WorldWideScience

Sample records for upper trapezius trigger

  1. Skin Resistivity Value of Upper Trapezius Latent Trigger Points

    Directory of Open Access Journals (Sweden)

    Elżbieta Skorupska

    2015-01-01

    Full Text Available Introduction. The skin resistivity (SkR measurement is commonly recommended for acupoints measurement, but for trigger points (TrPs only one study is available. The purpose of the study was to evaluate SkR for latent TrPs compared to non-TrPs and the surrounding tissue. Material and Methods. Forty-two healthy volunteers with unilateral latent upper trapezius TrPs (12 men, 30 women aged 21–23 (mean age: 22.1 ± 0.6 y participated in the study. Keithley electrometer 610B was used for measuring SkR (Ag/AgCl self-adhesive, disposable ground electrode: 30 mm diameter. SkR was measured for latent TrPs and compared to opposite non-TrPs sites and the surrounding tissue. Results. The SkR decrease of TrPs-positive sites as compared to TrPs-negative sites and the surrounding tissue was confirmed. However, no statistically significant difference in the SkR value occurred when all data were analyzed. The same was confirmed after gender division and for TrPs-positive subjects examined for referred pain and twitch response presence. Conclusion. SkR reactive changes at latent TrPs are possible but the results were not consistent with the previous study. Thus, caution in applying SkR to latent TrPs isolation is recommended and its clinical use should not be encouraged yet. Further studies, especially on active TrPs, are yet required.

  2. EFFECTIVENESS OF INTEGRATED NEUROMUSCULAR INHIBITORY TECHNIQUE (INIT WITH SPECIFIC STRENGTH TRAINING EXERCISES IN SUBJECTS WITH UPPER TRAPEZIUS TRIGGER POINTS

    Directory of Open Access Journals (Sweden)

    B. Jyothirmai

    2015-10-01

    Full Text Available Background: Upper trapezius trigger points is a common cause for neck pain, decreased cervical range of motion and functional activities. The purpose of the study was to evaluate the effectiveness of integrated neuromuscular inhibitory technique (INIT along with specific strength training exercises in reducing pain, improving ROM and functional activities in subjects with upper trapezius trigger point. Methods: Thirty subjects were diagnosed with upper trapezius trigger points were included in the study. These patients were randomly allocated to intervention group (n=15, which underwent a 4- weeks training program of INIT along with specific strength training & control group (n=15 that received INIT alone. The outcome measures were taken before and after treatment. Outcomes were measured by visual analogue scale, cervical range of motion and neck disability index. Within the groups VAS, NDI, and cervical lateral flexion and rotation showed significant change in the mean value. The comparison of pre and post VAS in experimental group and control group showed a significant change in the experimental group .Paired sample t- test was used to analyze changes from before and after intervention programmed. Results: There is a statistically significant (p<0.00 improvement in both variables from baseline to 4th week in experimental group and control group but compared to control group, experimental group shows highly significant values in all parameters. Conclusion: INIT along with specific strength training is proved to be effective in reducing pain, decreasing disability and improving range of motion in individuals with upper trapezius trigger points.

  3. Predictors of upper trapezius pain with myofascial trigger points in food service workers

    Science.gov (United States)

    Hwang, Ui-Jae; Kwon, Oh-Yun; Yi, Chung-Hwi; Jeon, Hye-Seon; Weon, Jong-Hyuck; Ha, Sung-Min

    2017-01-01

    Abstract Shoulder pain occurs commonly in food service workers (FSWs) who repetitively perform motions of the upper limbs. Myofascial trigger points (MTrPs) on the upper trapezius (UT) are among the most common musculoskeletal shoulder pain syndromes. This study determined the psychological, posture, mobility, and strength factors associated with pain severity in FSWs with UT pain due to MTrPs. In this cross-sectional study, we measured 17 variables in 163 FSWs with UT pain due to MTrPs: a visual analog scale (VAS) pain score, age, sex, Borg rating of perceived exertion (BRPE) scale, beck depression inventory, forward head posture angle, rounded shoulder angle (RSA), shoulder slope angle, scapular downward rotation ratio, cervical lateral-bending side difference angle, cervical rotation side difference angle, glenohumeral internal rotation angle, shoulder horizontal adduction angle, serratus anterior (SA) strength, lower trapezius (LT) strength, bicep strength, and glenohumeral external rotator strength, in 163 FSWs with UT pain due to MTrPs. The model for factors influencing UT pain with MTrPs included SA strength, age, BRPE, LT strength, and RSA as predictor variables that accounted for 68.7% of the variance in VAS (P < .001) in multiple regression models with a stepwise selection procedure. The following were independent variables influencing the VAS in the order of standardized coefficients: SA strength (β = −0.380), age (β = 0.287), BRPE (β = 0.239), LT strength (β = −0.195), and RSA (β = 0.125). SA strength, age, BRPE, LT strength, and RSA variables should be considered when evaluating and intervening in UT pain with MTrPs in FSWs. PMID:28658117

  4. Predictors of upper trapezius pain with myofascial trigger points in food service workers: The STROBE study.

    Science.gov (United States)

    Hwang, Ui-Jae; Kwon, Oh-Yun; Yi, Chung-Hwi; Jeon, Hye-Seon; Weon, Jong-Hyuck; Ha, Sung-Min

    2017-06-01

    Shoulder pain occurs commonly in food service workers (FSWs) who repetitively perform motions of the upper limbs. Myofascial trigger points (MTrPs) on the upper trapezius (UT) are among the most common musculoskeletal shoulder pain syndromes. This study determined the psychological, posture, mobility, and strength factors associated with pain severity in FSWs with UT pain due to MTrPs.In this cross-sectional study, we measured 17 variables in 163 FSWs with UT pain due to MTrPs: a visual analog scale (VAS) pain score, age, sex, Borg rating of perceived exertion (BRPE) scale, beck depression inventory, forward head posture angle, rounded shoulder angle (RSA), shoulder slope angle, scapular downward rotation ratio, cervical lateral-bending side difference angle, cervical rotation side difference angle, glenohumeral internal rotation angle, shoulder horizontal adduction angle, serratus anterior (SA) strength, lower trapezius (LT) strength, bicep strength, and glenohumeral external rotator strength, in 163 FSWs with UT pain due to MTrPs.The model for factors influencing UT pain with MTrPs included SA strength, age, BRPE, LT strength, and RSA as predictor variables that accounted for 68.7% of the variance in VAS (P < .001) in multiple regression models with a stepwise selection procedure. The following were independent variables influencing the VAS in the order of standardized coefficients: SA strength (β = -0.380), age (β = 0.287), BRPE (β = 0.239), LT strength (β = -0.195), and RSA (β = 0.125).SA strength, age, BRPE, LT strength, and RSA variables should be considered when evaluating and intervening in UT pain with MTrPs in FSWs.

  5. The Effect of Dry Needling Compared With Ischemic Pressure on Pain Intensity on Active Trigger Point in Upper Trapezius Muscle

    Directory of Open Access Journals (Sweden)

    Maryam Ziaeifar

    2013-07-01

    Full Text Available Objective: Myofascial trigger point is one of the most common causes of musculoskeletal pain and disorders. Myofascial trigger point in upper trapezius has been reported as a frequent symptom in patients with neck and thoracic pain. The purpose of this study was to investigate the effect of dry needling compared with ischemic pressure on active trigger point in upper trapezius muscle. Materials & Methods: 32 women with active myofascial trigger point in upper trapezius muscle participated in this randomized clinical trial (RCT study. The subjects were randomly assigned into two groups: dry needling (N=15 and ischemic pressure (N=17. The visual analogue scale (VAS was used to assess the pain intensity before and after treatment in both groups. Paired t-test was used to determine any significant difference in pain intensity after treatment sessions compared with pre-treatment score in control and experimental group. Analysis of Covariance (ANCOVA was calculated to determine the significance of differences between the control and experimental groups in post-test scores, with pre-treatment scores used as covariates in the analysis. Results: Statistical analysis (paired t-test revealed significant decrease in pain intensity after treatment sessions in control and experimental group (P=0.00 compared with pre-treatment score. In the ANCOVA, controlling for pre-test scores, no significant difference was found between the two groups (P=0.8. Conclusion: It seems that that both dry needling and ischemic pressure are effective in improvement in the pain intensity in subjects with myofascial trigger points. However, dry needling can be used by clinicians and therapist in physiotherapy clinics.

  6. Remote Effect of Lower Limb Acupuncture on Latent Myofascial Trigger Point of Upper Trapezius Muscle: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Kai-Hua Chen

    2013-01-01

    Full Text Available Objectives. To demonstrate the use of acupuncture in the lower limbs to treat myofascial pain of the upper trapezius muscles via a remote effect. Methods. Five adults with latent myofascial trigger points (MTrPs of bilateral upper trapezius muscles received acupuncture at Weizhong (UB40 and Yanglingquan (GB34 points in the lower limbs. Modified acupuncture was applied at these points on a randomly selected ipsilateral lower limb (experimental side versus sham needling on the contralateral lower limb (control side in each subject. Each subject received two treatments within a one-week interval. To evaluate the remote effect of acupuncture, the range of motion (ROM upon bending the contralateral side of the cervical spine was assessed before and after each treatment. Results. There was significant improvement in cervical ROM after the second treatment (P=0.03 in the experimental group, and the increased ROM on the modified acupuncture side was greater compared to the sham needling side (P=0.036. Conclusions. A remote effect of acupuncture was demonstrated in this pilot study. Using modified acupuncture needling at remote acupuncture points in the ipsilateral lower limb, our treatments released tightness due to latent MTrPs of the upper trapezius muscle.

  7. Remote Effect of Lower Limb Acupuncture on Latent Myofascial Trigger Point of Upper Trapezius Muscle: A Pilot Study

    Science.gov (United States)

    Chen, Kai-Hua; Hsiao, Kuang-Yu; Lin, Chu-Hsu; Chang, Wen-Ming; Hsu, Hung-Chih; Hsieh, Wei-Chi

    2013-01-01

    Objectives. To demonstrate the use of acupuncture in the lower limbs to treat myofascial pain of the upper trapezius muscles via a remote effect. Methods. Five adults with latent myofascial trigger points (MTrPs) of bilateral upper trapezius muscles received acupuncture at Weizhong (UB40) and Yanglingquan (GB34) points in the lower limbs. Modified acupuncture was applied at these points on a randomly selected ipsilateral lower limb (experimental side) versus sham needling on the contralateral lower limb (control side) in each subject. Each subject received two treatments within a one-week interval. To evaluate the remote effect of acupuncture, the range of motion (ROM) upon bending the contralateral side of the cervical spine was assessed before and after each treatment. Results. There was significant improvement in cervical ROM after the second treatment (P = 0.03) in the experimental group, and the increased ROM on the modified acupuncture side was greater compared to the sham needling side (P = 0.036). Conclusions. A remote effect of acupuncture was demonstrated in this pilot study. Using modified acupuncture needling at remote acupuncture points in the ipsilateral lower limb, our treatments released tightness due to latent MTrPs of the upper trapezius muscle. PMID:23710218

  8. The Effects of Active Trigger Point of Upper Trapezius Muscle on Its Electromyography Activity and Maximal Isometric Contraction Force during Scapular Plane Elevation (Scaption

    Directory of Open Access Journals (Sweden)

    Zahra Mohammadi

    2014-01-01

    Full Text Available Objective: Trigger points may result in referral pain of their close areas. Recent evidence suggests that latent trigger points although they are not sensitive enough to cause pain, can interfere with the normal muscle function. These myofascial trigger points are estimated as an electro-physiological phenomenon. However, there are a few studies which investigated the effect of these points on the muscle activity. Muscle activity is a determinant factor in injuries which may cause or worsen shoulder-neck pain. The aim of the study was to evaluate upper trapezius muscle activity and delay time at the presence of active trigger point during scapular plane elevation (scaption. Materials & Methods: In a case-control comparative study in spring 2012, Seventeen women with active trigger points (mean age 26.76 y and 17 healthy women (mean age 26.18 y in bio-mechanic laboratory of University of Social Welfare and Rehabilitation sciences (USWR participated in the study. Using surface EMG, the amplitude of muscle activity and the onset time of upper trapezius during scaption, were recorded and analyzed. Results: The maximum amplitude of the upper trapezius muscle activity (during maximal voluntary isometric contraction of 90°scaption in patients showed significant decrease in comparison with the healthy subjects (P=0.01.Also, the onset time of upper trapezius muscle activation time in the patient group was significantly delayed in comparison to the healthy group (P=0.04. Conclusion: At the presence of trigger points in Upper trapezius muscle, muscle activation pattern changes trigger points can change the amplitude and timing of muscle activity and may consequently lead to abnormal patterns of motion of the shoulder girdle. These findings can be used in the prevention and treatment of shoulder disorders.

  9. Friction massage versus kinesiotaping for short-term management of latent trigger points in the upper trapezius: a randomized controlled trial.

    Science.gov (United States)

    Mohamadi, Marzieh; Piroozi, Soraya; Rashidi, Iman; Hosseinifard, Saeed

    2017-01-01

    Latent trigger points in the upper trapezius muscle may disrupt muscle movement patterns and cause problems such as cramping and decreased muscle strength. Because latent trigger points may spontaneously become active trigger points, they should be addressed and treated to prevent further problems. In this study we compared the short-term effect of kinesiotaping versus friction massage on latent trigger points in the upper trapezius muscle. Fifty-eight male students enrolled with a stratified sampling method participated in this single-blind randomized clinical trial (Registration ID: IRCT2016080126674N3) in 2016. Pressure pain threshold was recorded with a pressure algometer and grip strength was recorded with a Collin dynamometer. The participants were randomly assigned to two different treatment groups: kinesiotape or friction massage. Friction massage was performed daily for 3 sessions and kinesiotape was used for 72 h. One hour after the last session of friction massage or removal of the kinesiotape, pressure pain threshold and grip strength were evaluated again. Pressure pain threshold decreased significantly after both friction massage (2.66 ± 0.89 to 2.25 ± 0.76; P  = 0.02) and kinesiotaping (2.00 ± 0.74 to 1.71 ± 0.65; P  = 0.01). Grip strength increased significantly after friction massage (40.78 ± 9.55 to 42.17 ± 10.68; P  = 0.03); however there was no significant change in the kinesiotape group (39.72 ± 6.42 to 40.65 ± 7.3; P  = 0.197). There were no significant differences in pressure pain threshold (2.10 ± 0.11 & 1.87 ± 0.11; P  = 0.66) or grip strength (42.17 ± 10.68 & 40.65 ± 7.3; P  = 0.53) between the two study groups. Friction massage and kinesiotaping had identical short-term effects on latent trigger points in the upper trapezius. Three sessions of either of these two interventions did not improve latent trigger points. Registration ID in IRCT: IRCT2016080126674N3.

  10. Skeletal muscle contractility, self-reported pain and tissue sensitivity in females with neck/shoulder pain and upper Trapezius myofascial trigger points - a randomized intervention study

    DEFF Research Database (Denmark)

    Myburgh, Corrie; Hartvigsen, Jan; Aagaard, Per

    2012-01-01

    . METHODS: Seventy-seven female office workers (25-46yrs) with and without neck/shoulder pain were observed with respect to self-reported pain (NRS-101), pressure-pain threshold (PPT), maximum voluntary contraction (Fmax) and rate of force development (RFD) at baseline (pre-intervention), immediately post...... or intervention (p=0.001). CONCLUSIONS: In selected female neck/shoulder pain sufferers, maximum voluntary contraction and rapid force generation of the upper Trapezius was not influenced by clinically relevant self-reported pain or the presence of diagnostically relevant MFTrPs. Dry needling, deep or superficial......, did not affect measured functional outcomes over the 48-hour observation period. DOMS affected participants uniformly irrespective of pain, MFTrP status or intervention type and therefore is like to act as a modifier.Trial registrationClinical Trials.gov- NCT01710735Significance and Innovations...

  11. Adaptations of upper trapezius muscle activity during sustained contractions in women with fibromyalgia

    DEFF Research Database (Denmark)

    Falla, Deborah Lorraine; Andersen, Helle; Danneskiold-Samsøe, Bente

    2010-01-01

    The study compared the distribution of electromyographic (EMG) signal amplitude in the upper trapezius muscle in 10 women with fibromyalgia and in 10 healthy women before and after experimentally-induced muscle pain. Surface EMG signals were recorded over the right upper trapezius muscle with a 10...

  12. Effect of One Carpet Weaving Workstation on Upper Trapezius Fatigue

    Directory of Open Access Journals (Sweden)

    Neda Mahdavi

    2016-03-01

    Full Text Available Introduction: This study aimed to investigate the effect of carpet weaving at a proposed workstation on Upper Trapezius (UTr fatigue during a task cycle. Fatigue in the shoulder is one of the most important precursors for upper limb musculoskeletal disorders. One of the most prevalent musculoskeletal disorders between carpet weavers is disorder of the shoulder region. Methods: This cross-sectional study, included eight females and three males. During an 80-minute cycle of carpet weaving, Electromyography (EMG signals of right and left UTr were recorded by the surface EMG, continuously. After raw signals were processed, MPF and RMS were considered as EMG amplitude and frequency parameters. Time series model and JASA methods were used to assess and classify the EMG parameter changes during the working time. Results: According to the JASA method, 58%, 16%, 8% and 8% of the participants experienced fatigue, force increase, force decrease and recovery, respectively in the right UTr. Also, 50%, 25%, 8% and 16% of the participants experienced fatigue, force increase, force decrease and recovery, respectively in the left UTr. Conclusions: For the major portion of the weavers, dominant status in Left and right UTr was fatigue, at the proposed workstation during a carpet weaving task cycle. The results of the study provide detailed information for optimal design of workstations. Further studies should focus on fatigue in various muscles and time periods for designing an appropriate and ergonomics carpet weaving workstation

  13. Influence of Gluteus Maximus Inhibition on Upper Trapezius Overactivity in Chronic Mechanical Neck Pain with Radiculopathy

    Directory of Open Access Journals (Sweden)

    Ghada Mohamed Koura

    2017-03-01

    Full Text Available Background: Mechanical neck pain is the most common type of neck pain and commonly to accompany with radiculopathy. Patients of neck pain exhibit greater activation of accessory muscles, (sternocleidomastoid, anterior scalene, and upper trapezius muscles and may also show changed patterns of motor control of other postural muscles as pelvic muscles for reducing activation of painful muscles of neck. Aim of the study: To determine if there is an association between gluteus maximus inhibition and overactivity of upper fibres of trapezius in patients with chronic mechanical neck pain with radiculopathy. Materials and Methods: Forty female patients participated in this study diagnosed as chronic mechanical neck pain with radiculopathy. Amplitude and onset of muscle activation were assessed by using the surface electromyography (EMG during prone hip extension test. Results: The results of this study demonstrated that there is no correlation between the amplitude of EMG activity of right and left gluteus maximus and the amplitude of EMG activity of right and left upper trapezius (P<0.05. Conclusion: It can be concluded that the overactivity of the upper trapezius muscle in patients with chronic mechanical neck pain with radiculopathy is not related to the inhibition of the gluteus maximus muscle during prone hip extension test.

  14. Protocol: Testing the Relevance of Acupuncture Theory in the Treatment of Myofascial Pain in the Upper Trapezius Muscle.

    Science.gov (United States)

    Elsdon, Dale S; Spanswick, Selina; Zaslawski, Chris; Meier, Peter C

    2017-01-01

    A protocol for a prospective single-blind parallel four-arm randomized placebo-controlled trial with repeated measures was designed to test the effects of various acupuncture methods compared with sham. Eighty self-selected participants with myofascial pain in the upper trapezius muscle were randomized into four groups. Group 1 received acupuncture to a myofascial trigger point (MTrP) in the upper trapezius. Group 2 received acupuncture to the MTrP in addition to relevant distal points. Group 3 received acupuncture to the relevant distal points only. Group 4 received a sham treatment to both the MTrP and distal points using a deactivated acupuncture laser device. Treatment was applied four times within 2 weeks with outcomes measured throughout the trial and at 2 weeks and 4 weeks posttreatment. Outcome measurements were a 100-mm visual analog pain scale, SF-36, pressure pain threshold, Neck Disability Index, the Upper Extremity Functional Index, lateral flexion in the neck, McGill Pain Questionnaire, Massachusetts General Hospital Acupuncture Sensation Scale, Working Alliance Inventory (short form), and the Credibility Expectance Questionnaire. Two-way analysis of variance (ANOVA) with repeated measures were used to assess the differences between groups. Copyright © 2017 Medical Association of Pharmacopuncture Institute. Published by Elsevier B.V. All rights reserved.

  15. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    Science.gov (United States)

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Preferential distribution of nociceptive input to motoneurons with muscle units in the cranial portion of the upper trapezius muscle.

    Science.gov (United States)

    Dideriksen, Jakob L; Holobar, Ales; Falla, Deborah

    2016-08-01

    Pain is associated with changes in the neural drive to muscles. For the upper trapezius muscle, surface electromyography (EMG) recordings have indicated that acute noxious stimulation in either the cranial or the caudal region of the muscle leads to a relative decrease in muscle activity in the cranial region. It is, however, not known if this adaption reflects different recruitment thresholds of the upper trapezius motor units in the cranial and caudal region or a nonuniform nociceptive input to the motor units of both regions. This study investigated these potential mechanisms by direct motor unit identification. Motor unit activity was investigated with high-density surface EMG signals recorded from the upper trapezius muscle of 12 healthy volunteers during baseline, control (intramuscular injection of isotonic saline), and painful (hypertonic saline) conditions. The EMG was decomposed into individual motor unit spike trains. Motor unit discharge rates decreased significantly from control to pain conditions by 4.0 ± 3.6 pulses/s (pps) in the cranial region but not in the caudal region (1.4 ± 2.8 pps; not significant). These changes were compatible with variations in the synaptic input to the motoneurons of the two regions. These adjustments were observed, irrespective of the location of noxious stimulation. These results strongly indicate that the nociceptive synaptic input is distributed in a nonuniform way across regions of the upper trapezius muscle. Copyright © 2016 the American Physiological Society.

  17. The change in spatial distribution of upper trapezius muscle activity is correlated to contraction duration.

    Science.gov (United States)

    Farina, Dario; Leclerc, Frédéric; Arendt-Nielsen, Lars; Buttelli, Olivier; Madeleine, Pascal

    2008-02-01

    The aim of the study was to confirm the hypothesis that the longer a contraction is sustained, the larger are the changes in the spatial distribution of muscle activity. For this purpose, surface electromyographic (EMG) signals were recorded with a 13 x 5 grid of electrodes from the upper trapezius muscle of 11 healthy male subjects during static contractions with shoulders 90 degrees abducted until endurance. The entropy (degree of uniformity) and center of gravity of the EMG root mean square map were computed to assess spatial inhomogeneity in muscle activation and changes over time in EMG amplitude spatial distribution. At the endurance time, entropy decreased (mean+/-SD, percent change 2.0+/-1.6%; Pgrid) root mean square was positively correlated with the shift in the center of gravity (R(2)=0.51, P<0.05). Moreover, the shift in the center of gravity was negatively correlated to both initial and final (at the endurance) entropy (R(2)=0.54 and R(2)=0.56, respectively; P<0.01 in both cases), indicating that subjects with less uniform root mean square maps had larger shift of the center of gravity over time. The spatial changes in root mean square EMG were likely due to spatially-dependent changes in motor unit activation during the sustained contraction. It was concluded that the changes in spatial muscle activity distribution play a role in the ability to maintain a static contraction.

  18. Comparison of the electrical activity in upper trapezius and wrist extensor muscles during two typewriting conditions

    Directory of Open Access Journals (Sweden)

    João Carlos Comel

    Full Text Available Introduction The proper use of the position of the arm and wrist while typing may reduce muscle overload and prevent musculoskeletal disorders.Objective To evaluate the electromyographic activity of upper trapezius and wrist extensor muscles during two typewriting conditions.Materials and methods : Six healthy females (Xage = 42 years,SD= 10, (Xheight = 1.65m, SD = 0.05 and (Xweight = 71kg, SD = 16 participated in this study. The task was performed with a newly developed arm support and without the support. A perceived exertion scale was used with all subjects. An ANOVA with repeated measures was used to verify differences in perceived exertion and root mean square (RMS.Results There were no statistically significant differences for the RMS between the typewriting tasks. The condition without arm support presented a significantly greater mean velocity and amount of words typed (P= 0.02; P= 0.03 and there was a significant difference in perceived exertion during the condition without arm support (P= 0.03. Electromyographic activity did not present differences.Conclusion The muscle electrical activity was not altered regardless the arm support and occurred the improvement of the perceived exertion after 10 minutes of typing without support. Long-term studies are needed.

  19. Children with migraine: Provocation of headache via pressure to myofascial trigger points in the trapezius muscle? - A prospective controlled observational study.

    Science.gov (United States)

    Landgraf, M N; Biebl, J T; Langhagen, T; Hannibal, I; Eggert, T; Vill, K; Gerstl, L; Albers, L; von Kries, R; Straube, A; Heinen, F

    2018-02-01

    The objective was to evaluate a supposed clinical interdependency of myofascial trigger points and migraine in children. Such interdependency would support an interaction of spinal and trigeminal afferences in the trigemino-cervical complex as a contributing factor in migraine. Children ≤18 years with the confirmed diagnosis of migraine were prospectively investigated. Comprehensive data on medical history, clinical neurological and psychological status were gathered. Trigger points in the trapezius muscle were identified by palpation and the threshold of pressure pain at these points was measured. Manual pressure was applied to the trigger points, and the occurrence and duration of induced headache were recorded. At a second consultation (4 weeks after the first), manual pressure with the detected pressure threshold was applied to non-trigger points within the same trapezius muscle (control). Headache and related parameters were again recorded and compared to the results of the first consultation. A total of 13 girls and 13 boys with migraine and a median age of 14.5 (Range 6.3-17.8) years took part in the study. Manual pressure to trigger points in the trapezius muscle led to lasting headache after termination of the manual pressure in 13 patients while no patient experienced headache when manual pressure was applied to non-trigger points at the control visit (p complex, especially in adolescents. In children with migraine headache can often be induced by pressure to myofascial trigger points, but not by pressure to non-trigger points in the trapezius muscle. This supports the hypothesis of a trigemino-cervical-complex in the pathophysiology of migraine, which might have implications for innovative therapies in children with migraine. © 2017 European Pain Federation - EFIC®.

  20. Active biofeedback changes the spatial distribution of upper trapezius muscle activity during computer work

    DEFF Research Database (Denmark)

    Samani, Afshin; Holtermann, Andreas; Søgaard, Karen

    2010-01-01

    The aim of this study was to investigate the spatio-temporal effects of advanced biofeedback by inducing active and passive pauses on the trapezius activity pattern using high-density surface electromyography (HD-EMG). Thirteen healthy male subjects performed computer work with superimposed...... benefit of superimposed muscle contraction in relation to the spatial organization of muscle activity during computer work....

  1. Increased Upper Trapezius Muscle Stiffness in Overhead Athletes with Rotator Cuff Tendinopathy.

    Directory of Open Access Journals (Sweden)

    Hio Teng Leong

    Full Text Available Although excessive tension of the upper trapezius (UT is thought to contribute to rotator cuff tendinopathy, no study examined UT tension in athletes with and without rotator cuff tendinopathy. Here we used UT shear modulus measured using ultrasound shear wave elastography as an index of muscle stiffness/tension. The aims of this study were twofold: 1 to determine whether the UT muscle shear modulus is altered in athletes with rotator cuff tendinopathy compared to asymptomatic athletes, and 2 to detect optimal cut-off points of UT shear modulus in identifying athletes with rotator cuff tendinopathy. Forty-three male volleyball players (17 asymptomatic and 26 with rotator cuff tendinopathy, mean age = 22.9±3.5 years participated in the study. UT shear modulus was quantified during active arm holding at 30° and 60° of shoulder abduction and passive arm positioning at 0°, 30° and 60° of shoulder abduction. During the active tasks, the UT shear modulus was higher in athletes with rotator cuff tendinopathy than the asymptomatic athletes (p = 0.002, regardless the arm position. During the passive tasks, athletes with rotator cuff tendinopathy exhibited a higher UT shear modulus than asymptomatic athletes only at 0° of shoulder abduction (13.0±2.5 kPa vs 10.2±1.8 kPa, p = 0.001. When considering the active task, an optimal cut-off shear modulus of 12.0 kPa at 30° of shoulder abduction (sensitivity = 0.84, specificity = 0.57, AUC = 0.757, p = 0.008 and 9.5 kPa at 60° of shoulder abduction (sensitivity = 0.88, specificity = 0.67, AUC = 0.816, p = 0.002 was detected. When considering the passive task at 0° of shoulder abduction, a cut-off of 12.2 kPa was found (sensitivity = 0.73, AUC = 0.817, p = 0.001. Findings from the present study show that monitoring passive and active UT muscle shear modulus may provide important information for the prevention/rehabilitation of rotator cuff tendinopathy.

  2. Motor control and cardiovascular responses during isoelectric contractions of the upper trapezius muscle: evidence for individual adaptation strategies.

    Science.gov (United States)

    Mathiassen, S E; Aminoff, T

    1997-01-01

    Ten females (25-50 years of age) performed isometric shoulder flexions, holding the right arm straight and in a horizontal position. The subjects were able to see the rectified surface electromyogram (EMG) from either one of two electrode pairs above the upper trapezius muscle and were instructed to keep its amplitude constant for 15 min while gradually unloading the arm against a support. The EMG electrodes were placed at positions representing a "cranial" and a "caudal" region of the muscle suggested previously to possess different functional properties. During the two contractions, recordings were made of: (1) EMG root mean square-amplitude and zero crossing (ZC) frequency from both electrode pairs on the trapezius as well as from the anterior part of the deltoideus, (2) supportive force, (3) heart rate (HR) and mean arterial blood pressure (MAP), and (4) perceived fatigue. The median responses during the cranial isoelectric contraction were small as compared to those reported previously in the literature: changes in exerted glenohumeral torque and ZC rate of the isoelectric EMG signal of -2.81% x min(-1) (P = 0.003) and 0.03% x min(-1) (P = 0.54), respectively, and increases in HR and MAP of 0.14 beats x min(-2) (P = 0.10) and 0.06 mmHg x min(-1) (P = 0.33), respectively. During the contraction with constant caudal EMG amplitude, the corresponding median responses were -2.51% x min(-1) (torque), 0.01% x min(-1) (ZC rate), 0.31 beats x min(-2) (HR), and 0.93 mmHg x min(-1) (MAP); P = 0.001, 0.69, 0.005, and 0.003, respectively. Considerable deviations from the "isoelectric" target amplitude were common for both contractions. Individuals differed markedly in response, and three distinct subgroups of subjects were identified using cluster analysis. These groups are suggested to represent different motor control scenarios, including differential engagement of subdivisions of the upper trapezius, alternating motor unit recruitment and, in one group, a gradual

  3. EFFECTIVENESS OF ISCHEMIC COMPRESSION ON TRAPEZIUS MYOFASCIAL TRIGGER POINTS IN NECK PAIN

    Directory of Open Access Journals (Sweden)

    Pragnya Ravichandran

    2016-04-01

    Full Text Available Background: Neck pain is a common disorder prevailing among individuals of different populations. The myofascial pain syndrome is a disorder related to myofascial trigger points. It is defined as a hyperirritable locus in skeletal muscle and that is associated with a hypersensitive palpable nodule in a taut band of muscle. Manual therapy has got a profound role in treating and ischemic compression technique has been researched widely. Thus the study intends to analyse the effectiveness of Manual Therapy (Ischemic Compression on functional outcome in neck pain. Methods: A single blinded randomized control study was conducted for subjects of sample size 30 who met the inclusion criteria and random allocation was made. The baseline parameters as like pain severity using VAS, pain pressure threshold using pressure Algometer, active cervical lateral flexion using 360 degree goniometer and disability using NDI were recorded. Study group received ischemic compression followed by myofascial stretches while the control group received ultrasonic therapy of 1.4watts/cm2. Both received Cryotherapy post session. After 2 weeks the baseline parameters were again recorded for t-test analysis. Result: There was no statistical significance between groups (p≥0.05. But active cervical lateral flexion showed improved mobility in study group and a high statistical significance within groups (p≤0.01 in relation to all parameters. Conclusion: Both ultrasonic therapy and Ischemic compression technique was found to show better improvement in pain pressure threshold and functional outcome in neck pain.

  4. Effects of electromyographic and mechanomyographic biofeedback on upper trapezius muscle activity during standardized computer work

    DEFF Research Database (Denmark)

    Madeleine, Pascal; Vedsted, Pernille; Blangsted, Anne Katrine

    2006-01-01

    The purpose of this laboratory study was to investigate the effects of surface electromyography (EMG)- and mechanomyography (MMG)-based audio and visual biofeedback during computer work. Standardized computer work was performed for 3 min with/without time constraint and biofeedback in a randomize...... alternative to EMG in ergonomics. A lowering of the trapezius muscle activity may contribute to diminish the risk of work related musculoskeletal disorders development.......The purpose of this laboratory study was to investigate the effects of surface electromyography (EMG)- and mechanomyography (MMG)-based audio and visual biofeedback during computer work. Standardized computer work was performed for 3 min with/without time constraint and biofeedback in a randomized......) values as well as the work performance in terms of number of completed graph/mouse clicks/errors, the rating of perceived exertion (RPE) and the usefulness of the biofeedback were assessed. The duration of muscle activity above the threshold was significantly lower with MMG compared with EMG as source...

  5. The Effect of Auricular and Systemic Acupuncture on the Electromyographic Activity of the Trapezius Muscle with Trigger Points—A Pilot Study

    Directory of Open Access Journals (Sweden)

    Patrícia Silva de Camargo

    2018-02-01

    Full Text Available The purpose of this study was to analyze and compare intra and intergroup the immediate effect of the auricular and LR8 systemic acupuncture on the electromyographic activity of the trapezius with the trigger points. This is an experimental clinical trial; 40 people were split in 4 distinct groups (n = 10: GI mustard seed application in the auricular acupoint; GII bilateral needle application in the LR8 acupoint; GIII combination of the techniques; GIV/Control Group mustard seed application in an acupoint not linked to the muscle tension. The EMG was used to assess the muscle contraction for 5 seconds during the resting time and during the isometric contraction time. The EMG signal was first collect without the acupuncture intervention; then both techniques were applied for 5 minutes; and the EMG was collected again right after these applications. The Shapiro-Wilk test was used, the t test was paired with the Wilcoxon test to the intragroup comparison; One-way analysis of variance test for intergroup comparison. There was no statistical difference in the intragroup comparison for the groups. The same happened to the intergroup comparison before and after application. Systemic and auricular acupuncture did not promote immediate changes in the EMG activity of the trapezius muscle in individuals with MTrPs.

  6. Selective activation of neuromuscular compartments within the human trapezius muscle

    DEFF Research Database (Denmark)

    Holtermann, A; Roeleveld, K; Mork, P J

    2009-01-01

    of the human trapezius muscle can be independently activated by voluntary command, indicating neuromuscular compartmentalization of the trapezius muscle. The independent activation of the upper and lower subdivisions of the trapezius is in accordance with the selective innervation by the fine cranial and main...... branch of the accessory nerve to the upper and lower subdivisions. These findings provide new insight into motor control characteristics, learning possibilities, and function of the clinically relevant human trapezius muscle....

  7. Whistler Triggered Upper Band Chorus Observed in Alaska

    Science.gov (United States)

    Hosseini, P.; Golkowski, M.

    2017-12-01

    VLF radiation from lightning discharges is one of several sources of energy injection into the inner magnetosphere from the Earth. Lightning discharges initially produce a broadband impulse or `sferic' but after propagation in the dispersive magnetosphere this waveform soon becomes quasi narrow band with the characteristic spectrographic form of the whistler. Most of the lightning induced VLF wave energy injected into the magnetosphere will be unducted with a k-vector which becomes increasingly oblique. Although unducted radiation is ubiquitous throughout the inner magnetosphere, it is generally of a low amplitude due to Landau damping and is not expected to produce strong nonlinear phenomena such as triggered emissions and chorus waves. However, VLF wave energy ducted or trapped in field-aligned plasma density enhancements can have relatively large amplitudes due to focusing and also linear cyclotron resonance growth. Therefore high amplitude ducted whistler waves can trigger a number of complex nonlinear phenomena. These include the triggering of VLF emissions and triggering of VLF hiss or chorus. Such phenomena are generally considered to result from nonlinear electron cyclotron phase trapping. Observation of such VLF emissions triggered by natural whistlers have been reported since the 1970s in Antarctica. We present observations of whistlers triggered upper band chorus emission from Alaska. Dispersion analyze of whistlers determine the L-shell range to be 4.5 clear frequency band gap between upper and lower band of the observed chorus emissions. The observations point to ducted chorus generation in the vicinity of the plasmapause boundary.

  8. Evaluation of the immediate effect of acupuncture on pain, cervical range of motion and electromyographic activity of the upper trapezius muscle in patients with nonspecific neck pain: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Calamita, Simone Aparecida Penimpedo; Biasotto-Gonzalez, Daniela Aparecida; De Melo, Nivea Cristina; dos Santos, Douglas Meira; de Lassa, Roberta; de Mendonça, Fabiana Sarilho; Oliveira, Claudia Santos; Amorim, César Ferreira; Gonzalez, Tabajara Oliveira; Fumagalli, Marco Antônio; de Gomes, Cid André Fidelis Paula; Politti, Fabiano

    2015-03-19

    Nonspecific neck pain can cause considerable suffering, possible disability and reductions in quality of life and productivity. The aim of the proposed study is to evaluate the immediate effect of acupuncture on pain, cervical range of motion and electromyographic activity of the upper trapezius muscle in patients with nonspecific neck pain. A total of 12 patients with nonspecific neck pain and 12 healthy subjects will be enrolled in a randomized, single-blind crossover study. Each subject will receive two forms of treatment in random order: a single session of traditional acupuncture (acupoints: triple energizer 5, 'Wai-guan' and large intestine 11, 'Qu-chi') and sham acupuncture. To eliminate carry-over treatment effects, a one-week wash-out period will be respected between sessions. Surface electromyography will be used to determine motor control in the upper trapezius muscle before and after treatment. The outcome measures in the group with neck pain will be a numerical pain rating scale (range: 0 (no pain) to 10 (maximum pain)), documentation of the pain area on a body chart and cervical range of motion. Comparisons before and after acupuncture treatment will demonstrate whether acupoints affect the activity of the upper trapezius muscle, pain and cervical range of motion. The purpose of this randomized clinical trial is to evaluate the immediate effect of acupuncture on pain, cervical range of motion and electromyographic activity of the upper trapezius muscle in patients with nonspecific neck pain. Data will be published after the study is completed. The study will support the practice of evidence-based physical therapy for individuals with nonspecific neck pain. This trial was registered with Clinicaltrials.gov (identifier: NCT0984021 ) on 7 November 2013 ( https://clinicaltrials.gov/ct2/show/NCT01984021 ).

  9. The efficacy of chiropractic adjustments and PAIN®GONE therapy in the treatment of trapezius myofascial pain syndrome

    OpenAIRE

    2014-01-01

    M.Tech. (Chiropractic) Myofascial trigger points are very common and can become a painful part of most people’s life at one time or another. According to Travell and Simons (1999), active upper trapezius myofascial trigger points are common in patients presenting with neck pain. Myofascial pain syndrome is a regional muscle disorder that is one of the most common causes of persistent pain in the head, face and neck regions (Rachlin, 2002). The PAIN®GONE pen is a device that produces a high...

  10. Trapezius muscle EMG as predictor of mental stress

    NARCIS (Netherlands)

    Wijsman, J.L.P; Grundlehner, B.; Penders, J.; Hermens, Hermanus J.

    Stress is a growing problem in society and can cause musculoskeletal complaints. It would be useful to measure stress for prevention of stress-related health problems. An experiment is described in which EMG signals of the upper trapezius muscle were measured with a wireless system during three

  11. Evidence for repetitive load in the trapezius muscle during a tapping task.

    Science.gov (United States)

    Tomatis, L; Müller, C; Nakaseko, M; Läubli, T

    2012-08-01

    Many studies describe the trapezius muscle activation pattern during repetitive key-tapping focusing on continuous activation. The objectives of this study were to determine whether the upper trapezius is phasically active during supported key tapping, whether this activity is cross-correlated with forearm muscle activity, and whether trapezius activity depends on key characteristic. Thirteen subjects (29.7 ± 11.4 years) were tested. Surface EMG of the finger's extensor and flexor and of the trapezius muscles, as well as the key on-off signal was recorded while the subject performed a 2-min session of key tapping at 4 Hz. The linear envelopes obtained were cut into single tapping cycles extending from one onset to the next onset signal and subsequently time-normalized. Effect size between mean range and maximal standard deviation was calculated to determine as to whether a burst of trapezius muscle activation was present. Cross-correlation was used to determine the time-lag of the activity bursts between forearm and trapezius muscles. For each person the mean and standard deviation of the cross-correlations coefficient between forearm muscles and trapezius were determined. Results showed a burst of activation in the trapezius muscle during most of the tapping cycles. The calculated effect size was ≥0.5 in 67% of the cases. Cross-correlation factors between forearm and trapezius muscle activity were between 0.75 and 0.98 for both extensor and flexor muscles. The cross-correlated phasic trapezius activity did not depend on key characteristics. Trapezius muscle was dynamically active during key tapping; its activity was clearly correlated with forearm muscles' activity.

  12. Active pauses induce more variable electromyographic pattern of the trapezius muscle activity during computer work

    DEFF Research Database (Denmark)

    Samani, Afshin; Holtermann, Andreas; Søgaard, Karen

    2009-01-01

    , with passive (relax) and active (30% maximum voluntary contraction of shoulder elevation) pauses given every 2 min at two different work paces (low/high). Bipolar SEMG from four parts of the trapezius muscle was recorded. The relative rest time was higher for the lower parts compared with the upper......The aim of this laboratory study was to evaluate effects of active and passive pauses and investigate the distribution of the trapezius surface electromyographic (SEMG) activity during computer mouse work. Twelve healthy male subjects performed four sessions of computer work for 10 min in one day...... of the trapezius (pwork with active pause compared with passive one (p

  13. Effect of trapezius muscle strength on three-dimensional scapular kinematics

    OpenAIRE

    Turgut, Elif; Duzgun, Irem; Baltaci, Gul

    2016-01-01

    [Purpose] This study aimed to investigate the effect of trapezius muscle isometric strength on three-dimensional scapular kinematics in asymptomatic shoulders. [Subjects and Methods] Thirty asymptomatic subjects were included to the study. Isometric strengths of the upper, middle, and lower trapezius muscle were measured using a handheld dynamometer. Three-dimensional scapular kinematics was recorded by an electromagnetic tracking device during frontal and sagittal plane elevation. For each m...

  14. Comparing trapezius muscle activity in the different planes of shoulder elevation.

    Science.gov (United States)

    Ishigaki, Tomonobu; Ishida, Tomoya; Samukawa, Mina; Saito, Hiroshi; Hirokawa, Motoki; Ezawa, Yuya; Sugawara, Makoto; Tohyama, Harukazu; Yamanaka, Masanori

    2015-05-01

    [Purpose] The purpose of this study was to compare the upper, middle, and lower trapezius muscles' activity in the different planes of shoulder elevation. [Subjects] Twenty male subjects volunteered for this study. [Methods] Surface electromyographic (EMG) activity for each of the three regions of the trapezius muscles in the three different planes of elevation were collected while the participants maintained 30, 60, and 90 degrees of elevation in each plane. The EMG data were normalized with maximum voluntary isometric contraction (%MVIC), and compared among the planes at each angle of elevation. [Results] There were significantly different muscle activities among the elevation planes at each angle. [Conclusion] This study found that the three regions of the trapezius muscles changed their activity depending on the planes of shoulder elevation. These changes in the trapezius muscles could induce appropriate scapular motion to face the glenoid cavity in the correct directions in different planes of shoulder elevation.

  15. TRIGGER

    CERN Multimedia

    Wesley Smith

    Level-1 Trigger Hardware and Software The hardware of the trigger components has been mostly finished. The ECAL Endcap Trigger Concentrator Cards (TCC) are in production while Barrel TCC firmware has been upgraded, and the Trigger Primitives can now be stored by the Data Concentrator Card for readout by the DAQ. The Regional Calorimeter Trigger (RCT) system is complete, and the timing is being finalized. All 502 HCAL trigger links to RCT run without error. The HCAL muon trigger timing has been equalized with DT, RPC, CSC and ECAL. The hardware and firmware for the Global Calorimeter Trigger (GCT) jet triggers are being commissioned and data from these triggers is available for readout. The GCT energy sums from rings of trigger towers around the beam pipe beam have been changed to include two rings from both sides. The firmware for Drift Tube Track Finder, Barrel Sorter and Wedge Sorter has been upgraded, and the synchronization of the DT trigger is satisfactory. The CSC local trigger has operated flawlessly u...

  16. TRIGGER

    CERN Multimedia

    Roberta Arcidiacono

    2013-01-01

    Trigger Studies Group (TSG) The Trigger Studies Group has just concluded its third 2013 workshop, where all POGs presented the improvements to the physics object reconstruction, and all PAGs have shown their plans for Trigger development aimed at the 2015 High Level Trigger (HLT) menu. The Strategy for Trigger Evolution And Monitoring (STEAM) group is responsible for Trigger menu development, path timing, Trigger performance studies coordination, HLT offline DQM as well as HLT release, menu and conditions validation – this last task in collaboration with PdmV (Physics Data and Monte Carlo Validation group). In the last months the group has delivered several HLT rate estimates and comparisons, using the available data and Monte Carlo samples. The studies were presented at the Trigger workshops in September and December, and STEAM has contacted POGs and PAGs to understand the origin of the discrepancies observed between 8 TeV data and Monte Carlo simulations. The most recent results show what the...

  17. Trapezius aplasia: indications for a dual developmental origin of the trapezius muscle

    NARCIS (Netherlands)

    Nooij, Linda S.; Oostra, Roelof-Jan

    2006-01-01

    Aplasia of the trapezius muscle is a rarely encountered, mostly asymptomatic anomaly. We report a case of isolated unilateral complete trapezius aplasia that was noticed during a dissection course. Apart from isolated cases, trapezius aplasia may occur in different combinations with other muscle

  18. TRIGGER

    CERN Multimedia

    Wesley Smith

    Level-1 Trigger Hardware and Software The trigger synchronization procedures for running with cosmic muons and operating with the LHC were reviewed during the May electronics week. Firmware maintenance issues were also reviewed. Link tests between the new ECAL endcap trigger concentrator cards (TCC48) and the Regional Calorimeter Trigger have been performed. Firmware for the energy sum triggers and an upgraded tau trigger of the Global Calorimeter Triggers has been developed and is under test. The optical fiber receiver boards for the Track-Finder trigger theta links of the DT chambers are now all installed. The RPC trigger is being made more robust by additional chamber and cable shielding and also by firmware upgrades. For the CSC’s the front-end and trigger motherboard firmware have been updated. New RPC patterns and DT/CSC lookup tables taking into account phi asymmetries in the magnetic field configuration are under study. The motherboard for the new pipeline synchronizer of the Global Trigg...

  19. TRIGGER

    CERN Multimedia

    W. Smith

    2012-01-01

      Level-1 Trigger The Level-1 Trigger group is ready to deploy improvements to the L1 Trigger algorithms for 2012. These include new high-PT patterns for the RPC endcap, an improved CSC PT assignment, a new PT-matching algorithm for the Global Muon Trigger, and new calibrations for ECAL, HCAL, and the Regional Calorimeter Trigger. These should improve the efficiency, rate, and stability of the L1 Trigger. The L1 Trigger group also is migrating the online systems to SLC5. To make the data transfer from the Global Calorimeter Trigger to the Global Trigger more reliable and also to allow checking the data integrity online, a new optical link system has been developed by the GCT and GT groups and successfully tested at the CMS electronics integration facility in building 904. This new system is now undergoing further tests at Point 5 before being deployed for data-taking this year. New L1 trigger menus have recently been studied and proposed by Emmanuelle Perez and the L1 Detector Performance Group...

  20. TRIGGER

    CERN Multimedia

    W. Smith

    At the March meeting, the CMS trigger group reported on progress in production, tests in the Electronics Integration Center (EIC) in Prevessin 904, progress on trigger installation in the underground counting room at point 5, USC55, the program of trigger pattern tests and vertical slice tests and planning for the Global Runs starting this summer. The trigger group is engaged in the final stages of production testing, systems integration, and software and firmware development. Most systems are delivering final tested electronics to CERN. The installation in USC55 is underway and integration testing is in full swing. A program of orderly connection and checkout with subsystems and central systems has been developed. This program includes a series of vertical subsystem slice tests providing validation of a portion of each subsystem from front-end electronics through the trigger and DAQ to data captured and stored. After full checkout, trigger subsystems will be then operated in the CMS Global Runs. Continuous...

  1. TRIGGER

    CERN Multimedia

    Wesley Smith

    Level-1 Trigger Hardware and Software The production of the trigger hardware is now basically finished, and in time for the turn-on of the LHC. The last boards produced are the Trigger Concentrator Cards for the ECAL Endcaps (TCC-EE). After the recent installation of the four EE Dees, the TCC-EE prototypes were used for their commissioning. Production boards are arriving and are being tested continuously, with the last ones expected in November. The Regional Calorimeter Trigger hardware is fully integrated after installation of the last EE cables. Pattern tests from the HCAL up to the GCT have been performed successfully. The HCAL triggers are fully operational, including the connection of the HCAL-outer and forward-HCAL (HO/HF) technical triggers to the Global Trigger. The HCAL Trigger and Readout (HTR) board firmware has been updated to permit recording of the tower “feature bit” in the data. The Global Calorimeter Trigger hardware is installed, but some firmware developments are still n...

  2. TRIGGER

    CERN Multimedia

    by Wesley Smith

    2010-01-01

    Level-1 Trigger Hardware and Software The overall status of the L1 trigger has been excellent and the running efficiency has been high during physics fills. The timing is good to about 1%. The fine-tuning of the time synchronization of muon triggers is ongoing and will be completed after more than 10 nb-1 of data have been recorded. The CSC trigger primitive and RPC trigger timing have been refined. A new configuration for the CSC Track Finder featured modified beam halo cuts and improved ghost cancellation logic. More direct control was provided for the DT opto-receivers. New RPC Cosmic Trigger (RBC/TTU) trigger algorithms were enabled for collision runs. There is further work planned during the next technical stop to investigate a few of the links from the ECAL to the Regional Calorimeter Trigger (RCT). New firmware and a new configuration to handle trigger rate spikes in the ECAL barrel are also being tested. A board newly developed by the tracker group (ReTRI) has been installed and activated to block re...

  3. TRIGGER

    CERN Multimedia

    W. Smith

    2010-01-01

    Level-1 Trigger Hardware and Software The Level-1 Trigger hardware has performed well during both the recent proton-proton and heavy ion running. Efforts were made to improve the visibility and handling of alarms and warnings. The tracker ReTRI boards that prevent fixed frequencies of Level-1 Triggers are now configured through the Trigger Supervisor. The Global Calorimeter Trigger (GCT) team has introduced a buffer cleanup procedure at stops and a reset of the QPLL during configuring to ensure recalibration in case of a switch from the LHC clock to the local clock. A device to test the cables between the Regional Calorimeter Trigger and the GCT has been manufactured. A wrong charge bit was fixed in the CSC Trigger. The ECAL group is improving crystal masking and spike suppression in the trigger primitives. New firmware for the Drift Tube Track Finder (DTTF) sorters was developed to improve fake track tagging and sorting. Zero suppression was implemented in the DT Sector Collector readout. The track finder b...

  4. TRIGGER

    CERN Multimedia

    Wesley Smith

    Trigger Hardware The status of the trigger components was presented during the September CMS Week and Annual Review and at the monthly trigger meetings in October and November. Procedures for cold and warm starts (e.g. refreshing of trigger parameters stored in registers) of the trigger subsystems have been studied. Reviews of parts of the Global Calorimeter Trigger (GCT) and the Global Trigger (GT) have taken place in October and November. The CERN group summarized the status of the Trigger Timing and Control (TTC) system. All TTC crates and boards are installed in the underground counting room, USC55. The central clock system will be upgraded in December (after the Global Run at the end of November GREN) to the new RF2TTC LHC machine interface timing module. Migration of subsystem's TTC PCs to SLC4/ XDAQ 3.12 is being prepared. Work is on going to unify the access to Local Timing Control (LTC) and TTC CMS interface module (TTCci) via SOAP (Simple Object Access Protocol, a lightweight XML-based messaging ...

  5. TRIGGER

    CERN Multimedia

    W. Smith from contributions of C. Leonidopoulos

    2010-01-01

    Level-1 Trigger Hardware and Software Since nearly all of the Level-1 (L1) Trigger hardware at Point 5 has been commissioned, activities during the past months focused on the fine-tuning of synchronization, particularly for the ECAL and the CSC systems, on firmware upgrades and on improving trigger operation and monitoring. Periodic resynchronizations or hard resets and a shortened luminosity section interval of 23 seconds were implemented. For the DT sector collectors, an automatic power-off was installed in case of high temperatures, and the monitoring capabilities of the opto-receivers and the mini-crates were enhanced. The DTTF and the CSCTF now have improved memory lookup tables. The HCAL trigger primitive logic implemented a new algorithm providing better stability of the energy measurement in the presence of any phase misalignment. For the Global Calorimeter Trigger, additional Source Cards have been manufactured and tested. Testing of the new tau, missing ET and missing HT algorithms is underw...

  6. TRIGGER

    CERN Multimedia

    Wesley Smith

    Level-1 Trigger Hardware and Software The final parts of the Level-1 trigger hardware are now being put in place. For the ECAL endcaps, more than half of the Trigger Concentrator Cards for the ECAL Endcap (TCC-EE) are now available at CERN, such that one complete endcap can be covered. The Global Trigger now correctly handles ECAL calibration sequences, without being influenced by backpressure. The Regional Calorimeter Trigger (RCT) hardware is complete and working in USC55. Intra-crate tests of all 18 RCT crates and the Global Calorimeter Trigger (GCT) are regularly taking place. Pattern tests have successfully captured data from HCAL through RCT to the GCT Source Cards. HB/HE trigger data are being compared with emulator results to track down the very few remaining hardware problems. The treatment of hot and dead cells, including their recording in the database, has been defined. For the GCT, excellent agreement between the emulator and data has been achieved for jets and HF ET sums. There is still som...

  7. TRIGGER

    CERN Multimedia

    W. Smith

    Level-1 Trigger Hardware and Software The trigger system has been constantly in use in cosmic and commissioning data taking periods. During CRAFT running it delivered 300 million muon and calorimeter triggers to CMS. It has performed stably and reliably. During the abort gaps it has also provided laser and other calibration triggers. Timing issues, namely synchronization and latency issues, have been solved. About half of the Trigger Concentrator Cards for the ECAL Endcap (TCC-EE) are installed, and the firmware is being worked on. The production of the other half has started. The HCAL Trigger and Readout (HTR) card firmware has been updated, and new features such as fast parallel zero-suppression have been included. Repairs of drift tube (DT) trigger mini-crates, optical links and receivers of sector collectors are under way and have been completed on YB0. New firmware for the optical receivers of the theta links to the drift tube track finder is being installed. In parallel, tests with new eta track finde...

  8. TRIGGER

    CERN Multimedia

    R. Carlin with contributions from D. Acosta

    2012-01-01

    Level-1 Trigger Data-taking continues at cruising speed, with high availability of all components of the Level-1 trigger. We have operated the trigger up to a luminosity of 7.6E33, where we approached 100 kHz using the 7E33 prescale column.  Recently, the pause without triggers in case of an automatic "RESYNC" signal (the "settle" and "recover" time) was reduced in order to minimise the overall dead-time. This may become very important when the LHC comes back with higher energy and luminosity after LS1. We are also preparing for data-taking in the proton-lead run in early 2013. The CASTOR detector will make its comeback into CMS and triggering capabilities are being prepared for this. Steps to be taken include improved cooperation with the TOTEM trigger system and using the LHC clock during the injection and ramp phases of LHC. Studies are being finalised that will have a bearing on the Trigger Technical Design Report (TDR), which is to be rea...

  9. TRIGGER

    CERN Multimedia

    W. Smith

    At the December meeting, the CMS trigger group reported on progress in production, tests in the Electronics Integration Center (EIC) in Prevessin 904, progress on trigger installation in the underground counting room at point 5, USC55, and results from the Magnet Test and Cosmic Challenge (MTCC) phase II. The trigger group is engaged in the final stages of production testing, systems integration, and software and firmware development. Most systems are delivering final tested electronics to CERN. The installation in USC55 is underway and moving towards integration testing. A program of orderly connection and checkout with subsystems and central systems has been developed. This program includes a series of vertical subsystem slice tests providing validation of a portion of each subsystem from front-end electronics through the trigger and DAQ to data captured and stored. This is combined with operations and testing without beam that will continue until startup. The plans for start-up, pilot and early running tri...

  10. TRIGGER

    CERN Multimedia

    Wesley Smith

    2011-01-01

    Level-1 Trigger Hardware and Software New Forward Scintillating Counters (FSC) for rapidity gap measurements have been installed and integrated into the Trigger recently. For the Global Muon Trigger, tuning of quality criteria has led to improvements in muon trigger efficiencies. Several subsystems have started campaigns to increase spares by recovering boards or producing new ones. The barrel muon sector collector test system has been reactivated, new η track finder boards are in production, and φ track finder boards are under revision. In the CSC track finder, an η asymmetry problem has been corrected. New pT look-up tables have also improved efficiency. RPC patterns were changed from four out of six coincident layers to three out of six in the barrel, which led to a significant increase in efficiency. A new PAC firmware to trigger on heavy stable charged particles allows looking for chamber hit coincidences in two consecutive bunch-crossings. The redesign of the L1 Trigger Emulator...

  11. TRIGGER

    CERN Multimedia

    W. Smith, from contributions of D. Acosta

    2012-01-01

      The L1 Trigger group deployed several major improvements this year. Compared to 2011, the single-muon trigger rate has been reduced by a factor of 2 and the η coverage has been restored to 2.4, with high efficiency. During the current technical stop, a higher jet seed threshold will be applied in the Global Calorimeter Trigger in order to significantly reduce the strong pile-up dependence of the HT and multi-jet triggers. The currently deployed L1 menu, with the “6E33” prescales, has a total rate of less than 100 kHz and operates with detector readout dead time of less than 3% for luminosities up to 6.5 × 1033 cm–2s–1. Further prescale sets have been created for 7 and 8 × 1033 cm–2s–1 luminosities. The L1 DPG is evaluating the performance of the Trigger for upcoming conferences and publication. Progress on the Trigger upgrade was reviewed during the May Upgrade Week. We are investigating scenarios for stagin...

  12. TRIGGER

    CERN Multimedia

    W. Smith from contributions of C. Leonidopoulos, I. Mikulec, J. Varela and C. Wulz.

    Level-1 Trigger Hardware and Software Over the past few months, the Level-1 trigger has successfully recorded data with cosmic rays over long continuous stretches as well as LHC splash events, beam halo, and collision events. The L1 trigger hardware, firmware, synchronization, performance and readiness for beam operation were reviewed in October. All L1 trigger hardware is now installed at Point 5, and most of it is completely commissioned. While the barrel ECAL Trigger Concentrator Cards are fully operational, the recently delivered endcap ECAL TCC system is still being commissioned. For most systems there is a sufficient number of spares available, but for a few systems additional reserve modules are needed. It was decided to increase the overall L1 latency by three bunch crossings to increase the safety margin for trigger timing adjustments. In order for CMS to continue data taking during LHC frequency ramps, the clock distribution tree needs to be reset. The procedures for this have been tested. A repl...

  13. TRIGGER

    CERN Multimedia

    R. Arcidiacono

    2013-01-01

      In 2013 the Trigger Studies Group (TSG) has been restructured in three sub-groups: STEAM, for the development of new HLT menus and monitoring their performance; STORM, for the development of HLT tools, code and actual configurations; and FOG, responsible for the online operations of the High Level Trigger. The Strategy for Trigger Evolution And Monitoring (STEAM) group is responsible for Trigger Menu development, path timing, trigger performance studies coordination, HLT offline DQM as well as HLT release, menu and conditions validation – in collaboration and with the technical support of the PdmV group. Since the end of proton-proton data taking, the group has started preparing for 2015 data taking, with collisions at 13 TeV and 25 ns bunch spacing. The reliability of the extrapolation to higher energy is being evaluated comparing the trigger rates on 7 and 8 TeV Monte Carlo samples with the data taken in the past two years. The effect of 25 ns bunch spacing is being studied on the d...

  14. TRIGGER

    CERN Multimedia

    W. Smith

    Level-1 Trigger Hardware and Software The road map for the final commissioning of the level-1 trigger system has been set. The software for the trigger subsystems is being upgraded to run under CERN Scientific Linux 4 (SLC4). There is also a new release for the Trigger Supervisor (TS 1.4), which implies upgrade work by the subsystems. As reported by the CERN group, a campaign to tidy the Trigger Timing and Control (TTC) racks has begun. The machine interface was upgraded by installing the new RF2TTC module, which receives RF signals from LHC Point 4. Two Beam Synchronous Timing (BST) signals, one for each beam, can now be received in CMS. The machine group will define the exact format of the information content shortly. The margin on the locking range of the CMS QPLL is planned for study for different subsystems in the next Global Runs, using a function generator. The TTC software has been successfully tested on SLC4. Some TTC subsystems have already been upgraded to SLC4. The TTCci Trigger Supervisor ...

  15. TRIGGER

    CERN Multimedia

    by Wesley Smith

    2011-01-01

    Level-1 Trigger Hardware and Software After the winter shutdown minor hardware problems in several subsystems appeared and were corrected. A reassessment of the overall latency has been made. In the TTC system shorter cables between TTCci and TTCex have been installed, which saved one bunch crossing, but which may have required an adjustment of the RPC timing. In order to tackle Pixel out-of-syncs without influencing other subsystems, a special hardware/firmware re-sync protocol has been introduced in the Global Trigger. The link between the Global Calorimeter Trigger and the Global Trigger with the new optical Global Trigger Interface and optical receiver daughterboards has been successfully tested in the Electronics Integration Centre in building 904. New firmware in the GCT now allows a setting to remove the HF towers from energy sums. The HF sleeves have been replaced, which should lead to reduced rates of anomalous signals, which may allow their inclusion after this is validated. For ECAL, improvements i...

  16. TRIGGER

    CERN Multimedia

    W. Smith

    2011-01-01

    Level-1 Trigger Hardware and Software Overall the L1 trigger hardware has been running very smoothly during the last months of proton running. Modifications for the heavy-ion run have been made where necessary. The maximal design rate of 100 kHz can be sustained without problems. All L1 latencies have been rechecked. The recently installed Forward Scintillating Counters (FSC) are being used in the heavy ion run. The ZDC scintillators have been dismantled, but the calorimeter itself remains. We now send the L1 accept signal and other control signals to TOTEM. Trigger cables from TOTEM to CMS will be installed during the Christmas shutdown, so that the TOTEM data can be fully integrated within the CMS readout. New beam gas triggers have been developed, since the BSC-based trigger is no longer usable at high luminosities. In particular, a special BPTX signal is used after a quiet period with no collisions. There is an ongoing campaign to provide enough spare modules for the different subsystems. For example...

  17. TRIGGER

    CERN Multimedia

    J. Alimena

    2013-01-01

    Trigger Strategy Group The Strategy for Trigger Evolution And Monitoring (STEAM) group is responsible for the development of future High-Level Trigger menus, as well as of its DQM and validation, in collaboration and with the technical support of the PdmV group. Taking into account the beam energy and luminosity expected in 2015, a rough estimate of the trigger rates indicates a factor four increase with respect to 2012 conditions. Assuming that a factor two can be tolerated thanks to the increase in offline storage and processing capabilities, a toy menu has been developed using the new OpenHLT workflow to estimate the transverse energy/momentum thresholds that would halve the current trigger rates. The CPU time needed to run the HLT has been compared between data taken with 25 ns and 50 ns bunch spacing, for equivalent pile-up: no significant difference was observed on the global time per event distribution at the only available data point, corresponding to a pile-up of about 10 interactions. Using th...

  18. TRIGGER

    CERN Multimedia

    W. Smith

    Level-1 Trigger Hardware The CERN group is working on the TTC system. Seven out of nine sub-detector TTC VME crates with all fibers cabled are installed in USC55. 17 Local Trigger Controller (LTC) boards have been received from production and are in the process of being tested. The RF2TTC module replacing the TTCmi machine interface has been delivered and will replace the TTCci module used to mimic the LHC clock. 11 out of 12 crates housing the barrel ECAL off-detector electronics have been installed in USC55 after commissioning at the Electronics Integration Centre in building 904. The cabling to the Regional Calorimeter Trigger (RCT) is terminated. The Lisbon group has completed the Synchronization and Link mezzanine board (SLB) production. The Palaiseau group has fully tested and installed 33 out of 40 Trigger Concentrator Cards (TCC). The seven remaining boards are being remade. The barrel TCC boards have been tested at the H4 test beam, and good agreement with emulator predictions were found. The cons...

  19. The effect of physical and psychosocial loads on the trapezius muscle activity during computer keying tasks and rest periods

    DEFF Research Database (Denmark)

    Blangsted, Anne Katrine; Søgaard, Karen; Christensen, Hanne

    2004-01-01

    hand keying task-interspaced with short (30 s) and long (4 min) breaks-in sessions with and without a combination of cognitive and emotional stressors. Adding psychosocial loads to the same physical work did not increase the activity of the trapezius muscle on either the keying or the control side......The overall aim was to investigate the effect of psychosocial loads on trapezius muscle activity during computer keying work and during short and long breaks. In 12 female subjects, surface electromyography (EMG) was recorded bilaterally from the upper trapezius muscle during a standardized one...... resting level. During both short and long breaks, exposure to psychosocial loads also did not increase the activity of the trapezius muscle either on the side of the keying or the control hand. Of note is that during long breaks the muscle activity of the keying side as well as that of the control side...

  20. Single motor unit firing behaviour in the right trapezius muscle during rapid movement of right or left index finger.

    Directory of Open Access Journals (Sweden)

    Karen eSøgaard

    2014-11-01

    Full Text Available Computer work is associated with low level sustained activity in the trapezius muscle that may cause myalgia. The activity may be attention related or part of a general multijoint motor program providing stabilization of the shoulder girdle for precise finger manipulation. This study examines single motor unit (MU firing pattern in the right trapezius muscle during fast movements of ipsi or contralateral index finger. Modulated firing rate would support a general multi joint motor program, while a generally increased and continuous firing rate would support attention related activation. 12 healthy female subjects were seated at a computer work place with elbows and forearms supported. Ten double clicks (DC were performed with right and left index finger on a computer mouse instrumented with a trigger.Surface EMG was recorded from right and left trapezius muscle. Intramuscular EMG was recorded with a quadripolar wire electrode in the right trapezius.Surface EMG was analysed as %MVE. The intramuscular EMG was decomposed into individual MU action potential trains. Instantaneous firing rate (IFR was calculated from inter-spike interval with ISI shorter than 20 ms defined as doublets. IFR was averaged across 10 DC to show IFR modulation.Surface EMG in both right and left trapezius was 1.8-2.5%MVE. During right hand DC a total of 32 MUs were identified. Four subjects showed no activity. Four showed MU activity with weak or no variations related to the timing of DC. Four subjects showed large modulation in IFR with temporal relation to DC. During left hand DC 15 MUs were identified in 4 subjects, for two of the subjects with IFR modulations related to DC. Doublets was found as an integrated part of MU activation in the trapezius muscle and for one subject temporarily related to DC. In conclusion, DC with ipsi- and contralateral fast movements of the index finger was found to evoke biomechanically as well as attention related activity pattern in the

  1. An Otogenic Trapezius Abscess: A Case Report

    Directory of Open Access Journals (Sweden)

    Fazal I Wahid

    2012-03-01

    Full Text Available Introduction: An otogenic brain abscess is a common ENT problem but an otogenic trapezius abscess can also be experienced in otolaryngological practice, particularly in patients with chronic suppurative otitis media.   Case Report: We report a rare case of a trapezius abscess in an eight-year-old girl who presented at the ENT, Head and Neck Surgery Postgraduate Medical Institute, Lady Reading Hospital, Peshawar, Pakistan on 15th December, 2010, with a presenting complaint of discharge from her right ear that had been occurring for the last five years. An exploration of the patient’s right ear was performed, which showed that there was extensive cholesteatoma and tissue granulation tissues the antrum, attic and middle ear. The trapezius abscess had spread down to her back and was repeatedly drained. The patient was discharged on the 14th day following admission after making a complete recovery. After a regular follow-up period the child has remained disease free. The rare nature of this case prompted us to write this report.   Conclusion: Chronic suppurative otitis media is a common clinical problem in developing countries. It can result in a number of complications if not treated properly. Although an otogenic trapezius abscess is a rare complication of chronic suppurative otitis media, it must be kept in mind.    

  2. Electromyogram and perceived fatigue changes in the trapezius muscle during typewriting and recovery.

    Science.gov (United States)

    Kimura, Mitsutoshi; Sato, Hirotaka; Ochi, Mamoru; Hosoya, Satoshi; Sadoyama, Tsugutake

    2007-05-01

    The purpose of the present study was to investigate the development and recovery of muscle fatigue in the upper trapezius muscle by analyzing electromyographic signals. Six male subjects performed a simulated typewriting task for four 25-min sessions. During fatigue and the following rest periods, subjective fatigue and surface electromyography (EMG) from the trapezius muscle during isometric contraction at 30% maximum voluntary contraction (MVC) were periodically measured in the interval. We detected a significant decrease in muscle fiber conduction velocity (MFCV) (P = 0.008) and median frequency (MDF) (P = 0.026) as well as an increase in root mean square (RMS) (P = 0.039) and subjective fatigue (P = 0.0004) during the fatigue period. During the recovery period, subjective fatigue decreased drastically and significantly (P = 0.0004), however, the EMG parameters did not recover completely. Thus, physiological muscle fatigue in the trapezius developed in accordance with subjective muscle fatigue during typewriting. On the other hand, differences between the physiological and subjective parameters were found during recovery. Further studies should be necessary to reveal the discrepancy could be a major factor of a transition from temporal phenomena to serious chronic muscle fatigue and to identify the necessity of some guidelines to prevent VDT work-related chronic muscle fatigue in the trapezius.

  3. Upper-Limb Recovery After Stroke: A Randomized Controlled Trial Comparing EMG-Triggered, Cyclic, and Sensory Electrical Stimulation.

    Science.gov (United States)

    Wilson, Richard D; Page, Stephen J; Delahanty, Michael; Knutson, Jayme S; Gunzler, Douglas D; Sheffler, Lynne R; Chae, John

    2016-11-01

    This study compared the effect of cyclic neuromuscular electrical stimulation (NMES), electromyographically (EMG)-triggered NMES, and sensory stimulation on motor impairment and activity limitations in patients with upper-limb hemiplegia. This was a multicenter, single-blind, multiarm parallel-group study of nonhospitalized hemiplegic stroke survivors within 6 months of stroke. A total of 122 individuals were randomized to receive either cyclic NMES, EMG-triggered NMES, or sensory stimulation twice every weekday in 40-minute sessions, over an 8 week-period. Patients were followed for 6 months after treatment concluded. There were significant increases in the Fugl-Meyer Assessment [F(1, 111) = 92.6, P stimulation therapy applied within 6 months of stroke. Improvements were likely a result of spontaneous recovery. There was no difference based on the type of electrical stimulation that was administered. © The Author(s) 2016.

  4. Intra and inter-rater reliability of infrared image analysis of masticatory and upper trapezius muscles in women with and without temporomandibular disorder Confiabilidade intra e interexaminador da análise de imagens infravermelhas dos músculos mastigatórios e trapézio superior em mulheres com e sem disfunção temporomandibular

    Directory of Open Access Journals (Sweden)

    Ana C. S Costa

    2013-02-01

    Full Text Available BACKGROUND: Infrared thermography is an aid tool that can be used to evaluate several pathologies given its efficiency in analyzing the distribution of skin surface temperature. OBJECTIVES: To propose two forms of infrared image analysis of the masticatory and upper trapezius muscles, and to determine the intra and inter-rater reliability of both forms of analysis. METHOD: Infrared images of masticatory and upper trapezius muscles of 64 female volunteers with and without temporomandibular disorder (TMD were collected. Two raters performed the infrared image analysis, which occurred in two ways: temperature measurement of the muscle length and in central portion of the muscle. The Intraclass Correlation Coefficient (ICC was used to determine the intra and inter-rater reliability. RESULTS: The ICC showed excellent intra and inter-rater values for both measurements: temperature measurement of the muscle length (TMD group, intra-rater, ICC ranged from 0.996 to 0.999, inter-rater, ICC ranged from 0.992 to 0.999; control group, intra-rater, ICC ranged from 0.993 to 0.998, inter-rater, ICC ranged from 0.990 to 0.998, and temperature measurement of the central portion of the muscle (TMD group, intra-rater, ICC ranged from 0.981 to 0.998, inter-rater, ICC ranged from 0.971 to 0.998; control group, intra-rater, ICC ranged from 0.887 to 0.996, inter-rater, ICC ranged from 0.852 to 0.996. CONCLUSION: The results indicated that temperature measurements of the masticatory and upper trapezius muscles carried out by the analysis of the muscle length and central portion yielded excellent intra and inter-rater reliability.CONTEXTUALIZAÇÃO: A termografia infravermelha vem sendo utilizada como instrumento auxiliar na avaliação de patologias diversas, dada a sua eficiência na investigação da distribuição da temperatura superficial cutânea. OBJETIVOS: Propor duas formas de análise das imagens infravermelhas dos músculos mastigatórios e trapézio superior

  5. EEG-Triggered Functional Electrical Stimulation Therapy for Restoring Upper Limb Function in Chronic Stroke with Severe Hemiplegia

    Directory of Open Access Journals (Sweden)

    Cesar Marquez-Chin

    2016-01-01

    Full Text Available We report the therapeutic effects of integrating brain-computer interfacing technology and functional electrical stimulation therapy to restore upper limb reaching movements in a 64-year-old man with severe left hemiplegia following a hemorrhagic stroke he sustained six years prior to this study. He completed 40 90-minute sessions of functional electrical stimulation therapy using a custom-made neuroprosthesis that facilitated 5 different reaching movements. During each session, the participant attempted to reach with his paralyzed arm repeatedly. Stimulation for each of the movement phases (e.g., extending and retrieving the arm was triggered when the power in the 18 Hz–28 Hz range (beta frequency range of the participant’s EEG activity, recorded with a single electrode, decreased below a predefined threshold. The function of the participant’s arm showed a clinically significant improvement in the Fugl-Meyer Assessment Upper Extremity (FMA-UE subscore (6 points as well as moderate improvement in Functional Independence Measure Self-Care subscore (7 points. The changes in arm’s function suggest that the combination of BCI technology and functional electrical stimulation therapy may restore voluntary motor function in individuals with chronic hemiplegia which results in severe upper limb deficit (FMA-UE ≤ 15, a population that does not benefit from current best-practice rehabilitation interventions.

  6. Relationship between sleep stages and nocturnal trapezius muscle activity.

    Science.gov (United States)

    Müller, Christian; Nicoletti, Corinne; Omlin, Sarah; Brink, Mark; Läubli, Thomas

    2015-06-01

    Former studies reported a relationship between increased nocturnal low level trapezius muscle activity and neck or shoulder pain but it has not been explored whether trapezius muscle relaxation is related to sleep stages. The goal of the present study was to investigate whether trapezius muscle activity is related to different sleep stages, as measured by polysomnography. Twenty one healthy subjects were measured on four consecutive nights in their homes, whereas the first night served as adaptation night. The measurements included full polysomnography (electroencephalography (EEG), electrooculography (EOG), electromyography (EMG) and electrocardiography (ECG)), as well as surface EMG of the m. trapezius descendens of the dominant arm. Periods with detectable EMG activity of the trapezius muscle lasted on average 1.5% of the length of the nights and only in four nights it lasted longer than 5% of sleeping time. Neither rest time nor the length of periods with higher activity levels of the trapezius muscle did significantly differ between sleep stages. We found no evidence that nocturnal trapezius muscle activity is markedly moderated by the different sleep stages. Thus the results support that EMG measurements of trapezius muscle activity in healthy subjects can be carried out without concurrent polysomnographic recordings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. A pilot study using Tissue Velocity Ultrasound Imaging (TVI to assess muscle activity pattern in patients with chronic trapezius myalgia

    Directory of Open Access Journals (Sweden)

    Brodin Lars-Åke

    2008-09-01

    Full Text Available Abstract Background Different research techniques indicate alterations in muscle tissue and in neuromuscular control of aching muscles in patients with chronic localized pain. Ultrasound can be used for analysis of muscle tissue dynamics in clinical practice. Aim This study introduces a new muscle tissue sensitive ultrasound technique in order to provide a new methodology for providing a description of local muscle changes. This method is applied to investigate trapezius muscle tissue response – especially with respect to specific regional deformation and deformation rates – during concentric shoulder elevation in patients with chronic trapezius myalgia and healthy controls before and after pain provocation. Methods Patients with trapezius myalgia and healthy controls were analyzed using an ultrasound system equipped with tissue velocity imaging (TVI. The patients performed a standardized 3-cm concentric shoulder elevation before and after pain provocation/exercise at a standardized elevation tempo (30 bpm. A standardized region of interest (ROI, an ellipsis with a size that captures the upper and lower fascia of the trapezius muscle (4 cm width at rest, was placed in the first frame of the loop registration of the elevation. The ROI was re-anchored frame by frame following the same anatomical landmark in the basal fascia during all frames of the concentric phase. In cardiac measurement, tissue velocities are measured in the axial projection towards and against the probe where red colour represents shortening and red lengthening. In the case of measuring the trapezius muscle, tissue deformation measurements are made orthogonally, thus, indirectly. Based on the assumption of muscle volume incompressibility, blue represents tissue contraction and red relaxation. Within the ROI, two variables were calculated as a function of time: deformation and deformation rate. Hereafter, max, mean, and quadratic mean values (RMS of each variable were

  8. Additional Effect of Static Ultrasound and Diadynamic Currents on Myofascial Trigger Points in a Manual Therapy Program for Patients With Chronic Neck Pain: A Randomized Clinical Trial.

    Science.gov (United States)

    Dibai-Filho, Almir Vieira; de Oliveira, Alessandra Kelly; Girasol, Carlos Eduardo; Dias, Fabiana Rodrigues Cancio; Guirro, Rinaldo Roberto de Jesus

    2017-04-01

    To assess the additional effect of static ultrasound and diadynamic currents on myofascial trigger points in a manual therapy program to treat individuals with chronic neck pain. A single-blind randomized trial was conducted. Both men and women, between ages 18 and 45, with chronic neck pain and active myofascial trigger points in the upper trapezius were included in the study. Subjects were assigned to 3 different groups: group 1 (n = 20) was treated with manual therapy; group 2 (n = 20) was treated with manual therapy and static ultrasound; group 3 (n = 20) was treated with manual therapy and diadynamic currents. Individuals were assessed before the first treatment session, 48 hours after the first treatment session, 48 hours after the tenth treatment session, and 4 weeks after the last session. There was no group-versus-time interaction for Numeric Rating Scale, Neck Disability Index, Pain-Related Self-Statement Scale, pressure pain threshold, cervical range of motion, and skin temperature (F-value range, 0.089-1.961; P-value range, 0.106-0.977). Moreover, we found no differences between groups regarding electromyographic activity (P > 0.05). The use of static ultrasound or diadynamic currents on myofascial trigger points in upper trapezius associated with a manual therapy program did not generate greater benefits than manual therapy alone.

  9. Effects of visually demanding near work on trapezius muscle activity.

    Science.gov (United States)

    Zetterberg, C; Forsman, M; Richter, H O

    2013-10-01

    Poor visual ergonomics is associated with visual and neck/shoulder discomfort, but the relation between visual demands and neck/shoulder muscle activity is unclear. The aims of this study were to investigate whether trapezius muscle activity was affected by: (i) eye-lens accommodation; (ii) incongruence between accommodation and convergence; and (iii) presence of neck/shoulder discomfort. Sixty-six participants (33 controls and 33 with neck pain) performed visually demanding near work under four different trial-lens conditions. Results showed that eye-lens accommodation per se did not affect trapezius muscle activity significantly. However, when incongruence between accommodation and convergence was present, a significant positive relationship between eye-lens accommodation and trapezius muscle activity was found. There were no significant group-differences. It was concluded that incongruence between accommodation and convergence is an important factor in the relation between visually demanding near work and trapezius muscle activity. The relatively low demands on accommodation and convergence in the present study imply that visually demanding near work may contribute to increased muscle activity, and over time to the development of near work related neck/shoulder discomfort. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Voluntary Ambulation by Upper Limb-Triggered HAL® in Patients with Complete Quadri/Paraplegia Due to Chronic Spinal Cord Injury.

    Science.gov (United States)

    Shimizu, Yukiyo; Kadone, Hideki; Kubota, Shigeki; Suzuki, Kenji; Abe, Tetsuya; Ueno, Tomoyuki; Soma, Yuichiro; Sankai, Yoshiyuki; Hada, Yasushi; Yamazaki, Masashi

    2017-01-01

    Patients with complete paraplegia after spinal cord injury (SCI) are unable to stand or walk on their own. Standing exercise decreases the risk of decubitus ulcers, osteoporosis, and joint deformities in patients with SCI. Conventional gait training for complete paraplegia requires excessive upper limb usage for weight bearing and is difficult in cases of complete quadriplegia. The purpose of this study was to describe voluntary ambulation triggered by upper limb activity using the Hybrid Assistive Limb® (HAL) in patients with complete quadri/paraplegia after chronic SCI. Four patients (3 men, 1 woman) were enrolled in this study. The mean patient age ± standard deviation was 37.2 ± 17.8 (range, 20-67) years. Clinical evaluation before intervention revealed the following findings: case 1, neurological level C6, American Spinal Cord Injury Association impairment scale (AIS) grade B; case 2, T6, AIS A; case 3, T10 AIS A; and case 4, T11, AIS A. The HAL intervention consisted of 10 sessions. Each HAL session lasted 60-90 min. The HAL electrodes for hip and knee flexion-extension were placed on the anterior and posterior sides of the upper limbs contralaterally corresponding to each of the lower limbs. Surface electromyography (EMG) was used to evaluate muscle activity of the tensor fascia lata and quadriceps femoris (Quad) in synchronization with a Vicon motion capture system. The modified Ashworth scale (mAs) score was also evaluated before and after each session. All participants completed all 10 sessions. Cases 1, 2, and 3 demonstrated significant decreases in mAs score after the sessions compared to pre-session measurements. In all cases, EMG before the intervention showed no apparent activation in either Quad. However, gait phase dependent activity of the lower limb muscles was seen during voluntarily triggered ambulation driven by upper limb muscle activities. In cases 3 and 4, active contraction in both Quads was observed after intervention. These findings

  11. Voluntary Ambulation by Upper Limb-Triggered HAL® in Patients with Complete Quadri/Paraplegia Due to Chronic Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Yukiyo Shimizu

    2017-11-01

    Full Text Available Patients with complete paraplegia after spinal cord injury (SCI are unable to stand or walk on their own. Standing exercise decreases the risk of decubitus ulcers, osteoporosis, and joint deformities in patients with SCI. Conventional gait training for complete paraplegia requires excessive upper limb usage for weight bearing and is difficult in cases of complete quadriplegia. The purpose of this study was to describe voluntary ambulation triggered by upper limb activity using the Hybrid Assistive Limb® (HAL in patients with complete quadri/paraplegia after chronic SCI. Four patients (3 men, 1 woman were enrolled in this study. The mean patient age ± standard deviation was 37.2 ± 17.8 (range, 20–67 years. Clinical evaluation before intervention revealed the following findings: case 1, neurological level C6, American Spinal Cord Injury Association impairment scale (AIS grade B; case 2, T6, AIS A; case 3, T10 AIS A; and case 4, T11, AIS A. The HAL intervention consisted of 10 sessions. Each HAL session lasted 60–90 min. The HAL electrodes for hip and knee flexion-extension were placed on the anterior and posterior sides of the upper limbs contralaterally corresponding to each of the lower limbs. Surface electromyography (EMG was used to evaluate muscle activity of the tensor fascia lata and quadriceps femoris (Quad in synchronization with a Vicon motion capture system. The modified Ashworth scale (mAs score was also evaluated before and after each session. All participants completed all 10 sessions. Cases 1, 2, and 3 demonstrated significant decreases in mAs score after the sessions compared to pre-session measurements. In all cases, EMG before the intervention showed no apparent activation in either Quad. However, gait phase dependent activity of the lower limb muscles was seen during voluntarily triggered ambulation driven by upper limb muscle activities. In cases 3 and 4, active contraction in both Quads was observed after intervention

  12. Validity and Reliability of Clinical Examination in the Diagnosis of Myofascial Pain Syndrome and Myofascial Trigger Points in Upper Quarter Muscles.

    Science.gov (United States)

    Mayoral Del Moral, Orlando; Torres Lacomba, María; Russell, I Jon; Sánchez Méndez, Óscar; Sánchez Sánchez, Beatriz

    2017-12-15

    To determine whether two independent examiners can agree on a diagnosis of myofascial pain syndrome (MPS). To evaluate interexaminer reliability in identifying myofascial trigger points in upper quarter muscles. To evaluate the reliability of clinical diagnostic criteria for the diagnosis of MPS. To evaluate the validity of clinical diagnostic criteria for the diagnosis of MPS. Validity and reliability study. Provincial Hospital. Toledo, Spain. Twenty myofascial pain syndrome patients and 20 healthy, normal control subjects, enrolled by a trained and experienced examiner. Ten bilateral muscles from the upper quarter were evaluated by two experienced examiners. The second examiner was blinded to the diagnosis group. The MPS diagnosis required at least one muscle to have an active myofascial trigger point. Three to four days separated the two examinations. The primary outcome measure was the frequency with which the two examiners agreed on the classification of the subjects as patients or as healthy controls. The kappa statistic (K) was used to determine the level of agreement between both examinations, interpreted as very good (0.81-1.00), good (0.61-0.80), moderate (0.41-0.60), fair (0.21-0.40), or poor (≤0.20). Interexaminer reliability for identifying subjects with MPS was very good (K = 1.0). Interexaminer reliability for identifying muscles leading to a diagnosis of MPS was also very good (K = 0.81). Sensitivity and specificity showed high values for most examination tests in all muscles, which confirms the validity of clinical diagnostic criteria in the diagnosis of MPS. Interrater reliability between two expert examiners identifying subjects with MPS involving upper quarter muscles exhibited substantial agreement. These results suggest that clinical criteria can be valid and reliable in the diagnosis of this condition. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  13. Restrictive versus liberal blood transfusion for acute upper gastrointestinal bleeding (TRIGGER): a pragmatic, open-label, cluster randomised feasibility trial.

    Science.gov (United States)

    Jairath, Vipul; Kahan, Brennan C; Gray, Alasdair; Doré, Caroline J; Mora, Ana; James, Martin W; Stanley, Adrian J; Everett, Simon M; Bailey, Adam A; Dallal, Helen; Greenaway, John; Le Jeune, Ivan; Darwent, Melanie; Church, Nicholas; Reckless, Ian; Hodge, Renate; Dyer, Claire; Meredith, Sarah; Llewelyn, Charlotte; Palmer, Kelvin R; Logan, Richard F; Travis, Simon P; Walsh, Timothy S; Murphy, Michael F

    2015-07-11

    Transfusion thresholds for acute upper gastrointestinal bleeding are controversial. So far, only three small, underpowered studies and one single-centre trial have been done. Findings from the single-centre trial showed reduced mortality with restrictive red blood cell (RBC) transfusion. We aimed to assess whether a multicentre, cluster randomised trial is a feasible method to substantiate or refute this finding. In this pragmatic, open-label, cluster randomised feasibility trial, done in six university hospitals in the UK, we enrolled all patients aged 18 years or older with new presentations of acute upper gastrointestinal bleeding, irrespective of comorbidity, except for exsanguinating haemorrhage. We randomly assigned hospitals (1:1) with a computer-generated randomisation sequence (random permuted block size of 6, without stratification or matching) to either a restrictive (transfusion when haemoglobin concentration fell below 80 g/L) or liberal (transfusion when haemoglobin concentration fell below 100 g/L) RBC transfusion policy. Neither patients nor investigators were masked to treatment allocation. Feasibility outcomes were recruitment rate, protocol adherence, haemoglobin concentration, RBC exposure, selection bias, and information to guide design and economic evaluation of the phase 3 trial. Main exploratory clinical outcomes were further bleeding and mortality at day 28. We did analyses on all enrolled patients for whom an outcome was available. This trial is registered, ISRCTN85757829 and NCT02105532. Between Sept 3, 2012, and March 1, 2013, we enrolled 936 patients across six hospitals (403 patients in three hospitals with a restrictive policy and 533 patients in three hospitals with a liberal policy). Recruitment rate was significantly higher for the liberal than for the restrictive policy (62% vs 55%; p=0·04). Despite some baseline imbalances, Rockall and Blatchford risk scores were identical between policies. Protocol adherence was 96% (SD 10) in

  14. Shoulder kinematics and spatial pattern of trapezius electromyographic activity in real and virtual environments.

    Directory of Open Access Journals (Sweden)

    Afshin Samani

    Full Text Available The design of an industrial workstation tends to include ergonomic assessment steps based on a digital mock-up and a virtual reality setup. Lack of interaction and system fidelity is often reported as a main issue in such virtual reality applications. This limitation is a crucial issue as thorough ergonomic analysis is required for an investigation of the biomechanics. In the current study, we investigated the biomechanical responses of the shoulder joint in a simulated assembly task for comparison with the biomechanical responses in virtual environments. Sixteen male healthy novice subjects performed the task on three different platforms: real (RE, virtual (VE, and virtual environment with force feedback (VEF with low and high precision demands. The subjects repeated the task 12 times (i.e., 12 cycles. High density electromyography from the upper trapezius and rotation angles of the shoulder joint were recorded and split into the cycles. The angular trajectories and velocity profiles of the shoulder joint angles over a cycle were computed in 3D. The inter-subject similarity in terms of normalized mutual information on kinematics and electromyography was investigated. Compared with RE the task in VE and VEF was characterized by lower kinematic maxima. The inter-subject similarity in RE compared with intra-subject similarity across the platforms was lower in terms of movement trajectories and greater in terms of trapezius muscle activation. The precision demand resulted in lower inter- and intra-subject similarity across platforms. The proposed approach identifies biomechanical differences in the shoulder joint in both VE and VEF compared with the RE platform, but these differences are less marked in VE mostly due to technical limitations of co-localizing the force feedback system in the VEF platform.

  15. Comparison of Muscle Fatigue Effects on Electromyographic Onset Latency of Trapezius Muscle in Posterior-Anterior Perturbation between Patients with Chronic Neck Pain and Healthy Persons

    Directory of Open Access Journals (Sweden)

    Zahra Rojhani-Shirazi

    2008-07-01

    Full Text Available Objective: Fatigue process in patients with neck pain was happened more quickly than healthy persons and neck muscle fatigue increased body sway during standing, but there is less evidence about the behavior of these muscles in dynamic conditions such as external perturbation, so this study was done to investigate the effect of muscle fatigue on onset latency of upper trapezius muscle in posterior-anterior perturbation among patients with chronic neck pain and healthy individuals. Materials & Methods: In this quasi experimental and interventional study 16 patients with chronic neck pain (intervention group and 16 healthy individuals (control group were selected by simple and convenient sampling and based on inclusive and exclusive criteria. Data collection was done by using questionnaire and doing some tests and the main equipments were dynamometer, accelerometer and surface electromyography. The weight equal to 30% of maximum voluntary contraction used to produce fatigue process and 10% of body weight used to produce perturbation. Independent T test, Paired T test and Repeated ANOVA were used for data analysis. Results: There was significant difference in onset latency of upper Trapezius muscle in posterior – anterior perturbation between two groups, before (P=0.006 and after (P=0.026 fatigue. This means that the onset latency was increased in healthy individuals and decreased in patients after fatigue. Also, there was significant difference in onset latency of Trapezius muscle in posterior – anterior perturbation between before and after fatigue in patients group (P<0.001 and healthy persons group (P=0.04. Conclusion: Pain can change the onset latency of trapezius muscle and possibly it can decrease muscle activity in deep muscle and change the pattern of muscle activation. Fatigue as an exaggerated risk factor can decrease onset latency of superficial muscle in patients with chronic neck pain to stabilize the system, that it can increase

  16. Decreased thickness of the lower trapezius muscle in patients with unilateral neck pain.

    Science.gov (United States)

    Uthaikhup, Sureeporn; Pensri, Chalomjai; Kawsoiy, Kanokon

    2016-09-01

    Thickness of the lower trapezius muscle in patients with neck pain has not been established. We examined the thickness of the lower trapezius muscle in patients with and without unilateral neck pain. Twenty women with unilateral (right) neck pain and 20 matched controls participated in the study. Thickness of the lower trapezius muscles was measured bilaterally at rest (0 ° and 120 ° of shoulder abduction) and during contraction (120 ° of shoulder abduction) using ultrasound imaging. The neck pain group had smaller thickness of the lower trapezius muscle on the painful side compared with controls both at rest and during contraction (P  0.05). Patients with neck pain had smaller thickness of the lower trapezius muscle on the painful side compared with healthy controls. Muscle Nerve 54: 439-443, 2016. © 2015 Wiley Periodicals, Inc.

  17. Muscle trigger point therapy in tension-type headache.

    Science.gov (United States)

    Alonso-Blanco, Cristina; de-la-Llave-Rincón, Ana Isabel; Fernández-de-las-Peñas, César

    2012-03-01

    Recent evidence suggests that active trigger points (TrPs) in neck and shoulder muscles contribute to tension-type headache. Active TrPs within the suboccipital, upper trapezius, sternocleidomastoid, temporalis, superior oblique and lateral rectus muscles have been associated with chronic and episodic tension-type headache forms. It seems that the pain profile of this headache may be provoked by referred pain from active TrPs in the posterior cervical, head and shoulder muscles. In fact, the presence of active TrPs has been related to a higher degree of sensitization in tension-type headache. Different therapeutic approaches are proposed for proper TrP management. Preliminary evidence indicates that inactivation of TrPs may be effective for the management of tension-type headache, particularly in a subgroup of patients who may respond positively to this approach. Different treatment approaches targeted to TrP inactivation are discussed in the current paper, focusing on tension-type headache. New studies are needed to further delineate the relationship between muscle TrP inactivation and tension-type headache.

  18. Single motor unit firing behavior in the right trapezius muscle during rapid movement of right or left index finger

    DEFF Research Database (Denmark)

    Søgaard, Karen; Olsen, Henrik B; Blangsted, Anne K

    2014-01-01

    were defined as doublets. For all MU IFR was spike triggered averaged across the 10 DC to show the modulation during DC as well as for calculation of the cross correlation coefficient (CCC). RESULTS: All subjects showed surface EMG activity in both right and left trapezius ranging from 1.8 %MVE to 2...... as %MVE. The intramuscular EMG signals were decomposed into individual MU action potential trains using a computer algorithm based on signal shape recognition and manual editing. Instantaneous firing rate (IFR) was calculated as the inverse of each inter-spike interval (ISI). All ISI shorter than 20 ms...... in IFR with a clear temporal relation to the DC. During left hand DC 15 MUs were identified in four subjects, for two of the subjects with IFR modulations clearly related to DC. During both ipsi- and contralateral DC, doublets occurred sporadically as well as related to DC Conclusion: In conclusion, DC...

  19. Calo trigger acquisition system

    CERN Multimedia

    Franchini, Matteo

    2016-01-01

    Calo trigger acquisition system - Evolution of the acquisition system from a multiple boards system (upper, orange cables) to a single board one (below, light blue cables) where all the channels are collected in a single board.

  20. The influence of biofeedback training on trapezius activity and rest during occupational computer work

    DEFF Research Database (Denmark)

    Holtermann, A; Søgaard, K; Christensen, H

    2008-01-01

    The aim of this study was to investigate effects of biofeedback training on trapezius activity and rest (gaps) during occupational computer work. A randomized controlled trial with 164 computer workers was performed. Two groups working with computer mouse more than 50% (n = 64) and less than 25% (n....... By improving trapezius inactivity during computer work, biofeedback training may have the potential to prevent trapezius myalgia in computer workers....... muscles during normal computer work was recorded. Changes in discomfort/pain were not recorded. The biofeedback training reduced activity (P

  1. Algogenic substances and metabolic status in work-related Trapezius Myalgia

    DEFF Research Database (Denmark)

    Gerdle, Björn; Kristiansen, Jesper; Larsson, Britt

    2014-01-01

    (LDH), substance P, and N-terminal propeptide of procollagen type I (PINP) in the trapezius muscle at rest and during repetitive/stressful work. These data were also used in multivariate analyses together with previously presented data (Eur J Appl Physiol 108:657-669, 2010): trapezius muscle blood flow......BACKGROUND: This study compares the levels of algesic substances between subjects with trapezius myalgia (TM) and healthy controls (CON) and explores the multivariate correlation pattern between these substances, pain, and metabolic status together with relative blood flow changes reported in our...

  2. Quantitative Ultrasound Using Texture Analysis of Myofascial Pain Syndrome in the Trapezius.

    Science.gov (United States)

    Kumbhare, Dinesh A; Ahmed, Sara; Behr, Michael G; Noseworthy, Michael D

    2018-01-01

    Objective-The objective of this study is to assess the discriminative ability of textural analyses to assist in the differentiation of the myofascial trigger point (MTrP) region from normal regions of skeletal muscle. Also, to measure the ability to reliably differentiate between three clinically relevant groups: healthy asymptomatic, latent MTrPs, and active MTrP. Methods-18 and 19 patients were identified with having active and latent MTrPs in the trapezius muscle, respectively. We included 24 healthy volunteers. Images were obtained by research personnel, who were blinded with respect to the clinical status of the study participant. Histograms provided first-order parameters associated with image grayscale. Haralick, Galloway, and histogram-related features were used in texture analysis. Blob analysis was conducted on the regions of interest (ROIs). Principal component analysis (PCA) was performed followed by multivariate analysis of variance (MANOVA) to determine the statistical significance of the features. Results-92 texture features were analyzed for factorability using Bartlett's test of sphericity, which was significant. The Kaiser-Meyer-Olkin measure of sampling adequacy was 0.94. PCA demonstrated rotated eigenvalues of the first eight components (each comprised of multiple texture features) explained 94.92% of the cumulative variance in the ultrasound image characteristics. The 24 features identified by PCA were included in the MANOVA as dependent variables, and the presence of a latent or active MTrP or healthy muscle were independent variables. Conclusion-Texture analysis techniques can discriminate between the three clinically relevant groups.

  3. Trapezius muscle activity increases during near work activity regardless of accommodation/vergence demand level.

    Science.gov (United States)

    Richter, H O; Zetterberg, C; Forsman, M

    2015-07-01

    To investigate if trapezius muscle activity increases over time during visually demanding near work. The vision task consisted of sustained focusing on a contrast-varying black and white Gabor grating. Sixty-six participants with a median age of 38 (range 19-47) fixated the grating from a distance of 65 cm (1.5 D) during four counterbalanced 7-min periods: binocularly through -3.5 D lenses, and monocularly through -3.5 D, 0 D and +3.5 D. Accommodation, heart rate variability and trapezius muscle activity were recorded in parallel. General estimating equation analyses showed that trapezius muscle activity increased significantly over time in all four lens conditions. A concurrent effect of accommodation response on trapezius muscle activity was observed with the minus lenses irrespective of whether incongruence between accommodation and convergence was present or not. Trapezius muscle activity increased significantly over time during the near work task. The increase in muscle activity over time may be caused by an increased need of mental effort and visual attention to maintain performance during the visual tasks to counteract mental fatigue.

  4. Strength training increases the size of the satellite cell pool in type I and II fibres of chronically painful trapezius muscle in females

    DEFF Research Database (Denmark)

    Mackey, Abigail; Andersen, Lars L; Frandsen, Ulrik

    2011-01-01

    ) and general fitness training (GFT, n = 16) to augment the satellite cell (SC) and macrophage pools in the trapezius muscles of women diagnosed with trapezius myalgia. A group receiving general health information (REF, n = 8) served as a control. Muscle biopsies were collected from the trapezius muscles...

  5. Muscle oxygenation and glycolysis in females with trapezius myalgia during stress and repetitive work using microdialysis and NIRS

    DEFF Research Database (Denmark)

    Sjøgaard, Gisela; Rosendal, Lars; Kristiansen, Jesper

    2010-01-01

    The aim of this investigation was to study female workers active in the labour market for differences between those with trapezius myalgia (MYA) and without (CON) during repetitive pegboard (PEG) and stress (STR) tasks regarding (1) relative muscle load, (2) trapezius muscle blood flow, (3...

  6. Muscle oxygenation and glycolysis in females with trapezius myalgia during stress and repetitive work using microdialysis and NIRS

    DEFF Research Database (Denmark)

    Sjøgaard, Gisela; Rosendal, Lars; Kristiansen, Jesper

    2010-01-01

    The aim of this investigation was to study female workers active in the labour market for differences between those with trapezius myalgia (MYA) and without (CON) during repetitive pegboard (PEG) and stress (STR) tasks regarding (1) relative muscle load, (2) trapezius muscle blood flow, (3) metab...

  7. A RANDOMIZED TRIAL TO STUDY THE COMPARISON OF TRIGGER POINT DRY NEEDLING VERSUS KINESIO TAPING TECHNIQUE IN MYOFASCIAL PAIN SYNDROME DURING A 3-MONTH FOLLOW UP

    Directory of Open Access Journals (Sweden)

    Emrullah Hayta

    2016-10-01

    Full Text Available Background: Managemen of myofascial pain syndrome (MPS is a current research subject since there is a small number of randomized studies comparing different management techniques. Multiple studies attempted to assess various treatment options including trigger point dry needling and kinesiotaping. We compared the effects of trigger point dry needling and kinesiotaping in the management of myofascial pain syndome during a 3-month follow-up period. Methods: In this prospective randomized studyin MPS patients with upper trapezius muscle trigger points, the effects of dry needling (n=28 and kinesiotaping (n=27 was compared with regard to the visual analog scale (VAS, neck disability index (NDI, and Nottingham health profile (NHP scores measured at the weeks 0, 4, and 12. Results: Both dry needling and kinesiotaping comparably reduced VAS scores measured at the weeks 4 and 12 and their efficacies were more remarkable at the week 12 (p<0.05. These interventions significantly reduced the NDI and NHP score and their effects were also more remarkable at the week 12; however, dry needling was found more effective (p<0.05. Conclusion: Overall, in current clinical settings, during the management of MPS, pain can be reduced comparably by both dry needling and kinesiotaping; however, restriction in the range of motionin neck region and quality of life are more remarkably reduced by dry needling. Both dry needling and kinesiotaping can provide an increasing effectiveness up to 12 weeks.

  8. Experimental pain leads to reorganisation of trapezius electromyography during computer work with active and passive pauses

    DEFF Research Database (Denmark)

    Samani, Afshin; Holtermann, Andreas; Søgaard, Karen

    2009-01-01

    The aim of this laboratory study was to investigate acute effects of experimental muscle pain on spatial electromyographic (EMG) activity of the trapezius muscle during computer work with active and passive pauses. Twelve healthy male subjects performed four sessions of computer work for 2 min...... in one day, with passive (relax) and active (30% maximum voluntary contraction of shoulder elevation) pauses given every 40 s without and with presence of experimental pain. Surface EMG signals were recorded from four parts of the trapezius. The centroid of exposure variation analysis along the time axis...... was lower during computer work with active pauses when compared with passive one in all muscle parts (P

  9. Effects of eccentric exercise on trapezius electromyography during computer work with active and passive pauses

    DEFF Research Database (Denmark)

    Samani, Afshin; Holtermann, Andreas; Søgaard, Karen

    2009-01-01

    ) and active (30% maximum voluntary contraction of shoulder elevation) pauses given every 40s over 2 days, before, immediately and 24h after eccentric exercise. Surface EMG signals were recorded from four parts of the trapezius during computer work. FINDINGS: EMG amplitude during computer work decreased......BACKGROUND: The aim of this laboratory study was to investigate the effects of eccentric exercises on the trapezius muscle spatial electromyographic (EMG) activity during computer work with active and passive pauses. METHODS: Twelve healthy male subjects performed computer work with passive (relax...... immediately after exercise (Pwork with active pauses compared with passive ones (P

  10. Influence of power line harmonic radiation on the VLF wave activity in the upper ionosphere: Is it capable to trigger new emissions?

    Czech Academy of Sciences Publication Activity Database

    Němec, František; Parrot, M.; Santolík, Ondřej

    2010-01-01

    Roč. 115, - (2010), A11301/1-A11301/9 ISSN 0148-0227 R&D Projects: GA ČR GA205/09/1253; GA MŠk ME09107 Institutional research plan: CEZ:AV0Z30420517 Keywords : PLHR events * triggered emissions * DEMETER satellite Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.303, year: 2010

  11. Trigger finger

    Science.gov (United States)

    ... digit; Trigger finger release; Locked finger; Digital flexor tenosynovitis ... cut or hand Yellow or green drainage from the cut Hand pain or discomfort Fever If your trigger finger returns, call your surgeon. You may need another surgery.

  12. Myofascial trigger points, neck mobility, and forward head posture in episodic tension-type headache.

    Science.gov (United States)

    Fernández-de-Las-Peñas, César; Cuadrado, Maria L; Pareja, Juan A

    2007-05-01

    To assess the differences in the presence of trigger points (TrPs) in head and neck muscles, forward head posture (FHP) and neck mobility between episodic tension-type headache (ETTH) subjects and healthy controls. In addition, we assess the relationship between these muscle TrPs, FHP, neck mobility, and several clinical variables concerning the intensity and the temporal profile of headache. TTH is a headache in which musculoskeletal disorders of the craniocervical region might play an important role in its pathogenesis. Design.-A blinded, controlled pilot study. Fifteen ETTH subjects and 15 matched controls without headache were studied. TrPs in both upper trapezius, both sternocleidomastoids, and both temporalis muscles were identified according to Simons and Gerwin diagnostic criteria (tenderness in a hypersensible spot within a palpable taut band, local twitch response elicited by snapping palpation, and elicited referred pain with palpation). Side-view pictures of each subject were taken in both sitting and standing positions, in order to assess FHP by measuring the craniovertebral angle. A cervical goniometer was employed to measure neck mobility. All measures were taken by a blinded assessor. A headache diary was kept for 4 weeks in order to assess headache intensity, frequency, and duration. The mean number of TrPs for each ETTH subject was 3.7 (SD: 1.3), of which 1.9 (SD: 0.9) were active, and 1.8 (SD: 0.9) were latent. Control subjects only had latent TrPs (mean: 1.5; SD: 1). TrP occurrence between the 2 groups was significantly different for active TrPs (P .05). Differences in the distribution of TrPs were significant for the right upper trapezius muscles (P= .04), the left sternocleidomastoid (P= .03), and both temporalis muscles (P < .001). Within the ETTH group, headache intensity, frequency, and duration outcomes did not differ depending on TrP activity, whether the TrP was active or latent. The craniovertebral angle was smaller, ie, there was a

  13. Development of fatigue and discomfort in the upper trapezius muscle during light manual work

    NARCIS (Netherlands)

    Bosch, T.; Looze, M.P. de; Dieën, J.H. van

    2007-01-01

    Optimization of the temporal aspects of task design requires a better understanding of the development of muscle fatigue in the neck and shoulder region over time. The objective of the study was to investigate this in two production companies and to determine the relationship between objective and

  14. Adaptations of upper trapezius muscle activity during sustained contractions in women with fibromyalgia

    DEFF Research Database (Denmark)

    Falla, Deborah Lorraine; Andersen, Helle; Danneskiold-Samsøe, Bente

    2010-01-01

    a topographical map of the distribution of muscle activity. The pain level rated by the patients at the beginning of the sustained contraction was 5.9+/-1.5. The peak pain intensity for the control group following the injection of hypertonic saline was 6.0+/-1.6. During the sustained contractions, the EMG...

  15. The effects of psychosocial factors on trapezius muscle activity levels during computer use

    NARCIS (Netherlands)

    Bruno Garza, Jennifer L.; Eijckelhof, Belinda H W; Huysmans, Maaike A.; Johnson, Peter W.; Van Dieen, Jaap H.; Van Der Beek, Allard J.; Dennerlein, Jack T.

    2012-01-01

    The goal of the present study, a part of the PROOF (Predicting Occupational biomechanics among OFfice workers) study, was to determine if there was a relationship between psychosocial stress, measured by reward and over-commitment, and trapezius muscle activity while workers performed their own

  16. Objective measurement of tissue tension in myofascial trigger point areas before and during the administration of anesthesia with complete blocking of neuromuscular transmission.

    Science.gov (United States)

    Buchmann, Johannes; Neustadt, Beate; Buchmann-Barthel, Katharina; Rudolph, Soeren; Klauer, Thomas; Reis, Olaf; Smolenski, Ulrich; Buchmann, Hella; Wagner, Klaus F; Haessler, Frank

    2014-03-01

    Myofascial trigger points (MTPs) are extremely frequent in the human musculoskeletal system. Despite this, little is known about their etiology. Increased muscular tension in the trigger point area could be a major factor for the development of MTPs. To investigate the impact of muscular tension in the taut band with an MTP and thereby, the spinal excitability of associated segmental neurons, we objectively measured the tissue tension in MTPs before and during the administration of anesthesia using a transducer. Three target muscles (m. temporalis, upper part of m. trapezius, and m. extensor carpi radialis longus) with an MTP and 1 control muscle without an MTP were examined in 62 patients scheduled for an operation. We found significant 2-way interactions (ANOVA, Pspinal segmental excitability. In line with this, we assume a predominant, but not unique, impact of increased spinal excitability resulting in an augmented tension of segmental-associated muscle fibers for the etiology of MTP. Consequently, postisometric relaxation might be a promising therapeutic option for MTPs.

  17. Myofascial trigger point-focused head and neck massage for recurrent tension-type headache: A randomized, placebo-controlled clinical trial

    Science.gov (United States)

    Moraska, Albert F.; Stenerson, Lea; Butryn, Nathan; Krutsch, Jason P.; Schmiege, Sarah J.; Mann, J. Douglas

    2014-01-01

    Objective Myofascial trigger points (MTrPs) are focal disruptions in skeletal muscle that can refer pain to the head and reproduce the pain patterns of tension-type headache (TTH). The present study applied massage focused on MTrPs of subjects with TTH in a placebo-controlled, clinical trial to assess efficacy on reducing headache pain. Methods Fifty-six subjects with TTH were randomized to receive 12 massage or placebo (detuned ultrasound) sessions over six weeks, or to wait-list. Trigger point release (TPR) massage focused on MTrPs in cervical musculature. Headache pain (frequency, intensity and duration) was recorded in a daily headache diary. Additional outcome measures included self-report of perceived clinical change in headache pain and pressure-pain threshold (PPT) at MTrPs in the upper trapezius and sub-occipital muscles. Results From diary recordings, group differences across time were detected in headache frequency (p=0.026), but not for intensity or duration. Post hoc analysis indicated headache frequency decreased from baseline for both massage (pheadache pain for massage than placebo or wait-list groups (p=0.002). PPT improved in all muscles tested for massage only (all p'streatment of TTH, and 2) TTH, like other chronic conditions, is responsive to placebo. Clinical trials on headache that do not include a placebo group are at risk for overestimating the specific contribution from the active intervention. PMID:25329141

  18. Surgical fasciectomy of the trapezius muscle combined with neurolysis of the Spinal accessory nerve; results and long-term follow-up in 30 consecutive cases of refractory chronic whiplash syndrome

    Directory of Open Access Journals (Sweden)

    Freeman Michael

    2010-04-01

    Full Text Available Abstract Background Chronic problems from whiplash trauma generally include headache, pain and neck stiffness that may prove refractory to conservative treatment modalities. As has previously been reported, such afflicted patients may experience significant temporary relief with injections of local anesthetic to painful trigger points in muscles of the shoulder and neck, or lasting symptomatic improvement through surgical excision of myofascial trigger points. In a subset of patients who present with chronic whiplash syndrome, the clinical findings suggest an affliction of the spinal accessory nerve (CN XI, SAN by entrapment under the fascia of the trapezius muscle. The present study was undertaken to assess the effectiveness of SAN neurolysis in chronic whiplash syndrome. Methods A standardized questionnaire and a linear visual-analogue scale graded 0-10 was used to assess disability related to five symptoms (pain, headache, insomnia, weakness, and stiffness before, and one year after surgery in a series of thirty consecutive patients. Results The preoperative duration of symptoms ranged from seven months to 13 years. The following changes in disability scores were documented one year after surgery: Overall pain decreased from 9.5 +/- 0.9 to 3.2 +/- 2.6 (p Conclusions Entrapment of the spinal accessory nerve and/or chronic compartment syndrome of the trapezius muscle may cause chronic debilitating pain after whiplash trauma, without radiological or electrodiagnostic evidence of injury. In such cases, surgical treatment may provide lasting relief.

  19. Trapezius Muscle Load, Heart Rate and Time Pressure during Day and Night Shift in Swiss and Japanese Nurses

    Science.gov (United States)

    NICOLETTI, Corinne; MÜLLER, Christian; TOBITA, Itoko; NAKASEKO, Masaru; LÄUBLI, Thomas

    2014-01-01

    The aim of the present study was to analyze the activity of the trapezius muscle, the heart rate and the time pressure of Swiss and Japanese nurses during day and night shifts. The parameters were measured during a day and a night shift of 17 Swiss and 22 Japanese nurses. The observed rest time of the trapezius muscle was longer for Swiss than for Japanese nurses during both shifts. The 10th and the 50th percentile of the trapezius muscle activity showed a different effect for Swiss than for Japanese nurses. It was higher during the day shift of Swiss nurses and higher during the night shift of Japanese nurses. Heart rate was higher for both Swiss and Japanese nurses during the day. The time pressure was significantly higher for Japanese than for Swiss nurses. Over the duration of the shifts, time pressure increased for Japanese nurses and slightly decreased for those from Switzerland. Considering trapezius muscle activity and time pressure, the nursing profession was more burdening for the examined Japanese nurses than for Swiss nurses. In particular, the night shift for Japanese nurses was characterized by a high trapezius muscle activity and only few rest times for the trapezius muscle. PMID:24633074

  20. Trapezius Muscle Activity in using Ordinary and Ergonomically Designed Dentistry Chairs

    Directory of Open Access Journals (Sweden)

    O Haddad

    2012-03-01

    Full Text Available Background: Most dentists complain of musculoskeletal disorders which can be caused by prolonged static posture, lack of suitable rest and other physical and psychological problems. Objective: We evaluated a chair with a new ergonomic design which incorporated forward leaning chest and arm supports. Methods: The chair was evaluated in the laboratory during task simulation and EMG analysis on 12 students and subjectively assessed by 30 professional dentists using an 18-item questionnaire. EMG activity of right and left trapezius muscles for 12 male students with no musculoskeletal disorders was measured while simulating common tasks like working on the teeth of the lower jaw. Results: Normalized EMG data showed significant reduction (p<0.05 in all EMG recordings of the trapezius muscle. Dentists also unanimously preferred the ergonomically designed chair. Conclusion: Such ergonomically designed chairs should be introduced as early as possible in student training before bad postural habits are acquired.

  1. Trigger Finger

    Science.gov (United States)

    ... in a bent position. People whose work or hobbies require repetitive gripping actions are at higher risk ... developing trigger finger include: Repeated gripping. Occupations and hobbies that involve repetitive hand use and prolonged gripping ...

  2. Chronic whiplash and central sensitization; an evaluation of the role of a myofascial trigger points in pain modulation

    Directory of Open Access Journals (Sweden)

    Freeman Michael D

    2009-04-01

    Full Text Available Abstract Objective it has been established that chronic neck pain following whiplash is associated with the phenomenon of central sensitization, in which injured and uninjured parts of the body exhibit lowered pain thresholds due to an alteration in central pain processing. it has furthermore been hypothesized that peripheral sources of nociception in the muscles may perpetuate central sensitization in chronic whiplash. the hypothesis explored in the present study was whether myofascial trigger points serve as a modulator of central sensitization in subjects with chronic neck pain. Design controlled case series. Setting outpatient chronic pain clinic. Subjects seventeen patients with chronic and intractable neck pain and 10 healthy controls without complaints of neck pain. Intervention symptomatic subjects received anesthetic infiltration of myofascial trigger points in the upper trapezius muscles and controls received the anesthetic in the thigh. Outcome measures: pre and post injection cervical range of motion, pressure pain thresholds (ppt over the infraspinatus, wrist extensor, and tibialis anterior muscles. sensitivity to light (photophobia and subjects' perception of pain using a visual analog scale (vas were also evaluated before and after injections. only the ppt was evaluated in the asymptomatic controls. Results immediate (within 1 minute alterations in cervical range of motion and pressure pain thresholds were observed following an average of 3.8 injections with 1–2 cc of 1% lidocaine into carefully identified trigger points. cervical range of motion increased by an average of 49% (p = 0.000 in flexion and 44% (p = 0.001 in extension, 47% (p = 0.000 and 28% (p Conclusion the present data suggest that myofascial trigger points serve to perpetuate lowered pain thresholds in uninjured tissues. additionally, it appears that lowered pain thresholds associated with central sensitization can be immediately reversed, even when associated

  3. Peripheral nerve stimulation (PNS) in the trapezius muscle region alleviate chronic neuropathic pain after lower brachial plexus root avulsion lesion: A case report

    DEFF Research Database (Denmark)

    Sørensen, Jens Christian Hedemann; Meier, Kaare; Perinpam, Larshan

    Peripheral nerve stimulation (PNS) in the trapezius muscle region alleviate chronic neuropathic pain after lower brachial plexus root avulsion lesion: A case report......Peripheral nerve stimulation (PNS) in the trapezius muscle region alleviate chronic neuropathic pain after lower brachial plexus root avulsion lesion: A case report...

  4. Triggering Artefacts

    DEFF Research Database (Denmark)

    Mogensen, Preben Holst; Robinson, Mike

    1995-01-01

    and adapting them to specific situations need not be ad hoc.Triggering artefacts are a way of systematically challenging both designers' preunderstandings and the conservatism of work practice. Experiences from the Great Belt tunnel and bridge project are used to illustrate howtriggering artefacts change...

  5. Distribution of myogenic progenitor cells and myonuclei is altered in women with vs. those without chronically painful trapezius muscle

    DEFF Research Database (Denmark)

    Mackey, Abigail; Andersen, Lars L; Frandsen, Ulrik

    2010-01-01

    It is hypothesized that repeated recruitment of low-threshold motor units is an underlying cause of chronic pain in trapezius myalgia. This study investigated the distribution of satellite cells (SCs), myonuclei, and macrophages in muscle biopsies from the trapezius muscle of 42 women performing...... repetitive manual work, diagnosed with trapezius myalgia (MYA; 44 ± 8 yr; mean ± SD) and 20 matched healthy controls (CON; 45 ± 9 yr). Our hypothesis was that muscle of MYA, in particular type I fibers, would demonstrate higher numbers of SCs, myonuclei, and macrophages compared with CON. SCs were identified...... was not in line with our hypothesis and suggests that the elevated SC content of MYA was not due to heightened inflammatory cell contents, but rather to provide new myonuclei. The findings of greater numbers of SCs in type I fibers of muscle subjected to repeated low-intensity work support our hypothesis...

  6. Immediate effects of plantar inputs on the upper half muscles and upright posture: a preliminary study.

    Science.gov (United States)

    Ciuffolo, Fabio; Ferritto, Anna L; Muratore, Filippo; Tecco, Simona; Testa, Mauro; D'Attilio, Michele; Festa, Felice

    2006-01-01

    This purpose of this study was to investigate the immediate effects of plantar inputs on both the upper half muscle activity (anterior temporal, masseter, digastric, sternocleidomastoid, upper and lower trapezius, cervical) and the body posture, by means of electromyography (EMG) and vertical force platform, respectively. Twenty four (24) healthy adults, between the ages of 24 and 31 years (25.3 +/- 1.9), with no history of craniomandibular disorder or systemic musculoskeletal dysfunction, were randomly divided into two groups: test group (fourteen subjects) and control group (ten subjects). A first recording session (TO) measured the baseline EMG and postural patterns of both groups. After this session, the test group wore test shoes with insoles that stimulated the plantar surfaces, while the control group wore placebo shoes. After one hour, a second set of measurements (T1) were performed. Significant differences between the groups at baseline were observed in the left anterior temporal, left cervical, and left upper trapezius, as well as at T1 in the left anterior temporal and right upper trapezius (p postural blindness in the test group compared to the control group was observed. Further studies are warranted to investigate the short and long-term effects of this type of insole, in patients with both craniomandibular-cervical and lower extremity disorders.

  7. Increased sternocleidomastoid, but not trapezius, muscle activity in response to increased chewing load.

    Science.gov (United States)

    Häggman-Henrikson, Birgitta; Nordh, Erik; Eriksson, Per-Olof

    2013-10-01

    Previous findings, during chewing, that boluses of larger size and harder texture result in larger amplitudes of both mandibular and head-neck movements suggest a relationship between increased chewing load and incremental recruitment of jaw and neck muscles. The present report evaluated jaw (masseter and digastric) and neck [sternocleidomastoid (SCM) and trapezius] muscle activity during the chewing of test foods of different sizes and textures by 10 healthy subjects. Muscle activity was recorded by surface electromyography and simultaneous mandibular and head movements were recorded using an optoelectronic technique. Each subject performed continuous jaw-opening/jaw-closing movements whilst chewing small and large boluses of chewing gum and rubber silicone (Optosil). For jaw opening/jaw closing without a bolus, SCM activity was recorded for jaw opening concomitantly with digastric activity. During chewing, SCM activity was recorded for jaw closing concomitantly with masseter activity. Trapezius activity was present in some, but not all, cycles. For the masseter and SCM muscles, higher activity was seen with larger test foods, suggesting increased demand and recruitment of these muscles in response to an increased chewing load. This result reinforces the previous notion of a close functional connection between the jaw and the neck motor systems in jaw actions and has scientific and clinical significance for studying jaw function and dysfunction. © 2013 Eur J Oral Sci.

  8. Effects of Temperature on Chronic Trapezius Myofascial Pain Syndrome during Dry Needling Therapy

    Directory of Open Access Journals (Sweden)

    Gang Wang

    2014-01-01

    Full Text Available The purpose of this study was to investigate the effects of temperature on chronic trapezius myofascial pain syndrome during dry needling therapy. Sixty patients were randomized into two groups of dry needling (DN alone (group A and DN combined with heat therapy group (group B. Each patient was treated once and the therapeutic effect was assessed by the visual analogue scale (VAS, pressure pain threshold (PPT, and the 36-item short form health survey (SF-36 at seven days, one month, and three months after treatment. Evaluation based on VAS and PPT showed that the pain of patients in groups A and B was significantly (P<0.05 relieved at seven days, one month, and three months after treatment Compared to before treatment. There was significantly (P<0.05 less pain in group B than group A at one and three months after treatment. The SF-36 evaluation demonstrated that the physical condition of patients in both groups showed significant (P<0.05 improvement at one month and three months after treatment than before treatment. Our study suggests that both DN and DN heating therapy were effective in the treatment of trapezius MPS, and that DN heating therapy had better long-term effects than DN therapy.

  9. Association between Neck/Shoulder Pain and Trapezius Muscle Tenderness in Office Workers

    DEFF Research Database (Denmark)

    Brandt, Mikkel; Sundstrup, Emil; Jakobsen, Markus D.

    2014-01-01

    workers. Methods. 653 employees from two large office workplaces in Copenhagen, Denmark, replied to a questionnaire on health and working conditions (mean: age 43 years, body mass index 24 kg⋅m−2, computer use 90% of work time, 73% women). Respondents rated intensity of neck/shoulder pain during...... for age, gender, and chronic disease. Results.The prevalence of “no,” “some,” and “severe” tenderness of the trapeziusmuscle was 18%, 59%, and 23% in women and 51%, 42%, and 7%inmen, respectively (chi-square, P Participants with “no,” “some,” and “severe” tenderness of the trapezius muscle......, respectively, rated their neck/shoulder pain intensity to 1.5 (SD 1.6), 3.8 (SD 2.0), and 5.7 (SD 1.9) for women and 1.4 (SD 1.4), 3.1 (SD 2.2), and 5.1 (SD 1.7) for men. For every unit increase in neck/shoulder pain intensity, the OR for one unit increase in trapezius tenderness was 1.86 (95% confidence...

  10. A case of radiation ulcer of the neck treated by a lower trapezius myocutaneous flap

    International Nuclear Information System (INIS)

    Shimbashi, Takeshi; Satomi, Takao; Okuyama, Toshio.

    1981-01-01

    A case of radiation ulcer of the neck is reported. The patient is a 50-year-old male. He had been treated for a malignant parotid tumor 12 years earlier. Extirpation of the tumor and radical neck disection had been performed and after the operation he received radiation therapy. On 1979, erosion appeared and developed into an ulcer. On October 14, massive hemorrhage and cardiac arrest suddenly occurred. Immediate emergency treatment was administered and he was resuscitated. He was admitted to our division for the reconstruction of his ulcer. The operation was successfully performed on his ulcer using a lower trapezius myocutaneous flap. He has been followed up for 9 months. The effect of the operation is esthetically and functionally satisfactory. (author)

  11. MANFAAT TEKNIK RELAKSASI MASSAGE MUSCULLUS TRAPEZIUS DENGAN AROMATERAPI MAWAR TERHADAP PERUBAHAN TEKANAN DARAH PADA IBU HAMIL

    Directory of Open Access Journals (Sweden)

    Ernawati Ernawati

    2017-02-01

    Full Text Available Hipertensi dalam kehamilan merupakan 5-5% penyulit kehamilan dan merupakan salah satu dari tiga penyebab tertinggi mortalitas dan morbiditas ibu bersalin di Indonesia. Terdapat 2 cara mengatasi hipertensi yang dapat dilakukan yaitu secara farmakologis dan non farmakologis. Beberapa jenis penanganan non farmakologi yang dapat dilakukan adalah akupresur (akupuntur tanpa jarum, terapi herbal, terapi jus, pijat (massage, yoga, aromaterapi, pernafasan dan relaksasi, meditasi, hypnosis dan perawatan dirumah. Tujuan penelitian ini adalah untuk mengetahui manfaat teknik relaksasi massage muscullus trapezius dengan aromaterapi mawar terhadap perubahan tekanan darah pada ibu hamil. Penelitian ini menggunakan rancangan kuantitatif dengan pendekatan cross sectional. Subyek dalam penelitian ini berjumlah 38 ibu hamil. Penelitian yang dilakukan di RSUD Hj. Anna Lasmanah Banjarnegara periode 4 Januari sampai 19 Februari 2016. Teknik pengambilan sampel dalam penelitian ini adalah Purposive Sampling. Data diperoleh melalui observasi langsung. Analisis data dilakukan dengan rumus t-test of related menggunakan pengolahan komputerisasi statiscal product and serve solution (SPSS 17. Hasil analisis data didapatkan nilai thitung sebesar 9,932 untuk tekanan darah sistol dan thitung 6,173 untuk tekanan darah diastole. Jika df=38-1=37 dan ?=0,05 maka didapatkan ttabel 2,042. thitung ? ttabel maka Ho diterima, Ha ditolak dan jika t hitung ? t tabel maka Ho ditolak, Ha diterima. Dalam uji hipotesis didapatkan t hitung ? t table (9,932>2,042 dan (6,173>2,042, maka dapat disimpulkan bahwa Ho ditolak dan Ha diterima. Maka terdapat manfaat teknik relaksasi massage muscullus trapezius dengan aromaterapi mawar terhadap perubahan tekanan darah pada ibu hamil.

  12. Trigger circuit

    International Nuclear Information System (INIS)

    Verity, P.R.; Chaplain, M.D.; Turner, G.D.J.

    1984-01-01

    A monostable trigger circuit comprises transistors TR2 and TR3 arranged with their collectors and bases interconnected. The collector of the transistor TR2 is connected to the base of transistor TR3 via a capacitor C2 the main current path of a grounded base transistor TR1 and resistive means R2,R3. The collector of transistor TR3 is connected to the base of transistor TR2 via resistive means R6, R7. In the stable state all the transistors are OFF, the capacitor C2 is charged, and the output is LOW. A positive pulse input to the base of TR2 switches it ON, which in turn lowers the voltage at points A and B and so switches TR1 ON so that C2 can discharge via R2, R3, which in turn switches TR3 ON making the output high. Thus all three transistors are latched ON. When C2 has discharged sufficiently TR1 switches OFF, followed by TR3 (making the output low again) and TR2. The components C1, C3 and R4 serve to reduce noise, and the diode D1 is optional. (author)

  13. Short-term changes in neck pain, widespread pressure pain sensitivity, and cervical range of motion after the application of trigger point dry needling in patients with acute mechanical neck pain: a randomized clinical trial.

    Science.gov (United States)

    Mejuto-Vázquez, María J; Salom-Moreno, Jaime; Ortega-Santiago, Ricardo; Truyols-Domínguez, Sebastián; Fernández-de-Las-Peñas, César

    2014-04-01

    Randomized clinical trial. To determine the effects of trigger point dry needling (TrPDN) on neck pain, widespread pressure pain sensitivity, and cervical range of motion in patients with acute mechanical neck pain and active trigger points in the upper trapezius muscle. TrPDN seems to be effective for decreasing pain in individuals with upper-quadrant pain syndromes. Potential effects of TrPDN for decreasing pain and sensitization in individuals with acute mechanical neck pain are needed. Methods Seventeen patients (53% female) were randomly assigned to 1 of 2 groups: a single session of TrPDN or no intervention (waiting list). Pressure pain thresholds over the C5-6 zygapophyseal joint, second metacarpal, and tibialis anterior muscle; neck pain intensity; and cervical spine range-of-motion data were collected at baseline (pretreatment) and 10 minutes and 1 week after the intervention by an assessor blinded to the treatment allocation of the patient. Mixed-model analyses of variance were used to examine the effects of treatment on each outcome variable. Patients treated with 1 session of TrPDN experienced greater decreases in neck pain, greater increases in pressure pain threshold, and higher increases in cervical range of motion than those who did not receive an intervention at both 10 minutes and 1 week after the intervention (Ppain intensity and widespread pressure pain sensitivity, and also increase active cervical range of motion, in patients with acute mechanical neck pain. Changes in pain, pressure pain threshold, and cervical range of motion surpassed their respective minimal detectable change values, supporting clinically relevant treatment effects. Level of Evidence Therapy, level 1b-.

  14. Pressure pain threshold changes after repeated mechano-nociceptive stimulation of the trapezius muscle: possible influence of previous pain experience

    DEFF Research Database (Denmark)

    Sjölund, Bengt H; Persson, Ann L

    2007-01-01

    or an increase. Normalized data, transformed into mean unidirectional PPT differences, showed statistically highly significant changes after intervention. The relative risk of reacting with lowered PPTs on noxious stimulation was 3.7 times higher for subjects who had not given birth to children than for subjects...... over 1 trapezius muscle (skin anaesthetized) in 27 healthy women before and after the intervention. With a mean stimulation rate of 0.40 Hz and a mean nociceptive stimulation intensity of 1.78 x Threshold, subjects were found to systematically react with a change in PPT, either a decrease...... who had given birth to 1 or several children (Pstimulation of the trapezius muscle in healthy females evokes moderate and temporary...

  15. Physical workload, trapezius muscle activity, and neck pain in nurses' night and day shifts: a physiological evaluation.

    Science.gov (United States)

    Nicoletti, Corinne; Spengler, Christina M; Läubli, Thomas

    2014-05-01

    The purpose of this study was to compare physical workload, electromyography (EMG) of the trapezius muscle, neck pain and mental well-being at work between night and day shifts in twenty Swiss nurses. Work pulse (average increase of heart rate over resting heart rate) was lower during night (27 bpm) compared to day shifts (34 bpm; p night (82% of average) compared to day shifts (110%; p night shifts. Trapezius muscle rest time was longer during night (13% of shift duration) than day shifts (7%; p night shifts. Neck pain and mental well-being at work were similar between shifts. Subjective perception of burden was similar between shifts despite less physical burden at night, suggesting there are other contributing factors. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. Responses of algesic and metabolic substances to 8h of repetitive manual work in myalgic human trapezius muscle

    DEFF Research Database (Denmark)

    Larsson, B.; Rosendal, L.; Kristiansen, J.

    2008-01-01

    The trapezius muscle often develops pain as the result of repetitive and stressful work tasks although it is unclear to what extent this pain is due to alterations in muscle concentrations of algesic/nociceptive substances. Twenty women with chronic neck- and shoulder pain (TM) whose work required...... highly repetitive work tasks and 20 pain-free female colleagues (CON) were studied during and after a full 8-hour workday. We collected microdialysates from their dominant/most painful trapezius muscle; concentrations of serotonin, glutamate, lactate, pyruvate, potassium, bradykinin, and cytokines...... muscles. TM had higher concentrations of glutamate (71+/-42 vs. 36+/-15mumoll(-1)) and pyruvate (187+/-89 vs. 125+/-63mumoll(-1)) than CON. Interstitial serotonin was higher in TM (before work: 10.6+/-10.8 vs. 2.2+/-1.2nM; after work: 9.2+/-8.3 vs. 1.5+/-2.9nM). The trapezius blood flow during the working...

  17. Complete acromioclavicular joint dislocation treated with reconstructed ligament by trapezius muscle fascia and observation of fascial metaplasia.

    Science.gov (United States)

    Wang, Chaoliang; Huang, Sufang; Wang, Yingzhen; Sun, Xuesheng; Zhu, Tao; Li, Qiang; Lin, Chu

    2015-01-01

    We evaluated the long-term clinical results of acute complete acromioclavicular dislocations treated by reconstruction of the acromioclavicular and coracoclavicular ligament using trapezius muscle fascia. Open reduction and internal fixation was performed using the clavicular hook plate in 12 patients with acute complete acromioclavicular joint dislocation, and the acromioclavicular and coracoclavicular ligaments were reconstructed using trapezius muscle fascia. Radiographic evaluations were conducted postoperatively. We evaluated the functional results with constant scoring system and radiological results at the final follow-up visit. The mean Constant score at the final follow-up visit was 91.67 (range, 81 to 100). The results were excellent in eight patients (66.7%) and good in four patients (33.3%). Three patients with scores from 80 to 90 had mild pain during activity, but this did not affect the range of motion of the shoulder. All patients have returned to their preoperative work without any limitations. Compared with the contralateral side, radiography showed anatomical reposition in the vertical plane in all cases. The hook-plate fixation with ligament reconstruction was successful in treating AC dislocations. The acromioclavicular and coracoclavicular ligament were reconstructed by trapezius muscle fascia that keep the distal clavicle stable both vertically and horizontally after type III injuries.

  18. Complete acromioclavicular joint dislocation treated with reconstructed ligament by trapezius muscle fascia and observation of fascial metaplasia

    Directory of Open Access Journals (Sweden)

    Wang Chaoliang

    2015-01-01

    Full Text Available We evaluated the long-term clinical results of acute complete acromioclavicular dislocations treated by reconstruction of the acromioclavicular and coracoclavicular ligament using trapezius muscle fascia. Open reduction and internal fixation was performed using the clavicular hook plate in 12 patients with acute complete acromioclavicular joint dislocation, and the acromioclavicular and coracoclavicular ligaments were reconstructed using trapezius muscle fascia. Radiographic evaluations were conducted postoperatively. We evaluated the functional results with constant scoring system and radiological results at the final follow-up visit. The mean Constant score at the final follow-up visit was 91.67 (range, 81 to 100. The results were excellent in eight patients (66.7% and good in four patients (33.3%. Three patients with scores from 80 to 90 had mild pain during activity, but this did not affect the range of motion of the shoulder. All patients have returned to their preoperative work without any limitations. Compared with the contralateral side, radiography showed anatomical reposition in the vertical plane in all cases. The hook-plate fixation with ligament reconstruction was successful in treating AC dislocations. The acromioclavicular and coracoclavicular ligament were reconstructed by trapezius muscle fascia that keep the distal clavicle stable both vertically and horizontally after type III injuries.

  19. The LHCb trigger

    International Nuclear Information System (INIS)

    Korolko, I.

    1998-01-01

    This paper describes progress in the development of the LHCb trigger system since the letter of intent. The trigger philosophy has significantly changed, resulting in an increase of trigger efficiency for signal B events. It is proposed to implement a level-1 vertex topology trigger in specialised hardware. (orig.)

  20. A Novel in situ Trigger Combination Method

    International Nuclear Information System (INIS)

    Buzatu, Adrian; Warburton, Andreas; Krumnack, Nils; Yao, Wei-Ming

    2012-01-01

    Searches for rare physics processes using particle detectors in high-luminosity colliding hadronic beam environments require the use of multi-level trigger systems to reject colossal background rates in real time. In analyses like the search for the Higgs boson, there is a need to maximize the signal acceptance by combining multiple different trigger chains when forming the offline data sample. In such statistically limited searches, datasets are often amassed over periods of several years, during which the trigger characteristics evolve and their performance can vary significantly. Reliable production cross-section measurements and upper limits must take into account a detailed understanding of the effective trigger inefficiency for every selected candidate event. We present as an example the complex situation of three trigger chains, based on missing energy and jet energy, to be combined in the context of the search for the Higgs (H) boson produced in association with a W boson at the Collider Detector at Fermilab (CDF). We briefly review the existing techniques for combining triggers, namely the inclusion, division, and exclusion methods. We introduce and describe a novel fourth in situ method whereby, for each candidate event, only the trigger chain with the highest a priori probability of selecting the event is considered. The in situ combination method has advantages of scalability to large numbers of differing trigger chains and of insensitivity to correlations between triggers. We compare the inclusion and in situ methods for signal event yields in the CDF WH search.

  1. Measurement of muscle thickness of the serratus anterior and lower trapezius using ultrasound imaging in competitive recreational adult swimmers, with and without current shoulder pain.

    Science.gov (United States)

    McKenna, Leanda J; de Ronde, Mandy; Le, Minyang; Burke, William; Graves, Anna; Williams, Sian A

    2018-02-01

    To compare serratus anterior and lower trapezius muscle thickness between swimmers with and without current shoulder pain, and between sides when measured by real-time ultrasound imaging. A single blinded age and gender-matched case-control study with 26 symptomatic and 26 asymptomatic recreational swimmers. Muscle thickness of serratus anterior and lower trapezius were measured using previously validated real-time ultrasound imaging protocols. Serratus anterior thickness was measured in side lying with 90° of glenohumeral flexion at rest and during a scapular protraction contraction. Lower trapezius thickness was measured in prone with 145° of glenohumeral abduction whilst at rest and when holding the weight of the arm. There was no statistically significant difference between the muscle thickness of serratus anterior and lower trapezius between the symptomatic shoulder and the dominance-matched shoulder in the asymptomatic group of swimmers. There was also no significant difference in muscle thickness between the symptomatic side and asymptomatic side within the symptomatic group. There appears to be no difference in serratus anterior and lower trapezius thickness between swimmers who have mild to moderate shoulder pain, who continue to swim and those who do not have shoulder pain. When imaging the serratus anterior and lower trapezius in swimmers with mild shoulder pain, clinicians should expect no differences between sides. If muscle thickness differences between sides are detected in recreational swimmers, this may indicate that the swimmer is participating in other asymmetrical activities or has a higher level of shoulder pain. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. The Central Trigger Processor (CTP)

    CERN Multimedia

    Franchini, Matteo

    2016-01-01

    The Central Trigger Processor (CTP) receives trigger information from the calorimeter and muon trigger processors, as well as from other sources of trigger. It makes the Level-1 decision (L1A) based on a trigger menu.

  3. Referred pain from myofascial trigger points in head and neck-shoulder muscles reproduces head pain features in children with chronic tension type headache.

    Science.gov (United States)

    Fernández-de-las-Peñas, César; Fernández-Mayoralas, Daniel M; Ortega-Santiago, Ricardo; Ambite-Quesada, Silvia; Palacios-Ceña, Domingo; Pareja, Juan A

    2011-02-01

    Our aim was to describe the referred pain pattern and areas from trigger points (TrPs) in head, neck, and shoulder muscles in children with chronic tension type headache (CTTH). Fifty children (14 boys, 36 girls, mean age: 8 ± 2) with CTTH and 50 age- and sex- matched children participated. Bilateral temporalis, masseter, superior oblique, upper trapezius, sternocleidomastoid, suboccipital, and levator scapula muscles were examined for TrPs by an assessor blinded to the children's condition. TrPs were identified with palpation and considered active when local and referred pains reproduce headache pain attacks. The referred pain areas were drawn on anatomical maps, digitalized, and also measured. The total number of TrPs was significantly greater in children with CTTH as compared to healthy children (P < 0.001). Active TrPs were only present in children with CTTH (P < 0.001). Within children with CTTH, a significant positive association between the number of active TrPs and headache duration (r (s) = 0.315; P = 0.026) was observed: the greater the number of active TrPs, the longer the duration of headache attack. Significant differences in referred pain areas between groups (P < 0.001) and muscles (P < 0.001) were found: the referred pain areas were larger in CTTH children (P < 0.001), and the referred pain area elicited by suboccipital TrPs was larger than the referred pain from the remaining TrPs (P < 0.001). Significant positive correlations between some headache clinical parameters and the size of the referred pain area were found. Our results showed that the local and referred pains elicited from active TrPs in head, neck and shoulder shared similar pain pattern as spontaneous CTTH in children, supporting a relevant role of active TrPs in CTTH in children.

  4. Spatial distribution of surface EMG on trapezius and lumbar muscles of violin and cello players in single note playing.

    Science.gov (United States)

    Afsharipour, Babak; Petracca, Francesco; Gasparini, Mauro; Merletti, Roberto

    2016-12-01

    Musicians activate their muscles in different patterns, depending on their posture, the instrument being played, and their experience level. Bipolar surface electrodes have been used in the past to monitor such activity, but this method is highly sensitive to the location of the electrode pair. In this work, the spatial distribution of surface EMG (sEMG) of the right trapezius and right and left erector spinae muscles were studied in 16 violin players and 11 cello players. Musicians played their instrument one string at a time in sitting position with/without backrest support. A 64 sEMG electrode (16×4) grid, 10mm inter-electrode distance (IED), was placed over the middle and lower trapezius (MT and LT) of the bowing arm. Two 16×2 electrode grids (IED=10mm) were placed on the left and right erector spinae muscles. Subjects played each of the four strings of the instrument either in large (1bow/s) or detaché tip/tail (8bows/s) bowing in two sessions (two days). In each of two days, measurements were repeated after half an hour of exercise to see the effect of exercise on the muscle activity and signal stability. A "muscle activity index" (MAI) was defined as the spatial average of the segmented active region of the RMS map. Spatial maps were automatically segmented using the watershed algorithm and thresholding. Results showed that, for violin players, sliding the bow upward from the tip toward the tail results in a higher MAI for the trapezius muscle than a downward bow. On the contrary, in cello players, higher MAI is produced in the tail to tip movement. For both instruments, an increasing MAI in the trapezius was observed as the string position became increasingly lateral, from string 1 (most medial) toward string 4 (most lateral). Half an hour of performance did not cause significant differences between the signal quality and the MAI values measured before and after the exercise. The MAI of the left and right erector spinae was smaller in the case of

  5. Topographical and functional anatomy of trapezius muscle innervation by spinal accessory nerve and C2 to C4 nerves of cervical plexus.

    Science.gov (United States)

    Gavid, M; Mayaud, A; Timochenko, A; Asanau, A; Prades, J M

    2016-10-01

    The aim of this study was to determine the existence and the frequency of communicating branches between the spinal accessory nerve (SAN) and the C2, C3 and C4 roots of the cervical plexus. The present study also aimed to elucidate whether these branches contain motor fibers or not. Dissection of the cervical region was performed on twelve adult cadavers. A powered operating microscope was necessary to dissect the SAN and its branches and also to dissect C2, C3 and C4 nerve branches. In a second step, data from 13 patients who underwent 25 modified neck dissections under trapezius muscle's monitoring were collected. At the end of surgery, intraoperative stimulation on the SAN, C2, C3 and C4 nerve branches was performed. Registered potentials in the three parts of the trapezius muscle, using the NIM Medtronic system, were analyzed. During cadaver dissection, 18 (78 %) communicating branches were identified between the SAN and C2, 11 (48 %) between the SAN and C3, 12 (52 %) between the SAN and C4. Intraoperative stimulation of the SAN and its branch for the trapezius muscle provided a significant electroneurographic response in the three parts of the trapezius muscle in all subjects. Intraoperative stimulation of C3 led to recordable contractions of the trapezius muscle in 5 (20 %) modified neck surgeries, stimulation of C4 led to recordable contractions during 5 (20 %) modified neck dissections. One case of contraction was recorded after intraoperative stimulation of C2 (7 %). Although we were able to identify at least one communicating branch between the SAN and the roots of the cervical plexus in each cadaver dissection, the cervical plexus is not always involved in trapezius motor innervation. Intraoperative electroneurography demonstrated that a motor input from the cervical plexus to the trapezius muscle was provided in only 32 % of cases. Therefore, SAN trunk and C3-C4 roots should be carefully preserved during modified neck dissection to protect

  6. Resting mechanomyographic amplitude for the erector spinae and trapezius muscles following resistance exercise in a healthy population

    International Nuclear Information System (INIS)

    Wages, Nathan P; Beck, Travis W; Ye, Xin; Hofford, Craig W

    2013-01-01

    Musculoskeletal disorders are some of the most commonly occurring chronic conditions affecting the US population, with the most self-reported and diagnosed disorder being low back pain. Low back pain is often due to suboptimal back muscle function, at least in part, as a result of muscle inactivity and disuse. Resistance exercise has been shown to be successful in the treatment of low back pain. The purpose of the present investigation was to examine resting mechanomyographic (MMG) amplitude for the erector spinae and trapezius muscles prior to and following resistance exercise. Twenty healthy, college-aged men were measured for resting MMG amplitude levels prior to, and following a resistance training workout. The workout consisted of three sets of ten repetitions on the conventional deadlift, bent-over row, and lat pulldown exercises, with 1 min of rest between all sets and exercises. The results showed that there were approximate 10% and 15% decreases in normalized MMG amplitude after exercise for the erector spinae and trapezius muscles, respectively. These findings demonstrate a relaxation effect in the back muscles after exercise that could potentially be helpful in alleviating low back pain. (paper)

  7. Experience of Percutaneous Trigger Finger Release under Local ...

    African Journals Online (AJOL)

    Background: Trigger finger is a common disorder of upper extremity. Majority of the patients can be treated conservatively but some resistant cases eventually need surgery. Aim: The aim of this study is to evaluate the results of percutaneous trigger finger release under local anesthesia. Subjects and Methods: This is a ...

  8. Selective activation of intra-muscular compartments within the trapezius muscle in subjects with Subacromial Impingement Syndrome. A case-control study

    DEFF Research Database (Denmark)

    Larsen, C M; Juul-Kristensen, B; Olsen, H B

    2014-01-01

    Neuromuscular control of the scapular muscles is important in the etiology of shoulder pain. Electromyographical (EMG) biofeedback in healthy people has been shown to support a selective activation of the lower compartment of the trapezius muscle, specifically. The aim of the present paper was to...

  9. BAT Triggering Performance

    Science.gov (United States)

    McLean, Kassandra M.; Fenimore, E. E.; Palmer, D. M.; BAT Team

    2006-09-01

    The Burst Alert Telescope (BAT) onboard Swift has detected and located about 160 gamma-ray bursts (GRBs) in its first twenty months of operation. BAT employs two triggering systems to find GRBs: image triggering, which looks for a new point source in the field of view, and rate triggering, which looks for a significant increase in the observed counts. The image triggering system looks at 1 minute, 5 minute, and full pointing accumulations of counts in the detector plane in the energy range of 15-50 keV, with about 50 evaluations per pointing (about 40 minutes). The rate triggering system looks through 13 different time scales (from 4ms to 32s), 4 overlapping energy bins (covering 15-350 keV), 9 regions of the detector plane (from the full plane to individual quarters), and two background sampling models to search for GRBs. It evaluates 27000 trigger criteria in a second, for close to 1000 criteria. The image triggering system looks at 1, 5, and 40 minute accumulations of counts in the detector plane in the energy range of 15-50 keV. Both triggering systems are working very well with the settings from before launch and after we turned on BAT. However, we now have more than a year and a half of data to evaluate these triggering systems and tweak them for optimal performance, as well as lessons learned from these triggering systems.

  10. Stay away from asthma triggers

    Science.gov (United States)

    Asthma triggers - stay away from; Asthma triggers - avoiding; Reactive airway disease - triggers; Bronchial asthma - triggers ... clothes. They should leave the coat outside or away from your child. Ask people who work at ...

  11. Specific proteins of the trapezius muscle correlate with pain intensity and sensitivity – an explorative multivariate proteomic study of the trapezius muscle in women with chronic widespread pain

    Directory of Open Access Journals (Sweden)

    Olausson P

    2016-06-01

    Full Text Available Patrik Olausson, Bijar Ghafouri, Nazdar Ghafouri, Björn Gerdle Pain and Rehabilitation Centre, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden Abstract: Chronic widespread pain (CWP including fibromyalgia syndrome (FMS has a high prevalence and is associated with prominent negative consequences. CWP/FMS exhibits morphological and functional alterations in the central nervous system. The importance of peripheral factors for maintaining the central alterations are under debate. In this study, the proteins from biopsies of the trapezius muscle from 18 female CWP/FMS patients and 19 healthy female controls were analyzed. Pain intensity and pressure pain thresholds (PPT over the trapezius muscles were registered. Twelve proteins representing five different groups of proteins were important regressors of pain intensity in CWP/FMS (R2=0.99; P<0.001. In the regression of PPT in CWP/FMS, it was found that 16 proteins representing six groups of proteins were significant regressors (R2=0.95, P<0.05. Many of the important proteins were stress and inflammation proteins, enzymes involved in metabolic pathways, and proteins associated with muscle damage, myopathies, and muscle recovery. The altered expression of these proteins may reflect both direct and indirect nociceptive/inflammatory processes as well as secondary changes. The relative importance of the identified proteins and central alterations in CWP need to be investigated in future research. Data from this and the previous study concerning the same cohorts give support to the suggestion that peripheral factors are of importance for maintaining pain aspects in CWP/FMS. Keywords: chronic widespread pain, proteomics, biomarkers, multivariate data analysis, pain threshold, numeric rating scale

  12. Lessons from (triggered) tremor

    Science.gov (United States)

    Gomberg, Joan

    2010-01-01

    I test a “clock-advance” model that implies triggered tremor is ambient tremor that occurs at a sped-up rate as a result of loading from passing seismic waves. This proposed model predicts that triggering probability is proportional to the product of the ambient tremor rate and a function describing the efficacy of the triggering wave to initiate a tremor event. Using data mostly from Cascadia, I have compared qualitatively a suite of teleseismic waves that did and did not trigger tremor with ambient tremor rates. Many of the observations are consistent with the model if the efficacy of the triggering wave depends on wave amplitude. One triggered tremor observation clearly violates the clock-advance model. The model prediction that larger triggering waves result in larger triggered tremor signals also appears inconsistent with the measurements. I conclude that the tremor source process is a more complex system than that described by the clock-advance model predictions tested. Results of this and previous studies also demonstrate that (1) conditions suitable for tremor generation exist in many tectonic environments, but, within each, only occur at particular spots whose locations change with time; (2) any fluid flow must be restricted to less than a meter; (3) the degree to which delayed failure and secondary triggering occurs is likely insignificant; and 4) both shear and dilatational deformations may trigger tremor. Triggered and ambient tremor rates correlate more strongly with stress than stressing rate, suggesting tremor sources result from time-dependent weakening processes rather than simple Coulomb failure.

  13. Triggering trigeminal neuralgia

    DEFF Research Database (Denmark)

    Di Stefano, Giulia; Maarbjerg, Stine; Nurmikko, Turo

    2018-01-01

    Introduction Although it is widely accepted that facial pain paroxysms triggered by innocuous stimuli constitute a hallmark sign of trigeminal neuralgia, very few studies to date have systematically investigated the role of the triggers involved. In the recently published diagnostic classification...

  14. Triggering the GRANDE array

    International Nuclear Information System (INIS)

    Wilson, C.L.; Bratton, C.B.; Gurr, J.; Kropp, W.; Nelson, M.; Sobel, H.; Svoboda, R.; Yodh, G.; Burnett, T.; Chaloupka, V.; Wilkes, R.J.; Cherry, M.; Ellison, S.B.; Guzik, T.G.; Wefel, J.; Gaidos, J.; Loeffler, F.; Sembroski, G.; Goodman, J.; Haines, T.J.; Kielczewska, D.; Lane, C.; Steinberg, R.; Lieber, M.; Nagle, D.; Potter, M.; Tripp, R.

    1990-01-01

    A brief description of the Gamma Ray And Neutrino Detector Experiment (GRANDE) is presented. The detector elements and electronics are described. The trigger logic for the array is then examined. The triggers for the Gamma Ray and the Neutrino portions of the array are treated separately. (orig.)

  15. Trigger Menu in 2017

    CERN Document Server

    The ATLAS collaboration

    2018-01-01

    This document summarises the trigger menu deployed by the ATLAS experiment during 2017 data taking at proton-proton collision centre-of-mass energies of $\\sqrt{s}=13$ TeV and $\\sqrt{s}=5$ TeV at the LHC and describes the improvements with respect to the trigger system and menu used in 2016 data taking.

  16. Causality and headache triggers

    Science.gov (United States)

    Turner, Dana P.; Smitherman, Todd A.; Martin, Vincent T.; Penzien, Donald B.; Houle, Timothy T.

    2013-01-01

    Objective The objective of this study was to explore the conditions necessary to assign causal status to headache triggers. Background The term “headache trigger” is commonly used to label any stimulus that is assumed to cause headaches. However, the assumptions required for determining if a given stimulus in fact has a causal-type relationship in eliciting headaches have not been explicated. Methods A synthesis and application of Rubin’s Causal Model is applied to the context of headache causes. From this application the conditions necessary to infer that one event (trigger) causes another (headache) are outlined using basic assumptions and examples from relevant literature. Results Although many conditions must be satisfied for a causal attribution, three basic assumptions are identified for determining causality in headache triggers: 1) constancy of the sufferer; 2) constancy of the trigger effect; and 3) constancy of the trigger presentation. A valid evaluation of a potential trigger’s effect can only be undertaken once these three basic assumptions are satisfied during formal or informal studies of headache triggers. Conclusions Evaluating these assumptions is extremely difficult or infeasible in clinical practice, and satisfying them during natural experimentation is unlikely. Researchers, practitioners, and headache sufferers are encouraged to avoid natural experimentation to determine the causal effects of headache triggers. Instead, formal experimental designs or retrospective diary studies using advanced statistical modeling techniques provide the best approaches to satisfy the required assumptions and inform causal statements about headache triggers. PMID:23534872

  17. The LHCb trigger

    CERN Document Server

    Hernando Morata, Jose Angel

    2006-01-01

    The LHCb experiment relies on an efficient trigger to select a rate up to 2 kHz of events useful for physics analysis from an initial rate of 10 MHz of visible collisions. In this contribution, we describe the different LHCb trigger algorithms and present their expected performance.

  18. The NA27 trigger

    International Nuclear Information System (INIS)

    Bizzarri, R.; Di Capua, E.; Falciano, S.; Iori, M.; Marel, G.; Piredda, G.; Zanello, L.; Haupt, L.; Hellman, S.; Holmgren, S.O.; Johansson, K.E.

    1985-05-01

    We have designed and implemented a minimum bias trigger together with a fiducial volume trigger for the experiment NA27, performed at the CERN SPS. A total of more than 3 million bubble chamber pictures have been taken with a triggered cross section smaller than 75% of the total inelastic cross section. Events containing charm particles were triggered with an efficiency of 98 +2 sub(-3)%. With the fiducial volume trigger, the probability for a picture to contain an interaction in the visible hydrogen increased from 47.3% to 59.5%, reducing film cost and processing effort with about 20%. The improvement in data taking rate is shown to be negligible. (author)

  19. LHCb Topological Trigger Reoptimization

    International Nuclear Information System (INIS)

    Likhomanenko, Tatiana; Khairullin, Egor; Rogozhnikov, Alex; Ustyuzhanin, Andrey; Ilten, Philip; Williams, Michael

    2015-01-01

    The main b-physics trigger algorithm used by the LHCb experiment is the so- called topological trigger. The topological trigger selects vertices which are a) detached from the primary proton-proton collision and b) compatible with coming from the decay of a b-hadron. In the LHC Run 1, this trigger, which utilized a custom boosted decision tree algorithm, selected a nearly 100% pure sample of b-hadrons with a typical efficiency of 60-70%; its output was used in about 60% of LHCb papers. This talk presents studies carried out to optimize the topological trigger for LHC Run 2. In particular, we have carried out a detailed comparison of various machine learning classifier algorithms, e.g., AdaBoost, MatrixNet and neural networks. The topological trigger algorithm is designed to select all ’interesting” decays of b-hadrons, but cannot be trained on every such decay. Studies have therefore been performed to determine how to optimize the performance of the classification algorithm on decays not used in the training. Methods studied include cascading, ensembling and blending techniques. Furthermore, novel boosting techniques have been implemented that will help reduce systematic uncertainties in Run 2 measurements. We demonstrate that the reoptimized topological trigger is expected to significantly improve on the Run 1 performance for a wide range of b-hadron decays. (paper)

  20. NOMAD Trigger Studies

    International Nuclear Information System (INIS)

    Varvell, K.

    1995-01-01

    The author reports on the status of an offline study of the NOMAD triggers, which has several motivations. Of primary importance is to demonstrate, using offline information recorded by the individual subdetectors comprising NOMAD, that the online trigger system is functioning as expected. Such an investigation serves to complement the extensive monitoring which is already carried out online. More specific to the needs of the offline software and analysis, the reconstruction of tracks and vertices in the detector requires some knowledge of the time at which the trigger has occurred, in order to locate relevant hits in the drift chambers and muon chambers in particular. The fact that the different triggers allowed by the MIOTRINO board take varying times to form complicates this task. An offline trigger algorithm may serve as a tool to shed light on situations where the online trigger status bits have not been recorded correctly, as happens in a small number of cases, or as an aid to studies with the aim of further refinement of the online triggers themselves

  1. Calorimetry triggering in ATLAS

    CERN Document Server

    Igonkina, O; Adragna, P; Aharrouche, M; Alexandre, G; Andrei, V; Anduaga, X; Aracena, I; Backlund, S; Baines, J; Barnett, B M; Bauss, B; Bee, C; Behera, P; Bell, P; Bendel, M; Benslama, K; Berry, T; Bogaerts, A; Bohm, C; Bold, T; Booth, J R A; Bosman, M; Boyd, J; Bracinik, J; Brawn, I, P; Brelier, B; Brooks, W; Brunet, S; Bucci, F; Casadei, D; Casado, P; Cerri, A; Charlton, D G; Childers, J T; Collins, N J; Conde Muino, P; Coura Torres, R; Cranmer, K; Curtis, C J; Czyczula, Z; Dam, M; Damazio, D; Davis, A O; De Santo, A; Degenhardt, J; Delsart, P A; Demers, S; Demirkoz, B; Di Mattia, A; Diaz, M; Djilkibaev, R; Dobson, E; Dova, M, T; Dufour, M A; Eckweiler, S; Ehrenfeld, W; Eifert, T; Eisenhandler, E; Ellis, N; Emeliyanov, D; Enoque Ferreira de Lima, D; Faulkner, P J W; Ferland, J; Flacher, H; Fleckner, J E; Flowerdew, M; Fonseca-Martin, T; Fratina, S; Fhlisch, F; Gadomski, S; Gallacher, M P; Garitaonandia Elejabarrieta, H; Gee, C N P; George, S; Gillman, A R; Goncalo, R; Grabowska-Bold, I; Groll, M; Gringer, C; Hadley, D R; Haller, J; Hamilton, A; Hanke, P; Hauser, R; Hellman, S; Hidvgi, A; Hillier, S J; Hryn'ova, T; Idarraga, J; Johansen, M; Johns, K; Kalinowski, A; Khoriauli, G; Kirk, J; Klous, S; Kluge, E-E; Koeneke, K; Konoplich, R; Konstantinidis, N; Kwee, R; Landon, M; LeCompte, T; Ledroit, F; Lei, X; Lendermann, V; Lilley, J N; Losada, M; Maettig, S; Mahboubi, K; Mahout, G; Maltrana, D; Marino, C; Masik, J; Meier, K; Middleton, R P; Mincer, A; Moa, T; Monticelli, F; Moreno, D; Morris, J D; Mller, F; Navarro, G A; Negri, A; Nemethy, P; Neusiedl, A; Oltmann, B; Olvito, D; Osuna, C; Padilla, C; Panes, B; Parodi, F; Perera, V J O; Perez, E; Perez Reale, V; Petersen, B; Pinzon, G; Potter, C; Prieur, D P F; Prokishin, F; Qian, W; Quinonez, F; Rajagopalan, S; Reinsch, A; Rieke, S; Riu, I; Robertson, S; Rodriguez, D; Rogriquez, Y; Rhr, F; Saavedra, A; Sankey, D P C; Santamarina, C; Santamarina Rios, C; Scannicchio, D; Schiavi, C; Schmitt, K; Schultz-Coulon, H C; Schfer, U; Segura, E; Silverstein, D; Silverstein, S; Sivoklokov, S; Sjlin, J; Staley, R J; Stamen, R; Stelzer, J; Stockton, M C; Straessner, A; Strom, D; Sushkov, S; Sutton, M; Tamsett, M; Tan, C L A; Tapprogge, S; Thomas, J P; Thompson, P D; Torrence, E; Tripiana, M; Urquijo, P; Urrejola, P; Vachon, B; Vercesi, V; Vorwerk, V; Wang, M; Watkins, P M; Watson, A; Weber, P; Weidberg, T; Werner, P; Wessels, M; Wheeler-Ellis, S; Whiteson, D; Wiedenmann, W; Wielers, M; Wildt, M; Winklmeier, F; Wu, X; Xella, S; Zhao, L; Zobernig, H; de Seixas, J M; dos Anjos, A; Asman, B; Özcan, E

    2009-01-01

    The ATLAS experiment is preparing for data taking at 14 TeV collision energy. A rich discovery physics program is being prepared in addition to the detailed study of Standard Model processes which will be produced in abundance. The ATLAS multi-level trigger system is designed to accept one event in 2 105 to enable the selection of rare and unusual physics events. The ATLAS calorimeter system is a precise instrument, which includes liquid Argon electro-magnetic and hadronic components as well as a scintillator-tile hadronic calorimeter. All these components are used in the various levels of the trigger system. A wide physics coverage is ensured by inclusively selecting events with candidate electrons, photons, taus, jets or those with large missing transverse energy. The commissioning of the trigger system is being performed with cosmic ray events and by replaying simulated Monte Carlo events through the trigger and data acquisition system.

  2. BTeV Trigger

    International Nuclear Information System (INIS)

    Gottschalk, Erik E.

    2006-01-01

    BTeV was designed to conduct precision studies of CP violation in BB-bar events using a forward-geometry detector in a hadron collider. The detector was optimized for high-rate detection of beauty and charm particles produced in collisions between protons and antiprotons. The trigger was designed to take advantage of the main difference between events with beauty and charm particles and more typical hadronic events-the presence of detached beauty and charm decay vertices. The first stage of the BTeV trigger was to receive data from a pixel vertex detector, reconstruct tracks and vertices for every beam crossing, reject at least 98% of beam crossings in which neither beauty nor charm particles were produced, and trigger on beauty events with high efficiency. An overview of the trigger design and its evolution to include commodity networking and computing components is presented

  3. Calorimetry triggering in ATLAS

    International Nuclear Information System (INIS)

    Igonkina, O; Achenbach, R; Andrei, V; Adragna, P; Aharrouche, M; Bauss, B; Bendel, M; Alexandre, G; Anduaga, X; Aracena, I; Backlund, S; Bogaerts, A; Baines, J; Barnett, B M; Bee, C; P, Behera; Bell, P; Benslama, K; Berry, T; Bohm, C

    2009-01-01

    The ATLAS experiment is preparing for data taking at 14 TeV collision energy. A rich discovery physics program is being prepared in addition to the detailed study of Standard Model processes which will be produced in abundance. The ATLAS multi-level trigger system is designed to accept one event in 2 | 10 5 to enable the selection of rare and unusual physics events. The ATLAS calorimeter system is a precise instrument, which includes liquid Argon electro-magnetic and hadronic components as well as a scintillator-tile hadronic calorimeter. All these components are used in the various levels of the trigger system. A wide physics coverage is ensured by inclusively selecting events with candidate electrons, photons, taus, jets or those with large missing transverse energy. The commissioning of the trigger system is being performed with cosmic ray events and by replaying simulated Monte Carlo events through the trigger and data acquisition system.

  4. Calorimetry Triggering in ATLAS

    International Nuclear Information System (INIS)

    Igonkina, O.; Achenbach, R.; Adragna, P.; Aharrouche, M.; Alexandre, G.; Andrei, V.; Anduaga, X.; Aracena, I.; Backlund, S.; Baines, J.; Barnett, B.M.; Bauss, B.; Bee, C.; Behera, P.; Bell, P.; Bendel, M.; Benslama, K.; Berry, T.; Bogaerts, A.; Bohm, C.; Bold, T.; Booth, J.R.A.; Bosman, M.; Boyd, J.; Bracinik, J.; Brawn, I.P.; Brelier, B.; Brooks, W.; Brunet, S.; Bucci, F.; Casadei, D.; Casado, P.; Cerri, A.; Charlton, D.G.; Childers, J.T.; Collins, N.J.; Conde Muino, P.; Coura Torres, R.; Cranmer, K.; Curtis, C.J.; Czyczula, Z.; Dam, M.; Damazio, D.; Davis, A.O.; De Santo, A.; Degenhardt, J.

    2011-01-01

    The ATLAS experiment is preparing for data taking at 14 TeV collision energy. A rich discovery physics program is being prepared in addition to the detailed study of Standard Model processes which will be produced in abundance. The ATLAS multi-level trigger system is designed to accept one event in 2/10 5 to enable the selection of rare and unusual physics events. The ATLAS calorimeter system is a precise instrument, which includes liquid Argon electro-magnetic and hadronic components as well as a scintillator-tile hadronic calorimeter. All these components are used in the various levels of the trigger system. A wide physics coverage is ensured by inclusively selecting events with candidate electrons, photons, taus, jets or those with large missing transverse energy. The commissioning of the trigger system is being performed with cosmic ray events and by replaying simulated Monte Carlo events through the trigger and data acquisition system.

  5. Calorimetry triggering in ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Igonkina, O [Nikhef National Institute for Subatomic Physics, Amsterdam (Netherlands); Achenbach, R; Andrei, V [Kirchhoff Institut fuer Physik, Universitaet Heidelberg, Heidelberg (Germany); Adragna, P [Physics Department, Queen Mary, University of London, London (United Kingdom); Aharrouche, M; Bauss, B; Bendel, M [Institut fr Physik, Universitt Mainz, Mainz (Germany); Alexandre, G [Section de Physique, Universite de Geneve, Geneva (Switzerland); Anduaga, X [Universidad Nacional de La Plata, La Plata (Argentina); Aracena, I [Stanford Linear Accelerator Center (SLAC), Stanford (United States); Backlund, S; Bogaerts, A [European Laboratory for Particle Physics (CERN), Geneva (Switzerland); Baines, J; Barnett, B M [STFC Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, Oxon (United Kingdom); Bee, C [Centre de Physique des Particules de Marseille, IN2P3-CNRS, Marseille (France); P, Behera [Iowa State University, Ames, Iowa (United States); Bell, P [School of Physics and Astronomy, University of Manchester, Manchester (United Kingdom); Benslama, K [University of Regina, Regina (Canada); Berry, T [Department of Physics, Royal Holloway and Bedford New College, Egham (United Kingdom); Bohm, C [Fysikum, Stockholm University, Stockholm (Sweden)

    2009-04-01

    The ATLAS experiment is preparing for data taking at 14 TeV collision energy. A rich discovery physics program is being prepared in addition to the detailed study of Standard Model processes which will be produced in abundance. The ATLAS multi-level trigger system is designed to accept one event in 2 | 10{sup 5} to enable the selection of rare and unusual physics events. The ATLAS calorimeter system is a precise instrument, which includes liquid Argon electro-magnetic and hadronic components as well as a scintillator-tile hadronic calorimeter. All these components are used in the various levels of the trigger system. A wide physics coverage is ensured by inclusively selecting events with candidate electrons, photons, taus, jets or those with large missing transverse energy. The commissioning of the trigger system is being performed with cosmic ray events and by replaying simulated Monte Carlo events through the trigger and data acquisition system.

  6. LHCb Topological Trigger Reoptimization

    CERN Document Server

    INSPIRE-00400931; Ilten, Philip; Khairullin, Egor; Rogozhnikov, Alex; Ustyuzhanin, Andrey; Williams, Michael

    2015-12-23

    The main b-physics trigger algorithm used by the LHCb experiment is the so-called topological trigger. The topological trigger selects vertices which are a) detached from the primary proton-proton collision and b) compatible with coming from the decay of a b-hadron. In the LHC Run 1, this trigger, which utilized a custom boosted decision tree algorithm, selected a nearly 100% pure sample of b-hadrons with a typical efficiency of 60-70%; its output was used in about 60% of LHCb papers. This talk presents studies carried out to optimize the topological trigger for LHC Run 2. In particular, we have carried out a detailed comparison of various machine learning classifier algorithms, e.g., AdaBoost, MatrixNet and neural networks. The topological trigger algorithm is designed to select all "interesting" decays of b-hadrons, but cannot be trained on every such decay. Studies have therefore been performed to determine how to optimize the performance of the classification algorithm on decays not used in the training. ...

  7. Topological Trigger Developments

    CERN Multimedia

    Likhomanenko, Tatiana

    2015-01-01

    The main b-physics trigger algorithm used by the LHCb experiment is the so-called topological trigger. The topological trigger selects vertices which are a) detached from the primary proton-proton collision and b) compatible with coming from the decay of a b-hadron. In the LHC Run 1, this trigger utilized a custom boosted decision tree algorithm, selected an almost 100% pure sample of b-hadrons with a typical efficiency of 60-70%, and its output was used in about 60% of LHCb papers. This talk presents studies carried out to optimize the topological trigger for LHC Run 2. In particular, we have carried out a detailed comparison of various machine learning classifier algorithms, e.g., AdaBoost, MatrixNet and uBoost. The topological trigger algorithm is designed to select all "interesting" decays of b-hadrons, but cannot be trained on every such decay. Studies have therefore been performed to determine how to optimize the performance of the classification algorithm on decays not used in the training. These inclu...

  8. CMS Trigger Performance

    CERN Document Server

    Donato, Silvio

    2017-01-01

    During its second run of operation (Run 2) which started in 2015, the LHC will deliver a peak instantaneous luminosity that may reach $2 \\cdot 10^{34}$ cm$^{-2}$s$^{-1}$ with an average pile-up of about 55, far larger than the design value. Under these conditions, the online event selection is a very challenging task. In CMS, it is realized by a two-level trigger system the Level-1 (L1) Trigger, implemented in custom-designed electronics, and the High Level Trigger (HLT), a streamlined version of the offline reconstruction software running on a computer farm. In order to face this challenge, the L1 trigger has been through a major upgrade compared to Run 1, whereby all electronic boards of the system have been replaced, allowing more sophisticated algorithms to be run online. Its last stage, the global trigger, is now able to perform complex selections and to compute high-level quantities, like invariant masses. Likewise, the algorithms that run in the HLT go through big improvements; in particular, new appr...

  9. The ATLAS Tau Trigger

    CERN Document Server

    Dam, M; The ATLAS collaboration

    2009-01-01

    The ATLAS experiment at CERN’s LHC has implemented a dedicated tau trigger system to select hadronically decaying tau leptons from the enormous background of QCD jets. This promises a significant increase in the discovery potential to the Higgs boson and in searches for physics beyond the Standard Model. The three level trigger system has been optimised for effciency and good background rejection. The first level uses information from the calorimeters only, while the two higher levels include also information from the tracking detectors. Shower shape variables and the track multiplicity are important variables to distinguish taus from QCD jets. At the initial lumonosity of 10^31 cm^−2 s^−1, single tau triggers with a transverse energy threshold of 50 GeV or higher can be run standalone. Below this level, the tau signatures will be combined with other event signature

  10. The ATLAS Tau Trigger

    CERN Document Server

    Rados, PK; The ATLAS collaboration

    2014-01-01

    Physics processes involving tau leptons play a crucial role in understanding particle physics at the high energy frontier. The ability to efficiently trigger on events containing hadronic tau decays is therefore of particular importance to the ATLAS experiment. During the 2012 run, the Large Hadronic Collder (LHC) reached instantaneous luminosities of nearly $10^{34} cm^{-2}s^{-1}$ with bunch crossings occurring every $50 ns$. This resulted in a huge event rate and a high probability of overlapping interactions per bunch crossing (pile-up). With this in mind it was necessary to design an ATLAS tau trigger system that could reduce the event rate to a manageable level, while efficiently extracting the most interesting physics events in a pile-up robust manner. In this poster the ATLAS tau trigger is described, its performance during 2012 is presented, and the outlook for the LHC Run II is briefly summarized.

  11. ALICE High Level Trigger

    CERN Multimedia

    Alt, T

    2013-01-01

    The ALICE High Level Trigger (HLT) is a computing farm designed and build for the real-time, online processing of the raw data produced by the ALICE detectors. Events are fully reconstructed from the raw data, analyzed and compressed. The analysis summary together with the compressed data and a trigger decision is sent to the DAQ. In addition the reconstruction of the events allows for on-line monitoring of physical observables and this information is provided to the Data Quality Monitor (DQM). The HLT can process event rates of up to 2 kHz for proton-proton and 200 Hz for Pb-Pb central collisions.

  12. Trigger and decision processors

    International Nuclear Information System (INIS)

    Franke, G.

    1980-11-01

    In recent years there have been many attempts in high energy physics to make trigger and decision processes faster and more sophisticated. This became necessary due to a permanent increase of the number of sensitive detector elements in wire chambers and calorimeters, and in fact it was possible because of the fast developments in integrated circuits technique. In this paper the present situation will be reviewed. The discussion will be mainly focussed upon event filtering by pure software methods and - rather hardware related - microprogrammable processors as well as random access memory triggers. (orig.)

  13. The STAR trigger

    International Nuclear Information System (INIS)

    Bieser, F.S.; Crawford, H.J.; Engelage, J.; Eppley, G.; Greiner, L.C.; Judd, E.G.; Klein, S.R.; Meissner, F.; Minor, R.; Milosevich, Z.; Mutchler, G.; Nelson, J.M.; Schambach, J.; VanderMolen, A.S.; Ward, H.; Yepes, P.

    2003-01-01

    We describe the trigger system that we designed and implemented for the STAR detector at RHIC. This is a 10 MHz pipelined system based on fast detector output that controls the event selection for the much slower tracking detectors. Results from the first run are presented and new detectors for the 2001 run are discussed

  14. Asthma Triggers: Gain Control

    Science.gov (United States)

    ... harm people too. Try to use pest management methods that pose less of a risk. Keep counters, sinks, tables and floors clean and ... with pest challenges in your home and other environments. [EPA ... pests while reducing pesticide risks; roaches are often asthma triggers and shouldn’t ...

  15. Physics issues on triggering

    Indian Academy of Sciences (India)

    The detectors at the ILC are planned to run without hardware trigger. The ... as not coming from the interaction point and not matching to the silicon detectors ... electrons so that additional dE/dx cuts can help, making also here a factor 10 or.

  16. AIDS radio triggers.

    Science.gov (United States)

    Elias, A M

    1991-07-01

    In April 1991, the Ethnic Communities' Council of NSW was granted funding under the Community AIDS Prevention and Education Program through the Department of Community Services and Health, to produce a series of 6x50 second AIDS radio triggers with a 10-second tag line for further information. The triggers are designed to disseminate culturally-sensitive information about HIV/AIDS in English, Italian, Greek, Spanish, Khmer, Turkish, Macedonian, Serbo-Croatian, Arabic, Cantonese, and Vietnamese, with the goal of increasing awareness and decreasing the degree of misinformation about HIV/AIDS among people of non-English-speaking backgrounds through radio and sound. The 6 triggers cover the denial that AIDS exists in the community, beliefs that words and feelings do not protect one from catching HIV, encouraging friends to be compassionate, compassion within the family, AIDS information for a young audience, and the provision of accurate and honest information on HIV/AIDS. The triggers are slated to be completed by the end of July 1991 and will be broadcast on all possible community, ethnic, and commercial radio networks across Australia. They will be available upon request in composite form with an information kit for use by health care professionals and community workers.

  17. Dealing with Asthma Triggers

    Science.gov (United States)

    ... one trigger that you shouldn't avoid because exercise is important for your health. Your doctor will want you to be active, so talk with him or her about what to do before playing ... or 15 minutes before you exercise or play sports. And, of course, you'll ...

  18. Trigger Finger (Stenosing Tenosynovitis)

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Trigger Finger Email to a friend * required fields ...

  19. The ATLAS Tau Trigger

    International Nuclear Information System (INIS)

    Rados, Petar Kevin

    2013-06-01

    The tau lepton plays a crucial role in understanding particle physics at the Tera scale. One of the most promising probes of the Higgs boson coupling to fermions is with detector signatures involving taus. In addition, many theories beyond the Standard Model, such as supersymmetry and exotic particles (W' and Z'), predict new physics with large couplings to taus. The ability to trigger on hadronic tau decays is therefore critical to achieving the physics goals of the ATLAS experiment. The higher instantaneous luminosities of proton-proton collisions achieved by the Large Hadron Collider (LHC) in 2012 resulted in a larger probability of overlap (pile-up) between bunch crossings, and so it was critical for ATLAS to have an effective tau trigger strategy. The details of this strategy are summarized in this paper, and the results of the latest performance measurements are presented. (authors)

  20. The LPS trigger system

    International Nuclear Information System (INIS)

    Benotto, F.; Costa, M.; Staiano, A.; Zampieri, A.; Bollito, M.; Isoardi, P.; Pernigotti, E.; Sacchi, R.; Trapani, P.P.; Larsen, H.; Massam, T.; Nemoz, C.

    1996-03-01

    The Leading Proton Spectrometer (LPS) has been equipped with microstrip silicon detectors specially designed to trigger events with high values of x L vertical stroke anti p' p vertical stroke / vertical stroke anti p p vertical stroke ≥0.95 where vertical stroke anti p' p vertical stroke and vertical stroke anti p p vertical stroke are respectively the momenta of outgoing and incoming protons. The LPS First Level Trigger can provide a clear tag for very high momentum protons in a kinematical region never explored before. In the following we discuss the physics motivation in tagging very forward protons and present a detailed description of the detector design, the front end electronics, the readout electronics, the Monte Carlo simulation and some preliminary results from 1995 data taking. (orig.)

  1. Minimum risk trigger indices

    International Nuclear Information System (INIS)

    Tingey, F.H.

    1979-01-01

    A viable safeguards system includes among other things the development and use of indices which trigger various courses of action. The usual limit of error calculation provides such an index. The classical approach is one of constructing tests which, under certain assumptions, make the likelihood of a false alarm small. Of concern also is the test's failure to indicate a loss (diversion) when in fact one has occurred. Since false alarms are usually costly and losses both costly and of extreme strategic sinificance, there remains the task of balancing the probability of false alarm and its consequences against the probability of undetected loss and its consequences. The application of other than classical hypothesis testing procedures are considered in this paper. Using various consequence models, trigger indices are derived which have certain optimum properties. Application of the techniques would enhance the material control function

  2. Neural networks for triggering

    International Nuclear Information System (INIS)

    Denby, B.; Campbell, M.; Bedeschi, F.; Chriss, N.; Bowers, C.; Nesti, F.

    1990-01-01

    Two types of neural network beauty trigger architectures, based on identification of electrons in jets and recognition of secondary vertices, have been simulated in the environment of the Fermilab CDF experiment. The efficiencies for B's and rejection of background obtained are encouraging. If hardware tests are successful, the electron identification architecture will be tested in the 1991 run of CDF. 10 refs., 5 figs., 1 tab

  3. The ARGUS vertex trigger

    International Nuclear Information System (INIS)

    Koch, N.; Kolander, M.; Kolanoski, H.; Siegmund, T.; Bergter, J.; Eckstein, P.; Schubert, K.R.; Waldi, R.; Imhof, M.; Ressing, D.; Weiss, U.; Weseler, S.

    1995-09-01

    A fast second level trigger has been developed for the ARGUS experiment which recognizes tracks originating from the interaction region. The processor compares the hits in the ARGUS Micro Vertex Drift Chamber to 245760 masks stored in random access memories. The masks which are fully defined in three dimensions are able to reject tracks originating in the wall of the narrow beampipe of 10.5 mm radius. (orig.)

  4. PREVALENCE OF UPPER CROSS SYNDROME AMONG THE MEDICAL STUDENTS OF UNIVERSITY OF LAHORE

    Directory of Open Access Journals (Sweden)

    Iqra Mubeen

    2016-06-01

    Full Text Available Background: Upper cross syndrome is becoming more prevalent in today’s population. The syndrome is expressed as a postural disorder presenting with over active pectoralis musculature and upper trapezius musculature. Also there is inhibition of lower and middle trapezius musculature, which results in winging of scapula, elevated and abducted scapula. This scapulardyskinesia there by resulted inrounding of shoulders. The syndrome is often associated with bad posture in routine life oroccupation of a person.The purpose of the study is to determine the prevalence of upper cross syndrome in medical students of Lahore. Methods: A convenience sample of 384 medical students was selected from university of Lahore, based on inclusion and exclusion criteria. Medical students of age between 17 to 2 years with sound physical and mental state were included. Students with any trauma, recent injury, recent fracture or surgery and any serious underlying pathology that may interfere with mobility of upper limb were excluded from the study. The research was a cross sectional observational study and self-administered questionnaires were circulated among participants and the data was analyzed using SPSS version 21. Reed-co scale was used to analyze the proper alignment of head, neck and shoulder; where as wall push test was used to assess the abnormal protrusion of scapula. Results: The study have revealed that48.7% population of the students haveneck pain;and the results have concluded that high prevalence of upper cross syndrome in medical students of university of Lahore and a 66.8% of population was found to have poor studying posture. Conclusion: In this study relation between upper cross syndrome and bad posture were seen and it was found that the individuals suffering with upper cross syndrome were somehow related to bad posture or indulge in activities which make individual to adopt a posture of high physiologic cost there by leading to muscular imbalance

  5. High levels of N-palmitoylethanolamide and N-stearoylethanolamide in microdialysate samples from myalgic trapezius muscle in women.

    Directory of Open Access Journals (Sweden)

    Nazdar Ghafouri

    Full Text Available BACKGROUND: N-acylethanolamines (NAEs are endogenous compounds that regulate inflammation and pain. These include the cannabinoid ligand anandamide (AEA and the peroxisome proliferator-activated receptor-α ligand palmitoylethanolamide (PEA. Little is known as to the levels of NAEs in pain states in human, particularly in the skeletal muscle. The aim of this study was to investigate the levels of these lipid mediators in muscle dialysate from women with chronic neck-/shoulder pain compared to healthy controls. METHODS: Eleven women with chronic neck-/shoulder pain and eleven healthy women participated in this study. All participants went through microdialysis procedures in the trapezius muscle. Muscle dialysate samples were collected during four hours and analysed by nano liquid chromatography tandem mass spectrometry (nLC-MS/MS. RESULTS: We were able to detect AEA, PEA, N-stearoylethanolamine (SEA and 2-arachidonoylglycerol (2-AG in a single chromatographic run. Of the NAEs studied, PEA and SEA were clearly detectable in the muscle microdialysate samples. The muscle dialysate levels of PEA and SEA were significantly higher in myalgic subjects compared to healthy controls. CONCLUSION: This study demonstrates that microdialysis in combination with mass spectrometry can be used for analysing NAE's in human muscle tissue regularly over time. Furthermore the significant group differences in the concentration of PEA and SEA in this study might fill an important gap in our knowledge of mechanisms in chronic myalgia in humans. In the long run this expanded understanding of nociceptive and anitinociceptive processes in the muscle may provide a base for ameliorating treatment and rehabilitation of pain.

  6. Comparison of trapezius squeeze test and jaw thrust as clinical indicators for laryngeal mask airway insertion in spontaneously breathing children

    Science.gov (United States)

    Dinesh Kumar, K. K.; Bhardwaj, Neerja; Yaddanapudi, Sandhya

    2017-01-01

    Background and Aims: It is not known whether trapezius squeeze test (TPZ) is a better clinical test than jaw thrust (JT) to assess laryngeal mask airway (LMA) insertion conditions in children under sevoflurane anesthesia. Material and Methods: After the Institutional Ethics Committee approval and written informed parental consent, 124 American Society of Anesthesiologists I and II children of 2–8 years of age undergoing minor surgical procedures were randomized into TPZ and JT groups. The children were induced with 8% sevoflurane in oxygen at a fresh gas flow of 4 L/min. TPZ or JT was performed after 1 min of start of sevoflurane and then every 20 s till the test was negative, when end-tidal (ET) sevoflurane concentration was noted. Classic LMA of requisite size was inserted by a blinded anesthetist and conditions at the insertion of LMA, insertion time, and the number of attempts of LMA insertion were recorded. Results: The mean LMA insertion time was significantly longer (P < 0.001) for TPZ (145 ± 28.7 sec) compared to JT group (111.8 ± 31.0 sec). ET sevoflurane concentration at the time of LMA insertion was comparable in the two groups. LMA insertion conditions were similar in the two groups. There was no difference between the two groups regarding total number of attempts of LMA insertion. Heart rate (HR) decreased in both groups after LMA insertion (P < 0.001) but TPZ group had significantly lower HR compared with the JT group up to 5 min after LMA insertion (P = 0.03). Conclusion: Both JT and TPZ are equivalent clinical indicators in predicting the optimal conditions of LMA insertion in spontaneously breathing children; however, it takes a longer time to achieve a negative TPZ squeeze test. PMID:28413275

  7. Zinc triggers microglial activation.

    Science.gov (United States)

    Kauppinen, Tiina M; Higashi, Youichirou; Suh, Sang Won; Escartin, Carole; Nagasawa, Kazuki; Swanson, Raymond A

    2008-05-28

    Microglia are resident immune cells of the CNS. When stimulated by infection, tissue injury, or other signals, microglia assume an activated, "ameboid" morphology and release matrix metalloproteinases, reactive oxygen species, and other proinflammatory factors. This innate immune response augments host defenses, but it can also contribute to neuronal death. Zinc is released by neurons under several conditions in which microglial activation occurs, and zinc chelators can reduce neuronal death in animal models of cerebral ischemia and neurodegenerative disorders. Here, we show that zinc directly triggers microglial activation. Microglia transfected with a nuclear factor-kappaB (NF-kappaB) reporter gene showed a severalfold increase in NF-kappaB activity in response to 30 microm zinc. Cultured mouse microglia exposed to 15-30 microm zinc increased nitric oxide production, increased F4/80 expression, altered cytokine expression, and assumed the activated morphology. Zinc-induced microglial activation was blocked by inhibiting NADPH oxidase, poly(ADP-ribose) polymerase-1 (PARP-1), or NF-kappaB activation. Zinc injected directly into mouse brain induced microglial activation in wild-type mice, but not in mice genetically lacking PARP-1 or NADPH oxidase activity. Endogenous zinc release, induced by cerebral ischemia-reperfusion, likewise induced a robust microglial reaction, and this reaction was suppressed by the zinc chelator CaEDTA. Together, these results suggest that extracellular zinc triggers microglial activation through the sequential activation of NADPH oxidase, PARP-1, and NF-kappaB. These findings identify a novel trigger for microglial activation and a previously unrecognized mechanism by which zinc may contribute to neurological disorders.

  8. ATLAS Tau Trigger

    CERN Document Server

    Belanger-Champagne, C; Bosman, M; Brenner, R; Casado, MP; Czyczula, Z; Dam, M; Demers, S; Farrington, S; Igonkina, O; Kalinowski, A; Kanaya, N; Osuna, C; Pérez, E; Ptacek, E; Reinsch, A; Saavedra, A; Sopczak, A; Strom, D; Torrence, E; Tsuno, S; Vorwerk, V; Watson, A; Xella, S

    2008-01-01

    Moving to the high energy scale of the LHC, the identification of tau leptons will become a necessary and very powerful tool, allowing a discovery of physics beyond Standard Model. Many models, among them light SM Higgs and various SUSY models, predict an abundant production of taus with respect to other leptons. The reconstruction of hadronic tau decays, although a very challenging task in hadronic enviroments, allows to increase a signal efficiency by at least of factor 2, and provides an independent control sample to disantangle lepton tau decays from prompt electrons and muons. Thanks to the advanced calorimetry and tracking, the ATLAS experiment has developed tools to efficiently identify hadronic taus at the trigger level. In this presentation we will review the characteristics of taus and the methods to suppress low-multiplicity, low-energy jets contributions as well as we will address the tau trigger chain which provide a rejection rate of 10^5. We will further present plans for commissioning the ATLA...

  9. The D0 calorimeter trigger

    International Nuclear Information System (INIS)

    Guida, J.

    1992-12-01

    The D0 calorimeter trigger system consists of many levels to make physics motivated trigger decisions. The Level-1 trigger uses hardware techniques to reduce the trigger rate from ∼ 100kHz to 200Hz. It forms sums of electromagnetic and hadronic energy, globally and in towers, along with finding the missing transverse energy. A minimum energy is set on these energy sums to pass the event. The Level-2 trigger is a set of software filters, operating in a parallel-processing microvax farm which further reduces the trigger rate to a few Hertz. These filters will reject events which lack electron candidates, jet candidates, or missing transverse energy in the event. The performance of these triggers during the early running of the D0 detector will also be discussed

  10. Surgery for trigger finger.

    Science.gov (United States)

    Fiorini, Haroldo Junior; Tamaoki, Marcel Jun; Lenza, Mário; Gomes Dos Santos, Joao Baptista; Faloppa, Flávio; Belloti, Joao Carlos

    2018-02-20

    Trigger finger is a common clinical disorder, characterised by pain and catching as the patient flexes and extends digits because of disproportion between the diameter of flexor tendons and the A1 pulley. The treatment approach may include non-surgical or surgical treatments. Currently there is no consensus about the best surgical treatment approach (open, percutaneous or endoscopic approaches). To evaluate the effectiveness and safety of different methods of surgical treatment for trigger finger (open, percutaneous or endoscopic approaches) in adults at any stage of the disease. We searched CENTRAL, MEDLINE, Embase and LILACS up to August 2017. We included randomised or quasi-randomised controlled trials that assessed adults with trigger finger and compared any type of surgical treatment with each other or with any other non-surgical intervention. The major outcomes were the resolution of trigger finger, pain, hand function, participant-reported treatment success or satisfaction, recurrence of triggering, adverse events and neurovascular injury. Two review authors independently selected the trial reports, extracted the data and assessed the risk of bias. Measures of treatment effect for dichotomous outcomes calculated risk ratios (RRs), and mean differences (MDs) or standardised mean differences (SMD) for continuous outcomes, with 95% confidence intervals (CIs). When possible, the data were pooled into meta-analysis using the random-effects model. GRADE was used to assess the quality of evidence for each outcome. Fourteen trials were included, totalling 1260 participants, with 1361 trigger fingers. The age of participants included in the studies ranged from 16 to 88 years; and the majority of participants were women (approximately 70%). The average duration of symptoms ranged from three to 15 months, and the follow-up after the procedure ranged from eight weeks to 23 months.The studies reported nine types of comparisons: open surgery versus steroid injections (two

  11. Upper Limb Muscle and Brain Activity in Light Assembly Task on Different Load Levels

    Science.gov (United States)

    Zadry, Hilma Raimona; Dawal, Siti Zawiah Md.; Taha, Zahari

    2010-10-01

    A study was conducted to investigate the effect of load on upper limb muscles and brain activities in light assembly task. The task was conducted at two levels of load (Low and high). Surface electromyography (EMG) was used to measure upper limb muscle activities of twenty subjects. Electroencephalography (EEG) was simultaneously recorded with EMG to record brain activities from Fz, Pz, O1 and O2 channels. The EMG Mean Power Frequency (MPF) of the right brachioradialis and the left upper trapezius activities were higher on the high-load task compared to low-load task. The EMG MPF values also decrease as time increases, that reflects muscle fatigue. Mean power of the EEG alpha bands for the Fz-Pz channels were found to be higher on the high-load task compared to low-load task, while for the O1-O2 channels, they were higher on the low-load task than on the high-load task. These results indicated that the load levels effect the upper limb muscle and brain activities. The high-load task will increase muscle activities on the right brachioradialis and the left upper tapezius muscles, and will increase the awareness and motivation of the subjects. Whilst the low-load task can generate drowsiness earlier. It signified that the longer the time and the more heavy of the task, the subjects will be more fatigue physically and mentally.

  12. Triggering at high luminosity: fake triggers from pile-up

    International Nuclear Information System (INIS)

    Johnson, R.

    1983-01-01

    Triggers based on a cut in transverse momentum (p/sub t/) have proved to be useful in high energy physics both because they indicte that a hard constituent scattering has occurred and because they can be made quickly enough to gate electronics. These triggers will continue to be useful at high luminosities if overlapping events do not cause an excessive number of fake triggers. In this paper, I determine if this is indeed a problem at high luminosity machines

  13. Nostalgia: content, triggers, functions.

    Science.gov (United States)

    Wildschut, Tim; Sedikides, Constantine; Arndt, Jamie; Routledge, Clay

    2006-11-01

    Seven methodologically diverse studies addressed 3 fundamental questions about nostalgia. Studies 1 and 2 examined the content of nostalgic experiences. Descriptions of nostalgic experiences typically featured the self as a protagonist in interactions with close others (e.g., friends) or in momentous events (e.g., weddings). Also, the descriptions contained more expressions of positive than negative affect and often depicted the redemption of negative life scenes by subsequent triumphs. Studies 3 and 4 examined triggers of nostalgia and revealed that nostalgia occurs in response to negative mood and the discrete affective state of loneliness. Studies 5, 6, and 7 investigated the functional utility of nostalgia and established that nostalgia bolsters social bonds, increases positive self-regard, and generates positive affect. These findings demarcate key landmarks in the hitherto uncharted research domain of nostalgia.

  14. The ATLAS hadronic tau trigger

    CERN Document Server

    Black, C; The ATLAS collaboration

    2012-01-01

    With the high luminosities of proton-proton collisions achieved at the LHC, the strategies for triggering have become more important than ever for physics analysis. The naive inclusive single tau lepton triggers now suffer from severe rate limitations. To allow for a large program of physics analyses with taus, the development of topological triggers that combine tau signatures with other measured quantities in the event is required. These combined triggers open many opportunities to study new physics beyond the Standard Model and to search for the Standard Model Higgs. We present the status and performance of the hadronic tau trigger in ATLAS. We demonstrate that the ATLAS tau trigger ran remarkably well over 2011, and how the lessons learned from 2011 led to numerous improvements in the preparation of the 2012 run. These improvements include the introduction of tau selection criteria that are robust against varying pileup scenarios, and the implementation of multivariate selection techniques in the tau trig...

  15. The ATLAS hadronic tau trigger

    CERN Document Server

    Black, C; The ATLAS collaboration

    2012-01-01

    With the high luminosities of proton-proton collisions achieved at the LHC, the strategies for triggering have become more important than ever for physics analysis. The naïve inclusive single tau lepton triggers now suffer from severe rate limitations. To allow for a large program of physics analyses with taus, the development of topological triggers that combine tau signatures with other measured quantities in the event is required. These combined triggers open many opportunities to study new physics beyond the Standard Model and to search for the Standard Model Higgs. We present the status and performance of the hadronic tau trigger in ATLAS. We demonstrate that the ATLAS tau trigger ran remarkably well over 2011, and how the lessons learned from 2011 led to numerous improvements in the preparation of the 2012 run. These improvements include the introduction of tau selection criteria that are robust against varying pileup scenarios, and the implementation of multivariate selection techniques in the tau tri...

  16. The ATLAS hadronic tau trigger

    International Nuclear Information System (INIS)

    Shamim, Mansoora

    2012-01-01

    The extensive tau physics programs of the ATLAS experiment relies heavily on trigger to select hadronic decays of tau lepton. Such a trigger is implemented in ATLAS to efficiently collect signal events, while keeping the rate of multi-jet background within the allowed bandwidth. This contribution summarizes the performance of the ATLAS hadronic tau trigger system during 2011 data taking period and improvements implemented for the 2012 data collection.

  17. Flexible trigger menu implementation on the Global Trigger for the CMS Level-1 trigger upgrade

    Science.gov (United States)

    MATSUSHITA, Takashi; CMS Collaboration

    2017-10-01

    The CMS experiment at the Large Hadron Collider (LHC) has continued to explore physics at the high-energy frontier in 2016. The integrated luminosity delivered by the LHC in 2016 was 41 fb-1 with a peak luminosity of 1.5 × 1034 cm-2s-1 and peak mean pile-up of about 50, all exceeding the initial estimations for 2016. The CMS experiment has upgraded its hardware-based Level-1 trigger system to maintain its performance for new physics searches and precision measurements at high luminosities. The Global Trigger is the final step of the CMS Level-1 trigger and implements a trigger menu, a set of selection requirements applied to the final list of objects from calorimeter and muon triggers, for reducing the 40 MHz collision rate to 100 kHz. The Global Trigger has been upgraded with state-of-the-art FPGA processors on Advanced Mezzanine Cards with optical links running at 10 GHz in a MicroTCA crate. The powerful processing resources of the upgraded system enable implementation of more algorithms at a time than previously possible, allowing CMS to be more flexible in how it handles the available trigger bandwidth. Algorithms for a trigger menu, including topological requirements on multi-objects, can be realised in the Global Trigger using the newly developed trigger menu specification grammar. Analysis-like trigger algorithms can be represented in an intuitive manner and the algorithms are translated to corresponding VHDL code blocks to build a firmware. The grammar can be extended in future as the needs arise. The experience of implementing trigger menus on the upgraded Global Trigger system will be presented.

  18. Analgesic efficacy of ultrasound identified trigger point injection in myofascial pain syndrome: A pilot study in Indian patients

    Directory of Open Access Journals (Sweden)

    S Parthasarathy

    2016-01-01

    Full Text Available Background: Myofascial pain syndrome (MPS is described as sensory symptoms, sometimes with motor and autonomic symptoms caused by myofascial trigger points (TPs. Injection at TPs is most likely to benefit patients with such disorder. The identification of TPs is usually clinical. However, in sites where there are major vital structures, ultrasound guidance and real-time visualization may help in decreasing complications. Methodology: Twenty patients who presented to pain clinic with classic symptoms of MPS in the neck and shoulder area with clinically detectable TPs were selected. The points were imaged with ultrasound to find correlation with clinical positions. They were injected with a mixture of local anesthetic and steroid on TPs with real-time ultrasound guidance and needle visualization. Pretreatment visual analog scale (VAS scores and posttreatment (immediate and after 1 month were noted. The mean reduction in VAS scores was analyzed with paired Student′s t-test. Any side effect was observed and managed. Results: Clinically detectable TPs coincided with an echogenic point on the undersurface of the trapezius. There was a significant reduction in pain scores at both times. The needle sign was positive in all the cases. There were no major complications. Conclusion: The clinically identified TPs in trapezius muscle coincided well with ultrasound imaged echogenic structure in the muscle in all the cases. Ultrasound-assisted injections also produced the needle sign in all the cases. The achieved analgesia both immediately after the injection and a month later was satisfactory in the majority of cases. The echogenic mass corresponding to the TP is found to be on the undersurface of the muscle rather than inside the mass of the muscle.

  19. Trigger and data acquisition

    CERN Multimedia

    CERN. Geneva; Gaspar, C

    2001-01-01

    Past LEP experiments generate data at 0.5 MByte/s from particle detectors with over a quarter of a million readout channels. The process of reading out the electronic channels, treating them, and storing the date produced by each collision for further analysis by the physicists is called "Data Acquisition". Not all beam crossings produce interesting physics "events", picking the interesting ones is the task of the "Trigger" system. In order to make sure that the data is collected in good conditions the experiment's operation has to be constantly verified. In all, at LEP experiments over 100 000 parameters were monitored, controlled, and synchronized by the "Monotoring and control" system. In the future, LHC experiments will produce as much data in a single day as a LEP detector did in a full year's running with a raw data rate of 10 - 100 MBytes/s and will have to cope with some 800 million proton-proton collisions a second of these collisions only one in 100 million million is interesting for new particle se...

  20. The TOTEM modular trigger system

    Energy Technology Data Exchange (ETDEWEB)

    Bagliesi, M.G., E-mail: mg.bagliesi@pi.infn.i [University of Siena and INFN Pisa (Italy); Berretti, M.; Cecchi, R.; Greco, V.; Lami, S.; Latino, G.; Oliveri, E.; Pedreschi, E.; Scribano, A.; Spinella, F.; Turini, N. [University of Siena and INFN Pisa (Italy)

    2010-05-21

    The TOTEM experiment will measure the total cross-section with the luminosity independent method and study elastic and diffractive scattering at the LHC. We are developing a modular trigger system, based on programmable logic, that will select meaningful events within 2.5{mu}s. The trigger algorithm is based on a tree structure in order to obtain information compression. The trigger primitive is generated directly on the readout chip, VFAT, that has a specific fast output that gives low resolution hits information. In two of the TOTEM detectors, Roman Pots and T2, a coincidence chip will perform track recognition directly on the detector readout boards, while for T1 the hits are transferred from the VFATs to the trigger hardware. Starting from more than 2000 bits delivered by the detector electronics, we extract, in a first step, six trigger patterns of 32 LVDS signals each; we build, then, on a dedicated board, a 1-bit (L1) trigger signal for the TOTEM experiment and 16 trigger bits to the CMS experiment global trigger system for future common data taking.

  1. The TOTEM modular trigger system

    International Nuclear Information System (INIS)

    Bagliesi, M.G.; Berretti, M.; Cecchi, R.; Greco, V.; Lami, S.; Latino, G.; Oliveri, E.; Pedreschi, E.; Scribano, A.; Spinella, F.; Turini, N.

    2010-01-01

    The TOTEM experiment will measure the total cross-section with the luminosity independent method and study elastic and diffractive scattering at the LHC. We are developing a modular trigger system, based on programmable logic, that will select meaningful events within 2.5μs. The trigger algorithm is based on a tree structure in order to obtain information compression. The trigger primitive is generated directly on the readout chip, VFAT, that has a specific fast output that gives low resolution hits information. In two of the TOTEM detectors, Roman Pots and T2, a coincidence chip will perform track recognition directly on the detector readout boards, while for T1 the hits are transferred from the VFATs to the trigger hardware. Starting from more than 2000 bits delivered by the detector electronics, we extract, in a first step, six trigger patterns of 32 LVDS signals each; we build, then, on a dedicated board, a 1-bit (L1) trigger signal for the TOTEM experiment and 16 trigger bits to the CMS experiment global trigger system for future common data taking.

  2. Upgrade trigger: Biannual performance update

    CERN Document Server

    Aaij, Roel; Couturier, Ben; Esen, Sevda; De Cian, Michel; De Vries, Jacco Andreas; Dziurda, Agnieszka; Fitzpatrick, Conor; Fontana, Marianna; Grillo, Lucia; Hasse, Christoph; Jones, Christopher Rob; Le Gac, Renaud; Matev, Rosen; Neufeld, Niko; Nikodem, Thomas; Polci, Francesco; Del Buono, Luigi; Quagliani, Renato; Schwemmer, Rainer; Seyfert, Paul; Stahl, Sascha; Szumlak, Tomasz; Vesterinen, Mika Anton; Wanczyk, Joanna; Williams, Mark Richard James; Yin, Hang; Zacharjasz, Emilia Anna

    2017-01-01

    This document presents the performance of the LHCb Upgrade trigger reconstruction sequence, incorporating changes to the underlying reconstruction algorithms and detector description since the Trigger and Online Upgrade TDR. An updated extrapolation is presented using the most recent example of an Event Filter Farm node.

  3. Minimum Bias Trigger in ATLAS

    International Nuclear Information System (INIS)

    Kwee, Regina

    2010-01-01

    Since the restart of the LHC in November 2009, ATLAS has collected inelastic pp collisions to perform first measurements on charged particle densities. These measurements will help to constrain various models describing phenomenologically soft parton interactions. Understanding the trigger efficiencies for different event types are therefore crucial to minimize any possible bias in the event selection. ATLAS uses two main minimum bias triggers, featuring complementary detector components and trigger levels. While a hardware based first trigger level situated in the forward regions with 2.2 < |η| < 3.8 has been proven to select pp-collisions very efficiently, the Inner Detector based minimum bias trigger uses a random seed on filled bunches and central tracking detectors for the event selection. Both triggers were essential for the analysis of kinematic spectra of charged particles. Their performance and trigger efficiency measurements as well as studies on possible bias sources will be presented. We also highlight the advantage of these triggers for particle correlation analyses. (author)

  4. Development of a clinical prediction rule for identifying women with tension-type headache who are likely to achieve short-term success with joint mobilization and muscle trigger point therapy.

    Science.gov (United States)

    Fernández-de-las-Peñas, César; Cleland, Joshua A; Palomeque-del-Cerro, Luis; Caminero, Ana Belén; Guillem-Mesado, Amparo; Jiménez-García, Rodrigo

    2011-02-01

    To identify prognostic factors from the history and physical examination in women with tension-type headache (TTH) who are likely to experience self-perceived clinical improvement following a multimodal physical therapy session including joint mobilization and muscle trigger point (TrP) therapies. No definitive therapeutic intervention is available for TTH. It would be useful for clinicians to have a clinical prediction rule for selecting which TTH patients may experience improved outcomes following a multimodal physical therapy program. Women diagnosed with pure TTH by 3 experienced neurologists according to the International Headache Society criteria from different neurology departments were included. They underwent a standardized examination (neck mobility, pressure pain thresholds, total tenderness score, presence of muscle TrPs, Medical Outcomes Study 36-Item Short Form, the Neck Disability Index [NDI], the Beck Depression Inventory, and the Headache Disability Inventory) and then a multimodal physical therapy session including joint mobilization and TrP therapies. The treatment session included a 30-second grade III or IV central posterior-anterior nonthrust mobilization applied from T4 to T1 thoracic vertebrae, at C7-T1 cervico-thoracic junction and C1-C2 vertebrae for an overall intervention time of 5 minutes Different TrP techniques, particularly soft tissue stroke, pressure release, or muscle energy were applied to head and neck-shoulder muscles (temporalis, suboccipital, upper trapezius, splenius capitis, semispinalis capitis, sternocleidomastoid) to inactivate active muscle TrPs. Participants were classified as having achieved a successful outcome 1 week after the session based on their self-perceived recovery. Potential prognostic variables were entered into a stepwise logistic regression model to determine the most accurate set of variables for prediction of success. Data for 76 subjects were included in the analysis, of which 36 experienced a

  5. [EFFECTIVENESS OF CLAVICULAR HOOK PLATE COMBINED WITH TRAPEZIUS MUSCLE FASCIA FOR RECONSTRUCTION OF ACROMIOCLAVICULAR AND CORACOCLAVICULAR LIGAMENTS TO TREAT COMPLETE ACROMIOCLAVICULAR JOINT DISLOCATION].

    Science.gov (United States)

    Wang, Chaoliang; Wang, Yingzhen; Zhu, Tao; Sun, Xuesheng; Lin, Chu; Gao, Bo; Li, Xinxia

    2015-02-01

    To explore the effectiveness of the clavicular hook plate combined with trapezius muscle fascia for reconstruction of acromioclavicular and coracoclavicular ligaments to treat acute complete acromioclavicular dislocations. Between January 2008 and April 2012, 66 patients with acromioclavicular dislocation were treated with the clavicular hook plate combined with trapezius muscle fascia for reconstruction of acromioclavicular and coracoclavicular ligaments in 32 cases (experimental group) and with the clavicular hook plate in 34 cases (control group). There was no significant difference in gender, age, injured side, the cause of injury, and the time from injury to operation between 2 groups (P > 0.05). Visual analogue scale (VAS), Constant shoulder scores, and coracoid clavi-cledistance (CC. Dist) were measured at preoperation and at 2 years after operation. Signal/noise quotiem (SNQ) was measured by MRI at 2 years after operation. The operation complications were observed. The patients of 2 groups obtained primary healing of incision. The morbidity of complication in experimental group (12.5%, 4/32) was significantly lower than that in control group (91.2%, 31/34) (Χ2 = 40.96, P = 0.00). All the cases were followed up 2.8 years on average (range, 2 to 4 years). VAS scores and CC.Dist significantly decreased at 2 years after operation when compared with preoperative values in the 2 groups (P acromioclavicular and coracoclavicular ligaments is successful in treating acute complete acromioclavicular dislocations, with the advantages of higher ligament healing, less complication, and early improvement of shoulder functions.

  6. DUMAND data acquisition with triggering

    International Nuclear Information System (INIS)

    Brenner, A.E.; Theriot, D.; March, R.H.

    1980-01-01

    A data acquisition scheme for the standard DUMAND array that includes a simple triggering scheme as a fundamental part of the system is presented. Although there are a number of not yet fully understood parameters, it is assumed that thresholds can be set in such a manner as to give rise to a triggered signal that is not so dominated by randoms that it gives a substantial decrease in the data acquisition rate over that which would be required by a nontriggered system. It is also assumed that the triggering logic is relatively simple and does not need major computational capabilities for a trigger logic decision. With these assumptions, it is possible to generate the trigger at the array and restrict the data transfer to shore. However, with a not unreasonable delay of 200 microseconds, it is even possible to transmit the information for the trigger to shore and perform all that logic on the shore. The critical point is to send the minimum amount of information necessary to construct the trigger such that one need not send all the possible information in all detectors of the array continuously to shore. 1 figure

  7. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  8. The CDF level-3 trigger

    International Nuclear Information System (INIS)

    Devlin, T.

    1993-01-01

    The Collider Detector at Fermilab (CDF) has been operating at the Tevatron and collecting data on proton-antiproton interactions with collision rates above 250,000 Hz. Three levels of filtering select events for data logging at a rate of about 4 Hz. The Level 3 trigger provides most of the capabilities of the offline production programs for event reconstruction and physics analysis. The type of physics triggers, application of cuts, and combinations of logical requirements for event selection are controlled at run time by a trigger table using a syntax fully integrated with the Level 1 and Level 2 hardware triggers. The level 3 software operates in 48 RISC/UNIX processors (over 1000 mips) served by four 20-MByte/sec data buses for input, output and control. The system architecture, debugging, code validation, error reporting, analysis capabilities and performance will be described

  9. Upper Gastrointestinal (GI) Series

    Science.gov (United States)

    ... standard barium upper GI series, which uses only barium a double-contrast upper GI series, which uses both air and ... evenly coat your upper GI tract with the barium. If you are having a double-contrast study, you will swallow gas-forming crystals that ...

  10. Bilateral responses of upper limb muscles to transcranial magnetic stimulation in human subjects.

    Science.gov (United States)

    Bawa, P; Hamm, J D; Dhillon, P; Gross, P A

    2004-10-01

    Anatomical and behavioural work on primates has shown bilateral innervation of axial and proximal limb muscles, and contralateral control of distal limb muscles. The following study examined if a clear boundary exists between the distal and proximal upper limb muscles that are controlled contralaterally or bilaterally. The right motor cortical area representing the upper limb was stimulated, while surface EMG was recorded bilaterally from various upper limb muscles during rest and phasic voluntary contractions. Peak-to-peak amplitude of motor evoked potential (MEP) was measured for each muscle on both sides. The ratio R = (ipsilateral MEP: contralateral MEP) was calculated for seven pairs of muscles. For each of the seven pairs, R was less than 1.0, implying that for each muscle and subject, the contralateral control is stronger. The boundary where R changed from almost zero to a clearly measurable magnitude depended on the subject. Ipsilateral MEPs from trapezius and pectoralis could be recorded with a small background contraction from almost all subjects; on the other hand, in deltoid and biceps brachii, ipsilateral MEPs were observed only with bimanual phasic contractions. The forearm and hand muscles, in general, did not show any ipsilateral MEPs. Major differences between subjects lay in the presence or the absence of ipsilateral MEPs in biceps brachii and deltoid, without defining a sharp boundary between proximal and distal muscles.

  11. Clinical signs and physical function in neck and upper extremities among elderly female computer users: the NEW study

    DEFF Research Database (Denmark)

    Juul-Kristensen, B; Kadefors, R; Hansen, K

    2006-01-01

    -reported neck/shoulder trouble have more clinical findings than those not reporting trouble, and that a corresponding pattern holds true for physical function. In total 42 and 61 questionnaire-defined NS cases and NS controls participated and went through a clinical examination of the neck and upper extremities...... and five physical function tests: maximal voluntary contraction (MVC) of shoulder elevation, abduction, and handgrip, as well as endurance at 30% MVC shoulder elevation and a physical performance test. Based on clinical signs and symptoms, trapezius myalgia (38%), tension neck syndrome (17......%) and cervicalgia (17%) were the most frequent diagnoses among NS cases, and were significantly more frequent among NS cases than NS controls. A total of 60% of the subjects with reported trouble had one or several of the diagnoses located in the neck/shoulder. Physical function of the shoulder was lower...

  12. Flexible trigger menu implementation on the Global Trigger for the CMS Level-1 trigger upgrade

    CERN Document Server

    Matsushita, Takashi

    2017-01-01

    The CMS experiment at the Large Hadron Collider (LHC) has continued to explore physics at the high-energy frontier in 2016. The integrated luminosity delivered by the LHC in 2016 was 41~fb$^{-1}$ with a peak luminosity of 1.5 $\\times$ 10$^{34}$ cm$^{-2}$s$^{-1}$ and peak mean pile-up of about 50, all exceeding the initial estimations for 2016. The CMS experiment has upgraded its hardware-based Level-1 trigger system to maintain its performance for new physics searches and precision measurements at high luminosities. The Global Trigger is the final step of the CMS \\mbox{Level-1} trigger and implements a trigger menu, a set of selection requirements applied to the final list of objects from calorimeter and muon triggers, for reducing the 40 MHz collision rate to 100 kHz. The Global Trigger has been upgraded with state-of-the-art FPGA processors on Advanced Mezzanine Cards with optical links running at 10 GHz in a MicroTCA crate. The powerful processing resources of the upgraded system enable implemen...

  13. Trigger processing using reconfigurable logic in the CMS calorimeter trigger

    Energy Technology Data Exchange (ETDEWEB)

    Brooke, J J; Cussans, D G; Heath, G P; Maddox, A J; Newbold, D M; Rabbetts, P D

    2001-04-01

    We present the design of the Global Calorimeter Trigger processor for the CMS detector at LHC. This is a fully pipelined processor system which collects data from all the CMS calorimeters and produces summary information used in forming the Level-1 trigger decision for each event. The design in based on the use of state-of-the-art reconfigurable logic devices (FPGAs) and fast data links. We present the results of device testing using a low-latency pipelined sort algorithm, which demonstrate that an FPGA can be used to perform processing previously foreseen to require custom ASICs. Our design approach results in a powerful, flexible and compact processor system.

  14. The DOe Silicon Track Trigger

    International Nuclear Information System (INIS)

    Steinbrueck, Georg

    2003-01-01

    We describe a trigger preprocessor to be used by the DOe experiment for selecting events with tracks from the decay of long-lived particles. This Level 2 impact parameter trigger utilizes information from the Silicon Microstrip Tracker to reconstruct tracks with improved spatial and momentum resolutions compared to those obtained by the Level 1 tracking trigger. It is constructed of VME boards with much of the logic existing in programmable processors. A common motherboard provides the I/O infrastructure and three different daughter boards perform the tasks of identifying the roads from the tracking trigger data, finding the clusters in the roads in the silicon detector, and fitting tracks to the clusters. This approach provides flexibility for the design, testing and maintenance phases of the project. The track parameters are provided to the trigger framework in 25 μs. The effective impact parameter resolution for high-momentum tracks is 35 μm, dominated by the size of the Tevatron beam

  15. Review Document: Full Software Trigger

    CERN Document Server

    Albrecht, J; Raven, G

    2014-01-01

    This document presents a trigger system for the upgraded LHCb detector, scheduled to begin operation in 2020. This document serves as input for the internal review towards the "DAQ, online and trigger TDR". The proposed trigger system is implemented entirely in software. In this document we show that track reconstruction of a similar quality to that available in the offline algorithms can be performed on the full inelastic $pp$-collision rate, without prior event selections implemented in custom hardware and without relying upon a partial event reconstruction. A track nding eciency of 98.8 % relative to oine can be achieved for tracks with $p_T >$ 500 MeV/$c$. The CPU time required for this reconstruction is about 40 % of the available budget. Proof-of-principle selections are presented which demonstrate that excellent performance is achievable using an inclusive beauty trigger, in addition to exclusive beauty and charm triggers. Finally, it is shown that exclusive beauty and charm selections that do not intr...

  16. Genetic parameters for image analysis traits on M. longissimus thoracis and M. trapezius of carcass cross section in Japanese Black steers.

    Science.gov (United States)

    Osawa, T; Kuchida, K; Hidaka, S; Kato, T

    2008-01-01

    In Japan, the degree of marbling in ribeye (M. longissimus thoracis) is evaluated in the beef meat grading process. However, other muscles (e.g., M. trapezius) are also important in determining the meat quality and carcass market prices. The purpose of this study was to estimate genetic parameters for M. longissimus thoracis (M-LONG) and M. trapezius (M-TRAP) of carcass cross section of Japanese Black steers by computer image analysis. The number of records of Japanese Black steers and the number of pedigree records were 2,925 and 10,889, respectively. Digital images of the carcass cross section were taken between the sixth and seventh ribs by photographing equipment. Muscle area (MA), fat area ratio (FAR), overall coarseness of marbling particles (OCM), and coarseness of maximum marbling particle (MMC) in M-LONG and M-TRAP were calculated by image analysis. Genetic parameters for these traits were estimated using the AIREMLF90 program with an animal model. Fixed effects that were included in the model were dates of arrival at the carcass market and slaughter age (mo), and random effects of fattening farms, additive genetic effects and residuals were included in the model. For M-LONG, heritability estimates (+/-SE) were 0.46 +/- 0.06, 0.59 +/- 0.06, 0.47 +/- 0.06, and 0.20 +/- 0.05 for MA, FAR, OCM, and MMC, respectively. Heritability estimates (+/-SE) in M-TRAP were 0.47 +/- 0.06, 0.57 +/- 0.07, 0.49 +/- 0.07, and 0.13 +/- 0.04 for the same traits. Genetic correlations between subcutaneous fat thickness and FAR for M-LONG and M-TRAP were negative (-0.21 and -0.19, respectively). Those correlations between M-LONG and M-TRAP were moderate to high for MA, FAR, OCM, and MMC (0.38, 0.52, 0.39, and 0.60, respectively). These results indicate that other muscles including M-LONG should be evaluated for more efficient genetic improvement.

  17. ATLAS FTK Fast Track Trigger

    CERN Document Server

    Iizawa, T; The ATLAS collaboration

    2014-01-01

    The Fast TracKer (FTK) will perform global track reconstruction after each Level-1 trigger accept signal to enable the software-based higher level trigger to have early access to tracking information. FTK is a dedicated processor based on a mixture of advanced technologies. Modern, powerful Field Programmable Gate Arrays (FPGAs) form an important part of the system architecture, and the large level of computing power required for pattern recognition is provided by incorporating standard-cell ASICs named Associative Memory (AM). Motivation and the architecture of the FTK system will be presented, and the status of hardware and simulation will be following.

  18. RPC Trigger Robustness: Status Report

    CERN Document Server

    Di Mattia, A; Nisati, A; Pastore, F; Vari, R; Veneziano, Stefano; Aielli, G; Camarri, P; Cardarelli, R; Di Ciaccio, A; Di Simone, A; Liberti, B; Santonico, R

    2002-01-01

    The present paper describes the Level-1 Barrel Muon Trigger performance as expected with the current configuration of the RPC detectors designed for the Barrel Muon Spectrometer of ATLAS. Results of a beam test performed at the X5-GIF facility at CERN are presented in order to show the trigger efficiency with different conditions of RPC detection efficiency and several background rates. Small (50$\\times$50 cm$^2$) RPC chambers with final Front-end electronics and splitter boards are used in the test, while the coincidence logic is applied off-line using a detailed simulation of the coincidence matrix.

  19. Fast processor for dilepton triggers

    International Nuclear Information System (INIS)

    Katsanevas, S.; Kostarakis, P.; Baltrusaitis, R.

    1983-01-01

    We describe a fast trigger processor, developed for and used in Fermilab experiment E-537, for selecting high-mass dimuon events produced by negative pions and anti-protons. The processor finds candidate tracks by matching hit information received from drift chambers and scintillation counters, and determines their momenta. Invariant masses are calculated for all possible pairs of tracks and an event is accepted if any invariant mass is greater than some preselectable minimum mass. The whole process, accomplished within 5 to 10 microseconds, achieves up to a ten-fold reduction in trigger rate

  20. Landslides triggered by the storm of November 3-5, 1985, Wills Mountain Anticline, West Virginia and Virginia: Chapter C in Geomorphic studies of the storm and flood of November 3-5, 1985, in the upper Potomac and Cheat River basins in West Virginia and Virginia

    Science.gov (United States)

    Jacobson, Robert B.; McGeehin, John P.; Cron, Elizabeth D.; Carr, Carolyn E.; Harper, John M.; Howard, Alan D.

    1993-01-01

    More than 3,000 landslides were triggered by heavy rainfall in the central Appalachian Mountains of West Virginia and Virginia, November 3-5, 1985. These landslides provided the opportunity to study spatial controls on landslides, magnitude and frequency of triggering events, and the effects of landslides on flood-induced geomorphic change. The study area consists of parts of the Wills Mountain anticline, a major NE-trending structure in the central Appalachians, and a portion of the adjacent Appalachian Plateau. Across the anticline and adjacent plateau, bedrock lithologies vary markedly and include pure marine limestone, marine shale, deltaic mudstone/sandstone sequences, and orthoquartzites. Because of the geologic structure, bedrock lithology varies little along strike. The spatial distribution of landslides triggered by the storm was controlled primarily by rainfall, bedrock lithology, surficial lithology, land cover, and slope morphology. The triggering rainfall was of moderate intensity and long duration. Two-day storm totals varied from 170 mm to more than 240 mm in the study area. Most landslides occurred at the northeast end of the study area, where 48-h rainfall totals were in excess of 200 mm. Different rainfall thresholds are apparent for triggering landslides on different bedrock lithologies. The highest density of landslides occurred in shallow colluvium and residuum of the Reedsville Shale (Ordovician), followed by regolith of the Greenbriar and Mauch Chunk Groups (Mississippian). Most of the landslides in these fine-grained regoliths were shallow slides and slumps, many of which transformed to mudflows and delivered sediment directly to streams; a smaller number of debris avalanches were triggered high on quartzite ridges.Instability of colluvium and residuum derived from the Reedsville Shale, compared with regolith from four other fine-grained bedrock lithologies, is attributable to its low strength combined with moderate infiltration rates that

  1. DT Local Trigger performance in 2015

    CERN Document Server

    CMS Collaboration

    2015-01-01

    The Local Trigger system of the CMS Drift Tube chambers (DT) was checked applying similar methods as in the LHC Run 1 (2012). The main variables shown in this note are the trigger efficiency, the trigger quality and the fraction of trigger ghosts. The performance was found to be comparable or better than in Run 1.

  2. The Trigger for Early Running

    CERN Document Server

    The ATLAS Collaboration

    2009-01-01

    The ATLAS trigger and data acquisition system is based on three levels of event selection designed to capture the physics of interest with high efficiency from an initial bunch crossing rate of 40 MHz. The selections in the three trigger levels must provide sufficient rejection to reduce the rate to 200 Hz, compatible with offline computing power and storage capacity. The LHC is expected to begin its operation with a peak luminosity of 10^31 with a relatively small number of bunches, but quickly ramp up to higher luminosities by increasing the number of bunches, and thus the overall interaction rate. Decisions must be taken every 25 ns during normal LHC operations at the design luminosity of 10^34, where the average bunch crossing will contain more than 20 interactions. Hence, trigger selections must be deployed that can adapt to the changing beam conditions while preserving the interesting physics and satisfying varying detector requirements. In this paper, we provide a menu of trigger selections that can be...

  3. The CDF Silicon Vertex Trigger

    International Nuclear Information System (INIS)

    Dell'Orso, Mauro

    2006-01-01

    Motivations, design, performance and ongoing upgrade of the CDF Silicon Vertex Trigger are presented. The system provides CDF with a powerful tool for online tracking with offline quality in order to enhance the reach on B-physics and large P t -physics coupled to b quarks

  4. Preliminary observations on high energy phosphates and metabolic pathway and transporter potentials in extensor carpi radialis brevis and trapezius muscles of women with work-related myalgia.

    Science.gov (United States)

    Green, Howard J; Ranney, Don; Burnett, Margaret; Galvin, Patti; Kyle, Natasha; Lounsbury, David; Ouyang, Jing; Smith, Ian C; Stewart, Riley; Tick, Heather; Tupling, A Russell

    2014-11-01

    This study compared both the extensor carpi radialis brevis (ECRB) and the trapezius (TRAP) muscles of women with work-related myalgia (WRM) with healthy controls (CON) to determine whether abnormalities existed in cellular energy status and the potentials of the various metabolic pathways and segments involved in energy production and substrate transport. For both the ECRB (CON, n = 6-9; WRM, n = 13) and the TRAP (CON, n = 6-7; WRM, n = 10), no differences (P > 0.05) were found for the concentrations (in millimoles per kilogram of dry mass) of ATP, PCr, lactate, and glycogen. Similarly, with one exception, the maximal activities (in moles per milligram of protein per hour) of mitochondrial enzymes representative of the citric acid cycle (CAC), the electron transport chain (ETC), and β-oxidation, as well as the cytosolic enzymes involved in high energy phosphate transfer, glycogenolysis, glycolysis, lactate oxidation, and glucose phosphorylation were not different (P > 0.05). The glucose transporters GLUT1 and GLUT4, and the monocarboxylate transporters MCT1 and MCT4, were also normal in WRM. It is concluded that, in general, abnormalities in the resting energy and substrate state, the potential of the different metabolic pathways and segments, as well as the glucose and monocarboxylate transporters do not appear to be involved in the cellular pathophysiology of WRM.

  5. Nonvariceal upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang; Golzarian, Jafar

    2007-01-01

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  6. Nonvariceal upper gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang [University of Iowa, Department of Radiology, Iowa, IA (United States); Golzarian, Jafar [University of Iowa, Department of Radiology, Iowa, IA (United States); University of Iowa, Department of Radiology, Carver College of Medicine, Iowa, IA (United States)

    2007-07-15

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  7. Triggers in UA2 and UA1

    International Nuclear Information System (INIS)

    Dorenbosch, J.

    1985-01-01

    The UA2 and UA1 trigger systems are described as they will be used after the upgrade of the CERN SPPS. The luminosity of the collider will increase to 3x10 30 . The bunch spacing is 4 microseconds, comparable to the time available for a second level trigger at the SSC. The first level triggers are very powerful and deliver trigger rates of about 100 Hz. The UA1 second level trigger operates on the final digitizings with a combination of special and general purpose processors. At the highest trigger levels a small farm of processors performs the final reduction. (orig.)

  8. Muon Trigger for Mobile Phones

    Science.gov (United States)

    Borisyak, M.; Usvyatsov, M.; Mulhearn, M.; Shimmin, C.; Ustyuzhanin, A.

    2017-10-01

    The CRAYFIS experiment proposes to use privately owned mobile phones as a ground detector array for Ultra High Energy Cosmic Rays. Upon interacting with Earth’s atmosphere, these events produce extensive particle showers which can be detected by cameras on mobile phones. A typical shower contains minimally-ionizing particles such as muons. As these particles interact with CMOS image sensors, they may leave tracks of faintly-activated pixels that are sometimes hard to distinguish from random detector noise. Triggers that rely on the presence of very bright pixels within an image frame are not efficient in this case. We present a trigger algorithm based on Convolutional Neural Networks which selects images containing such tracks and are evaluated in a lazy manner: the response of each successive layer is computed only if activation of the current layer satisfies a continuation criterion. Usage of neural networks increases the sensitivity considerably comparable with image thresholding, while the lazy evaluation allows for execution of the trigger under the limited computational power of mobile phones.

  9. Stimulus conflict triggers behavioral avoidance.

    Science.gov (United States)

    Dignath, David; Eder, Andreas B

    2015-12-01

    According to a recent extension of the conflict-monitoring theory, conflict between two competing response tendencies is registered as an aversive event and triggers a motivation to avoid the source of conflict. In the present study, we tested this assumption. Over five experiments, we examined whether conflict is associated with an avoidance motivation and whether stimulus conflict or response conflict triggers an avoidance tendency. Participants first performed a color Stroop task. In a subsequent motivation test, participants responded to Stroop stimuli with approach- and avoidance-related lever movements. These results showed that Stroop-conflict stimuli increased the frequency of avoidance responses in a free-choice motivation test, and also increased the speed of avoidance relative to approach responses in a forced-choice test. High and low proportions of response conflict in the Stroop task had no effect on avoidance in the motivation test. Avoidance of conflict was, however, obtained even with new conflict stimuli that had not been presented before in a Stroop task, and when the Stroop task was replaced with an unrelated filler task. Taken together, these results suggest that stimulus conflict is sufficient to trigger avoidance.

  10. Industrial accidents triggered by lightning.

    Science.gov (United States)

    Renni, Elisabetta; Krausmann, Elisabeth; Cozzani, Valerio

    2010-12-15

    Natural disasters can cause major accidents in chemical facilities where they can lead to the release of hazardous materials which in turn can result in fires, explosions or toxic dispersion. Lightning strikes are the most frequent cause of major accidents triggered by natural events. In order to contribute towards the development of a quantitative approach for assessing lightning risk at industrial facilities, lightning-triggered accident case histories were retrieved from the major industrial accident databases and analysed to extract information on types of vulnerable equipment, failure dynamics and damage states, as well as on the final consequences of the event. The most vulnerable category of equipment is storage tanks. Lightning damage is incurred by immediate ignition, electrical and electronic systems failure or structural damage with subsequent release. Toxic releases and tank fires tend to be the most common scenarios associated with lightning strikes. Oil, diesel and gasoline are the substances most frequently released during lightning-triggered Natech accidents. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. The UA1 trigger processor

    International Nuclear Information System (INIS)

    Grayer, G.H.

    1981-01-01

    Experiment UA1 is a large multi-purpose spectrometer at the CERN proton-antiproton collider, scheduled for late 1981. The principal trigger is formed on the basis of the energy deposition in calorimeters. A trigger decision taken in under 2.4 microseconds can avoid dead time losses due to the bunched nature of the beam. To achieve this we have built fast 8-bit charge to digital converters followed by two identical digital processors tailored to the experiment. The outputs of groups of the 2440 photomultipliers in the calorimeters are summed to form a total of 288 input channels to the ADCs. A look-up table in RAM is used to convert the digitised photomultiplier signals to energy in one processor, combinations of input channels, and also counts the number of clusters with electromagnetic or hadronic energy above pre-determined levels. Up to twelve combinations of these conditions, together with external information, may be combined in coincidence or in veto to form the final trigger. Provision has been made for testing using simulated data in an off-line mode, and sampling real data when on-line. (orig.)

  12. ATLAS Level-1 Topological Trigger

    CERN Document Server

    Zheng, Daniel; The ATLAS collaboration

    2018-01-01

    The ATLAS experiment has introduced and recently commissioned a completely new hardware sub-system of its first-level trigger: the topological processor (L1Topo). L1Topo consist of two AdvancedTCA blades mounting state-of-the-art FPGA processors, providing high input bandwidth (up to 4 Gb/s) and low latency data processing (200 ns). L1Topo is able to select collision events by applying kinematic and topological requirements on candidate objects (energy clusters, jets, and muons) measured by calorimeters and muon sub-detectors. Results from data recorded using the L1Topo trigger will be presented. These results demonstrate a significantly improved background event rejection, thus allowing for a rate reduction without efficiency loss. This improvement has been shown for several physics processes leading to low-pT leptons, including H->tau tau and J/Psi->mu mu. In addition to describing the L1Topo trigger system, we will discuss the use of an accurate L1Topo simulation as a powerful tool to validate and optimize...

  13. ATLAS FTK: Fast Track Trigger

    CERN Document Server

    Volpi, Guido; The ATLAS collaboration

    2015-01-01

    An overview of the ATLAS Fast Tracker processor is presented, reporting the design of the system, its expected performance, and the integration status. The next LHC runs, with a significant increase in instantaneous luminosity, will provide a big challenge to the trigger and data acquisition systems of all the experiments. An intensive use of the tracking information at the trigger level will be important to keep high efficiency in interesting events, despite the increase in multiple p-p collisions per bunch crossing (pile-up). In order to increase the use of tracks within the High Level Trigger (HLT), the ATLAS experiment planned the installation of an hardware processor dedicated to tracking: the Fast TracKer (FTK) processor. The FTK is designed to perform full scan track reconstruction at every Level-1 accept. To achieve this goal, the FTK uses a fully parallel architecture, with algorithms designed to exploit the computing power of custom VLSI chips, the Associative Memory, as well as modern FPGAs. The FT...

  14. Headache triggers in the US military.

    Science.gov (United States)

    Theeler, Brett J; Kenney, Kimbra; Prokhorenko, Olga A; Fideli, Ulgen S; Campbell, William; Erickson, Jay C

    2010-05-01

    Headaches can be triggered by a variety of factors. Military service members have a high prevalence of headache but the factors triggering headaches in military troops have not been identified. The objective of this study is to determine headache triggers in soldiers and military beneficiaries seeking specialty care for headaches. A total of 172 consecutive US Army soldiers and military dependents (civilians) evaluated at the headache clinics of 2 US Army Medical Centers completed a standardized questionnaire about their headache triggers. A total of 150 (87%) patients were active-duty military members and 22 (13%) patients were civilians. In total, 77% of subjects had migraine; 89% of patients reported at least one headache trigger with a mean of 8.3 triggers per patient. A wide variety of headache triggers was seen with the most common categories being environmental factors (74%), stress (67%), consumption-related factors (60%), and fatigue-related factors (57%). The types of headache triggers identified in active-duty service members were similar to those seen in civilians. Stress-related triggers were significantly more common in soldiers. There were no significant differences in trigger types between soldiers with and without a history of head trauma. Headaches in military service members are triggered mostly by the same factors as in civilians with stress being the most common trigger. Knowledge of headache triggers may be useful for developing strategies that reduce headache occurrence in the military.

  15. The Jefferson Lab Trigger Supervisor System

    International Nuclear Information System (INIS)

    Ed Jastrzembsi; David Abbott; Graham Heyes; R.W. MacLeod; Carl Timmer; Elliott Wolin

    2000-01-01

    We discuss the design and performance of a Trigger Supervisor System for use in nuclear physics experiments at Jefferson Lab. We also discuss the enhanced features of a new Trigger Supervisor Module now under construction

  16. The Jefferson Lab Trigger Supervisor System

    International Nuclear Information System (INIS)

    Jastrzembski, E.; Abbott, D.J.; Heyes, W.G.; MacLeod, R.W.; Timmer, C.; Wolin, E.

    1999-01-01

    The authors discuss the design and performance of a Trigger Supervisor System for use in nuclear physics experiments at Jefferson Lab. They also discuss the enhanced features of a new Trigger Supervisor Module now under construction

  17. The Trigger System of the CMS Experiment

    OpenAIRE

    Felcini, Marta

    2008-01-01

    We give an overview of the main features of the CMS trigger and data acquisition (DAQ) system. Then, we illustrate the strategies and trigger configurations (trigger tables) developed for the detector calibration and physics program of the CMS experiment, at start-up of LHC operations, as well as their possible evolution with increasing luminosity. Finally, we discuss the expected CPU time performance of the trigger algorithms and the CPU requirements for the event filter farm at start-up.

  18. Triggers for a high sensitivity charm experiment

    International Nuclear Information System (INIS)

    Christian, D.C.

    1994-07-01

    Any future charm experiment clearly should implement an E T trigger and a μ trigger. In order to reach the 10 8 reconstructed charm level for hadronic final states, a high quality vertex trigger will almost certainly also be necessary. The best hope for the development of an offline quality vertex trigger lies in further development of the ideas of data-driven processing pioneered by the Nevis/U. Mass. group

  19. Upper respiratory tract (image)

    Science.gov (United States)

    The major passages and structures of the upper respiratory tract include the nose or nostrils, nasal cavity, mouth, throat (pharynx), and voice box (larynx). The respiratory system is lined with a mucous membrane that ...

  20. ACA Federal Upper Limits

    Data.gov (United States)

    U.S. Department of Health & Human Services — Affordable Care Act Federal Upper Limits (FUL) based on the weighted average of the most recently reported monthly average manufacturer price (AMP) for...

  1. First level trigger of the DIRAC experiment

    International Nuclear Information System (INIS)

    Afanas'ev, L.G.; Karpukhin, V.V.; Kulikov, A.V.; Gallas, M.

    2001-01-01

    The logic of the first level trigger of the DIRAC experiment at CERN is described. A parallel running of different trigger modes with tagging of events and optional independent prescaling is realized. A CAMAC-based trigger system is completely computer controlled

  2. Upper gastrointestinal bleeding.

    Science.gov (United States)

    Feinman, Marcie; Haut, Elliott R

    2014-02-01

    Upper gastrointestinal (GI) bleeding remains a commonly encountered diagnosis for acute care surgeons. Initial stabilization and resuscitation of patients is imperative. Stable patients can have initiation of medical therapy and localization of the bleeding, whereas persistently unstable patients require emergent endoscopic or operative intervention. Minimally invasive techniques have surpassed surgery as the treatment of choice for most upper GI bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. The D OE software trigger

    International Nuclear Information System (INIS)

    Linnemann, J.T.; Michigan State Univ., East Lansing, MI

    1992-10-01

    In the D OE experiment, the software filter operates in a processor farm with each node processing a single event. Processing is data-driven: the filter does local processing to verify the candidates from the hardware trigger. The filter code consists of independent pieces called ''tools''; processing for a given hardware bit is a ''script'' invoking one or more ''tools'' sequentially. An offline simulator drives the same code with the same configuration files, running on real or simulated data. Online tests use farm nodes parasiting on the data stream. We discuss the performance of the system and how we attempt to verify its correctness

  4. Calorimeter triggers for hard collisions

    International Nuclear Information System (INIS)

    Landshoff, P.V.; Polkinghorne, J.C.

    1978-01-01

    We discuss the use of a forward calorimeter to trigger on hard hadron-hadron collisions. We give a derivation in the covariant parton model of the Ochs-Stodolsky scaling law for single-hard-scattering processes, and investigate the conditions when instead a multiple- scattering mechanism might dominate. With a proton beam, this mechanism results in six transverse jets, with a total average multiplicity about twice that seen in ordinary events. We estimate that its cross section is likely to be experimentally accessible at avalues of the beam energy in the region of 100 GeV/c

  5. Upper GI Bleeding in Children

    Science.gov (United States)

    Upper GI Bleeding in Children What is upper GI Bleeding? Irritation and ulcers of the lining of the esophagus, stomach or duodenum can result in upper GI bleeding. When this occurs the child may vomit blood ...

  6. Triggering for charm, beauty, and truth

    International Nuclear Information System (INIS)

    Appel, J.A.

    1982-02-01

    As the search for more and more rare processes accelerates, the need for more and more effective event triggers also accelerates. In the earliest experiments, a simple coincidence often sufficed not only as the event trigger, but as the complete record of an event of interest. In today's experiments, not only has the fast trigger become more sophisticated, but one or more additional level of trigger processing precedes writing event data to magnetic tape for later analysis. Further search experiments will certainly require further expansion in the number of trigger levels required to filter those rare events of particular interest

  7. The Database Driven ATLAS Trigger Configuration System

    CERN Document Server

    Martyniuk, Alex; The ATLAS collaboration

    2015-01-01

    This contribution describes the trigger selection configuration system of the ATLAS low- and high-level trigger (HLT) and the upgrades it received in preparation for LHC Run 2. The ATLAS trigger configuration system is responsible for applying the physics selection parameters for the online data taking at both trigger levels and the proper connection of the trigger lines across those levels. Here the low-level trigger consists of the already existing central trigger (CT) and the new Level-1 Topological trigger (L1Topo), which has been added for Run 2. In detail the tasks of the configuration system during the online data taking are Application of the selection criteria, e.g. energy cuts, minimum multiplicities, trigger object correlation, at the three trigger components L1Topo, CT, and HLT On-the-fly, e.g. rate-dependent, generation and application of prescale factors to the CT and HLT to adjust the trigger rates to the data taking conditions, such as falling luminosity or rate spikes in the detector readout ...

  8. Hadronic Triggers and trigger-object level analysis at ATLAS

    CERN Document Server

    Zaripovas, Donatas Ramilas; The ATLAS collaboration

    2017-01-01

    Hadronic signatures are critical to the high energy physics analysis program, and are broadly used for both Standard Model measurements and searches for new physics. These signatures include generic quark and gluon jets, as well as jets originating from b-quarks or the decay of massive particles (such as electroweak bosons or top quarks). Additionally missing transverse momentum from non-interacting particles provides an interesting probe in the search for new physics beyond the Standard Model. Developing trigger selections that target these events is a huge challenge at the LHC due to the enormous rates associated with these signatures. This challenge is exacerbated by the amount of pile-up activity, which continues to grow. In order to address these challenges, several new techniques have been developed during the past year in order to significantly improve the potential of the 2017 dataset and overcome the limiting factors to more deeply probing for new physics, such as storage and computing requirements f...

  9. Hadronic triggers and trigger object-level analysis at ATLAS

    CERN Document Server

    Zaripovas, Donatas Ramilas; The ATLAS collaboration

    2017-01-01

    Hadronic signatures are critical to the high energy physics analysis program at the Large Hadron Collider (LHC), and are broadly used for both Standard Model measurements and searches for new physics. These signatures include generic quark and gluon jets, as well as jets originating from b-quarks or the decay of massive particles (such as electroweak bosons or top quarks). Additionally missing transverse momentum from non-interacting particles provides an interesting probe in the search for new physics beyond the Standard Model. Developing trigger selections that target these events is a huge challenge at the LHC due to the enormous event rates associated with these signatures. This challenge is exacerbated by the amount of pile-up activity, which continues to grow. In order to address these challenges, several new techniques have been developed during the past year in order to significantly improve the potential of the 2017 dataset and overcome the limiting factors, such as storage and computing requirements...

  10. Right upper quadrant pain

    International Nuclear Information System (INIS)

    Ralls, P.W.; Colletti, P.M.; Boswell, W.D. Jr.; Halls, J.M.

    1984-01-01

    Historically, assessment of acute right upper quadrant abdominal pain has been a considerable clinical challenge. While clinical findings and laboratory data frequently narrow the differential diagnosis, symptom overlap generally precludes definitive diagnosis among the various diseases causing acute right upper quadrant pain. Fortunately, the advent of newer diagnostic imaging modalities has greatly improved the rapidity and reliability of diagnosis in these patients. An additional challenge to the physician, with increased awareness of the importance of cost effectiveness in medicine, is to select appropriate diagnostic schema that rapidly establish accurate diagnoses in the most economical fashion possible. The dual goals of this discussion are to assess not only the accuracy of techniques used to evaluate patients with acute right upper quadrant pain, but also to seek out cost-effective, coordinated imaging techniques to achieve this goal

  11. Wired and Wireless Camera Triggering with Arduino

    Science.gov (United States)

    Kauhanen, H.; Rönnholm, P.

    2017-10-01

    Synchronous triggering is an important task that allows simultaneous data capture from multiple cameras. Accurate synchronization enables 3D measurements of moving objects or from a moving platform. In this paper, we describe one wired and four wireless variations of Arduino-based low-cost remote trigger systems designed to provide a synchronous trigger signal for industrial cameras. Our wireless systems utilize 315 MHz or 434 MHz frequencies with noise filtering capacitors. In order to validate the synchronization accuracy, we developed a prototype of a rotating trigger detection system (named RoTriDeS). This system is suitable to detect the triggering accuracy of global shutter cameras. As a result, the wired system indicated an 8.91 μs mean triggering time difference between two cameras. Corresponding mean values for the four wireless triggering systems varied between 7.92 and 9.42 μs. Presented values include both camera-based and trigger-based desynchronization. Arduino-based triggering systems appeared to be feasible, and they have the potential to be extended to more complicated triggering systems.

  12. Prompt triggering of edge localized modes through lithium granule injection on EAST

    Science.gov (United States)

    Lunsford, Robert; Sun, Z.; Hu, J. S.; Xu, W.; Zuo, G. Z.; Gong, X. Z.; Wan, B. N.; Li, J. G.; Huang, M.; Maingi, R.; Diallo, A.; Tritz, K.; the EAST Team

    2017-10-01

    We report successful triggering of edge localized mode (ELMs) in EAST with Lithium (Li) micropellets, and the observed dependence of ELM triggering efficiency on granule size. ELM control is essential for successful ITER operation throughout the entire campaign, relying on magnetic perturbations for ELM suppression and ELM frequency enhancement via pellet injection. To separate the task of fueling from ELM pacing, we initiate the prompt generation of ELMs via impurity granule injection. Lithium granules ranging in size from 200 - 1000 microns are mechanically injected into upper-single null EAST long pulse H-mode discharges. The injections are monitored for their effect on high Z impurity accumulation and to assess the pressure perturbation required for reliable ELM triggering. We have determined that granules of diameter larger than 600 microns (corresponding to 5.2 x 1018 Li atoms) are successful at triggering ELMs more than 90% of the time. The triggering efficiency drops precipitously to less than 40% as the granule size is reduced to 400 microns (1.5 x 1018 Li atoms), indicating a triggering threshold has been crossed. Using this information an optimal impurity granule size which will regularly trigger a prompt ELM in these EAST discharges is determined. Coupling these results with alternate discharge scenarios on EAST and similar experiments performed on DIII-D provides the possibility of extrapolation to future devices.

  13. Triggers of oral lichen planus flares and the potential role of trigger avoidance in disease management.

    Science.gov (United States)

    Chen, Hannah X; Blasiak, Rachel; Kim, Edwin; Padilla, Ricardo; Culton, Donna A

    2017-09-01

    Many patients with oral lichen planus (OLP) report triggers of flares, some of which overlap with triggers of other oral diseases, including oral allergy syndrome and oral contact dermatitis. The purpose of this study was to evaluate the prevalence of commonly reported triggers of OLP flares, their overlap with triggers of other oral diseases, and the potential role of trigger avoidance as a management strategy. Questionnaire-based survey of 51 patients with biopsy-proven lichen planus with oral involvement seen in an academic dermatology specialty clinic and/or oral pathology clinic between June 2014 and June 2015. Of the participants, 94% identified at least one trigger of their OLP flares. Approximately half of the participants (51%) reported at least one trigger that overlapped with known triggers of oral allergy syndrome, and 63% identified at least one trigger that overlapped with known triggers of oral contact dermatitis. Emotional stress was the most commonly reported trigger (77%). Regarding avoidance, 79% of the study participants reported avoiding their known triggers in daily life. Of those who actively avoided triggers, 89% reported an improvement in symptoms and 70% reported a decrease in the frequency of flares. Trigger identification and avoidance can play a potentially effective role in the management of OLP. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Upper airway evaluation

    International Nuclear Information System (INIS)

    Hoffman, E.A.; Gefter, W.B.; Schnall, M.; Nordberg, J.; Listerud, J.; Lenkinski, R.E.

    1988-01-01

    The authors are evaluating upper-airway sleep disorders with magnetic resonance (MR) imaging and x-ray cine computed tomography (CT). Fixed structural anatomy is visualized with multisection spin-echo MR imaging, the dynamic component with cine CT. Unique aspects of the study are described in this paper

  15. Application of Vector Triggering Random Decrement

    DEFF Research Database (Denmark)

    Asmussen, J. C.; Ibrahim, S. R.; Brincker, Rune

    result is a Random Decrement function from each measurement. In traditional Random Decrement estimation the triggering condition is a scalar condition, which should only be fulfilled in a single measurement. In vector triggering Random Decrement the triggering condition is a vector condition......This paper deals with applications of the vector triggering Random Decrement technique. This technique is new and developed with the aim of minimizing estimation time and identification errors. The theory behind the technique is discussed in an accompanying paper. The results presented...... in this paper should be regarded as a further documentation of the technique. The key point in Random Decrement estimation is the formulation of a triggering condition. If the triggering condition is fulfilled a time segment from each measurement is picked out and averaged with previous time segments. The final...

  16. Application of Vector Triggering Random Decrement

    DEFF Research Database (Denmark)

    Asmussen, J. C.; Ibrahim, S. R.; Brincker, Rune

    1997-01-01

    result is a Random Decrement function from each measurement. In traditional Random Decrement estimation the triggering condition is a scalar condition, which should only be fulfilled in a single measurement. In vector triggering Random Decrement the triggering condition is a vector condition......This paper deals with applications of the vector triggering Random Decrement technique. This technique is new and developed with the aim of minimizing estimation time and identification errors. The theory behind the technique is discussed in an accompanying paper. The results presented...... in this paper should be regarded as a further documentation of the technique. The key point in Random Decrement estimation is the formulation of a triggering condition. If the triggering condition is fulfilled a time segment from each measurement is picked out and averaged with previous time segments. The final...

  17. Smart trigger logic for focal plane arrays

    Science.gov (United States)

    Levy, James E; Campbell, David V; Holmes, Michael L; Lovejoy, Robert; Wojciechowski, Kenneth; Kay, Randolph R; Cavanaugh, William S; Gurrieri, Thomas M

    2014-03-25

    An electronic device includes a memory configured to receive data representing light intensity values from pixels in a focal plane array and a processor that analyzes the received data to determine which light values correspond to triggered pixels, where the triggered pixels are those pixels that meet a predefined set of criteria, and determines, for each triggered pixel, a set of neighbor pixels for which light intensity values are to be stored. The electronic device also includes a buffer that temporarily stores light intensity values for at least one previously processed row of pixels, so that when a triggered pixel is identified in a current row, light intensity values for the neighbor pixels in the previously processed row and for the triggered pixel are persistently stored, as well as a data transmitter that transmits the persistently stored light intensity values for the triggered and neighbor pixels to a data receiver.

  18. Triggering of the Largest Deccan Eruptions by the Chicxulub Impact

    Science.gov (United States)

    Richards, M. A.; Alvarez, W.; Self, S.; Karlstrom, L.; Renne, P. R.; Manga, M.; Sprain, C. J.; Smit, J.; Vanderkluysen, L.; Gibson, S. A.

    2015-12-01

    Modern constraints on the timing of the Cretaceous-Paleogene (K-Pg) mass extinction and the Chicxulub impact, together with a particularly voluminous and apparently brief eruptive pulse toward the end of the "main-stage" eruptions of the Deccan continental flood basalt province, suggest that these three events may have occurred within less than about a hundred thousand years of each other. Partial melting induced by the Chicxulub event does not provide an energetically plausible explanation for this remarkable coincidence, and both geochronologic and magnetic-polarity data show that Deccan volcanism was underway well before Chicxulub/K-Pg time. However, historical data show that in some cases eruptions from existing volcanic systems are triggered by earthquakes. Seismic modeling of the ground motion due to the Chicxulub impact suggests that the resulting Mw~11 earthquake could have generated seismic energy densities of at least 0.1-1.0 J/m3 throughout the upper ~200 km of the Earth's mantle, sufficient to trigger volcanic eruptions worldwide based upon comparison with historical examples. Triggering may have been caused by a transient increase in the effective permeability of the existing deep magmatic system beneath the Deccan province, or mantle plume "head." We suggest that the Chicxulub impact triggered the enormous Poladpur, Ambenali, and Mahabaleshwar (Wai sub-group) lava flows that may account for >70% of the Deccan Traps main-stage eruptions. This hypothesis is consistent with independent stratigraphic, geochronologic, geochemical, and tectonic constraints, which combine to indicate that at approximately Chicxulub/K-Pg time a huge pulse of mantle plume-derived magma passed through the crust with little interaction, and erupted to form the most extensive and voluminous lava flows known on Earth. This impact-induced pulse of volcanism may have enhanced the K-Pg extinction event, and/or suppressed post-extinction biotic recovery. High-precision radioisotopic

  19. The STAR Level-3 trigger system

    International Nuclear Information System (INIS)

    Adler, C.; Berger, J.; Demello, M.; Dietel, T.; Flierl, D.; Landgraf, J.; Lange, J.S.; LeVine, M.J.; Ljubicic, A.; Nelson, J.; Roehrich, D.; Stock, R.; Struck, C.; Yepes, P.

    2003-01-01

    The STAR Level-3 trigger issues a trigger decision upon a complete online reconstruction of Au+Au collisions at relativistic heavy ion collider energies. Central interactions are processed up to a rate of 50 s -1 including a simple analysis of physics observables. The setup of the processor farm and the event reconstruction as well as experiences and the proposed trigger algorithms are described

  20. Upgrade trigger & reconstruction strategy: 2017 milestone

    CERN Document Server

    Albrecht, Johannes; Campora Perez, Daniel Hugo; Cattaneo, Marco; Marco, Clemencic; Couturier, Ben; Dziurda, Agnieszka; Fitzpatrick, Conor; Fontana, Marianna; Grillo, Lucia; Hasse, Christoph; Hill, Donal; Jones, Christopher Rob; Lemaitre, Florian; Lupton, Olli; Matev, Rosen; Pearce, Alex; Polci, Francesco; Promberger, Laura; Ponce, Sebastien; Quagliani, Renato; Raven, Gerhard; Sciascia, Barbara; Schiller, Manuel Tobias; Stahl, Sascha; Szymanski, Maciej Pawel; Chefdeville, Maximilien

    2018-01-01

    The LHCb collaboration is currently preparing an update of the experiment to take data in Run 3 of the LHC. The dominant feature of this upgrade is a trigger-less readout of the full detector followed by a full software trigger. To make optimal use of the collected data, the events are reconstructed at the inelastic collision rate of 30 MHz. This document presents the baseline trigger and reconstruction strategy as of the end of 2017.

  1. A muon trigger for the MACRO apparatus

    International Nuclear Information System (INIS)

    Barbarito, E.; Bellotti, R.; Calicchio, M.; Castellano, M.; DeCataldo, G.; DeMarzo, C.; Erriquez, O.; Favuzzi, C.; Giglietto, N.; Liuzzi, R.; Spinelli, P.

    1991-01-01

    A trigger circuit based on EPROM components, able to manage up to 30 lines from independent counters, is described. The circuit has been designed and used in the MACRO apparatus at the Gran Sasso Laboratory for triggering on fast particles. The circuit works with standard TTL positive logic and is assembled in a double standard CAMAC module. It has a high triggering capacity and a high flexibility. (orig.)

  2. The ATLAS Level-1 Calorimeter Trigger

    International Nuclear Information System (INIS)

    Achenbach, R; Andrei, V; Adragna, P; Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J P; Asman, B; Bohm, C; Ay, C; Bauss, B; Bendel, M; Dahlhoff, A; Eckweiler, S; Booth, J R A; Thomas, P Bright; Charlton, D G; Collins, N J; Curtis, C J

    2008-01-01

    The ATLAS Level-1 Calorimeter Trigger uses reduced-granularity information from all the ATLAS calorimeters to search for high transverse-energy electrons, photons, τ leptons and jets, as well as high missing and total transverse energy. The calorimeter trigger electronics has a fixed latency of about 1 μs, using programmable custom-built digital electronics. This paper describes the Calorimeter Trigger hardware, as installed in the ATLAS electronics cavern

  3. The ATLAS Level-1 Calorimeter Trigger

    Energy Technology Data Exchange (ETDEWEB)

    Achenbach, R; Andrei, V [Kirchhoff-Institut fuer Physik, University of Heidelberg, D-69120 Heidelberg (Germany); Adragna, P [Physics Department, Queen Mary, University of London, London E1 4NS (United Kingdom); Apostologlou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J P [STFC Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot, Oxon OX11 0QX (United Kingdom); Asman, B; Bohm, C [Fysikum, Stockholm University, SE-106 91 Stockholm (Sweden); Ay, C; Bauss, B; Bendel, M; Dahlhoff, A; Eckweiler, S [Institut fuer Physik, University of Mainz, D-55099 Mainz (Germany); Booth, J R A; Thomas, P Bright; Charlton, D G; Collins, N J; Curtis, C J [School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom)], E-mail: e.eisenhandler@qmul.ac.uk (and others)

    2008-03-15

    The ATLAS Level-1 Calorimeter Trigger uses reduced-granularity information from all the ATLAS calorimeters to search for high transverse-energy electrons, photons, {tau} leptons and jets, as well as high missing and total transverse energy. The calorimeter trigger electronics has a fixed latency of about 1 {mu}s, using programmable custom-built digital electronics. This paper describes the Calorimeter Trigger hardware, as installed in the ATLAS electronics cavern.

  4. Upper Extremity Muscle Activity During In-Phase and Anti-Phase Continuous Pushing Tasks.

    Science.gov (United States)

    Gruevski, Kristina M; Hodder, Joanne N; Keir, Peter J

    2017-11-01

    To determine the effect of anti-phase, in-phase bimanual and unimanual simulated industrial pushing tasks and frequency on upper extremity muscle activity. Research investigating symmetrical (in-phase) and asymmetrical (anti-phase) pushing exertions is limited despite a high prevalence in industry. Fifteen female participants completed five pushing tasks using a dual handle apparatus at three frequencies: 15 cycles per minute (cpm), 30 cpm, and self-selected. Tasks included two bimanual symmetrical pushes (constrained and unconstrained), two bimanual asymmetrical pushes (reciprocating and continuous), and one right unimanual push. Surface electromyography (EMG) from the right anterior, middle, and posterior deltoid (AD, MD, and PD); right and left trapezius (RT and LT); right pectoralis major (PM); and right and left external obliques (REO and LEO) was collected and normalized to maximum voluntary effort. There was a task by frequency interaction in the AD, MD, PD, and RT ( p pushes and constrained, in-phase pushes had the highest muscle activity demands and the least amount of variability in muscle activity and therefore may present the greatest risk of injury. Anti-phase pushing is known to have a greater cognitive demand, and this study demonstrated that it also has a greater physical demand when performed continuously.

  5. The ATLAS Trigger System Commissioning and Performance

    CERN Document Server

    Hamilton, A

    2010-01-01

    The ATLAS trigger has been used very successfully to collect collision data during 2009 and 2010 LHC running at centre of mass energies of 900 GeV, 2.36 TeV, and 7 TeV. This paper presents the ongoing work to commission the ATLAS trigger with proton collisions, including an overview of the performance of the trigger based on extensive online running. We describe how the trigger has evolved with increasing LHC luminosity and give a brief overview of plans for forthcoming LHC running.

  6. The ATLAS Muon and Tau Trigger

    CERN Document Server

    Dell'Asta, L; The ATLAS collaboration

    2013-01-01

    [Muon] The ATLAS experiment at CERN's Large Hadron Collider (LHC) deploys a three-levels processing scheme for the trigger system. The level-1 muon trigger system gets its input from fast muon trigger detectors. Fast sector logic boards select muon candidates, which are passed via an interface board to the central trigger processor and then to the High Level Trigger (HLT). The muon HLT is purely software based and encompasses a level-2 (L2) trigger followed by an event filter (EF) for a staged trigger approach. It has access to the data of the precision muon detectors and other detector elements to refine the muon hypothesis. Trigger-specific algorithms were developed and are used for the L2 to increase processing speed for instance by making use of look-up tables and simpler algorithms, while the EF muon triggers mostly benefit from offline reconstruction software to obtain most precise determination of the track parameters. There are two algorithms with different approaches, namely inside-out and outside-in...

  7. Data analysis at Level-1 Trigger level

    CERN Document Server

    Wittmann, Johannes; Aradi, Gregor; Bergauer, Herbert; Jeitler, Manfred; Wulz, Claudia; Apanasevich, Leonard; Winer, Brian; Puigh, Darren Michael

    2017-01-01

    With ever increasing luminosity at the LHC, optimum online data selection is getting more and more important. While in the case of some experiments (LHCb and ALICE) this task is being completely transferred to computer farms, the others - ATLAS and CMS - will not be able to do this in the medium-term future for technological, detector-related reasons. Therefore, these experiments pursue the complementary approach of migrating more and more of the offline and High-Level Trigger intelligence into the trigger electronics. This paper illustrates how the Level-1 Trigger of the CMS experiment and in particular its concluding stage, the Global Trigger, take up this challenge.

  8. The Run-2 ATLAS Trigger System

    International Nuclear Information System (INIS)

    Martínez, A Ruiz

    2016-01-01

    The ATLAS trigger successfully collected collision data during the first run of the LHC between 2009-2013 at different centre-of-mass energies between 900 GeV and 8TeV. The trigger system consists of a hardware Level-1 and a software-based high level trigger (HLT) that reduces the event rate from the design bunch-crossing rate of 40 MHz to an average recording rate of a few hundred Hz. In Run-2, the LHC will operate at centre-of-mass energies of 13 and 14 TeV and higher luminosity, resulting in up to five times higher rates of processes of interest. A brief review of the ATLAS trigger system upgrades that were implemented between Run-1 and Run-2, allowing to cope with the increased trigger rates while maintaining or even improving the efficiency to select physics processes of interest, will be given. This includes changes to the Level-1 calorimeter and muon trigger systems, the introduction of a new Level-1 topological trigger module and the merging of the previously two-level HLT system into a single event processing farm. A few examples will be shown, such as the impressive performance improvements in the HLT trigger algorithms used to identify leptons, hadrons and global event quantities like missing transverse energy. Finally, the status of the commissioning of the trigger system and its performance during the 2015 run will be presented. (paper)

  9. Geometrical Acceptance Analysis for RPC PAC Trigger

    CERN Document Server

    Seo, Eunsung

    2010-01-01

    The CMS(Compact Muon Solenoid) is one of the four experiments that will analyze the collision results of the protons accelerated by the Large Hardron Collider(LHC) at CERN(Conseil Europen pour la Recherche Nuclaire). In case of the CMS experiment, the trigger system is divided into two stages : The Level-1 Trigger and High Level Trigger. The RPC(Resistive Plate Chamber) PAC(PAttern Comparator) Trigger system, which is a subject of this thesis, is a part of the Level-1 Muon Trigger System. Main task of the PAC Trigger is to identify muons, measures transverse momenta and select the best muon candidates for each proton bunch collision occurring every 25 ns. To calculate the value of PAC Trigger efficiency for triggerable muon, two terms of different efficiencies are needed ; acceptance efficiency and chamber efficiency. Main goal of the works described in this thesis is obtaining the acceptance efficiency of the PAC Trigger in each logical cone. Acceptance efficiency is a convolution of the chambers geometry an...

  10. Landslide triggering by rain infiltration

    Science.gov (United States)

    Iverson, Richard M.

    2000-01-01

    Landsliding in response to rainfall involves physical processes that operate on disparate timescales. Relationships between these timescales guide development of a mathematical model that uses reduced forms of Richards equation to evaluate effects of rainfall infiltration on landslide occurrence, timing, depth, and acceleration in diverse situations. The longest pertinent timescale is A/D0, where D0 is the maximum hydraulic diffusivity of the soil and A is the catchment area that potentially affects groundwater pressures at a prospective landslide slip surface location with areal coordinates x, y and depth H. Times greater than A/D0 are necessary for establishment of steady background water pressures that develop at (x, y, H) in response to rainfall averaged over periods that commonly range from days to many decades. These steady groundwater pressures influence the propensity for landsliding at (x, y, H), but they do not trigger slope failure. Failure results from rainfall over a typically shorter timescale H2/D0 associated with transient pore pressure transmission during and following storms. Commonly, this timescale ranges from minutes to months. The shortest timescale affecting landslide responses to rainfall is √(H/g), where g is the magnitude of gravitational acceleration. Postfailure landslide motion occurs on this timescale, which indicates that the thinnest landslides accelerate most quickly if all other factors are constant. Effects of hydrologic processes on landslide processes across these diverse timescales are encapsulated by a response function, R(t*) = √(t*/π) exp (-1/t*) - erfc (1/√t*), which depends only on normalized time, t*. Use of R(t*) in conjunction with topographic data, rainfall intensity and duration information, an infinite-slope failure criterion, and Newton's second law predicts the timing, depth, and acceleration of rainfall-triggered landslides. Data from contrasting landslides that exhibit rapid, shallow

  11. The effect of lift teams on kinematics and muscle activity of the upper extremity and trunk in bricklayers.

    Science.gov (United States)

    Anton, Dan; Mizner, Ryan L; Hess, Jennifer A

    2013-04-01

    Workplace-simulation study using a crossover design. To evaluate the effect of lift teams on trunk and upper extremity kinematics and muscle activity among bricklayers. Healthcare practitioners often instruct individuals with work-related musculoskeletal disorders in proper lifting techniques. Bricklayers are especially affected by lifting-related musculoskeletal disorders. Lift teams are a possible intervention for reducing exposure to heavy lifting. Eighteen apprentice bricklayers constructed walls with concrete blocks alone (1 person) and in 2-person lift teams. Peak shoulder and trunk kinematics and normalized mean surface electromyography of the upper trapezius, lumbar paraspinals, and flexor forearm muscles were collected bilaterally. Differences between construction methods and rows 1, 3, and 6 of the wall were calculated with repeated-measures analyses of variance. Working in lift teams required less trunk flexion (P = .008) at row 1 but more sidebending at row 6 (Pteam workers. Lift-team peak shoulder flexion was lower at row 3 (P = .002), whereas abduction was higher at rows 1 (P = .007) and 6 (Pteams at row 6 (Pteams at all rows (P≤.002). Working in lift teams may be a beneficial intervention for reducing trunk flexion and lumbar paraspinal activity when bricklayers work at heights between the knees and waist, but lift teams are not recommended at higher working heights.

  12. Nonlinear dynamical triggering of slow slip

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Paul A [Los Alamos National Laboratory; Knuth, Matthew W [WISCONSIN; Kaproth, Bryan M [PENN STATE; Carpenter, Brett [PENN STATE; Guyer, Robert A [Los Alamos National Laboratory; Le Bas, Pierre - Yves [Los Alamos National Laboratory; Daub, Eric G [Los Alamos National Laboratory; Marone, Chris [PENN STATE

    2010-12-10

    Among the most fascinating, recent discoveries in seismology have been the phenomena of triggered slip, including triggered earthquakes and triggered-tremor, as well as triggered slow, silent-slip during which no seismic energy is radiated. Because fault nucleation depths cannot be probed directly, the physical regimes in which these phenomena occur are poorly understood. Thus determining physical properties that control diverse types of triggered fault sliding and what frictional constitutive laws govern triggered faulting variability is challenging. We are characterizing the physical controls of triggered faulting with the goal of developing constitutive relations by conducting laboratory and numerical modeling experiments in sheared granular media at varying load conditions. In order to simulate granular fault zone gouge in the laboratory, glass beads are sheared in a double-direct configuration under constant normal stress, while subject to transient perturbation by acoustic waves. We find that triggered, slow, silent-slip occurs at very small confining loads ({approx}1-3 MPa) that are smaller than those where dynamic earthquake triggering takes place (4-7 MPa), and that triggered slow-slip is associated with bursts of LFE-like acoustic emission. Experimental evidence suggests that the nonlinear dynamical response of the gouge material induced by dynamic waves may be responsible for the triggered slip behavior: the slip-duration, stress-drop and along-strike slip displacement are proportional to the triggering wave amplitude. Further, we observe a shear-modulus decrease corresponding to dynamic-wave triggering relative to the shear modulus of stick-slips. Modulus decrease in response to dynamical wave amplitudes of roughly a microstrain and above is a hallmark of elastic nonlinear behavior. We believe that the dynamical waves increase the material non-affine elastic deformation during shearing, simultaneously leading to instability and slow-slip. The inferred

  13. The trigger supervisor: Managing triggering conditions in a high energy physics experiment

    International Nuclear Information System (INIS)

    Wadsworth, B.; Lanza, R.; LeVine, M.J.; Scheetz, R.A.; Videbaek, F.

    1987-01-01

    A trigger supervisor, implemented in VME-bus hardware, is described, which enables the host computer to dynamically control and monitor the trigger configuration for acquiring data from multiple detector partitions in a complex experiment

  14. Upper urinary tract tumors

    DEFF Research Database (Denmark)

    Gandrup, Karen L; Nordling, Jørgen; Balslev, Ingegerd

    2014-01-01

    BACKGROUND: Computed tomography urography (CTU) is used widely in the work-up of patients with symptoms of urinary tract lesions. Preoperative knowledge of whether a tumor is invasive or non-invasive is important for the choice of surgery. So far there are no studies about the distinction...... of invasive and non-invasive tumors in ureter and renal pelvis based on the enhancement measured with Hounsfield Units. PURPOSE: To examine the value of CTU using split-bolus technique to distinguish non-invasive from invasive urothelial carcinomas in the upper urinary tract. MATERIAL AND METHODS: Patients...... obtained at CTU could distinguish between invasive and non-invasive lesions. No patients had a CTU within the last year before the examination that resulted in surgery. CONCLUSION: A split-bolus CTU cannot distinguish between invasive and non-invasive urothelial tumors in the upper urinary tract...

  15. Simulation studies for optimizing the trigger generation criteria for the TACTIC telescope

    International Nuclear Information System (INIS)

    Koul, M.K.; Tickoo, A.K.; Dhar, V.K.; Venugopal, K.; Chanchalani, K.; Rannot, R.C.; Yadav, K.K.; Chandra, P.; Kothari, M.; Koul, R.

    2011-01-01

    In this paper, we present the results of Monte Carlo simulations of γ-ray and cosmic-ray proton induced extensive air showers as detected by the TACTIC atmospheric Cherenkov imaging telescope for optimizing its trigger field of view and topological trigger generation scheme. The simulation study has been carried out at several zenith angles. The topological trigger generation uses a coincidence of two or three nearest neighbor pixels for producing an event trigger. The results of this study suggest that a trigger field of 11x11 pixels (∼3.4 0 x3.4 0 ) is quite optimum for achieving maximum effective collection area for γ-rays from a point source. With regard to optimization of topological trigger generation, it is found that both two and three nearest neighbor pixels yield nearly similar results up to a zenith angle of 25 0 with a threshold energy of ∼1.5TeV for γ-rays. Beyond zenith angle of 25 0 , the results suggest that a two-pixel nearest neighbor trigger should be preferred. Comparison of the simulated integral rates has also been made with corresponding measured values for validating the predictions of the Monte Carlo simulations, especially the effective collection area, so that energy spectra of sources (or flux upper limits in case of no detection) can be determined reliably. Reasonably good matching of the measured trigger rates (on the basis of ∼207h of data collected with the telescope in NN-2 and NN-3 trigger configurations) with that obtained from simulations reassures that the procedure followed by us in estimating the threshold energy and detection rates is quite reliable. - Highlights: → Optimization of the trigger field of view and topological trigger generation for the TACTIC telescope. → Monte Carlo simulations of extensive air showers carried out using CORSIKA code. → Trigger generation with two or three nearest neighbor pixels yield similar results up to a zenith angle of 25 deg. → Reasonably good matching of measured trigger

  16. Tools for Trigger Aware Analyses in ATLAS

    CERN Document Server

    Krasznahorkay, A; The ATLAS collaboration; Stelzer, J

    2010-01-01

    In order to search for rare processes, all four LHC experiments have to use advanced triggering methods for selecting and recording the events of interest. At the expected nominal LHC operating conditions only about 0.0005% of the collision events can be kept for physics analysis in ATLAS. Therefore the understanding and evaluation of the trigger performance is one of the most crucial parts of any physics analysis. ATLAS’s first level trigger is composed of custom-built hardware, while the second and third levels are implemented using regular PCs running reconstruction and selection algorithms. Because of this split, accessing the results of the trigger execution for the two stages is different. The complexity of the software trigger presents further difficulties in accessing the trigger data. To make the job of the physicists easier when evaluating the trigger performance, multiple general-use tools are provided by the ATLAS Trigger Analysis Tools group. The TrigDecisionTool, a general tool, is provided to...

  17. The Run-2 ATLAS Trigger System

    CERN Document Server

    Ruiz-Martinez, Aranzazu; The ATLAS collaboration

    2016-01-01

    The ATLAS trigger has been successfully collecting collision data during the first run of the LHC between 2009-2013 at a centre-of-mass energy between 900 GeV and 8 TeV. The trigger system consists of a hardware Level-1 (L1) and a software based high-level trigger (HLT) that reduces the event rate from the design bunch-crossing rate of 40 MHz to an average recording rate of a few hundred Hz. In Run-2, the LHC will operate at centre-of-mass energies of 13 and 14 TeV resulting in roughly five times higher trigger rates. We will briefly review the ATLAS trigger system upgrades that were implemented during the shutdown, allowing us to cope with the increased trigger rates while maintaining or even improving our efficiency to select relevant physics processes. This includes changes to the L1 calorimeter and muon trigger systems, the introduction of a new L1 topological trigger module and the merging of the previously two-level HLT system into a single event filter farm. At hand of a few examples, we will show the ...

  18. The Run-2 ATLAS Trigger System

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00222798; The ATLAS collaboration

    2016-01-01

    The ATLAS trigger successfully collected collision data during the first run of the LHC between 2009-2013 at different centre-of-mass energies between 900 GeV and 8 TeV. The trigger system consists of a hardware Level-1 and a software-based high level trigger (HLT) that reduces the event rate from the design bunch-crossing rate of 40 MHz to an average recording rate of a few hundred Hz. In Run-2, the LHC will operate at centre-of-mass energies of 13 and 14 TeV and higher luminosity, resulting in roughly five times higher trigger rates. A brief review of the ATLAS trigger system upgrades that were implemented between Run-1 and Run-2, allowing to cope with the increased trigger rates while maintaining or even improving the efficiency to select physics processes of interest, will be given. This includes changes to the Level-1 calorimeter and muon trigger systems, the introduction of a new Level-1 topological trigger module and the merging of the previously two-level HLT system into a single event filter farm. A ...

  19. Intelligent trigger processor for the crystal box

    International Nuclear Information System (INIS)

    Sanders, G.H.; Butler, H.S.; Cooper, M.D.

    1981-01-01

    A large solid angle modular NaI(Tl) detector with 432 phototubes and 88 trigger scintillators is being used to search simultaneously for three lepton flavor changing decays of muon. A beam of up to 10 6 muons stopping per second with a 6% duty factor would yield up to 1000 triggers per second from random triple coincidences. A reduction of the trigger rate to 10 Hz is required from a hardwired primary trigger processor described in this paper. Further reduction to < 1 Hz is achieved by a microprocessor based secondary trigger processor. The primary trigger hardware imposes voter coincidence logic, stringent timing requirements, and a non-adjacency requirement in the trigger scintillators defined by hardwired circuits. Sophisticated geometric requirements are imposed by a PROM-based matrix logic, and energy and vector-momentum cuts are imposed by a hardwired processor using LSI flash ADC's and digital arithmetic loci. The secondary trigger employs four satellite microprocessors to do a sparse data scan, multiplex the data acquisition channels and apply additional event filtering

  20. Trigger factors for familial hemiplegic migraine

    DEFF Research Database (Denmark)

    Hansen, Jakob Møller; Hauge, Anne Werner; Ashina, Messoud

    2011-01-01

    The aim was to identify and describe migraine trigger factors in patients with familial hemiplegic migraine (FHM) from a population-based sample.......The aim was to identify and describe migraine trigger factors in patients with familial hemiplegic migraine (FHM) from a population-based sample....

  1. The ATLAS Level-1 Topological Trigger Performance

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00371751; The ATLAS collaboration

    2016-01-01

    The LHC will collide protons in the ATLAS detector with increasing luminosity through 2016, placing stringent operational and physical requirements to the ATLAS trigger system in order to reduce the 40 MHz collision rate to a manageable event storage rate of 1 kHz, while not rejecting interesting physics events. The Level-1 trigger is the first rate-reducing step in the ATLAS trigger system with an output rate of 100 kHz and decision latency smaller than 2.5 μs. It consists of a calorimeter trigger, muon trigger and a central trigger processor. During the LHC shutdown after the Run 1 finished in 2013, the Level-1 trigger system was upgraded including hardware, firmware and software updates. In particular, new electronics modules were introduced in the real-time data processing path: the Topological Processor System (L1Topo). It consists of a single AdvancedCTA shelf equipped with two Level-1 topological processor blades. They receive real-time information from the Level-1 calorimeter and muon triggers, which...

  2. Do episodes of anger trigger myocardial infarction?

    DEFF Research Database (Denmark)

    Möller, J; Hallqvist, J; Diderichsen, Finn

    1999-01-01

    Our objectives were to study anger as a trigger of acute myocardial infarction (MI) and to explore potential effect modification by usual behavioral patterns related to hostility.......Our objectives were to study anger as a trigger of acute myocardial infarction (MI) and to explore potential effect modification by usual behavioral patterns related to hostility....

  3. Triggering soft bombs at the LHC

    Science.gov (United States)

    Knapen, Simon; Griso, Simone Pagan; Papucci, Michele; Robinson, Dean J.

    2017-08-01

    Very high multiplicity, spherically-symmetric distributions of soft particles, with p T ˜ few×100 MeV, may be a signature of strongly-coupled hidden valleys that exhibit long, efficient showering windows. With traditional triggers, such `soft bomb' events closely resemble pile-up and are therefore only recorded with minimum bias triggers at a very low efficiency. We demonstrate a proof-of-concept for a high-level triggering strategy that efficiently separates soft bombs from pile-up by searching for a `belt of fire': a high density band of hits on the innermost layer of the tracker. Seeding our proposed high-level trigger with existing jet, missing transverse energy or lepton hardware-level triggers, we show that net trigger efficiencies of order 10% are possible for bombs of mass several × 100 GeV. We also consider the special case that soft bombs are the result of an exotic decay of the 125 GeV Higgs. The fiducial rate for `Higgs bombs' triggered in this manner is marginally higher than the rate achievable by triggering directly on a hard muon from associated Higgs production.

  4. The LVL2 trigger goes online

    CERN Multimedia

    David Berge

    On Friday, the 9th of February, the ATLAS TDAQ community reached an important milestone. In a successful integration test, cosmic-ray muons were recorded with parts of the muon spectrometer, the central-trigger system and a second-level trigger algorithm. This was actually the first time that a full trigger slice all the way from the first-level trigger muon chambers up to event building after event selection by the second-level trigger ran online with cosmic rays. The ATLAS trigger and data acquisition system has a three-tier structure that is designed to cope with the enormous demands of proton-proton collisions at a bunch-crossing frequency of 40 MHz, with a typical event size of 1-2 MB. The online event selection has to reduce the incoming rate by a factor of roughly 200,000 to 200 Hz, a rate digestible by the archival-storage and offline-processing facilities. ATLAS has a mixed system: the first-level trigger (LVL1) is in hardware, while the other two consecutive levels, the second-level trigger (LVL2)...

  5. Reliability model analysis and primary experimental evaluation of laser triggered pulse trigger

    International Nuclear Information System (INIS)

    Chen Debiao; Yang Xinglin; Li Yuan; Li Jin

    2012-01-01

    High performance pulse trigger can enhance performance and stability of the PPS. It is necessary to evaluate the reliability of the LTGS pulse trigger, so we establish the reliability analysis model of this pulse trigger based on CARMES software, the reliability evaluation is accord with the statistical results. (authors)

  6. A general-purpose trigger processor system and its application to fast vertex trigger

    International Nuclear Information System (INIS)

    Hazumi, M.; Banas, E.; Natkaniec, Z.; Ostrowicz, W.

    1997-12-01

    A general-purpose hardware trigger system has been developed. The system comprises programmable trigger processors and pattern generator/samplers. The hardware design of the system is described. An application as a prototype of the very fast vertex trigger in an asymmetric B-factory at KEK is also explained. (author)

  7. The ATLAS Level-1 Trigger Timing Setup

    CERN Document Server

    Spiwoks, R; Ellis, Nick; Farthouat, P; Gällnö, P; Haller, J; Krasznahorkay, A; Maeno, T; Pauly, T; Pessoa-Lima, H; Resurreccion-Arcas, I; Schuler, G; De Seixas, J M; Torga-Teixeira, R; Wengler, T

    2005-01-01

    The ATLAS detector at CERN's LHC will be exposed to proton-proton collisions at a bunch-crossing rate of 40 MHz. In order to reduce the data rate, a three-level trigger system selects potentially interesting physics. The first trigger level is implemented in electronics and firmware. It aims at reducing the output rate to less than 100 kHz. The Central Trigger Processor combines information from the calorimeter and muon trigger processors and makes the final Level-1-Accept decision. It is a central element in the timing setup of the experiment. Three aspects are considered in this article: the timing setup with respect to the Level-1 trigger, with respect to the expriment, and with respect to the world.

  8. MR imaging findings of trigger thumb

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Eric Y.; Chen, Karen C.; Chung, Christine B. [VA San Diego Healthcare System, Radiology Service, San Diego, CA (United States); University of California, San Diego Medical Center, Department of Radiology, San Diego, CA (United States)

    2015-08-15

    Trigger finger (or trigger thumb), also known as sclerosing tenosynovitis, is a common clinical diagnosis that rarely presents for imaging. Because of this selection bias, many radiologists may not be familiar with the process. Furthermore, patients who do present for imaging frequently have misleading examination indications. To our knowledge, magnetic resonance (MR) imaging findings of trigger thumb have not been previously reported in the literature. In this article, we review the entity of trigger thumb, the anatomy involved, and associated imaging findings, which include flexor pollicis longus tendinosis with a distinct nodule, A1 pulley thickening, and tenosynovitis. In addition, in some cases, an abnormal Av pulley is apparent. In the rare cases of trigger finger that present for MR imaging, accurate diagnosis by the radiologist can allow initiation of treatment and avoid further unnecessary workup. (orig.)

  9. MR imaging findings of trigger thumb

    International Nuclear Information System (INIS)

    Chang, Eric Y.; Chen, Karen C.; Chung, Christine B.

    2015-01-01

    Trigger finger (or trigger thumb), also known as sclerosing tenosynovitis, is a common clinical diagnosis that rarely presents for imaging. Because of this selection bias, many radiologists may not be familiar with the process. Furthermore, patients who do present for imaging frequently have misleading examination indications. To our knowledge, magnetic resonance (MR) imaging findings of trigger thumb have not been previously reported in the literature. In this article, we review the entity of trigger thumb, the anatomy involved, and associated imaging findings, which include flexor pollicis longus tendinosis with a distinct nodule, A1 pulley thickening, and tenosynovitis. In addition, in some cases, an abnormal Av pulley is apparent. In the rare cases of trigger finger that present for MR imaging, accurate diagnosis by the radiologist can allow initiation of treatment and avoid further unnecessary workup. (orig.)

  10. Pulse triggering mechanism of air proportional counters

    International Nuclear Information System (INIS)

    Aoyama, T.; Mori, T.; Watanabe, T.

    1983-01-01

    This paper describes the pulse triggering mechanism of a cylindrical proportional counter filled with air at atmospheric pressure for the incidence of β-rays. Experimental results indicate that primary electrons created distantly from the anode wire by a β-ray are transformed into negative ions, which then detach electrons close to the anode wire and generate electron avalanches thus triggering pulses, while electrons created near the anode wire by a β-ray directly trigger a pulse. Since a negative ion pulse is triggered by a single electron detached from a negative ion, multiple pulses are generated by a large number of ions produced by the incidence of a single β-ray. It is therefore necessary not to count pulses triggered by negative ions but to count those by primary electrons alone when use is made of air proportional counters for the detection of β-rays. (orig.)

  11. Concept of the CMS Trigger Supervisor

    CERN Document Server

    Magrans de Abril, Ildefons; Varela, Joao

    2006-01-01

    The Trigger Supervisor is an online software system designed for the CMS experiment at CERN. Its purpose is to provide a framework to set up, test, operate and monitor the trigger components on one hand and to manage their interplay and the information exchange with the run control part of the data acquisition system on the other. The Trigger Supervisor is conceived to provide a simple and homogeneous client interface to the online software infrastructure of the trigger subsystems. This document specifies the functional and non-functional requirements, design and operational details, and the components that will be delivered in order to facilitate a smooth integration of the trigger software in the context of CMS.

  12. Designing signal-enriched triggers for boosted jets.

    CERN Document Server

    Toumazou, Marina

    2017-01-01

    Triggers designed to favour the selection of hadronically decaying massive particles have been studied. Both triggers using solely ET and mass cuts (similar to new 2017 triggers) and triggers exploiting polarization information have been studied. The mass cut triggers show substantial gains in rate reduction, while the benefits of polarization triggers are less obvious. The final conclusion is that it is more useful to identify and trigger on generic boosted decays, irrespective of the polarization of the decaying particle

  13. in upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Sinan Uzman

    2016-07-01

    Full Text Available Introduction : There is increasing interest in sedation for upper gastrointestinal endoscopy (UGE. Prospective randomized studies comparing sedation properties and complications of propofol and midazolam/meperidine in upper gastrointestinal endoscopy (UGE are few. Aim: To compare propofol and midazolam/meperidine sedation for UGE in terms of cardiopulmonary side effects, patient and endoscopist satisfaction and procedure-related times. Material and methods: This was a prospective, randomized, double-blind study of propofol versus midazolam and meperidine in 100 patients scheduled for diagnostic upper gastrointestinal endoscopy. The patients were divided into propofol and midazolam/meperidine groups. Randomization was generated by a computer. Cardiopulmonary side effects (hypotension, bradycardia, hypoxemia, procedure-related times (endoscopy time, awake time, time to hospital discharge, and patient and endoscopist satisfaction were compared between groups. Results: There was no significant difference between the groups with respect to the cost, endoscopy time, or demographic and clinical characteristics of the patients. Awake time and time to hospital discharge were significantly shorter in the propofol group (6.58 ±4.72 vs. 9.32 ±4.26 min, p = 0.030 and 27.60 ±7.88 vs. 32.00 ±10.54 min, p = 0.019. Hypotension incidence was significantly higher in the propofol group (12% vs. 0%, p = 0.027. The patient and endoscopist satisfaction was better with propofol. Conclusions : Propofol may be preferred to midazolam/meperidine sedation, with a shorter awake and hospital discharge time and better patient and endoscopist satisfaction. However, hypotension risk should be considered with propofol, and careful evaluation is needed, particularly in cardiopulmonary disorders.

  14. Upper extremity golf injuries.

    Science.gov (United States)

    Cohn, Michael A; Lee, Steven K; Strauss, Eric J

    2013-01-01

    Golf is a global sport enjoyed by an estimated 60 million people around the world. Despite the common misconception that the risk of injury during the play of golf is minimal, golfers are subject to a myriad of potential pathologies. While the majority of injuries in golf are attributable to overuse, acute traumatic injuries can also occur. As the body's direct link to the golf club, the upper extremities are especially prone to injury. A thorough appreciation of the risk factors and patterns of injury will afford accurate diagnosis, treatment, and prevention of further injury.

  15. The ATLAS Electron and Photon Trigger

    CERN Document Server

    Jones, Samuel David; The ATLAS collaboration

    2017-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs boson. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based Level-1 trigger and a software-based high-level trigger, both of which were upgraded during the LHC shutdown in preparation for Run-2 operation. To cope with the increasing luminosity and more challenging pile-up conditions at a center-of-mass energy of 13 TeV, the trigger selections at each level are optimized to control the rates and keep efficiencies high. To achieve this goal multivariate analysis techniques are used. The ATLAS electron and photon triggers and their performance with Run 2 dat...

  16. The ATLAS Electron and Photon Trigger

    CERN Document Server

    Jones, Samuel David; The ATLAS collaboration

    2018-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs boson. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based Level-1 trigger and a software-based high-level trigger, both of which were upgraded during the LHC shutdown in preparation for Run-2 operation. To cope with the increasing luminosity and more challenging pile-up conditions at a center-of-mass energy of 13 TeV, the trigger selections at each level are optimized to control the rates and keep efficiencies high. To achieve this goal multivariate analysis techniques are used. The ATLAS electron and photon triggers and their performance with Run 2 dat...

  17. Upgrade of the CMS Global Muon Trigger

    CERN Document Server

    Jeitler, Manfred; Rabady, Dinyar; Sakulin, Hannes; Stahl, Achim

    2015-01-01

    The increase in center-of-mass energy and luminosity for Run-II of the Large Hadron Collider poses new challenges for the trigger systems of the experiments. To keep triggering with a similar performance as in Run-I, the CMS muon trigger is currently being upgraded. The new algorithms will provide higher resolution, especially for the muon transverse momentum and will make use of isolation criteria that combine calorimeter with muon information already in the level-1 trigger. The demands of the new algorithms can only be met by upgrading the level-1 trigger system to new powerful FPGAs with high bandwidth I/O. The processing boards will be based on the new μTCA standard. We report on the planned algorithms for the upgraded Global Muon Trigger (μGMT) which sorts and removes duplicates from boundaries of the muon trigger sub-systems. Furthermore, it determines how isolated the muon candidates are based on calorimetric energy deposits. The μGMT will be implemented using a processing board that features a larg...

  18. Upgrade of the CMS Global Muon Trigger

    CERN Document Server

    Lingemann, Joschka; Sakulin, Hannes; Jeitler, Manfred; Stahl, Achim

    2015-01-01

    The increase in center-of-mass energy and luminosity for Run 2 of the Large Hadron Collider pose new challenges for the trigger systems of the experiments. To keep triggering with a similar performance as in Run 1, the CMS muon trigger is currently being upgraded. The new algorithms will provide higher resolution, especially for the muon transverse momentum and will make use of isolation criteria that combine calorimeter with muon information already in the level-1 trigger. The demands of the new algorithms can only be met by upgrading the level-1 trigger system to new powerful FPGAs with high bandwidth I/O. The processing boards will be based on the new microTCA standard. We report on the planned algorithms for the upgraded Global Muon Trigger (GMT) which combines information from the muon trigger sub-systems and assigns the isolation variable. The upgraded GMT will be implemented using a Master Processor 7 card, built by Imperial College, that features a large Xilinx Virtex 7 FPGA. Up to 72 optical links at...

  19. The ZEUS calorimeter first level trigger

    International Nuclear Information System (INIS)

    Smith, W.H.; Ali, I.; Behrens, B.; Fordham, C.; Foudas, C.; Goussiou, A.; Jaworski, M.; Kinnel, T.; Lackey, J.; Robl, P.; Silverstein, S.; Dawson, J.W.; Krakauer, D.A.; Talaga, R.L.; Schlereth, J.L.

    1994-10-01

    The design of the ZEUS Calorimeter First Level Trigger (CFLT) is presented. The CFLT utilizes a pipelined architecture to provide trigger data for a global first leel trigger decision 5 μsec after each beam crossing, occurring every 96 nsec. The charges from 13K phototubes are summed into 1792 trigger tower pulseheights which are digitized by flash ADC's. The digital values are linearized, stored and used for sums and pattern tests. Summary data is forwarded to the Global First Level Trigger for each crossing 2 μsec after the crossing occurred. The CFLT determines the total energy, the total transverse energy, the missing energy, and the energy and number of isolated electrons and muons. It also provides information on the electromagnetic and hadronic energy deposited in various regions of the calorimeter. The CFLT has kept the experimental trigger rate below ∼200 Hz at the highest luminosity experienced at HERA. Performance studies suggest that the CFLT will keep the trigger rate below 1 kHZ against a rate of proton-beam gas interactions on the order of the 100 kHz expected at design luminosity. (orig.)

  20. The D0 run II trigger system

    International Nuclear Information System (INIS)

    Schwienhorst, Reinhard; Michigan State U.

    2004-01-01

    The D0 detector at the Fermilab Tevatron was upgraded for Run II. This upgrade included improvements to the trigger system in order to be able to handle the increased Tevatron luminosity and higher bunch crossing rates compared to Run I. The D0 Run II trigger is a highly exible system to select events to be written to tape from an initial interaction rate of about 2.5 MHz. This is done in a three-tier pipelined, buffered system. The first tier (level 1) processes fast detector pick-off signals in a hardware/firmware based system to reduce the event rate to about 1. 5kHz. The second tier (level 2) uses information from level 1 and forms simple Physics objects to reduce the rate to about 850 Hz. The third tier (level 3) uses full detector readout and event reconstruction on a filter farm to reduce the rate to 20-30 Hz. The D0 trigger menu contains a wide variety of triggers. While the emphasis is on triggering on generic lepton and jet final states, there are also trigger terms for specific final state signatures. In this document we describe the D0 trigger system as it was implemented and is currently operating in Run II

  1. Remote sensing observations of phytoplankton increases triggered by successive typhoons

    Science.gov (United States)

    Huang, Lei; Zhao, Hui; Pan, Jiayi; Devlin, Adam

    2017-12-01

    Phytoplankton blooms in the Western North Pacific, triggered by two successive typhoons with different intensities and translation speeds under different pre-existing oceanic conditions, were observed and analyzed using remotely sensed chlorophyll-a (Chl-a), sea surface temperature (SST), and sea surface height anomaly (SSHA) data, as well as typhoon parameters and CTD (conductivity, temperature, and depth) profiles. Typhoon Sinlaku, with relatively weaker intensity and slower translation speed, induced a stronger phytoplankton bloom than Jangmi with stronger intensity and faster translation speed (Chl-a>0.18 mg·m‒3 versus Chl-aTaiwan Island. Translation speed may be one of the important mechanisms that affect phytoplankton blooms in the study area. Pre-existing cyclonic circulations provided a relatively unstable thermodynamic structure for Sinlaku, and therefore cold water with rich nutrients could be brought up easily. The mixed-layer deepening caused by Typhoon Sinlaku, which occurred first, could have triggered an unfavorable condition for the phytoplankton bloom induced by Typhoon Jangmi which followed afterwards. The sea surface temperature cooling by Jangmi was suppressed due to the presence of the thick upper-ocean mixed-layer, which prevented the deeper cold water from being entrained into the upper-ocean mixed layer, leading to a weaker phytoplankton augment. The present study suggests that both wind (including typhoon translation speed and intensity) and pre-existing conditions (e.g., mixed-layer depths, eddies, and nutrients) play important roles in the strong phytoplankton bloom, and are responsible for the stronger phytoplankton bloom after Sinlaku's passage than that after Jangmi's passage. A new typhoon-influencing parameter is introduced that combines the effects of the typhoon forcing (including the typhoon intensity and translation speed) and the oceanic pre-condition. This parameter shows that the forcing effect of Sinlaku was stronger than

  2. ATLAS: triggers for B-physics

    International Nuclear Information System (INIS)

    George, Simon

    2000-01-01

    The LHC will produce bb-bar events at an unprecedented rate. The number of events recorded by ATLAS will be limited by the rate at which they can be stored offline and subsequently analysed. Despite the huge number of events, the small branching ratios mean that analysis of many of the most interesting channels for CP violation and other measurements will be limited by statistics. The challenge for the Trigger and Data Acquisition (DAQ) system is therefore to maximise the fraction of interesting B decays in the B-physics data stream. The ATLAS Trigger/DAQ system is split into three levels. The initial B-physics selection is made in the first-level trigger by an inclusive low-p T muon trigger (∼6 GeV). The second-level trigger strategy is based on identifying classes of final states by their partial reconstruction. The muon trigger is confirmed before proceeding to a track search. Electron/hadron separation is given by the transition radiation tracking detector and the Electromagnetic calorimeter. Muon identification is possible using the muon detectors and the hadronic calorimeter. From silicon strips, pixels and straw tracking, precise track reconstruction is used to make selections based on invariant mass, momentum and impact parameter. The ATLAS trigger group is currently engaged in algorithm development and performance optimisation for the B-physics trigger. This is closely coupled to the R and D programme for the higher-level triggers. Together the two programmes of work will optimise the hardware, architecture and algorithms to meet the challenging requirements. This paper describes the current status and progress of this work

  3. ELLERMAN BOMBS AT HIGH RESOLUTION. II. TRIGGERING, VISIBILITY, AND EFFECT ON UPPER ATMOSPHERE

    Energy Technology Data Exchange (ETDEWEB)

    Vissers, Gregal J. M.; Rouppe van der Voort, Luc H. M.; Rutten, Robert J., E-mail: g.j.m.vissers@astro.uio.no [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway)

    2013-09-01

    We use high-resolution imaging spectroscopy with the Swedish 1-m Solar Telescope (SST) to study the transient brightenings of the wings of the Balmer H{alpha} line in emerging active regions that are called Ellerman bombs. Simultaneous sampling of Ca II 8542 A with the SST confirms that most Ellerman bombs also occur in the wings of this line, but with markedly different morphology. Simultaneous images from the Solar Dynamics Observatory (SDO) show that Ellerman bombs are also detectable in the photospheric 1700 A continuum, again with differing morphology. They are also observable in 1600 A SDO images, but with much contamination from C IV emission in transition-region features. Simultaneous SST spectropolarimetry in Fe I 6301 A shows that Ellerman bombs occur at sites of strong-field magnetic flux cancellation between small bipolar strong-field patches that rapidly move together over the solar surface. Simultaneous SDO images in He II 304 A, Fe IX 171 A, and Fe XIV 211 A show no clear effect of the Ellerman bombs on the overlying transition region and corona. These results strengthen our earlier suggestion, based on H{alpha} morphology alone, that the Ellerman bomb phenomenon is a purely photospheric reconnection phenomenon.

  4. Trigger tracking for the LHCb upgrade

    CERN Multimedia

    Dungs, K

    2014-01-01

    This poster presents a trigger system for the upgraded LHCb detector, scheduled to begin operation in 2020. The proposed trigger system is implemented entirely in software. We show that track reconstruction of a similar quality to that available in the offline algorithms can be performed on the full inelastic pp-collision rate. A track finding efficiency of 98.8% relative to offline can be achieved for good trigger tracks. The CPU time required for this reconstruction is less than 60% of the available budget.

  5. The CMS Barrel Muon trigger upgrade

    International Nuclear Information System (INIS)

    Triossi, A.; Sphicas, P.; Bellato, M.; Montecassiano, F.; Ventura, S.; Ruiz, J.M. Cela; Bedoya, C. Fernandez; Tobar, A. Navarro; Fernandez, I. Redondo; Ferrero, D. Redondo; Sastre, J.; Ero, J.; Wulz, C.; Flouris, G.; Foudas, C.; Loukas, N.; Mallios, S.; Paradas, E.; Guiducci, L.; Masetti, G.

    2017-01-01

    The increase of luminosity expected by LHC during Phase1 will impose tighter constraints for rate reduction in order to maintain high efficiency in the CMS Level1 trigger system. The TwinMux system is the early layer of the muon barrel region that concentrates the information from different subdetectors: Drift Tubes, Resistive Plate Chambers and Outer Hadron Calorimeter. It arranges the slow optical trigger links from the detector chambers into faster links (10 Gbps) that are sent in multiple copies to the track finders. Results from collision runs, that confirm the satisfactory operation of the trigger system up to the output of the barrel track finder, will be shown.

  6. Event-triggered attitude control of spacecraft

    Science.gov (United States)

    Wu, Baolin; Shen, Qiang; Cao, Xibin

    2018-02-01

    The problem of spacecraft attitude stabilization control system with limited communication and external disturbances is investigated based on an event-triggered control scheme. In the proposed scheme, information of attitude and control torque only need to be transmitted at some discrete triggered times when a defined measurement error exceeds a state-dependent threshold. The proposed control scheme not only guarantees that spacecraft attitude control errors converge toward a small invariant set containing the origin, but also ensures that there is no accumulation of triggering instants. The performance of the proposed control scheme is demonstrated through numerical simulation.

  7. Electronic trigger for the ASP experiment

    International Nuclear Information System (INIS)

    Wilson, R.J.

    1985-11-01

    The Anomalous Single Photon (ASP) electronic trigger is described. The experiments is based on an electromagnetic calorimeter composed of arrays of lead glass blocks, read out with photo-multiplier tubes, surrounding the interaction point at the PEP storage ring. The primary requirement of the trigger system is to be sensitive to low energy (approx. =0.5 GeV and above) photons whilst discriminating against high backgrounds at PEP. Analogue summing of the PMT signals and a sequence of programmable digital look-up tables produces a ''dead-timeless'' trigger for the beam collision rate of 408 kHz. 6 refs., 6 figs

  8. The LHCb trigger in Run II

    CERN Document Server

    Michielin, Emanuele

    2016-01-01

    The LHCb trigger system has been upgraded to allow alignment, calibration and physics analysis to be performed in real time. An increased CPU capacity and improvements in the software have allowed lifetime unbiased selections of beauty and charm decays in the high level trigger. Thanks to offline quality event reconstruction already available online, physics analyses can be performed directly on this information and for the majority of charm physics selections a reduced event format can be written out. Beauty hadron decays are more efficiently triggered by re-optimised inclusive selections, and the HLT2 output event rate is increased by a factor of three.

  9. The Trigger Processor and Trigger Processor Algorithms for the ATLAS New Small Wheel Upgrade

    CERN Document Server

    Lazovich, Tomo; The ATLAS collaboration

    2015-01-01

    The ATLAS New Small Wheel (NSW) is an upgrade to the ATLAS muon endcap detectors that will be installed during the next long shutdown of the LHC. Comprising both MicroMegas (MMs) and small-strip Thin Gap Chambers (sTGCs), this system will drastically improve the performance of the muon system in a high cavern background environment. The NSW trigger, in particular, will significantly reduce the rate of fake triggers coming from track segments in the endcap not originating from the interaction point. We will present an overview of the trigger, the proposed sTGC and MM trigger algorithms, and the hardware implementation of the trigger. In particular, we will discuss both the heart of the trigger, an ATCA system with FPGA-based trigger processors (using the same hardware platform for both MM and sTGC triggers), as well as the full trigger electronics chain, including dedicated cards for transmission of data via GBT optical links. Finally, we will detail the challenges of ensuring that the trigger electronics can ...

  10. Triggered creep as a possible mechanism for delayed dynamic triggering of tremor and earthquakes

    Science.gov (United States)

    Shelly, David R.; Peng, Zhigang; Hill, David P.; Aiken, Chastity

    2011-01-01

    The passage of radiating seismic waves generates transient stresses in the Earth's crust that can trigger slip on faults far away from the original earthquake source. The triggered fault slip is detectable in the form of earthquakes and seismic tremor. However, the significance of these triggered events remains controversial, in part because they often occur with some delay, long after the triggering stress has passed. Here we scrutinize the location and timing of tremor on the San Andreas fault between 2001 and 2010 in relation to distant earthquakes. We observe tremor on the San Andreas fault that is initiated by passing seismic waves, yet migrates along the fault at a much slower velocity than the radiating seismic waves. We suggest that the migrating tremor records triggered slow slip of the San Andreas fault as a propagating creep event. We find that the triggered tremor and fault creep can be initiated by distant earthquakes as small as magnitude 5.4 and can persist for several days after the seismic waves have passed. Our observations of prolonged tremor activity provide a clear example of the delayed dynamic triggering of seismic events. Fault creep has been shown to trigger earthquakes, and we therefore suggest that the dynamic triggering of prolonged fault creep could provide a mechanism for the delayed triggering of earthquakes. ?? 2011 Macmillan Publishers Limited. All rights reserved.

  11. The second level trigger system of FAST

    CERN Document Server

    Martínez,G; Berdugo, J; Casaus, J; Casella, V; De Laere, D; Deiters, K; Dick, P; Kirkby, J; Malgeri, L; Mañá, C; Marín, J; Pohl, M; Petitjean, C; Sánchez, E; Willmott, C

    2009-01-01

    The Fibre Active Scintillator Target (FAST) experiment is a novel imaging particle detector currently operating in a high-intensity π+ beam at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The detector is designed to perform a high precision measurement of the μ+ lifetime, in order to determine the Fermi constant, Gf, to 1 ppm precision. A dedicated second level (LV2) hardware trigger system has been developed for the experiment. It performs an online analysis of the π/μ decay chain by identifying the stopping position of each beam particle and detecting the subsequent appearance of the muon. The LV2 trigger then records the muon stop pixel and selectively triggers the Time-to-Digital Converters (TDCs) in the vicinity. A detailed description of the trigger system is presented in this paper.

  12. The second level trigger system of FAST

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, G. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)], E-mail: gustavo.martinez@ciemat.es; Barcyzk, A. [CERN, CH-1211 Geneva 23 (Switzerland); Berdugo, J.; Casaus, J. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Casella, C.; De Laere, S. [Universite de Geneve, 30 quai Ernest-Anserment, CH-1211 Geneva 4 (Switzerland); Deiters, K.; Dick, P. [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Kirkby, J.; Malgeri, L. [CERN, CH-1211 Geneva 23 (Switzerland); Mana, C.; Marin, J. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain); Pohl, M. [Universite de Geneve, 30 quai Ernest-Anserment, CH-1211 Geneva 4 (Switzerland); Petitjean, C. [Paul Scherrer Institut, 5232 Villigen PSI (Switzerland); Sanchez, E.; Willmott, C. [CIEMAT, Avenida Complutense 22, 28040 Madrid (Spain)

    2009-10-11

    The Fibre Active Scintillator Target (FAST) experiment is a novel imaging particle detector currently operating in a high-intensity {pi}{sup +} beam at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The detector is designed to perform a high precision measurement of the {mu}{sup +} lifetime, in order to determine the Fermi constant, G{sub f}, to 1 ppm precision. A dedicated second level (LV2) hardware trigger system has been developed for the experiment. It performs an online analysis of the {pi}/{mu} decay chain by identifying the stopping position of each beam particle and detecting the subsequent appearance of the muon. The LV2 trigger then records the muon stop pixel and selectively triggers the Time-to-Digital Converters (TDCs) in the vicinity. A detailed description of the trigger system is presented in this paper.

  13. SSC physics signatures and trigger requirements

    International Nuclear Information System (INIS)

    1985-01-01

    Strategies are considered for triggering on new physics processes on the environment of the SSC, where interaction rates will be very high and most new physics processes quite rare. The quantities available for use in the trigger at various levels are related to the signatures of possible new physics. Two examples were investigated in some detail using the ISAJET Monte Carlo program: Higgs decays to W pairs and a missing energy trigger applied to gluino pair production. In both of the examples studied in detail, it was found that workable strategies for reducing the trigger rate were obtainable which also produced acceptable efficiency for the processes of interest. In future work, it will be necessary to carry out such a program for the full spectrum of suggested new physics

  14. Graphics Processing Units for HEP trigger systems

    International Nuclear Information System (INIS)

    Ammendola, R.; Bauce, M.; Biagioni, A.; Chiozzi, S.; Cotta Ramusino, A.; Fantechi, R.; Fiorini, M.; Giagu, S.; Gianoli, A.; Lamanna, G.; Lonardo, A.; Messina, A.

    2016-01-01

    General-purpose computing on GPUs (Graphics Processing Units) is emerging as a new paradigm in several fields of science, although so far applications have been tailored to the specific strengths of such devices as accelerator in offline computation. With the steady reduction of GPU latencies, and the increase in link and memory throughput, the use of such devices for real-time applications in high-energy physics data acquisition and trigger systems is becoming ripe. We will discuss the use of online parallel computing on GPU for synchronous low level trigger, focusing on CERN NA62 experiment trigger system. The use of GPU in higher level trigger system is also briefly considered.

  15. Pulling the trigger on LHC electronics

    CERN Document Server

    CERN. Geneva

    2001-01-01

    The conditions at CERN's Large Hadron Collider pose severe challenges for the designers and builders of front-end, trigger and data acquisition electronics. A recent workshop reviewed the encouraging progress so far and discussed what remains to be done. The LHC experiments have addressed level one trigger systems with a variety of high-speed hardware. The CMS Calorimeter Level One Regional Trigger uses 160 MHz logic boards plugged into the front and back of a custom backplane, which provides point-to-point links between the cards. Much of the processing in this system is performed by five types of 160 MHz digital applications-specific integrated circuits designed using Vitesse submicron high-integration gallium arsenide gate array technology. The LHC experiments make extensive use of field programmable gate arrays (FPGAs). These offer programmable reconfigurable logic, which has the flexibility that trigger designers need to be able to alter algorithms so that they can follow the physics and detector perform...

  16. Boredom and Passion: Triggers of Habitual Entrepreneurship

    DEFF Research Database (Denmark)

    Müller, Sabine; Neergaard, Helle

    . The case based, the study identifies eight factors, which contribute to consecutive venture creation. The findings suggest that boredom and passion are necessary conditions triggering habitual entrepreneurship. Other important mechanisms included the joy of discovering and exploiting an opportunity...

  17. D0 triggering and data acquisition

    International Nuclear Information System (INIS)

    Gibbard, B.

    1992-10-01

    The trigger for D0 is a multi-tier system. Within the 3.5 μsec bunch crossing interval, custom electronics select interesting event candidates based on electromagnetic and hadronic energy deposits in the calorimeter and on indications of tracks in the muon system. Subsequent hardware decisions use refined calculations of electron and muon characteristics. The highest level trigger occurs in one element of a farm of microprocessors, where fully developed algorithms for electrons, muons, jets, or missing E t are executed. This highest level trigger also provides the assembly of the event into its final data structure. Performance of this trigger and data acquisition system in collider operation is described

  18. Triggering and data acquisition general considerations

    International Nuclear Information System (INIS)

    Butler, Joel N.

    2003-01-01

    We provide a general introduction to trigger and data acquisition systems in High Energy Physics. We emphasize the new possibilities and new approaches that have been made possible by developments in computer technology and networking

  19. Session summary: Electronics, triggering and data acquisition

    International Nuclear Information System (INIS)

    Rescia, S.

    1991-12-01

    The session focused on the requirements for calorimetry at the SSC/LHC. Results on new readout techniques, calibration, radiation hard electronics and semiconductor devices, analog and digital front and electronics, and trigger strategies are presented

  20. Trigger factors in migraine with aura

    DEFF Research Database (Denmark)

    Hauge, A W; Kirchmann, M; Olesen, J

    2010-01-01

    The aim of the present study was to identify trigger factors in migraine with aura (MA). A total of 629 MA patients representative of the Danish population were sent a questionnaire listing 16 trigger factors thought to be relevant as well as space for free text. Distinction was made between...... attacks with or without aura within each patient. The questionnaire was returned by 522 patients of whom 347 had current MA attacks. In total 80% with current attacks (278/347) indicated that at least one factor triggered their migraine, and 67% (187/278) in this group indicated that they were aware...... of at least one factor often or always giving rise to an attack of MA. Forty-one per cent (113/278) had co-occurring attacks of migraine without aura (MO). Stress (following stress), bright light, intense emotional influences, stress (during stress) and sleeping too much or too little were the trigger factors...

  1. The Aurora accelerator's triggered oil switch

    International Nuclear Information System (INIS)

    Weidenheimer, D.M.; Pereira, N.R.; Judy, D.C.; Stricklett, K.L.

    1993-01-01

    Achieving a radiation pulse with 15 ns risetime using all four of the Aurora accelerator's Blumlein pulse-forming lines demands synchronization of the Blumleins to within 10 ns (in addition to a 15 ns risetime for a single line). Timing of each Blumlein is controlled by a triggered 12 MV oil switch. A smaller-than-customary trigger electrode makes the switching time more reproducible. Time-resolved photography of the oil arcs suggests that triggering occurs simultaneously around the sharp edge of the trigger electrode, perhaps with small deviations that grow into the most prominent arcs characteristically seen in open-shutter photographs. However, many smaller arcs that are usually overlooked in open-shutter pictures may contribute to current conduction in a closed switch

  2. Graphics Processing Units for HEP trigger systems

    Energy Technology Data Exchange (ETDEWEB)

    Ammendola, R. [INFN Sezione di Roma “Tor Vergata”, Via della Ricerca Scientifica 1, 00133 Roma (Italy); Bauce, M. [INFN Sezione di Roma “La Sapienza”, P.le A. Moro 2, 00185 Roma (Italy); University of Rome “La Sapienza”, P.lee A.Moro 2, 00185 Roma (Italy); Biagioni, A. [INFN Sezione di Roma “La Sapienza”, P.le A. Moro 2, 00185 Roma (Italy); Chiozzi, S.; Cotta Ramusino, A. [INFN Sezione di Ferrara, Via Saragat 1, 44122 Ferrara (Italy); University of Ferrara, Via Saragat 1, 44122 Ferrara (Italy); Fantechi, R. [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); CERN, Geneve (Switzerland); Fiorini, M. [INFN Sezione di Ferrara, Via Saragat 1, 44122 Ferrara (Italy); University of Ferrara, Via Saragat 1, 44122 Ferrara (Italy); Giagu, S. [INFN Sezione di Roma “La Sapienza”, P.le A. Moro 2, 00185 Roma (Italy); University of Rome “La Sapienza”, P.lee A.Moro 2, 00185 Roma (Italy); Gianoli, A. [INFN Sezione di Ferrara, Via Saragat 1, 44122 Ferrara (Italy); University of Ferrara, Via Saragat 1, 44122 Ferrara (Italy); Lamanna, G., E-mail: gianluca.lamanna@cern.ch [INFN Sezione di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); INFN Laboratori Nazionali di Frascati, Via Enrico Fermi 40, 00044 Frascati (Roma) (Italy); Lonardo, A. [INFN Sezione di Roma “La Sapienza”, P.le A. Moro 2, 00185 Roma (Italy); Messina, A. [INFN Sezione di Roma “La Sapienza”, P.le A. Moro 2, 00185 Roma (Italy); University of Rome “La Sapienza”, P.lee A.Moro 2, 00185 Roma (Italy); and others

    2016-07-11

    General-purpose computing on GPUs (Graphics Processing Units) is emerging as a new paradigm in several fields of science, although so far applications have been tailored to the specific strengths of such devices as accelerator in offline computation. With the steady reduction of GPU latencies, and the increase in link and memory throughput, the use of such devices for real-time applications in high-energy physics data acquisition and trigger systems is becoming ripe. We will discuss the use of online parallel computing on GPU for synchronous low level trigger, focusing on CERN NA62 experiment trigger system. The use of GPU in higher level trigger system is also briefly considered.

  3. Trigger circuits for the PHENIX electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Frank, S.S.; Britton, C.L. Jr.; Winterberg, A.L.; Young, G.R.

    1997-11-01

    Monolithic and discrete circuits have been developed to provide trigger signals for the PHENIX electromagnetic calorimeter detector. These trigger circuits are deadtimeless and create overlapping 4 by 4 energy sums, a cosmic muon trigger, and a 144 channel energy sum. The front end electronics of the PHENIX system sample the energy and timing channels at each bunch crossing (BC) but it is not known immediately if this data is of interest. The information from the trigger circuits is used to determine if the data collected is of interest and should be digitized and stored or discarded. This paper presents details of the design, issues affecting circuit performance, characterization of prototypes fabricated in 1.2 microm Orbit CMOS, and integration of the circuits into the EMCal electronics system

  4. New Fast Interaction Trigger for ALICE

    Energy Technology Data Exchange (ETDEWEB)

    Trzaska, Wladyslaw Henryk

    2017-02-11

    The LHC heavy-ion luminosity and collision rate from 2021 onwards will considerably exceed the design parameters of the present ALICE forward trigger detectors and the introduction of the Muon Forward Tracker (MFT) will significantly reduce the space available for the new trigger detectors. To comply with these conditions a new Fast Interaction Trigger (FIT) will be built. FIT will be the main forward trigger, luminometer, and interaction-time detector. It will also determine multiplicity, centrality, and reaction plane of heavy-ion collisions. FIT will consist of two arrays of Cherenkov quartz radiators with MCP-PMT sensors and of a plastic scintillator ring. By increasing the overall acceptance of FIT, the scintillator will improve centrality and event plane resolution. It will also add sensitivity for the detection of beam-gas events and provide some degree of redundancy. FIT is currently undergoing an intense R&D and prototyping period. It is scheduled for installation in ALICE during 2020.

  5. The new UA1 calorimeter trigger

    International Nuclear Information System (INIS)

    Eisenhandler, E.

    1988-01-01

    The new UA1 first-level calorimeter trigger processor is described, with emphasis on the fast two-dimensional electromagnetic cluster-finding that is its most novel feature. This processor is about five times more powerful than its predecessor, and makes extensive use of pipelining techniques. It allows multiple combinations of triggers on electromagnetic showers, hadronic jets and energy sums, including a total-energy veto of multiple interactions and a full vector sum of missing transverse energy. (author)

  6. The upgrade of the LHCb trigger system

    CERN Document Server

    INSPIRE-00259834; Fitzpatrick, C.; Gligorov, V.; Raven, G.

    2014-10-20

    The LHCb experiment will operate at a luminosity of $2\\times10^{33}$ cm$^{-2}$s$^{-1}$ during LHC Run 3. At this rate the present readout and hardware Level-0 trigger become a limitation, especially for fully hadronic final states. In order to maintain a high signal efficiency the upgraded LHCb detector will deploy two novel concepts: a triggerless readout and a full software trigger.

  7. EMIC triggered chorus emissions in Cluster data

    Science.gov (United States)

    Grison, B.; SantolíK, O.; Cornilleau-Wehrlin, N.; Masson, A.; Engebretson, M. J.; Pickett, J. S.; Omura, Y.; Robert, P.; Nomura, R.

    2013-03-01

    Electromagnetic ion cyclotron (EMIC) triggered chorus emissions have recently been a subject of several experimental, theoretical and simulation case studies, noting their similarities with whistler-mode chorus. We perform a survey of 8 years of Cluster data in order to increase the database of EMIC triggered emissions. The results of this is that EMIC triggered emissions have been unambiguously observed for only three different days. These three events are studied in detail. All cases have been observed at the plasmapause between 22 and 24 magnetic local time (MLT) and between - 15° and 15° magnetic latitude (λm). Triggered emissions are also observed for the first time below the local He+ gyrofrequency (fHe+). The number of events is too low to produce statistical results, nevertheless we point out a variety of common properties of those waves. The rising tones have a high level of coherence and the waves propagate away from the equatorial region. The propagation angle and degree of polarization are related to the distance from the equator, whereas the slope and the frequency extent vary from one event to the other. From the various spacecraft separations, we determine that the triggering process is a localized phenomenon in space and time. However, we are unable to determine the occurrence rates of these waves. Small frequency extent rising tones are more common than large ones. The newly reported EMIC triggered events are generally observed during periods of large AE index values and in time periods close to solar maximum.

  8. Progress on the Level-1 Calorimeter Trigger

    CERN Multimedia

    Eric Eisenhandler

    The Level-1 Calorimeter Trigger (L1Calo) has recently passed a number of major hurdles. The various electronic modules that make up the trigger are either in full production or are about to be, and preparations in the ATLAS pit are well advanced. L1Calo has three main subsystems. The PreProcessor converts analogue calorimeter signals to digital, associates the rather broad trigger pulses with the correct proton-proton bunch crossing, and does a final calibration in transverse energy before sending digital data streams to the two algorithmic trigger processors. The Cluster Processor identifies and counts electrons, photons and taus, and the Jet/Energy-sum Processor looks for jets and also sums missing and total transverse energy. Readout drivers allow the performance of the trigger to be monitored online and offline, and also send region-of-interest information to the Level-2 Trigger. The PreProcessor (Heidelberg) is the L1Calo subsystem with the largest number of electronic modules (124), and most of its fu...

  9. Triggered tremor sweet spots in Alaska

    Science.gov (United States)

    Gomberg, Joan; Prejean, Stephanie

    2013-01-01

    To better understand what controls fault slip along plate boundaries, we have exploited the abundance of seismic and geodetic data available from the richly varied tectonic environments composing Alaska. A search for tremor triggered by 11 large earthquakes throughout all of seismically monitored Alaska reveals two tremor “sweet spots”—regions where large-amplitude seismic waves repeatedly triggered tremor between 2006 and 2012. The two sweet spots locate in very different tectonic environments—one just trenchward and between the Aleutian islands of Unalaska and Akutan and the other in central mainland Alaska. The Unalaska/Akutan spot corroborates previous evidence that the region is ripe for tremor, perhaps because it is located where plate-interface frictional properties transition between stick-slip and stably sliding in both the dip direction and laterally. The mainland sweet spot coincides with a region of complex and uncertain plate interactions, and where no slow slip events or major crustal faults have been noted previously. Analyses showed that larger triggering wave amplitudes, and perhaps lower frequencies (tremor. However, neither the maximum amplitude in the time domain or in a particular frequency band, nor the geometric relationship of the wavefield to the tremor source faults alone ensures a high probability of triggering. Triggered tremor at the two sweet spots also does not occur during slow slip events visually detectable in GPS data, although slow slip below the detection threshold may have facilitated tremor triggering.

  10. Hierarchical trigger of the ALICE calorimeters

    CERN Document Server

    Muller, Hans; Novitzky, Norbert; Kral, Jiri; Rak, Jan; Schambach, Joachim; Wang, Ya-Ping; Wang, Dong; Zhou, Daicui

    2010-01-01

    The trigger of the ALICE electromagnetic calorimeters is implemented in 2 hierarchically connected layers of electronics. In the lower layer, level-0 algorithms search shower energy above threshold in locally confined Trigger Region Units (TRU). The top layer is implemented as a single, global trigger unit that receives the trigger data from all TRUs as input to the level-1 algorithm. This architecture was first developed for the PHOS high pT photon trigger before it was adopted by EMCal also for the jet trigger. TRU units digitize up to 112 analogue input signals from the Front End Electronics (FEE) and concentrate their digital stream in a single FPGA. A charge and time summing algorithm is combined with a peakfinder that suppresses spurious noise and is precise to single LHC bunches. With a peak-to-peak noise level of 150 MeV the linear dynamic range above threshold spans from MIP energies at 215 up to 50 GeV. Local level-0 decisions take less than 600 ns after LHC collisions, upon which all TRUs transfer ...

  11. Level-1 Calorimeter Trigger starts firing

    CERN Multimedia

    Stephen Hillier

    2007-01-01

    L1Calo is one of the major components of ATLAS First Level trigger, along with the Muon Trigger and Central Trigger Processor. It forms all of the first-level calorimeter-based triggers, including electron, jet, tau and missing ET. The final system consists of over 250 custom designed 9U VME boards, most containing a dense array of FPGAs or ASICs. It is subdivided into a PreProcessor, which digitises the incoming trigger signals from the Liquid Argon and Tile calorimeters, and two separate processor systems, which perform the physics algorithms. All of these are highly flexible, allowing the possibility to adapt to beam conditions and luminosity. All parts of the system are read out through Read-Out Drivers, which provide monitoring data and Region of Interest (RoI) information for the Level-2 trigger. Production of the modules is now essentially complete, and enough modules exist to populate the full scale system in USA15. Installation is proceeding rapidly - approximately 90% of the final modules are insta...

  12. The LHCb trigger and data acquisition system

    CERN Document Server

    Dufey, J P; Harris, F; Harvey, J; Jost, B; Mato, P; Müller, E

    2000-01-01

    The LHCb experiment is the most recently approved of the 4 experiments under construction at CERNs LHC accelerator. It is a special purpose experiment designed to precisely measure the CP violation parameters in the B-B system. Triggering poses special problems since the interesting events containing B-mesons are immersed in a large background of inelastic p-p reactions. We therefore decided to implement a 4 level triggering scheme. The LHCb Data Acquisition (DAQ) system will have to cope with an average trigger rate of ~40 kHz, after two levels of hardware triggers, and an average event size of ~100 kB. Thus an event-building network which can sustain an average bandwidth of 4 GB/s is required. A powerful software trigger farm will have to be installed to reduce the rate from the 40 kHz to ~100 Hz of events written to permanent storage. In this paper we outline the general architecture of the Trigger and DAQ system and the readout protocols we plan to implement. First results of simulations of the behavior o...

  13. Oriental upper blepharoplasty.

    Science.gov (United States)

    Weng, Chau-Jin

    2009-02-01

    Aesthetic surgery of the upper eyelids is a very common procedure performed in cosmetic practices around the world. The word blepharoplasty, however, has a different meaning in Asia than it does elsewhere. Orientals have different periorbital anatomic characteristics, their motivations for seeking eyelid treatment are different, and operative techniques have been adapted consequently. There are also many eyelid shapes among Orientals, mostly with regard to the presence and location of the supratarsal fold and/or presence of an epicanthal fold. The surgeon must therefore master a range of surgical procedures to treat these variations adequately. It is critical to know the indications for each blepharoplasty technique as well as their complications to select the right surgery and avoid unfavorable results. Epicanthoplasty performed on the right patient can greatly improve aesthetic results while retaining ethnic characteristics. This article will discuss Oriental eyelid characteristics, preoperative patient assessment, commonly used corrective techniques for the "double-eyelid" creation, and complications and how to avoid them.

  14. Design studies for the Double Chooz trigger

    International Nuclear Information System (INIS)

    Cucoanes, Andi Sebastian

    2009-01-01

    The main characteristic of the neutrino mixing effect is assumed to be the coupling between the flavor and the mass eigenstates. Three mixing angles (θ 12 , θ 23 , θ 13 ) are describing the magnitude of this effect. Still unknown, θ 13 is considered very small, based on the measurement done by the CHOOZ experiment. A leading experiment will be Double Chooz, placed in the Ardennes region, on the same site as used by CHOOZ. The Double Chooz goal is the exploration of ∝80% from the currently allowed θ 13 region, by searching the disappearance of reactor antineutrinos. Double Chooz will use two similar detectors, located at different distances from the reactor cores: a near one at ∝150 m where no oscillations are expected and a far one at 1.05 km distance, close to the first minimum of the survival probability function. The measurement foresees a precise comparison of neutrino rates and spectra between both detectors. The detection mechanism is based on the inverse β-decay. The Double Chooz detectors have been designed to minimize the rate of random background. In a simplified view, two optically separated regions are considered. The target, filled with Gd-doped liquid scintillator, is the main antineutrino interaction volume. Surrounding the target, the inner veto region aims to tag the cosmogenic muon background which hits the detector. Both regions are viewed by photomultipliers. The Double Chooz trigger system has to be highly efficient for antineutrino events as well as for several types of background. The trigger analyzes discriminated signals from the central region and the inner veto photomultipliers. The trigger logic is fully programmable and can combine the input signals. The trigger conditions are based on the total energy released in event and on the PMT groups multiplicity. For redundancy, two independent trigger boards will be used for the central region, each of them receiving signals from half of the photomultipliers. A third trigger board

  15. Design studies for the Double Chooz trigger

    Energy Technology Data Exchange (ETDEWEB)

    Cucoanes, Andi Sebastian

    2009-07-24

    The main characteristic of the neutrino mixing effect is assumed to be the coupling between the flavor and the mass eigenstates. Three mixing angles ({theta}{sub 12}, {theta}{sub 23}, {theta}{sub 13}) are describing the magnitude of this effect. Still unknown, {theta}{sub 13} is considered very small, based on the measurement done by the CHOOZ experiment. A leading experiment will be Double Chooz, placed in the Ardennes region, on the same site as used by CHOOZ. The Double Chooz goal is the exploration of {proportional_to}80% from the currently allowed {theta}{sub 13} region, by searching the disappearance of reactor antineutrinos. Double Chooz will use two similar detectors, located at different distances from the reactor cores: a near one at {proportional_to}150 m where no oscillations are expected and a far one at 1.05 km distance, close to the first minimum of the survival probability function. The measurement foresees a precise comparison of neutrino rates and spectra between both detectors. The detection mechanism is based on the inverse {beta}-decay. The Double Chooz detectors have been designed to minimize the rate of random background. In a simplified view, two optically separated regions are considered. The target, filled with Gd-doped liquid scintillator, is the main antineutrino interaction volume. Surrounding the target, the inner veto region aims to tag the cosmogenic muon background which hits the detector. Both regions are viewed by photomultipliers. The Double Chooz trigger system has to be highly efficient for antineutrino events as well as for several types of background. The trigger analyzes discriminated signals from the central region and the inner veto photomultipliers. The trigger logic is fully programmable and can combine the input signals. The trigger conditions are based on the total energy released in event and on the PMT groups multiplicity. For redundancy, two independent trigger boards will be used for the central region, each of

  16. Retrospective respiratory triggering renal perfusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, Ulrike I.; Michaely, Henrik J.; Schoenberg, Stefan O. (Dept. of Clinical Radiology and Nuclear Medicine, Univ. Hospital Mannheim, Univ. of Heidelberg, Mannheim (Germany)), e-mail: ulrike.attenberger@medma.uni-heidelberg.de; Sourbron, Steven P. (Div. of Medical Physics, Univ. of Leeds, Leeds (United Kingdom)); Reiser, Maximilian F. (Dept. of Clinical Radiology, Univ. Hospitals Munich, Grosshadern, Ludwig-Maximilians-Univ., Munich (Germany))

    2010-12-15

    Background: Artifacts of respiratory motion are one of the well-known limitations of dynamic contrast-enhanced MRI (DCE-MRI) of the kidney. Purpose: To propose and evaluate a retrospective triggering approach to minimize the effect of respiratory motion in DCE-MRI of the kidney. Material and Methods: Nine consecutive patients underwent renal perfusion measurements. Data were acquired with a 2D saturation-recovery TurboFLASH sequence. In order to test the dependence of the results on size and location of the manually drawn triggering regions of interest (ROIs), three widely differing triggering regions were defined by one observer. Mean value, standard deviation, and variability of the renal function parameters plasma flow (FP), plasma volume (VP), plasma transit time (TP), tubular flow (FT), tubular volume (VT), and tubular transit time (TT) were calculated on a per-patient basis. Results: The results show that triggered data have adequate temporal resolution to measure blood flow. The overall average values of the function parameters were: 152.77 (FP), 15.18 (VP), 6,73 (TP), 18.50 (FT), 35.36 (VT), and 117.67 (TT). The variability (calculated in % SD from the mean value) for three different respiratory triggering regions defined on a per-patient basis was between 0.81% and 9.87% for FP, 1.45% and 8.19% for VP, 0% and 9.63% for TP, 2.15% and 12.23% for TF, 0.8% and 17.28% for VT, and 1.97% and 12.87% for TT. Conclusion: Triggering reduces the oscillations in the signal curves and produces sharper parametric maps. In contrast to numerically challenging approaches like registration and segmentation it can be applied in clinical routine, but a (semi)-automatic approach to select the triggering ROI is desirable to reduce user dependence.

  17. Aftershocks and triggering processes in rock fracture

    Science.gov (United States)

    Davidsen, J.; Kwiatek, G.; Goebel, T.; Stanchits, S. A.; Dresen, G.

    2017-12-01

    One of the hallmarks of our understanding of seismicity in nature is the importance of triggering processes, which makes the forecasting of seismic activity feasible. These triggering processes by which one earthquake induces (dynamic or static) stress changes leading to potentially multiple other earthquakes are at the core relaxation processes. A specic example of triggering are aftershocks following a large earthquake, which have been observed to follow certain empirical relationships such as the Omori-Utsu relation. Such an empirical relation should arise from the underlying microscopic dynamics of the involved physical processes but the exact connection remains to be established. Simple explanations have been proposed but their general applicability is unclear. Many explanations involve the picture of an earthquake as a purely frictional sliding event. Here, we present experimental evidence that these empirical relationships are not limited to frictional processes but also arise in fracture zone formation and are mostly related to compaction-type events. Our analysis is based on tri-axial compression experiments under constant displacement rate on sandstone and granite samples using spatially located acoustic emission events and their focal mechanisms. More importantly, we show that event-event triggering plays an important role in the presence of large-scale or macrocopic imperfections while such triggering is basically absent if no signicant imperfections are present. We also show that spatial localization and an increase in activity rates close to failure do not necessarily imply triggering behavior associated with aftershocks. Only if a macroscopic crack is formed and its propagation remains subcritical do we observe significant triggering.

  18. Rate Predictions and Trigger/DAQ Resource Monitoring in ATLAS

    CERN Document Server

    Schaefer, D M; The ATLAS collaboration

    2012-01-01

    Since starting in 2010, the Large Hadron Collider (LHC) has pro- duced collisions at an ever increasing rate. The ATLAS experiment successfully records the collision data with high eciency and excel- lent data quality. Events are selected using a three-level trigger system, where each level makes a more re ned selection. The level-1 trigger (L1) consists of a custom-designed hardware trigger which seeds two higher software based trigger levels. Over 300 triggers compose a trig- ger menu which selects physics signatures such as electrons, muons, particle jets, etc. Each trigger consumes computing resources of the ATLAS trigger system and oine storage. The LHC instantaneous luminosity conditions, desired physics goals of the collaboration, and the limits of the trigger infrastructure determine the composition of the ATLAS trigger menu. We describe a trigger monitoring frame- work for computing the costs of individual trigger algorithms such as data request rates and CPU consumption. This framework has been used...

  19. Upgrades of the ATLAS trigger system

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00221618; The ATLAS collaboration

    2018-01-01

    In coming years the LHC is expected to undergo upgrades to increase both the energy of proton-proton collisions and the instantaneous luminosity. In order to cope with these more challenging LHC conditions, upgrades of the ATLAS trigger system will be required. This talk will focus on some of the key aspects of these upgrades. Firstly, the upgrade period between 2019-2021 will see an increase in instantaneous luminosity to $3\\times10^{34} \\rm{cm^{-2}s^{-1}}$. Upgrades to the Level 1 trigger system during this time will include improvements for both the muon and calorimeter triggers. These include the upgrade of the first-level Endcap Muon trigger, the calorimeter trigger electronics and the addition of new calorimeter feature extractor hardware, such as the Global Feature Extractor (gFEX). An overview will be given on the design and development status the aforementioned systems, along with the latest testing and validation results. \\\\ By 2026, the High Luminosity LHC will be able to deliver 14 TeV collisions ...

  20. Graphical processors for HEP trigger systems

    International Nuclear Information System (INIS)

    Ammendola, R.; Biagioni, A.; Chiozzi, S.; Cotta Ramusino, A.; Di Lorenzo, S.; Fantechi, R.; Fiorini, M.; Frezza, O.; Lamanna, G.; Lo Cicero, F.; Lonardo, A.; Martinelli, M.; Neri, I.; Paolucci, P.S.; Pastorelli, E.; Piandani, R.; Pontisso, L.; Rossetti, D.; Simula, F.; Sozzi, M.

    2017-01-01

    General-purpose computing on GPUs is emerging as a new paradigm in several fields of science, although so far applications have been tailored to employ GPUs as accelerators in offline computations. With the steady decrease of GPU latencies and the increase in link and memory throughputs, time is ripe for real-time applications using GPUs in high-energy physics data acquisition and trigger systems. We will discuss the use of online parallel computing on GPUs for synchronous low level trigger systems, focusing on tests performed on the trigger of the CERN NA62 experiment. Latencies of all components need analysing, networking being the most critical. To keep it under control, we envisioned NaNet, an FPGA-based PCIe Network Interface Card (NIC) enabling GPUDirect connection. Moreover, we discuss how specific trigger algorithms can be parallelised and thus benefit from a GPU implementation, in terms of increased execution speed. Such improvements are particularly relevant for the foreseen LHC luminosity upgrade where highly selective algorithms will be crucial to maintain sustainable trigger rates with very high pileup.

  1. CMS Triggers for the LHC Startup

    CERN Document Server

    Nhan Nguyen, Chi

    2009-01-01

    The LHC will collide proton beams at a bunch-crossing rate of 40 MHz. At the design luminosity of $10^{34}$ cm$^{-2}$s$^{-1}$ each crossing results in an average of about 20 inelastic pp events. The CMS trigger system is designed to reduce the input rate to about 100 Hz. This task is carried out in two steps, namely the Level-1 (L1) and the High-Level trigger (HLT). The L1 trigger is built of customized fast electronics and is designed to reduce the rate to 100 kHz. The HLT is implemented in a filter farm running on hundreds of CPUs and is designed to reduce the rate by another factor of ~1000. It combines the traditional L2 and L3 trigger components in a novel way and allows the coherent tuning of the HLT algorithms to accommodate multiple physics channels. We will discuss the strategies for optimizing triggers covering the experiment`s early physics program.

  2. The Fast Interaction Trigger Upgrade for ALICE

    CERN Document Server

    Garcia-Solis, Edmundo

    2016-01-01

    The ALICE Collaboration is preparing a major detector upgrade for the second LHC long shutdown (2019–20). The LHC heavy-ion luminosity and collision rate from 2021 onwards will considerably exceed the design parameters of the present ALICE forward trigger detectors. Furthermore, the introduction of a new Muon Forward Tracker (MFT) will significantly reduce the space available for the upgraded trigger detectors. To comply with these conditions a Fast Interaction Trigger (FIT) has been designed. FIT will be the primary forward trigger, luminosity, and collision time measurement detector. The FIT will be capable of triggering at an interaction rate of 50 kHz, with a time resolution better than 30 ps, with 99% efficiency. It will also determine multiplicity, centrality, and reaction plane. FIT will consist of two arrays of Cherenkov radiators with MCP-PMT sensors and of a single, large-size scintillator ring. The arrays will be placed on both sides of the interaction point (IP). Because of the presence of the h...

  3. Tools for Trigger Rate Monitoring at CMS

    CERN Document Server

    Smith, Geoffrey; Wightman, Andrew Steven

    2017-01-01

    In 2017, we expect the LHC to deliver an instantaneous luminosity of roughly $2.0 \\times 10^{34}$~cm$^{-2}$s$^{-1}$ to the Compact Muon Solenoid (CMS) experiment, with about 60 simultaneous proton-proton collisions (pileup) per event. In these challenging conditions, it is important to be able to intelligently monitor the rate at which data are being collected (the trigger rate). It is not enough to simply look at the trigger rate; it is equally important to compare the trigger rate with expectations. We present a set of software tools that have been developed to accomplish this. The tools include a real-time component - a script that monitors the rates of individual triggers during data-taking, and activates an alarm if rates deviate significantly from expectation. Fits are made to previously collected data and extrapolated to higher pileup. The behavior of triggers as a function of pileup is then monitored as data are collected - plots are automatically produced on an hourly basis and uploaded to a web area...

  4. Tracking at High Level Trigger in CMS

    CERN Document Server

    Tosi, Mia

    2016-01-01

    The trigger systems of the LHC detectors play a crucial role in determining the physics capabili- ties of the experiments. A reduction of several orders of magnitude of the event rate is needed to reach values compatible with detector readout, offline storage and analysis capability. The CMS experiment has been designed with a two-level trigger system: the Level-1 Trigger (L1T), implemented on custom-designed electronics, and the High Level Trigger (HLT), a stream- lined version of the CMS offline reconstruction software running on a computer farm. A software trigger system requires a trade-off between the complexity of the algorithms, the sustainable out- put rate, and the selection efficiency. With the computing power available during the 2012 data taking the maximum reconstruction time at HLT was about 200 ms per event, at the nominal L1T rate of 100 kHz. Track reconstruction algorithms are widely used in the HLT, for the reconstruction of the physics objects as well as in the identification of b-jets and ...

  5. The D-Zero Run II Trigger

    International Nuclear Information System (INIS)

    Blazey, G. C.

    1997-01-01

    The general purpose D0 collider detector, located at Fermi National Accelerator Laboratory, requires significantly enhanced data acquisition and triggering to operate in the high luminosity (L = 2 x 10 32 cm -2 s -1 ), high rate environment (7 MHz or 132 ns beam crossings) of the upgraded TeVatron proton anti-proton accelerator. This article describes the three major levels and frameworks of the new trigger. Information from the first trigger stage (L1) which includes scintillating, tracking and calorimeter detectors will provide a deadtimeless, 4.2 (micro)s trigger decision with an accept rate of 10 kHz. The second stage (L2), comprised of hardware engines associated with specific detectors and a single global processor will test for correlations between L1 triggers. L2 will have an accept rate of 1 kHz at a maximum deadtime of 5% and require a 100 (micro)s decision time. The third and final stage (L3) will reconstruct events in a farm of processors for a final instantaneous accept rate of 50 Hz

  6. DZERO Level 3 DAQ/Trigger Closeout

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    The Tevatron Collider, located at the Fermi National Accelerator Laboratory, delivered its last 1.96 TeV proton-antiproton collisions on September 30th, 2011. The DZERO experiment continues to take cosmic data for final alignment for several more months . Since Run 2 started, in March 2001, all DZERO data has been collected by the DZERO Level 3 Trigger/DAQ System. The system is a modern, networked, commodity hardware trigger and data acquisition system based around a large central switch with about 60 front ends and 200 trigger computers. DZERO front end crates are VME based. Single Board Computer interfaces between detector data on VME and the network transport for the DAQ system. Event flow is controlled by the Routing Master which can steer events to clusters of farm nodes based on the low level trigger bits that fired. The farm nodes are multi-core commodity computer boxes, without special hardware, that run isolated software to make the final Level 3 trigger decision. Passed events are transferred to th...

  7. Graphical processors for HEP trigger systems

    Energy Technology Data Exchange (ETDEWEB)

    Ammendola, R. [INFN Sezione di Roma Tor Vergata, Via della Ricerca Scientifica, 1, 00133 Roma (Italy); Biagioni, A. [INFN Sezione di Roma, P.le Aldo Moro, 2, 00185 Roma (Italy); Chiozzi, S.; Cotta Ramusino, A. [INFN Sezione di Ferrara, Via Saragat, 1, 44122 Ferrara (Italy); Di Lorenzo, S. [INFN Sezione di Pisa, L. Bruno Pontecorvo, 3, 56127 Pisa (Italy); Università di Pisa, Lungarno Pacinotti 43, 56126 Pisa (Italy); Fantechi, R. [INFN Sezione di Pisa, L. Bruno Pontecorvo, 3, 56127 Pisa (Italy); Fiorini, M. [INFN Sezione di Ferrara, Via Saragat, 1, 44122 Ferrara (Italy); Università di Ferrara, Via Ludovico Ariosto 35, 44121 Ferrara (Italy); Frezza, O. [INFN Sezione di Roma, P.le Aldo Moro, 2, 00185 Roma (Italy); Lamanna, G. [INFN, Laboratori Nazionali di Frascati (Italy); Lo Cicero, F.; Lonardo, A.; Martinelli, M.; Neri, I.; Paolucci, P.S.; Pastorelli, E. [INFN Sezione di Roma, P.le Aldo Moro, 2, 00185 Roma (Italy); Piandani, R. [INFN Sezione di Pisa, L. Bruno Pontecorvo, 3, 56127 Pisa (Italy); Pontisso, L., E-mail: luca.pontisso@cern.ch [INFN Sezione di Pisa, L. Bruno Pontecorvo, 3, 56127 Pisa (Italy); Rossetti, D. [NVIDIA Corp., Santa Clara, CA (United States); Simula, F. [INFN Sezione di Roma, P.le Aldo Moro, 2, 00185 Roma (Italy); Sozzi, M. [INFN Sezione di Pisa, L. Bruno Pontecorvo, 3, 56127 Pisa (Italy); Università di Pisa, Lungarno Pacinotti 43, 56126 Pisa (Italy); and others

    2017-02-11

    General-purpose computing on GPUs is emerging as a new paradigm in several fields of science, although so far applications have been tailored to employ GPUs as accelerators in offline computations. With the steady decrease of GPU latencies and the increase in link and memory throughputs, time is ripe for real-time applications using GPUs in high-energy physics data acquisition and trigger systems. We will discuss the use of online parallel computing on GPUs for synchronous low level trigger systems, focusing on tests performed on the trigger of the CERN NA62 experiment. Latencies of all components need analysing, networking being the most critical. To keep it under control, we envisioned NaNet, an FPGA-based PCIe Network Interface Card (NIC) enabling GPUDirect connection. Moreover, we discuss how specific trigger algorithms can be parallelised and thus benefit from a GPU implementation, in terms of increased execution speed. Such improvements are particularly relevant for the foreseen LHC luminosity upgrade where highly selective algorithms will be crucial to maintain sustainable trigger rates with very high pileup.

  8. Validation of ATLAS L1 Topological Triggers

    CERN Document Server

    Praderio, Marco

    2017-01-01

    The Topological trigger (L1Topo) is a new component of the ATLAS L1 (Level-1) trigger. Its purpose is that of reducing the otherwise too high rate of data collection from the LHC by rejecting those events considered “uninteresting” (meaning that they have already been studied). This event rate reduction is achieved by applying topological requirements to the physical objects present in each event. It is very important to make sure that this trigger does not reject any “interesting” event. Therefore we need to verify its correct functioning. The goal of this summer student project is to study the response of two L1Topo algorithms (concerning ∆R and invariant mass). To do so I will compare the trigger decisions produced by the L1Topo hardware with the ones produced by the “official” L1Topo simulation. This way I will be able to identify events that could be incorrectly rejected. Simultaneously I will produce an emulation of these triggers that will help me understand the cause of disagreements bet...

  9. Online software trigger at PANDA/FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Donghee; Kliemt, Ralf; Nerling, Frank [Helmholtz-Institut Mainz (Germany); Denig, Achim [Institut fuer Kernphysik, Universitaet Mainz (Germany); Goetzen, Klaus; Peters, Klaus [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH (Germany); Collaboration: PANDA-Collaboration

    2014-07-01

    The PANDA experiment at FAIR will employ a novel trigger-less read-out system. Since a conventional hardware trigger concept is not suitable for PANDA, a high level online event filter will be applied to perform fast event selection based on physics properties of the reconstructed events. A trigger-less data stream implies an event selection with track reconstruction and pattern recognition to be performed online, and thus analysing data under real time conditions at event rates of up to 40 MHz.The projected data rate reduction of about three orders of magnitude requires an effective background rejection, while retaining interesting signal events. Real time event selection in the environment of hadronic reactions is rather challenging and relies on sophisticated algorithms for the software trigger. The implementation and the performance of physics trigger algorithms presently studied with realistic Monte Carlo simulations is discussed. The impact of parameters such as momentum or mass resolution, PID probability, vertex reconstruction and a multivariate analysis using the TMVA package for event filtering is presented.

  10. The CMS trigger in Run 2

    CERN Document Server

    Tosi, Mia

    2018-01-01

    During its second period of operation (Run 2) which started in 2015, the LHC will reach a peak instantaneous luminosity of approximately 2$\\times 10^{34}$~cm$^{-2}s^{-1}$ with an average pile-up of about 55, far larger than the design value. Under these conditions, the online event selection is a very challenging task. In CMS, it is realised by a two-level trigger system: the Level-1 (L1) Trigger, implemented in custom-designed electronics, and the High Level Trigger (HLT), a streamlined version of the offline reconstruction software running on a computer farm.\\\\ In order to face this challenge, the L1 trigger has undergone a major upgrade compared to Run 1, whereby all electronic boards of the system have been replaced, allowing more sophisticated algorithms to be run online. Its last stage, the global trigger, is now able to perform complex selections and to compute high-level quantities, like invariant masses. Likewise, the algorithms that run in the HLT went through big improvements; in particular, new ap...

  11. The ZEUS calorimeter first level trigger

    Science.gov (United States)

    Silverstein, S.; Ali, I.; Behrens, B.; Foudas, C.; Fordham, C.; Goussiou, A.; Jaworski, M.; Lackey, J.; Reeder, D.; Robl, P.; Smith, W. H.; Vaiciulis, A.; Wodarczyk, M.; Dawson, J.; Krakauer, D.; Talaga, R.; Schlereth, J.; Zhang, H.

    1995-02-01

    An overview of the ZEUS calorimeter first level trigger is presented. The CFLT uses a pipelined architecture to accept and analyze calorimeter data for every 96 ns beam crossing interval. PMT signals are combined by analog electronics into electromagnetic and hadronic sums for 896 trigger towers. The analog sums are then digitized and analyzed. The CFLT determines the total, transverse, and missing transverse energy, identifies isolated electrons and muons, and sums energies in programmable subregions. Calculations are performed in 96 ns steps, and new data are accepted for every beam crossing. Trigger data are forwarded to the global first level trigger (GFLT) after 2 μs, allowing a GFLT accept to be issued 5 μs after the beam crossing which produced the event. Important features of the CFLT include a 12-bit effective dynamic range, extensive use of memory lookup tables for trigger calculations, fast pattern searches for isolated leptons, and low electronics noise. During the 1993 HERA run, the CFLT reduced a 50 kHz background rate to around 100 Hz.

  12. Upper airway resistance syndrome.

    Science.gov (United States)

    Montserrat, J M; Badia, J R

    1999-03-01

    This article reviews the clinical picture, diagnosis and management of the upper airway resistance syndrome (UARS). Presently, there is not enough data on key points like the frequency of UARS and the morbidity associated with this condition. Furthermore, the existence of LIARS as an independent sleep disorder and its relation with snoring and obstructive events is in debate. The diagnosis of UARS is still a controversial issue. The technical limitations of the classic approach to monitor airflow with thermistors and inductance plethysmography, as well as the lack of a precise definition of hypopnea, may have led to a misinterpretation of UARS as an independent diagnosis from the sleep apnea/hypopnea syndrome. The diagnosis of this syndrome can be missed using a conventional polysomnographic setting unless appropriate techniques are applied. The use of an esophageal balloon to monitor inspiratory effort is currently the gold standard. However, other sensitive methods such as the use of a pneumotachograph and, more recently, nasal cannula/pressure transducer systems or on-line monitoring of respiratory impedance with the forced oscillation technique may provide other interesting possibilities. Recognition and characterization of this subgroup of patients within sleep breathing disorders is important because they are symptomatic and may benefit from treatment. Management options to treat UARS comprise all those currently available for sleep apnea/hypopnea syndrome (SAHS). However, the subset of patients classically identified as LIARS that exhibit skeletal craneo-facial abnormalities might possibly obtain further benefit from maxillofacial surgery.

  13. Upper Illinois River basin

    Science.gov (United States)

    Friedel, Michael J.

    1998-01-01

    During the past 25 years, industry and government made large financial investments that resulted in better water quality across the Nation; however, many water-quality concerns remain. Following a 1986 pilot project, the U.S. Geological Survey began implementation of the National Water-Quality Assessment (NAWQA) Program in 1991. This program differs from other national water-quality assessment studies in that the NAWQA integrates monitoring of surface- and ground-water quality with the study of aquatic ecosystems. The goals of the NAWQA Program are to (1) describe current water-quality conditions for a large part of the Nation's freshwater streams and aquifers (water-bearing sediments and rocks), (2) describe how water quality is changing over time, and (3) improve our understanding of the primary natural and human factors affecting water quality.The Upper Illinois River Basin National Water- Quality Assessment (NAWQA) study will increase the scientific understanding of surface- and ground-water quality and the factors that affect water quality in the basin. The study also will provide information needed by water-resource managers to implement effective water-quality management actions and evaluate long-term changes in water quality.

  14. Towards RTOS support for mixed time-triggered and event-triggered task sets

    NARCIS (Netherlands)

    Heuvel, van den M.M.H.P.; Bril, R.J.; Lukkien, J.J.; Isovic, D.; Sankar Ramachandran, G.

    2012-01-01

    Many embedded systems have complex timing constraints and, at the same time, have flexibility requirements which prohibit offline planning of the entire system. To support a mixture of time-triggered and event-triggered tasks, some industrial systems deploy a real-time operating system (RTOS) with a

  15. Limited preemptive scheduling of mixed time-triggered and event-triggered tasks

    NARCIS (Netherlands)

    Heuvel, van den M.M.H.P.; Bril, R.J.; Zhang, X.; Abdullah, S.M.J.; Isovic, D.

    2013-01-01

    Many embedded systems have complex timing constraints and, at the same time, have flexibility requirements which prohibit offline planning of the entire system. To support a mixture of time-triggered and event-triggered tasks, some industrial systems deploy a table-driven dispatcher for

  16. Performance of the ATLAS Muon Trigger and Phase-1 Upgrade of Level-1 Endcap Muon Trigger

    CERN Document Server

    Mizukami, Atsushi; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment utilises a trigger system to efficiently record interesting events. It consists of first-level and high-level triggers. The first-level trigger is implemented with custom-built hardware to reduce the event rate from 40 MHz to100 kHz. Then the software-based high-level triggers refine the trigger decisions reducing the output rate down to 1 kHz. Events with muons in the final state are an important signature for many physics topics at the LHC. An efficient trigger on muons and a detailed understanding of its performance are required. Trigger efficiencies are, for example, obtained from the muon decay of Z boson, with a Tag&Probe method, using proton-proton collision data collected in 2016 at a centre-of-mass energy of 13 TeV. The LHC is expected to increase its instantaneous luminosity to $3\\times10^{34} \\rm{cm^{-2}s^{-1}}$ after the phase-1 upgrade between 2018-2020. The upgrade of the ATLAS trigger system is mandatory to cope with this high-luminosity. In the phase-1 upgrade, new det...

  17. The BTeV trigger system

    International Nuclear Information System (INIS)

    Kaplan, D.M.

    2000-01-01

    BTeV is a dedicated beauty and charm experiment proposed for the Fermilab Tevatron. The broad physics program envisaged for BTeV requires a trigger that is efficient for a wide variety of heavy-quark decays, including those to all-hadronic final states. To achieve this, we plan to trigger on evidence of detached vertices at the very first trigger level, taking advantage of fast-readout pixel detectors to facilitate fast pattern recognition. Simulations show that 100-to-1 rejection of light-quark background events can be achieved at Level 1 using specialized trackfinding hardware, and that an additional factor of 10-100 in data reduction can be achieved using general purpose processor farms at Levels 2 and 3. This is adequate to allow data taking at luminosities in excess of 2x10 32 cm -2 s -1

  18. Use of GPUs in Trigger Systems

    Science.gov (United States)

    Lamanna, Gianluca

    In recent years the interest for using graphics processor (GPU) in general purpose high performance computing is constantly rising. In this paper we discuss the possible use of GPUs to construct a fast and effective real time trigger system, both in software and hardware levels. In particular, we study the integration of such a system in the NA62 trigger. The first application of GPUs for rings pattern recognition in the RICH will be presented. The results obtained show that there are not showstoppers in trigger systems with relatively low latency. Thanks to the use of off-the-shelf technology, in continous development for purposes related to video game and image processing market, the architecture described would be easily exported to other experiments, to build a versatile and fully customizable online selection.

  19. The ATLAS Electron and Photon Trigger

    CERN Document Server

    Jones, Samuel David; The ATLAS collaboration

    2018-01-01

    ATLAS electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential to record signals for a wide variety of physics: from Standard Model processes to searches for new phenomena. To cope with ever-increasing luminosity and more challenging pile-up conditions at a centre-of-mass energy of 13 TeV, the trigger selections need to be optimized to control the rates and keep efficiencies high. The ATLAS electron and photon trigger performance in Run 2 will be presented, including both the role of the ATLAS calorimeter in electron and photon identification and details of new techniques developed to maintain high performance even in high pile-up conditions.

  20. Combining triggers in HEP data analysis

    International Nuclear Information System (INIS)

    Lendermann, Victor; Herbst, Michael; Krueger, Katja; Schultz-Coulon, Hans-Christian; Stamen, Rainer; Haller, Johannes

    2009-01-01

    Modern high-energy physics experiments collect data using dedicated complex multi-level trigger systems which perform an online selection of potentially interesting events. In general, this selection suffers from inefficiencies. A further loss of statistics occurs when the rate of accepted events is artificially scaled down in order to meet bandwidth constraints. An offline analysis of the recorded data must correct for the resulting losses in order to determine the original statistics of the analysed data sample. This is particularly challenging when data samples recorded by several triggers are combined. In this paper we present methods for the calculation of the offline corrections and study their statistical performance. Implications on building and operating trigger systems are discussed. (orig.)

  1. Combining triggers in HEP data analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lendermann, Victor; Herbst, Michael; Krueger, Katja; Schultz-Coulon, Hans-Christian; Stamen, Rainer [Heidelberg Univ. (Germany). Kirchhoff-Institut fuer Physik; Haller, Johannes [Hamburg Univ. (Germany). Institut fuer Experimentalphysik

    2009-01-15

    Modern high-energy physics experiments collect data using dedicated complex multi-level trigger systems which perform an online selection of potentially interesting events. In general, this selection suffers from inefficiencies. A further loss of statistics occurs when the rate of accepted events is artificially scaled down in order to meet bandwidth constraints. An offline analysis of the recorded data must correct for the resulting losses in order to determine the original statistics of the analysed data sample. This is particularly challenging when data samples recorded by several triggers are combined. In this paper we present methods for the calculation of the offline corrections and study their statistical performance. Implications on building and operating trigger systems are discussed. (orig.)

  2. A new fast and programmable trigger logic

    International Nuclear Information System (INIS)

    Fucci, A.; Amendolia, S.R.; Bertolucci, E.; Bottigli, U.; Bradaschia, C.; Foa, L.; Giazotto, A.; Giorgi, M.; Givoletti, M.; Lucardesi, P.; Menzione, A.; Passuello, D.; Quaglia, M.; Ristori, L.; Rolandi, L.; Salvadori, P.; Scribano, A.; Stanga, R.; Stefanini, A.; Vincelli, M.L.

    1977-01-01

    The NA1 (FRAMM) experiment, under construction for the CERN-SPS North Area, deals with more than 1000 counter signals which have to be combined together in order to build sophisticated and highly selective triggers. These requirements have led to the development of a low cost, combinatorial, fast electronics which can replace, in an advantageous way the standard NIM electronics at the trigger level. The essential performances of the basic circuit are: 1) programmability of any desired logical expression; 2) trigger time independent of the chosen expression; 3) reduced cost and compactness due to the use of commercial RAMs, PROMs, and PLAs; 4) short delay, less than 20 ns, between input and output pulses. (Auth.)

  3. FTK: a Fast Track Trigger for ATLAS

    International Nuclear Information System (INIS)

    Anderson, J; Auerbach, B; Blair, R; Andreani, A; Andreazza, A; Citterio, M; Annovi, A; Beretta, M; Castegnaro, A; Atkinson, M; Cavaliere, V; Chang, P; Bevacqua, V; Crescioli, F; Blazey, G; Bogdan, M; Boveia, A; Canelli, F; Cheng, Y; Cervigni, F

    2012-01-01

    We describe the design and expected performance of a the Fast Tracker Trigger (FTK) system for the ATLAS detector at the Large Hadron Collider. The FTK is a highly parallel hardware system designed to operate at the Level 1 trigger output rate. It is designed to provide global tracks reconstructed in the inner detector with resolution comparable to the full offline reconstruction as input of the Level 2 trigger processing. The hardware system is based on associative memories for pattern recognition and fast FPGAs for track reconstruction. The FTK is expected to dramatically improve the performance of track based isolation and b-tagging with little to no dependencies of pile-up interactions.

  4. A self triggered intensified Ccd (Stic)

    International Nuclear Information System (INIS)

    Charon, Y.; Laniece, P.; Bendali, M.

    1990-01-01

    We are developing a new device based on the results reported previously of the successfull coincidence detection of β- particles with a high spatial resolution [1]. The novelty of the device consists in triggering an intensified CCD, i.e. a CCD coupled to an image intensifier (II), by an electrical signal collected from the II itself. This is a suitable procedure for detecting with high efficiency and high resolution low light rare events. The trigger pulse is obtained from the secondary electrons produced by multiplication in a double microchannel plate (MCP) and collected on the aluminized layer protecting the phosphor screen in the II. Triggering efficiencies up to 80% has been already achieved

  5. The UA1 upgrade calorimeter trigger processor

    International Nuclear Information System (INIS)

    Bains, M.; Charleton, D.; Ellis, N.; Garvey, J.; Gregory, J.; Jimack, M.P.; Jovanovic, P.; Kenyon, I.R.; Baird, S.A.; Campbell, D.; Cawthraw, M.; Coughlan, J.; Flynn, P.; Galagedera, S.; Grayer, G.; Halsall, R.; Shah, T.P.; Stephens, R.; Biddulph, P.; Eisenhandler, E.; Fensome, I.F.; Landon, M.; Robinson, D.; Oliver, J.; Sumorok, K.

    1990-01-01

    The increased luminosity of the improved CERN Collider and the more subtle signals of second-generation collider physics demand increasingly sophisticated triggering. We have built a new first-level trigger processor designed to use the excellent granularity of the UA1 upgrade calorimeter. This device is entirely digital and handles events in 1.5 μs, thus introducing no dead time. Its most novel feature is fast two-dimensional electromagnetic cluster-finding with the possibility of demanding an isolated shower of limited penetration. The processor allows multiple combinations of triggers on electromagnetic showers, hadronic jets and energy sums, including a total-energy veto of multiple interactions and a full vector sum of missing transverse energy. This hard-wired processor is about five times more powerful than its predecessor, and makes extensive use of pipelining techniques. It was used extensively in the 1988 and 1989 runs of the CERN Collider. (orig.)

  6. The UA1 upgrade calorimeter trigger processor

    International Nuclear Information System (INIS)

    Bains, N.; Baird, S.A.; Biddulph, P.

    1990-01-01

    The increased luminosity of the improved CERN Collider and the more subtle signals of second-generation collider physics demand increasingly sophisticated triggering. We have built a new first-level trigger processor designed to use the excellent granularity of the UA1 upgrade calorimeter. This device is entirely digital and handles events in 1.5 μs, thus introducing no deadtime. Its most novel feature is fast two-dimensional electromagnetic cluster-finding with the possibility of demanding an isolated shower of limited penetration. The processor allows multiple combinations of triggers on electromagnetic showers, hadronic jets and energy sums, including a total-energy veto of multiple interactions and a full vector sum of missing transverse energy. This hard-wired processor is about five times more powerful than its predecessor, and makes extensive use of pipelining techniques. It was used extensively in the 1988 and 1989 runs of the CERN Collider. (author)

  7. The double Chooz hardware trigger system

    Energy Technology Data Exchange (ETDEWEB)

    Cucoanes, Andi; Beissel, Franz; Reinhold, Bernd; Roth, Stefan; Stahl, Achim; Wiebusch, Christopher [RWTH Aachen (Germany)

    2008-07-01

    The double Chooz neutrino experiment aims to improve the present knowledge on {theta}{sub 13} mixing angle using two similar detectors placed at {proportional_to}280 m and respectively 1 km from the Chooz power plant reactor cores. The detectors measure the disappearance of reactor antineutrinos. The hardware trigger has to be very efficient for antineutrinos as well as for various types of background events. The triggering condition is based on discriminated PMT sum signals and the multiplicity of groups of PMTs. The talk gives an outlook to the double Chooz experiment and explains the requirements of the trigger system. The resulting concept and its performance is shown as well as first results from a prototype system.

  8. Self-triggering superconducting fault current limiter

    Science.gov (United States)

    Yuan, Xing [Albany, NY; Tekletsadik, Kasegn [Rexford, NY

    2008-10-21

    A modular and scaleable Matrix Fault Current Limiter (MFCL) that functions as a "variable impedance" device in an electric power network, using components made of superconducting and non-superconducting electrically conductive materials. The matrix fault current limiter comprises a fault current limiter module that includes a superconductor which is electrically coupled in parallel with a trigger coil, wherein the trigger coil is magnetically coupled to the superconductor. The current surge doing a fault within the electrical power network will cause the superconductor to transition to its resistive state and also generate a uniform magnetic field in the trigger coil and simultaneously limit the voltage developed across the superconductor. This results in fast and uniform quenching of the superconductors, significantly reduces the burnout risk associated with non-uniformity often existing within the volume of superconductor materials. The fault current limiter modules may be electrically coupled together to form various "n" (rows).times."m" (columns) matrix configurations.

  9. Dendrite Injury Triggers DLK-Independent Regeneration

    Directory of Open Access Journals (Sweden)

    Michelle C. Stone

    2014-01-01

    Full Text Available Axon injury triggers regeneration through activation of a conserved kinase cascade, which includes the dual leucine zipper kinase (DLK. Although dendrites are damaged during stroke, traumatic brain injury, and seizure, it is not known whether mature neurons monitor dendrite injury and initiate regeneration. We probed the response to dendrite damage using model Drosophila neurons. Two larval neuron types regrew dendrites in distinct ways after all dendrites were removed. Dendrite regeneration was also triggered by injury in adults. Next, we tested whether dendrite injury was initiated with the same machinery as axon injury. Surprisingly, DLK, JNK, and fos were dispensable for dendrite regeneration. Moreover, this MAP kinase pathway was not activated by injury to dendrites. Thus, neurons respond to dendrite damage and initiate regeneration without using the conserved DLK cascade that triggers axon regeneration.

  10. The ZEUS second level calorimeter trigger

    International Nuclear Information System (INIS)

    Jong, S.J. de.

    1990-01-01

    ZEUS is a detector for the HERA ep collider, consisting of several large components. The most important being the inner tracking detectors, which are positioned nearest to the interaction point, the calorimeter surrounding the inner tracking detectors and the muon detectors on the outside of the experimental setup. Each component will deliver a vast amount of information. In order to keep this information manageable, data is preprocessed and condensed per component and then combined to obtain the final global trigger result. The main subject of this thesis is the second level calorimeter trigger processor of the ZEUS detector. In order to be able to reject the unwanted events passing the first level, the topological event signature will have to be used at the second level. The most demanding task of the second level is the recognition of local energy depositions corresponding to isolated electrons and hadron jets. Also part of the work performed by the first level will be repeated with a higher level of accuracy. Additional information not available to the first level trigger will be processed and will be made available to the global second level trigger decision module. For the second level calorimeter trigger processor a special VME module, containing two transputers, has been developed. The second level calorimeter trigger algorithm described in this thesis was tested with simulated events, that were tracked through a computer simulation of the ZEUS detector. A part of this thesis is therefore devoted to the description of the various Monte Carlo models and the justification of the way in which they were used. (author). 132 refs.; 76 figs.; 18 tabs

  11. The ATLAS trigger: high-level trigger commissioning and operation during early data taking

    International Nuclear Information System (INIS)

    Goncalo, R

    2008-01-01

    The ATLAS experiment is one of the two general-purpose experiments due to start operation soon at the Large Hadron Collider (LHC). The LHC will collide protons at a centre of mass energy of 14 TeV, with a bunch-crossing rate of 40 MHz. The ATLAS three-level trigger will reduce this input rate to match the foreseen offline storage capability of 100-200 Hz. This paper gives an overview of the ATLAS High Level Trigger focusing on the system design and its innovative features. We then present the ATLAS trigger strategy for the initial phase of LHC exploitation. Finally, we report on the valuable experience acquired through in-situ commissioning of the system where simulated events were used to exercise the trigger chain. In particular we show critical quantities such as event processing times, measured in a large-scale HLT farm using a complex trigger menu

  12. Thoracic Outlet Syndrome and Volkmann's Contracture in a Field Hockey Player

    Directory of Open Access Journals (Sweden)

    Morgan Sawyer

    2016-05-01

    Full Text Available Background: A 19-year-old female field hockey player presents with bilateral upper trapezius and rhomboid tightness and spasm beginning in January of 2016. She has no previous history of upper back pain or injury. The student first reported the injury immediately after running sprints. She stated that she could not move or feel her fingers or hands. She presents with a visible hump on her left upper trapezius. She also has forward-rounded shoulders. She has regular and equal radial pulses. She has decreased sensation upon palpation of her fingers, hands and forearms. After extraneous exercise, the athlete’s hands, wrists and forearms go into contracture and flexion and she is unable to move from this position until manual extension is applied, or 10 or more minutes of rest occurs. She is TTP over her upper trapezius musculature. She had a positive Military Brace test. Differential Diagnosis: Based on evaluation, the athlete could simply just have upper trapezius musculature spasms. The diagnosis could also be shoulder impingement syndrome, due to the neurological signs and symptoms. Compartment syndrome could produce similar s/s that the athlete experiences, as well. Treatment: X-rays show no bony abnormalities and no extra ribs. The athlete’s injury has been treated with ice post-practice, heat pre-practice and upper body stretching exercises. Three days a week the athlete works on postural exercises that strengthen her back musculature. The athlete also receives combination therapy over her upper trapezius trigger points, along with massage and Hawkgrip technique over the same areas. Uniqueness: The uniqueness in this case is that the athlete has both TOS and Volkmann’s contracture. Volkmann’s contractures typically occur in pediatrics, which is another reason why this particular case is unique. Conclusion: This case allows other clinicians to understand the causes of TOS and the secondary s/s that TOS can potentially cause.

  13. Self triggered single pulse beam position monitor

    International Nuclear Information System (INIS)

    Rothman, J.L.; Blum, E.B.

    1993-01-01

    A self triggered beam position monitor (BPM) has been developed for the NSLS injection system to provide single pulse orbit measurements in the booster synchrotron, linac, and transport lines. The BPM integrates the negative going portion of 3 nS wide bipolar pickup electrode signals. The gated, self triggering feature confines critical timing components to the front end, relaxing external timing specifications. The system features a low noise high speed FET sampler, a fiber optic gate for bunch and turn selection, and an inexpensive interface to a standard PC data acquisition system

  14. Run 2 ATLAS Trigger and Detector Performance

    CERN Document Server

    Solovyanov, Oleg; The ATLAS collaboration

    2018-01-01

    The 2nd LHC run has started in June 2015 with a proton-proton centre-of-mass collision energy of 13 TeV. During the years 2016 and 2017, LHC delivered an unprecedented amount of luminosity under the ever-increasing challenging conditions in terms of peak luminosity, pile-up and trigger rates. In this talk, the LHC running conditions and the improvements made to the ATLAS experiment in the course of Run 2 will be discussed, and the latest ATLAS detector and ATLAS trigger performance results from the Run 2 will be presented.

  15. Advances in tracking and trigger concepts

    International Nuclear Information System (INIS)

    Kisel, Ivan

    2014-01-01

    Increasing beam intensities and input data rates require to rethink the traditional approaches in trigger concepts. At the same time the advanced many-core computer architectures providing new dimensions in programming require to rework the standard methods or to develop new methods of track reconstruction in order to efficiently use parallelism of the computer hardware. As a results a new tendency appears to replace the standard (usually implemented in FPGA) hardware triggers by clusters of computers running software reconstruction and selection algorithms. In addition that makes possible unification of the offline and on-line data processing and analysis in one software package running on a heterogeneous computer farm

  16. The CMS High-Level Trigger

    International Nuclear Information System (INIS)

    Covarelli, R.

    2009-01-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the 'High-Level Trigger'(HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, τ leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  17. The CMS High-Level Trigger

    CERN Document Server

    Covarelli, Roberto

    2009-01-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the "High-Level Trigger" (HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, tau leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  18. The CMS High-Level Trigger

    Science.gov (United States)

    Covarelli, R.

    2009-12-01

    At the startup of the LHC, the CMS data acquisition is expected to be able to sustain an event readout rate of up to 100 kHz from the Level-1 trigger. These events will be read into a large processor farm which will run the "High-Level Trigger" (HLT) selection algorithms and will output a rate of about 150 Hz for permanent data storage. In this report HLT performances are shown for selections based on muons, electrons, photons, jets, missing transverse energy, τ leptons and b quarks: expected efficiencies, background rates and CPU time consumption are reported as well as relaxation criteria foreseen for a LHC startup instantaneous luminosity.

  19. Popular sweetner sucralose as a migraine trigger.

    Science.gov (United States)

    Patel, Rajendrakumar M; Sarma, Rakesh; Grimsley, Edwin

    2006-09-01

    Sucralose (trichlorogalactosucrose, or better known as Splenda) is an artificial sweetener from native sucrose that was approved by the FDA on April 1, 1998 (April Fool's Day). This observation of a potential causal relationship between sucralose and migraines may be important for physicians to remember this can be a possible trigger during dietary history taking. Identifying further triggers for migraine headaches, in this case sucralose, may help alleviate some of the cost burden (through expensive medical therapy or missed work opportunity) as well as provide relief to migraineurs.

  20. CMS Calorimeter Trigger Phase I upgrade

    International Nuclear Information System (INIS)

    Klabbers, P; Gorski, T; Bachtis, M; Dasu, S; Fobes, R; Grothe, M; Ross, I; Smith, W H; Compton, K; Farmahini-Farahani, A; Gregerson, A; Seemuth, D; Schulte, M

    2012-01-01

    We present a design for the Phase-1 upgrade of the Compact Muon Solenoid (CMS) calorimeter trigger system composed of FPGAs and Multi-GBit/sec links that adhere to the μTCA crate Telecom standard. The upgrade calorimeter trigger will implement algorithms that create collections of isolated and non-isolated electromagnetic objects, isolated and non-isolated tau objects and jet objects. The algorithms are organized in several steps with progressive data reduction. These include a particle cluster finder that reconstructs overlapping clusters of 2x2 calorimeter towers and applies electron identification, a cluster overlap filter, particle isolation determination, jet reconstruction, particle separation and sorting.

  1. Hardware trigger processor for the MDT system

    CERN Document Server

    AUTHOR|(SzGeCERN)757787; The ATLAS collaboration; Hazen, Eric; Butler, John; Black, Kevin; Gastler, Daniel Edward; Ntekas, Konstantinos; Taffard, Anyes; Martinez Outschoorn, Verena; Ishino, Masaya; Okumura, Yasuyuki

    2017-01-01

    We are developing a low-latency hardware trigger processor for the Monitored Drift Tube system in the Muon spectrometer. The processor will fit candidate Muon tracks in the drift tubes in real time, improving significantly the momentum resolution provided by the dedicated trigger chambers. We present a novel pure-FPGA implementation of a Legendre transform segment finder, an associative-memory alternative implementation, an ARM (Zynq) processor-based track fitter, and compact ATCA carrier board architecture. The ATCA architecture is designed to allow a modular, staged approach to deployment of the system and exploration of alternative technologies.

  2. Upper limb muscular activity and perceived workload during laryngoscopy: comparison of Glidescope(R) and Macintosh laryngoscopy in manikin: an observational study.

    Science.gov (United States)

    Caldiroli, D; Molteni, F; Sommariva, A; Frittoli, S; Guanziroli, E; Cortellazzi, P; Orena, E F

    2014-03-01

    The interaction between operators and their working environment during laryngoscopy is poorly understood. Numerous studies have focused on the forces applied to the patient's airway during laryngoscopy, but only a few authors have addressed operator muscle activity and workload. We tested whether different devices (Glidescope(®) and Macintosh) use different muscles and how these differences affect the perceived workload. Ten staff anaesthetists performed three intubations with each device on a manikin. Surface electromyography was recorded for eight single muscles of the left upper limb. The NASA Task Load Index (TLX) was administered after each experimental session to evaluate perceived workload. A consistent reduction in muscular activation occurred with Glidescope(®) compared with Macintosh for all muscles tested (mean effect size d=3.28), and significant differences for the upper trapezius (P=0.002), anterior deltoid (P=0.001), posterior deltoid (P=0.000), and brachioradialis (P=0.001) were observed. The overall NASA-TLX workload score was significantly lower for Glidescope(®) than for Macintosh (P=0.006), and the factors of physical demand (P=0.008) and effort (P=0.006) decreased significantly. Greater muscular activity and workload were observed with the Macintosh laryngoscope. Augmented vision and related postural adjustments related to using the Glidescope(®) may reduce activation of the operator's muscles and task workload.

  3. A trigger simulation framework for the ALICE experiment

    International Nuclear Information System (INIS)

    Antinori, F; Carminati, F; Gheata, A; Gheata, M

    2011-01-01

    A realistic simulation of the trigger system in a complex HEP experiment is essential for performing detailed trigger efficiency studies. The ALICE trigger simulation is evolving towards a framework capable of replaying the full trigger chain starting from the input to the individual trigger processors and ending with the decision mechanisms of the ALICE central trigger processor. This paper describes the new ALICE trigger simulation framework that is being tested and deployed. The framework handles details like trigger levels, signal delays and busy signals, implementing the trigger logic via customizable trigger device objects managed by a robust scheduling mechanism. A big advantage is the high flexibility of the framework, which is able to mix together components described with very different levels of detail. The framework is being gradually integrated within the ALICE simulation and reconstruction frameworks.

  4. Towards a Level-1 Tracking Trigger for the ATLAS Experiment

    CERN Document Server

    De Santo, A; The ATLAS collaboration

    2016-01-01

    In preparation for the high-luminosity phase of the Large Hadron Collider, ATLAS is planning a trigger upgrade that will enable the experiment to use tracking information already at the first trigger level. This will provide enhanced background rejection power at trigger level while preserving much needed flexibility for the trigger system. The status and current plans for the new ATLAS Level-1 tracking trigger are presented.

  5. UA1 upgrade first-level calorimeter trigger processor

    International Nuclear Information System (INIS)

    Bains, N.; Charlton, D.; Ellis, N.; Garvey, J.; Gregory, J.; Jimack, M.P.; Jovanovic, P.; Kenyon, I.R.; Baird, S.A.; Campbell, D.; Cawthraw, M.; Coughlan, J.; Flynn, P.; Galagedera, S.; Grayer, G.; Halsall, R.; Shah, T.P.; Stephens, R.; Eisenhandler, E.; Fensome, I.; Landon, M.

    1989-01-01

    A new first-level trigger processor has been built for the UA1 experiment on the Cern SppS Collider. The processor exploits the fine granularity of the new UA1 uranium-TMP calorimeter to improve the selectivity of the trigger. The new electron trigger has improved hadron jet rejection, achieved by requiring low energy deposition around the electromagnetic cluster. A missing transverse energy trigger and a total energy trigger have also been implemented. (orig.)

  6. Prostate cancer may trigger paraneoplastic limbic encephalitis

    DEFF Research Database (Denmark)

    Jakobsen, Jakob Kristian; Zakharia, Elias Raja; Boysen, Anders Kindberg Fossø

    2013-01-01

    -Hu antibody test the patient was diagnosed with paraneoplastic limbic encephalitis related to prostate cancer. The patient died within 6 months. We review the literature on prostate cancer-related paraneoplastic limbic encephalitis. High-risk prostate cancer can trigger paraneoplastic limbic encephalitis...

  7. Entity models for trigger-reaction documents

    NARCIS (Netherlands)

    Khalid, M.A.; Marx, M.; Makkes, M.X.

    2008-01-01

    We define the notion of an entity model for a special kind of document popular on the web: an article followed by a list of reactions on that article, usually by many authors, usually inverse chronologically ordered. We call these documents trigger-reactions pairs. The entity model describes which

  8. Hard scattering and a diffractive trigger

    International Nuclear Information System (INIS)

    Berger, E.L.; Collins, J.C.; Soper, D.E.; Sterman, G.

    1986-02-01

    Conclusions concerning the properties of hard scattering in diffractively produced systems are summarized. One motivation for studying diffractive hard scattering is to investigate the interface between Regge theory and perturbative QCD. Another is to see whether diffractive triggering can result in an improvement in the signal-to-background ratio of measurements of production of very heavy quarks. 5 refs

  9. 2017 B-Physics trigger efficiencies

    CERN Document Server

    CMS Collaboration

    2018-01-01

    The performance of the trigger used to select B-Physics decay channels in CMS is presented for data collected in 2017, corresponding to an integrated luminosity of $9.8\\,\\mathrm{fb}^{-1}$ at $13\\,\\mathrm{TeV}$.

  10. Self-triggered coordination with ternary controllers

    NARCIS (Netherlands)

    De Persis, Claudio; Frasca, Paolo

    2012-01-01

    This paper regards coordination of networked systems with ternary controllers. We develop a hybrid coordination system which implements a self-triggered communication policy, based on polling the neighbors upon need. We prove that the proposed scheme ensures finite-time convergence to a neighborhood

  11. BTeV trigger/DAQ innovations

    International Nuclear Information System (INIS)

    Votava, Margaret

    2005-01-01

    The BTeV experiment was a collider based high energy physics (HEP) B-physics experiment proposed at Fermilab. It included a large-scale, high speed trigger/data acquisition (DAQ) system, reading data off the detector at 500 Gbytes/sec and writing to mass storage at 200 Mbytes/sec. The online design was considered to be highly credible in terms of technical feasibility, schedule and cost. This paper will give an overview of the overall trigger/DAQ architecture, highlight some of the challenges, and describe the BTeV approach to solving some of the technical challenges. At the time of termination in early 2005, the experiment had just passed its baseline review. Although not fully implemented, many of the architecture choices, design, and prototype work for the online system (both trigger and DAQ) were well on their way to completion. Other large, high-speed online systems may have interest in the some of the design choices and directions of BTeV, including (a) a commodity-based tracking trigger running asynchronously at full rate, (b) the hierarchical control and fault tolerance in a large real time environment, (c) a partitioning model that supports offline processing on the online farms during idle periods with plans for dynamic load balancing, and (d) an independent parallel highway architecture

  12. Event Reconstruction Algorithms for the ATLAS Trigger

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca-Martin, T.; /CERN; Abolins, M.; /Michigan State U.; Adragna, P.; /Queen Mary, U. of London; Aleksandrov, E.; /Dubna, JINR; Aleksandrov, I.; /Dubna, JINR; Amorim, A.; /Lisbon, LIFEP; Anderson, K.; /Chicago U., EFI; Anduaga, X.; /La Plata U.; Aracena, I.; /SLAC; Asquith, L.; /University Coll. London; Avolio, G.; /CERN; Backlund, S.; /CERN; Badescu, E.; /Bucharest, IFIN-HH; Baines, J.; /Rutherford; Barria, P.; /Rome U. /INFN, Rome; Bartoldus, R.; /SLAC; Batreanu, S.; /Bucharest, IFIN-HH /CERN; Beck, H.P.; /Bern U.; Bee, C.; /Marseille, CPPM; Bell, P.; /Manchester U.; Bell, W.H.; /Glasgow U. /Pavia U. /INFN, Pavia /Regina U. /CERN /Annecy, LAPP /Paris, IN2P3 /Royal Holloway, U. of London /Napoli Seconda U. /INFN, Naples /Argonne /CERN /UC, Irvine /Barcelona, IFAE /Barcelona, Autonoma U. /CERN /Montreal U. /CERN /Glasgow U. /Michigan State U. /Bucharest, IFIN-HH /Napoli Seconda U. /INFN, Naples /New York U. /Barcelona, IFAE /Barcelona, Autonoma U. /Salento U. /INFN, Lecce /Pisa U. /INFN, Pisa /Bucharest, IFIN-HH /UC, Irvine /CERN /Glasgow U. /INFN, Genoa /Genoa U. /Lisbon, LIFEP /Napoli Seconda U. /INFN, Naples /UC, Irvine /Valencia U. /Rio de Janeiro Federal U. /University Coll. London /New York U.; /more authors..

    2011-11-09

    The ATLAS experiment under construction at CERN is due to begin operation at the end of 2007. The detector will record the results of proton-proton collisions at a center-of-mass energy of 14 TeV. The trigger is a three-tier system designed to identify in real-time potentially interesting events that are then saved for detailed offline analysis. The trigger system will select approximately 200 Hz of potentially interesting events out of the 40 MHz bunch-crossing rate (with 10{sup 9} interactions per second at the nominal luminosity). Algorithms used in the trigger system to identify different event features of interest will be described, as well as their expected performance in terms of selection efficiency, background rejection and computation time per event. The talk will concentrate on recent improvements and on performance studies, using a very detailed simulation of the ATLAS detector and electronics chain that emulates the raw data as it will appear at the input to the trigger system.

  13. Multiple output timing and trigger generator

    Energy Technology Data Exchange (ETDEWEB)

    Wheat, Robert M. [Los Alamos National Laboratory; Dale, Gregory E [Los Alamos National Laboratory

    2009-01-01

    In support of the development of a multiple stage pulse modulator at the Los Alamos National Laboratory, we have developed a first generation, multiple output timing and trigger generator. Exploiting Commercial Off The Shelf (COTS) Micro Controller Units (MCU's), the timing and trigger generator provides 32 independent outputs with a timing resolution of about 500 ns. The timing and trigger generator system is comprised of two MCU boards and a single PC. One of the MCU boards performs the functions of the timing and signal generation (the timing controller) while the second MCU board accepts commands from the PC and provides the timing instructions to the timing controller. The PC provides the user interface for adjusting the on and off timing for each of the output signals. This system provides 32 output or timing signals which can be pre-programmed to be in an on or off state for each of 64 time steps. The width or duration of each of the 64 time steps is programmable from 2 {micro}s to 2.5 ms with a minimum time resolution of 500 ns. The repetition rate of the programmed pulse train is only limited by the time duration of the programmed event. This paper describes the design and function of the timing and trigger generator system and software including test results and measurements.

  14. Performance of the CMS High Level Trigger

    CERN Document Server

    Perrotta, Andrea

    2015-01-01

    The CMS experiment has been designed with a 2-level trigger system. The first level is implemented using custom-designed electronics. The second level is the so-called High Level Trigger (HLT), a streamlined version of the CMS offline reconstruction software running on a computer farm. For Run II of the Large Hadron Collider, the increases in center-of-mass energy and luminosity will raise the event rate to a level challenging for the HLT algorithms. The increase in the number of interactions per bunch crossing, on average 25 in 2012, and expected to be around 40 in Run II, will be an additional complication. We present here the expected performance of the main triggers that will be used during the 2015 data taking campaign, paying particular attention to the new approaches that have been developed to cope with the challenges of the new run. This includes improvements in HLT electron and photon reconstruction as well as better performing muon triggers. We will also present the performance of the improved trac...

  15. ALICE Trigger and Event Selection QA

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    I will present the last nine weeks of work on building a class that efficiently produces trending physics selection of various trigger classes for the purposes of quality assurance. This class is easily generalizable and will be used for live monitoring via a webpage.

  16. Triggering on electrons and photons with CMS

    Directory of Open Access Journals (Sweden)

    Zabi Alexandre

    2012-06-01

    Full Text Available Throughout the year 2011, the Large Hadron Collider (LHC has operated with an instantaneous luminosity that has risen continually to around 4 × 1033cm−2s−1. With this prodigious high-energy proton collisions rate, efficient triggering on electrons and photons has become a major challenge for the LHC experiments. The Compact Muon Solenoid (CMS experiment implements a sophisticated two-level online selection system that achieves a rejection factor of nearly 106. The first level (L1 is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger (HLT combines fine-grain information from all sub-detectors. In this intense hadronic environment, the L1 electron/photon trigger provides a powerful tool to select interesting events. It is based upon information from the Electromagnetic Calorimeter (ECAL, a high-resolution detector comprising 75848 lead tungstate (PbWO4 crystals in a “barrel” and two “endcaps”. The performance as well as the optimization of the electron/photon trigger are presented.

  17. Reflex epilepsy: triggers and management strategies

    Directory of Open Access Journals (Sweden)

    Okudan ZV

    2018-01-01

    Full Text Available Zeynep Vildan Okudan,1 Çiğdem Özkara2 1Department of Neurology, Bakirkoy Dr Sadi Konuk Education and Research Hospital, 2Department of Neurology and Clinical Neurophysiology, Cerrahpasa Faculty of Medicine, University of Istanbul, Istanbul, Turkey Abstract: Reflex epilepsies (REs are identified as epileptic seizures that are consistently induced by identifiable and objective-specific triggers, which may be an afferent stimulus or by the patient’s own activity. RE may have different subtypes depending on the stimulus characteristic. There are significant clinical and electrophysiologic differences between different RE types. Visual stimuli-sensitive or photosensitive epilepsies constitute a large proportion of the RE and are mainly related to genetic causes. Reflex epilepsies may present with focal or generalized seizures due to specific triggers, and sometimes seizures may occur spontaneously. The stimuli can be external (light flashes, hot water, internal (emotion, thinking, or both and should be distinguished from triggering precipitants, which most epileptic patients could report such as emotional stress, sleep deprivation, alcohol, and menstrual cycle. Different genetic and acquired factors may play a role in etiology of RE. This review will provide a current overview of the triggering factors and management of reflex seizures. Keywords: seizure, reflex epilepsy, photosensitivity, hot water, reading, thinking

  18. Does heavy physical exertion trigger myocardial infarction?

    DEFF Research Database (Denmark)

    Hallqvist, J; Möller, J; Ahlbom, A

    2000-01-01

    To study possible triggering of first events of acute myocardial infarction by heavy physical exertion, the authors conducted a case-crossover analysis (1993-1994) within a population-based case-referent study in Stockholm County, Sweden (the Stockholm Heart Epidemiology Program). Interviews were...

  19. The CMS Barrel Muon Trigger Upgrade

    CERN Document Server

    Triossi, Andrea

    2017-01-01

    ABSTRACT: The increase of luminosity expected by LHC during Phase 1 will impose several constrains for rate reduction while maintaining high efficiency in the CMS Level 1 trigger system. The TwinMux system is the early layer of the muon barrel region that concentrates the information from different subdetectors DT, RPC and HO. It arranges and fan-out the slow optical trigger links from the detector chambers into faster links (10 Gbps) that are sent to the track finders. Results, from collision runs, that confirm the satisfactory operation of the trigger system up to the output of the barrel track finder, will be shown. SUMMARY: In view of the increase of luminosity during phase 1 upgrade of LHC, the muon trigger chain of the Compact Muon Solenoid (CMS) experiment underwent considerable improvements. The muon detector was designed for preserving the complementarity and redundancy of three separate muon detection systems, Cathode Strip Chambers (CSC), Drift Tubes (DT) and Resistive Plate Chambers (RPC), until ...

  20. Trigger factors and mechanisms in migraine

    NARCIS (Netherlands)

    Schoonman, Geurt Gerhard

    2008-01-01

    Migraine is a severe headache syndrome, affecting approximately 33% of females and 13% of males. Patients suffer from recurring headache episodes in combination with nausea, vomiting, phono and photophobia. It is a paroxysmal disorder for which several several trigger factors have been identified by

  1. BTeV detached vertex trigger

    International Nuclear Information System (INIS)

    Gottschalk, E.E.

    2001-01-01

    BTeV is a collider experiment that has been approved to run in the Tevatron at Fermilab. The experiment will conduct precision studies of CP violation using a forward-geometry detector. The detector will be optimized for high-rate detection of beauty and charm particles produced in collisions between protons and anti-protons. BTeV will trigger on beauty and charm events by taking advantage of the main difference between these heavy quark events and more typical hadronic events - the presence of detached beauty and charm decay vertices. The first stage of the BTeV trigger will receive data from a pixel vertex detector at a rate of 100 gb s -1 , reconstruct tracks and vertices for every beam crossing, reject 99% of beam crossings that do not produce beauty or charm particles, and trigger on beauty events with high efficiency. An overview of the trigger design and its influence on the design of the pixel vertex detector is presented

  2. Event reconstruction algorithms for the ATLAS trigger

    Energy Technology Data Exchange (ETDEWEB)

    F-Martin, T; Avolio, G; Backlund, S [European Laboratory for Particle Physics (CERN), Geneva (Switzerland); Abolins, M [Michigan State University, Department of Physics and Astronomy, East Lansing, Michigan (United States); Adragna, P [Department of Physics, Queen Mary and Westfield College, University of London, London (United Kingdom); Aleksandrov, E; Aleksandrov, I [Joint Institute for Nuclear Research, Dubna (Russian Federation); Amorim, A [Laboratorio de Instrumentacao e Fisica Experimental, Lisboa (Portugal); Anderson, K [University of Chicago, Enrico Fermi Institute, Chicago, Illinois (United States); Anduaga, X [National University of La Plata, La Plata (United States); Aracena, I; Bartoldus, R [Stanford Linear Accelerator Center (SLAC), Stanford (United States); Asquith, L [Department of Physics and Astronomy, University College London, London (United Kingdom); Badescu, E [National Institute for Physics and Nuclear Engineering, Institute of Atomic Physics, Bucharest (Romania); Baines, J [Rutherford Appleton Laboratory, Chilton, Didcot (United Kingdom); Beck, H P [Laboratory for High Energy Physics, University of Bern, Bern (Switzerland); Bee, C [Centre de Physique des Particules de Marseille, IN2P3-CNRS, Marseille (France); Bell, P [Department of Physics and Astronomy, University of Manchester, Manchester (United Kingdom); Barria, P; Batreanu, S [and others

    2008-07-01

    The ATLAS experiment under construction at CERN is due to begin operation at the end of 2007. The detector will record the results of proton-proton collisions at a center-of-mass energy of 14 TeV. The trigger is a three-tier system designed to identify in real-time potentially interesting events that are then saved for detailed offline analysis. The trigger system will select approximately 200 Hz of potentially interesting events out of the 40 MHz bunch-crossing rate (with 10{sup 9} interactions per second at the nominal luminosity). Algorithms used in the trigger system to identify different event features of interest will be described, as well as their expected performance in terms of selection efficiency, background rejection and computation time per event. The talk will concentrate on recent improvements and on performance studies, using a very detailed simulation of the ATLAS detector and electronics chain that emulates the raw data as it will appear at the input to the trigger system.

  3. Event reconstruction algorithms for the ATLAS trigger

    International Nuclear Information System (INIS)

    F-Martin, T; Avolio, G; Backlund, S; Abolins, M; Adragna, P; Aleksandrov, E; Aleksandrov, I; Amorim, A; Anderson, K; Anduaga, X; Aracena, I; Bartoldus, R; Asquith, L; Badescu, E; Baines, J; Beck, H P; Bee, C; Bell, P; Barria, P; Batreanu, S

    2008-01-01

    The ATLAS experiment under construction at CERN is due to begin operation at the end of 2007. The detector will record the results of proton-proton collisions at a center-of-mass energy of 14 TeV. The trigger is a three-tier system designed to identify in real-time potentially interesting events that are then saved for detailed offline analysis. The trigger system will select approximately 200 Hz of potentially interesting events out of the 40 MHz bunch-crossing rate (with 10 9 interactions per second at the nominal luminosity). Algorithms used in the trigger system to identify different event features of interest will be described, as well as their expected performance in terms of selection efficiency, background rejection and computation time per event. The talk will concentrate on recent improvements and on performance studies, using a very detailed simulation of the ATLAS detector and electronics chain that emulates the raw data as it will appear at the input to the trigger system

  4. Full-scale physical model of landslide triggering

    Science.gov (United States)

    Lora, M.; Camporese, M.; Salandin, P.

    2013-12-01

    of our experiments is to reproduce the instability trigger that occurs in saturated or partially unsaturated conditions depending on the specific characteristics of the soil and its initial conditions; the retention curve of fine sand and the initial porosity are taken into account to highlight the hydrological condition of the surface layer during the trigger occurrence. Through our experimental setup we can investigate the succession of phases and their magnitude that cause the landslide trigger, in order to understand the instability mechanism that heavy rainfall can induce in fine sandy hillslopes. Particular attention is given on the role of water pressure head, not only with respect to the violation of Coulomb failure within a sloping soil, but also with respect to the subsequent deformation that involves the upper hillslope layers. In particular, we report here on the characterization of the sandy terrain used in the experiments and the preliminary results, together with a first discussion of the observed data.

  5. Extensive upper respiratory tract sarcoidosis

    Science.gov (United States)

    Soares, Mafalda Trindade; Sousa, Carolina; Garanito, Luísa; Freire, Filipe

    2016-01-01

    Sarcoidosis is a chronic granulomatous disease of unknown aetiology. It can affect any part of the organism, although the lung is the most frequently affected organ. Upper airway involvement is rare, particularly if isolated. Sarcoidosis is a diagnosis of exclusion, established by histological evidence of non-caseating granulomas and the absence of other granulomatous diseases. The authors report a case of a man with sarcoidosis manifesting as a chronic inflammatory stenotic condition of the upper respiratory tract and trachea. PMID:27090537

  6. The ATLAS online High Level Trigger framework experience reusing offline software components in the ATLAS trigger

    CERN Document Server

    Wiedenmann, W

    2009-01-01

    Event selection in the Atlas High Level Trigger is accomplished to a large extent by reusing software components and event selection algorithms developed and tested in an offline environment. Many of these offline software modules are not specifically designed to run in a heavily multi-threaded online data flow environment. The Atlas High Level Trigger (HLT) framework based on the Gaudi and Atlas Athena frameworks, forms the interface layer, which allows the execution of the HLT selection and monitoring code within the online run control and data flow software. While such an approach provides a unified environment for trigger event selection across all of Atlas, it also poses strict requirements on the reused software components in terms of performance, memory usage and stability. Experience of running the HLT selection software in the different environments and especially on large multi-node trigger farms has been gained in several commissioning periods using preloaded Monte Carlo events, in data taking peri...

  7. The ATLAS High Level Trigger Steering Framework and the Trigger 
Configuration System.

    CERN Document Server

    Pérez Cavalcanti, Tiago; The ATLAS collaboration

    2011-01-01

    The ATLAS High Level Trigger Steering Framework and the Trigger 
Configuration System.
 
The ATLAS detector system installed in the Large Hadron Collider (LHC) 
at CERN is designed to study proton-proton and nucleus-nucleus 
collisions with a maximum center of mass energy of 14 TeV at a bunch 
collision rate of 40MHz.  In March 2010 the four LHC experiments saw 
the first proton-proton collisions at 7 TeV. Still within the year a 
collision rate of nearly 10 MHz is expected. At ATLAS, events of 
potential interest for ATLAS physics are selected by a three-level 
trigger system, with a final recording rate of about 200 Hz. The first 
level (L1) is implemented in custom hardware; the two levels of 
the high level trigger (HLT) are software triggers, running on large 
farms of standard computers and network devices. 

Within the ATLAS physics program more than 500 trigger signatures are 
defined. The HLT tests each signature on each L1-accepted event; the 
test outcome is recor...

  8. Upper secondary students’ situational interest:

    DEFF Research Database (Denmark)

    Dohn, Niels Bonderup

    2013-01-01

    ’ interest was investigated by a descriptive interpretive approach, based on data from classroom and field trip observations, video recording, and interviews. The findings provided evidence that substantial situational interest can be generated during a fieldtrip to a zoo. Students’ interest was triggered...

  9. Multi-Agent System based Event-Triggered Hybrid Controls for High-Security Hybrid Energy Generation Systems

    DEFF Research Database (Denmark)

    Dou, Chun-Xia; Yue, Dong; Guerrero, Josep M.

    2017-01-01

    This paper proposes multi-agent system based event- triggered hybrid controls for guaranteeing energy supply of a hybrid energy generation system with high security. First, a mul-ti-agent system is constituted by an upper-level central coordi-nated control agent combined with several lower......-level unit agents. Each lower-level unit agent is responsible for dealing with internal switching control and distributed dynamic regula-tion for its unit system. The upper-level agent implements coor-dinated switching control to guarantee the power supply of over-all system with high security. The internal...

  10. Machine learning techniques for razor triggers

    CERN Document Server

    Kolosova, Marina

    2015-01-01

    My project was focused on the development of a neural network which can predict if an event passes or not a razor trigger. Using synthetic data containing jets and missing transverse energy we built and trained a razor network by supervised learning. We accomplished a ∼ 91% agreement between the output of the neural network and the target while the other 10% was due to the noise of the neural network. We could apply such networks during the L1 trigger using neuromorhic hardware. Neuromorphic chips are electronic systems that function in a way similar to an actual brain, they are faster than GPUs or CPUs, but they can only be used with spiking neural networks.

  11. Exogenously triggered response inhibition in developmental stuttering.

    Science.gov (United States)

    Eggers, Kurt; De Nil, Luc F; Van den Bergh, Bea R H

    2018-06-01

    The purpose of the present study was to examine relations between children's exogenously triggered response inhibition and stuttering. Participants were 18 children who stutter (CWS; mean age = 9;01 years) and 18 children who not stutter (CWNS; mean age = 9;01 years). Participants were matched on age (±3 months) and gender. Response inhibition was assessed by a stop signal task (Verbruggen, Logan, & Stevens, 2008). Results suggest that CWS, compared to CWNS, perform comparable to CWNS in a task where response control is externally triggered. Our findings seem to indicate that previous questionnaire-based findings (Eggers, De Nil, & Van den Bergh, 2010) of a decreased efficiency of response inhibition cannot be generalized to all types of response inhibition. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. The ALICE Central Trigger Processor (CTP) upgrade

    International Nuclear Information System (INIS)

    Krivda, M.; Alexandre, D.; Barnby, L.S.; Evans, D.; Jones, P.G.; Jusko, A.; Lietava, R.; Baillie, O. Villalobos; Pospíšil, J.

    2016-01-01

    The ALICE Central Trigger Processor (CTP) at the CERN LHC has been upgraded for LHC Run 2, to improve the Transition Radiation Detector (TRD) data-taking efficiency and to improve the physics performance of ALICE. There is a new additional CTP interaction record sent using a new second Detector Data Link (DDL), a 2 GB DDR3 memory and an extension of functionality for classes. The CTP switch has been incorporated directly onto the new LM0 board. A design proposal for an ALICE CTP upgrade for LHC Run 3 is also presented. Part of the development is a low latency high bandwidth interface whose purpose is to minimize an overall trigger latency

  13. CDF tau triggers, analysis and other developments

    International Nuclear Information System (INIS)

    J. R. Smith

    2003-01-01

    This note is a write-up of contribution made by the author to the HCP2002 conference. It has two principal subjects. The first subject concerns the CDF τ triggers, τ-cone algorithms and τ physics analysis. τ physics is going to be very important in Run II because τ's can extend SUSY searches at large tan β in particular, τ's will help in the searches for (tilde χ) 1 ± (tilde χ) 2 0 , MSSM Higgs and other non Standard Model (SM) processes. Also, τ events are important for various Standard Model processes including Precision Electroweak, t(bar t), and SM Higgs searches. τ triggers are installed and operating at CDF. The second subject of this contribution to the HCP2002 conference concerns the algorithms of backwards differentiation abstracted from their usual setting inside of Automatic Differentiation software packages. Backwards differentiation (reverse-mode differentiation) provides a useful means for optimizing many kinds of problems

  14. Particle combinations in the LHCb Upgrade trigger

    CERN Document Server

    Zhao, Fanyi

    2017-01-01

    The LHCb experiment will be upgraded during long shutdown II (2018-2020) to process inelastic proton-proton collisions at 30MHz in a software application and run at a higher instantaneous luminosity of $2\\times 10^{33}cm^{−2}s^{−1}$. Each of these collisions will contain substantially more proton-proton interactions and charged particles. It is important to identify the decay vertices of heavy-flavour hadrons produced by the primary proton-proton interaction in an efficient, CPU-performant manner. In this project, I will learn about the LHCb trigger and experimental programme and investigate alternative models for reconstructing these vertices, which may scale more efficiently to the upgraded trigger conditions than the current model.

  15. The ATLAS Trigger Simulation with Legacy Software

    CERN Document Server

    Bernius, Catrin; The ATLAS collaboration

    2017-01-01

    Physics analyses at the LHC which search for rare physics processes or measure Standard Model parameters with high precision require accurate simulations of the detector response and the event selection processes. The accurate simulation of the trigger response is crucial for determination of overall selection efficiencies and signal sensitivities. For the generation and the reconstruction of simulated event data, generally the most recent software releases are used to ensure the best agreement between simulated data and real data. For the simulation of the trigger selection process, however, the same software release with which real data were taken should be ideally used. This requires potentially running with software dating many years back, the so-called legacy software. Therefore having a strategy for running legacy software in a modern environment becomes essential when data simulated for past years start to present a sizeable fraction of the total. The requirements and possibilities for such a simulatio...

  16. Software trigger for the TOPAZ detector at TRISTAN

    International Nuclear Information System (INIS)

    Tsukamoto, T.; Yamauchi, M.; Enomoto, R.

    1990-01-01

    A new software trigger system was developed and installed at the TOPAZ detector to the trigger system for the TRISTAN e + e - collider to take data efficiently in the scheduled high luminosity experiment. This software trigger requires two or more charged tracks originated at the interaction point by examining the timing of signals from the time projection chamber. To execute the vertex finding very quickly, four microprocessors are used in parallel. By this new trigger the rate of the track trigger was reduced down to 30-40% with very small inefficiency. The additional dead time by this trigger is negligible. (orig.)

  17. The CLEO-III Trigger: Decision and gating

    International Nuclear Information System (INIS)

    Bergfeld, T.J.; Gollin, G.D.; Haney, M.J.

    1996-01-01

    The CLEO-III Trigger provides a trigger decision every 42ns, with a latency of approximately 2.5μs. This paper describes the free-running, pipelined trigger decision logic, the throttling mechanism whereby the data acquisition system can modulate the trigger rate to maximize throughput without buffer overrun, and the subsequent signal distribution mechanism for delivering the trigger decision to the front-end electronics. This paper also describes the multilevel simulation methods employed to allow detailed low-level models of trigger components to be co-simulated with more abstract system models, thus allowing full system modeling without incurring prohibitive computational overheads

  18. VHF lightning mapping observations of a triggered lightning flash

    Science.gov (United States)

    Edens, H. E.; Eack, K. B.; Eastvedt, E. M.; Trueblood, J. J.; Winn, W. P.; Krehbiel, P. R.; Aulich, G. D.; Hunyady, S. J.; Murray, W. C.; Rison, W.; Behnke, S. A.; Thomas, R. J.

    2012-10-01

    On 3 August 2010 an extensive lightning flash was triggered over Langmuir Laboratory in New Mexico. The upward positive leader propagated into the storm's midlevel negative charge region, extending over a horizontal area of 13 × 13 km and 7.5 km altitude. The storm had a normal-polarity tripolar charge structure with upper positive charge over midlevel negative charge. Lightning Mapping Array (LMA) observations were used to estimate positive leader velocities along various branches, which were in the range of 1-3 × 104 m s-1, slower than in other studies. The upward positive leader initiated at 3.4 km altitude, but was mapped only above 4.0 km altitude after the onset of retrograde negative breakdown, indicating a change in leader propagation and VHF emissions. The observations suggest that both positive and negative breakdown produce VHF emissions that can be located by time-of-arrival systems, and that not all VHF emissions occurring along positive leader channels are associated with retrograde negative breakdown.

  19. Acute exposure to air pollution triggers atrial fibrillation.

    Science.gov (United States)

    Link, Mark S; Luttmann-Gibson, Heike; Schwartz, Joel; Mittleman, Murray A; Wessler, Benjamin; Gold, Diane R; Dockery, Douglas W; Laden, Francine

    2013-08-27

    This study sought to evaluate the association of air pollution with the onset of atrial fibrillation (AF). Air pollution in general and more specifically particulate matter has been associated with cardiovascular events. Although ventricular arrhythmias are traditionally thought to convey the increased cardiovascular risk, AF may also contribute. Patients with dual chamber implantable cardioverter-defibrillators (ICDs) were enrolled and followed prospectively. The association of AF onset with air quality including ambient particulate matter pollution between 2 and 48 h prior to the AF were examined. Of 176 patients followed for an average of 1.9 years, 49 patients had 328 episodes of AF lasting ≥ 30 s. Positive but nonsignificant associations were found for PM2.5 in the prior 24 h, but stronger associations were found with shorter exposure windows. The odds of AF increased by 26% (95% confidence interval: 8% to 47%) for each 6.0 μg/m(3) increase in PM2.5 in the 2 h prior to the event (p = 0.004). The odds of AF were highest at the upper quartile of mean PM2.5. PM was associated with increased odds of AF onset within hours following exposure in patients with known cardiac disease. Air pollution is an acute trigger of AF, likely contributing to the pollution-associated adverse cardiac outcomes observed in epidemiological studies. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. A multiplicity jump trigger using silicon planes

    International Nuclear Information System (INIS)

    Alexopoulos, T.; Erwin, A.R.

    1993-01-01

    Since silicon tracking planes are already present in a B decay experiment, it is an attractive idea to use these as part of a multiplicity jump detector. Two average B decays would produce a multiplicity jump of around 10 in the final state. Such a trigger has been tried for a fixed target Charm experiment with disappointing success. The failure was attributed to the difficulty in adequately controlling the gains of a large number of microstrip amplifies

  1. LHC detectors trigger/DAQ at LHC

    CERN Document Server

    Sphicas, Paris

    1998-01-01

    At its design luminosity, the LHC will deliver hundreds of millions of proton-proton interactions per second. Storage and computing limitations limit the number of physics events that can be recorded to about 100 per second. The selection will be carried out by the Trigger and data acquisition systems of the experiments. This lecture will review the requirements, architectures and various designs currently considered.

  2. A solar tornado triggered by flares?

    OpenAIRE

    Panesar, N. K.; Innes, D. E.; Tiwari, S. K.; Low, B. C.

    2013-01-01

    Context. Solar tornados are dynamical, conspicuously helical magnetic structures that are mainly observed as a prominence activity. Aims. We investigate and propose a triggering mechanism for the solar tornado observed in a prominence cavity by SDO/AIA on September 25, 2011. Methods. High-cadence EUV images from the SDO/AIA and the Ahead spacecraft of STEREO/EUVI are used to correlate three flares in the neighbouring active-region (NOAA 11303) and their EUV waves with the dynamical de...

  3. Storytelling as a trigger for sharing conversations

    OpenAIRE

    Emma Louise Parfitt

    2014-01-01

    This article explores whether traditional oral storytelling can be used to provide insights into the way in which young people of 12-14 years identify and understand the language of emotion and behaviour. Following the preliminary analysis, I propose that storytelling may trigger sharing conversations. My research attempts to extend the social and historical perspectives of Jack Zipes, on fairy tales, into a sociological analysis of young people’s lives today. I seek to investigate the extent...

  4. RF gun using laser-triggered photocathode

    International Nuclear Information System (INIS)

    Akiyama, H.; Otake, Y.; Naito, T.; Takeuchi, Y.; Yoshioka, M.

    1992-01-01

    An RF gun using laser-triggered photocathode has many advantages as an injector of the linear colliders since it can generate a low emittance and high current pulsed beam. The experimental facility for the RF gun, such as an RF system, a laser system and a photocathode have been fabricated to study the fundamental characteristics. The dynamics of the RF gun has also studied by the 1D sheet beam model. (author)

  5. Splint therapy for trigger finger in children.

    Science.gov (United States)

    Tsuyuguchi, Y; Tada, K; Kawaii, H

    1983-02-01

    During the last 9 years, 83 trigger digits in 65 children were treated using a modified coil spring splint which maintains the interphalangeal (IP) joint in neutral extension or hyperextension. Sixty-two digits (75%) were completely healed following splint therapy alone, after an average period of splinting for 9.4 months. Eight digits which did not improve with splinting were surgically treated. Splint therapy to maintain the IP joint in neutral extension or hyperextension proved markedly effective in our series.

  6. Earthquake-triggered landslides in southwest China

    OpenAIRE

    X. L. Chen; Q. Zhou; H. Ran; R. Dong

    2012-01-01

    Southwest China is located in the southeastern margin of the Tibetan Plateau and it is a region of high seismic activity. Historically, strong earthquakes that occurred here usually generated lots of landslides and brought destructive damages. This paper introduces several earthquake-triggered landslide events in this region and describes their characteristics. Also, the historical data of earthquakes with a magnitude of 7.0 or greater, having occurred in this region, is col...

  7. Diffraction in ALICE and trigger efficiencies

    CERN Document Server

    Navin, Sparsh; Lietava, Roman

    ALICE is built to measure the properties of strongly interacting matter created in heavy-ion collisions. In addition, taking advantage of the low pT acceptance in the central barrel, ALICE is playing an important role in understanding pp collisions with minimum bias triggers at LHC energies. The work presented in this thesis is based on pp data simulated by the ALICE collaboration and early data collected at a center-of-mass energy of 7 TeV. A procedure to calculate trigger efficiencies and an estimate of the systematic uncertainty due to the limited acceptance of the detector are shown. A kinematic comparison between Monte Carlo event generators, PYTHIA 6, PYTHIA 8 and PHOJET is also presented. To improve the description of diffraction in PYTHIA, a hard diffractive component was added to PYTHIA 8 in 2009, which is described. Finally a trigger with a high efficiency for picking diffractive events is used to select a sample with an enhanced diffractive component from pp data. These data are compared to Monte ...

  8. Trigger chemistries for better industrial formulations.

    Science.gov (United States)

    Wang, Hsuan-Chin; Zhang, Yanfeng; Possanza, Catherine M; Zimmerman, Steven C; Cheng, Jianjun; Moore, Jeffrey S; Harris, Keith; Katz, Joshua S

    2015-04-01

    In recent years, innovations and consumer demands have led to increasingly complex liquid formulations. These growing complexities have provided industrial players and their customers access to new markets through product differentiation, improved performance, and compatibility/stability with other products. One strategy for enabling more complex formulations is the use of active encapsulation. When encapsulation is employed, strategies are required to effect the release of the active at the desired location and time of action. One particular route that has received significant academic research effort is the employment of triggers to induce active release upon a specific stimulus, though little has translated for industrial use to date. To address emerging industrial formulation needs, in this review, we discuss areas of trigger release chemistries and their applications specifically as relevant to industrial use. We focus the discussion on the use of heat, light, shear, and pH triggers as applied in several model polymeric systems for inducing active release. The goal is that through this review trends will emerge for how technologies can be better developed to maximize their value through industrial adaptation.

  9. The ATLAS Level-2 Trigger Pilot Project

    CERN Document Server

    Wickens, F J

    2000-01-01

    The Level-2 Trigger Pilot Project of ATLAS, one of the two general purpose LHC experiments, is part of the on-going programme to develop the ATLAS High Level Triggers (HLT). The Level-2 Trigger will receive events at up to 100 kHz, which has to be reduced to a rate suitable for full event-building of the order of 1 kHz. To reduce the data collection bandwidth and processing power required for the challenging Level-2 task it is planned to use Region of Interest guidance (from Level-1) and sequential processing. The Pilot Project included the construction and use of testbeds of up to 48 processing nodes, development of optimised components and computer simulations of a full system. It has shown how the required performance can be achieved, using largely commodity components and operating systems, and validated an architecture for the Level-2 system. This paper describes the principal achievements and conclusions of this project. (28 refs).

  10. The ATLAS Level-2 Trigger Pilot Project

    CERN Document Server

    Blair, R; Haberichter, W N; Schlereth, J L; Bock, R; Bogaerts, A; Boosten, M; Dobinson, Robert W; Dobson, M; Ellis, Nick; Elsing, M; Giacomini, F; Knezo, E; Martin, B; Shears, T G; Tapprogge, Stefan; Werner, P; Hansen, J R; Wäänänen, A; Korcyl, K; Lokier, J; George, S; Green, B; Strong, J; Clarke, P; Cranfield, R; Crone, G J; Sherwood, P; Wheeler, S; Hughes-Jones, R E; Kolya, S; Mercer, D; Hinkelbein, C; Kornmesser, K; Kugel, A; Männer, R; Müller, M; Sessler, M; Simmler, H; Singpiel, H; Abolins, M; Ermoline, Y; González-Pineiro, B; Hauser, R; Pope, B; Sivoklokov, S Yu; Boterenbrood, H; Jansweijer, P; Kieft, G; Scholte, R; Slopsema, R; Vermeulen, J C; Baines, J T M; Belias, A; Botterill, David R; Middleton, R; Wickens, F J; Falciano, S; Bystrický, J; Calvet, D; Gachelin, O; Huet, M; Le Dû, P; Mandjavidze, I D; Levinson, L; González, S; Wiedenmann, W; Zobernig, H

    2002-01-01

    The Level-2 Trigger Pilot Project of ATLAS, one of the two general purpose LHC experiments, is part of the on-going program to develop the ATLAS high-level triggers (HLT). The Level-2 Trigger will receive events at up to 100 kHz, which has to be reduced to a rate suitable for full event-building of the order of 1 kHz. To reduce the data collection bandwidth and processing power required for the challenging Level-2 task it is planned to use Region of Interest guidance (from Level-1) and sequential processing. The Pilot Project included the construction and use of testbeds of up to 48 processing nodes, development of optimized components and computer simulations of a full system. It has shown how the required performance can be achieved, using largely commodity components and operating systems, and validated an architecture for the Level-2 system. This paper describes the principal achievements and conclusions of this project. (28 refs).

  11. The ALICE Dimuon Spectrometer High Level Trigger

    CERN Document Server

    Becker, B; Cicalo, Corrado; Das, Indranil; de Vaux, Gareth; Fearick, Roger; Lindenstruth, Volker; Marras, Davide; Sanyal, Abhijit; Siddhanta, Sabyasachi; Staley, Florent; Steinbeck, Timm; Szostak, Artur; Usai, Gianluca; Vilakazi, Zeblon

    2009-01-01

    The ALICE Dimuon Spectrometer High Level Trigger (dHLT) is an on-line processing stage whose primary function is to select interesting events that contain distinct physics signals from heavy resonance decays such as J/psi and Gamma particles, amidst unwanted background events. It forms part of the High Level Trigger of the ALICE experiment, whose goal is to reduce the large data rate of about 25 GB/s from the ALICE detectors by an order of magnitude, without loosing interesting physics events. The dHLT has been implemented as a software trigger within a high performance and fault tolerant data transportation framework, which is run on a large cluster of commodity compute nodes. To reach the required processing speeds, the system is built as a concurrent system with a hierarchy of processing steps. The main algorithms perform partial event reconstruction, starting with hit reconstruction on the level of the raw data received from the spectrometer. Then a tracking algorithm finds track candidates from the recon...

  12. Surgical Treatment of Trigger Finger: Open Release

    Directory of Open Access Journals (Sweden)

    Firat Ozan

    2016-01-01

    Full Text Available In this study, open A1 pulley release results were evaluated in patients with a trigger finger diagnosis. 45 patients (29 females, 16 males, mean age 50.7 ± 11.9; range (24-79, 45 trigger fingers were released via open surgical technique. On the 25 of 45 cases were involved in the right hand and 16 of them were at the thumb, 2 at index, 6 at the middle and 1 at ring finger. Similarly, at the left hand, 15 of 20 cases were at the thumb, 1 at the index finger, 2 at middle finger and 2 at ring finger. Average follow-up time was 10.2 ± 2.7 (range, 6-15 months. Comorbidities in patients were; diabetes mellitus at 6 cases (13.3%, hypertension at 11 cases (24.4%, hyperthyroidism at 2 cases (4.4%, dyslipidemia at 2 cases (4.4% and lastly 2 cases had carpal tunnel syndrome operation. The mean time between the onset of symptoms to surgery was 6.9 ± 4.8 (range, 2-24 months. Patient satisfaction was very good in 34 cases (75.4% and good in 11 (24.6% patients. The distance between the pulpa of the operated finger and the palm was normal in every case postoperatively. We have not encountered any postoperative complications. We can recommend that; A1 pulley release via open incision is an effective and reliable method in trigger finger surgery.

  13. CMS High Level Trigger Timing Measurements

    International Nuclear Information System (INIS)

    Richardson, Clint

    2015-01-01

    The two-level trigger system employed by CMS consists of the Level 1 (L1) Trigger, which is implemented using custom-built electronics, and the High Level Trigger (HLT), a farm of commercial CPUs running a streamlined version of the offline CMS reconstruction software. The operational L1 output rate of 100 kHz, together with the number of CPUs in the HLT farm, imposes a fundamental constraint on the amount of time available for the HLT to process events. Exceeding this limit impacts the experiment's ability to collect data efficiently. Hence, there is a critical need to characterize the performance of the HLT farm as well as the algorithms run prior to start up in order to ensure optimal data taking. Additional complications arise from the fact that the HLT farm consists of multiple generations of hardware and there can be subtleties in machine performance. We present our methods of measuring the timing performance of the CMS HLT, including the challenges of making such measurements. Results for the performance of various Intel Xeon architectures from 2009-2014 and different data taking scenarios are also presented. (paper)

  14. The Sandia transportable triggered lightning instrumentation facility

    Science.gov (United States)

    Schnetzer, George H.; Fisher, Richard J.

    1991-01-01

    Development of the Sandia Transportable Triggered Lightning Instrumentation Facility (SATTLIF) was motivated by a requirement for the in situ testing of a munitions storage bunker. Transfer functions relating the incident flash currents to voltages, currents, and electromagnetic field values throughout the structure will be obtained for use in refining and validating a lightning response computer model of this type of structure. A preliminary shakedown trial of the facility under actual operational conditions was performed during summer of 1990 at the Kennedy Space Center's (KSC) rocket-triggered lightning test site. A description is given of the SATTLIF, which is readily transportable on a single flatbed truck of by aircraft, and its instrumentation for measuring incident lightning channel currents and the responses of the systems under test. Measurements of return-stroke current peaks obtained with the SATTLIF are presented. Agreement with data acquired on the same flashes with existing KSC instrumentation is, on average, to within approximately 7 percent. Continuing currents were measured with a resolution of approximately 2.5 A. This field trial demonstrated the practicality of using a transportable triggered lightning facility for specialized test applications.

  15. Run-2 ATLAS Trigger and Detector Performance

    CERN Document Server

    Winklmeier, Frank; The ATLAS collaboration

    2016-01-01

    The 2nd LHC run has started in June 2015 with a pp centre-of-mass collision energy of 13 TeV, and ATLAS has taken first data at this new energy. In this talk the improvements made to the ATLAS experiment during the 2-year shutdown 2013/2014 will be discussed, and first detector and trigger performance results from the Run-2 will be shown. In general, reconstruction algorithms of tracks, e/gamma, muons, taus, jets and flavour tag- ging have been improved for Run-2. The new reconstruction algorithms and their performance measured using the data taken in 2015 at sqrt(s)=13 TeV will be discussed. Reconstruction efficiency, isolation performance, transverse momentum resolution and momentum scales are measured in various regions of the detector and in momentum intervals enlarged with respect to those measured in the Run-1. This presentation will also give an overview of the upgrades to the ATLAS trigger system that have been implemented during the LHC shutdown in order to deal with the increased trigger rates (fact...

  16. Oncoplastic Surgery for Upper/Upper Inner Quadrant Breast Cancer.

    Science.gov (United States)

    Lin, Joseph; Chen, Dar-Ren; Wang, Yu-Fen; Lai, Hung-Wen

    2016-01-01

    Tumors located in the upper/upper inner quadrant of the breast warrant more attention. A small lesion relative to the size of breast in this location may be resolved by performing a level I oncoplastic technique. However, a wide excision may significantly reduce the overall quality of the breast shape by distorting the visible breast line. From June 2012 to April 2015, 36 patients with breast cancer located in the upper/upper inner quadrant underwent breast-conservation surgery with matrix rotation mammoplasty. According to the size and location of the tumor relative to the nipple-areola complex, 11 patients underwent matrix rotation with periareolar de-epithelialization (donut group) and the other 25 underwent matrix rotation only (non-donut group). The cosmetic results were self-assessed by questionnaires. The average weights of the excised breast lumps in the donut and non-donut groups were 104.1 and 84.5 g, respectively. During the 3-year follow-up period, local recurrence was observed in one case and was managed with nipple-sparing mastectomy followed by breast reconstruction with prosthetic implants. In total, 31 patients (88.6%) ranked their postoperative result as either acceptable or satisfactory. The treated breasts were also self-evaluated by 27 patients (77.1%) to be nearly identical to or just slightly different from the untreated side. Matrix rotation is an easy breast-preserving technique for treating breast cancer located in the upper/upper inner quadrant of the breast that requires a relatively wide excision. With this technique, a larger breast tumor could be removed without compromising the breast appearance.

  17. Oncoplastic Surgery for Upper/Upper Inner Quadrant Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Joseph Lin

    Full Text Available Tumors located in the upper/upper inner quadrant of the breast warrant more attention. A small lesion relative to the size of breast in this location may be resolved by performing a level I oncoplastic technique. However, a wide excision may significantly reduce the overall quality of the breast shape by distorting the visible breast line. From June 2012 to April 2015, 36 patients with breast cancer located in the upper/upper inner quadrant underwent breast-conservation surgery with matrix rotation mammoplasty. According to the size and location of the tumor relative to the nipple-areola complex, 11 patients underwent matrix rotation with periareolar de-epithelialization (donut group and the other 25 underwent matrix rotation only (non-donut group. The cosmetic results were self-assessed by questionnaires. The average weights of the excised breast lumps in the donut and non-donut groups were 104.1 and 84.5 g, respectively. During the 3-year follow-up period, local recurrence was observed in one case and was managed with nipple-sparing mastectomy followed by breast reconstruction with prosthetic implants. In total, 31 patients (88.6% ranked their postoperative result as either acceptable or satisfactory. The treated breasts were also self-evaluated by 27 patients (77.1% to be nearly identical to or just slightly different from the untreated side. Matrix rotation is an easy breast-preserving technique for treating breast cancer located in the upper/upper inner quadrant of the breast that requires a relatively wide excision. With this technique, a larger breast tumor could be removed without compromising the breast appearance.

  18. The ATLAS Trigger: Recent Experience and Future Plans

    CERN Document Server

    The ATLAS collaboration

    2009-01-01

    This paper will give an overview of the ATLAS trigger design and its innovative features. It will describe the valuable experience gained in running the trigger reconstruction and event selection in the fastchanging environment of the detector commissioning during 2008. It will also include a description of the trigger selection menu and its 2009 deployment plan from first collisions to the nominal luminosity. ATLAS is one of the two general-purpose detectors at the Large Hadron Collider (LHC). The trigger system needs to efficiently reject a large rate of background events and still select potentially interesting ones with high efficiency. After a first level trigger implemented in custom electronics, the trigger event selection is made by the High Level Trigger (HLT) system, implemented in software. To reduce the processing time to manageable levels, the HLT uses seeded, step-wise and fast selection algorithms, aiming at the earliest possible rejection of background events. The ATLAS trigger event selection...

  19. Readout and triggering of the Soudan 2 nucleon decay experiment

    International Nuclear Information System (INIS)

    Thron, J.L.

    1984-01-01

    The readout and triggering electronics for the Soudan 2 proton decay detector is presented. Pratically all the electronics is implemented in CMOS. The triggering scheme is highly flexible and software controllable

  20. Cross-Lingual Lexical Triggers in Statistical Language Modeling

    National Research Council Canada - National Science Library

    Kim, Woosung; Khudanpur, Sanjeev

    2003-01-01

    .... We achieve this through an extension of the method of lexical triggers to the cross-language problem, and by developing a likelihoodbased adaptation scheme for combining a trigger model with an N-gram model...

  1. 77 FR 38033 - WTO Agricultural Safeguard Trigger Levels

    Science.gov (United States)

    2012-06-26

    ... DEPARTMENT OF AGRICULTURE Foreign Agricultural Service WTO Agricultural Safeguard Trigger Levels... and trigger levels for safeguard measures provided for in the World Trade Organization (WTO) Agreement... measures under the safeguard provisions of the WTO [[Page 38034

  2. Trigger Algorithms and Electronics for the ATLAS Muon NSW Upgrade

    CERN Document Server

    Guan, Liang; The ATLAS collaboration

    2015-01-01

    The ATLAS New Small Wheel (NSW), comprising MicroMegas (MMs) and small-strip Thin Gap Chambers (sTGCs), will upgrade the ATLAS muon system for a high background environment. Particularly, the NSW trigger will reduce the rate of fake triggers coming from background tracks in the endcap. We will present an overview of the FPGA-based trigger processor for NSW and trigger algorithms for sTGC and Micromegas detector sub systems. In additional, we will present development of NSW trigger electronics, in particular, the sTGC Trigger Data Serializer (TDS) ASIC, sTGC Pad Trigger board, the sTGC data packet router and L1 Data Driver Card. Finally, we will detail the challenges of meeting the low latency requirements of the trigger system and coping with the high background rates of the HL-LHC.

  3. Upper atmosphere research at INPE

    International Nuclear Information System (INIS)

    Clemesha, B.R.

    1984-01-01

    Upper atmosphere research at INPE is mainly concerned with the chemistry and dynamics of the stratosphere, upper mesosphere and lower thermosphere, and the middle thermosphere. Experimental work includes lidar observations of the stratospheric aerosol, measurements of stratospheric ozone by Dobson spectrophotometers and by balloon and rocket-borne sondes, lidar measurements of atmospheric sodium, and photometric observations of O, O 2 , OH and Na emissions, including interferrometric measurements of the OI6300 emission for the purpose of determing thermospheric winds and temperature. The airglow observations also include measurements of a number of emissions produced by the precipitation of energetic neutral particles generated by charge exchange in the ring current. Some recent results of INPE's upper atmosphere program are presented. (Author) [pt

  4. Discrete element modeling of triggered slip in faults with granular gouge: application to dynamic earthquake triggering

    International Nuclear Information System (INIS)

    Ferdowsi, B.

    2014-01-01

    Recent seismological observations based on new, more sensitive instrumentation show that seismic waves radiated from large earthquakes can trigger other earthquakes globally. This phenomenon is called dynamic earthquake triggering and is well-documented for over 30 of the largest earthquakes worldwide. Granular materials are at the core of mature earthquake faults and play a key role in fault triggering by exhibiting a rich nonlinear response to external perturbations. The stick-slip dynamics in sheared granular layers is analogous to the seismic cycle for earthquake fault systems. In this research effort, we characterize the macroscopic scale statistics and the grain-scale mechanisms of triggered slip in sheared granular layers. We model the granular fault gouge using three dimensional discrete element method simulations. The modeled granular system is put into stick-slip dynamics by applying a conning pressure and a shear load. The dynamic triggering is simulated by perturbing the spontaneous stick-slip dynamics using an external vibration applied to the boundary of the layer. The influences of the triggering consist in a frictional weakening during the vibration interval, a clock advance of the next expected large slip event and long term effects in the form of suppression and recovery of the energy released from the granular layer. Our study suggests that above a critical amplitude, vibration causes a significant clock advance of large slip events. We link this clock advance to a major decline in the slipping contact ratio as well as a decrease in shear modulus and weakening of the granular gouge layer. We also observe that shear vibration is less effective in perturbing the stick-slip dynamics of the granular layer. Our study suggests that in order to have an effective triggering, the input vibration must also explore the granular layer at length scales about or less than the average grain size. The energy suppression and the subsequent recovery and increased

  5. Toward a rational understanding of migraine trigger factors.

    Science.gov (United States)

    Martin, V T; Behbehani, M M

    2001-07-01

    The typical migraine patient is exposed to a myriad of migraine triggers on a daily basis. These triggers potentially can act at various sites within the cerebral vasculature and the central nervous system to promote the development of migraine headache. The challenge to the physician is in the identification and avoidance of migraine trigger factors within patients suffering from migraine headache. Only through a rational approach to migraine trigger factors can physicians develop an appropriate treatment strategy for migraine patients.

  6. The ATLAS online High Level Trigger framework: Experience reusing offline software components in the ATLAS trigger

    International Nuclear Information System (INIS)

    Wiedenmann, Werner

    2010-01-01

    Event selection in the ATLAS High Level Trigger is accomplished to a large extent by reusing software components and event selection algorithms developed and tested in an offline environment. Many of these offline software modules are not specifically designed to run in a heavily multi-threaded online data flow environment. The ATLAS High Level Trigger (HLT) framework based on the GAUDI and ATLAS ATHENA frameworks, forms the interface layer, which allows the execution of the HLT selection and monitoring code within the online run control and data flow software. While such an approach provides a unified environment for trigger event selection across all of ATLAS, it also poses strict requirements on the reused software components in terms of performance, memory usage and stability. Experience of running the HLT selection software in the different environments and especially on large multi-node trigger farms has been gained in several commissioning periods using preloaded Monte Carlo events, in data taking periods with cosmic events and in a short period with proton beams from LHC. The contribution discusses the architectural aspects of the HLT framework, its performance and its software environment within the ATLAS computing, trigger and data flow projects. Emphasis is also put on the architectural implications for the software by the use of multi-core processors in the computing farms and the experiences gained with multi-threading and multi-process technologies.

  7. New shower maximum trigger for electrons and photons at CDF

    International Nuclear Information System (INIS)

    Amidei, D.; Burkett, K.; Gerdes, D.; Miao, C.; Wolinski, D.

    1994-01-01

    For the 1994 Tevatron collider run, CDF has upgraded the electron and photo trigger hardware to make use of shower position and size information from the central shower maximum detector. For electrons, the upgrade has resulted in a 50% reduction in backgrounds while retaining approximately 90% of the signal. The new trigger also eliminates the background to photon triggers from single-phototube spikes

  8. New shower maximum trigger for electrons and photons at CDF

    International Nuclear Information System (INIS)

    Gerdes, D.

    1994-08-01

    For the 1994 Tevatron collider run, CDF has upgraded the electron and photon trigger hardware to make use of shower position and size information from the central shower maximum detector. For electrons, the upgrade has resulted in a 50% reduction in backgrounds while retaining approximately 90% of the signal. The new trigger also eliminates the background to photon triggers from single-phototube discharge

  9. Trigger Warnings as Respect for Student Boundaries in University Classrooms

    Science.gov (United States)

    Spencer, Leland G.; Kulbaga, Theresa A.

    2018-01-01

    The fierce public and scholarly debate over trigger warnings in university classrooms has often characterized the issue as one of academic freedom and ignored the social justice arguments for trigger warnings. In this essay, we argue that trigger warnings expand academic speech by engaging students more fully in their own learning. Specifically,…

  10. Triggering of Suicidal Erythrocyte Death by Regorafenib

    Directory of Open Access Journals (Sweden)

    Jens Zierle

    2016-01-01

    Full Text Available Background/Aims: The multikinase inhibitor regorafenib is utilized for the treatment of malignancy. The substance is effective in part by triggering suicidal death or apoptosis of tumor cells. Side effects of regorafenib include anemia. At least in theory, regorafenib induced anemia could result from stimulated suicidal erythrocyte death or eryptosis, characterized by cell shrinkage and cell membrane scrambling with phosphatidylserine translocation to the erythrocyte surface. Triggers of eryptosis include increase of cytosolic Ca2+ activity ([Ca2+]i, oxidative stress and ceramide. The present study explored, whether regorafenib induces eryptosis and, if so, whether it is effective up- and/or downstream of Ca2+. Methods: To this end, phosphatidylserine exposure at the cell surface was estimated from annexin-V-binding, cell volume from forward scatter, [Ca2+]i from Fluo3-fluorescence, ROS formation from DCFDA dependent fluorescence, and ceramide abundance utilizing specific antibodies. Results: A 48 hours exposure of human erythrocytes to regorafenib (≥ 0.5 µg/ml significantly increased the percentage of annexin-V-binding cells, significantly decreased forward scatter (≥ 1.25 µg/ml, but did not significantly increase Fluo3-fluorescence, DCFDA fluorescence or ceramide abundance. The effect of regorafenib on annexin-V-binding and forward scatter was not significantly blunted by removal of extracellular Ca2+. Regorafenib (5 µg/ml significantly augmented the increase of annexin-V-binding, but significantly blunted the decrease of forward scatter following treatment with the Ca2+ ionophore ionomycin. Conclusions: Regorafenib triggers cell shrinkage and phospholipid scrambling of the erythrocyte cell membrane, an effect at least in part downstream of Ca2+.

  11. Triggering of Suicidal Erythrocyte Death by Regorafenib.

    Science.gov (United States)

    Zierle, Jens; Bissinger, Rosi; Bouguerra, Ghada; Abbès, Salem; Lang, Florian

    2016-01-01

    The multikinase inhibitor regorafenib is utilized for the treatment of malignancy. The substance is effective in part by triggering suicidal death or apoptosis of tumor cells. Side effects of regorafenib include anemia. At least in theory, regorafenib induced anemia could result from stimulated suicidal erythrocyte death or eryptosis, characterized by cell shrinkage and cell membrane scrambling with phosphatidylserine translocation to the erythrocyte surface. Triggers of eryptosis include increase of cytosolic Ca2+ activity ([Ca2+]i), oxidative stress and ceramide. The present study explored, whether regorafenib induces eryptosis and, if so, whether it is effective up- and/or downstream of Ca2+. To this end, phosphatidylserine exposure at the cell surface was estimated from annexin-V-binding, cell volume from forward scatter, [Ca2+]i from Fluo3-fluorescence, ROS formation from DCFDA dependent fluorescence, and ceramide abundance utilizing specific antibodies. A 48 hours exposure of human erythrocytes to regorafenib (≥ 0.5 µg/ml) significantly increased the percentage of annexin-V-binding cells, significantly decreased forward scatter (≥ 1.25 µg/ml), but did not significantly increase Fluo3-fluorescence, DCFDA fluorescence or ceramide abundance. The effect of regorafenib on annexin-V-binding and forward scatter was not significantly blunted by removal of extracellular Ca2+. Regorafenib (5 µg/ml) significantly augmented the increase of annexin-V-binding, but significantly blunted the decrease of forward scatter following treatment with the Ca2+ ionophore ionomycin. Regorafenib triggers cell shrinkage and phospholipid scrambling of the erythrocyte cell membrane, an effect at least in part downstream of Ca2+. © 2016 The Author(s) Published by S. Karger AG, Basel.

  12. Selenium in the upper Blackfoot River watershed, southeastern Idaho, 2001-12

    Science.gov (United States)

    Mebane, Christopher A.; Mladenka, Greg; Van Every, Lynn; Williams, Marshall L.; Hardy, Mark A.; Garbarino, John R.

    2014-11-05

    The upper Blackfoot River in southeastern Idaho receives runoff from 12 large phosphate mines. Waste shales that are removed to access the phosphate ore are highly enriched with selenium, resulting in elevated selenium in runoff from the mine waste dumps. In 2001, in cooperation with the Bureau of Land Management, the U.S. Geological Survey (USGS) began monitoring streamflow, selenium, and other water-quality parameters at a single location near the outlet of the upper Blackfoot River to the Blackfoot Reservoir. Water samples primarily were collected by a flow triggered, automated pump sampler, supplemented by manual point and equal-width integrated manual samples.

  13. Euro Membership as a Real Option Trigger

    DEFF Research Database (Denmark)

    Aabo, Tom; Pantzalis, Christos

    2007-01-01

    -adopters (UK, Sweden, and Denmark) to exercise various forms of real options such as to establish alliances / partnerships, to enter new markets / market segments, to switch suppliers, and to generally expand in the Euro-area. The study furthermore shows that small, profitable and financially constrained firms...... are particularly likely to exercise such real options triggered by the introduction of the Euro. The results go beyond the immediate trade effects, which empirical studies have shown to be weak and without trade diversion as to the three non-adopters, and provide important insights about the potential long...

  14. Inflammation: a trigger for acute coronary syndrome

    International Nuclear Information System (INIS)

    SAGER, Hendrik B.; NAHRENDORF, Matthias

    2016-01-01

    Atherosclerosis is a chronic inflammatory disease of the vessel wall and a major cause of death worldwide. One of atherosclerosis’ most dreadful complications are acute coronary syndromes that comprise ST-segment elevation myocardial infarction, non-ST-segment elevation myocardial infarction, and unstable angina. We now understand that inflammation substantially contributes to the initiation, progression, and destabilization of atherosclerosis. In this review, we will focus on the role of inflammatory leukocytes, which are the cellular protagonists of vascular inflammation, in triggering disease progression and, ultimately, the destabilization that causes acute coronary syndromes.

  15. Pulsed laser triggered high speed microfluidic switch

    Science.gov (United States)

    Wu, Ting-Hsiang; Gao, Lanyu; Chen, Yue; Wei, Kenneth; Chiou, Pei-Yu

    2008-10-01

    We report a high-speed microfluidic switch capable of achieving a switching time of 10 μs. The switching mechanism is realized by exciting dynamic vapor bubbles with focused laser pulses in a microfluidic polydimethylsiloxane (PDMS) channel. The bubble expansion deforms the elastic PDMS channel wall and squeezes the adjacent sample channel to control its fluid and particle flows as captured by the time-resolved imaging system. A switching of polystyrene microspheres in a Y-shaped channel has also been demonstrated. This ultrafast laser triggered switching mechanism has the potential to advance the sorting speed of state-of-the-art microscale fluorescence activated cell sorting devices.

  16. Simple multifunction discriminator for multichannel triggers

    International Nuclear Information System (INIS)

    Maier, M.R.

    1982-10-01

    A simple version of a multifunction timing discriminator using only two integrated circuits is presented. It can be configured as a leading edge, a constant fraction, a zero cross or a dual threshold timing discriminator. Since so few parts are used, it is well suited for building multichannel timing discriminators. Two versions of this circuit are described: a quadruple multifunction discriminator and an octal constant fraction trigger. The different compromises made in these units are discussed. Results for walk and jitter obtained with these are presented and possible improvements are disussed

  17. EMIC triggered chorus emissions in Cluster data

    Czech Academy of Sciences Publication Activity Database

    Grison, Benjamin; Santolík, Ondřej; Cornilleau-Wehrlin, N.; Masson, A.; Engebretson, M. J.; Pickett, J. S.; Omura, Y.; Robert, P.; Nomura, R.

    2013-01-01

    Roč. 118, č. 3 (2013), s. 1159-1169 ISSN 2169-9380 R&D Projects: GA MŠk 7E12026; GA ČR(CZ) GPP209/11/P848; GA ČR GAP205/10/2279; GA MŠk(CZ) LH11122 EU Projects: European Commission(XE) 284520 - MAARBLE Program:FP7 Institutional support: RVO:68378289 Keywords : EMIC wave * triggered emission * plasmapause Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.440, year: 2013 http://onlinelibrary.wiley.com/doi/10.1002/jgra.50178/abstract

  18. New methods for trigger electronics development

    Energy Technology Data Exchange (ETDEWEB)

    Cleland, W.E.; Stern, E.G. [Univ. of Pittsburgh, PA (United States)

    1991-12-31

    The large and complex nature of RHIC experiments and the tight time schedule for their construction requires that new techniques for designing the electronics should be employed. This is particularly true of the trigger and data acquisition electronics which has to be ready for turn-on of the experiment. We describe the use of the Workview package from VIEWlogic Inc. for design, simulation, and verification of a flash ADC readout system. We also show how field-programmable gate arrays such as the Xilinx 4000 might be employed to construct or prototype circuits with a large number of gates while preserving flexibility.

  19. Steam explosion triggering and efficiency studies

    International Nuclear Information System (INIS)

    Buxton, L.D.; Nelson, L.S.; Benedick, W.B.

    1979-01-01

    A program at Sandia Laboratories to provide relevant data on the interaction of molten LWR core materials with water is described. Two different subtasks were established. The first was the performance of laboratory-scale experiments to investigate the ability to trigger steam explosions for realistic LWR core melt simulants under a wide range of initial conditions. The second was the performance of field-scale experiments to investigate the efficiency of converting the thermal energy of the melt into mechanical work in much larger steam explosions

  20. Use of parallel counters for triggering

    International Nuclear Information System (INIS)

    Nikityuk, N.M.

    1991-01-01

    Results of investigation of using parallel counters, majority coincidence schemes, parallel compressors for triggering in multichannel high energy spectrometers are described. Concrete examples of methods of constructing fast and economic new devices used to determine multiplicity hits t>900 registered in a hodoscopic plane and a pixel detector are given. For this purpose the author uses the syndrome coding method and cellular arrays. In addition, an effective coding matrix has been created which can be used for light signal coding. For example, such signals are supplied from scintillators to photomultipliers. 23 refs.; 21 figs

  1. Excimer lamp pumped by a triggered discharge

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, G.; Bollanti, S.; Di Lazzaro, P.; Flora, F.; Giordano, G.; Letardi, T.; Renieri, A.; Schina, G. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dip. Innovazione; Clementi, G.; Muzzi, F.; Zheng, C.E. [EL.EN. (Electronic Engineering), Florence (Italy)

    1996-11-01

    Radiation characteristics and discharge performances of an excimer lamp are described. The discharge of the HCl/Xe gas mixture at an atmospheric pressure, occurring near the quartz tube wall, is initiated by a trigger wire. A maximum total UV energy of about 0.4 J in a (0.8-0.9) {mu}s pulse, radiated from a 10 cm discharge length, is obtained with a total discharge input energy of 8 J. Excimer lamps are the preferred choice for medical and material processing irradiations, when the monochromaticity or coherence of UV light is not required, due to their low cost, reliability and easy maintenance.

  2. Data analysis at the CMS level-1 trigger: migrating complex selection algorithms from offline analysis and high-level trigger to the trigger electronics

    CERN Document Server

    Wulz, Claudia

    2017-01-01

    With ever increasing luminosity at the LHC, optimum online data selection is becoming more and more important. While in the case of some experiments (LHCb and ALICE) this task is being completely transferred to computer farms, the others -- ATLAS and CMS -- will not be able to do this in the medium-term future for technological, detector-related reasons. Therefore, these experiments pursue the complementary approach of migrating more and more of the offline and high-level trigger intelligence into the trigger electronics. The presentation illustrates how the level-1 trigger of the CMS experiment and in particular its concluding stage, the so-called ``Global Trigger", take up this challenge.

  3. Angiography of the upper extremity

    International Nuclear Information System (INIS)

    Janevski, B.K.

    1982-01-01

    This thesis provides a description of the technical and medical aspects of arteriography of the upper extremity and an extensive analysis of the angiographic anatomy and pathology of 750 selective studies performed in more than 500 patients. A short historical review is provided of angiography as a whole and of arteriography of the hand in particular. The method of percutaneous transfemoral catheterization of the arteries of the upper extremity and particularly the arteries of the hand is considered, discussing the problems the angiographer encounters frequently, describing the angiographic complications which may occur and emphasizing the measures to keep them to a minimum. The use of vasodilators in hand angiography is discussed. A short description of the embryological patterns persisting in the arteries of the arm is included in order to understand the congenital variations of the arteries of the upper extremity. The angiographic patterns and clinical aspects of the most common pathological processes involving the arteries of the upper extremities are presented. Special attention is paid to the correlation between angiography and pathology. (Auth.)

  4. Approach to upper gastrointestinal bleeding

    African Journals Online (AJOL)

    Upper gastrointestinal haemorrhage has a variety of causes (Table 1) and is the commonest complication of peptic ulceration and portal hypertension. Peptic ulceration in the duo- denum or stomach and oesophageal varices are the conditions most often responsible for patients who have the potential to present.

  5. Horizontal Diplopia Following Upper Blepharoplasty

    Directory of Open Access Journals (Sweden)

    Tomás Ortiz-Basso

    2014-09-01

    Full Text Available Diplopia is an infrequent complication after blepharoplasty. Most of the cases are in its vertical form due to trauma of the extraocular muscles. In this article, we present a case of horizontal diplopia following cosmetic upper blepharoplasty; we review the literature on this unexpected complication and offer some recommendations to avoid it.

  6. SQL Triggers Reacting on Time Events: An Extension Proposal

    Science.gov (United States)

    Behrend, Andreas; Dorau, Christian; Manthey, Rainer

    Being able to activate triggers at timepoints reached or after time intervals elapsed has been acknowledged by many authors as a valuable functionality of a DBMS. Recently, the interest in time-based triggers has been renewed in the context of data stream monitoring. However, up till now SQL triggers react to data changes only, even though research proposals and prototypes have been supporting several other event types, in particular time-based ones, since long. We therefore propose a seamless extension of the SQL trigger concept by time-based triggers, focussing on semantic issues arising from such an extension.

  7. The LHCb vertex locator and level-1 trigger

    CERN Document Server

    Dijkstra, H

    2000-01-01

    LHCb will study CP violation and other rare phenomena in B-decays with a forward detector at the LHC. One of the challenges is to design a fast and efficient trigger. The design of the silicon Vertex Locator (VELO) has been driven by the requirements of one of the most selective triggers of the experiment. The VELO trigger is designed to work at an input rate of 1 MHz. The requirements and implementation of the VELO and the associated trigger are summarised, followed by a description of an upgrade which improves the trigger performance significantly. (3 refs).

  8. Scintillation trigger system of the liquid argon neutrino detector

    International Nuclear Information System (INIS)

    Belikov, S.V.; Gurzhiev, S.N.; Gutnikov, Yu.E.; Denisov, A.G.; Kochetkov, V.I.; Matveev, M.Yu.; Mel'nikov, E.A.; Usachev, A.P.

    1994-01-01

    This paper presents the organization of the Scintillation Trigger System (STS) for the Liquid Argon Neutrino Detector of the Tagged Neutrino Facility. STS is aimed at the effective registration of the needed neutrino interaction type and production of a fast trigger signal with high time resolution. The fast analysis system of analog signal from the trigger scintillation planes for rejection of the trigger signals from background processes is described. Real scintillation trigger planes characteristics obtained on the basis of the presented data acquisition system are shown. 10 refs., 12 figs., 3 tabs

  9. PERFORMANCE OF THE ATLAS JET TRIGGER AND FUTURE DEVELOPMENTS

    CERN Document Server

    Sherafati, Nima; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment at the LHC uses a two-level trigger system to record interesting events maintaining good signal efficiency at lower energies where pileup dominates. A new challenge is to control the increased trigger rate due to the expected higher pileup for LHC Run 2. This poster presents the jet trigger efficiency as a function of the offline jet transverse momentum for proton-proton collision data at the centre-of-mass energy of 13 TeV. In addition, the efficiencies of global sequential calibrated (GSC) jet trigger, trimmed jet and trimmed dijet triggers are shown.

  10. Simulation of the ATLAS New Small Wheel Trigger Sysmtem

    CERN Document Server

    Saito, Tomoyuki; The ATLAS collaboration

    2017-01-01

    The instantaneous luminosity of the Large Hadron Collider (LHC) at CERN will be increased up to a factor of five with respect to the original design value to explore higher energy scale. In order to benefit from the expected high luminosity performance, the first station of the ATLAS muon end-cap Small Wheel system will be replaced by a New Small Wheel (NSW) detector. The NSW provide precise track segment information to the muon Level-1 trigger to reduce fake triggers. This contribution will summarize a detail of the NSW trigger decision system, track reconstruction algorithm implemented into the trigger processor and results of performance studies on the trigger system.

  11. Feasibility studies of a Level-1 Tracking Trigger for ATLAS

    CERN Document Server

    Warren, M; Brenner, R; Konstantinidis, N; Sutton, M

    2009-01-01

    The existing ATLAS Level-1 trigger system is seriously challenged at the SLHC's higher luminosity. A hardware tracking trigger might be needed, but requires a detailed understanding of the detector. Simulation of high pile-up events, with various data-reduction techniques applied will be described. Two scenarios are envisaged: (a) regional readout - calorimeter and muon triggers are used to identify portions of the tracker; and (b) track-stub finding using special trigger layers. A proposed hardware system, including data reduction on the front-end ASICs, readout within a super-module and integrating regional triggering into all levels of the readout system, will be discussed.

  12. Using a neural network approach for muon reconstruction and triggering

    CERN Document Server

    Etzion, E; Abramowicz, H; Benhammou, Ya; Horn, D; Levinson, L; Livneh, R

    2004-01-01

    The extremely high rate of events that will be produced in the future Large Hadron Collider requires the triggering mechanism to take precise decisions in a few nano-seconds. We present a study which used an artificial neural network triggering algorithm and compared it to the performance of a dedicated electronic muon triggering system. Relatively simple architecture was used to solve a complicated inverse problem. A comparison with a realistic example of the ATLAS first level trigger simulation was in favour of the neural network. A similar architecture trained after the simulation of the electronics first trigger stage showed a further background rejection.

  13. The ATLAS b-jet Trigger

    CERN Document Server

    Ferreira de Lima, D E; The ATLAS collaboration

    2011-01-01

    The ATLAS detector, at the LHC, has a three-level trigger, which selects events relevant for the physics goals of the experiment. The identification of jets arising from bottom quark production is important in many analyses. The b-tagging at the ATLAS Trigger relies on the fragmentation of the b quark, which generates a B hadron, that retains most of the parent quark’s momentum (∼ 70%). Furthermore, the high b quark mass results in decay products with high momenta with respect to the jet axis. The lifetime tagger relies on the the relatively long lifetime of the B hadrons (∼ 1.6 ps in their rest frame), which allows them to have a long decay length. Due to the large mass of the B hadron, the tracks reconstructed from this decay often have large impact parameters, compared to prompt jets. The algorithms exploit this by identifying tracks from the B hadron decay which are displaced from the primary interaction vertex and thus, indicate that a long-lived particle was present. The latest performance results...

  14. Soudan 2 data acquisition and trigger electronics

    International Nuclear Information System (INIS)

    Dawson, J.; Haberichter, W.; Laird, R.

    1985-01-01

    The 1.1 kton Soudan 2 calorimetric drift-chamber detector is read out by 16K anode wires and 32K cathode strips. Preamps from each wire or strip are bussed together in groups of 8 to reduce the number of ADC channels. The resulting 6144 channels of ionization signal are flash-digitized every 200 ns and stored in RAM. The raw data hit patterns are continually compared with programmable trigger multiplicity and adjacency conditions. The data acquisition process is managed in a system of 24 parallel crates each containing an Intel 80C86 microprocessor, which supervises a pipe-lined data compactor, and allows transfer of the compacted data via CAMAC to the host computer. The 80C86's also manage the local trigger conditions and can perform some parallel processing of the data. Due to the scale of the system and multiplicity of identical channels, semi-custom gate array chips are used for much of the logic, utilizing 2.5 micron CMOS technology

  15. Test of special resolution and trigger efficiency

    CERN Document Server

    Benhammou, Y

    2015-01-01

    The forthcoming luminosity upgrade of LHC to super-LHC (sLHC) will increase the expected background rate in the forward region of the ATLAS Muon Spectrometer by approximately the factor of five. Some of the present Muon Spectrometer components will fail to cope with these high rates and will have to be replaced. The results of a test of a device consisting of Thin Gap Chambers (TGC) and a fast small-diameter Muon Drift Tube Chamber (sMDT) using the 180 GeV/c muons at the SPS-H8 muon beam at CERN are presented. The goal of the test was to study the combined TGC-sMDT system as tracking and triggering device in the ATLAS muon spectrometer after high-luminosity upgrades of the LHC. The analysis of the recorded data shows a very good correlation between the TGC and sMDT track position and inclination. This technology offers the combination of trigger and tracking and has good angular and spatial resolutions. The angular resolution is 0.4 mrad for each system individually. For the spatial resolution, the width of t...

  16. Stress triggering and the Canterbury earthquake sequence

    Science.gov (United States)

    Steacy, Sandy; Jiménez, Abigail; Holden, Caroline

    2014-01-01

    The Canterbury earthquake sequence, which includes the devastating Christchurch event of 2011 February, has to date led to losses of around 40 billion NZ dollars. The location and severity of the earthquakes was a surprise to most inhabitants as the seismic hazard model was dominated by an expected Mw > 8 earthquake on the Alpine fault and an Mw 7.5 earthquake on the Porters Pass fault, 150 and 80 km to the west of Christchurch. The sequence to date has included an Mw = 7.1 earthquake and 3 Mw ≥ 5.9 events which migrated from west to east. Here we investigate whether the later events are consistent with stress triggering and whether a simple stress map produced shortly after the first earthquake would have accurately indicated the regions where the subsequent activity occurred. We find that 100 per cent of M > 5.5 earthquakes occurred in positive stress areas computed using a slip model for the first event that was available within 10 d of its occurrence. We further find that the stress changes at the starting points of major slip patches of post-Darfield main events are consistent with triggering although this is not always true at the hypocentral locations. Our results suggest that Coulomb stress changes contributed to the evolution of the Canterbury sequence and we note additional areas of increased stress in the Christchurch region and on the Porters Pass fault.

  17. The ATLAS Level-1 Calorimeter Trigger Architecture

    CERN Document Server

    Garvey, J; Mahout, G; Moye, T H; Staley, R J; Watkins, P M; Watson, A T; Achenbach, R; Hanke, P; Kluge, E E; Meier, K; Meshkov, P; Nix, O; Penno, K; Schmitt, K; Ay, Cc; Bauss, B; Dahlhoff, A; Jakobs, K; Mahboubi, K; Schäfer, U; Trefzger, T M; Eisenhandler, E F; Landon, M; Moyse, E; Thomas, J; Apostoglou, P; Barnett, B M; Brawn, I P; Davis, A O; Edwards, J; Gee, C N P; Gillman, A R; Perera, V J O; Qian, W; Bohm, C; Hellman, S; Hidvégi, A; Silverstein, S; RT 2003 13th IEEE-NPSS Real Time Conference

    2004-01-01

    The architecture of the ATLAS Level-1 Calorimeter Trigger system (L1Calo) is presented. Common approaches have been adopted for data distribution, result merging, readout, and slow control across the three different subsystems. A significant amount of common hardware is utilized, yielding substantial savings in cost, spares, and development effort. A custom, high-density backplane has been developed with data paths suitable for both the em/tt cluster processor (CP) and jet/energy-summation processor (JEP) subsystems. Common modules also provide interfaces to VME, CANbus and the LHC Timing, Trigger and Control system (TTC). A common data merger module (CMM) uses FPGAs with multiple configurations for summing electron/photon and tau/hadron cluster multiplicities, jet multiplicities, or total and missing transverse energy. The CMM performs both crate- and system-level merging. A common, FPGA-based readout driver (ROD) is used by all of the subsystems to send input, intermediate and output data to the data acquis...

  18. Progress in the High Level Trigger Integration

    CERN Multimedia

    Cristobal Padilla

    2007-01-01

    During the week from March 19th to March 23rd, the DAQ/HLT group performed another of its technical runs. On this occasion the focus was on integrating the Level 2 and Event Filter triggers, with a much fuller integration of HLT components than had been done previously. For the first time this included complete trigger slices, with a menu to run the selection algorithms for muons, electrons, jets and taus at the Level-2 and Event Filter levels. This Technical run again used the "Pre-Series" system (a vertical slice prototype of the DAQ/HLT system, see the ATLAS e-news January issue for details). Simulated events, provided by our colleagues working in the streaming tests, were pre-loaded into the ROS (Read Out System) nodes. These are the PC's where the data from the detector is stored after coming out of the front-end electronics, the "first part of the TDAQ system" and the interface to the detectors. These events used a realistic beam interaction mixture and had been subjected to a Level-1 selection. The...

  19. Soudan 2 data acquisition and trigger electronics

    International Nuclear Information System (INIS)

    Dawson, J.; Laird, R.; May, E.; Mondal, N.; Schlereth, J.; Solomey, N.; Thron, J.; Heppelmann, S.

    1985-01-01

    The 1.1 kton Soudan 2 detector is read out by 16K anode wires and 3 2K cathode strips. Preamps from each wire or strip are bussed together in groups of 8 to reduce the number of ADC channels. The resulting 6144 channels of ionization signal are flash-digitized every 150 ns and stored in RAM. The raw data hit patterns are continually compared with programmable trigger multiplicity and adjacency conditions. The data acquisition process is managed in a system of 24 parallel crates each containing an Intel 8086 microprocessors, which supervises a pipe-lined data compactors, and allows transfer of the compacted data via CAMAC to the host computer. The 8086's also manage the local trigger conditions and can perform some parallel processing of the data. Due to the scale of the system and multiplicity of identical channels, semi-custom gate array chips are used for much of the logic, utilizing 2.5 micron CMOS technology

  20. ATLAS calorimetry: Trigger, simulation and jet calibration

    CERN Document Server

    Weber, Pavel

    2008-01-01

    The Pre-Processor system of the ATLAS Level-1 Calorimeter Trigger performs complex processing of analog trigger tower signals from electromagnetic and hadronic calorimeters. The main processing block of the Pre-Processor System is the Multi-Chip Module (MCM). The first part of this thesis describes MCM quality assurance tests that have been developed, their use in the MCM large scale production and the results that have been obtained. In the second part of the thesis a validation of a shower parametrisation model for the ATLAS fast simulation package ATLFAST based on QCD dijet events is performed. A detailed comparison of jet response and jet energy resolution between the fast and the full simulation is presented. The uniformity of the calorimeter response has a significant impact on the accuracy of the jet energy measurement. A study of the calorimeter intercalibration using QCD dijet events is presented in the last part of the thesis. The intercalibration study is performed in azimuth angle phi and in pseud...

  1. Triggering of internal transport barrier in JET

    Energy Technology Data Exchange (ETDEWEB)

    Joffrin, E. [Association Euratom-CEA pour la Fusion, CEA Cadarache, St. Paul lez Durance (France); Gorini, G. [Istituto di Fisica del Plasma, EURATOM-ENEA-CNR Association, Milan (Italy); Challis, C.D. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon (United Kingdom)] [and others

    2002-08-01

    Internal transport barriers (ITBs) can be produced in JET by the application of strong additional heating during the current rise phase of the plasma discharge. Using up to 3 MW of lower hybrid power to tailor the q-profile prior to the main heating phase, a large variety of q-profiles ranging from low positive to strong negative central shear have been obtained during the current rise (0.4 MA s{sup -1}). With negative central magnetic shear s=(r/q)(r/q), the analysis of ITB triggering reveals a correlation between the formation of the ITB and q{sub andmin;} reaching an integer value (q=2 or q=3). This observation is confirmed by the analysis of the Alfven cascades. The minimum power required to access regimes with ITBs is probably related to the transport and magnetohydrodynamic properties of integer magnetic surfaces. Laser ablation and shallow pellet injection have also been attempted in recent JET ITB triggering experiments. (author)

  2. Reducing Environmental Allergic Triggers: Policy Issues.

    Science.gov (United States)

    Abramson, Stuart L

    The implementation of policies to reduce environmental allergic triggers can be an important adjunct to optimal patient care for allergic rhinitis and allergic asthma. Policies at the local level in schools and other public as well as private buildings can make an impact on disease morbidity. Occupational exposures for allergens have not yet been met with the same rigorous policy standards applied for exposures to toxicants by Occupational Safety and Health Administration. Further benefit may be obtained through policies by local, county, state, and national governments, and possibly through international cooperative agreements. The reduction of allergenic exposures can and should be affected by policies with strong scientific, evidence-based derivation. However, a judicious application of the precautionary principle may be needed in circumstances where the health effect of inaction could lead to more serious threats to vulnerable populations with allergic disease. This commentary covers the scientific basis, current implementation, knowledge gaps, and pro/con views on policy issues in reducing environmental allergic triggers. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. Pulse generator circuit triggerable by nuclear radiation

    International Nuclear Information System (INIS)

    Fredrickson, P.B.

    1980-01-01

    A pulse generator circuit triggerable by a pulse of nuclear radiation is described. The pulse generator circuit includes a pair of transistors arranged, together with other electrical components, in the topology of a standard monostable multivibrator circuit. The circuit differs most significantly from a standard monostable multivibrator circuit in that the circuit is adapted to be triggered by a pulse of nuclear radiation rather than electrically and the transistors have substantially different sensitivities to radiation, due to different physical and electrical characteristics and parameters. One of the transistors is employed principally as a radiation detector and is in a normally non-conducting state and the other transistor is normally in a conducting state. When the circuit is exposed to a pulse of nuclear radiation, currents are induced in the collector-base junctions of both transistors but, due to the different radiation sensitivities of the transistors, the current induced in the collector-base junction of the radiation-detecting transistor is substantially greater than that induced in the collector-base junction of the other transistor. The pulse of radiation causes the radiation-detecting transistor to operate in its conducting state, causing the other transistor to operate in its non-conducting state. As the radiation-detecting transistor operates in its conducting state, an output signal is produced at an output terminal connected to the radiation-detecting transistor indicating the presence of a predetermined intensity of nuclear radiation

  4. Soudan 2 data acquisition and trigger electronics

    International Nuclear Information System (INIS)

    Dawson, J.; Heppelmann, S.; Laird, R.; May, E.; Mondal, N.; Schlereth, J.; Solomey, N.; Thron, J.

    1985-01-01

    The 1.1 kton Soudan 2 detector is read out by 16K anode wires and 32K cathode strips. Preamps from each wire or strip are bussed together in groups of 8 to reduce the number of ADC channels. The resulting 6144 channels of ionization signal are flash-digitized every 150 ns and stored in RAM. The raw data hit patterns are continually compared with programmable trigger multiplicity and adjacency conditions. The data acquisition process is managed in a system of 24 parallel crates each containing an Intel 8086 microprocessors, which supervises a pipe-lined data compactors, and allows transfer of the compacted data via CAMAC to the host computer. The 8086's also manage the local trigger conditions and can perform some parallel processing of the data. Due to the scale of the system and multiplicity of identical channels, semi-custom gate array chips are used for much of the logic, utilizing 2.5 micron CMOS technology

  5. Nanocomposite thin films for triggerable drug delivery.

    Science.gov (United States)

    Vannozzi, Lorenzo; Iacovacci, Veronica; Menciassi, Arianna; Ricotti, Leonardo

    2018-05-01

    Traditional drug release systems normally rely on a passive delivery of therapeutic compounds, which can be partially programmed, prior to injection or implantation, through variations in the material composition. With this strategy, the drug release kinetics cannot be remotely modified and thus adapted to changing therapeutic needs. To overcome this issue, drug delivery systems able to respond to external stimuli are highly desirable, as they allow a high level of temporal and spatial control over drug release kinetics, in an operator-dependent fashion. Areas covered: On-demand drug delivery systems actually represent a frontier in this field and are attracting an increasing interest at both research and industrial level. Stimuli-responsive thin films, enabled by nanofillers, hold a tremendous potential in the field of triggerable drug delivery systems. The inclusion of responsive elements in homogeneous or heterogeneous thin film-shaped polymeric matrices strengthens and/or adds intriguing properties to conventional (bare) materials in film shape. Expert opinion: This Expert Opinion review aims to discuss the approaches currently pursued to achieve an effective on-demand drug delivery, through nanocomposite thin films. Different triggering mechanisms allowing a fine control on drug delivery are described, together with current challenges and possible future applications in therapy and surgery.

  6. ATLAS calorimetry. Trigger, simulation and jet calibration

    Energy Technology Data Exchange (ETDEWEB)

    Weber, P

    2007-02-06

    The Pre-Processor system of the ATLAS Level-1 Calorimeter Trigger performs complex processing of analog trigger tower signals from electromagnetic and hadronic calorimeters. The main processing block of the Pre-Processor System is the Multi-Chip Module (MCM). The first part of this thesis describes MCM quality assurance tests that have been developed, their use in the MCM large scale production and the results that have been obtained. In the second part of the thesis a validation of a shower parametrisation model for the ATLAS fast simulation package ATLFAST based on QCD dijet events is performed. A detailed comparison of jet response and jet energy resolution between the fast and the full simulation is presented. The uniformity of the calorimeter response has a significant impact on the accuracy of the jet energy measurement. A study of the calorimeter intercalibration using QCD dijet events is presented in the last part of the thesis. The intercalibration study is performed in azimuth angle {phi} and in pseudorapidity {eta}. The performance of the calibration methods including possible systematic and statistical effects is described. (orig.)

  7. The design and performance of the ATLAS jet trigger

    International Nuclear Information System (INIS)

    Shimizu, Shima

    2014-01-01

    The ATLAS jet trigger is an important element of the event selection process, providing data samples for studies of Standard Model physics and searches for new physics at the LHC. The ATLAS jet trigger system has undergone substantial modifications over the past few years of LHC operations, as experience developed with triggering in a high luminosity and high event pileup environment. In particular, the region-of-interest based strategy has been replaced by a full scan of the calorimeter data at the third trigger level, and by a full scan of the level-1 trigger input at level-2 for some specific trigger chains. Hadronic calibration and cleaning techniques are applied in order to provide improved performance and increased stability in high luminosity data taking conditions. In this note we discuss the implementation and operational aspects of the ATLAS jet trigger during 2011 and 2012 data taking periods at the LHC.

  8. submitter Muon trigger efficiency of the ATLAS Detector at LHC

    CERN Document Server

    Gallus, Petr

    The diploma thesis is devoted to the study of the muon trigger efficiency performance in the ATLAS experiment at the LHC collider. It contains measurements of efficiency of muon triggers of Level 1 and Level 2. Level 1 (LVL1) trigger efficiency of L1 MU20 and L1 2MU20 triggers is measured using Monte-Carlo simulated events. For Level 2 the efficiency of MuFast trigger is analysed in relation to the LVL1 decision. In both examples it is shown that the trigger efficiency depends on the detector geometry and transversal momentum pT of muons. Key words: ATLAS, LHC, trigger

  9. Commissioning the ATLAS Level-1 Central Trigger System

    CERN Document Server

    Sherman, Daniel

    2010-01-01

    The ATLAS Level-1 central trigger is a critical part of ATLAS operation. It receives the 40 MHz bunch clock from the LHC and distributes it to all sub-detectors. It initiates their read-out by forming the Level-1 Accept decision, which is based on information from the calorimeter and muon trigger processors and a variety of additional trigger inputs from detectors in the forward region. It also provides trigger summary information to the data acquisition system and the Level-2 trigger system. In this paper, we present the completion of the installed central trigger system, its performance during cosmic-ray data taking and the experience gained with triggering on the first LHC beams.

  10. The ATLAS Trigger Algorithms for General Purpose Graphics Processor Units

    CERN Document Server

    Tavares Delgado, Ademar; The ATLAS collaboration

    2016-01-01

    The ATLAS Trigger Algorithms for General Purpose Graphics Processor Units Type: Talk Abstract: We present the ATLAS Trigger algorithms developed to exploit General­ Purpose Graphics Processor Units. ATLAS is a particle physics experiment located on the LHC collider at CERN. The ATLAS Trigger system has two levels, hardware-­based Level 1 and the High Level Trigger implemented in software running on a farm of commodity CPU. Performing the trigger event selection within the available farm resources presents a significant challenge that will increase future LHC upgrades. are being evaluated as a potential solution for trigger algorithms acceleration. Key factors determining the potential benefit of this new technology are the relative execution speedup, the number of GPUs required and the relative financial cost of the selected GPU. We have developed a trigger demonstrator which includes algorithms for reconstructing tracks in the Inner Detector and Muon Spectrometer and clusters of energy deposited in the Cal...

  11. The ATLAS Level-1 Central Trigger Processor (CTP)

    CERN Document Server

    Spiwoks, Ralf; Ellis, Nick; Farthouat, P; Gällnö, P; Haller, J; Krasznahorkay, A; Maeno, T; Pauly, T; Pessoa-Lima, H; Resurreccion-Arcas, I; Schuler, G; De Seixas, J M; Torga-Teixeira, R; Wengler, T

    2005-01-01

    The ATLAS Level-1 Central Trigger Processor (CTP) combines information from calorimeter and muon trigger processors and makes the final Level-1 Accept (L1A) decision on the basis of lists of selection criteria (trigger menus). In addition to the event-selection decision, the CTP also provides trigger summary information to the Level-2 trigger and the data acquisition system. It further provides accumulated and bunch-by-bunch scaler data for monitoring of the trigger, detector and beam conditions. The CTP is presented and results are shown from tests with the calorimeter adn muon trigger processors connected to detectors in a particle beam, as well as from stand-alone full-system tests in the laboratory which were used to validate the CTP.

  12. Treatment of congestion in upper respiratory diseases

    Directory of Open Access Journals (Sweden)

    Eli O Meltzer

    2010-02-01

    Full Text Available Eli O Meltzer1, Fernan Caballero2, Leonard M Fromer3, John H Krouse4, Glenis Scadding51Allergy and Asthma Medical Group and Research Center, San Diego, CA and Department of Pediatrics, University of California, San Diego, USA; 2Allergy and Clinical Immunology Service, Centro Medico-Docente La Trinidad, Caracas, Venezuela; 3David Geffen School of Medicine, University of California, Los Angeles, USA; 4Wayne State University School of Medicine, Detroit, Michigan, USA; 5Department of Allergy and Rhinology, Royal National TNE Hospital, London, UKAbstract: Congestion, as a symptom of upper respiratory tract diseases including seasonal and perennial allergic rhinitis, acute and chronic rhinosinusitis, and nasal polyposis, is principally caused by mucosal inflammation. Though effective pharmacotherapy options exist, no agent is universally efficacious; therapeutic decisions must account for individual patient preferences. Oral H1-antihistamines, though effective for the common symptoms of allergic rhinitis, have modest decongestant action, as do leukotriene receptor antagonists. Intranasal antihistamines appear to improve congestion better than oral forms. Topical decongestants reduce congestion associated with allergic rhinitis, but local adverse effects make them unsuitable for long-term use. Oral decongestants show some efficacy against congestion in allergic rhinitis and the common cold, and can be combined with oral antihistamines. Intranasal corticosteroids have broad anti-inflammatory activities, are the most potent long-term pharmacologic treatment of congestion associated with allergic rhinitis, and show some congestion relief in rhinosinusitis and nasal polyposis. Immunotherapy and surgery may be used in some cases refractory to pharmacotherapy. Steps in congestion management include (1 diagnosis of the cause(s, (2 patient education and monitoring, (3 avoidance of environmental triggers where possible, (4 pharmacotherapy, and (5 immunotherapy

  13. Robot-Aided Upper-Limb Rehabilitation Based on Motor Imagery EEG

    Directory of Open Access Journals (Sweden)

    Baoguo Xu

    2011-09-01

    Full Text Available Stroke is a leading cause of disability worldwide. In this paper, a novel robot‐assisted rehabilitation system based on motor imagery electroencephalography (EEG is developed for regular training of neurological rehabilitation for upper limb stroke patients. Firstly, three‐dimensional animation was used to guide the patient image the upper limb movement and EEG signals were acquired by EEG amplifier. Secondly, eigenvectors were extracted by harmonic wavelet transform (HWT and linear discriminant analysis (LDA classifier was utilized to classify the pattern of the left and right upper limb motor imagery EEG signals. Finally, PC triggered the upper limb rehabilitation robot to perform motor therapy and gave the virtual feedback. Using this robot‐assisted upper limb rehabilitation system, the patientʹs EEG of upper limb movement imagination is translated to control rehabilitation robot directly. Consequently, the proposed rehabilitation system can fully explore the patientʹs motivation and attention and directly facilitate upper limb post‐stroke rehabilitation therapy. Experimental results on unimpaired participants were presented to demonstrate the feasibility of the rehabilitation system. Combining robot‐assisted training with motor imagery‐ based BCI will make future rehabilitation therapy more effective. Clinical testing is still required for further proving this assumption.

  14. Robot-Aided Upper-Limb Rehabilitation Based on Motor Imagery EEG

    Directory of Open Access Journals (Sweden)

    Baoguo Xu

    2011-09-01

    Full Text Available Stroke is a leading cause of disability worldwide. In this paper, a novel robot-assisted rehabilitation system based on motor imagery electroencephalography (EEG is developed for regular training of neurological rehabilitation for upper limb stroke patients. Firstly, three-dimensional animation was used to guide the patient image the upper limb movement and EEG signals were acquired by EEG amplifier. Secondly, eigenvectors were extracted by harmonic wavelet transform (HWT and linear discriminant analysis (LDA classifier was utilized to classify the pattern of the left and right upper limb motor imagery EEG signals. Finally, PC triggered the upper limb rehabilitation robot to perform motor therapy and gave the virtual feedback. Using this robot-assisted upper limb rehabilitation system, the patient's EEG of upper limb movement imagination is translated to control rehabilitation robot directly. Consequently, the proposed rehabilitation system can fully explore the patient's motivation and attention and directly facilitate upper limb post-stroke rehabilitation therapy. Experimental results on unimpaired participants were presented to demonstrate the feasibility of the rehabilitation system. Combining robot-assisted training with motor imagery-based BCI will make future rehabilitation therapy more effective. Clinical testing is still required for further proving this assumption.

  15. Empty follicle syndrome after GnRHa triggering versus hCG triggering in COS

    DEFF Research Database (Denmark)

    Castillo, Juan C; Garcia-Velasco, Juan; Humaidan, Peter

    2012-01-01

    This study aimed to explore the incidence of empty follicle syndrome (EFS) in oocyte donors who had final oocyte maturation triggered with GnRHa and to compare the incidence of EFS in this group of patients with IVF patients who had final oocyte maturation with hCG....

  16. The ATLAS trigger high-level trigger commissioning and operation during early data taking

    CERN Document Server

    Goncalo, R

    2008-01-01

    The ATLAS experiment is one of the two general-purpose experiments due to start operation soon at the Large Hadron Collider (LHC). The LHC will collide protons at a centre of mass energy of 14~TeV, with a bunch-crossing rate of 40~MHz. The ATLAS three-level trigger will reduce this input rate to match the foreseen offline storage capability of 100-200~Hz. After the Level 1 trigger, which is implemented in custom hardware, the High-Level Trigger (HLT) further reduces the rate from up to 100~kHz to the offline storage rate while retaining the most interesting physics. The HLT is implemented in software running in commercially available computer farms and consists of Level 2 and Event Filter. To reduce the network data traffic and the processing time to manageable levels, the HLT uses seeded, step-wise reconstruction, aiming at the earliest possible rejection. Data produced during LHC commissioning will be vital for calibrating and aligning sub-detectors, as well as for testing the ATLAS trigger and setting up t...

  17. The ATLAS High Level Trigger Steering Framework and the Trigger Configuration System.

    CERN Document Server

    Perez Cavalcanti, Tiago; The ATLAS collaboration

    2011-01-01

    The ATLAS detector system installed in the Large Hadron Collider (LHC) at CERN is designed to study proton-proton and nucleus-nucleus collisions with a maximum centre of mass energy of 14 TeV at a bunch collision rate of 40MHz. In March 2010 the four LHC experiments saw the first proton-proton collisions at 7 TeV. Still within the year a collision rate of nearly 10 MHz is expected. At ATLAS, events of potential interest for ATLAS physics are selected by a three-level trigger system, with a final recording rate of about 200 Hz. The first level (L1) is implemented in custom hardware; the two levels of the high level trigger (HLT) are software triggers, running on large farms of standard computers and network devices. Within the ATLAS physics program more than 500 trigger signatures are defined. The HLT tests each signature on each L1-accepted event; the test outcome is recorded for later analysis. The HLT-Steering is responsible for this. It foremost ensures the independent test of each signature, guarantying u...

  18. Response of upper ocean cooling off northeastern Taiwan to typhoon passages

    Science.gov (United States)

    Zheng, Zhe-Wen; Zheng, Quanan; Gopalakrishnan, Ganesh; Kuo, Yi-Chun; Yeh, Ting-Kuang

    2017-07-01

    A comprehensive investigation of the typhoon induced upper ocean processes and responses off northeastern Taiwan was conducted. Using the Regional Ocean Modeling System, the upper ocean responses of all typhoons striking Taiwan between 2005 and 2013 were simulated. In addition to Kuroshio intrusion, the present study demonstrates another important mechanism of typhoon induced near-inertial currents over the continental shelf of East China Sea, which can also trigger a distinct cooling (through entrainment mixing) within this region. Results indicate that the processes of typhoon inducing distinct cooling off northeastern Taiwan are conditional phenomena (only ∼12% of typhoons passing Taiwan triggered extreme cooling there). Subsequently, by executing a series of sensitivity experiments and systematic analyses on the behaviors and background conditions of all those typhoon cases, key criteria determining the occurrences of cooling through both mechanisms were elucidated. Occurrences of cooling through the Kuroshio intrusion mechanism are determined mainly by the strength of the local wind over northeastern Taiwan. A distinct cooling triggered by enhanced near-inertial currents is shown to be associated with the process of wind-current resonance. Both processes of Kuroshio intrusion and enhanced near-inertial currents are dominated by wind forcing rather than upper oceanic conditions. Based on the recent findings on the possible dynamic linkage between sea surface temperature near northeast Taiwan and local weather systems, the results elucidated in this study lay the foundation for further improvement in the regional weather prediction surrounding northeast Taiwan.

  19. Simultaneous Event-Triggered Fault Detection and Estimation for Stochastic Systems Subject to Deception Attacks.

    Science.gov (United States)

    Li, Yunji; Wu, QingE; Peng, Li

    2018-01-23

    In this paper, a synthesized design of fault-detection filter and fault estimator is considered for a class of discrete-time stochastic systems in the framework of event-triggered transmission scheme subject to unknown disturbances and deception attacks. A random variable obeying the Bernoulli distribution is employed to characterize the phenomena of the randomly occurring deception attacks. To achieve a fault-detection residual is only sensitive to faults while robust to disturbances, a coordinate transformation approach is exploited. This approach can transform the considered system into two subsystems and the unknown disturbances are removed from one of the subsystems. The gain of fault-detection filter is derived by minimizing an upper bound of filter error covariance. Meanwhile, system faults can be reconstructed by the remote fault estimator. An recursive approach is developed to obtain fault estimator gains as well as guarantee the fault estimator performance. Furthermore, the corresponding event-triggered sensor data transmission scheme is also presented for improving working-life of the wireless sensor node when measurement information are aperiodically transmitted. Finally, a scaled version of an industrial system consisting of local PC, remote estimator and wireless sensor node is used to experimentally evaluate the proposed theoretical results. In particular, a novel fault-alarming strategy is proposed so that the real-time capacity of fault-detection is guaranteed when the event condition is triggered.

  20. Triggering of acute myocardial infarction by respiratory infection.

    Science.gov (United States)

    Ruane, Lorcan; Buckley, Thomas; Hoo, Soon Y S; Hansen, Peter S; McCormack, Catherine; Shaw, Elizabeth; Fethney, Judith; Tofler, Geoffrey H

    2017-05-01

    Respiratory infection has been associated with an increased short-term risk of myocardial infarction (MI). However, previous studies have predominantly been conducted without angiographic confirmation of MI. The possibility can therefore not be excluded that raised troponin levels or electrocardiogram abnormalities that may be seen with respiratory infections are due to non-ischaemic causes. To investigate the association between respiratory infection and angiographically confirmed MI. Interviews were conducted within 4 days of hospitalisation in 578 patients with angiographically confirmed MI, to assess for recent exposure to respiratory infection symptoms and the usual annual frequency of these symptoms. Using case-crossover methodology, exposure to respiratory infection prior to the onset of MI was compared against the usual frequency of exposure in the past year. Symptoms of respiratory infection were reported by 100 (17%) and 123 (21%) within 7 and 35 days, respectively, prior to MI. The relative risk (RR) for MI occurring within 1-7 days after respiratory infection symptoms was 17.0 (95% confidence interval (CI) 13.2-21.8), and declined with subsequent time periods. In a subgroup analysis, the RR tended to be lower in groups taking regular cardiac medications. For those who reported milder, upper respiratory tract infection symptoms, the RR for the 1-7-day time period was 13.5 (95% CI 10.2-17.7). These findings confirm that respiratory infection can trigger MI. Further study is indicated to identify treatment strategies to decrease this risk, particularly in individuals who may have increased susceptibility. © 2017 Royal Australasian College of Physicians.

  1. Nonlinear Viscoelastic Mechanism for Aftershock Triggering and Decay

    Science.gov (United States)

    Shcherbakov, R.; Zhang, X.

    2016-12-01

    Aftershocks are ubiquitous in nature. They are the manifestation of relaxation phenomena observed in various physical systems. In one prominent example, they typically occur after large earthquakes. They also occur in other natural or experimental systems, for example, in solar flares, in fracture experiments on porous materials and acoustic emissions, after stock market crashes, in the volatility of stock prices returns, in internet traffic variability and e-mail spamming, to mention a few. The observed aftershock sequences usually obey several well defined non-trivial empirical laws in magnitude, temporal, and spatial domains. In many cases their characteristics follow scale-invariant distributions. The occurrence of aftershocks displays a prominent temporal behavior due to time-dependent mechanisms of stress and/or energy transfer. In this work, we consider a slider-block model to mimic the behavior of a seismogenic fault. In the model, we introduce a nonlinear viscoelastic coupling mechanism to capture the essential characteristics of crustal rheology and stress interaction between the blocks and the medium. For this purpose we employ nonlinear Kelvin-Voigt elements consisting of an elastic spring and a dashpot assembled in parallel to introduce viscoelastic coupling between the blocks and the driving plate. By mapping the model into a cellular automaton we derive the functional form of the stress transfer mechanism in the model. We show that the nonlinear viscoelasticity plays a critical role in triggering of aftershocks. It explains the functional form of the Omori-Utsu law and gives physical interpretation of its parameters. The proposed model also suggests that the power-law rheology of the fault gauge and underlying lower crust and upper mantle control the decay rate of aftershocks. To verify this, we analyze several prominent aftershock sequences to estimate their decay rates and correlate with the rheological properties of the underlying lower crust and

  2. The Upper Danube Nature Park

    International Nuclear Information System (INIS)

    Dosedla, H.C.

    1997-01-01

    When in 1980 the Upper Danube Nature Park was founded as one of 65 nature sanctuaries in Germany there was great diversity of opinions concerning its intended character. The protected region consisting of a geologically outstanding landscape within central Europe is covering the first 80 km the upper Danube where the young river shortly after it's source in the Black Forest is breaking through the narrow canyons of the Jurassic rock plateau of the so-called Suebian Alps and also locates the subterranean passage where the stream is submerging from the surface for nearly ten miles. Since the purpose of nature preservation according to German las is closely combined with the rather contradicting aim of offering an attractive recreation area thus facing the immense impacts of modern mass tourism there are numerous problems which in the course of years have resulted in an intricate patterns of subtle management methods coping with the growing awareness of the ecological balance. (author)

  3. Accounting for the social triggers of sexual compulsivity.

    Science.gov (United States)

    Parsons, Jeffrey T; Kelly, Brian C; Bimbi, David S; Muench, Frederick; Morgenstern, Jon

    2007-01-01

    To examine the social triggers of sexual compulsivity amongst a diverse sample of gay and bisexual men. Qualitative interviews were conducted with 180 gay and bisexual men in the United States who self-identified that their sex lives were spinning out of control. The data were analyzed using a grounded theory approach to explore the range of social triggers that were driving sexual compulsions. An open-ended interview and a structured clinical interview were conducted with each participant. The interviews examined their experiences with sexual compulsivity over time and the impact of their problematic sexual behaviors on their lives. Two types of social triggers emerged from the data: event-centered triggers and contextual triggers. Event-centered triggers arise from sudden, unforeseen events. Two major event-centered triggers were identified: relationship turmoil and catastrophes. Contextual triggers, on the other hand, have a certain element of predictability, and included such things as location, people, the use of drugs, and pornography. This framework of triggers has clinical implications for the prevention and treatment of sexual compulsivity. Clinicians can utilize the framework of social triggers in the therapeutic process to provide insight into ways to effectively work through symptoms of sexual compulsivity. Awareness of the contextual aspects of sexual compulsivity may be critical to understanding the behaviors of sexually compulsive clients. Thus, therapeutic assessments should focus upon the social context in addition to the psychological components of the disorder.

  4. Upper limit of peak area

    International Nuclear Information System (INIS)

    Helene, O.A.M.

    1982-08-01

    The determination of the upper limit of peak area in a multi-channel spectra, with a known significance level is discussed. This problem is specially important when the peak area is masked by the background statistical fluctuations. The problem is exactly solved and, thus, the results are valid in experiments with small number of events. The results are submitted to a Monte Carlo test and applied to the 92 Nb beta decay. (Author) [pt

  5. A multiplicity trigger for a Cherenkov detector

    International Nuclear Information System (INIS)

    Jonsson, P.

    1984-05-01

    The Multiplicity Trigger (MT) is a device for deciding if, in a given time window, the number of wires that are hit in a multi wire proportional chamber (MWPC) is within given limits. The MT is designed for a Cherenkov detector, using a MWPC with 155 sense wires. It has ten inputs with sixteen channels on each, for 160 ECL input signals from the MWPC. With the MT, it is possible to decide if the number of hits is greater than n out of 160, where n is called the multiplicity. Here, 2 < n < 30, with an accuracy of +- 1. The time window can be adjusted from 0.7 to 4 μs. The MT has four separate NIM outputs, to make it possible to have four different values of n at the same time. The propagation delay from input to output is at the most 100 ns. (author)

  6. Self-triggering detectors for recoil nuclei

    International Nuclear Information System (INIS)

    Aleksanyan, A.S.; Asatiani, T.I.; Gasparyan, A.O.

    1975-01-01

    Hybrid α-detectors consisting of wide gap spark chambers and signal α detectors are described. The investigations have been carried out with γ-beams of Yerevan Electron Synchrotron. The possibility of using such detectors in the experiments on particle photoproduction on gas helium with the determination of the interaction point, emission angle of the recoil nucleus and its energy by means of range measurement has been shown. It has been shown that self - triggering wide gap spark chamber allows to detect and measure the range of the recoil nuclei α-particles with energies Esub(α) > or approximately (1 - 2) Mev which correspond to momentum transfers apprxomation (10 -2 - 10 -3 ) (GeV/c) 2

  7. The ATLAS Trigger Simulation with Legacy Software

    CERN Document Server

    Bernius, Catrin; The ATLAS collaboration

    2017-01-01

    Physics analyses at the LHC require accurate simulations of the detector response and the event selection processes, generally done with the most recent software releases. The trigger response simulation is crucial for determination of overall selection efficiencies and signal sensitivities and should be done with the same software release with which data were recorded. This requires potentially running with software dating many years back, the so-called legacy software. Therefore having a strategy for running legacy software in a modern environment becomes essential when data simulated for past years start to present a sizeable fraction of the total. The requirements and possibilities for such a simulation scheme within the ATLAS software framework were examined and a proof-of-concept simulation chain has been successfully implemented. One of the greatest challenges was the choice of a data format which promises long term compatibility with old and new software releases. Over the time periods envisaged, data...

  8. The CMS High Level Trigger System

    CERN Document Server

    Afaq, A; Bauer, G; Biery, K; Boyer, V; Branson, J; Brett, A; Cano, E; Carboni, A; Cheung, H; Ciganek, M; Cittolin, S; Dagenhart, W; Erhan, S; Gigi, D; Glege, F; Gómez-Reino, Robert; Gulmini, M; Gutiérrez-Mlot, E; Gutleber, J; Jacobs, C; Kim, J C; Klute, M; Kowalkowski, J; Lipeles, E; Lopez-Perez, Juan Antonio; Maron, G; Meijers, F; Meschi, E; Moser, R; Murray, S; Oh, A; Orsini, L; Paus, C; Petrucci, A; Pieri, M; Pollet, L; Rácz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Sexton-Kennedy, E; Sumorok, K; Suzuki, I; Tsirigkas, D; Varela, J

    2007-01-01

    The CMS Data Acquisition (DAQ) System relies on a purely software driven High Level Trigger (HLT) to reduce the full Level-1 accept rate of 100 kHz to approximately 100 Hz for archiving and later offline analysis. The HLT operates on the full information of events assembled by an event builder collecting detector data from the CMS front-end systems. The HLT software consists of a sequence of reconstruction and filtering modules executed on a farm of O(1000) CPUs built from commodity hardware. This paper presents the architecture of the CMS HLT, which integrates the CMS reconstruction framework in the online environment. The mechanisms to configure, control, and monitor the Filter Farm and the procedures to validate the filtering code within the DAQ environment are described.

  9. Trigger delay compensation of beam synchronous sampling

    International Nuclear Information System (INIS)

    Steimel, J.

    1996-05-01

    One of the problems of providing beam feedback in a large accelerator is the lack of beam synchronous trigger signals far from the RF signal source. IF single bucket resolutions are required, a cable extending from the RF source to the other side of the accelerator will not provide a synchronous signal if the RF frequency changes significantly with respect to the cable delay. This paper offers a solution to this problem by locking to the RF, at the remote location, using a digital phase locked loop. Then, the digitized frequency value is used to calculate the phase shift required to remain synchronized to the beam. Results are shown for phase lock to the Fermilab Main Ring RF. 1 ref., 4 figs

  10. Technology improves upper extremity rehabilitation.

    Science.gov (United States)

    Kowalczewski, Jan; Prochazka, Arthur

    2011-01-01

    Stroke survivors with hemiparesis and spinal cord injury (SCI) survivors with tetraplegia find it difficult or impossible to perform many activities of daily life. There is growing evidence that intensive exercise therapy, especially when supplemented with functional electrical stimulation (FES), can improve upper extremity function, but delivering the treatment can be costly, particularly after recipients leave rehabilitation facilities. Recently, there has been a growing level of interest among researchers and healthcare policymakers to deliver upper extremity treatments to people in their homes using in-home teletherapy (IHT). The few studies that have been carried out so far have encountered a variety of logistical and technical problems, not least the difficulty of conducting properly controlled and blinded protocols that satisfy the requirements of high-level evidence-based research. In most cases, the equipment and communications technology were not designed for individuals with upper extremity disability. It is clear that exercise therapy combined with interventions such as FES, supervised over the Internet, will soon be adopted worldwide in one form or another. Therefore it is timely that researchers, clinicians, and healthcare planners interested in assessing IHT be aware of the pros and cons of the new technology and the factors involved in designing appropriate studies of it. It is crucial to understand the technical barriers, the role of telesupervisors, the motor improvements that participants can reasonably expect and the process of optimizing IHT-exercise therapy protocols to maximize the benefits of the emerging technology. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Study of Tectonic Tremor in Depth: Triggering Stress Observation and Model of the Triggering Mechanism

    Science.gov (United States)

    Wang, Tien-Huei

    Non-volcanic tremor (NVT) has been discovered in recent years due to advances in seismic instruments and increased density of seismic networks. The NVT is a special kind of seismic signal indicative of the physical conditions and the failure mechanism on the source on the fault where NVT occurs. The detection methods used and the sensitivity of them relies on the density, distance and instrumentation of the station network available. How accurately the tremor is identified in different regions varies greatly among different studies. Therefore, there has not been study that rigorously documents tectonic tremors in different regions under limited methods and data. Meanwhile, many incidences of NVTs are observed during or after small but significant strain change induced by teleseismic, regional or local earthquake. The understanding of the triggering mechanisms critical for tremor remains unclear. In addition, characteristics of the triggering of NVT in different regions are rarely compared because of the short time frame after the discovery of the triggered NVTs. We first explore tectonic tremor based on observations to learn about its triggering, frequency of occurrence, location and spectral characteristics. Then, we numerically model the triggering of instability on the estimated tremor-source, under assumptions fine-tuned according to previous studies (Thomas et al., 2009; Miyazawa et al., 2005; Hill, 2008; Ito, 2009; Rubinstein et al., 2007; Peng and Chao, 2008). The onset of the slip reveals that how and when the external loading triggers tremor. It also holds the information to the background stress conditions under which tremor source starts with. We observe and detect tremor in two regions: Anza and Cholame, along San Jacinto Fault (SJF) and San Andreas Fault (SAF) respectively. These two sections of the faults, relative to general fault zone on which general earthquakes occur, are considered transition zones where slip of slow rates occurs. Slip events

  12. Improved Mars Upper Atmosphere Climatology

    Science.gov (United States)

    Bougher, S. W.

    2004-01-01

    The detailed characterization of the Mars upper atmosphere is important for future Mars aerobraking activities. Solar cycle, seasonal, and dust trends (climate) as well as planetary wave activity (weather) are crucial to quantify in order to improve our ability to reasonably depict the state of the Mars upper atmosphere over time. To date, our best information is found in the Mars Global Surveyor (MGS) Accelerometer (ACC) database collected during Phase 1 (Ls = 184 - 300; F10.7 = 70 - 90) and Phase 2 (Ls = 30 - 90; F10.7 = 90 - 150) of aerobraking. This database (100 - 170 km) consists of thermospheric densities, temperatures, and scale heights, providing our best constraints for exercising the coupled Mars General Circulation Model (MGCM) and the Mars Thermospheric General Circulation Model (MTGCM). The Planetary Data System (PDS) contains level 0 and 2 MGS Accelerometer data, corresponding to atmospheric densities along the orbit track. Level 3 products (densities, temperatures, and scale heights at constant altitudes) are also available in the PDS. These datasets provide the primary model constraints for the new MGCM-MTGCM simulations summarized in this report. Our strategy for improving the characterization of the Mars upper atmospheres using these models has been three-fold : (a) to conduct data-model comparisons using the latest MGS data covering limited climatic and weather conditions at Mars, (b) to upgrade the 15-micron cooling and near-IR heating rates in the MGCM and MTGCM codes for ad- dressing climatic variations (solar cycle and seasonal) important in linking the lower and upper atmospheres (including migrating tides), and (c) to exercise the detailed coupled MGCM and MTGCM codes to capture and diagnose the planetary wave (migrating plus non-migrating tidal) features throughout the Mars year. Products from this new suite of MGCM-MTGCM coupled simulations are being used to improve our predictions of the structure of the Mars upper atmosphere for the

  13. GPUs for real-time processing in HEP trigger systems

    CERN Document Server

    Ammendola, R; Deri, L; Fiorini, M; Frezza, O; Lamanna, G; Lo Cicero, F; Lonardo, A; Messina, A; Sozzi, M; Pantaleo, F; Paolucci, Ps; Rossetti, D; Simula, F; Tosoratto, L; Vicini, P

    2014-01-01

    We describe a pilot project (GAP - GPU Application Project) for the use of GPUs (Graphics processing units) for online triggering applications in High Energy Physics experiments. Two major trends can be identied in the development of trigger and DAQ systems for particle physics experiments: the massive use of general-purpose commodity systems such as commercial multicore PC farms for data acquisition, and the reduction of trigger levels implemented in hardware, towards a fully software data selection system (\\trigger-less"). The innovative approach presented here aims at exploiting the parallel computing power of commercial GPUs to perform fast computations in software not only in high level trigger levels but also in early trigger stages. General-purpose computing on GPUs is emerging as a new paradigm in several elds of science, although so far applications have been tailored to the specic strengths of such devices as accelerators in oine computation. With the steady reduction of GPU latencies, and the incre...

  14. A Time-Multiplexed Track-Trigger architecture for CMS

    CERN Document Server

    Hall, Geoffrey; Pesaresi, Mark Franco; Rose, A

    2014-01-01

    The CMS Tracker under development for the High Luminosity LHC includes an outer tracker based on ``PT-modules'' which will provide track stubs based on coincident clusters in two closely spaced sensor layers, aiming to reject low transverse momentum track hits before data transmission to the Level-1 trigger. The tracker data will be used to reconstruct track segments in dedicated processors before onward transmission to other trigger processors which will combine tracker information with data originating from the calorimeter and muon detectors, to make the final L1 trigger decision. The architecture for processing the tracker data is still an open question. One attractive option is to explore a Time Multiplexed design similar to one which is currently being implemented in the CMS calorimeter trigger as part of the Phase I trigger upgrade. The Time Multiplexed Trigger concept is explained, the potential benefits of applying it for processing future tracker data are described and a possible design based on cur...

  15. Performance of the ATLAS Muon Trigger in Run 2

    CERN Document Server

    Morgenstern, Marcus; The ATLAS collaboration

    2018-01-01

    Events containing muons in the final state are an important signature for many analyses being carried out at the Large Hadron Collider (LHC), including both standard model measurements and searches for new physics. To be able to study such events, it is required to have an efficient and well-understood muon trigger. The ATLAS muon trigger consists of a hardware based system (Level 1), as well as a software based reconstruction (High Level Trigger). Due to high luminosity and pile up conditions in Run 2, several improvements have been implemented to keep the trigger rate low while still maintaining a high efficiency. Some examples of recent improvements include requiring coincidence hits between different layers of the muon spectrometer, improvements for handling overlapping muons, and optimised muon isolation. We will present an overview of how we trigger on muons, recent improvements, and the performance of the muon trigger in Run 2 data.

  16. Simulation of the ATLAS New Small Wheel trigger

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00399900; The ATLAS collaboration

    2018-01-01

    The instantaneous luminosity of the LHC will increase up to a factor of seven with respect to the original design value to explore physics at higher energy scale. The inner station of the ATLAS muon end-cap system (Small Wheel) will be replaced by the New Small Wheel (NSW) to benefit from the high luminosity. The NSW will provide precise track-segment information to the Level-1 trigger system in order to suppress the trigger rate from fake muon tracks. This article summarizes the NSW trigger decision system and track-segment finding algorithm implemented in the trigger processor, and discusses results of performance studies on the trigger system. The results demonstrate that the NSW trigger system is capable of working with good performance satisfying the requirements.

  17. Simulation and Validation of the ATLAS Level-1 Topological Trigger

    CERN Document Server

    Bakker, Pepijn Johannes; The ATLAS collaboration

    2017-01-01

    The ATLAS experiment has recently commissioned a new component of its first-level trigger: the L1 topological trigger. This system, using state-of-the-art FPGA processors, makes it possible to reject events by applying topological requirements, such as kinematic criteria involving clusters, jets, muons, and total transverse energy. The data recorded using the L1Topological trigger demonstrates that this innovative trigger strategy allows for an improved rejection rate without efficiency loss. This improvement has been shown for several relevant physics processes leading to low-$p_T$ leptons, including $H\\to{}\\tau{}\\tau{}$ and $J/\\Psi\\to{}\\mu{}\\mu{}$. In addition, an accurate simulation of the L1Topological trigger is used to validate and optimize the performance of this trigger. To reach such an accuracy, this simulation must take into account the fact that the firmware algorithms are executed on a FPGA architecture, while the simulation is executed on a floating point architecture.

  18. The ATLAS High-Level Calorimeter Trigger in Run-2

    CERN Document Server

    Wiglesworth, Craig; The ATLAS collaboration

    2018-01-01

    The ATLAS Experiment uses a two-level triggering system to identify and record collision events containing a wide variety of physics signatures. It reduces the event rate from the bunch-crossing rate of 40 MHz to an average recording rate of 1 kHz, whilst maintaining high efficiency for interesting collision events. It is composed of an initial hardware-based level-1 trigger followed by a software-based high-level trigger. A central component of the high-level trigger is the calorimeter trigger. This is responsible for processing data from the electromagnetic and hadronic calorimeters in order to identify electrons, photons, taus, jets and missing transverse energy. In this talk I will present the performance of the high-level calorimeter trigger in Run-2, noting the improvements that have been made in response to the challenges of operating at high luminosity.

  19. Performance of the ATLAS Trigger System in 2010

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdelalim, Ahmed Ali; Abdesselam, Abdelouahab; Abdinov, Ovsat; Abi, Babak; Abolins, Maris; Abramowicz, Halina; Abreu, Henso; Acerbi, Emilio; Acharya, Bobby Samir; Adams, David; Addy, Tetteh; Adelman, Jahred; Aderholz, Michael; Adomeit, Stefanie; Adragna, Paolo; Adye, Tim; Aefsky, Scott; Aguilar-Saavedra, Juan Antonio; Aharrouche, Mohamed; Ahlen, Steven; Ahles, Florian; Ahmad, Ashfaq; Ahsan, Mahsana; Aielli, Giulio; Akdogan, Taylan; Åkesson, Torsten Paul Ake; Akimoto, Ginga; Akimov, Andrei; Akiyama, Kunihiro; Alam, Mohammad; Alam, Muhammad Aftab; Albrand, Solveig; Aleksa, Martin; Aleksandrov, Igor; Alessandria, Franco; Alexa, Calin; Alexander, Gideon; Alexandre, Gauthier; Alexopoulos, Theodoros; Alhroob, Muhammad; Aliev, Malik; Alimonti, Gianluca; Alison, John; Aliyev, Magsud; Allport, Phillip; Allwood-Spiers, Sarah; Almond, John; Aloisio, Alberto; Alon, Raz; Alonso, Alejandro; Alviggi, Mariagrazia; Amako, Katsuya; Amaral, Pedro; Amelung, Christoph; Ammosov, Vladimir; Amorim, Antonio; Amorós, Gabriel; Amram, Nir; Anastopoulos, Christos; Andari, Nansi; Andeen, Timothy; Anders, Christoph Falk; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Andrieux, Marie-Laure; Anduaga, Xabier; Angerami, Aaron; Anghinolfi, Francis; Anjos, Nuno; Annovi, Alberto; Antonaki, Ariadni; Antonelli, Mario; Antonelli, Stefano; Antonov, Alexey; Antos, Jaroslav; Anulli, Fabio; Aoun, Sahar; Aperio Bella, Ludovica; Apolle, Rudi; Arabidze, Giorgi; Aracena, Ignacio; Arai, Yasuo; Arce, Ayana; Archambault, John-Paul; Arfaoui, Samir; Arguin, Jean-Francois; Arik, Engin; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnault, Christian; Artamonov, Andrei; Artoni, Giacomo; Arutinov, David; Asai, Shoji; Asfandiyarov, Ruslan; Ask, Stefan; Åsman, Barbro; Asquith, Lily; Assamagan, Ketevi; Astbury, Alan; Astvatsatourov, Anatoli; Atoian, Grigor; Aubert, Bernard; Auerbach, Benjamin; Auge, Etienne; Augsten, Kamil; Aurousseau, Mathieu; Austin, Nicholas; Avolio, Giuseppe; Avramidou, Rachel Maria; Axen, David; Ay, Cano; Azuelos, Georges; Azuma, Yuya; Baak, Max; Baccaglioni, Giuseppe; Bacci, Cesare; Bach, Andre; Bachacou, Henri; Bachas, Konstantinos; Bachy, Gerard; Backes, Moritz; Backhaus, Malte; Badescu, Elisabeta; Bagnaia, Paolo; Bahinipati, Seema; Bai, Yu; Bailey, David; Bain, Travis; Baines, John; Baker, Oliver Keith; Baker, Mark; Baker, Sarah; Baltasar Dos Santos Pedrosa, Fernando; Banas, Elzbieta; Banerjee, Piyali; Banerjee, Swagato; Banfi, Danilo; Bangert, Andrea Michelle; Bansal, Vikas; Bansil, Hardeep Singh; Barak, Liron; Baranov, Sergei; Barashkou, Andrei; Barbaro Galtieri, Angela; Barber, Tom; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Bardin, Dmitri; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnett, Bruce; Barnett, Michael; Baroncelli, Antonio; Barone, Gaetano; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Barrillon, Pierre; Bartoldus, Rainer; Barton, Adam Edward; Bartsch, Detlef; Bartsch, Valeria; Bates, Richard; Batkova, Lucia; Batley, Richard; Battaglia, Andreas; Battistin, Michele; Battistoni, Giuseppe; Bauer, Florian; Bawa, Harinder Singh; Beare, Brian; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Hans Peter; Beckingham, Matthew; Becks, Karl-Heinz; Beddall, Andrew; Beddall, Ayda; Bedikian, Sourpouhi; Bednyakov, Vadim; Bee, Christopher; Begel, Michael; Behar Harpaz, Silvia; Behera, Prafulla; Beimforde, Michael; Belanger-Champagne, Camille; Bell, Paul; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellina, Francesco; Bellomo, Massimiliano; Belloni, Alberto; Beloborodova, Olga; Belotskiy, Konstantin; Beltramello, Olga; Ben Ami, Sagi; Benary, Odette; Benchekroun, Driss; Benchouk, Chafik; Bendel, Markus; Benedict, Brian Hugues; Benekos, Nektarios; Benhammou, Yan; Benjamin, Douglas; Benoit, Mathieu; Bensinger, James; Benslama, Kamal; Bentvelsen, Stan; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Berglund, Elina; Beringer, Jürg; Bernardet, Karim; Bernat, Pauline; Bernhard, Ralf; Bernius, Catrin; Berry, Tracey; Bertin, Antonio; Bertinelli, Francesco; Bertolucci, Federico; Besana, Maria Ilaria; Besson, Nathalie; Bethke, Siegfried; Bhimji, Wahid; Bianchi, Riccardo-Maria; Bianco, Michele; Biebel, Otmar; Bieniek, Stephen Paul; Biesiada, Jed; Biglietti, Michela; Bilokon, Halina; Bindi, Marcello; Binet, Sebastien; Bingul, Ahmet; Bini, Cesare; Biscarat, Catherine; Bitenc, Urban; Black, Kevin; Blair, Robert; Blanchard, Jean-Baptiste; Blanchot, Georges; Blazek, Tomas; Blocker, Craig; Blocki, Jacek; Blondel, Alain; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bobrovnikov, Victor; Bocchetta, Simona Serena; Bocci, Andrea; Boddy, Christopher Richard; Boehler, Michael; Boek, Jennifer; Boelaert, Nele; Böser, Sebastian; Bogaerts, Joannes Andreas; Bogdanchikov, Alexander; Bogouch, Andrei; Bohm, Christian; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Bolnet, Nayanka Myriam; Bona, Marcella; Bondarenko, Valery; Boonekamp, Maarten; Boorman, Gary; Booth, Chris; Bordoni, Stefania; Borer, Claudia; Borisov, Anatoly; Borissov, Guennadi; Borjanovic, Iris; Borroni, Sara; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boterenbrood, Hendrik; Botterill, David; Bouchami, Jihene; Boudreau, Joseph; Bouhova-Thacker, Evelina Vassileva; Boulahouache, Chaouki; Bourdarios, Claire; Bousson, Nicolas; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozhko, Nikolay; Bozovic-Jelisavcic, Ivanka; Bracinik, Juraj; Braem, André; Branchini, Paolo; Brandenburg, George; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brelier, Bertrand; Bremer, Johan; Brenner, Richard; Bressler, Shikma; Breton, Dominique; Britton, Dave; Brochu, Frederic; Brock, Ian; Brock, Raymond; Brodbeck, Timothy; Brodet, Eyal; Broggi, Francesco; Bromberg, Carl; Brooijmans, Gustaaf; Brooks, William; Brown, Gareth; Brown, Heather; Brubaker, Erik; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Brunet, Sylvie; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Buanes, Trygve; Bucci, Francesca; Buchanan, James; Buchanan, Norman; Buchholz, Peter; Buckingham, Ryan; Buckley, Andrew; Buda, Stelian Ioan; Budagov, Ioulian; Budick, Burton; Büscher, Volker; Bugge, Lars; Buira-Clark, Daniel; Bulekov, Oleg; Bunse, Moritz; Buran, Torleiv; Burckhart, Helfried; Burdin, Sergey; Burgess, Thomas; Burke, Stephen; Busato, Emmanuel; Bussey, Peter; Buszello, Claus-Peter; Butin, François; Butler, Bart; Butler, John; Buttar, Craig; Butterworth, Jonathan; Buttinger, William; Byatt, Tom; Cabrera Urbán, Susana; Caforio, Davide; Cakir, Orhan; Calafiura, Paolo; Calderini, Giovanni; Calfayan, Philippe; Calkins, Robert; Caloba, Luiz; Caloi, Rita; Calvet, David; Calvet, Samuel; Camacho Toro, Reina; Camard, Arnaud; Camarri, Paolo; Cambiaghi, Mario; Cameron, David; Cammin, Jochen; Campana, Simone; Campanelli, Mario; Canale, Vincenzo; Canelli, Florencia; Canepa, Anadi; Cantero, Josu; Capasso, Luciano; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capriotti, Daniele; Capua, Marcella; Caputo, Regina; Caramarcu, Costin; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Bryan; Caron, Sascha; Carrillo Montoya, German D; Carter, Antony; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Cascella, Michele; Caso, Carlo; Castaneda Hernandez, Alfredo Martin; Castaneda-Miranda, Elizabeth; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Cataldi, Gabriella; Cataneo, Fernando; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Cattani, Giordano; Caughron, Seth; Cauz, Diego; Cavalleri, Pietro; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Cazzato, Antonio; Ceradini, Filippo; Santiago Cerqueira, Augusto; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cetin, Serkant Ali; Cevenini, Francesco; Chafaq, Aziz; Chakraborty, Dhiman; Chan, Kevin; Chapleau, Bertrand; Chapman, John Derek; Chapman, John Wehrley; Chareyre, Eve; Charlton, Dave; Chavda, Vikash; Cheatham, Susan; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chelstowska, Magda Anna; Chen, Chunhui; Chen, Hucheng; Chen, Li; Chen, Shenjian; Chen, Tingyang; Chen, Xin; Cheng, Shaochen; Cheplakov, Alexander; Chepurnov, Vladimir; Cherkaoui El Moursli, Rajaa; Chernyatin, Valeriy; Cheu, Elliott; Cheung, Sing-Leung; Chevalier, Laurent; Chiefari, Giovanni; Chikovani, Leila; Childers, John Taylor; Chilingarov, Alexandre; Chiodini, Gabriele; Chislett, Rebecca Thalatta; Chizhov, Mihail; Choudalakis, Georgios; Chouridou, Sofia; Christidi, Illectra-Athanasia; Christov, Asen; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Ciapetti, Guido; Ciba, Krzysztof; Ciftci, Abbas Kenan; Ciftci, Rena; Cinca, Diane; Cindro, Vladimir; Ciobotaru, Matei Dan; Ciocca, Claudia; Ciocio, Alessandra; Cirilli, Manuela; Ciubancan, Mihai; Clark, Allan G; Clark, Philip; Cleland, Bill; Clemens, Jean-Claude; Clement, Benoit; Clement, Christophe; Clifft, Roger; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H; Coe, Paul; Cogan, Joshua Godfrey; Coggeshall, James; Cogneras, Eric; Cojocaru, Claudiu; Colas, Jacques; Colijn, Auke-Pieter; Collard, Caroline; Collins, Neil; Collins-Tooth, Christopher; Collot, Johann; Colon, German; Conde Muiño, Patricia; Coniavitis, Elias; Conidi, Maria Chiara; Consonni, Michele; Consorti, Valerio; Constantinescu, Serban; Conta, Claudio; Conventi, Francesco; Cook, James; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Cooper-Smith, Neil; Copic, Katherine; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Costin, Tudor; Côté, David; Coura Torres, Rodrigo; Courneyea, Lorraine; Cowan, Glen; Cowden, Christopher; Cox, Brian; Cranmer, Kyle; Crescioli, Francesco; Cristinziani, Markus; Crosetti, Giovanni; Crupi, Roberto; Crépé-Renaudin, Sabine; Cuciuc, Constantin-Mihai; Cuenca Almenar, Cristóbal; Cuhadar Donszelmann, Tulay; Cuneo, Stefano; Curatolo, Maria; Curtis, Chris; Cwetanski, Peter; Czirr, Hendrik; Czyczula, Zofia; D'Auria, Saverio; D'Onofrio, Monica; D'Orazio, Alessia; Da Rocha Gesualdi Mello, Aline; Da Silva, Paulo Vitor; Da Via, Cinzia; Dabrowski, Wladyslaw; Dahlhoff, Andrea; Dai, Tiesheng; Dallapiccola, Carlo; Dam, Mogens; Dameri, Mauro; Damiani, Daniel; Danielsson, Hans Olof; Dannheim, Dominik; Dao, Valerio; Darbo, Giovanni; Darlea, Georgiana Lavinia; Daum, Cornelis; Dauvergne, Jean-Pierre; Davey, Will; Davidek, Tomas; Davidson, Nadia; Davidson, Ruth; Davies, Eleanor; Davies, Merlin; Davison, Adam; Davygora, Yuriy; Dawe, Edmund; Dawson, Ian; Dawson, John; Daya, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Castro, Stefano; De Castro Faria Salgado, Pedro; De Cecco, Sandro; de Graat, Julien; De Groot, Nicolo; de Jong, Paul; De La Taille, Christophe; De la Torre, Hector; De Lotto, Barbara; De Mora, Lee; De Nooij, Lucie; De Oliveira Branco, Miguel; De Pedis, Daniele; de Saintignon, Paul; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; Dean, Simon; Dedovich, Dmitri; Degenhardt, James; Dehchar, Mohamed; Deile, Mario; Del Papa, Carlo; Del Peso, Jose; Del Prete, Tarcisio; Dell'Acqua, Andrea; Dell'Asta, Lidia; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delpierre, Pierre; Delruelle, Nicolas; Delsart, Pierre-Antoine; Deluca, Carolina; Demers, Sarah; Demichev, Mikhail; Demirkoz, Bilge; Deng, Jianrong; Denisov, Sergey; Derendarz, Dominik; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Devetak, Erik; Deviveiros, Pier-Olivier; Dewhurst, Alastair; DeWilde, Burton; Dhaliwal, Saminder; Dhullipudi, Ramasudhakar; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Luise, Silvestro; Di Mattia, Alessandro; Di Micco, Biagio; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Diaz, Marco Aurelio; Diblen, Faruk; Diehl, Edward; Dieli, Michele Vincenzo; Dietl, Hans; Dietrich, Janet; Dietzsch, Thorsten; Diglio, Sara; Dindar Yagci, Kamile; Dingfelder, Jochen; Dionisi, Carlo; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djilkibaev, Rashid; Djobava, Tamar; Barros do Vale, Maria Aline; Do Valle Wemans, André; Doan, Thi Kieu Oanh; Dobbs, Matt; Dobinson, Robert; Dobos, Daniel; Dobson, Ellie; Dobson, Marc; Dodd, Jeremy; Dogan, Ozgen Berkol; Doglioni, Caterina; Doherty, Tom; Doi, Yoshikuni; Dolejsi, Jiri; Dolenc, Irena; Dolezal, Zdenek; Dolgoshein, Boris; Dohmae, Takeshi; Donadelli, Marisilvia; Donega, Mauro; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dos Anjos, Andre; Dosil, Mireia; Dotti, Andrea; Dova, Maria-Teresa; Dowell, John; Doxiadis, Alexander; Doyle, Tony; Drasal, Zbynek; Drees, Jürgen; Dressnandt, Nandor; Drevermann, Hans; Driouichi, Chafik; Dris, Manolis; Dubbert, Jörg; Dubbs, Tim; Dube, Sourabh; Duchovni, Ehud; Duckeck, Guenter; Dudarev, Alexey; Dudziak, Fanny; Dührssen, Michael; Duerdoth, Ian; Duflot, Laurent; Dufour, Marc-Andre; Dunford, Monica; Duran Yildiz, Hatice; Duxfield, Robert; Dwuznik, Michal; Dydak, Friedrich; Dzahini, Daniel; Düren, Michael; Ebenstein, William; Ebke, Johannes; Eckert, Simon; Eckweiler, Sebastian; Edmonds, Keith; Edwards, Clive; Edwards, Nicholas Charles; Ehrenfeld, Wolfgang; Ehrich, Thies; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Eisenhandler, Eric; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Ellis, Katherine; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Ely, Robert; Emeliyanov, Dmitry; Engelmann, Roderich; Engl, Albert; Epp, Brigitte; Eppig, Andrew; Erdmann, Johannes; Ereditato, Antonio; Eriksson, Daniel; Ernst, Jesse; Ernst, Michael; Ernwein, Jean; Errede, Deborah; Errede, Steven; Ertel, Eugen; Escalier, Marc; Escobar, Carlos; Espinal Curull, Xavier; Esposito, Bellisario; Etienne, Francois; Etienvre, Anne-Isabelle; Etzion, Erez; Evangelakou, Despoina; Evans, Hal; Fabbri, Laura; Fabre, Caroline; Fakhrutdinov, Rinat; Falciano, Speranza; Falou, Alain; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farley, Jason; Farooque, Trisha; Farrington, Sinead; Farthouat, Philippe; Fassnacht, Patrick; Fassouliotis, Dimitrios; Fatholahzadeh, Baharak; Favareto, Andrea; Fayard, Louis; Fazio, Salvatore; Febbraro, Renato; Federic, Pavol; Fedin, Oleg; Fedorko, Ivan; Fedorko, Woiciech; Fehling-Kaschek, Mirjam; Feligioni, Lorenzo; Fellmann, Denis; Felzmann, Ulrich; Feng, Cunfeng; Feng, Eric; Fenyuk, Alexander; Ferencei, Jozef; Ferland, Jonathan; Fernando, Waruna; Ferrag, Samir; Ferrando, James; Ferrara, Valentina; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferrer, Antonio; Ferrer, Maria Lorenza; Ferrere, Didier; Ferretti, Claudio; Ferretto Parodi, Andrea; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filippas, Anastasios; Filthaut, Frank; Fincke-Keeler, Margret; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Gordon; Fischer, Peter; Fisher, Matthew; Fisher, Steve; Flechl, Martin; Fleck, Ivor; Fleckner, Johanna; Fleischmann, Philipp; Fleischmann, Sebastian; Flick, Tobias; Flores Castillo, Luis; Flowerdew, Michael; Föhlisch, Florian; Fokitis, Manolis; Fonseca Martin, Teresa; Forbush, David Alan; Formica, Andrea; Forti, Alessandra; Fortin, Dominique; Foster, Joe; Fournier, Daniel; Foussat, Arnaud; Fowler, Andrew; Fowler, Ken; Fox, Harald; Francavilla, Paolo; Franchino, Silvia; Francis, David; Frank, Tal; Franklin, Melissa; Franz, Sebastien; Fraternali, Marco; Fratina, Sasa; French, Sky; Froeschl, Robert; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gadfort, Thomas; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Gallas, Elizabeth; Gallas, Manuel; Gallo, Valentina Santina; Gallop, Bruce; Gallus, Petr; Galyaev, Eugene; Gan, KK; Gao, Yongsheng; Gapienko, Vladimir; Gaponenko, Andrei; Garberson, Ford; Garcia-Sciveres, Maurice; García, Carmen; García Navarro, José Enrique; Gardner, Robert; Garelli, Nicoletta; Garitaonandia, Hegoi; Garonne, Vincent; Garvey, John; Gatti, Claudio; Gaudio, Gabriella; Gaumer, Olivier; Gaur, Bakul; Gauthier, Lea; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gayde, Jean-Christophe; Gazis, Evangelos; Ge, Peng; Gee, Norman; Geerts, Daniël Alphonsus Adrianus; Geich-Gimbel, Christoph; Gellerstedt, Karl; Gemme, Claudia; Gemmell, Alistair; Genest, Marie-Hélène; Gentile, Simonetta; George, Matthias; George, Simon; Gerlach, Peter; Gershon, Avi; Geweniger, Christoph; Ghazlane, Hamid; Ghez, Philippe; Ghodbane, Nabil; Giacobbe, Benedetto; Giagu, Stefano; Giakoumopoulou, Victoria; Giangiobbe, Vincent; Gianotti, Fabiola; Gibbard, Bruce; Gibson, Adam; Gibson, Stephen; Gilbert, Laura; Gilchriese, Murdock; Gilewsky, Valentin; Gillberg, Dag; Gillman, Tony; Gingrich, Douglas; Ginzburg, Jonatan; Giokaris, Nikos; Giordano, Raffaele; Giorgi, Francesco Michelangelo; Giovannini, Paola; Giraud, Pierre-Francois; Giugni, Danilo; Giunta, Michele; Giusti, Paolo; Gjelsten, Børge Kile; Gladilin, Leonid; Glasman, Claudia; Glatzer, Julian; Glazov, Alexandre; Glitza, Karl-Walter; Glonti, George; Godfrey, Jennifer; Godlewski, Jan; Goebel, Martin; Göpfert, Thomas; Goeringer, Christian; Gössling, Claus; Göttfert, Tobias; Goldfarb, Steven; Goldin, Daniel; Golling, Tobias; Golovnia, Serguei; Gomes, Agostinho; Gomez Fajardo, Luz Stella; Gonçalo, Ricardo; Goncalves Pinto Firmino Da Costa, Joao; Gonella, Laura; Gonidec, Allain; Gonzalez, Saul; González de la Hoz, Santiago; Gonzalez Silva, Laura; Gonzalez-Sevilla, Sergio; Goodson, Jeremiah Jet; Goossens, Luc; Gorbounov, Petr Andreevich; Gordon, Howard; Gorelov, Igor; Gorfine, Grant; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Gorokhov, Serguei; Goryachev, Vladimir; Gosdzik, Bjoern; Gosselink, Martijn; Gostkin, Mikhail Ivanovitch; Gouanère, Michel; Gough Eschrich, Ivo; Gouighri, Mohamed; Goujdami, Driss; Goulette, Marc Phillippe; Goussiou, Anna; Goy, Corinne; Grabowska-Bold, Iwona; Grabski, Varlen; Grafström, Per; Grah, Christian; Grahn, Karl-Johan; Grancagnolo, Francesco; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Grau, Nathan; Gray, Heather; Gray, Julia Ann; Graziani, Enrico; Grebenyuk, Oleg; Greenfield, Debbie; Greenshaw, Timothy; Greenwood, Zeno Dixon; Gregor, Ingrid-Maria; Grenier, Philippe; Griesmayer, Erich; Griffiths, Justin; Grigalashvili, Nugzar; Grillo, Alexander; Grinstein, Sebastian; Grishkevich, Yaroslav; Grivaz, Jean-Francois; Grognuz, Joel; Groh, Manfred; Gross, Eilam; Grosse-Knetter, Joern; Groth-Jensen, Jacob; Grybel, Kai; Guarino, Victor; Guest, Daniel; Guicheney, Christophe; Guida, Angelo; Guillemin, Thibault; Guindon, Stefan; Guler, Hulya; Gunther, Jaroslav; Guo, Bin; Guo, Jun; Gupta, Ambreesh; Gusakov, Yury; Gushchin, Vladimir; Gutierrez, Andrea; Gutierrez, Phillip; Guttman, Nir; Gutzwiller, Olivier; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haas, Stefan; Haber, Carl; Hackenburg, Robert; Hadavand, Haleh Khani; Hadley, David; Haefner, Petra; Hahn, Ferdinand; Haider, Stefan; Hajduk, Zbigniew; Hakobyan, Hrachya; Haller, Johannes; Hamacher, Klaus; Hamal, Petr; Hamilton, Andrew; Hamilton, Samuel; Han, Hongguang; Han, Liang; Hanagaki, Kazunori; Hance, Michael; Handel, Carsten; Hanke, Paul; Hansen, John Renner; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, Peter Henrik; Hansson, Per; Hara, Kazuhiko; Hare, Gabriel; Harenberg, Torsten; Harkusha, Siarhei; Harper, Devin; Harrington, Robert; Harris, Orin; Harrison, Karl; Hartert, Jochen; Hartjes, Fred; Haruyama, Tomiyoshi; Harvey, Alex; Hasegawa, Satoshi; Hasegawa, Yoji; Hassani, Samira; Hatch, Mark; Hauff, Dieter; Haug, Sigve; Hauschild, Michael; Hauser, Reiner; Havranek, Miroslav; Hawes, Brian; Hawkes, Christopher; Hawkings, Richard John; Hawkins, Donovan; Hayakawa, Takashi; Hayden, Daniel; Hayward, Helen; Haywood, Stephen; Hazen, Eric; He, Mao; Head, Simon; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heine, Kristin; Heinemann, Beate; Heisterkamp, Simon; Helary, Louis; Heldmann, Michael; Heller, Mathieu; Hellman, Sten; Helsens, Clement; Henderson, Robert; Henke, Michael; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Henry-Couannier, Frédéric; Hensel, Carsten; Henß, Tobias; Medina Hernandez, Carlos; Hernández Jiménez, Yesenia; Herrberg, Ruth; Hershenhorn, Alon David; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hessey, Nigel; Hidvegi, Attila; Higón-Rodriguez, Emilio; Hill, Daniel; Hill, John; Hill, Norman; Hiller, Karl Heinz; Hillert, Sonja; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hirose, Minoru; Hirsch, Florian; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoffman, Julia; Hoffmann, Dirk; Hohlfeld, Marc; Holder, Martin; Holmes, Alan; Holmgren, Sven-Olof; Holy, Tomas; Holzbauer, Jenny; Homma, Yasuhiro; Hong, Tae Min; Hooft van Huysduynen, Loek; Horazdovsky, Tomas; Horn, Claus; Horner, Stephan; Horton, Katherine; Hostachy, Jean-Yves; Hou, Suen; Houlden, Michael; Hoummada, Abdeslam; Howarth, James; Howell, David; Hristova, Ivana; Hrivnac, Julius; Hruska, Ivan; Hryn'ova, Tetiana; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Huang, Guang Shun; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Hughes-Jones, Richard; Huhtinen, Mika; Hurst, Peter; Hurwitz, Martina; Husemann, Ulrich; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibbotson, Michael; Ibragimov, Iskander; Ichimiya, Ryo; Iconomidou-Fayard, Lydia; Idarraga, John; Idzik, Marek; Iengo, Paolo; Igonkina, Olga; Ikegami, Yoichi; Ikeno, Masahiro; Ilchenko, Yuri; Iliadis, Dimitrios; Imbault, Didier; Imhaeuser, Martin; Imori, Masatoshi; Ince, Tayfun; Inigo-Golfin, Joaquin; Ioannou, Pavlos; Iodice, Mauro; Ionescu, Gelu; Irles Quiles, Adrian; Ishii, Koji; Ishikawa, Akimasa; Ishino, Masaya; Ishmukhametov, Renat; Issever, Cigdem; Istin, Serhat; Itoh, Yuki; Ivashin, Anton; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jackson, Brett; Jackson, John; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakubek, Jan; Jana, Dilip; Jankowski, Ernest; Jansen, Eric; Jantsch, Andreas; Janus, Michel; Jarlskog, Göran; Jeanty, Laura; Jelen, Kazimierz; Jen-La Plante, Imai; Jenni, Peter; Jeremie, Andrea; Jež, Pavel; Jézéquel, Stéphane; Jha, Manoj Kumar; Ji, Haoshuang; Ji, Weina; Jia, Jiangyong; Jiang, Yi; Jimenez Belenguer, Marcos; Jin, Ge; Jin, Shan; Jinnouchi, Osamu; Joergensen, Morten Dam; Joffe, David; Johansen, Lars; Johansen, Marianne; Johansson, Erik; Johansson, Per; Johnert, Sebastian; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tegid; Jones, Tim; Jonsson, Ove; Joram, Christian; Jorge, Pedro; Joseph, John; Ju, Xiangyang; Juranek, Vojtech; Jussel, Patrick; Kabachenko, Vasily; Kabana, Sonja; Kaci, Mohammed; Kaczmarska, Anna; Kadlecik, Peter; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kaiser, Steffen; Kajomovitz, Enrique; Kalinin, Sergey; Kalinovskaya, Lidia; Kama, Sami; Kanaya, Naoko; Kaneda, Michiru; Kanno, Takayuki; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kaplon, Jan; Kar, Deepak; Karagoz, Muge; Karnevskiy, Mikhail; Karr, Kristo; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kasmi, Azzedine; Kass, Richard; Kastanas, Alex; Kataoka, Mayuko; Kataoka, Yousuke; Katsoufis, Elias; Katzy, Judith; Kaushik, Venkatesh; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kayl, Manuel; Kazanin, Vassili; Kazarinov, Makhail; Keates, James Robert; Keeler, Richard; Kehoe, Robert; Keil, Markus; Kekelidze, George; Kelly, Marc; Kennedy, John; Kenney, Christopher John; Kenyon, Mike; Kepka, Oldrich; Kerschen, Nicolas; Kerševan, Borut Paul; Kersten, Susanne; Kessoku, Kohei; Ketterer, Christian; Keung, Justin; Khakzad, Mohsen; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharchenko, Dmitri; Khodinov, Alexander; Kholodenko, Anatoli; Khomich, Andrei; Khoo, Teng Jian; Khoriauli, Gia; Khoroshilov, Andrey; Khovanskiy, Nikolai; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kim, Hyeon Jin; Kim, Min Suk; Kim, Peter; Kim, Shinhong; Kimura, Naoki; Kind, Oliver; King, Barry; King, Matthew; King, Robert Steven Beaufoy; Kirk, Julie; Kirsch, Guillaume; Kirsch, Lawrence; Kiryunin, Andrey; Kisielewska, Danuta; Kittelmann, Thomas; Kiver, Andrey; Kiyamura, Hironori; Kladiva, Eduard; Klaiber-Lodewigs, Jonas; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klemetti, Miika; Klier, Amit; Klimentov, Alexei; Klingenberg, Reiner; Klinkby, Esben; Klioutchnikova, Tatiana; Klok, Peter; Klous, Sander; Kluge, Eike-Erik; Kluge, Thomas; Kluit, Peter; Kluth, Stefan; Kneringer, Emmerich; Knobloch, Juergen; Knoops, Edith; Knue, Andrea; Ko, Byeong Rok; Kobayashi, Tomio; Kobel, Michael; Kocian, Martin; Kocnar, Antonin; Kodys, Peter; Köneke, Karsten; König, Adriaan; Koenig, Sebastian; Köpke, Lutz; Koetsveld, Folkert; Koevesarki, Peter; Koffas, Thomas; Koffeman, Els; Kohn, Fabian; Kohout, Zdenek; Kohriki, Takashi; Koi, Tatsumi; Kokott, Thomas; Kolachev, Guennady; Kolanoski, Hermann; Kolesnikov, Vladimir; Koletsou, Iro; Koll, James; Kollar, Daniel; Kollefrath, Michael; Kolya, Scott; Komar, Aston; Komaragiri, Jyothsna Rani; Komori, Yuto; Kondo, Takahiko; Kono, Takanori; Kononov, Anatoly; Konoplich, Rostislav; Konstantinidis, Nikolaos; Kootz, Andreas; Koperny, Stefan; Kopikov, Sergey; Korcyl, Krzysztof; Kordas, Kostantinos; Koreshev, Victor; Korn, Andreas; Korol, Aleksandr; Korolkov, Ilya; Korolkova, Elena; Korotkov, Vladislav; Kortner, Oliver; Kortner, Sandra; Kostyukhin, Vadim; Kotamäki, Miikka Juhani; Kotov, Sergey; Kotov, Vladislav; Kotwal, Ashutosh; Kourkoumelis, Christine; Kouskoura, Vasiliki; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kral, Vlastimil; Kramarenko, Viktor; Kramberger, Gregor; Krasel, Olaf; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, James; Kreisel, Arik; Krejci, Frantisek; Kretzschmar, Jan; Krieger, Nina; Krieger, Peter; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Kruker, Tobias; Krumshteyn, Zinovii; Kruth, Andre; Kubota, Takashi; Kuehn, Susanne; Kugel, Andreas; Kuhl, Thorsten; Kuhn, Dietmar; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kummer, Christian; Kuna, Marine; Kundu, Nikhil; Kunkle, Joshua; Kupco, Alexander; Kurashige, Hisaya; Kurata, Masakazu; Kurochkin, Yurii; Kus, Vlastimil; Kuykendall, William; Kuze, Masahiro; Kuzhir, Polina; Kvasnicka, Ondrej; Kvita, Jiri; Kwee, Regina; La Rosa, Alessandro; La Rotonda, Laura; Labarga, Luis; Labbe, Julien; Lablak, Said; Lacasta, Carlos; Lacava, Francesco; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Rémi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Laisne, Emmanuel; Lamanna, Massimo; Lampen, Caleb; Lampl, Walter; Lancon, Eric; Landgraf, Ulrich; Landon, Murrough; Landsman, Hagar; Lane, Jenna; Lange, Clemens; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Lapin, Vladimir; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Larionov, Anatoly; Larner, Aimee; Lasseur, Christian; Lassnig, Mario; Lau, Wing; Laurelli, Paolo; Lavorato, Antonia; Lavrijsen, Wim; Laycock, Paul; Lazarev, Alexandre; Lazzaro, Alfio; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Maner, Christophe; Le Menedeu, Eve; Lebedev, Alexander; Lebel, Céline; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Hurng-Chun; Lee, Jason; Lee, Shih-Chang; Lee, Lawrence; Lefebvre, Michel; Legendre, Marie; Leger, Annie; LeGeyt, Benjamin; Legger, Federica; Leggett, Charles; Lehmacher, Marc; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leite, Marco Aurelio Lisboa; Leitner, Rupert; Lellouch, Daniel; Leltchouk, Mikhail; Lendermann, Victor; Leney, Katharine; Lenz, Tatiana; Lenzen, Georg; Lenzi, Bruno; Leonhardt, Kathrin; Leontsinis, Stefanos; Leroy, Claude; Lessard, Jean-Raphael; Lesser, Jonas; Lester, Christopher; Leung Fook Cheong, Annabelle; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Levitski, Mikhail; Lewandowska, Marta; Lewis, Adrian; Lewis, George; Leyko, Agnieszka; Leyton, Michael; Li, Bo; Li, Haifeng; Li, Shu; Li, Xuefei; Liang, Zhihua; Liang, Zhijun; Liberti, Barbara; Lichard, Peter; Lichtnecker, Markus; Lie, Ki; Liebig, Wolfgang; Lifshitz, Ronen; Lilley, Joseph; Limbach, Christian; Limosani, Antonio; Limper, Maaike; Lin, Simon; Linde, Frank; Linnemann, James; Lipeles, Elliot; Lipinsky, Lukas; Lipniacka, Anna; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Chuanlei; Liu, Dong; Liu, Hao; Liu, Jianbei; Liu, Minghui; Liu, Shengli; Liu, Yanwen; Livan, Michele; Livermore, Sarah; Lleres, Annick; Llorente Merino, Javier; Lloyd, Stephen; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Lockwitz, Sarah; Loddenkoetter, Thomas; Loebinger, Fred; Loginov, Andrey; Loh, Chang Wei; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Loken, James; Lombardo, Vincenzo Paolo; Long, Robin Eamonn; Lopes, Lourenco; Lopez Mateos, David; Losada, Marta; Loscutoff, Peter; Lo Sterzo, Francesco; Losty, Michael; Lou, Xinchou; Lounis, Abdenour; Loureiro, Karina; Love, Jeremy; Love, Peter; Lowe, Andrew; Lu, Feng; Lu, Liang; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Ludwig, Andreas; Ludwig, Dörthe; Ludwig, Inga; Ludwig, Jens; Luehring, Frederick; Luijckx, Guy; Lumb, Debra; Luminari, Lamberto; Lund, Esben; Lund-Jensen, Bengt; Lundberg, Björn; Lundberg, Johan; Lundquist, Johan; Lungwitz, Matthias; Lupi, Anna; Lutz, Gerhard; Lynn, David; Lys, Jeremy; Lytken, Else; Ma, Hong; Ma, Lian Liang; Macana Goia, Jorge Andres; Maccarrone, Giovanni; Macchiolo, Anna; Maček, Boštjan; Machado Miguens, Joana; Mackeprang, Rasmus; Madaras, Ronald; Mader, Wolfgang; Maenner, Reinhard; Maeno, Tadashi; Mättig, Peter; Mättig, Stefan; Magalhaes Martins, Paulo Jorge; Magnoni, Luca; Magradze, Erekle; Mahalalel, Yair; Mahboubi, Kambiz; Mahout, Gilles; Maiani, Camilla; Maidantchik, Carmen; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makovec, Nikola; Mal, Prolay; Malecki, Pawel; Malecki, Piotr; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mameghani, Raphael; Mamuzic, Judita; Manabe, Atsushi; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Mangeard, Pierre-Simon; Manjavidze, Ioseb; Mann, Alexander; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Manz, Andreas; Mapelli, Alessandro; Mapelli, Livio; March, Luis; Marchand, Jean-Francois; Marchese, Fabrizio; Marchiori, Giovanni; Marcisovsky, Michal; Marin, Alexandru; Marino, Christopher; Marroquim, Fernando; Marshall, Robin; Marshall, Zach; Martens, Kalen; Marti-Garcia, Salvador; Martin, Andrew; Martin, Brian; Martin, Brian Thomas; Martin, Franck Francois; Martin, Jean-Pierre; Martin, Philippe; Martin, Tim; Martin dit Latour, Bertrand; Martinez, Mario; Martinez Outschoorn, Verena; Martyniuk, Alex; Marx, Marilyn; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Maß, Martin; Massa, Ignazio; Massaro, Graziano; Massol, Nicolas; Mastrandrea, Paolo; Mastroberardino, Anna; Masubuchi, Tatsuya; Mathes, Markus; Matricon, Pierre; Matsumoto, Hiroshi; Matsunaga, Hiroyuki; Matsushita, Takashi; Mattravers, Carly; Maugain, Jean-Marie; Maxfield, Stephen; Maximov, Dmitriy; May, Edward; Mayne, Anna; Mazini, Rachid; Mazur, Michael; Mazzanti, Marcello; Mazzoni, Enrico; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCarthy, Tom; McCubbin, Norman; McFarlane, Kenneth; Mcfayden, Josh; McGlone, Helen; Mchedlidze, Gvantsa; McLaren, Robert Andrew; Mclaughlan, Tom; McMahon, Steve; McPherson, Robert; Meade, Andrew; Mechnich, Joerg; Mechtel, Markus; Medinnis, Mike; Meera-Lebbai, Razzak; Meguro, Tatsuma; Mehdiyev, Rashid; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meinhardt, Jens; Meirose, Bernhard; Melachrinos, Constantinos; Mellado Garcia, Bruce Rafael; Mendoza Navas, Luis; Meng, Zhaoxia; Mengarelli, Alberto; Menke, Sven; Menot, Claude; Meoni, Evelin; Mercurio, Kevin Michael; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meuser, Stefan; Meyer, Carsten; Meyer, Jean-Pierre; Meyer, Jochen; Meyer, Joerg; Meyer, Thomas Christian; Meyer, W Thomas; Miao, Jiayuan; Michal, Sebastien; Micu, Liliana; Middleton, Robin; Miele, Paola; Migas, Sylwia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Miller, David; Miller, Robert; Mills, Bill; Mills, Corrinne; Milov, Alexander; Milstead, David; Milstein, Dmitry; Minaenko, Andrey; Miñano, Mercedes; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mirabelli, Giovanni; Miralles Verge, Lluis; Misiejuk, Andrzej; Mitrevski, Jovan; Mitrofanov, Gennady; Mitsou, Vasiliki A; Mitsui, Shingo; Miyagawa, Paul; Miyazaki, Kazuki; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Mockett, Paul; Moed, Shulamit; Moeller, Victoria; Mönig, Klaus; Möser, Nicolas; Mohapatra, Soumya; Mohn, Bjarte; Mohr, Wolfgang; Mohrdieck-Möck, Susanne; Moisseev, Artemy; Moles-Valls, Regina; Molina-Perez, Jorge; Monk, James; Monnier, Emmanuel; Montesano, Simone; Monticelli, Fernando; Monzani, Simone; Moore, Roger; Moorhead, Gareth; Mora Herrera, Clemencia; Moraes, Arthur; Morais, Antonio; Morange, Nicolas; Morel, Julien; Morello, Gianfranco; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morii, Masahiro; Morin, Jerome; Morita, Youhei; Morley, Anthony Keith; Mornacchi, Giuseppe; Morone, Maria-Christina; Morozov, Sergey; Morris, John; Morvaj, Ljiljana; Moser, Hans-Guenther; Mosidze, Maia; Moss, Josh; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Mudrinic, Mihajlo; Mueller, Felix; Mueller, James; Mueller, Klemens; Müller, Thomas; Muenstermann, Daniel; Muijs, Sandra; Muir, Alex; Munwes, Yonathan; Murakami, Koichi; Murray, Bill; Mussche, Ido; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nadal, Jordi; Nagai, Koichi; Nagano, Kunihiro; Nagasaka, Yasushi; Nairz, Armin Michael; Nakahama, Yu; Nakamura, Koji; Nakano, Itsuo; Nanava, Gizo; Napier, Austin; Nash, Michael; Nation, Nigel; Nattermann, Till; Naumann, Thomas; Navarro, Gabriela; Neal, Homer; Nebot, Eduardo; Nechaeva, Polina; Negri, Andrea; Negri, Guido; Nektarijevic, Snezana; Nelson, Andrew; Nelson, Silke; Nelson, Timothy Knight; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Nesterov, Stanislav; Neubauer, Mark; Neusiedl, Andrea; Neves, Ricardo; Nevski, Pavel; Newman, Paul; Nguyen Thi Hong, Van; Nickerson, Richard; Nicolaidou, Rosy; Nicolas, Ludovic; Nicquevert, Bertrand; Niedercorn, Francois; Nielsen, Jason; Niinikoski, Tapio; Nikiforov, Andriy; Nikolaenko, Vladimir; Nikolaev, Kirill; Nikolic-Audit, Irena; Nikolopoulos, Konstantinos; Nilsen, Henrik; Nilsson, Paul; Ninomiya, Yoichi; Nisati, Aleandro; Nishiyama, Tomonori; Nisius, Richard; Nodulman, Lawrence; Nomachi, Masaharu; Nomidis, Ioannis; Nomoto, Hiroshi; Nordberg, Markus; Nordkvist, Bjoern; Norton, Peter; Novakova, Jana; Nozaki, Mitsuaki; Nožička, Miroslav; Nozka, Libor; Nugent, Ian Michael; Nuncio-Quiroz, Adriana-Elizabeth; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; Nyman, Tommi; O'Brien, Brendan Joseph; O'Neale, Steve; O'Neil, Dugan; O'Shea, Val; Oakham, Gerald; Oberlack, Horst; Ocariz, Jose; Ochi, Atsuhiko; Oda, Susumu; Odaka, Shigeru; Odier, Jerome; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohshima, Takayoshi; Ohshita, Hidetoshi; Ohska, Tokio Kenneth; Ohsugi, Takashi; Okada, Shogo; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olcese, Marco; Olchevski, Alexander; Oliveira, Miguel Alfonso; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olivito, Dominick; Olszewski, Andrzej; Olszowska, Jolanta; Omachi, Chihiro; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlov, Iliya; Oropeza Barrera, Cristina; Orr, Robert; Ortega, Eduardo; Osculati, Bianca; Ospanov, Rustem; Osuna, Carlos; Otero y Garzon, Gustavo; Ottersbach, John; Ouchrif, Mohamed; Ould-Saada, Farid; Ouraou, Ahmimed; Ouyang, Qun; Owen, Mark; Owen, Simon; Øye, Ola; Ozcan, Veysi Erkcan; Ozturk, Nurcan; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Paganis, Efstathios; Paige, Frank; Pajchel, Katarina; Palestini, Sandro; Pallin, Dominique; Palma, Alberto; Palmer, Jody; Pan, Yibin; Panagiotopoulou, Evgenia; Panes, Boris; Panikashvili, Natalia; Panitkin, Sergey; Pantea, Dan; Panuskova, Monika; Paolone, Vittorio; Papadelis, Aras; Papadopoulou, Theodora; Paramonov, Alexander; Park, Woochun; Parker, Andy; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passeri, Antonio; Pastore, Fernanda; Pastore, Francesca; Pásztor, Gabriella; Pataraia, Sophio; Patel, Nikhul; Pater, Joleen; Patricelli, Sergio; Pauly, Thilo; Pecsy, Martin; Pedraza Morales, Maria Isabel; Peleganchuk, Sergey; Peng, Haiping; Pengo, Ruggero; Penson, Alexander; Penwell, John; Perantoni, Marcelo; Perez, Kerstin; Perez Cavalcanti, Tiago; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perez Reale, Valeria; Peric, Ivan; Perini, Laura; Pernegger, Heinz; Perrino, Roberto; Perrodo, Pascal; Persembe, Seda; Peshekhonov, Vladimir; Peters, Onne; Petersen, Brian; Petersen, Jorgen; Petersen, Troels; Petit, Elisabeth; Petridis, Andreas; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Petschull, Dennis; Petteni, Michele; Pezoa, Raquel; Phan, Anna; Phillips, Alan; Phillips, Peter William; Piacquadio, Giacinto; Piccaro, Elisa; Piccinini, Maurizio; Pickford, Andrew; Piec, Sebastian Marcin; Piegaia, Ricardo; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinder, Alex; Pinfold, James; Ping, Jialun; Pinto, Belmiro; Pirotte, Olivier; Pizio, Caterina; Placakyte, Ringaile; Plamondon, Mathieu; Plano, Will; Pleier, Marc-Andre; Pleskach, Anatoly; Poblaguev, Andrei; Poddar, Sahill; Podlyski, Fabrice; Poggioli, Luc; Poghosyan, Tatevik; Pohl, Martin; Polci, Francesco; Polesello, Giacomo; Policicchio, Antonio; Polini, Alessandro; Poll, James; Polychronakos, Venetios; Pomarede, Daniel Marc; Pomeroy, Daniel; Pommès, Kathy; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Portell Bueso, Xavier; Porter, Robert; Posch, Christoph; Pospelov, Guennady; Pospisil, Stanislav; Potrap, Igor; Potter, Christina; Potter, Christopher; Poulard, Gilbert; Poveda, Joaquin; Prabhu, Robindra; Pralavorio, Pascal; Prasad, Srivas; Pravahan, Rishiraj; Prell, Soeren; Pretzl, Klaus Peter; Pribyl, Lukas; Price, Darren; Price, Lawrence; Price, Michael John; Prichard, Paul; Prieur, Damien; Primavera, Margherita; Prokofiev, Kirill; Prokoshin, Fedor; Protopopescu, Serban; Proudfoot, James; Prudent, Xavier; Przysiezniak, Helenka; Psoroulas, Serena; Ptacek, Elizabeth; Purdham, John; Purohit, Milind; Puzo, Patrick; Pylypchenko, Yuriy; Qian, Jianming; Qian, Zuxuan; Qin, Zhonghua; Quadt, Arnulf; Quarrie, David; Quayle, William; Quinonez, Fernando; Raas, Marcel; Radescu, Voica; Radics, Balint; Rador, Tonguc; Ragusa, Francesco; Rahal, Ghita; Rahimi, Amir; Rahm, David; Rajagopalan, Srinivasan; Rammensee, Michael; Rammes, Marcus; Ramstedt, Magnus; Randrianarivony, Koloina; Ratoff, Peter; Rauscher, Felix; Rauter, Emanuel; Raymond, Michel; Read, Alexander Lincoln; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Reichold, Armin; Reinherz-Aronis, Erez; Reinsch, Andreas; Reisinger, Ingo; Reljic, Dusan; Rembser, Christoph; Ren, Zhongliang; Renaud, Adrien; Renkel, Peter; Rensch, Bertram; Rescigno, Marco; Resconi, Silvia; Resende, Bernardo; Reznicek, Pavel; Rezvani, Reyhaneh; Richards, Alexander; Richter, Robert; Richter-Was, Elzbieta; Ridel, Melissa; Rieke, Stefan; Rijpstra, Manouk; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Rios, Ryan Randy; Riu, Imma; Rivoltella, Giancesare; Rizatdinova, Flera; Rizvi, Eram; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robinson, Mary; Robson, Aidan; Rocha de Lima, Jose Guilherme; Roda, Chiara; Roda Dos Santos, Denis; Rodier, Stephane; Rodriguez, Diego; Rodriguez Garcia, Yohany; Roe, Adam; Roe, Shaun; Røhne, Ole; Rojo, Victoria; Rolli, Simona; Romaniouk, Anatoli; Romanov, Victor; Romeo, Gaston; Romero Maltrana, Diego; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosbach, Kilian; Rose, Matthew; Rosenbaum, Gabriel; Rosenberg, Eli; Rosendahl, Peter Lundgaard; Rosselet, Laurent; Rossetti, Valerio; Rossi, Elvira; Rossi, Leonardo Paolo; Rossi, Lucio; Rotaru, Marina; Roth, Itamar; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexander; Rozen, Yoram; Ruan, Xifeng; Rubinskiy, Igor; Ruckert, Benjamin; Ruckstuhl, Nicole; Rud, Viacheslav; Rudolph, Gerald; Rühr, Frederik; Ruggieri, Federico; Ruiz-Martinez, Aranzazu; Rulikowska-Zarebska, Elzbieta; Rumiantsev, Viktor; Rumyantsev, Leonid; Runge, Kay; Runolfsson, Ogmundur; Rurikova, Zuzana; Rusakovich, Nikolai; Rust, Dave; Rutherfoord, John; Ruwiedel, Christoph; Ruzicka, Pavel; Ryabov, Yury; Ryadovikov, Vasily; Ryan, Patrick; Rybar, Martin; Rybkin, Grigori; Ryder, Nick; Rzaeva, Sevda; Saavedra, Aldo; Sadeh, Iftach; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sakamoto, Hiroshi; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvachua Ferrando, Belén; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sampsonidis, Dimitrios; Samset, Björn Hallvard; Sandaker, Heidi; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandoval, Tanya; Sandstroem, Rikard; Sandvoss, Stephan; Sankey, Dave; Sansoni, Andrea; Santamarina Rios, Cibran; Santoni, Claudio; Santonico, Rinaldo; Santos, Helena; Saraiva, João; Sarangi, Tapas; Sarkisyan-Grinbaum, Edward; Sarri, Francesca; Sartisohn, Georg; Sasaki, Osamu; Sasaki, Takashi; Sasao, Noboru; Satsounkevitch, Igor; Sauvage, Gilles; Sauvan, Jean-Baptiste; Savard, Pierre; Savinov, Vladimir; Savu, Dan Octavian; Savva, Panagiota; Sawyer, Lee; Saxon, David; Says, Louis-Pierre; Sbarra, Carla; Sbrizzi, Antonio; Scallon, Olivia; Scannicchio, Diana; Scarcella, Mark; Schaarschmidt, Jana; Schacht, Peter; Schäfer, Uli; Schaepe, Steffen; Schaetzel, Sebastian; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R. Dean; Schamov, Andrey; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Scherzer, Max; Schiavi, Carlo; Schieck, Jochen; Schioppa, Marco; Schlenker, Stefan; Schlereth, James; Schmidt, Evelyn; Schmidt, Michael; Schmieden, Kristof; Schmitt, Christian; Schmitt, Sebastian; Schmitz, Martin; Schöning, André; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schram, Malachi; Schroeder, Christian; Schroer, Nicolai; Schuh, Silvia; Schuler, Georges; Schultes, Joachim; Schultz-Coulon, Hans-Christian; Schulz, Holger; Schumacher, Jan; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwemling, Philippe; Schwienhorst, Reinhard; Schwierz, Rainer; Schwindling, Jerome; Scott, Bill; Searcy, Jacob; Sedykh, Evgeny; Segura, Ester; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Seliverstov, Dmitry; Sellden, Bjoern; Sellers, Graham; Seman, Michal; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Seuster, Rolf; Severini, Horst; Sevior, Martin; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shank, James; Shao, Qi Tao; Shapiro, Marjorie; Shatalov, Pavel; Shaver, Leif; Shaw, Christian; Shaw, Kate; Sherman, Daniel; Sherwood, Peter; Shibata, Akira; Shichi, Hideharu; Shimizu, Shima; Shimojima, Makoto; Shin, Taeksu; Shmeleva, Alevtina; Shochet, Mel; Short, Daniel; Shupe, Michael; Sicho, Petr; Sidoti, Antonio; Siebel, Anca-Mirela; Siegert, Frank; Siegrist, James; Sijacki, Djordje; Silbert, Ohad; Silva, José; Silver, Yiftah; Silverstein, Daniel; Silverstein, Samuel; Simak, Vladislav; Simard, Olivier; Simic, Ljiljana; Simion, Stefan; Simmons, Brinick; Simonyan, Margar; Sinervo, Pekka; Sinev, Nikolai; Sipica, Valentin; Siragusa, Giovanni; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skinnari, Louise Anastasia; Skovpen, Kirill; Skubic, Patrick; Skvorodnev, Nikolai; Slater, Mark; Slavicek, Tomas; Sliwa, Krzysztof; Sloan, Terrence; Sloper, John erik; Smakhtin, Vladimir; Smirnov, Sergei; Smirnova, Lidia; Smirnova, Oxana; Smith, Ben Campbell; Smith, Douglas; Smith, Kenway; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snow, Steve; Snow, Joel; Snuverink, Jochem; Snyder, Scott; Soares, Mara; Sobie, Randall; Sodomka, Jaromir; Soffer, Abner; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Soldatov, Evgeny; Soldevila, Urmila; Solfaroli Camillocci, Elena; Solodkov, Alexander; Solovyanov, Oleg; Sondericker, John; Soni, Nitesh; Sopko, Vit; Sopko, Bruno; Sorbi, Massimo; Sosebee, Mark; Soukharev, Andrey; Spagnolo, Stefania; Spanò, Francesco; Spighi, Roberto; Spigo, Giancarlo; Spila, Federico; Spiriti, Eleuterio; Spiwoks, Ralf; Spousta, Martin; Spreitzer, Teresa; Spurlock, Barry; St Denis, Richard Dante; Stahl, Thorsten; Stahlman, Jonathan; Stamen, Rainer; Stanecka, Ewa; Stanek, Robert; Stanescu, Cristian; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Staude, Arnold; Stavina, Pavel; Stavropoulos, Georgios; Steele, Genevieve; Steinbach, Peter; Steinberg, Peter; Stekl, Ivan; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stevenson, Kyle; Stewart, Graeme; Stillings, Jan Andre; Stockmanns, Tobias; Stockton, Mark; Stoerig, Kathrin; Stoicea, Gabriel; Stonjek, Stefan; Strachota, Pavel; Stradling, Alden; Straessner, Arno; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strang, Michael; Strauss, Emanuel; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Strong, John; Stroynowski, Ryszard; Strube, Jan; Stugu, Bjarne; Stumer, Iuliu; Stupak, John; Sturm, Philipp; Soh, Dart-yin; Su, Dong; Subramania, Halasya Siva; Succurro, Antonella; Sugaya, Yorihito; Sugimoto, Takuya; Suhr, Chad; Suita, Koichi; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Sushkov, Serge; Susinno, Giancarlo; Sutton, Mark; Suzuki, Yu; Svatos, Michal; Sviridov, Yuri; Swedish, Stephen; Sykora, Ivan; Sykora, Tomas; Szeless, Balazs; Sánchez, Javier; Ta, Duc; Tackmann, Kerstin; Taffard, Anyes; Tafirout, Reda; Taga, Adrian; Taiblum, Nimrod; Takahashi, Yuta; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Talby, Mossadek; Talyshev, Alexey; Tamsett, Matthew; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tanaka, Yoshito; Tani, Kazutoshi; Tannoury, Nancy; Tappern, Geoffrey; Tapprogge, Stefan; Tardif, Dominique; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tassi, Enrico; Tatarkhanov, Mous; Tayalati, Yahya; Taylor, Christopher; Taylor, Frank; Taylor, Geoffrey; Taylor, Wendy; Teixeira Dias Castanheira, Matilde; Teixeira-Dias, Pedro; Temming, Kim Katrin; Ten Kate, Herman; Teng, Ping-Kun; Terada, Susumu; Terashi, Koji; Terron, Juan; Terwort, Mark; Testa, Marianna; Teuscher, Richard; Thadome, Jocelyn; Therhaag, Jan; Theveneaux-Pelzer, Timothée; Thioye, Moustapha; Thoma, Sascha; Thomas, Juergen; Thompson, Emily; Thompson, Paul; Thompson, Peter; Thompson, Stan; Thomson, Evelyn; Thomson, Mark; Thun, Rudolf; Tic, Tomáš; Tikhomirov, Vladimir; Tikhonov, Yury; Timmermans, Charles; Tipton, Paul; Tique Aires Viegas, Florbela De Jes; Tisserant, Sylvain; Tobias, Jürgen; Toczek, Barbara; Todorov, Theodore; Todorova-Nova, Sharka; Toggerson, Brokk; Tojo, Junji; Tokár, Stanislav; Tokunaga, Kaoru; Tokushuku, Katsuo; Tollefson, Kirsten; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Tong, Guoliang; Tonoyan, Arshak; Topfel, Cyril; Topilin, Nikolai; Torchiani, Ingo; Torrence, Eric; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Traynor, Daniel; Trefzger, Thomas; Treis, Johannes; Tremblet, Louis; Tricoli, Alesandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Trinh, Thi Nguyet; Tripiana, Martin; Trischuk, William; Trivedi, Arjun; Trocmé, Benjamin; Troncon, Clara; Trottier-McDonald, Michel; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiakiris, Menelaos; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsung, Jieh-Wen; Tsuno, Soshi; Tsybychev, Dmitri; Tua, Alan; Tuggle, Joseph; Turala, Michal; Turecek, Daniel; Turk Cakir, Ilkay; Turlay, Emmanuel; Turra, Ruggero; Tuts, Michael; Tykhonov, Andrii; Tylmad, Maja; Tyndel, Mike; Tyrvainen, Harri; Tzanakos, George; Uchida, Kirika; Ueda, Ikuo; Ueno, Ryuichi; Ugland, Maren; Uhlenbrock, Mathias; Uhrmacher, Michael; Ukegawa, Fumihiko; Unal, Guillaume; Underwood, David; Undrus, Alexander; Unel, Gokhan; Unno, Yoshinobu; Urbaniec, Dustin; Urkovsky, Evgeny; Urrejola, Pedro; Usai, Giulio; Uslenghi, Massimiliano; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Vahsen, Sven; Valenta, Jan; Valente, Paolo; Valentinetti, Sara; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; van der Graaf, Harry; van der Kraaij, Erik; Van Der Leeuw, Robin; van der Poel, Egge; van der Ster, Daniel; Van Eijk, Bob; van Eldik, Niels; van Gemmeren, Peter; van Kesteren, Zdenko; van Vulpen, Ivo; Vandelli, Wainer; Vandoni, Giovanna; Vaniachine, Alexandre; Vankov, Peter; Vannucci, Francois; Varela Rodriguez, Fernando; Vari, Riccardo; Varnes, Erich; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vassilakopoulos, Vassilios; Vazeille, Francois; Vegni, Guido; Veillet, Jean-Jacques; Vellidis, Constantine; Veloso, Filipe; Veness, Raymond; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vest, Anja; Vetterli, Michel; Vichou, Irene; Vickey, Trevor; Viehhauser, Georg; Viel, Simon; Villa, Mauro; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinek, Elisabeth; Vinogradov, Vladimir; Virchaux, Marc; Viret, Sébastien; Virzi, Joseph; Vitale, Antonio; Vitells, Ofer; Viti, Michele; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vlasak, Michal; Vlasov, Nikolai; Vogel, Adrian; Vokac, Petr; Volpi, Guido; Volpi, Matteo; Volpini, Giovanni; von der Schmitt, Hans; von Loeben, Joerg; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorobiev, Alexander; Vorwerk, Volker; Vos, Marcel; Voss, Rudiger; Voss, Thorsten Tobias; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vu Anh, Tuan; Vuillermet, Raphael; Vukotic, Ilija; Wagner, Wolfgang; Wagner, Peter; Wahlen, Helmut; Wakabayashi, Jun; Walbersloh, Jorg; Walch, Shannon; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wall, Richard; Waller, Peter; Wang, Chiho; Wang, Haichen; Wang, Hulin; Wang, Jike; Wang, Jin; Wang, Joshua C; Wang, Rui; Wang, Song-Ming; Warburton, Andreas; Ward, Patricia; Warsinsky, Markus; Watkins, Peter; Watson, Alan; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Anthony; Waugh, Ben; Weber, Jens; Weber, Marc; Weber, Michele; Weber, Pavel; Weidberg, Anthony; Weigell, Philipp; Weingarten, Jens; Weiser, Christian; Wellenstein, Hermann; Wells, Phillippa; Wen, Mei; Wenaus, Torre; Wendler, Shanti; Weng, Zhili; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Werth, Michael; Wessels, Martin; Weydert, Carole; Whalen, Kathleen; Wheeler-Ellis, Sarah Jane; Whitaker, Scott; White, Andrew; White, Martin; White, Sebastian; Whitehead, Samuel Robert; Whiteson, Daniel; Whittington, Denver; Wicek, Francois; Wicke, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik, Liv Antje Mari; Wijeratne, Peter Alexander; Wildauer, Andreas; Wildt, Martin Andre; Wilhelm, Ivan; Wilkens, Henric George; Will, Jonas Zacharias; Williams, Eric; Williams, Hugh; Willis, William; Willocq, Stephane; Wilson, John; Wilson, Michael Galante; Wilson, Alan; Wingerter-Seez, Isabelle; Winkelmann, Stefan; Winklmeier, Frank; Wittgen, Matthias; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wooden, Gemma; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wraight, Kenneth; Wright, Catherine; Wrona, Bozydar; Wu, Sau Lan; Wu, Xin; Wu, Yusheng; Wulf, Evan; Wunstorf, Renate; Wynne, Benjamin; Xaplanteris, Leonidas; Xella, Stefania; Xie, Song; Xie, Yigang; Xu, Chao; Xu, Da; Xu, Guofa; Yabsley, Bruce; Yamada, Miho; Yamamoto, Akira; Yamamoto, Kyoko; Yamamoto, Shimpei; Yamamura, Taiki; Yamaoka, Jared; Yamazaki, Takayuki; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Un-Ki; Yang, Yi; Yang, Yi; Yang, Zhaoyu; Yanush, Serguei; Yao, Weiming; Yao, Yushu; Yasu, Yoshiji; Ybeles Smit, Gabriel Valentijn; Ye, Jingbo; Ye, Shuwei; Yilmaz, Metin; Yoosoofmiya, Reza; Yorita, Kohei; Yoshida, Riktura; Young, Charles; Youssef, Saul; Yu, Dantong; Yu, Jaehoon; Yu, Jie; Yuan, Li; Yurkewicz, Adam; Zaets, Vassilli; Zaidan, Remi; Zaitsev, Alexander; Zajacova, Zuzana; Zalite, Youris; Zanello, Lucia; Zarzhitsky, Pavel; Zaytsev, Alexander; Zeitnitz, Christian; Zeller, Michael; Zemla, Andrzej; Zendler, Carolin; Zenin, Anton; Zenin, Oleg; Ženiš, Tibor; Zenonos, Zenonas; Zenz, Seth; Zerwas, Dirk; Zevi della Porta, Giovanni; Zhan, Zhichao; Zhang, Dongliang; Zhang, Huaqiao; Zhang, Jinlong; Zhang, Xueyao; Zhang, Zhiqing; Zhao, Long; Zhao, Tianchi; Zhao, Zhengguo; Zhemchugov, Alexey; Zheng, Shuchen; Zhong, Jiahang; Zhou, Bing; Zhou, Ning; Zhou, Yue; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Yingchun; Zhuang, Xuai; Zhuravlov, Vadym; Zieminska, Daria; Zimmermann, Robert; Zimmermann, Simone; Zimmermann, Stephanie; Ziolkowski, Michael; Zitoun, Robert; Živković, Lidija; Zmouchko, Viatcheslav; Zobernig, Georg; Zoccoli, Antonio; Zolnierowski, Yves; Zsenei, Andras; zur Nedden, Martin; Zutshi, Vishnu; Zwalinski, Lukasz

    2012-01-03

    Proton-proton collisions at $\\sqrt{s}=7$ TeV and heavy ion collisions at $\\sqrt{s_{NN}}$=2.76 TeV were produced by the LHC and recorded using the ATLAS experiment's trigger system in 2010. The LHC is designed with a maximum bunch crossing rate of 40 MHz and the ATLAS trigger system is designed to record approximately 200 of these per second. The trigger system selects events by rapidly identifying signatures of muon, electron, photon, tau lepton, jet, and B meson candidates, as well as using global event signatures, such as missing transverse energy. An overview of the ATLAS trigger system, the evolution of the system during 2010 and the performance of the trigger system components and selections based on the 2010 collision data are shown. A brief outline of plans for the trigger system in 2011 is presented

  20. Networked event-triggered control: an introduction and research trends

    Science.gov (United States)

    Mahmoud, Magdi S.; Sabih, Muhammad

    2014-11-01

    A physical system can be studied as either continuous time or discrete-time system depending upon the control objectives. Discrete-time control systems can be further classified into two categories based on the sampling: (1) time-triggered control systems and (2) event-triggered control systems. Time-triggered systems sample states and calculate controls at every sampling instant in a periodic fashion, even in cases when states and calculated control do not change much. This indicates unnecessary and useless data transmission and computation efforts of a time-triggered system, thus inefficiency. For networked systems, the transmission of measurement and control signals, thus, cause unnecessary network traffic. Event-triggered systems, on the other hand, have potential to reduce the communication burden in addition to reducing the computation of control signals. This paper provides an up-to-date survey on the event-triggered methods for control systems and highlights the potential research directions.