WorldWideScience

Sample records for upper gastrointestinal x-ray

  1. The study on clinical conditions and skin dose of upper-gastrointestinal x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Kim, Sung Chul; Ahn, Sung Min; Jang, Sang Sup

    2007-01-01

    This study examined present conditions of upper-gastrointestinal X-ray fluoroscopy and patient skin dose. The authors elected 21 equipment to check the X-ray equipment and exposure factor of fluoroscopy and spot exposure in university hospitals, hospitals, and clinics where perform upper-gastrointestinal X-ray fluoroscopy more than five times every day in Incheon areas. The amount of patient's skin dose during upper-gastrointestinal X-ray fluoroscopy was measured by ionization chamber

  2. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Femur (Upper Leg) KidsHealth / For Parents / X- ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  3. Comparative analysis of upper gastrointestinal endoscopy, double-contrast upper gastrointestinal barium X-ray radiography, and the titer of serum anti-Helicobacter pylori IgG focusing on the diagnosis of atrophic gastritis.

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Takahashi, Yu; Minatsuki, Chihiro; Nakayama, Chiemi; Matsuda, Rie; Shimamoto, Takeshi; Takeuchi, Chihiro; Kodashima, Shinya; Ono, Satoshi; Tsuji, Yosuke; Fujishiro, Mitsuhiro; Wada, Ryoichi; Mitsushima, Toru; Koike, Kazuhiko

    2016-04-01

    Upper gastrointestinal endoscopy (UGI-ES) and double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) are two major image-based methods to diagnose atrophic gastritis, which is mostly induced by Helicobacter pylori infection. However, there have been few studies directly comparing them. Atrophic gastritis was evaluated using the data of 962 healthy subjects who underwent UGI-ES and UGI-XR within 1 year. Based on UGI-ES and UGI-XR, 602 subjects did not have atrophic gastritis and 254 subjects did have it. Considering UGI-ES-based atrophic gastritis as the standard, sensitivity and specificity of UGI-XR-based atrophic gastritis were 92.0 % (254/276) and 92.8 % (602/649), respectively. The seven-grade Kimura-Takemoto classification of UGI-ES-based atrophic gastritis showed a strong and significant association with the four-grade UGI-XR-based atrophic gastritis. Sensitivity and specificity of serum anti-Helicobacter pylori IgG to detect UGI-ES/UGI-XR-based atrophic gastritis were 89.4 % (227/254) and 99.8 % (601/602), indicating that atrophic gastritis can be overlooked according to serum anti-Helicobacter pylori IgG alone.

  4. Development of a method to calculate organ doses for the upper gastrointestinal fluoroscopic examination

    International Nuclear Information System (INIS)

    Suleiman, O.H.

    1989-01-01

    A method was developed to quantitatively measure the upper gastrointestinal fluoroscopic examination in order to calculate organ doses. The dynamic examination was approximated with a set of discrete x-ray fields. Once the examination was segmented into discrete x-ray fields appropriate organ dose tables were generated using an existing computer program for organ dose calculations. This, along with knowledge of the radiation exposures associated with each of the fields, enabled the calculation of organ doses for the entire dynamic examination. The protocol involves videotaping the examination while fluoroscopic technique factors, tube current and tube potential, are simultaneously recorded on the audio tracks of the videotape. Subsequent analysis allows the dynamic examination to be segmented into a series of discrete x-ray fields uniquely defined by field size, projection, and anatomical region. The anatomical regions associated with the upper gastrointestinal examination were observed to be the upper, middle, and lower esophagus, the gastroesophageal junction, the stomach, and the duodenum

  5. Some debatable problems of the X-ray diagnosis of gastrointestinal deseases

    International Nuclear Information System (INIS)

    Velichkov, L.; Pomakov, P.

    1989-01-01

    Analysis is made of the diagnostic algorithm in different gastrointestinal diseases and the place of x-ray diagnosis in it. According to the nosological items and symptoms the diseases may be divided in four groups wth the following rating: 1) the X-ray examination has very low diagnostic value and should be replaced by other image providing methods; 2) the X-ray examination is a supplementary method of help in some individual cases; 3) X-ray examination has a definite place in the diagnostic algorhythm and is applied for verification together with other methods of examination; 4) the X-ray examination is leading method of choice for establishing the ultimate image diagnosis. It is concluded that the application of X-ray diagnostics as a whole should be restricted when it is ineffective and helpless. 21 refs

  6. Nonvariceal upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang; Golzarian, Jafar

    2007-01-01

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  7. Nonvariceal upper gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang [University of Iowa, Department of Radiology, Iowa, IA (United States); Golzarian, Jafar [University of Iowa, Department of Radiology, Iowa, IA (United States); University of Iowa, Department of Radiology, Carver College of Medicine, Iowa, IA (United States)

    2007-07-15

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  8. Barium appendicitis after upper gastrointestinal imaging.

    Science.gov (United States)

    Novotny, Nathan M; Lillemoe, Keith D; Falimirski, Mark E

    2010-02-01

    Barium appendicitis (BA) is a rarely seen entity with fewer than 30 reports in the literature. However, it is a known complication of barium imaging. To report a case of BA in a patient whose computed tomography (CT) scan was initially read as foreign body ingestion. An 18-year-old man presented with right lower quadrant pain after upper gastrointestinal imaging 2 weeks prior. A CT scan was obtained of his abdomen and pelvis that revealed a finding that was interpreted as a foreign body at the area of the terminal ileum. A plain X-ray study of the abdomen revealed radiopaque appendicoliths. Pathology confirmed the diagnosis of barium appendicitis. BA is a rare entity and the pathogenesis is unclear. Shorter intervals between barium study and presentation with appendicitis usually correlate with fewer complications. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  9. Upper gastrointestinal bleeding in patients with CKD.

    Science.gov (United States)

    Liang, Chih-Chia; Wang, Su-Ming; Kuo, Huey-Liang; Chang, Chiz-Tzung; Liu, Jiung-Hsiun; Lin, Hsin-Hung; Wang, I-Kuan; Yang, Ya-Fei; Lu, Yueh-Ju; Chou, Che-Yi; Huang, Chiu-Ching

    2014-08-07

    Patients with CKD receiving maintenance dialysis are at risk for upper gastrointestinal bleeding. However, the risk of upper gastrointestinal bleeding in patients with early CKD who are not receiving dialysis is unknown. The hypothesis was that their risk of upper gastrointestinal bleeding is negatively linked to renal function. To test this hypothesis, the association between eGFR and risk of upper gastrointestinal bleeding in patients with stages 3-5 CKD who were not receiving dialysis was analyzed. Patients with stages 3-5 CKD in the CKD program from 2003 to 2009 were enrolled and prospectively followed until December of 2012 to monitor the development of upper gastrointestinal bleeding. The risk of upper gastrointestinal bleeding was analyzed using competing-risks regression with time-varying covariates. In total, 2968 patients with stages 3-5 CKD who were not receiving dialysis were followed for a median of 1.9 years. The incidence of upper gastrointestinal bleeding per 100 patient-years was 3.7 (95% confidence interval, 3.5 to 3.9) in patients with stage 3 CKD, 5.0 (95% confidence interval, 4.8 to 5.3) in patients with stage 4 CKD, and 13.9 (95% confidence interval, 13.1 to 14.8) in patients with stage 5 CKD. Higher eGFR was associated with a lower risk of upper gastrointestinal bleeding (P=0.03), with a subdistribution hazard ratio of 0.93 (95% confidence interval, 0.87 to 0.99) for every 5 ml/min per 1.73 m(2) higher eGFR. A history of upper gastrointestinal bleeding (Pupper gastrointestinal bleeding risk. In patients with CKD who are not receiving dialysis, lower renal function is associated with higher risk for upper gastrointestinal bleeding. The risk is higher in patients with previous upper gastrointestinal bleeding history and low serum albumin. Copyright © 2014 by the American Society of Nephrology.

  10. Profiling lifetime episodes of upper gastrointestinal bleeding among ...

    African Journals Online (AJOL)

    Profiling lifetime episodes of upper gastrointestinal bleeding among patients from rural Sub-Saharan Africa where schistosoma mansoni is endemic. ... female sex, history of blood transfusion, abdominal collaterals, esophageal varices, pattern x periportal fibrosis, anemia, and thrombocytopenia) significantly associated ...

  11. Multiple primary malignant tumors of upper gastrointestinal tract:A novel role of ~(18)F-FDG PET/CT

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM: To evaluate the capacity of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for detecting multiple primary cancer of upper gastrointestinal (UGI) tract. METHODS: Fifteen patients (12 without cancer histories and 3 with histories of upper GI tract cancer) were investigated due to the suspicion of primary cancer of UGI tract on X-ray barium meal and CT scan. Subsequent whole body 18F-FDG PET/CT scan was carried out for initial staging or restaging. All the patient...

  12. Examination of the gastrointestinal tract using the tussian X-ray contrast substance BAR-VIPS based on barium sulfate

    International Nuclear Information System (INIS)

    Ratobyl'skij, G.V.; Kaluzhskij, A.A.

    1997-01-01

    Results of X-ray studies of gastrointestinal tract using domestic X-ray contrast preparation based on barium sulfate BAR-VIPS developed by VIPS-MED company (t. Fryazino, Moscow region). Testing of the preparation has shown that BAR-VIPS permits to diagnose every pathological changes in esophagus, stomach, rectum, small intestine as well as to diagnose successfully large intestine diseases

  13. The upper limits of the SNR in radiography and CT with polyenergetic x-rays

    International Nuclear Information System (INIS)

    Shikhaliev, Polad M

    2010-01-01

    The aim of the study is to determine the upper limits of the signal-to-noise ratio (SNR) in radiography and computed tomography (CT) with polyenergetic x-ray sources. In x-ray imaging, monoenergetic x-rays provide a higher SNR compared to polyenergetic x-rays. However, the SNR in polyenergetic x-ray imaging can be increased when a photon-counting detector is used and x-rays are optimally weighted according to their energies. For a particular contrast/background combination and at a fixed x-ray entrance skin exposure, the SNR in energy-weighting x-ray imaging depends on tube voltage and can be maximized by selecting the optimal tube voltage. The SNR in energy-weighted x-ray images acquired at this optimal tube voltage is the highest SNR that can be achieved with polyenergetic x-ray sources. The optimal tube voltages and the highest SNR were calculated and compared to the SNR of monoenergetic x-ray imaging. Monoenergetic, energy-weighting polyenergetic and energy-integrating polyenergetic x-ray imagings were simulated at a fixed entrance skin exposure of 20 mR. The tube voltages varied in the range of 30-140 kVp with 10 kV steps. Contrast elements of CaCO 3 , iodine, adipose and tumor with thicknesses of 280 mg cm -2 , 15 mg cm -2 , 1 g cm -2 and 1 g cm -2 , respectively, inserted in a soft tissue background with 10 cm and 20 cm thicknesses, were used. The energy weighting also improves the contrast-to-noise ratio (CNR) in CT when monoenergetic CT projections are optimally weighted prior to CT reconstruction (projection-based weighting). Alternatively, monoenergetic CT images are reconstructed, optimally weighted and composed to yield a final CT image (image-based weighting). Both projection-based and image-based weighting methods improve the CNR in CT. An analytical approach was used to determine which of these two weighting methods provides the upper limit of the CNR in CT. The energy-weighting method was generalized and expanded as a weighting method applicable in

  14. Cecal perforation with an ascending colon cancer caused by upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Hiroyuki Miyatani

    2009-04-01

    Full Text Available Hiroyuki Miyatani1, Yukio Yoshida1, Hirokazu Kiyozaki21Department of Gastroenterology, Jichi Medical University, Saitama Medical Center, Saitama, Japan; 2Department of Surgery, Jichi Medical University, Saitama Medical Center, Saitama, JapanAbstract: Colonic perforation caused by upper gastrointestinal (GI endoscopy is extremely rare. A 69-year-old woman was referred to our hospital because of abdominal fullness. Colonoscopy could be performed only up to the hepatic flexure due to an elongated colon and residual stools. Because her symptoms improved, upper GI endoscopy was performed 11 days later. The patient developed severe abdominal pain two hours after the examination. Abdominal X-ray and computed tomography showed massive free air. Immediate laparotomy was performed for the intestinal perforation. After removal of stool, a perforation site was detected in the cecum with an invasive ascending colon cancer. Therefore, a right hemicolectomy, ileostomy, and transverse colostomy were performed. Although she developed postoperative septicemia, the patient was discharged 38 days after admission. Seven months postoperatively, the patient died of lung, liver, and brain metastases. Even in cases with a lesion that is not completely obstructed, it is important to note that air insufflations during upper GI endoscopy can perforate the intestinal wall in patients with advanced colon cancer.Keywords: colonic perforation, colon cancer, upper gastrointestinal endoscopy, fecal peritonitis

  15. Corrosive injuries of the upper gastrointestinal tract

    Directory of Open Access Journals (Sweden)

    Babu Lal Meena

    2017-01-01

    Full Text Available Corrosive injury of the upper gastrointestinal tract is a worldwide clinical problem, mostly occurring in children. Alkaline agents produce deeper injuries whereas acidic agents produce superficial injuries usually. Hoarseness, stridor, and respiratory distress indicate airway injury. Dysphagia, odynophagia, and drooling of saliva suggest esophageal injury whereas abdominal pain, nausea, and vomiting are indicative of stomach injury. X-rays should be done to rule out perforation. Endoscopy is usually recommended in the first 12–48 h although it is safe up to 96 h after caustic ingestion. Endoscopy should be performed with caution and gentle insufflation. Initial management includes getting intravenous access and replacement of fluids. Hyperemia and superficial ulcerations have excellent recovery while deeper injuries require total parenteral nutrition or feeding jejunostomy. Patients suspected of perforation should be subjected to laparotomy. Common complications after corrosive injury are esophageal stricture, gastric outlet obstruction, and development of esophageal and gastric carcinoma.

  16. Gastric polyps diagnosed by double-contrast upper gastrointestinal barium X-ray radiography mostly arise from the Helicobacter pylori-negative stomach with low risk of gastric cancer in Japan.

    Science.gov (United States)

    Takeuchi, Chihiro; Yamamichi, Nobutake; Shimamoto, Takeshi; Takahashi, Yu; Mitsushima, Toru; Koike, Kazuhiko

    2017-03-01

    Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is a method broadly used for gastric cancer screening in Japan. Gastric polyp is one of the most frequent findings detected by UGI-XR, but how to handle it remains controversial. Gastric polyps of the 17,264 generally healthy subjects in Japan who underwent UGI-XR or upper gastrointestinal endoscopy (UGI-ES) in 2010 were analyzed. Of the 6,433 UGI-XR examinees (3,405 men and 3,028 women, 47.4 ± 9.0 years old), gastric polyps were detected in 464 men (13.6 %) and 733 women (24.2 %) and were predominantly developed on the non-atrophic gastric mucosa (p gastric polyps has significant association with lower value of serum anti-Helicobacter pylori IgG titer, female gender, lighter smoking habit, older age, and normal range of body mass index (≥18.5 and gastric cancer occurred in 7 subjects (0.11 %), but none of them had gastric polyps at the beginning of the follow-up period. Of the 2,722 subjects with gastric polyps among the 10,831 UGI-ES examinees in the same period, 2,446 (89.9 %) had fundic, 267 (9.8 %) had hyperplastic, and 9 (0.3 %) had adenomatous/cancerous polyps. Gastric polyps diagnosed by UGI-XR predominantly arise on the Helicobacter pylori-negative gastric mucosa with a low risk of gastric cancer in Japan. In the prospective observation, none of the UGI-XR examinees with gastric polyps developed gastric cancer for at least 3 years subsequently.

  17. Upper gastrointestinal bleeding.

    Science.gov (United States)

    Feinman, Marcie; Haut, Elliott R

    2014-02-01

    Upper gastrointestinal (GI) bleeding remains a commonly encountered diagnosis for acute care surgeons. Initial stabilization and resuscitation of patients is imperative. Stable patients can have initiation of medical therapy and localization of the bleeding, whereas persistently unstable patients require emergent endoscopic or operative intervention. Minimally invasive techniques have surpassed surgery as the treatment of choice for most upper GI bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Unsedated Flexible Upper Gastrointestinal Endoscopy: Need for ...

    African Journals Online (AJOL)

    Background: To determine the incidence of oxygen desaturation and whether routine oxygen monitoring is necessary during unsedated diagnostic flexible upper gastrointestinal endoscopy. Methods: A prospective study involving 54 consecutive in and out patients who had diagnostic upper gastrointestinal endoscopy at ...

  19. X-ray upper airway changes in individuals suffering from obstructive respiratory disorders during sleep

    International Nuclear Information System (INIS)

    Shakhov, A.A.; Rabukhina, N.A.; Nerobeev, A.I.; Vasil'ev, A.Yu.

    2000-01-01

    Obstructive respiratory disorders during sleep present an important medical and social problem. Serious dysfunctions of cardiovascular, nervous, endocrine and other vital systems of the body reduce longevity and life quality. On the other hand, load nocturnal snore and abnormal during sleepiness cause great damage to family life, reduce working capacity and induce accidents. X-ray visualization of the upper airways is essential in diagnosing obstructive upper airway states and selecting patients for surgical treatment. The paper presents the author's own experience in using various X-ray diagnostic methods in patients with chronic snore and obstructive sleep apnoea-hypopnoea syndrome [ru

  20. CALET UPPER LIMITS ON X-RAY AND GAMMA-RAY COUNTERPARTS OF GW151226

    Energy Technology Data Exchange (ETDEWEB)

    Adriani, O.; Bongi, M.; Castellini, G. [University of Florence, Via Sansone, 1, I-50019 Sesto, Fiorentino (Italy); Akaike, Y. [Universities Space Research Association, 7178 Columbia Gateway Drive, Columbia, MD 21046 (United States); Asano, K. [Institute for Cosmic Ray Research, The University of Tokyo, 5-1-5 Kashiwa-no-Ha, Kashiwa, Chiba 277-8582 (Japan); Asaoka, Y. [JEM Mission Operations and Integration Center, Human Spaceflight Technology Directorate, Japan Aerospace Exploration Agency, 2-1-1 Sengen, Tsukuba, Ibaraki 305-8505 (Japan); Bagliesi, M. G.; Bigongiari, G.; Bonechi, S.; Brogi, P.; Felice, V. Di [National Institute for Nuclear Physics (INFN), Piazza dei Caprettari, 70, I-00186 Rome (Italy); Binns, W. R.; Buckley, J. H. [Department of Physics, Washington University, One Brookings Drive, St. Louis, MO 63130-4899 (United States); Cannady, N.; Cherry, M. L.; Guzik, T. G. [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA 70803 (United States); Checchia, C.; Collazuol, G. [Department of Physics and Astronomy, University of Padova, Via Marzolo, 8, I-35131 Padova (Italy); Ebisawa, K.; Fuke, H., E-mail: nakahira@crab.riken.jp, E-mail: yoichi.asaoka@aoni.waseda.jp, E-mail: tsakamoto@phys.aoyama.ac.jp [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, 3-1-1 Yoshinodai, Chuo, Sagamihara, Kanagawa 252-5210 (Japan); and others

    2016-09-20

    We present upper limits in the hard X-ray and gamma-ray bands at the time of the Laser Interferometer Gravitational-wave Observatory (LIGO) gravitational-wave event GW151226 derived from the CALorimetric Electron Telescope ( CALET ) observation. The main instrument of CALET , CALorimeter (CAL), observes gamma-rays from ∼1 GeV up to 10 TeV with a field of view of ∼2 sr. The CALET gamma-ray burst monitor (CGBM) views ∼3 sr and ∼2 π sr of the sky in the 7 keV–1 MeV and the 40 keV–20 MeV bands, respectively, by using two different scintillator-based instruments. The CGBM covered 32.5% and 49.1% of the GW151226 sky localization probability in the 7 keV–1 MeV and 40 keV–20 MeV bands respectively. We place a 90% upper limit of 2 × 10{sup −7} erg cm{sup −2} s{sup −1} in the 1–100 GeV band where CAL reaches 15% of the integrated LIGO probability (∼1.1 sr). The CGBM 7 σ upper limits are 1.0 × 10{sup −6} erg cm{sup −2} s{sup −1} (7–500 keV) and 1.8 × 10{sup −6} erg cm{sup −2} s{sup −1} (50–1000 keV) for a 1 s exposure. Those upper limits correspond to the luminosity of 3–5 × 10{sup 49} erg s{sup −1}, which is significantly lower than typical short GRBs.

  1. A STUDY ON UPPER GASTROINTESTINAL ENDOSCOPIC FINDINGS IN PATIENTS WITH UPPER GASTROINTESTINAL BLEEDING

    Directory of Open Access Journals (Sweden)

    Salla Surya Prakasa Rao

    2016-10-01

    Full Text Available BACKGROUND Vomiting of blood almost always proximal to the ligament of Treitz is the upper gastrointestinal haemorrhage. The incidence of acute upper gastrointestinal haemorrhage has been estimated to be 50-100 per 1,00,000 person per year, with an annual hospitalization rate of approximately 100 per 1, 00,000 hospital admission. This study is to find out the prevalence of nature of lesion on Upper Gastrointestinal Endoscopy in patients admitted for Gastrointestinal bleeding. (UGI Bleed. MATERIALS AND METHODS Place of Study- Department of General Medicine, Andhra Medical College, Visakhapatnam, India. Type of Study- Prospective study. Period of Study- July 2015 to August 2016. RESULTS The Results Study on Endoscopic Findings in Upper Gastro Intestinal Bleed are 1. The peptic ulcer disease was the most common lesion found on endoscopy with prevalence of 54%. 2. Varices contributes second common lesion, next to peptic ulcer disease in UGI bleed with prevalence of 16%. 3. Minor UGI bleed was the commonest presentation. Majority of lesions (60% presented with minor UGI bleed, 28% lesions presented as moderate UGI bleed. Only 8% presented as major UGI bleed. 4. Varices account for the most common cause for major UGI bleed contributing 50%. 5. Gastric ulcer was commonest lesions accounting for 37 cases (37% among 72 cases having single acid peptic lesions on endoscopy. The second most common is duodenal ulcer (31%. 6. Multiple lesions were found in 10% of cases. Peptic ulcer lesions were found in 20% of total number of varices cases. CONCLUSION Peptic ulcer disease was found to be most common lesion causing UGI bleed, with most common presentation as minor UGI bleed and variceal bleed being most common cause of major UGI bleed.

  2. X-ray filter for chest X-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    A description is given of an X-ray filter comprised of a sheet of radiation absorbing material with an opening corresponding to the spine and central portion of the heart. The upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter. This filter will permit an acceptable density level of x-ray exposure for the lungs while allowing a higher level of x-ray exposure for the mediastinum areas of the body. (author)

  3. Upper gastrointestinal bleeding - state of the art.

    Science.gov (United States)

    Szura, Mirosław; Pasternak, Artur

    2014-01-01

    Upper gastrointestinal (GI) bleeding is a condition requiring immediate medical intervention, with high associated mortality exceeding 10%. The most common cause of upper GI bleeding is peptic ulcer disease, which largely corresponds to the intake of NSAIDs and Helicobacter pylori infection. Endoscopy is the essential tool for the diagnosis and treatment of active upper GI hemorrhage. Endoscopic therapy together with proton pump inhibitors and eradication of Helicobacter pylori significantly reduces rebleeding rates, mortality and number of emergency surgical interventions. This paper presents contemporary data on the diagnosis and treatment of upper gastrointestinal bleeding.

  4. X-ray filter for chest x-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    Filter for use in medical x-ray apparatus to permit higher intensity x-ray exposure in the heart and mediastinum area while maintaining a normal level of x-ray exposure in other areas of the body, particlarly in the lung area. The filter comprises a sheet of radiation absorbing material having an opening therein, said opening corresponding to the spine and central portion of the heart. Accordingly, the upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter

  5. Transfusion strategy for acute upper gastrointestinal bleeding.

    Science.gov (United States)

    Handel, James; Lang, Eddy

    2015-09-01

    Clinical question Does a hemoglobin transfusion threshold of 70 g/L yield better patient outcomes than a threshold of 90 g/L in patients with acute upper gastrointestinal bleeding? Article chosen Villanueva C, Colomo A, Bosch A, et al. Transfusion strategies for acute upper gastrointestinal bleeding. N Engl J Med 2013;368(1):11-21. Study objectives The authors of this study measured mortality, from any cause, within the first 45 days, in patients with acute upper gastrointestinal bleeding, who were managed with a hemoglobin threshold for red cell transfusion of either 70 g/L or 90 g/L. The secondary outcome measures included rate of further bleeding and rate of adverse events.

  6. Percutaneous transsplenic varices embolization for upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Zhang Qiang; Li Jingyu; Lu Junliang; Xu Liyang; Liu Tao

    2010-01-01

    Objective: To investigate the value of percutaneous transsplenic varices embolization (PTSVE) for treatment of upper gastrointestinal bleeding. Methods: Twenty cases with liver cirrhosis and portal hypertension suffered upper gastrointestinal bleeding. PTSVE was administered to them with hardener and coils. Among them, 8 cases had massive hepatocellular carcinoma (HCC) in right lobe; 10 cases with hepatocellular carcinoma had portal vein tumor thrombus and occlusion; the other two cases with liver cirrhosis had portal vein thrombosis. All of these cases were not suitable for percutaneous transhepatic varices embolization (PTHVE). PTSVE was performed under the guidance of fluoroscopy. Results: Technical success was achieved in 18 patients. A total of 35 gastric coronary veins were embolized. In all these cases, upper gastrointestinal bleeding stopped after PTSVE. There was no recurrence within 1 month follow-up. No serious complication occurred. Conclusion: PTSVE is a safe and efficient alternative treatment for upper gastrointestinal bleeding, especially for cases with portal vein occlusion or with massive HCC in right lobe of liver. (authors)

  7. Method of X-ray examination of upper respiratory tracts

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Surenchik, V.I.; Shuster, M.A.; Sal'nikova, Eh.A.

    1982-01-01

    Method of X-ray examination of upper respiratory tracts by radiography both in direct and lateral projection with an introduction of radiocontrast media through tracheostoma is described. The main objective of the invention is to improve accuracy of diagnostics of larynx and trachea cicatrix structures in children. The objective is attained by the examination under general anesthesia; barium sulfate is simultaneously introduced through laryngoscope and tracheostoma, and polypositional radiography is accomplished just in the moment of air introduction under 130-170 mm Hg pressure in the amounts of 60-200 ml

  8. Upper gastrointestinal bleeding caused by severe esophagitis: a unique clinical syndrome.

    Science.gov (United States)

    Guntipalli, Prathima; Chason, Rebecca; Elliott, Alan; Rockey, Don C

    2014-12-01

    We have recognized a unique clinical syndrome in patients with upper gastrointestinal bleeding who are found to have severe esophagitis. We aimed to more clearly describe the clinical entity of upper gastrointestinal bleeding in patients with severe esophagitis. We conducted a retrospective matched case-control study designed to investigate clinical features in patients with carefully defined upper gastrointestinal bleeding and severe esophagitis. Patient data were captured prospectively via a Gastrointestinal Bleeding Healthcare Registry, which collects data on all patients admitted with gastrointestinal bleeding. Patients with endoscopically documented esophagitis (cases) were matched with randomly selected controls that had upper gastrointestinal bleeding caused by other lesions. Epidemiologic features in patients with esophagitis were similar to those with other causes of upper gastrointestinal bleeding. However, hematemesis was more common in patients with esophagitis 86% (102/119) than in controls 55% (196/357) (p bleeding than those without cirrhosis. We have described a unique clinical syndrome in patients with upper gastrointestinal bleeding who have erosive esophagitis. This syndrome is manifest by typical clinical features and is associated with favorable outcomes.

  9. in upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Sinan Uzman

    2016-07-01

    Full Text Available Introduction : There is increasing interest in sedation for upper gastrointestinal endoscopy (UGE. Prospective randomized studies comparing sedation properties and complications of propofol and midazolam/meperidine in upper gastrointestinal endoscopy (UGE are few. Aim: To compare propofol and midazolam/meperidine sedation for UGE in terms of cardiopulmonary side effects, patient and endoscopist satisfaction and procedure-related times. Material and methods: This was a prospective, randomized, double-blind study of propofol versus midazolam and meperidine in 100 patients scheduled for diagnostic upper gastrointestinal endoscopy. The patients were divided into propofol and midazolam/meperidine groups. Randomization was generated by a computer. Cardiopulmonary side effects (hypotension, bradycardia, hypoxemia, procedure-related times (endoscopy time, awake time, time to hospital discharge, and patient and endoscopist satisfaction were compared between groups. Results: There was no significant difference between the groups with respect to the cost, endoscopy time, or demographic and clinical characteristics of the patients. Awake time and time to hospital discharge were significantly shorter in the propofol group (6.58 ±4.72 vs. 9.32 ±4.26 min, p = 0.030 and 27.60 ±7.88 vs. 32.00 ±10.54 min, p = 0.019. Hypotension incidence was significantly higher in the propofol group (12% vs. 0%, p = 0.027. The patient and endoscopist satisfaction was better with propofol. Conclusions : Propofol may be preferred to midazolam/meperidine sedation, with a shorter awake and hospital discharge time and better patient and endoscopist satisfaction. However, hypotension risk should be considered with propofol, and careful evaluation is needed, particularly in cardiopulmonary disorders.

  10. Diagnosis and Management of Upper Gastrointestinal Neuroendocrine Tumors

    Directory of Open Access Journals (Sweden)

    Jun Liong Chin

    2017-11-01

    Full Text Available Upper gastrointestinal neuroendocrine tumors (NETs are rare tumors which are increasingly recognised by practising endoscopists. After confirmation by endoscopic biopsies of these focal lesions, many questions may arise. As NETs are less frequently encountered compared to other malignancies or gastrointestinal pathology, many endoscopists may not fully understand the natural history, diagnosis and management of these tumors. In this review, we aim to update the practising endoscopist on the key clinical features and management of patients with upper gastrointestinal NET.

  11. [Massive hemorrhage of upper gastrointestinal tract caused by gastrointestinal stromal tumor of the stomach--case report].

    Science.gov (United States)

    Lalović, Nenad; Dukić Vladicić, Nikolina; Marić, Radmil; Cuk, Mirjana; Simatović, Milan; Jokanović, Dragana

    2012-01-01

    Acute bleeding from the upper gastrointestinal system is a medical emergency which is followed by high mortality rate, ranging from 6 to 15% in spite of modern diagnostic methods and treatment. Bleeding from the upper gastrointestinal system may be caused by gastrointestinal stromal tumors of the stomach, which are mainly characterized by occult bleeding, while profuse bleeding rarely occurs accompanied by hemorrhagic shock. Gastrointestinal stromal tumors of stomach are the most common mesenchimal tumors of the gastrointestinal tract. In our study we showed a 60-year-old female patient with profuse bleeding from the stomach and the clinical picture of severe hemorrhagic shock, caused by gastrointestinal stromal tumor. An ovoid junction, raised towards the lumen, covered with ulcerated mucosa in several places and followed by massive arterial bleeding was found intraoperatively, after the performed gastrotomy. Histopathological examination with immunohistochemical analysis confirmed that this was a gastrointestinal stromal tumor of the stomach. Acute bleeding from the digestive system is a sudden and serious condition of the body. Urgent esophagogastroduodenoscopy is a sensitive and specific diagnostic and therapeutic method of choice. Massive bleeding from the upper gastrointestinal tract is very rarely caused by gastrointestinal stromal tumors, whose clinical picture is very heterogeneous and depends on tumor size and location. Abundant bleeding from the tumor is an indication for urgent surgical intervention. According to the literature massive hemorrhage of the upper digestive system can rarely be caused by gastrointestinal stromal tumor of the stomach. It is shown that abundant hemorrhage of the upper digestive tract can be caused with gastric gastrointestinal stromal tumor. Surgical resection is the main form of treatment of gastrointestinal stromal tumors of the digestive system and bleeding from these tumors caused by failure of endoscopic hemostasis.

  12. Upper gastrointestinal tract bleeding in Ilorin, Nigeria - a report of 30 ...

    African Journals Online (AJOL)

    Upper gastrointestinal tract bleeding in Ilorin, Nigeria - a report of 30 cases. A.B Olokoba, L.B Olokoba, A.A.G Jimoh. Abstract. Background: Upper gastrointestinal tract bleeding refers to blood loss within the intraluminal gastrointestinal tract from any location between the upper oesophagus to the duodenum at the ligament ...

  13. Diagnosis and management of upper gastrointestinal bleeding in children.

    Science.gov (United States)

    Owensby, Susan; Taylor, Kellee; Wilkins, Thad

    2015-01-01

    Upper gastrointestinal bleeding is an uncommon but potentially serious, life-threatening condition in children. Rapid assessment, stabilization, and resuscitation should precede all diagnostic modalities in unstable children. The diagnostic approach includes history, examination, laboratory evaluation, endoscopic procedures, and imaging studies. The clinician needs to determine carefully whether any blood or possible blood reported by a child or adult represents true upper gastrointestinal bleeding because most children with true upper gastrointestinal bleeding require admission to a pediatric intensive care unit. After the diagnosis is established, the physician should start a proton pump inhibitor or histamine 2 receptor antagonist in children with upper gastrointestinal bleeding. Consideration should also be given to the initiation of vasoactive drugs in all children in whom variceal bleeding is suspected. An endoscopy should be performed once the child is hemodynamically stable. © Copyright 2015 by the American Board of Family Medicine.

  14. Atrophic gastritis and enlarged gastric folds diagnosed by double-contrast upper gastrointestinal barium X-ray radiography are useful to predict future gastric cancer development based on the 3-year prospective observation.

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Ichinose, Masao; Takahashi, Yu; Minatsuki, Chihiro; Matsuda, Rie; Nakayama, Chiemi; Shimamoto, Takeshi; Kodashima, Shinya; Ono, Satoshi; Tsuji, Yosuke; Niimi, Keiko; Sakaguchi, Yoshiki; Kataoka, Yosuke; Saito, Itaru; Asada-Hirayama, Itsuko; Takeuchi, Chihiro; Yakabi, Seiichi; Kaikimoto, Hikaru; Matsumoto, Yuta; Yamaguchi, Daisuke; Kageyama-Yahara, Natsuko; Fujishiro, Mitsuhiro; Wada, Ryoichi; Mitsushima, Toru; Koike, Kazuhiko

    2016-07-01

    Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is the standard gastric cancer screening method in Japan. Atrophic gastritis and enlarged gastric folds are considered the two major features of Helicobacter pylori-induced chronic gastritis, but the clinical meaning of evaluating them by UGI-XR has not been elucidated. We analyzed healthy UGI-XR examinees without a history of gastrectomy, previous Helicobacter pylori eradication and usage of gastric acid suppressants. Of the 6433 subjects, 1936 (30.1 %) had atrophic gastritis and 1253 (19.5 %) had enlarged gastric folds. During the 3-year prospective observational follow-up, gastric cancer developed in seven subjects, six of whom (85.7 %) had atrophic gastritis with H. pylori infection and five of whom (71.4 %) had enlarged gastric folds with H. pylori infection. The Kaplan-Meier method with log-rank testing revealed that both UGI-XR-based atrophic gastritis (p = 0.0011) and enlarged gastric folds (p = 0.0003) are significant predictors for future gastric cancer incidence.

  15. Upper gastrointestinal symptoms in autoimmune gastritis

    Science.gov (United States)

    Carabotti, Marilia; Lahner, Edith; Esposito, Gianluca; Sacchi, Maria Carlotta; Severi, Carola; Annibale, Bruno

    2017-01-01

    Abstract Autoimmune gastritis is often suspected for its hematologic findings, and rarely the diagnosis is made for the presence of gastrointestinal symptoms. Aims of this cross-sectional study were to assess in a large cohort of patients affected by autoimmune gastritis the occurrence and the pattern of gastrointestinal symptoms and to evaluate whether symptomatic patients are characterized by specific clinical features. Gastrointestinal symptoms of 379 consecutive autoimmune gastritis patients were systematically assessed and classified following Rome III Criteria. Association between symptoms and anemia pattern, positivity to gastric autoantibodies, Helicobacter pylori infection, and concomitant autoimmune disease were evaluated. In total, 70.2% of patients were female, median age 55 years (range 17–83). Pernicious anemia (53.6%), iron deficiency anemia (34.8%), gastric autoantibodies (68.8%), and autoimmune disorders (41.7%) were present. However, 56.7% of patients complained of gastrointestinal symptoms, 69.8% of them had exclusively upper symptoms, 15.8% only lower and 14.4% concomitant upper and lower symptoms. Dyspepsia, subtype postprandial distress syndrome was the most represented, being present in 60.2% of symptomatic patients. Univariate and multivariate analyses showed that age gastritis is associated in almost 60% of cases with gastrointestinal symptoms, in particular dyspepsia. Dyspepsia is strictly related to younger age, no smoking, and absence of anemia. PMID:28072728

  16. Seven cases of upper gastrointestinal bleeding after cold biopsy

    OpenAIRE

    Alneaimi, Khaled; Abdelmoula, Ali; Vincent, Magalie; Savale, Camille; Baye, Birane; Lesur, Gilles

    2016-01-01

    Background and study aims: Routine biopsy of the upper gastrointestinal tract is performed with increasing frequency. It is generally considered to be safe without significant complication. However, gastrointestinal bleeding as a result of cold biopsy is a known complication. We report seven cases of upper gastrointestinal bleeding after cold biopsy and discuss clinical data, risks factors, severity and management of this event. We suggest that physicians must be more cautious with this rare ...

  17. Upper gastrointestinal bleeding, aneurismatic dilatation of the thoracic aorta and filling defect on the esophagogram

    Energy Technology Data Exchange (ETDEWEB)

    Naschitz, J.E.; Bassan, H.; Lazarov, N.; Grishkan, A.

    1982-06-01

    A patient is described with an aneurysm of the thoracic aorta, which has ruptured into the esophagus. An esophageal X-ray contrast study has revealed a filling defect at the contact site of the esophagus and the aortic aneurysm. The filling defect was due to a clot protruding from the aorta into the esophagus. This unique case calls attention to a diagnostic triad: upper gastrointestinal bleeding, aneurysm of the thoracic aorta, and filling defect in the esophagus at its site of contact with the enlarged aorta. This triad suggested aortoesophageal fistula (AEF) in the patient and could help in the diagnosis of atypical cases of AEF, where thoracic aortography has not been performed initially.

  18. Upper gastrointestinal bleeding, aneurismatic dilatation of the thoracic aorta and filling defect on the esophagogram

    International Nuclear Information System (INIS)

    Naschitz, J.E.; Bassan, H.; Lazarov, N.; Grishkan, A.; Haifa Univ.; Haifa Univ.

    1982-01-01

    A patient is described with an aneurysm of the thoracic aorta, which has ruptured into the esophagus. An esophageal X-ray contrast study has revealed a filling defect at the contact site of the esophagus and the aortic aneurysm. The filling defect was due to a clot protruding from the aorta into the esophagus. This unique case calls attention to a diagnostic triad: upper gastrointestinal bleeding, aneurysm of the thoracic aorta, and filling defect in the esophagus at its site of contact with the enlarged aorta. This triad suggested aortoesophageal fistula (AEF) in the patient and could help in the diagnosis of atypical cases of AEF, where thoracic aortography has not been performed initially. (orig.) [de

  19. [Antithrombotic therapy and nonvariceal upper gastrointestinal bleeding].

    Science.gov (United States)

    Belanová, Veronika; Gřiva, Martin

    2015-12-01

    The incidence of acute upper gastrointestinal bleeding is about 85-108/100,000 inhabitants per year, nonvariceal bleeding accounts for 80-90%. Antiplatelet and anticoagulation treatment are the significant risk factors for upper gastrointestinal bleeding. To evaluate the occurrence of upper gastrointestinal bleeding in the general community of patients in a county hospital. And to compare the role played by antiplatelet and anticoagulation drugs and other risk medication. Retrospective analysis of patients over 18 years of age who underwent endoscopy for acute upper gastrointestinal bleeding or anaemia (haemoglobinupper gastrointestinal tract during a hospital stay in 2013 (from January to June). We included 111 patients of average age 69±15 years, men 60%. Nonvariceal bleeding accounted for 90% of the cases. None of the patients with variceal bleeding (10% of patients) took antiplatelet or anticoagulation therapy. There were 100 patients with nonvariceal bleeding of average age 70±15, 61% men. With the symptoms of acute bleeding (hematemesis, melena) presented in 73% of patients. The most frequent cause of bleeding was gastric and duodenal ulcer (54%). 32% of patients with nonvariceal bleeding had antiplatelets, 19% anticoagulants and 10% used nonsteroidal anti-inflammatory drugs, selective serotonin reuptake inhibitors or corticosteroids. 30-days mortality of patients with nonvariceal bleeding was 11%, annual mortality was 23%. There was no significant difference in mortality, blood transfusion requirements or surgical intervention between the patients with antithrombotic agents and without them. 25% of patients (8 patients) using acetylsalicylic acid did not fulfil the indication for this treatment. Among the patients examined by endoscopy for symptomatic nonvariceal bleeding and/or anaemia (haemoglobingastrointestinal bleeding. With regard to that, it is alarming, that there still exists a nonnegligible percentage of patients taking acetylsalicylic acid even

  20. Short-term use of serotonin reuptake inhibitors and risk of upper gastrointestinal bleeding.

    Science.gov (United States)

    Wang, Yen-Po; Chen, Yung-Tai; Tsai, Chia-Fen; Li, Szu-Yuan; Luo, Jiing-Chyuan; Wang, Shuu-Jiun; Tang, Chao-Hsiun; Liu, Chia-Jen; Lin, Han-Chieh; Lee, Fa-Yauh; Chang, Full-Young; Lu, Ching-Liang

    2014-01-01

    The association between selective serotonin receptor inhibitors (SSRIs) and risk of upper gastrointestinal bleeding remains controversial. Previous studies have generally evaluated the issue for approximately 3 months, even though the SSRI-mediated inhibition of platelet serotonin concentrations occurs within 7-14 days. The authors explored the risk of upper gastrointestinal bleeding after short-term SSRI exposure by a case-crossover design. The records of psychiatric inpatients with upper gastrointestinal bleeding were retrieved from the Taiwan National Health Insurance Database (1998-2009). Rates of antidepressant use were compared for case and control periods with time windows of 7, 14, and 28 days. The adjusted self-matched odds ratios from a conditional logistic regression model were used to determine the association between SSRI use and upper gastrointestinal bleeding. A total of 5,377 patients with upper gastrointestinal bleeding were enrolled. The adjusted odds ratio for the risk of upper gastrointestinal bleeding after SSRI exposure was 1.67 (95% CI=1.23-2.26) for the 7-day window, 1.84 (95% CI=1.42-2.40) for the 14-day window, and 1.67 (95% CI=1.34-2.08) for the 28-day window. SSRIs with high and intermediate, but not low, affinity for serotonin transporter were associated with upper gastrointestinal bleeding. An elevated risk of upper gastrointestinal bleeding after SSRI exposure was seen in male but not female patients. Short-term SSRI use (7-28 days) is significantly associated with upper gastrointestinal bleeding. Gender differences may exist in the relationship between SSRI use and upper gastrointestinal bleeding. Physicians should carefully monitor signs of upper gastrointestinal bleeding even after short-term exposure to SSRIs, as is done with nonsteroidal anti-inflammatory drugs and aspirin.

  1. Rare upper gastrointestinal hemorrhage of cetuximab

    OpenAIRE

    Duan, Shi-Jie; Gao, Zi-Ming; Wang, Peng-Liang; Gong, Bao-Cheng; Huang, Han-Wei; Luo, Lei; Wang, Xin; Xing, Ya-Nan; Xu, Hui-Mian; Liu, Fu-Nan

    2017-01-01

    Abstract Rationale: cetuximab, an epidermal growth factor receptor inhibitor, is a targeted therapeutic regimen of colorectal cancers. Several common adverse effects have been found, such as cutaneous or gastrointestinal toxicity. However, according to the articles had been published, upper gastrointestinal bleeding (UGIB) is considered to be rare and its mechanism remains unclear. Patient concerns: In this report, we presented a 42-year-old male patient with advanced recto-sigmoid cancer. Af...

  2. Approach to upper gastrointestinal bleeding

    African Journals Online (AJOL)

    Upper gastrointestinal haemorrhage has a variety of causes (Table 1) and is the commonest complication of peptic ulceration and portal hypertension. Peptic ulceration in the duo- denum or stomach and oesophageal varices are the conditions most often responsible for patients who have the potential to present.

  3. Performance of upper gastrointestinal bleeding risk assessment scores in variceal bleeding

    DEFF Research Database (Denmark)

    Ngu, JH; Laursen, Stig Borbjerg; Chin, YK

    2017-01-01

    Performance of upper gastrointestinal bleeding risk assessment scores in variceal bleeding: a prospective international multicenter study.......Performance of upper gastrointestinal bleeding risk assessment scores in variceal bleeding: a prospective international multicenter study....

  4. Cardioprotective aspirin users and their excess risk of upper gastrointestinal complications.

    Science.gov (United States)

    Hernández-Díaz, Sonia; García Rodríguez, Luis A

    2006-09-20

    To balance the cardiovascular benefits from low-dose aspirin against the gastrointestinal harm caused, studies have considered the coronary heart disease risk for each individual but not their gastrointestinal risk profile. We characterized the gastrointestinal risk profile of low-dose aspirin users in real clinical practice, and estimated the excess risk of upper gastrointestinal complications attributable to aspirin among patients with different gastrointestinal risk profiles. To characterize aspirin users in terms of major gastrointestinal risk factors (i.e., advanced age, male sex, prior ulcer history and use of non-steroidal anti-inflammatory drugs), we used The General Practice Research Database in the United Kingdom and the Base de Datos para la Investigación Farmacoepidemiológica en Atención Primaria in Spain. To estimate the baseline risk of upper gastrointestinal complications according to major gastrointestinal risk factors and the excess risk attributable to aspirin within levels of these factors, we used previously published meta-analyses on both absolute and relative risks of upper gastrointestinal complications. Over 60% of aspirin users are above 60 years of age, 4 to 6% have a recent history of peptic ulcers and over 13% use other non-steroidal anti-inflammatory drugs. The estimated average excess risk of upper gastrointestinal complications attributable to aspirin is around 5 extra cases per 1,000 aspirin users per year. However, the excess risk varies in parallel to the underlying gastrointestinal risk and might be above 10 extra cases per 1,000 person-years in over 10% of aspirin users. In addition to the cardiovascular risk, the underlying gastrointestinal risk factors have to be considered when balancing harms and benefits of aspirin use for an individual patient. The gastrointestinal harms may offset the cardiovascular benefits in certain groups of patients where the gastrointestinal risk is high and the cardiovascular risk is low.

  5. X-ray Bursts in Neutron Star and Black Hole Binaries from USA Data: Detections and Upper Limits

    Energy Technology Data Exchange (ETDEWEB)

    Tournear, Derek M

    2003-02-18

    Narayan and Heyl (2002) have developed a theoretical framework to convert suitable upper limits on type I X-ray bursts from accreting black hole candidates (BHCs) into evidence for an event horizon. However, no appropriate observational limit exists in the literature. In this paper we survey 2101.2 ks of data from the Unconventional Stellar Aspect (USA) X-ray timing experiment and 5142 ks of data from the Rossi X-ray Timing Explorer (RXTE) experiment to obtain a formal constraint of this type. 1122 ks of neutron star data yield a population averaged mean burst rate of 1.69 x 10{sup -5} bursts s{sup -1} while 6081 ks of BHC data yield a 95% confidence level upper limit of 4.9 x 10{sup -7} bursts s{sup -1}. This is the first published limit of this type for Black Hole Candidates. Applying the theoretical framework of Narayan and Heyl (2002) we calculate regions of unstable luminosity where the neutron stars are expected to burst and the BHCs would be expected to burst if they had a surface. In this unstable luminosity region 464 ks of neutron star data yield an averaged mean burst rate of 4.1 x 10{sup -5} bursts s{sup -1} and 1512 ks of BHC data yield a 95% confidence level upper limit of 2.0 x 10{sup 6} bursts s{sup -1}, and a limit of > 10 {sigma} that BHCs do not burst with a rate similar to the rate of neutron stars in these unstable regions. This gives further evidence that BHCs do not have surfaces unless there is some new physics occurring on their surface.

  6. Adenocarcinoma - chest x-ray (image)

    Science.gov (United States)

    This chest x-ray shows adenocarcinoma of the lung. There is a rounded light spot in the right upper lung (left side ... density. Diseases that may cause this type of x-ray result would be tuberculous or fungal granuloma, and ...

  7. Clinical pattern and prevalence of upper gastrointestinal toxicity in patients abusing ketamine.

    Science.gov (United States)

    Liu, Shirley Yuk Wah; Ng, Stephen Ka Kei; Tam, Yuk Him; Yee, Samuel Chi Hang; Lai, Franco Pui Tak; Hong, Cindy Yuek Lam; Chiu, Philip Wai Yan; Ng, Enders Kwok Wai; Ng, Chi Fai

    2017-09-01

    Evaluations of upper gastrointestinal toxicity from ketamine abuse are uncommon. This study investigated the clinical pattern of upper gastrointestinal symptoms in patients inhaling ketamine. In a cross-sectional study of 611 consecutive patients who were seeking treatment for ketamine uropathy in a tertiary hospital setting between August 2008 and June 2016, their clinical pattern of upper gastrointestinal symptoms was evaluated and compared with a control population of 804 non-users. A total of 168 (27.5%) patients abusing ketamine (mean age 26.3 years, 58.9% female) reported the presence of upper gastrointestinal symptoms. These symptoms were significantly more prevalent in patients inhaling ketamine than in those who were not (27.5% vs 5.2%, P ketamine abuse before symptom presentation was 5.0 ± 3.1 years. The presenting symptoms included epigastric pain (n = 155, 25.4%), recurrent vomiting (n = 48, 7.9%), anemia (n = 36, 5.9%) and gastrointestinal bleeding (n = 20, 3.3%). Uropathy symptoms were preceded by upper gastrointestinal symptoms for 4.4 ± 3.0 years in 141 (83.9%) patients. Logistic regression showed that elder age (odds ratio [OR] 1.06, P = 0.04), active abuser status (OR 1.60, P = 0.04) and longer duration of ketamine abuse (OR 1.00, P = 0.04) were independent factors associated with upper gastrointestinal toxicity. Although epigastric symptoms are unusual in the young population, upper gastrointestinal toxicity was highly prevalent in those inhaling ketamine. Enquiries about ketamine abuse are recommended when assessing young patients with epigastric symptoms. © 2017 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  8. [Gastrointestinal bleeding--concepts of surgical therapy in the upper gastrointestinal tract].

    Science.gov (United States)

    Knoefel, W T; Rehders, A

    2006-02-01

    Bleeding of the upper gastrointestinal tract is the main symptom of a variety of possible conditions and still results in considerable mortality. Endoscopy is the first diagnostic modality, enabling rapid therapeutic intervention. In case of intractable or relapsing bleeding, surgery is often inevitable. However, emergency operations result in significantly higher mortality rates. Therefore the option of early elective surgical intervention should be considered for patients at increased risk of relapsing bleeding. If bleeding is symptomatic due to a complex underlying condition such as hemosuccus pancreaticus or hemobilia, angiography is now recognized as the definitive investigation. Angiographic hemostasis can be achieved in most cases. Due to the underlying condition, surgical management still remains the mainstay in treating these patients. This paper reviews surgical strategy in handling upper gastrointestinal bleeding.

  9. Analysis on actual state of selective upper gastrointestinal study in medical examination

    International Nuclear Information System (INIS)

    Kang, Seong Ho; Son, Soon Yong; Joo, Mi Hwa; Kim, Chang Bok; Kim, Keon Chung

    1999-01-01

    The purpose of this study is to present controversial point and reform measurements by analysing factors having important effect on selection of upper gastrointestinal study in total health promotion. We examined 200 persons for this study, who visited for upper gastrointestinal study from January to February in 1999. We classified this group into Endoscopy, Upper gastrointestinal series, and sleeping endoscopy. We also investigated standard of satisfaction and factors having effect on selection of each study. As is results, in the motive of selection, Item of 'making accurate observation' and 'without pain' was 39.3% and 34.7%, respectively. In this study, sleeping endoscopy was 45.7%, but on the other side upper gastrointestinal series was low 22.6%(P<0.05). In the standard of preference of study, the man was 55.7% in the endoscopy, and the woman was 61.8% in the upper gastrointestinal series(P<0.05). The standard of preference of upper gastrointestinal series show that it was satisfied on the whole irrespective of sex, dwelling place, age, occupation, and level of education. In the selection of study, one's own will was showed the highest frequency, and family inducement was showed second(P<0.05). Persons over 60% were examined before the same study. Selection of upper gastrointestinal series was 47.9% of person with normal findings, and endoscopy and sleeping endoscopy was over 70% with gastritis, gastric and duodenal(P<0.01). For one's accurate selection of examination, it is important that objective and credible information should be given to a recipient for examination

  10. A STUDY ON ENDOSCOPIC EVALUATION OF UPPER GASTROINTESTINAL BLEEDING

    Directory of Open Access Journals (Sweden)

    Pranaya Kumar

    2016-03-01

    Full Text Available CONTEXT Upper gastrointestinal bleeding (UGIB is one of the commonest gastrointestinal emergencies encountered by clinicians. Peptic ulcers are the most common cause of UGIB. Endoscopy has become the preferred method for diagnosis in patients with acute UGIB. This study is done in a diagnostic upper gastrointestinal endoscopy (UGIE setup of a tertiary care hospital to ascertain the causes of UGIB prevalent in this part of our country which might differ from other studies. AIM To ascertain prevalent causes of UGIB in patients of this part of India admitted to a Govt. Tertiary Hospital with a provisional diagnosis of UGIB. METHOD One hundred consecutive patients with UGIB were subjected to UGIE to find out the aetiology. The clinical profile and endoscopic findings were analysed and compared with the data on UGIB from other studies. RESULTS The mean age of patients was 47.03 years with male: female ratio of 2.33:1. 58% of patients were first time bleeders. Majority of patients presented with melaena. Visualisation of active bleeding achieved to 85.7% when endoscopy was done within first 24 hrs. The commonest cause of UGIB was duodenal ulcer (DU which accounted for 41% cases. Gastric ulcer was responsible in 13% of cases. Portal hypertension was responsible for bleed in only 13%. Neoplasms accounted for 25% of cases. Other less common causes were erosive gastritis (3%, gastric polyp (3%, Mallory-Weiss tear (1%, and Dieulafoy’s lesion (1%. Among bleeding peptic ulcers, 27.8% of cases were classified as Forrest IIa and 20.4% in Forrest IIb & IIc each. Acid peptic disease was past history elicited in majority (33% followed by NSAID (26% and alcohol (26%. CONCLUSION The present study has diagnosed various causes of upper gastrointestinal bleeding in this part of country. The incidence of gastric carcinoma as a cause of upper gastrointestinal bleeding is significantly high compared to those in other studies. UGI endoscopy should be done in every case

  11. Analysis on actual state of selective upper gastrointestinal study in medical examination

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Seong Ho; Son, Soon Yong; Joo, Mi Hwa; Kim, Chang Bok; Kim, Keon Chung [Asan Medical Center, Asan (Korea, Republic of)

    1999-04-01

    The purpose of this study is to present controversial point and reform measurements by analysing factors having important effect on selection of upper gastrointestinal study in total health promotion. We examined 200 persons for this study, who visited for upper gastrointestinal study from January to February in 1999. We classified this group into Endoscopy, Upper gastrointestinal series, and sleeping endoscopy. We also investigated standard of satisfaction and factors having effect on selection of each study. As is results, in the motive of selection, Item of 'making accurate observation' and 'without pain' was 39.3% and 34.7%, respectively. In this study, sleeping endoscopy was 45.7%, but on the other side upper gastrointestinal series was low 22.6%(P<0.05). In the standard of preference of study, the man was 55.7% in the endoscopy, and the woman was 61.8% in the upper gastrointestinal series(P<0.05). The standard of preference of upper gastrointestinal series show that it was satisfied on the whole irrespective of sex, dwelling place, age, occupation, and level of education. In the selection of study, one's own will was showed the highest frequency, and family inducement was showed second(P<0.05). Persons over 60% were examined before the same study. Selection of upper gastrointestinal series was 47.9% of person with normal findings, and endoscopy and sleeping endoscopy was over 70% with gastritis, gastric and duodenal(P<0.01). For one's accurate selection of examination, it is important that objective and credible information should be given to a recipient for examination.

  12. Bleeding and starving: fasting and delayed refeeding after upper gastrointestinal bleeding.

    Science.gov (United States)

    Fonseca, Jorge; Meira, Tânia; Nunes, Ana; Santos, Carla Adriana

    2014-01-01

    Early refeeding after nonvariceal upper gastrointestinal bleeding is safe and reduces hospital stay/costs. The aim of this study was obtaining objective data on refeeding after nonvariceal upper gastrointestinal bleeding. From 1 year span records of nonvariceal upper gastrointestinal bleeding patients that underwent urgent endoscopy: clinical features; rockall score; endoscopic data, including severity of lesions and therapy; feeding related records of seven days: liquid diet prescription, first liquid intake, soft/solid diet prescription, first soft/solid intake. From 133 patients (84 men) Rockall classification was possible in 126: 76 score ≥5, 50 score bleeding, eight rebled, two underwent surgery, 13 died. Ulcer was the major bleeding cause, 63 patients underwent endoscopic therapy. There was 142/532 possible refeeding records, no record 37% patients. Only 16% were fed during the first day and half were only fed on third day or later. Rockall upper gastrointestinal bleeding patients must be refed earlier, according to guidelines.

  13. Appropriateness of Referrals for Upper Gastrointestinal Endoscopy ...

    African Journals Online (AJOL)

    Appropriateness of Referrals for Upper Gastrointestinal Endoscopy. ... Accra between January and December, 2008 were interviewed and evaluated for this study. ... Presentations with bleeding and suspicion of malignancy showed statistical ...

  14. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  15. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    2009-01-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  16. Use of health related quality of life tools in upper gastrointestinal ...

    African Journals Online (AJOL)

    The paper concludes that use of validated and reliable health instruments in upper gastrointestinal surgery is directed at measuring the impact in a reproducible and valid fashion. Curative or palliative procedures should be offered to the patients of upper gastrointestinal disorders after the assessment by HR-QOL tools.

  17. UPPER GASTROINTESTINAL ENDOSCOPY FINDINGS IN PATIENTS REFERRED WITH UPPER GASTROINTESTINAL SYMPTOMS IN ELDORET, KENYA: A RETROSPECTIVE REVIEW.

    Science.gov (United States)

    Ayuo, P O; Some, F F; Kiplagat, J

    2014-08-01

    Dyspepsia is one of the major indications for upper gastrointestinal endoscopy. Other indications include dysphagia, odynophagia and gastrointestinal bleeding. Endoscopy is an expensive procedure that is out of reach of many patients in resource constrained region such as western Kenya. We reviewed endoscopy records from both public and private health institutions spanning ten years. To determine the pattern of referral and endoscopy diagnoses in patients referred for upper gastrointestinal endoscopy in Eldoret, Kenya. Retrospective chart review. Moi Teaching and Referral Hospital, private hospitals and private clinics in Eldoret, Kenya. One thousand six hundred and ninety (1690) Patients who underwent upper GI endoscopy from 1993 to 2003 were reviewed after obtaining clearances from the respective institutions. Information on age, sex, symptoms, and endoscopy diagnosis were extracted and subjected to statistical analysis. The most common symptom was dyspepsia in 1059 (62.7%) followed by dysphagia in 224 (13.3%). Others were referred with diagnosis of cancer of the stomach or oesophagus. Common endoscopy diagnoses were cancer of the oesophagus in 199 (11.8%) and duodenal ulcer in 186 (11.0%). The majority of the patients (30.4%) had normal endoscopy findings. Of the 1059 patients with dyspepsia, only 154 (14.5%) had duodenal ulcer and 34 (3.2%) had gastric ulcers, the majority, 37.2% had normal endoscopy findings. Dyspepsia was main reason for referral, but the majority of such patients had normal findings. Cancer of the oesophagus was the main diagnosis in patients with dysphagia. In view of the cost of endoscopy, only those with dyspepsia and alarm symptoms be referred for the procedure.

  18. A retrospective study demonstrating properties of nonvariceal upper gastrointestinal bleeding in Turkey.

    Science.gov (United States)

    Bor, Serhat; Dağli, Ulkü; Sarer, Banu; Gürel, Selim; Tözün, Nurdan; Sıvrı, Bülent; Akbaş, Türkay; Sahın, Burhan; Memık, Faruk; Batur, Yücel

    2011-06-01

    Helicobacter pylori infection, non-steroidal anti-inflammatory drugs and peptic ulcer are considered as the major factors for upper gastrointestinal system bleeding. The objective of the study was to determine the sociodemographic and etiologic factors, management and outcome of patients with non-variceal upper gastrointestinal system bleeding in Turkey. Patients who admitted to hospitals with upper gastrointestinal system bleeding and in whom upper gastrointestinal endoscopy was performed were enrolled in this retrospective study. The detailed data of medical history, comorbid diseases, medications, admission to intensive care units, Helicobacter pylori infection, blood transfusion, upper gastrointestinal endoscopy, and treatment outcome were documented. The most frequent causes of bleeding (%) were duodenal ulcer (49.4), gastric ulcer (22.8), erosion (9.6), and cancer (2.2) among 1,711 lesions in endoscopic appearances of 1,339 patients from six centers. Seven hundred and four patients were evaluated for Helicobacter pylori infection and the test was positive in 45.6% of those patients. Comorbid diseases were present in 59.2% of the patients. The percentage of patients using acetylsalicylic acid and/or other non-steroidal anti-inflammatory drug was 54.3%. Bleeding was stopped with medical therapy in 66.9%. Only 3.7% of the patients underwent emergency surgery, and a 1.1% mortality rate was determined. Patients with upper gastrointestinal system bleeding were significantly older, more likely to be male, and more likely to use non-steroidal anti-inflammatory drugs. Though most of the patients were using gastro-protective agents, duodenal and gastric ulcers were the contributing factors in more than 70% of the upper gastrointestinal bleeding. The extensive use of non-steroidal anti-inflammatory drug is a hazardous health issue considering the use of these drugs in half of the patients.

  19. Upper gastrointestinal bleeding in irbid, jordan

    International Nuclear Information System (INIS)

    Banisalamah, A.A.; Mraiat, Z.M.

    2007-01-01

    To define the various causes of nonvariceal upper gastrointestinal bleeding, to outline management modalities and to determine the final outcome of patients. A retrospective analysis of patients presenting with upper gastrointestinal (UGI) bleeding from January 2003 to December 2006 (4 years) was conducted. Patients with endoscopically proven variceal bleeding were excluded. Out of the 120 patients, most of the patients belonged to an age group of more than 50 years (mean 48.5 years). Haematemesis was the most common presentation and Acute Gastric Mucosal Lesion (AGML) was the most frequently encountered lesion. The cause of bleeding was not identified in 10 patients (undetermined group). Twenty-two (18.3%) underwent surgery and we had an overall mortality of 15.8%. AGML being the leading cause can be managed conservatively most of the time. There is a male preponderance and the incidence and mortality increases with advancing age. The undetermined group remains a diagnostic problem. (author)

  20. Spironolactone use and the risk of upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Gulmez, Sinem E; Lassen, Annmarie T; Aalykke, Claus

    2008-01-01

    WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT * Recent studies have suggested an increased risk of upper gastrointestinal bleeding (UGB) in spironolactone users. * We conducted this population-based case-control study to confirm the association between spironolactone use and acute nonvaricose UGB alone...... is not modified by high cumulative doses or by concurrent use of antithrombotic or nonsteroidal anti-inflammatory drugs. AIMS Recent studies have suggested an increased risk of upper gastrointestinal bleeding (UGB) in spironolactone users. The aim was to confirm the association, identify the risk factors...

  1. Role of endoscopy in evaluating upper gastrointestinal tract lesions in rural population

    Directory of Open Access Journals (Sweden)

    Sharanabasavaraj Javali

    2015-01-01

    Full Text Available Background and Objectives: Before the advent of endoscopy direct access to the lesion for the confirmation of the diagnosis was difficult, this posed difficulty in contemplating adequate and appropriate surgery. Endoscopy as a diagnostic and therapeutic tool has grown in recent years. Upper gastrointestinal (GI endoscopy is one of the most fascinating branch which serves not only as a means of resolving or amplifying the diagnosis made clinically or by X-ray, but also a primary diagnostic procedure for conditions not otherwise diagnosable on unoperated case. Fiber optic upper GI endoscopy has already become firmly established as a reliable, quick and inexpensive tool. This study was done to detect the upper gastrointestinal lesions in rural population of Kolar District, the distribution pattern of various upper GI lesions in patients presenting with upper GI symptoms and to follow the endoscopic diagnosis for medical and surgical management. Materials and Methods: The study group includes patients reporting to outpatient department and also the inpatients in wards of General Surgery and other departments, who have upper GI symptoms, were advised endoscopy at R. L. JALAPPA Hospital and Research Centre, Kolar, from a period of December 2011 to August 2013. Results: Of the 600 cases, 370 were males, and 230 were females. Disease incidence was highest in 51-70 years age group, that is, 21.6%. Pain abdomen was the most common symptom. Epigastric tenderness was the most common sign among the patients clinically. Reflux esophagitis and diffuse gastritis formed most common cases (307 cases. The incidence of duodenitis - 7.83%, peptic ulcer -3.3%, esophageal varices - 1.5%, the incidence of carcinoma esophagus and carcinoma stomach was approximately same that is, 4.5% and 4.6% respectively. The incidence of esophageal candidiasis was 4.16%. The majority of the patients had a normal study that is, 14.5%. Conclusion: Upper GI lesions were more common in

  2. Flash x-ray cinematography

    International Nuclear Information System (INIS)

    Stein, W.E.

    1976-01-01

    Experiments intended to provide an overview of the potential capabilities and limitations of flash x-ray cinematography as a diagnostic technique for a Fast Reactor Safety Test Facility are described. The results provide estimates of the x-ray pulse intensity required to obtain adequate radiographs of an array of fuel pins in a typical reactor configuration. An estimate of the upper limit on the pulse duration imposed by the reactor background radiation was also determined. X-ray cinematography has been demonstrated at a repetition rate limited only by the recording equipment on hand at the time of these measurements. These preliminary results indicate that flash x-ray cinematography of the motion of fuel in a Fast Reactor Test Facility is technically feasible

  3. Haemorrhage from Pancreatic Pseudocysts Presenting as Upper Gastrointestinal Haemorrhage

    Directory of Open Access Journals (Sweden)

    Giuseppe Garcea

    2004-04-01

    Full Text Available Haemorrhage is a rare but frequently fatal complication of pancreatic pseudocysts. The high mortality associated with pancreatic haemorrhage makes prompt and aggressive management essential. Occasionally, haemorrhage may present atypically, leading to delay in its diagnosis and management. This report details a case of pancreatic haemorrhage presenting as an upper gastrointestinal bleed and discusses the subsequent management. When managing patients with pancreatic pseudocysts who present with the stigmata of upper gastrointestinal bleeding, the possibility that the bleeding originates from the pancreas must always be borne in mind.

  4. The effect of transcatheter arterial embolisation for nonvariceal upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Duvnjak, Stevo

    2010-01-01

    The aim of this investigation was to evaluate the clinical efficacy and safety of transcatheter arterial embolisation with coils for nonvariceal upper gastrointestinal (GI) bleeding after failed endoscopic therapy.......The aim of this investigation was to evaluate the clinical efficacy and safety of transcatheter arterial embolisation with coils for nonvariceal upper gastrointestinal (GI) bleeding after failed endoscopic therapy....

  5. Upper gastrointestinal alterations in kidney transplant candidates.

    Science.gov (United States)

    Homse Netto, João Pedro; Pinheiro, João Pedro Sant'Anna; Ferrari, Mariana Lopes; Soares, Mirella Tizziani; Silveira, Rogério Augusto Gomes; Maioli, Mariana Espiga; Delfino, Vinicius Daher Alvares

    2018-05-14

    The incidence of gastrointestinal disorders among patients with chronic kidney disease (CKD) is high, despite the lack of a good correlation between endoscopic findings and symptoms. Many services thus perform upper gastrointestinal (UGI) endoscopy on kidney transplant candidates. This study aims to describe the alterations seen on the upper endoscopies of 96 kidney-transplant candidates seen from 2014 to 2015. Ninety-six CKD patients underwent upper endoscopic examination as part of the preparation to receive kidney grafts. The data collected from the patients' medical records were charted on Microsoft Office Excel 2016 and presented descriptively. Mean values, medians, interquartile ranges and 95% confidence intervals of the clinic and epidemiological variables were calculated. Possible associations between endoscopic findings and infection by H. pylori were studied. Males accounted for 54.17% of the 96 patients included in the study. Median age and time on dialysis were 50 years and 50 months, respectively. The most frequent upper endoscopy finding was enanthematous pangastritis (57.30%), followed by erosive esophagitis (30.20%). Gastric intestinal metaplasia and peptic ulcer were found in 8.33% and 7.30% of the patients, respectively. H. pylori tests were positive in 49 patients, and H. pylori infection was correlated only with non-erosive esophagitis (P = 0.046). Abnormal upper endoscopy findings were detected in all studied patients. This study suggested that upper endoscopy is a valid procedure for kidney transplant candidates. However, prospective studies are needed to shed more light on this matter.

  6. Upper gastrointestinal symptoms in patients with advanced cancer: relationship to nutritional and performance status.

    Science.gov (United States)

    Bovio, G; Montagna, G; Bariani, C; Baiardi, P

    2009-10-01

    The goals of the study were to determine the relationship of upper gastrointestinal symptoms with nutritional status and to assess their association with performance status in patients with advanced cancer. We studied 143 patients (50 F, 93 M, mean age 68 +/- 11 years, mean body mass index 22.39 +/- 4.3 kg/m(2)). Assessed symptoms were the following: anorexia, nausea, vomiting, dysphagia for solids, dysphagia for liquids, xerostomia, hypogeusia, dysgeusia, hiccup and chewing disturbances. We determined anthropometric parameters, daily energy intake and serum albumin, prealbumin and transferrin. The most common upper gastrointestinal symptoms were xerostomia (73%), anorexia (49%) and chewing disturbances (40%). Fifty-four percent of patients had weight loss greater than 10%. Seventy-three patients (51%) had daily energy intake lower than their resting energy expenditure. Mean serum prealbumin, albumin and transferrin were below normal range. Mean Eastern Cooperative Oncology Group performance status scale was 3.1 +/- 0.49. Symptoms were often strongly correlated, and usually, patients experienced at least three upper gastrointestinal symptoms at the same time. Anorexia, nausea and vomiting were the symptoms mostly correlated with other symptoms. A correlation was found between vomiting and hiccup. Energy intake (EI) was the nutritional parameter mostly affected by upper gastrointestinal symptoms; moreover, EI is the most predictive factor of upper gastrointestinal symptoms, particularly xerostomia, anorexia and dysphagia for solids. Upper gastrointestinal symptoms are linked to nutritional parameters: In particular, energy intake represents the most predictive variable of symptom occurrence. The performance status is not affected by upper gastrointestinal symptoms. A rigorous nutritional assessment and the managing of upper gastrointestinal symptoms are crucial in patients with advanced cancer.

  7. PROPOSAL OF A CLINICAL CARE PATHWAY FOR THE MANAGEMENT OF ACUTE UPPER GASTROINTESTINAL BLEEDING.

    Science.gov (United States)

    Franco, Matheus Cavalcante; Nakao, Frank Shigueo; Rodrigues, Rodrigo; Maluf-Filho, Fauze; Paulo, Gustavo Andrade de; Libera, Ermelindo Della

    2015-12-01

    Upper gastrointestinal bleeding implies significant clinical and economic repercussions. The correct establishment of the latest therapies for the upper gastrointestinal bleeding is associated with reduced in-hospital mortality. The use of clinical pathways for the upper gastrointestinal bleeding is associated with shorter hospital stay and lower hospital costs. The primary objective is the development of a clinical care pathway for the management of patients with upper gastrointestinal bleeding, to be used in tertiary hospital. It was conducted an extensive literature review on the management of upper gastrointestinal bleeding, contained in the primary and secondary information sources. The result is a clinical care pathway for the upper gastrointestinal bleeding in patients with evidence of recent bleeding, diagnosed by melena or hematemesis in the last 12 hours, who are admitted in the emergency rooms and intensive care units of tertiary hospitals. In this compact and understandable pathway, it is well demonstrated the management since the admission, with definition of the inclusion and exclusion criteria, passing through the initial clinical treatment, posterior guidance for endoscopic therapy, and referral to rescue therapies in cases of persistent or rebleeding. It was also included the care that must be taken before hospital discharge for all patients who recover from an episode of bleeding. The introduction of a clinical care pathway for patients with upper gastrointestinal bleeding may contribute to standardization of medical practices, decrease in waiting time for medications and services, length of hospital stay and costs.

  8. [Risk for the development of upper gastrointestinal bleeding in children in an intensive care unit].

    Science.gov (United States)

    Gutiérrez-Gutiérrez, Glenda Karina; Villasís-Keever, Miguel Angel; González-Ortiz, Beatriz; Troconis-Trens, Germán; Tapia-Monge, Dora María; Flores-Calderón, Judith

    2014-01-01

    Although gastrointestinal tract bleeding can occur at any age, most studies trying to establish causes or risk factors for its development have been conducted in adults. The aim of this study was to determine risk factors in children admitted in a pediatric intensive care unit. A retrospective case-control study was conducted. Children who developed upper gastrointestinal bleeding children during their stay at the intensive care unit were considered the cases. Variables were obtained from medical records including age, sex, nutritional status, mechanical ventilation, use of nasogastric tube, development of complications, presence of coagulopathy, use of prophylaxis for upper gastrointestinal tract bleeding, fasting and use of steroids. Using a multivariate analysis, risk factors were identified, with odds ratios (OR) and 95 % confidence intervals (95 % CI) calculations. Out of 165 patients, 58 had upper gastrointestinal bleeding (35 %). Risk factors identified were prolonged clotting times (OR = 3.35), thrombocytopenia (OR = 2.39), development of sepsis (OR = 6.74) or pneumonia (OR = 4.37). Prophylaxis for upper gastrointestinal bleeding was not a protective factor. Upper gastrointestinal bleeding frequency in children hospitalized in an intensive care unit was high. Identifying risk factors should help to reduce upper gastrointestinal bleeding frequency.

  9. International prospective observational study of upper gastrointestinal haemorrhage: Does weekend admission affect outcome?

    DEFF Research Database (Denmark)

    Murray, Iain A.; Dalton, Harry R.; Stanley, Adrian J.

    2017-01-01

    Introduction Out of hours admissions have higher mortality for many conditions but upper gastrointestinal haemorrhage studies have produced variable outcomes. Methods Prospective study of 12 months consecutive admissions of upper gastrointestinal haemorrhage from four international high volume...

  10. Upper gastrointestinal endoscopic findings and prevalence of ...

    African Journals Online (AJOL)

    Upper gastrointestinal endoscopic findings and prevalence of Helicobacter pylori infection among adult patients with dyspepsia in northern Tanzania. ... Endoscopy (EGD) for initial work up. Study on antimicrobial susceptibility pattern of H. pylori is recommended to guide choices for evidence based treatment option.

  11. Emergency readmission following acute upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Strömdahl, Martin; Helgeson, Johan; Kalaitzakis, Evangelos

    2017-01-01

    OBJECTIVE: To assess the occurrence, clinical predictors, and associated mortality of all-cause emergency readmissions after acute upper gastrointestinal bleeding (AUGIB). PATIENTS AND METHODS: All patients with AUGIB from an area of 600 000 inhabitants in Sweden admitted in a single institution...

  12. Endovascular treatment of nonvariceal acute arterial upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Duvnjak, Stevo

    2010-01-01

    Transcatheter arterial embolization as treatment of upper nonvariceal gastrointestinal bleeding is increasingly being used after failed primary endoscopic treatment. The results after embolization have become better and surgery still has a high mortality. Embolization is a safe and effective...... procedure, but its use is has been limited because of relatively high rates of rebleeding and high mortality, both of which are associated with gastrointestinal bleeding and non-gastrointestinal related mortality causes. Transcatheter arterial embolization is a valuable minimal invasive method...

  13. PROPOSAL OF A CLINICAL CARE PATHWAY FOR THE MANAGEMENT OF ACUTE UPPER GASTROINTESTINAL BLEEDING

    Directory of Open Access Journals (Sweden)

    Matheus Cavalcante FRANCO

    2015-12-01

    Full Text Available Background - Upper gastrointestinal bleeding implies significant clinical and economic repercussions. The correct establishment of the latest therapies for the upper gastrointestinal bleeding is associated with reduced in-hospital mortality. The use of clinical pathways for the upper gastrointestinal bleeding is associated with shorter hospital stay and lower hospital costs. Objective - The primary objective is the development of a clinical care pathway for the management of patients with upper gastrointestinal bleeding, to be used in tertiary hospital. Methods - It was conducted an extensive literature review on the management of upper gastrointestinal bleeding, contained in the primary and secondary information sources. Results - The result is a clinical care pathway for the upper gastrointestinal bleeding in patients with evidence of recent bleeding, diagnosed by melena or hematemesis in the last 12 hours, who are admitted in the emergency rooms and intensive care units of tertiary hospitals. In this compact and understandable pathway, it is well demonstrated the management since the admission, with definition of the inclusion and exclusion criteria, passing through the initial clinical treatment, posterior guidance for endoscopic therapy, and referral to rescue therapies in cases of persistent or rebleeding. It was also included the care that must be taken before hospital discharge for all patients who recover from an episode of bleeding. Conclusion - The introduction of a clinical care pathway for patients with upper gastrointestinal bleeding may contribute to standardization of medical practices, decrease in waiting time for medications and services, length of hospital stay and costs.

  14. Conservative treatment of perforated upper gastrointestinal tract

    International Nuclear Information System (INIS)

    Naoi, Daishi; Sano, Wataru; Nakata, Yasuyuki; Yano, Kentaro; Suzuki, Takeshi; Chiku, Tsuyoshi; Tashiro, Tsuguhiko

    2009-01-01

    In order to clarify the validity of indication criteria of the conservative treatment for perforated upper gastrointestinal tract, a retrospective study was carried out. We enrolled 28 patients with perforation of the gastrointestinal tract who were determined to receive conservative treatment at the time of hospitalization from January 2000 to December 2007. When the following criteria were satisfied, we treated the patients by the conservative treatment after informed consent was gained from them and their families: stable condition of vital signs; peritoneal signs localized in the upper abdomen; and no or slight fluid collection at the Douglas' pouch determined by computed tomography. Patients who showed changes for the worse of peritonitis or increased fluid collection during follow-up were promptly converted to surgery. Six patients were converted to surgery, but all of them were discharged very much improved. We compared patient's data of the conservative treatment group and the converted surgery group at the time of consultation. All data were not statistically different between two groups. If all criteria are satisfied, it seemed that we can start conservative treatment for perforated gastrointestinal tract with careful observation and the system of prompt conversion to operation for patients who showed changes for the worse of peritonitis or increased fluid collection. (author)

  15. Do statins protect against upper gastrointestinal bleeding?

    DEFF Research Database (Denmark)

    Gulmez, Sinem Ezgi; Lassen, Annmarie Touborg; Aalykke, Claus

    2009-01-01

    AIMS: Recently, an apparent protective effect of statins against upper gastrointestinal bleeding (UGB) was postulated in a post hoc analysis of a randomized trial. We aimed to evaluate the effect of statin use on acute nonvariceal UGB alone or in combinations with low-dose aspirin and other...

  16. Radiodiagnosis of tumours of gastrointestinal tract

    International Nuclear Information System (INIS)

    Sokolov, Yu.N.; Antonovich, V.B.

    1981-01-01

    Systematic description of X-ray picture of tumours of gastrointestinal tract organs is given. The possibilities of contemporary methods of X-ray examination in their revealing are shown. Clinical and X-ray trend of tumour diagnosis is underlined. The basic and accessory symptoms are analyzed from which X-ray semiotics of tumours is turned out. The expressiveness of X-ray symptoms is shown in relation to morphological forms and localization of the tumours. Much attention is given to radiodiagnosis of early tumours of stomach. Differential diagnosis of tumours with non-tumoural diseases is given. X-ray semiotics of lesions of gastrointestinal tract organs in malignant diseases of blood system is presented [ru

  17. Rare upper gastrointestinal hemorrhage of cetuximab: A case report.

    Science.gov (United States)

    Duan, Shi-Jie; Gao, Zi-Ming; Wang, Peng-Liang; Gong, Bao-Cheng; Huang, Han-Wei; Luo, Lei; Wang, Xin; Xing, Ya-Nan; Xu, Hui-Mian; Liu, Fu-Nan

    2017-12-01

    cetuximab, an epidermal growth factor receptor inhibitor, is a targeted therapeutic regimen of colorectal cancers. Several common adverse effects have been found, such as cutaneous or gastrointestinal toxicity. However, according to the articles had been published, upper gastrointestinal bleeding (UGIB) is considered to be rare and its mechanism remains unclear. In this report, we presented a 42-year-old male patient with advanced recto-sigmoid cancer. After palliative operation, the patient suffered from complete upper gastrointestinal (GI) obstruction, which was induced by extensive abdominal metastasis of the tumor. Considering his poor condition, we chose the targeted drug, cetuximab, as his further treatment. But after the application of cetuximab, the UGIB immediately happened twice in this patient. UGIB, as a rare complication of cetuximab, occured to the patient. We stopped the bleeding with thrombin, hemocoagulase and somatostatin and suspended the subsequent treatment plan of cetuximab. At the same time, anti-shock treatment was given immediately. He was died of respiratory and circulatory failure caused by UGIB and advanced tumor eventually. UGIB should be considered as a rare but severe complication of cetuximab. When cetuximab is applied for patients with advanced colon tumors, more cautions should be required if the patients are accompanied by upper gastrointestinal obstruction. In addition, for those patients who suffered from UGIB recently, cetuximab should be prohibited if the Rockall score ranged > 5 points. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  18. Systematic review: tranexamic acid for upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Klingenberg, S.L.; Langholz, S.E.; Gluud, Lise Lotte

    2008-01-01

    BACKGROUND: Tranexamic acid may reduce upper gastrointestinal bleeding and stabilize patients before endoscopic treatments. AIM: To review randomized trials on tranexamic acid for upper gastrointestinal bleeding. METHODS: Manual and electronic searches of The Cochrane Library, MEDLINE, EMBASE...... and Science Citation Index were combined. Intention-to-treat random effect meta-analyses were performed and results presented as RRs with 95% confidence intervals. RESULTS: Seven double-blind randomized trials on tranexamic acid vs. placebo were included. Of 1754 patients randomized, 21% were excluded. Only...... one trial included endoscopic treatments or proton pump inhibitors. Five per cent of patients on tranexamic acid and 8% of controls died (RR: 0.61, 95% CI: 0.42-0.89). No significant differences were found on bleeding, bleeding-related mortality, surgery or transfusion requirements. Adverse events...

  19. Extragalactic Hard X-ray Surveys: From INTEGRAL to Simbol-X

    Science.gov (United States)

    Paltani, S.; Dwelly, T.; Walter, R.; McHardy, I. M.; Courvoisier, T. J.-L.

    2009-05-01

    We present some results of the deepest extragalactic survey performed by the INTEGRAL satellite. The fraction of very absorbed AGN is quite large. The sharp decrease in the absorption fraction with X-ray luminosity observed at lower-energy X-rays is not observed. The current lack of truly Compton-thick objects, with an upper limit of 14% to the size of this population, is just compatible with recent modeling of the cosmic X-ray background. We also study the prospects for a future hard X-ray serendipitous survey with Simbol-X. We show that Simbol-X will easily detect a large number of serendipitous AGN, allowing us to study the evolution of AGN up to redshifts about 2, opening the door to the cosmological study of hard X-ray selected AGN, which is barely possible with existing satellites like Swift and INTEGRAL.

  20. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  1. X-ray examinations pose little risk

    International Nuclear Information System (INIS)

    Servomaa, A.; Komppa, T.

    1997-01-01

    X-ray examinations account for about 15 per cent of Finns' radiation exposure and for roughly one out of a hundred deaths from cancer. The risk is small when compared to other risks in life and to the health benefits obtained from the examinations. About 4.1 million x-ray examinations were conducted in Finland in 1995, i.e. an average of 0.8 examinations per inhabitant. The mean effective dose was about 0.67 mSv per examination and about 0.54 mSv per inhabitant. Natural background radiation causes an annual radiation dose of approximately 3 mSv per person. Examinations of bones and soft tissues accounted for the highest number of x-ray images, roughly 2.1 million, of which half were examinations of the extremities. Some 1.3 million x-ray images were taken of the pulmonary organs, most of them being examinations of the lungs. Computed tomography and examinations of the gastrointestinal tract accounted for about 130,000 images each. To assess the radiation risk involved in x-ray examinations, we need knowledge or an estimate of the radiation doses of organs sensitive to radiation. Efficient calculation methods are available for this purpose. (orig.)

  2. Treatment of upper gastrointestinal fistula and leakage with personal stage nutrition support

    Institute of Scientific and Technical Information of China (English)

    Qun Wang; Zhi-Su Liu; Qun Qian; Quan Sun; Ding-Yu Pan; Yue-Ming He

    2008-01-01

    AIM: To investigate the feasibility of treatment for upper gastrointestinal fistula and leakage with personal stage nutrition support.METHODS: Forty-three patients with upper gastrointestinal fistula and leakage were randomly divided into two groups. Patients in group A were treated with personal stage nutrition support and patients in group B were treated with total parental nutrition (TPN) in combination with operation.Nutritional states of the candidates were evaluated by detecting albumin (Alb) and pre-Alb. The balance between nutrition and hepatic function was evaluated by measurement of aspartate aminotransferase (AST),alanine aminotransferase (ALT) and total bilirubin (Tbill) before and after operation. At the same time their complications and hospitalized time were surveyed.RESULTS: Personal stage nutrition support improved upper gastrointestinal fistula and leakage. The nutrition state and hepatic function were better in patients who received personal stage nutrition support than in those who did not receive TPN. There was no significant difference in the complication and hospitalized time in the two groups of patients.CONCLUSION: Upper gastrointestinal fistula and leakage can be treated with personal stage nutrition support which is more beneficial for the post-operation recovery and more economic than surgical operation.

  3. Bayesian network modelling of upper gastrointestinal bleeding

    Science.gov (United States)

    Aisha, Nazziwa; Shohaimi, Shamarina; Adam, Mohd Bakri

    2013-09-01

    Bayesian networks are graphical probabilistic models that represent causal and other relationships between domain variables. In the context of medical decision making, these models have been explored to help in medical diagnosis and prognosis. In this paper, we discuss the Bayesian network formalism in building medical support systems and we learn a tree augmented naive Bayes Network (TAN) from gastrointestinal bleeding data. The accuracy of the TAN in classifying the source of gastrointestinal bleeding into upper or lower source is obtained. The TAN achieves a high classification accuracy of 86% and an area under curve of 92%. A sensitivity analysis of the model shows relatively high levels of entropy reduction for color of the stool, history of gastrointestinal bleeding, consistency and the ratio of blood urea nitrogen to creatinine. The TAN facilitates the identification of the source of GIB and requires further validation.

  4. Upper gastrointestinal bleeding in severely burned patients: a case-control study to assess risk factors, causes, and outcome.

    Science.gov (United States)

    Kim, Young Jin; Koh, Dong Hee; Park, Se Woo; Park, Sun Man; Choi, Min Ho; Jang, Hyun Joo; Kae, Sea Hyub; Lee, Jin; Byun, Hyun Woo

    2014-01-01

    To determine the risk factors, causes, and outcome of clinically important upper gastrointestinal bleeding that occurs in severely burned patients. The charts of all patients admitted to the burn intensive care unit were analyzed retrospectively over a 4-year period (from January 2006 to December 2009). Cases consisted of burned patients who developed upper gastrointestinal bleeding more than 24 hours after admission to the burn intensive care unit. Controls were a set of patients, in the burn intensive care unit, without upper gastrointestinal bleeding matched with cases for age and gender. Cases and controls were compared with respect to the risk factors of upper gastrointestinal bleeding and outcomes. During the study period, clinically important upper gastrointestinal bleeding occurred in 20 patients out of all 964 patients. The most common cause of upper gastrointestinal bleeding was duodenal ulcer (11 of 20 cases, 55%). In the multivariate analysis, mechanical ventilation (p = 0.044) and coagulopathy (p = 0.035) were found to be the independent predictors of upper gastrointestinal bleeding in severely burned patients. Upper gastrointestinal hemorrhage tends to occur more frequently after having prolonged mechanical ventilation and coagulopathy.

  5. Adverse effects of anticoagulation treatment: clinically significant upper gastrointestinal hemorrhage

    Directory of Open Access Journals (Sweden)

    Pavel Skok

    2006-12-01

    Full Text Available Background: Over the last years, the use of oral anticoagulant treatment has increased dramatically, principally for the prevention of venous thrombosis and thrombembolic events. This treatment is demanding, especially among the elderly with concommitant diseases and different medication. Aim of the study to evaluate the rate of serious complications, clinically significant hemorrhage from upper gastointestinal tract in patients treated with oral antiocoagulants in a prospective cohort study.Patients and methods: Included were patients admitted to our institution between January 1, 1994 and December 31, 2003 due to gastrointestinal hemorrhage. Emergency endoscopy and laboratory testing was performed in all patients.Results: 6416 patients were investigated: 2452 women (38.2 % and 3964 men (61.8 %, mean age 59.1 years, SD 17.2. Among our patients, 55 % were aged over 60 years. In 86.4 % of patients the source of bleeding was confirmed in the upper gastrointestinal tract. In the last week prior to bleeding, 20.4 % (1309/6416 of all patients were regularly taking nonsteroidal anti-inflammatory drugs, anticoagulant therapy or antiplatelet agents in single daily doses at least. 6.3 % of patients (82/1309 with abundant hemorrhage from upper gastrointestinal tract were using oral anticoagulant therapy and had INR > 5 at admission, 25.6 % of them had INR > 10. The mortality of patients using oral anticoagulants and INR > 5 was 17.1 %.Conclusions: Upper gastrointestinal hemorrhage is a serious complication of different medications, particularly in elderly patients. Safe use of anticoagulant therapy is based on careful selection of patients and correct intake of the prescribed drugs.

  6. Transcatheter arterial embolization for upper gastrointestinal tract bleeding.

    Science.gov (United States)

    Širvinskas, Audrius; Smolskas, Edgaras; Mikelis, Kipras; Brimienė, Vilma; Brimas, Gintautas

    2017-12-01

    Transcatheter arterial embolization is a possible treatment for patients with recurrent bleeding from the upper gastrointestinal tract after failed endoscopic management and is also an alternative to surgical treatment. To analyze the outcomes of transcatheter arterial embolization and identify the clinical and technical factors that influenced the rates of morbidity and mortality. A retrospective analysis was carried out, based on the data of 36 patients who underwent transcatheter arterial embolization for acute nonvariceal upper gastrointestinal bleeding in 2013 to 2015 in our center. An analysis was performed between early rebleeding rates, mortality and the following factors: patient sex, age, number of units of packed red blood cells and packed plasma administered to the patients, length of hospital stay, therapeutic or prophylactic embolization. The technical success rate of the embolization procedure was 100%. There were 15 (41.70%) therapeutic embolizations and 21 (58.3%) prophylactic embolizations. There was a 77.8% clinical success rate. Following embolization, 10 (27.80%) patients had repeated bleeding and 9 (25.0%) patients died. Significant associations were found between rebleeding and prophylactic embolization (OR = 10.53; p = 0.04) and between mortality and prophylactic embolization (OR = 10.53; p = 0.04) and units of packed red blood cells (OR = 1.25; p < 0.01). In our experience, transcatheter arterial embolization is a safe treatment method for acute nonvariceal upper gastrointestinal bleeding and a possible alternative to surgery for high-risk patients.

  7. An upper gastrointestinal ulcer still bleeding after endoscopy : what comes next?

    NARCIS (Netherlands)

    Craenen, E. M. E.; Hofker, Hendrik; Peters, Frans; Kater, G. M.; Glatman, K. R.; Zijlstra, J. G.

    Introduction: Recurrent bleeding from an upper gastrointestinal ulcer when endoscopy fails is a reason for radiological or surgical treatment, both of which have their advantages and disadvantages. Case: Based on a patient with recurrent gastrointestinal bleeding, we reviewed the available evidence

  8. High-energy X-ray observations of extragalactic objects

    International Nuclear Information System (INIS)

    Pietsch, W.; Reppin, C.; Truemper, J.; Voges, W.; Lewin, W.; Kendziorra, E.; Staubert, R.

    1981-01-01

    During a balloon flight from Alice Springs, Australia, six extragalactic sources which are known as potential X-ray sources have been observed in hard X-rays (E > 20 keV). We present X-ray spectra of 3C 273 and Cen-A as well as upper limits on 3C 120, MKN 509, NGC 5506, and MR 2251-178. (orig.)

  9. Hemospray for treatment of acute bleeding due to upper gastrointestinal tumours.

    Science.gov (United States)

    Arena, Monica; Masci, Enzo; Eusebi, Leonardo Henry; Iabichino, Giuseppe; Mangiavillano, Benedetto; Viaggi, Paolo; Morandi, Elisabetta; Fanti, Lorella; Granata, Antonino; Traina, Mario; Testoni, Pier Alberto; Opocher, Enrico; Luigiano, Carmelo

    2017-05-01

    Hemospray is a new endoscopic haemostatic powder that can be used in the management of upper gastrointestinal bleedings. To assess the efficacy and safety of Hemospray as monotherapy for the treatment of acute upper gastrointestinal bleeding due to cancer. The endoscopy databases of 3 Italian Endoscopic Units were reviewed retrospectively and 15 patients (8 males; mean age 74 years) were included in this study. Immediate haemostasis was achieved in 93% of cases. Among the successful cases, 3 re-bled, one case treated with Hemospray and injection had a good outcome, while 2 cases died both re-treated with Hemospray, injection and thermal therapy. No complications related to Hemospray occurred. Finally, 80% of patients had a good clinical outcome at 30days and 50% at six months. Hemospray may be considered an effective and safe method for the endoscopic management of acute neoplastic upper gastrointestinal bleedings. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Endoscopic Findings of Upper Gastrointestinal Involvement in Primary Vasculitis.

    Science.gov (United States)

    Gong, Eun Jeong; Kim, Do Hoon; Chun, Joo Hyun; Ahn, Ji Yong; Choi, Kwi-Sook; Jung, Kee Wook; Lee, Jeong Hoon; Choi, Kee Don; Song, Ho June; Lee, Gin Hyug; Jung, Hwoon-Yong; Kim, Jin Ho; Song, In Hye; Kim, Yong-Gil

    2016-07-15

    Gastrointestinal involvement in vasculitis may result in life-threatening complications. However, its variable clinical presentations and endoscopic features, and the rarity of the disease, often result in delayed diagnosis. Clinical characteristics, endoscopic features, and histopathological findings were reviewed from medical records. Of 6,477 patients with vasculitis, 148 were diagnosed as primary vasculitis with upper gastrointestinal involvement. Of these, 21 cases (14.2%) were classified as large-vessel vasculitis, 17 cases (11.5%) as medium-vessel vasculitis, and 110 cases (74.3%) as small-vessel vasculitis. According to the specific diagnosis, IgA vasculitis (Henoch-Schönlein purpura) was the most common diagnosis (56.8%), followed by Takayasu arteritis (14.1%), microscopic polyangiitis (10.1%), and polyarteritis nodosa (6.8%). Gastrointestinal symptoms were present in 113 subjects (76.4%), with abdominal pain (78.8%) the most common symptom. Erosion and ulcers were striking endoscopic features, and the second portion of the duodenum was the most frequently involved site. Biopsy specimens were obtained from 124 patients, and only eight (5.4%) presented histopathological signs of vasculitis. Diagnosis of vasculitis involving the upper gastrointestinal tract is difficult. Because of the widespread use of endoscopy, combining clinical features with endoscopic findings may facilitate making appropriate diagnoses; however, the diagnostic yield of endoscopic biopsy is low.

  11. Upper gastrointestinal symptoms in autoimmune gastritis: A cross-sectional study.

    Science.gov (United States)

    Carabotti, Marilia; Lahner, Edith; Esposito, Gianluca; Sacchi, Maria Carlotta; Severi, Carola; Annibale, Bruno

    2017-01-01

    Autoimmune gastritis is often suspected for its hematologic findings, and rarely the diagnosis is made for the presence of gastrointestinal symptoms. Aims of this cross-sectional study were to assess in a large cohort of patients affected by autoimmune gastritis the occurrence and the pattern of gastrointestinal symptoms and to evaluate whether symptomatic patients are characterized by specific clinical features.Gastrointestinal symptoms of 379 consecutive autoimmune gastritis patients were systematically assessed and classified following Rome III Criteria. Association between symptoms and anemia pattern, positivity to gastric autoantibodies, Helicobacter pylori infection, and concomitant autoimmune disease were evaluated.In total, 70.2% of patients were female, median age 55 years (range 17-83). Pernicious anemia (53.6%), iron deficiency anemia (34.8%), gastric autoantibodies (68.8%), and autoimmune disorders (41.7%) were present. However, 56.7% of patients complained of gastrointestinal symptoms, 69.8% of them had exclusively upper symptoms, 15.8% only lower and 14.4% concomitant upper and lower symptoms. Dyspepsia, subtype postprandial distress syndrome was the most represented, being present in 60.2% of symptomatic patients. Univariate and multivariate analyses showed that age gastritis is associated in almost 60% of cases with gastrointestinal symptoms, in particular dyspepsia. Dyspepsia is strictly related to younger age, no smoking, and absence of anemia.

  12. A study of clinical and endoscopic profile of acute upper, gastrointestinal bleeding.

    Science.gov (United States)

    Dewan, K R; Patowary, B S; Bhattarai, S

    2014-01-01

    Acute Upper Gastrointestinal Bleeding is a common medical emergency with a hospital mortality of approximately 10 percent. Higher mortality rate is associated with rebleeding. Rockall scoring system identifies patients at higher risk of rebleed and mortality. To study the clinical and endoscopic profile of acute upper gastrointestinal bleed to know the etiology, clinical presentation, severity of bleeding and outcome. This is a prospective, descriptive hospital based study conducted in Gastroenterology unit of College of Medical Sciences and Teaching Hospital, Bharatpur, Nepal from January 2012 to January 2013. It included 120 patients at random presenting with manifestations of upper gastrointestinal bleed. Their clinical and endoscopic profiles were studied. Rockall scoring system was used to assess their prognosis. Males were predominant (75%). Age ranged from 14 to 88 years, mean being 48.76+17.19. At presentation 86 patients (71.7%) had both hematemesis and malena, 24 patients (20%) had only malena and 10 patients (8.3%) had only hematemesis. Shock was detected in 21.7%, severe anemia and high blood urea were found in 34.2% and 38.3% respectively. Upper Gastrointestinal Bleeding endoscopy revealed esophageal varices (47.5%), peptic ulcer disease (33.3%), erosive mucosal disease (11.6%), Mallory Weiss tear (4.1%) and malignancy (3.3%). Median hospital stay was 7.28+3.18 days. Comorbidities were present in 43.3%. Eighty six patients (71.7%) had Rockall score 6. Five patients (4.2%) expired. Risk factors for death being massive rebleeeding, comorbidities and Rockall score >6. Acute Upper Gastrointestinal bleeding is a medical emergency. Mortality is associated with massive bleeding, comorbidities and Rockall score >6. Urgent, appropriate hospital management definitely helps to reduce morbidity and mortality.

  13. Upper gastrointestinal bleeding: Five-year experience from one centre

    Directory of Open Access Journals (Sweden)

    Jovanović Ivan

    2008-01-01

    Full Text Available Introduction Acute upper gastrointestinal bleeding is the commonest emergency managed by gastroenterologists. Objective To assess the frequency of erosive gastropathy and duodenal ulcer as a cause of upper gastrointestinal (GI bleeding as well as its relation to age, gender and known risk factors. METHOD We conducted retrospective observational analysis of emergency endoscopy reports from the records of the Emergency Department of Clinic for Gastroenterology and Hepatology, Clinical Centre of Serbia, during the period from 2000 to 2005. Data consisted of patients' demographics, endoscopic findings and potential risk factors. Results During the period 2000-2005, three thousand nine hundred and fifty four emergency upper endoscopies were performed for acute bleeding. In one quarter of cases, acute gastric erosions were the actual cause of bleeding. One half of them were associated with excessive consumption of salicylates and NSAIDs. In most of the examined cases, bleeding stopped spontaneously, while 7.6% of the cases required endoscopic intervention. Duodenal ulcer was detected as a source of bleeding in 1320 (33.4% patients and was significantly associated with a male gender (71.8% and salicylate or NSAID abuse (59.1% (χ2-test; p=0.007. Conclusion Erosive gastropathy and duodenal ulcer represent a significant cause of upper gastrointestinal bleeding accounting for up to 60% of all cases that required emergency endoscopy during the 5- year period. Consumption of NSAIDs and salicylates was associated more frequently with bleeding from a duodenal ulcer than with erosive gastropathy leading to a conclusion that we must explore other causes of erosive gastropathy more thoroughly. .

  14. Influencing the practice and outcome in acute upper gastrointestinal haemorrhage. Steering Committee of the National Audit of Acute Upper Gastrointestinal Haemorrhage.

    Science.gov (United States)

    Rockall, T A; Logan, R F; Devlin, H B; Northfield, T C

    1997-11-01

    To assess changes in practice and outcome in acute upper gastrointestinal haemorrhage following the feedback of data, the reemphasis of national guidelines, and specific recommendations following an initial survey. A prospective, multicentre, audit cycle. Forty five hospitals from three health regions participated in two phases of the audit cycle. Phase I: 2332 patients with acute upper gastrointestinal haemorrhage; phase II: 1625 patients with upper gastrointestinal haemorrhage. Patients were evaluated with respect to management (with reference to the recommendations in the national guidelines), mortality, and length of hospital stay. Following the distribution of data from the first phase of the National Audit and the formulation of specific recommendations for improving practice, the proportion of hospitals with local guidelines or protocols for the management of upper gastrointestinal haemorrhage rose from 71% (32/45) to 91% (41/45); 12 of the 32 hospitals with guidelines during the first phase revised their guidelines following the initial survey. There was a small but significant increase in the proportion of all patients who underwent endoscopy (from 81% to 86%), the proportion who underwent endoscopy within 24 hours of admission (from 50% to 56%), and the use of central venous pressure monitoring in patients with organ failure requiring blood transfusion or those with profound shock (from 30% to 43%). There was, however, no change in the use of high dependency beds or joint medical/surgical management in high risk cases. There was no significant change in crude or risk standardised mortality (13.4% in the first phase and 14.4% in the second phase). Although many of the participating hospitals have made efforts to improve practice by producing or updating guidelines or protocols, there has been only a small demonstrable change in some areas of practice during the National Audit. The failure to detect any improvement in mortality may reflect this lack of

  15. Vitamin K for upper gastrointestinal bleeding in people with acute or chronic liver diseases.

    Science.gov (United States)

    Martí-Carvajal, Arturo J; Solà, Ivan

    2015-06-09

    Upper gastrointestinal bleeding is one of the most frequent causes of morbidity and mortality in the course of liver cirrhosis. Several treatments are used for upper gastrointestinal bleeding in people with liver diseases. One of them is vitamin K administration, but it is not known whether it benefits or harms people with acute or chronic liver disease and upper gastrointestinal bleeding. This is an update of this Cochrane review. To assess the beneficial and harmful effects of vitamin K for people with acute or chronic liver disease and upper gastrointestinal bleeding. We searched The Cochrane Hepato-Biliary Controlled Trials Register (February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (Issue 2 of 12, 2015), MEDLINE (Ovid SP) (1946 to February 2015), EMBASE (Ovid SP) (1974 to February 2015), Science Citation Index EXPANDED (1900 to February 2015), and LILACS (1982 to 25 February 2015). We sought additional randomised trials from two registries of clinical trials: the World Health Organization Clinical Trials Search Portal and the metaRegister of Controlled Trials. We looked through the reference lists of the retrieved publications and review articles. Randomised clinical trials irrespective of blinding, language, or publication status for assessment of benefits and harms. We considered observational studies for assessment of harms only. \\We aimed to summarise data from randomised clinical trials using Standard Cochrane methodology and assess them according to the GRADE approach. We found no randomised trials on vitamin K for upper gastrointestinal bleeding in people with liver diseases assessing benefits and harms of the intervention. We identified no quasi-randomised studies, historically controlled studies, or observational studies assessing harms. This updated review found no randomised clinical trials of vitamin K for upper gastrointestinal bleeding in people with liver diseases. The benefits and harms of vitamin K need to be tested

  16. Upper Gastrointestinal Stent Insertion in Malignant and Benign Disorders

    Science.gov (United States)

    Kang, Hyoun Woo

    2015-01-01

    Upper gastrointestinal (GI) stents are increasingly being used to manage upper GI obstructions. Initially developed for palliative treatment of esophageal cancer, upper GI stents now play an emerging role in benign strictures of the upper GI tract. Because recurrent obstruction and stent-related complications are common, new modifications of stents have been implemented. Self-expandable metal stents (SEMS) have replaced older plastic stents. In addition, newly designed SEMS have been developed to prevent complications. This review provides an overview of the various types, indications, methods, complications, and clinical outcomes of upper GI stents in a number of malignant and benign disorders dividing the esophagus and gastroduodenum. PMID:26064817

  17. Upper limits of a cosmic infrared background flux as determined by X- and gamma-ray observations on M87

    International Nuclear Information System (INIS)

    Schlickeiser, R.; Cambridge Univ.; Harwit, M.; Cornell Univ., Ithaca, NY

    1982-01-01

    Upper limits on the energy density of infrared photons in the radio lobe regions of M87 are derived using measurements of the X-ray and gamma-ray emission. The calculations are based on an inverse Compton scattering model initiated by radio-flux producing electrons. It is shown that the energy density of infrared photons in the radio lobe regions is similar than 2 eV cm -3 . (orig.)

  18. Risk stratification in upper gastrointestinal bleeding; prediction, prevention and prognosis

    NARCIS (Netherlands)

    de Groot, N.L.

    2013-01-01

    In the first part of this thesis we developed a novel prediction score for predicting upper gastrointestinal (GI) bleeding in both NSAID and low-dose aspirin users. Both for NSAIDs and low-dose aspirin use risk scores were developed by identifying the five most dominant predictors. The risk of upper

  19. Transcatheter arterial embolisation in upper gastrointestinal bleeding in a sample of 29 patients in a gastrointestinal referral center in Germany.

    Science.gov (United States)

    Heining-Kruz, S; Finkenzeller, T; Schreyer, A; Dietl, K H; Kullmann, F; Paetzel, C; Schedel, J

    2015-09-01

    This is a retrospective analysis of interventional embolisation performed with catheter angiography in 29 patients with upper gastrointestinal bleeding in the setting of a secondary care hospital. From April 2007 to February 2013, 29 patients with upper gastrointestinal bleeding underwent endovascular diagnostics and treatment. The diagnosis was established by endoscopy, computed tomography or clinically based on a significant decrease in hemoglobin. Transcatheter arterial embolisation was performed with coils, liquid embolic agents, and particles. The technical and clinical outcomes were assessed by postinterventional endoscopy, hemoglobin concentrations, number of necessary transfusions, or surgical interventions, as well as by post-interventional mortality within 28 days after the procedure. Selective angiographic embolisation in upper gastrointestinal bleeding was primarily successful technically and clinically in 22 of 29 patients. In 4/29 cases an angiographic reintervention was performed, which was successful in 3 cases. In 3 cases of primarily technically unsuccessful procedures reintervention was not attempted. No catheterisation-related complications were recorded. Peri-interventional mortality was 31%, but only 2 of these patients died due to uncontrolled massive bleeding, whereas the lethal outcome in the other 7 patients was due to their underlying diseases. Transcatheter arterial embolisation is an effective and rapid method in the management of upper gastrointestinal bleeding. Radiological endovascular interventions may considerably contribute to reduced mortality in GI bleeding by avoiding a potential surgical procedure following unsuccessful endoscopic treatment. The study underlines the importance of the combination of interventional endoscopy with interventional radiology in secondary care hospitals for patient outcome in complex and complicated upper gastrointestinal bleeding situations. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Discharge hemoglobin and outcome in patients with acute nonvariceal upper gastrointestinal bleeding

    Science.gov (United States)

    Lee, Jae Min; Kim, Eun Sun; Chun, Hoon Jai; Hwang, Young-Jae; Lee, Jae Hyung; Kang, Seung Hun; Yoo, In Kyung; Kim, Seung Han; Choi, Hyuk Soon; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2016-01-01

    Background and study aims: Many patients with acute gastrointestinal bleeding present with anemia and frequently require red blood cell (RBC) transfusion. A restrictive transfusion strategy and a low hemoglobin (Hb) threshold for transfusion had been shown to produce acceptable outcomes in patients with acute upper gastrointestinal bleeding. However, most patients are discharged with mild anemia owing to the restricted volume of packed RBCs (pRBCs). We investigated whether discharge Hb influences the outcome in patients with acute nonvariceal upper gastrointestinal bleeding. Patients and methods: We retrospectively analyzed patients with upper gastrointestinal bleeding who had received pRBCs during hospitalization between January 2012 and January 2014. Patients with variceal bleeding, malignant lesion, stroke, or cardiovascular disease were excluded. We divided the patients into 2 groups, low (8 g/dL ≤ Hb  10 g/dL. Patients in the low Hb group had a lower consumption of pRBCs and shorter hospital stay than did those in the high Hb group. The Hb levels were not fully recovered at outpatient follow-up until 7 days after discharge; however, most patients showed Hb recovery at 45 days after discharge. The rate of rebleeding after discharge was not significantly different between the 2 groups. Conclusions: In patients with acute upper gastrointestinal bleeding, a discharge Hb between 8 and 10 g/dL was linked to favorable outcomes on outpatient follow-up. Most patients recovered from anemia without any critical complication within 45 days after discharge. PMID:27540574

  1. Pancreatic Gastrointestinal Stromal Tumor after Upper Gastrointestinal Hemorrhage and Performance of Whipple Procedure: A Case Report and Literature Review.

    Science.gov (United States)

    Aziret, Mehmet; Çetinkünar, Süleyman; Aktaş, Elife; İrkörücü, Oktay; Bali, İlhan; Erdem, Hasan

    2015-08-03

    Gastrointestinal stromal tumors (GISTs) are the most common mesenchymal tumors in the gastrointestinal system. These types of tumors originate from any part of the tract as well as from the intestine, colon, omentum, mesentery or retroperitoneum. GIST is a rare tumor compared to other types of tumors, accounting for less than 1% of all gastrointestinal tumors. A 56-year-old male patient was hospitalized due to an upper gastrointestinal hemorrhage and the start of abdominal pain on the same day. In the upper gastrointestinal endoscopy that was performed, a solitary mass was found in the second section of the duodenum and a blood vessel (Forrest type 2a) was seen. The extent and location of the mass was detected by abdominal tomography. After hemodynamic recovery, a Whipple procedure was performed without any complications. A subsequent histopathological examination detected a c-kit-positive (CD117) pancreatic GIST with high mitotic index. The most effective treatment method for GISTs is surgical resection. In patients with a head of pancreatic GIST, the Whipple procedure can be used more safely and effectively.

  2. Predictors for the need for endoscopic therapy in patients with presumed acute upper gastrointestinal bleeding.

    Science.gov (United States)

    Kim, Su Sun; Kim, Kyung Up; Kim, Sung Jun; Seo, Seung In; Kim, Hyoung Su; Jang, Myoung Kuk; Kim, Hak Yang; Shin, Woon Geon

    2017-12-15

    Selecting patients with an urgent need for endoscopic hemostasis is difficult based only on simple parameters of presumed acute upper gastrointestinal bleeding. This study assessed easily applicable factors to predict cases in need of urgent endoscopic hemostasis due to acute upper gastrointestinal bleeding. The consecutively included patients were divided into the endoscopic hemostasis and nonendoscopic hemostasis groups. We reviewed the enrolled patients' medical records and analyzed various variables and parameters for acute upper gastrointestinal bleeding outcomes such as demographic factors, comorbidities, symptoms, signs, laboratory findings, rebleeding rate, and mortality to evaluate simple predictive factors for endoscopic treatment. A total of 613 patients were analyzed, including 329 patients in the endoscopic hemostasis and 284 patients in the non-endoscopic hemostasis groups. In the multivariate analysis, a bloody nasogastric lavage (adjusted odds ratio [AOR], 6.786; 95% confidence interval [CI], 3.990 to 11.543; p upper gastrointestinal bleeding.

  3. Laparoscopic jejunostomy for obstructing upper gastrointestinal malignancies

    Science.gov (United States)

    TSUJIMOTO, HIRONORI; HIRAKI, SHUICHI; TAKAHATA, RISA; NOMURA, SHINSUKE; ITO, NOZOMI; KANEMATSU, KYOHEI; HORIGUCHI, HIROYUKI; AOSASA, SUEFUMI; YAMAMOTO, JUNJI; HASE, KAZUO

    2015-01-01

    The aim of this study was to describe a minimally invasive laparoscopic jejunostomy (Lap-J) technique for obstruction due to upper gastrointestinal malignancies and evaluate the nutritional benefit of Lap-J during neoadjuvant chemotherapy (NAC) in cases with obstructing esophageal cancer. Under general anesthesia, the jejunum 20–30 cm distant from the Treitz ligament was pulled out through an extended umbilical laparoscopic incision and a jejunal tube was inserted to 30 cm. The loop of bowel was gently returned to the abdomen and the feeding tube was drawn through the abdominal wall via the left lower incision. The jejunum was then laparoscopically sutured to the anterior abdominal wall. Lap-J was performed in 26 cases. The median operative time was 82 min. The postoperative course was uneventful. Lap-J prior to NAC was not associated with a decrease in body weight or serum total protein during NAC, compared with patients who received NAC without Lap-J. This minimally invasive jejunostomy technique may be particularly useful in patients in whom endoscopic therapy is not feasible due to obstruction from upper gastrointestinal malignancies. PMID:26807238

  4. Endoscopic findings of upper gastrointestinal bleeding in patients with liver cirrhosis

    International Nuclear Information System (INIS)

    Hadayat, R.; Rehman, A.U.; Gandapur, A.

    2015-01-01

    Acute upper gastrointestinal (GI) bleeding is a common medical emergency. A common risk factor of upper GI bleeding is cirrhosis of liver, which can lead to variceal haemorrhage. 30-40% of cirrhotic patients who bleed may have non-variceal upper GI bleeding and it is frequently caused by peptic ulcers, portal gastropathy, Mallory-Weiss tear, and gastro-duodenal erosions. The objective of this study was to determine the frequency of upper gastrointestinal endoscopic findings among patients presenting with upper gastrointestinal bleeding with liver cirrhosis. Methods: This descriptive cross-sectional study was carried out in Gastroenterology and Hepatology Department of Ayub Teaching Hospital, Abbottabad from February 2012 to June 2013. 252 patients diagnosed with cirrhosis, presenting with upper GI bleed, age ?50 years of either gender, and were included in the study. Non-probability consecutive sampling was used. Endoscopy was performed on each patient and the findings documented. Results: The mean age was 57.84 ± 6.29 years. There were 158 (62.7%) males and 94 (37.3%) females. The most common endoscopic finding was oesophageal varices (92.9%, n=234) followed by portal hypertensive gastropathy (38.9%, n=98) with almost equal distribution among males and females. Gastric varices were found in 33.3% of patients (n=84). Among other non-variceal lesions, peptic ulcer disease was seen in 26 patients (10.3%) while gastric erosions were found in 8 patients (3.2%). Conclusion: In patients with acute upper GI bleeding and liver cirrhosis, the most common endoscopic finding is oesophageal varices, with a substantially higher value in our part of the country, apart from other non-variceal causes. (author)

  5. ENDOSCOPIC FINDINGS OF UPPER GASTROINTESTINAL BLEEDING IN PATIENTS WITH LIVER CIRROSIS.

    Science.gov (United States)

    Hadayat, Rania; Jehangiri, Attique-ur-Rehman; Gul, Rahid; Khan, Adil Naseer; Said, Khalid; Gandapur, Asadullah

    2015-01-01

    Acute upper gastrointestinal (GI) bleeding is a common medical emergency. A common risk factor of upper GI bleeding is cirrhosis of liver, which can lead to variceal haemorrhage. 30-40% of cirrhotic patients who bleed may have non-variceal upper GI bleeding and it is frequently caused by peptic ulcers, portal gastropathy, Mallory-Weiss tear, and gastroduodenal erosions. The objective of this study was to determine the frequency of upper gastrointestinal endoscopic findings among patients presenting with upper gastrointestinal bleeding with liver cirrhosis. This descriptive cross-sectional study was carried out in Gastroenterology & Hepatology Department of Ayub Teaching Hospital, Abbottabad from February 2012 to June 2013. 252 patients diagnosed with cirrhosis, presenting with upper GI bleed, age 50 years of either gender, and were included in the study. Non-probability consecutive sampling was used, Endoscopy was performed on each patient and the findings documented. The mean age was 57.84 +/- 6.29 years. There were 158 (62.7%) males and 94 (37.3%) females. The most common endoscopic finding was oesophageal varices (92.9%, n=234) followed by portal hypertensive gastropathy (38.9%, n=98) with almost equal distribution among males and females. Gastric varices were found in 33.3% of patients (n=84). Among other non-variceal lesions, peptic ulcer disease was seen in 26 patients (10.3%) while gastric erosions were found in 8 patients (3.2%). In patients with acute upper GI bleeding and liver cirrhosis, the most common endoscopic finding is oesophageal varices, with a substantially higher value in our part of the country, apart from other non-variceal causes.

  6. Textbook on X-ray diagnostics. Substantiated by Marianne Zimmer-Brossy. 6. new rev. ed.

    International Nuclear Information System (INIS)

    Becht, Stefanie; Bittner, Roland C.; Ohmstede, Anke; Pfeiffer, Andreas; Rossdeutscher, Reinhard

    2008-01-01

    The standard textbook on x-ray diagnostics has been revised by the MTRA team and radiologists: The book covers the following topics: General information: the profession of a radiologist, the x-ray department, radiation protection, quality assurance, basic physics, x-ray imaging, analog and digital image processing, archives, image interpretation. Skeleton diagnostics; Inner organs (thorax organs, neck, abdomen, gastrointestinal tract, colon, gall bladder and biliary tract): Special x-ray diagnostic methods: x-ray diagnostic of the female and male chest, x-ray diagnostics of bone joints (arthrography, and contrast media), x-ray diagnostics of the urinary-genital system, x-ray diagnostics of cavities and syrinx, x-ray diagnostics of arteries (arteriography, angiography), percutaneous transluminal angioplasty, x-ray diagnostics of veins (phlebography), x-ray diagnostics of lymphatic vessels and lymph nodes, x-ray diagnostics of spinal cord (myelography); Specific imaging methods: computerized tomography [de

  7. THERMAL X-RAY EMISSION FROM THE SHOCKED STELLAR WIND OF PULSAR GAMMA-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Zabalza, V.; Paredes, J. M. [Departament d' Astronomia i Meteorologia, Institut de Ciencies del Cosmos (ICC), Universitat de Barcelona (IEEC-UB), Marti i Franques 1, E08028 Barcelona (Spain); Bosch-Ramon, V., E-mail: vzabalza@am.ub.es [Dublin Institute for Advanced Studies, 31 Fitzwilliam Place, Dublin 2 (Ireland)

    2011-12-10

    Gamma-ray-loud X-ray binaries are binary systems that show non-thermal broadband emission from radio to gamma rays. If the system comprises a massive star and a young non-accreting pulsar, their winds will collide producing broadband non-thermal emission, most likely originated in the shocked pulsar wind. Thermal X-ray emission is expected from the shocked stellar wind, but until now it has neither been detected nor studied in the context of gamma-ray binaries. We present a semi-analytic model of the thermal X-ray emission from the shocked stellar wind in pulsar gamma-ray binaries, and find that the thermal X-ray emission increases monotonically with the pulsar spin-down luminosity, reaching luminosities of the order of 10{sup 33} erg s{sup -1}. The lack of thermal features in the X-ray spectrum of gamma-ray binaries can then be used to constrain the properties of the pulsar and stellar winds. By fitting the observed X-ray spectra of gamma-ray binaries with a source model composed of an absorbed non-thermal power law and the computed thermal X-ray emission, we are able to derive upper limits on the spin-down luminosity of the putative pulsar. We applied this method to LS 5039, the only gamma-ray binary with a radial, powerful wind, and obtain an upper limit on the pulsar spin-down luminosity of {approx}6 Multiplication-Sign 10{sup 36} erg s{sup -1}. Given the energetic constraints from its high-energy gamma-ray emission, a non-thermal to spin-down luminosity ratio very close to unity may be required.

  8. Cerebral gas embolism due to upper gastrointestinal endoscopy.

    Science.gov (United States)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E

    2009-07-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of oesophageal cancer. During the procedure, cerebral gas emboli developed resulting in an acute left-sided hemiparesis. After hyperbaric oxygen therapy, the patient recovered almost completely. The aetiology and treatment is discussed based on the reviewed literature. Once cerebral gas emboli are recognized, patient outcome can be improved by hyperbaric oxygen therapy.

  9. Radionuclide studies in upper gastro-intestinal ulceration - are they reliable

    International Nuclear Information System (INIS)

    Carstens, A.J.; Iturralde, M.; Fourie, P.A.; Pilloy, W.; Van Wyk, A.

    1985-01-01

    Endoscopy is at present the diagnostic technique of choice in the evaluation and detection of upper gastro-intestinal tract ulceration. Because of the physical discomfort, suffered by patients during endoscopic examination, the search for better and less invasive methods of examination (especially in the unco-operative and seriously ill patient) continues. According to reports from the Orient, sucralfate (Ulsanic; Continental Ethicals) has prominent ulceravid properties. These properties are being used in conjunction with a tagging agent, in this case technetium-99m, as a diagnostic method for the detection and localization of upper gastro-intestinal ulceration. In this pilot study on 6 patients the positive findings of others regarding the specificity and promise of this method could not be confirmed

  10. Endoscopic findings in upper gastrointestinal bleeding patients at Lacor hospital, northern Uganda.

    Science.gov (United States)

    Alema, O N; Martin, D O; Okello, T R

    2012-12-01

    Upper gastrointestinal bleeding (UGIB) is a common emergency medical condition that may require hospitalization and resuscitation, and results in high patient morbidity. Upper gastrointestinal endoscopy is the preferred investigative procedure for UGIB because of its accuracy, low rate of complication, and its potential for therapeutic interventions. To determine the endoscopic findings in patients presenting with UGIB and its frequency among these patients according to gender and age in Lacor hospital, northern Uganda. The study was carried out at Lacor hospital, located at northern part of Uganda. The record of 224 patients who underwent endoscopy for upper gastrointestinal bleeding over a period of 5 years between January 2006 and December 2010 were retrospectively analyzed. A total of 224 patients had endoscopy for UGIB which consisted of 113 (50.4%) males and 111 (49.6%) females, and the mean age was 42 years ± SD 15.88. The commonest cause of UGIB was esophagealvarices consisting of 40.6%, followed by esophagitis (14.7%), gastritis (12.6%) and peptic ulcer disease (duodenal and gastric ulcers) was 6.2%. The malignant conditions (gastric and esophageal cancers) contributed to 2.6%. Other less frequent causes of UGIB were hiatus hernia (1.8), duodenitis (0.9%), others-gastric polyp (0.4%). Normal endoscopic finding was 16.1% in patients who had UGIB. Esophageal varices are the commonest cause of upper gastrointestinal bleeding in this environment as compared to the west which is mainly peptic ulcer disease.

  11. Antiplatelet agents and/or anticoagulants are not associated with worse outcome following nonvariceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Teles-Sampaio, Elvira; Maia, Luís; Salgueiro, Paulo; Marcos-Pinto, Ricardo; Dinis-Ribeiro, Mário; Pedroto, Isabel

    2016-11-01

    Nonvariceal upper gastrointestinal bleeding emerges as a major complication of using antiplatelet agents and/or anticoagulants and represents a clinical challenge in patients undergoing these therapies. To characterize patients with nonvariceal upper gastrointestinal bleeding related to antithrombotics and their management, and to determine clinical predictors of adverse outcomes. Retrospective cohort of adults who underwent upper gastrointestinal endoscopy after nonvariceal upper gastrointestinal bleeding from 2010 to 2012. The outcomes were compared between patients exposed and not exposed to antithrombotics. Five hundred and forty-eight patients with nonvariceal upper gastrointestinal bleeding (67% men; mean age 66.5 ± 16.4 years) were included, of which 43% received antithrombotics. Most patients had comorbidities. Peptic ulcer was the main diagnosis and endoscopic therapy was performed in 46% of cases. The 30-day mortality rate was 7.7% (n = 42), and 36% were bleeding-related. The recurrence rate was 9% and 14% of patients with initial endoscopic treatment needed endoscopic retreatment. There were no significant differences between the exposed and non-exposed groups in most outcomes. Co-morbidities, hemodynamic instability, high Rockall score, low hemoglobin (7.76 ± 2.72 g/dL) and higher international normalized ratio (1.63 ± 1.13) were associated significantly with mortality in a univariate analysis. Adverse outcomes were not associated with antithrombotic use. The management of nonvariceal upper gastrointestinal bleeding constitutes a challenge to clinical performance optimization and clinical cooperation.

  12. Upper gastrointestinal strictures: The results of balloon dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kil Woo; Lim, Hyo Keun; Choo, In Wook; Bae, Sang Hoon; Yoon, Jong Sup [Hallym University College of Medicine, Seoul (Korea, Republic of); Yoo, Hyung Sik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Balloon catheter dilatation of upper gastrointestinal strictures is an accepted mode of therapy. The authors report the balloon dilatation in 11 consecutive patients. The lesions treated included 10 benign strictures, and 1 esophageal cancer. Esophageal balloon were ranged from 2 mm in diameter, 4 cm in length, to 30 mm in diameter, 8 cm in length. Inflation was held for from 30 to 60 seconds and then repeated two or three times during each session. The balloons were inflated to pressure of from 2 to 12 atmospheres. There were from 1 to 13 dilatations. Two esophageal perforations were occurred in one esophagitis patient and other lye stricture patient. Two perforations were not required any surgical repair. All dilatation were performed without anesthesia. All strictures were responded immediately to dilatation. Prolonged course of treatment were needed with chronic severe esophagitis, lye stricture, gastrojejunostomy with chemotherapy, as a result, all patients, except esophageal cancer, could take regular diet after balloon catheter dilatation. Balloon catheter dilatation of upper gastrointestinal stenosis was effective and safe. It should be considered before other methods of treatment applicable.

  13. X-ray diffraction and X-ray standing-wave study of the lead stearate film structure

    Energy Technology Data Exchange (ETDEWEB)

    Blagov, A. E.; Dyakova, Yu. A.; Kovalchuk, M. V.; Kohn, V. G.; Marchenkova, M. A.; Pisarevskiy, Yu. V.; Prosekov, P. A., E-mail: prosekov@crys.ras.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2016-05-15

    A new approach to the study of the structural quality of crystals is proposed. It is based on the use of X-ray standing-wave method without measuring secondary processes and considers the multiwave interaction of diffraction reflections corresponding to different harmonics of the same crystallographic reflection. A theory of multiwave X-ray diffraction is developed to calculate the rocking curves in the X-ray diffraction scheme under consideration for a long-period quasi-one-dimensional crystal. This phase-sensitive method is used to study the structure of a multilayer lead stearate film on a silicon substrate. Some specific structural features are revealed for the surface layer of the thin film, which are most likely due to the tilt of the upper layer molecules with respect to the external normal to the film surface.

  14. Transcatheter arterial embolization for acute nonvariceal upper gastrointestinal bleeding: Indications, techniques and outcomes.

    Science.gov (United States)

    Loffroy, R; Favelier, S; Pottecher, P; Estivalet, L; Genson, P Y; Gehin, S; Cercueil, J P; Krausé, D

    2015-01-01

    Over the past three decades, transcatheter arterial embolization has become the first-line therapy for the management of acute nonvariceal upper gastrointestinal bleeding that is refractory to endoscopic hemostasis. Advances in catheter-based techniques and newer embolic agents, as well as recognition of the effectiveness of minimally invasive treatment options, have expanded the role of interventional radiology in the treatment of bleeding for a variety of indications. Transcatheter arterial embolization is a fast, safe, and effective minimally invasive alternative to surgery, when endoscopic treatment fails to control acute bleeding from the upper gastrointestinal tract. This article describes the role of arterial embolization in the management of acute nonvariceal upper gastrointestinal bleeding and summarizes the literature evidence on the outcomes of endovascular therapy in such a setting. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  15. Rare cause of upper gastrointestinal bleeding owing to hepatic cancer invasion: a case report.

    Science.gov (United States)

    Wu, Wei-Ding; Wu, Jia; Yang, Hong-Guo; Chen, Yuan; Zhang, Cheng-Wu; Zhao, Da-Jian; Hu, Zhi-Ming

    2014-09-21

    Upper gastrointestinal bleeding refers to bleeding that arises from the gastrointestinal tract proximal to the ligament of Treitz. The primary reason for gastrointestinal bleeding associated with hepatocellular carcinoma is rupture of a varicose vein owing to pericardial hypotension. We report a rare case of gastrointestinal bleeding with hepatocellular carcinoma in a patient who presented with recurrent gastrointestinal bleeding. The initial diagnosis was gastric cancer with metastasis to the multiple lymph nodes of the lesser curvature. The patient underwent exploratory laparotomy, which identified two lesions in the gastric wall. Total gastrectomy and hepatic local excision was then performed. Pathological results indicated that the hepatocellular carcinoma had invaded the stomach directly, which was confirmed immunohistochemically. The patient is alive with a disease-free survival of 1 year since the surgery. Hepatocellular carcinoma with gastric invasion should be considered as a rare cause of upper gastrointestinal bleeding in hepatocellular carcinoma patients, especially with lesions located in the left lateral hepatic lobe. Surgery is the best solution.

  16. Interventional studies of the upper gastrointestinal tract

    International Nuclear Information System (INIS)

    Shapiro, B.; Gross, M.D.

    1985-01-01

    Nuclear Medicine studies of the upper gastrointestinal (GI) tract provide a means whereby physiologic and pathophysiologic features can be observed from a unique and noninvasive perspective. While nuclear medicine studies by their very nature lack the high spatial resolution of the radiographic approach, the data derived are readily quantitated and presented in numerical fashion to provide functional and dynamic information in which the influences of interventions may be observed. This chapter outlines the scope of such interventions in studies of the upper GI tract with emphasis on examinations for gastroesophageal reflux and gastric emptying. The interactions of nutrients, physical maneuvers of pharmacologic agents on nuclear medicine studies of the upper GI tract may be intentional to render a test more sensitive or to evaluate the effect of therapy, or may represent an unintentional side effect that must be taken into account if misinterpretation is to be avoided

  17. [Sedation with intravenous midazolam during upper gastrointestinal endoscopy--changes in hemodynamics, oxygen saturation and memory].

    Science.gov (United States)

    Mizuno, Ju; Matsuki, Michiko; Gouda, Yoshinori; Nishiyama, Tomoki; Hanaoka, Kazuo

    2003-09-01

    Cardiorespiratory adverse effects are often observed in patients undergoing upper gastrointestinal endoscopy with sedation. In this study, we examined hemodynamics, oxygen saturation and memory during upper gastrointestinal endoscopy under sedation with intravenous midazolam. Eight healthy outpatients without any obvious complications received intravenous midazolam 5 mg for sedation for upper gastrointestinal endoscopy. Blood pressure, heart rate and percutaneous arterial oxygen saturation (SpO2) were measured before, during and after endoscopy. After the arousal by intravenous flumazenil, we inquired the patients about the level of memory during the endoscopy. Blood pressure decreased significantly two minutes after midazolam administration, but increased significantly after the insertion of an endoscope which was not different from the control value. Heart rate increased significantly one and three minutes after the insertion of the endoscope. SpO2 decreased significantly after midazolam administration and stayed at around 95%. No patients remembered the procedure. Sedation with intravenous midazolam during upper gastrointestinal endoscopy is useful to control the cardiovascular responses, and to obtain amnesia. However, a decrease in SpO2 should be watched carefully.

  18. Axion mass limits from pulsar x rays

    International Nuclear Information System (INIS)

    Morris, D.E.

    1984-12-01

    Axions thermally emitted by a neutron star would be converted into x rays in the strong magnetic field surrounding the star. An improvement in the observational upper limit of pulsed x rays from the Vela pulsar (PSR 0833-45) by a factor of 12 would constrain the axion mass M/sub a/ -3 eV if the core is non-superfluid and at temperature T/sub c/ greater than or equal to 2 x 10 8 K. If the core is superfluid throughout, an improvement factor of 240 would be needed to provide the same constraint on the axion mass, while in the absence of superfluidity, an improvement factor of 200 could constrain M/sub a/ -4 eV. A search for modulated hard x rays from PSR 1509-58 or other young pulsars at presently attainable sensitivities may enable the setting of an upper limit for the axion mass. Observation of hard x rays from a very young hot pulsar with T/sub c/ greater than or equal to 7 x 10 8 K could set a firm bound on the axion mass, since neutron superfluidity is not expected above this temperature. The remaining axion mass range 6 x 10 -4 eV > M/sub a/ > 10 -5 eV (the cosmological lower bound) can be covered by an improved Sikivie type laboratory cavity detector for relic axions constituting the galactic halo. 48 refs

  19. Oligometastatic Disease in Upper Gastrointestinal Cancer - How to Proceed?

    Science.gov (United States)

    Chiapponi, Costanza; Berlth, Felix; Plum, Patrick S; Betzler, Christopher; Stippel, Dirk L; Popp, Felix; Bruns, Christiane J

    2017-03-01

    In the present study we review and discuss the current evidence and suggest how to proceed in the management of oligometastatic disease in upper gastrointestinal cancer. An electronic search of the PubMed database for relevant articles was performed. Both the search for 'oligometastasis', 'oligometastases', 'oligometastatic', 'oligometastatic disease' as well as 'esophageal' and 'esophageal cancer' and the search for 'oligometastasis', 'oligometastases', 'oligometastatic', 'oligometastatic disease' as well as 'gastric', 'gastric cancer', 'stomach', and 'stomach cancer' yielded very few studies. Most data need to be extrapolated in general studies on oligometastatic diseases of different origins. No randomized controlled trial could be found. In the absence of data to formulate recommendations on how to proceed in the treatment of oligometastatic disease in upper gastrointestinal cancer, a more aggressive treatment of oligometastatic disease can be considered in patients whose tumors show a more favorable neoplastic behavior after the 'test of time'. The RENAISSANCE study will certainly deliver important data regarding this aspect.

  20. Association of Proton Pump Inhibitors with Reduced Risk of Warfarin-related Serious Upper Gastrointestinal Bleeding

    Science.gov (United States)

    Ray, Wayne A.; Chung, Cecilia P.; Murray, Katherine T.; Smalley, Walter E.; Daugherty, James R.; Dupont, William D.; Stein, C. Michael

    2016-01-01

    Background & Aims Proton-pump inhibitors (PPIs) might reduce the risk of serious warfarin-related upper gastrointestinal bleeding, but the evidence of their efficacy for this indication is limited. A gastroprotective effect of PPIs would be particularly important for patients who take warfarin with antiplatelet drugs or nonselective non-steroidal anti-inflammatory drugs (NSAIDs), which further increase the risk of gastrointestinal bleeding. Methods This retrospective cohort study of patients beginning warfarin treatment in Tennessee Medicaid and the 5% National Medicare Sample identified 97,430 new episodes of warfarin treatment with 75,720 person-years of follow up. The study endpoints were hospitalizations for upper gastrointestinal bleeding potentially preventable by PPIs and for bleeding at other sites. Results Patients who took warfarin without PPI co-therapy had 119 hospitalizations for upper gastrointestinal bleeding per 10,000 person-years of treatment. The risk decreased by 24% among patients who received PPI co-therapy (adjusted hazard ratio [HR], 0.76; 95% CI, 0.63–0.91). There was no significant reduction in the risk of other gastrointestinal bleeding hospitalizations (HR, 1.07; 95% CI, 0.94–1.22) or non-gastrointestinal bleeding hospitalizations (HR, 0.98; 95% CI, 0.84–1.15) in this group. Among patients concurrently using antiplatelet drugs or NSAIDs, those without PPI co-therapy had 284 upper gastrointestinal bleeding hospitalizations per 10,000 person-years of warfarin treatment. The risk decreased by 45% (HR, 0.55; 95% CI, 0.39–0.77) with PPI co-therapy. PPI co-therapy had no significant protective effect for warfarin patients not using antiplatelet drugs or NSAIDs (HR, 0.86; 95% CI, 0.70-1.06). Findings were similar in both study populations. Conclusions In an analysis of patients beginning warfarin treatment in Tennessee Medicaid and the 5% National Medicare Sample, PPI co-therapy was associated with reduced risk of warfarin-related upper

  1. A splenic artery aneurysm presenting with multiple episodes of upper gastrointestinal bleeding: a case report.

    Science.gov (United States)

    De Silva, W S L; Gamlaksha, D S; Jayasekara, D P; Rajamanthri, S D

    2017-05-03

    Splenic artery aneurysm is rare and its diagnosis is challenging due to the nonspecific nature of the clinical presentation. We report a case of a splenic artery aneurysm in which the patient presented with chronic dyspepsia and multiple episodes of minor intragastric bleeding. A 60-year-old, previously healthy Sri Lankan man presented with four episodes of hematemesis and severe dyspeptic symptoms over a period of 6 months. The results of two initial upper gastrointestinal endoscopies and an abdominal ultrasound scan were unremarkable. A third upper gastrointestinal endoscopy detected a pulsatile bulge at the posterior wall of the gastric antrum. A contrast-enhanced computed tomogram of his abdomen detected a splenic artery aneurysm measuring 3 × 3 × 2.5 cm. While awaiting routine surgery, he developed a torrential upper gastrointestinal bleeding and shock, leading to emergency laparotomy. Splenectomy and en bloc resection of the aneurysm with the posterior stomach wall were performed. Histology revealed evidence for a true aneurysm without overt, acute, or chronic inflammation of the surrounding gastric mucosa. He became completely asymptomatic 2 weeks after the surgery. Splenic artery aneurysms can result in recurrent upper gastrointestinal bleeding. The possibility of impending catastrophic bleeding should be remembered when managing patients with splenic artery aneurysms after a minor bleeding. Negative endoscopy and ultrasonography should require contrast-enhanced computed tomography to look for the cause of recurrent upper gastrointestinal bleeding.

  2. Measurement of X-ray beam emittance using crystal optics at an X-ray undulator beamline

    CERN Document Server

    Kohmura, Y; Awaji, M; Tanaka, T; Hara, T; Goto, S; Ishikawa, T

    2000-01-01

    We present a method of using crystal optics to measure the emittance of the X-ray source. Two perfect crystals set in (++) configuration work as a high-resolution collimator. The phase-space diagram (i.e. beam cross-section and angular distribution) could be determined without any assumptions on the light source. When the measurement is done at short wavelength radiation from undulator, the electron beam emittance is larger than the diffraction limit of the X-rays. Therefore, the electron beam emittance could be estimated. The measurement was done with the hard X-rays of 18.5 and 55 keV from an undulator beamline, BL 47XU, of SPring-8. The horizontal emittance of the X-ray beam was estimated to be about 7.6 nmrad, close to the designed electron beam emittance of the storage ring (7 nmrad). Some portions of the instrumental functions, such as the scattering by filters and windows along the beamline and the slight bent of the crystal planes of the monochromator, could not be precisely evaluated, but an upper li...

  3. Concepts and controversies in disorders of upper gastrointestinal tract

    African Journals Online (AJOL)

    The upper gastrointestinal tract is one part of the digestive system where tremendous innovations and advancements in knowledge have been recorded in the last several decades. The discovery of Helicobacter pylori by Warren and Marshal in 1983 and the introduction of Rome process for the classification, diagnosis and ...

  4. Risk of upper and lower gastrointestinal bleeding in patients taking nonsteroidal anti-inflammatory drugs, antiplatelet agents, or anticoagulants.

    Science.gov (United States)

    Lanas, Ángel; Carrera-Lasfuentes, Patricia; Arguedas, Yolanda; García, Santiago; Bujanda, Luis; Calvet, Xavier; Ponce, Julio; Perez-Aísa, Ángeles; Castro, Manuel; Muñoz, Maria; Sostres, Carlos; García-Rodríguez, Luis A

    2015-05-01

    Treatment with nonsteroidal anti-inflammatory drugs (NSAIDs) or low-dose aspirin is associated with increased risk of upper gastrointestinal bleeding. There is little evidence on the risk of lower gastrointestinal bleeding with NSAIDs, antiplatelet agents (APAs), or anticoagulants. We aimed to quantify the relative risk (RR) of upper and lower gastrointestinal bleeding associated with use of NSAIDs, APAs, or anticoagulants. We performed a case-control study that used data collected from consecutive patients hospitalized for gastrointestinal bleeding (563 upper, mean age, 63.6 ± 16.7 years and 415 lower, mean age, 70.8 ± 13.8 years), confirmed by endoscopy or other diagnostic procedures. Unhospitalized patients were used as controls (n = 1008) and matched for age, hospital, and month of admission. Drug use was considered current when taken within 7 days or less before hospitalization. RRs and 95% confidence intervals (CIs) were estimated by unconditional logistic regression analysis. Use of anticoagulants, low-dose aspirin, and other drugs (non-aspirin-APA, 82.3% thienopiridines) was associated with upper and lower gastrointestinal bleeding; the risk was 2-fold higher for anticoagulants (RR, 4.2; 95% CI, 2.9-6.2) than for low-dose aspirin (RR, 2.1; 95% CI, 1.4-3.3) or other non-aspirin-APA drugs (RR, 2.0; 95% CI, 1.6-2.6). NSAID use was also associated with increased risk of gastrointestinal bleeding and greater for upper (RR, 2.6; 95% CI, 2.0-3.5) than lower gastrointestinal bleeding (RR, 1.4; 95% CI, 1.0-1.9). Use of proton pump inhibitors was associated with reduced risk of upper, but not lower, gastrointestinal bleeding. Anticoagulants, low-dose aspirin, NSAIDs, and other non-aspirin-APA drugs are associated with increased risk of upper and lower gastrointestinal bleeding. Use of anticoagulants appears to be the strongest risk factor for gastrointestinal bleeding. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  5. Chemical protection against gastrointestinal radiation injury in mice by WR 2822, WR 2823, or WR 109342 after 4 MeV x ray or fission neutron irradiation

    International Nuclear Information System (INIS)

    Connor, A.M.; Sigdestad, C.P.

    1982-01-01

    Three compounds were tested for their radioprotective properties against the effects of 4 MeV X rays or fission neutron irradiation. The endpoints tested were lethality, intestinal crypt survival, and DNA synthesizing cellularity. Two of the compounds tested; S-2(4-aminobutylamino) ethylphosphorothioc acid (WR 2822) and the aminopentylamino derivative (WR 109342). All drugs were administered via intraperitoneal injections at their approximately maximum tolerated dose. WR 2822 was shown to have a slight protective effect against X rays and neutrons. The dose modification factor (DMF) for gastrointestinal death (LD/sub 50(6)/) was 1.23 for X rays and 1.51 for neutrons. The assay for intestinal crypt survival produced DMF's of 1.44 (X rays) and 1.4 (neutrons). WR 2823 also showed a protective action in these assays. The DMF for LD/sub 50(6)/ was 1.32 (X rays) and 1.42 (neutrons). WR 109342 was found to be extremely toxic and had no significant protective effects. All three drugs were more toxic and demonstrated less protection in most of these assays than the benchmark radioprotective agent WR 2721, although WR 2822 protected against lethal effects of fission neutrons almost as well as WR 2721. Both WR 2822 and WR 2823 produced greater protection in the crypt survival assays for fission neutron irradiation than WR 2721

  6. Duodenal plexiform fibromyxoma as a cause of obscure upper gastrointestinal bleeding: A case report.

    Science.gov (United States)

    Moris, Demetrios; Spanou, Evangelia; Sougioultzis, Stavros; Dimitrokallis, Nikolaos; Kalisperati, Polyxeni; Delladetsima, Ioanna; Felekouras, Evangelos

    2017-01-01

    We are reporting the first-to our knowledge-case of duodenal Plexiform Fibromyxoma causing obscure upper gastrointestinal bleeding. Plexiform fibromyxoma triggered recurrent upper gastrointestinal bleeding episodes in a 63-year-old man who remained undiagnosed, despite multiple hospitalizations, extensive diagnostic workups and surgical interventions (including gastrectomies), for almost 17 years. During hospitalization for the last bleeding episode, an upper gastrointestinal endoscopy revealed an intestinal hemorrhagic nodule. The lesion was deemed unresectable by endoscopic means. An abdominal computerized tomography disclosed no further lesions and surgery was decided. The lesion at operation was found near the edge of the duodenal stump and treated with pancreas-preserving duodenectomy (1st and 2nd portion). Postoperative recovery was mainly uneventful and a 20-month follow-up finds the patient in good health with no need for blood transfusions.Plexiform fibromyxomas stand for a rare and widely unknown mesenchymal entity. Despite the fact that they closely resemble other gastrointestinal tumors, they distinctly vary in clinical management as well as the histopathology. Clinical awareness and further research are compulsory to elucidate its clinical course and prognosis.

  7. Shielding of the child's head during x-ray studies

    International Nuclear Information System (INIS)

    Tolmach, Eh.U.

    1985-01-01

    Three devices for X-ray shielding of child's head are suggested; the first one is a protective attachment for shielding a child being in horizontal position on an X-ray table; the second one is a protective stand for shielding head and body at roentgenofraphy of upper extremities of a child sitting near the X-ray table; the third one is a prot ctive suspension for shielding the head of a child being in vertical position

  8. Upper Gastrointestinal (GI) Tract X-Ray (Radiography)

    Science.gov (United States)

    ... the area being examined by making it appear dark (or by electronically reversing the image contrast to ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  9. Method and apparatus for enhanced sensitivity filmless medical x-ray imaging, including three-dimensional imaging

    Science.gov (United States)

    Parker, Sherwood

    1995-01-01

    A filmless X-ray imaging system includes at least one X-ray source, upper and lower collimators, and a solid-state detector array, and can provide three-dimensional imaging capability. The X-ray source plane is distance z.sub.1 above upper collimator plane, distance z.sub.2 above the lower collimator plane, and distance z.sub.3 above the plane of the detector array. The object to be X-rayed is located between the upper and lower collimator planes. The upper and lower collimators and the detector array are moved horizontally with scanning velocities v.sub.1, v.sub.2, v.sub.3 proportional to z.sub.1, z.sub.2 and z.sub.3, respectively. The pattern and size of openings in the collimators, and between detector positions is proportional such that similar triangles are always defined relative to the location of the X-ray source. X-rays that pass through openings in the upper collimator will always pass through corresponding and similar openings in the lower collimator, and thence to a corresponding detector in the underlying detector array. Substantially 100% of the X-rays irradiating the object (and neither absorbed nor scattered) pass through the lower collimator openings and are detected, which promotes enhanced sensitivity. A computer system coordinates repositioning of the collimators and detector array, and X-ray source locations. The computer system can store detector array output, and can associate a known X-ray source location with detector array output data, to provide three-dimensional imaging. Detector output may be viewed instantly, stored digitally, and/or transmitted electronically for image viewing at a remote site.

  10. Management of Upper Gastrointestinal Bleeding Due to NSAID Gastropathy That is Unresponsive to Ranitidine

    OpenAIRE

    Erawati, Lusy; Ridho, Sayid; Nainggolan, Ginova; Syam, Ari Fahrial; Manan, Chudahman

    2003-01-01

    Non steroidal anti-inflammatory drugs (NSAIDS) are now commonly used in clinical practice. On the other hands, this drug could result severe complication such as bleeding and perforation. In such condition, proton pump inhibitor can be used to stop bleeding than H2 antagonists. We reported one cases of upper gastrointestinal bleeding due to NSAID gastropathy that was unresponsive to Ranitidine. The treatment was suitable to proton pump inhibitor that could overcome upper gastrointestinal blee...

  11. Effects of Ramadan fasting on common upper gastrointestinal disorders: A review of the literature

    Directory of Open Access Journals (Sweden)

    Najmeh Seifi

    2017-03-01

    Full Text Available Introduction: Ramadan is the ninth month of Muslim's calendar during which Muslims fast. Ramadan lasts 29-30 days based on the visual sightings of the crescent moon. Fasting during Ramadan has significant health effects. The present study aimed at reviewing the literature of the impact of Ramadan fasting on upper gastrointestinal disorders. Methods: MEDLINE and Google Scholar were searched  by using ((“Ramadan” R   fasting” AND( "Upper Gastrointestinal Tract" OR "Gastrointestinal Diseases" OR "Dyspepsia" OR "Gastroesophageal Reflux"  OR "Peptic Ulcer" OR "Gastrointestinal Hemorrhage" as keywords in the title and abstract. Relevant, non- duplicate full articles written in English were reviewed. Results: Gastric acid and pepsin secretion increase during Ramadan fasting, probably associated with dyspeptic symptoms. Regarding peptic ulcer frequency, results are inconsistent. However, peptic ulcer complications such as gastrointestinal bleeding and peptic ulcer perforation increase during Ramadan fasting. Conclusion: Fasting during Ramadan seems to be beneficial for healthy individuals, but in people with gastrointestinal disorders, it might be harmful as it increases the risk of complications. Therefore, taking medical advice before Ramadan fasting is highly recommended to people suffering from gastrointestinal symptoms.

  12. Density of alkaline magmas at crustal and upper mantle conditions by X-ray absorption

    Science.gov (United States)

    Seifert, R.; Malfait, W.; Petitgirard, S.; Sanchez-Valle, C.

    2011-12-01

    Silicate melts are essential components of igneous processes and are directly involved in differentiation processes and heat transfer within the Earth. Studies of the physical properties of magmas (e.g., density, viscosity, conductivity, etc) are however challenging and experimental data at geologically relevant pressure and temperature conditions remain scarce. For example, there is virtually no data on the density at high pressure of alkaline magmas (e.g., phonolites) typically found in continental rift zone settings. We present in situ density measurements of alkaline magmas at crustal and upper mantle conditions using synchrotron X-ray absorption. Measurements were conducted on ID27 beamline at ESRF using a panoramic Paris-Edinburgh Press (PE Press). The starting material is a synthetic haplo-phonolite glass similar in composition to the Plateau flood phonolites from the Kenya rift [1]. The glass was synthesized at 1673 K and 2.0 GPa in a piston-cylinder apparatus at ETH Zurich and characterized using EPMA, FTIR and density measurements. The sample contains less than 200 ppm water and is free of CO2. Single-crystal diamond cylinders (Øin = 0.5 mm, height = 1 mm) were used as sample containers and placed in an assembly formed by hBN spacers, a graphite heater and a boron epoxy gasket [2]. The density was determined as a function of pressure (1.0 to 3.1 GPa) and temperature (1630-1860 K) from the X-ray absorption contrast at 20 keV between the sample and the diamond capsule. The molten state of the sample during the data collection was confirmed by X-ray diffraction measurements. Pressure and temperature were determined simultaneously from the equation of state of hBN and platinum using the the double isochor method [3].The results are combined with available density data at room conditions to derive the first experimental equation of state (EOS) of phonolitic liquids at crustal and upper mantle conditions. We will compare our results with recent reports of the

  13. Associated Factors of Atrophic Gastritis Diagnosed by Double-Contrast Upper Gastrointestinal Barium X-Ray Radiography: A Cross-Sectional Study Analyzing 6,901 Healthy Subjects in Japan

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Shimamoto, Takeshi; Minatsuki, Chihiro; Takahashi, Yu; Nakayama, Chiemi; Matsuda, Rie; Fujishiro, Mitsuhiro; Konno-Shimizu, Maki; Kato, Jun; Kodashima, Shinya; Ono, Satoshi; Niimi, Keiko; Mochizuki, Satoshi; Tsuji, Yosuke; Sakaguchi, Yoshiki; Asada-Hirayama, Itsuko; Takeuchi, Chihiro; Yakabi, Seiichi; Kakimoto, Hikaru; Wada, Ryoichi; Mitsushima, Toru; Ichinose, Masao; Koike, Kazuhiko

    2014-01-01

    Background Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP) infection. Methods We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach. Results Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880). These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β) and odds ratio (OR) demonstrated that serum HP IgG (β = 1.499, OR = 4.48), current smoking (β = 0.526, OR = 1.69), age (β = 0.401, OR = 1.49), low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40), and male gender (β = 0.306, OR = 1.36) showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (pgastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9%) and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%), which are not significantly different from gastric acid suppressant-free subjects. Conclusions The presence of UGI-XR-based atrophic gastritis is positively associated with

  14. Associated factors of atrophic gastritis diagnosed by double-contrast upper gastrointestinal barium X-ray radiography: a cross-sectional study analyzing 6,901 healthy subjects in Japan.

    Science.gov (United States)

    Yamamichi, Nobutake; Hirano, Chigaya; Shimamoto, Takeshi; Minatsuki, Chihiro; Takahashi, Yu; Nakayama, Chiemi; Matsuda, Rie; Fujishiro, Mitsuhiro; Konno-Shimizu, Maki; Kato, Jun; Kodashima, Shinya; Ono, Satoshi; Niimi, Keiko; Mochizuki, Satoshi; Tsuji, Yosuke; Sakaguchi, Yoshiki; Asada-Hirayama, Itsuko; Takeuchi, Chihiro; Yakabi, Seiichi; Kakimoto, Hikaru; Wada, Ryoichi; Mitsushima, Toru; Ichinose, Masao; Koike, Kazuhiko

    2014-01-01

    Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR) is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP) infection. We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach. Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880). These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β) and odds ratio (OR) demonstrated that serum HP IgG (β = 1.499, OR = 4.48), current smoking (β = 0.526, OR = 1.69), age (β = 0.401, OR = 1.49), low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40), and male gender (β = 0.306, OR = 1.36) showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (p<0.0001). Contrastively, UGI-XR-based atrophic gastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9%) and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%), which are not significantly different from gastric acid suppressant-free subjects. The presence of UGI-XR-based atrophic gastritis is positively

  15. A 12 years audit of upper gastrointestinal endoscopic procedures

    International Nuclear Information System (INIS)

    Khurram, M.; Khaar, H.B.; Hasan, Z.; Umar, M.; Javed, S.; Asghar, T.; Minhas, Z.; Akbar, A.; Atta, N.; Nassar, F.; Sultana, Q.; Pervaiz, A.; Masoom, A.

    2003-01-01

    Objective: Evaluation of upper gastrointestinal (GI) endoscopy in terms of indications, diagnostic efficacy, and diseases diagnosed. Results: Of the 8481 patients, 4935 (58.2%) were female and 3546 (41.8%) male. Mean patient age was 40.5 years. Dyspepsia (42.6%), upper GI bleed (32.8%), and evaluation of chronic liver disease (10.2%) were common indications of the procedure. An endoscopic diagnosis was possible in 82.6% patients. Varices, gastritis, duodenitis, and combined lesions were common endoscopic diagnosis. Gastritis and duodenitis were most frequent causes of upper GI bleed. We noted more gastric ulcers compared to duodenal ulcers. Females had significantly more normal endoscopies, p-value = 0.02. Conclusion: Upper GI endoscopy is an effective procedure. Dyspepsia evaluation is commonest indication for upper GI endoscopy in our patients. Etiology of upper GI bleed, and incidence of duodenal ulcer compared to gastric ulcer in our patients are different than described in literature. Females have significantly more normal endoscopies. (author)

  16. Thirty-Day Readmission Among Patients With Non-variceal Upper Gastrointestinal Hemorrhage and Effects on Outcomes.

    Science.gov (United States)

    Abougergi, Marwan S; Peluso, Heather; Saltzman, John R

    2018-03-28

    We aimed to determine the rate of hospital readmission within 30 days of non-variceal upper gastrointestinal hemorrhage and its impact on mortality, morbidity, and health care use in the United States. We performed a retrospective study using the Agency for Healthcare Research and Quality's Healthcare Cost and Utilization Project Nationwide Readmission Database for the year 2014 (data on 14.9 million hospital stays at 2048 hospitals in 22 states). We collected data on hospital readmissions of 203,220 adults who were hospitalized for urgent non-variceal upper gastrointestinal hemorrhage and discharged. The primary outcome was rate of all-cause readmission within 30 days of discharge. Secondary outcomes were reasons for readmission, readmission mortality rate, morbidity (shock and prolonged mechanical ventilation) and resource use (length of stay and total hospitalization costs and charges). Independent risk factors for readmission were identified using Cox regression analysis. The 30-day rate of readmission was 13%. Only 18% of readmissions were due to recurrent non-variceal upper gastrointestinal bleeding. The rate of death among patients readmitted to the hospital (4.7%) was higher than that for index admissions (1.9%) (P upper endoscopy, and prolonged mechanical ventilation were associated with lower odds for readmission. In a retrospective study of patients hospitalized for non-variceal upper gastrointestinal hemorrhage, 13% are readmitted to the hospital within 30 days of discharge. Readmission is associated with higher mortality, morbidity, and resource use. Most readmissions are not for recurrent gastrointestinal bleeding. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  17. Antifibrinolytic amino acids for upper gastrointestinal bleeding in people with acute or chronic liver disease.

    Science.gov (United States)

    Martí-Carvajal, Arturo J; Solà, Ivan

    2015-06-09

    Upper gastrointestinal bleeding is one of the most frequent causes of morbidity and mortality in the course of liver cirrhosis. People with liver disease frequently have haemostatic abnormalities such as hyperfibrinolysis. Therefore, antifibrinolytic amino acids have been proposed to be used as supplementary interventions alongside any of the primary treatments for upper gastrointestinal bleeding in people with liver diseases. This is an update of this Cochrane review. To assess the beneficial and harmful effects of antifibrinolytic amino acids for upper gastrointestinal bleeding in people with acute or chronic liver disease. We searched The Cochrane Hepato-Biliary Controlled Trials Register (February 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (Issue 2 of 12, 2015), MEDLINE (Ovid SP) (1946 to February 2015), EMBASE (Ovid SP) (1974 to February 2015), Science Citation Index EXPANDED (1900 to February 2015), LILACS (1982 to February 2015), World Health Organization Clinical Trials Search Portal (accessed 26 February 2015), and the metaRegister of Controlled Trials (accessed 26 February 2015). We scrutinised the reference lists of the retrieved publications. Randomised clinical trials irrespective of blinding, language, or publication status for assessment of benefits and harms. Observational studies for assessment of harms. We planned to summarise data from randomised clinical trials using standard Cochrane methodologies and assessed according to the GRADE approach. We found no randomised clinical trials assessing antifibrinolytic amino acids for treating upper gastrointestinal bleeding in people with acute or chronic liver disease. We did not identify quasi-randomised, historically controlled, or observational studies in which we could assess harms. This updated Cochrane review identified no randomised clinical trials assessing the benefits and harms of antifibrinolytic amino acids for upper gastrointestinal bleeding in people with acute or

  18. High energy X-ray observations of COS-B gamma-ray sources from OSO-8

    Science.gov (United States)

    Dolan, J. F.; Crannell, C. J.; Dennis, B. R.; Frost, K. J.; Orwig, L. E.; Caraveo, P. A.

    1985-01-01

    During the three years between satellite launch in June 1975 and turn-off in October 1978, the high energy X-ray spectrometer on board OSO-8 observed nearly all of the COS-B gamma-ray source positions given in the 2CG catalog (Swanenburg et al., 1981). An X-ray source was detected at energies above 20 keV at the 6-sigma level of significance in the gamma-ray error box containing 2CG342 - 02 and at the 3-sigma level of significance in the error boxes containing 2CG065 + 00, 2CG195 + 04, and 2CG311 - 01. No definite association between the X-ray and gamma-ray sources can be made from these data alone. Upper limits are given for the 2CG sources from which no X-ray flux was detected above 20 keV.

  19. Laparoscopic ultrasonography--a method for staging of upper gastrointestinal cancer

    DEFF Research Database (Denmark)

    Durup Scheel-Hincke, J; Mortensen, M B; Pless, T

    1999-01-01

    Laparoscopic ultrasonography (LUS) is a method that can be useful in the staging of upper gastrointestinal cancer. Dedicated transducers are available, and preliminary studies have proposed indications for the use of LUS staging of hepatic, esophageal, gastric, and pancreatic cancer disease. In t...

  20. Intensity of diffracted X-rays from biomolecules with radiation damage caused by strong X-ray pulses

    International Nuclear Information System (INIS)

    Kai, Takeshi; Tokuhisa, Atsushi; Moribayashi, Kengo; Fukuda, Yuji; Kono, Hidetoshi; Go, Nobuhiro

    2014-01-01

    In order to realize the coherent X-ray diffractive imaging of single biomolecules, the diffraction intensities, per effective pixel of a single biomolecule with radiation damage, caused by irradiation using a strong coherent X-ray pulse, were examined. A parameter survey was carried out for various experimental conditions, using a developed simulation program that considers the effect of electric field ionization, which was slightly reported on in previous studies. The two simple relationships among the parameters were identified as follows: (1) the diffraction intensity of a biomolecule slightly increases with the incident X-ray energy; and that (2) the diffraction intensity is approximately proportional to the target radius, when the radius is longer than 400 Å, since the upper limit of the incident intensity for damage to the biomolecules marginally changes with respect to the target radius. (author)

  1. Upper Gastrointestinal Tract Cancers at Endoscopy in Kano, North ...

    African Journals Online (AJOL)

    Cancer registration in Nigeria is poorly done, this is even so in North-Western Nigeria. It is only of recent that attempts are being made to know the profile of cancers seen in clinical practice in our environment. This study was done to establish the pattern of upper gastrointestinal cancers at Kano, North-Western Nigeria.

  2. Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine

    International Nuclear Information System (INIS)

    Cho, Jeong Yeon; Han, Won Jeong; Kim, Eun Kyung

    2007-01-01

    The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines

  3. Successful Endoscopic Hemostasis Is a Protective Factor for Rebleeding and Mortality in Patients with Nonvariceal Upper Gastrointestinal Bleeding.

    Science.gov (United States)

    Han, Yong Jae; Cha, Jae Myung; Park, Jae Hyun; Jeon, Jung Won; Shin, Hyun Phil; Joo, Kwang Ro; Lee, Joung Il

    2016-07-01

    Rebleeding and mortality rates remain high in patients with nonvariceal upper gastrointestinal bleeding. To identify clinical and endoscopic risk factors for rebleeding and mortality in patients with nonvariceal upper gastrointestinal bleeding. This study was performed in patients with nonvariceal upper gastrointestinal bleeding who underwent upper endoscopic procedures between July 2006 and February 2013. Clinical and endoscopic characteristics were compared among patients with and without rebleeding and mortality. Logistic regression analysis was performed to determine independent risk factors for rebleeding and mortality. After excluding 64 patients, data for 689 patients with nonvariceal upper gastrointestinal bleeding were analyzed. Peptic ulcer (62.6 %) was by far the most common source of bleeding. Endoscopic intervention was performed within 24 h in 99.0 % of patients, and successful endoscopic hemostasis was possible in 80.7 % of patients. The 30-day rebleeding rate was 13.1 % (n = 93). Unsuccessful endoscopic hemostasis was found to be the only independent risk factor for rebleeding (odds ratio 79.6; 95 % confidence interval 37.8-167.6; p = 0.000). The overall 30-day mortality rate was 3.2 % (n = 23). Unsuccessful endoscopic hemostasis (odds ratio 4.9; 95 % confidence interval 1.7-13.9; p = 0.003) was also associated with increased 30-day mortality in patients with nonvariceal upper gastrointestinal bleeding. Successful endoscopic hemostasis is an independent protective factor for both rebleeding and mortality in patients with nonvariceal upper gastrointestinal bleeding.

  4. Association of Proton Pump Inhibitors With Reduced Risk of Warfarin-Related Serious Upper Gastrointestinal Bleeding.

    Science.gov (United States)

    Ray, Wayne A; Chung, Cecilia P; Murray, Katherine T; Smalley, Walter E; Daugherty, James R; Dupont, William D; Stein, C Michael

    2016-12-01

    Proton pump inhibitors (PPIs) might reduce the risk of serious warfarin-related upper gastrointestinal bleeding, but the evidence of their efficacy for this indication is limited. A gastroprotective effect of PPIs would be particularly important for patients who take warfarin with antiplatelet drugs or nonselective nonsteroidal anti-inflammatory drugs (NSAIDs), which further increase the risk of gastrointestinal bleeding. This retrospective cohort study of patients beginning warfarin treatment in Tennessee Medicaid and the 5% National Medicare Sample identified 97,430 new episodes of warfarin treatment with 75,720 person-years of follow-up. The study end points were hospitalizations for upper gastrointestinal bleeding potentially preventable by PPIs and for bleeding at other sites. Patients who took warfarin without PPI co-therapy had 119 hospitalizations for upper gastrointestinal bleeding per 10,000 person-years of treatment. The risk decreased by 24% among patients who received PPI co-therapy (adjusted hazard ratio [HR], 0.76; 95% confidence interval [CI], 0.63-0.91). There was no significant reduction in the risk of other gastrointestinal bleeding hospitalizations (HR, 1.07; 95% CI, 0.94-1.22) or non-gastrointestinal bleeding hospitalizations (HR, 0.98; 95% CI, 0.84-1.15) in this group. Among patients concurrently using antiplatelet drugs or NSAIDs, those without PPI co-therapy had 284 upper gastrointestinal bleeding hospitalizations per 10,000 person-years of warfarin treatment. The risk decreased by 45% (HR, 0.55; 95% CI, 0.39-0.77) with PPI co-therapy. PPI co-therapy had no significant protective effect for warfarin patients not using antiplatelet drugs or NSAIDs (HR, 0.86; 95% CI, 0.70-1.06). Findings were similar in both study populations. In an analysis of patients beginning warfarin treatment in Tennessee Medicaid and the 5% National Medicare Sample, PPI co-therapy was associated with reduced risk of warfarin-related upper gastrointestinal bleeding; the

  5. Measurement of X-ray beam emittance using crystal optics at an X-ray undulator beamline

    International Nuclear Information System (INIS)

    Kohmura, Yoshiki; Suzuki, Yoshio; Awaji, Mitsuhiro; Tanaka, Takashi; Hara, Toru; Goto, Shunji; Ishikawa, Tetsuya

    2000-01-01

    We present a method of using crystal optics to measure the emittance of the X-ray source. Two perfect crystals set in (++) configuration work as a high-resolution collimator. The phase-space diagram (i.e. beam cross-section and angular distribution) could be determined without any assumptions on the light source. When the measurement is done at short wavelength radiation from undulator, the electron beam emittance is larger than the diffraction limit of the X-rays. Therefore, the electron beam emittance could be estimated. The measurement was done with the hard X-rays of 18.5 and 55 keV from an undulator beamline, BL 47XU, of SPring-8. The horizontal emittance of the X-ray beam was estimated to be about 7.6 nmrad, close to the designed electron beam emittance of the storage ring (7 nmrad). Some portions of the instrumental functions, such as the scattering by filters and windows along the beamline and the slight bent of the crystal planes of the monochromator, could not be precisely evaluated, but an upper limit for the vertical emittance of the electron beam could be obtained as 0.14 nmrad

  6. Profiling lifetime episodes of upper gastrointestinal bleeding among patients from rural Sub-Saharan Africa where schistosoma mansoni is endemic.

    Science.gov (United States)

    Opio, Christopher Kenneth; Kazibwe, Francis; Ocama, Ponsiano; Rejani, Lalitha; Belousova, Elena Nikolaevna; Ajal, Paul

    2016-01-01

    Severe chronic hepatic schistosomiasis is a common cause of episodes upper gastrointestinal bleeding (UGIB) in sub-Saharan Africa (SSA). However, there is paucity of data on clinical epidemiology of episodes of UGIB from rural Africa despite on going public health interventions to control and eliminate schistosomiasis. Through a cross sectional study we profiled lifetime episodes of upper gastrointestinal bleeding and associated factors at a rural primary health facility in sub-Saharan Africa were schistosomiasis is endemic. The main outcome was number of lifetime episodes of UGIB analyzed as count data. From 107 enrolled participants, 323 lifetime episodes of UGIB were reported. Fifty-seven percent experienced ≥ 2 lifetime episodes of UGIB. Ninety-four percent had severe chronic hepatic schistosomiasis and 80% esophageal varices. Alcohol use and viral hepatitis was infrequent. Eighty-eight percent were previously treated with praziquantel and 70% had a history of blood transfusion. No patient had ever had an endoscopy or treatment for prevention of recurrent variceal bleeding. Multivariable analysis identified a cluster of eight clinical factor variables (age ≥ 40, female sex, history of blood transfusion, abdominal collaterals, esophageal varices, pattern x periportal fibrosis, anemia, and thrombocytopenia) significantly associated (P-value Upper gastrointestinal bleeding is a common health problem in this part of rural SSA where schistosomiasis is endemic. The clinical profile described is unique and is important for improved case management, and for future research.

  7. [Epidemiology of upper gastrointestinal bleeding in Gabon].

    Science.gov (United States)

    Gaudong Mbethe, G L; Mounguengui, D; Ondounda, M; Magne, C; Bignoumbra, R; Ntsoumou, S; Moussavou Kombila, J-B; Nzenze, J R

    2014-01-01

    The department of internal medicine of the military hospital of Gabon managed 92 cases of upper gastrointestinal bleeding from April 2009 to November 2011. The frequency of these hemorrhages in the department was 8.2%; they occurred most often in adults aged 30-40 years and 50-60 years, and mainly men (74%). Erosive-ulcerative lesions (65.2%) were the leading causes of hemorrhage, followed by esophageal varices (15.2%). These results underline the importance of preventive measures for the control of this bleeding.

  8. The diagnosis and therapy of intractable upper gastrointestinal hemorrhage caused by hepatic arterioportal vein fistulas in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Luo Pengfei; Chen Xiaoming; Lu Ligong; Hu Baoshan; Li Yong

    2007-01-01

    Objective: To investigate the hemodynamics of increasing portal venous pressure(PVP) in hepatocellular carcinoma patients complicated with hepatic arterioportal vein fistulas (HAPVF) and the diagnosis and therapy of intractable upper gastrointestinal hemorrhage caused by HAPVF. Methods: One hundred and fifteen cases of hepatocellular carcinoma with upper gastrointestinal hemorrhage were checked by hepatic arteriography and were treated through orifices embolization in cases with severe HAPCF by coils and/or ethanol. Results: Twenty-six out of 31 patients suffering intractable upper gastrointestinal hemorrhage have severe HAPVF (the main stem of portal veins are visible). However, there are only 15 patients with light HAPVF among the 84 patients who have mild upper gastrointestinal hemorrhage (the main stem of portal veins are invisible). After the embolization, all of the 26 patients who have severe HAPVF stopped bleeding. Among them, the main stem of hepatic arteries are occluded in 2 patients. Conclusion: The existence of severe HAPVF should be taken into consideration when intractable upper gastrointestinal hemorrhage occurs in hepatocellular carcinoma patients, and it can be diagnosed through hepatic artery DSA. Orifice embolization is the most effective method for such kind of hemorrhage. (authors)

  9. Tritium analysis of divertor tiles used in JET ITER-like wall campaigns by means of β-ray induced x-ray spectrometry

    Science.gov (United States)

    Hatano, Y.; Yumizuru, K.; Koivuranta, S.; Likonen, J.; Hara, M.; Matsuyama, M.; Masuzaki, S.; Tokitani, M.; Asakura, N.; Isobe, K.; Hayashi, T.; Baron-Wiechec, A.; Widdowson, A.; contributors, JET

    2017-12-01

    Energy spectra of β-ray induced x-rays from divertor tiles used in ITER-like wall campaigns of the Joint European Torus were measured to examine tritium (T) penetration into tungsten (W) layers. The penetration depth of T evaluated from the intensity ratio of W(Lα) x-rays to W(Mα) x-rays showed clear correlation with poloidal position; the penetration depth at the upper divertor region reached several micrometers, while that at the lower divertor region was less than 500 nm. The deep penetration at the upper part was ascribed to the implantation of high energy T produced by DD fusion reactions. The poloidal distribution of total x-ray intensity indicated higher T retention in the inboard side than the outboard side of the divertor region.

  10. Use and effect of X-ray protective clothing

    International Nuclear Information System (INIS)

    Rothe, W.

    1976-01-01

    The use of X-ray protective clothing in direct handling the patient was studied in 76 X-ray departments. Mainly two types of lead rubber aprons are used, older ones with a lead equivalent of 0.2 mm and aprons according to TGL 200-1606 with a lead equivalent of 0.25 mm. Aprons are not yet worn in all surgical departments. Their replacement by protective skirts is to be refused. If at all, lead rubber gloves are only used in standardized fluoroscopic examinations, especially in examining the gastrointestinal tract. It is emphasized that only the protected fore-part is to be directed to the main radiation source, especially in seating or leaning forward positions. (author)

  11. Non-invasive investigation of the upper gastrointestinal tract using technetium - 99m

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, T V [Royal Infirmary, Edinburgh (UK)

    1979-01-01

    The use of technetium - 99m in the non-invasive investigation of the upper gastrointestinal tract is discussed with particular reference to the evolution of a method of assessing gastric function or gastric acid secretion non-invasively and to the applications of this method in the investigation of surgical patients with disease of the upper gastrointestinal tract. The assessment of maximal acid output and the insulin response is described and the use of the test in the diagnosis of pernicious anaemia, hypo- and hyperchlorhydric states, gastric cancer, hiatus hernia and Barrett's oesophagus, coeliac disease, Meckel's diverticulum, and abdominal aortic aneurism outlined. The use of chemicals labelled with this tracer in hepatobilary scanning is briefly described.

  12. Upper gastrointestinal tract injuries by intraoperative radiotherapy for pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tabata, I; Isawa, T; Satomi, T; Tazima, T [Tokyo Metropolitan Komagome Hospital (Japan)

    1981-08-01

    Twenty-one patients with unresectable carcinoma of the pancreas were treated by intraoperative irradiation with a large electron dose of 1500 - 3000 rads and upper gastrointestinal complications were encountered in five cases. All of those five cases were for carcinoma of the pancreatic head, and were seen for gastrointestinal tract injuries of the duodenum as follows, gastric ulcer in 2 cases, ulcer of the 1st duodenal portion in one case and ulcer with severe stenosis of the 2nd or 3rd duodenal portion in one case, respectively. Endoscopic features of these postirradiation gastrointestinal ulcers were characterized by deep, punched-out ulcers with grayish bases and sharp margins. Clinically these ulcers and stenosis were very difficult to treat, so by-pass operations were performed in two cases, resulting in prolonged survival.

  13. The Importance of Rockall Scoring System for Upper Gastrointestinal Bleeding in Long-Term Follow-Up.

    Science.gov (United States)

    Bozkurt, Mehmet Abdussamet; Peker, Kıvanç Derya; Unsal, Mustafa Gökhan; Yırgın, Hakan; Kahraman, İzzettin; Alış, Halil

    2017-06-01

    The aim of the study is to examine the importance of Rockall scoring system in long-term setting to estimate re-bleeding and mortality rate due to upper gastrointestinal bleeding. A total of 321 patients who had been treated for upper gastrointestinal bleeding were recruited to the study. Patients' demographic and clinical data, the amount of blood transfusion, endoscopy results, and Rockall scores were retrieved from patients' charts. The re-bleeding, morbidity, and mortality rates were noted after 3 years of follow-up with telephone. Re-bleeding rate was statistically significantly higher in Rockall 4 group compared to Rockall 0 group. Mortality rate was also statistically significantly higher in Rockall 4 group. Rockall risk scoring system is a valuable tool to predict re-bleeding and mortality rates for patients with upper gastrointestinal bleeding in long-term setting.

  14. Poor endoscopic findings in children with non variceal upper gastrointestinal bleeding: is biopsy necessary?

    OpenAIRE

    Giannakopoulos, A; Logothetis, A; Panayiotou, J; Van-Vliet, K; Orfanou, I; Roma-Giannikou, E

    2010-01-01

    Background: Gastrointestinal bleeding in infants and children is a potentially serious condition in the practice of general pediatrics that requires investigation. The objective of this study is to describe the endoscopic and histopathological findings in children with upper gastrointestinal (UGI) bleeding of non variceal origin.

  15. Meta-analysis: antibiotic prophylaxis for cirrhotic patients with upper gastrointestinal bleeding - an updated Cochrane review

    DEFF Research Database (Denmark)

    Chavez-Tapia, N C; Barrientos-Gutierrez, T; Tellez-Avila, F

    2011-01-01

    Antibiotic prophylaxis seems to decrease the incidence of bacterial infections in patients with cirrhosis and upper gastrointestinal bleeding and is considered standard of care. However, there is no updated information regarding the effects of this intervention.......Antibiotic prophylaxis seems to decrease the incidence of bacterial infections in patients with cirrhosis and upper gastrointestinal bleeding and is considered standard of care. However, there is no updated information regarding the effects of this intervention....

  16. Primary aortojejunal fistula: a rare cause for massive upper gastrointestinal bleeding.

    Science.gov (United States)

    Paulasir, Sylvester; Khorfan, Rhami; Harsant, Christina; Anderson, Harry Linne

    2017-04-26

    A 68-year-old man presented to the emergency department with haematemesis and shock. Upper endoscopy and selective angiography could not identify the source of bleeding. He underwent selective embolisation of the gastroduodenal artery. The patient then had a period of about 24 hours with relative haemodynamic stability before having another episode of massive upper gastrointestinal bleed. A second attempt to embolise the common hepatic artery and distal coeliac axis was unsuccessful. Hence, he was urgently taken to the operating room for exploratory laparotomy. The source of bleeding could not be identified in the operating room. The patient went into cardiac arrest and expired. Autopsy revealed a fistula between proximal jejunum and a previously unknown abdominal aortic aneurysm (AAA). We present an entity that has only been described a few times in the literature while highlighting the importance of having a broad differential with upper gastrointestinal bleeding, especially when the source is not clearly evident. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. C-reactive protein as a prognostic indicator for rebleeding in patients with nonvariceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Lee, Han Hee; Park, Jae Myung; Lee, Soon-Wook; Kang, Seung Hun; Lim, Chul-Hyun; Cho, Yu Kyung; Lee, Bo-In; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gyu

    2015-05-01

    In patients with acute nonvariceal upper gastrointestinal bleeding, rebleeding after an initial treatment is observed in 10-20% and is associated with mortality. To investigate whether the initial serum C-reactive protein level could predict the risk of rebleeding in patients with acute nonvariceal upper gastrointestinal bleeding. This was a retrospective study using prospectively collected data for upper gastrointestinal bleeding. Initial clinical characteristics, endoscopic features, and C-reactive protein levels were compared between those with and without 30-day rebleeding. A total of 453 patients were included (mean age, 62 years; male, 70.9%). The incidence of 30-day rebleeding was 15.9%. The mean serum C-reactive protein level was significantly higher in these patients than in those without rebleeding (Pupper gastrointestinal bleeding, indicating a possible role as a useful screening indicator for predicting the risk of rebleeding. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Diagnostic accuracy of indirect laryngoscopy and x-ray neck in the diagnosis of fish bone impaction in upper aero digestive tract

    International Nuclear Information System (INIS)

    Kundi, N.; Mehmood, T.

    2015-01-01

    This study was aimed at finding the validity of indirect laryngoscopy (IDL) and neck X-Rays in the diagnosis of fish bone impaction. Study Design: Validation study. Place and Duration of Study: CMH Nowshera from August 2012 to February 2013. Material and Methods: A total of 50 patients were selected by consecutive sampling presenting with history of fishbone impaction in aerodigestive tract. IDL examination and neck X-rays were performed and findings were recorded. Those with no fishbone on both the investigations were discharged from hospital with follow up after 03 days. Those with fishbone detected on either of investigations underwent removal. Fishbone easily approachable were removed under local anaesthesia with foreceps and in others Endoscopy (Direct laryngoscopy or Oesophagoscopy) was performed under General Anaesthesia. Sensitivities and specificities of both the modalities were calculated using standard 2/2 Table. ROC curve analysis was carried out and significance level p < 0.05 was taken as significant. Results: In 20 patients no fishbone was found, 26 patients were diagnosed on IDL and in 04 patients fishbone was detected by neck X-Rays. Most common site for fishbone impaction was pharyngeal tonsil. In 22 patients fishbone was removed with foreceps and in 08 patients endoscopy was performed. Diagnostic accuracy for IDL 86% and Neck X-Rays 48% was calculated. ROC curve analysis revealed AUC for IDL 0.933 and Significance level (P) as <0.0001. ROC curve analysis for X-ray gives AUC of 0.567 and Significance level (p) 0.4132. Conclusion: IDL shows higher diagnostic accuracy than neck X-Rays for detection of fishbone in upper aerodigestive tract. Neck X-rays are more useful for impacted foreign bodies in oesophagus. (author)

  19. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  20. Barium peritonitis following upper gastrointestinal series: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook [Soonchunhyang University College of Medicine, Seoul Hospital, Seoul (Korea, Republic of)

    2017-06-15

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly.

  1. Barium peritonitis following upper gastrointestinal series: A case report

    International Nuclear Information System (INIS)

    Ko, Su Jin; Hwang, Ji Young; Kim, Yong Jin; Hong, Seong Sook

    2017-01-01

    We report a rare case of barium peritonitis following an upper gastrointestinal (GI) series and its imaging findings in a 74-year-old female. Barium peritonitis is a rare but life-threatening complication of GI contrast investigation. Therefore, clinical awareness of barium peritonitis as a complication of GI tract contrast investigation would help to prevent such a complication and manage the patients properly

  2. Association between selective serotonin reuptake inhibitors and upper gastrointestinal bleeding: population based case-control study

    Science.gov (United States)

    de Abajo, Francisco José; Rodríguez, Luis Alberto García; Montero, Dolores

    1999-01-01

    Objective To examine the association between selective serotonin reuptake inhibitors and risk of upper gastrointestinal bleeding. Design Population based case-control study. Setting General practices included in the UK general practice research database. Subjects 1651 incident cases of upper gastrointestinal bleeding and 248 cases of ulcer perforation among patients aged 40 to 79 years between April 1993 and September 1997, and 10 000 controls matched for age, sex, and year that the case was identified. Interventions Review of computer profiles for all potential cases, and an internal validation study to confirm the accuracy of the diagnosis on the basis of the computerised information. Main outcome measures Current use of selective serotonin reuptake inhibitors or other antidepressants within 30 days before the index date. Results Current exposure to selective serotonin reuptake inhibitors was identified in 3.1% (52 of 1651) of patients with upper gastrointestinal bleeding but only 1.0% (95 of 10 000) of controls, giving an adjusted rate ratio of 3.0 (95% confidence interval 2.1 to 4.4). This effect measure was not modified by sex, age, dose, or treatment duration. A crude incidence of 1 case per 8000 prescriptions was estimated. A small association was found with non-selective serotonin reuptake inhibitors (relative risk 1.4, 1.1 to 1.9) but not with antidepressants lacking this inhibitory effect. None of the groups of antidepressants was associated with ulcer perforation. The concurrent use of selective serotonin reuptake inhibitors with non-steroidal anti-inflammatory drugs increased the risk of upper gastrointestinal bleeding beyond the sum of their independent effects (15.6, 6.6 to 36.6). A smaller interaction was also found between selective serotonin reuptake inhibitors and low dose aspirin (7.2, 3.1 to 17.1). Conclusions Selective serotonin reuptake inhibitors increase the risk of upper gastrointestinal bleeding. The absolute effect is, however

  3. Search for thermal X-ray features from the Crab nebula with the Hitomi soft X-ray spectrometer

    Science.gov (United States)

    Hitomi Collaboration; Aharonian, Felix; Akamatsu, Hiroki; Akimoto, Fumie; Allen, Steven W.; Angelini, Lorella; Audard, Marc; Awaki, Hisamitsu; Axelsson, Magnus; Bamba, Aya; Bautz, Marshall W.; Blandford, Roger; Brenneman, Laura W.; Brown, Gregory V.; Bulbul, Esra; Cackett, Edward M.; Chernyakova, Maria; Chiao, Meng P.; Coppi, Paolo S.; Costantini, Elisa; de Plaa, Jelle; de Vries, Cor P.; den Herder, Jan-Willem; Done, Chris; Dotani, Tadayasu; Ebisawa, Ken; Eckart, Megan E.; Enoto, Teruaki; Ezoe, Yuichiro; Fabian, Andrew C.; Ferrigno, Carlo; Foster, Adam R.; Fujimoto, Ryuichi; Fukazawa, Yasushi; Furuzawa, Akihiro; Galeazzi, Massimiliano; Gallo, Luigi C.; Gandhi, Poshak; Giustini, Margherita; Goldwurm, Andrea; Gu, Liyi; Guainazzi, Matteo; Haba, Yoshito; Hagino, Kouichi; Hamaguchi, Kenji; Harrus, Ilana M.; Hatsukade, Isamu; Hayashi, Katsuhiro; Hayashi, Takayuki; Hayashida, Kiyoshi; Hiraga, Junko S.; Hornschemeier, Ann; Hoshino, Akio; Hughes, John P.; Ichinohe, Yuto; Iizuka, Ryo; Inoue, Hajime; Inoue, Yoshiyuki; Ishida, Manabu; Ishikawa, Kumi; Ishisaki, Yoshitaka; Kaastra, Jelle; Kallman, Tim; Kamae, Tsuneyoshi; Kataoka, Jun; Katsuda, Satoru; Kawai, Nobuyuki; Kelley, Richard L.; Kilbourne, Caroline A.; Kitaguchi, Takao; Kitamoto, Shunji; Kitayama, Tetsu; Kohmura, Takayoshi; Kokubun, Motohide; Koyama, Katsuji; Koyama, Shu; Kretschmar, Peter; Krimm, Hans A.; Kubota, Aya; Kunieda, Hideyo; Laurent, Philippe; Lee, Shiu-Hang; Leutenegger, Maurice A.; Limousin, Olivier; Loewenstein, Michael; Long, Knox S.; Lumb, David; Madejski, Greg; Maeda, Yoshitomo; Maier, Daniel; Makishima, Kazuo; Markevitch, Maxim; Matsumoto, Hironori; Matsushita, Kyoko; McCammon, Dan; McNamara, Brian R.; Mehdipour, Missagh; Miller, Eric D.; Miller, Jon M.; Mineshige, Shin; Mitsuda, Kazuhisa; Mitsuishi, Ikuyuki; Miyazawa, Takuya; Mizuno, Tsunefumi; Mori, Hideyuki; Mori, Koji; Mukai, Koji; Murakami, Hiroshi; Mushotzky, Richard F.; Nakagawa, Takao; Nakajima, Hiroshi; Nakamori, Takeshi; Nakashima, Shinya; Nakazawa, Kazuhiro; Nobukawa, Kumiko K.; Nobukawa, Masayoshi; Noda, Hirofumi; Odaka, Hirokazu; Ohashi, Takaya; Ohno, Masanori; Okajima, Takashi; Ota, Naomi; Ozaki, Masanobu; Paerels, Frits; Paltani, Stéphane; Petre, Robert; Pinto, Ciro; Porter, Frederick S.; Pottschmidt, Katja; Reynolds, Christopher S.; Safi-Harb, Samar; Saito, Shinya; Sakai, Kazuhiro; Sasaki, Toru; Sato, Goro; Sato, Kosuke; Sato, Rie; Sato, Toshiki; Sawada, Makoto; Schartel, Norbert; Serlemtsos, Peter J.; Seta, Hiromi; Shidatsu, Megumi; Simionescu, Aurora; Smith, Randall K.; Soong, Yang; Stawarz, Łukasz; Sugawara, Yasuharu; Sugita, Satoshi; Szymkowiak, Andrew; Tajima, Hiroyasu; Takahashi, Hiromitsu; Takahashi, Tadayuki; Takeda, Shin'ichiro; Takei, Yoh; Tamagawa, Toru; Tamura, Takayuki; Tanaka, Takaaki; Tanaka, Yasuo; Tanaka, Yasuyuki T.; Tashiro, Makoto S.; Tawara, Yuzuru; Terada, Yukikatsu; Terashima, Yuichi; Tombesi, Francesco; Tomida, Hiroshi; Tsuboi, Yohko; Tsujimoto, Masahiro; Tsunemi, Hiroshi; Tsuru, Takeshi Go; Uchida, Hiroyuki; Uchiyama, Hideki; Uchiyama, Yasunobu; Ueda, Shutaro; Ueda, Yoshihiro; Uno, Shin'ichiro; Urry, C. Megan; Ursino, Eugenio; Watanabe, Shin; Werner, Norbert; Wilkins, Dan R.; Williams, Brian J.; Yamada, Shinya; Yamaguchi, Hiroya; Yamaoka, Kazutaka; Yamasaki, Noriko Y.; Yamauchi, Makoto; Yamauchi, Shigeo; Yaqoob, Tahir; Yatsu, Yoichi; Yonetoku, Daisuke; Zhuravleva, Irina; Zoghbi, Abderahmen; Tominaga, Nozomu; Moriya, Takashi J.

    2018-03-01

    The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 AD. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core-collapse SN. Intensive searches have been made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that SN 1054 is an electron-capture (EC) explosion with a lower explosion energy by an order of magnitude than Fe-core-collapse SNe. X-ray imaging searches were performed for the plasma emission from the shell in the Crab outskirts to set a stringent upper limit on the X-ray emitting mass. However, the extreme brightness of the source hampers access to its vicinity. We thus employed spectroscopic technique using the X-ray micro-calorimeter on board the Hitomi satellite. By exploiting its superb energy resolution, we set an upper limit for emission or absorption features from as yet undetected thermal plasma in the 2-12 keV range. We also re-evaluated the existing Chandra and XMM-Newton data. By assembling these results, a new upper limit was obtained for the X-ray plasma mass of ≲ 1 M⊙ for a wide range of assumed shell radius, size, and plasma temperature values both in and out of collisional equilibrium. To compare with the observation, we further performed hydrodynamic simulations of the Crab SNR for two SN models (Fe-core versus EC) under two SN environments (uniform interstellar medium versus progenitor wind). We found that the observed mass limit can be compatible with both SN models if the SN environment has a low density of ≲ 0.03 cm-3 (Fe core) or ≲ 0.1 cm-3 (EC) for the uniform density, or a progenitor wind density somewhat less than that provided by a mass loss rate of 10-5 M⊙ yr-1 at 20 km s-1 for the wind environment.

  4. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  5. 'Horses for courses' in the upper gastrointestinal tract: a rational approach to diagnosis

    International Nuclear Information System (INIS)

    Mendelson, R.M.

    1989-01-01

    In Australia, the number of barium studies performed in teaching hospitals has fallen markedly while in the community at large a 113% increase occurred in the number of upper gastrointestinal endoscopic procedures performed between 1980 and 1986. Protagonists of primary endoscopy cite studies that report on the superiority of oesophagogastroduodenoscopy in patients with dyspepsia and related symptoms but several studies have shown that upper gastrointestinal barium studies miss very few important lesions. Fibreoptic endoscopy and radiology each have strengths and weaknesses which determine their respective places in the investigation of the different symptom complexes that are referable to the upper gastrointestinal tract. Double-contrast barium-meal examination is the suggested imaging modality for simple dyspepsia, for the oesophagitis-reflux-hiatus hernia complex and for dysphagia; while oesophagogastroduodenoscopy is the method of choice for the investigation of complicated dyspepsia, haematemesis and melaena. In patients who have previously undergone gastric surgery, endoscopy and radiology are complementary procedures - the former more accurate in the diagnosis of recurrent disease like ulceration, and the later useful for the delineation of anatomical changes. The time for the across-the-board replacement of barium studies by primary endoscopy has not yet arrived. 57 refs

  6. Glossopharyngeal Nerve Block versus Lidocaine Spray to Improve Tolerance in Upper Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Moisés Ortega Ramírez

    2013-01-01

    Full Text Available Aim of the Study. To compare the effect of glossopharyngeal nerve block with topical anesthesia on the tolerance of patients to upper gastrointestinal endoscopy. Methods. We performed a clinical trial in one hundred patients undergoing upper gastrointestinal endoscopy. Subjects were randomly assigned to one of the following two groups: (1 treatment with bilateral glossopharyngeal nerve block (GFNB and intravenous midazolam or (2 treatment with topical anesthetic (TASS and intravenous midazolam. We evaluated sedation, tolerance to the procedure, hemodynamic stability, and adverse symptoms. Results. We studied 46 men and 54 women, from 17 to 78 years of age. The procedure was reported without discomfort in 48 patients (88% in the GFNB group and 32 (64% in the TAAS group; 6 patients (12% in GFNB group and 18 (36% in TAAS group reported the procedure as little discomfort (χ2=3.95, P=0.04. There was no difference in frequency of nausea (4% in both groups and retching, 4% versus 8% for GFNB and TASS group, respectively (P=0.55. Conclusions. The use of glossopharyngeal nerve block provides greater comfort and tolerance to the patient undergoing upper gastrointestinal endoscopy. It also reduces the need for sedation.

  7. Response of the upper atmosphere to variations in the solar soft x-ray irradiance. Ph.D. Thesis

    Science.gov (United States)

    Bailey, Scott Martin

    1995-01-01

    Terrestrial far ultraviolet (FUV) airglow emissions have been suggested as a means for remote sensing the structure of the upper atmosphere. The energy which leads to the excitation of FUV airglow emissions is solar irradiance at extreme ultraviolet (EUV) and soft x-ray wavelengths. Solar irradiance at these wavelengths is known to be highly variable; studies of nitric oxide (NO) in the lower thermosphere have suggested a variability of more than an order of magnitude in the solar soft x-ray irradiance. To properly interpret the FUV airflow, the magnitude of the solar energy deposition must be known. Previous analyses have used the electron impact excited Lyman-Birge-Hopfield (LBH) bands of N2 to infer the flux of photoelectrons in the atmosphere and thus to infer the magnitude of the solar irradiance. This dissertation presents the first simultaneous measurements of the FUV airglow, the major atmospheric constituent densities, and the solar EUV and soft x-ray irradiances. The measurements were made on three flights of an identical sounding rocket payload at different levels of solar activity. The linear response in brightness of the LBH bands to variations in solar irradiance is demonstrated. In addition to the N2 LBH bands, atomic oxygen lines at 135.6 and 130.4 nm are also studied. Unlike the LBH bands, these emissions undergo radiative transfer effects in the atmosphere. The OI emission at 135.6 nm is found to be well modeled using a radiative transfer calculation and the known excitation processes. Unfortunately, the assumed processes leading to OI 130.4 nm excitation are found to be insufficient to reproduce the observed variability of this emission. Production of NO in the atmosphere is examined; it is shown that a lower than previously reported variability in the solar soft x-ray irradiance is required to explain the variability of NO.

  8. National variation in transfusion strategies in patients with upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Steinthorsdottir, Kristin Julia; Svenningsen, Peter Olsen; Fabricius, Rasmus

    2016-01-01

    INTRODUCTION: An optimal transfusion strategy for patients with upper gastrointestinal bleeding (UGIB) has yet to be established. The national guidelines contain recommendations for patients with life-threating bleeding in general, but no specific recommendations for patients with UGIB. We...

  9. X-ray study of bow shocks in runaway stars

    Science.gov (United States)

    De Becker, M.; del Valle, M. V.; Romero, G. E.; Peri, C. S.; Benaglia, P.

    2017-11-01

    Massive runaway stars produce bow shocks through the interaction of their winds with the interstellar medium, with the prospect for particle acceleration by the shocks. These objects are consequently candidates for non-thermal emission. Our aim is to investigate the X-ray emission from these sources. We observed with XMM-Newton a sample of five bow shock runaways, which constitutes a significant improvement of the sample of bow shock runaways studied in X-rays so far. A careful analysis of the data did not reveal any X-ray emission related to the bow shocks. However, X-ray emission from the stars is detected, in agreement with the expected thermal emission from stellar winds. On the basis of background measurements we derive conservative upper limits between 0.3 and 10 keV on the bow shocks emission. Using a simple radiation model, these limits together with radio upper limits allow us to constrain some of the main physical quantities involved in the non-thermal emission processes, such as the magnetic field strength and the amount of incident infrared photons. The reasons likely responsible for the non-detection of non-thermal radiation are discussed. Finally, using energy budget arguments, we investigate the detectability of inverse Compton X-rays in a more extended sample of catalogued runaway star bow shocks. From our analysis we conclude that a clear identification of non-thermal X-rays from massive runaway bow shocks requires one order of magnitude (or higher) sensitivity improvement with respect to present observatories.

  10. Upper gastrointestinal endoscopy for dyspepsia: Εxploratory study of factors influencing patient compliance in Greece

    Directory of Open Access Journals (Sweden)

    Kouroumalis Elias

    2011-02-01

    Full Text Available Abstract Background Upper gastrointestinal endoscopy is the most preferable diagnostic examination for patients over fifty when upper gastrointestinal symptoms appear. However, limited knowledge exists in concerns to the compliance of primary care patients' to the doctors' recommendations for endoscopy. Methods Patients who visited primary care practices in Greece and experienced upper gastrointestinal symptoms within a 10 days screening study, were referred for an upper endoscopy exam. The patients which refused to complete the endoscopy exam, were interviewed by the use of an open- ended translated and validated questionnaire, the Identification of Dyspepsia in General Population (IDGP questionnaire. A qualitative thematic analysis grounded on the theory of planned behavior was performed to reveal the reasons for patients' refusal, while socio-demographic predictors were also assessed. Results Nine hundred and ninety two patients were recorded, 159 of them (16% were found positive for dyspepsia and gastro-esophageal reflux disease according to the IDGP questionnaire. Out of the above, 131 (83.6% patients refused further investigation with endoscopy. Patients who refused upper endoscopy were predominantly female (87.8% (p = 0.036 and over the age of 50. The lack of severe symptoms, fear of pain, concerns of sedation, comorbidity and competing life demands were reported by patients as barriers to performing an endoscopic investigation. Conclusions Patients with dyspepsia in rural Greece tend to avoid upper gastrointestinal endoscopy, with two major axons considered to be the causes of patients' refusal: their beliefs towards endoscopy and their personal capability to cope with it. Future research examining reasons of low compliance should be carried out in combination with modern behavioral theories so as to investigate into the above.

  11. The burden of upper gastrointestinal endoscopy in patients with Barrett's esophagus

    NARCIS (Netherlands)

    Kruijshaar, M. E.; Kerkhof, M.; Siersema, P. D.; Steyerberg, E. W.; Homs, M. Y. V.; Essink-Bot, M.-L.

    2006-01-01

    BACKGROUND AND STUDY AIMS: Patients with Barrett's esophagus are recommended to undergo regular surveillance with upper gastrointestinal endoscopy, an invasive procedure that may cause anxiety, pain, and discomfort. We assessed to what extent patients perceived this procedure as burdensome. PATIENTS

  12. Investigation of the gastrointestinal tract by means of the first dimerous nonionic x-ray contrast medium (Iotrolan)

    International Nuclear Information System (INIS)

    Troger, J.; Wenzel-Hora, B.I.

    1987-01-01

    The risks with an ionic, water solvent highly osmotic contrast medium (CM) have now led to a monomerous, nonionic CM being used, particularly in the field of gastrointestinal investigation in newborn babies and infants. Thus side effects could be reduced and the quality of the x-rays improved. However, since the monomerous nonionic CM is still hyperosmotic with respect to blood, there is a water shift into the intestinal lumen. This can upset hydration and impair the quality of radiographs. Iotrolan is the first CM isoosmotic to the blood to be used clinically. It has proved to be superior to a monomerous nonionic CM as far as radiographic quality (density and sharpness) is concerned. Fifty-one children, aged 2 days to 19 years, were give Iotrolan. Some of these patients were compared in a double-blind study with a group of children who had been given monomerous nonionic CM. If Iotrolan was given, the good quality of the radiographs remained constant throughout the gastrointestinal tract and details were clearly discernible, even in the rectum. In addition, Iotrolan in the aboral intestinal sections leads to double-contrast pictures and thereby further increases the identifiability of details. The monomerous nonionic CM, however, showed a loss in density and above all in sharpness during its passage. Since Iotrolan is isotonic to blood, its is superior to all other water-solvent CM as far as possible side effects and radiographic quality are concerned

  13. Burden of upper gastrointestinal symptoms in patients receiving low-dose acetylsalicylic acid for cardiovascular risk management

    DEFF Research Database (Denmark)

    Bytzer, Peter; Pratt, Stephen; Elkin, Eric

    2013-01-01

    Continuous low-dose acetylsalicylic acid (aspirin; ASA) is a mainstay of cardiovascular (CV) risk management. It is well established, however, that troublesome upper gastrointestinal (GI) symptoms are commonly experienced among low-dose ASA users.......Continuous low-dose acetylsalicylic acid (aspirin; ASA) is a mainstay of cardiovascular (CV) risk management. It is well established, however, that troublesome upper gastrointestinal (GI) symptoms are commonly experienced among low-dose ASA users....

  14. Acute upper gastrointestinal bleeding (UGIB) - initial evaluation and management.

    Science.gov (United States)

    Khamaysi, Iyad; Gralnek, Ian M

    2013-10-01

    Acute upper gastrointestinal bleeding (UGIB) is the most common reason that the 'on-call' gastroenterologist is consulted. Despite the diagnostic and therapeutic capabilities of upper endoscopy, there is still significant associated morbidity and mortality in patients experiencing acute UGIB, thus this is a true GI emergency. Acute UGIB is divided into non-variceal and variceal causes. The most common type of acute UGIB is 'non-variceal' and includes diagnoses such as peptic ulcer (gastric and duodenal), gastroduodenal erosions, Mallory-Weiss tears, erosive oesophagitis, arterio-venous malformations, Dieulafoy's lesion, and upper GI tract tumours and malignancies. This article focuses exclusively on initial management strategies for acute upper GI bleeding. We discuss up to date and evidence-based strategies for patient risk stratification, initial patient management prior to endoscopy, potential causes of UGIB, role of proton pump inhibitors, prokinetic agents, prophylactic antibiotics, vasoactive pharmacotherapies, and timing of endoscopy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Oncolytic virotherapy in upper gastrointestinal tract cancers

    Directory of Open Access Journals (Sweden)

    Yokoda R

    2018-03-01

    Full Text Available Raquel Yokoda,1 Bolni M Nagalo,1 Mansi Arora,1 Jan B Egan,1 James M Bogenberger,1 Thomas T DeLeon,1 Yumei Zhou,1 Daniel H Ahn,1 Mitesh J Borad1–3 1Division of Hematology/Oncology, Department of Medicine, Mayo Clinic, Scottsdale, AZ, 2Department of Molecular Medicine, Center for Individualized Medicine, Mayo Clinic, Rochester, MN, 3Department of Oncology, Mayo Clinic Cancer Center, Phoenix, AZ, USA Abstract: Upper gastrointestinal tract malignancies are among the most challenging cancers with regard to response to treatment and prognosis. Cancers of the esophagus, stomach, pancreas, liver, and biliary tree have dismal 5-year survival, and very modest improvements in this rate have been made in recent times. Oncolytic viruses are being developed to address these malignancies, with a focus on high safety profiles and low off-target toxicities. Each viral platform has evolved to enhance oncolytic potency and the clinical response to either single-agent viral therapy or combined viral treatment with radiotherapy and chemotherapy. A panel of genomic alterations, chimeric proteins, and pseudotyped capsids are the breakthroughs for vector success. This article revisits developments for each viral platform to each tumor type, in an attempt to achieve maximum tumor selectivity. From the bench to clinical trials, the scope of this review is to highlight the beginnings of translational oncolytic virotherapy research in upper gastrointestinal tract malignancies and provide a bioengineering perspective of the most promising platforms. Keywords: oncolytic viruses, hepatopancreatobiliary, gastric cancer, pancreatic cancer, liver cancer, biliary cancer

  16. Predicting the Occurrence of Hypotension in Stable Patients With Nonvariceal Upper Gastrointestinal Bleeding: Point-of-Care Lactate Testing.

    Science.gov (United States)

    Ko, Byuk Sung; Kim, Won Young; Ryoo, Seung Mok; Ahn, Shin; Sohn, Chang Hwan; Seo, Dong Woo; Lee, Yoon-Seon; Lim, Kyoung Soo; Jung, Hwoon-Yong

    2015-11-01

    It is difficult to assess risk in normotensive patients with upper gastrointestinal bleeding. The aim of this study was to evaluate whether the initial lactate value can predict the in-hospital occurrence of hypotension in stable patients with acute nonvariceal upper gastrointestinal bleeding. Retrospective, observational, single-center study. Emergency department of a tertiary-care, university-affiliated hospital during a 5-year period. Medical records of 3,489 patients with acute upper gastrointestinal bleeding who were normotensive at presentation to the emergency department. We analyzed the ability of point-of-care testing of lactate at emergency department admission to predict hypotension development (defined as systolic blood pressure upper gastrointestinal bleeding, 157 patients experienced hypotension within 24 hours. Lactate was independently associated with hypotension development (odds ratio, 1.6; 95% CI, 1.4-1.7), and the risk of hypotension significantly increased as the lactate increased from 2.5-4.9 mmol/L (odds ratio, 2.2) to 5.0-7.4 mmol/L (odds ratio, 4.0) and to greater than or equal to 7.5 mmol/L (odds ratio, 39.2) (pupper gastrointestinal bleeding. However, subsequently, prospective validate research will be required to clarify this.

  17. Linear luminescence for thin plastic scintillator under intense soft X-ray irradiation

    International Nuclear Information System (INIS)

    Ning Jiamin; Jiang Shilun; Xu Rongkun; Guo Cun

    2006-01-01

    The basic principle of soft X-ray power meter is introduced in the paper and the experimental process and the result of thin plastic scintillator linear luminescence under intense soft X-ray irradiation are described. A range of flux density of energy for thin plastic scintillator linear luminescence under intense soft X-ray irradiation is included. The upper limit of the flux density is 1.47 x 10 5 W/cm 2 . (authors)

  18. Reductions in 28-Day Mortality Following Hospital Admission for Upper Gastrointestinal Hemorrhage

    Science.gov (United States)

    Crooks, Colin; Card, Tim; West, Joe

    2011-01-01

    Background & Aims It is unclear whether mortality from upper gastrointestinal hemorrhage is changing: any differences observed might result from changes in age or comorbidity of patient populations. We estimated trends in 28-day mortality in England following hospital admission for gastrointestinal hemorrhage. Methods We used a case-control study design to analyze data from all adults administered to a National Health Service hospital, for upper gastrointestinal hemorrhage, from 1999 to 2007 (n = 516,153). Cases were deaths within 28 days of admission (n = 74,992), and controls were survivors to 28 days. The 28-day mortality was derived from the linked national death register. A logistic regression model was used to adjust trends in nonvariceal and variceal hemorrhage mortality for age, sex, and comorbidities and to investigate potential interactions. Results During the study period, the unadjusted, overall, 28-day mortality following nonvariceal hemorrhage was reduced from 14.7% to 13.1% (unadjusted odds ratio, 0.87; 95% confidence interval: 0.84–0.90). The mortality following variceal hemorrhage was reduced from 24.6% to 20.9% (unadjusted odds ratio, 0.8; 95% confidence interval: 0.69–0.95). Adjustments for age and comorbidity partly accounted for the observed trends in mortality. Different mortality trends were identified for different age groups following nonvariceal hemorrhage. Conclusions The 28-day mortality in England following both nonvariceal and variceal upper gastrointestinal hemorrhage decreased from 1999 to 2007, and the reduction had been partly obscured by changes in patient age and comorbidities. Our findings indicate that the overall management of bleeding has improved within the first 4 weeks of admission. PMID:21447331

  19. Effect of Transfusion Strategy in Acute Non-variceal Upper Gastrointestinal Bleeding

    DEFF Research Database (Denmark)

    Fabricius, Rasmus; Svenningsen, Peter; Hillingsø, Jens

    2016-01-01

    BACKGROUND: Acute non-variceal upper gastrointestinal bleeding (NVUGIB) is a common cause of admissions as well as aggressive transfusion of blood products. Whether the transfusion strategy in NVUGIB impacts on hemostasis is unknown and constitutes the focus of this study. METHOD: Retrospective...

  20. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  1. Analysis of the curative effect of interventional devascularization in hepatic cirrhosis, portal hypertension combined with upper gastrointestinal hemorrhage

    International Nuclear Information System (INIS)

    Wei Dingtai; Huang Hui; Huang Xiaomin; Lin Shifeng; Xin Yongtong; Ye Jian'an; Chen Youying

    2010-01-01

    Objective: To evaluate the curative effect of interventional embolization of gastroesophageal and splenic veins in patients with upper gastrointestinal hemorrhage from liver cirrhosis and portal hypertension. Methods: 11 patients with portal hypertension accompanying gastroesophageal variceal hemorrhage were treated with interventional devasculatization. The portal vein pressure, portal vein diameter and platelet before and after treatment as well as the therapeutic effect were evaluated. Results: The technical success rate and the rate of hemostasis were 100%. The portal vein pressure was (37.24±4.02), (40.38±4.15) and (26.33±4.14)cm H 2 O, respectively before and after the gastroesophageal variceal embolization (P=0.088) and after partial splenic vein embolization (P 9 /L, (173.64±55.47) x 10 9 /L (P<0.001), respectively,before and 2 weeks after interventional devascularization. Conclusion: Interventional devascularization can control bleeding immediately, decrease the portal vein pressure, and improve the peri-vascular platelets. It is safe and efficient in treating patients with upper gastrointestinal hemorrhage from liver cirrhosis and portal hypertension. (authors)

  2. Associated factors of atrophic gastritis diagnosed by double-contrast upper gastrointestinal barium X-ray radiography: a cross-sectional study analyzing 6,901 healthy subjects in Japan.

    Directory of Open Access Journals (Sweden)

    Nobutake Yamamichi

    Full Text Available Double-contrast upper gastrointestinal barium X-ray radiography (UGI-XR is one of the most widely conducted gastric cancer screening methods. It has been executed to find gastric cancer, but has not been usually executed to detect premalignant atrophic mucosa of stomach. To understand the meaning of UGI-XR-based atrophic gastritis, we analyzed its association with several causative factors including Helicobacter pylori (HP infection.We evaluated 6,901 healthy adults in Japan. UGI-XR-based atrophic gastritis was diagnosed based on the irregular shape of areae gastricae and its expansion in the stomach.Of the 6,433 subjects with no history of HP eradication and free from gastric acid suppressants, 1,936 were diagnosed as UGI-XR-based atrophic gastritis (mild: 234, moderate: 822, severe: 880. These were univariately associated with serum HP IgG and serum pepsinogen I/II ratio with statistical significance. The multiple logistic analysis calculating standardized coefficients (β and odds ratio (OR demonstrated that serum HP IgG (β = 1.499, OR = 4.48, current smoking (β = 0.526, OR = 1.69, age (β = 0.401, OR = 1.49, low serum pepsinogen I/II ratio (β = 0.339, OR = 1.40, and male gender (β = 0.306, OR = 1.36 showed significant positive association with UGI-XR-based atrophic gastritis whereas drinking and body mass index did not. Among the age/sex/smoking/drinking-matched 227 pairs derived from chronically HP-infected and successfully HP-eradicated subjects, UGI-XR-based atrophic gastritis was detected in 99.1% of the former but in only 59.5% of the latter subjects (p<0.0001. Contrastively, UGI-XR-based atrophic gastritis was detected in 13 of 14 HP-positive proton pump inhibitor users (92.9% and 33 of 34 HP-positive histamine H2-receptor antagonist users (97.1%, which are not significantly different from gastric acid suppressant-free subjects.The presence of UGI-XR-based atrophic gastritis is positively

  3. Clinical findings confirm national guidelines regarding primary gastroscopy for upper gastrointestinal symptoms

    DEFF Research Database (Denmark)

    Rolff, Hans Christian; Simonsen, Louise Rolighed; Rosenberg, Jacob

    2011-01-01

    This study describes unsedated transnasal oesophagogastroduodenoscopy (UT-OGD) in the office setting. Evaluation of national guidelines regarding primary endoscopy for the investigation of upper gastrointestinal (GI) symptoms was also a focus of this study....

  4. Tumor budding in upper gastrointestinal carcinomas

    Directory of Open Access Journals (Sweden)

    Viktor Hendrik Koelzer

    2014-08-01

    Full Text Available The basis of personalized medicine in oncology is the prediction of an individual’s risk of relapse and death from disease. The presence of tumor budding (TB at the tumor-host interface of gastrointestinal cancers has been recognized as a hallmark of unfavorable disease biology. TB is defined as the presence of dedifferentiated cells or small clusters of up to five cells at the tumor invasive front and can be observed in aggressive carcinomas of the esophagus, stomach, pancreas, ampulla, colon and rectum. Presence of TB reproducibly correlates with advanced tumor stage, frequent lymphovascular invasion, nodal and distant metastasis. The UICC has officially recognized TB as additional independent prognostic factor in cancers of the colon and rectum. Recent studies have also characterized TB as a promising prognostic indicator for clinical management of esophageal squamous cell carcinoma, adenocarcinoma of the gastro-esophageal junction and gastric adenocarcinoma. However, several important issues have to be addressed for application in daily diagnostic practice: 1 Validation of prognostic scoring systems for tumor budding in large, multi-center studies 2 Consensus on the optimal assessment method 3 Inter-observer reproducibility. This review provides a comprehensive analysis of TB in cancers of the upper gastrointestinal tract including critical appraisal of perspectives for further study.

  5. Expression, purification, crystallization and preliminary X-ray analysis of an NAD-dependent glyceraldehyde-3-phosphate dehydrogenase from Helicobacter pylori

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, Paul R.; Mohammad, Shabaz; Melrose, Helen J.; Moody, Peter C. E., E-mail: pcem1@leicester.ac.uk [Henry Wellcome Laboratories for Structural Biology, University of Leicester, Leicester LE1 9HN (United Kingdom)

    2008-08-01

    Glyceraldehyde-3-phosphate dehydrogenase B from H. pylori has been cloned, expressed, purified and crystallized in the presence of NAD. Crystals of GAPDHB diffracted to 2.8 Å resolution and belonged to space group P6{sub 5}22, with unit-cell parameters a = b = 166.1, c = 253.1 Å. Helicobacter pylori is a dangerous human pathogen that resides in the upper gastrointestinal tract. Little is known about its metabolism and with the onset of antibiotic resistance new treatments are required. In this study, the expression, purification, crystallization and preliminary X-ray diffraction of an NAD-dependent glyceraldehyde-3-phosphate dehydrogenase from H. pylori are reported.

  6. New X-ray bound on density of primordial black holes

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Yoshiyuki [Institute of Space and Astronautical Science JAXA, 3-1-1 Yoshinodai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan); Kusenko, Alexander, E-mail: yinoue@astro.isas.jaxa.jp, E-mail: kusenko@ucla.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095-1547 (United States)

    2017-10-01

    We set a new upper limit on the abundance of primordial black holes (PBH) based on existing X-ray data. PBH interactions with interstellar medium should result in significant fluxes of X-ray photons, which would contribute to the observed number density of compact X-ray objects in galaxies. The data constrain PBH number density in the mass range from a few M {sub ⊙} to 2× 10{sup 7} M {sub ⊙}. PBH density needed to account for the origin of black holes detected by LIGO is marginally allowed.

  7. Oligometastatic Disease in Upper Gastrointestinal Cancer – How to Proceed?

    Science.gov (United States)

    Chiapponi, Costanza; Berlth, Felix; Plum, Patrick S.; Betzler, Christopher; Stippel, Dirk L.; Popp, Felix; Bruns, Christiane J.

    2017-01-01

    Background In the present study we review and discuss the current evidence and suggest how to proceed in the management of oligometastatic disease in upper gastrointestinal cancer. Methods An electronic search of the PubMed database for relevant articles was performed. Results Both the search for ‘oligometastasis', ‘oligometastases', ‘oligometastatic’, ‘oligometastatic disease’ as well as ‘esophageal’ and ‘esophageal cancer’ and the search for ‘oligometastasis', ‘oligometastases', ‘oligometastatic’, ‘oligometastatic disease’ as well as ‘gastric’, ‘gastric cancer’, ‘stomach’, and ‘stomach cancer’ yielded very few studies. Most data need to be extrapolated in general studies on oligometastatic diseases of different origins. No randomized controlled trial could be found. Conclusion In the absence of data to formulate recommendations on how to proceed in the treatment of oligometastatic disease in upper gastrointestinal cancer, a more aggressive treatment of oligometastatic disease can be considered in patients whose tumors show a more favorable neoplastic behavior after the ‘test of time’. The RENAISSANCE study will certainly deliver important data regarding this aspect. PMID:28612014

  8. The Results of Upper Gastrointestinal Endoscopy Performed in Bayburt Province

    Directory of Open Access Journals (Sweden)

    Yavuz Ayar

    2013-09-01

    Full Text Available Aim: We analyzed the results of upper gastrointestinal endoscopy performed between November 2011 and January 2013 in the endoscopy unit at Bayburt State Hospital. Methods: Endoscopic analyses were done with a PENTAX EPK 100P equipment. The results were assessed retrospectively. Results: A total of 1008 patients (664 women, 344 men aged between 17 and 88 (mean: 50±18 years have undergone upper gastrointestinal endoscopy. 186 (18.4% patients were diagnosed with pangastritis, 81 - with esophagitis (8%, 68 - with antral gastritis (6.7%, 67 - with duodenal ulcer (6.6%, 57 - with gastric ulcer (5.6%, 35 - with alkaline reflux gastritis (3.6%, 21 - with duodenitis (2.1%, 5 - with gastric cancer (0.5%, 4 - with esophagial cancer (0.4%, 4 - with gastric polyp (0.4% and 3 patients were diagnosed with esophagial ulcer (0.3%. Conclusion: Lesions were most commonly observed in the stomach. Gastritis, esophagitis, duodenal and gastric ulcer were frequently observed in our city. (The Medical Bulletin of Haseki 2013; 51: 116-9

  9. Upper functional gastrointestinal disorders in young adults.

    Science.gov (United States)

    Adibi, Peyman; Behzad, Ebrahim; Shafieeyan, Mohammad; Toghiani, Ali

    2012-01-01

    Functional Gastrointestinal disorders (FGID) are common disorders in gastroenterology which are common in young adults. The aim of this study is evaluating the prevalence of upper FGID in iranian young adults. This was a cross-sectional study which was on 995 persons who were going to marry. A ROME III based questionnaire was used to determine the frequency of upper GI Syndromes among the sample population. Our results determined 74 subjects had functional dyspepsia (36 subjects diagnosed as postprandial distress syndrome patient and Epigastric pain syndrome was seen in 38 subjects). Functional heartburn was diagnosed in 52 participants. Globus was seen in 35 subjects and 41 had unspecified excessive belching. Many epidemiologic studies were done all around the world but there are different reports about prevalence and incidence of FGIDs. Our results were agreed with reported prevalence of FGIDs in Iran in adults. And our findings were agreed with some other Asian studies.

  10. Gastric wall shortening in early gastric cancer: upper gastrointestinal series and pathologic correlation

    International Nuclear Information System (INIS)

    Kim, In Jae; Choi, Chul Soon; Kim, Eun Ah; Kim, Kyu Sun; Yun, Ku Sub; Kim, Ho Chul; Bae, Sang Hun; Kang, Gu; Shin, Hyung Sik

    1995-01-01

    To investigate the causes of gastric wall shortening in early gastric cancer, upper gastrointestinal study was correlated with pathologic findings. We evaluated 41 cases (M:F = 1.7:1, average age = 49) of early gastric cancer, retrospectively. The gastric wall shortening were classified as Grade I; none, Grade II; intermediate, and Grade III; prominent. Pathologic findings such as size of lesions, depth of tumor invasion, degree of the submucosal fibrosis, degree of thickness of the submucosa and muscularis propria, and morphologic patterns of lesions including conversing mucosal folds were correlated with the degree of gastric wall shortening on upper gastrointestinal series. Submucosal fibrosis was present in 4 cases in Grade I (n = 21), 4 cases in Grade II (n = 6) and 8 cases in Grade III (n = 10). Positive conversing mucosal folds were seen in 5 cases in Grade I (n = 17), 0 case in Grade II (n = 2) and 9 cases in Grade III (n = 9). Gastric wall shortening was significantly associated with submucosal fibrosis and conversing mucosal folds of early gastric cancer. (ρ = 0.0001, and ρ = 0.02, respectively) Upper gastrointestinal finding of gastric wall protrusion in patients with early gastric cancer should not misinterprete as advanced gastric cancer since the finding could be a result of submucosal fibrosis

  11. Spironolactone and risk of upper gastrointestinal events: population based case-control study

    NARCIS (Netherlands)

    K.M.C. Verhamme (Katia); G. Mosis (Georgio); B.H.Ch. Stricker (Bruno); M.C.J.M. Sturkenboom (Miriam); J.P. Dieleman (Jeanne)

    2006-01-01

    textabstractOBJECTIVE: To confirm and quantify any association between spironolactone and upper gastrointestinal bleeding and ulcers. DESIGN: Population based case-control study. SETTING: A primary care information database in the Netherlands. PARTICIPANTS: All people on the

  12. Limitations of Routine Verification of Nasogastric Tube Insertion Using X-Ray and Auscultation: Two Case Reports of Life-Threatening Complications.

    Science.gov (United States)

    Nejo, Takahide; Oya, Soichi; Tsukasa, Tsuchiya; Yamaguchi, Naomi; Matsui, Toru

    2016-12-01

    Several bedside approaches used in combination with thoracoabdominal X-ray are widely used to avoid severe complications that have been reported during nasogastric tube management. Although confirmation by X-ray is considered the gold standard, it is not yet perfect. We present 2 cases of rare complications in which the routine verification methods could not detect all the complications related to the nasogastric tube placement. Case 1 was a 17-year-old male who presented with a brain tumor and repeatedly required nasogastric tube placement. Despite normal auscultatory and X-ray findings, the patient's condition deteriorated rapidly after resuming the enteral nutrition (EN). Computed tomography images showed the presence of hepatic portal venous gas (HPVG). Urgent upper gastrointestinal endoscopy showed esophagogastric submucosal tunneling of the tube that required an emergency open total gastrectomy. Case 2 was a 76-year-old man with long-term EN after stroke. While the last auscultatory verification was normal, he suddenly developed extensive HPVG due to gastric mucosal injury following EN, which resulted in progressive intestinal necrosis, general peritonitis, and death. These 2 cases indicated that routine verification methods consisting of auscultation and X-ray may not be completely reliable, and the awareness of the limitations of these methods should be reaffirmed because expeditious examinations and necessary interventions are critical in preventing life-threatening complications.

  13. Validation of the Rockall risk scoring system in upper gastrointestinal bleeding

    NARCIS (Netherlands)

    Vreeburg, E. M.; Terwee, C. B.; Snel, P.; Rauws, E. A.; Bartelsman, J. F.; Meulen, J. H.; Tytgat, G. N.

    1999-01-01

    Several scoring systems have been developed to predict the risk of rebleeding or death in patients with upper gastrointestinal bleeding (UGIB). These risk scoring systems have not been validated in a new patient population outside the clinical context of the original study. To assess internal and

  14. Endoscopic evaluation of upper and lower gastro-intestinal bleeding

    Directory of Open Access Journals (Sweden)

    Emeka Ray-Offor

    2015-01-01

    Full Text Available Introduction: A myriad of pathologies lead to gastro-intestinal bleeding (GIB. The common clinical presentations are hematemesis, melena, and hematochezia. Endoscopy aids localization and treatment of these lesions. Aims: The aim was to study the differential diagnosis of GIB emphasizing the role of endoscopy in diagnosis and treatment of GIB. Patients and Methods: A prospective study of patients with GIB referred to the Endoscopy unit of two health facilities in Port Harcourt Nigeria from February 2012 to August 2014. The variables studied included: Demographics, clinical presentation, risk score, endoscopic findings, therapeutic procedure, and outcome. Data were collated and analyzed using SPSS version 20 software. Results: A total of 159 upper and lower gastro-intestinal (GI endoscopies were performed during the study period with 59 cases of GI bleeding. There were 50 males and 9 females with an age range of 13-86 years (mean age 52.4 ΁ 20.6 years. The primary presentations were hematochezia, hematemesis, and melena in 44 (75%, 9 (15%, and 6 (10% cases, respectively. Hemorrhoids were the leading cause of lower GIB seen in 15 cases (41%. The majority of pathologies in upper GIB were seen in the stomach (39%: Gastritis and benign gastric ulcer. Injection sclerotherapy was successfully performed in the hemorrhoids and a case of gastric varices. The mortality recorded was 0%. Conclusion: Endoscopy is vital in the diagnosis and treatment of GIB. Gastritis and Haemorrhoid are the most common causes of upper and lower GI bleeding respectively, in our environment

  15. X-ray diagnostic features of acute bleeding ulcers of the stomach and duodenum

    International Nuclear Information System (INIS)

    Shcherbatenko, M.K.; Selina, I.E.; Chekalina, M.I.

    1996-01-01

    The paper is based on the analysis of clinical, X-ray, and morphological studies in 74 patients with massive gastrointestinal hemorrhage. The paper presents the specific features of X-ray studies of patients with bleeding gastroduodenal ulcers. X-ray studies shout be twice performed in these patients. The first study is conducted if gastroscopic findings are unclear, the repeated one is carried out while assessing changes in disease regression. X-ray diagnosis of bleeding ulcers is determined by their sites and the nature of an ulcerous process. The X-ray diagnosis of chronic callous gastric ulcers accompanied by hemorrhage was based on the detection of two direct symptoms of a niche on the gastric outlines and configuration and an inflammatory mound on the gastric outline and configuration. That of chronic bleeding ulcers of the duodenal bulb is based not only on searches niche, but other signs of the disease - the deformed organ, and the magnitude of a periprocess. 10 refs., 5 figs

  16. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  17. Upper Gastrointestinal Tract Motility Disorders in Women, Gastroparesis, and Gastroesophageal Reflux Disease.

    Science.gov (United States)

    Zia, Jasmine K; Heitkemper, Margaret M

    2016-06-01

    This article reviews the sex differences in upper gastrointestinal (GI) motility for both healthy and common dysmotility conditions. It focuses on gastroesophageal reflux disease and other esophageal motor disorders for the esophagus and on gastroparesis and accelerated gastric emptying for the stomach. It also describes differences in upper GI motility signs and symptoms during each female hormonal stage (ie, menstrual cycle, pregnancy, perimenopause, menopause) for both healthy participants and those suffering from one of the aforementioned upper GI dysmotility conditions. More research still needs to be conducted to better understand sex differences in upper GI motility. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Tranexamic Acid in the Management of Upper Gastrointestinal Bleeding: an Evidence-based Case Report

    Directory of Open Access Journals (Sweden)

    Nur Atikah

    2015-04-01

    Full Text Available Aim: to review the effectiveness of tranexamic acid therapy which has been proposed to reduce bleeding and in turn lower mortality rate. Methods: following literature searching based on our clinical question on Cochrane Library, PubMed, Clinical Key, EBSCO, Science Direct and Proquest, one systematic review that includes seven randomized controlled trials is obtained. The article meets validity and relevance criteria. Results: the systematic review found that there is no any clear evidence between intervention and control groups in term of mortality. Conclusion: the use of tranexamic acid to reduce mortality in patients with upper gastrointestinal bleeding is not recommended. Key words: tranexamic acid, mortality, upper gastrointestinal bleeding.

  19. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  20. Phantom gastric mucosa for evaluating computed radiography in double-contrast upper gastrointestinal examinations

    International Nuclear Information System (INIS)

    Murakami, M.; Watanabe, H.; Nakata, H.

    1996-01-01

    To test the clinical usefulness of computed radiography (CR) with a storage phosphor plate in upper gastrointestinal radiographic examinations, a newly devised phantom gastric mucosa was used. Simulated small elevated and depressed lesions were created on a phantom gastric mucosa made from a styrofoam 'plate'. Twenty-four sets of each CR and screen-film radiographs (SR) were obtained using phototimed exposures. Receiver operating characteristic (ROC) study and visual ranking using these images were performed. There was no significant difference between the ROC curves of CR and SR. By visual ranking, CR was equal to or better than SR in most cases. In no case was SR definitely superior to CR. CR can be safely applied in upper gastrointestinal roentgenologic examinations. (orig.)

  1. Alarm symptoms of upper gastrointestinal cancer and contact to general practice

    DEFF Research Database (Denmark)

    Rasmussen, Sanne; Larsen, Pia Veldt; Svendsen, Rikke Pilsgaard

    2015-01-01

    INTRODUCTION: Survival of upper gastrointestinal (GI) cancer depends on early stage diagnosis. Symptom-based guidelines and fast-track referral systems have been implemented for use in general practice. To improve diagnosis of upper GI cancer, knowledge on prevalence of alarm symptoms...... between 1.1% ("repeated vomiting") and 3.4% ("difficulty swallowing"). Women had higher odds of experiencing "repeated vomiting" and "persistent and recent-onset abdominal pain", but lower odds of experiencing "upper GI bleeding". The proportion of people contacting their GP with each of the four specific...... alarm symptoms ranged from 24.3% ("upper GI bleeding") to 39.9% ("repeated vomiting"). For each combination of two specific alarm symptoms, at least 52% contacted their GP. CONCLUSION: The specific alarm symptoms of upper GI cancer are not very prevalent in the general population. The proportion of GP...

  2. Upper gastrointestinal sensory-motor dysfunction in diabetes mellitus

    Science.gov (United States)

    Zhao, Jing-Bo; Frøkjær, Jens Brøndum; Drewes, Asbjørn Mohr; Ejskjaer, Niels

    2006-01-01

    Gastrointestinal (GI) sensory-motor abnormalities are common in patients with diabetes mellitus and may involve any part of the GI tract. Abnormalities are frequently sub-clinical, and fortunately only rarely do severe and life-threatening problems occur. The pathogenesis of abnormal upper GI sensory-motor function in diabetes is incompletely understood and is most likely multi-factorial of origin. Diabetic autonomic neuropathy as well as acute suboptimal control of diabetes has been shown to impair GI motor and sensory function. Morphological and biomechanical remodeling of the GI wall develops during the duration of diabetes, and may contribute to motor and sensory dysfunction. In this review sensory and motility disorders of the upper GI tract in diabetes is discussed; and the morphological changes and biomechanical remodeling related to the sensory-motor dysfunction is also addressed. PMID:16718808

  3. Effect of hyoscine butylbromide on gastroesophageal reflux in barium studies of the upper gastrointestinal tract

    Energy Technology Data Exchange (ETDEWEB)

    McLaughlin, R.F.; Mathieson, J.R.; Chipperfield, P.M.; Grymaloski, M.R.; Wong, A.D.

    1994-12-01

    The presence or absence and severity of gastroesophageal reflux before and after intravenous injection of 120 mg Buscopan were evaluated in 112 consecutive patients undergoing upper gastrointestinal examination. The study was undertaken to test the hypothesis that hyoscine butylbromide (Buscopan) could artificially induce gastroesophageal reflux during barium examination of the upper intestinal tract. Gastroesophageal reflux was seen in 49 (44%) of the patients. There was no significant difference in the overall occurrence or degree of gastroesophageal reflux before and after injection of Buscopan. The routine use of Buscopan was therefore unlikely to spuriously increase the frequency or degree of gastroesophageal reflux observed on upper gastrointestinal barium studies. The study also showed that Buscopan had a satisfactory antispasmodic effect and few side effects. 7 refs., 1 tab.

  4. Early Period Results and Clinical Characteristics of Upper Gastrointestinal Endoscopy in Sivrihisar State Hospital

    Directory of Open Access Journals (Sweden)

    Ozgur Turk

    2014-12-01

    Full Text Available Aim: Our aim was to identify the characteristics of the patient that performed upper gastrointestinal endoscopy in a new established endoscopy unit of a state hospital. We want to present the spectrum of gastrointestinal diseases in our hospitals region. Material and Method: We analyzed patients upper endoscopy results according to age, sex, complaints, clinical characteristics, type of anesthesia, and the necessity of biopsy. We reviewed 256 patients data between 2013 December-2014 July. All endoscopies were performed by same surgeon. Results: The highest complaint was epigastric pain (n=112, 43, 8%. Other complaints were followed as dyspepsia (n=84, 32.8%, heartburn (n=42, 16.4%, nausea (n=4, 1.6%, vomiting (n=2, 0.8%, dysphagia (n=6, 2.3%. We determined 218 gastritis (85.2%, 64 hiatal hernia (25%, 120 esophagitis (46.9%, 76 duodenitis (29.7%, 4 gastric ulcer (1.6%, 18 duodenal ulcers (7%, 20 bile reflux (7.8%, 26 Gastro esophageal reflux disease (GERD in patients (10.2%. 10 patients reported as normal (3.9%. Biopsy was performed in 186 of the patients. Discussion: Endoscopy can become an early diagnostic examination by increasing the availability of endoscopy. Also alarm symptoms should not be ignored and endoscopy should perform immediately in symptomatic patients. As an early result of upper gastrointestinal endoscopies that performed in this study; gastritis, esophagitis, duodenitis and hiatal hernia are common gastrointestinal diseases in our region.

  5. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  6. X-ray spectroscopy of the mixed morphology supernova remnant W 28 with XMM-Newton

    Science.gov (United States)

    Nakamura, Ryoko; Bamba, Aya; Ishida, Manabu; Yamazaki, Ryo; Tatematsu, Ken'ichi; Kohri, Kazunori; Pühlhofer, Gerd; Wagner, Stefan J.; Sawada, Makoto

    2014-06-01

    We report on spatially resolved X-ray spectroscopy of the north-eastern part of the mixed morphology supernova remnant (SNR) W 28 with XMM-Newton. The observed field of view includes a prominent and twisted shell emission forming the edge of this SNR as well as part of the center-filled X-ray emission brightening toward the south-west edge of the field of view. The shell region spectra are in general represented by an optically thin thermal plasma emission in collisional ionization equilibrium with a temperature of ˜ 0.3 keV and a density of ˜ 10 cm-3, which is much higher than the density obtained for inner parts. In contrast, we detected no significant X-ray flux from one of the TeV γ-ray peaks with an upper-limit flux of 2.1 × 10-14 erg cm-2 s-1 in the 2-10 keV band. The large flux ratio of TeV to X-ray, larger than 16, and the spatial coincidence of the molecular cloud and the TeV γ-ray emission site indicate that the TeV γ-ray of W 28 is π0-decay emission originating from collisions between accelerated protons and molecular cloud protons. Comparing the spectrum in the TeV band and the X-ray upper limit, we obtained a weak upper limit on the magnetic field strength B ≲ 1500 μG.

  7. Tranexamic acid for upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Bennett, Cathy; Klingenberg, Sarah Louise; Langholz, Ebbe

    2014-01-01

    Background Tranexamic acid reduces haemorrhage through its antifibrinolytic effects. In a previous version of the present review, we found that tranexamic acid may reduce mortality. This review includes updated searches and new trials.Objectives To assess the effects of tranexamic acid versus......-effect and random-effects model meta-analyses and presented results as risk ratios (RRs) with 95% confidence intervals (CIs) and used I² as a measure of between-trial heterogeneity. We analysed tranexamic acid versus placebo or no intervention and tranexamic acid versus antiulcer drugs separately. To analyse...... sources of heterogeneity and robustness of the overall results, we performed subgroup, sensitivity and sequential analyses.Main results We included eight randomised controlled trials on tranexamic acid for upper gastrointestinal bleeding. Additionally, we identified one large ongoing pragmatic randomised...

  8. X-ray pickup device for dental radiography

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    The X-ray tube has got a tubular extension within which a W-shaped target is arranged and which can be inserted into the mouth opening of the patient. The target is inclined with respect to the axis of the beam of electrons striking it in such a way, that the X-radiation emitted by it is received either by the upper or the lower row of teeth, including the root area. A screen mounted on the extension causes only these semicircular areas to be irradiated. An X-ray film holder is also fastened to the extension and covers mouth and cheeks of the patient from outside. The focal spot on the target is adjustable so that a sharp picture can be produced. (RW) [de

  9. Upper gastrointestinal endoscopy in patients aged 85 years or more. Results of a feasibility study in a district general hospital.

    NARCIS (Netherlands)

    Kouwen, M.C.A. van; Drenth, J.P.H.; Verhoeven, H.M.; Bos, L.P.; Engels, L.G.

    2003-01-01

    We performed a cross sectional analysis of the feasibility and yield of upper gastrointestinal endoscopy (UGE) in a cohort of patients aged 85 years or more. The study involved 218 patients who underwent diagnostic upper gastrointestinal endoscopy in a district general hospital between 1994 and

  10. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  11. Radiation dose estimates for oral agents used in upper gastrointestinal disease

    International Nuclear Information System (INIS)

    Siegel, J.A.; Wu, R.K.; Knight, L.C.; Zelac, R.E.; Stern, H.S.; Malmud, L.S.

    1983-01-01

    Radiation dosimetry was calculated for a number of orally administered radiopharmaceuticals used for study of upper gastrointestinal function. These include: Tc-99m sulfur colloid in water, in a cooked egg, and in chicken liver labeled in vivo; In-111 DTPA; Tc-99m DTPA; In-113m DTPA; Tc-99m ovalbumin in cooked egg; and In-111 colloid in chicken liver labeled in vivo. Radiation burdens to the stomach, small intestine, upper and lower large intestine, ovaries, testes, and total body are calculated for each preparation

  12. Management of acute nonvariceal upper gastrointestinal bleeding: Current policies and future perspectives

    NARCIS (Netherlands)

    I.L. Holster (Ingrid); E.J. Kuipers (Ernst)

    2012-01-01

    textabstractAcute upper gastrointestinal bleeding (UGIB) is a gastroenterological emergency with a mortality of 6%-13%. The vast majority of these bleeds are due to peptic ulcers. Nonsteroidal anti-inflammatory drugs and Helicobacter pylori are the main risk factors for peptic ulcer disease.

  13. Laboratory test variables useful for distinguishing upper from lower gastrointestinal bleeding.

    Science.gov (United States)

    Tomizawa, Minoru; Shinozaki, Fuminobu; Hasegawa, Rumiko; Shirai, Yoshinori; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Ishige, Naoki

    2015-05-28

    To distinguish upper from lower gastrointestinal (GI) bleeding. Patient records between April 2011 and March 2014 were analyzed retrospectively (3296 upper endoscopy, and 1520 colonoscopy). Seventy-six patients had upper GI bleeding (Upper group) and 65 had lower GI bleeding (Lower group). Variables were compared between the groups using one-way analysis of variance. Logistic regression was performed to identify variables significantly associated with the diagnosis of upper vs lower GI bleeding. Receiver-operator characteristic (ROC) analysis was performed to determine the threshold value that could distinguish upper from lower GI bleeding. Hemoglobin (P = 0.023), total protein (P = 0.0002), and lactate dehydrogenase (P = 0.009) were significantly lower in the Upper group than in the Lower group. Blood urea nitrogen (BUN) was higher in the Upper group than in the Lower group (P = 0.0065). Logistic regression analysis revealed that BUN was most strongly associated with the diagnosis of upper vs lower GI bleeding. ROC analysis revealed a threshold BUN value of 21.0 mg/dL, with a specificity of 93.0%. The threshold BUN value for distinguishing upper from lower GI bleeding was 21.0 mg/dL.

  14. Radiation dose calculations for orally administered radio-pharmaceuticals in upper gastrointestinal disease

    International Nuclear Information System (INIS)

    Wu, R.K.; Malmud, L.S.; Knight, L.C.; Siegel, J.A.; Stern, H.; Zelac, R.

    1983-01-01

    Radiation burden estimates for upper gastrointestinal function studies employing the following orally administered radiopharmaceuticals are reported. Technetium 99m sulfur colloid (Tc-99m-SC) in water, Indium-111-DTPA in water, Tc-99m-DTPA in water, Indium-113m DTPA in water, Tc-99m Ovalbumin, Tc-99m sulfur colloid in a cooked egg, Tc-99m sulfur colloid in vivo labeled chicken liver, and Indium-111 colloid in vivo labeled chicken liver. Orally administered radiopharmaceuticals for upper gastrointestinal studies afford clinician and investigator valuable clinical and physiologic information not previously obtainable using other techniques. The radiation burden to the patient from single or sequential studies is acceptable in comparison to fluoroscopy which results in approximately 5000 millirem per minute of exposure. The variety of preparations listed above should make these types of studies available in any routinely equipped nuclear medicine radiopharmacy laboratory

  15. Hemostatic powder TC-325 in the management of upper and lower gastrointestinal bleeding: a two-year experience at a single institution.

    Science.gov (United States)

    Chen, Yen-I; Barkun, Alan; Nolan, Sabrina

    2015-02-01

    TC-325 is a novel endoscopic hemostatic powder. Our aim was to describe a single-center experience with the use of TC-325 in the upper and lower gastrointestinal tract, while for the first time attempting to determine how long the powder remains on a lesion. The charts of consecutive patients receiving TC-325 therapy between July 2011 and July 2013 were reviewed retrospectively. Primary endpoints included immediate hemostasis and early rebleeding (≤ 72 hours). Overall, 60 patients received 67 treatments with TC-325: 21 for nonmalignant nonvariceal upper gastrointestinal bleeding, 19 for malignant upper gastrointestinal bleeding, 11 for lower gastrointestinal bleeding, and 16 for intra-procedural bleeding. Immediate hemostasis was achieved in 66 cases (98.5 %), with 6 cases (9.5 %) of early rebleeding. No serious adverse events were noted. No TC-325 powder was identified in the 11 patients who underwent second-look endoscopy, performed within 24 hours in 4 patients. TC-325 appears safe and effective for managing bleeding in the upper and lower gastrointestinal tract with a variety of causes. The time during which the powder remains in the gastrointestinal tract is short, with complete elimination from the gastrointestinal tract as early as within 24 hours after use. © Georg Thieme Verlag KG Stuttgart · New York.

  16. X-ray irradiation on blood products for the purpose of prevention of PT-GVHD

    International Nuclear Information System (INIS)

    Tayama, Tatsuya; Naohara, Tooru; Haneda, Kenji; Juji, Takeo.

    1990-01-01

    X-ray irradiation on blood products is a common method to prevent the risk of inducing PT-GVHD, and has recently become to be used in Japan. We have tried X-ray irradiation on WB, CRC and PC using HITACHI X-ray Irradiation Apparatus MBR1520R, and studied its practical usefulness. In case of irradiation on blood bags as the minimum dose of 1,500 rads, these conditions are thought to be practical: 1) the use of 1.0 mm Al filter, 2) the distance of 550 nm from X-ray source, and 3) irradiation on 4 bags at the same time. But, it has also been noticed that total doses and qualities of X-ray absorbed into blood were different between upper and lower side of the bag. Bloods on upper side absorbed much doses and a wide range of X-ray, on the other hand, bloods on lower side absorbed less doses and hard X-ray. In these conditions, irradiated lymphocytes showed a complete inhibition of thymidine uptake in MLC test, still had 15% of activity in PHA stimulation. The qualities of other blood components have not changed before and after irradiation. X-ray irradiation is useful in a routine work of blood center, but problems of proper doses and a uniformity of irradiation are remained to be solved. (author)

  17. Transcatheter Arterial Embolization of Nonvariceal Upper Gastrointestinal Bleeding with N-Butyl Cyanoacrylate

    International Nuclear Information System (INIS)

    Jae, Hwan Jun; Chung, Jin Wook; Jung, Ah Young; Lee, Whal; Park, Jae Hyung

    2007-01-01

    To evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with N-Butyl Cyanoacrylate (NBCA) for nonvariceal upper gastrointestinal bleeding. Between March 1999 and December 2002, TAE for nonvariceal upper gastrointestinal bleeding was performed in 93 patients. The endoscopic approach had failed or was discarded as an approach for control of bleeding in all study patients. Among the 93 patients NBCA was used as the primary embolic material for TAE in 32 patients (28 men, four women; mean age, 59.1 years). The indications for choosing NBCA as the embolic material were: inability to advance the microcatheter to the bleeding site and effective wedging of the microcatheter into the bleeding artery. TAE was performed using 1:1 1:3 mixtures of NBCA and iodized oil. The angiographic and clinical success rate, recurrent bleeding rate, procedure related complications and clinical outcomes were evaluated. The angiographic and clinical success rates were 100% and 91% (29/32), respectively. There were no serious ischemic complications. Recurrent bleeding occurred in three patients (9%) and they were managed with emergency surgery (n = 1) and with a successful second TAE (n = 2). Eighteen patients (56%) had a coagulopathy at the time of TAE and the clinical success rate in this group of patients was 83% (15/18). TAE with NBCA is a highly effective and safe treatment modality for nonvariceal upper gastrointestinal bleeding, especially when it is not possible to advance the microcatheter to the bleeding site and when the patient has a coagulopathy

  18. Transcatheter Arterial Embolization of Nonvariceal Upper Gastrointestinal Bleeding with N-Butyl Cyanoacrylate

    Energy Technology Data Exchange (ETDEWEB)

    Jae, Hwan Jun; Chung, Jin Wook; Jung, Ah Young; Lee, Whal; Park, Jae Hyung [Seoul National University Hospital, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2007-02-15

    To evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with N-Butyl Cyanoacrylate (NBCA) for nonvariceal upper gastrointestinal bleeding. Between March 1999 and December 2002, TAE for nonvariceal upper gastrointestinal bleeding was performed in 93 patients. The endoscopic approach had failed or was discarded as an approach for control of bleeding in all study patients. Among the 93 patients NBCA was used as the primary embolic material for TAE in 32 patients (28 men, four women; mean age, 59.1 years). The indications for choosing NBCA as the embolic material were: inability to advance the microcatheter to the bleeding site and effective wedging of the microcatheter into the bleeding artery. TAE was performed using 1:1 1:3 mixtures of NBCA and iodized oil. The angiographic and clinical success rate, recurrent bleeding rate, procedure related complications and clinical outcomes were evaluated. The angiographic and clinical success rates were 100% and 91% (29/32), respectively. There were no serious ischemic complications. Recurrent bleeding occurred in three patients (9%) and they were managed with emergency surgery (n = 1) and with a successful second TAE (n = 2). Eighteen patients (56%) had a coagulopathy at the time of TAE and the clinical success rate in this group of patients was 83% (15/18). TAE with NBCA is a highly effective and safe treatment modality for nonvariceal upper gastrointestinal bleeding, especially when it is not possible to advance the microcatheter to the bleeding site and when the patient has a coagulopathy.

  19. The X-ray Telescope of the CAST Experiment

    CERN Document Server

    Kotthaus, Rainer; Friedrich, P.; Kang, D.; Hartmann, R.; Kuster, M.; Lutz, G.; Strüder, L.

    2005-01-01

    The CERN Axion Solar Telescope (CAST) searches for solar axions employing a 9 Tesla superconducting dipole magnet equipped with 3 independent detection systems for X-rays from axion-photon conversions inside the 10 m long magnetic field. Results of the first 6 months of data taking in 2003 imply a 95 % CL upper limit on the axion-photon coupling constant of 1.16x10(-10) GeV(-1) for axion masses < 0.02 eV. The most sensitive detector of CAST is a X-ray telescope consisting of a Wolter I type mirror system and a fully depleted pn-CCD as focal plane detector. Exploiting the full potential of background suppression by focussing X-rays emerging from the magnet bore, the axion sensitivity obtained with telescope data taken in 2004, for the first time in a controlled laboratory experiment, will supersede axion constraints derived from stellar energy loss arguments.

  20. UPPER GASTROINTESTINAL TRACT HEMORRHAGE AND NONSTEROIDALANTIINFLAMMATORY DRUGS (NSAIDs – A 5-YEAR PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Pavel Skok

    2002-03-01

    Full Text Available Background. Adverse effects of nonsteroidal antiinflammatory drugs (NSAIDs are a common cause of digestive tract hemorrhage.Study aims. The purpose of the study was to ascertain the percent of patients taking NSAIDs with upper digestive tract hemorrhage.Type of study. Prospective, analytical.Patients and methods. The study includes patients in which urgent endoscopic investigations of the upper digestive tract were carried out due to gastrointestinal hemorrhage between 1 January 1994 and 31 December 1998.Results. 3366 patients were investigated: 1222 women and 2144 men; the average age of our patients was 57.5 years (SD ± 17.1, a 2–97 year span. In 2905 patients (86.3% the source of bleeding was confirmed in the upper gastrointestinal tract. Among our patients 55% were aged over 60 years, 26.7% were older than 80 years. Sequelae of peptic ulcer disease were the most significant cause of gastrointestinal hemorrhage, in 47.7% of our patients (1387/2905. In the last week prior to bleeding, 19% of patients (552/2905 were taking regularly NSAIDs, corticosteroids, salycilates or anticoagulant therapy at least in single daily dose. The majority of patients, 94.5%, were taking NSAIDs or salycilates. Among NSAIDs they were taking most often ketoprofen, diclofenac or naproxen/ naproxen natrium, less often ibuprofen, nabumeton, etodolac or piroxicam.Conclusions. Upper digestive tract hemorrhage is a serious complication of NSAIDs medication, particularly in older patients

  1. Synchrotron x-ray microbeam characteristics for x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Iida, Atsuo; Noma, Takashi

    1995-01-01

    X-ray fluorescence analysis using a synchrotron x-ray microprobe has become an indispensable technique for non-destructive micro-analysis. One of the most important parameters that characterize the x-ray microbeam system for x-ray fluorescence analysis is the beam size. For practical analysis, however, the photon flux, the energy resolution and the available energy range are also crucial. Three types of x-ray microbeam systems, including monochromatic and continuum excitation systems, were compared with reference to the sensitivity, the minimum detection limit and the applicability to various types of x-ray spectroscopic analysis. 16 refs., 5 figs

  2. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  3. An observational European study on clinical outcomes associated with current management strategies for non-variceal upper gastrointestinal bleeding (ENERGIB-Turkey).

    Science.gov (United States)

    Mungan, Zeynel

    2012-01-01

    This observational, retrospective cohort study assessed outcomes of the current management strategies for nonvariceal upper gastrointestinal bleeding in several European countries (Belgium, Greece, Italy, Norway, Portugal, Spain, and Turkey) (NCT00797641; ENERGIB). Turkey contributed 23 sites to this study. Adult patients (≥18 years old) consecutively admitted to hospital and who underwent endoscopy for overt non-variceal upper gastrointestinal bleeding (hematemesis, melena or hematochezia, with other clinical/laboratory evidence of acute upper GI blood loss) were included in the study. Data were collected from patient medical records regarding bleeding continuation, re-bleeding, pharmacological treatment, surgery, and mortality during a 30-day follow-up period. A total of 423 patients (67.4% men; mean age: 57.8 ± 18.9 years) were enrolled in the Turkish study centers, of whom 96.2% were admitted to hospital with acute non-variceal upper gastrointestinal bleeding. At admission, the most common symptom was melena (76.1%); 28.6% of patients were taking aspirin, 19.9% were on non-steroidal anti-inflammatory drugs, and 7.3% were on proton pump inhibitors. The most common diagnoses were duodenal (45.2%) and gastric (27.7%) ulcers and gastritis/gastric erosions (26.2%). Patients were most often managed in general medical wards (45.4%). A gastrointestinal team was in charge of treatment in 64.8% of cases. Therapeutic procedures were performed in 32.4% of patients during endoscopy. After the endoscopy, most patients (94.6%) received proton pump inhibitors. Mean (SD) hospital stay was 5.36 ± 4.91 days. The cumulative proportions of continued bleeding/re-bleeding, complications and mortality within 30 days of the non-variceal upper gastrointestinal bleeding episode were 9.0%, 5.7% and 2.8%, respectively. In the Turkish sub-group of patients, the significant risk factors for bleeding continuation or re-bleeding were age >65 years, presentation with hematemesis or shock

  4. Hard X-ray irradiation of cosmic silicate analogs: structural evolution and astrophysical implications

    Science.gov (United States)

    Gavilan, L.; Jäger, C.; Simionovici, A.; Lemaire, J. L.; Sabri, T.; Foy, E.; Yagoubi, S.; Henning, T.; Salomon, D.; Martinez-Criado, G.

    2016-03-01

    Context. Protoplanetary disks, interstellar clouds, and active galactic nuclei contain X-ray-dominated regions. X-rays interact with the dust and gas present in such environments. While a few laboratory X-ray irradiation experiments have been performed on ices, X-ray irradiation experiments on bare cosmic dust analogs have been scarce up to now. Aims: Our goal is to study the effects of hard X-rays on cosmic dust analogs via in situ X-ray diffraction. By using a hard X-ray synchrotron nanobeam, we seek to simulate cumulative X-ray exposure on dust grains during their lifetime in these astrophysical environments and provide an upper limit on the effect of hard X-rays on dust grain structure. Methods: We prepared enstatite (MgSiO3) nanograins, which are analogs to cosmic silicates, via the melting-quenching technique. These amorphous grains were then annealed to obtain polycrystalline grains. These were characterized via scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM) before irradiation. Powder samples were prepared in X-ray transparent substrates and were irradiated with hard X-rays nanobeams (29.4 keV) provided by beamline ID16B of the European Synchrotron Radiation Facility (Grenoble). X-ray diffraction images were recorded in transmission mode, and the ensuing diffractograms were analyzed as a function of the total X-ray exposure time. Results: We detected the amorphization of polycrystalline silicates embedded in an organic matrix after an accumulated X-ray exposure of 6.4 × 1027 eV cm-2. Pure crystalline silicate grains (without resin) do not exhibit amorphization. None of the amorphous silicate samples (pure and embedded in resin) underwent crystallization. We analyze the evolution of the polycrystalline sample embedded in an organic matrix as a function of X-ray exposure. Conclusions: Loss of diffraction peak intensity, peak broadening, and the disappearance of discrete spots and arcs reveal the amorphization

  5. [Application of degree of portal systemic shunting in assessing upper gastrointestinal bleeding in patients with schistosomiasis cirrhosis].

    Science.gov (United States)

    Shuai, Ju; Ying, Li; Chang-Xue, Ji; Biao, Zhang

    2017-03-27

    To discuss the application of the degree of portal systemic shunting in assessing the upper gastrointestinal bleeding in patients with hepatic schistosomiasis. Thirty-three patients with upper gastrointestinal bleeding caused by hepatic schistosomiasis (a bleeding group) and 29 schistosomiasis cirrhosis patients without bleeding (a non-bleeding group) were enrolled as investigation subjects in Jinshan Hospital. The subjects were scanned by the 128 abdominal slice spiral CT. The portal systemic shunting vessels were reconstructed by using thin slab maximum intensity projection (TSMIP) and multiplanar reconstruction (MPR). The degrees of the shunting vessels of the subjects were evaluated and compared, and the relationship between upper gastrointestinal bleeding and the degree of the shunting was analyzed. In the bleeding group, the occurrence rates of the shunting vessels were found as follows: 86.4% in left gastric varices, 68.2% in short gastric varices, 50.0% in esophageal varices, 50.0% in para-esophageal varices, 37.9% in gastric varices, 69.7% in gastric-renal varices, 51.5% in spleen-renal varices, 25.8% in abdominal wall varices, 15.2% in omentum varices, 63.6% in para-splenic varices, 34.8% in umbilical varices, 40.9% in retroperitoneal-paravertebral varices, and 36.4% in mesenteric varices. In the bleeding group, the occurrence rates and the degree of shunt were significantly higher than those in the non-bleeding group in esophageal varices, esophageal vein, left gastric vein and gastric varices (all P upper gastrointestinal bleeding in patients with hepatic schistosomiasis. The patents with higher degree of the shunting vessels have a higher risk of gastrointestinal bleeding.

  6. Non-variceal upper gastrointestinal bleeding in cirrhotic patients in Nile Delta.

    Science.gov (United States)

    Gabr, Mamdouh Ahmed; Tawfik, Mohamed Abd El-Raouf; El-Sawy, Abd Allah Ahmed

    2016-01-01

    Acute upper gastrointestinal bleeding (AUGIB) in cirrhotic patients occurs mainly from esophageal and gastric varices; however, quite a large number of cirrhotic patients bleed from other sources as well. The aim of the present work is to determine the prevalence of non-variceal UGIB as well as its different causes among the cirrhotic portal hypertensive patients in Nile Delta. Emergency upper gastrointestinal (UGI) endoscopy for AUGIB was done in 650 patients. Out of these patients, 550 (84.6%) patients who were proved to have cirrhosis were the subject of the present study. From all cirrhotic portal hypertensive patients, 415 (75.5%) bled from variceal sources (esophageal and gastric) while 135 (24.5%) of them bled from non-variceal sources. Among variceal sources of bleeding, esophageal varices were much more common than gastric varices. Peptic ulcer was the most common non-variceal source of bleeding. Non-variceal bleeding in cirrhosis was not frequent, and sources included peptic ulcer, portal hypertensive gastropathy, and erosive disease of the stomach and duodenum.

  7. X-ray astronomy

    International Nuclear Information System (INIS)

    Culhane, J.L.; Sanford, P.W.

    1981-01-01

    X-ray astronomy has been established as a powerful means of observing matter in its most extreme form. The energy liberated by sources discovered in our Galaxy has confirmed that collapsed stars of great density, and with intense gravitational fields, can be studied by making observations in the X-ray part of the electromagnetic spectrum. The astronomical objects which emit detectable X-rays include our own Sun and extend to quasars at the edge of the Universe. This book describes the history, techniques and results obtained in the first twenty-five years of exploration. Space rockets and satellites are essential for carrying the instruments above the Earth's atmosphere where it becomes possible to view the X-rays from stars and nebulae. The subject is covered in chapters, entitled: the birth of X-ray astronomy; the nature of X-radiation; X-rays from the Sun; solar-flare X-rays; X-rays from beyond the solar system; supernovae and their remnants; X-rays from binary stars; white dwarfs and neutron stars; black holes; X-rays from galaxies and quasars; clusters of galaxies; the observatories of the future. (author)

  8. THE IDENTIFICATION OF THE X-RAY COUNTERPART TO PSR J2021+4026

    Energy Technology Data Exchange (ETDEWEB)

    Weisskopf, Martin C.; Elsner, Ronald F.; O' Dell, Stephen L.; Tennant, Allyn F. [NASA Marshall Space Flight Center, Space Science Office, VP62, Huntsville, AL 35812 (United States); Romani, Roger W. [Department of Physics, Stanford University, Stanford, CA 94305 (United States); Razzano, Massimiliano [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Belfiore, Andrea; Saz Parkinson, Pablo; Ziegler, Marcus; Dormody, Michael [Santa Cruz Institute for Particle Physics, Department of Physics, University of California at Santa Cruz, Santa Cruz, CA 95064 (United States); Ray, Paul S. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States); Kerr, Matthew [Kavli Institute for Particle Astrophysics and Cosmology, Stanford University, 452 Lomita Mall, Stanford, CA 94305 (United States); Harding, Alice [Astrophysics Science Division, NASA Goddard Space Flight Center, Code 663, Greenbelt, MD 20771 (United States); Swartz, Douglas A. [Universities Space Research Association, NASA Marshall Space Flight Center, Space Science Office, VP62, Huntsville, AL 35812 (United States); Carraminana, Alberto [Instituto Nacional de Astrofisica, Optica y Electronica, Luis Enrique Erro 1, Tonantzintla, Puebla 72840 (Mexico); Becker, Werner; Kanbach, Gottfried [Max-Planck-Institut fuer extraterrestrische Physik, 85741 Garching bei Muenchen (Germany); De Luca, Andrea [INAF-Istituto di Astrofisica Spaziale e Fisica Cosmica, I-20133 Milano (Italy); Thompson, David J. [Astroparticle Physics Laboratory, NASA Goddard Space Flight Center, Code 661, Greenbelt, MD 20771 (United States)

    2011-12-10

    We report the probable identification of the X-ray counterpart to the {gamma}-ray pulsar PSR J2021+4026 using imaging with the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer and timing analysis with the Fermi satellite. Given the statistical and systematic errors, the positions determined by both satellites are coincident. The X-ray source position is R.A. 20{sup h}21{sup m}30.{sup s}733, decl. +40 Degree-Sign 26'46.''04 (J2000) with an estimated uncertainty of 1.''3 combined statistical and systematic error. Moreover, both the X-ray to {gamma}-ray and the X-ray to optical flux ratios are sensible assuming a neutron star origin for the X-ray flux. The X-ray source has no cataloged infrared-to-visible counterpart and, through new observations, we set upper limits to its optical emission of i' > 23.0 mag and r' > 25.2 mag. The source exhibits an X-ray spectrum with most likely both a power law and a thermal component. We also report on the X-ray and visible light properties of the 43 other sources detected in our Chandra observation.

  9. THE IDENTIFICATION OF THE X-RAY COUNTERPART TO PSR J2021+4026

    International Nuclear Information System (INIS)

    Weisskopf, Martin C.; Elsner, Ronald F.; O'Dell, Stephen L.; Tennant, Allyn F.; Romani, Roger W.; Razzano, Massimiliano; Belfiore, Andrea; Saz Parkinson, Pablo; Ziegler, Marcus; Dormody, Michael; Ray, Paul S.; Kerr, Matthew; Harding, Alice; Swartz, Douglas A.; Carramiñana, Alberto; Becker, Werner; Kanbach, Gottfried; De Luca, Andrea; Thompson, David J.

    2011-01-01

    We report the probable identification of the X-ray counterpart to the γ-ray pulsar PSR J2021+4026 using imaging with the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer and timing analysis with the Fermi satellite. Given the statistical and systematic errors, the positions determined by both satellites are coincident. The X-ray source position is R.A. 20 h 21 m 30. s 733, decl. +40°26'46.''04 (J2000) with an estimated uncertainty of 1.''3 combined statistical and systematic error. Moreover, both the X-ray to γ-ray and the X-ray to optical flux ratios are sensible assuming a neutron star origin for the X-ray flux. The X-ray source has no cataloged infrared-to-visible counterpart and, through new observations, we set upper limits to its optical emission of i' > 23.0 mag and r' > 25.2 mag. The source exhibits an X-ray spectrum with most likely both a power law and a thermal component. We also report on the X-ray and visible light properties of the 43 other sources detected in our Chandra observation.

  10. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  11. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  12. Rossi X-Ray Timing Explorer Observation of PSR B0656+14

    International Nuclear Information System (INIS)

    Chang, H.; Ho, C.

    1999-01-01

    PSR B0656+14 was observed by the Rossi X-Ray Timing Explorer (RXTE) with the proportional counter array (PCA) and the high-energy X-ray timing experiment (HEXTE) for 160 ks during 1997 August 22 - September 3. No pulsation was firmly found in the timing analysis, during which the contemporaneous radio ephemeris and various statistical tests were applied in searching for evidence of pulsation. A marginal detection of pulsation at a confidence level of 95.5% based on the H test was found with data in the whole HEXTE energy band. In the energy band of 2-10 keV the RXTE PCA upper limits are about 1 order of magnitude lower than that from ASCA GIS data. If the Compton Gamma Ray Observatory EGRET detection of this pulsar is real, considering the common trait that most EGRET-detected pulsars have a cooling spectrum in hard X-ray and gamma-ray energy bands, the estimated RXTE upper limits indicate a deviation (low-energy turnover) from a cooling spectrum starting from 20 keV or higher. This in turn suggests an outer magnetospheric synchrotron radiation origin for high-energy emissions from PSR B0656+14. The RXTE PCA upper limits also suggest that a reported power-law component based on ASCA SIS data in 1-10 keV fitted jointly with ROSAT data, if real, should be mainly unpulsed. copyright copyright 1999. The American Astronomical Society

  13. Prospective study of cardiac troponin I release in patients with upper gastrointestinal bleeding.

    Science.gov (United States)

    Iser, David M; Thompson, Alexander J V; Sia, Koon Ket; Yeomans, Neville D; Chen, Robert Y M

    2008-06-01

    The rate of cardiac injury in upper gastrointestinal hemorrhage is unclear. The aims of this study were to determine prospectively the risk of cardiac troponin I release and associated adverse cardiac events in patients with acute upper gastrointestinal hemorrhage. From January to September 2003, we prospectively studied patients with documented hematemesis and melena referred to the gastroenterology unit in a tertiary teaching hospital in Melbourne, Australia. Serial assays for cardiac troponin I were performed at 0, 12 and 24 h. Serial creatine kinase levels and electrocardiographs were also performed. Clinical and biochemical data were collected. The primary endpoint was a troponin level >0.5 microg/L within 24 h of recruitment. Various clinical variables were then compared between the groups of patients with or without troponin rise. A total of 156 patients were included in the study. The mean age was 67 years (range 19-96). There were 104 (67%) male patients. A troponin level of greater than 0.5 microg/L was found in 30/156 (19%); 126 (81%) patients had normal troponin levels. Age greater than 65 years, signs of hemodynamic instability at presentation, a recent history of cardiac disease, cardiovascular compromise following endoscopy, and re-bleeding were associated with troponin release. Upper gastrointestinal bleeding is associated with a risk of cardiac injury of up to 19%. Troponin assay could be used to screen for cardiac damage, especially in elderly patients who present with hemodynamic instability.

  14. A Rare Cause of Massive Upper Gastrointestinal Hemorrhage in Immunocompromised Host.

    Science.gov (United States)

    Abdullah, Obai; Pele, Nicole A; Fu, Yumei; Ashraf, Imran; Arif, Murtaza; Bechtold, Matthew L; Grewal, Ajitinder; Hammad, Hazem T

    2012-02-01

    Mucormycosis is an invasive and aggressive opportunistic fungal infection that usually presents with rhinocerebral or pulmonary involvement and rarely involves the gastrointestinal tract. The disease is acute with mortality rate up to 100%. A 68-year-old male was undergoing treatment at a local hospital for COPD exacerbation with IV steroids and antibiotics. Two weeks into his treatment he suddenly developed massive upper GI bleeding and hemodynamic instability that necessitated transfer to our tertiary care hospital for further treatment and management. An urgent upper endoscopy revealed multiple large and deep gastric and duodenal bulb ulcers with stigmata of recent bleeding. The ulcers were treated endoscopically. Biopsies showed fibrinopurulent debris with fungal organisms. Stains highlighted slightly irregular hyphae with rare septa and yeast suspicious for Candida. The patient was subsequently placed on fluconazole. Unfortunately, the patient's general condition continued to worsen and he developed multiorgan failure and died. Autopsy revealed disseminated systemic mucormycosis. Most of the cases of gastrointestinal mucormycosis were reported from the tropics and few were reported in the United States. The disease occurs most frequently in immunocompromised individuals. The rare incidence of GI involvement, acute nature, severity and the problematic identification of the organisms on biopsies make antemortem diagnosis challenging. Treatment includes parenteral antifungals and debridement of the infected tissues. Gastroenterologists should be aware of this rare cause of gastrointestinal bleeding and understand the importance of communication with the reviewing pathologist so that appropriate, and often lifesaving, therapies can be administered in a timely manner.

  15. Search for photon–photon elastic scattering in the X-ray region

    International Nuclear Information System (INIS)

    Inada, T.; Yamaji, T.; Adachi, S.; Namba, T.; Asai, S.; Kobayashi, T.; Tamasaku, K.; Tanaka, Y.; Inubushi, Y.; Sawada, K.; Yabashi, M.; Ishikawa, T.

    2014-01-01

    We report the first results of a search for real photon–photon scattering using X rays. A novel system is developed to split and collide X-ray pulses by applying interferometric techniques. A total of 6.5×10 5 pulses (each containing about 10 11 photons) from an X-ray Free-Electron Laser are injected into the system. No scattered events are observed, and an upper limit of 1.7×10 −24  m 2 (95% C.L.) is obtained on the photon–photon elastic scattering cross section at 6.5 keV

  16. Management of non variceal upper gastrointestinal bleeding: position statement of the Catalan Society of Gastroenterology.

    Science.gov (United States)

    García-Iglesias, Pilar; Botargues, Josep-Maria; Feu Caballé, Faust; Villanueva Sánchez, Càndid; Calvet Calvo, Xavier; Brullet Benedi, Enric; Cánovas Moreno, Gabriel; Fort Martorell, Esther; Gallach Montero, Marta; Gené Tous, Emili; Hidalgo Rosas, José-Manuel; Lago Macía, Amelia; Nieto Rodríguez, Ana; Papo Berger, Michel; Planella de Rubinat, Montserrat; Saló Rich, Joan; Campo Fernández de Los Ríos, Rafel

    2017-05-01

    In recent years there have been advances in the management of non-variceal upper gastrointestinal bleeding that have helped reduce rebleeding and mortality. This document positioning of the Catalan Society of Digestologia is an update of evidence-based recommendations on management of gastrointestinal bleeding peptic ulcer. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  17. X-ray optics and X-ray microscopes: new challenges

    International Nuclear Information System (INIS)

    Susini, J.

    2004-01-01

    Soon after the discovery of X-rays in 1895 by W. Roentgen, it became rapidly clear that the methods traditionally used in the visible light regime, namely refraction, diffraction and reflection were difficult to apply for X-ray optics. The physical origins of these difficulties are closely linked to the very nature of interaction of X-rays with matter. The small deviation δ of the refractive index of condensed matter from unity makes it difficult to extend refraction-based optics from the optical spectral region to the X-ray region because the refraction angle is proportional to δ. Similarly it is very challenging to extend diffraction-based focusing techniques to X-rays because the diffraction angle scales inversely with wavelength. Finally, the use of reflection-based optics is also limited by the very small critical angle for total reflection. All those fundamental limitations prevented for almost one century, the development of X-ray microscopy whereas electron microscopy became a standard tool. In the past twenty years, interests for X-ray microscopy revived, mainly because of several major advances in X-ray sources and X-ray optics. X-ray microscopy techniques are now emerging as powerful and complementary tools for submicron investigations. Soft X-ray microscopes offer traditionally the possibility to form direct images of thick hydrated biological material in near-native environment, at a spatial resolution well beyond that achievable with visible light microscopy. Natural contrast is available in the soft X-ray region, in the so-called ''water-window'', due to the presence of absorption edges of the major constituents (C,N,O). Recent advances in manufacturing techniques have enlarged the accessible energy range of micro-focussing optics and offer new applications in a broad range of disciplines. X-ray microscopy in the 1 - 30 keV energy range is better suited for fluorescence to map trace elements, tomography for 3D imaging and micro-diffraction. The

  18. X-ray geometrical smoothing effect in indirect x-ray-drive implosion

    International Nuclear Information System (INIS)

    Mochizuki, Takayasu; Sakabe, Shuji; Yamanaka, Chiyoe

    1983-01-01

    X-ray geometrical smoothing effect in indirect X-ray drive pellet implosion for inertial confinement fusion has been numerically analyzed. Attainable X-ray driven ablation pressure has been found to be coupled with X-ray irradiation uniformity. (author)

  19. Development of a prognostic nomogram for cirrhotic patients with upper gastrointestinal bleeding.

    Science.gov (United States)

    Zhou, Yu-Jie; Zheng, Ji-Na; Zhou, Yi-Fan; Han, Yi-Jing; Zou, Tian-Tian; Liu, Wen-Yue; Braddock, Martin; Shi, Ke-Qing; Wang, Xiao-Dong; Zheng, Ming-Hua

    2017-10-01

    Upper gastrointestinal bleeding (UGIB) is a complication with a high mortality rate in critically ill patients presenting with cirrhosis. Today, there exist few accurate scoring models specifically designed for mortality risk assessment in critically ill cirrhotic patients with upper gastrointestinal bleeding (CICGIB). Our aim was to develop and evaluate a novel nomogram-based model specific for CICGIB. Overall, 540 consecutive CICGIB patients were enrolled. On the basis of Cox regression analyses, the nomogram was constructed to estimate the probability of 30-day, 90-day, 270-day, and 1-year survival. An upper gastrointestinal bleeding-chronic liver failure-sequential organ failure assessment (UGIB-CLIF-SOFA) score was derived from the nomogram. Performance assessment and internal validation of the model were performed using Harrell's concordance index (C-index), calibration plot, and bootstrap sample procedures. UGIB-CLIF-SOFA was also compared with other prognostic models, such as CLIF-SOFA and model for end-stage liver disease, using C-indices. Eight independent factors derived from Cox analysis (including bilirubin, creatinine, international normalized ratio, sodium, albumin, mean artery pressure, vasopressin used, and hematocrit decrease>10%) were assembled into the nomogram and the UGIB-CLIF-SOFA score. The calibration plots showed optimal agreement between nomogram prediction and actual observation. The C-index of the nomogram using bootstrap (0.729; 95% confidence interval: 0.689-0.766) was higher than that of the other models for predicting survival of CICGIB. We have developed and internally validated a novel nomogram and an easy-to-use scoring system that accurately predicts the mortality probability of CICGIB on the basis of eight easy-to-obtain parameters. External validation is now warranted in future clinical studies.

  20. Recent Update of Embolization of Upper Gastrointestinal Tract Bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-02-15

    Nonvariceal upper gastrointestinal (UGI) bleeding is a frequent complication with significant morbidity and mortality. Although endoscopic hemostasis remains the initial treatment modality, severe bleeding despite endoscopic management occurs in 5-10% of patients, necessitating surgery or interventional embolotherapy. Endovascular embolotherapy is now considered the first-line therapy for massive UGI bleeding that is refractory to endoscopic management. Interventional radiologists need to be familiar with the choice of embolic materials, technical aspects of embolotherapy, and the factors affecting the favorable or unfavorable outcomes after embolotherapy for UGI bleeding.

  1. Different X-ray spectral evolution for black hole X-ray binaries in dual tracks of radio-X-ray correlation

    International Nuclear Information System (INIS)

    Cao, Xiao-Feng; Wu, Qingwen; Dong, Ai-Jun

    2014-01-01

    Recently, an 'outlier' track of radio-X-ray correlation was found, which is much steeper than the former universal correlation, where dual tracks were speculated to be triggered by different accretion processes. In this work, we test this issue by exploring hard X-ray spectral evolution in four black-hole X-ray binaries with multiple, quasi-simultaneous radio and X-ray observations. First, we find that hard X-ray photon indices, Γ, are negatively and positively correlated with X-ray fluxes when the X-ray flux, F 3-9 keV , is below and above a critical flux, F X, crit , which are consistent with predictions of the advection-dominated accretion flow and the disk-corona model, respectively. Second, and most importantly, we find that the radio-X-ray correlations are also clearly different when the X-ray fluxes are higher and lower than the critical flux as defined by X-ray spectral evolution. The data points with F 3-9 keV ≳ F X, crit have a steeper radio-X-ray correlation (F X ∝F R b and b ∼ 1.1-1.4), which roughly forms the ''outlier'' track. However, the data points with anti-correlation of Γ – F 3-9 keV either stay in the universal track with b ∼ 0.61 or stay in the transition track (from the universal to 'outlier' tracks or vice versa). Therefore, our results support that the universal and ''outlier'' tracks of radio-X-ray correlations are regulated by radiatively inefficient and radiatively efficient accretion model, respectively.

  2. Comparison of x-ray output of inverter-type x-ray equipment

    International Nuclear Information System (INIS)

    Asano, Hiroshi; Miyake, Hiroyuki; Yamamoto, Keiichi

    2000-01-01

    The x-ray output of 54 inverter-type x-ray apparatuses used at 18 institutions was investigated. The reproducibility and linearity of x-ray output and variations among the x-ray equipment were evaluated using the same fluorescence meter. In addition, the x-ray apparatuses were re-measured using the same non-invasive instrument to check for variations in tube voltage, tube current, and irradiation time. The non-invasive instrument was calibrated by simultaneously obtaining measurements with an invasive instrument, employing the tube voltage and current used for the invasive instrument, and the difference was calculated. Reproducibility of x-ray output was satisfactory for all x-ray apparatuses. The coefficient of variation was 0.04 or less for irradiation times of 5 ms or longer. In 84.3% of all x-ray equipment, variation in the linearity of x-ray output was 15% or less for an irradiation time of 5 ms. However, for all the apparatuses, the figure was 50% when irradiation time was the shortest (1 to 3 ms). Variation in x-ray output increased as irradiation time decreased. Variation in x-ray output ranged between 1.8 and 2.5 compared with the maximum and minimum values, excluding those obtained at the shortest irradiation time. The relative standard deviation ranged from ±15.5% to ±21.0%. The largest variation in x-ray output was confirmed in regions irradiated for the shortest time, with smaller variations observed for longer irradiation times. The major factor responsible for variation in x-ray output in regions irradiated for 10 ms or longer, which is a relatively long irradiation time, was variation in tube current. Variation in tube current was slightly greater than 30% at maximum, with an average value of 7% compared with the preset tube current. Variations in x-ray output in regions irradiated for the shortest time were due to photographic effects related to the rise and fall times of the tube voltage waveform. Accordingly, in order to obtain constant x-ray

  3. X-ray polarimetry. [aboard Ariel 5 and OSO 8 for observation of galactic sources

    Science.gov (United States)

    Long, K. S.; Chanan, G. A.; Helfand, D. J.; Ku, W. H.-M.; Novick, R.

    1979-01-01

    The method by which the Bragg-crystal X-ray polarimeters aboard Ariel 5 and OSO 8 operate is briefly described, and some results obtained with these instruments for six Galactic X-ray sources are summarized. A precision measurement of the linear polarization in the Crab Nebula at energies of 2.6 and 5.2 keV is presented. Evidence is given for polarization in Sco X-1, Cyg X-2, Cen X-3, and the X-ray transient A0620-00. The determined or estimated polarizations are approximately 19.2% at 2.6 keV and 19.5% at 5.2 keV for the Crab Nebula, 1.1% at 2.6 keV and 2.4% at 5.2 keV for Sco X-1, 2.5% at 2.6 keV and 9.8% at 5.2 keV for Cyg X-1, an upper limit of 13.5% for A0620-00, an upper limit of 13.5% to the time-averaged polarization of Cen X-3, and an apparent value of about 5% for Cyg X-2.

  4. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  5. Differential X-ray diagnosis of disseminated pulmonary tuberculosis and certain collagenoses

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, V.A. (Sverdlovskij Meditsinskij Inst. (USSR))

    X-ray picture has been analysed in patients of 2 groups. The 1st group included 120 patients with disseminated tuberculosis, the 2 nd one 56 patients with systemic diseases (lupus erythematosus and scleroderma). The disease initial diagnosis was erroneous in 8 cases (4.5%), i.e. in 5 patients tuberculosis was unrecognized, and in 3 the systemic disease. It is marked, that x-ray pulmonary alterations bore interstitial character in collagenoses, and focal in tuberculosis. Predominant apical posterior lung segment lesion was detected in 95% of cases in tuberculosis, while caverns were diagnosed in 65.8%. Besides, radiographic features of the gastrointestinal tract, the skeleton, and the heart damage were established in 82.9% of systemic scleroderma patients.

  6. X-ray spectroscopy of kaonic atoms at SIDDHARTA

    Directory of Open Access Journals (Sweden)

    Cargnelli M.

    2014-06-01

    Full Text Available The X-ray measurements of kaonic atoms play an important role for understanding the low-energy QCD in the strangeness sector. The SIDDHARTA experiment studied the X-ray transitions of 4 light kaonic atoms (H, D, 3He, and 4He using the DAFNE electron-positron collider at LNF (Italy. Most precise values of the shift and width of the kaonic hydrogen 1s state were determined, which have been now used as fundamental information for the low-energy K−p interaction in theoretical studies. An upper limit of the X-ray yield of kaonic deuterium was derived, important for future K−d experiments. The shifts and widths of the kaonic 3He and 4He 2p states were obtained, confirming the end of the “kaonic helium puzzle”. In this contribution also the plans for new experiments of kaonic deuterium are being presented.

  7. Wide field X-ray telescopes: Detecting X-ray transients/afterglows related to gamma ray bursts

    International Nuclear Information System (INIS)

    Hudec, Rene; Pina, Ladislav; Inneman, Adolf; Gorenstein, Paul; Rezek, Tomas

    1999-01-01

    The recent discovery of X-ray afterglows of GRBs opens the possibility of analyses of GRBs by their X-ray detections. However, imaging X-ray telescopes in current use mostly have limited field of view. Alternative X-ray optics geometries achieving very large fields of view have been theoretically suggested in the 70ies but not constructed and used so far. We review the geometries and basic properties of the wide-field X-ray optical systems based on one- and two-dimensional lobster-eye geometry and suggest technologies for their development and construction. First results of the development of double replicated X-ray reflecting flats for use in one-dimensional X-ray optics of lobster eye type are presented and discussed. Optimum strategy for locating GRBs upon their X-ray counterparts is also presented and discussed

  8. Embolization for non-variceal upper gastrointestinal tract haemorrhage: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Mirsadraee, S.; Tirukonda, P.; Nicholson, A. [Department of Radiology, Leeds General Infirmary, Leeds (United Kingdom); Everett, S.M. [Department of Gastroenterology, Leeds General Infirmary, Leeds (United Kingdom); McPherson, S.J., E-mail: simon.mcpherson@leedsth.nhs.u [Department of Radiology, Leeds General Infirmary, Leeds (United Kingdom)

    2011-06-15

    Aim: To assess the published evidence on the endovascular treatment of non-variceal upper gastrointestinal haemorrhage. Materials and methods: An Ovid Medline search of published literature was performed (1966-2009). Non-English literature, experimental studies, variceal haemorrhage and case series with fewer than five patients were excluded. The search yielded 1888 abstracts. Thirty-five articles were selected for final analysis. Results: The total number of pooled patients was 927. The technical and clinical success of embolization ranged from 52-100% and 44-100%, respectively. The pooled mean technical/clinical success rate in primary upper gastrointestinal tract haemorrhage (PUGITH) only, trans-papillary haemorrhage (TPH) only, and mixed studies were 84%/67%, 93%/89%, and 93%/64%, respectively. Clinical outcome was adversely affected by multi-organ failure, shock, corticosteroids, transfusion, and coagulopathy. The anatomical source of haemorrhage and procedural variables did not affect the outcome. A successful embolization improved survival by 13.3 times. Retrospective comparison with surgery demonstrated equivalent mortality and clinical success, despite embolization being applied to a more elderly population with a higher prevalence of co-morbidities. Conclusions: Embolization is effective in this very difficult cohort of patients with outcomes similar to surgery.

  9. X-ray bursts observed with JEM-X

    DEFF Research Database (Denmark)

    Brandt, Søren Kristian; Chenevez, Jérôme; Lund, Niels

    2006-01-01

    We report on the search for X-ray bursts in the JEM-X X-ray monitor on INTEGRAL during the first two years of operations. More than 350 bursts from 25 different type-I X-ray burst sources were found.......We report on the search for X-ray bursts in the JEM-X X-ray monitor on INTEGRAL during the first two years of operations. More than 350 bursts from 25 different type-I X-ray burst sources were found....

  10. X-Ray and Near-Infrared Spectroscopy of Dim X-Ray Point Sources Constituting the Galactic Ridge X-Ray Emission

    Directory of Open Access Journals (Sweden)

    Kumiko Morihana

    2014-12-01

    Full Text Available We present the results of X-ray and Near-Infrared observations of the Galactic Ridge X-ray Emission (GRXE. We extracted 2,002 X-ray point sources in the Chandra Bulge Field (l =0°.113, b = 1°.424 down to ~10-14.8 ergscm-2s-1 in 2-8 keV band with the longest observation (900 ks of the GRXE. Based on X-ray brightness and hardness, we classied the X-ray point sources into three groups: A (hard, B (soft and broad spectrum, and C (soft and peaked spectrum. In order to know populations of the X-ray point sources, we carried out NIR imaging and spectroscopy observation. We identied 11% of X-ray point sources with NIR and extracted NIR spectra for some of them. Based on X-ray and NIR properties, we concluded that non-thermal sources in the group A are mostly active galactic nuclei and the thermal sources are mostly white dwarf binaries such as cataclysmic variables (CVs and Pre-CVs. We concluded that the group B and C sources are X-ray active stars in flare and quiescence, respectively.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  13. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  14. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  15. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  16. Acute upper gastrointestinal bleeding in the Amsterdam area: incidence, diagnosis, and clinical outcome

    NARCIS (Netherlands)

    Vreeburg, E. M.; Snel, P.; de Bruijne, J. W.; Bartelsman, J. F.; Rauws, E. A.; Tytgat, G. N.

    1997-01-01

    In the United States of America and the United Kingdom several epidemiological upper gastrointestinal bleeding (UGIB) surveys have been done. However, information about the current epidemiology of acute UGIB in continental Western Europe is sparse. From July of 1993 to July of 1994, 951 patients

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  18. Novel X-ray telescopes for wide-field X-ray monitoring

    International Nuclear Information System (INIS)

    Hudec, R.; Inneman, A.; Pina, L.; Sveda, L.

    2005-01-01

    We report on fully innovative very wide-field of view X-ray telescopes with high sensitivity as well as large field of view. The prototypes are very promising, allowing the proposals for space projects with very wide-field Lobster-eye X-ray optics to be considered. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study and to understand various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. The Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  20. Perfect-crystal x-ray optics to treat x-ray coherence

    International Nuclear Information System (INIS)

    Yamazaki, Hiroshi; Ishikawa, Tetsuya

    2007-01-01

    X-ray diffraction of perfect crystals, which serve as x-ray monochromator and collimator, modifies coherence properties of x-ray beams. From the time-dependent Takagi-Taupin equations that x-ray wavefields obey in crystals, the reflected wavefield is formulated as an integral transform of a general incident wavefield with temporal and spatial inhomogeneity. A reformulation of rocking-curve profiles from the field solution of the Takagi-Taupin equations allows experimental evaluation of the mutual coherence function of x-ray beam. The rigorous relationship of the coherence functions between before and after reflection clarifies how the coherence is transferred by a crystal. These results will be beneficial to developers of beamline optics for the next generation synchrotron sources. (author)

  1. X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation

    International Nuclear Information System (INIS)

    Hodoroaba, V.-D.; Radtke, M.; Vincze, L.; Rackwitz, V.; Reuter, D.

    2010-01-01

    X-ray scattering may contribute significantly to the spectral background of X-ray fluorescence (XRF) spectra. Based on metrological measurements carried out with a scanning electron microscope (SEM) having attached a well characterised X-ray source (polychromatic X-ray tube) and a calibrated energy dispersive X-ray spectrometer (EDS) the accuracy of a physical model for X-ray scattering is systematically evaluated for representative samples. The knowledge of the X-ray spectrometer efficiency, but also of the spectrometer response functions makes it possible to define a physical spectral background of XRF spectra. Background subtraction relying on purely mathematical procedures is state-of-the-art. The results produced by the analytical model are at least as reliable as those obtained by Monte-Carlo simulations, even without considering the very challenging contribution of multiple scattering. Special attention has been paid to Compton broadening. Relevant applications of the implementation of the analytical model presented in this paper are the prediction of the limits of detection for particular cases or the determination of the transmission of X-ray polycapillary lenses.

  2. X-Ray Scattering Applications Using Pulsed X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Larson, B.C.

    1999-05-23

    Pulsed x-ray sources have been used in transient structural phenomena investigations for over fifty years; however, until the advent of synchrotrons sources and the development of table-top picosecond lasers, general access to ligh temporal resolution x-ray diffraction was relatively limited. Advances in diffraction techniques, sample excitation schemes, and detector systems, in addition to IncEased access to pulsed sources, have ld tO what is now a diverse and growing array of pulsed-source measurement applications. A survey of time-resolved investigations using pulsed x-ray sources is presented and research opportunities using both present and planned pulsed x-ray sources are discussed.

  3. X-ray diagnostic installation for X-ray tomographic images

    International Nuclear Information System (INIS)

    Haendle, J.; Sklebitz, H.

    1984-01-01

    An exemplary embodiment includes at least one x-ray tube for the generation of an x-ray beam, a patient support, an image detector, and a control generator-connected with the x-ray tube and the image detector-for the purpose of moving the x-ray beam, and in opposition thereto, the image field of the image detector. There is connected to the control generator a layer height computer which calculates the enlargement from the geometric data for the tomogram. The image detector has a circuit-connected with the layer height computer-for the purpose of fading-in a marking for the dimensions in the layer plane

  4. Sex differences in dreaming during short propofol sedation for upper gastrointestinal endoscopy.

    Science.gov (United States)

    Xu, Guanghong; Liu, Xuesheng; Sheng, Qiying; Yu, Fengqiong; Wang, Kai

    2013-10-02

    Previous reports suggest that sex differences may exist in dreaming under anesthesia, but their results were inconclusive. The current study explored sex differences in the incidence and content of dreams during short propofol sedation for upper gastrointestinal endoscopy and investigated whether sex differences or dream content affect patient satisfaction with sedation. A total of 200 patients (100 men and 100 women) undergoing upper gastrointestinal endoscopy participated in this study. Patients were interviewed with the modified Brice questionnaire about the incidence and the content of dreams, and satisfaction with sedation was assessed. The results showed that the incidence of dreaming was significantly higher in men (31%) than in women (17%) (P=0.02), but recovery time was similar. In men, 45% (14/31) of dreamers reported positive emotional content and only 6% (2/31) reported negative emotional content. In contrast, in women, 18% (3/17) reported positive and 29% (5/17) reported negative content (P=0.04). Men reported dreams that were more vivid, meaningful, familiar, and memorable (PDreamer satisfaction with sedation was not influenced by sex or dream content.

  5. Upper gastrointestinal bleeding in a patient with depression receiving selective serotonin reuptake inhibitor therapy.

    Science.gov (United States)

    Kumar, Deepak; Saaraswat, Tanuj; Sengupta, S N; Mehrotra, Saurabh

    2009-02-01

    Serotonin plays an important role in the normal clotting phenomenon and is released by platelets. Platelets are dependent on a serotonin transporter for the uptake of serotonin, as they cannot synthesize it themselves. Selective serotonin reuptake inhibitors (SSRIs) block the uptake of serotonin into platelets and can cause problems with clotting leading to bleeding. This case report highlights the occurrence of upper gastrointestinal bleeding in the index case on initiating SSRI therapy for depression and the prompt resolution of the same on its discontinuation on two separate occasions. SSRIs may cause upper gastrointestinal (GI) bleeding. Physicians should be aware of the same and should try to rule out previous episodes of upper GI bleed or the presence of other risk factors which might predispose to it before prescribing SSRIs; they should also warn the patients about this potential side effect. Also, the presence of thalassemia trait in the index patient deserves special attention and needs to be explored to see if it might in any way contribute in potentiating this side effect of SSRIs.

  6. X-ray emission spectroscopy. X-ray fluorescence

    International Nuclear Information System (INIS)

    Despujols, J.

    1992-01-01

    Principles of X-ray emission spectrometry are first recalled, then wave-length dispersive and energy dispersive X-ray fluorescence spectrometer are described. They are essentially designed for qualitative and quantitative analysis of elements (Z>10). Sample preparation, calibration, corrections, interferences, accuracy are reviewed. Examples of use in different industries are given. (71 refs.)

  7. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  8. X-ray detector for a panoramic X-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Cowell, D; Ensslin, F H

    1976-01-15

    The discovery deals with an X-ray detector suitable for the controlling of panoramic X-ray systems. It consists of a fluorescent image screen and a semiconductor photo cell. The output signal of the detector is proportional to the intensity of the X-radiation and the response time is large enough to follow the change of amplitude of the contours of the modulated X radiation. The detector with band-pass filter regulates, via a control system, the moving rate of the X-ray source and of the film opposite it in dependence of the intensity, so that a uniform exposure is ensured.

  9. Guidelines for endoscopic management of non-variceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Fujishiro, Mitsuhiro; Iguchi, Mikitaka; Kakushima, Naomi; Kato, Motohiko; Sakata, Yasuhisa; Hoteya, Shu; Kataoka, Mikinori; Shimaoka, Shunji; Yahagi, Naohisa; Fujimoto, Kazuma

    2016-05-01

    Japan Gastroenterological Endoscopy Society (JGES) has compiled a set of guidelines for endoscopic management of non-variceal upper gastrointestinal bleeding using evidence-based methods. The major cause of non-variceal upper gastrointestinal bleeding is peptic gastroduodenal ulcer bleeding. As a result, these guidelines mainly focus on peptic gastroduodenal ulcer bleeding, although bleeding from other causes is also overviewed. From the epidemiological aspect, in recent years in Japan, bleeding from drug-related ulcers has become predominant in comparison with bleeding from Helicobacter pylori (HP)-related ulcers, owing to an increase in the aging population and coverage of HP eradication therapy by national health insurance. As for treatment, endoscopic hemostasis, in which there are a variety of methods, is considered to be the first-line treatment for bleeding from almost all causes. It is very important to precisely evaluate the severity of the patient's condition and stabilize the patient's vital signs with intensive care for successful endoscopic hemostasis. Additionally, use of antisecretory agents is recommended to prevent rebleeding after endoscopic hemostasis, especially for gastroduodenal ulcer bleeding. Eighteen statements with evidence and recommendation levels have been made by the JGES committee of these guidelines according to evidence obtained from clinical research studies. However, some of the statements that are supported by a low level of evidence must be confirmed by further clinical research. © 2016 Japan Gastroenterological Endoscopy Society.

  10. X-ray imaging with compound refractive lens and microfocus X-ray tube

    OpenAIRE

    Pina, Ladislav; Dudchik, Yury; Jelinek, Vaclav; Sveda, Libor; Marsik, Jiri; Horvath, Martin; Petr, Ondrej

    2008-01-01

    Compound refractive lenses (CRL), consisting of a lot number in-line concave microlenses made of low-Z material were studied. Lenses with focal length 109 mm and 41 mm for 8-keV X-rays, microfocus X-ray tube and X-ray CCD camera were used in experiments. Obtained images show intensity distribution of magnified microfocus X-ray source focal spot. Within the experiments, one lens was also used as an objective lens of the X-ray microscope, where the copper anode X-ray microfocus tube served as a...

  11. Unusual Upper Gastrointestinal Bleeding due to Late Metastasis from Renal Cell Carcinoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Wen-Tsan Chang

    2004-03-01

    Full Text Available A case of recurrent massive upper gastrointestinal bleeding originating from metastatic renal cell carcinoma is reported. A 63-year-old woman underwent right nephrectomy 9 years previously and experienced no recurrence during follow-up. A gradually enlarging ulcerative tumor over the bulb of the duodenum and four subsequent episodes of massive bleeding from this tumor occurred between June 2001 and March 2002. The patient underwent surgery in April 2002 for intractable bleeding from the tumor. Renal cell carcinoma metastasis to the duodenum was confirmed from the surgical specimen. Upper gastrointestinal bleeding due to malignancy is very rare and the duodenum is the least frequently involved site. Furthermore, a solitary late renal cell carcinoma metastasis 9 years after a nephrectomy is extremely uncommon. This case suggests that life-long follow-up of renal cell carcinoma patients is necessary, owing to unpredictable behavior and the possibility of long disease-free intervals. In nephrectomized patients suffering from gastrointestinal bleeding, complete evaluation, especially endoscopic examination, is indicated. The possibility of late recurrent renal cell carcinoma metastasis to the gastrointestinal tract should be kept in mind, although it is rare. If the patient is fit for surgery, metastatectomy is the first choice of treatment.

  12. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  13. Frequency of peptic ulcer disease in patients of dyspepsia an analysis of upper gastrointestinal endoscopy

    International Nuclear Information System (INIS)

    Anwar, S.O.; Ambreen, S.; Ashraf, H.M.

    2010-01-01

    To evaluate the frequency of peptic ulcer disease in patients of dyspepsia on upper gastrointestinal endoscopy. A convenient non probability sampling was done and one hundred patients were selected from out patient department presenting within six months of dyspeptic symptoms. They were all subjected to upper gastrointestinal endoscopy Of all patients 61% (n=61) were males and 39% (n=39) were females with age ranging between 20 - 45 years. Study revealed functional dyspepsia (76%), duodenal ulcer (11%), gastric ulcer (4%) and esophagitis including gastoesophageal reflux disease (9%). This showed an overall frequency of peptic ulcer disease to be 15% in the studied population.Conclusion: Peptic ulcer disease is a common structural cause of dyspepsia and was responsible for 15% of dyspepsia. (author)

  14. Results of a second questionnaire on pediatric X-ray examinations

    International Nuclear Information System (INIS)

    Ishikawa, Mitsuo; Kubota, Katsumi

    1999-01-01

    Radiographic conditions (x-ray tube voltage, irradiation time, etc.) differ among medical facilities. A second questionnaires was sent out to determine the current state of pediatric radiography and eventually provide reference materials for the standardization of radiographic parameters used in pediatric x-ray examinations. The questionnaire, which was sent in 1996, targeted 161 facilities that belong to the Society for Pediatric Radiological Technology. The objects of examination were the chest, upper airway, abdomen, hip joint, skull, and knee joint. The questionnaire investigated age (children of six months, three years, and seven years), type of x-ray generator, radiographic conditions, etc. Moreover, this time the items head x-ray computed tomography (X-CT) and abdominal X-CT were added. Completed questionnaires were received from 79 facilities, for a recovery of 49.1%. Compared with the previous investigation, inverter-type high-voltage assemblies increased, whereas twelve-peak high-voltage assemblies decreased. The focal spot of the x-ray tube assembly was smaller, and maximum anode heat content had increased. CR systems and green luminescence-orthochromatic systems were increasingly being used as image receptors. Advances in x-ray generators and the image receptor systems created reductions in the time required for radiography, which was possible at as short a time as 1 msec. Moreover, image quality was also improved by these advances. However, no major changes were observed in the conditions of radiography. (author)

  15. X-ray spectroscopy and X-ray crystallography of metalloenzymes at XFELs

    International Nuclear Information System (INIS)

    Yano, Junko

    2016-01-01

    The ultra-bright femtosecond X-ray pulses provided by X-ray Free Electron Lasers (XFELs) open capabilities for studying the structure and dynamics of a wide variety of biological and inorganic systems beyond what is possible at synchrotron sources. Although the structure and chemistry at the catalytic sites have been studied intensively in both biological and inorganic systems, a full understanding of the atomic-scale chemistry requires new approaches beyond the steady state X-ray crystallography and X-ray spectroscopy at cryogenic temperatures. Following the dynamic changes in the geometric and electronic structure at ambient conditions, while overcoming X-ray damage to the redox active catalytic center, is key for deriving reaction mechanisms. Such studies become possible by using the intense and ultra-short femtosecond X-ray pulses from an XFEL, where sample is probed before it is damaged. We have developed methodology for simultaneously collecting crystallography data and X-ray emission spectra, using an energy dispersive spectrometer at ambient conditions. In addition, we have developed a way to collect metal L-edge data of dilute samples using soft X-rays at XFELs. The advantages and challenges of these methods will be described in this review. (author)

  16. ENDOSCOPIC DIAGNOSIS AND TREATMENT OF UPPER GASTROINTESTINAL BLEEDING

    Directory of Open Access Journals (Sweden)

    Daniela Benedeto-Stojanov

    2015-06-01

    Full Text Available Upper gastrointestinal bleeding (UGB is a common medical emergency problem with significant morbidity and mortality. The aim of this paper is to establish the incidence of upper gastrointestinal bleeding in relation to sex and age, determine the prevalence of bleeding lesions and perform analysis of bleeding peptic ulcer in relation to the location, age, gender, Forrest classification and the need for endoscopic hemostasis. Thе prospective study included 70 patients with UGB, 42 men and 28 women, mean age 68.64±13.66 years. The diagnosis of bleeding lesions was made exclusively by means of esophagogastroduodenoscopy. Forrest classification was used in the evaluation of the activity of bleeding ulcers of the stomach and duodenum. The largest number of bleeding patients was of male sex (60%. Bleeding most commonly occurred in patients older than 60 years (84.29%. Statistically, female patients were significantly older than patients of male gender (p=0.001. The most common cause of bleeding was peptic ulcer (65.71%. The average age of patients with gastric ulcer was 70.57±15.68 years, with a duodenal ulcer 63.78±16.70 years. In the duodenum, Forrest Ib, IIa and IIb ulcers were usually confirmed, whereas Forrest IIc ulcers were identified in the stomach. Endoscopic hemostasis was required in 55.56% of patients with duodenal and in 23.81% of patients with gastric ulcer. The incidence of UGB is higher in men and it increases with age. The most common cause of bleeding is ulcer disease. Patients with gastric ulcer are older than patients with duodenal ulcer, while both gastric and duodenal ulcers are found in the oldest patients. Duodenal ulcers cause serious bleeding and more often require endoscopic hemostasis.

  17. Differential X-ray diagnosis of disseminated pulmonary tuberculosis and certain collagenoses

    International Nuclear Information System (INIS)

    Sokolov, V.A.

    1982-01-01

    X-ray picture has been analysed in patients of 2 groups. The 1st group included 120 patients with disseminated tuberculosis, the 2 nd one 56 patients with systemic diseases (lupus erythematosus and scleroderma). The disease initial diagnosis was erroneous in 8 cases (4.5%), i.e. in 5 patients tuberculosis was unrecognized, and in 3 the systemic disease. It is marked, that x-ray pulmonary alterations bore interstitial character in collagenoses, and focal in tuberculosis. Predominant apical posterior lung segment lesion was detected in 95% of cases in tuberculosis, while caverns were diagnosed in 65.8%. Besides, radiographic features of the gastrointestinal tract, the skeleton, and the heart damage were established in 82.9% of systemic scleroderma patients [ru

  18. Development of optimal management of upper gastrointestinal bleeding secondary to pancreatic sinistral portal hypertension

    Directory of Open Access Journals (Sweden)

    SONG Yang

    2014-08-01

    Full Text Available The pathogenesis of pancreatic sinistral portal hypertension (PSPH is quite different from that of cirrhotic portal hypertension, and PSPH is the only curable type of portal hypertension. Gastric variceal bleeding is a less common manifestation of PSPH; however, it probably exacerbates the patient’s condition and leads to critical illness, and inappropriate management would result in death. Therefore, it is necessary to develop the optimal management of upper gastrointestinal bleeding in PSPH patients. Splenectomy is considered as a definitive procedure, together with surgical procedures to treat underlying pancreatic diseases. For patients in poor conditions or ineligible for surgery, splenic artery coil embolization is a preferable and effective method to stop bleeding before second-stage operation. The therapeutic decision should be made individually, and the further multi-center study to optimize the management of upper gastrointestinal bleeding from PSPH is warranted.

  19. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  20. Modern X-ray spectroscopy 3. X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Hayashi, Kouichi

    2008-01-01

    X-ray fluorescence holography (XFH) provides three dimensional atomic images around specified elements. The XFH uses atoms as a wave source or monitor of interference field within a crystal sample, and therefore it can record both intensity and phase of scattered X-rays. Its current performance makes it possible to apply to ultra thin film, impurity and quasicrystal. In this article, I show the theory including solutions for twin image problem, advanced measuring system, data processing for reconstruction of the atomic images and for obtaining accurate atomic positions, applications using resonant X-ray scattering and X-ray excited optical luminescence, and an example of XFH result on the local structure around copper in silicon steal. (author)

  1. X-ray holography: X-ray interactions and their effects

    International Nuclear Information System (INIS)

    London, R.A.; Trebes, J.E.; Rosen, M.D.

    1988-01-01

    The authors summarize a theoretical study of the interactions of x-rays with a biological sample during the creation of a hologram. The choice of an optimal wavelength for x-ray holography is discussed, based on a description of scattering by objects within an aqueous environment. The problem of the motion resulting from the absorption of x-rays during a short exposure is described. The possibility of using very short exposures in order to capture the image before motion can compromise the resolution is explored. The impact of these calculation on the question of the feasibility of using an x-ray laser for holography of biological structures is discussed. 12 refs., 2 figs

  2. Reduced hemoglobin and increased C-reactive protein are associated with upper gastrointestinal bleeding.

    Science.gov (United States)

    Tomizawa, Minoru; Shinozaki, Fuminobu; Hasegawa, Rumiko; Togawa, Akira; Shirai, Yoshinori; Ichiki, Noboru; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Sueishi, Makoto

    2014-02-07

    To investigate the early upper gastrointestinal endoscopy (endoscopy) significantly reduces mortality resulting from upper gastrointestinal (GI) bleeding. Upper GI bleeding was defined as 1a, 1b, 2a, and 2b according to the Forrest classification. The hemoglobin (Hb), and C-reactive protein (CRP) were examined at around the day of endoscopy and 3 mo prior to endoscopy. The rate of change was calculated as follows: (the result of blood examination on the day of endoscopy - the results of blood examination 3 mo prior to endoscopy)/(results of blood examination 3 mo prior to endoscopy). Receiver operating characteristic curves were created to determine threshold values. Seventy-nine men and 77 women were enrolled. There were 17 patients with upper GI bleeding: 12 with a gastric ulcer, 3 with a duodenal ulcer, 1 with an acute gastric mucosal lesion, and 1 with gastric cancer. The area under the curve (AUC), threshold, sensitivity, and specificity of Hb around the day of endoscopy were 0.902, 11.7 g/dL, 94.1%, and 77.1%, respectively, while those of CRP were 0.722, 0.5 mg/dL, 70.5%, and 73%, respectively. The AUC, threshold, sensitivity, and specificity of the rate of change of Hb were 0.851, -21.3%, 76.4%, and 82.6%, respectively, while those of CRP were 0.901, 100%, 100%, and 82.5%, respectively. Predictors for upper GI bleeding were Hb 21.3% and an increase in the CRP > 100%, 3 mo before endoscopy.

  3. Development of confocal micro X-ray fluorescence instrument using two X-ray beams

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Nakano, Kazuhiko; Ding Xunliang

    2007-01-01

    A new confocal micro X-ray fluorescence instrument was developed. This instrument has two independent micro X-ray tubes with Mo targets. A full polycapillary X-ray lens was attached to each X-ray tube. Another half polycapillary lens was attached to a silicon drift X-ray detector (SDD). The focal spots of the three lenses were adjusted to a common position. The effects of the excitation of two X-ray beams were investigated. The instrument enabled highly sensitive three-dimensional X-ray fluorescence analysis. We confirmed that the X-ray fluorescence intensity from the sample increased by applying the two independent X-ray tubes in confocal configuration. Elemental depth profiling of black wheat was demonstrated with the result that each element in the surface coat of a wheat grain showed unique distribution

  4. Modern X-ray difraction. X-ray diffractometry for material scientists, physicists, and chemicists

    International Nuclear Information System (INIS)

    Spiess, L.; Schwarzer, R.; Behnken, H.; Teichert, G.

    2005-01-01

    The book yields a comprehensive survey over the applications of X-ray diffraction in fields like material techniques, metallurgy, electrotechniques, machine engineering, as well as micro- and nanotechniques. The necessary fundamental knowledge on X-ray diffraction are mediated foundedly and illustratively. Thereby new techniques and evaluation procedures are presented as well as well known methods. The content: Production and properties of X radiation, diffraction of X radiation, hardware for X-ray diffraction, methods of X-ray diffraction, lattice-constant determination, phase analysis, X-ray profile analysis, crystal structure analysis, X-ray radiographic stress analysis, X-ray radiographic texture analysis, crystal orientation determination, pecularities at thin films, small angle scattering

  5. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  6. Evaluation of patient doses from upper gastrointestinal tract examinations based on the dosimetry in an anthropomorphic phantom

    International Nuclear Information System (INIS)

    Hirofuji, Yoshiaki; Aoyama, Takahiko; Koyama, Shuji; Kawaura, Chiyo

    2005-01-01

    The objective of this study was to evaluate organ dose and effective dose to patients from examinations of the upper gastrointestinal (GI) tract. Absorbed doses of various tissues and organs were measured using novel photodiode dosimeters installed in an anthropomorphic phantom representing a standard Japanese adult body. The organ dose and the effective dose were assessed from the absorbed doses according to the definitions seen in the publications of the International Commission on Radiological Protection. Dose measurements were performed for each projection of the upper GI tract examination in seven procedures at four hospitals and in a mobile coach, and organ and effective doses were assessed for each procedure. Organ doses obtained in the observation areas such as the stomach, esophagus and colon were in the order of several to more than 60 mGy, though they decreased to less than 1 mGy for tissues and organs distant from the observation areas. Organ doses and effective doses differed largely according to tube voltage, filtration and tube current or mAs value of the x-ray generator used, and by examination protocol, number of images, fluoroscopy time, and imaging units such as screen/film, computed radiography, digital radiography and flat panel detector. The number of images and the fluoroscopy time were 7 and 1.5 min for the examination in the mobile coach, and 18-22 and 2-6 min in the hospitals. Evaluated effective dose for the examination in the mobile coach was 2.9 mSv, and that in the hospitals ranged from 4.0-13.4 mSv at a ratio of more than three. (author)

  7. X-ray scattering measurements from thin-foil x-ray mirrors

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; BYRNAK, BP; Hornstrup, Allan

    1992-01-01

    Thin foil X-ray mirrors are to be used as the reflecting elements in the telescopes of the X-ray satellites Spectrum-X-Gamma (SRG) and ASTRO-D. High resolution X-ray scattering measurements from the Au coated and dip-lacquered Al foils are presented. These were obtained from SRG mirrors positioned...... in a test quadrant of the telescope structure and from ASTRO-D foils held in a simple fixture. The X-ray data is compared with laser data and other surface structure data such as STM, atomic force microscopy (AFM), TEM, and electron micrography. The data obtained at Cu K-alpha(1), (8.05 keV) from all...

  8. X-ray examination apparatus

    NARCIS (Netherlands)

    2000-01-01

    The invention relates to an X-ray apparatus which includes an adjustable X-ray filter. In order to adjust an intensity profile of the X-ray beam, an X-ray absorbing liquid is transported to filter elements of the X-ray filter. Such transport is susceptible to gravitational forces which lead to an

  9. Development of x-ray laminography under an x-ray microscopic condition

    International Nuclear Information System (INIS)

    Hoshino, Masato; Uesugi, Kentaro; Takeuchi, Akihisa; Suzuki, Yoshio; Yagi, Naoto

    2011-01-01

    An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatial resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique.

  10. Hard X-ray Flux from Low-Mass Stars in the Cygnus OB2 Association

    Science.gov (United States)

    Caramazza, M.; Drake, J. J.; Micela, G.; Flaccomio, E.

    2009-05-01

    We investigate the X-ray emission in the 20-40 keV band expected from the flaring low-mass stellar population in Cygnus OB2 assuming that the observed soft X-ray emission is due to a superposition of flares and that the ratio of hard X-ray to soft X-ray emission is described by a scaling found for solar flares by Isola and co-workers. We estimate a low-mass stellar hard X-ray flux in the 20-40 keV band in the range ~7×1031-7×1033 erg/s and speculate the limit of this values. Hard X-ray emission could lie at a level not much below the current observed flux upper limits for Cygnus OB2. Simbol-X, with its broad energy band (10-100 keV) and its sensitivity should be able to detect this emission and would provide insights into the hard X-ray production of flares on pre-main sequence stars.

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  12. OSO-7 observations of high galactic latitude x-ray sources

    International Nuclear Information System (INIS)

    Markert, T.H.; Canizares, C.R.; Clark, G.W.; Li, F.K.; Northridge, P.L.; Sprott, G.F.; Wargo, G.F.

    1976-01-01

    Six hundred days of observations by the MIT X-ray detectors aboard OSO-7 have been analyzed. All-sky maps of X-ray intensity have been constructed from these data. A sample map is displayed. Seven sources with galactic latitude vertical-barb/subi//subi/vertical-bar>10degree, discovered during the mapping process, are reported, and upper limits are set on other high-latitude sources. The OSO-7 results are compared with those of Uhuru and an implication of this comparison, that many of the high-latitude sources may be variable, is discussed

  13. Phase II trial of erlotinib and bevacizumab in patients with advanced upper gastrointestinal cancers

    DEFF Research Database (Denmark)

    Rohrberg, Kristoffer S; Olesen, René K; Pfeiffer, Per

    2012-01-01

    Patients with upper gastrointestinal cancers have a poor prognosis and only few treatment options. The epidermal growth factor receptor (EGFR) and vascular endothelial growth factor (VEGF) are valid targets in many solid tumours, and they have synergistic effects in preclinical studies....

  14. Upper Gastrointestinal Function in Morbidly Obese Adolescents Before and 6 Months After Gastric Banding

    NARCIS (Netherlands)

    Singendonk, M.; Kritas, S.; Omari, T.; Feinle-Bisset, C.; Page, A. J.; Frisby, C. L.; Kentish, S. J.; Ferris, L.; McCall, L.; Kow, L.; Chisholm, J.; Khurana, S.

    2017-01-01

    The effects of laparoscopic adjustable gastric band (LAGB) placement on upper gastrointestinal tract function in obese adolescents are unknown. Therefore, our aim was to determine the short-term effects of LAGB on esophageal motility, gastroesophageal reflux, gastric emptying, appetite-regulatory

  15. A rare cause of anemia due to upper gastrointestinal bleeding: Cameron lesion

    Directory of Open Access Journals (Sweden)

    Ismet Özaydın

    2014-01-01

    Full Text Available Asymptomatic large hiatal hernias may lead to iron deficiency anemia due to occult and massive bleeding from linear gastric erosions or ulcers on the mucosal folds at the level of the diaphragm called the Cameron lesions. The diagnosis is usually made during upper gastrointestinal system endoscopies. Current therapy includes the medication with proton pump inhibitors in combination with oral iron supplements and in some cases surgical reconstruction of hiatal hernia with fundoplication. We present a case of a 78-year-old woman who was admitted to the outpatient clinic with the diagnosis of iron deficiency anemia without signs of acute gastrointestinal bleeding. She was treated with medication and her follow-up gastroscopy showed a total cure. She is asymptomatic for two years after treatment with proton pump inhibitors and iron supplements. Cameron lesions should be kept in mind as an unusual cause of iron deficiency anemia due to gastrointestinal bleeding. 

  16. Microfocussing of synchrotron X-rays using X-ray refractive lens

    Indian Academy of Sciences (India)

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance ...

  17. Risk factors for upper gastrointestinal bleeding in patients referred to the Shohada Ashayer Khoramabad in 2011: Short Communication

    Directory of Open Access Journals (Sweden)

    Koorush Ghanadi

    2012-12-01

    Full Text Available Acute upper gastrointestinal bleeding is a common medical emergency that often leads to hospitalization. In the present cross-sectional study conducted during 2011, all patients with acute upper gastrointestinal bIeeding living in Khorramabad city referring to the specialized Shohada Ashayer hospital, after being matched with a control group for age and sex, were assessed. Endoscopic findings, demographic data, and clinical characteristics were collected using a questionnaire. Out of 62 patients, 67.7% were males. Mean age of the patients was 54. 5±12.1 yrs. The most frequent gastrointestinal bleeding was found in 60-79 year olds (35.5%. The ratio of gastrointestinal bleeding in regular NSAID consumption was 3.8 (CI=1.3-4.8. Hematemesis (62.9% was the most common primary presentation. The most common prevalent underlying disease predisposing bleeding in these patients was cirrhosis (61.5% and the main causes of bleeding were digestive ulcers (42.7%.

  18. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  19. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Miaja-Avila

    2015-03-01

    Full Text Available We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼106 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >107 laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  20. Excess Long-Term Mortality following Non-Variceal Upper Gastrointestinal Bleeding: A Population-Based Cohort Study

    Science.gov (United States)

    Crooks, Colin John; Card, Timothy Richard; West, Joe

    2013-01-01

    Background It is unclear whether an upper gastrointestinal bleed is an isolated gastrointestinal event or an indicator of a deterioration in a patient's overall health status. Therefore, we investigated the excess causes of death in individuals after a non-variceal bleed compared with deaths in a matched sample of the general population. Methods and Findings Linked longitudinal data from the English Hospital Episodes Statistics (HES) data, General Practice Research Database (GPRD), and Office of National Statistics death register were used to define a cohort of non-variceal bleeds between 1997 and 2010. Controls were matched at the start of the study by age, sex, practice, and year. The excess risk of each cause of death in the 5 years subsequent to a bleed was then calculated whilst adjusting for competing risks using cumulative incidence functions. 16,355 patients with a non-variceal upper gastrointestinal bleed were matched to 81,523 controls. The total 5-year risk of death due to gastrointestinal causes (malignant or non-malignant) ranged from 3.6% (≤50 years, 95% CI 3.0%–4.3%) to 15.2% (≥80 years, 14.2%–16.3%), representing an excess over controls of between 3.6% (3.0%–4.2%) and 13.4% (12.4%–14.5%), respectively. In contrast the total 5-year risk of death due to non-gastrointestinal causes ranged from 4.1% (≤50 years, 3.4%–4.8%) to 46.6% (≥80 years, 45.2%–48.1%), representing an excess over controls of between 3.8% (3.1%–4.5%) and 19.0% (17.5%–20.6%), respectively. The main limitation of this study was potential misclassification of the exposure and outcome; however, we sought to minimise this by using information derived across multiple linked datasets. Conclusions Deaths from all causes were increased following an upper gastrointestinal bleed compared to matched controls, and over half the excess risk of death was due to seemingly unrelated co-morbidity. A non-variceal bleed may therefore warrant a careful assessment of co

  1. Evaluation of scoring models for identifying the need for therapeutic intervention of upper gastrointestinal bleeding: A new prediction score model for Japanese patients.

    Science.gov (United States)

    Iino, Chikara; Mikami, Tatsuya; Igarashi, Takasato; Aihara, Tomoyuki; Ishii, Kentaro; Sakamoto, Jyuichi; Tono, Hiroshi; Fukuda, Shinsaku

    2016-11-01

    Multiple scoring systems have been developed to predict outcomes in patients with upper gastrointestinal bleeding. We determined how well these and a newly established scoring model predict the need for therapeutic intervention, excluding transfusion, in Japanese patients with upper gastrointestinal bleeding. We reviewed data from 212 consecutive patients with upper gastrointestinal bleeding. Patients requiring endoscopic intervention, operation, or interventional radiology were allocated to the therapeutic intervention group. Firstly, we compared areas under the curve for the Glasgow-Blatchford, Clinical Rockall, and AIMS65 scores. Secondly, the scores and factors likely associated with upper gastrointestinal bleeding were analyzed with a logistic regression analysis to form a new scoring model. Thirdly, the new model and the existing model were investigated to evaluate their usefulness. Therapeutic intervention was required in 109 patients (51.4%). The Glasgow-Blatchford score was superior to both the Clinical Rockall and AIMS65 scores for predicting therapeutic intervention need (area under the curve, 0.75 [95% confidence interval, 0.69-0.81] vs 0.53 [0.46-0.61] and 0.52 [0.44-0.60], respectively). Multivariate logistic regression analysis retained seven significant predictors in the model: systolic blood pressure upper gastrointestinal bleeding. © 2016 Japan Gastroenterological Endoscopy Society.

  2. X-ray instrumentation in astronomy

    International Nuclear Information System (INIS)

    Cuhlane, J.L.

    1985-01-01

    This book presents the proceedings of a conference devoted to x-ray instrumentation in astronomy. Special sections are: AXAF X-Ray Optical Systems; Specialized X-Ray Systems; X-Ray Optical Systems I; X-Ray Optical Systems II; Gas Filled X-Ray Detectors II; The NASA Advanced X-Ray Astrophysics Facility; X-Ray and EUV Spectrometers; Microchannel Plates; and Solid State Detectors

  3. Upper limits on the total cosmic-ray luminosity of individual sources

    Energy Technology Data Exchange (ETDEWEB)

    Anjos, R.C.; De Souza, V. [Instituto de Física de São Carlos, Universidade de São Paulo, São Paulo (Brazil); Supanitsky, A.D., E-mail: rita@ifsc.usp.br, E-mail: vitor@ifsc.usp.br, E-mail: supanitsky@iafe.uba.ar [Instituto de Astronomía y Física del Espacio (IAFE), CONICET-UBA, Buenos Aires (Argentina)

    2014-07-01

    In this paper, upper limits on the total luminosity of ultra-high-energy cosmic-rays (UHECR) E > 10{sup 18} eV) are determined for five individual sources. The upper limit on the integral flux of GeV--TeV gamma-rays is used to extract the upper limit on the total UHECR luminosity of individual sources. The correlation between upper limit on the integral GeV--TeV gamma-ray flux and upper limit on the UHECR luminosity is established through the cascading process that takes place during propagation of the cosmic rays in the background radiation fields, as explained in reference [1]. Twenty-eight sources measured by FERMI-LAT, VERITAS and MAGIC observatories have been studied. The measured upper limit on the GeV--TeV gamma-ray flux is restrictive enough to allow the calculation of an upper limit on the total UHECR cosmic-ray luminosity of five sources. The upper limit on the UHECR cosmic-ray luminosity of these sources is shown for several assumptions on the emission mechanism. For all studied sources an upper limit on the ultra-high-energy proton luminosity is also set.

  4. Upper limits on the total cosmic-ray luminosity of individual sources

    International Nuclear Information System (INIS)

    Anjos, R.C.; De Souza, V.; Supanitsky, A.D.

    2014-01-01

    In this paper, upper limits on the total luminosity of ultra-high-energy cosmic-rays (UHECR) E > 10 18 eV) are determined for five individual sources. The upper limit on the integral flux of GeV--TeV gamma-rays is used to extract the upper limit on the total UHECR luminosity of individual sources. The correlation between upper limit on the integral GeV--TeV gamma-ray flux and upper limit on the UHECR luminosity is established through the cascading process that takes place during propagation of the cosmic rays in the background radiation fields, as explained in reference [1]. Twenty-eight sources measured by FERMI-LAT, VERITAS and MAGIC observatories have been studied. The measured upper limit on the GeV--TeV gamma-ray flux is restrictive enough to allow the calculation of an upper limit on the total UHECR cosmic-ray luminosity of five sources. The upper limit on the UHECR cosmic-ray luminosity of these sources is shown for several assumptions on the emission mechanism. For all studied sources an upper limit on the ultra-high-energy proton luminosity is also set

  5. Non-Quiescent X-ray Emission from Neutron Stars and Black Holes

    Energy Technology Data Exchange (ETDEWEB)

    Tournear, Derek M

    2003-08-18

    X-ray astronomy began with the detection of the persistent source Scorpius X-1. Shortly afterwards, sources were detected that were variable. Centaurus X-2, was determined to be an X-ray transient, having a quiescent state, and a state that was much brighter. As X-ray astronomy progressed, classifications of transient sources developed. One class of sources, believed to be neutron stars, undergo extreme luminosity transitions lasting a few seconds. These outbursts are believed to be thermonuclear explosions occurring on the surface of neutron stars (type I X-ray bursts). Other sources undergo luminosity changes that cannot be explained by thermonuclear burning and last for days to months. These sources are soft X-ray transients (SXTs) and are believed to be the result of instabilities in the accretion of matter onto either a neutron star or black hole. Type I X-ray bursts provide a tool for probing the surfaces of neutron stars. Requiring a surface for the burning has led authors to use the presence of X-ray bursts to rule out the existence of a black hole (where an event horizon exists not a surface) for systems which exhibit type I X-ray bursts. Distinguishing between neutron stars and black holes has been a problem for decades. Narayan and Heyl have developed a theoretical framework to convert suitable upper limits on type I X-ray bursts from accreting black hole candidates (BHCs) into evidence for an event horizon. We survey 2101.2 ks of data from the USA X-ray timing experiment and 5142 ks of data from the Rossi X-ray Timing Explorer (RXTE) experiment to obtain the first formal constraint of this type. 1122 ks of neutron star data yield a population averaged mean burst rate of 1.7 {+-} 0.4 x 10{sup -5} bursts s{sup -1}, while 6081 ks of BHC data yield a 95% confidence level upper limit of 4.9 x 10{sup -7} bursts s{sup -1}. Applying the framework of Narayan and Heyl we calculate regions of luminosity where the neutron stars are expected to burst and the BHCs

  6. DETECTING RELATIVISTIC X-RAY JETS IN HIGH-REDSHIFT QUASARS

    Energy Technology Data Exchange (ETDEWEB)

    McKeough, Kathryn [Department of Statistics, Harvard University, Cambridge, MA 02138 (United States); Siemiginowska, Aneta; Kashyap, Vinay L.; Lee, N. P.; Harris, D. E.; Schwartz, D. A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Cheung, C. C. [Space Science Division, Naval Research Laboratory, Washington, DC 20375-5352 (United States); Stawarz, Łukasz [Astronomical Observatory, Jagiellonian University, ul. Orla 171, 30-244, Kraków (Poland); Stein, Nathan [Department of Statistics, The Wharton School, University of Pennsylvania, 400 Jon M. Huntsman Hall, 3730 Walnut Street, Philadelphia, PA 19104-6340 (United States); Stampoulis, Vasileios; Dyk, David A. van [Statistics Section, Imperial College London, Huxley Building, South Kensington Campus, London SW7 (United Kingdom); Wardle, J. F. C. [Department of Physics, MS 057, Brandeis University, Waltham, MA 02454 (United States); Donato, Davide [CRESST and Astroparticle Physics Laboratory NASA/GSFC, Greenbelt, MD 20771 (United States); Maraschi, Laura; Tavecchio, Fabrizio, E-mail: kathrynmckeough@g.harvard.edu [INAF Osservatorio Astronomico di Brera, via Brera 28, I-20124, Milano (Italy)

    2016-12-10

    We analyze Chandra X-ray images of a sample of 11 quasars that are known to contain kiloparsec scale radio jets. The sample consists of five high-redshift ( z  ≥ 3.6) flat-spectrum radio quasars, and six intermediate redshift (2.1 <  z  < 2.9) quasars. The data set includes four sources with integrated steep radio spectra and seven with flat radio spectra. A total of 25 radio jet features are present in this sample. We apply a Bayesian multi-scale image reconstruction method to detect and measure the X-ray emission from the jets. We compute deviations from a baseline model that does not include the jet, and compare observed X-ray images with those computed with simulated images where no jet features exist. This allows us to compute p -value upper bounds on the significance that an X-ray jet is detected in a pre-determined region of interest. We detected 12 of the features unambiguously, and an additional six marginally. We also find residual emission in the cores of three quasars and in the background of one quasar that suggest the existence of unresolved X-ray jets. The dependence of the X-ray to radio luminosity ratio on redshift is a potential diagnostic of the emission mechanism, since the inverse Compton scattering of cosmic microwave background photons (IC/CMB) is thought to be redshift dependent, whereas in synchrotron models no clear redshift dependence is expected. We find that the high-redshift jets have X-ray to radio flux ratios that are marginally inconsistent with those from lower redshifts, suggesting that either the X-ray emissions are due to the IC/CMB rather than the synchrotron process, or that high-redshift jets are qualitatively different.

  7. Guide to managing persistent upper gastrointestinal symptoms during and after treatment for cancer.

    Science.gov (United States)

    Andreyev, H Jervoise N; Muls, Ann C; Shaw, Clare; Jackson, Richard R; Gee, Caroline; Vyoral, Susan; Davies, Andrew R

    2017-10-01

    Guidance : the practical management of the gastrointestinal symptoms of pelvic radiation disease was published in 2014 for a multidisciplinary audience. Following this, a companion guide to managing upper gastrointestinal (GI) consequences was developed. The development and peer review of an algorithm which could be accessible to all types of clinicians working with patients experiencing upper GI symptoms following cancer treatment. Experts who manage patients with upper GI symptoms were asked to review the guide, rating each section for agreement with the recommended measures and suggesting amendments if necessary. Specific comments were discussed and incorporated as appropriate, and this process was repeated for a second round of review. 21 gastroenterologists, 11 upper GI surgeons, 9 specialist dietitians, 8 clinical nurse specialists, 5 clinical oncologists, 3 medical oncologists and 4 others participated in the review. Consensus (defined prospectively as 60% or more panellists selecting 'strongly agree' or 'agree') was reached for all of the original 31 sections in the guide, with a median of 90%. 85% of panellists agreed that the guide was acceptable for publication or acceptable with minor revisions. 56 of the original 61 panellists participated in round 2. 93% agreed it was acceptable for publication after the first revision. Further minor amendments were made in response to round 2. Feedback from the panel of experts developed the guide with improvement of occasional algorithmic steps, a more user-friendly layout, clearer time frames for referral to other teams and addition of procedures to the appendix.

  8. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... I’d like to talk with you about chest radiography also known as chest x-rays. Chest x-rays are the most ... far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot org. Thank you for your time! ...

  10. Miniature x-ray point source for alignment and calibration of x-ray optics

    International Nuclear Information System (INIS)

    Price, R.H.; Boyle, M.J.; Glaros, S.S.

    1977-01-01

    A miniature x-ray point source of high brightness similar to that of Rovinsky, et al. is described. One version of the x-ray source is used to align the x-ray optics on the Argus and Shiva laser systems. A second version is used to determine the spatial and spectral transmission functions of the x-ray optics. The spatial and spectral characteristics of the x-ray emission from the x-ray point source are described. The physical constraints including size, intensity and thermal limitations, and useful lifetime are discussed. The alignment and calibration techniques for various x-ray optics and detector combinations are described

  11. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  12. BLEEDING AND STARVING: fasting and delayed refeeding after upper gastrointestinal bleeding

    OpenAIRE

    FONSECA,Jorge; MEIRA,Tânia; NUNES,Ana; SANTOS,Carla Adriana

    2014-01-01

    This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. See more: http://creativecommons.org/licenses/by-nc/3.0//deed.en "Context - Early refeeding after nonvariceal upper gastrointestinal bleeding is safe and reduces hospital stay/costs. Objective - The aim of this study was obtain...

  13. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  14. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  15. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  16. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  17. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  18. Excitation mechanisms for XUV and X-ray lasers

    International Nuclear Information System (INIS)

    El-Sherbini, T.M.; Arrubban, M.M.

    1992-01-01

    Two excitation mechanisms leading to lasing action in the extreme ultraviolet and soft X-ray spectral regions are proposed. Boron- like ions of Mg VIII, Al IX and Si X plasmas are used as the active laser material. The upper laser level is the metastable 1s 2 2s 2 4p( 2 p) state while the lower level is the short lived 1s 2 2s 2 3d( 2 D) state. (author). 10 refs, 1 fig., 3 tabs

  19. X-ray scanning of overhead aurorae from rockets

    International Nuclear Information System (INIS)

    Barcus, J.R.; Goldberg, R.A.

    1981-01-01

    Two Nike Tomahawk rocket payloads were launched into energetic auroral events to investigate their structure and effects on the atmosphere. The instrument complement included X-ray scintillation detectors with energy discrimination in four ranges to measure the deposition of bremsstrahlung produced X-rays within the stratosphere and mesosphere. For this purpose, each instrument was designed for wide angle viewing; however, properties of the rocket motion have permitted coarse observation of distinct spatial X-ray structure. The detectors were mounted at a 45 0 angle with respect to the payload axis to permit scanning of the upper hemisphere, with rocket spin rates near 5 c/s during the upleg portion of each flight. Here, atmospheric shielding reduced energetic particle contamination effects to insignificant values below 65 to 75 km. Iterative computer techniques were used to reconstruct X-ray source maps at 100 km, taking atmospheric absorption effects into account. Payload 18.178 was launched on 21 September (0302 LMT) into an aurora observed to have two distinct azimuthal regions of optical brightness. Payload 18.179 (23 September, 0147 LMT) was launched into an aurora of more diffuse character. The presence of a two component spectrum is indicated for each event with the hard component originating in the more diffuse, optically faint regions. (author)

  20. Soft x-ray lasers

    International Nuclear Information System (INIS)

    Matthews, D.L.; Rosen, M.D.

    1988-01-01

    One of the elusive dreams of laser physicists has been the development of an x-ray laser. After 25 years of waiting, the x-ray laser has at last entered the scientific scene, although those now in operation are still laboratory prototypes. They produce soft x rays down to about five nanometers. X-ray lasers retain the usual characteristics of their optical counterparts: a very tight beam, spatial and temporal coherence, and extreme brightness. Present x-ray lasers are nearly 100 times brighter that the next most powerful x-ray source in the world: the electron synchrotron. Although Lawrence Livermore National Laboratory (LLNL) is widely known for its hard-x-ray laser program which has potential applications in the Strategic Defense Initiative, the soft x-ray lasers have no direct military applications. These lasers, and the scientific tools that result from their development, may one day have a place in the design and diagnosis of both laser fusion and hard x-ray lasers. The soft x-ray lasers now in operation at the LLNL have shown great promise but are still in the primitive state. Once x-ray lasers become reliable, efficient, and economical, they will have several important applications. Chief among them might be the creation of holograms of microscopic biological structures too small to be investigated with visible light. 5 figs

  1. X-ray continuum and iron K emission line from the radio galaxy 3C 390.3

    Science.gov (United States)

    Inda, M.; Makishima, K.; Kohmura, Y.; Tashiro, M.; Ohashi, T.; Barr, P.; Hayashida, K.; Palumbo, G. G. C.; Trinchieri, G.; Elvis, M.

    1994-01-01

    X-ray properties of the radio galaxy 3C 390.3 were investigated using the European X-ray Observatory Satellite (EXOSAT) and Ginga satellites. Long-term, large-amplitude X-ray intensity changes were detected over a period extending from 1984 through 1991, and high-quality X-ray spectra were obtained especially with Ginga. The X-ray continuum spectra were described with power-law model with photon slope in the range 1.5-1.8, and the slope flattened as the 2-20 keV luminosity decreased by 40%. There was a first detection of the iron emission line from this source at the 90% confidence level. An upper limit was derived on the thermal X-ray component. X-ray emission mechanisms and possible origins of the long-term variation are discussed.

  2. Early esophagogastroduodenoscopy is associated with better Outcomes in upper gastrointestinal bleeding: a nationwide study

    Science.gov (United States)

    Garg, Sushil K.; Anugwom, Chimaobi; Campbell, James; Wadhwa, Vaibhav; Gupta, Nancy; Lopez, Rocio; Shergill, Sukhman; Sanaka, Madhusudhan R.

    2017-01-01

    Background and study aims We analyzed NIS (National Inpatient Sample) database from 2007 – 2013 to determine if early esophagogastroduodenoscopy (EGD) (24 hours) for upper gastrointestinal bleeding improved the outcomes in terms of mortality, length of stay and costs. Patients and methods Patients were classified as having upper gastrointestinal hemorrhage by querying all diagnostic codes for the ICD-9-CM codes corresponding to upper gastrointestinal bleeding. For these patients, performance of EGD during admission was determined by querying all procedural codes for the ICD-9-CM codes corresponding to EGD; early EGD was defined as having EGD performed within 24 hours of admission and late EGD was defined as having EGD performed after 24 hours of admission. Results A total of 1,789,532 subjects with UGIH were identified. Subjects who had an early EGD were less likely to have hypovolemia, acute renal failure and acute respiratory failure. On multivariable analysis, we found that subjects without EGD were 3 times more likely to die during the admission than those with early EGD. In addition, those with late EGD had 50 % higher odds of dying than those with an early EGD. Also, after adjusting for all factors in the model, hospital stay was on average 3 and 3.7 days longer for subjects with no or late EGD, respectively, then for subjects with early EGD. Conclusion Early EGD (within 24 hours) is associated with lower in-hospital mortality, morbidity, shorter length of stay and lower total hospital costs. PMID:28512647

  3. Trends in Acute Nonvariceal Upper Gastrointestinal Bleeding in Dialysis Patients

    Science.gov (United States)

    Yang, Ju-Yeh; Lee, Tsung-Chun; Montez-Rath, Maria E.; Paik, Jane; Chertow, Glenn M.; Desai, Manisha

    2012-01-01

    Impaired kidney function is a risk factor for upper gastrointestinal (GI) bleeding, an event associated with poor outcomes. The burden of upper GI bleeding and its effect on patients with ESRD are not well described. Using data from the US Renal Data System, we quantified the rates of occurrence of and associated 30-day mortality from acute, nonvariceal upper GI bleeding in patients undergoing dialysis; we used medical claims and previously validated algorithms where available. Overall, 948,345 patients contributed 2,296,323 patient-years for study. The occurrence rates for upper GI bleeding were 57 and 328 episodes per 1000 person-years according to stringent and lenient definitions of acute, nonvariceal upper GI bleeding, respectively. Unadjusted occurrence rates remained flat (stringent) or increased (lenient) from 1997 to 2008; after adjustment for sociodemographic characteristics and comorbid conditions, however, we found a significant decline for both definitions (linear approximation, 2.7% and 1.5% per year, respectively; Pupper GI bleeding episodes and were more likely to receive blood transfusions during an episode. Overall 30-day mortality was 11.8%, which declined significantly over time (relative declines of 2.3% or 2.8% per year for the stringent and lenient definitions, respectively). In summary, despite declining trends worldwide, crude rates of acute, nonvariceal upper GI bleeding among patients undergoing dialysis have not decreased in the past 10 years. Although 30-day mortality related to upper GI bleeding declined, perhaps reflecting improvements in medical care, the burden on the ESRD population remains substantial. PMID:22266666

  4. INTEGRAL Upper Limits on Gamma-Ray Emission Associated with the Gravitational Wave Event GW150914

    DEFF Research Database (Denmark)

    Savchenko, V.; Ferrigno, C.; Natalucci, L.

    Using observations of the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL), we place upper limits on the gamma-ray and hard X-ray prompt emission associated with the gravitational wave event GW150914, discovered by the LIGO/Virgo Collaboration. The omnidirectional view of the INTEGRAL...... MeV energy range for typical spectral models. Our results constrain the ratio of the energy promptly released in gamma-rays in the direction of the observer to the gravitational wave energy Eγ/EGW gravitational wave...

  5. Frequency filter of seed x-ray by use of x-ray laser medium. Toward the generation of the temporally coherent x-ray laser

    International Nuclear Information System (INIS)

    Hasegawa, Noboru; Kawachi, Tetsuya; Kishimoto, Maki; Sukegawa, Kouta; Tanaka, Momoko; Ochi, Yoshihiro; Nishikino, Masaharu; Nagashima, Keisuke; Kato, Yoshiaki; Renzhong, Tai

    2009-01-01

    We evaluate the characteristics of a higher-order harmonics light as a seed X-ray amplified through a laser-produced X-ray amplifier. The narrow spectral bandwidth of the X-ray amplifier works as the frequency filter of the seed X-ray, resulting in that only the temporally coherent X-ray is amplified. Experimental investigation using the 29th-order harmonic light of the Ti:sapphire laser at a wavelength of 26.9 nm together with a neon-like manganese X-ray laser medium shows evident spectral narrowing of the seed X-ray and amplification without serious diffraction effects on the propagation of the amplified X-ray beam. This implies that the present combination is potential to realize temporally coherent X-ray lasers, with an expected duration of approximately 400 fs. (author)

  6. Interventional treatment of upper gastrointestinal bleeding in patients of hepatic carcinoma accompanied with hepatic artery-portal vein shunting

    International Nuclear Information System (INIS)

    Li Jijun; Shang Jianqiang; Liu Zuoqin; Tang Jun; Sun Zengtao; Chen Jie; Zhang Lei; Liu Hongjun; Zhou Zhaohai

    2011-01-01

    Objective: To explore the diagnostic and therapeutic efficacy of interventional procedure for upper gastrointestinal bleeding in patients of hepatic carcinoma accompanied with hepatic artery-portal vein shunting (HAPVS). Methods: Clinical data of 27 patients of hepatic carcinoma accompanied with HAPVS were retrospectively analyzed. All patients underwent hepatic arterial angiography and transcatheter arterial embolization. Shunts were embolized with coils, Gelfoam particles or PVA particles. Results: Of 27 patients with upper gastrointestinal bleeding, central type HAPVS was seen in 16 and peripheral type HAPVS in 11. Reversed portal venous flow was detected in 20 cases and ascites was found in 23 cases. The abnormal shunts were successfully occluded in all patients and the bleeding ceased within 2 days after embolization. No recurrent bleeding occurred in one month after the treatment. Ascites disappeared in 16 cases and subsided in 7 cases. Conclusion: HAPVS is an important cause for upper gastrointestinal bleeding in patients of hepatic carcinoma, and the arteriovenous fistula can be confirmed with hepatic artery DSA. Embolization of fistulous orifice is the most effective therapy for such patients. (authors)

  7. Joint European x-ray monitor (JEM-X): x-ray monitor for ESA's

    DEFF Research Database (Denmark)

    Schnopper, H.W.; Budtz-Joergensen, C.; Westergaard, Niels Jørgen Stenfeldt

    1996-01-01

    JEM-X will extend the energy range of the gamma ray instruments on ESA's INTEGRAL mission (SPI, IBIS) to include the x-ray band. JEM-X will provide images with arcminute angular resolution in the 2 - 60 keV band. The baseline photon detection system consists of two identical, high pressure, imagi...

  8. Wide field x-ray telescopes: Detecting x-ray transients/afterglows related to GRBs

    International Nuclear Information System (INIS)

    Hudec, Rene; Pina, Ladislav; Inneman, Adolf; Gorenstein, Paul

    1998-01-01

    The recent discovery of X-ray afterglows of GRBs opens the possibility of analyses of GRBs by their X-ray detections. However, imaging X-ray telescopes in current use mostly have limited fields of view. Alternative X-ray optics geometries achieving very large fields of view have been theoretically suggested in the 70's but not constructed and used so far. We review the geometries and basic properties of the wide-field X-ray optical systems based on one- and two-dimensional lobster-eye geometry and suggest technologies for their development and construction. First results of the development of double replicated X-ray reflecting flats for use in one-dimensional X-ray optics of lobster-eye type are presented and discussed. The optimum strategy for locating GRBs upon their X-ray counterparts is also presented and discussed

  9. A Canadian Clinical Practice Algorithm for the Management of Patients with Non-Variceal Upper Gastrointestinal Bleeding

    Directory of Open Access Journals (Sweden)

    Alan Barkun

    2004-01-01

    Full Text Available AIM: To use current evidence-based recommendations to provide a user-friendly clinical algorithm for the management of upper gastrointestinal bleeding, adapted to the Canadian environment.

  10. Upper Gastrointestinal Involvement in Crohn Disease: Histopathologic and Endoscopic Findings.

    Science.gov (United States)

    Diaz, Liege; Hernandez-Oquet, Rafael Enrique; Deshpande, Amar R; Moshiree, Baharak

    2015-11-01

    Studies describing the prevalence of upper gastrointestinal (GI) Crohn disease (CD) and its histopathologic changes have been inconsistent as a result of different definitions used for upper GI involvement, diverse populations, and varying indications for endoscopy. We reviewed the literature describing endoscopic findings and histologic lesions in gastric and duodenal mucosa of patients with established CD. PubMed, EMBASE, and the Cochrane Library were searched for gastroduodenal biopsy findings in patients with CD from 1970 to 2014. We included all retrospective and prospective studies in adults. We calculated the prevalence of the most common endoscopic and histopathological findings among patients with overall CD and upper GI CD. Of the 385 articles identified, 20 eligible studies were included. A total of 2511 patients had CD and 815 had upper GI CD. In the CD group, the most common histopathological finding was nonspecific gastric inflammation in 32% of patients, followed by gastric granuloma in 7.9%. Focal gastritis was prevalent in 30.9% of patients. In the upper GI CD group, gastric inflammation was present in 84% of patients, followed by duodenal inflammation in 28.2% and gastric granuloma in 23.2%. The most common gastric endoscopic finding in patients with CD was erythema in 5.9%, followed by erosions in 3.7%. Duodenal endoscopic findings included ulcers and erythema in 5.3% and 3.0% of patients, respectively. We found a prevalence of 34% for CD involving the upper GI tract across these 20 studies. Routine upper endoscopy with biopsies of the upper GI tract in the diagnostic workup of patients with CD can correctly classify the distribution and extent of the disease.

  11. Validity of peptic ulcer disease and upper gastrointestinal bleeding diagnoses in administrative databases: a systematic review protocol.

    Science.gov (United States)

    Montedori, Alessandro; Abraha, Iosief; Chiatti, Carlos; Cozzolino, Francesco; Orso, Massimiliano; Luchetta, Maria Laura; Rimland, Joseph M; Ambrosio, Giuseppe

    2016-09-15

    Administrative healthcare databases are useful to investigate the epidemiology, health outcomes, quality indicators and healthcare utilisation concerning peptic ulcers and gastrointestinal bleeding, but the databases need to be validated in order to be a reliable source for research. The aim of this protocol is to perform the first systematic review of studies reporting the validation of International Classification of Diseases, 9th Revision and 10th version (ICD-9 and ICD-10) codes for peptic ulcer and upper gastrointestinal bleeding diagnoses. MEDLINE, EMBASE, Web of Science and the Cochrane Library databases will be searched, using appropriate search strategies. We will include validation studies that used administrative data to identify peptic ulcer disease and upper gastrointestinal bleeding diagnoses or studies that evaluated the validity of peptic ulcer and upper gastrointestinal bleeding codes in administrative data. The following inclusion criteria will be used: (a) the presence of a reference standard case definition for the diseases of interest; (b) the presence of at least one test measure (eg, sensitivity, etc) and (c) the use of an administrative database as a source of data. Pairs of reviewers will independently abstract data using standardised forms and will evaluate quality using the checklist of the Standards for Reporting of Diagnostic Accuracy (STARD) criteria. This systematic review protocol has been produced in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis Protocol (PRISMA-P) 2015 statement. Ethics approval is not required given that this is a protocol for a systematic review. We will submit results of this study to a peer-reviewed journal for publication. The results will serve as a guide for researchers validating administrative healthcare databases to determine appropriate case definitions for peptic ulcer disease and upper gastrointestinal bleeding, as well as to perform outcome research using

  12. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  13. Extending the methodology of X-ray crystallography to allow X-ray microscopy without X-ray optics

    International Nuclear Information System (INIS)

    Miao Jianwei; Kirz, Janos; Sayre, David; Charalambous, Pambos

    2000-01-01

    We demonstrate that the soft X-ray diffraction pattern from a micron-size noncrystalline specimen can be recorded and inverted to form a high-resolution image. The phase problem is overcome by oversampling the diffraction pattern. The image is obtained using an iterative algorithm. The technique provides a method for X-ray microscopy requiring no high-resolution X-ray optical elements or detectors. In the present work, a resolution of approximately 60 nm was obtained, but we believe that considerably higher resolution can be achieved

  14. Dental X-ray apparatus

    International Nuclear Information System (INIS)

    Weiss, M.E.

    1980-01-01

    Intra-oral dental X-ray apparatus for panoramic radiography is described in detail. It comprises a tubular target carrier supporting at its distal end a target with an inclined forward face. Image definition is improved by positioning in the path of the X-rays a window of X-ray transmitting ceramic material, e.g. 90% oxide of Be, or Al, 7% Si0 2 . The target carrier forms a probe which can be positioned in the patient's mouth. X-rays are directed forwardly and laterally of the target to an X-ray film positioned externally. The probe is provided with a detachable sleeve having V-form arms of X-ray opaque material which serve to depress the tongue out of the radiation path and also shield the roof of the mouth and other regions of the head from the X-ray pattern. A cylindrical lead shield defines the X-ray beam angle. (author)

  15. Confocal endomicroscopy for in vivo microscopic analysis of upper gastrointestinal tract premalignant and malignant lesions.

    Science.gov (United States)

    Gheorghe, Cristian; Iacob, Razvan; Becheanu, Gabriel; Dumbrav Abreve, Mona

    2008-03-01

    Confocal LASER endomicroscopy (CLE) is a new endoscopic technique which allows subsurface in vivo microscopic analysis during ongoing endoscopy, using systemically or topically administered fluorescent agents. It allows targeted biopsies to be taken, potentially improving the diagnostic rate in certain gastrointestinal diseases. Worldwide experience with CLE for upper gastrointestinal malignant and premalignant lesions is still reduced. Potential clinical applications are presented, including diagnosis of NERD, Barrett's esophagus, atrophic gatritis, gastric intestinal metaplasia and dysplasia, gastric adenomatous or hyperplastic polyps, gastric cancer.

  16. Telemetric real-time sensor for the detection of acute upper gastrointestinal bleeding.

    Science.gov (United States)

    Schostek, Sebastian; Zimmermann, Melanie; Keller, Jan; Fode, Mario; Melbert, Michael; Schurr, Marc O; Gottwald, Thomas; Prosst, Ruediger L

    2016-04-15

    Acute upper gastrointestinal bleedings from ulcers or esophago-gastric varices are life threatening medical conditions which require immediate endoscopic therapy. Despite successful endoscopic hemostasis, there is a significant risk of rebleeding often requiring close surveillance of these patients in the intensive care unit (ICU). Any time delay to recognize bleeding may lead to a high blood loss and increases the risk of death. A novel telemetric real-time bleeding sensor can help indicate blood in the stomach: the sensor is swallowed to detect active bleeding or is anchored endoscopically on the gastrointestinal wall close to the potential bleeding source. By telemetric communication with an extra-corporeal receiver, information about the bleeding status is displayed. In this study the novel sensor, which measures characteristic optical properties of blood, has been evaluated in an ex-vivo setting to assess its clinical applicability and usability. Human venous blood of different concentrations, various fluids, and liquid food were tested. The LED-based sensor was able to reliably distinguish between concentrated blood and other liquids, especially red-colored fluids. In addition, the spectrometric quality of the small sensor (size: 6.5mm in diameter, 25.5mm in length) was comparable to a much larger and technically more complex laboratory spectrophotometer. The experimental data confirm the capability of a miniaturized sensor to identify concentrated blood, which could help in the very near future the detection of upper gastrointestinal bleeding and to survey high-risk patients for rebleeding. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. X-ray diagnostics for TFTR

    International Nuclear Information System (INIS)

    von Goeler, S.; Hill, K.W.; Bitter, M.

    1982-12-01

    A short description of the x-ray diagnostic preparation for the TFTR tokamak is given. The x-ray equipment consists of the limiter x-ray monitoring system, the soft x-ray pulse-height-analysis-system, the soft x-ray imaging system and the x-ray crystal spectrometer. Particular attention is given to the radiation protection of the x-ray systems from the neutron environment

  18. [High risk factors of upper gastrointestinal bleeding after neurosurgical procedures].

    Science.gov (United States)

    Zheng, Kang; Wu, Gang; Cheng, Neng-neng; Yao, Cheng-jun; Zhou, Liang-fu

    2005-12-21

    To analyze high risk factors of postoperative upper gastrointestinal (GI) bleeding after neurosurgery so as to give guidance for prevention of GI bleeding. A questionnaire was developed to investigate the medical records of 1500 patients who were hospitalized and underwent neurosurgical operations in 1997. Logistic regression analysis was made. 1430 valid questionnaires were obtained. Postoperative upper GI bleeding occurred in 75 patients (5.24%). The incidence of upper GI bleeding were 6.64% (54/813) in the male patients and 3.40% (21/617) in the female persons (P = 0.007); 9.88% (41/415) in those aged > 50 and 3.35% in those aged hematoma, intraventricular hemorrhage, subdural hematoma, and extradural hematoma were 15.7%, 10.0%, 6.00%, and 2.94% respectively (P = 0.02). The incidence of upper GI bleeding of the patients with tumors of fourth ventricle of cerebrum, brainstem, cerebral hemisphere, and sellar hypothalamus were 15.79% (3/19), 7.89%, 5.71%, and 3.74% respectively. In the emergent cases, the incidence of upper GI bleeding was higher in those with hypertension. The incidence of upper GI bleeding was 5.46% in the patients undergoing adrenocortical hormone treatment, significantly higher than that in those who did not receive such treatment (2.13%). Patients who are at high risk of developing postoperative upper GI bleeding including that: age greater than 50 years; male; Glasgow Coma Score less than 10 pre and post operation; The lesion was located in brain stem and forth ventricle; Hypertensive cerebral hemorrhage; Intracerebral and intraventricular hemorrhagic brain trauma; Postoperative pneumonia, brain edema, encephalic high pressure, pyogenic infection of the central nervous system and other postoperative complications. The mortality of patients with postoperative upper GI bleeding was evidently higher than that of the patients without postoperative upper GI bleeding.

  19. The peculiarities of combined pathology of the upper gastrointestinal tract with allergic dermatoses in children

    Directory of Open Access Journals (Sweden)

    T.V. Sorokman

    2017-04-01

    Full Text Available Background. The recent studies indicate that one of the causes of allergic dermatoses (AD in children and adults is pathology of the gastrointestinal tract. However, many problems of the emergence of these combinations have not yet been resolved. The purpose of the study was to establish the incidence and the nature of lesions of the upper gastrointestinal tract (UGIT in children with allergic dermatoses. Materials and methods. On the base of the Chernivtsi Regional Children’s Hospital, 40 children with allergic dermatoses combined with the pathology of the upper gastrointestinal tract and 20 patients with AD, but without the UGIT pathology, aged 3 to 18 years were examined. A clinical and laboratory studies were conducted twice (routine clinical tests, chamber scratch test with non-infectious allergens during AD remission, as well as fibrogastroduodenoscopy, ultrasound, pH-measuring biochemical blood tests (alanine aminotransferase (ALT, aspartate aminotransferase (AST, gamma glutaminetransferase (GGTP, alkaline phosphatase, cholesterol, identification of H.pylori. Results. It was indicated that out of 40 examined children with AD, 30 (75 % persons had various lesions of the esophagus, stomach and duodenum. In 10 (25 % children, the functional changes, such as duodenogastral reflex (70 % and failure of the cardia (30 %, were detected. A multiple nature of reflux was observed in 85.7 % of children with chronic gastroduodenitis and in 100 % of children with esophagitis and duodenal ulcer disease. The contamination with H.pylori was detected in 72.5 % of cases. The increased activity of ALT and AST, GGTP, alkaline phosphatase and serum cholesterol was established. Conclusion. In 75 % of children with allergic dermatoses, an organic pathology of the upper gastrointestinal tract was diagnosed, thus, a gastroenterological examination should be recommended to all patients.

  20. Radiation Dose Measurements in Routine X Ray Examinations

    International Nuclear Information System (INIS)

    Osman, H.; Sulieman, A.; Suliman, I.I.; Sam, A.K.

    2011-01-01

    The aim of current study was to evaluate patients radiation dose in routine X-ray examinations in Omdurman teaching hospital Sudan.110 patients was examined (134) radiographs in two X-ray rooms. Entrance surface doses (ESDs) were calculated from patient exposure parameters using DosCal software. The mean ESD for the chest, AP abdomen, AP pelvis, thoracic spine AP, lateral lumber spine, anteroposterior lumber spine, lower limb and for the upper limb were; 231±44 Gy,453± 29 Gy, 567±22 Gy, 311±33 Gy,716±39 Gy, 611±55 Gy,311±23 Gy, and 158±57 Gy, respectively. Data shows asymmetry in distribution. The results of were comparable with previous study in Sudan.

  1. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  2. Flexible endoscopic procedure in children with foreign bodies in their upper gastrointestinal system

    Directory of Open Access Journals (Sweden)

    Kaan Demirören

    2014-03-01

    Full Text Available Objective: Foreign body ingestion is an important public health problem. We pointed to this subject and aimed to determine the effectiveness of flexible endoscopic procedure in this study. Methods: We evaluated retrospectively fifty children having foreign body in their upper gastrointestinal system, who underwent flexible endoscopic procedure. Results: Of the patients, mean age was 5.5 ± 4 years old (range: 0.5-16 years, 64% was female. Ingested foreign bodies were coin (58%, pin (10%, battery (6%, nail (6%, necklace (6%, safety pin (4% and sewing pin, wire hairclip, ring, button and chicken skin. In endoscopic procedure, foreign bodies were seen in upper esophagus (32%, middle esophagus (26%, lower esophagus (8%, stomach (18%, bulbus (4% and second part of duodenum (8%, but were not seen in 4% of the cases. While 94% of foreign bodies were endoscopically removed, 6% of them were pushed to stomach with gastroscope from esophagus and left for spontaneous passage. Any important complication was developed. Conclusion: Flexible endoscopic procedure is an effective and safe method for removal of gastrointestinal system foreign bodies in children.

  3. Retrospective analysis of surgery and trans-arterial embolization for major non-variceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Griffiths, Ewen A; McDonald, Chris R; Bryant, Robert V; Devitt, Peter G; Bright, Tim; Holloway, Richard H; Thompson, Sarah K

    2016-05-01

    With proton pump inhibitors and current sophisticated endoscopic techniques, the number of patients requiring surgical intervention for upper gastrointestinal bleeding has decreased considerably while trans-arterial embolization is being used more often. There are few direct comparisons between the effectiveness of surgery and embolization. A retrospective study of patients from two Australian teaching hospitals who had surgery or trans-arterial embolization (n = 103) for severe upper gastrointestinal haemorrhage between 2004 and 2012 was carried out. Patient demographics, co-morbidities, disease pathology, length of stay, complications, and overall clinical outcome and mortality were compared. There were 65 men and 38 women. The median age was 70 (range 36-95) years. Patients requiring emergency surgical intervention (n = 79) or trans-arterial embolization (n = 24) were compared. The rate of re-bleeding after embolization (42%) was significantly higher compared with the surgery group (19%) (P = 0.02). The requirement for further intervention (either surgery or embolization) was also higher in the embolization group (33%) compared with the surgery group (13%) (P = 0.03). There was no statistical difference in mortality between the embolization group (5/24, 20.8%) and the surgical group (13/79, 16.5%) (P = 0.75). Emergency surgery and embolization are required in 2.6% of patients with upper gastrointestinal bleeding. Both techniques have high mortalities reflecting the age, co-morbidities and severity of bleeding in this patient group. © 2014 Royal Australasian College of Surgeons.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to ...

  5. Hemospray application in nonvariceal upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Smith, Lyn A; Stanley, Adrian J; Bergman, Jacques J

    2013-01-01

    BACKGROUND: Hemospray TM (TC-325) is a novel hemostatic agent licensed for use in nonvariceal upper gastrointestinal bleeding (NVUGIB) in Europe. GOALS: We present the operating characteristics and performance of TC-325 in the largest registry to date of patients presenting with NVUGIB in everyday...... in combination with other hemostatic modalities at the endoscopists' discretion. RESULTS: Sixty-three patients (44 men, 19 women), median age 69 (range, 21 to 98) years with NVUGIB requiring endoscopic hemostasis were treated with TC-325. There were 30 patients with bleeding ulcers and 33 with other NVUGIB...... pathology. Fifty-five (87%) were treated with TC-325 as monotherapy; 47 [85%; 95% confidence interval (CI), 76%-94%] of them achieved primary hemostasis, and rebleeding rate at 7 days was 15% (95% CI, 5%-25%). Primary hemostasis rate for TC-325 in patients with ulcer bleeds was 76% (95% CI, 59%-93%). Eight...

  6. Risk Factors Associated with Mortality and Increased Drug Costs in Nonvariceal Upper Gastrointestinal Bleeding.

    Science.gov (United States)

    Lu, Mingliang; Sun, Gang; Zhang, Xiu-li; Zhang, Xiao-mei; Liu, Qing-sen; Huang, Qi-yang; Lau, James W Y; Yang, Yun-sheng

    2015-06-01

    To determine risk factors associated with mortality and increased drug costs in patients with nonvariceal upper gastrointestinal bleeding. We retrospectively analyzed data from patients hospitalized with nonvariceal upper gastrointestinal bleeding between January 2001-December 2011. Demographic and clinical characteristics and drug costs were documented. Univariate analysis determined possible risk factors for mortality. Statistically significant variables were analyzed using a logistic regression model. Multiple linear regression analyzed factors influencing drug costs. p study included data from 627 patients. Risk factors associated with increased mortality were age > 60, systolic blood pressurebleeding rate is 11.20% and mortality is 5.74%. The mortality risk in patients with comorbidities was higher than in patients without comorbidities, and was higher in patients requiring blood transfusion than in patients not requiring transfusion. Rebleeding was associ-ated with mortality. Rebleeding, blood transfusion, and prolonged hospital stay were associated with increased drug costs, whereas bleeding from lesions in the esophagus and duodenum was associated with lower drug costs.

  7. High-energy Neutrino Flares from X-Ray Bright and Dark Tidal Disruption Events

    Energy Technology Data Exchange (ETDEWEB)

    Senno, Nicholas; Murase, Kohta; Mészáros, Peter [Department of Physics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2017-03-20

    X-ray and γ-ray observations by the Swift satellite revealed that a fraction of tidal disruption events (TDEs) have relativistic jets. Jetted TDEs have been considered to be potential sources of very-high-energy cosmic-rays and neutrinos. In this work, using semi-analytical methods, we calculate neutrino spectra of X-ray bright TDEs with powerful jets and dark TDEs with possible choked jets, respectively. We estimate their neutrino fluxes and find that non-detection would give us an upper limit on the baryon loading of the jet luminosity contained in cosmic-rays ξ {sub cr} ≲ 20–50 for Sw J1644+57. We show that X-ray bright TDEs make a sub-dominant (≲5%–10%) contribution to IceCube’s diffuse neutrino flux, and study possible contributions of X-ray dark TDEs given that particles are accelerated in choked jets or disk winds. We discuss future prospects for multi-messenger searches of the brightest TDEs.

  8. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  9. Evaluation of patients with upper gastrointestinal bleeding in chronic renal failure

    Directory of Open Access Journals (Sweden)

    Mehmet Sinan Dal

    2011-06-01

    Full Text Available Incidence of gastrointestinal complications especially gastric bleeding increased in patients with chronic renal failure (CRF. The aim of this study was to comparatively investigate upper gastrointestinal bleeding (UGB in patients with non-hemodialysis CRF and the patients without CRF.Materials and Methods: Seventy-six patients (55 men and 21 women with and without CRF and UGB was included. The first group who had CRF consisted of 23 patients and the control group 53. All patients were evaluated in the view point of age, gender, smoking status, other illnesses, medicine usage, laboratory parameters, endoscopic evidence and endoscopic intervention (scleroteraphy.Results: Calcium levels of patients with a history of previous UGB was significantly lower compared with those bleeding for the first time (p<0.05. The mean parathormon level was higher in patients with CRF (171.24 ± 141.96 pg/ml (p<0.05. Serum albumin level was negatively correlated with urea and creatinine (p<0.001, and positively correlated with hemoglobin and hematocrit levels (p=0.003 and p=0.005. The patients undergoing sclerotherapy more frequently needed transfusions (p<0.05. The hospitalization time found to be shortening with increasing hemoglobin, hematocrit, calcium and albumin levels; and lengthens with increased urea and creatinine.Conclusion: The history of previous gastrointestinal bleeding and detection of pathological findings in endoscopy were more frequent in patients with CRF. Gastrointestinal bleeding risk did not reduce using by gastric protection against acetylsalicylic acid and other non-steroidal antiinflammatory drugs. Also, low albumin levels and secondary hiperparathyroidism in these patients may be risky for gastrointestinal bleeding. J Clin Exp Invest 2011;2(2:207-13

  10. X-ray apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1985-01-01

    X-ray apparatus is described which has a shutter between the X-ray source and the patient. The shutter controls the level of radiation to which the patient is exposed instead of merely discontinuing the electric power supplied to the source. When the shutter is opened a radiation sensor senses the level of X-radiation. When a preset quantity of X-radiation has been measured an exposure control closes the shutter. Instead of using the radiation sensor, the integrated power supplied to the anode of the X-ray source may be measured. (author)

  11. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2015-03-10

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  12. Outcome of index upper gastrointestinal endoscopy in patients presenting with dysphagia in a tertiary care hospital-A 10 years review

    Science.gov (United States)

    Qureshi, Nafees A; Hallissey, Michael T; Fielding, John W

    2007-01-01

    Background Patients with malignant tumours of the upper gastrointestinal tract tumours exhibit important alarm symptoms such as dysphagia that warrant clinical investigations. An endoscopic examination of the upper gastrointestinal tract will be required in most cases. This study evaluates the diagnostic potential of index endoscopy in a random population of patients with dysphagia. Methods This is a retrospective analysis of prospectively collected data over 10 years. Patients with previous endoscopic evaluation or upper gastrointestinal pathology were excluded from the study. Data was analysed to see the number and frequency of abnormal findings in upper gastrointestinal tract, and their significance in relation to the presenting symptoms. Results Total number of index endoscopies was 13, 881. 913 patients were included in the study including 465 males (age range: 17–92 years, median: 55 years) and 448 females (age range: 18–100, median: 59 years), with male to female ratio of 1.04: 1. Oesophagus was abnormal in 678 cases (74%) and biopsies were taken in 428 patients (47%). Superficial oesophagitis, Barrett's oesophagus, oesophageal cancer, and oesophageal ulcer were main histological findings. Age more than 50 years and weight loss were significant predictors of oesophageal cancer (p dysphagia, especially males above the age of 50 years. Patients may be started on treatment or referred for further investigations, for example, a barium meal in the absence of any anatomical abnormality. PMID:18034883

  13. Optical and X-ray studies of Compact X-ray Binaries in NGC 5904

    Science.gov (United States)

    Bhalotia, Vanshree; Beck-Winchatz, Bernhard

    2018-06-01

    Due to their high stellar densities, globular cluster systems trigger various dynamical interactions, such as the formation of compact X-ray binaries. Stellar collisional frequencies have been correlated to the number of X-ray sources detected in various clusters and we hope to measure this correlation for NGC 5904. Optical fluxes of sources from archival HST images of NGC 5904 have been measured using a DOLPHOT PSF photometry in the UV, optical and near-infrared. We developed a data analysis pipeline to process the fluxes of tens of thousands of objects using awk, python and DOLPHOT. We plot color magnitude diagrams in different photometric bands in order to identify outliers that could be X-ray binaries, since they do not evolve the same way as singular stars. Aligning previously measured astrometric data for X-ray sources in NGC 5904 from Chandra with archival astrometric data from HST will filter out the outlier objects that are not X-ray producing, and provide a sample of compact binary systems that are responsible for X-ray emission in NGC 5904. Furthermore, previously measured X-ray fluxes of NGC 5904 from Chandra have also been used to measure the X-ray to optical flux ratio and identify the types of compact X-ray binaries responsible for the X-ray emissions in NGC 5904. We gratefully acknowledge the support from the Illinois Space Grant Consortium.

  14. CCD-based X-ray detectors for X-ray diffraction studies

    International Nuclear Information System (INIS)

    Ito, K.; Amemiya, Y.

    1999-01-01

    CCD-based X-ray detectors are getting to be used for X-ray diffraction studies especially in the studies where real time (automated) measurements and time-resolved measurements are required. Principles and designs of two typical types of CCD-based detectors are described; one is ths system in which x-ray image intensifiers are coupled to maximize the detective quantum efficiency for time-resolved measurements, and the other is the system in which tapered optical fibers are coupled for the reduction of the image into the CCD, which is optimized for automated measurements for protein crystallography. These CCD-based X-ray detectors have an image distortion and non-uniformity of response to be corrected by software. Correction schemes which we have developed are also described. (author)

  15. Arterial lactate does not predict outcome better than existing risk scores in upper gastrointestinal bleeding

    DEFF Research Database (Denmark)

    Stokbro, Line Aabel; Schaffalitzky de Muckadell, Ove B; Laursen, Stig Borbjerg

    2018-01-01

    OBJECTIVE: Upper gastrointestinal bleeding (UGIB) is a frequent medical emergency and several scoring systems are developed to help risk-stratify patients. We aimed to investigate if elevated arterial lactate (AL) was associated with 30-day mortality, need for hospital-based intervention...

  16. Simulation of transmitted X-rays in a polycapillary X-ray lens

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Shiqi [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Liu, Zhiguo, E-mail: liuzhiguo512@126.com [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi; Wang, Kai; Yi, Longtao; Yang, Kui; Chen, Man; Wang, Jinbang [The Key Laboratory of Beam Technology and Material Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2015-09-21

    The geometrical description of capillary systems adjusted for the controlled guiding of X-rays and the basic theory of the transmission of X-rays are presented. A method of numerical calculation, based on Ray-Tracing theory, is developed to simulate the transmission efficiency of an X-ray parallel lens and the shape and size of the light spot gain from it. The simulation results for two half-lenses are in good agreement with the experimental results.

  17. Microfocussing of synchrotron X-rays using X-ray refractive lens developed at Indus-2 deep X-ray lithography beamline

    International Nuclear Information System (INIS)

    Dhamgaye, V.P.; Tiwari, M.K.; Lodha, G.S.; Sawhney, K.J.S.

    2014-01-01

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance sources are compared. (author)

  18. X pinch a point x-ray source

    International Nuclear Information System (INIS)

    Garg, A.B.; Rout, R.K.; Shyam, A.; Srinivasan, M.

    1993-01-01

    X ray emission from an X pinch, a point x-ray source has been studied using a pin-hole camera by a 30 kV, 7.2 μ F capacitor bank. The wires of different material like W, Mo, Cu, S.S.(stainless steel) and Ti were used. Molybdenum pinch gives the most intense x-rays and stainless steel gives the minimum intensity x-rays for same bank energy (∼ 3.2 kJ). Point x-ray source of size (≤ 0.5 mm) was observed using pin hole camera. The size of the source is limited by the size of the pin hole camera. The peak current in the load is approximately 150 kA. The point x-ray source could be useful in many fields like micro lithography, medicine and to study the basic physics of high Z plasmas. (author). 4 refs., 3 figs

  19. The mechanism of combination with hemocoagulase and pantoprazole in upper gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    Ming-Ke Yan

    2017-03-01

    Full Text Available Objective: Through the combination with hemocoagulase and pantoprazole on gastrointestinal bleeding, to observe the changes of serum BUN (blood urea nitrogen, LPO (LPO, NO (nitric oxide, TNF-α(TNF alpha, hs-CRP (high sensitivity C reactive protein and cortisol levels, and to explore the mechanism of combination. Methods: 110 cases of upper gastrointestinal bleeding in our hospital from January 2015 to September 2016 were selected and divided into the control group and the observation group, 55 cases for each group. Patients were treated with bed rest, fasting, intravenous nutrition, oxygen, and according to the individual situation actively supplement blood capacity, and the control group were treated with 40 mg intravenous pantoprazole treatment, 2 times/d; the patients in the observation group were treated with 2 kU hemocoagulase injection based on the treatment of control group, 2 times of intravenous injection per day, and all patients were treated for 3 d, and then the BUN, LPO, NO, TNF-α, hs-CRP and cortisol were detected. Results: (1 There were no significantly differences of the serum levels of BUN, LPO, and NO of the two groups before treatment (P>0.05. After treatment, the serum levels the two groups were significantly lower than before treatment, and LPO, BUN, and NO levels in the observation group were significantly better than the control group (P0.05. After treatment, the serum levels in the two groups were significantly lower than before treatment, and TNF-α, hs-CRP, and cortisol levels in the observation group were significantly better than the control group (P<0.05. Conclusions: The treatment of patients with combined use of hemocoagulase and pantoprazole on gastrointestinal bleeding, can significantly improve the serum levels of BUN, LPO, NO, TNF-α, hs-CRP and cortisol levels, and further illustrates the synergistic effect of the combination, also shows that the combination of two drugs for patients with upper

  20. Fermi Non-detections of Four X-Ray Jet Sources and Implications for the IC/CMB Mechanism

    Science.gov (United States)

    Breiding, Peter; Meyer, Eileen T.; Georganopoulos, Markos; Keenan, M. E.; DeNigris, N. S.; Hewitt, Jennifer

    2017-11-01

    Since its launch in 1999, the Chandra X-ray observatory has discovered several dozen X-ray jets associated with powerful quasars. In many cases, the X-ray spectrum is hard and appears to come from a second spectral component. The most popular explanation for the kpc-scale X-ray emission in these cases has been inverse-Compton (IC) scattering of Cosmic Microwave Background (CMB) photons by relativistic electrons in the jet (the IC/CMB model). Requiring the IC/CMB emission to reproduce the observed X-ray flux density inevitably predicts a high level of gamma-ray emission, which should be detectable with the Fermi Large Area Telescope (LAT). In previous work, we found that gamma-ray upper limits from the large-scale jets of 3C 273 and PKS 0637-752 violate the predictions of the IC/CMB model. Here, we present Fermi/LAT flux density upper limits for the X-ray jets of four additional sources: PKS 1136-135, PKS 1229-021, PKS 1354+195, and PKS 2209+080. We show that these limits violate the IC/CMB predictions at a very high significance level. We also present new Hubble Space Telescope observations of the quasar PKS 2209+080 showing a newly detected optical jet, and Atacama Large Millimeter/submillimeter Array band 3 and 6 observations of all four sources, which provide key constraints on the spectral shape that enable us to rule out the IC/CMB model.

  1. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  2. Compact X-ray sources: X-rays from self-reflection

    Science.gov (United States)

    Mangles, Stuart P. D.

    2012-05-01

    Laser-based particle acceleration offers a way to reduce the size of hard-X-ray sources. Scientists have now developed a simple scheme that produces a bright flash of hard X-rays by using a single laser pulse both to generate and to scatter an electron beam.

  3. UPPER LIMITS ON PULSED RADIO EMISSION FROM THE 6.85 s X-RAY PULSAR XTE J0103-728 IN THE SMALL MAGELLANIC CLOUD

    International Nuclear Information System (INIS)

    Crawford, Fronefield; Devour, Brian M.; Takacs, Brian P.; Lorimer, Duncan R.; Kondratiev, Vladislav I.

    2009-01-01

    X-ray pulsations with a 6.85 s period were recently detected in the Small Magellanic Cloud (SMC) and were subsequently identified as originating from the Be/X-ray binary system XTE J0103-728. The recent localization of the source of the X-ray emission has made a targeted search for radio pulsations from this source possible. The detection of pulsed radio emission from XTE J0103-728 would make it only the second system after PSR B1259-63 that is both a Be/X-ray binary and a radio pulsar. We observed XTE J0103-728 in 2008 February with the Parkes 64 m radio telescope soon after the identification of the source of X-ray pulsations was reported in order to search for corresponding radio pulsations. We used a continuous 6.4 hr observation with a 256 MHz bandwidth centered at 1390 MHz using the center beam of the Parkes multibeam receiver. In the subsequent data analysis, which included a folding search, a Fourier search, a fast-folding algorithm search, and a single pulse search, no pulsed signals were found for trial dispersion measures (DMs) between 0 and 800 pc cm -3 . This DM range easily encompasses the expected values for sources in the SMC. We place an upper limit of ∼45 mJy kpc 2 on the luminosity of periodic radio emission from XTE J0103-728 at the epoch of our observation, and we compare this limit to a range of luminosities measured for PSR B1259-63, the only Be/X-ray binary currently known to emit radio pulses. We also compare our limit to the radio luminosities of neutron stars having similarly long spin periods to XTE J0103-728. Since the radio pulses from PSR B1259-63 are eclipsed and undetectable during the portion of the orbit near periastron, repeated additional radio search observations of XTE J0103-728 may be valuable if it is undergoing similar eclipsing and if such observations are able to sample the orbital phase of this system well.

  4. Phase-contrast X-ray imaging using an X-ray interferometer for biological imaging

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi; Koyama, Ichiro [Tokyo Univ., Dept. of Applied Physics, Tokyo (Japan); Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Inst. of Clinical Medicine, Tsukuba, Ibaraki (Japan); Yoneyama, Akio [Hitachi Ltd., Advanced Research Laboratory, Saitama (Japan)

    2002-04-01

    The potential of phase-contrast X-ray imaging using an X-ray interferometer is discussed comparing with other phase-contrast X-ray imaging methods, and its principle of contrast generation is presented including the case of phase-contrast X-ray computed tomography. The status of current instrumentation is described and perspectives for practical applications are discussed. (author)

  5. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro [Kyoto Second Red Cross Hospital, Kyoto (Japan)

    2012-02-15

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  6. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    International Nuclear Information System (INIS)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro

    2012-01-01

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  7. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  8. Interventional devascularization for the treatment of upper gastrointestinal hemorrhage in patients with portal hypertension: mid-term to long-term results

    International Nuclear Information System (INIS)

    Liu Wei; Chen Hongbo; Chen Gensheng; Zhang Weiping; Zheng Qun

    2009-01-01

    Objective: To assess the mid-term to long-term results of interventional devascularization in the treatment of upper gastrointestinal hemorrhage in patients with portal hypertension. Methods: Interventional devascularization was performed in 49 patients with upper gastrointestinal hemorrhage due to portal hypertension caused by cirrhosis. The patients were followed up for 6-36 months after the procedure. The recurrence of bleeding, postoperative complications and outcome. were observed and analyzed. Results: The technical success rate was 98.0% (48 / 49) and the mortality was 2%. The re-bleeding occurrence rate at 1, 6, 12, 24 and 36 months was 0%, 2.1%, 12.5%, 24.5% and 27.9%, respectively. The causes of re-bleeding included re-rupture of varicose vein (25%), portal hypertensive gastropathy (58.3%) and peptic ulcer (16.7%). Conclusion: The interventional devascularization is a simple, safe and effective method for the treatment of upper gastrointestinal hemorrhage due to portal hypertension. (authors)

  9. Development of X-ray excitable luminescent probes for scanning X-ray microscopy

    International Nuclear Information System (INIS)

    Moronne, M.M.

    1999-01-01

    Transmission soft X-ray microscopy is now capable of achieving resolutions that are typically 5 times better than the best-visible light microscopes. With expected improvements in zone plate optics, an additional factor of two may be realized within the next few years. Despite the high resolution now available with X-ray microscopes and the high X-ray contrast provided by biological molecules in the soft X-ray region (λ=2-5 nm), molecular probes for localizing specific biological targets have been lacking. To circumvent this problem, X-ray excitable molecular probes are needed that can target unique biological features. In this paper we report our initial results on the development of lanthanide-based fluorescent probes for biological labeling. Using scanning luminescence X-ray microscopy (SLXM, Jacobsen et al., J. Microscopy 172 (1993) 121-129), we show that lanthanide organo-polychelate complexes are sufficiently bright and radiation resistant to be the basis of a new class of X-ray excitable molecular probes capable of providing at least a fivefold improvement in resolution over visible light microscopy. Lanthanide probes, able to bind 80-100 metal ions per molecule, were found to give strong luminescent signals with X-ray doses exceeding 10 8 Gy, and were used to label actin stress fibers and in vitro preparations of polymerized tubulin. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  10. Haemosuccus pancreaticus due to true splenic artery aneurysm: a rare cause of massive upper gastrointestinal bleeding

    Directory of Open Access Journals (Sweden)

    MK Roy

    2010-07-01

    Full Text Available “Haemosuccus pancreaticus” is an unusual cause of severe upper gastrointestinal bleeding and results from rupture of splenic artery aneurysm into the pancreatic duct. More commonly, it is a pseudoaneurysm of the splenic artery which develops as sequelae of pancreatitis. However, true aneurysm of the splenic artery without pancreatitis has rarely been incriminated as the etiologic factor of this condition. Owing to the paucity of cases and limited knowledge about the disease, diagnosis as well as treatment become challenging. Here we describe a 60-year-old male presenting with severe recurrent upper gastrointestinal bleeding and abdominal pain, which, after considerable delay, was diagnosed to be due to splenic artery aneurysm. Following an unsuccessful endovascular embolisation, the patient was cured by distal pancreatectomy and ligation of aneurysm.

  11. Projection-type X-ray microscope based on a spherical compound refractive X-ray lens

    OpenAIRE

    Dudchik, Yu. I.; Gary, C. K.; Park, H.; Pantell, R. H.; Piestrup, M. A.

    2007-01-01

    New projection- type X-ray microscope with a compound refractive lens as the optical element is presented. The microscope consists of an X-ray source that is 1-2 mm in diameter, compound X-ray lens and X-ray camera that are placed in-line to satisfy the lens formula. The lens forms an image of the X-ray source at camera sensitive plate. An object is placed between the X-ray source and the lens as close as possible to the source, and the camera shows a shadow image of the object. Spatial resol...

  12. The glasgow blatchford score is the most accurate assessment of patients with upper gastrointestinal hemorrhage

    DEFF Research Database (Denmark)

    Laursen, Stig Borbjerg; Hansen, Jane Møller; Schaffalitzky de Muckadell, Ove B

    2012-01-01

    Risk scoring systems are used increasingly to assess patients with upper gastrointestinal hemorrhage (UGIH). There have been comparative studies to identify the best system, but most have been retrospective and included small sample sizes, few patients with severe bleeding and with low mortality...

  13. Efficacy of deep biopsy for subepithelial lesions in the upper gastrointestinal tract.

    Science.gov (United States)

    Vaicekauskas, Rolandas; Stanaitis, Juozas; Valantinas, Jonas

    2016-01-01

    Accurate diagnosis of subepithelial lesions (SELs) in the gastrointestinal tract depends on a variety of methods: endoscopy, endoscopic ultrasound and different types of biopsy. Making an error-free diagnosis is vital for the subsequent application of an appropriate treatment. To evaluate the efficacy of deep biopsy via the endoscopic submucosal dissection (ESD) technique for SELs in the upper gastrointestinal tract. It was a case series study. Deep biopsy via the ESD technique was completed in 38 patients between November 2012 and October 2014. Thirty-eight SELs in the upper gastrointestinal tract of varying size (very small ≤ 1 cm, small 1-2 cm and large ≥ 2 cm) by means of the ESD technique after an incision with an electrosurgical knife of the overlying layers and revealing a small part of the lesion were biopsied under direct endoscopic view. Deep biopsy via the ESD technique was diagnostic in 28 of 38 patients (73.3%; 95% CI: 59.7-89.7%). The diagnostic yield for SELs with a clear endophytic shape increased to 91.3%. An evident endophytic appearance of a subepithelial lesion, the mean number of biopsied samples (6.65 ±1.36) and the total size in length of all samples per case (19.88 ±8.07 mm) were the main criteria influencing the positiveness of deep biopsy in the diagnostic group compared to the nondiagnostic one (p = 0.001; p = 0.025; p = 0.008). Deep biopsy via the ESD technique is an effective and safe method for the diagnosis of SELs especially with a clear endophytic appearance in a large number of biopsied samples.

  14. X-Ray Lasers 2016

    CERN Document Server

    Bulanov, Sergei; Daido, Hiroyuki; Kato, Yoshiaki

    2018-01-01

    These proceedings comprise a selection of invited and contributed papers presented at the 15th International Conference on X-Ray Lasers (ICXRL 2016), held at the Nara Kasugano International Forum, Japan, from May 22 to 27, 2016. This conference was part of an ongoing series dedicated to recent developments in the science and technology of x-ray lasers and other coherent x-ray sources with additional focus on supporting technologies, instrumentation and applications.   The book showcases recent advances in the generation of intense, coherent x-rays, the development of practical devices and their applications across a wide variety of fields. It also discusses emerging topics such as plasma-based x-ray lasers, 4th generation accelerator-based sources and higher harmonic generations, as well as other x-ray generation schemes.

  15. PERFORATION AS A COMPLICATION OF THE DIAGNOSTIC UPPER AND LOWER ENDOSCOPY OF THE GASTROINTESTINAL TRACT

    Directory of Open Access Journals (Sweden)

    Ivailo P. Vazharov

    2012-08-01

    Full Text Available Purpose: The purpose of this examination is to evaluate the risk of perforation during endoscopy of upper and lower gastrointestinal tract.Patients and methods used: 1210 diagnostic gastroduodenoscopies and 412 colonoscopies of hospitalized patients were performed by two experienced endoscopists for the period March 2007 – March 2012 at MHAT Varna, MMA. The endoscopies were performed without premedication and sedation. The patients were examined for complications of the procedure during and after the endoscopy. One of the most serious complications is the perforation of the oesophagus, stomach or the large intestine.Results: We had no perforations caused by the examination during the 1210 upper endoscopies performed. We had 2 perforations (0,48% from the 412 colonoscopies performed, which were treated successfully surgically.Conclusions: The perforation is a rare but serious complication of the endoscopy of gastrointestinal tract, which can be healed completely.

  16. The Mapping X-ray Fluorescence Spectrometer (MapX)

    Science.gov (United States)

    Sarrazin, P.; Blake, D. F.; Marchis, F.; Bristow, T.; Thompson, K.

    2017-12-01

    Many planetary surface processes leave traces of their actions as features in the size range 10s to 100s of microns. The Mapping X-ray Fluorescence Spectrometer (MapX) will provide elemental imaging at 100 micron spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or biological features can be imaged and interpreted in ancient rocks on planetary bodies and planetesimals. MapX is an arm-based instrument positioned on a rock or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample with X-rays or alpha-particles / gamma-rays, resulting in sample X-ray Fluorescence (XRF). X-rays emitted in the direction of an X-ray sensitive CCD imager pass through a 1:1 focusing lens (X-ray micro-pore Optic (MPO)) that projects a spatially resolved image of the X-rays onto the CCD. The CCD is operated in single photon counting mode so that the energies and positions of individual X-ray photons are recorded. In a single analysis, several thousand frames are both stored and processed in real-time. Higher level data products include single-element maps with a lateral spatial resolution of 100 microns and quantitative XRF spectra from ground- or instrument- selected Regions of Interest (ROI). XRF spectra from ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. When applied to airless bodies and implemented with an appropriate radioisotope source for alpha-particle excitation, MapX will be able to analyze biogenic elements C, N, O, P, S, in addition to the cations of the rock-forming elements >Na, accessible with either X-ray or gamma-ray excitation. The MapX concept has been demonstrated with a series of lab-based prototypes and is currently under refinement and TRL maturation.

  17. Combined optic system based on polycapillary X-ray optics and single-bounce monocapillary optics for focusing X-rays from a conventional laboratory X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xuepeng; Liu, Zhiguo [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi, E-mail: stx@bnu.edu.cn [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Yi, Longtao; Sun, Weiyuan; Li, Fangzuo; Jiang, Bowen [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Ma, Yongzhong [Center for Disease Control and Prevention of Beijing, Beijing 100013 (China); Ding, Xunliang [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2015-12-01

    Two combined optic systems based on polycapillary X-ray optics and single-bounce monocapillary optics (SBMO) were designed for focusing the X-rays from a conventional laboratory X-ray source. One was based on a polycapillary focusing X-ray lens (PFXRL) and a single-bounce ellipsoidal capillary (SBEC), in which the output focal spot with the size of tens of micrometers of the PFXRL was used as the “virtual” X-ray source for the SBEC. The other system was based on a polycapillary parallel X-ray lens (PPXRL) and a single-bounce parabolic capillary (SBPC), in which the PPXRL transformed the divergent X-ray beam from an X-ray source into a quasi-parallel X-ray beam with the divergence of sever milliradians as the incident illumination of the SBPC. The experiment results showed that the combined optic systems based on PFXRL and SBEC with a Mo rotating anode X-ray generator with the focal spot with a diameter of 300 μm could obtain a focal spot with the total gain of 14,300 and focal spot size of 37.4 μm, and the combined optic systems based on PPXRL and SBPC with the same X-ray source mentioned above could acquire a focal spot with the total gain of 580 and focal spot size of 58.3 μm, respectively. The two combined optic systems have potential applications in micro X-ray diffraction, micro X-ray fluorescence, micro X-ray absorption near edge structure, full field X-ray microscopes and so on.

  18. Wavelength dispersive X-ray absorption fine structure imaging by parametric X-ray radiation

    International Nuclear Information System (INIS)

    Inagaki, Manabu; Sakai, Takeshi; Sato, Isamu; Hayakawa, Yasushi; Nogami, Kyoko; Tanaka, Toshinari; Hayakawa, Ken; Nakao, Keisuke

    2008-01-01

    The parametric X-ray radiation (PXR) generator system at Laboratory for Electron Beam Research and Application (LEBRA) in Nihon University is a monochromatic and coherent X-ray source with horizontal wavelength dispersion. The energy definition of the X-rays, which depends on the horizontal size of the incident electron beam on the generator target crystal, has been investigated experimentally by measuring the X-ray absorption near edge structure (XANES) spectra on Cu and CuO associated with conventional X-ray absorption imaging technique. The result demonstrated the controllability of the spectrum resolution of XANES by adjusting of the horizontal electron beam size on the target crystal. The XANES spectra were obtained with energy resolution of several eV at the narrowest case, which is in qualitative agreement with the energy definition of the PXR X-rays evaluated from geometrical consideration. The result also suggested that the wavelength dispersive X-ray absorption fine structure measurement associated with imaging technique is one of the promising applications of PXR. (author)

  19. 67Ga scanning and upper gastrointestinal series for gastric lymphomas

    International Nuclear Information System (INIS)

    Ichiya, Y.; Oshiumi, Y.; Kamoi, I.; Imoto, T.; Shimoda, Y.; Kitagawa, S.; Matsuura, K.

    1982-01-01

    67 Ga scanning and upper gastrointestinal (UGI) series were performed in 13 patients with gastric lymphomas before any treatment was initiated. Seven of these patients also underwent both examinations after completing chemotherapy and/or radiation therapy. Prior to treatment, all 13 patients had abnormalities on the UGI examination, and 12 of them had abnormalities on the 67 Ga scans. In 6 patients, more extensive gastric abnormalities were demonstrated by 67 Ga scanning than by UGI examination. Although persistent 67 Ga uptake after treatment was indicative of relatively poor therapeutic response, lack of uptake did not always indicate a good response to treatment

  20. Laparoscopy in the treatment of a giant true epiphrenic diverticulum with migration of the gastrointestinal anastomosis staples

    International Nuclear Information System (INIS)

    AbuDaff, Nasr S.; AbuDaff, Saleh N.; Rubayaan, Abdulrahman; AbuShaaban, Azam

    2009-01-01

    Our case is a 62-year-old diabetic man with a long-standing history of regurgitation, halitosis, recurrent chest infection, and most recently upper gastro-intestinal bleeding. He was diagnosed 10 years earlier with an epiphrenic esophageal diverticulum, and also has a family history of this condition. Barium study revealed a 10x10 cm epiphrenic diverticula with a 4 cm neck, the lower margin of the opening lying 6 cm from the gastro-esophageal junction. Endoscopy confirmed the x-ray findings, and motility studies were within normal limits. The patient underwent laparoscopic excision of the diverticulum via the trans-abdominal approach. Histopathological examination revealed this diverticulum to be of the true type. (author)

  1. Treatment of Postoperative Leaks of the Upper Gastrointestinal Tract with Colonic Self-Expandable Metal Stents.

    Science.gov (United States)

    Sousa, Paula; Castanheira, António; Martins, Diana; Pinho, Juliana; Araújo, Ricardo; Cancela, Eugénia; Ministro, Paula; Silva, Américo

    2017-07-01

    The use of self-expandable metal stents (SEMS) for the treatment of postoperative leaks of the upper gastrointestinal tract is already established. However, there are discrepancies between the relatively small caliber of the esophageal stents available and the postsurgical luminal size, which may determine an inadequate juxtaposition. As colonic stents have a bigger diameter, they might be more adequate. Additionally, stents with a larger diameter might have a lower risk of migration. The aim of this study was to evaluate the efficacy and complications associated with the use of colonic fully covered SEMS (FSEMS) in the treatment of postoperative leaks in critical patients. All patients with postoperative leaks of the upper gastrointestinal tract treated with colonic stents (Hanarostent® CCI) between 2010 and 2013 were retrospectively included. Four patients with postoperative leaks were treated with colonic SEMS. The underlying surgeries were a gastric bypass, an esophagogastrectomy for Boerhaave syndrome, a primary repair of esophagopleural fistula due to Boerhaave syndrome, and an esophagectomy due to esophageal cancer. The leaks were detected on average 17 days after the initial surgery. All patients needed admission to a critical care unit after index surgery. Stent placement was technically feasible in all patients. The median residence time of the stents was 7 weeks, and no complications were verified when they were removed. There were no cases of stent migration. The treatment was successful in all patients, with complete healing of the leaks. The placement of colonic FSEMS seems to be successful and safe in the treatment of postoperative leaks of the upper gastrointestinal tract.

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  7. Angiography and the gastrointestinal bleeder

    International Nuclear Information System (INIS)

    Baum, S.

    1982-01-01

    The role of angiography in the diagnosis and treatment of gastrointestinal hemorrhage is discussed. Three categories of gastrointestinal bleeding are considered: upper gastrointestinal bleeding due to gastroesophageal varices, upper gastrointestinal bleeding of arterial or capillary origin, and lower gastrointestinal bleeding. The advantages and disadvantages of angiography are compared with those of radionuclide scanning and endoscopy or colonoscopy. It is anticipated that, as radionuclide scans are more widely employed, angiography will eventually be performed only in those patients with positive scans

  8. Einstein Observatory magnitude-limited X-ray survey of late-type giant and supergiant stars

    Science.gov (United States)

    Maggio, A.; Vaiana, G. S.; Haisch, B. M.; Stern, R. A.; Bookbinder, J.

    1990-01-01

    Results are presented of an extensive X-ray survey of 380 giant and supergiant stars of spectral types from F to M, carried out with the Einstein Observatory. It was found that the observed F giants or subgiants (slightly evolved stars with a mass M less than about 2 solar masses) are X-ray emitters at the same level of main-sequence stars of similar spectral type. The G giants show a range of emissions more than 3 orders of magnitude wide; some single G giants exist with X-ray luminosities comparable to RS CVn systems, while some nearby large G giants have upper limits on the X-ray emission below typical solar values. The K giants have an observed X-ray emission level significantly lower than F and F giants. None of the 29 M giants were detected, except for one spectroscopic binary.

  9. Severe upper gastrointestinal bleeding in extraluminal diverticula in the third part of the duodenum

    DEFF Research Database (Denmark)

    Wilhelmsen, Michael; Andersen, Johnny Fredsbo; Lauritsen, Morten Laksafoss

    2014-01-01

    The successful management of upper gastrointestinal (GI) bleeding requires identification of the source of bleeding and when this is achieved the bleeding can often be treated endoscopically. However, the identification of the bleeding can be challenging due to the location of the bleeding...... or technical aspects. Therefore it might be necessary to use other measures than endoscopy such as CT angiography. Duodenal diverticula is a rare cause of upper GI bleeding and can be challenging to diagnose as they often require specialised endoscopy procedures such as endoscopy with a side-viewing scope....... This case describes the first successful management of this rare condition with an upper GI endoscopy with a colonoscope and afterwards intravascular coiling....

  10. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  11. Effectiveness comparison of endoscopic methods of non-varicose upper gastrointestinal bleeding treatment

    OpenAIRE

    Kujawski, Krzysztof; Stasiak, Magdalena; Stępień, Mariusz; Rysz, Jacek

    2010-01-01

    Introduction In every case of upper gastrointestinal bleeding suspicion, an endoscopic examination ought to be performed as a matter of urgency. Finding active bleeding, a visible non-bleeding vessel or a lesion with an adherent clot should be followed by application of an available method of endoscopic therapy. The aim of the study was to compare the effectiveness of various endoscopic treatment techniques such as epinephrine injections, coagulation methods and mechanical methods in the trea...

  12. Helicobacter pylori and risk of upper gastrointestinal bleeding among users of selective serotonin reuptake inhibitors

    DEFF Research Database (Denmark)

    Dall, Michael; Schaffalitzky de Muckadell, Ove B; Møller Hansen, Jane

    2011-01-01

    A number of studies have reported a possible association between use of selective serotonin reuptake inhibitors (SSRIs) and serious upper gastrointestinal bleeding (UGB). We conducted this case-control study to assess if Helicobacter pylori (H. pylori) potentiates the risk of serious UGB in SSRI ...

  13. Endoscopic findings in patients with upper gastrointestinal bleeding clinically classified into three risk groups prior to endoscopy

    OpenAIRE

    Tammaro, Leonardo; Paolo, Maria Carla Di; Zullo, Angelo; Hassan, Cesare; Morini, Sergio; Caliendo, Sebastiano; Pallotta, Lorella

    2008-01-01

    AIM: To investigate in a prospective study whether a simplified clinical score prior to endoscopy in upper gastrointestinal bleeding (UGIB) patients was able to predict endoscopic findings at urgent endoscopy.

  14. Upper Gastrointestinal Disorders in Children with End -Stage Renal Disease

    Directory of Open Access Journals (Sweden)

    Esfahani S.T

    2009-04-01

    Full Text Available This study was undertaken to define the prevalence of the upper Gastrointestinal (GI lesions, dyspeptic symptoms, H.pylori infection, and the impact of duration of dialysis on upper GI symptoms and lesions of children with End-stage renal disease. We studied 69 children with ESRD who were under regular hemodialysis therapy in our department. The age of the patients were between 4-18 years (mean: 11.3. 57(82.6% of 69 patients had GI symptoms and 12(17.4% were symptom free, the prevalence of each symptom in 57 symptomatic children was as follows: anorexia 48(84.2%, nausea/vomiting 39 (68.4%, belching/heartburn 20(35%, abdominal distention 15(26.3%, and epigastric pain 8(14%. 65(92.4% of 69 patients with ESRD had pathologic lesions and the most common lesion was gastritis .There was no case of gastric angiodysplasia in our patients. 15(21.7% of 69 patients had H. pylori infection. The prevalence of H.pylori infection in non-uremic children with upper GI symptoms is about 27% in our pediatric gastroenterology department, so there was no significant difference in prevalence of H.pylori infection between uremic and non-uremic children in our study (p value = 0.4735. There was no significant relationship between duration of dialysis and dyspeptic symptoms or upper GI lesions (p values were 0.8775 and 0.7435, respectively. Conclusions: Upper GI disorders are very common in children with ESRD, even when they have no upper GI symptoms, the most common lesion is gastritis. The prevalence of H.pylori infection is not different between children with ESRD and non-uremic children with upper GI symptoms, and duration of hemodialysis therapy has no significant effect on prevalence of GI symptoms and lesions.

  15. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90° Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ~ 300 fs, 30 keV (0.4 Å) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been demonstrated as a

  16. Ultrashort X-ray pulse science

    International Nuclear Information System (INIS)

    Chin, A.H.; Lawrence Berkeley National Lab., CA

    1998-01-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90 o Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ∼ 300 fs, 30 keV (0.4 (angstrom)) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been

  17. X-RAY AND GAMMA-RAY FLASHES FROM TYPE Ia SUPERNOVAE?

    International Nuclear Information System (INIS)

    Hoeflich, Peter; Schaefer, Bradley E.

    2009-01-01

    and Transient Source Experiment (BATSE) about 12.9 ± 3.6 nearby SNe Ia should have been detected, but only 0.8 ± 0.7 non-coincidental matches have been found. With the High Energy Transient Explorer (HETE) and Swift satellites, we expect to see 5.6 ± 1.3 SN-Ia flashes from known nearby SNe Ia but, yet, no SN-Ia flashes were detected. With the trigger thresholds for these experiments and the upper limits on the SN-Ia distances, we show that the bolometric peak luminosity of SN-Ia flashes must be less ∼10 46 erg s -1 . Our observational limit is several orders-of-magnitude smaller than the peak luminosities predicted for both the early flashes. We attribute this difference to the absorption of the X- and γ-rays by the accretion disk of large-scale height or common envelope that would be smothering the WD.

  18. Outcome of index upper gastrointestinal endoscopy in patients presenting with dysphagia in a tertiary care hospital-A 10 years review

    Directory of Open Access Journals (Sweden)

    Fielding John W

    2007-11-01

    Full Text Available Abstract Background Patients with malignant tumours of the upper gastrointestinal tract tumours exhibit important alarm symptoms such as dysphagia that warrant clinical investigations. An endoscopic examination of the upper gastrointestinal tract will be required in most cases. This study evaluates the diagnostic potential of index endoscopy in a random population of patients with dysphagia. Methods This is a retrospective analysis of prospectively collected data over 10 years. Patients with previous endoscopic evaluation or upper gastrointestinal pathology were excluded from the study. Data was analysed to see the number and frequency of abnormal findings in upper gastrointestinal tract, and their significance in relation to the presenting symptoms. Results Total number of index endoscopies was 13, 881. 913 patients were included in the study including 465 males (age range: 17–92 years, median: 55 years and 448 females (age range: 18–100, median: 59 years, with male to female ratio of 1.04: 1. Oesophagus was abnormal in 678 cases (74% and biopsies were taken in 428 patients (47%. Superficial oesophagitis, Barrett's oesophagus, oesophageal cancer, and oesophageal ulcer were main histological findings. Age more than 50 years and weight loss were significant predictors of oesophageal cancer (p Conclusion OGD is an effective initial investigation to assess patients with dysphagia, especially males above the age of 50 years. Patients may be started on treatment or referred for further investigations, for example, a barium meal in the absence of any anatomical abnormality.

  19. A Case of an Upper Gastrointestinal Bleeding Due to a Ruptured Dissection of a Right Aortic Arch

    International Nuclear Information System (INIS)

    Born, Christine; Forster, Andreas; Rock, Clemens; Pfeifer, Klaus-Juergen; Rieger, Johannes; Reiser, Maximilian

    2003-01-01

    We report a case of severe upper gastrointestinal hemorrhage with a rare underlying cause. The patient was unconscious when he was admitted to the hospital. No chest radiogram was performed. Routine diagnostic measures, including endoscopy, failed to reveal the origin of the bleeding, which was believed to originate from the esophagus secondary to a peptic ulcer or varices. Exploratory laparotomy added no further information, but contrast-enhanced multislice computed tomography (MSCT) of the chest showed dextroposition of the widened aortic arch with a ruptured type-B dissection and a consecutive aorto-esophageal fistula (AEF). The patient died on the day of admission. Noninvasive MSCT angiography gives rapid diagnostic information on patients with occult upper gastrointestinal bleeding and should be considered before more invasive conventional angiography or surgery

  20. Wide-area phase-contrast X-ray imaging using large X-ray interferometers

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi E-mail: momose@exp.t.u-tokyo.ac.jp; Takeda, Tohoru; Yoneyama, Akio; Koyama, Ichiro; Itai, Yuji

    2001-07-21

    Large X-ray interferometers are developed for phase-contrast X-ray imaging aiming at medical applications. A monolithic X-ray interferometer and a separate one are studied, and currently a 25 mmx20 mm view area can be generated. This paper describes the strategy of our research program and some recent developments.

  1. Wide-area phase-contrast X-ray imaging using large X-ray interferometers

    Science.gov (United States)

    Momose, Atsushi; Takeda, Tohoru; Yoneyama, Akio; Koyama, Ichiro; Itai, Yuji

    2001-07-01

    Large X-ray interferometers are developed for phase-contrast X-ray imaging aiming at medical applications. A monolithic X-ray interferometer and a separate one are studied, and currently a 25 mm×20 mm view area can be generated. This paper describes the strategy of our research program and some recent developments.

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-rays. top of page What does the equipment look like? The equipment typically used for bone x-rays consists of ... and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely available in emergency ...

  3. Material Discriminated X-Ray CT System by Using New X-Ray Imager with Energy Discriminate Function

    Directory of Open Access Journals (Sweden)

    Toru Aoki

    2008-04-01

    Full Text Available Material discriminated X-ray CT system has been constructed by using conventional X-ray tube (white X-ray source and photon-counting X-ray imager as an application with energy band detection. We have already reported material identify X-ray CT using K-shell edge method elsewhere. In this report the principle of material discrimination was adapted the separation of electron-density and atomic number from attenuation coefficient mapping in X-ray CT reconstructed image in two wavelength X-ray CT method using white X-ray source and energy discriminated X-ray imager by using two monochrome X-ray source method. The measurement phantom was prepared as four kinds material rods (Carbon(C, Iron(Fe, Copper(Cu, Titanium(Ti rods of 3mm-diameter inside an aluminum(Al rod of 20mm-diameter. We could observed material discriminated X-ray CT reconstructed image, however, the discrimination properties were not good than two monochrome X-ray CT method. This results was could be explained because X-ray scattering, beam-hardening and so on based on white X-ray source, which could not observe in two monochrome X-ray CT method. However, since our developed CdTe imager can be detect five energy-bands at the same time, we can use multi-band analysis to decrease the least square error margin. We will be able to obtain more high separation in atomic number mapping in X-ray CT reconstructed image by using this system.

  4. X-Pinch And Its Applications In X-ray Radiograph

    International Nuclear Information System (INIS)

    Zou Xiaobing; Wang Xinxin; Liu Rui; Zhao Tong; Zeng Naigong; Zhao Yongchao; Du Yanqiang

    2009-01-01

    An X-pinch device and the related diagnostics of x-ray emission from X-pinch were briefly described. The time-resolved x-ray measurements with photoconducting diodes show that the x-ray pulse usually consists of two subnanosecond peaks with a time interval of about 0.5 ns. Being consistent with these two peaks of the x-ray pulse, two point x-ray sources of size ranging from 100 μm to 5 μm and depending on cut-off x-ray photon energy were usually observed on the pinhole pictures. The x-pinch was used as x-ray source for backlighting of the electrical explosion of single wire and the evolution of X-pinch, and for phase-contrast imaging of soft biological objects such as a small shrimp and a mosquito.

  5. Guidelines for the diagnosis and treatment of acute non-variceal upper gastrointestinal bleeding (2015, Nanchang, China).

    Science.gov (United States)

    Bai, Yu; Li, Zhao Shen

    2016-02-01

    Acute non-variceal upper gastrointestinal bleeding (ANVUGIB) is one of the most common medical emergencies in China and worldwide. In 2009, we published the "Guidelines for the diagnosis and treatment of acute non-variceal upper gastrointestinal bleeding" for the patients in China; however, during the past years numerous studies on the diagnosis and treatment of ANVUGIB have been conducted, and the management of ANVUGIB needs to be updated. The guidelines were updated after the databases including PubMed, Embase and CNKI were searched to retrieve the clinical trials on the management of ANVUGIB. The clinical trials were evaluated for high-quality evidence, and the advances in definitions, diagnosis, etiology, severity evaluation, treatment and prognosis of ANVUGIB were carefully reviewed, the recommendations were then proposed. After several rounds of discussions and revisions among the national experts of digestive endoscopy, gastroenterology, radiology and intensive care, the 2015 version of "Guidelines for the diagnosis and treatment of acute non-variceal upper gastrointestinal bleeding" was successfully developed by the Chinese Journal of Internal Medicine, National Medical Journal of China, Chinese Journal of Digestion and Chinese Journal of Digestive Endoscopy. It shall be noted that although much progress has been made, the clinical management of ANVUGIB still needs further improvement and refinement, and high-quality randomized trials are required in the future. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  6. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  7. X-ray luminescent glasses

    International Nuclear Information System (INIS)

    Takahashi, T.; Yamada, O.

    1981-01-01

    X-ray luminescent glasses comprising a divalent cation such as an alkaline earth metal or other divalent cations such as pb, cd, or zn, and certain rare earth metaphosphates are suitable as vitreous, x-ray phosphors or x-ray luminescent glass fibers in an x-ray intensifying screen. The glasses have the composition n(Mo X p2o5)((1-y)tb2o3 X yce2o3 X 3p2o5) wherein N is greater than zero but less than or equal to 16, M is an alkaline earth metal or other divalent cation such as pb, cd, or zn, and Y is greater than or equal to zero but less than one

  8. X-ray electromagnetic application technology

    International Nuclear Information System (INIS)

    2011-01-01

    The investigating committee aimed at research on electromagnetic fields in functional devices and X-ray fibers for efficient coherent X-ray generation and their material science, high-precision manufacturing, particularly for X-ray electromagnetic application technology from January 2006 to December 2008. In this report, we describe our research results, in particular, on the topics of synchrotron radiation and free-electron laser, Saga Synchrotron Project, X-ray waveguides and waveguide-based lens-less hard-X-ray imaging, X-ray nanofocusing for capillaries and zone plates, dispersion characteristics in photonics crystal consisting of periodic atoms for nanometer waveguides, electromagnetic characteristics of grid structures for scattering fields of nano-meter electromagnetic waves and X-rays, FDTD parallel computing of fundamental scattering and attenuation characteristics of X-ray for medical imaging diagnosis, orthogonal relations of electromagnetic fields including evanescent field in dispersive medium. (author)

  9. Legal directives in the X-ray regulation for the field of X-ray diagnostics

    International Nuclear Information System (INIS)

    Huhn, Walter

    2012-01-01

    The operation of each X-ray device is subject to the requirements of the X-ray regulations (RoeV); for different operational modes or applications like curative diagnostics, X-ray serial examinations, X-ray radiotherapy and teleradiology different directives exist and have to be respected. The report discusses the issues licensing and notification procedures, radiation protection representative, requirements for the commissioning (teleradiology, serial X.ray examinations), technical qualification and radiation protection knowledge of physicians, technical qualification of the assistant personnel.

  10. Giant Brunner’s Gland Hamartoma of the Duodenal Bulb Presenting with Upper Gastrointestinal Bleeding and Obstruction

    Directory of Open Access Journals (Sweden)

    Ju Hyoung Lee

    2016-11-01

    Full Text Available Brunner’s gland hamartomas are small benign lesions that are most commonly found in the bulb of the duodenum. They are very uncommon, and most are found incidentally during upper gastrointestinal series or esophagogastroduodenoscopy. The lesions tend to be asymptomatic, but patients may present with symptoms of duodenal obstruction or hemorrhage secondary to ulceration. Histologically, a Brunner's gland hamartoma consists of the components of Brunner's gland cells, as well as glandular, adipose and muscle cells. In this study, we report the case of a 30-year-old man who presented with upper gastrointestinal bleeding and obstructive symptoms due to a giant Brunner's gland hamartoma in the duodenal bulb. The hamartoma was successfully removed by endoscopic resection. No significant complications were observed. Microscopically, the lesion was found to be entirely composed of variable Brunner's glands and adipocytes.

  11. A study on the application of prone compression study for obese patients in upper gastrointestinal series

    International Nuclear Information System (INIS)

    Son, Soon Yong; Jung, Hong Ryang

    1999-01-01

    The aim of this study is to measure the application of prone compression study using compression paddle for obese patients in upper gastrointestinal series. Prone compression study using compression paddle was performed in fifty patients, who were not examined completely erect compression study for obesity. The radiographs of stomach were classified into the lower, middle, and high body, and then we gave five points included 'very poor', 'poor', 'suspicious', 'good', and 'complete' according to level of detection for area gastric and mucosal fold. Statistic analysis was performed using T-test and ANOVA, and confidence rate was fixed in 95%(P 0.05). As these results, the prone compression study in upper gastrointestinal series seem to be an useful study for obese patients, because it decreases pain and the feeling of uneasiness, and improve compression efficiency remarkably

  12. High-speed X-ray topography

    International Nuclear Information System (INIS)

    Eckers, W.; Oppolzer, H.

    1977-01-01

    The investigation of lattice defects in semiconductor crystals by conventional X-ray diffraction topography is very time-consuming. Exposure times can be reduced by using high-intensity X-rays and X-ray image intensifiers. The described system comprises a high-power rotating-anode X-ray tube, a remote-controlled X-ray topography camera, and a television system operating with an X-ray sensing VIDICON. System performance is demonstrated with reference to exploratory examples. The exposure time for photographic plates is reduced to 1/20 and for the X-ray TV system (resolution of the order of 30 μm) to 1/100 relative to that required when using a conventional topography system. (orig.) [de

  13. 13.1 micrometers hard X-ray focusing by a new type monocapillary X-ray optic designed for common laboratory X-ray source

    Science.gov (United States)

    Sun, Xuepeng; zhang, Xiaoyun; Zhu, Yu; Wang, Yabing; Shang, Hongzhong; Zhang, Fengshou; Liu, Zhiguo; Sun, Tianxi

    2018-04-01

    A new type of monocapillary X-ray optic, called 'two bounces monocapillary X-ray optics' (TBMXO), is proposed for generating a small focal spot with high power-density gain for micro X-ray analysis, using a common laboratory X-ray source. TBMXO is consists of two parts: an ellipsoidal part and a tapered part. Before experimental testing, the TBMXO was simulated by the ray tracing method in MATLAB. The simulated results predicted that the proposed TBMXO would produce a smaller focal spot with higher power-density gain than the ellipsoidal monocapillary X-ray optic (EMXO). In the experiment, the TBMXO performance was tested by both an optical device and a Cu target X-ray tube with focal spot of 100 μm. The results indicated that the TBMXO had a slope error of 57.6 μrad and a 13.1 μm focal spot and a 1360 gain in power density were obtained.

  14. Effects of X-ray tube parameters on thickness measure precision in X-ray profile gauge

    International Nuclear Information System (INIS)

    Miao Jichen; Wu Zhifang; Xing Guilai

    2011-01-01

    Instantaneous profile gauge technology has been widely used in metallurgy industry because it can on-line get the profile of steel strip. It has characters of high measure precision and wide measure range, but the X-ray tube parameters only can be set few different values during measurement. The relations of thickness measure precision and X-ray tube current, X-ray tube voltage were analyzed. The results show that the X-ray tube current affects the thickness measure precision and the X-ray tube voltage determines the thickness measure range. The method of estimating the X-ray current by thickness measure precision was provided in the end. This method is the base of X-ray source selection and X-ray source parameter's setting in the instantaneous profile gauge. (authors)

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  16. X-Ray Exam: Hip

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What It Is Why ... You Have Questions Print What It Is A hip X-ray is a safe and painless test ...

  17. X-Ray Exam: Ankle

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What It Is Why ... You Have Questions Print What It Is An ankle X-ray is a safe and painless test ...

  18. HST spectrum and timing of the ultracompact X-ray binary candidate 47 Tuc X9

    Science.gov (United States)

    Tudor, V.; Miller-Jones, J. C. A.; Knigge, C.; Maccarone, T. J.; Tauris, T. M.; Bahramian, A.; Chomiuk, L.; Heinke, C. O.; Sivakoff, G. R.; Strader, J.; Plotkin, R. M.; Soria, R.; Albrow, M. D.; Anderson, G. E.; van den Berg, M.; Bernardini, F.; Bogdanov, S.; Britt, C. T.; Russell, D. M.; Zurek, D. R.

    2018-05-01

    To confirm the nature of the donor star in the ultracompact X-ray binary candidate 47 Tuc X9, we obtained optical spectra (3000-10 000 Å) with the Hubble Space Telescope / Space Telescope Imaging Spectrograph. We find no strong emission or absorption features in the spectrum of X9. In particular, we place 3σ upper limits on the H α and He II λ4686 emission line equivalent widths - EWH α ≲ 14 Å and -EW_{He {II}} ≲ 9 Å, respectively. This is much lower than seen for typical X-ray binaries at a similar X-ray luminosity (which, for L_2-10 keV ≈ 10^{33}-10^{34} erg s-1 is typically - EWH α ˜ 50 Å). This supports our previous suggestion, by Bahramian et al., of an H-poor donor in X9. We perform timing analysis on archival far-ultraviolet, V- and I-band data to search for periodicities. In the optical bands, we recover the 7-d superorbital period initially discovered in X-rays, but we do not recover the orbital period. In the far-ultraviolet, we find evidence for a 27.2 min period (shorter than the 28.2 min period seen in X-rays). We find that either a neutron star or black hole could explain the observed properties of X9. We also perform binary evolution calculations, showing that the formation of an initial black hole/ He-star binary early in the life of a globular cluster could evolve into a present-day system such as X9 (should the compact object in this system indeed be a black hole) via mass-transfer driven by gravitational wave radiation.

  19. Shield device for controlling the dose of x-rays applied in an x-ray machine

    International Nuclear Information System (INIS)

    Charrier, P.

    1983-01-01

    This invention provides an improved shield for use with an x-ray machine. The shield can control the dose of x-rays applied by the machine in different areas without affecting the power of the x-rays. This is achieved with a shield especially designed and positioned to intercept with x-rays for longer or shorter periods in different areas during the taking of the picture, but not for the whole period of time necessary for taking this picture. Each area of the subject being x-rayed is exposed to full power x-rays. However, owing to the shield, the areas that require smaller dose receive these full power x-rays for a shorter portion of the time required to take the picture while the other areas that require larger dose of x-rays, receive the full power x-rays for a longer portion of the full period of time required to take the picture. To ensure this differential exposure, the shield is placed through the path of the x-rays and rotated about an axis which is generally transverse to the direction of travel of the x-rays to cut out some of said x-rays for different portions of the period of time necessary for taking the picture. The shield is preferably shaped to intercept x-rays for a longer period in some areas than in others depending on the required doses. A plurality of differently shaped shields can be provided to suit different picture taking situations

  20. X-Ray Exam: Cervical Spine

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Cervical Spine KidsHealth / For Parents / X-Ray ... MRI): Lumbar Spine Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  1. Differences of X-ray exposure between X-ray diagnostics with a conventional X-ray screen-system and with an image-intensifier-television-unit

    International Nuclear Information System (INIS)

    Loehr, H.; Vogel, H.; Reinhart, J.; Jantzen, R.

    1977-01-01

    During X-ray diagnostics of patients in the II. Medizinische Poliklinik the X-ray exposure was determined. It corresponded to the data described in literature. Two groups were compared: 518 patients examined with a conventional X-ray screen-system and 642 patients examined with an image-intensifier-television-system. The results demonstrated that with exception of thoracical X-ray examination the replacing of the old system by the television system brought a remarkable increase of the X-ray exposure. The doses depended of the patients constitution to a high degree. (orig.) [de

  2. Congenital diaphragmatic hernia with gastrointestinal symptomatology

    International Nuclear Information System (INIS)

    Siroka, M.; Bilicky, J.; Hernesniemi, B.

    2014-01-01

    The authors report a case of 6-week-old baby boy with congenital diaphragmatic hernia(CDH). He presented with nonspecific gastrointestinal symptoms. CDH is commonly manifested by nonspecific respiratory problems. The symptoms of CDH in older infants are atypical and misleading. Children may have only gastrointestinal problems even the acute abdomen. In our case, the ultrasound examination of abdomen did not detect the exact cause of vomiting and intolerance of oral intake, but the explanation has brought classic chest X-ray. (author)

  3. Applications of phase-contrast x-ray imaging to medicine using an x-ray interferometer

    Science.gov (United States)

    Momose, Atsushi; Yoneyama, Akio; Takeda, Tohoru; Itai, Yuji; Tu, Jinhong; Hirano, Keiichi

    1999-10-01

    We are investigating possible medical applications of phase- contrast X-ray imaging using an X-ray interferometer. This paper introduces the strategy of the research project and the present status. The main subject is to broaden the observation area to enable in vivo observation. For this purpose, large X-ray interferometers were developed, and 2.5 cm X 1.5 cm interference patterns were generated using synchrotron X-rays. An improvement of the spatial resolution is also included in the project, and an X-ray interferometer designed for high-resolution phase-contrast X-ray imaging was fabricated and tested. In parallel with the instrumental developments, various soft tissues are observed by phase- contrast X-ray CT to find correspondence between the generated contrast and our histological knowledge. The observation done so far suggests that cancerous tissues are differentiated from normal tissues and that blood can produce phase contrast. Furthermore, this project includes exploring materials that modulate phase contrast for selective imaging.

  4. X-ray spectral meter of high voltages for X-ray apparatuses

    International Nuclear Information System (INIS)

    Zubkov, I.P.; Larchikov, Yu.V.

    1993-01-01

    Design of the X-ray spectral meter of high voltages (XRSMHV) for medical X-ray apparatuses permitting to conduct the voltage measurements without connection to current circuits. The XRSMHV consists of two main units: the detector unit based on semiconductor detector and the LP4900B multichannel analyzer (Afora, Finland). The XRSMYV was tested using the pilot plant based on RUM-20 X-ray diagnostic apparatus with high-voltage regulator. It was shown that the developed XRSMHV could be certify in the range of high constant voltages form 40 up to 120 kV with the basic relative error limits ±0.15%. The XRSMHV is used at present as the reference means for calibration of high-voltage medical X-ray equipment

  5. Discovery of X-Ray Emission from the Crab Pulsar at Pulse Minimum

    Science.gov (United States)

    Tennant, Allyn F.; Becker, Werner; Juda, Michael; Elsner, Ronald F.; Kolodziejczak, Jeffery J.; Murray, Stephen S.; ODell, Stephen L.; Paerels, Frits; Swartz, Douglas A.

    2001-01-01

    The Chandra X-Ray Observatory observed the Crab pulsar using the Low-Energy Transmission Grating with the High-Resolution Camera. Time-resolved zeroth-order images reveal that the pulsar emits X-rays at all pulse phases. Analysis of the flux at minimum - most likely non-thermal in origin - places an upper limit (T(sub infinity) < 2.1 MK) on the surface temperature of the underlying neutron star. In addition, analysis of the pulse profile establishes that the error in the Chandra-determined absolute time is quite small, -0.2 +/- 0.1 ms.

  6. Feasibility of using continuous X-ray to simulate cable response under X-ray environment

    International Nuclear Information System (INIS)

    Ma Liang; Zhou Hui; Cheng Yinhui; Wu Wei; Li Jinxi; Zhao Mo; Guo Jinghai

    2014-01-01

    The mechanism and simulating method of cable response induced by X-ray were researched, and the relationship of cable response irradiated by continuous and pulsed X-ray was analyzed. A one-dimension model of strip line irradiation response of X-ray was given, which includes the gap between cable shield and dielectric, and induced conductivity in cable dielectric. The calculation result using the model indicates that the cable responses of continuous and rectangular-pulsed X-ray have the similar current waveform and the same gap voltages. Therefore, continuous X-ray can be used to research some cable responses of pulsed X-ray irradiation under the mechanism described in the one-dimension model. (authors)

  7. X-ray cardiovascular examination apparatus

    International Nuclear Information System (INIS)

    1977-01-01

    An X-ray source is mounted in an enclosure for angulating longitudinally about a horizontal axis. An X-ray-permeable, patient-supporting table is mounted on the top of the enclosure for executing lateral and longitudinal movements. An X-ray image-receiving device such as an X-ray image intensifier is mounted above the table on a vertically movable arm which is on a longitudinally movable carriage. Electric control means are provided for angulating the X-ray source and image intensifier synchronously as the image intensifier system is shifted longitudinally or vertically such that the central ray from the X-ray source is kept intensifier

  8. Effect of Electric Voltage and Current of X-ray Chamber on the Element inthe Zirconium Alloy Analysis X-ray by X-ray Fluorescence

    International Nuclear Information System (INIS)

    Yusuf-Nampira; Narko-Wibowo, L; Rosika-Krisnawati; Nudia-Barenzani

    2000-01-01

    The using of x-ray fluorescence in the chemical analysis depend heavilyon the parameters of x-ray chamber, for examples : electric voltage andelectric current. That parameter give effect in the result of determine ofSn, Cr, Fe and Ni in the zirconium alloy. 20 kV electric voltages are used onthe Mo x-ray chamber shall product x-ray of zirconium in the sample materialcan give effect in the stability of the analysis result (deviation more than5%). The result of analysis of elements in the zirconium alloy shall givedeviation less than 5% when using of electric voltage of the x-ray chamberless than 19 kV. The sensitivity of analysis can be reached by step upelectric current of x-ray chamber. (author)

  9. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  10. Compound refractive X-ray lens

    Science.gov (United States)

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  11. INTEGRAL Upper Limits on Gamma-Ray Emission Associated with the Gravitational Wave Event GW150914

    DEFF Research Database (Denmark)

    Savchenko, V.; Ferrigno, C.; Mereghetti, S.

    2016-01-01

    Using observations of the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL), we place upper limits on the gamma-ray and hard X-ray prompt emission associated with the gravitational wave event GW150914, which was discovered by the LIGO/Virgo Collaboration. The omnidirectional view...... in the 75 keV-2 MeV energy range for typical spectral models. Our results constrain the ratio of the energy promptly released in gamma-rays in the direction of the observer to the gravitational wave energy Eγ/EGW ... of the gravitational wave source, based on the available predictions for prompt electromagnetic emission....

  12. X-ray diffraction device comprising cooling medium connections provided on the x-ray tube

    NARCIS (Netherlands)

    1996-01-01

    An X-ray diffraction device comprises a water-cooled X-ray tube which exhibits a line focus as well as, after rotation through 90 DEG , a point focus. Contrary to customary X-ray tubes, the cooling water is not supplied via the housing (12) in which the X-ray tube is mounted, but the cooling water

  13. X-ray hot plasma diagnostics

    International Nuclear Information System (INIS)

    Cojocaru, E.

    1984-11-01

    X-ray plasma emission study is powerful diagnostic tool of hot plasmas. In this review article the main techniques of X-ray plasma emission measurement are shortly presented: X-ray spectrometry using absorbent filters, crystal and grating spectrometers, imaging techniques using pinhole cameras, X-ray microscopes and Fresnel zone plate cameras, X-ray plasma emission calorimetry. Advances in these techniques with examples for different hot plasma devices are also presentes. (author)

  14. Color maps of X-ray globular clusters

    International Nuclear Information System (INIS)

    Bailyn, C.D.; Grindlay, J.E.; Cohn, H.; Lugger, P.M.

    1988-01-01

    The results of a search for optical counterparts to X-ray sources in six globular clusters, 47 Tuc, NGC 1851, NGC 6441, NGC 6624, NGC 6712, and M15, are reported. Maps of the U-B color of the central regions of the clusters were prepared. A candidate for the optical counterpart of the source in NGC 6712 was found, along with a blue region near the X-ray source in 47 Tuc. Upper limits on the colors and magnitudes of possible optical counterparts are reported for the other three clusters. The use of color maps to determine color gradients in globular clusters is explored. It is found that, while such gradients do exist and vary from cluster to cluster, they can be explained by crowding effects. Crude limits are placed on the excess populations of blue objects such as CVs, which have been postulated to be concentrated in the centers of dense clusters. 32 references

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  16. Soft x-ray streak cameras

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1988-01-01

    This paper is a discussion of the development and of the current state of the art in picosecond soft x-ray streak camera technology. Accomplishments from a number of institutions are discussed. X-ray streak cameras vary from standard visible streak camera designs in the use of an x-ray transmitting window and an x-ray sensitive photocathode. The spectral sensitivity range of these instruments includes portions of the near UV and extends from the subkilovolt x- ray region to several tens of kilovolts. Attendant challenges encountered in the design and use of x-ray streak cameras include the accommodation of high-voltage and vacuum requirements, as well as manipulation of a photocathode structure which is often fragile. The x-ray transmitting window is generally too fragile to withstand atmospheric pressure, necessitating active vacuum pumping and a vacuum line of sight to the x-ray signal source. Because of the difficulty of manipulating x-ray beams with conventional optics, as is done with visible light, the size of the photocathode sensing area, access to the front of the tube, the ability to insert the streak tube into a vacuum chamber and the capability to trigger the sweep with very short internal delay times are issues uniquely relevant to x-ray streak camera use. The physics of electron imaging may place more stringent limitations on the temporal and spatial resolution obtainable with x-ray photocathodes than with the visible counterpart. Other issues which are common to the entire streak camera community also concern the x-ray streak camera users and manufacturers

  17. New lidocaine lozenge as topical anesthesia compared to lidocaine viscous oral solution before upper gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Mogensen, Stine; Treldal, Charlotte; Feldager, Erik

    2012-01-01

    To evaluate the effect and acceptance of a new lidocaine lozenge compared with a lidocaine viscous oral solution as a pharyngeal anesthetic before upper gastrointestinal endoscopy (UGE), a diagnostic procedure commonly performed worldwide during which many patients experience severe discomfort...

  18. Portable X-ray fluorescence analyzer of high sensitivity using X-ray tube excitation

    International Nuclear Information System (INIS)

    Vatai, E.; Ando, L.

    1982-01-01

    A review of the three main methods of X-ray fluorescence analysis and their problems is given. The attainable accuracy and effectiveness of each method are discussed. The main properties of portable X-ray analyzers required by the industry are described. The results and experiences of R and D activities in ATOMKI (Debrecen, Hungary) for developing portable X-ray analyzers are presented. The only way for increasing the accuracy and decreasing the measuring time is the application of X-ray tube excitation instead of radioactive sources. The new ATOMKI equipment presently under construction and patenting uses X-ray tube excitation; it will increase the accuracy of concentration determination by one order of magnitude. (D.Gy.)

  19. X ray Production. Chapter 5

    Energy Technology Data Exchange (ETDEWEB)

    Nowotny, R. [Medical University of Vienna, Vienna (Austria)

    2014-09-15

    The differential absorption of X rays in tissues and organs, owing to their atomic composition, is the basis for the various imaging methods used in diagnostic radiology. The principles in the production of X rays have remained the same since their discovery. However, much refinement has gone into the design of X ray tubes to achieve the performance required for today’s radiological examinations. In this chapter, an outline of the principles of X ray production and a characterization of the radiation output of X ray tubes will be given. The basic processes producing X rays are dealt with in Section 1.4.

  20. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  1. X-ray astronomy 2000: Wide field X-ray monitoring with lobster-eye telescopes

    International Nuclear Information System (INIS)

    Inneman, A.; Hudec, R.; Pina, L.; Gorenstein, P.

    2001-01-01

    The recently available first prototypes of innovative very wide field X-ray telescopes of Lobster-Eye type confirm the feasibility to develop such flight instruments in a near future. These devices are expected to allow very wide field (more than 1000 square degrees) monitoring of the sky in X-rays (up to 10 keV and perhaps even more) with faint limits. We will discuss the recent status of the development of very wide field X-ray telescopes as well as related scientific questions including expected major contributions such as monitoring and study of X-ray afterglows of Gamma Ray Bursts

  2. A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements

    Energy Technology Data Exchange (ETDEWEB)

    Seidler, G. T., E-mail: seidler@uw.edu; Mortensen, D. R.; Remesnik, A. J.; Pacold, J. I.; Ball, N. A.; Barry, N.; Styczinski, M.; Hoidn, O. R. [Physics Department, University of Washington, Seattle, Washington 98195-1560 (United States)

    2014-11-15

    We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low power x-ray (bremsstrahlung) tube source, a spherically bent crystal analyzer, and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of ∼5 keV to ∼10 keV while also demonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy comparable to those achieved at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure, the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-power line-focused x-ray tube or rotating anode x-ray generator would result in monochromatized fluxes of order 10{sup 6}–10{sup 7} photons/s with no loss in energy resolution. This work establishes core technical capabilities for a rejuvenation of laboratory-based hard x-ray spectroscopies that could have special relevance for contemporary research on catalytic or electrical energy storage systems using transition-metal, lanthanide, or noble-metal active species.

  3. Illumination system for X-ray lithography

    International Nuclear Information System (INIS)

    Buckley, W.D.

    1989-01-01

    An X-ray lithography system is described, comprising: a point source of X-Ray radiation; a wafer plane disposed in spaced relation to the point source of X-Ray radiation; a mask disposed between the point source of X-Ray radiation and the wafer plane whereby X-Ray radiation from the point source of X-ray radiation passes through the mask to the water plane; and X-Ray absorbent means mounted between the point source of X-Ray radiation and the wafer plane, the X-Ray absorbent means being of quadratically absorption from maximum absorption at the center to minimum absorption at the edge so as to have a radial absorption gradient profile to compensate for radial flux variation of the X-Ray radiation

  4. An X-ray and optical study of the ultracompact X-ray binary A 1246-58

    NARCIS (Netherlands)

    in 't Zand, J.J.M.; Bassa, C.G.; Jonker, P.G.; Keek, L.; Verbunt, F.W.M.; Méndez, M.; Markwardt, C.B.

    2008-01-01

    Results are discussed of an X-ray and optical observation campaign of the low-mass X-ray binary A 1246-58 performed with instruments on Satellite per Astronomia X ("BeppoSAX"), the Rossi X-ray Timing Explorer (RXTE), the X-ray Multi-mirror Mission ("XMM-Newton"), the Swift mission, and the Very

  5. Ultra-luminous X-ray sources and intermediate-mass black holes

    International Nuclear Information System (INIS)

    Cseh, David

    2012-01-01

    More than ten years ago, the discovery of Ultra-luminous X-ray sources (ULXs) has opened up an entirely new field in astrophysics. Many ideas were developed to explain the nature of these sources, like their emission mechanism, mass, and origin, without any strong conclusions. Their discovery boosted the fields of X-ray binaries, accretion physics, stellar evolution, cosmology, black hole formation and growth, due to the concept of intermediate-mass black holes (IMBHs). Since their discovery is related to the domain of X-ray astrophysics, there have been very few studies made in other wavelengths. This thesis focuses on the multiwavelength nature of Ultra-luminous X-ray sources and intermediate-mass black holes from various aspects, which help to overcome some difficulties we face today. First, I investigated the accretion signatures of a putative intermediate-mass black hole in a particular globular cluster. To this purpose, I characterized the nature of the innermost X-ray sources in the cluster. Then I calculated an upper limit on the mass of the black hole by studying possible accretion efficiencies and rates based on the dedicated X-ray and radio observations. The accreting properties of the source was described with standard spherical accretion and in the context of inefficient accretion. Secondly, I attempted to dynamically measure the mass of the black hole in a particular ULX via optical spectroscopy. I discovered that a certain emission line has a broad component that markedly shifts in wavelength. I investigated the possibility whether this line originates in the accretion disk, and thus might trace the orbital motion of the binary system. I also characterized the parameters of the binary system, such as the mass function, possible orbital separation, the size of the line-emitting region, and an upper limit on the mass of the black hole. Then I studied the environment of a number of ULXs that are associated with large-scale optical and radio nebulae. I

  6. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  7. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey Rubin, a radiologist ... about chest x-rays, visit Radiology Info dot org. Thank you for your time! Spotlight Recently posted: ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... The x-ray tube is connected to a flexible arm that is extended over the patient while an x-ray film holder or image recording plate is placed beneath the patient. top of page How does the procedure work? X-rays are a form of radiation like ...

  10. Safety and efficacy of lansoprazole injection in upper gastrointestinal bleeding: a postmarketing surveillance conducted in Indonesia.

    Science.gov (United States)

    Syam, Ari F; Setiawati, Arini

    2013-04-01

    to assess the safety and effectiveness of lansoprazole injection (Prosogan®) in patients with upper gastrointestinal bleeding due to peptic ulcers or erosive gastritis. this study was a multicenter observational postmarketing study of lansoprazole (Prosogan®) injection. Patients with upper gastrointestinal bleeding due to peptic ulcers or erosive gastritis were given intravenous lansoprazole for a maximum of 7 days or until the bleeding stopped and the patients were able to take oral doses of lansoprazole. Primary outcome of the study was cessation of bleeding. Some laboratory parameters were also measured. among a total of 204 patients evaluable for safety, there was no adverse event reported during the study. A total of 200 patients were eligible for efficacy evaluation, 125 patients (62.5%) were males. Among these patients, upper GI bleeding stopped in 20 patients (10.0%) on day 1, in 71 patients (35.5%) on day 2, 75 patients (37.5%) on day 3, 24 patients (12.0%) on day 4, and 7 patients (3.5%) on day 5, making a cumulative of 197 patients (98.5%) on day 5. The hemostatic effect was rated as 'excellent' if the bleeding stopped within 3 days, and 'good' if the bleeding stopped within 5 days. Thus, the results were 'excellent' in 166 patients (83.0%) and 'good' in 31 patients (15.5%). These results were not different between males and females, between age below 60 years and 60 years and above, and between baseline Hb below 10 g/dL and 10 g/dL and above. the results of this observational postmarketing study in 200 patients with upper gastrointestinal bleeding due to peptic ulcers or erosive gastritis demonstrated that intravenous lansoprazole twice a day was well tolerated and highly effective.

  11. Management of Upper Gastrointestinal Bleeding in Children: Variceal and Nonvariceal.

    Science.gov (United States)

    Lirio, Richard A

    2016-01-01

    Upper gastrointestinal (UGI) bleeding is generally defined as bleeding proximal to the ligament of Treitz, which leads to hematemesis. There are several causes of UGI bleeding necessitating a detailed history to rule out comorbid conditions, medications, and possible exposures. In addition, the severity, timing, duration, and volume of the bleeding are important details to note for management purposes. Despite the source of the bleeding, acid suppression with a proton-pump inhibitor has been shown to be effective in minimizing rebleeding. Endoscopy remains the interventional modality of choice for both nonvariceal and variceal bleeds because it can be diagnostic and therapeutic. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. A search for X-rays from UV Ceti flare stars

    International Nuclear Information System (INIS)

    Crannell, C.J.; Spangler, S.R.

    1975-01-01

    A search of the MIT/OSO-7 data has been made for evidence of X-ray emission from flares of UV Ceti flare stars. Observations from McDonald Observatory have been used to identify the times of optical flares. The only instance of coincident coverage occurred on 1974 January 21 UT at 03:43:26 GMT for a Δm = 0.86 flare of YZ CMi. No radio coverage of this particular event was obtained. Upper limits of 0.8, 1.0, and 0.7 photons/cm 2 s on the observed X-ray flux have been set for the energy ranges >= 15, >= 3, and 1-10 keV, respectively. (orig.) [de

  13. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  14. X-ray filtration apparatus

    International Nuclear Information System (INIS)

    Thompson, G.

    1992-01-01

    This invention relates to an X-ray shielding support device. In spite of considerable development in X-ray taking techniques, a need still exists for effective shielding, inter alia, to compensate for variations in the thickness, density and the absorption properties of the object being studied. By appropriate shielding, the X-ray image produced is of sufficient detail, contrast and intensity over its entire area to constitute a useful diagnostic aid. It is also desirable to subject the patient to the smallest possible X-ray dosage. 4 figs

  15. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  16. Systematic Review and Net-Work Meta-Analysis of Upper Gastrointestinal Hemorrhage Interventions

    Directory of Open Access Journals (Sweden)

    Mengyuan Jiang

    2016-11-01

    Full Text Available Background/Aims: Upper gastrointestinal hemorrhage (UGH is a serious medical condition which affects a large number of individuals. Endoscopic therapy accompanied by medication is a standard approach that is used to improve the prognosis of UGH patients and a few medications have been developed including proton pump inhibitors (PPIs, histamine H2 receptor antagonist (H2RA, somatostatin analogues and tranexamic acid. This study is set to compare the efficacy and safety of various medical interventions that are used to manage upper gastrointestinal bleeding. Methods: We searched PubMed, Cochrane Library, and Embase for relevant articles. Eligible studies were determined by using both the inclusion and exclusion criteria. Both traditional pair-wise meta-analysis and net-work analysis were carried out to evaluate the corresponding interventions. Results and Conclusion: PPI is an effective medication for UGH patients and intravenous PPI exhibits equivalent effectiveness and safety in comparison to oral PPI. H2RA is not recommended for UGH patients as patients treated with H2RA are associated with an increased risk of adverse events including rebleeding, need for surgery and all-cause mortality. Moreover, patients treated with H2RA exhibit an increased length of average hospital stay and blood transfusion amount compared to those treated with PPI. Tranexamic acid is also considered as another promising medication for UGH.

  17. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  18. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  19. Comparative study of radiation dose between digital panoramic X-ray unit and general panoramic X-ray unit

    International Nuclear Information System (INIS)

    Li Qingshan; Duan Tao; Wang Xiaoyun; Zhao Li; Dong Jian; Wei Lei

    2010-01-01

    Objective: To compare the actual dose of patients who receive the same medical practice by either digital panoramic X-ray unit and general panoramic X-ray unit and give evidence for better selection of oral X-ray examination method. Methods: Round sheet lithium fluoride (LiF) thermoluminescent dosimeters (TLD) were used. The experiment was divided into natural background contrast group, general panoramic X-ray children group, general panoramic X-ray adults group, digital panoramic X-ray children group and digital panoramic X-ray adults group. The dosimeter of natural background radiation was placed at the office of the doctor, the dosimeters of general panoramic X-ray children group and general panoramic X-ray adults group were irradiated by different conditions according to the clinical application of panoramic X-ray to children and adults, the dosimeters of digital panoramic X-ray children group and digital panoramic X-ray adults group were irradiated by different conditions according to the clinical application of digital panoramic X-ray to children and adults. The thermoluminescent dosimeter was used to count and calculate the exposure doses in various groups. Results: The dose of children exposed in general panoramic X-ray unit was 1.28 times of that in digital panoramic X-ray unit, there was significant difference (t=6.904, P<0.01). The dose of adults exposed in general panoramic X-ray unit was 1.55 times of that in the digital panoramic X-ray unit, there also was significant difference (t=-11.514. P< 0.01). Conclusion: The digital panoramic X-ray unit can reduce the dose of patients, so the digital panoramic X-ray unit should be used as far as possible. (authors)

  20. Nanoparticle-Assisted Scanning Focusing X-Ray Therapy with Needle Beam X Rays.

    Science.gov (United States)

    Davidson, R Andrew; Guo, Ting

    2016-01-01

    In this work, we show a new therapeutic approach using 40-120 keV X rays to deliver a radiation dose at the isocenter located many centimeters below the skin surface several hundred times greater than at the skin and how this dose enhancement can be augmented with nanomaterials to create several thousand-fold total dose enhancement effect. This novel approach employs a needle X-ray beam directed at the isocenter centimeters deep in the body while continuously scanning the beam to cover a large solid angle without overlapping at the skin. A Monte Carlo method was developed to simulate an X-ray dose delivered to the isocenter filled with X-ray absorbing and catalytic nanoparticles in a water phantom. An experimental apparatus consisting of a moving plastic phantom irradiated with a stationary 1 mm needle X-ray beam was built to test the theoretical predictions. X-ray films were used to characterize the dose profiles of the scanning X-ray apparatus. Through this work, it was determined that the X-ray dose delivered to the isocenter in a treatment voxel (t-voxel) underneath a 5 cm deep high-density polyethylene (HDPE) phantom was 295 ± 48 times greater than the surface dose. This measured value was in good agreement with the theoretical predicted value of 339-fold. Adding X-ray-absorbing nanoparticles, catalytic nanoparticles or both into the t-voxel can further augment the dose enhancement. For example, we predicted that adding 1 weight percentage (wp) of gold into water could increase the effective dose delivered to the target by onefold. Dose enhancement using 1 mm X-ray beam could reach about 1,600-fold in the t-voxel when 7.5 wp of 88 nm diameter silica-covered gold nanoparticles were added, which we showed in a previously published study can create a dose enhancement of 5.5 ± 0.46-fold without scanning focusing enhancement. Based on the experimental data from that study, mixing 0.02 wp 2.5 nm diameter small tetrakis hydroxymethyl phosphonium chloride (THPC

  1. X-ray astronomy

    International Nuclear Information System (INIS)

    Narayanan, M.S.

    1976-01-01

    The deployment of detectors outside the deleterious effects of the atmosphere by sending them in space vehicles, has been explained. This has thrown open the entire spectrum of the electromagnetic and particle radiation to direct observations, thus enlarging the vistas of the field of astronomy and astrophysics. The discovery of strong emitters of X-rays such as SCO X-1, NorX-2, transient sources such as Cen X-2, Cen X-4, Cen X-1, Supernova remnants Tan X-1, etc., are reported. The background of the X-ray spectrum as measured during two rocket flights over Thumba, India is presented. (K.B.)

  2. Application of X-ray CCD camera in X-ray spot diagnosis of rod-pinch diode

    International Nuclear Information System (INIS)

    Song Yan; Zhou Ming; Song Guzhou; Ma Jiming; Duan Baojun; Han Changcai; Yao Zhiming

    2015-01-01

    The pinhole imaging technique is widely used in the measurement of X-ray spot of rod-pinch diode. The X-ray CCD camera, which was composed of film, fiber optic taper and CCD camera, was employed to replace the imaging system based on scintillator, lens and CCD camera in the diagnosis of X-ray spot. The resolution of the X-ray CCD camera was studied. The resolution is restricted by the film and is 5 lp/mm in the test with Pb resolution chart. The frequency is 1.5 lp/mm when the MTF is 0.5 in the test with edge image. The resolution tests indicate that the X-ray CCD camera can meet the requirement of the diagnosis of X-ray spot whose scale is about 1.5 mm when the pinhole imaging magnification is 0.5. At last, the image of X-ray spot was gained and the restoration was implemented in the diagnosis of X-ray spot of rod-pinch diode. (authors)

  3. Scintillating ribbon x-ray detector

    International Nuclear Information System (INIS)

    Kinchen, B.E.; Rogers, A.

    1995-01-01

    A patent in the early 1970's by Aerojet Corporation in Sacramento, CA put forth the idea of using an array of scintillating fibers for x-ray detection and imaging. In about 1975, Pratt and Whitney Aircraft in East Hartford, CT designed and manufactured an imaging system based on the patent. The device was 1.75 in thick in the direction of the x-ray beam and about 4 in. by 4 in. square. The device was used with a 8 MeV x-ray source to image and measure internal clearances within operating aircraft, gas turbines engines. There are significant advantages of fiber optic detectors in x-ray detection. However, the advantages are often outweighed by the disadvantages. Two of the advantages of scintillating fiber optic x-ray detectors are: (1) high limiting spatial frequency -- between 20 and 25 lp/mm; and (2) excellent x-ray stopping power -- they can be made thick and retain spatial resolution. In traditional fiber optic detectors the x-rays are oriented parallel to the long axis of the fiber. For the scintillating ribbon x-ray sensor, the x-rays are oriented normal to the fiber long axis. This ribbon sensor technique has a number of advantages over the two current radiographic techniques digital x-radiography and x-ray film: The main advantage the ribbon has is size and shape. It can be as thin as 0.05 in., virtually any width or length, and flexible. Once positioned in a given location, 20 to 100 square inches of the object being inspected can be imaged with a single x-ray beam sweep. It is clear that conventional digital cameras do not lend themselves to placement between walls of aircraft structures or similar items requiring x-ray inspections. A prototype scintillating ribbon x-ray sensor has been fabricated and tested by Synergistic Detector Designs. Images were acquired on corrosion test panels of aluminum fabricated by Iowa State University

  4. Center for X-Ray Optics, 1992

    International Nuclear Information System (INIS)

    1993-08-01

    This report discusses the following topics: Center for X-Ray Optics; Soft X-Ray Imaging wit Zone Plate Lenses; Biological X-Ray microscopy; Extreme Ultraviolet Lithography for Nanoelectronic Pattern Transfer; Multilayer Reflective Optics; EUV/Soft X-ray Reflectometer; Photoemission Microscopy with Reflective Optics; Spectroscopy with Soft X-Rays; Hard X-Ray Microprobe; Coronary Angiography; and Atomic Scattering Factors

  5. The complete Einstein Observatory X-ray survey of the Orion Nebula region.

    Science.gov (United States)

    Gagne, Marc; Caillault, Jean-Pierre

    1994-01-01

    We have analyzed archival Einstein Observatory images of a roughly 4.5 square degree region centered on the Orion Nebula. In all, 245 distinct X-ray sources have been detected in six High Resolution Imager (HRI) and 17 Imaging Proportional Counter (IPC) observations. An optical database of over 2700 stars has been assembled to search for candidate counterparts to the X-ray sources. Roughly half the X-ray sources are identified with a single Orion Nebula cluster member. The 10 main-sequence O6-B5 cluster stars detected in Orion have X-ray activity levels comparable to field O and B stars. X-ray emission has also been detected in the direction of four main-sequence late-B and early-A type stars. Since the mechanisms producing X-rays in late-type coronae and early-type winds cannot operate in the late-B and early-A type atmospheres, we argue that the observed X-rays, with L(sub X) approximately = 3 x 10(exp 30) ergs/s, are probably produced in the coronae of unseen late-type binary companions. Over 100 X-ray sources have been associated with late-type pre-main sequence stars. The upper envelope of X-ray activity rises sharply from mid-F to late-G, with L(sub x)/L(sub bol) in the range 10(exp -4) to 2 x 10(exp -3) for stars later than approximately G7. We have looked for variability of the late-type cluster members on timescales of a day to a year and find that 1/4 of the stars show significantly variable X-ray emission. A handful of the late-type stars have published rotational periods and spectroscopic rotational velocities; however, we see no correlation between X-ray activity and rotation. Thus, for this sample of pre-main-sequence stars, the large dispersion in X-ray activity does not appear to be caused by the dispersion in rotation, in contrast with results obtained for low-mass main-sequence stars in the Pleiades and pre-main-sequence stars in Taurus-Auriga.

  6. JEM-X: The X-ray monitor on INTEGRAL

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; Lund, Niels; Westergaard, Niels Jørgen Stenfeldt

    2004-01-01

    The INTEGRAL X-ray monitor, JEM-X, (together with the two gamma ray instruments, SPI and IBIS) provides simultaneous imaging with arcminute angular resolution in the 3-35 keV band. The good angular resolution and low energy response of JEM-X plays an important role in the detection and identifica......The INTEGRAL X-ray monitor, JEM-X, (together with the two gamma ray instruments, SPI and IBIS) provides simultaneous imaging with arcminute angular resolution in the 3-35 keV band. The good angular resolution and low energy response of JEM-X plays an important role in the detection...

  7. Searching for Axions from Celestial Objects with the X-Ray Telescope at CAST

    CERN Document Server

    Guthörl, T

    2009-01-01

    The CAST (CERN Solar Axion Telescope) experiment is designed to detect axions from the sun by making use of the inverse Primakoff effekt i.e. reconversion of axions into X-ray photons under the influence of a strong magnetic field. In order to track the sun the magnet used is mounted to a moveable device. This movability can also be used to track celestial objects of interest such as the galactic centre or Scorpio X-1, which is the brightest X-ray source besides the sun. The data gained with the CCD detector during trackings of these objects are analysed in this work. Since no signal above background can be observed an upper limit on the free parameter flux times axion-photon coupling constant^2 is determined. This upper limit in turn can be used to calculate a maximum energy loss due to axion emission for both the galactic centre and Sco X-1. The results presented in this work imply that e.g. the galactic centre can emit axions with up to 10^42 W without being detected by CAST.

  8. X ray spectra of X Per. [oso-8 observations

    Science.gov (United States)

    Becker, R. H.; Boldt, E. A.; Holt, S. S.; Pravdo, S. H.; Robinson-Saba, J.; Serlemitsos, P. J.; Swank, J. H.

    1978-01-01

    The cosmic X-ray spectroscopy experiment on OSO-8 observed X Per for twenty days during two observations in Feb. 1976 and Feb. 1977. The spectrum of X Per varies in phase with its 13.9 min period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, X Per's spectra do not exhibit iron line emission or strong absorption features. The data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low density region far from the optically identified Be star.

  9. JEM-X: The X-ray monitor on INTEGRAL

    DEFF Research Database (Denmark)

    Lund, Niels; Budtz-Jørgensen, Carl; Westergaard, Niels Jørgen Stenfeldt

    1999-01-01

    and identification of gamma ray sources as well as in the analysis and scientific interpretation of the combined X-ray and gamma ray data. JEM-X is a coded aperture X-ray telescope consisting of two identical detectors. Each detector has a sensitive area of 500 cm(2), and views the sky (6.6 deg FOV, FWHM) through...

  10. Upper Gastrointestinal (GI) Series

    Science.gov (United States)

    ... standard barium upper GI series, which uses only barium a double-contrast upper GI series, which uses both air and ... evenly coat your upper GI tract with the barium. If you are having a double-contrast study, you will swallow gas-forming crystals that ...

  11. Accelerator-driven X-ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-09

    After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

  12. Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography

    Science.gov (United States)

    Zappala, Susan; Helliwell, Jonathan R.; Tracy, Saoirse R.; Mairhofer, Stefan; Sturrock, Craig J.; Pridmore, Tony; Bennett, Malcolm; Mooney, Sacha J.

    2013-01-01

    X-ray Computed Tomography (CT) is a non-destructive imaging technique originally designed for diagnostic medicine, which was adopted for rhizosphere and soil science applications in the early 1980s. X-ray CT enables researchers to simultaneously visualise and quantify the heterogeneous soil matrix of mineral grains, organic matter, air-filled pores and water-filled pores. Additionally, X-ray CT allows visualisation of plant roots in situ without the need for traditional invasive methods such as root washing. However, one routinely unreported aspect of X-ray CT is the potential effect of X-ray dose on the soil-borne microorganisms and plants in rhizosphere investigations. Here we aimed to i) highlight the need for more consistent reporting of X-ray CT parameters for dose to sample, ii) to provide an overview of previously reported impacts of X-rays on soil microorganisms and plant roots and iii) present new data investigating the response of plant roots and microbial communities to X-ray exposure. Fewer than 5% of the 126 publications included in the literature review contained sufficient information to calculate dose and only 2.4% of the publications explicitly state an estimate of dose received by each sample. We conducted a study involving rice roots growing in soil, observing no significant difference between the numbers of root tips, root volume and total root length in scanned versus unscanned samples. In parallel, a soil microbe experiment scanning samples over a total of 24 weeks observed no significant difference between the scanned and unscanned microbial biomass values. We conclude from the literature review and our own experiments that X-ray CT does not impact plant growth or soil microbial populations when employing a low level of dose (<30 Gy). However, the call for higher throughput X-ray CT means that doses that biological samples receive are likely to increase and thus should be closely monitored. PMID:23840640

  13. Synchrotron x-ray fluorescence and extended x-ray absorption fine structure analysis

    International Nuclear Information System (INIS)

    Chen, J.R.; Gordon, B.M.; Hanson, A.L.; Jones, K.W.; Kraner, H.W.; Chao, E.C.T.; Minkin, J.A.

    1984-01-01

    The advent of dedicated synchrotron radiation sources has led to a significant increase in activity in many areas of science dealing with the interaction of x-rays with matter. Synchrotron radiation provides intense, linearly polarized, naturally collimated, continuously tunable photon beams, which are used to determine not only the elemental composition of a complex, polyatomic, dilute material but also the chemical form of the elements with improved accuracy. Examples of the application of synchrotron radiation include experiments in synchrotron x-ray fluorescence (SXRF) analysis and extended x-ray absorption fine structure (EXAFS) analysis. New synchrotron radiation x-ray microprobes for elemental analysis in the parts per billion range are under construction at several laboratories. 76 references, 24 figures

  14. X-ray exposures to dental patients

    International Nuclear Information System (INIS)

    McKlveen, J.W.

    1980-01-01

    An elastic mask worn by patients and a skeleton encased in plastic were instrumented with LiF thermoluminescent dosimeters to determine radiation exposures delivered from full-face diagnostic dental X-rays. Measurements were made using various panoramic radiographical and periapical machines. Locations of interest included skin surface, eyes, upper and lower teeth and thyroid. Exposures in the 100 mR range were common and a maximum of over 6000 mR was measured in the teeth region during a full-face examination with a periapical unit. In general, exposures received from periapical equipment were several times those obtained from panoramic devices. (author)

  15. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... Emitting Products and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin it ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most x- ...

  16. Stellar X-ray sources

    International Nuclear Information System (INIS)

    Katz, J.I.; Washington Univ., St. Louis, MO

    1988-01-01

    I Review some of the salient accomplishments of X-rap studies of compact objects. Progress in this field has closely followed the improvement of observational methods, particularly in angular resolution and duration of exposure. Luminous compact X-ray sources are accreting neutron stars or black holes. Accreting neutron stars may have characteristic temporal signatures, but the only way to establish that an X-ray source is a black hole is to measure its mass. A rough phenomenological theory is succesful, but the transport of angular momentum in accretion flows is not onderstood. A number of interesting complications have been observed, including precessing accretion discs, X-ray bursts, and the acceleration of jets in SS433. Many puzzles remain unsolved, including the excitation of disc precession, the nature of the enigmatic A- and gamma-ray source Cyg X-3, the mechanism by which slowly spinning accreting neutron stars lose angular momentum, and the superabundance of X-ray sources in globular clusters. 41 refs.; 5 figs

  17. Diagnostic accuracy of CT angiography in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chua, A. E.; Ridley, L. J.

    2008-01-01

    Full text: The aim of the study was to carry out a systematic review determining the accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding. A search of published work in Medline and manual searching of reference lists of articles was conducted. Studies were included if they compared CT angiography to a reference standard of upper gastrointestinal endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute gastrointestinal bleeding. Eight published studies evaluating 129 patients were included. Data were used to form 2 x2 tables. Computed tomography angiography showed pooled sensitivity of 86% (95% confidence interval 78-92%) and specificity of 95% (95% confidence interval 76-100%), without showing significant heterogeneity (x 2 = 3.5, P=0.6) and (x 2 - 5.4, P = 0.6), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.93. Computed tomography angiography is accurate in the diagnosis of acute gastrointestinal bleeding and can show the precise location and aetiology of bleeding, thereby directing further management. Strong recommendations for use of CT cannot be made from this review because of the methodological limitations and further large prospective studies are needed to define the role of CT in acute gastrointestinal bleeding.

  18. Prediction scores or gastroenterologists' Gut Feeling for triaging patients that present with acute upper gastrointestinal bleeding

    NARCIS (Netherlands)

    Groot, N.; Oijen, M.G. van; Kessels, K.; Hemmink, M.; Weusten, B.; Timmer, R.; Hazen, W.; Lelyveld, N. van; Vermeijden, J.R.; Curvers, W.; Baak, L.; Verburg, R.; Bosman, J.; Wijkerslooth, L. de; Rooij, J van; Venneman, N.; Pennings, M.C.P.; Hee, K. van; Scheffer, R.; Eijk, R. van; Meiland, R.; Siersema, P.D.; Bredenoord, A.

    2014-01-01

    INTRODUCTION: Several prediction scores for triaging patients with upper gastrointestinal (GI) bleeding have been developed, yet these scores have never been compared to the current gold standard, which is the clinical evaluation by a gastroenterologist. The aim of this study was to assess the added

  19. Prediction scores or gastroenterologists' Gut Feeling for triaging patients that present with acute upper gastrointestinal bleeding

    NARCIS (Netherlands)

    de Groot, N. L.; van Oijen, M. G. H.; Kessels, K.; Hemmink, M.; Weusten, B. L. A. M.; Timmer, R.; Hazen, W. L.; van Lelyveld, N.; Vermeijden, J. R.; Curvers, W. L.; Baak, L. C.; Verburg, R.; Bosman, J. H.; de Wijkerslooth, L. R. H.; de Rooij, J.; Venneman, N. G.; Pennings, M.; van Hee, K.; Scheffer, R. C. H.; van Eijk, R. L.; Meiland, R.; Siersema, P. D.; Bredenoord, A. J.

    2014-01-01

    Introduction: Several prediction scores for triaging patients with upper gastrointestinal (GI) bleeding have been developed, yet these scores have never been compared to the current gold standard, which is the clinical evaluation by a gastroenterologist. The aim of this study was to assess the added

  20. Toward Adaptive X-Ray Telescopes

    Science.gov (United States)

    O'Dell, Stephen L.; Atkins, Carolyn; Button, Tim W.; Cotroneo, Vincenzo; Davis, William N.; Doel, Peer; Feldman, Charlotte H.; Freeman, Mark D.; Gubarev, Mikhail V.; Kolodziejczak, Jeffrey J.; hide

    2011-01-01

    Future x-ray observatories will require high-resolution (less than 1 inch) optics with very-large-aperture (greater than 25 square meter) areas. Even with the next generation of heavy-lift launch vehicles, launch-mass constraints and aperture-area requirements will limit the surface areal density of the grazing-incidence mirrors to about 1 kilogram per square meter or less. Achieving sub-arcsecond x-ray imaging with such lightweight mirrors will require excellent mirror surfaces, precise and stable alignment, and exceptional stiffness or deformation compensation. Attaining and maintaining alignment and figure control will likely involve adaptive (in-space adjustable) x-ray optics. In contrast with infrared and visible astronomy, adaptive optics for x-ray astronomy is in its infancy. In the middle of the past decade, two efforts began to advance technologies for adaptive x-ray telescopes: The Generation-X (Gen-X) concept studies in the United States, and the Smart X-ray Optics (SXO) Basic Technology project in the United Kingdom. This paper discusses relevant technological issues and summarizes progress toward adaptive x-ray telescopes.

  1. Charge collection and absorption-limited x-ray sensitivity of pixellated x-ray detectors

    International Nuclear Information System (INIS)

    Kabir, M. Zahangir; Kasap, S.O.

    2004-01-01

    The charge collection and absorption-limited x-ray sensitivity of a direct conversion pixellated x-ray detector operating in the presence of deep trapping of charge carriers is calculated using the Shockley-Ramo theorem and the weighting potential of the individual pixel. The sensitivity of a pixellated x-ray detector is analyzed in terms of normalized parameters; (a) the normalized x-ray absorption depth (absorption depth/photoconductor thickness), (b) normalized pixel width (pixel size/thickness), and (c) normalized carrier schubwegs (schubweg/thickness). The charge collection and absorption-limited sensitivity of pixellated x-ray detectors mainly depends on the transport properties (mobility and lifetime) of the charges that move towards the pixel electrodes and the extent of dependence increases with decreasing normalized pixel width. The x-ray sensitivity of smaller pixels may be higher or lower than that of larger pixels depending on the rate of electron and hole trapping and the bias polarity. The sensitivity of pixellated detectors can be improved by ensuring that the carrier with the higher mobility-lifetime product is drifted towards the pixel electrodes

  2. Search for very high-energy gamma-ray emission from the microquasar Cygnus X-1 with the MAGIC telescopes

    Science.gov (United States)

    Ahnen, M. L.; Ansoldi, S.; Antonelli, L. A.; Arcaro, C.; Babić, A.; Banerjee, B.; Bangale, P.; Barres de Almeida, U.; Barrio, J. A.; Becerra González, J.; Bednarek, W.; Bernardini, E.; Berti, A.; Bhattacharyya, W.; Biasuzzi, B.; Biland, A.; Blanch, O.; Bonnefoy, S.; Bonnoli, G.; Carosi, R.; Carosi, A.; Chatterjee, A.; Colin, P.; Colombo, E.; Contreras, J. L.; Cortina, J.; Covino, S.; Cumani, P.; da Vela, P.; Dazzi, F.; de Angelis, A.; de Lotto, B.; de Oña Wilhelmi, E.; di Pierro, F.; Doert, M.; Domínguez, A.; Dominis Prester, D.; Dorner, D.; Doro, M.; Einecke, S.; Eisenacher Glawion, D.; Elsaesser, D.; Engelkemeier, M.; Fallah Ramazani, V.; Fernández-Barral, A.; Fidalgo, D.; Fonseca, M. V.; Font, L.; Fruck, C.; Galindo, D.; García López, R. J.; Garczarczyk, M.; Gaug, M.; Giammaria, P.; Godinović, N.; Gora, D.; Guberman, D.; Hadasch, D.; Hahn, A.; Hassan, T.; Hayashida, M.; Herrera, J.; Hose, J.; Hrupec, D.; Ishio, K.; Konno, Y.; Kubo, H.; Kushida, J.; Kuveždić, D.; Lelas, D.; Lindfors, E.; Lombardi, S.; Longo, F.; López, M.; Maggio, C.; Majumdar, P.; Makariev, M.; Maneva, G.; Manganaro, M.; Mannheim, K.; Maraschi, L.; Mariotti, M.; Martínez, M.; Mazin, D.; Menzel, U.; Minev, M.; Mirzoyan, R.; Moralejo, A.; Moreno, V.; Moretti, E.; Neustroev, V.; Niedzwiecki, A.; Nievas Rosillo, M.; Nilsson, K.; Ninci, D.; Nishijima, K.; Noda, K.; Nogués, L.; Paiano, S.; Palacio, J.; Paneque, D.; Paoletti, R.; Paredes, J. M.; Paredes-Fortuny, X.; Pedaletti, G.; Peresano, M.; Perri, L.; Persic, M.; Prada Moroni, P. G.; Prandini, E.; Puljak, I.; Garcia, J. R.; Reichardt, I.; Rhode, W.; Ribó, M.; Rico, J.; Righi, C.; Saito, T.; Satalecka, K.; Schroeder, S.; Schweizer, T.; Sitarek, J.; Šnidarić, I.; Sobczynska, D.; Stamerra, A.; Strzys, M.; Surić, T.; Takalo, L.; Tavecchio, F.; Temnikov, P.; Terzić, T.; Tescaro, D.; Teshima, M.; Torres, D. F.; Torres-Albà, N.; Treves, A.; Vanzo, G.; Vazquez Acosta, M.; Vovk, I.; Ward, J. E.; Will, M.; Zarić, D.; MAGIC Collaboration; Bosch-Ramon, V.; Pooley, G. G.; Trushkin, S. A.; Zanin, R.

    2017-12-01

    The microquasar Cygnus X-1 displays the two typical soft and hard X-ray states of a black hole transient. During the latter, Cygnus X-1 shows a one-sided relativistic radio-jet. Recent detection of the system in the high energy (HE; E ≳ 60 MeV) gamma-ray range with Fermi-LAT associates this emission with the outflow. Former MAGIC observations revealed a hint of flaring activity in the very high-energy (VHE; E ≳ 100 GeV) regime during this X-ray state. We analyse ∼97 h of Cygnus X-1 data taken with the MAGIC telescopes between July 2007 and October 2014. To shed light on the correlation between hard X-ray and VHE gamma rays as previously suggested, we study each main X-ray state separately. We perform an orbital phase-folded analysis to look for variability in the VHE band. Additionally, to place this variability behaviour in a multiwavelength context, we compare our results with Fermi-LAT, AGILE, Swift-BAT, MAXI, RXTE-ASM, AMI and RATAN-600 data. We do not detect Cygnus X-1 in the VHE regime. We establish upper limits for each X-ray state, assuming a power-law distribution with photon index Γ = 3.2. For steady emission in the hard and soft X-ray states, we set integral upper limits at 95 per cent confidence level for energies above 200 GeV at 2.6 × 10-12 photons cm-2 s-1 and 1.0 × 10-11 photons cm-2 s-1, respectively. We rule out steady VHE gamma-ray emission above this energy range, at the level of the MAGIC sensitivity, originating in the interaction between the relativistic jet and the surrounding medium, while the emission above this flux level produced inside the binary still remains a valid possibility.

  3. Upper gastrointestinal endoscopy at the korle bu teaching hospital, accra, ghana.

    Science.gov (United States)

    Aduful, Hk; Naaeder, Sb; Darko, R; Baako, Bn; Clegg-Lamptey, Jna; Nkrumah, Kn; Adu-Aryee, Na; Kyere, M

    2007-03-01

    To study the indications for endoscopy, the endoscopic diagnosis and other lessons learnt. A retrospective and prospective audit of all upper gastrointestinal endoscopies performed in the Endoscopy Unit of the Korle-Bu Teaching Hospital from January 1995 to December 2002 was performed. A total of 6977 patients, 3777 males and 3200 females with age range 1 year 8 months to 93 years were endoscoped. The mean age of males was 43.5 +/- 0.5 and females 43.7 +/- 0.6 years. Epigastric pain (42.5%), dyspepsia (32.8%) and haematemesis and melaena (14.2%) were the commonest reasons for endoscopy. Chronic duodenal ulcer (19.6%), acute gastritis (12.7%), duodenitis (10.2%), oesophagitis (7.5%) were the commonest diagnoses. Normal endoscopy was reported in 41.1% patients, and was higher in the younger age group compared to the older (R = 0.973, P<0.001). Nine hundred and ninety (14.2%) patients were endoscoped for haematemesis and melaena of which chronic duodenal ulcer (32.1%), gastritis/gastric erosions (12.8%), oesophageal varices (9.8%), carcinoma of the stomach (6.4%), and duodenitis (4.2%), were the commonest causes. No lesion was found in 20.6% of these patients. Urease test was positive in 75% of all biopsy specimen and 85% in chronic duodenal ulcer, gastritis and duodenitis. The normal endoscopy rate is high and needs to be reduced in order to help prolong the lives of the endoscopes. Chronic duodenal ulcer is usually associated with H. pylori infection and is the commonest cause of upper gastrointestinal bleeding.

  4. X-ray interferometers

    International Nuclear Information System (INIS)

    Franks, A.

    1980-01-01

    An improved type of amplitude-division x-ray interferometer is described. The wavelength at which the interferometer can operate is variable, allowing the instrument to be used to measure x-ray wavelength, and the angle of inclination is variable for sample investigation. (U.K.)

  5. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  6. Predictive values of upper gastrointestinal cancer alarm symptoms in the general population - a nationwide cohort study

    DEFF Research Database (Denmark)

    Rasmussen, Sanne; Haastrup, Peter Fentz; Balasubramaniam, Kirubakaran

    2018-01-01

    BACKGROUND: Survival rates for upper gastrointestinal (GI) cancer are poor since many are diagnosed at advanced stages. Fast track endoscopy has been introduced to prompt diagnosis for patients with alarm symptoms that could be indicative of upper GI cancer. However, these symptoms may represent...... to complete a survey comprising of questions on several symptom experiences, including alarm symptoms for upper GI cancer within the past four weeks. The participants were asked about specific symptoms (repeated vomiting, difficulty swallowing, signs of upper GI bleeding or persistent and recent......-onset abdominal pain) and non-specific symptoms (nausea, weight loss, loss of appetite, feeling unwell and tiredness). We obtained information on upper GI cancer diagnosed in a 12-month period after completing the questionnaire from the Danish Cancer Registry. We calculated positive predictive values and positive...

  7. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  8. Impact of endoscopic ultrasonography (EUS) on surgical decision-making in upper gastrointestinal tract cancer

    DEFF Research Database (Denmark)

    Mortensen, Michael Bau; Edwin, B; Hünerbein, M

    2007-01-01

    BACKGROUND: Endoscopic ultrasonography (EUS) is an integrated part of the pretherapeutic evaluation program for patients with upper gastrointestinal (GI) tract cancer. Whether the clinical impact of EUS differs between surgeons from different countries is unknown. The same applies to the potential...... clinical influence of EUS misinterpretations. The aim of this study was to evaluate the interobserver agreement on predefined treatment strategies between surgeons from four different countries, with and without EUS, and to evaluate the clinical consequences of EUS misinterpretations. METHODS: One hundred...... patients with upper GI tract cancer were randomly selected from all upper GI tract cancer patients treated at Odense University Hospital between 1997 and 2000. Based on patient records and EUS database results, a case story was created with and without the EUS result for each patient. Four surgeons were...

  9. Clinical Diagnosis of Achalasia: How Reliable is the Barium X-Ray?

    Directory of Open Access Journals (Sweden)

    I El-Takli

    2006-01-01

    Full Text Available Manometry is considered to be the gold standard for the diagnosis of achalasia. However, many physicians believe that contrast radiography, classically showing esophageal dilation with bird-beak narrowing of the gastroesophageal junction, is also accurate in either diagnosing or excluding the disorder. The aim of the current study was to determine the accuracy of barium x-ray in the diagnosis of achalasia. The radiological diagnosis of all patients manometrically diagnosed with achalasia (using conventional criteria between January 1994 and June 1998 were reviewed. A total of 51 cases of achalasia were identified. Thirteen patients were excluded because they either did not have contrast radiography before a manometric diagnosis or had their x-rays performed more than six months previously. Of the remaining 38 patients, achalasia was stated as a diagnostic possibility in the radiologists report in only 22 (58% of those patients. Achalasia was not considered in the remaining 16 patients: two were reported as normal, four as having stenosis/narrowing in distal esophagus, two as having presbyesophagus, one as having mild gastroesophageal reflux and seven as having nonspecific dysmotility. To determine the reason for the diagnostic failure of the barium x-ray, an expert gastrointestinal radiologist reviewed 12 of the nondiagnostic x-rays in a blinded fashion, interspersed with 10 randomly selected esophageal-contrast radiographs from control subjects to avoid bias. Of these initially nondiagnostic x-rays in achalasia patients, typical radiological features of achalasia were deemed to be present in 50%. The present study indicates that contrast radiography lacks sensitivity in the diagnosis of achalasia. This is not only due to radiologist oversight but also because of the absence of the characteristic radiological features in many cases. This reinforces the important role of esophageal manometry in patients with persistent nonstructural dysphagia.

  10. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  11. Upsurge of X-ray astronomy 230-

    International Nuclear Information System (INIS)

    Hudec, D.R.

    1978-01-01

    Instruments are described used for X-ray astronomy, namely X-ray detectors and X-ray telescopes. Unlike telescopes, the detectors do not comprise X-ray optics. A survey is given of the results obtained in solar and stellar X-ray astronomy and hypotheses are submitted on the origin of X radiation in the interstellar space. (J.B.)

  12. Review of X-ray Tomography and X-ray Fluorescence Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Shear, Trevor A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-16

    This literature review will focus on both laboratory and synchrotron based X-ray tomography of materials and highlight the inner workings of these instruments. X-ray fluorescence spectroscopy will also be reviewed and applications of the tandem use of these techniques will be explored. The real world application of these techniques during the internship will also be discussed.

  13. [Validation of the Glasgow-Blatchford Scoring System to predict mortality in patients with upper gastrointestinal bleeding in a hospital of Lima, Peru (June 2012-December 2013)].

    Science.gov (United States)

    Cassana, Alessandra; Scialom, Silvia; Segura, Eddy R; Chacaltana, Alfonso

    2015-07-01

    Upper gastrointestinal bleeding is a major cause of hospitalization and the most prevalent emergency worldwide, with a mortality rate of up to 14%. In Peru, there have not been any studies on the use of the Glasgow-Blatchford Scoring System to predict mortality in upper gastrointestinal bleeding. The aim of this study is to perform an external validation of the Glasgow-Blatchford Scoring System and to establish the best cutoff for predicting mortality in upper gastrointestinal bleeding in a hospital of Lima, Peru. This was a longitudinal, retrospective, analytical validation study, with data from patients with a clinical and endoscopic diagnosis of upper gastrointestinal bleeding treated at the Gastrointestinal Hemorrhage Unit of the Hospital Nacional Edgardo Rebagliati Martins between June 2012 and December 2013. We calculated the area under the curve for the receiver operating characteristic of the Glasgow-Blatchford Scoring System to predict mortality with a 95% confidence interval. A total of 339 records were analyzed. 57.5% were male and the mean age (standard deviation) was 67.0 (15.7) years. The median of the Glasgow-Blatchford Scoring System obtained in the population was 12. The ROC analysis for death gave an area under the curve of 0.59 (95% CI 0.5-0.7). Stratifying by type of upper gastrointestinal bleeding resulted in an area under the curve of 0.66 (95% CI 0.53-0.78) for non-variceal type. In this population, the Glasgow-Blatchford Scoring System has no diagnostic validity for predicting mortality.

  14. Validation of the Glasgow-Blatchford Scoring System to predict mortality in patients with upper gastrointestinal bleeding in a hospital of Lima, Peru (June 2012-December 2013

    Directory of Open Access Journals (Sweden)

    Alessandra Cassana

    2015-08-01

    Full Text Available Background and aim: Upper gastrointestinal bleeding is a major cause of hospitalization and the most prevalent emergency worldwide, with a mortality rate of up to 14%. In Peru, there have not been any studies on the use of the Glasgow-Blatchford Scoring System to predict mortality in upper gastrointestinal bleeding. The aim of this study is to perform an external validation of the Glasgow-Blatchford Scoring System and to establish the best cutoff for predicting mortality in upper gastrointestinal bleeding in a hospital of Lima, Peru. Methods: This was a longitudinal, retrospective, analytical validation study, with data from patients with a clinical and endoscopic diagnosis of upper gastrointestinal bleeding treated at the Gastrointestinal Hemorrhage Unit of the Hospital Nacional Edgardo Rebagliati Martins between June 2012 and December 2013. We calculated the area under the curve for the receiver operating characteristic of the Glasgow-Blatchford Scoring System to predict mortality with a 95% confidence interval. Results: A total of 339 records were analyzed. 57.5% were male and the mean age (standard deviation was 67.0 (15.7 years. The median of the Glasgow-Blatchford Scoring System obtained in the population was 12. The ROC analysis for death gave an area under the curve of 0.59 (95% CI 0.5-0.7. Stratifying by type of upper gastrointestinal bleeding resulted in an area under the curve of 0.66 (95% CI 0.53-0.78 for non-variceal type. Conclusions: In this population, the Glasgow-Blatchford Scoring System has no diagnostic validity for predicting mortality.

  15. Exploring the X-Ray Universe

    Science.gov (United States)

    Seward, Frederick D.; Charles, Philip A.

    1995-11-01

    Exploring the X-Ray Universe describes the view of the stars and galaxies that is obtained through X-ray telescopes. X-rays, which are invisible to human sight, are created in the cores of active galaxies, in cataclysmic stellar explosions, and in streams of gas expelled by the Sun and stars. The window on the heavens used by the X-ray astronomers shows the great drama of cosmic violence on the grandest scale. This account of X-ray astronomy incorporates the latest findings from several observatories operating in space. These include the Einstein Observatory operated by NASA, and the EXOSAT satellite of the European Space Agency. The book covers the entire field, with chapters on stars, supernova remnants, normal and active galaxies, clusters of galaxies, the diffuse X-ray background, and much more. The authors review basic principles, include the necessary historical background, and explain exactly what we know from X-ray observations of the Universe.

  16. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  17. Clinical Significance of Colonoscopy in Patients with Upper Gastrointestinal Polyps and Neoplasms: A Meta-Analysis

    Science.gov (United States)

    Wu, Zhen-Jie; Lin, Yuan; Xiao, Jun; Wu, Liu-Cheng; Liu, Jun-Gang

    2014-01-01

    Background Some authors have studied the relationship between the presence of polyps, adenomas and cancers of upper gastrointestinal tract (stomach and duodenum) and risk of colorectal polyps and neoplasms; however, the results are controversial, which may be due to study sample size, populations, design, clinical features, and so on. No meta-analysis, which can be generalized to a larger population and could provide a quantitative pooled risk estimate of the relationship, of this issue existed so far. Methods We performed a meta-analysis to evaluate risk of colorectal polyps or neoplasms in patients with polyps, adenomas or cancers in upper gastrointestinal tract comparing with controls. A search was conducted through PubMed, EMBASE, reference lists of potentially relevant papers, and practice guidelines up to 27 November 2013 without languages restriction. Odd ratios (ORs) were pooled using random-effects models. Results The search yielded 3 prospective and 21 retrospective case-control studies (n = 37152 participants). The principal findings included: (1) OR for colorectal polyps was 1.15 (95% CI, 1.04–1.26) in the gastric polyps group comparing with control groups; (2) Patients with gastric polyps and neoplasms have higher risk (OR, 1.31 [95% CI, 1.06–1.62], and 1.72 [95% CI, 1.42–2.09], respectively) of colorectal neoplasms comparing with their controls; and (3) Positive association was found between the presence of colorectal neoplasms and sporadic duodenal neoplasms (OR, 2.59; 95% CI, 1.64–4.11). Conclusions Findings from present meta-analysis of 24 case-control studies suggest that the prevalence of colorectal polyps was higher in patients with gastric polyps than in those without gastric polyps, and the risk of colorectal neoplasms increases significantly in patients with gastric polyps, neoplasms, and duodenal neoplasms. Therefore, screening colonoscopy should be considered for patients with upper gastrointestinal polyps and neoplasms. PMID

  18. Femtosecond X-ray magnetic circular dichroism absorption spectroscopy at an X-ray free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Higley, Daniel J., E-mail: dhigley@stanford.edu; Yuan, Edwin [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Applied Physics, Stanford University, Stanford, California 94305 (United States); Hirsch, Konstantin; Dakovski, Georgi L.; Jal, Emmanuelle; Lutman, Alberto A.; Coslovich, Giacomo; Hart, Philip; Hoffmann, Matthias C.; Mitra, Ankush; Moeller, Stefan; Ohldag, Hendrik; Seaberg, Matthew; Stöhr, Joachim; Nuhn, Heinz-Dieter; Reid, Alex H.; Dürr, Hermann A.; Schlotter, William F. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Liu, Tianmin; MacArthur, James P. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Department of Physics, Stanford University, Stanford, California 94305 (United States); and others

    2016-03-15

    X-ray magnetic circular dichroism spectroscopy using an X-ray free electron laser is demonstrated with spectra over the Fe L{sub 3,2}-edges. The high brightness of the X-ray free electron laser combined with high accuracy detection of incident and transmitted X-rays enables ultrafast X-ray magnetic circular dichroism studies of unprecedented sensitivity. This new capability is applied to a study of all-optical magnetic switching dynamics of Fe and Gd magnetic sublattices in a GdFeCo thin film above its magnetization compensation temperature.

  19. Emergency arterial embolization of upper gastrointestinal and jejunal tumors: An analysis of 12 patients with severe bleeding.

    Science.gov (United States)

    Zandrino, F; Tettoni, S M; Gallesio, I; Summa, M

    2017-01-01

    The goal of this study was to retrospectively assess the efficacy of emergency percutaneous transcatheter arterial embolization in patients with severe bleeding due to upper gastrointestinal or jejunal tumor. Twelve patients (7 men, 5 women; mean age, 74 years±14 (SD); range: 54-86 years) with severe bleeding from the upper gastrointestinal tract, with failed endoscopic treatment not eligible for emergency surgery were treated by emergency percutaneous transcatheter arterial embolization. The bleeding cause was gastric tumor in 7 patients, duodenal tumor in 4 patients and jejunal tumor in one patient. Procedure details and follow-up were reviewed. Twelve embolization procedures were performed using various embolic agents. Embolization was achieved and bleeding was stopped in all patients. Five patients underwent surgery within the 30 days following embolization. In the remaining 7 patients, no bleeding occurred at 1 month follow-up in 6 patients and bleeding recurred in one patient at 1 month. In this later patient, endoscopic treatment was successful. The results of our study suggest that transcatheter arterial embolization is safe and effective in patients with severe arterial bleeding due to upper gastrointestinal or jejunal tumor. In some patients, transcatheter arterial embolization can be used as a bridge to surgery. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  20. Distortion of absorption-line velocity curves due to x-ray heating in x-ray binaries

    International Nuclear Information System (INIS)

    Milgrom, M.

    1976-01-01

    The effects of X-ray heating on the measured absorption line velocities, in X-ray binaries with low X-rays to optical luminosities ratio are considered. These effects may be appreciable even for such binaries where the effect of X-ray heating on the light-curve is negligible. The effects are studied qualitatively and suggest possible ways to partially eliminate the systematic errors introduced by them. The individual systems Cyg x-1 and SMC x-1 are treated and the results of numerical calculations are presented for them. For Cyg x-1 it is found that the effect is detectable during the X-ray 'high' state in all regions of the spectrum. During the 'low' state it may be important in the red region of the spectrum. The results for the case in which soft X-ray fluxes (E < or approximately .4 keV, suggested by theoretical models) are present are also given. For SMC x-1 a strong effect for Hα, Hβ, Hγ had been found. This effect may be responsible for the observed variable velocity curve. We also find for SMC x-1 that the average X-ray intensity falling on the primary must be considerably smaller than what is derived from the detected flux, or else the effect is too large. (author)