  1. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting

    OpenAIRE

    Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas

    2007-01-01

    Background: Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. Methods: A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated ...

  2. The role of uncentrifuged urine microscopy in the diagnosis of ...

    African Journals Online (AJOL)

    Background: Urinary tract infection (UTI) is one of the most common nosocomial bacterial infections prevalent in both males and females. UTI is diagnosed on the basis of clinical symptoms, microscopy and culture of urine. This study was done to establish the role of the routine uncentrifuged urine microscopy using culture ...

  3. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

    Science.gov (United States)

    Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas

    2007-01-01

    Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.

  4. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  5. Nonhazardous Urine Pretreatment Method for Future Exploration Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A nonhazardous urine pretreatment system prototype is proposed that will stabilize urine against biological growth or chemical instabilities without using hazardous...

  6. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  7. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  8. Urine pretreatment for waste water processing systems. [for space station

    Science.gov (United States)

    Winkler, H. E.; Verostko, C. E.; Dehner, G. F.

    1983-01-01

    Recovery of high quality water from urine is an essential part of life support on a Space Station to avoid costly launch and resupply penalties. Water can be effectively recovered from urine by distillation following pretreatment by a chemical agent to inhibit microorganism contamination and fix volatile ammonia constituents. This paper presents the results of laboratory investigations of several pretreatment chemicals which were tested at several concentration levels in combination with sulfuric acid in urine. The optimum pretreatment formulation was then evaluated with urine in the Hamilton Standard Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES). Over 2600 hours of test time was accumulated. Results of these laboratory and system tests are presented in this paper.

  9. Nonhazardous Urine Pretreatment Method for Future Exploration Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A novel urine pretreatment that will prevent biological growth or chemical instabilities in urine without using hazardous chemicals is proposed. Untreated urine...

  10. Predicting Neisseria gonorrhoeae and Chlamydia trachomatis infection using risk scores, physical examination, microscopy, and leukocyte esterase urine dipsticks among asymptomatic women attending a family planning clinic in Kenya.

    Science.gov (United States)

    Tyndall, M W; Kidula, N; Sande, J; Ombette, J; Temmerman, M

    1999-09-01

    Sexually transmitted infections (STIs) continue to exert a tremendous health burden on women in developing countries. Poor socioeconomic status, inadequate knowledge, lack of diagnostic facilities, and shortages of effective treatment all contribute to the high incidence of STIs. The use of clinical algorithms for the detection and management of STIs has gained widespread acceptance in settings where there are limited resources. Evaluation of these algorithms have been few, especially in women who are not recognized as members of high-risk groups. To develop a simple scoring system based on historical and demographic data, physical findings, microscopy, and leukocyte esterase (LE) urine dipsticks to predict cervical gonococcal and chlamydial infection among asymptomatic women. One thousand and forty-eight women attending an urban family planning clinic in Nairobi were randomly selected to participate. After the identification of factors that were associated with infection, we assigned one point each for: age 25 or younger, single status, two or more sex partners in the past year, cervical discharge, cervical swab leukocytes, and a positive LE urine dipstick. Identification of any one of these six factors gave a sensitivity of 85% and a specificity of 30% for the detection of cervical infections. A positive LE urine dipstick had a sensitivity of 63 % and a specificity of 47% when used alone and did not contribute to the identification of infection if a physical examination was performed. The application of existing clinical algorithms to this population performed poorly. The use of risk scores, physical examination, microscopy, and the urine LE dipstick, used alone or in combination, as predictors of gonococcal or chlamydial cervical infection was of limited utility in low-risk, asymptomatic women. Accurate diagnostic testing is necessary to optimize treatment.

  11. Diagnostic performance of urine dipstick testing in children with suspected UTI: a systematic review of relationship with age and comparison with microscopy.

    Science.gov (United States)

    Mori, R; Yonemoto, N; Fitzgerald, A; Tullus, K; Verrier-Jones, K; Lakhanpaul, M

    2010-04-01

    Prompt diagnosis of urinary tract infection (UTI) in children is needed to initiate treatment but is difficult to establish without urine testing, and reliance on culture leads to delay. Urine dipsticks are often used as an alternative to microscopy, although the diagnostic performance of dipsticks at different ages has not been established systematically. Studies comparing urine dipstick testing in infants versus older children and urine dipstick versus microscopy were systematically searched and reviewed. Meta-analysis of available studies was conducted. Six studies addressed these questions. The results of meta-analysis showed that the performance of urine dipstick testing was significantly less in the younger children when compared with older children (p UTI in children over 2 years than for younger children.

  12. Morphological evidence by scanning electron microscopy of excretion of metacyclic forms of Trypanosoma cruzi in vector's urine

    Directory of Open Access Journals (Sweden)

    Rodrigo Zeledon

    1988-09-01

    Full Text Available Comparision by scanning electron microscopy (SEM of Trypanosoma cruzi flagellates attached to the cuticle of the rectal gland of infected Dipetalogaster maxima nymphs, showed marked differences before amd after feeding. Before feeding numerous metacyclic trypomastigotes were observed among the abundant epimastigotes that formed the carpet of flagellates. On the other hand, in insects that were allowed to urinate for 24 hours after a meal, the metacyclics were scarce,indicating that they had been detached by the urine flow. An asymetric type of cell division, probably originating both an epi-and a trypomastigote, was occasionally observed. The occurrence of swellings at different levels of the flagella of epimastigotes suggests that secondary sites of attachment may be common.Observando-se, em microscopia eletrônica de varedura, formas flageladas do Trypanosoma cruzi presas a cutícula da glândula retal de ninfas infectadas de Dipetalogaster maxima verificaram-se nítidas diferenças antes e depois da alimentação. Antes, viam-se numerosos tripomastigotas metacíclicos entre os abundantes epimastigotas que formavam o tapete de flagelados, ao passo que nos insetos que urinavam dentro das 24 horas após o repasto os metacíclicos eram raros, indicando que haviam sido desprendidos pelo fluxo urinário. Foi notado, as vezes, um tipo assimétrico de divisão celular, originando um epi e um tripomastigota. Nos flagelados dos epimastigotas a presença de dilatações a diferentes níveis sugere que lugares secundários de aderência podem ser comuns.

  13. 21 CFR 876.1800 - Urine flow or volume measuring system.

    Science.gov (United States)

    2010-04-01

    ... volume measuring system. (a) Identification. A urine flow or volume measuring system is a device that measures directly or indirectly the volume or flow of urine from a patient, either during the course of... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Urine flow or volume measuring system. 876.1800...

  14. Simple questionnaire and urine reagent strips compared to microscopy for the diagnosis of Schistosoma haematobium in a community in northern Ghana.

    Science.gov (United States)

    Bogoch, Isaac I; Andrews, Jason R; Dadzie Ephraim, Richard K; Utzinger, Jürg

    2012-10-01

    To evaluate the utility of a simple questionnaire and urine reagent strip testing for the rapid diagnosis of Schistosoma haematobium in rural northern Ghana. Cross-sectional parasitological and questionnaire survey in a community in northern Ghana. Participants provided two urine specimens that were examined under a microscope using a centrifugation method. The first urine sample was additionally subjected to reagent strip testing. A short questionnaire was administered to all participants. Microscopy of urine samples obtained from 208 individuals aged 1-77 years revealed an S. haematobium prevalence of 6.8%. The presence of any blood or protein on a urine reagent strip was 100% and 42% sensitive, and 93% and 80% specific for S. haematobium diagnosis. Questionnaires were completed by 198 individuals. Self-reported haematuria showed a sensitivity of 53% and a specificity of 85%. A dichotomous two-question panel was helpful in S. haematobium diagnosis, with working and playing near the river significantly associated with S. haematobium infection (P < 0.001). The use of urine reagent strips, coupled with questions pertaining to water contact patterns, might be considered for point-of-contact diagnosis of S. haematobium where microscopy is unavailable. © 2012 Blackwell Publishing Ltd.

  15. Atomic force microscopy of starch systems.

    Science.gov (United States)

    Zhu, Fan

    2017-09-22

    Atomic force microscopy (AFM) generates information on topography, adhesion, and elasticity of sample surface by touching with a tip. Under suitable experimental settings, AFM can image biopolymers of few nanometers. Starch is a major food and industrial component. AFM has been used to probe the morphology, properties, modifications, and interactions of starches from diverse botanical origins at both micro- and nano-structural levels. The structural information obtained by AFM supports the blocklet structure of the granules, and provides qualitative and quantitative basis for some physicochemical properties of diverse starch systems. It becomes evident that AFM can complement other microscopic techniques to provide novel structural insights for starch systems.

  16. Correlation between dipstick urinalysis and urine sediment microscopy in detecting haematuria among children with sickle cell anaemia in steady state in Ilorin, Nigeria.

    Science.gov (United States)

    Anigilaje, Emmanuel Ademola; Adedoyin, Olanrewaju Timothy

    2013-01-01

    Haematuria is one of the clinical manifestations of sickle cell nephropathy. Although dipstick urinalysis detects haemoglobin and by extension haematuria; it does not confirm haematuria. Urine sediment microscopy confirms haematuria and constitutes a non-invasive "renal biopsy". The need to correlate dipstick urinalysis and urine sediment microscopy findings becomes important because of the cheapness, quickness and simplicity of the former procedure. Dipstick urinalysis and urine sediment microscopy were carried (both on first contact and a month after) among consecutive steady state sickle cell anaemia children attending sickle cell clinic at the University of Ilorin Teaching Hospital between October 2004 and July 2005. A total of 75 sickle cell anemia children aged between 1-17 years met the inclusion criteria. Haematuria was found in 12 children (16.0%) and persistent haematuria in 10 children 13.3%. Age and gender did not have significant relationship with haematuria both at first contact (p values 0.087 and 0.654 respectively) and at follow-up (p values 0.075 and 0.630 respectively). Eumorphic haematuria was confirmed in all the children with persistent haematuria with Pearson correlation +0.623 and significant p value of 0.000. The study has revealed a direct significant correlation for haematuria detected on dipstick urinalysis and at urine sediment microscopy. It may therefore be inferred that dipstick urinalysis is an easy and readily available tool for the screening of haematuria among children with sickle cell anaemia and should therefore be done routinely at the sickle cell clinics.

  17. System analysis of force feedback microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Mario S. [CFMC/Dep. de Física, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Costa, Luca [European Synchrotron Radiation Facility, 6 rue Jules Horowitz BP 220, 38043 Grenoble Cedex (France); Université Joseph Fourier BP 53, 38041 Grenoble Cedex 9 (France); Chevrier, Joël [European Synchrotron Radiation Facility, 6 rue Jules Horowitz BP 220, 38043 Grenoble Cedex (France); Université Grenoble Alpes, Inst NEEL, F-38042 Grenoble (France); CNRS, Inst NEEL, F-38042 Grenoble (France); Comin, Fabio [European Synchrotron Radiation Facility, 6 rue Jules Horowitz BP 220, 38043 Grenoble Cedex (France)

    2014-02-07

    It was shown recently that the Force Feedback Microscope (FFM) can avoid the jump-to-contact in Atomic force Microscopy even when the cantilevers used are very soft, thus increasing force resolution. In this letter, we explore theoretical aspects of the associated real time control of the tip position. We take into account lever parameters such as the lever characteristics in its environment, spring constant, mass, dissipation coefficient, and the operating conditions such as controller gains and interaction force. We show how the controller parameters are determined so that the FFM functions at its best and estimate the bandwidth of the system under these conditions.

  18. System analysis of force feedback microscopy

    International Nuclear Information System (INIS)

    Rodrigues, Mario S.; Costa, Luca; Chevrier, Joël; Comin, Fabio

    2014-01-01

    It was shown recently that the Force Feedback Microscope (FFM) can avoid the jump-to-contact in Atomic force Microscopy even when the cantilevers used are very soft, thus increasing force resolution. In this letter, we explore theoretical aspects of the associated real time control of the tip position. We take into account lever parameters such as the lever characteristics in its environment, spring constant, mass, dissipation coefficient, and the operating conditions such as controller gains and interaction force. We show how the controller parameters are determined so that the FFM functions at its best and estimate the bandwidth of the system under these conditions

  19. Quantification of Urine Elimination Behaviors in Cats with a Video Recording System

    OpenAIRE

    R. Dulaney, D.; Hopfensperger, M.; Malinowski, R.; Hauptman, J.; Kruger, J.M.

    2017-01-01

    Background Urinary disorders in cats often require subjective caregiver quantification of clinical signs to establish a diagnosis and monitor therapeutic outcomes. Objective To investigate use of a video recording system (VRS) to better assess and quantify urination behaviors in cats. Animals Eleven healthy cats and 8 cats with disorders potentially associated with abnormal urination patterns. Methods Prospective study design. Litter box urination behaviors were quantified with a VRS for 14 d...

  20. Microbial ureolysis in the seawater-catalysed urine phosphorus recovery system: Kinetic study and reactor verification.

    Science.gov (United States)

    Tang, Wen-Tao; Dai, Ji; Liu, Rulong; Chen, Guang-Hao

    2015-12-15

    Our previous study has confirmed the feasibility of using seawater as an economical precipitant for urine phosphorus (P) precipitation. However, we still understand very little about the ureolysis in the Seawater-based Urine Phosphorus Recovery (SUPR) system despite its being a crucial step for urine P recovery. In this study, batch experiments were conducted to investigate the kinetics of microbial ureolysis in the seawater-urine system. Indigenous bacteria from urine and seawater exhibited relatively low ureolytic activity, but they adapted quickly to the urine-seawater mixture during batch cultivation. During cultivation, both the abundance and specific ureolysis rate of the indigenous bacteria were greatly enhanced as confirmed by a biomass-dependent Michaelis-Menten model. The period for fully ureolysis was decreased from 180 h to 2.5 h after four cycles of cultivation. Based on the successful cultivation, a lab-scale SUPR reactor was set up to verify the fast ureolysis and efficient P recovery in the SUPR system. Nearly complete urine P removal was achieved in the reactor in 6 h without adding any chemicals. Terminal Restriction Fragment Length Polymorphism (TRFLP) analysis revealed that the predominant groups of bacteria in the SUPR reactor likely originated from seawater rather than urine. Moreover, batch tests confirmed the high ureolysis rates and high phosphorus removal efficiency induced by cultivated bacteria in the SUPR reactor under seawater-to-urine mixing ratios ranging from 1:1 to 9:1. This study has proved that the enrichment of indigenous bacteria in the SUPR system can lead to sufficient ureolytic activity for phosphate precipitation, thus providing an efficient and economical method for urine P recovery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Microscopy

    Science.gov (United States)

    Patricia A. Moss; Les Groom

    2001-01-01

    Microscopy is the study and interpretation of images produced by a microscope. "Interpretation" is the keyword, because the microscope enables one to see structures that are too small or too close together to be resolved by the unaided eye. (The human eye cannot separate two points or lines that are closer together than 0.1 mm.) it is important to...

  2. The further development of the active urine collection device: a novel continence management system.

    Science.gov (United States)

    Tinnion, E; Jowitt, F; Clarke-O'Neill, S; Cottenden, A M; Fader, M; Sutherland, I

    2003-01-01

    Continence difficulties affect the lives of a substantial minority of the population. Women are far more likely than men to be affected by urinary incontinence but the range of management options for them is limited. There has been considerable interest in developing an external urine collection system for women but without success to date. This paper describes the development and preliminary clinical testing of an active urine collection device (AUCD), which could provide a solution for sufferers. The device uses stored vacuum, protected by a high bubble point filter, to remove urine as quickly as it is produced. This allows a small battery-operated pump to provide the required vacuum, enabling the device to be portable. Two different types of non-invasive patient/device interface were developed, and tested by volunteers: urinal and small pad. The slimline urinal was popular with users although liquid noise was a problem. The pad interface was successful on occasions but further work is necessary to produce a reliable pad. This study has successfully demonstrated that a prototype AUCD liquid handling system can remove urine at clinically relevant flowrates. While further development is required, volunteer tests have shown that the AUCD could be a useful advance in continence management.

  3. Visualization and natural control systems for microscopy

    DEFF Research Database (Denmark)

    Taylor, Russell M.; Borland, David; Brooks, Frederick P.

    2005-01-01

    This chapter presents these microscope systems, along with brief descriptions of the science experiments driving the development of each system. Beginning with a discussion of the philosophy that has driven the Nanoscale Science Research Group (NSRG) and the methods used, the chapter describes th...

  4. Bilirubin - urine

    Science.gov (United States)

    Conjugated bilirubin - urine; Direct bilirubin - urine ... Bilirubin is not normally found in the urine. ... Increased levels of bilirubin in the urine may be due to: Biliary tract disease Cirrhosis Gallstones in the biliary tract Hepatitis Liver disease ...

  5. Application of duckweed for human urine treatment in Bioregenerative Life Support System

    Science.gov (United States)

    Manukovsky, Nickolay; Kovalev, Vladimir

    The object of the study was the common duckweed Lemna minor L. Thanks to the ability to assimilate mineral and organic substances, duckweed is used to purify water in sewage lagoons. In addition, duckweed biomass is known to be a potential high-protein feed resource for domestic animals and fish. The aim of the study was to estimate an application of duckweed in a two-stage treatment of human urine in Bioregenerative Life Support System (BLSS). At the first stage, the urine’s organic matter is oxidized by hydrogen peroxide. Diluted solution of oxidized urine is used for cultivation of duckweed. The appointment of duckweed is the assimilation of mineralized substances of urine. Part of the duckweed biomass yield directly or after composting could be embedded in the soil-like substrate as organic fertilizer to compensate the carry-over in consequence of plant growing. The rest duckweed biomass could be used as a feed for animals in BLSS. Then, the residual culture liquid is concentrated and used as a source of dietary salt. It takes 10-15 m2 of duckweed culture per crewmember to treat oxidized urine. The BLSS configuration including two-component subsystem of urine treatment is presented.

  6. Urine transduction to usable energy: A modular MFC approach for smartphone and remote system charging

    OpenAIRE

    Walter, X. A.; Stinchcombe, A.; Greenman, J.; Ieropoulos, I.

    2017-01-01

    This study reports for the first time the full charging of a state-of-the-art mobile smartphone, using Microbial Fuel Cells fed with urine. This was possible by employing a new design of MFC that allowed scaling-up without power density losses. Although it was demonstrated in the past that a basic mobile phone could be charged by MFCs, the present study goes beyond this to show how, simply using urine, charges a modern-day smartphone. Several energy-harvesting systems have been tested and res...

  7. Performance evaluation of automated urine microscopy as a rapid, non-invasive approach for the diagnosis of non-gonococcal urethritis

    Science.gov (United States)

    Pond, Marcus J; Nori, Achyuta V; Patel, Sheel; Laing, Ken; Ajayi, Margarita; Copas, Andrew J; Butcher, Philip D; Hay, Phillip; Sadiq, Syed Tariq

    2015-01-01

    Objectives Gram-stained urethral smear (GSUS), the standard point-of-care test for non-gonococcal urethritis (NGU) is operator dependent and poorly specific. The performance of rapid automated urine flow cytometry (AUFC) of first void urine (FVU) white cell counts (UWCC) for predicting Mycoplasma genitalium and Chlamydia trachomatis urethral infections was assessed and its application to asymptomatic infection was evaluated. Methods Receiver operating characteristic curve analysis, determining FVU-UWCC threshold for predicting M. genitalium or C. trachomatis infection was performed on 208 ‘training’ samples from symptomatic patients and subsequently validated using 228 additional FVUs obtained from prospective unselected patients. Results An optimal diagnostic threshold of >29 UWC/µL gave sensitivities and specificities for either infection of 81.5% (95% CI 65.1% to 91.6%) and 85.8% (79.5% to 90.4%), respectively, compared with 86.8% (71.1% to 95%) and 64.7% (56.9% to 71.7%), respectively, for GSUS, using the training set samples. FVU-UWCC demonstrated sensitivities and specificities of 69.2% (95% CI 48.1% to 84.9%) and 92% (87.2% to 95.2%), respectively, when using validation samples. In asymptomatic patients where GSUS was not used, AUFC would have enabled more infections to be detected compared with clinical considerations only (71.4% vs 28.6%; p=0.03). The correlation between UWCC and bacterial load was stronger for M. genitalium compared with C. trachomatis (τ=0.426, p≤0.001 vs τ=0.295, p=0.022, respectively). Conclusions AUFC offers improved specificity over microscopy for predicting C. trachomatis or M. genitalium infection. Universal AUFC may enable non-invasive diagnosis of asymptomatic NGU at the PoC. The degree of urethral inflammation exhibits a stronger association with pathogen load for M. genitalium compared with C. trachomatis. PMID:25614466

  8. Urine drug screen

    Science.gov (United States)

    Drug screen - urine ... detect the presence of illegal and some prescription drugs in your urine. Their presence may indicate that you recently used these drugs. Some drugs may remain in your system for ...

  9. The culture of Chlorella vulgaris with human urine in multibiological life support system experiments

    Science.gov (United States)

    Li, Ming; Liu, Hong; Tong, Ling; Fu, Yuming; He, Wenting; Hu, Enzhu; Hu, Dawei

    The Integrative Experimental System (IES) was established as a tool to evaluate the rela-tionship of the subsystems in Bioregenerative Life Support System, and Multibiological Life Support System Experiments (MLSSE) have been conducted in the IES. The IES consists of a higher plant chamber, an animal chamber and a plate photo bioreactor (PPB) which cultivated lettuce (Lactuca sativa L.), silkworm (Bombyx Mori L.) and microalgae (Chlorella vulgaris), respectively. In MLSSE, four volunteers took turns breathing the system air through a tube connected with the animal chamber periodically. According to the CO2 concentration in the IES, the automotive control system of the PPB changed the light intensity regulating the photosynthesis of Chlorella vulgaris to make CO2 /O2 in the system maintain at stable levels. Chlorella vulgaris grew with human urine by carrying certain amount of alga liquid out of the bioreactor every day with synthetic urine replenished into the system, and O2 was regenerated, at the same time human urine was purified. Results showed that this IES worked stably and Chlorella vulgaris grew well; The culture of Chlorella vulgaris could be used to keep the balance of CO2 and O2 , and the change of light intensity could control the gas composition in the IES; Microalgae culture could be used in emergency in the system, the culture of Chlorella vulgaris could recover to original state in 5 days; 15.6 ml of condensation water was obtained every day by the culture of Chlorella vulgaris; The removal efficiencies of N, P in human urine could reach to 98.2% and 99.5%.

  10. Ultra-compact silicon nitride grating coupler for microscopy systems

    OpenAIRE

    Zhu, Yunpeng; Wang, Jie; Xie, Weiqiang; Tian, Bin; Li, Yanlu; Brainis, Edouard; Jiao, Yuqing; Van Thourhout, Dries

    2017-01-01

    Grating couplers have been widely used for coupling light between photonic chips and optical fibers. For various quantum-optics and bio-optics experiments, on the other hand, there is a need to achieve good light coupling between photonic chips and microscopy systems. Here, we propose an ultra-compact silicon nitride (SiN) grating coupler optimized for coupling light from a waveguide to a microscopy system. The grating coupler is about 4 by 2 mu m(2) in size and a 116 nm 1 dB bandwidth can be...

  11. Modeling, design and analysis of a stand-alone hybrid power generation system using solar/urine

    International Nuclear Information System (INIS)

    Wu, Wei; Zhou, Ya-Yan; Lin, Mu-Hsuan; Hwang, Jenn-Jiang

    2013-01-01

    Highlights: • The stand-alone hybrid power system is presented. • The urine-to-hydrogen processor is proposed. • Scenario analysis of the hybrid power dispatching and the urine/solar demands is investigated. • The design, modeling and optimization of the hybrid power system is addressed by Aspen Plus and Matlab. - Abstract: The urine turned to hydrogen as an energy conversion process is integrated into a stand-alone hybrid (PV/FC/battery) power generation system. The optimization and simulation of a new urine-to-hydrogen processor is evaluated in Aspen Plus environment. In our approach, the PV generator aims to reduce urine consumption and the lithium-ion battery can compensate the power gap due to the fuel processing delay. Based on prescribed patterns of solar irradiation and the daily load demand of a 30-persons classroom, scenario analyses of the hybrid power dispatching and operational feasibility is addressed

  12. Urine Cytology

    Science.gov (United States)

    Urine cytology Overview Urine cytology is a test to look for abnormal cells in your urine. It's used with other tests and procedures to diagnose ... bladder cancer. Your doctor might recommend a urine cytology test if you have blood in your urine ( ...

  13. Performance evaluation of automated urine microscopy as a rapid, non-invasive approach for the diagnosis of non-gonococcal urethritis.

    Science.gov (United States)

    Pond, Marcus J; Nori, Achyuta V; Patel, Sheel; Laing, Ken; Ajayi, Margarita; Copas, Andrew J; Butcher, Philip D; Hay, Phillip; Sadiq, Syed Tariq

    2015-05-01

    Gram-stained urethral smear (GSUS), the standard point-of-care test for non-gonococcal urethritis (NGU) is operator dependent and poorly specific. The performance of rapid automated urine flow cytometry (AUFC) of first void urine (FVU) white cell counts (UWCC) for predicting Mycoplasma genitalium and Chlamydia trachomatis urethral infections was assessed and its application to asymptomatic infection was evaluated. Receiver operating characteristic curve analysis, determining FVU-UWCC threshold for predicting M. genitalium or C. trachomatis infection was performed on 208 'training' samples from symptomatic patients and subsequently validated using 228 additional FVUs obtained from prospective unselected patients. An optimal diagnostic threshold of >29 UWC/µL gave sensitivities and specificities for either infection of 81.5% (95% CI 65.1% to 91.6%) and 85.8% (79.5% to 90.4%), respectively, compared with 86.8% (71.1% to 95%) and 64.7% (56.9% to 71.7%), respectively, for GSUS, using the training set samples. FVU-UWCC demonstrated sensitivities and specificities of 69.2% (95% CI 48.1% to 84.9%) and 92% (87.2% to 95.2%), respectively, when using validation samples. In asymptomatic patients where GSUS was not used, AUFC would have enabled more infections to be detected compared with clinical considerations only (71.4% vs 28.6%; p=0.03). The correlation between UWCC and bacterial load was stronger for M. genitalium compared with C. trachomatis (τ=0.426, p≤0.001 vs τ=0.295, p=0.022, respectively). AUFC offers improved specificity over microscopy for predicting C. trachomatis or M. genitalium infection. Universal AUFC may enable non-invasive diagnosis of asymptomatic NGU at the PoC. The degree of urethral inflammation exhibits a stronger association with pathogen load for M. genitalium compared with C. trachomatis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. MCP-1 in urine as biomarker of disease activity in Systemic Lupus Erythematosus.

    Science.gov (United States)

    Barbado, Julia; Martin, Debora; Vega, Luisa; Almansa, Raquel; Gonçalves, Lisbeth; Nocito, Mercedes; Jimeno, Antonio; Ortiz de Lejarazu, Raúl; Bermejo-Martin, Jesus F

    2012-11-01

    Conventional clinical parameters are not sensitive or specific enough for detecting ongoing disease activity in the Systemic Lupus Erythematosus (SLE). Measurement of cytokines in urine is an encouraging approach to detection of early flares in this disease. Here we have profiled 27 different cytokines, chemokines and celular growth factors in the urine of 48 patients previously diagnosed of SLE as potential biomarkers of disease activity. Correlation analysis with Bonferroni correction showed that MCP-1 was the only immune mediator which levels in urine correlated directly with the SLE Disease Activity Index 2000 (SLEDAI-2K) score (correlation coefficient, p): MCP-1 (0.45,0.003). MCP-1 correlated inversely with levels of C3 complement protein in serum (-0.50,0.001). MCP-1 showed significant higher levels in patients with severe disease activity in comparison with those exhibiting mild activity. Levels of this chemokine were also higher in patients with severe disease activity in comparison with patients with inactive disease and healthy controls. Areas under receiver operating characteristic curves (AUROC) for detection of severe disease (SLEDAI⩾8) was as follows for MCP-1: [AUROC, (IC95%), p]: [0.81 (0.65-0.96) 0.003]. In addition, MCP-1 showed a good result in the AUROC analysis for detecting renal involvement [0.70 (0.52-0.87) 0.050]. When correlation analysis were repeated excluding those patients with active renal disease (n=14), levels of MCP-1 in urine kept on showing a significant positive association with SLEDAI-2K score. In conclusion, multiplex-based cytokine profiling in urine demonstrated the superiority of MCP-1 over a wide range of cytokines as biomarker of disease activity in SLE. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Urine culture

    Science.gov (United States)

    Culture and sensitivity - urine ... when urinating. You also may have a urine culture after you have been treated for an infection. ... when bacteria or yeast are found in the culture. This likely means that you have a urinary ...

  16. A portable microscopy system for fluorescence, polarized, and brightfield imaging

    Science.gov (United States)

    Gordon, Paul; Wattinger, Rolla; Lewis, Cody; Venancio, Vinicius Paula; Mertens-Talcott, Susanne U.; Coté, Gerard

    2018-02-01

    The use of mobile phones to conduct diagnostic microscopy at the point-of-care presents intriguing possibilities for the advancement of high-quality medical care in remote settings. However, it is challenging to create a single device that can adapt to the ever-varying camera technologies in phones or that can image with the customization that multiple modalities require for applications such as malaria diagnosis. A portable multi-modal microscope system is presented that utilizes a Raspberry Pi to collect and transmit data wirelessly to a myriad of electronic devices for image analysis. The microscopy system is capable of providing to the user correlated brightfield, polarized, and fluorescent images of samples fixed on traditional microscopy slides. The multimodal diagnostic capabilities of the microscope were assessed by measuring parasitemia of Plasmodium falciparum-infected thin blood smears. The device is capable of detecting fluorescently-labeled DNA using FITC excitation (490 nm) and emission (525 nm), the birefringent P. falciparum byproduct hemozoin, and detecting brightfield absorption with a resolution of 0.78 micrometers (element 9-3 of a 1951 Air Force Target). This microscopy system is a novel portable imaging tool that may be a viable candidate for field implementation if challenges of system durability, cost considerations, and full automation can be overcome.

  17. Quantitative Monitoring of Cefradine in Human Urine Using a Luminol/Sulfobutylether-β-Cyclodextrin Chemiluminescence System

    Science.gov (United States)

    Shen, M. X.; Tan, X. J.; Song, Zh. H.

    2018-05-01

    In this paper, a sensitive, rapid, and simple flow-injection chemiluminescence (FI-CL) technique is described for determining cefradine in human urine and capsule samples at the picogram level. The results show that cefradine within 0.1-100.0 nmol/L quantitatively quenches the CL intensity of the luminol/sulfo butylether-β-cyclodextrin (SBE-β-CD) system, with a relative correlation coefficient r of 0.9931. Subsequently, the possible mechanism for the quenching phenomenon is discussed in detail using the FI-CL and molecular docking methods. The proposed CL method, with a detection limit of 0.03 nmol/L (3σ) and relative standard deviations 3.0% (N = 7), is then implemented to monitor the excretion of cefradine in human urine. After orally administration, the cefradine reaches a maximum value of 1.37 ± 0.02 mg/mL at 2.0 h in urine, and the total excretion is 4.41 ± 0.03 mg/mL within 8.0 h. The absorption rate constant ka, the elimination rate constant ke, and the half-life t1/2 are 0.670 ± 0.008 h-1, 0.744 ± 0.005 h-1, and 0.93 ± 0.05 h, respectively.

  18. System and method for compressive scanning electron microscopy

    Science.gov (United States)

    Reed, Bryan W

    2015-01-13

    A scanning transmission electron microscopy (STEM) system is disclosed. The system may make use of an electron beam scanning system configured to generate a plurality of electron beam scans over substantially an entire sample, with each scan varying in electron-illumination intensity over a course of the scan. A signal acquisition system may be used for obtaining at least one of an image, a diffraction pattern, or a spectrum from the scans, the image, diffraction pattern, or spectrum representing only information from at least one of a select subplurality or linear combination of all pixel locations comprising the image. A dataset may be produced from the information. A subsystem may be used for mathematically analyzing the dataset to predict actual information that would have been produced by each pixel location of the image.

  19. Myoglobin urine test

    Science.gov (United States)

    Urine myoglobin; Heart attack - myoglobin urine test; Myositis - myoglobin urine test; Rhabdomyolysis - myoglobin urine test ... The test involves only normal urination, which should cause no discomfort.

  20. Exploring lipids with nonlinear optical microscopy in multiple biological systems

    Science.gov (United States)

    Alfonso-Garcia, Alba

    Lipids are crucial biomolecules for the well being of humans. Altered lipid metabolism may give rise to a variety of diseases that affect organs from the cardiovascular to the central nervous system. A deeper understanding of lipid metabolic processes would spur medical research towards developing precise diagnostic tools, treatment methods, and preventive strategies for reducing the impact of lipid diseases. Lipid visualization remains a complex task because of the perturbative effect exerted by traditional biochemical assays and most fluorescence markers. Coherent Raman scattering (CRS) microscopy enables interrogation of biological samples with minimum disturbance, and is particularly well suited for label-free visualization of lipids, providing chemical specificity without compromising on spatial resolution. Hyperspectral imaging yields large datasets that benefit from tailored multivariate analysis. In this thesis, CRS microscopy was combined with Raman spectroscopy and other label-free nonlinear optical techniques to analyze lipid metabolism in multiple biological systems. We used nonlinear Raman techniques to characterize Meibum secretions in the progression of dry eye disease, where the lipid and protein contributions change in ratio and phase segregation. We employed similar tools to examine lipid droplets in mice livers aboard a spaceflight mission, which lose their retinol content contributing to the onset of nonalcoholic fatty-liver disease. We also focused on atherosclerosis, a disease that revolves around lipid-rich plaques in arterial walls. We examined the lipid content of macrophages, whose variable phenotype gives rise to contrasting healing and inflammatory activities. We also proposed new label-free markers, based on lifetime imaging, for macrophage phenotype, and to detect products of lipid oxidation. Cholesterol was also detected in hepatitis C virus infected cells, and in specific strains of age-related macular degeneration diseased cells by

  1. Quantitative Monitoring of Cefradine in Human Urine Using a Luminol/Sulfobutylether-β-Cyclodextrin Chemiluminescence System

    Science.gov (United States)

    Shen, M. X.; Tan, X. J.; Song, Zh. H.

    2018-05-01

    In this paper, a sensitive, rapid, and simple flow-injection chemiluminescence (FI-CL) technique is described for determining cefradine in human urine and capsule samples at the picogram level. The results show that cefradine within 0.1-100.0 nmol/L quantitatively quenches the CL intensity of the luminol/sulfo butylether-β-cyclodextrin (SBE-β-CD) system, with a relative correlation coefficient r of 0.9931. Subsequently, the possible mechanism for the quenching phenomenon is discussed in detail using the FI-CL and molecular docking methods. The proposed CL method, with a detection limit of 0.03 nmol/L (3σ) and relative standard deviations administration, the cefradine reaches a maximum value of 1.37 ± 0.02 mg/mL at 2.0 h in urine, and the total excretion is 4.41 ± 0.03 mg/mL within 8.0 h. The absorption rate constant ka, the elimination rate constant ke, and the half-life t1/2 are 0.670 ± 0.008 h-1, 0.744 ± 0.005 h-1, and 0.93 ± 0.05 h, respectively.

  2. Optical Imaging and Microscopy Techniques and Advanced Systems

    CERN Document Server

    Török, Peter

    2007-01-01

    This text on contemporary optical systems is intended for optical researchers and engineers, graduate students and optical microscopists in the biological and biomedical sciences. This second edition contains two completely new chapters. In addition most of the chapters from the first edition have been revised and updated. The book consists of three parts: The first discusses high-aperture optical systems, which form the backbone of optical microscopes. An example is a chapter new in the second edition on the emerging field of high numerical aperture diffractive lenses which seems to have particular promise in improving the correction of lenses. In this part particular attention is paid to optical data storage. The second part is on the use of non-linear optical techniques, including nonlinear optical excitation (total internal reflection fluorescence, second and third harmonic generation and two photon microscopy) and non-linear spectroscopy (CARS). The final part of the book presents miscellaneous technique...

  3. Design and installation of a multimode microscopy system

    Science.gov (United States)

    Helm, Johannes P.; Haug, Finn-Mogens S.; Storm, Johan F.; Ottersen, Ole-Petter

    2001-04-01

    We describe design and installation of a multi-mode microscopy core facility in an environment of varied research activity in life-sciences. The experimentators can select any combination of a) microscopes (upright, upright fixed-stage, inverted), b) microscopy modes (widefield, DIC, IRDIC, widefield epifluorescence, transmission LSM, reflection and fluorescence CLSM, MPLSM), c) imaging techniques (direct observation, video observation, photography, quantitative camera-recording, flying spot scanning), d) auxiliary systems (equipment for live specimen imaging, electrophysiology, time-coordinated laser-scanning and electrophysiology, patch-clamp). The equipment is installed on one large vibration-isolating optical table (3m X 1.5m X 0.3m). Electronics, auxiliary equipment, and a fiber-coupled, remotely controlled Ar+-Kr+ laser are mounted in a rack system fixed to the ceiling. The design of the shelves allows the head of the CSLM to be moved to any of the microscopes without increasing critical cable lengths. At the same time easy access to all the units is preserved. The beam of a Titanium-Sapphire laser, controlled by means of an EOM and a prism GVD, is coupled directly to the microscopes. Three mirrors mounted on a single precision translation table are integrated into the beam steering system so that the beam can easily be redirected to any of the microscopes. All the available instruments can be operated by the educated and trained user. The system is popular among researchers in neuroanatomy, embryology, cell biology, molecular biology - including the study of protein interactions, e.g. by means of FRET, and electrophysiology. Its colocalization with an EM facility promises to provide considerable synergy effects.

  4. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    Science.gov (United States)

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL -1 , ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL -1 . Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSDchromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Simple test system for single molecule recognition force microscopy

    International Nuclear Information System (INIS)

    Riener, Christian K.; Stroh, Cordula M.; Ebner, Andreas; Klampfl, Christian; Gall, Alex A.; Romanin, Christoph; Lyubchenko, Yuri L.; Hinterdorfer, Peter; Gruber, Hermann J.

    2003-01-01

    We have established an easy-to-use test system for detecting receptor-ligand interactions on the single molecule level using atomic force microscopy (AFM). For this, avidin-biotin, probably the best characterized receptor-ligand pair, was chosen. AFM sensors were prepared containing tethered biotin molecules at sufficiently low surface concentrations appropriate for single molecule studies. A biotin tether, consisting of a 6 nm poly(ethylene glycol) (PEG) chain and a functional succinimide group at the other end, was newly synthesized and covalently coupled to amine-functionalized AFM tips. In particular, PEG 800 diamine was glutarylated, the mono-adduct NH 2 -PEG-COOH was isolated by ion exchange chromatography and reacted with biotin succinimidylester to give biotin-PEG-COOH which was then activated as N-hydroxysuccinimide (NHS) ester to give the biotin-PEG-NHS conjugate which was coupled to the aminofunctionalized AFM tip. The motional freedom provided by PEG allows for free rotation of the biotin molecule on the AFM sensor and for specific binding to avidin which had been adsorbed to mica surfaces via electrostatic interactions. Specific avidin-biotin recognition events were discriminated from nonspecific tip-mica adhesion by their typical unbinding force (∼40 pN at 1.4 nN/s loading rate), unbinding length (<13 nm), the characteristic nonlinear force-distance relation of the PEG linker, and by specific block with excess of free d-biotin. The convenience of the test system allowed to evaluate, and compare, different methods and conditions of tip aminofunctionalization with respect to specific binding and nonspecific adhesion. It is concluded that this system is well suited as calibration or start-up kit for single molecule recognition force microscopy

  6. Comparative evaluation of three commercial systems for nucleic acid extraction from urine specimens.

    Science.gov (United States)

    Tang, Yi-Wei; Sefers, Susan E; Li, Haijing; Kohn, Debra J; Procop, Gary W

    2005-09-01

    A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation on three systems: the MagNA Pure compact system (Compact), the NucliSens miniMAG extraction instrument (miniMAG), and the BioRobot EZ1 system (EZ1). A total of 75 urine specimens submitted for polyomavirus BK virus detection were used. The human beta-actin gene was detected on 75 (100%), 75 (100%), and 72 (96%) nucleic acid extracts prepared by the miniMAG, EZ1, and Compact, respectively. The miniMAG produced the highest quantity of nucleic acids and the best precision among the three systems. The agreement rate was 100% for BKV detection on nucleic acid extracts prepared by the three extraction systems. When a full panel of specimens was run, the hands-on time and test turnaround time were 105.7 and 121.1 min for miniMAG, 6.1 and 22.6 min for EZ1, and 7.4 and 33.7 min for Compact, respectively. The EZ1 and Compact systems processed automatic nucleic acid extraction properly, providing a good solution to the need for sporadic but emergent specimen detection. The miniMAG yielded the highest quantity of nucleic acids, suggesting that this system would be the best for specimens containing a low number of microorganisms of interest.

  7. Measurement of 239Pu in urine samples at ultra-trace levels using a 1 MV compact AMS system

    International Nuclear Information System (INIS)

    Hernandez-Mendoza, H.; Chamizo, E.; Yllera, A.; Garcia-Leon, M.; Delgado, A.

    2010-01-01

    Routine bioassay monitoring of Pu intake in exposed workers of research and nuclear industry is usually performed by alpha spectrometry. This technique involves large sample volumes of urine and time-consuming preparative and counting protocols. Compact accelerator mass spectrometry (AMS) facilities make feasible the determination of ultra low-level Pu activity concentrations and Pu isotopic ratios in biological samples (blood, urine and feces), being a rapid and cost-effective measurement technique. The plutonium results in urine samples presented here have been obtained on the 1 MV compact AMS system sited at the Centro Nacional de Aceleradores (CNA), in Seville, Spain. In this work, a different methodological approach has been developed alternative to the 'classical' preparation of urine samples for alpha spectrometry. The procedure avoids the Pu precipitation step, and involves acid sample evaporation and acid digestion in a microwave oven. Finally, purification of plutonium was achieved by using chromatography columns filled up with BioRad AG1X2 anion exchange resin (Bio-Rad Laboratories Inc.). The total time needed for analysis is about 10 h, unlike the 'classical' methods based on alpha spectrometry which need about 1 week. At present, it has been demonstrated that this method allows quantifying 239 Pu activity concentrations in urine of, at least, 30 μBq (13 fg 239 Pu). We can conclude that the procedure would be suitable to perform in vitro routine bioassay measurements. Moreover, the innovative application of AMS opens new and interesting analytical alternatives in this field.

  8. Urine Odor

    Science.gov (United States)

    ... doctor. Brunzel NA. Physical examination of urine. In: Fundamentals of Urine and Body Fluid Analysis. 3rd ed. St. Louis, Mo.: Saunders Elsevier; 2013:97. McPherson RA, et al., eds. Henry's Clinical Diagnosis and Management by Laboratory Methods. 23rd ed. St. Louis, Mo.: ...

  9. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  10. Aqueous Colloid + Polymer Depletion System for Confocal Microscopy and Rheology

    Science.gov (United States)

    Park, Nayoung; Umanzor, Esmeralda J.; Conrad, Jacinta C.

    2018-05-01

    We developed a model depletion system with colloidal particles that were refractive index- and density-matched to 80 (w/w)% glycerol in water, and characterized the effect of interparticle interactions on the structure and dynamics of non-equilibrium phases. 2,2,2-trifluoroethyl methacrylate-co-tert-butyl methacrylate copolymer particles were synthesized following Kodger et al. (Sci. Rep. 5, 14635 (2015)). Particles were dispersed in glycerol/water solutions to generate colloidal suspensions with good control over electrostatic interactions and a moderately high background viscosity of 55 mPa-s. To probe the effects of charge screening and depletion attractions on the suspension phase behavior, we added NaCl and polyacrylamide (M_w = 186 kDa) at various concentrations to particle suspensions formulated at volume fractions of phi = 0.05 and 0.3 and imaged the suspensions using confocal microscopy. The particles were nearly hard spheres at a NaCl concentration of 20 mM, but aggregated when the concentration of NaCl was further increased. Changes in the particle structure and dynamics with increasing concentration of the depletant polyacrylamide followed the trends expected from earlier experiments on depletion-driven gelation. Additionally, we measured the viscosity and corrected first normal stress difference of suspensions formulated at phi = 0.4 with and without added polymer. The solvent viscosity was suitable for rheology measurements without the onset of instabilities such as secondary flows or edge fracture. These results validate this system as an alternative to one common model system, suspensions of poly(methyl methacrylate) particles and polystyrene depletants in organic solvents, for investigating phase behavior and flow properties in attractive colloidal suspensions.

  11. Black Urine

    Directory of Open Access Journals (Sweden)

    Rahim Vakili

    2016-06-01

    Full Text Available A 2-year-old boy was born at term of healthy, non-consanguineous Iranian parents. His mother attended in the clinic with the history of sometimes discoloration of diapers after passing urine. She noticed that first at the age of one month with intensified in recent months. His Physical examination and growth parameters were normal. His mother denied taking any medication (sorbitol, nitrofurantoin, metronidazole, methocarbamol, sena and methyldopa (5. Qualitative urine examination showed dark black discoloration. By this history, alkaptonuria was the most clinical suspicious. A 24-hour-urine sample was collected and sent for quantitative measurements. The urine sample was highly positive for homogentisic acid and negative for porphyrin metabolites.

  12. Urine Preservative

    Science.gov (United States)

    Smith, Scott M. (Inventor); Nillen, Jeannie (Inventor)

    2001-01-01

    Disclosed is CPG, a combination of a chlorhexidine salt (such as chlorhexidine digluconate, chlorhexidine diacetate, or chlorhexidine dichloride) and n-propyl gallate that can be used at ambient temperatures as a urine preservative.

  13. Urine Color

    Science.gov (United States)

    ... drugs can darken urine, including the antimalarial drugs chloroquine and primaquine, the antibiotics metronidazole (Flagyl) and nitrofurantoin ( ... Mayo Clinic Footer Legal Conditions and Terms Any use of this site constitutes your agreement to the ...

  14. Immunoelectrophoresis - urine

    Science.gov (United States)

    ... from an infant, you may need extra collection bags. How the Test will Feel The test involves ... urine, it normally consists of mainly albumin. Normal value ranges may vary slightly among different laboratories. Talk ...

  15. Silicon technology-based micro-systems for atomic force microscopy/photon scanning tunnelling microscopy.

    Science.gov (United States)

    Gall-Borrut, P; Belier, B; Falgayrettes, P; Castagne, M; Bergaud, C; Temple-Boyer, P

    2001-04-01

    We developed silicon nitride cantilevers integrating a probe tip and a wave guide that is prolonged on the silicon holder with one or two guides. A micro-system is bonded to a photodetector. The resulting hybrid system enables us to obtain simultaneously topographic and optical near-field images. Examples of images obtained on a longitudinal cross-section of an optical fibre are shown.

  16. Ketones urine test

    Science.gov (United States)

    Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...

  17. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: FOUNDATIONS FOR MEASUREMENTS, QUANTITATION AND SPECTROSCOPY

    Science.gov (United States)

    The confocal laser-scanning microscopy (CLSM) has enormous potential in many biological fields. The goal of a CLSM is to acquire and quantify fluorescence and in some instruments acquire spectral characterization of the emitted signal. The accuracy of these measurements demands t...

  18. Energy efficient reconcentration of diluted human urine using ion exchange membranes in bioelectrochemical systems.

    Science.gov (United States)

    Tice, Ryan C; Kim, Younggy

    2014-11-01

    Nutrients can be recovered from source separated human urine; however, nutrient reconcentration (i.e., volume reduction of collected urine) requires energy-intensive treatment processes, making it practically difficult to utilize human urine. In this study, energy-efficient nutrient reconcentration was demonstrated using ion exchange membranes (IEMs) in a microbial electrolysis cell (MEC) where substrate oxidation at the MEC anode provides energy for the separation of nutrient ions (e.g., NH4(+), HPO4(2-)). The rate of nutrient separation was magnified with increasing number of IEM pairs and electric voltage application (Eap). Ammonia and phosphate were reconcentrated from diluted human urine by a factor of up to 4.5 and 3.0, respectively (Eap = 1.2 V; 3-IEM pairs). The concentrating factor increased with increasing degrees of volume reduction, but it remained stationary when the volume ratio between the diluate (urine solution that is diluted in the IEM stack) and concentrate (urine solution that is reconcentrated) was 6 or greater. The energy requirement normalized by the mass of nutrient reconcentrated was 6.48 MJ/kg-N (1.80 kWh/kg-N) and 117.6 MJ/kg-P (32.7 kWh/kg-P). In addition to nutrient separation, the examined MEC reactor with three IEM pairs showed 54% removal of COD (chemical oxygen demand) in 47-hr batch operation. The high sulfate concentration in human urine resulted in substantial growth of both of acetate-oxidizing and H2-oxidizing sulfate reducing bacteria, greatly diminishing the energy recovery and Coulombic efficiency. However, the high microbial activity of sulfate reducing bacteria hardly affected the rate of nutrient reconcentration. With the capability to reconcentrate nutrients at a minimal energy consumption and simultaneous COD removal, the examined bioelectrochemical treatment method with an IEM application has a potential for practical nutrient recovery and sustainable treatment of source-separated human urine. Copyright © 2014

  19. Calcium - urine

    Science.gov (United States)

    ... Female urinary tract Male urinary tract Calcium urine test References Bringhurst FR, Demay MB, Kronenberg HM. Hormones and disorders of mineral metabolism. In: Melmed S, Polonsky KS, Larsen PR, Kronenberg HM, eds. Williams Textbook of Endocrinology . 13th ed. Philadelphia, PA: Elsevier; ...

  20. The performance of fully automated urine analysis results for predicting the need of urine culture test

    Directory of Open Access Journals (Sweden)

    Hatice Yüksel

    2014-06-01

    Full Text Available Objectives: Urinalysis and urine culture are most common tests for diagnosis of urinary tract infections. The aim of our study is to examine the diagnostic performance of urine analysis and the role of urine analysis to determine the requirements for urine culture. Methods: Urine culture and urine analysis results of 362 patients were retrospectively analyzed. Culture results were taken as a reference for chemical and microscopic examination of urine and diagnostic accuracy of the test parameters, that may be a marker for urinary tract infection, and the performance of urine analysis were calculated for predicting the urine culture requirements. Results: A total of 362 urine culture results of patients were evaluated and 67% of them were negative. The results of leukocyte esterase and nitrite in chemical analysis and leukocytes and bacteria in microscopic analysis were normal in 50.4% of culture negative urines. In diagnostic accuracy calculations, leukocyte esterase (86.1% and microscopy leukocytes (88.0% were found with high sensitivity, nitrite (95.4% and bacteria (86.6% were found with high specificity. The area under the curve was calculated as 0.852 in ROC analysis for microscopic examination for leukocytes. Conclusion: Full-automatic urine devices can provide sufficient diagnostic accuracy for urine analysis. The evaluation of urine analysis results in an effective way can predict the necessity for urine culture requests and especially may contribute to a reduction in the work load and cost. J Clin Exp Invest 2014; 5 (2: 286-289

  1. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  2. Systemic perturbations of key metabolites in diabetic rats during the evolution of diabetes studied by urine metabonomics.

    Directory of Open Access Journals (Sweden)

    Mimi Guan

    Full Text Available BACKGROUND: Elucidation of metabolic profiles during diabetes progression helps understand the pathogenesis of diabetes mellitus. In this study, urine metabonomics was used to identify time-related metabolic changes that occur during the development of diabetes mellitus and characterize the biochemical process of diabetes on a systemic, metabolic level. METHODOLOGY/PRINCIPAL FINDINGS: Urine samples were collected from diabetic rats and age-matched controls at different time points: 1, 5, 10, and 15 weeks after diabetes modeling. (1H nuclear magnetic resonance ((1H NMR spectra of the urine samples were obtained and analyzed by multivariate data analysis and quantitative statistical analysis. The metabolic patterns of diabetic groups are separated from the controls at each time point, suggesting that the metabolic profiles of diabetic rats were markedly different from the controls. Moreover, the samples from the diabetic 1-wk group are closely associated, whereas those of the diabetic 15-wk group are scattered, suggesting that the presence of various of complications contributes significantly to the pathogenesis of diabetes. Quantitative analysis indicated that urinary metabolites related to energy metabolism, tricarboxylic acid (TCA cycle, and methylamine metabolism are involved in the evolution of diabetes. CONCLUSIONS/SIGNIFICANCE: The results highlighted that the numbers of metabolic changes were related to diabetes progression, and the perturbed metabolites represent potential metabolic biomarkers and provide clues that can elucidate the mechanisms underlying the generation and development of diabetes as well as its complication.

  3. Performance of a veterinary urine dipstick paddle system for diagnosis and identification of urinary tract infections in dogs and cats.

    Science.gov (United States)

    Ybarra, Winnie L; Sykes, Jane E; Wang, Yenlie; Byrne, Barbara A; Westropp, Jodi L

    2014-04-01

    To evaluate the performance of a veterinary urine dipstick paddle (UDP) for diagnosis and identification of urinary tract infection (UTI) in dogs and cats. Prospective, randomized, blinded study. 207 urine specimens. UDPs were inoculated by 2 investigators and incubated according to manufacturer's instructions. Results, including presence or absence of bacterial growth, organism counts, and identification of uropathogens, were compared between investigators and with microbiology laboratory results. A subset of UDPs with bacterial growth was submitted to the laboratory for confirmation. The laboratory reported 64 (30.9%) specimens had growth of bacteria. Bacterial growth was reported for 63 (30.4%) and 58 (28.0%) of the UDPs by investigators 1 and 2, respectively. Sensitivity and specificity of the UDP for detection of bacterial growth were 97.3% and 98.6%, respectively, for investigator 1 and 89.1% and 99.3%, respectively, for investigator 2. For UPDs with ≥ 10(5) colony-forming units/mL, organism counts correlated well between the laboratory and investigators 1 (r = 0.95) and 2 (r = 0.89). Pathogen identification was not always accurate. Only 25 of 33 (75.8%) UDPs submitted for confirmation yielded bacteria consistent with those isolated from the original bacterial culture of urine. The veterinary UDP system was a sensitive test for screening patients for bacterial UTI, but uropathogen identification was not always accurate. When UDPs have bacterial growth, a fresh urine specimen should be submitted to the laboratory to confirm the identity of the organisms and to permit antimicrobial susceptibility testing.

  4. Auditing smear microscopy results according to time to detection using the BACTEC™ MGIT™ TB system.

    Science.gov (United States)

    Elsaghier, A A F

    2015-09-01

    Smear microscopy is a rapid method for the identification of the most infectious patients with mycobacterial infection. Suboptimal smear microscopy may significantly compromise or delay patient isolation and contact tracing. A stringent method for auditing mycobacterial smear results is thus needed. This article proposes an auditing tool based on time to detection (TTD) of culture-positive samples using the automated BACTEC™ MGIT™ 960 TB system. In our study, sputum samples subjected to liquefaction and concentration before staining with a TTD of ≤ 13 days using the BACTEC system should be positive on smear microscopy.

  5. QUALITY ASSESSMENT OF CONFOCAL MICROSCOPY SLIDE-BASED SYSTEMS: INSTABLITY

    Science.gov (United States)

    Background: All slide-based fluorescence cytometry detections systems basically include an excitation light source, intermediate optics, and a detection device (CCD or PMT). Occasionally, this equipment becomes unstable, generating unreliable and inferior data. Methods: A num...

  6. The Mayak Worker Dosimetry System (MWDS-2013): a comparison of intakes based on urine versus autopsy data from Mayak workers using the Leggett systemic model for plutonium

    International Nuclear Information System (INIS)

    Birchall, A.; Dorrian, M.-D.; Suslova, K. G.; Sokolova, A. B.

    2017-01-01

    The Mayak Worker Dosimetry System-2013 (MWDS-2013) uses a model developed by Leggett and colleagues to represent the biokinetic behaviour of plutonium after uptake to blood. Of particular importance, with regard to estimating intakes (and doses), is the distribution of activity between urine and body organs (particularly liver and skeleton). In this study, measurement data (urine and autopsy) from around 500 Mayak workers have been used to validate use of this model. A robust method has been developed and used to estimate intakes from both urine and autopsy data separately, and the ratio of these estimates has been calculated for each worker. The geometric mean ratio has been shown to lie within a range of 0.92-1.14, depending on assumptions made. Since this range includes 1, the hypothesis that the model is unbiased with regard to estimating intakes either with urine or autopsy data cannot be rejected on the basis of these data. This lends weight to the argument for increasing the MWDS-2013 cohort to include an additional 500 workers for whom only autopsy data are available, and who have previously been excluded from the cohort. Future directions in which this work could be extended are also suggested. (authors)

  7. Knemometry is more sensitive to systemic effects of inhaled corticosteroids in children with asthma than 24-hour urine cortisol excretion

    DEFF Research Database (Denmark)

    Chawes, Bo; Nilsson, Erik; Nørgaard, Sarah

    2017-01-01

    Background: Pharmacodynamic assessment of the systemic effect of inhaled corticosteroids (ICSs) is often done by measuring 24-hour urine free cortisol (UFC) excretion. Knemometry assessing short-term lower-leg growth rate (LLGR) is a more rarely used alternative. Objective: The primary aim...... of this study was to compare the sensitivity of LLGR and 24-hour UFC excretion for evaluating systemic exposure to ICSs in prepubertal children with asthma. The secondary aim was to evaluate factors influencing the precision of LLGR calculated by the traditional 1 leg nonparametric method versus a new 2 leg...... parametric method. Methods: The study evaluated 60 children with mild asthma aged 5 to 12 years participating in a randomized controlled trial of ICSs with longitudinal concomitant assessments of LLGR and 24-hour UFC excretion. The sensitivity of the safety assessments was analyzed by comparing LLGR and 24...

  8. Superresolution upgrade for confocal spinning disk systems using image scanning microscopy (Conference Presentation)

    Science.gov (United States)

    Isbaner, Sebastian; Hähnel, Dirk; Gregor, Ingo; Enderlein, Jörg

    2017-02-01

    Confocal Spinning Disk Systems are widely used for 3D cell imaging because they offer the advantage of optical sectioning at high framerates and are easy to use. However, as in confocal microscopy, the imaging resolution is diffraction limited, which can be theoretically improved by a factor of 2 using the principle of Image Scanning Microscopy (ISM) [1]. ISM with a Confocal Spinning Disk setup (CSDISM) has been shown to improve contrast as well as lateral resolution (FWHM) from 201 +/- 20 nm to 130 +/- 10 nm at 488 nm excitation. A minimum total acquisition time of one second per ISM image makes this method highly suitable for 3D live cell imaging [2]. Here, we present a multicolor implementation of CSDISM for the popular Micro-Manager Open Source Microscopy platform. Since changes in the optical path are not necessary, this will allow any researcher to easily upgrade their standard Confocal Spinning Disk system at remarkable low cost ( 5000 USD) with an ISM superresolution option. [1]. Müller, C.B. and Enderlein, J. Image Scanning Microscopy. Physical Review Letters 104, (2010). [2]. Schulz, O. et al. Resolution doubling in fluorescence microscopy with confocal spinning-disk image scanning microscopy. Proceedings of the National Academy of Sciences of the United States of America 110, 21000-5 (2013).

  9. Reducing unnecessary culturing: a systems approach to evaluating urine culture ordering and collection practices among nurses in two acute care settings

    Directory of Open Access Journals (Sweden)

    Robert Redwood

    2018-01-01

    Full Text Available Abstract Background Inappropriate ordering and acquisition of urine cultures leads to unnecessary treatment of asymptomatic bacteriuria (ASB. Treatment of ASB contributes to antimicrobial resistance particularly among hospital-acquired organisms. Our objective was to investigate urine culture ordering and collection practices among nurses to identify key system-level and human factor barriers and facilitators that affect optimal ordering and collection practices. Methods We conducted two focus groups, one with ED nurses and the other with ICU nurses. Questions were developed using the Systems Engineering Initiative for Patient Safety (SEIPS framework. We used iterative categorization (directed content analysis followed by summative content analysis to code and analyze the data both deductively (using SEIPS domains and inductively (emerging themes. Results Factors affecting optimal urine ordering and collection included barriers at the person, process, and task levels. For ED nurses, barriers included patient factors, physician communication, reflex culture protocols, the electronic health record, urinary symptoms, and ED throughput. For ICU nurses, barriers included physician notification of urinalysis results, personal protective equipment, collection technique, patient body habitus, and Foley catheter issues. Conclusions We identified multiple potential process barriers to nurse adherence with evidence-based recommendations for ordering and collecting urine cultures in the ICU and ED. A systems approach to identifying barriers and facilitators can be useful to design interventions for improving urine ordering and collection practices.

  10. Microcontroller-driven fluid-injection system for atomic force microscopy.

    Science.gov (United States)

    Kasas, S; Alonso, L; Jacquet, P; Adamcik, J; Haeberli, C; Dietler, G

    2010-01-01

    We present a programmable microcontroller-driven injection system for the exchange of imaging medium during atomic force microscopy. Using this low-noise system, high-resolution imaging can be performed during this process of injection without disturbance. This latter circumstance was exemplified by the online imaging of conformational changes in DNA molecules during the injection of anticancer drug into the fluid chamber.

  11. Urine - abnormal color

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  12. A urine-fuelled soil-based bioregenerative life support system for long-term and long-distance manned space missions

    Science.gov (United States)

    Maggi, Federico; Tang, Fiona H. M.; Pallud, Céline; Gu, Chuanhui

    2018-05-01

    A soil-based cropping unit fuelled with human urine for long-term manned space missions was investigated with the aim to analyze whether a closed-loop nutrient cycle from human liquid wastes was achievable. Its ecohydrology and biogeochemistry were analysed in microgravity with the use of an advanced computational tool. Urine from the crew was used to supply primary (N, P, and K) and secondary (S, Ca and Mg) nutrients to wheat and soybean plants in the controlled cropping unit. Breakdown of urine compounds into primary and secondary nutrients as well as byproduct gases, adsorbed, and uptake fractions were tracked over a period of 20 years. Results suggested that human urine could satisfy the demand of at least 3 to 4 out of 6 nutrients with an offset in pH and salinity tolerable by plants. It was therefore inferred that a urine-fuelled life support system can introduce a number of advantages including: (1) recycling of liquids wastes and production of food; (2) forgiveness of neglect as compared to engineered electro-mechanical systems that may fail under unexpected or unplanned conditions; and (3) reduction of supply and waste loads during space missions.

  13. An electromechanical material testing system for in situ electron microscopy and applications

    OpenAIRE

    Zhu, Yong; Espinosa, Horacio D.

    2005-01-01

    We report the development of a material testing system for in situ electron microscopy (EM) mechanical testing of nanostructures. The testing system consists of an actuator and a load sensor fabricated by means of surface micromachining. This previously undescribed nanoscale material testing system makes possible continuous observation of the specimen deformation and failure with subnanometer resolution, while simultaneously measuring the applied load electronically with nanonewton resolution...

  14. Development of a new light collection and detection system optimized for ion beam induced fluorescence microscopy

    International Nuclear Information System (INIS)

    Vanga, Sudheer Kumar; Mi, Zhaohong; Koh, Long Cheng; Tao, Ye; Bettiol, Andrew A.; Watt, Frank

    2015-01-01

    Ion beam induced fluorescence microscopy is a new imaging technique which has the potential to achieve sub-50 nm spatial resolution fluorescence images. Currently the resolution of the technique has been limited to around 150 nm mainly because of inefficient collection and detection of emitted photons from the sample. To overcome this limitation, a new light collection system based on a custom made parabolic mirror is employed to enhance the fluorescence collection. The custom made mirror is designed so as to obtain both structural (scanning transmission ion microscopy) and ion beam induced fluorescence imaging simultaneously. The design and characterization of the parabolic mirror is discussed in detail

  15. Microscopy imaging system and method employing stimulated raman spectroscopy as a contrast mechanism

    Science.gov (United States)

    Xie, Xiaoliang Sunney [Lexington, MA; Freudiger, Christian [Boston, MA; Min, Wei [Cambridge, MA

    2011-09-27

    A microscopy imaging system includes a first light source for providing a first train of pulses at a first center optical frequency .omega..sub.1, a second light source for providing a second train of pulses at a second center optical frequency .omega..sub.2, a modulator system, an optical detector, and a processor. The modulator system is for modulating a beam property of the second train of pulses at a modulation frequency f of at least 100 kHz. The optical detector is for detecting an integrated intensity of substantially all optical frequency components of the first train of pulses from the common focal volume by blocking the second train of pulses being modulated. The processor is for detecting, a modulation at the modulation frequency f, of the integrated intensity of the optical frequency components of the first train of pulses to provide a pixel of an image for the microscopy imaging system.

  16. The urine marker test

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Jensen, Stine Nylandsted; Elsborg, Peter

    2016-01-01

    BACKGROUND: Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured...... that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs......) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. OBJECTIVE: The objective of this study was to investigate the use of the urine marker during urine doping control testing. METHODS: Two studies investigated athletes' acceptance...

  17. Perspective: Differential dynamic microscopy extracts multi-scale activity in complex fluids and biological systems

    Science.gov (United States)

    Cerbino, Roberto; Cicuta, Pietro

    2017-09-01

    Differential dynamic microscopy (DDM) is a technique that exploits optical microscopy to obtain local, multi-scale quantitative information about dynamic samples, in most cases without user intervention. It is proving extremely useful in understanding dynamics in liquid suspensions, soft materials, cells, and tissues. In DDM, image sequences are analyzed via a combination of image differences and spatial Fourier transforms to obtain information equivalent to that obtained by means of light scattering techniques. Compared to light scattering, DDM offers obvious advantages, principally (a) simplicity of the setup; (b) possibility of removing static contributions along the optical path; (c) power of simultaneous different microscopy contrast mechanisms; and (d) flexibility of choosing an analysis region, analogous to a scattering volume. For many questions, DDM has also advantages compared to segmentation/tracking approaches and to correlation techniques like particle image velocimetry. The very straightforward DDM approach, originally demonstrated with bright field microscopy of aqueous colloids, has lately been used to probe a variety of other complex fluids and biological systems with many different imaging methods, including dark-field, differential interference contrast, wide-field, light-sheet, and confocal microscopy. The number of adopting groups is rapidly increasing and so are the applications. Here, we briefly recall the working principles of DDM, we highlight its advantages and limitations, we outline recent experimental breakthroughs, and we provide a perspective on future challenges and directions. DDM can become a standard primary tool in every laboratory equipped with a microscope, at the very least as a first bias-free automated evaluation of the dynamics in a system.

  18. Recommendations for the design and the installation of large laser scanning microscopy systems

    Science.gov (United States)

    Helm, P. Johannes

    2012-03-01

    Laser Scanning Microscopy (LSM) has since the inventions of the Confocal Scanning Laser Microscope (CLSM) and the Multi Photon Laser Scanning Microscope (MPLSM) developed into an essential tool in contemporary life science and material science. The market provides an increasing number of turn-key and hands-off commercial LSM systems, un-problematic to purchase, set up and integrate even into minor research groups. However, the successful definition, financing, acquisition, installation and effective use of one or more large laser scanning microscopy systems, possibly of core facility character, often requires major efforts by senior staff members of large academic or industrial units. Here, a set of recommendations is presented, which are helpful during the process of establishing large systems for confocal or non-linear laser scanning microscopy as an effective operational resource in the scientific or industrial production process. Besides the description of technical difficulties and possible pitfalls, the article also illuminates some seemingly "less scientific" processes, i.e. the definition of specific laboratory demands, advertisement of the intention to purchase one or more large systems, evaluation of quotations, establishment of contracts and preparation of the local environment and laboratory infrastructure.

  19. Optical coherent tomography and fluorescent microscopy for the study of meningeal lymphatic systems

    Science.gov (United States)

    Semyachkina-Glushkovskaya, O.; Abdurashitov, A.; Namykin, A.; Fedosov, I.; Pavlov, A.; Karavaev, A.; Sindeeva, O.; Shirokov, A.; Ulanova, M.; Shushunova, N.; Khorovodov, A.; Agranovich, I.; Bodrova, A.; Sagatova, M.; Shareef, Ali Esmat; Saranceva, E.; Dvoryatkina, M.; Tuchin, V.

    2018-04-01

    The development of novel technologies for the imaging of meningeal lymphatic vessels is one of the amazing trends of biophotonics thanks to discovery of brain lymphatics over several years ago. However, there is the limited technologies exist for the study of lymphatics in vivo because lymphatic vessels are transparent with a low speed flow of lymph. Here we demonstrate the successful application of fluorescent microscopy for the imaging of lymphatic system in the mouse brain in vivo.

  20. Micropollutants in closed life-support systems: the case of triclosan, a biocide excreted via urine

    Science.gov (United States)

    Mastroleo, Felice; Pycke, Benny; Boon, Nico; de Wever, Heleen; Hendrickx, Larissa; Mastroleo, Felice; Wattiez, Ruddy; Mergeay, Max; Verstraete, Willy

    OBJECTIVES: The impact of triclosan on the growth and physiology of the bacterium Rhodospirillum rubrum was studied in the frame of the regenerative life-support system, Micro- Ecological Life Support System Alternative (MELiSSA). A wide range of compounds, such as steroid hormones, pharmaceuticals and personal care products, might enter the life support system via the excrements that are to be treated and recycled. Triclosan was chosen as the first compound to be tested because MELiSSA is a closed system, which is consequently particularly sensitive to compounds inhibiting the microbial metabolism. Because triclosan is increasingly used as an antimicrobial biocide in hygienic formulations (such as toothpaste, mouthwash, deodorants, etc.) and due to its chemical stability, it is considered an emerging pollutant in terrestrial ecosystems. METHODS: In a first phase, the triclosan concentration expected in the life-support system was estimated, the Minimal Inhibitory Concentration (MIC) was determined via plating, and the effect on growth kinetics was assessed by comparing growth parameters in the Gompertz model. In a second phase, the secondary effects of triclosan on cell physiology and gene expression were studied through flow-cytometry and microarray analyses, respectively. RESULTS: Based on the pharmacokinetic data from literature, the predicted concentration range is estimated to be 6-25µg/L triclosan in the Rhodospirillum rubrum compartment of the MELiSSA. The minimal inhibitory concentration of triclosan was determined to be 71 µg/L after 7 days of exposure on Sistrom medium. Upon exposure to 50-200µg/L triclosan, triclosan-resistant mutants of Rhodospirillum rubrum arose spontaneously at high frequency (3.1 ∗ 10 - 4). Analysis of the growth kinetics of the wild-type revealed that triclosan causes an important elongation of the lag-phase and a decrease in growth rate. At concentrations higher than 75mg/L(LD = 500mg/L), triclosan is bactericidal to wild

  1. Systems and methods for selective detection and imaging in coherent Raman microscopy by spectral excitation shaping

    Science.gov (United States)

    Xie, Xiaoliang Sunney; Freudiger, Christian; Min, Wei

    2016-03-15

    A microscopy imaging system is disclosed that includes a light source system, a spectral shaper, a modulator system, an optics system, an optical detector and a processor. The light source system is for providing a first train of pulses and a second train of pulses. The spectral shaper is for spectrally modifying an optical property of at least some frequency components of the broadband range of frequency components such that the broadband range of frequency components is shaped producing a shaped first train of pulses to specifically probe a spectral feature of interest from a sample, and to reduce information from features that are not of interest from the sample. The modulator system is for modulating a property of at least one of the shaped first train of pulses and the second train of pulses at a modulation frequency. The optical detector is for detecting an integrated intensity of substantially all optical frequency components of a train of pulses of interest transmitted or reflected through the common focal volume. The processor is for detecting a modulation at the modulation frequency of the integrated intensity of substantially all of the optical frequency components of the train of pulses of interest due to the non-linear interaction of the shaped first train of pulses with the second train of pulses as modulated in the common focal volume, and for providing an output signal for a pixel of an image for the microscopy imaging system.

  2. Urine specific gravity test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  3. Maple syrup urine disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000373.htm Maple syrup urine disease To use the sharing features on this page, please enable JavaScript. Maple syrup urine disease (MSUD) is a disorder in ...

  4. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    Directory of Open Access Journals (Sweden)

    Fatma Demet Ä°nce

    2016-08-01

    Full Text Available Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA, Dirui FUS-200 (DIRUI Industrial Co., China automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient and the rates within the same grading were evaluated. Results: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. Conclusion: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Keywords: Urinalysis, Autoanalysis, Microscopy

  5. Urine Tests (For Parents)

    Science.gov (United States)

    ... the urine sample. In certain situations, a sterile bag can be placed around a baby’s diaper area to collect a urine sample. If you have any questions about urine tests, talk with your doctor. Reviewed by: Yamini Durani, MD ...

  6. An electromechanical material testing system for in situ electron microscopy and applications.

    Science.gov (United States)

    Zhu, Yong; Espinosa, Horacio D

    2005-10-11

    We report the development of a material testing system for in situ electron microscopy (EM) mechanical testing of nanostructures. The testing system consists of an actuator and a load sensor fabricated by means of surface micromachining. This previously undescribed nanoscale material testing system makes possible continuous observation of the specimen deformation and failure with subnanometer resolution, while simultaneously measuring the applied load electronically with nanonewton resolution. This achievement was made possible by the integration of electromechanical and thermomechanical components based on microelectromechanical system technology. The system capabilities are demonstrated by the in situ EM testing of free-standing polysilicon films, metallic nanowires, and carbon nanotubes. In particular, a previously undescribed real-time instrumented in situ transmission EM observation of carbon nanotubes failure under tensile load is presented here.

  7. Compact three-dimensional super-resolution system based on fluorescence emission difference microscopy

    Science.gov (United States)

    Zhu, Dazhao; Chen, Youhua; Fang, Yue; Hussain, Anwar; Kuang, Cuifang; Zhou, Xiaoxu; Xu, Yingke; Liu, Xu

    2017-12-01

    A compact microscope system for three-dimensional (3-D) super-resolution imaging is presented. The super-resolution capability of the system is based on a size-reduced effective 3-D point spread function generated through the fluorescence emission difference (FED) method. The appropriate polarization direction distribution and manipulation allows the panel active area of the spatial light modulator to be fully utilized. This allows simultaneous modulation of the incident light by two kinds of phase masks to be performed with a single spatial light modulator in order to generate a 3-D negative spot. The system is more compact than standard 3-D FED systems while maintaining all the advantages of 3-D FED microscopy. The experimental results demonstrated the improvement in 3-D resolution by nearly 1.7 times and 1.6 times compared to the classic confocal resolution in the lateral and axial directions, respectively.

  8. Scanning Tunneling Microscopy Analysis of a Pentacene/Graphene/SiC(0001) system

    Science.gov (United States)

    Yost, Andrew; Suzer, Ozgun; Smerdon, Joseph; Chien, Teyu; Guest, Jeffrey

    2014-03-01

    A complete understanding of the structure of molecular assemblies, as well as an understanding of donor-acceptor interactions is crucial in the development of emergent molecular electronics technologies such as organic photovoltaics. The pentacene (C22H14) is a good electron donor in Pentacene-C60 system, which is a model system of an organic photovoltaic cell.. Here we present scanning tunneling microscopy studies of the pentacene(Pn) molecule on Graphene(G) that is epitaxially grown on SiC(0001). In addition to the morphologies reported in literature, several new structures of Pn on on G/SiC(0001) were observed with different periodicity and registry both in monolayer and bilayer coverages of molecules on the surface. Preliminary scanning tunneling spectroscopy of the molecular system is also discussed; well-isolated states and a large HOMO-LUMO gap indicate the Pn is weakly coupled to the grapheme and underlying substrate.

  9. Reliability of widefield capillary microscopy to measure nailfold capillary density in systemic sclerosis.

    Science.gov (United States)

    Hudson, M; Masetto, A; Steele, R; Arthurs, E; Baron, M

    2010-01-01

    To determine intra- and inter-observer reliability of widefield microscopy to measure nailfold capillary density in patients with systemic sclerosis (SSc). Five SSc patients were examined with a STEMV-8 Zeiss biomicroscope with 50x magnification. The nailfold of the second, third, fourth and fifth fingers of both hands of each patient were photographed twice by each of two observers, once in the morning and again in the afternoon (total of 32 pictures). Two raters reviewed the photographs to produce capillary density readings. Intra- and inter-rater reliability of the readings were computed using intra-class correlations (ICC). Additional analyses were undertaken to determine the impact of other sources of variability in the data, namely patient, finger, technician and time. Intra-and inter-rater reliability were substantial (ICC 0.72-0.84) when raters were reading the same photographs or photographs taken at the same time of day. Agreement was only fair between morning and afternoon density readings (ICC 0.30-0.37). Patients, individual fingers and technician accounted for a large part of the variability in the data (combined variance component of 7.69 out of the total 12.23). The coefficient of variation of widefield microscopy was 24%. Although intra- and inter-rater reliability of nailfold capillary density measurements using widefield microscopy are good, proper standardisation of the conditions under which capillaroscopy is done and better imaging of nailfold capillary abnormalities should be considered if nailfold capillary density is to be used as an outcome measure in multi-centre clinical trials in SSc.

  10. Ultra-high vacuum compatible optical chopper system for synchrotron x-ray scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hao, E-mail: hc000211@ohio.edu [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Nanoscale and Quantum Phenomena Institute, Physics & Astronomy Department, Ohio University, Athens, Ohio 45701 (United States); Cummings, Marvin; Shirato, Nozomi; Stripe, Benjamin; Preissner, Curt; Freeland, John W. [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Rosenmann, Daniel [Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Kersell, Heath; Hla, Saw-Wai [Nanoscale and Quantum Phenomena Institute, Physics & Astronomy Department, Ohio University, Athens, Ohio 45701 (United States); Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Rose, Volker, E-mail: vrose@anl.gov [Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States); Center for Nanoscale Materials, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States)

    2016-01-28

    High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

  11. Calcium in Urine Test

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Calcium, Serum; Calcium and Phosphates, Urine; ...

  12. A system architecture for online data interpretation and reduction in fluorescence microscopy

    Science.gov (United States)

    Röder, Thorsten; Geisbauer, Matthias; Chen, Yang; Knoll, Alois; Uhl, Rainer

    2010-01-01

    In this paper we present a high-throughput sample screening system that enables real-time data analysis and reduction for live cell analysis using fluorescence microscopy. We propose a novel system architecture capable of analyzing a large amount of samples during the experiment and thus greatly minimizing the post-analysis phase that is the common practice today. By utilizing data reduction algorithms, relevant information of the target cells is extracted from the online collected data stream, and then used to adjust the experiment parameters in real-time, allowing the system to dynamically react on changing sample properties and to control the microscope setup accordingly. The proposed system consists of an integrated DSP-FPGA hybrid solution to ensure the required real-time constraints, to execute efficiently the underlying computer vision algorithms and to close the perception-action loop. We demonstrate our approach by addressing the selective imaging of cells with a particular combination of markers. With this novel closed-loop system the amount of superfluous collected data is minimized, while at the same time the information entropy increases.

  13. Lab-On-Chip Clinorotation System for Live-Cell Microscopy Under Simulated Microgravity

    Science.gov (United States)

    Yew, Alvin G.; Atencia, Javier; Chinn, Ben; Hsieh, Adam H.

    2013-01-01

    Cells in microgravity are subject to mechanical unloading and changes to the surrounding chemical environment. How these factors jointly influence cellular function is not well understood. We can investigate their role using ground-based analogues to spaceflight, where mechanical unloading is simulated through the time-averaged nullification of gravity. The prevailing method for cellular microgravity simulation is to use fluid-filled containers called clinostats. However, conventional clinostats are not designed for temporally tracking cell response, nor are they able to establish dynamic fluid environments. To address these needs, we developed a Clinorotation Time-lapse Microscopy (CTM) system that accommodates lab-on- chip cell culture devices for visualizing time-dependent alterations to cellular behavior. For the purpose of demonstrating CTM, we present preliminary results showing time-dependent differences in cell area between human mesenchymal stem cells (hMSCs) under modeled microgravity and normal gravity.

  14. Distribution and time course of corticosterone excretion in faeces and urine of female mice with varying systemic concentrations

    DEFF Research Database (Denmark)

    Kalliokoski, Otto; Hau, Jann; Jacobsen, Kirsten R

    2010-01-01

    distribution and time course of corticosterone excretion, after intravenous injection of varying corticosterone concentrations, was investigated in female mice. Female BALB/c mice excreted 60% of all corticosterone in the urine with an approximate delay of 5h from tail vein administration. The remaining 40......% were excreted in faeces, with an approximate delay of 9h from administration. The faecal/urinary excretion ratio, as well as time course of excretion, remained unaltered by administration of various doses of corticosterone covering the entire physiological range of serum corticosterone. Although...

  15. Pink urine syndrome

    Directory of Open Access Journals (Sweden)

    Luis del Carpio-Orantes

    2017-03-01

    Full Text Available In the present images we allude to a syndrome of low incidence, characterized by pink urine, being related to factors such as obesity, and being triggered by abdominal surgeries, use of propofol, among others. Being favoured by the presence of abundant crystals of uric acid in the urine confers the typical pink coloration.

  16. Murine Automated Urine Sampler (MAUS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines planned development for a low-power, low-mass automated urine sample collection and preservation system for small mammals, capable of...

  17. Low-cost motility tracking system (LOCOMOTIS for time-lapse microscopy applications and cell visualisation.

    Directory of Open Access Journals (Sweden)

    Adam E Lynch

    Full Text Available Direct visualisation of cells for the purpose of studying their motility has typically required expensive microscopy equipment. However, recent advances in digital sensors mean that it is now possible to image cells for a fraction of the price of a standard microscope. Along with low-cost imaging there has also been a large increase in the availability of high quality, open-source analysis programs. In this study we describe the development and performance of an expandable cell motility system employing inexpensive, commercially available digital USB microscopes to image various cell types using time-lapse and perform tracking assays in proof-of-concept experiments. With this system we were able to measure and record three separate assays simultaneously on one personal computer using identical microscopes, and obtained tracking results comparable in quality to those from other studies that used standard, more expensive, equipment. The microscopes used in our system were capable of a maximum magnification of 413.6×. Although resolution was lower than that of a standard inverted microscope we found this difference to be indistinguishable at the magnification chosen for cell tracking experiments (206.8×. In preliminary cell culture experiments using our system, velocities (mean µm/min ± SE of 0.81 ± 0.01 (Biomphalaria glabrata hemocytes on uncoated plates, 1.17 ± 0.004 (MDA-MB-231 breast cancer cells, 1.24 ± 0.006 (SC5 mouse Sertoli cells and 2.21 ± 0.01 (B. glabrata hemocytes on Poly-L-Lysine coated plates, were measured and are consistent with previous reports. We believe that this system, coupled with open-source analysis software, demonstrates that higher throughput time-lapse imaging of cells for the purpose of studying motility can be an affordable option for all researchers.

  18. Low-cost motility tracking system (LOCOMOTIS) for time-lapse microscopy applications and cell visualisation.

    Science.gov (United States)

    Lynch, Adam E; Triajianto, Junian; Routledge, Edwin

    2014-01-01

    Direct visualisation of cells for the purpose of studying their motility has typically required expensive microscopy equipment. However, recent advances in digital sensors mean that it is now possible to image cells for a fraction of the price of a standard microscope. Along with low-cost imaging there has also been a large increase in the availability of high quality, open-source analysis programs. In this study we describe the development and performance of an expandable cell motility system employing inexpensive, commercially available digital USB microscopes to image various cell types using time-lapse and perform tracking assays in proof-of-concept experiments. With this system we were able to measure and record three separate assays simultaneously on one personal computer using identical microscopes, and obtained tracking results comparable in quality to those from other studies that used standard, more expensive, equipment. The microscopes used in our system were capable of a maximum magnification of 413.6×. Although resolution was lower than that of a standard inverted microscope we found this difference to be indistinguishable at the magnification chosen for cell tracking experiments (206.8×). In preliminary cell culture experiments using our system, velocities (mean µm/min ± SE) of 0.81 ± 0.01 (Biomphalaria glabrata hemocytes on uncoated plates), 1.17 ± 0.004 (MDA-MB-231 breast cancer cells), 1.24 ± 0.006 (SC5 mouse Sertoli cells) and 2.21 ± 0.01 (B. glabrata hemocytes on Poly-L-Lysine coated plates), were measured and are consistent with previous reports. We believe that this system, coupled with open-source analysis software, demonstrates that higher throughput time-lapse imaging of cells for the purpose of studying motility can be an affordable option for all researchers.

  19. Low-Cost Motility Tracking System (LOCOMOTIS) for Time-Lapse Microscopy Applications and Cell Visualisation

    Science.gov (United States)

    Lynch, Adam E.; Triajianto, Junian; Routledge, Edwin

    2014-01-01

    Direct visualisation of cells for the purpose of studying their motility has typically required expensive microscopy equipment. However, recent advances in digital sensors mean that it is now possible to image cells for a fraction of the price of a standard microscope. Along with low-cost imaging there has also been a large increase in the availability of high quality, open-source analysis programs. In this study we describe the development and performance of an expandable cell motility system employing inexpensive, commercially available digital USB microscopes to image various cell types using time-lapse and perform tracking assays in proof-of-concept experiments. With this system we were able to measure and record three separate assays simultaneously on one personal computer using identical microscopes, and obtained tracking results comparable in quality to those from other studies that used standard, more expensive, equipment. The microscopes used in our system were capable of a maximum magnification of 413.6×. Although resolution was lower than that of a standard inverted microscope we found this difference to be indistinguishable at the magnification chosen for cell tracking experiments (206.8×). In preliminary cell culture experiments using our system, velocities (mean µm/min ± SE) of 0.81±0.01 (Biomphalaria glabrata hemocytes on uncoated plates), 1.17±0.004 (MDA-MB-231 breast cancer cells), 1.24±0.006 (SC5 mouse Sertoli cells) and 2.21±0.01 (B. glabrata hemocytes on Poly-L-Lysine coated plates), were measured and are consistent with previous reports. We believe that this system, coupled with open-source analysis software, demonstrates that higher throughput time-lapse imaging of cells for the purpose of studying motility can be an affordable option for all researchers. PMID:25121722

  20. Emissies uit een vleesvarkensstal voorzien van een V-vormige mestband voor het gescheiden afvoeren van mest en urine = Emissions from a housing system for fattening pigs with a V-shaped manure belt for separated removal of faeces and urine

    NARCIS (Netherlands)

    Ellen, H.H.; Hol, J.M.G.; Mosquera, J.; Aarnink, A.J.A.

    2013-01-01

    This study reports the emissions of ammonia, odour, fine dust (PM10 and PM2.5), methane and nitrous oxide from an animal house for fattening pigs provided with V-shaped manure belts for separated removal of faeces and urine (the Kempfarm system).

  1. Local imaging of high mobility two-dimensional electron systems with virtual scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Pelliccione, M. [Department of Applied Physics, Stanford University, 348 Via Pueblo Mall, Stanford, California 94305 (United States); Stanford Institute for Materials and Energy Sciences, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Physics, University of California, Santa Barbara, Santa Barbara, California 93106 (United States); Bartel, J.; Goldhaber-Gordon, D. [Stanford Institute for Materials and Energy Sciences, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Physics, Stanford University, 382 Via Pueblo Mall, Stanford, California 94305 (United States); Sciambi, A. [Department of Applied Physics, Stanford University, 348 Via Pueblo Mall, Stanford, California 94305 (United States); Stanford Institute for Materials and Energy Sciences, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Pfeiffer, L. N.; West, K. W. [Department of Electrical Engineering, Princeton University, Princeton, New Jersey 08544 (United States)

    2014-11-03

    Correlated electron states in high mobility two-dimensional electron systems (2DESs), including charge density waves and microemulsion phases intermediate between a Fermi liquid and Wigner crystal, are predicted to exhibit complex local charge order. Existing experimental studies, however, have mainly probed these systems at micron to millimeter scales rather than directly mapping spatial organization. Scanning probes should be well-suited to study the spatial structure of these states, but high mobility 2DESs are found at buried semiconductor interfaces, beyond the reach of conventional scanning tunneling microscopy. Scanning techniques based on electrostatic coupling to the 2DES deliver important insights, but generally with resolution limited by the depth of the 2DES. In this letter, we present our progress in developing a technique called “virtual scanning tunneling microscopy” that allows local tunneling into a high mobility 2DES. Using a specially designed bilayer GaAs/AlGaAs heterostructure where the tunnel coupling between two separate 2DESs is tunable via electrostatic gating, combined with a scanning gate, we show that the local tunneling can be controlled with sub-250 nm resolution.

  2. Life cycle comparison of centralized wastewater treatment and urine source separation with struvite precipitation: Focus on urine nutrient management.

    Science.gov (United States)

    Ishii, Stephanie K L; Boyer, Treavor H

    2015-08-01

    Alternative approaches to wastewater management including urine source separation have the potential to simultaneously improve multiple aspects of wastewater treatment, including reduced use of potable water for waste conveyance and improved contaminant removal, especially nutrients. In order to pursue such radical changes, system-level evaluations of urine source separation in community contexts are required. The focus of this life cycle assessment (LCA) is managing nutrients from urine produced in a residential setting with urine source separation and struvite precipitation, as compared with a centralized wastewater treatment approach. The life cycle impacts evaluated in this study pertain to construction of the urine source separation system and operation of drinking water treatment, decentralized urine treatment, and centralized wastewater treatment. System boundaries include fertilizer offsets resulting from the production of urine based struvite fertilizer. As calculated by the Tool for the Reduction and Assessment of Chemical and Other Environmental Impacts (TRACI), urine source separation with MgO addition for subsequent struvite precipitation with high P recovery (Scenario B) has the smallest environmental cost relative to existing centralized wastewater treatment (Scenario A) and urine source separation with MgO and Na3PO4 addition for subsequent struvite precipitation with concurrent high P and N recovery (Scenario C). Preliminary economic evaluations show that the three urine management scenarios are relatively equal on a monetary basis (<13% difference). The impacts of each urine management scenario are most sensitive to the assumed urine composition, the selected urine storage time, and the assumed electricity required to treat influent urine and toilet water used to convey urine at the centralized wastewater treatment plant. The importance of full nutrient recovery from urine in combination with the substantial chemical inputs required for N recovery

  3. Chemical Method of Urine Volume Measurement

    Science.gov (United States)

    Petrack, P.

    1967-01-01

    A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

  4. Creatinine urine test

    Science.gov (United States)

    Urine creatinine test ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ... done to see how well your kidneys work. Creatinine is removed by the body entirely by the ...

  5. Urine protein electrophoresis test

    Science.gov (United States)

    Urine protein electrophoresis; UPEP; Multiple myeloma - UPEP; Waldenström macroglobulinemia - UPEP; Amyloidosis - UPEP ... special paper and apply an electric current. The proteins move and form visible bands. These reveal the ...

  6. Uric acid - urine

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003616.htm Uric acid urine test To use the sharing features on ... are no risks with this test. Images Uric acid test Uric acid crystals References Burns CM, Wortmann RL. Clinical ...

  7. Purple Urine Bag Syndrome

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    sudden onset, progressive left sided weakness involving both upper and ... computed tomography of the brain showed right ... included a complete blood count, renal functions which were ... Urine culture had a significant growth of Klebsiella.

  8. Bacteria as a new model system for aging studies: investigations using light microscopy.

    Science.gov (United States)

    Ackermann, Martin

    2008-04-01

    Aging-the decline in an individual's condition over time-is at the center of an active research field in medicine and biology. Some very basic questions have, however, remained unresolved, the most fundamental being: do all organisms age? Or are there organisms that would continue to live forever if not killed by external forces? For a long time it was believed that aging only affected organisms such as animals, plants, and fungi. Bacteria, in contrast, were assumed to be potentially immortal and until recently this assertion remained untested. We used phase-contrast microscopy (on an Olympus BX61) to follow individual bacterial cells over many divisions to prove that some bacteria show a distinction between an aging mother cell and a rejuvenated daughter, and that these bacteria thus age. This indicates that aging is a more fundamental property of organisms than was previously assumed. Bacteria can now be used as very simple model system for investigating why and how organisms age.

  9. Ultra-Broadband Two-Dimensional Electronic Spectroscopy and Pump-Probe Microscopy of Molecular Systems

    Science.gov (United States)

    Spokoyny, Boris M.

    Ultrafast spectroscopy offers an unprecedented view on the dynamic nature of chemical reactions. From charge transfer in semiconductors to folding and isomerization of proteins, these all important processes can now be monitored and in some instances even controlled on real, physical timescales. One of the biggest challenges of ultrafast science is the incredible energetic complexity of most systems. It is not uncommon to encounter macromolecules or materials with absorption spectra spanning significant portions of the visible spectrum. Monitoring a multitude of electronic and vibrational transitions, all dynamically interacting with each other on femtosecond timescales poses a truly daunting experimental task. The first part of this thesis deals with the development of a novel Two-Dimensional Electronic Spectroscopy (2DES) and its associated, advanced detection methodologies. Owing to its ultra-broadband implementation, this technique enables us to monitor femtosecond chemical dynamics that span the energetic landscape of the entire visible spectrum. In order to demonstrate the utility of our method, we apply it to two laser dye molecules, IR-144 and Cresyl Violet. Variation of photophysical properties on a microscopic scale in either man-made or naturally occurring systems can have profound implications on how we understand their macroscopic properties. Recently, inorganic hybrid perovskites have been tapped as the next generation solar energy harvesting materials. Their remarkable properties include low exciton binding energy, low exciton recombination rates and long carrier diffusion lengths. Nevertheless, considerable variability in device properties made with nearly identical preparation methods has puzzled the community. In the second part of this thesis we use non-linear pump probe microscopy to study the heterogeneous nature of femtosecond carrier dynamics in thin film perovskites. We show that the local morphology of the perovskite thin films has a

  10. Low cost automated whole smear microscopy screening system for detection of acid fast bacilli.

    Directory of Open Access Journals (Sweden)

    Yan Nei Law

    Full Text Available In countries with high tuberculosis (TB burden, there is urgent need for rapid, large-scale screening to detect smear-positive patients. We developed a computer-aided whole smear screening system that focuses in real-time, captures images and provides diagnostic grading, for both bright-field and fluorescence microscopy for detection of acid-fast-bacilli (AFB from respiratory specimens.To evaluate the performance of dual-mode screening system in AFB diagnostic algorithms on concentrated smears with auramine O (AO staining, as well as direct smears with AO and Ziehl-Neelsen (ZN staining, using mycobacterial culture results as gold standard.Adult patient sputum samples requesting for M. tuberculosis cultures were divided into three batches for staining: direct AO-stained, direct ZN-stained and concentrated smears AO-stained. All slides were graded by an experienced microscopist, in parallel with the automated whole smear screening system. Sensitivity and specificity of a TB diagnostic algorithm in using the screening system alone, and in combination with a microscopist, were evaluated.Of 488 direct AO-stained smears, 228 were culture positive. These yielded a sensitivity of 81.6% and specificity of 74.2%. Of 334 direct smears with ZN staining, 142 were culture positive, which gave a sensitivity of 70.4% and specificity of 76.6%. Of 505 concentrated smears with AO staining, 250 were culture positive, giving a sensitivity of 86.4% and specificity of 71.0%. To further improve performance, machine grading was confirmed by manual smear grading when the number of AFBs detected fell within an uncertainty range. These combined results gave significant improvement in specificity (AO-direct:85.4%; ZN-direct:85.4%; AO-concentrated:92.5% and slight improvement in sensitivity while requiring only limited manual workload.Our system achieved high sensitivity without substantially compromising specificity when compared to culture results. Significant improvement

  11. The neuromuscular system of Pycnophyes kielensis (Kinorhyncha: Allomalorhagida) investigated by confocal laser scanning microscopy.

    Science.gov (United States)

    Altenburger, Andreas

    2016-01-01

    Kinorhynchs are ecdysozoan animals with a phylogenetic position close to priapulids and loriciferans. To understand the nature of segmentation within Kinorhyncha and to infer a probable ancestry of segmentation within the last common ancestor of Ecdysozoa, the musculature and the nervous system of the allomalorhagid kinorhynch Pycnophyes kielensis were investigated by use of immunohistochemistry, confocal laser scanning microscopy, and 3D reconstruction software. The kinorhynch body plan comprises 11 trunk segments. Trunk musculature consists of paired ventral and dorsal longitudinal muscles in segments 1-10 as well as dorsoventral muscles in segments 1-11. Dorsal and ventral longitudinal muscles insert on apodemes of the cuticle inside the animal within each segment. Strands of longitudinal musculature extend over segment borders in segments 1-6. In segments 7-10, the trunk musculature is confined to the segments. Musculature of the digestive system comprises a strong pharyngeal bulb with attached mouth cone muscles as well as pharyngeal bulb protractors and retractors. The musculature of the digestive system shows no sign of segmentation. Judged by the size of the pharyngeal bulb protractors and retractors, the pharyngeal bulb, as well as the introvert, is moved passively by internal pressure caused by concerted action of the dorsoventral muscles. The nervous system comprises a neuropil ring anterior to the pharyngeal bulb. Associated with the neuropil ring are flask-shaped serotonergic somata extending anteriorly and posteriorly. A ventral nerve cord is connected to the neuropil ring and runs toward the anterior until an attachment point in segment 1, and from there toward the posterior with one ganglion in segment 6. Segmentation within Kinorhyncha likely evolved from an unsegmented ancestor. This conclusion is supported by continuous trunk musculature in the anterior segments 1-6, continuous pharyngeal bulb protractors and retractors throughout the anterior

  12. The neuromuscular system of Pycnophyes kielensis (Kinorhyncha: Allomalorhagida investigated by confocal laser scanning microscopy

    Directory of Open Access Journals (Sweden)

    Andreas Altenburger

    2016-11-01

    Full Text Available Abstract Background Kinorhynchs are ecdysozoan animals with a phylogenetic position close to priapulids and loriciferans. To understand the nature of segmentation within Kinorhyncha and to infer a probable ancestry of segmentation within the last common ancestor of Ecdysozoa, the musculature and the nervous system of the allomalorhagid kinorhynch Pycnophyes kielensis were investigated by use of immunohistochemistry, confocal laser scanning microscopy, and 3D reconstruction software. Results The kinorhynch body plan comprises 11 trunk segments. Trunk musculature consists of paired ventral and dorsal longitudinal muscles in segments 1–10 as well as dorsoventral muscles in segments 1–11. Dorsal and ventral longitudinal muscles insert on apodemes of the cuticle inside the animal within each segment. Strands of longitudinal musculature extend over segment borders in segments 1–6. In segments 7–10, the trunk musculature is confined to the segments. Musculature of the digestive system comprises a strong pharyngeal bulb with attached mouth cone muscles as well as pharyngeal bulb protractors and retractors. The musculature of the digestive system shows no sign of segmentation. Judged by the size of the pharyngeal bulb protractors and retractors, the pharyngeal bulb, as well as the introvert, is moved passively by internal pressure caused by concerted action of the dorsoventral muscles. The nervous system comprises a neuropil ring anterior to the pharyngeal bulb. Associated with the neuropil ring are flask-shaped serotonergic somata extending anteriorly and posteriorly. A ventral nerve cord is connected to the neuropil ring and runs toward the anterior until an attachment point in segment 1, and from there toward the posterior with one ganglion in segment 6. Conclusions Segmentation within Kinorhyncha likely evolved from an unsegmented ancestor. This conclusion is supported by continuous trunk musculature in the anterior segments 1–6, continuous

  13. Fluorescence microscopy.

    Science.gov (United States)

    Sanderson, Michael J; Smith, Ian; Parker, Ian; Bootman, Martin D

    2014-10-01

    Fluorescence microscopy is a major tool with which to monitor cell physiology. Although the concepts of fluorescence and its optical separation using filters remain similar, microscope design varies with the aim of increasing image contrast and spatial resolution. The basics of wide-field microscopy are outlined to emphasize the selection, advantages, and correct use of laser scanning confocal microscopy, two-photon microscopy, scanning disk confocal microscopy, total internal reflection, and super-resolution microscopy. In addition, the principles of how these microscopes form images are reviewed to appreciate their capabilities, limitations, and constraints for operation. © 2014 Cold Spring Harbor Laboratory Press.

  14. Occurrence of riboflavinyl glucoside in rat urine

    International Nuclear Information System (INIS)

    Ohkawa, Hiroshi; Ohishi, Nobuko; Yagi, Kunio

    1983-01-01

    To investigate the metabolism of riboflavin, [2- 14 C]-riboflavin was administered orally to a rat. The urine pooled for 24 h after administration was fractionated by paper and silica gel thin layer chromatographies using various solvent systems. Among the radioactive metabolites, riboflavinyl glucoside was found along with 7-carboxy lumichrome and 8-carboxy lumichrome. The radioactivity of riboflavinyl glucoside comprised about 6 % of the total radioactivity excreted in the urine during 24 h. (author)

  15. Applications of atomic force microscopy to the studies of biomaterials in biomolecular systems

    Science.gov (United States)

    Ma, Xiang

    Atomic force microscopy (AFM) is a unique tool for the studies of nanoscale structures and interactions. In this dissertation, I applied AFM to study transitions among multiple states of biomaterials in three different microscopic biomolecular systems: MukB-dependent DNA condensation, holdfast adhesion, and virus elasticity. To elucidate the mechanism of MukB-dependent DNA condensation, I have studied the conformational changes of MukB proteins as indicators for the strength of interactions between MukB, DNA and other molecular factors, such as magnesium and ParC proteins, using high-resolution AFM imaging. To determine the physical origins of holdfast adhesion, I have investigated the dynamics of adhesive force development of the holdfast, employing AFM force spectroscopy. By measuring rupture forces between the holdfast and the substrate, I showed that the holdfast adhesion is strongly time-dependent and involves transformations at multiple time scales. Understanding the mechanisms of adhesion force development of the holdfast will be critical for future engineering of holdfasts properties for various applications. Finally, I have examined the elasticity of self-assembled hepatitis B virus-like particles (HBV VLPs) and brome mosaic virus (BMV) in response to changes of pH and salinity, using AFM nanoindentation. The distributions of elasticity were mapped on a single particle level and compared between empty, RNA- and gold-filled HBV VLPs. I found that a single HBV VLP showed heterogeneous distribution of elasticity and a two-step buckling transition, suggesting a discrete property of HBV capsids. For BMV, I have showed that viruses containing different RNA molecules can be distinguished by mechanical measurements, while they are indistinguishable by morphology. I also studied the effect of pH on the elastic behaviors of three-particle BMV and R3/4 BMV. This study can yield insights into RNA presentation/release mechanisms, and could help us to design novel drug

  16. Urine Concentration and Pyuria for Identifying UTI in Infants.

    Science.gov (United States)

    Chaudhari, Pradip P; Monuteaux, Michael C; Bachur, Richard G

    2016-11-01

    Varying urine white blood cell (WBC) thresholds have been recommended for the presumptive diagnosis of urinary tract infection (UTI) among young infants. These thresholds have not been studied with newer automated urinalysis systems that analyze uncentrifuged urine that might be influenced by urine concentration. Our objective was to determine the optimal urine WBC threshold for UTI in young infants by using an automated urinalysis system, stratified by urine concentration. Retrospective cross-sectional study of infants aged UTI in the emergency department with paired urinalysis and urine culture. UTI was defined as ≥50 000 colony-forming units/mL from catheterized specimens. Test characteristics were calculated across a range of WBC and leukocyte esterase (LE) cut-points, dichotomized into specific gravity groups (dilute UTI prevalence was 7.8%. Optimal WBC cut-points were 3 WBC/high-power field (HPF) in dilute urine (likelihood ratio positive [LR+] 9.9, likelihood ratio negative [LR‒] 0.15) and 6 WBC/HPF (LR+ 10.1, LR‒ 0.17) in concentrated urine. For dipstick analysis, positive LE has excellent test characteristics regardless of urine concentration (LR+ 22.1, LR‒ 0.12 in dilute urine; LR+ 31.6, LR‒ 0.22 in concentrated urine). Urine concentration should be incorporated into the interpretation of automated microscopic urinalysis in young infants. Pyuria thresholds of 3 WBC/HPF in dilute urine and 6 WBC/HPF in concentrated urine are recommended for the presumptive diagnosis of UTI. Without correction of specific gravity, positive LE by automated dipstick is a reliably strong indicator of UTI. Copyright © 2016 by the American Academy of Pediatrics.

  17. The Human Urine Metabolome

    Science.gov (United States)

    Bouatra, Souhaila; Aziat, Farid; Mandal, Rupasri; Guo, An Chi; Wilson, Michael R.; Knox, Craig; Bjorndahl, Trent C.; Krishnamurthy, Ramanarayan; Saleem, Fozia; Liu, Philip; Dame, Zerihun T.; Poelzer, Jenna; Huynh, Jessica; Yallou, Faizath S.; Psychogios, Nick; Dong, Edison; Bogumil, Ralf; Roehring, Cornelia; Wishart, David S.

    2013-01-01

    Urine has long been a “favored” biofluid among metabolomics researchers. It is sterile, easy-to-obtain in large volumes, largely free from interfering proteins or lipids and chemically complex. However, this chemical complexity has also made urine a particularly difficult substrate to fully understand. As a biological waste material, urine typically contains metabolic breakdown products from a wide range of foods, drinks, drugs, environmental contaminants, endogenous waste metabolites and bacterial by-products. Many of these compounds are poorly characterized and poorly understood. In an effort to improve our understanding of this biofluid we have undertaken a comprehensive, quantitative, metabolome-wide characterization of human urine. This involved both computer-aided literature mining and comprehensive, quantitative experimental assessment/validation. The experimental portion employed NMR spectroscopy, gas chromatography mass spectrometry (GC-MS), direct flow injection mass spectrometry (DFI/LC-MS/MS), inductively coupled plasma mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) experiments performed on multiple human urine samples. This multi-platform metabolomic analysis allowed us to identify 445 and quantify 378 unique urine metabolites or metabolite species. The different analytical platforms were able to identify (quantify) a total of: 209 (209) by NMR, 179 (85) by GC-MS, 127 (127) by DFI/LC-MS/MS, 40 (40) by ICP-MS and 10 (10) by HPLC. Our use of multiple metabolomics platforms and technologies allowed us to identify several previously unknown urine metabolites and to substantially enhance the level of metabolome coverage. It also allowed us to critically assess the relative strengths and weaknesses of different platforms or technologies. The literature review led to the identification and annotation of another 2206 urinary compounds and was used to help guide the subsequent experimental studies. An online database containing

  18. Analytical electron microscopy investigation of the AlN-ZrO2 system

    International Nuclear Information System (INIS)

    Stoto, T.; Doukhan, J.C.; Mocellin, A.

    1989-01-01

    A combination of electron microscopy, diffraction, and spectroscopic techniques were used to identify and characterize the quaternary Zr-Al-O-N phase, which forms during reaction sintering of AIN + ZrO 2 mixtures. In this paper it is proposed that this phase has a space group Fd 3 m; several compositions are suggested

  19. A Versatile High-Vacuum Cryo-transfer System for Cryo-microscopy and Analytics

    Czech Academy of Sciences Publication Activity Database

    Tacke, S.; Krzyžánek, Vladislav; Nüsse, H.; Wepf, R.A.; Klingauf, J.; Reichelt, R.

    2016-01-01

    Roč. 110, č. 4 (2016), s. 758-765 ISSN 0006-3495 R&D Projects: GA ČR(CZ) GA14-20012S Institutional support: RVO:68081731 Keywords : transmission electron microscopy * cryoelectron tomography * cells Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.656, year: 2016

  20. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: FOUNDATIONS FOR QUANTIFYING CYTOMETRIC APPLICATIONS WITH SPECTROSCOPIC INSTRUMENTS

    Science.gov (United States)

    The confocal laser-scanning microscopy (CLSM) has enormous potential in many biological fields. The goal of a CLSM is to acquire and quantify fluorescence and in some instruments acquire spectral characterization of the emitted signal. The accuracy of these measurements demands t...

  1. Mutagens in urine of carbon electrode workers

    Energy Technology Data Exchange (ETDEWEB)

    Pasquini, R; Monarca, S; Sforzolini, G S; Conti, R; Fagioli, F

    1982-01-01

    Following previous work carried out in an Italian factory producing carbon electrodes and evaluating the occupational mutagenic-carcinogenic hazards, the authors studied the presence of mutagen metabolites in the urine of workers in the same factory who were exposed to petroleum coke and pitch and in the urine of a control group of unexposed workers. The urine samples were concentrated by absorption on XAD-2 columns and were tested using the Salmonella/microsome assay (strain TA98, TA100, TA1535, TA1538) with and without the addition of beta-glucuronidase and metabolizing system. The collection of urine samples was carried out twice, with an interval of 2 months; 'before working time', 'after working time', and also during Sunday. The results showed that urine samples collected 'before' occupational exposure (upon waking) or on Sunday revealed no mutagenic activity in either worker groups and that the urine samples collected after or during occupational exposure revealed high mutagenic activity in the exposed workers, with a statistically significant difference between the mean of the revertants/plate values for exposed and unexposed workers. On the basis of the previous and the present research, the authors suggest that application of the Salmonella/microsome test to work environments could offer useful and suitable tool for evaluating the health hazards due to mutagenic/carcinogenic substances from occupational exposure.

  2. 24-hour urine protein

    Science.gov (United States)

    ... your provider may be able to order a test that is done on just one urine sample (protein-to-creatinine ratio). Normal Results The normal ... Some labs use different measurements or test different samples. Talk to your provider about the meaning of your specific test ... Abnormal results may be due to: A group ...

  3. Citric acid urine test

    Science.gov (United States)

    Urine - citric acid test; Renal tubular acidosis - citric acid test; Kidney stones - citric acid test; Urolithiasis - citric acid test ... No special preparation is necessary for this test. But the results ... test is usually done while you are on a normal diet. Ask your ...

  4. Automated color classification of urine dipstick image in urine examination

    Science.gov (United States)

    Rahmat, R. F.; Royananda; Muchtar, M. A.; Taqiuddin, R.; Adnan, S.; Anugrahwaty, R.; Budiarto, R.

    2018-03-01

    Urine examination using urine dipstick has long been used to determine the health status of a person. The economical and convenient use of urine dipstick is one of the reasons urine dipstick is still used to check people health status. The real-life implementation of urine dipstick is done manually, in general, that is by comparing it with the reference color visually. This resulted perception differences in the color reading of the examination results. In this research, authors used a scanner to obtain the urine dipstick color image. The use of scanner can be one of the solutions in reading the result of urine dipstick because the light produced is consistent. A method is required to overcome the problems of urine dipstick color matching and the test reference color that have been conducted manually. The method proposed by authors is Euclidean Distance, Otsu along with RGB color feature extraction method to match the colors on the urine dipstick with the standard reference color of urine examination. The result shows that the proposed approach was able to classify the colors on a urine dipstick with an accuracy of 95.45%. The accuracy of color classification on urine dipstick against the standard reference color is influenced by the level of scanner resolution used, the higher the scanner resolution level, the higher the accuracy.

  5. Scanning Electron Microscopy of Nonconductive Specimens at Critical Energies in a Cathode Lens System

    Czech Academy of Sciences Publication Activity Database

    Frank, Luděk; Zadražil, Martin; Müllerová, Ilona

    2001-01-01

    Roč. 23, č. 1 (2001), s. 36-50 ISSN 0161-0457 R&D Projects: GA ČR GA202/96/0961; GA ČR GA202/99/0008 Institutional research plan: CEZ:AV0Z2065902 Keywords : scanning electron microscopy * specimen charging * nonconductive specimens Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.389, year: 2001

  6. Photo-induced processes in collagen-hypericin system revealed by fluorescence spectroscopy and multiphoton microscopy

    OpenAIRE

    Hovhannisyan, V.; Guo, H. W.; Hovhannisyan, A.; Ghukasyan, V.; Buryakina, T.; Chen, Y. F.; Dong, C. Y.

    2014-01-01

    Collagen is the main structural protein and the key determinant of mechanical and functional properties of tissues and organs. Proper balance between synthesis and degradation of collagen molecules is critical for maintaining normal physiological functions. In addition, collagen influences tumor development and drug delivery, which makes it a potential cancer therapy target. Using second harmonic generation, two-photon excited fluorescence microscopy, and spectrofluorimetry, we show that the ...

  7. Investigation on a Sensitive Chemiluminescence System Based on Ni(IV Complex to Determine Two β2-Agonist Drugs in Urine and Swine Feed and Their Mechanism

    Directory of Open Access Journals (Sweden)

    Xiao Dong

    2018-04-01

    Full Text Available Veterinary drug residues, particularly traces of β2-agonists, can cause various kinds of harmful impact to the environment and public health. Here, a sensitive chemiluminescence (CL method incorporated with a flow injection analysis is developed for the determination of two β2-agonists [i.e., salbutamol (SAL and terbutaline (TEB]. The system is based on the CL reaction of Ni(IV complex with luminol in alkaline solutions, whereas SAL and TEB can significantly enhance CL intensities. Under optimum conditions, CL intensities are proportional to the SAL and TEB concentration in the range of 1.0 × 10−9 M to 5.0 × 10−7 M and 1.0 × 10−9 M to 1.0 × 10−7 M, respectively. The limits of detection (3σ are 1.0 × 10−11 M for TEB, and 1.3 × 10−11 for SAL respectively. Relative standard deviations (n = 11 are less than 2% for 5.0 × 10−8 M SAL and TEB. Possible reaction mechanisms for the CL system are suggested based on the CL system spectra, Ni(IV complex oxidation characteristics, and electron spin resonance (ESR techniques. The proposed method has been applied to the analysis of urine and swine feed samples with satisfactory results.

  8. Urine pH test

    Science.gov (United States)

    ... urine test Male urinary tract References Bose A, Monk RD, Bushinsky DA. Kidney stones. In: Melmed S, Polonsky ... and its influence on urine pH. J Am Diet Assoc . 1995;95(7):791-797. PMID: 7797810 ...

  9. Changes in urine composition after trauma facilitate bacterial growth

    Directory of Open Access Journals (Sweden)

    Aubron Cecile

    2012-11-01

    Full Text Available Abstract Background Critically ill patients including trauma patients are at high risk of urinary tract infection (UTI. The composition of urine in trauma patients may be modified due to inflammation, systemic stress, rhabdomyolysis, life support treatment and/or urinary catheter insertion. Methods Prospective, single-centre, observational study conducted in patients with severe trauma and without a history of UTIs or recent antibiotic treatment. The 24-hour urine samples were collected on the first and the fifth days and the growth of Escherichia coli in urine from patients and healthy volunteers was compared. Biochemical and hormonal modifications in urine that could potentially influence bacterial growth were explored. Results Growth of E. coli in urine from trauma patients was significantly higher on days 1 and 5 than in urine of healthy volunteers. Several significant modifications of urine composition could explain these findings. On days 1 and 5, trauma patients had an increase in glycosuria, in urine iron concentration, and in the concentrations of several amino acids compared to healthy volunteers. On day 1, the urinary osmotic pressure was significantly lower than for healthy volunteers. Conclusion We showed that urine of trauma patients facilitated growth of E. coli when compared to urine from healthy volunteers. This effect was present in the first 24 hours and until at least the fifth day after trauma. This phenomenon may be involved in the pathophysiology of UTIs in trauma patients. Further studies are required to define the exact causes of such modifications.

  10. Polythiophenes and fullerene derivatives based donor-acceptor system: topography by atomic force microscopy

    International Nuclear Information System (INIS)

    Marcakova, M. L.; Repovsky, D.; Cik, G.; Velic, D.

    2017-01-01

    The goal of this work is to examine the surface of a polythiophene/fullerene film in order to understand the structure. In this work polythiophene is used as electron donor and fullerene-derivative is used as electron acceptor. Atomic force microscopy (AFM), is an ideal method to study surfaces and nanostructures. Surfaces of fullerene C60 , fullerene-derivates PCBM, polythiophene P12 and a mixture of P12 and PCBM are characterized. In all samples, the average roughness, the arithmetical value of divergence from the high of the surface, is determined concluding that P12 and PCBM mix together well and form a film with specific topography. (authors)

  11. Photo-induced processes in collagen-hypericin system revealed by fluorescence spectroscopy and multiphoton microscopy.

    Science.gov (United States)

    Hovhannisyan, V; Guo, H W; Hovhannisyan, A; Ghukasyan, V; Buryakina, T; Chen, Y F; Dong, C Y

    2014-05-01

    Collagen is the main structural protein and the key determinant of mechanical and functional properties of tissues and organs. Proper balance between synthesis and degradation of collagen molecules is critical for maintaining normal physiological functions. In addition, collagen influences tumor development and drug delivery, which makes it a potential cancer therapy target. Using second harmonic generation, two-photon excited fluorescence microscopy, and spectrofluorimetry, we show that the natural pigment hypericin induces photosensitized destruction of collagen-based tissues. We demonstrate that hypericin-mediated processes in collagen fibers are irreversible and may be used for the treatment of cancer and collagen-related disorders.

  12. Light-free magnetic resonance force microscopy for studies of electron spin polarized systems

    International Nuclear Information System (INIS)

    Pelekhov, Denis V.; Selcu, Camelia; Banerjee, Palash; Chung Fong, Kin; Chris Hammel, P.; Bhaskaran, Harish; Schwab, Keith

    2005-01-01

    Magnetic resonance force microscopy is a scanned probe technique capable of three-dimensional magnetic resonance imaging. Its excellent sensitivity opens the possibility for magnetic resonance studies of spin accumulation resulting from the injection of spin polarized currents into a para-magnetic collector. The method is based on mechanical detection of magnetic resonance which requires low noise detection of cantilever displacement; so far, this has been accomplished using optical interferometry. This is undesirable for experiments on doped silicon, where the presence of light is known to enhance spin relaxation rates. We report a non-optical displacement detection scheme based on sensitive microwave capacitive readout

  13. New microscopy for nanoimaging

    CERN Document Server

    Kinjo, Y; Watanabe, M

    2002-01-01

    Two types of new microscopy, namely, X-ray contact microscopy (XRCM) in combination with atomic force microscopy (AFM) and X-ray projection microscopy (XRPM) using synchrotron radiation and zone plate optics were used to image the fine structures of human chromosomes. In the XRCM plus AFM system, location of X-ray images on a photoresist has become far easier than that with our previous method using transmission electron microscopy coupled with the replica method. In addition, the images obtained suggested that the conformation of chromatin fiber differs from the current textbook model regarding the architecture of a eukaryotic chromosome. X-ray images with high contrast of the specimens could be obtained with XRPM. The resolution of each microscopy was about 30 and 200-300 nm for XRCM plus AFM and XRPM, respectively. (author)

  14. Quantitative Analysis of Subcellular Distribution of the SUMO Conjugation System by Confocal Microscopy Imaging.

    Science.gov (United States)

    Mas, Abraham; Amenós, Montse; Lois, L Maria

    2016-01-01

    Different studies point to an enrichment in SUMO conjugation in the cell nucleus, although non-nuclear SUMO targets also exist. In general, the study of subcellular localization of proteins is essential for understanding their function within a cell. Fluorescence microscopy is a powerful tool for studying subcellular protein partitioning in living cells, since fluorescent proteins can be fused to proteins of interest to determine their localization. Subcellular distribution of proteins can be influenced by binding to other biomolecules and by posttranslational modifications. Sometimes these changes affect only a portion of the protein pool or have a partial effect, and a quantitative evaluation of fluorescence images is required to identify protein redistribution among subcellular compartments. In order to obtain accurate data about the relative subcellular distribution of SUMO conjugation machinery members, and to identify the molecular determinants involved in their localization, we have applied quantitative confocal microscopy imaging. In this chapter, we will describe the fluorescent protein fusions used in these experiments, and how to measure, evaluate, and compare average fluorescence intensities in cellular compartments by image-based analysis. We show the distribution of some components of the Arabidopsis SUMOylation machinery in epidermal onion cells and how they change their distribution in the presence of interacting partners or even when its activity is affected.

  15. Confocal microscopy as a useful approach to describe gill rakers of Asian species of carp and native filter-feeding fishes of the upper Mississippi River system

    Science.gov (United States)

    Liza R. Walleser,; D.R. Howard,; Sandheinrich, Mark B.; Gaikowski, Mark P.; Amberg, Jon J.

    2014-01-01

    To better understand potential diet overlap among exotic Asian species of carp and native species of filter-feeding fishes of the upper Mississippi River system, microscopy was used to document morphological differences in the gill rakers. Analysing samples first with light microscopy and subsequently with confocal microscopy, the three-dimensional structure of gill rakers in Hypophthalmichthys molitrix,Hypophthalmichthys nobilis and Dorosoma cepedianum was more thoroughly described and illustrated than previous work with traditional microscopy techniques. The three-dimensional structure of gill rakers in Ictiobus cyprinellus was described and illustrated for the first time.

  16. Electrolytic pretreatment of urine

    Science.gov (United States)

    1977-01-01

    Electrolysis has been under evaluation for several years as a process to pretreat urine for ultimate recovery of potable water in manned spacecraft applications. The conclusions that were drawn from this investigation are the following: (1) A platinum alloy containing 10 percent rhodium has been shown to be an effective, corrosion-resistant anode material for the electrolytic pretreatment of urine. Black platinum has been found to be suitable as a cathode material. (2) The mechanism of the reactions occurring during the electrolysis of urine is two-stage: (a) a total Kjeldahl nitrogen and total organic carbon (TOC) removal in the first stage is the result of electrochemical oxidation of urea to CO2, H2O, and ammonia followed by chloride interaction to produce N2 from ammonia, (b) after the urea has been essentially removed and the chloride ions have no more ammonia to interact with, the chloride ions start to oxidize to higher valence states, thus producing perchlorates. (3) Formation of perchlorates can be suppressed by high/low current operation, elevated temperature, and pH adjustment. (4) UV-radiation showed promise in assisting electrolytic TOC removal in beaker tests, but was not substantiated in limited single cell testing. This may have been due to non-optimum configurations of the single cell test rig and the light source.

  17. Diagnosis efficiency of urine malaria test kit for the diagnosis of ...

    African Journals Online (AJOL)

    The aim of this study was to determine the diagnostic efficiencies of urine malaria test kit with microscopy as the gold standard in detecting Plasmodium falciparum HRP-2, a poly-histidine antigen in urine of febrile patients. The study was conducted in a primary and secondary health institution in Gombe Town, Gombe State, ...

  18. Bacterial Isolates from the Urine of Women in Ilorin and their ...

    African Journals Online (AJOL)

    Bacterial Isolates from the Urine of Women in Ilorin and their Antibiotic Susceptibility Patterns. ... Methods: Urine samples of women suspected to have UTI were sent for microscopy, culture and sensitivity tests. The results were analyzed and the differences between the results of pregnant and non-pregnant patients were ...

  19. Bioassay method for Uranium in urine by Delay Neutron counting

    International Nuclear Information System (INIS)

    Suratman; Purwanto; Sukarman-Aminjoyo

    1996-01-01

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 μg

  20. Highly sensitive trivalent copper chelate–luminol chemiluminescence system for capillary electrophoresis chiral separation and determination of ofloxacin enantiomers in urine samples

    Directory of Open Access Journals (Sweden)

    Hao-Yue Xie

    2014-12-01

    Full Text Available A simple, fast and sensitive capillary electrophoresis (CE strategy combined with chemiluminescence (CL detection for analysis of ofloxacin (OF enantiomers was established in the present work. Sulfonated β-cyclodextrin (β-CD was used as the chiral additive being added into the running buffer of luminol–diperiodatocuprate (III (K5[Cu(HIO62], DPC chemiluminescence system. Under the optimum conditions, the proposed method was successfully applied to separation and analysis of OF enantiomers with the detection limits (S/N=3 of 8.0 nM and 7.0 nM for levofloxacin and dextrofloxacin, respectively. The linear ranges were both 0.010–100 μM. The method was utilized for analyzing OF in urine; the results obtained were satisfactory and recoveries were 89.5–110.8%, which demonstrated the reliability of this method. This approach can also be further extended to analyze different commercial OF medicines. Keywords: Ofloxacin, Chiral analysis, Sulfonated-β-CD, Capillary electrophoresis, Chemiluminescence

  1. Molecularly imprinted polymer based quartz crystal microbalance sensor system for sensitive and label-free detection of synthetic cannabinoids in urine.

    Science.gov (United States)

    Battal, Dilek; Akgönüllü, Semra; Yalcin, M Serkan; Yavuz, Handan; Denizli, Adil

    2018-07-15

    Herein, we prepared a novel quartz crystal microbalance (QCM) sensor for synthetic cannabinoids (JWH-073, JWH-073 butanoic acid, JWH-018 and JWH-018 pentanoic acid,) detection. Firstly, the synthetic cannabinoid (SCs) imprinted (MIP) and non-imprinted (NIP) nanoparticles were synthesized by mini-emulsion polymerization system. The SCs-imprinted nanoparticles were first characterized by SEM, TEM, zeta-size and FTIR-ATR analysis and then were dropped onto the gold QCM surface. The SCs-imprinted QCM sensor was characterized by an ellipsometer, contact angle, and AFM. The limit of detection was found as 0.3, 0.45, 0.4, 0.2 pg/mL JWH-018, JWH-073, JWH-018 pentanoic acid and JWH-073 butanoic acid, respectively. The selectivity of the SCs-imprinted QCM sensor was shown by using JWH-018, JWH-018 pentanoic acid, JWH-073 and JWH-073 butanoic acid. According to the results, the SCs-imprinted QCM sensors show highly selective and sensitive in a broad range of synthetic cannabinoid concentrations (0.0005-1.0 ng/mL) in both aqueous and synthetic urine solutions. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Glycogen in the Nervous System. I; Methods for Light and Electron Microscopy

    Science.gov (United States)

    Estable, Rosita F. De; Estable-Puig, J. F.; Miquel, J.

    1964-01-01

    'l'he relative value of different methods for combined light and electron microscopical studies of glycogen in the nervous tissue was investigated. Picroalcoholic fixatives preserve glycogen in a considerable amount but give an inadequate morphological image of glycogen distribution and are unsuitable for ultrastructural studies. Fixation by perfusion, with Dalton's chromeosmic fluid seems adequate for ultrastructural cytochemistry of glycogen. Furthermore it permits routine paraffin embedding of brain slices adjacent to those used for electron microscopy. Dimedone blocking is a necessary step for a selective staining of glycogen with PAS after osmic fixation. Enzymatic removal of glycogen in osmic fixed nervous tissue can be done In paraffin-embedded tissue. It can also be performed in glycolmethacrylate-embedded tissue without removal of the embedding medium. Paraphenylenediamine stains glycogen following periodic acid oxidation.

  3. Effects of aging on the function of the urinary system: longitudinal changes with age in selected urine parameters in a hospitalized population of older adults

    Directory of Open Access Journals (Sweden)

    Chmielewski Piotr

    2016-09-01

    Full Text Available Although normal aging does not have a pernicious effect on the homeostasis of fluids, renal reserve in elderly people can be depleted. The purpose of the present study was to assess the relationship between longitudinal changes with age in basic urine parameters (specific gravity and pH in older men and women, depending on their body height and relative body weight. Longitudinal data on these two quantitative traits of the urine were available for 142 physically healthy individuals, including 68 men and 74 women. All subjects were 45 years of age at the beginning and 70 at the end of the period under investigation. All measurements were taken in accordance with internationally accepted requirements. Specific gravity was assessed using a hydrometer, and pH was measured using a pH meter. ANOVA, t-test, and regression analysis were performed. No significant sex differences in specific gravity or urine pH were observed. In both sexes, urine specific gravity decreased with age according to exponential model of regression. In men, there was a gradual increase in the pH of the urine until age 65, and the best fitting regression model was polynomial. In women, on the other hand, there was an exiguous decrease in urine pH throughout the period under study, and the best fitting regression model proved to be exponential. As the process of renal aging commences relatively early in ontogeny and manifests itself in many structural and functional changes, urinalysis and other more sophisticated methods of diagnosis of renal diseases are essential for proper assessment of health status of adults and older individuals. The rate of age-related changes in the analyzed traits of the urine was commensurate in both sexes, thereby revealing no evidence of significant sex differences in terms of renal aging in the period between 45 and 70 years of age.

  4. Bioassay method for Uranium in urine by Delay Neutron counting; Metoda Bioassay Uranium dalam urin dengan pencacahan Netron Kasip

    Energy Technology Data Exchange (ETDEWEB)

    Suratman,; Purwanto,; Sukarman-Aminjoyo, [Yogyakarta Nuclear Research Centre, National Atomic Energy Agency, Yogyakarta (Indonesia)

    1996-04-15

    A bioassay method for uranium in urine by neutron counting has been studied. The aim of this research is to obtain a bioassay method for uranium in urine which is used for the determination of internal dose of radiation workers. The bioassay was applied to the artificially uranium contaminated urine. The weight of the contaminant was varied. The uranium in the urine was irradiated in the Kartini reactor core, through pneumatic system. The delayed neutron was counted by BF3 neutron counter. Recovery of the bioassay was between 69.8-88.8 %, standard deviation was less than 10 % and the minimum detection was 0.387 {mu}g.

  5. Electron microscopy of glial cells of the central nervous system in the crab Ucides cordatus

    Directory of Open Access Journals (Sweden)

    Allodi S.

    1999-01-01

    Full Text Available Invertebrate glial cells show a variety of morphologies depending on species and location. They have been classified according to relatively general morphological or functional criteria and also to their location. The present study was carried out to characterize the organization of glial cells and their processes in the zona fasciculata and in the protocerebral tract of the crab Ucides cordatus. We performed routine and cytochemical procedures for electron microscopy analysis. Semithin sections were observed at the light microscope. The Thiéry procedure indicated the presence of carbohydrates, particularly glycogen, in tissue and in cells. To better visualize the axonal ensheathment at the ultrastructural level, we employed a method to enhance the unsaturated fatty acids present in membranes. Our results showed that there are at least two types of glial cells in these nervous structures, a light one and a dark one. Most of the dark cell processes have been mentioned in the literature as extracellular matrix, but since they presented an enveloping membrane, glycogen and mitochondria - intact and with different degrees of disruption - they were considered to be glial cells in the present study. We assume that they correspond to the perineurial cells on the basis of their location. The light cells must correspond to the periaxonal cells. Some characteristics of the axons such as their organization, ensheathment and subcellular structures are also described.

  6. Optical detection of ultrasound using an apertureless near-field scanning optical microscopy system

    Science.gov (United States)

    Ahn, Phillip; Zhang, Zhen; Sun, Cheng; Balogun, Oluwaseyi

    2013-01-01

    Laser ultrasonics techniques are power approaches for non-contact generation and detection of high frequency ultrasound on a local scale. In these techniques, optical diffraction limits the spatial information that can be accessed from a measurement. In order to improve the lateral spatial resolution, we incorporate an apertureless near-field scanning optical microscope (aNSOM) into laser ultrasonics setup for local detection of laser generated ultrasound. The aNSOM technique relies on the measurement of a weak backscattered near-field light intensity resulting from the oblique illumination of a nanoscale probe-tip positioned close to a sample surface. We enhance the optical near-field intensity by coupling light to surface plasmon polaritons (SPPs) on the shaft of an atomic force microscopy (AFM) cantilever. The SPPs propagate down the AFM shaft, localize at the tip apex, and are backscattered to the far-field when the separation distance between the probe tip and the sample surface is comparable to the probe-tip radius. The backscattered near-field intensity is dynamically modulated when an ultrasonic wave arrives at the sample surface leading to a transient change in the tip-sample separation distance. We present experimental results detailing measurement of broadband and narrowband laser generated ultrasound in solids with frequencies reaching up to 180 MHz range.

  7. Electron microscopy of the amphibian model systems Xenopus laevis and Ambystoma mexicanum.

    Science.gov (United States)

    Kurth, Thomas; Berger, Jürgen; Wilsch-Bräuninger, Michaela; Kretschmar, Susanne; Cerny, Robert; Schwarz, Heinz; Löfberg, Jan; Piendl, Thomas; Epperlein, Hans H

    2010-01-01

    In this chapter we provide a set of different protocols for the ultrastructural analysis of amphibian (Xenopus, axolotl) tissues, mostly of embryonic origin. For Xenopus these methods include: (1) embedding gastrulae and tailbud embryos into Spurr's resin for TEM, (2) post-embedding labeling of methacrylate (K4M) and cryosections through adult and embryonic epithelia for correlative LM and TEM, and (3) pre-embedding labeling of embryonic tissues with silver-enhanced nanogold. For the axolotl (Ambystoma mexicanum) we present the following methods: (1) SEM of migrating neural crest (NC) cells; (2) SEM and TEM of extracellular matrix (ECM) material; (3) Cryo-SEM of extracellular matrix (ECM) material after cryoimmobilization; and (4) TEM analysis of hyaluronan using high-pressure freezing and HABP labeling. These methods provide exemplary approaches for a variety of questions in the field of amphibian development and regeneration, and focus on cell biological issues that can only be answered with fine structural imaging methods, such as electron microscopy. Copyright © 2010 Elsevier Inc. All rights reserved.

  8. A model system using confocal fluorescence microscopy for examining real-time intracellular sodium ion regulation.

    Science.gov (United States)

    Lee, Jacqueline A; Collings, David A; Glover, Chris N

    2016-08-15

    The gills of euryhaline fish are the ultimate ionoregulatory tissue, achieving ion homeostasis despite rapid and significant changes in external salinity. Cellular handling of sodium is not only critical for salt and water balance but is also directly linked to other essential functions such as acid-base homeostasis and nitrogen excretion. However, although measurement of intracellular sodium ([Na(+)]i) is important for an understanding of gill transport function, it is challenging and subject to methodological artifacts. Using gill filaments from a model euryhaline fish, inanga (Galaxias maculatus), the suitability of the fluorescent dye CoroNa Green as a probe for measuring [Na(+)]i in intact ionocytes was confirmed via confocal microscopy. Cell viability was verified, optimal dye loading parameters were determined, and the dye-ion dissociation constant was measured. Application of the technique to freshwater- and 100% seawater-acclimated inanga showed salinity-dependent changes in branchial [Na(+)]i, whereas no significant differences in branchial [Na(+)]i were determined in 50% seawater-acclimated fish. This technique facilitates the examination of real-time changes in gill [Na(+)]i in response to environmental factors and may offer significant insight into key homeostatic functions associated with the fish gill and the principles of sodium ion transport in other tissues and organisms. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Perspective: Electronic systems of knowledge in the world of virtual microscopy.

    Science.gov (United States)

    Maybury, Terrence; Farah, Camile S

    2009-09-01

    Across a broad range of medical disciplines, learning how to use an optical or light microscope has been a mandatory inclusion in the undergraduate curriculum. The development of virtual microscopy (VM) technology during the past 10 years has called into question the use of the optical microscope in educational contexts. VM allows slide specimens to be digitized, which, in turn, allows the computer to mimic the workings of the light microscope. This move from analog technology (the light microscope) to digital technology (the computer as microscope) is part of the many significant changes going on in education, a singular manifestation of the broader move from print-literate traditions of knowledge (requiring literacy) to an electronics-literate, or "electrate," mode (requiring "electracy"). VM is here used as an exemplar of this broad transition from literacy to electracy, some components of which include data deluge, a multimodal structure, and modularity. Understandably, this transition is important to clarify educationally, especially in a global context mediated via digital means. A related aspect of these educational changes is the move from teacher-directed learning to student-centered learning, or "user-led education," which points to a redefinition of "pedagogy" as "andragogy." The dissemination of the specific value of VM, then, is critical to both learners and teachers and to a more coherent understanding of electracy. A practical consequence of this clarity might be a better application of this knowledge in the evolving fields of computer simulation and telemedicine, areas in which today's medical students will need future expertise.

  10. Development of a laser-based heating system for in situ synchrotron-based X-ray tomographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fife, Julie L., E-mail: julie.fife@psi.ch [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Rappaz, Michel [Computational Materials Laboratory, Ecole Polytechnique Federale de Lausanne, Lausanne (Switzerland); Pistone, Mattia [Institute for Geochemistry and Petrology, Swiss Federal Institute of Technology of Zurich, Zurich (Switzerland); Celcer, Tine [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); The Centre of Excellence for Biosensors, Instrumentation and Process Control, Solkan (Slovenia); Mikuljan, Gordan [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Stampanoni, Marco [Laboratory for Synchrotron Radiation, Swiss Light Source, Paul Scherrer Institut, Villigen (Switzerland); Institute for Biomedical Engineering, Swiss Federal Institute of Technology and University of Zurich, Zurich (Switzerland)

    2012-05-01

    A laser-based heating system has been developed at the TOMCAT beamline of the Swiss Light Source for in situ observations of moderate-to-high-temperature applications of materials. Understanding the formation of materials at elevated temperatures is critical for determining their final properties. Synchrotron-based X-ray tomographic microscopy is an ideal technique for studying such processes because high spatial and temporal resolutions are easily achieved and the technique is non-destructive, meaning additional analyses can take place after data collection. To exploit the state-of-the-art capabilities at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the Swiss Light Source, a general-use moderate-to-high-temperature furnace has been developed. Powered by two diode lasers, it provides controlled localized heating, from 673 to 1973 K, to examine many materials systems and their dynamics in real time. The system can also be operated in various thermal modalities. For example, near-isothermal conditions at a given sample location can be achieved with a prescribed time-dependent temperature. This mode is typically used to study isothermal phase transformations; for example, the formation of equiaxed grains in metallic systems or to nucleate and grow bubble foams in silicate melts under conditions that simulate volcanic processes. In another mode, the power of the laser can be fixed and the specimen moved at a constant speed in a user-defined thermal gradient. This is similar to Bridgman solidification, where the thermal gradient and cooling rate control the microstructure formation. This paper details the experimental set-up and provides multiple proofs-of-concept that illustrate the versatility of using this laser-based heating system to explore, in situ, many elevated-temperature phenomena in a variety of materials.

  11. Monolithic Chip System with a Microfluidic Channel for In Situ Electron Microscopy of Liquids

    DEFF Research Database (Denmark)

    Jensen, Eric; Burrows, Andrew; Mølhave, Kristian

    2014-01-01

    sandwiched microchips with thin membranes. We report on a new microfabricated chip system based on a monolithic design that enables membrane geometry on the scale of a few micrometers. The design is intended to reduce membrane deflection when the system is under pressure, a micro fluidic channel for improved...

  12. A self-contained, programmable microfluidic cell culture system with real-time microscopy access

    DEFF Research Database (Denmark)

    Skafte-Pedersen, Peder; Hemmingsen, Mette; Sabourin, David

    2011-01-01

    Utilizing microfluidics is a promising way for increasing the throughput and automation of cell biology research. We present a complete self-contained system for automated cell culture and experiments with real-time optical read-out. The system offers a high degree of user-friendliness, stability...... enables the system to perform parallel, programmable and multiconditional assays on a single chip. A modular approach provides system versatility and allows many different chips to be used dependent upon application. We validate the system's performance by demonstrating on-chip passive switching...... and mixing by peristaltically driven flows. Applicability for biological assays is demonstrated by on-chip cell culture including on-chip transfection and temporally programmable gene expression....

  13. Note: Design of FPGA based system identification module with application to atomic force microscopy

    Science.gov (United States)

    Ghosal, Sayan; Pradhan, Sourav; Salapaka, Murti

    2018-05-01

    The science of system identification is widely utilized in modeling input-output relationships of diverse systems. In this article, we report field programmable gate array (FPGA) based implementation of a real-time system identification algorithm which employs forgetting factors and bias compensation techniques. The FPGA module is employed to estimate the mechanical properties of surfaces of materials at the nano-scale with an atomic force microscope (AFM). The FPGA module is user friendly which can be interfaced with commercially available AFMs. Extensive simulation and experimental results validate the design.

  14. RELIABILITY OF CONFOCAL MICROSCOPY SPECTRAL IMAGING SYSTEMS: USE OF MULTISPECTRAL BEADS

    Science.gov (United States)

    Background: There is a need for a standardized, impartial calibration, and validation protocol on confocal spectral imaging (CSI) microscope systems. To achieve this goal, it is necessary to have testing tools to provide a reproducible way to evaluate instrument performance. ...

  15. Urine cup for collection of urine from cows.

    Science.gov (United States)

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  16. Incubator embedded cell culture imaging system (EmSight) based on Fourier ptychographic microscopy.

    Science.gov (United States)

    Kim, Jinho; Henley, Beverley M; Kim, Charlene H; Lester, Henry A; Yang, Changhuei

    2016-08-01

    Multi-day tracking of cells in culture systems can provide valuable information in bioscience experiments. We report the development of a cell culture imaging system, named EmSight, which incorporates multiple compact Fourier ptychographic microscopes with a standard multiwell imaging plate. The system is housed in an incubator and presently incorporates six microscopes. By using the same low magnification objective lenses as the objective and the tube lens, the EmSight is configured as a 1:1 imaging system that, providing large field-of-view (FOV) imaging onto a low-cost CMOS imaging sensor. The EmSight improves the image resolution by capturing a series of images of the sample at varying illumination angles; the instrument reconstructs a higher-resolution image by using the iterative Fourier ptychographic algorithm. In addition to providing high-resolution brightfield and phase imaging, the EmSight is also capable of fluorescence imaging at the native resolution of the objectives. We characterized the system using a phase Siemens star target, and show four-fold improved coherent resolution (synthetic NA of 0.42) and a depth of field of 0.2 mm. To conduct live, long-term dopaminergic neuron imaging, we cultured ventral midbrain from mice driving eGFP from the tyrosine hydroxylase promoter. The EmSight system tracks movements of dopaminergic neurons over a 21 day period.

  17. A flexible LabVIEWTM-based data acquisition and analysis system for scanning microscopy

    International Nuclear Information System (INIS)

    Morse, Daniel H.; Antolak, Arlyn J.; Bench, Graham S.; Roberts, Mark L.

    1999-01-01

    A new data analysis system has been developed with computer-controlled beam and sample positioning, video sample imaging, multiple large solid angle detectors for X-rays and gamma-rays, and surface barrier detectors for charged particles. The system uses the LabVIEW TM programming language allowing it to be easily ported between different computer operating systems. In the present configuration, digital signal processors are directly interfaced to a SCSI CAMAC controller. However, the modular software design permits the substitution of other hardware with LabVIEW-supported drivers. On-line displays of histogram and two-dimensional elemental map images provide a user-friendly data acquisition interface. Subregions of the two-dimensional maps may be selected interactively for detailed analysis or for subsequent scanning. Off-line data processing of archived data currently yields elemental maps, analyzed spectra and reconstructions of tomographic data

  18. A flexible Labviewtrademark-based data acquisition and analysis system for scanning microscopy

    International Nuclear Information System (INIS)

    Morse, Daniel H.; Antolak, Arlyn J.; Bench, Graham S.; Roberts, Mark L.

    1998-01-01

    A new data analysis system has been developed with computer-controlled beam and sample positioning, video sample imaging, multiple large solid angle detectors for x-rays and gamma-rays, and surface barrier detectors for charged particles. The system uses the LabVIEWtrademark programming language allowing it to be easily ported between different computer operating systems. In the present configuration, digital signal processors are directly interfaced to a SCSI CAMAC controller. However, the modular software design permits the substitution of other hardware with LabVIEW-supported drivers. On-line displays of histogram and two-dimensional elemental map images provide a user-friendly data acquisition interface. Subregions of the two-dimensional maps may be selected interactively for detailed analysis or for subsequent scanning. Off-line data processing of archived data currently yields elemental maps, analyzed spectra and reconstructions of tomographic data

  19. Cortisol in urine and saliva

    DEFF Research Database (Denmark)

    Hurwitz Eller, N; Netterstrøm, B; Hansen, Åse Marie

    2001-01-01

    The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis.......The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis....

  20. Selenium speciation in pretreated human urine by ion-exchange chromatography and ICP-MS detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jons, O.; Bendahl, L.

    2001-01-01

    Urine samples were extracted by benzo-15-crown-5-ether to remove sodium and potassium. More than 90% of the sodium and potassium content of the urine was removed with this extraction. In a cation-exchange system based on oxalic acid at pH 3, chromatography of an untreated urine pool resulted...

  1. Molecular neutron activation analysis of selenium metabolites in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Hansen, G.T.; Ebrahim, A.; Rack, E.P.

    1988-01-01

    Because of the biological importance of selenium in living biological systems, various analytical procedures have been developed for analysis of microquantities of elemental selenium, in urine, serum, and tissue. For urine selenium, these include atomic absorption spectrometry, solution absorption spectrometry, solution fluorescence spectrometry, volumetry, and neutron activation analysis. Of equal or greater importance is the determination of selenium metabolites present in urine for the purpose of describing the biological pathways for the metabolism of selenium in living organisms. While it is known from previous studies that trimethylselenonium ion (TMSe) is a major metabolite in urine, probably the result of reduction and methylation reaction, there are no definitive results in the literature indicating the nature or quantity of other selenium metabolic products in urine. Early techniques to measure TMSe levels in urine involved the use of the radiotracer 75 Se. Because of the long biological half-life of selenium and issues of radiation exposure, its use in humans has been limited. In this paper, the authors report the experimental procedure for the determination of total selenoamino acid concentration in urine and present total selenium values, and, where applicable, TMSe, SeO 2- 3 , and total selenoamino acid concentrations in the urine of normal and diseased subjects

  2. Imaging systems and algorithms to analyze biological samples in real-time using mobile phone microscopy.

    Science.gov (United States)

    Shanmugam, Akshaya; Usmani, Mohammad; Mayberry, Addison; Perkins, David L; Holcomb, Daniel E

    2018-01-01

    Miniaturized imaging devices have pushed the boundaries of point-of-care imaging, but existing mobile-phone-based imaging systems do not exploit the full potential of smart phones. This work demonstrates the use of simple imaging configurations to deliver superior image quality and the ability to handle a wide range of biological samples. Results presented in this work are from analysis of fluorescent beads under fluorescence imaging, as well as helminth eggs and freshwater mussel larvae under white light imaging. To demonstrate versatility of the systems, real time analysis and post-processing results of the sample count and sample size are presented in both still images and videos of flowing samples.

  3. Ag/ZnO hybrid systems studied with scanning tunnelling microscopy-based luminescence spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Pascua, Leandro; Freund, Hans-Joachim [Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, D-14195 Berlin (Germany); Stavale, Fernando [Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, D-14195 Berlin (Germany); Centro Brasileiro de Pesquisas Físicas - CBPF/MCTI, Rua Xavier Sigaud 150, 22290-180 Rio de Janeiro (Brazil); Nilius, Niklas, E-mail: niklas.nilius@uni-oldenburg.de [Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, D-14195 Berlin (Germany); Institut für Physik, Carl von Ossietzky Universität Oldenburg, D-26111 Oldenburg (Germany)

    2016-03-07

    Coupled metal/oxide systems are prepared by depositing and embedding Ag nanoparticles into crystalline ZnO films grown on Au(111) supports. The morphology and optical properties of the compounds are investigated by topographic imaging and luminescence spectroscopy performed in a scanning tunnelling microscope (STM). The luminescence of bare ZnO is governed by the band-recombination and a Zn-vacancy related peak. After Ag deposition, two additional maxima are detected that are assigned to the in-plane and out-of-plane plasmon in Ag nanoparticles and have energies below and slightly above the oxide band-gap, respectively. Upon coating the particles with additional ZnO, the out-of-plane plasmon redshifts and loses intensity, indicating strong coupling to the oxide electronic system, while the in-plane mode broadens but remains detectable. The original situation can be restored by gently heating the sample, which drives the silver back to the surface. However, the optical response of pristine ZnO is not recovered even after silver evaporation at high temperature. Small discrepancies are explained with changes in the ZnO defect landscape, e.g., due to silver incorporation. Our experiments demonstrate how energy-transfer processes can be investigated in well-defined metal/oxide systems by means of STM-based spectroscopic techniques.

  4. Ag/ZnO hybrid systems studied with scanning tunnelling microscopy-based luminescence spectroscopy

    International Nuclear Information System (INIS)

    Pascua, Leandro; Freund, Hans-Joachim; Stavale, Fernando; Nilius, Niklas

    2016-01-01

    Coupled metal/oxide systems are prepared by depositing and embedding Ag nanoparticles into crystalline ZnO films grown on Au(111) supports. The morphology and optical properties of the compounds are investigated by topographic imaging and luminescence spectroscopy performed in a scanning tunnelling microscope (STM). The luminescence of bare ZnO is governed by the band-recombination and a Zn-vacancy related peak. After Ag deposition, two additional maxima are detected that are assigned to the in-plane and out-of-plane plasmon in Ag nanoparticles and have energies below and slightly above the oxide band-gap, respectively. Upon coating the particles with additional ZnO, the out-of-plane plasmon redshifts and loses intensity, indicating strong coupling to the oxide electronic system, while the in-plane mode broadens but remains detectable. The original situation can be restored by gently heating the sample, which drives the silver back to the surface. However, the optical response of pristine ZnO is not recovered even after silver evaporation at high temperature. Small discrepancies are explained with changes in the ZnO defect landscape, e.g., due to silver incorporation. Our experiments demonstrate how energy-transfer processes can be investigated in well-defined metal/oxide systems by means of STM-based spectroscopic techniques.

  5. Note: A silicon-on-insulator microelectromechanical systems probe scanner for on-chip atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, Anthony G.; Maroufi, Mohammad; Moheimani, S. O. Reza, E-mail: Reza.Moheimani@newcastle.edu.au [School of Electrical Engineering and Computer Science, University of Newcastle, Callaghan, NSW 2308 (Australia)

    2015-04-15

    A new microelectromechanical systems-based 2-degree-of-freedom (DoF) scanner with an integrated cantilever for on-chip atomic force microscopy (AFM) is presented. The silicon cantilever features a layer of piezoelectric material to facilitate its use for tapping mode AFM and enable simultaneous deflection sensing. Electrostatic actuators and electrothermal sensors are used to accurately position the cantilever within the x-y plane. Experimental testing shows that the cantilever is able to be scanned over a 10 μm × 10 μm window and that the cantilever achieves a peak-to-peak deflection greater than 400 nm when excited at its resonance frequency of approximately 62 kHz.

  6. Determination of partition coefficients of biomolecules in a microfluidic aqueous two phase system platform using fluorescence microscopy.

    Science.gov (United States)

    Silva, D F C; Azevedo, A M; Fernandes, P; Chu, V; Conde, J P; Aires-Barros, M R

    2017-03-03

    Aqueous two phase systems (ATPS) offer great potential for selective separation of a wide range of biomolecules by exploring differences in molecular solubility in each of the two immiscible phases. However, ATPS use has been limited due to the difficulty in predicting the behavior of a given biomolecule in the partition environment together with the empirical and time-consuming techniques that are used for the determination of partition and extraction parameters. In this work, a fast and novel technique based on a microfluidic platform and using fluorescence microscopy was developed to determine the partition coefficients of biomolecules in different ATPS. This method consists of using a microfluidic device with a single microchannel and three inlets. In two of the inlets, solutions containing the ATPS forming components were loaded while the third inlet was fed with the FITC tagged biomolecule of interest prepared in milli-Q water. Using fluorescence microscopy, it was possible to follow the location of the FITC-tagged biomolecule and, by simply varying the pumping rates of the solutions, to quickly test a wide variety of ATPS compositions. The ATPS system is allowed 4min for stabilization and fluorescence micrographs are used to determine the partition coefficient.The partition coefficients obtained were shown to be consistent with results from macroscale ATPS partition. This process allows for faster screening of partition coefficients using only a few microliters of material for each ATPS composition and is amenable to automation. The partitioning behavior of several biomolecules with molecular weights (MW) ranging from 5.8 to 150kDa, and isoelectric points (pI) ranging from 4.7 to 6.4 was investigated, as well as the effect of the molecular weight of the polymer ATPS component. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. CHROMagar Orientation Medium Reduces Urine Culture Workload

    Science.gov (United States)

    Manickam, Kanchana; Karlowsky, James A.; Adam, Heather; Lagacé-Wiens, Philippe R. S.; Rendina, Assunta; Pang, Paulette; Murray, Brenda-Lee

    2013-01-01

    Microbiology laboratories continually strive to streamline and improve their urine culture algorithms because of the high volumes of urine specimens they receive and the modest numbers of those specimens that are ultimately considered clinically significant. In the current study, we quantitatively measured the impact of the introduction of CHROMagar Orientation (CO) medium into routine use in two hospital laboratories and compared it to conventional culture on blood and MacConkey agars. Based on data extracted from our Laboratory Information System from 2006 to 2011, the use of CO medium resulted in a 28% reduction in workload for additional procedures such as Gram stains, subcultures, identification panels, agglutination tests, and biochemical tests. The average number of workload units (one workload unit equals 1 min of hands-on labor) per urine specimen was significantly reduced (P < 0.0001; 95% confidence interval [CI], 0.5326 to 1.047) from 2.67 in 2006 (preimplementation of CO medium) to 1.88 in 2011 (postimplementation of CO medium). We conclude that the use of CO medium streamlined the urine culture process and increased bench throughput by reducing both workload and turnaround time in our laboratories. PMID:23363839

  8. Miniature fiber-optic multiphoton microscopy system using frequency-doubled femtosecond Er-doped fiber laser.

    Science.gov (United States)

    Huang, Lin; Mills, Arthur K; Zhao, Yuan; Jones, David J; Tang, Shuo

    2016-05-01

    We report on a miniature fiber-optic multiphoton microscopy (MPM) system based on a frequency-doubled femtosecond Er-doped fiber laser. The femtosecond pulses from the laser source are delivered to the miniature fiber-optic probe at 1.58 µm wavelength, where a standard single mode fiber is used for delivery without the need of free-space dispersion compensation components. The beam is frequency-doubled inside the probe by a periodically poled MgO:LiNbO3 crystal. Frequency-doubled pulses at 786 nm with a maximum power of 80 mW and a pulsewidth of 150 fs are obtained and applied to excite intrinsic signals from tissues. A MEMS scanner, a miniature objective, and a multimode collection fiber are further used to make the probe compact. The miniature fiber-optic MPM system is highly portable and robust. Ex vivo multiphoton imaging of mammalian skins demonstrates the capability of the system in imaging biological tissues. The results show that the miniature fiber-optic MPM system using frequency-doubled femtosecond fiber laser can potentially bring the MPM imaging for clinical applications.

  9. Efficient Execution of Microscopy Image Analysis on CPU, GPU, and MIC Equipped Cluster Systems.

    Science.gov (United States)

    Andrade, G; Ferreira, R; Teodoro, George; Rocha, Leonardo; Saltz, Joel H; Kurc, Tahsin

    2014-10-01

    High performance computing is experiencing a major paradigm shift with the introduction of accelerators, such as graphics processing units (GPUs) and Intel Xeon Phi (MIC). These processors have made available a tremendous computing power at low cost, and are transforming machines into hybrid systems equipped with CPUs and accelerators. Although these systems can deliver a very high peak performance, making full use of its resources in real-world applications is a complex problem. Most current applications deployed to these machines are still being executed in a single processor, leaving other devices underutilized. In this paper we explore a scenario in which applications are composed of hierarchical data flow tasks which are allocated to nodes of a distributed memory machine in coarse-grain, but each of them may be composed of several finer-grain tasks which can be allocated to different devices within the node. We propose and implement novel performance aware scheduling techniques that can be used to allocate tasks to devices. We evaluate our techniques using a pathology image analysis application used to investigate brain cancer morphology, and our experimental evaluation shows that the proposed scheduling strategies significantly outperforms other efficient scheduling techniques, such as Heterogeneous Earliest Finish Time - HEFT, in cooperative executions using CPUs, GPUs, and MICs. We also experimentally show that our strategies are less sensitive to inaccuracy in the scheduling input data and that the performance gains are maintained as the application scales.

  10. Parallel and Efficient Sensitivity Analysis of Microscopy Image Segmentation Workflows in Hybrid Systems.

    Science.gov (United States)

    Barreiros, Willian; Teodoro, George; Kurc, Tahsin; Kong, Jun; Melo, Alba C M A; Saltz, Joel

    2017-09-01

    We investigate efficient sensitivity analysis (SA) of algorithms that segment and classify image features in a large dataset of high-resolution images. Algorithm SA is the process of evaluating variations of methods and parameter values to quantify differences in the output. A SA can be very compute demanding because it requires re-processing the input dataset several times with different parameters to assess variations in output. In this work, we introduce strategies to efficiently speed up SA via runtime optimizations targeting distributed hybrid systems and reuse of computations from runs with different parameters. We evaluate our approach using a cancer image analysis workflow on a hybrid cluster with 256 nodes, each with an Intel Phi and a dual socket CPU. The SA attained a parallel efficiency of over 90% on 256 nodes. The cooperative execution using the CPUs and the Phi available in each node with smart task assignment strategies resulted in an additional speedup of about 2×. Finally, multi-level computation reuse lead to an additional speedup of up to 2.46× on the parallel version. The level of performance attained with the proposed optimizations will allow the use of SA in large-scale studies.

  11. Microscopy system of atomic force based on a digital optical reading unit and a buzzer-scanner

    International Nuclear Information System (INIS)

    Dabirian, R.; Loza M, D.; Wang, W. M.; Hwu, E. T.

    2015-01-01

    An astigmatic detection system (Ads) based on a compact disk/digital-versatile-disk (Cd-DVD) astigmatic optical pickup unit is presented. It can achieve a resolution better than 0.3 nm in detection of the vertical displacement and is able to detect the two-dimensional angular tilt of the object surface. Furthermore, a novel scanner design actuated by piezoelectric disk buzzers is presented. The scanner is composed of a quad-rod actuation structure and several piezoelectric disks. It can be driven directly with low-voltage and low-current sources, such as analogue outputs of a data acquisition card and enables a sufficient scanning range of up to μm. In addition, an economic, high-performance streamlined atomic force microscopy (AFM) was constructed, using the buzzer-scanner to move the sample relative to the probe, and using a Cd/DVD optical pickup unit to detect the mechanical resonance of a micro fabricated cantilever. The performance of the AFM is evaluated. The high sensitivity and high bandwidth of the detection system makes the equipment suitable for characterizing nano scale elements. An AFM using our detection system for detecting the deflection of micro fabricated cantilevers can resolve individual atomic steps on graphite surfaces. (Author)

  12. Capillary loss on nailfold capillary microscopy is associated with mortality in systemic sclerosis.

    Science.gov (United States)

    Pavan, Thais Rohde; Bredemeier, Markus; Hax, Vanessa; Capobianco, Karina Gatz; da Silva Mendonça Chakr, Rafael; Xavier, Ricardo Machado

    2018-02-01

    The objective of this study is to test the association of the severity of nailfold capillaroscopy (NFC) abnormalities with mortality in systemic sclerosis (SSc). One hundred and seventy SSc patients underwent an extensive evaluation (including high-resolution computed tomography, pulmonary function tests, and Doppler echocardiography) at baseline following a standard protocol. Capillary loss on NFC was evaluated using the avascular score (AS, ranging from 0 to 3), and the mean number of ectasias, megacapillaries, and hemorrhages per finger was also recorded. After a mean period of 10.1 ± 4.9 years, the life status of the patients was ascertained. Univariate and multivariate Cox proportional hazards models were used for statistical analysis. Overall, 73 patients died. By univariate Cox analysis, the AS was significantly associated with mortality (hazard ratio [HR] = 1.64, 95% CI 1.22 to 2.19, p = 0.001). In our study, this association was stronger than that of race, gender, anticentromere antibodies, anti-topoisomerase I antibodies, and form of disease and had similar strength to that of skin score in univariate analyses. However, after controlling for a combination of variables (age, skin score, gender, race, signs of peripheral ischemia, and extent of interstitial lung disease, all independently associated with mortality), the association of AS with mortality was blunted (HR = 1.15, 95% CI 0.80 to 1.65, p = 0.445). Other NFC variables were not related to mortality. AS was associated with higher risk of death and, despite not having an independent association with mortality after controlling for a set of demographic and clinical variables, may be a useful tool in prognostic evaluation of SSc.

  13. Virtual microscopy system at Chinese medical university: an assisted teaching platform for promoting active learning and problem-solving skills.

    Science.gov (United States)

    Tian, Yanping; Xiao, Wengang; Li, Chengren; Liu, Yunlai; Qin, Maolin; Wu, Yi; Xiao, Lan; Li, Hongli

    2014-04-09

    Chinese medical universities typically have a high number of students, a shortage of teachers and limited equipment, and as such histology courses have been taught using traditional lecture-based formats, with textbooks and conventional microscopy. This method, however, has reduced creativity and problem-solving skills training in the curriculum. The virtual microscope (VM) system has been shown to be an effective and efficient educational strategy. The present study aims to describe a VM system for undergraduates and to evaluate the effects of promoting active learning and problem-solving skills. Two hundred and twenty-nine second-year undergraduate students in the Third Military Medical University were divided into two groups. The VM group contained 115 students and was taught using the VM system. The light microscope (LM) group consisted of 114 students and was taught using the LM system. Post-teaching performances were assessed by multiple-choice questions, short essay questions, case analysis questions and the identification of structure of tissue. Students' teaching preferences and satisfaction were assessed using questionnaires. Test scores in the VM group showed a significant improvement compared with those in the LM group (p 0.05); however, there were notable differences in the mean score rate of case analysis questions and identification of structure of tissue (p effects of the VM system in terms of additional learning resources, critical thinking, ease of communication and confidence. The VM system is an effective tool at Chinese medical university to promote undergraduates' active learning and problem-solving skills as an assisted teaching platform.

  14. An integrated optical coherence microscopy imaging and optical stimulation system for optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    Electrical stimulation is the clinical standard for cardiac pacing. Although highly effective in controlling cardiac rhythm, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its applications. Optogenetic pacing of the heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids the shortcomings in electrical stimulation. Drosophila melanogaster, which is a powerful model organism with orthologs of nearly 75% of human disease genes, has not been studied for optogenetic pacing in the heart. Here, we developed a non-invasive integrated optical pacing and optical coherence microscopy (OCM) imaging system to control the heart rhythm of Drosophila at different developmental stages using light. The OCM system is capable of providing high imaging speed (130 frames/s) and ultrahigh imaging resolutions (1.5 μm and 3.9 μm for axial and transverse resolutions, respectively). A light-sensitive pacemaker was developed in Drosophila by specifically expressing the light-gated cation channel, channelrhodopsin-2 (ChR2) in transgenic Drosophila heart. We achieved non-invasive and specific optical control of the Drosophila heart rhythm throughout the fly's life cycle (larva, pupa, and adult) by stimulating the heart with 475 nm pulsed laser light. Heart response to stimulation pulses was monitored non-invasively with OCM. This integrated non-invasive optogenetic control and in vivo imaging technique provides a novel platform for performing research studies in developmental cardiology.

  15. Efficacy of Two Irrigants Used with Self-Adjusting File System on Smear Layer: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Genç Şen, Özgür; Kaya, Sadullah; Er, Özgür; Alaçam, Tayfun

    2014-01-01

    Mechanical instrumentation of root canals produces a smear layer that adversely affects the root canal seal. The aim of this study was to evaluate efficacy of MTAD and citric acid solutions used with self-adjusting file (SAF) system on smear layer. Twenty-three single-rooted human teeth were used for the study. Canals were instrumented manually up to a number 20 K file size. SAF was used to prepare the root canals. The following groups were studied: Group 1: MTAD + 5.25% NaOCl, Group 2: 20% citric acid + 5.25% NaOCl, and Group 3: Control (5.25% NaOCl). All roots were split longitudinally and subjected to scanning electron microscopy. The presence of smear layer in the coronal, middle, and apical thirds was evaluated using a five-score evaluation system. Kruskal-Wallis and Mann-Whitney U tests were used for statistical analysis. In the coronal third, Group 2 exhibited the best results and was statistically different froms the other groups (P 0.05). The solutions used in Group 1 and 2 could effectively remove smear layer in most of the specimens. However, citric acid was more effective than MTAD in the three thirds of the canal.

  16. Introducing measure-by-wire, the systematic use of systems and control theory in transmission electron microscopy

    International Nuclear Information System (INIS)

    Tejada, Arturo; Dekker, Arnold J. den; Van den Broek, Wouter

    2011-01-01

    Transmission electron microscopes (TEMs) are the tools of choice for academic and industrial research at the nano-scale. Due to their increasing use for routine, repetitive measurement tasks (e.g., quality control in production lines) there is a clear need for a new generation of high-throughput microscopes designed to autonomously extract information from specimens (e.g., particle size distribution, chemical composition, structural information, etc.). To aid in their development, a new engineering perspective on TEM design, based on principles from systems and control theory, is proposed here: measure-by-wire (not to be confused with remote microscopy). Under this perspective, the TEM operator yields the direct control of the microscope's internal processes to a hierarchy of feedback controllers and high-level supervisors. These make use of dynamical models of the main TEM components together with currently available measurement techniques to automate processes such as defocus correction or specimen displacement. Measure-by-wire is discussed in depth, and its methodology is illustrated through a detailed example: the design of a defocus regulator, a type of feedback controller that is akin to existing autofocus procedures. -- Highlights: ► High-throughput TEM operation is increasingly needed for research and industry. ► Autonomous high-throughput TEMs enabled by systems and control theory. ► Measure-by-wire is a new holistic automation oriented engineering view of TEM. ► A detailed example shows how to apply MBW to the automatic control of defocus.

  17. Catecholamines, Plasma and Urine Test

    Science.gov (United States)

    ... and Iron-binding Capacity (TIBC, UIBC) Trichomonas Testing Triglycerides Troponin Tryptase Tumor Markers Uric Acid Urinalysis Urine ... blood pressure, and epinephrine increases heart rate and metabolism . After completing their actions, catecholamines are metabolized to ...

  18. The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis.

    Science.gov (United States)

    Ellidag, Hamit Yasar; Curek, Gulten; Eren, Esin; Aydin, Ozgur; Yilmaz, Necat

    2015-01-01

    Immunofixation electrophoresis (IFE) maintains its importance in diagnosing monoclonal gammopathies. In particular, urine IFE detects free light chains (FLC) in urine samples even at low concentrations and offers higher sensitivity compared to serum electrophoresis and serum IFE. The aim of the present study was to determine the place and significance of quantitative urinary protein measurement before IFE in interpreting the results of subsequent IFE and to determine the most appropriate protein concentrations for the appearance of bands. The records of a total of 600 patients, who underwent screening for Bence Jones proteinuria using IFE on 24-hour urine, were retrospectively reviewed. Urine IFE was performed using Helena SAS-I and SAS-I devices. The total protein concentration in the urine was quantitatively determined by the Pyrogallol red method, and the urine albumin level was determined using the immunoturbidimetric method. These analyses were measured on an Olympus/Beckmann AU5800. The evaluation of IFE results revealed that 311 patients had normal results, 108 patients had monoclonal bands, five patients had biclonal bands, 28 had polyclonal bands, and 148 patients had various degrees of proteinuria. ROC curves were created in order to determine the most appropriate urinary protein and albumin levels to observe bands in IFE. Accordingly, urine baseline protein level (mg/dL) showed the highest AUC value (cutoff value: 19.4 mg/dL, sensitivity: 92%, specificity: 98.2%, AUC: 0.972). The present study showed that quantitative protein measurement before IFE eliminated the disadvantages associated with the IFE method and its interpretation.

  19. Increasing the spatial scale of process-based agricultural systems models by representing heterogeneity: The case of urine patches in grazed pastures

    DEFF Research Database (Denmark)

    Snow, Val O.; Cichota, R; McAuliffe, John

    2017-01-01

    -paddock simulation. It explicitly preserves the soil carbon and nitrogen heterogeneity but does not require independent simulation of soil water and plant processes and is temporal in that the patches of heterogeneity can appear and disappear during the simulation. The approach was tested through comparison...... to simulations that more-closely represented field conditions and which contained independent urine patches. The testing was successful, reducing substantial error in the simulation of pasture grazed and leaching for modest increases in simulation execution time but we recommend additional testing under very low...

  20. Interaction of cement model systems with superplasticizers investigated by atomic force microscopy, zeta potential, and adsorption measurements.

    Science.gov (United States)

    Ferrari, Lucia; Kaufmann, Josef; Winnefeld, Frank; Plank, Johann

    2010-07-01

    Polyelectrolyte-based dispersants are commonly used in a wide range of industrial applications to provide specific workability to colloidal suspensions. Their working mechanism is based on adsorption onto the surfaces of the suspended particles. The adsorbed polymer layer can exercise an electrostatic and/or a steric effect which is responsible for achieving dispersion. This study is focused on the dispersion forces induced by polycarboxylate ether-based superplasticizers (PCEs) commonly used in concrete. They are investigated by atomic force microscopy (AFM) applying standard silicon nitride tips exposed to solutions with different ionic compositions in a wet cell. Adsorption isotherms and zeta potential analysis were performed to characterize polymer displacement in the AFM system on nonreactive model substrates (quartz, mica, calcite, and magnesium oxide) in order to avoid the complexity of cement hydration products. The results show that PCE is strongly adsorbed by positively charged materials. This fact reveals that, being silicon nitride naturally positively charged, in most cases the superplasticizer adsorbs preferably on the silicon nitride tip than on the AFM substrate. However, the force-distance curves displayed repulsive interactions between tip and substrates even when polymer was poorly adsorbed on both. These observations allow us to conclude that the dispersion due to PCE strongly depends on the particle charge. It differs between colloids adsorbing and not adsorbing PCE, and leads to different forces acting between the particles. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Exceptionally preserved Cambrian trilobite digestive system revealed in 3D by synchrotron-radiation X-ray tomographic microscopy.

    Directory of Open Access Journals (Sweden)

    Mats E Eriksson

    Full Text Available The Cambrian 'Orsten' fauna comprises exceptionally preserved and phosphatised microscopic arthropods. The external morphology of these fossils is well known, but their internal soft-tissue anatomy has remained virtually unknown. Here, we report the first non-biomineralised tissues from a juvenile polymerid trilobite, represented by digestive structures, glands, and connective strands harboured in a hypostome from the Swedish 'Orsten' fauna. Synchrotron-radiation X-ray tomographic microscopy enabled three-dimensional internal recordings at sub-micrometre resolution. The specimen provides the first unambiguous evidence for a J-shaped anterior gut and the presence of a crop with a constricted alimentary tract in the Trilobita. Moreover, the gut is Y-shaped in cross section, probably due to a collapsed lumen of that shape, another feature which has not previously been observed in trilobites. The combination of anatomical features suggests that the trilobite hypostome is functionally analogous to the labrum of euarthropods and that it was a sophisticated element closely integrated with the digestive system. This study also briefly addresses the preservational bias of the 'Orsten' fauna, particularly the near-absence of polymerid trilobites, and the taphonomy of the soft-tissue-harbouring hypostome.

  2. In situ electron microscopy studies of electromechanical behavior in metals at the nanoscale using a novel microdevice-based system

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Wonmo, E-mail: wonmo.kang.ctr.ks@nrl.navy.mil; Beniam, Iyoel; Qidwai, Siddiq M. [Naval Research Laboratory, Washington, DC 20375 (United States)

    2016-09-15

    Electrically assisted deformation (EAD) is an emerging technique to enhance formability of metals by applying an electric current through them. Despite its increasing importance in manufacturing applications, there is still an unresolved debate on the nature of the fundamental deformation mechanisms underlying EAD, mainly between electroplasticity (non-thermal effects) and resistive heating (thermal effects). This status is due to two critical challenges: (1) a lack of experimental techniques to directly observe fundamental mechanisms of material deformation during EAD, and (2) intrinsic coupling between electric current and Joule heating giving rise to unwanted thermally activated mechanisms. To overcome these challenges, we have developed a microdevice-based electromechanical testing system (MEMTS) to characterize nanoscale metal specimens in transmission electron microscopy (TEM). Our studies reveal that MEMTS eliminates the effect of Joule heating on material deformation, a critical advantage over macroscopic experiments, owing to its unique scale. For example, a negligible change in temperature (<0.02 °C) is predicted at ∼3500 A/mm{sup 2}. Utilizing the attractive features of MEMTS, we have directly investigated potential electron-dislocation interactions in single crystal copper (SCC) specimens that are simultaneously subjected to uniaxial loading and electric current density up to 5000 A/mm{sup 2}. Our in situ TEM studies indicate that for SCC, electroplasticity does not play a key role as no differences in dislocation activities, such as depinning and movement, are observed.

  3. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    Science.gov (United States)

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  4. The effects of gliadin on urine metabolome in mice

    DEFF Research Database (Denmark)

    Roager, Henrik Munch; Zhang, Li; Frandsen, Henrik Lauritz

    Gliadin, a proline-rich protein of gluten, is thought to modulate the gut microbiota and affect the intestinal permeability and immune system. However, little is known about the long-term effects of gliadin on the host and microbial metabolism. To study this, we compared the urine metabolome of two...... groups of mice, which were on a high fat diet with and without gliadin, respectively, for 23 weeks. Using liquid chromatography mass-spectrometry (MS) followed by multivariate analyses we were able to show a clear separation of the two groups of mice based on their urine metabolome. Discriminating...... in the gliadin mice. Also, Maillard reaction products and β-oxidized tocopherols were observed in higher levels in the urine of gliadin mice, suggesting increased oxidative stress in the gliadin mice. Indisputably, gliadin affected the urine metabolome. However, the mechanisms behind the observed metabolite...

  5. Complexation-mediated electromembrane extraction of highly polar basic drugs – a fundamental study with catecholamines in urine as model system

    DEFF Research Database (Denmark)

    Fernández, Elena; Vårdal, Linda; Vidal, Lorena

    2017-01-01

    Complexation-mediated electromembrane extraction (EME) of highly polar basic drugs (log P ... as complexation reagent, and selectively formed boronate esters by reversible covalent binding with the model analytes at the sample/SLM interface. This enhanced the mass transfer of the highly polar model analytes across the SLM, and EME of basic drugs with log P in the range -1 to -2 was shown for the first...... chromatography coupled to tandem mass spectrometry and evaluated for quantification of epinephrine and dopamine. Standard addition calibration was applied to a pooled human urine sample. Calibration curves using standards between 25 and 125 μg L-1 gave a high level of linearity with a correlation coefficient...

  6. Urine Sodium in 3 Consecutive Days Urine collected from ...

    African Journals Online (AJOL)

    Epidemiological and experimental studies have shown that salt sensitivity, which is a heritable trait, is a hallmark to hypertension in blacks. Previous studies on twenty-four hour urinary sodium were either incomplete or yielded contradictory results possibly from incomplete urine collection. This study attempted complete ...

  7. TRH radioimmunoassay for unextracted human urine

    International Nuclear Information System (INIS)

    Mitsuma, Terunori; Hirooka, Yoshibumi; Nihei, Noriyuki

    1975-01-01

    The authors developed a TRH radioimmunoassay for unextracted human urine using anti-TRH antibody produced by immunization of rabbits with a TRH-bis-diazotized-bovine serum albumin conjugate. The antibody had no crossreactivity with TRH analogues, amino acids or pituitary hormones, but with L or DL-Aze3-TRH. TRH was radioiodinized by Greenwood-Hunter's method, followed by purification on Sephadex G-10. Inactivation of TRH by serum was well documented. The authors found however that this inactivation of TRH could be prevented by adjusting the pH to 3.0 or by keeping the temperature between 4 0 C and -20 0 C. All assay procedures were performed in 0.01 M phosphate buffer with 0.15 M NaCl (pH 7.5) at 4 0 C. Free and bound forms were separated with a second antibody system. In this system, sensitivity was 0.01 ng/tube, recovery was approximately 100%, intrassay reproducibility was 3.2% and interassay variation was 9.8%. TRH levels in urine measured with this system were undetectable to 9.0 ng/ml in normal subjects, undetectable in hyperthyroid patients or a tertiary hypothyroid patient and 13 to 24 ng/ml in primary hypothyroid patients. Approximately 6 percent of the intravenously administered TRH was excreted into the urine within 12 hours following administration in a normal subject. As a result this assay system is quite attractive for clinical determination as well as research application. (Evans, J.)

  8. Non-linear microscopy and its applications for the study of the structure and dynamics of biological systems

    CSIR Research Space (South Africa)

    Sparrow, RW

    2008-01-01

    Full Text Available be differentiated (Clay et al. 2006). 6 References BARAD, Y., EISENBERG, H., HOROWITZ, M. And SILBERBERG, Y. “Nonlinear scanning laser microscopy by thrid harmonic generation“ Appl Phys Lett vol.70 (8) p.922 – 924, 1997 BARILLE,R., CANIONI,L., RIVET,S...

  9. Cholesteric lyomesophases based on sodium N-lauroyl asparte: characterization of new system by nuclear magnetic resonance and polarizing microscopy

    International Nuclear Information System (INIS)

    Melo, M.V.M.C. de.

    1982-01-01

    Lyomesophases based on di-sodium N-lauroyl aspartate (SNLA), bi-carboxilated amphiphile obtained from the reaction of n-lauroyl chloride with aspartic acid in racemic or levo form are studies. The different mesophases were characterized by 2 H and 23 Na NMR and by polarizing microscopy. (M.J.C.) [pt

  10. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    Science.gov (United States)

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. CORRELATION OF SPOT URINE ALBUMIN AND 12-HOUR URINE PROTEIN WITH 24-HOUR URINE PROTEIN IN PRE-ECLAMPSIA

    Directory of Open Access Journals (Sweden)

    S. Vinayachandran

    2017-11-01

    Full Text Available BACKGROUND Pre-eclampsia is defined as the development of new-onset hypertension in the second half of pregnancy often accompanied by new-onset proteinuria with other signs and symptoms. Proteinuria is defined by the excretion of 300 mg or more of protein in a 24-hour urine collection. To avoid time consumed in collection of 24-hour urine specimens, efforts have been made to develop faster methods to determine concentration of urine protein. Preliminary studies have suggested that 12-hour urine protein collection maybe adequate for evaluation of pre-eclampsia with advantage of early diagnosis and treatment of pre-eclampsia as well as potential for early hospital discharge and increased compliance with specimen collection. The aim of the study is to evaluate and correlate spot urine albumin and 12-hour urine protein with 24-hour urine protein in pre-eclampsia. MATERIALS AND METHODS A diagnostic evaluation study- a 24-hour urine protein, 12-hour urine protein and spot urine albumin results are analysed. Correlation of 12-hour urine protein and spot urine albumin with 24-hour urine protein is analysed using SPSS software. The strength of correlation was measured by Pearson’s correlation coefficient (r. Student’s t-test and Chi-square tests were used to compare patients with and without 24-hour urine protein ≥300 mg. Probability value of 165 mg with 24-hour urine protein ≥300 mg suggest that this test has role in the evaluation of women with suspected pre-eclampsia and could be substituted for 24-hour urine protein as a simple, faster and cheaper method.

  12. Heavy-ion microscopy

    International Nuclear Information System (INIS)

    Kraft, G.; Yang, T.C.H.; Richards, T.; Tobias, C.A.

    1980-01-01

    This chapter briefly describes the techniques of optical microscopy, scanning and transmission electron microscopy, soft x-ray microscopy and compares these latter techniques with heavy-ion microscopy. The resolution obtained with these various types of microscopy are compared and the influence of the etching procedure on total resolution is discussed. Several micrographs of mammalian cells are included

  13. Confocal Microscopy

    Science.gov (United States)

    Liu, Jian; Tan, Jiubin

    2016-12-01

    The confocal microscope is appropriate for imaging cells or the measurement of industrial artefacts. However, junior researchers and instrument users sometimes misuse imaging concepts and metrological characteristics, such as position resolution in industrial metrology and scale resolution in bio-imaging. And, metrological characteristics or influence factors in 3D measurement such as height assessment error caused by 3D coupling effect are so far not yet identified. In this book, the authors outline their practices by the working experiences on standardization and system design. This book assumes little previous knowledge of optics, but rich experience in engineering of industrial measurements, in particular with profile metrology or areal surface topography will be very helpful to understand the theoretical concerns and value of the technological advances. It should be useful for graduate students or researchers as extended reading material, as well as microscope users alongside their handbook.

  14. Nutrient and energy recovery from urine

    NARCIS (Netherlands)

    Kuntke, P.

    2013-01-01

    Keywords: urine, urine treatment, nutrient recovery, microbial fuel cells, energy production from urine, membrane capacitive deionization.

    In conventional wastewater treatment plants large amounts of energy are required for the removal and recovery of nutrients (i.e. nitrogen and

  15. On-Demand Urine Analyzer

    Science.gov (United States)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  16. Determination of americium in urine

    International Nuclear Information System (INIS)

    Shvydko, N.S.; Mikhajlova, O.A.; Popov, D.K.

    1988-01-01

    A technique has been developed for the determination of americium 241 in urine by a raiochemical purification of the nuclide from uranium (upon co-precipitation of americium 241 with calcium and lanthanum), plutonium, thorum, and polonium 210 (upon co-precipitation of these radionuclides with zirconium iodate). α-Radioactivity was measured either in a thick layer of the americium 241 precipitate with a nonisotope carrier or in thin-layer preparations after electrolytic precipitation of americium 241 on a cathode

  17. Electrochemical force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kalinin, Sergei V.; Jesse, Stephen; Collins, Liam F.; Rodriguez, Brian J.

    2017-01-10

    A system and method for electrochemical force microscopy are provided. The system and method are based on a multidimensional detection scheme that is sensitive to forces experienced by a biased electrode in a solution. The multidimensional approach allows separation of fast processes, such as double layer charging, and charge relaxation, and slow processes, such as diffusion and faradaic reactions, as well as capturing the bias dependence of the response. The time-resolved and bias measurements can also allow probing both linear (small bias range) and non-linear (large bias range) electrochemical regimes and potentially the de-convolution of charge dynamics and diffusion processes from steric effects and electrochemical reactivity.

  18. Development of Personalized Urination Recognition Technology Using Smart Bands

    Directory of Open Access Journals (Sweden)

    Sung-Jong Eun

    2017-04-01

    Full Text Available Purpose This study collected and analyzed activity data sensed through smart bands worn by patients in order to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for recognizing urination activity in patients, this study aimed to explore the feasibility of urination monitoring systems. Methods This study aimed to develop an algorithm that recognizes urination based on a patient’s posture and changes in posture. Motion data was obtained from a smart band on the arm. An algorithm that recognizes the 3 stages of urination (forward movement, urination, backward movement was developed based on data collected from a 3-axis accelerometer and from tilt angle data. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the absolute value of the signals was calculated and then compared with the set threshold value to determine the occurrence of vibration signals. In feature extraction, the most essential information describing each pattern was identified after analyzing the characteristics of the data. The results of the feature extraction process were sorted using a classifier to detect urination. Results An experiment was carried out to assess the performance of the recognition technology proposed in this study. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 90.4%, proving the robustness of the proposed algorithm. Conclusions The proposed urination recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after comparative analyses with standardized feature patterns.

  19. [Estimation of mercury in the urine of cigarette smokers].

    Science.gov (United States)

    Kulikowska-Karpińska, Elżbieta; Zdanowicz, Magdalena; Gałażyn-Sidorczuk, Małgorzata

    Cigarette smoking is one of the most common habits of the modern world. According to a NATPOL PLU study, every third adult Pole is dependent on nicotine. Tobacco smoke contains about 5,000 components, of which over 1,000 are very toxic chemical substances (3,4-benzopyrene, heavy metals, free radicals, hydrogen cyanide, nitrogen oxides and N-nitrosamines). Exposure to tobacco smoke is an example of a complex, with a significant number of interactions. To assess the concentration of copper in the urine of smokers. Based on the results, an attempt was made to determine whether smoking can affect the level of copper in the body. The study involved 170 healthy volunteers, 99 smokers and 71 non-smokers (control group). The age of patients in both groups were in the range of 20-60 years. The mean age for men and women was 41 years. The average length of cigarette smoking was 18 years for women and 21 years for men, and the number of cigarettes smoked 1-40 ⁄ 24. The urine concentrations of Cu were determined by atomic absorption spectrometry (AAS) and serum creatinine kinetic method using a set of BIOLAB. Cu concentration in urine was expressed in mg / g creatinine. Smokers were found to have reduced levels of copper in the urine, depending on sex, age and brand of cigarettes. In male smokers, copper concentration in the urine was dependent on age and time of smoking, whereas among women this relationship was not observed. Cigarette smoking significantly influences the level of copper in the urine. Both female and male smokers showed reduced levels of copper in the urine, which may indicate its increased accumulation in the body. Excessive accumulation of copper is very dangerous since it may exhibit toxic effects towards many organs and systems.

  20. Mining the human urine proteome for monitoring renal transplant injury

    Energy Technology Data Exchange (ETDEWEB)

    Sigdel, Tara K.; Gao, Yuqian; He, Jintang; Wang, Anyou; Nicora, Carrie D.; Fillmore, Thomas L.; Shi, Tujin; Webb-Robertson, Bobbie-Jo; Smith, Richard D.; Qian, Wei-Jun; Salvatierra, Oscar; Camp, David G.; Sarwal, Minnie M.

    2016-06-01

    The human urinary proteome reflects systemic and inherent renal injury perturbations and can be analyzed to harness specific biomarkers for different kidney transplant injury states. 396 unique urine samples were collected contemporaneously with an allograft biopsy from 396 unique kidney transplant recipients. Centralized, blinded histology on the graft was used to classify matched urine samples into categories of acute rejection (AR), chronic allograft nephropathy (CAN), BK virus nephritis (BKVN), and stable graft (STA). Liquid chromatography–mass spectrometry (LC-MS) based proteomics using iTRAQ based discovery (n=108) and global label-free LC-MS analyses of individual samples (n=137) for quantitative proteome assessment were used in the discovery step. Selected reaction monitoring (SRM) was applied to identify and validate minimal urine protein/peptide biomarkers to accurately segregate organ injury causation and pathology on unique urine samples (n=151). A total of 958 proteins were initially quantified by iTRAQ, 87% of which were also identified among 1574 urine proteins detected in LC-MS validation. 103 urine proteins were significantly (p<0.05) perturbed in injury and enriched for humoral immunity, complement activation, and lymphocyte trafficking. A set of 131 peptides corresponding to 78 proteins were assessed by SRM for their significance in an independent sample cohort. A minimal set of 35 peptides mapping to 33 proteins, were modeled to segregate different injury groups (AUC =93% for AR, 99% for CAN, 83% for BKVN). Urinary proteome discovery and targeted validation identified urine protein fingerprints for non-invasive differentiation of kidney transplant injuries, thus opening the door for personalized immune risk assessment and therapy.

  1. Deep Learning Microscopy

    KAUST Repository

    Rivenson, Yair

    2017-05-12

    We demonstrate that a deep neural network can significantly improve optical microscopy, enhancing its spatial resolution over a large field-of-view and depth-of-field. After its training, the only input to this network is an image acquired using a regular optical microscope, without any changes to its design. We blindly tested this deep learning approach using various tissue samples that are imaged with low-resolution and wide-field systems, where the network rapidly outputs an image with remarkably better resolution, matching the performance of higher numerical aperture lenses, also significantly surpassing their limited field-of-view and depth-of-field. These results are transformative for various fields that use microscopy tools, including e.g., life sciences, where optical microscopy is considered as one of the most widely used and deployed techniques. Beyond such applications, our presented approach is broadly applicable to other imaging modalities, also spanning different parts of the electromagnetic spectrum, and can be used to design computational imagers that get better and better as they continue to image specimen and establish new transformations among different modes of imaging.

  2. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    Science.gov (United States)

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  3. The Recovery of Water and Nitrogen from Urine in BLSS

    Science.gov (United States)

    Xie, Beizhen; Liu, Hong; Deng, Shengda

    The recycle and reuse of the wastewater is one of the main factors for realizing a higher closure degree of bioregenerative life support system (BLSS), and the treatment and recovery of the crew’s urine are the most difficult and critical issues. Urine contains a lot of water and high concentrations of urea and salts. Water can be used for the irrigation of the plants in BLSS, and the nitrogen is also the necessary nutrient for plant growth. Therefore, if the nitrogen could be recycled simultaneously while desalting the urine, the substance circulation and the closure of BLSS could be improved significantly. In this study, two-step method was conducted to treat the urine and recycle the water and nitrogen. The urea was hydrolyzed firstly, and then the water vapor and ammonia gas were cooled and collected by using reduced pressure distillation in alkaline condition. High temperature acidification and urease processing methods were studied during the urea hydrolysis step. The treatment conditions of both methods were optimized and the degrees of hydrolysis were compared. This investigation may provide a reference for the establishment of the urine recycle in BLSS.

  4. The migration of drugs-of-abuse from Europe to Denmark – Analysis of pooled anonymous urine from urinals at Roskilde Festival 2016

    DEFF Research Database (Denmark)

    Hoegberg, Lotte Christine Groth; Christiansen, Cecilie; Soe, Jesper

    of NPS, traditional treatment guidelines are challenged. Thus, information of the emergence of new arrivals is of great value. Our knowledge on the actual range of drugs used and NPS available in Denmark is limited as identification is possible only when consumers become patients in the healthcare system...... or through police seizures [2]. We carried out a cross-sectional study of collected pooled anonymous urine, sampled from urinals at the biggest music festival during the year, Roskilde Festival, with the aim to detect classic recreational drugs and NPS. The aim of this study was to identify recreational...... drugs currently used and predict the emergence of NPS by comparing study data with seizure data from the previous year published by EMCDDA [1]. Methods: In total 44 urine samples were collected from three urinals at Roskilde Festival 2016. Two urinals were placed at music stages with late-night concerts...

  5. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples

  6. Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.

    Science.gov (United States)

    Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang

    2015-01-01

    The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low

  7. Urine Exosomes: An Emerging Trove of Biomarkers.

    Science.gov (United States)

    Street, J M; Koritzinsky, E H; Glispie, D M; Star, R A; Yuen, P S T

    Exosomes are released by most cells and can be isolated from all biofluids including urine. Exosomes are small vesicles formed as part of the endosomal pathway that contain cellular material surrounded by a lipid bilayer that can be traced to the plasma membrane. Exosomes are potentially a more targeted source of material for biomarker discovery than unfractionated urine, and provide diagnostic and pathophysiological information without an invasive tissue biopsy. Cytoplasmic contents including protein, mRNA, miRNA, and lipids have all been studied within the exosomal fraction. Many prospective urinary exosomal biomarkers have been successfully identified for a variety of kidney or genitourinary tract conditions; detection of systemic conditions may also be possible. Isolation and analysis of exosomes can be achieved by several approaches, although many require specialized equipment or involve lengthy protocols. The need for timely analysis in the clinical setting has driven considerable innovation with several promising options recently emerging. Consensus on exosome isolation, characterization, and normalization procedures would resolve critical clinical translational bottlenecks for existing candidate exosomal biomarkers and provide a template for additional discovery studies. 2017 Published by Elsevier Inc.

  8. Development of rapid urine analysis method for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, J.; Noguchi, H. [Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-05-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  9. Development of rapid urine analysis method for uranium

    International Nuclear Information System (INIS)

    Kuwabara, J.; Noguchi, H.

    2000-01-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  10. Urine Proteomics in the Era of Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ashley Beasley-Green

    2016-11-01

    Full Text Available With the technological advances of mass spectrometry (MS-based platforms, clinical proteomics is one of the most rapidly growing areas in biomedical research. Urine proteomics has become a popular subdiscipline of clinical proteomics because it is an ideal source for the discovery of noninvasive disease biomarkers. The urine proteome offers a comprehensive view of the local and systemic physiology since the proteome is primarily composed of proteins/peptides from the kidneys and plasma. The emergence of MS-based proteomic platforms as prominent bioanalytical tools in clinical applications has enhanced the identification of protein-based urinary biomarkers. This review highlights the characteristics of urine that make it an attractive biofluid for biomarker discovery and the impact of MS-based technologies on the clinical assessment of urinary protein biomarkers.

  11. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  12. A low-noise measurement system for scanning thermal microscopy resistive nanoprobes based on a transformer ratio-arm bridge

    Science.gov (United States)

    Świątkowski, Michał; Wojtuś, Arkadiusz; Wielgoszewski, Grzegorz; Rudek, Maciej; Piasecki, Tomasz; Jóźwiak, Grzegorz; Gotszalk, Teodor

    2018-04-01

    Atomic force microscopy (AFM) is a widely used technology for the investigation and characterization of nanomaterials. Its functionality can be easily expanded by applying dedicated extension modules, which can measure the electrical conductivity or temperature of a sample. In this paper, we introduce a transformer ratio-arm bridge setup dedicated to AFM-based thermal imaging. One of the key features of the thermal module is the use of a low-power driving signal that prevents undesirable tip heating during resistance measurement, while the other is the sensor location in a ratio-arm transformer bridge working in the audio frequency range and ensuring galvanic isolation of the tip, enabling contact-mode scanning of electronic circuits. The proposed expansion module is compact and it can be integrated onto the AFM head close to the cantilever. The calibration process and the resolution of 11 mK of the proposed setup are shown.

  13. Development of a combined rotation anisotropy SHG, laser scanning and interferometric SHG microscopy system for material investigations

    International Nuclear Information System (INIS)

    Prylepa, A.

    2015-01-01

    This thesis presents the enhancement of advanced methods of nonlinear optics and their experimental implementation, in particular for optical second harmonic generation (SHG), and the results of further non-destructive investigations of the surfaces and interface structures of various materials by means of these methods. According to the phenomenological theory, SHG process is forbidden in a bulk of centrosymmetric media in dipole approximation. Thereby, main sources of SHG response are localised in the regions of material where centrosymmetry is broken, in the first place these are surfaces and interfaces. Therefore, the SHG process is highly sensitive to the properties of the surfaces and interfaces of centrosymmetric media that makes SHG an attractive tool for the investigation of materials. In our work, we focused on the experimental implementation and improvement of the following techniques of SHG analysis: rotation anisotropy SHG (RA-SHG), laser scanning SHG microscopy (LS-SHGM), and interferometric SHG microscopy (iSHGM). These techniques have unique capabilities, e.g., molecular contrast and polarisation sensitivity, for the non-invasive investigation of materials. Additionally, an optical coherence microscopy (OCM) technique was implemented for the simultaneous coherent detection of the linear optical response. All the mentioned experimental techniques were embedded, without a deterioration of the main possibilities, in one combined experimental setup providing simultaneous detection of linear and nonlinear optical responses. It should be noted that as a main light source we used a broadband (62 nm) femtosecond fiber laser working at central wavelength of 1560 nm, since such a light source allows to obtain a deeper penetration as compared to the light sources in the visible range penetration depth of more than 200 µm was easily achieved). We would like to underline that such a combined low-coherence iSHGM and OCM setup at the central fundamental

  14. Correlated Light Microscopy and Electron Microscopy

    NARCIS (Netherlands)

    Sjollema, Klaas A.; Schnell, Ulrike; Kuipers, Jeroen; Kalicharan, Ruby; Giepmans, Ben N. G.; MullerReichert, T; Verkade, P

    2012-01-01

    Understanding where, when, and how biomolecules (inter)act is crucial to uncover fundamental mechanisms in cell biology. Recent developments in fluorescence light microscopy (FLM) allow protein imaging in living cells and at the near molecular level. However, fluorescence microscopy only reveals

  15. Crystallization of calcium oxalate in minimally diluted urine

    Science.gov (United States)

    Bretherton, T.; Rodgers, A.

    1998-09-01

    Crystallization of calcium oxalate was studied in minimally diluted (92%) urine using a mixed suspension mixed product crystallizer in series with a Malvern particle sizer. The crystallization was initiated by constant flow of aqueous sodium oxalate and urine into the reaction vessel via two independent feed lines. Because the Malvern cell was in series with the reaction vessel, noninvasive measurement of particle sizes could be effected. In addition, aliquots of the mixed suspension were withdrawn and transferred to a Coulter counter for crystal counting and sizing. Steady-state particle size distributions were used to determine nucleation and growth kinetics while scanning electron microscopy was used to examine deposited crystals. Two sets of experiments were performed. In the first, the effect of the concentration of the exogenous sodium oxalate was investigated while in the second, the effect of temperature was studied. Calcium oxalate nucleation and growth rates were found to be dependent on supersaturation levels inside the crystallizer. However, while growth rate increased with increasing temperature, nucleation rates decreased. The favored phases were the trihydrate at 18°C, the dihydrate at 38° and the monohydrate at 58°C. The results of both experiments are in agreement with those obtained in other studies that have been conducted in synthetic and in maximally diluted urine and which have employed invasive crystal counting and sizing techniques. As such, the present study lends confidence to the models of urinary calcium oxalate crystallization processes which currently prevail in the literature.

  16. The optical nature of methylsuccinic acid in human urine

    Science.gov (United States)

    Zeitman, B.; Lawless, J. G.

    1975-01-01

    Methylsuccinic acid was isolated from human urine, derivatized as the di-S-(+)-2-butyl ester, and analyzed using a gas chromatographic system capable of separating the enantiomers of the derivative. The R-(+)-isomer was found to be present. Methylsuccinic acid is potentially important as a criterion for abiogenicity, having been obtained as a racemic mixture from sources known to be abiotic.

  17. Green Urine in Traditional Persian Medicine

    Science.gov (United States)

    Kolouri, Sepideh; Daneshfard, Babak; Jaladat, Amir-Mohammad; Tafazoli, Vahid

    2016-01-01

    The color of urine is an important factor in urine examination, which can help physicians differentiate various diseases. Today, it is known that certain dyes, drug intoxications, and diseases can induce green urine discoloration. In the view of traditional Persian medicine, which is based on humoral medicine, green urine discoloration is generally referred to the dominance of coldness in the body. In fact, it is considered to be a result of a special kind of humoral imbalance and fluid depletion or retention in the human body. Persian scholars believed that green urine could be an indicator of intoxication or a predictor of an imminent spasm or convulsion in pediatric patients. Further investigations could result in finding new diagnostic scales of urine color based on the teachings of traditional Persian medicine. PMID:27103627

  18. Fluorescence confocal microscopy for pathologists.

    Science.gov (United States)

    Ragazzi, Moira; Piana, Simonetta; Longo, Caterina; Castagnetti, Fabio; Foroni, Monica; Ferrari, Guglielmo; Gardini, Giorgio; Pellacani, Giovanni

    2014-03-01

    Confocal microscopy is a non-invasive method of optical imaging that may provide microscopic images of untreated tissue that correspond almost perfectly to hematoxylin- and eosin-stained slides. Nowadays, following two confocal imaging systems are available: (1) reflectance confocal microscopy, based on the natural differences in refractive indices of subcellular structures within the tissues; (2) fluorescence confocal microscopy, based on the use of fluorochromes, such as acridine orange, to increase the contrast epithelium-stroma. In clinical practice to date, confocal microscopy has been used with the goal of obviating the need for excision biopsies, thereby reducing the need for pathological examination. The aim of our study was to test fluorescence confocal microscopy on different types of surgical specimens, specifically breast, lymph node, thyroid, and colon. The confocal images were correlated to the corresponding histological sections in order to provide a morphologic parallel and to highlight current limitations and possible applications of this technology for surgical pathology practice. As a result, neoplastic tissues were easily distinguishable from normal structures and reactive processes such as fibrosis; the use of fluorescence enhanced contrast and image quality in confocal microscopy without compromising final histologic evaluation. Finally, the fluorescence confocal microscopy images of the adipose tissue were as accurate as those of conventional histology and were devoid of the frozen-section-related artefacts that can compromise intraoperative evaluation. Despite some limitations mainly related to black/white images, which require training in imaging interpretation, this study confirms that fluorescence confocal microscopy may represent an alternative to frozen sections in the assessment of margin status in selected settings or when the conservation of the specimen is crucial. This is the first study to employ fluorescent confocal microscopy on

  19. Urine Bag as a Modern Day Matula

    OpenAIRE

    Viswanathan, Stalin

    2013-01-01

    Since time immemorial uroscopic analysis has been a staple of diagnostic medicine. It received prominence during the middle ages with the introduction of the matula. Urinary discoloration is generally due to changes in urochrome concentration associated with the presence of other endogenous or exogenous pigments. Observation of urine colors has received less attention due to the advances made in urinalysis. A gamut of urine colors can be seen in urine bags of hospitalized patients that may gi...

  20. Radioimmunoassay of triiodothyronine in urine

    International Nuclear Information System (INIS)

    Kosowicz, J.; Gembicki, M.; Schneider, E.; Eder, M.

    1977-01-01

    In 21 cases of hypothyroidism, in 39 cases of hyperthyroidism, in 54 healthy subjects, in 23 pregnant women, and in certain internal diseases determinations of triiodothyronine were carried out in urine by radioimmunoassay. Anti-T 3 antibodies were obtained in rabbits and sheep immunized with a complex of bovine albumin with triiodothyronine ester. Labelled triiodothyronine of high specific activity was obtained by iodinating triodothyronine by the chloramine method. Determinations of triiodothyronine were performed in morning urine and the obtained values were calculated for one-hour excretion. In healthy subjects the excretion of T 3 was from 20 to 95 ng/hour, in hyperthyroidism it was significantly raised to from 120 to over 600 ng/hour, while in most cases of hypothyroidism it was decreased. In pregnancy the urinary excretion of T 3 was normal amounting to from 34 to 87 ng/hour, although in most cases the serum T 3 concentration was raised. In cases of anorexia nervosa and in obese starving subjects the excretion of T 3 fell significantly, and similarly low excretion was found in some cases of debilitating diseases and myocardial infarction. (author)

  1. Microsphere imaging with confocal microscopy and two photon microscopy

    International Nuclear Information System (INIS)

    Chun, Hyung Su; An, Kyung Won; Lee, Jai Hyung

    2002-01-01

    We have acquired images of polystyrene and fused-silica microsphere by using conventional optical microscopy, confocal microscopy and two-photon microscopy, and performed comparative analysis of these images. Different from conventional optical microscopy, confocal and two-photon microscopy had good optical sectioning capability. In addition, confocal microscopy and two-photon microscopy had better lateral resolution than conventional optical microscopy. These results are attributed to confocality and nonlinearity of confocal microscopy and two photon microscopy, respectively.

  2. Comparison of tissue damage caused by various laser systems with tissue tolerable plasma by light and laser scan microscopy

    International Nuclear Information System (INIS)

    Vandersee, Staffan; Lademann, Jürgen; Richter, Heike; Patzelt, Alexa; Lange-Asschenfeldt, Bernhard

    2013-01-01

    Tissue tolerable plasma (TTP) represents a novel therapeutic method with promising capabilities in the field of dermatological interventions, in particular disinfection but also wound antisepsis and regeneration. The energy transfer by plasma into living tissue is not easily educible, as a variety of features such as the medium’s actual molecule-stream, the ions, electrons and free radicals involved, as well as the emission of ultraviolet, visible and infrared light contribute to its increasingly well characterized effects. Thus, relating possible adversary effects, especially of prolonged exposure to a single component of the plasma’s mode of action, is difficult. Until now, severe adverse events connected to plasma exposure have not been reported when conducted according to existing therapeutic protocols. In this study, we have compared the tissue damage-potential of CO 2 and dye lasers with TTP in a porcine model. After exposure of pig ear skin to the three treatment modalities, all specimens were examined histologically and by means of laser scan microscopy (LSM). Light microscopical tissue damage could only be shown in the case of the CO 2 laser, whereas dye laser and plasma treatment resulted in no detectable impairment of the specimens. In the case of TTP, LSM examination revealed only an impairment of the uppermost corneal layers of the skin, thus stressing its safety when used in vivo. (letter)

  3. Scanning Hall-probe microscopy system for two-dimensional imaging of critical current density in RE-123 coated conductors

    International Nuclear Information System (INIS)

    Higashikawa, K.; Inoue, M.; Kawaguchi, T.; Shiohara, K.; Imamura, K.; Kiss, T.; Iijima, Y.; Kakimoto, K.; Saitoh, T.; Izumi, T.

    2011-01-01

    Nondestructive characterization method of in-plane distribution of critical current density for coated conductors. Current distribution in a coated conductor compared with that from theoretical analysis. Relationship between local critical current density and local magnetic field. We have developed a characterization method for two-dimensional imaging of critical current density in coated conductors (CCs) based on scanning Hall-probe microscopy (SHPM). The distributions of the magnetic field around a sample were measured for several different conditions of external magnetic fields, and then were converted to those of the sheet current density which flowed to shield the external magnetic field or to trap the penetrated magnetic field. As a result, it was found that the amplitude of the sheet current density corresponded to that of critical current density almost in all the area of the sample except for the region where current direction changed. This indicates that we could obtain an in-plane distribution of the critical current density with a spatial resolution of around 100 μm in non-destructive manner by this method. We believe that this measurement will be a multifunctional and comprehensive characterization method for coated conductors.

  4. Electron microscopy for Engineers

    International Nuclear Information System (INIS)

    Jones, I P

    2009-01-01

    This paper reviews the application of (mainly) Transmission Electron Microscopy (TEM) in an engineering context. The first two sections are TEM and chemical in nature; the final three sections are more general and include aspects of Scanning Electron Microscopy (SEM).

  5. Electron microscopy of surfaces

    International Nuclear Information System (INIS)

    Venables, J.A.

    1981-01-01

    Electron beam techniques used to study clean surfaces and surface processes on a microscopic scale are reviewed. Recent experimental examples and possible future developments are discussed. Special emphasis is given to (i) transmission diffraction and microscopy techniques, including atomic imaging; (ii) Auger microscopy on bulk and thin film samples; (iii) secondary electron microscopy, especially low energy secondaries for work-function imaging and photoelectron imaging; and (iv) reflection electron microscopy and diffraction. (orig.)

  6. The Urine Marker Test: An Alternative Approach to Supervised Urine Collection for Doping Control.

    Science.gov (United States)

    Elbe, Anne-Marie; Jensen, Stine Nylansted; Elsborg, Peter; Wetzke, Monika; Woldemariam, Getachew A; Huppertz, Bernd; Keller, Ruprecht; Butch, Anthony W

    2016-01-01

    Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. The objective of this study was to investigate the use of the urine marker during urine doping control testing. Two studies investigated athletes' acceptance of this new method via two questionnaires (n = 253). Furthermore, a third study (n = 91) investigated whether ingestion of the marker can identify the urine as coming from a specific person and whether the marker interferes with the detection of prohibited substances. The results indicate that this new method finds wide acceptance both from athletes who have only heard about the procedure and those who have actually tested the new method. Furthermore, the marker, which can identify urine as coming from a specific person, does not interfere with the detection of prohibited substances.

  7. A machine vision system for automated non-invasive assessment of cell viability via dark field microscopy, wavelet feature selection and classification

    Directory of Open Access Journals (Sweden)

    Friehs Karl

    2008-10-01

    Full Text Available Abstract Background Cell viability is one of the basic properties indicating the physiological state of the cell, thus, it has long been one of the major considerations in biotechnological applications. Conventional methods for extracting information about cell viability usually need reagents to be applied on the targeted cells. These reagent-based techniques are reliable and versatile, however, some of them might be invasive and even toxic to the target cells. In support of automated noninvasive assessment of cell viability, a machine vision system has been developed. Results This system is based on supervised learning technique. It learns from images of certain kinds of cell populations and trains some classifiers. These trained classifiers are then employed to evaluate the images of given cell populations obtained via dark field microscopy. Wavelet decomposition is performed on the cell images. Energy and entropy are computed for each wavelet subimage as features. A feature selection algorithm is implemented to achieve better performance. Correlation between the results from the machine vision system and commonly accepted gold standards becomes stronger if wavelet features are utilized. The best performance is achieved with a selected subset of wavelet features. Conclusion The machine vision system based on dark field microscopy in conjugation with supervised machine learning and wavelet feature selection automates the cell viability assessment, and yields comparable results to commonly accepted methods. Wavelet features are found to be suitable to describe the discriminative properties of the live and dead cells in viability classification. According to the analysis, live cells exhibit morphologically more details and are intracellularly more organized than dead ones, which display more homogeneous and diffuse gray values throughout the cells. Feature selection increases the system's performance. The reason lies in the fact that feature

  8. Dictionary of Microscopy

    Science.gov (United States)

    Heath, Julian

    2005-10-01

    The past decade has seen huge advances in the application of microscopy in all areas of science. This welcome development in microscopy has been paralleled by an expansion of the vocabulary of technical terms used in microscopy: terms have been coined for new instruments and techniques and, as microscopes reach even higher resolution, the use of terms that relate to the optical and physical principles underpinning microscopy is now commonplace. The Dictionary of Microscopy was compiled to meet this challenge and provides concise definitions of over 2,500 terms used in the fields of light microscopy, electron microscopy, scanning probe microscopy, x-ray microscopy and related techniques. Written by Dr Julian P. Heath, Editor of Microscopy and Analysis, the dictionary is intended to provide easy navigation through the microscopy terminology and to be a first point of reference for definitions of new and established terms. The Dictionary of Microscopy is an essential, accessible resource for: students who are new to the field and are learning about microscopes equipment purchasers who want an explanation of the terms used in manufacturers' literature scientists who are considering using a new microscopical technique experienced microscopists as an aide mémoire or quick source of reference librarians, the press and marketing personnel who require definitions for technical reports.

  9. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test (Video) Print en español Obtención de un análisis de orina (video) It ...

  10. Odors from evaporation of acidified pig urine

    NARCIS (Netherlands)

    Willers, H.C.; Hobbs, P.J.; Ogink, N.W.M.

    2004-01-01

    In the Dutch Hercules project feces and urine from pigs are collected separately underneath the slatted floor in a pig house and treated in two processes. Feces are composted and urine is concentrated by water evaporation in a packed bed. Exhaust air from the pig house is used for the evaporation in

  11. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... site Sitio para adolescentes Body Mind Sexual Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test ( ...

  12. The determination of 210Po in urine

    International Nuclear Information System (INIS)

    Bale, W.F.; Helmkamp, R.W.; Hrynyszyn, V.; Contreras, M.A.

    1975-01-01

    To measure 210 Po present in normal human urine a technique was developed in which a 4.5 x 11cm silver foil was shaken at room temperature for 48-hr periods in each of two successive volumes of 1.7 l. of urine acidified to 0.5N with HCl. Alpha rays were counted with an ionization chamber, coupled to a vibrating reed electrometer, and capable of measuring α-ray pulses originating on both sides of the silver foil serving as a central electrode. The background α-count was less than 2/hr. Analyses of human urine spiked with 0.29 to 0.58pCi of 210 Po, together with studies of urine from dogs carrying significant body burdens of 210 Pb, indicated that the average recovery of added 210 Po from 1.7 l. volumes of spiked human urine was 72%. If it is assumed that the same percentage of 210 Po is extracted from non-spiked urine, then the average 210 Po concentration found in 13 analyses of 2 x 1.7 l. samples from 26 different pools of fresh human urine was 0.023pCi/l. Substantial additional 210 Po was generated on short aging of the urine through radioactive decay of excreted 210 Bi. (author)

  13. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Español Getting a Urine Test (Video) KidsHealth / For Kids / Getting a Urine Test (Video) Print en español ...

  14. Recreational drug use at a major music festival: trend analysis of anonymised pooled urine

    DEFF Research Database (Denmark)

    Hoegberg, Lotte Christine Groth; Christiansen, Cecilie; Soe, Jesper

    2018-01-01

    of recreational drugs used and NPS available in Denmark is limited as identification is possible only when consumers become patients in the healthcare system or through drug seizures. We aimed to detect classical recreational drugs and NPS in the urine of music festival attendees and evaluate if the use of NPS...... could have been predicted by comparing study data with drug seizure data from the previous year published by European and Danish health authorities.Methods: In a cross-sectional study, 44 urine samples were collected from three urinals at Roskilde Festival 2016—the largest Danish music festival. Two...... urinals were placed at music stages with late-night concerts, and one urinal was placed at a camp site. Samples were prepared using enzymatic hydrolysis followed by cationic and anionic solid phase extraction, and analysed using ultra performance liquid chromatography-high-resolution time-of-flight mass...

  15. Studies on urine treatment by biological purification using Azolla and UV photocatalytic oxidation

    Science.gov (United States)

    Liu, Xiaofeng; Chen, Min; Bian, Zuliang; Liu, Chung-Chu

    The amount of water consumed in space station operations is very large. In order to reduce the amount of water which must be resupplied from Earth, the space station needs to resolve the problems of water supply. For this reason, the recovery, regeneration and utilization of urine of astronauts are of key importance. Many investigations on this subject have been reported. Our research is based on biological absorption and, purification using UV photocatalytic oxidation techniques to achieve comprehensive treatment for urine. In the treatment apparatus we created, the urine solution is used as part of the nutrient solution for the biological components in our bioregenerative life support system. After being absorbed, the nutrients from the urine were then decomposed, metabolized and purified which creates a favorable condition for the follow-up oxidation treatment by UV photocatalytic oxidation. After these two processes, the treated urine solution reached Chinese national standards for drinking water quality (GB5749-1985).

  16. Size-dependent redox behavior of iron observed by in-situ single nanoparticle spectro-microscopy on well-defined model systems.

    Science.gov (United States)

    Karim, Waiz; Kleibert, Armin; Hartfelder, Urs; Balan, Ana; Gobrecht, Jens; van Bokhoven, Jeroen A; Ekinci, Yasin

    2016-01-06

    Understanding the chemistry of nanoparticles is crucial in many applications. Their synthesis in a controlled manner and their characterization at the single particle level is essential to gain deeper insight into chemical mechanisms. In this work, single nanoparticle spectro-microscopy with top-down nanofabrication is demonstrated to study individual iron nanoparticles of nine different lateral dimensions from 80 nm down to 6 nm. The particles are probed simultaneously, under same conditions, during in-situ redox reaction using X-ray photoemission electron microscopy elucidating the size effect during the early stage of oxidation, yielding time-dependent evolution of iron oxides and the mechanism for the inter-conversion of oxides in nanoparticles. Fabrication of well-defined system followed by visualization and investigation of singled-out particles eliminates the ambiguities emerging from dispersed nanoparticles and reveals a significant increase in the initial rate of oxidation with decreasing size, but the reactivity per active site basis and the intrinsic chemical properties in the particles remain the same in the scale of interest. This advance of nanopatterning together with spatially-resolved single nanoparticle X-ray absorption spectroscopy will guide future discourse in understanding the impact of confinement of metal nanoparticles and pave way to solve fundamental questions in material science, chemical physics, magnetism, nanomedicine and nanocatalysis.

  17. Size-dependent redox behavior of iron observed by in-situ single nanoparticle spectro-microscopy on well-defined model systems

    Science.gov (United States)

    Karim, Waiz; Kleibert, Armin; Hartfelder, Urs; Balan, Ana; Gobrecht, Jens; van Bokhoven, Jeroen A.; Ekinci, Yasin

    2016-01-01

    Understanding the chemistry of nanoparticles is crucial in many applications. Their synthesis in a controlled manner and their characterization at the single particle level is essential to gain deeper insight into chemical mechanisms. In this work, single nanoparticle spectro-microscopy with top-down nanofabrication is demonstrated to study individual iron nanoparticles of nine different lateral dimensions from 80 nm down to 6 nm. The particles are probed simultaneously, under same conditions, during in-situ redox reaction using X-ray photoemission electron microscopy elucidating the size effect during the early stage of oxidation, yielding time-dependent evolution of iron oxides and the mechanism for the inter-conversion of oxides in nanoparticles. Fabrication of well-defined system followed by visualization and investigation of singled-out particles eliminates the ambiguities emerging from dispersed nanoparticles and reveals a significant increase in the initial rate of oxidation with decreasing size, but the reactivity per active site basis and the intrinsic chemical properties in the particles remain the same in the scale of interest. This advance of nanopatterning together with spatially-resolved single nanoparticle X-ray absorption spectroscopy will guide future discourse in understanding the impact of confinement of metal nanoparticles and pave way to solve fundamental questions in material science, chemical physics, magnetism, nanomedicine and nanocatalysis.

  18. Three-dimensional motion-picture imaging of dynamic object by parallel-phase-shifting digital holographic microscopy using an inverted magnification optical system

    Science.gov (United States)

    Fukuda, Takahito; Shinomura, Masato; Xia, Peng; Awatsuji, Yasuhiro; Nishio, Kenzo; Matoba, Osamu

    2017-04-01

    We constructed a parallel-phase-shifting digital holographic microscopy (PPSDHM) system using an inverted magnification optical system, and succeeded in three-dimensional (3D) motion-picture imaging for 3D displacement of a microscopic object. In the PPSDHM system, the inverted and afocal magnification optical system consisted of a microscope objective (16.56 mm focal length and 0.25 numerical aperture) and a convex lens (300 mm focal length and 82 mm aperture diameter). A polarization-imaging camera was used to record multiple phase-shifted holograms with a single-shot exposure. We recorded an alum crystal, sinking down in aqueous solution of alum, by the constructed PPSDHM system at 60 frames/s for about 20 s and reconstructed high-quality 3D motion-picture image of the crystal. Then, we calculated amounts of displacement of the crystal from the amounts in the focus plane and the magnifications of the magnification optical system, and obtained the 3D trajectory of the crystal by that amounts.

  19. Radioimmunoassay of antidiuretic hormone in human urine. Applications

    International Nuclear Information System (INIS)

    Zebidi, Abdelkrim.

    1977-10-01

    This work is devoted mainly to the development of a radioimmunological system of antidiuretic hormone (ADH) determination in the urine and its physiological and pathological applications. The radioimmunological method thus replaces the biological measurement of antidiuretic hormone in the urine. This new technique was not possible until specific arginine vasopressin antibodies were obtained and a labelled hormone was prepared according to the criteria set for a radioimmunoassay. The labelled hormone is lysine vasopressin (greater stability). Although 125 I-LVP has lost most of its biological activity the molecule keeps all its immunological properties, behaving in the same way as non-iodinated synthetic LVP towards anti-LVP antibodies. Once specific antivasopressin antibodies and immunologically competent labelled hormone were available, conditions were defined for the radioimmunological ADH test in the urine. This technique, relatively easy to use, allows twenty samples to be measured simultaneously. With this sensitive, specific and reproducible method, it is thus possible to estimate the urinary ADH excretion rates from a 20 ml volume of urine after previous extraction on amberlite CG 50. This extraction method is aimed at both concentrating the hormone and eliminating non-specific interferences. The hormone extraction yield is about 92%+-8 [fr

  20. Accuracy of two digital implant impression systems based on confocal microscopy with variations in customized software and clinical parameters.

    Science.gov (United States)

    Giménez, Beatriz; Pradíes, Guillermo; Martínez-Rus, Francisco; Özcan, Mutlu

    2015-01-01

    To evaluate the accuracy of two digital impression systems based on the same technology but different postprocessing correction modes of customized software, with consideration of several clinical parameters. A maxillary master model with six implants located in the second molar, second premolar, and lateral incisor positions was fitted with six cylindrical scan bodies. Scan bodies were placed at different angulations or depths apical to the gingiva. Two experienced and two inexperienced operators performed scans with either 3D Progress (MHT) or ZFX Intrascan (Zimmer Dental). Five different distances between implants (scan bodies) were measured, yielding five data points per impression and 100 per impression system. Measurements made with a high-accuracy three-dimensional coordinate measuring machine (CMM) of the master model acted as the true values. The values obtained from the digital impressions were subtracted from the CMM values to identify the deviations. The differences between experienced and inexperienced operators and implant angulation and depth were compared statistically. Experience of the operator, implant angulation, and implant depth were not associated with significant differences in deviation from the true values with both 3D Progress and ZFX Intrascan. Accuracy in the first scanned quadrant was significantly better with 3D Progress, but ZFX Intrascan presented better accuracy in the full arch. Neither of the two systems tested would be suitable for digital impression of multiple-implant prostheses. Because of the errors, further development of both systems is required.

  1. Protein in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... this page: https://medlineplus.gov/labtests/proteininurine.html Protein in Urine To use the sharing features on this page, please enable JavaScript. What is a Protein in Urine Test? A protein in urine test ...

  2. Ethanol Induced Urine Acidification is Related with Early Acetaldehyde Concentration

    Directory of Open Access Journals (Sweden)

    Soon Kil Kwon

    2014-06-01

    Conclusion: In conclusion, urine acidification after ethanol ingestion is related with serum acetaldehyde concentration. Early elevation of acetaldhyde could induce urine acidification, but the urine pH was elevated after a few hours, that might make prolonged acidemia.

  3. A new data acquisition and imaging system for nuclear microscopy based on a Field Programmable Gate Array card

    International Nuclear Information System (INIS)

    Bettiol, A.A.; Udalagama, C.; Watt, F.

    2009-01-01

    The introduction of the new Field Programmable Gate Array (FPGA) cards by National Instruments has made it possible for the first time to develop reconfigurable custom data acquisition hardware easily with the LabVIEW programming environment. Data acquisition issues such as precise timing for scanning and operating system latencies can now be easily overcome using this new technology because the data acquisition software is embedded in the FPGA chip on the card. In this paper we present the first results of the new data acquisition system developed at the Centre for Ion Beam Applications (CIBA), National University of Singapore using the new National Instruments cards in conjunction with rack mountable Wilkinson type ADCs.

  4. The method of segmentation of leukocytes in information-measuring systems on the basis of light microscopy

    Science.gov (United States)

    Nikitaev, V. G.; Pronichev, A. N.; Polyakov, E. V.; Zaharenko, Yu V.

    2018-01-01

    The paper considers the problem of leukocytes segmentation in microscopic images of bone marrow smears for automated diagnosis of the blood system diseases. The method was proposed to solve the problem of segmentation of contacting leukocytes in images of bone marrow smears. The method is based on the analysis of structure of objects of a separation and distances filter in combination with the watershed method and distance transformation method.

  5. In situ and ex situ electron microscopy and X-ray diffraction characterization of the evolution of a catalytic system - from synthesis to deactivation

    DEFF Research Database (Denmark)

    Gardini, Diego

    Heterogeneous catalysis represents a research field of undeniable importance for a multitude of technological and industrial processes. Supported catalysts are nowadays at the base of the large-scale production of most chemicals and are used for the removal of air pollutants from automotive engines...... the understanding of the structural properties and mechanisms at the origin of catalytic activity. This thesis presents the potential and uniqueness of ex situ and in situ transmission electron microscopy (TEM) and X-ray diffraction (XRD) techniques in the characterization of several supported material systems...... TEM (HRTEM) and electron energy loss spectroscopy (EELS) revealed the degradation of the supported carbide particles probably due to the formation of volatile molybdenum hydroxide species. The activity of silver nanoparticles as catalyst for soot oxidation was studied in operative conditions...

  6. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    Science.gov (United States)

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  7. Urine: Waste product or biologically active tissue?

    Science.gov (United States)

    2018-03-01

    Historically, urine has been viewed primarily as a waste product with little biological role in the overall health of an individual. Increasingly, data suggest that urine plays a role in human health beyond waste excretion. For example, urine might act as an irritant and contribute to symptoms through interaction with-and potential compromise of-the urothelium. To explore the concept that urine may be a vehicle for agents with potential or occult bioactivity and to discuss existing evidence and novel research questions that may yield insight into such a role, the National Institute of Diabetes and Digestive and Kidney Disease invited experts in the fields of comparative evolutionary physiology, basic science, nephrology, urology, pediatrics, metabolomics, and proteomics (among others) to a Urinology Think Tank meeting on February 9, 2015. This report reflects ideas that evolved from this meeting and current literature, including the concept of urine quality, the biological, chemical, and physical characteristics of urine, including the microbiota, cells, exosomes, pH, metabolites, proteins, and specific gravity (among others). Additionally, the manuscript presents speculative, and hopefully testable, ideas about the functional roles of urine constituents in health and disease. Moving forward, there are several questions that need further understanding and pursuit. There were suggestions to consider actively using various animal models and their biological specimens to elaborate on basic mechanistic information regarding human bladder dysfunction. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  8. Preparation of a molecularly imprinted sensor based on quartz crystal microbalance for specific recognition of sialic acid in human urine.

    Science.gov (United States)

    Qiu, Xiuzhen; Xu, Xian-Yan; Chen, Xuncai; Wu, Yiyong; Guo, Huishi

    2018-05-08

    A novel molecularly imprinted quartz crystal microbalance (QCM) sensor was successfully prepared for selective determination of sialic acid (SA) in human urine samples. To obtain the QCM sensor, we first modified the gold surface of the QCM chip by self-assembling of allylmercaptane to introduce polymerizable double bonds on the chip surface. Then, SA molecularly imprinted polymer (MIP) nanofilm was attached to the modified QCM chip surface. For comparison, we have also characterized the nonmodified and improved surfaces of the QCM sensor by using atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectroscopy. We then tested the selectivity and detection limit of the imprinted QCM sensor via a series of adsorption experiments. The results show a linear response in the range of 0.025-0.50 μmol L -1 for sialic acid. Moreover, the limit of detection (LOD) of the prepared imprinted QCM sensor was found to be 1.0 nmol L -1 for sialic acid, and high recovery values range from 87.6 to 108.5% with RSD sensor was developed and used to detect sialic acid in human urine samples. Graphical abstract Specific recognition of sialic acid by the MIP-QCM sensor system.

  9. Microscopy and Image Analysis.

    Science.gov (United States)

    McNamara, George; Difilippantonio, Michael; Ried, Thomas; Bieber, Frederick R

    2017-07-11

    This unit provides an overview of light microscopy, including objectives, light sources, filters, film, and color photography for fluorescence microscopy and fluorescence in situ hybridization (FISH). We believe there are excellent opportunities for cytogeneticists, pathologists, and other biomedical readers, to take advantage of specimen optical clearing techniques and expansion microscopy-we briefly point to these new opportunities. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  10. CARS microscopy for imaging

    International Nuclear Information System (INIS)

    Arzumanyan Grigory; Voskanyan Karine

    2013-01-01

    Optical microscopy grows in its importance with the development of modern nanotechnology, biotechnology, methods of diagnostics and treatment of most dangerous diseases for mankind. There are several important goals of optical microscopy for biomedical studies among which the next three may be distinguished: fast imaging with high lateral spatial resolution, 3-D sectioning capability and high contrast for chemical selectivity. To meet these specific requirements, various types of both linear and nonlinear optical microscopy were elaborated. (authors)

  11. Fluorescence (Multiwave) Confocal Microscopy.

    Science.gov (United States)

    Welzel, J; Kästle, Raphaela; Sattler, Elke C

    2016-10-01

    In addition to reflectance confocal microscopy, multiwave confocal microscopes with different laser wavelengths in combination with exogenous fluorophores allow fluorescence mode confocal microscopy in vivo and ex vivo. Fluorescence mode confocal microscopy improves the contrast between the epithelium and the surrounding soft tissue and allows the depiction of certain structures, like epithelial tumors, nerves, and glands. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Feline urine metabolomic signature: characterization of low-molecular-weight substances in urine from domestic cats.

    Science.gov (United States)

    Rivera-Vélez, Sol-Maiam; Villarino, Nicolas F

    2018-02-01

    Objectives This aim of this study was to characterize the composition and content of the feline urine metabolome. Methods Eight healthy domestic cats were acclimated at least 10 days before starting the study. Urine samples (~2 ml) were collected by ultrasound-guided cystocentesis. Samples were centrifuged at 1000 × g for 8 mins, and the supernatant was analyzed by gas chromatography/time-of-flight mass spectrometery. The urine metabolome was characterized using an untargeted metabolomics approach. Results Three hundred and eighteen metabolites were detected in the urine of the eight cats. These molecules are key components of at least 100 metabolic pathways. Feline urine appears to be dominated by carbohydrates, carbohydrate conjugates, organic acid and derivatives, and amino acids and analogs. The five most abundant molecules were phenaceturic acid, hippuric acid, pseudouridine phosphate and 3-(4-hydroxyphenyl) propionic acid. Conclusions and relevance This study is the first to characterize the feline urine metabolome. The results of this study revealed the presence of multiple low-molecular-weight substances that were not known to be present in feline urine. As expected, the origin of the metabolites detected in urine was diverse, including endogenous compounds and molecules biosynthesized by microbes. Also, the diet seemed to have had a relevant role on the urine metabolome. Further exploration of the urine metabolic phenotype will open a window for discovering unknown, or poorly understood, metabolic pathways. In turn, this will advance our understanding of feline biology and lead to new insights in feline physiology, nutrition and medicine.

  13. Electron Microscopy Center (EMC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Electron Microscopy Center (EMC) at Argonne National Laboratory develops and maintains unique capabilities for electron beam characterization and applies those...

  14. Coherent light microscopy

    CERN Document Server

    Ferraro, Pietro; Zalevsky, Zeev

    2011-01-01

    This book deals with the latest achievements in the field of optical coherent microscopy. While many other books exist on microscopy and imaging, this book provides a unique resource dedicated solely to this subject. Similarly, many books describe applications of holography, interferometry and speckle to metrology but do not focus on their use for microscopy. The coherent light microscopy reference provided here does not focus on the experimental mechanics of such techniques but instead is meant to provide a users manual to illustrate the strengths and capabilities of developing techniques. Th

  15. Bridging fluorescence microscopy and electron microscopy

    NARCIS (Netherlands)

    Giepmans, Ben N. G.

    Development of new fluorescent probes and fluorescence microscopes has led to new ways to study cell biology. With the emergence of specialized microscopy units at most universities and research centers, the use of these techniques is well within reach for a broad research community. A major

  16. Urine Pretreatment History and Perspective in NASA Human Spaceflight

    Science.gov (United States)

    Anderson, Molly; Adam, Niklas; Chambers, Antja; Broyan, James

    2015-01-01

    Urine pretreatment is a technology that may seem to have small mass impacts in future spaceflight missions, but can have significant impacts on reliability, life, and performance of the rest of the wastewater management and recovery systems. NASA has experience with several different urine pretreatment systems, including those flow on the space shuttle, evaluated for NASA waste collection systems or used in Russian commodes on ISS, or developed by NASA or industry as alternatives. Each has had unique requirements for shelf life, operational life, and the life or conditions of the stored, treated urine. Each was evaluated under different test conditions depending on mission, and depending on testing experience developed over NASA's history. Those that were flown led to further lessons learned about hardware compatibility and control. As NASA looks forward to human spaceflight missions beyond low Earth orbit, these techniques need to be evaluated in new light. Based on published design reference missions, candidate requirements can be derived for future systems. Initial comparisons between these requirements and previous performance or test results can be performed. In many cases these comparisons reveal data gaps. Successful previous performance is not enough to address current needs.

  17. Morphological characteristics of urine erythrocytes in children with erythrocyturia

    Directory of Open Access Journals (Sweden)

    V.A. Minakova

    2017-09-01

    Full Text Available Background. Nephropathies with erythrocyturia make up about 1/3 of all diseases of the kidneys and the urinary system, and they have some difficulties in differential diagnostics. Quite often, erythrocyturia is the only symptom of these diseases. In connection with this, determination of its origin is an important task in forming the correct diagnosis. Erythrocyturia in most diseases of the lower urinary tract is not accompanied by proteinuria or the presence of cylinders in the urine. The presence of proteinuria (more than 0.3 g/l or 1 g protein in urine per day, along with the appearance of erythrocytic cylinder in the urine sediment, raises suspicion in favor of glomerular or tubular diseases. Glomerular erythrocytes may be detected by means of urea concentration factor (UCF in the urinary sediment as a preliminary test for the determination of the erythrocyturia site. Erythrocytes that pass through the glomerular membrane have a changed form (dysmorphic. Determination of acanthocytes in the urine (ring-shaped erythrocytes with one or several bulges in the form of bubbles of different sizes and types is a more precise criterion of glomerular nephropathy than the presence of dysmorphic erythrocytes. The purpose of the study was to determine the morphological characteristics of urine erythrocytes in children with erythrocyturia, to improve the quality of differential diagnosis. Materials and methods. Determination of the morphological characteristics of urinary erythrocytes using UCF in 73 patients aged 1 to 18 years, of which 45 (61.6 % are patients with hematuric form of glomerulonephritis, 23 (31.5 % — with hereditary nephritis, and 5 (6.8 % — with dysmetabolic nephropathy. Detection of 50 to 80 % of dysmorphic erythrocytes in the urine sediment and finding in urine of more than 5 % of acanthocytes is a highly sensitive and specific diagnostic criterion for glomerular hematuria. Results. In children with a clinical diagnosis

  18. Voltammetric Determination of Thiodiglycolic Acid in Urine

    Czech Academy of Sciences Publication Activity Database

    Dlasková, Z.; Navrátil, Tomáš; Heyrovský, Michael; Pelclová, D.; Novotný, Ladislav

    2003-01-01

    Roč. 375, - (2003), s. 164-168 ISSN 1618-2642 Institutional research plan: CEZ:AV0Z4040901 Keywords : urine * thioglycolic acid * voltammetry Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.715, year: 2003

  19. Urine Albumin and Albumin/ Creatinine Ratio

    Science.gov (United States)

    ... it used? The urine albumin test or albumin/creatinine ratio (ACR) is used to screen people with chronic conditions, such as diabetes and high blood pressure ( hypertension ) that put them at an ...

  20. On-Demand Urine Analyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research program will develop a novel surface-enhanced Raman (SER) sensor that will perform real-time chemical analysis of urine. It...

  1. Kvaliteten af resistensbestemmelser på urin i almen praksis er generelt god

    DEFF Research Database (Denmark)

    Søgaard, Per; Knudsen, Anette Flindt; Højbjerg, Tove

    2012-01-01

    In Denmark, many microbiological tests (microscopy, culture and susceptibility examinations) are done in general practice for the diagnosis of urinary tract infections (UTI). In 2006, the costs of susceptibility examinations were 28 million DKK. Some regional health authorities have established...... a program for quality assessment. National quality requirements for susceptibility examinations have already been established. The clinical microbiological departments send simulated urines with bacteria of common UTI strains. The specimens are examined in general practice with routine methods. The results...

  2. Photodynamic diagnosis of bladder cancer in ex vivo urine cytology

    Science.gov (United States)

    Fu, C. Y.; Ng, B. K.; Razul, S. Gulam; Olivo, Malini C.; Lau, Weber K. O.; Tan, P. H.; Chin, William

    2006-02-01

    Bladder cancer is the fourth common malignant disease worldwide, accounting for 4% of all cancer cases. In Singapore, it is the ninth most common form of cancer. The high mortality rate can be reduced by early treatment following precancerous screening. Currently, the gold standard for screening bladder tumors is histological examination of biopsy specimen, which is both invasive and time-consuming. In this study ex vivo urine fluorescence cytology is investigated to offer a timely and biopsy-free means for detecting bladder cancers. Sediments in patients' urine samples were extracted and incubated with a novel photosensitizer, hypericin. Laser confocal microscopy was used to capture the fluorescence images at an excitation wavelength of 488 nm. Images were subsequently processed to single out the exfoliated bladder cells from the other cells based on the cellular size. Intensity histogram of each targeted cell was plotted and feature vectors, derived from the histogram moments, were used to represent each sample. A difference in the distribution of the feature vectors of normal and low-grade cancerous bladder cells was observed. Diagnostic algorithm for discriminating between normal and low-grade cancerous cells is elucidated in this paper. This study suggests that the fluorescence intensity profiles of hypericin in bladder cells can potentially provide an automated quantitative means of early bladder cancer diagnosis.

  3. Serial-omics characterization of equine urine.

    Directory of Open Access Journals (Sweden)

    Min Yuan

    Full Text Available Horse urine is easily collected and contains molecules readily measurable using mass spectrometry that can be used as biomarkers representative of health, disease or drug tampering. This study aimed at analyzing microliter levels of horse urine to purify, identify and quantify proteins, polar metabolites and non-polar lipids. Urine from a healthy 12 year old quarter horse mare on a diet of grass hay and vitamin/mineral supplements with limited pasture access was collected for serial-omics characterization. The urine was treated with methyl tert-butyl ether (MTBE and methanol to partition into three distinct layers for protein, non-polar lipid and polar metabolite content from a single liquid-liquid extraction and was repeated two times. Each layer was analyzed by high performance liquid chromatography-high resolution tandem mass spectrometry (LC-MS/MS to obtain protein sequence and relative protein levels as well as identify and quantify small polar metabolites and lipids. The results show 46 urine proteins, many related to normal kidney function, structural and circulatory proteins as well as 474 small polar metabolites but only 10 lipid molecules. Metabolites were mostly related to urea cycle and ammonia recycling as well as amino acid related pathways, plant diet specific molecules, etc. The few lipids represented triglycerides and phospholipids. These data show a complete mass spectrometry based-omics characterization of equine urine from a single 333 μL mid-stream urine aliquot. These omics data help serve as a baseline for healthy mare urine composition and the analyses can be used to monitor disease progression, health status, monitor drug use, etc.

  4. Preventing Precipitation in the ISS Urine Processor

    Science.gov (United States)

    Muirhead, Dean; Carter, Layne; Williamson, Jill; Chambers, Antja

    2017-01-01

    The ISS Urine Processor Assembly (UPA) was initially designed to achieve 85% recovery of water from pretreated urine on ISS. Pretreated urine is comprised of crew urine treated with flush water, an oxidant (chromium trioxide), and an inorganic acid (sulfuric acid) to control microbial growth and inhibit precipitation. Unfortunately, initial operation of the UPA on ISS resulted in the precipitation of calcium sulfate at 85% recovery. This occurred because the calcium concentration in the crew urine was elevated in microgravity due to bone loss. The higher calcium concentration precipitated with sulfate from the pretreatment acid, resulting in a failure of the UPA due to the accumulation of solids in the Distillation Assembly. Since this failure, the UPA has been limited to a reduced recovery of water from urine to prevent calcium sulfate from reaching the solubility limit. NASA personnel have worked to identify a solution that would allow the UPA to return to a nominal recovery rate of 85%. This effort has culminated with the development of a pretreatment based on phosphoric acid instead of sulfuric acid. By eliminating the sulfate associated with the pretreatment, the brine can be concentrated to a much higher concentration before calcium sulfate reach the solubility limit. This paper summarizes the development of this pretreatment and the testing performed to verify its implementation on ISS.

  5. An update on purple urine bag syndrome

    Directory of Open Access Journals (Sweden)

    Hadano Y

    2012-08-01

    Full Text Available Yoshiro Hadano,1 Taro Shimizu,2 Shimon Takada,3 Toshiya Inoue,4 Sumire Sorano51Department of General Internal Medicine and Infectious Diseases, Rakuwakai Otowa Hospital, Yamashina-ku, Kyoto, Japan; 2Rollins School of Public Health, Emory University, Atlanta, GA, USA; 3Department of General Internal Medicine, Osaka City General Hospital, Miyakojima-ku, Osaka, Japan; 4Department of Emergency Medicine, Urasoe General Hospital, Urasoe-city, Okinawa, Japan; 5Kobe University School of Medicine, Kusunokicho, Chuoku, Kobe, JapanAbstract: Purple urine bag syndrome is characterized by the urinary drainage bag turning purple in patients on prolonged urinary catheterization, especially those in the bedridden state. It is associated with bacterial urinary tract infections caused by indigo-producing and indirubin-producing bacteria, usually affects women, and is associated with alkaline urine, constipation, and a high bacterial load in the urine. Almost all patients with purple urine bag syndrome are catheterized due to significant disability, and the urinary pH is 7.0 or more. In general, intensive treatment with antibiotics is not recommended. Purple urine bag syndrome per se almost always appears to be asymptomatic and harmless. However, caution is needed, because some cases have been reported to show progression to severe disease states, so further research into the morbidity and mortality of this infection is warranted.Keywords: purple urine, urinary catheterization, geriatrics, urinary tract infection

  6. Pathogens and pharmaceuticals in source-separated urine in eThekwini, South Africa.

    Science.gov (United States)

    Bischel, Heather N; Özel Duygan, Birge D; Strande, Linda; McArdell, Christa S; Udert, Kai M; Kohn, Tamar

    2015-11-15

    In eThekwini, South Africa, the production of agricultural fertilizers from human urine collected from urine-diverting dry toilets is being evaluated at a municipality scale as a way to help finance a decentralized, dry sanitation system. The present study aimed to assess a range of human and environmental health hazards in source-separated urine, which was presumed to be contaminated with feces, by evaluating the presence of human pathogens, pharmaceuticals, and an antibiotic resistance gene. Composite urine samples from households enrolled in a urine collection trial were obtained from urine storage tanks installed in three regions of eThekwini. Polymerase chain reaction (PCR) assays targeted 9 viral and 10 bacterial human pathogens transmitted by the fecal-oral route. The most frequently detected viral pathogens were JC polyomavirus, rotavirus, and human adenovirus in 100%, 34% and 31% of samples, respectively. Aeromonas spp. and Shigella spp. were frequently detected gram negative bacteria, in 94% and 61% of samples, respectively. The gram positive bacterium, Clostridium perfringens, which is known to survive for extended times in urine, was found in 72% of samples. A screening of 41 trace organic compounds in the urine facilitated selection of 12 priority pharmaceuticals for further evaluation. The antibiotics sulfamethoxazole and trimethoprim, which are frequently prescribed as prophylaxis for HIV-positive patients, were detected in 95% and 85% of samples, reaching maximum concentrations of 6800 μg/L and 1280 μg/L, respectively. The antiretroviral drug emtricitabine was also detected in 40% of urine samples. A sulfonamide antibiotic resistance gene (sul1) was detected in 100% of urine samples. By coupling analysis of pathogens and pharmaceuticals in geographically dispersed samples in eThekwini, this study reveals a range of human and environmental health hazards in urine intended for fertilizer production. Collection of urine offers the benefit of

  7. The Accuracy of the Sysmex UF-1000i in Urine Bacterial Detection Compared With the Standard Urine Analysis and Culture.

    Science.gov (United States)

    Erdman, Patrick; Anderson, Brian; Zacko, J Christopher; Taylor, Kirk; Donaldson, Keri

    2017-11-01

    - Urinary tract infections are characterized by the presence of microbial pathogens within the urinary tract. They represent one of the most common infections in hospitalized and clinic patients. - To model the parameters of the Sysmex UF-1000i to the gold standard, urine culture, and to compare the detection of dipstick leukocyte esterase and nitrates to urine cultures and UF-1000i results. - Data were compared from urine samples collected in sterile containers for bacterial culture and microscopic analysis. One sample was used to inoculate a 5% sheep blood agar and MacConkey agar plate using a 0.001-mL calibrated loop. The second sample was analyzed by urinalysis-associated microscopy. The media plates were investigated for growth after 18 to 24 hours of aerobic incubation at 37°C. The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i according to the manufacturer's guidelines. Three definitions for culture results, sensitivity, and specificity at different cutoff values were calculated for the UF-1000i. - The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100 000 or more colony-forming units was 99.3% using the Sysmex UF-1000i. - Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics.

  8. Measurement and application of purine derivatives: Creatinine ratio in spot urine samples of ruminants

    International Nuclear Information System (INIS)

    Chen, X.B.; Jayasuriya, M.C.N.; Makkar, H.P.S.

    2004-01-01

    The daily excretion of purine derivatives in urine has been used to estimate the supply of microbial protein to ruminant animals. The method provides a simple and non-invasive tool to indicate the nutritional status of farm animals. However due to the need for complete collection of urine the potential application at farm level is restricted. Research conducted under the FAO/IAEA Co-ordinated Research Project has indicated that it is possible to use the purine derivatives:creatinine ratio measured in several spot urine samples collected within a day, as an index of microbial protein supply in a banding system for farm application. Some theoretical and experimental aspects in the measurement of purine derivatives:creatinine ratio in spot urine samples and the possible application of the banding system at the farm level are discussed. (author)

  9. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: SPECTROSCOPY

    Science.gov (United States)

    The confocal laser-scanning microscope (CLSM) has enormous potential in many biological fields. The goal of a CLSM is to acquire and quantify fluorescence and in some instruments acquire spectral characterization of emitted signals. The accuracy of these measurements demands that...

  10. Confocal Raman microscopy

    CERN Document Server

    Dieing, Thomas; Hollricher, Olaf

    2018-01-01

    This second edition provides a cutting-edge overview of physical, technical and scientific aspects related to the widely used analytical method of confocal Raman microscopy. The book includes expanded background information and adds insights into how confocal Raman microscopy, especially 3D Raman imaging, can be integrated with other methods to produce a variety of correlative microscopy combinations. The benefits are then demonstrated and supported by numerous examples from the fields of materials science, 2D materials, the life sciences, pharmaceutical research and development, as well as the geosciences.

  11. Persons with Mild or Moderate Alzheimer's Disease Learn to Use Urine Alarms and Prompts to Avoid Large Urinary Accidents

    Science.gov (United States)

    Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Bosco, Andrea; Zonno, Nadia; Badagliacca, Francesco

    2011-01-01

    This study assessed whether three patients with Alzheimer's disease could learn to use urine alarms and caregivers' prompts to eliminate large urinary accidents. As soon as the patient began to release urine, the alarm system presented auditory and vibratory signals. In relation to those signals, the caregiver would prompt/encourage the patient to…

  12. The Determination of Polyethylene Glycol in Untreated Urine Samples by High Performance Liquid Chromatography for Intestinal Permeability Studies

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Pedersen, Walther Batsberg; Philipsen, E.

    1985-01-01

    Polyethylene glycol in urine samples has been investigated by high performance liquid chromatography. The molecular weights ranged from 634 to 1338. The urine samples were applied to the chromatographic system without any pre-treatment. For samples with a concentration of 0.2% polyethylene glycol...

  13. Bluish Discolouration of Urine Drainage Tube and Bag in a Female Patient with Spina Bifida, Paraplegia, and Suprapubic Cystostomy

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2007-01-01

    Full Text Available We present a female patient with spina bifida, paraplegia, suprapubic cystostomy, and chronic constipation, who became anxious when she noticed a bluish discolouration of her urine drainage system. Urine microbiology revealed growth of Providencia stuartii and Staphylococcus aureus. There were no systemic features of infection and, therefore, antibiotics were not prescribed for asymptomatic bacteriuria. This patient was advised to change the urine bag every day, and was prescribed senna to facilitate bowel evacuation. She was reassured that bluish discolouration of the urine drainage tube and bag was a transient, benign phenomenon and not indicative of any underlying pathology. Over the next 7 days, the bluish discolouration gradually faded away. Clinical characteristics of patients who are likely to develop this phenomenon and the underlying biochemical mechanism for bluish discolouration of the urine drainage system are discussed in brief.

  14. Variability in the interpretation of DMSA scintigraphy after urine infection

    International Nuclear Information System (INIS)

    Craig, J.; Howman-Giles, R.; Uren, R.; Irwig, L.; Bernard, E.; Knight, J.; Sureshkumar, P.; Roy, L.P.

    1997-01-01

    Full text: This study investigated the extent of and potential reasons for interpretation disagreement of 99m Tc-DMSA scans after urine infection in children. Methods: 441 scans were selected from children with first urine infection (UTI) from 1993-1995. 294 scans were performed at a median time of seven days after UTI and 147 in children free from infection over one year follow-up. Two nuclear medicine physicians independently reported according to whether renal abnormality was present or absent and used the four level grading system described by Goldraich: grade 1-no more than two cortical defects; grade 2 -more than 2 defects; grade 3-diffuse reduction in uptake with or without defects; grade 4 -shrunken kidney <10% function. Indices for variability used were the percentage of agreement and kappa statistic, expressed as a percentage. For the grading scale used, both measures were weighted with integers representing the number of categories from perfect agreement. Disagreement was analysed for children, kidneys and kidney zones. Results: There was agreement in 86 per cent (kappa 69%) for the normal-abnormal DMSA scan dichotomy, the weighted agreement was 94 per cent (kappa 82%) for the grading scale. Disagreement of DMSA scan interpretation ≥ two grades was present in three cases (0.7%). The same level of agreement was present for the patient, kidney and kidney zones comparisons. Agreement was not influenced by age or the timing of scintigraphy after urine infection. Conclusion: Two experienced physicians showed good agreement in the interpretation DMSA scintigraphy in children after urine infection and using the grading system of Goldraich

  15. Ultrafast scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Botkin, D.A. [California Univ., Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley Lab., CA (United States)

    1995-09-01

    I have developed an ultrafast scanning tunneling microscope (USTM) based on uniting stroboscopic methods of ultrafast optics and scanned probe microscopy to obtain nanometer spatial resolution and sub-picosecond temporal resolution. USTM increases the achievable time resolution of a STM by more than 6 orders of magnitude; this should enable exploration of mesoscopic and nanometer size systems on time scales corresponding to the period or decay of fundamental excitations. USTM consists of a photoconductive switch with subpicosecond response time in series with the tip of a STM. An optical pulse from a modelocked laser activates the switch to create a gate for the tunneling current, while a second laser pulse on the sample initiates a dynamic process which affects the tunneling current. By sending a large sequence of identical pulse pairs and measuring the average tunnel current as a function of the relative time delay between the pulses in each pair, one can map the time evolution of the surface process. USTM was used to measure the broadband response of the STM`s atomic size tunnel barrier in frequencies from tens to hundreds of GHz. The USTM signal amplitude decays linearly with the tunnel junction conductance, so the spatial resolution of the time-resolved signal is comparable to that of a conventional STM. Geometrical capacitance of the junction does not appear to play an important role in the measurement, but a capacitive effect intimately related to tunneling contributes to the measured signals and may limit the ultimate resolution of the USTM.

  16. Transmission acoustic microscopy investigation

    Science.gov (United States)

    Maev, Roman; Kolosov, Oleg; Levin, Vadim; Lobkis, Oleg

    The nature of acoustic contrast, i.e. the connection of the amplitude and phase of the output signal of the acoustic microscope with the local values of the acoustic parameters of the sample (density, elasticity, viscosity) is a central problem of acoustic microscopy. A considerable number of studies have been devoted to the formation of the output signal of the reflection scanning acoustic microscope. For the transmission acoustic microscope (TAM) this problem has remained almost unstudied. Experimental investigation of the confocal system of the TAM was carried out on an independently manufactured laboratory mockup of the TAM with the working frequency of the 420 MHz. Acoustic lenses with the radius of curvature of about 500 microns and aperture angle of 45 deg were polished out in the end faces of two cylindrical sound conductors made from Al2O3 single crystals with an axis parallel to the axis C of the crystal (the length of the sound conductor is 20 mm; diameter, 6 mm). At the end faces of the sound conductor, opposite to the lenses, CdS transducers with a diameter of 2 mm were disposed. The electric channel of the TAM provided a possibility for registering the amplitude of the microscope output signal in the case of the dynamic range of the 50 dB.

  17. Prognostic value of a quantitative analysis of lipoarabinomannan in urine from patients with HIV-associated tuberculosis.

    Directory of Open Access Journals (Sweden)

    Andrew D Kerkhoff

    Full Text Available Detection of the mycobacterial cell wall antigen lipoarabinomannan (LAM in urine can be used to diagnose HIV-associated tuberculosis (TB using a qualitative (positive/negative read-out. However, it is not known whether the quantity of LAM present in urine provides additional prognostic information.Consecutively recruited adult outpatients initiating antiretroviral therapy (ART in South Africa were investigated for TB regardless of clinical symptoms using sputum smear microscopy and liquid culture (reference standard. Urine samples were tested using the Clearview TB-ELISA for LAM and the Xpert MTB/RIF assay. The ELISA optical densities (OD were used as a quantitative assessment of urine LAM. Among 514 patients with complete sputum and urine LAM OD results, culture-confirmed TB was diagnosed in 84 patients. Twenty-three (27.3% were LAM-positive with a median LAM OD of 0.68 (IQR 0.16-2.43; range, 0.10-3.29 and 61 (72.6% were LAM negative (LAM OD <0.1 above background. Higher LAM ODs were associated with a range of prognostic indices, including lower CD4 cell counts, lower haemoglobin levels, higher blood neutrophil counts and higher mycobacterial load as assessed using both sputum and urine samples. The median LAM OD among patients who died was more than 6.8-fold higher than that of patients who remained alive at 3 months (P<0.001. The small number of deaths, however, precluded adequate assessment of mortality risk stratified according to urine LAM OD.In patients with HIV-associated TB, concentrations of LAM in urine were strongly associated with a range of poor prognostic characteristics known to be associated with mortality risk. Urine LAM assays with a semi-quantitative (negative vs. low-positive vs. high-positive read-out may have improved clinical utility over assays with a simple binary result.

  18. International Multidisciplinary Microscopy Congress

    CERN Document Server

    Oral, Ahmet; Ozer, Mehmet; InterM; INTERM2013

    2014-01-01

    The International Multidisciplinary Microscopy Congress (INTERM2013) was organized on October 10-13, 2013. The aim of the congress was to bring together scientists from various branches to discuss the latest advances in the field of microscopy. The contents of the congress have been broadened to a more "interdisciplinary" scope, so as to allow all scientists working on related subjects to participate and present their work. These proceedings include 39 peer-reviewed technical papers, submitted by leading academic and research institutions from over 12 countries and representing some of the most cutting-edge research available. The 39 papers are grouped into the following sections: - Applications of Microscopy in the Physical Sciences - Applications of Microscopy in the Biological Sciences

  19. Determination of the CD performance and carbon contamination of an EUV mask by using a coherent scattering microscopy/in-situ contamination system

    International Nuclear Information System (INIS)

    Doh, Jonggul; Jeong, Changyoung; Lee, Sangsul; Lee, Jaeuk; Cha, Hansun; Ahn, Jinho; Lee, Donggun; Kim, Seongsue; Cho, Hanku; Rah, Seungyu

    2010-01-01

    The impact of carbon contamination on imaging performance was analyzed using an in-situ accelerated contamination system (ICS) combined with coherent scattering microscopy (CSM) at the 11B extreme ultraviolet lithography (EUVL) beamline of the Pohang Accelerator Laboratory (PAL). The CSM/ICS is composed of the CSM for measuring imaging properties and the ICS for accelerating the carbon contamination. The CD (critical dimension) and the reflectivity of the mask were compared before and after carbon contamination through acceleration exposure. The reflectivity degradation was 1.3%, 2.1%, and 2.5% after 1-, 2-, and 3-hour exposures, respectively, due to carbon contamination of 5, 10, and 20 nm as measured by using a Zygo interferometer. The mask CD change of an 88-nm line and space pattern was analyzed using CSM and CD SEM (scanning electron microscope), and the result showed a similar trend, but a different absolute value. This difference confirmed the importance of the actinic inspection technique, which employs exactly the same imaging condition as the exposure tool.

  20. Reproductive system abnormalities in Schistosoma mansoni adult worms isolated from Nectomys squamipes (Muridae: Sigmodontinae: brightfield and confocal laser scanning microscopy analysis

    Directory of Open Access Journals (Sweden)

    Neves Renata Heisler

    2003-01-01

    Full Text Available Schistosoma mansoni adult worms with genital anomalies isolated from Nectomys squamipes (Muridae: Sigmodontinae were studied by confocal laser scanning microscopy under the reflected mode. One male without testicular lobes (testicular agenesia/anorchism and two females, one with an atrophied ovary and another with 17 uterine eggs, were identified. The absence of testicular lobes occurred in a worm presenting otherwise normal male adult characteristics: tegument, tubercles and a gynaecophoric canal with spines. In both female specimens the digestive tube showed a vacuolated appearance, and the specimen with supernumerary uterine eggs exhibited a developing miracidium and an egg with a formed shell. The area of the ventral sucker was similar in both specimens however the tegument thickness, ovary and vitelline glands of the specimen with the atrophied ovary were smaller than those of the one with supernumerary eggs. These reported anomalies in the reproductive system call attention to the need to improve our understanding of genetic regulation and the possible role of environmental influences upon trematode development.

  1. Human Urine-Derived Renal Progenitors for Personalized Modeling of Genetic Kidney Disorders.

    Science.gov (United States)

    Lazzeri, Elena; Ronconi, Elisa; Angelotti, Maria Lucia; Peired, Anna; Mazzinghi, Benedetta; Becherucci, Francesca; Conti, Sara; Sansavini, Giulia; Sisti, Alessandro; Ravaglia, Fiammetta; Lombardi, Duccio; Provenzano, Aldesia; Manonelles, Anna; Cruzado, Josep M; Giglio, Sabrina; Roperto, Rosa Maria; Materassi, Marco; Lasagni, Laura; Romagnani, Paola

    2015-08-01

    The critical role of genetic and epigenetic factors in the pathogenesis of kidney disorders is gradually becoming clear, and the need for disease models that recapitulate human kidney disorders in a personalized manner is paramount. In this study, we describe a method to select and amplify renal progenitor cultures from the urine of patients with kidney disorders. Urine-derived human renal progenitors exhibited phenotype and functional properties identical to those purified from kidney tissue, including the capacity to differentiate into tubular cells and podocytes, as demonstrated by confocal microscopy, Western blot analysis of podocyte-specific proteins, and scanning electron microscopy. Lineage tracing studies performed with conditional transgenic mice, in which podocytes are irreversibly tagged upon tamoxifen treatment (NPHS2.iCreER;mT/mG), that were subjected to doxorubicin nephropathy demonstrated that renal progenitors are the only urinary cell population that can be amplified in long-term culture. To validate the use of these cells for personalized modeling of kidney disorders, renal progenitors were obtained from (1) the urine of children with nephrotic syndrome and carrying potentially pathogenic mutations in genes encoding for podocyte proteins and (2) the urine of children without genetic alterations, as validated by next-generation sequencing. Renal progenitors obtained from patients carrying pathogenic mutations generated podocytes that exhibited an abnormal cytoskeleton structure and functional abnormalities compared with those obtained from patients with proteinuria but without genetic mutations. The results of this study demonstrate that urine-derived patient-specific renal progenitor cultures may be an innovative research tool for modeling of genetic kidney disorders. Copyright © 2015 by the American Society of Nephrology.

  2. Comparison of efficiency of the retreatment procedure between Wave One Gold and Wave One systems by Micro-CT and confocal microscopy: an in vitro study.

    Science.gov (United States)

    Canali, Lyz Cristina Furquim; Duque, Jussaro Alves; Vivan, Rodrigo Ricci; Bramante, Clovis Monteiro; Só, Marcus Vinícius Reis; Duarte, Marco Antonio Hungaro

    2018-04-19

    To compare, by Micro-CT and confocal laser scanning microscopy (CLSM), the ability of the Wave One Gold and Wave One systems to remove filling material from mesial canals of mandibular molars, effective time spent; quantity of extruded material, and percentage of sealer in the dentinal tubules after retreatment and re-obturation procedures. Ten first mandibular molars (n = 20 mesial canals) were prepared and filled with gutta-percha and Endofill sealer mixed with Rhodamine B dye using the single cone technique. After 7 days, the canals were scanned using a high-definition micro-computer tomography with 19-mm voxel size and divided into two groups (n = 10) according to the system used in retreatment: group 1, Wave One (WO), and group 2, Wave One Gold (WG). After removing filling material with the primary file of each system, the WO 40/.08 and WG 35/.06 files were used. After using each file, a new scanning was performed and the residual filling material and extruded filling material were measured. The effective time spent to remove the canal filling was measured after each instrument. After retreatment, the teeth were re-obturated with gutta-percha and AH Plus sealer mixed with fluorescein dye using the single-cone technique. The roots were sectioned at 2, 4 and 6 mm and analysed by CLSM to measure the percentage of remaining sealer and the sealer of the new root canal filling. The data were statistically compared (P  0.05). When using WO 25, the operator spent significantly less effective time than when using WG 25 (P  0.05). Neither of the two systems removed all the filling material. The WG system presented similar ability in removing filling and extruded material in comparison with WO system. The effective time spent was shorter for WO 25 than for WG 25. Wave One Gold can be an alternative to perform retreatment considering that in comparison with Wave One, there was no difference in filling material removal capacity and extruded materials

  3. Recreational drug use at a major music festival: trend analysis of anonymised pooled urine

    DEFF Research Database (Denmark)

    Hoegberg, Lotte Christine Groth; Christiansen, Cecilie; Soe, Jesper

    2018-01-01

    of recreational drugs used and NPS available in Denmark is limited as identification is possible only when consumers become patients in the healthcare system or through drug seizures. We aimed to detect classical recreational drugs and NPS in the urine of music festival attendees and evaluate if the use of NPS...... could have been predicted by comparing study data with drug seizure data from the previous year published by European and Danish health authorities.Methods: In a cross-sectional study, 44 urine samples were collected from three urinals at Roskilde Festival 2016—the largest Danish music festival. Two...... spectrometry (UPLC-HR-TOF-MS). Data were processed using an in-house library of 467 target substances, including legal and illegal drugs and metabolites. Urine drug-screening immunoassays were also evaluated and results were compared to UPLC-HR-TOF-MS results. Results: In total, 77 drugs, including metabolites...

  4. Investigating consumer attitudes towards the new technology of urine separation.

    Science.gov (United States)

    Pahl-Wostl, C; Schönborn, A; Willi, N; Muncke, J; Larsen, T A

    2003-01-01

    The technology of urine separation and the recycling of anthropogenic nutrients as fertilizer in agriculture are considered as major innovations to improve the sustainability of today's urban wastewater management. The acceptance of consumers will be key for the introduction of the new technology. Citizens will have to make important decisions in their role as tenants and owners of houses and as consumers buying products fertilized with urine. Consumer attitudes towards the new technology were explored in a number of citizen focus groups in Switzerland. Focus groups are deliberate, moderated group discussions with informed citizens on a certain topic. The information was provided by a computer based information system specifically designed for this purpose. The acceptance of individual citizens for the new technology proved to be quite high. The majority of the citizens expressed their willingness to move into an apartment with NoMix toilets and to buy food fertilized with urine. However, they were not willing to accept additional financial costs or efforts. Arguments related to long-term sustainability (closing nutrient cycles) were of less importance than arguments that relate directly to the effects of micropollutants on human and ecosystem health. For the introduction of the new technology on a wide scale it will thus be crucial to explore the fate and effects of micropollutants.

  5. Peptidomics of urine and other biofluids for cancer diagnostics.

    Science.gov (United States)

    Bauça, Josep Miquel; Martínez-Morillo, Eduardo; Diamandis, Eleftherios P

    2014-08-01

    Cancer is a leading cause of death worldwide. The low diagnostic sensitivity and specificity of most current cancer biomarkers make early cancer diagnosis a challenging task. The comprehensive study of peptides and small proteins in a living system, known as "peptidomics," represents an alternative technological approach to the discovery of potential biomarkers for the assessment of a wide variety of pathologies. This review examines the current status of peptidomics for several body fluids, with a focus on urine, for cancer diagnostics applications. Several studies have used high-throughput technologies to characterize the peptide content of different body fluids. Because of its noninvasive collection and high stability, urine is a valuable source of candidate cancer biomarkers. A wide variety of preanalytical issues concerning patient selection and sample handling need to be considered, because not doing so can affect the quality of the results by introducing bias and artifacts. Optimization of both the analytical strategies and the processing of bioinformatics data is also essential to minimize the false-discovery rate. Peptidomics-based studies of urine and other body fluids have yielded a number of biomolecules and peptide panels with potential for diagnosing different types of cancer, especially of the ovary, prostate, and bladder. Large-scale studies are needed to validate these molecules as cancer biomarkers. © 2013 American Association for Clinical Chemistry.

  6. [A study of biomechanical method for urine test based on color difference estimation].

    Science.gov (United States)

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun

    2008-02-01

    The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.

  7. Determination of uranium isotopes in urine

    International Nuclear Information System (INIS)

    Lellis, I.R.; Silva, D.V.F.M. Rey; Taddei, M.H.T.

    2017-01-01

    Variable concentrations of uranium occur naturally in waters, plant products and soils. Small amounts of this element are routinely incorporated by man. Occupationally exposed individuals (IOEs) are subject to the incorporation of higher amounts of uranium into their work routines. The effects on human health resulting from the incorporation of uranium in environmental doses are not very well established and are currently recognized as of little relevance. The incorporation resulting from occupational activities, where higher doses can be found, represents a health risk resulting from chemical damages to the kidneys. Considering that uranium is eliminated from the human body through urine and feces, and that the concentration in the urine can be obtained by means of radiochemical analyzes, this can be considered an efficient indirect method to verify the incorporation of this element. In the work the isotopes of 234 U, 235 U and 238 U were analyzed in urine samples of IOEs and the rate of uranium present in them was verified

  8. Measurement of menadione in urine by HPLC.

    Science.gov (United States)

    Al Rajabi, Ala; Peterson, James; Choi, Sang-Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-09-15

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C(30) column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H(2)O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R(2)) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  9. Urine alkalization facilitates uric acid excretion

    Science.gov (United States)

    2010-01-01

    Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet) and others composed of less protein but vegetable-fruit rich food materials (alkali diet). Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+) and anions (Cl-,SO42-,PO4-) necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai) were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-]), indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body. PMID:20955624

  10. Urine alkalization facilitates uric acid excretion

    Directory of Open Access Journals (Sweden)

    Seyama Issei

    2010-10-01

    Full Text Available Abstract Background Increase in the incidence of hyperuricemia associated with gout as well as hypertension, renal diseases and cardiovascular diseases has been a public health concern. We examined the possibility of facilitated excretion of uric acid by change in urine pH by managing food materials. Methods Within the framework of the Japanese government's health promotion program, we made recipes which consist of protein-rich and less vegetable-fruit food materials for H+-load (acid diet and others composed of less protein but vegetable-fruit rich food materials (alkali diet. Healthy female students were enrolled in this consecutive 5-day study for each test. From whole-day collected urine, total volume, pH, organic acid, creatinine, uric acid and all cations (Na+,K+,Ca2+,Mg2+,NH4+ and anions (Cl-,SO42-,PO4- necessary for the estimation of acid-base balance were measured. Results Urine pH reached a steady state 3 days after switching from ordinary daily diets to specified regimens. The amount of acid generated ([SO42-] +organic acid-gut alkai were linearly related with those of the excretion of acid (titratable acidity+ [NH4+] - [HCO3-], indicating that H+ in urine is generated by the metabolic degradation of food materials. Uric acid and excreted urine pH retained a linear relationship, where uric acid excretion increased from 302 mg/day at pH 5.9 to 413 mg/day at pH 6.5, despite the fact that the alkali diet contained a smaller purine load than the acid diet. Conclusion We conclude that alkalization of urine by eating nutritionally well-designed food is effective for removing uric acid from the body.

  11. Sequential analysis of selected actinides in urine

    International Nuclear Information System (INIS)

    Kramer, G.H.

    1980-07-01

    The monitoring of personnel by urinalysis for suspected contamination by actinides necessitated the development and implementation of an analytical scheme that will separate and identify alpha emitting radionuclides of these elements. The present work deals with Pu, Am, and Th. These elements are separated from an ashed urine sample by means of coprecipitation and ion exchange techniques. The final analysis is carried out by electroplating the actinides and counting in a α-spectrometer. Mean recoveries of these elements from urine are: Pu 64%, Am 74% and Th 69%. (auth)

  12. Diagnostic performance of Schistosoma real-time PCR in urine samples from Kenyan children infected with Schistosoma haematobium

    DEFF Research Database (Denmark)

    Vinkeles Melchers, Natalie V. S.; van Dam, Govert J.; Shaproski, David

    2014-01-01

    treatment. METHODOLOGY: Previously collected urine samples (N = 390) from 114 preselected proven parasitological and/or clinical S. haematobium positive Kenyan schoolchildren were analyzed by a Schistosoma internal transcribed spacer-based real-time PCR after 14 years of storage. Pre-treatment day......, respectively. Based on the 'gold standard', PCR showed high sensitivity (>92%) as compared to >31% sensitivity for microscopy, both pre- and post-treatment. CONCLUSIONS/SIGNIFICANCE: Detection and quantification of Schistosoma DNA in urine by real-time PCR was shown to be a powerful and specific diagnostic...

  13. Development of a user-friendly system for image processing of electron microscopy by integrating a web browser and PIONE with Eos.

    Science.gov (United States)

    Tsukamoto, Takafumi; Yasunaga, Takuo

    2014-11-01

    Eos (Extensible object-oriented system) is one of the powerful applications for image processing of electron micrographs. In usual cases, Eos works with only character user interfaces (CUI) under the operating systems (OS) such as OS-X or Linux, not user-friendly. Thus, users of Eos need to be expert at image processing of electron micrographs, and have a little knowledge of computer science, as well. However, all the persons who require Eos does not an expert for CUI. Thus we extended Eos to a web system independent of OS with graphical user interfaces (GUI) by integrating web browser.Advantage to use web browser is not only to extend Eos with GUI, but also extend Eos to work under distributed computational environment. Using Ajax (Asynchronous JavaScript and XML) technology, we implemented more comfortable user-interface on web browser. Eos has more than 400 commands related to image processing for electron microscopy, and the usage of each command is different from each other. Since the beginning of development, Eos has managed their user-interface by using the interface definition file of "OptionControlFile" written in CSV (Comma-Separated Value) format, i.e., Each command has "OptionControlFile", which notes information for interface and its usage generation. Developed GUI system called "Zephyr" (Zone for Easy Processing of HYpermedia Resources) also accessed "OptionControlFIle" and produced a web user-interface automatically, because its mechanism is mature and convenient,The basic actions of client side system was implemented properly and can supply auto-generation of web-form, which has functions of execution, image preview, file-uploading to a web server. Thus the system can execute Eos commands with unique options for each commands, and process image analysis. There remain problems of image file format for visualization and workspace for analysis: The image file format information is useful to check whether the input/output file is correct and we also

  14. Confocal Raman Microscopy

    CERN Document Server

    Dieing, Thomas; Toporski, Jan

    2011-01-01

    Confocal Raman Microscopy is a relatively new technique that allows chemical imaging without specific sample preparation. By integrating a sensitive Raman spectrometer within a state-of-the-art microscope, Raman microscopy with a spatial resolution down to 200nm laterally and 500nm vertically can be achieved using visible light excitation. Recent developments in detector and computer technology as well as optimized instrument design have reduced integration times of Raman spectra by orders of magnitude, so that complete images consisting of tens of thousands of Raman spectra can be acquired in seconds or minutes rather than hours, which used to be standard just one decade ago. The purpose of this book is to provide the reader a comprehensive overview of the rapidly developing field of Confocal Raman Microscopy and its applications.

  15. Atomic Force Microscopy Study of Protein–Protein Interactions in the Cytochrome CYP11A1 (P450scc-Containing Steroid Hydroxylase System

    Directory of Open Access Journals (Sweden)

    Zöllner A

    2011-01-01

    Full Text Available Abstract Atomic force microscopy (AFM and photon correlation spectroscopy (PCS were used for monitoring of the procedure for cytochrome CYP11A1 monomerization in solution without phospholipids. It was shown that the incubation of 100 μM CYP11A1 with 12% Emulgen 913 in 50 mM KP, pH 7.4, for 10 min at T = 22°C leads to dissociation of hemoprotein aggregates to monomers with the monomerization degree of (82 ± 4%. Following the monomerization procedure, CYP11A1 remained functionally active. AFM was employed to detect and visualize the isolated proteins as well as complexes formed between the components of the cytochrome CYP11A1-dependent steroid hydroxylase system. Both Ad and AdR were present in solution as monomers. The typical heights of the monomeric AdR, Ad and CYP11A1 images were measured by AFM and were found to correspond to the sizes 1.6 ± 0.2 nm, 1.0 ± 0.2 nm and 1.8 ± 0.2 nm, respectively. The binary Ad/AdR and AdR/CYP11A1mon complexes with the heights 2.2 ± 0.2 nm and 2.8 ± 0.2 nm, respectively, were registered by use of AFM. The Ad/CYP11A1mon complex formation reaction was kinetically characterized based on optical biosensor data. In addition, the ternary AdR/Ad/CYP11A1 complexes with a typical height of 4 ± 1 nm were AFM registered.

  16. Confocal scanning microscopy

    DEFF Research Database (Denmark)

    Bariani, Paolo

    This report is based on a metrological investigation on confocal microscopy technique carried out by Uffe Rolf Arlø Theilade and Paolo Bariani. The purpose of the experimental activity was twofold a metrological instrument characterization and application to assessment of rough PP injection moulded...... replicated topography. Confocal microscopy is seen to be a promising technique in metrology of microstructures. Some limitations with respect to surface metrology were found during the experiments. The experiments were carried out using a Zeiss LSM 5 Pascal microscope owned by the Danish Polymer Centre...

  17. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  18. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    Science.gov (United States)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  19. Property changes of urinary nanocrystallites and urine of uric acid stone formers after taking potassium citrate

    International Nuclear Information System (INIS)

    Zhang, Guang-Na; Ouyang, Jian-Ming; Xue, Jun-Fa; Shang, Yun-Feng

    2013-01-01

    The property changes of urinary nanocrystallites in 20 cases of uric acid (UA) stone formers after 1 week of potassium citrate (K 3 cit) intake were comparatively studied by X-ray diffraction analysis, Fourier transform infrared spectroscopy, nanoparticle size analysis, and transmission electron microscopy. Before K 3 cit intake, the urinary crystallites mainly contained UA and calcium oxalate. After K 3 cit intake, the components changed to urate and UA; the qualities, species, and amounts of aggregated crystallites decreased; urine pH, citrate, and glycosaminoglycan excretions increased; and UA excretion, Zeta potential, and crystallite size decreased. The stability of crystallites followed the order: controls > patients after taking K 3 cit > patients before taking K 3 cit. Therefore, the components of urinary stones were closely related to the components of urinary crystallites. - Graphical abstract: The relationships among stone components, urinary crystallite components, and urine pH were established. The crystallites stability order was: controls > patients after taking K 3 cit > patients before taking K 3 cit. Highlights: • Urine crystallite property of uric acid stone former after K 3 cit intake was studied. • The components of crystallites in urine are closely related to type of stones. • After K 3 cit intake the qualities and species of crystallites decreased. • After K 3 cit intake the amount of aggregated crystallites decreased. • The stability of urinary crystallites of UA patients increased after taking K 3 cit

  20. Solar thermal evaporation of human urine for nitrogen and phosphorus recovery in Vietnam

    International Nuclear Information System (INIS)

    Antonini, Samantha; Nguyen, Phong Thanh; Arnold, Ute; Eichert, Thomas; Clemens, Joachim

    2012-01-01

    A No Mix sanitation system was installed in a dormitory at the University of Can Tho in Vietnam, with the objective of recycling nutrients from source separated urine. This paper presents a pilot scale evaporation technology, and investigates the feasibility of recovering nitrogen and phosphorus from human urine by solar still for use as fertilizer. After 26 days of sun exposure, 360 g of solid fertilizer material was recovered from 50 L undiluted urine. This urine-derived fertilizer was mainly composed of sodium chloride, and had phosphorus and nitrogen contents of almost 2%. When tested with maize and ryegrass, the urine fertilizer led to biomass yields and phosphorus and nitrogen uptakes comparable to those induced by a commercial mineral fertilizer. Urine acidification with sulfuric or phosphoric acid prior treatment reduced nitrogen losses, improved the nutrient content of the generated fertilizers, and induced higher biomass yields and nitrogen and phosphorus uptakes than the commercial mineral fertilizer. However, acidification is not recommended in developing countries due to additional costs and handling risks. The fate of micropollutants and the possibility of separating sodium chloride from other beneficial nutrients require further investigation. - Highlights: ► 360 g of fertilizer was derived from 50 L urine by solar evaporative distillation. ► The fertilizer contained 90% sodium chloride, 3% sulfur, 2% nitrogen, 2% phosphorus. ► It induced biomass yields comparable to those produced by a commercial fertilizer. ► Urine acidification improved the nutrient content of the generated fertilizers. ► Acidification is not recommended for use in developing countries (costs, safety).

  1. New Markers: Urine Xanthine Oxidase and Myeloperoxidase in the Early Detection of Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    Pınar Ciragil

    2014-01-01

    Full Text Available Objectives. The aim of this study was to evaluate if xanthine oxidase and myeloperoxidase levels quantitation method may alternate routine culture method, which takes more time in the diagnosis of urinary tract infections. Material and Methods. Five hundred and forty-nine outpatients who had admitted to Clinic Microbiology Laboratory were included in the study. The microorganisms were identified by using VITEK System. The urine specimens that were negative from the quantitative urine culture were used as controls. The activities of MPO and XO in spot urine were measured by spectrophotometric method. Results. Through the urine cultures, 167 bacteria were isolated from 163 urine specimens; 386 cultures yielded no bacterial growth. E. coli was the most frequent pathogen. In infection with E. coli both XO and MPO levels were increased the most. The sensitivity, specificity, positive predictive value, and negative predictive value for XO were 100%, 100%, 100%, and 100%, respectively. These values for MPO were 87%, 100%, 100%, and 94%, respectively. Conclusion. These data obtained suggest that urine XO and MPO levels may be new markers in the early detection of UTI.

  2. Magnetic graphene oxide as adsorbent for the determination of polycyclic aromatic hydrocarbon metabolites in human urine.

    Science.gov (United States)

    Zhu, Linli; Xu, Hui

    2014-09-01

    Detection of monohydroxy polycyclic aromatic hydrocarbons metabolites in urine is an advisable and valid method to assess human environmental exposure to polycyclic aromatic hydrocarbons. In this work, novel Fe3O4/graphene oxide composites were prepared and their application in the magnetic solid-phase extraction of monohydroxy polycyclic aromatic hydrocarbons in urine was investigated by coupling with liquid chromatography and mass spectrometry. In the hybrid material, superparamagnetic Fe3O4 nanoparticles provide fast separation to simplify the analytical process and graphene oxide provides a large functional surface for the adsorption. The prepared magnetic nanocomposites were characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy, and vibrating sample magnetometry. The experimental conditions were optimized systematically. Under the optimal conditions, the recoveries of these compounds were in the range of 98.3-125.2%, the relative standard deviations ranged between 6.8 and 15.5%, and the limits of detection were in the range of 0.01-0.15 ng/mL. The simple, quick, and affordable method was successfully used in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities. The results indicated that the monohydroxy polycyclic aromatic hydrocarbons level in human urine can provide useful information for environmental exposure to polycyclic aromatic hydrocarbons. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Radioimmunoassay of bleomycin in plasma and urine

    International Nuclear Information System (INIS)

    Teale, J.D.; Clough, J.M.; Marks, V.

    1977-01-01

    Antibodies to bleomycin were raised by immunization of sheep and rabbits with bleomycin-albumin conjugates. The combination of a high-titre, high-avidity sheep antiserum and iodinated bleomycin produced a radioimmunoassay sensitive to 8 ng of bleomycin per ml of plasma or urine. Untreated specimens (100 μl) of plasma or urine could be added directly to the assay tubes. The anti-serum was specific for bleomycin and showed no cross-reaction with other anti-cancer agents used in combination chemotherapy. Over a concentration range of 20 to 100 ng/ml. recovery of bleomycin from plasma was 110% and from urine, 93%. Repeated assay of plasma samples showed a decrease in bleomycin levels unless the samples were kept at 4 0 C or below. Assay of bleomycin levels in plasma and urine from patients under treatment with bleomycin showed similarities with results reported using a microbiological assay. The radioimmunoassay offers a more reliable, rapid and sensitive method for the measurement of bleomycin. (author)

  4. Potentiometric determination of iodides in urine

    International Nuclear Information System (INIS)

    Gikolaev, B.A.; Primakova, L.N.; Rakhman'ko, E.M.

    1996-01-01

    Variants of potentiometric method: determination using a calibrations plot, the Gran method, and the double addition method are considered. The method of double additions of the test solution to the reference one is suggested as the most favorable method of determining iodides in urine under clinical laboratory conditions. Refs. 5, tabs. 2

  5. Getting a Urine Test (For Kids)

    Medline Plus

    Full Text Available ... Answers (Q&A) Staying Safe Videos for Educators Search English Español Getting a Urine Test (Video) KidsHealth / ... Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for educational purposes only. For ...

  6. Urine ethanol concentration and alcohol hangover severity

    NARCIS (Netherlands)

    Brookhuis, Karel; Van De Loo, Aurora; Mackus, M.; Verster, Joris

    Background The aim of this study was to examine the relationship between urine ethanol concentration and alcohol hangover severity. Methods N = 36 healthy social drinkers participated in a naturalistic study, comprising a hangover day and a control day. N = 18 of them have regular hangovers (the

  7. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject`s body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  8. Urine sample collection protocols for bioassay samples

    Energy Technology Data Exchange (ETDEWEB)

    MacLellan, J.A.; McFadden, K.M.

    1992-11-01

    In vitro radiobioassay analyses are used to measure the amount of radioactive material excreted by personnel exposed to the potential intake of radioactive material. The analytical results are then used with various metabolic models to estimate the amount of radioactive material in the subject's body and the original intake of radioactive material. Proper application of these metabolic models requires knowledge of the excretion period. It is normal practice to design the bioassay program based on a 24-hour excretion sample. The Hanford bioassay program simulates a total 24-hour urine excretion sample with urine collection periods lasting from one-half hour before retiring to one-half hour after rising on two consecutive days. Urine passed during the specified periods is collected in three 1-L bottles. Because the daily excretion volume given in Publication 23 of the International Commission on Radiological Protection (ICRP 1975, p. 354) for Reference Man is 1.4 L, it was proposed to use only two 1-L bottles as a cost-saving measure. This raised the broader question of what should be the design capacity of a 24-hour urine sample kit.

  9. Determination of natural thorium in urines

    International Nuclear Information System (INIS)

    Jeanmaire, L.; Jammet, H.

    1959-01-01

    A procedure for the quantitative analysis of thorium in urine is described. After precipitation with ammonium hydroxide, dissolution of the precipitate, extraction at pH 4-4.2 with cupferron in chloroformic solution and mineralization, a colorimetric determination of thorium with thorin is performed. It is thus possible to detect about 2 γ of thorium in the sample. (author) [fr

  10. URINE CULTURE CONTAMINATION: A ONE-YEAR ...

    African Journals Online (AJOL)

    boaz

    Background: Urine culture contamination is a significant cause of delay in treatment of patients being investigated for urinary tract infection. ... Lowest contamination rates were in Emergency Paediatric Unit (EPU) and intensive ... The female gender was found to be the most significant predictor of higher contamination rate.

  11. High-resolution intravital microscopy.

    Directory of Open Access Journals (Sweden)

    Volker Andresen

    Full Text Available Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy--the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and

  12. High-Resolution Intravital Microscopy

    Science.gov (United States)

    Andresen, Volker; Pollok, Karolin; Rinnenthal, Jan-Leo; Oehme, Laura; Günther, Robert; Spiecker, Heinrich; Radbruch, Helena; Gerhard, Jenny; Sporbert, Anje; Cseresnyes, Zoltan; Hauser, Anja E.; Niesner, Raluca

    2012-01-01

    Cellular communication constitutes a fundamental mechanism of life, for instance by permitting transfer of information through synapses in the nervous system and by leading to activation of cells during the course of immune responses. Monitoring cell-cell interactions within living adult organisms is crucial in order to draw conclusions on their behavior with respect to the fate of cells, tissues and organs. Until now, there is no technology available that enables dynamic imaging deep within the tissue of living adult organisms at sub-cellular resolution, i.e. detection at the level of few protein molecules. Here we present a novel approach called multi-beam striped-illumination which applies for the first time the principle and advantages of structured-illumination, spatial modulation of the excitation pattern, to laser-scanning-microscopy. We use this approach in two-photon-microscopy - the most adequate optical deep-tissue imaging-technique. As compared to standard two-photon-microscopy, it achieves significant contrast enhancement and up to 3-fold improved axial resolution (optical sectioning) while photobleaching, photodamage and acquisition speed are similar. Its imaging depth is comparable to multifocal two-photon-microscopy and only slightly less than in standard single-beam two-photon-microscopy. Precisely, our studies within mouse lymph nodes demonstrated 216% improved axial and 23% improved lateral resolutions at a depth of 80 µm below the surface. Thus, we are for the first time able to visualize the dynamic interactions between B cells and immune complex deposits on follicular dendritic cells within germinal centers (GCs) of live mice. These interactions play a decisive role in the process of clonal selection, leading to affinity maturation of the humoral immune response. This novel high-resolution intravital microscopy method has a huge potential for numerous applications in neurosciences, immunology, cancer research and developmental biology

  13. Stability of Synthetic Cathinones in Urine.

    Science.gov (United States)

    Glicksberg, Lindsay; Kerrigan, Sarah

    2018-03-01

    In this report, we evaluate the concentration, pH, temperature and analyte-dependent effects on cathinone stability in preserved human urine. A total of 22 synthetic cathinones were evaluated at 100 ng/mL and 1,000 ng/mL in pH 4 and pH 8 urine over 6 months. Specimens were stored at -20°C, 4°C, 20°C and 32°C. The stability of synthetic cathinones was highly dependent on urine pH and storage temperature. Cathinones were considerably more stable in acidic urine (pH 4) at low temperature. In alkaline urine (pH 8) at 32°C, significant losses (>20%) were observed within hours for the majority of drugs. In contrast, all drugs were stable in frozen and refrigerated urine at pH 4 for the duration of the study. These results highlight the importance of sample storage and the potential for pre-analytical changes in concentration during routine shipping and handling of specimens. Significant structural influence was also observed. Cathinones bearing a tertiary amine (pyrrolidine group) were significantly more stable than their secondary amine counterparts. The methylenedioxy group also exerted a significant stabilizing effect on both the tertiary and secondary amines. In the absence of the methylenedioxy group, no significant differences in stability were observed between the unsubstituted and ring substituted secondary amines. Half-lives at ambient temperature in pH 8 urine ranged from 9 h (3-fluoromethcathinone) to 4.3 months (methylenedioxypyrovalerone and 3,4-methylenedioxy-α-pyrrolidinobutiophenone), demonstrating the importance of analyte dependence, and the dual stabilizing effect of both the pyrollidine and methylenedioxy groups. Biological evidence may be subjected to a variety of environmental conditions prior to, and during transport to the forensic laboratory. These findings demonstrate the inherent instability of certain cathinone species in biological evidence under some conditions. Moreover, this study highlights the need for quantitative drug findings in

  14. Fluorescence confocal polarizing microscopy

    Indian Academy of Sciences (India)

    Much of the modern understanding of orientational order in liquid crystals (LCs) is based on polarizing microscopy (PM). A PM image bears only two-dimensional (2D) information, integrating the 3D pattern of optical birefringence over the path of light. Recently, we proposed a technique to image 3D director patterns by ...

  15. Ballistic hole magnetic microscopy

    NARCIS (Netherlands)

    Haq, E.; Banerjee, T.; Siekman, M.H.; Lodder, J.C.; Jansen, R.

    2005-01-01

    A technique to study nanoscale spin transport of holes is presented: ballistic hole magnetic microscopy. The tip of a scanning tunneling microscope is used to inject hot electrons into a ferromagnetic heterostructure, where inelastic decay creates a distribution of electron-hole pairs.

  16. Integrated forward osmosis-membrane distillation process for human urine treatment.

    Science.gov (United States)

    Liu, Qianliang; Liu, Caihong; Zhao, Lei; Ma, Weichao; Liu, Huiling; Ma, Jun

    2016-03-15

    This study demonstrated a forward osmosis-membrane distillation (FO-MD) hybrid system for real human urine treatment. A series of NaCl solutions at different concentrations were adopted for draw solutions in FO process, which were also the feed solutions of MD process. To establish a stable and continuous integrated FO-MD system, individual FO process with different NaCl concentrations and individual direct contact membrane distillation (DCMD) process with different feed temperatures were firstly investigated separately. Four stable equilibrium conditions were obtained from matching the water transfer rates of individual FO and MD processes. It was found that the integrated system is stable and sustainable when the water transfer rate of FO subsystem is equal to that of MD subsystem. The rejections to main contaminants in human urine were also investigated. Although individual FO process had relatively high rejection to Total Organic Carbon (TOC), Total Nitrogen (TN) and Ammonium Nitrogen (NH4(+)-N) in human urine, these contaminants could also accumulate in draw solution after long term performance. The MD process provided an effective rejection to contaminants in draw solution after FO process and the integrated system revealed nearly complete rejection to TOC, TN and NH4(+)-N. This work provided a potential treatment process for human urine in some fields such as water regeneration in space station and water or nutrient recovery from source-separated urine. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Advanced Microscopy of Microbial Cells

    DEFF Research Database (Denmark)

    Haagensen, Janus Anders Juul; Regenberg, Birgitte; Sternberg, Claus

    2011-01-01

    microscopy, super-resolution optical microscopy (STED, SIM, PALM) as well as atomic force microscopy and Raman spectroscopy. Using examples of bistability in microbial populations as well as biofilm development and differentiation in bacterial and yeast consortia, we demonstrate the importance of microscopy...

  18. Protein-Based Urine Test Predicts Kidney Transplant Outcomes

    Science.gov (United States)

    ... News Releases News Release Thursday, August 22, 2013 Protein-based urine test predicts kidney transplant outcomes NIH- ... supporting development of noninvasive tests. Levels of a protein in the urine of kidney transplant recipients can ...

  19. Epithelial Cells in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/epithelialcellsinurine.html Epithelial Cells in Urine To use the sharing features on ... page, please enable JavaScript. What is an Epithelial Cells in Urine Test? Epithelial cells are a type ...

  20. HPLC determination of betamethasone and prednisolone in urine samples using monolithic column

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.

    2011-01-01

    A fast and reliable HPLC method is reported for the separation and quantification of betamethasone and prednisolone in urine samples using Chromolith at the rate of Performance RP-l8e (100 mm x 4.6 mm) column. The separation and detection was achieved using an isocratic mobile phase composed of methanol:water (44:56 v/v) at 2.0 mL/min and wavelength of 254 nm. After successful optimisation of method parameters, it was applied to the urine samples. Solid phase extraction technique was used to clean the sample before analysis. The developed method was validated for the system suitability, precision and accuracy. The limits of defection for the prednisolone and betamethasone are 0.11 ng and 0.075 ng/10 macro L injection, respectively allowing their determination in human urine samples. Recovery for spiked urine samples was in the range of 97-103 %. The method offers a valuable alternative to the methodologies currently employed for separation and quantification of prednisolone and betamethasone in urine samples. A fast and reliable HPLC method is reported for the separation and quantification of betamethasone and prednisolone in urine samples using Chromolith at the rate of Performance RP-l8e (100 mm x 4.6 mm) column. The separation and detection was achieved using an isocratic mobile phase composed of methanol:water (44:56 v/v) at 2.0 mL/min and wavelength of 254 nm. After successful optimisation of method parameters, it was applied to the urine samples. Solid phase extraction technique was used to clean the sample before analysis. The developed method was validated for the system suitability, precision and accuracy. The limits of defection for the prednisolone and betamethasone are 0.11 ng and 0.075 ng/10 macro L injection, respectively allowing their determination in human urine samples. Recovery for spiked urine samples was in the range of 97-103 %. The method offers a valuable alternative to the methodologies currently employed for separation and quantification

  1. Polarized Light Microscopy

    Science.gov (United States)

    Frandsen, Athela F.

    2016-01-01

    Polarized light microscopy (PLM) is a technique which employs the use of polarizing filters to obtain substantial optical property information about the material which is being observed. This information can be combined with other microscopy techniques to confirm or elucidate the identity of an unknown material, determine whether a particular contaminant is present (as with asbestos analysis), or to provide important information that can be used to refine a manufacturing or chemical process. PLM was the major microscopy technique in use for identification of materials for nearly a century since its introduction in 1834 by William Fox Talbot, as other techniques such as SEM (Scanning Electron Microscopy), FTIR (Fourier Transform Infrared spectroscopy), XPD (X-ray Powder Diffraction), and TEM (Transmission Electron Microscopy) had not yet been developed. Today, it is still the only technique approved by the Environmental Protection Agency (EPA) for asbestos analysis, and is often the technique first applied for identification of unknown materials. PLM uses different configurations in order to determine different material properties. With each configuration additional clues can be gathered, leading to a conclusion of material identity. With no polarizing filter, the microscope can be used just as a stereo optical microscope, and view qualities such as morphology, size, and number of phases. With a single polarizing filter (single polars), additional properties can be established, such as pleochroism, individual refractive indices, and dispersion staining. With two polarizing filters (crossed polars), even more can be deduced: isotropy vs. anisotropy, extinction angle, birefringence/degree of birefringence, sign of elongation, and anomalous polarization colors, among others. With the use of PLM many of these properties can be determined in a matter of seconds, even for those who are not highly trained. McCrone, a leader in the field of polarized light microscopy, often

  2. Single spin stochastic optical reconstruction microscopy

    OpenAIRE

    Pfender, Matthias; Aslam, Nabeel; Waldherr, Gerald; Wrachtrup, Jörg

    2014-01-01

    We experimentally demonstrate precision addressing of single quantum emitters by combined optical microscopy and spin resonance techniques. To this end we utilize nitrogen-vacancy (NV) color centers in diamond confined within a few ten nanometers as individually resolvable quantum systems. By developing a stochastic optical reconstruction microscopy (STORM) technique for NV centers we are able to simultaneously perform sub diffraction-limit imaging and optically detected spin resonance (ODMR)...

  3. Integrated Photoacoustic and Fluorescence Confocal Microscopy

    OpenAIRE

    Wang, Yu; Maslov, Konstantin; Kim, Chulhong; Hu, Song; Wang, Lihong V.

    2010-01-01

    We have developed a dual-modality imaging system by integrating optical-resolution photoacoustic microscopy and fluorescence confocal microscopy to provide optical absorption and fluorescence contrasts simultaneously. By sharing the same laser source and objective lens, intrinsically registered photoacoustic and fluorescence images are acquired in a single scan. The micrometer resolution allows imaging of both blood and lymphatic vessels down to the capillary level. Simultaneous photoacoustic...

  4. Effect of blood contamination on results of dipstick evaluation and urine protein-to-urine creatinine ratio for urine samples from dogs and cats.

    Science.gov (United States)

    Vientós-Plotts, Aida I; Behrend, Ellen N; Welles, Elizabeth G; Chew, Dennis J; Gaillard, Philippe R; Busler, Jessica N; Lee, Hollie P

    2018-05-01

    OBJECTIVE To evaluate effects of blood contamination on dipstick results, specific gravity (SG), and urine protein-to-urine creatinine ratio (UPCR) for urine samples from dogs and cats. SAMPLE Urine samples collected from 279 dogs and 120 cats. PROCEDURES Urine pools were made for each species (dogs [n = 60] and cats [30]). Blood was added to an aliquot of a pool, and serial dilutions were prepared with the remaining urine. Color and dipstick variables were recorded, and SG and UPCR were measured. For cats, 1 set of pools was used; for dogs, 2 sets were used. Comparisons were made between undiluted urine and spiked urine samples for individual colors. Repeated-measures ANOVA on ranks was used to compare dipstick scores and UPCR results; χ 2 tests were used to compare proteinuria categorizations (nonproteinuric, borderline, or proteinuric). RESULTS Any blood in the urine resulted in significantly increased dipstick scores for blood. In both species, scores for bilirubin and ketones, pH, and SG were affected by visible blood contamination. No significant difference for the dipstick protein reagent results was evident until a sample was visibly hematuric. The UPCR was significantly increased in dark yellow samples of both species. Proteinuria categorizations differed significantly between undiluted urine and urine of all colors, except light yellow. CONCLUSIONS AND CLINICAL RELEVANCE Any degree of blood contamination affected results of dipstick analysis. Effects depended on urine color and the variable measured. Microscopic blood contamination may affect the UPCR; thus, blood contamination may be a differential diagnosis for proteinuria in yellow urine samples.

  5. Controls of nitrous oxide emission after simulated cattle urine deposition

    DEFF Research Database (Denmark)

    Baral, Khagendra Raj; Thomsen, Anton Gårde; Olesen, Jørgen E

    2014-01-01

    Urine deposited during grazing is a significant source of atmospheric nitrous oxide (N2O). The potential for N2O emissions from urine patches is high, and a better understanding of controls is needed. This study investigated soil nitrogen (N) dynamics and N2O emissions from cattle urine...

  6. Iodine and creatinine testing in urine dried on filter paper

    Energy Technology Data Exchange (ETDEWEB)

    Zava, Theodore T., E-mail: ttzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Kapur, Sonia, E-mail: soniak@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States); Zava, David T., E-mail: dzava@zrtlab.com [ZRT Laboratory, 8605 SW Creekside Place, Beaverton, OR 97008 (United States)

    2013-02-18

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R{sup 2} = 0.9483; creatinine: R{sup 2} = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs.

  7. Iodine and creatinine testing in urine dried on filter paper

    International Nuclear Information System (INIS)

    Zava, Theodore T.; Kapur, Sonia; Zava, David T.

    2013-01-01

    Highlights: ► Dried urine iodine and creatinine extract quantitatively correlates well with liquid urine. ► Filter paper strips can be easily shipped and stored. ► Urine iodine and creatinine are stable at ambient temperature when dried on filter paper. ► Dried urine iodine and creatinine are run using a 96-well format. -- Abstract: Iodine deficiency is a world-wide health problem. A simple, convenient, and inexpensive method to monitor urine iodine levels would have enormous benefit in determining an individual's recent iodine intake or in identifying populations at risk for iodine deficiency or excess. Current methods used to monitor iodine levels require collection of a large volume of urine and its transport to a testing laboratory, both of which are inconvenient and impractical in parts of the world lacking refrigerated storage and transportation. To circumvent these limitations we developed and validated methods to collect and measure iodine and creatinine in urine dried on filter paper strips. We tested liquid urine and liquid-extracted dried urine for iodine and creatinine in a 96-well format using Sandell–Kolthoff and Jaffe reactions, respectively. Our modified dried urine iodine and creatinine assays correlated well with established liquid urine methods (iodine: R 2 = 0.9483; creatinine: R 2 = 0.9782). Results demonstrate that the dried urine iodine and creatinine assays are ideal for testing the iodine status of individuals and for wide scale application in iodine screening programs

  8. Electron microscopy in metallurgy

    International Nuclear Information System (INIS)

    Loretto, M.H.

    1980-01-01

    The aim of this paper is to review briefly the contribution which (TEM) transmission electron microscopy (including high voltage electron microscopy (HVEM)) has made to metallurgy. Since it is straightforward with modern electron microscopes to extract the crystallographic information which provides the basis for any interpretation, the major problem in most metallurgical work lies in assessing how the structure (which TEM has characterised) has arisen and which properties of the specimen can be understood in terms of this structure. Radiation damage, quenching, phase transformations, grain boundaries and plastic deformation have been the main fields in which TEM has contributed significantly. After briefly summarising the role of TEM in each field, examples of recent work will be used to indicate current TEM activity in physical metallurgy. (author)

  9. Second harmonic generation microscopy

    DEFF Research Database (Denmark)

    Brüggemann, Dagmar Adeline; Brewer, Jonathan R.; Risbo, Jens

    2010-01-01

    Myofibers and collagen show non-linear optical properties enabling imaging using second harmonic generation (SHG) microscopy. The technique is evaluated for use as a tool for real-time studies of thermally induced changes in thin samples of unfixed and unstained pork. The forward and the backward...... scattered SHG light reveal complementary features of the structures of myofibers and collagen fibers. Upon heating the myofibers show no structural changes before reaching a temperature of 53 °C. At this temperature the SHG signal becomes extinct. The extinction of the SHG at 53 °C coincides with a low......-temperature endotherm peak observable in the differential scanning calorimetry (DSC) thermograms. DSC analysis of epimysium, the connective tissue layer that enfold skeletal muscles, produces one large endotherm starting at 57 °C and peaking at 59.5 °C. SHG microscopy of collagen fibers reveals a variability of thermal...

  10. Electron microscopy and diffraction

    International Nuclear Information System (INIS)

    Gjoennes, J.; Olsen, A.

    1986-01-01

    This report is a description of research activities and plans at the electron microscopy laboratorium, Physics Department, University of Oslo. Since the first electron microscope was installed in 1968, the research has covered inorganic structures, physical metallurgy, as well as theory of electron scattering and the development of methods in this field. The current plans involve efforts in the development of crystallographic and spectroscopic methods

  11. Size-exclusion chromatography-based enrichment of extracellular vesicles from urine samples

    Directory of Open Access Journals (Sweden)

    Inés Lozano-Ramos

    2015-05-01

    Full Text Available Renal biopsy is the gold-standard procedure to diagnose most of renal pathologies. However, this invasive method is of limited repeatability and often describes an irreversible renal damage. Urine is an easily accessible fluid and urinary extracellular vesicles (EVs may be ideal to describe new biomarkers associated with renal pathologies. Several methods to enrich EVs have been described. Most of them contain a mixture of proteins, lipoproteins and cell debris that may be masking relevant biomarkers. Here, we evaluated size-exclusion chromatography (SEC as a suitable method to isolate urinary EVs. Following a conventional centrifugation to eliminate cell debris and apoptotic bodies, urine samples were concentrated using ultrafiltration and loaded on a SEC column. Collected fractions were analysed by protein content and flow cytometry to determine the presence of tetraspanin markers (CD63 and CD9. The highest tetraspanin content was routinely detected in fractions well before the bulk of proteins eluted. These tetraspanin-peak fractions were analysed by cryo-electron microscopy (cryo-EM and nanoparticle tracking analysis revealing the presence of EVs.When analysed by sodium dodecyl sulphate–polyacrylamide gel electrophoresis, tetraspanin-peak fractions from urine concentrated samples contained multiple bands but the main urine proteins (such as Tamm–Horsfall protein were absent. Furthermore, a preliminary proteomic study of these fractions revealed the presence of EV-related proteins, suggesting their enrichment in concentrated samples. In addition, RNA profiling also showed the presence of vesicular small RNA species.To summarize, our results demonstrated that concentrated urine followed by SEC is a suitable option to isolate EVs with low presence of soluble contaminants. This methodology could permit more accurate analyses of EV-related biomarkers when further characterized by -omics technologies compared with other approaches.

  12. Mechanisms of urine concentration and dilution (1961)

    International Nuclear Information System (INIS)

    Morel, F.; Guinnebault, M.

    1961-01-01

    This paper is devoted to the analysis of a problem in the field of renal physiology which has shown many new developments during the course of the last few years. The following are treated successively: a) the data obtained from measurements of free water clearance and their interpretation; b) the data provided by nephron morphology and the comparative anatomy of the kidney ; c) the data relative to the existence of an intrarenal osmotic gradient; d) the principle of concentration multiplication by a counter current technique; e) the present day theory of counter current concentration of urine, and f) the physiological check on dilution and concentration mechanisms in urine. Lastly, the advantages of the modern theory and the unknown factors which remain are discussed. (authors) [fr

  13. Radioimmunoassay of urine oxytocin in man

    International Nuclear Information System (INIS)

    Zebidi, A.; Geelen, G.; Allevard, A.M.; Sempore, B.; Jarsaillon, E.; Meunier, C.; Gharib, C.

    1978-01-01

    A radioimmunoassay (RIA) for oxytocin (OT) in urine is described. 125 I-OT was prepared, and antibodies were raised in rabbits against OT coupled to bovine serumalbumine. This allowed us to set up a RIA for OT which limit of detection is 1.25 pg/tube (0.6 μU). The use of an extraction procedure using CG 50 Amberlite is essential. The recovery after extraction reaches 70.5 %. pH 5 is the optimum pH were urine samples must be stored. The superposition of the elution peak of endogenous OT on that of exogenous hormone is an argument in favour of the validity of such an extraction procedure. Daily urinary excretion of OT reaches 9.58 mU +- 3.48 in 18 healthy young men [fr

  14. [Components of urinary crystallites in urine of uric acid stone formers and its relationship with formation of stones].

    Science.gov (United States)

    Huang, Zhi-jie; Tan, Jin; Ouyang, Jian-ming

    2010-09-01

    The components, zeta potential, morphology of nanocrystallites in urines of 10 uric acid stone formers as well as their relationship with the formation of uric acid stones were comparatively studied using X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, nanoparticle size analyzer, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The urine pH of uric acid stone formers was relatively low within the range of 4.8 to 5.7. The main constituent of urinary crystallites was uric acid. Their particle size distribution was highly uneven, ranging from several nanometers to several tens of micrometers, and obvious aggregation was observed. The zeta potential of urinary crystallites in ten lithogenic patients was -6.02 mV, which was higher than that in ten normal subjects (-10.1 mV). After drug therapies (potassium citrate was taken), the urine pH value of the uric acid stone formers increased to 6.5 or so, and at this pH value most of the uric acid had changed to urate. Since the solubility of urate increased greatly than uric acid, the risk of the formation of uric acid stone reduced. The results in this paper showed that there was a close relationship among stone components, urinary crystallites composition and urine pH.

  15. Phenylbutyrate therapy for maple syrup urine disease

    OpenAIRE

    Brunetti-Pierri, Nicola; Lanpher, Brendan; Erez, Ayelet; Ananieva, Elitsa A.; Islam, Mohammad; Marini, Juan C.; Sun, Qin; Yu, Chunli; Hegde, Madhuri; Li, Jun; Wynn, R. Max; Chuang, David T.; Hutson, Susan; Lee, Brendan

    2010-01-01

    Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate in urea cycle disorder patients has been associated with a selective reduction in branched-chain amino acids (BCAA) in spite of adequate dietary protein intake. Based on this clinical observation, we investigated the potential of phenylbutyrate treatment to lower BCAA and their corresponding α-keto acids (BCKA) in patients with classic and variant late-onset forms of maple syrup urine disease (MSUD). We also performed in vitr...

  16. Environmental heat stress enhances crystallization in urine

    Science.gov (United States)

    Setyawan, H.; Pratiwi, Q. C.; Sjarifah, I.; Atmojo, T. B.; Khotijah

    2018-03-01

    Over the past several decades, agriculture and plantations have been used as the main livelihood of most of the Karanganyar residents. However, these two sources of living are now replaced by industrial areas that employ thousands of people in that district. The development of this industry triggers multiple environmental impacts, including ecosystem and temperature changes. In consequence, there is an increase in air temperature that can cause a variety of diseases, especially in the workplace. According to the International Labour Organization (ILO) data in 2013, one worker dies every 15 second due to a work accident and 160 workers are suffering from the occupational disease. In Indonesia, the incidence of crystallization in urine is actually still unknown, but it is estimated that there are 170,000 cases annually. A high temperature or called heat stress is one among many factors causing this disease to appear. The workers in the textile industry, especially in the Finishing Department Kusumahadi Co. Ltd that exposed heat stress from the finishing machines and inadequate ventilation. This hot working climate causes the human body to adapt in the form of body cooling mechanism or called sweating This adaptation can cause an increase in sweat production and decrease the production of urine. If it is not followed by consuming the recommended amount of water intake, it can result in the precipitation of body salts that, in a long time, will cause crystallization in urine. The research used the analytic observational designs for a cross-sectional study. There were 34 samples collected from 57 finishing workers. The data were analyzed using Spearman correlation test. The results showed that heat stress (p=0,015) and water intake (p=0,034) has a significant correlation with crystallization in urine.

  17. Determination of uranium in urine by fluorometry

    International Nuclear Information System (INIS)

    Afsar, M.; Aziz, A.; Mubarak, M.A.

    1978-01-01

    The report describes fluorometric determination of traces of uranium in the urine of mine workers and persons handling uranium. After preliminary treatment uranium is extracted by solvent extraction with TBP:MIBK mixtures. An aliquot of the extracted solution is fused with high carbonate flux at 650 0 C in platinum dishes. The fluorescence of fused sample is measured using a fluorometer. Various fusion parameters are discussed. The procedure for the operation and calibration of fluorometer is also described

  18. Comparison of two preparatory techniques for urine cytology.

    Science.gov (United States)

    Dhundee, J; Rigby, H S

    1990-01-01

    Two methods of preparation of urine for cytology were compared retrospectively. In method 1 cells in the urine were fixed after the preparation of the smear; in method 2 the cells were fixed before smear preparation. Urine cytology reports were correlated with subsequent histological analysis. The specificities of urine cytology using both methods were high (99%). The sensitivity using method 1 was 87%; using method 2 it was 65%. This difference was significant. The cell preparation technique therefore significantly changes the sensitivity of urine cytology. Cellular fixation after smear preparation is preferable to smear preparation after fixation. PMID:2266176

  19. Radioimmunological detection of vasopressin in urine extracts

    International Nuclear Information System (INIS)

    Buengner, R.

    1983-01-01

    After initial measures had been taken to ensure that ion exchange chromatography would yield a sufficiently high recovery of labelled and non-labelled hormone as well as to eliminate all intervening factors it was possible to use the described extraction procedure in connection with the RIA introduced by Freisenhausen et al. At the clinical level, the technique was employed to assess the post-operative release of AVP (argenine vasopressin) in 24-hour urine samples obtained from patients subjected to hypophysectomy. In a total of 10 patients, where hypophysectomy had been performed for different clinical reasons, the AVP values were seen to be significantly decreased for the first three hours after surgical intervention. They recovered slightly during the following three hours to remain at an average level of 2 pg / 400 μl urine. The extraction procedure described can be used to determine levels of AVP approaching the limit of detection - either due to large volumes of urine or very low concentrations of AVP. (orig./MG) [de

  20. Psychopathology and urine toxicology in methadone patients

    Directory of Open Access Journals (Sweden)

    Gamal Sadek

    2015-06-01

    Full Text Available Several studies reported high rates of psychiatric commorbidity among methadone patients. We examined the relationships of measures of psychopathology to outcomes of screening urine tests for cocaine, opiates, and benzodiazepines in a sample of 56 methadone patients. They also completed the Symptom Check List-90-Revised (SCL-90-R. The highest scales in the SCL-90-R profile of our patients were those indicating somatic discomfort, anger, phobic anxiety, paranoid ideation, and also obsessive-compulsive disorder symptoms (scores above the 39th percentile. The only significant correlations between urine tests and SCL-90-R psychopathology were those involving benzodiazepines: patients with urine tests positive for benzodiazepines had lower social self-confidence (r=0.48, were more obsessive-compulsive (r=0.44, reported a higher level of anger (r=0.41, of phobic tendencies (r=40, of anxiety (r=0.39, and of paranoid tendencies (r=0.38, and also reported more frequent psychotic symptoms (r=0.43.

  1. Urine sample preparation for proteomic analysis.

    Science.gov (United States)

    Olszowy, Pawel; Buszewski, Boguslaw

    2014-10-01

    Sample preparation for both environmental and more importantly biological matrices is a bottleneck of all kinds of analytical processes. In the case of proteomic analysis this element is even more important due to the amount of cross-reactions that should be taken into consideration. The incorporation of new post-translational modifications, protein hydrolysis, or even its degradation is possible as side effects of proteins sample processing. If protocols are evaluated appropriately, then identification of such proteins does not bring difficulties. However, if structural changes are provided without sufficient attention then protein sequence coverage will be reduced or even identification of such proteins could be impossible. This review summarizes obstacles and achievements in protein sample preparation of urine for proteome analysis using different tools for mass spectrometry analysis. The main aim is to present comprehensively the idea of urine application as a valuable matrix. This article is dedicated to sample preparation and application of urine mainly in novel cancer biomarkers discovery. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Stability of cannabinoids in urine in three storage temperatures.

    Science.gov (United States)

    Golding Fraga, S; Díaz-Flores Estévez, J; Díaz Romero, C

    1998-01-01

    Stability of cannabinoid compounds in urine samples were evaluated using several storage temperatures. Appreciable losses (> 22.4 percent) were observed in some urine samples, after being stored at room temperature for 10 days. Lower losses (8.1 percent) were observed when the urine samples were refrigerated for 4 weeks. The behavior of urine samples depended on the analyzed urine. This could be due to the different stability of the cannabinoids present in each urine sample. Important losses of 8.0 +/- 10.6, 15.8 +/- 4.2, and 19.6 +/- 6.7 percent were found when the urine samples were frozen during 40 days, 1 year, and 3 years, respectively. Average losses (> > 5 percent) can be observed after one day which could mainly be due to the decrease of the solubility of 11-nor-U9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) or adsorption process of cannabinoid molecules to the plastic storage containers.

  3. Albumin adsorption onto surfaces of urine collection and analysis containers.

    Science.gov (United States)

    Robinson, Mary K; Caudill, Samuel P; Koch, David D; Ritchie, James; Hortin, Glen; Eckfeldt, John H; Sandberg, Sverre; Williams, Desmond; Myers, Gary; Miller, W Greg

    2014-04-20

    Adsorption of albumin onto urine collection and analysis containers may cause falsely low concentrations. We added (125)I-labeled human serum albumin to urine and to phosphate buffered solutions, incubated them with 22 plastic container materials and measured adsorption by liquid scintillation counting. Adsorption of urine albumin (UA) at 5-6 mg/l was containers, and to instrument sample cups and showed <1% change in concentration at 5 mg/l and <0.5% change at 20 mg/l or higher concentrations. Adsorption of albumin from phosphate buffered solutions (2-28%) was larger than that from urine. Albumin adsorption differed among urine samples and plastic materials, but the total influence of adsorption was <1% for all materials and urine samples tested. Adsorption of albumin from phosphate buffered solutions was larger than that from urine and could be a limitation for preparations used as calibrators. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Detection of gonococcal antigens in urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.

    1979-01-01

    A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)

  5. Improved cancer risk stratification and diagnosis via quantitative phase microscopy (Conference Presentation)

    Science.gov (United States)

    Liu, Yang; Uttam, Shikhar; Pham, Hoa V.; Hartman, Douglas J.

    2017-02-01

    Pathology remains the gold standard for cancer diagnosis and in some cases prognosis, in which trained pathologists examine abnormality in tissue architecture and cell morphology characteristic of cancer cells with a bright-field microscope. The limited resolution of conventional microscope can result in intra-observer variation, missed early-stage cancers, and indeterminate cases that often result in unnecessary invasive procedures in the absence of cancer. Assessment of nanoscale structural characteristics via quantitative phase represents a promising strategy for identifying pre-cancerous or cancerous cells, due to its nanoscale sensitivity to optical path length, simple sample preparation (i.e., label-free) and low cost. I will present the development of quantitative phase microscopy system in transmission and reflection configuration to detect the structural changes in nuclear architecture, not be easily identifiable by conventional pathology. Specifically, we will present the use of transmission-mode quantitative phase imaging to improve diagnostic accuracy of urine cytology and the nuclear dry mass is progressively correlate with negative, atypical, suspicious and positive cytological diagnosis. In a second application, we will present the use of reflection-mode quantitative phase microscopy for depth-resolved nanoscale nuclear architecture mapping (nanoNAM) of clinically prepared formalin-fixed, paraffin-embedded tissue sections. We demonstrated that the quantitative phase microscopy system detects a gradual increase in the density alteration of nuclear architecture during malignant transformation in animal models of colon carcinogenesis and in human patients with ulcerative colitis, even in tissue that appears histologically normal according to pathologists. We evaluated the ability of nanoNAM to predict "future" cancer progression in patients with ulcerative colitis.

  6. Fourier plane imaging microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez, Daniel, E-mail: daniel.dominguez@ttu.edu; Peralta, Luis Grave de [Department of Physics, Texas Tech University, Lubbock, Texas 79409 (United States); Nano Tech Center, Texas Tech University, Lubbock, Texas 79409 (United States); Alharbi, Nouf; Alhusain, Mdhaoui [Department of Physics, Texas Tech University, Lubbock, Texas 79409 (United States); Bernussi, Ayrton A. [Nano Tech Center, Texas Tech University, Lubbock, Texas 79409 (United States); Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409 (United States)

    2014-09-14

    We show how the image of an unresolved photonic crystal can be reconstructed using a single Fourier plane (FP) image obtained with a second camera that was added to a traditional compound microscope. We discuss how Fourier plane imaging microscopy is an application of a remarkable property of the obtained FP images: they contain more information about the photonic crystals than the images recorded by the camera commonly placed at the real plane of the microscope. We argue that the experimental results support the hypothesis that surface waves, contributing to enhanced resolution abilities, were optically excited in the studied photonic crystals.

  7. Correlative Stochastic Optical Reconstruction Microscopy and Electron Microscopy

    Science.gov (United States)

    Kim, Doory; Deerinck, Thomas J.; Sigal, Yaron M.; Babcock, Hazen P.; Ellisman, Mark H.; Zhuang, Xiaowei

    2015-01-01

    Correlative fluorescence light microscopy and electron microscopy allows the imaging of spatial distributions of specific biomolecules in the context of cellular ultrastructure. Recent development of super-resolution fluorescence microscopy allows the location of molecules to be determined with nanometer-scale spatial resolution. However, correlative super-resolution fluorescence microscopy and electron microscopy (EM) still remains challenging because the optimal specimen preparation and imaging conditions for super-resolution fluorescence microscopy and EM are often not compatible. Here, we have developed several experiment protocols for correlative stochastic optical reconstruction microscopy (STORM) and EM methods, both for un-embedded samples by applying EM-specific sample preparations after STORM imaging and for embedded and sectioned samples by optimizing the fluorescence under EM fixation, staining and embedding conditions. We demonstrated these methods using a variety of cellular targets. PMID:25874453

  8. The Urine Proteome as a Biomarker of Radiation Injury

    Science.gov (United States)

    Sharma, Mukut; Halligan, Brian D.; Wakim, Bassam T.; Savin, Virginia J.; Cohen, Eric P.; Moulder, John E.

    2009-01-01

    Terrorist attacks or nuclear accidents could expose large numbers of people to ionizing radiation, and early biomarkers of radiation injury would be critical for triage, treatment and follow-up of such individuals. However, no such biomarkers have yet been proven to exist. We tested the potential of high throughput proteomics to identify protein biomarkers of radiation injury after total body X-ray irradiation in a rat model. Subtle functional changes in the kidney are suggested by an increased glomerular permeability for macromolecules measured within 24 hours after TBI. Ultrastructural changes in glomerular podocytes include partial loss of the interdigitating organization of foot processes. Analysis of urine by LC-MS/MS and 2D-GE showed significant changes in the urine proteome within 24 hours after TBI. Tissue kallikrein 1-related peptidase, cysteine proteinase inhibitor cystatin C and oxidized histidine were found to be increased while a number of proteinase inhibitors including kallikrein-binding protein and albumin were found to be decreased post-irradiation. Thus, TBI causes immediately detectable changes in renal structure and function and in the urinary protein profile. This suggests that both systemic and renal changes are induced by radiation and it may be possible to identify a set of biomarkers unique to radiation injury. PMID:19746194

  9. Determination of radium in urine; Dosage du radium dans l'urine

    Energy Technology Data Exchange (ETDEWEB)

    Fourniguet, H; Jeanmaire, L; Jammet, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    A procedure for the quantitative analysis of radium in urine is described. The radium is carried by a barium sulfate precipitate. The precipitate is mixed with zinc sulfide and the activity measured by scintillation counting. It is thus possible to detect an amount of radium less than 1 pico-curie in the sample. (author) [French] Cet article decrit une technique de dosage du radium dans l'urine. Le radium entraine par un precipite de sulfate de baryum est compte par scintillation apres melange du precipite avec du sulfure de zinc. Cette methode permet de deceler moins de 1 picocurie de radium dans l'echantillon. (auteur)

  10. Plasmonics Enhanced Smartphone Fluorescence Microscopy

    KAUST Repository

    Wei, Qingshan; Acuna, Guillermo; Kim, Seungkyeum; Vietz, Carolin; Tseng, Derek; Chae, Jongjae; Shir, Daniel; Luo, Wei; Tinnefeld, Philip; Ozcan, Aydogan

    2017-01-01

    Smartphone fluorescence microscopy has various applications in point-of-care (POC) testing and diagnostics, ranging from e.g., quantification of immunoassays, detection of microorganisms, to sensing of viruses. An important need in smartphone-based microscopy and sensing techniques is to improve the detection sensitivity to enable quantification of extremely low concentrations of target molecules. Here, we demonstrate a general strategy to enhance the detection sensitivity of a smartphone-based fluorescence microscope by using surface-enhanced fluorescence (SEF) created by a thin metal-film. In this plasmonic design, the samples are placed on a silver-coated glass slide with a thin spacer, and excited by a laser-diode from the backside through a glass hemisphere, generating surface plasmon polaritons. We optimized this mobile SEF system by tuning the metal-film thickness, spacer distance, excitation angle and polarization, and achieved ~10-fold enhancement in fluorescence intensity compared to a bare glass substrate, which enabled us to image single fluorescent particles as small as 50 nm in diameter and single quantum-dots. Furthermore, we quantified the detection limit of this platform by using DNA origami-based brightness standards, demonstrating that ~80 fluorophores per diffraction-limited spot can be readily detected by our mobile microscope, which opens up new opportunities for POC diagnostics and sensing applications in resource-limited-settings.

  11. Multifunctional scanning ion conductance microscopy

    Science.gov (United States)

    Page, Ashley; Unwin, Patrick R.

    2017-01-01

    Scanning ion conductance microscopy (SICM) is a nanopipette-based technique that has traditionally been used to image topography or to deliver species to an interface, particularly in a biological setting. This article highlights the recent blossoming of SICM into a technique with a much greater diversity of applications and capability that can be used either standalone, with advanced control (potential–time) functions, or in tandem with other methods. SICM can be used to elucidate functional information about interfaces, such as surface charge density or electrochemical activity (ion fluxes). Using a multi-barrel probe format, SICM-related techniques can be employed to deposit nanoscale three-dimensional structures and further functionality is realized when SICM is combined with scanning electrochemical microscopy (SECM), with simultaneous measurements from a single probe opening up considerable prospects for multifunctional imaging. SICM studies are greatly enhanced by finite-element method modelling for quantitative treatment of issues such as resolution, surface charge and (tip) geometry effects. SICM is particularly applicable to the study of living systems, notably single cells, although applications extend to materials characterization and to new methods of printing and nanofabrication. A more thorough understanding of the electrochemical principles and properties of SICM provides a foundation for significant applications of SICM in electrochemistry and interfacial science. PMID:28484332

  12. Plasmonics Enhanced Smartphone Fluorescence Microscopy

    KAUST Repository

    Wei, Qingshan

    2017-05-12

    Smartphone fluorescence microscopy has various applications in point-of-care (POC) testing and diagnostics, ranging from e.g., quantification of immunoassays, detection of microorganisms, to sensing of viruses. An important need in smartphone-based microscopy and sensing techniques is to improve the detection sensitivity to enable quantification of extremely low concentrations of target molecules. Here, we demonstrate a general strategy to enhance the detection sensitivity of a smartphone-based fluorescence microscope by using surface-enhanced fluorescence (SEF) created by a thin metal-film. In this plasmonic design, the samples are placed on a silver-coated glass slide with a thin spacer, and excited by a laser-diode from the backside through a glass hemisphere, generating surface plasmon polaritons. We optimized this mobile SEF system by tuning the metal-film thickness, spacer distance, excitation angle and polarization, and achieved ~10-fold enhancement in fluorescence intensity compared to a bare glass substrate, which enabled us to image single fluorescent particles as small as 50 nm in diameter and single quantum-dots. Furthermore, we quantified the detection limit of this platform by using DNA origami-based brightness standards, demonstrating that ~80 fluorophores per diffraction-limited spot can be readily detected by our mobile microscope, which opens up new opportunities for POC diagnostics and sensing applications in resource-limited-settings.

  13. PERAWATAN GIGI PADA ANAK DENGAN MAPLE SYRUP URINE DISEASE (LAPORAN KASUS

    Directory of Open Access Journals (Sweden)

    Tri Fajari

    2015-07-01

    Full Text Available Maple Syrup Urine Disease is a disparity of leusin decarboxilation, and isoleusin of valin defect that is synthesized with complex enzyme systems. It is a rare disease and represents disparity. In some cases can generate ketosis that grows according to health change and can cause comma. Dental treatment of a child with Maple Syrup Urine Disease was not clearly mentioned, there is only a factor such as infection, which is very dangerous at any age, and can generate irregular metabolism. Dental treatment of a child with Maple Syrup Urine Disease accompanied by mental retardation must be done continuously to avoid infection that can result in the death of the patients.

  14. Urine 1,6-Hexamethylene Diamine (HDA) Levels Among Workers Exposed to 1,6-Hexamethylene Diisocyanate (HDI)

    OpenAIRE

    Gaines, Linda G. T.; Fent, Kenneth W.; Flack, Sheila L.; Thomasen, Jennifer M.; Ball, Louise M.; Richardson, David B.; Ding, Kai; Whittaker, Stephen G.; Nylander-french, Leena A.

    2010-01-01

    Urinary 1,6-hexamethylene diamine (HDA) may serve as a biomarker for systemic exposure to 1,6-hexamethylene diisocyanate (HDI) in occupationally exposed populations. However, the quantitative relationships between dermal and inhalation exposure to HDI and urine HDA levels have not been established. We measured acid-hydrolyzed urine HDA levels along with dermal and breathing-zone levels of HDI in 48 automotive spray painters. These measurements were conducted over the course of an entire workd...

  15. Short-term emissions of ammonia and carbon dioxide from cattle urine contaminated tropical grassland microcosm.

    Science.gov (United States)

    Majumdar, Deepanjan; Patel, Manoj; Drabar, Reena; Vyas, Manish

    2006-11-01

    The study was designed to understand the emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) from a single cattle urination event on a tropical grassland and underline the significance of the emissions in the context of huge animal population grazing on large pasture areas in some countries. Emissions of ammonia (NH(3)) and carbon dioxide (CO(2)) were monitored for three weeks from a tropical grassland (dominated by Cynodon dactylon Pers.) microcosm contaminated with cow and buffalo urine. The grassland microcosms were treated with urine (50 and 100 ml of each) only once and irrigated with water once every week. Ammonia was sampled by an automatic sampling system comprising of a vacuum pump, three-way stopcocks and rubber tubing and an impinger containing suitable absorbing solution (H(2)SO(4)), connected to the tubing suitably. The sampled gas, after sucked by the vacuum pump and absorbed in H(2)SO(4), was allowed to enter the closed microcosm again maintaining internal pressure of the microcosm. Carbon dioxide was sampled by absorption in an alkali (NaOH) trap inside the microcosm. Both NH(3) and CO(2) emissions were highly variable temporally and there was no continuous increasing or decreasing emission trend with time. Respectively, 45 and 46% of total NH(3)-N were emitted within first 48 h from 50 and 100 ml cow urine application while the corresponding values for buffalo urine were 34 and 32%. Total NH(3)-N emissions, integrated for sampling days (i.e. 1, 2, 3, 4, 6, 15, 18 and 21st) were 11 and 6% in cow and 8 and 5% in buffalo urine, of the total-N added through 50 and 100 ml urine samples. Carbon dioxide emissions were standardized at 25 degrees C by using a suitable formula which were lower than actual emissions at actual soil temperature (> 25 degrees C). Carbon dioxide emission rates were classified on the basis of soil repiratory classification and classes ranged from moderately low soil activity up to unusually high soil activity, the latter

  16. Spatially resolved analyses of uranium species using a coupled system made up of confocal laser-scanning microscopy (CLSM) and laser induced fluorescence spectroscopy (LIFS)

    International Nuclear Information System (INIS)

    Brockmann, S.; Grossmann, K.; Arnold, T.

    2014-01-01

    The fluorescent properties of uranium when excited by UV light are used increasingly for spectroscope analyses of uranium species within watery samples. Here, alongside the fluorescent properties of the hexavalent oxidation phases, the tetra and pentavalent oxidation phases also play an increasingly important role. The detection of fluorescent emission spectrums on solid and biological samples using (time-resolved) laser induced fluorescence spectroscopy (TRLFS or LIFS respectively) has, however, the disadvantage that no statements regarding the spatial localisation of the uranium can be made. However, particularly in complex, biological samples, such statements on the localisation of the uranium enrichment in the sample are desired, in order to e.g. be able to distinguish between intra and extra-cellular uranium bonds. The fluorescent properties of uranium (VI) compounds and minerals can also be used to detect their localisation within complex samples. So the application of fluorescent microscopic methods represents one possibility to localise and visualise uranium precipitates and enrichments in biological samples, such as biofilms or cells. The confocal laser-scanning microscopy (CLSM) is especially well suited to this purpose. Coupling confocal laser-scanning microscopy (CLSM) with laser induced fluorescence spectroscopy (LIFS) makes it possible to localise and visualise fluorescent signals spatially and three-dimensionally, while at the same time being able to detect spatially resolved, fluorescent-spectroscopic data. This technology is characterised by relatively low detection limits from up to 1.10 -6 M for uranium (VI) compounds within the confocal volume. (orig.)

  17. Detection of charge storage on molecular thin films of tris(8-hydroxyquinoline) aluminum (Alq3) by Kelvin force microscopy: a candidate system for high storage capacity memory cells.

    Science.gov (United States)

    Paydavosi, Sarah; Aidala, Katherine E; Brown, Patrick R; Hashemi, Pouya; Supran, Geoffrey J; Osedach, Timothy P; Hoyt, Judy L; Bulović, Vladimir

    2012-03-14

    Retention and diffusion of charge in tris(8-hydroxyquinoline) aluminum (Alq(3)) molecular thin films are investigated by injecting electrons and holes via a biased conductive atomic force microscopy tip into the Alq(3) films. After the charge injection, Kelvin force microscopy measurements reveal minimal changes with time in the spatial extent of the trapped charge domains within Alq(3) films, even for high hole and electron densities of >10(12) cm(-2). We show that this finding is consistent with the very low mobility of charge carriers in Alq(3) thin films (<10(-7) cm(2)/(Vs)) and that it can benefit from the use of Alq(3) films as nanosegmented floating gates in flash memory cells. Memory capacitors using Alq(3) molecules as the floating gate are fabricated and measured, showing durability over more than 10(4) program/erase cycles and the hysteresis window of up to 7.8 V, corresponding to stored charge densities as high as 5.4 × 10(13) cm(-2). These results demonstrate the potential for use of molecular films in high storage capacity nonvolatile memory cells. © 2012 American Chemical Society

  18. Advanced Microscopy of Microbial Cells

    DEFF Research Database (Denmark)

    Haagensen, Janus Anders Juul; Regenberg, Birgitte; Sternberg, Claus

    2011-01-01

    Growing awareness of heterogeneity in cells of microbial populations has emphasized the importance of advanced microscopy for visualization and understanding of the molecular mechanisms underlying cell-to-cell variation. In this review, we highlight some of the recent advances in confocal...... microscopy, super-resolution optical microscopy (STED, SIM, PALM) as well as atomic force microscopy and Raman spectroscopy. Using examples of bistability in microbial populations as well as biofilm development and differentiation in bacterial and yeast consortia, we demonstrate the importance of microscopy...

  19. Urine drug screening in the medical setting.

    Science.gov (United States)

    Hammett-Stabler, Catherine A; Pesce, Amadeo J; Cannon, Donald J

    2002-01-01

    The term drug screen is a misnomer since it implies screening for all drugs, which is not possible. Current practice is to limit the testing to the examination of serum for several drugs such as ethanol, acetaminophen, salicylate, and of urine for several specific drugs or classes of drugs. In the emergency setting the screen should be performed in less than one hour. Controversies continue to exist regarding the value of urine drug testing in the medical setting. The reasons for these include the drugs involved, the sample, the methods utilized to perform the tests, and the level of understanding of the physician using the data, all of which are closely related to the other. Current automated methods provide rapid results demanded in emergency situations, but are often designed for, or adapted from, workplace testing and are not necessarily optimized for clinical applications. Furthermore, the use of these methods without consideration of the frequency in which the drugs are found in a given area is not cost-effective. The laboratory must understand the limitations of the assays used and provide this information to the physician. Additionally, the laboratory and the physicians using the data must cooperate to determine which drugs are appropriate and necessary to measure for their institution and clinical setting. In doing so it should be remembered that for many drugs, the sample, urine, contains the end product(s) of drug metabolism, not the parent drug. Furthermore, it is necessary to understand the pharmacokinetic parameters of the drug of interest when interpreting data. Finally, while testing for some drugs may not appear cost-effective, the prevention or reduction of morbidity and mortality may offset any laboratory costs. While the literature is replete with studies concerning new methods and a few regarding physician understanding, there are none that we could find that thoroughly, objectively, and fully addressed the issues of utility and cost-effectiveness.

  20. Identification and testing of early indicators for N leaching from urine patches.

    Science.gov (United States)

    Vogeler, Iris; Cichota, Rogerio; Snow, Val

    2013-11-30

    Nitrogen leaching from urine patches has been identified as a major source of nitrogen loss under intensive grazing dairy farming. Leaching is notoriously variable, influenced by management, soil type, year-to-year variation in climate and timing and rate of urine depositions. To identify early indicators for the risk of N leaching from urine patches for potential usage in a precision management system, we used the simulation model APSIM (Agricultural Production Systems SIMulator) to produce an extensive N leaching dataset for the Waikato region of New Zealand. In total, nearly forty thousand simulation runs with different combinations of soil type and urine deposition times, in 33 different years, were done. The risk forecasting indicators were chosen based on their practicality: being readily measured on farm (soil water content, temperature and pasture growth) or that could be centrally supplied to farms (such as actual and forecast weather data). The thresholds of the early indicators that are used to forecast a period for high risk of N leaching were determined via classification and regression tree analysis. The most informative factors were soil temperature, pasture dry matter production, and average soil water content in the top soil over the two weeks prior to the urine N application event. Rainfall and air temperature for the two weeks following urine deposition were also important to fine-tune the predictions. The identified early indicators were then tested for their potential to predict the risk of N leaching in two typical soils from the Waikato region in New Zealand. The accuracy of the predictions varied with the number of indicators, the soil type and the risk level, and the number of correct predictions ranged from about 45 to over 90%. Further expansion and fine-tuning of the indicators and the development of a practical N risk tool based on these indicators is needed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Inventing urine incontinence devices for women.

    Science.gov (United States)

    Pieper, B; Cleland, V; Johnson, D E; O'Reilly, J L

    1989-01-01

    Nurses have long been aware of the devastating effects of urinary incontinence on women. Although women may find diapers, pads and protective clothing valuable protection, there are few options for a continuous wear, external urine incontinence device (EUID). Inventors have attempted to develop an EUID since ancient times; the first United States patent for an EUID was awarded in 1949. The purpose of this paper is to review technological considerations for development of an external urinary incontinence device for women. Patents and products illustrate the considerations.

  2. Urine protein concentration estimation for biomarker discovery

    OpenAIRE

    Mistry, Hiten D.; Bramham, Kate; Weston, Andrew; Ward, Malcolm; Thompson, Andrew; Chappell, Lucy C.

    2013-01-01

    Recent advances have been made in the study of urinary proteomics as a diagnostic tool for renal disease and pre-eclampsia which requires accurate measurement of urinary protein. We compared different protein assays (Bicinchoninic acid (BCA), Lowry and Bradford) against the ‘gold standard’ amino-acid assay in urine from 43 women (8 non-pregnant, 34 pregnant, including 8 with pre-eclampsia. BCA assay was superior to both Lowry and Bradford assays (Bland Altman bias: 0.08) compared to amino-aci...

  3. The radioimmunological determination of vasopressin in urine

    International Nuclear Information System (INIS)

    Horn, M.J. van der.

    1981-01-01

    This thesis describes the development of a radioimmunoassay (RIA) for antidiuretic hormone (ADH) or vasopressin, which can be used for the quantitative measurement of the urinary excretion of the hormone in man during physiological and pathological conditions. The final RIA method, using approximately 5 pg 125 I-AVP diluted (1 : 50,000) antiserum 121 and charcoal-dextran separation of the antibody-bound and free fractions, is found to be specific for vasopressin and closely related substances; the sensitivity is 9 pg. The validity is demonstrated and the results of measurements of vasopressin excretion in urine from 39 normal subjects, including 4 children are presented. (Auth.)

  4. Psychogenic urine retention during doping controls

    DEFF Research Database (Denmark)

    Elbe, Anne-Marie; Schlegel, Marius M.; Brand, Ralf

    2012-01-01

    relation to recovery, performance, and self-perception of professionalism and athletic excellence. Furthermore, a scale developed especially for the close description and measurement of PURD is presented. A questionnaire was used for measuring paruresis. The results are based on two online and one paper...... and pencil study involving 222 German-speaking athletes from various sports. The results indicate that 60% of these athletes have experienced psychogenic urine retention during doping controls, with only 39% of them showing symptoms of paruresis. PURD impacts athlete recovery and self-perception...

  5. Hyperspectral light sheet microscopy

    Science.gov (United States)

    Jahr, Wiebke; Schmid, Benjamin; Schmied, Christopher; Fahrbach, Florian O.; Huisken, Jan

    2015-09-01

    To study the development and interactions of cells and tissues, multiple fluorescent markers need to be imaged efficiently in a single living organism. Instead of acquiring individual colours sequentially with filters, we created a platform based on line-scanning light sheet microscopy to record the entire spectrum for each pixel in a three-dimensional volume. We evaluated data sets with varying spectral sampling and determined the optimal channel width to be around 5 nm. With the help of these data sets, we show that our setup outperforms filter-based approaches with regard to image quality and discrimination of fluorophores. By spectral unmixing we resolved overlapping fluorophores with up to nanometre resolution and removed autofluorescence in zebrafish and fruit fly embryos.

  6. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  7. Ammonia recovery from urine in a scaled-up Microbial Electrolysis Cell

    NARCIS (Netherlands)

    Zamora, Patricia; Georgieva, Tanya; Heijne, ter Annemiek; Sleutels, Tom H.J.A.; Jeremiasse, Adriaan W.; Saakes, Michel; Buisman, Cees J.N.; Kuntke, Philipp

    2017-01-01

    A two-step treatment system for nutrient and energy recovery from urine was successfully operated for six months. In the first step, phosphorus (P) was recovered as struvite (magnesium ammonium phosphate or MAP) in a MAP reactor. The effluent of this MAP reactor was used for total ammonia-nitrogen

  8. Platinum replica electron microscopy: Imaging the cytoskeleton globally and locally.

    Science.gov (United States)

    Svitkina, Tatyana M

    2017-05-01

    Structural studies reveal how smaller components of a system work together as a whole. However, combining high resolution of details with full coverage of the whole is challenging. In cell biology, light microscopy can image many cells in their entirety, but at a lower resolution, whereas electron microscopy affords very high resolution, but usually at the expense of the sample size and coverage. Structural analyses of the cytoskeleton are especially demanding, because cytoskeletal networks are unresolvable by light microscopy due to their density and intricacy, whereas their proper preservation is a challenge for electron microscopy. Platinum replica electron microscopy can uniquely bridge the gap between the "comfort zones" of light and electron microscopy by allowing high resolution imaging of the cytoskeleton throughout the entire cell and in many cells in the population. This review describes the principles and applications of platinum replica electron microscopy for studies of the cytoskeleton. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Progress in the Correlative Atomic Force Microscopy and Optical Microscopy

    Directory of Open Access Journals (Sweden)

    Lulu Zhou

    2017-04-01

    Full Text Available Atomic force microscopy (AFM has evolved from the originally morphological imaging technique to a powerful and multifunctional technique for manipulating and detecting the interactions between molecules at nanometer resolution. However, AFM cannot provide the precise information of synchronized molecular groups and has many shortcomings in the aspects of determining the mechanism of the interactions and the elaborate structure due to the limitations of the technology, itself, such as non-specificity and low imaging speed. To overcome the technical limitations, it is necessary to combine AFM with other complementary techniques, such as fluorescence microscopy. The combination of several complementary techniques in one instrument has increasingly become a vital approach to investigate the details of the interactions among molecules and molecular dynamics. In this review, we reported the principles of AFM and optical microscopy, such as confocal microscopy and single-molecule localization microscopy, and focused on the development and use of correlative AFM and optical microscopy.

  10. The Association Between Urine Output, Creatinine Elevation, and Death.

    Science.gov (United States)

    Engoren, Milo; Maile, Michael D; Heung, Michael; Jewell, Elizabeth S; Vahabzadeh, Christie; Haft, Jonathan W; Kheterpal, Sachin

    2017-04-01

    Acute kidney injury can be defined by a fall in urine output, and urine output criteria may be more sensitive in identifying acute kidney injury than traditional serum creatinine criteria. However, as pointed out in the Kidney Disease Improving Global Outcome guidelines, the association of urine output with subsequent creatinine elevations and death is poorly characterized. The purpose of this study was to determine what degrees of reduced urine output are associated with subsequent creatinine elevation and death. This was a retrospective cohort study of adult patients (age ≥18 years) cared for in a cardiovascular intensive care unit after undergoing cardiac operations in a tertiary care university medical center. All adult patients who underwent cardiac operations and were not receiving dialysis preoperatively were studied. The development of acute kidney injury was defined as an increase in creatinine of more than 0.3 mg/dL or by more than 50% above baseline by postoperative day 3. Acute kidney injury developed in 1,061 of 4,195 patients (25%). Urine output had moderate discrimination in predicting subsequent acute kidney injury (C statistic = .637 ± .054). Lower urine output and longer duration of low urine output were associated with greater odds of developing acute kidney injury and death. We found that there is similar accuracy in using urine output corrected for actual, ideal, or adjusted weight to discriminate future acute kidney injury by creatinine elevation and recommend using actual weight for its simplicity. We also found that low urine output is associated with subsequent acute kidney injury and that the association is greater for lower urine output and for low urine output of longer durations. Low urine output (creatinine elevation, is independently associated with mortality. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Determination of iodine in human milk and urine | Ayodele | Ife ...

    African Journals Online (AJOL)

    Physiological concentrations of iodine were determined in milk and urine. Recovery studies are reported along with results for the analysis of milk and urine samples. Iodine contents ranged from 10 - 110 (mean 52.88 ± 22.60mg/l) and 10 - 90 (mean 27.64 ±16.70) g/l in milk and urine respectively. A significant difference is ...

  12. High-speed atomic force microscopy combined with inverted optical microscopy for studying cellular events.

    OpenAIRE

    Suzuki, Yuki; Sakai, Nobuaki; Yoshida, Aiko; Uekusa, Yoshitsugu; Yagi, Akira; Imaoka, Yuka; Ito, Shuichi; Karaki, Koichi; Takeyasu, Kunio

    2013-01-01

    A hybrid atomic force microscopy (AFM)-optical fluorescence microscopy is a powerful tool for investigating cellular morphologies and events. However, the slow data acquisition rates of the conventional AFM unit of the hybrid system limit the visualization of structural changes during cellular events. Therefore, high-speed AFM units equipped with an optical/fluorescence detection device have been a long-standing wish. Here we describe the implementation of high-speed AFM coupled with an optic...

  13. Bisphenol A levels in human urine.

    Science.gov (United States)

    Matsumoto, Akiko; Kunugita, Naoki; Kitagawa, Kyoko; Isse, Toyohi; Oyama, Tsunehiro; Foureman, Gary L; Morita, Masatoshi; Kawamoto, Toshihiro

    2003-01-01

    The estrogenic effects of bisphenol A (BPA) have been reported in human cells (E-screen assays) and in (italic)in vivo(/italic) studies of rodents, although the latter reports remain controversial, as do the exposure levels and adverse health effects of BPA in humans. In this study we report on an analytical high-performance liquid chromatography/fluorescence method for BPA and its conjugate in human urine and on the application of this method in two student cohorts. Urine, along with information on smoking, alcohol intake, and coffee/tea consumption, was collected in two different years from two different groups of university students, 50 in 1992 and 56 in 1999. Overall, the urinary BPA levels in the students in 1992 were significantly higher than were those in 1999. The BPA levels were also positively correlated with coffee and tea consumption in the 1992 cohort but not in the 1999 cohort. We speculate that recent changes made in Japan regarding the interior coating of cans used to package these beverages may partly explain these findings. PMID:12515686

  14. Study in electron microscopy of the formation of the hybrid layer using adhesive systems One Coat and Experimental (EXL 759), at the Facultad de Odontologia of the Universidad de Costa Rica

    International Nuclear Information System (INIS)

    Santamaria Guzman, S. Marcela; Guevara Lopez, Rodrigo

    2012-01-01

    The formation of the hybrid layer is observed in dental pieces in vitro, utilizing conventional adhesives systems and of self etching with different times of acid etching, by applying of electron microscopy. Samples of dental pieces are prepared utilizing conventional adhesive systems as Single Bond 2 of 3M, One Coat of Coltene and the adhesive self etching Experimental (EXL 759) of 3M. Samples of dental pieces collected have been molars recently extracted and later stored in jars with water. Samples prepared with the adhesive systems are observed in the electron microscope to obtain images of the hybrid layers formed. The hybrid layers formed are compared observing the photographs of the images obtained in the electron microscope. The adhesive system that has allowed the formation of a hybrid layer more convenient is determined. The time of acid etching is determined and has interfered in the formation of a hybrid layer more stable [es

  15. Alpha spectrum analysis of 241Am in the urine

    International Nuclear Information System (INIS)

    Qiu Yongmei; Yang Yong

    2006-10-01

    With 241 Am as indicator, americium in the urine was concentrated by the method of codeposition, then it was purified by the method of anion exchange, at last, the americium was electroplated. 241 Am in the urine was analysed by six channel low level alpha measuring instrument and Alpha Spectrometer. The results show that the recovering ratio is beyond 60% under the condition that the indicator added to the urine is at the level of mBq. So, 241 Am in the urine can be quantitatively analysed by this method, uncertainty of the result is under 40%, detection limit of the instrument is under 10 -4 Bq. (authors)

  16. Ketones in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Ketones: Urine; p. 351. Joslin Diabetes ...

  17. Blood in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Hemoglobin, Urine; p. 325. Lab Tests ...

  18. Use of urine in snow to indicate condition of wolves

    Science.gov (United States)

    Mech, L.D.; Seal, U.S.; DelGiudice, G.D.

    1987-01-01

    Urine deposited in snow by wild gray wolves (Canis lupus) and by fed and fasted captive wolves was analyzed for urea nitrogen, calcium, sodium, potassium, and creatinine. Ratios of the elements with creatinine were considerably higher for fed than for fasted animals, and ratios for fed wolves compared favorably with ratios from wolf urine in snow along trails leading from kills. Thus, wolf urine in the snow can indicate whether wolves have fed recently, and a series of such urine collections from any given pack can indicate relative nutritional state.

  19. Direct assay for urine cortisol with cortisol kit TFB

    Energy Technology Data Exchange (ETDEWEB)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki [Yamagata Univ. (Japan). Hospital

    2002-05-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 {mu}l of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  20. Direct assay for urine cortisol with cortisol kit TFB

    International Nuclear Information System (INIS)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki

    2002-01-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 μl of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  1. Property changes of urinary nanocrystallites and urine of uric acid stone formers after taking potassium citrate

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Guang-Na; Ouyang, Jian-Ming, E-mail: toyjm@jnu.edu.cn; Xue, Jun-Fa; Shang, Yun-Feng

    2013-10-15

    The property changes of urinary nanocrystallites in 20 cases of uric acid (UA) stone formers after 1 week of potassium citrate (K{sub 3}cit) intake were comparatively studied by X-ray diffraction analysis, Fourier transform infrared spectroscopy, nanoparticle size analysis, and transmission electron microscopy. Before K{sub 3}cit intake, the urinary crystallites mainly contained UA and calcium oxalate. After K{sub 3}cit intake, the components changed to urate and UA; the qualities, species, and amounts of aggregated crystallites decreased; urine pH, citrate, and glycosaminoglycan excretions increased; and UA excretion, Zeta potential, and crystallite size decreased. The stability of crystallites followed the order: controls > patients after taking K{sub 3}cit > patients before taking K{sub 3}cit. Therefore, the components of urinary stones were closely related to the components of urinary crystallites. - Graphical abstract: The relationships among stone components, urinary crystallite components, and urine pH were established. The crystallites stability order was: controls > patients after taking K{sub 3}cit > patients before taking K{sub 3}cit. Highlights: • Urine crystallite property of uric acid stone former after K{sub 3}cit intake was studied. • The components of crystallites in urine are closely related to type of stones. • After K{sub 3}cit intake the qualities and species of crystallites decreased. • After K{sub 3}cit intake the amount of aggregated crystallites decreased. • The stability of urinary crystallites of UA patients increased after taking K{sub 3}cit.

  2. Kelvin probe force microscopy in liquid using electrochemical force microscopy

    Directory of Open Access Journals (Sweden)

    Liam Collins

    2015-01-01

    Full Text Available Conventional closed loop-Kelvin probe force microscopy (KPFM has emerged as a powerful technique for probing electric and transport phenomena at the solid–gas interface. The extension of KPFM capabilities to probe electrostatic and electrochemical phenomena at the solid–liquid interface is of interest for a broad range of applications from energy storage to biological systems. However, the operation of KPFM implicitly relies on the presence of a linear lossless dielectric in the probe–sample gap, a condition which is violated for ionically-active liquids (e.g., when diffuse charge dynamics are present. Here, electrostatic and electrochemical measurements are demonstrated in ionically-active (polar isopropanol, milli-Q water and aqueous NaCl and ionically-inactive (non-polar decane liquids by electrochemical force microscopy (EcFM, a multidimensional (i.e., bias- and time-resolved spectroscopy method. In the absence of mobile charges (ambient and non-polar liquids, KPFM and EcFM are both feasible, yielding comparable contact potential difference (CPD values. In ionically-active liquids, KPFM is not possible and EcFM can be used to measure the dynamic CPD and a rich spectrum of information pertaining to charge screening, ion diffusion, and electrochemical processes (e.g., Faradaic reactions. EcFM measurements conducted in isopropanol and milli-Q water over Au and highly ordered pyrolytic graphite electrodes demonstrate both sample- and solvent-dependent features. Finally, the feasibility of using EcFM as a local force-based mapping technique of material-dependent electrostatic and electrochemical response is investigated. The resultant high dimensional dataset is visualized using a purely statistical approach that does not require a priori physical models, allowing for qualitative mapping of electrostatic and electrochemical material properties at the solid–liquid interface.

  3. Bessel light sheet structured illumination microscopy

    Science.gov (United States)

    Noshirvani Allahabadi, Golchehr

    Biomedical study researchers using animals to model disease and treatment need fast, deep, noninvasive, and inexpensive multi-channel imaging methods. Traditional fluorescence microscopy meets those criteria to an extent. Specifically, two-photon and confocal microscopy, the two most commonly used methods, are limited in penetration depth, cost, resolution, and field of view. In addition, two-photon microscopy has limited ability in multi-channel imaging. Light sheet microscopy, a fast developing 3D fluorescence imaging method, offers attractive advantages over traditional two-photon and confocal microscopy. Light sheet microscopy is much more applicable for in vivo 3D time-lapsed imaging, owing to its selective illumination of tissue layer, superior speed, low light exposure, high penetration depth, and low levels of photobleaching. However, standard light sheet microscopy using Gaussian beam excitation has two main disadvantages: 1) the field of view (FOV) of light sheet microscopy is limited by the depth of focus of the Gaussian beam. 2) Light-sheet images can be degraded by scattering, which limits the penetration of the excitation beam and blurs emission images in deep tissue layers. While two-sided sheet illumination, which doubles the field of view by illuminating the sample from opposite sides, offers a potential solution, the technique adds complexity and cost to the imaging system. We investigate a new technique to address these limitations: Bessel light sheet microscopy in combination with incoherent nonlinear Structured Illumination Microscopy (SIM). Results demonstrate that, at visible wavelengths, Bessel excitation penetrates up to 250 microns deep in the scattering media with single-side illumination. Bessel light sheet microscope achieves confocal level resolution at a lateral resolution of 0.3 micron and an axial resolution of 1 micron. Incoherent nonlinear SIM further reduces the diffused background in Bessel light sheet images, resulting in

  4. Lithium-induced NDI: acetazolamide reduces polyuria but does not improve urine concentrating ability.

    Science.gov (United States)

    de Groot, Theun; Doornebal, Joan; Christensen, Birgitte M; Cockx, Simone; Sinke, Anne P; Baumgarten, Ruben; Bedford, Jennifer J; Walker, Robert J; Wetzels, Jack F M; Deen, Peter M T

    2017-09-01

    Lithium is the mainstay treatment for patients with bipolar disorder, but it generally causes nephrogenic diabetes insipidus (NDI), a disorder in which the renal urine concentrating ability has become vasopressin insensitive. Li-NDI is caused by lithium uptake by collecting duct principal cells and downregulation of aquaporin-2 (AQP2) water channels, which are essential for water uptake from tubular urine. Recently, we found that the prophylactic administration of acetazolamide to mice effectively attenuated Li-NDI. To evaluate whether acetazolamide might benefit lithium-treated patients, we administered acetazolamide to mice with established Li-NDI and six patients with a lithium-induced urinary concentrating defect. In mice, acetazolamide partially reversed lithium-induced polyuria and increased urine osmolality, which, however, did not coincide with increased AQP2 abundances. In patients, acetazolamide led to the withdrawal of two patients from the study due to side effects. In the four remaining patients acetazolamide did not lead to clinically relevant changes in maximal urine osmolality. Urine output was also not affected, although none of these patients demonstrated overt lithium-induced polyuria. In three out of four patients, acetazolamide treatment increased serum creatinine levels, indicating a decreased glomerular filtration rate (GFR). Strikingly, these three patients also showed a decrease in systemic blood pressure. All together, our data reveal that acetazolamide does not improve the urinary concentrating defect caused by lithium, but it lowers the GFR, likely explaining the reduced urine output in our mice and in a recently reported patient with lithium-induced polyuria. The reduced GFR in patients prone to chronic kidney disease development, however, warrants against application of acetazolamide in Li-NDI patients without long-term (pre)clinical studies. Copyright © 2017 the American Physiological Society.

  5. Detection of Beta-Emitting Nuclides of Energy >1 Mev in Urine After an Accident by Means of Measurement of the Cerenkov Effect in a Liquid Scintillation Counting System; Detection des Radioelements Emetteurs Beta d'une Energie Superieure a 1 Mev dans l'Urine Apres un Accident, par la Mesure de l'Effet Cerenkov Avec un Ensemble de Comptage a Scintillation Liquide; 041e 0411 041d 0414 ; Deteccion en la Orina de Emisores Beta de Energia Superior a 1 Mev, Despues de un Accidente, por Medicion del Efecto Cerenkov en un Contador de Centelleador Liquido

    Energy Technology Data Exchange (ETDEWEB)

    Narrog, J. [Landesinstitut fuer Arbeitsschutz und Arbeitsmedizin, Karlsruhe, Federal Republic of Germany (Germany)

    1965-06-15

    Beta particles of energy >1 MeV in water can be measured by Cerenkov effect in liquid scintillation counters without any further preparation. Since Hoffman reported about this possibility at the Symposium held by the Gesellschaft Deutscher Chemiker (1-2 April 1964) in Karlsruhe-Leopoldshafen, experiments have been carried out in our institute to apply this method to urine. When experiments were carried out with unprepared urine, the measurements were insensitive because of the strong absorption effect. The urine must be cleared. Therefore we tried to oxidate with KMnO{sub 4} and got a clear liquid. The background was very high, because the K of the KMnO{sub 4} contains the radioactive K{sup 40}, which also emits {beta}-rays of energy > 1 MeV (1.32 MeV). We used Na MnO{sub 4} instead of KMnO{sub 4} and got better results. The background is now about 30 counts/min, the lower limit (measured with Sr{sup 90}/Y{sup 90}) about 1 pc/ml urine. If in accidents the content of radioactive K{sup 40} in urine cannot be assessed (e.g. by flame-photometry of the K-content in urine) this method gives the same sensitivity as other methods (e.g. bum and measure in a large-area proportional counting system), in this case (> 2 pc/ml). The measurement with the large-area proportional counter and additional assessment of the K{sup 40} {beta}-activity of the urine is mere sensitive and more accurate. This method is useful for a rapid measurement of large body burdens (and following excretion) of {beta}-nuclides of energy > 1 MeV, demanded by an accidental situation. With these methods we need no more than 90 min total time. (author) [French] On peut mesurer les particules beta d'une energie superieure a 1 MeV grace a l'effet Cerenkov dans des compteurs a scintillation liquide sans aucune autre preparation. Depuis que Hoffmann en a signale la possibilite a un colloque organise par la Gesellschaft Deutscher Chemiker les 1{sup er} et 2 avril 1964 a Karlsruhe-Leopoldshafen, l'auteur a

  6. Simultaneous differential spinning disk fluorescence optical sectioning microscopy and nanomechanical mapping atomic force microscopy

    International Nuclear Information System (INIS)

    Miranda, Adelaide; De Beule, Pieter A. A.; Martins, Marco

    2015-01-01

    Combined microscopy techniques offer the life science research community a powerful tool to investigate complex biological systems and their interactions. Here, we present a new combined microscopy platform based on fluorescence optical sectioning microscopy through aperture correlation microscopy with a Differential Spinning Disk (DSD) and nanomechanical mapping with an Atomic Force Microscope (AFM). The illumination scheme of the DSD microscope unit, contrary to standard single or multi-point confocal microscopes, provides a time-independent illumination of the AFM cantilever. This enables a distortion-free simultaneous operation of fluorescence optical sectioning microscopy and atomic force microscopy with standard probes. In this context, we discuss sample heating due to AFM cantilever illumination with fluorescence excitation light. Integration of a DSD fluorescence optical sectioning unit with an AFM platform requires mitigation of mechanical noise transfer of the spinning disk. We identify and present two solutions to almost annul this noise in the AFM measurement process. The new combined microscopy platform is applied to the characterization of a DOPC/DOPS (4:1) lipid structures labelled with a lipophilic cationic indocarbocyanine dye deposited on a mica substrate

  7. Simultaneous differential spinning disk fluorescence optical sectioning microscopy and nanomechanical mapping atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Adelaide; De Beule, Pieter A. A., E-mail: pieter.de-beule@inl.int [Applied Nano-Optics Laboratory, International Iberian Nanotechnology Laboratory, Avenida Mestre José Veiga, s/n, 4715-330 Braga (Portugal); Martins, Marco [Nano-ICs Group, International Iberian Nanotechnology Laboratory, Avenida Mestre José Veiga, s/n, 4715-330 Braga (Portugal)

    2015-09-15

    Combined microscopy techniques offer the life science research community a powerful tool to investigate complex biological systems and their interactions. Here, we present a new combined microscopy platform based on fluorescence optical sectioning microscopy through aperture correlation microscopy with a Differential Spinning Disk (DSD) and nanomechanical mapping with an Atomic Force Microscope (AFM). The illumination scheme of the DSD microscope unit, contrary to standard single or multi-point confocal microscopes, provides a time-independent illumination of the AFM cantilever. This enables a distortion-free simultaneous operation of fluorescence optical sectioning microscopy and atomic force microscopy with standard probes. In this context, we discuss sample heating due to AFM cantilever illumination with fluorescence excitation light. Integration of a DSD fluorescence optical sectioning unit with an AFM platform requires mitigation of mechanical noise transfer of the spinning disk. We identify and present two solutions to almost annul this noise in the AFM measurement process. The new combined microscopy platform is applied to the characterization of a DOPC/DOPS (4:1) lipid structures labelled with a lipophilic cationic indocarbocyanine dye deposited on a mica substrate.

  8. Applications of microscopy in Salmonella research.

    Science.gov (United States)

    Malt, Layla M; Perrett, Charlotte A; Humphrey, Suzanne; Jepson, Mark A

    2015-01-01

    Salmonella enterica is a Gram-negative enteropathogen that can cause localized infections, typically resulting in gastroenteritis, or systemic infection, e.g., typhoid fever, in humans and many other animals. Understanding the mechanisms by which Salmonella induces disease has been the focus of intensive research. This has revealed that Salmonella invasion requires dynamic cross-talk between the microbe and host cells, in which bacterial adherence rapidly leads to a complex sequence of cellular responses initiated by proteins translocated into the host cell by a type 3 secretion system. Once these Salmonella-induced responses have resulted in bacterial invasion, proteins translocated by a second type 3 secretion system initiate further modulation of cellular activities to enable survival and replication of the invading pathogen. Elucidation of the complex and highly dynamic pathogen-host interactions ultimately requires analysis at the level of single cells and single infection events. To achieve this goal, researchers have applied a diverse range of microscopy techniques to analyze Salmonella infection in models ranging from whole animal to isolated cells and simple eukaryotic organisms. For example, electron microscopy and high-resolution light microscopy techniques such as confocal microscopy can reveal the precise location of Salmonella and its relationship to cellular components. Widefield light microscopy is a simpler approach with which to study the interaction of bacteria with host cells and often has advantages for live cell imaging, enabling detailed analysis of the dynamics of infection and cellular responses. Here we review the use of imaging techniques in Salmonella research and compare the capabilities of different classes of microscope to address specific types of research question. We also provide protocols and notes on some microscopy techniques used routinely in our own research.

  9. Estimation of D-Arabinose by Gas Chromatography/Mass Spectrometry as Surrogate for Mycobacterial Lipoarabinomannan in Human Urine.

    Directory of Open Access Journals (Sweden)

    Prithwiraj De

    Full Text Available Globally, tuberculosis is slowly declining each year and it is estimated that 37 million lives were saved between 2000 and 2013 through effective diagnosis and treatment. Currently, diagnosis relies on demonstration of the bacteria, Mycobacterium tuberculosis (Mtb, in clinical specimens by serial sputum microscopy, culture and molecular testing. Commercial immunoassay lateral flow kits developed to detect Mtb lipoglycan lipoarabinomannan (LAM in urine as a marker of active TB exhibit poor sensitivity, especially in immunocompetent individuals, perhaps due to low abundance of the analyte. Our present study was designed to develop methods to validate the presence of LAM in a quantitative fashion in human urine samples obtained from culture-confirmed TB patients. Herein we describe, a consolidated approach for isolating LAM from the urine and quantifying D-arabinose as a proxy for LAM, using Gas Chromatography/Mass Spectrometry. 298 urine samples obtained from a repository were rigorously analyzed and shown to contain varying amounts of LAM-equivalent ranging between ~10-40 ng/mL. To further substantiate that D-arabinose detected in the samples originated from LAM, tuberculostearic acid, the unique 10-methyloctadecanoic acid present at the phosphatidylinositol end of LAM was also analyzed in a set of samples and found to be present confirming that the D-arabinose was indeed derived from LAM. Among the 144 samples from culture-negative TB suspects, 30 showed presence of D-arabinose suggesting another source of the analyte, such as disseminated TB or from non-tuberculosis mycobacterium. Our work validates that LAM is present in the urine samples of culture-positive patients in small but readily detectable amounts. The study further substantiates LAM in urine as a powerful biomarker for active tuberculosis.

  10. [Black urine or black sclera of the eyes? Consider alkaptonuria].

    Science.gov (United States)

    Gubbels, Nanda P; Sijbrand, Merijn H; Onstenk, Ron

    2014-01-01

    Alkaptonuria is a rare metabolic disorder due to a defect in the gene for homogentisic acid oxidase. This results in an accumulation of homogentisic acid, which leads to the deposit of pigment in the connective tissue in the body. This causes problems and symptoms in various organ systems, such as early artropathy, dark-coloured urine, black sclerae, dark-coloured aortic valves and an increased risk of kidney stones and gall stones. Various specialists may see patients with this disease. The diagnosis is often missed. We describe a 69-year-old woman who underwent surgery due to joint problems, which showed up black cartilage. It turned out that for many years she had also had eye and heart problems. Not until later in life was she diagnosed with alkaptonuria. There is no curative treatment for alkaptonuria at the moment. Early recognition of the disease can increase the quality of life. Preventative check-ups and guidance are also therefore necessary.

  11. Sample preparation automation for dosing plutonium in urine

    International Nuclear Information System (INIS)

    Jeanmaire, Lucien; Ballada, Jean; Ridelle Berger, Ariane

    1969-06-01

    After having indicated that dosing urinary plutonium by using the Henry technique can be divided into three stages (plutonium concentration by precipitation, passing the solution on an anionic resin column and plutonium elution, and eluate evaporation to obtain a source of which the radioactivity is measured), and recalled that the automation of the second stage has been reported in another document, this document describes the automation of the first stage, i.e. obtaining from urine a residue containing the plutonium, and sufficiently mineralized to be analyzed by means of ion exchanging resins. Two techniques are proposed, leading to slightly different devices. The different operations to be performed are indicated. The different components of the apparatus are described: beakers, hot plate stirrers, reagent circuits, a system for supernatant suction, and a control-command circuit. The operation and use are then described, and results are given

  12. Electron microscopy (nonbiological)

    International Nuclear Information System (INIS)

    Cowley, J.M.

    1986-01-01

    The period 1982-1985, which is covered by this review, has seen major advances in the capabilities of the commercially available instruments. The new electron microscopes operating in the range of 300-400 keV have provided important improvements in the resolution available and in the possibilities for microanalysis of very small specimen areas. Correspondingly there has been a broadening in the range of possible applications of the techniques. Electron microscopy has become a much more powerful tool for studies of semiconductors and catalysts, for example, and offers promise of a major revolution in surface science. The major industrial laboratories, in particular, are investing in million-dollar instruments and in the highly skilled scientists needed to run them because the capabilities of the new instruments are seen to have immediate practical applications to current industrial research. Unfortunately all of the new instruments and most of the skilled users come from overseas. The American instrument industry, although showing some limited signs of life, is not yet in a position to compete in this lucrative market and the training of electron optics specialists in this country is far from meeting the demand. The increased sophistication required for both the operation of the instruments and the interpretation of the observation requires that the quality as well as the quantity of trainees must be improved. 62 references

  13. Superconductivity and electron microscopy

    International Nuclear Information System (INIS)

    Hawkes, P.W.; Valdre, U.

    1977-01-01

    In this review article, two aspects of the role of superconductivity in electron microscopy are examined: (i) the development of superconducting devices (mainly lenses) and their incorporation in electron microscopes; (ii) the development of electron microscope techniques for studying fundamental and technological problems associated with superconductivity. The first part opens with a brief account of the relevant properties of conventional lenses, after which the various types of superconducting lenses are described and their properties compared. The relative merits and inconveniences of superconducting and conventional lenses are examined, particular attention being paid to the spherical and chromatic aberration coefficients at accelerating voltages above a megavolt. This part closes with a survey of the various microscope designs that have been built or proposed, incorporating superconducting components. In the second part, some methods that have been or might be used in the study of superconductivity in the electron microscope are described. A brief account of the types of application for which they are suitable is given. (author)

  14. Innovative Strategies for Clinical Microscopy Instruction: Virtual Versus Light Microscopy.

    Science.gov (United States)

    McDaniel, M Jane; Russell, Gregory B; Crandall, Sonia J

    2018-06-01

    The purpose of the study was to compare virtual microscopy with light microscopy to determine differences in learning outcomes and learner attitudes in teaching clinical microscopy to physician assistant (PA) students. A prospective, randomized, crossover design study was conducted with a convenience sample of 67 first-year PA students randomized to 2 groups. One group used light microscopes to find microscopic structures, whereas the other group used instructor-directed video streaming of microscopic elements. At the midpoint of the study, the groups switched instructional strategies. Learning outcomes were assessed via posttest after each section of the study, with comparison of final practical examination results to previous cohorts. Attitudes about the 2 educational strategies were assessed through a postcourse questionnaire with a Likert scale. Analysis of the first posttest demonstrated that students in the video-streamed group had significantly better learning outcomes than those in the light microscopy group (P = .004; Cohen's d = 0.74). Analysis of the posttest after crossover showed no differences between the 2 groups (P = .48). Between the 2 posttests, students first assigned to the light microscopy group scored a 6.6 mean point increase (±10.4 SD; p = .0011), whereas students first assigned to the virtual microscopy group scored a 1.3 mean point increase (±7.1 SD; p = .29). The light microscopy group improved more than the virtual microscopy group (P = .019). Analysis of practical examination data revealed higher scores for the study group compared with 5 previous cohorts of first-year students (P virtual microscopy to traditional light microscopy. Virtual microscopy is an effective educational strategy, and students prefer this method when learning to interpret images of clinical specimens.

  15. Functional photoacoustic microscopy of pH.

    Science.gov (United States)

    Chatni, Muhammad Rameez; Yao, Junjie; Danielli, Amos; Favazza, Christopher P; Maslov, Konstantin I; Wang, Lihong V

    2011-10-01

    pH is a tightly regulated indicator of metabolic activity. In mammalian systems, an imbalance of pH regulation may result from or result in serious illness. In this paper, we report photoacoustic microscopy (PAM) of a commercially available pH-sensitive fluorescent dye (SNARF-5F carboxylic acid) in tissue phantoms. We demonstrated that PAM is capable of pH imaging in absolute values at tissue depths of up to 2.0 mm, greater than possible with other forms of optical microscopy.

  16. Optically sectioned imaging by oblique plane microscopy

    Science.gov (United States)

    Kumar, Sunil; Lin, Ziduo; Lyon, Alex R.; MacLeod, Ken T.; Dunsby, Chris

    2011-03-01

    Oblique Plane Microscopy (OPM) is a light sheet microscopy technique that combines oblique illumination with correction optics that tilt the focal plane of the collection system. OPM can be used to image conventionally mounted specimens on coverslips or tissue culture dishes and has low out-of-plane photobleaching and phototoxicity. No moving parts are required to achieve an optically sectioned image and so high speed optically sectioned imaging is possible. The first OPM results obtained using a high NA water immersion lens on a commercially available inverted microscope frame are presented, together with a measurement of the achievable optical resolution.

  17. Study in electron microscopy the formation of the hybrid layer using adhesive systems One Coat and Single Bond Universal, at the Facultad de Medicina of the Universidad de Costa Rica

    International Nuclear Information System (INIS)

    Parra Barillas, Adriana; Montoya, Michael

    2013-01-01

    The formation of the hybrid layer is observed in dental pieces in vitro, using systems of conventional adhesives (Single Bond 2 of 3M and One Coat of Coltene), with different times of acid etching, through the use of atomic force microscopy (AFM). The images of the hybrid layer obtained from samples prepared with adhesive systems are analyzed by AFM. Samples collected have been of dental pieces (molars and premolars) recently extracted and later placed in water. The pieces used have provided more surface to be observed under the microscope, greater accessibility to the be cut for its study, and to the great pieces have facilitated their placement on the Isomet low speed saw. The differences are evaluated between hybrid layers according the adhesive system used and the mode of application of the images obtained in the atomic force microscope. The adhesive system that has allowed the formation of a hybrid layer more appropriate between the adhesive system One Coat and the adhesive system Single Bond Universal is determined. The time of acid etching as variable of procedure is determined and has interfered with the formation of a hybrid layer more stable. The images evaluated that were provided by the atomic force microscope and compared with the images of electron microscopy of other studies, have determined that the AFM is without providing detailed information, as well as the appropriate images to evaluate the hybrid layer of the adhesive systems Single Bond 2 and One Coat of Coltene, or the different times of acid etching. Therefore, for this type of study, the image of choice must be of an electron microscope [es

  18. NDE Acoustic Microscopy Research Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The purpose is to develop advanced, more effective high-resolution micro-NDE materials characterization methods using scanning acoustic microscopy. The laboratory's...

  19. Spectroscopy and atomic force microscopy of biomass.

    Science.gov (United States)

    Tetard, L; Passian, A; Farahi, R H; Kalluri, U C; Davison, B H; Thundat, T

    2010-05-01

    Scanning probe microscopy has emerged as a powerful approach to a broader understanding of the molecular architecture of cell walls, which may shed light on the challenge of efficient cellulosic ethanol production. We have obtained preliminary images of both Populus and switchgrass samples using atomic force microscopy (AFM). The results show distinctive features that are shared by switchgrass and Populus. These features may be attributable to the lignocellulosic cell wall composition, as the collected images exhibit the characteristic macromolecular globule structures attributable to the lignocellulosic systems. Using both AFM and a single case of mode synthesizing atomic force microscopy (MSAFM) to characterize Populus, we obtained images that clearly show the cell wall structure. The results are of importance in providing a better understanding of the characteristic features of both mature cells as well as developing plant cells. In addition, we present spectroscopic investigation of the same samples.

  20. Electron microscopy and forensic practice

    Science.gov (United States)

    Kotrlý, Marek; Turková, Ivana

    2013-05-01

    Electron microanalysis in forensic practice ranks among basic applications used in investigation of traces (latents, stains, etc.) from crime scenes. Applying electron microscope allows for rapid screening and receiving initial information for a wide range of traces. SEM with EDS/WDS makes it possible to observe topography surface and morphology samples and examination of chemical components. Physical laboratory of the Institute of Criminalistics Prague use SEM especially for examination of inorganic samples, rarely for biology and other material. Recently, possibilities of electron microscopy have been extended considerably using dual systems with focused ion beam. These systems are applied mainly in study of inner micro and nanoparticles , thin layers (intersecting lines in graphical forensic examinations, analysis of layers of functional glass, etc.), study of alloys microdefects, creating 3D particles and aggregates models, etc. Automated mineralogical analyses are a great asset to analysis of mineral phases, particularly soils, similarly it holds for cathode luminescence, predominantly colour one and precise quantitative measurement of their spectral characteristics. Among latest innovations that are becoming to appear also at ordinary laboratories are TOF - SIMS systems and micro Raman spectroscopy with a resolution comparable to EDS/WDS analysis (capable of achieving similar level as through EDS/WDS analysis).

  1. The use of spinning-disk confocal microscopy for the intravital analysis of platelet dynamics in response to systemic and local inflammation.

    Directory of Open Access Journals (Sweden)

    Craig N Jenne

    Full Text Available Platelets are central players in inflammation and are an important component of the innate immune response. The ability to visualize platelets within the live host is essential to understanding their role in these processes. Past approaches have involved adoptive transfer of labelled platelets, non-specific dyes, or the use of fluorescent antibodies to tag platelets in vivo. Often, these techniques result in either the activation of the platelet, or blockade of specific platelet receptors. In this report, we describe two new methods for intravital visualization of platelet biology, intravenous administration of labelled anti-CD49b, which labels all platelets, and CD41-YFP transgenic mice, in which a percentage of platelets express YFP. Both approaches label endogenous platelets and allow for their visualization using spinning-disk confocal fluorescent microscopy. Following LPS-induced inflammation, we were able to measure a significant increase in both the number and size of platelet aggregates observed within the vasculature of a number of different tissues. Real-time observation of these platelet aggregates reveals them to be large, dynamic structures that are continually expanding and sloughing-off into circulation. Using these techniques, we describe for the first time, platelet recruitment to, and behaviour within numerous tissues of the mouse, both under control conditions and following LPS induced inflammation.

  2. Handheld Fluorescence Microscopy based Flow Analyzer.

    Science.gov (United States)

    Saxena, Manish; Jayakumar, Nitin; Gorthi, Sai Siva

    2016-03-01

    Fluorescence microscopy has the intrinsic advantages of favourable contrast characteristics and high degree of specificity. Consequently, it has been a mainstay in modern biological inquiry and clinical diagnostics. Despite its reliable nature, fluorescence based clinical microscopy and diagnostics is a manual, labour intensive and time consuming procedure. The article outlines a cost-effective, high throughput alternative to conventional fluorescence imaging techniques. With system level integration of custom-designed microfluidics and optics, we demonstrate fluorescence microscopy based imaging flow analyzer. Using this system we have imaged more than 2900 FITC labeled fluorescent beads per minute. This demonstrates high-throughput characteristics of our flow analyzer in comparison to conventional fluorescence microscopy. The issue of motion blur at high flow rates limits the achievable throughput in image based flow analyzers. Here we address the issue by computationally deblurring the images and show that this restores the morphological features otherwise affected by motion blur. By further optimizing concentration of the sample solution and flow speeds, along with imaging multiple channels simultaneously, the system is capable of providing throughput of about 480 beads per second.

  3. Radio-toxicological analysis of urine

    International Nuclear Information System (INIS)

    Jeanmaire, L.; Jammet, H.

    1959-01-01

    The article is divided into two parts: general and technical. In the general part, a study of the behaviour of radioisotopes in the organism shows the hazards of internal contamination. In addition, the principle of the different methods for the estimation of this contamination is indicated. The second part, which is purely technical, describes some of the methods for urine analysis used in the S.H.A.R.P. radiotoxicology laboratory at the Saclay Nuclear Research Centre. The techniques relate to 239 Pu, 226 Ra, 90 Sr, natural Th, natural U and 233 U. Reprint of a paper published in Annales de Radiologie, Vol. 2, no. 9-10, p. 703-722, 1959 [fr

  4. Taking the Piss : Urine in Early Modern Europe

    NARCIS (Netherlands)

    Verwaal, Ruben

    2017-01-01

    As long as there have been humans, urine has been regularly discharged. You may not consider your urine very interesting. In fact, you may be very eager to leave your messy and leaky excretion behind in the bathroom. But have we always looked at this fluid with a feeling of disgust? What did people

  5. Domestic Cat (Felis silvestris catus) Urine Odour as a Potential ...

    African Journals Online (AJOL)

    The aim of this study was to investigate the effects of cat urine odour extract on rodent pest species to reduce crop losses. Cat urine from the captured cats was drawn using cat catcher. Urinary catheter was inserted into the urethra up to the urinary bladder and a syringe attached to the urinary catheter was used to draw ...

  6. Exorphin Peptides in Urine with HPLC-MS/MS Detection

    OpenAIRE

    2015-01-01

    Exorphins have been found in urine from individuals diagnosed with autism spectrum disorders by HPLC techniques. However, several studies, using sophisticated analytical techniques , have reported negative findings. This made it necessary to improve our methods. The sample stability during transport and storage and the pre -analytical treatment of urines was improved by peptidase inhibition and solid ...

  7. Analyte variations in consecutive 24-hour urine collections in children.

    Science.gov (United States)

    Ellison, Jonathan S; Hollingsworth, John M; Langman, Craig B; Asplin, John R; Schwaderer, Andrew L; Yan, Phyllis; Bierlein, Maggie; Barraza, Mark A; Defoor, William R; Figueroa, T Ernesto; Jackson, Elizabeth C; Jayanthi, Venkata R; Johnson, Emilie K; Joseph, David B; Shnorhavorian, Margarett

    2017-12-01

    The metabolic evaluation of children with nephrolithiasis begins with a 24-h urine collection. For adults, the diagnostic yield increases with consecutive collections; however, little is known regarding the variability of multiple 24-h studies in the pediatric population. We sought to evaluate the variability of consecutive 24-h urine collection in children through a multi-institutional study hypothesizing that compared with a single collection, consecutive 24-h urine collections would reveal a greater degree of clinically useful information in the evaluation of children at risk for nephrolithiasis. Including data from six institutions, we identified children less than 18 years of age considered at risk for recurrent nephrolithiasis, undergoing metabolic evaluation. We evaluated a subset of patients performing two collections with urine creatinine varying by 10% or less during a 7-day period. Discordance between repeat collections based on normative urine chemistry values was evaluated. A total of 733 children met inclusion criteria, and in over a third both urine calcium and urine volume differed by 30% or more between samples. Urine oxalate demonstrated greater variation between collections in children collections prior to targeted intervention to modify stone risk are advised to increase diagnostic yield in children at risk for nephrolithiasis. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  8. Antibiotics susceptibility patterns of urine bacterial isolates in Zaria ...

    African Journals Online (AJOL)

    Purpose: The prevalence of E. coli, Ps. aeruginosa and Staph aureus isolates from urine of selected residents in Zaria was investigated. This was an attempt to elucidate the antibiotic susceptibility profiles of these bacteria commonly implicated in urinary tact infection. Methods: Urine samples collected from students of ...

  9. Acute and chronic urine retention among adults at the urology ...

    African Journals Online (AJOL)

    E.M.T. Yenli

    A complete work-up to establish the cause of urine ... acute or chronic urine retention was caused mainly by bladder cancer and neurogenic bladder. Initial and ... associated with a significantly impaired quality of life, stigmatiza- tion and a ..... to ensure that they remained healthy and did not have any infection connected with ...

  10. effects of artemether on the plasma and urine concentrations of ...

    African Journals Online (AJOL)

    Dr Komolafe

    2011-05-16

    May 16, 2011 ... degeneration of the renal tissue of rats, inability of the damaged kidneys to concentrate urine, which manifested as excessive water loss and electrolyte depletion. Key words: Artemether, electrolytes in plasma, urine concentrations, rats. INTRODUCTION. Artemether, one of the derivatives of artemisinin, is.

  11. Value of urine cytology in screening patients with prostatitis syndromes

    NARCIS (Netherlands)

    de la Rosette, J. J.; Hubregtse, M. R.; Wiersma, A. M.; Debruyne, F. M.

    1993-01-01

    We reviewed the results of urine cytology examination of 206 patients with a diagnosis of prostatitis syndromes in the period 1985-1991. The urine samples showed an incidence of 20.4% for slight to moderate atypia and 6.3% for severe atypia. In these patients, cystoscopy, bladder biopsies and

  12. Fertilizer value of urine in pumpkin (Cucurbita maxima L. cultivation

    Directory of Open Access Journals (Sweden)

    S.K. PRADHAN

    2008-12-01

    Full Text Available The fertilizer value of human urine was compared with mineral fertilizer in pumpkin (Cucurbita maxima cultivation at a dose of 113 kg N ha-1 with no-fertilization used as control. The growth of the vine was better in urine fertilized pumpkins than in mineral fertilized and non-fertilized pumpkins. Total fruit biomass was higher in mineral fertilized plants compared to urine fertilized and non-fertilized pumpkins. Urine fertilized pumpkins may have suffered from lower potassium or higher chloride, thus they produced fewer flowers and fruits. However, total fruit biomass and the number of fruits were slightly higher in urine fertilized plants than in their non-fertilized counterparts, i.e. 17.2 t ha-1 more pumpkin could be produced with urine fertilizer. The microbial hygiene quality as well as the contents of soluble sugars, protein and taste quality were similar in all treatments, but lower nitrate and higher chloride contents were recorded in urine fertilized pumpkins than other treatments. In conclusion, our study shows that the production rate of urine fertilized pumpkins was somewhat lower than mineral fertilized pumpkins but it was higher than non-fertilized pumpkins. The hygienic quality was equally good with all treatments.;

  13. Effectiveness of the Domestic Cat (Felis silvestris catus) Urine ...

    African Journals Online (AJOL)

    The stored cat urine was then thawed and mixed with maize starch to form a thick dough and then granulated and dried at room temperature before being packed in a hermetically closed jar. Initially, rodent foot marks on tracking soot coat tiles were used to estimate the rat population before the cat urine extracts application.

  14. The importance of cooling of urine samples for doping analysis

    NARCIS (Netherlands)

    Kuenen, J. Gijs; Konings, Wil N.

    Storing and transporting of urine samples for doping analysis, as performed by the anti-doping organizations associated with the World Anti-Doping Agency, does not include a specific protocol for cooled transport from the place of urine sampling to the doping laboratory, although low cost cooling

  15. Effects of diet composition on mutagenic activity in urine.

    Science.gov (United States)

    Ohara, Akihiro; Matsuhisa, Tsugio

    2004-01-01

    The effects of dietary habits on mutagenic activity in urine were investigated using the umu test based on the use of the genetically engineered bacteria Salmonella typhimurium TA 1535 pSK1002. Genotoxic effects in sample urine were detected by measuring the activation of the SOS response in the bacteria and recording the beta- galactosidase activity. Human subjects consisted of smokers and non-smokers. Urine from subjects who consumed fish showed the highest mutagenic activity, followed by the urine samples from subjects who ate pork or beef. Chicken induced a low level of mutagenic activity. When the subjects ate fried or roasted animal foods, the urine samples gave higher mutagenicity than the urine samples from the subject who consumed non-fried or non-roasted animal foods. When the subject ate vegetables along with a diet rich in animal foods, the activity in urine decreased. Herbs and spices gave the same tendency toward decline as vegetables. Non-smoker urine shower mutagenic activity than samples from smokers.

  16. SPE-NMR metabolite sub-profiling of urine

    NARCIS (Netherlands)

    Jacobs, D.M.; Spiesser, L.; Garnier, M.; Roo, de N.; Dorsten, van F.; Hollebrands, B.; Velzen, van E.; Draijer, R.; Duynhoven, van J.P.M.

    2012-01-01

    NMR-based metabolite profiling of urine is a fast and reproducible method for detection of numerous metabolites with diverse chemical properties. However, signal overlap in the (1)H NMR profiles of human urine may hamper quantification and identification of metabolites. Therefore, a new method has

  17. Polyglycolic acid (Dexon) sutures in Escherichia coli infected urine

    DEFF Research Database (Denmark)

    Hovendal, C P; Schwartz, W

    1979-01-01

    The tensile strength, knot strength and stretch of polyglycolic acid (Dexon) was studied after emersion in physiological saline, sterile urine and infected urine. Tests were made each day under controlled conditions over a 10 day period. The results are compared with those of other earlier studie...

  18. Effect Of Instructions About The Method Of Urine Collection And ...

    African Journals Online (AJOL)

    Despite the explanation, 15(23.1%) of the patients collected the urine samples wrongly and 44(67.7%) stored the samples for longer than one hour. Significant bacteriuria was more prevalent in 74.2% of patients who submitted their urine samples more than one hour after collection. Communication skill is important and ...

  19. Determination of natural thorium in urines; Dosage du thorium dans les urines

    Energy Technology Data Exchange (ETDEWEB)

    Jeanmaire, L; Jammet, H [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    A procedure for the quantitative analysis of thorium in urine is described. After precipitation with ammonium hydroxide, dissolution of the precipitate, extraction at pH 4-4.2 with cupferron in chloroformic solution and mineralization, a colorimetric determination of thorium with thorin is performed. It is thus possible to detect about 2 {gamma} of thorium in the sample. (author) [French] Cet article decrit une technique de dosage du thorium dans l'urine. Apres precipitation par l'ammoniaque, remise en solution, extraction a pH 4-4,2 par le cupferron en solution chloroformique et mineralisation, le thorium est dose par colorimetrie avec le thorin. Cette methode permet de deceler environ 2 {gamma} de thorium dans l'echantillon. (auteur)

  20. Natural radionuclides in urine- and faeces samples; Natuerliche Radionuklide in Urin- und Stuhlproben

    Energy Technology Data Exchange (ETDEWEB)

    Froning, M.; Burow, M.; Ennen, R.; Hoelters, A.; Laumen-Sentis, S.; Zoriy, M. [Forschungszentrum Juelich GmbH (Germany). Geschaeftsbereich Sicherheit und Strahlenschutz

    2016-07-01

    In interpreting of measurement data for incorporation monitoring by excretion samples a clear distinction between the natural intake and the fraction subjected due to occupational exposure should be performed. At the present only a few data about an excretion of primordial elements such as {sup 238}U, {sup 232}Th are available in the literature. In the following study actual data measured in urine and faeces will be presented and discussed.

  1. Electronic Blending in Virtual Microscopy

    Science.gov (United States)

    Maybury, Terrence S.; Farah, Camile S.

    2010-01-01

    Virtual microscopy (VM) is a relatively new technology that transforms the computer into a microscope. In essence, VM allows for the scanning and transfer of glass slides from light microscopy technology to the digital environment of the computer. This transition is also a function of the change from print knowledge to electronic knowledge, or as…

  2. Assessment of tissue fibrosis in skin biopsies from patients with systemic sclerosis employing confocal laser scanning microscopy: an objective outcome measure for clinical trials?

    Science.gov (United States)

    Busquets, Joanna; Del Galdo, Francesco; Kissin, Eugene Y.

    2010-01-01

    Objectives. To obtain an objective, unbiased assessment of skin fibrosis in patients with SSc for use in clinical trials of SSc disease-modifying therapeutics. Methods. Skin biopsies from the dorsal forearm of six patients with diffuse SSc and six healthy controls, and skin biopsies from the forearm of one patient with diffuse SSc before and following 1 year treatment with mycophenolate mofetil were analysed by confocal laser scanning microscopy (CLSM) with specific antibodies against collagen types I and III or fibronectin. The integrated density of fluorescence (IDF) was calculated employing National Institutes of Health-ImageJ software in at least four different fields per biopsy spanning the full dermal thickness. Results. The intensities of collagen types I and III and fibronectin IDF were 174, 147 and 139% higher in SSc skin than in normal skin, respectively. All differences were statistically significant. The sum of the IDF values obtained for the three proteins yielded a comprehensive fibrosis score. The average fibrosis score for the six SSc samples was 28.3 × 106 compared with 18.6 × 106 for the six normal skin samples (P < 0.0001). Comparison of skin biopsies obtained from the same SSc patient before treatment and after 12 months of treatment with mycophenolate mofetil showed a reduction of 39% in total fibrosis score after treatment. Conclusions. CLSM followed by quantitative image analysis provides an objective and unbiased assessment of skin fibrosis in SSc and could be a useful end-point for clinical trials with disease-modifying agents to monitor the response or progression of the disease. PMID:20202926

  3. A new approach for the detection of charged particles by photographic recording systems - first applications in corpuscular physics, biology and electron microscopy

    International Nuclear Information System (INIS)

    Rechenmann, R.V.; Wittendorp, E.; Senger, B.

    1977-01-01

    The activation procedure consists not only of the introduction of more or less sophisticated treatments in the development phase, but also of the setting up of a specific ionographic methodology which will be described. The working hypotheses which led to the formulation of the so-called activation treatments will be outlined, notably the concept of the stable sub-latent image. The consequences of the activation procedure in ionography will be recalled, e.g. the drastic increase of the signal/noise ratio ranging from 1.5 to 20 and more, as well as the remarkable stability of the fog. The interest of the activation procedure for corpuscular physics as well as for the life sciences will be illustrated by first applications in autoradiography, electron microscopy and microdosimetry. As far as the autoradiographic methods are concerned, the considerable increase in efficiency and in resolution results in a drastic decrease of the exposure time or/and of the quantity of tracer elements applied, as well as in the possibility to carry out studies implying the detection of very small amounts of activity. The activation of the latent image can also be applied to exposed electron microscope photographic plates in order to allow a non-destructive observation of very sensitive specimens (macromolecules, etc.). In the field of corpuscular physics, the activation treatments led to the detection of secondary events distributed along α tracks of medium and low energy recorded in nuclear emulsions. An analytical study confirmed the hypotheses that the largest part of these protuberances are tracks of electrons and H-nuclei ejected by the incoming particle. These investigations are intended to lead to a description of the ionizing track pattern as well as to the interpretation of experimentally determined fluctuations of the track width. (author)

  4. Analysis system of submicron particle tracks in the fine-grained nuclear emulsion by a combination of hard x-ray and optical microscopy

    International Nuclear Information System (INIS)

    Naka, T.; Asada, T.; Yoshimoto, M.; Katsuragawa, T.; Tawara, Y.; Umemoto, A.; Suzuki, Y.; Terada, Y.; Takeuchi, A.; Uesugi, K.; Kimura, M.

    2015-01-01

    Analyses of nuclear emulsion detectors that can detect and identify charged particles or radiation as tracks have typically utilized optical microscope systems because the targets have lengths from several μm to more than 1000 μm. For recent new nuclear emulsion detectors that can detect tracks of submicron length or less, the current readout systems are insufficient due to their poor resolution. In this study, we developed a new system and method using an optical microscope system for rough candidate selection and the hard X-ray microscope system at SPring-8 for high-precision analysis with a resolution of better than 70 nm resolution. Furthermore, we demonstrated the analysis of submicron-length tracks with a matching efficiency of more than 99% and position accuracy of better than 5 μm. This system is now running semi-automatically

  5. Urine Creatinine Concentrations in Drug Monitoring Participants and Hospitalized Patients.

    Science.gov (United States)

    Love, Sara A; Seegmiller, Jesse C; Kloss, Julie; Apple, Fred S

    2016-10-01

    Urine drug testing is commonly performed in both clinical and forensic arenas for screening, monitoring and compliance purposes. We sought to determine if urine creatinine concentrations in monitoring program participants were significantly different from hospital in-patients and out-patients undergoing urine drug testing. We retrospectively reviewed urine creatinine submitted in June through December 2015 for all specimens undergoing urine drug testing. The 20,479 creatinine results were categorized as hospitalized patients (H) and monitoring/compliance groups for pain management (P), legal (L) or recovery (R). Median creatinine concentrations (interquartile range, mg/dL) were significantly different (P creatinine concentrations were significantly lower in the R vs. L group (Pcreatinine concentration and may indicate participants' attempts to tamper with their drug test results through dilution means. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Bioassay techniques for {sup 55}Fe in urine samples

    Energy Technology Data Exchange (ETDEWEB)

    Cregan, S P; Leon, J W; Linauskas, S H

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for {sup 55}Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH){sub 3}. precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs.

  7. Bioassay techniques for 55Fe in urine samples

    International Nuclear Information System (INIS)

    Cregan, S.P.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    Solvent extraction, ion chromatography and several rapid screening methods were developed and evaluated for 55 Fe bioassay applications. Isopropyl ether and TNOA column extractions had radiochemical recoveries exceeding 90%. These were very reproducible with a coefficient of variation less than 5%. Screening techniques investigated included direct counting of ashed urine solids, and Fe(OH) 3 . precipitated from urine. The sensitivities (2-50 Bq/d urine) of the screening methods were usually limited by the effective urine volume that could be counted in a liquid scintillation counter. The reference isopropyl ether and chromatography methods could easily achieve sensitivities well below the 1 Bq/d urine output target. (author). 49 refs., 3 tabs., 5 figs

  8. Analysis of Urine as Indicators of Specific Body Conditions

    Science.gov (United States)

    Dey, Souradeep; Saha, Triya; Narendrakumar, Uttamchand

    2017-11-01

    Urinalysis can be defined as a procedure for examining various factors of urine, which include physical properties, particulate matter, cells, casts, crystals, organisms and solutes. Urinalysis is recommended to be a part of the initial examination of all patients as its cheap, feasible and gives productive results. This paper focuses on the analysis of urine collected at specific body conditions. Here we illustrate the urine profile of different persons having various body conditions, which include, having urinary tract infection, undergoing strenuous exercise, having back pain regularly, having very low urine output and a person who is on 24 hours of diet. Examination of urine collected from different persons having specific body conditions usually helps us in the diagnosis of various diseases, which it indicates.

  9. Urine nickel concentrations in nickel-exposed workers.

    Science.gov (United States)

    Bernacki, E J; Parsons, G E; Roy, B R; Mikac-Devic, M; Kennedy, C D; Sunderman, F W

    1978-01-01

    Electrothermal atomic absorption spectrometry was employed for analyses of nickel concentrations in urine samples from nickel-exposed workers in 10 occupational groups and from non-exposed workers in two control groups. Mean concentrations of nickel in urine were greatest in workers who were exposed to inhalation of aerosols of soluble nickel salts (e.g., workers in nickel plating operations and in an electrolytic nickel refinery). Less marked increases in urine nickel concentrations were found in groups of metal sprayers, nickel battery workers, bench mechanics and are welders. No significant increases in mean concentrations of nickel were found in urine samples from workers who performed grinding, buffing and polishing of nickel-containing alloys or workers in a coal gasification plant who employed Raney nickel as a hydrogenation catalyst. Measurements of nickel concentrations in urine are more sensitive and practical than measurements of serum nickel concentrations for evaluation of nickel exposures in industrial workers.

  10. A simple method for estimation of phosphorous in urine

    International Nuclear Information System (INIS)

    Chaudhary, Seema; Gondane, Sonali; Sawant, Pramilla D.; Rao, D.D.

    2016-01-01

    Following internal contamination of 32 P, it is preferentially eliminated from the body in urine. It is estimated by in-situ precipitation of ammonium molybdo-phosphate (AMP) in urine followed by gross beta counting. The amount of AMP formed in-situ depends on the amount of stable phosphorous (P) present in the urine and hence, it was essential to generate information regarding urinary excretion of stable P. If amount of P excreted is significant then the amount of AMP formed would correspondingly increase leading to absorption of some of the β particles. The present study was taken up for the estimation of daily urinary excretion of P using the phospho-molybdate spectrophotometry method. Few urine samples received from radiation workers were analyzed and based on the observed range of stable P in urine; volume of sample required for 32 P estimation was finalized

  11. Tritium analysis of urine samples from the general Korean public.

    Science.gov (United States)

    Yoon, Seokwon; Ha, Wi-Ho; Lee, Seung-Sook

    2013-11-01

    The tritium concentrations of urine samples and the effective dose of the general Korean public were evaluated. To achieve accurate HTO analysis of urine samples, we established the optimal conditions for measuring the HTO content of urine samples. Urine samples from 50 Koreans who do not work at a nuclear facility were analyzed on the basis of the results. The average urine analysis result was 2.8 ±1 .4 Bq/L, and the range was 1.8-5.6 Bq/L. The measured values were lower than those reported for other countries. These results show that environmental factors and lifestyle differences are the main factors affecting the tritium level of the general public. © 2013 Elsevier Ltd. All rights reserved.

  12. Advanced Microscopy Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides a facility for high-resolution studies of complex biomolecular systems. The goal is an understanding of how to engineer biomolecules for various...

  13. Lack of cross-reactivity of Ambien (zolpidem) with drugs in standard urine drug screens.

    Science.gov (United States)

    Piergies, A A; Sainati, S; Roth-Schechter, B

    1997-04-01

    To determine in healthy volunteers (men and women; 18 to 40 years old) the potential cross-reactivity of Ambien (zolpidem) and/or its metabolites with drugs that are screened by the Syva EMIT II and the Abbott ADx urine drug screens assays. Open-label, fixed-treatment sequence of 1 night each of treatment with zolpidem (10 mg) and temazepam (15 mg). Clinical Pharmacology Unit within a teaching hospital. Over a 24-hour period, presence or absence of positive results on the Syva EMIT II or the Abbott ADx urine drug assay system, each performed at two different laboratory assay sites. Following ingestion of zolpidem, no subject had any positive response in either laboratory to the Syva EMIT II or the Abbott ADx urine drug screen assays at 0, 4, 8, 12, and 24 hours postdose. During the same time period, all subjects had measurable zolpidem plasma concentrations at 1.5 and 8 hours postdose, with mean concentrations of 115.2 ng/mL and 30.1 ng/mL, respectively (in agreement with its half-life of 2.5 hours). The positive response rate at 10 hours after ingestion of Restoril (temazepam) among the four laboratory/assay combinations ranged from 36.8% to 73.7%, a range that is within the reported response rates for these tests. These data indicate that zolpidem will not cross-react in standard urine drug screens with benzodiazepines, opiates, barbiturates, cocaine, cannabinoids, or amphetamines.

  14. Simple Quantification of Pentosidine in Human Urine and Plasma by High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ji Sang Lee

    2017-01-01

    Full Text Available Pentosidine is an advanced glycation end-product (AGE and fluorescent cross-link compound. A simple high-performance liquid chromatographic (HPLC method was developed for the detection and quantification of pentosidine in human urine and plasma. The mobile phase used a gradient system to improve separation of pentosidine from endogenous peaks, and chromatograms were monitored by fluorescent detector set at excitation and emission wavelengths of 328 and 378 nm, respectively. The retention time for pentosidine was 24.3 min and the lower limits of quantification (LLOQ in human urine and plasma were 1 nM. The intraday assay precisions (coefficients of variation were generally low and found to be in the range of 5.19–7.49% and 4.96–8.78% for human urine and plasma, respectively. The corresponding values of the interday assay precisions were 9.45% and 4.27%. Accuracies (relative errors ranged from 87.9% to 115%. Pentosidine was stable in a range of pH solutions, human urine, and plasma. In summary, this HPLC method can be applied in future preclinical and clinical evaluation of pentosidine in the diabetic patients.

  15. Subsurface cadmium loss from a stony soil-effect of cow urine application.

    Science.gov (United States)

    Gray, Colin William; Chrystal, Jane Marie; Monaghan, Ross Martin; Cavanagh, Jo-Anne

    2017-05-01

    Cadmium (Cd) losses in subsurface flow from stony soils that have received cow urine are potentially important, but poorly understood. This study investigated Cd loss from a soil under a winter dairy-grazed forage crop that was grazed either conventionally (24 h) or with restricted grazing (6 h). This provided an opportunity to test the hypothesis that urine inputs could increase Cd concentrations in drainage. It was thought this would be a result of cow urine either (i) enhancing dissolved organic carbon (DOC) concentrations via an increase in soil pH, resulting in the formation of soluble Cd-organic carbon complexes and, or (ii) greater inputs of chloride (Cl) via cow urine, promoting the formation of soluble Cd-Cl complexes. Cadmium concentrations in subsurface flow were generally low, with a spike above the water quality guidelines for a month after the 24-h grazing. Cadmium fluxes were on average 0.30 g Cd ha -1  year -1 (0.27-0.32 g Cd ha -1  year -1 ), in line with previous estimates for agricultural soils. The mean Cd concentration in drainage from the 24-h grazed plots was significantly higher (P soil. Further study is warranted to confirm the mechanisms involved and quantities of Cd lost from other systems.

  16. Determination of uranium in urine: Comparison of ICP-mass spectrometry and delayed neutron assay

    International Nuclear Information System (INIS)

    Gladney, E.S.; Moss, W.D.; Gautier, M.A.; Bell, M.G.

    1986-01-01

    Los Alamos analytical chemistry group acquired a VG-Plasmaquad ICP-MS in January, 1986 and have applied the technique to a variety of environmental and bioassay analytical problems. The authors report on their experience with the determination of uranium and its isotopics in urine and compare this new method with their current uranium procedure, delayed neutron activation analysis (DNA) at the Los Alamos Omega West Reactor. The authors have utilized DNA for bioassay samples since 1978. They currently analyze approximately 2000 urine samples annually. Quantitative data on uranium concentrations are obtained by concurrent measurement of urine standards of known uranium content and isotopic ratio. Detection of 0.03 μg of normal U in a 25 mL sample (1 μg/L) can be achieved by the DNA system. The NRC has proposed new urine bioassay standards that might require at least an order of magnitude reduction in the authors current DNA detection limits. The authors have fully optimized the reactor, and can forsee no instrumental improvement. They may be forced to resort to time-consuming chemical separations at greatly increased costs. DNA is a mature technology with little prospect for radical change. ICPMS is still in its infancy, and there are several ideas for obtaining drastic improvements in detection limits. Costs and time per analysis for both methods are equal

  17. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Dietz, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Kaminski, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Mertz, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Shkrob, I. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial, extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.

  18. A new detector system for low energy X-ray fluorescence coupled with soft X-ray microscopy: First tests and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gianoncelli, Alessandra, E-mail: alessandra.gianoncelli@elettra.eu [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bufon, Jernej [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Ahangarianabhari, Mahdi [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Altissimo, Matteo [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Bellutti, Pierluigi [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Bertuccio, Giuseppe [Politecnico di Milano, Via Anzani 42, Como 22100 (Italy); INFN Milano, Via Celoria 16, Milano 20133 (Italy); Borghes, Roberto [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Carrato, Sergio [University of Trieste, Piazzale Europa 1, Trieste 34127 (Italy); Cautero, Giuseppe [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Fabiani, Sergio [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Giacomini, Gabriele [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Giuressi, Dario [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Kourousias, George [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); Menk, Ralf Hendrik [Elettra-Sincrotrone Trieste S.C.p.A., Strada Statale SS14, km 163.5, Basovizza 34149 (Italy); INFN Trieste, Padriciano 99, Trieste 34149 (Italy); Picciotto, Antonino; Piemonte, Claudio [Fondazione Bruno Kessler, Via Sommarive 18, Trento 38123 (Italy); Rachevski, Alexandre [INFN Trieste, Padriciano 99, Trieste 34149 (Italy); and others

    2016-04-21

    The last decades have witnessed substantial efforts in the development of several detector technologies for X-ray fluorescence (XRF) applications. In spite of the increasing trend towards performing, cost-effective and reliable XRF systems, detectors for soft X-ray spectroscopy still remain a challenge, requiring further study, engineering and customization in order to yield effective and efficient systems. In this paper we report on the development, first characterization and tests of a novel multielement detector system based on low leakage current silicon drift detectors (SDD) coupled to ultra low noise custom CMOS preamplifiers for synchrotron-based low energy XRF. This new system exhibits the potential for improving the count rate by at least an order of magnitude resulting in ten-fold shorter dwell time at an energy resolution similar to that of single element silicon drift detectors.

  19. Microscopy techniques in flavivirus research.

    Science.gov (United States)

    Chong, Mun Keat; Chua, Anthony Jin Shun; Tan, Terence Tze Tong; Tan, Suat Hoon; Ng, Mah Lee

    2014-04-01

    The Flavivirus genus is composed of many medically important viruses that cause high morbidity and mortality, which include Dengue and West Nile viruses. Various molecular and biochemical techniques have been developed in the endeavour to study flaviviruses. However, microscopy techniques still have irreplaceable roles in the identification of novel virus pathogens and characterization of morphological changes in virus-infected cells. Fluorescence microscopy contributes greatly in understanding the fundamental viral protein localizations and virus-host protein interactions during infection. Electron microscopy remains the gold standard for visualizing ultra-structural features of virus particles and infected cells. New imaging techniques and combinatory applications are continuously being developed to push the limit of resolution and extract more quantitative data. Currently, correlative live cell imaging and high resolution three-dimensional imaging have already been achieved through the tandem use of optical and electron microscopy in analyzing biological specimens. Microscopy techniques are also used to measure protein binding affinities and determine the mobility pattern of proteins in cells. This chapter will consolidate on the applications of various well-established microscopy techniques in flavivirus research, and discuss how recently developed microscopy techniques can potentially help advance our understanding in these membrane viruses. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Advantage of multiple spot urine collections for estimating daily sodium excretion: comparison with two 24-h urine collections as reference.

    Science.gov (United States)

    Uechi, Ken; Asakura, Keiko; Ri, Yui; Masayasu, Shizuko; Sasaki, Satoshi

    2016-02-01

    Several estimation methods for 24-h sodium excretion using spot urine sample have been reported, but accurate estimation at the individual level remains difficult. We aimed to clarify the most accurate method of estimating 24-h sodium excretion with different numbers of available spot urine samples. A total of 370 participants from throughout Japan collected multiple 24-h urine and spot urine samples independently. Participants were allocated randomly into a development and a validation dataset. Two estimation methods were established in the development dataset using the two 24-h sodium excretion samples as reference: the 'simple mean method' estimated by multiplying the sodium-creatinine ratio by predicted 24-h creatinine excretion, whereas the 'regression method' employed linear regression analysis. The accuracy of the two methods was examined by comparing the estimated means and concordance correlation coefficients (CCC) in the validation dataset. Mean sodium excretion by the simple mean method with three spot urine samples was closest to that by 24-h collection (difference: -1.62  mmol/day). CCC with the simple mean method increased with an increased number of spot urine samples at 0.20, 0.31, and 0.42 using one, two, and three samples, respectively. This method with three spot urine samples yielded higher CCC than the regression method (0.40). When only one spot urine sample was available for each study participant, CCC was higher with the regression method (0.36). The simple mean method with three spot urine samples yielded the most accurate estimates of sodium excretion. When only one spot urine sample was available, the regression method was preferable.

  1. Deep Learning Microscopy

    KAUST Repository

    Rivenson, Yair; Gorocs, Zoltan; Gunaydin, Harun; Zhang, Yibo; Wang, Hongda; Ozcan, Aydogan

    2017-01-01

    regular optical microscope, without any changes to its design. We blindly tested this deep learning approach using various tissue samples that are imaged with low-resolution and wide-field systems, where the network rapidly outputs an image with remarkably

  2. Ion Acoustic Microscopy

    Science.gov (United States)

    1985-07-01

    Thermal and Related Sciences, L’ Esterel, Quebec (1985), to be published in Can. J. Phys.; H. I. Ringermacher and L. Jackman , "Deep Thermoacoustic Imaging...Research System Bldg. 860 Vandenburg AFB, CA 93437 Dr. Robert V. Ieth, Chief Scientist Div. 76 Hughes Aircraft P.O. Box 902 El Segundo, CA 90245 Dr. Thomas

  3. Urine Galactomannan-to-Creatinine Ratio for Detection of Invasive Aspergillosis in Patients with Hematological Malignancies

    OpenAIRE

    Reischies, Frederike M. J.; Raggam, Reinhard B.; Prattes, Juergen; Krause, Robert; Eigl, Susanne; List, Agnes; Quehenberger, Franz; Strenger, Volker; Wölfler, Albert; Hoenigl, Martin

    2016-01-01

    Galactomannan (GM) testing of urine specimens may provide important advantages, compared to serum testing, such as easy noninvasive sample collection. We evaluated a total of 632 serial urine samples from 71 patients with underlying hematological malignancies and found that the urine GM/creatinine ratio, i.e., (urine GM level × 100)/urine creatinine level, which takes urine dilution into account, reliably detected invasive aspergillosis and may be a promising diagnostic tool for patients with...

  4. Urine leak in minimally invasive partial nephrectomy: analysis of risk factors and role of intraoperative ureteral catheterization

    Directory of Open Access Journals (Sweden)

    Homayoun Zargar

    2014-12-01

    Full Text Available Purpose To investigate risk factors for urine leak in patients undergoing minimally invasive partial nephrectomy (MIPN and to determine the role of intraoperative ureteral catheterization in preventing this postoperative complication. Materials and Methods MIPN procedures done from September 1999 to July 2012 at our Center were reviewed from our IRB-approved database. Patient and tumor characteristics, operative techniques and outcomes were analyzed. Patients with evidence of urine leak were identified. Outcomes were compared between patients with preoperative ureteral catheterization (C-group and those without (NC-group. Univariable and multivariable analyses were performed to identify factors predicting postoperative urine leak. Results A total of 1,019 cases were included (452 robotic partial nephrectomy cases and 567 laparoscopic partial nephrectomy cases. Five hundred twenty eight patients (51.8% were in the C-group, whereas 491 of them (48.2% in the NC-group. Urine leak occurred in 31(3% cases, 4.6% in the C-group and 1.4% in the NC-group (p<0.001. Tumors in NC-group had significantly higher RENAL score, shorter operative and warm ischemic times. On multivariable analysis, tumor proximity to collecting system (OR=9.2; p<0.01, surgeon’s early operative experience (OR=7.8; p<0.01 and preoperative moderate to severe CKD (OR=3.1; p<0.01 significantly increased the odds of the occurrence of a postoperative urine leak. Conclusion Clinically significant urine leak after MIPN in a high volume institution setting is uncommon. This event is more likely to occur in cases of renal masses that are close to the collecting system, in patients with preoperative CKD and when operating surgeon is still in the learning curve for the procedure. Our findings suggest that routine intraoperative ureteral catheterization during MIPN does not reduce the probability of postoperative urine leak. In addition, it adds to the overall operative time.

  5. Estimate of dietary phosphorus intake using 24-h urine collection

    Science.gov (United States)

    Morimoto, Yuuka; Sakuma, Masae; Ohta, Hiroyuki; Suzuki, Akitsu; Matsushita, Asami; Umeda, Minako; Ishikawa, Makoto; Taketani, Yutaka; Takeda, Eiji; Arai, Hidekazu

    2014-01-01

    Increases in serum phosphorus levels and dietary phosphorus intake induces vascular calcification, arterial sclerosis and cardiovascular diseases. Limiting phosphorus intake is advisable, however, no assessment methods are capable of estimating dietary phosphorus intake. We hypothesized that urinary phosphorus excretion can be translated into estimation of dietary phosphorus intake, and we evaluated whether a 24-h urine collection method could estimate dietary phosphorus intake. Thirty two healthy subjects were recruited for this study. Subjects collected urine samples over 24 h and weighed dietary records. We calculated dietary protein intake and phosphorus intake from dietary records and urine collection, and investigated associations between the two methods in estimating protein and phosphorus intake. Significant positive correlations were observed between dietary records and UC for protein and phosphorus intake. The average intakes determined from dietary records were significantly higher than from urine collection for both protein and phosphorus. There was a significant positive correlation between both the phosphorus and protein difference in dietary records and urine collection. The phosphorus-protein ratio in urine collection was significantly higher than in dietary records. Our data indicated that the 24-h urine collection method can estimate the amount of dietary phosphorus intake, and the results were superior to estimation by weighed dietary record. PMID:25120281

  6. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  7. Use of diluted urine for cultivation of Chlorella vulgaris.

    Science.gov (United States)

    Jaatinen, Sanna; Lakaniemi, Aino-Maija; Rintala, Jukka

    2016-01-01

    Our aim was to study the biomass growth of microalga Chlorella vulgaris using diluted human urine as a sole nutrient source. Batch cultivations (21 days) were conducted in five different urine dilutions (1:25-1:300), in 1:100-diluted urine as such and with added trace elements, and as a reference, in artificial growth medium. The highest biomass density was obtained in 1:100-diluted urine with and without additional trace elements (0.73 and 0.60 g L(-1), respectively). Similar biomass growth trends and densities were obtained with 1:25- and 1:300-diluted urine (0.52 vs. 0.48 gVSS L(-1)) indicating that urine at dilution 1:25 can be used to cultivate microalgal based biomass. Interestingly, even 1:300-diluted urine contained sufficiently nutrients and trace elements to support biomass growth. Biomass production was similar despite pH-variation from < 5 to 9 in different incubations indicating robustness of the biomass growth. Ammonium formation did not inhibit overall biomass growth. At the beginning of cultivation, the majority of the biomass consisted of living algal cells, while towards the end, their share decreased and the estimated share of bacteria and cell debris increased.

  8. Urine Trefoil Factors as Prognostic Biomarkers in Chronic Kidney Disease.

    Science.gov (United States)

    Yamanari, Toshio; Sugiyama, Hitoshi; Tanaka, Keiko; Morinaga, Hiroshi; Kitagawa, Masashi; Onishi, Akifumi; Ogawa-Akiyama, Ayu; Kano, Yuzuki; Mise, Koki; Ohmoto, Yasukazu; Shikata, Kenichi; Wada, Jun

    2018-01-01

    Trefoil factor family (TFF) peptides are increased in serum and urine in patients with chronic kidney disease (CKD). However, whether the levels of TFF predict the progression of CKD remains to be elucidated. We determined the TFF levels using peptide-specific ELISA in spot urine samples and performed a prospective cohort study. The association between the levels of urine TFFs and other urine biomarkers as well as the renal prognosis was analyzed in 216 CKD patients (mean age: 53.7 years, 47.7% female, 56.9% with chronic glomerulonephritis, and mean eGFR: 58.5 ml/min/1.73 m 2 ). The urine TFF1 and TFF3 levels significantly increased with the progression of CKD stages, but not the urine TFF2 levels. The TFF1 and TFF3 peptide levels predicted the progression of CKD ≥ stage 3b by ROC analysis (AUC 0.750 and 0.879, resp.); however, TFF3 alone predicted CKD progression in a multivariate logistic regression analysis (odds ratio 3.854, 95% confidence interval 1.316-11.55). The Kaplan-Meier survival curves demonstrated that patients with a higher TFF1 and TFF3 alone, or in combination with macroalbuminuria, had a significantly worse renal prognosis. The data suggested that urine TFF peptides are associated with renal progression and the outcomes in patients with CKD.

  9. Immunoelectron microscopy in embryos.

    Science.gov (United States)

    Sierralta, W D

    2001-05-01

    Immunogold labeling of proteins in sections of embryos embedded in acrylate media provides an important analytical tool when the resolving power of the electron microscope is required to define sites of protein function. The protocol presented here was established to analyze the role and dynamics of the activated protein kinase C/Rack1 regulatory system in the patterning and outgrowth of limb bud mesenchyme. With minor changes, especially in the composition of the fixative solution, the protocol should be easily adaptable for the postembedding immunogold labeling of any other antigen in tissues of embryos of diverse species. Quantification of the labeling can be achieved by using electron microscope systems capable of supporting digital image analysis. Copyright 2001 Academic Press.

  10. Mass spectrometric based approaches in urine metabolomics and biomarker discovery.

    Science.gov (United States)

    Khamis, Mona M; Adamko, Darryl J; El-Aneed, Anas

    2017-03-01

    Urine metabolomics has recently emerged as a prominent field for the discovery of non-invasive biomarkers that can detect subtle metabolic discrepancies in response to a specific disease or therapeutic intervention. Urine, compared to other biofluids, is characterized by its ease of collection, richness in metabolites and its ability to reflect imbalances of all biochemical pathways within the body. Following urine collection for metabolomic analysis, samples must be immediately frozen to quench any biogenic and/or non-biogenic chemical reactions. According to the aim of the experiment; sample preparation can vary from simple procedures such as filtration to more specific extraction protocols such as liquid-liquid extraction. Due to the lack of comprehensive studies on urine metabolome stability, higher storage temperatures (i.e. 4°C) and repetitive freeze-thaw cycles should be avoided. To date, among all analytical techniques, mass spectrometry (MS) provides the best sensitivity, selectivity and identification capabilities to analyze the majority of the metabolite composition in the urine. Combined with the qualitative and quantitative capabilities of MS, and due to the continuous improvements in its related technologies (i.e. ultra high-performance liquid chromatography [UPLC] and hydrophilic interaction liquid chromatography [HILIC]), liquid chromatography (LC)-MS is unequivocally the most utilized and the most informative analytical tool employed in urine metabolomics. Furthermore, differential isotope tagging techniques has provided a solution to ion suppression from urine matrix thus allowing for quantitative analysis. In addition to LC-MS, other MS-based technologies have been utilized in urine metabolomics. These include direct injection (infusion)-MS, capillary electrophoresis-MS and gas chromatography-MS. In this article, the current progresses of different MS-based techniques in exploring the urine metabolome as well as the recent findings in providing

  11. Fluctuations of nickel concentrations in urine of electroplating workers

    International Nuclear Information System (INIS)

    Bernacki, E.J.; Zygowicz, E.; Sunderman, F.W. Jr.

    1980-01-01

    Nickel analyses were performed by electrothermal atomic absorption spectrometry upon urine specimens obtained from electroplating workers at the beginning, middle and end of the work-shift. The means (+- S.D.) for nickel concentrations in urine specimens from seven electroplating workers on three regular workdays were: 34 +- 32 μg/L (pre-shift); 64 +- μg/L (mid-shift) and 46 +- μg/L (end-shift), compared to 2.7 +- 1.6 μg/L (pre-shift) in 19 controls (hospital workers). Nickel concentrations in urine specimens from six electroplating workers on the first workday after a two-week vacation averaged: 5 +- 3 μg/L (pre-shift); 9 +- 6 μg/L (mid-shift), and 12 +- 6 μg/L (end-shift). Nickel concentrations in personal air samples (seven hours) collected from the breathing zones of five electroplating workers on three regular workdays averaged 9.3 +- 4.4 μg/m 3 . Nickel concentrations in the air samples were correlated with nickel concentrations in end-shift urine specimens (corr. coef. = 0.70; P < 0.05), but were not correlated with nickel concentrations in pre-shift or mid-shift urine specimens. In view of the fluctuations of urine nickel concentrations that occur during the work-shift, the authors recommend that nickel analyses of eight hour urine specimens be used routinely to monitor occupational exposures to nickel. In situations where timed urine collections are impractical, analyses of end-shift urine specimens are the best alternative

  12. Metabolites of cannabidiol identified in human urine.

    Science.gov (United States)

    Harvey, D J; Mechoulam, R

    1990-03-01

    1. Urine from a dystonic patient treated with cannabidiol (CBD) was examined by g.l.c.-mass spectrometry for CBD metabolites. Metabolites were identified as their trimethylsilyl (TMS), [2H9]TMS, and methyl ester/TMS derivatives and as the TMS derivatives of the product of lithium aluminium deuteride reduction. 2. Thirty-three metabolites were identified in addition to unmetabolized CBD, and a further four metabolites were partially characterized. 3. The major metabolic route was hydroxylation and oxidation at C-7 followed by further hydroxylation in the pentyl and propenyl groups to give 1"-, 2"-, 3"-, 4"- and 10-hydroxy derivatives of CBD-7-oic acid. Other metabolites, mainly acids, were formed by beta-oxidation and related biotransformations from the pentyl side-chain and these were also hydroxylated at C-6 or C-7. The major oxidized metabolite was CBD-7-oic acid containing a hydroxyethyl side-chain. 4. Two 8,9-dihydroxy compounds, presumably derived from the corresponding epoxide were identified. 5. Also present were several cyclized cannabinoids including delta-6- and delta-1-tetrahydrocannabinol and cannabinol. 6. This is the first metabolic study of CBD in humans; most observed metabolic routes were typical of those found for CBD and related cannabinoids in other species.

  13. Corn stalk as matrix in decomposting toilet for treating urine and feces

    Science.gov (United States)

    Sintawardani, N.; Nilawati, D.; Astuti, J. T.

    2017-03-01

    Bio-Toilet technology (BT) which is appropriate for the habits of Indonesian people has been studied and developed. BT is a dry toilet technology commonly uses ligno-cellulosic waste materials as matrix to facilitate the growth of natural microbes. In aerobic condition, microbes degrade feces and urine. Mineral as the leftover of feces and urine, such as nitrogen (N), phosphorus (P), and potassium (K) remain in the rest of matrix waste. After certain period. matrix can be harvested and used as soil conditioner. BT uses much less water, mobile, and very useful to be applied in areas where water availability is limited. BT type with different capacities, user amounts and mixing systems has been developed using sawdust for matrix. Since corn stalk is categorized as useless and priceless waste, its application in BT is challenging. Performance of BT with corn stalk as matrix to degrade feces and urine of carnivore imitating the human waste was observed. BT M-15 manual mixing type with paddle was filled with chopped corn stalk as much as 45% of total volume. This BT was designed for 15 person as users per day if 80% reactor volume was filled with ligno-cellulosic matrix. It is assumed that 150 g of feces are discharged once per person/day and 1000 mL of urine 6-8 times per day. Start up process was made in the beginning to initialize the needed microbes in the reactor (matrix). The discharge of feces and urine were increased slowly and gradually the users were increased from 1 to 4 users per day. Performance of BT was indicated by the change in the pile that showed by moisture content, temperature and pH. C/N ratio in matrix decreased significantly from 43 to 17. This result showed that the corn stalk could be used as matrix in BT.

  14. Urine RAS components in mice and people with type 1 diabetes and chronic kidney disease.

    Science.gov (United States)

    Wysocki, Jan; Goodling, Anne; Burgaya, Mar; Whitlock, Kathryn; Ruzinski, John; Batlle, Daniel; Afkarian, Maryam

    2017-08-01

    The pathways implicated in diabetic kidney disease (DKD) are largely derived from animal models. To examine if alterations in renin-angiotensin system (RAS) in humans are concordant with those in rodent models, we measured concentration of angiotensinogen (AOG), cathepsin D (CTSD), angiotensin-converting enzyme (ACE), and ACE2 and enzymatic activities of ACE, ACE2, and aminopeptidase-A in FVB mice 13-20 wk after treatment with streptozotocin ( n = 9) or vehicle ( n = 15) and people with long-standing type 1 diabetes, with ( n = 37) or without ( n = 81) DKD. In streptozotocin-treated mice, urine AOG and CTSD were 10.4- and 3.0-fold higher than in controls, respectively ( P animals ( P animals ( P = 0.017). Compared with people without DKD, those with DKD had higher urine AOG (170 vs. 15 μg/g) and CTSD (147 vs. 31 μg/g). In people with DKD, urine ACE concentration was 1.8-fold higher (1.4 vs. 0.8 μg/g in those without DKD), while its enzymatic activity was 0.6-fold lower (1.0 vs. 1.6 × 10 9 RFU/g in those without DKD). Lower ACE activity, but not ACE protein concentration, was associated with ACE inhibitor (ACEI) treatment. After adjustment for clinical covariates, AOG, CTSD, ACE concentration, and ACE activity remained associated with DKD. In conclusion, in mice with streptozotocin-induced diabetes and in humans with DKD, urine concentrations and enzymatic activities of several RAS components are concordantly increased, consistent with enhanced RAS activity and greater angiotensin II formation. ACEI use was associated with a specific reduction in urine ACE activity, not ACE protein concentration, suggesting that it may be a marker of exposure to this widely-used therapy. Copyright © 2017 the American Physiological Society.

  15. Reconstruction of the neuromuscular system of the swimming-type larva of Loxosomella atkinsae (Entoprocta) as inferred by fluorescence labelling and confocal microscopy

    DEFF Research Database (Denmark)

    Fuchs, Judith; Wanninger, Andreas Wilhelm Georg

    2008-01-01

    Entoprocta is one of the most enigmatic phyla of the Animal Kingdom. The morphology of their larvae has been little investigated, with details on the larval musculature lacking entirely and immunocytochemical data on the larval nervous system available for only 2 species. Here, we provide the first...

  16. Scanning Tunneling Microscopy - image interpretation

    International Nuclear Information System (INIS)

    Maca, F.

    1998-01-01

    The basic ideas of image interpretation in Scanning Tunneling Microscopy are presented using simple quantum-mechanical models and supplied with examples of successful application. The importance is stressed of a correct interpretation of this brilliant experimental surface technique

  17. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, Virginia M., E-mail: vweaver@jhsph.edu [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Vargas, Gonzalo García [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Secretaría de Salud del Estado de Coahuila, Coahuila, México (Mexico); Silbergeld, Ellen K. [Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rothenberg, Stephen J. [Instituto Nacional de Salud Publica, Centro de Investigacion en Salud Poblacional, Cuernavaca, Morelos (Mexico); Fadrowski, Jeffrey J. [Johns Hopkins University School of Medicine, Baltimore, MD (United States); Welch Center for Prevention, Epidemiology, and Clinical Research, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD (United States); Rubio-Andrade, Marisela [Faculty of Medicine, University of Juárez of Durango State, Durango (Mexico); Parsons, Patrick J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, Albany, NY (United States); Steuerwald, Amy J. [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY (United States); and others

    2014-07-15

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m{sup 2}; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed.

  18. Impact of urine concentration adjustment method on associations between urine metals and estimated glomerular filtration rates (eGFR) in adolescents

    International Nuclear Information System (INIS)

    Weaver, Virginia M.; Vargas, Gonzalo García; Silbergeld, Ellen K.; Rothenberg, Stephen J.; Fadrowski, Jeffrey J.; Rubio-Andrade, Marisela; Parsons, Patrick J.; Steuerwald, Amy J.

    2014-01-01

    Positive associations between urine toxicant levels and measures of glomerular filtration rate (GFR) have been reported recently in a range of populations. The explanation for these associations, in a direction opposite that of traditional nephrotoxicity, is uncertain. Variation in associations by urine concentration adjustment approach has also been observed. Associations of urine cadmium, thallium and uranium in models of serum creatinine- and cystatin-C-based estimated GFR (eGFR) were examined using multiple linear regression in a cross-sectional study of adolescents residing near a lead smelter complex. Urine concentration adjustment approaches compared included urine creatinine, urine osmolality and no adjustment. Median age, blood lead and urine cadmium, thallium and uranium were 13.9 years, 4.0 μg/dL, 0.22, 0.27 and 0.04 g/g creatinine, respectively, in 512 adolescents. Urine cadmium and thallium were positively associated with serum creatinine-based eGFR only when urine creatinine was used to adjust for urine concentration (β coefficient=3.1 mL/min/1.73 m 2 ; 95% confidence interval=1.4, 4.8 per each doubling of urine cadmium). Weaker positive associations, also only with urine creatinine adjustment, were observed between these metals and serum cystatin-C-based eGFR and between urine uranium and serum creatinine-based eGFR. Additional research using non-creatinine-based methods of adjustment for urine concentration is necessary. - Highlights: • Positive associations between urine metals and creatinine-based eGFR are unexpected. • Optimal approach to urine concentration adjustment for urine biomarkers uncertain. • We compared urine concentration adjustment methods. • Positive associations observed only with urine creatinine adjustment. • Additional research using non-creatinine-based methods of adjustment needed

  19. Diffractive elements performance in chromatic confocal microscopy

    International Nuclear Information System (INIS)

    Garzon, J; Duque, D; Alean, A; Toledo, M; Meneses, J; Gharbi, T

    2011-01-01

    The Confocal Laser Scanning Microscopy (CLSM) has been widely used in the semiconductor industry and biomedicine because of its depth discrimination capability. Subsequent to this technique has been developed in recent years Chromatic Confocal Microscopy. This method retains the same principle of confocal and offers the added advantage of removing the axial movement of the moving system. This advantage is usually accomplished with an optical element that generates a longitudinal chromatic aberration and a coding system that relates the axial position of each point of the sample with the wavelength that is focused on each. The present paper shows the performance of compact chromatic confocal microscope when some different diffractive elements are used for generation of longitudinal chromatic aberration. Diffractive elements, according to the process and manufacturing parameters, may have different diffraction efficiency and focus a specific wavelength in a specific focal position. The performance assessment is carried out with various light sources which exhibit an incoherent behaviour and a broad spectral width.

  20. PROTON MICROSCOPY AT FAIR

    International Nuclear Information System (INIS)

    Merrill, F. E.; Mariam, F. G.; Golubev, A. A.; Turtikov, V. I.; Varentsov, D.

    2009-01-01

    Proton radiography was invented in the 1990's at Los Alamos National Laboratory (LANL) as a diagnostic to study dynamic material properties under extreme pressures, strain and strain rate. Since this time hundreds of dynamic proton radiography experiments have been performed at LANL and a facility has been commissioned at the Institute for Theoretical and Experimental Physics (ITEP) in Russia for similar applications in dynamic material studies. Recently an international effort has investigated a new proton radiography capability for the study of dynamic material properties at the Facility for Anti-proton and Ion Research (FAIR) located in Darmstadt, Germany. This new Proton microscope for FAIR(PRIOR) will provide radiographic imaging of dynamic systems with unprecedented spatial, temporal and density resolution, resulting in a window for understanding dynamic material properties at new length scales. It is also proposed to install the PRIOR system at the GSI Helmholtzzentrum fuer Schwerionenforschung before installation at FAIR for dynamic experiments with different drivers including high explosives, pulsed power and lasers. The design of the proton microscope and expected radiographic performance is presented.

  1. Quantitative imaging of bilirubin by photoacoustic microscopy

    Science.gov (United States)

    Zhou, Yong; Zhang, Chi; Yao, Da-Kang; Wang, Lihong V.

    2013-03-01

    Noninvasive detection of both bilirubin concentration and its distribution is important for disease diagnosis. Here we implemented photoacoustic microscopy (PAM) to detect bilirubin distribution. We first demonstrate that our PAM system can measure the absorption spectra of bilirubin and blood. We also image bilirubin distributions in tissuemimicking samples, both without and with blood mixed. Our results show that PAM has the potential to quantitatively image bilirubin in vivo for clinical applications.

  2. Electron microscopy of nanostructured semiconductor materials

    International Nuclear Information System (INIS)

    Neumann, Wolfgang

    2003-01-01

    For various material systems of low dimensions, including multilayers, islands, and quantum dots, the potential applicability of transmission electron microscopy (TEM) is demonstrated. Conventional TEM is applied to elucidate size, shape, and arrangement of nanostructures, whereas high-resolution imaging is used for visualizing their atomic structure. In addition, microchemical peculiarities of the nanoscopic objects are investigated by analytical TEM techniques (energy-filtered TEM, energy-dispersive X-ray spectroscopy)

  3. Electron microscopy and auger spectroscopy study of the wetting of the grain boundaries in the systems Mo-Pb, Mo-Sn, Mo-Ni and Ni-Pb; Etude par microscopie electronique et spectroscopie auger du mouillage des joints de grains dans les systemes Mo-Pb, Mo-Sn, Mo-Ni et Ni-Pb

    Energy Technology Data Exchange (ETDEWEB)

    Charai, A. [Faculte des Sciences et Techniques de Saint Jerome, Lab. TECSEN, UMR 6122 du CNRS, 13 - Marseille (France); Kutcherinenko, I.; Priester, L. [Paris-11 Univ., ISMA, 91 - Orsay (France); Penisson, J.M. [CEA Grenoble, Dept. de Recherche Fondamentale sur la Matiere Condensee, DRFMC-SP2M, 38 (France); Pontikis, V. [Centre National de la Recherche Scientifique (CNRS), Centre d' Etudes de Chimie Metallurgique, 94 - Vitry-sur-Seine (France); Wolski, K. [Ecole NationaleSuperieure des Mines de Saint Etienne, Centre SMS/MPI, URA 1884 du CNRS, 42 - Saint Etienne (France); Vystavel, T. [Academy of Sciences of Czech Republic, Institute of Physics, Praha (Czech Republic)

    2002-09-01

    Understanding the mechanism of the intergranular penetration of a liquid phase into a metallic solid is an important problem. The structural and chemical characterization of nano-metric films at grain boundaries is now possible by using high resolution electron microscopy associated with X-ray micro-analysis, electron energy loss spectroscopy and Auger spectroscopy. In order to study this problem, two different classes of model materials were selected according to their crystallographic structure: a bcc metal (molybdenum) and an fcc one (nickel). The wetting element was either lead or tin or nickel. In a first approach, the metallic matrix was polycrystalline. The conditions in which the liquid phase penetrates into the grain boundaries were studied by using special preparation and observation techniques. In particular, the use of a Focused Ion Beam microscope (FIB) allowed the preparation of thin foils located very precisely inside the matrix as well as multi-scale observations. These specimens were further observed in electron microscopy with a very high resolution. (authors)

  4. Ultra-trace determination of neptunium-237 and plutonium isotopes in urine samples by compact accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dai, X.; Christl, M.; Kramer-Tremblay, S., E-mail: sheila.kramer-tremblay@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Synal, H-A. [ETH Zurich, Lab. of Ion Beam Physics, Zurich (Switzerland)

    2015-12-15

    Ultra-trace analysis of actinides, such as Pu isotopes and {sup 237}Np, in bioassay samples is often needed for radiation protection programs at nuclear facilities. Accelerator mass spectrometry (AMS), particularly the compact ETH Zurich system “Tandy”, has evolved over the years as one of the most sensitive, selective, and robust techniques for actinide analysis. Employment of the AMS technique can reduce the demands on sample preparation chemistry and increase sample analysis throughput, due to very low instrumental detection limit, high rejection of interferences, and low susceptibility to adverse sample matrices. Initial research and development tests were performed to explore and demonstrate the analytical capability of AMS for Pu and Np urine bioassay. In this study, urine samples spiked with femtogram levels of Np and Pu isotopes were prepared and measured using compact ETH AMS system and the results showed excellent analytical capability for measuring Np and Pu isotopes at femtogram/litre levels in urine. (author)

  5. Measurement of organically bound tritium in urine and feces

    International Nuclear Information System (INIS)

    Trivedi, A.; Duong, T.; Leon, J.W.; Linauskas, S.H.

    1993-11-01

    A bioassay method was developed for directly measuring organically bound tritium (OBT) in urine and feces. Samples first undergo low-temperature distillation and vacuum separation to isolate tritiated water (HTO) and exchangeable tritium. This is followed by converting the non-exchangeable tritium (i.e., OBT) into HTO through oxygen combustion. The method was investigated to: optimise the sample preparation procedures; establish OBT recovery (64% ± 7% for urine and 71% ± 8% for feces); and, determine the detection limit for OBT in urine (0.3 Bq · g -1 ) and feces (5 Bq · g -1 ). The method was evaluated for error sources that are associated with the exchange between HTO and OBT. It is concluded that this bioassay method can reliably measure OBT in urine and feces within the range of ± 10%

  6. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  7. Bilirubin in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2 nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Bilirubin (Urine); 86–87 p. Lab ...

  8. Urine sampling techniques in symptomatic primary-care patients

    DEFF Research Database (Denmark)

    Holm, Anne; Aabenhus, Rune

    2016-01-01

    in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. Conclusions: At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However......Background: Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection...... a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. Results: We included...

  9. Isolation and identification of two galangin metabolites from rat urine ...

    African Journals Online (AJOL)

    Isolation and identification of two galangin metabolites from rat urine and determination of their in vitro hypolipidemic activity. Xuguang Zhang, Shouqian Cheng, Hailong Li, Xiaopo Zhang, Feng Chen, Youbin Li, Junqing Zhang, Yinfeng Tan ...

  10. European guidelines for workplace drug testing in urine.

    Science.gov (United States)

    Taskinen, Sanna; Beck, Olof; Bosch, Tessa; Brcak, Michaela; Carmichael, Duncan; Fucci, Nadia; George, Claire; Piper, Mark; Salomone, Alberto; Schielen, Wim; Steinmeyer, Stefan; Weinmann, Wolfgang

    2017-06-01

    These European Guidelines for Workplace Drug Testing in Urine have been prepared and updated by the European Workplace Drug Testing Society (EWDTS). The first version of these urine guidelines was published in 2002. Since then, the guidelines have been followed by many laboratories in different European countries and their role has been essential particularly in countries lacking legislation for workplace drug testing. In 2014, the EWDTS started a guidelines updating project and published a new version of the urine guidelines in 2015. Here we represent this updated version of the urine guidelines. The European Guidelines are designed to establish best practice procedures whilst allowing individual countries to operate within the requirements of national customs and legislation. The EWDTS recommends that all European laboratories that undertake legally defensible workplace drug testing should use these guidelines as a template for accreditation. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Mest en urine: van afval naar waardevol product

    NARCIS (Netherlands)

    Bos, A.P.; Cornelissen, J.M.R.; Groot Koerkamp, P.W.G.

    2010-01-01

    Het gescheiden houden van mest en urine in de veehouderij belooft een reeks positieve effecten te geven, waarmee de veehouderij én de akkerbouw een duurzaamheidssprong kunnen maken. Maar dat lukt alleen als er veel praktijken tegelijkertijd veranderen.

  12. Mucus in Urine: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... is normal. An excess amount may indicate a urinary tract infection (UTI) or other medical condition. A test called urinalysis ... your urinalysis if you have symptoms of a UTI. These include: Frequent urge to urinate, but little ...

  13. Phenylbutyrate therapy for maple syrup urine disease.

    Science.gov (United States)

    Brunetti-Pierri, Nicola; Lanpher, Brendan; Erez, Ayelet; Ananieva, Elitsa A; Islam, Mohammad; Marini, Juan C; Sun, Qin; Yu, Chunli; Hegde, Madhuri; Li, Jun; Wynn, R Max; Chuang, David T; Hutson, Susan; Lee, Brendan

    2011-02-15

    Therapy with sodium phenylacetate/benzoate or sodium phenylbutyrate in urea cycle disorder patients has been associated with a selective reduction in branched-chain amino acids (BCAA) in spite of adequate dietary protein intake. Based on this clinical observation, we investigated the potential of phenylbutyrate treatment to lower BCAA and their corresponding α-keto acids (BCKA) in patients with classic and variant late-onset forms of maple syrup urine disease (MSUD). We also performed in vitro and in vivo experiments to elucidate the mechanism for this effect. We found that BCAA and BCKA are both significantly reduced following phenylbutyrate therapy in control subjects and in patients with late-onset, intermediate MSUD. In vitro treatment with phenylbutyrate of control fibroblasts and lymphoblasts resulted in an increase in the residual enzyme activity, while treatment of MSUD cells resulted in the variable response which did not simply predict the biochemical response in the patients. In vivo phenylbutyrate increases the proportion of active hepatic enzyme and unphosphorylated form over the inactive phosphorylated form of the E1α subunit of the branched-chain α-keto acid dehydrogenase complex (BCKDC). Using recombinant enzymes, we show that phenylbutyrate prevents phosphorylation of E1α by inhibition of the BCKDC kinase to activate BCKDC overall activity, providing a molecular explanation for the effect of phenylbutyrate in a subset of MSUD patients. Phenylbutyrate treatment may be a valuable treatment for reducing the plasma levels of neurotoxic BCAA and their corresponding BCKA in a subset of MSUD patients and studies of its long-term efficacy are indicated.

  14. Surface glycosylation profiles of urine extracellular vesicles.

    Directory of Open Access Journals (Sweden)

    Jared Q Gerlach

    Full Text Available Urinary extracellular vesicles (uEVs are released by cells throughout the nephron and contain biomolecules from their cells of origin. Although uEV-associated proteins and RNA have been studied in detail, little information exists regarding uEV glycosylation characteristics. Surface glycosylation profiling by flow cytometry and lectin microarray was applied to uEVs enriched from urine of healthy adults by ultracentrifugation and centrifugal filtration. The carbohydrate specificity of lectin microarray profiles was confirmed by competitive sugar inhibition and carbohydrate-specific enzyme hydrolysis. Glycosylation profiles of uEVs and purified Tamm Horsfall protein were compared. In both flow cytometry and lectin microarray assays, uEVs demonstrated surface binding, at low to moderate intensities, of a broad range of lectins whether prepared by ultracentrifugation or centrifugal filtration. In general, ultracentrifugation-prepared uEVs demonstrated higher lectin binding intensities than centrifugal filtration-prepared uEVs consistent with lesser amounts of co-purified non-vesicular proteins. The surface glycosylation profiles of uEVs showed little inter-individual variation and were distinct from those of Tamm Horsfall protein, which bound a limited number of lectins. In a pilot study, lectin microarray was used to compare uEVs from individuals with autosomal dominant polycystic kidney disease to those of age-matched controls. The lectin microarray profiles of polycystic kidney disease and healthy uEVs showed differences in binding intensity of 6/43 lectins. Our results reveal a complex surface glycosylation profile of uEVs that is accessible to lectin-based analysis following multiple uEV enrichment techniques, is distinct from co-purified Tamm Horsfall protein and may demonstrate disease-specific modifications.

  15. Estimating population salt intake in India using spot urine samples.

    Science.gov (United States)

    Petersen, Kristina S; Johnson, Claire; Mohan, Sailesh; Rogers, Kris; Shivashankar, Roopa; Thout, Sudhir Raj; Gupta, Priti; He, Feng J; MacGregor, Graham A; Webster, Jacqui; Santos, Joseph Alvin; Krishnan, Anand; Maulik, Pallab K; Reddy, K Srinath; Gupta, Ruby; Prabhakaran, Dorairaj; Neal, Bruce

    2017-11-01

    To compare estimates of mean population salt intake in North and South India derived from spot urine samples versus 24-h urine collections. In a cross-sectional survey, participants were sampled from slum, urban and rural communities in North and in South India. Participants provided 24-h urine collections, and random morning spot urine samples. Salt intake was estimated from the spot urine samples using a series of established estimating equations. Salt intake data from the 24-h urine collections and spot urine equations were weighted to provide estimates of salt intake for Delhi and Haryana, and Andhra Pradesh. A total of 957 individuals provided a complete 24-h urine collection and a spot urine sample. Weighted mean salt intake based on the 24-h urine collection, was 8.59 (95% confidence interval 7.73-9.45) and 9.46 g/day (8.95-9.96) in Delhi and Haryana, and Andhra Pradesh, respectively. Corresponding estimates based on the Tanaka equation [9.04 (8.63-9.45) and 9.79 g/day (9.62-9.96) for Delhi and Haryana, and Andhra Pradesh, respectively], the Mage equation [8.80 (7.67-9.94) and 10.19 g/day (95% CI 9.59-10.79)], the INTERSALT equation [7.99 (7.61-8.37) and 8.64 g/day (8.04-9.23)] and the INTERSALT equation with potassium [8.13 (7.74-8.52) and 8.81 g/day (8.16-9.46)] were all within 1 g/day of the estimate based upon 24-h collections. For the Toft equation, estimates were 1-2 g/day higher [9.94 (9.24-10.64) and 10.69 g/day (9.44-11.93)] and for the Kawasaki equation they were 3-4 g/day higher [12.14 (11.30-12.97) and 13.64 g/day (13.15-14.12)]. In urban and rural areas in North and South India, most spot urine-based equations provided reasonable estimates of mean population salt intake. Equations that did not provide good estimates may have failed because specimen collection was not aligned with the original method.

  16. Monitoring human papillomavirus prevalence in urine samples: a review

    Directory of Open Access Journals (Sweden)

    Enerly E

    2013-03-01

    Full Text Available Espen Enerly, Cecilia Olofsson, Mari NygårdDepartment of Research, Cancer Registry of Norway, Oslo, NorwayAbstract: Human papillomavirus (HPV is the main cause of cervical cancer, and many countries now offer vaccination against HPV to girls by way of government-funded national immunization programs. Monitoring HPV prevalence in adolescents could offer a near-term biological measure of vaccine impact, and urine sampling may be an attractive large-scale method that could be used for this purpose. Our objective was to provide an overview of the literature on HPV DNA detection in urine samples, with an emphasis on adolescents. We searched the PubMed database using the terms “HPV” and “urine” and identified 21 female and 14 male study populations in which HPV prevalence in urine samples was reported, four of which included only asymptomatic female adolescents. We provide herein an overview of the recruitment setting, age, urine sampling procedure, lesion type, HPV assay, and HPV prevalence in urine samples and other urogenital samples for the studies included in this review. In female study populations, concordance for any HPV type and type-specific concordance in paired urine and cervical samples are provided in addition to sensitivity and specificity. We concluded that few studies on HPV prevalence in urine samples have been performed in asymptomatic female adolescent populations but that urine samples may be a useful alternative to cervical samples to monitor changes in HPV prevalence in females in the post-HPV vaccination era. However, care should be taken when extrapolating HPV findings from urine samples to the cervix. In males, urine samples do not seem to be optimal for monitoring HPV prevalence due to a low human genomic DNA content and HPV DNA detection rate compared to other urogenital sites. In each situation the costs and benefits of HPV DNA detection in urine compared to alternative monitoring options should be carefully

  17. Use of a Chagas Urine Nanoparticle Test (Chunap) to Correlate with Parasitemia Levels in T. cruzi/HIV Co-infected Patients

    Science.gov (United States)

    Castro-Sesquen, Yagahira E.; Gilman, Robert H.; Mejia, Carolina; Clark, Daniel E.; Choi, Jeong; Reimer-McAtee, Melissa J.; Castro, Rosario; Valencia-Ayala, Edward; Flores, Jorge; Bowman, Natalie; Castillo-Neyra, Ricardo; Torrico, Faustino; Liotta, Lance; Bern, Caryn; Luchini, Alessandra

    2016-01-01

    Background Early diagnosis of reactivated Chagas disease in HIV patients could be lifesaving. In Latin America, the diagnosis is made by microscopical detection of the T. cruzi parasite in the blood; a diagnostic test that lacks sensitivity. This study evaluates if levels of T. cruzi antigens in urine, determined by Chunap (Chagas urine nanoparticle test), are correlated with parasitemia levels in T. cruzi/HIV co-infected patients. Methodology/Principal Findings T. cruzi antigens in urine of HIV patients (N = 55: 31 T. cruzi infected and 24 T. cruzi serology negative) were concentrated using hydrogel particles and quantified by Western Blot and a calibration curve. Reactivation of Chagas disease was defined by the observation of parasites in blood by microscopy. Parasitemia levels in patients with serology positive for Chagas disease were classified as follows: High parasitemia or reactivation of Chagas disease (detectable parasitemia by microscopy), moderate parasitemia (undetectable by microscopy but detectable by qPCR), and negative parasitemia (undetectable by microscopy and qPCR). The percentage of positive results detected by Chunap was: 100% (7/7) in cases of reactivation, 91.7% (11/12) in cases of moderate parasitemia, and 41.7% (5/12) in cases of negative parasitemia. Chunap specificity was found to be 91.7%. Linear regression analysis demonstrated a direct relationship between parasitemia levels and urine T. cruzi antigen concentrations (p 105 pg was chosen to determine patients with reactivation of Chagas disease (7/7). Antigenuria levels were 36.08 times (95% CI: 7.28 to 64.88) higher in patients with CD4+ lymphocyte counts below 200/mL (p = 0.016). No significant differences were found in HIV loads and CD8+ lymphocyte counts. Conclusion Chunap shows potential for early detection of Chagas reactivation. With appropriate adaptation, this diagnostic test can be used to monitor Chagas disease status in T. cruzi/HIV co-infected patients. PMID:26919324

  18. A framework for creating realistic synthetic fluorescence microscopy image sequences

    CSIR Research Space (South Africa)

    Mabaso, M

    2016-02-01

    Full Text Available Fluorescence microscopy imaging is an important tool in modern biological research, allowing insights into the processes of biological systems. Automated image analysis algorithms help in extracting information from these images. Validation...

  19. System and method for controlling depth of imaging in tissues using fluorescence microscopy under ultraviolet excitation following staining with fluorescing agents

    Science.gov (United States)

    Levenson, Richard; Demos, Stavros

    2018-05-08

    A method is disclosed for analyzing a thin tissue sample and adapted to be supported on a slide. The tissue sample may be placed on a slide and exposed to one or more different exogenous fluorophores excitable in a range of about 300 nm-200 nm, and having a useful emission band from about 350 nm-900 nm, and including one or more fluorescent dyes or fluorescently labeled molecular probes that accumulate in tissue or cellular components. The fluorophores may be excited with a first wavelength of UV light between about 200 nm-290 nm. An optical system collects emissions from the fluorophores at a second wavelength, different from the first wavelength, which are generated in response to the first wavelength of UV light, to produce an image for analysis.

  20. Sample handling for mass spectrometric proteomic investigations of human urine.

    Science.gov (United States)

    Petri, Anette Lykke; Høgdall, Claus; Christensen, Ib Jarle; Simonsen, Anja Hviid; T'jampens, Davy; Hellmann, Marja-Leena; Kjaer, Susanne Krüger; Fung, Eric T; Høgdall, Estrid

    2008-09-01

    Because of its non-invasive sample collection method, human urine is an attractive biological material both for discovering biomarkers and for use in future screening trials for different diseases. Before urine can be used for these applications, standardized protocols for sample handling that optimize protein stability are required. In this explorative study, we examine the influence of different urine collection methods, storage temperatures, storage times, and repetitive freeze-thaw procedures on the protein profiles obtained by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Prospectively collected urine samples from 11 women were collected as either morning or midday specimens. The effects of storage temperature, time to freezing, and freeze-thaw cycles were assessed by calculating the number, intensity, and reproducibility of peaks visualized by SELDI-TOF-MS. On the CM10 array, 122 peaks were detected and 28 peaks were found to be significantly different between urine types, storage temperature and time to freezing. On the IMAC-Cu array, 65 peaks were detected and 1 peak was found to be significantly different according to time to freezing. No significant differences were demonstrated for freeze-thaw cycles. Optimal handling and storage conditions are necessary in clinical urine proteomic investigations. Collection of urine with a single and consistently performed protocol is needed to reduce analytical bias. Collecting only one urine type, which is stored for a limited period at 4°C until freezing at -80°C prior to analysis will provide the most stable profiles. Copyright © 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Direct measurement of tritium in urine by liquid scintillation method

    International Nuclear Information System (INIS)

    Zhang Caihong; Wen Qinghua; Chen Kefei; Li Huaixin

    1999-01-01

    The author introduces the method for direct measurement of tritium concentration in urine using liquid scintillation. Effects of sampling containers, store patterns and storage time are studied. Meanwhile, results of two methods are compared with direct measurement method and oxidation distillation method. The results shows that direct measurement method is a economic and simple method, which can meet the need of determination of urine tritium for NPP workers. There is no significant difference compared with the data obtained by oxidation distillation method

  2. Stability studies of amphetamine and ephedrine derivatives in urine.

    Science.gov (United States)

    Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R

    2006-10-20

    Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.

  3. Is specific gravity a good estimate of urine osmolality?

    Science.gov (United States)

    Imran, Sethi; Eva, Goldwater; Christopher, Shutty; Flynn, Ethan; Henner, David

    2010-01-01

    Urine specific gravity (USG) is often used by clinicians to estimate urine osmolality. USG is measured either by refractometry or by reagent strip. We studied the correlation of USG obtained by either method with a concurrently obtained osmolality. Using our laboratory's records, we retrospectively gathered data on 504 urine specimens on patients on whom a simultaneously drawn USG and an osmolality were available. Out of these, 253 USG's were measured by automated refractometry and 251 USG's were measured by reagent strip. Urinalysis data on these subjects were used to determine the correlation between USG and osmolality, adjusting for other variables that may impact the relationship. The other variables considered were pH, protein, glucose, ketones, nitrates, bilirubin, urobilinogen, hemoglobin, and leukocyte esterase. The relationships were analyzed by linear regression. This study demonstrated that USG obtained by both reagent strip and refractometry had a correlation of approximately 0.75 with urine osmolality. The variables affecting the correlation included pH, ketones, bilirubin, urobilinogen, glucose, and protein for the reagent strip and ketones, bilirubin, and hemoglobin for the refractometry method. At a pH of 7 and with an USG of 1.010 predicted osmolality is approximately 300  mosm/kg/H(2)O for either method. For an increase in SG of 0.010, predicted osmolality increases by 182  mosm/kg/H(2) O for the reagent strip and 203  mosm/kg/H(2)O for refractometry. Pathological urines had significantly poorer correlation between USG and osmolality than "clean" urines. In pathological urines, direct measurement of urine osmolality should be used. © 2010 Wiley-Liss, Inc.

  4. Study about excretion of 210 Po in urine

    International Nuclear Information System (INIS)

    Fonseca Azeredo, A.M.G. da.

    1988-01-01

    The urine of mines's workers are analysed to detect the presence of 210 Po. The results was compared with the workers and with a control population. Cigarettes samples was analysed two and confirmed the 210 presence. The control population individuals were divided in smokers and non smokers and them urine was investigated the influence of the smoke in the 210 Po excretion. (L.M.J.)

  5. Uranium internal exposure evaluation based on urine assay data

    International Nuclear Information System (INIS)

    Lawrence, J.N.P.

    1984-09-01

    The difficulties in assessing internal exposures to uranium from urine assay data are described. A simplified application of the ICRP-30 and ICRP Lung Model concepts to the estimation of uranium intake is presented. A discussion follows on the development of a computer code utilizing the ICRP-30-based uranium elimination model with the existing urine assay information. The calculated uranium exposures from 1949 through 1983 are discussed. 13 references, 1 table

  6. Comparison of Urine and Oral Fluid for Workplace Drug Testing.

    Science.gov (United States)

    Casolin, Armand

    2016-09-01

    To determine the relative detection rates of urine versus oral fluid testing in a safety sensitive industry and the correlation with diagnosed substance use disorders and possible impairment at work. The trial involved 1,500 paired urine and oral fluid tests performed in accordance with Australian Standard/New Zealand Standard (AS/NZS) 4308:2008 and AS 4760:2006. Workers who returned a positive test were screened for substance use disorders, as defined by DSM-5, and for possible impairment at work following that particular episode of substance use. Substances were detected in 3.7% (n = 56) of urine samples and 0.5% (n = 8) of oral fluid samples (p < 0.0001). One worker (0.07%) had a substance detected on oral fluid alone versus 49 workers (3.3%) who had substances detected on urine alone. Twelve workers returned a positive result, defined as being consistent with the use of an illicit drug or a controlled substance without a clinical indication and prescription. Nine workers tested positive on urine alone, one on oral fluid alone and two on both (p = 0.0114). Of note, 6/11 workers who tested positive on urine had possible impairment at work and 2/11 had a substance use disorder versus 2/3 and 0/3, respectively, who tested positive on oral fluid. Urine drug testing performed in accordance with AS/NZS 4308:2008 is more likely to detect overall substance use and illicit drug use than oral fluid testing conducted in accordance with AS 4760:2006. Urine testing performed in accordance with AS/NZS 4308:2008 may also be more likely to detect workers with possible impairment at work and substance use disorders than oral fluid testing performed in accordance with AS 4760:2006. © The Author 2016. Published by Oxford University Press.

  7. Analysis of uranium in urine of persons occupationaly exposed

    International Nuclear Information System (INIS)

    Nunes, S.C.

    1985-01-01

    A technique of uranium analysis in urine of persons occupationaly exposed, using the fluorimetric method is proposed. Two procedures for the determination are presented: the first employs platinum dishes, obtaining a detection limit of 1 ppb and the second one, using aluminium dishes, shows a detection limit of 100 ppb. Uranium and urine physico-chemical characteristics are described, as well as norms for the exposition of workers to uranium. (M.A.C.) [pt

  8. Fluorimetric routine determination of uranium in urine samples

    International Nuclear Information System (INIS)

    Widua, L.; Schieferdecker, H.; Hezel, U.

    With a modified RA 2 reflectance accessory for the Zeiss PMQII/PMQ3 spectrophotometer, uranium in urine was detected with higher sensitivity. A quick method is now available with a detection limit of <2 μg U/1 urine for the determination of possible uranium incorporations, whose sensitivity meets the requirements of radiation protection. Compared with other extraction methods, the instrument outlay and the required working time are small. The total error of the method is below 5 percent

  9. Urine Culture in Uncomplicated UTI: Interpretation and Significance.

    Science.gov (United States)

    Stapleton, Ann E

    2016-05-01

    Acute uncomplicated urinary tract infection (UTI) is a common clinical problem, accounting for millions of outpatient visits in the USA annually. Although routinely obtaining urine cultures in UTI is not recommended, there are circumstances in which obtaining a pre-therapy culture may be warranted or chosen by clinicians, such as when indicated by the need for careful antimicrobial stewardship. This review focuses on understanding reasons for obtaining a pre-therapy culture, methods of collection, and appropriately interpreting urine culture data.

  10. Order-disorder phase transformations in quaternary pyrochlore oxide system: Investigated by X-ray diffraction, transmission electron microscopy and Raman spectroscopic techniques

    International Nuclear Information System (INIS)

    Radhakrishnan, A.N.; Prabhakar Rao, P.; Sibi, K.S.; Deepa, M.; Koshy, Peter

    2009-01-01

    Order-disorder transformations in a quaternary pyrochlore oxide system, Ca-Y-Zr-Ta-O, were studied by powder X-ray diffraction (XRD) method, transmission electron microscope (TEM) and FT-NIR Raman spectroscopic techniques. The solid solutions in different ratios, 4:1, 2:1, 1:1, 1:2, 1:4, 1:6, of CaTaO 3.5 and YZrO 3.5 were prepared by the conventional high temperature ceramic route. The XRD results and Rietveld analysis revealed that the crystal structure changed from an ordered pyrochlore structure to a disordered defect fluorite structure as the ratios of the solid solutions of CaTaO 3.5 and YZrO 3.5 were changed from 4:1 to 1:4. This structural transformation in the present system is attributed to the lowering of the average cation radius ratio, r A /r B as a result of progressive and simultaneous substitution of larger cation Ca 2+ for Y 3+ at A sites and smaller cation Ta 5+ for Zr 4+ at B sites. Raman spectroscopy and TEM analysis corroborated the XRD results. - Graphical abstract: Selected area electron diffraction (SAED) patterns showed highly ordered diffraction maxima with characteristic superlattice weak diffraction spots of the pyrochlore structure for (a) Ca 0.6 7Y 1.33 Zr 1.33 Ta 0.33 O 7 (C2YZT2) and bright diffraction maxima arranged in a ring pattern of the fluorite structure for (b) Ca 0.29 7Y 1.71 Zr 1.71 Ta 0.29 O 7 (CY6Z6T).

  11. COMPARATIVE STUDY OF CULTURE AND SENSITIVITY PATTERNS OF PRE OPERATIVE MID STREAM URINE WITH RENAL PELVIC URINE AND STONE TO PREDICT UROSEPSIS FOLLOWING PERCUTANEOUS NEPHROLITHOTOMY: A PROSPECTIVE CLINICAL STUDY

    Directory of Open Access Journals (Sweden)

    Bhargava Vardhana Reddy

    2015-11-01

    Full Text Available INTRODUCTION : Percutaneous nephrolithotomy (PCNL is the most frequently performed surgery for stone disease at our institution. Nearly 100 PCNL procedures are being performed in a year at our institution. Septicemia following PCNL can be catastrophic despite sterile preoperative urine and prophylactic antibiotics. Infected stones, obstructed kidneys , and comorbidit y have been held responsible. In this study we analyzed various culture specimens, namely Mid - stream urine (MSU, renal pelvic urine and crushed stones. MATERIALS AND METHODS : We performed a prospective clinical study in all our patients undergoing PCNL b etween January 2013 and December 2014. MSU was sent for culture and sensitivity testing (C&S one day prior to surgery. Percutaneous access into the ipsilateral pelvicaliceal system is achieved under image intensification using a fine, 14 gauge Kellet need le. Urine from the pelvicaliceal system is first aspirated and sent as pelvic urine C&S. Stone fragments are collected to be proces0sed for C&S. The data collected were divided into 3 main groups, that is MSU C&S, pelvic urine C&S and stone C&S. RESULTS : A total of 83 patients were included in the study, of this MSU C&S was positive in 9/83 (10.8% patients, Pelvic C&S in 10 /73 (13.7% patients and Stone C&S in 25/83 (30.1% patients. Out of 25 cases of stone culture positive patients 17 patients develope d Systemic Inflammatory Response Syndrome (SIRS but only 2 patients developed SIRS in MSU C & S positive patients. CONCLUSIONS: The results of our study suggest that positive stone C&S is the better predictor of potential urosepsis than MSU. Stone cultur e is available only after surgery but appears to be the best guide for antibiotic therapy in case of sepsis. So the routine collection of stone for C&S will be beneficial

  12. A correlative optical microscopy and scanning electron microscopy approach to locating nanoparticles in brain tumors.

    Science.gov (United States)

    Kempen, Paul J; Kircher, Moritz F; de la Zerda, Adam; Zavaleta, Cristina L; Jokerst, Jesse V; Mellinghoff, Ingo K; Gambhir, Sanjiv S; Sinclair, Robert

    2015-01-01

    The growing use of nanoparticles in biomedical applications, including cancer diagnosis and treatment, demands the capability to exactly locate them within complex biological systems. In this work a correlative optical and scanning electron microscopy technique was developed to locate and observe multi-modal gold core nanoparticle accumulation in brain tumor models. Entire brain sections from mice containing orthotopic brain tumors injected intravenously with nanoparticles were imaged using both optical microscopy to identify the brain tumor, and scanning electron microscopy to identify the individual nanoparticles. Gold-based nanoparticles were readily identified in the scanning electron microscope using backscattered electron imaging as bright spots against a darker background. This information was then correlated to determine the exact location of the nanoparticles within the brain tissue. The nanoparticles were located only in areas that contained tumor cells, and not in the surrounding healthy brain tissue. This correlative technique provides a powerful method to relate the macro- and micro-scale features visible in light microscopy with the nanoscale features resolvable in scanning electron microscopy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  14. Quantitation of products from riboflavin in rat urine

    International Nuclear Information System (INIS)

    Chastain, J.L.; McCormick, D.B.

    1986-01-01

    When [2- 14 C] riboflavin is injected i.p. into rats, the excreted vitamin in urine and feces has been shown to be the intact vitamin with trace amounts of lumichrome and lumiflavin. Recent findings with 14 C-riboflavin fed to rats indicated higher levels of riboflavin catabolites in urine, e.g., 7- and 8-carboxylumichromes. The authors have determined catabolites in urine from male rats fed 0, 2, and 6 μg riboflavin/g diet/day for six weeks. Two rats from each group were placed weekly in metabolic cages, and urine was collected for 24 hours. On the fourth week, a third animal from each group received an i.p. injection of 14 C-riboflavin and the urine was collected for 48 hours. Urine samples were extracted with phenol for flavin components and with chloroform for derivatives of lumichrome and lumiflavin. Riboflavin was the predominant flavin excreted by all diet groups with trace amounts of coenzymes and 7- and 8-hydroxymethylriboflavin. Riboflavin accounted for 85% of all the radioactivity recovered from the deficient and sufficient rats and 90% in rats fed excess. Lumichrome-type compounds including carboxylumichromes accounted for only a few % of recovered radioactivity. Thus, these components are primarily a product of intestinal microfloral degradation rather than significant tissue catabolites of riboflavin

  15. Comparison of urine analysis using manual and sedimentation methods.

    Science.gov (United States)

    Kurup, R; Leich, M

    2012-06-01

    Microscopic examination of urine sediment is an essential part in the evaluation of renal and urinary tract diseases. Traditionally, urine sediments are assessed by microscopic examination of centrifuged urine. However the current method used by the Georgetown Public Hospital Corporation Medical Laboratory involves uncentrifuged urine. To encourage high level of care, the results provided to the physician must be accurate and reliable for proper diagnosis. The aim of this study is to determine whether the centrifuge method is more clinically significant than the uncentrifuged method. In this study, a comparison between the results obtained from centrifuged and uncentrifuged methods were performed. A total of 167 urine samples were randomly collected and analysed during the period April-May 2010 at the Medical Laboratory, Georgetown Public Hospital Corporation. The urine samples were first analysed microscopically by the uncentrifuged, and then by the centrifuged method. The results obtained from both methods were recorded in a log book. These results were then entered into a database created in Microsoft Excel, and analysed for differences and similarities using this application. Analysis was further done in SPSS software to compare the results using Pearson ' correlation. When compared using Pearson's correlation coefficient analysis, both methods showed a good correlation between urinary sediments with the exception of white bloods cells. The centrifuged method had a slightly higher identification rate for all of the parameters. There is substantial agreement between the centrifuged and uncentrifuged methods. However the uncentrifuged method provides for a rapid turnaround time.

  16. Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ziqiang [Iowa State Univ., Ames, IA (United States)

    1999-12-10

    Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based on monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10-8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.

  17. Microscopy system of atomic force based on a digital optical reading unit and a buzzer-scanner; Sistema de microscopia de fuerza atomica basada en una unidad de lectura optica digital y un escaner-zumbador

    Energy Technology Data Exchange (ETDEWEB)

    Dabirian, R.; Loza M, D. [Universidad de las Fuerzas Armadas-ESPE, Departamento de Ciencias de la Energia y Mecanica, Sangolqui (Ecuador); Wang, W. M.; Hwu, E. T., E-mail: whoand@gmail.com [Academia Sinica, Institute of Physics, Taipei, 11529 Taiwan (China)

    2015-07-01

    An astigmatic detection system (Ads) based on a compact disk/digital-versatile-disk (Cd-DVD) astigmatic optical pickup unit is presented. It can achieve a resolution better than 0.3 nm in detection of the vertical displacement and is able to detect the two-dimensional angular tilt of the object surface. Furthermore, a novel scanner design actuated by piezoelectric disk buzzers is presented. The scanner is composed of a quad-rod actuation structure and several piezoelectric disks. It can be driven directly with low-voltage and low-current sources, such as analogue outputs of a data acquisition card and enables a sufficient scanning range of up to μm. In addition, an economic, high-performance streamlined atomic force microscopy (AFM) was constructed, using the buzzer-scanner to move the sample relative to the probe, and using a Cd/DVD optical pickup unit to detect the mechanical resonance of a micro fabricated cantilever. The performance of the AFM is evaluated. The high sensitivity and high bandwidth of the detection system makes the equipment suitable for characterizing nano scale elements. An AFM using our detection system for detecting the deflection of micro fabricated cantilevers can resolve individual atomic steps on graphite surfaces. (Author)

  18. Video-rate resonant scanning multiphoton microscopy

    Science.gov (United States)

    Kirkpatrick, Nathaniel D.; Chung, Euiheon; Cook, Daniel C.; Han, Xiaoxing; Gruionu, Gabriel; Liao, Shan; Munn, Lance L.; Padera, Timothy P.; Fukumura, Dai; Jain, Rakesh K.

    2013-01-01

    The abnormal tumor microenvironment fuels tumor progression, metastasis, immune suppression, and treatment resistance. Over last several decades, developments in and applications of intravital microscopy have provided unprecedented insights into the dynamics of the tumor microenvironment. In particular, intravital multiphoton microscopy has revealed the abnormal structure and function of tumor-associated blood and lymphatic vessels, the role of aberrant tumor matrix in drug delivery, invasion and metastasis of tumor cells, the dynamics of immune cell trafficking to and within tumors, and gene expression in tumors. However, traditional multiphoton microscopy suffers from inherently slow imaging rates—only a few frames per second, thus unable to capture more rapid events such as blood flow, lymphatic flow, and cell movement within vessels. Here, we report the development and implementation of a video-rate multiphoton microscope (VR-MPLSM) based on resonant galvanometer mirror scanning that is capable of recording at 30 frames per second and acquiring intravital multispectral images. We show that the design of the system can be readily implemented and is adaptable to various experimental models. As examples, we demonstrate the utility of the system to directly measure flow within tumors, capture metastatic cancer cells moving within the brain vasculature and cells in lymphatic vessels, and image acute responses to changes in a vascular network. VR-MPLSM thus has the potential to further advance intravital imaging and provide new insight into the biology of the tumor microenvironment. PMID:24353926

  19. Determination of uranium in urine - measurement of isotope ratios and quantification by use of inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Krystek, P.; Ritsema, R.

    2002-01-01

    For analysis of uranium in urine determination of the isotope ratio and quantification were investigated by high-resolution inductively coupled plasma mass spectrometry (HR ICP-MS). The instrument used (ThermoFinniganMAT ELEMENT2) is a single-collector MS and, therefore, a stable sample-introduction system was chosen. The methodical set-up was optimized to achieve the best precision for both the isotope ratio and the total uranium concentration in the urine matrix.Three spiked urine samples from an European interlaboratory comparison were analyzed to determine the 235 U/ 238 U isotope ratio. The ratio was found to be in the range 0.002116 to 0.007222, the latter being the natural uranium isotope ratio. The first ratio indicates the abundance of depleted uranium.The effect of storage conditions and the stability for the matrix urine were investigated by using ''real-life'' urine samples from unexposed persons in the Netherlands. For samples stored under refrigeration and acidified the results (range 0.8 to 5.3 ng L -1 U) were in the normal fluctuation range whereas a decrease in uranium concentration was observed for samples stored at room temperature without acidification. (orig.)

  20. Selenium speciation in urine by ion-pairing chromatography with perfluorinated carboxylic acids and ICP-MS detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Bendahl, L.; Sidenius, U.

    2002-01-01

    Five aqueous standards, selenomethionine (SeMet), methylselenomethionine (MeSeMet), methylselenocysteine (MeSeCys), selenogammaaminobutyric acid (SeGaba) and the trimethylselenonium ion (TMSe), were separated in ion-pairing chromatographic systems based on perfluorinated carboxylic acids in metha...... were major compounds in urine samples-even after massive consumption of selenium-containing supplements. The selenium species in the urine samples showed a limited stability, as they changed during storage at +4 degreesC as well as -18 degreesC...... of between 2.3 and 5.1 pg. Urine samples from different individuals before and during supplementation with selenomethionine were analysed. Several species were separated in the different urine samples. A major component eluting at the beginning of the chromatogram was predominant in many samples, especially...... after selenium consumption. This species was not identified and solid phase extraction experiments suggested that it was neutral. When different urine samples were spiked with the available standards, co-elution of species with TMSe, MeSeMet or SeMet was observed in some samples. None of these species...