WorldWideScience

Sample records for universal measuring equipment

  1. EMR Measurements on NDA Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Macdonell, Alexander Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meierbachtol, Krista Cruse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Evans, James Walter Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mayo, Douglas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

  2. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  3. Temperature radiation measuring equipment. Temperaturstrahlungsmessgeraet

    Energy Technology Data Exchange (ETDEWEB)

    Lotzer, W

    1981-01-22

    The invention is concerned with a temperature radiation measuring equipment for non-contact temperature measurement by the light intensity variation method, with a photoelectric resistance as the measuring element. By having a circuit with a transistor, the 'dark resistance' occurring in the course of time is compensated for and thus gives a genuine reading (ie. the voltage drop across the photoelectric resistance remains constant).

  4. Market survey of level measurement equipment

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    In a market survey of level measurement equipment from 42 manufacturers, which is based on different principles of measurement and which is used for different applications, the data of the various manufacturers is compiled. (orig./HP) [de

  5. Development of Turbulence-Measuring Equipment

    Science.gov (United States)

    Kovasznay, Leslie S G

    1954-01-01

    Hot wire turbulence-measuring equipment has been developed to meet the more stringent requirements involved in the measurement of fluctuations in flow parameters at supersonic velocities. The higher mean speed necessitates the resolution of higher frequency components than at low speed, and the relatively low turbulence level present at supersonic speed makes necessary an improved noise level for the equipment. The equipment covers the frequency range from 2 to about 70,000 cycles per second. Constant-current operation is employed. Compensation for hot-wire lag is adjusted manually using square-wave testing to indicate proper setting. These and other features make the equipment adaptable to all-purpose turbulence work with improved utility and accuracy over that of older types of equipment. Sample measurements are given to demonstrate the performance.

  6. University scientists test Mars probe equipment

    CERN Multimedia

    2002-01-01

    Scientists at Leicester University have spent four years researching and designing the Flight Model Position Adjustable Workbench (PAW) at the university. It will be attached to the Beagle 2 probe before being sent to the Red Planet in the spring (1/2 page).

  7. Performance Measurement at Universities

    DEFF Research Database (Denmark)

    Lueg, Klarissa

    2014-01-01

    This paper proposes empirical approaches to testing the reliability, validity, and organizational effectiveness of student evaluations of teaching (SET) as a performance measurement instrument in knowledge management at the institutional level of universities. Departing from Weber’s concept...

  8. Effects of measurement procedure and equipment on average room acoustic measurements

    DEFF Research Database (Denmark)

    Gade, Anders Christian; Bradley, J S; Siebein, G W

    1993-01-01

    This paper reports the results of a measurement tour of nine U.S. concert halls. Three measurements teams, from the University of Florida, the National Research Council of Canada, and the Technical University of Denmark, made parallel sets of measurements using their own equipment and procedures........ [Work partially supported by the Concert Hall Research Group.]......This paper reports the results of a measurement tour of nine U.S. concert halls. Three measurements teams, from the University of Florida, the National Research Council of Canada, and the Technical University of Denmark, made parallel sets of measurements using their own equipment and procedures....... In some of the halls measurements were repeated using the procedures of the other teams to make it possible to separate the effects of different equipment and different procedures. The paper will present position-averaged results from the three teams and will discuss reasons for the differences observed...

  9. Magnet measuring equipment of SC2

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    Checking the positioning of the magnet measuring equipment installed between the poles of SC2. The steel structure in front of the magnet is designed to house the rotary condenser and to shield it from the stray magnetic field of the accelerator.

  10. Magnet measuring equipment of SC2

    CERN Multimedia

    1974-01-01

    Checking the positioning of the magnet measuring equipment installed between the poles of SC2. The steel structure in front of the magnet is designed to house the rotary condenser and to shield it from the stray magnetic field of the accelerator. On the left, Marinus van Gulik. (See Photo Archive 7402005 and Annual Report 1974, p. 44.)

  11. Mechanical equipment for magnet measurement and alignment

    International Nuclear Information System (INIS)

    Harvey, A.

    1992-05-01

    The mechanical equipment for measuring and aligning (or fiducializing) magnets is described by reference to devices designed and built by a number of laboratories. Some of these are now available commercially. The descriptions are supplemented by a list of representative sources of hardware

  12. Equipment for liquid metal pressure measurement

    International Nuclear Information System (INIS)

    Jung, J.

    1977-01-01

    Equipment is proposed for measuring liquid metal pressure in piping or a tank. An auxiliary piping is connected to the piping or tank at the measuring point. The auxiliary piping transports liquid metal to a container by means of an electromagnetic pump. The piping also houses an electromagnetic flow ratemeter connected to an electric comparator. The comparator and the electromagnetic pump are connected to the pump output generator. (Z.M.)

  13. Laser-based measuring equipment controlled by microcomputer

    International Nuclear Information System (INIS)

    Miron, N.; Sporea, D.; Velculescu, V.G.; Petre, M.

    1988-03-01

    Some laser-based measuring equipment controlled by microcomputer developed for industrial and scientific purposes are described. These equipments are intended for dial indicators verification, graduated rules measurement, and for very accurate measurement of the gravitational constant. (authors)

  14. UV-treatment in dermatology. Equipment and methods in Norwegian university hospitals

    International Nuclear Information System (INIS)

    Christensen, T.; Johnsen, B.; Johnsson, M.; Nordal, E.; Thune, P.; Kjeldstad, B.; Reitan, J.B.

    1994-12-01

    The use of phototherapy and the phototherapy-equipment were studied in five Norwegian university hospitals. The indications and the methods used were relatively similar, as well as the equipment used for dosimetry. The spectra and irradiance from the phototherapy lamps were measured and the variations in these parameters were evaluated. It is discussed whether there is a need for closer control and standardization of these parameters. The UVA-irradiance that could be experienced by the persons employed in the departments was found to be lower than the recommended limits. 12 refs., 7 figs., 6 tabs

  15. Equipment Development for Automatic Anthropometric Measurements

    Science.gov (United States)

    Cater, J. P.; Oakey, W. E.

    1978-01-01

    An automated procedure for measuring and recording the anthropometric active angles is presented. The small portable system consists of a microprocessor controlled video data acquisition system which measures single plane active angles using television video techniques and provides the measured data on sponsored-specified preformatted data sheets. This system, using only a single video camera, observes the end limits of the movement of a pair of separated lamps and calculates the vector angle between the extreme positions.

  16. Precision density measuring equipment: Design, selected examples

    International Nuclear Information System (INIS)

    Karasinski, T.; Patzelt, K.; Dieker, C.; Hansen, H.; Wenzl, H.; Schober, T.

    1987-06-01

    The report deals with solids density measurement using the pyknometer, the hydrostatic balance, or the floating specimen method. The mathematical relations are derived, and error sources are shown. A detailed description is given of a measuring set-up for measuring the density of solids and liquids. An error calculation is presented. After explaining the determination of density of a standard solid body, the report describes the density measurement of monocrystalline germanium, of niobium-tritide, Ni 3 Al, Ge-Si, and gallium arsenide, the determination of space-lattice expansion by hydrogen isotopes, and of the purity of H-D mixtures. (GG) [de

  17. Mobile equipment for measurement of gamma radiation

    International Nuclear Information System (INIS)

    2009-01-01

    NRPA has several systems to perform mobile measurements. One of the systems consists of detectors mounted on the roof of a car. Mobile systems can be used to map the radioactive contamination of large areas in a short time, to the reference measurements and to search for sources astray. The systems can be mounted on the vehicle or used in a helicopter or airplane. (AG)

  18. Performance Measurement of Mining Equipments by Utilizing OEE

    Directory of Open Access Journals (Sweden)

    Sermin Elevli

    2010-10-01

    Full Text Available Over the past century, open pit mines have steadily increased their production rate by using larger equipments which requireintensive capital investment. Low commodity prices have forced companies to decrease their unit cost by improving productivity. Oneway to improve productivity is to utilize equipment as effectively as possible. Therefore, the accurate estimation of equipmenteffectiveness is very important so that it can be increased. Overall Equipment Effectiveness (OEE is a well-known measurementmethod, which combines availability, performance and quality, for the evaluation of equipment effectiveness in manufacturing industry.However, there isn’t any study in literature about how to use this metric for mining equipments such as shovel, truck, drilling machineetc. This paper will discuss the application of OEE to measure effectiveness of mining equipment. It identifies causes of time losses forshovel and truck operations and introduces procedure to record time losses. The procedure to estimate OEE of shovels and trucks hasalso been presented via numerical example.

  19. Vibration Measurement with PULSE and DSPACE Equipment

    Directory of Open Access Journals (Sweden)

    Radim KLEČKA

    2009-06-01

    Full Text Available This contribution describes techniques and results of measurement with TIRA vibration generator. A method of experimental modal analysis allows next restore of vibration data. The goal is check validity of head expanders and screw connection. This process is based to using ME’scope environment. Another goal is check possibilities of dSPACE platform to vibration measurement. This task includes design of connection between dSPACE system and power amplifier, creating of graphical user interface and analyzing main configuration parameters to improve quality of drive signal.

  20. Development of an Equipment for Measuring OSL

    International Nuclear Information System (INIS)

    Chung, Ki Soo; Choe, Hong Soo

    2010-05-01

    A measurement system optically simulated luminescence (OSL) and thermoluminescence (TL) is developed. The system is composed by stimulation light part assembled by 3 ea of high brightness blue LEDs, temperature control system which can be controlled from room temperature to 300 .deg. C and filter package for separation of OSL and stimulation light with GG-420 and U-340 optical filters. The system was tested using Al 2 O 3 C OSL samples and a typical OSL curves were obtained. In addition, several OSL curves from LiAlO 2 C (a candidate of new OSLD material) were obtained and analyzed. A new algorithm for analysis of OSL curve and software (TOLAnal, Windows based) is developed and tested

  1. Equipment of Thomson scattering measurement on DIVA plasma

    International Nuclear Information System (INIS)

    Yamauchi, Toshihiko; Kumagai, Katsuaki; Funahashi, Akimasa; Matoba, Thoru; Sengoku, Seio

    1980-02-01

    Equipment of Thomson scattering measurement using ruby-laser light is explained. DIVA device was shut down in September 1979; it gave numerous fruitful experimental results during its five years operation. We measured the profiles of electron temperature and density with the Thomson scattering equipment, which played an important role in research of the energy confinement and heating characteristics. In Thomson scattering measurements on DIVA, studies and improvements were made for reduction of stray light, increase of measuring points and data processing. The profile of electron temperature and density were thus measured successful. In this report is given an over-all view of the Thomson scattering equipment together with the above improvements. As two representative examples, the measured results of electron temperature profiles on DIVA plasma under divertor operation and low-q discharge respectively are described. (author)

  2. Prophylactic and thermovision measurements of electric machines and equipment

    International Nuclear Information System (INIS)

    Jedlicka, R.; Brestovansky, L.

    1996-01-01

    High-voltage measurements of generators, unit and service transformers and some significant motor drives used at a nuclear power plant are described in this paper. Thermovision measurements of electric machines and distribution systems are dealt with in the second part of the paper. Power electric equipment represent one of the most significant components of a nuclear power plant. Turbine mechanical energy is converted into the electrical energy within these equipment. Power generated by generators is transformed by transformers so that it can achieve appropriate parameters for both the transmission over the distribution system and the power plant service power supply. The service power supply switchboards and cables provide supply to motors and other consumers necessary for the nuclear power plant technological process. The whole complex of equipment has to be maintained in good technical conditions. It is necessary to make thermovision and prophylactic measurements to identify and verify the electric equipment technical condition. The mentioned measurements warn the operation staff in advance against both gradual deterioration of power connection contact resistances, i.e. power connections overheating, and the machine insulation systems condition deterioration. The operation staff try to prevent the electric equipment operation accidents by early removing the detected failures, thus, improving the nuclear safety. In order to provide the above-mentioned activities a special prophylactic measurement group was established at the NPP Bohunice in 1983. The group specialists make following types of measurements. 1. Prophylactic measurements of electric machines. Prophylactics of 220 MW generators and 6 MW service power generators; Prophylactics of both unit and service transformers and VHV bushings; Prophylactics of major 6 kV motor drives. 2. Thermovision measurements of current connections. Measurements enumarated in paragraph 1 are made on disconnected electric

  3. Utilization of old vibro-acoustic measuring equipment to grasp basic concepts of vibration measurements

    DEFF Research Database (Denmark)

    Darula, Radoslav

    2013-01-01

    The aim of the paper is to show that even old vibro-acoustic (analog) equipment can be used as a very suitable teaching equipment to grasp basic principles of measurements in an era, when measurement equipments are more-or-less treated as ‘black-boxes’, i.e. the user cannot see directly how...

  4. Prophylactic and thermovision measurements of electric machines and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Jedlicka, R; Brestovansky, L [Atomova Elektraren Bohunice, Jaslovske Bohunice (Slovakia)

    1997-12-31

    High-voltage measurements of generators, unit and service transformers and some significant motor drives used at a nuclear power plant are described in this paper. Thermovision measurements of electric machines and distribution systems are dealt with in the second part of the paper. Power electric equipment represent one of the most significant components of a nuclear power plant. Turbine mechanical energy is converted into the electrical energy within these equipment. Power generated by generators is transformed by transformers so that it can achieve appropriate parameters for both the transmission over the distribution system and the power plant service power supply. The service power supply switchboards and cables provide supply to motors and other consumers necessary for the nuclear power plant technological process. The whole complex of equipment has to be maintained in good technical conditions. It is necessary to make thermovision and prophylactic measurements to identify and verify the electric equipment technical condition. The mentioned measurements warn the operation staff in advance against both gradual deterioration of power connection contact resistances, i.e. power connections overheating, and the machine insulation systems condition deterioration. The operation staff try to prevent the electric equipment operation accidents by early removing the detected failures, thus, improving the nuclear safety. In order to provide the above-mentioned activities a special prophylactic measurement group was established at the NPP Bohunice in 1983. The group specialists make following types of measurements. 1. Prophylactic measurements of electric machines. Prophylactics of 220 MW generators and 6 MW service power generators; Prophylactics of both unit and service transformers and VHV bushings; Prophylactics of major 6 kV motor drives. 2. Thermovision measurements of current connections. (Abstract Truncated)

  5. Low-energy house in Sisimiut - Measurement equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hvidthoeft Delff Andersen, P.; Rode, C.; Madsen, Henrik

    2013-08-15

    This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit, experiments can be designed in order to study heat dynamics of the building. It is described how to plan and execute such experiments in one apartment in the building. The building also features both a solar thermal system and extra buffer tank facilitating testing of storage strategies on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented to fetch and prepare the data for time series analysis. Examples are given on the use of these. (Author)

  6. Measurement problem in PROGRAM UNIVERSE

    International Nuclear Information System (INIS)

    Noyes, H.P.; Gefwert, C.

    1984-12-01

    We present a discrete theory that meets the measurement problem in a new way. We generate a growing universe of bit strings, labeled by 2 127 + 136 strings organized by some representation of the closed, four level, combinatorial hierarchy, of bit-length N 139 greater than or equal to 139. The rest of the strings for each label, which grow in both length and number, are called addresses. The generating algorithm, called PROGRAM UNIVERSE, starts from a random choice between the two symbols ''0'' and ''1'' and grows (a) by discriminating between two randomly chosen strings and adjoining a novel result to the universe, or when the string so generated is not novel, by (b) adjoining a randomly chosen bit at the growing end of each string. We obtain, by appropriate definitions and interpretations, stable ''particles'' which satisfy the usual relativistic kinematics and quantized angular momentum without being localizable in a continuum space-time. The labeling scheme is congruent with the ''standard model'' of quarks and leptons with three generations, but for the problem at hand, the implementation of this aspect of the theory is unimportant. What matters most is that (a) these complicated ''particles'' have the periodicities familiar from relativistic ''deBroglie waves'' and resolve in a discrete way the ''wave-particle dualism'' and (b) can be ''touched'' by our discrete equivalent of ''soft photons'' in such a way as to follow, macroscopically, the usual Rutherford scattering trajectories with the associated bound states. Thus our theory could provide a discrete description of ''measurement'' in a way that allows no conceptual barrier between the ''micro'' and the ''macro'' worlds, if we are willing to base our physics on counting and exclude the ambiguities associated with the unobservable ''continuum''. 27 refs

  7. Listing of solar radiation measuring equipment and glossary

    Science.gov (United States)

    Carter, E. A.; Greenbaum, S. A.; Patel, A. M.

    1976-01-01

    An attempt is made to list and provide all available information about solar radiation measuring equipment which are being manufactured and are available on the market. The list is in tabular form and includes sensor type, response time, cost data and comments for each model. A cost code is included which shows ranges only.

  8. Attribute measurement systems prototypes and equipment in the United States

    International Nuclear Information System (INIS)

    Langner, D.C.; Landry, R.P.; Hsue, S.-T.; MacArthur, D.W.; Mayo, D.R.; Smith, M.K.; Nicholas, N.J.; Whiteson, R.

    2001-01-01

    Since the fall of 1997, the United States has been developing prototypical attribute verification technology for potential use by the International Atomic Energy Agency (IAEA) under the Trilateral Initiative. The first attribute measurement equipment demonstration took place in December 1997 at the Lawrence Livermore National Laboratory. This demonstration led to a series of joint Russian Federatioin/US/IAEA technical discussions that focused on attribute measurement technology that could be applied to plutonium bearing items having classified characteristics. A first prototype attribute verification system with an information barrier was demonstrated at a Trilateral Technical Workshop in June 1999 at Los Alamos. This prototype nourished further fruitful discussions between the three parties that has in turn led to the documents discussed in a previous paper. Prototype development has continued in the US, under other initiatives, using an integrated approach that includes the Trilatleral Initiative. Specifically for the Trilateral Initiative, US development has turned to some peripheral equipment that would support verifications by the IAEA. This equipment includes an authentication tool for measurement systems with information barriers and in situ probes that would facilitate inspections by reducing the need to move material out of storage locations for reverification. In this paper, we will first summarize the development of attribute verification measurement system technology in the US and then report on the status of the development of other equipment to support the Trilateral Initiative.

  9. Measurement and control system for ITER remote maintenance equipment

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Kiyoshi; Kakudate, Satoshi; Takeda, Nobukazu; Takiguchi, Yuji; Akou, Kentaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-04-01

    ITER in-vessel components such as blankets and divertors are categorized as scheduled maintenance components because they are subjected to severe plasma heat and particle loads. Blanket maintenance requires remote handling equipment and tools able to handle Heavy payloads of about 4 tons within a 2 mm precision tolerance. Divertor maintenance requires remote replacement of 60 cassettes with a dead weight of about 25 tons each. In the ITER R and D program, full-scale remote handling equipment for blanket and divertor maintenance has been designed and assembled for demonstration tests. This paper reviews the measurement and control system developed for full-scale remote handling equipment, the Japan Home Team contribution. (author)

  10. Measurement and control system for ITER remote maintenance equipment

    International Nuclear Information System (INIS)

    Oka, Kiyoshi; Kakudate, Satoshi; Takeda, Nobukazu; Takiguchi, Yuji; Akou, Kentaro

    1998-01-01

    ITER in-vessel components such as blankets and divertors are categorized as scheduled maintenance components because they are subjected to severe plasma heat and particle loads. Blanket maintenance requires remote handling equipment and tools able to handle Heavy payloads of about 4 tons within a 2 mm precision tolerance. Divertor maintenance requires remote replacement of 60 cassettes with a dead weight of about 25 tons each. In the ITER R and D program, full-scale remote handling equipment for blanket and divertor maintenance has been designed and assembled for demonstration tests. This paper reviews the measurement and control system developed for full-scale remote handling equipment, the Japan Home Team contribution. (author)

  11. Special equipment for processing can-rupture measurements; Equipement specialise de traitement des mesures de rupture de gaines

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, J.; Phalippou, J.; Dumont, D.; Viellard, R. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Recent installations for detecting can-rupture in nuclear reactors use, in the measurement processing section, a digital computer, either completely or partially. The reliability of the system is limited by that of the computer, which represents a common point for the processing of data from the detector. In order to satisfy the demands imposed by safety considerations for the operation of the equipment it is necessary to consider the possibility of installing a second computer in certain cases. The use of a computer involves the presence as interface between the detection equipment and the computer itself, of sealers operating as integrators for the pulses produced by the detector. By adding a certain number of circuits to these sealers, it is possible to carry out the work now demanded of the computer, as far as the calculation is concerned. This reasoning has led us to a so-called 'decentralized' solution involving the construction of specialized equipment in the region of the prospector itself. We believe that this solution, apart from the reliability point of view, has definite economic advantages. In our solution, the common point in the processing of the data is now situated not in the zone of the production of results but further down, in the printing out of these results. Even in the case of an incident at the common point, the results are produced, exposed and compared to the alarm thresholds. In the case of a breakdown of the specialized equipment, the results from this prospector are no longer available but the others continue to operate. It seems that this solution is more reliable than that employing universal computers. By using an interchangeable drawer system (MULTIBLOC) it is possible to replace rapidly any of the specialized equipment which breaks down. The systematic use of integrated circuits (TTL) ensures an increased reliability of the equipment. (author) [French] Les installations recentes de detection de rupture de gaines

  12. Universal Authenticated Item Monitoring System (AIMS) second generation equipment

    International Nuclear Information System (INIS)

    Schoeneman, J.L.; Baumann, M.J.; Fox, L.J.; Jenkins, C.D.; Perlinsk, A.W.

    1992-01-01

    Sandia National Laboratories (SNL) is in the final stages of developing a Universal Authenticated Item Monitoring System (AIMS). When completed, AIMS will provide applicable agencies in the US government, and those in the International arena, with a secure and convenient method of monitoring the physical status of selected items. The benefit derived from this development activity will be the commercial availability of an item monitoring system with the capability for ''quick set-up'' monitoring, as well as long-term unattended monitoring. The AIMS includes a variety of sensors, a robust and authenticated radio frequency (RF) communication link, a Receiver Processing Unit (RPU), and an inspector-friendly personal computer (PC) interface for collecting, sorting, viewing and archiving pertinent event histories. The system will provide the capability to monitor selected items in a real-time mode, a remotely interrogated mode, and a stand-alone, unattended data collection mode. The sensor suite under development includes advanced motion sensors, interior volumetric intrusion sensors, Re-usable, In-situ Verifiable Authenticated (RIVA) fiber-optic seal sensors, generic utility sensors (to accommodate contact closure inputs), and radiation and environmental sensors. A new generation authentication algorithm recently has been developed that provides a high degree of system security 121. The AIMS has potential safeguards applications in the areas of arms control and treaty verification military asset control, International Atomic Energy Agency (IAEA) and Euratom safeguards verification activities, as well as domestic nuclear safeguard activities. Commercial applications could include high-value inventory control and security systems. This paper describes the second-generation AIMS along with its recently expanded sensor suite and enhanced data collection capabilities

  13. Establishment of Experimental Equipment for Training of Professionals in the Nuclear Radiation Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, S. K.; Seo, K. W.; Joo, Y. C.; Kim, I. C.; Woo, C. K.; Yoo, B. H. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-09-15

    The main purpose of this project is to establish experimental equipment for training of professionals and students in the field of radiation measurement, and settle the foundation for the advanced education system and program. The priority for the experimental equipment had been deduced by reviewing of the Nuclear Training and Education Center of KAERI and other country's training courses. Equipment for training of radiation professionals are High-Purity Germanium spectroscopic systems, alpha analyzers, and hand-held gamma/neutron inspector systems. For the basic experiments, electric personal dosimeters and a reader, radiation survey meters, and various alpha, beta and gamma radiation isotopes have been equipped. Some old or disused equipment and devices were disposed and re-arranged, and a new experiment lab had been settled for gamma spectroscopy. Along with the preparation of equipment, 14 experimental modules have been selected for practical and essential experiments training to professionals from industries, universities and research organizations. Among the modules, 7 important experiment notes had been prepared in Korea and also in English. As a consequence, these advanced radiation experimental setting would be a basis to cooperate with IAEA or other countries for international training courses. These activities would be a foundation for our contribution to the international nuclear society and for improving our nuclear competitiveness. The experimental equipment and application notes developed in this study will be used also by other training institutes and educational organizations through introducing and encouraging to use them to the nuclear society.

  14. Establishment of Experimental Equipment for Training of Professionals in the Nuclear Radiation Measurement

    International Nuclear Information System (INIS)

    Ahn, S. K.; Seo, K. W.; Joo, Y. C.; Kim, I. C.; Woo, C. K.; Yoo, B. H.

    2008-09-01

    The main purpose of this project is to establish experimental equipment for training of professionals and students in the field of radiation measurement, and settle the foundation for the advanced education system and program. The priority for the experimental equipment had been deduced by reviewing of the Nuclear Training and Education Center of KAERI and other country's training courses. Equipment for training of radiation professionals are High-Purity Germanium spectroscopic systems, alpha analyzers, and hand-held gamma/neutron inspector systems. For the basic experiments, electric personal dosimeters and a reader, radiation survey meters, and various alpha, beta and gamma radiation isotopes have been equipped. Some old or disused equipment and devices were disposed and re-arranged, and a new experiment lab had been settled for gamma spectroscopy. Along with the preparation of equipment, 14 experimental modules have been selected for practical and essential experiments training to professionals from industries, universities and research organizations. Among the modules, 7 important experiment notes had been prepared in Korea and also in English. As a consequence, these advanced radiation experimental setting would be a basis to cooperate with IAEA or other countries for international training courses. These activities would be a foundation for our contribution to the international nuclear society and for improving our nuclear competitiveness. The experimental equipment and application notes developed in this study will be used also by other training institutes and educational organizations through introducing and encouraging to use them to the nuclear society

  15. Equipment for the measurement of non-electrical parameters

    International Nuclear Information System (INIS)

    Lewin, M.I.; Ewtuchow, A.N.

    1977-01-01

    The invention concerns equipment for the measurement of non-electrical parameters, which can be used in data processing and control equipment. The transducer converts non-electrical parameters into electrical signals. The process according to the invention is explained using the example of an inductive transducer, which is fed with alternating current. The measured parameter affects the mutual inductance of the transducer, so that the secondary voltage supplied by it is a function of the measured parameter. Amplitude measurement of this voltage by means of rectification and filtering has the disadvantage of long time constants, where the measuring period would amount to 6 to 10 cycles of the supply voltage. According to the invention the secondary voltage of the transducer is connected to an integrator during a half-cycle between two zeros, which charges a capacitor to a voltage proportional to the amplitude. An analogue-digital converter now produces a digital signal corresponding to the capacitor voltage, which is taken to the control equipment. This conversion occurs during a fraction of the second half-cycle, so that there is still time before the end of this half-cycle, so that there is still time before the end of this half-cycle to discharge the capacitor and to reproduce the initial conditions. In the next cycle the whole process is repeated, so that the measuring process only takes one cycle. In order to make the digital signal independent of the amplitude of the current fed in, this also flows through an identical transducer with constant mutual inductance, and affects the analogue-digital converter via a comparative circuit. (ORU) [de

  16. Remotely-operated equipment for inspection, measurement and handling

    CERN Document Server

    Bertone, C; CERN. Geneva. TS Department

    2008-01-01

    As part of the application of ALARA radiation dose reduction principles at CERN, inspection, measurement and handling interventions in controlled areas are being studied in detail. A number of activities which could be carried out as remote operations have already been identified and equipment is being developed. Example applications include visual inspection to check for ice formation on LHC components or water leaks, measurement of radiation levels before allowing personnel access, measurement of collimator or magnet alignment, visual inspection or measurements before fire service access in the event of fire, gas leak or oxygen deficiency. For these applications, a modular monorail train, TIM, has been developed with inspection and measurement wagons. In addition TIM provides traction, power and data communication for lifting and handling units such as the remote collimator exchange module and vision for other remotely operated units such as the TAN detector exchange mini-cranes. This paper describes the eq...

  17. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  18. Connecticut State University System Initiative for Nanotechnology-Related Equipment, Faculty Development and Curriculum Development

    Energy Technology Data Exchange (ETDEWEB)

    Broadbridge, Christine C. [Southern Connecticut State University

    2013-03-28

    DOE grant used for partial fulfillment of necessary laboratory equipment for course enrichment and new graduate programs in nanotechnology at the four institutions of the Connecticut State University System (CSUS). Equipment in this initial phase included variable pressure scanning electron microscope with energy dispersive x-ray spectroscopy elemental analysis capability [at Southern Connecticut State University]; power x-ray diffractometer [at Central Connecticut State University]; a spectrophotometer and spectrofluorimeter [at Eastern Connecticut State University; and a Raman Spectrometer [at Western Connecticut State University]. DOE's funding was allocated for purchase and installation of this scientific equipment and instrumentation. Subsequently, DOE funding was allocated to fund the curriculum, faculty development and travel necessary to continue development and implementation of the System's Graduate Certificate in Nanotechnology (GCNT) program and the ConnSCU Nanotechnology Center (ConnSCU-NC) at Southern Connecticut State University. All of the established outcomes have been successfully achieved. The courses and structure of the GCNT program have been determined and the program will be completely implemented in the fall of 2013. The instrumentation has been purchased, installed and has been utilized at each campus for the implementation of the nanotechnology courses, CSUS GCNT and the ConnSCU-NC. Additional outcomes for this grant include curriculum development for non-majors as well as faculty and student research.

  19. Assessing the Oldness and Capacity of Radiography and Ultrasound Equipments in Tehran University of Medical Sciences

    International Nuclear Information System (INIS)

    Salamati, Payman; Ghanaati, Hossein; Ghasemzadeh, Shahram; Jalali, Amir Hossein

    2013-01-01

    Maintenance of imaging equipment is a very important part of the management of all medical imaging centers. To assess the oldness and capacity of radiography and ultrasound equipment in Tehran University of Medical Sciences. The study was performed in 16 hospitals, 4 faculties and three healthcare centers of Tehran University of Medical Sciences. We evaluated all the X-ray equipment (including the simple plain and dental, panorex, mammography, fluoroscopy and C-arm X-Ray devices) and also simple and Doppler ultrasound machines in terms of the type and usage of the device, production year, quantity of utilization, location, brand and current condition. Among fixed X-ray systems, 15 were currently in use, two were junk, two were damaged, and one was not utilized. The mean (SD) of the usage of these was 2151 (2230) cliché/month, and the mean (SD) of the oldness was 16.9 (13.6) years. The oldness of radiography equipment in our study was more than 20 years in 16, between 11 and 20 in 46, and less than 10 years in 76 devices. The mean (SD) usage (patients/month) of simple and color Doppler devices were 234.1 (365.2) and 597.5 (505.3), respectively. The oldness of ultrasonography equipment in our study was more than 11 years in 12 and less than 10 years in 55 devices. We found that 22 (15.9%) of the radiography systems and two (3%) of the ultrasonography systems had been used for more than 20 years. Radiology equipment in Tehran University of Medical Sciences have potential capacity, but they need repair, and better maintenance and management and application of standards for the imaging system needs organized supervisory mechanisms

  20. Density measurement by means of once scattered gamma radiation the ETG probe, principles and equipment

    International Nuclear Information System (INIS)

    Joergensen, J.L.; Oelgaard, P.L.; Berg, F.

    1987-01-01

    The Department of Electrophysics, the Technical University of Denmark, and the Danish National Road Laboratory have together developed a new patent claimed device for measurements of the in situ density of materials. This report describes the principles of the system and some experimental results. The system is based on the once scattered gamma radiation. In a totally non-destructive and fast way it is possible to measure the density of up to 25 cm thick layers. Furthermore, an estimate of the density variation through the layer may be obtained. Thus the gauge represents a new generation of equipment for e.g. compaction control of road constructions. (author)

  1. Tohoku University radiocarbon measurements, 6

    International Nuclear Information System (INIS)

    Omoto, Kunio

    1978-01-01

    With check, geomorphic, geologic, archaeological and foreign samples, the 14 C ages reported were mostly measured between November, 1977, and April, 1978. Age measurement and sample processing were the same as before. TH-207 and following dates were measured with a new set of amplifier units and high voltage units linked with Canon SX-350 computer system. Age calculations were based on the contemporary value equal to 95 percent of the activity of NBS oxalic acid standard and on the conventional half-life for 14 C of 5,570 +- 30 years. The results are represented in years before 1950 (years BP). Errors quoted were calculated on the basis of one standard deviation in the statistical error of counting rate of the samples. Sample descriptions are based on the information provided by the submitter. (Mori, K.)

  2. Equipment for fully homologous bulb turbine model testing in Laval University

    International Nuclear Information System (INIS)

    Fraser R; Vallée D; Jean Y; Deschênes C

    2014-01-01

    Within the context of liberalisation of the energy market, hydroelectricity remains a first class source of clean and renewable energy. Combining the growing demand of energy, its increasing value and the appreciation associated to the sustainable development, low head sites formerly considered as non-profitable are now exploitable. Bulb turbines likely to equip such sites are traditionally developed on model using right angle transmission leading to piers enlargement for power take off shaft passage, thus restricting possibilities to have fully homologous hydraulic passages. Aiming to sustain good quality development on fully homologous scale model of bulb turbines, the Hydraulic Machines Laboratory (LAMH) of Laval University has developed a brake with an enhanced power to weight ratio. This powerful brake is small enough to be located in the bulb shell while dissipating power without mandatory test head reduction. This paper first presents the basic technology of this brake and its application. Then both its main performance capabilities and dimensional characteristics will be detailed. The instrumentation used to perform accurate measurements will be finally presented

  3. Validation Testing for Automated Solubility Measurement Equipment Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lachut, J. S. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2016-01-11

    Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride did not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.

  4. University building safety index measurement using risk and implementation matrix

    Science.gov (United States)

    Rahman, A.; Arumsari, F.; Maryani, A.

    2018-04-01

    Many high rise building constructed in several universities in Indonesia. The high-rise building management must provide the safety planning and proper safety equipment in each part of the building. Unfortunately, most of the university in Indonesia have not been applying safety policy yet and less awareness on treating safety facilities. Several fire accidents in university showed that some significant risk should be managed by the building management. This research developed a framework for measuring the high rise building safety index in university The framework is not only assessed the risk magnitude but also designed modular building safety checklist for measuring the safety implementation level. The safety checklist has been developed for 8 types of the university rooms, i.e.: office, classroom, 4 type of laboratories, canteen, and library. University building safety index determined using risk-implementation matrix by measuring the risk magnitude and assessing the safety implementation level. Building Safety Index measurement has been applied in 4 high rise buildings in ITS Campus. The building assessment showed that the rectorate building in secure condition and chemical department building in beware condition. While the library and administration center building was in less secure condition.

  5. Measurement of the residence time distribution in industrial flotation equipment

    International Nuclear Information System (INIS)

    Yianatos, Juan; Diaz, F; Rodriguez, Jorge

    2003-01-01

    This work presents a determination of the effective liquid and solid residence time in mechanical cell banks of primary and sweep flotation, and in cleaning flotation columns, at Codelco-Chile's Salvador Division. The determination was carried out using the residence time distribution (RTD) measurement with radioactive tracers. Br-82 was used as the trace element for the liquid. Different kinds of minerals were used to trace the solid: a) activated global tailing (non floatable), b) tailing activated by size classifications (non floatable) and c) activated floatable mineral. The residence time measurement defined effective volumes of 50-80% of the total volume in flotation cell banks, and effective volumes of 77% of the total volume of large-size flotation solids. The effective residence time of the solid (23%+212 microns) in industrial flotation cell banks was 5% below that for the liquid. The residence time of the mineral decreased with increased particle size. Thick mineral (>150 microns) showed a residence time 8% below that for thin mineral (<45 microns). The RTD of industrial mechanical cell banks is adequately represented with a number of perfect mixers in series equivalent to the number of real bank cells. The RTD of the industrial columns equals less than two perfect mixers in series and adjusts better when considering a perfect mixers in series model, but in a different size. Common operating problems could also be observed and analyzed through the RTD measurement, such as embankment of the equipment and the deficient regulation of the outflow, used to control the pulp level (Cw)

  6. Measuring and test equipment control through bar-code technology

    International Nuclear Information System (INIS)

    Crockett, J.D.; Carr, C.C.

    1993-01-01

    Over the past several years, the use, tracking, and documentation of measuring and test equipment (M ampersand TE) has become a major issue. New regulations are forcing companies to develop new policies for providing use history, traceability, and accountability of M ampersand TE. This paper discusses how the Fast Flux Test Facility (FFTF), operated by Westinghouse Hanford Company and located at the Hanford site in Rich- land, Washington, overcame these obstacles by using a computerized system exercising bar-code technology. A data base was developed to identify M ampersand TE containing 33 separate fields, such as manufacturer, model, range, bar-code number, and other pertinent information. A bar-code label was attached to each piece of M ampersand TE. A second data base was created to identify the employee using the M ampersand TE. The fields contained pertinent user information such as name, location, and payroll number. Each employee's payroll number was bar coded and attached to the back of their identification badge. A computer program was developed to automate certain tasks previously performed and tracked by hand. Bar-code technology was combined with this computer program to control the input and distribution of information, eliminate common mistakes, electronically store information, and reduce the time required to check out the M ampersand TE for use

  7. Investigation of Leveling Equipment for High Precision Measurements

    International Nuclear Information System (INIS)

    Gassner, G.

    2007-01-01

    At SLAC (Stanford Linear Accelerator Center) a fully automated vertical comparator for the calibration of digital levels and invar staffs was developed by the Metrology Department in cooperation with the Institute of Engineering Geodesy and Measurement Systems at the Graz University of Technology. This vertical comparator is the first in the US. With the vertical comparator it is possible to perform system calibration and CCD camera measurements of rods. System calibration uses the height readings of the digital level at different positions of the rod and compares them with the reference readings obtained by the interferometer. In the case of CCD camera measurements, the positions of the edges in the image is determined and again compared with the interferometer readings. This document gives an overview of the current set-up of the SLAC vertical comparator and experimental results of critical applications including measurements at the end sections of the rod, at critical sighting distances, with unfocused optics and under illumination with the digital levels in use at SLAC

  8. Fleet equipment performance measurement preventive maintenance model : final report.

    Science.gov (United States)

    2014-04-01

    The concept of preventive maintenance is very important in the effective management and deployment of : vehicle fleets. The Texas Department of Transportation (TxDOT) operates a large fleet of on-road and offroad : equipment. Newer engines and vehicl...

  9. Reliability of agriculture universal joint shafts based on temperature measuring in universal joint bearing assemblies

    Directory of Open Access Journals (Sweden)

    Аleksandar Asonja

    2015-03-01

    Full Text Available This paper presents a research into reliability calculations of agriculture double universal joint shafts based on temperature measuring in cardan-type universal joint bearing assemblies. Special laboratory equipment was developed for this research which is presented in the paper. The objective of this research was to test the real life span of universal joint shafts in the laboratory and in field, to obtain the results which can be used to improve the reliability of universal joint shafts. If the presented research were used along with maintenance measures recommended in the paper and with proper use, the level of reliability of the shafts would be 2.1 times higher. The presented results of the research showed that needle bearings, i.e. bearing assemblies of the joints, are the most critical elements on universal joint shafts and are possible causes of their lower reliability. The second universal joint is the part with the lowest reliability in the observed technical system.

  10. Results of evaluation of quality control measurement instrument of x-ray diagnostic equipment by non-invasive method

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Elbern, Alvin W.

    1996-01-01

    This work shows the results of the tests realized on Santa Rita Hospital (Porto Alegre), using a non invasive quality control measurement instrument, developed in this University for fast measurement of essential parameters of X-rays diagnostic equipment. In the tests we used a diagnostics Siemens X ray, model Heliofos 4E as our standard equipment. The linearity test of sensor probe and the exposure rate calibration was performed, with a Palmer Dosimeter. For the kVp and exposure time we used a RTI commercial instrument. (author)

  11. Power-Consumption Measurements for LTE User Equipment

    DEFF Research Database (Denmark)

    Lauridsen, Mads

    wireless communications test set and the Agilent N6705B DC power analyzer to establish a power consumption model for LTE user equipment (UE). The model is useful when you need to examine the UE battery life in system-level simulations. We will explain how the Agilent equipment can be used in manual tests......, but we do not discuss how to make automated tests (for example, using VEE software). In this application note, we analyze smartphones adhering to the 3GPP LTE standard [1]....

  12. An Equipment to Measure the Freezing Point of Soils under Higher Pressure

    Science.gov (United States)

    Wang, Dayan; Guan, Hui; Wen, Zhi; Ma, Wei

    2014-05-01

    control electron universal testing machines. All of above mentioned advantages of this equipment ensures one to catch up the moment soil turns from the thawed state into ice and enable one to determine the freezing point experimentally by recording the temperature-time history (cooling curve) at particular points within the sample used for analysis. Therefore, this equipment has excellent characteristics such as compact construction, convenient operation, high reliability and the measuring accuracy. The authors would like to thank the following agents for their financial supports: the National Natural Science Foundation (No.41071048),Hundred Talent Young Scientists program of the Chinese Academy of Sciences granted to Dr. Zhi Wen.

  13. Low-energy house in Sisimiut - Measurement equipment

    DEFF Research Database (Denmark)

    Andersen, Philip Hvidthøft Delff; Rode, Carsten; Madsen, Henrik

    on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented...

  14. Taking the Measure of the Universe

    Science.gov (United States)

    Hinshaw, Gary

    2009-01-01

    The cosmic microwave background (CMB) radiation is the oldest light in the universe - it is literally the remnant heat left over from the Big Bang. This fossil relic has survived largely intact and it provides us with a unique probe of conditions in the early universe, long before any stars or galaxies had formed. NASA has now flown two satellites devoted to studying the CMB: 'COBE' and 'WMAP'. In this lecture I will describe what we have learned from these missions including: evidence for the Big Bang itself; new measurements of the age, shape, and content of the universe; and new evidence that all structure in the universe emerged from microscopic quantum fluctuations in the primordial soup.

  15. Equipment for neutron measurements at VR-1 Sparrow training reactor

    International Nuclear Information System (INIS)

    Kolros, Antonin; Huml, Ondrej; Kos, Josef

    2008-01-01

    Full text: The VR-1 Sparrow training reactor is the experimental nuclear facility especially employed for education and teaching of students from different technical universities in the Czech Republic and other countries. Since 2005 the uniform all-purpose devices EMK310 have been used for measurement at reactor laboratory with different type of gas filled neutron detectors. The neutron detection system are employed for reactivity measurement, control rod calibration, critical experiment, study of delayed neutrons, study of nuclear reactor dynamics and study of detection systems dead time. The small dimension isotropic detectors are especially used for measurement of thermal neutron flux distribution inside the reactor core. The EMK-310 is a high performance, portable, three-channel fast amplitude analyzer designed for counting applications. It was developed for nuclear applications and made in close co-operation with firm TEMA Ltd. The precise rack eliminates electromagnetic disturbance and contains the control unit and four modules. The modules of high voltage supply and amplifier for gas filled detectors or scintillation probes are used in basic configuration. Software is tailored specifically to the reactor measurement and allows full online control. For applications involving the study of signals that may vary with the time, example study of delayed neutrons or nuclear reactor dynamics, the EMK-310 provides a Multichannel Scaling (MCS) acquisition mode. MCS dwell time can be set from 2 ms. Now, the new generation of digital multichannel analyzers DA310 is introduced. They have similarly attributes as EMK310 but the output information of unipolar signals from detector is more complete. The pipeline A/D converter with field programmable gate array (FPGA) is the hearth of the DA310 device. The resolution is 12 bits (4096 channels); the sample frequency is 80 MHz. The application for the neutron noise analysis is supposed. The correction method for non linearity

  16. Study on highly reliable digital communication technology of reactor nuclear measuring equipment

    International Nuclear Information System (INIS)

    Gu Pengfei; Huang Xiaojin

    2007-01-01

    To meet the need of highly reliable of reactor nuclear measuring equipment, in allusion to the idiographic request of nuclear measuring equipment, the actual technical development and the application in industrial field, we design a kind of redundancy communication net based on PROFIBUS, and a kind of communication interface module based on redundancy PROFIBUS communication, which link the nuclear measuring equipment and PROFIBUS communication net, and also lay a foundation for advanced research. (authors)

  17. Universal machine ''Shtrek'' and the tractor-lifter with pneumatic-equipment control. [Auxiliary multipurpose materials handling equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bal' bert, B M; Borumenskiy, V A; Lishenko, A P; Mitchenko, G A

    1982-01-01

    The machine ''Shtrek'' is described. It makes it possible to mechanize over 20 auxiliary operations: loading-unloading operations: extraction of old and deformed timbering; dissmantling of obstructions; erection of different types of timbering; making and restoring of drainage channels; laying and straightening of a drift and its leveling; assembly and disassembly of pipelines and mine equipment, etc. Depending on the type of operation, the machine has the corresponding suspended equipment. The elementary variant has a limited area of application at mines of the central region of the Dunbass. Currently a pneumatic variant of the machine ''Shtrek'' has been developed. The electric motor and the starter of the pumping equipment of the machine have been replaced by a pneumatic motor and pneumatically controlled valve KTM-50. In this case there was significant reduction in the weight of the pumping equipment and in its overall dimensions; the electric drive of the hydraulic distributors for controlling the mechanisms were replaced by simpler pneumatic ones; the logical circuit of the control system was constructed on the USEPPA elements. A specialized tractor-lifter designed for moving suspended loads is described for auxiliary operations in the near-face zone of the preparatory drifts. The machine also lifts and lowers the boom, rotates the boom by 270/sup 0/ and additionally lifts and lowers the weight-lifting hook.

  18. Equipment for the continuous measurement and identification of gamma radioactivity on aerosols

    Energy Technology Data Exchange (ETDEWEB)

    De Blas, Alfredo; Tapia, Carlos; Riego, Albert; Garcia, Roger; Dies, Javier; Diaz, Pedro [Nuclear Engineering Research Group, Departament of Physics and Nuclear Engineering, Technical University of Catalonia, Barcelona (Spain); Toral, Juan [Raditel Serveis. Tarragona (Spain); Batalla, Enric [Radiological Activities Corrdination Service - SCAR, Generalitat de Catalunya, Barcelona (Spain)

    2015-07-01

    Presentation the Equipment for the Continuous Measurement and Identification of Gamma Radioactivity on Aerosols developed by the Nuclear Engineering Research Group (NERG) from the Technical University of Catalonia (UPC) and the Raditel Company. The device is based on a fixed filter of glass fiber (100% borosilicate), this allows determine the concentration of activity of gamma emitters on aerosols in air. A specifically developed Spectrometry Analysis System has been developed. The analysis of the spectra allows the identification of the emitters and determine the concentration of activity. Nowadays four Stations with this equipment are operating on the Environmental Radiological Surveillance Network of the Catalonian Generalitat (Spain): two near the Asco and Vandellos Nuclear Power Plants in the province of Tarragona and one in the city of Barcelona. Soon a fourth monitor will be incorporated at Roses (province of Girona) and a fifth in Puigcerda (province of Barcelona). We present measurements and analysis of the evolution of the emitters identified on different stations of the Network. (authors)

  19. Construction and operation of an universal stopping equipment for the fragment separator of the GSI Darmstadt

    International Nuclear Information System (INIS)

    Weckenmann, J.; Hanelt, E.; Schmidt, K.H.

    1990-07-01

    The fragment separator is a magnetic spectrometer, in which an especially-shaped layer of matter is applied as ion-optical element. The energy loss occurring there is accompanied by a series of unwanted effects like nuclear reaction, elecromagnetic dissociation, energy and angle straggling. These effects reduce on the one hand the total resolution of the separator and on the other hand the number of the fragments, which reach the exit of the separator. In the present study it was stated that the influence of these effects exhibits in most of the cases only a weak dependence on the material of the stopper. The ideal stopper material has a mass number, which corresponds nearly to the mass number of the selected fragment. If only one single stopper material will be applied, a material with low mass number seems to be the best compromise. Therefore for the universal stopper equipment of the fragment separator aluminium was selected. A further object of this study was the profile of the stopper. In a symmetrically constructed magnet spectrometer as the fragment separator the highest resolution is then reached, when the required particles are stopped in the whole width of their momentum distribution by a constant factor. This requirement leads to a curved profile of the stopper. It was stated that the profile can be approached by a linear wedge shape without a disadvantageous change of the resolution of the separator. The technical realization of the universal stopping equipment for the fragment separator consists mainly of very accurately manufactured, shiftable, and rotatable wedge-shaped layers. By means of a step-motor guiding the profiles required for the isotope separation can thus be obtained in a wide range. (orig.) [de

  20. Peculiar velocity measurement in a clumpy universe

    Science.gov (United States)

    Habibi, Farhang; Baghram, Shant; Tavasoli, Saeed

    Aims: In this work, we address the issue of peculiar velocity measurement in a perturbed Friedmann universe using the deviations from measured luminosity distances of standard candles from background FRW universe. We want to show and quantify the statement that in intermediate redshifts (0.5 deviations from the background FRW model are not uniquely governed by peculiar velocities. Luminosity distances are modified by gravitational lensing. We also want to indicate the importance of relativistic calculations for peculiar velocity measurement at all redshifts. Methods: For this task, we discuss the relativistic correction on luminosity distance and redshift measurement and show the contribution of each of the corrections as lensing term, peculiar velocity of the source and Sachs-Wolfe effect. Then, we use the SNe Ia sample of Union 2, to investigate the relativistic effects, we consider. Results: We show that, using the conventional peculiar velocity method, that ignores the lensing effect, will result in an overestimate of the measured peculiar velocities at intermediate redshifts. Here, we quantify this effect. We show that at low redshifts the lensing effect is negligible compare to the effect of peculiar velocity. From the observational point of view, we show that the uncertainties on luminosity of the present SNe Ia data prevent us from precise measuring the peculiar velocities even at low redshifts (z < 0.2).

  1. CAPABILITY ASSESSMENT OF MEASURING EQUIPMENT USING STATISTIC METHOD

    Directory of Open Access Journals (Sweden)

    Pavel POLÁK

    2014-10-01

    Full Text Available Capability assessment of the measurement device is one of the methods of process quality control. Only in case the measurement device is capable, the capability of the measurement and consequently production process can be assessed. This paper deals with assessment of the capability of the measuring device using indices Cg and Cgk.

  2. Measurement of secondary emissions during laser cutting of steel equipments

    Energy Technology Data Exchange (ETDEWEB)

    Pilot, Guy [Institut de Radioprotection et de Surete Nucleaire, BP 68, 91192 Gif-sur-Yvette Cedex (France)], E-mail: guy.pilot@irsn.fr; Fauvel, Sylvain [Institut de Radioprotection et de Surete Nucleaire, BP 68, 91192 Gif-sur-Yvette Cedex (France); Gosse, Xavier [AREVA NC, Centre de Marcoule, 30200 Bagnols-sur-Ceze Cedex (France); Dinechin, Guillaume de [Commissariat a l' Energie Atomique, DEN/DM2S/SEMT, Saclay, Bat. 611, 91191 Gif-sur-Yvette Cedex (France); Vernhet, Didier [Commissariat a l' Energie Atomique, DEN/VRH/UMODD, Centre de Valrho, BP 17171, 20207 Bagnols-sur-Ceze Cedex (France)

    2008-08-15

    In order to dismantle some equipments of an obsolete reprocessing plant in Marcoule, studies were carried out by IRSN (Institut de Radioprotection et de Surete Nucleaire)/DSU/SERAC in cooperation with CEA (power laser group) on the laser cutting of steel structures, on the request of AREVA NC/Marcoule (UP1 dismantling project manager) and CEA/UMODD (UP1 dismantling owner). These studies were aimed at: {center_dot}quantifying and characterizing the secondary emissions produced by Nd-YAG laser cutting of Uranus 65 steel pieces and examining the influence of different parameters, {center_dot}qualifying a prefiltration technique and particularly an electrostatic precipitator, {center_dot}comparing the Nd-YAG laser used with other cutting tools previously studied especially on aerosol production and aerosol size distribution.

  3. Wireless Fluid-Level Measurement System Equips Boat Owners

    Science.gov (United States)

    2008-01-01

    While developing a measurement acquisition system to be used to retrofit aging aircraft with vehicle health monitoring capabilities, Langley Research Center developed an innovative wireless fluid-level measurement system. The NASA technology was of interest to Tidewater Sensors LLC, of Newport News, Virginia, because of its many advantages over conventional fuel management systems, including its ability to provide an accurate measurement of volume while a boat is experiencing any rocking motion due to waves or people moving about on the boat. These advantages led the company to license this novel fluid-level measurement system from NASA for marine applications.

  4. The optimization design of nuclear measurement teaching equipment

    International Nuclear Information System (INIS)

    Tang Rulong; Qiu Xiaoping

    2008-01-01

    So far domestic student-oriented experimental nuclear measuring instruments are used only to measure object density, thickness or material level, and in the choice of sources activity is mostly about 10 mCi. this design will proposed a optimization program dealing with domestic situation. It discussed the radioactive sources activity, the structural design of sealed sources, such as the choice of the tested material in order to get a program optimization. The program used 1 mCi activity radioactive sources 137 Cs to reduce the radiation dose, and the measurement function was improved. So that the apparatus can measure density, thickness nad material level. (authors)

  5. Survey on quality control measurements for nuclear medicine imaging equipment in Finland in 2006

    International Nuclear Information System (INIS)

    Korpela, Helinae; Niemelae, Jarkko

    2008-01-01

    Routine quality control (QC) is an essential requirement in nuclear medicine (NM) in order to ensure optimal functioning of equipment. To harmonise the routine QC of NM imaging equipment in Finnish hospital s (planar gamma cameras, SPECT, coincidence gamma cameras, PET), the Radiation and Nuclear Safety Authority (STUK) will publish guidelines on QC in collaboration with several hospital physicists. Recommendations will be provided on routine QC measurements and on the frequency of testing. It is also planned to provide recommendations for the acceptance criteria when assessing different performance parameters for NM imaging equipment. In order to determine what performance parameters of NM equipment are currently measured in hospitals, how frequently they are measured and what acceptance criteria are used, a survey was carried out on the QC of NM equipment in Finland during 2006. (author)

  6. Universality of measurements on quantum markets

    Science.gov (United States)

    Pakuła, Ireneusz; Piotrowski, Edward W.; Sładkowski, Jan

    2007-11-01

    Two of the authors have recently discussed financial markets operated by quantum computers-quantum market games. These “new markets” cannot by themselves create opportunity of making extraordinary profits or multiplying goods, but they may cause the dynamism of transaction which would result in more effective markets and capital flow into hands of the most efficient traders. Here we focus upon the problem of universality of measurement in quantum market games offering a possible method of implementation if the necessary technologies would be available. It can be also used to analyse material commitments that elude description in orthodox game-theoretic terms.

  7. Rock stress measurements. Preparatory stage of the equipment development project

    International Nuclear Information System (INIS)

    Mononen, S.; Hakala, M.; Mikkola, P.

    2002-01-01

    In recent years the rock stress measurement methods used in Finland have been overcoring and hydraulic fracturing. There have been mainly two companies involved in these measurements, namely Suomen Malmi Oy (Smoy) and SwedPower AB. Smoy has done measurements for mines and for rock engineering projects, whereas SwedPower AB has mainly been involved in nuclear waste disposal investigations and conducted hydraulic fracturing measurements in deep boreholes. Smoy together with its partners started in February 2001 a project named JTM, which was a preliminary stage for a future project, which aims to develop a device most suitable for rock stress measurements in Finland. The partners in the project were HUT Rock Engineering, Posiva Oy, Saanio and Riekkola Oy, Gridpoint Finland Oy and Geopros Oy. Tekes, the National Technology Agency, provided almost half of the project funding. In the management group of the project were Pekka Mikkola (chairman) and Tero Laurila from Smoy, Pekka Saerkkae and Sakari Mononen (full-time researcher) from HUT, Aimo Hautojaervi (Posiva Oy), Erik Johansson (Saanio and Riekkola Oy), Matti Hakala (Gridpoint Finland Oy) and Heikki Haemaelaeinen (Geopros Oy). The aim of the JTM-project was to find out the needs for the development of a device most suitable for rock stress measurements in Finnish mines and rock engineering projects. During the project work was done to find out the range of rock stress measurement devices available, to find out the needs for measurements, and to get acquainted to the measurements done in Scandinavia. Also a report of the most suitable methods for Finnish rock conditions was done based on literature and on interviews of rock stress experts. Based on all the information collected during the project a clear picture of the needs for rock stress measurements in Finland could be formed and a preliminary plan of a future project was done. The aim of the suggested project is to build a device based on hydraulic fracturing

  8. A Perceptual Measure of the Degree of Development of Proprietary Equipment.

    Science.gov (United States)

    Cua, Kristy O.; Junttila, Mikko A.; Schroeder, Roger G.

    2002-01-01

    Evaluated the psychometric properties of a perceptual measure of the extent to which manufacturing organizations develop proprietary equipment, the Proprietary Equipment Scale (developed by the World Class Manufacturing study). Analysis of data from 164 manufacturing plants in 5 countries indicates that although method effects are present, the…

  9. Development of digital power measuring and protecting equipment for SPRR-300 reactor

    International Nuclear Information System (INIS)

    Wang Xuejie; Li Xi'an; Zhu Shilei

    2005-01-01

    A measuring and protecting equipment of reactor power based on Single-Chip Microcomputer is introduced in this paper. The composition of hardware and the major control idea about the software for the equipment are presented. Digitizing the measuring data from nuclear instruments is precondition of reactor control and protection system which would be computerizing, and it is also an application of redundancy and variety of reactor protection system in nuclear measuring instruments. At last the working state is described. (authors)

  10. Equipment for thermal neutron flux measurements in reactor R2

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E; Nilsson, T; Claeson, S

    1960-04-15

    For most of the thermal neutron flux measurements in reactor R2 cobalt wires will be used. The loading and removal of these wires from the reactor core will be performed by means of a long aluminium tube and electromagnets. After irradiation the wires will be scanned in a semi-automatic device.

  11. Results form RESUME 95. Measurements with mobile equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lidstroem, K.; Ulvsand, T.; Aagren, G. [National Defence Research Establisment, Div. of Ionising Radiation and Fallout, Umeaa (Sweden)

    1997-12-31

    This paper presents the results obtained during the NKS, (EKO-3), Exercise Resume-95 by a group from the Division of Ionising Radiation and Fallout, FOA, Umeaa, Sweden. Field gamma measurements were performed in two areas with a HPGe-detector (p-type, 50% relative efficiency) mounted vertically 1 m above the ground or horizontally in a car. One of the areas was an airfield, Vesivehmaa, where 19 measurements were done. The calculated Cs-137 activity was 52.1 {+-} 4.5 kBq/m{sup 2} assuming a two slice distribution model with a homogenous density and activity distribution in each slice. The report contains also the results from a task which included the finding, classification and estimation of the activity of hidden sources within two 10{sup *} 10 m-areas. (au).

  12. Results form RESUME 95. Measurements with mobile equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lidstroem, K; Ulvsand, T; Aagren, G [National Defence Research Establisment, Div. of Ionising Radiation and Fallout, Umeaa (Sweden)

    1998-12-31

    This paper presents the results obtained during the NKS, (EKO-3), Exercise Resume-95 by a group from the Division of Ionising Radiation and Fallout, FOA, Umeaa, Sweden. Field gamma measurements were performed in two areas with a HPGe-detector (p-type, 50% relative efficiency) mounted vertically 1 m above the ground or horizontally in a car. One of the areas was an airfield, Vesivehmaa, where 19 measurements were done. The calculated Cs-137 activity was 52.1 {+-} 4.5 kBq/m{sup 2} assuming a two slice distribution model with a homogenous density and activity distribution in each slice. The report contains also the results from a task which included the finding, classification and estimation of the activity of hidden sources within two 10{sup *} 10 m-areas. (au).

  13. Painting recognition with smartphones equipped with inertial measurement unit

    Science.gov (United States)

    Masiero, Andrea; Guarnieri, Alberto; Pirotti, Francesco; Vettore, Antonio

    2015-06-01

    Recently, several works have been proposed in the literature to take advantage of the diffusion of smartphones to improve people experience during museum visits. The rationale is that of substituting traditional written/audio guides with interactive electronic guides usable on a mobile phone. Augmented reality systems are usually considered to make the use of such electronic guides more effective for the user. The main goal of such augmented reality system (i.e. providing the user with the information of his/her interest) is usually achieved by properly executing the following three tasks: recognizing the object of interest to the user, retrieving the most relevant information about it, properly presenting the retrieved information. This paper focuses on the first task: we consider the problem of painting recognition by means of measure- ments provided by a smartphone. We assume that the user acquires one image of the painting of interest with the standard camera of the device. This image is compared with a set of reference images of the museum objects in order to recognize the object of interest to the user. Since comparing images taken in different conditions can lead to unsatisfactory recognition results, the acquired image is typically properly transformed in order to improve the results of the recognition system: first, the system estimates the homography between properly matched features in the two images. Then, the user image is transformed accordingly to the estimated homography. Finally, it is compared with the reference one. This work proposes a novel method to exploit inertial measurement unit (IMU) measurements to improve the system performance, in particular in terms of computational load reduction: IMU measurements are exploited to reduce both the computational burden required to estimate the transformation to be applied to the user image, and the number of reference images to be compared with it.

  14. Design of measurement equipment for high power laser beam shapes

    DEFF Research Database (Denmark)

    Hansen, K. S.; Olsen, F. O.; Kristiansen, Morten

    2013-01-01

    To analyse advanced high power beam patterns, a method, which is capable of analysing the intensity distribution in 3D is needed. Further a measuring of scattered light in the same system is preferred. This requires a high signal to noise ratio. Such a system can be realised by a CCD-chip impleme...... by a commercial product has been done. The realised system might suffer from some thermal drift at high power; future work is to clarify this....

  15. Reviews Equipment: BioLite Camp Stove Game: Burnout Paradise Equipment: 850 Universal interface and Capstone software Equipment: xllogger Book: Science Magic Tricks and Puzzles Equipment: Spinthariscope Equipment: DC Power Supply HY5002 Web Watch

    Science.gov (United States)

    2013-05-01

    WE RECOMMEND BioLite CampStove Robust and multifaceted stove illuminates physics concepts 850 Universal interface and Capstone software Powerful data-acquisition system offers many options for student experiments and demonstrations xllogger Obtaining results is far from an uphill struggle with this easy-to-use datalogger Science Magic Tricks and Puzzles Small but perfectly formed and inexpensive book packed with 'magic-of-science' demonstrations Spinthariscope Kit for older students to have the memorable experience of 'seeing' radioactivity WORTH A LOOK DC Power Supply HY5002 Solid and effective, but noisy and lacks portability HANDLE WITH CARE Burnout Paradise Car computer game may be quick off the mark, but goes nowhere fast when it comes to lab use WEB WATCH 'Live' tube map and free apps would be a useful addition to school physics, but maths-questions website of no more use than a textbook

  16. Algorithms for diagnostics of the measuring channels and technological equipment at NPP with WWER-1000

    International Nuclear Information System (INIS)

    Vysotskij, V.G.

    1997-01-01

    An algorithm for diagnostics of the state of measuring channels of an information computer system with usage of analysis of statistical channel characteristics is presented. An algorithm for testing the generalized state of the NPP technological equipment is proposed

  17. International intercalibration and intercomparison programme for radon, thoron and daughters measuring equipment. Part. 1: Radon measurement

    International Nuclear Information System (INIS)

    Knutson, E.O.; Solomon, S.B.

    1986-01-01

    The International Intercalibration and Intercomparison Programme for Radon, Thoron and Daughters Monitoring Equipment, abbreviated IIIP, is a program organized jointly by Nuclear Energy Agency of the Organization for Economic Cooperation and Development and the Radiation Protection Research Programme of the Commission of European Communities. The broad purpose of the IIIP is to determine if the somewhat diverse calibration procedures used in different countries are equivalent. The general approach was to select four regional reference laboratories and entrust them with the details of project definition and execution. The four selected laboratories are: Australian Radiation Laboratory, US DOE Environmental Measurements Laboratory, UK National Radiation Protection Board, US DOI Bureau of Mines. The Organizing Committee that selected the four laboratories remained intact and served an oversight function in all work to date

  18. Measuring the productivity of university research reactors

    International Nuclear Information System (INIS)

    Voth, M.H.

    1989-01-01

    University Research Reactors (URRs) on 33 campuses in the United States provide valuable contributions to academic instruction and research programs. In most cases, there are no alternative diagnostic techniques to supplant the need for a reactor and associated facilities. Since URRs constitute a major financial commitment, it is important that they be operated in a productive manner. Productivity may be defined as the sum of new knowledge generated, existing knowledge transferred to others, and analytical services provided to assist in the generation of new knowledge; another definition of productivity is this sum expressed as a function of the cost incurred. In either case, a consistent measurement is difficult and more qualitative than quantitative. A uniform reporting system has been proposed that defines simplified categories through which meaningful comparisons can be performed

  19. Universal microcomputer ABM 80 for data processing and measurement devices control

    International Nuclear Information System (INIS)

    Jagiello, S.; Kozminski, A.; Plominski, M.; Rzymkowski, K.

    1983-01-01

    The main features of the universal microcomputer ABM-80 with microprocessor INTEL 8080 are described. ABM-80 works with the measurer AZAR and the register ERD-102 or with other equipment with similar input/output parameters. Monitor program is an integral part of the microcomputer. (author)

  20. Equipment for measuring pulsed supply of the 400 GeV CERN accelerator

    CERN Document Server

    Aubry, G; De Vries, J

    1977-01-01

    Describes the energy measuring equipment for metering the pulsed supply to the CERN proton synchrotron which is under design and development by Landis and Gyr in association with Electricity' de France. The design will take into account the shape of the load curve and the tariff structure of the supply company. It will include solid state metering, a mini-computer and telemetering equipment. (2 refs).

  1. Research on reliability measures of the main transformer and GIS equipment manufacturing process

    International Nuclear Information System (INIS)

    Wu Honglong

    2014-01-01

    Based on the accidents of the main transformer GIS equipment and the accidents of the high voltage switch equipment, combined with the main transformer switch equipment maintenance experience and electrical theory, the reliability measures of the main transformer GIS equipment during manufacturing stage are studied and improved. Six successful reliability measures are identified: 1) design properly and check the ability of transformer for anti short circuit; 2) choose mature and reliable main transformer HV bushing; 3) choose GIS switch operation mechanism of high quality and reliability; 4) ensure that the insulation margin through tests piece by piece on withstand voltage and partial discharge of the GIS equipment insulation; 5) take test measures such as GIS conductor, shell polishing witness process and full form lightning impulse, to find out and eliminate the defects of abnormal electric field distribution; 6) Anti VFTO design for the main transformer connected with GIS with the voltage of 500 kV should be considered, and its anti VFTO ability to meet the safe operation under VFTO requirements should be checked. This paper proposed 2 new measures: 1) the main transformer insulation material quality standard is determined not only by its high dielectric strength, but more importantly by the homogeneous dielectric electric strength. Insulating Materials with a high and also uniform dielectric strength should be chosen. 2) During the silver-coating stage of the GIS equipment conductor, QC group activities should be organized to ensure that the plating layer quality, and the current lap surface DC resistance measurements should be supervised and witnessed to ensure the quality of the conductor contact surface. These measures are verified in Fuqing project of GIS main transformer equipment manufacturing process, and their effectiveness is proven. (author)

  2. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  3. Study of multi-functional precision optical measuring system for large scale equipment

    Science.gov (United States)

    Jiang, Wei; Lao, Dabao; Zhou, Weihu; Zhang, Wenying; Jiang, Xingjian; Wang, Yongxi

    2017-10-01

    The effective application of high performance measurement technology can greatly improve the large-scale equipment manufacturing ability. Therefore, the geometric parameters measurement, such as size, attitude and position, requires the measurement system with high precision, multi-function, portability and other characteristics. However, the existing measuring instruments, such as laser tracker, total station, photogrammetry system, mostly has single function, station moving and other shortcomings. Laser tracker needs to work with cooperative target, but it can hardly meet the requirement of measurement in extreme environment. Total station is mainly used for outdoor surveying and mapping, it is hard to achieve the demand of accuracy in industrial measurement. Photogrammetry system can achieve a wide range of multi-point measurement, but the measuring range is limited and need to repeatedly move station. The paper presents a non-contact opto-electronic measuring instrument, not only it can work by scanning the measurement path but also measuring the cooperative target by tracking measurement. The system is based on some key technologies, such as absolute distance measurement, two-dimensional angle measurement, automatically target recognition and accurate aiming, precision control, assembly of complex mechanical system and multi-functional 3D visualization software. Among them, the absolute distance measurement module ensures measurement with high accuracy, and the twodimensional angle measuring module provides precision angle measurement. The system is suitable for the case of noncontact measurement of large-scale equipment, it can ensure the quality and performance of large-scale equipment throughout the process of manufacturing and improve the manufacturing ability of large-scale and high-end equipment.

  4. [Current state of measures to deal with natural disasters at public universities].

    Science.gov (United States)

    Hirouchi, Tomoko; Tanka, Mamoru; Shimada, Ikuko; Yoshimoto, Yoshinobu; Sato, Atsushi

    2012-03-01

    The responsibility of a university after a large-scale, natural disaster is to secure the safety of students' and local residents' lives. The present study investigated the current state of measures at public universities to deal with natural disasters in coordination with the local community. A survey was administered at 77 public universities in Japan from March 25 to May 10, 2011. The survey included questions on the existence of local disaster evacuation sites, a disaster manual, disaster equipment storage, emergency drinking water, and food storage. A total of 51% of universities had designated local evacuation sites. Based on responses for the remaining questions, universities with and without the designated disaster response solutions accounted for 42% and 57%, respectively, for disaster manuals; 55% and 33%, respectively, for disaster equipment; 32% and 13%, respectively, for disaster drinking water storage; and 26% and 7%, respectively, for emergency food storage. A majority of public universities have not created disaster manuals, regardless of whether they have a local evacuation site. The survey results also indicated that most universities have no storage of disaster equipment or emergency supplies.

  5. Instruction manual for the use of CSIR triaxial rock stress measuring equipment

    CSIR Research Space (South Africa)

    Coetzer, SJ

    1998-08-01

    Full Text Available This is an updated version of CSIR Report no ME 1763 entitled "Instruction manual for the use for the CSIR triaxial rock stress measuring equipment" by F A Vreede. The manual contains a detailed description of CSIR Triaxial rock stress measuring...

  6. The equipment for low radioactivity measurements in industrial and field conditions

    International Nuclear Information System (INIS)

    Malik, R.; Owczarczyk, A.; Szpilowski, S.; Zenczykiewicz, Z.

    1992-01-01

    The equipment for low radioactivity measurements in industrial and field conditions has been worked out. Three scintillation detectors applied work in coincidence system. Their scintillation crystals are divided one to another by lead shieldings. All measuring system is situated in a lead container with lead cover. The measuring vessel fills practically all free volume of the lead container. Their shape ensures the best possible measurement geometry. (author). 3 figs

  7. CFD validation by measurement of specialized ventilation equipments on duct tract

    Directory of Open Access Journals (Sweden)

    Sehnalek Stanislav

    2017-01-01

    Full Text Available This article describes measurement of HVAC distribution box on air duct track in Laboratory of Environmental Engineering (LEE. Firstly, the paper describes the LEE and then measurement apparatus with description of calculation methods. Then follows specification of sample with introduction to newly developed equipment for positioning of the anemometer. The evaluation of results of measurements with CFD comparison follows. The article is concluded with discussion over measured data with an outline for further research.

  8. Measuring our Universe from Galaxy Redshift Surveys.

    Science.gov (United States)

    Lahav, Ofer; Suto, Yasushi

    2004-01-01

    Galaxy redshift surveys have achieved significant progress over the last couple of decades. Those surveys tell us in the most straightforward way what our local Universe looks like. While the galaxy distribution traces the bright side of the Universe, detailed quantitative analyses of the data have even revealed the dark side of the Universe dominated by non-baryonic dark matter as well as more mysterious dark energy (or Einstein's cosmological constant). We describe several methodologies of using galaxy redshift surveys as cosmological probes, and then summarize the recent results from the existing surveys. Finally we present our views on the future of redshift surveys in the era of precision cosmology.

  9. Measurement of the electrostatic charge in airborne particles: I - development of the equipment and preliminary results

    Directory of Open Access Journals (Sweden)

    Marra Jr. W.D.

    2000-01-01

    Full Text Available The design and construction of a equipment capable of measuring the electrostatic charges in aerosols, named the electrostatic charge classifier, were carried out. They were based on the concept of particle electromobility and the charge classifier was intended to classify the nature and the distribution of electrostatic charges as a function of particle size. The resulting piece of equipment is easy to dismount, which facilitates its cleaning and transport, and easy to operate. Early results indicate that the values of electrostatic charge measured on test particles are inside the range reported in the literature, indicating the adequacy of the technique utilized.

  10. Design, manufacture and installation of measuring and control equipments for the advanced thermal prototype reactor 'Fugen'

    International Nuclear Information System (INIS)

    Hirota, Shigeo; Kawabata, Yoshinori

    1979-01-01

    The advanced thermal prototype reactor ''Fugen'' attained the criticality on March 20, 1978, and 100% output operation on November 13, 1978. On March 20, 1979, it passed the final inspection, and since then, it has continued the smooth operation up to now. The measuring and control equipments are provided for grasping the operational conditions of the plant and operating it safely and efficiently. At the time of designing, manufacturing and installing the measuring and control equipments for Fugen, it was required to clarify the requirements of the plant design, to secure the sufficient functions, and to improve the operational process, maintainability and the reliability and accuracy of the equipments. Many design guidelines and criteria were decided in order to coordinate the conditions among five manufacturers and give the unified state as one plant. The outline of the instrumentations for neutrons, radiation monitoring and process data, the control systems for reactivity, reactor output, pressure and water supply, the safety protection system, and the process computer are described. Finally, the installations and tests of the measuring and control equipments are explained. The aseismatic capability of the equipments was confirmed. (Kako, I.)

  11. Measuring our Universe from Galaxy Redshift Surveys

    Directory of Open Access Journals (Sweden)

    Lahav Ofer

    2004-07-01

    Full Text Available Galaxy redshift surveys have achieved significant progress over the last couple of decades. Those surveys tell us in the most straightforward way what our local Universe looks like. While the galaxy distribution traces the bright side of the Universe, detailed quantitative analyses of the data have even revealed the dark side of the Universe dominated by non-baryonic dark matter as well as more mysterious dark energy (or Einstein's cosmological constant. We describe several methodologies of using galaxy redshift surveys as cosmological probes, and then summarize the recent results from the existing surveys. Finally we present our views on the future of redshift surveys in the era of precision cosmology.

  12. Dose profile measurement in computerized axial tomography equipment using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin V, J.C.; Falcony, C.; Azorin N, J.

    2000-01-01

    In this work are presented the results about measuring the radiation dose profile in two equipment of computerized axial tomography (Tac). Thermoluminescent dosemeters (Dtl) of LiF, Mg, Cu, P + Ptfe in form of disks were used which were developed and made in Mexico. The results showed that Dtl are appropriated for these type of studies. (Author)

  13. Benchmarking of Governmental Support Measures for University-Industry Cooperation

    Directory of Open Access Journals (Sweden)

    Kärt Rõigas

    2013-01-01

    Full Text Available This paper aims to benchmark Estonian governmental support measures targeted toward enhancing university-industry collaboration to European best practice and make suggestions for the development of these measures. The intensity and scope of university-industry cooperation support measures varies heavily in Europe. The survey of European University-Business Cooperation, Pro Inno Europe and Erawatch database of policy measures, and Community Innovation Survey reveal that Finnish, German and Austrian support systems are best balanced and provide good university-industry cooperation intensity. The cooperation measures in Estonia are weak and improvement should be made by increasing the Estonian governmental funding, mandatory cooperation in support measures, networking and applied research in universities, on-going application possibilities, reducing the bureaucracy, and improving the timing of measures.

  14. Attribute measurement equipment for the verification of plutonium in classified forms for the Trilateral Initiative

    International Nuclear Information System (INIS)

    Langner, D.G.; Hsue, S.-T.; Macarthur, D.W.

    2001-01-01

    Full text: A team of technical experts from the Russian Federation, the International Atomic Energy Agency (IAEA) and the United States have been working for almost five years on the development of a tool kit of instruments that could be used to verify plutonium-bearing items that have classified characteristics in nuclear weapons states. This suite of instruments is similar in many ways to standard safeguards equipment and includes high-resolution gamma-ray spectrometers, neutron multiplicity counters, gross neutron counters and gross gamma-ray detectors. In safeguards applications, this equipment is known to be robust, and authentication methods are well understood. This equipment is very intrusive, however, and a traditional safeguards application of such equipment for verification of materials with classified characteristics would reveal classified information to the inspector, Several enabling technologies have been or are being developed to facilitate the use of these trusted, but intrusive technologies. In this paper, these technologies will be described. One of the new technologies is called an Attribute Verification System with an Information Barrier Utilizing Neutron Multiplicity Counting and High-Resolution Gamma-Ray Spectrometry' or AVNG. The radiation measurement equipment, comprising a neutron multiplicity counter and high-resolution gamma-ray spectrometer, is standard safeguards-type equipment with information security features added. The information barrier is a combination of technical and procedural methods that protect classified information while allowing the inspector to have confidence that the measurement equipment is providing authentic results. The approach is to reduce the radiation data collected by the measurement equipment to a simple 'yes/no' result regarding attributes of the plutonium-bearing item. The 'yes/no' result is unclassified by design so that it can be shared with an inspector. The attributes that the Trilateral Initiative

  15. Equipment for measuring torque and diagnostic data on control rod drive of nuclear reactor

    International Nuclear Information System (INIS)

    Simka, K.; Sneberger, J.; Tater, V.

    1991-01-01

    The equipment comprises an electric drive, a measuring unit and a device securing the movable parts of the drive. It can be used to measure the torque and diagnostic data of the control facility drive with the desired accuracy without having to dismantle the facility during decoupling or coupling the control component to the drive, during programming the movable parts in the transporting position. (Z.S.). 1 fig

  16. Measuring recent research performance for Chinese universities using bibliometric methods

    KAUST Repository

    Zhu, Jia

    2014-07-29

    This paper focuses on measuring the academic research performance of Chinese universities by using Scopus database from 2007 to 2010. We have provided meaningful indicators to measure the research performance of Chinese universities as compared to world class universities of the US and the European region. Using these indicators, we first measure the quantity and quality of the research outcomes of the universities and then examine the internationalization of research by using international collaborations, international citations and international impact metrics. Using all of this data, we finally present an overall score called research performance point to measure the comprehensive research strength of the universities for the selected subject categories. The comparison identifies the gap between Chinese universities and top-tier universities from selected regions across various subject areas. We find that Chinese universities are doing well in terms of publication volume but receive less citations from their published work. We also find that the Chinese universities have relative low percentage of publications at high impact venues, which may be the reason that they are not receiving more citations. Therefore, a careful selection of publication venues may help the Chinese universities to compete with world class universities and increase their research internationalization. © 2014 Akadémiai Kiadó, Budapest, Hungary.

  17. Primary measuring of equipment factor of 222Rn/220Rn indoor

    International Nuclear Information System (INIS)

    Liu Yanyang; Liu Fudong; Wang Chunhong; Sheng Mingwei

    2010-01-01

    The activity concentration of 222 Rn, 220 Rn and their progenies of certain working places and dwellings in Baotou city were measured simultaneously. Based on these results, the equipment factor of 222 Rn is 0.35 for working places and 0.43 for dwellings, while equipment factor of 220 Rn measured at 20 cm distance from wall is 0.030 for both working places and dwellings. Preliminary results show that the temporal change of 220 Rn equilibrium equivalent concentration is same as 222 Rn which is high in midnight and low in afternoon,and significant difference between instant and accumulated measure result of 222 Rn, 220 Rn activity concentration is found, with the factor of 2.1 and 1.7. (authors)

  18. Sensors for Metering Heat Flux Area Density and Metrological Equipment for the Heat Flux Density Measurement

    Science.gov (United States)

    Doronin, D. O.

    2018-04-01

    The demand in measuring and studies of heat conduction of various media is very urgent now. This article considers the problem of heat conduction monitoring and measurement in various media and materials in any industries and branches of science as well as metrological support of the heat flux measurement equipment. The main study objects are both the sensors manufactured and facilities onto which these sensors will be installed: different cladding structures of the buildings, awnings, rocket fairings, boiler units, internal combustion engines. The Company develops and manufactures different types of heat flux sensors: thermocouple, thin-film, heterogeneous gradient as well as metrological equipment for the gauging calibration of the heat flux density measurement. The calibration shall be performed using both referencing method in the unit and by fixed setting of the heat flux in the unit. To manufacture heterogeneous heat flux gradient sensors (HHFGS) the Company developed and designed a number of units: diffusion welding unit, HHFGS cutting unit. Rather good quality HHFGS prototypes were obtained. At this stage the factory tests on the equipment for the heat flux density measurement equipment are planned. A high-sensitivity heat flux sensor was produced, now it is tested at the Construction Physics Research Institute (Moscow). It became possible to create thin-film heat flux sensors with the sensitivity not worse than that of the sensors manufactured by Captec Company (France). The Company has sufficient premises to supply the market with a wide range of sensors, to master new sensor manufacture technologies which will enable their application range.

  19. Emergency preparedness in Finland: improvement of the measurement equipment used in the assessment of internal doses

    Energy Technology Data Exchange (ETDEWEB)

    Muikku, M.; Rahola, T. [STUK - Radiation and nuclear safety authority, Helsinki (Finland)

    2006-07-01

    The need for assessing internal radiation doses in emergency situations is evident. Internal exposure can be assessed using direct measurement results or by using information on activity concentrations in inhaled air and in foodstuffs combined with inhalation and consumption data. As a part of the continuous improving of emergency preparedness in Finland, S.T.U.K. - Radiation and Nuclear Safety Authority has obtained 35 monitors for thyroid measurements in field conditions and initiated a project to revise the radiation measurement equipment in local food and environmental laboratories. (authors)

  20. Design of channel experiment equipment for measuring coolant velocity of innovative research reactor

    International Nuclear Information System (INIS)

    Muhammad Subekti; Endiah Puji Hastuti; Dedi Heriyanto

    2014-01-01

    The design of innovative high flux research reactor (RRI) requires high power so that the capability core cooling requires to be improved by designing the faster core coolant velocity near to the critical velocity limit. Hence, the critical coolant velocity as the one of the important parameter of the reactor safety shall be measured by special equipment to the velocity limit that may induce fuel element degradation. The research aims is to calculate theoretically the critical coolant velocity and to design the special experiment equipment namely EXNal for measuring the critical coolant velocity in fuel element subchannel of the RRI. EXNal design considers the critical velocity calculation result of 20.52 m/s to determine the variation of flow rate of 4.5-29.2 m 3 /h, in which the experiment could simulate the 1-4X standard coolant velocity of RSG-GAS as well as destructive test of RRI's fuel plate. (author)

  1. In situ measurement of dynamic characteristics of atomic power plant equipment

    International Nuclear Information System (INIS)

    Arya, A.S.; Gupta, S.P.; Shrivastava, S.K.

    1977-01-01

    For the realistic assessment of stiffness and damping, full scale free vibration tests have been carried out on various pieces of equipment located in plant buildings both during the construction stage and after they are erected. Initial displacement or initial velocity was used to excite the free vibrations. Initial displacement was imparted by means of steel rope pulled with chain pulley block. The sudden release was achieved by means of a clutch system. Acceleration transducer with amplifier and ink writting oscillograph was used for recording the vibrations. Frequency and damping was evaluated from the acceleration records. Observed values for some equipment are given. For some equipment, it has been possible to obtain the values with and without pipe connections. The frequency of L.P. Heater in longitudinal and transverse directions without pipe connection were 17.86 and 10.04 Hz but with pipe connections the values increased to 26.74 and 17.85 Hz. Similarly there has been increase in the damping values too. Thus both the frequency and damping increases substantially with the addition of pipe connections. Moreover, their values are quite different in the two principal directions, pointing out to the importance of in situ measurements on prototype equipment

  2. The Present Status of the Half-Life Measuring Equipment and Technique at Studsvik

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G

    1967-10-15

    The present article presents the equipment and technique used at Studsvik for measuring half-lives of nuclear excited states using the delayed coincidence method. The experimental set up includes an electron-electron coincidence spectrometer and a fast pneumatic rabbit system attached to the high flux reactor R2 at Studsvik. Special efforts have been made to adapt the system for work with short lived radioactive isotopes with decay times of the order of seconds.

  3. Beam transmission in MP equipment. New measurements. Main effects and application to VIVITRON

    International Nuclear Information System (INIS)

    Haas, F.; Muller, C.; Nadji, A.; Rebmeister, R.

    1989-01-01

    The MP equipment is presented and the vacuum values at different measuring points are indicated. The low energy transmission stage (foil and gas strippers) high energy stage (5, 10, and 15 micro-g/cm 2 foils and gas stripper) are described, as well as the global system. For the Vivitron, in order to reach equilibrium thickness, pression in the stripping channel should be higher than that in the MP channel, and pump power should be planned accordingly [fr

  4. Variability at Multiple Scales: Using an Array of Current and Pressure Sensor Equipped Inverted Echo Sounders to Measure the Ocean

    Science.gov (United States)

    2016-11-29

    of Current- and Pressure - Sensor Equipped Inverted Echo Sounders to Measure the Ocean 5b. GRANT NUMBER NOOO 14-15-1-2857 5c. PROGRAM ELEMENT NUMBER...inverted echo sounders (lESs) equipped with pressure and current sensors (CPIESs). CPIESs are moored instruments that measure the round-trip acoustic...at a range of spatial and temporal scales. The goals of this project were to enhance the pool of pressure - sensor equipped lESs available at the

  5. Measurement problem in Program Universe. Revision

    International Nuclear Information System (INIS)

    Noyes, H.P.; Gefwert, C.; Manthey, M.J.

    1985-07-01

    The ''measurement problem'' of contemporary physics is in our view an artifact of its philosophical and mathematical underpinnings. We describe a new philosophical view of theory formation, rooted in Wittgenstein, and Bishop's and Martin-Loef's constructivity, which obviates such discussions. We present an unfinished, but very encouraging, theory which is compatible with this philosophical framework. The theory is based on the concepts of counting and combinatorics in the framework provided by the combinatorial hierarchy, a unique hierarchy of bit strings which interact by an operation called discrimination. Measurement criteria incorporate c, h-bar and m/sub p/ or (not ''and'') G. The resulting theory is discrete throughout, contains no infinities, and, as far as we have developed it, is in agreement with quantum mechanical and cosmological fact. 15 refs

  6. Measurement problem in Program Universe. Revision

    Science.gov (United States)

    Noyes, H. P.; Gefwert, C.; Manthey, M. J.

    1985-07-01

    The measurement problem of contemporary physics is in our view an artifact of its philosophical and mathematical underpinnings. We describe a new philosophical view of theory formation, rooted in Wittgenstein, and Bishop's and Martin-Loef's constructivity, which obviates such discussions. We present an unfinished, but very encouraging, theory which is compatible with this philosophical framework. The theory is based on the concepts of counting and combinatorics in the framework provided by the combinatorial hierarchy, a unique hierarchy of bit strings which interact by an operation called discrimination. Measurement criteria incorporate c, h-bar and m/sub p/ or (not and) G. The resulting theory is discrete throughout, contains no infinities, and, as far as we have developed it, is in agreement with quantum mechanical and cosmological fact.

  7. THE PROGRAM-TARGET PLANNING AND MANAGEMENT OF DEVELOPMENT OF MEASURING EQUIPMENT PARK

    Directory of Open Access Journals (Sweden)

    Marichev Pavel Aleksandrovich

    2018-02-01

    Full Text Available Subject: study of the Park of Measuring Equipment (PME that includes hundreds of thousands of standard samples, measuring instruments, control and measuring devices and other measuring mechanisms with different areas of application, levels of reliability, service life, levels of technical perfection and levels of technical condition. Research objectives: 1. Development of a complex of mathematical models to simulate the processes of development of PME, control indicators of PME performance as a whole, purposefully control the stages of life cycle of measuring equipment samples. 2. Development of the method which, with a sufficient degree of validity and objectivity, would solve the tasks of management of procurement and repairs both in preparation of proposals for preliminary long-term plan documents (LTPD and to ensure control over the implementation of adopted plans. Thus, the method being developed should be fairly simple to use, easily adjustable for solving problems of different dimensions, suitable for solving the optimal control problem for PME as a whole, for a part of PME, and also suitable for solving a generalized problem for certain “aggregated objects” such as the Metrology Centers. Materials and methods: the methods of mathematical simulation, methods of comparative analysis, simplex method for solving linear programming problem, methods of program-target planning were used. Results: an approach to the solution of problems of program-target planning based on solving a series of linear programming problems has been developed. The results have been presented of using the approach both for formulation of proposals into the preliminary LTPD and also for introducing revisions (amendments to annual plans, which are implemented in the framework of the state defense order. Conclusions: the described method and algorithms constitute an effective tool for solving practical problems of target-oriented management of PME performance

  8. REVIEW OF EQUIPMENT USED IN RUSSIAN PRACTICE FOR ACCOUNTING MEASUREMENTS OF NUCLEAR MATERIALS

    International Nuclear Information System (INIS)

    NEYMOTIN, L.

    1999-01-01

    The objective of this work was to analyze instrumentation and methodologies used at Russian nuclear facilities for measurement of item nuclear materials, materials in bulk form, and waste streams; specify possibilities for the application of accounting measurements; and develop recommendations for improvement. The major steps and results: Representative conversion, enrichment (gas centrifuge), fuel fabrication, spent fuel reprocessing, and chemical-metallurgical production facilities in Russia were selected; Full lists of nuclear materials were prepared; Information about measurement methods and instrumentation for each type of nuclear material were gathered; and Recommendations on methodological and instrumentation support of accounting measurements for all types of materials were formulated. The analysis showed that the existing measurement methods and instrumentation serve mostly to support the technological process control and nuclear and radiation safety control. Requirements for these applications are lower than requirements for MC and A applications. To improve the state of MC and A at Russian nuclear facilities, significant changes in instrumentation support will be required, specifically in weighing equipment, volume measurements, and destructive and non-destructive analysis equipment, along with certified reference materials

  9. Aims and Formats of performance measurement at Danish Universities

    DEFF Research Database (Denmark)

    Raffnsøe-Møller, Morten

    2011-01-01

    Abstract This article traces the aims and formats of performance measurement of Danish Universities as they originate from the Ministry of Finance’s plan for governance of the public sector. The article further show that the fierce conflicts between central administration and the universities over...... and intelligent regimes – is used to propose a way out of the current governance impasse at the universities....

  10. A production of non-strain spacing of lattice planes measurement equipment and a measurement of general structure material

    International Nuclear Information System (INIS)

    Minakawa, Nobuaki; Moriai, Atsushi; Morii, Yukio

    2001-01-01

    It is necessary to determine Δd/d in the internal stress measurement by the neutron diffraction method. Therefore, in case the non-strain spacing of lattice planes d 0 (hkl) is measured using bulk material, even though it does and attaches in a sample table length or every width and it is performing the diffraction measurement, it is difficult to determine for a true non-strain spacing of lattice planes by a processing strain, the grain-orientation, etc. It is available for the infinite thing spacing of lattice planes near non-strain condition to be measured by doing random rotation for bulk material in a beam center, and measuring an average spacing of lattice planes. Practical non-strain spacing of lattice planes measurement equipment was made, and the measurement was performed about much structure material. (author)

  11. Contractors Road Heavy Equipment Area SWMU 055 Corrective Measures Implementation Progress Report

    Science.gov (United States)

    Dorman, Lane

    2015-01-01

    This Corrective Measures Implementation (CMI) Progress Report, Revision 1, for Contractor's Road Heavy Equipment (CRHE) Area Solid Waste Management Unit (SWMU) Number 055 was prepared by Geosyntec Consultants (Geosyntec) for the National Aeronautics and Space Administration (NASA) under contract number NNK09CA02B, Delivery Order NNK09CA62D and Project Number PCN ENV-2324. This CMI Progress Report documents: (i) activities conducted as part of supplemental assessment activities completed from June 2009 through November 2014; (ii) Engineering Evaluation (EE) Advanced Data Packages (ADPs); and (iii) recommendations for future activities related to corrective measures at the Site.

  12. University Performance Evaluations: What Are We Really Measuring?

    Science.gov (United States)

    Bedggood, Rowan E.; Donovan, Jerome D.

    2012-01-01

    Surveying students to garner feedback on teaching and subject quality is a common occurrence in many universities globally. Despite the criticisms surrounding whether measures associated with these surveys are indeed valid, university managers continue to utilise them in key decision making. These surveys mirror business practices where measuring…

  13. Measuring University Students' Approaches to Learning Statistics: An Invariance Study

    Science.gov (United States)

    Chiesi, Francesca; Primi, Caterina; Bilgin, Ayse Aysin; Lopez, Maria Virginia; del Carmen Fabrizio, Maria; Gozlu, Sitki; Tuan, Nguyen Minh

    2016-01-01

    The aim of the current study was to provide evidence that an abbreviated version of the Approaches and Study Skills Inventory for Students (ASSIST) was invariant across different languages and educational contexts in measuring university students' learning approaches to statistics. Data were collected on samples of university students attending…

  14. [Suicide Prevention and Mental Health Measures for Japanese University Students].

    Science.gov (United States)

    Ohnishi, Masaru; Koyama, Shihomi; Senoo, Akiko; Kawahara, Hiroko; Shimizu, Yukito

    2016-01-01

    According to the nationwide survey of the National University students in Japan, the annual suicide rate in 2012 was 15.7 per 100,000 undergraduate students. In many universities, suicide prevention is an important issue regarding mental health measures, and each university is actively examining this. The current situation concerning measures for suicide prevention in the Japanese National Universities was investigated in 2009. In 2010, the "college student's suicide prevention measures guideline, 2010" was established based on the results of this investigation. This guideline refers to the basic philosophy of suicide prevention in Chapter 1, risk factors for suicide in Chapter 2, and systems and activities for suicide prevention in Chapter 3. The Health Service Center, Okayama University plays central roles in mental health and suicide prevention measures on the Medical Campus. The primary prevention includes a mini-lecture on mental health, classes on mental health, and periodic workshops and lectures for freshmen. The secondary prevention includes interviews with students with mental health disorders by a psychiatrist during periodic health check-ups and introducing them to a hospital outside the university. The tertiary prevention includes support for students taking a leave of absence to return to school, periodic consultation with such students with mental disorders, and postvention following a suicide. We believe that for mental health measures on the university campus, it is important to efficiently make use of limited resources, and that these efforts will eventually lead to suicide prevention.

  15. Measurement of fat in the ovine milk: comparative study of the results acquired by official methodology and by electr onic equipments

    Directory of Open Access Journals (Sweden)

    Luiz Gustavo de Pellegrini

    2016-06-01

    Full Text Available The aim of this work was to perform a comparative study between the official method recommended by Brazilian laws and the electronic equipment of photometric measurement and ultrasound spectroscopy equipment for the quantification of total lipids of the ovine milk in order to check which equipment establishes the lipids level better. The experiment took place at Technology of Food Department in Santa Maria Federal University together with School Plant of Dairy products and Ovine culture Section of Zoo Technical Department. It was used twelve sheeps half Lacaune Lait blood, milked individually from the first to the tenth week of lactation. The milking was performed manually and the analyses took place after the refrigeration of the samples. Before executing the analyses, the samples were homogenized and soon after evaluated in terms of fat amount by three distinct methodologies: official Brazilian methodology through Gerber’s butyrometer (GB, electronic equipment of photometric measurement Milko-Tester® (MT and ultrasound spectroscopic equipment Lactoscan 90® (LS, which all analyses were performed in triple. The reproducibility of LS equipment was 100% for the analyzed samples, while MT equipment showed variability in most of the analyzed samples obtaining reproducibility of the results in just 22,5% of the samples. For the others samples the latter equipment obtained 50% of overrated values and 27,5% underrated values. Therefore, the results of this study let us to settle that the analysis of ovine Milk by ultrasound spectroscopy is efficient for the fat parameter when compared to the official Brazilian methodology.

  16. Measuring spin of black holes in the universe

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Measuring spin of black holes in the universe. Department of Physics Indian Institute of Science Bangalore. Notes: 74th Annual Meeting of Indian Academy of Science.

  17. Acoustic Measurements in Opera Houses: Comparison Between Different Techniques and Equipment

    Science.gov (United States)

    FAUSTI, P.; FARINA, A.

    2000-04-01

    In room acoustics, many objective parameters to quantify subjective impressions have been introduced. These quantities can be measured by using a wide variety of powerful tools and equipment. The results can be influenced by the measurement techniques and instruments used. Furthermore, the results also depend on the measurement positions and on the condition of the hall (full, empty, etc.). The aim of this work is to define a tightly standardized measurement procedure for the collection of a complete objective description of an opera house's acoustics. In this paper some of the results obtained by the authors after measurements made in three different halls are presented. Comparisons were made both between different hardware and software tools (real-time analyzer, DAT, PC-board, source, microphones, post-processing software) and between different measurement methods (interrupted stationary noise, true-impulse, pseudo-random white noise with impulse-response doconvolution, sine sweep) as well as between different positions in the halls, with and without the presence of musicians and audience. The results have shown that the differences obtained when using different measurement techniques and equipment are not of significant importance. The only effective differences were found regarding the recording techniques, as the monaural measurements give appreciably different results from the average of left and right channel of binaural measurements. Slightly different results were alsofound between true impulsive sources (pistol shots, balloons) and omni-directional (dodecahedral) loudspeakers. Attention must be paid to the signal-to-noise ratio, as this can influence the correct calculation of some acoustical parameters. Some differences, not as great as expected, were found in the results with and without the musicians in the orchestra shell and with and without the audience in the hall. This is probably due to the high sound absorption that is typical in Italian opera

  18. Equipping Liberal Arts Students with Skills in Data Analytics: Drake University Partners with Regional Businesses to Offer New Programs in a Rapidly Growing Field. A BHEF Case Study

    Science.gov (United States)

    Business-Higher Education Forum, 2016

    2016-01-01

    This case study examines how Business-Higher Education Forum (BHEF) member Drake University, a private university with a strong liberal arts tradition, is equipping its students to become data-enabled professionals. Through the collaboration of its business and higher education members, BHEF launched the National Higher Education and Workforce…

  19. Applying DEA sensitivity analysis to efficiency measurement of Vietnamese universities

    Directory of Open Access Journals (Sweden)

    Thi Thanh Huyen Nguyen

    2015-11-01

    Full Text Available The primary purpose of this study is to measure the technical efficiency of 30 doctorate-granting universities, the universities or the higher education institutes with PhD training programs, in Vietnam, applying the sensitivity analysis of data envelopment analysis (DEA. The study uses eight sets of input-output specifications using the replacement as well as aggregation/disaggregation of variables. The measurement results allow us to examine the sensitivity of the efficiency of these universities with the sets of variables. The findings also show the impact of variables on their efficiency and its “sustainability”.

  20. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University -- Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  1. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  2. Lessons Learnt and Mitigation Measures for the CERN LHC Equipment with RF fingers

    CERN Document Server

    Métral, E; Assmann, R W; Baglin, V; Barnes, M J; Berrig, O E; Bertarelli, A; Bregliozzi, G; Calatroni, S; Carra, F; Caspers, F; Day, H A; Ferro-Luzzi, M; Gallilee, M A; Garion, C; Garlasche, M; Grudiev, A; Jimenez, J M; Jones, R; Kononenko, O; Losito, R; Nougaret, J L; Parma, V; Redaelli, S; Salvant, B; Strubin, P; Veness, R; Vollinger, C; Weterings, W

    2013-01-01

    Beam-induced RF heating has been observed in several LHC components when the bunch/beam intensity was increased and/or the bunch length reduced. In particular eight bellows, out of the ten double-bellow modules present in the machine in 2011, were found with the spring, which should keep the RF fingers in good electrical contact with the central insert, broken. Following these observations, the designs of all the components of the LHC equipped with RF fingers have been reviewed. The lessons learnt and mitigation measures are presented in this paper.

  3. High performance gamma measurements of equipment retrieved from Hanford high-level nuclear waste tanks

    Energy Technology Data Exchange (ETDEWEB)

    Troyer, G.L.

    1997-03-17

    The cleanup of high level defense nuclear waste at the Hanford site presents several progressive challenges. Among these is the removal and disposal of various components from buried active waste tanks to allow new equipment insertion or hazards mitigation. A unique automated retrieval system at the tank provides for retrieval, high pressure washing, inventory measurement, and containment for disposal. Key to the inventory measurement is a three detector HPGe high performance gamma spectroscopy system capable of recovering data at up to 90% saturation (200,000 counts per second). Data recovery is based on a unique embedded electronic pulser and specialized software to report the inventory. Each of the detectors have different shielding specified through Monte Carlo simulation with the MCNP program. This shielding provides performance over a dynamic range of eight orders of magnitude. System description, calibration issues and operational experiences are discussed.

  4. High performance gamma measurements of equipment retrieved from Hanford high-level nuclear waste tanks

    International Nuclear Information System (INIS)

    Troyer, G.L.

    1997-01-01

    The cleanup of high level defense nuclear waste at the Hanford site presents several progressive challenges. Among these is the removal and disposal of various components from buried active waste tanks to allow new equipment insertion or hazards mitigation. A unique automated retrieval system at the tank provides for retrieval, high pressure washing, inventory measurement, and containment for disposal. Key to the inventory measurement is a three detector HPGe high performance gamma spectroscopy system capable of recovering data at up to 90% saturation (200,000 counts per second). Data recovery is based on a unique embedded electronic pulser and specialized software to report the inventory. Each of the detectors have different shielding specified through Monte Carlo simulation with the MCNP program. This shielding provides performance over a dynamic range of eight orders of magnitude. System description, calibration issues and operational experiences are discussed

  5. Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd

    Directory of Open Access Journals (Sweden)

    D.Goodarzi Pour

    2005-02-01

    Full Text Available Statement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.Propose: The aim of this descriptive study is to evaluate the protection principles in centers which haveintraoral radiographic devices in Yazd.Material and Methods: We have considered all three aspects of practitioner, environment and patientprotection using questionnaire and visiting those centers.Results: 33/7% of dental offices ,10 clinics ,3 institution and faculty of dentistry had intraoral radiographicequipments. Stablishment of protection principles for radiographer was favorable. 7.7% of centers had x-ray room with leaded walls, 23.1% had curtain , in 69/2% of centers radiographers stood in correct position anddistance while taking radiograph. Regarding to protection of environment, beams leakage control in 23.1% dental offices, 70% of clinics, all institution and faculty of dentistry have done.Conclusion: Non of the centers used rectangular localizator, thyroid shield, film holder and just some centers used leaded apron in specific circumstances. We have concluded that patient protection constitute less consideration. Generally lack of protective consideration is related to deficient knowledge of operators. Lackof information about protection equipments causes decrease of demanding of these tools and ultimately lack of these equipments in the market.

  6. The role of a certified calibration laboratory in a station's measuring and test equipment calibration, repair, and documentation program

    International Nuclear Information System (INIS)

    Ebenstreit, K.; MacIntosh, N.

    1995-01-01

    This paper outlines the role of a Certified Calibration Laboratory in- ensuring that the requirements of Measuring and Test Equipment calibration, identification, and traceability are met and documented. The Nuclear environment is one which is subject to influences from numerous 'quality agents'. One of the fields which comes under the scrutiny of the quality agents is that of equipment calibration and repair (both field components and M and TE). There is a responsibility to produce a superior product for the Ontario Consumer. The maintenance and calibration of Station Systems and their components have a direct impact on this output. The Measuring and Test Equipment element in each of these needs can be addressed by having a defined group of Maintenance Staff to execute a Measuring and Test Equipment Program which meets specific parameters. (author)

  7. Measuring spin of black holes in the universe

    Indian Academy of Sciences (India)

    Table of contents. Measuring spin of black holes in the universe · What is black hole? Accretion Disk and Jet · What is black hole's spin? Accretion Disk · Black Hole's Potential · Light Curves: Photon Count Rate Vs Time · Quasi-Periodic Oscillation · Slide 9 · Model · Slide 11 · Slide 12 · Slide 13 · Summary.

  8. Towards improving security measures in Nigeria University Libraries ...

    African Journals Online (AJOL)

    A questionnaire designed by the researchers titled “Towards Improving Security Measures in Nigerian University Libraries (TISMINUL)” was used to collect the needed data. The questionnaire was designed in two parts. Part one was to gather information on the size of collection, frequency of stock taking and book loss.

  9. A universal measuring and monitoring system for nuclear radiation

    International Nuclear Information System (INIS)

    Genrich, V.

    1988-01-01

    Genitron Instruments, Frankfurt/Main, committed themselves to revise the 'conventional' concept of counting tube metrology. The goal was to develop a modular system that would allow large-area measuring tasks. The contribution in hand explains this development, which consists of a highly integrated measuring head that can be combined with various detector types, and complemented by various system components, to form a universal measuring and monitoring system for nuclear radiation. This modular design concept is capable of fulfilling a multitude of tasks, ranging from single, specific applications to non-stop monitoring tasks within a large-area measuring network. (orig./DG) [de

  10. Measurement of intraocular pressure using the NT-4000: a new non-contact tonometer equipped with pulse synchronous measurement function.

    Science.gov (United States)

    Yaoeda, Kiyoshi; Shirakashi, Motohiro; Fukushima, Atsushi; Funaki, Shigeo; Funaki, Haruko; Ofuchi, Nobutaka; Nakatsue, Tomoko; Abe, Haruki

    2005-06-01

    NT-4000 (Nidek Co. Ltd., Gamagori, Japan) is a new non-contact tonometer (NCT) equipped with pulse synchronous measurement function that can measure intraocular pressure (IOP) synchronized with the ocular pulse. The purpose of this study was to evaluate the usefulness of NT-4000 in normal subjects and in patients with glaucoma and ocular hypertension. This study included 175 eyes of 175 subjects. Firstly, the IOP was measured using NT-4000 without the pulse synchronous measurement function (NTn). Secondly, the IOP at peak, middle, and trough phases of the pulse signal were measured using NT-4000 with the pulse synchronous measurement function (NTp, NTm, NTt, respectively). Additionally, the IOP was measured with Goldmann applanation tonometer (GT). The coefficient of variation (CV) of three readings in the NCT measurements was used to evaluate the intra-session reproducibility. Statistical comparisons were performed using Wilcoxon signed rank test and one-way analysis of variance with Scheffe's test. Linear regression analysis was used to calculate correlation coefficients. P values less than 0.05 were accepted as statistically significant. The CV of NTn, NTp, NTm, and NTt were 6.4%, 5.5%, 4.9%, and 5.2%, respectively. The CV of NTp, NTm, and NTt were significantly smaller than that of NTn (P = 0.007, P < 0.001, P < 0.001, respectively). NTp was significantly higher than NTt (P = 0.038). GT was significantly correlated with NTn, NTp, NTm, and NTt (r = 0.898, P < 0.001; r = 0.912, P < 0.001; r = 0.908, P < 0.001; r = 0.900, P < 0.001, respectively). NT-4000 can detect the fluctuation of IOP associated with the ocular pulse.

  11. Description of the universal low-temperature measuring system

    International Nuclear Information System (INIS)

    Langfeld, R.; Maurer, C.

    1987-01-01

    There are various measuring methods for a characterization of semiconductor devices, especially for analysis of radiation effects after ion implantation. The four most important methods are: 1. Recording of voltage-current characteristics at pn-junctions or Schottky diodes. 2. Determination of the temperature dependence of the electrical resistance, e.g. of amorphous semiconductor layers, by feeding a constant voltage and measuring the current as a function of sample temperature. 3. Measurement of the resistive layer capacitance of a semiconductor diode as a function of the fed blocking voltage and determination of the doping concentration profile. 4. Time-resolved capacitance measurement after abrupt blocking-voltage alterations at pn - or Schottky diodes as a function of specimen temperature for determining defects in semiconductors, DLTS method. A measuring equipment has been set up that allows measurements being made in the temperature range between 14 K and 400 K, on up to eight specimens in one temperature test. Operating mode and handling of the computerized measuring program are described. (orig./HP) [de

  12. Measurements of mixtures with carbon dioxide under supercritical conditions using commercial high pressure equipment

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Luciana L.P.R. de; Rutledge, Luis Augusto Medeiros; Moreno, Eesteban L.; Hovell, Ian; Rajagopal, Krishnaswamy [Universidade Federal do Rio de Janeiro (LATCA-EQ-UFRJ), RJ (Brazil). Escola de Quimica. Lab. de Termodinamica e Cinetica Aplicada

    2012-07-01

    There is a growing interest in studying physical properties of binary and multicomponent fluid mixtures with supercritical carbon dioxide (CO{sub 2}) over an extended range of temperature and pressure. The estimation of properties such as density, viscosity, saturation pressure, compressibility, solubility and surface tension of mixtures is important in design, operation and control as well as optimization of chemical processes especially in extractions, separations, catalytic and enzymatic reactions. The phase behaviour of binary and multicomponent mixtures with supercritical CO{sub 2} is also important in the production and refining of petroleum where mixtures of paraffin, naphthene and aromatics with supercritical fluids are often encountered. Petroleum fluids can present a complex phase behaviour in the presence of CO{sub 2}, where two-phase (VLE and LLE) and three phase regions (VLLE) might occur within ranges of supercritical conditions of temperature and pressure. The objective of this study is to develop an experimental methodology for measuring the phase behaviour of mixtures containing CO{sub 2} in supercritical regions, using commercial high-pressure equipment. (author)

  13. Universal uncertainty principle in the measurement operator formalism

    International Nuclear Information System (INIS)

    Ozawa, Masanao

    2005-01-01

    Heisenberg's uncertainty principle has been understood to set a limitation on measurements; however, the long-standing mathematical formulation established by Heisenberg, Kennard, and Robertson does not allow such an interpretation. Recently, a new relation was found to give a universally valid relation between noise and disturbance in general quantum measurements, and it has become clear that the new relation plays a role of the first principle to derive various quantum limits on measurement and information processing in a unified treatment. This paper examines the above development on the noise-disturbance uncertainty principle in the model-independent approach based on the measurement operator formalism, which is widely accepted to describe a class of generalized measurements in the field of quantum information. We obtain explicit formulae for the noise and disturbance of measurements given by measurement operators, and show that projective measurements do not satisfy the Heisenberg-type noise-disturbance relation that is typical in the gamma-ray microscope thought experiments. We also show that the disturbance on a Pauli operator of a projective measurement of another Pauli operator constantly equals √2, and examine how this measurement violates the Heisenberg-type relation but satisfies the new noise-disturbance relation

  14. Development of Universal Methodology of Specimen Free Nondestructive Inspection (Control) of Mechanical Properties of NPP Equipment Metal in all Stages of Lifetime

    International Nuclear Information System (INIS)

    Bakirov, M.; Chubarov, S.; Frolov, I.; Kiselev, I.; Gastrock, J.; Dripke, M.

    2011-01-01

    Ever-increasing requirements for reliability and safety of equipment in nuclear power plants (NPP) dictate a necessity to obtain reliable and validated information about the condition of materials in the most safety-relevant and economically vital systems structures and components (SSC). Thus it is a state of science and technology approach to use one method, one methodic and one methodology to facilitate these goals with the purpose of keeping NPPs operating safely by virtue of knowing the state of ageing they are in (with respect to design limits and margins). Method of the control/measurement/testing - how to conduct measurements; methodic - how to interpret the results of measurement; methodology - the program of the control/inspection and testing programmes: localities to conduct the tests, how often, and to follow evolution of test results with the aim of acting before a failure occurs. Such methodology should be based on the use of specimen-free nondestructive method of the inspection (control), which could be used, successfully at all stages of life cycle of the equipment: manufacturing, construction, installation of NPP, operation and during the NPP operation through integration into the Plant Life Management (PLiM) Programme. It will facilitate a real picture of change (degradation) of a SSC material's condition in the zones subjected to the harshest stressors (neutron irradiation, erosion-corrosion/flow, thermal fatigue, vibration etc). Currently, there are various approaches used in the world to follow NPP ageing degradation, but until now, no specific methodology is used that could supply all the necessary information. Therefore, there is no way to use various results. Thanks to considerable advances over the last 20 years or so, the science of hardness testing offers an elegant, non-destructive way to obtain vital materials properties - even in-situ on operating SSC. In particular, the material's elastic-plastic condition may be measured, giving

  15. Technological problems and counter-measures on equipment materials for reprocessing of high burnup fuels

    International Nuclear Information System (INIS)

    Kiuchi, K.; Kato, T.; Motooka, H.; Hamada, S.

    2002-01-01

    The reliability of structural materials is considered as one of the most important technological issues on the commercial reprocessing of high burnup fuels. The durability prediction study of equipment materials used in commercial purex process has been conducted in the JAERI. From the experimental results obtained by scaled mock-up tests and laboratory tests, the stress corrosion cracking (SCC) for a dissolvor made of zirconium and the trans-passive corrosion of heat transfer tubes for evaporators made of austenitic stainless steels have been clarified as critical issues on the reliability. The susceptibility to these failures increases with the amount of TRU and FP elements included in spent fuels, because Np, Pu, Ru, Pd act as strong oxidizers. As counter-measures against these problems, the development of the modified alloys is going on in the JAERI. It has been found that the intergranular corrosion resistance of stainless steels is possible to be completely improved by purifying the electron beam melting process and by modifying the metallographic structure. The other counter measure is to inhibit the trans-passive corrosion by addition of oxide film former elements such as W and Si. It has also been found that the susceptibility to SCC of Zr can be improved by addition of titanium. However, the addition of titanium decreases the corrosion resistance of Zr. We selected niobium alloys as alternative materials to zirconium. By addition of tungsten to the niobium, the corrosion resistance and the mechanical strength have been improved. This niobium alloy can be used in heavily corrosive nitric acid contaminated with fluorine. It is considered that the difference between corrosion resistance of Zr and Nb-alloys is attributed to the chemical stability of the oxide films (MO 2 on Zr and M 2 O 5 on Nb). (author)

  16. Jagiellonian University Polarized Drell-Yan measurements at COMPASS

    CERN Document Server

    Longo, R

    2017-01-01

    COMPASS is a fixed-target experiment operating on north area of SPS (M2 beamline) at CERN. An important part of the physics programme of the experiment is the exploration of the transverse spin structure of the nucleon via measurements of spin-(in)dependent azimuthal asymmetries in the semi-inclusive DIS and, recently, also in Drell-Yan processes. Drell-Yan measurements with a 190 GeV/c $\\pi^-$ beam impinging on a transversely polarized NH3 target started in the year 2015 (18 weeks data taking) and will be continued in 2018. The measurement of the Sivers and other azimuthal asymmetries in polarized SIDIS and Drell-Yan performed by COMPASS provides a unique possibility to test (pseudo-)universal features of transverse momentum-dependent parton distribution functions, predicted in QCD. In this review, results of the first ever measurements of the polarized Drell-Yan reaction performed by COMPASS are presented.

  17. Development and calibration automatic equipment's measuring in real time of the environmental radioactivity by gamma spectrometry

    International Nuclear Information System (INIS)

    Casanovas, R.; Morant, J. J.; Salvado, M.

    2013-01-01

    In this paper, we describe the general aspects of the implementation of gamma spectrometry in water, as well as the development of two measuring devices based on this technique: aerosol monitor (RARM-F) and a monitor direct measurement (RARMD2) , both patent applications. Furthermore, they described in detail the aspects of calibration of equipment, which has been made by combining experimental measurements with Monte Carlo simulations. (Author)

  18. To Strengthen the Instrument and Equipment Management of Laboratories in Colleges and Universities%加强实验室仪器设备的科学管理

    Institute of Scientific and Technical Information of China (English)

    李培天

    2001-01-01

    高等学校实验室仪器设备管理水平的高低对教学质量和办学效益的好坏有直接影响。管理得好,就会充分发挥其作用,提高教学质量和办学效益;否则,就会闲置浪费,甚至造成损失。%The instrument and equipment management of laboratories in colleges and universities directly affectsthe quality of teaching and the benefit of running a school. With good management, the instrument and equipment will be brought into full play, therefore improve the quality of teaching and the benefit of running aschool; otherwise, the instrument and equipment will be lain idle and wasted even lost to some extent.

  19. Astronomers Take the Measure of Dark Matter in the universe

    Science.gov (United States)

    2001-09-01

    Using NASA's Chandra X-ray Observatory, astronomers have obtained their most accurate determination to date of the amount of dark matter in galaxy clusters, the most massive objects in the universe. The results provide an important step towards a precise measurement of the total matter density of the universe. These results were presented today by Steven W. Allen of the Institute of Astronomy in Cambridge, UK at a press conference at the `Two Years of Science with Chandra' symposium in Washington, DC. Allen and his colleagues Robert W. Schmidt and Andrew C. Fabian at the Institute of Astronomy observed a carefully chosen sample of five of the largest clusters of galaxies known, whose distances range from 1.5 to 4 billion light years. The team made temperature maps of the hot multimillion-degree gas that fills the clusters. "The temperature maps can be used to determine the mass needed to prevent the hot gas from escaping the clusters" explained Allen. "We found that the stars in the galaxies and hot gas together contribute only about 13 percent of the mass. The rest must be in the form of dark matter." The nature of the dark matter is not known, but most astronomers think that it is in the form of an as yet unknown type of elementary particle that contributes to gravity through its mass but otherwise interacts weakly with normal matter. These dark matter particles are often called WIMPs, an acronym for `weakly interacting massive particles'. Clusters of galaxies are vast concentrations of galaxies, hot gas and dark matter spanning millions of light years, held together by gravity. Because of their size, clusters of galaxies are thought to provide a fair sample of the proportion of dark matter in the universe as a whole. "The implication of our results is that we live in a low-density universe" said Allen. "The total mass-density is only about thirty percent of that needed to stop the universe from expanding forever." The result reinforces recent findings from

  20. Particle emissions from ventilation equipment: health hazards, measurement and product development; Ilmanvaihtolaitteiden hiukkaspaeaestoet: terveyshaitat, mittaaminen ja tuotekehitys

    Energy Technology Data Exchange (ETDEWEB)

    Tossavainen, A.; Tuovila, H.; Riala, R.; Harju, R.; Tuomi, T.; Voutilainen, R. [Tyoeterv.l, Helsinki (Finland); Laamanen, J.; Ismo Heimonen, I.; Kovanen, K. [VTT, Espoo (Finland)

    2006-10-15

    The project aimed to develop the design, structure and materials of ventilation equipment for the improvement of indoor air quality in office- type buildings. Particle emissions from commercial sound silencers were measured by laboratory tests. In ten buildings, the dust and fibre levels were surveyed in relation to the product design and operation. Direct-reading particle counters and filter sampling methods combined with optical and electron microscopy analyses were the main methods in these surveys. Nasal lavage was used for the estimation of inhalation exposure to coarse man-made mineral fibres. Technical criteria were drafted for the design and testing of fibre emissions from various ventilation equipment. (orig.)

  1. Upgrade of a radiation measurement laboratory course at the University of Florida

    International Nuclear Information System (INIS)

    Thomsen, L.M.; Bolch, W.E.; Wagner, T.H.

    1996-01-01

    The open-quotes Nuclear Radiation Detection and Instrumentation Laboratoryclose quotes course at the University of Florida provides health physics students with virtually their only hands-on exposure to the radiation measurement equipment used in professional practice. To better prepare students for employment, the course is currently under revision, with implementation of the revised course scheduled for fall semester 1996. The primary goal is to improve student understanding of the inherent strengths and limitations of various gas-filled, scintillation, and semiconductor detectors. A secondary goal is to improve student writing skills. To devise lab exercises that meet these goals, a six-step method for systematic laboratory course improvement was developed and used to guide the revision process. First, course objectives were delineated. Second, obstacles to achieving these course objectives were candidly assessed. Third, the course objectives were prioritized to ensure that the most important ones were met within the given time and equipment constraints. Fourth, performance-based learning objectives were written for each exercise. Fifth, exercises were developed that enable students to achieve the learning objectives specified. Sixth, when the revised course is implemented, its teaching effectiveness will be measured and steps will be taken to improve further. Course revision is nearly complete, and the new exercises promise to significantly improve both student technical knowledge and communication skill

  2. Particle emissions from ventilation equipment: health hazards, measurement and product development; Ilmanvaihtolaitteiden hiukkaspaeaestoet: terveyshaitat, mittaaminen ja tuotekehitys - ILMI

    Energy Technology Data Exchange (ETDEWEB)

    Tossavainen, A.; Paananen, H.; Riala, R.; Tuomi, T.; Voutilainen, R. [Finnish Institute of Occupational Health, Helsinki (Finland); Heimonen, I.; Kovanen, K. [VTT Building and Transport, Espoo (Finland)

    2004-07-01

    The project will develop the design, structure and materials of ventilation equipment for the improvement of indoor air quality in office-type buildings. Particle emissions from commercial products are measured by laboratory tests. In ten buildings, the dust and fibre levels will be surveyed in relation to the design and operation of the ventilation equipment. Direct-reading particle counters and filter sampling method combined with optical and electron microscopy analyses are the main methods in these surveys. Nasal lavage is used for the estimation of inhalation exposure to coarse man-made mineral fibres. Technical criteria will be drafted for the design and testing of fibre emissions from various ventilation equipment. (orig.)

  3. Procedure for field axes measurement, beam indication adjustment, and figure of convergence determination within performance tests for radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    Quast, U; Krause, K; Rassow, J [Essen Univ. (Gesamthochschule) (Germany, F.R.). Abt. fuer Klinische Strahlenphysik

    1976-09-01

    A routine measuring procedure for the verification of radiation field axes and figure of convergence within a spatial resolution of +- 0.5 mm is described. Measurements are done in two parallel planes in a certain distance before and behind the presumed isocentre. The used test arrangement permits rapid check and controlled adjustment of the alignment of beam or isocentre indicating devices for all isocentric radiation therapy equipment.

  4. Neutrinos help reconcile Planck measurements with the local universe.

    Science.gov (United States)

    Wyman, Mark; Rudd, Douglas H; Vanderveld, R Ali; Hu, Wayne

    2014-02-07

    Current measurements of the low and high redshift Universe are in tension if we restrict ourselves to the standard six-parameter model of flat ΛCDM. This tension has two parts. First, the Planck satellite data suggest a higher normalization of matter perturbations than local measurements of galaxy clusters. Second, the expansion rate of the Universe today, H0, derived from local distance-redshift measurements is significantly higher than that inferred using the acoustic scale in galaxy surveys and the Planck data as a standard ruler. The addition of a sterile neutrino species changes the acoustic scale and brings the two into agreement; meanwhile, adding mass to the active neutrinos or to a sterile neutrino can suppress the growth of structure, bringing the cluster data into better concordance as well. For our fiducial data set combination, with statistical errors for clusters, a model with a massive sterile neutrino shows 3.5σ evidence for a nonzero mass and an even stronger rejection of the minimal model. A model with massive active neutrinos and a massless sterile neutrino is similarly preferred. An eV-scale sterile neutrino mass--of interest for short baseline and reactor anomalies--is well within the allowed range. We caution that (i) unknown astrophysical systematic errors in any of the data sets could weaken this conclusion, but they would need to be several times the known errors to eliminate the tensions entirely; (ii) the results we find are at some variance with analyses that do not include cluster measurements; and (iii) some tension remains among the data sets even when new neutrino physics is included.

  5. Reduced medical and occupational exposures by optimizing working procedures in fluoroscopy equipment in the University Hospital of Santa Maria (RS)

    International Nuclear Information System (INIS)

    Weis, Guilherme L.; Claus, Thiago V.; Baumhardt, Tadeu; Shuch, Luiz A.

    2013-01-01

    This work seeks to reduce medical (patient) and occupational (workers) exposure by standardizing resources available in fluoroscopy equipment used in interventional procedures. Such procedures use transportable surgical arch type fluoroscopy equipment, with applications in orthopedics, angiography and pacemaker implantation. Improper use of these devices generates excessive radiation doses in both patients and the medical staff. It is observed that the equipment after being connected to the grid, is pre-selected to work in continuous fluoroscopy and no additional filtration, producing higher doses of radiation. For specific applications, changes in protocols should be undertaken according to medical indication. This work used a fluoroscopy equipment Shimadzu Active Opescope two radiation monitoring equipment, brand Radcal, models 9010 and 9015, two ionization chambers, of 60 cc and 180 cc and a low contrast phantom and a catheter, information that simulate the human body. Incidences were performed by changing the conditions of exposure as frame rates (fps - frames per second) and additional filtration. For each composition parameters was generated and filed an image, with the extent of their respective doses. These images were evaluated by radiologists. In more extreme cases we obtained a reduction of a factor 25 in occupational exposure (medical personnel) using the pulsed with the greatest 2 fps additional filter (0.3 mm Cu) compared to continuous system without any additional filtration. In medical exposure (of patients), decreased by a factor 39, the same conditions described above. With these arguments it is justified the optimization and standardization of the equipment used in fluoroscopy, which besides providing a dose reduction the patient and the medical personnel, increases the life of the X-ray tube while maintaining the quality of medical diagnosis. (author)

  6. The application of nuclear equipment to measurement and control in the steel industry

    International Nuclear Information System (INIS)

    Van Schalkwyk, J.

    1976-01-01

    In this paper, some of the reasons for utilising equipment which makes use of nuclear radiation for the control of processes in the steel industry will be discussed. Two applications will be analysed to demonstrate the reasoning and to highlight some of the factors and principles [af

  7. Measurements on a PV solar pump equipped with a piston pump with a matching valve

    NARCIS (Netherlands)

    Smulders, P.T.; Ten Thije O.G. Boonkkamp, J.; Borg, van der N.J.C.M.; Beek, van M.

    1997-01-01

    The work on a simple high efficient solar pump equipped with a piston pump with a matching valve, reported at the Solar World Congress in Budapest, has been continued. Quasi-static and dynamic models of the solar pump have been derived with which the operation of the system is simulated. A test rig

  8. Manufacture research of the test equipment to measure the dose rate in high radiation medium

    International Nuclear Information System (INIS)

    Phan Luong Tuan; Nguyen Van Sy; Nguyen Xuan Vinh; Dang Quang Bao; Nguyen Thanh Hung; Pham Minh Duc; Nguyen Xuan Truong

    2017-01-01

    Photodiode BPW34 is operated as a low voltage counter tubes. When the radiation rays go into the BPW34,they will create a pairs of electron and hole. If setting the reverse bias in to the BPW34, a pulse is achieved and it can be amplified and processed. The STM32 is the microcontroller family which is developed base on ARM processors. The STM32 incorporated many new features such as ADC, I2C, etc. With the connectional ability to other devices, the STM32 is proving its advantages in the development of equipment.The application of irradiation technology in the economy-society increases widespread as food irradiation, mutant irradiation, etc. Until now the calculation the high dose rate at Hanoi Irradiation Center is identified by the Fricke, ECB dosimeters. The dosimeters must be destroyed in order to serve for dose rate determination. Manufacture research the equipment for dose rate calculation support to determine dose rate directly through the equipment’s signal and this equipment can be used multiple. This equipment can be connected to other devices to control the irradiation process better via signals. (author)

  9. RISK ASSESSMENT BY STRUCTURAL ANALYSIS AND VIBRATION MEASUREMENT EQUIPMENT OPERATING AT OIL FACILITIES

    Directory of Open Access Journals (Sweden)

    Marius STAN

    2013-05-01

    Full Text Available Vibration analysis applications in operation is one of the diagnostic methods ofoperation of the facility. Analysis of these types of failures indicated the existence of specificfeatures prints and related equipment vibration spectra. Modeling and identification of theseparticular aspects in the spectrum of vibration machines help to control the operation of oilfacilities built safely.

  10. RISK ASSESSMENT BY STRUCTURAL ANALYSIS AND VIBRATION MEASUREMENT EQUIPMENT OPERATING AT OIL FACILITIES

    OpenAIRE

    Marius STAN

    2013-01-01

    Vibration analysis applications in operation is one of the diagnostic methods ofoperation of the facility. Analysis of these types of failures indicated the existence of specificfeatures prints and related equipment vibration spectra. Modeling and identification of theseparticular aspects in the spectrum of vibration machines help to control the operation of oilfacilities built safely.

  11. Using PHM to measure equipment usable life on the Air Force's next generation reusable space booster

    Science.gov (United States)

    Blasdel, A.

    The U.S. Air Force procures many launch vehicles and launch vehicle services to place their satellites at their desired location in space. The equipment on-board these satellite and launch vehicle often suffer from premature failures that result in the total loss of the satellite or a shortened mission life sometimes requiring the purchase of a replacement satellite and launch vehicle. The Air Force uses its EELV to launch its high priority satellites. Due to a rise in the cost of purchasing a launch using the Air Force's EELV from 72M in 1997 to as high as 475M per launch today, the Air Force is working to replace the EELV with a reusable space booster (RSB). The RSB will be similar in design and operations to the recently cancelled NASA reusable space booster known as the Space Shuttle. If the Air Force uses the same process that procures the EELV and other launch vehicles and satellites, the RSB will also suffer from premature equipment failures thus putting the payloads at a similar high risk of mission failure. The RSB is expected to lower each launch cost by 50% compared to the EELV. The development of the RSB offers the Air Force an opportunity to use a new reliability paradigm that includes a prognostic and health management program and a condition-based maintenance program. These both require using intelligent, decision making self-prognostic equipment The prognostic and health management program and its condition-based maintenance program allows increases in RSB equipment usable life, lower logistics and maintenance costs, while increasing safety and mission assurance. The PHM removes many decisions from personnel that, in the past resulted in catastrophic failures and loss of life. Adding intelligent, decision-making self-prognostic equipment to the RSB will further decrease launch costs while decreasing risk and increasing safety and mission assurance.

  12. A hybrid degradation tendency measurement method for mechanical equipment based on moving window and Grey–Markov model

    International Nuclear Information System (INIS)

    Jiang, Wei; Zhou, Jianzhong; Zheng, Yang; Liu, Han

    2017-01-01

    Accurate degradation tendency measurement is vital for the secure operation of mechanical equipment. However, the existing techniques and methodologies for degradation measurement still face challenges, such as lack of appropriate degradation indicator, insufficient accuracy, and poor capability to track the data fluctuation. To solve these problems, a hybrid degradation tendency measurement method for mechanical equipment based on a moving window and Grey–Markov model is proposed in this paper. In the proposed method, a 1D normalized degradation index based on multi-feature fusion is designed to assess the extent of degradation. Subsequently, the moving window algorithm is integrated with the Grey–Markov model for the dynamic update of the model. Two key parameters, namely the step size and the number of states, contribute to the adaptive modeling and multi-step prediction. Finally, three types of combination prediction models are established to measure the degradation trend of equipment. The effectiveness of the proposed method is validated with a case study on the health monitoring of turbine engines. Experimental results show that the proposed method has better performance, in terms of both measuring accuracy and data fluctuation tracing, in comparison with other conventional methods. (paper)

  13. A hybrid degradation tendency measurement method for mechanical equipment based on moving window and Grey-Markov model

    Science.gov (United States)

    Jiang, Wei; Zhou, Jianzhong; Zheng, Yang; Liu, Han

    2017-11-01

    Accurate degradation tendency measurement is vital for the secure operation of mechanical equipment. However, the existing techniques and methodologies for degradation measurement still face challenges, such as lack of appropriate degradation indicator, insufficient accuracy, and poor capability to track the data fluctuation. To solve these problems, a hybrid degradation tendency measurement method for mechanical equipment based on a moving window and Grey-Markov model is proposed in this paper. In the proposed method, a 1D normalized degradation index based on multi-feature fusion is designed to assess the extent of degradation. Subsequently, the moving window algorithm is integrated with the Grey-Markov model for the dynamic update of the model. Two key parameters, namely the step size and the number of states, contribute to the adaptive modeling and multi-step prediction. Finally, three types of combination prediction models are established to measure the degradation trend of equipment. The effectiveness of the proposed method is validated with a case study on the health monitoring of turbine engines. Experimental results show that the proposed method has better performance, in terms of both measuring accuracy and data fluctuation tracing, in comparison with other conventional methods.

  14. Process and equipment for automatic measurement of resonant frequencies in seismic detectors

    International Nuclear Information System (INIS)

    Fredriksson, O.A.; Thomas, E.L.

    1977-01-01

    This is a process for the automatic indication of the resonant frequency of one or more detector elements which have operated inside a geophysical data-gathering system. Geophones or hydrophones or groups of both instruments are to be understood as comprising the detector elements. The invention concerns the creation of a process and of equipment working with laboratory precision, although it can be used in the field. (orig./RW) [de

  15. A system of radiation monitoring, and methods and equipment for measuring water of low specific activity

    International Nuclear Information System (INIS)

    Sivintsev, Yu.V.

    1975-01-01

    The author considers criteria for the radiation protection of the population and the environment. He describes the role of procedures for monitoring waters of low specific activity in the framework of a system for ensuring the radiation safety of the population living near a nuclear power station. The main technical characteristics (background, efficiency, sensitivity) of the laboratory equipment for gamma spectrometric analysis of water samples of low specific activity are discussed. (author)

  16. New methodology to measure kVp in X-rays equipment for radiodiagnosis

    International Nuclear Information System (INIS)

    Vega Ramirez, J.L.; Pela, C.A.

    1998-01-01

    The work aims to obtain through experiments a spaced out sensibilization (different optical densities) in the X-rays film by letting X-rays photons go through a metallic layer of copper with tiers with different thickness that can cover the range of kVps employed in radiological tests. Results for the kVp shown here were also compared with other equipment available in the market. Comparisons showed their similarity but have also the advantage of being cheap and viable

  17. A study on measuring the quality of university website

    Directory of Open Access Journals (Sweden)

    Zahra Andalib

    2013-07-01

    Full Text Available During the past few years, many organizations try to provide some of their services through their websites. This would help them provide fast and reliable services to various people around the world. In this paper, we present an empirical survey to measure the relative performance of a university website in Iran using Parasuraman's technological readiness index. The proposed study uses a standard questionnaire and distributes it among 387 active website users and the results are analyzed using structural equation modeling. The proposed study of this paper considers the effects of four factors including efficiency, accessibility, achievement and security on customer loyalty via two variables of trust and satisfaction. The results demonstrate that three components of trust, efficiency and achievement play essential role on customer loyalty.

  18. Jagiellonian University Selected measurements of rare decays at the LHCb

    CERN Document Server

    INSPIRE-00392248

    2017-01-01

    The LHCb spectrometer is specifically designed to study heavy-flavour physics. These proceedings present a selection of rare decays analyses performed with 1 fb−1 and 2 fb−1 of proton–proton collision data collected at the center-of-mass energies of 7 and 8 TeV, respectively. Rare decays are highly suppressed (or forbidden) in the Standard Model, thus could provide indirect evidence of New Physics. Results of the angular analyses of the B0 → K∗0μ+μ−, B0 → K∗0e+e−, Λb0 → Λμ+μ−, and Bs0 → ϕμ+μ− decays, along with branching fraction measurements for the latter two channels, are summarized. In addition, a test of lepton flavour universality in B+ → K+ℓℓ decays and searches for the lepton flavour violating decays are presented.

  19. A reliable measure of footwear upper comfort enabled by an innovative sock equipped with textile pressure sensors.

    Science.gov (United States)

    Herbaut, Alexis; Simoneau-Buessinger, Emilie; Barbier, Franck; Cannard, Francis; Guéguen, Nils

    2016-10-01

    Footwear comfort is essential and pressure distribution on the foot was shown as a relevant objective measurement to assess it. However, asperities on the foot sides, especially the metatarsals and the instep, make its evaluation difficult with available equipment. Thus, a sock equipped with textile pressure sensors was designed. Results from the mechanical tests showed a high linearity of the sensor response under incremental loadings and allowed to determine the regression equation to convert voltage values into pressure measurements. The sensor response was also highly repeatable and the creep under constant loading was low. Pressure measurements on human feet associated with a perception questionnaire exhibited that significant relationships existed between pressure and comfort perceived on the first, the third and the fifth metatarsals and top of the instep. Practitioner Summary: A sock equipped with textile sensors was validated for measuring the pressure on the foot top, medial and lateral sides to evaluate footwear comfort. This device may be relevant to help individuals with low sensitivity, such as children, elderly or neuropathic, to choose the shoes that fit the best.

  20. Shaping the Future: Integrating Cutting Edge Equipment to Enhance Research, Education and Outreach at Nova Southeastern University

    Science.gov (United States)

    2015-04-30

    antibiotic resistance and preventing the spread of infectious disease . These projects include 1) uncovering how the inoculum effect can drive spontaneous...bacterial infections. Furthermore, our results may have implications in controlling the spread of infectious diseases and the spread of invasive...equipment. For instance, a new faculty member starting this fall will be bringing dental pulp stem cells, collaborations will continue with pharmacology

  1. Update of computer applications associated to measuring equipment of the services of internal dosimetry of NPPS and Tecnatom

    International Nuclear Information System (INIS)

    Bravo, B.; Sollet, E.; Serrano, E.

    2014-01-01

    Within the continuous improvement processes that take place in all the activities taking place in the Spanish nuclear power plants, and as a result of implementation of ISO Standards for Internal Dosimetry, has undertaken a review, improvement and updating INDAC ALEDIN and applications associated with measuring equipment and DIYs Quicky kind Personal Internal Dosimetry Services of the Spanish nuclear power plants and Tecnatom This paper presents updates capacities both tools. (Author)

  2. University Rankings: How Well Do They Measure Library Service Quality?

    Science.gov (United States)

    Jackson, Brian

    2015-01-01

    University rankings play an increasingly large role in shaping the goals of academic institutions and departments, while removing universities themselves from the evaluation process. This study compares the library-related results of two university ranking publications with scores on the LibQUAL+™ survey to identify if library service quality--as…

  3. Variability at Multiple Scales: Using an Array of Current- and Pressure-Sensor Equipped Inverted Echo Sounders to Measure the Ocean

    Science.gov (United States)

    2016-11-29

    of Current- and Pressure - Sensor Equipped Inverted Echo Sounders to Measure the Ocean 5b. GRANT NUMBER NOOO 14-15-1-2857 5c. PROGRAM ELEMENT NUMBER...inverted echo sounders (lESs) equipped with pressure and current sensors (CPIESs). CPIESs are moored instruments that measure the round-trip acoustic...at a range of spatial and temporal scales. The goals of this project were to enhance the pool of pressure - sensor equipped lESs available at the

  4. External meeting - Geneva University: Precision measurements in spin physics

    CERN Multimedia

    2007-01-01

    GENEVA UNIVERSITY ECOLE DE PHYSIQUE Département de physique nucléaire et corspusculaire 24, Quai Ernest-Ansermet 1211 GENEVE 4 - Tél: 022 379 62 73 - Fax: 022 379 69 92 Wednesday 28 March 2007 PARTICLE PHYSICS SEMINAR at 17:00 - Stückelberg Auditorium Precision measurements in spin physics by Dr. Steven Bass / CERN - Innsbruck The proton spin problem has been challenging experimentalists and theorists alike for the last 20 years. Polarized deep inelastic scattering experiments at CERN, DESY and SLAC have told us that quark partons contribute only about 30% of the proton's spin whereas relativistic quark models predict 60%. Where is the missing spin and why is the quark spin contribution so small? In this talk I will give an overview of the proton spin problem and what it may be telling us about QCD, the vacuum and dynamical symmetry breaking. A precise measurement of neutrino-proton elastic scattering would make a vital contribution to resolving many of the outstanding issues. Information: http://dpnc...

  5. Dose measurements in laboratory of Physics department, University of Khartoum

    International Nuclear Information System (INIS)

    Hamid, Maria Mohammed

    1999-05-01

    Personal monitoring in University of Khartoum is being conducted using thermoluminescent dosimetry. The purpose of the study is to measure the dose of radiation in laboratory of Physics in physics department. TL phosphors LiF: Mg, Ti (card) and LiF Mg, Cu, P (GR-200) and mini-rad dosimeter are used to measure the dose in laboratory. The total dose for students form the laboratory bu using card, GR-200 and mini-rad dosimeter was found to be 2.2μ sv/year. 2.5 μ sv/year and 2.6 μ sv respectively, and for the teacher about 4.0 μ sv/year, 5.8 μ sv/year and 13.6 μ sv/year respectively, and for the dose near junk room about 3.9 μ sv/year, 2.9 μ sv/year and 2.8 μ sv/year by using card, GR-200 and mini-rad dosimeter respectively. There is just a background radiation in the main library and the applied nuclear.(Author)

  6. A Fine-Tooth Comb to Measure the Accelerating Universe

    Science.gov (United States)

    2008-09-01

    Astronomical instruments needed to answer crucial questions, such as the search for Earth-like planets or the way the Universe expands, have come a step closer with the first demonstration at the telescope of a new calibration system for precise spectrographs. The method uses a Nobel Prize-winning technology called a 'laser frequency comb', and is published in this week's issue of Science. Uncovering the disc ESO PR Photo 26a/08 A Laser Comb for Astronomy "It looks as if we are on the way to fulfil one of astronomers' dreams," says team member Theodor Hänsch, director at the Max Planck Institute for Quantum Optics (MPQ) in Germany. Hänsch, together with John Hall, was awarded the 2005 Nobel Prize in Physics for work including the frequency comb technique. Astronomers use instruments called spectrographs to spread the light from celestial objects into its component colours, or frequencies, in the same way water droplets create a rainbow from sunlight. They can then measure the velocities of stars, galaxies and quasars, search for planets around other stars, or study the expansion of the Universe. A spectrograph must be accurately calibrated so that the frequencies of light can be correctly measured. This is similar to how we need accurate rulers to measure lengths correctly. In the present case, a laser provides a sort of ruler, for measuring colours rather than distances, with an extremely accurate and fine grid. New, extremely precise spectrographs will be needed in experiments planned for the future European Extremely Large Telescope (E-ELT), which is being designed by ESO, the European Southern Observatory. These new spectrographs will need to be calibrated with even more accurate 'rulers'. In fact, they must be accurate to about one part in 30 billions - a feat equivalent to measuring the circumference of the Earth to about a millimetre! "We'll need something beyond what current technology can offer, and that's where the laser frequency comb comes in. It is

  7. Technique and equipment for measuring volume activity of radon in the air of radon laboratories and clinics

    International Nuclear Information System (INIS)

    Vorob'ev, I.B.; Krivokhatskij, A.S.; Nekrasov, E.V.; Nikolaev, V.A.; Potapov, V.G.; Terent'ev, M.V.

    1990-01-01

    Usability of a new equipment-technique combination for measuring radon activity in the air of radon laboratories and balneological clinics is studied. The complex includes nitrate-cellulose detector, radon chamber, Aist, Istra type spark counters and technique of spark counting. The method sensitivity is 50 Bqxm 3 , the error is 30%. Usability and advisability of track method in radon laboratories and balneological clinics for simultaneous measurement in several points of integral volumetric radon activities are confirmred. The method permits to carry out rapid and accurate bulk investigations. The results of determining mean volumetric radon activity in the air in different points of radon laboratory and radon clinics are presented

  8. A description of the equipment for time-of-flight spectrum measurements on the fast reactor ZEBRA

    International Nuclear Information System (INIS)

    Gibson, I.H.; Jakeman, D.; Sanders, J.E.

    1969-05-01

    The pulsed source for the time-of-flight equipment consists of 14 MeV S-band linear electron accelerator, drift tube and water-cooled uranium-molybdenum alloy target installed on the ZEBRA lattice. Neutrons are extracted via a probe tube inserted into the core and an evacuated flight tube with counting stations at 50 m, 97 m and 200 m from the core centre. Two types of neutron detector are described and also the Perranti Argus 500 on-line computer which is used for data collection. The equipment is used for measuring the neutron energy spectra from the lowest energies up to about 1 MeV. (author)

  9. Global Coverage Measurement Planning Strategies for Mobile Robots Equipped with a Remote Gas Sensor

    Directory of Open Access Journals (Sweden)

    Muhammad Asif Arain

    2015-03-01

    Full Text Available The problem of gas detection is relevant to many real-world applications, such as leak detection in industrial settings and landfill monitoring. In this paper, we address the problem of gas detection in large areas with a mobile robotic platform equipped with a remote gas sensor. We propose an algorithm that leverages a novel method based on convex relaxation for quickly solving sensor placement problems, and for generating an efficient exploration plan for the robot. To demonstrate the applicability of our method to real-world environments, we performed a large number of experimental trials, both on randomly generated maps and on the map of a real environment. Our approach proves to be highly efficient in terms of computational requirements and to provide nearly-optimal solutions.

  10. Prospective technologies and equipment for sanitary hygienic measures for life support systems

    Science.gov (United States)

    Shumilina, I. V.

    Creation of optimal sanitary hygienic conditions is a prerequisite for good health and performance of crews on extended space missions. There is a rich assortment of associated means, methods and equipment developed and experimentally tested in orbital flights. However, over a one-year period a crew of three uses up about 800 kg of ground-supplied wet wipes and towels for personal needs. The degree of closure of life support systems for long-duration orbital flights should be maximized, particularly for interplanetary missions, which exclude any possibility of re-supply. Washing with regenerated water is the ultimate sanitary hygienic goal. That is why it is so important to design devices for crew bathing during long-term space missions. Investigations showed that regeneration of wash water (WW) using membrane processes (reverse osmosis, nanofiltration etc.), unlike sorption, would not require much additional expendables. A two-stage membrane recovery unit eliminated >85% of permeate from real WW with organic and inorganic selectivity of 82 95%. The two-stage WW recovery unit was tested with artificial and real WW containing detergents available for space crews. Investigations into the ways of doing laundry and drying along with which detergents will be the best fit for space flight are also planned. Testing of a technology for water extraction from used textiles using a conventional period of contact of 1 s or more, showed that the humidity of the outgoing air flow neared 100%. Issues related to designing the next generation of space life support systems should consider the benefits of integrating new sanitary hygienic technologies, equipment, and methods.

  11. Design of electronic measurement and quench detection equipment for the Current Lead Test facility Karlsruhe (CuLTKa)

    International Nuclear Information System (INIS)

    Hollik, Markus; Fietz, Walter H.; Fink, Stefan; Gehrlein, Mirko; Heller, Reinhard; Lange, Christian; Möhring, Tobias

    2013-01-01

    The Current Lead Test facility Karlsruhe (CuLTKa) is under construction at the Karlsruhe Institute of Technology (KIT) to perform acceptance tests of high temperature superconductor (HTS) current leads (CL). CuLTKa is in progress and present planning expects the completion in 2013. The data acquisition system is based on a modular design with electronic measurement and monitoring equipment covering a test voltage of 50 kV DC against ground. It provides plug-in units which enable temperature and voltage measurement at high voltage potential and in addition quench detection units which detect a loss of superconductivity reliably and quickly to avoid damage of the superconducting device under test. Prototype units for quench detection, temperature and voltage measurement have been successfully tested. Six temperature measurement units are already in use in the KIT test facility TOSKA and operated reliably during the acceptance tests of the HTS current leads for Wendelstein 7-X (W7-X) in 2011/2012. CuLTKa will be used first for 26 current leads which will be built in KIT for the fusion experiment JT-60SA. The present paper gives an overview of the design of the electronic measurement and quench detection equipment

  12. Non-destructive measurement methods for large scale gaseous diffusion process equipment

    International Nuclear Information System (INIS)

    Mayer, R.L.; Hagenauer, R.C.; McGinnis, B.R.

    1994-01-01

    Two measurement methods have been developed to measure non-destructively uranium hold-up in gaseous diffusion plants. These methods include passive neutron and passive γ ray measurements. An additional method, high resolution γ ray spectroscopy, provides supplementary information about additional γ ray emitting isotopes, γ ray correction factors, 235 U/ 234 U ratios and 235 U enrichment. Many of these methods can be used as a general purpose measurement technique for large containers of uranium. Measurement applications for these methods include uranium hold-up, waste measurements, criticality safety and nuclear accountability

  13. Universal Robot Hand Equipped with Tactile and Joint Torque Sensors: Development and Experiments on Stiffness Control and Object Recognition

    Directory of Open Access Journals (Sweden)

    Hiroyuki NAKAMOTO

    2007-04-01

    Full Text Available Various humanoid robots have been developed and multifunction robot hands which are able to attach those robots like human hand is needed. But a useful robot hand has not been depeveloped, because there are a lot of problems such as control method of many degrees of freedom and processing method of enormous sensor outputs. Realizing such robot hand, we have developed five-finger robot hand. In this paper, the detailed structure of developed robot hand is described. The robot hand we developed has five fingers of multi-joint that is equipped with joint torque sensors and tactile sensors. We report experimental results of a stiffness control with the developed robot hand. Those results show that it is possible to change the stiffness of joints. Moreover we propose an object recognition method with the tactile sensor. The validity of that method is assured by experimental results.

  14. Greenhouse gas options, policy and measures for the Canadian Transportation Equipment Manufacturing Industry - Final report

    International Nuclear Information System (INIS)

    2000-02-01

    This report summarizes and analyses the work that have been carried out by the Transportation Equipment Manufacturing Sector (TEMS) Working Group of the National Climate Change Industry Table over the last 14 months, and presents the Group's view of appropriate policies for greenhouse gas emission reduction in Canada. To develop its approach, the Working Group conducted five separate studies which are included in this report as annexes. Annex A is a Foundation Paper, which provides an overview of the sector's performance vis-a-vis energy use and greenhouse gas production. Annex B analyzes the competitive position of the industry by reviewing growth trends in each of the industry sub-sectors and the key factors in maintaining and enhancing the sector's international competitive position. Annex C is a technology assessment. It provides an overview of the uptake of energy saving technology in the sector. Annex D provides a facility level analysis focusing on energy use in the automotive parts manufacturing sector. Annex E is a review of American policies on climate change, summarizing the approach currently being taken towards greenhouse gas emission reduction in the United States. Some of the key findings of this report are: (1) business-as-usual emissions will greatly exceed the implicit Kyoto target of six per cent reduction from 1990 levels, (2) relatively few opportunities exist for major emissions reductions through the use of existing technology, (3) sector-specific policies appear to be ill-advised, but cross-cutting policies provide good opportunities for the transportation equipment manufacturing sector to do its part in helping Canada meeting its Kyoto commitment. The report recommends investigation of barriers to adoption of new technologies and examination of market imperfections, promotion of cogeneration where it makes economic sense, and consideration of the use of flexible instruments such as carbon taxes and tradable emission permits. Overall, the

  15. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    International Nuclear Information System (INIS)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design

  16. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design.

  17. Performance measurement using overall equipment effectiveness (OEE): Literature review and practical application discussion

    OpenAIRE

    Pintelon , Liliane M-Y A; Muchiri , Peter Nganga

    2008-01-01

    Abstract The quest for improving productivity in the current global competitive environment has led to a need for a rigorously defined performance measurement systems for manufacturing processes. In this paper, OEE is described as such kind of performance measurement tool that measures different types of production losses and indicates areas of process improvement. Analysis is done on how OEE has evolved leading to other tools like TEEP, PEE, OFE, OPE and OAE. Two industrial exampl...

  18. Meteorological measurements performed at the Saclay Centre of Nuclear Studies, and used equipment

    International Nuclear Information System (INIS)

    Levrard, A.

    1960-01-01

    This note first recalls the objective of meteorological measurements performed at the CENS station atmospheric radioactivity control station. It briefly recalls some definitions and notions in meteorology: atmosphere vertical structure, atmospheric humidity, atmospheric pressure, weather fronts and passage of disturbances, cloud systems. It indicates measurements performed on a daily basis (temperature in the shelter, minimum and maximum temperature, relative humidity, dew point temperature, atmospheric pressure, soil condition, present weather, visibility, past weather, cloudiness, precipitations, miscellaneous phenomena), recorded measurements (wind strength and direction, atmospheric pressure, relative humidity, temperature, pluviometry), while indicating and presenting corresponding measurement devices

  19. Pilot study of methods and equipment for in-home noise level measurements.

    Science.gov (United States)

    Neitzel, Richard L; Heikkinen, Maire S A; Williams, Christopher C; Viet, Susan Marie; Dellarco, Michael

    2015-01-15

    Knowledge of the auditory and non-auditory effects of noise has increased dramatically over the past decade, but indoor noise exposure measurement methods have not advanced appreciably, despite the introduction of applicable new technologies. This study evaluated various conventional and smart devices for exposure assessment in the National Children's Study. Three devices were tested: a sound level meter (SLM), a dosimeter, and a smart device with a noise measurement application installed. Instrument performance was evaluated in a series of semi-controlled tests in office environments over 96-hour periods, followed by measurements made continuously in two rooms (a child's bedroom and a most used room) in nine participating homes over a 7-day period with subsequent computation of a range of noise metrics. The SLMs and dosimeters yielded similar A-weighted average noise levels. Levels measured by the smart devices often differed substantially (showing both positive and negative bias, depending on the metric) from those measured via SLM and dosimeter, and demonstrated attenuation in some frequency bands in spectral analysis compared to SLM results. Virtually all measurements exceeded the Environmental Protection Agency's 45 dBA day-night limit for indoor residential exposures. The measurement protocol developed here can be employed in homes, demonstrates the possibility of measuring long-term noise exposures in homes with technologies beyond traditional SLMs, and highlights potential pitfalls associated with measurements made by smart devices.

  20. Measuring University Students' Perceived Self-Efficacy in Science Communication in Middle and High Schools

    Science.gov (United States)

    Chi, Shaohui; Liu, Xiufeng; Gardella, Joseph A.

    2016-01-01

    Service learning typically involves university students in teaching and learning activities for middle and high school students, however, measurement of university students' self-efficacy in science communication is still lacking. In this study, an instrument to measure university students' perceived self-efficacy in communicating science to…

  1. Home built equipment for measuring Hall coefficient and charge carrier concentration, mobility and resistivity

    DEFF Research Database (Denmark)

    Borup, Kasper Andersen; Christensen, Mogens; Blichfeld, Anders Bank

    2011-01-01

    der Pauw method. The commercial availability of these systems is limited and they are usually not optimized for measurements on samples which show properties characteristic of thermoelectric materials. We give an assessment of the reliability of the measurements and a comparison with a commercial...

  2. EMC of harmonic and transient measurement equipment in offshore wind farms

    DEFF Research Database (Denmark)

    Kocewiak, Łukasz Hubert; Arana Aristi, Iván; Hjerrild, Jesper

    2012-01-01

    The electromagnetic compatibility (EMC) and interference (EMI) challenges during the development, construction, testing and installation of a measurement system for multi-point, high-speed and long-term data logging is described in this paper. The presented measurement system was tested in a rough...

  3. Measurement of scattered and transmitted X-rays from intra-oral and panoramic dental X-ray equipment.

    Science.gov (United States)

    Holroyd, John Richard

    2018-04-10

    To quantify the levels of transmitted radiation arising from the use of intra-oral dental X-ray equipment and scattered radiation arising from the use of both intra-oral and panoramic X-ray equipment. Methods: Levels of scattered radiation were measured at 1 m from a phantom, using an 1800 cc ion chamber. Transmitted radiation was measured using both: i) a phantom and Dose Area Product (DAP) meter, ii) a patient and an 1800 cc ion chamber. Results: For intra-oral radiography the patient study gave a maximum transmission of 1.80% (range 0.04% to 1.80%, mean 0.26%) and the phantom study gave a maximum transmission of 6% (range 2% to 6%, mean 5%). The maximum scattered radiation, per unit DAP, was 5.5 nGy (mGy cm2)-1 at 70 kVp and a distance of 1 m. For panoramic radiography the maximum scattered radiation was 9.3 nGy (mGy cm2)-1 at 80 kVp and a distance of 1 m. Conclusions: Typical doses from scattered and transmitted radiation in modern dental practice have been measured and values are presented to enable the calculation of adequate protection measures for dental radiography rooms. Advances in knowledge: Previous studies have used a phantom and measured radiation doses at 1 m from the phantom to determine the radiation dose transmitted through a patient, whereas this study uses both patient and phantom measurements together with a large area dose meter, positioned to capture the entire X-ray beam, to ensure more realistic dose measurements can be made. © 2018 IOP Publishing Ltd.

  4. Measuring recent research performance for Chinese universities using bibliometric methods

    KAUST Repository

    Zhu, Jia; Hassan, Saeed-Ul; Mirza, Hamid Turab; Xie, Qing

    2014-01-01

    from their published work. We also find that the Chinese universities have relative low percentage of publications at high impact venues, which may be the reason that they are not receiving more citations. Therefore, a careful selection of publication

  5. Calibration of an inertial-magnetic measurement unit without external equipment, in the presence of dynamic magnetic disturbances

    International Nuclear Information System (INIS)

    Metge, J; Giremus, A; Mégret, R; Berthoumieu, Y; Décamps, T

    2014-01-01

    Inertial-magnetic measurement units are inexpensive sensors, widely used in electronic systems (smartphones, GPS, micro-UAV, etc). However the precision of these sensors is highly dependent on their calibration. This article proposes a complete solution to calibrate the sensors (accelerometers, gyrometers and magnetometers), the inter-sensor rotations and the dynamic disturbances of the magnetic field due to the immediate environment. Contrary to most of the existing techniques, the proposed method does not necessitate any external equipment, apart from the sensors already included in the system. The calibration can be performed by hand manipulation by the final user. Simulations and experiments show the advantages of the proposed approach. (paper)

  6. Measuring organizational learning. Model testing in two Romanian universities

    OpenAIRE

    Alexandra Luciana Guţă

    2014-01-01

    The scientific literature associates organizational learning with superior organization performance. If we refer to the academic environment, we appreciate that it can develop and reach better levels of performance through changes driven from the inside. Thus, through this paper we elaborate on a conceptual model of organizational learning and we test the model on a sample of employees (university teachers and researchers) from two Romanian universities. The model comprises the process of org...

  7. A study regarding measurements of bacterial contamination levels in radiology room equipment

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Eun Jin [Dept. of Public Health and Medicine, Dongshin University Graduate School, Naju (Korea, Republic of); Song, Hyeon Je [Dept. of Clinical Pathology, Gwangju Health University, Gwangju (Korea, Republic of); Dong, Kyung Rae; Kim, Chang Bok [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Ryu, Jae Kwang [Dept. of Nuclear Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-03-15

    Reported some level of bacteria in areas that are well made contact in Radiology imaging room evaluate the importance of cleanliness in the hospital management of equipment to check for the presence of pathogenic bacteria. Gwang-ju and Jeol-la city and medium-sized hospitals in the material with a cotton swab and rub evenly Radiology selection cassette, a handle, Apron of the imaging apparatus having the most contact with patients from July 2016 to August 2016 as a target in place and special studios 6, and saline solution will placed in a test tube containing. The swab sample was diluted 1,000 times, you can see the bacteria and the intestinal bacterial selective medium Trypticase Soy Agar (TSA), Muller-Hinton Agar (MHA), EosinMethylene Blue (EMB), ENDO (BD, NJ, USA) then incubated smear to. In the incubator (incubator, SANYO, Japan) was observed after incubation of bacteria and counting the total number of bacteria also Colonies (colony) suspected intestinal bacteria were isolated and cultured on KIA medium (BD, NJ, USA). As a result, it was found that this came Gram positive Coccus A hospital handle the F hospital, from the C Gram positive Coccus cassette and handle the F hospital. The striking yellow coloring Staphylococcus aureus 110 agar (STA 110) in the medium sample, but it is suspected staphylococcal Coccus to the final identifcation in the laboratory is not a single specimen of the two samples from Gram positive Coccus biochemical identifcation. Identifcation Kit is an API could not, it was thought to be non-Staphylococcus aureus was cultured on blood agar suggesting that (BAP) blood of dance. Dynamic tests were conducted biochemical API kit of the two samples were identifed from Gram positive Coccus bacteria Escherichia coli (E. coli) is F hospital cassette was confrmed Eenterobacter cloaca in A hospital possession. Did not aggregate O-26, O-111, O-157 and the serum test was conducted in the laboratory from the E. coli F cassette hospital.

  8. A study regarding measurements of bacterial contamination levels in radiology room equipment

    International Nuclear Information System (INIS)

    Choi, Eun Jin; Song, Hyeon Je; Dong, Kyung Rae; Kim, Chang Bok; Ryu, Jae Kwang

    2017-01-01

    Reported some level of bacteria in areas that are well made contact in Radiology imaging room evaluate the importance of cleanliness in the hospital management of equipment to check for the presence of pathogenic bacteria. Gwang-ju and Jeol-la city and medium-sized hospitals in the material with a cotton swab and rub evenly Radiology selection cassette, a handle, Apron of the imaging apparatus having the most contact with patients from July 2016 to August 2016 as a target in place and special studios 6, and saline solution will placed in a test tube containing. The swab sample was diluted 1,000 times, you can see the bacteria and the intestinal bacterial selective medium Trypticase Soy Agar (TSA), Muller-Hinton Agar (MHA), EosinMethylene Blue (EMB), ENDO (BD, NJ, USA) then incubated smear to. In the incubator (incubator, SANYO, Japan) was observed after incubation of bacteria and counting the total number of bacteria also Colonies (colony) suspected intestinal bacteria were isolated and cultured on KIA medium (BD, NJ, USA). As a result, it was found that this came Gram positive Coccus A hospital handle the F hospital, from the C Gram positive Coccus cassette and handle the F hospital. The striking yellow coloring Staphylococcus aureus 110 agar (STA 110) in the medium sample, but it is suspected staphylococcal Coccus to the final identifcation in the laboratory is not a single specimen of the two samples from Gram positive Coccus biochemical identifcation. Identifcation Kit is an API could not, it was thought to be non-Staphylococcus aureus was cultured on blood agar suggesting that (BAP) blood of dance. Dynamic tests were conducted biochemical API kit of the two samples were identifed from Gram positive Coccus bacteria Escherichia coli (E. coli) is F hospital cassette was confrmed Eenterobacter cloaca in A hospital possession. Did not aggregate O-26, O-111, O-157 and the serum test was conducted in the laboratory from the E. coli F cassette hospital

  9. GPS Synchronization and EMC of Harmonic and Transient Measurement Equipment in Offshore Wind Farms

    DEFF Research Database (Denmark)

    Kocewiak, Łukasz Hubert; Arana, Iván; Hjerrild, Jesper

    2012-01-01

    synchronization, electromagnetic compatibility (EMC) and interference (EMI) challenges during the development, construction, testing and installation of a measurement system for multi-point, high-speed and long-term data logging is described in this paper. The presented measurement system was tested in a rough...... offshore environment at Avedøre Holme and Gunfleet Sands offshore wind farms.The paper will describe the application of GPS technology in synchronised measurements carried out at Avedøre Holme and Gunfleet Sands wind farms. Different aspects of software development and hardware configuration in order...

  10. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  11. The high voltage divider - a tool for comparison of measurement equipment in diagnostic radiology

    International Nuclear Information System (INIS)

    Slavchev, A.; Litchev, A.; Constantinov, B.

    2004-01-01

    The high voltage divider (HVD) is designed for control and analysis of the characteristics of the X-ray generator. The low voltage analogous signals produced by the divider are proportional to the high voltage (kVp) applied to the x-ray tube by a ratio 1:1000 or 1:10000 and can be measured with external test devices like storage oscilloscope (or digital multimeter). The exposure duration and the wave form may be visualized, too. Apart of this invasive way the high voltage also may be measured non-invasively by means of appropriate devices as well as indirectly through calculations. Since the invasive method of measurement with the high voltage divider is distinguished by a high accuracy, it may be utilized as an effective tool for calibration of different devices and for comparison of the measurement methods. (authors)

  12. Methodology of ionizing radiation measurement, from x-ray equipment, for radiation protection

    International Nuclear Information System (INIS)

    Caballero, Katia C.S.; Borges, Jose C.

    1996-01-01

    Most of X-rays beam used for diagnostic, are short exposure time (milliseconds). Exception are those used in fluoroscopy. measuring instruments (area monitors with ionizing chambers or Geiger tubes) used in hospitals and clinics, in general, have characteristic answer time not adequate to X-rays beams length in time. Our objective was to analyse instruments available commercially, to prepare a measuring methodology for direct and secondary beams, in order to evaluate protection barriers for beams used in diagnostic radiology installations. (author)

  13. Mobile equipment for measurement of gamma radiation; Mobilt maaleutstyr for maaling av gammastraaling

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-01

    NRPA has several systems to perform mobile measurements. One of the systems consists of detectors mounted on the roof of a car. Mobile systems can be used to map the radioactive contamination of large areas in a short time, to the reference measurements and to search for sources astray. The systems can be mounted on the vehicle or used in a helicopter or airplane. (AG)

  14. Methodology and measures for preventing unacceptable flow-accelerated corrosion thinning of pipelines and equipment of NPP power generating units

    Science.gov (United States)

    Tomarov, G. V.; Shipkov, A. A.; Lovchev, V. N.; Gutsev, D. F.

    2016-10-01

    Problems of metal flow-accelerated corrosion (FAC) in the pipelines and equipment of the condensate- feeding and wet-steam paths of NPP power-generating units (PGU) are examined. Goals, objectives, and main principles of the methodology for the implementation of an integrated program of AO Concern Rosenergoatom for the prevention of unacceptable FAC thinning and for increasing operational flow-accelerated corrosion resistance of NPP EaP are worded (further the Program). A role is determined and potentialities are shown for the use of Russian software packages in the evaluation and prediction of FAC rate upon solving practical problems for the timely detection of unacceptable FAC thinning in the elements of pipelines and equipment (EaP) of the secondary circuit of NPP PGU. Information is given concerning the structure, properties, and functions of the software systems for plant personnel support in the monitoring and planning of the inservice inspection of FAC thinning elements of pipelines and equipment of the secondary circuit of NPP PGUs, which are created and implemented at some Russian NPPs equipped with VVER-1000, VVER-440, and BN-600 reactors. It is noted that one of the most important practical results of software packages for supporting NPP personnel concerning the issue of flow-accelerated corrosion consists in revealing elements under a hazard of intense local FAC thinning. Examples are given for successful practice at some Russian NPP concerning the use of software systems for supporting the personnel in early detection of secondary-circuit pipeline elements with FAC thinning close to an unacceptable level. Intermediate results of working on the Program are presented and new tasks set in 2012 as a part of the updated program are denoted. The prospects of the developed methods and tools in the scope of the Program measures at the stages of design and construction of NPP PGU are discussed. The main directions of the work on solving the problems of flow

  15. Measuring the Efficiency of Public Universities: Using Data Envelopment Analysis (DEA) to Examine Public Universities in Saudi Arabia

    Science.gov (United States)

    Alabdulmenem, Fahad Mohammed

    2017-01-01

    Saudi Arabia is one of the countries that allot substantial amount of government resources for education. Thus, it is important to measure how these resources are used to generate favorable academic outcomes for its nationals. In this study, data envelopment analysis (DEA) is used to measure the relative efficiency of 25 public universities in…

  16. Development of the automatic measuring system to survey the surface contamination on equipments

    International Nuclear Information System (INIS)

    Ishizuka, Akira; Matsumura, Hidekatsu; Nawa, Takao; Yamaguchi, Seiji; Yamada, Tadashi.

    1980-01-01

    The inspection of surface contamination carried out when things are taken out of the control areas in nuclear power stations requires considerable labor and time because it is carried out manually. In order to make the inspection of surface contamination more efficiently and to standardize it, the development of an automatic inspection apparatus was carried out. This apparatus inspects the surface contamination due to radio isotopes which do not emit α-ray, and the objects to be measured are the large things with definite forms, such as boards and pipes for scaffolding. The method of measuring β-ray with a gas flow counter was adopted for the apparatus in view of the good detection sensitivity, relatively simple shielding against background, and easy conversion to surface contamination density. The measuring system was composed of the gas flow counters and a rate meter. The outline of the apparatus made for trial is explained. As the result of the performance test, the lowest detection sensitivity was 1.29 x 10 -5 μCi/cm 2 at the moving speed of an object of 1 cm/sec. The detection sensitivity is improved by the flattening of the sensitivity distribution. The evaluation of the error, the reduction of measuring time and the prevention of contamination were also made. (Kako, I.)

  17. Analysis of the results obtained by optical measurements in plasma focus equipments

    International Nuclear Information System (INIS)

    Bilbao, L.; Bruzzone, H.

    1982-01-01

    The results obtained by shadow and Schlieren photographies and interferometry in a 1MJ plasma focus device of Frascati (CNEN-EURATOM, Italy) are compared with a great number of similar measurement results in several devices of the world. A critical analysis of the above results is presented. (L.C.) [pt

  18. The Coincidence Tracker: Electronic Equipment for a Time-of-Flight Wind-Speed Measurement System

    DEFF Research Database (Denmark)

    Fog, Christian

    1982-01-01

    The electronic part of a laser-beam measuring system for wind velocity is described. Pulses of light scattered from aerosols are treated, first in a pair of adaptive filters, then in a tracker that calculates the wind velocity on-line while applying some knowledge about the velocity to be expected...

  19. Force Measurement Services at Kebs: AN Overview of Equipment, Procedures and Uncertainty

    Science.gov (United States)

    Bangi, J. O.; Maranga, S. M.; Nganga, S. P.; Mutuli, S. M.

    This paper describes the facilities, instrumentation and procedures currently used in the force laboratory at the Kenya Bureau of Standards (KEBS) for force measurement services. The laboratory uses the Force Calibration Machine (FCM) to calibrate force-measuring instruments. The FCM derives its traceability via comparisons using reference transfer force transducers calibrated by the Force Standard Machines (FSM) of a National Metrology Institute (NMI). The force laboratory is accredited to ISO/IEC 17025 by the Germany Accreditation Body (DAkkS). The accredited measurement scope of the laboratory is 1 MN to calibrate force transducers in both compression and tension modes. ISO 376 procedures are used while calibrating force transducers. The KEBS reference transfer standards have capacities of 10, 50, 300 and 1000 kN to cover the full range of the FCM. The uncertainty in the forces measured by the FCM were reviewed and determined in accordance to the new EURAMET calibration guide. The relative expanded uncertainty of force W realized by FCM was evaluated in a range from 10 kN-1 MN, and was found to be 5.0 × 10-4 with the coverage factor k being equal to 2. The overall normalized error (En) of the comparison results was also found to be less than 1. The accredited Calibration and Measurement Capability (CMC) of the KEBS force laboratory was based on the results of those intercomparisons. The FCM enables KEBS to provide traceability for the calibration of class ‘1’ force instruments as per the ISO 376.

  20. Measurement of adhesion properties between topcoat paint and metallized/galvanized steel with surface energy measurement equipment.

    Science.gov (United States)

    2013-09-01

    The objectives of this research project are: (1) Compare the adhesion properties of NEPCOAT-approved topcoat paint over : metallized or galvanized steel. Use surface-energy measuring technique to characterize the wetting properties of the liqui...

  1. Measuring Ucrit and endurance: equipment choice influences estimates of fish swimming performance.

    Science.gov (United States)

    Kern, P; Cramp, R L; Gordos, M A; Watson, J R; Franklin, C E

    2018-01-01

    This study compared the critical swimming speed (U crit ) and endurance performance of three Australian freshwater fish species in different swim-test apparatus. Estimates of U crit measured in a large recirculating flume were greater for all species compared with estimates from a smaller model of the same recirculating flume. Large differences were also observed for estimates of endurance swimming performance between these recirculating flumes and a free-surface swim tunnel. Differences in estimates of performance may be attributable to variation in flow conditions within different types of swim chambers. Variation in estimates of swimming performance between different types of flumes complicates the application of laboratory-based measures to the design of fish passage infrastructure. © 2017 The Fisheries Society of the British Isles.

  2. Project ARINUS: 2. establishment of the measuring equipment and testing phase

    Energy Technology Data Exchange (ETDEWEB)

    Feger, K.H.; Zoettl, H.W.; Brahmer, G.; Horsch, F.; Filby, W.G.; Fund, N.; Gross, S.; Hanisch, B.; Kilz, E.; Seidel, A.

    1988-04-01

    In 3 adjacent watersheds water and element fluxes are determined by measuring open land precipitation, canopy throughfall, litterfail, and soil seepage water at 3 depths. Cation-anion-balances of the first half-year of measurement demonstrate a distinct chemical alteration of precipitation passing through the bio-, pedo- and lithosphere. Precipitation shows only a slight to moderate impact of air pollution. Dissolved organic matter highly influences the pH-values and the mobility of potentially toxic aluminum. A simplified Al-fractionation exhibits a high portion of nontoxic organic complexes. The composition of seepage water in the upper soil is mainly controlled by biological processes is plant uptake, mineralization and microbial immobilization. Adsorption and weathering processes in the subsoil and bedrock play the key roles in SO/sub 4//sup 2-/ retention and buffering of acids.

  3. System for connection of a scanning measuring equipment with a computer

    International Nuclear Information System (INIS)

    Avdeev, N.F.; Bogomolov, M.N.; Volkov, G.A.

    1976-01-01

    A system of communication of viewing and measuring devices is considered ensuring an on-line operation with BESM-4 computer. A program of film data processing is presented. A detailed description is given with respect to an interface. Modifications are mentioned in some units of the semi-automatic devices which ensure a communication with a computer. The communication system allows for a man-machine dialogue

  4. Monitoring and measurement of variables - assurance of observability and controllability of the reactor equipment

    International Nuclear Information System (INIS)

    Durnev, V.N.; Mitelman, M.G.

    2001-01-01

    The presentation presents main conclusions on the basis of analysis of the existing situation with assurance of observability and controllability of the reactor installation. A methodology of classification of variables of the controlled object state and proposals on selection and substantiation of measurement and inspection monitoring techniques is given. Main problems associated with assurance of observability and controllability of the reactor installation are presented for various operation modes. (Authors)

  5. Contractors Road Heavy Equipment Area SWMU 055 Corrective Measures Implementation Progress Report Kennedy Space Center, Florida

    Science.gov (United States)

    Johnson, Jill W. (Compiler)

    2015-01-01

    This Corrective Measures Implementation (CMI) Progress Report documents: (i) activities conducted as part of supplemental assessment activities completed from June 2009 through November 2014; (ii) Engineering Evaluation (EE) Advanced Data Packages (ADPs); and (iii) recommendations for future activities related to corrective measures at the Site. Applicable meeting minutes are provided as Appendix A. The following EE ADPs for CRHE are included with this CMI Progress Report: center dot Supplemental Site Characterization ADP (Step 1 EE) (Appendix B) center dot Site Characterization ADP (Step 1 EE) for Hot Spot 1 (HS1) (Appendix C) center dot Remedial Alternatives Evaluation (Step 2 EE) ADP for HS1 (Appendix D) center dot Interim Measures Work Plan (Step 3 EE) ADP for HS1 (Appendix E) center dot Site Characterization ADP (Step 1 EE) ADP for Hot Spot 2 (HS2), High Concentration Plume (HCP), and Low Concentration Plume (LCP) (Appendix F) A summary of direct-push technology (DPT) and groundwater monitoring well sampling results are provided in Appendices G and H, respectively. The Interim Land Use Control Implementation Plan (LUCIP) is provided as Appendix I. Monitoring well completion reports, other applicable field forms, survey data, and analytical laboratory reports are provided as Appendices J through M, respectively, in the electronic copy of this document. Selected Site photographs are provided in Appendix N. The interim groundwater monitoring plan and document revision log are included as Appendices O and P, respectively. KSC Electronic Data Deliverable (KEDD) files are provided on the attached compact disk.

  6. Measuring E-Learning Effectiveness at Indonesian Private University

    Science.gov (United States)

    Pradana, Mahir; Amir, NarisWari

    2016-01-01

    Telkom University was founded in 2013, as a result of merging four existing higher education institutions in Indonesia. One of their study programs is Master of Management (MM) program, which also facilitates full-time workers to participate in the program. Since their physical presences are sometimes unfulfilled, an e-learning program was…

  7. Measuring Progress toward Universal Primary Education: An Examination of Indicators

    Science.gov (United States)

    Langsten, Ray

    2014-01-01

    The Education Millennium Development Goal of universal primary education (UPE) states that "by 2015, children everywhere, boys and girls alike, will be able to complete a full course of primary schooling." The 2008 midterm Global Monitoring Report claims that "A country's distance from UPE appears most clearly in terms of the net…

  8. Visualization of elongation measurements using an SER universal testing platform

    Czech Academy of Sciences Publication Activity Database

    Pivokonský, Radek; Filip, Petr; Zelenková, Jana

    2015-01-01

    Roč. 25, č. 1 (2015), s. 1-8 ISSN 1430-6395 R&D Projects: GA ČR(CZ) GAP105/11/2342 Institutional support: RVO:67985874 Keywords : elongational viscosity * Universal Testing Platform (SER) * polymer melts * LDPE Subject RIV: BK - Fluid Dynamics Impact factor: 1.241, year: 2015

  9. Is the Environmental Literacy of University Students Measurable?

    Science.gov (United States)

    Shephard, Kerry; Harraway, John; Lovelock, Brent; Skeaff, Sheila; Slooten, Liz; Strack, Mick; Furnari, Mary; Jowett, Tim

    2014-01-01

    We report the development and piloting of an evaluative instrument and process for monitoring the environmental literacy (EL) of undergraduate students in one large research-led university in New Zealand. The instrument addresses knowledge, affect and competencies in the general area of EL in line with this institution's adoption of EL as a…

  10. Development of an equipment for the detection and measurement of localized corrosion of carbon steel induced by sulfidogenic bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Cotiche, C. [CFG Services, 3 avenue Claude Guillemin, BP 6429, 45064 Orleans Cedex (France); Dauma, S. [CFG Services, 117 avenue de Luminy, 13009 Marseille (France)

    2004-07-01

    Most of the geothermal installations exploiting the Dogger aquifer of the Paris basin are faced to corrosion and scaling problems. Localized corrosion phenomena due to the presence of sulfate reducing bacteria which have been identified in the geothermal water and in scales deposited on corrosion coupons is the most insidious being able to induce rapid failures of the casings of production and injection wells and surface pipelines. In order to evaluate and prevent the occurrence of such corrosion risks that are similar to those encountered in oil and gas industry, a specific equipment has been developed by CFG Services, engineering company specialized in the exploitation and maintenance of geothermal plants. This equipment which includes a probe and an electronic device has to be installed on the pipeline transporting the corrosive medium through a nipple secured to it. The principle is based on the generation of a pit on a circular electrode in carbon steel by anodic polarization and on the measurement of the corrosion current between this electrode and the pipeline or the probe body used as cathodic pole. Then, the current freely flowing between the anode and cathode is monitored and used to estimate if the pitting corrosion artificially created by an electric pulse may be maintained or not by the activity of sulfidogenic bacteria which may have developed on the surface of the electrode. This equipment has been tested on a geothermal exploitation where the risk of microbial corrosion has been identified and the sensibility of the signal of the probe to the injection of biocide products proved. (authors)

  11. Use of REMPI-TOFMS for real-time measurement of trace aromatics during operation of aircraft ground equipment

    Science.gov (United States)

    Gullett, Brian; Touati, Abderrahmane; Oudejans, Lukas

    Emissions of aromatic air toxics from aircraft ground equipment (AGE) were measured with a resonance enhanced multiphoton ionization-time of flight mass spectrometry (REMPI-TOFMS) system consisting of a pulsed solid state laser for photoionization and a TOFMS for mass discrimination. This instrument was capable of characterizing turbine emissions and the effect of varying load operations on pollutant production. REMPI-TOFMS is capable of high selectivity and low detection limits (part per trillion to part per billion) in real time (1 s resolution). Hazardous air pollutants and criteria pollutants were measured during startups and idle and full load operations. Measurements of compounds such as benzene, toluene, ethylbenzene, xylenes, styrene, and polycyclic aromatic hydrocarbons compared well with standard methods. Startup emissions from the AGE data showed persistent concentrations of pollutants, unlike those from a diesel generator, where a sharp spike in emissions rapidly declined to steady state levels. The time-resolved responses of air toxics concentrations varied significantly by source, complicating efforts to minimize these emissions with common operating prescriptions. The time-resolved measurements showed that pollutant concentrations decline (up to 5×) in a species-specific manner over the course of multiple hours of operation, complicating determination of accurate and precise emission factors via standard extractive sampling. Correlations of air toxic concentrations with more commonly measured pollutants such as CO or PM were poor due to the relatively greater changes in the measured toxics' concentrations.

  12. Some problems related to the development of data bank for nuclear measuring equipment

    International Nuclear Information System (INIS)

    Bialkovski, T.; Krushevski, K.G.

    1984-01-01

    On the basis of INFOL information language using the CYBER- 73-14 computer the data base of ionizing radiation detectors is developed. The data base accumulates information on parameters of ionization chambers, proportional counters, Geiger-Mueller counters, scintillation counters and semiconductor detectors. The data are subdivided into the following groups: data of general type, documents, technical parameters, reserve for technical parameters and conditions for technical parameter measurements. Four data groups comprise technical parameters: main, mechanical, electric and material ones. The INFOL language permits to create approximately 300 fields

  13. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    Science.gov (United States)

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  14. Transcutaneous oximetry measurements of the leg: comparing different measuring equipment and establishing values in healthy young adults.

    Science.gov (United States)

    Trinks, Tobias P; Blake, Denise F; Young, Derelle A; Thistlethwaite, Ken; Vangaveti, Venkat N

    2017-06-01

    Transcutaneous oximetry measurement (TCOM) is a non-invasive method of determining oxygen tension at the skin level using heated electrodes. To compare TCOM values generated by different machines and to establish lower limb TCOM values in a cohort of healthy individuals younger than 40 years of age. Sixteen healthy, non-smoking volunteers aged 18 to 39 years were recruited. TCOM was obtained at six locations on the lower leg and foot using three different Radiometer machines. Measurements were taken with subjects lying supine, breathing air. Except for one sensor site, there were no statistical differences in measurements obtained by the different TCOM machines. There was no statistical difference in measurements comparing left and right legs. Room air TCOM values for the different lower leg sites were (mean (SD) in mmHg): lateral leg 61.5 (9.2); lateral ankle 61.1 (9.7); medial ankle 59.1 (10.8); foot, first and second toe 63.4 (10.6); foot, fifth toe 59.9 (13.2) and plantar foot 74.1 (8.8). The overall mean TCOM value for the lower limb was 61 (10.8; 95% confidence intervals 60.05-62.0) mmHg. Lower-leg TCOM measurements using different Radiometer TCOM machines were comparable. Hypoxia has been defined as lower-leg TCOM values of less than 40 mmHg in non-diabetic patients and this is supported by our measurements. The majority (96.9%) of the lower leg TCOM values in healthy young adults are above the hypoxic threshold.

  15. Measuring equipment and regulation of gas consuming appliances. Requirements for measuring equipments and regulation of gas consuming appliances; Maeleudstyr og indregulering af gasforbrugende apparater. Krav til maeleudstyr og indregulering af gasforbrugende apparater. Projektrapport

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, H.

    2004-06-01

    Regulation of gas consuming appliances has so far been regarded as a banality. However, during recent years a number of misunderstandings have arisen in this area. The load to which a gas consuming appliance should be regulated under practical conditions is often unclear. By way of example may be mentioned that the factory typically set the load using G20 reference gas (pure methane). Under practical Danish conditions the load (with Danish natural gas) is approx. 2% higher than the load set from the factory. This report focuses on the problems with varying gas composition in relation to regulation of gas consuming appliances. Furthermore, a number of unclear points concerning measuring equipment are dealt with. The report aims at offering suggestions for practical solutions. (BA)

  16. Equipment for automatic measurement of gamma activity distribution in a column

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Vilcek, S.; Balkovsky, K.

    1978-01-01

    The design of a device for stepwise scanning of gamma activity distributions along chromatographic columns is described. In connection with a single-channel gamma spectrometer and a counting ratemeter with a recorder this device permits the resolution of a number of gamma emitters on the column, the determination of the gamma nuclide content in different chemical forms in the sample by means of column separation methods - Gel Chromatography Columns Scanning Method - and the determination of gamma nuclide distribution along the columns. The device permits the scanning of columns of up to 20 mm in diameter and 700 mm in length and continual scanning over a 450 mm column length with one clamping. With minor adaptations it is possible to scan columns up to 30 mm in diameter. The length of the scanned sections is 5 or 10 mm, the scanning time setting is arbitrary and variable activity levels and radiation energies may be measured. (author)

  17. Standard Measurement & Verification Plan for Lighting Equipment Retrofit or Replacement Projects

    Energy Technology Data Exchange (ETDEWEB)

    Richman, Eric E.

    2009-11-04

    This document provides a framework for a standard Measurement and Verification (M&V) plan for lighting projects. It was developed to support cost-effective retrofits (partial and complete replacements) of lighting systems and is intended to provide a foundation for an M&V plan for a lighting retrofit utilizing a "best practice" approach, and to provide guidance to site owners, contractors, and other involved organizations on what is essential for a robust M&V plan for lighting projects. This document provides examples of appropriate elements of an M&V plan, including the calculation of expected energy savings. The standard M&V plan, as provided, also allows for consistent comparison with other similar lighting projects. Although intended for lighting retrofit applications, M&V plans developed per this framework document may also be used for other non-lighting technology retrofits and new installations.

  18. Responses of sun-induced chlorophyll fluorescence to biological and environmental variations measured with a versatile Fluorescence Auto-Measurement Equipment (FAME)

    Science.gov (United States)

    Gu, L.

    2017-12-01

    In this study, we examine responses of sun-induced chlorophyll fluorescence to biological and environmental variations measured with a versatile Fluorescence Auto-Measurement Equipment (FAME). FAME was developed to automatically and continuously measure chlorophyll fluorescence (F) of a leaf, plant or canopy in both laboratory and field environments, excited by either artificial light source or sunlight. FAME is controlled by a datalogger and allows simultaneous measurements of environmental variables complementary to the F signals. A built-in communication system allows FAME to be remotely monitored and data-downloaded. Radiance and irradiance calibrations can be done online. FAME has been applied in a variety of environments, allowing an investigation of biological and environmental controls on F emission.

  19. Research on the Scientific and Technological Innovation of Research University and Its Strategic Measures

    Science.gov (United States)

    Cheng, Yongbo; Ge, Shaowei

    2005-01-01

    This paper illustrates the important role that the scientific and technological innovation plays in the research university. Technological innovation is one of the main functions that the research university serves and contributes for the development of economy and society, which is the essential measure for Research University to promote…

  20. Development and Standardization of Inventory for Measuring Students' Integration into University Academic Culture

    Science.gov (United States)

    Esomonu, Nkechi Patricia-Mary; Okeaba, James Uzoma

    2016-01-01

    The study developed and standardized an Inventory for measuring Students' Integration into University Academic Culture named Inventory for Students' Integration into University Academic Culture (ISIUAC). The increase in dropout rates, substance use, cultism and other deviant behaviours in Nigerian universities makes it necessary for one to ask the…

  1. Mock-up experiment at Birmingham University for BNCT project of Osaka University – Neutron flux measurement with gold foil

    International Nuclear Information System (INIS)

    Tamaki, S.; Sakai, M.; Yoshihashi, S.; Manabe, M.; Zushi, N.; Murata, I.; Hoashi, E.; Kato, I.; Kuri, S.; Oshiro, S.; Nagasaki, M.; Horiike, H.

    2015-01-01

    Mock-up experiment for development of accelerator based neutron source for Osaka University BNCT project was carried out at Birmingham University, UK. In this paper, spatial distribution of neutron flux intensity was evaluated by foil activation method. Validity of the design code system was confirmed by comparing measured gold foil activities with calculations. As a result, it was found that the epi-thermal neutron beam was well collimated by our neutron moderator assembly. Also, the design accuracy was evaluated to have less than 20% error. - Highlights: • Accelerator based neutron source for BNCT is being developed in Osaka University. • Mock-up experiment was carried out at Birmingham University, UK. • Neutronics performance of our assembly was evaluated from gold foil activation. • Gold foil activation was determined by using HPGe detectors. • Validity of the neutronics design code system was confirmed.

  2. Guideline to good practices for control and calibration of measuring and test equipment (M ampersand TE) at DOE nuclear facilities

    International Nuclear Information System (INIS)

    1993-03-01

    The purpose of the Guideline to Good Practices for Control and Calibration of Measuring and Test Equipment (M ampersand TE) at DOE Nuclear Facilities is to provide contractor maintenance organizations with information that may be used for the development and implementation of a rigorously controlled maintenance program directed at controlling and calibrating M ampersand TE used for maintenance tasks at DOE nuclear facilities. This document is intended to be an example guideline for the implementation of DOE Order 4330.4A, Maintenance Management Program, Chapter II, Element 11. DOE contractors should not feel obligated to adopt all parts of this guide. Rather, they should use the information contained herein as a guide for developing an M ampersand TE program applicable to their facility

  3. Redundant and fault-tolerant algorithms for real-time measurement and control systems for weapon equipment.

    Science.gov (United States)

    Li, Dan; Hu, Xiaoguang

    2017-03-01

    Because of the high availability requirements from weapon equipment, an in-depth study has been conducted on the real-time fault-tolerance of the widely applied Compact PCI (CPCI) bus measurement and control system. A redundancy design method that uses heartbeat detection to connect the primary and alternate devices has been developed. To address the low successful execution rate and relatively large waste of time slices in the primary version of the task software, an improved algorithm for real-time fault-tolerant scheduling is proposed based on the Basic Checking available time Elimination idle time (BCE) algorithm, applying a single-neuron self-adaptive proportion sum differential (PSD) controller. The experimental validation results indicate that this system has excellent redundancy and fault-tolerance, and the newly developed method can effectively improve the system availability. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  4. Performance Improvement of Membrane Stress Measurement Equipment through Evaluation of Added Mass of Membrane and Error Correction

    Directory of Open Access Journals (Sweden)

    Sang-Wook Jin

    2017-01-01

    Full Text Available One of the most important issues in keeping membrane structures in stable condition is to maintain the proper stress distribution over the membrane. However, it is difficult to determine the quantitative real stress level in the membrane after the completion of the structure. The stress relaxation phenomenon of the membrane and the fluttering effect due to strong wind or ponding caused by precipitation may cause severe damage to the membrane structure itself. Therefore, it is very important to know the magnitude of the existing stress in membrane structures for their maintenance. The authors have proposed a new method for separately estimating the membrane stress in two different directions using sound waves instead of directly measuring the membrane stress. The new method utilizes the resonance phenomenon of the membrane, which is induced by sound excitations given through an audio speaker. During such experiment, the effect of the surrounding air on the vibrating membrane cannot be overlooked in order to assure high measurement precision. In this paper, an evaluation scheme for the added mass of membrane with the effect of air on the vibrating membrane and the correction of measurement error is discussed. In addition, three types of membrane materials are used in the experiment in order to verify the expandability and accuracy of the membrane measurement equipment.

  5. Application of a universal optic data link for radiation measurements

    International Nuclear Information System (INIS)

    Komatsu, T.; Takada, E.

    2002-01-01

    Optic Data Link (ODL) is a device to convert electric and optic signals to each other, which is used for the field of optical communications. We examined the possibility to apply ODLs to radiation measurements. The effect of ODLs on energy and timing resolution has been investigated. From the results, fundamental applicability of ODLs to radiation measurements has been demonstrated. (author)

  6. Toward a universal, automated facial measurement tool in facial reanimation.

    Science.gov (United States)

    Hadlock, Tessa A; Urban, Luke S

    2012-01-01

    To describe a highly quantitative facial function-measuring tool that yields accurate, objective measures of facial position in significantly less time than existing methods. Facial Assessment by Computer Evaluation (FACE) software was designed for facial analysis. Outputs report the static facial landmark positions and dynamic facial movements relevant in facial reanimation. Fifty individuals underwent facial movement analysis using Photoshop-based measurements and the new software; comparisons of agreement and efficiency were made. Comparisons were made between individuals with normal facial animation and patients with paralysis to gauge sensitivity to abnormal movements. Facial measurements were matched using FACE software and Photoshop-based measures at rest and during expressions. The automated assessments required significantly less time than Photoshop-based assessments.FACE measurements easily revealed differences between individuals with normal facial animation and patients with facial paralysis. FACE software produces accurate measurements of facial landmarks and facial movements and is sensitive to paralysis. Given its efficiency, it serves as a useful tool in the clinical setting for zonal facial movement analysis in comprehensive facial nerve rehabilitation programs.

  7. Management-by-Results and Performance Measurement in Universities--Implications for Work Motivation

    Science.gov (United States)

    Kallio, Kirsi-Mari; Kallio, Tomi J.

    2014-01-01

    The article focuses on the effects of management-by-results from the perspective of the work motivation of university employees. The study is based on extensive survey data among employees at Finnish universities. According to the results, performance measurement is based on quantitative rather than qualitative measures, and the current…

  8. (According to TAS 16, Measurement After Recognition on Property, Plant andEquipment and Accounting İmplementation)

    OpenAIRE

    Örten, Remzi; Bayırlı, Rıdvan

    2007-01-01

    The objective of TAS 16 is to prescribe the accounting treatment for property, plant and equipment so that users of the financial statements can determine information about an entity’s investment in its property, plant and equipment and the changes in such investment. Property, plant and equipment have major importance within the total assets of companies and thus they are very significant in the determination of financial analysis. According to this standard, there are two methods cencerning...

  9. Against Journal Articles for Measuring Value in University Output

    Science.gov (United States)

    Mbali, C.

    2010-01-01

    The following lines of arguments against the metrics of journal articles is developed: (1) Textual output should no longer be main valued output; (2) Digitalization enables other ways of advancing knowledge; (3) Measures by journal article favours the disciplines of Natural Science and Engineering (NSE) and moulds other disciplines of Social…

  10. Measurement and control techniques for electric equipment development; Tecnicas de medicion y control para el desarrollo de equipos electricos

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Neblina, Joaquin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    In broad outlines the measuring and control techniques that are used in the electric equipment development in the short circuit laboratories, are described. In this article the utilization criteria of the traditional and modern (analogical and digital) instruments are described as well as the tendency towards the system`s integration for the automation of the measurement and control processes. Also, mention is made of the systems currently being developed at the Instituto de Investigaciones Electricas (IIE) to be applied at the Short Circuit Laboratories of Comision Federal de Electricidad (CFE) and of the IIE. [Espanol] Se describen a grandes rasgos las tecnicas de medicion y control que se emplean para el desarrollo de equipos electricos en los laboratorios de corto circuito. En este articulo se describen los criterios de utilizacion de los instrumentos tradicionales y modernos (analogicos y digitales), asi como la tendencia hacia la integracion de sistemas para la automatizacion de los procesos de medicion y control. Tambien se mencionan los sistemas que actualmente se desarrollan en el Instituto de Investigaciones Electricas (IIE) para aplicarlos en los Laboratorios de Corto Circuito de la Comision Federal de Electricidad (CFE) y del Instituto.

  11. Measurement and control techniques for electric equipment development; Tecnicas de medicion y control para el desarrollo de equipos electricos

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Neblina, Joaquin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    In broad outlines the measuring and control techniques that are used in the electric equipment development in the short circuit laboratories, are described. In this article the utilization criteria of the traditional and modern (analogical and digital) instruments are described as well as the tendency towards the system`s integration for the automation of the measurement and control processes. Also, mention is made of the systems currently being developed at the Instituto de Investigaciones Electricas (IIE) to be applied at the Short Circuit Laboratories of Comision Federal de Electricidad (CFE) and of the IIE. [Espanol] Se describen a grandes rasgos las tecnicas de medicion y control que se emplean para el desarrollo de equipos electricos en los laboratorios de corto circuito. En este articulo se describen los criterios de utilizacion de los instrumentos tradicionales y modernos (analogicos y digitales), asi como la tendencia hacia la integracion de sistemas para la automatizacion de los procesos de medicion y control. Tambien se mencionan los sistemas que actualmente se desarrollan en el Instituto de Investigaciones Electricas (IIE) para aplicarlos en los Laboratorios de Corto Circuito de la Comision Federal de Electricidad (CFE) y del Instituto.

  12. Development of sample assay system equipped with 3He Alternative Neutron Detectors (ASAS). (2) Results of ASAS measurement test

    International Nuclear Information System (INIS)

    Tanigawa, Masafumi; Mukai, Yasunobu; Kurita, Tsutomu; Makino, Risa; Nakamura, Hironobu; Tobita, Hiroshi; Ohzu, Akira; Kureta, Masatoshi; Seya, Michio

    2015-01-01

    Against the background of the serious shortage of 3 He gas, design and development of a new detector equipped ZnS/ 10 B 2 O 3 ceramic scintillation neutron detectors in JAEA, with the support of the government (the Ministry of Education, Culture, Sports, Science and Technology). The design of the alternative 3 He detector is referred from INVS (INVentory Sample assay system (HLNCC (High Level Neutron Coincidence Counter) type)) which is being used for the verification of MOX powder etc. and is named it as ASAS (Alternative Sample Assay System). In order to prove the Pu quantitative performance as an alternative technology, several measurement tests and comparison test with INVS were conducted using ASAS. In these tests, evaluation of fundamental performance (counting efficiency and die-away time) and uncertainty evaluations were implemented. As a result, although fundamental performance of ASAS was not achieved to the one of INVS, we could confirm that ASAS has almost the same Pu quantitative performance including measurement uncertainty as that of INVS. (author)

  13. High-throughput measurement of rice tillers using a conveyor equipped with x-ray computed tomography

    Science.gov (United States)

    Yang, Wanneng; Xu, Xiaochun; Duan, Lingfeng; Luo, Qingming; Chen, Shangbin; Zeng, Shaoqun; Liu, Qian

    2011-02-01

    Tillering is one of the most important agronomic traits because the number of shoots per plant determines panicle number, a key component of grain yield. The conventional method of counting tillers is still manual. Under the condition of mass measurement, the accuracy and efficiency could be gradually degraded along with fatigue of experienced staff. Thus, manual measurement, including counting and recording, is not only time consuming but also lack objectivity. To automate this process, we developed a high-throughput facility, dubbed high-throughput system for measuring automatically rice tillers (H-SMART), for measuring rice tillers based on a conventional x-ray computed tomography (CT) system and industrial conveyor. Each pot-grown rice plant was delivered into the CT system for scanning via the conveyor equipment. A filtered back-projection algorithm was used to reconstruct the transverse section image of the rice culms. The number of tillers was then automatically extracted by image segmentation. To evaluate the accuracy of this system, three batches of rice at different growth stages (tillering, heading, or filling) were tested, yielding absolute mean absolute errors of 0.22, 0.36, and 0.36, respectively. Subsequently, the complete machine was used under industry conditions to estimate its efficiency, which was 4320 pots per continuous 24 h workday. Thus, the H-SMART could determine the number of tillers of pot-grown rice plants, providing three advantages over the manual tillering method: absence of human disturbance, automation, and high throughput. This facility expands the application of agricultural photonics in plant phenomics.

  14. Clinical Quality Performance Measurement: An Example of a University Hospital

    Directory of Open Access Journals (Sweden)

    Mehmet Nurullah Kurutkan

    2014-06-01

    CONCLUSiON: We determined that The Accountability Measures of the Joint Commission could be applied in the present conditions of Turkey. Only the Pneumonia package needs new requirements to be specified for Turkey. There is no need for a compatibility studies as for the others. Surgical care, heart attack, perinatal and venous thromboembolism packages are the ideal packages for Turkey. [TAF Prev Med Bull 2014; 13(3.000: 201-208

  15. Measurement of the irradiation of generating lamps of radiation ultraviolet type A used in tan equipment Sportarredo model Ringo 1200

    International Nuclear Information System (INIS)

    Gama T, G.

    2010-09-01

    In the last years has been developed in the cosmetology market the application of ultraviolet radiation (UV) in known equipment s as cameras or tan beds to obtain a change in the pigmentation of the skin. In Mexico, this fashion has entered without the appropriate recommendations of prevention against the risks of the adverse effects from the disproportionate exhibition to such non ionizing energy form; which is electromagnetic radiation in the interval of 400 nm to 100 nm of wave longitude, classified in near UV-A of 400 nm to 315 nm, and distant: UV-B of 315 nm to 280 nm and UV-C of 280 nm to 100 nm. Therefore, they have not been included in the national normative the necessary regulations regarding the operation parameters of the tan cameras for the E irradiation levels. The level E is defined as the incident radiation power in a receiver surface to a specific localization and relative orientation to the radiant surface expressed in units of the International System, W/m 2 or MW/cm 2 . The objective of this work is to show the measurement results for the E of a camera that contains two emitters arrangements, a first to whole body that consist of 8 lamp pairs model B17L of 160 Watts, which will have a nominal E of 358 W/m 2 (35.8 MW/cm 2 ) for UV type A and 3.3 W/m 2 (0.33 MW/cm 2 ) for UV type B; one second to face of 8 lamps model KALFASUN 630, with an E of 568 W/m 2 (56.8 MW/cm 2 ) for UV type A and 2.97 W/m 2 (0.297 MW/cm 2 ) for UV type B. The E measurements are carried out for UV-A with the body and face lamp, respectively; with two instruments: photometer mark Sportarredo, model BF01, series E009, and radiometer mark Ets without specified model. Additional the treatment time is verified with the chronometer of the digital screen of the equipment comparing it with a digital meter with resolution of 0.001 s. Conclusion: the lamps do not fulfill the E nominal values reported by the manufacturer, being minors 3.2 to 1.75 times their nominal value for the body

  16. Las Matematicas: Lenguaje Universal. Nivel 3: La Medida (Mathematics: A Universal Language. Level 3: Measurement).

    Science.gov (United States)

    Dissemination and Assessment Center for Bilingual Education, Austin, TX.

    This is one of a series of student booklets designed for use in a bilingual mathematics program in grades 6-8. The general format is to present each page in both Spanish and English. The mathematical topics in this booklet include liquid, dry, linear, weight, and time measures. (MK)

  17. Needle Stick Injuries and their Related Safety Measures among Nurses in a University Hospital, Shiraz, Iran

    Directory of Open Access Journals (Sweden)

    Mehdi Jahangiri

    2016-03-01

    Conclusion: The study showed a high prevalence of NSIs among nurses. Supportive measures such as improving injection practices, modification of working schedule, planning training programs targeted at using personal protective equipment, and providing an adequate number of safety facilities such as puncture resistant disposal containers and engineered safe devices are essential for the effective prevention of NSI incidents among the studied nurses.

  18. Chair in mechanical equipment in the mining industry and geotechnics at Clausthal Technological University; Professur fuer maschinelle Betriebsmittel in Bergbau und Geotechnik an der TU Clausthal

    Energy Technology Data Exchange (ETDEWEB)

    Langefeld, O.; Bergmann, O. [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). Inst. fuer Bergbau

    2002-10-10

    The aim of this chair at the Institute for Mining at Clausthal Technological University is to familiarise the future engineer with the state of the art in the field of mechanical equipment. The main emphasis of the teaching is in particular the description of coal-mining and roadheading machines as well as conveying and storage technology. In the field of research basic investigations are currently being conducted on flexible bulk material containers, on determination of heat characteristics of insulating and construction materials as well as development of direct methanol fuel cells. (orig.) [German] Den zukuenftigen Ingenieur mit dem Stand der Technik im Bereich der maschinellen Betriebsmittel vertraut zu machen, ist das Ziel dieser Professur des Instituts fuer Bergbau an der TU Clausthal. Schwerpunkte der Lehre sind insbesondere die Darstellung von Gewinnungs- und Vortriebsmaschinen sowie die Foerder- und Lagertechnik. Auf dem Gebiet der Forschung werden zur Zeit Grundlagenuntersuchungen an flexiblem Schuettgutbehaeltern, an der Ermittlung waermetechnischer Kennwerte von Isolier- und Baustoffen sowie die Entwicklung von Direkten Methanolbrennstoffzellen betrieben. (orig.)

  19. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  20. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures

    International Nuclear Information System (INIS)

    Bottaro, Marcio

    2012-01-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10 8 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  1. Universal resources for approximate and stochastic measurement-based quantum computation

    International Nuclear Information System (INIS)

    Mora, Caterina E.; Piani, Marco; Miyake, Akimasa; Van den Nest, Maarten; Duer, Wolfgang; Briegel, Hans J.

    2010-01-01

    We investigate which quantum states can serve as universal resources for approximate and stochastic measurement-based quantum computation in the sense that any quantum state can be generated from a given resource by means of single-qubit (local) operations assisted by classical communication. More precisely, we consider the approximate and stochastic generation of states, resulting, for example, from a restriction to finite measurement settings or from possible imperfections in the resources or local operations. We show that entanglement-based criteria for universality obtained in M. Van den Nest et al. [New J. Phys. 9, 204 (2007)] for the exact, deterministic case can be lifted to the much more general approximate, stochastic case. This allows us to move from the idealized situation (exact, deterministic universality) considered in previous works to the practically relevant context of nonperfect state preparation. We find that any entanglement measure fulfilling some basic requirements needs to reach its maximum value on some element of an approximate, stochastic universal family of resource states, as the resource size grows. This allows us to rule out various families of states as being approximate, stochastic universal. We prove that approximate, stochastic universality is in general a weaker requirement than deterministic, exact universality and provide resources that are efficient approximate universal, but not exact deterministic universal. We also study the robustness of universal resources for measurement-based quantum computation under realistic assumptions about the (imperfect) generation and manipulation of entangled states, giving an explicit expression for the impact that errors made in the preparation of the resource have on the possibility to use it for universal approximate and stochastic state preparation. Finally, we discuss the relation between our entanglement-based criteria and recent results regarding the uselessness of states with a high

  2. Resolution of Unresolved Safety Issue A-48, ''Hydrogen control measures and effects of hydrogen burns on safety equipment''

    International Nuclear Information System (INIS)

    Ferrell, C.M.; Soffer, L.

    1989-09-01

    Unresolved Safety Issue (USI) A-48 arose as a result of the large amount of hydrogen generated and burned within containment during the Three Mile Island accident. This issue covers hydrogen control measures for recoverable degraded-core accidents for all boiling-water reactors (BWRs) and those pressurized-water reactors (PWRs) with ice-condenser containments. The Commission and the nuclear industry have sponsored extensive research in this area, which has led to significant revision of the Commission's hydrogen control regulations, given in Title 10, Code of Federal Regulations, Part 50 (10 CFR 50), Section 50.44. BWRs having Mark I and II containments are presently required to operate with inerted containment atmospheres that effectively prevent hydrogen combustion. BWRs with Mark III containments and PWRs with ice-condenser containments are now required to be equipped with hydrogen control systems to protect containment integrity and safety systems inside containment. Industry has chosen to use hydrogen igniter systems to burn hydrogen produced in a controlled fashion to prevent damage. An independent review by a Committee of the National Research Council concluded that, for most accident scenarios, current regulatory requirements make it highly unlikely that hydrogen detonation would be the cause of containment failure. On the basis of the extensive research effort conducted and current regulatory requirements, including their implementation, the staff concludes that no new regulatory guidance on hydrogen control for recoverable degraded-core accidents for these types of plants is necessary and that USI A-48 is resolved

  3. Collaboration in Action: Measuring and Improving Contracting Performance in the University of California Contracting Network

    Science.gov (United States)

    Tran, Tam; Bowman-Carpio, LeeAnna; Buscher, Nate; Davidson, Pamela; Ford, Jennifer J.; Jenkins, Erick; Kalay, Hillary Noll; Nakazono, Terry; Orescan, Helene; Sak, Rachael; Shin, Irene

    2017-01-01

    In 2013, the University of California, Biomedical Research, Acceleration, Integration, and Development (UC BRAID) convened a regional network of contracting directors from the five University of California (UC) health campuses to: (i) increase collaboration, (ii) operationalize and measure common metrics as a basis for performance improvement…

  4. Development an Instrument to Measure University Students' Attitude towards E-Learning

    Science.gov (United States)

    Mehra, Vandana; Omidian, Faranak

    2012-01-01

    The study of student's attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students' attitude towards e-learning. The scale was administered to 200 University students from two countries (India…

  5. Evaluation of fire safety measures at local universities in Kenya with ...

    African Journals Online (AJOL)

    This study establishes fire safety measures in place in local universities in Kenya, and ... fire suppression systems, fire detection and alarm systems and fire Hydrants. ... response backed by university management endorsement and support. The Directorate of occupational safety and health services should also make the ...

  6. Multipurpose radiometric equipment provided with a microcontroller for use in industrial applications (e.g., measurements of level, density, thickness, etc.)

    International Nuclear Information System (INIS)

    Kluger, A.; Popescu, C.; Patrascu, S.

    1998-01-01

    The goal of this research was to modernize the radiometric equipment used for the control and automation of technological processes. A microcontroller-equipped electronic block was designed and realized, capable of performing all the tasks of a radiometric system, regardless of the application range (i.e. measurement of density, thickness, level, composition, etc.) or the detector type employed. In this work, the experimental model for the multipurpose radiometric equipment was devised. The electronic unit was designed using a high performance controller 80C552 and was provided with low-power transceivers for RS-232 and RS-485 communication with a PC. The results of the measured parameters are displayed using a graphic liquid crystal display, LCD G 242 C, that allows both graphics and character display. (authors)

  7. Measuring effectiveness of a university by a parallel network DEA model

    Science.gov (United States)

    Kashim, Rosmaini; Kasim, Maznah Mat; Rahman, Rosshairy Abd

    2017-11-01

    Universities contribute significantly to the development of human capital and socio-economic improvement of a country. Due to that, Malaysian universities carried out various initiatives to improve their performance. Most studies have used the Data Envelopment Analysis (DEA) model to measure efficiency rather than effectiveness, even though, the measurement of effectiveness is important to realize how effective a university in achieving its ultimate goals. A university system has two major functions, namely teaching and research and every function has different resources based on its emphasis. Therefore, a university is actually structured as a parallel production system with its overall effectiveness is the aggregated effectiveness of teaching and research. Hence, this paper is proposing a parallel network DEA model to measure the effectiveness of a university. This model includes internal operations of both teaching and research functions into account in computing the effectiveness of a university system. In literature, the graduate and the number of program offered are defined as the outputs, then, the employed graduates and the numbers of programs accredited from professional bodies are considered as the outcomes for measuring the teaching effectiveness. Amount of grants is regarded as the output of research, while the different quality of publications considered as the outcomes of research. A system is considered effective if only all functions are effective. This model has been tested using a hypothetical set of data consisting of 14 faculties at a public university in Malaysia. The results show that none of the faculties is relatively effective for the overall performance. Three faculties are effective in teaching and two faculties are effective in research. The potential applications of the parallel network DEA model allow the top management of a university to identify weaknesses in any functions in their universities and take rational steps for improvement.

  8. A framework for performance measurement in university using extended network data envelopment analysis (DEA) structures

    Science.gov (United States)

    Kashim, Rosmaini; Kasim, Maznah Mat; Rahman, Rosshairy Abd

    2015-12-01

    Measuring university performance is essential for efficient allocation and utilization of educational resources. In most of the previous studies, performance measurement in universities emphasized the operational efficiency and resource utilization without investigating the university's ability to fulfill the needs of its stakeholders and society. Therefore, assessment of the performance of university should be separated into two stages namely efficiency and effectiveness. In conventional DEA analysis, a decision making unit (DMU) or in this context, a university is generally treated as a black-box which ignores the operation and interdependence of the internal processes. When this happens, the results obtained would be misleading. Thus, this paper suggest an alternative framework for measuring the overall performance of a university by incorporating both efficiency and effectiveness and applies network DEA model. The network DEA models are recommended because this approach takes into account the interrelationship between the processes of efficiency and effectiveness in the system. This framework also focuses on the university structure which is expanded from the hierarchical to form a series of horizontal relationship between subordinate units by assuming both intermediate unit and its subordinate units can generate output(s). Three conceptual models are proposed to evaluate the performance of a university. An efficiency model is developed at the first stage by using hierarchical network model. It is followed by an effectiveness model which take output(s) from the hierarchical structure at the first stage as a input(s) at the second stage. As a result, a new overall performance model is proposed by combining both efficiency and effectiveness models. Thus, once this overall model is realized and utilized, the university's top management can determine the overall performance of each unit more accurately and systematically. Besides that, the result from the network

  9. Universe

    CERN Document Server

    2009-01-01

    The Universe, is one book in the Britannica Illustrated Science Library Series that is correlated to the science curriculum in grades 5-8. The Britannica Illustrated Science Library is a visually compelling set that covers earth science, life science, and physical science in 16 volumes.  Created for ages 10 and up, each volume provides an overview on a subject and thoroughly explains it through detailed and powerful graphics-more than 1,000 per volume-that turn complex subjects into information that students can grasp.  Each volume contains a glossary with full definitions for vocabulary help and an index.

  10. Experimental equipment, ch. 6

    International Nuclear Information System (INIS)

    Boomstra, F.; Hoogenboom, A.M.; Prins, C.M.; Strasters, B.A.; Vermeer, A.; Wit, P. de; Zwol, N.A. van.

    1977-01-01

    The experimental equipment in use at Utrecht university is discussed. Attention is paid to the tandem Van de Graaff accelerator and the 4MV and 1MV accelerators. The detection systems for gamma-ray spectroscopy are reviewed with emphasis on the compton-suppression spectrometer. The data-handling system used for experiments with the tandem is also briefly discussed

  11. Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia

    Science.gov (United States)

    Bortolussi, S.; Protti, N.; Ferrari, M.; Postuma, I.; Fatemi, S.; Prata, M.; Ballarini, F.; Carante, M. P.; Farias, R.; González, S. J.; Marrale, M.; Gallo, S.; Bartolotta, A.; Iacoviello, G.; Nigg, D.; Altieri, S.

    2018-01-01

    University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been carried out, aimed at characterizing the neutron spectrum and the gamma dose component. The neutron spectrum has been measured by means of multifoil neutron activation spectrometry and a least squares unfolding algorithm; gamma dose was measured using alanine dosimeters. Results show that in a reference position the thermal neutron flux is (1.20 ± 0.03) ×1010 cm-2 s-1 when the reactor is working at the maximum power of 250 kW, with the epithermal and fast components, respectively, 2 and 3 orders of magnitude lower than the thermal component. The ratio of the gamma dose with respect to the thermal neutron fluence is 1.2 ×10-13 Gy/(n/cm2).

  12. A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

    Directory of Open Access Journals (Sweden)

    Brian C W Kot

    Full Text Available Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859-0.976. A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854-0.984, FCUS: ICC = 0.709-0.954. As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings.

  13. Evaluating performance characteristics of x-ray equipment and film systems without the use of electronic measurement and/or special instruments

    International Nuclear Information System (INIS)

    Bianchi, M.F.; DeNitto, C.; Liscio, A.; Scala, N.

    2004-01-01

    Measurement and control of characteristics of NDT equipment and system that produce output to be interpreted by inspector is one of the most important tools for NDT reliability. Control activity should be based on: initial accurate measurement and calibration; periodical check to assure maintenance of calibration status; and, immediate verification and corrective action when any malfunctioning is suspected. 'Self-calibration' intended as capability of NDT facility to calibrate and control its own equipment and systems is very important for continuous and reliable activity. Typical approach based on this philosophy is ASTM E317 'Standard Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-Echo Examination Instruments and Systems Without the Use of Electronic Measurement Instruments' that is applicable to shop or field conditions. Is 'Self-calibration' applicable to radiographic system too? Many characteristics can be self-determined according to existing practices and methods, but other ones require assistance and cooperation of supplier both for film system and x-ray equipment. A certified film system being controlled by pre-exposed filmstrips can be adopted as 'measurement device' for X-ray output concerning both intensity and contrast. Basically x-ray equipment manufacturer performs initial accurate measurement and calibration using electronic measurement and/or special instrumentation as necessary. Then specific film set on 'low-price' blocks and specimens is produced according to standard practice whose guidelines are supplied by this paper. Film set, blocks, specimens and results referred to specific film system will be the reference kit for periodical check in NDT facility. This paper supplies some guidelines for standard practice based on testing using mainly GE Inspection Technologies radiographic system being available in Avio facilities. (author)

  14. UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; William H. Morrison

    2014-03-01

    Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of

  15. THE PERFORMANCE OF SERVQUAL TO MEASURE SERVICE QUALITY IN PRIVATE UNIVERSITY

    Directory of Open Access Journals (Sweden)

    Leonnard

    2018-03-01

    Full Text Available The increasing number of educational services has caused a high competition in this industry. In Indonesia, the number of private universities is the highest compared to state universities and other forms of higher education institutions. Ability to predict factors that are important in providing educational services to achieve student satisfaction and make them loyal to the university is highly necessary. In this study, we investigated the main factors of service quality that affect student satisfaction and loyalty by collecting data from 319 students from London School of Public Relation in Jakarta. Structural equation modeling (SEM was employed to analyze the data through AMOS 24 statistical package. The findings indicated that the main factors influencing student satisfaction in private university are tangible and reliability consisting of: 1 comfortable lecture rooms, 2 adequate library facilities, 3 neat staff appearance, 4 non-discriminatory treatments provided by staff and lecturers, 5 high ability and knowledge provided by staffs and lecturers, and 6 appropriate academic services provided by the university. Student satisfaction with these factors would indirectly lead to loyalty to the university. Finally, service quality measurement through SERVQUAL was redundant as a model to measure the effect of service quality in educational service.

  16. The Cost of Maintaining Educational Communications Equipment.

    Science.gov (United States)

    Humphrey, David A.

    Tentative formulas for calculating the cost of maintaining educational communications equipment are proposed. The formulas are based on a survey of campuses of the State University of New York. The survey analyzed the types of equipment to be maintained, types of maintenance, who uses the equipment, who services the equipment, and the cost…

  17. Hypertension and anthropometry measurement on academic staff at public universities in Malaysia

    Science.gov (United States)

    Zulkifli, Ilya Zulaikha; Abdullah, Mohammad Nasir; Baharuddin, Mohd Sapuan; Arul, Elizabeth

    2015-12-01

    Hypertension or most commonly known as high blood pressure is a non-communicable disease affecting to health of people with non-detectible cause (primary) and some with determined causes (secondary). The prevalence of hypertension morbidity was very high globally, the consequences of the disease if not been treated is death. The purpose of this study was to determine the relationship between hypertension and anthropometry measurements such as weight, height and body mass index among academic staff in public universities in Malaysia. The design for this study was cross-sectional and the method for data collection was mailed questionnaire. The initial sample size for this study was 189, therefore, 500 questionnaires were distributed to randomly selected academicians in public universities, colleges and polytechnics in Malaysia. However, only 101 questionnaires were returned and were analysed in this study. The target population were academicians which includes lecturers and senior lecturers in public universities in Malaysia. The methods of analysis employed was logistic regression and frequency analysis. It was found that weight, height and body mass index (BMI) have no significant relationship with hypertension but based on the Crude Odd Ratio, all these three anthropometry measures showed that there were protective risk of hypertension among lecturers and senior lecturers in public university, Malaysia. In a nutshell, there were no evidence to conclude that anthropometry measurements can affect hypertension status among academic staff at public university.

  18. Observation of structural universality in disordered systems using bulk diffusion measurement

    Science.gov (United States)

    Papaioannou, Antonios; Novikov, Dmitry S.; Fieremans, Els; Boutis, Gregory S.

    2017-12-01

    We report on an experimental observation of classical diffusion distinguishing between structural universality classes of disordered systems in one dimension. Samples of hyperuniform and short-range disorder were designed, characterized by the statistics of the placement of micrometer-thin parallel permeable barriers, and the time-dependent diffusion coefficient was measured by NMR methods over three orders of magnitude in time. The relation between the structural exponent, characterizing disorder universality class, and the dynamical exponent of the diffusion coefficient is experimentally verified. The experimentally established relation between structure and transport exemplifies the hierarchical nature of structural complexity—dynamics are mainly determined by the universality class, whereas microscopic parameters affect the nonuniversal coefficients. These results open the way for noninvasive characterization of structural correlations in porous media, complex materials, and biological tissues via a bulk diffusion measurement.

  19. Multibloc system electronic equipment: D.C. linear - logarithmic amplifier and periodmeter and wide range (pulses, fluctuations and direct current) measuring set

    International Nuclear Information System (INIS)

    Guerre, J.; Plaige, Y.; Vaux, C.

    1974-01-01

    The requirements which have led to the design of a specific equipment for reactor neutron control (Multibloc system) are briefly recalled. It is shown how, for reasons of saving the cost of installation, the development tended towards a multifunction performance from signals delivered by one detector. Two major achievments in accordance with the above trend are described: the D.C. linear - logarithmic amplifier and periodmeter, and the wide dynamics range measuring set [fr

  20. Total body composition measurements using in vivo neutron activation at the University of Washington

    International Nuclear Information System (INIS)

    Lewellen, T.L.

    1986-01-01

    The University of Washington Division of Nuclear Medicine has been using in vivo irradiation to study whole body calcium since 1969. Over 350 patients have been studied and currently five patients per week are being measured in support of research programs on bone wasting disease. (author)

  1. Measuring the Quality of Life of University Students. Research Monograph Series. Volume 1.

    Science.gov (United States)

    Roberts, Lance W.; Clifton, Rodney A.

    This study sought to develop a valid set of scales in the cognitive and affective domains for measuring the quality of life of university students. In addition the study attempted to illustrate the usefulness of Thomas Piazza's procedures for constructing valid scales in educational research. Piazza's method involves a multi-step construction of…

  2. Performance management in universities : Effects of the transition to more quantitative measurement systems

    NARCIS (Netherlands)

    ter Bogt, H.J.; Scapens, R.W.

    2012-01-01

    The measurement of research and teaching performance is increasingly common within universities, driven probably by the rise of New Public Management (NPM). Although changing over time and varying from country to country, NPM involves the use of private sector methods in the public sector.

  3. Validation of measures for assessing management and evaluation skills in university professors

    OpenAIRE

    Domínguez Guedea, Miriam; Laros, Jacobo; Domínguez Guedea, Rosario–Leticia

    2010-01-01

    We present the results of a validation process two scales to measure skills of teachers teaching in a public university in Mexico. The elements to consider in this project were checking to test the construct validity and reliability of the method of collection, as well as contributing to the technical dimension of the evaluation of teachers.

  4. Analysis of Detailed Energy Audits and Energy Use Measures of University Buildings

    Directory of Open Access Journals (Sweden)

    Kęstutis Valančius

    2011-12-01

    Full Text Available The paper explains the results of a detailed energy audit of the buildings of Vilnius Gediminas Technical University. Energy audits were performed with reference to the international scientific project. The article presents the methodology and results of detailed measurements of energy balance characteristics.Article in Lithuanian

  5. Generalizability Theory Reliability of Written Expression Curriculum-Based Measurement in Universal Screening

    Science.gov (United States)

    Keller-Margulis, Milena A.; Mercer, Sterett H.; Thomas, Erin L.

    2016-01-01

    The purpose of this study was to examine the reliability of written expression curriculum-based measurement (WE-CBM) in the context of universal screening from a generalizability theory framework. Students in second through fifth grade (n = 145) participated in the study. The sample included 54% female students, 49% White students, 23% African…

  6. Research and Teaching: A New Tool for Measuring Student Behavioral Engagement in Large University Classes

    Science.gov (United States)

    Lane, Erin S.; Harris, Sara E.

    2015-01-01

    The authors developed a classroom observation protocol for quantitatively measuring student engagement in large university classes. The Behavioral Engagement Related to instruction (BERI) protocol can be used to provide timely feedback to instructors as to how they can improve student engagement in their classrooms.

  7. A Proposed Model for Measuring Performance of the University-Industry Collaboration in Open Innovation

    Directory of Open Access Journals (Sweden)

    Anca Draghici

    2017-06-01

    Full Text Available The paper aims to present a scientific approach to the creation, testing and validation of a model for performance measurement for university-industry collaboration (UIC. The main idea of the design process is to capitalize on existing success factors, facilitators and opportunities (motivation factors, knowledge transfer channels and identified benefits and to diminish or avoid potential threats and barriers that might interfere with such collaborations. The main purpose of the applied methodology is to identify solutions and measures to overcome the disadvantages, conflicts or risk issues and to facilitate the open innovation of industrial companies and universities. The methodology adopted was differentiated by two perspectives: (1 a business model reflecting the university perspective along with an inventory of key performance indicators (KPIs; (2 a performance measurement model (including performance criteria and indicators and an associated methodology (assimilated to an audit that could help companies increase collaboration with universities in the context of open innovation. In addition, in order to operationalize the proposed model (facilitating practical implementation, an Excel tool has been created to help identifying potential sources of innovation. The main contributions of the research concern the expansion of UICs knowledge to enhance open innovation and to define an effective performance measurement model and instrument (tested and validated by a case study for companies.

  8. Measurement value analysis overall equipment effectiveness (OEE) packaging process in line 2 (Case Study of PT. MBI Tbk)

    Science.gov (United States)

    Rimawan, Erry; Kholil, Muhammad; Hendri

    2018-03-01

    PT. MBI Tbk is engaged in the manufacture of beverage industry, where the company’s production is based on the magnitude of customer demand that is marketing offices that had been scattered in various regions of Indonesia. In the packaging process steps in PT.MBI through the line 3 lines including racking, canning line, bottling line. In the canning process to existing packing on Line 2 (canning line), there are some machines that are used continuously, among other Depalletizer machine, filler machine, can seamer machine, pasteurizer machine, machine FLD, Wrap Around engine, engine Shrink Wrap. Due to the large demand from customers that is relentless, therefore the calculation of overall equipment effectiveness (OEE) as a whole on line 2 (canning line) is needed in order to make improvements continuously (Continuous Improvement) at line 2 (canning line). This study aims to determine the value of overall equipment effectiveness (OEE) and Losses of the most influential of the big six OEE Losses focused on equipment or machinery as a whole into a single unit that is on the line 2, which will then be known root cause of the losses that occur from the research over the field. From the calculation of overall equipment effectiveness (OEE), there are two ratios are still poor and under world-class standards, while the ratio of the availability of 88.85% of the world-class standards by 90% and the performance ratio of 78.51% of the standard world class by 95%, whereas for quality ratio has entered the world-class standard that is equal to 99.90%. Thus the value of OEE on Line 2 line is below world class standards. In this study there were only five losses, which can be identified, and while the losses were very influential, namely the Speed Reduced Losses, losses, these losses accounted for the largest percentage of the value of the rate of 19.12%, of the results of this study losses occurred due to poor surveillance systems (less good) that causes the employee or

  9. Radiation Measurement from Mobile Base Stations at a University Campus in Malaysia

    OpenAIRE

    Md. R. Islam; Othman O. Khalifa; Liakot Ali; Amir Azli; Mohd Zulkarnain

    2006-01-01

    The tremendous growth of telecommunication industry results the number of hand phone users increases everyday. In order to support the growing number of users, the mobile base stations can be seen in almost everywhere. This scenario has created uncomfortable feelings to the people that they may be affected by the radiations from antennas. A measurement was done at student hostels and office premises near to base stations in International Islamic University Malaysia, Gombak campus. Measured va...

  10. Safeguards techniques and equipment

    International Nuclear Information System (INIS)

    1997-01-01

    The current booklet is intended to give a full and balanced description of the techniques and equipment used for both nuclear material accountancy and containment and surveillance measures, and for the new safeguards measure of environmental sampling. As new verification measures continue to be developed, the material in the booklet will be periodically reviewed and updated versions issued. (author)

  11. Present status of TANDETRON accelerator age measurement facility in Nagoya University

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Toshio; Ikeda, Akiko; Ota, Tomoko; Okuno, Mitsuru; Oda, Hirotaka; Aoki, Hiroshi; Ito, Seisuke; Adachi, Mamoru [Nagoya Univ. (Japan)

    1996-12-01

    Already 14 years have elapsed since a TANDETRON accelerator mass analyzer was introduced in Nagoya University. During this period, the research on environmental C-14 concentration distribution and the C-14 age measurement of environmental samples have been carried out by using C-14 as the tracer. The number of measurement as of the end of 1995 exceeded 5800. The TANDETRON analyzer has been utilized for research and education as the joint utilization facility within the university. As to the performance of the TANDETRON analyzer, C-14 measurement is feasible with 0.2-1 mg of the CO{sub 2} for forming graphite. The measurable limit of old age is 40-50 thousand years age, and the error of measurement is {+-}0.8-{+-}1.0% for relatively young samples when graphite targets are used, which can be attained by the measurement of 2-3 hours. In the old samples exceeding 20,000 years ago, as the age value becomes larger, the error increases. The state of operation and utilization is reported. In Nagoya University, the carbon dating system of Model 4130 AMS made in Netherlands was introduced in fiscal year 1995. (K.I.)

  12. Testing by photometric measurement and camera study of theoretical prediction of microvolume universal sessile dropshape

    International Nuclear Information System (INIS)

    Smith, S R P; O'Neill, M; McMillan, N D; Arthure, K; Smith, S; Riedel, S

    2011-01-01

    The approach to the theory of sessile dropshapes held on a cylindrical drophead is discussed. It reveals an 'undifferentiable' universal micro-dropshape for volumes below 3μL. Camera studies demonstrate the veracity of this prediction exploited in the design of a new microvolume spectrometer. The mean pathlength of light injected through a microvolume sessile drop has been determined both from the model and from experiment. Drop volumes determine accurately the mean pathlength and with this Beer's law relationship is experimentally confirmed. The Transmitted Light Drop Analyser uses this universal 'natural cuvette' to deliver both high-performance UV spectra and absorbance measurements at discrete wavelengths.

  13. DEVELOPMENT AN INSTRUMENT TO MEASURE UNIVERSITY STUDENTS' ATTITUDE TOWARDS E-LEARNING

    Directory of Open Access Journals (Sweden)

    Vandana MEHRA

    2012-01-01

    Full Text Available The study of student’s attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students’ attitude towards e-learning. The scale was administered to 200 University students from two countries (India and Iran .The 83-item attitude towards e-learning scale was developed on six domains as Perceived usefulness ; Intention to adopt e-learning; Ease of e-learning use; Technical and pedagogical support; E-learning stressors ; Pressure to use e-learning.

  14. DEVELOPMENT AN INSTRUMENT TO MEASURE UNIVERSITY STUDENTS' ATTITUDE TOWARDS E-LEARNING

    OpenAIRE

    Vandana MEHRA; Faranak OMIDIAN

    2012-01-01

    The study of student’s attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students’ attitude towards e-learning. The scale was administered to 200 University students from two countries (India and Iran) .The 83-item attitude towards e-learning scale was developed on six domains as Perceived usefulness ; Intention to adopt e-learning; Ease o...

  15. Student Wellbeing at a University in Post-Apartheid South Africa: A Comparison with a British University Sample Using the GP-CORE Measure

    Science.gov (United States)

    Young, Charles; Campbell, Megan

    2014-01-01

    This article provides GP-CORE norms for a South African university sample, which are compared to published data obtained from a United Kingdom university sample. The measure appears to be both reliable and valid for this multilingual and multicultural South African sample. The profiles of the psychological distress reported by white South African…

  16. Multiple regression analysis of anthropometric measurements influencing the cephalic index of male Japanese university students.

    Science.gov (United States)

    Hossain, Md Golam; Saw, Aik; Alam, Rashidul; Ohtsuki, Fumio; Kamarul, Tunku

    2013-09-01

    Cephalic index (CI), the ratio of head breadth to head length, is widely used to categorise human populations. The aim of this study was to access the impact of anthropometric measurements on the CI of male Japanese university students. This study included 1,215 male university students from Tokyo and Kyoto, selected using convenient sampling. Multiple regression analysis was used to determine the effect of anthropometric measurements on CI. The variance inflation factor (VIF) showed no evidence of a multicollinearity problem among independent variables. The coefficients of the regression line demonstrated a significant positive relationship between CI and minimum frontal breadth (p regression analysis showed a greater likelihood for minimum frontal breadth (p regression analysis revealed bizygomatic breadth, head circumference, minimum frontal breadth, head height and morphological facial height to be the best predictor craniofacial measurements with respect to CI. The results suggest that most of the variables considered in this study appear to influence the CI of adult male Japanese students.

  17. The measurement invariance of job diagnostic survey (JDS) across three university student groups

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Gomez, M.; Marin-Garcia, J.A.; Girado Omeara, M.

    2016-07-01

    The main purpose of this study is to apply a multigroup confirmatory analysis to examine the measurement invariance (MI) of the adapted version of the Job Diagnosis Survey (JDS) as a measurement tool that analyses the relationship between the features of teaching methodologies with university students’ motivation and satisfaction across data collected on different degrees and academic years. Design/methodology/approach: Confirmatory factor analysis was carried out using a multigroup structural equation model, using the program EQS 6.1 to test the invariance of the adapted version of JDS in a sample constituted by 535 student of a Spanish public university. The assessment of invariance included the levels of configural, metric, scalar, covariance and latent variables invariance. Several goodness-of-fit measures were assessed... (Author)

  18. A Balanced Scorecard for Open Innovation: Measuring the Impact of Industry-University Collaboration

    Science.gov (United States)

    Flores, Myrna; Al-Ashaab, Ahmed; Magyar, Andrea

    The Balanced Scorecard (BSC) can be considered as a strategic measurement tool. Since its first publication by Norton and Kaplan in the early 1990’s, many companies have applied it to measure four key aspects of their organisations’ performance: Financial, Customer, Internal Business Process, Learning and Growth. Although it is widely used in the business arena, this original BSC was not developed to assess the impact of collaborative research projects under an open innovation strategy, where the outputs of research and development (R&D) developed by collaborative projects undertaken by industry and universities should be measured in a different way. In fact, many companies are losing important opportunities to spur their R&D results by not being able to quantify the results of such collaborations. Therefore, this paper will propose a Scorecard to measure the outcomes of collaborative research. It is important to recall that this scorecard has been developed during a collaborative research project by CEMEX Research Group AG (Switzerland) and Cranfield University (UK). During such project, a survey was developed to carry out eleven face-to-face interviews in a sample of ten companies in UK, which provided important inputs to design such strategic scorecard. It was confirmed that a collaborative balanced scorecard is a very useful tool to measure, track and improve the impact of conducting collaborative projects with universities.

  19. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  20. Detection and measurement equipment of gases, its calibration and certification; Aparatos de deteccion y medida de gases, su calibracion y certificacion

    Energy Technology Data Exchange (ETDEWEB)

    Navarro Izquierdo, A.; Prado Herrero, M. D.; Lorenzo Bayona, L.

    2003-07-01

    The equipment for detection and measurement of gases must be certified by a laboratory recognized by the competent Administration. For it is needed to dispose of patters, instrumentation and procedures in order to get adequate calibration. Inside of the Madariaga Official Laboratory (LOM) it has been developed a laboratory for calibration of apparatus for detection and measurement of gasses. The procurement of mix of gasses pattern was realized by means of the volumetric dynamic method, and it is the first laboratory in Spain that uses this technique, that has been credited by ENAC. (Author)

  1. The measurement invariance of job diagnostic survey (JDS across three university student groups

    Directory of Open Access Journals (Sweden)

    Monica Martinez-Gomez

    2016-02-01

    Full Text Available Purpose: The main purpose of this study is to apply a multigroup confirmatory analysis to examine the measurement invariance (MI of the adapted version of the Job Diagnosis Survey (JDS as a measurement tool that analyses the relationship between the features of teaching methodologies with university students’ motivation and satisfaction across data collected on different degrees and academic years. Design/methodology/approach: Confirmatory factor analysis was carried out using a multigroup structural equation model, using the program EQS 6.1 to test the invariance of the adapted version of JDS in a sample constituted by 535 student of a Spanish public university. The assessment of invariance included the levels of configural, metric, scalar, covariance and latent variables invariance. Several goodness-of-fit measures were assessed. Findings: The results show that measurements are equivalent at the configural, metric, covariance and latent factors invariance. Although the hypotheses of scalar invariance is rejected, results suggest that JDS is partial strict invariant and has satisfactory psychometric properties on all samples. Research limitations/implications: The sample is framed in university students aged between 18 and 30 and for a questionnaire on teaching methodology and students' satisfaction in the context of a Spanish university and the generalization to other questionnaire, or population, should be proved with specific data. Furthermore, the sample size is rather small. Originality/value: In the current process of change that is taking place in universities according to the plan developed by the European Space of Higher Education, focused on increasing the student skills, validate instruments as the satisfaction scale of JDS, are necessary to evaluate students’ satisfaction with new active methodologies. These findings are useful for researchers since they add the first sample in which the MI of a student’s satisfaction survey

  2. Measurements of Radon Concentration in Several Wards of the University Clinical Center of Kosovo...

    OpenAIRE

    , Y. Halimi; , S. Kadiri; , G. Hodolli; , B. Xhafa; , A. Jonuzaj

    2016-01-01

    Understanding that what’s the level of environment pollution from radioactive pollutant in some wards of UCCK (University Clinical Center of Kosovo) in Prishtina are made measurements of α radiation which is the product of 222Rn and have been read doses of TLD to some staff workers in three wards of UCCK. All this is done to see the risk level of possible pollution. Concentration of radon 222Rn is measured with device CRM-510 portable instruments. During the measurements the apparatus has rec...

  3. Neutrons field in the neutronic measurements room of the Polytechnic University of Madrid

    International Nuclear Information System (INIS)

    Vega C, H. R.; Gallego, E.; Lorente, A.; Rubio O, I. P.

    2010-09-01

    Through of measurements and calculations of a Monte Carlo series has been characterized the neutronic field of the neutronic measurements room of Nuclear Engineering Department of the Polytechnic University of Madrid. The measurements were realized with the Bonner Spheres Spectrometer that allowed establish the spectra on the new stainless steel panel and at different distances measured regarding the source. The values of the speed of environmental equivalent dose were measured with an area monitor Bert hold Lb 6411. Through of Monte Carlo methods was built a detailed model of the room with the panel and the spectra were calculated and, with these the values of the environmental equivalent dose were obtained using the conversion coefficients of the ICRP 74 and the Bert hold Lb 6411 response. The calculated values were compared with those measured and was consistency among the results. (Author)

  4. CERN News: Selection of the type of superconducting coil for the Omega project; New intensity records at the proton synchrotron; Progress with the Spiral Reader film measuring equipment; New technique at transition energy on the proton synchrotron; CERN Courier 10th anniversary; Equipment travelling from and to Serpukhov

    CERN Multimedia

    1969-01-01

    CERN News: Selection of the type of superconducting coil for the Omega project; New intensity records at the proton synchrotron; Progress with the Spiral Reader film measuring equipment; New technique at transition energy on the proton synchrotron; CERN Courier 10th anniversary; Equipment travelling from and to Serpukhov

  5. Volume weighting the measure of the universe from classical slow-roll expansion

    Science.gov (United States)

    Sloan, David; Silk, Joseph

    2016-05-01

    One of the most frustrating issues in early universe cosmology centers on how to reconcile the vast choice of universes in string theory and in its most plausible high energy sibling, eternal inflation, which jointly generate the string landscape with the fine-tuned and hence relatively small number of universes that have undergone a large expansion and can accommodate observers and, in particular, galaxies. We show that such observations are highly favored for any system whereby physical parameters are distributed at a high energy scale, due to the conservation of the Liouville measure and the gauge nature of volume, asymptotically approaching a period of large isotropic expansion characterized by w =-1 . Our interpretation predicts that all observational probes for deviations from w =-1 in the foreseeable future are doomed to failure. The purpose of this paper is not to introduce a new measure for the multiverse, but rather to show how what is perhaps the most natural and well-known measure, volume weighting, arises as a consequence of the conservation of the Liouville measure on phase space during the classical slow-roll expansion.

  6. Measuring treatment costs of typical waste electrical and electronic equipment: A pre-research for Chinese policy making.

    Science.gov (United States)

    Li, Jinhui; Dong, Qingyin; Liu, Lili; Song, Qingbin

    2016-11-01

    Waste Electrical and Electronic Equipment (WEEE) volume is increasing, worldwide. In 2011, the Chinese government issued new regulations on WEEE recycling and disposal, establishing a WEEE treatment subsidy funded by a levy on producers of electrical and electronic equipment. In order to evaluate WEEE recycling treatment costs and revenue possibilities under the new regulations, and to propose suggestions for cost-effective WEEE management, a comprehensive revenue-expenditure model (REM), were established for this study, including 7 types of costs, 4 types of fees, and one type of revenue. Since TV sets dominated the volume of WEEE treated from 2013 to 2014, with a contribution rate of 87.3%, TV sets were taken as a representative case. Results showed that the treatment cost varied from 46.4RMB/unit to 82.5RMB/unit, with a treatment quantity of 130,000 units to 1,200,000 units per year in China. Collection cost accounted for the largest portion (about 70.0%), while taxes and fees (about 11.0 %) and labor cost (about 7.0 %) contributed less. The average costs for disposal, sales, and taxes had no influence on treatment quantity (TQ). TQ might have an adverse effect on average labor and management costs; while average collection and purchase fees, and financing costs, would vary with purchase price, and the average sales fees and taxes would vary with the sales of dismantled materials and other recycled products. Recycling enterprises could reduce their costs by setting up online and offline collection platforms, cooperating with individual collectors, creating door-to-door collection channels, improving production efficiency and reducing administrative expenditures. The government could provide economic incentives-such as subsidies, low-cost loans, tax cuts and credits-and could also raise public awareness of waste management and environmental protection, in order to capture some of the WEEE currently discarded into the general waste stream. Foreign companies with

  7. A study on strengthening measures of non-proliferation regime through the export control system of sensitive materials, equipment and technology related to nuclear activities

    International Nuclear Information System (INIS)

    Kikuchi, Masahiro; Kurosawa, Mitsuru; Komizo, Yasuyoshi

    2004-01-01

    The strengthened safeguards caused from safeguards experiences to Iraq and DPRK leads to the expansion of the IAEA's activities for verification of all nuclear activities as well as verification of nuclear material in the States. The purpose of the activities, of course, includes detection of undeclared exports and imports of specified equipment and non-nuclear material. The Additional Protocol to the agreements between States and the IAEA for the application of safeguards requires to the States to declare the exports and imports information regarding specified equipment and non-nuclear material corresponding to the export control list that is established by the nuclear suppliers group. The Additional Protocol also insists the IAEA's right to access to the location identified by the State to resolve a question related to the declarations. Recently, the IAEA detected the black market group of the sensitive materials, equipment and technologies relevant to the nuclear proliferation through the safeguards activities to Iran and Libya. International community stated deeply concerns to the indecent facts. This paper would discuss and propose the supplemental strengthening measures of non-proliferation regime by effective combination of the safeguards activities under additional protocol and the export control regime. (author)

  8. Differential cross-section measurements at the University of Kentucky - Adventures in analysis

    International Nuclear Information System (INIS)

    Vanhoy, J.R.; Garza, E.A.; Steves, J.L.; Hicks, S.F.; Henderson, S.L.; Sidwell, L.C.; Champine, B.R.; Crider, B.P.; Liu, S.H.; Peters, E.E.; Prados-Estevez, F.M.; McEllistrem, M.T.; Ross, T.J.; Yates, S.W.

    2014-01-01

    Elastic and inelastic neutron scattering cross-sections are determined at the University of Kentucky Accelerator Laboratory (UKAL) 1 using time-of-flight techniques at incident energies in the fast neutron region. Measurements have been completed for scattering from 23 Na and for the 23 Na(n,n'γ) reaction; similar measurements are in progress for 54 Fe. Commencing in the summer of 2014, measurements will address 56 Fe. An overview of the facilities and instrumentation at UKAL is given, and our measurement and analysis procedures are outlined. Of particular concern are portions of the analysis which limit the accuracy and precision of the measurements. We briefly examine detector efficiencies derived from the 3 H(p,n) cross-sections, attenuation and multiple scattering corrections, and neutron and γ-ray cross-sections standardizations. (authors)

  9. A Proposed Model for Measuring Performance of the University-Industry Collaboration in Open Innovation

    OpenAIRE

    Anca Draghici; Larisa Ivascu; Adrian Mateescu; George Draghici

    2017-01-01

    The paper aims to present a scientific approach to the creation, testing and validation of a model for performance measurement for university-industry collaboration (UIC). The main idea of the design process is to capitalize on existing success factors, facilitators and opportunities (motivation factors, knowledge transfer channels and identified benefits) and to diminish or avoid potential threats and barriers that might interfere with such collaborations. The main purpose ...

  10. Measurement and analysis of leakage neutron energy spectra around the Kinki University Reactor, UTR-KINKI

    CERN Document Server

    Ogawa, Y; Sagawa, H; Tsujimoto, T

    2002-01-01

    The highly sensitive cylindrical multi-moderator type neutron spectrometer was constructed for measurement of low level environmental neutrons. This neutron spectrometer was applied for the determination of leakage neutron energy spectra around the Kinki University Reactor. The analysis of the leakage neutron energy spectra was performed by MCNP Monte Carlo code. From the obtained results, the agreement between the MCNP predictions and the experimentally determined values is fairly good, which indicates the MCNP model is correctly simulating the UTR-KINKI.

  11. Measuring the universe our historic quest to chart the horizons of space and time

    CERN Document Server

    Ferguson, Kitty

    1999-01-01

    More than 2,000 years ago, Eratosthenes, in Alexandria, used a stick, a hole in the ground, sunllght at summer solstice, and elementary geometry to measure the circumference of the Earth with surprising accuracy, long before anyone was able to circumnavigate it. Today, scientists are attempting to measure the entire universe and to determine its origin. Although the methods have changed, the quest to chart the horizons of space and time continues to be one of the great adventures of science. Measuring the Universe is an eloquent chronicle of the men and women– from Aristarchus to Cassini, Sir Isaac Newton to Henrietta Leavitt and Stephen Hawking–who have gradually unlocked the mysteries of "how far" and in so doing have changed our ideas about the size and nature of the universe and our place in it. Kitty Ferguson reveals their methods to have been as inventive as their results were–and are–eye-opening. Advances such as Copernicus's revolutionary insights about the arrangement of the solar system, Wi...

  12. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  13. Implementation of New Reactivity Measurement System and New Reactor Noise Analysis Equipment in a VVER-440 Nuclear Power Plant

    Science.gov (United States)

    Vegh, János; Kiss, Sándor; Lipcsei, Sándor; Horvath, Csaba; Pos, István; Kiss, Gábor

    2010-10-01

    The paper deals with two recently developed, high-precision nuclear measurement systems installed at the VVER-440 units of the Hungarian Paks NPP. Both developments were motivated by the reactor power increase to 108%, and by the planned plant service time extension. The first part describes the RMR start-up reactivity measurement system with advanced services. High-precision picoampere meters were installed at each reactor unit and measured ionization chamber current signals are handled by a portable computer providing data acquisition and online reactivity calculation service. Detailed offline evaluation and analysis of reactor start-up measurements can be performed on the portable unit, too. The second part of the paper describes a new reactor noise diagnostics system using state-of-the-art data acquisition hardware and signal processing methods. Details of the new reactor noise measurement evaluation software are also outlined. Noise diagnostics at Paks NPP is a standard tool for core anomaly detection and for long-term noise trend monitoring. Regular application of these systems is illustrated by real plant data, e.g., results of standard reactivity measurements during a reactor startup session are given. Noise applications are also illustrated by real plant measurements; results of core anomaly detection are presented.

  14. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    Science.gov (United States)

    Rey, Charles A.

    1991-03-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  15. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    Science.gov (United States)

    Rey, Charles A.

    1991-01-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  16. Development of high time-resolution laser flash equipment for thermal diffusivity measurements using miniature-size specimens

    International Nuclear Information System (INIS)

    Shikama, Tatsuo; Namba, Chusei; Kosuda, Michinori; Maeda, Yukio.

    1994-01-01

    For measurements of thermal diffusivity of miniature-size specimens heavily irradiated by neutrons, a new Q-switched laser-flash instrument was developed. In the present instrument the time-resolution was improved to 0.1 ms by using a laser-pulse width of 25 ns. The realization of high time-resolution made it possible to measure the thermal diffusivity of thin specimens. It is expected that copper of 0.7 mm thick, and SUS 304 of 0.1 mm could be used for the measurements. In case of ATJ graphite, 0.5 mm thick specimen could be used for the reliable measurement in the temperature range of 300-1300 K. (author)

  17. Development of measuring system for automobile unit assembly equipment; Jidosha buhin seisan setsubi no keisoku system kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Miura, M; Uchishiba, I; Fukunishi, T; Umemura, H [Toyota Motor Corp., Tokyo (Japan)

    1997-10-01

    This measuring system has two characteristics. The first characteristic is to shorten lead time from system design to production. The second characteristic is to accomplish system construction simply without computer technical knowledge. This measuring system consists of hardware module which are standardized according to functions and software packages which are composed of various functions. This system is put together according to purpose. When it was introduced into production line, it could shorten lead time of 1/3. 10 figs., 1 tab.

  18. Reviews Book: Voyage to the Heart of the Matter: The ATLAS Experiment at CERN Equipment: SEP Spectroscope Books: Quantum Gods / The Universe Places to visit: The Royal Institution of Great Britain Book: What is this Thing Called Science? Book: Don't be Such a Scientist: Talking Substance in the Age of Style Equipment: La Crosse Anemometer Book: Wonder and Delight Web Watch

    Science.gov (United States)

    2010-05-01

    WE RECOMMEND SEP Spectroscope Flatpacked classroom equipment for pupils aged 10 and over Quantum Gods Book attacks spiritualism and religion with physics The Universe Study of whether physics alone can explain origin of universe La Crosse Anemometer Handheld monitor is packed with useful features Wonder and Delight Essays in science education in honour of Eric Rogers WORTH A LOOK Voyage to the Heart of the Matter: The ATLAS Experiment at CERN Pop-up book explains background to complex physics The Royal Institution of Great Britain RI museum proves interesting but not ideal for teaching What is this Thing Called Science? Theory and history of science in an opinionated study Don't be Such a Scientist: Talking Substance in the Age of Style Explanation of how science is best communicated to the public WEB WATCH Particle physics simulations vary in complexity, usefulness and how well they work

  19. Calibration voltage test of non invasive meter for radiodiagnostic on equipment of constant potential X-ray

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Pereira, Marco A.G.S.

    2009-01-01

    This work evaluates the utilization of the non invasive voltage meter PTW Diavolt Universal in industrial X ray equipment of constant potential. With the performed measurements, the conclusion is that conclusion is possible, once his use limits are identified

  20. Time Resolution Dependence of Information Measures for Spiking Neurons: Scaling and Universality

    Directory of Open Access Journals (Sweden)

    James P Crutchfield

    2015-08-01

    Full Text Available The mutual information between stimulus and spike-train response is commonly used to monitor neural coding efficiency, but neuronal computation broadly conceived requires more refined and targeted information measures of input-output joint processes. A first step towards that larger goal is todevelop information measures for individual output processes, including information generation (entropy rate, stored information (statisticalcomplexity, predictable information (excess entropy, and active information accumulation (bound information rate. We calculate these for spike trains generated by a variety of noise-driven integrate-and-fire neurons as a function of time resolution and for alternating renewal processes. We show that their time-resolution dependence reveals coarse-grained structural properties of interspike interval statistics; e.g., $tau$-entropy rates that diverge less quickly than the firing rate indicate interspike interval correlations. We also find evidence that the excess entropy and regularized statistical complexity of different types of integrate-and-fire neurons are universal in the continuous-time limit in the sense that they do not depend on mechanism details. This suggests a surprising simplicity in the spike trains generated by these model neurons. Interestingly, neurons with gamma-distributed ISIs and neurons whose spike trains are alternating renewal processes do not fall into the same universality class. These results lead to two conclusions. First, the dependence of information measures on time resolution reveals mechanistic details about spike train generation. Second, information measures can be used as model selection tools for analyzing spike train processes.

  1. Beam position and phase measurements of microampere beams at the Michigan State University REA3 facility

    CERN Document Server

    Crisp, J; Durickovic, B; Kiupel, G; Krause, S; Leitner, D; Nash, S; Rodriguez, J A; Russo, T; Webber, R; Wittmer, W; Eddy, N; Briegel, C; Fellenz, B; Slimmer, D; Wendt, M

    2013-01-01

    A high power CW, heavy ion linac will be the driver accelerator for the Facility for Rare Isotope Beams (FRIB) being designed at Michigan State University (MSU). The linac requires a Beam Position Monitoring (BPM) system with better than 100 micron resolution at 100 microamperes beam current. A low beam current test of the candidate technology, button pick-ups and direct digital down-conversion signal processing, was conducted in the ReA3 re-accelerated beam facility at Michigan State University. The test is described. Beam position and phase measurement results, demonstrating ~250 micron and ~1.5 degree resolution in a 45 kHz bandwidth for a 1.0 microampere beam current, are reported.

  2. α-spectrometric device equipped with semi-conductors for direct measurement of transuranium elements on large area filters

    International Nuclear Information System (INIS)

    Fessler, H.; Pawelzik, J.

    1984-10-01

    A device was developed with an array of 8 silicon surface barrier detectors inside a vacuum chamber containing a rotating sample holder for large areas (200 mm diameter) aerosol filters. It serves for quick identification of α-emitters on these aerosol filters, and allows to measure the α-particles with a relatively constant efficiency along a filter diameter. Thus, the radiochemical treatment of single filters can be avoided. Troubles appeared in the course of development of defective semiconductors and their temperature dependence. To suppress the influence of temperature a cooling device was built. During practical testing a cross-efficiency of 13.6% was measured. It is possible to identify α-emitting nuclides with an activity of 10 -1 Bq per sample during about 2 hours of measuring time. Appropriate methodes of calculation are indicated. The data output of the device is suited for transfer to a computer. (orig./HP) [de

  3. Sustainable Academia: Translating the Vision of a Full Sustainable University into a Measurable Reality

    Directory of Open Access Journals (Sweden)

    Antonios Maragakis

    2017-04-01

    Full Text Available There is a growing public expectation that universities should start focusing on delivering sustainability. The topic of sustainability in higher education has gathered a significant amount of interest from students, academics, governments and international organizations. With a plethora of declarations, initiatives, marketing and assessments, there is a need to assess what the stakeholders want in order to make decisions regarding an institutions sustainability. Ultimately, students are the ones using these sustainability marketing materials to assist in their decision at which institution they will pursue their studies. The sheer volume of interpretations of the word sustainability with regards to higher education institution leaves ample room for potentially misguided initiatives or marketing. A universal system for assessing a higher educational institution’s sustainability has not been translated into a measurable reality. It is proposed that a universal system would help create a common understanding of sustainability within higher education institutions and would help in stakeholder understanding, institutional accountability and impactful application of sustainable initiatives. This research looked to answer if a holistic framework could be created that would aid stakeholders in reviewing a university’s level of sustainability. And, if so, if this vision of a fully sustainable university could be translated into a measurable reality. The research was approached in a structured way. Each chapter represents a published and peer-reviewed step towards addressing if a holistic framework could be created that would aid students in reviewing sustainability tools, assessments and marketing. The qualitative and quantitative conclusions from each chapter influenced the subsequent chapters, eventually leading to the creation and testing of two digital tools. The interpretations of these published chapters are found in the conclusion of this

  4. Cryogenic equipment

    International Nuclear Information System (INIS)

    Leger, L.; Javellaud, J.; Caro, C.; Gilguy, R.; Testard, O.

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [fr

  5. Synthesis of Algorithm for Range Measurement Equipment to Track Maneuvering Aircraft Using Data on Its Dynamic and Kinematic Parameters

    Science.gov (United States)

    Pudovkin, A. P.; Panasyuk, Yu N.; Danilov, S. N.; Moskvitin, S. P.

    2018-05-01

    The problem of improving automated air traffic control systems is considered through the example of the operation algorithm synthesis for a range measurement channel to track the aircraft, using its kinematic and dynamic parameters. The choice of the state and observation models has been justified, the computer simulations have been performed and the results of the investigated algorithms have been obtained.

  6. Development of automatic nuclear plate analyzing system equipped with TV measuring unit and its application to analysis of elementary particle reaction, 1

    International Nuclear Information System (INIS)

    Ushida, Noriyuki

    1987-01-01

    Various improvements are made on an analysis system which was previously reported. Twenty five emulsion plates, each with a decreased size of 3 cm x 3 cm, are mounted on a single acrylic resin sheet to reduce the required measurement time. An interface called New DOMS (digitized on-line microscope) is designed to reduce the analysis time and to improve the reliability of the analysis. The newly developed analysis system consists of five blocks: a stage block (with measuring range of 170 mm along the x and y axes and 2 mm along the z axis and an accuracy of 1 μm for each axis), DG-M10 host computer (with external storages for 15M byte hard disk and 368k byte minifloppy disk), DOMS interface (for control of the stage, operation of the graphic image and control of the CCD TV measuring unit), CCD TV measuring unit (equipped with a CCD TV camera to display the observed emulsion on a TV monitor for measuring the grain position), and measurement terminal (consisting of a picture monitor, video terminal module and keyboards). This report also shows a DOMS system function block diagram (crate controller and I/O, phase converter, motor controller, sub CPU for dysplay, graphic memory, ROM writer, power supply), describes the CCD TV measuring unit hardware (CCD TV camera, sync. separator, window generator, darkest point detector, mixer, focus counter), and outlines the connections among the components. (Nogami, K.)

  7. Measuring and improving quality in university hospitals in Canada: The Collaborative for Excellence in Healthcare Quality.

    Science.gov (United States)

    Backman, Chantal; Vanderloo, Saskia; Forster, Alan John

    2016-09-01

    Measuring and monitoring overall health system performance is complex and challenging but is crucial to improving quality of care. Today's health care organizations are increasingly being held accountable to develop and implement actions aimed at improving the quality of care, reducing costs, and achieving better patient-centered care. This paper describes the development of the Collaborative for Excellence in Healthcare Quality (CEHQ), a 5-year initiative to achieve higher quality of patient care in university hospitals across Canada. This bottom-up initiative took place between 2010 and 2015, and was successful in engaging health care leaders in the development of a common framework and set of performance measures for reporting and benchmarking, as well as working on initiatives to improve performance. Despite its successes, future efforts are needed to provide clear national leadership on standards for measuring performance. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. Navigation Signal Disturbances by Multipath Propagation - Scaled Measurements with a Universal Channel Sounder Architecture

    Science.gov (United States)

    Geise, Robert; Neubauer, Bjoern; Zimmer, Georg

    2015-11-01

    The performance of navigation systems is always reduced by unwanted multipath propagation. This is especially of practical importance for airborne navigation systems like the instrument landing system (ILS) or the VHF omni directional radio range (VOR). Nevertheless, the quantitative analysis of corresponding, potentially harmful multipath propagation disturbances is very difficult due to the large parameter space. Experimentally difficulties arise due to very expensive, real scale measurement campaigns and numerical simulation techniques still have shortcomings which are briefly discussed. In this contribution a new universal approach is introduced on how to measure very flexibly multipath propagation effects for arbitrary navigation systems using a channel sounder architecture in a scaled measurement environment. Two relevant scenarios of multipath propagation and the impact on navigation signals are presented. The first describes disturbances of the ILS due to large taxiing aircraft. The other example shows the influence of rotating wind turbines on the VOR.

  9. Direct current linear measurement sub-assembly data and test methods. Nuclear electronic equipment for control and monitoring panel

    International Nuclear Information System (INIS)

    1977-12-01

    The M.C.H./M.E.N.T.3 document is concerned with sub-assemblies intended for measuring on a linear scale the neutron fluence rate or radiation dose rate when connected with nuclear detectors working in current. The symbols used are described. Some definitions and a bibliography are given. The main characteristics of direct current linear measurement sub-assemblies are then described together with corresponding test methods. This type of instrument indicates on a linear scale the level of a direct current applied to its input. The document reviews linear sub-assemblies for general purpose applications, difference amplifiers for monitoring, and averaging amplifiers. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials and plant operators [fr

  10. Design and fabrication of a dead weight equipment to perform creep measurements on highly irradiated beryllium specimens

    International Nuclear Information System (INIS)

    Scibetta, M.; Pellettieri, A.; Wouters, P.; Leenaerts, A.; Verpoucke, G.

    2005-01-01

    Beryllium is an important material to be used in the blanket of fusion reactors. It acts as a neutron multiplier that allows tritium production. In order to use this material effectively, some data on creep and swelling behaviour are needed. This paper describes preliminary microstructural investigations and the qualification of a creep set-up that will be used to measure creep of highly irradiated beryllium from the BR2 research reactor matrix. (Author)

  11. Electronic measurement equipment for determining the cloud cover of the sky. Elektronisches Messgeraet zur Bestimmung des Bedeckungsgrades des Himmels

    Energy Technology Data Exchange (ETDEWEB)

    Siebrasse, R

    1990-01-18

    The invention is used for the automatic determination of the degree of cloud cover of the sky. Compared to the state of the art, the invention has the advantage that it manages without mechanical controls, like those of 'sky scanners' for example, and that the measuring head has a very simple, cheap and robust construction. In order to do without any mechanics, a group of 24 photo-transistors of type BPX 43 was mounted on a hemispherical support, which screens the individual elements from one another, so that a certain section of the sky is allocated to each transistor. The optical axes of the individual axes are distributed completely evenly, so that there is an even and beam-shaped alignment to the sky above the measurement head. The individual measurements of the 24 transistors together give a certain optical impression, a 'picture' or a brightness distribution of the sky hemisphere, which can be read by a suitable program via a normal commercial adaptor into a personal computer, where this distribution is compared with given distributions which have degrees of cover of 0-8 or 0-10 as heading. The given 'picture' which comes closest to the current distribution is ejected as the result, and the heading of this picture gives the current degree of cloud cover.

  12. Modeling and in situ measurements of biometeorological conditions in microenvironments within the Athens University Campus, Greece

    Science.gov (United States)

    Nastos, Panagiotis T.; Polychroni, Iliana D.

    2016-10-01

    The objective of this research is to assess and analyze the biometeorological perception in complex microenvironments in the Athens University Campus (AUC) using urban micromodels, such as RayMan. The human thermal sensation in such a place was considered of great significance due to the great gathering of student body and staff of the University. The quantification of the biometeorological conditions was succeeded by the estimation of the physiologically equivalent temperature (PET), which is a biometeorological index based on the human energy balance. We carried out, on one hand, field measurements of air temperature, relative humidity, wind speed, and global solar irradiance for different sites (building atrium, open area, and green atrium) of the examined microurban environment in order to calculate PET during January-July 2013. Additionally, on the other hand, PET modeling was performed using different sky-view factors and was compared to a reference site (meteorological station of Laboratory of Climatology and Atmospheric Environment, University of Athens). The global radiation was transferred to the examined sites with the RayMan model, which considers the sky-view factors for the adaptation of the radiation fluxes to simple and complex environments. The results of this study reveal the crucial importance of the existence of trees and green cover in a complex environment, as a factor that could be the solution to the efforts of stake holders in order to mitigate strong heat stress and improve people's living quality in urban areas.

  13. Measurement equipment fitted in light vehicles used for supervision and reconnaissance by the radioprotection service at Cadarache

    International Nuclear Information System (INIS)

    Galanti, A.; Thirion, C.; Grandin, M.

    1967-01-01

    Normally, these vehicles are used to reinforce the atmospheric supervision network based on four fixed stations. In the case of a planned atmospheric discharge they have to control contamination levels and check that these conform to the scattering forecasts. In the case of accidental atmospheric pollution, their role is to rapidly demarcate the pollution zones and to follow the evolution of this pollution. The main measurements carried out are: - Detection of ambient gamma radiation from 10 μrad/hr to 1000 rad/hr. - Detection of the alpha and gamma contamination. - Detection of the beta and gamma contamination of the ground. (authors) [fr

  14. Measurement result of the neutron monitor onboard the Space Environment Data Acquisition Equipment - Attached Payload (SEDA-AP)

    Science.gov (United States)

    Koga, K.; Muraki, Y.; Shibata, S.; Yamamoto, T.; Matsumoto, H.; Okudaira, O.; Kawano, H.; Yumoto, K.

    2013-12-01

    To support future space activities, it is crucial to acquire space environmental data related to the space-radiation degradation of space parts and materials, and spacecraft anomalies. Such data are useful for spacecraft design and manned space activity. SEDA-AP was mounted on 'Kibo' of the ISS (International Space Station) to measure the space environment at a 400-kilometer altitude. Neutrons are very harmful radiation, with electrical neutrality that makes them strongly permeable. SEDA-AP measures the energy of neutrons from thermal to 100 MeV in real time using a Bonner Ball Detector (BBND) and a Scintillation Fiber Detector (FIB). BBND detects neutrons using He-3 counters, which have high sensitivity to thermal neutrons. Neutron energy is derived using the relative response function of polyethylene moderators of 6 different thicknesses. FIB measures the tracks of recoil protons caused by neutrons within a cubic arrayed sensor of 512 scintillation fibers. The charged particles are excluded using an anti-scintillator which surrounds the cube sensor, and the neutron energy is obtained from the track length of a recoil proton. There are three sources of neutrons in space; 1. Albedo Neutrons Produced by reactions of galactic cosmic rays or radiation belt particles with the atmosphere 2. Local Neutrons Produced by the reactions of galactic cosmic rays or radiation belt particles with spacecraft 3. Solar Neutrons Produced by accelerated particles in solar flares An accurate energy spectrum of the solar neutrons includes important information on high-energy particle generation mechanism in a solar flare, because neutrons are unaffected by interplanetary magnetic fields. These data will become useful to forecast solar energetic particles in future. Some candidate events involving solar neutrons were found as a result of analyzing data of the solar flare of M>2 since September 2009. Moreover, it is important to measure albedo neutrons, since protons generated by neutron

  15. Evaluation of knee range of motion: Correlation between measurements using a universal goniometer and a smartphone goniometric application.

    Science.gov (United States)

    Dos Santos, Rafael Aparecido; Derhon, Viviane; Brandalize, Michelle; Brandalize, Danielle; Rossi, Luciano Pavan

    2017-07-01

    Goniometers are commonly used to measure range of motion in the musculoskeletal system. Recently smartphone goniometry applications have become available to clinicians. Compare angular measures using a universal goniometer and a smartphone application. Thirty four healthy women with at least 20° of limited range of motion regarding knee extension were recruited. Knee flexion angles of the dominant limb were measured with a universal goniometer and the ROM © goniometric application for the smartphone. Three trained examiners compared the two assessment tools. Strong correlations were found between the measures of the universal goniometer and smartphone application (Pearson's correlation and interclass correlation coefficient > 0.93). The measurements with both devices demonstrated low dispersion and little variation. Measurements obtained using the smartphone goniometric application analyzed are as reliable as those of a universal goniometer. This application is therefore a useful tool for the evaluation of knee range of motion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Achieving equity within universal health coverage: a narrative review of progress and resources for measuring success.

    Science.gov (United States)

    Rodney, Anna M; Hill, Peter S

    2014-10-10

    Equity should be implicit within universal health coverage (UHC) however, emerging evidence is showing that without adequate focus on measurement of equity, vulnerable populations may continue to receive inadequate or inferior health care. This study undertakes a narrative review which aims to: (i) elucidate how equity is contextualised and measured within UHC, and (ii) describe tools, resources and lessons which will assist decision makers to plan and implement UHC programmes which ensure equity for all. A narrative review of peer-reviewed literature published in English between 2005 and 2013, retrieved from PubMed via the search words, 'universal health coverage/care' and 'equity/inequity' was performed. Websites of key global health organizations were also searched for relevant grey literature. Papers were excluded if they failed to focus on equity (of access, financial risk protection or health outcomes) as well as focusing on one of the following: (i) the impact of UHC programmes, policies or interventions on equity (ii) indicators, measurement, monitoring and/or evaluation of equity within UHC, or (iii) tools or resources to assist with measurement. Eighteen journal articles consisting mostly of secondary analysis of country data and qualitative case studies in the form of commentaries/reviews, and 13 items of grey literature, consisting largely of reports from working groups and expert meetings focusing on defining, understanding and measuring inequity in UHC (including recent drafts of global/country monitoring frameworks) were included. The literature advocates for progressive universalism addressing monetary and non-monetary barriers to access and strengthening existing health systems. This however relies on countries being effectively able to identify and reach disadvantaged populations and estimate unmet need. Countries should assess the new WHO/WB-proposed framework for its ability to adequately track the progress of disadvantaged populations in terms

  17. Feasibility study on equipment of LLW management business system

    International Nuclear Information System (INIS)

    Shimizu, Takafumi

    2010-01-01

    LLW from university and private company has been kept in their own nuclear facilities in Japan. RANDEC has been studying business system for the treatment and conditioning of LLW before disposal. Reference to proven waste treatment process used in Nuclear Power Plant, it was studied that the appropriate treatment process for the LLW from university and private company. The waste will be collected from the university and private company to a central treatment facility. After operations such as unpacking, classification, compression, incineration and others, the waste will be treated to waste form. Most equipment are adopted by the process technology used in Nuclear Power Plant. But some equipment such as measurement of radio activity and solidification of powder need to be studied for the treatment of LLW from university and private company. (author)

  18. Validation of Measured Damping Trends for Flight-Like Vehicle Panel/Equipment including a Range of Cable Harness Assemblies

    Science.gov (United States)

    Smith, Andrew M.; Davis, R. Benjamin; LaVerde, Bruce T.; Fulcher, Clay W.; Jones, Douglas C.; Waldon, James M.; Craigmyle, Benjamin B.

    2012-01-01

    This validation study examines the effect on vibroacoustic response resulting from the installation of cable bundles on a curved orthogrid panel. Of interest is the level of damping provided by the installation of the cable bundles and whether this damping could be potentially leveraged in launch vehicle design. The results of this test are compared with baseline acoustic response tests without cables. Damping estimates from the measured response data are made using a new software tool that leverages a finite element model of the panel in conjunction with advanced optimization techniques. While the full test series is not yet complete, the first configuration of cable bundles that was assessed effectively increased the viscous critical damping fraction of the system by as much as 0.02 in certain frequency ranges.

  19. Development of a universally applicable household food insecurity measurement tool: process, current status, and outstanding issues.

    Science.gov (United States)

    Swindale, Anne; Bilinsky, Paula

    2006-05-01

    The United States Public Law 480 Title II food aid program is the largest U.S. government program directed at reducing hunger, malnutrition, and food insecurity in the developing world. USAID and Title II implementing partners face challenges in measuring the success of Title II programs in reducing household food insecurity because of the technical difficulty and cost of collecting and analyzing data on traditional food security indicators, such as per capita income and caloric adequacy. The Household Food Insecurity Access Scale (HFIAS) holds promise as an easier and more user-friendly approach for measuring the access component of household food security. To support the consistent and comparable collection of the HFIAS, efforts are under way to develop a guide with a standardized questionnaire and data collection and analysis instructions. A set of domains have been identified that is deemed to capture the universal experience of the access component of household food insecurity across countries and cultures. Based on these domains, a set of questions has been developed with wording that is deemed to be universally appropriate, with minor adaptation to local contexts. These underlying suppositions, based on research in multiple countries, are being verified by potential users of the guide. The key remaining issue relates to the process for creating a categorical indicator of food insecurity status from the HFIAS.

  20. Enabling Mobile Communications for the Needy: Affordability Methodology, and Approaches to Requalify Universal Service Measures

    Directory of Open Access Journals (Sweden)

    Louis-Francois PAU

    2009-01-01

    Full Text Available This paper links communications and media usage to social and household economics boundaries. It highlights that in present day society, communications and media are a necessity, but not always affordable, and that they furthermore open up for addictive behaviors which raise additional financial and social risks. A simple and efficient methodology compatible with state-of-the-art social and communications business statistics is developed, which produces the residual communications and media affordability budget and ultimately the value-at-risk in terms of usage and tariffs. Sensitivity analysis provides precious information on bottom-up communications and media adoption on the basis of affordability. This approach differs from the regulated but often ineffective Universal service obligation, which instead of catering for individual needs mostly addresses macro-measures helping geographical access coverage (e.g. in rural areas. It is proposed to requalify the Universal service obligations on operators into concrete measures, allowing, with unchanged funding, the needy to adopt mobile services based on their affordability constraints by bridging the gap to a standard tariff. Case data are surveyed from various countries. ICT policy recommendations are made to support widespread and socially responsible communications access.

  1. Using Overall Equipment Effectiveness indicator to measure the level of planned production time usage of sewing machine

    Directory of Open Access Journals (Sweden)

    Marek Krynke

    2014-12-01

    Full Text Available The chapter presents the results of utilization of the OEE indicator to measure the level of operating time usage of sewing machine production of air bags. The idea of an OEE indictor, which is a key metrics in Total Productive Maintenance (TPM program, is presented. The goals and benefits of its calculation are included. The research object – KL 110 air bags sewing machine - what for the machine is used. The calculation of TPM indicators for the analysed machine is presented. The calculation of TPM indicators was undertaken over a period of six months of the machine’s working time. It was indicated that the overall effectiveness of the machine is at a level of 65,7%, the time losses were 34,3%. Most of the losses were related to low performance. Only Availability indicator reaches a word class level, if other indicators such as Performance, Quality and OEE should be improved, their value should be increased. Activities to improve the effectiveness of the machine utilization were determined.

  2. Measurement invariance of an instrument assessing sustainability of school-based universal behavior practices.

    Science.gov (United States)

    Mercer, Sterett H; McIntosh, Kent; Strickland-Cohen, M Kathleen; Horner, Robert H

    2014-06-01

    The purpose of the study was to examine the extent to which the School-Wide Universal Behavior Sustainability Index: School Teams (SUBSIST; McIntosh, Doolittle, Vincent, Horner, & Ervin, 2009), a measure of school and district contextual factors that promote the sustainability of school practices, demonstrated measurement invariance across groups of schools that differed in length of time implementing school-wide Positive Behavioral Interventions and Supports (PBIS; Sugai & Horner, 2009), student ethnic composition, and student socioeconomic status (SES). School PBIS team members and district coaches representing 860 schools in 14 U.S. states completed the SUBSIST. Findings supported strong measurement invariance, for all items except 1, of a model with two school-level factors (School Priority and Team Use of Data) and 2 district-level factors (District Priority and Capacity Building) across groups of schools at initial implementation, institutionalization, and sustainability phases of PBIS implementation. Schools in the sustainability phase were rated significantly higher on School Priority and Team Use of Data than schools in initial implementation. Strong measurement invariance held across groups of schools that differed in student ethnicity and SES. The findings regarding measurement invariance are important for future longitudinal investigations of factors that may promote the sustained implementation of school practices. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  3. A avaliação do nível de habilidades para trabalhar em equipe entre professores universitários The evaluation of the level of abilities to work in team between university professors

    Directory of Open Access Journals (Sweden)

    Fernanda Pasquoto e Souza

    2007-12-01

    Full Text Available Este estudo procurou avaliar a habilidade para o trabalho em equipe em 78 professores universitários das ciências da saúde e exatas. Utilizou-se o Questionário de Habilidades para Trabalhar em Equipe para avaliar as categorias: preocupação com a equipe, características de liderança, formas de comunicação, preocupação com a tarefa e preocupação com o humano. Realizaram-se análises estatísticas de freqüência e teste t de Student. Nos resultados destaca-se que as habilidades para o trabalho em equipe são positivamente valorizadas no exercício da docência. Nas categorias específicas, preocupação com a tarefa obteve o escore padronizado mais alto, enquanto preocupação com a equipe, o mais baixo. A área das ciências da saúde alcançou resultados mais altos em preocupação com o humano do que a das exatas. Discutem-se aspectos que ratificam a importância da avaliação psicológica nessa área de atuação, contribuindo tanto nas tarefas de diagnóstico como no desenvolvimento dessas habilidades.The purpose of this study was to assess 78 university teachers from the areas of Health Sciences and Natural Sciences in their abilities for teamwork. The Teamwork Abilities Assessment Form was used to assess such categories as: concern with the team, leadership characteristics, ways of communication, concern with the task, and concern with the human aspects. Statistical analysis of frequency and Student's t test were performed. Results have shown that abilities for teamwork are positively assessed in the teaching profession. In the specific categories, concern with the task obtained the highest standardized score, while concern with the team scored lowest. The area of health sciences scored higher than natural sciences regarding concern with the human aspects. Aspects that validate the importance of psychological assessment in this professional area are discussed and contribute not only to the tasks of diagnosis but to the

  4. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  5. Development of a Neutron Long Counter Detector for (α, n) Cross Section Measurements at Ohio University

    Science.gov (United States)

    Brandenburg, Kristyn; Meisel, Zach; Brune, Carl R.; Massey, Thomas; Soltesz, Doug; Subedi, Shiv

    2017-01-01

    The origin of the elements from roughly zinc-to-tin (30 determined. The neutron-rich neutrino driven wind of core collapse supernova (CCSN) is a proposed site for the nucleosynthesis of these elements. However, a significant source of uncertainty exists in elemental abundance yields from astrophysics model calculations due to the uncertainty for (α , n) reaction rates, as most of the relevant cross sections have yet to be measured. We are developing a neutron long counter tailored to measure neutrons for (α , n) reaction measurements performed at The Ohio University Edwards Accelerator Laboratory. The detector design will be optimized using the Monte-Carlo N-Particle transport code (MCNP6). Details of the optimization process, as well as the present status of the detector design will be provided. The plans for first (α , n) cross section measurements will also be briefly discussed. This work was supported in part by the US Department of Energy under Grant Number DE-FG02-88ER40387.

  6. Universal happiness? Cross-cultural measurement invariance of scales assessing positive mental health.

    Science.gov (United States)

    Bieda, Angela; Hirschfeld, Gerrit; Schönfeld, Pia; Brailovskaia, Julia; Zhang, Xiao Chi; Margraf, Jürgen

    2017-04-01

    Research into positive aspects of the psyche is growing as psychologists learn more about the protective role of positive processes in the development and course of mental disorders, and about their substantial role in promoting mental health. With increasing globalization, there is strong interest in studies examining positive constructs across cultures. To obtain valid cross-cultural comparisons, measurement invariance for the scales assessing positive constructs has to be established. The current study aims to assess the cross-cultural measurement invariance of questionnaires for 6 positive constructs: Social Support (Fydrich, Sommer, Tydecks, & Brähler, 2009), Happiness (Subjective Happiness Scale; Lyubomirsky & Lepper, 1999), Life Satisfaction (Diener, Emmons, Larsen, & Griffin, 1985), Positive Mental Health Scale (Lukat, Margraf, Lutz, van der Veld, & Becker, 2016), Optimism (revised Life Orientation Test [LOT-R]; Scheier, Carver, & Bridges, 1994) and Resilience (Schumacher, Leppert, Gunzelmann, Strauss, & Brähler, 2004). Participants included German (n = 4,453), Russian (n = 3,806), and Chinese (n = 12,524) university students. Confirmatory factor analyses and measurement invariance testing demonstrated at least partial strong measurement invariance for all scales except the LOT-R and Subjective Happiness Scale. The latent mean comparisons of the constructs indicated differences between national groups. Potential methodological and cultural explanations for the intergroup differences are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  7. The Gtr-Model a Universal Framework for Quantum-Like Measurements

    Science.gov (United States)

    Aerts, Diederik; Bianchi, Massimiliano Sassoli De

    We present a very general geometrico-dynamical description of physical or more abstract entities, called the general tension-reduction (GTR) model, where not only states, but also measurement-interactions can be represented, and the associated outcome probabilities calculated. Underlying the model is the hypothesis that indeterminism manifests as a consequence of unavoidable uctuations in the experimental context, in accordance with the hidden-measurements interpretation of quantum mechanics. When the structure of the state space is Hilbertian, and measurements are of the universal kind, i.e., are the result of an average over all possible ways of selecting an outcome, the GTR-model provides the same predictions of the Born rule, and therefore provides a natural completed version of quantum mechanics. However, when the structure of the state space is non-Hilbertian and/or not all possible ways of selecting an outcome are available to be actualized, the predictions of the model generally differ from the quantum ones, especially when sequential measurements are considered. Some paradigmatic examples will be discussed, taken from physics and human cognition. Particular attention will be given to some known psychological effects, like question order effects and response replicability, which we show are able to generate non-Hilbertian statistics. We also suggest a realistic interpretation of the GTR-model, when applied to human cognition and decision, which we think could become the generally adopted interpretative framework in quantum cognition research.

  8. Galactically inertial space probes for the direct measurement of the metric expansion of the universe

    International Nuclear Information System (INIS)

    Cagnani, Ivan

    2011-01-01

    Astrometric data from the future GAIA and OBSS missions will allow a more precise calculation of the local galactic circular speed, and better measurements of galactic movements relative to the CMB will be obtained by post-WMAP missions (ie Planck). Contemporary development of high specific impulse electric propulsion systems (ie VASIMIR) will enable the development of space probes able to properly compensate the galactic circular speed as well as the resulting attraction to the centre of our galaxy. The probes would appear immobile to an ideal observer fixed at the centre of the galaxy, in contrast of every other galactic object, which would appear moving according to their local galactic circular speed and their proper motions. Arranging at least three of these galactically static probes in an extended formation and measuring reciprocal distances of the probes over time with large angle laser ranges could allow a direct measurement of the metric expansion of the universe. Free-drifting laser-ranged targets released by the spacecrafts could also be used to measure and compensate solar system's induced local perturbations. For further reducing local effects and increase the accuracy of the results, the distance between the probes should be maximized and the location of the probes should be as far as possible from the Sun and any massive object (ie Jupiter, Saturn). Gravitational waves could also induce random errors but data from GW observatories like the planned LISA could be used to correct them.

  9. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  10. Five-factor personality measures in Chinese university students: effects of one-child policy?

    Science.gov (United States)

    Wang, Wei; Du, Wuying; Liu, Ping; Liu, Jianhui; Wang, Yehan

    2002-01-31

    Since the one-child policy was implemented in China in 1979, many investigators have studied the psychological consequences to children without siblings. Although the results are not conclusive, there is evidence that children who have siblings, rather than only children, have increased anxiety and depression. Whether the differences between students with and without siblings would continue when they reached university age is an interesting question. We used the Zuckerman-Kuhlman Personality Questionnaire to assess personality traits and the Plutchik-van Praag Depression Inventory to measure depressed mood in 134 university students with and 126 university students without siblings. Most students without siblings (93.7%) were reared in urban areas, while 90.3% of students with siblings came from rural areas. Parental professions were higher in social status and annual family incomes were higher in students without siblings. Increased neuroticism-anxiety, aggression-hostility, and depressed mood were found in students with siblings. Gender and annual family income were not significantly related to personality in the two groups, and birth-order position was not related to personality in the students with siblings. In contrast, the depression score was positively correlated with neuroticism-anxiety and aggression-hostility, but negatively correlated with parental occupation and annual family income. The greater competition to receive high education, reduced benefits from society, and lower level of social respect might nurture these personality traits in students with siblings. These findings might, in some limited aspects, indicate that the one-child policy affects personality traits and depressed mood in students with siblings.

  11. Measuring efficiency of university-industry Ph.D. projects using best worst method.

    Science.gov (United States)

    Salimi, Negin; Rezaei, Jafar

    A collaborative Ph.D. project, carried out by a doctoral candidate, is a type of collaboration between university and industry. Due to the importance of such projects, researchers have considered different ways to evaluate the success, with a focus on the outputs of these projects. However, what has been neglected is the other side of the coin-the inputs. The main aim of this study is to incorporate both the inputs and outputs of these projects into a more meaningful measure called efficiency. A ratio of the weighted sum of outputs over the weighted sum of inputs identifies the efficiency of a Ph.D. The weights of the inputs and outputs can be identified using a multi-criteria decision-making (MCDM) method. Data on inputs and outputs are collected from 51 Ph.D. candidates who graduated from Eindhoven University of Technology. The weights are identified using a new MCDM method called Best Worst Method (BWM). Because there may be differences in the opinion of Ph.D. candidates and supervisors on weighing the inputs and outputs, data for BWM are collected from both groups. It is interesting to see that there are differences in the level of efficiency from the two perspectives, because of the weight differences. Moreover, a comparison between the efficiency scores of these projects and their success scores reveals differences that may have significant implications. A sensitivity analysis divulges the most contributing inputs and outputs.

  12. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

    Science.gov (United States)

    Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo

    2016-01-01

    For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.

  13. Dental measurements of Deuteromalayid Javanese students of the Faculty of Dentistry Airlangga University

    Directory of Open Access Journals (Sweden)

    Myrtati Dyah Artaria

    2011-09-01

    Full Text Available Background: Dental anthropology is a new field of study in Indonesia, hence there are few numbers of research that can be found in this field. Knowledge in this field is needed due to the large area and diversity of the people. Moreover, knowledge regarding the possibility to differentiate the sexes of skeletons is still needed for the purpose of identification. Purpose: This research intended to study the differences in mesio-distal measurements of the teeth of Deuteromalayid Javanese males and females studying in the Faculty of Dentistry in Airlangga University. Methods: This study used mesiodistal metric dental data, using dental caliper, to test the existence of sexual dimorphism. Sample were teeth of freshman students of the Airlangga University, from 52 individuals comprising 26 males and 26 females Deuteromalayid originated from Java (Indonesia studying in the Faculty of Dentistry Airlangga University. Measurements were not performed on damaged casts due to caries or other reasons. Differences between males and females were tested using independent t-test. Results: The mean of mesiodistal measurements in males and females differs, where the males have greater size of mesiodistal measurements. The results showed that there were significant differences between sexes in the sample, in all field of teeth except the second upper and lower premolars. Reverse sexual dimorphism-female teeth measurement is larger than those of males-has not been found in these samples. The result of this study revealed that the range of mesiodistal measurements of every tooth in males and females overlapped. Conclusion: It is concluded that teeth measurement of males is bigger than females, except maxillary and mandibular second premolars. Latar belakang: Antropologi dental adalah bidang studi baru di Indonesia, dan karenanya penelitian di bidang ini masih sedikit dijumpai di Indonesia. Apalagi masih dibutuhkan pengetahuan mengenai apakah jenis kelamin dapat

  14. Integration of gamma measuring equipment into an Agusta A109BA helicopter of the Belgian Armed Forces for use in emergency situations

    International Nuclear Information System (INIS)

    Paridaens, J.

    2007-01-01

    In case of a nuclear emergency, accidental releases of radioactive material might cause large scale environmental contamination. After the emergency has been brought under control, and the radioactive releases have settled on the ground, it is essential to map as quickly as possible the extent of the contaminated area and to evaluate the severity of the contamination. Airborne gamma measurements are known to be an effective means for quickly and safely mapping and evaluating large scale contaminations of gamma-emitting radio nuclides. We wanted to integrate gamma measuring equipment, based on a NaI detector, into an Agusta A109BA helicopter of the Belgian armed forces. This was done within the framework of ''Aid to the Nation'', a special program developed by the Belgian Armed Forces for facilitating cooperation between the armed forces and civilian organisations, for projects that are to the benefit of the Belgian Nation. Working in this framework, we also want to develop the necessary procedures that will allow quick and efficient deployment of the measuring capability in case of an emergency

  15. Proposal for a Universal Test Mirror for Characterization of Slope Measuring Instruments

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; McKinney, Wayne R.; Warwick, Tony; Noll, Tino; Siewert, Frank; Zeschke, Thomas; Geckeler, Ralf D.

    2007-01-01

    The development of third generation light sources like the Advanced Light Source (ALS) or BESSY II brought to a focus the need for high performance synchrotron optics with unprecedented tolerances for slope error and micro roughness. Proposed beam lines at Free Electron Lasers (FEL) require optical elements up to a length of one meter, characterized by a residual slope error in the range of 0.1mu rad (rms),and rms values of 0.1 nm for micro roughness. These optical elements must be inspected by highly accurate measuring instruments, providing a measurement uncertainty lower than the specified accuracy of the surface under test. It is essential that metrology devices in use at synchrotron laboratories be precisely characterized and calibrated to achieve this target. In this paper we discuss a proposal for a Universal Test Mirror (UTM) as a realization of a high performance calibration instrument. The instrument would provide an ideal calibration surface to replicate a redundant surface under test of redundant figure. The application of a sophisticated calibration instrument will allow the elimination of the majority of the systematic error from the error budget of an individual measurement of a particular optical element. We present the limitations of existing methods, initial UTM design considerations, possible calibration algorithms, and an estimation of the expected accuracy

  16. Dual-Pump CARS Measurements in the University of Virginia's Dual-Mode Scramjet: Configuration "C"

    Science.gov (United States)

    Cutler, Andrew D.; Magnotti, Gaetano; Cantu, Luca; Gallo, Emanuela; Danehy, Paul M.; Rockwell, Robert; Goyne, Christopher; McDaniel, James

    2013-01-01

    Measurements have been conducted at the University of Virginia Supersonic Combustion Facility in configuration C of the dual-mode scramjet. This is a continuation of previously published works on configuration A. The scramjet is hydrogen fueled and operated at two equivalence ratios, one representative of the scram mode and the other of the ram mode. Dual-pump CARS was used to acquire the mole fractions of the major species as well as the rotational and vibrational temperatures of N2. Developments in methods and uncertainties in fitting CARS spectra for vibrational temperature are discussed. Mean quantities and the standard deviation of the turbulent fluctuations at multiple planes in the flow path are presented. In the scram case the combustion of fuel is completed before the end of the measurement domain, while for the ram case the measurement domain extends into the region where the flow is accelerating and combustion is almost completed. Higher vibrational than rotational temperature is observed in those parts of the hot combustion plume where there is substantial H2 (and hence chemical reaction) present.

  17. The influence of institutional measures and technological proficiency on university teaching through digital platforms

    Directory of Open Access Journals (Sweden)

    Tirado, Ramón

    2012-06-01

    Full Text Available The objective of this study is to empirically test the theoretical model that explains the influence of primary and secondary factors on the integration of digital platforms in university teaching. A sample of 495 teachers from universities in Andalusia completed an online questionnaire that analysed the functions of usage, the digital materials used, the didactic and technological competence of the teaching staff, the support measures adopted by the institutions and the effect on teaching of platform use. Prior factor analysis and the application of the Amos program enabled us to develop a structural equation model to corroborate the indirect influence of the support measures and institutional recognition on teachers in their use of the platforms, and the direct influence of the teachers’ technological proficiency. Este estudio tiene como objetivo poner a prueba empíricamente el modelo teórico que explica la influencia de los factores de primer y segundo orden sobre la integración de las plataformas digitales en la docencia universitaria. Para ello, sobre una muestra de 495 profesores universitarios andaluces, se aplica un cuestionario online que analiza las funciones de uso, materiales digitales utilizados, competencia didáctica y tecnológica del profesorado, medidas de impulso institucionales, y efectos didácticos del uso. El análisis factorial previo y la aplicación del programa Amos permite la elaboración un modelo de ecuación estructural que corrobora la influencia indirecta de las medidas de apoyo y el reconocimiento institucional sobre los efectos didácticos del uso de plataformas, así como la influencia directa de la competencia tecnológica del profesorado.

  18. Performance management of nuclear medical apparatuses in Osaka University Hospital

    International Nuclear Information System (INIS)

    Ikehara, Katsuhiro; Kusumi, Yoshimi; Hayashi, Makoto; Miharu, Tomoyoshi; Masuda, Kazutaka

    1975-01-01

    Nuclear medical out side-body measuring equipments in Osaka University Hospital consist of scinticamera, scintiscanner and movement-measuring equipment as measuring equipments, and central processing equipment, CRT attached with Polaroid camera, data typewriter, X-Y recorder, and high speed tape reader as data processing equipments. Daily and monthly management items are set up to maintain the best function of these equipments. The data processing room is air-conditioned to keep temperature at 25 0 C and humidity at 60% constantly, and they are confirmed with a temperature and humidity self-recorder. Computer system is used for the homogeneity control and the correction to counting failure of the scinticamera. As the repair of nuclear medical apparatuses needs long period and because of the special circumstances of radioactive drugs, very close cooperation among technicians, doctors and equipment makers is required. (Kobatake, H.)

  19. Measurement of radioactivity in air at the linear accelerator of Kyoto University reactor facility

    International Nuclear Information System (INIS)

    Ikebe, Yukimasa; Shimo, Michikuni

    1976-01-01

    It is well-known that the induced activities from a number of nuclides are generated in air during the operation of high energy accelerators. Of these, measurements were performed with the linear accelerator of Kyoto University reactor facility for the purpose of the clarification of the production mechanism and behavior of radioactive aerosols. The concentration in air and the size distribution of 13 N aerosols which have aerosols as the carrier among 13 N produced by the γ-n reaction of 14 N were measured with filter packs and by diffusion method, respectively. The density of number and size distribution of non-radioactive aerosols were measured to understand the production mechanism and behavior of 13 N aerosols. For the aerosol number density, Aitken nucleus number was measured with a Pollak counter. The results obtained show that (1) under the operating condition of the linear accelerator at that measurement time, 13 N aerosol concentration was (2 to 50) x 10 -13 Ci/cm 3 while 13 N gas component concentration was (1 to 25) x 10 -12 Ci/cm 3 , i.e. the ratio was approximately 1 : 10 (2) the average size of 13 N aerosols was 0.01 to 0.04 μm, and it was found that there was positive correlation to relative humidity; (3) during the operation of the accelerator, the generation of aerosols 10 to 100 times as much as the background level was observed. The size distribution of aerosols showed a peak around 0.01 μm; and others. Examination was carried out regarding a 13 N aerosol production model based on the sticking of aerosol-free 13 N to aerosols. (Wakatsuki, Y.)

  20. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  1. Managerial Systems as Measures of Quality Management in Universities in Uganda

    Science.gov (United States)

    Neema-Abooki, P.

    2014-01-01

    This paper envisions that, since universities are basically consent organizations university management has an obligation to processes that engender total participation and passion of all employees. This study aimed at delving into management stances at universities. It based on Likert's systems of management, which depict the total organization…

  2. Geneva University - Measurement of the Lamb shift in muonic hydrogen: the proton radius puzzle

    CERN Multimedia

    2010-01-01

    GENEVA UNIVERSITY École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 GENEVA 4 Tel: (022) 379 62 73 Fax: (022) 379 69 92 Wednesday 12 May 2010 PARTICLE PHYSICS SEMINAR at 17.00 hrs – Stückelberg Auditorium Measurement of the Lamb shift in muonic hydrogen: the proton radius puzzle Dr Aldo Antogninia , CREMA Collaboration, Max Planck Institute, Germany At the Paul Scherrer Institut, Switzerland, we have measured several 2S-2P transition frequencies in muonic hydrogen (µp) and deuterium (µd) by means of laser spectroscopy. This results in an order of magnitude improvement on the rms charge radius values of the proton and the deuteron. Additionally the Zemach radii and the deuteron polarizability are also inferred. The new proton radius value is deduced with a relative accuracy of 0.1% but strongly disagrees from CODATA. The origin of this discrepancy is not yet known. It may come from theo...

  3. Measurements of environmental background radiation levels by TLD in and around the Jahangirnagar University Campus

    International Nuclear Information System (INIS)

    Mollah, A.S.; Aleya Begum; Idris Miah, M.; Yunus, Afrozi

    1997-01-01

    The background radiation levels at 30 locations in and around the Jahangirnagar University Campus (JUC) were measured using a LiF(TLD-100) thermoluminescent dosimeter (TLD). In addition, dose rates at three pre-selected locations were measured on a monthly as well as quarterly basis for one year period (July 1993 - June 1994). The dose rate ranges from 1016 to 2167 μSv.y -1 (101.6 to 216.7 mrem.y -1 ) with a mean value of 1595 μSv.y -1 (159.5 mrem.y -1 ). These values are comparable with those of pre- and post-operational values for the reactor site. The estimated average annual effective dose equivalent to the inhabitants at the study areas was found to be 1276 μSv (127.6 mrem). Variation of background radiation level with meteorological parameters, namely, temperature, rainfall, relative humidity and pressure was also studied. The influence on the dose rate of the meteorological parameters was observed. (author)

  4. Establishment of hybridized focus measure functions as a universal method for autofocusing

    Science.gov (United States)

    Shah, Mohammad Imran; Mishra, Smriti; Rout, Chittaranjan

    2017-12-01

    Exact focusing is essential for any automatic image capturing system. Performances of focus measure functions (FMFs) used for autofocusing are sensitive to image contents and imaging systems. Therefore, identification of universal FMF assumes a lot of significance. Eight FMFs were hybridized in pairs of two and implemented simultaneously on a single stack to calculate the hybrid focus measure. In total, 28 hybrid FMFs (HFMFs) and eight FMFs were implemented on stacks of images from three different imaging modalities. Performance of FMFs was found to the best at 50% region sampling. Accuracy, focus error, and false maxima were calculated to evaluate the performance of each FMF. Nineteen HFMFs provided >90% accuracy. Image distortion (noise, contrast, saturation, illumination, etc.) was performed to evaluate robustness of HFMFs. Hybrid of tenengrad variance and steerable filter-based (VGRnSFB) FMFs was identified as the most robust and accurate function with an accuracy of ≥90% and a relatively lower focus error and false maxima rate. Sharpness of focus curve of VGRnSFB along with eight individual FMFs was also computed to determine the efficacy of HFMF for the optimization process. VGRnSFB HFMF may be implemented for automated capturing of an image for any imaging system.

  5. Reactivity worth measurement of the control blades of the University of Florida training reactor

    International Nuclear Information System (INIS)

    Quintero-Leyva, Barbaro

    1997-01-01

    A series of experiments were carried out in order to measure the reactivity worth of the safety and regulating blades of the University of Florida Training Reactor (UFTR) using the Inverse Kinetics, the Inverse Kinetics-Rod Drop method and the Power Ratio. The reactor's own instrumentation (compensated ion chamber) and an independent counting system (fission chamber) were used. A very smooth exponential decay of the flux was observed after 6s of the beginning of the transients using the reading of the reactor detector. The results of the measurements of the reactivity using both detectors were consistent and in good agreement. The compensated ion chamber showed a very smooth exponential behavior; this suggests that if we could record the power for a small sample time, say 0.1 s from the beginning of the transient, several additional research projects could be accomplished. First, precise intercomparison of the methods could be achieved if the statistics level is acceptable. Second, a precise description of the bouncing of the blades and its effects on the reactivity could be achieved. Finally, the design of a reactivity-meter could be based on such study. (author)

  6. Overall Equipment Effectiveness Implementation Criteria

    Science.gov (United States)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  7. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  8. Low level photoneutron detection equipment

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Yuqin; Li Yuansui

    1991-01-01

    A low level photoneutron detection equipment has been developed. The photoneutrons produced by interaction of 226 Ra gamma quanta and deutron (D) target are detected with n-n discrimination detector made up of 3 He proportional counter array. The D-content information in the target can be obtained from the measured photoneutron counts. The equipment developed is mainly used for nondestructive D-content measurement of D-devices

  9. Comparison of direct inter-filament resistance measurement on Nb3Sn strands between University of Twente and ENEA

    NARCIS (Netherlands)

    Zhou, Chao; Dhalle, Marc M.J.; Nijhuis, Arend; Breschi, M.; Spina, T.; Della Corte, A.; Corato, V.

    2013-01-01

    Experimental results of interfilament resistance measurements obtained with different facilities are compared. Two internal tin Nb3Sn strand types are tested at the University of Twente (UT) and ENEA Frascati. The direct interfilament resistance is measured with a standard four-point voltage-current

  10. Measurement and Comparison of Variance in the Performance of Algerian Universities using models of Returns to Scale Approach

    Directory of Open Access Journals (Sweden)

    Imane Bebba

    2017-08-01

    Full Text Available This study aimed to measure and compare the performance of forty-seven Algerian universities, using models of returns to Scale approach, which is based primarily on the Data Envelopment Analysis  method. In order to achieve the objective of the study, a set of variables was chosen to represent the dimension of teaching. The variables consisted of three input variables, which were:  the total number of students  in the undergraduate level, students in the post graduate level and the number of permanent professors. On the other hand, the output variable was represented by the total number of students holding degrees of the two levels. Four basic models for data envelopment analysis method were applied. These were: (Scale Returns, represented by input-oriented and output-oriented constant returns and input-oriented and output-oriented  variable returns. After the analysis of data, results revealed that eight universities achieved full efficiency according to constant returns to scale in both input and output orientations. Seventeen universities achieved full efficiency according to the model of input-oriented returns to scale variable. Sixteen universities achieved full efficiency according to the model of output-oriented  returns to scale variable. Therefore, during the performance measurement, the size of the university, competition, financial and infrastructure constraints, and the process of resource allocation within the university  should be taken into consideration. Also, multiple input and output variables reflecting the dimensions of teaching, research, and community service should be included while measuring and assessing the performance of Algerian universities, rather than using two variables which do not reflect the actual performance of these universities. Keywords: Performance of Algerian Universities, Data envelopment analysis method , Constant returns to scale, Variable returns to scale, Input-orientation, Output-orientation.

  11. Dark Skies as a Universal Resource: Citizen Scientists Measuring Sky Brightness

    Science.gov (United States)

    Walker, C. E.; Isbell, D.; Pompea, S. M.

    2007-12-01

    The international star-hunting event known as GLOBE at Night returned March 8-21, 2007 in two flavors: the classic GLOBE at Night activity incorporating unaided-eye observations which debuted last year, and a new effort to obtain precise measurements of urban dark skies using digital sky-brightness meters. Both flavors of the program were designed to aid in heightening the awareness about the impact of artificial lighting on local environments, and the ongoing loss of a dark night sky as a natural resource for much of the world's population. To make possible the digital GLOBE at Night program, NSF funded 135 low-cost, digital sky-quality meter (manufactured by Unihedron). With these, citizen-scientists took direct measurements of the integrated sky brightness across a wide swath of night sky. Along with related materials developed by the National Optical Astronomy Observatory (NOAO), the meters were distributed to citizen-scientists in 21 U.S. states plus Washington DC, and in 5 other countries, including Chile, where NOAO has a major observatory. The citizen- scientists were selected from teachers, their students, astronomers at mountain-top observatories, International Dark-Sky Association members and staff from 19 small science centers. Most sites had a coordinator, who instructed local educators in the proper use of the meters and develop a plan to share them as widely as possible during the 2-week window. The local teams pooled their data for regional analysis and in some cases shared the results with their schools and local policymakers. Building upon the worldwide participation sparked by the first GLOBE at Night campaign in March 2006, the observations this year approached 8500 (from 60 countries), 85% higher than the number from last year. The success of GLOBE at Night 2007 is a major step toward the International Year of Astronomy in 2009, when one goal is to make the digital data collection into a worldwide activity. In this presentation, we will outline

  12. Coal ash monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, C G; Wormald, M R

    1978-10-02

    The monitoring equipment is used to determine the remainder from combustion (ash slack) of coal in wagons designed for power stations. Next to the rails, a neutron source (252 Cf, 241 Am/Be) is situated, which irradiates the coal with neutrons at a known dose, which produces the reaction 27 Al (n ..gamma..) Al 28. The aluminium content is a measure of the remainder. The 1.78 MeV energy is measured downstream of the rail with a detector. The neutron source can only act in the working position of a loaded wagon.

  13. THE PERFORMANCE OF SERVQUAL TO MEASURE SERVICE QUALITY IN PRIVATE UNIVERSITY

    OpenAIRE

    Leonnard

    2018-01-01

    The increasing number of educational services has caused a high competition in this industry. In Indonesia, the number of private universities is the highest compared to state universities and other forms of higher education institutions. Ability to predict factors that are important in providing educational services to achieve student satisfaction and make them loyal to the university is highly necessary. In this study, we investigated the main factors of service quality that affect student ...

  14. [An assessment of the Dundee Ready Education Environment Measure (DREEM) in Chilean university students].

    Science.gov (United States)

    Ortega B, Javiera; Pérez V, Cristhian; Ortiz M, Liliana; Fasce H, Eduardo; McColl C, Peter; Torres A, Graciela; Wright, Ana; Márquez U, Carolina; Parra P, Paula

    2015-05-01

    The entry to a University requires an adaptation process that not all students solve with the same kind of success. Even though students social adaptation and emotional skills are essential, the educational environmental that they perceive has a significant influence in their academic life. To describe the changes in the perception about academic environment that medical students experience during the first three years of undergraduate career. The Dundee Ready Education Environment Measure (DREEM) scale was applied to 525 first to third year medical students and an exploratory factorial analysis was made. Four factors were identified: Academic Perception: academic quality that students attribute to the process in which they take part, as well as to the assessment that they do of their learning outcomes (coefficient ± = 0.85); Academic Experience: refers to positive emotions that students experience during the career such as confidence, pleasure and energy (coefficient ± = 0.76); Atmosphere Perception, comfort and calm that students experiment during their academic activities (coefficient ± = 0.79); Teachers Perception: the perception that students have of teachers about their interest and disposition towards students (coefficient ± = 0.50). The assessment of academic environment quality is inversely associated with the lapse that the students have spent in their undergraduate careers.

  15. THE CORRELATION BETWEEN STUDENTS’ LEARNING STYLES AND PARENTS’ ATTENTION WITH MEASURING EQUIPMENT ACHIEVEMENT OF THE TENTH GRADE STUDENTS OF AUTOMOTIVE ENGINEERING EXPERTISE PROGRAM OF STATE VOCATIONAL HIGH SCHOOL PIRI SLEMAN IN THE ACADEMIC YEAR 2013/2014

    Directory of Open Access Journals (Sweden)

    Moh. Sulhan Haidi

    2014-12-01

    Full Text Available This research is aimed at finding out (1 the correlation  between students’ learning styles and measuring equipment achievement of the tenth grade students of Automotive Engineering Expertise Program of State Vocational High School Piri Sleman in the academic year 2013/2014; (2 the correlation between parents’ attention with measuring equipment achievement of the tenth grade students of Automotive Engineering Expertise Program of State Vocational High School Piri Sleman in the academic year 2013/2014; (3 the correlation between students’ learning styles and parents’ attention with measuring equipment achievement of the tenth grade students of Automotive Engineering Expertise Program of State Vocational High School Piri Sleman in the Academic Year 2013/2014. The kind of this research is correlation study and categorized as ex post facto. The population of the research was 105 students while the sample was 82 students counted from Isaac and Michael formula. The technique of sampling used in this research was simple random sampling. The technique of the data collection was questionnaire and documentation. Item validity was computed from product moment correlation. Item reliability was calculated by using alpha formula. The technique of data analysis used in this study was partial correlation and doubled correlation analyses. Precondition testing analysis (normality, linearity, and multi co linearity testing, Based on the data analysis, the results were as follows: (1 there is a positive and significant correlation between students’ learning styles (X1 and measuring equipment achievement (Y; (2 there is a positive and significant correlation between parents’ attention (X2 with measuring equipment achievement (Y; (3 there is a positive and significant correlation between students’ learning styles (X1 and parents’ attention (X2 with measuring equipment achievement (Y.

  16. A Pilot Study on Measuring the Readers’ Emotions Using HRV Biofeedback at University Malaysia Pahang

    Directory of Open Access Journals (Sweden)

    Iftikhar Yousaf

    2016-11-01

    Full Text Available Positive associations have been found between reading and emotions. Various techniques, including traditional as well as modern, have been used to measure emotions in the previous studies. However, emotional measurement of the readers of a literary piece through HRV Biofeedback has never been investigated. A study was undertaken to assess whether Heart Rate Variability (HRV biofeedback regarding  measurement of emotions in the readers of English Literature is likely to be effective or not for the first time at University Malaysia Pahang. In this study two scripts of the plays “Dr. Faustus” and “Waiting for Godot” were used. The Scripts were prepared from the Original Texts of these two plays, which might convey the overall message of the plays to the readers and resultantly produce the desired effect on the readers’ emotions. The total words of these two scripts were around 1050 each, allowing the students to complete one script in 7-8 minutes. Six subjects were selected randomly. While they were sitting calm and quiet at the desk, photoplethysmograph sensor was attached to their one of the earlobes which was connected to the emWave Desktop-PC software to record their Baseline HRV. The subjects, one at a time, read the Script 1 “Waiting for Godot” silently. After completion of the reading of Script 1, the emWave software was stopped and the HRV of the subject was recorded and saved automatically in the computer. The same process was repeated with Script 2 “Dr. Faustus”. In this way, emWave software recorded three HRV data for every subject. Results show obvious changes and significant correlations in the HRV of the participants while reading both the scripts. VLF increased for Script 1 while it decreased for Script 2. On the other hand, HF increased for Script 1 and further increased for Script 2.  LF decreased for Script 1 and increased for Script 2. These results point out the tendency that the stress level of the

  17. Evaluating and Quantifying User and Carer Involvement in Mental Health Care Planning (EQUIP: Co-Development of a New Patient-Reported Outcome Measure.

    Directory of Open Access Journals (Sweden)

    Penny Bee

    Full Text Available International and national health policy seeks to increase service user and carer involvement in mental health care planning, but suitable user-centred tools to assess the success of these initiatives are not yet available. The current study describes the development of a new reliable and valid, interval-scaled service-user and carer reported outcome measure for quantifying user/carer involvement in mental health care planning. Psychometric development reduced a 70-item item bank to a short form questionnaire using a combination of Classical Test, Mokken and Rasch Analyses. Test-retest reliability was calculated using t-tests of interval level scores between baseline and 2-4 week follow-up. Items were worded to be relevant to both service users and carers. Nine items were removed following cognitive debriefing with a service user and carer advisory group. An iterative process of item removal reduced the remaining 61 items to a final 14-item scale. The final scale has acceptable scalability (Ho = .69, reliability (alpha = .92, fit to the Rasch model (χ2(70 = 97.25, p = .02, and no differential item functioning or locally dependent items. Scores remained stable over the 4 week follow-up period, indicating good test-retest reliability. The 'Evaluating the Quality of User and Carer Involvement in Care Planning (EQUIP' scale displays excellent psychometric properties and is capable of unidimensional linear measurement. The scale is short, user and carer-centred and will be of direct benefit to clinicians, services, auditors and researchers wishing to quantify levels of user and carer involvement in care planning.

  18. Measurement of Student Satisfaction as an Important Input for Strategic Planning: A Case from Dokuz Eylül University

    Directory of Open Access Journals (Sweden)

    Aysun KAPUCUGİL İKİZ

    2017-04-01

    Full Text Available For the purpose of providing a better quality of service for their students, higher education institutions develop both academic and social strategies that will meet students’ expectations, and they can monitor the performance of the related activities efficiently by integrating them into their strategic plans. Although students’ expectations from the institutions in which they are registered can be provided directly through feedback mechanisms, there is a need for a sustainable system through which students’ opinions on all of the services are gathered in a systematic way. In this regard, the objective of this study was to design an information system measuring the satisfaction level of the students about the services/ facilities provided by the university on a regular basis and reporting the results of the measurement to the university management in a certain format. In this descriptive research that was carried out within the scope of Dokuz Eylul University quality assessment, evaluation and assurance activities in higher education, an electronic form was developed which was integrated into the Dokuz Eylul University Information System. Through this form, particular questions were asked covering many service dimensions, i.e., infrastructure facilities, the provided services, educational and career development, approaches of the university towards the students, communication with students, attitudes of students towards the university, etc. The evaluations of students’ feedback were performed based on descriptive statistics, and an additional assessment scale was also generated to classify and order the overall satisfaction levels as primary priority to improve, secondary priority to improve, opportunities available, and the areas where the university is strong. This system helped to make decisions for the improvements in required fields, generated inputs to the strategic plan of Dokuz Eylul University for determining policies and goals

  19. Reviews Book: The Age of Wonder Equipment: Portoscope DVD: Around the World in 80 Images Book: Four Laws that Drive the Universe Book: Antimatter Equipment: Coffee Saver Starter Set Equipment: Graphite Levitation Kit Book: Critical Reading Video: Science Fiction-Science Fact Web Watch

    Science.gov (United States)

    2009-03-01

    WE RECOMMEND The Age of Wonder This book tells the stories of inspiring 19th-century scientists Antimatter A fast read that gives an intriguing tour of the antimatter world Science Fiction-Science Fact A video from a set of resources about the facts in science fiction WORTH A LOOK Portoscope Lightweight ×30 microscope that is easy on the purse Four Laws that Drive the Universe In just 124 pages Peter Atkins explains thermodynamics Coffee Saver Starter Kit A tool that can demonstrate the effect of reduced air pressure Graphite Levitation Kit Compact set that demonstrates diamagnetic behaviour Critical Reading A study guide on how to read scientific papers HANDLE WITH CARE Around the World in 80 Images Navigate through images from Envistat, country by country WEB WATCH This month's issue features real-time simulation program Krucible 2.0, which enables learners to run virtual experiments

  20. Mine railway equipments management information system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.; Han, K.; Duan, T.; Liu, Z.; Lu, H. [China University of Mining and Technology, Xuzhou (China)

    2007-06-15

    Based on client/server and browser/server models, the management information system described realized the entire life-cycle management of mine railway equipment which included universal equipment and special equipment in the locomotive depot, track maintenance division, electrical depot and car depot. The system has other online functions such as transmitting reports, graphics management, statistics, searches, graphics wizard and web propaganda. It was applied in Pingdingshan Coal Co. Ltd.'s Railway Transport Department. 5 refs., 4 figs.

  1. Educational experiment for university students using natural radioactivity. Development of an additional experiment to measure the increase in 214Pb and 214Bi produced from 222Rn

    International Nuclear Information System (INIS)

    Nakamura, Mariko; Esaka, Takao; Kamata, Masahiro

    2005-01-01

    Although several works have been published to date regarding radiochemistry, most of them have been designed for those who major in subjects related to chemistry or physics and use rather sophisticated methods and apparatus. Education about radiation and radioactivity is also very important for other students because a basic knowledge of radiation and radioactivity is indispensable for understanding environmental problems or energy problems in the future. However, it is not easy to conduct practical work using radioactivity in students' experiments at school or at university because the use of radioactivity is strictly regulated by the law, and equipment such as radiation counters is too expensive for school budgets. From such a viewpoint, we developed several kinds of safe and inexpensive experiments for education using natural radioactivity so that university (or senior high school) students can learn through their practical work without being regulated by the law. For this purpose, radioactive species belonging to the uranium decay series are suitable because these species can be easily obtained from mineral spring water or soil samples. In addition, some of the species such as 214 Pb and 214 Bi emit beta rays, which are easy to detect, and the half-lives of these which are easy to detect, and the half-lives of these elements can be measured in one or two-hour school activities. This kind of experiment was employed as an ''Educational experiment for radiochemistry'' at Tottori University for nearly fifty students every year. Although the experiment itself was essentially complete, the students did not have the chance to observe how radioactive equilibrium was established. Therefore, we have developed an additional work plan to enable students to observe how 214 Pb and 214 Bi are produced from 222 Rn, and have made this experiment more complete. The educational usefulness of this additional experiment was evaluated and will be presented in section 5. (author)

  2. ANALYSIS OF MEASURES FOR INCREASING THE RATING OF UNIVERSITY IN INTERNATIONAL RATING SYSTEM

    Directory of Open Access Journals (Sweden)

    В.П. Харченко

    2011-02-01

    Full Text Available The principles of forming the world's most popular international Internet-ranking of universities are considered. The principles of forming the international rating of electronic resources known as Webometrics, which results are defined by summing four values based on quantity of unique external links to the site page and by the quantity of “valuable” files placed on website are represented.  Мost Internet ratings make slope on the  Web activity of the university and its researchers, therefore the participation of entire staff at university is required

  3. Measuring macro-level effects of the global economic recession on university-industry research cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Azagra-Caro, J.M.; Tijssen, R.J.W.; Yegros-Yegros, A.

    2016-07-01

    The 2007/2008 financial crisis, and ensuing economic recession, had a direct negative effect on university-industry research cooperation in the OECD countries and other economies – it diminished the number of university-industry co-authored research publications (UICs) during the period 2008-13 by 7%. It also changed the relationship between national business expenditure on R&D and UIC output levels. Before the recession the relationship was negative, but became positive during the years 2008-2013. The few countries where business expenditure on R&D increased during recession saw UIC numbers rise. This moderating effect of the recession applies only to ‘domestic UICs’, where universities cooperated with business companies located in the same country. Micro-level research is needed to assess the contributing effects on large university-industry R&D consortia on both domestic and international collaboration patterns. (Author)

  4. Field measurements of mixed exposure of operators to radioactive aerosol, gas and quartz in confinement of mining equipment cabs during open-pit mining of high-grade uranium ores

    International Nuclear Information System (INIS)

    Yoshida, K.; Atiemo, M.A.; Markham, J.W.

    1982-07-01

    A series of field measurements of miners mixed exposure to radon and daughters, uranium ore dust and respirable quartz, was conducted in an open-pit mine in Northern Saskatchewan during 1980-81. Control of radon gas levels in the mining equipment cabs is required. Dust may be reduced by minimizing the resuspension of dust from contaminated surfaces within the cabs

  5. General Education Courses at the University of Botswana: Application of the Theory of Reasoned Action in Measuring Course Outcomes

    Science.gov (United States)

    Garg, Deepti; Garg, Ajay K.

    2007-01-01

    This study applied the Theory of Reasoned Action and the Technology Acceptance Model to measure outcomes of general education courses (GECs) under the University of Botswana Computer and Information Skills (CIS) program. An exploratory model was validated for responses from 298 students. The results suggest that resources currently committed to…

  6. Another donation of computer equipment

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On Thursday 27 February, CERN was pleased to donate computer equipment to a physics institute in the Philippines.   H.E. Leslie J. Baja and Rolf Heuer. Following donations of computer equipment to institutes in Morocco, Ghana, Bulgaria, Serbia and Egypt, CERN is to send 50 servers and 4 network switches to the National Institute of Physics at the University of the Philippines Diliman. CERN’s Director-General Rolf Heuer and the Ambassador of the Philippines to Switzerland and Lichtenstein, H.E. Leslie J. Baja, spoke of their enthusiasm for the project during an official ceremony. The equipment will be used for various high energy physics research programmes in the Philippines and for the University’s development of digital resources for science.

  7. Scientific Equipment Division - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2001-01-01

    . The machine allows the following tool movements in particular axes: X - 1000 mm, Y- 500 mm, Z - 500 mm; it is controlled by HEIDENHAIN 407 Control System, and ensures the accuracy and reproducibility of machining of 0.01 mm in each of the axis. In 2000, the Department of Mechanical Construction designed, manufactured and assembled an equipment for the following foreign laboratories: - Deutches Elektronen Synchrotron, Hamburg, FRG; - Forschungszentrum Karlsruhe, FRG; - Institute of Physics, Polish Academy of Sciences, Warsaw, Poland; - Jagiellonian University, Cracow, Poland; - Massachusetts Institute of Technology, Cambridge, Massachusetts, USA; - Brookhaven National Laboratory, Upton, NY, USA. Besides the large designs and systems described below, some interesting works were made for the departments of our Institute and other institutions: 1. Design and manufacturing of the new photon calorimeter of Luminosity Monitor for ZEUS Experiment at DESY; 2. Final installation of Detector Enclosures and Dry Air System for PHOBOS Experiment at BNL; 3. Design and manufacturing of the shutter and manufacturing of supporting structures for AUGER Project in Argentina; 4. Manufacturing and installation of Deflectors I and II for cyclotron AIC-144 at our Institute; 5. Design and manufacturing of resonator joggle for cyclotron AIC-144 at our Institute; 6. Upgrade of outlet chamber of for cyclotron AIC-144 at our Institute. (author)

  8. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-01-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr 3 (Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  9. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment, developed for the renewal of the network of automatic stations for environmental radiological surveillance of the Generalitat de Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2013-01-01

    The renewal of the automatic environmental radiation surveillance network of the Gereralitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. The monitors use scintillation cristals, either NaI(Tl) or LaBr 3 (Ce) and currently, there are 3 types of equipment: water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentrations for some isotopes

  10. Percentage-based Author Contribution Index: a universal measure of author contribution to scientific articles.

    Science.gov (United States)

    Boyer, Stéphane; Ikeda, Takayoshi; Lefort, Marie-Caroline; Malumbres-Olarte, Jagoba; Schmidt, Jason M

    2017-01-01

    Deciphering the amount of work provided by different co-authors of a scientific paper has been a recurrent problem in science. Despite the myriad of metrics available, the scientific community still largely relies on the position in the list of authors to evaluate contributions, a metric that attributes subjective and unfounded credit to co-authors. We propose an easy to apply, universally comparable and fair metric to measure and report co-authors contribution in the scientific literature. The proposed Author Contribution Index (ACI) is based on contribution percentages provided by the authors, preferably at the time of submission. Researchers can use ACI to compare the contributions of different authors, describe the contribution profile of a particular researcher or analyse how contribution changes through time. We provide such an analysis based on contribution percentages provided by 97 scientists from the field of ecology who voluntarily responded to an online anonymous survey. ACI is simple to understand and to implement because it is based solely on percentage contributions and the number of co-authors. It provides a continuous score that reflects the contribution of one author as compared to the average contribution of all other authors. For example, ACI(i) = 3, means that author i contributed three times more than what the other authors contributed on average. Our analysis comprised 836 papers published in 2014-2016 and revealed patterns of ACI values that relate to career advancement. There are many examples of author contribution indices that have been proposed but none has really been adopted by scientific journals. Many of the proposed solutions are either too complicated, not accurate enough or not comparable across articles, authors and disciplines. The author contribution index presented here addresses these three major issues and has the potential to contribute to more transparency in the science literature. If adopted by scientific journals, it

  11. Shaking table testing of electrical equipment in Argentina

    International Nuclear Information System (INIS)

    Carmona, J.S.; Zabala, F.; Santalucia, J.; Sisterna, C.; Magrini, M.; Oldecop, L.

    1995-01-01

    This paper describes the testing facility, the methodology applied and the results obtained in the seismic qualification tests of different types of electric equipment. These tests were carried out on a shaking table that was developed and built at the Earthquake Research Institute of the National University of San Juan, Argentine. The equipment tested consist of 500 KV and 132 KV current transformers, a 500 KV voltage transformer, a 145 KV disconnecter and a relay cabinet. The acceleration response of the tested equipment was measured at several locations distributed along its height, and strains were measured at critical points by strain gauges cemented on the base of the porcelain insulator. All the information was recorded with a data acquisition system at a sampling rate of 200 times per second in each channel. The facility developed at this Institute is the largest one in operation in Argentina at present and the equipment tested is the highest, heaviest and more slender one which has been seismically qualified on a shaking table in this country. These tests have been a valuable experience in the field of structural dynamic testing applied to equipment of hydroelectric and nuclear power plants. (author)

  12. Universal control and measuring system for modern classic and amorphous magnetic materials single/on-line strip testers

    Science.gov (United States)

    Zemánek, Ivan; Havlíček, Václav

    2006-09-01

    A new universal control and measuring system for classic and amorphous soft magnetic materials single/on-line strip testing has been developed at the Czech Technical University in Prague. The measuring system allows to measure magnetization characteristic and specific power losses of different tested materials (strips) at AC magnetization of arbitrary magnetic flux density waveform at wide range of frequencies 20 Hz-20 kHz. The measuring system can be used for both single strip testing in laboratories and on-line strip testing during the production process. The measuring system is controlled by two-stage master-slave control system consisting of the external PC (master) completed by three special A/D measuring plug-in boards, and local executing control unit (slave) with one-chip microprocessor 8051, connected with PC by the RS232 serial line. The "user friendly" powerful control software implemented on the PC and the effective program code for the microprocessor give possibility for full automatic measurement with high measuring power and high measuring accuracy.

  13. NOTE FOR EDITOR: Development An Instrument To MeasureUniversity Students' Attitude Towards E-Learning

    OpenAIRE

    MEHRA, Vandana; OMIDIAN, Faranak

    2015-01-01

    The study of student’s attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students’ attitude towards e-learning. The scale was administered to 200 University students from two countries (India and Iran) .The 83-item attitude towards e-learning scale was developed on six domains as Perceived usefulness ; Intention to adopt e-learning ; Ease...

  14. NOTE FOR EDITOR: Development An Instrument To MeasureUniversity Students' Attitude Towards E-Learning

    OpenAIRE

    MEHRA, Vandana; OMIDIAN, Faranak

    2012-01-01

    The study of student’s attitude towards e-learning can in many ways help managers better prepare in light of e-learning for the future. This article describes the process of the development of an instrument to measure university students’ attitude towards e-learning. The scale was administered to 200 University students from two countries (India and Iran) .The 83-item attitude towards e-learning scale was developed on six domains as Perceived usefulness ; Intention to adopt e-learning ; Ease...

  15. Measuring growth index in a universe with massive neutrinos: A revisit of the general relativity test with the latest observations

    Science.gov (United States)

    Zhao, Ming-Ming; Zhang, Jing-Fei; Zhang, Xin

    2018-04-01

    We make a consistency test for the general relativity (GR) through measuring the growth index γ in a universe with massive (sterile/active) neutrinos. We employ the redshift space distortion measurements to do the analysis. To constrain other cosmological parameters, we also use other cosmological measurements, including the Planck 2015 cosmic microwave background temperature and polarization data, the baryon acoustic oscillation data, the type Ia supernova JLA data, the weak lensing galaxy shear data, and the Planck 2015 lensing data. In a universe with massive sterile neutrinos, we obtain γ =0.624-0.050+0.055, with the tension with the GR prediction γ = 0.55 at the 1.48σ level, showing that the consideration of sterile neutrinos still cannot make the true measurement of γ be well consistent with the GR prediction. In a universe with massive active neutrinos, we obtain γ = 0.663 ± 0.045 for the normal hierarchy case, γ =0.661-0.050+0.044 for the degenerate hierarchy case, and γ =0.668-0.051+0.045 for the inverted hierarchy case, with the tensions with GR all at beyond the 2σ level. We find that the consideration of massive active neutrinos (no matter what mass hierarchy is considered) almost does not influence the measurement of the growth index γ.

  16. Measuring the Local Economic Impact of Universities: An Approach that Considers Uncertainty

    Science.gov (United States)

    Pastor, Jose Manuel; Perez, Francisco; de Guevara, Juan Fernandez

    2013-01-01

    The contribution of universities to society is due to the effects generated both in the supply and in the demand side, the latter being associated with the injection of demand as a result of the activities these institutions carry out. This paper focuses on the impact of the demand side by designing a methodology based on Monte Carlo simulations…

  17. Measuring efficiency of university-industry Ph.D. projects using best worst method

    NARCIS (Netherlands)

    Salimi, N.; Rezaei, J.

    2016-01-01

    A collaborative Ph.D. project, carried out by a doctoral candidate, is a type of collaboration between university and industry. Due to the importance of such projects, researchers have considered different ways to evaluate the success, with a focus on the outputs of these projects. However, what

  18. Sustainable Academia : Translating the Vision of a Fully Sustainable University into a Measurable Reality

    NARCIS (Netherlands)

    Maragakis, A.

    2017-01-01

    There is a growing public expectation that universities should start focusing on delivering sustainability. The topic of sustainability in higher education has gathered a significant amount of interest from students, academics, governments and international organizations.

    With a plethora of

  19. A Framework for Measuring Student and Staff Satisfaction with University Campus Facilities

    Science.gov (United States)

    Kärnä, Sami; Julin, Päivi

    2015-01-01

    Purpose: The purpose of the study is to evaluate and discuss the extent of the satisfaction as perceived by the students and staff towards university facilities and services in two campuses in Finland. The aim is to analyse which facility-related factors have the greatest impacts on students' and staff's overall satisfaction.…

  20. Gender diversity policies in universities: a multi-perspective framework of policy measures

    NARCIS (Netherlands)

    Timmers, T.M.; Willemsen, T.M.; Tijdens, K.G.

    2009-01-01

    Are policies to increase women’s share among university professors effective? The importance of gender equality on the labor market has been well established, but our understanding of what kind of policy is effective to increase the share of women is still unclear. Three sets of factors explain

  1. The Utilization of University Students as an Effective Measure for Reducing STIs among Teens

    Science.gov (United States)

    Spain, Adam

    2017-01-01

    Nearly 50% of all new sexually transmitted infections were found in teen and young adult populations in 2015, with the number of new infections expected to keep rising. This study evaluated the knowledge and opinions of university students to determine if changes should be made to the current sexual health education curricula utilized in high…

  2. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    The polymetallic nodules occur at an average depth of 4500 m. Adequate equipment and techniques are required for the exploration at such depths. Shipboard and various laboratory equipments for the sampling of polymetallic nodules is described...

  3. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  4. AVM branch vibration test equipment

    International Nuclear Information System (INIS)

    Anne, J.P.

    1995-01-01

    An inventory of the test equipment of the AVM Branch ''Acoustic and Vibratory Mechanics Analysis Methods'' group has been undertaken. The purpose of this inventory is to enable better acquaintance with the technical characteristics of the equipment, providing an accurate definition of their functionalities, ad to inform potential users of the possibilities and equipment available in this field. The report first summarizes the various experimental surveys conduced. Then, using the AVM equipment database to draw up an exhaustive list of available equipment, it provides a full-scope picture of the vibration measurement systems (sensors, conditioners and exciters) and data processing resources commonly used on industrial sites and in laboratories. A definition is also given of a mobile test unit, called 'shelter', and a test bench used for the testing and performance rating of the experimental analysis methods developed by the group. The report concludes with a description of two fixed installations: - the calibration bench ensuring the requisite quality level for the vibration measurement systems ; - the training bench, whereby know-how acquired in the field in the field of measurement and experimental analysis processes is made available to others. (author). 27 refs., 15 figs., 2 appends

  5. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  6. BP volume reduction equipment

    International Nuclear Information System (INIS)

    Kitamura, Yoshinori; Muroo, Yoji; Hamanaka, Isao

    2003-01-01

    A new type of burnable poison (BP) volume reduction system is currently being developed. Many BP rods, a subcomponent of spent fuel assemblies are discharged from nuclear power reactors. This new system reduces the overall volume of BP rods. The main system consists of BP rod cutting equipment, equipment for the recovery of BP cut pieces, and special transport equipment for the cut rods. The equipment is all operated by hydraulic press cylinders in water to reduce operator exposure to radioactivity. (author)

  7. Measurement of elongational viscosity of polymer melts using SER Universal Testing Platform

    Czech Academy of Sciences Publication Activity Database

    Filip, Petr; Švrčinová, Petra

    2012-01-01

    Roč. 22, č. 1 (2012), s. 14776 ISSN 1430-6395 R&D Projects: GA ČR GA103/08/1307; GA ČR GA103/09/2066 Institutional research plan: CEZ:AV0Z20600510 Keywords : elongational viscosity * SER Universal Testing Platform * polymer melts * LDPE Subject RIV: BK - Fluid Dynamics Impact factor: 1.226, year: 2012 http://www.ar.ethz.ch/TMPPDF/23074299892.48/ApplRheol_22_14776.pdf

  8. Barriers and motivators to blood donation among university students in Japan: development of a measurement tool.

    Science.gov (United States)

    Ngoma, A M; Goto, A; Yamazaki, S; Machida, M; Kanno, T; Nollet, K E; Ohto, H; Yasumura, S

    2013-10-01

    Despite growing demand for transfusion, the number of voluntary young blood donors has steadily decreased over recent years in Japan. This study aimed to develop an easy-to-use survey tool to assess barriers and motivators to blood donation among Japanese university students. We conducted cross-sectional studies at two universities in Fukushima Prefecture, Japan, in December 2011 (Stage 1) and February 2012 (Stage 2) using self-administered questionnaires. A short list of motivators and barriers to blood donation was developed from the open-ended questions asked of 50 students in Stage 1. In the Stage 2, we asked 105 students how important these items were when they decided whether or not to donate blood. Items showing a significant difference between donors and non-donors were kept in the final list. Overall, 56% of the 100 participants analysed in Stage 2 were men, and ages ranged from 19 to 24 with a median of 20 years. Comparison of motivators and barriers between donors and non-donors revealed that only barrier item 8 ('Frightened by blood donation') showed a significant difference (P = 0·0006) in an expected direction and with a consistency between two universities. This study identified fear as being the most significant barrier to blood donation among Japanese university students, which could be used as a single convenient indicator to assess their readiness to donate. More academic and clinical efforts are needed to understand and address students' fear towards blood donation in order to increase the donor pool in Japan. © 2013 International Society of Blood Transfusion.

  9. Image quality control of mammography equipment -Mammography System MX-300- of the Teachers Hospital of UNSA and dose measurement in breasts with radiographic films

    International Nuclear Information System (INIS)

    Quispe F, L. K.; Vega R, J.

    2015-10-01

    This work is part of medical imaging for the evaluation of quality. Will have an accredited breast phantom Rmi-156 that allows evaluating the image quality of mammography equipment and through a series of techniques and processes that will submit to mammography films we obtain characteristic curves, which allows to evaluate different parameters that will serve for our study. Images were acquired with different k Vp and m As of the equipment, also with different thicknesses of the breast phantom. Also we want to use the lowest possible dose for obtaining our images. In this paper we develop a simple protocol that aims to unify the conditions under which are acquired the images for later evaluation. By obtaining these characteristic curves demonstrate that the Kodak film is the most suitable for our study because it requires lower dose for obtaining our images. (Author)

  10. Observations on the electronic equipment employed for making measurements on the pile G1; Observations sur le materiel electronique utilise pour les mesures sur la pile G1

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J; Belin, P; Meunier, A; Tarabella, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The electronic apparatus employed during the manipulations carried out on the pile G1 is briefly described, with the aim of putting on record the inconveniences encountered in the course of the operation of this equipment. (author) [French] On decrit succinctement l'appareillage electronique utilise durant les manipulations effectuees sur la pile G1, dans le but de noter les inconvenients rencontres au cours de l'exploitation de cet appareillage. (auteur)

  11. Screening and contact precautions – A survey on infection control measures for multidrug-resistant bacteria in German university hospitals

    Directory of Open Access Journals (Sweden)

    Lena M. Biehl

    2017-04-01

    Full Text Available Abstract To assess the scope of infection control measures for multidrug-resistant bacteria in high-risk settings, a survey among university hospitals was conducted. Fourteen professionals from 8 sites participated. Reported policies varied largely with respect to the types of wards conducting screening, sample types used for screening and implementation of contact precautions. This variability among sites highlights the need for an evidence-based consensus of current infection control policies.

  12. Verification of the thermal design of electronic equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hienonen, R.; Karjalainen, M.; Lankinen, R. [VTT Automation, Espoo (Finland). ProTechno

    1997-12-31

    The project `Verification of the thermal design of electronic equipment` studied the methodology to be followed in the verification of thermal design of electronic equipment. This project forms part of the `Cool Electronics` research programme funded by TEKES, the Finnish Technology Development Centre. This project was carried out jointly by VTT Automation, Lappeenranta University of Technology, Nokia Research Center and ABB Industry Oy VSD-Technology. The thermal design of electronic equipment has a significant impact on the cost, reliability, tolerance to different environments, selection of components and materials, and ergonomics of the product. This report describes the method for verification of thermal design. It assesses the goals set for thermal design, environmental requirements, technical implementation of the design, thermal simulation and modelling, and design qualification testing and the measurements needed. The verification method covers all packaging levels of electronic equipment from the system level to the electronic component level. The method described in this report can be used as part of the quality system of a corporation. The report includes information about the measurement and test methods needed in the verification process. Some measurement methods for the temperature, flow and pressure of air are described. (orig.) Published in Finnish VTT Julkaisuja 824. 22 refs.

  13. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  14. An on-line monitoring system for navigation equipment

    Science.gov (United States)

    Wang, Bo; Yang, Ping; Liu, Jing; Yang, Zhengbo; Liang, Fei

    2017-10-01

    Civil air navigation equipment is the most important infrastructure of Civil Aviation, which is closely related to flight safety. In addition to regular flight inspection, navigation equipment's patrol measuring, maintenance measuring, running measuring under special weather conditions are the important means of ensuring aviation flight safety. According to the safety maintenance requirements of Civil Aviation Air Traffic Control navigation equipment, this paper developed one on-line monitoring system with independent intellectual property rights for navigation equipment, the system breakthroughs the key technologies of measuring navigation equipment on-line including Instrument Landing System (ILS) and VHF Omni-directional Range (VOR), which also meets the requirements of navigation equipment ground measurement set by the ICAO DOC 8071, it provides technical means of the ground on-line measurement for navigation equipment, improves the safety of navigation equipment operation, and reduces the impact of measuring navigation equipment on airport operation.

  15. Measuring human betterment through avoidable mortality: a case for universal health care in the USA.

    Science.gov (United States)

    Hisnanick, J J; Coddington, D A

    1995-10-01

    The USA system of health care has begun a monumental change that will affect everyone, irrespective of their socioeconomic status, professional status or pre-existing health insurance status. Whatever type of plan is finally implemented through the legislative process, there will need to be a way to evaluate its success (or failure). One way to evaluate the plan's effectiveness is through its impact on human betterment as viewed by a reduction in 'avoidable mortality' for those most in need of health care; the poor and uninsured. For one USA minority population, universal health care has improved human betterment by reducing avoidable mortality, even in the face of a severe burden of poverty.

  16. Taking the Measure of the Universe: Cosmology from the WMAP Mission

    Science.gov (United States)

    Hinshaw, Gary F.

    2007-01-01

    The data from the first three years of operation of the Wilkinson Microwave Anisotropy Probe (WMAP) satellite provide detailed full-sky maps of the cosmic microwave background temperature anisotropy and new full-sky maps of the polarization. Together, the data provide a wealth of cosmological information, including the age of the universe, the epoch when the first stars formed, and the overall composition of baryonic matter, dark matter, and dark energy. The results also provide constraints on the period of inflationary expansion in the very first moments of time. These and other aspects of the mission will be discussed.

  17. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  18. Socket for a central connection for measuring equipment into a transistor ignition system of an internal combustion engine. Steckdose einer Zentralsteckverbindung fuer den Anschluss von Messgeraeten an eine Transistorzuendung einer Brennkraftmaschine

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, H

    1980-09-25

    The invention refers to the socket of a central connection for measuring equipment into a transistor ignition system of an internal combustion engine. Various cables are looped into the transistor ignition system via the pins of this socket. By plugging in a multi-pole plug, the individual circuits of the ignition system are made. In this way, apart from connecting the measuring equipment for testing the transistor ignition system, it is possible to prevent the ignition system working in case of theft of the vehicle, by inserting a 'blind plate' which leaves individual circuits of the transistor system open. Structural details of this cylindrical socket and the multiple plug are explained in some crossection diagrams. The ideas of the invention are described in 7 patent claims.

  19. Measurement equipment fitted in light vehicles used for supervision and reconnaissance by the radioprotection service at Cadarache; Equipement de mesures des vehicules legers de surveillance et de reconnaissance de la S. P. R. Cadarache

    Energy Technology Data Exchange (ETDEWEB)

    Galanti, A; Thirion, C; Grandin, M [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1967-07-01

    Normally, these vehicles are used to reinforce the atmospheric supervision network based on four fixed stations. In the case of a planned atmospheric discharge they have to control contamination levels and check that these conform to the scattering forecasts. In the case of accidental atmospheric pollution, their role is to rapidly demarcate the pollution zones and to follow the evolution of this pollution. The main measurements carried out are: - Detection of ambient gamma radiation from 10 {mu}rad/hr to 1000 rad/hr. - Detection of the alpha and gamma contamination. - Detection of the beta and gamma contamination of the ground. (authors) [French] En temps normal, ces vehicules ont pour but de completer le reseau de surveillance atmospherique qui s'appuie sur quatre stations fixes. En cas de rejet atmospherique concerte, ils doivent controler les niveaux de contamination et verifier qu'ils sont conformes aux previsions de diffusion. En cas de rejet atmospherique accidentel, ils ont pour mission de delimiter rapidement les zones de pollution et tenir a jour leur evolution. Les principales mesures effectuees sont: - Detection des gamma ambiants de lO {mu}rad/h a 1000 rad/h. - Detection de la contamination atmospherique en alpha et beta. - Detection de la contamination du sol en beta et gamma. (auteurs)

  20. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  1. Measuring Responsibility and Cooperation in Learning Teams in the University Setting: Validation of a Questionnaire

    Science.gov (United States)

    León-del-Barco, Benito; Mendo-Lázaro, Santiago; Felipe-Castaño, Elena; Fajardo-Bullón, Fernando; Iglesias-Gallego, Damián

    2018-01-01

    Cooperative learning are being used increasingly in the university classroom, in order to promote teamwork among students, improve performance and develop interpersonal competences. Responsibility and cooperation are two fundamental pillars of cooperative learning. Team members’ responsibility is a necessary condition for the team’s success in the assigned tasks. Students must be aware that they depend on each other and should make their maximum effort. On the other hand, in efficient groups, the members cooperate and pool their efforts to achieve the proposed goals. In this research, we propose to create a Questionnaire of Group Responsibility and Cooperation in Learning Teams (CRCG). Participants in this work were 375 students from the Faculty of Teacher Training of the University of Extremadura (Spain). The CRCG has very acceptable psychometric characteristics, good internal consistency, and temporal reliability. Moreover, structural equation analysis allowed us to verify that the latent variables in the two factors found are well defined and, therefore, their assessment is adequate. Besides, we found high significant correlations between the Learning Team Potency Questionnaire (CPEA) and the total score and the factors of the CRCG. This tool will evaluate cooperative skills and offer faculty information in order to prepare students for teamwork and conflict resolution. PMID:29593622

  2. An intercept study to measure the extent to which New Zealand university students pre-game.

    Science.gov (United States)

    Riordan, Benjamin C; Conner, Tamlin S; Flett, Jayde A M; Droste, Nic; Cody, Louise; Brookie, Kate L; Riordan, Jessica K; Scarf, Damian

    2018-02-01

    We aimed to quantify the degree to which students pre-gamed in New Zealand, using self-report and breathalysers. A total of 569 New Zealand undergraduate students were interviewed (men = 45.2%; first year = 81.4%) entering three university-run concerts. We asked participants to report how many drinks they had consumed, their self-reported intoxication and the duration of their pre-gaming session. We then recorded participants' Breath Alcohol Concentration (BrAC; µg/L) and the time they arrived at the event. The number of participants who reported consuming alcohol before the event was 504 (88.6%) and the number of standard drinks consumed was high (M=6.9; median=6.0). A total of 237 (41.7%) participants could not have their BrAC recorded due to having consumed alcohol ≤10 minutes before the interview. The remaining 332 participants (57.3%) recorded a mean BrAC of 288.8µg/L (median=280.0 µg/L). Gender, off-campus accommodation, length of pre-gaming drinking session, and time of arrival at the event were all associated with increased pre-gaming. Conclusion and implications for public health: Pre-gaming was the norm for students. Universities must take pre-gaming into account; policy implications include earlier start times of events and limiting students' access to alcohol prior to events. © 2017 The Authors.

  3. Temperament in Portuguese university students as measured by TEMPS-A: implications for professional choice.

    Science.gov (United States)

    Figueira, M Luisa; Caeiro, Lara; Ferro, Ana; Cordeiro, Raul; Duarte, Pedro M; Akiskal, Hagop S; Akiskal, Kareen K

    2010-06-01

    The structure of temperament displays subaffective traits as attributes of adaptive value. There are few studies on how different professions compare on temperaments. Our aim was to examine the relationship between the choices of Portuguese students in their fields of study, and their respective temperaments. The sample included 1386 students from six different universities (law, engineering, arts, medicine, psychology, and nursing), of both genders (67% female), and ages between 17 and 58 (X + or - SD = 21 + or - 3.4). Law and art students presented a cyclothymic or irritable temperament. Engineering students presented a hyperthymic temperament. Psychology and nursing students presented predominantly depressive and anxious temperaments. Medicine students were least extreme in temperament scores or frequencies. Nursing students came largely from one university located in a Portuguese city (northeast from Lisbon) which could be a potential limitation to be confirmed. Distinct temperamental profiles of students enrolled in different professional fields could be identified in our sample taking into account the presence or absence of excessive temperaments. Future physicians did not present a predominant temperament, future lawyers and artists presented predominantly a cyclothymic or irritable temperament, future engineers presented a hyperthymic temperament and, future psychologists and nurses presented predominantly depressive and anxious temperaments. Copyright 2009 Elsevier B.V. All rights reserved.

  4. Measuring Responsibility and Cooperation in Learning Teams in the University Setting: Validation of a Questionnaire

    Directory of Open Access Journals (Sweden)

    Benito León-del-Barco

    2018-03-01

    Full Text Available Cooperative learning are being used increasingly in the university classroom, in order to promote teamwork among students, improve performance and develop interpersonal competences. Responsibility and cooperation are two fundamental pillars of cooperative learning. Team members’ responsibility is a necessary condition for the team’s success in the assigned tasks. Students must be aware that they depend on each other and should make their maximum effort. On the other hand, in efficient groups, the members cooperate and pool their efforts to achieve the proposed goals. In this research, we propose to create a Questionnaire of Group Responsibility and Cooperation in Learning Teams (CRCG. Participants in this work were 375 students from the Faculty of Teacher Training of the University of Extremadura (Spain. The CRCG has very acceptable psychometric characteristics, good internal consistency, and temporal reliability. Moreover, structural equation analysis allowed us to verify that the latent variables in the two factors found are well defined and, therefore, their assessment is adequate. Besides, we found high significant correlations between the Learning Team Potency Questionnaire (CPEA and the total score and the factors of the CRCG. This tool will evaluate cooperative skills and offer faculty information in order to prepare students for teamwork and conflict resolution.

  5. Measuring Responsibility and Cooperation in Learning Teams in the University Setting: Validation of a Questionnaire.

    Science.gov (United States)

    León-Del-Barco, Benito; Mendo-Lázaro, Santiago; Felipe-Castaño, Elena; Fajardo-Bullón, Fernando; Iglesias-Gallego, Damián

    2018-01-01

    Cooperative learning are being used increasingly in the university classroom, in order to promote teamwork among students, improve performance and develop interpersonal competences. Responsibility and cooperation are two fundamental pillars of cooperative learning. Team members' responsibility is a necessary condition for the team's success in the assigned tasks. Students must be aware that they depend on each other and should make their maximum effort. On the other hand, in efficient groups, the members cooperate and pool their efforts to achieve the proposed goals. In this research, we propose to create a Questionnaire of Group Responsibility and Cooperation in Learning Teams (CRCG) . Participants in this work were 375 students from the Faculty of Teacher Training of the University of Extremadura (Spain). The CRCG has very acceptable psychometric characteristics, good internal consistency, and temporal reliability. Moreover, structural equation analysis allowed us to verify that the latent variables in the two factors found are well defined and, therefore, their assessment is adequate. Besides, we found high significant correlations between the Learning Team Potency Questionnaire (CPEA) and the total score and the factors of the CRCG. This tool will evaluate cooperative skills and offer faculty information in order to prepare students for teamwork and conflict resolution.

  6. Measuring relative efficiency of applied science and technology universities in province of Semnan, Iran and providing suggestions for merging units

    Directory of Open Access Journals (Sweden)

    Abolfazl Danaei

    2013-03-01

    Full Text Available University of applied science and technology has been designed to create a platform for multilateral activities such as industrial, military and academic in developing countries to promote science and scientific research applications. These universities are responsible to promote practical training in quantitative and qualitative indicators and they provide appropriate infrastructure to implement theoretical graduates to solve practical problems to build necessary infrastructure to transfer modern technology into developing countries. During the past few years, there have been tremendous development on these units but some of them have not been efficient. In this paper, we present an empirical study to measure the relative efficiencies of various units of applied science and technology universities using data envelopment analysis. The proposed model of this paper uses two inputs including human resources as well as total assets and two outputs including the number of graduate students as well as operating profit. The results of the study have indicated that some of the units are inefficient and need to be merged with other units to increase the relative efficiency of these universities.

  7. Developing the University of the Philippines Loneliness Assessment Scale: A Cross-Cultural Measurement

    Science.gov (United States)

    Tharayil, Davis Porinchu

    2012-01-01

    As the existing scales to measure loneliness are almost all Western and there is no single scale developed cross-culturally for this purpose, this study is designed to develop a reliable and valid scale to measure the experience of loneliness of individuals from individualistic or collectivistic cultures. There are three samples for this study…

  8. Measurements of airborne short-lived radioactivity concentration in a PET facility at a national University hospital

    International Nuclear Information System (INIS)

    Saito, Tadashi

    2006-01-01

    National universities in Japan became under regulation of Industrial Safety and Health Law since 2004FY. One of the legal obligations is working environment measurements such as airborne radioactivity concentration in the rooms where employees handle unsealed radiation sources. Both in 2004FY and in 2005FY, measurements of airborne radioactivity concentration were carried out by two different agencies. The most prominent difference among them is the measurement for short-lived PET nuclides. In 2004FY, one agency measured the radioactivity with a Ge spectrometer at its own laboratory, whereas, in 2005FY, the other agency brought a NaI scintillation counter for gross gamma counting to the Hospital. It can be shown that detection limits for short-lived PET nuclides are in principle almost the same in both methods. It is also found that, in the actual case, gamma spectrometry with a Ge spectrometer is superior in judgement of detection of the radioactivity. (author)

  9. Signatures of the Primordial Universe from Its Emptiness: Measurement of Baryon Acoustic Oscillations from Minima of the Density Field.

    Science.gov (United States)

    Kitaura, Francisco-Shu; Chuang, Chia-Hsun; Liang, Yu; Zhao, Cheng; Tao, Charling; Rodríguez-Torres, Sergio; Eisenstein, Daniel J; Gil-Marín, Héctor; Kneib, Jean-Paul; McBride, Cameron; Percival, Will J; Ross, Ashley J; Sánchez, Ariel G; Tinker, Jeremy; Tojeiro, Rita; Vargas-Magana, Mariana; Zhao, Gong-Bo

    2016-04-29

    Sound waves from the primordial fluctuations of the Universe imprinted in the large-scale structure, called baryon acoustic oscillations (BAOs), can be used as standard rulers to measure the scale of the Universe. These oscillations have already been detected in the distribution of galaxies. Here we propose to measure BAOs from the troughs (minima) of the density field. Based on two sets of accurate mock halo catalogues with and without BAOs in the seed initial conditions, we demonstrate that the BAO signal cannot be obtained from the clustering of classical disjoint voids, but it is clearly detected from overlapping voids. The latter represent an estimate of all troughs of the density field. We compute them from the empty circumsphere centers constrained by tetrahedra of galaxies using Delaunay triangulation. Our theoretical models based on an unprecedented large set of detailed simulated void catalogues are remarkably well confirmed by observational data. We use the largest recently publicly available sample of luminous red galaxies from SDSS-III BOSS DR11 to unveil for the first time a >3σ BAO detection from voids in observations. Since voids are nearly isotropically expanding regions, their centers represent the most quiet places in the Universe, keeping in mind the cosmos origin and providing a new promising window in the analysis of the cosmological large-scale structure from galaxy surveys.

  10. Use of performance metrics for the measurement of universal coverage for maternal care in Mexico.

    Science.gov (United States)

    Serván-Mori, Edson; Contreras-Loya, David; Gomez-Dantés, Octavio; Nigenda, Gustavo; Sosa-Rubí, Sandra G; Lozano, Rafael

    2017-06-01

    This study provides evidence for those working in the maternal health metrics and health system performance fields, as well as those interested in achieving universal and effective health care coverage. Based on the perspective of continuity of health care and applying quasi-experimental methods to analyse the cross-sectional 2009 National Demographic Dynamics Survey (n = 14 414 women), we estimated the middle-term effects of Mexico's new public health insurance scheme, Seguro Popular de Salud (SPS) (vs women without health insurance) on seven indicators related to maternal health care (according to official guidelines): (a) access to skilled antenatal care (ANC); (b) timely ANC; (c) frequent ANC; (d) adequate content of ANC; (e) institutional delivery; (f) postnatal consultation and (g) access to standardized comprehensive antenatal and postnatal care (or the intersection of the seven process indicators). Our results show that 94% of all pregnancies were attended by trained health personnel. However, comprehensive access to ANC declines steeply in both groups as we move along the maternal healthcare continuum. The percentage of institutional deliveries providing timely, frequent and adequate content of ANC reached 70% among SPS women (vs 64.7% in the uninsured), and only 57.4% of SPS-affiliated women received standardized comprehensive care (vs 53.7% in the uninsured group). In Mexico, access to comprehensive antenatal and postnatal care as defined by Mexican guidelines (in accordance to WHO recommendations) is far from optimal. Even though a positive influence of SPS on maternal care was documented, important challenges still remain. Our results identified key bottlenecks of the maternal healthcare continuum that should be addressed by policy makers through a combination of supply side interventions and interventions directed to social determinants of access to health care. © The Author 2017. Published by Oxford University Press in association with The

  11. Radioactivity measurement of the liquid effluents of two university hospital methodology, problems arising

    International Nuclear Information System (INIS)

    Basse-Cathalinat, B.; Barthe, N.; Chatti, K.; Ducassou, D.

    2005-01-01

    The authors present methodology used to measure the radioactivity of the effluents at the output of two services of Nuclear medicine located in two Hospital complexes of the Area of Bordeaux. These measures are intended to answer at the requests of circular DGS/DHOS no 2001/323 of the Ministry for Employment and Solidarity. The selected method is more powerful since it is based on the use of a whole of spectrometry to very low background noise. These devices of measurements make it possible to take into account all the isotopes coming from a service of Nuclear medicine. The authors are conscious that of such measurements cannot be considered in all the services of Nuclear medicine. Other technical articles will specify simpler methods allowing a satisfactory management of the radioactive wastes. (author)

  12. Jagiellonian University Selected Results on the CKM Angle $\\gamma $ Measurement at the LHCb

    CERN Document Server

    Krupa, Wojciech

    2017-01-01

    The LHCb is a single arm forward spectrometer designed to study heavy-flavour physics at the LHC. Its very precise tracking and excellent particle identification play currently a major role in providing the world-best measurements of the Unitary Triangle parameters. In this paper, selected results of the Cabibbo–Kobayashi–Maskawa (CKM) angle $\\gamma$ measurements, with special attention for $B \\rightarrow DK$ decays family, obtained at the LHCb, are presented.

  13. Data envelopment analysis with upper bound on output to measure efficiency performance of departments in Malaikulsaleh University

    Science.gov (United States)

    Abdullah, Dahlan; Suwilo, Saib; Tulus; Mawengkang, Herman; Efendi, Syahril

    2017-09-01

    The higher education system in Indonesia can be considered not only as an important source of developing knowledge in the country, but also could create positive living conditions for the country. Therefore it is not surprising that enrollments in higher education continue to expand. However, the implication of this situation, the Indonesian government is necessarily to support more funds. In the interest of accountability, it is essential to measure the efficiency for this higher institution. Data envelopment analysis (DEA) is a method to evaluate the technical efficiency of production units which have multiple input and output. The higher learning institution considered in this paper is Malikussaleh University located in Lhokseumawe, a city in Aceh province of Indonesia. This paper develops a method to evaluate efficiency for all departments in Malikussaleh University using DEA with bounded output. Accordingly, we present some important differences in efficiency of those departments. Finally we discuss the effort should be done by these departments in order to become efficient.

  14. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  15. Measuring Student Improvement in Lower- and Upper-Level University Climate Science Courses

    Science.gov (United States)

    Harris, S. E.; Taylor, S. V.; Schoonmaker, J. E.; Lane, E.; Francois, R. H.; Austin, P.

    2011-12-01

    What do university students know about climate? What do they learn in a climate course? On the second-to-last day of a course about global climate change, only 48% of our upper-level science students correctly answered a multiple-choice question about the greenhouse effect. The good news: improvement. Only 16% had answered correctly on the first day of class. The bad news: the learning opportunities we've provided appear to have missed more than half the class on a fundamental climate concept. To evaluate the effectiveness of instruction on student learning about climate, we have developed a prototype assessment tool, designed to be deployed as a low-stakes pre-post test. The items included were validated through student interviews to ensure that students interpret the wording and answer choices in the way we intend. This type of validated assessment, administered both at the beginning and end of term, with matched individuals, provides insight regarding the baseline knowledge with which our students enter a course, and the impact of that course on their learning. We administered test items to students in (1) an upper-level climate course for science majors and (2) a lower-level climate course open to all students. Some items were given to both groups, others to only one of the groups. Both courses use evidence-based pedagogy with active student engagement (clickers, small group activities, regular pre-class preparation). Our results with upper-level students show strong gains in student thinking (>70% of students who missed a question on the pre-test answered correctly on the post-test) about stock-and-flow (box model) problems, annual cycles in the Keeling curve, ice-albedo feedbacks, and isotopic fractionation. On different questions, lower-level students showed strong gains regarding albedo and blackbody emission spectra. Both groups show similar baseline knowledge and lower-than-expected gains on greenhouse effect fundamentals, and zero gain regarding the

  16. Field measurements of perceived air quality and concentration of volatile organic compounds in four offices of the university building

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Toftum, Jørn; Kabrhel, M.

    2015-01-01

    Field measurements of perceived air quality were conducted in four refurbished offices at the Czech Technical University in Prague. The offices were refurbished as part of the research project Clear-up to serve as a field test facility. The present paper describes measurements conducted...... according to CEN Report CR 1752. The acceptability of the air quality was worst in unoccupied offices ventilated with minimum air change rate (0.4 h-1). Application of DCV decreased the CO2 concentration, but did not result in statistically significant improvement of perceived air quality....... to investigate the perceived air quality, sensory pollution load and concentration of Volatile Organic Compounds (VOCs) in the offices. As the refurbishment comprised also installation of demand controlled ventilation (DCV), its influence on the perceived air quality was also tested. Measurements comprised...

  17. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  18. Waste incineration models for operation optimization. Phase 1: Advanced measurement equipment for improved operation of waste fired plants; Affaldsforbraendingsmodeller til driftsoptimering. Fase 1: Avanceret maeleudstyr til forbedret drift af affaldsfyrede anlaeg

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-06-01

    This report describes results from the PSO projects ELTRA-5294 and ELTRA-5348: Waste incineration models for operation optimization. Phase 1, and Advanced measurement equipment for improved operation of waste fired plants. Phase 1. The two projects form the first step in a project course build on a long-term vision of a fully automatic system using a wide range of advanced measurement data, advanced dynamic models for prediction of operation and advanced regulation methods for optimization of the operation of waste incinerator plants. (BA)

  19. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  20. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  1. 24 CFR 965.306 - Energy conservation equipment and practices.

    Science.gov (United States)

    2010-04-01

    ... Measures § 965.306 Energy conservation equipment and practices. In purchasing original or, when needed, replacement equipment, PHAs shall acquire only equipment that meets or exceeds the minimum efficiency... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Energy conservation equipment and...

  2. Smartphone and Universal Goniometer for Measurement of Elbow Joint Motions: A Comparative Study

    Science.gov (United States)

    Behnoush, Behnam; Tavakoli, Nasim; Bazmi, Elham; Nateghi Fard, Fariborz; Pourgharib Shahi, Mohammad Hossein; Okazi, Arash; Mokhtari, Tahmineh

    2016-01-01

    Background Universal goniometer (UG) is commonly used as a standard method to evaluate range of motion (ROM) as part of joint motions. It has some restrictions, such as involvement of both hands of the physician, leads to instability of hands and error. Nowadays smartphones usage has been increasing due to its easy application. Objectives The study was designed to compare the smartphone inclinometer-based app and UG in evaluation of ROM of elbow. Materials and Methods The maximum ROM of elbow in position of flexion and pronation and supination of forearm were examined in 60 healthy volunteers with UG and smartphone. Data were analyzed using SPSS (ver. 16) software and appropriate statistical tests were applied, such as paired t-test, ICC and Bland Altman curves. Results The results of this study showed high reliability and validity of smartphone in regarding UG with ICC > 0.95. The highest reliability for both methods was in elbow supination and the lowest was in the elbow flexion (0.84). Conclusions Smartphones due to ease of access and usage for the physician and the patient, may be good alternatives for UG. PMID:27625754

  3. Development and Validation of an Instrument to Measure University Students' Biotechnology Attitude

    Science.gov (United States)

    Erdogan, Mehmet; Ozel, Murat; Usak, Muhammet; Prokop, Pavol

    2009-01-01

    The impact of biotechnologies on peoples' everyday lives continuously increases. Measuring young peoples' attitudes toward biotechnologies is therefore very important and its results are useful not only for science curriculum developers and policy makers, but also for producers and distributors of genetically modified products. Despite of…

  4. Lost Souls? The Demoralization of Academic Labour in the Measured University

    Science.gov (United States)

    Sutton, Paul

    2017-01-01

    In this conceptual paper, I contend that the soul of academic labour is becoming lost in performativity. Performativity, I explain, is a form of regulation and control that deploys technical rationality and judgements to incentivize and punish academics. Indeed, performativity is central to the culture of measurement within contemporary…

  5. Proposal for a universal measurement system for school chairs and desks for children from 6 to 10 years old.

    Science.gov (United States)

    Carneiro, Vitor; Gomes, Ângela; Rangel, Bárbara

    2017-01-01

    In a primary education classroom of any country, children of the same age have very different statures, reaching variations of 200 mm (Gonçalves, 2012). However, the school furniture provided is not suitable or adaptable to these differences. Designing school furniture able to respond to these variations is, therefore, a challenge for ergonomics and design in a global market. It is clearly not viable for industries to adapt productions for each country. When competitiveness and limitation of resources are essential for the viability of any product it becomes essential to find a universal system adapted to the requisites of any country. Taking as prescription measure the popliteal height obtained from the data of different countries, a universal measurement system for the school chair and desk set is proposed, combining the ellipse methodology used by Molenbroek et al. (2003) and the (mis)match equations mentioned by Castellucci et al. (2014b). From the results obtained, it can be concluded that only 5 sizes are needed to implement this new measurement system of evolutionary school furniture for the primary education classroom. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Universal Quantum Computing with Measurement-Induced Continuous-Variable Gate Sequence in a Loop-Based Architecture.

    Science.gov (United States)

    Takeda, Shuntaro; Furusawa, Akira

    2017-09-22

    We propose a scalable scheme for optical quantum computing using measurement-induced continuous-variable quantum gates in a loop-based architecture. Here, time-bin-encoded quantum information in a single spatial mode is deterministically processed in a nested loop by an electrically programmable gate sequence. This architecture can process any input state and an arbitrary number of modes with almost minimum resources, and offers a universal gate set for both qubits and continuous variables. Furthermore, quantum computing can be performed fault tolerantly by a known scheme for encoding a qubit in an infinite-dimensional Hilbert space of a single light mode.

  7. Validation study of the Forgotten Joint Score-12 as a universal patient-reported outcome measure.

    Science.gov (United States)

    Matsumoto, Mikio; Baba, Tomonori; Homma, Yasuhiro; Kobayashi, Hideo; Ochi, Hironori; Yuasa, Takahito; Behrend, Henrik; Kaneko, Kazuo

    2015-10-01

    The Forgotten Joint Score-12 (FJS-12) is for patients to forget their artificial joint and is reportedly a useful patient-reported outcome tool for artificial joints. The purpose of this study was to determine whether the FJS-12 is as useful as the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) or the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) in Japan. All patients who visited our hospital's hip joint specialists following unilateral THA from August 2013 to July 2014 were evaluated. Medical staff members other than physicians administered three questionnaires. Items evaluated were (1) the reliability of the FJS-12 and (2) correlations between the FJS-12 and the total and subscale scores of the WOMAC or JHEQ. Of 130 patients, 22 were excluded. Cronbach's α coefficient was 0.97 for the FJS-12. The FJS-12 showed a significantly lower score than the WOMAC or JHEQ (p < 0.01). The FJS-12 was moderately correlated with the total WOMAC score (r = 0.522) and its subscale scores for "stiffness" (r = 0.401) and "function" (r = 0.539) and was weakly correlated with the score for "pain" (r = 0.289). The FJS-12 was favorably correlated with the total JHEQ score (r = 0.686) and its subscale scores (r = 0.530-0.643). The FJS-12 was correlated with and showed reliability similar to that of the JHEQ and WOMAC. The FJS-12, which is not affected by culture or lifestyle, may be useful in Japan.

  8. Dual-Pump CARS Measurements in the University of Virginia's Dual-Mode Scramjet: Configuration "A"

    Science.gov (United States)

    Cutler, Andrew D.; Magnotti, Gaetano; Gallo, Emanuela; Danehy, Paul M.; Rockwell, Robert; Goyne, Christopher P.; McDaniel, James

    2012-01-01

    In this paper we describe efforts to obtain canonical data sets to assist computational modelers in their development of models for the prediction of mixing and combustion in scramjet combustors operating in the ramjet-scramjet transition regime. The CARS technique is employed to acquire temporally and spatially resolved measurements of temperature and species mole-fraction at four planes, one upstream of an H2 fuel injector and three downstream. The technique is described and results are presented for cases with and without chemical reaction. The vibrational energy mode in the heated airstream of the combustor was observed to be frozen at near facility heater conditions and significant nonuniformities in temperature were observed, attributed to nonuniformities of temperature exiting the heater. The measurements downstream of fuel injection show development of mixing and combustion, and are already proving useful to the modelers.

  9. Measurment of Web Usability: Web Page of Hacettepe University Department of Information Management

    OpenAIRE

    Nazan Özenç Uçak; Tolga Çakmak

    2009-01-01

    Today, information is produced increasingly in electronic form and retrieval of information is provided via web pages. As a result of the rise of the number of web pages, many of them seem to comprise similar contents but different designs. In this respect, presenting information over the web pages according to user expectations and specifications is important in terms of effective usage of information. This study provides an insight about web usability studies that are executed for measuring...

  10. Taking the Measure of the Universe: Precision Astrometry with SIM Planetquest (Preprint)

    Science.gov (United States)

    2006-10-09

    streams, and § 11 explains how astro- metric microlensing provides insight into the mass spec- trum of dark bodies in the Galaxy. § 12 and 13 cover...condensates, and quark matter) can reproduce this mass for a large range of radii (Lattimer & Prakash 2004). However, more recently, there are indications...diameter, repre- sented by the dark circle in the center, was measured with the VLTI while the circumstellar SiO masers were imaged concurrently with

  11. The Motion Path Study of Measuring Robot Based on Variable Universe Fuzzy Control

    Directory of Open Access Journals (Sweden)

    Ma Guoqing

    2017-01-01

    Full Text Available For the problem of measuring robot requires a higher positioning, firstly learning about the error overview of the system, analysised the influence of attitude, speed and other factors on systematic errors. Then collected and analyzed the systematic error curve in the track to complete the planning process. The last adding fuzzy control in both cases, by comparing with the original system, can found that the method based on fuzzy control system can significantly reduce the error during the motion.

  12. Pulsed and monoenergetic beams for neutron cross-section measurements using activation and scattering techniques at Triangle Universities Nuclear Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hutcheson, A. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States)]. E-mail: hutch@tunl.duke.edu; Angell, C.T. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Becker, J.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Boswell, M. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Crowell, A.S. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Dashdorj, D. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Fallin, B. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Fotiades, N. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Howell, C.R.; Karwowski, H.J.; Kelley, J.H.; Kiser, M. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Macri, R.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Nelson, R.O. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Pedroni, R.S. [NC A and T State University, 1601 East Market Street, Greensboro, NC 27411 (United States); Tonchev, A.P.; Tornow, W. [Triangle Universities Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 (United States); Vieira, D.J. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States); Weisel, G.J. [Penn State Altoona, 3000 Ivyside Park, Altoona, PA 16601 (United States); Wilhelmy, J.B. [Los Alamos National Laboratory, P.O. Box 1663, Los Alamos, NM 87545 (United States)

    2007-08-15

    In support of the Stewardship Science Academic Alliances initiative, an experimental program has been developed at Triangle Universities Nuclear Laboratory (TUNL) to measure (n,xn) cross-sections with both in-beam and activation techniques with the goal of improving the partial cross-section database for the NNSA Stockpile Stewardship Program. First experimental efforts include excitation function measurements on {sup 235,238}U and {sup 241}Am using pulsed and monoenergetic neutron beams with E {sub n} = 5-15 MeV. Neutron-induced partial cross-sections were measured by detecting prompt {gamma} rays from the residual nuclei using various combinations of clover and planar HPGe detectors in the TUNL shielded neutron source area. Complimentary activation measurements using DC neutron beams have also been performed in open geometry in our second target area. The neutron-induced activities were measured in the TUNL low-background counting area. In this presentation, we include detailed information about the irradiation procedures and facilities and preliminary data on first measurements using this capability.

  13. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  14. Capital Equipment Replacement Decisions

    OpenAIRE

    Batterham, Robert L.; Fraser, K.I.

    1995-01-01

    This paper reviews the literature on the optimal replacement of capital equipment, especially farm machinery. It also considers the influence of taxation and capital rationing on replacement decisions. It concludes that special taxation provisions such as accelerated depreciation and investment allowances are unlikely to greatly influence farmers' capital equipment replacement decisions in Australia.

  15. Educational "Goodwill": Measuring the Intangible Assets at Highly Selective Private Colleges and Universities

    OpenAIRE

    Peter Nurnberg; Morton Schapiro; David Zimmerman

    2011-01-01

    In this paper we utilize data on the head-to-head loss rate for students accepted at Williams College, but who opt to enroll elsewhere. For example, we employ data that measure the fraction of students admitted to Williams and to Amherst (or Harvard or Yale, etc.) but who opt to attend Amherst (or Harvard or Yale, etc.) instead of Williams. We then model this head-to-head loss rate using data from a variety of sources. A better understanding of the head-to-head loss rate can assist an institu...

  16. Measuring spirituality as a universal human experience: development of the Spiritual Attitude and Involvement List (SAIL).

    Science.gov (United States)

    de Jager Meezenbroek, Eltica; Garssen, Bert; Van den Berg, Machteld; Tuytel, Gerwi; Van Dierendonck, Dirk; Visser, Adriaan; Schaufeli, Wilmar B

    2012-01-01

    Many cancer patients experience spirituality as highly supportive while coping with their disease. Most research as well as most questionnaires in this field is religious orientated. The Spiritual Attitude and Involvement List was developed to enable research on spirituality among religious and nonreligious people. It consists of seven subscales that measure connectedness with oneself, with others and nature, and with the transcendent. Among a student, a healthy population, a healthy interested, a curative cancer, and a palliative cancer sample factorial, convergent and discriminant validity were demonstrated, as well as adequate internal consistency and test-retest reliability.

  17. Universal bounds on spectral measures of one-dimensional Schrödinger operators

    CERN Document Server

    Remling, C

    2002-01-01

    Consider a Schrödinger operator $H=-d^2/dx^2+V(x)$ on $L_2(0,\\infty)$ and suppose that an initial piece of the potential $V(x)$, $0measure of intervals with a certain minimum length. This length scale is set by the eigenvalues of the problems on $[0,N]$. So in a sense (and perhaps somewhat surprisingly) the behavior of $V(x)$ becomes less important if $x$ grows. The results of this paper are developments of classical work of Chebyshev and Markov on orthogonal polynomials.

  18. The measuring system and practical uses of the universal radiation meter type TSM-11

    International Nuclear Information System (INIS)

    Rozsa, S.; Szabo, Gy.; Szem, I.; Vereczky, L.

    1980-01-01

    The industrial radiation meter in its signal conversion follows the ratemeter principle and uses pulse detectors. By its built-in zero suppression and scale extension the device makes the display of two pulses differing from each other at least by 10% and their conversion onto the output signal range of 0-20 mA possible. The information from the different measuring sections developed for industrial purposes are processed by the same device. The operation principles of and the experience gathered with the radiometer in its use in industry as density, level, thickness gauge, moisture and quantity meter and belt scales are discussed. (author)

  19. Detection of Equipment Faults Before Beam Loss

    CERN Document Server

    Galambos, J.

    2016-01-01

    High-power hadron accelerators have strict limits on fractional beam loss. In principle, once a high-quality beam is set up in an acceptable state, beam loss should remain steady. However, in practice, there are many trips in operational machines, owing to excessive beam loss. This paper deals with monitoring equipment health to identify precursor signals that indicate an issue with equipment that will lead to unacceptable beam loss. To this end, a variety of equipment and beam signal measurements are described. In particular, several operational examples from the Spallation Neutron Source (SNS) of deteriorating equipment functionality leading to beam loss are reported.

  20. Neutron scattering equipments in JAERI. Current status

    International Nuclear Information System (INIS)

    Hamaguchi, Yoshikazu; Minakawa, Nobuaki

    2003-01-01

    24 neutron scattering instruments are installed in the JRR-3M research reactor. Among them JAERI has 12 neutron scattering instruments. Those instruments are HRPD for high-resolution structural analysis, TAS-1 and TAS-2 for elastic and inelastic scattering and for magnetic scattering measurements by the polarized neutron, LTAS for elastic and inelastic scattering measurement at a low energy region, and for neutron device development, PNO for topography and for very small angle scattering measurement in a small Q range, NRG for neutron radiography, RESA for internal strain measurements, SANS for the molecule and semi-macroscopic magnetic structural analysis, BIX-2 and BIX-3 for the biological structural analysis research, and PGA for the research of prompt gamma-ray analysis. The university groups have 12 neutron scattering instruments. Since those instruments were installed at the period when JRR-3M was completed, about 10 years have passed. In order to match the old control systems with the progress of recent computer technologies, and peripheral equipment, numbers of instruments are being renewed. In the neutron guide hall of JRR-3M, the Ni mirror guide tube was replaced by a super mirror guide tube to increase neutron flux. The intensity of 2A flux was increased by a factor of about two. (J.P.N.)

  1. Measuring the Quality of Service in the Financial Area of a Public University: Development and Validation of the Instrument

    Directory of Open Access Journals (Sweden)

    Víctor Manuel Alcantar Enríquez

    2014-12-01

    Full Text Available This research, consisting of a descriptive study with a non-experimental design, involved an analysis to determine the validity and reliability of an instrument composed of seventeen items aimed at assessing the quality of service in the financial area of a public university by means of four variables: tangibility, reliability, responsiveness and empathy. The methodological strategy included the design of the measuring instrument; verification of the validity of content and construct; and analysis of internal consistency by means of Cronbach’s alpha. The instrument was applied to 152 users of the service, attaining a reliability coefficient of 0.943. The results show that with respect to specific concepts, the questions were clear; nevertheless we found it necessary to relocate items and rename variables, which resulted in a valid and reliable instrument for measuring the quality of service in the context under study.

  2. Sensor equipment of the German earth scientific airplane program

    Science.gov (United States)

    Seige, P.

    1975-01-01

    The German airplane program for earth scientific research supports the work of a vast staff of earth scientists from universities and federal agencies. Due to their fields of interest, which are in oceanography, hydrology, geology, ecology, and forestry, five test areas were selected which are spread all over Germany. The sensor package, which was designed in accordance with the requirements of this group of scientists, will be installed in a DO 28 D2 type airplane. The sensor equipment consists of a series of 70-mm cameras having different film/filter combinations, a photogrammetric camera, an infrared radiometer, an 11-channel multispectral line scanner, a LANDSAT-compatible radiometer, and a complex avionic system. Along with the airplane, a truck will be equipped with a set of radiometers and other sensor devices for extensive ground-truth measurement; this also includes a cherry picker.

  3. Measuring the topology of large-scale structure in the universe

    Science.gov (United States)

    Gott, J. Richard, III

    1988-11-01

    An algorithm for quantitatively measuring the topology of large-scale structure has now been applied to a large number of observational data sets. The present paper summarizes and provides an overview of some of these observational results. On scales significantly larger than the correlation length, larger than about 1200 km/s, the cluster and galaxy data are fully consistent with a sponge-like random phase topology. At a smoothing length of about 600 km/s, however, the observed genus curves show a small shift in the direction of a meatball topology. Cold dark matter (CDM) models show similar shifts at these scales but not generally as large as those seen in the data. Bubble models, with voids completely surrounded on all sides by wall of galaxies, show shifts in the opposite direction. The CDM model is overall the most successful in explaining the data.

  4. Measuring the topology of large-scale structure in the universe

    International Nuclear Information System (INIS)

    Gott, J.R. III

    1988-01-01

    An algorithm for quantitatively measuring the topology of large-scale structure has now been applied to a large number of observational data sets. The present paper summarizes and provides an overview of some of these observational results. On scales significantly larger than the correlation length, larger than about 1200 km/s, the cluster and galaxy data are fully consistent with a sponge-like random phase topology. At a smoothing length of about 600 km/s, however, the observed genus curves show a small shift in the direction of a meatball topology. Cold dark matter (CDM) models show similar shifts at these scales but not generally as large as those seen in the data. Bubble models, with voids completely surrounded on all sides by wall of galaxies, show shifts in the opposite direction. The CDM model is overall the most successful in explaining the data. 45 references

  5. CERN computing equipment for Senegal

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On 26 May, CERN once again had the honour of donating computing equipment to a foreign institute.   This time, around 100 servers and five network hubs were sent to Senegal, making it the seventh country, after Morocco, Ghana, Bulgaria, Serbia, Egypt and the Philippines, to receive a donation of computing equipment from the Organization. The official ceremony was held at CERN on 26 May in the presence of the Director-General, Rolf Heuer, and Senegal's ambassador to Geneva, Fodé Seck, who both expressed their enthusiasm for the project. The equipment is intended for Cheikh Anta Diop University (UCAD) in Dakar and will be of particular use to students attending the African School of Fundamental Physics and its Applications (ASP 2014) taking place from 3 to 23 August, for which CERN is a partner. The ASP allows a large number of African students to hone their skills in high-energy physics and to forge professional links with fellow physicists in Africa and Europe. ...

  6. Report on results 1998. Standardization of test measuring method of fine ceramics for communication equipment; 1998 nendo seika hokokusho. Tsushin kikiyo fine ceramics no shiken hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Technological development is in progress at present for the intelligent transport system for example that uses a microwave frequency range of 60GHz or 90GHz toward the practical use, with a demand increasing for measuring the electrical properties of fine ceramics (FC) to be used in the communication equipment of the system. The measuring method in the microwave frequency range of 30GHz or less is about to be standardized in IEC TC49/WG10; however, the method above 30GHz has not yet been examined for the standardization internationally. The subject research is intended to establish the method of measuring electrical properties such as the dielectric constant of FC for a high-frequency/ultra high-frequency wave range, dielectric loss and surface resistivity, to standardize the principle of their measuring methods, measuring tools, adjusting method of samples, procedures of measurement, etc., and to aim at the international standardization. This year, investigation and examination were carried out on various measuring methods including overseas examinations in the U.S., extracting the Fabry-Perot resonator method and a conductive cylindrical dielectric cavity resonator perturbation method for example, and evaluating the specifications of standard reference materials. In addition, a morphological technique was established for measuring sample surfaces affecting measurements, by means of an accurate measuring instrument for thin film surfaces. (NEDO)

  7. Measuring α in the early universe: CMB temperature, large-scale structure, and Fisher matrix analysis

    International Nuclear Information System (INIS)

    Martins, C. J. A. P.; Melchiorri, A.; Trotta, R.; Bean, R.; Rocha, G.; Avelino, P. P.; Viana, P. T. P.

    2002-01-01

    We extend our recent work on the effects of a time-varying fine-structure constant α in the cosmic microwave background by providing a thorough analysis of the degeneracies between α and the other cosmological parameters, and discussing ways to break these with both existing and/or forthcoming data. In particular, we present the state-of-the-art cosmic microwave background constraints on α through a combined analysis of the BOOMERanG, MAXIMA and DASI data sets. We also present a novel discussion of the constraints on α coming from large-scale structure observations, focusing in particular on the power spectrum from the 2dF survey. Our results are consistent with no variation in α from the epoch of recombination to the present day, and restrict any such variation to be less than about 4%. We show that the forthcoming Microwave Anisotropy Probe and Planck experiments will be able to break most of the currently existing degeneracies between α and other parameters, and measure α to better than percent accuracy

  8. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... energy consumption for primary electric heaters. For primary electric heaters, calculate the annual...

  9. How compliant are technicians with universal safety measures in medical laboratories in Croatia?--A pilot study.

    Science.gov (United States)

    Dukic, Kristina; Zoric, Matea; Pozaic, Petra; Starcic, Jelena; Culjak, Marija; Saracevic, Andrea; Miler, Marijana

    2015-01-01

    This pilot study aimed to investigate the use of personal protective equipment (PPE) and compliance to the code of conduct (rules defined in institutional, governmental and professional guidelines) among laboratory technicians in Croatian medical laboratories. In addition, we explored the differences in compliance between participants of different age groups, laboratory ownership and accreditation status. An anonymous and voluntary survey with 15 questions was conducted among Croatian medical laboratory technicians (N=217). The questions were divided into two groups: demographic characteristics and the use of PPE. The questions of the second part were graded according to the Likert scale (1-4) and an overall score, shown as median and range (min-max), was calculated for each participant. Differences between the overall scores were tested for each group of participants. The majority of participants always wear protective clothes at work, 38.7% of them always wear gloves in daily routine, more than 30.0% consume food and almost half of them drink beverages at workplace. A significantly lower overall score was found for participants working in public compared to private laboratories (36 (16-40) vs. 40 (31-40), Plaboratory accreditation status (P=0.081). A considerable percentage of laboratory technicians in Croatian medical laboratories do not comply with safety measures. Lack of compliance is observed in all personnel regardless laboratory accreditation and participants' age. However, those working in private laboratories adhere more to the code of conduct.

  10. Development of a universal measure of quadrupedal forelimb-hindlimb coordination using digital motion capture and computerised analysis

    Directory of Open Access Journals (Sweden)

    Jeffery Nick D

    2007-09-01

    Full Text Available Abstract Background Clinical spinal cord injury in domestic dogs provides a model population in which to test the efficacy of putative therapeutic interventions for human spinal cord injury. To achieve this potential a robust method of functional analysis is required so that statistical comparison of numerical data derived from treated and control animals can be achieved. Results In this study we describe the use of digital motion capture equipment combined with mathematical analysis to derive a simple quantitative parameter – 'the mean diagonal coupling interval' – to describe coordination between forelimb and hindlimb movement. In normal dogs this parameter is independent of size, conformation, speed of walking or gait pattern. We show here that mean diagonal coupling interval is highly sensitive to alterations in forelimb-hindlimb coordination in dogs that have suffered spinal cord injury, and can be accurately quantified, but is unaffected by orthopaedic perturbations of gait. Conclusion Mean diagonal coupling interval is an easily derived, highly robust measurement that provides an ideal method to compare the functional effect of therapeutic interventions after spinal cord injury in quadrupeds.

  11. Metrological control of instruments, equipment and measurement system for ultrasonic meters of flow; Controle metrologico de instrumentos, equipamentos e sistema de medicao para medidores ultra-sonicos de vazao

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, Oscar de

    2004-07-01

    Following the actual tendency to obtaining greater precision in Natural Gas measurement, in the past few years the use of Ultrasonic Flow Meters as Custody Transfer applications has grown significantly. There are several units currently operating in Brazil. The legislation for model approval, measure system certification and periodical metrological control of the above mentioned equipment, is currently under elaboration final stage. It was placed under public inquire through the 'Portaria 037' of 2004 of INMETRO, which proposes the authorization to perform the Metrological control by the Operator, once it has a quality system implemented according NBR ISO 9001-2000 and/or ISO 17025. This paper describes the verification procedure adopted by most of ultrasonic meters manufacturers. It also describes the application of the procedure for create the 'Metrological Control System of the Measurement System' of a 12'' Ultrasonic Meter installed and operating, with 3 years operation's data. (author)

  12. Establishment of nuclear equipment qualification system

    International Nuclear Information System (INIS)

    Joo, Po Kook; Lim, Nam Jin; Lee, Young Gun

    2003-04-01

    This study is carried out by KEARI(Korea Atomic Energy Research Institute) as the lead organization in cooperation with KIMM(Korea Institute of Machinery and Materials), KTL(Korea Testing Laboratory) and KRISS(Korea Research Institute of Standards and Science) to construct a basis of efficient management of nuclear equipment qualification business by expanding test equipment of each of participating organization, and developing qualification technologies. As for KIMM, control system of large scale shaker was replaced with advanced system, and LOCA(Loss of Coolant Accident) test facility was installed. KTL is now capable of conducting seismic tests of nuclear I and C as a result of installation of seismic test equipment during the first two project years. KRISS participated in the Project with a view to have large scale EMI test equipment and related technologies. In parallel with expansion of test equipment, a industrial-educational-research cooperation committee, as an intermediate step toward integrated equipment qualification system to maximize the usage of test equipment, was established and cooperation methods were investigated. As a result, Korea Nuclear Equipment Qualification Association, an corporate juridical person, was established. Research on development of thermal and radiation aging test technology of nuclear materials was carried out by Hanyang University and SECO(Saehan Engineering and Qualification Co., Ltd.). Integrated Equipment Qualification Database was developed which contains material test data, equipment qualification data and other EQ related informations. Standard qualification procedures were developed in order for test laboratories and manufacturers to establish design requirements and to efficiently perform tests

  13. HVAC systems and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.T. (Linford Air and Refrigeration Company, Oakland, CA (US))

    1990-02-01

    The author discusses the section of the ASHRAE Standard 90.1-1989 which addresses HVAC systems and equipment. New features of HVAC systems mandatory general requirements are described. New prescriptive requirements are detailed.

  14. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  15. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  16. CV equipment responsibilities

    CERN Document Server

    Pirollet, B

    2008-01-01

    This document describes the limits of the responsibilities of the TS/CV for fire fighting equipment at the LHC. The various interfaces, providers and users of the water supply systems and clean water raising systems are described.

  17. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  18. Longevity and Depreciation of Audiovisual Equipment.

    Science.gov (United States)

    Post, Richard

    1987-01-01

    Describes results of survey of media service directors at public universities in Ohio to determine the expected longevity of audiovisual equipment. Use of the Delphi technique for estimates is explained, results are compared with an earlier survey done in 1977, and use of spreadsheet software to calculate depreciation is discussed. (LRW)

  19. External meeting - Geneva University: Proposal to measure the muon electric dipole moment with a compact storage ring at PSI

    CERN Multimedia

    2007-01-01

    GENEVA UNIVERSITY ECOLE DE PHYSIQUE Département de physique nucléaire et corspusculaire 24, Quai Ernest-Ansermet 1211 GENEVE 4 ? Tél : 022 379 62 73 - Fax: 022 379 69 92 Wednesday 16th May  2007 PARTICLE PHYSICS SEMINAR at 17:00 - Stückelberg Auditorium Proposal to measure the muon electric dipole moment with a compact storage ring at PSI by Dr. Thomas Schietinger, PSI - Villigen In the Standard Model, lepton electric dipole moments (EDM) arise from the CP-violating phase in the CKM matrix at the three-loop level only, resulting in values that are many orders of magnitude below the sensitivity of current and future experiments. Lepton EDMs therefore offer an excellent opportunity to discover unambiguous evidence for new CP-violating phases, as called for by the baryon-antibaryon asymmetry of the universe. The muon EDM is one of the least constrained fundamental properties in elementary particle physics. We propose to utilize the large available flux of polarized muons at PSI to search for a muon EDM ...

  20. Climate to measure. Facility management for Universal Music at Berlin; Klima nach Mass. TGA-Planung fuer Universal Music in Berlin

    Energy Technology Data Exchange (ETDEWEB)

    McLead, E.A.

    2002-07-01

    Designing and constructing the technical facilities for a historical building like the 'Spreespeicher' in Berlin is a difficult but interesting task. The building is owned by Universal Music. Each department has its own office structure, and all offices and structures were integrated in a functional overall concept by the planners of Happold Ingenieure. [German] Klima, Lueftung und Elektroinstallation fuer ein historisches Gebaeude wie den Berliner Spreespeicher zu entwickeln, ist eine schwierige, aber reizvolle Aufgabe. Besonders, wenn der Nutzer Universal Music heisst: Jede Abteilung besitzt ihre eigene Buerostruktur, und alle mussten die TGA-Planer von Happold Ingenieure in ein funktionierendes Gesamtkonzept integrieren. (orig.)

  1. Electronic ground support equipment for the Cluster Electric Field and Wave Experiment

    International Nuclear Information System (INIS)

    Sten, T.A.

    1992-10-01

    In a collaboration between ESA and NASA, ionosphere plasma structures will be studied by four indentical space probes to be launched in 1995 from French Guiana. The Electric Field and Wave (EFW) experiment will be designed to measure electric field and density fluctations by means of four sensors, each deployed on a 50 meter wire boom. In order to perform comprehensive tests and calibrations of the EFW experiment, computer controlled electronic ground support equipment has been developed. This report describes the hardware of the equipment, produced and assembled at the University of Oslo. 15 figs

  2. Measurement and analysis of electromagnetic pollution generated by GSM-900 mobile phone networks in Erciyes University, Turkey.

    Science.gov (United States)

    Sorgucu, Ugur; Develi, Ibrahim

    2012-12-01

    Mobile phones are becoming increasingly important in our everyday lives. The rising number of mobile phones reflects a similar increase in the number of base stations. Because of this rapid evolution, the establishment and planning of new base stations has become mandatory. However, the rise in the number of base stations, in terms of human health, is potentially very harmful. It is important to analyze the radiation levels of base stations until we can confirm that they are definitely not harmful in the long term. Mapping of electromagnetic field (EMF) is also important from a medical point of view because it provides useful information, for example, on the detection of diseases caused by EMF. With the help of this information the distribution of diseases over different regions can be obtained. In this article, the electromagnetic radiation levels of base stations were measured at 80 different points in Erciyes University (ERU), Turkey and detailed information about the measurement tools and measurement method were given. It was observed that no area in ERU exceeded the national and international limits. It is also observed that the effects of base stations vary according to duration and degree of exposure. Therefore, if people are exposed to a very low-intensity electromagnetic field for a very long time, serious health problems can occur.

  3. Lessons learned from early direct measurements at Fukushima Medical University after the Fukushima Nuclear Power Station accident

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Makoto; Ohba, Takashi; Ohtsuru, Akira [Fukushima Medical Univ., Dept. of Radiation Health Management, Fukushima, Fukushima (Japan)

    2012-11-15

    The Fukushima Daiichi Nuclear Power Station (FDNPS) accident resulted in a month-long discharge of radioactive materials into the environment. These radioactive materials were detected at Fukushima Medical University (FMU), which is 57 km northwest of the FDNPS. Significant levels of six nuclides (i.e., {sup 131}I, {sup 132}Te, {sup 132}I, {sup 133}Xe, {sup 134}Cs, and {sup 137}Cs) were detected by a whole body counter (WBC) on March 15, 2011 when the ambient dose rate was suddenly elevated for the first time. This WBC has a dual detector system consisting of two NaI(Tl) detectors and two Ge detectors. We conducted periodical measurements of 32 humans and the background using the WBC. Because the three nuclides {sup 131}I, {sup 134}Cs and {sup 137}Cs were still detected in the background by the WBC a few months after the accident, accurate WBC measurements were difficult. Here we describe the limitations of our measurements conducted in the early stage of the FDNPS accident. (author)

  4. Measuring the impact and costs of a universal group based parenting programme: protocol and implementation of a trial

    Directory of Open Access Journals (Sweden)

    Winstanley Sarah

    2010-06-01

    Full Text Available Abstract Background Sub-optimal parenting is a common risk factor for a wide range of negative health, social and educational outcomes. Most parenting programmes have been developed in the USA in the context of delinquency prevention for targeted or indicated groups and the main theoretical underpinning for these programmes is behaviour management. The Family Links Nurturing Programme (FLNP focuses on family relationships as well as behaviour management and is offered on a universal basis. As a result it may be better placed to improve health and educational outcomes. Developed in the UK voluntary sector, FLNP is popular with practitioners, has impressed policy makers throughout the UK, has been found to be effective in before/after and qualitative studies, but lacks a randomised controlled trial (RCT evidence base. Methods/Design A multi-centre, investigator blind, randomised controlled trial of the FLNP with a target sample of 288 south Wales families who have a child aged 2-4 yrs living in or near to Flying Start/Sure Start areas. Changes in parenting, parent child relations and parent and child wellbeing are assessed with validated measures immediately and at 6 months post intervention. Economic components include cost consequences and cost utility analyses based on parental ranking of states of quality of life. Attendance and completion rates and fidelity to the FLNP course delivery are assessed. A nested qualitative study will assess reasons for participation and non-participation and the perceived value of the programme to families. By the end of May 2010, 287 families have been recruited into the trial across four areas of south Wales. Recruitment has not met the planned timescales with barriers including professional anxiety about families entering the control arm of the trial, family concern about video and audio recording, programme facilitator concern about the recording of FLNP sessions for fidelity purposes and delays due to the

  5. Development of a equipment to measure gas transport properties: Application to study candidate buffer mixtures for low-medium level waste repositories

    International Nuclear Information System (INIS)

    Martin, P. L.; Barcala, J. M.; Oller, J. C.

    2002-01-01

    This report describes the design, the construction and a testing of a system set-up for the measurement of gas transport, created at CIEMAT, and its application to study mixtures of candidate buffer materials for Low-Medium Level Waste Repertories. The measure of the gas flows is carried on by mass flow meters of several ranges, white the pressure of the applied within the sample is controlled. Two National l Instrument's acquisition system that permits the control and recording of the parameters. A specific application developed for this test, with National Instruments LabWIEW DSC, permits to mange the system. A client interface lets to follow the experiment course from a remote location through Internet. (Author) 21 refs

  6. Development of a Equipment to Measure Gas Transport Properties: Application to Study Mixtures of Candidates Buffer Materials for Low-Medium Level Waste Repositories

    Energy Technology Data Exchange (ETDEWEB)

    Martin, P.L.; Barcala, J.M.; Oller, J.C.

    2002-07-01

    This report describes the design, the construction and a testing of a system set-up for the measurement of gas transport, created at CIEMAT, and its application to study mixtures of candidate buffer materials for Low-Medium Level Waste Repertories. The measure of the gas flows is carried on by mass flow meters of several ranges, white the pressure of the applied within the sample is controlled. Two National l Instrument's acquisition system that permits the control and recording of the parameters. A specific application developed for this test, with National Instruments LabWIEW DSC, permits to mange the system. A client interface lets to follow the experiment course from a remote location through Internet. (Author) 21 refs.

  7. Survey results of output measurements in diagnostic X ray equipments using glass dosimeter and the questionnaire. Aichi association of radiological technologists 50 year anniversary memorial work

    International Nuclear Information System (INIS)

    Kondo, Yuji; Hirofuji, Yoshiaki; Saiga, Osamu; Ishibashi, Kazuto

    2003-01-01

    The Aichi Association of Radiological Technologists executed the survey according to the task of radiation control in Aichi prefecture. The survey investigated the number of clinics/hospitals who own radiation dosimeters. The association also measured outputs using glass dosimeter (GD-450) manufactured by Chiyoda Technical in diagnostic X ray. The purpose and significance of the survey are: to illustrate that the radiation control task is not involved as routine maintenance work, to examine why the task is not routinely performed, to investigate the number of clinics/hospitals who own diagnostic X ray radiation dosimeters, to inform that the use of dosimeter is essential to achieve accurate measurement for exposed dose, and to motivate the significance of radiation control in routine work. The result of the survey clearly indicated the necessity of radiation control, and suggested the information needed for the Aichi Association of Radiological Technologists to determine the guideline for the medical radiation exposed dose. (author)

  8. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  9. Prioritizing equipment for replacement.

    Science.gov (United States)

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  10. Measurement of kVp, PPV and air kerma values in function of the electric current quantity and the focus-detector distance in one X-ray equipment

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F. de; Potiens, Maria da Penha A.; Vivolo, Vitor

    2009-01-01

    The objective of this work was to study the behavior of the X-ray equipment Pantak/Seifert, model MXR-160/22 of the calibration laboratory of IPEN, LCI, operating in the diagnostic radiology radiation quality RQR 5 (70 kV). For this evaluation it was used a noninvasive meter PTW, Diavolt TM model. The measurements of kVp, PPV and Dose (air kerma), were made varying the electric current and distance between the focal point and the meter. This behavior is described in the literature and was expected in the analysis of the measurements for comparison purposes. For the tests where it was only increased the electric current it was waited a linear increase of the dose (air kerma), but not a variation in the kVp and PPV. The measurements had corresponded to the waited behavior, since the Dose (air kerma) measurements presented a linear increase with the increase of the electric current and the kVp and PPV values showed a variation less than 2%. In the corresponding measurements increasing the distance between focal point and meter, it was waited the exponentially decreasing of the Dose (air kerma) and again a small variation or no variation of the PPV and kVP with the increase of the distance. Over again the measurements corresponded to the expected, where the Dose (air kerma) decreased exponentially and the PPV and the kVp had a variation less than 1.5%. (author)

  11. Automatic monitoring of vibration welding equipment

    Science.gov (United States)

    Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

    2014-10-14

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

  12. A calibration method for the measurement of IR detector spectral responses using a FTIR spectrometer equipped with a DTGS reference cell

    Science.gov (United States)

    Gravrand, Olivier; Wlassow, J.; Bonnefond, L.

    2014-07-01

    Various high performance IR detectors are today available on the market from QWIPs to narrow gap semiconductor photodiodes, which exhibit various spectral features. In the astrophysics community, the knowledge of the detector spectral shape is of first importance. This quantity (spectral QE or response) is usually measured by means of a monochromator followed by an integrating sphere and compared to a calibrated reference detector. This approach is usually very efficient in the visible range, where all optical elements are very well known, particularly the reference detector. This setup is also widely used in the near IR (up to 3μm) but as the wavelength increases, it becomes less efficient. For instance, the internal emittance of integrating spheres in the IR, and the bad knowledge of reference detectors for longer wavelengths tend to degrade the measurement reliability. Another approach may therefore be considered, using a Fourier transform IR spectrometer (FTIR). In this case, as opposed to the monochromator, the tested detector is not in low flux condition, the incident light containing a mix of different wavelengths. Therefore, the reference detector has to be to be sensitive (and known) in the whole spectral band of interest, because it will sense all those wavelengths at the same time. A popular detector used in this case is a Deuterated Triglycine Sulfate thermal detector (DTGS). Being a pyro detetector, the spectral response of such a detector is very flat, mainly limited by its window. However, the response of such a detector is very slow, highly depending on the temporal frequency of the input signal. Moreover, being a differential detector, it doesn't work in DC. In commercial FTIR spectrometers, the source luminance is usually continuously modulated by the moving interferometer, and the result is that the interferogram mixes optical spectral information (optical path difference) and temporal variations (temporal frequency) so that the temporal

  13. Nutritional issues and self-care measures adopted by cancer patients attending a university hospital in Turkey

    Directory of Open Access Journals (Sweden)

    Sevgisun Kapucu

    2016-01-01

    Full Text Available Objective: This study aimed to assess the nutritional status of cancer patients and the self-care measures they adopted as a response to nutritional problems. Methods: This descriptive study included seventy cancer patients staying in the oncology and internal disease clinics of a university hospital in Turkey. Data were collected using a questionnaire with 29 questions. Results: The mean age of participants was 40.2 ΁ 1.82 years. Approximately, 62.9% of the patients ate only half of the meals offered to them, 65.7% experienced weight loss, and 45.7% had difficulty eating their meals on their own. Moreover, 47.1% of the patients received nutritional support and nutritional problems were observed in 71.4% of the patients; 80% were unable to eat hospital food, 54.3% had an eating disorder related to a special diet, 30% suffered from loss of appetite, 27% had nausea, and 14.3% had difficulty swallowing. Furthermore, 48.5% of patients responded that they ate home-cooked food or ordered food from outside when questioned about the self-care measures taken to avoid the aforementioned nutritional problems. Conclusions: Most of the cancer patients had serious nutritional problems and ate home-cooked food and used nutritional supplements to overcome these problems. Oncology nurses are responsible for evaluating the nutritional status of cancer patients and eliminating nutritional problems.

  14. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  15. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  16. Charging equipment. Ladegeraet

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, E

    1981-09-17

    The invention refers to a charging equipment, particularly on board charging equipment for charging traction batteries of an electric vehicle from the AC mains supply, consisting of a DC converter, which contains a controlled power transistor, a switching off unloading circuit and a power transmitter, where the secondary winding is connected in series with a rectifier diode, and a smoothing capacitor is connected in parallel with this series circuit. A converter module is provided, which consists of two DC voltage converters, whose power transistors are controlled by a control circuit in opposition with a phase displacement of 180/sup 0/.

  17. Design and testing of the measuring equipment for the detection of 71Ge and 69Ge within the gallium-solar-neutrino experiment

    International Nuclear Information System (INIS)

    Huebner, M.

    1980-01-01

    A low level measuring system has been developed for the Ga-solar-neutrino experiment, to detect the reaction 71 Ga (νsub(e),e - ) 71 Ge by the decay 71 Ge (Tsub(1/2) = 11. 4 d, 100% electron capture). An estimate based on the solar standard model gives 15 71 Ge atoms produced by solar neutrinos (pp and pep). As a monitor for background reactions in the target, the detectability of the 69 Ga (p,n) 69 Ge reaction by the decay 69 Ge (Tsub(1/2) = 39 h, 37% β + -decay, 63% electron capture) has been considered. To test the system, the detectors are mounted in a low level laboratory lead box. (orig./WB) [de

  18. A high-voltage equipment (high voltage supply, high voltage pulse generators, resonant charging inductance, synchro-instruments for gyrotron frequency measurements) for plasma applications

    International Nuclear Information System (INIS)

    Spassov, Velin

    1996-01-01

    This document reports my activities as visitor-professor at the Gyrotron Project - INPE Plasma Laboratory. The main objective of my activities was designing, construction and testing a suitable high-voltage pulse generator for plasma applications, and efforts were concentrated on the following points: Design of high-voltage resonant power supply with tunable output (0 - 50 kV) for line-type high voltage pulse generator; design of line-type pulse generator (4 microseconds pulse duration, 0 - 25 kV tunable voltage) for non linear loads such as a gyrotron and P III reactor; design of resonant charging inductance for resonant line-type pulse generator, and design of high resolution synchro instrument for gyrotron frequency measurement. (author)

  19. Detection of leaded-gasoline usage in catalyst-equipped vehicles: a gamma-ray transmission guage for measuring catalytic converter lead contamination

    International Nuclear Information System (INIS)

    Schneider, E.W.

    1982-01-01

    A gamma-ray transmission gauge has been developed for measuring the accumulation of lead inside the catalytic converters of vehicles operated on leaded gasoline. This nondestructive inspection system relates the amount of gamma radiation passing through the catalytic converter to the mass concentration of lead contained in the catalyst bed. Field studies have shown that vehicle usage of 200 L of leaded gasoline (0.34 g of Pb/L) can be detected at the 95% confidence level. Based on tests with one vehicle burning 1000 L of leaded gasoline, the accumulation rate of lead on the catalytic converter was relatively constant, accounting for 45% of the total lead consumed. Subsequent usage of unleaded gasoline resulted in no significant loss of lead from the catalytic converter

  20. Equipe de trabalho

    Directory of Open Access Journals (Sweden)

    Gabriel Gerber Hornink

    2014-08-01

    Full Text Available   Equipe de Trabalho 2014 1. Equipe editorial Editor-Chefe Bayardo Bapstista Torres, Instituto de Química - USP, Brasil Eduardo Galembeck, Departamento de Bioquímica Instituto de Biologia UNICAMP, Brasil   Editores Gabriel Gerber Hornink, Depto. Bioquímica, Instituto de Ciências Biomédicas, Universidade - Federal de Alfenas - Unifal-MG, Brasil Vera Maria Treis Trindade, Instituto de Ciências Básicas da Saúde, Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, Brasil   Corpo Editorial Adriana Cassina, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Angel Herráez, Departamento de Bioquímica y Biología molecular, Universidad de Alcalá de Henares, Madrid, Espanha André Amaral Gonçalves Bianco, Universidade Federal de São Paulo (Unifesp, Brasil Denise Vaz de Macedo, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Eneida de Paula, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Guilherme Andrade Marson, Instituto de Química - USP, Brasil Jose Antonio Martinez Oyanedel, Universidad de Concepción, Chile Josep Maria Fernández Novell, Dept. Bioquímica i Biologia Molecular Universitat de Barcelona, Espanha Leila Maria Beltramini, Instituto de Física de São Carlos, Universidade Estadual de São Paulo - USP, Brasil Manuel João da Costa, Escola de Ciências da Saúde, Universidade do Minho, Portugal Maria Lucia Bianconi, Instituto de Bioquímica Médica Universidade Federal do Rio de Janeiro (UFRJ, Brasil María Noel Alvarez, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Miguel Ángel Medina Torres, Department of Molecular Biology & Biochemistry Faculty of Sciences University of Málaga, Espanha Nelma Regina Segnini Bossolan, Instituto de Física de São Carlos, Universidade de São Paulo - USP, Brasil Paulo De Avila

  1. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    International Nuclear Information System (INIS)

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  2. Process plant equipment operation, control, and reliability

    CERN Document Server

    Holloway, Michael D; Onyewuenyi, Oliver A

    2012-01-01

    "Process Plant Equipment Book is another great publication from Wiley as a reference book for final year students as well as those who will work or are working in chemical production plants and refinery…" -Associate Prof. Dr. Ramli Mat, Deputy Dean (Academic), Faculty of Chemical Engineering, Universiti Teknologi Malaysia "…give[s] readers access to both fundamental information on process plant equipment and to practical ideas, best practices and experiences of highly successful engineers from around the world… The book is illustrated throughout with numerous black & white p

  3. Maintenence and fabrication of Electronic Equipment

    International Nuclear Information System (INIS)

    Chung, Chong Eun; Moon, Byung Soo; Hong, Suk Boong; Kim, Young Keun; Kim, Jung Bok; Lee, Sang Suk

    2004-12-01

    Development of the SPND Monitor could be the base of development of small signal processing circuits and the technique could be used to develop other precision equipment. The repair technology for high purity germanium(HPGe) detector system could be adapted to other areas where high purity detectors are used such as hospitals, universities etc. The technology of multi-channel ASIC for nuclear radiation detector, which has been imported from abroad, could be adapted to development of radiation equipment for image processing, position of detection, NDT etc., and also the technique will be expected to contribute to increase the use of radiation technology to industrial applications

  4. Division of Scientific Equipment - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2002-01-01

    allows the following tool movements in particular axes: X - 1000 mm, Y - 500 mm, Z - 500 mm; it is controlled by HEIDENHAIN 407 Control System, and ensures the accuracy and reproducibility of machining of 0.01 mm in each of the axis. In 2001 the Department of Mechanical Construction designed, manufactured and assembled an equipment for the following foreign laboratories: * Deutches Elektronen Synchrotron, Hamburg, FRG, * European Organization for Nuclear Research CERN, Geneva, Switzerland, * Forschungszentrum Karlsruhe, FRG, * Institute of Physics, Polish Academy of Science, Warsaw, Poland, * Jagiellonian University, Cracow, Poland. Besides the large designs and systems described below, some interesting works were made for the departments of our Institute and other institutions: 1. Design and manufacturing of the new photon calorimeter of Luminosity Monitor for ZEUS Experiment at DESY, 2. Manufacturing of the shutter and supporting structures for AUGER Project in Argentina, 3. Manufacturing and assembly of 105 sets of mirror positioning devices for AUGER Project in Argentina, 4. Design of ion source for cyclotron AIC-144 at our Institute, 5. Design and manufacturing of a vacuum chamber and parts of vacuum lines for dual beam ion implantator at our Institute, 6. Design and manufacturing of experimental chamber for Proton Microprobe at our Institute. (author)

  5. Equipment system for advanced nuclear fuel development

    International Nuclear Information System (INIS)

    Kwon, Hyuk Il; Ji, C. G.; Bae, S. O.

    2002-11-01

    The purpose of the settlement of equipment system for nuclear Fuel Technology Development Facility(FTDF) is to build a seismic designed facility that can accommodate handling of nuclear materials including <20% enriched Uranium and produce HANARO fuel commercially, and also to establish the advanced common research equipment essential for the research on advanced fuel development. For this purpose, this research works were performed for the settlement of radiation protection system and facility special equipment for the FTDF, and the advanced common research equipment for the fuel fabrication and research. As a result, 11 kinds of radiation protection systems such as criticality detection and alarm system, 5 kinds of facility special equipment such as environmental pollution protection system and 5 kinds of common research equipment such as electron-beam welding machine were established. By the settlement of exclusive domestic facility for the research of advanced fuel, the fabrication and supply of HANARO fuel is possible and also can export KAERI-invented centrifugal dispersion fuel materials and its technology to the nations having research reactors in operation. For the future, the utilization of the facility will be expanded to universities, industries and other research institutes

  6. 40 CFR 273.4 - Applicability-Mercury-containing equipment.

    Science.gov (United States)

    2010-07-01

    ... equipment. 273.4 Section 273.4 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.4 Applicability—Mercury...-containing components have been removed. (c) Generation of waste mercury-containing equipment. (1) Used...

  7. Audio-Visual Equipment Depreciation. RDU-75-07.

    Science.gov (United States)

    Drake, Miriam A.; Baker, Martha

    A study was conducted at Purdue University to gather operational and budgetary planning data for the Libraries and Audiovisual Center. The objectives were: (1) to complete a current inventory of equipment including year of purchase, costs, and salvage value; (2) to determine useful life data for general classes of equipment; and (3) to determine…

  8. Equipment gift to Monaco

    International Nuclear Information System (INIS)

    1970-01-01

    Research work at the Agency's Laboratory of Marine Radioactivity in Monaco, including that concerned with pollution of the sea, has been made more effective by its latest acquisition of equipment. This is a spectrophotometer donated by the Federal Republic of Germany. (author)

  9. Lifetime of Mechanical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leland, K.

    1999-07-01

    The gas plant at Kaarstoe was built as part of the Statpipe gas transport system and went on stream in 1985. In 1993 another line was routed from the Sleipner field to carry condensate, and the plant was extended accordingly. Today heavy additional supply- and export lines are under construction, and the plant is extended more than ever. The main role of the factory is to separate the raw gas into commercial products and to pump or ship it to the markets. The site covers a large number of well-known mechanical equipment. This presentation deals with piping, mechanical and structural disciplines. The lifetime of mechanical equipment is often difficult to predict as it depends on many factors, and the subject is complex. Mechanical equipment has been kept in-house, which provides detailed knowledge of the stages from a new to a 14 years old plant. The production regularity has always been very high, as required. The standard of the equipment is well kept, support systems are efficient, and human improvisation is extremely valuable.

  10. Equipping tomorrow's fire manager

    Science.gov (United States)

    Christopher A. Dicus

    2008-01-01

    Fire managers are challenged with an ever-increasing array of both responsibilities and critics. As in the past, fire managers must master the elements of fire behavior and ecology using the latest technologies. In addition, today’s managers must be equipped with the skills necessary to understand and liaise with a burgeoning group of vocal stakeholders while also...

  11. Electrical equipment design library

    International Nuclear Information System (INIS)

    1994-01-01

    This book guides the design supervision, construction order for electrical equipment. The contents of this library are let's use electricity like this, leading-in-pole and casual power, electric pole install below 300KVA, electric pole install below 301∼1000KVA, electric pole install exceed 1000KVA, rooftop install exceed 1000KVA, CUBICLE type, 154KV services. It adds an appendix.

  12. Orphee reactor experimental equipment

    International Nuclear Information System (INIS)

    1987-01-01

    Experimental equipment around the ORPHEE reactor is presented. The neutron source; and the spectrometers and sample environment (inelastic and quasi-elastic scattering, elastic scattering, spread scattering, small angle scattering) are described. An experiment proposal and reports guide is supplied [fr

  13. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  14. Underground coal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, J.

    2002-12-01

    This paper reports on increasing automation and enhanced productivity on longwalls, new development cutting and bolting technologies and haulage systems. Amongst equipment discussed is DBT's Electra series EL3000 shearer, the Dosco LH1400 roadheader with onboard bolters, and Joy 12 CM30 continuous miners. 4 photos.

  15. Health sciences students’ perception of the educational environment of KLE University, India as measured with the Dundee Ready Educational Environment Measure (DREEM

    Directory of Open Access Journals (Sweden)

    Mohan A. Sunkad

    2015-06-01

    Full Text Available This study aimed to evaluate the educational environment of the health sciences programs of KLE University, Belgaum, Karnataka, India, to identify their strengths and weaknesses, and to suggest strategies to improve the educational environment to be on par with global standards. A cross-sectional study was conducted using the Dundee Ready Educational Environment Measure (DREEM questionnaire, filled out by 914 of the 1,004 students (91.0% who were majoring in medicine, dentistry, nursing, physiotherapy, and public health. The data were analysed according to the DREEM guidelines. Responses were received from 914 students, of whom 34.03% were men and 65.9% were women. The majority (67.1% of students were 20-24 years of age. The mean overall DREEM score was 120.21±22.4 (maximum, 200 and approached the normal distribution (Lilliefors test, P<0.01. The DREEM scores of each group of students were as follows: dental, 125.0; medical, 122.4; public health, 121.0; physiotherapy, 117.0; and nursing, 116.3. Male students had more positive perceptions than female students (P<0.05, and postgraduate students had more positive perceptions than undergraduate students (P<0.05. The overall DREEM score (120.21 indicates that the educational environment was found to be more positive than negative.

  16. Type Ia Supernova Rate Measurements to Redshift 2.5 from Candles: Searching for Prompt Explosions in the Early Universe

    Science.gov (United States)

    Rodney, Steven A.; Riess, Adam G.; Strogler, Louis-Gregory; Dahlen, Tomas; Graur, Or; Casertano, Stefano; Dickinson, Mark E.; Ferguson, Henry C.; Garnavich, Peter; Cenko, Stephen Bradley

    2014-01-01

    The Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) was a multi-cycle treasury program on the Hubble Space Telescope(HST) that surveyed a total area of approx. 0.25 deg(sup 2) with approx.900 HST orbits spread across five fields over three years. Within these survey images we discovered 65 supernovae (SNe) of all types, out to z approx. 2.5. We classify approx. 24 of these as Type Ia SNe (SNe Ia) based on host galaxy redshifts and SN photometry (supplemented by grism spectroscopy of six SNe). Here we present a measurement of the volumetric SN Ia rate as a function of redshift, reaching for the first time beyond z = 2 and putting new constraints on SN Ia progenitor models. Our highest redshift bin includes detections of SNe that exploded when the universe was only approx. 3 Gyr old and near the peak of the cosmic star formation history. This gives the CANDELS high redshift sample unique leverage for evaluating the fraction of SNe Ia that explode promptly after formation (500 Myr). Combining the CANDELS rates with all available SN Ia rate measurements in the literature we find that this prompt SN Ia fraction isfP0.530.09stat0.100.10sys0.26, consistent with a delay time distribution that follows a simplet1power law for all timest40 Myr. However, mild tension is apparent between ground-based low-z surveys and space-based high-z surveys. In both CANDELS and the sister HST program CLASH (Cluster Lensing And Supernova Survey with Hubble), we find a low rate of SNe Ia at z > 1. This could be a hint that prompt progenitors are in fact relatively rare, accounting for only 20 of all SN Ia explosions though further analysis and larger samples will be needed to examine that suggestion.

  17. Ion beam stabilization in ion implantation equipment

    International Nuclear Information System (INIS)

    Pina, L.

    1973-01-01

    The results are presented of experimental efforts aimed at ion beam current stabilization in an equipment for ion implantation in solids. The related problems of power supplies are discussed. Measured characteristics of laboratory equipment served the determination of the parameters to be required of the supplies as well as the design and the construction of the supplies. The respective wiring diagram is presented. (J.K.)

  18. Protecting electrical equipment against dust explosions

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, J

    1981-07-01

    The new ordinance on electrical equipment in hazardous areas and the new VDE 0165/6.80 have brought about significant changes in the field of electrical equipment in areas with a explosion hazard due inflammable dust. There are no constructional regulations yet in this field, and producers, planners, and users are uncertain about what measures to take. The article attempts to clear up a few points.

  19. Physical protection equipment study. Final report

    International Nuclear Information System (INIS)

    Haberman, W.

    1977-06-01

    This report summarizes the work performed by MITRE for the U.S. Nuclear Regulatory Commission. The major products of this effort are a Catalog of Physical Protection Equipment, a Guide for Evaluation of Physical Protection Equipment, a book of Reference Materials, and a set of guidelines for use in the development of a methodology for measuring levels of security system effectiveness. A summary of recommendations resulting from this study is also presented

  20. An equipment test for grading lumber by transverse vibration technique

    Directory of Open Access Journals (Sweden)

    Marcelo Rodrigo Carreira

    2008-08-01

    Full Text Available Due to the great variability of its mechanical properties, the rational use of lumber for structural purposes is directly conditioned to its grading. There are several techniques available for grading structural lumber. The most relevant one is the transverse vibration technique which obtained reliable results in non-destructive evaluation of lumber. The purpose of this work is to present the bases for the mechanical grading of lumber and the results of the calibration test of the frst transverse vibration equipment developed in Brazil. In this research 30 beams of cupiúba (Goupia glabra with nominal dimensions of 5 cm X 10 cm X 300 cm, were used. The tests were accomplished at the Wood and Timber Structures Laboratory (LaMEM of the University of São Paulo (USP. The results showed a strong correlation between the elasticity modulus measured by the static bending test and the one obtained with the transverse vibration equipment, showing the high reliability of the vibration method for the grading of structural lumber. A determination coeffcient (R² of 0.896 was obtained with the Brazilian equipment, showing that it can be used in the grading of lumber.