Sample records for ultrahigh resolution ophthalmic

  1. Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography

    International Nuclear Information System (INIS)

    Unterhuber, A; Povazay, B; Bizheva, K; Hermann, B; Sattmann, H; Stingl, A; Le, T; Seefeld, M; Menzel, R; Preusser, M; Budka, H; Schubert, Ch; Reitsamer, H; Ahnelt, P K; Morgan, J E; Cowey, A; Drexler, W

    2004-01-01

    Novel ultra-broad bandwidth light sources enabling unprecedented sub-2 μm axial resolution over the 400 nm-1700 nm wavelength range have been developed and evaluated with respect to their feasibility for clinical ultrahigh resolution optical coherence tomography (UHR OCT) applications. The state-of-the-art light sources described here include a compact Kerr lens mode locked Ti:sapphire laser (λ c = 785 nm, Δλ = 260 nm, P out = 50 mW) and different nonlinear fibre-based light sources with spectral bandwidths (at full width at half maximum) up to 350 nm at λ c = 1130 nm and 470 nm at λ c = 1375 nm. In vitro UHR OCT imaging is demonstrated at multiple wavelengths in human cancer cells, animal ganglion cells as well as in neuropathologic and ophthalmic biopsies in order to compare and optimize UHR OCT image contrast, resolution and penetration depth

  2. Ultra-high resolution protein crystallography

    International Nuclear Information System (INIS)

    Takeda, Kazuki; Hirano, Yu; Miki, Kunio

    2010-01-01

    Many protein structures have been determined by X-ray crystallography and deposited with the Protein Data Bank. However, these structures at usual resolution (1.5< d<3.0 A) are insufficient in their precision and quantity for elucidating the molecular mechanism of protein functions directly from structural information. Several studies at ultra-high resolution (d<0.8 A) have been performed with synchrotron radiation in the last decade. The highest resolution of the protein crystals was achieved at 0.54 A resolution for a small protein, crambin. In such high resolution crystals, almost all of hydrogen atoms of proteins and some hydrogen atoms of bound water molecules are experimentally observed. In addition, outer-shell electrons of proteins can be analyzed by the multipole refinement procedure. However, the influence of X-rays should be precisely estimated in order to derive meaningful information from the crystallographic results. In this review, we summarize refinement procedures, current status and perspectives for ultra high resolution protein crystallography. (author)

  3. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

    Science.gov (United States)

    Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  4. Measurement of the Retention Time of Different Ophthalmic Formulations with Ultrahigh-Resolution Optical Coherence Tomography.

    Science.gov (United States)

    Gagliano, Caterina; Papa, Vincenzo; Amato, Roberta; Malaguarnera, Giulia; Avitabile, Teresio

    2018-04-01

    Purpose/aim of the study: The purpose of this study was to measure the pre-corneal retention time of two marketed formulations (eye drops and eye gel) of a steroid-antibiotic fixed combination (FC) containing 0.1% dexamethasone and 0.3% netilmicin. Pre-corneal retention time was evaluated in 16 healthy subjects using an ultrahigh-resolution anterior segment spectral domain optical coherence tomography (OCT). All subjects randomly received both formulations of the FC (Netildex, SIFI, Italy). Central tear film thickness (CTFT) was measured before instillation (time 0) and then after 1, 10, 20, 30, 40 50, 60 and 120 min. The pre-corneal retention time was calculated by plotting CTFT as a function of time. Differences between time points and groups were analyzed by Student's t-test. CTFT increased significantly after the instillation of the eye gel formulation (p < 0.001). CTFT reached its maximum value 1 min after instillation and returned to baseline after 60 min. No effect on CTFT was observed after the instillation of eye drops. The difference between the two formulations was statistically significant at time 1 min (p < 0.0001), 10 min (p < 0.001) and 20 min (p < 0.01). The FC formulated as eye gel was retained on the ocular surface longer than the corresponding eye drop solution. Consequently, the use of the eye gel might extend the interval between instillations and decrease the frequency of administration.

  5. Design and Implementation of Wideband Exciter for an Ultra-high Resolution Airborne SAR System

    Directory of Open Access Journals (Sweden)

    Jia Ying-xin

    2013-03-01

    Full Text Available According to an ultra-high resolution airborne SAR system with better than 0.1 m resolution, a wideband Linear Frequency Modulated (LFM pulse compression exciter with 14.8 GHz carrier and 3.2 GHz bandwidth is designed and implemented. The selection of signal generation scheme and some key technique points for wideband LFM waveform is presented in detail. Then, an acute test and analysis of the LFM signal is performed. The final airborne experiments demonstrate the validity of the LFM source which is one of the subsystems in an ultra-high resolution airborne SAR system.

  6. Motivation for an SSC detector with ultra-high resolution photon detection

    International Nuclear Information System (INIS)

    Gunion, J.F.; Kane, G.

    1992-01-01

    It is well known that incorporating ultra-high resolution photon detection into a general purpose detector for the SSC will be extremely difficult. The authors will argue that the physics signals that could be missed without such resolution are of such importance that a special purpose detector designed specifically for photon final state modes should be constructed, if sufficient resolution cannot be achieved with general purpose detectors. The potentially great value of these signals as a probe of extremely high mass scales is stressed

  7. Optimization of Monochromated TEM for Ultimate Resolution Imaging and Ultrahigh Resolution Electron Energy Loss Spectroscopy

    KAUST Repository

    Lopatin, Sergei; Cheng, Bin; Liu, Wei-Ting; Tsai, Meng-Lin; He, Jr-Hau; Chuvilin, Andrey

    2017-01-01

    The performance of a monochromated transmission electron microscope with Wien type monochromator is optimized to achieve an extremely narrow energy spread of electron beam and an ultrahigh energy resolution with spectroscopy. The energy spread in the beam is improved by almost an order of magnitude as compared to specified values. The optimization involves both the monochromator and the electron energy loss detection system. We demonstrate boosted capability of optimized systems with respect to ultra-low loss EELS and sub-angstrom resolution imaging (in a combination with spherical aberration correction).

  8. Optimization of Monochromated TEM for Ultimate Resolution Imaging and Ultrahigh Resolution Electron Energy Loss Spectroscopy

    KAUST Repository

    Lopatin, Sergei

    2017-09-01

    The performance of a monochromated transmission electron microscope with Wien type monochromator is optimized to achieve an extremely narrow energy spread of electron beam and an ultrahigh energy resolution with spectroscopy. The energy spread in the beam is improved by almost an order of magnitude as compared to specified values. The optimization involves both the monochromator and the electron energy loss detection system. We demonstrate boosted capability of optimized systems with respect to ultra-low loss EELS and sub-angstrom resolution imaging (in a combination with spherical aberration correction).

  9. Ultrahigh resolution radiation imaging system using an optical fiber structure scintillator plate.

    Science.gov (United States)

    Yamamoto, Seiichi; Kamada, Kei; Yoshikawa, Akira

    2018-02-16

    High resolution imaging of radiation is required for such radioisotope distribution measurements as alpha particle detection in nuclear facilities or high energy physics experiments. For this purpose, we developed an ultrahigh resolution radiation imaging system using an optical fiber structure scintillator plate. We used a ~1-μm diameter fiber structured GdAlO 3 :Ce (GAP) /α-Al 2 O 3 scintillator plate to reduce the light spread. The fiber structured scintillator plate was optically coupled to a tapered optical fiber plate to magnify the image and combined with a lens-based high sensitivity CCD camera. We observed the images of alpha particles with a spatial resolution of ~25 μm. For the beta particles, the images had various shapes, and the trajectories of the electrons were clearly observed in the images. For the gamma photons, the images also had various shapes, and the trajectories of the secondary electrons were observed in some of the images. These results show that combining an optical fiber structure scintillator plate with a tapered optical fiber plate and a high sensitivity CCD camera achieved ultrahigh resolution and is a promising method to observe the images of the interactions of radiation in a scintillator.

  10. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

    International Nuclear Information System (INIS)

    Gupta, Rajiv; Brady, Tom; Grasruck, Michael; Suess, Christoph; Schmidt, Bernhard; Stierstorfer, Karl; Popescu, Stefan; Flohr, Thomas; Bartling, Soenke H.

    2006-01-01

    Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT). (orig.)

  11. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Rajiv; Brady, Tom [Massachusetts General Hospital, Department of Radiology, Founders House, FND-2-216, Boston, MA (United States); Grasruck, Michael; Suess, Christoph; Schmidt, Bernhard; Stierstorfer, Karl; Popescu, Stefan; Flohr, Thomas [Siemens Medical Solutions, Forchheim (Germany); Bartling, Soenke H. [Hannover Medical School, Department of Neuroradiology, Hannover (Germany)

    2006-06-15

    Digital flat-panel-based volume CT (VCT) represents a unique design capable of ultra-high spatial resolution, direct volumetric imaging, and dynamic CT scanning. This innovation, when fully developed, has the promise of opening a unique window on human anatomy and physiology. For example, the volumetric coverage offered by this technology enables us to observe the perfusion of an entire organ, such as the brain, liver, or kidney, tomographically (e.g., after a transplant or ischemic event). By virtue of its higher resolution, one can directly visualize the trabecular structure of bone. This paper describes the basic design architecture of VCT. Three key technical challenges, viz., scatter correction, dynamic range extension, and temporal resolution improvement, must be addressed for successful implementation of a VCT scanner. How these issues are solved in a VCT prototype and the modifications necessary to enable ultra-high resolution volumetric scanning are described. The fundamental principles of scatter correction and dose reduction are illustrated with the help of an actual prototype. The image quality metrics of this prototype are characterized and compared with a multi-detector CT (MDCT). (orig.)

  12. Development of ultrahigh energy resolution gamma spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Drury, O.B.; Velazquez, M.; Dreyer, J.G.; Friedrich, S.

    2009-01-01

    We are developing superconducting ultrahigh resolution gamma-detectors for non-destructive analysis (NDA) of nuclear materials, and specifically for spent fuel characterization in nuclear safeguards. The detectors offer an energy resolution below 100 eV FWHM at 100 keV, and can therefore significantly increase the precision of NDA at low energies where line overlap affects the errors of the measurement when using germanium detectors. They also increase the peak-to-background ratio and thus improve the detection limits for weak gamma emissions from the fissile Pu and U isotopes at low energy in the presence of an intense Compton background from the fission products in spent fuel. Here we demonstrate high energy resolution and high peak-to-background ratio of our superconducting Gamma detectors, and discuss their relevance for measuring actinides in spent nuclear fuel. (author)

  13. Ultra-high resolution optical coherence tomography for encapsulation quality inspection

    KAUST Repository

    Czajkowski, Jakub

    2011-08-28

    We present the application of ultra-high resolution optical coherence tomography (UHR-OCT) in evaluation of thin, protective films used in printed electronics. Two types of sample were investigated: microscopy glass and organic field effect transistor (OFET) structure. Samples were coated with thin (1-3 μm) layer of parylene C polymer. Measurements were done using experimental UHR-OCT device based on a Kerr-lens mode locked Ti: sapphire femtosecond laser, photonic crystal fibre and modified, free-space Michelson interferometer. Submicron resolution offered by the UHR-OCT system applied in the study enables registration of both interfaces of the thin encapsulation layer. Complete, volumetric characterisation of protective layers is presented, demonstrating possibility to use OCT for encapsulation quality inspection. © Springer-Verlag 2011.

  14. Visible-to-visible four-photon ultrahigh resolution microscopic imaging with 730-nm diode laser excited nanocrystals.

    Science.gov (United States)

    Wang, Baoju; Zhan, Qiuqiang; Zhao, Yuxiang; Wu, Ruitao; Liu, Jing; He, Sailing

    2016-01-25

    Further development of multiphoton microscopic imaging is confronted with a number of limitations, including high-cost, high complexity and relatively low spatial resolution due to the long excitation wavelength. To overcome these problems, for the first time, we propose visible-to-visible four-photon ultrahigh resolution microscopic imaging by using a common cost-effective 730-nm laser diode to excite the prepared Nd(3+)-sensitized upconversion nanoparticles (Nd(3+)-UCNPs). An ordinary multiphoton scanning microscope system was built using a visible CW diode laser and the lateral imaging resolution as high as 161-nm was achieved via the four-photon upconversion process. The demonstrated large saturation excitation power for Nd(3+)-UCNPs would be more practical and facilitate the four-photon imaging in the application. A sample with fine structure was imaged to demonstrate the advantages of visible-to-visible four-photon ultrahigh resolution microscopic imaging with 730-nm diode laser excited nanocrystals. Combining the uniqueness of UCNPs, the proposed visible-to-visible four-photon imaging would be highly promising and attractive in the field of multiphoton imaging.

  15. Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Stephen [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-19

    The goal of this LCP is to develop ultra-high resolution gamma detectors based on magnetic microcalorimeters (MMCs) for accurate non-destructive analysis (NDA) of nuclear materials. For highest energy resolution, we will introduce erbium-doped silver (Ag:Er) as a novel sensor material, and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. Since best MMC performance requires detector operation at ~10 mK, we will purchase a dilution refrigerator with a base temperature <10 mK and adapt it for MMC operation. The detector performance will be tested with radioactive sources of interest to the safeguards community.

  16. USING A MICRO-UAV FOR ULTRA-HIGH RESOLUTION MULTI-SENSOR OBSERVATIONS OF ANTARCTIC MOSS BEDS

    Directory of Open Access Journals (Sweden)

    A. Lucieer

    2012-07-01

    Full Text Available This study is the first to use an Unmanned Aerial Vehicle (UAV for mapping moss beds in Antarctica. Mosses can be used as indicators for the regional effects of climate change. Mapping and monitoring their extent and health is therefore important. UAV aerial photography provides ultra-high resolution spatial data for this purpose. We developed a technique to extract an extremely dense 3D point cloud from overlapping UAV aerial photography based on structure from motion (SfM algorithms. The combination of SfM and patch-based multi-view stereo image vision algorithms resulted in a 2 cm resolution digital terrain model (DTM. This detailed topographic information combined with vegetation indices derived from a 6-band multispectral sensor enabled the assessment of moss bed health. This novel UAV system has allowed us to map different environmental characteristics of the moss beds at ultra-high resolution providing us with a better understanding of these fragile Antarctic ecosystems. The paper provides details on the different UAV instruments and the image processing framework resulting in DEMs, vegetation indices, and terrain derivatives.

  17. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    International Nuclear Information System (INIS)

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-01-01

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution

  18. Development of an ultrahigh-resolution Si-PM-based dual-head GAGG coincidence imaging system

    Science.gov (United States)

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Kato, Katsuhiko; Hatazawa, Jun

    2013-03-01

    A silicon photomultiplier (Si-PM) is a promising photodetector for high resolution PET systems due to its small channel size and high gain. Using Si-PMs, it will be possible to develop a high resolution imaging systems. For this purpose, we developed a small field-of-view (FOV) ultrahigh-resolution Si-PM-based dual-head coincidence imaging system for small animals and plant research. A new scintillator, Ce doped Gd3Al12Ga3O12 (GAGG), was selected because of its high light output and its emission wavelength matched with the Si-PM arrays and contained no radioactivity. Each coincidence imaging block detector consists of 0.5×0.5×5 mm3 GAGG pixels combined with a 0.1-mm thick reflector to form a 20×17 matrix that was optically coupled to a Si-PM array (Hamamatsu MPPC S11064-050P) with a 1.5-mm thick light guide. The GAGG block size was 12.0×10.2 mm2. Two GAGG block detectors were positioned face to face and set on a flexible arm based detector stand. All 0.5 mm GAGG pixels in the block detectors were clearly resolved in the 2-dimensional position histogram. The energy resolution was 14.4% FWHM for the Cs-137 gamma ray. The spatial resolution was 0.7 mm FWHM measured using a 0.25 mm diameter Na-22 point source. Small animal and plant images were successfully obtained. We conclude that our developed ultrahigh-resolution Si-PM-based dual-head coincidence imaging system is promising for small animal and plant imaging research.

  19. Bulk superconducting gap of V_3Si studied by low-energy ultrahigh-resolution photoemission spectroscopy

    International Nuclear Information System (INIS)

    Sato, T.; Souma, S.; Nakayama, K.; Sugawara, K.; Toyota, N.; Takahashi, T.

    2016-01-01

    Highlights: • We report ultrahigh-resolution photoemission spectroscopy of A15 compound V_3Si. • We found a sharp quasiparticle peak due to superconducting-gap opening. • The surface metallic component is negligibly small in the bulk-sensitive measurement. • We show that V_3Si is a single-gap s-wave superconductor. - Abstract: We have performed low-energy ultrahigh-resolution photoemission spectroscopy (PES) of A15 compound V_3Si with a xenon-plasma discharge lamp to elucidate the bulk superconducting gap. Below the superconducting transition temperature (T_c = 15.9 K), we found a sharp quasiparticle peak at the Fermi level in the PES spectrum. The gap spectrum is well fitted by a single s-wave superconducting-gap function together with a dip structure at ∼30 meV suggestive of a strong electron-phonon coupling. The anomalous in-gap state previously observed in the PES measurement with high-energy photons is absent or negligibly small in the present bulk-sensitive measurement. The present PES result shows that V_3Si is a single-gap s-wave superconductor.

  20. High resolution, high speed ultrahigh vacuum microscopy

    International Nuclear Information System (INIS)

    Poppa, Helmut

    2004-01-01

    The history and future of transmission electron microscopy (TEM) is discussed as it refers to the eventual development of instruments and techniques applicable to the real time in situ investigation of surface processes with high resolution. To reach this objective, it was necessary to transform conventional high resolution instruments so that an ultrahigh vacuum (UHV) environment at the sample site was created, that access to the sample by various in situ sample modification procedures was provided, and that in situ sample exchanges with other integrated surface analytical systems became possible. Furthermore, high resolution image acquisition systems had to be developed to take advantage of the high speed imaging capabilities of projection imaging microscopes. These changes to conventional electron microscopy and its uses were slowly realized in a few international laboratories over a period of almost 40 years by a relatively small number of researchers crucially interested in advancing the state of the art of electron microscopy and its applications to diverse areas of interest; often concentrating on the nucleation, growth, and properties of thin films on well defined material surfaces. A part of this review is dedicated to the recognition of the major contributions to surface and thin film science by these pioneers. Finally, some of the important current developments in aberration corrected electron optics and eventual adaptations to in situ UHV microscopy are discussed. As a result of all the path breaking developments that have led to today's highly sophisticated UHV-TEM systems, integrated fundamental studies are now possible that combine many traditional surface science approaches. Combined investigations to date have involved in situ and ex situ surface microscopies such as scanning tunneling microscopy/atomic force microscopy, scanning Auger microscopy, and photoemission electron microscopy, and area-integrating techniques such as x-ray photoelectron

  1. Photoionization study of doubly-excited helium at ultra-high resolution

    Energy Technology Data Exchange (ETDEWEB)

    Kaindl, G.; Schulz, K.; Domke, M. [Freie Universitaet Berlin (Germany)] [and others

    1997-04-01

    Ever since the pioneering work of Madden & Codling and Cooper, Fano & Prats on doubly-excited helium in the early sixties, this system may be considered as prototypical for the study of electron-electron correlations. More detailed insight into these states could be reached only much later, when improved theoretical calculations of the optically-excited {sup 1}P{sup 0} double-excitation states became available and sufficiently high energy resolution ({delta}E=4.0 meV) was achieved. This allowed a systematic investigation of the double-excitation resonances of He up to excitation energies close to the double-ionization threshold, I{sub infinity}=79.003 eV, which stimulated renewed theoretical interest into these correlated electron states. The authors report here on striking progress in energy resolution in this grazing-incidence photon-energy range of grating monochromators and its application to hitherto unobservable states of doubly-excited He. By monitoring an extremely narrow double-excitation resonance of He, with a theoretical lifetime width of less than or equal to 5 {mu}eV, a resolution of {delta}E=1.0 meV (FWHM) at 64.1 eV could be achieved. This ultra-high spectral resolution, combined with high photon flux, allowed the investigation of new Rydberg resonances below the N=3 ionization threshold, I{sub 3}, as well as a detailed comparison with ab-initio calculations.

  2. Argentation chromatography coupled to ultrahigh-resolution mass spectrometry for the separation of a heavy crude oil.

    Science.gov (United States)

    Molnárné Guricza, Lilla; Schrader, Wolfgang

    2017-02-10

    Simplification of highly complex mixtures such as crude oil by using chromatographic methods makes it possible to get more detailed information about the composition of the analyte. Separation by argentation chromatography can be achieved based on the interaction of different strength between the silver ions (Ag + ) immobilized through a spacer on the silica gel surface and the π-bonds of the analytes. Heavy crude oils contain compounds with a high number of heteroatoms (N, O, S) and a high degree of unsaturation thus making them the perfect analyte for argentation chromatography. The direct coupling of argentation chromatography and ultrahigh-resolution mass spectrometry allows to continuously tracking the separation of the many different compounds by retention time and allows sensitive detection on a molecular level. Direct injection of a heavy crude oil into a ultrahigh-resolution mass spectrometer showed components with DBE of up to 25, whereas analytes with DBE of up to 35 could be detected only after separation with argentation chromatography. The reduced complexity achieved by the separation helps increasing the information depth. Copyright © 2016. Published by Elsevier B.V.

  3. Electron attachment to oxygen, ozone and other compounds of atmospheric relevance as studied with ultra-high energy resolution

    International Nuclear Information System (INIS)

    Maerk, T.D.; Matejcik, S.; Kiendler, A.; Cicman, P.; Senn, G.; Skalny, J.; Stampfli, P.; Illenberger, E.; Chu, Y.; Stamatovic, A.

    1996-01-01

    The processes of electron attachment to oxygen, ozone, ozone/oxygen cluster and oxygen cluster as well as other compounds of atmospheric relevance (CF 2 Cl 2 , CHCl 3 and CCl 3 Br) were studied with ultra-high energy resolution crossed beam technique

  4. Microstructural abnormalities in MEWDS demonstrated by ultrahigh resolution optical coherence tomography.

    Science.gov (United States)

    Nguyen, My Hanh T; Witkin, Andre J; Reichel, Elias; Ko, Tony H; Fujimoto, James G; Schuman, Joel S; Duker, Jay S

    2007-01-01

    Histopathological studies of acute multiple evanescent white dot syndrome (MEWDS) have not been reported because of the transient and benign nature of the disease. Ultrahigh resolution optical coherence tomography (UHR-OCT), capable of high resolution in vivo imaging, offers a unique opportunity to visualize retinal microstructure in the disease. UHR-OCT images of the maculae of five patients with MEWDS were obtained and analyzed. Diagnosis was based on clinical presentation, examination, visual field testing, and angiography. UHR-OCT revealed disturbances in the photoreceptor inner/outer segment junction (IS/OS) in each of the five patients (six eyes) with MEWDS. In addition, thinning of the outer nuclear layer was seen in the case of recurrent MEWDS, suggesting that repeated episodes of MEWDS may result in photoreceptor atrophy. Subtle disruptions of the photoreceptor IS/OS are demonstrated in all eyes affected by MEWDS. UHR-OCT may be a useful adjunct to diagnosis and monitoring of MEWDS.

  5. Quantifying the benefits of ultrahigh energy resolution for Gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Drury, Owen B.; Terracol, Stephane F.; Friedrich, Stephan [Advanced Detector Group, Lawrence Livermore National Laboratory, L-270, Livermore CA 94550 (United States)

    2005-03-01

    Cryogenic Gamma-ray spectrometers operating at temperatures of {proportional_to}0.1 K provide an order of magnitude better energy resolution than conventional germanium detectors. Ultra-high energy resolution improves the accuracy of non-destructive analysis of nuclear materials, since a better separation of lines reduces statistical errors as well as systematic errors from background subtraction and efficiency correction. We are developing cryogenic Gamma-spectrometers based on bulk tin absorbers and superconducting molybdenum-copper sensors for nuclear forensics and non-proliferation applications. Here we quantify the improvements in accuracy for isotope analysis with cryogenic detectors in terms of detector performance for different cases of line separation, line intensity ratios and background levels. Precise measurements of isotope ratios are crucial in the context of nuclear attribution, since they provide signatures of composition, age, origin, intended purpose and processing history of illicit nuclear materials. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Precision mechanical design of an ultrahigh-resolution inelastic x-ray scattering spectrometer system with CDFDW optics at the APS

    International Nuclear Information System (INIS)

    Shu, D; Stoupin, S; Khachatryan, R; Goetze, K A; Roberts, T; Shvyd'ko, Y; Mundboth, K; Collins, S

    2013-01-01

    There are many scientific applications, especially involving topics related to the equilibrium atomic-scale dynamics of condensed matter, that require both a narrower and a steeper resolution function and access to a broader dynamic range than are currently available. To meet these important scientific needs, a prototype of a novel ultrahigh-resolution inelastic x-ray scattering spectrometer system has been designed and constructed at undulator-based beamline 30-ID at the Advanced Photon Source, Argonne National Laboratory. This prototype is designed to meet challenging mechanical and optical specifications for performing so-called CDFDW angular-dispersive x-ray crystal optics, which include a central ultra-thin CFW crystal and a pair of dispersing elements. The abbreviation CDFDW stands for: C – collimating crystal, D – dispersing-element crystal (two D-crystals are used in each CDFDW), F – anomalous transmission filter, and W – wavelength-selector crystal [1]. The mechanical design of the ultrahigh-resolution inelastic x-ray scattering spectrometer, as well as the preliminary test results of its precision positioning performance are presented in this paper.

  7. Comparative study between ultrahigh spatial frequency algorithm and high spatial frequency algorithm in high-resolution CT of the lungs

    International Nuclear Information System (INIS)

    Oh, Yu Whan; Kim, Jung Kyuk; Suh, Won Hyuck

    1994-01-01

    To date, the high spatial frequency algorithm (HSFA) which reduces image smoothing and increases spatial resolution has been used for the evaluation of parenchymal lung diseases in thin-section high-resolution CT. In this study, we compared the ultrahigh spatial frequency algorithm (UHSFA) with the high spatial frequency algorithm in the assessment of thin section images of the lung parenchyma. Three radiologists compared the UHSFA and HSFA on identical CT images in a line-pair resolution phantom, one lung specimen, 2 patients with normal lung and 18 patients with abnormal lung parenchyma. Scanning of a line-pair resolution phantom demonstrated no difference in resolution between two techniques but it showed that outer lines of the line pairs with maximal resolution looked thicker on UHSFA than those on HSFA. Lung parenchymal detail with UHSFA was judged equal or superior to HSFA in 95% of images. Lung parenchymal sharpness was improved with UHSFA in all images. Although UHSFA resulted in an increase in visible noise, observers did not found that image noise interfered with image interpretation. The visual CT attenuation of normal lung parenchyma is minimally increased in images with HSFA. The overall visual preference of the images reconstructed on UHSFA was considered equal to or greater than that of those reconstructed on HSFA in 78% of images. The ultrahigh spatial frequency algorithm improved the overall visual quality of the images in pulmonary parenchymal high-resolution CT

  8. Bulk superconducting gap of V{sub 3}Si studied by low-energy ultrahigh-resolution photoemission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T., E-mail: t-sato@arpes.phys.tohoku.ac.jp [Department of Physics, Tohoku University, Sendai 980-8578 (Japan); Souma, S. [WPI Research Center, Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan); Nakayama, K. [Department of Physics, Tohoku University, Sendai 980-8578 (Japan); Sugawara, K. [WPI Research Center, Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan); Toyota, N. [Department of Physics, Tohoku University, Sendai 980-8578 (Japan); Takahashi, T. [Department of Physics, Tohoku University, Sendai 980-8578 (Japan); WPI Research Center, Advanced Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2016-04-15

    Highlights: • We report ultrahigh-resolution photoemission spectroscopy of A15 compound V{sub 3}Si. • We found a sharp quasiparticle peak due to superconducting-gap opening. • The surface metallic component is negligibly small in the bulk-sensitive measurement. • We show that V{sub 3}Si is a single-gap s-wave superconductor. - Abstract: We have performed low-energy ultrahigh-resolution photoemission spectroscopy (PES) of A15 compound V{sub 3}Si with a xenon-plasma discharge lamp to elucidate the bulk superconducting gap. Below the superconducting transition temperature (T{sub c} = 15.9 K), we found a sharp quasiparticle peak at the Fermi level in the PES spectrum. The gap spectrum is well fitted by a single s-wave superconducting-gap function together with a dip structure at ∼30 meV suggestive of a strong electron-phonon coupling. The anomalous in-gap state previously observed in the PES measurement with high-energy photons is absent or negligibly small in the present bulk-sensitive measurement. The present PES result shows that V{sub 3}Si is a single-gap s-wave superconductor.

  9. Microscope-Integrated Intraoperative Ultrahigh-Speed Swept-Source Optical Coherence Tomography for Widefield Retinal and Anterior Segment Imaging.

    Science.gov (United States)

    Lu, Chen D; Waheed, Nadia K; Witkin, Andre; Baumal, Caroline R; Liu, Jonathan J; Potsaid, Benjamin; Joseph, Anthony; Jayaraman, Vijaysekhar; Cable, Alex; Chan, Kinpui; Duker, Jay S; Fujimoto, James G

    2018-02-01

    To demonstrate the feasibility of retinal and anterior segment intraoperative widefield imaging using an ultrahigh-speed, swept-source optical coherence tomography (SS-OCT) surgical microscope attachment. A prototype post-objective SS-OCT using a 1,050-nm wavelength, 400 kHz A-scan rate, vertical cavity surface-emitting laser (VCSEL) light source was integrated to a commercial ophthalmic surgical microscope after the objective. Each widefield OCT data set was acquired in 3 seconds (1,000 × 1,000 A-scans, 12 × 12 mm 2 for retina and 10 × 10 mm 2 for anterior segment). Intraoperative SS-OCT was performed in 20 eyes of 20 patients. In six of seven membrane peels and five of seven rhegmatogenous retinal detachment repair surgeries, widefield retinal imaging enabled evaluation pre- and postoperatively. In all seven cataract cases, anterior imaging evaluated the integrity of the posterior lens capsule. Ultrahigh-speed SS-OCT enables widefield intraoperative viewing in the posterior and anterior eye. Widefield imaging visualizes ocular structures and pathology without requiring OCT realignment. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:94-102.]. Copyright 2018, SLACK Incorporated.

  10. A Liquid-Cryogen-Free Cryostat for Ultrahigh Resolution Gamma-Ray Spectrometers

    International Nuclear Information System (INIS)

    Dreyer, J.G.; Hertrich, T.; Drury, O.B.; Hohne, J.; Friedrich, S.

    2008-01-01

    We are developing ultra-high energy resolution gamma-ray detectors based on superconducting transition edge sensors (TESs) for nuclear non-proliferation and fundamental science applications. They use bulk tin absorbers attached to molybdenum-copper multilayer TESs, and have achieved an energy resolution between 50 and 90 eV FWHM for gamma-ray energies below 122 keV. For increased user-friendliness, we have built a cryostat that attains the required detector operating temperature of 0.1 K at the push of a button without the use of cryogenic liquids. It uses a two-stage mechanical pulse tube refrigerator for precooling to ∼3 K, and a two-stage adiabatic demagnetization refrigerator for cooling to the base temperature. The cryostat is fully automated, attains a base temperature below 30 mK without the use of cryogenic liquids, and has a hold time of ∼2 days at 0.1 K between 1-hour demagnetization cycles. Here we discuss the performance of the cryostat for operation in a Gamma-spectrometer with 112-pixel arrays of superconducting TES detectors

  11. Simultaneous dual wavelength eye-tracked ultrahigh resolution retinal and choroidal optical coherence tomography

    DEFF Research Database (Denmark)

    Unterhuber, A.; Povaay, B.; Müller, André

    2013-01-01

    We demonstrate an optical coherence tomography device that simultaneously combines different novel ultrabroad bandwidth light sources centered in the 800 and 1060 nm regions, operating at 66 kHz depth scan rate, and a confocal laser scanning ophthalmoscope-based eye tracker to permit motion......-artifact-free, ultrahigh resolution and high contrast retinal and choroidal imaging. The two wavelengths of the device provide the complementary information needed for diagnosis of subtle retinal changes, while also increasing visibility of deeper-lying layers to image pathologies that include opaque media in the anterior...... eye segment or eyes with increased choroidal thickness....

  12. Evaluation of TSE- and T1-3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT

    International Nuclear Information System (INIS)

    Stork, A.; Schulze, D.; Koops, A.; Kemper, J.; Adam, G.

    2002-01-01

    Purpose: Evaluation of TSE- and T 1 -3D-GRE-sequences for focal cartilage lesions in vitro in comparison to ultrahigh resolution multi-slice CT. Materials and methods: Forty artificial cartilage lesions in ten bovine patellae were immersed in a solution of iodinated contrast medium and assessed with ultrahigh resolution multi-slice CT. Fat-suppressed TSE images with intermediate- and T 2 -weighting at a slice thickness of 2, 3 and 4 mm as well as fat-suppressed T 1 -weighted 3D-FLASH images with an effective slice thickness of 1, 2 and 3 mm were acquired at 1.5 T. After adding Gd-DTPA to the saline solution containing the patellae, the T 1 -weighted 3D-FLASH imaging was repeated. Results: All cartilage lesions were visualised and graded with ultrahigh resolution multi-slice CT. The TSE images had a higher sensitivity and a higher inter- and intraobserver kappa compared to the FLASH-sequences (TSE: 70-95%; 0.82-0.83; 0.85-0.9; FLASH: 57.5-85%; 0.53-0.72; 0.73-0.82, respectively). An increase in slice thickness decreased the sensitivity, whereby deep lesions were even reliably depicted on TSE images at a slice thickness of 3 and 4 mm. Adding Gd-DTPA to the saline solution increased the sensitivity by 10% with no detectable advantage over the T 2 -weighted TSE images. Conclusion: TSE sequences and application of Gd-DTPA seemed to be superior to T 1 -weighted 3D-FLASH sequences without Gd-DTPA in the detection of focal cartilage lesions. The ultrahigh resolution multi-slice CT can serve as in vitro reference standard for focal cartilage lesions. (orig.) [de

  13. High-resolution mapping of linear antibody epitopes using ultrahigh-density peptide microarrays

    DEFF Research Database (Denmark)

    Buus, Søren; Rockberg, Johan; Forsström, Björn

    2012-01-01

    Antibodies empower numerous important scientific, clinical, diagnostic, and industrial applications. Ideally, the epitope(s) targeted by an antibody should be identified and characterized, thereby establishing antibody reactivity, highlighting possible cross-reactivities, and perhaps even warning...... against unwanted (e.g. autoimmune) reactivities. Antibodies target proteins as either conformational or linear epitopes. The latter are typically probed with peptides, but the cost of peptide screening programs tends to prohibit comprehensive specificity analysis. To perform high-throughput, high......-resolution mapping of linear antibody epitopes, we have used ultrahigh-density peptide microarrays generating several hundred thousand different peptides per array. Using exhaustive length and substitution analysis, we have successfully examined the specificity of a panel of polyclonal antibodies raised against...

  14. Diclofenac Ophthalmic

    Science.gov (United States)

    Diclofenac ophthalmic solution is used to treat eye pain, redness, and swelling in patients who are recovering ... treat clouding of the lens in the eye). Diclofenac ophthalmic solution is also used to temporarily relieve ...

  15. High and ultra-high resolution metabolite mapping of the human brain using 1H FID MRSI at 9.4T.

    Science.gov (United States)

    Nassirpour, Sahar; Chang, Paul; Henning, Anke

    2018-03-01

    Magnetic resonance spectroscopic imaging (MRSI) is a promising technique for mapping the spatial distribution of multiple metabolites in the human brain. These metabolite maps can be used as a diagnostic tool to gain insight into several biochemical processes and diseases in the brain. In comparison to lower field strengths, MRSI at ultra-high field strengths benefits from a higher signal to noise ratio (SNR) as well as higher chemical shift dispersion, and hence spectral resolution. This study combines the benefits of an ultra-high field magnet with the advantages of an ultra-short TE and TR single-slice FID-MRSI sequence (such as negligible J-evolution and loss of SNR due to T 2 relaxation effects) and presents the first metabolite maps acquired at 9.4T in the healthy human brain at both high (voxel size of 97.6µL) and ultra-high (voxel size of 24.4µL) spatial resolutions in a scan time of 11 and 46min respectively. In comparison to lower field strengths, more anatomically-detailed maps with higher SNR from a larger number of metabolites are shown. A total of 12 metabolites including glutamate (Glu), glutamine (Gln), N-acetyl-aspartyl-glutamate (NAAG), Gamma-aminobutyric acid (GABA) and glutathione (GSH) are reliably mapped. Comprehensive description of the methodology behind these maps is provided. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Ultra-High Resolution Optical Coherence Tomography Imaging of Unilateral Drusen in a 31 Year Old Woman.

    Science.gov (United States)

    de Carlo, Talisa E; Adhi, Mehreen; Lu, Chen D; Duker, Jay S; Fujimoto, James G; Waheed, Nadia K

    We report a case of widespread unilateral drusen in a healthy 31 year old Caucasian woman using multi-modal imaging including ultra-high resolution optical coherence tomography (UHR-OCT). Dilated fundus exam showed multiple drusen-like lesions in the posterior pole without heme or fluid. Fundus auto fluorescence demonstrated hyperautofluorescent at the deposits. Fluorescein angiography revealed mild hyperfluorescence and staining of the lesions. Spectral-domain optical coherence tomography (SD-OCT) OS showed accumulations in the temporal macula at Bruch's membrane. UHR-OCT provided improved axial resolution compared to the standard 5 μm on the commercial SD-OCT and confirmed the presence of deposits in Bruch's membrane, consistent with drusen. The retinal layers were draped over the excrescences but did not show any disruption.

  17. Basics of Sterile Compounding: Ophthalmic Preparations, Part 1: Ophthalmic Solutions.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    Ophthalmic preparations are used to treat allergies, bacterial and viral infections, glaucoma, and numerous other eye conditions. When the eye's natural defensive mechanisms are compromised or overcome, an ophthalmic preparation, in a solution, suspension, or ointment form, may be indicated, with solutions being the most common form used to deliver a drug to the eye. This article provides a general discussion on ophthalmic preparations and specifically discusses the preparation of solutions. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  18. The Role of Ultrahigh Resolution Fourier Transform Mass Spectrometry (FT-MS) in Astrobiology-Related Research: Analysis of Meteorites and Tholins.

    Science.gov (United States)

    Somogyi, Árpád; Thissen, Roland; Orthous-Daunay, Francois-Régis; Vuitton, Véronique

    2016-03-24

    It is an important but also a challenging analytical problem to understand the chemical composition and structure of prebiotic organic matter that is present in extraterrestrial materials. Its formation, evolution and content in the building blocks ("seeds") for more complex molecules, such as proteins and DNA, are key questions in the field of exobiology. Ultrahigh resolution mass spectrometry is one of the best analytical techniques that can be applied because it provides reliable information on the chemical composition and structure of individual components of complex organic mixtures. Prebiotic organic material is delivered to Earth by meteorites or generated in laboratories in simulation (model) experiments that mimic space or atmospheric conditions. Recent representative examples for ultrahigh resolution mass spectrometry studies using Fourier-transform (FT) mass spectrometers such as Orbitrap and ion cyclotron resonance (ICR) mass spectrometers are shown and discussed in the present article, including: (i) the analysis of organic matter of meteorites; (ii) modeling atmospheric processes in ICR cells; and (iii) the structural analysis of laboratory made tholins that might be present in the atmosphere and surface of Saturn's largest moon, Titan.

  19. Ultra-high resolution water window x ray microscope optics design and analysis

    Science.gov (United States)

    Shealy, David L.; Wang, C.

    1993-01-01

    This project has been focused on the design and analysis of an ultra-high resolution water window soft-x-ray microscope. These activities have been accomplished by completing two tasks contained in the statement of work of this contract. The new results from this work confirm: (1) that in order to achieve resolutions greater than three times the wavelength of the incident radiation, it will be necessary to use spherical mirror surfaces and to use graded multilayer coatings on the secondary in order to accommodate the large variations of the angle of incidence over the secondary when operating the microscope at numerical apertures of 0.35 or greater; (2) that surface contour errors will have a significant effect on the optical performance of the microscope and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror; and (3) that tolerance analysis of the spherical Schwarzschild microscope has been shown that the water window operations will require 2-3 times tighter tolerances to achieve a similar performance of operations with 130 A radiation. These results have been included in a manuscript included in the appendix.

  20. Wavy Architecture Thin-Film Transistor for Ultrahigh Resolution Flexible Displays

    KAUST Repository

    Hanna, Amir Nabil; Kutbee, Arwa Talal; Subedi, Ram Chandra; Ooi, Boon S.; Hussain, Muhammad Mustafa

    2017-01-01

    A novel wavy-shaped thin-film-transistor (TFT) architecture, capable of achieving 70% higher drive current per unit chip area when compared with planar conventional TFT architectures, is reported for flexible display application. The transistor, due to its atypical architecture, does not alter the turn-on voltage or the OFF current values, leading to higher performance without compromising static power consumption. The concept behind this architecture is expanding the transistor's width vertically through grooved trenches in a structural layer deposited on a flexible substrate. Operation of zinc oxide (ZnO)-based TFTs is shown down to a bending radius of 5 mm with no degradation in the electrical performance or cracks in the gate stack. Finally, flexible low-power LEDs driven by the respective currents of the novel wavy, and conventional coplanar architectures are demonstrated, where the novel architecture is able to drive the LED at 2 × the output power, 3 versus 1.5 mW, which demonstrates the potential use for ultrahigh resolution displays in an area efficient manner.

  1. Wavy Architecture Thin-Film Transistor for Ultrahigh Resolution Flexible Displays

    KAUST Repository

    Hanna, Amir Nabil

    2017-11-13

    A novel wavy-shaped thin-film-transistor (TFT) architecture, capable of achieving 70% higher drive current per unit chip area when compared with planar conventional TFT architectures, is reported for flexible display application. The transistor, due to its atypical architecture, does not alter the turn-on voltage or the OFF current values, leading to higher performance without compromising static power consumption. The concept behind this architecture is expanding the transistor\\'s width vertically through grooved trenches in a structural layer deposited on a flexible substrate. Operation of zinc oxide (ZnO)-based TFTs is shown down to a bending radius of 5 mm with no degradation in the electrical performance or cracks in the gate stack. Finally, flexible low-power LEDs driven by the respective currents of the novel wavy, and conventional coplanar architectures are demonstrated, where the novel architecture is able to drive the LED at 2 × the output power, 3 versus 1.5 mW, which demonstrates the potential use for ultrahigh resolution displays in an area efficient manner.

  2. Toward an ultra-high resolution community climate system model for the BlueGene platform

    International Nuclear Information System (INIS)

    Dennis, John M; Jacob, Robert; Vertenstein, Mariana; Craig, Tony; Loy, Raymond

    2007-01-01

    Global climate models need to simulate several small, regional-scale processes which affect the global circulation in order to accurately simulate the climate. This is particularly important in the ocean where small scale features such as oceanic eddies are currently represented with adhoc parameterizations. There is also a need for higher resolution to provide climate predictions at small, regional scales. New high-performance computing platforms such as the IBM BlueGene can provide the necessary computational power to perform ultra-high resolution climate model integrations. We have begun to investigate the scaling of the individual components of the Community Climate System Model to prepare it for integrations on BlueGene and similar platforms. Our investigations show that it is possible to successfully utilize O(32K) processors. We describe the scalability of five models: the Parallel Ocean Program (POP), the Community Ice CodE (CICE), the Community Land Model (CLM), and the new CCSM sequential coupler (CPL7) which are components of the next generation Community Climate System Model (CCSM); as well as the High-Order Method Modeling Environment (HOMME) which is a dynamical core currently being evaluated within the Community Atmospheric Model. For our studies we concentrate on 1/10 0 resolution for CICE, POP, and CLM models and 1/4 0 resolution for HOMME. The ability to simulate high resolutions on the massively parallel petascale systems that will dominate high-performance computing for the foreseeable future is essential to the advancement of climate science

  3. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  4. Ultrahigh-resolution imaging of the human brain with phase-cycled balanced steady-state free precession at 7 T.

    Science.gov (United States)

    Zeineh, Michael M; Parekh, Mansi B; Zaharchuk, Greg; Su, Jason H; Rosenberg, Jarrett; Fischbein, Nancy J; Rutt, Brian K

    2014-05-01

    The objectives of this study were to acquire ultra-high resolution images of the brain using balanced steady-state free precession (bSSFP) at 7 T and to identify the potential utility of this sequence. Eight volunteers participated in this study after providing informed consent. Each volunteer was scanned with 8 phase cycles of bSSFP at 0.4-mm isotropic resolution using 0.5 number of excitations and 2-dimensional parallel acceleration of 1.75 × 1.75. Each phase cycle required 5 minutes of scanning, with pauses between the phase cycles allowing short periods of rest. The individual phase cycles were aligned and then averaged. The same volunteers underwent scanning using 3-dimensional (3D) multiecho gradient recalled echo at 0.8-mm isotropic resolution, 3D Cube T2 at 0.7-mm isotropic resolution, and thin-section coronal oblique T2-weighted fast spin echo at 0.22 × 0.22 × 2.0-mm resolution for comparison. Two neuroradiologists assessed image quality and potential research and clinical utility. The volunteers generally tolerated the scan sessions well, and composite high-resolution bSSFP images were produced for each volunteer. Rater analysis demonstrated that bSSFP had a superior 3D visualization of the microarchitecture of the hippocampus, very good contrast to delineate the borders of the subthalamic nucleus, and relatively good B1 homogeneity throughout. In addition to an excellent visualization of the cerebellum, subtle details of the brain and skull base anatomy were also easier to identify on the bSSFP images, including the line of Gennari, membrane of Liliequist, and cranial nerves. Balanced steady-state free precession had a strong iron contrast similar to or better than the comparison sequences. However, cortical gray-white contrast was significantly better with Cube T2 and T2-weighted fast spin echo. Balanced steady-state free precession can facilitate ultrahigh-resolution imaging of the brain. Although total imaging times are long, the individually short

  5. The Role of Ultrahigh Resolution Fourier Transform Mass Spectrometry (FT-MS in Astrobiology-Related Research: Analysis of Meteorites and Tholins

    Directory of Open Access Journals (Sweden)

    Árpád Somogyi

    2016-03-01

    Full Text Available It is an important but also a challenging analytical problem to understand the chemical composition and structure of prebiotic organic matter that is present in extraterrestrial materials. Its formation, evolution and content in the building blocks (“seeds” for more complex molecules, such as proteins and DNA, are key questions in the field of exobiology. Ultrahigh resolution mass spectrometry is one of the best analytical techniques that can be applied because it provides reliable information on the chemical composition and structure of individual components of complex organic mixtures. Prebiotic organic material is delivered to Earth by meteorites or generated in laboratories in simulation (model experiments that mimic space or atmospheric conditions. Recent representative examples for ultrahigh resolution mass spectrometry studies using Fourier-transform (FT mass spectrometers such as Orbitrap and ion cyclotron resonance (ICR mass spectrometers are shown and discussed in the present article, including: (i the analysis of organic matter of meteorites; (ii modeling atmospheric processes in ICR cells; and (iii the structural analysis of laboratory made tholins that might be present in the atmosphere and surface of Saturn’s largest moon, Titan.

  6. The Role of Ultrahigh Resolution Fourier Transform Mass Spectrometry (FT-MS) in Astrobiology-Related Research: Analysis of Meteorites and Tholins

    Science.gov (United States)

    Somogyi, Árpád; Thissen, Roland; Orthous-Daunay, Francois-Régis; Vuitton, Véronique

    2016-01-01

    It is an important but also a challenging analytical problem to understand the chemical composition and structure of prebiotic organic matter that is present in extraterrestrial materials. Its formation, evolution and content in the building blocks (“seeds”) for more complex molecules, such as proteins and DNA, are key questions in the field of exobiology. Ultrahigh resolution mass spectrometry is one of the best analytical techniques that can be applied because it provides reliable information on the chemical composition and structure of individual components of complex organic mixtures. Prebiotic organic material is delivered to Earth by meteorites or generated in laboratories in simulation (model) experiments that mimic space or atmospheric conditions. Recent representative examples for ultrahigh resolution mass spectrometry studies using Fourier-transform (FT) mass spectrometers such as Orbitrap and ion cyclotron resonance (ICR) mass spectrometers are shown and discussed in the present article, including: (i) the analysis of organic matter of meteorites; (ii) modeling atmospheric processes in ICR cells; and (iii) the structural analysis of laboratory made tholins that might be present in the atmosphere and surface of Saturn’s largest moon, Titan. PMID:27023520

  7. Monte Carlo Simulations of Ultra-High Energy Resolution Gamma Detectors for Nuclear Safeguards

    International Nuclear Information System (INIS)

    Robles, A.; Drury, O.B.; Friedrich, S.

    2009-01-01

    Ultra-high energy resolution superconducting gamma-ray detectors can improve the accuracy of non-destructive analysis for unknown radioactive materials. These detectors offer an order of magnitude improvement in resolution over conventional high purity germanium detectors. The increase in resolution reduces errors from line overlap and allows for the identification of weaker gamma-rays by increasing the magnitude of the peaks above the background. In order to optimize the detector geometry and to understand the spectral response function Geant4, a Monte Carlo simulation package coded in C++, was used to model the detectors. Using a 1 mm 3 Sn absorber and a monochromatic gamma source, different absorber geometries were tested. The simulation was expanded to include the Cu block behind the absorber and four layers of shielding required for detector operation at 0.1 K. The energy spectrum was modeled for an Am-241 and a Cs-137 source, including scattering events in the shielding, and the results were compared to experimental data. For both sources the main spectral features such as the photopeak, the Compton continuum, the escape x-rays and the backscatter peak were identified. Finally, the low energy response of a Pu-239 source was modeled to assess the feasibility of Pu-239 detection in spent fuel. This modeling of superconducting detectors can serve as a guide to optimize the configuration in future spectrometer designs.

  8. Ultrahigh-Resolution Magnetic Resonance in Inhomogeneous Magnetic Fields: Two-Dimensional Long-Lived-Coherence Correlation Spectroscopy

    Science.gov (United States)

    Chinthalapalli, Srinivas; Bornet, Aurélien; Segawa, Takuya F.; Sarkar, Riddhiman; Jannin, Sami; Bodenhausen, Geoffrey

    2012-07-01

    A half-century quest for improving resolution in Nuclear Magnetic Resonance (NMR) and Magnetic Resonance Imaging (MRI) has enabled the study of molecular structures, biological interactions, and fine details of anatomy. This progress largely relied on the advent of sophisticated superconducting magnets that can provide stable and homogeneous fields with temporal and spatial variations below ΔB0/B0LLC-COSY) opens the way to overcome both inhomogeneous and homogeneous broadening, which arise from local variations in static fields and fluctuating dipole-dipole interactions, respectively. LLC-COSY makes it possible to obtain ultrahigh resolution two-dimensional spectra, with linewidths on the order of Δν=0.1 to 1 Hz, even in very inhomogeneous fields (ΔB0/B0>10ppm or 5000 Hz at 9.7 T), and can improve resolution by a factor up to 9 when the homogeneous linewidths are determined by dipole-dipole interactions. The resulting LLC-COSY spectra display chemical shift differences and scalar couplings in two orthogonal dimensions, like in “J spectroscopy.” LLC-COSY does not require any sophisticated gradient switching or frequency-modulated pulses. Applications to in-cell NMR and to magnetic resonance spectroscopy (MRS) of selected volume elements in MRI appear promising, particularly when susceptibility variations tend to preclude high resolution.

  9. 75 FR 54492 - Ophthalmic and Topical Dosage Form New Animal Drugs; Gentamicin and Betamethasone Ophthalmic...

    Science.gov (United States)

    2010-09-08

    ... Ophthalmic Solution AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; technical amendment... acetate ophthalmic solution. This action is being taken to comply with the Federal Food, Drug, and... GENTOCIN DURAFILM (gentamicin sulfate and betamethasone acetate) Ophthalmic Solution, sponsored by Intervet...

  10. 21 CFR 886.4790 - Ophthalmic sponge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic sponge. 886.4790 Section 886.4790 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4790 Ophthalmic sponge. (a) Identification. An ophthalmic sponge is a device that is an absorbant sponge, pad, or spear made of folded gauze, cotton...

  11. The Israeli EA-FEL Upgrade Towards Long Pulse Operation for Ultra-High Resolution Single Pulse Coherent Spectroscopy

    CERN Document Server

    Gover, A; Kanter, M; Kapilevich, B; Litvak, B; Peleg, S; Socol, Y; Volshonok, M

    2005-01-01

    The Israeli Electrostatic Accelerator FEL (EA-FEL) is now being upgraded towards long pulse (1005s) operation and ultra-high resolution (10(-6)) single pulse coherent spectroscopy. We present quantitative estimations regarding the applications of controlled radiation chirp for spectroscopic applications with pulse-time Fourier Transform limited spectral resolution. Additionally, we describe a novel extraction-efficiency-improving scheme based on increase of accelerating voltage (boosting) after saturation is achieved. The efficiency of the proposed scheme is confirmed by theoretical and numerical calculations. The latter are performed using software, based on 3D space-frequency domain model. The presentation provides an overview of the upgrade status: the high-voltage terminal is being reconfigured to accept the accelerating voltage boost system; a new broad band low-loss resonator is being manufactured; multi-stage depressed collector is assembled.

  12. 21 CFR 886.4390 - Ophthalmic laser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic laser. 886.4390 Section 886.4390 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4390 Ophthalmic laser. (a) Identification. An ophthalmic laser is an AC-powered device intended to coagulate or cut tissue of the eye, orbit, or surrounding skin...

  13. Toward an ultra-high resolution community climate system model for the BlueGene platform

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, John M [Computer Science Section, National Center for Atmospheric Research, Boulder, CO (United States); Jacob, Robert [Mathematics and Computer Science Division, Argonne National Laboratory, Argonne, IL (United States); Vertenstein, Mariana [Climate and Global Dynamics Division, National Center for Atmospheric Research, Boulder, CO (United States); Craig, Tony [Climate and Global Dynamics Division, National Center for Atmospheric Research, Boulder, CO (United States); Loy, Raymond [Mathematics and Computer Science Division, Argonne National Laboratory, Argonne, IL (United States)

    2007-07-15

    Global climate models need to simulate several small, regional-scale processes which affect the global circulation in order to accurately simulate the climate. This is particularly important in the ocean where small scale features such as oceanic eddies are currently represented with adhoc parameterizations. There is also a need for higher resolution to provide climate predictions at small, regional scales. New high-performance computing platforms such as the IBM BlueGene can provide the necessary computational power to perform ultra-high resolution climate model integrations. We have begun to investigate the scaling of the individual components of the Community Climate System Model to prepare it for integrations on BlueGene and similar platforms. Our investigations show that it is possible to successfully utilize O(32K) processors. We describe the scalability of five models: the Parallel Ocean Program (POP), the Community Ice CodE (CICE), the Community Land Model (CLM), and the new CCSM sequential coupler (CPL7) which are components of the next generation Community Climate System Model (CCSM); as well as the High-Order Method Modeling Environment (HOMME) which is a dynamical core currently being evaluated within the Community Atmospheric Model. For our studies we concentrate on 1/10{sup 0} resolution for CICE, POP, and CLM models and 1/4{sup 0} resolution for HOMME. The ability to simulate high resolutions on the massively parallel petascale systems that will dominate high-performance computing for the foreseeable future is essential to the advancement of climate science.

  14. Ultra-low noise supercontinuum source for ultra-high resolution optical coherence tomography at 1300 nm

    Science.gov (United States)

    Gonzalo, I. B.; Maria, M.; Engelsholm, R. D.; Feuchter, T.; Leick, L.; Moselund, P. M.; Podoleanu, A.; Bang, O.

    2018-02-01

    Supercontinuum (SC) sources are of great interest for many applications due to their ultra-broad optical bandwidth, good beam quality and high power spectral density [1]. In particular, the high average power over large bandwidths makes SC light sources excellent candidates for ultra-high resolution optical coherence tomography (UHR-OCT) [2-5]. However, conventional SC sources suffer from high pulse-to-pulse intensity fluctuations as a result of the noise-sensitive nonlinear effects involved in the SC generation process [6-9]. This intensity noise from the SC source can limit the performance of OCT, resulting in a reduced signal-to-noise ratio (SNR) [10-12]. Much work has been done to reduce the noise of the SC sources for instance with fiber tapers [7,8] or increasing the repetition rate of the pump laser for averaging in the spectrometer [10,12]. An alternative approach is to use all-normal dispersion (ANDi) fibers [13,14] to generate SC light from well-known coherent nonlinear processes [15-17]. In fact, reduction of SC noise using ANDi fibers compared to anomalous dispersion SC pumped by sub-picosecond pulses has been recently demonstrated [18], but a cladding mode was used to stabilize the ANDi SC. In this work, we characterize the noise performance of a femtosecond pumped ANDi based SC and a commercial SC source in an UHR-OCT system at 1300 nm. We show that the ANDi based SC presents exceptional noise properties compared to a commercial source. An improvement of 5 dB in SNR is measured in the UHR-OCT system, and the noise behavior resembles that of a superluminiscent diode. This preliminary study is a step forward towards development of an ultra-low noise SC source at 1300 nm for ultra-high resolution OCT.

  15. Band-selective excited ultrahigh resolution PSYCHE-TOCSY: fast screening of organic molecules and complex mixtures.

    Science.gov (United States)

    Kakita, Veera Mohana Rao; Vemulapalli, Sahithya Phani Babu; Bharatam, Jagadeesh

    2016-04-01

    Precise assignments of (1) H atomic sites and establishment of their through-bond COSY or TOCSY connectivity are crucial for molecular structural characterization by using (1) H NMR spectroscopy. However, this exercise is often hampered by signal overlap, primarily because of (1) H-(1) H scalar coupling multiplets, even at typical high magnetic fields. The recent developments in homodecoupling strategies for effectively suppressing the coupling multiplets into nice singlets (pure-shift), particularly, Morris's advanced broadband pure-shift yielded by chirp excitation (PSYCHE) decoupling and ultrahigh resolution PSYCHE-TOCSY schemes, have shown new possibilities for unambiguous structural elucidation of complex organic molecules. The superior broadband PSYCHE-TOCSY exhibits enhanced performance over the earlier TOCSY methods, which however warrants prolonged experimental times due to the requirement of large number of dwell increments along the indirect dimension. Herein, we present fast and band-selective analog of the broadband PSYCHE-TOCSY, which is useful for analyzing complex organic molecules that exhibit characteristic yet crowded spectral regions. The simple pulse scheme relies on band-selective excitation (BSE) followed by PSYCHE homodecoupling in the indirect dimension. The BSE-PSYCHE-TOCSY has been exemplified for Estradiol and a complex carbohydrate mixture comprised of six constituents of closely comparable molecular weights. The experimental times are greatly reduced viz., ~20 fold for Estradiol and ~10 fold for carbohydrate mixture, with respect to the broadband PSYCHE-TOCSY. Furthermore, unlike the earlier homonuclear band-selective decoupling, the BSE-PSYCHE-decoupling provides fully decoupled pure-shift spectra for all the individual chemical sites within the excited band. The BSE-PSYCHE-TOCSY is expected to have significant potential for quick screening of complex organic molecules and mixtures at ultrahigh resolution. Copyright © 2015 John Wiley

  16. Superior ophthalmic vein enlargement and increased muscle index in dysthyroid optic neuropathy.

    Science.gov (United States)

    Lima, Breno da Rocha; Perry, Julian D

    2013-01-01

    To compare superior ophthalmic vein diameter and extraocular muscle index in patients with thyroid eye disease with or without optic neuropathy. High-resolution CT scan images of 40 orbits of 20 patients with history of thyroid eye disease (with or without optic neuropathy), who underwent orbital decompression surgery from January 2007 to November 2009, were retrospectively reviewed. Superior ophthalmic vein diameter was measured in coronal and axial planes. Extraocular muscle index was calculated according to the method proposed by Barrett et al. The clinical diagnosis of optic neuropathy was based on characteristic signs that included afferent pupillary defect, decreased visual acuity, visual field defects, and dyschromatopsia. Orbits were divided in 2 groups based on presence or absence of optic neuropathy. Superior ophthalmic vein diameter was significantly higher in orbits with concomitant optic neuropathy (mean 2.4 ± 0.4mm, p optic neuropathy (mean 57.9% ± 5.7%, p = 0.0002). Muscle index greater than 50% was present in all patients with dysthyroid optic neuropathy. This study suggests that patients with thyroid eye disease with enlarged superior ophthalmic vein and increased extraocular muscle index are more likely to have concomitant optic neuropathy.

  17. Ultra-high field MRI: Advancing systems neuroscience towards mesoscopic human brain function

    NARCIS (Netherlands)

    Dumoulin, Serge O; Fracasso, A.; Van der Zwaag, W.; Siero, Jeroen C W; Petridou, Natalia

    2018-01-01

    Human MRI scanners at ultra-high magnetic field strengths of 7 T and higher are increasingly available to the neuroscience community. A key advantage brought by ultra-high field MRI is the possibility to increase the spatial resolution at which data is acquired, with little reduction in image

  18. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  19. A computational atlas of the hippocampal formation using ex vivo, ultra-high resolution MRI: Application to adaptive segmentation of in vivo MRI

    DEFF Research Database (Denmark)

    Iglesias, Juan Eugenio; Augustinack, Jean C.; Nguyen, Khoa

    2015-01-01

    level using ultra-high resolution, ex vivo MRI. Fifteen autopsy samples were scanned at 0.13 mm isotropic resolution (on average) using customized hardware. The images were manually segmented into 13 different hippocampal substructures using a protocol specifically designed for this study; precise...... datasets with different types of MRI contrast. The results show that the atlas and companion segmentation method: 1) can segment T1 and T2 images, as well as their combination, 2) replicate findings on mild cognitive impairment based on high-resolution T2 data, and 3) can discriminate between Alzheimer......'s disease subjects and elderly controls with 88% accuracy in standard resolution (1 mm) T1 data, significantly outperforming the atlas in FreeSurfer version 5.3 (86% accuracy) and classification based on whole hippocampal volume (82% accuracy)....

  20. 21 CFR 886.4230 - Ophthalmic knife test drum.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic knife test drum. 886.4230 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4230 Ophthalmic knife test drum. (a) Identification. An ophthalmic knife test drum is a device intended to test the keenness of ophthalmic surgical...

  1. 21 CFR 886.5800 - Ophthalmic bar reader.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar reader. 886.5800 Section 886.5800...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5800 Ophthalmic bar reader. (a) Identification. An ophthalmic bar reader is a device that consists of a magnifying lens intended for use by a...

  2. 21 CFR 886.1650 - Ophthalmic bar prism.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar prism. 886.1650 Section 886.1650...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1650 Ophthalmic bar prism. (a) Identification. An ophthalmic bar prism is a device that is a bar composed of fused prisms of gradually increasing...

  3. 21 CFR 886.4750 - Ophthalmic eye shield.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4750 Ophthalmic eye shield. (a) Identification. An ophthalmic eye shield is a device that consists of a plastic or aluminum eye covering intended to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic eye shield. 886.4750 Section 886.4750...

  4. Ophthalmic Disorders in Adults with Down Syndrome

    Directory of Open Access Journals (Sweden)

    Sharon J. Krinsky-McHale

    2012-01-01

    Full Text Available A myriad of ophthalmic disorders is associated with the phenotype of Down syndrome including strabismus, cataracts, and refractive errors potentially resulting in significant visual impairment. Ophthalmic sequelae have been extensively studied in children and adolescents with Down syndrome but less often in older adults. In-depth review of medical records of older adults with Down syndrome indicated that ophthalmic disorders were common. Cataracts were the most frequent ophthalmic disorder reported, followed by refractive errors, strabismus, and presbyopia. Severity of intellectual disability was unrelated to the presence of ophthalmic disorders. Also, ophthalmic disorders were associated with lower vision-dependent functional and cognitive abilities, although not to the extent that was expected. The high prevalence of ophthalmic disorders highlights the need for periodic evaluations and individualized treatment plans for adults with Down syndrome, in general, but especially when concerns are identified.

  5. Next-generation technologies for spatial proteomics: Integrating ultra-high speed MALDI-TOF and high mass resolution MALDI FTICR imaging mass spectrometry for protein analysis.

    Science.gov (United States)

    Spraggins, Jeffrey M; Rizzo, David G; Moore, Jessica L; Noto, Michael J; Skaar, Eric P; Caprioli, Richard M

    2016-06-01

    MALDI imaging mass spectrometry is a powerful analytical tool enabling the visualization of biomolecules in tissue. However, there are unique challenges associated with protein imaging experiments including the need for higher spatial resolution capabilities, improved image acquisition rates, and better molecular specificity. Here we demonstrate the capabilities of ultra-high speed MALDI-TOF and high mass resolution MALDI FTICR IMS platforms as they relate to these challenges. High spatial resolution MALDI-TOF protein images of rat brain tissue and cystic fibrosis lung tissue were acquired at image acquisition rates >25 pixels/s. Structures as small as 50 μm were spatially resolved and proteins associated with host immune response were observed in cystic fibrosis lung tissue. Ultra-high speed MALDI-TOF enables unique applications including megapixel molecular imaging as demonstrated for lipid analysis of cystic fibrosis lung tissue. Additionally, imaging experiments using MALDI FTICR IMS were shown to produce data with high mass accuracy (z 5000) for proteins up to ∼20 kDa. Analysis of clear cell renal cell carcinoma using MALDI FTICR IMS identified specific proteins localized to healthy tissue regions, within the tumor, and also in areas of increased vascularization around the tumor. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. On the possibility of time-lapse ultrahigh-resolution optical coherence tomography for bladder cancer grading

    Science.gov (United States)

    Yuan, Zhijia; Chen, Bai; Ren, Hugang; Pan, Yingtian

    2009-09-01

    It has been recently demonstrated that the cellular details of bladder epithelium embedded in speckle noise can be uncovered with time-lapse ultrahigh-resolution optical coherence tomography (TL-uOCT) by proper time-lapse frame averaging that takes advantage of cellular micromotion in fresh biological tissue ex vivo. Here, spectral-domain 3-D TL-uOCT is reported to further improve the image fidelity, and new experimental evidence is presented to differentiate normal and cancerous nuclei of rodent bladder epithelia. Results of animal cancer study reveal that despite a slight overestimation (e.g., cancerous (e.g., high-grade DN''~13 μm) urothelia, which may potentially be very useful for enhancing the diagnosis of nonpapillary bladder cancer. More animal study is being conducted to examine the utility to differentiate hyperplasia, dysplasia, and carcinoma in situ.

  7. Visualization and tissue classification of human breast cancer images using ultrahigh-resolution OCT (Conference Presentation)

    Science.gov (United States)

    Yao, Xinwen; Gan, Yu; Chang, Ernest W.; Hibshoosh, Hanina; Feldman, Sheldon; Hendon, Christine P.

    2017-02-01

    We employed a home-built ultrahigh resolution (UHR) OCT system at 800nm to image human breast cancer sample ex vivo. The system has an axial resolution of 2.72µm and a lateral resolution of 5.52µm with an extended imaging range of 1.78mm. Over 900 UHR OCT volumes were generated on specimens from 23 breast cancer cases. With better spatial resolution, detailed structures in the breast tissue were better defined. Different types of breast cancer as well as healthy breast tissue can be well delineated from the UHR OCT images. To quantitatively evaluate the advantages of UHR OCT imaging of breast cancer, features derived from OCT intensity images were used as inputs to a machine learning model, the relevance vector machine. A trained machine learning model was employed to evaluate the performance of tissue classification based on UHR OCT images for differentiating tissue types in the breast samples, including adipose tissue, healthy stroma and cancerous region. For adipose tissue, grid-based local features were extracted from OCT intensity data, including standard deviation, entropy, and homogeneity. We showed that it was possible to enhance the classification performance on distinguishing fat tissue from non-fat tissue by using the UHR images when compared with the results based on OCT images from a commercial 1300 nm OCT system. For invasive ductal carcinoma (IDC) and normal stroma differentiation, the classification was based on frame-based features that portray signal penetration depth and tissue reflectivity. The confusing matrix indicated a sensitivity of 97.5% and a sensitivity of 77.8%.

  8. Topical ophthalmic NSAIDs: a discussion with focus on nepafenac ophthalmic suspension

    OpenAIRE

    Gaynes, Bruce I; Onyekwuluje, Anne

    2008-01-01

    Bruce I Gaynes1,2, Anne Onyekwuluje11Departments of Ophthalmology and 2Pharmacology, Rush College of Medicine, Chicago, Illinois, USAAbstract: The removal of diclofenac sodium ophthalmic solution as a viable pharmaceutical entity in September 1999 from the US market spurred considerable interest in the general safety and effectiveness of topical ophthalmic NSAIDs for treatment of anterior segment inflammation. In late 1999 the use of topical ocular NSAIDs declined in the US as a result of inc...

  9. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  10. 21 CFR 886.1405 - Ophthalmic trial lens set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens set. 886.1405 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1405 Ophthalmic trial lens set. (a) Identification. An ophthalmic trial lens set is a device that is a set of lenses of various dioptric powers...

  11. 21 CFR 886.3100 - Ophthalmic tantalum clip.

    Science.gov (United States)

    2010-04-01

    ... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...

  12. Ultra-high resolution AMOLED

    Science.gov (United States)

    Wacyk, Ihor; Prache, Olivier; Ghosh, Amal

    2011-06-01

    AMOLED microdisplays continue to show improvement in resolution and optical performance, enhancing their appeal for a broad range of near-eye applications such as night vision, simulation and training, situational awareness, augmented reality, medical imaging, and mobile video entertainment and gaming. eMagin's latest development of an HDTV+ resolution technology integrates an OLED pixel of 3.2 × 9.6 microns in size on a 0.18 micron CMOS backplane to deliver significant new functionality as well as the capability to implement a 1920×1200 microdisplay in a 0.86" diagonal area. In addition to the conventional matrix addressing circuitry, the HDTV+ display includes a very lowpower, low-voltage-differential-signaling (LVDS) serialized interface to minimize cable and connector size as well as electromagnetic emissions (EMI), an on-chip set of look-up-tables for digital gamma correction, and a novel pulsewidth- modulation (PWM) scheme that together with the standard analog control provides a total dimming range of 0.05cd/m2 to 2000cd/m2 in the monochrome version. The PWM function also enables an impulse drive mode of operation that significantly reduces motion artifacts in high speed scene changes. An internal 10-bit DAC ensures that a full 256 gamma-corrected gray levels are available across the entire dimming range, resulting in a measured dynamic range exceeding 20-bits. This device has been successfully tested for operation at frame rates ranging from 30Hz up to 85Hz. This paper describes the operational features and detailed optical and electrical test results for the new AMOLED WUXGA resolution microdisplay.

  13. 21 CFR 524.1982 - Proparacaine hydrochloride ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Proparacaine hydrochloride ophthalmic solution... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1982 Proparacaine hydrochloride ophthalmic solution. (a) Specifications. The drug is...

  14. A comparative study of noise in supercontinuum light sources for ultra-high resolution optical coherence tomography

    DEFF Research Database (Denmark)

    Maria J., Sanjuan-Ferrer,; Bravo Gonzalo, Ivan; Bondu, Magalie

    2017-01-01

    Supercontinuum (SC) light is a well-established technology, which finds applications in several domains ranging from chemistry to material science and imaging systems [1-2]. More specifically, its ultra-wide optical bandwidth and high average power make it an ideal tool for Optical Coherence...... Tomography (OCT). Over the last 5 years, numerous examples have demonstrated its high potential [3-4] in this context. However, SC light sources present pulse-to-pulse intensity variation that can limit the performance of any OCT system [5] by degrading their signal to noise ratio (SNR). To this goal, we...... have studied and compared the noise of several SC light sources and evaluated how their noise properties affect the performance of Ultra-High Resolution OCT (UHR-OCT) at 1300 nm. We have measured several SC light sources with different parameters (pulse length, energy, seed repetition rate, etc.). We...

  15. 21 CFR 524.390b - Chloramphenicol ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Chloramphenicol ophthalmic solution. 524.390b... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.390b Chloramphenicol ophthalmic solution. (a) Specifications. Each milliliter contains 5...

  16. Clinical Performance of an Ultrahigh Resolution Chromosomal Microarray Optimized for Neurodevelopmental Disorders.

    Science.gov (United States)

    Ho, Karen S; Twede, Hope; Vanzo, Rena; Harward, Erin; Hensel, Charles H; Martin, Megan M; Page, Stephanie; Peiffer, Andreas; Mowery-Rushton, Patricia; Serrano, Moises; Wassman, E Robert

    2016-01-01

    Copy number variants (CNVs) as detected by chromosomal microarray analysis (CMA) significantly contribute to the etiology of neurodevelopmental disorders, such as developmental delay (DD), intellectual disability (ID), and autism spectrum disorder (ASD). This study summarizes the results of 3.5 years of CMA testing by a CLIA-certified clinical testing laboratory 5487 patients with neurodevelopmental conditions were clinically evaluated for rare copy number variants using a 2.8-million probe custom CMA optimized for the detection of CNVs associated with neurodevelopmental disorders. We report an overall detection rate of 29.4% in our neurodevelopmental cohort, which rises to nearly 33% when cases with DD/ID and/or MCA only are considered. The detection rate for the ASD cohort is also significant, at 25%. Additionally, we find that detection rate and pathogenic yield of CMA vary significantly depending on the primary indications for testing, the age of the individuals tested, and the specialty of the ordering doctor. We also report a significant difference between the detection rate on the ultrahigh resolution optimized array in comparison to the array from which it originated. This increase in detection can significantly contribute to the efficient and effective medical management of neurodevelopmental conditions in the clinic.

  17. 21 CFR 524.1044a - Gentamicin ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Gentamicin ophthalmic solution. 524.1044a Section... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1044a Gentamicin ophthalmic solution. (a) Specifications. Each milliliter of sterile aqueous...

  18. Evaluation of experimental cartilage lesions with ultrahigh-resolution multi-slice-CT in comparison to histology

    International Nuclear Information System (INIS)

    Stork, A.; Kemper, J.; Begemann, P. G. C.; Habermann, C.R.; Adam, G.; Priemel, M.; Kummer, T.; Amling, M.

    2004-01-01

    Purpose: histologic validation of ultrahigh-resolution multislice (MS)-CT for the evaluation of focal, experimental cartilage lesions with special regard to the subchondral bone. Testing of micro-CT (μCT) as alternative reference standard. Methods: 32 experimental cartilage lesions in bovine patellae were imaged surrounded by air (MS-CT-air) and immersed in a contrast material solution (MS-CT-CM) with MS-CT (collimation 2 x 0,5 mm). After the μCT (8 μm-voxelsite) examination in three specimen and histologic work-up of 29 specimen two radiologist graded the defects on MS-CT images in consensus (subchondral bone involvement yes or no) and results were compared to the results of histomorphometry and μCT. Results: the MS-CT-air and -CM had an accuracy of 94% (30/32) and 88% (28/32), respectively. MS-CT-air led to one false-positive (remaining cartilage: = 0,1 mm) and false-negative result, each. MS-CT-CM showed false-positive results if the remaining cartilage was [de

  19. Communication: an ophthalmic practice issue.

    Science.gov (United States)

    Whitton, S J

    1995-12-01

    In the 1990's communication becomes an ophthalmic practice issue. The present ophthalmic climate of cost containment, downsizing, budget cuts, and lack of appreciation of contributions, results in a low staff morale. Recognition of the effects of job satisfaction and productivity led one group to seek solutions. A communication task force was formed to identify problems and the appropriate interventions.

  20. 21 CFR 886.1415 - Ophthalmic trial lens frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens frame. 886.1415 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1415 Ophthalmic trial lens frame. (a) Identification. An opthalmic trial lens frame is a mechanical device intended to hold trial lenses for vision...

  1. Combining pixel and object based image analysis of ultra-high resolution multibeam bathymetry and backscatter for habitat mapping in shallow marine waters

    Science.gov (United States)

    Ierodiaconou, Daniel; Schimel, Alexandre C. G.; Kennedy, David; Monk, Jacquomo; Gaylard, Grace; Young, Mary; Diesing, Markus; Rattray, Alex

    2018-06-01

    Habitat mapping data are increasingly being recognised for their importance in underpinning marine spatial planning. The ability to collect ultra-high resolution (cm) multibeam echosounder (MBES) data in shallow waters has facilitated understanding of the fine-scale distribution of benthic habitats in these areas that are often prone to human disturbance. Developing quantitative and objective approaches to integrate MBES data with ground observations for predictive modelling is essential for ensuring repeatability and providing confidence measures for habitat mapping products. Whilst supervised classification approaches are becoming more common, users are often faced with a decision whether to implement a pixel based (PB) or an object based (OB) image analysis approach, with often limited understanding of the potential influence of that decision on final map products and relative importance of data inputs to patterns observed. In this study, we apply an ensemble learning approach capable of integrating PB and OB Image Analysis from ultra-high resolution MBES bathymetry and backscatter data for mapping benthic habitats in Refuge Cove, a temperate coastal embayment in south-east Australia. We demonstrate the relative importance of PB and OB seafloor derivatives for the five broad benthic habitats that dominate the site. We found that OB and PB approaches performed well with differences in classification accuracy but not discernible statistically. However, a model incorporating elements of both approaches proved to be significantly more accurate than OB or PB methods alone and demonstrate the benefits of using MBES bathymetry and backscatter combined for class discrimination.

  2. Ultra-high resolution coded wavefront sensor

    KAUST Repository

    Wang, Congli

    2017-06-08

    Wavefront sensors and more general phase retrieval methods have recently attracted a lot of attention in a host of application domains, ranging from astronomy to scientific imaging and microscopy. In this paper, we introduce a new class of sensor, the Coded Wavefront Sensor, which provides high spatio-temporal resolution using a simple masked sensor under white light illumination. Specifically, we demonstrate megapixel spatial resolution and phase accuracy better than 0.1 wavelengths at reconstruction rates of 50 Hz or more, thus opening up many new applications from high-resolution adaptive optics to real-time phase retrieval in microscopy.

  3. Sildenafil dilates ophthalmic artery in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Akeel AMH Zwain

    2013-08-01

    Full Text Available Background: Conflicting reports exist on the effect of sildenafil on ophthalmic artery blood flow; many visual disturbances due to vascular insult were reported with the use of sildenafil in diabetic patients like nonarteritic ischemic optic neuropathy. Objectives: The present work aimed to investigate whether sildenafil modulates ophthalmic artery vasoreactivity in patients with type 2 diabetes mellitus. Literature reports on this aspect are lacking. Methods: A total of 35 male subjects were enrolled in this study, 18 with type 2 diabetes mellitus matched with 17 normal individuals. Ophthalmic artery was insonated through a transorbital window using colored Doppler equipment with transcranial Doppler facility. Ophthalmic artery reactivity was assessed using breath holding/hyperventilation test, before and after giving 50 mg oral sildenafil. Results: It was found that in both normal subjects and diabetic patients, sildenafil increased baseline control of mean flow velocity of ophthalmic artery significantly (p 0.05 after sildenafil, in normal and diabetic groups. There was a significant increase of resistive index of ophthalmic artery flow in diabetic patients compared with that of normal subject (p < 0.05. Sildenafil decreased resistive index of ophthalmic artery flow significantly only in diabetic patients (p < 0.05. Conclusion: Sildenafil increased MFVopa, but had no significant effect on vasoreactivity of ophthalmic artery; sildenafil decreased resistive index only in type 2 diabetic patients.

  4. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5% compared with branded and generic prednisolone acetate ophthalmic suspension (1%

    Directory of Open Access Journals (Sweden)

    Marlowe ZT

    2013-12-01

    Full Text Available Zora T Marlowe, Stephen R DavioPharmaceutical Product Development, Global Pharmaceutical Research and Development, Bausch and Lomb, Inc, Rochester, NY, USAIntroduction: Loteprednol etabonate (LE ophthalmic gel 0.5% (Lotemax® is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte® and a generic prednisolone acetate suspension 1% were used as comparators.Methods: Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing – consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC method and reported as a percentage of the declared (labeled concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity.Results: Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD] percent declared concentration of 102% (1.92% over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively, with mean concentrations for both falling significantly

  5. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5%) compared with branded and generic prednisolone acetate ophthalmic suspension (1%).

    Science.gov (United States)

    Marlowe, Zora T; Davio, Stephen R

    2014-01-01

    Loteprednol etabonate (LE) ophthalmic gel 0.5% (Lotemax®) is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte®) and a generic prednisolone acetate suspension 1% were used as comparators. Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing - consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC) method and reported as a percentage of the declared (labeled) concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity. Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD]) percent declared concentration of 102% (1.92%) over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively), with mean concentrations for both falling significantly below the declared concentration for drops expressed at the beginning of the 2-week dosing regimen and significantly above the declared concentration for drops expressed near the end of the dosing

  6. 21 CFR 524.1200b - Kanamycin ophthalmic aqueous solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Kanamycin ophthalmic aqueous solution. 524.1200b... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1200b Kanamycin ophthalmic aqueous solution. (a) Specifications. The drug, which is in an aqueous...

  7. Alternative methods of ophthalmic treatment in Russia.

    Science.gov (United States)

    Vader, L

    1994-04-01

    Russian ophthalmic nurses and physicians are using alternative methods of treatment to supplement traditional eye care. As acupuncture and iridology become more popular in the United States, ophthalmic nurses need to be more knowledgeable about these treatments and the implications for patients.

  8. Ultra-High Resolution Spectroscopic Remote Sensing: A Microscope on Planetary Atmospheres

    Science.gov (United States)

    Kostiuk, Theodor

    2010-01-01

    Remote sensing of planetary atmospheres is not complete without studies of all levels of the atmosphere, including the dense cloudy- and haze filled troposphere, relatively clear and important stratosphere and the upper atmosphere, which are the first levels to experience the effects of solar radiation. High-resolution spectroscopy can provide valuable information on these regions of the atmosphere. Ultra-high spectral resolution studies can directly measure atmospheric winds, composition, temperature and non-thermal phenomena, which describe the physics and chemistry of the atmosphere. Spectroscopy in the middle to long infrared wavelengths can also probe levels where dust of haze limit measurements at shorter wavelength or can provide ambiguous results on atmospheric species abundances or winds. A spectroscopic technique in the middle infrared wavelengths analogous to a radio receiver. infrared heterodyne spectroscopy [1], will be describe and used to illustrate the detailed study of atmospheric phenomena not readily possible with other methods. The heterodyne spectral resolution with resolving power greater than 1,000.000 measures the true line shapes of emission and absorption lines in planetary atmospheres. The information on the region of line formation is contained in the line shapes. The absolute frequency of the lines can be measured to I part in 100 ,000,000 and can be used to accurately measure the Doppler frequency shift of the lines, directly measuring the line-of-sight velocity of the gas to --Im/s precision (winds). The technical and analytical methods developed and used to measure and analyze infrared heterodyne measurements will be described. Examples of studies on Titan, Venus, Mars, Earth, and Jupiter will be presented. 'These include atmospheric dynamics on slowly rotating bodies (Titan [2] and Venus [3] and temperature, composition and chemistry on Mars 141, Venus and Earth. The discovery and studies of unique atmospheric phenomena will also be

  9. An atomic resolution scanning tunneling microscope that applies external tensile stress and strain in an ultrahigh vacuum

    International Nuclear Information System (INIS)

    Fujita, D; Kitahara, M; Onishi, K; Sagisaka, K

    2008-01-01

    We have developed an ultrahigh vacuum scanning tunneling microscope with an in situ external stress application capability in order to determine the effects of stress and strain on surface atomistic structures. It is necessary to understand these effects because controlling them will be a key technology that will very likely be used in future nanometer-scale fabrication processes. We used our microscope to demonstrate atomic resolution imaging under external tensile stress and strain on the surfaces of wafers of Si(111) and Si(001). We also successfully observed domain redistribution induced by applying uniaxial stress at an elevated temperature on the surface of a wafer of vicinal Si(100). We confirmed that domains for which an applied tensile stress is directed along the dimer bond become less stable and shrink. This suggests that it may be feasible to fabricate single domain surfaces in a process that controls surface stress and strain

  10. A new kind of monitor for ophthalmic operation

    International Nuclear Information System (INIS)

    Li, G; Wang, L L; Wang, Y; Lin, L; Jiang, W; Lu, Stephen C-Y; Besio, Walter G

    2005-01-01

    The integrity of the vision channel is often checked using VEP in order to avoiding damaging important tissue during an ophthalmic operation. But the measurement of before operations has strong side effects, it may damage the eyeball. We will introduce a new kind for monitoring ophthalmic operations in this paper. It uses visual electrical evoked potential to check the integrity of the vision access and it can monitor ophthalmic operations and avoid damaging any tissue, so it ensures the safety of the operation

  11. A new kind of monitor for ophthalmic operation

    Energy Technology Data Exchange (ETDEWEB)

    Li, G [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Wang, L L [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Wang, Y [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Lin, L [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Jiang, W [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Lu, Stephen C-Y [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Besio, Walter G [Biomedical Engineering Program, and Center for Biomedical Engineering and Rehabilitation Science Louisiana Tech. University, LA (United States)

    2005-01-01

    The integrity of the vision channel is often checked using VEP in order to avoiding damaging important tissue during an ophthalmic operation. But the measurement of before operations has strong side effects, it may damage the eyeball. We will introduce a new kind for monitoring ophthalmic operations in this paper. It uses visual electrical evoked potential to check the integrity of the vision access and it can monitor ophthalmic operations and avoid damaging any tissue, so it ensures the safety of the operation.

  12. High resolution separations of charge variants and disulfide isomers of monoclonal antibodies and antibody drug conjugates using ultra-high voltage capillary electrophoresis with high electric field strength.

    Science.gov (United States)

    Henley, W Hampton; He, Yan; Mellors, J Scott; Batz, Nicholas G; Ramsey, J Michael; Jorgenson, James W

    2017-11-10

    Ultra-high voltage capillary electrophoresis with high electric field strength has been applied to the separation of the charge variants, drug conjugates, and disulfide isomers of monoclonal antibodies. Samples composed of many closely related species are difficult to resolve and quantify using traditional analytical instrumentation. High performance instrumentation can often save considerable time and effort otherwise spent on extensive method development. Ideally, the resolution obtained for a given CE buffer system scales with the square root of the applied voltage. Currently available commercial CE instrumentation is limited to an applied voltage of approximately 30kV and a maximum electric field strength of 1kV/cm due to design limitations. The instrumentation described here is capable of safely applying potentials of at least 120kV with electric field strengths over 2000V/cm, potentially doubling the resolution of the best conventional CE buffer/capillary systems while decreasing analysis time in some applications. Separations of these complex mixtures using this new instrumentation demonstrate the potential of ultra-high voltage CE to identify the presence of previously unresolved components and to reduce analysis time for complex mixtures of antibody variants and drug conjugates. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Distinguishing d- and l-aspartic and isoaspartic acids in amyloid β peptides with ultrahigh resolution ion mobility spectrometry.

    Science.gov (United States)

    Zheng, Xueyun; Deng, Liulin; Baker, Erin S; Ibrahim, Yehia M; Petyuk, Vladislav A; Smith, Richard D

    2017-07-11

    While α-linked amino acids in the l-form are exclusively utilized in mammalian protein building, β-linked and d-form amino acids also have important biological roles. Unfortunately, the structural elucidation and separation of these different amino acid types in peptides has been analytically challenging to date due to the numerous isomers present, limiting our knowledge about their existence and biological roles. Here, we utilized an ultrahigh resolution ion mobility spectrometry platform coupled with mass spectrometry (IMS-MS) to separate amyloid β (Aβ) peptides containing l-aspartic acid, d-aspartic acid, l-isoaspartic acid, and d-isoaspartic acid residues which span α- and β-linked amino acids in both d- and l-forms. The results illustrate how IMS-MS could be used to better understand age-related diseases or protein folding disorders resulting from amino acid modifications.

  14. Ultrahigh-frequency surface acoustic wave generation for acoustic charge transport in silicon

    NARCIS (Netherlands)

    Büyükköse, S.; Vratzov, B.; van der Veen, Johan (CTIT); Santos, P.V.; van der Wiel, Wilfred Gerard

    2013-01-01

    We demonstrate piezo-electrical generation of ultrahigh-frequency surface acoustic waves on silicon substrates, using high-resolution UV-based nanoimprint lithography, hydrogen silsequioxane planarization, and metal lift-off. Interdigital transducers were fabricated on a ZnO layer sandwiched between

  15. Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible "3He/10 T cryostat

    International Nuclear Information System (INIS)

    Allwörden, H. von; Ruschmeier, K.; Köhler, A.; Eelbo, T.; Schwarz, A.; Wiesendanger, R.

    2016-01-01

    The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped "3He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001).

  16. Elemental Composition Analysis to Investigate NOx Effects on Secondary Organic Aerosol from α-Pinene Using Ultrahigh Resolution Mass Spectrometry

    Science.gov (United States)

    Lim, H. J.; Park, J. H.; Babar, Z.

    2015-12-01

    Secondary organic aerosol (SOA) accounts for 20-70% of atmospheric fine aerosol. NOx plays crucial roles in SOA formation and consequently affects the composition and yield of SOA. SOA component speciation is incomplete due to its complex composition of polar oxygenated and multifunctional species. In this study, ultrahigh resolution mass spectrometry (UHR MS) was applied to improve the understanding of NOx effects on biogenic SOA formation by identifying the elemental composition of SOA. Additional research aim was to investigate oligomer components that are considered as a driving force for SOA formation and growth. In this study α-pinene SOA from photochemical reaction was examined. SOA formation was performed in the absence and presence of NOx at dry condition (grant funded by the Korea government (MEST) (No. 2011-01350000).

  17. A lateral chromatic aberration correction system for ultrahigh-definition color video camera

    Science.gov (United States)

    Yamashita, Takayuki; Shimamoto, Hiroshi; Funatsu, Ryohei; Mitani, Kohji; Nojiri, Yuji

    2006-02-01

    We have developed color camera for an 8k x 4k-pixel ultrahigh-definition video system, which is called Super Hi- Vision, with a 5x zoom lens and a signal-processing system incorporating a function for real-time lateral chromatic aberration correction. The chromatic aberration of the lens degrades color image resolution. So in order to develop a compact zoom lens consistent with ultrahigh-resolution characteristics, we incorporated a real-time correction function in the signal-processing system. The signal-processing system has eight memory tables to store the correction data at eight focal length points on the blue and red channels. When the focal length data is inputted from the lens control units, the relevant correction data are interpolated from two of eights correction data tables. This system performs geometrical conversion on both channels using this correction data. This paper describes that the correction function can successfully reduce the lateral chromatic aberration, to an amount small enough to ensure the desired image resolution was achieved over the entire range of the lens in real time.

  18. determinants of general anaesthesia for ophthalmic surgery

    African Journals Online (AJOL)

    DR. CHARLES IMARENGIAYE

    1999-08-01

    Objectives: To study the pattern of anaesthesia for ophthalmic procedures in order to improve the scheduling of cases in the ophthalmic operating room. Methods: The surgical register of the operating room from. August 01, 1999 to July 31, 2004 was examined, to document the types of procedure, timing of surgery (elective ...

  19. Ophthalmic gels: Past, present and future.

    Science.gov (United States)

    Al-Kinani, Ali A; Zidan, Ghada; Elsaid, Naba; Seyfoddin, Ali; Alani, Adam W G; Alany, Raid G

    2018-02-15

    Aqueous gels formulated using hydrophilic polymers (hydrogels) along with those based on stimuli responsive polymers (in situ gelling or gel forming systems) continue to attract increasing interest for various eye health-related applications. They allow the incorporation of a variety of ophthalmic pharmaceuticals to achieve therapeutic levels of drugs and bioactives at target ocular sites. The integration of sophisticated drug delivery technologies such as nanotechnology-based ones with intelligent and environment responsive systems can extend current treatment duration to provide more clinically relevant time courses (weeks and months instead of hours and days) which will inevitably reduce dose frequency, increase patient compliance and improve clinical outcomes. Novel applications and design of contact lenses and intracanalicular delivery devices along with the move towards integrating gels into various drug delivery devices like intraocular pumps, injections and implants has the potential to reduce comorbidities caused by glaucoma, corneal keratopathy, cataract, diabetic retinopathies and age-related macular degeneration. This review describes ophthalmic gelling systems with emphasis on mechanism of gel formation and application in ophthalmology. It provides a critical appraisal of the techniques and methods used in the characterization of ophthalmic preformed gels and in situ gelling systems along with a thorough insight into the safety and biocompatibility of these systems. Newly developed ophthalmic gels, hydrogels, preformed gels and in situ gelling systems including the latest in the area of stimuli responsive gels, molecularly imprinted gels, nanogels, 3D printed hydrogels; 3D printed devices comprising ophthalmic gels are covered. Finally, new applications of gels in the production of artificial corneas, corneal wound healing and hydrogel contact lenses are described. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Crystals of DhaA mutants from Rhodococcus rhodochrous NCIMB 13064 diffracted to ultrahigh resolution: crystallization and preliminary diffraction analysis

    International Nuclear Information System (INIS)

    Stsiapanava, Alena; Koudelakova, Tana; Lapkouski, Mikalai; Pavlova, Martina; Damborsky, Jiri; Kuta Smatanova, Ivana

    2008-01-01

    Three mutants of the haloalkane dehalogenase DhaA derived from R. rhodochrous NCIMB 13064 were crystallized and diffracted to ultrahigh resolution. The enzyme DhaA from Rhodococcus rhodochrous NCIMB 13064 belongs to the haloalkane dehalogenases, which catalyze the hydrolysis of haloalkanes to the corresponding alcohols. The haloalkane dehalogenase DhaA and its variants can be used to detoxify the industrial pollutant 1,2,3-trichloropropane (TCP). Three mutants named DhaA04, DhaA14 and DhaA15 were constructed in order to study the importance of tunnels connecting the buried active site with the surrounding solvent to the enzymatic activity. All protein mutants were crystallized using the sitting-drop vapour-diffusion method. The crystals of DhaA04 belonged to the orthorhombic space group P2 1 2 1 2 1 , while the crystals of the other two mutants DhaA14 and DhaA15 belonged to the triclinic space group P1. Native data sets were collected for the DhaA04, DhaA14 and DhaA15 mutants at beamline X11 of EMBL, DESY, Hamburg to the high resolutions of 1.30, 0.95 and 1.15 Å, respectively

  1. Enhanced Isotopic Ratio Outlier Analysis (IROA Peak Detection and Identification with Ultra-High Resolution GC-Orbitrap/MS: Potential Application for Investigation of Model Organism Metabolomes

    Directory of Open Access Journals (Sweden)

    Yunping Qiu

    2018-01-01

    Full Text Available Identifying non-annotated peaks may have a significant impact on the understanding of biological systems. In silico methodologies have focused on ESI LC/MS/MS for identifying non-annotated MS peaks. In this study, we employed in silico methodology to develop an Isotopic Ratio Outlier Analysis (IROA workflow using enhanced mass spectrometric data acquired with the ultra-high resolution GC-Orbitrap/MS to determine the identity of non-annotated metabolites. The higher resolution of the GC-Orbitrap/MS, together with its wide dynamic range, resulted in more IROA peak pairs detected, and increased reliability of chemical formulae generation (CFG. IROA uses two different 13C-enriched carbon sources (randomized 95% 12C and 95% 13C to produce mirror image isotopologue pairs, whose mass difference reveals the carbon chain length (n, which aids in the identification of endogenous metabolites. Accurate m/z, n, and derivatization information are obtained from our GC/MS workflow for unknown metabolite identification, and aids in silico methodologies for identifying isomeric and non-annotated metabolites. We were able to mine more mass spectral information using the same Saccharomyces cerevisiae growth protocol (Qiu et al. Anal. Chem 2016 with the ultra-high resolution GC-Orbitrap/MS, using 10% ammonia in methane as the CI reagent gas. We identified 244 IROA peaks pairs, which significantly increased IROA detection capability compared with our previous report (126 IROA peak pairs using a GC-TOF/MS machine. For 55 selected metabolites identified from matched IROA CI and EI spectra, using the GC-Orbitrap/MS vs. GC-TOF/MS, the average mass deviation for GC-Orbitrap/MS was 1.48 ppm, however, the average mass deviation was 32.2 ppm for the GC-TOF/MS machine. In summary, the higher resolution and wider dynamic range of the GC-Orbitrap/MS enabled more accurate CFG, and the coupling of accurate mass GC/MS IROA methodology with in silico fragmentation has great

  2. Enhanced Isotopic Ratio Outlier Analysis (IROA) Peak Detection and Identification with Ultra-High Resolution GC-Orbitrap/MS: Potential Application for Investigation of Model Organism Metabolomes.

    Science.gov (United States)

    Qiu, Yunping; Moir, Robyn D; Willis, Ian M; Seethapathy, Suresh; Biniakewitz, Robert C; Kurland, Irwin J

    2018-01-18

    Identifying non-annotated peaks may have a significant impact on the understanding of biological systems. In silico methodologies have focused on ESI LC/MS/MS for identifying non-annotated MS peaks. In this study, we employed in silico methodology to develop an Isotopic Ratio Outlier Analysis (IROA) workflow using enhanced mass spectrometric data acquired with the ultra-high resolution GC-Orbitrap/MS to determine the identity of non-annotated metabolites. The higher resolution of the GC-Orbitrap/MS, together with its wide dynamic range, resulted in more IROA peak pairs detected, and increased reliability of chemical formulae generation (CFG). IROA uses two different 13 C-enriched carbon sources (randomized 95% 12 C and 95% 13 C) to produce mirror image isotopologue pairs, whose mass difference reveals the carbon chain length (n), which aids in the identification of endogenous metabolites. Accurate m/z, n, and derivatization information are obtained from our GC/MS workflow for unknown metabolite identification, and aids in silico methodologies for identifying isomeric and non-annotated metabolites. We were able to mine more mass spectral information using the same Saccharomyces cerevisiae growth protocol (Qiu et al. Anal. Chem 2016) with the ultra-high resolution GC-Orbitrap/MS, using 10% ammonia in methane as the CI reagent gas. We identified 244 IROA peaks pairs, which significantly increased IROA detection capability compared with our previous report (126 IROA peak pairs using a GC-TOF/MS machine). For 55 selected metabolites identified from matched IROA CI and EI spectra, using the GC-Orbitrap/MS vs. GC-TOF/MS, the average mass deviation for GC-Orbitrap/MS was 1.48 ppm, however, the average mass deviation was 32.2 ppm for the GC-TOF/MS machine. In summary, the higher resolution and wider dynamic range of the GC-Orbitrap/MS enabled more accurate CFG, and the coupling of accurate mass GC/MS IROA methodology with in silico fragmentation has great potential in

  3. Ophthalmic masquerades of the atherosclerotic carotids

    Directory of Open Access Journals (Sweden)

    Anupriya Arthur

    2014-01-01

    Full Text Available Patients with carotid atherosclerosis can present with ophthalmic symptoms. These symptoms and signs can be due to retinal emboli, hypoperfusion of the retina and choroid, opening up of collateral channels, or chronic hypoperfusion of the globe (ocular ischemic syndrome. These pathological mechanisms can produce many interesting signs and a careful history can bring out important past symptoms pointing toward the carotid as the source of the patient′s presenting symptom. Such patients are at high risk for an ischemic stroke, especially in the subsequent few days following their first acute symptom. It is important for clinicians to be familiar with these ophthalmic symptoms and signs caused by carotid atherosclerosis for making an early diagnosis and to take appropriate measures to prevent a stroke. This review elaborates the clinical features, importance, and implications of various ophthalmic symptoms and signs resulting from atherosclerotic carotid artery disease.

  4. 21 CFR 886.4350 - Manual ophthalmic surgical instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual ophthalmic surgical instrument. 886.4350 Section 886.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suturing needle, lachrymal probe, trabeculotomy probe, cornea-sclera punch, ophthalmic retractor...

  5. Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible {sup 3}He/10 T cryostat

    Energy Technology Data Exchange (ETDEWEB)

    Allwörden, H. von; Ruschmeier, K.; Köhler, A.; Eelbo, T.; Schwarz, A., E-mail: aschwarz@physnet.uni-hamburg.de; Wiesendanger, R. [Department of Physics, University of Hamburg, Jungiusstrasse 11, 20355 Hamburg (Germany)

    2016-07-15

    The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped {sup 3}He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001).

  6. Treatment of neuro-ophthalmic sarcoidosis.

    Science.gov (United States)

    Frohman, Larry P

    2015-03-01

    Because of the rarity of neuro-ophthalmic sarcoidosis, there are no therapeutic guidelines based on evidence-based medicine for this disorder. Review of literature combined with personal experience. Corticosteroids are the preferred initial therapy for neuro-ophthalmic sarcoidosis. If patients cannot tolerate the requisite dose of corticosteroid needed to control their disease, or if corticosteroids fail to adequately control the disease process, the choices of a second agent are based on the consideration of rapidity of clinical response and the safety profile. Although methotrexate and mycophenolate mofetil are the medications that are often selected after corticosteroid failure, more rapidly acting agents that have been used are infliximab and intravenous cyclophosphamide.

  7. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  8. Audit of Referrals to an Ophthalmic Outpatient Clinic of a Tertiary ...

    African Journals Online (AJOL)

    Objectives: To determine the referral pattern and assess the quality and accuracy of referral letters to the ophthalmic outpatient clinic of University of Nigeria Teaching Hospital, Enugu. Methods: This study is a prospective cross-sectional survey of all new ophthalmic referrals to the ophthalmic outpatient clinic at University of ...

  9. Molecular-level evidence provided by ultrahigh resolution mass spectrometry for oil-derived doc in groundwater at Bemidji, Minnesota

    Science.gov (United States)

    Islam, Ananna; Ahmed, Arif; Hur, Manhoi; Thorn, Kevin A.; Kim, Sunghwan

    2016-01-01

    Dissolved organic matter samples extracted from ground water at the USGS Bemidji oil spill site in Minnesota were investigated by ultrahigh resolution mass spectrometry. Principle component analysis (PCA) of the elemental composition assignments of the samples showed that the score plots for the contaminated sites were well separated from those for the uncontaminated sites. Additionally, spectra obtained from the same sampling site 7 and 19 years after the spill were grouped together in the score plot, strongly suggesting a steady state of contamination within the 12 year interval. The double bond equivalence (DBE) of Ox class compounds was broader for the samples from the contaminated sites, because of the complex nature of oil and the consequent formation of compounds with saturated and/or aromatic structures from the oxygenated products of oil. In addition, Ox class compounds with a relatively smaller number of x (x molecular-level signatures presented here can be a fundamental basis for in-depth analysis of oil contamination.

  10. Degree and duration of corneal anesthesia after topical application of 0.4% oxybuprocaine hydrochloride ophthalmic solution in ophthalmically normal dogs.

    Science.gov (United States)

    Douet, Jean-Yves; Michel, Julien; Regnier, Alain

    2013-10-01

    To assess the anesthetic efficacy and local tolerance of topically applied 0.4% oxybuprocaine ophthalmic solution to in dogs and compare its effects with those of 1% tetracaine solution. 34 ophthalmically normal Beagles. Dogs were assigned to 2 groups, and baseline corneal touch threshold (CTT) was measured bilaterally with a Cochet-Bonnet aesthesiometer. Dogs of group 1 (n = 22) received a single drop of 0.4% oxybuprocaine ophthalmic solution in one eye and saline (0.9% NaCl) solution (control treatment) in the contralateral eye. Dogs of group 2 (n = 12) received a single drop of 0.4% oxybuprocaine ophthalmic solution in one eye and 1% tetracaine ophthalmic solution in the contralateral eye. The CTT of each eye was measured 1 and 5 minutes after topical application and then at 5-minute intervals until 75 minutes after topical application. CTT changes over time differed significantly between oxybuprocaine-treated and control eyes. After instillation of oxybuprocaine, maximal corneal anesthesia (CTT = 0) was achieved within 1 minute, and CTT was significantly decreased from 1 to 45 minutes, compared with the baseline value. No significant difference in onset, depth, and duration of corneal anesthesia was found between oxybuprocaine-treated and tetracaine-treated eyes. Conjunctival hyperemia and chemosis were detected more frequently in tetracaine-treated eyes than in oxybuprocaine-treated eyes. Topical application of oxybuprocaine and tetracaine similarly reduced corneal sensitivity in dogs, but oxybuprocaine was less irritating to the conjunctiva than was tetracaine.

  11. Diquafosol ophthalmic solution 3 %: a review of its use in dry eye.

    Science.gov (United States)

    Keating, Gillian M

    2015-05-01

    Diquafosol ophthalmic solution 3 % (Diquas(®)) is a P2Y2 receptor agonist that promotes tear fluid and mucin secretion and is currently approved in Japan and South Korea for the treatment of dry eye. In randomized, double-blind, multicentre trials in patients with dry eye, significantly greater improvements in fluorescein and rose bengal staining scores were seen with diquafosol ophthalmic solution 3 % than with placebo, and diquafosol ophthalmic solution 3 % was noninferior to sodium hyaluronate ophthalmic solution 0.1 % in terms of the improvement in the fluorescein staining score and more effective than sodium hyaluronate ophthalmic solution 0.1 % in terms of the improvement in the rose bengal staining score. The efficacy of diquafosol ophthalmic solution 3 % in the treatment of dry eye was maintained in the longer term, with improvements also seen in subjective dry eye symptoms, and was also shown in a real-world setting. Diquafosol ophthalmic solution 3 % also demonstrated efficacy in various specific dry eye disorders, including aqueous-deficient dry eye, short tear film break-up time dry eye, obstructive meibomian gland dysfunction, dry eye following laser in situ keratomileusis surgery and dry eye following cataract surgery, as well as in contact lens wearers and visual display terminal users. Diquafosol ophthalmic solution 3 % was generally well tolerated in patients with dry eye, with eye irritation the most commonly reported adverse event. In conclusion, diquafosol ophthalmic solution 3 % is a useful option for the treatment of dry eye.

  12. Rate of bacterial eradication by ophthalmic solutions of fourth-generation fluoroquinolones.

    Science.gov (United States)

    Callegan, Michelle C; Novosad, Billy D; Ramadan, Raniyah T; Wiskur, Brandt; Moyer, Andrea L

    2009-04-01

    Antibacterial activity of ophthalmic fourth-generation fluoroquinolones has traditionally been evaluated by comparing only their active ingredients, gatifloxacin and moxifloxacin. However, ophthalmic formulations of fourth-generation fluoroquinolones differ in terms of the inclusion of preservatives. While gatifloxacin ophthalmic solution 0.3% (Zymar; Allergan, Inc., Irvine, CA, USA) contains 0.005% benzalkonium chloride (BAK), moxifloxacin ophthalmic solution 0.5% (Vigamox; Alcon Laboratories, Inc., Fort Worth, TX, USA) is preservative-free. Recent studies have demonstrated that the presence of BAK dramatically affects the antibacterial activity of the ophthalmic formulation of gatifloxacin. This study was designed to compare the kill rates of ophthalmic solutions of fourth-generation fluoroquinolones against isolates of common ocular bacterial pathogens. Approximately 5.6 log(10) colony-forming units (CFU)/mL of Haemophilus influenzae (n=1), Streptococcus pneumoniae (n=1), Staphylococcus aureus (n=2), methicillin-resistant Staphylococcus aureus (MRSA) (n=4), methicillinresistant Staphylococcus epidermidis (MRSE) (n=4), and fluoroquinolone-resistant S. epidermidis (n=1) were incubated with ophthalmic solutions of either gatifloxacin or moxifloxacin. Viable bacteria were quantified at specific time points up to 60 minutes. Gatifloxacin 0.3% completely eradicated H. influenzae and Strep. pneumoniae in 5 minutes, one of two S. aureus isolates in 15 minutes, and the other S. aureus isolate in 60 minutes. Gatifloxacin 0.3% completely killed all MRSA, MRSE, and fluoroquinolone-resistant S. epidermidis isolates in 15 minutes. Moxifloxacin 0.5% completely eradicated Strep. pneumoniae and one of four MRSA isolates in 60 minutes. All other isolates incubated with moxifloxacin 0.5% retained viable bacteria ranging from 1.8 to 4.4 log(10) CFU/mL. The ophthalmic solution of gatifloxacin 0.3% eradicated bacteria that frequently cause postoperative ocular infections

  13. Ultrahigh stability of atomically thin metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Cao, C. R.; Huang, K. Q.; Zhao, N. J.; Sun, Y. T.; Bai, H. Y.; Gu, L., E-mail: l.gu@iphy.ac.cn, E-mail: dzheng@iphy.ac.cn, E-mail: whw@iphy.ac.cn; Zheng, D. N., E-mail: l.gu@iphy.ac.cn, E-mail: dzheng@iphy.ac.cn, E-mail: whw@iphy.ac.cn; Wang, W. H., E-mail: l.gu@iphy.ac.cn, E-mail: dzheng@iphy.ac.cn, E-mail: whw@iphy.ac.cn [Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-07-07

    We report the fabrication and study of thermal stability of atomically thin ZrCu-based metallic glass films. The ultrathin films exhibit striking dynamic properties, ultrahigh thermal stability, and unique crystallization behavior with discrete crystalline nanoparticles sizes. The mechanisms for the remarkable high stability and crystallization behaviors are attributed to the dewetting process of the ultrathin film. We demonstrated a promising avenue for understanding some fundamental issues such as glassy structure, crystallization, deformation, and glass formation through atomic resolution imaging of the two dimensional like metallic glasses.

  14. 76 FR 30176 - Dermatologic and Ophthalmic Drugs Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-05-24

    ... committee will discuss biologics license application (BLA) 125387, aflibercept ophthalmic solution, proposed...] Dermatologic and Ophthalmic Drugs Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration...: Dermatologic and Ophthalmic Drugs Advisory Committee. General Function of the Committee: To provide advice and...

  15. Non-destructive testing of layer-to-layer fusion of a 3D print using ultrahigh resolution optical coherence tomography

    DEFF Research Database (Denmark)

    Israelsen, Niels Møller; Maria, Michael; Feuchter, Thomas

    2017-01-01

    Within the last decade, 3D printing has moved from a costly approach of building mechanical items to the present state-of-the-art phase where access to 3D printers is now common, both in industry and in private places. The plastic printers are the most common type of 3D printers providing prints...... on volume imaging of a 3D printed block made with 100% PLA fill. By employing ultrahigh resolution OCT (UHR-OCT) we show that some parts of the PLA volume reveal highly scattering interfaces which likely correspond to transitions from one layer to another. In doing so, we document that UHR-OCT can act...... as a powerful tool that can be used in detecting fractures between layers stemming from insufficient fusion between printed structure layers. UHR-OCT can therefore serve as an useful assessment method of quality of 3D prints....

  16. Formularity: Software for Automated Formula Assignment of Natural and Other Organic Matter from Ultrahigh-Resolution Mass Spectra.

    Science.gov (United States)

    Tolić, Nikola; Liu, Yina; Liyu, Andrey; Shen, Yufeng; Tfaily, Malak M; Kujawinski, Elizabeth B; Longnecker, Krista; Kuo, Li-Jung; Robinson, Errol W; Paša-Tolić, Ljiljana; Hess, Nancy J

    2017-12-05

    Ultrahigh resolution mass spectrometry, such as Fourier transform ion cyclotron resonance mass spectrometry (FT ICR MS), can resolve thousands of molecular ions in complex organic matrices. A Compound Identification Algorithm (CIA) was previously developed for automated elemental formula assignment for natural organic matter (NOM). In this work, we describe software Formularity with a user-friendly interface for CIA function and newly developed search function Isotopic Pattern Algorithm (IPA). While CIA assigns elemental formulas for compounds containing C, H, O, N, S, and P, IPA is capable of assigning formulas for compounds containing other elements. We used halogenated organic compounds (HOC), a chemical class that is ubiquitous in nature as well as anthropogenic systems, as an example to demonstrate the capability of Formularity with IPA. A HOC standard mix was used to evaluate the identification confidence of IPA. Tap water and HOC spike in Suwannee River NOM were used to assess HOC identification in complex environmental samples. Strategies for reconciliation of CIA and IPA assignments were discussed. Software and sample databases with documentation are freely available.

  17. Ultra-high Performance Liquid Chromatography in Steroid Analysis

    OpenAIRE

    Salonen, Fanny

    2017-01-01

    The latest version of liquid chromatography is ultra-high performance (or pressure) chromatography (UHPLC). In the technique, short and narrow-bore columns with particle sizes below 3 µm are used. The extremely high pressure used results in very short analysis times, excellent separation, and good resolution. This makes UHPLC a good choice for steroidal analysis. Steroids are a highly interesting area of study; they can be recognized as biomarkers for several diseases and are a relevant topic...

  18. Mnemonic discrimination relates to perforant path integrity: An ultra-high resolution diffusion tensor imaging study.

    Science.gov (United States)

    Bennett, Ilana J; Stark, Craig E L

    2016-03-01

    Pattern separation describes the orthogonalization of similar inputs into unique, non-overlapping representations. This computational process is thought to serve memory by reducing interference and to be mediated by the dentate gyrus of the hippocampus. Using ultra-high in-plane resolution diffusion tensor imaging (hrDTI) in older adults, we previously demonstrated that integrity of the perforant path, which provides input to the dentate gyrus from entorhinal cortex, was associated with mnemonic discrimination, a behavioral outcome designed to load on pattern separation. The current hrDTI study assessed the specificity of this perforant path integrity-mnemonic discrimination relationship relative to other cognitive constructs (identified using a factor analysis) and white matter tracts (hippocampal cingulum, fornix, corpus callosum) in 112 healthy adults (20-87 years). Results revealed age-related declines in integrity of the perforant path and other medial temporal lobe (MTL) tracts (hippocampal cingulum, fornix). Controlling for global effects of brain aging, perforant path integrity related only to the factor that captured mnemonic discrimination performance. Comparable integrity-mnemonic discrimination relationships were also observed for the hippocampal cingulum and fornix. Thus, whereas perforant path integrity specifically relates to mnemonic discrimination, mnemonic discrimination may be mediated by a broader MTL network. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Development and Effects of FTY720 Ophthalmic Solution on Corneal Allograft Survival.

    Science.gov (United States)

    Liu, Zhaochuan; Lin, Haotian; Huang, Chulong; Chen, Wan; Xiang, Wu; Geng, Yu; Chen, Weirong

    2015-11-12

    Fingolimod (FTY720), a novel class of sphingosine 1-phosphate receptor modulators, has received special interest among ophthalmologists, particularly given that oral administration of FTY720 has proven to effectively treat corneal graft rejection in animal models. However, no studies have examined the performance of FTY720 as an ophthalmic solution in reducing corneal rejection in high-risk corneal rejection models, and the stability and ocular irritation profile of FTY720 ophthalmic solution are also unknown. Thus, we developed 0.1%, 0.2% and 0.5% FTY720 ophthalmic solutions and evaluated their chemical stabilities under various storage conditions with high- performance liquid chromatography. To investigate the ocular irritancy of the FTY720 ophthalmic solution, New Zealand albino rabbits were subjected to the Draize test. Furthermore, classic, well-established rat allogenic penetrating keratoplasty models were used to investigate the anti-rejection efficacy of the tested FTY720 ophthalmic solutions. We found that the non-irritating 0.5% FTY720 ophthalmic solution could prolong corneal allograft survival in rats with significant efficacy for about one month. Furthermore, no significant concentration changes occurred in any of the types of FTY720 ophthalmic solutions within three months. These results revealed crucial profiles of FTY720 ophthalmic solutions and warrant further investigation and optimization of FTY720 in the anti-rejection therapy after keratoplasty.

  20. Lifitegrast Ophthalmic Solution 5%: A Review in Dry Eye Disease.

    Science.gov (United States)

    Keating, Gillian M

    2017-02-01

    Lifitegrast is a novel small molecule integrin antagonist that blocks the binding of intercellular adhesion molecule 1 (ICAM-1) to lymphocyte function-associated antigen 1 (LFA-1). Lifitegrast ophthalmic solution 5% (Xiidra™) was recently approved in the USA for the treatment of dry eye disease. The efficacy of lifitegrast ophthalmic solution 5% was compared with vehicle in a 12-week phase 2 study and three 12-week phase 3 studies (OPUS-1, OPUS-2 and OPUS-3) in patients with dry eye disease. Taken as a whole, results of these trials support the treatment effect of lifitegrast ophthalmic solution 5% in improving a symptom of dry eye disease (i.e. the change from baseline to day 84 in the eye dryness visual analogue scale score) and a sign of dry eye disease (i.e. the change from baseline to day 84 in the inferior corneal fluorescein staining score). Lifitegrast ophthalmic solution 5% was generally well tolerated. In conclusion, lifitegrast ophthalmic solution 5% provides a new option for the treatment of dry eye disease.

  1. Allergic Contact Dermatitis to Ophthalmic Medications: Relevant Allergens and Alternative Testing Methods.

    Science.gov (United States)

    Grey, Katherine R; Warshaw, Erin M

    Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.

  2. Readability assessment of online ophthalmic patient information.

    Science.gov (United States)

    Edmunds, Matthew R; Barry, Robert J; Denniston, Alastair K

    2013-12-01

    Patients increasingly use the Internet to access information related to their disease, but poor health literacy is known to impact negatively on medical outcomes. Multiple agencies have recommended that patient-oriented literature be written at a fourth- to sixth-grade (9-12 years of age) reading level to assist understanding. The readability of online patient-oriented materials related to ophthalmic diagnoses is not yet known. To assess the readability of online literature specifically for a range of ophthalmic conditions. Body text of the top 10 patient-oriented websites for 16 different ophthalmic diagnoses, covering the full range of ophthalmic subspecialties, was analyzed for readability, source (United Kingdom vs non-United Kingdom, not for profit vs commercial), and appropriateness for sight-impaired readers. Four validated readability formulas were used: Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Fog Index (GFOG). Data were compared with the Mann-Whitney test (for 2 groups) and Kruskal-Wallis test (for more than 2 groups) and correlation was assessed by the Spearman r. None of the 160 webpages had readability scores within published guidelines, with 83% assessed as being of "difficult" readability. Not-for-profit webpages were of significantly greater length than commercial webpages (P = .02) and UK-based webpages had slightly superior readability scores compared with those of non-UK webpages (P = .004 to P readability formula used). Of all webpages evaluated, only 34% included facility to adjust text size to assist visually impaired readers. To our knowledge, this is the first study to assess readability of patient-focused webpages specifically for a range of ophthalmic diagnoses. In keeping with previous studies in other medical conditions, we determined that readability scores were inferior to those recommended, irrespective of the measure used. Although readability is only one

  3. Bilateral IgG4-related ophthalmic disease: a strong indication for systemic imaging.

    Science.gov (United States)

    Wu, Albert; Andrew, Nicholas H; McNab, Alan A; Selva, Dinesh

    2016-10-01

    To investigate whether bilateral or unilateral IgG4-related ophthalmic disease (IgG4-ROD) is associated with extra-ophthalmic IgG4-related disease (IgG4-RD). Twin-centre retrospective observational case series of biopsy-confirmed IgG4-ROD. Clinical and radiology data were reviewed for laterality of IgG4-ROD and presence of extra-ophthalmic disease. The literature was reviewed for case series of IgG4-ROD. 40 IgG4-ROD cases were identified, with median follow-up of 36 months. At diagnosis of IgG4-ROD, all cases were screened for extra-ophthalmic disease with physical examination and blood testing. Systemic imaging was performed in 20 (50%) cases due to clinical suspicion of extra-ophthalmic disease. Of the 21 unilateral IgG4-ROD cases, 3 (14%) had extra-ophthalmic involvement. Of the 19 bilateral cases, 15 (79%) had extra-ophthalmic involvement. Extra-ophthalmic involvement was strongly associated with bilateral IgG4-ROD (pIgG4-ROD is strongly associated with extra-ophthalmic IgG4-RD. We recommend that imaging of the neck, chest, abdomen and pelvis be performed for all bilateral cases. Systemic imaging should also be considered in unilateral cases as a significant proportion of these patients will also have extra-ophthalmic disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Diquafosol ophthalmic solution for dry eye treatment.

    Science.gov (United States)

    Nakamura, Masatsugu; Imanaka, Takahiro; Sakamoto, Asuka

    2012-07-01

    There has been rapid progress in our understanding of dry eye pathogenesis, as well as the development of improved diagnostic clinical tests. Various types of dry eye treatment drugs have been developed. This review summarizes the basic and clinical research carried out in the development of diquafosol for ophthalmic use. Diquafosol is a dinucleotide, purinoreceptor P2Y(2) receptor agonist. Basic pharmacological studies have shown that it acts on P2Y(2) receptors at the ocular surface, to promote tear and mucin secretion via elevated intracellular Ca(2+) concentrations. Diquafosol also improves tear and mucin secretion in experimental dry eye models. Based on the results of laboratory experiments, the authors conducted a series of clinical studies in patients with dry eye disease. Diquafosol was effective in the treatment of dry eye disease at an optimal dose of 3% six times a day. In comparison to commercially available 0.1% sodium hyaluronate ophthalmic solution, 3% diquafosol ophthalmic solution showed non-inferiority in improving corneal fluorescein staining scores and superiority in improving keratoconjunctival Rose Bengal staining scores. Diquafosol ophthalmic solution has a novel mechanism of action that is characterized by its stimulatory effects on tear and mucin secretion. This drug has the potential to be effective in patients with tear film instability and short break-up time type of dry eye, which are essential factors in dry eye pathogenesis.

  5. A new method for characterizing beta-ray ophthalmic applicator sources

    International Nuclear Information System (INIS)

    Sayeg, J.A.; Gregory, R.C.

    1991-01-01

    A technique is described which enables one to obtain detailed dose characteristics of 90Sr beta-ray ophthalmic applicators. A radiochromic radiation detector which is a solid-state solution of hexahydroxyethyl pararosaniline cyanide in a nylon polymer (i.e., thin foil), has been used to determine the surface dose rate and dose distribution of these sources. The detectors are rugged, easily handled, have an equivalent response (optical density per unit absorbed dose) to photons and electrons, and produce high-resolution images. They have been found useful for this application due to the high surface dose rates [0.10-1.0 Gy (H2O)/s] and their low sensitivity (approximately 10(4) Gy for an optical density of 1.0). The foils have been evaluated on a He-Ne scanning laser densitometer with a resolution of 0.3 mum. Comparison with NIST (formerly NBS) extrapolation ionization chamber measurements indicates surface dose-rate agreement within 6%. Spectral dosimetric characteristics are presented and discussed

  6. Comparison of corneal safety and intraocular pressure-lowering effect of tafluprost ophthalmic solution with other prostaglandin ophthalmic solutions.

    Science.gov (United States)

    Kumagami, Takeshi; Wakiyama, Harumi; Kusano, Mao; Kajiyama, Ayano; Miura, Yoko; Uematsu, Masafumi; Yoneda, Ai; Kurihara, Junko; Suzuma, Kiyoshi; Kitaoka, Takashi

    2014-05-01

    The benzalkonium chloride (BAK) content of tafluprost ophthalmic solution (Tapros(®): tafluprost) has been reduced to balance corneal safety and preservative effectiveness (old formulation: 0.01%; new formulation: 0.001%). However, no reports have been published on its clinical effect. Therefore, we conducted a clinical research study to compare the safety of BAK-reduced tafluprost on the ocular surface with other prostaglandin ophthalmic solutions. This clinical study included 28 glaucoma patients (28 eyes) with a treatment history of latanoprost ophthalmic solution (Xalatan(®)) or travoprost ophthalmic solution (Travatan Z(®)), who presented with corneal epithelial disorders. The subjects were switched to BAK-reduced tafluprost, and its effect on the ocular surface was examined after 1 and 2 months of treatment [using fluorescein staining score, hyperemia, tear film breakup time, and intraocular pressure (IOP) lowering]. In all analyzed subjects (N=27), the fluorescein staining score was significantly improved after switching to BAK-reduced tafluprost (P<0.0001). Conversely, the IOP-lowering effect was not notably changed. The subjects switched from latanoprost (n=10) showed significant improvement in fluorescein staining score (P<0.05) as well as in IOP lowering (P<0.01). The subjects switched from travoprost (n=17) also showed significant improvement in fluorescein staining score (P<0.001), but without a significant change in IOP lowering. Tafluprost with reduced BAK has potential as a superior antiglaucoma drug, not only for its IOP-lowering effect, but also for its good corneal safety profile.

  7. Comparison of systemic absorption between ofloxacin ophthalmic in situ gels and ofloxacin conventional ophthalmic solutions administration to rabbit eyes by HPLC-MS/MS.

    Science.gov (United States)

    Li, Jiawei; Zhao, Hainan; Okeke, Chukwunweike Ikechukwu; Li, Lin; Liu, Zhidong; Yin, Zhongpeng; Zhuang, Pengwei; Sun, Jingtong; Wu, Tao; Wang, Meng; Li, Nan; Pi, Jiaxin; Zhang, Qian; Zhang, Rui; Ma, Li; Pang, Xiaochen; Liu, Zhanbiao; Zhang, Li; Fan, Lili

    2013-06-25

    In recent years, many pharmaceutical scientists have focused on developing the in situ gel-forming systems to overcome the poor bioavailability and therapeutic response exhibited by conventional ophthalmic solutions due to rapid pre-corneal elimination of the drug. The present work was to compare the systemic absorptions of ophthalmic ofloxacin in situ gel with the conventional ofloxacin eye drop after topical instillation to rabbit eyes by HPLC-MS/MS method and also determine the relative contribution of the nasal and the conjunctival mucosae to systemic ofloxacin absorption following topical instillation. The systemic AUC, Cmax, Tmax and Ke for ophthalmic in situ gel and ophthalmic solution after ocular instillation were 202.63±118.85 and 202.25±57.74 ng mL(-1) h, 54.22±28.31 and 48.4±25.97 ng mL(-1), 1.08±0.20 and 1.25±0.88 h, 0.0576±0.0207 and 0.0388±0.0248, respectively. And the values for the ratios of the AUC of anterior chamber of rabbit eye to blood plasma, AUCac/AUCpl, for ofloxacin conventional eye drop and in situ gel were 0.25 and 0.52, respectively. Statistic results showed that there was no significant difference in systemic absorption between the test groups and the reference groups (P>0.05) as both formulations have an AUCsa/AUCpl of 0.35. Therefore, the ophthalmic in situ gel may not decrease the drugs systemic absorption when administered in an equivalent dose as ophthalmic solutions into the rabbit eyes. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Medical physics aspects of ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Palani Selvam, T.; Tripathi, U.B.; Bhatt, B.C.

    2004-11-01

    Intraocular melanoma is the most common primary malignancy of the eye. Radiation therapy using ophthalmic plaque has proved successful in the management of various ocular lesions. Although a few centres were using 90 Sr/ 90 Y plaques for shallow turtlours some years ago, eye plaque therapy was not a common practice in India. A revived interest in the use of eye plaque therapy and very high cost of imported sources has led to the development and production of 125 I seed sources by the Radiopharmaceuticals Division, BARC. This report presents a brief description on the clinical, dosimetry and radiation safety aspects of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta ray and 125 I gamma ray eye plaque applicators. This report has been divided in five Sections. Section I presents general introduction of ophthalmic brachytherapy including the structure of a human eye, types of ophthalmic plaques and characteristics of radioisotopes commonly used in such applications. A brief review of sources, applicators and dosimetry of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta and 125 I gamma ophthalmic plaques are given in Section II and Section III, respectively. Section IV contains the single seed dosimetry data of BARC OcuProsta 125 I seed as well as dosimetry data of typical eye plaques loaded with BARC OcuProsta 125 I seed. Quality assurance and radiation safety aspects of these eye applicators are described in Section V. A proforma of the application required to be filled in by the user institution for obtaining regulatory consent to start eye plaque therapy has also been appended to this report. (author)

  9. Ophthalmic Drug Dosage Forms: Characterisation and Research Methods

    OpenAIRE

    Baranowski, Przemysław; Karolewicz, Bożena; Gajda, Maciej; Pluta, Janusz

    2014-01-01

    This paper describes hitherto developed drug forms for topical ocular administration, that is, eye drops, ointments, in situ gels, inserts, multicompartment drug delivery systems, and ophthalmic drug forms with bioadhesive properties. Heretofore, many studies have demonstrated that new and more complex ophthalmic drug forms exhibit advantage over traditional ones and are able to increase the bioavailability of the active substance by, among others, reducing the susceptibility of drug forms to...

  10. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion.

    Science.gov (United States)

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-12-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed cerebral angiography of 7 patients (4 hyaluronic acid [HA] and 3 autologous fat-injected cases) showing ophthalmic artery and its branches occlusion after cosmetic facial filler injections, and underwent intra-arterial thrombolysis. On selective ophthalmic artery angiograms, all fat-injected patients showed a large filling defect on the proximal ophthalmic artery, whereas the HA-injected patients showed occlusion of the distal branches of the ophthalmic artery. Three HA-injected patients revealed diminished distal runoff of the internal maxillary and facial arteries, which clinically corresponded with skin necrosis. However, all fat-injected patients and one HA-injected patient who were immediately treated with subcutaneous hyaluronidase injection showed preserved distal runoff of the internal maxillary and facial arteries and mild skin problems. The size difference between injected materials seems to be associated with different angiographic findings. Autologous fat is more prone to obstruct proximal part of ophthalmic artery, whereas HA obstructs distal branches. In addition, hydrophilic and volume-expansion property of HA might exacerbate blood flow on injected area, which is also related to skin necrosis. Intra-arterial thrombolysis has a limited role in reconstituting blood flow or regaining vision in cosmetic facial filler-associated ophthalmic artery occlusions.

  11. ULTRAHIGH ENERGY COSMIC RAYS: REVIEW OF THE CURRENT SITUATION

    Directory of Open Access Journals (Sweden)

    Todor Stanev

    2013-12-01

    Full Text Available We describe the current situation of the data on the highest energy particles in the Universe – the ultrahigh energy cosmic rays. The new results in the field come from the Telescope Array experiment in Utah, U.S.A. For this reason we concentrate on the results from these experiments and compare them to the measurements of the other two recent experiments, the High Resolution Fly’sEye and the Southern Auger Observatory.

  12. ANAESTHESIA FOR OPHTHALMIC SURGICAL PROCEDURES

    African Journals Online (AJOL)

    Objective: To review factors influencing the choice of anaesthesia for ophthalmic surgical procedures. ... as risk associated with general anaesthesia (8) they are more .... Wilson ME, Pandey SK, Thakur J. Paediatric cataract blindness in the ...

  13. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  14. Developing a structure-function model for the cryptophyte phycoerythrin 545 using ultrahigh resolution crystallography and ultrafast laser spectroscopy.

    Science.gov (United States)

    Doust, Alexander B; Marai, Christopher N J; Harrop, Stephen J; Wilk, Krystyna E; Curmi, Paul M G; Scholes, Gregory D

    2004-11-12

    Cryptophyte algae differ from cyanobacteria and red algae in the architecture of their photosynthetic light harvesting systems, even though all three are evolutionarily related. Central to cryptophyte light harvesting is the soluble antenna protein phycoerythrin 545 (PE545). The ultrahigh resolution crystal structure of PE545, isolated from a unicellular cryptophyte Rhodomonas CS24, is reported at both 1.1A and 0.97A resolution, revealing details of the conformation and environments of the chromophores. Absorption, emission and polarized steady state spectroscopy (298K, 77K), as well as ultrafast (20fs time resolution) measurements of population dynamics are reported. Coupled with complementary quantum chemical calculations of electronic transitions of the bilins, these enable assignment of spectral absorption characteristics to each chromophore in the structure. Spectral differences between the tetrapyrrole pigments due to chemical differences between bilins, as well as their binding and interaction with the local protein environment are described. Based on these assignments, and considering customized optical properties such as strong coupling, a model for light harvesting by PE545 is developed which explains the fast, directional harvesting of excitation energy. The excitation energy is funnelled from four peripheral pigments (beta158,beta82) into a central chromophore dimer (beta50/beta61) in approximately 1ps. Those chromophores, in turn, transfer the excitation energy to the red absorbing molecules located at the periphery of the complex in approximately 4ps. A final resonance energy transfer step sensitizes just one of the alpha19 bilins on a time scale of 22ps. Furthermore, it is concluded that binding of PE545 to the thylakoid membrane is not essential for efficient energy transfer to the integral membrane chlorophyll a-containing complexes associated with PS-II.

  15. Formularity: Software for Automated Formula Assignment of Natural and Other Organic Matter from Ultrahigh-Resolution Mass Spectra

    Energy Technology Data Exchange (ETDEWEB)

    Tolic, Nikola; Liu, Yina; Liyu, Andrey V.; Shen, Yufeng; Tfaily, Malak M.; Kujawinski, Elizabeth B.; Longnecker, Krista; Kuo, Li-Jung; Robinson, Errol W.; Pasa Tolic, Ljiljana; Hess, Nancy J.

    2017-11-13

    Ultrahigh-resolution mass spectrometry, such as Fourier transform ion-cyclotron resonance mass spectrometry (FT-ICR MS), can resolve thousands of molecular ions in complex organic matrices. A Compound Identification Algorithm (CIA) was previously developed for automated elemental formula assignment for natural organic matter (NOM). In this work we describe a user friendly interface for CIA, titled Formularity, which includes an additional functionality to perform search of formulas based on an Isotopic Pattern Algorithm (IPA). While CIA assigns elemental formulas for compounds containing C, H, O, N, S, and P, IPA is capable of assigning formulas for compounds containing other elements. We used halogenated organic compounds (HOC), a chemical class that is ubiquitous in nature as well as anthropogenic systems, as an example to demonstrate the capability of Formularity with IPA. A HOC standard mix was used to evaluate the identification confidence of IPA. The HOC spike in NOM and tap water were used to assess HOC identification in natural and anthropogenic matrices. Strategies for reconciliation of CIA and IPA assignments are discussed. Software and sample databases with documentation are freely available from the PNNL OMICS software repository https://omics.pnl.gov/software/formularity.

  16. Nontargeted Screening Method for Illegal Additives Based on Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry.

    Science.gov (United States)

    Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang

    2016-09-06

    Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.

  17. Polymyxin B and Trimethoprim Ophthalmic

    Science.gov (United States)

    Polymyxin B and trimethoprim ophthalmic combination is used to treat bacterial infections of the eye including conjunctivitis (pinkeye; infection ... inside and outer parts of the eyelid). Polymyxin B and trimethoprim are in a class of medications ...

  18. Ophthalmic regional blocks: management, challenges, and solutions

    Directory of Open Access Journals (Sweden)

    Palte HD

    2015-08-01

    Full Text Available Howard D Palte Department of Anesthesiology, Perioperative Medicine and Pain Management, Miller School of Medicine, University of Miami, Miami, FL, USA Abstract: In the past decade ophthalmic anesthesia has witnessed a major transformation. The sun has set on the landscape of ophthalmic procedures performed under general anesthesia at in-hospital settings. In its place a new dawn has ushered in the panorama of eye surgeries conducted under regional and topical anesthesia at specialty eye care centers. The impact of the burgeoning geriatric population is that an increasing number of elderly patients will present for eye surgery. In order to accommodate increased patient volumes and simultaneously satisfy administrative initiatives directed at economic frugality, administrators will seek assistance from anesthesia providers in adopting measures that enhance operating room efficiency. The performance of eye blocks in a holding suite meets many of these objectives. Unfortunately, most practicing anesthesiologists resist performing ophthalmic regional blocks because they lack formal training. In future, anesthesiologists will need to block eyes and manage common medical conditions because economic pressures will eliminate routine preoperative testing. This review addresses a variety of topical issues in ophthalmic anesthesia with special emphasis on cannula and needle-based blocks and the new-generation antithrombotic agents. In a constantly evolving arena, the sub-Tenon’s block has gained popularity while the deep angulated intraconal (retrobulbar block has been largely superseded by the shallower extraconal (peribulbar approach. Improvements in surgical technique have also impacted anesthetic practice. For example, phacoemulsification techniques facilitate the conduct of cataract surgery under topical anesthesia, and suture-free vitrectomy ports may cause venous air embolism during air/fluid exchange. Hyaluronidase is a useful adjuvant because it

  19. Besifloxacin ophthalmic suspension 0.6% in patients with bacterial conjunctivitis: A multicenter, prospective, randomized, double-masked, vehicle-controlled, 5-day efficacy and safety study.

    Science.gov (United States)

    Karpecki, Paul; Depaolis, Michael; Hunter, Judy A; White, Eric M; Rigel, Lee; Brunner, Lynne S; Usner, Dale W; Paterno, Michael R; Comstock, Timothy L

    2009-03-01

    Besifloxacin ophthalmic suspension 0.6% is a new topical fluoroquinolone for the treatment of bacterial conjunctivitis. Besifloxacin has potent in vitro activity against a broad spectrum of ocular pathogens, including drug-resistant strains. The primary objective of this study was to compare the clinical and microbiologic efficacy of besifloxacin ophthalmic suspension 0.6% with that of vehicle (the formulation without besifloxacin) in the treatment of bacterial conjunctivitis. This was a multicenter, prospective, randomized, double-masked, vehicle-controlled, parallel-group study in patients with acute bacterial conjunctivitis. Patients received either topical besifloxacin ophthalmic suspension or vehicle administered 3 times daily for 5 days. At study entry and on days 4 and 8 (visits 2 and 3), a clinical assessment of ocular signs and symptoms was performed in both eyes, as well as pinhole visual acuity testing, biomicroscopy, and culture of the infected eye(s). An ophthalmoscopic examination was performed at study entry and on day 8. The primary efficacy outcome measures were clinical resolution and eradication of the baseline bacterial infection on day 8 in culture-confirmed patients. The safety evaluation included adverse events, changes in visual acuity, and biomicroscopy and ophthalmoscopy findings in all patients who received at least 1 dose of active treatment or vehicle. The safety population consisted of 269 patients (mean [SD] age, 34.2 [22.3] years; 60.2% female; 82.5% white) with acute bacterial conjunctivitis. The culture-confirmed intent-to-treat population consisted of 118 patients (60 besifloxacin ophthalmic suspension, 58 vehicle). Significantly more patients receiving besifloxacin ophthalmic suspension than vehicle had clinical resolution of the baseline infection at visit 3 (44/60 [73.3%] vs 25/58 [43.1%], respectively; P suspension compared with vehicle at visit 3 (53/60 [88.3%] vs35/58 [60.3%]; P suspension 0.6% given 3 times daily for 5 days

  20. Post-mortem inference of the human hippocampal connectivity and microstructure using ultra-high field diffusion MRI at 11.7 T.

    Science.gov (United States)

    Beaujoin, Justine; Palomero-Gallagher, Nicola; Boumezbeur, Fawzi; Axer, Markus; Bernard, Jeremy; Poupon, Fabrice; Schmitz, Daniel; Mangin, Jean-François; Poupon, Cyril

    2018-06-01

    The human hippocampus plays a key role in memory management and is one of the first structures affected by Alzheimer's disease. Ultra-high magnetic resonance imaging provides access to its inner structure in vivo. However, gradient limitations on clinical systems hinder access to its inner connectivity and microstructure. A major target of this paper is the demonstration of diffusion MRI potential, using ultra-high field (11.7 T) and strong gradients (750 mT/m), to reveal the extra- and intra-hippocampal connectivity in addition to its microstructure. To this purpose, a multiple-shell diffusion-weighted acquisition protocol was developed to reach an ultra-high spatio-angular resolution with a good signal-to-noise ratio. The MRI data set was analyzed using analytical Q-Ball Imaging, Diffusion Tensor Imaging (DTI), and Neurite Orientation Dispersion and Density Imaging models. High Angular Resolution Diffusion Imaging estimates allowed us to obtain an accurate tractography resolving more complex fiber architecture than DTI models, and subsequently provided a map of the cross-regional connectivity. The neurite density was akin to that found in the histological literature, revealing the three hippocampal layers. Moreover, a gradient of connectivity and neurite density was observed between the anterior and the posterior part of the hippocampus. These results demonstrate that ex vivo ultra-high field/ultra-high gradients diffusion-weighted MRI allows the mapping of the inner connectivity of the human hippocampus, its microstructure, and to accurately reconstruct elements of the polysynaptic intra-hippocampal pathway using fiber tractography techniques at very high spatial/angular resolutions.

  1. 21 CFR 524.1484e - Neomycin sulfate and polymyxin B sulfate ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... ophthalmic solution. 524.1484e Section 524.1484e Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1484e Neomycin sulfate and polymyxin B sulfate ophthalmic solution. (a...

  2. Neuro-ophthalmic and clinical characteristics of brain tumours in a ...

    African Journals Online (AJOL)

    Background: Anecdotally, increasing number of patients are seen at Korle Bu Teaching Hospital (KBTH) with brain tumour. Neuro-ophthalmic symptoms and signs may help in timely diagnosis and intervention. Objective: To evaluate the neuro-ophthalmic and clinical characteristics of brain tumour in patients presenting at a ...

  3. Ultrahigh Resolution 3-Dimensional Imaging, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Southwest Sciences proposes to develop innovative instrumentation for the rapid, 3-dimensional imaging of biological tissues with cellular resolution. Our approach...

  4. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  5. Functional magnetic resonance imaging with ultra-high fields

    International Nuclear Information System (INIS)

    Windischberger, C.; Schoepf, V.; Sladky, R.; Moser, E.; Fischmeister, F.P.S.

    2010-01-01

    Functional magnetic resonance imaging (fMRI) is currently the primary method for non-invasive functional localization in the brain. With the emergence of MR systems with field strengths of 4 Tesla and above, neuronal activation may be studied with unprecedented accuracy. In this article we present different approaches to use the improved sensitivity and specificity for expanding current fMRT resolution limits in space and time based on several 7 Tesla studies. In addition to the challenges that arise with ultra-high magnetic fields possible solutions will be discussed. (orig.) [de

  6. Ultrahigh-speed X-ray imaging of hypervelocity projectiles

    Science.gov (United States)

    Miller, Stuart; Singh, Bipin; Cool, Steven; Entine, Gerald; Campbell, Larry; Bishel, Ron; Rushing, Rick; Nagarkar, Vivek V.

    2011-08-01

    High-speed X-ray imaging is an extremely important modality for healthcare, industrial, military and research applications such as medical computed tomography, non-destructive testing, imaging in-flight projectiles, characterizing exploding ordnance, and analyzing ballistic impacts. We report on the development of a modular, ultrahigh-speed, high-resolution digital X-ray imaging system with large active imaging area and microsecond time resolution, capable of acquiring at a rate of up to 150,000 frames per second. The system is based on a high-resolution, high-efficiency, and fast-decay scintillator screen optically coupled to an ultra-fast image-intensified CCD camera designed for ballistic impact studies and hypervelocity projectile imaging. A specially designed multi-anode, high-fluence X-ray source with 50 ns pulse duration provides a sequence of blur-free images of hypervelocity projectiles traveling at speeds exceeding 8 km/s (18,000 miles/h). This paper will discuss the design, performance, and high frame rate imaging capability of the system.

  7. Design consideration on the synchrotron ultrahigh vacuum system

    International Nuclear Information System (INIS)

    Tsujikawa, H.; Chida, K.; Mizobuchi, A.; Miyahara, A.

    1982-01-01

    Ultrahigh vacuum production for the high-energy heavy-ion accelerator poses special problems concerning beam-gas molecule and beam-wall interactions. In this paper, summary of the TARN ultrahigh vacuum system and design criteria of the synchrotron ultrahigh vacuum system are presented. On-beam pressure of 4 x 10 -11 Torr is achieved in the TARN ultrahigh vacuum system, of which experiences through the construction and the operation are described and discussed. With emphasis on the application of newly developed technique in the fabrication of vacuum chamber and ultrahigh vacuum pump for the synchrotron ultrahigh vacuum system. (author)

  8. A compact sub-Kelvin ultrahigh vacuum scanning tunneling microscope with high energy resolution and high stability.

    Science.gov (United States)

    Zhang, L; Miyamachi, T; Tomanić, T; Dehm, R; Wulfhekel, W

    2011-10-01

    We designed a scanning tunneling microscope working at sub-Kelvin temperatures in ultrahigh vacuum (UHV) in order to study the magnetic properties on the nanoscale. An entirely homebuilt three-stage cryostat is used to cool down the microscope head. The first stage is cooled with liquid nitrogen, the second stage with liquid (4)He. The third stage uses a closed-cycle Joule-Thomson refrigerator of a cooling power of 1 mW. A base temperature of 930 mK at the microscope head was achieved using expansion of (4)He, which can be reduced to ≈400 mK when using (3)He. The cryostat has a low liquid helium consumption of only 38 ml/h and standing times of up to 280 h. The fast cooling down of the samples (3 h) guarantees high sample throughput. Test experiments with a superconducting tip show a high energy resolution of 0.3 meV when performing scanning tunneling spectroscopy. The vertical stability of the tunnel junction is well below 1 pm (peak to peak) and the electric noise floor of tunneling current is about 6fA/√Hz. Atomic resolution with a tunneling current of 1 pA and 1 mV was achieved on Au(111). The lateral drift of the microscope at stable temperature is below 20 pm/h. A superconducting spilt-coil magnet allows to apply an out-of-plane magnetic field of up to 3 T at the sample surface. The flux vortices of a Nb(110) sample were clearly resolved in a map of differential conductance at 1.1 K and a magnetic field of 0.21 T. The setup is designed for in situ preparation of tip and samples under UHV condition.

  9. Precision Near-Field Reconstruction in the Time Domain via Minimum Entropy for Ultra-High Resolution Radar Imaging

    Directory of Open Access Journals (Sweden)

    Jiwoong Yu

    2017-05-01

    Full Text Available Ultra-high resolution (UHR radar imaging is used to analyze the internal structure of objects and to identify and classify their shapes based on ultra-wideband (UWB signals using a vector network analyzer (VNA. However, radar-based imaging is limited by microwave propagation effects, wave scattering, and transmit power, thus the received signals are inevitably weak and noisy. To overcome this problem, the radar may be operated in the near-field. The focusing of UHR radar signals over a close distance requires precise geometry in order to accommodate the spherical waves. In this paper, a geometric estimation and compensation method that is based on the minimum entropy of radar images with sub-centimeter resolution is proposed and implemented. Inverse synthetic aperture radar (ISAR imaging is used because it is applicable to several fields, including medical- and security-related applications, and high quality images of various targets have been produced to verify the proposed method. For ISAR in the near-field, the compensation for the time delay depends on the distance from the center of rotation and the internal RF circuits and cables. Required parameters for the delay compensation algorithm that can be used to minimize the entropy of the radar images are determined so that acceptable results can be achieved. The processing speed can be enhanced by performing the calculations in the time domain without the phase values, which are removed after upsampling. For comparison, the parameters are also estimated by performing random sampling in the data set. Although the reduced data set contained only 5% of the observed angles, the parameter optimization method is shown to operate correctly.

  10. Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the separation of spirostanol saponins.

    Science.gov (United States)

    Zhu, Ling-Ling; Zhao, Yang; Xu, Yong-Wei; Sun, Qing-Long; Sun, Xin-Guang; Kang, Li-Ping; Yan, Ren-Yi; Zhang, Jie; Liu, Chao; Ma, Bai-Ping

    2016-02-20

    Spirostanol saponins are important active components of some herb medicines, and their isolation and purification are crucial for the research and development of traditional Chinese medicines. We aimed to compare the separation of spirostanol saponins by ultra-high performance supercritical fluid chromatography (UHPSFC) and ultra-high performance liquid chromatography (UHPLC). Four groups of spirostanol saponins were separated respectively by UHPSFC and UHPLC. After optimization, UHPSFC was performed with a HSS C18 SB column or a Diol column and with methanol as the co-solvent. A BEH C18 column and mobile phase containing water (with 0.1% formic acid) and acetonitrile were used in UHPLC. We found that UHPSFC could be performed automatically and quickly. It is effective in separating the spirostanol saponins which share the same aglycone and vary in sugar chains, and is very sensitive to the number and the position of hydroxyl groups in aglycones. However, the resolution of spirostanol saponins with different aglycones and the same sugar moiety by UHPSFC was not ideal and could be resolved by UHPLC instead. UHPLC is good at differentiating the variation in aglycones, and is influenced by double bonds in aglycones. Therefore, UHPLC and UHPSFC are complementary in separating spirostanol saponins. Considering the naturally produced spirostanol saponins in herb medicines are different both in aglycones and in sugar chains, a better separation can be achieved by combination of UHPLC and UHPSFC. UHPSFC is a powerful technique for improving the resolution when UHPLC cannot resolve a mixture of spirostanol saponins and vice versa. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. The assessment of visually impaired persons working capacities using electrophysiological and ophthalmic ergonomics methods

    Directory of Open Access Journals (Sweden)

    M. I. Razumovsky

    2014-07-01

    Full Text Available Aim was to analyze working capacities of visually impaired persons by means of complex electrophysiological and ophthalmic ergonomics eye examination.Materials and methods. Standard clinical ophthalmologic examination (visual acuity measurement, refractometry, biomicroscopy, ophthalmoscopy as well as electrophysiological (electrooculography, electrical sensitivity of the eye, critical flicker fusion frequency and ophthalmic ergonomics tests (accommodation measurement, professional testing using automated system «Proftest-1» were performed.Results. Complex electrophysiological and ophthalmic ergonomics tests were performed in 20 visually impaired persons. Their results revealed direct correlation between electrophysiological and ophthalmic ergonomics indices.Conclusion. Working capacities of visually impaired persons can be assessed reliably using complex electrophysiological and ophthalmic ergonomics eye examination only.

  12. The assessment of visually impaired persons working capacities using electrophysiological and ophthalmic ergonomics methods

    Directory of Open Access Journals (Sweden)

    M. I. Razumovsky

    2014-01-01

    Full Text Available Aim was to analyze working capacities of visually impaired persons by means of complex electrophysiological and ophthalmic ergonomics eye examination.Materials and methods. Standard clinical ophthalmologic examination (visual acuity measurement, refractometry, biomicroscopy, ophthalmoscopy as well as electrophysiological (electrooculography, electrical sensitivity of the eye, critical flicker fusion frequency and ophthalmic ergonomics tests (accommodation measurement, professional testing using automated system «Proftest-1» were performed.Results. Complex electrophysiological and ophthalmic ergonomics tests were performed in 20 visually impaired persons. Their results revealed direct correlation between electrophysiological and ophthalmic ergonomics indices.Conclusion. Working capacities of visually impaired persons can be assessed reliably using complex electrophysiological and ophthalmic ergonomics eye examination only.

  13. A computational atlas of the hippocampal formation using ex vivo, ultra-high resolution MRI: Application to adaptive segmentation of in vivo MRI.

    Science.gov (United States)

    Iglesias, Juan Eugenio; Augustinack, Jean C; Nguyen, Khoa; Player, Christopher M; Player, Allison; Wright, Michelle; Roy, Nicole; Frosch, Matthew P; McKee, Ann C; Wald, Lawrence L; Fischl, Bruce; Van Leemput, Koen

    2015-07-15

    Automated analysis of MRI data of the subregions of the hippocampus requires computational atlases built at a higher resolution than those that are typically used in current neuroimaging studies. Here we describe the construction of a statistical atlas of the hippocampal formation at the subregion level using ultra-high resolution, ex vivo MRI. Fifteen autopsy samples were scanned at 0.13 mm isotropic resolution (on average) using customized hardware. The images were manually segmented into 13 different hippocampal substructures using a protocol specifically designed for this study; precise delineations were made possible by the extraordinary resolution of the scans. In addition to the subregions, manual annotations for neighboring structures (e.g., amygdala, cortex) were obtained from a separate dataset of in vivo, T1-weighted MRI scans of the whole brain (1mm resolution). The manual labels from the in vivo and ex vivo data were combined into a single computational atlas of the hippocampal formation with a novel atlas building algorithm based on Bayesian inference. The resulting atlas can be used to automatically segment the hippocampal subregions in structural MRI images, using an algorithm that can analyze multimodal data and adapt to variations in MRI contrast due to differences in acquisition hardware or pulse sequences. The applicability of the atlas, which we are releasing as part of FreeSurfer (version 6.0), is demonstrated with experiments on three different publicly available datasets with different types of MRI contrast. The results show that the atlas and companion segmentation method: 1) can segment T1 and T2 images, as well as their combination, 2) replicate findings on mild cognitive impairment based on high-resolution T2 data, and 3) can discriminate between Alzheimer's disease subjects and elderly controls with 88% accuracy in standard resolution (1mm) T1 data, significantly outperforming the atlas in FreeSurfer version 5.3 (86% accuracy) and

  14. Ophthalmic Drug Dosage Forms: Characterisation and Research Methods

    Directory of Open Access Journals (Sweden)

    Przemysław Baranowski

    2014-01-01

    Full Text Available This paper describes hitherto developed drug forms for topical ocular administration, that is, eye drops, ointments, in situ gels, inserts, multicompartment drug delivery systems, and ophthalmic drug forms with bioadhesive properties. Heretofore, many studies have demonstrated that new and more complex ophthalmic drug forms exhibit advantage over traditional ones and are able to increase the bioavailability of the active substance by, among others, reducing the susceptibility of drug forms to defense mechanisms of the human eye, extending contact time of drug with the cornea, increasing the penetration through the complex anatomical structure of the eye, and providing controlled release of drugs into the eye tissues, which allows reducing the drug application frequency. The rest of the paper describes recommended in vitro and in vivo studies to be performed for various ophthalmic drugs forms in order to assess whether the form is acceptable from the perspective of desired properties and patient’s compliance.

  15. Structural Characterization of Laboratory Made Tholins by IRMPD Action Spectroscopy and Ultrahigh Resolution Mass Spectrometry

    Science.gov (United States)

    Thissen, R.; Somogyi, A.; Vuitton, V.; Bégué, D.; Lemaire, J.; Steinmetz, V.

    2011-10-01

    The complex organic material that is found on the surface and within the haze layer of Titan is attributed to chemistry occurring in its thick N2/CH4 atmosphere. Although several groups are producing in various laboratory setting the socalled tholins which have been investigated by using analytical methods including UV/Vis, fluorescence, IR, and MS1-5, these very complex organic mixtures still hold many unanswered questions, especially related to the potentiality for their prebiotic chemistry. In addition to tholins characterization and analysis, we recently investigated quantitatively the hydrolysis kinetics of tholins in pure and NH3 containing water at different temperatures.7-8 Our groups at UJF (Grenoble) and at U of Arizona (Tucson) have been collaborating on mass spectral analyses of tholins samples for several years.9 Here, we report our most recent results on the structural characterization of tholins by infrared multiphoton dissociation (IRMPD) action spectroscopy10 and ultrahigh resolution MS. IRMPD action spectroscopy is a recently developed technique that uses IR photons of variable wavelengths to activate ions trapped inside an ion trap. When photons are absorbed at a given wavelength, the selected ion fragments and this fragmentation is monitored as a function of wavelength, analog to an absorption spectrum (impossible to record otherwise because of the much reduced density). This technique can, therefore, be used to determine IR spectra of ions in the gas phase, and provides with very acute structural information. IRMPD action spectroscopy is often used to distinguish between structural isomers of isobaric ions. The drawback is that it requests for high power lasers. Only two Free Electron Lasers (FEL) are available in the world and allow to record spectra with reasonable resolution (20-25 cm-1). IRMPD action spectra of selected ions from tholins will be presented and discussed together with observed fragmentation processes that reveal structural

  16. Non-destructive testing of layer-to-layer fusion of a 3D print using ultrahigh resolution optical coherence tomography

    Science.gov (United States)

    Israelsen, Niels M.; Maria, Michael; Feuchter, Thomas; Podoleanu, Adrian; Bang, Ole

    2017-06-01

    Within the last decade, 3D printing has moved from a costly approach of building mechanical items to the present state-of-the-art phase where access to 3D printers is now common, both in industry and in private places. The plastic printers are the most common type of 3D printers providing prints that are light, robust and of lower cost. The robustness of the structure printed is only maintained if each layer printed is properly fused to its previously printed layers. In situations where the printed component has to accomplish a key mechanical role there is a need to characterize its mechanical strength. This may only be revealed by in-depth testing in order to discover unwanted air-gaps in the structure. Optical coherence tomography (OCT) is an in-depth imaging method, that is sensitive to variations in the refractive index and therefore can resolve with high resolution translucid samples. We report on volume imaging of a 3D printed block made with 100% PLA fill. By employing ultrahigh resolution OCT (UHR-OCT) we show that some parts of the PLA volume reveal highly scattering interfaces which likely correspond to transitions from one layer to another. In doing so, we document that UHR-OCT can act as a powerful tool that can be used in detecting fractures between layers stemming from insufficient fusion between printed structure layers. UHR-OCT can therefore serve as an useful assessment method of quality of 3D prints.

  17. Challenges Encountered Using Ophthalmic Anesthetics in Space Medicine

    Science.gov (United States)

    Bayuse, T.; Law, J.; Alexander, D.; Moynihan, S.; LeBlanc, C.; Langford, K.; Magalhaes, L.

    2015-01-01

    On orbit, ophthalmic anesthetics are used for tonometry and off-nominal corneal examinations. Proparacaine has been flown traditionally. However, the manufacturers recently changed its storage requirements from room temperature storage to refrigerated storage to preserve stability and prolong the shelf-life. Since refrigeration on orbit is not readily available and there were stability concerns about flying proparacaine unrefrigerated, tetracaine was selected as an alternative ophthalmic anesthetic in 2013. We will discuss the challenges encountered flying and using these anesthetics on the International Space Station.

  18. The international council of ophthalmology: vision for ophthalmic education in an interdependent world.

    Science.gov (United States)

    Lee, Andrew G; Golnik, Karl C; Tso, Mark O M; Spivey, Bruce; Miller, Kathleen; Gauthier, Tina-Marie

    2012-10-01

    To describe the emerging strategic global perspective of the International Council of Ophthalmology (ICO) efforts in ophthalmic education. A global perspective describing how the development of sophisticated educational tools in tandem with information technology can revolutionize ophthalmic education worldwide. Review of ICO educational tools, resources, and programs that are available to ophthalmic educators across the globe. With the explosive growth of the Internet, the ability to access medical information in the most isolated of locations is now possible. Through specific ICO initiatives, including the ICO curricula, the "Teaching the Teachers" program, and the launching of the new ICO Center for Ophthalmic Educators, the ICO is providing ophthalmic educators across the globe with access to standardized but customizable educational programs and tools to better train ophthalmologists and allied eye care professionals throughout the world. Access to educational tools and strengthening of global learning will help providers meet the goals of VISION 2020 and beyond in eliminating avoidable blindness. It is the intent of the ICO that its programs for ophthalmic educators, including conferences, courses, curricula, and online resources, result in better-trained ophthalmologists and eye care professionals worldwide. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion

    OpenAIRE

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-01-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed...

  20. Ultra-high performance liquid chromatography tandem high-resolution mass spectrometry study of tricyclazole photodegradation products in water.

    Science.gov (United States)

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Bolfi, Bianca; Marengo, Emilio

    2015-06-01

    This paper reports the study of the photodegradation reactions that tricyclazole can naturally undergo, under the action of sunlight, in aqueous solutions of standard tricyclazole and of the commercial BEAM(TM) formulation. The analyses are carried out by ultra-high performance liquid chromatography technique coupled with high-resolution tandem mass spectrometry. Analysis of both tricyclazole and BEAM(TM) water solutions undergone to hydrolysis does not evidence new chromatographic peaks with respect to the not treated solutions. On the contrary, analysis of the same samples subjected to sunlight irradiation shows a decreased intensity of tricyclazole signal and the presence of new chromatographic peaks. Two photodegradation products of tricyclazole have been identified, one of which has been also quantified, being the commercial standard available. The pattern is similar for the solutions of the standard fungicide and of the BEAM(TM) formulation. The results obtained from eco-toxicological tests show that toxicity of tricyclazole standard solutions is greater than that of the irradiated ones, whereas toxicity levels of all the BEAM(TM) solutions investigated (non-irradiated, irradiated, and hydrolyzed) are comparable and lower than those shown by tricyclazole standard solutions. Experiments performed in paddy water solution show that there is no difference in the degradation products formed.

  1. Single photon imaging at ultra-high resolution

    Energy Technology Data Exchange (ETDEWEB)

    Bellazzini, R. [INFN sez. Pisa, Pisa (Italy); Spandre, G. [INFN sez. Pisa, Pisa (Italy)], E-mail: Gloria.Spandre@pi.infn.it; Minuti, M.; Brez, A.; Baldini, L.; Latronico, L.; Omodei, N.; Sgro, C.; Bregeon, J.; Razzano, M.; Pinchera, M. [INFN sez. Pisa, Pisa (Italy); Tremsin, A.; McPhate, J.; Vallerga, J.V.; Siegmund, O. [SSL, Berkeley (United States)

    2008-06-11

    We present a detection system capable of imaging both single photon/positive ion and multiple coincidence photons/positive ions with extremely high spatial resolution. In this detector the photoelectrons excited by the incoming photons are multiplied by microchannel plate(s) (MCP). The process of multiplication is spatially constrained within an MCP pore, which can be as small as 4 {mu}m for commercially available MCPs. An electron cloud originated by a single photoelectron is then encoded by a pixellated custom analog ASIC consisting of 105 K charge sensitive pixels of 50 {mu}m in size arranged on a hexagonal grid. Each pixel registers the charge with an accuracy of <100 electrons rms. Computation of the event centroid from the readout charges results in an accurate event position. A large number of simultaneous photons spatially separated by {approx}0.4 mm can be detected simultaneously allowing multiple coincidence operation for the experiments where a large number of incoming photons/positive ions have to be detected simultaneously. The experimental results prove that the spatial resolution of the readout system itself is {approx}3 {mu}m FWHM enabling detection resolution better than 6 {mu}m for the small pore MCPs. An attractive feature of the detection system is its capability to register the timing of each incoming photon/positive ion (in single photon detection mode) or of the first incoming particle (for the multiple coincidence detection) with an accuracy of {approx}130 ps FWHM. There is also virtually no dark count noise in the detection system making it suitable for low count rate applications.

  2. Investigation of bio-oil produced by hydrothermal liquefaction of food waste using ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Kostyukevich, Yury; Vlaskin, Mikhail; Borisova, Ludmila; Zherebker, Alexander; Perminova, Irina; Kononikhin, Alexey; Popov, Igor; Nikolaev, Eugene

    2018-02-01

    Recent research has revealed that more than 1.3 billion tons of food is wasted globally every year. The disposal of such huge biomass has become a challenge. In the present paper, we report the production of the bio-oil by hydrothermal liquefaction of three classes of food waste: meat, cheese and fruits. The highest yield of the bio-oil was observed for meat (∼60%) and cheese (∼75%), while for fruits, it was considerably low (∼10%). The molecular composition of the obtained bio-oil was investigated using ultrahigh resolution Fourier Transform Ion Cyclotron Resonance mass spectrometry and was found to be similar to that obtained from algae. Several thousand heteroatom compounds (N, N 2 , ON 2 , etc. classes) were reliably identified from each sample. It was found that bio-oils produced from meat and cheese have many compounds (∼90%) with common molecular formulas, while bio-oil produced from fruits differs considerably (∼30% of compounds are unique).

  3. Risk factors of ophthalmic disorders in children with developmental delay

    DEFF Research Database (Denmark)

    Sandfeld, L.N.; Jensen, H.; Skov, L.

    2008-01-01

    PURPOSE: To identify diagnoses that increase the risk of ophthalmic disorders in developmentally delayed children. METHODS: A cross-sectional study of 1126 Danish children with developmental delay (IQ Udgivelsesdato: 2008/12......PURPOSE: To identify diagnoses that increase the risk of ophthalmic disorders in developmentally delayed children. METHODS: A cross-sectional study of 1126 Danish children with developmental delay (IQ Udgivelsesdato: 2008/12...

  4. 21 CFR 524.1662 - Oxytetracycline hydrochloride ophthalmic and topical dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride ophthalmic and topical dosage forms. 524.1662 Section 524.1662 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... DOSAGE FORM NEW ANIMAL DRUGS § 524.1662 Oxytetracycline hydrochloride ophthalmic and topical dosage forms. ...

  5. International Council of Ophthalmology: Refocusing Ophthalmic Education in the Asia-Pacific Region and Beyond.

    Science.gov (United States)

    Golnik, Karl; Mayorga, Eduardo; Spivey, Bruce; Ritch, Robert; Gauthier, Tina-Marie

    2012-01-01

    The International Council of Ophthalmology (ICO) is a global organization with a regional focus. Working in partnership with supranational and ICO member societies, the ICO is building a "World Alliance for Sight" to improve access to the highest-quality eye care worldwide. Designed to preserve and restore vision on an international scale, the ICO initiative, "Refocusing Ophthalmic Education," enhances ophthalmic education of residents, subspecialists, medical students, and allied eye care personnel by redefining the most effective ways to teach and in creating beneficial educational opportunities. The "Teaching the Teachers" program helps ophthalmic educators incorporate more effective methods of training and continuing professional development to meet societal needs, achieved in part through regional courses for residency program directors; symposia, and keynote talks presented by ICO's World Ophthalmology Educational Colloquium, Conferences for Ophthalmic Educators, and ophthalmic surgical competency rubrics. Recognizing that standardized curricula are essential for consistent ophthalmic education, the ICO has developed a curricular framework whereby goals, expectations, knowledge base, competencies, and technical training are delineated. The ICO is defining worldwide models of team training and compiling best practice, which will include training-program accreditation to ensure improvement in the education of ophthalmologists. International Council of Ophthalmology Web-based teaching courses, a Webinar Network, and a technology blog further support information and communication technologies for teaching and learning. At the ICO's Center for Ophthalmic Educators (educators.icoph.org), trainers will find valuable teaching resources in multiple languages as well as ways to share ideas and collaborate with peers and other ophthalmic educators.

  6. Ultra-high temperature direct propulsion

    International Nuclear Information System (INIS)

    Araj, K.J.; Slovik, G.; Powell, J.R.; Ludewig, H.

    1987-01-01

    Potential advantages of ultra-high exhaust temperature (3000 K - 4000 K) direct propulsion nuclear rockets are explored. Modifications to the Particle Bed Reactor (PBR) to achieve these temperatures are described. Benefits of ultra-high temperature propulsion are discussed for two missions - orbit transfer (ΔV = 5546 m/s) and interplanetary exploration (ΔV = 20000 m/s). For such missions ultra-high temperatures appear to be worth the additional complexity. Thrust levels are reduced substantially for a given power level, due to the higher enthalpy caused by partial disassociation of the hydrogen propellant. Though technically challenging, it appears potentially feasible to achieve such ultra high temperatures using the PBR

  7. Spectrally Resolved and Functional Super-resolution Microscopy via Ultrahigh-Throughput Single-Molecule Spectroscopy.

    Science.gov (United States)

    Yan, Rui; Moon, Seonah; Kenny, Samuel J; Xu, Ke

    2018-03-20

    As an elegant integration of the spatial and temporal dimensions of single-molecule fluorescence, single-molecule localization microscopy (SMLM) overcomes the diffraction-limited resolution barrier of optical microscopy by localizing single molecules that stochastically switch between fluorescent and dark states over time. While this type of super-resolution microscopy (SRM) technique readily achieves remarkable spatial resolutions of ∼10 nm, it typically provides no spectral information. Meanwhile, current scanning-based single-location approaches for mapping the positions and spectra of single molecules are limited by low throughput and are difficult to apply to densely labeled (bio)samples. In this Account, we summarize the rationale, design, and results of our recent efforts toward the integration of the spectral dimension of single-molecule fluorescence with SMLM to achieve spectrally resolved SMLM (SR-SMLM) and functional SRM ( f-SRM). By developing a wide-field scheme for spectral measurement and implementing single-molecule fluorescence on-off switching typical of SMLM, we first showed that in densely labeled (bio)samples it is possible to record the fluorescence spectra and positions of millions of single molecules synchronously within minutes, giving rise to ultrahigh-throughput single-molecule spectroscopy and SR-SMLM. This allowed us to first show statistically that for many dyes, single molecules of the same species exhibit near identical emission in fixed cells. This narrow distribution of emission wavelengths, which contrasts markedly with previous results at solid surfaces, allowed us to unambiguously identify single molecules of spectrally similar dyes. Crosstalk-free, multiplexed SRM was thus achieved for four dyes that were merely 10 nm apart in emission spectrum, with the three-dimensional SRM images of all four dyes being automatically aligned within one image channel. The ability to incorporate single-molecule fluorescence measurement with

  8. Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror.

    Science.gov (United States)

    Lu, Chen D; Kraus, Martin F; Potsaid, Benjamin; Liu, Jonathan J; Choi, Woojhon; Jayaraman, Vijaysekhar; Cable, Alex E; Hornegger, Joachim; Duker, Jay S; Fujimoto, James G

    2013-12-20

    We developed an ultrahigh speed, handheld swept source optical coherence tomography (SS-OCT) ophthalmic instrument using a 2D MEMS mirror. A vertical cavity surface-emitting laser (VCSEL) operating at 1060 nm center wavelength yielded a 350 kHz axial scan rate and 10 µm axial resolution in tissue. The long coherence length of the VCSEL enabled a 3.08 mm imaging range with minimal sensitivity roll-off in tissue. Two different designs with identical optical components were tested to evaluate handheld OCT ergonomics. An iris camera aided in alignment of the OCT beam through the pupil and a manual fixation light selected the imaging region on the retina. Volumetric and high definition scans were obtained from 5 undilated normal subjects. Volumetric OCT data was acquired by scanning the 2.4 mm diameter 2D MEMS mirror sinusoidally in the fast direction and linearly in the orthogonal slow direction. A second volumetric sinusoidal scan was obtained in the orthogonal direction and the two volumes were processed with a software algorithm to generate a merged motion-corrected volume. Motion-corrected standard 6 x 6 mm(2) and wide field 10 x 10 mm(2) volumetric OCT data were generated using two volumetric scans, each obtained in 1.4 seconds. High definition 10 mm and 6 mm B-scans were obtained by averaging and registering 25 B-scans obtained over the same position in 0.57 seconds. One of the advantages of volumetric OCT data is the generation of en face OCT images with arbitrary cross sectional B-scans registered to fundus features. This technology should enable screening applications to identify early retinal disease, before irreversible vision impairment or loss occurs. Handheld OCT technology also promises to enable applications in a wide range of settings outside of the traditional ophthalmology or optometry clinics including pediatrics, intraoperative, primary care, developing countries, and military medicine.

  9. Determination of permeability coefficients of ophthalmic drugs through different layers of porcine, rabbit and bovine eyes

    OpenAIRE

    Nagel, Stefan; Guthoff, Rudolf F.; Weitschies, Werner; Seidlitz, Anne; Kristl, Albin; Žakelj, Simon; Loch, Christian

    2015-01-01

    To treat ophthalmic diseases like glaucoma or inflammatory disorders topically applied ophthalmic formulations such as eye drops are usually used. In addition, novel ophthalmic implants releasing drug substances locally into different parts of the eye are available today. In the work presented here, the permeability coefficients of selected drugs (ciprofloxacin hydrochloride, lidocaine hydrochloride, timolol maleate) for ophthalmic tissues were determined using side-by-side diffusion chambers...

  10. Atomic-resolution measurements with a new tunable diode laser-based interferometer

    DEFF Research Database (Denmark)

    Silver, R.M.; Zou, H.; Gonda, S.

    2004-01-01

    is lightweight and is mounted directly on an ultra-high vacuum scanning tunneling microscope capable of atomic resolution. We report the simultaneous acquisition of an atomic resolution image, while the relative lateral displacement of the tip along the sample distance is measured with the new tunable diode...

  11. Comparison of Drug Concentrations in Human Aqueous Humor after the Administration of 0.3% Gatifloxacin Ophthalmic Gel, 0.3% Gatifloxacin and 0.5% Levofloxacin Ophthalmic Solutions.

    Science.gov (United States)

    Ding, Wenting; Ni, Weiling; Chen, Huilian; Yuan, Jingqun; Huang, Xiaodan; Zhang, Zheng; Wang, Yao; Yu, Yibo; Yao, Ke

    2015-01-01

    To investigate the penetration of 0.3% gatifloxacin ophthalmic gel, 0.3% gatifloxacin ophthalmic solution and 0.5% levofloxacin ophthalmic solution into aqueous humor after topical application. Age-related cataract patients (150 eyes in 150 cases) receiving phacoemulsification were randomly divided into three groups: a 0.3% gatifloxacin gel group (n=50), a 0.3% gatifloxacin solution group (n=50), and a 0.5% levofloxacin solution group (n=50). Each group was administered one drop of gel or solution every 15 minutes for four doses. Aqueous samples were collected at different time points after the last drop. High pressure liquid chromatography (HPLC) was applied to determine the concentrations. The one-way ANOVA analysis was performed. Our data indicated that the concentration of the gatifloxacin gel group was higher than that of the gatifloxacin solution group at all time points (P solution group at 120.0 min and 180.0 min (Psolutions reached their peak values at 60.0 min. 0.3% gatifloxacin ophthalmic gel application produced highest aqueous humor drug concentration, maintained the longest time, had the best penetration and bioavailability.

  12. 78 FR 27971 - Determination That REV-EYES (Dapiprazole Hydrochloride Ophthalmic Solution), 0.5%, Was Not...

    Science.gov (United States)

    2013-05-13

    ...] Determination That REV-EYES (Dapiprazole Hydrochloride Ophthalmic Solution), 0.5%, Was Not Withdrawn From Sale... ophthalmic solution), 0.5%, was not withdrawn from sale for reasons of safety or effectiveness. This... ophthalmic solution, 0.5%, if all other legal and regulatory requirements are met. FOR FURTHER INFORMATION...

  13. A vision for an ultra-high resolution integrated water cycle observation and prediction system

    Science.gov (United States)

    Houser, P. R.

    2013-05-01

    biomass would improve soil-moisture retrieval by avoiding the need for auxiliary vegetation information. This multivariable water-cycle observation system must be integrated with high-resolution, application relevant prediction systems to optimize their information content and utility is addressing critical water cycle issues. One such vision is a real-time ultra-high resolution locally-moasiced global land modeling and assimilation system, that overlays regional high-fidelity information over a baseline global land prediction system. Such a system would provide the best possible local information for use in applications, while integrating and sharing information globally for diagnosing larger water cycle variability. In a sense, this would constitute a hydrologic telecommunication system, where the best local in-situ gage, Doppler radar, and weather station can be shared internationally, and integrated in a consistent manner with global observation platforms like the multivariable water cycle mission. To realize such a vision, large issues must be addressed, such as international data sharing policy, model-observation integration approaches that maintain local extremes while achieving global consistency, and methods for establishing error estimates and uncertainty.

  14. In vitro testing of thiolated poly(aspartic acid) from ophthalmic formulation aspects.

    Science.gov (United States)

    Budai-Szű Cs, Mária; Horvát, Gabriella; Gyarmati, Benjámin; Szilágyi, Barnabás Áron; Szilágyi, András; Csihi, Tímea; Berkó, Szilvia; Szabó-Révész, Piroska; Mori, Michela; Sandri, Giuseppina; Bonferoni, Maria Cristina; Caramella, Carla; Csányi, Erzsébet

    2016-08-01

    Ocular drug delivery formulations must meet anatomical, biopharmaceutical, patient-driven and regulatory requirements. Mucoadhesive polymers can serve as a better alternative to currently available ophthalmic formulations by providing improved bioavailability. If all requirements are addressed, a polymeric formulation resembling the tear film of the eye might be the best solution. The optimum formulation must not have high osmotic activity, should provide appropriate surface tension, pH and refractive index, must be non-toxic and should be transparent and mucoadhesive. We would like to highlight the importance of in vitro polymer testing from a pharmaceutical aspect. We, therefore, carried out physical-chemical investigations to verify the suitability of certain systems for ophthalmic formulations. In this work, in situ gelling, mucoadhesive thiolated poly(aspartic acid)s were tested from ophthalmic formulation aspects. The results of preformulation measurements indicate that these polymers can be used as potential carriers in ophthalmic drug delivery.

  15. Comparison of the effectiveness of contemporary ophthalmic lenses against β radiation

    International Nuclear Information System (INIS)

    Dunlap, J.H.; Harvey, P.W.; Schwing, R.L.

    1977-01-01

    As part of a study intended to identify the lens material and type that provides maximum eye protection against beta radiation, the effectiveness of contemporary ophthalmic lenses has been evaluated. From the calculations and measurements presented it is evident that safety glasses with crown glass ophthalmic lenses afford the eye the greatest protection against beta radiation, whereas street glasses with plastic ophthalmic lenses afford the eye very little protection. It is to be noted that glass street lenses (approximately 2.2 mm thick) provide greater protection than plastic safety lenses (approximately 3.5 mm thick). A warning is given against the use of safety lenses containing a large percentage of thorium. (U.K.)

  16. Molecular-level evidence provided by ultrahigh resolution mass spectrometry for oil-derived doc in groundwater at Bemidji, Minnesota

    Science.gov (United States)

    Islam, Ananna; Ahmed, Arif; Hur, Manhoi; Thorn, Kevin A.; Kim, Sunghwan

    2016-01-01

    Dissolved organic matter samples extracted from ground water at the USGS Bemidji oil spill site in Minnesota were investigated by ultrahigh resolution mass spectrometry. Principle component analysis (PCA) of the elemental composition assignments of the samples showed that the score plots for the contaminated sites were well separated from those for the uncontaminated sites. Additionally, spectra obtained from the same sampling site 7 and 19 years after the spill were grouped together in the score plot, strongly suggesting a steady state of contamination within the 12 year interval. The double bond equivalence (DBE) of Ox class compounds was broader for the samples from the contaminated sites, because of the complex nature of oil and the consequent formation of compounds with saturated and/or aromatic structures from the oxygenated products of oil. In addition, Ox class compounds with a relatively smaller number of x (x < 8; x = number of oxygen) and OxS1 class compounds were more abundant in the samples from the contaminated sites, because of the lower oxygen and higher sulfur contents of the oil compared to humic substances. The molecular-level signatures presented here can be a fundamental basis for in-depth analysis of oil contamination.

  17. Oligomers, organosulfates, and nitrooxy organosulfates in rainwater identified by ultra-high resolution electrospray ionization FT-ICR mass spectrometry

    Directory of Open Access Journals (Sweden)

    K. E. Altieri

    2009-04-01

    Full Text Available Wet deposition is an important removal mechanism for atmospheric organic matter, and a potentially important input for receiving ecosystems, yet less than 50% of rainwater organic matter is considered chemically characterized. Precipitation samples collected in New Jersey, USA, were analyzed by negative ion ultra-high resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS. Elemental compositions of 552 unique molecular species were determined in the mass range 50–500 Da in the rainwater. Four main groups of organic compounds were identified: compounds containing carbon, hydrogen, and oxygen (CHO only, sulfur (S containing CHOS compounds, nitrogen (N containing CHON compounds, and S- and N- containing CHONS compounds. Organic acids commonly identified in precipitation were detected in the rainwater. Within the four main groups of compounds detected in the rainwater, oligomers, organosulfates, and nitrooxy-organosulfates were assigned based on elemental formula comparisons. The majority of the compounds identified are products of atmospheric reactions and are known contributors to secondary organic aerosol (SOA formed from gas phase, aerosol phase, and in-cloud reactions in the atmosphere. It is suggested that the large uncharacterized component of SOA is the main contributor to the large uncharacterized component of rainwater organic matter.

  18. 76 FR 71044 - Determination That TRAVATAN (Travoprost Ophthalmic Solution), 0.004%, Was Not Withdrawn From Sale...

    Science.gov (United States)

    2011-11-16

    ...] Determination That TRAVATAN (Travoprost Ophthalmic Solution), 0.004%, Was Not Withdrawn From Sale for Reasons of... Drug Administration (FDA) has determined that TRAVATAN (travoprost ophthalmic solution), 0.004%, was... approve abbreviated new drug applications (ANDAs) for travoprost ophthalmic solution, 0.004%, if all other...

  19. Characterization of unknown iodinated disinfection byproducts during chlorination/chloramination using ultrahigh resolution mass spectrometry

    International Nuclear Information System (INIS)

    Wang, Xin; Wang, Juan; Zhang, Yahe; Shi, Quan; Zhang, Haifeng; Zhang, Yu; Yang, Min

    2016-01-01

    Iodinated disinfection byproducts (I-DBPs), formed from the reaction of disinfectant(s) with organic matter in the presence of iodide in raw water, have recently been focused because of their more cytotoxic and genotoxic properties than their chlorinated or brominated analogues. To date, only a few I-DBPs in drinking water have been identified. In this study, C18 solid phase extraction coupled with electrospray ionization ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS) was used to characterize unknown I-DBPs in chloraminated/chlorinated water spiked with iodide and humic substances. In total, 178 formulas for one-iodine-containing products, 13 formulas for two-iodine-containing products, and 15 formulas for one-chlorine and one-iodine-containing products were detected in the chloraminated water sample, while only 9 formulas for one-iodine-containing products and 6 formulas for one-chlorine and one-iodine-containing products were found in the chlorinated water sample. Most I-DBPs have corresponding chlorine-containing analogues with identical CHO compositions. As indicated by the modified aromaticity index (AI mod ), in the C18 extracts, more than 68% of the I-DBPs have aromatic structures or polycyclic aromatic structures. This result demonstrates that the use of chloramination as an alternative disinfection method may lead to the formation of abundant species of I-DBPs in the presence of iodide. Thus, the suitability of adopting chloramination as an alternative disinfection method should be reevaluated, particularly when iodide is present in raw water. - Highlights: • The formulas of 206 iodinated DBPs in chloraminated drinking water were proposed. • More than 68% of the I-DBPs might have aromatic or polycyclic aromatic structures. • Precursors with high aromaticity is preferential to form iodinated DBPs.

  20. Characterization of unknown iodinated disinfection byproducts during chlorination/chloramination using ultrahigh resolution mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xin; Wang, Juan [State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Zhang, Yahe; Shi, Quan [State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China); Zhang, Haifeng; Zhang, Yu [State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Yang, Min, E-mail: yangmin@rcees.ac.cn [State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China)

    2016-06-01

    Iodinated disinfection byproducts (I-DBPs), formed from the reaction of disinfectant(s) with organic matter in the presence of iodide in raw water, have recently been focused because of their more cytotoxic and genotoxic properties than their chlorinated or brominated analogues. To date, only a few I-DBPs in drinking water have been identified. In this study, C18 solid phase extraction coupled with electrospray ionization ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS) was used to characterize unknown I-DBPs in chloraminated/chlorinated water spiked with iodide and humic substances. In total, 178 formulas for one-iodine-containing products, 13 formulas for two-iodine-containing products, and 15 formulas for one-chlorine and one-iodine-containing products were detected in the chloraminated water sample, while only 9 formulas for one-iodine-containing products and 6 formulas for one-chlorine and one-iodine-containing products were found in the chlorinated water sample. Most I-DBPs have corresponding chlorine-containing analogues with identical CHO compositions. As indicated by the modified aromaticity index (AI{sub mod}), in the C18 extracts, more than 68% of the I-DBPs have aromatic structures or polycyclic aromatic structures. This result demonstrates that the use of chloramination as an alternative disinfection method may lead to the formation of abundant species of I-DBPs in the presence of iodide. Thus, the suitability of adopting chloramination as an alternative disinfection method should be reevaluated, particularly when iodide is present in raw water. - Highlights: • The formulas of 206 iodinated DBPs in chloraminated drinking water were proposed. • More than 68% of the I-DBPs might have aromatic or polycyclic aromatic structures. • Precursors with high aromaticity is preferential to form iodinated DBPs.

  1. Development and Evaluation of Diclofenac Sodium Loaded-N-Trimethyl Chitosan Nanoparticles for Ophthalmic Use.

    Science.gov (United States)

    Asasutjarit, Rathapon; Theerachayanan, Thitaree; Kewsuwan, Prartana; Veeranodha, Sukitaya; Fuongfuchat, Asira; Ritthidej, Garnpimol C

    2015-10-01

    The ophthalmic preparation of diclofenac sodium (DC) for relieving ocular inflammation is presently available in the market only as an eye drop solution. Due to its low occular bioavailability, it requires frequent application leading to low patients' compliance and quality of life. This study was conducted to develop formulations of DC loaded-N-trimethyl chitosan nanoparticles (DC-TMCNs) for ophthalmic use to improve ocular biavailabiltiy of DC. DC-TMCNs varied in formulation compositions were prepared using ionic gelation technique and evaluated for their physicochemical properties, drug release, eye irritation potential, and ophthalmic absorption of diclofenac sodium. N-Trimethyl chitosan (TMC) with a 49.8% degree of quaternization was synthesized and used for DC-TMCNs production. The obtained DC-TMCNs had particle size in a range of 130-190 nm with zeta potential values of +4 to +9 mV and drug entrapment efficiencies of more than 70% depending on the content of TMC and sodium tripolyphosphate (TPP). The optimized DC-TMCNs formulation contained TMC, DC, and TPP at a weight ratio of TMC/DC/TPP = 3:1:1. Their lyophilized product reconstituted with phosphate buffer solution pH 5.5 possessed a drug release pattern that fitted within the zero-order model. The eye irritation tests showed that DC-TMCNs were safe for ophthalmic use. The in vivo ophthalmic drug absorption study performed on rabbits indicated that DC-TMCNs could improve ophthalmic bioavailability of DC. Results of this study suggested that DC-TMCNs had potential for use as an alternative to conventional DC eye drops for ophthalmic inflammation treatment.

  2. A Profile of Neuro-Ophthalmic Practice Around the World.

    Science.gov (United States)

    Frohman, Larry P

    2018-03-01

    To compare contrast neuro-ophthalmic practice in various countries, an 18-question survey was sent to the international North American Neuro-Ophthalmology Society (NANOS) members in the spring of 2016. At least 1 NANOS member was contacted for each non-US nation in the NANOS membership roster. If there were multiple NANOS members from 1 country, multiple were contacted. If responses were received from more than 1 person from a single country, the first response received was used as the source data. The survey (in English) was emailed to 47 NANOS members from 31 countries. Twenty responses were received representing members from 15 nations. In all 15 nations, at least half of the neuro-ophthalmologists were trained as ophthalmologists. In 60% of nations, at least half of the neuro-ophthalmologists were trained internally, whereas in 33% of countries, at least half were trained in the United States. The number of physicians who practiced a significant amount of neuro-ophthalmology ranged from low (0.08/million, India) to high (3.10/million, Israel). Countries having the highest percentage of neuro-ophthalmologists exclusively practicing neuro-ophthalmology also were those with better patient access to neuro-ophthalmic care. Requirement of approval to see a neuro-ophthalmologist or for imaging studies requested by neuro-ophthalmologists was not typical. In most nations, academic neuro-ophthalmologists were paid a straight salary. In no nation were neuro-ophthalmologists paid more than another ophthalmic subspecialty. Individual national health care system designs and compensation models have had a profound influence on the rewards and challenges that face neuro-ophthalmologists. There seems to have been a connection between recognition of the discipline, financial rewards of neuro-ophthalmic practice, conditions that permit full-time neuro-ophthalmic practice, and patient access to care. A higher percentage of gross national product for health care did not seem to

  3. IN-SITU OPHTHALMIC GELS FOR THE TREATMENT OF EYE DISEASES

    OpenAIRE

    M. Jothi, S.L. Harikumar* and Geeta Aggarwal

    2012-01-01

    Topical administration of a drug in the conjunctival cul-de-sac is the treatment of choice for diseases of the anterior segment of eye. Development of ophthalmic drug delivery systems has always been challenging because of the drawbacks with this route, like non-productive absorption, drainage, induced lacrimation, tear turn over, impermeability of drugs to cornea. New approaches have been investigated for delivery of drugs to the eye by means of polymeric delivery of ophthalmic drugs to the ...

  4. An Ultrahigh Resolution Structure of TEM-1 β-Lactamase Suggests a Role for Glu166 as the General Base in Acylation

    International Nuclear Information System (INIS)

    Minasov, George; Wang, Xiaojun; Shoichet, Brian K.

    2002-01-01

    Although TEM-1 β-lactamase is among the best studied enzymes, its acylation mechanism remains controversial. To investigate this problem, the structure of TEM-1 in complex with an acylation transition-state analogue was determined at ultrahigh resolution (0.85 (angstrom)) by X-ray crystallography. The quality of the data was such as to allow for refinement to an R-factor of 9.1% and an R free of 11.2%. In the resulting structure, the electron density features were clear enough to differentiate between single and double bonds in carboxylate groups, to identify multiple conformations that are occupied by residues and loops, and to assign 70% of the protons in the protein. Unexpectedly, even at pH 8.0 where the protein was crystallized, the active site residue Glu166 is clearly protonated. This supports the hypothesis that Glu166 is the general base in the acylation half of the reaction cycle. This structure suggests that Glu166 acts through the catalytic water to activate Ser70 for nucleophilic attack on the β-lactam ring of the substrate. The hydrolytic mechanism of class A β-lactamases, such as TEM-1, appears to be symmetrical, as are the serine proteases. Apart from its mechanistic implications, this atomic resolution structure affords an unusually detailed view of the structure, dynamics, and hydrogen-bonding networks of TEM-1, which may be useful for the design of inhibitors against this key antibiotic resistance target.

  5. Fragmentation analysis of water-soluble atmospheric organic matter using ultrahigh-resolution FT-ICR mass spectrometry.

    Science.gov (United States)

    Leclair, Jeffrey P; Collett, Jeffrey L; Mazzoleni, Lynn R

    2012-04-17

    Isolated water-soluble atmospheric organic matter (AOM) analytes extracted from radiation fogwater samples were analyzed using collision induced dissociation with ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Tandem mass analysis was performed on several mass ranges between 100 and 400 Da to characterize the functional groups of AOM species. Compounds containing nitrogen and/or sulfur were targeted because of the high number of oxygen atoms contained in their molecular formulas. Due to the large number of isobaric ions in the precursor isolation ranges, large numbers of product ions resulted from collision induced dissociation. Common neutral losses were assigned by matching the molecular formulas of the expected product ions with the detected product ions within the appropriate mass spectra. Since polar functional groups are expected to affect the hygroscopic properties of aerosols, the losses of H(2)O, CO(2), CH(3)OH, HNO(3), CH(3)NO(3), SO(3), SO(4) and combinations of these were specifically targeted. Among the 421 compounds studied, the most frequently observed neutral losses were CO(2) (54%), H(2)O (43%) and CH(3)OH (40%). HNO(3) losses were observed for 63% of the studied nitrogen containing compounds and 33% of the studied compounds containing both nitrogen and sulfur. SO(3) losses were observed for 85% of the studied sulfur containing compounds and 42% of studied compounds containing both nitrogen and sulfur. A number of molecular formulas matching those of monoterpene ozonolysis SOA were observed; they include organonitrates, organosulfates, and nitroxy-organosulfates. Overall, the results of fragmentation analysis of 400+ individual molecular precursors elucidate the complexity and multifunctional nature of the isolated water-soluble AOM.

  6. Efficacy of bromfenac sodium ophthalmic solution for treatment of dry eye disease.

    Science.gov (United States)

    Fujishima, Hiroshi; Fuseya, Miki; Ogata, Masarou; Murat, Dogru

    2015-01-01

    To evaluate the efficacy of bromfenac sodium ophthalmic solution (BF) in patients with dry eye disease (DED) inadequately controlled by monotherapy with artificial tears (ATs). An investigator-oriented trial with a single-arm, nonrandomized, open-label design. Twenty-six patients, who showed no symptomatic improvement of DED after 1 month of AT treatment, were enrolled. Bromfenac sodium ophthalmic solution was administered adjunctively with AT for 1 month. The BF treatment was then discontinued, and AT treatment alone was continued for 3 months. The signs and symptoms were evaluated at the beginning of BF treatment (Pre), at the end of the combined BF and AT treatment (BF1M), and at 1 and 3 months after discontinuation of BF treatment (Po1M and Po3M, respectively). The dryness scores at BF1M were significantly improved compared with Pre (P ophthalmic solution has improved the dryness of the eye and signs of DED through its anti-inflammatory effects. Nonsteroidal anti-inflammatory drugs were suitable as anti-inflammatory ophthalmic solutions for patients with DED.

  7. Determination of Triazine Herbicides in Drinking Water by Dispersive Micro Solid Phase Extraction with Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometric Detection.

    Science.gov (United States)

    Chen, Dawei; Zhang, Yiping; Miao, Hong; Zhao, Yunfeng; Wu, Yongning

    2015-11-11

    A novel dispersive micro solid phase extraction (DMSPE) method based on a polymer cation exchange material (PCX) was applied to the simultaneous determination of the 30 triazine herbicides in drinking water with ultrahigh-performance liquid chromatography-high-resolution mass spectrometric detection. Drinking water samples were acidified with formic acid, and then triazines were adsorbed by the PCX sorbent. Subsequently, the analytes were eluted with ammonium hydroxide/acetonitrile. The chromatographic separation was performed on an HSS T3 column using water (4 mM ammonium formate and 0.1% formic acid) and acetonitrile (0.1% formic acid) as the mobile phase. The method achieved LODs of 0.2-30.0 ng/L for the 30 triazines, with recoveries in the range of 70.5-112.1%, and the precision of the method was better than 12.7%. These results indicated that the proposed method had the advantages of convenience and high efficiency when applied to the analysis of the 30 triazines in drinking water.

  8. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Science.gov (United States)

    Dubald, Marion; Bourgeois, Sandrine; Andrieu, Véronique; Fessi, Hatem

    2018-01-01

    The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites. PMID:29342879

  9. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Directory of Open Access Journals (Sweden)

    Marion Dubald

    2018-01-01

    Full Text Available The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites.

  10. Subspecialization of the ophthalmic literature: a review of the publishing trends of the top general, clinical ophthalmic journals.

    Science.gov (United States)

    Kumar, Anupma; Cheeseman, Robert; Durnian, Jonathan M

    2011-06-01

    To investigate the publishing trends of the top general clinical ophthalmic journals and to report: (1) the proportions of articles published in terms of ophthalmic subspecialty, (2) the study design used, (3) any changes in publishing trends, and (4) any differences in the quality of study design between the subspecialties. Retrospective, database review. All original articles published in the top general, clinical ophthalmology journals from 2005 through 2009. All general, clinical ophthalmic journals were selected from the top 20 journals based on 2008 impact factor. All abstracts from original articles were reviewed, and the subject matter was recorded as belonging to 1 of the 11 ophthalmic subspecialties. After the content of the article was assigned, then the study design was recorded as one of the following: nonanalytic study, case-control or cohort study, randomized control trial, meta-analysis, laboratory science article, or systemic review. Subspecialty of the article and the study design used. Seven journals were included, and 12 426 abstracts were reviewed. Articles relating to medical retina were the most prevalent (29.1%), and those relating to strabismus were the least prevalent (2.3%). Case-control or cohort studies comprised most study designs (40.1%), with meta-analyses comprising the least (0.3%). The mean number of articles per year was 2485 (standard deviation, 125.1), remaining stable over the study period. Medical retina articles were significantly more common in 2009 than in 2005 (chi-square, 11.2; P = 0.0008), whereas the proportion of oculoplastic articles was significantly reduced (chi-square, 16.9; P<0.0001). Cataract and refractive surgery had the highest proportions of articles using the higher forms of study design (7.8%), and oculoplastics had the highest proportion of nonanalytic studies (64.5%). There are great differences across the specialty of ophthalmology in the subject matter of published literature, probably driven by recent

  11. Ophthalmic Start-Up Chief Executive Officers' Perceptions of Development Hurdles.

    Science.gov (United States)

    Stewart, William C; Nelson, Lindsay A; Kruft, Bonnie; Stewart, Jeanette A

    2018-01-01

    To identify current challenges facing ophthalmic pharmaceutical start-ups in developing new products. Surveys were distributed to the chief executive officer (CEO) or president of ophthalmic start-ups. The survey attracted 24 responses from 78 surveys distributed (31%). The CEOs stated that a lack of financial capital (n = 18, 75%), FDA regulations (n = 6, 25%), and failure to meet clinical endpoints (n = 6, 25%) were their greatest development hurdles. Risk aversion to medicines in early development (n = 18, 75%), mergers and acquisitions reducing corporate choice for licensing agreements (n = 7, 29%), the emergence of large pharmaceutical-based venture capital funding groups (n = 12, 50%), and the failure of many large pharmaceutical companies to develop their own medicines (n = 10, 42%) were noted as recent prominent trends affecting fundraising. The study suggests that development funding, regulatory burden, and meeting clinical endpoints are the greatest development challenges faced by ophthalmic start-up CEOs. © 2017 S. Karger AG, Basel.

  12. Formulation and stability of an extemporaneous 0.02% chlorhexidine digluconate ophthalmic solution

    Directory of Open Access Journals (Sweden)

    Shu-Chiao Lin

    2015-12-01

    Conclusion: The acetate-buffered 0.02% chlorhexidine digluconate ophthalmic solution stored in light-resistant high-density polyethylene eyedroppers demonstrated excellent stability at 2–25°C for 6 months after being sealed and for 1 month after opening. This finding will enable us to prepare 0.02% chlorhexidine digluconate ophthalmic solutions based on a doctor's prescription.

  13. In situ ultrahigh-resolution optical coherence tomography characterization of eye bank corneal tissue processed for lamellar keratoplasty.

    Science.gov (United States)

    Brown, Jamin S; Wang, Danling; Li, Xiaoli; Baluyot, Florence; Iliakis, Bernie; Lindquist, Thomas D; Shirakawa, Rika; Shen, Tueng T; Li, Xingde

    2008-08-01

    To use optical coherence tomography (OCT) as a noninvasive tool to perform in situ characterization of eye bank corneal tissue processed for lamellar keratoplasty. A custom-built ultrahigh-resolution OCT (UHR-OCT) was used to characterize donor corneal tissue that had been processed for lamellar keratoplasty. Twenty-seven donor corneas were analyzed. Four donor corneas were used as controls, whereas the rest were processed into donor corneal buttons for lamellar transplantation by using hand dissection, a microkeratome, or a femtosecond laser. UHR-OCT was also used to noninvasively characterize and monitor the viable corneal tissue immersed in storage medium over 3 weeks. The UHR-OCT captured high-resolution images of the donor corneal tissue in situ. This noninvasive technique showed the changes in donor corneal tissue morphology with time while in storage medium. The characteristics of the lamellar corneal tissue with each processing modality were clearly visible by UHR-OCT. The in situ characterization of the femtosecond laser-cut corneal tissue was noted to have more interface debris than shown by routine histology. The effects of the femtosecond laser microcavitation bubbles on the corneal tissue were well visualized at the edges of the lamellar flap while in storage medium. The results of our feasibility study show that UHR-OCT can provide superb, in situ microstructural characterization of eye bank corneal tissue noninvasively. The UHR-OCT interface findings and corneal endothelial disc thickness uniformity analysis are valuable information that may be used to optimize the modalities and parameters for lamellar tissue processing. The UHR-OCT is a powerful approach that will allow us to further evaluate the tissue response to different processing techniques for posterior lamellar keratoplasty. It may also provide information that can be used to correlate with postoperative clinical outcomes. UHR-OCT has the potential to become a routine part of tissue

  14. Characterization of Soft Contact Lens Edge Fitting during Daily Wear Using Ultrahigh-Resolution Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Lele Cui

    2018-01-01

    Full Text Available Purpose. To determine conjunctival overlap over the edge of soft contact lens and to visualize the peripheral postlens tear film (PoLTF underneath soft contact lenses using ultrahigh-resolution optical coherence tomography (UHR-OCT. Methods. Twenty participants (4 males and 16 females, 23.0 ± 3.7 years were fitted with two different types of soft contact lenses randomly. The limbus with lens was imaged with the UHR-OCT at the horizontal meridian every two hours up to 6 hours during lens wear. The conjunctival overlap was ranked as the percentage of the edge covered by the conjunctiva. The frequency of occurrence for visualized peripheral PoLTF was determined. Results. The average conjunctival overlaps at insertion were 49% and 73% for galyfilcon A and balafilcon A lenses and increased significantly to 84% and 90% by 6 hours of lens wear (P<0.001. Lenses with rounded edges had more conjunctival overlap than the lenses with angled edges (P=0.014. There were significant decreases for PoLTF on the conjunctiva (P=0.014 and peripheral cornea (P=0.004 over the study period compared to insertion. The percentage of subjects with PoLTF on the conjunctiva (32.5% and peripheral cornea (36% were greater in subjects wearing balafilcon A lenses (P=0.017. Conclusions. Increased conjunctival overlap over the lens edges and reduced PoLTF underneath the peripheral region of soft contact lenses were shown during lens daily wear. The lens edge configuration may play a role in conjunctival response and peripheral PoLTF.

  15. Ultra-flattened nearly-zero dispersion and ultrahigh nonlinear slot silicon photonic crystal fibers with ultrahigh birefringence

    Science.gov (United States)

    Liao, Jianfei; Xie, Yingmao; Wang, Xinghua; Li, Dongbo; Huang, Tianye

    2017-07-01

    A slot silicon photonic crystal fiber (PCF) is proposed to simultaneously achieve ultrahigh birefringence, large nonlinearity and ultra-flattened nearly-zero dispersion over a wide wavelength range. By taking advantage on the slot effect, ultrahigh birefringence up to 0.0736 and ultrahigh nonlinear coefficient up to 211.48 W-1 m-1 for quasi-TE mode can be obtained at the wavelength of 1.55 μm. Moreover, ultra-flattened dispersion of 0.49 ps/(nm km) for quasi-TE mode can be achieved over a 180 nm wavelength range with low dispersion slope of 1.85 × 10-3 ps/(nm2 km) at 1.55 μm. Leveraging on these advantages, the proposed slot PCF has great potential for efficient all-optical signal processing applications.

  16. Detailed Source-Specific Molecular Composition of Ambient Aerosol Organic Matter Using Ultrahigh Resolution Mass Spectrometry and 1H NMR

    Directory of Open Access Journals (Sweden)

    Amanda S. Willoughby

    2016-06-01

    Full Text Available Organic aerosols (OA are universally regarded as an important component of the atmosphere that have far-ranging impacts on climate forcing and human health. Many of these impacts are related to OA molecular characteristics. Despite the acknowledged importance, current uncertainties related to the source apportionment of molecular properties and environmental impacts make it difficult to confidently predict the net impacts of OA. Here we evaluate the specific molecular compounds as well as bulk structural properties of total suspended particulates in ambient OA collected from key emission sources (marine, biomass burning, and urban using ultrahigh resolution mass spectrometry (UHR-MS and proton nuclear magnetic resonance spectroscopy (1H NMR. UHR-MS and 1H NMR show that OA within each source is structurally diverse, and the molecular characteristics are described in detail. Principal component analysis (PCA revealed that (1 aromatic nitrogen species are distinguishing components for these biomass burning aerosols; (2 these urban aerosols are distinguished by having formulas with high O/C ratios and lesser aromatic and condensed aromatic formulas; and (3 these marine aerosols are distinguished by lipid-like compounds of likely marine biological origin. This study provides a unique qualitative approach for enhancing the chemical characterization of OA necessary for molecular source apportionment.

  17. An international strategic plan to preserve and restore vision: four curricula of ophthalmic education.

    Science.gov (United States)

    Tso, Mark O M; Goldberg, Morton F; Lee, Andrew G; Selvarajah, Sivaguru; Parrish, Richard K; Zagorski, Zbigniew

    2007-05-01

    To highlight the four International Curricula of Ophthalmic Education developed by the Task Forces of the International Council of Ophthalmology, published in Klinische Monatsblätter für Augenheilkunde in November 2006. A global perspective of developing educational curricula as tools to improve eye care. Review of the experience and conclusions of the four international panels. The Task Force on Resident and Specialist Education developed a curriculum consisting of 15 topics in basic, standard, and advanced levels to provide flexibility of educational programs of the ophthalmic specialist in different locations across the world. The curricula were designed to be an educational tool to stimulate multiple levels of training of the ophthalmic specialist. The Task Force on Ophthalmic Education of Medical Students designed a curriculum covering 11 topics and provides illustrative materials for teachers and students. The Task Force strongly advocates the ophthalmology curriculum to be part of the core program of general medical schools education. The Task Force on Para-ophthalmic Vision Specialist Education developed a curriculum to highlight the importance of a team approach to eye care, consisting of ophthalmic specialists and paraophthalmic personnel to produce maximum efficiency. The Task Force on Continuing Medical Education (CME) designed a curriculum exploring the principles, elements, categories, and administration of CME activities in a variety of topics. These curricula shifted the traditional apprentice system of education to a curriculum-based training program in which goals, expectations, competencies, and technical training are defined to improve eye care worldwide.

  18. 21 CFR 349.14 - Ophthalmic emollients.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Ophthalmic emollients. 349.14 Section 349.14 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR.... (4) Petrolatum, up to 100 percent. (5) White ointment, up to 100 percent. (6) White petrolatum, up to...

  19. Absorbed doses to the main parts of eyeball due to use 90Sr + 90Y ophthalmic applicator

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-05-01

    The ophthalmic radiotherapy dosimetry and some affecting factors are introduced. The distributions of absorbed doses to the main parts of a fresh eyeball such as the cornea, sclera, lens and anterior chamber, during the radiotherapy by using a 90 Sr + 90 Y ophthalmic applicator are presented. An tissue-equivalent extrapolation ionization chamber was used in the dose measurement. The reasonable doses during ophthalmic radiotherapy for different depths have been obtained. Therefore, the absorbed dose to the lens, the most sensitive organ, can be given. These data are useful for radiation protection in ophthalmic radiotherapy

  20. Effect of textured eye drop bottles on the photostability of pranoprofen 0.1% ophthalmic solution.

    Science.gov (United States)

    Iwatsuka, Kinya; Inada, Katsuhiro; Ueoka, Hiroki; Otsuka, Tadashi; Maeda, Masaki; Yamaguchi, Masazumi; Yasueda, Shin-ichi

    2015-01-01

    Ophthalmic solutions are usually filled in a plastic bottle due to its durability and disposability. In Japan, photostability is one of the concerns for the quality control because an eye drop bottle must be a transparent container. The present work studied the effect of textured eye drop bottles on its light blocking to improve the photostability of ophthalmic solutions. We investigated the photostability of Pranoprofen ophthalmic solution filled in a variety of textured eye drop bottles. Pranoprofen content was analyzed by high-performance liquid chromatography and surface structure of textured eye drop bottles was evaluated by transmittance, calculated average roughness (Ra) and haze intensity. We observed that eye drop bottle which had greater than Ra value of 1.0 µm and haze intensity 62% clearly showed photostability improvement. This report is the first one which shows that photostability of ophthalmic solution is improved by using textured eye drop bottle. Moreover, this approach is a simple and effective method to improve the photostability. This method is available for not only various ophthalmic applications but also other liquid pharmaceuticals or food products.

  1. Dural AVM supplied by the ophthalmic artery.

    LENUS (Irish Health Repository)

    Flynn, T H

    2012-02-03

    Dural arteriovenous malformations in the anterior cranial fossa are rare and are especially prone to haemorrhage. These lesions are usually treated by surgical excision. We report the embolization of an anterior cranial fossa DAVM using an endovascular approach via the ophthalmic artery.

  2. Radioactivity measurements for some ophthalmic glasses

    International Nuclear Information System (INIS)

    Badawy, W.M.; Ali, E.M.; Gomaa, M.A.; Hussein, A

    2007-01-01

    The main aim of the present work is to implant the latest ICRP/IAEA recommendations related to exemption and clearness to the Ophthalmic Glass. As consumer product, glass lenses may contain trace quantities of uranium, thorium and potassium. Glass lenses under investigation were monitored for the detection of gamma rays and beta particles using radiation measuring devices. Using high purity germanium detector radioactivity concentration was estimated in Bq/kg. Activity concentration of 226 Ra, Th-232 and K-40 were determined using the energy gamma lines of 2l4 Pb (352 keV), 212 Pb (238 keV) and 1460 keV gamma line for 40 K respectively .Experimental results showed that radioactivity concentration for radium -226 varies from 0.19 to 4.98 Bq/kg of radium-226, from to 0.18 to 2.83 Bq/kg for thorium -232 and from 0.8 to 1.13 Bq/kg for potassium. Implementing new ICRP recommendation of exemption and clearness indicated that several Ophthalmic Glass should not be in use

  3. Effects of viscoelastic ophthalmic solutions on cell cultures

    Directory of Open Access Journals (Sweden)

    Madhavan Hajib

    1998-01-01

    Full Text Available The development of mild but significant inflammation probably attributable to viscoelastic ophthalmic solutions in cataract surgery was recently brought to the notice of the authors, and hence a study of the effects of these solutions available in India, on cell cultures was undertaken. We studied the effects of 6 viscoelastic ophthalmic solutions (2 sodium hyaluronate designated as A and B, and 4 hydroxypropylmethylcellulose designated as C, D, E and F on HeLa, Vero and BHK-21 cell lines in tissue culture microtitre plates using undiluted, 1:10 and 1:100 dilutions of the solutions, and in cover slip cultures using undiluted solutions. Phase contrast microscopic examination of the solutions was also done to determine the presence of floating particles. The products D and F produced cytotoxic changes in HeLa cell line and these products also showed the presence of floating particles under phase contrast microscopy. Other products did not have any adverse effects on the cell lines nor did they show floating particles. The viscoelastic ophthalmic pharmaceutical products designated D and F have cytotoxic effects on HeLa cell line which appears to be a useful cell line for testing these products for their toxicity. The presence of particulate materials in products D and F indicates that the methods used for purification of the solution are not effective.

  4. Fe- and Cu-complex formation with artificial ligands investigated by ultra-high resolution Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR-MS: Implications for natural metal-organic complex studies

    Directory of Open Access Journals (Sweden)

    Hannelore Waska

    2016-07-01

    Full Text Available In recent years, electrospray-ionization mass spectrometry (ESI-MS has been increasingly used to complement the bulk determination of metal-ligand equilibria, for example via competitive ligand exchange-adsorptive cathodic stripping voltammetry (CLE-ACSV. However, ESI-MS speciation analyses may be impacted by instrumental artefacts such as reduction reactions, fragmentation, and adduct formation at the ESI source, changes in the ionization efficiencies of the detected species in relation to sample matrix, and peak overlaps in response to increasing sample complexity. In our study, equilibria of the known artificial ligands citrate, ethylenediaminetetraacetic acid (EDTA, 1-nitroso-2-naphthol (NN, and salicylaldoxime (SA with iron (Fe and copper (Cu were investigated by ultra-high resolution ESI-MS, Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR-MS, under a variety of sample matrix and ionization settings. The acquired mass spectra were compared with metal-ligand equilibrium data from the literature as well as an adapted speciation model. Overall, the mass spectra produced representative species mentioned in previous reports and predicted by the speciation calculations, such as Fe(Cit, Cu(Cit2, Fe(EDTA, Cu(EDTA, Fe(NN3, and Cu(SA2. The analyses furthermore revealed new species which had been hypothesized but not measured directly using other methods, for example ternary complexes of citrate with Fe and Cu, Cu(SA monomers, and the dimer Fe(SA2. Finally, parallel measurements of a Cu+SA calibration series and a Cu+SA+EDTA competition series indicated that FT-ICR-MS can produce linear responses and low detection limits analogous to those of ACSV. We propose that ultra-high resolution FT-ICR-MS can be used as a representative tool to study interactions of trace metals with artificial as well as natural, unknown ligands at the molecular level.

  5. 21 CFR 349.12 - Ophthalmic demulcents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Ophthalmic demulcents. 349.12 Section 349.12 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR....2 to 1 percent. (5) Propylene glycol, 0.2 to 1 percent. (e) Polyvinyl alcohol, 0.1 to 4 percent. (f...

  6. Ophthalmic implications of seasonal affective disorder

    International Nuclear Information System (INIS)

    Paramore, J.E.; King, V.M.

    1989-01-01

    A review of seasonal affective disorder (SAD) is presented with a discussion of its standard treatment of phototherapy. A number of ophthalmic implications related to SAD are proposed. These implications relate to both the condition and the phototherapy used in its treatment, especially the use of full spectrum light which contains ultraviolet and near ultraviolet radiation. 12 references

  7. [Tibolone's effect on retinal and ophthalmic arteries flowmetry].

    Science.gov (United States)

    Souza, Marco Aurélio Martins de; Geber, Selmo

    2008-11-01

    to evaluate the effect of tibolone use on doppler-velocimetric parameters of ophthalmic and retinal arteries. clinical, prospective, longitudinal, randomized, placebo-controlled, triple-blind study, in which among 100 menopausal women, 50 have used 2.5 mg of the active principle tibolone (Tib Group) and 50, placebo as a means to form the control-group (Plac Group). In the Tib Group, 44 of the 50 women returned after 84 days to finish the exams, and in the Plac Group, 47. The ophthalmic and retinal arteries were studied to determine the resistance index (RI), the pulsatility index (PI) and the systole/diastole ratio (S/D). Assessments have been done before and 84 days after medication. The t-Student test has been used for the comparison of means between the groups in independent samples, as well as for within-group comparisons in dependent samples. in both groups, the women's characteristics were similar in age, menopause duration, body mass index, arterial blood pressure, deliveries and cardiac rate. The Tib Group presented the following values in the ophthalmic artery: RI(pre)=0.71+/-0.05, RI(post)0.72+/-0.08 (p=0.43); PI(pre)=1.29+/-0.22, PI(post)=1.30+/-0.25 (p=0.4) and S/D(pre)=3.49+/-0.77, SD(post)=3.65+/-0.94 (p=0.32). In the retinal artery, the following values have been found: RI(pre)=0.67+/-0.09, RI(post)=0.69+/-0.10 (p=0.7); PI(pre)=1.20+/-0.29, PI(post)=1.22+/-0.3 (p=0.2) and SD(pre)=3.29+/-0.95, SD(post)=3.30+/-1.07 (p=0.3). Also, the tibolone and control groups did not show any significant difference in regard to the above indexes in the end of the study. the 2.5 mg dose of tibolone had no effect on the Doppler velocimetry indexes of the ophthalmic and retinal arteries.

  8. [Biological availability of ophthalmic drugs. 1. Increasing drug permeability in the cornea].

    Science.gov (United States)

    Masteiková, R; Chalupová, Z; Savickiene, N

    2004-03-01

    Most eye diseases are treated by topical administration of ophthalmic preparations. Low ophthalmic bioavailability is due to a number of physiological and physicochemical factors. The main obstacle to the penetration of active ingredients to the eye is the layered character of the cornea. Formulation of ophthalmic preparations enabling easier penetration of this biological barrier thus ranks among the most effective ways of improving bioavailability. Penetrability of the cornea can be increased by the following methods: a) adjustment of the actual acidity in such a way that pH of the preparation makes it possible to produce the optimal portion of non-ionized particles; b) incorporation of absorption enhancers (non-ionic tensides, salts of bile acids, some antimicrobial substances, EDTA, cyclodextrins, etc.) into the composition of the preparation, and c) production of prodrugs or ionic pairs.

  9. Access to the ophthalmic artery by retrograde approach through the posterior communicating artery for intra-arterial chemotherapy of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Chi-Tuan; Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Lumbroso-Le Rouic, Livia [Institut Curie, Department of Ocular Oncology, Paris (France)

    2012-08-15

    Intra-arterial infusion of chemotherapy into the ophthalmic artery for treatment of retinoblastoma has been realized after catheterization of the internal carotid and temporary balloon occlusion beyond the orifice of the ophthalmic artery, or more recently after superselective canulation of the ophthalmic artery by a microcatheter. The superselective catheterization of the ophthalmic artery could be cumbersome because of the implantation of the ostium on the carotid siphon or because of the tortuosity of the carotid siphon. We report our experience of using a retrograde approach through the posterior communicating artery that allows a more direct angle of access to the origin of the ophthalmic artery. (orig.)

  10. Long-term results of treatment with diquafosol ophthalmic solution for aqueous-deficient dry eye.

    Science.gov (United States)

    Koh, Shizuka; Ikeda, Chikako; Takai, Yoshihiro; Watanabe, Hitoshi; Maeda, Naoyuki; Nishida, Kohji

    2013-09-01

    To evaluate the preliminary long-term efficacy of diquafosol ophthalmic solution for aqueous-deficient dry eye. Fifteen patients with mild-to-moderate aqueous-deficient dry eye were enrolled. After a washout period, the patients were treated with 3 % diquafosol ophthalmic solution for 6 months. We assessed 12 subjective dry eye symptoms, corneal and conjunctival staining with fluorescein, tear film break-up time (BUT), lower tear meniscus height measured with anterior-segment optical coherence tomography, Schirmer's testing, and adverse reactions at baseline and 1, 3, and 6 months after the start of treatment. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining, BUT, and tear meniscus height at 1 month and maintained the effectiveness for 6 months. Conjunctival staining significantly improved 3 and 6 months after treatment. No significant adverse reactions developed. Prolonged use of diquafosol ophthalmic solution for 6 months produced significant improvement both subjectively (dry eye symptom score) and objectively (ocular staining score and tear function tests) for aqueous-deficient dry eye.

  11. Are we pharmacovigilant enough in ophthalmic practice?

    Directory of Open Access Journals (Sweden)

    Ashok Dubey

    2013-01-01

    Full Text Available No drug is absolutely safe. Pharmacovigilance is the science related to detection, assessment, understanding and prevention of adverse effects or any other possible drug-related problems. The ocular medications and devices can cause localized and systemic adverse effects. Not all adverse effects are known when a drug or device is launched in market because of limitations of clinical trials. Many adverse effects are recognized due to the spontaneous reporting of the vigilant doctors who observe and report such events encountered in their practice. Despite a large ophthalmic patient population base, India does not have robust adverse drug reaction (ADR database because of lack of reporting culture. Government of India recently launched the Pharmacovigilance Programme of India (PvPI to monitor ADRs and create awareness among the healthcare professionals about the importance of ADRs. Suspecting and reporting a possible drug reaction is very important in developing a safe and rational ophthalmic practice.

  12. Ophthalmic plastic and orbital surgery in Taiwan.

    Science.gov (United States)

    Hsu, Chi-Hsin; Lin, I-Chan; Shen, Yun-Dun; Hsu, Wen-Ming

    2014-06-01

    We describe in this paper the current status of ophthalmic plastic and orbital surgery in Taiwan. Data were collected from the Bureau of National Health Insurance of Taiwan, the Bulletin of the Taiwan Ophthalmic Plastic and Reconstructive Society, and the Statistics Yearbook of Practicing Physicians and Health Care Organizations in Taiwan by the Taiwan Medical Association. We ascertained that 94 ophthalmologists were oculoplastic surgeons and accounted for 5.8% of 1621 ophthalmologists in Taiwan. They had their fellowship training abroad (most ophthalmologists trained in the United States of America) or in Taiwan. All ophthalmologists were well trained and capable of performing major oculoplastic surgeries. The payment rates by our National Health Insurance for oculoplastic and orbital surgeries are relatively low, compared to Medicare payments in the United States. Ophthalmologists should promote the concept that oculoplastic surgeons specialize in periorbital plastic and aesthetic surgeries. However, general ophthalmologists should receive more educational courses on oculoplastic and cosmetic surgery. Copyright © 2014. Published by Elsevier B.V.

  13. Waveguide image-slicers for ultrahigh resolution spectroscopy

    Science.gov (United States)

    Beckert, Erik; Strassmeier, Klaus G.; Woche, Manfred; Eberhardt, Ramona; Tünnermann, Andreas; Andersen, Michael

    2008-07-01

    Waveguide image-slicer prototypes with resolutions up to 310.000 for the fiber fed PEPSI echelle spectrograph at the LBT and single waveguide thicknesses of down to 30 μm have been manufactured. The waveguides were macroscopically prepared, stacked up to an order of 7 and thinned back to square stack cross sections. A high filling ratio was achieved by realizing homogenous adhesive gaps of 4.6 μm, using index matching adhesives for TIR within the waveguides. The image-slicer stacks can be used in immersion mode and are miniaturized to be implemented in a set of four, measurements indicate an overall efficiency of above 80% for them.

  14. Development and Effects of FTY720 Ophthalmic Solution on Corneal Allograft Survival

    OpenAIRE

    Zhaochuan Liu; Haotian Lin; Chulong Huang; Wan Chen; Wu Xiang; Yu Geng; Weirong Chen

    2015-01-01

    Fingolimod (FTY720), a novel class of sphingosine 1-phosphate receptor modulators, has received special interest among ophthalmologists, particularly given that oral administration of FTY720 has proven to effectively treat corneal graft rejection in animal models. However, no studies have examined the performance of FTY720 as an ophthalmic solution in reducing corneal rejection in high-risk corneal rejection models, and the stability and ocular irritation profile of FTY720 ophthalmic solution...

  15. High-resolution functional MRI of the human amygdala at 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Sladky, Ronald, E-mail: ronald.sladky@meduniwien.ac.at [MR Centre of Excellence, Medical University of Vienna, Lazarettgasse 14, 1090 Vienna (Austria); Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Baldinger, Pia; Kranz, Georg S. [Department of Psychiatry and Psychotherapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Tröstl, Jasmin [MR Centre of Excellence, Medical University of Vienna, Lazarettgasse 14, 1090 Vienna (Austria); Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Höflich, Anna; Lanzenberger, Rupert [Department of Psychiatry and Psychotherapy, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Moser, Ewald [MR Centre of Excellence, Medical University of Vienna, Lazarettgasse 14, 1090 Vienna (Austria); Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria); Windischberger, Christian, E-mail: christian.windischberger@meduniwien.ac.at [MR Centre of Excellence, Medical University of Vienna, Lazarettgasse 14, 1090 Vienna (Austria); Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna (Austria)

    2013-05-15

    Functional magnetic resonance imaging (fMRI) has become the primary non-invasive method for investigating the human brain function. With an increasing number of ultra-high field MR systems worldwide possibilities of higher spatial and temporal resolution in combination with increased sensitivity and specificity are expected to advance detailed imaging of distinct cortical brain areas and subcortical structures. One target region of particular importance to applications in psychiatry and psychology is the amygdala. However, ultra-high field magnetic resonance imaging of these ventral brain regions is a challenging endeavor that requires particular methodological considerations. Ventral brain areas are particularly prone to signal losses arising from strong magnetic field inhomogeneities along susceptibility borders. In addition, physiological artifacts from respiration and cardiac action cause considerable fluctuations in the MR signal. Here we show that, despite these challenges, fMRI data from the amygdala may be obtained with high temporal and spatial resolution combined with increased signal-to-noise ratio. Maps of neural activation during a facial emotion discrimination paradigm at 7 T are presented and clearly show the gain in percental signal change compared to 3 T results, demonstrating the potential benefits of ultra-high field functional MR imaging also in ventral brain areas.

  16. High-resolution functional MRI of the human amygdala at 7 T

    International Nuclear Information System (INIS)

    Sladky, Ronald; Baldinger, Pia; Kranz, Georg S.; Tröstl, Jasmin; Höflich, Anna; Lanzenberger, Rupert; Moser, Ewald; Windischberger, Christian

    2013-01-01

    Functional magnetic resonance imaging (fMRI) has become the primary non-invasive method for investigating the human brain function. With an increasing number of ultra-high field MR systems worldwide possibilities of higher spatial and temporal resolution in combination with increased sensitivity and specificity are expected to advance detailed imaging of distinct cortical brain areas and subcortical structures. One target region of particular importance to applications in psychiatry and psychology is the amygdala. However, ultra-high field magnetic resonance imaging of these ventral brain regions is a challenging endeavor that requires particular methodological considerations. Ventral brain areas are particularly prone to signal losses arising from strong magnetic field inhomogeneities along susceptibility borders. In addition, physiological artifacts from respiration and cardiac action cause considerable fluctuations in the MR signal. Here we show that, despite these challenges, fMRI data from the amygdala may be obtained with high temporal and spatial resolution combined with increased signal-to-noise ratio. Maps of neural activation during a facial emotion discrimination paradigm at 7 T are presented and clearly show the gain in percental signal change compared to 3 T results, demonstrating the potential benefits of ultra-high field functional MR imaging also in ventral brain areas

  17. Ophthalmic examination in early diagnosis of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Xin Li

    2018-02-01

    Full Text Available Alzheimer's disease is a progressive neurodegenerative disorder causing irreversible deterioration in memory and loss of self-care ability, which is seriously affecting the quality of life. There is no cure for Alzheimer's disease. Medication only can control the progression of the disease. Early diagnosis and control of disease progress is of great significance in improving the quality of life of the patients and reducing the burden of family and society. Ophthalmic examination is seen as a window which can “see” brain directly, and some changes in the eye can reflect the changes of the brain most directly. This paper reviews the ophthalmic examination of Alzheimer's disease, including optical coherence tomography(OCT, visual field, contrast sensitivity and eye movements, et al. We hope to provide a new idea for the early diagnosis of Alzheimer's disease.

  18. Postoperative pain in complex ophthalmic surgical procedures: comparing practice with guidelines.

    Science.gov (United States)

    Lesin, Mladen; Sundov, Zeljka Duplancic; Jukic, Marko; Puljak, Livia

    2014-06-01

    To analyze the management of postoperative pain after complex ophthalmic surgery and to compare it to the guidelines. A retrospective study. University Hospital Split, Croatia. Patients (N = 447) who underwent complex ophthalmic surgical procedures from 2008 to 2012. The following data were extracted from patient medical records: age, gender, type and dosage of premedication, preoperative patient's physical status, type of procedure, duration of procedure-surgical and anesthesia time, type and dosage of anesthesia, the type and dosage of postoperative analgesia for each postoperative day. None of the patients had information about pain intensity in their records. There were 90% patients who did not receive any medication the night before surgery, 54% did not receive any premedication immediately before surgery, 19% did not receive any pain medication after the surgery in the operating room and 46% of patients did not receive any analgesics after being released to the ophthalmology department. Among those who received analgesia after surgery, 98% received only one dose of an analgesic, and 93% of patients received analgesia only on the day of the surgery. Furthermore, patients were returned to the department immediately after surgery, without intensive monitoring. During the analyzed five years there were no educational session organized by anesthesiologist to the ophthalmic surgeons. Postoperative pain management and perioperative care of patients undergoing major ophthalmic surgery indicates lack of attention towards pain intensity and postoperative analgesia. Appropriate interventions should be employed to improve postoperative pain management, to facilitate patient recovery. Wiley Periodicals, Inc.

  19. Food contaminant analysis at ultra-high mass resolution: application of hybrid linear ion trap - orbitrap mass spectrometry for the determination of the polyether toxins, azaspiracids, in shellfish.

    LENUS (Irish Health Repository)

    2010-10-30

    The biotoxins, azaspiracids (AZAs), from marine phytoplankton accumulate in shellfish and affect human health by causing severe gastrointestinal disturbance, diarrhea, nausea and vomiting. Specific and sensitive methods have been developed and validated for the determination of the most commonly occurring azaspiracid analogs. An LTQ Orbitrap mass spectrometer is a hybrid instrument that combines linear ion trap (LIT) mass spectrometry (MS) with high-resolution Fourier transform (FT) MS and this was exploited to perform simultaneous ultra-high-resolution full-scan MS analysis and collision-induced dissociation (CID) tandem mass spectrometry (MS\\/MS). Using the highest mass resolution setting (100,000 FWHM) in full-scan mode, the methodology was validated for the determination of six AZAs in mussel (Mytilus galloprovincialis) tissue extracts. Ultra-high mass resolution, together with a narrow mass tolerance window of ±2 mDa, dramatically improved detection sensitivity. In addition to employing chromatographic resolution to distinguish between the isomeric azaspiracid analogs, AZA1\\/AZA6 and AZA4\\/AZA5, higher energy collisionally induced dissociation (HCD) fragmentation on selected precursor ions were performed in parallel with full-scan FTMS. Using HCD MS\\/MS, most precursor and product ion masses were determined within 1 ppm of the theoretical m\\/z values throughout the mass spectral range and this enhanced the reliability of analyte identity.For the analysis of mussels (M. galloprovincialis), the method limit of quantitation (LOQ) was 0.010 µg\\/g using full-scan FTMS and this was comparable with the LOQ (0.007 µg\\/g) using CID MS\\/MS. The repeatability data were; intra-day RSD% (1.8-4.4%; n = 6) and inter-day RSD% (4.7-8.6%; n = 3). Application of these methods to the analysis of mussels (M. edulis) that were naturally contaminated with azaspiracids, using high-resolution full-scan Orbitrap MS and low-resolution CID MS\\/MS, produced

  20. Bayesian Multiresolution Variable Selection for Ultra-High Dimensional Neuroimaging Data.

    Science.gov (United States)

    Zhao, Yize; Kang, Jian; Long, Qi

    2018-01-01

    Ultra-high dimensional variable selection has become increasingly important in analysis of neuroimaging data. For example, in the Autism Brain Imaging Data Exchange (ABIDE) study, neuroscientists are interested in identifying important biomarkers for early detection of the autism spectrum disorder (ASD) using high resolution brain images that include hundreds of thousands voxels. However, most existing methods are not feasible for solving this problem due to their extensive computational costs. In this work, we propose a novel multiresolution variable selection procedure under a Bayesian probit regression framework. It recursively uses posterior samples for coarser-scale variable selection to guide the posterior inference on finer-scale variable selection, leading to very efficient Markov chain Monte Carlo (MCMC) algorithms. The proposed algorithms are computationally feasible for ultra-high dimensional data. Also, our model incorporates two levels of structural information into variable selection using Ising priors: the spatial dependence between voxels and the functional connectivity between anatomical brain regions. Applied to the resting state functional magnetic resonance imaging (R-fMRI) data in the ABIDE study, our methods identify voxel-level imaging biomarkers highly predictive of the ASD, which are biologically meaningful and interpretable. Extensive simulations also show that our methods achieve better performance in variable selection compared to existing methods.

  1. Comparison of the effects of ophthalmic solutions on human corneal epithelial cells using fluorescent dyes.

    Science.gov (United States)

    Xu, Manlong; Sivak, Jacob G; McCanna, David J

    2013-11-01

    To investigate the effect of differently preserved ophthalmic solutions on the viability and barrier function of human corneal epithelial cells (HCEC) using fluorescent dyes. HCEC monolayers were exposed to the ophthalmic solutions containing benzalkonium chloride (BAK), edetate disodium, polyquad, stabilized oxychloro complex (Purite), sodium perborate, or sorbic acid for 5 min, 15 min, and 1 h. At 24 h after exposure, the cultures were assessed for metabolic activity using alamarBlue. The enzyme activity, membrane integrity, and apoptosis were evaluated using confocal microscopy. Barrier function was assessed using sodium fluorescein. The metabolic assay showed that the BAK-preserved ophthalmic solutions significantly reduced cell viability after a 5-min exposure compared to the phosphate buffered saline treated control (POphthalmic solutions with new preservatives had varying time-dependent adverse effects on cell viability, and the preservative-free solution had the least effect on HCEC. Sodium fluorescein permeability showed that HCEC monolayers treated with BAK-preserved solutions were more permeable to sodium fluorescein than those treated by the other ophthalmic solutions (Psolutions had greater adverse effects on metabolic activity, enzyme activity, membrane integrity, cell viability, and barrier function than the solutions that were not preserved with BAK. Our study suggests that BAK-free especially, preservative-free ophthalmic solutions are safer alternatives to BAK-preserved ones.

  2. The Dynamic Range of Ultra-High Resolution Cryogenic Gamma-ray Spectrometers

    International Nuclear Information System (INIS)

    Ali, S; Terracol, S F; Drury, O B; Friedrich, S

    2005-01-01

    We are developing high-resolution cryogenic gamma-ray spectrometers for nuclear science and non-proliferation applications. The gamma-ray detectors are composed of a bulk superconducting Sn foil absorber attached to multilayer Mo/Cu transition-edge sensors (TES). The energy resolution achieved with a 1 x 1 x 0.25 mm 3 Sn absorber is 50 -90eV for γ-rays up to 100 keV and it decreases for large absorber sizes. We discuss the trade-offs between energy resolution and dynamic range, as well as development of TES arrays for higher count rates and better sensitivity

  3. Shortcomings of the industrial quality assurance of 106Ru ophthalmic plaques

    International Nuclear Information System (INIS)

    Kaulich, T.W.; Nuesslin, F.; Fluehs, D.; Haug, T.; Bamberg, M.

    2001-01-01

    Background: Beta emitting 106 Ru applicators manufactured by Bebig GmbH (Berlin, Germany) are widely used to treat intraocular tumors. The applicators are fixed to the bulbus and removed after several days. The following therapy relevant defects have been detected by an internal clinical acceptance test: risk of leakage and inconsistent dose-rate specifications by the manufacturer. In the meantime, components of the internal clinical acceptance test have been adopted successfully by the manufacturer of the 106 Ru ophthalmic plaques. Material and Method: 106 Ru ophthalmic plaques were tested with the following internal clinical acceptance tests: visual inspection, surface contamination, leakage, and dose-rate verification. The surface contamination test consists of a wet wipe test at moderate pressure. For the leakage test of the 106 Ru ophthalmic plaques a clinically relevant scenario was developed in which the contact of the applicator with human tissue is simulated. In the course of it the applicator is inserted into Ringer's solution for several days. The certified energy dose-rate statements of the manufacturer are examined with a 1 mm 3 plastic scintillator for consistency. (orig.) [de

  4. Classification of Ultra-High Resolution Orthophotos Combined with DSM Using a Dual Morphological Top Hat Profile

    Directory of Open Access Journals (Sweden)

    Qian Zhang

    2015-12-01

    Full Text Available New aerial sensors and platforms (e.g., unmanned aerial vehicles (UAVs are capable of providing ultra-high resolution remote sensing data (less than a 30-cm ground sampling distance (GSD. This type of data is an important source for interpreting sub-building level objects; however, it has not yet been explored. The large-scale differences of urban objects, the high spectral variability and the large perspective effect bring difficulties to the design of descriptive features. Therefore, features representing the spatial information of the objects are essential for dealing with the spectral ambiguity. In this paper, we proposed a dual morphology top-hat profile (DMTHP using both morphology reconstruction and erosion with different granularities. Due to the high dimensional feature space, we have proposed an adaptive scale selection procedure to reduce the feature dimension according to the training samples. The DMTHP is extracted from both images and Digital Surface Models (DSM to obtain complimentary information. The random forest classifier is used to classify the features hierarchically. Quantitative experimental results on aerial images with 9-cm and UAV images with 5-cm GSD are performed. Under our experiments, improvements of 10% and 2% in overall accuracy are obtained in comparison with the well-known differential morphological profile (DMP feature, and superior performance is observed over other tested features. Large format data with 20,000 × 20,000 pixels are used to perform a qualitative experiment using the proposed method, which shows its promising potential. The experiments also demonstrate that the DSM information has greatly enhanced the classification accuracy. In the best case in our experiment, it gives rise to a classification accuracy from 63.93% (spectral information only to 94.48% (the proposed method.

  5. Physical properties of shallow landslides and their role in landscape evolution investigated with ultrahigh-resolution lidar data and aerial imagery

    Science.gov (United States)

    Nelson, M. D.; Bryk, A. B.; Fauria, K.; Huang, M. H.; Dietrich, W. E.

    2017-12-01

    Shallow landslides are often a primary method of sediment transport and a dominant process of hillslope evolution in steep, soil-mantled landscapes. However, detailed studies of single landslides can be difficult to generalize across a landscape and watershed-scale analyses using coarse-resolution digital elevation models often fail to capture the detail necessary to understand the mechanics of individual slides. During February 2017, an intense rainfall event generated over 400 shallow landslides within a 13 km2 field site in Colusa County, Northern California, providing a unique opportunity to investigate how landsliding affects landscape morphology at multiple scales. The hilly grass and oak woodland site is underlain by Great Valley Sequence shale, sandstone, and conglomerate turbidites uniformly dipping 50° east, with ridgelines and valleys following bedding orientation. Here we present results from ultrahigh-resolution ( 100 points per square meter) airborne lidar data and aerial imagery collected directly after the event, as well as high-resolution airborne lidar data collected in 2015 and preliminary findings from field surveys. Of the 136 landslides surveyed so far, the failure surface was at the soil-weathered bedrock boundary in 85%. Only 69% of the landslides traveled down hillslopes and reached active channels, and of these, 37% transformed into debris flows that scoured channel pathways to bedrock. These small landslides have a median width of 3.2 m and average failure depth of 0.4 m. Landslides occurred at a median pre-failure ground surface slope of 35°, and only 56% occurred in convergent or weakly convergent areas. This comprehensive before and after dataset is being used as a rigorous test of shallow landslide models that predict landslide size and location, as well as a lens to investigate patterns in slope stability or failure with across the landscape. After multiple years of fieldwork at this study site where small landslide scars suggested

  6. Towards 10 meV resolution: The design of an ultrahigh resolution soft X-ray RIXS spectrometer.

    Science.gov (United States)

    Dvorak, Joseph; Jarrige, Ignace; Bisogni, Valentina; Coburn, Scott; Leonhardt, William

    2016-11-01

    We present the optical design of the Centurion soft X-ray resonant inelastic X-ray scattering (RIXS) spectrometer to be located on the SIX beamline at NSLS-II. The spectrometer is designed to reach a resolving power of 100 000 at 1000 eV at its best resolution. It is also designed to have continuously variable 2θ motion over a range of 112° using a custom triple rotating flange. We have analyzed several possible spectrometer designs capable of reaching the target resolution. After careful analysis, we have adopted a Hettrick-Underwood spectrometer design, with an additional plane mirror to maintain a fixed direction for the outgoing beam. The spectrometer can cancel defocus and coma aberrations at all energies, has an erect focal plane, and minimizes mechanical motions of the detector. When the beamline resolution is accounted for, the net spectral resolution will be 14 meV at 1000 eV. This will open up many low energy excitations to study and will expand greatly the power of soft X-ray RIXS.

  7. Towards 10 meV resolution: The design of an ultrahigh resolution soft X-ray RIXS spectrometer

    Science.gov (United States)

    Dvorak, Joseph; Jarrige, Ignace; Bisogni, Valentina; Coburn, Scott; Leonhardt, William

    2016-11-01

    We present the optical design of the Centurion soft X-ray resonant inelastic X-ray scattering (RIXS) spectrometer to be located on the SIX beamline at NSLS-II. The spectrometer is designed to reach a resolving power of 100 000 at 1000 eV at its best resolution. It is also designed to have continuously variable 2θ motion over a range of 112° using a custom triple rotating flange. We have analyzed several possible spectrometer designs capable of reaching the target resolution. After careful analysis, we have adopted a Hettrick-Underwood spectrometer design, with an additional plane mirror to maintain a fixed direction for the outgoing beam. The spectrometer can cancel defocus and coma aberrations at all energies, has an erect focal plane, and minimizes mechanical motions of the detector. When the beamline resolution is accounted for, the net spectral resolution will be 14 meV at 1000 eV. This will open up many low energy excitations to study and will expand greatly the power of soft X-ray RIXS.

  8. Audit of patients' awareness of ophthalmic diagnoses.

    Science.gov (United States)

    Sudesh, S; Downes, S M; McDonnell, P J

    1993-09-01

    Providing information to patients about their medical condition and treatment options is important in medical management. To assess patients' knowledge of their ocular disease, prognosis, and treatment a questionnaire based survey was performed. 219 patients selected by random systematic sampling during six months from patients attending general ophthalmic clinics in Selly Oak Hospital, Birmingham, were questioned and 217 questionnaires were analysed. The findings showed that patients' knowledge of their diagnosis depended on their condition: patients with common conditions such as glaucoma and cataract had a better understanding of their condition, its treatment, and prognosis compared with patients with rarer conditions such as retinal detachment or patients with multiple diagnoses. In all, 152 patients (70%) wanted more information about their condition; 49 (23%) did not (although 12 (25%) had attempted to obtain information); and 16 (7%) were undecided. In view of the few patients with a precise understanding of their ophthalmic diagnosis and prognosis and the majority's wish for access to further information, that access needs improvement and different modes of disseminating the information should be implemented.

  9. Pulsed UV laser technologies for ophthalmic surgery

    International Nuclear Information System (INIS)

    Razhev, A M; Bagayev, S N; Churkin, D S; Kargapol’tsev, E S; Chernykh, V V; Iskakov, I A; Ermakova, O V

    2017-01-01

    The paper provides an overview of the results of multiyear joint researches of team of collaborators of Institute of Laser Physics SB RAS together with NF IRTC “Eye Microsurgery” for the period from 1988 to the present, in which were first proposed and experimentally realized laser medical technologies for correction of refractive errors of known today as LASIK, the treatment of ophthalmic herpes and open-angle glaucoma. It is proposed to carry out operations for the correction of refractive errors the use of UV excimer KrCl laser with a wavelength of 222 nm. The same laser emission is the most suitable for the treatment of ophthalmic herpes, because it has a high clinical effect, combined with many years of absence of recrudescence. A minimally invasive technique of glaucoma operations using excimer XeCl laser (λ=308 nm) is developed. Its wavelength allows perform all stages of glaucoma operations, while the laser head itself has high stability and lifetime, will significantly reduce operating costs, compared with other types of lasers. (paper)

  10. Pediatric ophthalmic indications for examination under anesthesia in ...

    African Journals Online (AJOL)

    Objective: To determine the ophthalmic indications and challenges for pediatric ocular examination under anesthesia (EUA). Methods: The surgical register and patients' records of children who underwent EUA between 1990 and 2007 were examined to document patients' bio data, diagnoses and details of procedures and ...

  11. A new human eye model for ophthalmic brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Yoriyaz, H.; Sanchez, A.; Dos Santos, A.

    2005-01-01

    The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures that were not treated in previous works, allowing dose determination in different regions of the eye for a more adequate clinical analysis. Dose calculations were determined with the MCNP-4C Monte Carlo particle transport code running n parallel environment using PVM. The Amersham CKA4 ophthalmic applicator has been chosen and the depth dose distribution has been determined and compared to those provide by the manufacturer. The results have shown excellent agreement. Besides, absorbed dose values due to both 125 I seeds and 60 Co plaques were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses. (authors)

  12. Research on compression performance of ultrahigh-definition videos

    Science.gov (United States)

    Li, Xiangqun; He, Xiaohai; Qing, Linbo; Tao, Qingchuan; Wu, Di

    2017-11-01

    With the popularization of high-definition (HD) images and videos (1920×1080 pixels and above), there are even 4K (3840×2160) television signals and 8 K (8192×4320) ultrahigh-definition videos. The demand for HD images and videos is increasing continuously, along with the increasing data volume. The storage and transmission cannot be properly solved only by virtue of the expansion capacity of hard disks and the update and improvement of transmission devices. Based on the full use of the coding standard high-efficiency video coding (HEVC), super-resolution reconstruction technology, and the correlation between the intra- and the interprediction, we first put forward a "division-compensation"-based strategy to further improve the compression performance of a single image and frame I. Then, by making use of the above thought and HEVC encoder and decoder, a video compression coding frame is designed. HEVC is used inside the frame. Last, with the super-resolution reconstruction technology, the reconstructed video quality is further improved. The experiment shows that by the proposed compression method for a single image (frame I) and video sequence here, the performance is superior to that of HEVC in a low bit rate environment.

  13. Highly informative multiclass profiling of lipids by ultra-high performance liquid chromatography - Low resolution (quadrupole) mass spectrometry by using electrospray ionization and atmospheric pressure chemical ionization interfaces.

    Science.gov (United States)

    Beccaria, Marco; Inferrera, Veronica; Rigano, Francesca; Gorynski, Krzysztof; Purcaro, Giorgia; Pawliszyn, Janusz; Dugo, Paola; Mondello, Luigi

    2017-08-04

    A simple, fast, and versatile method, using an ultra-high performance liquid chromatography system coupled with a low resolution (single quadrupole) mass spectrometer was optimized to perform multiclass lipid profiling of human plasma. Particular attention was made to develop a method suitable for both electrospray ionization and atmospheric pressure chemical ionization interfaces (sequentially in positive- and negative-ion mode), without any modification of the chromatographic conditions (mobile phase, flow-rate, gradient, etc.). Emphasis was given to the extrapolation of the structural information based on the fragmentation pattern obtained using atmospheric pressure chemical ionization interface, under each different ionization condition, highlighting the complementary information obtained using the electrospray ionization interface, of support for related molecule ions identification. Furthermore, mass spectra of phosphatidylserine and phosphatidylinositol obtained using the atmospheric pressure chemical ionization interface are reported and discussed for the first time. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Cytotoxicity of ophthalmic solutions with and without preservatives to human corneal endothelial cells, epithelial cells and conjunctival epithelial cells.

    Science.gov (United States)

    Ayaki, Masahiko; Yaguchi, Shigeo; Iwasawa, Atsuo; Koide, Ryohei

    2008-08-01

    The cytotoxicity of a range of commercial ophthalmic solutions in the presence and absence of preservatives was assessed in human corneal endothelial cells (HCECs), corneal epithelia and conjunctival epithelia using in vitro techniques. Cell survival was measured using the WST-1 assay for endothelial cells and the MTT assay for epithelial cells. Commercially available timolol, carteolol, cromoglicate, diclofenac, bromfenac and hyaluronic acid ophthalmic solutions were assessed for cytotoxicity in the presence and absence of preservatives. The preservatives benzalkonium, chlorobutanol and polysorbate were also tested. The survival of cells exposed to test ophthalmic solutions was expressed as a percentage of cell survival in the control solution (distilled water added to media) after 48 h exposure. HCEC survival was 20-30% in ophthalmic solutions diluted 10-fold. The survival of HCEC was significantly greater in all solutions in the absence of preservative than in the presence of preservative. The survival of corneal and conjunctival epithelia was consistent with that of HCECs for all test ophthalmic solutions. The preservatives polysorbate and benzalkonium were highly cytotoxic with cell survival decreasing to 20% at the concentration estimated in commercial ophthalmic solutions. By comparison, the survival of cells exposed to chlorobutanol was 80% or greater. The cytotoxicity of ophthalmic solutions to HCEC, corneal epithelia and conjunctival epithelia decreased in the absence of preservative.

  15. Financial return-on-investment of ophthalmic interventions: a new paradigm.

    Science.gov (United States)

    Brown, Melissa M; Brown, Gary C; Lieske, Heidi B; Lieske, P Alexander

    2014-05-01

    Although the patient value gain (improvement in quality-of-life and/or length-of-life) has been highlighted in Value-based Medicine cost-utility analyses, the financial value gain associated with healthcare interventions has received less emphasis. It is important for professional healthcare providers to realize their interventions often confer a large financial return-on-investment (ROI) to society. The societal costs associated with vitreoretinal and other ophthalmic interventions include: direct ophthalmic medical costs expended (hospital, physician, drug, diagnostic testing and so forth), direct medical costs saved (decreased costs for depression, injury, skilled nursing facility, nursing home and others), direct nonmedical costs saved (decreased costs for caregivers, transportation, residence costs, moving costs, and others), and indirect medical costs saved (improving employment incidence and wages). The financial ROI for direct ophthalmic medical costs expended for ranibizumab therapy for neovascular age-related macular degeneration is 450%, whereas that for cataract surgery is 4500% and for medical open-angle glaucoma therapy is 4000%. Many costs gained add to the Gross Domestic Product and increase the wealth of the nation. Many vitreoretinal and other ophthalmologic interventions confer considerable patient value, but also result in a large financial ROI to society. This financial ROI increases the wealth of the nation.

  16. Advanced Photon Source accelerator ultrahigh vacuum guide

    International Nuclear Information System (INIS)

    Liu, C.; Noonan, J.

    1994-03-01

    In this document the authors summarize the following: (1) an overview of basic concepts of ultrahigh vacuum needed for the APS project, (2) a description of vacuum design and calculations for major parts of APS, including linac, linac waveguide, low energy undulator test line, positron accumulator ring (PAR), booster synchrotron ring, storage ring, and insertion devices, and (3) cleaning procedures of ultrahigh vacuum (UHV) components presently used at APS

  17. Evaluation of the cytotoxic effects of ophthalmic solutions containing benzalkonium chloride on corneal epithelium using an organotypic 3-D model.

    Science.gov (United States)

    Khoh-Reiter, Su; Jessen, Bart A

    2009-07-28

    Benzalkonium chloride (BAC) is a common preservative used in ophthalmic solutions. The aim of this study was to compare the cytotoxic effects of BAC-containing ophthalmic solutions with a BAC-free ophthalmic solution using an organotypic 3-dimensional (3-D) corneal epithelial model and to determine the effects of latanoprost ophthalmic solution and its BAC-containing vehicle on corneal thickness in a monkey model. The cytotoxicity of commercially available BAC-containing ophthalmic formulations of latanoprost (0.02% BAC) and olopatadine (0.01% BAC) was compared to that of BAC-free travoprost and saline in a corneal organotypic 3-D model using incubation times of 10 and 25 minutes. To compare the extent of differentiation of 3-D corneal cultures to monolayer transformed human corneal epithelial (HCE-T) cell cultures, expression levels (mRNA and protein) of the corneal markers epidermal growth factor receptor, transglutaminase 1 and involucrin were quantified. Finally, latanoprost ophthalmic solution or its vehicle was administered at suprapharmacologic doses (two 30 microL drops twice daily in 1 eye for 1 year) in monkey eyes, and corneal pachymetry was performed at baseline and at weeks 4, 13, 26 and 52. In the 3-D corneal epithelial culture assays, there were no significant differences in cytotoxicity between the BAC-containing latanoprost and olopatadine ophthalmic solutions and BAC-free travoprost ophthalmic solution at either the 10- or 25-minute time points. The 3-D cultures expressed higher levels of corneal epithelial markers than the HCE-T monolayers, indicating a greater degree of differentiation. There were no significant differences between the corneal thickness of monkey eyes treated with latanoprost ophthalmic solution or its vehicle (both containing 0.02% BAC) and untreated eyes. The lack of cytotoxicity demonstrated in 3-D corneal cultures and in monkey studies suggests that the levels of BAC contained in ophthalmic solutions are not likely to cause

  18. Evaluation of the cytotoxic effects of ophthalmic solutions containing benzalkonium chloride on corneal epithelium using an organotypic 3-D model

    Directory of Open Access Journals (Sweden)

    Jessen Bart A

    2009-07-01

    Full Text Available Abstract Background Benzalkonium chloride (BAC is a common preservative used in ophthalmic solutions. The aim of this study was to compare the cytotoxic effects of BAC-containing ophthalmic solutions with a BAC-free ophthalmic solution using an organotypic 3-dimensional (3-D corneal epithelial model and to determine the effects of latanoprost ophthalmic solution and its BAC-containing vehicle on corneal thickness in a monkey model. Methods The cytotoxicity of commercially available BAC-containing ophthalmic formulations of latanoprost (0.02% BAC and olopatadine (0.01% BAC was compared to that of BAC-free travoprost and saline in a corneal organotypic 3-D model using incubation times of 10 and 25 minutes. To compare the extent of differentiation of 3-D corneal cultures to monolayer transformed human corneal epithelial (HCE-T cell cultures, expression levels (mRNA and protein of the corneal markers epidermal growth factor receptor, transglutaminase 1 and involucrin were quantified. Finally, latanoprost ophthalmic solution or its vehicle was administered at suprapharmacologic doses (two 30 μL drops twice daily in 1 eye for 1 year in monkey eyes, and corneal pachymetry was performed at baseline and at weeks 4, 13, 26 and 52. Results In the 3-D corneal epithelial culture assays, there were no significant differences in cytotoxicity between the BAC-containing latanoprost and olopatadine ophthalmic solutions and BAC-free travoprost ophthalmic solution at either the 10- or 25-minute time points. The 3-D cultures expressed higher levels of corneal epithelial markers than the HCE-T monolayers, indicating a greater degree of differentiation. There were no significant differences between the corneal thickness of monkey eyes treated with latanoprost ophthalmic solution or its vehicle (both containing 0.02% BAC and untreated eyes. Conclusion The lack of cytotoxicity demonstrated in 3-D corneal cultures and in monkey studies suggests that the levels of BAC

  19. 21 CFR 524.390a - Chloramphenicol ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS... treatment for 48 hours (2 days) after eye appears normal. Therapy for cats should not exceed 7 days... therapy should be considered. When infection may be cause of disease, especially in purulent or catarrhal...

  20. Ultrahigh-pressure transitions in solid hydrogen

    International Nuclear Information System (INIS)

    Mao, H.; Hemley, R.J.

    1994-01-01

    During the past five years, major progress has been made in the experimental study of solid hydrogen at ultrahigh pressures as a result of developments in diamond-cell technology. Pressures at which metallization has been predicted to occur have been reached (250--300 Gigapascals). Detailed studies of the dynamic, structural, and electronic properties of dense hydrogen reveal a system unexpectedly rich in physical phenomena, exhibiting a variety of transitions at ultrahigh pressures. This colloquium explores the study of dense hydrogen as an archetypal problem in condensed-matter physics

  1. Doppler sonographic evaluation of ophthalmic arterial flow pattern in hypertensive patients

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Young Goo

    1994-01-01

    To compare the Doppler velocity waveform pattern of ophthalmic artery of hypertensive patients with that of normotensive subjects. Doppler velocity waveform was obtained from ophthalmic artery in 45 hypertensive patients and 60 normotensive subjects. Both hypertensives and normotensive subjects were classified according to age into those younger than and those older than 45 years. Doppler indices(pulsatility index(PI), resistance index(RI), the first systolic peak/the second systolic peak(S1/S2), the first systolic peak/diastolic peak(S1/D)) measured in hypertensive patients were compared with normotensive subjects. Among the various doppler indices, only S1/S2 showed significant difference(P < 0.05) between the hypertensive patients and normotensive subjects younger than 45 years. Doppler velocity waveform of hypertensive patients older than 45 years showed no significant difference from that of normotensive subjects with corresponding age. Doppler velocity waveform of ophthalmic artery in hypertensive patients younger than 45 years shows pattern with S2 higher than that of normotensive subjects. High S2 component(reflective-wave) may represent increased vascular impedance due to vasococonstriction of retinal arterioles in hypertensive patients

  2. Integration of ultra-high field MRI and histology for connectome based research of brain disorders

    Directory of Open Access Journals (Sweden)

    Shan eYang

    2013-09-01

    Full Text Available Ultra-high field magnetic resonance imaging (MRI became increasingly relevant for in vivo neuroscientific research because of improved spatial resolutions. However, this is still the unchallenged domain of histological studies, which long played an important role in the investigation of neuropsychiatric disorders. While the field of biological psychiatry strongly advanced on macroscopic levels, current developments are rediscovering the richness of immunohistological information when attempting a multi-level systematic approach to brain function and dysfunction. For most studies, histology sections lost information on three-dimensional reconstructions. Translating histological sections to 3D-volumes would thus not only allow for multi-stain and multi-subject alignment in post mortem data, but also provide a crucial step in big data initiatives involving the network analyses currently performed with in vivo MRI. We therefore investigated potential pitfalls during integration of MR and histological information where no additional blockface information is available. We demonstrated that strengths and requirements from both methods seem to be ideally merged at a spatial resolution of 200 μm. However, the success of this approach is heavily dependent on choices of hardware, sequence and reconstruction. We provide a fully automated pipeline that optimizes histological 3D reconstructions, providing a potentially powerful solution not only for primary human post mortem research institutions in neuropsychiatric research, but also to help alleviate the massive workloads in neuroanatomical atlas initiatives. We further demonstrate (for the first time the feasibility and quality of ultra-high spatial resolution (150 µm isotopic imaging of the entire human brain MRI at 7T, offering new opportunities for analyses on MR-derived information.

  3. New Zealand health reforms: effect on ophthalmic practice.

    Science.gov (United States)

    Raynel, S; Reynolds, H

    1999-01-01

    Are specialized ophthalmic units with inpatient facilities going to disappear in the New Zealand public health system? We have entered the era of cost containment, business methodologies, bench marking, day case surgery, and technologic advances. The dilemma for nursing is maintenance of a skill base with dwindling clinical practice areas.

  4. Gatifloxacin Ophthalmic Solution for Treatment of Bacterial Conjunctivitis: Safety, Efficacy and Patient Perspective

    OpenAIRE

    Clyde Schultz

    2012-01-01

    Gatifloxacin is a fourth generation fluroquinolone antibiotic that has been prescribed for systemic use. However, the drug which was developed by Kyorin (Japan) was linked to toxic reactions and death and was banned in the United States and Canada for use as an oral dosage form. It continues to be used as a topical application for ophthalmic conditions as the systemic toxicity seen when taking the drug orally has not been observed with ophthalmic use. The available data indicate that ocular u...

  5. Modal analysis of the ultrahigh finesse Haroche QED cavity

    Science.gov (United States)

    Marsic, Nicolas; De Gersem, Herbert; Demésy, Guillaume; Nicolet, André; Geuzaine, Christophe

    2018-04-01

    In this paper, we study a high-order finite element approach to simulate an ultrahigh finesse Fabry–Pérot superconducting open resonator for cavity quantum electrodynamics. Because of its high quality factor, finding a numerically converged value of the damping time requires an extremely high spatial resolution. Therefore, the use of high-order simulation techniques appears appropriate. This paper considers idealized mirrors (no surface roughness and perfect geometry, just to cite a few hypotheses), and shows that under these assumptions, a damping time much higher than what is available in experimental measurements could be achieved. In addition, this work shows that both high-order discretizations of the governing equations and high-order representations of the curved geometry are mandatory for the computation of the damping time of such cavities.

  6. Pushing the limits of signal resolution to make coupling measurement easier.

    Science.gov (United States)

    Herbert Pucheta, José Enrique; Pitoux, Daisy; Grison, Claire M; Robin, Sylvie; Merlet, Denis; Aitken, David J; Giraud, Nicolas; Farjon, Jonathan

    2015-05-07

    Probing scalar couplings are essential for structural elucidation in molecular (bio)chemistry. While the measurement of JHH couplings is facilitated by SERF experiments, overcrowded signals represent a significant limitation. Here, a new band selective pure shift SERF allows access to δ(1)H and JHH with an ultrahigh spectral resolution.

  7. Ophthalmic Morbidity in School Children in Hilly Areas of Uttarakhand

    Directory of Open Access Journals (Sweden)

    Surekha Kishore

    2014-03-01

    Full Text Available Introduction: School children constitute about one fourth of population of India. Early detection and treatment of various eye diseases helps in avoiding many complications. The magnitude of blindness is 3-4 times greater in developing countries. Very few studies have been conducted in Uttarakhand revealing the ophthalmic morbidity in school children or general population. Hilly areas especially the remote ones face various problems like, poor transportation facilities, distant health facilities, use of traditional methods for treatment, faith healing, customs and belief system, lack of information.  Moreover   water supply, poor personal hygiene and other factors also add up to these problems. Aim: To study the ophthalmic morbidities in school children in 3 schools of Thatyur block. Methodology: It was a cross sectional study. Result: A total of 705 students were enrolled. Permission from school authorities was seeked before the start of study. Schools were visited twice in a week current and preliminary information was taken from the students & teacher regarding education, occupation, income etc. General examination and ophthalmic examination was done with day & torch light along with refraction, with the help of standard Snellen’s chart. Each eye was examined separately. A vision of 6/6 was considered as normal. Near vision was tested with new vision Snellen’s chart at 12-14 inches away from eye.

  8. Ophthalmic Morbidity in School Children in Hilly Areas of Uttarakhand

    Directory of Open Access Journals (Sweden)

    Surekha Kishore

    2014-03-01

    Full Text Available Introduction: School children constitute about one fourth of population of India. Early detection and treatment of various eye diseases helps in avoiding many complications. The magnitude of blindness is 3-4 times greater in developing countries. Very few studies have been conducted in Uttarakhand revealing the ophthalmic morbidity in school children or general population. Hilly areas especially the remote ones face various problems like, poor transportation facilities, distant health facilities, use of traditional methods for treatment, faith healing, customs and belief system, lack of information.  Moreover   water supply, poor personal hygiene and other factors also add up to these problems. Aim: To study the ophthalmic morbidities in school children in 3 schools of Thatyur block. Methodology: It was a cross sectional study. Result: A total of 705 students were enrolled. Permission from school authorities was seeked before the start of study. Schools were visited twice in a week current and preliminary information was taken from the students & teacher regarding education, occupation, income etc. General examination and ophthalmic examination was done with day & torch light along with refraction, with the help of standard Snellen’s chart. Each eye was examined separately. A vision of 6/6 was considered as normal. Near vision was tested with new vision Snellen’s chart at 12-14 inches away from eye.

  9. Re-evaluation of Magnetic Resonance and Computerised Tomographic Imaging in Neuro-Ophthalmic Patients in an Academic Centre

    NARCIS (Netherlands)

    Koekoek, Clarence G. J.; Meiners, Linda C.; Pott, Jan Willem R.

    The aim of the study is to report the frequency of missed diagnoses on magnetic resonance and computerised tomographic imaging in neuro-ophthalmic patients who were referred to an academic ophthalmology department, with apparent normal imaging. The authors included all neuro-ophthalmic patients,

  10. Oxidative-stress detoxification and signalling in cyanobacteria: the crucial glutathione synthesis pathway supports the production of ergothioneine and ophthalmate.

    Science.gov (United States)

    Narainsamy, Kinsley; Farci, Sandrine; Braun, Emilie; Junot, Christophe; Cassier-Chauvat, Corinne; Chauvat, Franck

    2016-04-01

    Using genetics and metabolomics we investigated the synthesis (gshA and gshB genes) and catabolism (ggt) of the conserved antioxidant glutathione in the model cyanobacterium Synechocystis PCC6803. These three genes are crucial to Synechocystis, in agreement with the proposed invention of glutathione by ancient cyanobacteria to protect themselves against the toxicity of oxygen they produced through photosynthesis. Consistent with their indispensability, gshA and gshB also operate in the production of another antioxidant, ergothioneine, as well as of the glutathione analogues ophthalmate and norophthalmate. Furthermore, we show that glutathione, ophthalmate and norophthalmate are accumulated in cells stressed by glucose, and that the two glutathione-dependent glyoxalase enzymes operate in the protection against glucose and its catabolite methylglyoxal. These findings are interesting because ophthalmate and norophthalmate were observed only in mammals so far, where ophthalmate is regarded as a biomarker of glutathione depletion. Instead, our data suggest that ophthalmate and norophthalmate are stress-induced markers of cysteine depletion triggered by its accelerated incorporation into glutathione, to face its increased demand for detoxification purposes. Hence, Synechocystis is an attractive model for the analysis of the role of glutathione, ergothioneine, ophthalmate and norophthalmate, in signalling and detoxification of oxidants and metabolic by-products. © 2015 John Wiley & Sons Ltd.

  11. Study on reactor building structure using ultrahigh strength materials, 1

    International Nuclear Information System (INIS)

    Ishimura, Kikuo; Odajima, Masahiro; Irino, Kazuo; Hashiba, Toshio.

    1991-01-01

    This study was promoted to be aimed at realization of the optimal nuclear reactor building structure of the future. As the first step, the study regarding ultrahigh strength reinforced concrete (abbr. RC) shear wall was selected. As the result of various tests, the application of ultrahigh strength RC shear walls was verified. The tests conducted were relevant to; ultrahigh strength concrete material tests; pure shear tests of RC flat panels; and bending shear tests and its simulation analysis of RC shear walls. (author)

  12. Ophthalmic manifestations of head injury.

    Science.gov (United States)

    Kowal, L

    1992-02-01

    Head injuries are frequently associated with ophthalmic problems. The commonest problems seen in this series of 161 patients with head injury were problems with poor accommodation (16% of patients; 58% of these persisted), convergence (14% of patients; 35% of these persisted), pseudomyopia (19%; 55% persisted) and optic atrophy (26% of the patients; 78% of these were mild and easily missed on routine testing, and 22% were severe). Motility disorders were common, especially cranial nerve palsies. Other less frequent motility disturbances included apparent inferior oblique palsy, comitant esotropia, and exotropia which was often of the convergence insufficiency type.

  13. Profile measurement of a bent neutron mirror using an ultrahigh precision non-contact measurement system with an auto focus laser probe

    International Nuclear Information System (INIS)

    Morita, S; Guo, J; Yamagata, Y; Yamada, N L; Torikai, N; Takeda, S; Furusaka, M

    2016-01-01

    A bent neutron mirror has been considered as one of the best solutions for focusing neutron beams from the viewpoint of cost-benefit performance. Although the form deviation of the bent profile is expected because of the large spot size, it is difficult to measure due to its geometric limitation. Here, we propose a non-contact measurement system using an auto focus (AF) laser probe on an ultrahigh precision machine tool to precisely evaluate the form deviation of the bent mirror. The AF laser probe is composed of a diode laser, a position sensitive sensor, a charge-coupled device (CCD) camera and a microscope objective lens which is actuated by an electromagnetic motor with 1 nm resolution for position sensing and control. The sensor enables a non-contact profile measurement of a high precision surface without any surface damage in contrast with contact-type ultrahigh precision coordinate measurement machines with ruby styli. In the on-machine measurement system, a personal computer simultaneously acquires a displacement signal from the AF laser probe and 3-axis positional coordinates of the ultrahigh machine tool branched between the linear laser scales and the numerical controller. The acquisition rate of the 4-axis positional data in 1 nm resolution is more than 10 Hz and the simultaneity between the axes is negligible. The profile of a neutron bent mirror was measured from a transparent side using the developed system, and the result proves that the form deviation of the mirror enlarged the the spot size of focused neuron beam. (paper)

  14. High resolution spectroscopy in the microwave and far infrared

    Science.gov (United States)

    Pickett, Herbert M.

    1990-01-01

    High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.

  15. Outpatients flow management and ophthalmic electronic medical records system in university hospital using Yahgee Document View.

    Science.gov (United States)

    Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa

    2010-10-01

    General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.

  16. 21 CFR 524.1484a - Neomycin sulfate ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS...) Severe infections should be supplemented by systemic therapy. (5) Prolonged administration of the drug... bacteria or fungi appear during therapy, appropriate measures should be taken. (6) Federal law restricts...

  17. Management of ocular inflammation and pain following cataract surgery: focus on bromfenac ophthalmic solution

    OpenAIRE

    Cho, Hyung; Wolf, Kenneth J; Wolf, Eric J

    2009-01-01

    Hyung Cho1, Kenneth J Wolf1, Eric J Wolf21Department of Ophthalmology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA; 2Department of Ophthalmology, Edward S. Harkness Eye Institute of Columbia University College of Physicians and Surgeons, New York, NY, USAAbstract: Recently, several new ophthalmic NSAID products have been introduced for commercial use in the United States. The purpose of this review is to briefly overview the ophthalmic NSAIDs currently...

  18. An Ultra-high Resolution Synthetic Precipitation Data for Ungauged Sites

    Science.gov (United States)

    Kim, Hong-Joong; Choi, Kyung-Min; Oh, Jai-Ho

    2018-05-01

    Despite the enormous damage caused by record heavy rainfall, the amount of precipitation in areas without observation points cannot be known precisely. One way to overcome these difficulties is to estimate meteorological data at ungauged sites. In this study, we have used observation data over Seoul city to calculate high-resolution (250-meter resolution) synthetic precipitation over a 10-year (2005-2014) period. Furthermore, three cases are analyzed by evaluating the rainfall intensity and performing statistical analysis over the 10-year period. In the case where the typhoon "Meari" passed to the west coast during 28-30 June 2011, the Pearson correlation coefficient was 0.93 for seven validation points, which implies that the temporal correlation between the observed precipitation and synthetic precipitation was very good. It can be confirmed that the time series of observation and synthetic precipitation in the period almost completely matches the observed rainfall. On June 28-29, 2011, the estimation of 10 to 30 mm h-1 of continuous strong precipitation was correct. In addition, it is shown that the synthetic precipitation closely follows the observed precipitation for all three cases. Statistical analysis of 10 years of data reveals a very high correlation coefficient between synthetic precipitation and observed rainfall (0.86). Thus, synthetic precipitation data show good agreement with the observations. Therefore, the 250-m resolution synthetic precipitation amount calculated in this study is useful as basic data in weather applications, such as urban flood detection.

  19. Longitudinal ophthalmic findings in a child with Helsmoortel-Van der Aa Syndrome

    Directory of Open Access Journals (Sweden)

    Michael J. Gale

    2018-06-01

    Full Text Available Purpose: We present the first detailed ophthalmic description of a child with Helsmoortel-Van der Aa Syndrome (HVDAS, including longitudinal follow-up and analysis. Observations: After extensive workup, a young child with poor visual behavior, hypotonic cerebral palsy, intellectual disability, and global developmental delay was found to have a heterozygous de novo mutation in the ADNP gene and diagnosed with HVDAS. Ophthalmic findings were remarkable for progressive nystagmus, macular pigment mottling, mild foveal hypoplasia with abnormal macular laminations, persistent rod dysfunction with electronegative waveform, and progressive cone degeneration. Conclusions and importance: Patients with HVDAS are known to have abnormal visual behavior due to refractive or cortical impairment. However, we present the first description, to our knowledge, of an association with retinal mal-development and degeneration. Thus, patients with HVDAS should be referred for ophthalmic genetics evaluation, and HVDAS should be on the differential diagnosis for young children with global developmental delay who present with nystagmus, rod and cone dysfunction with electronegative waveform, and relative lack of severe structural degeneration on optical coherence tomography. Keywords: Helsmoortel-Van der Aa Syndrome, HVDAS, Activity-dependent neuroprotective protein, ADNP, Nystagmus, Retinal degeneration, Electronegative waveform, Optical coherence tomography

  20. Propagation of ultrahigh-energy cosmic rays

    Energy Technology Data Exchange (ETDEWEB)

    Stanev, Todor [Bartol Research Institute and Department of Physics and Astronomy, University of Delaware, Newark, DE 19716 (United States)], E-mail: stanev@bartol.udel.edu

    2009-06-15

    We briefly describe the energy loss processes of ultrahigh-energy protons, heavier nuclei and {gamma}-rays in interactions with the universal photon fields of the Universe. We then discuss the modification of the accelerated cosmic-ray energy spectrum in propagation by the energy loss processes and the charged cosmic-ray scattering in the extragalactic magnetic fields. The energy lost by the ultrahigh-energy cosmic rays goes into {gamma}-rays and neutrinos that carry additional information about the sources of highest energy particles. The new experimental results of the HiRes and the Auger collaborations are discussed in view of the predictions from propagation calculations.

  1. Diagnosis, treatment, and outcome of and risk factors for ophthalmic disease in leopard geckos (Eublepharis macularius) at a veterinary teaching hospital: 52 cases (1985-2013).

    Science.gov (United States)

    Wiggans, K Tomo; Sanchez-Migallon Guzman, David; Reilly, Christopher M; Vergneau-Grosset, Claire; Kass, Philip H; Hollingsworth, Steven R

    2018-02-01

    OBJECTIVE To describe diagnosis, treatment, and outcome of and risk factors for ophthalmic disease in leopard geckos (Eublepharis macularius) evaluated at a veterinary teaching hospital. DESIGN Retrospective case series. ANIMALS 112 of 144 (78%) leopard geckos that were evaluated at a veterinary teaching hospital in January 1985 through October 2013 and for which sufficient medical record information was available. PROCEDURES Information from medical records was used to identify leopard geckos with ophthalmic disease, characterize cases, and determine risk factors for the presence of ophthalmic disease. RESULTS Of the 112 leopard geckos, 52 (46%) had ophthalmic disease (mainly corneal or conjunctival disease). Female geckos were less likely to have ophthalmic disease, and there was a positive association between increasing age and ophthalmic disease. Use of a paper towel substrate, absence of any heat source, and lack of vitamin A supplementation were positively associated with a diagnosis of ophthalmic disease. Head dysecdysis was the only concurrent disorder significantly associated with ophthalmic disease. At necropsy, 5 affected leopard geckos had squamous metaplasia of the conjunctivae. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that ophthalmic disease is a common finding in leopard geckos. The cause of ocular surface disease in leopard geckos may be multifactorial, and hypovitaminosis A may be an important risk factor. Although animals receiving supplemental vitamin A were less likely to have ophthalmic disease, further understanding is required regarding the metabolism of and nutritional requirements for vitamin A in leopard geckos.

  2. The international forum of ophthalmic simulation: developing a virtual reality training curriculum for ophthalmology.

    Science.gov (United States)

    Saleh, George M; Lamparter, Julia; Sullivan, Paul M; O'Sullivan, Fiona; Hussain, Badrul; Athanasiadis, Ioannis; Litwin, Andre S; Gillan, Stewart N

    2013-06-01

    To investigate the effect of a structured, supervised, cataract simulation programme on ophthalmic surgeons in their first year of training, and to evaluate the level of skill transfer. Trainees with minimal intraocular and simulator experience in their first year of ophthalmology undertook a structured, sequential, customised, virtual reality (VR) cataract training programme developed through the International Forum of Ophthalmic Simulation. A set of one-handed, bimanual, static and dynamic tasks were evaluated before and after the course and scores obtained. Statistical significance was evaluated with the Wilcoxon sign-rank test. The median precourse score of 101.50/400 (IQR 58.75-145.75) was significantly improved after completing the training programme ((postcourse score: 302/400, range: 266.25-343), p<0.001). While improvement was evident and found to be statistically significant in all parameters, greatest improvements were found for capsulorhexis and antitremor training ((Capsulorhexis: precourse score=0/100, range 0-4.5; postcourse score=81/100, range 13-87.75; p=0.002), (antitremor training: precourse score=0/100, range 0-0; postcourse score=80/100, range 60.25-91.50; p=0.001)). Structured and supervised VR training can offer a significant level of skills transfer to novice ophthalmic surgeons. VR training at the earliest stage of ophthalmic surgical training may, therefore, be of benefit.

  3. High resolution NMR spectroscopy of nanocrystalline proteins at ultra-high magnetic field

    International Nuclear Information System (INIS)

    Sperling, Lindsay J.; Nieuwkoop, Andrew J.; Lipton, Andrew S.; Berthold, Deborah A.; Rienstra, Chad M.

    2010-01-01

    Magic-angle spinning (MAS) solid-state NMR (SSNMR) spectroscopy of uniformly- 13 C, 15 N labeled protein samples provides insight into atomic-resolution chemistry and structure. Data collection efficiency has advanced remarkably in the last decade; however, the study of larger proteins is still challenged by relatively low resolution in comparison to solution NMR. In this study, we present a systematic analysis of SSNMR protein spectra acquired at 11.7, 17.6 and 21.1 Tesla ( 1 H frequencies of 500, 750, and 900 MHz). For two protein systems-GB1, a 6 kDa nanocrystalline protein and DsbA, a 21 kDa nanocrystalline protein-line narrowing is demonstrated in all spectral regions with increasing field. Resolution enhancement is greatest in the aliphatic region, including methine, methylene and methyl sites. The resolution for GB1 increases markedly as a function of field, and for DsbA, resolution in the C-C region increases by 42%, according to the number of peaks that can be uniquely picked and integrated in the 900 MHz spectra when compared to the 500 MHz spectra. Additionally, chemical exchange is uniquely observed in the highest field spectra for at least two isoleucine Cδ1 sites in DsbA. These results further illustrate the benefits of high-field MAS SSNMR spectroscopy for protein structural studies.

  4. Ultrahigh-energy cosmic-ray spectrum

    International Nuclear Information System (INIS)

    Hill, C.T.; Schramm, D.N.

    1985-01-01

    We analyze the evolution of the ultrahigh-energy cosmic-ray spectrum upon traversing the 2.7 0 K microwave background with respect to pion photoproduction, pair-production reactions, and cosmological effects. Our approach employs exact transport equations which manifestly conserve nucleon number and embody the laboratory details of these reactions. A spectrum enhancement appears around 6 x 10 19 eV due to the ''pile-up'' of energy-degraded nucleons, and a ''dip'' occurs around 10 19 eV due to combined effects. Both of these features appear in the observational spectrum. We analyze the resulting neutrino spectrum and the effects of cosmological source distributions. We present a complete model of the ultrahigh-energy spectrum and anisotropy in reasonable agreement with observation and which predicts an observable electron-neutrino spectrum

  5. Microsurgical treatment of carotid-ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms

    Science.gov (United States)

    Wang, Jiantao; Kan, Zhisheng; Wang, Shuo

    2017-01-01

    Abstract Background: The clipping of multiple intracranial aneurysms in 1 stage is uncommon. In this case, we report clipping of an ophthalmic aneurysm associated with multiple anterior and posterior circulation aneurysms via the Dolenc approach. Methods: The main symptoms of the patient are headache, along with nausea and vomiting. The patient's arteriogram revealed a wide-necked aneurysm of the right ophthalmic artery, an irregular aneurysm of the anterior communicating artery, and a basilar artery aneurysm. The surgical intervention for these aneurysms is a challenge because of the complex anatomical relationship with the surrounding structures. The 3 aneurysms, which were not amenable to a single intervention, were successfully clipped in 1 incision. Results: After surgery, the patient reported feeling well. One year after surgery, the patient had no SAH recurrence. Conclusions: Occasionally, surgical treatment was used even for aneurysms of the carotid-ophthalmic artery with aneurysms of anterior communicating artery and basilar artery, which are contraindicated for interventional therapy. PMID:28422878

  6. [Optimization of benzalkonium chloride concentration in 0.0015% tafluprost ophthalmic solution from the points of ocular surface safety and preservative efficacy].

    Science.gov (United States)

    Asada, Hiroyuki; Takaoka-Shichijo, Yuko; Nakamura, Masatsugu; Kimura, Akio

    2010-06-01

    Optimization of benzalkonium chloride (alkyl dimethylbenzylammonium chloride: BAK) concentration as preservative in 0.0015% tafluprost ophthalmic solution (Tapros 0.0015% ophthalmic solution), an anti-glaucoma medicine, was examined from the points of ocular surface safety and preservative efficacy. BAKC(12), which is dodecyl dimethylbenzylammonium chloride, and BAKmix, which is the mixture of dodecyl, tetradecyl and hexadecyl dimethylbenzylammonium chloride were used in this study. The effects of BAKC(12) concentrations and the BAK types, BAKC(12) and BAKmix, in tafluprost ophthalmic solution on ocular surface safety were evaluated using the in vitro SV 40-immobilized human corneal epithelium cell line (HCE-T). Following treatments of Tafluprost ophthalmic solutions with BAKC(12), its concentration dependency was observed on cell viability of HCE-T. The cell viability of HCE-T after treatment of these solutions with 0.001% to 0.003% BAKC(12) for 5 minutes were the same level as that after treatment of the solution without BAK. Tafluprost ophthalmic solution with 0.01% BAKC(12) was safer for the ocular surface than the same solution with 0.01% BAKmix. Preservatives-effectiveness tests of tafluprost ophthalmic solutions with various concentrations of BAKC(12) were performed according to the Japanese Pharmacopoeia (JP), and solutions with more than 0.0005% BAKC(12) conformed to JP criteria. It was concluded that 0.0005% to 0.003% of BAKC(12) in tafluprost ophthalmic solution was optimal, namely, well-balanced from the points of ocular surface safety and preservative efficacy.

  7. Multimodal adaptive optics for depth-enhanced high-resolution ophthalmic imaging

    Science.gov (United States)

    Hammer, Daniel X.; Mujat, Mircea; Iftimia, Nicusor V.; Lue, Niyom; Ferguson, R. Daniel

    2010-02-01

    We developed a multimodal adaptive optics (AO) retinal imager for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related macular degeneration (AMD), and retinitis pigmentosa (RP). The development represents the first ever high performance AO system constructed that combines AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. The SSOCT channel operates at a wavelength of 1 μm for increased penetration and visualization of the choriocapillaris and choroid, sites of major disease activity for DR and wet AMD. The system is designed to operate on a broad clinical population with a dual deformable mirror (DM) configuration that allows simultaneous low- and high-order aberration correction. The system also includes a wide field line scanning ophthalmoscope (LSO) for initial screening, target identification, and global orientation; an integrated retinal tracker (RT) to stabilize the SLO, OCT, and LSO imaging fields in the presence of rotational eye motion; and a high-resolution LCD-based fixation target for presentation to the subject of stimuli and other visual cues. The system was tested in a limited number of human subjects without retinal disease for performance optimization and validation. The system was able to resolve and quantify cone photoreceptors across the macula to within ~0.5 deg (~100-150 μm) of the fovea, image and delineate ten retinal layers, and penetrate to resolve targets deep into the choroid. In addition to instrument hardware development, analysis algorithms were developed for efficient information extraction from clinical imaging sessions, with functionality including automated image registration, photoreceptor counting, strip and montage stitching, and segmentation. The system provides clinicians and researchers with high-resolution, high performance adaptive optics imaging to help

  8. 21 CFR 524.390d - Chloramphenicol-prednisolone ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    .... 017030 in § 510.600(c) of this chapter. (c) Conditions of use. Dogs and cats—(1) Amount. Apply 4 to 6...) Limitations. Therapy for cats should not exceed 7 days, prolonged use in cats may produce blood dyscrasia. As... institute appropriate therapy. All topical ophthalmic preparations containing corticosteroids, with or...

  9. The Use of Flow Diverting Stents to Treat Para-Ophthalmic Aneurysms

    Directory of Open Access Journals (Sweden)

    Pervinder Bhogal

    2017-08-01

    Full Text Available Background and purposeFew publications have dealt exclusively with the use of flow diverter stents for the treatment of para-ophthalmic aneurysms. We sought to determine the efficacy of flow diverting stents (FDSs to treat aneurysms in this specific location.MethodsWe retrospectively reviewed our database of prospectively collected information for all patients treated with flow diversion for an unruptured saccular para-ophthalmic aneurysm between September 2009 and January 2016. The aneurysm fundus size, neck size, number and type of FDS, complications, and follow-up data were recorded.ResultsWe identified 74 patients that matched our inclusion criteria. Of these patients, 18 patients were male (24.3%. The average fundus size was 4.8 mm, 11 aneurysms had previous coil occlusions and 63 were treated solely with flow diversion. At an initial angiographic follow-up (mean avg. 3.2 months, 71.8% of the aneurysms were occluded, and at the last follow-up (mean avg. 31.8 months, 88.9% of aneurysms were occluded. One patient suffered permanent morbidity (1.36% secondary to interruption of the antiplatelet medication and another died (1.36% secondary to in-stent thrombosis that was also due to an interruption in the antiplatelet medication.ConclusionTreatment of saccular para-ophthalmic aneurysms with FDS is feasible and carries a high degree of technical success with low complication rates and excellent rates of aneurysm exclusion.

  10. Gatifloxacin Ophthalmic Solution for Treatment of Bacterial Conjunctivitis: Safety, Efficacy and Patient Perspective

    Directory of Open Access Journals (Sweden)

    Clyde Schultz

    2012-01-01

    Full Text Available Gatifloxacin is a fourth generation fluroquinolone antibiotic that has been prescribed for systemic use. However, the drug which was developed by Kyorin (Japan was linked to toxic reactions and death and was banned in the United States and Canada for use as an oral dosage form. It continues to be used as a topical application for ophthalmic conditions as the systemic toxicity seen when taking the drug orally has not been observed with ophthalmic use. The available data indicate that ocular use of gatifloxacin is safe, and effective against a broad spectrum of bacteria, including intracellular bacteria and anaerobes.

  11. Some problems of physics of ultrahigh energy cosmic rays

    International Nuclear Information System (INIS)

    Isaev, P.S.

    1999-01-01

    Nearest 15-20 years will be years of flourishing of experimental researches into the energy of cosmic rays at > or ∼ 10 15 eV and of new discoveries in the physics of elementary particles of ultrahigh energies. Unsolved problems of modern physics of ultrahigh energy cosmic rays, which are relevant to the problems of elementary particles physics, are reviewed

  12. Stretchers and compressors for ultra-high power laser systems

    Energy Technology Data Exchange (ETDEWEB)

    Yakovlev, I V [Institute of Applied Physics, Russian Academy of Sciences, Nizhnii Novgorod (Russian Federation)

    2014-05-30

    This review is concerned with pulse stretchers and compressors as key components of ultra-high power laser facilities that take advantage of chirped-pulse amplification. The potentialities, characteristics, configurations and methods for the matching and alignment of these devices are examined, with particular attention to the history of the optics of ultra-short, ultra-intense pulses before and after 1985, when the chirped-pulse amplification method was proposed, which drastically changed the view of the feasibility of creating ultra-high power laser sources. The review is intended primarily for young scientists and experts who begin to address the amplification and compression of chirped pulses, experts in laser optics and all who are interested in scientific achievements in the field of ultra-high power laser systems. (review)

  13. Ophthalmic epidemiology in Europe

    DEFF Research Database (Denmark)

    Delcourt, Cécile; Korobelnik, Jean-François; Buitendijk, Gabriëlle H S

    2016-01-01

    The European Eye Epidemiology (E3) consortium is a recently formed consortium of 29 groups from 12 European countries. It already comprises 21 population-based studies and 20 other studies (case-control, cases only, randomized trials), providing ophthalmological data on approximately 170,000 Euro......The European Eye Epidemiology (E3) consortium is a recently formed consortium of 29 groups from 12 European countries. It already comprises 21 population-based studies and 20 other studies (case-control, cases only, randomized trials), providing ophthalmological data on approximately 170......,000 European participants. The aim of the consortium is to promote and sustain collaboration and sharing of data and knowledge in the field of ophthalmic epidemiology in Europe, with particular focus on the harmonization of methods for future research, estimation and projection of frequency and impact...

  14. Long-term ophthalmic health care in Usher syndrome type I from an ICF perspective.

    Science.gov (United States)

    Möller, Kerstin; Eriksson, Kristina; Sadeghi, André M; Möller, Claes; Danermark, Berth

    2009-01-01

    The aim was to explore ophthalmic health care in female patients with Usher Syndrome type I (USH I) over 20 years and to evaluate the relationship between the ophthalmic health care and the health state of the patients from a health perspective. A retrospective study of records from ophthalmology departments (OD) and low vision clinics (LVC) from 1985 to 2004. Assessment of the reports was performed based on the International Classification of Functioning, Disability and Health (ICF). Findings were analysed by manifest content analysis with ICF as a framework and using four themes: health care system, procedure examinations, patient's functioning and disability and procedure actions. The records of nine female patients (aged 25-39 years, 1985) with USH I were selected from the national database of USH. A great number of notes were collected (OD 344 and LVC 566). Procedure examinations were exclusively oriented towards body structure and function. All patients showed aggravated visual impairment over and above the hearing and vestibular impairment. Procedure actions were oriented towards environmental factors. No correlation was found between procedures performed and patient's experience of disability. The high degree of resource allocation was not correlated to the patients' impairment. The study indicates that the ophthalmic health care was characterised by inefficiency. This conclusion is very serious because patients very likely face severe disability and emotional difficulties. ICF is ought to be incorporated in ophthalmic health care strategy to improve the health care.

  15. Self-transcendence trait and its relationship with in vivo serotonin transporter availability in brainstem raphe nuclei: An ultra-high resolution PET-MRI study.

    Science.gov (United States)

    Kim, Jong-Hoon; Son, Young-Don; Kim, Jeong-Hee; Choi, Eun-Jung; Lee, Sang-Yoon; Joo, Yo-Han; Kim, Young-Bo; Cho, Zang-Hee

    2015-12-10

    Self-transcendence is an inherent human personality trait relating to the experience of spiritual aspects of the self. We examined the relationship between self-transcendence and serotonin transporter (SERT) availability in brainstem raphe nuclei, which are collections of five different serotonergic nuclei with rostro-caudal extension, using ultra-high resolution magnetic resonance imaging (MRI) and positron emission tomography (PET) with (11)C-3-amino-4-(2-dimethylaminomethylphenylthio)benzonitrile ([(11)C]DASB) to elucidate potential roles of serotonergic neuronal activities in this personality trait. Sixteen healthy subjects completed 7.0T MRI and High Resolution Research Tomograph (HRRT) PET. The regions of interest (ROIs) included the dorsal raphe nucleus (R1), median raphe nucleus (R2), raphe pontis (R3), and the caudal raphe nuclei (R4 and R5). For the estimation of SERT availability, the binding potential (BPND) was derived using the simplified reference tissue model (SRTM2). The Temperament and Character Inventory was used to measure self-transcendence. The analysis revealed that the self-transcendence total score had a significant negative correlation with the [(11)C]DASB BPND in the caudal raphe (R5). The subscale score for spiritual acceptance was significantly negatively correlated with the [(11)C]DASB BPND in the median raphe nucleus (R2). The results indicate that the self-transcendence trait is associated with SERT availability in specific raphe subnuclei, suggesting that the serotonin system may serve as an important biological basis for human self-transcendence. Based on the connections of these nuclei with cortico-limbic and visceral autonomic structures, the functional activity of these nuclei and their related neural circuitry may play a crucial role in the manifestation of self-transcendence. Copyright © 2015. Published by Elsevier B.V.

  16. Ocular and systemic pharmacokinetics of lidocaine hydrochloride ophthalmic gel in rabbits after topical ocular administration.

    Science.gov (United States)

    Liu, Bing; Ding, Li; Xu, Xiaowen; Lin, Hongda; Sun, Chenglong; You, Linjun

    2015-12-01

    Lidocaine hydrochloride ophthalmic gel is a novel ophthalmic preparation for topical ocular anesthesia. The study is aimed at evaluating the ocular and systemic pharmacokinetics of lidocaine hydrochloride 3.5 % ophthalmic gel in rabbits after ocular topical administration. Thirty-six rabbits were randomly placed in 12 groups (3 rabbits per group). The rabbits were quickly killed according to their groups at 0 (predose), 0.0833, 0.167, 0.333, 0.667, 1, 1.5, 2, 3, 4, 6, and 8 h postdose and then the ocular tissue and plasma samples were collected. All the samples were analyzed by a validated LC-MS/MS method. The test result showed that the maximum concentration (C max) of lidocaine in different ocular tissues and plasma were all achieved within 20 min after drug administration, and the data of C max were (2,987 ± 1814) μg/g, (44.67 ± 12.91) μg/g, (26.26 ± 7.19) μg/g, (11,046 ± 2,734) ng/mL, and (160.3 ± 61.0) ng/mL for tear fluid, cornea, conjunctiva, aqueous humor, and plasma, respectively. The data of the elimination half-life in these tissues were 1.5, 3.2, 3.5, 1.9, and 1.7 h for tear fluid, cornea, conjunctiva, aqueous humor, and plasma, respectively. The intraocular lidocaine levels were significantly higher than that in plasma, and the elimination half-life of lidocaine in cornea, conjunctiva, and aqueous humor was relatively longer than that in tear fluid and plasma. The high intraocular penetration, low systemic exposure, and long duration in the ocular tissues suggested lidocaine hydrochloride 3.5 % ophthalmic gel as an effective local anesthetic for ocular anesthesia during ophthalmic procedures.

  17. Experimental differentiation of intraocular masses using ultrahigh-field magnetic resonance imaging--a case series.

    Directory of Open Access Journals (Sweden)

    Karen Falke

    Full Text Available PURPOSE: The case reports presented here were compiled to demonstrate the potential for improved diagnosis and monitoring of disease progress of intraocular lesions using ultrahigh-field magnetic resonance microscopy (MRM at 7.1 Tesla. METHODS: High-resolution ex vivo ocular magnetic resonance (MR images were acquired on an ultrahigh-field MR system (7.1 Tesla, ClinScan, Bruker BioScan, Germany using a 2-channel coil with 4 coil elements and T2-weighted turbo spin echo (TSE sequences of human eyes enucleated because of different intraocular lesions. Imaging parameters were: 40×40 mm field of view, 512×512 matrix, and 700 µm slice thickness. The results were correlated with in vivo ultrasound and histology of the enucleated eyes. RESULTS: Imaging was performed in enucleated eyes with choroidal melanoma, malignant melanoma of iris and ciliary body with scleral perforation, ciliary body melanoma, intraocular metastasis of esophageal cancer, subretinal bleeding in the presence of perforated corneal ulcer, hemorrhagic choroidal detachment, and premature retinopathy with phthisis and ossification of bulbar structures. MR imaging allowed differentiation between solid and cystic tumor components. In case of hemorrhage, fluid-fluid levels were identified. Melanin and calcifications caused significant hypointensity. Microstructural features of eye lesions identified by MRM were confirmed by histology. CONCLUSION: This study demonstrates the potential of MRM for the visualization and differential diagnosis of intraocular lesions. At present, the narrow bore of the magnet still limits the use of this technology in humans in vivo. Further advances in ultrahigh-field MR imaging will permit visualization of tumor extent and evaluation of nonclassified intraocular structures in the near future.

  18. Paradigm Shifts in Ophthalmic Diagnostics.

    Science.gov (United States)

    Sebag, J; Sadun, Alfredo A; Pierce, Eric A

    2016-08-01

    Future advances in ophthalmology will see a paradigm shift in diagnostics from a focus on dysfunction and disease to better measures of psychophysical function and health. Practical methods to define genotypes will be increasingly important and non-invasive nanotechnologies are needed to detect molecular changes that predate histopathology. This is not a review nor meant to be comprehensive. Specific topics have been selected to illustrate the principles of important paradigm shifts that will influence the future of ophthalmic diagnostics. It is our impression that future evaluation of vision will go beyond visual acuity to assess ocular health in terms of psychophysical function. The definition of disease will incorporate genotype into what has historically been a phenotype-centric discipline. Non-invasive nanotechnologies will enable a paradigm shift from disease detection on a cellular level to a sub-cellular molecular level. Vision can be evaluated beyond visual acuity by measuring contrast sensitivity, color vision, and macular function, as these provide better insights into the impact of aging and disease. Distortions can be quantified and the psychophysical basis of vision can be better evaluated than in the past by designing tests that assess particular macular cell function(s). Advances in our understanding of the genetic basis of eye diseases will enable better characterization of ocular health and disease. Non-invasive nanotechnologies can assess molecular changes in the lens, vitreous, and macula that predate visible pathology. Oxygen metabolism and circulatory physiology are measurable indices of ocular health that can detect variations of physiology and early disease. This overview of paradigm shifts in ophthalmology suggests that the future will see significant improvements in ophthalmic diagnostics. The selected topics illustrate the principles of these paradigm shifts and should serve as a guide to further research and development. Indeed

  19. Sea Level History in 3D: Early results of an ultra-high resolution MCS survey across IODP Expedition 313 drillsites

    Science.gov (United States)

    Mountain, G. S.; Kucuk, H. M.; Nedimovic, M. R.; Austin, J. A., Jr.; Fulthorpe, C.; Newton, A.; Baldwin, K.; Johnson, C.; Stanley, J. N.; Bhatnagar, T.

    2015-12-01

    Although globally averaged sea level is rising at roughly 3 mm/yr (and is accelerating), rates of local sea-level change measured at coastlines may differ from this number by a factor of two or more; at some locations, sea level may even be falling. This is due to local processes that can match or even reverse the global trend, making it clear that reliable predictions of future impacts of sea-level rise require a firm understanding of processes at the local level. The history of local sea-level change and shoreline response is contained in the geologic record of shallow-water sediments. We report on a continuing study of sea-level history in sediments at the New Jersey continental margin, where compaction and glacial isostatic adjustment are currently adding 2 mm/yr to the globally averaged rise. We collected 570 sq km of ultra-high resolution 3D MCS data aboard the R/V Langseth in June-July 2015; innovative recording and preliminary results are described by Nedimovic et al. in this same session. The goal was to provide regional context to coring and logging at IODP Exp 313 sites 27-29 that were drilled 750 m into the New Jersey shelf in 2009. These sites recovered a nearly continuous record of post-Eocene sediments from non-marine soils, estuaries, shoreface, delta front, pro-delta and open marine settings. Existing seismic data are good but are 2D high-resolution profiles at line spacings too wide to enable mapping of key nearshore features. The Langseth 3D survey used shallow towing of a tuned air gun array to preserve high frequencies, and twenty-four 50-m PCables each 12.5 apart provided 6.25 x 3.125 m common-midpoint bins along seventy-seven 50-km sail lines. With this especially dense spatial resolution of a pre-stack time migrated volume we expect to map rivers, incised valleys, barrier islands, inlets and bays, pro-delta clinoforms, tidal deltas, sequence boundaries, debris flow aprons, and more. Seismic attributes linked to sedimentary facies and

  20. New Visualization Techniques to Analyze Ultra-High Resolution Four-dimensional Surface Deformation Imagery Collected With Ground-based Tripod LiDAR

    Science.gov (United States)

    Kreylos, O.; Bawden, G. W.; Kellogg, L. H.

    2005-12-01

    We are developing a visualization application to display and interact with very large (tens of millions of points) four-dimensional point position datasets in an immersive environment such that point groups from repeated Tripod LiDAR (Light Detection And Ranging) surveys can be selected, measured, and analyzed for land surface change using 3D~interactions. Ground-based tripod or terrestrial LiDAR (T-LiDAR) can remotely collect ultra-high resolution (centimeter to subcentimeter) and accurate (± 4 mm) digital imagery of the scanned target, and at scanning rates of 2,000 (x, y, z, i) (3D~position~+ intensity) points per second over 7~million points can be collected for a given target in an hour. We developed a multiresolution point set data representation based on octrees to display large T-LiDAR point cloud datasets at the frame rates required for immersive display (between 60 Hz and 120 Hz). Data inside an observer's region of interest is shown in full detail, whereas data outside the field of view or far away from the observer is shown at reduced resolution to provide context. Using 3D input devices at the University of California Davis KeckCAVES, users can navigate large point sets, accurately select related point groups in two or more point sets by sweeping regions of space, and guide the software in deriving positional information from point groups to compute their displacements between surveys. We used this new software application in the KeckCAVES to analyze 4D T-LiDAR imagery from the June~1, 2005 Blue Bird Canyon landslide in Laguna Beach, southern California. Over 50~million (x, y, z, i) data points were collected between 10 and 21~days after the landslide to evaluate T-LiDAR as a natural hazards response tool. The visualization of the T-LiDAR scans within the immediate landslide showed minor readjustments in the weeks following the primarily landslide with no observable continued motion on the primary landslide. Recovery and demolition efforts across the

  1. Application and study of conjunctival sac disinfectants in ophthalmic surgeries

    Directory of Open Access Journals (Sweden)

    Yan-Fei Luo

    2016-01-01

    Full Text Available Postoperative endophthalmitis is the most serious complications of ophthalmic surgeries. Conjunctival sac disinfection is currently recognized as an effectively important way to reduce the risk of endophthalmitis. At present, there are some disinfectants has been used in clinic or in the researches:mercury agent, gentamicin, povidone iodine and acid electrolytic water. All kinds of disinfectants play the role of disinfection by different ways. Povidone iodine is the most widely used conjunctival sac disinfectant. Mercurial and gentamicin have been rarely used because they pollute the environment, are easy to cause drug resistant bacteria, localized side reactions and so on. The acid electrolyte water is not used in clinic at present. With the popularization and development of the ophthalmic surgeries, the ophthalmologists have become more and more concerned about the postoperative eye comfort, the research and application of conjunctival sac disinfectant in the future will continue to be updated and developed.

  2. Clinical use of gatifloxacin ophthalmic solution for treatment of bacterial conjunctivitis

    Directory of Open Access Journals (Sweden)

    Cervantes LJ

    2011-04-01

    Full Text Available Lorenzo J Cervantes, Francis S MahDepartment of Ophthalmology, Cornea and External Disease, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USAAbstract: Bacterial conjunctivitis is a common infectious disease of the eye, characterized by conjunctival hyperemia, eyelid edema, and purulent discharge. Although the prevalence and incidence are not well reported, bacterial conjunctivitis represents one of the most frequent causes of patient visits to both primary care physicians and ophthalmologists. Most cases of nongonococcal and nonchlamydial bacterial conjunctivitis are self-limiting and may resolve without intervention. There is a place for treatment, however, which allows for a shorter time to clinical and microbiological resolution which may decrease the mild morbidity, decrease health care costs of visits and potential complications, return patients back to school or the work force, and limit the potential spread of this communicable infection. Gatifloxacin ophthalmic solution is a broad spectrum 8-methoxyfluroroquinolone bactericidal antibiotic, with good activity against Staphylococcus aureus, Streptococcus species, and Gram-negative pathogens. It also has a relatively good resistance profile, making it a more than adequate choice in the treatment of bacterial conjunctivitis when therapy is warranted.Keywords: gatifloxacin, Zymar®, Zymaxid®, bacterial conjunctivitis

  3. Optimization and evaluation of thermoresponsive diclofenac sodium ophthalmic in situ gels.

    Science.gov (United States)

    Asasutjarit, Rathapon; Thanasanchokpibull, Suthira; Fuongfuchat, Asira; Veeranondha, Sukitaya

    2011-06-15

    This work was conducted to optimize and evaluate Pluronic F127-based thermoresponsive diclofenac sodium ophthalmic in situ gels (DS in situ gel). They were prepared by cold method and investigated their physicochemical properties i.e., pH, flow ability, sol-gel transition temperature, gelling capacity and rheological properties. An optimized formulation was selected and investigated its physicochemical properties before and after autoclaving, eye irritation potency in SIRC cells and rabbits. In vivo ophthalmic absorption was performed in rabbits. It was found that physicochemical properties of DS in situ gels were affected by formulation compositions. Increment of Pluronic F127 content decreased sol-gel transition temperature of the products while increase in Pluronic F68 concentration tended to increase sol-gel transition temperature. In this study, Carbopol 940 did not affect sol-gel transition temperature but it affected transparency, pH, and gelling capacity of the products. The optimized formulation exhibited sol-gel transition at 32.6 ± 1.1 °C with pseudoplastic flow behavior. It was lost diclofenac sodium content during autoclaving. However, it was accepted as safe for ophthalmic use and could increase diclofenac sodium bioavailability in aqueous humor significantly. In conclusion, the optimized DS in situ gel had potential for using as an alternative to the conventional diclofenac sodium eye drop. However, autoclaving was not a suitable sterilization method for this product. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Local toxicity of benzalkonium chloride in ophthalmic solutions following repeated applications.

    Science.gov (United States)

    Okahara, Akihiko; Kawazu, Kouichi

    2013-01-01

    We performed repeated toxicity studies of benzalkonium chloride (BAK)-containing vehicles of ophthalmic solutions in monkeys and rabbits to assess the local toxicity of BAK after repeated applications on the ocular surface. Local toxicity of BAK was evaluated by toxicity studies in which a 0.01% BAK-containing vehicle was applied twice/day for 52 weeks, 4 times/day for 39 weeks, or 6 times/day for 13 weeks, or in which a 0.005% BAK-containing vehicle was applied 6 times/day for 52 weeks or twice/day for 4 weeks in monkeys. Local toxicity of BAK was also evaluated where a 0.01% BAK-containing vehicle was applied 6 times/day for 6 weeks, or a 0.005% BAK-containing vehicle was applied twice/day for 39 weeks or 8 times/day for 4 weeks in rabbits. These doses were chosen because BAK is generally used at concentrations up to 0.01% in ophthalmic solutions. The BAK-containing vehicle did not cause ophthalmological changes suggestive of irritation, allergy, or corneal damage. We also did not observe any histopathological changes in the eyeball, eyelid, lacrimal gland, and nasal cavity, with repeated applications of BAK for up to 52 weeks, up to 8 times/day, or at concentrations up to 0.01%, in monkeys and rabbits. Our results suggest that BAK in concentrations up to 0.01% in ophthalmic solution is non-toxic to the eyeball, its accessory organs, and the nasal cavity after long repeated applications.

  5. [Sinus pericranii associated to spontaneous thrombosis of the ophthalmic vein: neuroimaging studies].

    Science.gov (United States)

    Murias, E; Villota, E; Saiz, A; Gil, A; Calleja, S

    2009-01-01

    Sinus pericranii is an abnormal venous communication between the intracranial dural sinuses and epicranial venous dilatations. The periorbital location is uncommon; spontaneous partial thromboses of the subcutaneous varices have been reported in association with local signs and symptoms; however, to our knowledge there are no reports of sinus pericranii associated to thrombosis in the ophthalmic vein. Sinus pericranii is related to arteriovenous and lymphatic-venous malformations. We present the case of a patient with a generalized and diffuse disorder of venous drainage that affected the right cerebral hemisphere who presented at the emergency department with ophthalmologic signs and symptoms after thrombosis of the superior ophthalmic vein and who had three sinus pericranii located in the frontal, parietal, and occipital areas.

  6. Antimicrobial activity of a new preservative for multiuse ophthalmic solutions.

    Science.gov (United States)

    Ghelardi, Emilia; Celandroni, Francesco; Gueye, Sokhna A; Salvetti, Sara; Campa, Mario; Senesi, Sonia

    2013-01-01

    The aim of this study was to examine the antimicrobial activity and the preservative efficacy of a novel preservative solution containing sodium hydroxymethyl glycinate (SHMG) and edetate disodium (EDTA), which is used for preservation of some commercial ophthalmic formulations. In vitro susceptibility assays were performed against several gram-positive (Staphylococcus aureus, Staphylococcus epidermidis, and Bacillus cereus) and gram-negative (Escherichia coli and Pseudomonas aeruginosa) bacteria representative of the microbial flora of epithelial surfaces or colonizing the conjunctiva, as well as against Candida albicans and Aspergillus niger. Using different concentrations of SHMG alone or in combination with EDTA, the minimal inhibitory and microbicidal concentrations against these organisms were assessed. In addition, 8 brands of multidose eye drops containing 0.002% SHMG and 0.1% EDTA as preservative were tested for antimicrobial activity using the antimicrobial effectiveness test recommended by the international pharmacopoeias. The minimal inhibitory and bactericidal/fungicidal concentration values of SHMG ranged from 0.0025% to 0.0125% for bacteria and from 0.125% to 0.50% for mold and yeast. Susceptibility testing demonstrated that the addition of EDTA substantially increased the SHMG activity against all bacterial and fungal strains. The preservative effectiveness test was applied to commercial eye drops. All the drop solutions met the criteria reported by the U.S. Pharmacopeia for parenteral and ophthalmic preparations. All products also satisfied the major acceptance criteria of the European Pharmacopeia with respect to the antifungal activity. With regard to the antibacterial activity, the less-stringent criteria of the European Pharmacopeia were fulfilled. The present study demonstrates the efficacy of a novel preservative for ophthalmic solutions (SHMG/EDTA) and its activity in protecting selected commercial artificial tears against microbial

  7. Ophthalmic manifestations of methylmalonic aciduria accompanied with homocystinuria

    Directory of Open Access Journals (Sweden)

    Qiu-Jing Huang

    2015-12-01

    Full Text Available Methylmalonicaciduia(MMAaccompanied with homocystinuria is a rare autosomal-recessive with congenital metabolic disorder of Vitamin B12. There are three subtypes, cblC, cblD, cblF, in which cblC is the most common one. The diagnostic tests are tandem mass spectrometry and gas chromatography-mass spectrometry. Tests for activity of enzyme in fibroblasts from skin, complementary assay and genetic analysis can be used to make the subtype clear. Early-onset patients, defined by onset of symptoms before the age of 1 year, may have severe ocular involvement, including visual loss, nystagmus, strabismus, retinopathy, maculopathy, optic atrophy, abnormal electroretinography. Late-onset patients, defined by onset of symptoms after the age of 4 year, rarely have ocular manifestations. The pathogenesis of the ophthalmic symptoms may be related to the high level of homocystine, oxidative stress and the abnormal development of nervous systems. The treatment for MMA accompanied with homocystinuria is mostly symptomatic based. Ophthalmic treatment is limited. Early supplement of methionine,GSH or other antioxidants may be helpful for retinopathy. There is no standard ophthalmological examination for those patients in China. It is critical to set up inter-departmental cooperation and early stage examination for the treatments and outcomes of the patients.

  8. Ophthalmic Skills Assessment of Primary Health Care Workers at ...

    African Journals Online (AJOL)

    Proficiency in the basic ophthalmic skills is a cri cal factor in the effec ve delivery of eye care services at the primary level of care. The aim of the study was to assess the ability of ... out visual acuity test and correctly iden fy cataract and conjunc vi s using pictures of eye condi ons and ..... Medical Laboratory Technician.

  9. Does Uniformity of Topical Corticosteroid Ophthalmic Medications: Flourometholone Acetate 0.1 Suspension and Loteprednol Etabonate 0.5 gel

    Science.gov (United States)

    2017-01-03

    following ocular surgery.1 They are available in different forms including emulsions , ointments, solutions, gels, and suspensions. The choice of...study done by Stringer and Bryant compared dose uniformity of difluprednate ophthalmic emulsion (Durezol®) with prednisolone acetate (brand name...topical ophthalmic corticosteroid suspensions. Am J Ophthalmol. 1979;87(2): 210- 214. 5 Flarex® [ package insert]. Fort Worth, TX: Alcon Laboratories Inc

  10. Electrospray deposition of fullerenes in ultra-high vacuum: in situ scanning tunneling microscopy and photoemission spectroscopy

    International Nuclear Information System (INIS)

    Satterley, Christopher J; Perdigao, LuIs M A; Saywell, Alex; Magnano, Graziano; Rienzo, Anna; Mayor, Louise C; Dhanak, Vinod R; Beton, Peter H; O'Shea, James N

    2007-01-01

    Electrospray deposition of fullerenes on gold has been successfully observed by in situ room temperature scanning tunneling microscopy and photoemission spectroscopy. Step-edge decoration and hexagonal close-packed islands with a periodicity of 1 nm are observed at low and multilayer coverages respectively, in agreement with thermal evaporation studies. Photoemission spectroscopy shows that fullerenes are being deposited in high purity and are coupling to the gold surface as for thermal evaporation. These results open a new route for the deposition of thermally labile molecules under ultra-high vacuum conditions for a range of high resolution surface science techniques

  11. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes

    Science.gov (United States)

    Koh, Shizuka

    2015-01-01

    Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of “Tear Film Oriented Therapy (TFOT)”, an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described. PMID:26028958

  12. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes.

    Science.gov (United States)

    Koh, Shizuka

    2015-01-01

    Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of "Tear Film Oriented Therapy (TFOT)", an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described.

  13. Imaging at ultrahigh magnetic fields: History, challenges, and solutions.

    Science.gov (United States)

    Uğurbil, Kamil

    2018-03-01

    Following early efforts in applying nuclear magnetic resonance (NMR) spectroscopy to study biological processes in intact systems, and particularly since the introduction of 4 T human scanners circa 1990, rapid progress was made in imaging and spectroscopy studies of humans at 4 T and animal models at 9.4 T, leading to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has provided numerous technological solutions to challenges posed at these ultrahigh fields, and demonstrated the existence of significant advantages in signal-to-noise ratio and biological information content. Primary difference from lower fields is the deviation from the near field regime at the radiofrequencies (RF) corresponding to hydrogen resonance conditions. At such ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image non-uniformities for a given sample-coil configuration because of destructive and constructive interferences. These non-uniformities were initially considered detrimental to progress of imaging at high field strengths. However, they are advantageous for parallel imaging in signal reception and transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies and improvements in instrumentation and imaging methods, today ultrahigh fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Ultra-high energy cosmic rays and prompt TeV gamma rays from ...

    Indian Academy of Sciences (India)

    physics pp. 789-792. Ultra-high energy cosmic rays and prompt. TeV gamma rays from gamma ray bursts ... The origin of the observed ultra-high energy cosmic ray (UHECR) events with ... are proton and electron rest mass, respectively.

  15. Refinement procedure for the image alignment in high-resolution electron tomography.

    Science.gov (United States)

    Houben, L; Bar Sadan, M

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Common causes of red eye presenting at an ophthalmic clinic ...

    African Journals Online (AJOL)

    Background: Redness of the eye is a common ophthalmic symptom. The problem causing redness could arise from within or outside the globe. These range from cases of simple inflammation following itching and minor trauma for example, to severe cases like orbital cellulitis and tumours. Patients may not even be aware of ...

  17. Efficacy of detergent and water versus bleach for disinfection of direct contact ophthalmic lenses.

    Science.gov (United States)

    Abbey, Ashkan M; Gregori, Ninel Z; Surapaneni, Krishna; Miller, Darlene

    2014-06-01

    Although manufacturers recommend cleaning ophthalmic lenses with detergent and water and then with a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus that of bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus and 2 viral strains (adenovirus and herpes simplex virus [HSV] type-1) were individually inoculated onto 20 gonioscopy and laser lenses. The lenses were washed with detergent and water and then disinfected with 10% bleach. All the lenses were cultured after inoculation, after washing with detergent and water, and after disinfecting with the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks, and viral cultures were observed for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). All 20 lenses inoculated with S. epidermidis, C. straitum, adenovirus, and HSV-1 showed growth after inoculation but no growth after washing with detergent/water and after disinfecting with the bleach. All lenses showed positive HSV and adenovirus PCR results after inoculation and negative PCR results after washing with detergent/water and after disinfecting with bleach. All methicillin-resistant S. aureus-contaminated lenses showed growth after inoculation and no growth after washing with detergent and water. However, 1 lens showed positive growth after disinfecting with bleach. Cleaning with detergent and water seemed to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage.

  18. Facilitation of tear fluid secretion by 3% diquafosol ophthalmic solution in normal human eyes.

    Science.gov (United States)

    Yokoi, Norihiko; Kato, Hiroaki; Kinoshita, Shigeru

    2014-01-01

    To evaluate the increase in tear fluid volume induced by 3% diquafosol ophthalmic solution in normal human eyes. Prospective, randomized, double-masked, comparative study. Twenty healthy adults (17 males and 3 females; mean age, 38.8 years) underwent topical instillation of 2 ophthalmic solutions, artificial tears in 1 eye and 3% diquafosol ophthalmic solution in the fellow eye, in a masked manner. The radius of curvature of the central lower tear meniscus was measured at 5, 10, 15, 30, and 60 minutes after instillation by use of reflective meniscometry, and subjects' self-evaluated symptoms of wetness and stinging using a visual analog scale. Changes after instillation in the radius of curvature from baseline (artificial tear group vs diquafosol group; mean ± standard error of the mean) were as follows: at 5 minutes, -0.008 ± 0.012 vs 0.045 ± 0.013; at 10 minutes, 0.001 ± 0.014 vs 0.057 ± 0.016; at 15 minutes, -0.012 ± 0.014 vs 0.037 ± 0.019; at 30 minutes, -0.010 ± 0.016 vs 0.030 ± 0.025; and at 60 minutes, -0.029 ± 0.012 vs -0.020 ± 0.012. The diquafosol group showed significantly greater values from 5 to 30 minutes after instillation. Of the 40 eyes, 13 showed abnormal tear film breakup time (≤5 seconds). The diquafosol group had significantly more wetness at 15 minutes after instillation than did the artificial tear group. Topical instillation of 3% diquafosol ophthalmic solution increases tear fluid on the ocular surface for up to 30 minutes in normal human eyes. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  20. The impact of the European Working Time Regulations on Ophthalmic Specialist Training--a national trainee survey.

    Science.gov (United States)

    O'Gallagher, M K; Lewis, G; Mercieca, K; Moutray, T

    2013-01-01

    To assess ophthalmic trainees' perspective of the impact of the European Working Time Regulations (EWTR) on their training. All trainees in ophthalmology in the UK were emailed a link to an electronic survey asking about their experiences of the EWTR. 324 trainees (46% of those invited) responded to the survey. 44.4% of trainees reported that their posts were compliant with the EWTR. 40.7% felt that training had been adversely affected. 49.1% thought that ophthalmic trainees should opt out of the EWTR to work more than 48 h per week, with 57 the mean number of hours suggested appropriate. Many ophthalmic trainees in the United Kingdom are working in rotas which are not compliant with the European Working Time Directive. Many trainees feel that implementation of the EWTD has had a negative effect on training and feel it would be acceptable to work a higher number of hours per week. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  1. Bromfenac ophthalmic solution for the treatment of postoperative ocular pain and inflammation: safety, efficacy, and patient adherence

    OpenAIRE

    Rajpal, Rajesh K; Ross, Bryan; Rajpal, Sachin D; Hoang, Khoa

    2014-01-01

    Rajesh K Rajpal, Bryan Ross, Sachin D Rajpal, Khoa HoangSee Clearly Vision Group, McLean, VA, USAAbstract: Ophthalmic nonsteroidal anti-inflammatory drugs (NSAIDs) are commonly used by clinicians to manage ocular inflammation and pain following cataract surgery. Over the past decade, the US Food and Drug Administration has approved multiple topical NSAIDs for these purposes, including several reformulated products. One of these medications, bromfenac ophthalmic solution, has a long and extens...

  2. Production of ultrahigh magnetic fields. Technical progress report

    International Nuclear Information System (INIS)

    1985-01-01

    The objective was to produce and measure controlled ultrahigh magnetic fields by imploding a plasma in which a magnetic field has been entrained. The novel method for producing the ultrahigh fields using a gas-puff Z pinch was tested successfully and found to work as well as predicted in some respects and better in others, such as field amplification. Moreover, in testing this concept, we may have created the only megagauss facility in the world with a 3-minute repetition rate and long lifetime. Most megagauss facilities are single-shot, owing to material deformations or the use of explosives

  3. Shock characterization of an ultra-high strength concrete

    International Nuclear Information System (INIS)

    Erzar, B.; Pontiroli, C.; Buzaud, E.

    2016-01-01

    Nowadays, the design of protective structures may imply ultra-high performance concretes. These materials present a compressive strength 5 times higher than standard concretes. However, few reliable data on the shock response of such materials are available in the literature. Thus, a characterization of an ultra-high strength concrete has been conducted by means of hydrostatic and triaxial tests in the quasi-static regime, and plate impact experiments for shock response. Data have been gathered up to 6 GPa and a simple modelling approach has been applied to get a reliable representation of the shock compression of this concrete. (authors)

  4. OPHTHALMIC FINDINGS IN LATE STAGE SJOGREN-LARSSON SYNDROME.

    Science.gov (United States)

    Nanda, Tavish; Kovach, Jaclyn L

    2017-03-15

    To report spectral domain optical coherence tomography and fundus autofluorescence documentation of late stage macular findings associated with Sjogren-Larsson Syndrome in three adult siblings. Three adult siblings with Sjogren-Larsson Syndrome underwent ophthalmic examination and imaging. Crystalline maculopathy and subretinal deposits, presumably lipofuscin accumulation, with macular atrophy were present in varying degrees in all three adult siblings. In adults with Sjogren-Larsson Syndrome, crystalline retinopathy can progress to macular atrophy and the appearance of lipofuscin accumulation.

  5. Ultrahigh vacuum STM/STS studies of the Bi-O surface in Bi2Sr2CuOy single crystals

    International Nuclear Information System (INIS)

    Ikeda, Kazuto; Tomeno, Izumi; Takamuku, Kenshi; Yamaguchi, Koji; Itti, Rittaporn; Koshizuka, Naoki

    1992-01-01

    Scanning tunneling microscopic and spectroscopic studies were made on cleaved surfaces of Bi 2 Sr 2 CuO y single crystals using an ultrahigh-vacuum scanning tunneling microscope (UHV-STM). The modulation structures of the Bi-O surface were observed at room temperature with atomic resolution. The tunneling spectra showed electronic gap structures similar to those observed for the Bi-O surface of superconducting Bi-2212 single crystals. This suggests that superconductivity is not directly related to the electronic structure observed in the Bi-O plane. (orig.)

  6. Efficacy of Detergent and Water Versus Bleach for the Disinfection of Direct Contact Ophthalmic Lenses

    Science.gov (United States)

    Abbey, Ashkan M.; Gregori, Ninel Z.; Surapaneni, Krishna; Miller, Darlene

    2014-01-01

    Purpose While manufacturers recommend cleaning ophthalmic lenses with detergent and water and then a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Methods Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus (MRSA) and two viral strains (adenovirus and herpes simplex virus (HSV) type-1) were individually inoculated to 20 gonioscopy and laser lenses. Lenses were washed with detergent and water and then disinfected with 10% bleach. All lenses were cultured after inoculation, after detergent and water, and after the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks and viral cultures for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). Results All 20 lenses inoculated with Staphylococcus epidermidis, Corynebacterium straitum, adenovirus, and HSV-1 showed growth after inoculation, but no growth after detergent/water and after the bleach. All lenses showed positive HSV and adenovirus PCR after inoculation and negative PCR after detergent/water and after bleach. All MRSA contaminated lenses showed growth after inoculation and no growth after detergent and water. However, one lens showed positive growth after bleach. Conclusions Cleaning with detergent and water appeared to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage. PMID:24747806

  7. Design of Novel Ophthalmic Formulation Containing Drug Nanoparticles and Its Usefulness as Anti-glaucoma Drugs.

    Science.gov (United States)

    Nagai, Noriaki

    2016-01-01

    The ophthalmic application of drugs is the primary route of administration for the therapy of glaucoma; however, in traditional formulations, only small amounts of the administered drug penetrate the cornea to reach the desired intraocular tissue due to corneal barriers. Recently, nanoparticulate drug delivery is expected as a technology to overcome the difficulties in delivering drugs across biological barriers (improvement of bioavailability). In this study, we attempted to establish a new method for preparing solid drug nanoparticles by using a bead mill and various additives, and succeeded in preparing a high quality dispersion containing drug nanoparticles. For a more concrete example, a mean particle size of disulfiram (DSF) treated with bead mill is 183 nm. The corneal penetration and corneal residence time of DSF from the ophthalmic dispersion containing DSF nanoparticles were significantly higher than those from a 2-hydroxypropyl-β-cyclodextrin solution containing DSF (DSF solution). It is known that the administration of DSF has intraocular pressure (IOP)-reducing effects. The IOP-reducing effects of the ophthalmic dispersion containing DSF nanoparticles were significantly greater than those of the DSF solution in rabbits (the IOP was enhanced by placing the rabbits in a dark room for 5 h). In addition, the ophthalmic dispersion containing DSF nanoparticles is better tolerated by corneal epithelial cells than DSF solution. It is possible that dispersions containing DSF nanoparticles provide new possibilities for effectively treating glaucoma, and that ocular drug delivery systems using drug nanoparticles may expand their usage for therapy in the ophthalmologic field.

  8. [Application study of qualitatively diagnosing prostate cancer using ultrahigh b-value DWI].

    Science.gov (United States)

    Ji, L B; Lu, Z H; Yao, H H; Cao, Y; Lu, W W; Qian, W X; Wang, X M; Hu, C H

    2017-07-18

    Objective: To explore the value of ultrahigh b-value DWI in diagnosis of prostate cancer. Methods: From October 2015 to October 2016, a total of 84 cases from Affiliated Changshu Hospital of Soochow University(39 cases of prostate cancer with a total of 57 lesions, 45 cases of benign prostate hyperplasia) were examined with T(2)WI, high b-value DWI (b=1 000 s/mm(2)) and ultrahigh b-value DWI (b=2 000 s/mm(2)) .Three image sets were rated respectively based on PI-RADS V2 by two radiologists and the scores were compared with biopsy results.The differences of the area under the ROC curve (AUC) among the three groups of each observer were compared by Z test. Results: The difference of AUC between ultrahigh b-value DWI and T(2)WI in the diagnosis of peripheral and transitional zone cancer was statistically significant between the two observers ( P =0.009 9, 0.008 2, 0.010 8 and 0.004 5 respectively), and there was no significant difference of AUC between ultrahigh b-value DWI and high b-value DWI in the diagnosis of peripheral and transitional zone cancer.The inter-reader agreement was found to be perfect for all lesions, peripheral zone lesions and transition zone lesions at ultrahigh b-value DWI ( kappa values were 0.738, 0.709 and 0.768 respectively). Conclusion: The diagnostic performance of ultrahigh b-value DWI is superior to high b-value DWI and T(2)WI in both peripheral zone and transition zone cancers.

  9. Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

    Science.gov (United States)

    Tsai, Tsung-Han; Potsaid, Benjamin; Tao, Yuankai K; Jayaraman, Vijaysekhar; Jiang, James; Heim, Peter J S; Kraus, Martin F; Zhou, Chao; Hornegger, Joachim; Mashimo, Hiroshi; Cable, Alex E; Fujimoto, James G

    2013-07-01

    We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 μm axial resolution, 8 μm lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated.

  10. Diffuse axonal injury at ultra-high field MRI.

    Directory of Open Access Journals (Sweden)

    Christoph Moenninghoff

    Full Text Available Diffuse axonal injury (DAI is a specific type of traumatic brain injury caused by shearing forces leading to widespread tearing of axons and small vessels. Traumatic microbleeds (TMBs are regarded as a radiological marker for DAI. This study aims to compare DAI-associated TMBs at 3 Tesla (T and 7 T susceptibility weighted imaging (SWI to evaluate possible diagnostic benefits of ultra-high field (UHF MRI.10 study participants (4 male, 6 female, age range 20-74 years with known DAI were included. All MR exams were performed with a 3 T MR system (Magnetom Skyra and a 7 T MR research system (Magnetom 7 T, Siemens AG, Healthcare Sector, Erlangen, Germany each in combination with a 32-channel-receive coil. The average time interval between trauma and imaging was 22 months. Location and count of TMBs were independently evaluated by two neuroradiologists on 3 T and 7 T SWI images with similar and additionally increased spatial resolution at 7 T. Inter- and intraobserver reliability was assessed using the interclass correlation coefficient (ICC. Count and diameter of TMB were evaluated with Wilcoxon signed rank test.Susceptibility weighted imaging revealed a total of 485 TMBs (range 1-190, median 25 at 3 T, 584 TMBs (plus 20%, range 1-262, median 30.5 at 7 T with similar spatial resolution, and 684 TMBs (plus 41%, range 1-288, median 39.5 at 7 T with 10-times higher spatial resolution. Hemorrhagic DAI appeared significantly larger at 7 T compared to 3 T (p = 0.005. Inter- and intraobserver correlation regarding the counted TMB was high and almost equal 3 T and 7 T.7 T SWI improves the depiction of small hemorrhagic DAI compared to 3 T and may be supplementary to lower field strengths for diagnostic in inconclusive or medicolegal cases.

  11. The intergalactic propagation of ultrahigh energy cosmic ray nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Hooper, Dan; /Fermilab; Sarkar, Subir; /Oxford U., Theor. Phys.; Taylor, Andrew M.; /Oxford U.

    2006-08-01

    We investigate the propagation of ultra-high energy cosmic ray nuclei (A = 1-56) from cosmologically distant sources through the cosmic radiation backgrounds. Various models for the injected composition and spectrum and of the cosmic infrared background are studied using updated photodisintegration cross-sections. The observational data on the spectrum and the composition of ultra-high energy cosmic rays are jointly consistent with a model where all of the injected primary cosmic rays are iron nuclei (or a mixture of heavy and light nuclei).

  12. Deep lateral wall orbital decompression following strabismus surgery in patients with Type II ophthalmic Graves' disease.

    Science.gov (United States)

    Ellis, Michael P; Broxterman, Emily C; Hromas, Alan R; Whittaker, Thomas J; Sokol, Jason A

    2018-01-10

    Surgical management of ophthalmic Graves' disease traditionally involves, in order, orbital decompression, followed by strabismus surgery and eyelid surgery. Nunery et al. previously described two distinct sub-types of patients with ophthalmic Graves' disease; Type I patients exhibit no restrictive myopathy (no diplopia) as opposed to Type II patients who do exhibit restrictive myopathy (diplopia) and are far more likely to develop new-onset worsening diplopia following medial wall and floor decompression. Strabismus surgery involving extra-ocular muscle recession has, in turn, been shown to potentially worsen proptosis. Our experience with Type II patients who have already undergone medial wall and floor decompression and strabismus surgery found, when additional decompression is necessary, deep lateral wall decompression (DLWD) appears to have a low rate of post-operative primary-gaze diplopia. A case series of four Type II ophthalmic Graves' disease patients, all of whom had already undergone decompression and strabismus surgery, and went on to develop worsening proptosis or optic nerve compression necessitating further decompression thereafter. In all cases, patients were treated with DLWD. Institutional Review Board approval was granted by the University of Kansas. None of the four patients treated with this approach developed recurrent primary-gaze diplopia or required strabismus surgery following DLWD. While we still prefer to perform medial wall and floor decompression as the initial treatment for ophthalmic Graves' disease, for proptosis following consecutive strabismus surgery, DLWD appears to be effective with a low rate of recurrent primary-gaze diplopia.

  13. 1300 nm and 890 nm OCT images of oral cancer tissue engineered models and biopsy samples offer complimentary performance (Conference Presentation)

    Science.gov (United States)

    Boadi, Joseph; Byers, Robert A.; Fernandes, Jon; Mittar, Shweta; Hearnden, Vanessa; Lu, Zenghai; MacNeil, Sheila; Thornhill, Martin; Murdoch, Craig; Hunter, Keith D.; McKechnie, Alasdair; Matcher, Stephen J.

    2016-02-01

    OCT has demonstrated great potential to non-invasively detect oral epithelial cancers, potentially guiding biopsy and surgical resection. On non-ophthalmic tissues the preferred illumination wavelength is 1300 nm. Previous studies on skin have shown that useful image data can also be obtained at shorter wavelengths, with systems at 1060 nm and 820 nm offering reduced depth penetration but higher contrast. Here we apply a similar comparison to tissue engineered models of oral cancer and also to human biopsy samples, generally finding a similar trend. 1300 nm multi-beam OCT (Michelson Diagnostics EX1301) visualises stromal structures and surface keratin more clearly, providing useful image contrast down to around 1 mm. This system was compared with an ultra-high resolution home-built system operating at 890 nm (2.5 micron resolution vs 7.5 micron axial resolution for the EX1301). The UHR system reveals epithelial features more clearly, especially in the DOK pre-invasive cell line model and the biopsy samples. The relative effects of center wavelength vs axial resolution in generating the differential, wavelength-dependent contrast are assessed and the OCT biopsy images are compared with contemporary histology.

  14. Digital video recording and archiving in ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Raju Biju

    2006-01-01

    Full Text Available Currently most ophthalmic operating rooms are equipped with an analog video recording system [analog Charge Couple Device camera for video grabbing and a Video Cassette Recorder for recording]. We discuss the various advantages of a digital video capture device, its archiving capabilities and our experience during the transition from analog to digital video recording and archiving. The basic terminology and concepts related to analog and digital video, along with the choice of hardware, software and formats for archiving are discussed.

  15. 10 CFR 35.491 - Training for ophthalmic use of strontium-90.

    Science.gov (United States)

    2010-01-01

    ... the requirements in paragraph (b) of this section and has achieved a level of competency sufficient to... require the authorized user of strontium-90 for ophthalmic radiotherapy to be a physician who— (a) Is an...; (iii) Mathematics pertaining to the use and measurement of radioactivity; and (iv) Radiation biology...

  16. Influence of Ophthalmic Solutions on Tear Components.

    Science.gov (United States)

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko

    2016-11-01

    Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.

  17. Ophthalmic Artery Embolization as Pretreatment of Orbital Exenteration for Conjunctival Squamous Cell Carcinoma

    International Nuclear Information System (INIS)

    Matsuo, Toshihiko; Ohara, Nobuya; Namba, Yuzaburo; Koshima, Isao; Ida, Kentaro; Kanazawa, Susumu

    2009-01-01

    The aim of this study is to describe the effect of transarterial embolization from the ophthalmic artery as a pretreatment for orbital exenteration. A 75-year-old Chinese man with a 7-year history of gradual increase of the left eye swelling showed a massive conjunctival tumor growing outwardly from the interpalpebral fissure and had no light perception in the left eye. Magnetic resonance imaging showed orbital invasion of the tumor around the left eyeglobe. The initial surgery for the planned orbital exenteration was discontinued after skin incision around the orbital margin due to massive hemorrhage. The patient underwent transarterial embolization with gelatin sponge (Spongel) of the feeding arteries from the left ophthalmic artery and, the next day, had orbital exenteration with well-controllable bleeding and reconstruction with free vascularized anterolateral thigh cutaneous flap transfer. Pathologically, well-differentiated squamous cell carcinoma proliferated in exophytic, papillary, and nested fashions, arising from the bulbar conjunctiva. Tumor cells were also found in the conjunctival stroma around the vessels. The sclera at the equator had a perforated site with tumor cell invasion, but no intraocular invasion was found. Hematoxylin-positive gelatin sponges were found inside the orbital vessels and large choroidal vessels. In conclusion, transarterial embolization of feeding arteries arising from the ophthalmic artery is a useful pretreatment to control bleeding at orbital exenteration for malignancy.

  18. The variability of the isotopic signal during the last Glacial as seen from the ultra-high resolution NEEM and NorthGRIP ice cores.

    Science.gov (United States)

    Gkinis, Vasileios; Møllesøe Vinther, Bo; Terkelsen Holme, Christian; Capron, Emilie; Popp, Trevor James; Olander Rasmussen, Sune

    2017-04-01

    The continuity and high resolution available in polar ice core records constitutes them an excellent tool for the study of the stadial-interstadial transitions, notably through the study of the water isotopic composition of polar precipitation (δ18O, δD ). The quest for the highest resolution possible has resulted in experimental sampling and analysis techniques that have yielded data sets with a potential to change the current picture on the climatic signals of the last Glacial. Specifically, the ultra-high resolution δ18O signals from the NorthGRIP and NEEM ice cores, present a variability at multi-annual and decadal time scales, whose interpretation gives rise to further puzzling though interesting questions and an obvious paradox. By means of simple firn isotope diffusion and densification calculations, we firstly demonstrate that the variability of observed signals is unlikely to be due to post depositional effects that are known to occur on the surface of the Greenland ice cap and alter the δ18O composition of the precipitated snow. Assuming specific values for the δ18O sensitivity to temperature (commonly referred to as the δ18O slope), we estimate that the temperature signal during the stadials has a variability that extents from interstadial to extremely cold levels with peak-to-peak fluctuations of almost 35 K occurring in a few years. Similarly, during interstadial phases the temperature varies rapidly from stadial to Holocene levels while the signal variability shows a maximum during the LGM, with magnitudes of up to 15‰ that translate to ≈ 50 K when a δ18O slope of 0.3‰K-1 is used. We assess the validity of these results and comment on the stability of the δ18O slope. Driven by a simple logical queue, we conclude that the observed δ18O variability reflects a climatic signal although not necessarily attributed 100% to temperature changes. From this we can assume that there occur climatic mechanisms during the previously thought stable

  19. Flow analysis of the ophthalmic artery

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Kuniaki; Hashimoto, Masato; Bandoh, Michio; Odawara, Yoshihiro; Kamagata, Masaki; Shirase, Ryuji [Sapporo Medical Univ. (Japan). Hospital

    2003-02-01

    The purpose of this study was to analyze the hemodynamics of ophthalmic artery flow using phase contrast MR angiography (PC-MRA). A total of 14 eyes from 10 normal volunteers and a patient with normal tension glaucoma (NTG) were analyzed. The optimal conditions were time repetition (TR)/echo time (TE)/flip angle (FA)/nex=40 ms/minimum/90 deg/2, field of view (FOV)=6 cm, matrix size=256 x 256. The resistive index (RI) and pulsatillity index (PI) values were significantly raised in the patient with NTG when compared to the control group. We therefore believe that PC-MRA may be a useful clinical tool for the assessment of the mechanism of NTG. (author)

  20. Bioavailability and biochemical effects of diclofenac sodium 0.1% ophthalmic solution in the domestic chicken (Gallus gallus domesticus).

    Science.gov (United States)

    Griggs, Angela N; Yaw, Taylor J; Haynes, Joseph S; Ben-Shlomo, Gil; Tofflemire, Kyle L; Allbaugh, Rachel A

    2017-03-01

    To determine if topical ophthalmic diclofenac sodium 0.1% solution alters renal parameters in the domestic chicken, and to determine if the drug is detectable in plasma after topical ophthalmic administration. Thirty healthy domestic chickens. Over 7 days, six birds were treated unilaterally with one drop of artificial tear solution (group 1), 12 birds were treated unilaterally (group 2) and 12 bilaterally (group 3) with diclofenac sodium 0.1% ophthalmic solution. Treatments were provided every 12 h in all groups. Pre- and post-treatment plasma samples from all birds were evaluated for changes in albumin, total protein, and uric acid. Post-treatment samples of all birds, collected 15 min post-administration, were analyzed by high-performance liquid chromatography with mass spectrometry for diclofenac sodium detection. A randomly selected renal sample from each group was submitted for histopathologic review. Changes in pre- and post-treatment plasma albumin were significant (P Ophthalmic diclofenac sodium 0.1% administered topically every 12 h in one or both eyes for 7 days is detectable in systemic circulation in the domestic chicken, but does not cause overt significant changes in plasma uric acid or total protein. © 2016 American College of Veterinary Ophthalmologists.

  1. Safety comparison of additives in antiglaucoma prostaglandin (PG analog ophthalmic formulations

    Directory of Open Access Journals (Sweden)

    Fukuda M

    2013-03-01

    Full Text Available Masamichi Fukuda, Shinsuke Shibata, Naoko Shibata, Kenta Hagihara, Hiromoto Yaguchi, Hiromi Osada, Nobuo Takahashi, Eri Kubo, Hiroshi SasakiDepartment of Ophthalmology, Kanazawa Medical University, Uchinada, JapanPurpose: To investigate the safety of five types of antiglaucoma prostaglandin analog ophthalmic formulations, and to clarify their differences in accordance with contained additives (preservatives and surface-active agents.Methods: The following five types of ophthalmic solutions and three types of additives were investigated: latanoprost (Xalatan®; latanoprost, tafluprost (Tapros®; tafluprost, bimatoprost (Lumigan®; bimatoprost, travoprost (Travatan®; travoprost, travoprost (Travatan Z®; travoprost-Z, benzalkonium chloride (BAK, polyoxyethylene hardening castor oil 40 (HCO-40, and polysorbate 80 (P-80. These experimental solutions were exposed to the cultured cells of a rabbit-derived corneal cell line for a certain time, and the exposure time causing 50% cell damage (CD50, indicated by the ratio of viable cells to total cells was calculated (in vitro. In addition, corneal resistance (CR was measured and CR ratio (post-treatment CR/pretreatment CR × 100 was calculated (in vivo.Results: CD50 of each ophthalmic solution was the longest with tafluprost, followed by travoprost-Z, bimatoprost, travoprost, and latanoprost. CD50 of 0.005%, 0.01%, and 0.02% BAK was 14.5 minutes, 8.1 minutes, and 4.0 minutes, respectively. The number of viable cells decreased to 60%, 8 minutes after exposure with HCO-40, and 30 minutes after being exposed to P-80. The CR ratio was 81.0% with travoprost and 82.0% with latanoprost, indicating a significant posttreatment reduction of CR (P < 0.05. The CR ratio did not decrease after treatment with tafluprost, travoprost-Z, or bimatoprost. The CR ratio of 0.005%, 0.01%, and 0.02% BAK was 105.0%, 90.5%, and 68.7%, respectively, and that of HCO-40 and P-80 was 108.7% and 114.2%, respectively.Conclusion: BAK

  2. The ALICE TPC, a high resolution device for ultra-high particle multiplicities. Past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Marian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH (Germany); Collaboration: ALICE-Collaboration

    2015-07-01

    The Time Projection Chamber (TPC) of the ALICE apparatus is a large 3-dimensional tracking and particle identification device for ultra-high multiplicity collision events. It has been operated successfully at the Large Hadron Collider (LHC) at CERN, recording data from pp, p-Pb, and Pb-Pb collisions. Presently, LHC is in its first long shutdown (LS1), the next round of data taking will start in summer 2015 at or close to the LHC design energy and luminosity. During the second long shutdown (LS2), LHC will undergo a further increase in the Pb-Pb luminosity together with a major upgrade of ALICE. After the upgrade, the ALICE TPC will operate with Pb-Pb collisions at an interaction rate of 50 kHz. We present the performance in operation, calibration and reconstruction with the ALICE TPC together with ongoing work and plans for the near future and the coming 10 years.

  3. [A case of ophthalmic artery occlusion following injection of hyaluronic acid into the glabellar area].

    Science.gov (United States)

    Nonomura, Sakiko; Oshitari, Toshiyuki; Miura, Gen; Chiba, Akihiro; Yamamoto, Shuichi

    2014-09-01

    We report a case of unilateral blindness due to ophthalmic artery occlusion following injection of hyaluronic acid into the glabellar area for facial soft-tissue augmentation. A 20-year old woman underwent injection of hyaluronic acid into the glabellar area at an aesthetic plastic clinic. Immediately after injection, she suffered nausea, pain, paralysis of limbs and visual loss in her right eye. Hyaluronidase was instanly injected into the same place, but these symptoms did not improve. She was transferred to our hospital's emergency department. At the first examination, she had no light perception in the right eye and her right pupil was dilated. The fundus examination revealed right central artery occlusion. No significant findings were detected in her head. Eye ball massage, hyperbaric oxygen therapy, and drip infusion of urokinase were conducted, but no improvement resulted. Fluorescein and indocyanine green angiography showed no filling of the right retinal and choroidal arteries. Electroretinogram was completely disappeared. Magnetic resonance angiography could not reveal the obstruction point of the ophthalmic artery. Ophthalmic artery occlusion was believed to have occured after injection of hyaluronic acid into the glabellar area.

  4. [Randomized parallel group study of 0.0015% tafluprost ophthalmic solution in patients with primary open-angle glaucoma or ocular hypertension (comparison with 0.005% latanoprost ophthalmic solution)].

    Science.gov (United States)

    Ge, Jian; Li, Xiaoxin; Sun, Xinghuai; He, Xiangge; Zhang, Hong

    2015-02-01

    To confirm the non-inferiority of the IOP-lowering effect of the 0.0015% Tafluprost ophthalmic solution to the 0.005% Latanoprost ophthalmic solution in patients with primary open-angle glaucoma or ocular hypertension.Safety was also compared between two groups. This study was conducted from August 2008 to December 2009, at five clinical trial sites in China. Patients of this study population was diagnosed with primary open-angle glaucoma or ocular hypertension in both eyes.Subjects were randomized into 0.0015% Tafluprost group or 0.005% Latanoprost group.Intraocular pressure (IOP) measurement by Goldmann applanation tonometer, slit-lamp microscopy, Gonioscopy, Fundascopy, Visual acuity test, Perimetry, Blood pressure and pulse rate, Subjective symptoms were compered between two groups at Week 0, Week 2 and Week 4.For main effectiveness evaluation index adopt the bad effect evaluation, safety evaluation index by Fisher's exact test probability method. The 246 subjects/246 eyes were randomized (Tafluprost group:122 subjects/122 eyes, Latanoprost group:124 subjects/ 124 eyes). Change in the IOP at 17:00 of Week 2 is (8.8 ± 3.8) mmHg and (8.9 ± 4.4) mmHg (1 mmHg = 0.133 kPa) in Tafluprost group and Latanoprost group. Percent change in the IOP at 17:00 of Week 2 is (33.2 ± 12.8)% and (34.4 ± 14.1)% in Tafluprost group and Latanoprost group. Change in the IOP at 17:00 at the end of treatment is (9.8 ± 4.0) mmHg and (9.2 ± 4.1) mmHg in Tafluprost group and Latanoprost group. Percent change in the IOP at 17:00 at the end of treatment is 37.2% ± 13.4% group and 35.7% ± 13.0% in Tafluprost and Latanoprost group.In addition, distribution of subjects with percentage decrease of IOP > 30% was 72.5% in Tafluprost group higher than 63.8% in Latanoprost group. The major adverse reactions were conjunctival hyperemia, eye irritation, eye pain and foreign body sensation. The incidence of adverse reactions is 31.7% in Tafluprost group and 20.8% in Latanoprost group. The inter

  5. Progesterone increases resistance of ophthalmic and central retinal arteries in climacteric women.

    Science.gov (United States)

    Souza, M A M De; Souza, B M De; Geber, S

    2013-04-01

    To evaluate the effect of a synthetic progestin on the vascular resistance of the ophthalmic and central retinal arteries in climacteric women, compared to placebo, using transorbital ultrasound with Doppler velocimetry. We performed a prospective, randomized, double-blinded, placebo-controlled study with 216 climacteric women. Subjects were randomly allocated to one of two groups: either the group receiving placebo (one pill/day for 30 days) (n = 108) or the group receiving progestin (5 mg medroxyprogesterone acetate/day for 30 days) (n = 108). Transorbital Doppler velocimetric ultrasound was performed, before and after treatment; we measured the pulsatility index, resistance index and systole/diastole ratio. The mean ages of the participants in the study group and the control group were 54 ± 6.2 years (range 48-59 years) and 55 ± 6.8 years (range 46-60 years), respectively. When we compared the effect of the progestin on the central retinal artery before and after treatment, we observed a significant increase after the treatment in all Doppler indices. The same was observed when we compared the effect of the progestin on the ophthalmic artery. In the group of women receiving placebo, the Doppler indices were similar before and after treatment. Our results demonstrate the existence of a progestogenic vasoconstrictive effect in the ophthalmic and central retinal arteries. As this study provides new data, the observed effect needs further investigations to better elucidate its extent. Moreover, our findings may be particularly useful to others interested in understanding the vascular dynamics of the cerebral vessels and to researchers running clinical trials related to hormone replacement therapy.

  6. Length-extension resonator as a force sensor for high-resolution frequency-modulation atomic force microscopy in air.

    Science.gov (United States)

    Beyer, Hannes; Wagner, Tino; Stemmer, Andreas

    2016-01-01

    Frequency-modulation atomic force microscopy has turned into a well-established method to obtain atomic resolution on flat surfaces, but is often limited to ultra-high vacuum conditions and cryogenic temperatures. Measurements under ambient conditions are influenced by variations of the dew point and thin water layers present on practically every surface, complicating stable imaging with high resolution. We demonstrate high-resolution imaging in air using a length-extension resonator operating at small amplitudes. An additional slow feedback compensates for changes in the free resonance frequency, allowing stable imaging over a long period of time with changing environmental conditions.

  7. 21 CFR 524.1662b - Oxytetracycline hydrochloride, polymyxin B sulfate ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride, polymyxin B sulfate... DOSAGE FORM NEW ANIMAL DRUGS § 524.1662b Oxytetracycline hydrochloride, polymyxin B sulfate ophthalmic ointment. (a) Specifications. Each gram of the ointment contains oxytetracycline hydrochloride equivalent...

  8. Association between Ophthalmic Timolol and Hospitalisation for Bradycardia

    Directory of Open Access Journals (Sweden)

    Nicole L. Pratt

    2015-01-01

    Full Text Available Introduction. Ophthalmic timolol, a topical nonselective beta-blocker, has the potential to be absorbed systemically which may cause adverse cardiovascular effects. This study was conducted to determine whether initiation of ophthalmic timolol was associated with an increased risk of hospitalisation for bradycardia. Materials and Methods. A self-controlled case-series study was undertaken in patients who were hospitalised for bradycardia and were exposed to timolol. Person-time after timolol initiation was partitioned into risk periods: 1–30 days, 31–180 days, and >180 days. A 30-day risk period prior to initiating timolol was also included. All remaining time was considered unexposed. Results. There were 6,373 patients with at least one hospitalisation for bradycardia during the study period; 267 were exposed to timolol. Risk of bradycardia was significantly increased in the 31–180 days after timolol initiation (incidence rate ratio (IRR = 1.93; 95% confidence interval (CI 1.00–1.87. No increased risk was observed in the first 30 days or beyond 180 days of continuous exposure (IRR = 1.40; 95% CI 0.87–2.26 and IRR = 1.21; 95% CI 0.64–2.31, resp.. Conclusion. Bradycardia is a potential adverse event following timolol initiation. Practitioners should consider patient history before choosing a glaucoma regime and closely monitor patients after treatment initiation with topical nonselective beta-blocker eye drops.

  9. Mydriatics release from solid and semi-solid ophthalmic formulations using different in vitro methods.

    Science.gov (United States)

    Pescina, Silvia; Macaluso, Claudio; Gioia, Gloria Antonia; Padula, Cristina; Santi, Patrizia; Nicoli, Sara

    2017-09-01

    The aim of the present paper was the development of semi-solid (hydrogels) and solid (film) ophthalmic formulations for the controlled release of two mydriatics: phenylephrine and tropicamide. The formulations - based on polyvinylalcohol and hyaluronic acid - were characterized, and release studies were performed with three different in vitro set-ups, i.e. Franz-type diffusion cell, vial method and inclined plane; for comparison, a solution and a commercial insert, both clinically used to induce mydriasis, were evaluated. Both gels and film allowed for a controlled release of drugs, appearing a useful alternative for mydriatics administration. However, the release kinetic was significantly influenced by the method used, highlighting the need for optimization and standardization of in vitro models for the evaluation of drug release from ophthalmic dosage forms.

  10. Feature Screening for Ultrahigh Dimensional Categorical Data with Applications.

    Science.gov (United States)

    Huang, Danyang; Li, Runze; Wang, Hansheng

    2014-01-01

    Ultrahigh dimensional data with both categorical responses and categorical covariates are frequently encountered in the analysis of big data, for which feature screening has become an indispensable statistical tool. We propose a Pearson chi-square based feature screening procedure for categorical response with ultrahigh dimensional categorical covariates. The proposed procedure can be directly applied for detection of important interaction effects. We further show that the proposed procedure possesses screening consistency property in the terminology of Fan and Lv (2008). We investigate the finite sample performance of the proposed procedure by Monte Carlo simulation studies, and illustrate the proposed method by two empirical datasets.

  11. Ultrahigh-energy particles from cosmic strings

    International Nuclear Information System (INIS)

    Bhattacharjee, P.

    1991-02-01

    The idea of production of ultrahigh-energy particles in the present universe due to annihilation or collapse of topological defects is discussed. Topological defects, formed in symmetry-breaking phase transitions in the early universe, can survive till today owing to their topological stability. However, under certain circumstances, topological defects may be physically destroyed. When topological defects are destroyed, the energy contained in the defects can be released in the form of massive gauge- and Higgs bosons of the underlying spontaneously broken gauge theory. Subsequent decay of these massive particles can give rise to energetic particles ranging up to an energy on the order of the mass of the original particles released from the defects. This may give us a ''natural'' mechanism of production of extremely energetic cosmic ray particles in the universe today, without the need for any acceleration mechanism. To illustrate this idea, I describe in detail the calculation of the expected ultrahigh-energy proton spectrum due to a specific process which involves collapse or multiple self-intersections of a class of closed cosmic string loops formed in a phase transition at a grand unification energy scale. I discuss the possibility that some of the highest-energy cosmic ray particles are of this origin. By comparing with the observational results on the ultrahigh-energy cosmic rays, we derive an upper limit to the average fraction of the total energy in all ''primary'' cosmic string loops that may be released in the form of particles due to collapse or multiple self-intersections of these loops. No nuclei such as α's or Fe's are in the spectrum. 43 refs., 3 figs

  12. Clinical utility of 3% diquafosol ophthalmic solution in the treatment of dry eyes

    Directory of Open Access Journals (Sweden)

    Koh S

    2015-05-01

    Full Text Available Shizuka Koh Department of Ophthalmology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan Abstract: Diquafosol is a drug used for dry eye treatment with a novel mechanism of action. It stimulates the secretion of tear fluid and mucin on the ocular surface, thus enabling us to selectively treat the tear film layer, playing an important role in the establishment of the concept of “Tear Film Oriented Therapy (TFOT”, an effective therapeutic approach to dry eye in Japan. The 3% diquafosol ophthalmic solution has been widely used for the treatment of dry eye in clinical practice, and it is currently available in Japan and South Korea. This review provides an overview of the clinical utility of 3% diquafosol ophthalmic solution, focusing on the results of clinical studies on various types of dry eye, including aqueous-deficient dry eye, short tear film breakup time-type dry eye, and post dry eye after laser in situ keratomileusis. It also introduces the additive effect of diquafosol on sodium hyaluronate monotherapy for dry eye, and the effect of 3% diquafosol ophthalmic solution for dry eye-related conditions. Additionally, it summarizes the ocular effects of diquafosol in healthy human eyes. Lastly, the importance of improving tear film stability in dry eye treatment, as well as general advances in dry eye treatments, are described. Keywords: diquafosol, dry eye, mucin secretion, fluid secretion, ocular surface, vision

  13. Laser tissue welding in ophthalmic surgery.

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2008-09-01

    Laser welding of ocular tissues is an alternative technique or adjunct to conventional suturing in ophthalmic surgery. It is based on the photothermal interaction of laser light with the main components of the extracellular matrix of connective tissues. The advantages of the welding procedure with respect to standard suturing and stapling are reduced operation times, lesser inflammation, faster healing and increased ability to induce tissue regeneration. The procedure we set up is based on the use of an infrared diode laser in association with the topical application of the chromophore Indocyanine Green. Laser light may be delivered either continuously or in pulses, thus identifying two different techniques that have been applied clinically in various types of transplants of the cornea.

  14. Ophthalmic compensation of visual ametropia based on a programmable diffractive lens

    Science.gov (United States)

    Millán, Maria S.; Pérez-Cabré, Elisabet; Romero, Lenny A.; Ramírez, Natalia

    2013-11-01

    Pixelated liquid crystal displays have been widely used as spatial light modulators to implement programmable diffractive optical elements (DOEs), particularly diffractive lenses. Many different applications of such components have been developed in information optics and optical processors that take advantage of their properties of great flexibility, easy and fast refreshment, and multiplexing capability in comparison with equivalent conventional refractive lenses. In this paper, we explore the application of programmable diffractive lenses displayed on the pixelated screen of a liquid crystal on silicon spatial light modulator (LCoS-SLM) to ophthalmic optics. In particular, we consider the use of programmable diffractive lenses for the visual compensation of some refractive errors (myopia, hyperopia). The theoretical principles of compensation are described and sketched using geometrical optics and paraxial ray tracing. A series of experiments with artificial eye in optical bench are conducted to analyze the compensation accuracy in terms of optical power and to compare the results with those obtained by means of conventional ophthalmic lenses. Practical considerations oriented to feasible applications are provided.

  15. Endovascular Treatment of Persistent Epistaxis due to Pseudoaneurysm Formation of the Ophthalmic Artery Secondary to Nasogastric Tube

    Energy Technology Data Exchange (ETDEWEB)

    Selcuk, Hakan, E-mail: hakanselcuk73@yahoo.com; Soylu, Nur; Albayram, Sait; Selcuk, Dogan; Ozer, Harun; Kocer, Naci; Islak, Civan [Cerrahpasa Medical School, Istanbul University, Department of Radiology, Division of Neuroradiology (Turkey)

    2005-04-15

    We present the case of a 60-year-old man with persistent epistaxis for 20 days that had started 2 weeks after removal of a nasogastric tube placed for an abdominal operation. There was no pathologic finding at selective facial and internal maxillary artery injections. An injury to the ethmoidal branches of the ophthalmic arteries or other arterial origins of bleeding was suspected. The internal carotid artery angiography revealed a pseudoaneurysm of an anterior ethmoidal branch of the left ophthalmic artery. The pseudoaneurysm was occluded with NBCA-histoacryl (25%) injection.

  16. Endovascular Treatment of Persistent Epistaxis due to Pseudoaneurysm Formation of the Ophthalmic Artery Secondary to Nasogastric Tube

    International Nuclear Information System (INIS)

    Selcuk, Hakan; Soylu, Nur; Albayram, Sait; Selcuk, Dogan; Ozer, Harun; Kocer, Naci; Islak, Civan

    2005-01-01

    We present the case of a 60-year-old man with persistent epistaxis for 20 days that had started 2 weeks after removal of a nasogastric tube placed for an abdominal operation. There was no pathologic finding at selective facial and internal maxillary artery injections. An injury to the ethmoidal branches of the ophthalmic arteries or other arterial origins of bleeding was suspected. The internal carotid artery angiography revealed a pseudoaneurysm of an anterior ethmoidal branch of the left ophthalmic artery. The pseudoaneurysm was occluded with NBCA-histoacryl (25%) injection

  17. High resolution anatomical and quantitative MRI of the entire human occipital lobe ex vivo at 9.4 T

    NARCIS (Netherlands)

    Sengupta, S.; Lagos Fritz, F.J.; Harms, R.L.; Hildebrand, S.; Tse, D.H.Y.; Poser, B.A.; Goebel, R.; Roebroeck, A.

    Several magnetic resonance imaging (MRI) contrasts are sensitive to myelin content in gray matter in vivo which has ignited ambitions of MRI-based in vivo cortical histology. Ultra-high field (UHF) MRI, at fields of 7 T and beyond, is crucial to provide the resolution and contrast needed to sample

  18. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  19. Efficacy and safety of diquafosol ophthalmic solution in patients with dry eye syndrome: a Japanese phase 2 clinical trial.

    Science.gov (United States)

    Matsumoto, Yukihiro; Ohashi, Yuichi; Watanabe, Hitoshi; Tsubota, Kazuo

    2012-10-01

    To investigate the dose-dependent efficacy and safety of diquafosol ophthalmic solution for the treatment of dry eye syndrome. Randomized, double-masked, multicenter, parallel-group, placebo-controlled trial. A total of 286 Japanese patients with dry eye who were prescribed topical diquafosol (1%, n = 96; 3%, n = 96) or placebo ophthalmic solution (n = 94). After a washout period of 2 weeks, qualified subjects were randomized to receive a single drop of 1% or 3% diquafosol or placebo ophthalmic solutions 6 times per day for 6 weeks. The primary outcome measure was fluorescein corneal staining score assessment. The secondary outcome measures were Rose Bengal corneal and conjunctival staining scores, tear break-up time (BUT), and subjective symptom assessment. Safety measures were clinical blood and urine examination and recording of adverse events. Fluorescein corneal staining scores significantly improved with both 1% and 3% topical diquafosol compared with placebo at 4 weeks, respectively (P = 0.037, P = 0.002). There was a dose-dependent effect among the groups. Rose Bengal corneal and conjunctival staining scores also improved significantly with both 1% and 3% diquafosol compared with placebo (P = 0.007 and P = 0.004, respectively). Subjective dry eye symptom scores significantly improved with both diquafosol ophthalmic solutions (P ≤ 0.033), although there were no significant differences in BUT compared with placebo. No significant differences between the treatment groups were observed in relation to the occurrence of adverse events. Both 1% and 3% diquafosol ophthalmic solutions are considered effective and safe for the treatment of dry eye syndrome. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Scientific publications in ophthalmic journals from China and other top-ranking countries: a 12-year review of the literature.

    Science.gov (United States)

    Huang, Wenbin; Wang, Wei; Zhan, Jiao; Zhou, Minwen; Chen, Shida; Zhang, Xiulan

    2013-06-26

    Eye diseases with increasing mortality are common health problems that affect people of all ages and demographic backgrounds. In this study, we study the publication characteristics in international ophthalmic journals of the US, the UK, Germany, Australia, Japan, and China. Articles published in 53 ophthalmic journals from 2000 to 2011 were retrieved from the PubMed database. We recorded the number of articles published each year, analyzed the publication type, and evaluated the accumulated and average impact factors (IFs), and the distribution of articles in ophthalmic journals in relation to IFs. The characteristics of publication outputs from China and other top-ranking countries were compared. The total number of articles increased significantly during the past 12 years, with an increase of 51.0%. The growth in the annual number of articles from the US, the UK, Australia, and China showed a significantly positive trend. Publications from the US exceeded those from any other country and had the highest IFs, largest number of total citations of articles, and the most articles published in leading ophthalmic journals. During the past 12 years, China contributed 3.5% of the total publications, and the number of Chinese articles showed a more than 6-fold increase (from 99 to 605, R2 =0.947, P<0.001). The numbers of IFs and citations of articles originating in China were mostly lower than for other top-ranking counties. Research on ophthalmic journals has maintained an upward growing trend from 2000 to 2011. Chinese ophthalmology research has developed rapidly, but the gap still exists between China and other top-ranking countries for the advanced level of research.

  1. Constraining sources of ultrahigh energy cosmic rays and shear acceleration mechanism of particles in relativistic jets

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ruoyu

    2015-06-10

    Ultrahigh energy cosmic rays are extreme energetic particles from outer space. They have aroused great interest among scientists for more than fifty years. However, due to the rarity of the events and complexity of the process of their propagation to Earth, they are still one of the biggest puzzles in modern high energy astrophysics. This dissertation is dedicated to study the origin of ultrahigh energy cosmic rays from various aspects. Firstly, we discuss a possible link between recently discovered sub-PeV/PeV neutrinos and ultrahigh energy cosmic rays. If these two kinds of particles share the same origin, the observation of neutrinos may provide additional and non-trivial constraints on the sources of ultrahigh energy cosmic rays. Secondly, we jointly employ the chemical composition measurement and the arrival directions of ultrahigh energy cosmic rays, and find a robust upper limit for distances of sources of ultrahigh energy cosmic rays above ∝55 EeV, as well as a lower limit for their metallicities. Finally, we study the shear acceleration mechanism in relativistic jets, which is a more efficient mechanism for the acceleration of higher energy particle. We compute the acceleration efficiency and the time-dependent particle energy spectrum, and explore the feature of synchrotron radiation of the accelerated particles. The possible realizations of this mechanism for acceleration of ultrahigh energy cosmic rays in different astrophysical environments is also discussed.

  2. Expectations for ultra-high energy interactions

    International Nuclear Information System (INIS)

    Feynman, R.P.

    1978-01-01

    Strong interactions at ultra-high energies are discussed with emphasis on the hadrons produced in high energy collisions. Evidence is considered that quantum chromodynamics might be the right theory, and also some estimates are given of quantum chromodynamics asymptotic-freedom phenomena, the work under discussion being very preliminary. 6 references

  3. Immediate Effects of 3% Diquafosol and 0.1% Hyaluronic Acid Ophthalmic Solution on Tear Break-Up Time in Normal Human Eyes.

    Science.gov (United States)

    Nam, Ki Tae; Ahn, So Min; Eom, Youngsub; Kim, Hyo Myung; Song, Jong Suk

    2015-12-01

    The purpose of this study was to evaluate the immediate effect of 3% diquafosol ophthalmic solution on tear break-up time (TBUT) in normal human eyes, and to compare it with that of saline and 0.1% hyaluronate ophthalmic solution. Cross sectional comparative study in the first study, 10 healthy volunteers underwent topical application of 2 different ophthalmic solutions in each eye. Saline was randomly applied to one eye and 3% diquafosol ophthalmic solution was added to the fellow eye. TBUT was measured and video recorded before application and at 5, 10, 15, and 20 min after. The TBUT in each eye was compared at each time point with regard to the 2 different ophthalmic solutions. In the second study, another 10 healthy volunteers were included. The same methods were used to compare the immediate effects of 0.1% hyaluronate and 3% diquafosol ophthalmic solution application on TBUT. In the first study, topical instillation of saline did not increase TBUT. However, 3% diquafosol significantly increased TBUT for up to 15 min after application. At every time point, the TBUT increased more significantly from baseline in the diquafosol group than it did in the saline group. In the second study, 0.1% hyaluronate increased TBUT for up to 5 min after application, while 3% diquafosol increased TBUT for up to 15 min. Although the TBUT changes after 5 min were not significantly different between the 2 groups, the TBUT changes at 10, 15, and 20 min were significantly greater in the 3% diquafosol group than they were in the 0.1% hyaluronic acid group (+1.58 ± 0.82 vs. +0.53 ± 1.36 at 10 min, +0.67 ± 0.91 vs. -0.04 ± 1.29 at 15 min, and -0.06 ± 0.96 vs. -0.59 ± 0.90, diquafosol group vs. hyaluronic acid group). One drop of 3% diquafosol increased TBUT for up to 15 min after application. The immediate effect of 3% diquafosol on TBUT was greater than that of saline and even that of 1% hyaluronate ophthalmic solution.

  4. Atomic resolution crystal structure of Sapp2p, a secreted aspartic protease from Candida parapsilosis

    Czech Academy of Sciences Publication Activity Database

    Dostál, Jiří; Pecina, Adam; Hrušková-Heidingsfeldová, Olga; Marečková, L.; Pichová, Iva; Řezáčová, Pavlína; Lepšík, Martin; Brynda, Jiří

    2015-01-01

    Roč. 71, č. 12 (2015), s. 2494-2504 ISSN 1399-0047 R&D Projects: GA ČR(CZ) GA14-23022S Institutional support: RVO:61388963 ; RVO:68378050 Keywords : aspartic protease * Candida parapsilosis * Sapp2p * crystal structure * ultrahigh resolution * interaction energy * quantum mechanics Subject RIV: CE - Biochemistry; EB - Genetics ; Molecular Biology (UMG-J) Impact factor: 2.674, year: 2014

  5. Ultrahigh speed endoscopic optical coherence tomography for gastroenterology.

    Science.gov (United States)

    Tsai, Tsung-Han; Lee, Hsiang-Chieh; Ahsen, Osman O; Liang, Kaicheng; Giacomelli, Michael G; Potsaid, Benjamin M; Tao, Yuankai K; Jayaraman, Vijaysekhar; Figueiredo, Marisa; Huang, Qin; Cable, Alex E; Fujimoto, James; Mashimo, Hiroshi

    2014-12-01

    We describe an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor imaging catheter. The system had a 600 kHz axial scan rate and 8 µm axial resolution in tissue. Imaging was performed with a 3.2 mm diameter imaging catheter at 400 frames per second with a 12 µm spot size. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing upper and lower endoscopy. The use of distally actuated imaging catheters enabled OCT imaging with more flexibility, such as volumetric imaging in the small intestine and the assessment of hiatal hernia using retroflex imaging. The high rotational scanning stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face OCT and cross-sectional imaging, as well as OCT angiography (OCTA) for 3D visualization of subsurface microvasculature. The ability to perform both structural and functional 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies and enhance the sensitivity and specificity of OCT for detecting pathology.

  6. Functional magnetic resonance microscopy at single-cell resolution in Aplysia californica

    Science.gov (United States)

    Radecki, Guillaume; Nargeot, Romuald; Jelescu, Ileana Ozana; Le Bihan, Denis; Ciobanu, Luisa

    2014-01-01

    In this work, we show the feasibility of performing functional MRI studies with single-cell resolution. At ultrahigh magnetic field, manganese-enhanced magnetic resonance microscopy allows the identification of most motor neurons in the buccal network of Aplysia at low, nontoxic Mn2+ concentrations. We establish that Mn2+ accumulates intracellularly on injection into the living Aplysia and that its concentration increases when the animals are presented with a sensory stimulus. We also show that we can distinguish between neuronal activities elicited by different types of stimuli. This method opens up a new avenue into probing the functional organization and plasticity of neuronal networks involved in goal-directed behaviors with single-cell resolution. PMID:24872449

  7. Formulation and process factors influencing product quality and in vitro performance of ophthalmic ointments.

    Science.gov (United States)

    Xu, Xiaoming; Al-Ghabeish, Manar; Rahman, Ziyaur; Krishnaiah, Yellela S R; Yerlikaya, Firat; Yang, Yang; Manda, Prashanth; Hunt, Robert L; Khan, Mansoor A

    2015-09-30

    Owing to its unique anatomical and physiological functions, ocular surface presents special challenges for both design and performance evaluation of the ophthalmic ointment drug products formulated with a variety of bases. The current investigation was carried out to understand and identify the appropriate in vitro methods suitable for quality and performance evaluation of ophthalmic ointment, and to study the effect of formulation and process variables on its critical quality attributes (CQA). The evaluated critical formulation variables include API initial size, drug percentage, and mineral oil percentage while the critical process parameters include mixing rate, temperature, time and cooling rate. The investigated quality and performance attributes include drug assay, content uniformity, API particle size in ointment, rheological characteristics, in vitro drug release and in vitro transcorneal drug permeation. Using design of experiments (DoE) as well as a novel principle component analysis approach, five of the quality and performance attributes (API particle size, storage modulus of ointment, high shear viscosity of ointment, in vitro drug release constant and in vitro transcorneal drug permeation rate constant) were found to be highly influenced by the formulation, in particular the strength of API, and to a lesser degree by processing variables. Correlating the ocular physiology with the physicochemical characteristics of acyclovir ophthalmic ointment suggested that in vitro quality metrics could be a valuable predictor of its in vivo performance. Published by Elsevier B.V.

  8. Electron beam excitation assisted optical microscope with ultra-high resolution.

    Science.gov (United States)

    Inami, Wataru; Nakajima, Kentaro; Miyakawa, Atsuo; Kawata, Yoshimasa

    2010-06-07

    We propose electron beam excitation assisted optical microscope, and demonstrated its resolution higher than 50 nm. In the microscope, a light source in a few nanometers size is excited by focused electron beam in a luminescent film. The microscope makes it possible to observe dynamic behavior of living biological specimens in various surroundings, such as air or liquids. Scan speed of the nanometric light source is faster than that in conventional near-field scanning optical microscopes. The microscope enables to observe optical constants such as absorption, refractive index, polarization, and their dynamic behavior on a nanometric scale. The microscope opens new microscopy applications in nano-technology and nano-science.

  9. Application of ophthalmic ultrasonographyin DR

    Directory of Open Access Journals (Sweden)

    Ya-Ke Li

    2018-02-01

    Full Text Available AIM: To investigate the value of ultrasonography in diabetic retinopathy(DR. METHODS: Totally 103 cases(103 eyesof type 2 diabetes mellitus were selected from May 2015 to May 2017 in our hospital, there were 32 patients 32 eyes with non diabetic retinopathy(NDR, 40 patients 40 eyes with non proliferative diabetic retinopathy(NPDR, and 31 patients 31 eyes with proliferative diabetic retinopathy(PDR, 40 healthy volunteers(40 eyeswere selected as control group, the maximum systolic blood flow velocity(PSV, end diastolic velocity(EDVand resistance index(RIof the central retinal artery(CRA, posterior ciliary artery(PCAand ophthalmic artery(OAwere detected by color Doppler ultrasound. RESULTS: The difference of PSV, EDV and RI of CRA, PCA and OA in each group was statistically significant(PPPPCONCLUSION: Color Doppler ultrasound monitoring the hemodynamic changes of ocular blood vessels in diabetes can provide evidence for early detection of diabetic retinopathy.

  10. Integrated analysis of three bacterial conjunctivitis trials of besifloxacin ophthalmic suspension, 0.6%: microbiological eradication outcomes

    Directory of Open Access Journals (Sweden)

    Morris TW

    2011-09-01

    Full Text Available Timothy W Morris1, Lynne S Gearinger1, Dale W Usner2, Michael R Paterno2, Heleen H DeCory3, Timothy L Comstock3, Wolfgang Haas11Microbiology and Sterilization Sciences, 2Clinical Affairs, 3Global Pharmaceutical Medical Affairs, Bausch & Lomb, Rochester, NY, USAPurpose: To assess clinical antimicrobial efficacy results obtained with besifloxacin ophthalmic suspension, 0.6%, administered three times a day (TID for 5 days, integrated across three clinical trials of bacterial conjunctivitis and to investigate any microbiological eradication failures.Methods: Clinical microbiological eradication data from three randomized, double-masked, parallel group studies of patients with bacterial conjunctivitis (two vehicle controlled; one active controlled with moxifloxacin ophthalmic solution, 0.5% were integrated. All bacterial samples isolated at baseline above the species-specific threshold value were subjected to antimicrobial susceptibility testing. Samples isolated at subsequent visits were subjected to susceptibility testing and pulsed-field gel electrophoresis (PFGE to investigate the cause of eradication failures and the potential for drug resistance development.Results: Visit 2 (day 4 or 5 and visit 3 (day 8 overall microbiological eradication rates were 92.2% and 88.4% for besifloxacin ophthalmic suspension compared with 61.4% and 72.5% for vehicle and 91.6% and 85.7% for moxifloxacin ophthalmic solution. Visit 2 and visit 3 microbiological eradication rates for Gram-positive and Gram-negative isolates and for individual species were consistent with the overall eradication rates. The majority of observed eradication failures in any treatment group were due to the persistence of the pathogen isolated at baseline. Eradication failures in the besifloxacin treatment group were not associated with lower antimicrobial susceptibility at baseline. PFGE data showed that the majority of bacterial strains in eyes with eradication failures were identical to

  11. Neuro-ophthalmic and clinical characteristics of brain tumours in a tertiary hospital in Ghana

    International Nuclear Information System (INIS)

    Tagoe, N. N.; Essuman, V. A.; Fordjuor, G.; Akpalu, J.; Bankah, P.; Ndanu, T.

    2015-01-01

    Anecdotally, increasing number of patients are seen at Korle Bu Teaching Hospital (KBTH) with brain tumour. Neuro-ophthalmic symptoms and signs may help in timely diagnosis and intervention. The objective of this study is to evaluate the neuro-ophthalmic and clinical characteristics of brain tumour in patients presenting at a tertiary hospital in Ghana. The study design involved a prospective case series involving 36 consecutive patients newly diagnosed with brain tumour from November 2010 to October 2011, at the Ophthalmology, Neurosurgery and Endocrine units of KBTH, Ghana. All patients had clinical diagnosis of brain tumour with confirmation by computerized tomography (CT) or magnetic resonance imaging (MRI). Thirteen patients had histological confirmation of diagnosis. The outcome measures of the study include presenting visual acuity, colour vision, visual fields and cranial nerve deficits. Data of 36 patients were analysed. The results of the study showed that ages ranged from 3 to 69 years, mean (SD) 42.56(±16.6 years). Twenty-six (72%) were females. Tumours included pituitary adenoma (20, 55.5%), meningioma (10, 27.8%), choroid plexus tumour (1, 2.8%), medulloblastom (1, 2.8%), craniopharyngioma (1, 2.8%), haemangioblastoma (1, 2.8%), thalamic tumour (1, 2.8%) and haemangioma (1, 2.8%). Histologically confirmed tumours included pituitary adenoma (9, 69.2%), meningioma (3, 23.1%), craniopharyngioma (1, 7.7%). One patient had both a pituitary adenoma and meningioma. Blurred vision (30, 83.3%), headache (28, 77.8%) and photophobia (13, 36.1%) were predominant symptoms. Commonest neuro-ophthalmic signs were impaired colour vision (62 eyes, 88.6%), optic atrophy (26, 74.3%), unilateral or bitemporal hemianopia (15, 41.5%) and relative afferent pupillary defect (12, 34.3%). Seven (19.4%) patients were visually impaired and nine (25%) blind. Thirty-three of 72(45.8%) eyes had monocular blindness. Common neuro-ophthalmic characteristics were blurred vision

  12. Ultra-high resolution X-ray structures of two forms of human recombinant insulin at 100 K.

    Science.gov (United States)

    Lisgarten, David R; Palmer, Rex A; Lobley, Carina M C; Naylor, Claire E; Chowdhry, Babur Z; Al-Kurdi, Zakieh I; Badwan, Adnan A; Howlin, Brendan J; Gibbons, Nicholas C J; Saldanha, José W; Lisgarten, John N; Basak, Ajit K

    2017-08-01

    with the Insugen (I) structure. In the Intergen (II) structure there is no solvated propanol or acetate molecule. The electron density of Intergen (II), however, does also exhibit the three types of amino acid representations as in Insugen (I). These effects do not necessarily correspond between chains A and C or chains B and D in Intergen (II), or between corresponding residues in Insugen (I). The results of this comparison are reported. Graphical abstract Conformations of PheB25 and PheD25 in three insulin structures: implications for biological activity? Insulin residues PheB25 and PheD25 are considered to be important for insulin receptor binding and changes in biological activity occur when these residues are modified. In porcine insulin and Intergen (II) PheB25 adopts conformation B and PheD25 conformation D. However, unexpectedly PheB25 in Insugen (I) human recombinant insulin adopts two distinct conformations corresponding to B and D, Figure 1 and PheD25 adopts a single conformation corresponding to B not D, Figure 2. Conformations of this residue in the ultra-high resolution structure of Insugen (I) are therefore unique within this set. Figures were produced with Biovia, Discovery Studio 2016.

  13. Magnetic Microcalorimeters with Ultra-High Energy Resolution (FY17 Q2 report)

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ramos, Chris [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-08-28

    We will continue to characterize the Ag:Er MMC in detail to compare it with existing models and understand its limiting performance, both in New Mexico and at LLNL. For best resolution, it will be important to reduce external electromagnetic interference and ensure good thermal coupling to the cryostat. Improved resolution will be important for our presentations at the LTD-17 conference in Japan in Q3. We have also hired Cameron Flynn, a junior in physics at the university of New Hampshire, as a summer student to work on the MMC detector project. If he turns out to be as smart and as strong in the lab as his letters of recommendation and his interview performance suggests, we will try to attract him into one of the bay area universities for his Ph.D. and recruit him to LLNL for his thesis research.

  14. Determination of permeability coefficients of ophthalmic drugs through different layers of porcine, rabbit and bovine eyes.

    Science.gov (United States)

    Loch, Christian; Zakelj, Simon; Kristl, Albin; Nagel, Stefan; Guthoff, Rudolf; Weitschies, Werner; Seidlitz, Anne

    2012-08-30

    To treat ophthalmic diseases like glaucoma or inflammatory disorders topically applied ophthalmic formulations such as eye drops are usually used. In addition, novel ophthalmic implants releasing drug substances locally into different parts of the eye are available today. In the work presented here, the permeability coefficients of selected drugs (ciprofloxacin hydrochloride, lidocaine hydrochloride, timolol maleate) for ophthalmic tissues were determined using side-by-side diffusion chambers (so-called Ussing chambers). Sclera, conjunctiva, cornea, choroidea-retina-complex and a complex of conjunctiva-sclera-choroidea-retina were excised from fresh porcine, rabbit and bovine eyes. In the porcine eye tissues the highest P(app) values were obtained for conjunctiva with the exception of lidocaine. Therefore, it can be estimated that a certain amount of drug diffuses or is transported through conjunctiva after application. The P(app) values for sclera were also higher than those for cornea and even more, the surface area of sclera which is available for drug absorption is much larger than that of cornea when applying an implant. The obtained permeability coefficients for sclera and conjunctiva indicate that the administration of periocular implants can be an alternative to topically applied formulations. The complexes of the tissues were a significantly (p<0.01) stronger barrier to the investigated substances than the separated tissues. Distinct differences in permeability coefficients between the investigated animal tissues were observed. Overall the highest P(app) values for all mounted tissues were obtained with the rabbit, followed by porcine and bovine eyes. Because of these distinct interspecies differences one must be very careful when selecting the proper animal model for the permeability experiments. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Ultra-high resolution HLA genotyping and allele discovery by highly multiplexed cDNA amplicon pyrosequencing

    Directory of Open Access Journals (Sweden)

    Lank Simon M

    2012-08-01

    Full Text Available Abstract Background High-resolution HLA genotyping is a critical diagnostic and research assay. Current methods rarely achieve unambiguous high-resolution typing without making population-specific frequency inferences due to a lack of locus coverage and difficulty in exon-phase matching. Achieving high-resolution typing is also becoming more challenging with traditional methods as the database of known HLA alleles increases. Results We designed a cDNA amplicon-based pyrosequencing method to capture 94% of the HLA class I open-reading-frame with only two amplicons per sample, and an analogous method for class II HLA genes, with a primary focus on sequencing the DRB loci. We present a novel Galaxy server-based analysis workflow for determining genotype. During assay validation, we performed two GS Junior sequencing runs to determine the accuracy of the HLA class I amplicons and DRB amplicon at different levels of multiplexing. When 116 amplicons were multiplexed, we unambiguously resolved 99%of class I alleles to four- or six-digit resolution, as well as 100% unambiguous DRB calls. The second experiment, with 271 multiplexed amplicons, missed some alleles, but generated high-resolution, concordant typing for 93% of class I alleles, and 96% for DRB1 alleles. In a third, preliminary experiment we attempted to sequence novel amplicons for other class II loci with mixed success. Conclusions The presented assay is higher-throughput and higher-resolution than existing HLA genotyping methods, and suitable for allele discovery or large cohort sampling. The validated class I and DRB primers successfully generated unambiguously high-resolution genotypes, while further work is needed to validate additional class II genotyping amplicons.

  16. Correlation of ophthalmic examination with carrier status in females potentially harboring a severe Norrie disease gene mutation.

    Science.gov (United States)

    Khan, Arif O; Aldahmesh, Mohammed A; Meyer, Brian

    2008-04-01

    To correlate ophthalmic findings with carrier status for a severe Norrie disease (ND) gene mutation (C95F). Prospective interventional case series. Six potential carriers and 1 obligate carrier from a family harboring the mutation. An ophthalmologist blind to the pedigree performed a full ophthalmic examination for the 7 asymptomatic family members. A peripheral blood sample was collected from each for ND gene sequencing. Ophthalmic examination findings (with attention to the presence or absence of retinal findings) and results of ND gene sequencing. Three carriers were identified by molecular genetics, and all 3 of them had peripheral retinal abnormality. However, 3 of the 4 genetically identified noncarriers also exhibited peripheral retinal abnormality. Two of these noncarriers with retinal findings were the offspring of a confirmed noncarrier. The genetically identified noncarrier with a normal peripheral retinal examination was the daughter of an obligate carrier. The presence of peripheral retinal changes was not useful for carrier prediction in a family harboring ND. There are likely additional loci responsible for phenotypic expression.

  17. Refinement procedure for the image alignment in high-resolution electron tomography

    International Nuclear Information System (INIS)

    Houben, L.; Bar Sadan, M.

    2011-01-01

    High-resolution electron tomography from a tilt series of transmission electron microscopy images requires an accurate image alignment procedure in order to maximise the resolution of the tomogram. This is the case in particular for ultra-high resolution where even very small misalignments between individual images can dramatically reduce the fidelity of the resultant reconstruction. A tomographic-reconstruction based and marker-free method is proposed, which uses an iterative optimisation of the tomogram resolution. The method utilises a search algorithm that maximises the contrast in tomogram sub-volumes. Unlike conventional cross-correlation analysis it provides the required correlation over a large tilt angle separation and guarantees a consistent alignment of images for the full range of object tilt angles. An assessment based on experimental reconstructions shows that the marker-free procedure is competitive to the reference of marker-based procedures at lower resolution and yields sub-pixel accuracy even for simulated high-resolution data. -- Highlights: → Alignment procedure for electron tomography based on iterative tomogram contrast optimisation. → Marker-free, independent of object, little user interaction. → Accuracy competitive with fiducial marker methods and suited for high-resolution tomography.

  18. Efficacy and safety of fixed-combination bimatoprost/timolol ophthalmic solution

    OpenAIRE

    Moon, Suk Bae; Han, Sang Beom

    2017-01-01

    Suk Bae Moon,1 Sang Beom Han21Department of Surgery, Kangwon National University Hospital, Kangwon National University Graduate School of Medicine, Chuncheon, Korea, 2Department of Ophthalmology, Kangwon National University Hospital, Kangwon National University Graduate School of Medicine, Chuncheon, KoreaWe read, with interest, the article by Sun et al1 entitled “Patient satisfaction with fixed-combination bimatoprost/timolol ophthalmic solution: a survey study in patients with gla...

  19. Working in the magnetic field of ultrahigh field MRI

    International Nuclear Information System (INIS)

    Leitgeb, N.; Gombotz, H.

    2013-01-01

    Development of magnetic resonance imaging (MRI) device technology continues to increase the static magnetic flux densities applied and consequently leads to considerably increased occupational exposure. This has already made it necessary to review limits of occupational exposure and to postpone European legal regulations for occupational exposure to electromagnetic fields. This raises the question whether and if so which adverse health effects and health risks might be associated with occupational exposure to MRI ultra-high static magnetic fields. Based on a survey on interaction mechanisms recommendations and safety rules are presented to help minimize adverse health effects of emerging ultra-high field MRI. (orig.) [de

  20. Brain-heart interactions: challenges and opportunities with functional magnetic resonance imaging at ultra-high field.

    Science.gov (United States)

    Chang, Catie; Raven, Erika P; Duyn, Jeff H

    2016-05-13

    Magnetic resonance imaging (MRI) at ultra-high field (UHF) strengths (7 T and above) offers unique opportunities for studying the human brain with increased spatial resolution, contrast and sensitivity. However, its reliability can be compromised by factors such as head motion, image distortion and non-neural fluctuations of the functional MRI signal. The objective of this review is to provide a critical discussion of the advantages and trade-offs associated with UHF imaging, focusing on the application to studying brain-heart interactions. We describe how UHF MRI may provide contrast and resolution benefits for measuring neural activity of regions involved in the control and mediation of autonomic processes, and in delineating such regions based on anatomical MRI contrast. Limitations arising from confounding signals are discussed, including challenges with distinguishing non-neural physiological effects from the neural signals of interest that reflect cardiorespiratory function. We also consider how recently developed data analysis techniques may be applied to high-field imaging data to uncover novel information about brain-heart interactions. © 2016 The Author(s).

  1. Ophthalmic acid accumulation in an Escherichia coli mutant lacking the conserved pyridoxal 5'-phosphate-binding protein YggS.

    Science.gov (United States)

    Ito, Tomokazu; Yamauchi, Ayako; Hemmi, Hisashi; Yoshimura, Tohru

    2016-12-01

    Escherichia coli YggS is a highly conserved pyridoxal 5'-phosphate (PLP)-binding protein whose biochemical function is currently unknown. A previous study with a yggS-deficient E. coli strain (ΔyggS) demonstrated that YggS controls l-Ile- and l-Val-metabolism by modulating 2-ketobutyrate (2-KB), l-2-aminobutyrate (l-2-AB), and/or coenzyme A (CoA) availability in a PLP-dependent fashion. In this study, we found that ΔyggS accumulates an unknown metabolite as judged by amino acid analyses. LC/MS and MS/MS analyses of the compound with propyl chloroformate derivatization, and co-chromatography analysis identified this compound as γ-l-glutamyl-l-2-aminobutyryl-glycine (ophthalmic acid), a glutathione (GSH) analogue in which the l-Cys moiety is replaced by l-2-AB. We also determine the metabolic consequence of the yggS mutation. Absence of YggS initially increases l-2-AB availability, and then causes ophthalmic acid accumulation and CoA limitation in the cell. The expression of a γ-glutamylcysteine synthetase and a glutathione synthetase in a ΔyggS background causes high-level accumulation of ophthalmic acid in the cells (∼1.2 nmol/mg cells) in a minimal synthetic medium. This opens the possibility of a first fermentative production of ophthalmic acid. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  2. 76 FR 81806 - Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution

    Science.gov (United States)

    2011-12-29

    .... FDA-2011-N-0003] Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution... solution of ivermectin. DATES: This rule is effective December 29, 2011. FOR FURTHER INFORMATION CONTACT... ANADA 200-318 for [[Page 81807

  3. The ocular distribution of 14C-labeled bromfenac ophthalmic solution 0.07% in a rabbit model

    Directory of Open Access Journals (Sweden)

    Baklayan GA

    2014-09-01

    Full Text Available George A Baklayan, Mauricio Muñoz Bausch + Lomb, Irvine, CA, USA Purpose: To evaluate the ocular distribution of an advanced formulation of bromfenac ophthalmic solution. Two studies were conducted in rabbits: 1 a 12-hour parallel-group study comparing the ocular distribution of 14C-bromfenac ophthalmic solution 0.07%, pH 7.8 with that of 14C-bromfenac ophthalmic solution 0.09%, pH 8.3, and 2 a 24-hour study evaluating the ocular distribution of 14C-bromfenac ophthalmic solution 0.07%, pH 7.8.Methods: In the 12-hour study, rabbits were randomized to receive 50 µL of 14C-bromfenac 0.07%, pH 7.8 or 50 µL 14C-bromfenac 0.09%, pH 8.3 in one eye, whereas, in the 24-hour, study both eyes received 50 µL of 14C-bromfenac 0.07%, pH 7.8. Ocular tissues were collected at 1, 2, 4, 8, 12 (both studies and 24 hours (second study only following drug instillation, and tissue radioactivity was determined using liquid scintillation chromatography. Results: Measureable levels of bromfenac were observed in all ocular tissues, with the exception of vitreous humor, regardless of formulation. In the 12-hour study, high concentrations of 14C-bromfenac were found in the sclera, followed by the iris/ciliary body, aqueous humor, choroid, retina, and lens. There was no significant difference between the bromfenac 0.07%, pH 7.8 and bromfenac 0.09%, pH 8.3 formulations in any 14C-bromfenac tissue levels at any time point, with the exception of in sclera at 2 hours post-instillation (0.451 µg eq/g versus 0.302 µg eq/g, respectively, P<0.001. There was also no significant difference in the total amount of 14C-bromfenac in the tissues evaluated following instillation of the two formulations. In the 24-hour study evaluating bromfenac 0.07%, pH 7.8 only, high concentrations of 14C-bromfenac were found 1 hour post-instillation in the cornea (2.402 µg eq/g and conjunctiva (1.049 µg eq/g, two tissues not evaluated in the 12-hour study. The rank order of 14C

  4. An ophthalmic solution of a peroxisome proliferator-activated receptor gamma agonist prevents corneal inflammation in a rat alkali burn model.

    Science.gov (United States)

    Uchiyama, Masaaki; Shimizu, Akira; Masuda, Yukinari; Nagasaka, Shinya; Fukuda, Yuh; Takahashi, Hiroshi

    2013-01-01

    We clarified the effects of an ophthalmic solution of a peroxisome proliferator-activated receptor gamma (PPARγ) agonist on corneal inflammation and wound healing after alkali burn injury in rats. After alkali exposure, either an ophthalmic solution with 0.1% pioglitazone hydrochloride (the PPARγ group) or vehicle (the vehicle group) was topically applied to the cornea until day 14. Histological, immunohistochemical, and real-time reverse transcription polymerase chain reaction analysis were performed. After alkali injury, PPARγ expression increased, with the infiltration of many inflammatory cells. The infiltration of neutrophils and macrophages started from the corneal limbus within 6 h, and developed in the corneal center by day 7, with associated neovascularization. The accumulation of α-smooth muscle actin-positive myofibroblasts and the deposition of type III collagen were noted on day 14. The histological changes were suppressed significantly by treatment with the ophthalmic solution of the PPARγ agonist. In addition, the number of infiltrating M2 macrophages in the cornea was increased by PPARγ agonist treatment. In real-time reverse transcription polymerase chain reaction analysis, the messenger ribonucleic acid expression levels of interleukin-1β (IL-1β), IL-6, IL-8, monocyte chemoattractant protein-1, tumor necrosis factor-α, transforming growth factor beta 1, and vascular endothelial growth factor-A were decreased in the PPARγ group compared to the vehicle group in the early periods of corneal inflammation. The ophthalmic solution of the PPARγ agonist inhibited inflammation, decreased the fibrotic reaction, and prevented neovascularization in the cornea from the early phase after alkali burn injury. The ophthalmic solution of the PPARγ agonist may provide a new treatment strategy with useful clinical applications for corneal inflammation and wound healing.

  5. Protective Effect of Tea Polyphenol Ophthalmic Gel on Lens Epithelial Cells in Rabbits with Silicone Oil Tamponade after Vitrectomy

    Directory of Open Access Journals (Sweden)

    Xianzhen Ma

    2014-01-01

    Full Text Available Purpose. The aim of this study was to investigate the effect of tea polyphenols (TP ophthalmic gel on lens epithelial cells (LECs in rabbits with silicone oil tamponade after vitrectomy. Methods. In this study, unilateral vitrectomy with silicone oil tamponade was performed using 2-month-old New Zealand white rabbits (n = 72; meanwhile, age-matched nonoperated rabbits (n = 18 were used as controls. The TP ophthalmic gel was administered topically in the surgical eyes till they were sacrificed. On days 45 and 90 after operation, the levels of reactive oxygen species (ROS, mitochondrial membrane potential (ΔΨm, and apoptosis of LECs were analyzed, respectively. Meanwhile, caspase-3 mRNA and protein levels were also determined. Results. The results indicate that the levels of ROS and apoptosis were elevated for LECs in rabbits after operation, whereas ΔΨm was decreased. Caspase-3 was apparently increased at both mRNA and protein levels. Treatment of TP ophthalmic gel could reduce the generation of ROS, maintain ΔΨm, inhibit the overexpression of caspase-3, and thus decrease the apoptosis of LECs of rabbits after operation. Conclusions. TP ophthalmic gel can efficiently inhibit caspase-3 overexpression, reduce the apoptosis of LECs, and prevent LECs from damage. Our result provides a new approach to prevent the development of complicated cataract after vitrectomy.

  6. Ultra-high density aligned Carbon-nanotube with controled nano-morphology for supercapacitors

    Science.gov (United States)

    Ghaffari, Mehdi; Zhao, Ran; Liu, Yang; Zhou, Yue; Cheng, Jiping; Guzman de Villoria, Roberto; Wardle, B. L.; Zhang, Q. M.

    2012-02-01

    Recent advances in fabricating controlled-morphology vertically aligned carbon nanotubes (VA-CNTs) with ultrahigh volume fractioncreate unique opportunities for developing unconventional supercapacitors with ultra-high energy density, power density, and long charge/discharge cycle life.Continuous paths through inter-VA-CNT channels allow fast ion transport, and high electrical conduction of the aligned CNTs in the composite electrodes lead to fast discharge speed. We investigate the charge-discharge characteristics of VA-CNTs with >20 vol% of CNT and ionic liquids as electrolytes. By employing both the electric and electromechanical spectroscopes, as well as nanostructured materials characterization, the ion transport and storage behaviors in porous electrodes are studied. The results suggest pathways for optimizing the electrode morphology in supercapacitorsusing ultra-high volume fraction VA-CNTs to further enhance performance.

  7. Numerical Modeling of Ophthalmic Response to Space

    Science.gov (United States)

    Nelson, E. S.; Myers, J. G.; Mulugeta, L.; Vera, J.; Raykin, J.; Feola, A.; Gleason, R.; Samuels, B.; Ethier, C. R.

    2015-01-01

    To investigate ophthalmic changes in spaceflight, we would like to predict the impact of blood dysregulation and elevated intracranial pressure (ICP) on Intraocular Pressure (IOP). Unlike other physiological systems, there are very few lumped parameter models of the eye. The eye model described here is novel in its inclusion of the human choroid and retrobulbar subarachnoid space (rSAS), which are key elements in investigating the impact of increased ICP and ocular blood volume. Some ingenuity was required in modeling the blood and rSAS compartments due to the lack of quantitative data on essential hydrodynamic quantities, such as net choroidal volume and blood flowrate, inlet and exit pressures, and material properties, such as compliances between compartments.

  8. Progress, Performance, and Prospects of Ultra-High Resolution Microcalorimeter Spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Andrew Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bennett, D. A. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Croce, Mark Philip [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rabin, Michael W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ullom, J. N. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Univ. of Colorado, Boulder, CO (United States)

    2017-01-23

    In 2005 the LANL/NIST team used a single high-resolution microcalorimeter detector to measure the gamma-ray spectrum of a plutonium sample. After more than a decade of research and development on this topic, both the technology and our general understanding of its capabilities have advanced greatly, such that a progress review is now timely. We examine the scenario of a large-scale reprocessing plant and conclude that current non-destructive analysis (NDA) methods are inadequate to safeguard such a facility to the desired levels, leading to undesirable dependence on massspectrometry (MS) destructive analysis (DA). The development of microcalorimeter detectors is intended to close the performance gap between NDA and DA methods to address the needs of nuclear facilities.

  9. Regulation of vascular tone in rabbit ophthalmic artery: cross talk of endogenous and exogenous gas mediators.

    Science.gov (United States)

    Salomone, Salvatore; Foresti, Roberta; Villari, Ambra; Giurdanella, Giovanni; Drago, Filippo; Bucolo, Claudio

    2014-12-15

    Nitric oxide (NO), carbon monoxide (CO) and hydrogen sulphide (H2S) modulate vascular tone. In view of their therapeutic potential for ocular diseases, we examined the effect of exogenous CO and H2S on tone of isolated rabbit ophthalmic artery and their interaction with endogenous and exogenous NO. Ophthalmic artery segments mounted on a wire myograph were challenged with cumulative concentrations of phenylephrine (PE) in the presence or absence of NG-nitro-L-arginine (LNNA) to inhibit production of NO, the CO-releasing molecules CORMs or the H2S-donor GYY4137. The maximal vasoconstriction elicited by PE reached 20-30% of that induced by KCl but was dramatically increased by incubation with LNNA. GYY4137 significantly raised PE-mediated vasoconstriction, but it did not change the response to PE in the presence of LNNA or the relaxation to sodium nitroprusside (SNP). CORMs concentration-dependently inhibited PE-induced constriction, an effect that was synergistic with endogenous NO (reduced by LNNA), but insensitive to blockade of guanylyl cyclase by 1H-[1,2,4]oxadiazolo[4,3,-α]quinoxalin-1-one (ODQ). In vascular tissues cyclic GMP (cGMP) levels seemed reduced by GYY4137 (not significantly), but were not changed by CORM. These data indicate that CO is able per se to relax isolated ophthalmic artery and to synergize with NO, while H2S counteracts the effect of endogenous NO. CO does not stimulate cGMP production in our system, while H2S may reduce cGMP production stimulated by endogenous NO. These findings provide new insights into the complexities of gas interactions in the control of ophthalmic vascular tone, highlighting potential pharmacological targets for ocular diseases. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    Science.gov (United States)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.

  11. Bridging ultrahigh-Q devices and photonic circuits

    Science.gov (United States)

    Yang, Ki Youl; Oh, Dong Yoon; Lee, Seung Hoon; Yang, Qi-Fan; Yi, Xu; Shen, Boqiang; Wang, Heming; Vahala, Kerry

    2018-05-01

    Optical microresonators are essential to a broad range of technologies and scientific disciplines. However, many of their applications rely on discrete devices to attain challenging combinations of ultra-low-loss performance (ultrahigh Q) and resonator design requirements. This prevents access to scalable fabrication methods for photonic integration and lithographic feature control. Indeed, finding a microfabrication bridge that connects ultrahigh-Q device functions with photonic circuits is a priority of the microcavity field. Here, an integrated resonator having a record Q factor over 200 million is presented. Its ultra-low-loss and flexible cavity design brings performance to integrated systems that has been the exclusive domain of discrete silica and crystalline microcavity devices. Two distinctly different devices are demonstrated: soliton sources with electronic repetition rates and high-coherence/low-threshold Brillouin lasers. This multi-device capability and performance from a single integrated cavity platform represents a critical advance for future photonic circuits and systems.

  12. Stability-Indicating HPLC Method for Simultaneous Determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in Ophthalmic Solution.

    Science.gov (United States)

    AlAani, Hashem; Alnukkary, Yasmin

    2016-03-01

    A simple stability-indicating RP-HPLC assay method was developed and validated for quantitative determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in ophthalmic solution in the presence of 2-amino-1-(4-nitrophenyl)propane-1,3-diol, a degradation product of Chloramphenicol, and Dexamethasone, a degradation product of Dexamethasone Sodium Phosphate. Effective chromatographic separation was achieved using C18 column (250 mm, 4.6 mm i.d., 5 μm) with isocratic mobile phase consisting of acetonitrile - phosphate buffer (pH 4.0; 0.05 M) (30:70, v/v) at a flow rate of 1 mL/minute. The column temperature was maintained at 40°C and the detection wavelength was 230 nm. The proposed HPLC procedure was statistically validated according to the ICH guideline, and was proved to be stability-indicating by resolution of the APIs from their forced degradation products. The developed method is suitable for the routine analysis as well as stability studies.

  13. Imaging cells and sub-cellular structures with ultrahigh resolution full-field X-ray microscopy.

    Science.gov (United States)

    Chien, C C; Tseng, P Y; Chen, H H; Hua, T E; Chen, S T; Chen, Y Y; Leng, W H; Wang, C H; Hwu, Y; Yin, G C; Liang, K S; Chen, F R; Chu, Y S; Yeh, H I; Yang, Y C; Yang, C S; Zhang, G L; Je, J H; Margaritondo, G

    2013-01-01

    Our experimental results demonstrate that full-field hard-X-ray microscopy is finally able to investigate the internal structure of cells in tissues. This result was made possible by three main factors: the use of a coherent (synchrotron) source of X-rays, the exploitation of contrast mechanisms based on the real part of the refractive index and the magnification provided by high-resolution Fresnel zone-plate objectives. We specifically obtained high-quality microradiographs of human and mouse cells with 29 nm Rayleigh spatial resolution and verified that tomographic reconstruction could be implemented with a final resolution level suitable for subcellular features. We also demonstrated that a phase retrieval method based on a wave propagation algorithm could yield good subcellular images starting from a series of defocused microradiographs. The concluding discussion compares cellular and subcellular hard-X-ray microradiology with other techniques and evaluates its potential impact on biomedical research. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Ultrahigh Field NMR and MRI: Science at a Crossroads Workshop Report

    International Nuclear Information System (INIS)

    Polenova, Tatyana; Budinger, Thomas F.

    2016-01-01

    The workshop ''Ultrahigh Field NMR and MRI: Science at Crossroads'', initiated by the scientific community and supported by the National Science Foundation, the Department of Energy, and the National Institutes of Health, took place on November 12-13, 2015, in Bethesda, MD, on the NIH campus. The meeting was held to assess the science drivers, technological challenges, prospects for achieving field strengths for NMR and MRI nearly double their current value, and strategies on how to provide ultrahigh field NMR/MRI capabilities to a national user community.

  15. Ultra-high resolution spectroscopy of the He doubly excited states

    International Nuclear Information System (INIS)

    Bozek, J.D.; Schlachter, A.S.; Kaindl, G.; Schulz, K.

    1995-11-01

    Photoionization spectra of the doubly-excited states of He were measured using beamline 9.0.1 at the Advanced Light Source. The beamline utilizes a 4.5 m long 8 cm period undulator as its source together with a spherical grating monochromator to provide an extremely bright source of photons in the range of 20 - 300 eV. A resolving power (E/ΔE) of 64,000 was obtained from the 1 MeV FWEM (2p,3d) doubly excited state resonance of He at 64.12 eV. The high brightness of the source and the very high quality optical elements of the beamline were all essential for achieving such a high resolution. The beamline components and operation are described and spectra of the double excitation resonances of He presented

  16. Polystyrene negative resist for high-resolution electron beam lithography

    Directory of Open Access Journals (Sweden)

    Ma Siqi

    2011-01-01

    Full Text Available Abstract We studied the exposure behavior of low molecular weight polystyrene as a negative tone electron beam lithography (EBL resist, with the goal of finding the ultimate achievable resolution. It demonstrated fairly well-defined patterning of a 20-nm period line array and a 15-nm period dot array, which are the densest patterns ever achieved using organic EBL resists. Such dense patterns can be achieved both at 20 and 5 keV beam energies using different developers. In addition to its ultra-high resolution capability, polystyrene is a simple and low-cost resist with easy process control and practically unlimited shelf life. It is also considerably more resistant to dry etching than PMMA. With a low sensitivity, it would find applications where negative resist is desired and throughput is not a major concern.

  17. Low-Cost Ultra-High Spatial and Temporal Resolution Mapping of Intertidal Rock Platforms

    Science.gov (United States)

    Bryson, M.; Johnson-Roberson, M.; Murphy, R.

    2012-07-01

    Intertidal ecosystems have primarily been studied using field-based sampling; remote sensing offers the ability to collect data over large areas in a snapshot of time which could compliment field-based sampling methods by extrapolating them into the wider spatial and temporal context. Conventional remote sensing tools (such as satellite and aircraft imaging) provide data at relatively course, sub-meter resolutions or with limited temporal resolutions and relatively high costs for small-scale environmental science and ecology studies. In this paper, we describe a low-cost, kite-based imaging system and photogrammetric pipeline that was developed for constructing highresolution, 3D, photo-realistic terrain models of intertidal rocky shores. The processing pipeline uses automatic image feature detection and matching, structure-from-motion and photo-textured terrain surface reconstruction algorithms that require minimal human input and only a small number of ground control points and allow the use of cheap, consumer-grade digital cameras. The resulting maps combine colour and topographic information at sub-centimeter resolutions over an area of approximately 100m, thus enabling spatial properties of the intertidal environment to be determined across a hierarchy of spatial scales. Results of the system are presented for an intertidal rock platform at Cape Banks, Sydney, Australia. Potential uses of this technique include mapping of plant (micro- and macro-algae) and animal (e.g. gastropods) assemblages at multiple spatial and temporal scales.

  18. Dosimetry of Sr-90 ophthalmic applicators

    International Nuclear Information System (INIS)

    Reft, C.S.; Kuchnir, F.T.; Rosenberg, I.; Myrianthopoulos, L.C.

    1990-01-01

    Sr-90 ophthalmic applicators are commonly used for the treatment of superficial eye disorders. Although a variety of dosimetric devices such as film, thermoluminescent dosimeters (TLD's), ion chambers, and radiochromic foils have been used to measure the peak dose at the applicator surface, there is no internationally agreed upon calibration procedure. Recently, large discrepancies among calibrations of the same applicator at three institutions have been reported. Here we describe a technique to obtain the peak dose rate at the applicator surface using LiF TLD's. The technique can be used for the calibration of flat as well as curved surface applicators. Results for two flat and three concave applicators are presented. Our measurement of the surface dose rate for one of the flat applicators is compared with those obtained by four other institutions, each using different dosimetric devices

  19. Study on creep of fiber reinforced ultra-high strength concrete based on strength

    Science.gov (United States)

    Peng, Wenjun; Wang, Tao

    2018-04-01

    To complement the creep performance of ultra-high strength concrete, the long creep process of fiber reinforced concrete was studied in this paper. The long-term creep process and regularity of ultra-high strength concrete with 0.5% PVA fiber under the same axial compression were analyzed by using concrete strength (C80/C100/C120) as a variable. The results show that the creep coefficient of ultra-high strength concrete decreases with the increase of concrete strength. Compared with ACI209R (92), GL2000 models, it is found that the predicted value of ACI209R (92) are close to the experimental value, and the creep prediction model suitable for this experiment is proposed based on ACI209R (92).

  20. An ophthalmic solution of a peroxisome proliferator-activated receptor gamma agonist prevents corneal inflammation in a rat alkali burn model

    Science.gov (United States)

    Uchiyama, Masaaki; Masuda, Yukinari; Nagasaka, Shinya; Fukuda, Yuh; Takahashi, Hiroshi

    2013-01-01

    Purpose We clarified the effects of an ophthalmic solution of a peroxisome proliferator-activated receptor gamma (PPARγ) agonist on corneal inflammation and wound healing after alkali burn injury in rats. Methods After alkali exposure, either an ophthalmic solution with 0.1% pioglitazone hydrochloride (the PPARγ group) or vehicle (the vehicle group) was topically applied to the cornea until day 14. Histological, immunohistochemical, and real-time reverse transcription polymerase chain reaction analysis were performed. Results After alkali injury, PPARγ expression increased, with the infiltration of many inflammatory cells. The infiltration of neutrophils and macrophages started from the corneal limbus within 6 h, and developed in the corneal center by day 7, with associated neovascularization. The accumulation of α-smooth muscle actin-positive myofibroblasts and the deposition of type III collagen were noted on day 14. The histological changes were suppressed significantly by treatment with the ophthalmic solution of the PPARγ agonist. In addition, the number of infiltrating M2 macrophages in the cornea was increased by PPARγ agonist treatment. In real-time reverse transcription polymerase chain reaction analysis, the messenger ribonucleic acid expression levels of interleukin-1β (IL-1β), IL-6, IL-8, monocyte chemoattractant protein-1, tumor necrosis factor-α, transforming growth factor beta 1, and vascular endothelial growth factor-A were decreased in the PPARγ group compared to the vehicle group in the early periods of corneal inflammation. Conclusions The ophthalmic solution of the PPARγ agonist inhibited inflammation, decreased the fibrotic reaction, and prevented neovascularization in the cornea from the early phase after alkali burn injury. The ophthalmic solution of the PPARγ agonist may provide a new treatment strategy with useful clinical applications for corneal inflammation and wound healing. PMID:24194635

  1. Time Course of Prostaglandin Analog-related Conjunctival Hyperemia and the Effect of a Nonsteroidal Anti-inflammatory Ophthalmic Solution.

    Science.gov (United States)

    Sakata, Rei; Sakisaka, Toshihiro; Matsuo, Hiroshi; Miyata, Kazunori; Aihara, Makoto

    2016-03-01

    It is reported that nonsteroidal anti-inflammatory drug (NSAID) ophthalmic solution affected the therapeutic efficacy of prostaglandin (PG) analog by inhibiting endogenous PG production. However, whether NSAID ophthalmic solution interferes with its conjunctival hyperemia is unknown. We investigated the effect of NSAID ophthalmic solution on its hyperemia. This was a prospective, randomized, double-blind, placebo-controlled 1-month trial. Benzalkonium chloride-free travoprost 0.004% was used as a PG analog and administered once daily (08:00) in both eyes. Bromfenac sodium hydrate was assigned randomly to 1 eye twice daily (08:00 and 20:00) (the NSAID side), whereas flavin adenine dinucleotide sodium was applied to the fellow eye of each patient twice daily (08:00 and 20:00) (the control side). Conjunctival photographs of both eyes were taken 3 times (08:00, 14:00, 20:00) on days 1, 2, 7, and 28, and hyperemia was scored from 0 to 5 (H-score). We compared H-scores on the NSAID and control sides. Twenty-eight Japanese normal subjects completed the study. The H-score on the NSAID side was significantly lower than that on the control side on day 1 at 14:00 (P=0.016, paired t test) and day 2 at 14:00 (P=0.016). But there were no differences at 20:00 on each day and after that time. The use of NSAID ophthalmic solution had almost no impact on PG analog-related conjunctival hyperemia. This partly suggests that the action mechanism of endogenous PG after administrating PG analog might be no correlation with conjunctival hyperemia.

  2. Ultrahigh-resolution ultrasound characterization of access site trauma and intimal hyperplasia following use of a 7F sheathless guide versus 6F sheath/guide combination for transradial artery PCI: Results of the PRAGMATIC trial.

    Science.gov (United States)

    Batchelor, Wayne; Dahya, Vishal; McGee, Dan; Katopodis, John; Dixon, William; Campbell, James; Meredith, Ashley; Knap, Patty; Parkin, Mathew; Noel, Thomas

    2018-04-01

    There exist limited data on the relative degree of acute injury and late healing of the radial artery after transradial artery (TRA) percutaneous coronary intervention (PCI) with a 7F sheathless guide catheter compared with a 6F sheath/guide combination. We used ultrahigh-resolution (55 MHz) vascular ultrasound to compare intimal-medial thickening (IMT) and early and late radial artery (RA) injury resulting from a sheathless 7F guide catheter versus a 6F sheath/guide combination for TRA-PCI. Forty-one consecutive consenting patients undergoing elective nonemergent TRA-PCI at a single institution from June 2016 to December 2016 were included. Patients were randomized (stratified by sex) to undergo TRA-PCI using a 7F sheathless guide catheter versus a 6F sheath/6F guide combination. Ultrahigh-resolution vascular ultrasound (55MHz) of the RA access site was performed at 24hours and 90days post-TRA-PCI. The primary outcome of the study was a noninferiority comparison of radial artery IMT thickness at 90days. PCI success rates, fluoroscopy times, number of guides used, and crossover rates to a femoral approach were also compared. Baseline characteristics were similar between groups. Radial arterial IMT (mm) was similar between the 7F sheathless and 6F sheath/guide groups at 24hours (0.27 vs 0.29, respectively; P=.43) and at 90days (0.35 vs 0.34, respectively; P=.96). The P value for the noninferiority testing of a 0.07-mm limit was .002. Limited access site intimal tears were relatively common in both groups at 24hours (4 vs 5, P=.53) but often healed by 90days. Radial artery occlusion was infrequent at 90days (2 vs 1, P=.10), and no frank dissections were noted. PCI success rates (100% vs 95%, P=.59), fluoroscopy times (16 vs 12minutes, P=.17), number of guides used (1.1 vs 1.2, P=.48), and femoral crossover rates (0% vs 0%) were similar between the 2 respective groups. A 7F sheathless approach to TRA-PCI results in no more IMT and early or late RA trauma than a

  3. Seismic evidence for multiple-stage exhumation of high/ultrahigh pressure metamorphic rocks in the eastern Dabie orogenic belt

    Science.gov (United States)

    Luo, Yinhe; Zhao, Kaifeng; Tang, Chi-Chia; Xu, Yixian

    2018-05-01

    The Dabie-Sulu orogenic belt in China contains one of the largest exposures of high and ultrahigh pressure (HP and UHP) metamorphic rocks in the world. The origin of HP/UHP metamorphic rocks and their exhumation to the surface in this belt have attracted great interest in the geologic community because the study of exhumation history of HP/UHP rocks helps to understand the process of continental-continental collision and the tectonic evolution of post-collision. However, the exhumation mechanism of the HP-UHP rocks to the surface is still contentious. In this study, by deploying 28 broadband seismic stations in the eastern Dabie orogenic belt and combining seismic data from 40 stations of the China National Seismic Network (CNSN), we image the high-resolution crustal isotropic shear velocity and radial anisotropy structure using ambient noise tomography. Our high-resolution 3D models provide new information about the exhumation mechanism of HP/UHP rocks and the origin of two dome structures.

  4. Ultrahigh-energy cosmic rays: facts, myths and legends

    International Nuclear Information System (INIS)

    Anchordoqui, L.A.

    2011-01-01

    This is a written version of a series of lectures aimed at graduate students in astrophysics and theoretical/experimental particle physics. In the first part, we explain the important progress made in recent years towards understanding the experimental data on cosmic rays with energies > or approx. 10 8 GeV. We begin with a brief survey of the available data, including a description of the energy spectrum, mass composition and arrival directions. At this point we also give a short overview of experimental techniques. After that, we introduce the fundamentals of acceleration and propagation in order to discuss the conjectured nearby cosmic-ray sources, and emphasize some of the prospects for a new (multiparticle) astronomy. Next, we survey the state of the art regarding the ultrahigh-energy cosmic neutrinos that should be produced in association with the observed cosmic rays. In the second part, we summarize the phenomenology of cosmic-ray air showers. We explain the hadronic interaction models used to extrapolate results from collider data to ultrahigh energies, and describe the prospects for insights into forward physics at the Large Hadron Collider. We also explain the main electromagnetic processes that govern the longitudinal shower evolution. Armed with these two principal shower ingredients and motivation from the underlying physics, we describe the different methods proposed to distinguish primary species. In the last part, we outline how ultrahigh-energy cosmic-ray interactions can be used to probe new physics beyond the electroweak scale. (author)

  5. A self-calibrating optomechanical force sensor with femtonewton resolution

    International Nuclear Information System (INIS)

    Melcher, John; Stirling, Julian; Pratt, Jon R.; Shaw, Gordon A.; Cervantes, Felipe Guzmán

    2014-01-01

    We report the development of an ultrasensitive optomechanical sensor designed to improve the accuracy and precision of force measurements with atomic force microscopy. The sensors reach quality factors of 4.3 × 10 6 and force resolution on the femtonewton scale at room temperature. Self-calibration of the sensor is accomplished using radiation pressure to create a reference force. Self-calibration enables in situ calibration of the sensor in extreme environments, such as cryogenic ultra-high vacuum. The senor technology presents a viable route to force measurements at the atomic scale with uncertainties below the percent level

  6. A self-calibrating optomechanical force sensor with femtonewton resolution

    Energy Technology Data Exchange (ETDEWEB)

    Melcher, John, E-mail: john.melcher@nist.gov; Stirling, Julian; Pratt, Jon R.; Shaw, Gordon A. [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Cervantes, Felipe Guzmán [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Joint Quantum Institute, University of Maryland, College Park, Maryland 20742 (United States)

    2014-12-08

    We report the development of an ultrasensitive optomechanical sensor designed to improve the accuracy and precision of force measurements with atomic force microscopy. The sensors reach quality factors of 4.3 × 10{sup 6} and force resolution on the femtonewton scale at room temperature. Self-calibration of the sensor is accomplished using radiation pressure to create a reference force. Self-calibration enables in situ calibration of the sensor in extreme environments, such as cryogenic ultra-high vacuum. The senor technology presents a viable route to force measurements at the atomic scale with uncertainties below the percent level.

  7. AMANDA Observations Constrain the Ultrahigh Energy Neutrino Flux

    Energy Technology Data Exchange (ETDEWEB)

    Halzen, Francis; /Wisconsin U., Madison; Hooper, Dan; /Fermilab

    2006-05-01

    A number of experimental techniques are currently being deployed in an effort to make the first detection of ultra-high energy cosmic neutrinos. To accomplish this goal, techniques using radio and acoustic detectors are being developed, which are optimally designed for studying neutrinos with energies in the PeV-EeV range and above. Data from the AMANDA experiment, in contrast, has been used to place limits on the cosmic neutrino flux at less extreme energies (up to {approx}10 PeV). In this letter, we show that by adopting a different analysis strategy, optimized for much higher energy neutrinos, the same AMANDA data can be used to place a limit competitive with radio techniques at EeV energies. We also discuss the sensitivity of the IceCube experiment, in various stages of deployment, to ultra-high energy neutrinos.

  8. Analysis of carbon and nitrogen co-metabolism in yeast by ultrahigh-resolution mass spectrometry applying 13C- and 15N-labeled substrates simultaneously

    International Nuclear Information System (INIS)

    Blank, Lars M.; Desphande, Rahul R.; Schmid, Andreas; Hayen, Heiko

    2012-01-01

    Alternative metabolic pathways inside a cell can be deduced using stable isotopically labeled substrates. One prerequisite is accurate measurement of the labeling pattern of targeted metabolites. Experiments are generally limited to the use of single-element isotopes, mainly 13 C. Here, we demonstrate the application of direct infusion nanospray, ultrahigh-resolution Fourier transform ion cyclotron resonance-mass spectrometry (FTICR-MS) for metabolic studies using differently labeled elemental isotopes simultaneously - i.e., 13 C and 15 N - in amino acids of a total protein hydrolysate. The optimized strategy for the analysis of metabolism by a hybrid linear ion trap-FTICR-MS comprises the collection of multiple adjacent selected ion monitoring scans. By limiting both the width of the mass range and the number of ions entering the ICR cell with automated gain control, sensitive measurements of isotopologue distribution were possible without compromising mass accuracy and isotope intensity mapping. The required mass-resolving power of more than 60,000 is only achievable on a routine basis by FTICR and Orbitrap mass spectrometers. Evaluation of the method was carried out by comparison of the experimental data to the natural isotope abundances of selected amino acids and by comparison to GC/MS results obtained from a labeling experiment with 13 C-labeled glucose. The developed method was used to shed light on the complexity of the yeast Saccharomyces cerevisiae carbon-nitrogen co-metabolism by administering both 13 C-labeled glucose and 15 N-labeled alanine. The results indicate that not only glutamate but also alanine acts as an amino donor during alanine and valine synthesis. Metabolic studies using FTICR-MS can exploit new possibilities by the use of multiple-labeled elemental isotopes. (orig.)

  9. An historical ophthalmic study of Jane Austen.

    Science.gov (United States)

    Wilson, Graham A

    2012-11-01

    Today, no other classic novelist has the popularity or power of Jane Austen, and in 2013 the world will celebrate 200 years of her comic masterpiece Pride and Prejudice. Her millions of fans have an abiding fascination with all aspects of her life, including her health and the cause of her death. This historical ophthalmic study of Jane Austen, based on very incomplete medical bibliographic data, finds that she had a mild ocular surface disorder from age 23. This disorder did not significantly impact on her visual performance for writing. There are many references to eyes in her novels, but Jane's eyes and those of her characters cannot contribute further to the debate around the cause of her death at age 41.

  10. Status of Ultra-High Energy Cosmic Rays

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    I will review the recent results on Ultra-High energy cosmic rays obtained by the Auger and Telescope Array Observatories, and discuss some of the Astrophysical scenarios that could account for them, a connection with LHC results  as well as the possible connections to neutrino and gamma ray observations.

  11. Ultrahigh Field NMR and MRI: Science at a Crossroads Workshop Report

    Energy Technology Data Exchange (ETDEWEB)

    Polenova, Tatyana [Univ. of Delaware, Newark, DE (United States); Budinger, Thomas F. [Univ. of California, Berkeley, CA (United States)

    2016-01-04

    The workshop “Ultrahigh Field NMR and MRI: Science at Crossroads”, initiated by the scientific community and supported by the National Science Foundation, the Department of Energy, and the National Institutes of Health, took place on November 12-13, 2015, in Bethesda, MD, on the NIH campus. The meeting was held to assess the science drivers, technological challenges, prospects for achieving field strengths for NMR and MRI nearly double their current value, and strategies on how to provide ultrahigh field NMR/MRI capabilities to a national user community.

  12. Coherent Pound-Drever-Hall technique for high resolution fiber optic strain sensor at very low light power

    Science.gov (United States)

    Wu, Mengxin; Liu, Qingwen; Chen, Jiageng; He, Zuyuan

    2017-04-01

    Pound-Drever-Hall (PDH) technique has been widely adopted for ultrahigh resolution fiber-optic sensors, but its performance degenerates seriously as the light power drops. To solve this problem, we developed a coherent PDH technique for weak optical signal detection, with which the signal-to-noise ratio (SNR) of demodulated PDH signal is dramatically improved. In the demonstrational experiments, a high resolution fiber-optic sensor using the proposed technique is realized, and n"-order strain resolution at a low light power down to -43 dBm is achieved, which is about 15 dB lower compared with classical PDH technique. The proposed coherent PDH technique has great potentials in longer distance and larger scale sensor networks.

  13. Cryogenic Microcalorimeter System for Ultra-High Resolution Alpha-Particle Spectrometry

    Science.gov (United States)

    Croce, M. P.; Bacrania, M. K.; Hoover, A. S.; Rabin, M. W.; Hoteling, N. J.; LaMont, S. P.; Plionis, A. A.; Dry, D. E.; Ullom, J. N.; Bennett, D. A.; Horansky, R. D.; Kotsubo, V.; Cantor, R.

    2009-12-01

    Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with ˜15-μK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis. This paper will discuss design and operation of our microcalorimeter alpha-particle spectrometer, and will show recent results.

  14. Cryogenic microcalorimeter system for ultra-high resolution alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Rabin, Michael W.; Hoover, Andrew S.; Bacrania, Minesh K.; Croce, Mark P.; Hoteling, N.J.; Lamont, S.P.; Plionis, A.A.; Dry, D.E.; Ullom, J.N.; Bennett, D.A.; Horansky, R.; Kotsubo, V.; Cantor, R.

    2009-01-01

    Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with ∼15 uK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis, This paper will discuss design and operation of our microcalorimeter alpha spectrometer, and will show recent results.

  15. The effect of ketamine on the separation anxiety and emergence agitation in children undergoing brief ophthalmic surgery under desflurane general anesthesia

    OpenAIRE

    Jeong, Won Ju; Kim, Woon Young; Moon, Man Gook; Min, Doo Jae; Lee, Yoon Sook; Kim, Jae Hwan; Park, Young Cheol

    2012-01-01

    Background Emergence agitation (EA) frequently occurs after desflurane anesthesia in children. Ketamine, because of its sedative and analgesic properties, might be useful for the management of separation anxiety and EA. We investigated the preventive effect of ketamine on separation anxiety and EA after desflurane anesthesia in children for brief ophthalmic surgery. Methods Sixty children, ranging in age from 2-8 years old, undergoing brief ophthalmic surgery were randomly allocated to one of...

  16. CHECKPOINT INHIBITOR IMMUNE THERAPY: Systemic Indications and Ophthalmic Side Effects.

    Science.gov (United States)

    Dalvin, Lauren A; Shields, Carol L; Orloff, Marlana; Sato, Takami; Shields, Jerry A

    2018-06-01

    To review immune checkpoint inhibitor indications and ophthalmic side effects. A literature review was performed using a PubMed search for publications between 1990 and 2017. Immune checkpoint inhibitors are designed to treat system malignancies by targeting one of three ligands, leading to T-cell activation for attack against malignant cells. These ligands (and targeted drug) include cytotoxic T-lymphocyte antigen-4 (CTLA-4, ipilimumab), programmed death protein 1 (PD-1, pembrolizumab, nivolumab), and programmed death ligand-1 (PD-L1, atezolizumab, avelumab, durvalumab). These medications upregulate the immune system and cause autoimmune-like side effects. Ophthalmic side effects most frequently manifest as uveitis (1%) and dry eye (1-24%). Other side effects include myasthenia gravis (n = 19 reports), inflammatory orbitopathy (n = 11), keratitis (n = 3), cranial nerve palsy (n = 3), optic neuropathy (n = 2), serous retinal detachment (n = 2), extraocular muscle myopathy (n = 1), atypical chorioretinal lesions (n = 1), immune retinopathy (n = 1), and neuroretinitis (n = 1). Most inflammatory side effects are managed with topical or periocular corticosteroids, but advanced cases require systemic corticosteroids and cessation of checkpoint inhibitor therapy. Checkpoint inhibitors enhance the immune system by releasing inhibition on T cells, with risk of autoimmune-like side effects. Ophthalmologists should include immune-related adverse events in their differential when examining cancer patients with new ocular symptoms.

  17. Laser beam welding of new ultra-high strength and supra-ductile steels

    OpenAIRE

    Dahmen, M.

    2015-01-01

    Ultra-high strength and supra-ductile are entering fields of new applications. Those materials are excellent candidates for modern light-weight construction and functional integration. As ultra-high strength steels the stainless martensitic grade 1.4034 and the bainitic steel UNS 53835 are investigated. For the supra-ductile steels stand two high austenitic steels with 18 and 28 % manganese. As there are no processing windows an approach from the metallurgical base on is required. Adjusting t...

  18. Geometric scaling in ultrahigh energy neutrinos and nonlinear perturbative QCD

    International Nuclear Information System (INIS)

    Machado, Magno V.T.

    2011-01-01

    The ultrahigh energy neutrino cross section is a crucial ingredient in the calculation of the event rate in high energy neutrino telescopes. Currently there are several approaches which predict different behaviors for its magnitude for ultrahigh energies. In this contribution is presented a summary of current predictions based on the non-linear QCD evolution equations, the so-called perturbative saturation physics. In particular, predictions are shown based on the parton saturation approaches and the consequences of geometric scaling property at high energies are discussed. The scaling property allows an analytical computation of the neutrino scattering on nucleon/nucleus at high energies, providing a theoretical parameterization. (author)

  19. Laser beam welding of new ultra-high strength and supra-ductile steels

    Science.gov (United States)

    Dahmen, Martin

    2015-03-01

    Ultra-high strength and supra-ductile are entering fields of new applications. Those materials are excellent candidates for modern light-weight construction and functional integration. As ultra-high strength steels the stainless martensitic grade 1.4034 and the bainitic steel UNS 53835 are investigated. For the supra-ductile steels stand two high austenitic steels with 18 and 28 % manganese. As there are no processing windows an approach from the metallurgical base on is required. Adjusting the weld microstructure the Q+P and the QT steels require weld heat treatment. The HSD steel is weldable without. Due to their applications the ultra-high strength steels are welded in as-rolled and strengthened condition. Also the reaction of the weld on hot stamping is reflected for the martensitic grades. The supra-ductile steels are welded as solution annealed and work hardened by 50%. The results show the general suitability for laser beam welding.

  20. Efficacy and safety of retinol palmitate ophthalmic solution in the treatment of dry eye: a Japanese Phase II clinical trial.

    Science.gov (United States)

    Toshida, Hiroshi; Funaki, Toshinari; Ono, Koichi; Tabuchi, Nobuhito; Watanabe, Sota; Seki, Tamotsu; Otake, Hiroshi; Kato, Takuji; Ebihara, Nobuyuki; Murakami, Akira

    2017-01-01

    The purpose of this study was to investigate the efficacy and safety of the administration of retinol palmitate (VApal) ophthalmic solution (500 IU/mL) for the treatment of patients with dry eye. This study included 66 patients with dry eye. After a 2-week washout period, patients were randomized (1:1) into either a VApal ophthalmic solution or a placebo group, and a single drop of either solution was administered six times daily for 4 weeks. Efficacy measures were 12 subjective symptoms, rose bengal (RB) and fluorescein staining scores, tear film breakup time, and tear secretion. Safety measures included clinical blood and urine analyses and adverse event recordings. In comparisons of the two groups, the mean change in RB staining score from baseline was significantly lower in the VApal group at 2 and 4 weeks ( P ophthalmic solution (500 IU/mL) is safe and effective for the treatment of patients with dry eye.

  1. Soliton-based ultra-high speed optical communications

    Indian Academy of Sciences (India)

    All these facts are the outcome of research on optical solitons in fibers in spite of the fact that the commonly used RZ format is not always called a soliton format. The overview presented here attempts to incorporate the role of soliton-based communications research in present day ultra-high speed communications.

  2. Proton-proton elastic scattering at ultrahigh energies

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, M.; Shaukat, M.A.; Fazal-e-Aleem (University of the Punjab, Lahore (Pakistan). Dept. of Physics)

    1981-05-30

    The authors use a geometrical model of high-energy pp elastic scattering as proposed by Chou and Yong to analyse experimental data available at present and consider the predictions of the dipole pomeron model for pp elastic scattering at ultrahigh energies. Theoretical results for differential cross sections are compared with experimental data.

  3. Effectiveness of ophthalmic solution preservatives: a comparison of latanoprost with 0.02% benzalkonium chloride and travoprost with the sofZia preservative system

    OpenAIRE

    Ryan, Gerard; Fain, Joel M; Lovelace, Cherie; Gelotte, Karl M

    2011-01-01

    Abstract Background Although in vitro and in vivo laboratory studies have suggested that benzalkonium chloride (BAK) in topical ophthalmic solutions may be detrimental to corneal epithelial cells, multiple short- and long-term clinical studies have provided evidence supporting the safety of BAK. Despite the conflicting evidence, BAK is the most commonly used preservative in ophthalmic products largely due to its proven antimicrobial efficacy. This study was designed to characterize the antimi...

  4. Molecular characterization of water soluble organic nitrogen in marine rainwater by ultra-high resolution electrospray ionization mass spectrometry

    Directory of Open Access Journals (Sweden)

    K. E. Altieri

    2012-04-01

    Full Text Available Atmospheric water soluble organic nitrogen (WSON is a subset of the complex organic matter in aerosols and rainwater, which impacts cloud condensation processes and aerosol chemical and optical properties and may play a significant role in the biogeochemical cycle of N. However, its sources, composition, connections to inorganic N, and variability are largely unknown. Rainwater samples were collected on the island of Bermuda (32.27° N, 64.87° W, which experiences both anthropogenic and marine influenced air masses. Samples were analyzed by ultra-high resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry to chemically characterize the WSON. Elemental compositions of 2281 N containing compounds were determined over the mass range m/z+ 50 to 500. The five compound classes with the largest number of elemental formulas identified, in order from the highest number of formulas to the lowest, contained carbon, hydrogen, oxygen, and nitrogen (CHON+, CHON compounds that contained sulfur (CHONS+, CHON compounds that contained phosphorus (CHONP+, CHON compounds that contained both sulfur and phosphorus (CHONSP+, and compounds that contained only carbon, hydrogen, and nitrogen (CHN+. Compared to rainwater collected in the continental USA, average O:C ratios of all N containing compound classes were lower in the marine samples whereas double bond equivalent values were higher, suggesting a reduced role of secondary formation mechanisms. Despite their prevalence in continental rainwater, no organonitrates or nitrooxy-organosulfates were detected, but there was an increased presence of organic S and organic P containing compounds in the marine rainwater. Cluster analysis showed a clear chemical distinction between samples collected during the cold season (October to March which have anthropogenic air mass origins and samples collected during the warm season (April to September with remote

  5. Gasserian Ganglion and Retrobulbar Nerve Block in the Treatment of Ophthalmic Postherpetic Neuralgia: A Case Report.

    Science.gov (United States)

    Huang, Jie; Ni, Zhongge; Finch, Philip

    2017-09-01

    Varicella zoster virus reactivation can cause permanent histological changes in the central and peripheral nervous system. Neural inflammatory changes or damage to the dorsal root ganglia sensory nerve fibers during reactivation can lead to postherpetic neuralgia (PHN). For PHN of the first division of the fifth cranial nerve (ophthalmic division of the trigeminal ganglion), there is evidence of inflammatory change in the ganglion and adjacent ocular neural structures. First division trigeminal nerve PHN can prove to be difficult and sometimes even impossible to manage despite the use of a wide range of conservative measures, including anticonvulsant and antidepressant medication. Steroids have been shown to play an important role by suppressing neural inflammatory processes. We therefore chose the trigeminal ganglion as an interventional target for an 88-year-old woman with severe ophthalmic division PHN after she failed to respond to conservative treatment. Under fluoroscopic guidance, a trigeminal ganglion nerve block was performed with lidocaine combined with dexamethasone. A retrobulbar block with lidocaine and triamcinolone settled residual oculodynia. At 1-year follow-up, the patient remained pain free and did not require analgesic medication. To our knowledge, this is the first reported case of ophthalmic division PHN successfully treated with a combination of trigeminal ganglion and retrobulbar nerve block using a local anesthetic agent and steroid for central and peripheral neural inflammatory processes. © 2016 World Institute of Pain.

  6. 75 FR 26647 - Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution

    Science.gov (United States)

    2010-05-12

    .... FDA-2010-N-0002] Ophthalmic and Topical Dosage Form New Animal Drugs; Ivermectin Topical Solution... are treated with a topical solution of ivermectin. DATES: This rule is effective May 12, 2010. FOR... ANADA 200-340 for PRIVERMECTIN (ivermectin), a topical solution used on cattle to control infestations...

  7. Systemic absorption and adverse ocular and systemic effects after topical ophthalmic administration of 0.1% diclofenac to healthy cats.

    Science.gov (United States)

    Hsu, Kimberly K; Pinard, Chantale L; Johnson, Ron J; Allen, Dana G; KuKanich, Butch K; Nykamp, Stephanie G

    2015-03-01

    To quantify plasma concentrations and determine adverse ocular, renal, or hepatic effects associated with repeated topical ophthalmic application of 0.1% diclofenac to healthy cats. 8 healthy sexually intact male cats. A randomized, placebo-controlled crossover study was conducted. A topical formulation of 0.1% diclofenac was administered 4 times/d for 7 days to 4 cats, and artificial tear (control) solution was administered to the other 4 cats. After a 12-day washout period, cats received the other treatment. Ophthalmic examinations were performed daily. Plasma samples were obtained on days 1 and 7 for pharmacokinetic analysis. A CBC, serum biochemical analysis, urinalysis, determination of urine protein-to-creatinine ratio, and determination of glomerular filtration rate were performed before the start of the study and after each 7-day treatment period. Mild conjunctival hyperemia was the only adverse ocular effect detected. Maximal drug concentration and area under the curve were significantly higher on day 7 than on day 1. Diclofenac-treated cats had a significantly lower glomerular filtration rate than did control-treated cats after the second but not after the first treatment period, presumably associated with iatrogenic hypovolemia. Topical ophthalmic administration of 0.1% diclofenac was well tolerated in healthy cats, with only mild signs of ocular irritation. Detectable systemic concentrations of diclofenac were achieved with accumulation over 7 days. Systemic absorption of diclofenac may be associated with reduced glomerular filtration rate, particularly in volume-contracted animals. Topical ophthalmic 0.1% diclofenac should be used with caution in volume-contracted or systemically ill cats.

  8. Effectiveness and relevant factors of 2% rebamipide ophthalmic suspension treatment in dry eye.

    Science.gov (United States)

    Ueda, Kaori; Matsumiya, Wataru; Otsuka, Keiko; Maeda, Yoshifumi; Nagai, Takayuki; Nakamura, Makoto

    2015-06-06

    Rebamipide with mucin secretagogue activity was recently approved for the treatment of dry eye. The efficacy and safety in the treatment of rebamipide were shown in two pivotal clinical trials. It was the aim of this study to evaluate the effect of 2% rebamipide ophthalmic suspension in patients with dry eye and analyze relevant factors for favorable effects of rebamipide in clinical practice. This was a retrospective cohort study of 48 eyes from 24 patients with dry eye treated with 2% rebamipide ophthalmic suspension. Dry eye-related symptom score, tear film break-up time (TBUT), fluorescein ocular surface staining score (FOS) and the Schirmer test were used to collect the data from patients at baseline, and at 2, 4, 8, and 12 week visits. To determine the relevant factors, multiple regression analyses were then performed. Mean dry eye-related symptom score showed a significant improvement from the baseline (14.5 points) at 2, 4, 8 and 12 weeks (9.80, 7.04, 7.04 and 7.83 points, corrected P value treatment. For ocular symptoms, three parameters (foreign body sensation, dry eye sensation and ocular discomfort) showed significant improvements at all visits. The multiple regression analyses showed that the fluorescein conjunctiva staining score was significantly correlated with the changes of dry eye-related symptom score at 12 weeks (P value = 0.017) and dry eye-related symptom score was significantly correlated with independent variables for the changes of FOS at 12 weeks (P value = 0.0097). Two percent rebamipide ophthalmic suspension was an effective therapy for dry eye patients. Moreover the fluorescein conjunctiva staining score and dry eye-related symptom score might be good relevant factors for favorable effects of rebamipide.

  9. Mucoadhesive Cyclodextrin-Modified Thiolated Poly(aspartic acid as a Potential Ophthalmic Drug Delivery System

    Directory of Open Access Journals (Sweden)

    Mária Budai-Szűcs

    2018-02-01

    Full Text Available Thiolated poly(aspartic acid is known as a good mucoadhesive polymer in aqueous ophthalmic formulations. In this paper, cyclodextrin-modified thiolated poly(aspartic acid was synthesized for the incorporation of prednisolone, a lipophilic ophthalmic drug, in an aqueous in situ gellable mucoadhesive solution. This polymer combines the advantages of cyclodextrins and thiolated polymers. The formation of the cyclodextrin-drug complex in the gels was analyzed by X-ray powder diffraction. The ocular applicability of the polymer was characterized by means of physicochemical, rheological and drug diffusion tests. It was established that the chemical bonding of the cyclodextrin molecule did not affect the complexation of prednisolone, while the polymer solution preserved its in situ gellable and good mucoadhesive characteristics. The chemical immobilization of cyclodextrin modified the diffusion profile of prednisolone and prolonged drug release was observed. The combination of free and immobilized cyclodextrins provided the best release profile because the free complex can diffuse rapidly, while the bonded complex ensures a prolonged action.

  10. Scaling violations at ultra-high energies

    International Nuclear Information System (INIS)

    Tung, W.K.

    1979-01-01

    The paper discusses some of the features of high energy lepton-hadron scattering, including the observed (Bjorken) scaling behavior. The cross-sections where all hadron final states are summed over, are examined and the general formulas for the differential cross-section are examined. The subjects of scaling, breaking and phenomenological consequences are studied, and a list of what ultra-high energy neutrino physics can teach QCD is given

  11. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    International Nuclear Information System (INIS)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio

    2015-01-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  12. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    Energy Technology Data Exchange (ETDEWEB)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  13. A new processing scheme for ultra-high resolution direct infusion mass spectrometry data

    Science.gov (United States)

    Zielinski, Arthur T.; Kourtchev, Ivan; Bortolini, Claudio; Fuller, Stephen J.; Giorio, Chiara; Popoola, Olalekan A. M.; Bogialli, Sara; Tapparo, Andrea; Jones, Roderic L.; Kalberer, Markus

    2018-04-01

    High resolution, high accuracy mass spectrometry is widely used to characterise environmental or biological samples with highly complex composition enabling the identification of chemical composition of often unknown compounds. Despite instrumental advancements, the accurate molecular assignment of compounds acquired in high resolution mass spectra remains time consuming and requires automated algorithms, especially for samples covering a wide mass range and large numbers of compounds. A new processing scheme is introduced implementing filtering methods based on element assignment, instrumental error, and blank subtraction. Optional post-processing incorporates common ion selection across replicate measurements and shoulder ion removal. The scheme allows both positive and negative direct infusion electrospray ionisation (ESI) and atmospheric pressure photoionisation (APPI) acquisition with the same programs. An example application to atmospheric organic aerosol samples using an Orbitrap mass spectrometer is reported for both ionisation techniques resulting in final spectra with 0.8% and 8.4% of the peaks retained from the raw spectra for APPI positive and ESI negative acquisition, respectively.

  14. Testing and Modeling Ultra-High Temperature Ceramic (UHTC) Materials For Hypersonic Flight

    Science.gov (United States)

    2011-11-30

    Ridge, D. G. Fletcher, C. O. Asma , O. Chazot, and J. Thömel, “Oxidation of ZrB2-SiC Ultra-High Temperature Ceramic Composites in Dissociated Air...Fletcher, C. O. Asma , “Characterization of ZrB2-SiC Ceramics Tested by Plasma Stream Oxidation,” poster, 32 th International Conference...Fahrenholtz, W.G., Hilmas, G.E., Zhu, S.M., Ridge, J., Fletcher, D.G., Asma , C.O., and Thomel, J., "Oxidation of ZrB2-SiC Ultrahigh-Temperature

  15. Ultrahigh temperature deformation microstructures in felsic granulites of the Napier Complex, Antarctica

    DEFF Research Database (Denmark)

    Lund, Majbritt Deichgræber; Piazolo, Sandra; Harley, Simon L

    2006-01-01

    Detailed electron microscope and microstructural analysis of two ultrahigh temperature felsic granulites from Tonagh Island, Napier Complex, Antarctica show deformation microstructures produced at ∼1000 °C at 8-10 kbar. High temperature orthopyroxene (Al ∼7 wt.% and ∼11 wt.%), exhibits crystallog......Detailed electron microscope and microstructural analysis of two ultrahigh temperature felsic granulites from Tonagh Island, Napier Complex, Antarctica show deformation microstructures produced at ∼1000 °C at 8-10 kbar. High temperature orthopyroxene (Al ∼7 wt.% and ∼11 wt.%), exhibits...

  16. Location of the internal carotid artery and ophthalmic artery segments for non-invasive intracranial pressure measurement by multi-depth TCD.

    Science.gov (United States)

    Hamarat, Yasin; Deimantavicius, Mantas; Kalvaitis, Evaldas; Siaudvytyte, Lina; Januleviciene, Ingrida; Zakelis, Rolandas; Bartusis, Laimonas

    2017-12-01

    The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.

  17. Structure of the SH3 domain of human osteoclast-stimulating factor at atomic resolution

    International Nuclear Information System (INIS)

    Chen, Liqing; Wang, Yujun; Wells, David; Toh, Diana; Harold, Hunt; Zhou, Jing; DiGiammarino, Enrico; Meehan, Edward J.

    2006-01-01

    The crystal structure of the SH3 domain of human osteoclast-stimulating factor has been determined and refined to the ultrahigh resolution of 1.07 Å. The structure at atomic resolution provides an accurate framework for structure-based design of its inhibitors. Osteoclast-stimulating factor (OSF) is an intracellular signaling protein, produced by osteoclasts themselves, that enhances osteoclast formation and bone resorption. It is thought to act via an Src-related signaling pathway and contains SH3 and ankyrin-repeat domains which are involved in protein–protein interactions. As part of a structure-based anti-bone-loss drug-design program, the atomic resolution X-ray structure of the recombinant human OSF SH3 domain (hOSF-SH3) has been determined. The domain, residues 12–72, yielded crystals that diffracted to the ultrahigh resolution of 1.07 Å. The overall structure shows a characteristic SH3 fold consisting of two perpendicular β-sheets that form a β-barrel. Structure-based sequence alignment reveals that the putative proline-rich peptide-binding site of hOSF-SH3 consists of (i) residues that are highly conserved in the SH3-domain family, including residues Tyr21, Phe23, Trp49, Pro62, Asn64 and Tyr65, and (ii) residues that are less conserved and/or even specific to hOSF, including Thr22, Arg26, Thr27, Glu30, Asp46, Thr47, Asn48 and Leu60, which might be key to designing specific inhibitors for hOSF to fight osteoporosis and related bone-loss diseases. There are a total of 13 well defined water molecules forming hydrogen bonds with the above residues in and around the peptide-binding pocket. Some of those water molecules might be important for drug-design approaches. The hOSF-SH3 structure at atomic resolution provides an accurate framework for structure-based design of its inhibitors

  18. Stacking it up: Exploring the limits of ultra-high resolution atomic force microscopy

    NARCIS (Netherlands)

    van der Heijden, N.J.

    2017-01-01

    Atomic force microscopy (AFM) is a technique wherein an atomically sharp needle raster scans across a surface, detecting forces between it and the sample. In state-of-the-art AFM experiments the measured forces are typically on the order of pico-Newtons, and the lateral resolution is on the order of

  19. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method.

    Science.gov (United States)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-11-01

    Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method.

  20. Ophthalmic public health; the way ahead.

    Science.gov (United States)

    Heidary, F; Rahimi, A; Gharebaghi, R

    2012-01-01

    Visual sciences have been progressing quickly in recent decades through globalization phenomenon. An enormous change has taken place in ocular health issues, however, there are various problems facing ophthalmic public health worldwide. In the previous years, the World Health Organization and the International Agency for the Prevention of Blindness in partnership launched the global initiative to eradicate avoidable blindness by the year 2020, VISION 2020 the Right to Sight. It has concentrated on the prevention of blindness disability and recognized a health issue-sight as a human right. In view of challenges ahead of visual sciences, close collaboration between international agencies at the global level to implement new strategies and monitor the progress will be mandatory. In these circumstances non-governmental organizations should not be neglected. World Sight Day 2012 would be a great opportunity to be a focus on importance of visual impairment as an important public health issue and discovering new challenges ahead.

  1. High-intensity xenon plasma discharge lamp for bulk-sensitive high-resolution photoemission spectroscopy.

    Science.gov (United States)

    Souma, S; Sato, T; Takahashi, T; Baltzer, P

    2007-12-01

    We have developed a highly brilliant xenon (Xe) discharge lamp operated by microwave-induced electron cyclotron resonance (ECR) for ultrahigh-resolution bulk-sensitive photoemission spectroscopy (PES). We observed at least eight strong radiation lines from neutral or singly ionized Xe atoms in the energy region of 8.4-10.7 eV. The photon flux of the strongest Xe I resonance line at 8.437 eV is comparable to that of the He Ialpha line (21.218 eV) from the He-ECR discharge lamp. Stable operation for more than 300 h is achieved by efficient air-cooling of a ceramic tube in the resonance cavity. The high bulk sensitivity and high-energy resolution of PES using the Xe lines are demonstrated for some typical materials.

  2. Congenital glaucoma as an ophthalmic manifestation of Frank-Ter Haar syndrome.

    Science.gov (United States)

    Aktas, Zeynep; Karaca, Emine Esra; Dogan, Nurcan; Çakmak, Tugba; Unlu, Metin; Tok, Levent; Hasanreisoglu, Murat

    2014-04-01

    We report on a patient with Frank-Ter Haar syndrome that is associated with high intraocular pressures. A 21-day-old male patient was referred to our clinic for surgical treatment of congenital glaucoma. On ophthalmic examination, he had buphthalmos, mild corneal edema and high IOP readings in both eyes. The patient underwent uneventful trabeculotomy surgery, bilaterally. Marked bilateral anterior iris insertion was noted during the surgery. Childhood glaucoma may be associated with Frank-Ter Haar syndrome.

  3. Study on reactor building structure using ultrahigh strength materials - Part 9: Summary of the study

    International Nuclear Information System (INIS)

    Tanaka, H.; Odajima, M.; Irino, K.; Hashiba, T.

    1993-01-01

    Considerations for longevity of nuclear facilities and ease of decommissioning are of great importance for future nuclear power plants. To this end, a concept of an optimal structural concept for nuclear reactor buildings has been studied: the main feature of this concept is to utilize large-sized, light weight prefabricated members with ultrahigh strength materials. The following two items have been selected to study the prospective structure: (1) Applicability of ultrahigh strength materials for reinforced concrete shear walls (2) Construction using large sized prefabricated members As the first step (1), material and structural tests using ultrahigh strength materials, and the subsequent analysis of those tests for reinforced concrete shear walls, has been conducted. The positive results of this study show a bright future for the use of ultrahigh strength materials for the reinforced concrete shear walls of nuclear reactor buildings. As the second step (2), tests on a mixed structure with precasted members have been conducted. Our results positively suggest the use of these materials and methods to improve prospective nuclear power plants. (author)

  4. To study the existing system of surgical safety for cataract surgery at tertiary care ophthalmic centre to implement WHO surgical safety checklist

    OpenAIRE

    Ruchi Garg; Neeraj Garg; Shakti Kumar Gupta; J. S. Titiyal; R. Mahesh

    2016-01-01

    Background: Dr. Rajendra Prasad Centre for Ophthalmic Sciences, named after the first President of India, was established on the 10th of March, 1967 as a National centre for ophthalmic science, to provide state of the art patient care, expand human resources for medical education and undertake research to find solutions to eye health problems of national importance. Average numbers of cataract surgeries performed per month are 700 to 1000. Methods: Anticipating implementation in 50% cases...

  5. Three-dimensional Hessian matrix-based quantitative vascular imaging of rat iris with optical-resolution photoacoustic microscopy in vivo

    Science.gov (United States)

    Zhao, Huangxuan; Wang, Guangsong; Lin, Riqiang; Gong, Xiaojing; Song, Liang; Li, Tan; Wang, Wenjia; Zhang, Kunya; Qian, Xiuqing; Zhang, Haixia; Li, Lin; Liu, Zhicheng; Liu, Chengbo

    2018-04-01

    For the diagnosis and evaluation of ophthalmic diseases, imaging and quantitative characterization of vasculature in the iris are very important. The recently developed photoacoustic imaging, which is ultrasensitive in imaging endogenous hemoglobin molecules, provides a highly efficient label-free method for imaging blood vasculature in the iris. However, the development of advanced vascular quantification algorithms is still needed to enable accurate characterization of the underlying vasculature. We have developed a vascular information quantification algorithm by adopting a three-dimensional (3-D) Hessian matrix and applied for processing iris vasculature images obtained with a custom-built optical-resolution photoacoustic imaging system (OR-PAM). For the first time, we demonstrate in vivo 3-D vascular structures of a rat iris with a the label-free imaging method and also accurately extract quantitative vascular information, such as vessel diameter, vascular density, and vascular tortuosity. Our results indicate that the developed algorithm is capable of quantifying the vasculature in the 3-D photoacoustic images of the iris in-vivo, thus enhancing the diagnostic capability of the OR-PAM system for vascular-related ophthalmic diseases in vivo.

  6. Safety and efficacy of topical azithromycin ophthalmic solution 1.0% in the treatment of contact lens-related dry eye.

    Science.gov (United States)

    Nichols, Jason J; Bickle, Katherine M; Zink, Richard C; Schiewe, Michael D; Haque, Reza M; Nichols, Kelly K

    2012-03-01

    The purpose of this pilot study was to evaluate the safety and efficacy of azithromycin ophthalmic solution 1% in patients with contact lens-related dry eye (CLDE). This was a 4-week, single-center, open-label clinical trial in patients diagnosed with CLDE using the Contact Lens Dry Eye Questionnaire (CLDEQ). Fifty patients were enrolled in this study. The patients were randomized to 1 of 2 treatment groups: azithromycin ophthalmic solution administered bid on days 1 and 2 and on days 3 to 29±1 or Visine for Contacts rewetting drops administered qid on days 1 to 29±1. The patient diaries were used daily to collect data on comfortable and total contact lens wear time and ocular dryness throughout the treatment period. Tear osmolarity, fluorescein corneal staining, and visual acuity were also assessed during clinic visits. Fifty patients were enrolled, and 44 completed the study. One patient discontinued in the azithromycin group, and five patients discontinued in the rewetting drops group because of adverse events. A statistically significant increase in mean comfortable contact lens wear time from baseline was observed for the subjects treated with azithromycin ophthalmic solution as compared with the subjects treated with rewetting drops at week 4 (P=0.004; primary endpoint), in addition to weeks 2 and 3. The improvement in the mean comfortable wear time for the patients in the azithromycin treatment group exceeded 2 hrs throughout the treatment period (weeks 1-4). No significant differences were observed between the groups for total wear time, low contrast visual acuity, or tear osmolarity. Subject-rated ocular dryness (PM time assessments) was significantly improved from baseline in the subjects treated with azithromycin ophthalmic solution as compared with those treated with rewetting drops at weeks 2 and 3 endpoints (P=0.015 for each week). Additionally, a statistical difference was observed in favor of the azithromycin treatment group at week 2 for the

  7. Three percent diquafosol ophthalmic solution as an additional therapy to existing artificial tears with steroids for dry-eye patients with Sjögren's syndrome.

    Science.gov (United States)

    Yokoi, N; Sonomura, Y; Kato, H; Komuro, A; Kinoshita, S

    2015-09-01

    To investigate the long-term results of 3% diquafosol ophthalmic solution as an alternative therapy to existing ophthalmic solutions, including topical immunosuppression, for the treatment of dry eye in patients with Sjögren's syndrome. This study involved 14 female dry-eye patients (mean age: 62.4 years) with Sjögren's syndrome who insufficiently responded to their current therapy. In all patients, 3% diquafosol ophthalmic solution was administered six times daily for 12 months in substitution for artificial tears and sodium hyaluronate ophthalmic solution. Their use of corticosteroid eye drops remained unchanged from that prior to the treatment with diquafosol sodium. The subjective symptoms assessed, and ocular signs including tear meniscus radius and the tear film breakup time, and ocular-surface epithelial damage score were examined at 1, 2, 3, 4, 5, 6, 9, and 12 months after initiating treatment. Among the subjective symptoms, significant improvement was obtained in dryness at 2 months post treatment, in eye fatigue at 1, 2, 3, 4, and 12 months post treatment, and in pain at 1, 2, 6, and 12 months post treatment. Difficulty in opening the eye, foreign body sensation, and redness were also significantly ameliorated at various time-points. The tear meniscus radius and the tear film breakup time were significantly improved throughout the observation period, and the corneal epithelial staining scores were significantly decreased at 3 months post treatment. In dry-eye patients with Sjögren's syndrome, treatment with 3% diquafosol ophthalmic solution improved both symptoms and signs, and that effectiveness was maintained for 12 months.

  8. Comparative studies of various hyaluronic acids produced by microbial fermentation for potential topical ophthalmic applications

    DEFF Research Database (Denmark)

    Guillaumie, Fanny; Furrer, Pascal; Felt-Baeyens, Olivia

    2010-01-01

    This work presents a comparative study of various hyaluronic acids (HA) produced by fermentation of either Bacillus subtilis or Streptococcus towards the selection of an optimal molecular weight (MW) HA for the preparation of topical ophthalmic formulations. The influence of HA MW on water binding...

  9. In vivo High Angular Resolution Diffusion-Weighted Imaging of Mouse Brain at 16.4 Tesla

    OpenAIRE

    Alomair, Othman I.; Brereton, Ian M.; Smith, Maree T.; Galloway, Graham J.; Kurniawan, Nyoman D.

    2015-01-01

    Magnetic Resonance Imaging (MRI) of the rodent brain at ultra-high magnetic fields (> 9.4 Tesla) offers a higher signal-to-noise ratio that can be exploited to reduce image acquisition time or provide higher spatial resolution. However, significant challenges are presented due to a combination of longer T 1 and shorter T 2/T2* relaxation times and increased sensitivity to magnetic susceptibility resulting in severe local-field inhomogeneity artefacts from air pockets and bone/brain interfaces...

  10. [Reparative Osteogenesis and Angiogenesis in Low Intensity Electromagnetic Radiation of Ultra-High Frequency].

    Science.gov (United States)

    Iryanov, Y M; Kiryanov, N A

    2015-01-01

    Non-drug correction of reparative bone tissue regeneration in different pathological states - one of the most actual problems of modern medicine. Our aim was to conduct morphological analysis of the influence of electromagnetic radiation of ultra-high frequency and low intensity on reparative osteogenesis and angiogenesis in fracture treatment under transosseous osteosynthesis. A controlled nonrandomized study was carried out. In the experiment conducted on rats we modeled tibial fracture with reposition and fixation of the bone fragments both in control and experimental groups. In the animals of the experimental group the fracture zone was exposed to low intensity electromagnetic radiation of ultra-high frequency. Exposure simulation was performed in the control group. The operated bones were examined using radiography, light and electronic microscopy, X-ray electronic probe microanalysis. It has been established that electromagnetic radiation of ultra-high frequency sessions in fracture treatment stimulate secretory activity and degranulation of mast cells, produce microcirculatory bed vascular permeability increase, endotheliocyte migration phenotype expression, provide endovascular endothelial outgrowth formation, activate reparative osteogenesis and angiogenesis while fracture reparation becomes the one of the primary type. The full periosteal, intermediary and intraosteal bone union was defined in 28 days. Among the therapeutic benefits of electromagnetic radiation of ultra-high frequency in fracture treatment we can detect mast cell secretorv activity stimulation and endovascular anziozenesis activation.

  11. Ultra-high pressure water jet: Baseline report

    International Nuclear Information System (INIS)

    1997-01-01

    The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is recommended because of the outdoor environment where the testing demonstration took place. In addition, other areas of concern found were arm-hand vibration, ergonomics, heat stress, tripping hazards, electrical hazards, lockout/tagout, fall hazards, slipping hazards, hazards associated with the high pressure water, and hazards associated with air pressure systems

  12. Enantioseparation of dansyl amino acids by ultra-high pressure liquid chromatography using cationic β-cyclodextrins as chiral additives.

    Science.gov (United States)

    Xiao, Yin; Tan, Timothy Thatt Yang; Ng, Siu-Choon

    2011-04-07

    This work reports the application of ultra-high pressure liquid chromatography (UHPLC) for reasonably fast enantiorecognition of some dansyl amino acids by employing three cationic β-cyclodextrins (β-CDs) as chiral additives. Good resolutions were obtained on an Agilent C18 column (2.1 mm i.d.; 1.8 μm; 50 mm length) with 1% (v/v) triethylammonium acetate buffered at pH 4.7 and acetonitrile as the mobile phase. Most of the analytes could be baseline resolved within 10 min. Increased cationic CD concentration or acetonitrile proportion in the mobile phase results in a decreased retention factor but accentuated selectivity. Furthermore, molecular mechanics calculation was performed and found to be consistent with the experimental results. © The Royal Society of Chemistry 2011

  13. Vascular resistance of central retinal and ophthalmic arteries in postmenopausal women after use of tibolone.

    Science.gov (United States)

    de Souza, Marco Aurélio Martins; de Souza, Bruno Martins; Geber, Selmo

    2012-03-01

    The aim of this study was to evaluate the effect of tibolone on vascular resistance of the central retinal and ophthalmic artery in postmenopausal women and to compare this effect with that of placebo using transorbital ultrasound with Doppler velocimetry. We performed a prospective randomized, double-blinded, placebo-controlled study. A total of 100 healthy postmenopausal women (follicle-stimulating hormone, >40 IU/L) younger than 65 years were studied. The participants were randomly allocated to two groups: placebo (n = 50) and tibolone (2.5 mg; n = 50). Transorbital Doppler velocimetric ultrasound was performed before treatment and 80 days after. The mean age was similar in both groups. Participants who received tibolone did not show any difference in pulsatility index, resistance index, and systole/diastole ratio of the central retinal and ophthalmic arteries after treatment. The same was observed in participants who received placebo. Our study demonstrates that tibolone administration to healthy postmenopausal women does not affect the resistance of small-caliber cerebral arteries.

  14. Oriented nanocomposites of ultrahigh-molecular-weight polyethylene and gold

    NARCIS (Netherlands)

    Heffels, W.; Bastiaansen, C.W.M.; Caseri, W.R.; Smith, P.

    2000-01-01

    Polymer nanocomposites were prepd. by mixing ultrahigh-mol.-wt. polyethylene and gold colloids coated with a self-assembled monolayer of dodecanethiol. Subsequently, these materials were oriented by solid state drawing which induced the formation of uniaxially oriented arrays of gold particles. As a

  15. Safety in the use of compressed air versus oxygen for the ophthalmic patient.

    Science.gov (United States)

    Rodgers, Laura A; Kulwicki, Anahid

    2002-02-01

    Oxygen, routinely administered during surgery to avoid hypoxia, poses risks including increased likelihood of surgical room fires and predisposition to retinal phototoxicity in patients. Compressed air to supplement ventilation may be safer than oxygen. The purpose of this study was to determine whether hypoxia occurs more frequently when compressed air replaces supplemental oxygen during ophthalmic surgery. A convenience sample of 111 patients was randomly assigned to receive supplemental oxygen (group 1) or compressed air (group 2). Patients with serious cardiac or pulmonary disease were excluded. Blood oxygen levels were monitored during surgery by pulse oximetry. Oxygen was administered to all group 2 patients whose oxygen saturation fell to less than 90% or by more than 5% below baseline. No differences were observed between groups in age, ASA classification, type of surgery, or anesthetic drugs or doses. Minor, but statistically higher oxygen values were observed in group 1. The frequency with which oxygen saturation decreased below 90% or below 5% of baseline was similar in both groups. Supplemental oxygen is not required routinely in selected patients undergoing ophthalmic surgery. By using compressed air, the risk of operating room fires and retinal phototoxicity may be reduced.

  16. Polyethylene Naphthalate Scintillator: A Novel Detector for the Dosimetry of Radioactive Ophthalmic Applicators.

    Science.gov (United States)

    Flühs, Dirk; Flühs, Andrea; Ebenau, Melanie; Eichmann, Marion

    2015-09-01

    Dosimetric measurements in small radiation fields with large gradients, such as eye plaque dosimetry with β or low-energy photon emitters, require dosimetrically almost water-equivalent detectors with volumes of <1 mm(3) and linear responses over several orders of magnitude. Polyvinyltoluene-based scintillators fulfil these conditions. Hence, they are a standard for such applications. However, they show disadvantages with regard to certain material properties and their dosimetric behaviour towards low-energy photons. Polyethylene naphthalate, recently recognized as a scintillator, offers chemical, physical and basic dosimetric properties superior to polyvinyltoluene. Its general applicability as a clinical dosimeter, however, has not been shown yet. To prove this applicability, extensive measurements at several clinical photon and electron radiation sources, ranging from ophthalmic plaques to a linear accelerator, were performed. For all radiation qualities under investigation, covering a wide range of dose rates, a linearity of the detector response to the dose was shown. Polyethylene naphthalate proved to be a suitable detector material for the dosimetry of ophthalmic plaques, including low-energy photon emitters and other small radiation fields. Due to superior properties, it has the potential to replace polyvinyltoluene as the standard scintillator for such applications.

  17. High-resolution X-ray crystal structure of bovine H-protein using the high-pressure cryocooling method

    International Nuclear Information System (INIS)

    Higashiura, Akifumi; Ohta, Kazunori; Masaki, Mika; Sato, Masaru; Inaka, Koji; Tanaka, Hiroaki; Nakagawa, Atsushi

    2013-01-01

    Using the high-pressure cryocooling method, the high-resolution X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. This is the first ultra-high-resolution structure obtained from a high-pressure cryocooled crystal. Recently, many technical improvements in macromolecular X-ray crystallography have increased the number of structures deposited in the Protein Data Bank and improved the resolution limit of protein structures. Almost all high-resolution structures have been determined using a synchrotron radiation source in conjunction with cryocooling techniques, which are required in order to minimize radiation damage. However, optimization of cryoprotectant conditions is a time-consuming and difficult step. To overcome this problem, the high-pressure cryocooling method was developed (Kim et al., 2005 ▶) and successfully applied to many protein-structure analyses. In this report, using the high-pressure cryocooling method, the X-ray crystal structure of bovine H-protein was determined at 0.86 Å resolution. Structural comparisons between high- and ambient-pressure cryocooled crystals at ultra-high resolution illustrate the versatility of this technique. This is the first ultra-high-resolution X-ray structure obtained using the high-pressure cryocooling method

  18. Bimatoprost 0.03% preservative-free ophthalmic solution versus bimatoprost 0.03% ophthalmic solution (Lumigan) for glaucoma or ocular hypertension: a 12-week, randomised, double-masked trial

    Science.gov (United States)

    Day, Douglas G; Walters, Thomas R; Schwartz, Gail F; Mundorf, Thomas K; Liu, Charlie; Schiffman, Rhett M; Bejanian, Marina

    2013-01-01

    Background/Aim To evaluate efficacy and safety of bimatoprost 0.03% preservative-free (PF) ophthalmic solution versus bimatoprost 0.03% (Lumigan) ophthalmic solution for glaucoma or ocular hypertension. Methods In this double-masked, parallel-group study, patients were randomised to bimatoprost PF or bimatoprost for 12 weeks. The primary analysis for non-inferiority was change from baseline in worse eye intraocular pressure (IOP) in the per-protocol population at week 12. For equivalence, it was average eye IOP in the intent-to-treat population at each time point at weeks 2, 6 and 12. Results 597 patients were randomised (bimatoprost PF, n=302 and bimatoprost, n=295). The 95% CI upper limit for worse eye IOP change from baseline was <1.5 mm Hg at each week 12 time point, meeting prespecified non-inferiority criteria. The 95% CI upper limit for the treatment difference for average IOP was 0.69 mm Hg and the lower limit was −0.50 mm Hg at all follow-up time points (hours 0, 2 and 8 at weeks 2, 6 and 12), meeting equivalence criteria. Both treatments showed decreases in mean average eye IOP at all follow-up time points (p<0.001), were safe and well tolerated. Conclusions Bimatoprost PF is non-inferior and equivalent to bimatoprost in its ability to reduce IOP-lowering with a safety profile similar to bimatoprost. PMID:23743437

  19. A Case of Hydranencephaly in Which Ophthalmic Examinations Were Performed

    Directory of Open Access Journals (Sweden)

    Shohei Eda

    2016-09-01

    Full Text Available Purpose: We performed ophthalmic examinations, including optical coherence tomography (OCT, on a case diagnosed with hydranencephaly. Case Report: This case involved a female infant born at the gestational age of 35 weeks and 4 days, with the birth weight of 2,152 g, who was one of monochorionic diamniotic twins, and the identical twin died in utero at the gestational age of 24 weeks. After that, examination by fetal echo indicated that she had microcephaly and ventriculomegaly. Postnatal magnetic resonance imaging (MRI of her head indicated microcephaly and significant enlargement of the lateral ventricle on both sides, with no obvious signs of elevated intracranial pressure. The brain parenchyma of both sides of the frontal lobe, parietal lobe, and occipital lobe had marked thinning, yet that of the temporal lobe, basal ganglia, thalamus, brain stem, and cerebellum had been maintained. Moreover, no obvious hematoma or neoplastic lesions were observed. Ophthalmic examinations indicated that both of her eyes had slight light reflex, attributed to optic nerve atrophy. Examination by use of a hand-held OCT system indicated a layered structure of the retina and thinning of the ganglion cell layer. Flicker electroretinogram (ERG examination by use of a hand-held ERG system indicated an almost normal wave. However, no clear visual reaction was observed when she was 10 months old. Conclusion: Our findings in this case of hydranencephaly revealed that even though the outer layer functions of the patient’s retina were maintained, extensive damage to her cerebral cortex resulted in poor visual function.

  20. Fiber based hydrophones for ultra-high energy neutrino detection

    NARCIS (Netherlands)

    Buis, E.J.; Doppenberg, E.J.J.; Eijk, D. van; Lahmann, R.; Nieuwland, R.A.; Toet, P.M.

    2014-01-01

    It is a well studied process [1, 2] that energy deposition of cosmic ray particles in water that generate thermo-acoustic signals. Hydrophones of sufficient sensitivity could measure this signal and provide a means of detecting ultra-high energetic cosmic neutrinos. We investigate optical

  1. High spatial resolution and temporally resolved T2* mapping of normal human myocardium at 7.0 Tesla: an ultrahigh field magnetic resonance feasibility study.

    Directory of Open Access Journals (Sweden)

    Fabian Hezel

    Full Text Available Myocardial tissue characterization using T(2(* relaxation mapping techniques is an emerging application of (preclinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T(2(* mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T(2(* imaging at 7.0 T and examines the applicability of temporally-resolved and high spatial resolution myocardial T(2(* mapping. In phantom experiments single cardiac phase and dynamic (CINE gradient echo imaging techniques provided similar T(2(* maps. In vivo studies showed that the peak-to-peak B(0 difference following volume selective shimming was reduced to approximately 80 Hz for the four chamber view and mid-ventricular short axis view of the heart and to 65 Hz for the left ventricle. No severe susceptibility artifacts were detected in the septum and in the lateral wall for T(2(* weighting ranging from TE = 2.04 ms to TE = 10.2 ms. For TE >7 ms, a susceptibility weighting induced signal void was observed within the anterior and inferior myocardial segments. The longest T(2(* values were found for anterior (T(2(* = 14.0 ms, anteroseptal (T(2(* = 17.2 ms and inferoseptal (T(2(* = 16.5 ms myocardial segments. Shorter T(2(* values were observed for inferior (T(2(* = 10.6 ms and inferolateral (T(2(* = 11.4 ms segments. A significant difference (p = 0.002 in T(2(* values was observed between end-diastole and end-systole with T(2(* changes of up to approximately 27% over the cardiac cycle which were pronounced in the septum. To conclude, these results underscore the challenges of myocardial T(2(* mapping at 7.0 T but demonstrate that these issues can be offset by using tailored shimming techniques and dedicated acquisition schemes.

  2. Ultrahigh energy cosmic rays from nearby starburst galaxies

    Science.gov (United States)

    Attallah, Reda; Bouchachi, Dallel

    2018-04-01

    Ultrahigh energy cosmic rays are the most energetic of any subatomic particles ever observed in nature. The quest for their mysterious origin is currently a major scientific challenge. Here we explore the possibility that these particles originate from nearby starburst galaxies, a scenario that matches the recent observation by the Telescope Array experiment of a cosmic-ray hotspot above 57 EeV not far from the direction of the starburst galaxy M82. Specifically, we study the stochastic propagation in space of ultrahigh energy cosmic rays through the state-of-the-art simulation framework CRPropa 3, taking into account all relevant particle interactions as well as deflections by the intervening magnetic fields. To ensure a comprehensive understanding of this model, we consider the energy spectrum, the cosmogenic neutrinos and gamma rays, and the distribution of arrival directions. The starburst galaxy scenario reproduces well observations from both the Telescope Array and Pierre Auger Observatories, making it very attractive for explaining the origin of cosmic rays at the highest energies.

  3. Ophthalmic evaluation of long-term survivors of childhood acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Weaver, R.G. Jr.; Chauvenet, A.R.; Smith, T.J.; Schwartz, A.C.

    1986-01-01

    Thirty-four long-term survivors of childhood acute lymphoblastic leukemia (ALL) underwent comprehensive ophthalmic examinations to detect retinopathy or other ocular sequelae. Sixteen of the 34 patients received whole brain radiation (greater than or equal to 2400 rad). All 18 patients in the non-radiated group had normal eye examinations, while 4 of 16 in the radiated group had ocular abnormalities. None of the ocular abnormalities could be definitely attributed to radiation and all patients had normal visual acuity. No radiation retinopathy was found in either group

  4. A scanning tunneling microscope with a scanning range from hundreds of micrometers down to nanometer resolution.

    Science.gov (United States)

    Kalkan, Fatih; Zaum, Christopher; Morgenstern, Karina

    2012-10-01

    A beetle type stage and a flexure scanning stage are combined to form a two stages scanning tunneling microscope (STM). It operates at room temperature in ultrahigh vacuum and is capable of scanning areas up to 300 μm × 450 μm down to resolution on the nanometer scale. This multi-scale STM has been designed and constructed in order to investigate prestructured metallic or semiconducting micro- and nano-structures in real space from atomic-sized structures up to the large-scale environment. The principle of the instrument is demonstrated on two different systems. Gallium nitride based micropillars demonstrate scan areas up to hundreds of micrometers; a Au(111) surface demonstrates nanometer resolution.

  5. Ophthalmic comlications of functional endoscopic sinus surgery

    Directory of Open Access Journals (Sweden)

    Sergey A. Karpishchenko

    2017-03-01

    Full Text Available Functional endoscopic sinus surgery (FESS is an effective and safe surgical technique, which revolutionized the surgical management of nasal cavity and paranasal sinus diseases. The intimate connection between paranasal sinuses and the orbit places the orbital content at a risk of injury during sinus surgery, especially that of ethmoid sinuses. The orbit, the optic nerve, extraocular muscles and the lacrimal drainage system could be damaged during FESS. The risk of injury correlates to anatomical variations, degree and severity of disease, previous procedure results, and surgical experience. Ophthalmic complications can vary in severity from minor ones, such as localized hematomas, to extremely dangerous, such as optic nerve injury, that could lead to complete blindness. In order to minimize the risk of such complications, it is necessary to consider probable anatomic variations of paranasal sinuses and orbit, which are to be detected by CT scan before surgery.

  6. Probing physics at extreme energies with cosmic ultra-high energy ...

    Indian Academy of Sciences (India)

    testing new particle physics. Keywords. Ultra-high ... conventional theories of CR origin based on acceleration of charged particles in powerful ... Before discussing specific scenarios for UHECR origin we give a short account of the numerical ...

  7. High-resolution ultrahigh-pressure long column reversed-phase liquid chromatography for top-down proteomics

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Yufeng; Tolic, Nikola; Piehowski, Paul D.; Shukla, Anil K.; Kim, Sangtae; Zhao, Rui; Qu, Yi; Robinson, E. W.; Smith, Richard D.; Pasa-Tolic, Ljiljana

    2017-05-01

    We report development of an approach providing high-resolution RPLC of proteins and its utility for mass spectrometry-based top-down proteomics. A chromatographic peak capacity of ~450 was achieved for proteins and large polypeptides having MWs up to 43 kDa in the context of proteomics applications. RPLC column lengths from 20 to 200 cm, particle sizes from 1.5 to 5 m, bonding alkyl chains from C1 to C2, C4, C8, and C18, and particle surface structures that spanned porous, superficially porous (porous shell, core-shell), and nonporous were investigated at pressures up to14K psi. Column length was found as the most important factor for >20 kDa proteins in gradient RPLC, and shortening column length degraded RPLC resolution and sensitivity regardless of the size and surface structure of the packing particles used. The alkyl chains bonded to the silica particle surface significantly affected the RPLC recovery and efficiency, and short alkyl C1-C4 phases provided higher sensitivity and resolution than C8 and C18 phases. Long gradient separations (e.g., >10 hours) with long columns (e.g., 100 cm) were particularly effective in conjunction with use of high accuracy mass spectrometers (e.g., the Orbitrap Elite) for top-down proteomics with improved proteoform coverage by allowing multiple HCD, CID, and ETD dissociation modes. It was also found that HCD produced small fragments useful for proteoform identification, while low energy CID and ETD often complemented HCD by providing large fragments.

  8. Report on Ultra-high Resolution Gamma-/X-ray Analysis of Uranium Skull Oxide

    International Nuclear Information System (INIS)

    Friedrich, S.; Velazquez, M.; Drury, O.; Salaymeh, S.

    2009-01-01

    We have utilized the high energy resolution and high peak-to-background ratio of superconducting TES γ-detectors at very low energies for non-destructive analysis of a skull oxide derived from reprocessed nuclear fuel. Specifically, we demonstrate that superconducting detectors can separate and analyze the strong actinide emission lines in the spectral region below 60 keV that are often obscured in γ-measurements with conventional Ge detectors.

  9. Retinal protective effects of topically administered agmatine on ischemic ocular injury caused by transient occlusion of the ophthalmic artery

    Science.gov (United States)

    Hong, S.; Hara, H.; Shimazawa, M.; Hyakkoku, K.; Kim, C.Y.; Seong, G.J.

    2012-01-01

    Agmatine, an endogenous polyamine and putative neuromodulator, is known to have neuroprotective effects on various neurons in the central nervous system. We determined whether or not topically administered agmatine could reduce ischemic retinal injury. Transient ocular ischemia was achieved by intraluminal occlusion of the middle cerebral artery of ddY mice (30-35 g) for 2 h, which is known to also induce occlusion of the ophthalmic artery. In the agmatine group (N = 6), a 1.0 mM agmatine-containing ophthalmic solution was administered four times daily for 2 weeks before occlusion. In the control group (N = 6), a 0.1% hyaluronic acid ophthalmic solution was instilled at the same times. At 22 h after reperfusion, the eyeballs were enucleated and the retinal sections were stained by terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL). Transient ocular ischemia induced apoptosis of retinal cells in the entire retinal layer, and topically administered agmatine can significantly reduce this ischemic retinal injury. The proportion of apoptotic cells was definitely decreased (P agmatine application effectively decreases retinal damage in an in vivo ocular ischemic injury model. This implies that agmatine is a good candidate as a direct neuroprotective agent for eyes with ocular ischemic diseases. PMID:22331138

  10. Ophthalmic variables in rehabilitated juvenile Kemp's ridley sea turtles (Lepidochelys kempii).

    Science.gov (United States)

    Gornik, Kara R; Pirie, Christopher G; Marrion, Ruth M; Wocial, Julika N; Innis, Charles J

    2016-03-15

    To determine central corneal thickness (total corneal thickness [TCT], epithelial thickness [ET], and stromal thickness [ST]), anterior chamber depth (ACD), and intraocular pressure (IOP) in Kemp's ridley sea turtles (Lepidochelys kempii). Prospective cross-sectional study. 25 healthy rehabilitated juvenile Kemp's ridley sea turtles. PROCEDURES; Body weight and straight-line standard carapace length (SCL) were recorded. All turtles underwent a complete anterior segment ophthalmic examination. Central TCT, ET, ST, and ACD were determined by use of a spectral-domain optical coherence tomography device. Intraocular pressure was determined with a rebound tonometer; the horse setting was used to measure IOP in all 25 turtles, and the undefined setting was also used to measure IOP in 20 turtles. For each variable, 3 measurements were obtained bilaterally. The mean was calculated for each eye and used for analysis purposes. The mean ± SD body weight and SCL were 3.85 ± 1.05 kg (8.47 ± 2.31 lb) and 29 ± 3 cm, respectively. The mean ± SD TCT, ET, ST, and ACD were 288 ± 23 μm, 100 ± 6 μm, 190 ± 19 μm, and 581 ± 128 μm, respectively. Mean ± SD IOP was 6.5 ± 1.0 mm Hg when measured with the horse setting and 3.8 ± 1.1 mm Hg when measured with the undefined setting. Results provided preliminary reference ranges for objective assessment of ophthalmic variables in healthy juvenile Kemp's ridley sea turtles.

  11. Manganese oxide micro-supercapacitors with ultra-high areal capacitance

    Science.gov (United States)

    Wang, Xu; Myers, Benjamin D.; Yan, Jian; Shekhawat, Gajendra; Dravid, Vinayak; Lee, Pooi See

    2013-05-01

    A symmetric micro-supercapacitor is constructed by electrochemically depositing manganese oxide onto micro-patterned current collectors. High surface-to-volume ratio of manganese oxide and short diffusion distance between electrodes give an ultra-high areal capacitance of 56.3 mF cm-2 at a current density of 27.2 μA cm-2.A symmetric micro-supercapacitor is constructed by electrochemically depositing manganese oxide onto micro-patterned current collectors. High surface-to-volume ratio of manganese oxide and short diffusion distance between electrodes give an ultra-high areal capacitance of 56.3 mF cm-2 at a current density of 27.2 μA cm-2. Electronic supplementary information (ESI) available: Experimental procedures; optical images of micro-supercapacitors; areal capacitances of samples M-0.3C, M-0.6C and M-0.9C; illustration of interdigital finger electrodes; Nyquist plot of Co(OH)2 deposited on micro-electrodes. See DOI: 10.1039/c3nr00210a

  12. Modification of Ultra-High Vacuum Surfaces Using Free Radicals

    CERN Document Server

    Vorlaufer, G

    2002-01-01

    In ultra-high vacuum systems outgassing from vacuum chamber walls and desorption of surface adsorbates are usually the factors which determine pressure and residual gas composition. In particular in beam vacuum systems of accelerators like the LHC, where surfaces are exposed to intense synchrotron radiation and bombardment by energetic ions and electrons, surface properties like the molecular desorption yield or secondary electron yield can strongly influence the performance of the accelerator. Well-established treatment methods like vacuum bake-out or glow-discharge cleaning have been successfully applied in the past to condition ultra-high vacuum surfaces, but these methods are sometimes difficult to carry out, for example if the vacuum chambers are not accessible. In this work, an alternative treatment method is investigated. This method is based on the strong chemical reactivity of free radicals, electrically neutral fragments of molecules. Free radicals (in the case of this work, nitrogen and oxygen radi...

  13. Neuro-ophthalmic manifestation of neuromyelitis optica spectrum disorders

    Directory of Open Access Journals (Sweden)

    Xiao-jun ZHANG

    2014-10-01

    Full Text Available Neuromyelitis optica spectrum disorders (NMOSDs include classic neuromyelitis optica (NMO, opticospinal multiple sclerosis (OSMS, limited form of NMO and isolated optic neuritis or myelitis accompanied by either systemic autoimmune diseases or typical MRI findings of NMO. The common neuro-ophthalmic features of NMOSDs include simultaneous or consecutive bilateral optic neuritis, more commonly seen optic disk edema and surrounding exudate, poor visual recovery, steroid responsiveness and dependency. Combined with serum aquaporin 4 (AQP4 antibody and brain MRI examination, these clinical features can be helpful to the early differential diagnosis between NMOSDs and MS. Some types of eye movement abnormalities have been reported in patients with NMOSDs, but further investigation needs to be done before the specificity of these features are confirmed. doi: 10.3969/j.issn.1672-6731.2014.10.003

  14. Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER Study RESCAN Results.

    Science.gov (United States)

    Ehlers, Justis P; Goshe, Jeff; Dupps, William J; Kaiser, Peter K; Singh, Rishi P; Gans, Richard; Eisengart, Jonathan; Srivastava, Sunil K

    2015-10-01

    Optical coherence tomography (OCT) has transformed the clinical management of a myriad of ophthalmic conditions. Applying OCT to ophthalmic surgery may have implications for surgical decision making and patient outcomes. To assess the feasibility and effect on surgical decision making of a microscope-integrated intraoperative OCT (iOCT) system. Report highlighting the 1-year results (March 2014-February 2015) of the RESCAN 700 portion of the DISCOVER (Determination of Feasibility of Intraoperative Spectral Domain Microscope Combined/Integrated OCT Visualization During En Face Retinal and Ophthalmic Surgery) study, a single-site, multisurgeon, prospective consecutive case series regarding this investigational device. Participants included patients undergoing ophthalmic surgery. Data on clinical characteristics were collected, and iOCT was performed during surgical milestones, as directed by the operating surgeon. A surgeon questionnaire was issued to each surgeon and was completed after each case to evaluate the role of iOCT during surgery and its particular role in select surgical procedures. Percentage of cases with successful acquisition of iOCT (ie, feasibility). Percentage of cases in which iOCT altered surgical decision making (ie, utility). During year 1 of the DISCOVER study, a total of 227 eyes (91 anterior segment cases and 136 posterior segment cases) underwent imaging with the RESCAN 700 system. Successful imaging (eg, the ability to acquire an OCT image of the tissue of interest) was obtained for 224 of 227 eyes (99% [95% CI, 98%-100%]). During lamellar keratoplasty, the iOCT data provided information that altered the surgeon's decision making in 38% of the cases (eg, complete graft apposition when the surgeon believed there was interface fluid). In membrane peeling procedures, iOCT information was discordant with the surgeon's impression of membrane peel completeness in 19% of cases (eg, lack of residual membrane or presence of occult membrane), thus

  15. In vivo high resolution human corneal imaging using full-field optical coherence tomography.

    Science.gov (United States)

    Mazlin, Viacheslav; Xiao, Peng; Dalimier, Eugénie; Grieve, Kate; Irsch, Kristina; Sahel, José-Alain; Fink, Mathias; Boccara, A Claude

    2018-02-01

    We present the first full-field optical coherence tomography (FFOCT) device capable of in vivo imaging of the human cornea. We obtained images of the epithelial structures, Bowman's layer, sub-basal nerve plexus (SNP), anterior and posterior stromal keratocytes, stromal nerves, Descemet's membrane and endothelial cells with visible nuclei. Images were acquired with a high lateral resolution of 1.7 µm and relatively large field-of-view of 1.26 mm x 1.26 mm - a combination, which, to the best of our knowledge, has not been possible with other in vivo human eye imaging methods. The latter together with a contactless operation, make FFOCT a promising candidate for becoming a new tool in ophthalmic diagnostics.

  16. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I

    International Nuclear Information System (INIS)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-01-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  17. All-passive pixel super-resolution of time-stretch imaging

    Science.gov (United States)

    Chan, Antony C. S.; Ng, Ho-Cheung; Bogaraju, Sharat C. V.; So, Hayden K. H.; Lam, Edmund Y.; Tsia, Kevin K.

    2017-03-01

    Based on image encoding in a serial-temporal format, optical time-stretch imaging entails a stringent requirement of state-of-the-art fast data acquisition unit in order to preserve high image resolution at an ultrahigh frame rate — hampering the widespread utilities of such technology. Here, we propose a pixel super-resolution (pixel-SR) technique tailored for time-stretch imaging that preserves pixel resolution at a relaxed sampling rate. It harnesses the subpixel shifts between image frames inherently introduced by asynchronous digital sampling of the continuous time-stretch imaging process. Precise pixel registration is thus accomplished without any active opto-mechanical subpixel-shift control or other additional hardware. Here, we present the experimental pixel-SR image reconstruction pipeline that restores high-resolution time-stretch images of microparticles and biological cells (phytoplankton) at a relaxed sampling rate (≈2-5 GSa/s)—more than four times lower than the originally required readout rate (20 GSa/s) — is thus effective for high-throughput label-free, morphology-based cellular classification down to single-cell precision. Upon integration with the high-throughput image processing technology, this pixel-SR time-stretch imaging technique represents a cost-effective and practical solution for large scale cell-based phenotypic screening in biomedical diagnosis and machine vision for quality control in manufacturing.

  18. Analysis strategies for high-resolution UHF-fMRI data.

    Science.gov (United States)

    Polimeni, Jonathan R; Renvall, Ville; Zaretskaya, Natalia; Fischl, Bruce

    2018-03-01

    Functional MRI (fMRI) benefits from both increased sensitivity and specificity with increasing magnetic field strength, making it a key application for Ultra-High Field (UHF) MRI scanners. Most UHF-fMRI studies utilize the dramatic increases in sensitivity and specificity to acquire high-resolution data reaching sub-millimeter scales, which enable new classes of experiments to probe the functional organization of the human brain. This review article surveys advanced data analysis strategies developed for high-resolution fMRI at UHF. These include strategies designed to mitigate distortion and artifacts associated with higher fields in ways that attempt to preserve spatial resolution of the fMRI data, as well as recently introduced analysis techniques that are enabled by these extremely high-resolution data. Particular focus is placed on anatomically-informed analyses, including cortical surface-based analysis, which are powerful techniques that can guide each step of the analysis from preprocessing to statistical analysis to interpretation and visualization. New intracortical analysis techniques for laminar and columnar fMRI are also reviewed and discussed. Prospects for single-subject individualized analyses are also presented and discussed. Altogether, there are both specific challenges and opportunities presented by UHF-fMRI, and the use of proper analysis strategies can help these valuable data reach their full potential. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Bond behavior of reinforcing steel in ultra-high performance concrete.

    Science.gov (United States)

    2014-10-01

    Ultra-High Performance Concrete (UHPC) is a relatively new class of advanced cementitious composite : materials, which exhibits high compressive [above 21.7 ksi (150 MPa)] and tensile [above 0.72 ksi (5 MPa)] : strengths. The discrete steel fiber rei...

  20. Formulation and stability of an extemporaneous 0.02% chlorhexidine digluconate ophthalmic solution.

    Science.gov (United States)

    Lin, Shu-Chiao; Huang, Chih-Fen; Shen, Li-Jiuan; Wang, Hsueh-Ju; Lin, Chia-Yu; Wu, Fe-Lin Lin

    2015-12-01

    Acanthamoeba keratitis is difficult to treat because Acanthamoeba cysts are resistant to the majority of antimicrobial agents. Despite the efficacy of 0.02% chlorhexidine in treating Acanthamoeba keratitis, a lack of data in the literature regarding the formulation's stability limits its clinical use. The objective of this study was to develop an optimal extemporaneous 0.02% chlorhexidine digluconate ophthalmic formulation for patients in need. With available active pharmaceutical ingredients, 0.02% chlorhexidine digluconate sample solutions were prepared by diluting with BSS Plus Solution or acetate buffer. Influences of the buffer, type of container, and temperature under daily-open condition were assessed based on the changes of pH values and chlorhexidine concentrations of the test samples weekly. To determine the beyond-use date, the optimal samples were stored at 2-8°C or room temperature, and analyzed at time 0 and at Week 1, Week 2, Week 3, Week 4, Week 5, Week 8, Week 12, and Week 24. Despite chlorhexidine exhibiting better stability in acetate buffer than in BSS solution, its shelf-life was stability at 2-25°C for 6 months after being sealed and for 1 month after opening. This finding will enable us to prepare 0.02% chlorhexidine digluconate ophthalmic solutions based on a doctor's prescription. Copyright © 2014. Published by Elsevier B.V.

  1. Thermal characterization of Ag and Ag + N ion implanted ultra-high molecular weight polyethylene (UHMWPE)

    Science.gov (United States)

    Sokullu Urkac, E.; Oztarhan, A.; Tihminlioglu, F.; Kaya, N.; Ila, D.; Muntele, C.; Budak, S.; Oks, E.; Nikolaev, A.; Ezdesir, A.; Tek, Z.

    2007-08-01

    Most of total hip joints are composed of ultra-high molecular weight polyethylene (UHMWPE). However, as ultra-high molecular weight polyethylene is too stable in a body, wear debris may accumulate and cause biological response such as bone absorption and loosening of prosthesis. In this study, ultra-high molecular weight polyethylene samples were Ag and Ag + N hybrid ion implanted by using MEVVA ion implantation technique to improve its surface properties. Samples were implanted with a fluence of 1017 ion/cm2 and extraction voltage of 30 kV. Implanted and unimplanted samples were investigated by thermo-gravimetry analysis (TGA), differential scanning calorimetry (DSC), X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), optical microscopy (OM) and contact Angle measurement. Thermal characterization results showed that the ion bombardment induced an increase in the % crystallinity, onset and termination degradation temperatures of UHMWPE.

  2. Investigation of the imaging diagnosis on the ophthalmic orbital diseases

    International Nuclear Information System (INIS)

    Yoshizawa, Toshikazu

    1991-01-01

    Ultrasonographic examination, X-ray computerized tomography (CT) and magnetic resonance imaging (MRI) were performed on orbital diseases. Ultrasonographic examination was a simple, rapid and harmless noninvasive precedure as a diagnostic tool for evaluation of soft tissues. Echography was not more precise than X-ray CT and MRI scan in orbital diagnosis of the localization, size and well-defined outline of the lesion, relating to the peri- and retroorbital organs, however, was useful for screening study of an orbital lesion. B-mode of orbital tumors was effective for the ultrasonic diagnosis and classification according to four types; solid, cystic, angiomatous and infiltrative patterns. B-scan study of intraorbital inflammatory pseudo tumor could provide a differential diagnosis between inflammatory edema and an inflammatory mass lesion. Echographic pictures of dural arterio-venous fistula disclosed the vascular dilatation of superior ophthalmic vein and those of Basedow's disease with thickening of extraocular muscles. X-ray CT revealed intraorbital and intraocular disease, the globes and its immediate surrounding tissue (optic nerve, extraocular muscle, etc.) and bony orbital walls as the same slice of film. X-ray CT pictures of a coronal section, the contrast enhancement, calcification and destruction of the bone were helpful for diagnosis. However, the displays of disorders near the bone were ill-defined because of an artifact induced by high X-ray absorptive power of the bone. MRI was an equipment for superior contrast resolution, with provided a tomography of any section, without artifacts of the bone, and was the superior technique for displaying a vascular lesion. MRI of orbital disease was effective for reconstructing the spatial correlations between the lesion and its surounding tissues. MRI, however, provided no information of the skeleton, being not available for subjects with a magnetic substance. (author)

  3. Tomography system having an ultrahigh speed processing unit

    International Nuclear Information System (INIS)

    Cox, J.P. Jr.; Gerth, V.W. Jr.

    1977-01-01

    A transverse section tomography system has an ultrahigh-speed data processing unit for performing back projection and updating. An x-ray scanner directs x-ray beams through a planar section of a subject from a sequence of orientations and positions. The scanner includes a movably supported radiation detector for detecting the intensity of the beams of radiation after they pass through the subject

  4. Social cognition in patients at ultra-high risk for psychosis

    DEFF Research Database (Denmark)

    Glenthøj, Louise B.; Fagerlund, Birgitte; Hjorthøj, Carsten

    2016-01-01

    Objective: Patients at ultra-high risk (UHR) for psychosis show significant impairments in functioning. It is essential to determine which factors influence functioning, as it may have implications for intervention strategies. This study examined whether social cognitive abilities and clinical...

  5. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  6. Hydroxychloroquine screening practice patterns within a large multispecialty ophthalmic practice.

    Science.gov (United States)

    Au, Adrian; Parikh, Vishal; Modi, Yasha S; Ehlers, Justis P; Schachat, Andrew P; Singh, Rishi P

    2015-09-01

    To determine provider compliance with hydroxychloroquine screening following the revised recommendations published in 2011 by the American Academy of Ophthalmology. Evaluation of adherence to a screening protocol. Subjects were identified with hydroxychloroquine as a medication by electronic query at a large multispecialty ophthalmic practice. Patients were excluded if patients: (1) were screened by an outside physician; (2) lacked recorded height, weight, start date, or dosing; or (3) took hydroxychloroquine for malaria prophylaxis. Screening tests were stratified by ophthalmic subspecialty. Guidelines define proper screening as 1 subjective test-Humphrey visual field (HVF), and 1 objective test-spectral-domain optical coherence tomography (SD OCT), fundus autofluorescence (FAF), or multifocal electroretinography (mfERG). Adherence to guidelines was determined by categorizing practices as: (1) "appropriate"-consistent with guidelines; (2) "underscreened"-insufficient testing; or (3) "inappropriate"-no testing. The study comprised 756 patients with a mean age of 56 years undergoing 1294 screening visits. Twenty-one patients received initial screenings outside the institution. Most common screening tests employed included SD OCT (56.6%), 10-2 HVF (55.0%), and Amsler grid (40.0%). Of the 735 initial screenings, 341 (46.4%) were appropriately screened, 204 (27.8%) underscreened, and 190 (25.9%) inappropriately screened. Of those who presented solely for screening (560), 307 (54.8%) were appropriately screened, 144 (25.7%) underscreened, and 109 (19.5%) inappropriately screened. Of patients presenting for hydroxychloroquine screening, 54.8% of patients received appropriate evaluation, indicating lack of adherence to guidelines. Overall, SD OCT and 10-2 HVF were the preferred screening modalities, with FAF and mfERG less frequently ordered. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. [Pediatric case series in an ophthalmic camp in Turkana (Kenya)].

    Science.gov (United States)

    Noval, S; Cabrejas, L; Jarrín, E; Ruiz-Guerrero, M; Ciancas, E

    2013-12-01

    Turkana is the largest district in Kenya, situated in the Northwest of the country. It features a semi-nomadic population of 850,000. Around 60% of population lives below the poverty threshold. The ratio of doctors is 1:75,000 inhabitants. Five ophthalmologists took part in the last deployment in November. Local staff had previously selected the patients from the rural areas, as well as in Lodwar, the capital of the district. Of the 371 patients who attended the clinic, 128 required surgery. To describe the pediatric population attended to in the last «Turkana Eye Project» Camp. Description of the ophthalmic pathologies of the children seen in the clinic in this surgical camp, and the diagnostic and therapeutic options according to the limitations of the environment. Of the 371 patients, 54 were younger than 15 years old (14.5%). Four children had surgery (3.25% of the 128 patients). In 2 more cases surgery was the indicated but not performed. Therefore, of the total of 54 cases, 6 could be considered as surgical (11.1%), and 17 suffered ophthalmic problems other than refraction defects, or mild ocular surface pathologies: traumatic cataracts, neuropathies, impetigo, exophthalmos, retinal dystrophies, dermoid cysts, or nyctalopia. The etiology was traumatic in four of the 17 children (23.5%). Surgical camps are increasing in the developing countries. They are usually focused on particular pathologies, such as cataracts or trachoma. Our case series shows the importance of pediatric teams and the need to be prepared to face complex pediatric pathologies. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  8. Optimization of 125I ophthalmic plaque brachytherapy

    International Nuclear Information System (INIS)

    Astrahan, M.A.; Luxton, G.; Jozsef, G.; Liggett, P.E.; Petrovich, Z.

    1990-01-01

    Episcleral plaques containing 125 I sources are often used in the treatment of ocular melanoma. Within four years post-treatment, however, the majority of patients experience some visual loss due to radiation retinopathy. The high incidence of late complications suggests that careful treatment optimization may lead to improved outcome. The goal of optimization would be to reduce the magnitude of vision-limiting complications without compromising tumor control. We have developed a three-dimensional computer model for ophthalmic plaque therapy which permits us to explore the potential of various optimization strategies. One simple strategy which shows promise is to maximize the ratio of dose to the tumor apex (T) compared to dose to the macula (M). By modifying the parameters of source location, activity distribution, source orientation, and shielding we find that the calculated T:M ratio can be varied by a factor of 2 for a common plaque design and posterior tumor location. Margins and dose to the tumor volume remain essentially unchanged

  9. CHICSi - a compact ultra-high vacuum compatible detector system for nuclear reaction experiments at storage rings. II. Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Golubev, P.; Avdeichikov, V.; Carlen, L.; Jakobsson, B. E-mail: bo.jakobsson@kosufy.lu.se; Siwek, A.; Veldhuizen, E.J. van; Westerberg, L.; Whitlow, H.J

    2003-03-11

    We describe the detectors for identification of charged particles and fragments in CHICSi, a large solid angle multi-telescope system mounted inside an ultra-high vacuum (UHV), cluster-jet target chamber. CHICSi performs nuclear reaction experiments at storage rings. The telescopes consist of a first very thin, 10-14 {mu}m Si detector, a second 300 {mu}m (or possibly 500 {mu}m) ion implanted Si detector supplemented by a 6 mm GSO(Ce) scintillator read out by a photodiode (PD) or by a third 300 {mu}m Si detector. The telescopes provide full charge separation up to Z=17 and mass resolution up to A=9 in the energy range 0.7-60A MeV. The thin p-i-n diode detector, etched out from a 280 {mu}m Si wafer, and the GSO/PD detector, both exclusively developed for CHICSi, provide an energy resolution {<=}8%, while the standard 300 {mu}m detectors have {<=}2% energy resolution. Radiation stability of the Si detectors is confirmed up to an integrated flux of 10{sup 10} alpha particles. The GSO detector has 70% light collection efficiency with the optical coupling to the PD a simple open, 0.2 mm, gap. A new method, developed to perform absolute energy calibration for the GSO/PD detector is presented.

  10. CHICSi - a compact ultra-high vacuum compatible detector system for nuclear reaction experiments at storage rings. II. Detectors

    International Nuclear Information System (INIS)

    Golubev, P.; Avdeichikov, V.; Carlen, L.; Jakobsson, B.; Siwek, A.; Veldhuizen, E.J. van; Westerberg, L.; Whitlow, H.J.

    2003-01-01

    We describe the detectors for identification of charged particles and fragments in CHICSi, a large solid angle multi-telescope system mounted inside an ultra-high vacuum (UHV), cluster-jet target chamber. CHICSi performs nuclear reaction experiments at storage rings. The telescopes consist of a first very thin, 10-14 μm Si detector, a second 300 μm (or possibly 500 μm) ion implanted Si detector supplemented by a 6 mm GSO(Ce) scintillator read out by a photodiode (PD) or by a third 300 μm Si detector. The telescopes provide full charge separation up to Z=17 and mass resolution up to A=9 in the energy range 0.7-60A MeV. The thin p-i-n diode detector, etched out from a 280 μm Si wafer, and the GSO/PD detector, both exclusively developed for CHICSi, provide an energy resolution ≤8%, while the standard 300 μm detectors have ≤2% energy resolution. Radiation stability of the Si detectors is confirmed up to an integrated flux of 10 10 alpha particles. The GSO detector has 70% light collection efficiency with the optical coupling to the PD a simple open, 0.2 mm, gap. A new method, developed to perform absolute energy calibration for the GSO/PD detector is presented

  11. Safety of Lifitegrast Ophthalmic Solution 5.0% in Patients With Dry Eye Disease: A 1-Year, Multicenter, Randomized, Placebo-Controlled Study.

    Science.gov (United States)

    Donnenfeld, Eric D; Karpecki, Paul M; Majmudar, Parag A; Nichols, Kelly K; Raychaudhuri, Aparna; Roy, Monica; Semba, Charles P

    2016-06-01

    To evaluate the 1-year safety of lifitegrast ophthalmic solution 5.0% in patients with dry eye disease compared with placebo. SONATA (Safety Of a 5.0% coNcentrATion of lifitegrAst ophthalmic solution) was a multicenter, randomized, prospective, double-masked, placebo-controlled phase 3 study (NCT01636206). Adults (≥18 years) with dry eye disease (Schirmer test score ≥1 and ≤10 mm; corneal staining score ≥2.0) were randomized 2:1 to lifitegrast ophthalmic solution 5.0% or placebo twice daily for 360 days. The primary objective was percentage and severity of treatment-emergent adverse events (TEAEs). Secondary objectives were ocular safety measures: corneal fluorescein staining, drop comfort, best-corrected visual acuity, slit-lamp biomicroscopy, and intraocular pressure over 7 visits. Exploratory objectives included concentration of lifitegrast in plasma. The safety population comprised 331 participants (220 lifitegrast; 111 placebo). There were no serious ocular TEAEs. Overall, 53.6% of participants receiving lifitegrast experienced ≥1 ocular TEAE versus 34.2% in the placebo group; most TEAEs were mild to moderate in severity. Rates of discontinuation because of TEAEs were 12.3% (lifitegrast) versus 9.0% (placebo). The most common (>5%) TEAEs occurring in either treatment group were instillation site irritation (burning), instillation site reaction, visual acuity reduced, dry eye, and dysgeusia (change in taste). Ocular safety parameters for lifitegrast were similar to placebo. The mean plasma lifitegrast concentration at 360 days (n = 43) was below the limit of detection. There was no indication of systemic toxicity or localized infectious complications secondary to chronic immunosuppression. Lifitegrast ophthalmic solution 5.0% seemed safe and well tolerated in this study, with no unexpected adverse events.

  12. The Efficacy of 1% Chloramphenicol Eye Ointment Versus 2.5% Povidone-Iodine Ophthalmic Solution in Reducing Bacterial Colony in Newborn Conjunctivae.

    Science.gov (United States)

    Bramantyo, Triwijayanti; Roeslani, Rosalina Dewi; Andriansjah, Andriansjah; Sitorus, Rita S

    2015-01-01

    This study aimed to evaluate bacterial pattern and reduction of bacterial colonies in neonatal conjunctivae after prophylaxis 1% chloramphenicol eye ointment and 2.5% povidone-iodine ophthalmic solution. A double-blind randomized controlled trial was conducted. Swabs were taken from the inferior fornix conjunctiva of the right eyes of 60 newborns 1 hour after birth. Either the 2.5% povidone-iodine ophthalmic solution or the 1% chloramphenicol eye ointment was randomly applied to the conjunctivae. Conjunctival swabs were taken 2 hours after prophylaxis treatment. Specimens were delivered to the Microbiology Laboratory to determine the number of bacterial colonies and to evaluate bacterial pattern. Sixty eye specimens were included in the study. Bacterial growth was shown in 44 eye specimens, whereas it was not found in the remaining 16 eye specimens. The bacteria found in neonatal conjunctivae was gram-positive coccus (61%), followed by gram-positive bacillus (36%) and gram-negative bacillus (2%). Both agents significantly reduced the bacterial colony-forming unit (P = 0.00); however, the effect was not significantly different as shown by statistics between both groups (P = 0.748), indicating that the 2.5% povidone-iodine ophthalmic solution had a similar effect to the 1% chloramphenicol eye ointment. No adverse effect such as toxic conjunctivitis or corneal haziness was found in both groups. The 2.5% povidone-iodine ophthalmic solution has been proven as effective as the 1% chloramphenicol eye ointment and induces no toxic reaction. Because it is less expensive than the other, it could be recommended as a good alternative for ophthalmia neonatorum prophylaxis. Further studies with a larger sample size should be conducted to confirm its cost-effectiveness.

  13. Optical Analysis of an Ultra-High resolution Two-Mirror Soft X-Ray Microscope

    Science.gov (United States)

    Shealy, David L.; Wang, Cheng; Hoover, Richard B.

    1994-01-01

    This work has summarized for a Schwarzschild microscope some relationships between numerical aperture (NA), magnification, diameter of the primary mirror, radius of curvature of the secondary mirror, and the total length of the microscope. To achieve resolutions better than a spherical Schwarzschild microscope of 3.3 Lambda for a perfectly aligned and fabricated system. it is necessary to use aspherical surfaces to control higher-order aberrations. For an NA of 0.35, the aspherical Head microscope provides diffraction limited resolution of 1.4 Lambda where the aspherical surfaces differ from the best fit spherical surface by approximately 1 micrometer. However, the angle of incidence varies significantly over the primary and the secondary mirrors, which will require graded multilayer coatings to operate near peak reflectivities. For higher numerical apertures, the variation of the angle of incidence over the secondary mirror surface becomes a serious problem which must be solved before multilayer coatings can be used for this application. Tolerance analysis of the spherical Schwarzschild microscope has shown that water window operations will require 2-3 times tighter tolerances to achieve a similar performance for operations with 130 A radiation. Surface contour errors have been shown to have a significant impact on the MTF and must be controlled to a peak-to-valley variation of 50-100 A and a frequency of 8 periods over the surface of a mirror.

  14. Risk of Hemorrhage during Needle-Based Ophthalmic Regional Anesthesia in Patients Taking Antithrombotics: A Systematic Review.

    Directory of Open Access Journals (Sweden)

    Augusto Takaschima

    Full Text Available Patients undergoing ophthalmic surgery are usually elderly and, due to systemic disease, may be on long-term therapy, such as antithrombotic agents. Rates of hemorrhagic complications associated with invasive procedures may be increased by the use of anticoagulants and antiplatelet agents.To compare the incidence of hemorrhagic complications in patients undergoing needle-based ophthalmic regional anesthesia between patients on antithrombotic therapy and those not on such therapy.A systematic review was conducted by two independent reviewers based on searches of Cochrane, LILACS, PubMed, Scopus, Web of Science, and the "gray" literature (Google Scholar. The end search date was May 8, 2015, across all databases.Five studies met the eligibility criteria. In three studies, individual risk of bias was low, and in two of them, moderate. In all studies, no differences regarding mild to moderate incidence of hemorrhagic complications were found between patients using antithrombotics (aspirin, clopidogrel, and warfarin and those not using them. Rates of severe hemorrhagic complication were very low (0.04% in both groups, supporting the safety of needle blocks, even in patients using antithrombotics. High heterogeneity across studies prevented meta-analysis. Limitations to these results include low statistical power in three experimental studies and a large 95% confidence interval in the two retrospective cohorts.In this review, none of the selected studies showed significant bleeding related to needle-based ophthalmic regional anesthesia in association with the use of aspirin, clopidogrel, or vitamin K inhibitors. Since the available data is not powerful enough to provide a reliable evaluation of the true effect of antithrombotics in this setting, new studies to address these limitations are necessary.

  15. Ophthalmic nepafenac use in the Netherlands and Denmark

    DEFF Research Database (Denmark)

    Margulis, Andrea V.; Houben, Eline; Hallas, Jesper

    2017-01-01

    Purpose: To describe nepafenac use in the Netherlands and Denmark with reference to its approved indications. For context, we also describe the use of ketorolac and diclofenac. Methods: We identified users in the PHARMO Database Network (the Netherlands, 2008–2013) and the Danish national health...... registers (Denmark, 1994–2014). We described prevalence of cataract surgery and duration of use in patients with cataract surgery with and without diabetes. Results: In the Netherlands, 9530 nepafenac users (mean age, 71 years; 60% women) contributed 12 691 therapy episodes, of which 21% had a recently...... dispensed. Use patterns of nepafenac, ketorolac and diclofenac were roughly similar in the Netherlands, but not in Denmark. Conclusion: Less than half of therapy episodes were related to cataract surgery; around 90% of episodes with surgery were within the approved duration. Underrecording of ophthalmic...

  16. Ultra-high Efficiency DC-DC Converter using GaN Devices

    DEFF Research Database (Denmark)

    Ramachandran, Rakesh

    2016-01-01

    properties of GaN devices can be utilized in power converters to make them more compact and highly efficient. This thesis entitled “Ultra-high Efficiency DC-DC Converter using GaN devices” focuses on achieving ultra-high conversion efficiency in an isolated dc-dc converter by the optimal utilization of Ga...... for many decades. However, the rate of improvement slowed as the silicon power materials asymptotically approached its theoretical bounds. Compared to Si, wideband gap materials such as Silicon Carbide (SiC) and Gallium Nitride (GaN) are promising semiconductors for power devices due to their superior...... in this thesis. Efficiency measurements from the hardware prototype of both the topologies are also presented in this thesis. Finally, the bidirectional operation of an optimized isolated dc-dc converter is presented. The optimized converter has achieved an ultra-high efficiency of 98.8% in both directions...

  17. Thermal characterization of Ag and Ag + N ion implanted ultra-high molecular weight polyethylene (UHMWPE)

    Energy Technology Data Exchange (ETDEWEB)

    Sokullu Urkac, E. [Department of Materials Science, Izmir High Technology Institute, Gulbahcekoyu Urla, Izmir (Turkey)]. E-mail: emelsu@gmail.com; Oztarhan, A. [Bioengineering Department, Ege University, Bornova, Izmir 35100 (Turkey); Tihminlioglu, F. [Department of Chemical Engineering, Izmir High Technology Institute, Gulbahcekoyu Urla, Izmir (Turkey); Kaya, N. [Bioengineering Department, Ege University, Bornova, Izmir 35100 (Turkey); Ila, D. [Center for Irradiation of Materials, Alabama A and M University, Normal AL 35762 (United States); Muntele, C. [Center for Irradiation of Materials, Alabama A and M University, Normal AL 35762 (United States); Budak, S. [Center for Irradiation of Materials, Alabama A and M University, Normal AL 35762 (United States); Oks, E. [H C Electronics Institute, Tomsk (Russian Federation); Nikolaev, A. [H C Electronics Institute, Tomsk (Russian Federation); Ezdesir, A. [R and D Department, PETKIM Holding A.S., Aliaga, Izmir 35801 (Turkey); Tek, Z. [Department of Physics, Celal Bayar University, Manisa (Turkey)

    2007-08-15

    Most of total hip joints are composed of ultra-high molecular weight polyethylene (UHMWPE ). However, as ultra-high molecular weight polyethylene is too stable in a body, wear debris may accumulate and cause biological response such as bone absorption and loosening of prosthesis. In this study, ultra-high molecular weight polyethylene samples were Ag and Ag + N hybrid ion implanted by using MEVVA ion implantation technique to improve its surface properties. Samples were implanted with a fluence of 10{sup 17} ion/cm{sup 2} and extraction voltage of 30 kV. Implanted and unimplanted samples were investigated by thermo-gravimetry analysis (TGA), differential scanning calorimetry (DSC), X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), optical microscopy (OM) and contact Angle measurement. Thermal characterization results showed that the ion bombardment induced an increase in the % crystallinity, onset and termination degradation temperatures of UHMWPE.

  18. Ultrahigh energy neutrinos and nonlinear QCD dynamics

    International Nuclear Information System (INIS)

    Machado, Magno V.T.

    2004-01-01

    The ultrahigh energy neutrino-nucleon cross sections are computed taking into account different phenomenological implementations of the nonlinear QCD dynamics. Based on the color dipole framework, the results for the saturation model supplemented by the Dokshitzer-Gribov-Lipatov-Altarelli-Parisi (DGLAP) evolution as well as for the Balitskii-Fadin-Kuraev-Lipatov (BFKL) formalism in the geometric scaling regime are presented. They are contrasted with recent calculations using next-to-leading order DGLAP and unified BFKL-DGLAP formalisms

  19. Proton-proton elastic scattering at ultrahigh energies

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, M.; Shaukat, M.A.; Fazal-e-Aleem (University of the Punjab, Lahore (Pakistan). Dept. of Physics)

    1981-05-30

    Recent experimental results on proton-proton elastic scattering at high energies are discussed in the context of the comments by Chou and Yang. There does not appear to be any tendency that the experimental results would agree with the predictions of the geometrical model even at ultrahigh energies. The angular distribution structure as described by using the dipole pomeron is consistent with the experimental data at presently available high energies and predicts results quite different from the geometrical model.

  20. Effect of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye.

    Science.gov (United States)

    Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Oie, Yoshinori; Soma, Takeshi; Tsujikawa, Motokazu; Watanabe, Hitoshi; Nishida, Kohji

    2014-12-01

    To investigate the short- and long-term effects of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye. Sixteen eyes in 16 patients with mild or moderate aqueous-deficient dry eye were treated with 3% diquafosol ophthalmic solution. Ocular higher-order aberrations (HOAs) were measured with a wavefront sensor before and at 15 min after diquafosol instillation at the baseline visit and at 4 weeks after treatment initiation. Dry eye symptoms, tear break-up time (BUT), corneal/conjunctival fluorescein staining and Schirmer's test were also evaluated before and after treatment with diquafosol. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining and BUT. Compared with mean total HOAs at baseline (0.180 ± 0.06 μm), those at 4 weeks after treatment significantly decreased (0.148 ± 0.039 μm; p = 0.035), whereas those 15 min after diquafosol instillation at the baseline visit did not change significantly (0.170 ± 0.049 μm; p = 0.279). Although no significant change in HOAs was observed as a short-term effect of a single-drop instillation of diquafosol, long-term use of diquafosol to treat aqueous-deficient dry eye reduced HOAs as well as improved corneal epithelial damage and tear film stability. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. Retinal protective effects of topically administered agmatine on ischemic ocular injury caused by transient occlusion of the ophthalmic artery

    Directory of Open Access Journals (Sweden)

    S. Hong

    2012-03-01

    Full Text Available Agmatine, an endogenous polyamine and putative neuromodulator, is known to have neuroprotective effects on various neurons in the central nervous system. We determined whether or not topically administered agmatine could reduce ischemic retinal injury. Transient ocular ischemia was achieved by intraluminal occlusion of the middle cerebral artery of ddY mice (30-35 g for 2 h, which is known to also induce occlusion of the ophthalmic artery. In the agmatine group (N = 6, a 1.0 mM agmatine-containing ophthalmic solution was administered four times daily for 2 weeks before occlusion. In the control group (N = 6, a 0.1% hyaluronic acid ophthalmic solution was instilled at the same times. At 22 h after reperfusion, the eyeballs were enucleated and the retinal sections were stained by terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL. Transient ocular ischemia induced apoptosis of retinal cells in the entire retinal layer, and topically administered agmatine can significantly reduce this ischemic retinal injury. The proportion of apoptotic cells was definitely decreased (P < 0.001; Kruskal-Wallis test. Overall, we determined that topical agmatine application effectively decreases retinal damage in an in vivo ocular ischemic injury model. This implies that agmatine is a good candidate as a direct neuroprotective agent for eyes with ocular ischemic diseases.

  2. High resolution γ-ray spectroscopy: The first 85 years

    International Nuclear Information System (INIS)

    Deslattes, R.D.

    2000-01-01

    This opening review attempts to follow the main trends in crystal diffraction spectrometry of nuclear γ rays from its 1914 beginning in Rutherford's laboratory to the ultra-high resolution instrumentation realized in the current generation of spectrometers at the Institute Laue Langeven (ILL). The authors perspective is that of an instrumentalist hoping to convey a sense of intellectual debt to a number of predecessors, each of whom realized a certain elegance in making the tools that have enabled much good science, including that to which the remainder of this workshop is dedicated. This overview follows some of the main ideas along a trajectory toward higher resolution at higher energies, thereby enabling not only the disentangling of dense spectra, but also allowing detailed study of aspects of spectral profiles sensitive to excited state lifetimes and interatomic potentials. The parallel evolution toward increasing efficiency while preserving needed resolution is also an interesting story of artful compromise that should not be neglected. Finally, it is the robustness of the measurement chain connecting γ-ray wavelengths with optical wave-lengths associated with the Rydberg constant that only recently has allowed γ-ray data to contribute to determine of particle masses and fundamental constants, as will be described in more detail in other papers from this workshop

  3. Comparison of ophthalmic sponges and extraction buffers for quantifying cytokine profiles in tears using Luminex technology.

    Science.gov (United States)

    Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J; Barisani-Asenbauer, Talin

    2012-01-01

    Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1-EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous measurement of

  4. Comparison of ophthalmic sponges and extraction buffers for quantifying cytokine profiles in tears using Luminex technology

    Science.gov (United States)

    Inic-Kanada, Aleksandra; Nussbaumer, Andrea; Montanaro, Jacqueline; Belij, Sandra; Schlacher, Simone; Stein, Elisabeth; Bintner, Nora; Merio, Margarethe; Zlabinger, Gerhard J.

    2012-01-01

    Purpose Evaluating cytokine profiles in tears could shed light on the pathogenesis of various ocular surface diseases. When collecting tears with the methods currently available, it is often not possible to avoid the tear reflex, which may give a different cytokine profile compared to basal tears. More importantly, tear collection with glass capillaries, the most widely used method for taking samples and the best method for avoiding tear reflex, is impractical for remote area field studies because it is tedious and time-consuming for health workers, who cannot collect tears from a large number of patients with this method in one day. Furthermore, this method is uncomfortable for anxious patients and children. Thus, tears are frequently collected using ophthalmic sponges. These sponges have the advantage that they are well tolerated by the patient, especially children, and enable standardization of the tear collection volume. The aim of this study was to compare various ophthalmic sponges and extraction buffers to optimize the tear collection method for field studies for subsequent quantification of cytokines in tears using the Luminex technology. Methods Three ophthalmic sponges, Merocel, Pro-ophta, and Weck-Cel, were tested. Sponges were presoaked with 25 cytokines/chemokines of known concentrations and eluted with seven different extraction buffers (EX1–EX7). To assess possible interference in the assay from the sponges, two standard curves were prepared in parallel: 1) cytokines of known concentrations with the extraction buffers and 2) cytokines of known concentrations loaded onto the sponges with the extraction buffers. Subsequently, a clinical assessment of the chosen sponge-buffer combination was performed with tears collected from four healthy subjects using 1) aspiration and 2) sponges. To quantify cytokine/chemokine recovery and the concentration in the tears, a 25-plex Cytokine Panel and the Luminex xMap were used. This platform enables simultaneous

  5. A randomised, parallel-group comparison study of diquafosol ophthalmic solution in patients with dry eye in China and Singapore.

    Science.gov (United States)

    Gong, Lan; Sun, Xinghuai; Ma, Zhizhong; Wang, Qinmei; Xu, Xun; Chen, Xiaoming; Shao, Yan; Yao, Ke; Tang, Luosheng; Gu, Yangshun; Yuan, Huiping; Chua, Wei Han; Chuan, Jacob Cheng Yen; Tong, Louis

    2015-07-01

    To compare the efficacy and safety of 3% diquafosol ophthalmic solution with those of 0.1% sodium hyaluronate ophthalmic solution in patients with dry eye in China and Singapore. A total of 497 patients with dry eye (Schirmer's test, 5 mm; fluorescein and RB score, 3 points) from China and Singapore were randomised to receive either diquafosol ophthalmic solution (diquafosol) or sodium hyaluronate ophthalmic solution (HA) at 1:1 ratio. The fluorescein staining scores and rose bengal (RB) subjective symptom scores and tear film breakup time were evaluated before treatment and 2 and 4 weeks after start of treatment. In the diquafosol group, changes in fluorescein and RB scores compared with baseline at week 4 or at the time of discontinuation were -2.1±1.5 and -2.5±2.0, respectively. Compared with the HA group, changes in fluorescein score were non-inferior and changes in RB score were superior (p=0.019). In addition, diquafosol and HA improved tear film breakup time by 1.046±1.797 and 0.832±1.775 s, respectively (no significant intergroup difference). Adverse event onset rates were 16.3% (40 of 246 subjects) and 10.0% (25 of 251 subjects) in the diquafosol group and HA group, respectively, with borderline significant intergroup differences (p=0.046), while adverse drug reaction incidence rates were 12.2% (30 of 246 subjects) and 6.0% (15 of 251 subjects), respectively (p=0.019). Only mild adverse drug reactions (>2%) in the form of eye discharge, itching or irritation were observed. Diquafosol improved fluorescein staining score in a manner similar to HA, and significantly improved RB score compared with HA. NCT01101984. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Finite escape fraction for ultrahigh energy collisions around Kerr

    Indian Academy of Sciences (India)

    We investigate the issue of observability of high-energy collisions around Kerr naked singularity and show that results are in contrast with the Kerr black hole case. We had shown that it would be possible to have ultrahigh energy collisions between the particles close to the location = M around the Kerr naked singularity if ...

  7. Finite escape fraction for ultrahigh energy collisions around Kerr ...

    Indian Academy of Sciences (India)

    Abstract. We investigate the issue of observability of high-energy collisions around Kerr naked singularity and show that results are in contrast with the Kerr black hole case. We had shown that it would be possible to have ultrahigh energy collisions between the particles close to the location r = M around the Kerr naked ...

  8. Terapascal static pressure generation with ultrahigh yield strength nanodiamond.

    Science.gov (United States)

    Dubrovinskaia, Natalia; Dubrovinsky, Leonid; Solopova, Natalia A; Abakumov, Artem; Turner, Stuart; Hanfland, Michael; Bykova, Elena; Bykov, Maxim; Prescher, Clemens; Prakapenka, Vitali B; Petitgirard, Sylvain; Chuvashova, Irina; Gasharova, Biliana; Mathis, Yves-Laurent; Ershov, Petr; Snigireva, Irina; Snigirev, Anatoly

    2016-07-01

    Studies of materials' properties at high and ultrahigh pressures lead to discoveries of unique physical and chemical phenomena and a deeper understanding of matter. In high-pressure research, an achievable static pressure limit is imposed by the strength of available strong materials and design of high-pressure devices. Using a high-pressure and high-temperature technique, we synthesized optically transparent microballs of bulk nanocrystalline diamond, which were found to have an exceptional yield strength (~460 GPa at a confining pressure of ~70 GPa) due to the unique microstructure of bulk nanocrystalline diamond. We used the nanodiamond balls in a double-stage diamond anvil cell high-pressure device that allowed us to generate static pressures beyond 1 TPa, as demonstrated by synchrotron x-ray diffraction. Outstanding mechanical properties (strain-dependent elasticity, very high hardness, and unprecedented yield strength) make the nanodiamond balls a unique device for ultrahigh static pressure generation. Structurally isotropic, homogeneous, and made of a low-Z material, they are promising in the field of x-ray optical applications.

  9. Ophthalmic artery chemosurgery: A nursing perspective

    Directory of Open Access Journals (Sweden)

    Mary Elizabeth Davis

    2017-01-01

    Full Text Available Retinoblastoma (RB is the most common primary cancer to affect the eyes in children with approximately 350 cases/year in the United States and 8000 worldwide. Today, sadly, 50% of children with RB worldwide die from their disease. In our experience, utilization of ophthalmic artery chemosurgery (OAC has transformed the treatment plan for patients; with over 1500 procedures performed, our survival rate exceeds 98%. It is now our standard first-line therapy for RB. OAC is a surgical outpatient procedure which delivers concentrated doses of chemotherapy directly to the tumor without the toxicities of systemic chemotherapy. Our team approach and nursing management of these patients are the focus of this article. Nursing navigation and collaboration after OAC is vital and requires a combined effort by the nurses along with physicians, interventional radiologists, and the patient's families to ensure appropriate follow-up is established. Proper patient education throughout the process is crucial as is open and available communication for parents of patients with the nursing staff. The success in our treatment of this disease can be much accredited to the multidisciplinary team approach, with nursing playing an integral part in the support and management of these patients.

  10. Ultrahigh performance supercritical fluid chromatography of lipophilic compounds with application to synthetic and commercial biodiesel.

    Science.gov (United States)

    Ashraf-Khorassani, M; Yang, J; Rainville, P; Jones, M D; Fountain, K J; Isaac, G; Taylor, L T

    2015-03-01

    Ultrahigh performance supercritical fluid chromatography (UHPSFC) in combination with sub-2μm particles and either diode array ultraviolet (UV), evaporative light scattering, (ELSD), or mass spectrometric (MS) detection has been shown to be a valuable technique for the determination of acylglycerols in soybean, corn, sesame, and tobacco seed oils. Excellent resolution on an un-endcapped single C18 column (3.0mm×150mm) with a mobile phase gradient of acetonitrile and carbon dioxide in as little as 10min served greatly as an improvement on first generation packed column SFC instrumentation. Unlike high resolution gas chromatography and high performance liquid chromatography with mass spectrometric detection, UHPSFC/MS was determined to be a superior analytical tool for both separation and detection of mono-, di-, and tri-acylglycerols as well as free glycerol itself in biodiesel without derivatization. Baseline separation of residual tri-, di-, and mono-acylglycerols alongside glycerol at 0.05% (w/w) was easily obtained employing packed column SFC. The new analytical methodology was applied to both commercial B100 biodiesel (i.e. fatty acid methyl esters) derived from vegetable oil and to an "in-house" synthetic biodiesel (i.e. fatty acid ethyl esters) derived from tobacco seed oil and ethanol both before and after purification via column chromatography on bare silica. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. 76 FR 28045 - Determination That XIBROM (Bromfenac Ophthalmic Solution) 0.09% Was Not Withdrawn From Sale for...

    Science.gov (United States)

    2011-05-13

    ... marketing for reasons other than safety or effectiveness. ANDAs that refer to XIBROM (bromfenac ophthalmic... Safety or Effectiveness AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and... withdrawn from sale for reasons of safety or effectiveness. This determination will allow FDA to approve...

  12. Ocular pharmacokinetics comparison between 0.2% olopatadine and 0.77% olopatadine hydrochloride ophthalmic solutions administered to male New Zealand white rabbits.

    Science.gov (United States)

    Iyer, Ganesh R; Cason, Marita M; Womble, Scott W; Li, Guangming; Chastain, James E

    2015-05-01

    The primary objective of this study was to compare uptake and distribution of the commercially available formulation of 0.2% olopatadine and the newly developed 0.77% olopatadine hydrochloride ophthalmic solution formulation with improved solubility following a single (30 μL), bilateral topical ocular dose in male New Zealand white rabbits. Each animal received a single 30-μL topical ocular dose (0.2% olopatadine or 0.77% olopatadine hydrochloride ophthalmic solution) to the right (OD) eye followed by the left (OS) eye for a total dose of 60 μL. Olopatadine concentrations were measured in ocular tissues (cornea, bulbar, conjunctiva, choroid, iris-ciliary body, whole lens, retina), aqueous humor, and plasma at prespecified time points over 24 h using a qualified liquid chromatography coupled with mass spectrometry (LC-MS/MS) analytical method. Olopatadine was absorbed into the eye and reached maximal levels (Cmax) within 30 min (0.5 h) to 2 h (Tmax) in ocular tissues and plasma for both treatment groups, except for the lens in which the Tmax was 4 h in the 0.2% olopatadine group and 8 h in the 0.77% olopatadine hydrochloride group, respectively. Tissues associated with the site of dosing, that is, the conjunctiva and cornea, had the highest concentrations of olopatadine in both the 0.2% olopatadine (609 and 720 ng/g) and 0.77% olopatadine hydrochloride (3,000 and 2,230 ng/g) dose groups. The greatest differences between 0.2% olopatadine and 0.77% olopatadine hydrochloride were associated with the overall duration and level of ocular exposures. The newly developed 0.77% olopatadine hydrochloride ophthalmic solution formulation resulted in a higher and more prolonged olopatadine concentration in the target tissue, that is, conjunctiva compared to the commercial formulation of 0.2% olopatadine ophthalmic solution.

  13. A Monte-Carlo simulation of the equilibrium beam polarization in ultra-high energy electron (positron) storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Zhe, E-mail: zhe.duan@ihep.ac.cn [Key Laboratory of Particle Acceleration Physics and Technology, Institute of High Energy Physics, Chinese Academy of Sciences, 100049 Beijing (China); University of Chinese Academy of Sciences, 100049 Beijing (China); Bai, Mei [Forschungszentrum Jülich GmbH, 52428 Jülich (Germany); Barber, Desmond P. [Deutsches Elektronen-Synchrotron, DESY, 22607 Hamburg (Germany); Qin, Qing [Key Laboratory of Particle Acceleration Physics and Technology, Institute of High Energy Physics, Chinese Academy of Sciences, 100049 Beijing (China)

    2015-09-01

    With the recently emerging global interest in building a next generation of circular electron–positron colliders to study the properties of the Higgs boson, and other important topics in particle physics at ultra-high beam energies, it is also important to pursue the possibility of implementing polarized beams at this energy scale. It is therefore necessary to set up simulation tools to evaluate the beam polarization at these ultra-high beam energies. In this paper, a Monte-Carlo simulation of the equilibrium beam polarization based on the Polymorphic Tracking Code (PTC) (Schmidt et al., 2002 [1]) is described. The simulations are for a model storage ring with parameters similar to those of proposed circular colliders in this energy range, and they are compared with the suggestion (Derbenev et al., 1979 [2]) that there are different regimes for the spin dynamics underlying the polarization of a beam in the presence of synchrotron radiation at ultra-high beam energies. In particular, it has been suggested that the so-called “correlated” crossing of spin resonances during synchrotron oscillations at current energies evolves into “uncorrelated” crossing of spin resonances at ultra-high energies.

  14. A Monte-Carlo simulation of the equilibrium beam polarization in ultra-high energy electron (positron) storage rings

    International Nuclear Information System (INIS)

    Duan, Zhe; Bai, Mei; Barber, Desmond P.; Qin, Qing

    2015-04-01

    With the recently emerging global interest in building a next generation of circular electron-positron colliders to study the properties of the Higgs boson, and other important topics in particle physics at ultra-high beam energies, it is also important to pursue the possibility of implementing polarized beams at this energy scale. It is therefore necessary to set up simulation tools to evaluate the beam polarization at these ultra-high beam energies. In this paper, a Monte-Carlo simulation of the equilibrium beam polarization based on the Polymorphic Tracking Code(PTC) (Schmidt et al., 2002) is described. The simulations are for a model storage ring with parameters similar to those of proposed circular colliders in this energy range, and they are compared with the suggestion (Derbenev et al., 1978) that there are different regimes for the spin dynamics underlying the polarization of a beam in the presence of synchrotron radiation at ultra-high beam energies. In particular, it has been suggested that the so-called ''correlated'' crossing of spin resonances during synchrotron oscillations at current energies, evolves into ''uncorrelated'' crossing of spin resonances at ultra-high energies.

  15. Proton-proton elastic scattering at ultrahigh energies

    International Nuclear Information System (INIS)

    Saleem, M.; Shaukat, M.A.; Fazal-e-Aleem

    1981-01-01

    Recent experimental results on proton-proton elastic scattering at high energies are discussed in the context of the comments by Chou and Yang. There does not appear to be any tendency that the experimental results would agree with the predictions of the geometrical model even at ultrahigh energies. The angular distribution structure as described by using the dipole pomeron is consistent with the experimental data at presently available high energies and predicts results quite different from the geometrical model. (author)

  16. Ultra-high efficiency, fast graphene micro-heater on silicon

    DEFF Research Database (Denmark)

    Yan, Siqi; Zhu, Xiaolong; Frandsen, Lars Hagedorn

    2017-01-01

    We demonstrate an ultra-high efficiency and fast graphene microheater on silicon photonic crystal waveguide. By taking advantage of slow-light effect, a tuning efficiency of 1.07 nm/mW and power consumption per free spectral range of 3.99 mW. A fast rise and decay times (10% to 90%) of only 750 ns...

  17. Identification and super-resolution imaging of ligand-activated receptor dimers in live cells

    Science.gov (United States)

    Winckler, Pascale; Lartigue, Lydia; Giannone, Gregory; de Giorgi, Francesca; Ichas, François; Sibarita, Jean-Baptiste; Lounis, Brahim; Cognet, Laurent

    2013-08-01

    Molecular interactions are key to many chemical and biological processes like protein function. In many signaling processes they occur in sub-cellular areas displaying nanoscale organizations and involving molecular assemblies. The nanometric dimensions and the dynamic nature of the interactions make their investigations complex in live cells. While super-resolution fluorescence microscopies offer live-cell molecular imaging with sub-wavelength resolutions, they lack specificity for distinguishing interacting molecule populations. Here we combine super-resolution microscopy and single-molecule Förster Resonance Energy Transfer (FRET) to identify dimers of receptors induced by ligand binding and provide super-resolved images of their membrane distribution in live cells. By developing a two-color universal-Point-Accumulation-In-the-Nanoscale-Topography (uPAINT) method, dimers of epidermal growth factor receptors (EGFR) activated by EGF are studied at ultra-high densities, revealing preferential cell-edge sub-localization. This methodology which is specifically devoted to the study of molecules in interaction, may find other applications in biological systems where understanding of molecular organization is crucial.

  18. Innovative Ultra-High Efficiency Cryogenic Actuators for Rocket Test Facilities, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The SBIR Phase I project will develop advanced ultra-high efficiency cryogenic actuators for NASA cryogenic fluid transfer application. The actuator will have low...

  19. Systematic profiling and comparison of the lipidomes from Panax ginseng, P. quinquefolius, and P. notoginseng by ultrahigh performance supercritical fluid chromatography/high-resolution mass spectrometry and ion mobility-derived collision cross section measurement.

    Science.gov (United States)

    Shi, Xiaojian; Yang, Wenzhi; Qiu, Shi; Hou, Jinjun; Wu, Wanying; Guo, Dean

    2018-05-04

    Lipidomics currently is still confronted with challenges from chromatographic separation and lipids identification. Here we report a lipidomics platform by integrating ultrahigh performance supercritical fluid chromatography/quadrupole time-of-flight mass spectrometry (UHPSFC/QTOF-MS) and collision cross section (CCS) measurement using ion mobility spectroscopy/time-of-flight mass spectrometry (IMS/QTOF-MS), aiming to enhance the profiling performance and identification reliability of lipids. The lipidomes extracted from three congeneric Panax species (P. ginseng, P. quinquefolius, and P. notoginseng) by methyl tert-butyl ether are comprehensively profiled and compared by use of this platform. A potent UHPSFC/QTOF-MS approach was developed on a 1.7-μm particles packed Torus 2-PIC column using CH 3 OH (in CO 2 ) as a modifier and CH 3 OH/0.2 mM ammonium acetate as the makeup liquid, enabling well resolution of six lipid subclasses by both positive and negative MS E modes. In contrast to the reversed-phase chromatography, "normal-phase" like elution order and better resolution of polar lipids and some lipid isomers were achieved by UHPSFC separation. Pattern recognition chemometric analysis of 60 batches of Ginseng samples ultimately unveiled 24 lipid markers, of which triacylglycerols were the most important. Aside from the automated MS database searching against HMDB and LIPID MAPS, the application of CCS retrieval or CCS prediction improved lipid identification by reducing the possible hits. In conclusion, this integral platform can significantly improve the chromatographic separation and the reliability of lipids identification in lipidomics studies. It is the first report that systematically compares the lipidomic difference of three reputable Panax species, providing useful information for their quality control in addition to ginsenoside analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Ophthalmic Vascular Events after Primary Unilateral Intra-arterial Chemotherapy for Retinoblastoma in Early and Recent Eras.

    Science.gov (United States)

    Dalvin, Lauren A; Ancona-Lezama, David; Lucio-Alvarez, J Antonio; Masoomian, Babak; Jabbour, Pascal; Shields, Carol L

    2018-06-16

    To assess risk factors for ophthalmic vascular events after intra-arterial chemotherapy (IAC) for retinoblastoma. Retrospective cohort study. Patients who received unilateral IAC as primary treatment for retinoblastoma from January 1, 2009, to November 30, 2017, at a single center. Records were reviewed for patient demographics, tumor features, IAC parameters, and treatment-related vascular events in the early IAC era (2009-2011) compared with the recent era (2012-2017) using the t test and Fisher exact test. Change in event rates over time was assessed using Poisson regression analysis, with Spearman's rho used to test correlation. Rate of IAC-induced ophthalmic vascular events. There were 243 chemotherapy infusions in 76 eyes of 76 patients, divided into early (22 eyes, 57 infusions) and recent (54 eyes, 186 infusions) eras. Intra-arterial chemotherapy consisted of melphalan (243 infusions), topotecan (124 infusions), and carboplatin (9 infusions). A comparison (early vs. recent era) revealed fewer mean number of infusions (2.6 vs. 3.4, P = 0.02) with similar mean patient age and presenting tumor features. Event rates decreased over time (P early era vs. recent era) in the recent era (59% vs. 9% per eye, 23% vs. 3% per infusion, P age (P = 0.75), tumor diameter (P = 0.32), tumor thickness (P = 0.59), or cumulative dosage of melphalan (P = 0.13) or topotecan (P = 0.59). There were no IAC-induced vascular events in 72 infusions of 21 consecutively treated eyes in 2016 to 2017. Ophthalmic vascular events after IAC have decreased from the early era (2009-2011) through the current era (2012-2017) at this center. Experience performing this highly specialized procedure could be an important factor predicting IAC-related vascular events. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.