, the existing topology generators model geographic topologies which constitute different architectures, thus may not be suitable in Wireless Mesh Networks scenarios. The existing methods of topology generation are explored, analysed and parameters for their characterisation are identified. Furthermore, an algorithm for the design of Wireless Mesh Networks topology based on square grid model is proposed in this paper. The performance of the topology generated is also evaluated. This research is particularly important in the generation of a close-to-real topology for ensuring relevance of design to the intended network and validity of results obtained in Wireless Mesh Networks researches

  5. [Implants for genital prolapse : Contra mesh surgery].

    Science.gov (United States)

    Hampel, C

    2017-12-01

    Alloplastic transvaginal meshes have become very popular in the surgery of pelvic organ prolapse (POP) as did alloplastic suburethral slings in female stress incontinence surgery, but without adequate supporting data. The simplicity of the mesh procedure facilitates its propagation with acceptance of higher revision and complication rates. Since attending physicians do more and more prolapse surgeries without practicing or teaching alternative techniques, expertise in these alternatives, which might be very useful in cases of recurrence, persistence or complications, is permanently lost. It is doubtful that proper and detailed information about alternatives, risks, and benefits of transvaginal alloplastic meshes is provided to every single prolapse patient according to the recommendations of the German POP guidelines, since the number of implanted meshes exceeds the number of properly indicated mesh candidates by far. Although there is no dissent internationally about the available mesh data, thousands of lawsuits in the USA, insolvency of companies due to claims for compensation and unambiguous warnings from foreign urological societies leave German urogynecologists still unimpressed. The existing literature in pelvic organ prolapse exclusively focusses on POP stage and improvement of that stage with surgical therapy. Instead, typical prolapse symptoms should trigger therapy and improvement of these symptoms should be the utmost treatment goal. It is strongly recommended for liability reasons to obtain specific written informed consent.

  6. Bacterial vaginosis and vaginal yeast, but not vaginal cleansing, increase HIV-1 acquisition in African women.

    Science.gov (United States)

    van de Wijgert, Janneke H H M; Morrison, Charles S; Cornelisse, Peter G A; Munjoma, Marshall; Moncada, Jeanne; Awio, Peter; Wang, Jing; Van der Pol, Barbara; Chipato, Tsungai; Salata, Robert A; Padian, Nancy S

    2008-06-01

    To evaluate interrelationships between bacterial vaginosis (BV), vaginal yeast, vaginal practices (cleansing and drying/tightening), mucosal inflammation, and HIV acquisition. A multicenter, prospective, observational cohort study was conducted, enrolling 4531 HIV-negative women aged 18 to 35 years attending family planning clinics in Zimbabwe and Uganda. Participants were tested for HIV and reproductive tract infections and were interviewed about vaginal practices every 3 months for 15 to 24 months. BV was measured by Gram stain Nugent scoring, vaginal yeast by wet mount, and mucosal inflammation by white blood cells on Gram stain. HIV incidence was 4.12 and 1.53 per 100 woman-years of follow-up in Zimbabwe and Uganda, respectively (a total of 213 incident infections). Women with BV or vaginal yeast were more likely to acquire HIV, especially if the condition was present at the same visit as the new HIV infection and the visit preceding it (hazard ratio [HR] = 2.50, 95% confidence interval [CI]: 1.68 to 3.72 and HR = 2.97, 95% CI: 1.67 to 5.28 for BV and yeast, respectively). These relationships did not seem to be mediated by mucosal inflammation. Vaginal drying/tightening was associated with HIV acquisition in univariate (HR = 1.49, 95% CI: 1.03 to 2.15) but not multivariate models. Vaginal cleansing was not associated with HIV acquisition. BV and yeast may contribute more to the HIV epidemic than previously thought.

  7. The Comparison of vaginal cream of mixing yogurt, honey and clotrimazole on symptoms of vaginal candidiasis.

    Science.gov (United States)

    Darvishi, Maryam; Jahdi, Fereshteh; Hamzegardeshi, Zeinab; Goodarzi, Saied; Vahedi, Mohsen

    2015-04-03

    Vulvovaginal candidiasis is known as one of the most common fungal infection among women of reproductive age and considered as an important public health problem. In recent years, due to resistance to common antifungal medication, the use of traditional medicine of anti-fungal and herbal treatment increased. Therefore the objective of this study was to determine the effects of vaginal cream, mixture of yogurt and honey and comparing it with clotrimazole vaginal cream on symptoms of Vulvovaginal candidiasis in patients. In this randomized, triple blind clinical trial of 70 non-pregnant women infected with Candidal vulvovaginitis were placed in two groups of Vaginal cream mixed of yogurt and honey recipients (N=35) and clotrimazole vaginal cream (N=35). Both groups were treated for 7 days. At the beginning of study, Clinical and laboratory signs and symptoms were registered 7 and 14 days after treatment by questionnaire, observation form and secretions culture results. Data by chi-square test, t test, McNemar tests were analyzed by SPSS version 21. Significance level of 0.05 was considered. The result of present study reveals the significant differences in symptom improvement of ' yogurt and honey, than clotrimazole group (P0.05) CONCLUSION: This study indicated that he therapeutic effects of vaginal cream, yogurt and honey is not only similar with clotrimazole vaginal cream but more effective in relieving some symptoms of vaginal candidiasis. Therefore, the use of this product can be suggested as an herbal remedy for candida infection treatment.

  8. Vaginal lactobacilli profile in pregnant women with normal & abnormal vaginal flora.

    Science.gov (United States)

    Yeruva, Thirupathaiah; Rajkumar, Hemalatha; Donugama, Vasundhara

    2017-10-01

    Lactobacilli species that are better adapted to vaginal environment of women may colonize better and offer protection against vaginal pathogenic bacteria. In this study, the distribution of common Lactobacillus species was investigated in pregnant women. Sixty seven pregnant women were included in the study and vaginal samples were collected for Gram staining. Women were classified as normal vaginal flora, intermediate flora and bacterial vaginosis (BV) based on Nugent's score. Vaginal samples were also collected for the identification of Lactobacillus spp. by multiplex polymerase chain reaction (PCR) profiling of 16S rDNA amplification method. Lactobacillus crispatus (100%) was the most predominant Lactobacillus spp. present in pregnant women with normal flora, followed by L. iners (77%), L. jensenii (74%) and L. helveticus (60%). While, L. iners was commonly present across groups in women with normal, intermediate or BV flora, L. crispatus, L. jensenii and L. helveticus decreased significantly as the vaginal flora changed to intermediate and BV. In women with BV, except L. iners other species of lactobacilli was less frequently prevalent. Species such as L. rhamnosus, L. fermentum, L. paracasei and L. casei were not detected in any vaginal sample. L. crispatus, L. jensinii and L. helveticus were predominant species in women with normal flora. L. crispatus alone or in combination with L. jensinii and L. helveticus may be evaluated for probiotic properties for the prevention and treatment of BV.

  9. Vaginal rings for delivery of HIV microbicides

    Directory of Open Access Journals (Sweden)

    McCoy CF

    2012-11-01

    Full Text Available R Karl Malcolm, Susan M Fetherston, Clare F McCoy, Peter Boyd, Ian MajorSchool of Pharmacy, Queen's University Belfast, Belfast, UKAbstract: Following the successful development of long-acting steroid-releasing vaginal ring devices for the treatment of menopausal symptoms and contraception, there is now considerable interest in applying similar devices to the controlled release of microbicides against HIV. In this review article, the vaginal ring concept is first considered within the wider context of the early advances in controlled-release technology, before describing the various types of ring device available today. The remainder of the article highlights the key developments in HIV microbicide-releasing vaginal rings, with a particular focus on the dapivirine ring that is presently in late-stage clinical testing.Keywords: controlled release, sustained release, antiretroviral, dapivirine, SILCS diaphragm, silicone elastomer, thermoplastic

  10. Fire performance of basalt FRP mesh reinforced HPC thin plates

    DEFF Research Database (Denmark)

    Hulin, Thomas; Hodicky, Kamil; Schmidt, Jacob Wittrup

    2013-01-01

    An experimental program was carried out to investigate the influence of basalt FRP (BFRP) reinforcing mesh on the fire behaviour of thin high performance concrete (HPC) plates applied to sandwich elements. Samples with BFRP mesh were compared to samples with no mesh, samples with steel mesh...

  11. Protective activity of geranium oil and its component, geraniol, in combination with vaginal washing against vaginal candidiasis in mice.

    Science.gov (United States)

    Maruyama, Naho; Takizawa, Toshio; Ishibashi, Hiroko; Hisajima, Tatsuya; Inouye, Shigeharu; Yamaguchi, Hideyo; Abe, Shigeru

    2008-08-01

    In order to evaluate an effective administration method of essential oils for vaginal candidiasis, efficacy of vaginal application of essential oils against murine experimental candidiasis was investigated. The effect on vaginal inflammation and Candida growth form was also studied. Vaginal candidiasis was established by intravaginal infection of C. albicans to estradiol-treated mice. These mice intravaginally received essential oils such as geranium and tea tree singly or in combination with vaginal washing. Vaginal administration of clotrimazole significantly decreased the number of viable C. albicans cells in the vaginal cavity by itself. In contrast, these essential oils did not lower the cell number. When application of geranium oil or geraniol was combined with vaginal washing, the cell number was decreased significantly. The myeloperoxidase activity assay exhibited the possibility that essential oils worked not only to reduce the viable cell number of C. albicans, but also to improve vaginal inflammation. The smear of vaginal washing suspension suggested that more yeast-form cells appeared in vaginal smears of these oil-treated mice than in control mice. In vitro study showed that a very low concentration (25 microg/ml) of geranium oil and geraniol inhibited mycelial growth, but not yeast growth. Based on these findings, it is estimated that vaginal application of geranium oil or its main component, geraniol, suppressed Candida cell growth in the vagina and its local inflammation when combined with vaginal washing.

  12. Anterior vaginal wall repair (surgical treatment of urinary incontinence) - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100110.htm Anterior vaginal wall repair (surgical treatment of urinary incontinence) - series— ... to slide 4 out of 4 Overview The vaginal opening lies just below the urethral opening, and ...

  13. Preliminary findings on vaginal epithelial cells and body ...

    African Journals Online (AJOL)

    Dr Gatsing

    sahelian zone of. Cameroon, in order to assess vaginal cytology and body temperature variations during oestrous cycle. Swabbing was done daily in the vagina, and vaginal smears were stained according to Romanowski method.

  14. prevalence and risk factors for vaginal candidiasis among women

    African Journals Online (AJOL)

    hi-tech

    2005-03-01

    Mar 1, 2005 ... Conculsion: The high prevalence of vaginal candidiasis among women with genital infections ... complaints of either abnormal vaginal discharge, lower abdominal or pelvic ..... is in keeping with the reports in literature (8). The.

  15. Pregnancy's stronghold on the vaginal microbiome.

    Directory of Open Access Journals (Sweden)

    Marina R S Walther-António

    Full Text Available To assess the vaginal microbiome throughout full-term uncomplicated pregnancy.Vaginal swabs were obtained from twelve pregnant women at 8-week intervals throughout their uncomplicated pregnancies. Patients with symptoms of vaginal infection or with recent antibiotic use were excluded. Swabs were obtained from the posterior fornix and cervix at 8-12, 17-21, 27-31, and 36-38 weeks of gestation. The microbial community was profiled using hypervariable tag sequencing of the V3-V5 region of the 16S rRNA gene, producing approximately 8 million reads on the Illumina MiSeq.Samples were dominated by a single genus, Lactobacillus, and exhibited low species diversity. For a majority of the patients (n = 8, the vaginal microbiome was dominated by Lactobacillus crispatus throughout pregnancy. Two patients showed Lactobacillus iners dominance during the course of pregnancy, and two showed a shift between the first and second trimester from L. crispatus to L. iners dominance. In all of the samples only these two species were identified, and were found at an abundance of higher than 1% in this study. Comparative analyses also showed that the vaginal microbiome during pregnancy is characterized by a marked dominance of Lactobacillus species in both Caucasian and African-American subjects. In addition, our Caucasian subject population clustered by trimester and progressed towards a common attractor while African-American women clustered by subject instead and did not progress towards a common attractor.Our analyses indicate normal pregnancy is characterized by a microbiome that has low diversity and high stability. While Lactobacillus species strongly dominate the vaginal environment during pregnancy across the two studied ethnicities, observed differences between the longitudinal dynamics of the analyzed populations may contribute to divergent risk for pregnancy complications. This helps establish a baseline for investigating the role of the microbiome in

  16. Vesicovaginal fistula repair through vaginal approach

    International Nuclear Information System (INIS)

    Ashraf, S.; Rahim, J.

    2014-01-01

    Objectives: To evaluate the outcome of trans-vaginal repair of vesico-vaginal fistula through vaginal approach. Study Design: Prospective study. Material and Methods: This study was carried out in Department of Urology, Shaikh Zayed Postgraduate Medical Institute and National institute of Kidney Diseases, Lahore for the period extending from April 2009 to April 2014. Total 17 patients were included in the study. History, physical examination and findings on investigations were reviewed. In all patients cystoscopy and vaginal examination was performed to see fistula site and ureteral orfices. Then trans-vaginal repair was done in all cases. Results: VVF repair was performed on 17 patients aging 25 to 45 years (mean 35.83 ± 7.37 years). The symptoms preceded for a period of 3 months to 8 years. The cause was gynecological hysterectomy 8 (47.05%), obstetric C-section 7 (41.17%) and obstructed labor 2(11.76%). In three of our patients VVF was previously repaired trans-abdominally. On cystoscopy no patients had more than one fistula. In two (11.76%) patients fistula was supratrigonal. The average size of fistula was 2.05 em, detail of fistula site and size is given in table. One patient had leakage on second postop day that was managed with change of Foleys catheter. Successful repair was achieved in all patients and no patient required second attempt. No ureteric injury and other complications were observed. Conclusion: Trans-vaginal repair of VVF avoid laparotomy and bladder bisection. It has reduced hospital stay and morbidity. (author)

  17. Erosive tooth wear in children

    NARCIS (Netherlands)

    Carvalho, T.S.; Lussi, A.; Jaeggi, T.; Gambon, D.L.; Lussi, A.; Ganss, C.

    2014-01-01

    Erosive tooth wear in children is a common condition. Besides the anatomical differences between deciduous and permanent teeth, additional histological differences may influence their susceptibility to dissolution. Considering laboratory studies alone, it is not clear whether deciduous teeth are

  18. Erosion-resistant composite material

    Science.gov (United States)

    Finch, C.B.; Tennery, V.J.; Curlee, R.M.

    A highly erosion-resistant composite material is formed of chemical vapor-deposited titanium diboride on a sintered titanium diboride-nickel substrate. This material may be suitable for use in cutting tools, coal liquefaction systems, etc.

  19. Soil Erosion and Agricultural Sustainability

    Science.gov (United States)

    Montgomery, D. R.

    2009-04-01

    Data drawn from a global compilation of studies support the long articulated contention that erosion rates from conventionally plowed agricultural fields greatly exceed rates of soil production, erosion under native vegetation, and long-term geological erosion. Whereas data compiled from around the world show that soil erosion under conventional agriculture exceeds both rates of soil production and geological erosion rates by up to several orders of magnitude, similar global distributions of soil production and geological erosion rates suggest an approximate balance. Net soil erosion rates in conventionally plowed fields on the order of 1 mm/yr can erode typical hillslope soil profiles over centuries to millennia, time-scales comparable to the longevity of major civilizations. Well-documented episodes of soil loss associated with agricultural activities date back to the introduction of erosive agricultural methods in regions around the world, and stratigraphic records of accelerated anthropogenic soil erosion have been recovered from lake, fluvial, and colluvial stratigraphy, as well as truncation of soil stratigraphy (such as truncated A horizons). A broad convergence in the results from studies based on various approaches employed to study ancient soil loss and rates of downstream sedimentation implies that widespread soil loss has accompanied human agricultural intensification in examples drawn from around the world. While a broad range of factors, including climate variability and society-specific social and economic contexts — such as wars or colonial relationships — all naturally influence the longevity of human societies, the ongoing loss of topsoil inferred from studies of soil erosion rates in conventional agricultural systems has obvious long-term implications for agricultural sustainability. Consequently, modern agriculture — and therefore global society — faces a fundamental question over the upcoming centuries. Can an agricultural system

  20. Directed shift of vaginal microbiota induced by vaginal application of sucrose gel in rhesus macaques.

    Science.gov (United States)

    Hu, Kai-tao; Zheng, Jin-xin; Yu, Zhi-jian; Chen, Zhong; Cheng, Hang; Pan, Wei-guang; Yang, Wei-zhi; Wang, Hong-yan; Deng, Qi-wen; Zeng, Zhong-ming

    2015-04-01

    Sucrose gel was used to treat bacterial vaginosis in a phase III clinical trial. However, the changes of vaginal flora after treatment were only examined by Nugent score in that clinical trial, While the vaginal microbiota of rhesus macaques is characterized by anaerobic, Gram-negative bacteria, few lactobacilli, and pH levels above 4.6, similar to the microbiota of patients with bacterial vaginosis. This study is aimed to investigate the change of the vaginal microbiota of rehsus macaques after topical use of sucrose gel to reveal more precisely the bacterial population shift after the topical application of sucrose gel. Sixteen rhesus macaques were treated with 0.5 g sucrose gel vaginally and three with 0.5 g of placebo gel. Vaginal swabs were collected daily following treatment. Vaginal pH levels and Nugent scores were recorded. The composition of the vaginal micotbiota was tested by V3∼V4 16S rDNA metagenomic sequencing. Dynamic changes in the Lactobacillus genus were analyzed by qPCR. The vaginal microbiota of rhesus macaques are dominated by anaerobic Gram-negative bacteria, with few lactobacilli and high pH levels above 4.6. After five days' treatment with topical sucrose gel, the component percentage of Lactobacillus in vaginal microbiota increased from 1.31% to 81.59%, while the component percentage of Porphyromonas decreased from 18.60% to 0.43%, Sneathia decreased from 15.09% to 0.89%, Mobiluncus decreased from 8.23% to 0.12%, etc.. The average vaginal pH values of 16 rhesus macaques of the sucrose gel group decreased from 5.4 to 3.89. There were no significant changes in microbiota and vaginal pH observed in the placebo group. Rhesus macaques can be used as animal models of bacterial vaginosis to develop drugs and test treatment efficacy. Furthermore, the topical application of sucrose gel induced the shifting of vaginal flora of rhesus macaques from a BV kind of flora to a lactobacilli-dominating flora. Copyright © 2015 The Authors. Published by

  1. The interaction between vaginal microbiota, cervical length, and vaginal progesterone treatment for preterm birth risk

    OpenAIRE

    Kindinger, Lindsay M.; Bennett, Phillip R.; Lee, Yun S; Marchesi, Julian R.; Smith, Ann; Cacciatore, Stefano; Holmes, Elaine; Nicholson, Jeremy K.; Teoh, T. G.; MacIntyre, David A.

    2017-01-01

    Background Preterm birth is the primary cause of infant death worldwide. A short cervix in the second trimester of pregnancy is a risk factor for preterm birth. In specific patient cohorts, vaginal progesterone reduces this risk. Using 16S rRNA gene sequencing, we undertook a prospective study in women at risk of preterm birth (n?=?161) to assess (1) the relationship between vaginal microbiota and cervical length in the second trimester and preterm birth risk and (2) the impact of vaginal pro...

  2. Parto vaginal tras cesárea

    OpenAIRE

    San Martín Bragado, María

    2016-01-01

    Cuando una mujer ha sido sometida a una cesárea previa existen dos opciones para ella en el caso de que se quede embarazada: repetir cesárea o intentar un parto vaginal. A pesar de los riesgos, el parto vaginal después de una cesárea es una situación atractiva para muchas pacientes y dará lugar a un resultado exitoso en un alto porcentaje de casos. Se ha de tener en cuenta que la realización de una cesárea electiva no está exenta de riesgos Grado en Medicina

  3. Fanconi anemia and vaginal squamous cell carcinoma

    Directory of Open Access Journals (Sweden)

    Jesus Paula Carvalho

    2012-01-01

    Full Text Available Fanconi Anemia (FA is an autosomal recessive disease characterized by chromosome instability, cellular hypersensitivity to DNA cross-linking agents, and increased predisposition to malignancies. We describe here a 28 year-old female with FA and vaginal squamous cell carcinoma treated by radiation therapy alone. The patient developed arm phlebitis, pulmonary fungal infection, and severe rectal bleeding, followed by hypocalcaemia, hypokalemia, vaginal bacterial and fungal infection, with subsequent leg and arm phlebitis, perineal abscess, and sepsis. The patient died 12 weeks later.

  4. [Bacteriological aspects of trichomonal vaginitis (author's transl)].

    Science.gov (United States)

    Brockmann, J; Höhne, C

    1979-01-01

    An analysis was made of the vaginal flora of 25 gynaecological patients with acute trichomomal vaginitis, with the view to elucidating the bacteriological situation. Eighty-four isolates, an average of 3.4 per patient, were taken and included a wide range of aerobic and anaerobic bacteria. - Obligate anaerobic species, such as bacteriodes and peptostreptococci, with susceptibility to metronidazole were among the predominant pathogens. - The differentiated susceptibility of the most common bacteria to antibiotics may yield information useful to therapy in the case of aggravated infection.

  5. Prolapse Recurrence after Transvaginal Mesh Removal.

    Science.gov (United States)

    Rawlings, Tanner; Lavelle, Rebecca S; Coskun, Burhan; Alhalabi, Feras; Zimmern, Philippe E

    2015-11-01

    We determined the rate of pelvic organ prolapse recurrence after transvaginal mesh removal. Following institutional review board approval a longitudinally collected database of women undergoing transvaginal mesh removal for complications after transvaginal mesh placement with at least 1 year minimum followup was queried for pelvic organ prolapse recurrence. Recurrent prolapse was defined as greater than stage 1 on examination or the need for reoperation at the site of transvaginal mesh removal. Outcome measures were based on POP-Q (Pelvic Organ Prolapse Quantification System) at the last visit. Patients were grouped into 3 groups, including group 1--recurrent prolapse in the same compartment as transvaginal mesh removal, 2--persistent prolapse and 3--prolapse in a compartment different than transvaginal mesh removal. Of 73 women 52 met study inclusion criteria from 2007 to 2013, including 73% who presented with multiple indications for transvaginal mesh removal. The mean interval between insertion and removal was 45 months (range 10 to 165). Overall mean followup after transvaginal mesh removal was 30 months (range 12 to 84). In group 1 (recurrent prolapse) the rate was 15% (6 of 40 patients). Four women underwent surgery for recurrent prolapse at a mean 7 of months (range 5 to 10). Two patients elected observation. The rate of persistent prolapse (group 2) was 23% (12 of 52 patients). Three women underwent prolapse reoperation at a mean of 10 months (range 8 to 12). In group 3 (de novo/different compartment prolapse) the rate was 6% (3 of 52 patients). One woman underwent surgical repair at 52 months. At a mean 2.5-year followup 62% of patients (32 of 52) did not have recurrent or persistent prolapse after transvaginal mesh removal and 85% (44 of 52) did not undergo any further procedure for prolapse. Specifically for pelvic organ prolapse in the same compartment as transvaginal mesh removal 12% of patients had recurrence, of whom 8% underwent prolapse repair

  6. Erosion properties of unipolar arcs

    International Nuclear Information System (INIS)

    Chekalin, Eh.K.

    1982-01-01

    Processes modelling the formation of unipolar arcs on the elements of the first wall in limiters of the vacuum chamber and on active elements of tokamak divertor, are experimentally investigated. Erosion, processes that take place at two types of non-stationary cathode spots are considered. Experimental data prove the possibility of reducing erosion intensity by coating the surface of electrodes by oxide films, reduction of the temperature of electrode and discharge current

  7. DES Prediction of Cavitation Erosion and Its Validation for a Ship Scale Propeller

    Science.gov (United States)

    Ponkratov, Dmitriy, Dr

    2015-12-01

    Lloyd's Register Technical Investigation Department (LR TID) have developed numerical functions for the prediction of cavitation erosion aggressiveness within Computational Fluid Dynamics (CFD) simulations. These functions were previously validated for a model scale hydrofoil and ship scale rudder [1]. For the current study the functions were applied to a cargo ship's full scale propeller, on which the severe cavitation erosion was reported. The performed Detach Eddy Simulation (DES) required a fine computational mesh (approximately 22 million cells), together with a very small time step (2.0E-4 s). As the cavitation for this type of vessel is primarily caused by a highly non-uniform wake, the hull was also included in the simulation. The applied method under predicted the cavitation extent and did not fully resolve the tip vortex; however, the areas of cavitation collapse were captured successfully. Consequently, the developed functions showed a very good prediction of erosion areas, as confirmed by comparison with underwater propeller inspection results.

  8. Feature-Sensitive Tetrahedral Mesh Generation with Guaranteed Quality

    OpenAIRE

    Wang, Jun; Yu, Zeyun

    2012-01-01

    Tetrahedral meshes are being extensively used in finite element methods (FEM). This paper proposes an algorithm to generate feature-sensitive and high-quality tetrahedral meshes from an arbitrary surface mesh model. A top-down octree subdivision is conducted on the surface mesh and a set of tetrahedra are constructed using adaptive body-centered cubic (BCC) lattices. Special treatments are given to the tetrahedra near the surface such that the quality of the resulting tetrahedral mesh is prov...

  9. Wind erosion of soils burned by wildfire

    Science.gov (United States)

    N. S. Wagenbrenner; M. J. Germino; B. K. Lamb; R. B. Foltz; P. R. Robichaud

    2011-01-01

    Wind erosion and aeolian transport processes are largely unstudied in the post-wildfire environment, but recent studies have shown that wind erosion can play a major role in burned landscapes. A wind erosion monitoring system was installed immediately following a wildfire in southeastern Idaho, USA to measure wind erosion from the burned area (Figure 1). This paper...

  10. a case report of premenarchial transverse vaginal septum

    African Journals Online (AJOL)

    Premenarchial Transverse vaginal septum is a benign condition. The septum may be ... She had surgical resection of the vaginal septum and a vaginal stent was left in-situ to ... suggested to prevent stenosis described the use of high pressure ...

  11. Prevalence of Vaginal Candidiasis among Pregnant Women with ...

    African Journals Online (AJOL)

    BACKGROUND: Pregnancy represents a risk factor in the occurrence of vaginal candidiasis. OBJECTIVES: To determine the prevalence and clinical features associated with abnormal vaginal discharge and C. albicans infection in pregnant women. METHODS: High vaginal swab samples and data on epidemiological ...

  12. Prepubertal vaginal discharge: Vaginoscopy to rule out foreign body.

    Science.gov (United States)

    Ekinci, Saniye; Karnak, İbrahim; Tanyel, Feridun Cahit; Çiftçi, Arbay Özden

    2016-01-01

    Medical records of all prepubertal patients who underwent vaginoscopy to rule out vaginal foreign body between 2004 and 2013 were reviewed retrospectively. All patients were evaluated by pediatricians prior to surgical consultation. Vaginoscopy is performed in the operating room under general anesthesia. During the study period, 20 girls with persistent vaginal discharge with a mean age of 6.8 years (1-13 years) underwent vaginoscopy to rule out vaginal foreign body. Six patients had bloody vaginal discharge and 4 had recurrent vaginal bleeding lasting for more than one month. Ten patients had purulent vaginal discharge lasting for 1-7 months. None of vaginal cultures revealed pathological bacteria or candida species. Preoperative imaging techniques revealed vaginal foreign body in one patient only. Vaginoscopy demonstrated vaginal foreign bodies in four patients. Foreign bodies were grass inflorescence, safety pin and undefined brownish particles (n=2), which may be pieces of toilet paper or feces. There was no complication related to vaginoscopy and removal of foreign body. Hymen integrity was preserved in all patients. Persistent or recurrent vaginal discharge in prepubertal girls should raise the suspect of vaginal foreign body. Continuous flow vaginoscopy is mandatory to detect and remove any vaginal foreign body. Early diagnosis would prevent complications secondary to long-standing foreign bodies.

  13. Vaginal vault drainage after complicated single-port access laparoscopic-assisted vaginal hysterectomy

    Directory of Open Access Journals (Sweden)

    Soo-Jeong Lee

    2017-05-01

    Conclusion: Vaginal vault drainage could be a safe alternative that allows for the management of postoperative morbidity and retains the advantages of minimally invasive surgery after complicated SPA-LAVH.

  14. Lactobacilli Dominance and Vaginal pH: Why is the Human Vaginal Microbiome Unique?

    Directory of Open Access Journals (Sweden)

    Elizabeth A. Miller

    2016-12-01

    Full Text Available The human vaginal microbiome is dominated by bacteria from the genus Lactobacillus, which create an acidic environment thought to protect women against sexually transmitted pathogens and opportunistic infections. Strikingly, lactobacilli dominance appears to be unique to humans; while the relative abundance of lactobacilli in the human vagina is typically >70%, in other mammals lactobacilli rarely comprise more than 1% of vaginal microbiota. Several hypotheses have been proposed to explain humans' unique vaginal microbiota, including humans' distinct reproductive physiology, high risk of STDs, and high risk of microbial complications linked to pregnancy and birth. Here, we test these hypotheses using comparative data on vaginal pH and the relative abundance of lactobacilli in 26 mammalian species and 50 studies (N=21 mammals for pH and 14 mammals for lactobacilli abundance. We found that non-human mammals, like humans, exhibit the lowest vaginal pH during the period of highest estrogen. However, the vaginal pH of non-human mammals is never as low as is typical for humans (median vaginal pH in humans = 4.5; range of pH across all 21 non-human mammals = 5.4 to 7.8. Contrary to disease and obstetric risk hypotheses, we found no significant relationship between vaginal pH or lactobacilli abundance and multiple metrics of STD or birth injury risk (P-values ranged from 0.13 to 0.99. Given the lack of evidence for these hypotheses, we discuss two alternative explanations: the common function hypothesis and a novel hypothesis related to the diet of agricultural humans. Specifically, with regard to diet we propose that high levels of starch in human diets have led to increased levels of glycogen in the vaginal tract, which, in turn, promotes the proliferation of lactobacilli. If true, human diet may have paved the way for a novel, protective microbiome in human vaginal tracts. Overall, our results highlight the need for continuing research on non

  15. Dynamic clinical measurements of voluntary vaginal contractions and autonomic vaginal reflexes.

    Science.gov (United States)

    Broens, Paul M A; Spoelstra, Symen K; Weijmar Schultz, Willibrord C M

    2014-12-01

    The vaginal canal is an active and responsive canal. It has pressure variations along its length and shows reflex activity. At present, the prevailing idea is that the vaginal canal does not have a sphincter mechanism. It is hypothesized that an active vaginal muscular mechanism exists and might be involved in the pathophysiology of genito-pelvic pain/penetration disorder. The aim of this study was to detect the presence of a canalicular vaginal "sphincter mechanism" by measuring intravaginal pressure at different levels of the vaginal canal during voluntary pelvic floor contractions and during induced reflexive contractions. Sixteen nulliparous women, without sexual dysfunction and pelvic floor trauma, were included in the study. High-resolution solid-state circumferential catheters were used to measure intravaginal pressures and vaginal contractions at different levels in the vaginal canal. Voluntary intravaginal pressure measurements were performed in the left lateral recumbent position only, while reflexive intravaginal pressure measurements during slow inflation of a vaginal balloon were performed in the left lateral recumbent position and in the sitting position. Intravaginal pressures and vaginal contractions were the main outcome measures. In addition, a general demographic and medical history questionnaire was administered to gain insight into the characteristics of the study population. Fifteen out of the sixteen women had deep and superficial vaginal high-pressure zones. In one woman, no superficial high-pressure zone was found. The basal and maximum pressures, as well as the duration of the autonomic reflexive contractions significantly exceeded the pressures and the duration of the voluntary contractions. There were no significant differences between the reflexive measurements obtained in the left lateral recumbent and the sitting position. The two high-pressure zones found in this study, as a result of voluntary contractions and, even more pronounced

  16. assisted vaginal hysterectomy versus abdominal hysterectomy on ...

    African Journals Online (AJOL)

    minimal postoperative discomfort and less need for ... the feasibility of registrar training in laparoscopic-assisted vaginal hysterectomy (LAVH), and to investigate the impact of laparoscopy in changing the route of hysterectomy in women assessed as being unsuitable for ... All patients received prophylactic antibiotics during.

  17. Assessment of vaginal atrophy: a review

    NARCIS (Netherlands)

    Weber, M. A.; Limpens, J.; Roovers, J. P. W. R.

    2015-01-01

    The aim of this study is to provide an evidence-based definition of vaginal atrophy (VA) and present an overview of subjective and objective measurements of VA applicable in clinical practice and research. A systematic literature search was performed in MEDLINE and EMBASE to identify studies

  18. Vaginal Lacerations from Consensual Intercourse in Adolescents

    Science.gov (United States)

    Frioux, Sarah M.; Blinman, Thane; Christian, Cindy W.

    2011-01-01

    Objective: (1) To describe lacerations of the vaginal fornices, an injury known to be associated with consensual sexual intercourse, including known complications and treatment course, (2) to contrast these injuries with injuries sustained during sexual assault, and (3) to discuss the assessment of adolescent patients for sexual injuries. Methods:…

  19. The vaginal microflora in relation to gingivitis

    Science.gov (United States)

    2009-01-01

    Background Gingivitis has been linked to adverse pregnancy outcome (APO). Bacterial vaginosis (BV) has been associated with APO. We assessed if bacterial counts in BV is associated with gingivitis suggesting a systemic infectious susceptibilty. Methods Vaginal samples were collected from 180 women (mean age 29.4 years, SD ± 6.8, range: 18 to 46), and at least six months after delivery, and assessed by semi-quantitative DNA-DNA checkerboard hybridization assay (74 bacterial species). BV was defined by Gram stain (Nugent criteria). Gingivitis was defined as bleeding on probing at ≥ 20% of tooth sites. Results A Nugent score of 0–3 (normal vaginal microflora) was found in 83 women (46.1%), and a score of > 7 (BV) in 49 women (27.2%). Gingivitis was diagnosed in 114 women (63.3%). Women with a diagnosis of BV were more likely to have gingivitis (p = 0.01). Independent of gingival conditions, vaginal bacterial counts were higher (p gingivitis had higher counts of Prevotella bivia (p 1.0 × 104 cells) and a diagnosis of gingivitis was 3.9 for P. bivia (95% CI 1.5–5.7, p gingivitis in comparison to women with BV but not gingivitis. P. bivia and P. disiens may be of specific significance in a relationship between vaginal and gingival infections. PMID:19161595

  20. [Severe vaginal discharge following rectal surgery

    NARCIS (Netherlands)

    Burg, L.C.; Bremers, A.J.A.; Heesakkers, J.P.; Kluivers, K.B.

    2018-01-01

    BACKGROUND: Almost 50% of women who have had rectal surgery subsequently develop vaginal discharge. Due to the recurrent and unexpected nature of this heavy discharge, they often experience it as very distressing. Many of these women undergo extensive diagnostic tests that are mainly focused on

  1. An isolated vaginal metastasis from rectal cancer

    Directory of Open Access Journals (Sweden)

    Ai Sadatomo

    2016-02-01

    Conclusion: We should keep the vagina within the field of view of pelvic MRI, which is one of the preoperative diagnostic tools for colorectal cancer. If female patients show gynecological symptoms, gynecological examination should be recommended. Isolated vaginal metastases are an indication for surgical resection, and adjuvant chemotherapy is also recommended.

  2. Predictors of vaginal delivery in nulliparous mothers

    African Journals Online (AJOL)

    physical characteristics such as height and weight, events in labor and mode of ... maternal BMI, fetal head engagement and normal range of fetal birth weight were .... gestational age at booking, height, weight, fetal ... study due to: Hypertensive disorders of pregnancy ... vaginal delivery compared with overweight or obese.

  3. Bioadhesive Controlled Release Clotrimazole Vaginal Tablets | Bhat ...

    African Journals Online (AJOL)

    Conclusion: This study indicates the possible use of suitable mixtures of natural and semi-synthetic cellulosic polymers for the preparation of clotrimazole mucoadhesive tablets for application as a vaginal controlled delivery system. Keywords: Clotrimazole, Swelling, Cellulosic polymers, Guar gum, Bioadhesion, Release ...

  4. Vaginal foreign body causing recurrent discharge and vaginal stenosis--a case report.

    Science.gov (United States)

    Gurung, Geeta; Rana, Ashma; Amatya, Archana

    2007-06-01

    Chronic vaginal discharge in children and adolescents is a common gynaecological complaint which is often resistant to antibiotic treatment. We present a 14 years old, premenarcheal girl who presented to us with the complaints of recurrent, foul smelling purulent occasionally blood stained vaginal discharge for eight years, where a foreign body in the upper vagina was found after releasing a dense adhesion of the lower vagina which was unable to detect by pelvic ultrasound.

  5. Cartesian anisotropic mesh adaptation for compressible flow

    International Nuclear Information System (INIS)

    Keats, W.A.; Lien, F.-S.

    2004-01-01

    Simulating transient compressible flows involving shock waves presents challenges to the CFD practitioner in terms of the mesh quality required to resolve discontinuities and prevent smearing. This paper discusses a novel two-dimensional Cartesian anisotropic mesh adaptation technique implemented for compressible flow. This technique, developed for laminar flow by Ham, Lien and Strong, is efficient because it refines and coarsens cells using criteria that consider the solution in each of the cardinal directions separately. In this paper the method will be applied to compressible flow. The procedure shows promise in its ability to deliver good quality solutions while achieving computational savings. The convection scheme used is the Advective Upstream Splitting Method (Plus), and the refinement/ coarsening criteria are based on work done by Ham et al. Transient shock wave diffraction over a backward step and shock reflection over a forward step are considered as test cases because they demonstrate that the quality of the solution can be maintained as the mesh is refined and coarsened in time. The data structure is explained in relation to the computational mesh, and the object-oriented design and implementation of the code is presented. Refinement and coarsening algorithms are outlined. Computational savings over uniform and isotropic mesh approaches are shown to be significant. (author)

  6. Mesh networks: an optimum solution for AMR

    Energy Technology Data Exchange (ETDEWEB)

    Mimno, G.

    2003-12-01

    Characteristics of mesh networks and the advantage of using them in automatic meter reading equipment (AMR) are discussed. Mesh networks are defined as being similar to a fishing net made of knots and links. In mesh networks the knots represent meter sites and the links are the radio paths between the meter sites and the neighbourhood concentrator. In mesh networks any knot in the communications chain can link to any other and the optimum path is calculated by the network by hopping from meter to meter until the radio message reaches a concentrator. This mesh communications architecture is said to be vastly superior to many older types of radio-based meter reading technologies; its main advantage is that it not only significantly improves the economics of fixed network deployment, but also supports time-of-use metering, remote disconnect services and advanced features, such as real-time pricing, demand response, and other efficiency measures, providing a better return on investment and reliability.

  7. Coupling LaGrit unstructured mesh generation and model setup with TOUGH2 flow and transport: A case study

    Science.gov (United States)

    Sentís, Manuel Lorenzo; Gable, Carl W.

    2017-11-01

    There are many applications in science and engineering modeling where an accurate representation of a complex model geometry in the form of a mesh is important. In applications of flow and transport in subsurface porous media, this is manifest in models that must capture complex geologic stratigraphy, structure (faults, folds, erosion, deposition) and infrastructure (tunnels, boreholes, excavations). Model setup, defined as the activities of geometry definition, mesh generation (creation, optimization, modification, refine, de-refine, smooth), assigning material properties, initial conditions and boundary conditions requires specialized software tools to automate and streamline the process. In addition, some model setup tools will provide more utility if they are designed to interface with and meet the needs of a particular flow and transport software suite. A control volume discretization that uses a two point flux approximation is for example most accurate when the underlying control volumes are 2D or 3D Voronoi tessellations. In this paper we will present the coupling of LaGriT, a mesh generation and model setup software suite and TOUGH2 (Pruess et al., 1999) to model subsurface flow problems and we show an example of how LaGriT can be used as a model setup tool for the generation of a Voronoi mesh for the simulation program TOUGH2. To generate the MESH file for TOUGH2 from the LaGriT output a standalone module Lagrit2Tough2 was developed, which is presented here and will be included in a future release of LaGriT. In this paper an alternative method to generate a Voronoi mesh for TOUGH2 with LaGriT is presented and thanks to the modular and command based structure of LaGriT this method is well suited to generating a mesh for complex models.

  8. In Vitro Activity of Tea Tree Oil Vaginal Suppositories against Candida spp. and Probiotic Vaginal Microbiota.

    Science.gov (United States)

    Di Vito, Maura; Mattarelli, Paola; Modesto, Monica; Girolamo, Antonietta; Ballardini, Milva; Tamburro, Annunziata; Meledandri, Marcello; Mondello, Francesca

    2015-10-01

    The aim of this work is to evaluate the in vitro microbicidal activity of vaginal suppositories (VS) containing tea tree oil (TTO-VS) towards Candida spp. and vaginal probiotics. A total of 20 Candida spp. strains, taken from patients with vaginitis and from an established type collection, including reference strains, were analysed by using the CLSI microdilution method. To study the action of VS towards the beneficial vaginal microbiota, the sensitivity of Bifidobacterium animalis subsp. lactis (DSM 10140) and Lactobacillus spp. (Lactobacillus casei R-215 and Lactobacillus acidophilus R-52) was tested. Both TTO-VS and TTO showed fungicidal activity against all strains of Candida spp. whereas placebo-VS or the Aloe gel used as controls were ineffective. The study of fractional fungicidal concentrations (FFC) showed synergistic interaction with the association between Amphotericin B and TTO (0.25 to 0.08 µg/ml, respectively) against Candida albicans. Instead, the probiotics were only affected by TTO concentration ≥ 4% v/v, while, at concentrations vaginal microbiota. In vivo studies are needed to confirm the efficacy to prevent acute or recurrent vaginal candidiasis. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Sonic anemometry and sediment traps to evaluate the effectiveness of windbreaks in preventing wind erosion

    Directory of Open Access Journals (Sweden)

    Alejandro López

    Full Text Available ABSTRACT The present work analyzes the effectiveness of windbreaks against wind erosion through the study of streamline patterns and turbulent flow by means of sonic anemometry and sediment traps. To this end, windbreaks composed of plastic meshes (7.5 m long and 0.7 m tall were used. Windbreaks are a good means to reduce wind erosion, as they produce a positive effect on the characteristics of air currents that are related to wind erosion processes. Due to their ease of installation and dismantling, plastic meshes are widely used in areas where they are not required permanently. In our study, the use of a mesh of 13 × 30 threads cm−2 and 39 % porosity resulted in an average reduction of 85 % in face velocity at a height of 0.4 m and a distance of 1 m from the windbreak. The turbulence intensity i increased behind the windbreak because the reduction of mean of air speed on the leeside caused by the flow of air through the windbreak. Fluctuation levels, however, remained stable. The mean values of turbulence kinetic energy k decreased by 65 % to 86 % at a distance of 1 m from the windbreak and at a height of 0.4 m. The windbreak reduces erosion and sediment transportation 2 m downwind (2.9 times the windbreak height. Nevertheless, sediment transportation was not reduced at a height of 1.0 m and the effect of the windbreak was not observed at a distance of 6 m downwind (8.6 m times the windbreak height.

  10. Connectivity editing for quad-dominant meshes

    KAUST Repository

    Peng, Chihan

    2013-08-01

    We propose a connectivity editing framework for quad-dominant meshes. In our framework, the user can edit the mesh connectivity to control the location, type, and number of irregular vertices (with more or fewer than four neighbors) and irregular faces (non-quads). We provide a theoretical analysis of the problem, discuss what edits are possible and impossible, and describe how to implement an editing framework that realizes all possible editing operations. In the results, we show example edits and illustrate the advantages and disadvantages of different strategies for quad-dominant mesh design. © 2013 The Author(s) Computer Graphics Forum © 2013 The Eurographics Association and John Wiley & Sons Ltd.

  11. ZONE: a finite element mesh generator

    International Nuclear Information System (INIS)

    Burger, M.J.

    1976-05-01

    The ZONE computer program is a finite-element mesh generator which produces the nodes and element description of any two-dimensional geometry. The geometry is subdivided into a mesh of quadrilateral and triangular zones arranged sequentially in an ordered march through the geometry. The order of march can be chosen so that the minimum bandwidth is obtained. The node points are defined in terms of the x and y coordinates in a global rectangular coordinate system. The zones generated are quadrilaterals or triangles defined by four node points in a counterclockwise sequence. Node points defining the outside boundary are generated to describe pressure boundary conditions. The mesh that is generated can be used as input to any two-dimensional as well as any axisymmetrical structure program. The output from ZONE is essentially the input file to NAOS, HONDO, and other axisymmetric finite element programs. 14 figures

  12. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    Background For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. Data sources...... A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  13. Open preperitoneal groin hernia repair with mesh

    DEFF Research Database (Denmark)

    Andresen, Kristoffer; Rosenberg, Jacob

    2017-01-01

    BACKGROUND: For the repair of inguinal hernias, several surgical methods have been presented where the purpose is to place a mesh in the preperitoneal plane through an open access. The aim of this systematic review was to describe preperitoneal repairs with emphasis on the technique. DATA SOURCES......: A systematic review was conducted and reported according to the PRISMA statement. PubMed, Cochrane library and Embase were searched systematically. Studies were included if they provided clinical data with more than 30 days follow up following repair of an inguinal hernia with an open preperitoneal mesh......-analysis. Open preperitoneal techniques with placement of a mesh through an open approach seem promising compared with the standard anterior techniques. This systematic review provides an overview of these techniques together with a description of surgical methods and clinical outcomes....

  14. Auto consolidated cohesive sediments erosion

    International Nuclear Information System (INIS)

    Ternat, F.

    2007-02-01

    Pollutants and suspended matters of a river can accumulate into the sedimentary column. Once deposited, they are submitted to self-weight consolidation processes, ageing and burying, leading to an increase of their erosion resistance. Pollutant fluxes can be related to sedimentary fluxes, determined by threshold laws. In this work, an erosion threshold model is suggested by introducing a cohesion force into the usual force balance. A model of cohesion is developed on the basis of interactions between argillaceous cohesive particles (clays), particularly the Van der Waals force, whose parameterization is ensured by means of granulometry and porosity. Artificial erosion experiments were performed in a recirculating erosion flume with natural cored sediments where critical shear stress measurements were performed. Other analyses provided granulometry and porosity. The results obtained constitute a good database for the literature. The model is then applied to the experimental conditions and gives good agreement with measurements. An example of the accounting for self-weight consolidation processes is finally suggested, before finishing on a Mohr like diagram dedicated to soft cohesive sediment erosion. (author)

  15. Group B streptococcus exploits vaginal epithelial exfoliation for ascending infection.

    Science.gov (United States)

    Vornhagen, Jay; Armistead, Blair; Santana-Ufret, Verónica; Gendrin, Claire; Merillat, Sean; Coleman, Michelle; Quach, Phoenicia; Boldenow, Erica; Alishetti, Varchita; Leonhard-Melief, Christina; Ngo, Lisa Y; Whidbey, Christopher; Doran, Kelly S; Curtis, Chad; Waldorf, Kristina M Adams; Nance, Elizabeth; Rajagopal, Lakshmi

    2018-04-09

    Thirteen percent of pregnancies result in preterm birth or stillbirth, accounting for fifteen million preterm births and three and a half million deaths annually. A significant cause of these adverse pregnancy outcomes is in utero infection by vaginal microorganisms. To establish an in utero infection, vaginal microbes enter the uterus by ascending infection; however, the mechanisms by which this occurs are unknown. Using both in vitro and murine models of vaginal colonization and ascending infection, we demonstrate how a vaginal microbe, group B streptococcus (GBS), which is frequently associated with adverse pregnancy outcomes, uses vaginal exfoliation for ascending infection. GBS induces vaginal epithelial exfoliation by activation of integrin and β-catenin signaling. However, exfoliation did not diminish GBS vaginal colonization as reported for other vaginal microbes. Rather, vaginal exfoliation increased bacterial dissemination and ascending GBS infection, and abrogation of exfoliation reduced ascending infection and improved pregnancy outcomes. Thus, for some vaginal bacteria, exfoliation promotes ascending infection rather than preventing colonization. Our study provides insight into mechanisms of ascending infection by vaginal microbes.

  16. Atrophic Vaginitis in Breast Cancer Survivors: A Difficult Survivorship Issue

    Directory of Open Access Journals (Sweden)

    Joanne Lester

    2015-03-01

    Full Text Available Management of breast cancer includes systematic therapies including chemotherapy and endocrine therapy can lead to a variety of symptoms that can impair the quality of life of many breast cancer survivors. Atrophic vaginitis, caused by decreased levels of circulating estrogen to urinary and vaginal receptors, is commonly experienced by this group. Chemotherapy induced ovarian failure and endocrine therapies including aromatase inhibitors and selective estrogen receptor modulators can trigger the onset of atrophic vaginitis or exacerbate existing symptoms. Symptoms of atrophic vaginitis include vaginal dryness, dyspareunia, and irritation of genital skin, pruritus, burning, vaginal discharge, and soreness. The diagnosis of atrophic vaginitis is confirmed through patient-reported symptoms and gynecological examination of external structures, introitus, and vaginal mucosa. Lifestyle modifications can be helpful but are usually insufficient to significantly improve symptoms. Non-hormonal vaginal therapies may provide additional relief by increasing vaginal moisture and fluid. Systemic estrogen therapy is contraindicated in breast cancer survivors. Continued investigations of various treatments for atrophic vaginitis are necessary. Local estrogen-based therapies, DHEA, testosterone, and pH-balanced gels continue to be evaluated in ongoing studies. Definitive results are needed pertaining to the safety of topical estrogens in breast cancer survivors.

  17. Vaginal Masses: Magnetic Resonance Imaging Features with Pathologic Correlation

    International Nuclear Information System (INIS)

    Elsayes, K.M.; Narra, V.R.; Dillman, J.R.; Velcheti, V.; Hameed, O.; Tongdee, R.; Menias, C.O.

    2007-01-01

    The detection of vaginal lesions has increased with the expanding use of cross-sectional imaging. Magnetic resonance imaging (MRI) - with its high-contrast resolution and multiplanar capabilities - is often useful for characterizing vaginal masses. Vaginal masses can be classified as congenital, inflammatory, cystic (benign), and neoplastic (benign or malignant) in etiology. Recognition of the typical MR imaging features of such lesions is important because it often determines the treatment approach and may obviate surgery. Finally, vaginal MR imaging can be used to evaluate post-treatment changes related to previous surgery and radiation therapy. In this article, we will review pertinent vaginal anatomy, vaginal and pelvic MRI technique, and the MRI features of a variety of vaginal lesions with pathological correlation

  18. Unstructured Adaptive Meshes: Bad for Your Memory?

    Science.gov (United States)

    Biswas, Rupak; Feng, Hui-Yu; VanderWijngaart, Rob

    2003-01-01

    This viewgraph presentation explores the need for a NASA Advanced Supercomputing (NAS) parallel benchmark for problems with irregular dynamical memory access. This benchmark is important and necessary because: 1) Problems with localized error source benefit from adaptive nonuniform meshes; 2) Certain machines perform poorly on such problems; 3) Parallel implementation may provide further performance improvement but is difficult. Some examples of problems which use irregular dynamical memory access include: 1) Heat transfer problem; 2) Heat source term; 3) Spectral element method; 4) Base functions; 5) Elemental discrete equations; 6) Global discrete equations. Nonconforming Mesh and Mortar Element Method are covered in greater detail in this presentation.

  19. Local adaptive mesh refinement for shock hydrodynamics

    International Nuclear Information System (INIS)

    Berger, M.J.; Colella, P.; Lawrence Livermore Laboratory, Livermore, 94550 California)

    1989-01-01

    The aim of this work is the development of an automatic, adaptive mesh refinement strategy for solving hyperbolic conservation laws in two dimensions. There are two main difficulties in doing this. The first problem is due to the presence of discontinuities in the solution and the effect on them of discontinuities in the mesh. The second problem is how to organize the algorithm to minimize memory and CPU overhead. This is an important consideration and will continue to be important as more sophisticated algorithms that use data structures other than arrays are developed for use on vector and parallel computers. copyright 1989 Academic Press, Inc

  20. Adaptive mesh refinement for storm surge

    KAUST Repository

    Mandli, Kyle T.; Dawson, Clint N.

    2014-01-01

    An approach to utilizing adaptive mesh refinement algorithms for storm surge modeling is proposed. Currently numerical models exist that can resolve the details of coastal regions but are often too costly to be run in an ensemble forecasting framework without significant computing resources. The application of adaptive mesh refinement algorithms substantially lowers the computational cost of a storm surge model run while retaining much of the desired coastal resolution. The approach presented is implemented in the GeoClaw framework and compared to ADCIRC for Hurricane Ike along with observed tide gauge data and the computational cost of each model run. © 2014 Elsevier Ltd.

  1. MUSIC: a mesh-unrestricted simulation code

    International Nuclear Information System (INIS)

    Bonalumi, R.A.; Rouben, B.; Dastur, A.R.; Dondale, C.S.; Li, H.Y.H.

    1978-01-01

    A general formalism to solve the G-group neutron diffusion equation is described. The G-group flux is represented by complementing an ''asymptotic'' mode with (G-1) ''transient'' modes. A particular reduction-to-one-group technique gives a high computational efficiency. MUSIC, a 2-group code using the above formalism, is presented. MUSIC is demonstrated on a fine-mesh calculation and on 2 coarse-mesh core calculations: a heavy-water reactor (HWR) problem and the 2-D lightwater reactor (LWR) IAEA benchmark. Comparison is made to finite-difference results

  2. Adaptive mesh refinement for storm surge

    KAUST Repository

    Mandli, Kyle T.

    2014-03-01

    An approach to utilizing adaptive mesh refinement algorithms for storm surge modeling is proposed. Currently numerical models exist that can resolve the details of coastal regions but are often too costly to be run in an ensemble forecasting framework without significant computing resources. The application of adaptive mesh refinement algorithms substantially lowers the computational cost of a storm surge model run while retaining much of the desired coastal resolution. The approach presented is implemented in the GeoClaw framework and compared to ADCIRC for Hurricane Ike along with observed tide gauge data and the computational cost of each model run. © 2014 Elsevier Ltd.

  3. Bentonite erosion. Laboratory studies

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, Mats (Div. of Nuclear Chemistry, Royal Inst. of Technology, Stockholm (Sweden), School of Chemical Science and Engineering)

    2009-11-15

    This report covers the laboratory studies that have been performed at Nuclear Chemistry, KTH in the project 'Bentonite Erosion'. Many of the experiments in this report were performed to support the work of the modelling group and were often relatively simple. One of the experiment series was performed to see the impact of gravity and concentration of mono- and di-valent cations. A clay suspension was prepared in a test tube. A net was placed in contact with the suspension, the test tube was filled with solutions of different concentrations and the system was left overnight to settle. The tube was then turned upside down and the behaviour was visually observed. Either the clay suspension fell through the net or stayed on top. By using this method surprisingly sharp determinations of the Critical Coagulation (Flocculation) Concentration (CCC/CFC) could be made. The CCC/CFC of Ca2+ was for sodium montmorillonite determined to be between 1 and 2 mM. An artificial fracture was manufactured in order to simulate the real case scenario. The set-up was two Plexiglas slabs separated by 1 mm thick spacers with a bentonite container at one side of the fracture. Water was pumped with a very low flow rate perpendicular to bentonite container and the water exiting the fracture was sampled and analyzed for colloid content. The bentonite used was treated in different ways. In the first experiment a relatively montmorillonite rich clay was used while in the second bentonite where only the readily soluble minerals had been removed was used. Since Plexiglas was used it was possible to visually observe the bentonite dispersing into the fracture. After the compacted bentonite (1,000 kg/m3) had been water saturated the clay had expanded some 12 mm out into the fracture. As the experiment progressed the clay expanded more out into the fracture and seemed to fractionate in two different phases with less material in the outmost phase. A dark rim which was later analyzed to contain

  4. Bentonite erosion - Laboratory studies

    International Nuclear Information System (INIS)

    Jansson, Mats

    2010-01-01

    Document available in extended abstract form only. Bentonite clay is proposed as buffer material in the KBS-3 concept of storing spent nuclear fuel. Since the clay is plastic it will protect the canisters containing the spent fuel from movements in the rock. Furthermore, the clay will expand when taking up water, become very compact and hence limit the transport of solutes to and from the canister to only diffusion. The chemical stability of the bentonite barrier is of vital importance. If much material would be lost the barrier will lose its functions. As a side effect, lots of colloids will be released which may facilitate radionuclide transport in case of a breach in the canister. There are scenarios where during an ice age fresh melt water may penetrate down to repository depths with relatively high flow rates and not mix with older waters of high salinity. Under such conditions bentonite colloids will be more stable and there is a possibility that the bentonite buffer would start to disperse and bentonite colloids be carried away by the passing water. This work is a part of a larger project called Bentonite Erosion, initiated and supported by SKB. In this work several minor experiments have been performed in order to investigate the influence of for instance di-valent cations, gravity, etc. on the dispersion behaviour of bentonite and/or montmorillonite. A bigger experiment where the real situation was simulated using an artificial fracture was conducted. Two Plexiglas slabs were placed on top of each other, separated by plastic spacers. Bentonite was placed in a container in contact with a fracture. The bentonite was water saturated before deionized water was pumped through the fracture. The evolution of the bentonite profile in the fracture was followed visually. The eluate was collected in five different slots at the outlet side and analyzed for colloid concentration employing Photon Correlation Spectroscopy (PCS) and a Single Particle Counter (SPC). Some

  5. Mesh size in Lichtenstein repair: a systematic review and meta-analysis to determine the importance of mesh size.

    Science.gov (United States)

    Seker, D; Oztuna, D; Kulacoglu, H; Genc, Y; Akcil, M

    2013-04-01

    Small mesh size has been recognized as one of the factors responsible for recurrence after Lichtenstein hernia repair due to insufficient coverage or mesh shrinkage. The Lichtenstein Hernia Institute recommends a 7 × 15 cm mesh that can be trimmed up to 2 cm from the lateral side. We performed a systematic review to determine surgeons' mesh size preference for the Lichtenstein hernia repair and made a meta-analysis to determine the effect of mesh size, mesh type, and length of follow-up time on recurrence. Two medical databases, PubMed and ISI Web of Science, were systematically searched using the key word "Lichtenstein repair." All full text papers were selected. Publications mentioning mesh size were brought for further analysis. A mesh surface area of 90 cm(2) was accepted as the threshold for defining the mesh as small or large. Also, a subgroup analysis for recurrence pooled proportion according to the mesh size, mesh type, and follow-up period was done. In total, 514 papers were obtained. There were no prospective or retrospective clinical studies comparing mesh size and clinical outcome. A total of 141 papers were duplicated in both databases. As a result, 373 papers were obtained. The full text was available in over 95 % of papers. Only 41 (11.2 %) papers discussed mesh size. In 29 studies, a mesh larger than 90 cm(2) was used. The most frequently preferred commercial mesh size was 7.5 × 15 cm. No papers mentioned the size of the mesh after trimming. There was no information about the relationship between mesh size and patient BMI. The pooled proportion in recurrence for small meshes was 0.0019 (95 % confidence interval: 0.007-0.0036), favoring large meshes to decrease the chance of recurrence. Recurrence becomes more marked when follow-up period is longer than 1 year (p < 0.001). Heavy meshes also decreased recurrence (p = 0.015). This systematic review demonstrates that the size of the mesh used in Lichtenstein hernia repair is rarely

  6. Properties of meshes used in hernia repair: a comprehensive review of synthetic and biologic meshes.

    Science.gov (United States)

    Ibrahim, Ahmed M S; Vargas, Christina R; Colakoglu, Salih; Nguyen, John T; Lin, Samuel J; Lee, Bernard T

    2015-02-01

    Data on the mechanical properties of the adult human abdominal wall have been difficult to obtain rendering manufacture of the ideal mesh for ventral hernia repair a challenge. An ideal mesh would need to exhibit greater biomechanical strength and elasticity than that of the abdominal wall. The aim of this study is to quantitatively compare the biomechanical properties of the most commonly used synthetic and biologic meshes in ventral hernia repair and presents a comprehensive literature review. A narrative review of the literature was performed using the PubMed database spanning articles from 1982 to 2012 including a review of company Web sites to identify all available information relating to the biomechanical properties of various synthetic and biologic meshes used in ventral hernia repair. There exist differences in the mechanical properties and the chemical nature of different meshes. In general, most synthetic materials have greater stiffness and elasticity than what is required for abdominal wall reconstruction; however, each exhibits unique properties that may be beneficial for clinical use. On the contrary, biologic meshes are more elastic but less stiff and with a lower tensile strength than their synthetic counterparts. The current standard of practice for the treatment of ventral hernias is the use of permanent synthetic mesh material. Recently, biologic meshes have become more frequently used. Most meshes exhibit biomechanical properties over the known abdominal wall thresholds. Augmenting strength requires increasing amounts of material contributing to more stiffness and foreign body reaction, which is not necessarily an advantage. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Soil erosion in Slovene Istria

    Directory of Open Access Journals (Sweden)

    Matjaž Mikoš

    2009-12-01

    Full Text Available From the end of nineties of the 20th century, intense hydrologic and geomorphologic research is taking place in the Slovene Istria. As a part of this research also studies on soil erosion were undertaken in the period from 2005 to 2008. The field measurements were under taken onclosed 1m2 large erosion plots under three different land uses (on bare soils in an olive grove, on an overgrown meadow, in a forest, placed south of the Marezige village in the Rokava River basin.We show weekly measurements of surface erosion (interrill erosion for the period of 13 months (the end of March 2005 – the end of April 2006, as well as monthly and seasonal averages together with selected linear statistical correlations between soil erosion and weather parameters.From May 2005 to April 2006 the interrill erosion on bare soils in an olive grove with an inclination of 5.5° amounted to 9013 g/m2 (90 t/ha that corresponds to surface lowering rate of 8.5 mm/yr; on an overgrown meadow with an inclination of 9.4° it amounted to 168 g/m2 (1,68 t/ha that corresponds to surface lowering rate of 0.16 mm//yr; and in a forest with an inclination of 7.8° it amounted to 391 g/m2 (3,91 t/ha and in a forest with an inclination of 21.4° it amounted to 415 g/m2 (4,15 t/ha, respectively, that corresponds to surface lowering rate of 0.4 mm/yr.

  8. To Pack or Not to Pack? A Randomized Trial of Vaginal Packing After Vaginal Reconstructive Surgery.

    Science.gov (United States)

    Westermann, Lauren B; Crisp, Catrina C; Oakley, Susan H; Mazloomdoost, Donna; Kleeman, Steven D; Benbouajili, Janine M; Ghodsi, Vivian; Pauls, Rachel N

    2016-01-01

    Placement of vaginal packing after pelvic reconstructive surgery is common; however, little evidence exists to support the practice. Furthermore, patients have reported discomfort from the packs. We describe pain and satisfaction in women treated with and without vaginal packing. This institutional review board-approved randomized-controlled trial enrolled patients undergoing vaginal hysterectomy with prolapse repairs. The primary outcome was visual analog scales (VASs) for pain on postoperative day 1. Allocation to "packing" ("P") or "no-packing" ("NP") arms occurred intraoperatively at the end of surgery. Visual analog scales regarding pain and satisfaction were completed early on postoperative day 1 before packing removal. Visual analog scale scores for pain, satisfaction, and bother attributable to packing were recorded before discharge. All packing and perineal pads were weighed to calculate a "postoperative vaginal blood loss." Perioperative data were collected from the hospital record. Our sample size estimation required 74 subjects. Ninety-three women were enrolled. After exclusions, 77 were randomized (P, 37; NP, 40). No differences were found in surgical information, hemoglobin levels, or narcotic use between groups. However, "postoperative vaginal blood loss" was greater in packed subjects (P discharge (P, 35.0 vs NP, 40.0; P = 0.43] were not significantly different between treatment arms. Likewise, VAS scores for satisfaction before removal of packing (P, 81.0 vs NP, 90.0; P = 0.08] and before discharge (P, 90.0 vs NP, 90.5; P = 0.60] were not significantly different. Packed patients noted lower nursing verbal pain scores (P = 0.04) and used less ketorolac (P = 0.01). Bother from packing was low overall. Although there was no difference based on VAS, women receiving vaginal packing had lower nursing documented pain and used less ketorolac than packed women. Vaginal packing may provide benefit and can remain part of the surgical practice.

  9. EFFECTS OF SLOPE SHAPES ON SOIL EROSION

    Directory of Open Access Journals (Sweden)

    Hüseyin ŞENSOY, Şahin PALTA

    2009-01-01

    Full Text Available Water is one of the most important erosive forces. A great number of factors also play a role in erosion process and slope characteristic is also one of them. The steepness and length of the slope are important factors for runoff and soil erosion. Another slope factor that has an effect on erosion is the shape of the slope. Generally, different erosion and runoff characteristics exist in different slopes which can be classified as uniform, concave, convex and complex shape. In this study, the effects of slope shape on erosion are stated and emphasized by taking similar researches into consideration.

  10. Highly Symmetric and Congruently Tiled Meshes for Shells and Domes

    Science.gov (United States)

    Rasheed, Muhibur; Bajaj, Chandrajit

    2016-01-01

    We describe the generation of all possible shell and dome shapes that can be uniquely meshed (tiled) using a single type of mesh face (tile), and following a single meshing (tiling) rule that governs the mesh (tile) arrangement with maximal vertex, edge and face symmetries. Such tiling arrangements or congruently tiled meshed shapes, are frequently found in chemical forms (fullerenes or Bucky balls, crystals, quasi-crystals, virus nano shells or capsids), and synthetic shapes (cages, sports domes, modern architectural facades). Congruently tiled meshes are both aesthetic and complete, as they support maximal mesh symmetries with minimal complexity and possess simple generation rules. Here, we generate congruent tilings and meshed shape layouts that satisfy these optimality conditions. Further, the congruent meshes are uniquely mappable to an almost regular 3D polyhedron (or its dual polyhedron) and which exhibits face-transitive (and edge-transitive) congruency with at most two types of vertices (each type transitive to the other). The family of all such congruently meshed polyhedra create a new class of meshed shapes, beyond the well-studied regular, semi-regular and quasi-regular classes, and their duals (platonic, Catalan and Johnson). While our new mesh class is infinite, we prove that there exists a unique mesh parametrization, where each member of the class can be represented by two integer lattice variables, and moreover efficiently constructable. PMID:27563368

  11. Markov Random Fields on Triangle Meshes

    DEFF Research Database (Denmark)

    Andersen, Vedrana; Aanæs, Henrik; Bærentzen, Jakob Andreas

    2010-01-01

    In this paper we propose a novel anisotropic smoothing scheme based on Markov Random Fields (MRF). Our scheme is formulated as two coupled processes. A vertex process is used to smooth the mesh by displacing the vertices according to a MRF smoothness prior, while an independent edge process label...

  12. Performance Evaluation of Coded Meshed Networks

    DEFF Research Database (Denmark)

    Krigslund, Jeppe; Hansen, Jonas; Pedersen, Morten Videbæk

    2013-01-01

    of the former to enhance the gains of the latter. We first motivate our work through measurements in WiFi mesh networks. Later, we compare state-of-the-art approaches, e.g., COPE, RLNC, to CORE. Our measurements show the higher reliability and throughput of CORE over other schemes, especially, for asymmetric...

  13. Solid Mesh Registration for Radiotherapy Treatment Planning

    DEFF Research Database (Denmark)

    Noe, Karsten Østergaard; Sørensen, Thomas Sangild

    2010-01-01

    We present an algorithm for solid organ registration of pre-segmented data represented as tetrahedral meshes. Registration of the organ surface is driven by force terms based on a distance field representation of the source and reference shapes. Registration of internal morphology is achieved usi...

  14. Quality of life in women of non-reproductive age with transvaginal mesh repair for pelvic organ prolapse: A cohort study.

    Science.gov (United States)

    Hüsch, Tanja; Mager, René; Ober, Erika; Bentler, Ralf; Ulm, Kurt; Haferkamp, Axel

    2016-09-01

    Transvaginal mesh repair has been discredited due to high complications rates in the past years. Therefore, we evaluated the quality of life (QoL) and complication rates after transvaginal mesh (TVM) repair for pelvic organ prolapse (POP). A total of 148 women who underwent TVM repair for symptomatic POP were retrospectively enrolled. Complication rates and functional outcomes were retrospectively assessed and validated, standardised questionnaires were used prospectively for evaluation of QoL. Univariate analysis by the chi(2)-test as well as a multivariate Cox regression analysis was conducted to predict mesh exposure using various variables as predictors. Intraoperative complications with bowel or bladder injury appeared in 3.4%. Mesh exposure occurred in 2.7% whereas surgical revision was necessary only in 1.4%. No predictor for mesh exposure could be identified. Postoperative complications according to Clavien-Dindo classification ≥ III occurred in only 2.8%. An improvement of POP-symptoms was reported by 84.6% according the "patients' global impression of improvement" (PGI-I) and 88.2% women would repeat the surgery. The results of the "prolapse-quality of life"-questionnaire were comparable to asymptomatic women. Only 33% reported vaginal pain with a mean vaginal pain score of 0.6 according the international index of pain. Of sexually active women, 29% reported sexual impairments and mean score of sexual impairment was 1.52. Low complication rates and a quality of life comparable to asymptomatic women following TVM repair could be achieved in our cohort. However, a high number of sexual impairments was identified although the impact of impairment was marginal. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  15. [Morphogenesis of vaginal aplasia. Therapeutic deductions].

    Science.gov (United States)

    Minh, H N; Smadja, A; Belaisch, J

    1985-01-01

    On the basis of the studies of the embryogenesis of the vagina, the authors consider that malformations classically described as being partial aplasia should not be separated from the total absence of the vagina. The important feature is the association of a functioning or non functioning uterus with the absence of the vagina. They believe that it is incorrect to describe the pouch of menstrual retention associated with a functioning uterus as "haematocolpos" and that is not justified to describe the cup-shaped vestibular depression as "hemi-vagina". According to the authors, although vaginal aplasia with a functioning uterus forming a pouch of menstrual retention constitutes an absolute indication for surgery, surgery is not justified in cases of vaginal aplasia with a non functioning uterus. If Frank's method fails in these cases, the patient or the couple should be referred to a sexologist, as women with this anomaly retain a perfect femininity, although unable to conceive.

  16. No. 148-Guidelines for Operative Vaginal Birth.

    Science.gov (United States)

    Cargill, Yvonne M; MacKinnon, Catherine Jane

    2018-02-01

    To provide guidelines for operative vaginal birth in the management of the second stage of labour. Non-operative techniques, episiotomy, and Caesarean section are compared to operative vaginal birth. Reduced fetal and maternal morbidity and mortality. MEDLINE and Cochrane databases were searched using the key words ''vacuum" and "birth" as well as "forceps" and "birth" for literature published in English from january 1970 to June 2004. The level of evidence and quality of rec-ommendations made are described using the Evaluation of Evidence from the Canadian Task Force on the Periodic Health Examination. VALIDATION: The Clinical Practice Obstetrics Committee and Executive and Council of the Society of Obstetricians and Gynaecologists of Canada approved these guidelines. Copyright © 2018. Published by Elsevier Inc.

  17. Broad Ligament Haematoma Following Normal Vaginal Delivery.

    Science.gov (United States)

    Ibrar, Faiza; Awan, Azra Saeed; Fatima, Touseef; Tabassum, Hina

    2017-01-01

    A 37-year-old, patient presented in emergency with history of normal vaginal delivery followed by development of abdominal distention, vomiting, constipation for last 3 days. She was para 4 and had normal vaginal delivery by traditional birth attendant at peripheral hospital 3 days back. Imaging study revealed a heterogeneous complex mass, ascites, pleural effusion, air fluid levels with dilatation gut loops. Based upon pelvic examination by senior gynaecologist in combination with ultrasound; a clinical diagnosis of broad ligament haematoma was made. However, vomiting and abdominal distention raised suspicion of intestinal obstruction. Due to worsening abdominal distention exploratory laparotomy was carried out. It was pseudo colonic obstruction and caecostomy was done. Timely intervention by multidisciplinary approach saved patient life with minimal morbidity.

  18. Biofilms of vaginal Lactobacillus in vitro test.

    Science.gov (United States)

    Wei, Xiao-Yu; Zhang, Rui; Xiao, Bing-Bing; Liao, Qin-Ping

    2017-01-01

    This paper focuses on biofilms of Lactobacillus spp. - a type of normal flora isolated from healthy human vaginas of women of childbearing age; thereupon, it broadens the research scope of investigation of vaginal normal flora. The static slide culture method was adopted to foster biofilms, marked by specific fluorescence staining. Laser scanning confocal and scanning electron microscopy were used to observe the microstructure of the biofilms. Photographs taken from the microstructure were analysed to calculate the density of the biofilms. The body of Lactobacillus spp., though red, turned yellow when interacting with the green extracellular polysaccharides. The structure of the biofilm and aquaporin within the biofilm were imaged. Lactobacillus density increases over time. This study provides convincing evidence that Lactobacillus can form biofilms and grow over time in vitro. This finding establishes an important and necessary condition for selecting proper strains for the pharmaceutics of vaginal ecology.

  19. Spectrum of vaginal discharge in a tertiary care setting.

    Science.gov (United States)

    Sivaranjini, R; Jaisankar, Tj; Thappa, Devinder Mohan; Kumari, Rashmi; Chandrasekhar, Laxmisha; Malathi, M; Parija, Sc; Habeebullah, S

    2013-07-01

    Vaginal discharge is one of the common reasons for gynecological consultation. Many of the causes of vaginitis have a disturbed vaginal microbial ecosystem associated with them. Effective treatment of vaginal discharge requires that the etiologic diagnosis be established and identifying the same offers a precious input to syndromic management and provides an additional strategy for human immunodeficiency virus prevention. The present study was thus carried out to determine the various causes of vaginal discharge in a tertiary care setting. A total of 400 women presenting with vaginal discharge of age between 20 and 50 years, irrespective of marital status were included in this study and women who had used antibiotics or vaginal medication in the previous 14 days and pregnant women were excluded. Of the 400 women with vaginal discharge studied, a diagnosis was established in 303 women. Infectious causes of vaginal discharge were observed in 207 (51.75%) women. Among them, bacterial vaginosis was the most common cause seen in 105 (26.25%) women. The other infections observed were candidiasis alone (61, 15.25%), trichomoniasis alone (12, 3%), mixed infections (22, 5.5%) and mucopurulent cervicitis (7 of the 130 cases looked for, 8.46%). Among the non-infectious causes, 72 (18%) women had physiological vaginal discharge and 13 (3.3%) women had cervical in situ cancers/carcinoma cervix. The pattern of infectious causes of vaginal discharge observed in our study was comparable with the other studies in India. Our study emphasizes the need for including Papanicolaou smear in the algorithm for evaluation of vaginal discharge, as it helps establish the etiology of vaginal discharge reliably and provides a valuable opportunity to screen for cervical malignancies.

  20. Effects of intrauterine contraception on the vaginal microbiota.

    Science.gov (United States)

    Bassis, Christine M; Allsworth, Jenifer E; Wahl, Heather N; Sack, Daniel E; Young, Vincent B; Bell, Jason D

    2017-09-01

    There have been conflicting reports of altered vaginal microbiota and infection susceptibility associated with contraception use. The objectives of this study were to determine if intrauterine contraception altered the vaginal microbiota and to compare the effects of a copper intrauterine device (Cu-IUD) and a levonorgestrel intrauterine system (LNG-IUS) on the vaginal microbiota. DNA was isolated from the vaginal swab samples of 76 women using Cu-IUD (n=36) or LNG-IUS (n=40) collected prior to insertion of intrauterine contraception (baseline) and at 6 months. A third swab from approximately 12 months following insertion was available for 69 (Cu-IUD, n=33; LNG-IUS, n=36) of these women. The V4 region of the bacterial 16S rRNA-encoding gene was amplified from the vaginal swab DNA and sequenced. The 16S rRNA gene sequences were processed and analyzed using the software package mothur to compare the structure and dynamics of the vaginal bacterial communities. The vaginal microbiota from individuals in this study clustered into 3 major vaginal bacterial community types: one dominated by Lactobacillus iners, one dominated by Lactobacillus crispatus and one community type that was not dominated by a single Lactobacillus species. Changes in the vaginal bacterial community composition were not associated with the use of Cu-IUD or LNG-IUS. Additionally, we did not observe a clear difference in vaginal microbiota stability with Cu-IUD versus LNG-IUS use. Although the vaginal microbiota can be highly dynamic, alterations in the community associated with the use of intrauterine contraception (Cu-IUD or LNG-IUS) were not detected over 12 months. We found no evidence that intrauterine contraception (Cu-IUD or LNG-IUS) altered the vaginal microbiota composition. Therefore, the use of intrauterine contraception is unlikely to shift the composition of the vaginal microbiota such that infection susceptibility is altered. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Vaginal Microbiota in Pregnancy: Evaluation Based on Vaginal Flora, Birth Outcome, and Race.

    Science.gov (United States)

    Subramaniam, Akila; Kumar, Ranjit; Cliver, Suzanne P; Zhi, Degui; Szychowski, Jeff M; Abramovici, Adi; Biggio, Joseph R; Lefkowitz, Elliot J; Morrow, Casey; Edwards, Rodney K

    2016-03-01

    This study aims to evaluate vaginal microbiota differences by bacterial vaginosis (BV), birth timing, and race, and to estimate parameters to power future vaginal microbiome studies. Previously, vaginal swabs were collected at 21 to 25 weeks (stored at -80°C), and vaginal smears evaluated for BV (Nugent criteria). In a blinded fashion, 40 samples were selected, creating 8 equal-sized groups stratified by race (black/white), BV (present/absent), and birth timing (preterm/term). Samples were thawed, DNA extracted, and prepared. Polymerase chain reaction (PCR) with primers targeting the 16S rDNA V4 region was used to prepare an amplicon library. PCR products were sequenced and analyzed using quantitative insight into microbial ecology; taxonomy was assigned using ribosomal database program classifier (threshold 0.8) against the modified Greengenes database. After quality control, 97,720 sequences (mean) per sample, single-end 250 base-reads, were analyzed. BV samples had greater microbiota diversity (p Microbiota did not differ by race or birth timing, but there was an association between certain microbial clusters and preterm birth (p = 0.07). To evaluate this difference, 159 patients per group are needed. There are differences in the vaginal microbiota between patients with and without BV. Larger studies should assess the relationship between microbiota composition and preterm birth. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Relationship among vaginal palpation, vaginal squeeze pressure, electromyographic and ultrasonographic variables of female pelvic floor muscles

    Directory of Open Access Journals (Sweden)

    Vanessa S. Pereira

    2014-10-01

    Full Text Available Background: The proper evaluation of the pelvic floor muscles (PFM is essential for choosing the correct treatment. Currently, there is no gold standard for the assessment of female PFM function. Objective: To determine the correlation between vaginal palpation, vaginal squeeze pressure, and electromyographic and ultrasonographic variables of the female PFM. Method: This cross-sectional study evaluated 80 women between 18 and 35 years of age who were nulliparous and had no pelvic floor dysfunction. PFM function was assessed based on digital palpation, vaginal squeeze pressure, electromyographic activity, bilateral diameter of the bulbocavernosus muscles and the amount of bladder neck movement during voluntary PFM contraction using transperineal bi-dimensional ultrasound. The Pearson correlation was used for statistical analysis (p<0.05. Results: There was a strong positive correlation between PFM function and PFM contraction pressure (0.90. In addition, there was a moderate positive correlation between these two variables and PFM electromyographic activity (0.59 and 0.63, respectively and movement of the bladder neck in relation to the pubic symphysis (0.51 and 0.60, respectively. Conclusions: This study showed that there was a correlation between vaginal palpation, vaginal squeeze pressure, and electromyographic and ultrasonographic variables of the PFM in nulliparous women. The strong correlation between digital palpation and PFM contraction pressure indicated that perineometry could easily be replaced by PFM digital palpation in the absence of equipment.

  3. Vertex Normals and Face Curvatures of Triangle Meshes

    KAUST Repository

    Sun, Xiang; Jiang, Caigui; Wallner, Johannes; Pottmann, Helmut

    2016-01-01

    This study contributes to the discrete differential geometry of triangle meshes, in combination with discrete line congruences associated with such meshes. In particular we discuss when a congruence defined by linear interpolation of vertex normals

  4. Recurrence and Pain after Mesh Repair of Inguinal Hernias

    African Journals Online (AJOL)

    Abstract. Background: Surgery for inguinal hernias has ... repair. Methods: The study was conducted on all inguinal hernia patients operated between 1st. October ... bilateral (1.6%). Only 101 .... Open Mesh Versus Laparoscopic Mesh. Repair ...

  5. Surgical Management of Pelvic floor Prolapse in women using Mesh

    African Journals Online (AJOL)

    RAH

    polytetrafluoroethylene) . This article reviews our experience with polypropylene mesh in pelvic floor repair at the. Southern General Hospital Glasgow. The objective was to determine the safety and effectiveness of the prolene mesh in the repair ...

  6. VARIABLE MESH STIFFNESS OF SPUR GEAR TEETH USING ...

    African Journals Online (AJOL)

    gear engagement. A gear mesh kinematic simulation ... model is appropnate for VMS of a spur gear tooth. The assumptions for ... This process has been continued until one complete tooth meshing cycle is ..... Element Method. Using MATLAB,.

  7. Vaginitis. Reducing the number of refractory cases.

    Science.gov (United States)

    Josey, W E

    1977-09-01

    Therapeutic failure in vaginitis can be minimized if all cases are properly diagnosed and specific therapy is given. Use of wet mounts combined with liberal use of cultures, especially for Corynebacterium vaginale, should result in an accurate diagnosis in over 90% of cases. Treatment of choice for candidiasis is nystatin or miconazole nitrate applied topically. For trichomoniasis, metronidazole should be given orally to both sexual partners. Ampicillin, cephalexin, or cephradine are recommended for C vaginale infection.

  8. Pregnancy and Vaginal Delivery after Sacrohysteropexy

    Directory of Open Access Journals (Sweden)

    Deniz Balsak

    2015-01-01

    Full Text Available Pregnancy and birth after a Pelvic Organ Prolapse (POP surgery is a rare condition and less is known about the method for delivery. A 31-year-old women with gravida 3 para 3 underwent abdominal sacrohysteropexy and transobturatuar tape (TOT procedures for stage III prolapse who delivered via vaginal birth and showed no relapse. Sacrohysteropexy is a good option for women with POP who desire fertility with a long term follow-up period.

  9. Efficacy of oral moxifloxacin for aerobic vaginitis.

    Science.gov (United States)

    Wang, C; Han, C; Geng, N; Fan, A; Wang, Y; Yue, Y; Zhang, H; Xue, F

    2016-01-01

    The purpose of this study was to investigate the therapeutic efficacy of oral moxifloxacin for aerobic vaginitis (AV). We also identified factors that are associated with therapeutic efficacy. This prospective study enrolled general gynecological outpatients at Tianjin Medical University General Hospital between September 2012 and May 2014. Women diagnosed with AV (n = 102) were recruited. All enrolled women were treated with oral moxifloxacin, 400 mg once daily for 6 days (one course). Therapeutic efficacy was evaluated based on microscopic criteria, and cure rates were calculated. Women who were microscopically improved (but not cured) received a second course of therapy. Women classified with microscopic failure were treated using other strategies. Univariate and multivariate logistic regression analysis was used to identify factors that may be associated with a cure after one course of therapy. After one course of therapy, 65.7 % (67/102) of women were cured, 29.4 % (30/102) of women were improved (but not cured), 4.9 % (5/102) of women failed to respond to the therapy. After two courses of therapy, 85.3 % (87/102) of women were cured, 9.8 % (10/102) of women were improved, 4.9 % (5/102) of women failed to respond to the therapy, and clinical improvement was achieved in additional women. In the multivariate logistic regression analysis, women with a baseline vaginal pH value of vaginal pH value of ≥5.0 (OR, 3.503; 95 % CI, 1.278-9.601). Moxifloxacin is an effective therapeutic option for patients with AV. Most women with AV were cured with one course of moxifloxacin. For those with a higher vaginal pH value of ≥5.0 before treatment, two courses of therapy should be considered.

  10. [Saforelle - a new approach to treat vaginitis].

    Science.gov (United States)

    Karamisheva, V; Nachev, A

    2015-01-01

    Infections of the vulva and vagina are one of the most common gynecological diseases. They can be determined by a variety of physical, chemical and biological factors. The main risk factors contributing to vaginitis are aerobic and anaerobic bacterias, fungal and viral infections, and irritants. Subjective complaints are pruritus, vulvar and/or perivulvar erytema and different in volume and characterization discharge. Excepting etiological treatment in most cases it is necessary to use additional agents, for example Saforelle.

  11. Necrotising fasciitis after hysterectomy and concomitant transvaginal mesh repair in a patient with pelvic organ prolapse.

    Science.gov (United States)

    Pushkar, Dmitry Y; Vasilchenko, Mikhail I; Kasyan, George R

    2013-10-01

    Necrotising fasciitis is a severe form of soft tissue infection. Herein, we present an unreported complication of the transvaginal repair of a pelvic organ prolapse (POP) with trocar-guided polypropylene mesh and a concomitant hysterectomy. A 61-year-old Caucasian female who had been using an intrauterine device (IUD) for 30 years presented with a stage 3 pelvic organ prolapse. A genital ultrasound examination confirmed the presence of an IUD, but found no endometrial abnormalities. The surgical management was limited to a transvaginal hysterectomy and simultaneous anterior vaginal wall repair augmented with trocar-guided mesh. A morphological examination of the removed uterus confirmed the presence of the intrauterine device and additionally found endometrial cancer (T1N0M0), which was not revealed during the preoperative ultrasound. Within 6 days of the surgery, she developed anaerobic bilateral necrotising fasciitis on both thighs. Non-clostridial streptococci were identified in the wound. After 18 days of intensive care, the patient died of fatal coagulopathy.

  12. The use of porcine small intestinal submucosa mesh (SURGISIS as a pelvic sling in a man and a woman with previous pelvic surgery: two case reports

    Directory of Open Access Journals (Sweden)

    Al-Sahaf Osama

    2009-02-01

    Full Text Available Abstract Introduction Closing the pelvic peritoneum to prevent the small bowel dropping into the pelvis after surgery for locally recurrent rectal cancer is important to prevent adhesions deep in the pelvis or complications of adjuvant radiotherapy. Achieving this could be difficult because sufficient native tissue is unavailable; we report on the use of small intestine submucosa extra-cellular matrix mesh in the obliteration of the pelvic brim. Case presentation We describe two cases in which submucosa extra-cellular matrix mesh was used to obliterate the pelvic brim following resection of a recurrent rectal tumour; the first patient, a 78-year-old Caucasian man, presented with small bowel obstruction caused by adhesions to a recurrent rectal tumour. The second patient, an 84-year-old Caucasian woman, presented with vaginal discharge caused by an entero-vaginal fistula due to a recurrent rectal tumour. Conclusion We report on the use of submucosa extra-cellular matrix mesh as a pelvic sling in cases where primary closure of the pelvic peritoneum is unfeasible. Its use had no infective complications and added minimal morbidity to the postoperative period. This is an original case report that would be of interest to general and colorectal surgeons.

  13. Vaginal rupture and evisceration in a dog.

    Science.gov (United States)

    Prassinos, Nikitas N; Adamama-Moraitou, Katerina K; Ververidis, Haralabos N; Anagnostou, Tilemachos L; Kladakis, Stefanos E

    2010-09-01

    A 1.5-year-old German Shepherd mixed breed dog was admitted with mild haemorrhage from the vulva and a perineal mass of 24-hour duration, which had been first observed immediately after parturition. Parturition had occurred at low ambient temperature, and only one puppy survived out of the seven oversized fetuses. The dog was in poor body condition, dehydrated, hypothermic, depressed, non-ambulatory and in a state of shock. Intestinal loops, the urinary bladder and the uterine horns and body were protruding from the vulva. A true vaginal prolapse was also observed. The abdominal viscera were flushed with warm sterile saline solution, protected and maintained wet. The laboratory findings included moderate anaemia, leukocytosis, hypoalbuminaemia, azotaemia and elevated liver enzyme activities. Stabilisation of the dog's general condition was attempted before surgery. Antimicrobial and analgesic drugs were also administered. After exploratory laparotomy the protruding organs, which were in good condition, were reduced. A recent rupture in the vaginal wall, approximately 6 cm long, was observed. Ovariohysterectomy and partial vaginectomy were performed. The preoperative course of therapy was continued, but the bitch died 12 hours later. The probable cause of vaginal rupture and evisceration in this bitch was tenesmus and/or trauma due to the oversized fetuses.

  14. Vernix caseosa peritonitis after vaginal delivery.

    Science.gov (United States)

    Sadath, Shameema A; Abo Diba, Fathiya I; Nayak, Surendra; Shamali, Iman Al; Diejomaoh, Michael F

    2013-01-01

    Vernix caseosa peritonitis (VCP) is a very unusual complication caused by inflammatory response to amniotic fluid spilled into the maternal peritoneal cavity. Twenty-seven cases have been reported, and all occurred after cesarean section. We present a case of VCP following vaginal delivery; this may be the first case reported after vaginal delivery. Mrs. A, 28 years old, gravida 3, para 2, with one previous cesarean section, was admitted at 41 weeks gestation in active labor. Vacuum extraction was performed to deliver a healthy male baby, 4.410 kg, Apgar scores 7, 8. She developed fever, acute abdominal pain, and distension about 3 hours after delivery. A diagnosis of acute abdomen was made. Laparotomy was performed and it revealed neither uterine scar rupture nor other surgical emergencies, but 500 mL of turbid fluid and some cheesy material on the serosal surface of all viscera. Biopsies were taken. She had a course of antibiotics and her recovery was complete. Histology of the peritoneal fluid and tissue biopsy resulted in a diagnosis of VCP. Clinical diagnosis of peritonitis due to vernix caseosa should be considered in patients presenting postpartum with an acute abdomen after vaginal delivery.

  15. Vaginal agenesis: Experience with sigmoid colon neovaginoplasty

    Directory of Open Access Journals (Sweden)

    Rawat Jiledar

    2010-01-01

    Full Text Available Aim: Objective of this study is to report our experience with sigmoid vaginoplasty in adolescents. Materials and Methods: A retrospective study of children with vaginal atresia and Mayer-Rokitansky-Kuster-Hauser syndrome. The sigmoid segment was used for vaginoplasty in all the cases. Results: Eight children were studied over a period of 7 years. The postoperative complications were ileus in 2, mucosal prolapse of the neovagina in 1, and minor wound infection in 1 patient. Seven patients are on regular follow-up. All the neovaginas were patent and functional. One patient had unacceptable perineal appearance, that is, badly scarred perineum as a late complication. None of the patients had vaginal stenosis or excessive mucus discharge, during follow-up visits. Out of the 7 patients, 2 patients are sexually active and satisfied. Conclusions: Sigmoid vaginoplasty is a safe and acceptable procedure for vaginal agenesis with good cosmetic results and acceptable complications rate. Sigmoid colon vaginoplasty is the treatment of choice because of its large lumen, thick walls resistant to trauma, adequate secretion allowing lubrication, not necessitating prolonged dilatation, and short recovery time.

  16. Transvaginal six-arm mesh OPUR in women with apical pelvic organ prolapse - analysis of short-term results, pelvic floor ultrasound evaluation.

    Science.gov (United States)

    Kluz, Tomasz; Wlaźlak, Edyta; Surkont, Grzegorz

    2017-01-01

    Analysis of feasibility, efficacy and short-term results after six-arm transvaginal mesh OPUR implantation in women with apical prolapse. The same surgeon operated all of 39 women using mesh OPUR. Preoperatively patients had a standardized interview and clinical examination. Intraoperative and postoperative complications were analyzed. Postoperative evaluation included standardized interview, clinical examination and standardized pelvic floor ultrasound performed with 2D transvaginal probe and 4D abdominal probe. There was no complication that needed operative intervention. Hematomas in 3 patients resolved spontaneously. Transient voiding difficulties which lasted less than 7 days were observed in 5 patients. No erosion was observed. Comparison of pre- and postoperative results in 34 women revealed that in all 3 compartments improvement in POP-Q scale was statistically significant (p mesh needed re-operation. During PFS-TV in 94.1% of patients urethra was normobile or hypermobile. In all of the patients urethral end of the mesh was positioned far enough from the middle part of the urethra (ultrasound) to implant suburethral sling without risk of collision. Sexually active women did not inform of any important discomfort or pain during intercourse. It seems that six-arm OPUR mesh, if implanted under strict surgical rules, gives low risk of complications and high chance to successfully reduce POP symptoms in short term after the operation. It seems that OPUR mesh should not have negative influence on the results after anti-incontinence suburethral sling.

  17. Elevated temperature erosive wear of metallic materials

    International Nuclear Information System (INIS)

    Roy, Manish

    2006-01-01

    Solid particle erosion of metals and alloys at elevated temperature is governed by the nature of the interaction between erosion and oxidation, which, in turn, is determined by the thickness, pliability, morphology, adhesion characteristics and toughness of the oxide scale. The main objective of this paper is to critically review the present state of understanding of the elevated temperature erosion behaviour of metals and alloys. First of all, the erosion testing at elevated temperature is reviewed. This is followed by discussion of the essential features of elevated temperature erosion with special emphasis on microscopic observation, giving details of the erosion-oxidation (E-O) interaction mechanisms. The E-O interaction has been elaborated in the subsequent section. The E-O interaction includes E-O maps, analysis of transition criteria from one erosion mechanism to another mechanism and quantification of enhanced oxidation kinetics during erosion. Finally, the relevant areas for future studies are indicated. (topical review)

  18. Understanding Soil Erosion in Irrigated Agriculture

    OpenAIRE

    O' Schwankl, Lawrence J

    2006-01-01

    A soil's physical and chemical properties determine whether it is vulnerable to erosion, which can reduce soil quality and cause other problems besides. Learn the basics of identifying what type of erosion is affecting your land and what's causing it.

  19. On Reducing Delay in Mesh-Based P2P Streaming: A Mesh-Push Approach

    Science.gov (United States)

    Liu, Zheng; Xue, Kaiping; Hong, Peilin

    The peer-assisted streaming paradigm has been widely employed to distribute live video data on the internet recently. In general, the mesh-based pull approach is more robust and efficient than the tree-based push approach. However, pull protocol brings about longer streaming delay, which is caused by the handshaking process of advertising buffer map message, sending request message and scheduling of the data block. In this paper, we propose a new approach, mesh-push, to address this issue. Different from the traditional pull approach, mesh-push implements block scheduling algorithm at sender side, where the block transmission is initiated by the sender rather than by the receiver. We first formulate the optimal upload bandwidth utilization problem, then present the mesh-push approach, in which a token protocol is designed to avoid block redundancy; a min-cost flow model is employed to derive the optimal scheduling for the push peer; and a push peer selection algorithm is introduced to reduce control overhead. Finally, we evaluate mesh-push through simulation, the results of which show mesh-push outperforms the pull scheduling in streaming delay, and achieves comparable delivery ratio at the same time.

  20. Effect of Vaginal or Systemic Estrogen on Dynamics of Collagen Assembly in the Rat Vaginal Wall1

    Science.gov (United States)

    Montoya, T. Ignacio; Maldonado, P. Antonio; Acevedo, Jesus F.; Word, R. Ann

    2014-01-01

    ABSTRACT The objective of this study was to compare the effects of systemic and local estrogen treatment on collagen assembly and biomechanical properties of the vaginal wall. Ovariectomized nulliparous rats were treated with estradiol or conjugated equine estrogens (CEEs) either systemically, vaginal CEE, or vaginal placebo cream for 4 wk. Low-dose local CEE treatment resulted in increased vaginal epithelial thickness and significant vaginal growth without uterine hyperplasia. Furthermore, vaginal wall distensibility increased without compromise of maximal force at failure. Systemic estradiol resulted in modest increases in collagen type I with no change in collagen type III mRNA. Low-dose vaginal treatment, however, resulted in dramatic increases in both collagen subtypes whereas moderate and high dose local therapies were less effective. Consistent with the mRNA results, low-dose vaginal estrogen resulted in increased total and cross-linked collagen content. The inverse relationship between vaginal dose and collagen expression may be explained in part by progressive downregulation of estrogen receptor-alpha mRNA with increasing estrogen dose. We conclude that, in this menopausal rat model, local estrogen treatment increased total and cross-linked collagen content and markedly stimulated collagen mRNA expression in an inverse dose-effect relationship. High-dose vaginal estrogen resulted in downregulation of estrogen receptor-alpha and loss of estrogen-induced increases in vaginal collagen. These results may have important clinical implications regarding the use of local vaginal estrogen therapy and its role as an adjunctive treatment in women with loss of vaginal support. PMID:25537371