WorldWideScience

Sample records for ucla imaging study

  1. PACS module image communication at UCLA

    International Nuclear Information System (INIS)

    Stewart, B.K.; Taira, R.K.; Cho, P.S.; Mankovich, N.J.

    1987-01-01

    The advent of the ACR-NEMA digital and communication standard for PACS implementation between imaging, storage and display devices may simplify the networking problems inherent to PACS in the future. However, since the ACR-NEMA interface has not been implemented in manufactured products, the components of a PACS at the present time use various network interface designs, requiring substantial effort in the area of hardware and software integration. Many communication systems are used for the PACS implementation in Pediatric Radiology at UCLA, including baseband, broadband, as well as various parallel-line interface protocols, e.g. GP-IB. A VAX 11/750 minicomputer serves as the host computer for the UCLA Pediatric Radiology PACS system. Communication between the many peripherals take place through the host computer, which acts as the central node. Several communication links have been established, primarily: host computer to other local computers, image processors, various peripherals (digitizers, storage media, etc.) and, of course, to the 512, 1024 and 2048 viewing stations

  2. UCLA Translational Biomarker Development Program (UTBD)

    Energy Technology Data Exchange (ETDEWEB)

    Czernin, Johannes [Univ. of California, Los Angeles, CA (United States)

    2014-09-01

    The proposed UTBD program integrates the sciences of diagnostic nuclear medicine and (radio)chemistry with tumor biology and drug development. UTBD aims to translate new PET biomarkers for personalized medicine and to provide examples for the use of PET to determine pharmacokinetic (PK) and pharmacodynamic (PD) drug properties. The program builds on an existing partnership between the Ahmanson Translational Imaging Division (ATID) and the Crump Institute of Molecular Imaging (CIMI), the UCLA Department of Chemistry and the Division of Surgical Oncology. ATID provides the nuclear medicine training program, clinical and preclinical PET/CT scanners, biochemistry and biology labs for probe and drug development, radiochemistry labs, and two cyclotrons. CIMI provides DOE and NIH-funded training programs for radio-synthesis (START) and molecular imaging (SOMI). Other participating entities at UCLA are the Department of Chemistry and Biochemistry and the Division of Surgical Oncology. The first UTBD project focuses on deoxycytidine kinase, a rate-limiting enzyme in nucleotide metabolism, which is expressed in many cancers. Deoxycytidine kinase (dCK) positive tumors can be targeted uniquely by two distinct therapies: 1) nucleoside analog prodrugs such as gemcitabine (GEM) are activated by dCK to cytotoxic antimetabolites; 2) recently developed small molecule dCK inhibitors kill tumor cells by starving them of nucleotides required for DNA replication and repair. Since dCK-specific PET probes are now available, PET imaging of tumor dCK activity could improve the use of two different classes of drugs in a wide variety of cancers.

  3. EVALUASI CSE-UCLA PADA STUDI PROSES PEMBELAJARAN MATEMATIKA

    Directory of Open Access Journals (Sweden)

    Siska Andriani

    2015-12-01

    Full Text Available tandar proses merupakan salah satu standar nasional yang mengatur perencanaan, pelaksanaan, penilaian, dan pengawasan proses pembelajaran. Pelaksanaan standar proses yang terjadi di lapangan belum terlihat keterlaksanaannya. Tujuan penelitian ini yaitu memperoleh deskripsi keterlaksanaan standar proses pada proses pembelajaran matematika menggunakan analisis CSE-UCLA di SMP Negeri Satu Atap Lerep. Penelitian ini merupakan penelitian kualitatif dengan pendekatan evaluatif. Sumber data utama adalah guru matematika. Teknik pengumpulan data menggunakan wawancara, observasi, dan dokumentasi. Keabsahan data yang digunakan dalam penelitian ini menggunakan uji credibility (triangulasi dan kecukupan bahan referensi, uji transferability, dan uji dependability.  Hasil penelitian menunjukkan bahwa proses pembelajaran matematika di SMP Negeri Satu Atap Lerep sudah mengikuti standar proses. Implementasi standar proses dengan analisis CSE-UCLA menunjukkan bahwa standar proses dilaksanakan melalui tahap  perencanaan, pengembangan, implementasi, hasil dan dampak. Dampak yang muncul pembelajaran yang terjadi tidak maksimal. Selain itu, banyak faktor yang mempengaruhi implementasi standar proses pada pembelajaran matematika di SMP Negeri Satu Atap Lerep. Faktor-faktor tersebut berupa faktor pendukung dan faktor penghambat.

  4. Reliability and validity of the Danish version of the UCLA Loneliness Scale

    DEFF Research Database (Denmark)

    Lasgaard, Mathias

    2007-01-01

    The objective of this study was to examine the psychometric properties of a Danish version of the UCLA Loneliness Scale (UCLA). The 20-item scale was completed along with other measures in a national youth probability sample of 379 8th grade students aged 13-17. The scale showed high internal con....... The results, highly comparable to the original version of the scale, indicate that the Danish version of UCLA is a reliable and valid measure of loneliness....... consistency, and correlations between UCLA and measures of emotional loneliness, social loneliness, self-esteem, depression, extraversion, and neuroticism supported the convergent and discriminant validity of the scale. Exploratory factor analysis supported a unidimensional structure of the measure...

  5. A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

    Science.gov (United States)

    Park, Ji-Man; Lee, Jai-Bong; Heo, Seong-Joo

    2014-01-01

    PURPOSE The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ±0.1 µm at 50 points. RESULTS Initial detorque values of milled abutment were significantly higher than those of cast abutment (P.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (Pabutment group and the cast abutment group after cyclic loading. CONCLUSION In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment. PMID:24605206

  6. UCLA accelerator research ampersand development. Progress report

    International Nuclear Information System (INIS)

    1997-01-01

    This report discusses work on advanced accelerators and beam dynamics at ANL, BNL, SLAC, UCLA and Pulse Sciences Incorporated. Discussed in this report are the following concepts: Wakefield acceleration studies; plasma lens research; high gradient rf cavities and beam dynamics studies at the Brookhaven accelerator test facility; rf pulse compression development; and buncher systems for high gradient accelerator and relativistic klystron applications

  7. Experimental and theoretical high energy physics research. [UCLA

    Energy Technology Data Exchange (ETDEWEB)

    Buchanan, Charles D.; Cline, David B.; Byers, N.; Ferrara, S.; Peccei, R.; Hauser, Jay; Muller, Thomas; Atac, Muzaffer; Slater, William; Cousins, Robert; Arisaka, Katsushi

    1992-01-01

    Progress in the various components of the UCLA High-Energy Physics Research program is summarized, including some representative figures and lists of resulting presentations and published papers. Principal efforts were directed at the following: (I) UCLA hadronization model, PEP4/9 e{sup +}e{sup {minus}} analysis, {bar P} decay; (II) ICARUS and astroparticle physics (physics goals, technical progress on electronics, data acquisition, and detector performance, long baseline neutrino beam from CERN to the Gran Sasso and ICARUS, future ICARUS program, and WIMP experiment with xenon), B physics with hadron beams and colliders, high-energy collider physics, and the {phi} factory project; (III) theoretical high-energy physics; (IV) H dibaryon search, search for K{sub L}{sup 0} {yields} {pi}{sup 0}{gamma}{gamma} and {pi}{sup 0}{nu}{bar {nu}}, and detector design and construction for the FNAL-KTeV project; (V) UCLA participation in the experiment CDF at Fermilab; and (VI) VLPC/scintillating fiber R D.

  8. Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant.

    Science.gov (United States)

    Yoon, Ki-Joon; Park, Young-Bum; Choi, Hyunmin; Cho, Youngsung; Lee, Jae-Hoon; Lee, Keun-Woo

    2016-12-01

    The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of 1.0 × 10 6 cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups ( P >.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

  9. Laser wakefields at UCLA and LLNL

    International Nuclear Information System (INIS)

    Mori, W.B.; Clayton, C.E.; Joshi, C.; Dawson, J.M.; Decker, C.B.; Marsh, K.; Katsouleas, T.; Darrow, C.B.; Wilks, S.C.

    1991-01-01

    The authors report on recent progress at UCLA and LLNL on the nonlinear laser wakefield scheme. They find advantages to operating in the limit where the laser pulse is narrow enough to expel all the plasma electrons from the focal region. A description of the experimental program for the new short pulse 10 TW laser facility at LLNL is also presented

  10. SAPS simulation with GITM/UCLA-RCM coupled model

    Science.gov (United States)

    Lu, Y.; Deng, Y.; Guo, J.; Zhang, D.; Wang, C. P.; Sheng, C.

    2017-12-01

    Abstract: SAPS simulation with GITM/UCLA-RCM coupled model Author: Yang Lu, Yue Deng, Jiapeng Guo, Donghe Zhang, Chih-Ping Wang, Cheng Sheng Ion velocity in the Sub Aurora region observed by Satellites in storm time often shows a significant westward component. The high speed westward stream is distinguished with convection pattern. These kind of events are called Sub Aurora Polarization Stream (SAPS). In March 17th 2013 storm, DMSP F18 satellite observed several SAPS cases when crossing Sub Aurora region. In this study, Global Ionosphere Thermosphere Model (GITM) has been coupled to UCLA-RCM model to simulate the impact of SAPS during March 2013 event on the ionosphere/thermosphere. The particle precipitation and electric field from RCM has been used to drive GITM. The conductance calculated from GITM has feedback to RCM to make the coupling to be self-consistent. The comparison of GITM simulations with different SAPS specifications will be conducted. The neutral wind from simulation will be compared with GOCE satellite. The comparison between runs with SAPS and without SAPS will separate the effect of SAPS from others and illustrate the impact on the TIDS/TADS propagating to both poleward and equatorward directions.

  11. REFORMA/UCLA Mentor Program: A Mentoring Manual.

    Science.gov (United States)

    Tauler, Sandra

    Although mentoring dates back to Greek mythology, the concept continues to thrive in today's society. Mentoring is a strategy that successful people have known about for centuries. The REFORMA/UCLA Mentor Program has made use of this strategy since its inception in November 1985 at the Graduate School of Library and Information Science at the…

  12. MHD PbLi experiments in MaPLE loop at UCLA

    International Nuclear Information System (INIS)

    Courtessole, C.; Smolentsev, S.; Sketchley, T.; Abdou, M.

    2016-01-01

    Highlights: • The paper overviews the MaPLE facility at UCLA: one-of-a-few PbLi MHD loop in the world. • We present the progress achieved in development and testing of high-temperature PbLi flow diagnostics. • The most important MHD experiments carried out since the first loop operation in 2011 are summarized. - Abstract: Experiments on magnetohydrodynamic (MHD) flows are critical to understanding complex flow phenomena in ducts of liquid metal blankets, in particular those that utilize eutectic alloy lead–lithium as breeder/coolant, such as self-cooled, dual-coolant and helium-cooled lead–lithium blanket concepts. The primary goal of MHD experiments at UCLA using the liquid metal flow facility called MaPLE (Magnetohydrodynamic PbLi Experiment) is to address important MHD effects, heat transfer and flow materials interactions in blanket-relevant conditions. The paper overviews the one-of-a-kind MaPLE loop at UCLA and presents recent experimental activities, including the development and testing of high-temperature PbLi flow diagnostics and experiments that have been performed since the first loop operation in 2011. We also discuss MaPLE upgrades, which need to be done to substantially expand the experimental capabilities towards a new class of MHD flow phenomena that includes buoyancy effects.

  13. MHD PbLi experiments in MaPLE loop at UCLA

    Energy Technology Data Exchange (ETDEWEB)

    Courtessole, C., E-mail: cyril@fusion.ucla.edu; Smolentsev, S.; Sketchley, T.; Abdou, M.

    2016-11-01

    Highlights: • The paper overviews the MaPLE facility at UCLA: one-of-a-few PbLi MHD loop in the world. • We present the progress achieved in development and testing of high-temperature PbLi flow diagnostics. • The most important MHD experiments carried out since the first loop operation in 2011 are summarized. - Abstract: Experiments on magnetohydrodynamic (MHD) flows are critical to understanding complex flow phenomena in ducts of liquid metal blankets, in particular those that utilize eutectic alloy lead–lithium as breeder/coolant, such as self-cooled, dual-coolant and helium-cooled lead–lithium blanket concepts. The primary goal of MHD experiments at UCLA using the liquid metal flow facility called MaPLE (Magnetohydrodynamic PbLi Experiment) is to address important MHD effects, heat transfer and flow materials interactions in blanket-relevant conditions. The paper overviews the one-of-a-kind MaPLE loop at UCLA and presents recent experimental activities, including the development and testing of high-temperature PbLi flow diagnostics and experiments that have been performed since the first loop operation in 2011. We also discuss MaPLE upgrades, which need to be done to substantially expand the experimental capabilities towards a new class of MHD flow phenomena that includes buoyancy effects.

  14. Material analyses of foam-based SiC FCI after dynamic testing in PbLi in MaPLE loop at UCLA

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Maria, E-mail: maria.gonzalez@ciemat.es [LNF-CIEMAT, Avda Complutense, 40, 28040 Madrid (Spain); Rapisarda, David; Ibarra, Angel [LNF-CIEMAT, Avda Complutense, 40, 28040 Madrid (Spain); Courtessole, Cyril; Smolentsev, Sergey; Abdou, Mohamed [Fusion Science and Technology Center, UCLA (United States)

    2016-11-01

    Highlights: • Samples from foam-based SiC FCI were analyzed by looking at their SEM microstructure and elemental composition. • After finishing dynamic experiments in the flowing hot PbLi, the liquid metal ingress has been confirmed due to infiltration through local defects in the protective inner CVD layer. • No direct evidences of corrosion/erosion were observed; these defects could be related to the manufacturing process. - Abstract: Foam-based SiC flow channel inserts (FCIs) developed and manufactured by Ultramet, USA are currently under testing in the flowing hot lead-lithium (PbLi) alloy in the MaPLE loop at UCLA to address chemical/physical compatibility and to access the MHD pressure drop reduction. UCLA has finished the first experimental series, where a single uninterrupted long-term (∼6500 h) test was performed on a 30-cm FCI segment in a magnetic field up to 1.8 T at the temperature of 300 °C and maximum flow velocities of ∼ 15 cm/s. After finishing the experiments, the FCI sample was extracted from the host stainless steel duct and cut into slices. Few of them have been analyzed at CIEMAT as a part of the joint collaborative effort on the development of the DCLL blanket concept in the EU and the US. The initial inspection of the slices using optical microscopic analysis at UCLA showed significant PbLi ingress into the bulk FCI material that resulted in degradation of insulating properties of the FCI. Current material analyses at CIEMAT are based on advanced techniques, including characterization of FCI samples by FESEM to study PbLi ingress, imaging of cross sections, composition analysis by EDX and crack inspection. These analyses suggest that the ingress was caused by local defects in the protective inner CVD layer that might be originally present in the FCI or occurred during testing.

  15. LGBT and Information Studies: The Library and Archive OUTreach Symposium at UCLA; and In the Footsteps of Barbara Gittings: An Appreciation

    OpenAIRE

    Keilty, Patrick

    2007-01-01

    On November 17, 2006 the InterActions editorial team attended the Library and Archives OUTreach symposium at UCLA. This galvanizing event brought together academics, practitioners, and activists from the information studies field to discuss the importance of increasing visibility around lesbian, gay, bisexual, and transgendered (LGBT) issues as they pertain to libraries and information seeking. Given the tremendous energy generated by these proceedings, we asked Patrick Keilty, a doctoral st...

  16. The UCLA Young Autism Project: A Reply to Gresham and Macmillan.

    Science.gov (United States)

    Smith, Tristam; Lovass, O. Ivar

    1997-01-01

    Responds to "Autistic Recovery? An Analysis and Critique of the Empirical Evidence on the Early Intervention Project" (Gresham and MacMillan), which criticizes research showing the effectiveness of the UCLA Youth Autism Project program for children with autism. The article's misunderstandings are discussed and the program is explained. (CR)

  17. UCLA Particle Physics Research Group annual progress report

    International Nuclear Information System (INIS)

    Nefkens, B.M.K.

    1981-08-01

    The objectives, basic research programs, recent results and continuing activities of the UCLA Particle Physics Research Group are presented. The objectives of the research are to discover, to formulate, and to elucidate the physics laws that govern the elementary constituents of matter and to determine basic properties of particles. A synopsis of research carried out last year is given. The main body of this report is the account of the techniques used in our investigations, the results obtained, and the plans for continuing and new research

  18. UCLA1 aptamer inhibition of human immunodeficiency virus type 1 subtype C primary isolates in macrophages and selection of resistance

    CSIR Research Space (South Africa)

    Mufhandu, Hazel T

    2016-09-01

    Full Text Available isolates in monocyte-derived macrophages (MDMs). Of 4 macrophage-tropic isolates tested, 3 were inhibited by UCLA1 in the low nanomolar range (IC80 <29 nM). One isolate that showed reduced susceptibility (<50 nM) to UCLA1 contained mutations in the a5 helix...

  19. Occupational Analysis: Hospital Radiologic Technologist. The UCLA Allied Health Professions Project.

    Science.gov (United States)

    Reeder, Glenn D.; And Others

    In an effort to meet the growing demand for skilled radiologic technologists and other supportive personnel educated through the associate degree level, a national survey was conducted as part of the UCLA Allied Health Professions Project to determine the tasks performed by personnel in the field and lay the groundwork for development of…

  20. Evidências de validade da Escala Brasileira de Solidão UCLA

    Directory of Open Access Journals (Sweden)

    Sabrina Martins Barroso

    2016-03-01

    Full Text Available RESUMO Objetivo Este trabalho investigou as evidências de validade da Escala de Solidão UCLA para aplicação na população brasileira. Métodos Foram seguidas as fases: (1 autorização do autor e do Comitê de Ética; (2 tradução e retrotradução; (3 adaptação semântica; (4 validação. Utilizou-se para análise dos dados análise descritiva, fatorial exploratória, alpha de Cronbach, Kappa, teste de esfericidade de Barlett, teste Kaiser-Meyer-Olkin e correlação de Pearson. Para a adaptação, a escala foi submetida a especialistas e a um grupo focal com 8 participantes para adaptação semântica e a um estudo piloto com 126 participantes para adaptação transcultural. Da validação, participaram 818 pessoas, entre 20 e 87 anos, que responderam a duas versões da UCLA, ao Questionário de Saúde do Paciente, à Escala de Percepção de Suporte Social e a um questionário elaborado pelos autores. Resultados A escala mostrou dois fatores, que explicaram 56% da variância e alpha de 0,94. Conclusões A Escala de Solidão UCLA-BR indicou evidências de validade de construto e discriminante, além de boa fidedignidade, podendo ser utilizada para avaliação da solidão na população brasileira.

  1. UCLA's outreach program of science education in the Los Angeles schools.

    Science.gov (United States)

    Palacio-Cayetano, J; Kanowith-Klein, S; Stevens, R

    1999-04-01

    The UCLA School of Medicine's Interactive Multi-media Exercises (IMMEX) Project began its outreach into pre-college education in the Los Angeles area in 1993. The project provides a model in which software and technology are effectively intertwined with teaching, learning, and assessment (of both students' and teachers' performances) in the classroom. The project has evolved into a special collaboration between the medical school and Los Angeles teachers. UCLA faculty and staff work with science teachers and administrators from elementary, middle, and high schools. The program benefits ethnically and racially diverse groups of students in schools ranging from the inner city to the suburbs. The project's primary goal is to use technology to increase students' achievement and interest in science, including medicine, and thus move more students into the medical school pipeline. Evaluations from outside project evaluators (West Ed) as well as from teachers and IMMEX staff show that the project has already had a significant effect on teachers' professional development, classroom practice, and students' achievement in the Los Angeles area.

  2. Analysis of material removed from UCLA tokamaks Microtor and Macrotor

    International Nuclear Information System (INIS)

    Baer, D.R.; Thomas, M.T.; Taylor, R.J.

    1979-02-01

    This paper reports a first effort to examine the surface of the UCLA tokamaks, Microtor and Macrotor, by analyzing samples that have been exposed to plasma discharge and cleaning for long periods. The samples were sent to the Surface Science Section at the Pacific Northwest Laboratory (PNL). There, Auger electron spectrometry and sputter profile techniques were used to examine the samples, which had been handled in atmospheric conditions after being removed from the tokamak

  3. Emittance studies of the BNL/SLAC/UCLA 1.6 cell photocathode rf gun

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Wang, X.J.

    1997-01-01

    The symmetrized 1.6 cell S-band photocathode gun developed by the BNL/SLAC/UCLA collaboration is in operation at the Brookhaven Accelerator Test Facility (ATF). A novel emittance compensation solenoid magnet has also been designed, built and is in operation at the ATF. These two subsystems form an emittance compensated photoinjector used for beam dynamics, advanced acceleration and free electron laser experiments at the ATF. The highest acceleration field achieved on the copper cathode is 150 MV/m, and the guns normal operating field is 130 MV/m. The maximum rf pulse length is 3 micros. The transverse emittance of the photoelectron beam were measured for various injection parameters. The 1 nC emittance results are presented along with electron bunch length measurements that indicated that at above the 400 pC, space charge bunch lengthening is occurring. The thermal emittance, ε o , of the copper cathode has been measured

  4. Microscopic evaluation of implant platform adaptation with UCLA-type abutments: in vitro study

    Directory of Open Access Journals (Sweden)

    Vinícius Anéas RODRIGUES

    Full Text Available Abstract Introduction The fit between abutment and implant is crucial to determine the longevity of implant-supported prostheses and the maintenance of peri-implant bones. Objective To evaluate the vertical misfit between different abutments in order to provide information to assist abutment selection. Material and method UCLA components (N=40 with anti-rotational system were divided as follows: components usinated in titanium (n=10 and plastic components cast proportionally in titanium (n=10, nickel-chromium-titanium-molybdenum (n=10 and nickel-chromium (n=10 alloys. All components were submitted to stereomicroscope analysis and were randomly selected for characterization by SEM. Result Data were analyzed using mean and standard deviation and subjected to ANOVA-one way, where the groups proved to statistically different (p=<0.05, followed by Tukey’s test. Conclusion The selection of material influences the value of vertical misfit. The group machined in Ti showed the lowest value while the group cast in Ni Cr showed the highest value of vertical misfit.

  5. Initial draft of CSE-UCLA evaluation model based on weighted product in order to optimize digital library services in computer college in Bali

    Science.gov (United States)

    Divayana, D. G. H.; Adiarta, A.; Abadi, I. B. G. S.

    2018-01-01

    The aim of this research was to create initial design of CSE-UCLA evaluation model modified with Weighted Product in evaluating digital library service at Computer College in Bali. The method used in this research was developmental research method and developed by Borg and Gall model design. The results obtained from the research that conducted earlier this month was a rough sketch of Weighted Product based CSE-UCLA evaluation model that the design had been able to provide a general overview of the stages of weighted product based CSE-UCLA evaluation model used in order to optimize the digital library services at the Computer Colleges in Bali.

  6. UCLA Particle Physics Research Group annual progress report

    International Nuclear Information System (INIS)

    Nefkens, B.M.K.

    1983-11-01

    The objectives, basic research programs, recent results, and continuing activities of the UCLA Particle Physics Research Group are presented. The objectives of the research are to discover, to formulate, and to elucidate the physics laws that govern the elementary constituents of matter and to determine basic properties of particles. The research carried out by the Group last year may be divided into three separate programs: (1) baryon spectroscopy, (2) investigations of charge symmetry and isospin invariance, and (3) tests of time reversal invariance. The main body of this report is the account of the techniques used in our investigations, the results obtained, and the plans for continuing and new research. An update of the group bibliography is given at the end

  7. Recent reflectometry results from the UCLA plasma diagnostics group

    International Nuclear Information System (INIS)

    Gilmore, M.; Doyle, E.J.; Kubota, S.; Nguyen, X.V.; Peebles, W.A.; Rhodes, T.L.; Zeng, L.

    2001-01-01

    The UCLA Plasma Diagnostics Group has an active ongoing reflectometry program. The program is threefold, including 1) profile and 2) fluctuation measurements on fusion devices (DIII-D, NSTX, and others), and 3) basic reflectometry studies in linear and laboratory plasmas that seek to develop new measurement capabilities and increase the physics understanding of reflectometry. Recent results on the DIII-D tokamak include progress toward the implementation of FM reflectometry as a standard density profile diagnostic, and correlation length measurements in QDB discharges that indicate a very different scaling than normally observed in L-mode plasmas. The first reflectometry measurements in a spherical torus (ST) have also been obtained on NSTX. Profiles in NSTX show good agreement with those of Thomson scattering. Finally, in a linear device, a local magnetic field strength measurement based on O-X correlation reflectometry has been demonstrated to proof of principle level, and correlation lengths measured by reflectometry are in good agreement with probes. (author)

  8. The UCLA/SLAC Ultra-High Gradient Cerenkov Wakefield Accelerator Experiment

    CERN Document Server

    Thompson, Matthew C; Hogan, Mark; Ischebeck, Rasmus; Muggli, Patric; Rosenzweig, James E; Scott, A; Siemann, Robert; Travish, Gil; Walz, Dieter; Yoder, Rodney

    2005-01-01

    An experiment is planned to study the performance of dielectric Cerenkov wakefield accelerating structures at extremely high gradients in the GV/m range. This new UCLA/SLAC collaboration will take advantage of the unique SLAC FFTB electron beam and its demonstrated ultra-short pulse lengths and high currents (e.g., sz = 20 μm at Q = 3 nC). The electron beam will be focused down and sent through varying lengths of fused silica capillary tubing with two different sizes: ID = 200 μm / OD = 325 μm and ID = 100 μm / OD = 325 μm. The pulse length of the electron beam will be varied in order to alter the accelerating gradient and probe the breakdown threshold of the dielectric structures. In addition to breakdown studies, we plan to collect and measure coherent Cerenkov radiation emitted from the capillary tube to gain information about the strength of the accelerating fields. Status and progress on the experiment are reported.

  9. 77 FR 25739 - Notice of Inventory Completion: Fowler Museum at UCLA, Los Angeles, CA

    Science.gov (United States)

    2012-05-01

    ... objects are 1 awl, 1 bone tool, 2 obsidian biface fragments, 9 bags of obsidian debitage, 4 stone metate fragments, 4 bags of animal bone, 1 obsidian hydration sample, and 5 bags of organic flotation residue. The... artifacts and obsidian hydration dating. The Fowler Museum at UCLA has determined the human remains and...

  10. Development and Testing of UCLA's Electron Losses and Fields Investigation (ELFIN) Instrument Payload

    Science.gov (United States)

    Wilkins, C.; Bingley, L.; Angelopoulos, V.; Caron, R.; Cruce, P. R.; Chung, M.; Rowe, K.; Runov, A.; Liu, J.; Tsai, E.

    2017-12-01

    UCLA's Electron Losses and Fields Investigation (ELFIN) is a 3U+ CubeSat mission designed to study relativistic particle precipitation in Earth's polar regions from Low Earth Orbit. Upon its 2018 launch, ELFIN will aim to address an important open question in Space Physics: Are Electromagnetic Ion-Cyclotron (EMIC) waves the dominant source of pitch-angle scattering of high-energy radiation belt charged particles into Earth's atmosphere during storms and substorms? Previous studies have indicated these scattering events occur frequently during storms and substorms, and ELFIN will be the first mission to study this process in-situ.Paramount to ELFIN's success is its instrument suite consisting of an Energetic Particle Detector (EPD) and a Fluxgate Magnetometer (FGM). The EPD is comprised of two collimated solid-state detector stacks which will measure the incident flux of energetic electrons from 50 keV to 4 MeV and ions from 50 keV to 300 keV. The FGM is a 3-axis magnetic field sensor which will capture the local magnetic field and its variations at frequencies up to 5 Hz. The ELFIN spacecraft spins perpendicular to the geomagnetic field to provide 16 pitch-angle particle data sectors per revolution. Together these factors provide the capability to address the nature of radiation belt particle precipitation by pitch-angle scattering during storms and substorms.ELFIN's instrument development has progressed into the late Engineering Model (EM) phase and will soon enter Flight Model (FM) development. The instrument suite is currently being tested and calibrated at UCLA using a variety of methods including the use of radioactive sources and applied magnetics to simulate orbit conditions during spin sectoring. We present the methods and test results from instrument calibration and performance validation.

  11. Vision screening of abused and neglected children by the UCLA Mobile Eye Clinic.

    Science.gov (United States)

    Yoo, R; Logani, S; Mahat, M; Wheeler, N C; Lee, D A

    1999-07-01

    The purpose of our study was to present descriptive findings of ocular abnormalities in vision screening examinations of abused and neglected children. We compared the prevalence and the nature of eye diseases and refractive error between abused and neglected boys staying at the Hathaway Home, a residential facility for abused children, and boys from neighboring Boys and Girls clubs. The children in the study received vision screening examinations through the UCLA Mobile Eye Clinic following a standard format. Clinical data were analyzed by chi-square test. The children with a history of abuse demonstrated significantly higher prevalence of myopia, astigmatism, and external eye disorders. Our study suggests that children with a history of abuse may be at higher risk for visual impairment. These visual impairments may be the long-term sequelae of child abuse.

  12. Global general pediatric surgery partnership: The UCLA-Mozambique experience.

    Science.gov (United States)

    Amado, Vanda; Martins, Deborah B; Karan, Abraar; Johnson, Brittni; Shekherdimian, Shant; Miller, Lee T; Taela, Atanasio; DeUgarte, Daniel A

    2017-09-01

    There has been increasing recognition of the disparities in surgical care throughout the world. Increasingly, efforts are being made to improve local infrastructure and training of surgeons in low-income settings. The purpose of this study was to review the first 5-years of a global academic pediatric general surgery partnership between UCLA and the Eduardo Mondlane University in Maputo, Mozambique. A mixed-methods approach was utilized to perform an ongoing needs assessment. A retrospective review of admission and operative logbooks was performed. Partnership activities were summarized. The needs assessment identified several challenges including limited operative time, personnel, equipment, and resources. Review of logbooks identified a high frequency of burn admissions and colorectal procedures. Partnership activities focused on providing educational resources, on-site proctoring, training opportunities, and research collaboration. This study highlights the spectrum of disease and operative case volume of a referral center for general pediatric surgery in sub-Saharan Africa, and it provides a context for academic partnership activities to facilitate training and improve the quality of pediatric general surgical care in limited-resource settings. Level IV. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Operational characteristics of pediatric radiology: Image display stations

    International Nuclear Information System (INIS)

    Taira, R.K.

    1987-01-01

    The display of diagnostic images is accomplished in the UCLA Pediatric Radiology Clinical Radiology Imaging System (CRIS) using 3 different types of digital viewing stations. These include a low resolution station with six 512 x 512 monitors, a high resolution station with three 1024 x 1024 monitors, and a very high resolution workstation with two 2048 x 2048 monitors. The display stations provide very basic image processing manipulations including zoom and scroll, contrast enhancement, and contrast reversal. The display stations are driven by a computer system which is dedicated for clinical use. During times when the clinical computer is unavailable (maintenance or system malfunction), the 512 x 512 workstation can be switched to operate from a research PACS system in the UCLA Image Processing Laboratory via a broadband communication network. Our initial clinical implementation involves digital viewing for pediatric radiology conferences. Presentation of inpatient cases use the six monitor 512 x 512 multiple viewing station. Later stages of the clinical implementation involve the use of higher resolution displays for the purpose of primary diagnosis from video displays

  14. Leveraging lean principles in creating a comprehensive quality program: The UCLA health readmission reduction initiative.

    Science.gov (United States)

    Afsar-Manesh, Nasim; Lonowski, Sarah; Namavar, Aram A

    2017-12-01

    UCLA Health embarked to transform care by integrating lean methodology in a key clinical project, Readmission Reduction Initiative (RRI). The first step focused on assembling a leadership team to articulate system-wide priorities for quality improvement. The lean principle of creating a culture of change and accountability was established by: 1) engaging stakeholders, 2) managing the process with performance accountability, and, 3) delivering patient-centered care. The RRI utilized three major lean principles: 1) A3, 2) root cause analyses, 3) value stream mapping. Baseline readmission rate at UCLA from 9/2010-12/2011 illustrated a mean of 12.1%. After the start of the RRI program, for the period of 1/2012-6/2013, the readmission rate decreased to 11.3% (p<0.05). To impact readmissions, solutions must evolve from smaller service- and location-based interventions into strategies with broader approach. As elucidated, a systematic clinical approach grounded in lean methodologies is a viable solution to this complex problem. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. The UCLA Multimodal Connectivity Database: A web-based platform for brain connectivity matrix sharing and analysis

    Directory of Open Access Journals (Sweden)

    Jesse A. Brown

    2012-11-01

    Full Text Available Brain connectomics research has rapidly expanded using functional MRI (fMRI and diffusion-weighted MRI (dwMRI. A common product of these varied analyses is a connectivity matrix (CM. A CM stores the connection strength between any two regions (nodes in a brain network. This format is useful for several reasons: 1 it is highly distilled, with minimal data size and complexity, 2 graph theory can be applied to characterize the network’s topology, and 3 it retains sufficient information to capture individual differences such as age, gender, intelligence quotient, or disease state. Here we introduce the UCLA Multimodal Connectivity Database (http://umcd.humanconnectomeproject.org, an openly available website for brain network analysis and data sharing. The site is a repository for researchers to publicly share CMs derived from their data. The site also allows users to select any CM shared by another user, compute graph theoretical metrics on the site, visualize a report of results, or download the raw CM. To date, users have contributed over 2000 individual CMs, spanning different imaging modalities (fMRI, dwMRI and disorders (Alzheimer’s, autism, Attention Deficit Hyperactive Disorder. To demonstrate the site’s functionality, whole brain functional and structural connectivity matrices are derived from 60 subjects’ (ages 26-45 resting state fMRI (rs-fMRI and dwMRI data and uploaded to the site. The site is utilized to derive graph theory global and regional measures for the rs-fMRI and dwMRI networks. Global and nodal graph theoretical measures between functional and structural networks exhibit low correspondence. This example demonstrates how this tool can enhance the comparability of brain networks from different imaging modalities and studies. The existence of this connectivity-based repository should foster broader data sharing and enable larger-scale meta analyses comparing networks across imaging modality, age group, and disease state.

  16. Multichannel far-infrared phase imaging for fusion plasmas

    International Nuclear Information System (INIS)

    Young, P.E.; Neikirk, D.P.; Tong, P.P.; Rutledge, D.B.; Luhmann, N.C. Jr.

    1985-01-01

    A 20-channel far-infrared imaging interferometer system has been used to obtain single-shot density profiles in the UCLA Microtor tokamak. This system differs from conventional multichannel interferometers in that the phase distribution produced by the plasma is imaged onto a single, monolithic, integrated microbolometer linear detector array and provides significantly more channels than previous far-infrared interferometers. The system has been demonstrated to provide diffraction-limited phase images of dielectric targets

  17. Experimental And Theoretical High Energy Physics Research At UCLA

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, Robert D. [University of California Los Angeles

    2013-07-22

    This is the final report of the UCLA High Energy Physics DOE Grant No. DE-FG02- 91ER40662. This report covers the last grant project period, namely the three years beginning January 15, 2010, plus extensions through April 30, 2013. The report describes the broad range of our experimental research spanning direct dark matter detection searches using both liquid xenon (XENON) and liquid argon (DARKSIDE); present (ICARUS) and R&D for future (LBNE) neutrino physics; ultra-high-energy neutrino and cosmic ray detection (ANITA); and the highest-energy accelerator-based physics with the CMS experiment and CERN’s Large Hadron Collider. For our theory group, the report describes frontier activities including particle astrophysics and cosmology; neutrino physics; LHC interaction cross section calculations now feasible due to breakthroughs in theoretical techniques; and advances in the formal theory of supergravity.

  18. UCLA intermediate energy nuclear physics and relativistic heavy ion physics. Annual report, February 1, 1983-January 31, 1984

    International Nuclear Information System (INIS)

    1984-01-01

    In this contract year the UCLA Intermediate Energy Group has continued to pursue a general set of problems in intermediate energy physics using new research tools and theoretical insights. Our program to study N-N scattering and proton-light nucleus scattering has been enhanced by a new polarized target facility (both hydrogen and deuterium) at the High Resolution Spectrometer (HRS) of the Los Alamos Meson Physics Facility (LAMPF). This facility has been constructed by our group in collaboration with physicists from KEK, LAMPF and the University of Minnesota; and the first set of experiments studying polarized beam-polarized target scattering at the HRS were completed this summer and early fall. The HRS mode of operation has led to some unique design features which are described. At the Bevalac, a new beam line spectrometer will be constructed for us during this year and next to significantly enhance our capability to study subthreshold k + , k - and anti p production in relativistic heavy ion collisions and to search for fractionally charged particles. During this period a proposal is being prepared for a very large acceptance spectrometer and its associated beam line which will be used to detect dilepton pairs produced in relativistic heavy ion collisions. In concert with these experimental projects, theoretical advances in the understanding of new data from the HRS, particularly spin transfer data, have been made by the UCLA group and are described

  19. Construction and initial operation of MHD PbLi facility at UCLA

    International Nuclear Information System (INIS)

    Kunugi, T.; Yokomine, T.; Ueki, Y.; Smolentsev, S.; Li, F.-C.; Sketchley, T.; Abdou, M.A.; Yuki, K.

    2014-01-01

    We review current accomplishments in Task 1-3 'Flow Control and Thermofluid Modeling' of the Japan-US 'TITAN' collaboration program. Our task focuses on experimental activities and also computer modeling of magnetohydrodynamic flows and heat and mass transfer of electrically conducting fluids under conditions relevant to fusion blankets. Since our task started, major efforts were taken to design, construct and test a new magnetohydrodynamic lead-lithium (PbLi) loop at UCLA, to accumulate the PbLi handling technology, and to develop a high-temperature ultrasonic Doppler velocimetry and a differential-pressure measurement system for PbLi flows. In the present paper, the loop construction, the electromagnetic pump performance test, our on-going experiments with the constructed loop are described. (author)

  20. UCLA1, a synthetic derivative of a gp120 RNA aptamer, inhibits entry of human immunodeficiency virus type 1 subtype C

    CSIR Research Space (South Africa)

    Mufhandu, Hazel T

    2012-05-01

    Full Text Available such as South Africa (47), where this study was conducted, we assessed the sensitivity of a large panel of subtype C isolates derived from adult and pediatric patients at different stages of HIV-1 infection against UCLA1. We examined its neutralization..., 34). These were derived from the CAPRISA 002 acute infection study cohort (18), subtype C reference panel (31), pediatric and AIDS patients? isolates (9, 17), and a subtype C consensus sequence clone (ConC) (26). The subtype C pseudoviruses were...

  1. Strengthening the fission reactor nuclear science and engineering program at UCLA. Final technical report

    International Nuclear Information System (INIS)

    Okrent, D.

    1997-01-01

    This is the final report on DOE Award No. DE-FG03-92ER75838 A000, a three year matching grant program with Pacific Gas and Electric Company (PG and E) to support strengthening of the fission reactor nuclear science and engineering program at UCLA. The program began on September 30, 1992. The program has enabled UCLA to use its strong existing background to train students in technological problems which simultaneously are of interest to the industry and of specific interest to PG and E. The program included undergraduate scholarships, graduate traineeships and distinguished lecturers. Four topics were selected for research the first year, with the benefit of active collaboration with personnel from PG and E. These topics remained the same during the second year of this program. During the third year, two topics ended with the departure o the students involved (reflux cooling in a PWR during a shutdown and erosion/corrosion of carbon steel piping). Two new topics (long-term risk and fuel relocation within the reactor vessel) were added; hence, the topics during the third year award were the following: reflux condensation and the effect of non-condensable gases; erosion/corrosion of carbon steel piping; use of artificial intelligence in severe accident diagnosis for PWRs (diagnosis of plant status during a PWR station blackout scenario); the influence on risk of organization and management quality; considerations of long term risk from the disposal of hazardous wastes; and a probabilistic treatment of fuel motion and fuel relocation within the reactor vessel during a severe core damage accident

  2. Photocathode driven linac at UCLA for FEL and plasma wakefield acceleration experiments

    International Nuclear Information System (INIS)

    Hartman, S.; Aghamir, F.; Barletta, W.; Cline, D.; Dodd, J.; Katsouleas, T.; Kolonko, J.; Park, S.; Pellegrini, C.; Rosenzweig, J.; Smolin, J.; Terrien, J.; Davis, J.; Hairapetian, G.; Joshi, C.; Luhmann, N. Jr.; McDermott, D.

    1991-01-01

    The UCLA compact 20-MeV/c electron linear accelerator is designed to produce a single electron bunch with a peak current of 200 A, an rms energy spread of 0.2% or less, and a short 1.2 picosecond rms pulse duration. The linac is also designed to minimize emittance growth down the beamline so as to obtain emittances of the order of 8πmm-mrad in the experimental region. The linac will feed two beamlines, the first will run straight into the undulator for FEL experiments while the second will be used for diagnostics, longitudinal bunch compression, and other electron beam experiments. Here the authors describe the considerations put into the design of the accelerating structures and the transport to the experimental areas

  3. Medical imaging, PACS, and imaging informatics: retrospective.

    Science.gov (United States)

    Huang, H K

    2014-01-01

    Historical reviews of PACS (picture archiving and communication system) and imaging informatics development from different points of view have been published in the past (Huang in Euro J Radiol 78:163-176, 2011; Lemke in Euro J Radiol 78:177-183, 2011; Inamura and Jong in Euro J Radiol 78:184-189, 2011). This retrospective attempts to look at the topic from a different angle by identifying certain basic medical imaging inventions in the 1960s and 1970s which had conceptually defined basic components of PACS guiding its course of development in the 1980s and 1990s, as well as subsequent imaging informatics research in the 2000s. In medical imaging, the emphasis was on the innovations at Georgetown University in Washington, DC, in the 1960s and 1970s. During the 1980s and 1990s, research and training support from US government agencies and public and private medical imaging manufacturers became available for training of young talents in biomedical physics and for developing the key components required for PACS development. In the 2000s, computer hardware and software as well as communication networks advanced by leaps and bounds, opening the door for medical imaging informatics to flourish. Because many key components required for the PACS operation were developed by the UCLA PACS Team and its collaborative partners in the 1980s, this presentation is centered on that aspect. During this period, substantial collaborative research efforts by many individual teams in the US and in Japan were highlighted. Credits are due particularly to the Pattern Recognition Laboratory at Georgetown University, and the computed radiography (CR) development at the Fuji Electric Corp. in collaboration with Stanford University in the 1970s; the Image Processing Laboratory at UCLA in the 1980s-1990s; as well as the early PACS development at the Hokkaido University, Sapporo, Japan, in the late 1970s, and film scanner and digital radiography developed by Konishiroku Photo Ind. Co. Ltd

  4. Construction and initial operation of MHD PbLi facility at UCLA

    Energy Technology Data Exchange (ETDEWEB)

    Smolentsev, S., E-mail: sergey@fusion.ucla.edu; Li, F.-C.; Morley, N.; Ueki, Y.; Abdou, M.; Sketchley, T.

    2013-06-15

    Highlights: • New MHD PbLi loop has been constructed and tested at UCLA. • Pressure diagnostics system has been developed and successfully tested. • Ultrasound Doppler velocimeter is tested as velocity diagnostics. • Experiments on pressure drop reduction have been performed. • Experiments on MHD flow in a duct with SiC flow channel insert are underway. -- Abstract: A magnetohydrodynamic flow facility MaPLE (Magnetohydrodynamic PbLi Experiment) that utilizes molten eutectic alloy lead–lithium (PbLi) as working fluid has been constructed and tested at University of California, Los Angeles. The loop operation parameters are: maximum magnetic field 1.8 T, PbLi temperature up to 350 °C, maximum PbLi flow rate with/without a magnetic field 15/50 l/min, maximum pressure head 0.15 MPa. The paper describes the loop itself and its major components, basic operation procedures, experience of handling PbLi, initial loop testing, flow diagnostics and current and near-future experiments. The obtained test results of the loop and its components have demonstrated that the new facility is fully functioning and ready for experimental studies of magnetohydrodynamic, heat and mass transfer phenomena in PbLi flows and also can be used in mock up testing in conditions relevant to fusion applications.

  5. An analysis of appropriate delivery of postoperative radiation therapy for endometrial cancer using the RAND/UCLA Appropriateness Method: Executive summary

    Directory of Open Access Journals (Sweden)

    Ellen Jones, MD, PhD

    2016-01-01

    Conclusions: This analysis based on the RAND/UCLA Method shows significant agreement with the 2014 endometrial Guideline. Areas of divergence, often in scenarios with low-level evidence, included use of external beam RT plus vaginal brachytherapy in stages II and III and external beam RT alone in early-stage patients. Furthermore, the analysis explores other important questions regarding management of this disease site.

  6. Educating European Corporate Communication Professionals for Senior Management Positions: A Collaboration between UCLA's Anderson School of Management and the University of Lugano

    Science.gov (United States)

    Forman, Janis

    2005-01-01

    UCLA's program in strategic management for European corporate communication professionals provides participants with a concentrated, yet selective, immersion in those management disciplines taught at U.S. business schools, topics that are essential to their work as senior advisors to CEOs and as leaders in the field. The choice of topics…

  7. Relativistic electron diffraction at the UCLA Pegasus photoinjector laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Musumeci, P. [UCLA Department of Physics and Astronomy, 475 Portola Plaza, Los Angeles, CA 90095-1547 (United States)], E-mail: musumeci@physics.ucla.edu; Moody, J.T.; Scoby, C.M. [UCLA Department of Physics and Astronomy, 475 Portola Plaza, Los Angeles, CA 90095-1547 (United States)

    2008-10-15

    Electron diffraction holds the promise to yield real-time resolution of atomic motion in an easily accessible environment like a university laboratory at a fraction of the cost of fourth-generation X-ray sources. Currently the limit in time-resolution for conventional electron diffraction is set by how short an electron pulse can be made. A very promising solution to maintain the highest possible beam intensity without excessive pulse broadening from space charge effects is to increase the electron energy to the MeV level where relativistic effects significantly reduce the space charge forces. Rf photoinjectors can in principle deliver up to 10{sup 7}-10{sup 8} electrons packed in bunches of {approx}100-fs length, allowing an unprecedented time resolution and enabling the study of irreversible phenomena by single-shot diffraction patterns. The use of rf photoinjectors as sources for ultrafast electron diffraction has been recently at the center of various theoretical and experimental studies. The UCLA Pegasus laboratory, commissioned in early 2007 as an advanced photoinjector facility, is the only operating system in the country, which has recently demonstrated electron diffraction using a relativistic beam from an rf photoinjector. Due to the use of a state-of-the-art ultrashort photoinjector driver laser system, the beam has been measured to be sub-100-fs long, at least a factor of 5 better than what measured in previous relativistic electron diffraction setups. Moreover, diffraction patterns from various metal targets (titanium and aluminum) have been obtained using the Pegasus beam. One of the main laboratory goals in the near future is to fully develop the rf photoinjector-based ultrafast electron diffraction technique with particular attention to the optimization of the working point of the photoinjector in a low-charge ultrashort pulse regime, and to the development of suitable beam diagnostics.

  8. Relativistic electron diffraction at the UCLA Pegasus photoinjector laboratory

    International Nuclear Information System (INIS)

    Musumeci, P.; Moody, J.T.; Scoby, C.M.

    2008-01-01

    Electron diffraction holds the promise to yield real-time resolution of atomic motion in an easily accessible environment like a university laboratory at a fraction of the cost of fourth-generation X-ray sources. Currently the limit in time-resolution for conventional electron diffraction is set by how short an electron pulse can be made. A very promising solution to maintain the highest possible beam intensity without excessive pulse broadening from space charge effects is to increase the electron energy to the MeV level where relativistic effects significantly reduce the space charge forces. Rf photoinjectors can in principle deliver up to 10 7 -10 8 electrons packed in bunches of ∼100-fs length, allowing an unprecedented time resolution and enabling the study of irreversible phenomena by single-shot diffraction patterns. The use of rf photoinjectors as sources for ultrafast electron diffraction has been recently at the center of various theoretical and experimental studies. The UCLA Pegasus laboratory, commissioned in early 2007 as an advanced photoinjector facility, is the only operating system in the country, which has recently demonstrated electron diffraction using a relativistic beam from an rf photoinjector. Due to the use of a state-of-the-art ultrashort photoinjector driver laser system, the beam has been measured to be sub-100-fs long, at least a factor of 5 better than what measured in previous relativistic electron diffraction setups. Moreover, diffraction patterns from various metal targets (titanium and aluminum) have been obtained using the Pegasus beam. One of the main laboratory goals in the near future is to fully develop the rf photoinjector-based ultrafast electron diffraction technique with particular attention to the optimization of the working point of the photoinjector in a low-charge ultrashort pulse regime, and to the development of suitable beam diagnostics

  9. Relativistic electron diffraction at the UCLA Pegasus photoinjector laboratory.

    Science.gov (United States)

    Musumeci, P; Moody, J T; Scoby, C M

    2008-10-01

    Electron diffraction holds the promise to yield real-time resolution of atomic motion in an easily accessible environment like a university laboratory at a fraction of the cost of fourth-generation X-ray sources. Currently the limit in time-resolution for conventional electron diffraction is set by how short an electron pulse can be made. A very promising solution to maintain the highest possible beam intensity without excessive pulse broadening from space charge effects is to increase the electron energy to the MeV level where relativistic effects significantly reduce the space charge forces. Rf photoinjectors can in principle deliver up to 10(7)-10(8) electrons packed in bunches of approximately 100-fs length, allowing an unprecedented time resolution and enabling the study of irreversible phenomena by single-shot diffraction patterns. The use of rf photoinjectors as sources for ultrafast electron diffraction has been recently at the center of various theoretical and experimental studies. The UCLA Pegasus laboratory, commissioned in early 2007 as an advanced photoinjector facility, is the only operating system in the country, which has recently demonstrated electron diffraction using a relativistic beam from an rf photoinjector. Due to the use of a state-of-the-art ultrashort photoinjector driver laser system, the beam has been measured to be sub-100-fs long, at least a factor of 5 better than what measured in previous relativistic electron diffraction setups. Moreover, diffraction patterns from various metal targets (titanium and aluminum) have been obtained using the Pegasus beam. One of the main laboratory goals in the near future is to fully develop the rf photoinjector-based ultrafast electron diffraction technique with particular attention to the optimization of the working point of the photoinjector in a low-charge ultrashort pulse regime, and to the development of suitable beam diagnostics.

  10. Neutralization of several adult and paediatric HIV-1 subtype C isolates using a shortened synthetic derivative of gp120 binding aptamer called UCLA1.

    CSIR Research Space (South Africa)

    Mufhandu, Hazel T

    2009-07-01

    Full Text Available This paper present a chemically synthesised derivative of the B40 parental aptamer, called UCLA1 (Cohen et al., 2008), was used for neutralization of endemic subtype C clinical isolates of HIV-1 from adult and paediatric patients and subtype B lab...

  11. An image database structure for pediatric radiology

    International Nuclear Information System (INIS)

    Mankovich, N.J.

    1987-01-01

    The operation of the Clinical Radiology Imaging System (CRIS) in Pediatric Radiology at UCLA relies on the orderly flow of text and image data among the three basic subsystems including acquisition, storage, and display. CRIS provides the radiologist, clinician, and technician with data at clinical image workstations by maintaining comprehensive database. CRIS is made up of sub-systems, each composed of one more programs or tasks which operate in parallel on a VAX-11/750 microcomputer in Pediatric Radiology. Tasks are coordinated through dynamic data structures that include system event flags and disk-resident queues. This report outlines: (1) the CRIS data model, (2) the flow of information among CRIS components, (3) the underlying database structures which support the acquisition, display, and storage of text and image information, and (4) current database statistics

  12. RESEÑA DE LAS I JORNADAS DE INVESTIGACIÓN DE INGENIERÍA CIVIL Y URBANISMO UCLA 2015

    OpenAIRE

    J. C. Rincón

    2016-01-01

    A través del presente ensayo, se esboza el acontecer de las I Jornadas de Investigación de Ingeniería Civil y Urbanismo UCLA 2015, la cual se desarrolló durante los días 15 y 16 de marzo del 2016, en las instalaciones del decanato de Ingeniería Civil de la Universidad Centroccidental Lisandro Alvarado. Se presentaron ponencias alusivas a trabajos de investigación relacionados a ingeniería civil, específicamente en las áreas de estructuras, hidráulica y sanitaria, ingeniería de construcción...

  13. UCLA's Molecular Screening Shared Resource: enhancing small molecule discovery with functional genomics and new technology.

    Science.gov (United States)

    Damoiseaux, Robert

    2014-05-01

    The Molecular Screening Shared Resource (MSSR) offers a comprehensive range of leading-edge high throughput screening (HTS) services including drug discovery, chemical and functional genomics, and novel methods for nano and environmental toxicology. The MSSR is an open access environment with investigators from UCLA as well as from the entire globe. Industrial clients are equally welcome as are non-profit entities. The MSSR is a fee-for-service entity and does not retain intellectual property. In conjunction with the Center for Environmental Implications of Nanotechnology, the MSSR is unique in its dedicated and ongoing efforts towards high throughput toxicity testing of nanomaterials. In addition, the MSSR engages in technology development eliminating bottlenecks from the HTS workflow and enabling novel assays and readouts currently not available.

  14. Development and validation of Australian aphasia rehabilitation best practice statements using the RAND/UCLA appropriateness method

    Science.gov (United States)

    Power, Emma; Thomas, Emma; Worrall, Linda; Rose, Miranda; Togher, Leanne; Nickels, Lyndsey; Hersh, Deborah; Godecke, Erin; O'Halloran, Robyn; Lamont, Sue; O'Connor, Claire; Clarke, Kim

    2015-01-01

    Objectives To develop and validate a national set of best practice statements for use in post-stroke aphasia rehabilitation. Design Literature review and statement validation using the RAND/UCLA Appropriateness Method (RAM). Participants A national Community of Practice of over 250 speech pathologists, researchers, consumers and policymakers developed a framework consisting of eight areas of care in aphasia rehabilitation. This framework provided the structure for the development of a care pathway containing aphasia rehabilitation best practice statements. Nine speech pathologists with expertise in aphasia rehabilitation participated in two rounds of RAND/UCLA appropriateness ratings of the statements. Panellists consisted of researchers, service managers, clinicians and policymakers. Main outcome measures Statements that achieved a high level of agreement and an overall median score of 7–9 on a nine-point scale were rated as ‘appropriate’. Results 74 best practice statements were extracted from the literature and rated across eight areas of care (eg, receiving the right referrals, providing intervention). At the end of Round 1, 71 of the 74 statements were rated as appropriate, no statements were rated as inappropriate, and three statements were rated as uncertain. All 74 statements were then rated again in the face-to-face second round. 16 statements were added through splitting existing items or adding new statements. Seven statements were deleted leaving 83 statements. Agreement was reached for 82 of the final 83 statements. Conclusions This national set of 82 best practice statements across eight care areas for the rehabilitation of people with aphasia is the first to be validated by an expert panel. These statements form a crucial component of the Australian Aphasia Rehabilitation Pathway (AARP) (http://www.aphasiapathway.com.au) and provide the basis for more consistent implementation of evidence-based practice in stroke rehabilitation. PMID:26137883

  15. Investigating plasma-rotation methods for the Space-Plasma Physics Campaign at UCLA's BAPSF.

    Science.gov (United States)

    Finnegan, S. M.; Koepke, M. E.; Reynolds, E. W.

    2006-10-01

    In D'Angelo et al., JGR 79, 4747 (1974), rigid-body ExB plasma flow was inferred from parabolic floating-potential profiles produced by a spiral ionizing surface. Here, taking a different approach, we report effects on barium-ion azimuthal-flow profiles using either a non-emissive or emissive spiral end-electrode in the WVU Q-machine. Neither electrode produced a radially-parabolic space-potential profile. The emissive spiral, however, generated controllable, radially-parabolic structure in the floating potential, consistent with a second population of electrons having a radially-parabolic parallel-energy profile. Laser-induced-fluorescence measurements of spatially resolved, azimuthal-velocity distribution functions show that, for a given flow profile, the diamagnetic drift of hot (>>0.2eV) ions overwhelms the ExB-drift contribution. Our experiments constitute a first attempt at producing controllable, rigid-body, ExB plasma flow for future experiments on the LArge-Plasma-Device (LAPD), as part of the Space-Plasma Physics Campaign (at UCLA's BAPSF).

  16. How does sagittal imbalance affect the appropriateness of surgical indications and selection of procedure in the treatment of degenerative scoliosis? Findings from the RAND/UCLA Appropriate Use Criteria study.

    Science.gov (United States)

    Daubs, Michael D; Brara, Harsimran S; Raaen, Laura B; Chen, Peggy Guey-Chi; Anderson, Ashaunta T; Asch, Steven M; Nuckols, Teryl K

    2018-05-01

    Degenerative lumbar scoliosis (DLS) is often associated with sagittal imbalance, which may affect patients' health outcomes before and after surgery. The appropriateness of surgery and preferred operative approaches has not been examined in detail for patients with DLS and sagittal imbalance. The goals of this article were to describe what is currently known about the relationship between sagittal imbalance and health outcomes among patients with DLS and to determine how indications for surgery in patients with DLS differ when sagittal imbalance is present. This study included a literature review and an expert panel using the RAND/University of California at Los Angeles (UCLA) Appropriateness Method. To develop appropriate use criteria for DLS, researchers at the RAND Corporation recently employed the RAND/UCLA Appropriateness Method, which involves a systematic review of the literature and multidisciplinary expert panel process. Experts reviewed a synopsis of published literature and rated the appropriateness of five common operative approaches for 260 different clinical scenarios. In the present work, we updated the literature review and compared panelists' ratings in scenarios where imbalance was present versus absent. This work was funded by the Collaborative Spine Research Foundation, a group of surgical specialty societies and device manufacturers. On the basis of 13 eligible studies that examined sagittal imbalance and outcomes in patients with DLS, imbalance was associated with worse functional status in the absence of surgery and worse symptoms and complications postoperatively. Panelists' ratings demonstrated a consistent pattern across the diverse clinical scenarios. In general, when imbalance was present, surgery was more likely to be appropriate or necessary, including in some situations where surgery would otherwise be inappropriate. For patients with moderate to severe symptoms and imbalance, a deformity correction procedure was usually appropriate

  17. Far-infrared imaging arrays for fusion plasma density and magnetic field measurements

    International Nuclear Information System (INIS)

    Neikirk, D.P.; Rutledge, D.B.

    1982-01-01

    Far-infrared imaging detector arrays are required for the determination of density and local magnetic field in fusion plasmas. Analytic calculations point out the difficulties with simple printed slot and dipole antennas on ungrounded substrates for use in submillimeter wave imaging arrays because of trapped surface waves. This is followed by a discussion of the use of substrate-lens coupling to eliminate the associated trapped surface modes responsible for their poor performance. This integrates well with a modified bow-tie antenna and permits diffraction-limited imaging. Arrays using bismuth microbolometers have been successfully fabricated and tested at 1222μm and 119μm. A 100 channel pilot experiment designed for the UCLA Microtor tokamak is described. (author)

  18. The Benefits of Adding SETI to the University Curriculum and What We Have Learned from a SETI Course Recently Offered at UCLA

    Science.gov (United States)

    Lesyna, Larry; Margot, Jean-Luc; Greenberg, Adam; Shinde, Akshay; Alladi, Yashaswi; Prasad MN, Srinivas; Bowman, Oliver; Fisher, Callum; Gyalay, Szilard; McKibbin, William; Miles, Brittany E.; Nguyen, Donald; Power, Conor; Ramani, Namrata; Raviprasad, Rashmi; Santana, Jesse

    2017-01-01

    We advocate for the inclusion of a full-term course entirely devoted to SETI in the university curriculum. SETI usually warrants only a few lectures in a traditional astronomy or astrobiology course. SETI’s rich interdisciplinary character serves astronomy students by introducing them to scientific and technological concepts that will aid them in their dissertation research or later in their careers. SETI is also an exciting topic that draws students from other disciplines and teaches them astronomical concepts that they might otherwise never encounter in their university studies. We have composed syllabi that illustrate the breadth and depth that SETI courses provide for advanced undergraduate or graduate students. The syllabi can also be used as a guide for an effective SETI course taught at a descriptive level.After a pilot course in 2015, UCLA formally offered a course titled "EPSS C179/279 - Search for Extraterrestrial Intelligence: Theory and Applications" in Spring 2016. The course was designed for advanced undergraduate students and graduate students in the science, technical, engineering, and mathematical fields. In 2016, 9 undergraduate students and 5 graduate students took the course. Students designed an observing sequence for the Arecibo and Green Bank telescopes, observed known planetary systems remotely, wrote a sophisticated and modular data processing pipeline, analyzed the data, and presented the results. In the process, they learned radio astronomy fundamentals, software development, signal processing, and statistics. The instructor believes that the students were eager to learn because of the engrossing nature of SETI. The students rated the course highly, in part because of the observing experience and the teamwork approach. The next offering will be in Spring 2017.See lxltech.com and seti.ucla.edu

  19. Image acquisition for the pediatric radiology PACS module

    International Nuclear Information System (INIS)

    Ho, B.K.; Morioka, C.; Mankovich, N.J.; Stewart, B.; Huang, H.K.

    1987-01-01

    The prototype PACS module implemented at UCLA's pediatric radiology section has multi-modality access to image data from any of the three types of sources: digital modalities (i.e. CT, MR, and DSA), the Fuji Computed Radiography unit (FCR), and laser film digitizers. An interface unit was built to facilitate real-time data transfer from the FCR to the VAX11/750 which serves as the PACS host computer. The design of the interface unit, methods for linking to digital modalities, and characteristics of two film digitizers are described

  20. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    Science.gov (United States)

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  1. Development and validation of Australian aphasia rehabilitation best practice statements using the RAND/UCLA appropriateness method.

    Science.gov (United States)

    Power, Emma; Thomas, Emma; Worrall, Linda; Rose, Miranda; Togher, Leanne; Nickels, Lyndsey; Hersh, Deborah; Godecke, Erin; O'Halloran, Robyn; Lamont, Sue; O'Connor, Claire; Clarke, Kim

    2015-07-02

    To develop and validate a national set of best practice statements for use in post-stroke aphasia rehabilitation. Literature review and statement validation using the RAND/UCLA Appropriateness Method (RAM). A national Community of Practice of over 250 speech pathologists, researchers, consumers and policymakers developed a framework consisting of eight areas of care in aphasia rehabilitation. This framework provided the structure for the development of a care pathway containing aphasia rehabilitation best practice statements. Nine speech pathologists with expertise in aphasia rehabilitation participated in two rounds of RAND/UCLA appropriateness ratings of the statements. Panellists consisted of researchers, service managers, clinicians and policymakers. Statements that achieved a high level of agreement and an overall median score of 7-9 on a nine-point scale were rated as 'appropriate'. 74 best practice statements were extracted from the literature and rated across eight areas of care (eg, receiving the right referrals, providing intervention). At the end of Round 1, 71 of the 74 statements were rated as appropriate, no statements were rated as inappropriate, and three statements were rated as uncertain. All 74 statements were then rated again in the face-to-face second round. 16 statements were added through splitting existing items or adding new statements. Seven statements were deleted leaving 83 statements. Agreement was reached for 82 of the final 83 statements. This national set of 82 best practice statements across eight care areas for the rehabilitation of people with aphasia is the first to be validated by an expert panel. These statements form a crucial component of the Australian Aphasia Rehabilitation Pathway (AARP) (http://www.aphasiapathway.com.au) and provide the basis for more consistent implementation of evidence-based practice in stroke rehabilitation. Published by the BMJ Publishing Group Limited. For permission to use (where not already

  2. The fitness of copings constructed over UCLA abutments and the implant, constructed by different techniques: casting and casting with laser welding Adaptação de copings de ritânio ao implante, construídos sobre pilares UCLA por duas técnicas: fundição e fundição com soldagem de bordo laser

    Directory of Open Access Journals (Sweden)

    Elza Maria Valadares da Costa

    2004-12-01

    Full Text Available The alternative for the reposition of a missing tooth is the osteointegrated implant being the passive adaptation between the prosthodontic structure and the implant a significant factor for the success of this experiment, a comparative study was done between the two methods for confectioning a single prosthodontic supported by an implant. To do so a screwed implant with a diameter of 3.75mm and a length of 10.0mm (3i Implant innovations, Brasil was positioned in the middle of a resin block and over it we screwed 15 UCLA abutments shaped and anti-rotationable (137CNB, Conexão Sistemas de Próteses, Brasil with a torque of 20N.cm without any laboratorial procedure (control group - CTRLG. From a silicon model 15 UCLA-type calcinatable compounds (56CNB, Conexão Sistemas de Próteses, Brasil were screwed (20 N.cm, received a standard waxing (plain buccal surface and were cast in titanium (casting group - CG and other 15 compounds, UCLA - type shaped in titanium (137 CNB, Conexão Sistemas de Próteses, Brasil received the same standard waxing. These last copings were cast in titanium separated from each other and were laser-welded to the respective abutments on their border (Laser-welding group - LWG. The border adaptation was observed in the implant/compound interface, under measurement microscope, on the y axis, in 4 vestibular, lingual, mesial and distal referential points previously marked on the block. The arithmetical means were obtained and an exploratory data analysis was performed to determine the most appropriate statistical test. Descriptive statistics data (µm for Control (mean±standard deviation: 13.50 ± 21.80; median 0.00, for Casting (36.20±12.60; 37.00, for Laser (10.50 ±12.90; 3.00 were submitted to Kruskal-Wallis ANOVA, alpha = 5%. Results test showed that distorsion median values differ statistically (kw = 17.40; df =2; p = 0.001A reposição de um elemento dentário pode ser feita por um implante osseointegrado sendo que a

  3. Simulations of the BNL/SLAC/UCLA 1.6 cell emittance compensated photocathode RF gun low energy beam line

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Winick, H.

    1995-01-01

    A dedicated low energy (2 to 10 MeV) experimental beam line is now under construction at Brookhaven National Laboratories Accelerator Test Facility (BNL/ATF) for photocathode RF gun testing and photoemission experiments. The design of the experimental line, using the 1.6 cell photocathode RF gun developed by the BNL/SLAC/UCLA RF gun collaboration is presented. Detailed beam dynamics simulations were performed for the 1.6 cell RF gun injector using a solenoidal emittance compensation technique. An experimental program for testing the 1.6 cell RF gun is presented. This program includes beam loading caused by dark current, higher order mode field measurements, integrated and slice emittance measurements using a pepper-pot and RF kicker cavity

  4. UCLA Particle and Nuclear Physics Research Group, 1993 progress report

    International Nuclear Information System (INIS)

    Nefkens, B.M.K.; Clajus, M.; Price, J.W.; Tippens, W.B.; White, D.B.

    1993-09-01

    The research programs of the UCLA Particle and Nuclear Physics Research Group, the research objectives, results of experiments, the continuing activities and new initiatives are presented. The primary goal of the research is to test the symmetries and invariances of particle/nuclear physics with special emphasis on investigating charge symmetry, isospin invariance, charge conjugation, and CP. Another important part of our work is baryon spectroscopy, which is the determination of the properties (mass, width, decay modes, etc.) of particles and resonances. We also measure some basic properties of light nuclei, for example the hadronic radii of 3 H and 3 He. Special attention is given to the eta meson, its production using photons, electrons, π ± , and protons, and its rare and not-so-rare decays. In Section 1, the physics motivation of our research is outlined. Section 2 provides a summary of the research projects. The status of each program is given in Section 3. We discuss the various experimental techniques used, the results obtained, and we outline the plans for the continuing and the new research. Details are presented of new research that is made possible by the use of the Crystal Ball Detector, a highly segmented NaI calorimeter and spectrometer with nearly 4π acceptance (it was built and used at SLAC and is to be moved to BNL). The appendix contains an update of the bibliography, conference participation, and group memos; it also indicates our share in the organization of conferences, and gives a listing of the colloquia and seminars presented by us

  5. A framework for improving access and customer service times in health care: application and analysis at the UCLA Medical Center.

    Science.gov (United States)

    Duda, Catherine; Rajaram, Kumar; Barz, Christiane; Rosenthal, J Thomas

    2013-01-01

    There has been an increasing emphasis on health care efficiency and costs and on improving quality in health care settings such as hospitals or clinics. However, there has not been sufficient work on methods of improving access and customer service times in health care settings. The study develops a framework for improving access and customer service time for health care settings. In the framework, the operational concept of the bottleneck is synthesized with queuing theory to improve access and reduce customer service times without reduction in clinical quality. The framework is applied at the Ronald Reagan UCLA Medical Center to determine the drivers for access and customer service times and then provides guidelines on how to improve these drivers. Validation using simulation techniques shows significant potential for reducing customer service times and increasing access at this institution. Finally, the study provides several practice implications that could be used to improve access and customer service times without reduction in clinical quality across a range of health care settings from large hospitals to small community clinics.

  6. Preliminary conceptual design for a 510 MeV electron/positron injector for a UCLA φ factory

    International Nuclear Information System (INIS)

    Dahlbacka, G.; Hartline, R.; Barletta, W.; Pellegrini, C.

    1991-01-01

    UCLA is proposing a compact suer conducting high luminosity (10 32-33 cm -2 sec -1 ) e + e - collider for a φ factory. To achieve the required e + e - currents, full energy injections from a linac with intermediate storage in a Positron Accumulator Ring (PAR) is used. The elements of the linac are outlined with cost and future flexibility in mind. The preliminary conceptual design starts with a high current gun similar in design to those developed at SLAC and at ANL (for the APS). Four 4-section linac modules follow, each driven by a 60 MW klystron with a 1 μsec macropulse and an average current of 8.6 A. The first 4-section model is used to create positrons in a tungsten target at 186 MeV. The three remaining three modules are used to accelerate the e + e - beam to 558 MeV (no load limit) for injection into the PAR

  7. Wavelet-based blind identification of the UCLA Factor building using ambient and earthquake responses

    International Nuclear Information System (INIS)

    Hazra, B; Narasimhan, S

    2010-01-01

    Blind source separation using second-order blind identification (SOBI) has been successfully applied to the problem of output-only identification, popularly known as ambient system identification. In this paper, the basic principles of SOBI for the static mixtures case is extended using the stationary wavelet transform (SWT) in order to improve the separability of sources, thereby improving the quality of identification. Whereas SOBI operates on the covariance matrices constructed directly from measurements, the method presented in this paper, known as the wavelet-based modified cross-correlation method, operates on multiple covariance matrices constructed from the correlation of the responses. The SWT is selected because of its time-invariance property, which means that the transform of a time-shifted signal can be obtained as a shifted version of the transform of the original signal. This important property is exploited in the construction of several time-lagged covariance matrices. The issue of non-stationary sources is addressed through the formation of several time-shifted, windowed covariance matrices. Modal identification results are presented for the UCLA Factor building using ambient vibration data and for recorded responses from the Parkfield earthquake, and compared with published results for this building. Additionally, the effect of sensor density on the identification results is also investigated

  8. Validation of the UCLA Child Post traumatic stress disorder-reaction index in Zambia

    Directory of Open Access Journals (Sweden)

    Cohen Judith A

    2011-09-01

    Full Text Available Abstract Background Sexual violence against children is a major global health and human rights problem. In order to address this issue there needs to be a better understanding of the issue and the consequences. One major challenge in accomplishing this goal has been a lack of validated child mental health assessments in low-resource countries where the prevalence of sexual violence is high. This paper presents results from a validation study of a trauma-focused mental health assessment tool - the UCLA Post-traumatic Stress Disorder - Reaction Index (PTSD-RI in Zambia. Methods The PTSD-RI was adapted through the addition of locally relevant items and validated using local responses to three cross-cultural criterion validity questions. Reliability of the symptoms scale was assessed using Cronbach alpha analyses. Discriminant validity was assessed comparing mean scale scores of cases and non-cases. Concurrent validity was assessed comparing mean scale scores to a traumatic experience index. Sensitivity and specificity analyses were run using receiver operating curves. Results Analysis of data from 352 youth attending a clinic specializing in sexual abuse showed that this adapted PTSD-RI demonstrated good reliability, with Cronbach alpha scores greater than .90 on all the evaluated scales. The symptom scales were able to statistically significantly discriminate between locally identified cases and non-cases, and higher symptom scale scores were associated with increased numbers of trauma exposures which is an indication of concurrent validity. Sensitivity and specificity analyses resulted in an adequate area under the curve, indicating that this tool was appropriate for case definition. Conclusions This study has shown that validating mental health assessment tools in a low-resource country is feasible, and that by taking the time to adapt a measure to the local context, a useful and valid Zambian version of the PTSD-RI was developed to detect

  9. A radiographic image archive system on digital optical disks

    International Nuclear Information System (INIS)

    Mankovich, N.J.; Taira, R.K.; Cho, P.S.; Wong, W.K.; Stewart, B.K.; Huang, H.K.

    1986-01-01

    The recent introduction of projection computed radiography (CR) systems allows radiology departments to consider digital operation in over 90% of performed procedures. Ideally, current patient procedures from CT, CT, and MR along with laser-digitized historical films should be centrally stored at their full digital resolution. Magnetic disks, because of their limited storage capacity and expense, can only retain these data on a limited basis. The author devised an optical disk archive system which automatically stores images directly onto 2.6-gigabyte optical cartridges without recourse to film. This system is in full clinical operation in the UCLA Pediatric Radiology Section of the authors' department. From this experience they present (a) an analysis of the digital archiving requirements of the Pediatric Radiology Section based on CR, CT, MR, and laser digitized films; (b) the archive and retrieval methods along with performance statistics; and (c) the procedure for assuring digital image integrity

  10. Science and Engineering of the Environment of Los Angeles: A GK-12 Experiment at Developing Science Communications Skills in UCLA's Graduate Program

    Science.gov (United States)

    Moldwin, M. B.; Hogue, T. S.; Nonacs, P.; Shope, R. E.; Daniel, J.

    2008-12-01

    Many science and research skills are taught by osmosis in graduate programs with the expectation that students will develop good communication skills (speaking, writing, and networking) by observing others, attending meetings, and self reflection. A new National Science Foundation Graduate Teaching Fellows in K- 12 Education (GK-12; http://ehrweb.aaas.org/gk12new/) program at UCLA (SEE-LA; http://measure.igpp.ucla.edu/GK12-SEE-LA/overview.html ) attempts to make the development of good communication skills an explicit part of the graduate program of science and engineering students. SEE-LA places the graduate fellows in two pairs of middle and high schools within Los Angeles to act as scientists-in- residence. They are partnered with two master science teachers and spend two-days per week in the classroom. They are not student teachers, or teacher aides, but scientists who contribute their content expertise, excitement and experience with research, and new ideas for classroom activities and lessons that incorporate inquiry science. During the one-year fellowship, the graduate students also attend a year-long Preparing Future Faculty seminar that discusses many skills needed as they begin their academic or research careers. Students are also required to include a brief (two-page) summary of their research that their middle or high school students would be able to understand as part of their published thesis. Having students actively thinking about and communicating their science to a pre-college audience provides important science communication training and helps contribute to science education. University and local pre- college school partnerships provide an excellent opportunity to support the development of graduate student communication skills while also contributing significantly to the dissemination of sound science to K-12 teachers and students.

  11. The librarian as research informationist: a case study.

    Science.gov (United States)

    Federer, Lisa

    2013-10-01

    How can an embedded research informationist add value to the scientific output of research teams? The University of California-Los Angeles (UCLA) Louise M. Darling Biomedical Library is an academic health sciences library serving the clinical, educational, and research needs of the UCLA community. A grant from the National Library of Medicine funded a librarian to join a UCLA research team as an informationist. The informationist meets regularly with the research team and provides guidance related to data management, preservation, and other information-related issues. Early results suggest that the informationist's involvement has influenced the team's data gathering, storage, and curation methods. The UCLA Library has also changed the librarian's title to research informationist to reflect the new activities that she performs. The research informationist role provides an opportunity for librarians to become effective members of research teams and improve research output.

  12. Time series analysis of brain regional volume by MR image

    International Nuclear Information System (INIS)

    Tanaka, Mika; Tarusawa, Ayaka; Nihei, Mitsuyo; Fukami, Tadanori; Yuasa, Tetsuya; Wu, Jin; Ishiwata, Kiichi; Ishii, Kenji

    2010-01-01

    The present study proposed a methodology of time series analysis of volumes of frontal, parietal, temporal and occipital lobes and cerebellum because such volumetric reports along the process of individual's aging have been scarcely presented. Subjects analyzed were brain images of 2 healthy males and 18 females of av. age of 69.0 y, of which T1-weighted 3D SPGR (spoiled gradient recalled in the steady state) acquisitions with a GE SIGNA EXCITE HD 1.5T machine were conducted for 4 times in the time series of 42-50 months. The image size was 256 x 256 x (86-124) voxels with digitization level 16 bits. As the template for the regions, the standard gray matter atlas (icbn452 a tlas p robability g ray) and its labeled one (icbn.Labels), provided by UCLA Laboratory of Neuro Imaging, were used for individual's standardization. Segmentation, normalization and coregistration were performed with the MR imaging software SPM8 (Statistic Parametric Mapping 8). Volumes of regions were calculated as their voxel ratio to the whole brain voxel in percent. It was found that the regional volumes decreased with aging in all above lobes examined and cerebellum in average percent per year of -0.11, -0.07, -0.04, -0.02, and -0.03, respectively. The procedure for calculation of the regional volumes, which has been manually operated hitherto, can be automatically conducted for the individual brain using the standard atlases above. (T.T.)

  13. Low Cost Desktop Image Analysis Workstation With Enhanced Interactive User Interface

    Science.gov (United States)

    Ratib, Osman M.; Huang, H. K.

    1989-05-01

    A multimodality picture archiving and communication system (PACS) is in routine clinical use in the UCLA Radiology Department. Several types workstations are currently implemented for this PACS. Among them, the Apple Macintosh II personal computer was recently chosen to serve as a desktop workstation for display and analysis of radiological images. This personal computer was selected mainly because of its extremely friendly user-interface, its popularity among the academic and medical community and its low cost. In comparison to other microcomputer-based systems the Macintosh II offers the following advantages: the extreme standardization of its user interface, file system and networking, and the availability of a very large variety of commercial software packages. In the current configuration the Macintosh II operates as a stand-alone workstation where images are imported from a centralized PACS server through an Ethernet network using a standard TCP-IP protocol, and stored locally on magnetic disk. The use of high resolution screens (1024x768 pixels x 8bits) offer sufficient performance for image display and analysis. We focused our project on the design and implementation of a variety of image analysis algorithms ranging from automated structure and edge detection to sophisticated dynamic analysis of sequential images. Specific analysis programs were developed for ultrasound images, digitized angiograms, MRI and CT tomographic images and scintigraphic images.

  14. Recent Developments in Instrumentation for Pre-Clinical Imaging Studies

    International Nuclear Information System (INIS)

    Meikle, S.R.

    2002-01-01

    Full text: Recent advances in imaging instrumentation have led to a variety of tomograph designs for dedicated pre clinical imaging of laboratory animals. These advances make it possible to image and quantify the kinetics of radiolabelled pharmaceuticals in a wide range of animal models from rodents to non-human primates. Applications include evaluation of promising new radiopharmaceuticals, study of the molecular origins of human disease and evaluation of new forms of therapy. These applications and advances in instrumentation are equally applicable to positron emitters and single photon emitters. This paper provides an overview of recent advances which have led to the current state-of-the-art in pre clinical imaging. The common inorganic scintillators that have been used for SPECT and PET, including some of the promising materials recently studied. The current crystal of choice for SPECT imaging is NaI(Tl) because of its high light output and density which make it well suited to imaging photons in the 100-200 keV range. However, NaI(Tl) has the disadvantage that it must be hermetically sealed to prevent absorption of moisture from the environment. Therefore, investigators have explored a number of alternative inorganic crystals, including CsI(Tl) and cerium-doped yttrium aluminium perovskite (YAP), as well as solid state detectors such as cadmium zinc telluride (CZT). Many of the crystals used in SPECT have also been tried for PET, including NaI(Tl) and YAP. However these crystals have lower stopping power than BGO and NaI(Tl) is also relatively slow. A very promising scintillator for PET is cerium-doped lutetium oxyorthosilicate (LSO) (1) which has similar stopping power to BGO and relatively high light output and fast decay. The first PET scanner to use LSO was the UCLA animal scanner, microPET, which also makes use of a number of other new technologies and unique design features. Recently, improvements in multi-anode and crossed wire position sensitive

  15. Theoretical and Experimental Studies in Accelerator Physics

    Energy Technology Data Exchange (ETDEWEB)

    Rosenzweig, James [Univ. of California, Los Angeles, CA (United States). Dept. of Physics and Astronomy

    2017-03-08

    . We note also that PBPL graduates remain as close elaborators for the program after leaving UCLA. The UCLA PBPL program is a foremost developer of on-campus facilities, such as the Neptune and Pegasus Laboratories, providing a uniquely strong environment for student-based research. In addition, the PBPL is a strong user of off-campus national lab facilities, such as SLAC FACET and NLCTA, and the BNL ATF. UCLA has also vigorously participated in the development of these facilities. The dual emphases on off- and on-campus opportunities permit the PBPL to address in an agile way a wide selection of cutting-edge research topics. The topics embraced by this proposal illustrate this program aspect well. These include: GV/m dielectric wakefield acceleration/coherent Cerenkov radiation experiments at FACET (E-201) and the ATF; synergistic laser-excited dielectric accelerator and light source development; plasma wakefield (PWFA) experiments on “Trojan horse” ionization injection (FACET E-210), quasi-nonlinear PWFA at BNL and the production at Neptune high transformer ratio plasma wakes; the inauguration of a new type of RF photoinjector termed “hybrid” at UCLA, and application to PWFA; space-charge dominated beam and cathode/near cathode physics; the study of advanced IFEL systems, for very high energy gain and utilization of novel OAM modes; the physcis of inverse Compton scattering (ICS), with applications to e+ production and γγ colliders; electron diffraction; and advanced beam diagnostics using coherent imaging techniques. These subjects are addressed under the leadership of PBPL director Prof. James Rosenzweig in Task A, and Prof. Pietro Musumeci in Task J, which was initiated following his OHEP Outstanding Junior Investigator award.

  16. Activated learning; providing structure in global health education at the David Geffen School of Medicine at the University of California, Los Angeles (UCLA)- a pilot study.

    Science.gov (United States)

    Jordan, Jaime; Hoffman, Risa; Arora, Gitanjli; Coates, Wendy

    2016-02-16

    Global health rotations are increasingly popular amongst medical students. The training abroad is highly variable and there is a recognized need for global health curriculum development. We sought to create and evaluate a curriculum, applicable to any global health rotation, that requires students to take an active role in their education and promotes engagement. Prospective, observational, mixed method study of 4th year medical students enrolled in global health courses at UCLA in 2011-12. Course directors identified 4 topics common to all rotations (traditional medicine, health systems, limited resources, pathology) and developed activities for students to complete abroad: observation, interview and reflection on resources, pathology, medical practices; and compare/contrast their experience with the US healthcare system. Students posted responses on a discussion board moderated by US faculty. After the rotation, students completed an anonymous internet-based evaluative survey. Responses were tabulated. Qualitative data from discussion board postings and free response survey items were analyzed using the framework method. 14 (100 %) students completed the Activated Learning assignment. 12 submitted the post rotation survey (85.7 %). Activated Learning enhanced GH education for 67 % and facilitated engagement in the local medical culture for 67 %. Qualitative analysis of discussion board posting demonstrated multiple areas of knowledge gain and analysis of free response survey items revealed 5 major themes supporting Activated Learning: guided learning, stimulation of discussion, shared interactions, cultural understanding, and knowledge of global healthcare systems. Increased interactivity emerged as the major theme for future improvement. The results of this study suggest that an Activated Learning program may enhance education, standardize curricular objectives across multiple sites and promote engagement in local medical culture, pathology and delivery

  17. Magnetic resonance imaging for the clinical management of rectal cancer patients: recommendations from the 2012 European Society of Gastrointestinal and Abdominal Radiology (ESGAR) consensus meeting

    Energy Technology Data Exchange (ETDEWEB)

    Beets-Tan, Regina G.H. [Maastricht University Medical Centre+, Maastricht (Netherlands); Maastricht University Medical Centre+, Department of Radiology, P.O. Box 5800, AZ, Maastricht (Netherlands); Lambregts, Doenja M.J.; Maas, Monique [Maastricht University Medical Centre+, Maastricht (Netherlands); Bipat, Shandra; Stoker, Jaap [Academic Medical Centre, Amsterdam (Netherlands); Barbaro, Brunella [Catholic University School of Medicine, Rome (Italy); Caseiro-Alves, Filipe; Curvo-Semedo, Luis [Coimbra University Hospitals, Coimbra (Portugal); Fenlon, Helen M. [Mater Misericordiae University Hospital, Dublin (Ireland); Gollub, Marc J. [Memorial Sloan-Kettering Cancer Center, New York (United States); Gourtsoyianni, Sofia [University Hospital of Heraklion, Crete (Greece); Guy' s and St. Thomas' NHS FT, London (United Kingdom); Halligan, Steve; Taylor, Stuart A. [University College London, Centre for Medical Imaging, London (United Kingdom); Hoeffel, Christine [Reims University Hospital, Reims (France); Kim, Seung Ho [Inje University Haeundae Paik Hospital, Busan (Korea, Republic of); Laghi, Andrea [Sapienza - University of Rome, Rome (Italy); Maier, Andrea [Medical University of Vienna, Vienna (Austria); Rafaelsen, Soeren R. [Vejle Hospital, Vejle (Denmark); Torkzad, Michael R. [Uppsala University, Uppsala (Sweden); Blomqvist, Lennart [Karolinska University Hospital and Karolinska Institutet, Stockholm (Sweden)

    2013-09-15

    To develop guidelines describing a standardised approach regarding the acquisition, interpretation and reporting of magnetic resonance imaging (MRI) for clinical staging and restaging of rectal cancer. A consensus meeting of 14 abdominal imaging experts from the European Society of Gastrointestinal and Abdominal Radiology (ESGAR) was conducted following the RAND-UCLA Appropriateness Method. Two independent (non-voting) chairs facilitated the meeting. Two hundred and thirty-six items were scored by participants for appropriateness and classified subsequently as appropriate or inappropriate (defined by {>=} 80 % consensus) or uncertain (defined by < 80 % consensus). Items not reaching 80 % consensus were noted. Consensus was reached for 88 % of items: recommendations regarding hardware, patient preparation, imaging sequences, angulation, criteria for MRI assessment and MRI reporting were constructed from these. These expert consensus recommendations can be used as clinical guidelines for primary staging and restaging of rectal cancer using MRI. (orig.)

  18. Final Report UCLA-Thermochemical Storage with Anhydrous Ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Lavine, Adrienne [Univ. of California, Los Angeles, CA (United States)

    2018-02-05

    associated with storage of gas phase components. 3. While this project is primarily concerned with high-temperature heat recovery and methods to store the gaseous components, it is also important to consider the feasibility of the entire system. Consequently, an additional goal was to perform analysis to show the feasibility of integrating endothermic reactors within a tower receiver. A conceptual design of an ammonia dissociation receiver/reactor has been developed that fits into the same size cylindrical envelope as the molten salt receiver in SAM, and has the same design thermal capacity. The calculated thermal efficiency of this receiver is 94.6%. Thus, this investigation has established the technical feasibility of a surround field tower system using ammonia dissociation. With these challenges addressed, we proceeded to design a full-scale synthesis and heat recovery system. A model was developed and validated by comparison with our experimental data. A parametric study showed, among other things, the importance of using small tube diameters and spacing to enhance heat transfer. Multi-parameter optimization was used to find a design that minimizes the wall material volume. Finally, cost estimation shows that the ammonia system has good prospects of meeting the Sunshot 15(USD)/kWht target: estimated costs of the entire synthesis system for the 220 MWt plant with 6 hours of storage are 13(USD)/kWht using salt cavern storage and 18(USD)/kWht using shaft drilling. Costs per kWht are even lower with more hours of storage. With the established technology of ammonia synthesis as a starting point, the successes of the project have mitigated technical risks associated with high-temperature synthesis reaction, underground storage, and tower receiver design. Estimated costs are less than 15(USD)/kWht with salt cavern storage. It is now possible to map a time line to commercial deployment that is likely to be shorter and less risky than other thermochemical cycles under active

  19. Image registration in gastric emptying studies

    International Nuclear Information System (INIS)

    Shuter, B.; Cooper, R.G.

    1998-01-01

    Full text: We have previously shown that image registration, based upon a two-dimensional cross-correlation (CC) of logarithmic Laplacian images (LLI), corrected motion in biliary studies in up to 90% of cases with minimal artifact. We have now applied the same technique to gastric emptying studies (GES). GES were acquired on an LFOV gamma camera over a two-hour period as 20-26 pairs of anterior-posterior frames (30 second duration and 64 x 64 matrix) for both solid and liquid components. All images were manually registered so that the solid contents of the stomach lay within an operator-drawn ROI. The anterior images of the solid component for 30 randomly selected patients were subjected to further image registration using CC of LLI, CC of raw images (Rl) (a common approach to image registration) and CC of Laplacian images (Ll). All images were aligned to the third image of the study, on which an ROI was drawn to outline the stomach. The number of images in which stomach counts appeared outside this ROI were tallied, in the original and all re-registered studies. Maximum displacements in X/Y position between images of studies registered by the LLI and Rl methods were also computed to directly compare positional accuracy. Stomachs partially exceeded the limits of the ROI in 27, 9, 53 and 54 frames (total of 710) in the original, LLI, Rl and Ll studies respectively. There were 4, 1, 6 and 7 studies with misregistered stomachs on more than 2 frames. Frames in seven Rl studies differed from the LLI studies in ) X/Y position by 3 pixels or more. Cross-correlation using LLI was the only method which improved upon the original manual registration. The Rl and Ll methods increased the number of misregistered frames. We conclude that in gastric emptying studies, as in biliary studies, object tracking by CC of LLI is the method of choice for image registration

  20. Behaviors study of image registration algorithms in image guided radiation therapy

    International Nuclear Information System (INIS)

    Zou Lian; Hou Qing

    2008-01-01

    Objective: Study the behaviors of image registration algorithms, and analyze the elements which influence the performance of image registrations. Methods: Pre-known corresponding coordinates were appointed for reference image and moving image, and then the influence of region of interest (ROI) selection, transformation function initial parameters and coupled parameter spaces on registration results were studied with a software platform developed in home. Results: Region of interest selection had a manifest influence on registration performance. An improperly chosen ROI resulted in a bad registration. Transformation function initial parameters selection based on pre-known information could improve the accuracy of image registration. Coupled parameter spaces would enhance the dependence of image registration algorithm on ROI selection. Conclusions: It is necessary for clinic IGRT to obtain a ROI selection strategy (depending on specific commercial software) correlated to tumor sites. Three suggestions for image registration technique developers are automatic selection of the initial parameters of transformation function based on pre-known information, developing specific image registration algorithm for specific image feature, and assembling real-time image registration algorithms according to tumor sites selected by software user. (authors)

  1. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  2. A functional magnetic resonance imaging study

    Indian Academy of Sciences (India)

    MADU

    systems and ultra fast imaging techniques, such as echo planar imaging (EPI ) ... is used to understand brain organization, assessing of neurological status, and ..... J C 1998 Functional MRI studies of motor recovery after stroke;. NeuroImage 7 ...

  3. Analysis of the performance and usefulness of a new digital gamma camera and short-lived radionuclide Au-195m for cardiac studies

    International Nuclear Information System (INIS)

    Mena, I.; Amaral, H.; Adams, R.; Garcia, E.; de Jong, R.

    1983-01-01

    The purpose of this investigation is to evaluate at LAC Harbor-UCLA Medical Center dead time characteristics of the digital camera Elscint (Apex 415), designed by the manufacturer to improve the count rate performance, its resolution and clinical applications in first pass ventriculography. The Hg-195m/Au-195m generator is evaluated for Hg-195 leakage, dosimetry and clinical usefulness. The high count rate capability of the digital camera is maximally utilized in biplane ventriculography which may become the optimal modality for dynamic cardiovascular nuclear medicine studies. The resolution achieved in this high count rate modality appears perfectly adequate for high quality studies. The imaging and radiation exposure characteristics of the 30.5 sec half life Au 195m are promising of a significant clinical contribution in the field of adult and pediatric cardiology

  4. PACS war room for global teleradiology

    Science.gov (United States)

    Chen, Doris T.; Ho, Bruce K. T.; Chao, Woodrew; Taira, Ricky K.; Kangarloo, Hooshang

    1995-05-01

    UCLA is beginning teleradiology projects in Latin America, Asian Pacific, and the U.S. The UCLA teleradiology system communicates with remote imaging centers through a T1 based WAN and satellite technology. A network management center, i.e., PACS war room, with graphical user interface allows the system manager to monitor and control different elements of the system through various levels of abstraction from one location. The network manager software can monitor the activities of both hardware and software devices in the remote imaging centers, LAN and WAN performance, telearchiving and teleaccess pattern. Telearchiving can be monitored by graphically indicating large image movements between jukeboxes and over LAN or WAN. Once the teleradiology system is configured, the image flow pattern in a teleradiology center is predictable. Manual intervention of these teleradiology system functions is easily done through menu control in the war room display. A centralized network management with the global view of a teleradiology system has been developed. It can give commands to the elements of the system to tune the system for efficient utilization of the system resources. These managerial functions scale with the teleradiology system which is expandable to include many more potential remote imaging centers.

  5. DENTAL CAST STUDY OF ADULT PATIENTS WITH UNTREATED UNILATERAL CLEFT-LIP OR CLEFT-LIP AND PALATE IN INDONESIA COMPARED WITH SURGICALLY TREATED PATIENTS IN THE NETHERLANDS

    NARCIS (Netherlands)

    SPAUWEN, PHM; HARDJOWASITO, W; BOERSMA, J; LATIEF, BS

    To determine differences in maxillary and dentoalveolar relationships between untreated and treated patients having unilateral clefts of the lip and alveolus (UCLA) or lip and palate (UCLP), dental cast assessments were done on 70 untreated adult Indonesian patients (UCLA-I, UCLP-I) and 67 Dutch

  6. Quality of life and psychosocial aspects in Greek patients with psoriasis: a cross-sectional study.

    Science.gov (United States)

    Kouris, Anargyros; Christodoulou, Christos; Stefanaki, Christina; Livaditis, Miltiadis; Tsatovidou, Revekka; Kouskoukis, Constantinos; Petridis, Athanasios; Kontochristopoulos, George

    2015-01-01

    Psoriasis is a common, long-term skin disease associated with high levels of psychological distress and a considerable adverse impact on life. The effects of psoriasis, beyond skin affliction, are seldom recognized and often undertreated. The aim of the study is to evaluate the quality of life, anxiety and depression, self-esteem and loneliness in patients with psoriasis. Eighty-four patients with psoriasis were enrolled in the study. The quality of life, depression and anxiety, loneliness and self-esteem of the patient were assessed using the Dermatology Life Quality Index, Hospital Anxiety and Depression Scale, the UCLA loneliness Scale (UCLA-Version 3) and Rosenberg's Self-esteem Scale, respectively. The Dermatology Quality of Life Index score among psoriasis patients was 12.61 ± 4.88. They had statistically significantly higher scores according to the Hospital Anxiety and Depression Scale -anxiety subscale (p=0.032)-compared with healthy volunteers. Moreover, a statistically significant difference was found between the two groups concerning the UCLA-scale (p=0.033) and RSES-scale (pself-esteem than male patients. Psoriasis is a distressing, recurrent disorder that significantly impairs quality of life. Therefore, the recognition and future management of psoriasis may require the involvement of multi-disciplinary teams to manage the physical, psychological and social aspects of the condition, as is the case for systemic, long-term conditions.

  7. STRUCTURAL BIOLOGY AND MOLECULAR MEDICINE RESEARCH PROGRAM (LSBMM)

    International Nuclear Information System (INIS)

    Eisenberg, David S.

    2008-01-01

    The UCLA-DOE Institute of Genomics and Proteomics is an organized research unit of the University of California, sponsored by the Department of Energy through the mechanism of a Cooperative Agreement. Today the Institute consists of 10 Principal Investigators and 7 Associate Members, developing and applying technologies to promote the biological and environmental missions of the Department of Energy, and 5 Core Technology Centers to sustain this work. The focus is on understanding genomes, pathways and molecular machines in organisms of interest to DOE, with special emphasis on developing enabling technologies. Since it was founded in 1947, the UCLA-DOE Institute has adapted its mission to the research needs of DOE and its progenitor agencies as these research needs have changed. The Institute started as the AEC Laboratory of Nuclear Medicine, directed by Stafford Warren, who later became the founding Dean of the UCLA School of Medicine. In this sense, the entire UCLA medical center grew out of the precursor of our Institute. In 1963, the mission of the Institute was expanded into environmental studies by Director Ray Lunt. I became the third director in 1993, and in close consultation with David Galas and John Wooley of DOE, shifted the mission of the Institute towards genomics and proteomics. Since 1993, the Principal Investigators and Core Technology Centers are entirely new, and the Institute has separated from its former division concerned with PET imaging. The UCLA-DOE Institute shares the space of Boyer Hall with the Molecular Biology Institute, and assumes responsibility for the operation of the main core facilities. Fig. 1 gives the organizational chart of the Institute. Some of the benefits to the public of research carried out at the UCLA-DOE Institute include the following: The development of publicly accessible, web-based databases, including the Database of Protein Interactions, and the ProLinks database of genomicly inferred protein function linkages

  8. Imaging study on acupuncture points

    Science.gov (United States)

    Yan, X. H.; Zhang, X. Y.; Liu, C. L.; Dang, R. S.; Ando, M.; Sugiyama, H.; Chen, H. S.; Ding, G. H.

    2009-09-01

    The topographic structures of acupuncture points were investigated by using the synchrotron radiation based Dark Field Image (DFI) method. Four following acupuncture points were studied: Sanyinjiao, Neiguan, Zusanli and Tianshu. We have found that at acupuncture point regions there exists the accumulation of micro-vessels. The images taken in the surrounding tissue out of the acupuncture points do not show such kind of structure. It is the first time to reveal directly the specific structure of acupuncture points by X-ray imaging.

  9. Imaging study on acupuncture points

    International Nuclear Information System (INIS)

    Yan, X H; Zhang, X Y; Liu, C L; Dang, R S; Ando, M; Sugiyama, H; Chen, H S; Ding, G H

    2009-01-01

    The topographic structures of acupuncture points were investigated by using the synchrotron radiation based Dark Field Image (DFI) method. Four following acupuncture points were studied: Sanyinjiao, Neiguan, Zusanli and Tianshu. We have found that at acupuncture point regions there exists the accumulation of micro-vessels. The images taken in the surrounding tissue out of the acupuncture points do not show such kind of structure. It is the first time to reveal directly the specific structure of acupuncture points by X-ray imaging.

  10. Display of nuclear medicine imaging studies

    International Nuclear Information System (INIS)

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Nuclear medicine imaging studies involve evaluation of a large amount of image data. Digital signal processing techniques have introduced processing algorithms that increase the information content of the display. Nuclear medicine imaging studies require interactive selection of suitable form of display and pre-display processing. Static imaging study requires pre-display processing to detect focal defects. Point operations (histogram modification) along with zoom and capability to display more than one image in one screen is essential. This album mode of display is also applicable to dynamic, MUGA and SPECT data. Isometric display or 3-D graph of the image data is helpful in some cases e.g. point spread function, flood field data. Cine display is used on a sequence of images e.g. dynamic, MUGA and SPECT imaging studies -to assess the spatial movement of tracer with time. Following methods are used at the investigator's discretion for inspection of the 3-D object. 1) Display of orthogonal projections, 2) Display of album of user selected coronal/ sagital/ transverse orthogonal slices, 3) Display of three orthogonal slices through user selected point, 4) Display of a set of orthogonal slices generated in the user-selected volume, 5) Generation and display of 3-D shaded surface. 6) Generation of volume data and display along with the 3-D shaded surface, 7) Side by side display orthogonal slices of two 3-D objects. Displaying a set of two-dimensional slices of a 3-D reconstructed object through shows all the defects but lacks the 3-D perspective. Display of shaded surface lacks the ability to show the embedded defects. Volume display -combining the 3-D surface and gray level volume data is perhaps the best form of display. This report describes these forms of display along with the theory. (author)

  11. Re-thinking the store image study approach

    DEFF Research Database (Denmark)

    Hansen, Kåre

    2001-01-01

    Store image has traditionally been of interest in the Western markets. Studies of store image have also assessed the image of one or a few competing stores. This paper develops an approach to capture store images of an entire retail sector, an issue of importance when enter-ing the new emerging...

  12. UCLA program in reactor studies: The ARIES tokamak reactor study

    International Nuclear Information System (INIS)

    1991-01-01

    The ARIES research program is a multi-institutional effort to develop several visions of tokamak reactors with enhanced economic, safety, and environmental features. The aims are to determine the potential economics, safety, and environmental features of a range of possible tokamak reactors, and to identify physics and technology areas with the highest leverage for achieving the best tokamak reactor. Four ARIES visions are currently planned for the ARIES program. The ARIES-1 design is a DT-burning reactor based on ''modest'' extrapolations from the present tokamak physics database and relies on either existing technology or technology for which trends are already in place, often in programs outside fusion. ARIES-2 and ARIES-4 are DT-burning reactors which will employ potential advances in physics. The ARIES-2 and ARIES-4 designs employ the same plasma core but have two distinct fusion power core designs; ARIES-2 utilize the lithium as the coolant and breeder and vanadium alloys as the structural material while ARIES-4 utilizes helium is the coolant, solid tritium breeders, and SiC composite as the structural material. Lastly, the ARIES-3 is a conceptual D- 3 He reactor. During the period Dec. 1, 1990 to Nov. 31, 1991, most of the ARIES activity has been directed toward completing the technical work for the ARIES-3 design and documenting the results and findings. We have also completed the documentation for the ARIES-1 design and presented the results in various meetings and conferences. During the last quarter, we have initiated the scoping phase for ARIES-2 and ARIES-4 designs

  13. Quality of life psychosocial characteristics in Greek patients with leg ulcers: a case control study.

    Science.gov (United States)

    Kouris, Anargyros; Armyra, Kalliopi; Christodoulou, Christos; Sgontzou, Themis; Karypidis, Dimitrios; Kontochristopoulos, George; Liordou, Fotini; Zakopoulou, Nikoletta; Zouridaki, Eftychia

    2016-10-01

    Chronic leg ulcers are a public health problem that can have a significant impact on the patient's physical, socioeconomic and psychological status. The aim of this study is to evaluate the quality of life, anxiety and depression, self-esteem and loneliness in patients suffering from leg ulcers. A total of 102 patients were enrolled in the study. The quality of life, anxiety and depression, self-esteem and loneliness of the patient were assessed using the Dermatology Life Quality Index (DLQI), Hospital Anxiety and Depression Scale (HADS), Rosenberg's Self-esteem Scale (RSES) and the UCLA Loneliness Scale (UCLA-Version 3), respectively. The mean DLQI score was 13·38 ± 2·59, suggesting a serious effect on the quality of life of patients. Those with leg ulcers had statistically significant higher scores according to the HADS-total scale (P = 0·031) and HADS-anxiety subscale (P = 0·015) compared with healthy volunteers. Moreover, a statistically significant difference was found between the two groups concerning the UCLA-scale (P = 0·029). Female patients presented with a higher score of anxiety (P = 0·027) and social isolation (P = 0·048), and worse quality of life (P = 0·018) than male patients. A severe quality of life impairment was documented, reflecting a significant psychosocial impact on patients with leg ulcers. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  14. Microwave Imaging of Human Forearms: Pilot Study and Image Enhancement

    Directory of Open Access Journals (Sweden)

    Colin Gilmore

    2013-01-01

    Full Text Available We present a pilot study using a microwave tomography system in which we image the forearms of 5 adult male and female volunteers between the ages of 30 and 48. Microwave scattering data were collected at 0.8 to 1.2 GHz with 24 transmitting and receiving antennas located in a matching fluid of deionized water and table salt. Inversion of the microwave data was performed with a balanced version of the multiplicative-regularized contrast source inversion algorithm formulated using the finite-element method (FEM-CSI. T1-weighted MRI images of each volunteer’s forearm were also collected in the same plane as the microwave scattering experiment. Initial “blind” imaging results from the utilized inversion algorithm show that the image quality is dependent on the thickness of the arm’s peripheral adipose tissue layer; thicker layers of adipose tissue lead to poorer overall image quality. Due to the exible nature of the FEM-CSI algorithm used, prior information can be readily incorporated into the microwave imaging inversion process. We show that by introducing prior information into the FEM-CSI algorithm the internal anatomical features of all the arms are resolved, significantly improving the images. The prior information was estimated manually from the blind inversions using an ad hoc procedure.

  15. A game-based platform for crowd-sourcing biomedical image diagnosis and standardized remote training and education of diagnosticians

    Science.gov (United States)

    Feng, Steve; Woo, Minjae; Chandramouli, Krithika; Ozcan, Aydogan

    2015-03-01

    Over the past decade, crowd-sourcing complex image analysis tasks to a human crowd has emerged as an alternative to energy-inefficient and difficult-to-implement computational approaches. Following this trend, we have developed a mathematical framework for statistically combining human crowd-sourcing of biomedical image analysis and diagnosis through games. Using a web-based smart game (BioGames), we demonstrated this platform's effectiveness for telediagnosis of malaria from microscopic images of individual red blood cells (RBCs). After public release in early 2012 (http://biogames.ee.ucla.edu), more than 3000 gamers (experts and non-experts) used this BioGames platform to diagnose over 2800 distinct RBC images, marking them as positive (infected) or negative (non-infected). Furthermore, we asked expert diagnosticians to tag the same set of cells with labels of positive, negative, or questionable (insufficient information for a reliable diagnosis) and statistically combined their decisions to generate a gold standard malaria image library. Our framework utilized minimally trained gamers' diagnoses to generate a set of statistical labels with an accuracy that is within 98% of our gold standard image library, demonstrating the "wisdom of the crowd". Using the same image library, we have recently launched a web-based malaria training and educational game allowing diagnosticians to compare their performance with their peers. After diagnosing a set of ~500 cells per game, diagnosticians can compare their quantified scores against a leaderboard and view their misdiagnosed cells. Using this platform, we aim to expand our gold standard library with new RBC images and provide a quantified digital tool for measuring and improving diagnostician training globally.

  16. Reevaluation of JPEG image compression to digitalized gastrointestinal endoscopic color images: a pilot study

    Science.gov (United States)

    Kim, Christopher Y.

    1999-05-01

    Endoscopic images p lay an important role in describing many gastrointestinal (GI) disorders. The field of radiology has been on the leading edge of creating, archiving and transmitting digital images. With the advent of digital videoendoscopy, endoscopists now have the ability to generate images for storage and transmission. X-rays can be compressed 30-40X without appreciable decline in quality. We reported results of a pilot study using JPEG compression of 24-bit color endoscopic images. For that study, the result indicated that adequate compression ratios vary according to the lesion and that images could be compressed to between 31- and 99-fold smaller than the original size without an appreciable decline in quality. The purpose of this study was to expand upon the methodology of the previous sty with an eye towards application for the WWW, a medium which would expand both clinical and educational purposes of color medical imags. The results indicate that endoscopists are able to tolerate very significant compression of endoscopic images without loss of clinical image quality. This finding suggests that even 1 MB color images can be compressed to well under 30KB, which is considered a maximal tolerable image size for downloading on the WWW.

  17. Establishment study of the in vivo imaging analysis with small animal imaging modalities for bio-durg development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Choi, Dae Seong; Park, Jeonghoon; Jung, Uhee; Lee, Yun Jong

    2012-01-01

    In this study, we established the image modalities (micro-PET, SPECT/CT) using the experimental animal (mouse) for the development of imaging assessment method for the bio-durg and extramural collaboration proposal. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc tricarbonyl bifunctional chelators and 18 F-clotrimazole derivative. SPECT imaging studies were performed with 99m Tc tricarbonyl BFCs. PET imaging study was performed with 18 F-clotrimazole derivatives. We performed the PET image study of 18 F-clotrimazole derivatives using U87MG tumor bearing mice. Also we tested the intramural and extramural collaboration using small animal imaging modalities and prepared the draft of extramural R and D operation manual for small animal imaging modalities and the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  18. Automated image registration for FDOPA PET studies

    International Nuclear Information System (INIS)

    Kang-Ping Lin; Sung-Cheng Huang, Dan-Chu Yu; Melega, W.; Barrio, J.R.; Phelps, M.E.

    1996-01-01

    In this study, various image registration methods are investigated for their suitability for registration of L-6-[18F]-fluoro-DOPA (FDOPA) PET images. Five different optimization criteria including sum of absolute difference (SAD), mean square difference (MSD), cross-correlation coefficient (CC), standard deviation of pixel ratio (SDPR), and stochastic sign change (SSC) were implemented and Powell's algorithm was used to optimize the criteria. The optimization criteria were calculated either unidirectionally (i.e. only evaluating the criteria for comparing the resliced image 1 with the original image 2) or bidirectionally (i.e. averaging the criteria for comparing the resliced image 1 with the original image 2 and those for the sliced image 2 with the original image 1). Monkey FDOPA images taken at various known orientations were used to evaluate the accuracy of different methods. A set of human FDOPA dynamic images was used to investigate the ability of the methods for correcting subject movement. It was found that a large improvement in performance resulted when bidirectional rather than unidirectional criteria were used. Overall, the SAD, MSD and SDPR methods were found to be comparable in performance and were suitable for registering FDOPA images. The MSD method gave more adequate results for frame-to-frame image registration for correcting subject movement during a dynamic FDOPA study. The utility of the registration method is further demonstrated by registering FDOPA images in monkeys before and after amphetamine injection to reveal more clearly the changes in spatial distribution of FDOPA due to the drug intervention. (author)

  19. Recent lung imaging studies

    International Nuclear Information System (INIS)

    Taplin, G.V.; Chopra, S.K.

    1976-01-01

    Radionuclide lung imaging procedures have been available for 11 years but only the perfusion examination has been used extensively and mainly for the diagnosis of pulmonary embolism (P.E.). Its ability to reveal localized ischemia makes it a valuable test of regional lung function as well as a useful diagnostic aid in P.E. Although it had been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing P.E. from COPD. In this review emphasis is placed on our recent experience with both of these inhalation procedures in comparison with pulmonary function tests and roentgenography for the early detection of COPD in population studies. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging for a functional diagnosis of P.E. Two new developments in regional lung diffusion imaging, performed after the inhalation of radioactive gases and/or rapidly absorbed radioaerosols are described. The experimental basis for their potential clinical application in pulmonary embolism detection is presented

  20. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  1. Brain imaging studies of sleep disorder

    International Nuclear Information System (INIS)

    Nakamura, Masaki; Inoue, Yuichi

    2014-01-01

    Brain imaging studies of narcolepsy (NA)/cataplexy (CA), a typical sleep disorder, are summarized together with techniques of functional and structural imaging means. single photon emission CT (SPECT) is based on the distribution of tracers labeled by single photon emitters like 99m Tc and 123 I for seeing the blood flow and receptors. PET using positron emitters like 15 O and 18 F for blood flow and for glucose metabolism, respectively, is of higher resolution and more quantitative than SPECT. Functional MRI (fMRI) depicts the cerebral activity through signal difference by blood oxygenation level dependence (BOLD) effect, and MR spectroscopy (MRS) depicts and quantifies biomaterials through the difference of their nuclear chemical shifts in the magnetic field. Morphologic imaging studies involve the measurement of the volume of the region of interest by comparison with the reference region such as the whole brain volume. Voxel-based morphometry (VBM) has changed to its more advanced surface-based analysis (SBA) of T1-enhanced image. Diffusion tensor imaging (DTI) is based on the tissue water diffusion. Functional SPECT/PET studies have suggested the decrease of blood flow and metabolic activity in the hypothalamus (HT) and other related regions at the conscious resting state, and locally increased blood flow in cingulate gyrus (CG) and amygdaloid complex (AC) at affective CA/PA seizure. fMRI has suggested the hypoactivity of HT and hyperactivity of AC at the seizure. VBM-based studies have not given the consistent results, but DTI studies have suggested an important participation of AC at the seizure. (T.T.)

  2. Evaluation of the Satisfaction with Appearance Scale and Its Short Form in Systemic Sclerosis: Analysis from the UCLA Scleroderma Quality of Life Study.

    Science.gov (United States)

    Mills, Sarah D; Fox, Rina S; Merz, Erin L; Clements, Philip J; Kafaja, Suzanne; Malcarne, Vanessa L; Furst, Daniel E; Khanna, Dinesh

    2015-09-01

    Changes in appearance are common in patients with systemic sclerosis (SSc) and can significantly affect well-being. The Satisfaction with Appearance Scale (SWAP) measures body image dissatisfaction in persons with visible disfigurement; the Brief-Satisfaction with Appearance Scale (Brief-SWAP) is its short form. The present study evaluated the reliability and validity of SWAP and Brief-SWAP scores in SSc. A sample of 207 patients with SSc participating in the University of California, Los Angeles Scleroderma Quality of Life Study completed the SWAP. Brief-SWAP scores were derived from the SWAP. The structural validity of both measures was investigated using confirmatory factor analysis. Internal consistency reliability of total and subscale scores was assessed with Cronbach's alpha coefficients. Convergent and divergent validity was evaluated using the Center for Epidemiological Studies Depression Scale, the Health Assessment Questionnaire-Disability Index, and the Medical Outcomes Study Short Form-36 questionnaire. SWAP and Brief-SWAP total scores were highly correlated (r = 0.97). The 4-factor structure of the SWAP fit well descriptively; the 2-factor structure of the Brief-SWAP fit well descriptively and statistically. Internal consistencies for total and subscale scores were good, and results supported convergent and divergent validity. Both versions are suitable for use in patients with SSc. The Brief-SWAP is most efficient; the full SWAP yields additional subscales that may be informative in understanding body image issues in patients with SSc.

  3. Adding attenuation corrected images in myocardial perfusion imaging reduces the need for a rest study

    International Nuclear Information System (INIS)

    Trägårdh, Elin; Valind, Sven; Edenbrandt, Lars

    2013-01-01

    The American Society of Nuclear Cardiology and the Society of Nuclear Medicine conclude that incorporation of attenuation corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve diagnostic accuracy. The aim was to investigate the value of adding AC stress-only images for the decision whether a rest study is necessary or not. 1,261 patients admitted to 99m Tc MPS were studied. The stress studies were interpreted by two physicians who judged each study as “no rest study necessary” or “rest study necessary”, by evaluating NC stress-only and NC + AC stress-only images. When there was disagreement between the two physicians, a third physician evaluated the studies. Thus, agreement between 2 out of 3 physicians was evaluated. The physicians assessed 214 more NC + AC images than NC images as “no rest study necessary” (17% of the study population). The number of no-rest-study-required was significantly higher for NC + AC studies compared to NC studies (859 vs 645 cases (p < 0.0001). In the final report according to clinical routine, ischemia or infarction was reported in 23 patients, assessed as “no rest study necessary” (22 NC + AC cases; 8 NC cases), (no statistically significant difference). In 11 of these, the final report stated “suspected/possible ischemia or infarction in a small area”. Adding AC stress-only images to NC stress-only images reduce the number of unnecessary rest studies substantially

  4. Multimodality Imaging Probe for Positron Emission Tomography and Fluorescence Imaging Studies

    Directory of Open Access Journals (Sweden)

    Suresh K. Pandey

    2014-05-01

    Full Text Available Our goal is to develop multimodality imaging agents for use in cell tracking studies by positron emission tomography (PET and optical imaging (OI. For this purpose, bovine serum albumin (BSA was complexed with biotin (histologic studies, 5(6- carboxyfluorescein, succinimidyl ester (FAM SE (OI studies, and diethylenetriamine pentaacetic acid (DTPA for chelating gallium 68 (PET studies. For synthesis of BSA-biotin-FAM-DTPA, BSA was coupled to (+-biotin N-hydroxysuccinimide ester (biotin-NHSI. BSA- biotin was treated with DTPA-anhydride and biotin-BSA-DTPA was reacted with FAM. The biotin-BSA-DTPA-FAM was reacted with gallium chloride 3 to 5 mCi eluted from the generator using 0.1 N HCl and was passed through basic resin (AG 11 A8 and 150 mCi (100 μL, pH 7–8 was incubated with 0.1 mg of FAM conjugate (100 μL at room temperature for 15 minutes to give 66Ga-BSA-biotin-DTPA-FAM. A shaved C57 black mouse was injected with FAM conjugate (50 μL at one flank and FAM-68Ga (50 μL, 30 mCi at the other. Immediately after injection, the mouse was placed in a fluorescence imaging system (Kodak In-Vivo F, Bruker Biospin Co., Woodbridge, CT and imaged (Λex: 465 nm, Λem: 535 nm, time: 8 seconds, Xenon Light Source, Kodak. The same mouse was then placed under an Inveon microPET scanner (Siemens Medical Solutions, Knoxville, TN injected (intravenously with 25 μCi of 18F and after a half-hour (to allow sufficient bone uptake was imaged for 30 minutes. Molecular weight determined using matrix-associated laser desorption ionization (MALDI for the BSA sample was 66,485 Da and for biotin-BSA was 67,116 Da, indicating two biotin moieties per BSA molecule; for biotin-BSA-DTPA was 81,584 Da, indicating an average of 30 DTPA moieties per BSA molecule; and for FAM conjugate was 82,383 Da, indicating an average of 1.7 fluorescent moieties per BSA molecule. Fluorescence imaging clearly showed localization of FAM conjugate and FAM-68Ga at respective flanks of the mouse

  5. A Cognitive Semiotic Study of Students' Reading a Textless Image versus a Verbal Image

    Directory of Open Access Journals (Sweden)

    Roaa Hasan Ali

    2016-10-01

    Full Text Available This study explores fourth year college students'   content   retrieval from reading textless versus verbal images. Furthermore, it examines  the extent to which the respondents comprehend and understand them .The procedures include selecting an image from the internet, designing a written test with its rubrics and exposing it to jury members to ascertain its face validity. The data of this study were analyzed according to the adopted of Peirce's model (1931 of ' icon, index and symbol'. The researchers find out that most of the results were in favor of the verbal images, captions restrict readers' creativity to infer any additional message. Keywords: Content retrieval, Textless images, Verbal images

  6. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  7. Neuromyelitis optica: a diffusional kurtosis imaging study.

    Science.gov (United States)

    Doring, T M; Lopes, F C R; Kubo, T T A; Tukamoto, G; Kimura, M C; Strecker, R M; Domingues, R C; Gasparetto, E L

    2014-12-01

    Conventional MR imaging typically yields normal images of the brain or indicates lesions in areas of high aquaporin expression in patients with neuromyelitis optica. Diffusional kurtosis imaging was applied in patients with neuromyelitis optica to determine whether this technique could detect alterations in diffusion and diffusional kurtosis parameters in normal-appearing white matter and to explore the relationship between diffusional kurtosis imaging and DTI parameters. Thirteen patients with neuromyelitis optica and 13 healthy controls underwent MR imaging of the brain with conventional and diffusional kurtosis imaging sequences. Tract-based spatial statistics and region-of-interest-based analyses were conducted to identify differences between patients with neuromyelitis optica and controls through conventional DTI and diffusional kurtosis imaging parameters. The parameters were correlated to determine the potential relationship between them. Compared with healthy controls, several diffusional kurtosis imaging and DTI parameters were altered in various fiber tracts of patients with neuromyelitis optica (P optica. We found a negative correlation between diffusional kurtosis imaging (radial kurtosis, axial kurtosis, mean kurtosis) and the corresponding DTI parameters (radial diffusivity, axial diffusivity, mean diffusivity). Positive correlations were found for radial kurtosis and mean kurtosis with fractional anisotropy. This study demonstrated differences in conventional diffusion and diffusional kurtosis parameters, especially radial kurtosis, in the normal-appearing white matter of patients with neuromyelitis optica compared with healthy controls. Larger studies of patients with neuromyelitis optica should be performed to assess the potential clinical impact of these findings. © 2014 by American Journal of Neuroradiology.

  8. Does an Injection of Adipose-Derived Mesenchymal Stem Cells Loaded in Fibrin Glue Influence Rotator Cuff Repair Outcomes? A Clinical and Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Kim, Yong Sang; Sung, Chang Hun; Chung, Sung Hoon; Kwak, Sang Joon; Koh, Yong Gon

    2017-07-01

    The mesenchymal stem cell (MSC)-based tissue engineering approach has been developed to improve the treatment of rotator cuff tears. Hypothesis/Purpose: The purpose was to determine the effect of an injection of adipose-derived MSCs loaded in fibrin glue during arthroscopic rotator cuff repair on clinical outcomes and to evaluate its effect on structural integrity using magnetic resonance imaging (MRI). The hypothesis was that the application of adipose-derived MSCs would improve outcomes after the surgical repair of a rotator cuff tear. Cohort study; Level of evidence, 3. Among 182 patients treated with arthroscopic surgery for a rotator cuff tear, 35 patients treated with arthroscopic rotator cuff repair alone (conventional group) were matched with 35 patients who underwent arthroscopic rotator cuff repair with an injection of adipose-derived MSCs loaded in fibrin glue (injection group) based on sex, age, and lesion size. Outcomes were assessed with respect to the visual analog scale (VAS) for pain, range of motion (ROM) (including forward flexion, external rotation at the side, and internal rotation at the back), and functional measures of the Constant score and University of California, Los Angeles (UCLA) shoulder rating scale. Repaired tendon structural integrity was assessed by using MRI at a minimum of 12 months after surgery, and the mean clinical follow-up was 28.8 ± 4.2 months in the conventional group and 28.3 ± 3.8 months in the injection group. The mean VAS score at rest and during motion improved significantly in both groups after surgery. However, there were no significant differences between the groups at the final follow-up ( P = .256 and .776, respectively). Compared with preoperative measurements, forward flexion and external rotation at the side significantly improved at the final follow-up in both groups (all P rotation at the back were observed in either group ( P = .625 and .834 for the conventional and injection groups, respectively

  9. Role of chelates in magnetic resonance imaging studies

    Directory of Open Access Journals (Sweden)

    Tripathi Laxmi

    2009-01-01

    Full Text Available Imaging studies are tests performed with a variety of techniques that produce pictures of the inside of a patient′s body. Magnetic resonance imaging (MRI is an imaging technique based on the principles of nuclear magnetic resonance. MRI uses a powerful magnetic field, radio waves, and a computer to produce detailed pictures of organs, soft tissues, bone, and virtually all other internal body structures. Chelates have a wide application in such imaging techniques. Chelates in imaging studies are used alone as radioactive agents or conjugated to monoclonal antibodies or to DNA as radioactive agents. Technetium chelates and gadolinium chelates are being widely used as magnetic resonance contrast media.

  10. Radiation-Induced Immune Modulation in Prostate Cancer

    Science.gov (United States)

    2008-01-01

    Toxicology Program, Riverside, CA Invited Seminar: “The Proteasome as a Sensor of Stress” 3/17/04 McBride, W.H., UCLA Department of Dentistry Monthly...McBride1 1Radiation Oncology at UCLA, 2Surgical Oncology at UCLA, 3Pathology & Laboratory Medicine at UCLA, 4Public Health Biostatistics

  11. Study of Three-Dimensional Image Brightness Loss in Stereoscopy

    Directory of Open Access Journals (Sweden)

    Hsing-Cheng Yu

    2015-10-01

    Full Text Available When viewing three-dimensional (3D images, whether in cinemas or on stereoscopic televisions, viewers experience the same problem of image brightness loss. This study aims to investigate image brightness loss in 3D displays, with the primary aim being to quantify the image brightness degradation in the 3D mode. A further aim is to determine the image brightness relationship to the corresponding two-dimensional (2D images in order to adjust the 3D-image brightness values. In addition, the photographic principle is used in this study to measure metering values by capturing 2D and 3D images on television screens. By analyzing these images with statistical product and service solutions (SPSS software, the image brightness values can be estimated using the statistical regression model, which can also indicate the impact of various environmental factors or hardware on the image brightness. In analysis of the experimental results, comparison of the image brightness between 2D and 3D images indicates 60.8% degradation in the 3D image brightness amplitude. The experimental values, from 52.4% to 69.2%, are within the 95% confidence interval

  12. Comparative study of ultrasound imaging, computed tomography and magnetic resonance imaging in gynecology

    International Nuclear Information System (INIS)

    Ishii, Kenji; Kobayashi, Hisaaki; Hoshihara, Takayuki; Kobayashi, Mitsunao; Suda, Yoshio; Takenaka, Eiichi; Sasa, Hidenori.

    1989-01-01

    We studied 18 patients who were operated at the National Defense Medical College Hospital and confirmed by pathological diagnosis. We compared ultrasound imaging, computed tomography (CT) and magnetic resonance imaging (MRI) of the patients. MRI was useful to diagnose enlargement of the uterine cavity and a small amount of ascites and to understand orientation of the pelvic organs. Ultrasound imaging is the most useful examination to diagnose gynecological diseases. But when it is difficult to diagnose by ultrasound imaging alone, we should employ either CT or MRI, or preferably both. (author)

  13. Affect Labeling: A Promising New Approach for Mitigating PTSD

    Science.gov (United States)

    2016-02-12

    effects and contraindications (Becker et al., 2004). Barriers associated with pharmacological treatments are equal if not greater and include resistance...0056 20 MRI scanning. (2) Ps must not have been claustrophobic in order to be able to complete all fMRI procedures. (3) Ps must not have been...aversive combat stimuli. Image Acquisition. Imaging data were acquired via a Siemens Tim Trio 3 tesla MRI scanner at the UCLA Staglin Center for

  14. CTR plasma engineering studies

    International Nuclear Information System (INIS)

    Miley, G.H.

    1990-01-01

    The main focus of the work by the Fusion Plasma Engineering Group at the University during the prior contract year involved a study of fusion ash (helium) effects on burn efficiency and on potential ways to control ash buildup. This work has wide application to a variety of fusion reactor concepts, but the immediate application for the present work is in the ARIES tokamak reactor design study now being undertaken by a national design team headed by the UCLA. The examples presented here largely deal with the ARIES-I design which is a D-T device operating in the first instability regime

  15. Study on Processing Method of Image Shadow

    Directory of Open Access Journals (Sweden)

    Wang Bo

    2014-07-01

    Full Text Available In order to effectively remove disturbance of shadow and enhance robustness of information processing of computer visual image, this paper makes study on inspection and removal of image shadow. It makes study the continual removal algorithm of shadow based on integration, the illumination surface and texture, it respectively introduces their work principles and realization method, it can effectively carrying processing for shadow by test.

  16. Outcome and Structural Integrity of Rotator Cuff after Arthroscopic Treatment of Large and Massive Tears with Double Row Technique: A 2-Year Followup

    Directory of Open Access Journals (Sweden)

    Ignacio Carbonel

    2013-01-01

    Full Text Available Purpose. The purpose of this study was to evaluate the functional outcome and the tendon healing after arthroscopic double row rotator cuff repair of large and massive rotator cuff tears. Methods. 82 patients with a full-thickness large and massive rotator cuff tear underwent arthroscopic repair with double row technique. Results were evaluated by use of the UCLA, ASES, and Constant questionnaires, the Shoulder Strength Index (SSI, and range of motion. Follow-up time was 2 years. Magnetic resonance imaging (MRI studies were performed on each shoulder preoperatively and 2 years after repair. Results. 100% of the patients were followed up. UCLA, ASES, and Constant questionnaires showed significant improvement compared with preoperatively (P<0.001. Range of motion and SSI in flexion, abduction, and internal and external rotation also showed significant improvement (P<0.001. MRI studies showed 24 cases of tear after repair (29%. Only 8 cases were a full-thickness tear. Conclusions. At two years of followup, in large and massive rotator cuff tears, an arthroscopic double row rotator cuff repair technique produces an excellent functional outcome and structural integrity.

  17. Acute stress among adolescents and female rape victims measured by ASC-Kids: a pilot study.

    Science.gov (United States)

    Nilsson, Doris; Nordenstam, Carin; Green, Sara; Wetterhall, Annika; Lundin, Tom; Svedin, Carl Göran

    2015-01-01

    Rape is considered a stressful trauma and often with durable consequences. How the aftermath of rape is for young adolescents' girls considering acute stress is an overlooked field and remains to be studied. In this study, we wanted to investigate acute stress among adolescent victims of rape and the psychometric properties of the Acute Stress Checklist for Children (ASC-Kids). A clinical sample (n = 79) of raped girls, 13-17 years old who had turned to a special rape victim unit for treatment, answered the ASC-Kids. ASC-Kids was also given to a group of minor stressed, non-raped adolescents in the same age range (n = 154) together with the University of California at Los Angeles Post-traumatic Stress Disorder Reaction Index (UCLA PTSD RI), and the Sense of Coherence Scale 13 (SOC-13). The scores from the groups were compared and showed significant differences in mean values on all the diagnostic criteria of acute stress disorder. In the clinical group, 36.7% obtained full ASD criteria. ASC-Kids could discriminate well between groups. Cronbach's alpha was found to be excellent, and the correlation between the UCLA PTSD RI and ASC-Kids found to be good; both ASC-Kids and UCLA PTSD RI had a good and moderate negative correlation with SOC-13. Adolescent female rape victims were shown to have a very high level of acute stress, and the ASC-Kids was found to have sound psychometrics and can be a valuable screening instrument to support clinicians in their assessments of an indication of adolescents after potentially stressful events such as rape.

  18. Institutional solid waste management practices in developing countries. A case study of three academic institutions in Tanzania

    Energy Technology Data Exchange (ETDEWEB)

    Mbuligwe, Stephen E. [Faculty of Lands and Environmental Engineering, Department of Environmental Engineering, University College of Lands and Architectural Studies UCLAS, PO Box 35176, Dar es Salaam (Tanzania, United Republic of)

    2002-05-01

    This paper reports on institutional solid waste management in three Tanzanian institutions. It is noted that there are indeed advantages in managing solid waste at institutional level because of the institutions' unique characteristics that also influence their waste management needs. The paper outlines findings from a yearlong study on institutional solid waste management at three institutions: University of Dar es Salaam (UDSM), University College of Lands and Architectural Studies (UCLAS) and Water Resources Institute (WRI). Surveys and field investigations, including on-site waste measurements and questionnaire surveys were done at UDSM, UCLAS and WRI. The study has revealed, among other things, that per capita waste generation rates, W{sub G} vary between staff and students within each institution as well as among the three institutions. The composition of the waste was found to be predominantly organic in nature, suggesting a strong resource recovery potential in terms of animal feed or production of biogas through anaerobic digestion. Additionally, the W{sub G} was found to vary in line with changes in institutional activities like normal studies, examinations and holidays. The study has shown that resource recovery could greatly enhance solid waste management at the case study institutions.

  19. Image processing of angiograms: A pilot study

    Science.gov (United States)

    Larsen, L. E.; Evans, R. A.; Roehm, J. O., Jr.

    1974-01-01

    The technology transfer application this report describes is the result of a pilot study of image-processing methods applied to the image enhancement, coding, and analysis of arteriograms. Angiography is a subspecialty of radiology that employs the introduction of media with high X-ray absorption into arteries in order to study vessel pathology as well as to infer disease of the organs supplied by the vessel in question.

  20. FAIR imaging of the liver. A preliminary study

    International Nuclear Information System (INIS)

    Kiryu, Shigeru; Machida, Toru; Noda, Masanobu

    1998-01-01

    Flow-sensitive alternating inversion recovery (FAIR) technique has recently been introduced for perfusion or functional MR studies of the brain. In the imaging of liver neoplasms, the evaluation of tumor vascularity is important for diagnosis, and therefore the FAIR technique may potentially complement liver MR imaging. The purpose of this study was to evaluate the usefulness of a FAIR sequence in MR imaging of the liver and to compare it with arterial-phase images of dynamic MR imaging. One volunteer and six patients with focal hepatic lesions (one with hepatocellular carcinoma (HCC), three with metastasis, and two with cavernous hemangioma) underwent FAIR. Short TI (600 ms) and long TI (1200 ms) images were obtained during breath-hold. In normal volunteers, the vessels generated remarkably bright signal in both short and long TI. Signal intensity of liver parenchyma was low in short TI, and became stronger in long TI. Two HCC (in one patient) (100%), one hemangioma (50%), and three metastases (100%) were well delineated as bright lesions. One HCC produced peripheral high intensity in short-TI FAIR image, and this finding was consistent with the result of dynamic MR study. Another HCC, which showed no clear enhancement in the arterial-phase dynamic MRI, was visualized only in long-TI FAIR. One hemangioma, which was clearly seen in FAIR image, showed rapid and strong enhancement on dynamic MRI. It is concluded that FAIR is a promising technique for evaluation of vascularity of hepatic tumors without using contrast materials. (author)

  1. Reflex sympathetic dystrophy syndrome: MR imaging study

    International Nuclear Information System (INIS)

    Masciocchi, C.; Fascetti, E.; Bonanni, G.; Calvisi, V.; Buoni, C.; Passariello, R.

    1987-01-01

    Reflex sympathetic dystrophy syndrome (RSDS) is characterized by pain, swelling, and limitation of motion. The etiology and pathophysiology mechanism have not yet been identified. We considered eight patients with clinical signs of RSDS, in five cases located at the knee joint and in three cases in the hip. In all cases conventional radiography and radionuclide bone scanning were performed before MR imaging. Conventional radiography was negative in three cases while scintigraphy demonstrated the lesion in all patients. MR imaging showed an area of low intensity signal on T1-weighted scans and an increased signal intensity on T2-weighted images. This area is located at the bone marrow and its regular and homogeneous. This specific finding on MR images is due to reflect edema by hyperemia of the bone marrow. The MR imaging diagnosis was confirmed on clinical and radiological follow-up. MR imaging can have a role in the differential diagnosis when other studies are nondiagnostic or nonspecific for RSDS

  2. An Exploratory Study of Residents’ Perception of Place Image

    Science.gov (United States)

    Stylidis, Dimitrios; Sit, Jason; Biran, Avital

    2014-01-01

    Studies on place image have predominantly focused on the tourists’ destination image and have given limited attention to other stakeholders’ perspectives. This study aims to address this gap by focusing on the notion of residents’ place image, whereby it reviews existing literature on residents’ place image in terms of whether common attributes can be identified, and examines the role of community-focused attributes in its measurement. Data collected from a sample of 481 Kavala residents (Greece) were subjected to exploratory and confirmatory factor analysis. The study reveals that the existing measurement tools have typically emphasized destination-focused attributes and neglected community-focused attributes. This study contributes to the residents’ place image research by proposing a more holistic measurement, which consisted of four dimensions: physical appearance, community services, social environment, and entertainment opportunities. The study also offers practical insights for developing and promoting a tourist place while simultaneously enhancing its residents’ quality of life. PMID:29708109

  3. Radiation: Rational use of diagnostic imaging studies in pediatrics

    International Nuclear Information System (INIS)

    Gentile, Fernando

    2008-01-01

    The objectives of this paper are to recognize the biological effects of radiation; explain the action of ionizing radiation on the cell; list the main sources of ionizing radiation; to indicate imaging studies considering the danger of radiation; select the method of imaging saving radiation; rational use of imaging studies without repeating exams. [es

  4. Análise comparativa do resultado da sutura artroscópica da lesão do manguito rotador em pacientes fumantes e não fumantes Comparative analysis on the result from arthroscopic suturing of rotator cuff injuries between smoking and non-smoking patients

    Directory of Open Access Journals (Sweden)

    Alexandre Almeida

    2011-04-01

    cuff injuries between smoking and non-smoking patients. METHODS: A group of 286 patients who underwent arthroscopic suturing of primary rotator cuff injuries between June 12, 2002, and May 14, 2008, was analyzed. The patients included in the study were evaluated using the UCLA scale, with a minimum follow-up of 12 months and average of 56.52 months. The variables studied were age, sex, side operated, dominance, profile of cigarette use and UCLA index. RESULTS: This study evaluated a total of 205 patients. Mean age (p = 0.289 and sex (p = 0.124 were analyzed statistically between the smoking and non-smoking patients and the two groups were considered to be similar. The average UCLA score for the non-smoking patients (143 was 34 (32 to 35. The average UCLA score for the smoking patients (51 was 33 (29 to 35. There was no statistically significant difference in UCLA score (p = 0.123 between the smoking and non-smoking patients. For the purposes of statistical analysis, we grouped the small and medium tears (107 and compared these with the large and extensive tears (80, between smokers and non-smokers. There was no statistically significant difference using the Mann-Whitney test regarding the small and medium tears (p = 818. There was a statistically significant difference using the Mann-Whitney test regarding the large and extended tears, between the smoking and non-smoking patients, such that the non-smokers showed better UCLA scores (p = 0.038. CONCLUSION: The results from arthroscopic suturing of large and extensive rotator cuff injuries are inferior among smoking patients.

  5. Case Report of Acute Traumatic Rotator Cuff Tear Treatment in Traditional Korean Medicine

    Directory of Open Access Journals (Sweden)

    Jeong-Hwan Lee

    2011-12-01

    Full Text Available Objectives: There is no report on treatment of acute traumatic rotator cuff tear in Traditional Korean Medicine. We reported Traditional Korean Treatment for pain relief and better movement of acute traumatic rotator cuff tear. Methods: Shoulder MRI was used to confirm the diagnosis of tear of rotator cuff. The patient was treated with Traditional Korean Methods (Acupuncture, Herbal medicine, Pharmacopuncture for 6 months. We evaluated the patient through VAS (Visual Analogue Scale, UCLA shoulder scale, ROM (Range of motion and Shoulder MRI. Results: After 6 months of treatment, the patient's VAS was decreased whereas UCLA score and Shoulder ROM were increased. Rotator cuff tear was repaired on Shoulder MRI images. Conclusions: In acute traumatic rotator cuff tear, Korean Traditional Treatment is good method for pain relief and better movement.

  6. Study of fish response using particle image velocimetry and high-speed, high-resolution imaging

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Richmond, M. C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mueller, R. P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gruensch, G. R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2004-10-01

    Fish swimming has fascinated both engineers and fish biologists for decades. Digital particle image velocimetry (DPIV) and high-speed, high-resolution digital imaging are recently developed analysis tools that can help engineers and biologists better understand how fish respond to turbulent environments. This report details studies to evaluate DPIV. The studies included a review of existing literature on DPIV, preliminary studies to test the feasibility of using DPIV conducted at our Flow Biology Laboratory in Richland, Washington September through December 2003, and applications of high-speed, high-resolution digital imaging with advanced motion analysis to investigations of fish injury mechanisms in turbulent shear flows and bead trajectories in laboratory physical models. Several conclusions were drawn based on these studies, which are summarized as recommendations for proposed research at the end of this report.

  7. Study on edge-extraction of remote sensing image

    International Nuclear Information System (INIS)

    Wen Jianguang; Xiao Qing; Xu Huiping

    2005-01-01

    Image edge-extraction is an important step in image processing and recognition, and also a hot spot in science study. In this paper, based on primary methods of the remote sensing image edge-extraction, authors, for the first time, have proposed several elements which should be considered before processing. Then, the qualities of several methods in remote sensing image edge-extraction are systematically summarized. At last, taking Near Nasca area (Peru) as an example the edge-extraction of Magmatic Range is analysed. (authors)

  8. Study about Illness: Through the Narrative of "Illness Image"

    OpenAIRE

    岩城, 晶子

    2013-01-01

    In this research, the meaning of the illness was studied from the perpective of Image. From listening to the narrative about two types of Illness Image, i.e., "my illness" and "A's illness, " we found that there was a characteristic that the Illness Image was similar to the real image. In addition, there were several differences between 2 images, which indicated that distance between the narrator and these images had an influence. From the syudy of two cases, it was indicated that Illness Ima...

  9. UCLA accelerator research and development

    International Nuclear Information System (INIS)

    Cline, D.B.

    1992-01-01

    This progress report covers work supported by the above DOE grant over the period November 1, 1991 to July 31, 1992. The work is a program of experimental and theoretical studies in advanced particle accelerator research and development for high energy physics applications. The program features research at particle beam facilities in the United States and includes research on novel high power sources, novel focussing systems (e.g. plasma lens), beam monitors, novel high brightness, high current gun systems, and novel flavor factories in particular the φ Factory

  10. ARIES tokamak reactor study

    International Nuclear Information System (INIS)

    Steiner, D.; Embrechts, M.

    1990-07-01

    This is a status report on technical progress relative to the tasks identified for the fifth year of Grant No. FG02-85-ER52118. The ARIES tokamak reactor study is a multi-institutional effort to develop several visions of the tokamak as an attractive fusion reactor with enhanced economic, safety, and environmental features. The ARIES study is being coordinated by UCLA and involves a number of institutions, including RPI. The RPI group has been pursuing the following areas of research in the context of the ARIES-I design effort: MHD equilibrium and stability analyses; plasma-edge modeling and blanket materials issues. Progress in these areas is summarized herein

  11. Ucla, escuela elemental

    Directory of Open Access Journals (Sweden)

    Neutra, Richard J.

    1962-03-01

    Full Text Available La Escuela Elemental de Preparación de la Universidad de California, en Los Angeles, está dedicada a la educación e investigación y preparación del profesorado de la infancia. Se ha construido en un paraje maravilloso, de frondosa vegetación, frente a un terreno bastante quebrado, circunstancia que presta mayor encanto al conjunto, construido con gran pericia y adaptación al paisaje a base de una dominante horizontalidad, con materiales sencillos (ladrillos, hierro y madera y gran comunicación con la naturaleza mediante grandes cristaleras correderas que ensanchan las clases y las suplementan hacia el jardín de acuerdo con las nuevas normas y prácticas docentes.

  12. Challenges in clinical studies with multiple imaging probes

    International Nuclear Information System (INIS)

    Krohn, Kenneth A.; O'Sullivan, Finbarr; Crowley, John; Eary, Janet F.; Linden, Hannah M.; Link, Jeanne M.; Mankoff, David A.; Muzi, Mark; Rajendran, Joseph G.; Spence, Alexander M.; Swanson, Kristin R.

    2007-01-01

    This article addresses two related issues: (a) When a new imaging agent is proposed, how does the imager integrate it with other biomarkers, either sampled or imaged? (b) When we have multiple imaging agents, is the information additive or duplicative and how is this objectively determined? Molecular biology is leading to new treatment options with reduced normal tissue toxicity, and imaging should have a role in objectively evaluating new treatments. There are two roles for molecular characterization of disease. Molecular imaging measurements before therapy help predict the aggressiveness of disease and identify therapeutic targets and, therefore, help choose the optimal therapy for an individual. Measurements of specific biochemical processes made during or after therapy should be sensitive measures of tumor response. The rules of evidence are not fully developed for the prognostic role of imaging biomarkers, but the potential of molecular imaging provides compelling motivation to push forward with convincing validation studies. New imaging procedures need to be characterized for their effectiveness under realistic clinical conditions to improve the management of patients and achieve a better outcome. The purpose of this article is to promote a critical discussion within the molecular imaging community because our future value to the overall biomedical community will be in supporting better treatment outcomes rather than in detection

  13. Web-based video monitoring of CT and MRI procedures

    Science.gov (United States)

    Ratib, Osman M.; Dahlbom, Magdalena; Kho, Hwa T.; Valentino, Daniel J.; McCoy, J. Michael

    2000-05-01

    A web-based video transmission of images from CT and MRI consoles was implemented in an Intranet environment for real- time monitoring of ongoing procedures. Images captured from the consoles are compressed to video resolution and broadcasted through a web server. When called upon, the attending radiologists can view these live images on any computer within the secured Intranet network. With adequate compression, these images can be displayed simultaneously in different locations at a rate of 2 to 5 images/sec through standard LAN. The quality of the images being insufficient for diagnostic purposes, our users survey showed that they were suitable for supervising a procedure, positioning the imaging slices and for routine quality checking before completion of a study. The system was implemented at UCLA to monitor 9 CTs and 6 MRIs distributed in 4 buildings. This system significantly improved the radiologists productivity by saving precious time spent in trips between reading rooms and examination rooms. It also improved patient throughput by reducing the waiting time for the radiologists to come to check a study before moving the patient from the scanner.

  14. A Study on the Improvement of Digital Periapical Images using Image Interpolation Methods

    International Nuclear Information System (INIS)

    Song, Nam Kyu; Koh, Kwang Joon

    1998-01-01

    Image resampling is of particular interest in digital radiology. When resampling an image to a new set of coordinate, there appears blocking artifacts and image changes. To enhance image quality, interpolation algorithms have been used. Resampling is used to increase the number of points in an image to improve its appearance for display. The process of interpolation is fitting a continuous function to the discrete points in the digital image. The purpose of this study was to determine the effects of the seven interpolation functions when image resampling in digital periapical images. The images were obtained by Digora, CDR and scanning of Ektaspeed plus periapical radiograms on the dry skull and human subject. The subjects were exposed to intraoral X-ray machine at 60 kVp and 70 kVp with exposure time varying between 0.01 and 0.50 second. To determine which interpolation method would provide the better image, seven functions were compared ; (1) nearest neighbor (2) linear (3) non-linear (4) facet model (5) cubic convolution (6) cubic spline (7) gray segment expansion. And resampled images were compared in terms of SNR (Signal to Noise Ratio) and MTF (Modulation Transfer Function) coefficient value. The obtained results were as follows ; 1. The highest SNR value (75.96 dB) was obtained with cubic convolution method and the lowest SNR value (72.44 dB) was obtained with facet model method among seven interpolation methods. 2. There were significant differences of SNR values among CDR, Digora and film scan (P 0.05). 4. There were significant differences of MTF coefficient values between linear interpolation method and the other six interpolation methods (P<0.05). 5. The speed of computation time was the fastest with nearest neighbor method and the slowest with non-linear method. 6. The better image was obtained with cubic convolution, cubic spline and gray segment method in ROC analysis. 7. The better sharpness of edge was obtained with gray segment expansion method

  15. Image based 3D city modeling : Comparative study

    Directory of Open Access Journals (Sweden)

    S. P. Singh

    2014-06-01

    Full Text Available 3D city model is a digital representation of the Earth’s surface and it’s related objects such as building, tree, vegetation, and some manmade feature belonging to urban area. The demand of 3D city modeling is increasing rapidly for various engineering and non-engineering applications. Generally four main image based approaches were used for virtual 3D city models generation. In first approach, researchers were used Sketch based modeling, second method is Procedural grammar based modeling, third approach is Close range photogrammetry based modeling and fourth approach is mainly based on Computer Vision techniques. SketchUp, CityEngine, Photomodeler and Agisoft Photoscan are the main softwares to represent these approaches respectively. These softwares have different approaches & methods suitable for image based 3D city modeling. Literature study shows that till date, there is no complete such type of comparative study available to create complete 3D city model by using images. This paper gives a comparative assessment of these four image based 3D modeling approaches. This comparative study is mainly based on data acquisition methods, data processing techniques and output 3D model products. For this research work, study area is the campus of civil engineering department, Indian Institute of Technology, Roorkee (India. This 3D campus acts as a prototype for city. This study also explains various governing parameters, factors and work experiences. This research work also gives a brief introduction, strengths and weakness of these four image based techniques. Some personal comment is also given as what can do or what can’t do from these softwares. At the last, this study shows; it concluded that, each and every software has some advantages and limitations. Choice of software depends on user requirements of 3D project. For normal visualization project, SketchUp software is a good option. For 3D documentation record, Photomodeler gives good

  16. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  17. Image quality of conventional images of dual-layer SPECTRAL CT: a phantom study.

    Science.gov (United States)

    van Ommen, F; Bennink, E; Vlassenbroek, A; Dankbaar, J W; Schilham, A M R; Viergever, M A; de Jong, H W A M

    2018-05-10

    Spectral CT using a dual layer detector offers the possibility of retrospectively introducing spectral information to conventional CT images. In theory, the dual-layer technology should not come with a dose or image quality penalty for conventional images. In this study, we evaluate the influence of a dual-layer detector (IQon Spectral CT, Philips) on the image quality of conventional CT images, by comparing these images with those of a conventional but otherwise technically comparable single-layer CT scanner (Brilliance iCT, Philips), by means of phantom experiments. For both CT scanners conventional CT images were acquired using four adult scanning protocols: i) body helical, ii) body axial, iii) head helical and iv) head axial. A CATPHAN 600 phantom was scanned to conduct an assessment of image quality metrics at equivalent (CTDI) dose levels. Noise was characterized by means of noise power spectra (NPS) and standard deviation (SD) of a uniform region, and spatial resolution was evaluated with modulation transfer functions (MTF) of a tungsten wire. In addition, contrast-to-noise ratio (CNR), image uniformity, CT number linearity, slice thickness, slice spacing, and spatial linearity were measured and evaluated. Additional measurements of CNR, resolution and noise were performed in two larger phantoms. The resolution levels at 50%, 10% and 5% MTF of the iCT and IQon showed small but significant differences up to 0.25 lp/cm for body scans, and up to 0.2 lp/cm for head scans in favor of the IQon. The iCT and IQon showed perfect CT linearity for body scans, but for head scans both scanners showed an underestimation of the CT numbers of materials with a high opacity. Slice thickness was slightly overestimated for both scanners. Slice spacing was comparable and reconstructed correctly. In addition, spatial linearity was excellent for both scanners, with a maximum error of 0.11 mm. CNR was higher on the IQon compared to the iCT for both normal and larger phantoms with

  18. Feasibility study on X-ray source with pinhole imaging method

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli

    2007-01-01

    In order to verify the feasibility of study on X-ray source with pinhole imaging method, and optimize the design of X-ray pinhole imaging system, an X-ray pinhole imaging equipment was set up. The change of image due to the change of the position and intensity of X-ray source was estimated with mathematical method and validated with experiment. The results show that the change of the spot position and gray of the spot is linearly related with the change of the position and intensity of X-ray source, so it is feasible to study X-ray source with pinhole imaging method in this application. The results provide some references for the design of X-ray pinhole imaging system. (authors)

  19. A longitudinal study of language learners’ images about Russia

    Directory of Open Access Journals (Sweden)

    Nikitina Larisa

    2016-05-01

    Full Text Available Several studies in the field of applied linguistics have explored images held by language learners about a target language country. However, for the most part, these studies focused on learners of modern European languages, such as German, Spanish and French and they were conducted in Western educational contexts. Besides, none of the previous investigations attempted to conduct a systematic classification of the language learners’ images. The present longitudinal study addressed these gaps in the research literature. It explored images about Russia held by Malaysian learners of the Russian language in a large university in East Malaysia. This article reports the findings of three questionnaire surveys conducted in 2004, 2007 and 2010. It was found that the images about Russia held by the participants were diverse and clustered around eight countryrelated aspects. Content of some categories of images was stable and changed little over time. Other categories were more fluid and more prone to change. The paper concludes with a discussion of pedagogical implications that can be derived from the findings.

  20. Regulation of the Prostate Cancer Tumor Microenvironment

    Science.gov (United States)

    2017-06-01

    lipopolysaccharide   (LPS)   found   in   gram-­negative   bacterial  walls   recognized   by   TLR4,   double   stranded  RNA  produced  by  many  viruses  for...UCLA, Los Angeles, California 4Department of Pathology, UCLA, Los Angeles, California 5Eli & Edythe Broad Stem Cell Research Center, UCLA, Los Angeles...Broad Stem Cell Research Center Scholars in Translational Medicine; Grant sponsor: UCLA Broad Stem Cell Research Center Flow Cytometry Core; Grant

  1. [A computer-aided image diagnosis and study system].

    Science.gov (United States)

    Li, Zhangyong; Xie, Zhengxiang

    2004-08-01

    The revolution in information processing, particularly the digitizing of medicine, has changed the medical study, work and management. This paper reports a method to design a system for computer-aided image diagnosis and study. Combined with some good idea of graph-text system and picture archives communicate system (PACS), the system was realized and used for "prescription through computer", "managing images" and "reading images under computer and helping the diagnosis". Also typical examples were constructed in a database and used to teach the beginners. The system was developed by the visual developing tools based on object oriented programming (OOP) and was carried into operation on the Windows 9X platform. The system possesses friendly man-machine interface.

  2. Image Transmission Studies

    Science.gov (United States)

    Blaine, G. James; Hill, Rexford L.; Rueter, Allen P.; Senol, Evren; Studt, James W.

    1988-06-01

    Radiological PACS image sizes and desired retrieval response times demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. Our current PACS experiments are based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel.

  3. Comparative imaging study on monkeys with hemi-parkinsonism

    International Nuclear Information System (INIS)

    Wang Wei; Yu Xiaoping; Mao Jun; Liu Sheng; Wang Xiaoyi; Peng Guangchun; Wang Ruiwen

    2003-01-01

    Objective: To study the imaging appearance of experimental Parkinson's disease (PD) and to evaluate the different medical imaging exams on PD. Methods: CT, MRI, SPECT (dopamine transporter imaging and regional cerebral blood flow imaging, DAT imaging and rCBF imaging), and PET (glucose metabolism imaging) were performed on 8 monkeys before and after the infusion of MPTP into unilateral internal carotid artery to develop hemi-Parkinsonism models. Results: Hemi-Parkinsonism models were successfully induced on all 8 monkeys. On DAT imaging, the uptake values of the lesioned striatums decreased obviously after the MPTP treatment and were lower than that of the contralateral ones. The glucose metabolic rates of the lesioned striatums and thalamus in PD models were lower, compared to that of the healthy monkeys and that of the contralateral sides of themselves. Neither DAT nor glucose metabolism abnormalities was found on both the contralateral sides of the healthy and PD monkeys. On MRI images before MPTP treatment, only 4 of 8 PD models showed hypointense in bilateral globus pallidus. No abnormal MRI findings occurred in the first 2 months after injection of MPTP. At tile third month, hypointense appeared in globus pallidus of three monkeys. Enlarged hyposignal region in globus pallidus were found in three models. Of the above 6 monkeys, two appeared hypointense in putamina. Substantia nigra demonstrated no abnormalities before and after MPTP treatment. All rCBF and CT images were normal. Conclusion: The decreased density of DAT and decreased glucose metabolism on experimental PD can be showed early by DAT imaging and glucose metabolism imaging, MRI can show abnormal signal in the basal ganglia of PD but it is later than DAT and glucose metabolism imaging. CT and rCBF find no abnormality on PD

  4. ATS-6 - UCLA fluxgate magnetometer

    Science.gov (United States)

    Mcpherron, R. L.; Coleman, P. J., Jr.; Snare, R. C.

    1975-01-01

    A summary of the design of the University of California at Los Angeles' fluxgate magnetometer is presented. Instrument noise in the bandwidth 0.001 to 1.0 Hz is of order 85 m gamma. The DC field of the spacecraft transverse to the earth-pointing axis is 1.0 + or - 21 gamma in the X direction and -2.4 + or - 1.3 gamma in the Y direction. The spacecraft field parallel to this axis is less than 5 gamma. The small spacecraft field has made possible studies of the macroscopic field not previously possible at synchronous orbit. At the 96 W longitude of Applications Technology Satellite-6 (ATS-6), the earth's field is typically inclined 30 deg to the dipole axis at local noon. Most perturbations of the field are due to substorms. These consist of a rotation in the meridian to a more radial field followed by a subsequent rotation back. The rotation back is normally accompanied by transient variations in the azimuthal field. The exact timing of these perturbations is a function of satellite location and the details of substorm development.

  5. Feasibility study of CT perfusion imaging for prostate carcinoma

    International Nuclear Information System (INIS)

    Cullu, Nesat; Kantarci, Mecit; Ogul, Hayri; Pirimoglu, Berhan; Karaca, Leyla; Kizrak, Yesim; Adanur, Senol; Koc, Erdem; Polat, Ozkan; Okur, Aylin

    2014-01-01

    The aim of this feasibility study was to obtain initial data with which to assess the efficiency of perfusion CT imaging (CTpI) and to compare this with magnetic resonance imaging (MRI) in the diagnosis of prostate carcinoma. This prospective study involved 25 patients with prostate carcinoma undergoing MRI and CTpI. All analyses were performed on T2-weighted images (T2WI), apparent diffusion coefficient (ADC) maps, diffusion-weighted images (DWI) and CTp images. We compared the performance of T2WI combined with DWI and CTp alone. The study was approved by the local ethics committee, and written informed consent was obtained from all patients. Tumours were present in 87 areas according to the histopathological results. The diagnostic performance of the T2WI+DWI+CTpI combination was significantly better than that of T2WI alone for prostate carcinoma (P < 0.001). The diagnostic value of CTpI was similar to that of T2WI+DWI in combination. There were statistically significant differences in the blood flow and permeability surface values between prostate carcinoma and background prostate on CTp images. CTp may be a valuable tool for detecting prostate carcinoma and may be preferred in cases where MRI is contraindicated. If this technique is combined with T2WI and DWI, its diagnostic value is enhanced. (orig.)

  6. Image transmission studies

    International Nuclear Information System (INIS)

    Blaine, G.J.; Hill, R.L.; Rueter, A.P.; Senol, E.; Studt, J.W.

    1988-01-01

    This paper discusses radiological PACS image sizes and desired retrieval response time that demand high-bandwidth communication networks. Local area network technology at speeds higher that 10 Megabits/second (IEEE 802.3) have not achieved standardization nor production volume. The authors describe current PACS experiments based on a three-level subnet approach using 10 Mb/s Ethernet channels. An Ethernet channel is shown to support image transfers at an average throughput of 3 Mb/s. Preliminary measurements and simulation results suggest that traffic from as many as two-to-three archives can be supported on the same channel

  7. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  8. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-15

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with {sup 99m}Tc-MDP, DMSA, and {sup 18}F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, {sup 99m}Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined {sup 99}mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and {sup 18}F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug.

  9. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-01

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc-MDP, DMSA, and 18 F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, 99m Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined 99 mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and 18 F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  10. Fluorescence Imaging Study of Transition in Underexpanded Free Jets

    Science.gov (United States)

    Wilkes, Jennifer A.; Danehy, Paul M.; Nowak, Robert J.

    2005-01-01

    Planar laser-induced fluorescence (PLIF) is demonstrated to be a valuable tool for studying the onset of transition to turbulence. For this study, we have used PLIF of nitric oxide (NO) to image underexpanded axisymmetric free jets issuing into a low-pressure chamber through a smooth converging nozzle with a sonic orifice. Flows were studied over a range of Reynolds numbers and nozzle-exit-to-ambient pressure ratios with the aim of empirically determining criteria governing the onset of turbulence. We have developed an image processing technique, involving calculation of the standard deviation of the intensity in PLIF images, in order to aid in the identification of turbulence. We have used the resulting images to identify laminar, transitional and turbulent flow regimes. Jet scaling parameters were used to define a rescaled Reynolds number that incorporates the influence of a varying pressure ratio. An empirical correlation was found between transition length and this rescaled Reynolds number for highly underexpanded jets.

  11. What Images Reveal: a Comparative Study of Science Images between Australian and Taiwanese Junior High School Textbooks

    Science.gov (United States)

    Ge, Yun-Ping; Unsworth, Len; Wang, Kuo-Hua; Chang, Huey-Por

    2017-07-01

    From a social semiotic perspective, image designs in science textbooks are inevitably influenced by the sociocultural context in which the books are produced. The learning environments of Australia and Taiwan vary greatly. Drawing on social semiotics and cognitive science, this study compares classificational images in Australian and Taiwanese junior high school science textbooks. Classificational images are important kinds of images, which can represent taxonomic relations among objects as reported by Kress and van Leeuwen (Reading images: the grammar of visual design, 2006). An analysis of the images from sample chapters in Australian and Taiwanese high school science textbooks showed that the majority of the Taiwanese images are covert taxonomies, which represent hierarchical relations implicitly. In contrast, Australian classificational images included diversified designs, but particularly types with a tree structure which depicted overt taxonomies, explicitly representing hierarchical super-ordinate and subordinate relations. Many of the Taiwanese images are reminiscent of the specimen images in eighteenth century science texts representing "what truly is", while more Australian images emphasize structural objectivity. Moreover, Australian images support cognitive functions which facilitate reading comprehension. The relationships between image designs and learning environments are discussed and implications for textbook research and design are addressed.

  12. Study of scattering in bi-dimensional neutron radiographic images

    International Nuclear Information System (INIS)

    Oliveira, K.A.M. de; Crispim, V.R.; Silva, F.C.

    2009-01-01

    The effect of neutron scattering frequently causes distortions in neutron radiographic images and, thus, reduces the quality. In this project, a type of filter, comprised of cadmium (a neutron absorber), was used in the form of a grid to correct this effect. This device generated image data in the discrete shadow bands of the absorber, components relative to neutron scattering on the test object and surroundings. Scattering image data processing, together with the original neutron radiographic image, resulted in a corrected image with improved edge delineation and, thus, greater definition in the neutron radiographic image of the test object. The objective of this study is to propose a theoretical/experimental methodology that is capable of eliminating the components relative to neutron scattering in neutron radiographic images, coming from the material that composes the test object and the materials that compose the surrounding area. (author)

  13. Cloud feedback studies with a physics grid

    Energy Technology Data Exchange (ETDEWEB)

    Dipankar, Anurag [Max Planck Institute for Meteorology Hamburg; Stevens, Bjorn [Max Planck Institute for Meteorology Hamburg

    2013-02-07

    During this project the investigators implemented a fully parallel version of dual-grid approach in main frame code ICON, implemented a fully conservative first-order interpolation scheme for horizontal remapping, integrated UCLA-LES micro-scale model into ICON to run parallely in selected columns, and did cloud feedback studies on aqua-planet setup to evaluate the classical parameterization on a small domain. The micro-scale model may be run in parallel with the classical parameterization, or it may be run on a "physics grid" independent of the dynamics grid.

  14. A study on secondary images in panoramic radiograph

    International Nuclear Information System (INIS)

    Cho, Dai Hee; Kim, Han Pyong

    1984-01-01

    This study was performed to observe the secondary images and to analyse the relationships between the primary and secondary images in panoramic radiograph. Using the Morita's Panex-EC panoramic x-ray machine and the human dry skull, the author analysed 17 radiographs which were selected from 65 radiographs of the dry skull that attached the radiopaque materials, and the attached regions of the radiopaque materials were the normal anatomical structures which were important and selected as a region for the evaluation of the secondary images effectively. The results were as follows; 1. The cervical vertebrae showed three images. The midline image was the most distorted and less clear, and bilateral images were slightly superimposed over the posterior border of the mandibular ramus. 2. In mandible, the secondary image of the posterior border of the ramus was superimposed on the opposite ramus region, and this image was elongated from the anterior border of the ramus to the lateral side of the posterior border of the ramus. The secondary image of the condyle was observed on the upper area of the coronoid process, the sigmoid notch and the condyle in opposite side. 3. In maxilla, the posterior region of the hard palate showed the secondary image on the lower part of the nasal cavity and the medial wall of the maxillary sinus. 4. The primary images of the occipital condyle and the mastoid process appeared on the same region, and only the secondary image of the occipital condyle was observed symmetrically on the opposite side with similar shape to the primary one. 5. In the cranial base, the anatomical structures of the midsagittal portions like a inferior border of the frontal sinus, sella turcica, inferior border of the sphenoid sinus and inferior border of the posterior part of the occipital bone showed the similar shape between the primary and secondary images symmetrically. 6. The petrous portion of the temporal bone showed the secondary image of the lateral side of

  15. Studying depression using imaging and machine learning methods.

    Science.gov (United States)

    Patel, Meenal J; Khalaf, Alexander; Aizenstein, Howard J

    2016-01-01

    Depression is a complex clinical entity that can pose challenges for clinicians regarding both accurate diagnosis and effective timely treatment. These challenges have prompted the development of multiple machine learning methods to help improve the management of this disease. These methods utilize anatomical and physiological data acquired from neuroimaging to create models that can identify depressed patients vs. non-depressed patients and predict treatment outcomes. This article (1) presents a background on depression, imaging, and machine learning methodologies; (2) reviews methodologies of past studies that have used imaging and machine learning to study depression; and (3) suggests directions for future depression-related studies.

  16. NMR imaging studies of coal

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Z.R.; Zhang, P.Z.; Ding, G.L.; Li, L.Y.; Ye, C.H. [University of Science and Technology, Beijing (China). Dept. of Chemistry

    1996-06-01

    The permeation transportation and swelling behavior of solvents into coal are investigated by NMR imaging using pyridine-d{sub 5} and acetone-d{sub 6}. Images of coal swollen with deuterated solvents illuminate proton distributions of mobile phases within the coal macromolecular networks. More information about the chemical and physical structure of coal can be obtained using NMR imaging techniques.

  17. Physical acoustics at UCLA in the study of superfluid helium

    International Nuclear Information System (INIS)

    Rudnick, I.

    1976-01-01

    The theory of sound propagation in superfluid helium is reviewed. The theory of first, second, fourth and third sound is considered. A simple approximate derivation of the velocity of third sound is given and the Doppler shift of first, second, third and fourth sound is discussed. Experimental aspects of first, second, third and fourth sound are considered in turn. For first sound consideration is given to first-sound transducers, cavitation in liquid helium and velocity at the lambda transition. Second-sound transducers and the velocity of second sound at the lambda transition are discussed. Experimental aspects of third-sound transducers, the velocity and attenuation of third sound, the critical velocity of superfluid films and the thickness of a moving film are then discussed. Various aspects of fourth sound are considered. (B.R.H.)

  18. COMPARATIVE STUDY OF EDGE BASED LSB MATCHING STEGANOGRAPHY FOR COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    A.J. Umbarkar

    2016-02-01

    Full Text Available Steganography is a very pivotal technique mainly used for covert transfer of information over a covert communication channel. This paper proposes a significant comparative study of the spatial LSB domain technique that focuses on sharper edges of the color as well as gray scale images for the purpose of data hiding and hides secret message first in sharper edge regions and then in smooth regions of the image. Message embedding depends on content of the image and message size. The experimental results illustrate that, for low embedding rate the method hides the message in sharp edges of cover image to get better stego image visualization quality. For high embedding rate, smooth regions and edges of the cover image are used for the purpose of data hiding. In this steganography method, color image and textured kind of image preserves better visual quality of stego image. The novelty of the comparative study is that, it helps to analyze the efficiency and performance of the method as it gives better results because it directly works on color images instead of converting to gray scale image.

  19. Comparative study of image restoration techniques in forensic image processing

    Science.gov (United States)

    Bijhold, Jurrien; Kuijper, Arjan; Westhuis, Jaap-Harm

    1997-02-01

    In this work we investigated the forensic applicability of some state-of-the-art image restoration techniques for digitized video-images and photographs: classical Wiener filtering, constrained maximum entropy, and some variants of constrained minimum total variation. Basic concepts and experimental results are discussed. Because all methods appeared to produce different results, a discussion is given of which method is the most suitable, depending on the image objects that are questioned, prior knowledge and type of blur and noise. Constrained minimum total variation methods produced the best results for test images with simulated noise and blur. In cases where images are the most substantial part of the evidence, constrained maximum entropy might be more suitable, because its theoretical basis predicts a restoration result that shows the most likely pixel values, given all the prior knowledge used during restoration.

  20. Software Engineering Support of the Third Round of Scientific Grand Challenge Investigations: An Earth Modeling System Software Framework Strawman Design that Integrates Cactus and UCLA/UCB Distributed Data Broker

    Science.gov (United States)

    Talbot, Bryan; Zhou, Shu-Jia; Higgins, Glenn

    2002-01-01

    One of the most significant challenges in large-scale climate modeling, as well as in high-performance computing in other scientific fields, is that of effectively integrating many software models from multiple contributors. A software framework facilitates the integration task. both in the development and runtime stages of the simulation. Effective software frameworks reduce the programming burden for the investigators, freeing them to focus more on the science and less on the parallel communication implementation, while maintaining high performance across numerous supercomputer and workstation architectures. This document proposes a strawman framework design for the climate community based on the integration of Cactus, from the relativistic physics community, and UCLA/UCB Distributed Data Broker (DDB) from the climate community. This design is the result of an extensive survey of climate models and frameworks in the climate community as well as frameworks from many other scientific communities. The design addresses fundamental development and runtime needs using Cactus, a framework with interfaces for FORTRAN and C-based languages, and high-performance model communication needs using DDB. This document also specifically explores object-oriented design issues in the context of climate modeling as well as climate modeling issues in terms of object-oriented design.

  1. Software Image J to study soil pore distribution

    Directory of Open Access Journals (Sweden)

    Sabrina Passoni

    2014-04-01

    Full Text Available In the soil science, a direct method that allows the study of soil pore distribution is the bi-dimensional (2D digital image analysis. Such technique provides quantitative results of soil pore shape, number and size. The use of specific softwares for the treatment and processing of images allows a fast and efficient method to quantify the soil porous system. However, due to the high cost of commercial softwares, public ones can be an interesting alternative for soil structure analysis. The objective of this work was to evaluate the quality of data provided by the Image J software (public domain used to characterize the voids of two soils, characterized as Geric Ferralsol and Rhodic Ferralsol, from the southeast region of Brazil. The pore distribution analysis technique from impregnated soil blocks was utilized for this purpose. The 2D image acquisition was carried out by using a CCD camera coupled to a conventional optical microscope. After acquisition and treatment of images, they were processed and analyzed by the software Noesis Visilog 5.4® (chosen as the reference program and ImageJ. The parameters chosen to characterize the soil voids were: shape, number and pore size distribution. For both soils, the results obtained for the image total porosity (%, the total number of pores and the pore size distribution showed that the Image J is a suitable software to be applied in the characterization of the soil sample voids impregnated with resin.

  2. A study of metal artifacts on MR imaging. Evaluation of scanning parameters

    International Nuclear Information System (INIS)

    Yamashiro, Mitsuaki

    1999-01-01

    The purpose of this study was to evaluate scanning parameters on MR imaging for reducing metal artifacts using phantom study. Metal artifacts on sagittal images, perpendicular to static magnetic direction showed round shape in the relationship between shape of metal artifacts on MR images and scanning direction. Metal artifacts on both axial and coronal images, parallel to static magnetic direction showed oval shape in the direction of X-axis. In spin echo sequences, the largest dimension of metal artifacts was coronal image, followed by axial image and then sagittal image. In gradient echo sequences, the largest dimension of metal artifacts was axial image, followed by coronal image and then sagittal image. The best scanning plane for reducing metal artifacts was perpendicular to static magnetic direction. In scanning sequences, the largest dimensions of metal artifacts were gradient echo sequences, followed by T2-weighted spin echo sequence and then proton density-weighted and T1-weighted spin echo sequences. Large flip angle increased much metal artifacts on both axial and coronal images in gradient echo sequences. Small flip angle was useful for reducing metal artifacts on both axial and coronal images. The influence of flip angle on metal artifacts in sagittal images perpendicular static magnetic direction was less than for images in coronal and axial planes on gradient echo sequences. These results suggested that a study of metal artifacts on MR imaging about evaluation of scanning parameters was useful to reduce metal artifacts on MR images. (K.H.)

  3. Phantom and animal imaging studies using PLS synchrotron X-rays

    CERN Document Server

    Hee Joung Kim; Kyu Ho Lee; Hai Jo Jung; Eun Kyung Kim; Jung Ho Je; In Woo Kim; Yeukuang, Hwu; Wen Li Tsai; Je Kyung Seong; Seung Won Lee; Hyung Sik Yoo

    2001-01-01

    Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ultra-high resolution images for, resolution test patterns, mammograph...

  4. Arthroscopic Rotator Cuff Repair With Graft Augmentation of 3-Dimensional Biological Collagen for Moderate to Large Tears: A Randomized Controlled Study.

    Science.gov (United States)

    Cai, You-Zhi; Zhang, Chi; Jin, Ri-Long; Shen, Tong; Gu, Peng-Cheng; Lin, Xiang-Jin; Chen, Jian-De

    2018-05-01

    Due to the highly organized tissue and avascular nature of the rotator cuff, rotator cuff tears have limited ability to heal after the tendon is reinserted directly on the greater tubercle of the humerus. Consequently, retears are among the most common complications after rotator cuff repair. Augmentation of rotator cuff repairs with patches has been an active area of research in recent years to reduce retear rate. Graft augmentation with 3D collagen could prevent retears of the repaired tendon and improve tendon-bone healing in moderate to large rotator cuff tears. Randomized controlled study; Level of evidence, 2. A prospective, randomized controlled study was performed in a consecutive series of 112 patients age 50 to 85 years who underwent rotator cuff repair with the suture-bridge technique (58 patients, control group) or the suture-bridge technique augmented with 3-dimensional (3D) collagen (54 patients, study group). All patients were followed for 28.2 months (range, 24-36 months). Visual analog scale score for pain, University of California Los Angeles (UCLA) shoulder score, and Constant score were determined. Magnetic resonance imaging was performed pre- and postoperatively (at a minimum of 24 months) to evaluate the integrity of the rotator cuff and the retear rate of the repaired tendon. Three patients in each group had biopsies at nearly 24 months after surgery with histological assessment and transmission electron microscopy. A total of 104 patients completed the final follow-up. At the 12-month follow-up, the UCLA shoulder score was 28.1 ± 1.9 in the study group, which was significantly better than that in the control group (26.9 ± 2.1, P = .002). The Constant score was also significantly better in the study group (87.1 ± 3.2) than in the control group (84.9 ± 4.2, P = .003). However, at the final follow-up, no significant differences were found in the UCLA shoulder scores (29.4 ± 1.9 in the control group and 30.0 ± 1.6 in the study group, P

  5. A Study of Identification Performance of Facial Regions from CCTV Images

    NARCIS (Netherlands)

    Ali, Tauseef; Tome, Pedro; Fierrez, Julian; Vera-Rodriguez, Ruben; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.; Garain, Utpal; Shafait, Faisal

    This paper focuses on automatic face identification for forensic applications. Forensic examiners compare different parts of the face image obtained from a closed-circuit television (CCTV) image with a database of mug shots or good quality image(s) taken from the suspect. In this work we study and

  6. A study of identification performance of facial regions from CCTV images

    NARCIS (Netherlands)

    Ali, Tauseef; Tom, P.; Fierrez, J.; Vera-Rodriguez, R.; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.

    2012-01-01

    This paper focuses on automatic face identification for forensic applications. Forensic examiners compare different parts of the face image obtained from a closed-circuit television (CCTV) image with a database of mug shots or good quality image(s) taken from the suspect. In this work we study and

  7. Studying depression using imaging and machine learning methods

    Directory of Open Access Journals (Sweden)

    Meenal J. Patel

    2016-01-01

    Full Text Available Depression is a complex clinical entity that can pose challenges for clinicians regarding both accurate diagnosis and effective timely treatment. These challenges have prompted the development of multiple machine learning methods to help improve the management of this disease. These methods utilize anatomical and physiological data acquired from neuroimaging to create models that can identify depressed patients vs. non-depressed patients and predict treatment outcomes. This article (1 presents a background on depression, imaging, and machine learning methodologies; (2 reviews methodologies of past studies that have used imaging and machine learning to study depression; and (3 suggests directions for future depression-related studies.

  8. Study of check image using computed radiography

    International Nuclear Information System (INIS)

    Sato, Hiroshi

    2002-01-01

    There are two image forming methods both a check image and a portal image in the linacogram. It has been established the image forming method in the check image using computed radiography (CR). On the other hand, it is not established the image forming method in the portal image using CR yet. Usually, in the electric portal imaging device (EPID) is mainly used just before radiotherapy start. The usefulness of the portal image forming method by CR using in place of EPID is possible to confirm the precision for determining to specific position at the irradiate part and to the irradiate method for the human organs. There are some technical problems that, since in the early time, the linac graphy (LG) image have low resolution power. In order to improve to the resolution power in LG image, CR image technologies have been introduced to the check image forming method. Heavy metallic sheet (HMS) is used to the front side of CR-IP cassette, and high contactness sponge is used to the back side of the cassette. Improved contactness between HMS and imaging plate (IP) by means of the high contactness sponge contributed to improve the resolution power in the check images. A lot of paper which is connected with these information have been reported. Imaging plate ST-III should be used to maintain high sensitivity in the check film image forming method. The same image forming method in the check image established by CR has been introduced into the portal image forming method in order to improve the resolution power. However, as a result, it couldn't acquired high resolution image forming in the portal images because of the combination of ST-III and radiotherapy dose. After several trials, it has been recognized that HR-V imaging plate for mammography is the most useful application to maintain high resolution power in the portal images. Also, it is possible to modify the image quality by changing GS parameter which is one of image processing parameters in CR. Furthermore, in case

  9. Unique roles of SPET brain imaging in clinical and research studies

    International Nuclear Information System (INIS)

    Seibyl, J.; Jennings, D.; Tabamo, R.; Marek, K.

    2005-01-01

    The increasing availability of PET imaging in Nuclear medicine expands the armamentarium of clinical and research tools for improving diagnosis and treatment of neuropsychiatric disorders. Nonetheless, the role of SPEC imaging remains critical to both research and clinical practice. The development of rational strategies for guiding the selection of imaging modalities flows from primarily the nature of the clinical or research question and the availability of appropriate radiopharmaceuticals. There has been extensive SPECT and PET work in Parkinson's disease (PD) which highlights the value of both these scintigraphic modalities. Three main areas of interest in PD include imaging for improving diagnostic accuracy, for monitoring the progression of disease, and for assessing the therapeutic efficacy of drugs with neoroprotective potential. The demands of the clinical or research question posed to imaging dictates the selection of radiotracer and imaging modality. Diagnosis of PD represents the easiest challenge with many imaging bio markers showing high sensitivity for detecting abnormal reduction of dopaminergic function based on qualitative review of images. On the other hand, using imaging to evaluate treatments which purportedly slow the rate of disease progression, indicated by the reduction of the rate of loss in a quantitative imaging signal in patients studied over time, represents the most rigorous requirement of the imaging measure. In each of these applications presynaptic markers of dopaminergic function using SPECT and PET have been extremely valuable. Review of neuroimaging studies of PD provides a useful example of optimized approaches to clinical and research studies in neuropsychiatric disorders

  10. Fuel assembly assessment from CVD image analysis: A feasibility study

    International Nuclear Information System (INIS)

    Lindsay, C.S.; Lindblad, T.

    1997-05-01

    The Swedish Nuclear Inspectorate commissioned a feasibility study of automatic assessment of fuel assemblies from images obtained with the digital Cerenkov viewing device currently in development. The goal is to assist the IAEA inspectors in evaluating the fuel since they typically have only a few seconds to inspect an assembly. We report results here in two main areas: Investigation of basic image processing and recognition techniques needed to enhance the images and find the assembly in the image; Study of the properties of the distributions of light from the assemblies to determine whether they provide unique signatures for different burn-up and cooling times for real fuel or indicate presence of non-fuel. 8 refs, 27 figs

  11. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  12. Scatterometry or imaging overlay: a comparative study

    Science.gov (United States)

    Hsu, Simon C. C.; Pai, Yuan Chi; Chen, Charlie; Yu, Chun Chi; Hsing, Henry; Wu, Hsing-Chien; Kuo, Kelly T. L.; Amir, Nuriel

    2015-03-01

    Most fabrication facilities today use imaging overlay measurement methods, as it has been the industry's reliable workhorse for decades. In the last few years, third-generation Scatterometry Overlay (SCOL™) or Diffraction Based Overlay (DBO-1) technology was developed, along another DBO technology (DBO-2). This development led to the question of where the DBO technology should be implemented for overlay measurements. Scatterometry has been adopted for high volume production in only few cases, always with imaging as a backup, but scatterometry overlay is considered by many as the technology of the future. In this paper we compare imaging overlay and DBO technologies by means of measurements and simulations. We outline issues and sensitivities for both technologies, providing guidelines for the best implementation of each. For several of the presented cases, data from two different DBO technologies are compared as well, the first with Pupil data access (DBO-1) and the other without pupil data access (DBO-2). Key indicators of overlay measurement quality include: layer coverage, accuracy, TMU, process robustness and robustness to process changes. Measurement data from real cases across the industry are compared and the conclusions are also backed by simulations. Accuracy is benchmarked with reference OVL, and self-consistency, showing good results for Imaging and DBO-1 technology. Process sensitivity and metrology robustness are mostly simulated with MTD (Metrology Target Designer) comparing the same process variations for both technologies. The experimental data presented in this study was done on ten advanced node layers and three production node layers, for all phases of the IC fabrication process (FEOL, MEOL and BEOL). The metrology tool used for most of the study is KLA-Tencor's Archer 500LCM system (scatterometry-based and imaging-based measurement technologies on the same tool) another type of tool is used for DBO-2 measurements. Finally, we conclude that

  13. Clinical findings versus imaging studies in the diagnosis of infantile ...

    African Journals Online (AJOL)

    Background: Infantile hypertrophic pyloric stenosis is the most common surgical cause of vomiting in early infancy and can be diagnosed clinically or by imaging studies. Objectives: The aim of this study was to assess the accuracy of clinical examination compared with ultrasound and upper gastrointestinal contrast imaging ...

  14. Changes of radio-technological studies in the field of medical imaging. From analogous studies to digital ones

    International Nuclear Information System (INIS)

    Shiraishi, Junji; Uchiyama, Yoshikazu; Honda, Michitaka; Ogura, Toshihiro; Kunitomo, Hiroshi; Kishimoto, Kenji; Ishii, Rie; Hara, Takeshi; Tanaka, Rie

    2014-01-01

    Eight authors briefly describe practical reviews of domestic changes in the title of their expertized field for the purpose of enlightenment. Reviews concern following studies: on the construction of medical images, on characteristics of input/output, of resolution, of noise, on whole assessment of images with noise-equivalent number of quanta/detective quantum efficiency (NEQ/DQE), with subjectivity, on computer-aided diagnosis (CAD), and on image displaying system assessment. X-ray image subtraction along with the development of CT is the origin of real-time digitalized image construction. Studies on the input/output affects the quality of images and exposure dose to patients, which have contributed to works of investigators at manufacturing and technologists on site. Then described are changes in the assessment of image by digital radiography (DR), of which basis was originally established at analogous sensitizer/film (S/F) era, of image resolution and of noise characteristic assessment, during the period from S/F to DR systems. Assessment of images with NEQ/DQE has been essentially based on the description in the 'Image Science' published in 1974 and its derived domestic educational researches; and the assessment with subjectivity involves the receiver operating characteristic (ROC), which leads to computer-aided diagnosis (CAD). Studies on image display are now changing responding to clinical and social needs. (T.T.)

  15. Feasibility study and quality assessment of unmanned aircraft system-derived multispectral images

    Science.gov (United States)

    Chang, Kuo-Jen

    2017-04-01

    The purpose of study is to explore the precision and the applicability of UAS-derived multispectral images. In this study, the Micro-MCA6 multispectral camera was mounted on quadcopter. The Micro-MCA6 shoot images synchronized of each single band. By means of geotagged images and control points, the orthomosaic images of each single band generated firstly by 14cm resolution. The multispectral image was merged complete with 6 bands. In order to improve the spatial resolution, the 6 band image fused with 9cm resolution image taken from RGB camera. Quality evaluation of the image is verified of the each single band by using control points and check points. The standard deviations of errors are within 1 to 2 pixel resolution of each band. The quality of the multispectral image is compared with 3 cm resolution orthomosaic RGB image gathered from UAV in the same mission, as well. The standard deviations of errors are within 2 to 3 pixel resolution. The result shows that the errors resulting from the blurry and the band dislocation of the objects edge identification. To the end, the normalized difference vegetation index (NDVI) extracted from the image to explore the condition of vegetation and the nature of the environment. This study demonstrates the feasibility and the capability of the high resolution multispectral images.

  16. Processed images in human perception: A case study in ultrasound breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yap, Moi Hoon [Department of Computer Science, Loughborough University, FH09, Ergonomics and Safety Research Institute, Holywell Park (United Kingdom)], E-mail: M.H.Yap@lboro.ac.uk; Edirisinghe, Eran [Department of Computer Science, Loughborough University, FJ.05, Garendon Wing, Holywell Park, Loughborough LE11 3TU (United Kingdom); Bez, Helmut [Department of Computer Science, Loughborough University, Room N.2.26, Haslegrave Building, Loughborough University, Loughborough LE11 3TU (United Kingdom)

    2010-03-15

    Two main research efforts in early detection of breast cancer include the development of software tools to assist radiologists in identifying abnormalities and the development of training tools to enhance their skills. Medical image analysis systems, widely known as Computer-Aided Diagnosis (CADx) systems, play an important role in this respect. Often it is important to determine whether there is a benefit in including computer-processed images in the development of such software tools. In this paper, we investigate the effects of computer-processed images in improving human performance in ultrasound breast cancer detection (a perceptual task) and classification (a cognitive task). A survey was conducted on a group of expert radiologists and a group of non-radiologists. In our experiments, random test images from a large database of ultrasound images were presented to subjects. In order to gather appropriate formal feedback, questionnaires were prepared to comment on random selections of original images only, and on image pairs consisting of original images displayed alongside computer-processed images. We critically compare and contrast the performance of the two groups according to perceptual and cognitive tasks. From a Receiver Operating Curve (ROC) analysis, we conclude that the provision of computer-processed images alongside the original ultrasound images, significantly improve the perceptual tasks of non-radiologists but only marginal improvements are shown in the perceptual and cognitive tasks of the group of expert radiologists.

  17. Processed images in human perception: A case study in ultrasound breast imaging

    International Nuclear Information System (INIS)

    Yap, Moi Hoon; Edirisinghe, Eran; Bez, Helmut

    2010-01-01

    Two main research efforts in early detection of breast cancer include the development of software tools to assist radiologists in identifying abnormalities and the development of training tools to enhance their skills. Medical image analysis systems, widely known as Computer-Aided Diagnosis (CADx) systems, play an important role in this respect. Often it is important to determine whether there is a benefit in including computer-processed images in the development of such software tools. In this paper, we investigate the effects of computer-processed images in improving human performance in ultrasound breast cancer detection (a perceptual task) and classification (a cognitive task). A survey was conducted on a group of expert radiologists and a group of non-radiologists. In our experiments, random test images from a large database of ultrasound images were presented to subjects. In order to gather appropriate formal feedback, questionnaires were prepared to comment on random selections of original images only, and on image pairs consisting of original images displayed alongside computer-processed images. We critically compare and contrast the performance of the two groups according to perceptual and cognitive tasks. From a Receiver Operating Curve (ROC) analysis, we conclude that the provision of computer-processed images alongside the original ultrasound images, significantly improve the perceptual tasks of non-radiologists but only marginal improvements are shown in the perceptual and cognitive tasks of the group of expert radiologists.

  18. Adapting Parcellation Schemes to Study Fetal Brain Connectivity in Serial Imaging Studies

    DEFF Research Database (Denmark)

    Cheng, Xi; Wilm, Jakob; Seshamani, Sharmishtaa

    2013-01-01

    A crucial step in studying brain connectivity is the definition of the Regions Of Interest (ROI's) which are considered as nodes of a network graph. These ROI's identified in structural imaging reflect consistent functional regions in the anatomies being compared. However in serial studies...... of the developing fetal brain such functional and associated structural markers are not consistently present over time. In this study we adapt two non-atlas based parcellation schemes to study the development of connectivity networks of a fetal monkey brain using Diffusion Weighted Imaging techniques. Results...... demonstrate that the fetal brain network exhibits small-world characteristics and a pattern of increased cluster coefficients and decreased global efficiency. These findings may provide a route to creating a new biomarker for healthy fetal brain development....

  19. TREE STEM RECONSTRUCTION USING VERTICAL FISHEYE IMAGES: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    A. Berveglieri

    2016-06-01

    Full Text Available A preliminary study was conducted to assess a tree stem reconstruction technique with panoramic images taken with fisheye lenses. The concept is similar to the Structure from Motion (SfM technique, but the acquisition and data preparation rely on fisheye cameras to generate a vertical image sequence with height variations of the camera station. Each vertical image is rectified to four vertical planes, producing horizontal lateral views. The stems in the lateral view are rectified to the same scale in the image sequence to facilitate image matching. Using bundle adjustment, the stems are reconstructed, enabling later measurement and extraction of several attributes. The 3D reconstruction was performed with the proposed technique and compared with SfM. The preliminary results showed that the stems were correctly reconstructed by using the lateral virtual images generated from the vertical fisheye images and with the advantage of using fewer images and taken from one single station.

  20. A Study of Residual Image in Charged-Coupled Device

    Directory of Open Access Journals (Sweden)

    Ho Jin

    2005-12-01

    Full Text Available For an image sensor CCD, electrons can be trapped at the front-side Si-SiO_2 surface interface in a case of exceeding the full well by bright source. Residual images can be made by the electrons remaining in the interface. These residual images are seen in the front-side-illuminated CCDs especially. It is not easy to find a quantitative analysis for this phenomenon in the domestic reports, although it is able to contaminate observation data. In this study, we find residual images in dark frames which were obtained from the front-side-illuminated CCD at Mt. Lemmon Optical Astronomy Observatory (LOAO, and analyze the effect to contaminated observation data by residual charges.

  1. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  2. Arthroscopic repair of massive contracted rotator cuff tears: aggressive release with anterior and posterior interval slides do not improve cuff healing and integrity.

    Science.gov (United States)

    Kim, Sung-Jae; Kim, Sung-Hwan; Lee, Su-Keon; Seo, Jae-Wan; Chun, Yong-Min

    2013-08-21

    Few studies of large-to-massive contracted rotator cuff tears have examined the arthroscopic complete repair obtained by a posterior interval slide and whether the clinical outcomes or structural integrity achieved are better than those after partial repair without the posterior interval slide. The study included forty-one patients with large-to-massive contracted rotator cuff tears, not amenable to complete repair with margin convergence alone. The patients underwent either arthroscopic complete repair with a posterior interval slide and side-to-side repair of the interval slide edge (twenty-two patients; Group P) or partial repair with margin convergence (nineteen patients; Group M). The patient assignment was not randomized. The Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) score, University of California at Los Angeles (UCLA) shoulder score, and range of motion were used to compare the functional outcomes. Preoperative and six-month postoperative magnetic resonance arthrography (MRA) images were compared within or between groups. At the two-year follow-up evaluation, the SST, ASES score, UCLA score, and range of motion had significantly improved (p repair group with an aggressive release had no better clinical or structural outcomes compared with the partial repair group with margin convergence alone for large-to-massive contracted rotator cuff tears. In addition, the complete repair group had a 91% retear rate and a greater defect on follow-up MRA images. Even though this study had a relatively short-term follow-up, a complete repair of large-to-massive contracted rotator cuff tears, with an aggressive release such as posterior interval slide, may not have an increased benefit compared with partial repair without posterior interval slide.

  3. A Comparative Study on Diagnostic Accuracy of Colour Coded Digital Images, Direct Digital Images and Conventional Radiographs for Periapical Lesions – An In Vitro Study

    Science.gov (United States)

    Mubeen; K.R., Vijayalakshmi; Bhuyan, Sanat Kumar; Panigrahi, Rajat G; Priyadarshini, Smita R; Misra, Satyaranjan; Singh, Chandravir

    2014-01-01

    Objectives: The identification and radiographic interpretation of periapical bone lesions is important for accurate diagnosis and treatment. The present study was undertaken to study the feasibility and diagnostic accuracy of colour coded digital radiographs in terms of presence and size of lesion and to compare the diagnostic accuracy of colour coded digital images with direct digital images and conventional radiographs for assessing periapical lesions. Materials and Methods: Sixty human dry cadaver hemimandibles were obtained and periapical lesions were created in first and second premolar teeth at the junction of cancellous and cortical bone using a micromotor handpiece and carbide burs of sizes 2, 4 and 6. After each successive use of round burs, a conventional, RVG and colour coded image was taken for each specimen. All the images were evaluated by three observers. The diagnostic accuracy for each bur and image mode was calculated statistically. Results: Our results showed good interobserver (kappa > 0.61) agreement for the different radiographic techniques and for the different bur sizes. Conventional Radiography outperformed Digital Radiography in diagnosing periapical lesions made with Size two bur. Both were equally diagnostic for lesions made with larger bur sizes. Colour coding method was least accurate among all the techniques. Conclusion: Conventional radiography traditionally forms the backbone in the diagnosis, treatment planning and follow-up of periapical lesions. Direct digital imaging is an efficient technique, in diagnostic sense. Colour coding of digital radiography was feasible but less accurate however, this imaging technique, like any other, needs to be studied continuously with the emphasis on safety of patients and diagnostic quality of images. PMID:25584318

  4. Study of CT image texture using deep learning techniques

    Science.gov (United States)

    Dutta, Sandeep; Fan, Jiahua; Chevalier, David

    2018-03-01

    For CT imaging, reduction of radiation dose while improving or maintaining image quality (IQ) is currently a very active research and development topic. Iterative Reconstruction (IR) approaches have been suggested to be able to offer better IQ to dose ratio compared to the conventional Filtered Back Projection (FBP) reconstruction. However, it has been widely reported that often CT image texture from IR is different compared to that from FBP. Researchers have proposed different figure of metrics to quantitate the texture from different reconstruction methods. But there is still a lack of practical and robust method in the field for texture description. This work applied deep learning method for CT image texture study. Multiple dose scans of a 20cm diameter cylindrical water phantom was performed on Revolution CT scanner (GE Healthcare, Waukesha) and the images were reconstructed with FBP and four different IR reconstruction settings. The training images generated were randomly allotted (80:20) to a training and validation set. An independent test set of 256-512 images/class were collected with the same scan and reconstruction settings. Multiple deep learning (DL) networks with Convolution, RELU activation, max-pooling, fully-connected, global average pooling and softmax activation layers were investigated. Impact of different image patch size for training was investigated. Original pixel data as well as normalized image data were evaluated. DL models were reliably able to classify CT image texture with accuracy up to 99%. Results show that the deep learning techniques suggest that CT IR techniques may help lower the radiation dose compared to FBP.

  5. Modeling digital breast tomosynthesis imaging systems for optimization studies

    Science.gov (United States)

    Lau, Beverly Amy

    Digital breast tomosynthesis (DBT) is a new imaging modality for breast imaging. In tomosynthesis, multiple images of the compressed breast are acquired at different angles, and the projection view images are reconstructed to yield images of slices through the breast. One of the main problems to be addressed in the development of DBT is the optimal parameter settings to obtain images ideal for detection of cancer. Since it would be unethical to irradiate women multiple times to explore potentially optimum geometries for tomosynthesis, it is ideal to use a computer simulation to generate projection images. Existing tomosynthesis models have modeled scatter and detector without accounting for oblique angles of incidence that tomosynthesis introduces. Moreover, these models frequently use geometry-specific physical factors measured from real systems, which severely limits the robustness of their algorithms for optimization. The goal of this dissertation was to design the framework for a computer simulation of tomosynthesis that would produce images that are sensitive to changes in acquisition parameters, so an optimization study would be feasible. A computer physics simulation of the tomosynthesis system was developed. The x-ray source was modeled as a polychromatic spectrum based on published spectral data, and inverse-square law was applied. Scatter was applied using a convolution method with angle-dependent scatter point spread functions (sPSFs), followed by scaling using an angle-dependent scatter-to-primary ratio (SPR). Monte Carlo simulations were used to generate sPSFs for a 5-cm breast with a 1-cm air gap. Detector effects were included through geometric propagation of the image onto layers of the detector, which were blurred using depth-dependent detector point-spread functions (PRFs). Depth-dependent PRFs were calculated every 5-microns through a 200-micron thick CsI detector using Monte Carlo simulations. Electronic noise was added as Gaussian noise as a

  6. Detection of pulmonary nodules on lung X-ray images. Studies on multi-resolutional filter and energy subtraction images

    International Nuclear Information System (INIS)

    Sawada, Akira; Sato, Yoshinobu; Kido, Shoji; Tamura, Shinichi

    1999-01-01

    The purpose of this work is to prove the effectiveness of an energy subtraction image for the detection of pulmonary nodules and the effectiveness of multi-resolutional filter on an energy subtraction image to detect pulmonary nodules. Also we study influential factors to the accuracy of detection of pulmonary nodules from viewpoints of types of images, types of digital filters and types of evaluation methods. As one type of images, we select an energy subtraction image, which removes bones such as ribs from the conventional X-ray image by utilizing the difference of X-ray absorption ratios at different energy between bones and soft tissue. Ribs and vessels are major causes of CAD errors in detection of pulmonary nodules and many researches have tried to solve this problem. So we select conventional X-ray images and energy subtraction X-ray images as types of images, and at the same time select ∇ 2 G (Laplacian of Guassian) filter, Min-DD (Minimum Directional Difference) filter and our multi-resolutional filter as types of digital filters. Also we select two evaluation methods and prove the effectiveness of an energy subtraction image, the effectiveness of Min-DD filter on a conventional X-ray image and the effectiveness of multi-resolutional filter on an energy subtraction image. (author)

  7. The role of key image notes in CT imaging study interpretation.

    Science.gov (United States)

    Fan, Shu-Feng; Xu, Zhe; He, Hai-Qing; Ding, Jian-Rong; Teng, Gao-Jun

    2011-04-01

    The objective of the study was to investigate the clinical effects of CT key image notes (KIN) in the interpretation of a CT image study. All experiments were approved by the ethics committee of the local district. Six experienced radiologists were equally divided into routine reporting (RR) group and KIN reporting (KIN) group. CT scans of each 100 consecutive cases before and after using KIN technique were randomly selected, and the reports were made by group RR and KIN, respectively. All the reports were again reviewed 3 months later by both groups. All the results with using or not using KIN were interpreted and reinterpreted after 3 months by six clinicians, who were experienced in picture archiving and communication system (PACS) applications and were equally divided into the clinical routine report group and the clinical KIN report group, respectively. The results were statistically analyzed; the time used in making a report, the re-reading time 3 months later, and the consistency of imaging interpretation were determined and compared between groups. After using KIN technique, the time used in making a report was significantly increased (8.77 ± 5.27 vs. 10.53 ± 5.71 min, P < 0.05), the re-reading time was decreased (5.23 ± 2.54 vs. 4.99 ± 1.70 min, P < 0.05), the clinical interpretation and reinterpretation time after 3 months were decreased, and the consistency of the interpretation, reinterpretation between different doctors in different time was markedly improved (P < 0.01). CT report with KIN technique in PACS can significantly improve the consistency of the interpretation and efficiency in routine clinical work.

  8. Experimental study of bubbly flow using image processing techniques

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Yucheng, E-mail: ycfu@vt.edu; Liu, Yang, E-mail: liu130@vt.edu

    2016-12-15

    This paper presents an experimental study of bubbly flows at relatively high void fractions using an advanced image processing method. Bubble overlapping is a common problem in such flows and the past studies often treat the overlapping bubbles as a whole, which introduces considerable measurement uncertainties. In this study, a hybrid method combining intersection point detection and watershed segmentation is used to separate the overlapping bubbles. In order to reconstruct bubbles from separated segments, a systematic procedure is developed which can preserve more features captured in the raw image compared to the simple ellipse fitting method. The distributions of void fraction, interfacial area concentration, number density and velocity are obtained from the extracted bubble information. High-speed images of air-water bubbly flows are acquired and processed for eight test runs conducted in a 30 mm × 10 mm rectangular channel. The developed image processing scheme can effectively separate overlapping bubbles and the results compare well with the measurements by the gas flow meter and double-sensor conductivity probe. The development of flows in transverse and mainstream directions are analyzed and compared with the prediction made by the one-dimensional interfacial area transport equation (IATE) and the bubble number density transport equation.

  9. A pilot study of regenerative therapy using controlled release of recombinant human fibroblast growth factor for patients with pre-collapse osteonecrosis of the femoral head.

    Science.gov (United States)

    Kuroda, Yutaka; Asada, Ryuta; So, Kazutaka; Yonezawa, Atsushi; Nankaku, Manabu; Mukai, Kumi; Ito-Ihara, Toshiko; Tada, Harue; Yamamoto, Michio; Murayama, Toshinori; Morita, Satoshi; Tabata, Yasuhiko; Yokode, Masayuki; Shimizu, Akira; Matsuda, Shuichi; Akiyama, Haruhiko

    2016-08-01

    We evaluated the safety and clinical outcomes of a single local administration of gelatin hydrogel impregnated with recombinant human fibroblast growth factor (rhFGF)-2 for the treatment of the precollapse stage of osteonecrosis of the femoral head (ONFH). Patients with ONFH (precollapse stage ≤2) received a single local administration of 800 μg of rhFGF-2-impregnated gelatin hydrogel and were followed up for one year. The surgery was performed using a minimally invasive technique involving a 1-cm skin incision, and walking was allowed from day one postoperatively. The primary outcomes included occurrence of adverse events and complications. The secondary outcomes included changes in the Harris hip scores, visual analog scale for pain scores, University of California, Los Angeles (UCLA) activity scores, and radiological images. We included ten patients, of which five experienced 14 adverse events, including one complication from spinal anesthesia. However, patients completely recovered from all adverse events. The mean clinical scores significantly improved by one year postoperatively compared with the pre-operative scores (before vs. after: visual analog score for pain, 21.2 vs. 5.3 mm; UCLA activity score, 5.5 vs. 6.6; Harris hip score, 81.0 vs. 96.9 points). There was only one case of femoral head collapse; however, this occurred in a hip with extensive necrosis. Stage progression and collapse did not occur in the other nine cases. Computed tomography confirmed bone regeneration in the femoral heads. Clinical application of rhFGF-2-impregnated gelatin hydrogel for patients with precollapse ONFH was feasible and safe.

  10. Studies of the body image in various psychological approaches

    Directory of Open Access Journals (Sweden)

    Natalia A. Kaminskaya

    2015-09-01

    Full Text Available The paper aims to systematize modern concepts of body image and body scheme. For the analysis of theoretical models the following criteria were allocated: explication of the mechanism underlying the formation and restructuring of body image, development of certain aspects of body image which are explained by the presented concepts. Separately the issue of the difference between the body scheme and the body image is discussed that seems relevant in connection with the specific features of the neural mechanisms of body image. In the study of the phenomenological level of bodily experience the assumption that the body scheme is fragmented and has no hierarchical structure is considered. Significant differences in viewing basic mechanisms of developing the body image associated with attention to various bodily phenomena are showed. Psychodynamic, cognitive, socio-cultural, feminist and interdisciplinary approaches are analyzed, which permitted to identify mechanisms of integration-differentiation, cognitive generalization and internalization-introjection. The analysis suggests the consideration of the body image in the context of issues on the appropriation of the body. If person is considered as a tool for shaping and maintening integration of mental processes, the patterns of interconnected and interdependent changes in the processes that occur in the construction of the image of the external situation and the body image acquires a special psychological meaning. It becomes necessary to allocate correctly the structure of the integrating object in which the subject is involved during the normal course of life, and in exceptional cases, i.e. in the presence of physical defects, the sudden change of appearance, etc. These development objects determine specific form of body image and its possible distortions.

  11. A study of spinal cord tumors by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gushiken, Isao; Nishihira, Takeshi; Nakasone, Tomohiro [Ryukyu Univ., Nishihara, Okinawa (Japan). School of Medicine; Takara, Hiroaki; Oshiro, Yutaka; Oshiro, Takashi; Isa, Makoto; Kinjo, Yukio; Ibaraki, Kunio

    1989-10-01

    We studied 17 cases of spinal cord tumors using magnetic resonance imaging. According to the intensity of image and histological feature of spinal cord tumors, we identified two groups in T2 weighted imaging. One was a hypointensity group showing cystic or vascular tumors, and the other was hyperintensity group of solid tumors. Preoperative images of swelling, narrowing, deviation of the spinal cord were remained after the operations. Grafted free fatty tissue for the prevention of adhesion was recognized well also after the operation. Postoperative imagings sometime showed pseudo-deviation of the spinal cord which was easy to be mistaken as the remains of tumors and narrowing of the spinal cord. In conclusion, the magnetic resonance imaging makes very early detection of spinal cord tumors possible, and it is valuable for a diagnosis of the spinal cord tumor associated with brain tumor. (author).

  12. A study of spinal cord tumors by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Gushiken, Isao; Nishihira, Takeshi; Nakasone, Tomohiro; Takara, Hiroaki; Oshiro, Yutaka; Oshiro, Takashi; Isa, Makoto; Kinjo, Yukio; Ibaraki, Kunio.

    1989-01-01

    We studied 17 cases of spinal cord tumors using magnetic resonance imaging. According to the intensity of image and histological feature of spinal cord tumors, we identified two groups in T2 weighted imaging. One was a hypointensity group showing cystic or vascular tumors, and the other was hyperintensity group of solid tumors. Preoperative images of swelling, narrowing, deviation of the spinal cord were remained after the operations. Grafted free fatty tissue for the prevention of adhesion was recognized well also after the operation. Postoperative imagings sometime showed pseudo-deviation of the spinal cord which was easy to be mistaken as the remains of tumors and narrowing of the spinal cord. In conclusion, the magnetic resonance imaging makes very early detection of spinal cord tumors possible, and it is valuable for a diagnosis of the spinal cord tumor associated with brain tumor. (author)

  13. Technical characterization by image analysis: an automatic method of mineralogical studies

    International Nuclear Information System (INIS)

    Oliveira, J.F. de

    1988-01-01

    The application of a modern method of image analysis fully automated for the study of grain size distribution modal assays, degree of liberation and mineralogical associations is discussed. The image analyser is interfaced with a scanning electron microscope and an energy dispersive X-rays analyser. The image generated by backscattered electrons is analysed automatically and the system has been used in accessment studies of applied mineralogy as well as in process control in the mining industry. (author) [pt

  14. MR imaging studies of multiple myeloma in the vertebral column

    International Nuclear Information System (INIS)

    Albert, S.; Leeds, N.E.

    1990-01-01

    This paper studies the sensitivity and characteristics of MR imaging in the diagnosis of myeloma in the vertebral column. The cervical, thoracic, and lumbar spines of 12 patients with known multiple myeloma were imaged with small flip angle, fast gradient-echo, proton-density (FPD) as well as spin-echo T1-weighted, T2-weighted, and intermediate (SE 2,000/20-30) imaging. The FPD images were acquired with pulse sequence gradient recalled acquisition in a steady state at a magnetic field strength of 1.5T with use of a license-plate and a circular surface coil

  15. Does use of a PACS increase the number of images per study? A case study in ultrasound.

    Science.gov (United States)

    Horii, Steven; Nisenbaum, Harvey; Farn, James; Coleman, Beverly; Rowling, Susan; Langer, Jill; Jacobs, Jill; Arger, Peter; Pinheiro, Lisa; Klein, Wendy; Reber, Michele; Iyoob, Christopher

    2002-03-01

    The purpose of this study was to determine if the use of a picture archiving and communications system (PACS) in ultrasonography increased the number of images acquired per examination. The hypothesis that such an increase does occur was based on anecdotal information; this study sought to test the hypothesis. A random sample of all ultrasound examination types was drawn from the period 1998 through 1999. The ultrasound PACS in use (ACCESS; Kodak Health Information Systems, Dallas, TX) records the number of grayscale and color images saved as part of each study. Each examination in the sample was checked in the ultrasound PACS database,.and the number of grayscale and color images was recorded. The comparison film-based sample was drawn from the period 1994 through 1995. The number of examinations of each type selected was based on the overall statistics of the section; that is, the sample was designed to represent the approximate frequency with which the various examination types are done. For film-based image counts, the jackets were retrieved, and the number of grayscale and color images were counted. The number of images obtained per examination (for most examinations) in ultrasound increased with PACS use. This was more evident with some examination types (eg, pelvis). This result, however, has to be examined for possible systematic biases because ultrasound practice has changed over the time since the authors stopped using film routinely. The use of PACS in ultrasonography was not associated with an increase in the number of images per examination based solely on the use of PACS, with the exception of neonatal head studies. Increases in the number of images per study was otherwise associated with examinations for which changes in protocols resulted in the increased image counts.

  16. Comparison of the perceived image quality between two digital imaging systems for neonatal bedside radiography – A case study

    International Nuclear Information System (INIS)

    Zyl, S.A. van; Kekana, R.M.

    2015-01-01

    Background: Chest X-rays are performed daily in the neonatal intensive care and high care units. The skill of the radiographer is critical for obtaining the best image quality and limiting the patient's radiation exposure. The literature states that indirect flat panel detectors produce images of superior quality in comparison to computed radiography systems. At Steve Biko Academic Hospital a decision was made to revert from the direct digital radiography (DR) system to the computed radiography (CR) system, due to poor image quality experienced. Method: The case study objective was to conduct a comparative analysis describing key technical factors contributing to image quality. The analysis entailed retrospectively comparing the images obtained during 2010 and 2011. An image analysis form was utilised in evaluating the technical aspects of the image. A total of 160 images were viewed by 16 participants sampled from the radiography, radiology and paediatric departments. The participants were asked to re-evaluate two of their allotted images after five days to determine their reliability. Results: Findings were that the DR system provides significantly better image quality than the CR system (p < 0.05) for all the technical factors evaluated. However technical improvements are recommended. A wide variance in intra-observer reliability was also found. Conclusion: This case study demonstrated that DR images were considered to be superior to CR images. Recommendations include: a standardised technique for imaging the neonates; optimisation of the imaging software for the digital detectors, improved feedback systems in terms of exposure index values, and the training of radiographers and referring physicians in technical image analysis. - Highlights: • DR system provides better image quality than the CR system for all technical factors evaluated. • The average values obtained from the VAS showed that the DR system still needs to be optimised. • There is need

  17. Functional MRI studies of human vision on a clinical imager

    International Nuclear Information System (INIS)

    George, J.S.; Lewine, J.D.; Aine, C.J.; van Hulsteyn, D.; Wood, C.C.; Sanders, J.; Maclin, E.; Belliveau, J.W.; Caprihan, A.

    1992-01-01

    During the past decade, Magnetic Resonance Imaging (MRI) has become the method of choice for imaging the anatomy of the human brain. Recently, Belliveau and colleagues have reported the use of echo planar magnetic resonance imaging (EPI) to image patterns of neural activity. Here, we report functional MR imaging in response to visual stimulation without the use of contrast agents, and without the extensive hardware modifications required for EPI. Regions of activity were observed near the expected locations of V1, V2 and possibly V3 and another active region was observed near the parietal-occipital sulcus on the superior surface of the cerebrum. These locations are consistent with sources observed in neuromagnetic studies of the human visual response

  18. Study of quality perception in medical images based on comparison of contrast enhancement techniques in mammographic images

    Science.gov (United States)

    Matheus, B.; Verçosa, L. B.; Barufaldi, B.; Schiabel, H.

    2014-03-01

    With the absolute prevalence of digital images in mammography several new tools became available for radiologist; such as CAD schemes, digital zoom and contrast alteration. This work focuses in contrast variation and how the radiologist reacts to these changes when asked to evaluated image quality. Three contrast enhancing techniques were used in this study: conventional equalization, CCB Correction [1] - a digitization correction - and value subtraction. A set of 100 images was used in tests from some available online mammographic databases. The tests consisted of the presentation of all four versions of an image (original plus the three contrast enhanced images) to the specialist, requested to rank each one from the best up to worst quality for diagnosis. Analysis of results has demonstrated that CCB Correction [1] produced better images in almost all cases. Equalization, which mathematically produces a better contrast, was considered the worst for mammography image quality enhancement in the majority of cases (69.7%). The value subtraction procedure produced images considered better than the original in 84% of cases. Tests indicate that, for the radiologist's perception, it seems more important to guaranty full visualization of nuances than a high contrast image. Another result observed is that the "ideal" scanner curve does not yield the best result for a mammographic image. The important contrast range is the middle of the histogram, where nodules and masses need to be seen and clearly distinguished.

  19. Biochemistry Instrumentation Core Technology Center

    Data.gov (United States)

    Federal Laboratory Consortium — The UCLA-DOE Biochemistry Instrumentation Core Facility provides the UCLA biochemistry community with easy access to sophisticated instrumentation for a wide variety...

  20. A study on consciousness of adolescent girls about their body image

    Directory of Open Access Journals (Sweden)

    Swati Dixit

    2011-01-01

    Full Text Available Background: Perceived body image is an important potential predictor of nutritional status. Body image misconception during adolescence is unexplored field in Indian girls. Objectives: To study the consciousness of adolescent girls about their body image. Materials and Methods: This multistage observational study was conducted on 586 adolescent girls of age 10-19 years in Lucknow district (151 from rural, 150 from slum, and 286 from urban area of Uttar Pradesh, India. Information on desired and actual body size was collected with the help of predesigned questionnaire. Results: 20.5% of studied girls show aspiration to become thin, who already perceived their body image as too thin. 73.4% adolescent girls were satisfied with their body image, while 26.6% were dissatisfied. The dissatisfaction was higher among girls of urban (30.2% and slum (40.0% areas in comparison to rural (22.5% area. Percentage of satisfied girls was less in the 13-15 years (69.9% age groups in comparison to 10-12 years (76.5% and 16-19 years (76.4%. Among girls satisfied with their body image, 32.8% girls were found underweight, and 38.4% were stunted. Underweight girls (42.1% and stunted girls (64.9% were higher in number within satisfied girls of slum area. Among all of these adolescent girls, 32.8% of girls had overestimated their weight, while only 4.9% of girls had underestimated their weight. Conclusions: This study concludes that desire to become thin is higher in adolescent girls, even in those who already perceived their body image as too thin.

  1. Scoring of treatment-related late effects in prostate cancer

    International Nuclear Information System (INIS)

    Livsey, Jacqueline E.; Routledge, Jacqueline; Burns, Meriel; Swindell, Rick; Davidson, Susan E.; Cowan, Richard A.; Logue, John P.; Wylie, James P.

    2002-01-01

    Background and purpose: To assess the correlation between different general and organ specific quality of life and morbidity scoring methods in a cohort of men treated with radical radiotherapy for prostate cancer. Materials and methods: Men who had been treated with radical radiotherapy (50 Gy in 16 fractions over 21 days) for localized prostate cancer more than 3 years previously and who had no evidence of recurrent disease were invited to take part in the study. A total of 101 of 135 invited patients agreed and completed LENT/SOMA, UCLA Prostate Cancer Index, and 36 item RAND Health survey questionnaires. Results: The patients had comparable results with other published series with respect to the UCLA and SF-36 indices. There was significant correlation between the corresponding parts of the UCLA and LENT/SOMA scales (P<0.0005). However, for the same symptoms, a patient tended to score lower (worse) on the UCLA scale in comparison to LENT/SOMA. The relationship between the average LENT/SOMA score and maximum score was also not straightforward with each set of data revealing different information. Conclusions: The LENT/SOMA questions were, in the main, more wide-ranging and informative than the UCLA index. It is helpful to give both the overall and maximum LENT/SOMA scores to most efficiently use all of the data. There may need to be a further LENT/SOMA question to allow both symptoms of tenesmus and faecal urgency to be fully addressed

  2. Study on the abnormal image appeared in radiographs of welds, 3

    International Nuclear Information System (INIS)

    Hayashi, Morihiro; Sugimura, Seiichi; Umemura, Kunio; Imamura, Senji; Kanno, Munekazu.

    1984-01-01

    On the abnormal images arising at times in the X-ray radiographs of austenitic stainless steel welded parts, the cause of occurrence was clarified before. In this study, the authors made the welded parts of austenitic stainless steel SUS 304 and SUS 316 with abnormal images of different clearness by making heat input into respective layers of welds large or small, and compared the static and dynamic strength. Moreover, the relation of the form of abnormal images in radiographs to metal structures was studied. The welding method employed was TIG welding and submerged arc welding. The images of X-ray radiographs and the metal structures of the welded parts tested are shown. The mechanical strength test was carried out by tension, bending and impact. Also fatigue test was performed. In the welded parts of SUS 304 and SUS 316, even if abnormal images appeared in radiographs, when sound welding was made, they possessed sufficient strength statically and dynamically. In the macroscopic and microscopic cross-sectional structures of the welded parts with remarkable abnormal images, defect was not observed at all. The cause of abnormal image appearance is the diffraction of X-ray. (Kako, I.)

  3. Retail store image in emerging markets: An initial study among Chinese retailers

    DEFF Research Database (Denmark)

    Hansen, Kåre

    differences regarding store characteristics, purchasing behavior, and supplier selection criteria among the three identified store image segments are revealed. The implications of these findings for practitioners and for future research on store image in emerging markets are highlighted....... their stores to defend and sustain the image (i.e. retailers' perspective). Here Chinese food retailing is used as an example of emerging markets. The study finds three unique store images, corresponding to up-market, middle-range, and down-market store segments. Contrasting the two studies, significant...

  4. An Ecometric Study of Recent Microfossils using High-throughput Imaging

    Science.gov (United States)

    Elder, L. E.; Hull, P. M.; Hsiang, A. Y.; Kahanamoku, S.

    2016-02-01

    The era of Big Data has ushered in the potential to collect population level information in a manageable time frame. Taxon-free morphological trait analysis, referred to as ecometrics, can be used to examine and compare ecological dynamics between communities with entirely different species compositions. Until recently population level studies of morphology were difficult because of the time intensive task of collecting measurements. To overcome this, we implemented advances in imaging technology and created software to automate measurements. This high-throughput set of methods collects assemblage-scale data, with methods tuned to foraminiferal samples (e.g., light objects on a dark background). Methods include serial focused dark-field microscopy, custom software (Automorph) to batch process images, extract 2D and 3D shape parameters and frames, and implement landmark-free geometric morphometric analyses. Informatics pipelines were created to store, catalog and share images through the Yale Peabody Museum(YPM; peabody.yale.edu). We openly share software and images to enhance future data discovery. In less than a year we have generated over 25TB of high resolution semi 3D images for this initial study. Here, we take the first step towards developing ecometric approaches for open ocean microfossil communities with a calibration study of community shape in recent sediments. We will present an overview of the `shape' of modern planktonic foraminiferal communities from 25 Atlantic core top samples (23 sites in the North and Equatorial Atlantic; 2 sites in the South Atlantic). In total, more than 100,000 microfossils and fragments were imaged from these sites' sediment cores, an unprecedented morphometric sample set. Correlates of community shape, including diversity, temperature, and latitude, will be discussed. These methods have also been applied to images of limpets and fish teeth to date, and have the potential to be used on modern taxa to extract meaningful

  5. Sensitivity study of voxel-based PET image comparison to image registration algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Yip, Stephen, E-mail: syip@lroc.harvard.edu; Chen, Aileen B.; Berbeco, Ross [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Aerts, Hugo J. W. L. [Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 and Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2014-11-01

    Purpose: Accurate deformable registration is essential for voxel-based comparison of sequential positron emission tomography (PET) images for proper adaptation of treatment plan and treatment response assessment. The comparison may be sensitive to the method of deformable registration as the optimal algorithm is unknown. This study investigated the impact of registration algorithm choice on therapy response evaluation. Methods: Sixteen patients with 20 lung tumors underwent a pre- and post-treatment computed tomography (CT) and 4D FDG-PET scans before and after chemoradiotherapy. All CT images were coregistered using a rigid and ten deformable registration algorithms. The resulting transformations were then applied to the respective PET images. Moreover, the tumor region defined by a physician on the registered PET images was classified into progressor, stable-disease, and responder subvolumes. Particularly, voxels with standardized uptake value (SUV) decreases >30% were classified as responder, while voxels with SUV increases >30% were progressor. All other voxels were considered stable-disease. The agreement of the subvolumes resulting from difference registration algorithms was assessed by Dice similarity index (DSI). Coefficient of variation (CV) was computed to assess variability of DSI between individual tumors. Root mean square difference (RMS{sub rigid}) of the rigidly registered CT images was used to measure the degree of tumor deformation. RMS{sub rigid} and DSI were correlated by Spearman correlation coefficient (R) to investigate the effect of tumor deformation on DSI. Results: Median DSI{sub rigid} was found to be 72%, 66%, and 80%, for progressor, stable-disease, and responder, respectively. Median DSI{sub deformable} was 63%–84%, 65%–81%, and 82%–89%. Variability of DSI was substantial and similar for both rigid and deformable algorithms with CV > 10% for all subvolumes. Tumor deformation had moderate to significant impact on DSI for progressor

  6. Study on super-resolution three-dimensional range-gated imaging technology

    Science.gov (United States)

    Guo, Huichao; Sun, Huayan; Wang, Shuai; Fan, Youchen; Li, Yuanmiao

    2018-04-01

    Range-gated three dimensional imaging technology is a hotspot in recent years, because of the advantages of high spatial resolution, high range accuracy, long range, and simultaneous reflection of target reflectivity information. Based on the study of the principle of intensity-related method, this paper has carried out theoretical analysis and experimental research. The experimental system adopts the high power pulsed semiconductor laser as light source, gated ICCD as the imaging device, can realize the imaging depth and distance flexible adjustment to achieve different work mode. The imaging experiment of small imaging depth is carried out aiming at building 500m away, and 26 group images were obtained with distance step 1.5m. In this paper, the calculation method of 3D point cloud based on triangle method is analyzed, and 15m depth slice of the target 3D point cloud are obtained by using two frame images, the distance precision is better than 0.5m. The influence of signal to noise ratio, illumination uniformity and image brightness on distance accuracy are analyzed. Based on the comparison with the time-slicing method, a method for improving the linearity of point cloud is proposed.

  7. An image quality comparison study between XVI and OBI CBCT systems.

    Science.gov (United States)

    Kamath, Srijit; Song, William; Chvetsov, Alexei; Ozawa, Shuichi; Lu, Haibin; Samant, Sanjiv; Liu, Chihray; Li, Jonathan G; Palta, Jatinder R

    2011-02-04

    The purpose of this study is to evaluate and compare image quality characteristics for two commonly used and commercially available CBCT systems: the X-ray Volumetric Imager and the On-Board Imager. A commonly used CATPHAN image quality phantom was used to measure various image quality parameters, namely, pixel value stability and accuracy, noise, contrast to noise ratio (CNR), high-contrast resolution, low contrast resolution and image uniformity. For the XVI unit, we evaluated the image quality for four manufacturer-supplied protocols as a function of mAs. For the OBI unit, we did the same for the full-fan and half-fan scanning modes, which were respectively used with the full bow-tie and half bow-tie filters. For XVI, the mean pixel values of regions of interest were found to generally decrease with increasing mAs for all protocols, while they were relatively stable with mAs for OBI. Noise was slightly lower on XVI and was seen to decrease with increasing mAs, while CNR increased with mAs for both systems. For XVI and OBI, the high-contrast resolution was approximately limited by the pixel resolution of the reconstructed image. On OBI images, up to 6 and 5 discs of 1% and 0.5% contrast, respectively, were visible for a high mAs setting using the full-fan mode, while none of the discs were clearly visible on the XVI images for various mAs settings when the medium resolution reconstruction was used. In conclusion, image quality parameters for XVI and OBI have been quantified and compared for clinical protocols under various mAs settings. These results need to be viewed in the context of a recent study that reported the dose-mAs relationship for the two systems and found that OBI generally delivered higher imaging doses than XVI.

  8. Automated image analysis in the study of collagenous colitis

    DEFF Research Database (Denmark)

    Fiehn, Anne-Marie Kanstrup; Kristensson, Martin; Engel, Ulla

    2016-01-01

    PURPOSE: The aim of this study was to develop an automated image analysis software to measure the thickness of the subepithelial collagenous band in colon biopsies with collagenous colitis (CC) and incomplete CC (CCi). The software measures the thickness of the collagenous band on microscopic...... slides stained with Van Gieson (VG). PATIENTS AND METHODS: A training set consisting of ten biopsies diagnosed as CC, CCi, and normal colon mucosa was used to develop the automated image analysis (VG app) to match the assessment by a pathologist. The study set consisted of biopsies from 75 patients...

  9. Estudo prospectivo e comparativo dos resultados funcionais após reparo aberto e artroscópico das lesões do manguito rotador Prospective and comparative study on functional outcomes after open and arthroscopic repair of rotator cuff tears

    Directory of Open Access Journals (Sweden)

    Marco Antônio de Castro Veado

    2011-10-01

    compare occurrences of renewed tearing. METHODS: Sixty patients underwent operations performed by the same surgeon (29 via open surgery and 31 via arthroscopy, to repair complete rotator cuff tears. The procedures were performed at Hospital Governor Israel Pinheiro (HGIP and Mater Dei Hospital in Belo Horizonte, Minas Gerais, between August 2007 and February 2009. The patients were assessed functionally by means of the UCLA score before and after the operation, and magnetic resonance imaging was done before the operation. All the patients were reassessed at least 12 months after the operation, and an ultrasound examination was also performed at this time. RESULTS: Out of the 29 patients who underwent open surgery, 27 (93.1% presented good or excellent results, with a mean UCLA score of 32 after the operation. Their mean follow-up was 14 months. Three patients presented renewed tearing on ultrasound, of whom one remained asymptomatic. Out of the 31 patients who underwent arthroscopic procedures, 29 (93.5% presented good or excellent results, with a mean UCLA score of 33 after the operation. Their mean follow-up was 19 months. Two patients presented renewed tearing, of whom one remained asymptomatic and one evolved with loosening of an anchor, with an unsatisfactory result. CONCLUSION: The repairs on rotator cuff injuries presented good results by means of both open surgery and arthroscopy, with similar functional results in the two groups and similar rates of renewed tearing.

  10. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  11. Comparative study of image registration techniques for bladder video-endoscopy

    Science.gov (United States)

    Ben Hamadou, Achraf; Soussen, Charles; Blondel, Walter; Daul, Christian; Wolf, Didier

    2009-07-01

    Bladder cancer is widely spread in the world. Many adequate diagnosis techniques exist. Video-endoscopy remains the standard clinical procedure for visual exploration of the bladder internal surface. However, video-endoscopy presents the limit that the imaged area for each image is about nearly 1 cm2. And, lesions are, typically, spread over several images. The aim of this contribution is to assess the performance of two mosaicing algorithms leading to the construction of panoramic maps (one unique image) of bladder walls. The quantitative comparison study is performed on a set of real endoscopic exam data and on simulated data relative to bladder phantom.

  12. A Study on Consciousness of Adolescent Girls About Their Body Image

    Science.gov (United States)

    Dixit, Swati; Agarwal, GG; Singh, JV; Kant, Surya; Singh, Neelam

    2011-01-01

    Background: Perceived body image is an important potential predictor of nutritional status. Body image misconception during adolescence is unexplored field in Indian girls. Objectives: To study the consciousness of adolescent girls about their body image. Materials and Methods: This multistage observational study was conducted on 586 adolescent girls of age 10–19 years in Lucknow district (151 from rural, 150 from slum, and 286 from urban area) of Uttar Pradesh, India. Information on desired and actual body size was collected with the help of predesigned questionnaire. Results: 20.5% of studied girls show aspiration to become thin, who already perceived their body image as too thin. 73.4% adolescent girls were satisfied with their body image, while 26.6% were dissatisfied. The dissatisfaction was higher among girls of urban (30.2%) and slum (40.0%) areas in comparison to rural (22.5%) area. Percentage of satisfied girls was less in the 13–15 years (69.9%) age groups in comparison to 10–12 years (76.5%) and 16–19 years (76.4%). Among girls satisfied with their body image, 32.8% girls were found underweight, and 38.4% were stunted. Underweight girls (42.1%) and stunted girls (64.9%) were higher in number within satisfied girls of slum area. Among all of these adolescent girls, 32.8% of girls had overestimated their weight, while only 4.9% of girls had underestimated their weight. Conclusions: This study concludes that desire to become thin is higher in adolescent girls, even in those who already perceived their body image as too thin. PMID:22090673

  13. A Time of Flight Fast Neutron Imaging System Design Study

    Science.gov (United States)

    Canion, Bonnie; Glenn, Andrew; Sheets, Steven; Wurtz, Ron; Nakae, Les; Hausladen, Paul; McConchie, Seth; Blackston, Matthew; Fabris, Lorenzo; Newby, Jason

    2017-09-01

    LLNL and ORNL are designing an active/passive fast neutron imaging system that is flexible to non-ideal detector positioning. It is often not possible to move an inspection object in fieldable imager applications such as safeguards, arms control treaty verification, and emergency response. Particularly, we are interested in scenarios which inspectors do not have access to all sides of an inspection object, due to interfering objects or walls. This paper will present the results of a simulation-based design parameter study, that will determine the optimum system design parameters for a fieldable system to perform time-of-flight based imaging analysis. The imaging analysis is based on the use of an associated particle imaging deuterium-tritium (API DT) neutron generator to get the time-of-flight of radiation induced within an inspection object. This design study will investigate the optimum design parameters for such a system (e.g. detector size, ideal placement, etc.), as well as the upper and lower feasible design parameters that the system can expect to provide results within a reasonable amount of time (e.g. minimum/maximum detector efficiency, detector standoff, etc.). Ideally the final prototype from this project will be capable of using full-access techniques, such as transmission imaging, when the measurement circumstances allow, but with the additional capability of producing results at reduced accessibility.

  14. Imaging the Molecular Disk Orbiting the Twin Suns of V4046 Sgr

    Science.gov (United States)

    Rodriguez, David R.; Kastner, J. H.; Wilner, D. J.; Zuckerman, B.

    2009-05-01

    V4046 Sgr is a 12 Myr-old spectroscopic binary with a period of 2.4 days. At a distance of 73 pc (Torres et al. 2008), it is the second closest classical T Tauri star to the Earth after TW Hydra. Previously, rotational transitions of CO, HCO+, CN, and HCN were detected with the 30m IRAM telescope (Kastner et al. 2008). The double peaked CO profiles can be fit by a model invoking a Keplerian disk with outer radius of 250 AU that is viewed at an inclination of 35 degrees. The CO line profile was asymmetric, with the redshifted emission peak in both C-12 and C-13 brighter than the blueshifted peak. We have used the SMA to spatially resolve the J=2-1 CO emission line and the 230 GHz continuum. The CO channel maps show a disk consistent with Keplerian rotation. At the velocity of the redshifted emission peak, these observations reveal enhanced CO emission a few arcseconds to the southwest of the binary. A question arises as to whether this enhanced CO emission is associated with a third star in the system. According to the analysis of Tokovinin et al. (2006), the probability that a binary with a 2.4 day period has an associated tertiary star is essentially 100%. We searched archival Chandra and HST (ACS and NICMOS) images in the vicinity of V4046 Sgr to look for a star at the position of the enhanced CO emission. While there is a star in the HST ACS images approximately coincident with the enhanced CO emission, our preliminary analysis suggests that this star is not physically associated with V4046 Sgr. We will present a detailed discussion of the SMA results. This work has been partially supported by a NASA ADA grant to RIT and UCLA.

  15. Standardizing display conditions of diffusion-weighted images using concurrent b0 images. A multi-vendor multi-institutional study

    International Nuclear Information System (INIS)

    Sasaki, Makoto; Ida, Masahiro; Yamada, Kei; Watanabe, Yoshiyuki; Matsui, Mieko

    2007-01-01

    The purpose of this study was to establish a practical method that uses concurrent b0 images to standardize the display conditions for diffusion-weighted images (DWI) that vary among institutions and interpreters. Using identical parameters, we obtained DWI for 12 healthy volunteers at 4 institutions using 4 MRI scanners from 3 vendors. Three operators manually set the window width for the images equal to the signal intensity of the normal-appearing thalamus on b0 images and set the window level at half and then exported the images to 8-bit gray-scale images. We calculated the mean pixel values of the brain objects in the images and examined the variation among scanners, operators, and subjects. Following our method, the DWI of the 12 subjects obtained using the 4 different scanners had nearly identical contrast and brightness. The mean pixel values of the brain on the exported images among the operators and subjects were not significantly different, but we found a slight, significant difference among the scanners. Determining DWI display conditions by using b0 images is a simple and practical method to standardize window width and level for evaluating diffusion abnormalities and decreasing variation among institutions and operators. (author)

  16. Psychophysical studies of the performance of an image database retrieval system

    Science.gov (United States)

    Papathomas, Thomas V.; Conway, Tiffany E.; Cox, Ingemar J.; Ghosn, Joumana; Miller, Matt L.; Minka, Thomas P.; Yianilos, Peter N.

    1998-07-01

    We describe psychophysical experiments conducted to study PicHunter, a content-based image retrieval (CBIR) system. Experiment 1 studies the importance of using (a) semantic information, (2) memory of earlier input and (3) relative, rather than absolute, judgements of image similarity. The target testing paradigm is used in which a user must search for an image identical to a target. We find that the best performance comes from a version of PicHunter that uses only semantic cues, with memory and relative similarity judgements. Second best is use of both pictorial and semantic cues, with memory and relative similarity judgements. Most reports of CBIR systems provide only qualitative measures of performance based on how similar retrieved images are to a target. Experiment 2 puts PicHunter into this context with a more rigorous test. We first establish a baseline for our database by measuring the time required to find an image that is similar to a target when the images are presented in random order. Although PicHunter's performance is measurably better than this, the test is weak because even random presentation of images yields reasonably short search times. This casts doubt on the strength of results given in other reports where no baseline is established.

  17. Impact of the Parameter Variation on the Image Blurring in 3 T Magnetic Resonance Imaging: A Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Woo; Lee, Sang Hoon; Kim, Nam Kug; Cho, Kyung Sik; Lee, Jin Seong [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2013-04-15

    To evaluate the effects of the key imaging-parameter alterations on the four MR sequences in a phantom study. Magnetic resonance (MR) imaging was performed on a MR phantom with an 8-channel head coil by using a 3 T MR system. The images were obtained in the axial plane on four MR sequences [T1-weighted, T2-weighted, Proton-density, and 3 dimensional (3D) fast spin echo (FSE)] with controlled variations in the following key parameters: 1) echo train length (ETL), 2) repetition time (TR), and 3) echo time (TE). The image blurring was determined by the degree of the gradient angle; i.e., the blurring increased as the gradient angle decreases. The increasing ETL was observed to cause an increase in the image blurring on all pulse sequences with a statistical significance (p = 0.004) on the 3D FSE. Increasing the TR appeared to have no effect except a statistically significant decrease on the T1-weighted images (p = 0.011). Increasing TE showed no effect on the T1-weighted images (p = 0.932); however, it caused an increase of blurring on the proton density images (p = 0.016) as well as the T2-weighted images (p < 0.001), and a decrease on the 3D FSE (p = 0.001). To reduce the image blurring, short ETL and long TE for 3D FSE, long TR for T1-weighted images and short TE for proton-density and T2-weighted images should be applied.

  18. Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images

    International Nuclear Information System (INIS)

    Kadoya, Noriyuki; Nakajima, Yujiro; Saito, Masahide; Miyabe, Yuki; Kurooka, Masahiko; Kito, Satoshi; Fujita, Yukio; Sasaki, Motoharu; Arai, Kazuhiro; Tani, Kensuke; Yagi, Masashi; Wakita, Akihisa; Tohyama, Naoki; Jingu, Keiichi

    2016-01-01

    Purpose: To assess the accuracy of the commercially available deformable image registration (DIR) software for thoracic images at multiple institutions. Methods and Materials: Thoracic 4-dimensional (4D) CT images of 10 patients with esophageal or lung cancer were used. Datasets for these patients were provided by DIR-lab ( (dir-lab.com)) and included a coordinate list of anatomic landmarks (300 bronchial bifurcations) that had been manually identified. Deformable image registration was performed between the peak-inhale and -exhale images. Deformable image registration error was determined by calculating the difference at each landmark point between the displacement calculated by DIR software and that calculated by the landmark. Results: Eleven institutions participated in this study: 4 used RayStation (RaySearch Laboratories, Stockholm, Sweden), 5 used MIM Software (Cleveland, OH), and 3 used Velocity (Varian Medical Systems, Palo Alto, CA). The ranges of the average absolute registration errors over all cases were as follows: 0.48 to 1.51 mm (right-left), 0.53 to 2.86 mm (anterior-posterior), 0.85 to 4.46 mm (superior-inferior), and 1.26 to 6.20 mm (3-dimensional). For each DIR software package, the average 3-dimensional registration error (range) was as follows: RayStation, 3.28 mm (1.26-3.91 mm); MIM Software, 3.29 mm (2.17-3.61 mm); and Velocity, 5.01 mm (4.02-6.20 mm). These results demonstrate that there was moderate variation among institutions, although the DIR software was the same. Conclusions: We evaluated the commercially available DIR software using thoracic 4D-CT images from multiple centers. Our results demonstrated that DIR accuracy differed among institutions because it was dependent on both the DIR software and procedure. Our results could be helpful for establishing prospective clinical trials and for the widespread use of DIR software. In addition, for clinical care, we should try to find the optimal DIR procedure using thoracic 4D

  19. Correlation of early-phase 18F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    International Nuclear Information System (INIS)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju; Huang, Chin-Chang; Hsu, Wen-Chun; Yen, Tzu-Chen; Kung, Mei-Ping

    2012-01-01

    18 F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R 1 ) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R 1 images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R 1 and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R 1 images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R 1 . A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R 1 and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  20. Blind CT image quality assessment via deep learning strategy: initial study

    Science.gov (United States)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  1. Diagnostic ultrasound imaging for lateral epicondylalgia: a case-control study.

    Science.gov (United States)

    Heales, Luke James; Broadhurst, Nathan; Mellor, Rebecca; Hodges, Paul William; Vicenzino, Bill

    2014-11-01

    Lateral epicondylalgia (LE) is clinically diagnosed as pain over the lateral elbow that is provoked by gripping. Usually, LE responds well to conservative intervention; however, those who fail such treatment require further evaluation, including musculoskeletal ultrasound. Previous studies of musculoskeletal ultrasound have methodological flaws, such as lack of assessor blinding and failure to control for participant age, sex, and arm dominance. The purpose of this study was to assess the diagnostic use of blinded ultrasound imaging in people with clinically diagnosed LE compared with that in a control group matched for age, sex, and arm dominance. Participants (30 with LE and 30 controls) underwent clinical examination as the criterion standard test. Unilateral LE was defined as pain over the lateral epicondyle, which was provoked by palpation, resisted wrist and finger extension, and gripping. Controls without symptoms were matched for age, sex, and arm dominance. Ultrasound investigations were performed by two sonographers using a standardized protocol. Grayscale images were assessed for signs of tendon pathology and rated on a four-point ordinal scale. Power Doppler was used to assess neovascularity and rated on a five-point ordinal scale. The combination of grayscale and power Doppler imaging revealed an overall sensitivity of 90% and specificity of 47%. The positive and negative likelihood ratios for combined grayscale and power Doppler imaging were 1.69 and 0.21, respectively. Although ultrasound imaging helps confirm the absence of LE, when findings are negative for tendinopathic changes, the high prevalence of tendinopathic changes in pain-free controls challenges the specificity of the measure. The validity of ultrasound imaging to confirm tendon pathology in clinically diagnosed LE requires further study with strong methodology.

  2. Study of Brand Awareness and BrandImage of Starbucks

    OpenAIRE

    Rizwan, Muhammad; xian, Qin

    2008-01-01

    Abstract Date: September 1, 2008 Course: EFO705 Master Thesis International Marketing Tutor: Peter Dalin Authors: Muhammad Rizwan Qin Xian Title: Study of Brand Awareness and Brand Image of Starbucks Problem: To investigate to what extent the Swedish youths have brand awareness about the brand of Starbucks and what kind of brand perception of Starbucks as reflected by the brand association held in target customers’ memories (brand image). Purpos...

  3. A comparison of functional outcomes in patients undergoing revision arthroscopic repair of massive rotator cuff tears with and without arthroscopic suprascapular nerve release

    Directory of Open Access Journals (Sweden)

    Savoie III FH

    2016-10-01

    Full Text Available Felix H Savoie III,1 Mark Zunkiewicz,2 Larry D Field,2 William H Replogle,3 Michael J O’Brien1 1Tulane Institute of Sports Medicine, Tulane University School of Medicine, New Orleans, LA, USA; 2Mississippi Sports Medicine and Orthopaedic Center, Jackson, MS, USA; 3Department of Family Medicine, University of Mississippi Medical Center, Jackson, MS, USA Purpose: This study was designed to compare functional outcomes in patients undergoing revision repair of massive rotator cuff tears (retracted medial to the glenoid with Goutallier Grade 4 atrophy and concomitant release of the suprascapular nerve to a similar group of patients with Grade 3 atrophy undergoing revision rotator cuff repair (RTCR without nerve release. We hypothesized that patients undergoing nerve release would have more favorable functional outcomes as measured by the Modified University of California at Los Angeles shoulder rating scale (UCLA. Patients and methods: Twenty-two patients underwent revision repair of massive rotator cuff tears with release of the suprascapular nerve at the suprascapular notch. We compared total preoperative, postoperative, and change in UCLA score in these patients to a similar group of 22 patients undergoing revision RTCR without suprascapular nerve release. Additionally, UCLA subscores between the two groups were compared preoperatively and at final follow-up. Results: The average preoperative UCLA score in the nerve-release group was 7.91, and final follow-up average was 27.86; average 3.05 grades of strength were recovered. In the comparison group, average preoperative UCLA score was 11.77, and final follow-up average was 29.09; average 1.32 grades of strength were recovered. The average preoperative UCLA score was significantly worse in the nerve-release group (P=0.007. The average postoperative UCLA score was not significantly different (P=0.590 between the groups, indicating a better improvement in the nerve-release group with significantly

  4. Validating the 11-Item Revised University of California Los Angeles Scale to Assess Loneliness Among Older Adults: An Evaluation of Factor Structure and Other Measurement Properties.

    Science.gov (United States)

    Lee, Joonyup; Cagle, John G

    2017-11-01

    To examine the measurement properties and factor structure of the short version of the Revised University of California Los Angeles (R-UCLA) loneliness scale from the Health and Retirement Study (HRS). Based on data from 3,706 HRS participants aged 65 + who completed the 2012 wave of the HRS and its Psychosocial Supplement, the measurement properties and factorability of the R-UCLA were examined by conducting an exploratory factor analysis (EFA) and the confirmatory factor analysis (CFA) on randomly split halves. The average score for the 11-item loneliness scale was 16.4 (standard deviation: 4.5). An evaluation of the internal consistency produced a Cronbach's α of 0.87. Results from the EFA showed that two- and three-factor models were appropriate. However, based on the results of the CFA, only a two-factor model was determined to be suitable because there was a very high correlation between two factors identified in the three-factor model, available social connections and sense of belonging. This study provides important data on the properties of the 11-item R-UCLA scale by identifying a two-factor model of loneliness: feeling isolated and available social connections. Our findings suggest the 11-item R-UCLA has good factorability and internal reliability. Copyright © 2017 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  5. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States); Bender, H. A.; Wilcox, N. S. [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, New Mexico 87544 (United States)

    2010-01-15

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  6. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector.

    Science.gov (United States)

    Musumeci, P; Moody, J T; Scoby, C M; Gutierrez, M S; Bender, H A; Wilcox, N S

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  7. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    International Nuclear Information System (INIS)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S.; Bender, H. A.; Wilcox, N. S.

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  8. Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

    Energy Technology Data Exchange (ETDEWEB)

    Rompp, Andreas; Both, Jean-Pierre; Brunelle, Alain; Heeren, Ronald M.; Laprevote, Olivier; Prideaux, Brendan; Seyer, Alexandre; Spengler, Bernhard; Stoeckli, Markus; Smith, Donald F.

    2015-03-01

    Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common

  9. Study of photoconductor-based radiological image sensors

    International Nuclear Information System (INIS)

    Beaumont, Francois

    1989-01-01

    Because of the evolution of medical imaging techniques to digital Systems, it is necessary to replace radiological film which has many drawbacks, by a detector quite as efficient and quickly giving a digitizable signal. The purpose of this thesis is to find new X-ray digital imaging processes using photoconductor materials such as amorphous selenium. After reviewing the principle of direct radiology and functions to be served by the X-ray sensor (i.e. detection, memory, assignment, visualization), we explain specification. We especially show the constraints due to the object to be radiographed (condition of minimal exposure), and to the reading signal (electronic noise detection associated with a reading frequency). As a result of this study, a first photoconductor sensor could be designed. Its principle is based on photo-carrier trapping at dielectric-photoconductor structure interface. The reading System needs the scanning of a laser beam upon the sensor surface. The dielectric-photoconductor structure enabled us to estimate the possibilities offered by the sensor and to build a complete x-ray imaging System. The originality of thermo-dielectric sensor, that was next studied, is to allow a thermal assignment reading. The chosen System consists in varying the ferroelectric polymer capacity whose dielectric permittivity is weak at room temperature. The thermo-dielectric material was studied by thermal or Joule effect stimulation. During our experiments, trapping was found in a sensor made of amorphous selenium between two electrodes. This new effect was performed and enabled us to expose a first interpretation. Eventually, the comparison of these new sensor concepts with radiological film shows the advantage of the proposed solution. (author) [fr

  10. Collagenous sprue cross-sectional imaging: a comparative blinded study.

    Science.gov (United States)

    Al-Bawardy, Badr; Sheedy, Shannon P; Herberts, Michelle B; Murray, Joseph A; Rubio-Tapia, Alberto; Rajan, Elizabeth; Bruining, David H; Hansel, Stephanie L; Barlow, John M; Fletcher, Joel G; Fidler, Jeff L

    2017-02-01

    Collagenous sprue (CS) is a rare enteropathy characterized by villous atrophy and a thickened subepithelial collagen band. The aim of this study is to describe the cross-sectional imaging findings of CS. A case-control, retrospective study with cases of all CS patients from January 2000 to 2015 was performed. Inclusion criteria were (1) Histopathologic diagnosis and (2) Imaging with computed tomography abdomen/pelvis (CT A/P), CT enterography (CTE), or magnetic resonance enterography within 6 months of small bowel (SB) biopsy. Control subjects were irritable bowel syndrome (IBS) patients who underwent CTE. Imaging studies were examined by two GI radiologists, blinded to patient data. 108 patients (54 CS; 54 IBS) were included. Mean age was 56.7 ± 16.5 years, and 68% were female (72% in CS group vs. 63% in IBS group; p = 0.3). CS patients were significantly older (67 ± 12 vs. 47 ± 15 year; p reversal (46% vs. 6%; p < 0.001), SB dilation (28% vs. 0%; p < 0.001), SB conformational change (28% vs. 6%; p = 0.002), SB wall thickening (13% vs. 2%; p = 0.03), and ulcerative jejunoileitis (4% vs. 0%; p = 0.01). Radiologists suspected malabsorption in 72% in the CS group and 2% in the IBS group (p < 0.001). Imaging findings suggestive of mucosal malabsorption are commonly demonstrated in CS.

  11. Diffusion Tensor Imaging: Application to the Study of the Developing Brain

    Science.gov (United States)

    Cascio, Carissa J.; Gerig, Guido; Piven, Joseph

    2007-01-01

    Objective: To provide an overview of diffusion tensor imaging (DTI) and its application to the study of white matter in the developing brain in both healthy and clinical samples. Method: The development of DTI and its application to brain imaging of white matter tracts is discussed. Forty-eight studies using DTI to examine diffusion properties of…

  12. Syllabus for Privacy and Information Technology, Fall 2017, UCLA Information Studies

    OpenAIRE

    Borgman, Christine L.

    2017-01-01

    Privacy is a broad topic that covers many disciplines, stakeholders, and concerns. This course addresses the intersection of privacy and information technology, surveying a wide array of topics of concern for research and practice in the information fields. Among the topics covered are the history and changing contexts of privacy; privacy risks and harms; law, policies, and practices; privacy in searching for information, in reading, and in libraries; surveillance, networks, and privacy by de...

  13. Development of clinical study and application on dopaminergic neurotransmitters and neuroreceptor imaging

    International Nuclear Information System (INIS)

    Wang Rongfu

    2000-01-01

    In recent years, the neurotransmitter mapping has been rapidly developed from a lot of fundamental researches to the studies of clinical applications. At present, the dopaminergic neurotransmitter and receptor imaging in the central neurotransmitter mapping study are the most active area including dopaminergic receptor, dopaminergic neurotransmitter and dopaminergic transporter imaging, etc,. The nuclear medicine functional imaging technique with positron emission tomography and single photon emission computed tomography possesses potential advantages in the diagnosis and distinguished diagnosis of neuropsychiatric disorders and movement disorders, and in the study of recognition function

  14. New Image Qualities in Education: A Comparative Study

    Science.gov (United States)

    Çankaya, Ibrahim

    2018-01-01

    The aim of this study is to compare Turkish and European Union Countries Educations in terms of the new image qualities such as data like access to online education, digital access, foreign languages learnt per pupil, research & development investments, human resources employed in science and technology, the study opportunities offered to…

  15. An Exploratory Study of Residents' Perception of Place Image: The Case of Kavala.

    Science.gov (United States)

    Stylidis, Dimitrios; Sit, Jason; Biran, Avital

    2016-05-01

    Studies on place image have predominantly focused on the tourists' destination image and have given limited attention to other stakeholders' perspectives. This study aims to address this gap by focusing on the notion of residents' place image, whereby it reviews existing literature on residents' place image in terms of whether common attributes can be identified, and examines the role of community-focused attributes in its measurement. Data collected from a sample of 481 Kavala residents (Greece) were subjected to exploratory and confirmatory factor analysis. The study reveals that the existing measurement tools have typically emphasized destination-focused attributes and neglected community-focused attributes. This study contributes to the residents' place image research by proposing a more holistic measurement, which consisted of four dimensions: physical appearance, community services, social environment, and entertainment opportunities. The study also offers practical insights for developing and promoting a tourist place while simultaneously enhancing its residents' quality of life.

  16. Comparison of implant-abutment interface misfits after casting and soldering procedures.

    Science.gov (United States)

    Neves, Flávio Domingues das; Elias, Gisele Araújo; da Silva-Neto, João Paulo; de Medeiros Dantas, Lucas Costa; da Mota, Adérito Soares; Neto, Alfredo Júlio Fernandes

    2014-04-01

    The aim of this study was to compare vertical and horizontal adjustments of castable abutments after conducting casting and soldering procedures. Twelve external hexagonal implants (3.75 × 10 mm) and their UCLA abutments were divided according their manufacturer and abutment type: PUN (plastic UCLA, Neodent), PUC (plastic UCLA, Conexão), PU3i (plastic UCLA, Biomet 3i), and PUTN (plastic UCLA with Tilite milled base, Neodent). Three infrastructures of a fixed partial implant-supported bridge with 3 elements were produced for each group. The measurements of vertical (VM) and horizontal (HM) misfits were obtained via scanning electron microscopy after completion of casting and soldering. The corresponding values were determined to be biomechanically acceptable to the system, and the results were rated as a percentage. Statistical analysis establishes differences between groups by chi-square after procedures, and McNeman's test was applied to analyze the influence of soldering over casting (α ≤ .05). For the values of VM and HM, respectively, when the casting process was complete, it was observed that 83.25% and 100% (PUTN), 33.3% and 27.75% (PUN), 33.3% and 88.8% (PUC), 33.3% and 94.35% (PU3i) represented acceptable values. After completing the requisite soldering, acceptable values were 50% and 94.35% (PUTN), 16.6% and 77.7% (PUN), 38.55% and 77.7% (PUC), and 27.75% and 94.35% (PU3i). Within the limitations of this study, it can be concluded that the premachined abutments presented more acceptable VM values. The HM values were within acceptable limits before and after the soldering procedure for most groups. Further, the soldering procedure resulted in an increase of VM in all groups.

  17. A study on assessment of bone mass from aluminum-equivalent image by digital imaging system

    International Nuclear Information System (INIS)

    Kim, Jin Soo; Kim, Jae Duck; Choi, Eui Hwan

    1997-01-01

    The purpose of this study was to evaluated the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxy apatite block and hydroxyapatite mass. The results of this study were as follows : 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated (r2=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference (P<0.05) between them. 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r2 =0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different (P<0.05).

  18. Comparative study of digital laser film and analog paper image recordings

    International Nuclear Information System (INIS)

    Lee, K.R.; Cox, G.G.; Templeton, A.W.; Preston, D.F.; Anderson, W.H.; Hensley, K.S.; Dwyer, S.J.

    1987-01-01

    The increase in the use of various imaging modalities demands higher quality and more efficacious analog image recordings. Laser electronic recordings with digital array prints of 4,000 x 5,000 x 12 bits obtained using laser-sensitive film or paper are being evaluated. Dry silver paper recordings are being improved and evaluated. High-resolution paper dot printers are being studied to determine their gray-scale capabilities. The authors evaluated the image quality, costs, clinical utilization, and acceptability of CT scans, MR images, digital subtraction angiograms, digital radiographs, and radionuclide scans recorded by seven different printers (three laser, three silver paper, and one dot) and compared the same features in conventional film recording. This exhibit outlines the technical developments and instrumentation of digital laser film and analog paper recorders and presents the results of the study

  19. Small Animal [18F]FDG PET Imaging for Tumor Model Study

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Kyeong Min; Cheon, Gi Jeong

    2008-01-01

    PET allows non-invasive, quantitative and repetitive imaging of biological function in living animals. Small animal PET imaging with [ 18 F]FDG has been successfully applied to investigation of metabolism, receptor, ligand interactions, gene expression, adoptive cell therapy and somatic gene therapy. Experimental condition of animal handling impacts on the biodistribution of [ 18 F]FDG in small animal study. The small animal PET and CT images were registered using the hardware fiducial markers and small animal contour point. Tumor imaging in small animal with small animal [ 18 F]FDG PET should be considered fasting, warming, and isoflurane anesthesia level. Registered imaging with small animal PET and CT image could be useful for the detection of tumor. Small animal experimental condition of animal handling and registration method will be of most importance for small lesion detection of metastases tumor model

  20. Accuracy and reproducibility of tumor positioning during prolonged and multi-modality animal imaging studies

    International Nuclear Information System (INIS)

    Zhang Mutian; Huang Minming; Le, Carl; Zanzonico, Pat B; Ling, C Clifton; Koutcher, Jason A; Humm, John L; Claus, Filip; Kolbert, Katherine S; Martin, Kyle

    2008-01-01

    Dedicated small-animal imaging devices, e.g. positron emission tomography (PET), computed tomography (CT) and magnetic resonance imaging (MRI) scanners, are being increasingly used for translational molecular imaging studies. The objective of this work was to determine the positional accuracy and precision with which tumors in situ can be reliably and reproducibly imaged on dedicated small-animal imaging equipment. We designed, fabricated and tested a custom rodent cradle with a stereotactic template to facilitate registration among image sets. To quantify tumor motion during our small-animal imaging protocols, 'gold standard' multi-modality point markers were inserted into tumor masses on the hind limbs of rats. Three types of imaging examination were then performed with the animals continuously anesthetized and immobilized: (i) consecutive microPET and MR images of tumor xenografts in which the animals remained in the same scanner for 2 h duration, (ii) multi-modality imaging studies in which the animals were transported between distant imaging devices and (iii) serial microPET scans in which the animals were repositioned in the same scanner for subsequent images. Our results showed that the animal tumor moved by less than 0.2-0.3 mm over a continuous 2 h microPET or MR imaging session. The process of transporting the animal between instruments introduced additional errors of ∼0.2 mm. In serial animal imaging studies, the positioning reproducibility within ∼0.8 mm could be obtained.

  1. The creation of inter-ethnic images for studies in applied psychology.

    Science.gov (United States)

    Vanezis, Maria; Vanezis, Peter; Minnis, Helen; McMillan, Alison; Gillies, Marjorie; Smith, Shubulade

    2003-10-01

    The facial transformation programme, is an integral part of the computerised three-dimensional facial reconstruction system, employed at the University of Glasgow for forensic and historical cases. It was applied to the creation of inter-ethnic images for use in studies to assess the response of various groups to facial appearance in the assessment of racial stereotyping. We initially acquired a three-dimensional facial image from a young black (Negroid) male volunteer, using our optical laser scanning system. This image was then used as a template over a Caucasian skull to produce a reconstruction using facial criteria applicable to white (Caucasian) males. The other image used was that of the facial template of the black male. A commercially available electronic identikit system, E-FIT was then used to add appropriate hair styles and open eyes to both images. In addition, on the 'Caucasian reconstruction' we were able to reduce the contrast and lighting on the face. This was relatively straightforward as we were using greyscale images rather than colour. The shape of the nose and lips on the white male were also altered to be more in keeping with Caucasoid average measurements. The resulting images were shown to a group of second-year clinical psychology students and their responses are discussed. Similar images may also be used in studies of racial stereotyping in different categories of professionals such as police, prison personnel, probation officers, social workers, potential employers, doctors, and others, in order to assess the response to individuals by facial appearance.

  2. The study of surgical image quality evaluation system by subjective quality factor method

    Science.gov (United States)

    Zhang, Jian J.; Xuan, Jason R.; Yang, Xirong; Yu, Honggang; Koullick, Edouard

    2016-03-01

    GreenLightTM procedure is an effective and economical way of treatment of benign prostate hyperplasia (BPH); there are almost a million of patients treated with GreenLightTM worldwide. During the surgical procedure, the surgeon or physician will rely on the monitoring video system to survey and confirm the surgical progress. There are a few obstructions that could greatly affect the image quality of the monitoring video, like laser glare by the tissue and body fluid, air bubbles and debris generated by tissue evaporation, and bleeding, just to name a few. In order to improve the physician's visual experience of a laser surgical procedure, the system performance parameter related to image quality needs to be well defined. However, since image quality is the integrated set of perceptions of the overall degree of excellence of an image, or in other words, image quality is the perceptually weighted combination of significant attributes (contrast, graininess …) of an image when considered in its marketplace or application, there is no standard definition on overall image or video quality especially for the no-reference case (without a standard chart as reference). In this study, Subjective Quality Factor (SQF) and acutance are used for no-reference image quality evaluation. Basic image quality parameters, like sharpness, color accuracy, size of obstruction and transmission of obstruction, are used as subparameter to define the rating scale for image quality evaluation or comparison. Sample image groups were evaluated by human observers according to the rating scale. Surveys of physician groups were also conducted with lab generated sample videos. The study shows that human subjective perception is a trustworthy way of image quality evaluation. More systematic investigation on the relationship between video quality and image quality of each frame will be conducted as a future study.

  3. Comparison of image quality in head CT studies with different dose-reduction strategies

    DEFF Research Database (Denmark)

    Johansen, Jeppe; Nielsen, Rikke; Fink-Jensen, Vibeke

    The number of multi-detector CT examinations is increasing rapidly. They allow high quality reformatted images providing accurate and precise diagnosis at maximum speed. Brain examinations are the most commonly requested studies, and although they come at a lower effective dose than body CT, can...... account to a considerable radiation dose as many patients undergo repeated studies. Therefore, various dose-reduction strategies are applied such as automated tube current and voltage modulation and recently different iterative reconstruction algorithms. However, the trade-off of all dose......-reduction maneuvers is reduction of image quality due to image noise or artifacts. The aim of our study was therefore to find the best diagnostic images with lowest possible dose. We present results of dose- and image quality optimizing strategies of brain CT examinations at our institution. We compare sequential...

  4. A Multimodal Search Engine for Medical Imaging Studies.

    Science.gov (United States)

    Pinho, Eduardo; Godinho, Tiago; Valente, Frederico; Costa, Carlos

    2017-02-01

    The use of digital medical imaging systems in healthcare institutions has increased significantly, and the large amounts of data in these systems have led to the conception of powerful support tools: recent studies on content-based image retrieval (CBIR) and multimodal information retrieval in the field hold great potential in decision support, as well as for addressing multiple challenges in healthcare systems, such as computer-aided diagnosis (CAD). However, the subject is still under heavy research, and very few solutions have become part of Picture Archiving and Communication Systems (PACS) in hospitals and clinics. This paper proposes an extensible platform for multimodal medical image retrieval, integrated in an open-source PACS software with profile-based CBIR capabilities. In this article, we detail a technical approach to the problem by describing its main architecture and each sub-component, as well as the available web interfaces and the multimodal query techniques applied. Finally, we assess our implementation of the engine with computational performance benchmarks.

  5. A Study of Color Transformation on Website Images for the Color Blind

    OpenAIRE

    Siew-Li Ching; Maziani Sabudin

    2010-01-01

    In this paper, we study on color transformation method on website images for the color blind. The most common category of color blindness is red-green color blindness which is viewed as beige color. By transforming the colors of the images, the color blind can improve their color visibility. They can have a better view when browsing through the websites. To transform colors on the website images, we study on two algorithms which are the conversion techniques from RGB colo...

  6. Direct Imaging of Stellar Surfaces: Results from the Stellar Imager (SI) Vision Mission Study

    Science.gov (United States)

    Carpenter, Kenneth; Schrijver, Carolus; Karovska, Margarita

    2006-01-01

    The Stellar Imager (SI) is a UV-Optical, Space-Based Interferometer designed to enable 0.1 milli-arcsecond (mas) spectral imaging of stellar surfaces and stellar interiors (via asteroseismology) and of the Universe in general. SI is identified as a "Flagship and Landmark Discovery Mission'' in the 2005 Sun Solar System Connection (SSSC) Roadmap and as a candidate for a "Pathways to Life Observatory'' in the Exploration of the Universe Division (EUD) Roadmap (May, 2005). The ultra-sharp images of the Stellar Imager will revolutionize our view of many dynamic astrophysical processes: The 0.1 mas resolution of this deep-space telescope will transform point sources into extended sources, and snapshots into evolving views. SI's science focuses on the role of magnetism in the Universe, particularly on magnetic activity on the surfaces of stars like the Sun. SI's prime goal is to enable long-term forecasting of solar activity and the space weather that it drives in support of the Living With a Star program in the Exploration Era. SI will also revolutionize our understanding of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes in the Universe. In this paper we will discuss the results of the SI Vision Mission Study, elaborating on the science goals of the SI Mission and a mission architecture that could meet those goals.

  7. Red fluorescence imaging for dental plaque detection and quantification: pilot study

    Science.gov (United States)

    Liu, Zhao; Gomez, Juliana; Khan, Soniya; Peru, Debbie; Ellwood, Roger

    2017-09-01

    The red fluorescence of dental plaque originating from porphyrins in oral bacteria may allow visualization, detection, and scoring of plaque without disclosing agents. Two studies were conducted. The first included 24 healthy participants who abstained from oral hygiene for 24 h. Dental plaque was collected from tooth surfaces, and a 10% solution was prepared. These were scanned by a molecular spectrometer to identify the optimum excitation and emission wavelengths of plaque for developing a red fluorescence imaging system. Fourteen healthy subjects completed the second study. After a washout period (1 week), participants had a prophylaxis at baseline and abstained from oral hygiene during the study. They were monitored using the fluorescence imaging system at baseline, 24 h, and 48 h. A dentist clinically assessed plaque after disclosing and on red fluorescence images. Three descriptors were extracted from images and a RUSBoost classifier derived computer fluorescence scores through cross-validation. Red fluorescence plaque levels increased during the 48-h accumulation. Plaque progression was identified by dentist assessment and computer analysis, presenting significant differences between visits at tooth and subject levels (phygiene assessment.

  8. Feasibility study of superharmonic imaging using chirps

    NARCIS (Netherlands)

    Van Neer, P.; Danilouchkine, M.G.; Matte, G.; Voormolen, M.M.; Verweij, M.D.; De Jong, N.

    2010-01-01

    Superharmonic imaging (SHI) targets a combination of the 3rd to 5th harmonics. It was proven to have certain advantages in comparison with the established imaging standards in medical utrasound. SHI enhances the spatial resolution and improves the quality of echographic images, mainly by eliminating

  9. Optimization for PET imaging based on phantom study and NECdensity

    International Nuclear Information System (INIS)

    Daisaki, Hiromitsu; Shimada, Naoki; Shinohara, Hiroyuki

    2012-01-01

    In consideration of the requirement for global standardization and quality control of PET imaging, the present studies gave an outline of phantom study to decide both scan and reconstruction parameters based on FDG-PET/CT procedure guideline in Japan, and optimization of scan duration based on NEC density was performed continuously. In the phantom study, scan and reconstruction parameters were decided by visual assessment and physical indexes (N 10mm , NEC phantom , Q H,10mm /N 10mm ) to visualize hot spot of 10 mm diameter with standardized uptake value (SUV)=4 explicitly. Simultaneously, Recovery Coefficient (RC) was evaluated to recognize that PET images had enough quantifiably. Scan durations were optimized by Body Mass Index (BMI) based on retrospective analysis of NEC density . Correlation between visual score in clinical FDG-PET images and NEC density fell after the optimization of scan duration. Both Inter-institution and inter-patient variability were decreased by performing the phantom study based on the procedure guideline and the optimization of scan duration based on NEC density which seem finally useful to practice highly precise examination and promote high-quality controlled study. (author)

  10. Correlation of early-phase {sup 18}F-florbetapir (AV-45/Amyvid) PET images to FDG images: preliminary studies

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao, Ing-Tsung; Hsieh, Chia-Ju; Wey, Shiaw-Pyng; Lin, Kun-Ju [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); Huang, Chin-Chang; Hsu, Wen-Chun [Chang Gung Memorial Hospital, Department of Neurology, Taipei (China); Yen, Tzu-Chen [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Kung, Mei-Ping [Chang Gung Memorial Hospital, Department of Nuclear Medicine and Molecular Imaging Center, Taipei (China); Chang Gung University, Healthy Aging Research Center and Department of Medical Imaging and Radiological Sciences, Taipei (China); University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States)

    2012-04-15

    {sup 18}F-Florbetapir (AV-45/Amyvid) is a novel positron emission tomography (PET) tracer for imaging plaque pathology in Alzheimer's disease (AD), while PET images of fluorodeoxyglucose (FDG) for cerebral glucose metabolism can provide complementary information to amyloid plaque images for diagnosis of AD. The goal of this preliminary study was to investigate the perfusion-like property of relative cerebral blood flow estimates (R{sub 1}) and summed early-phase AV-45 images [perfusion AV-45 (pAV-45)] and optimize the early time frame for pAV-45. Dynamic AV-45 PET scans (0-180 min) were performed in seven subjects. pAV-45, late-phase AV-45, and FDG images were spatially normalized to the Montreal Neurological Institute template aided by individual MRI images, and the corresponding standardized uptake value ratio (SUVR) was computed. The R{sub 1} images were derived from a simplified reference tissue model. Correlations between regional and voxelwise R{sub 1} and the corresponding FDG images were calculated. An optimization of time frames of pAV-45 was conducted in terms of correlation to FDG images. The optimal early time frame was validated in a separate cohort. The regional distribution in the R{sub 1} images correlated well (R = 0.91) to that of the FDG within subjects. Consistently high correlation was noted across a long range of time frames. The maximal correlation of pAV-45 to FDG SUVR of R = 0.95 was observed at the time frame of 1-6 min, while the peak correlation of R = 0.99 happened at 0-2 min between pAV-45 and R{sub 1}. A similar result was achieved in the validation cohort. Preliminary results showed that the distribution patterns of R{sub 1} and pAV-45 images are highly correlated with normalized FDG images, and the initial 5-min early time frame of 1-6 min is potentially useful in providing complementary FDG-like information to the amyloid plaque density by late-phase AV-45 images. (orig.)

  11. In vivo study of experimental pneumococcal meningitis using magnetic resonance imaging

    DEFF Research Database (Denmark)

    Brandt, C.T.; Simonsen, H.; Liptrot, Matthew George

    2008-01-01

    Background: Magnetic Resonance Imaging (MRI) methods were evaluated as a tool for the study of experimental meningitis. The identification and characterisation of pathophysiological parameters that vary during the course of the disease could be used as markers for future studies of new treatment...... strategies. Methods: Rats infected intracisternally with S. pneumoniae (n = 29) or saline (n = 13) were randomized for imaging at 6, 12, 24, 30, 36, 42 or 48 hours after infection. T1W, T2W, quantitative diffusion, and post contrast T1W images were acquired at 4.7 T. Dynamic MRI (dMRI) was used to evaluate...... blood-brain-barrier (BBB) permeability and to obtain a measure of cerebral and muscle perfusion. Clinical- and motor scores, bacterial counts in CSF and blood, and WBC counts in CSF were measured. Results: MR images and dMRI revealed the development of a highly significant increase in BBB permeability...

  12. Progress of study on the dopamine D4 receptor imaging agent

    International Nuclear Information System (INIS)

    Tian Haibin; Zhang Lan; Zhang Chunfu; Li Junling; Yin Duanzhi

    2001-01-01

    Dopamine receptors were originally classified into five receptors subtypes, the dopamine D 4 receptor was included. Schizophrenic pathophysiology may be associated with expression and function of the dopamine D 4 receptor; it is of great importance to study the imaging agent of dopamine D 4 receptor. The study on radioactivity distribution and metabolize of radioligand remains hampered by the lack radioligand for the D 4 receptor which can be labeled using suitable nuclei. This paper reviews the progress of study on the dopamine D 4 receptor imaging agent, with particular emphasis vary nuclei, for example 11 C, 18 F, 123 I, labeled D 4 receptor ligands, antagonists and analogs as PET or SPECT imaging agents. Authors estimated affinity and selectivity of radioligands for the dopamine D 4 receptor in laboratory animal tests

  13. Preliminary study of synthetic aperture tissue harmonic imaging on in-vivo data

    DEFF Research Database (Denmark)

    Rasmussen, Joachim Hee; Hemmsen, Martin Christian; Sloth Madsen, Signe

    2013-01-01

    . Results from the image quality study show, that in the current configuration on the UltraView system, where no transmit apodization was applied, SASB-THI and DRF-THI produced equally good images. It is expected that given the use of transmit apodization, SASB-THI could be further improved.......A method for synthetic aperture tissue harmonic imaging is investigated. It combines synthetic aperture sequential beamforming (SASB) with tissue harmonic imaging (THI) to produce an increased and more uniform spatial resolution and improved side lobe reduction compared to conventional B......-mode imaging. Synthetic aperture sequential beamforming tissue harmonic imaging (SASB-THI) was implemented on a commercially available BK 2202 Pro Focus UltraView ultrasound system and compared to dynamic receive focused tissue harmonic imaging (DRF-THI) in clinical scans. The scan sequence...

  14. Comparative study on the performance of textural image features for active contour segmentation.

    Science.gov (United States)

    Moraru, Luminita; Moldovanu, Simona

    2012-07-01

    We present a computerized method for the semi-automatic detection of contours in ultrasound images. The novelty of our study is the introduction of a fast and efficient image function relating to parametric active contour models. This new function is a combination of the gray-level information and first-order statistical features, called standard deviation parameters. In a comprehensive study, the developed algorithm and the efficiency of segmentation were first tested for synthetic images. Tests were also performed on breast and liver ultrasound images. The proposed method was compared with the watershed approach to show its efficiency. The performance of the segmentation was estimated using the area error rate. Using the standard deviation textural feature and a 5×5 kernel, our curve evolution was able to produce results close to the minimal area error rate (namely 8.88% for breast images and 10.82% for liver images). The image resolution was evaluated using the contrast-to-gradient method. The experiments showed promising segmentation results.

  15. Body image and gestational weight gain: a prospective study.

    Science.gov (United States)

    Hill, Briony; Skouteris, Helen; McCabe, Marita; Fuller-Tyszkiewicz, Matthew

    2013-01-01

    Approximately 50% of Australian adult women of childbearing age are overweight or obese, and, when pregnant, the majority gain excessive weight; this is also the case in the United States and other developed nations. High gestational weight gain (GWG) is the strongest predictor of maternal overweight/obesity postbirth and is also associated with an increased risk of childhood obesity. Understanding factors that contribute to excessive GWG is vital in combating obesity. The aim of the current study was to examine whether body image attitudes (eg, feeling fat, attractive, or strong and fit, and salience of weight and shape) predict GWG. Pregnant women, recruited through advertisements on pregnancy online forums and parenting magazines, completed questionnaires assessing body image, demographic variables, and GWG. The Body Attitudes Questionnaire assessed body image in early-to-middle, middle, and late pregnancy (mean of 16.8, 24.7, and 33.0 weeks' gestation, respectively). Total GWG was calculated by subtracting self-reported pre pregnancy weight from self-reported weight at 36.8 weeks' gestation. A total of 150 pregnant women responded to the study's advertisements, and 72% (n = 108) took part. After controlling for pre pregnancy body mass index (BMI), lower attractiveness in early-to-middle pregnancy was associated with higher GWG. In late pregnancy, women who had the lowest feelings of fatness had greater GWG. Body image attitudes earlier in pregnancy did not predict whether GWG recommendations were exceeded. Women of higher BMI were more likely to gain excessive weight. The findings suggest that the type and timing of pregnancy, body attitudes, and the time of pregnancy when they are noted, predict GWG. However, more research in the area is needed, including assessment of the relationship between body image concerns, GWG, and other psychosocial factors. We recommend that midwives monitor body image concerns in pregnancy to help address factors affecting GWG in at

  16. A comparative study on medical image segmentation methods

    Directory of Open Access Journals (Sweden)

    Praylin Selva Blessy SELVARAJ ASSLEY

    2014-03-01

    Full Text Available Image segmentation plays an important role in medical images. It has been a relevant research area in computer vision and image analysis. Many segmentation algorithms have been proposed for medical images. This paper makes a review on segmentation methods for medical images. In this survey, segmentation methods are divided into five categories: region based, boundary based, model based, hybrid based and atlas based. The five different categories with their principle ideas, advantages and disadvantages in segmenting different medical images are discussed.

  17. The experimental study of oxygen contrast MR ventilation imaging

    International Nuclear Information System (INIS)

    Yang Jian; Guo Youmin; Wu Xiaoming; Xi Nong; Wang Jianguo; Zhu Li; Lei Xiaoyan; Xie Enyi

    2003-01-01

    Objective: To study the feasibility and basic technology of the oxygen contrast MR ventilation imaging in lung. Methods: Six canine lungs were scanned by using inversion recovery pulse sequence with turbo spin echo acquisition before and after inhalation of the 100% oxygen as T 1 contrast agent, and the T 1 values were measured. The contrast-to-noise ratio (CNR) for each inversion recovery time was compared and the relationship between arterial blood oxygen pressure (PaO 2 ) and T 1 relaxation rate was observed. Subtraction technique was employed in the postprocessing of pre- and post-oxygen conditions. Results: Molecular oxygen could shorten the pulmonary T 1 value (average 13.37%, t=2.683, P 1 value of pre- and post-oxygen conditions. The relaxtivity of T 1 resulted in excellent linear correlation (r 2 =0.9974) with PaO 2 . Through the subtraction of pre- and post-oxygen image, the oxygen contrast MR ventilation -image was obtained. Conclusion: The oxygen contrast MR ventilation imaging has the feasibility and clinical potential for the assessment of regional pulmonary function

  18. Preliminary study of synthetic aperture tissue harmonic imaging on in-vivo data

    Science.gov (United States)

    Rasmussen, Joachim H.; Hemmsen, Martin C.; Madsen, Signe S.; Hansen, Peter M.; Nielsen, Michael B.; Jensen, Jørgen A.

    2013-03-01

    A method for synthetic aperture tissue harmonic imaging is investigated. It combines synthetic aperture sequen- tial beamforming (SASB) with tissue harmonic imaging (THI) to produce an increased and more uniform spatial resolution and improved side lobe reduction compared to conventional B-mode imaging. Synthetic aperture sequential beamforming tissue harmonic imaging (SASB-THI) was implemented on a commercially available BK 2202 Pro Focus UltraView ultrasound system and compared to dynamic receive focused tissue harmonic imag- ing (DRF-THI) in clinical scans. The scan sequence that was implemented on the UltraView system acquires both SASB-THI and DRF-THI simultaneously. Twenty-four simultaneously acquired video sequences of in-vivo abdominal SASB-THI and DRF-THI scans on 3 volunteers of 4 different sections of liver and kidney tissues were created. Videos of the in-vivo scans were presented in double blinded studies to two radiologists for image quality performance scoring. Limitations to the systems transmit stage prevented user defined transmit apodization to be applied. Field II simulations showed that side lobes in SASB could be improved by using Hanning transmit apodization. Results from the image quality study show, that in the current configuration on the UltraView system, where no transmit apodization was applied, SASB-THI and DRF-THI produced equally good images. It is expected that given the use of transmit apodization, SASB-THI could be further improved.

  19. Unexpected findings at imaging: Predicting frequency in various types of studies

    International Nuclear Information System (INIS)

    Lumbreras, Blanca; Gonzalez-Alvarez, Isabel; Lorente, Ma Fernanda; Calbo, Jorge; Aranaz, Jesus; Hernandez-Aguado, Ildefonso

    2010-01-01

    Objective: The objective was to evaluate the prevalence and associated variables of unsuspected findings from imaging tests in clinical practice. Material and Methods: Cross-sectional study of patients referred for an imaging test in 2006. Two independent radiologists classified the imaging tests according to the presence or absence of an unexpected finding in relation with the causes that prompted the test (kappa = 0.95). A thorough chart review of these patients was carried out as a quality control. Results: Out of 3259 patients in the study, 488 revealed unsuspected findings (15.0%). The prevalence of abnormal findings varied according to age: from 20.4% (150/734) in the over 74-group to 9.0% (76/847) in the under 43-group. The largest prevalence was in the category of infectious diseases (14/49, 28.6%) and in CT (260/901, 28.9%) and ultrasound (138/668, 20.7%). Studies showing moderate clinical information on the referral form were less likely to show unexpected findings than those with null or minor information (OR 0.51; 95% CI 0.36-0.73). Conclusion: Clinicians should expect the frequency of diseases detectable by imaging to increase in the future. Further research with follow-up of these findings is needed to estimate the effect of imaging technologies on final health outcomes.

  20. Unexpected findings at imaging: Predicting frequency in various types of studies

    Energy Technology Data Exchange (ETDEWEB)

    Lumbreras, Blanca [Public Health Department, Miguel Hernandez University (Spain); CIBER en Epidemiologia y Salud Publica (Spain)], E-mail: blumbreras@umh.es; Gonzalez-Alvarez, Isabel [Radiodiagnostic Department, San Juan Hospital, 03550 Alicante (Spain)], E-mail: gonzalez_isa@gva.es; Lorente, Ma Fernanda [Radiodiagnostic Department, San Juan Hospital, 03550 Alicante (Spain)], E-mail: MARFERLORENTE@telefonica.net; Calbo, Jorge [Radiodiagnostic Department, San Juan Hospital, 03550 Alicante (Spain)], E-mail: jocalma@hotmail.com; Aranaz, Jesus [Preventive Medicine Department, San Juan Hospital, 03550 Alicante (Spain)], E-mail: aranaz_jes@gva.es; Hernandez-Aguado, Ildefonso [Public Health Department, Miguel Hernandez University (Spain); CIBER en Epidemiologia y Salud Publica (Spain)], E-mail: ihernandez@umh.es

    2010-04-15

    Objective: The objective was to evaluate the prevalence and associated variables of unsuspected findings from imaging tests in clinical practice. Material and Methods: Cross-sectional study of patients referred for an imaging test in 2006. Two independent radiologists classified the imaging tests according to the presence or absence of an unexpected finding in relation with the causes that prompted the test (kappa = 0.95). A thorough chart review of these patients was carried out as a quality control. Results: Out of 3259 patients in the study, 488 revealed unsuspected findings (15.0%). The prevalence of abnormal findings varied according to age: from 20.4% (150/734) in the over 74-group to 9.0% (76/847) in the under 43-group. The largest prevalence was in the category of infectious diseases (14/49, 28.6%) and in CT (260/901, 28.9%) and ultrasound (138/668, 20.7%). Studies showing moderate clinical information on the referral form were less likely to show unexpected findings than those with null or minor information (OR 0.51; 95% CI 0.36-0.73). Conclusion: Clinicians should expect the frequency of diseases detectable by imaging to increase in the future. Further research with follow-up of these findings is needed to estimate the effect of imaging technologies on final health outcomes.

  1. Techniques necessary for multiple tracer quantitative small-animal imaging studies

    International Nuclear Information System (INIS)

    Sharp, Terry L.; Dence, Carmen S.; Engelbach, John A.; Herrero, Pilar; Gropler, Robert J.; Welch, Michael J.

    2005-01-01

    Introduction: An increasing number and variety of studies on rodent models are being conducted using small-animal positron emission tomography scanners. We aimed to determine if animal handling techniques could be developed to perform routine animal imaging in a timely and efficient manner and with minimal effect on animal physiology. These techniques need to be reproducible in the same animal while maintaining hemodynamic and physiological stability. Methods: The necessary techniques include (a) the use of inhalant anesthesia, (b) arterial and venous cannulation for multiple tracer administrations and blood sampling, (c) development of small-volume analytic columns and techniques and (d) measurement of the physiological environment during the imaging session. Results: We provide an example of a cardiac imaging study using four radiotracers ( 15 O-water, 1-[ 11 C]-acetate, 1-[ 11 C]-palmitate and 1-[ 11 C]-glucose) injected into normal rats. Plasma substrates, CO 2 production and total metabolites were measured. The animals remained anesthetized over the entire imaging session, and their physiological state was maintained. Conclusion: The intrastudy stability of the physiological measurements and substrate levels and interstudy reproducibility of the measurements are reported

  2. Preliminary study on X-ray phase contrast imaging using synchrotron radiation facility

    International Nuclear Information System (INIS)

    Xiong Zhuang; Wang Jianhua; Yu Yongqiang; Jiang Shiping; Chen Yang; Tian Yulian

    2006-01-01

    Objective: To study the methodology of X-ray phase contrast imaging using synchrotron radiation, and evaluate the quality of phase contrast images. Methods: Several experiments to obtain phase contrast images and absorption contrast images of various biological samples were conducted in Beijing Synchrotron Radiation Facility (BSRF), and then these images were interpreted to find out the difference between the two kinds of imaging methods. Results: Satisfactory phase contrast images of these various samples were obtained, and the quality of these images was superior to that obtained with absorption contrast imaging. The phase contrast formation is based on the phenomenon of fresnel diffraction which transforms phase shifts into intensity variations upon a simple act of free-space propagation, so it requires highly coherent X-rays and appropriate distance between sample and detector. This method of imaging is very useful in imaging of low-absorption objects or objects with little absorption variation, and its resolution is far higher than that of the conventional X-ray imaging. The photographs obtained showed very fine inner microstructure of the biological samples, and the smallest microstructure to be distinguished is within 30-40 μm. There is no doubt that phase contrast imaging has a practical applicability in medicine. Moreover, it improves greatly the efficiency and the resolution of the existing X-ray diagnostic techniques. Conclusions: X-ray phase contrast imaging can be performed with synchrotron radiation source and has some advantages over the conventional absorption contrast imaging. (authors)

  3. California: A Case Study in the Loss of Affirmative Action. A Policy Report

    Science.gov (United States)

    Gandara, Patricia

    2012-01-01

    This paper briefly reviews the various efforts undertaken by the University of California to maintain diversity in the institution, and especially at its highly competitive flagship campuses, UCLA and Berkeley, in the face of the loss of affirmative action during the mid-1990s. It demonstrates the continuing decline in representation of…

  4. Mapping of the image quality in myocardial scintigraphy: A national study

    International Nuclear Information System (INIS)

    Ohlson, Maria; Gustafsson, Agnetha; Gretarsdottir, Jakobina; Olsson, Eva; Johansson, Lena

    2008-04-01

    The aim of this study was to make a survey over the physical parameters and how they affect the image quality and the final diagnosis for myocardial perfusion SPECT in Sweden. Another aim was to evaluate the need for standardized acquisition and processing protocols for myocardial perfusion SPECT. All thirty nuclear medicine departments in Sweden that perform myocardial perfusion SPECT participated in the study. A thorax heart phantom was used to simulate two patients. All studies were acquired and processed with the parameters used clinically in each hospital respectively. A quantitative and a qualitative evaluation were performed. At each hospital, the local nuclear medicine physician interpreted the images as if they were true patient images. There are great differences in the acquiring and processing parameters used in myocardial perfusion SPECT studies in Sweden. The image quality varies greatly for the different hospital but was approved for the majority of the hospitals. Images from two hospitals were considered to be too poor to be diagnosed. The interpretations of the local nuclear medicine physicians differ but the majority has reported an adequate diagnosis. One third of the hospitals have reported false positive defects. All steps in the chain from the acquisition to the evaluation of the medicine physician must be performed with high quality. The determinative factors are the noise reduction filter, the orientation of the slices in the heart and the judgement of the local medicine physician. The acquiring and processing parameters proposed by EANM should be used. The hospitals are also recommended to investigate in the time and resources available, in order to educate all staff involved in the evaluation of myocardial studies

  5. Experimental imaging study of 99Tcm-ciprofloxacin in detection of infection

    International Nuclear Information System (INIS)

    He Wei; Chen Shaoliang; Mao Jinlei; Jiang Maosong

    2008-01-01

    Objective: Most of the current imaging agents fox inflammatory and(or) infectious dis- eases are not specific enough. It was studied that using ciprofloxacin(an antibiotics)labeled with 99 Tc m for a novel imaging agent detected inflammatory and(or) infectious foci in vivo. Methods: In this investigation, the biological properties were evaluated by pharmacologic experiments. The end points of this study were two. One was to study the biodistribution of 99 Tc m labeled ciprofloxacin (an antibiotics)in vivo. The other was to understand the potential role of 99 Tc m -ciprofloxacin in detecting inflammatory and(or) infectious foci in rabbit models. The biodistribution of 99 Tc m -ciprofloxacin was studied in mice models. Scintigraphy of 99 Tc m -ciprofloxacin was performed in rabbit models. Results: The labeling rate was over 90%. The dissociation of 99 Tc m ciprofloxacin was minimal within 8 h at room temperature. After intravenous injection, rapid plasma clearance and renal clearance were observed. Kidney, liver and spleen were the target organs for the accumulation of injected 99 Tc m -ciprofloxacin. In the infectious rabbit models (n=3), accumulation of 99 Tc m -ciprofloxacin was found at the infective lesion (left thigh). The dynamic study showed that the optimal acquisition time for 99 Tc m ciprofloxacin imaging was at 3 h after injection. Moreover, images could still be positive at 24 h after injection. Notably, little 99 Tc m -ciprofloxacin accumulation was observed at the inflammation foci in above rabbit models. Conclusion: 99 Tc m -ciprofloxacin could be a potential imaging agent for infectious rather than inflammatory disease in vivo in the future. (authors)

  6. A broad band X-ray imaging spectrophotometer for astrophysical studies

    Science.gov (United States)

    Lum, Kenneth S. K.; Lee, Dong Hwan; Ku, William H.-M.

    1988-01-01

    A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

  7. Importance of methodology on (99m)technetium dimercapto-succinic acid scintigraphic image quality: imaging pilot study for RIVUR (Randomized Intervention for Children With Vesicoureteral Reflux) multicenter investigation.

    Science.gov (United States)

    Ziessman, Harvey A; Majd, Massoud

    2009-07-01

    We reviewed our experience with (99m)technetium dimercapto-succinic acid scintigraphy obtained during an imaging pilot study for a multicenter investigation (Randomized Intervention for Children With Vesicoureteral Reflux) of the effectiveness of daily antimicrobial prophylaxis for preventing recurrent urinary tract infection and renal scarring. We analyzed imaging methodology and its relation to diagnostic image quality. (99m)Technetium dimercapto-succinic acid imaging guidelines were provided to participating sites. High-resolution planar imaging with parallel hole or pinhole collimation was required. Two core reviewers evaluated all submitted images. Analysis included appropriate views, presence or lack of patient motion, adequate magnification, sufficient counts and diagnostic image quality. Inter-reader agreement was evaluated. We evaluated 70, (99m)technetium dimercapto-succinic acid studies from 14 institutions. Variability was noted in methodology and image quality. Correlation (r value) between dose administered and patient age was 0.780. For parallel hole collimator imaging good correlation was noted between activity administered and counts (r = 0.800). For pinhole imaging the correlation was poor (r = 0.110). A total of 10 studies (17%) were rejected for quality issues of motion, kidney overlap, inadequate magnification, inadequate counts and poor quality images. The submitting institution was informed and provided with recommendations for improving quality, and resubmission of another study was required. Only 4 studies (6%) were judged differently by the 2 reviewers, and the differences were minor. Methodology and image quality for (99m)technetium dimercapto-succinic acid scintigraphy varied more than expected between institutions. The most common reason for poor image quality was inadequate count acquisition with insufficient attention to the tradeoff between administered dose, length of image acquisition, start time of imaging and resulting image

  8. Mammography imaging studies using a laue crystal analyzer

    International Nuclear Information System (INIS)

    Chapman, D.; Thomlinson, W.; Arfelli, F.

    1995-01-01

    Synchrotron based mammography imaging experiments have been performed with monochromatic x-rays in which a laue crystal placed after the object being imaged has been used to split the beam transmitted through the object. The X27C R ampersand D beamline at the National Synchrotron Light Source was used with the white beam monochromatized by a double crystal Si(111) monochromator tuned to 18 keV. The imaging beam was a thin horizontal line approximately 0.5 mm high by 100 mm wide. Images were acquired in line scan mode with the phantom and detector both scanned together. The detector for these experiments was an image plate. A thin Si(l11) laue analyzer was used to diffract a portion of the beam transmitted through the phantom before the image plate detector. This ''scatter free'' diffracted beam was then recorded on the image plate during the phantom scan. Since the thin laue crystal also transmitted a fraction of the incident beam, this beam was also simultaneously recorded on the image plate. The imaging results are interpreted in terms of an x-ray schliere or refractive index inhomogeneities. The analyzer images taken at various points in the rocking curve will be presented

  9. The brain imaging study of the organophosphorus pesticides poisoning

    International Nuclear Information System (INIS)

    Yang Yanmei; Liu Huaijun; Li Shuling; Wang Yongsheng; Huang Boyuan; Chi Cen; Shi Zhenyang; Cui Caixia; Zhou Lixia; Liu Runtian

    2004-01-01

    Objective: To summarize the CT and MR imaging findings in acute organophosphorus pesticides poisoning patients, and to improve the early diagnostic ability. Methods: The imaging of 34 patients of organophosphorus pesticides poisoning was analyzed, the poisons were all taken orally. The pesticides included methamidophos (12 cases), omethoate (15 cases), DDV (3 cases), and methylparathion (4 cases). According to the diagnosis and classification diagnosis criterion of acute organophosphorus pesticides poisoning, the patients were divided into two groups: mild or moderate grade group (24 cases) and severe grade group (10 cases). The relationship between the clinic grade and CT and MRI findings was studied. Results: in the severe grade group, 4 patients showed brain edema, presenting as sulcus and fissure flattened or disappeared, and ventricles and cisterns narrowed or closed 2-3 days after poisoning. In 3 patients 3 days to 3 months after poisoning, bilateral basal ganglion and cerebral cortex showed prolonged T 1 and T 2 signals, and high signal intensity was detected on FLAIR, and bilateral basal ganglion low density was revealed on CT. T 1 relaxation was shortened, T 2 WI and FLAIR imaging showed high signal intensity in 1 patient. The imaging of 1 patient 6 months after poisoning showed the cerebral sulcus, fissure and ventricle were enlarged. CT and MRI in the mild or moderate group were normal. By the Fisher's exact probabilities test, the imaging exhibition difference between the severe grade and mild or moderate grade patients was significant. Conclusion: The CT and MRI can reflect the brain injury after poisoning, and the imaging exhibitions were various. The imaging information can provide credible foundation for the therapy for lightening the brain edema and nourishing the brain cell

  10. Diagnostic imaging in the study of human hepatobiliary fascioliasis.

    Science.gov (United States)

    Cantisani, V; Cantisani, C; Mortelé, K; Pagliara, E; D'Onofrio, M; Fernandez, M; D'Ambrosio, U; Lombardi, V; Marigliano, C; Ricci, P

    2010-02-01

    Fascioliasis is a rare zoonotic disease caused by the trematode Fasciola hepatica. We present the typical patterns of hepatobiliary fascioliasis observed in ten patients studied with multimodality imaging. Between 2002 and 2005, ten women with fascioliasis were admitted to the Brigham and Women's Hospital, Harvard Medical School (BWH), with abdominal pain and mild fever. All imaging modalities, including ultrasound (US), computed tomography (CT), magnetic resonance (MR) imaging (n = 2) and endoscopic retrograde cholangiopancreatography (ERCP) (n = 1) were reviewed by two expert radiologists working in consensus. In all patients (10/10, 100%), US showed parenchymal heterogeneity characterised by multiple subcapsular and peribiliary hypoechoic nodular lesions that were ill-defined and coalesced into tubular or tortuous structures. In six patients (6/10, 60%), the lesions appeared hypoechoic, whereas in four patients (4/10, 40%), there was an alternation of hyperechoic and hypoechoic nodules. On CT, all patients (10/10, 100%) showed hypodense patchy lesions in subcapsular, peribiliary or periportal locations, which coalesced to form tubular structures and were more evident during the portal phase. Lesion diameter ranged from 2 cm to 7 cm. Capsular enhancement was seen in four cases on CT (4/10, 40%) and in one also at MR imaging. MR imaging, performed in two patients, confirmed the presence of the lesions, which appeared hyperintense on T2-weighted images and were characterised by mild peripheral enhancement after gadolinium administration. Four patients had gallbladder wall thickening (4/10, 40%), with parasites in the gallbladder lumen. Although rare, hepatobiliary fascioliasis should be considered in the differential diagnosis in the appropriate clinical scenario, especially in patients coming from endemic areas. The typical imaging pattern of fascioliasis is the presence of subcapsular, peribiliary or periportal nodules that are usually ill-defined and coalesce

  11. Pediatric Palliative Care: A Personal Story

    Medline Plus

    Full Text Available ... patient's and family's experience with illness. Category Science & Technology License Standard YouTube License Show more Show less ... 35 Teen Cancer Stories | UCLA Daltrey/Townshend Teen & Young Adult Cancer Program - Duration: 11:08. UCLA Health ...

  12. In-Flight Calibration Processes for the MMS Fluxgate Magnetometers

    Science.gov (United States)

    Bromund, K. R.; Leinweber, H. K.; Plaschke, F.; Strangeway, R. J.; Magnes, W.; Fischer, D.; Nakamura, R.; Anderson, B. J.; Russell, C. T.; Baumjohann, W.; hide

    2015-01-01

    The calibration effort for the Magnetospheric Multiscale Mission (MMS) Analog Fluxgate (AFG) and DigitalFluxgate (DFG) magnetometers is a coordinated effort between three primary institutions: University of California, LosAngeles (UCLA); Space Research Institute, Graz, Austria (IWF); and Goddard Space Flight Center (GSFC). Since thesuccessful deployment of all 8 magnetometers on 17 March 2015, the effort to confirm and update the groundcalibrations has been underway during the MMS commissioning phase. The in-flight calibration processes evaluatetwelve parameters that determine the alignment, orthogonalization, offsets, and gains for all 8 magnetometers usingalgorithms originally developed by UCLA and the Technical University of Braunschweig and tailored to MMS by IWF,UCLA, and GSFC. We focus on the processes run at GSFC to determine the eight parameters associated with spin tonesand harmonics. We will also discuss the processing flow and interchange of parameters between GSFC, IWF, and UCLA.IWF determines the low range spin axis offsets using the Electron Drift Instrument (EDI). UCLA determines the absolutegains and sensor azimuth orientation using Earth field comparisons. We evaluate the performance achieved for MMS andgive examples of the quality of the resulting calibrations.

  13. In-Flight Calibration Processes for the MMS Fluxgate Magnetometers

    Science.gov (United States)

    Bromund, K. R.; Leinweber, H. K.; Plaschke, F.; Strangeway, R. J.; Magnes, W.; Fischer, D.; Nakamura, R.; Anderson, B. J.; Russell, C. T.; Baumjohann, W.; Chutter, M.; Torbert, R. B.; Le, G.; Slavin, J. A.; Kepko, L.

    2015-12-01

    The calibration effort for the Magnetospheric Multiscale Mission (MMS) Analog Fluxgate (AFG) and Digital Fluxgate (DFG) magnetometers is a coordinated effort between three primary institutions: University of California, Los Angeles (UCLA); Space Research Institute, Graz, Austria (IWF); and Goddard Space Flight Center (GSFC). Since the successful deployment of all 8 magnetometers on 17 March 2015, the effort to confirm and update the ground calibrations has been underway during the MMS commissioning phase. The in-flight calibration processes evaluate twelve parameters that determine the alignment, orthogonalization, offsets, and gains for all 8 magnetometers using algorithms originally developed by UCLA and the Technical University of Braunschweig and tailored to MMS by IWF, UCLA, and GSFC. We focus on the processes run at GSFC to determine the eight parameters associated with spin tones and harmonics. We will also discuss the processing flow and interchange of parameters between GSFC, IWF, and UCLA. IWF determines the low range spin axis offsets using the Electron Drift Instrument (EDI). UCLA determines the absolute gains and sensor azimuth orientation using Earth field comparisons. We evaluate the performance achieved for MMS and give examples of the quality of the resulting calibrations.

  14. Body image in gay and straight men: a qualitative study.

    Science.gov (United States)

    Morgan, John F; Arcelus, Jon

    2009-11-01

    Recent research has emphasized vulnerability to eating disorders in gay men, with calls for research on causality, cultural factors and focus on a younger age cohort. This study aimed to examine body image and related eating behaviours in younger gay and straight men. Qualitative study using a sample of gay and straight male university students, applying audiotaped and transcribed depth interview subjected to interpretative phenomenological analysis. Fifteen young men (18-24) with a spectrum of sexual orientation (gay, straight and bisexual) agreed to participate. Five dominant categories emerged: body image ideal, external influences, perception of body image, dieting, mechanisms for modification (diet, exercise, cosmetics) and sexual orientation. Health and aesthetic ideals appear less divorced for young men than women, offering some degree of protection from eating disorders. Nonetheless there is widespread body dissatisfaction. Media and social influences are powerful, particularly for single gay men, but the study suggests fewer differences than similarities between gay and straight men. Copyright (c) 2009 John Wiley & Sons, Ltd and Eating Disorders Association.

  15. Experimental and clinical studies of fast three-dimensional MR imaging of the heart

    International Nuclear Information System (INIS)

    Sato, Shuhei

    1999-01-01

    MRI has been utilized since its inception to study the anatomy and physiology of the heart. However, the sensitivity of MRI to motion has always posed a major challenge in imaging this organ. The purpose of this study was to develop a 3D MP-RAGE technique for the heart, and to apply it clinically. In the experimental study, data acquisition timing was discussed by normal volunteers. Changes in magnetization recovery time affected imaging contrast very little in the phantom study. Fourteen adults and 21 children were examined. In the adults, MP-RAGE images were rated as high in quality in the visual estimation. In the quantitative estimation, the images provided almost the same anatomical information as those of cine MRI. In the children, MP-RAGE was useful for cases of partial anomalous pulmonary venous drainage, particularly in the evaluation of abnormal pulmonary veins. The 3D MP-RAGE technique was useful in imaging the heart because it was possible to obtain continuous views in the same cardiac cycle and to reconstruct views from any direction after the examination. (author)

  16. Experimental and clinical studies of fast three-dimensional MR imaging of the heart

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Shuhei [Okayama Univ. (Japan). School of Medicine

    1999-07-01

    MRI has been utilized since its inception to study the anatomy and physiology of the heart. However, the sensitivity of MRI to motion has always posed a major challenge in imaging this organ. The purpose of this study was to develop a 3D MP-RAGE technique for the heart, and to apply it clinically. In the experimental study, data acquisition timing was discussed by normal volunteers. Changes in magnetization recovery time affected imaging contrast very little in the phantom study. Fourteen adults and 21 children were examined. In the adults, MP-RAGE images were rated as high in quality in the visual estimation. In the quantitative estimation, the images provided almost the same anatomical information as those of cine MRI. In the children, MP-RAGE was useful for cases of partial anomalous pulmonary venous drainage, particularly in the evaluation of abnormal pulmonary veins. The 3D MP-RAGE technique was useful in imaging the heart because it was possible to obtain continuous views in the same cardiac cycle and to reconstruct views from any direction after the examination. (author)

  17. Study of CT head scans using different voltages: image quality evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco de Freitas C, I.; Prata M, A. [Centro Federal de Educacao Tecnologica de Minas Gerais, Centro de Engenharia Biomedica, Av. Amazonas 5253, 30421-169 Nova Suica, Belo Horizonte, Minas Gerais (Brazil); Alonso, T. C. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Pampulha, Belo Horizonte, Minas Gerais (Brazil); Santana, P., E-mail: iarapfcorrea@gmail.com [Universidade Federal de Minas Gerais, Departamento de Anatomia e Imagem, Av. Prof. Alfredo Balena 190, 30130-100 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  18. Study of CT head scans using different voltages: image quality evaluation

    International Nuclear Information System (INIS)

    Pacheco de Freitas C, I.; Prata M, A.; Alonso, T. C.; Santana, P.

    2016-10-01

    Computed tomography (CT) was introduced to medical practice in 1972. It generates images recognized by high diagnostic potential. CT allows investigation of structures in the human body inaccessible by conventional image methods, replacing invasive methods in many cases. Noise is a kind of variation of brightness observed on CT images, and it is inherent to this method. The magnitude of the noise is determined by the standard deviation of CT numbers of a region of interest in a homogeneous material. The aim of this study is to analyze the noise in head CT images generated by different acquisition protocols using four voltage values. Five different scans were performed using a female Alderson phantom and their images were analyzed with the RadiAnt software. With the average HU values and standard deviation of each scan, the values of noise were calculated in some region of interest. The obtained noise values were compared and it was observed that the 140 kV voltage promotes the in the lower noise in the image, resulting in better image quality. The results also show that the parameters, such as voltage and current, can be adjusted so that the noise can be decreased. Thus, acquisition protocols may be adapted to produce images with diagnostic quality and lower doses in patient. (Author)

  19. Overlapping montage: a comparative study of mainstream film and moving-image installations

    OpenAIRE

    Ryan, Orla G.

    2005-01-01

    This dissertation develops a discussion on the need for a comparative approach to the study of film and moving- image installations. It addresses the lack of critical attention given to moving-image installations within film studies generally and academic teaching programmes in particular. The development of a comparative approach requires researching a number of interlinking and independent fields of study such as film studies, art history/criticism, photography, literary theory, critical th...

  20. a Comparative Case Study of Reflection Seismic Imaging Method

    Science.gov (United States)

    Alamooti, M.; Aydin, A.

    2017-12-01

    Seismic imaging is the most common means of gathering information about subsurface structural features. The accuracy of seismic images may be highly variable depending on the complexity of the subsurface and on how seismic data is processed. One of the crucial steps in this process, especially in layered sequences with complicated structure, is the time and/or depth migration of seismic data.The primary purpose of the migration is to increase the spatial resolution of seismic images by repositioning the recorded seismic signal back to its original point of reflection in time/space, which enhances information about complex structure. In this study, our objective is to process a seismic data set (courtesy of the University of South Carolina) to generate an image on which the Magruder fault near Allendale SC can be clearly distinguished and its attitude can be accurately depicted. The data was gathered by common mid-point method with 60 geophones equally spaced along an about 550 m long traverse over a nearly flat ground. The results obtained from the application of different migration algorithms (including finite-difference and Kirchhoff) are compared in time and depth domains to investigate the efficiency of each algorithm in reducing the processing time and improving the accuracy of seismic images in reflecting the correct position of the Magruder fault.

  1. High-Spatial- and High-Temporal-Resolution Dynamic Contrast-enhanced MR Breast Imaging with Sweep Imaging with Fourier Transformation: A Pilot Study

    Science.gov (United States)

    Benson, John C.; Idiyatullin, Djaudat; Snyder, Angela L.; Snyder, Carl J.; Hutter, Diane; Everson, Lenore I.; Eberly, Lynn E.; Nelson, Michael T.; Garwood, Michael

    2015-01-01

    Purpose To report the results of sweep imaging with Fourier transformation (SWIFT) magnetic resonance (MR) imaging for diagnostic breast imaging. Materials and Methods Informed consent was obtained from all participants under one of two institutional review board–approved, HIPAA-compliant protocols. Twelve female patients (age range, 19–54 years; mean age, 41.2 years) and eight normal control subjects (age range, 22–56 years; mean age, 43.2 years) enrolled and completed the study from January 28, 2011, to March 5, 2013. Patients had previous lesions that were Breast Imaging Reporting and Data System 4 and 5 based on mammography and/or ultrasonographic imaging. Contrast-enhanced SWIFT imaging was completed by using a 4-T research MR imaging system. Noncontrast studies were completed in the normal control subjects. One of two sized single-breast SWIFT-compatible transceiver coils was used for nine patients and five controls. Three patients and five control subjects used a SWIFT-compatible dual breast coil. Temporal resolution was 5.9–7.5 seconds. Spatial resolution was 1.00 mm isotropic, with later examinations at 0.67 mm isotropic, and dual breast at 1.00 mm or 0.75 mm isotropic resolution. Results Two nonblinded breast radiologists reported SWIFT image findings of normal breast tissue, benign fibroadenomas (six of six lesions), and malignant lesions (10 of 12 lesions) concordant with other imaging modalities and pathologic reports. Two lesions in two patients were not visualized because of coil field of view. The images yielded by SWIFT showed the presence and extent of known breast lesions. Conclusion The SWIFT technique could become an important addition to breast imaging modalities because it provides high spatial resolution at all points during the dynamic contrast-enhanced examination. © RSNA, 2014 PMID:25247405

  2. Pediatric Palliative Care: A Personal Story

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ... 35 Teen Cancer Stories | UCLA Daltrey/Townshend Teen & Young Adult Cancer Program - Duration: 11:08. UCLA Health ...

  3. Far-infrared fusion plasma diagnostics. Task IIIA. Final report

    International Nuclear Information System (INIS)

    Luhmann, N.C. Jr.

    1986-01-01

    The Task IIIA program at UCLA has been concerned with the development of innovative yet practical plasma diagnostic systems capable of providing detailed information essential to the success of the fusion program but not presently available within the fusion community. Historically, this has involved an initial development in the laboratory, followed by a test of feasibility on the Microtor tokamak prior to transfer of the technique/instrument to main line fusion devices. Strong emphasis has been placed upon the far-infrared (FIR) spectral region where novel diagnostic systems and technology have been developed and then distributed throughout the fusion program. The major diagnostics under development have been the measurement of plasma microturbulence and coherent modes via multichannel cw collective Thomson scattering, and the application of phase/polarization imaging techniques to provide accurate and detailed (>20 channel) electron density and current profiles not presently available using conventional methods. The eventual transfer of the above techniques to main line fusion devices is, of course, a major goal of the UCLA development program. The multichannel scattering development at UCLA was efficiently transferred to TEXT a few years ago. The apparatus has been employed to investigate the strong spectral and spatial asymmetries in the microturbulence uncovered through the unique multichannel and spatial scanning capabilities of the system. The scattering apparatus has also produced evidence for the ion pressure gradient driven eta/sub i/ modes thought responsible for anomalous transport in the edge regions of tokamak plasmas, as well as providing insight into the wave-wave coupling processes between various plasma modes

  4. The PROgnostic Value of unrequested Information in Diagnostic Imaging (PROVIDI) Study: rationale and design

    International Nuclear Information System (INIS)

    Gondrie, M. J. A.; Mali, W. P. Th. M.; Buckens, C. F. M.; Jacobs, P. C. A.; Grobbee, D. E.; Graaf, Y van der

    2010-01-01

    We describe the rationale for a new study examining the prognostic value of unrequested findings in diagnostic imaging. The deployment of more advanced imaging modalities in routine care means that such findings are being detected with increasing frequency. However, as the prognostic significance of many types of unrequested findings is unknown, the optimal response to such findings remains uncertain and in many cases an overly defensive approach is adopted, to the detriment of patient-care. Additionally, novel and promising image findings that are newly available on many routine scans cannot be used to improve patient care until their prognostic value is properly determined. The PROVIDI study seeks to address these issues using an innovative multi-center case-cohort study design. PROVIDI is to consist of a series of studies investigating specific, selected disease entities and clusters. Computed Tomography images from the participating hospitals are reviewed for unrequested findings. Subsequently, this data is pooled with outcome data from a central population registry. Study populations consist of patients with endpoints relevant to the (group of) disease(s) under study along with a random control sample from the cohort. This innovative design allows PROVIDI to evaluate selected unrequested image findings for their true prognostic value in a series of manageable studies. By incorporating unrequested image findings and outcomes data relevant to patients, truly meaningful conclusions about the prognostic value of unrequested and emerging image findings can be reached and used to improve patient-care.

  5. The impact of brand experience on attitudes and brand image : A quantitative study

    OpenAIRE

    Isotalo, Anni; Watanen, Samu

    2015-01-01

    Research questions: How to create an engaging brand experience in marketing context? How does an engaging brand experience affect consumer attitudes and brand image? Purpose of the study: The authors propose that the relationship between brand experience and formation of brand loyalty can be mediated by brand affect: positive attitude and brand image. The study discovers the components of an engaging brand experience and indicates their effect on consumer attitudes and brand image. Conclusion...

  6. Improving the image quality of contrast-enhanced MR angiography by automated image registration: A prospective study in peripheral arterial disease of the lower extremities

    International Nuclear Information System (INIS)

    Menke, Jan

    2010-01-01

    Objective: If a patient has moved during digital subtraction angiography (DSA), manual pixel shift can improve the image quality. This study investigated whether such image registration can also improve the quality of contrast-enhanced magnetic resonance angiography (MRA) in patients with peripheral arterial disease of the lower extremities. Materials and methods: 404 leg MRAs of patients likely to have peripheral artery disease were included in this prospective study. The standard non-registered MRAs were compared to automatically linear, affine and warp registered MRAs by four image quality parameters, including the vessel detection probability (VDP) in maximum intensity projection (MIP) images and contrast-to-noise ratios (CNR). The different registration types were compared by analysis of variance. Results: All studied image quality parameters showed similar trends. Generally, registration improved the leg MRA quality significantly (P < 0.05). The 12% of lower legs with a body shift of 1 mm or more showed the highest gain in image quality when using linear registration instead of no registration, with an average VDP gain of 20-49%. Warp registration improved the image quality slightly further. Conclusion: Automated image registration can improve the MRA image quality especially in the lower legs, which is comparable to the effect of pixel shift in DSA.

  7. Studies on polyaspartamide gadolinium complexes as potential magnetic resonance imaging contrast agents

    International Nuclear Information System (INIS)

    Yan Guoping; Liu Maili; Li Liyun

    2005-01-01

    Purpose: A series of polyaspartamide gadolinium complexes containing pyridoxamine groups were studied as the potential magnetic resonance imaging (MRI) contrast agents for liver enhancement. Methods: These polyaspartamide gadolinium complexes were prepared and evaluated by relaxivity, acute toxicity studies and magnetic resonance imaging of the liver in rats. Results: These polyaspartamide gadolinium complexes have higher relaxation effectiveness than that of the clinically used gadolinium diethylenetriaminepentaacetic acid and possess the low intravenous acute toxicities to Institute for Cancer Research (ICR) mice. Magnetic resonance imaging of the liver in rats indicated that they greatly enhance the contrast of magnetic resonance images and provide prolonged intravascular duration in the liver. Conclusion: These results indicated that the polyaspartamide gadolinium complexes containing pyridoxamine groups could be considered as the appropriate MRI contrast agents for liver enhancement

  8. The UCLA hadronization model and Pt correlation study at √s = 29 GeV

    International Nuclear Information System (INIS)

    Chun, Sebong.

    1989-01-01

    With only longitudinal phase space, a linear confining quark potential, and Clebsch-Gordon coefficients, the authors demonstrate remarkable agreement with a large body of data. This involves only two parameters of a modified Lund symmetric fragmentation function a, b and three coherent lengths: the number of hadrons over which the transverse momentum P t is required to be compensated, the degree of the spin correlation between a diquark and its partner anti-diquark in baryon and anti-baryon production, and the degree of suppression of successive mesons created between a baryon and anti-baryon (which comes from the uncertainty principle). These coherent lengths have a common fundamental characteristic, namely, the propagation length of information along the chain of produced hadrons. As a separate effort to probe the propagation length of P t , we studied the correlations in momentum transverse to the event jet-axis for neighboring particles close in rapidity, which reflect the tendency of back-to-back production of the hadron pairs. He found indications of interesting correlations, but that a larger data sample is needed for definitive understanding of the area

  9. Drug release into hydrogel-based subcutaneous surrogates studied by UV imaging

    DEFF Research Database (Denmark)

    Ye, Fengbin; Larsen, Susan Weng; Yaghmur, Anan

    2012-01-01

    of the performance of drug delivery systems based on in vitro experiments. The objective of this study was to evaluate a UV imaging-based method for real-time characterization of the release and transport of piroxicam in hydrogel-based subcutaneous tissue mimics/surrogates. Piroxicam partitioning from medium chain...... upon the injection of aqueous or MCT solutions into an agarose-based hydrogel were investigated by UV imaging. The spatial distribution of piroxicam around the injection site in the gel matrix was monitored in real-time. The disappearance profiles of piroxicam from the injected aqueous solution were...... obtained. This study shows that the UV imaging methodology has considerable potential for characterizing transport properties in hydrogels, including monitoring the real-time spatial concentration distribution in vitro after administration by injection....

  10. Data quality in diffusion tensor imaging studies of the preterm brain: a systematic review.

    Science.gov (United States)

    Pieterman, Kay; Plaisier, Annemarie; Govaert, Paul; Leemans, Alexander; Lequin, Maarten H; Dudink, Jeroen

    2015-08-01

    To study early neurodevelopment in preterm infants, evaluation of brain maturation and injury is increasingly performed using diffusion tensor imaging, for which the reliability of underlying data is paramount. To review the literature to evaluate acquisition and processing methodology in diffusion tensor imaging studies of preterm infants. We searched the Embase, Medline, Web of Science and Cochrane databases for relevant papers published between 2003 and 2013. The following keywords were included in our search: prematurity, neuroimaging, brain, and diffusion tensor imaging. We found 74 diffusion tensor imaging studies in preterm infants meeting our inclusion criteria. There was wide variation in acquisition and processing methodology, and we found incomplete reporting of these settings. Nineteen studies (26%) reported the use of neonatal hardware. Data quality assessment was not reported in 13 (18%) studies. Artefacts-correction and data-exclusion was not reported in 33 (45%) and 18 (24%) studies, respectively. Tensor estimation algorithms were reported in 56 (76%) studies but were often suboptimal. Diffusion tensor imaging acquisition and processing settings are incompletely described in current literature, vary considerably, and frequently do not meet the highest standards.

  11. Comparative study of protoporphyrin IX fluorescence image enhancement methods to improve an optical imaging system for oral cancer detection

    Science.gov (United States)

    Jiang, Ching-Fen; Wang, Chih-Yu; Chiang, Chun-Ping

    2011-07-01

    Optoelectronics techniques to induce protoporphyrin IX fluorescence with topically applied 5-aminolevulinic acid on the oral mucosa have been developed to noninvasively detect oral cancer. Fluorescence imaging enables wide-area screening for oral premalignancy, but the lack of an adequate fluorescence enhancement method restricts the clinical imaging application of these techniques. This study aimed to develop a reliable fluorescence enhancement method to improve PpIX fluorescence imaging systems for oral cancer detection. Three contrast features, red-green-blue reflectance difference, R/B ratio, and R/G ratio, were developed first based on the optical properties of the fluorescence images. A comparative study was then carried out with one negative control and four biopsy confirmed clinical cases to validate the optimal image processing method for the detection of the distribution of malignancy. The results showed the superiority of the R/G ratio in terms of yielding a better contrast between normal and neoplastic tissue, and this method was less prone to errors in detection. Quantitative comparison with the clinical diagnoses in the four neoplastic cases showed that the regions of premalignancy obtained using the proposed method accorded with the expert's determination, suggesting the potential clinical application of this method for the detection of oral cancer.

  12. A Study of NetCDF as an Approach for High Performance Medical Image Storage

    International Nuclear Information System (INIS)

    Magnus, Marcone; Prado, Thiago Coelho; Von Wangenhein, Aldo; De Macedo, Douglas D J; Dantas, M A R

    2012-01-01

    The spread of telemedicine systems increases every day. The systems and PACS based on DICOM images has become common. This rise reflects the need to develop new storage systems, more efficient and with lower computational costs. With this in mind, this article discusses a study for application in NetCDF data format as the basic platform for storage of DICOM images. The study case comparison adopts an ordinary database, the HDF5 and the NetCDF to storage the medical images. Empirical results, using a real set of images, indicate that the time to retrieve images from the NetCDF for large scale images has a higher latency compared to the other two methods. In addition, the latency is proportional to the file size, which represents a drawback to a telemedicine system that is characterized by a large amount of large image files.

  13. [The alcoholic's self-image: a comparative study between men and women].

    Science.gov (United States)

    Aubry, C; Gay, M-C; Romo, L; Joffre, S

    2004-01-01

    Self-image is a central problem in alcoholism. Most theories about the relationships between the self-image of alcoholics and their behaviour have been derived from -clinical observations rather than empirical research. Most observations have pointed out that alcoholics are prone to underevaluation of themselves and that low self-image is the basis of much of the problem drinker's behaviour. All the research on self-image has concluded that alcoholics have a lower self-image than non-alcoholics. Some empirical research has been conducted on the self-image of alcoholics; it has, however, been carried out only a few times, restricted to small samples, and concerned with a limited number of aspects of self-image. Moreover, most of these studies are not recent, and it seems that this area of research is not well covered. Even though the hypothesis of a bad self-image in alcoholics was validated by various older studies, the representation of alcoholism has since changed. Because of this evolution, the ways in which the disease has been viewed have changed. One can question to what extent changes in society can influence the self-image of alcoholics. This question seems all the more pertinent for alcoholic women, given the evolution of the female condition since the Seventies. The objectives of this study are to evaluate the self-image of alcoholics and non-alcoholics, and to compare the self-image of male and female alcoholics. Our hypotheses are that: 1) the self-image of an alcoholic is more negative than that of a non-alcoholic, and that: 2) female alcoholics have a more negative self-image than male alcoholics. Two groups of 30 subjects each were made up: a group of alcoholics recruited in an alcohol-dependency unit and a group of non-alcoholics recruited in a public place. The comparison of socio-demographic data between the alcoholic group and the control group does not show a significant difference except for age and level of schooling. The average age of the

  14. [The professional self and hetero image among public health nurses: a study of social representations].

    Science.gov (United States)

    Gomes, Antonio Marcos Tosoli; Oliveira, Denize Cristina de

    2005-01-01

    The object of this study is the professional image constructed by public health nurses and the objective is to describe and analyze the professional images present in the representations of nurses who deliver direct care to this clientele. The theoretical-methodological reference framework adopted was Social Representations Theory. A qualitative study was developed in Petrópolis-Rio de Janeiro/Brazil, through in-depth interviews with 30 nurses. Alceste 4.5 software was used for the lexical analysis. The results reveal the existence of a professional self-image with three groups of meanings: being a reference for the team, the non-specific image and the image of plaster; and a professional hetero-image with four groups of meanings: administrator, invisible, positive image and superposition. The study of the professional image reflects the construction of the nurse's identity in itself and emphasizes Social Representations Theory as a useful tool for nursing research development.

  15. Brain connectivity study of joint attention using frequency-domain optical imaging technique

    Science.gov (United States)

    Chaudhary, Ujwal; Zhu, Banghe; Godavarty, Anuradha

    2010-02-01

    Autism is a socio-communication brain development disorder. It is marked by degeneration in the ability to respond to joint attention skill task, from as early as 12 to 18 months of age. This trait is used to distinguish autistic from nonautistic populations. In this study, diffuse optical imaging is being used to study brain connectivity for the first time in response to joint attention experience in normal adults. The prefrontal region of the brain was non-invasively imaged using a frequency-domain based optical imager. The imaging studies were performed on 11 normal right-handed adults and optical measurements were acquired in response to joint-attention based video clips. While the intensity-based optical data provides information about the hemodynamic response of the underlying neural process, the time-dependent phase-based optical data has the potential to explicate the directional information on the activation of the brain. Thus brain connectivity studies are performed by computing covariance/correlations between spatial units using this frequency-domain based optical measurements. The preliminary results indicate that the extent of synchrony and directional variation in the pattern of activation varies in the left and right frontal cortex. The results have significant implication for research in neural pathways associated with autism that can be mapped using diffuse optical imaging tools in the future.

  16. Study of image reconstruction for terahertz indirect holography with quasi-optics receiver.

    Science.gov (United States)

    Gao, Xiang; Li, Chao; Fang, Guangyou

    2013-06-01

    In this paper, an indirect holographic image reconstruction algorithm was studied for terahertz imaging with a quasi-optics receiver. Based on the combination of the reciprocity principle and modified quasi-optics theory, analytical expressions of the received spatial power distribution and its spectrum are obtained for the interference pattern of target wave and reference wave. These results clearly give the quantitative relationship between imaging quality and the parameters of a Gaussian beam, which provides a good criterion for terahertz quasi-optics transceivers design in terahertz off-axis holographic imagers. To validate the effectiveness of the proposed analysis method, some imaging results with a 0.3 THz prototype system are shown based on electromagnetic simulation.

  17. A study of images of Projective Angles of pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Wang Jue [Beijing Anzhen Hospital, Beijing (China); Zhaoqi, Zhang [Beijing Anzhen Hospital, Beijing (China)], E-mail: zhaoqi5000@vip.sohu.com; Yu Wei; Miao Cuilian; Yan Zixu; Zhao Yike [Beijing Anzhen Hospital, Beijing (China)

    2009-09-15

    Aims: In images of magnetic resonance and computed tomography (CT) there are visible angles between pulmonary veins and the coronary, transversal or sagittal section of body. In this study these angles are measured and defined as Projective Angles of pulmonary veins. Several possible influential factors and characters of distribution are studied and analyzed for a better understanding of this imaging anatomic character of pulmonary veins. And it could be the anatomic base of adjusting correctly the angle of the central X-ray of the angiography of pulmonary veins undergoing the catheter ablation of atrial fibrillation (AF). Method: Images of contrast enhanced magnetic resonance angiography (CEMRA) and contrast enhanced computer tomography (CECT) of the left atrium and pulmonary veins of 137 health objects and patients with atrial fibrillation (AF) are processed with the technique of post-processing, and Projective Angles to the coronary and transversal sections are measured and analyzed statistically. Result: Project Angles of pulmonary veins are one of real and steady imaging anatomic characteristics of pulmonary veins. The statistical distribution of variables is relatively concentrated, with a fairly good representation of average value. It is possible to improve the angle of the central X-ray according to the average value in the selective angiography of pulmonary veins undergoing the catheter ablation of AF.

  18. Fundamental studies of superconductors using scanning magnetic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kirtley, J R [Center for Probing the Nanoscale, Stanford University, Stanford, CA (United States)

    2010-12-01

    In this review I discuss the application of scanning magnetic imaging to fundamental studies of superconductors, concentrating on three scanning magnetic microscopies-scanning SQUID microscopy (SSM), scanning Hall bar microscopy (SHM) and magnetic force microscopy (MFM). I briefly discuss the history, sensitivity, spatial resolution, invasiveness and potential future developments of each technique. I then discuss a selection of applications of these microscopies. I start with static imaging of magnetic flux: an SSM study provides deeper understanding of vortex trapping in narrow strips, which are used to reduce noise in superconducting circuitry. Studies of vortex trapping in wire lattices, clusters and arrays of rings and nanoholes show fascinating ordering effects. The cuprate high-T{sub c} superconductors are shown to have predominantly d-wave pairing symmetry by magnetic imaging of the half-integer flux quantum effect. Arrays of superconducting rings act as a physical analog for the Ising spin model, with the half-integer flux quantum effect helping to eliminate one source of disorder in antiferromagnetic arrangements of the ring moments. Tests of the interlayer tunneling model show that the condensation energy available from this mechanism cannot account for the high critical temperatures observed in the cuprates. The strong divergence in the magnetic fields of Pearl vortices allows them to be imaged using SSM, even for penetration depths of a millimeter. Unusual vortex arrangements occur in samples comparable in size to the coherence length. Spontaneous magnetization is not observed in Sr{sub 2}RuO{sub 4}, which is believed to have p{sub x} {+-} ip{sub y} pairing symmetry, although effects hundreds of times bigger than the sensitivity limits had been predicted. However, unusual flux trapping is observed in this superconductor. Finally, unusual flux arrangements are also observed in magnetic superconductors. I then turn to vortex dynamics: imaging of vortices

  19. Fundamental studies of superconductors using scanning magnetic imaging

    Science.gov (United States)

    Kirtley, J. R.

    2010-12-01

    In this review I discuss the application of scanning magnetic imaging to fundamental studies of superconductors, concentrating on three scanning magnetic microscopies—scanning SQUID microscopy (SSM), scanning Hall bar microscopy (SHM) and magnetic force microscopy (MFM). I briefly discuss the history, sensitivity, spatial resolution, invasiveness and potential future developments of each technique. I then discuss a selection of applications of these microscopies. I start with static imaging of magnetic flux: an SSM study provides deeper understanding of vortex trapping in narrow strips, which are used to reduce noise in superconducting circuitry. Studies of vortex trapping in wire lattices, clusters and arrays of rings and nanoholes show fascinating ordering effects. The cuprate high-Tc superconductors are shown to have predominantly d-wave pairing symmetry by magnetic imaging of the half-integer flux quantum effect. Arrays of superconducting rings act as a physical analog for the Ising spin model, with the half-integer flux quantum effect helping to eliminate one source of disorder in antiferromagnetic arrangements of the ring moments. Tests of the interlayer tunneling model show that the condensation energy available from this mechanism cannot account for the high critical temperatures observed in the cuprates. The strong divergence in the magnetic fields of Pearl vortices allows them to be imaged using SSM, even for penetration depths of a millimeter. Unusual vortex arrangements occur in samples comparable in size to the coherence length. Spontaneous magnetization is not observed in Sr2RuO4, which is believed to have px ± ipy pairing symmetry, although effects hundreds of times bigger than the sensitivity limits had been predicted. However, unusual flux trapping is observed in this superconductor. Finally, unusual flux arrangements are also observed in magnetic superconductors. I then turn to vortex dynamics: imaging of vortices in rings of highly underdoped

  20. Cone-beam volume CT breast imaging: Feasibility study

    International Nuclear Information System (INIS)

    Chen Biao; Ning Ruola

    2002-01-01

    X-ray projection mammography, using a film/screen combination, or digital techniques, has proven to be the most effective imaging modality currently available for early detection of breast cancer. However, the inherent superimposition of structures makes a small carcinoma (a few millimeters in size) difficult to detect when it is occult or in dense breasts, leading to a high false-positive biopsy rate. Cone-beam x-ray-projection-based volume imaging using flat panel detectors (FPDs) may allow obtaining three-dimensional breast images, resulting in more accurate diagnosis of structures and patterns of lesions while eliminating the hard compression of breasts. This article presents a novel cone-beam volume computed tomographic breast imaging (CBVCTBI) technique based on the above techniques. Through a variety of computer simulations, the key issues of the system and imaging techniques were addressed, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissue and lesions, x-ray setting techniques, the absorbed dose estimation, and the quantitative effect of x-ray scattering on image quality. The preliminary simulation results support the proposed CVBCTBI modality for breast imaging in respect to its feasibility and practicability. The absorbed dose level is comparable to that of current mammography and will not be a prominent problem for this imaging technique. Compared to conventional mammography, the proposed imaging technique with isotropic spatial resolution will potentially provide significantly better low-contrast detectability of breast tumors and more accurate location of breast lesions

  1. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  2. Nuclear medicine imaging instrumentations for molecular imaging

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Song, Tae Yong; Choi, Yong

    2004-01-01

    Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging

  3. Autism Spectrum Disorder Reclassified: A Second Look at the 1980s Utah/UCLA Autism Epidemiologic Study

    Science.gov (United States)

    Miller, Judith S.; Bilder, Deborah; Farley, Megan; Coon, Hilary; Pinborough-Zimmerman, Judith; Jenson, William; Rice, Catherine E.; Fombonne, Eric; Pingree, Carmen B.; Ritvo, Edward; Ritvo, Riva-Ariella; McMahon, William M.

    2013-01-01

    The purpose of the present study was to re-examine diagnostic data from a state-wide autism prevalence study (n = 489) conducted in the 1980s to investigate the impact of broader diagnostic criteria on autism spectrum disorder (ASD) case status. Sixty-four (59%) of the 108 originally "Diagnosed Not Autistic" met the current ASD case definition.…

  4. UV imaging for in vitro dissolution and release studies: Initial experiences

    DEFF Research Database (Denmark)

    Østergaard, Jesper; Lenke, James; Jensen, Sabrine Smedegaard

    2014-01-01

    UV imaging has recently been introduced as a method in drug dissolution and release testing. Spatially and temporally resolved mapping of drug oncentrations in a 7 × 9 mm imaging area provides new opportunities for visualization and study of drug dissolution and release. This review describes...... in hydrogels with relevance for characterization of parenteral depots. UV imaging may be of particular use when the amounts of material are sparse and detailed insights into dissolution and release processes are required, that is in solid form screening, preformulation, and early drug development....

  5. A study on the central plane of image layer in panoramic radiograph

    International Nuclear Information System (INIS)

    Lee, Moon Bai; Park, Chang Seo

    1986-01-01

    The purpose of this investigation was to locate the plane of the image layer on the panoramic machine relative to a specific point on the machine. In the study of the central plane of the image layer of panoramic radiograph, using the Morrita Company PANEX-EC a series of 33 exposures were taken with the 4-5 experimental pins placed in the holes of the plastic model plate, then evaluated by human eye. The author analyzed the central plane of the image layer by Mitutoy-A-221 and calculated horizontal and vertical magnification ratio in central plane of the image layer determined experimentally. The results were as follows: 1. The location of the central plane of the image layer determined experimentally was to lateral compared with manufactural central plane. 2. Horizontal magnification ratio in the central plane of image layer determined experimentally was 9.25%. 3. Vertical magnification ratio in the central plane of the image layer determined experimentally was 9.17%.

  6. Leon Knopoff (1926-2011)

    Science.gov (United States)

    Davis, Paul; Jackson, David; Gilbert, Freeman

    2011-06-01

    Leon Knopoff died at his home in Sherman Oaks, Calif., on 20 January 2011 at the age of 85. A man of wide-ranging talents, he had the rare distinction of being simultaneously a professor of physics, a professor of geophysics, and a research musicologist at the University of California, Los Angeles (UCLA). As an undergraduate he studied electrical engineering and obtained his Ph.D. in physics and mathematics at the California Institute of Technology (Caltech) in 1949. He was recruited to the Institute of Geophysics (now the Institute of Geophysics and Planetary Physics) at UCLA in 1950 by Louis Slichter, where he became a professor of geophysics in 1957 and of geophysics and physics in 1961. He became a research musicologist in the UCLA Institute of Ethnomusicology soon after it was formed in 1960. Other appointments included faculty positions at Miami University in Ohio (1948-1950) and Caltech (1962-1963) and visiting appointments at Cambridge, Karlsruhe, Harvard, Santiago, Trieste, and Venice.

  7. Autism Spectrum Disorder Reclassified: A Second Look at the 1980s Utah/UCLA Autism Epidemiologic Study

    Science.gov (United States)

    Miller, Judith S.; Farley, Megan; Coon, Hilary; Pinborough-Zimmerman, Judith; Jenson, William; Rice, Catherine E.; Fombonne, Eric; Pingree, Carmen B.; Ritvo, Edward; Ritvo, Riva-Ariella; McMahon, William M.

    2015-01-01

    The purpose of the present study was to re-examine diagnostic data from a state-wide autism prevalence study (n = 489) conducted in the 1980s to investigate the impact of broader diagnostic criteria on autism spectrum disorder (ASD) case status. Sixty-four (59 %) of the 108 originally “Diagnosed Not Autistic” met the current ASD case definition. The average IQ estimate in the newly identified group (IQ = 35.58; SD = 23.01) was significantly lower than in the original group (IQ = 56.19 SD = 21.21; t = 5.75; p autism with intellectual disability. The current analysis puts this historic work into context and highlights differences in ascertainment between epidemiological studies performed decades ago and those of today. PMID:22696195

  8. Current studies and future perspectives of synchrotron radiation imaging trials in human patients

    Energy Technology Data Exchange (ETDEWEB)

    Longo, Renata, E-mail: renata.longo@ts.infn.it [Department of Physics, University of Trieste, via Valerio 2 3410 Trieste (Italy); INFN- sezione di Trieste, via Valerio 2 3410 Trieste (Italy)

    2016-02-11

    The coherent and monochromatic x-ray beams available at the synchrotron radiation (SR) laboratories are ideal tools for the development and the initial application of new imaging techniques. In the present paper the history of the clinical studies in k-edge subtraction imaging with SR is summarized, including coronary angiography and bronchography. The results of the recent trial in phase-contrast mammography at Elettra (Trieste, Italy) are discussed, in order to assess the clinical impact of the new imaging modality and the potential interest in its translation to clinical practice. The direct measurement of linear attenuation coefficient obtained during the SR mammography trial is also discussed. The new program of phase-contrast breast CT under development at Elettra is presented. Recently, 3D breast imaging (tomosynthesis and cone beam breast CT) has been introduced in clinical practice with significant improvement in diagnostic accuracy. The aim of this research is to study the contribution of the phase-contrast to the image quality of breast CT. Increasing the image quality of the x-ray medical images at the level of the results obtained at the SR laboratories is highly desirable, hence the promising techniques for the translation of the phase-contrast imaging to the hospitals are briefly discussed.

  9. Current studies and future perspectives of synchrotron radiation imaging trials in human patients

    International Nuclear Information System (INIS)

    Longo, Renata

    2016-01-01

    The coherent and monochromatic x-ray beams available at the synchrotron radiation (SR) laboratories are ideal tools for the development and the initial application of new imaging techniques. In the present paper the history of the clinical studies in k-edge subtraction imaging with SR is summarized, including coronary angiography and bronchography. The results of the recent trial in phase-contrast mammography at Elettra (Trieste, Italy) are discussed, in order to assess the clinical impact of the new imaging modality and the potential interest in its translation to clinical practice. The direct measurement of linear attenuation coefficient obtained during the SR mammography trial is also discussed. The new program of phase-contrast breast CT under development at Elettra is presented. Recently, 3D breast imaging (tomosynthesis and cone beam breast CT) has been introduced in clinical practice with significant improvement in diagnostic accuracy. The aim of this research is to study the contribution of the phase-contrast to the image quality of breast CT. Increasing the image quality of the x-ray medical images at the level of the results obtained at the SR laboratories is highly desirable, hence the promising techniques for the translation of the phase-contrast imaging to the hospitals are briefly discussed.

  10. A Study on Analysis of EEG Caused by Grating Stimulation Imaging

    Science.gov (United States)

    Urakawa, Hiroshi; Nishimura, Toshihiro; Tsubai, Masayoshi; Itoh, Kenji

    Recently, many researchers have studied a visual perception. Focus is attended to studies of the visual perception phenomenon by using the grating stimulation images. The previous researches have suggested that a subset of retinal ganglion cells responds to motion in the receptive field center, but only if the wider surround moves with a different trajectory. We discuss the function of human retina, and measure and analysis EEG(electroencephalography) of a normal subject who looks on grating stimulation images. We confirmed the visual perception of human by EEG signal analysis. We also have obtained that a sinusoidal grating stimulation was given, asymmetry was observed the α wave element in EEG of the symmetric part in a left hemisphere and a right hemisphere of the brain. Therefore, it is presumed that projected image is even when the still picture is seen and the image projected onto retinas of right and left eyes is not even for the dynamic scene. It evaluated it by taking the envelope curve for the detected α wave, and using the average and standard deviation.

  11. Images of flight nursing in Australia: A study using institutional ethnography.

    Science.gov (United States)

    Brideson, Genevieve; Willis, Eileen; Mayner, Lidia; Chamberlain, Diane J

    2016-03-01

    Pictures speak a thousand words. The traditional romantic image of an Australian aeromedical service is a male doctor and male pilot, out to rescue the male stockman from the red dust of the Australian outback. However, the reality is considerably different, particularly in the current context of the Australian healthcare system. This paper examines the images of flight nursing using a critical lens. The images are derived from popular literature sources from the early 1940s through to the present. A textual analysis of the images of flight nursing using the methodology of institutional ethnography reveals a number of themes including the glamorous, the romantic, and the heroic nurse. This study illustrates that the way these nurses are portrayed within popular literature mirrors the Australian cultural ethic of heroic bush pioneer, yet at the same time the work these nurses do is undervalued by various omissions and misrepresentations. The results from this study have the potential to significantly improve recognition of the work performed by flight nurses and to challenge incorrect cultural myths. © 2015 Wiley Publishing Asia Pty Ltd.

  12. Delayed hyperacute rejection in a patient who developed clostridium difficile infection after ABO-incompatible kidney transplantation

    Directory of Open Access Journals (Sweden)

    Gerald S Lipshutz

    2010-11-01

    Full Text Available Gerald S Lipshutz1, Elaine F Reed2, Phuong-Chi Pham3, Jeffrey M Miller4, Jennifer S Singer5, Gabriel M Danovitch6, Alan H Wilkinson6, Dean W Wallace7, Suzanne McGuire6, Phuong-Truc Pham8, Phuong-Thu Pham61Department of Surgery, Kidney and Pancreas Transplant Program, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA; 2Department of Pathology and Laboratory Medicine-Immunogenetics, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA; 3Department of Medicine, Nephrology Division, UCLA-Olive View Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA; 4Department of Medicine, Hematology Oncology Division, UCLA-Olive View Medical Center, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA; 5Department of Surgery and Urology, Kidney and Pancreas Transplant Program, 6Department of Medicine, Nephrology Division, Kidney and Pancreas Transplant Program, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA; 7Department of Pathology and Laboratory Medicine, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA; 8Department of Science, Penn State University, Worthington-Scranton, Dunmore, PA, USAAbstract: Over the past decade ABO incompatible transplantation has emerged as an important potential source for increasing living kidney transplantation in selected transplant centers. Early reports suggest that patients who have elevated serum anti-blood group antibody titers (anti-A/B before transplantation and a rebound antibody production after antibody removal may be at high immunological risk. With currently available immune modulation protocols and immunosuppressive therapy, excellent short- and long-term patient and graft survival rates have been achieved even in those with high anti-A/B antibody titers before plasmapheresis or immunoadsorption. Nonetheless, acute infection with an organism possessing surface markers analogous to blood group antigens such as carbohydrate structures on

  13. Quantitative imaging of the human upper airway: instrument design and clinical studies

    Science.gov (United States)

    Leigh, M. S.; Armstrong, J. J.; Paduch, A.; Sampson, D. D.; Walsh, J. H.; Hillman, D. R.; Eastwood, P. R.

    2006-08-01

    Imaging of the human upper airway is widely used in medicine, in both clinical practice and research. Common imaging modalities include video endoscopy, X-ray CT, and MRI. However, no current modality is both quantitative and safe to use for extended periods of time. Such a capability would be particularly valuable for sleep research, which is inherently reliant on long observation sessions. We have developed an instrument capable of quantitative imaging of the human upper airway, based on endoscopic optical coherence tomography. There are no dose limits for optical techniques, and the minimally invasive imaging probe is safe for use in overnight studies. We report on the design of the instrument and its use in preliminary clinical studies, and we present results from a range of initial experiments. The experiments show that the instrument is capable of imaging during sleep, and that it can record dynamic changes in airway size and shape. This information is useful for research into sleep disorders, and potentially for clinical diagnosis and therapies.

  14. Development of aptamer based HIV-1 entry inhibitor prophylactic drugs

    CSIR Research Space (South Africa)

    London, G

    2013-08-01

    Full Text Available proliferation assay and mapped their epitopes on gp120 by site directed mutagenesis. UCLA1 and CSIR1.1 neutralized infectivity of 79 % and 84 % pseudotyped viruses, respectively. UCLA1, further inhibited > 60 % of clinical isolates. We noted that, aptamers...

  15. Multimodality molecular imaging - from target description to clinical studies

    International Nuclear Information System (INIS)

    Schober, O.; Rahbar, K.; Riemann, B.

    2009-01-01

    This highlight lecture was presented at the closing session of the Annual Congress of the European Association of Nuclear Medicine (EANM) in Munich on 15 October 2008. The Congress was a great success: there were more than 4,000 participants, and 1,597 abstracts were submitted. Of these, 1,387 were accepted for oral or poster presentation, with a rejection rate of 14%. In this article a choice was made from 100 of the 500 lectures which received the highest scores by the scientific review panel. This article outlines the major findings and trends at the EANM 2008, and is only a brief summary of the large number of outstanding abstracts presented. Among the great number of oral and poster presentations covering nearly all fields of nuclear medicine some headlines have to be defined highlighting the development of nuclear medicine in the 21st century. This review focuses on the increasing impact of molecular and multimodality imaging in the field of nuclear medicine. In addition, the question may be asked as to whether the whole spectrum of nuclear medicine is nothing other than molecular imaging and therapy. Furthermore, molecular imaging will and has to go ahead to multimodality imaging. In view of this background the review was structured according to the single steps of molecular imaging, i.e. from target description to clinical studies. The following topics are addressed: targets, radiochemistry and radiopharmacy, devices and computer science, animals and preclinical evaluations, and patients and clinical evaluations. (orig.)

  16. Imaging studies of crystalline arthritides

    Directory of Open Access Journals (Sweden)

    G. Garlaschi

    2012-01-01

    Full Text Available Gout, calcium pyrophosphate dihydrate (CPPD deposition disease, and calcium hydroxyapatite deposition disease (HADD are the three most common crystal-induced arthropathies. Multimodality imaging may help in their diagnosis, and is useful for a precise and comprehensive assessment and grading of the related osteoarticular damage. Plain film radiography, due to its low cost and wide availability, is the first imaging technique to be used in crystal deposition diseases, providing well-known and specific findings for CPPD deposition disease and HADD, while it may undergrade the early osteoarticular lesions in gouty patients. Ultrasonography (US is a radiation-free approach that accurately depicts crystal deposits in cartilage, peri- and intra-articular soft tissues, but it does not give a panoramic view of the affected joints. Cross-sectional imaging techniques can examine crystal deposits in the spine and axial joints. CT has the potential to distinguish monosodium urate (MSU crystals from calcium containing crystals, due to their different attenuation values. MRI may demonstrate synovitis, erosions and bone marrow edema in gouty patients and it may differentiate tophi from other soft tissue nodules due to its high contrast resolution and power of tissue characterization.

  17. CT Image Contrast of High-Z Elements: Phantom Imaging Studies and Clinical Implications.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Torres, Andrew S; Bonitatibus, Peter J; Yeh, Benjamin M

    2016-03-01

    To quantify the computed tomographic (CT) image contrast produced by potentially useful contrast material elements in clinically relevant imaging conditions. Equal mass concentrations (grams of active element per milliliter of solution) of seven radiodense elements, including iodine, barium, gadolinium, tantalum, ytterbium, gold, and bismuth, were formulated as compounds in aqueous solutions. The compounds were chosen such that the active element dominated the x-ray attenuation of the solution. The solutions were imaged within a modified 32-cm CT dose index phantom at 80, 100, 120, and 140 kVp at CT. To simulate larger body sizes, 0.2-, 0.5-, and 1.0-mm-thick copper filters were applied. CT image contrast was measured and corrected for measured concentrations and presence of chlorine in some compounds. Each element tested provided higher image contrast than iodine at some tube potential levels. Over the range of tube potentials that are clinically practical for average-sized and larger adults-that is, 100 kVp and higher-barium, gadolinium, ytterbium, and tantalum provided consistently increased image contrast compared with iodine, respectively demonstrating 39%, 56%, 34%, and 24% increases at 100 kVp; 39%, 66%, 53%, and 46% increases at 120 kVp; and 40%, 72%, 65%, and 60% increases at 140 kVp, with no added x-ray filter. The consistently high image contrast produced with 100-140 kVp by tantalum compared with bismuth and iodine at equal mass concentration suggests that tantalum could potentially be favorable for use as a clinical CT contrast agent.

  18. Large-field image intensifiers versus conventional chest radiography: ROC study with simulated interstitial disease

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Waes, P.F.G.M.

    1988-01-01

    Two image intensifier tubes have recently been introduced whose large imaging area makes them suitable for chest imaging (Phillips Pulmodiagnost TLX slit II and Siemens TX 57 large entrance field II). Both modalities present a 10 x 10-cm hard copy image to the radiologist. A receiver operating characteristic (ROC) curve study with simulated interstitial disease was performed to compare the image quality of these image intensifiers with conventional chest images. The relative ranking in terms of decreasing ROC areas was Siemens, conventional, and Philips. Compared with conventional imaging, none of the differences in ROC curve area were statistically significant at the 5% level

  19. Data quality in diffusion tensor imaging studies of the preterm brain: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Pieterman, Kay; Plaisier, Annemarie; Dudink, Jeroen [Erasmus Medical Center - Sophia, Division of Neonatology, Department of Pediatrics, dr. Molewaterplein 60, GJ, Rotterdam (Netherlands); Department of Radiology, Erasmus Medical Center, Rotterdam (Netherlands); Govaert, Paul [Erasmus Medical Center - Sophia, Division of Neonatology, Department of Pediatrics, dr. Molewaterplein 60, GJ, Rotterdam (Netherlands); Department of Pediatrics, Koningin Paola Children' s Hospital, Antwerp (Belgium); Leemans, Alexander [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Lequin, Maarten H. [Department of Radiology, Erasmus Medical Center, Rotterdam (Netherlands)

    2015-08-15

    To study early neurodevelopment in preterm infants, evaluation of brain maturation and injury is increasingly performed using diffusion tensor imaging, for which the reliability of underlying data is paramount. To review the literature to evaluate acquisition and processing methodology in diffusion tensor imaging studies of preterm infants. We searched the Embase, Medline, Web of Science and Cochrane databases for relevant papers published between 2003 and 2013. The following keywords were included in our search: prematurity, neuroimaging, brain, and diffusion tensor imaging. We found 74 diffusion tensor imaging studies in preterm infants meeting our inclusion criteria. There was wide variation in acquisition and processing methodology, and we found incomplete reporting of these settings. Nineteen studies (26%) reported the use of neonatal hardware. Data quality assessment was not reported in 13 (18%) studies. Artefacts-correction and data-exclusion was not reported in 33 (45%) and 18 (24%) studies, respectively. Tensor estimation algorithms were reported in 56 (76%) studies but were often suboptimal. Diffusion tensor imaging acquisition and processing settings are incompletely described in current literature, vary considerably, and frequently do not meet the highest standards. (orig.)

  20. Data quality in diffusion tensor imaging studies of the preterm brain: a systematic review

    International Nuclear Information System (INIS)

    Pieterman, Kay; Plaisier, Annemarie; Dudink, Jeroen; Govaert, Paul; Leemans, Alexander; Lequin, Maarten H.

    2015-01-01

    To study early neurodevelopment in preterm infants, evaluation of brain maturation and injury is increasingly performed using diffusion tensor imaging, for which the reliability of underlying data is paramount. To review the literature to evaluate acquisition and processing methodology in diffusion tensor imaging studies of preterm infants. We searched the Embase, Medline, Web of Science and Cochrane databases for relevant papers published between 2003 and 2013. The following keywords were included in our search: prematurity, neuroimaging, brain, and diffusion tensor imaging. We found 74 diffusion tensor imaging studies in preterm infants meeting our inclusion criteria. There was wide variation in acquisition and processing methodology, and we found incomplete reporting of these settings. Nineteen studies (26%) reported the use of neonatal hardware. Data quality assessment was not reported in 13 (18%) studies. Artefacts-correction and data-exclusion was not reported in 33 (45%) and 18 (24%) studies, respectively. Tensor estimation algorithms were reported in 56 (76%) studies but were often suboptimal. Diffusion tensor imaging acquisition and processing settings are incompletely described in current literature, vary considerably, and frequently do not meet the highest standards. (orig.)

  1. OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Summary of OMERACT 6 MR Imaging Module

    DEFF Research Database (Denmark)

    McQueen, F; Lassere, M; Edmonds, J

    2003-01-01

    Magnetic resonance image (MRI) scanning is a new method for imaging and quantifying joint inflammation and damage in rheumatoid arthritis (RA). Over the past 4 years, the OMERACT MR Imaging Group has been developing and testing the RA-MRI scoring system (RAMRIS) for use in RA. The OMERACT filter...

  2. Study of x-ray CCD image sensor and application

    Science.gov (United States)

    Wang, Shuyun; Li, Tianze

    2008-12-01

    In this paper, we expounded the composing, specialty, parameter, its working process, key techniques and methods for charge coupled devices (CCD) twice value treatment. Disposal process for CCD video signal quantification was expatiated; X-ray image intensifier's constitutes, function of constitutes, coupling technique of X-ray image intensifier and CCD were analyzed. We analyzed two effective methods to reduce the harm to human beings when X-ray was used in the medical image. One was to reduce X-ray's radiation and adopt to intensify the image penetrated by X-ray to gain the same effect. The other was to use the image sensor to transfer the images to the safe area for observation. On this base, a new method was presented that CCD image sensor and X-ray image intensifier were combined organically. A practical medical X-ray photo electricity system was designed which can be used in the records and time of the human's penetrating images. The system was mainly made up with the medical X-ray, X-ray image intensifier, CCD vidicon with high resolution, image processor, display and so on. Its characteristics are: change the invisible X-ray into the visible light image; output the vivid images; short image recording time etc. At the same time we analyzed the main aspects which affect the system's resolution. Medical photo electricity system using X-ray image sensor can reduce the X-ray harm to human sharply when it is used in the medical diagnoses. At last we analyzed and looked forward the system's application in medical engineering and the related fields.

  3. The effect of image quality, repeated study, and assessment method on anatomy learning.

    Science.gov (United States)

    Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A; Wainman, Bruce C

    2017-06-01

    The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality images of the human hand and human eye. On day 0, participants learned about each anatomical specimen from paper booklets using either low-quality or high-quality images, and then completed a comprehension test using either 2D images or three-dimensional (3D) cadaveric specimens. On day 1, participants relearned each booklet, and on day 2 participants completed a final comprehension test using either 2D images or 3D cadaveric specimens. The effect of image quality on learning varied according to anatomical content, with high-quality images having a greater effect on improving learning of hand anatomy than eye anatomy (high-quality vs. low-quality for hand anatomy P = 0.018; high-quality vs. low-quality for eye anatomy P = 0.247). Also, the benefit of high-quality images on hand anatomy learning was restricted to performance on short-answer (SA) questions immediately after learning (high-quality vs. low-quality on SA questions P = 0.018), but did not apply to performance on multiple-choice (MC) questions (high-quality vs. low-quality on MC questions P = 0.109) or after participants had an additional learning opportunity (24 hours later) with anatomy content (high vs. low on SA questions P = 0.643). This study underscores the limited impact of image quality on anatomy learning, and questions whether investment in enhancing image quality of learning aids significantly promotes knowledge development. Anat Sci Educ 10: 249-261. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  4. Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging

    International Nuclear Information System (INIS)

    Yu Jianming; Lei Ziqiao; Kong Xiangchuang

    2006-01-01

    Objective: To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods: 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results: Among the total of 200 patients, there are 50 cases of rib calcification, 7 cases of rib destruction, 22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion: DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm. (authors)

  5. A comparative study of three-dimensional reconstructive images of temporomandibular joint using computed tomogram

    International Nuclear Information System (INIS)

    Lim, Suk Young; Koh, Kwang Joon

    1993-01-01

    The purpose of this study was to clarify the spatial relationship of temporomandibular joint and to an aid in the diagnosis of temporomandibular disorder. For this study, three-dimensional images of normal temporomandibular joint were reconstructed by computer image analysis system and three-dimensional reconstructive program integrated in computed tomography. The obtained results were as follows : 1. Two-dimensional computed tomograms had the better resolution than three dimensional computed tomograms in the evaluation of bone structure and the disk of TMJ. 2. Direct sagittal computed tomograms and coronal computed tomograms had the better resolution in the evaluation of the disk of TMJ. 3. The positional relationship of the disk could be visualized, but the configuration of the disk could not be clearly visualized on three-dimensional reconstructive CT images. 4. Three-dimensional reconstructive CT images had the smoother margin than three-dimensional images reconstructed by computer image analysis system, but the images of the latter had the better perspective. 5. Three-dimensional reconstructive images had the better spatial relationship of the TMJ articulation, and the joint space were more clearly visualized on dissection images.

  6. Classified study and clinical value of the phase imaging features

    International Nuclear Information System (INIS)

    Dang Yaping; Ma Aiqun; Zheng Xiaopu; Yang Aimin; Xiao Jiang; Gao Xinyao

    2000-01-01

    445 patients with various heart diseases were examined by the gated cardiac blood pool imaging, and the phase was classified. The relationship between the seven types with left ventricular function index, clinical heart function, different heart diseases as well as electrocardiograph was studied. The results showed that the phase image classification could match with the clinical heart function. It can visually, directly and accurately indicate clinical heart function and can be used to identify diagnosis of heart disease

  7. Use of volume-rendered images in registration of nuclear medicine studies

    International Nuclear Information System (INIS)

    Wallis, J.W.; Miller, T.R.; Hsu, S.S.

    1995-01-01

    A simple operator-guided alignment technique based on volume-rendered images was developed to register tomographic nuclear medicine studies. For each of 2 three-dimensional data sets to be registered, volume-rendered images were generated in 3 orthogonal projections (x,y,z) using the method of maximum-activity projection. Registration was achieved as follows: (a) One of the rendering orientations (e.g. x) was chosen for manipulation; (b) The two dimensional rendering was translated and rotated under operator control to achieve the best alignment as determined by visual assessment; (c) This rotation and translation was then applied to the underlying three-dimensional data set, with updating of the rendered images in each of the orthogonal projections; (d) Another orientation was chosen, and the process repeated. Since manipulation was performed on the small two-dimensional rendered image, feedback was instantaneous. To aid in the visual alignment, difference images and flicker images (toggling between the two data sets) were displayed. Accuracy was assessed by analysis of separate clinical data sets acquired without patient movement. After arbitrary rotation and translation of one of the two data sets, the 2 data sets were registered. Mean registration error was 0.36 pixels, corresponding to a 2.44 mm registration error. Thus, accurate registration can be achieved in under 10 minutes using this simple technique. The accuracy of registration was assessed with use of duplicate SPECT studies originating from separate reconstructions of the data from each of the detectors of a triple-head gamma camera

  8. The Physics and Applications of High Brightness Beams: Working Group C Summary on Applications to FELS

    International Nuclear Information System (INIS)

    Nuhn, Heinz-Dieter

    2003-01-01

    This is the summary of the activities in working group C, ''Application to FELs,'' which was based in the Bithia room at the Joint ICFA Advanced Accelerator and Beam Dynamics Workshop on July 1-6, 2002 in Chia Laguna, Sardinia, Italy. Working group C was small in relation to the other working groups at that workshop. Attendees include Enrica Chiadroni, University of Rome ape with an identical pulse length. ''La Sapienza'', Luca Giannessi, ENEA, Steve Lidia, LBNL, Vladimir Litvinenko, Duke University, Patrick Muggli, UCLA, Alex Murokh, UCLA, Heinz-Dieter Nuhn, SLAC, Sven Reiche, UCLA, Jamie Rosenzweig, UCLA, Claudio Pellegrini, UCLA, Susan Smith, Daresbury Laboratory, Matthew Thompson, UCLA, Alexander Varfolomeev, Russian Research Center, plus a small number of occasional visitors. The working group addressed a total of nine topics. Each topic was introduced by a presentation, which initiated a discussion of the topic during and after the presentation. The speaker of the introductory presentation facilitated the discussion. There were six topics that were treated in stand-alone sessions of working group C. In addition, there were two joint sessions, one with working group B, which included one topic, and one with working group C, which included two topics. The presentations that were given in the joint sessions are summarized in the working group summary reports for groups B and D, respectively. This summary will only discuss the topics that were addressed in the stand-alone sessions, including Start-To-End Simulations, SASE Experiment, PERSEO, ''Optics Free'' FEL Oscillators, and VISA II

  9. Deep brain two-photon NIR fluorescence imaging for study of Alzheimer's disease

    Science.gov (United States)

    Chen, Congping; Liang, Zhuoyi; Zhou, Biao; Ip, Nancy Y.; Qu, Jianan Y.

    2018-02-01

    Amyloid depositions in the brain represent the characteristic hallmarks of Alzheimer's disease (AD) pathology. The abnormal accumulation of extracellular amyloid-beta (Aβ) and resulting toxic amyloid plaques are considered to be responsible for the clinical deficits including cognitive decline and memory loss. In vivo two-photon fluorescence imaging of amyloid plaques in live AD mouse model through a chronic imaging window (thinned skull or craniotomy) provides a mean to greatly facilitate the study of the pathological mechanism of AD owing to its high spatial resolution and long-term continuous monitoring. However, the imaging depth for amyloid plaques is largely limited to upper cortical layers due to the short-wavelength fluorescence emission of commonly used amyloid probes. In this work, we reported that CRANAD-3, a near-infrared (NIR) probe for amyloid species with excitation wavelength at 900 nm and emission wavelength around 650 nm, has great advantages over conventionally used probes and is well suited for twophoton deep imaging of amyloid plaques in AD mouse brain. Compared with a commonly used MeO-X04 probe, the imaging depth of CRANAD-3 is largely extended for open skull cranial window. Furthermore, by using two-photon excited fluorescence spectroscopic imaging, we characterized the intrinsic fluorescence of the "aging pigment" lipofuscin in vivo, which has distinct spectra from CRANAD-3 labeled plaques. This study reveals the unique potential of NIR probes for in vivo, high-resolution and deep imaging of brain amyloid in Alzheimer's disease.

  10. Apoptosis imaging studies in various animal models using radio-iodinated peptide.

    Science.gov (United States)

    Kwak, Wonjung; Ha, Yeong Su; Soni, Nisarg; Lee, Woonghee; Park, Se-Il; Ahn, Heesu; An, Gwang Il; Kim, In-San; Lee, Byung-Heon; Yoo, Jeongsoo

    2015-01-01

    Apoptosis has a role in many medical disorders and treatments; hence, its non-invasive evaluation is one of the most riveting research topics. Currently annexin V is used as gold standard for imaging apoptosis. However, several drawbacks, including high background, slow body clearance, make it a suboptimum marker for apoptosis imaging. In this study, we radiolabeled the recently identified histone H1 targeting peptide (ApoPep-1) and evaluated its potential as a new apoptosis imaging agent in various animal models. ApoPep-1 (CQRPPR) was synthesized, and an extra tyrosine residue was added to its N-terminal end for radiolabeling. This peptide was radiolabeled with (124)I and (131)I and was tested for its serum stability. Surgery- and drug-induced apoptotic rat models were prepared for apoptosis evaluation, and PET imaging was performed. Doxorubicin was used for xenograft tumor treatment in mice, and the induced apoptosis was studied. Tumor metabolism and proliferation were assessed by [(18)F]FDG and [(18)F]FLT PET imaging and compared with ApoPep-1 after doxorubicin treatment. The peptide was radiolabeled at high purity, and it showed reasonably good stability in serum. Cell death was easily imaged by radiolabeled ApoPep-1 in an ischemia surgery model. And, liver apoptosis was more clearly identified by ApoPep-1 rather than [(124)I]annexin V in cycloheximide-treated models. Three doxorubicin doses inhibited tumor growth, which was evaluated by 30-40% decreases of [(18)F]FDG and [(18)F]FLT PET uptake in the tumor area. However, ApoPep-1 demonstrated more than 200% increase in tumor uptake after chemotherapy, while annexin V did not show any meaningful uptake in the tumor compared with the background. Biodistribution data were also in good agreement with the microPET imaging results. All of the experimental data clearly demonstrated high potential of the radiolabeled ApoPep-1 for in vivo apoptosis imaging.

  11. Self-instructional "virtual pathology" laboratories using web-based technology enhance medical school teaching of pathology.

    Science.gov (United States)

    Marchevsky, Alberto M; Relan, Anju; Baillie, Susan

    2003-05-01

    Second-year medical students have traditionally been taught pulmonary pathophysiology at the University of California-Los Angeles (UCLA) School of Medicine using lectures, discussion groups, and laboratory sessions. Since 1998, the laboratory sessions have been replaced by 4 interactive, self-instructional sessions using web-based technology and case-based instruction. This article addresses nature of transformation that occurred from within the course in response to the infusion of new technologies. The vast majority of the course content has been digitized and incorporated into the website of the Pathophysiology of Disease course. The teaching histological slides have been photographed digitally and organized into "cases" with clinical information, digital images and text, and audio descriptions. The students study the materials from these cases at their own pace in 2 "virtual pathology" laboratory, with a few instructors supervising the on-site sessions. The students discuss additional cases available on the website in 2 other laboratory sessions supervised by a pulmonologist and a pathologist. Marked improvement in student participation and satisfaction was seen with the use of web-based instruction. Attendance at laboratory sessions, where the students had previously been required to bring their own microscopes to study histological slides at their own pace, increased from approximately 30% to 40% of the class in previous years to almost 100%. Satisfaction surveys showed progressive improvement over the past 4 years, as various suggestions were implemented. The value of web-based instruction of pathology at the UCLA School of Medicine is discussed.

  12. Rescripting Early Memories Linked to Negative Images in Social Phobia: A Pilot Study

    Science.gov (United States)

    Wild, Jennifer; Hackmann, Ann; Clark, David M.

    2008-01-01

    Negative self-images are a maintaining factor in social phobia. A retrospective study (Hackmann, A., Clark, D.M., McManus, F. (2000). Recurrent images and early memories in social phobia. Behaviour Research and Therapy, 38, 601-610) suggested that the images may be linked to early memories of unpleasant social experiences. This preliminary study…

  13. The study for practicality of remote fire monitoring using the image

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Joon; Hwang, Sung Tai; Jeong, Kwung Chai; Jeong, Ji Young; Kim, Go Leo; Baik, Hong Kee; Baik, Moon Kee; Kim, Joo Sung; No, In Young

    1999-12-01

    1. Object; The study for practicality of remote fire monitoring system early to be able to the fire with small scaled fire in nuclear facility and commercial building. 2. Content; Examination of algorithm for artificial intelligence neural network(NN), Achieving of image preprocessing technology need to application, Production of image files of firing, Experiment of the feature extraction from images, Construction of experimental equipment and software for discrimination of the fire, Experiment of functionality of software for fire monitoring, Learning of neural network with the image and testing of discrimination of the fire. 3. Results; The technology of feature extraction of event related with neural network, discrimination of event generation, and enhancement to be discriminated the fire with learning of neural network was established. The present ability of discrimination of the fire that the reliability was about 99 percent as error of discrimination being about 0.0098 in case of learning, but it is difficult to discriminate because of various kinds of background images. Later it will be required the working for reducing the error of discrimination of the fire, with non-fire images. (author)

  14. RETAIL STORE IMAGE: A COMPARISON AMONG THEORETICAL AND EMPIRICAL DIMENSIONS IN A BRAZILIAN STUDY

    Directory of Open Access Journals (Sweden)

    Janaina de Moura Engracia Giraldi

    2008-01-01

    Full Text Available The retail store can be the key success factor, the competitive advantage of a retail company. An important element to the retail strategy is the store image; the total sum of customers’ perceptions about a store. The present paper compares the theoretical and empirical dimensions of retail store’s image in a Brazilian study. The type of research used was the quantitative study, and the data collected was analyzed by use of the factor analysis technique, in order to identify the underlying factors to retail store image. In conclusion, it was observed that the form by which the respondents evaluate the image of a specific supermarket in Brazil is simpler than what was foreseen by theory, with nine factors representing the following store image dimensions: quality,price, after sales service, advertising, clientele, assortment, convenience, atmosphere and services. An important practical contribution of the present study refers to the development of a simpler scale, that can be used by retailers in a viable form to obtain data on their perceived image.

  15. Comparative study of low-energy neutral atom imaging techniques

    International Nuclear Information System (INIS)

    Funsten, H.O.; McComas, D.J.; Scime, E.E.

    1994-01-01

    Low-energy neutral atom (LENA) imaging promise to be a revolutionary tool for global imaging of space plasmas. The technical challenges of LENA detection include separating them from the intense ambient UV without losing information about their incident trajectories, quantifying their trajectories, and obtaining high-sensitivity measurements. Two techniques that have been proposed for this purpose are based on fundamentally different atomic interaction mechanisms between LENAs and a solid; LENA transmission through an ultra thin foil and LENA reflection from a solid surface. Both of these methods provide LENA ionization (for subsequent removal from the UV by electrostatic deflection) and secondary electron emission (for time-of-flight start pulse generation and/or coincidence). They present a comparative study of the transmission and reflection techniques based on differences in atomic interactions with solids and surfaces. Transmission methods are shown to be superior for secondary electron emission rather than reflection methods. Furthermore, transmission methods are shown to be a sufficient for LENA imaging at LENA energies of approximately 1 keV to greater than 30 keV. A hybrid instrument using reflection from a low work function surface for LENA ionization and transmission for secondary electron emission is optimal for imaging of LENAs with energies less than approximately 1 keV

  16. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Matsunobu, Y; Shiotsuki, K [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka (Japan); Morishita, J [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, JP (Japan)

    2015-06-15

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

  17. SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

    International Nuclear Information System (INIS)

    Matsunobu, Y; Shiotsuki, K; Morishita, J

    2015-01-01

    Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body

  18. The content of social media's shared images about Ebola: a retrospective study.

    Science.gov (United States)

    Seltzer, E K; Jean, N S; Kramer-Golinkoff, E; Asch, D A; Merchant, R M

    2015-09-01

    Social media have strongly influenced awareness and perceptions of public health emergencies, but a considerable amount of social media content is now carried through images, rather than just text. This study's objective is to explore how image-sharing platforms are used for information dissemination in public health emergencies. Retrospective review of images posted on two popular image-sharing platforms to characterize public discourse about Ebola. Using the keyword '#ebola' we identified a 1% sample of images posted on Instagram and Flickr across two sequential weeks in November 2014. Images from both platforms were independently coded by two reviewers and characterized by themes. We reviewed 1217 images posted on Instagram and Flickr and identified themes. Nine distinct themes were identified. These included: images of health care workers and professionals [308 (25%)], West Africa [75 (6%)], the Ebola virus [59 (5%)], and artistic renderings of Ebola [64 (5%)]. Also identified were images with accompanying embedded text related to Ebola and associated: facts [68 (6%)], fears [40 (3%)], politics [46 (4%)], and jokes [284 (23%)]. Several [273 (22%)] images were unrelated to Ebola or its sequelae. Instagram images were primarily coded as jokes [255 (42%)] or unrelated [219 (36%)], while Flickr images primarily depicted health care workers and other professionals [281 (46%)] providing care or other services for prevention or treatment. Image sharing platforms are being used for information exchange about public health crises, like Ebola. Use differs by platform and discerning these differences can help inform future uses for health care professionals and researchers seeking to assess public fears and misinformation or provide targeted education/awareness interventions. Copyright © 2015 The Royal Institute of Public Health. All rights reserved.

  19. Femtosecond photodissociation dynamics of I studied by ion imaging

    DEFF Research Database (Denmark)

    Larsen, J.J.; Bjerre, N.; Mørkbak, N.J.

    1998-01-01

    on imaging is employed to analyze the fragments from timed Coulomb explosion studies of femtosecond (fs) molecular dynamics. The technique provides high detection efficiency and direct recording of the two-dimensional velocity of all ionized fragments. We illustrate the approach by studying...... agreement with quantum mechanical wave packet simulations. We discuss the perspectives for extending the studies to photochemical reactions of small polyatomic molecules...

  20. Dose-image quality study in digital chest radiography using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.; Yoriyaz, H.

    2008-01-01

    One of the main preoccupations of diagnostic radiology is to guarantee a good image-sparing dose to the patient. In the present study, Monte Carlo simulations, with MCNPX code, coupled with an adult voxel female model (FAX) were performed to investigate how image quality and dose in digital chest radiography vary with tube voltage (80-150 kV) using air-gap technique and a computed radiography system. Calculated quantities were normalized to a fixed value of entrance skin exposure (ESE) of 0.0136 R. The results of the present analysis show that the image quality for chest radiography with imaging plate is improved and the dose reduced at lower tube voltage

  1. Feasibility study of 3-T MR imaging of the skin

    Energy Technology Data Exchange (ETDEWEB)

    Aubry, Sebastien; Kastler, Bruno [CHU Jean Minjoz, Service de Radiologie A, Besancon Cedex (France); Universite de Franche-comte, Laboratoire Intervention, Imagerie, Ingenierie et Innovation en Sante, Besancon (France); Casile, Celine; Jehl, Jerome [CHU Jean Minjoz, Service de Radiologie A, Besancon Cedex (France); Humbert, Philippe [CHU Saint-Jacques, Service de Dermatologie, Besancon (France); Vidal, Chrystelle [CHU Saint-Jacques, Centre d' Investigation Clinique en Innovation technologique, Besancon (France)

    2009-07-15

    The purpose of this study was to assess the quality of 3-T magnetic resonance (MR) imaging of the skin, to describe skin anatomy at 3 T and to discuss future prospects of skin MRI. A 7-cm single-element surface receiver coil was developed for our 3-T MRI system. Thin sections were obtained with a three-dimensional FIESTA acquisition sequence and a spin-echo T1-weighted sequence (SET1). Prospective analysis was performed twice by two radiologists independently. Thirty-six healthy volunteers were included and underwent MRI on the face and the calf. Image quality was assessed regarding visibility of skin layers and quantification of artefacts. High field strength MR enables imaging of the skin with a high spatial in-plane resolution (87-180 {mu}m), the total examination lasting 15-20 min. Image quality was excellent for the calf (mean SET1 quality = 96%) with a high intra- and interobserver correlation (SET1 kappa coefficient concerning visibility of epidermis, dermis and hypodermis {>=} 0.84). Motion artefacts resulted in a small loss of quality and reproducibility for the face. In conclusion, 3-T MR allows high spatial resolution imaging of the skin and can potentially provide an accurate noninvasive means of analysing the skin. (orig.)

  2. MR imaging follow-up studies in patients with aplastic anemia

    International Nuclear Information System (INIS)

    Tscholakoff, D.; Herold, C.; Pongracz, I.; Hinterberger, W.; Kier, P.; Chott, A.; Imhof, H.

    1988-01-01

    Eight patients with aplastic anemia underwent MR imaging of the pelvis and thoracolumbar spine before and during treatment. Bone marrow patterns on MR images were correlated with stem-cell and peripheral-blood cell counts and Prussian blue stain of bone marrow (to estimate iron overload). Before treatment, two different bone marrow patterns were observed. Three patients had diffuse, homogeneous high signal intensity throughout the bone marrow, indicating fatty replacement of hematopoietic bone marrow. Bone marrow stains were negative for iron overload. Follow-up studies in these three patients showed multiple areas of hypointense foci in the bone marrow at the time when stem cell and blood cell counts returned to normal. The remaining five patients displayed inhomogeneous signal distribution (hypointense foci on T1-weighted images) in the bone marrow on the first and following MR studies. All five patients did not respond to therapy and had multiple transfusions. Bone marrow signal intensities (correlated to a phantom) were similar in patients with recovery of hematopoietic bone marrow and patients with hemochromatosis

  3. Feasibility study of an image slicer for future space application

    Science.gov (United States)

    Calcines, A.; Ichimoto, K.

    2014-08-01

    This communication presents the feasibility study of an image slicer for future space missions, especially for the integral field unit (IFU) of the SUVIT (Solar UV-Visible-IR telescope) spectro-polarimeter on board the Japanese-led solar space mission Solar-C as a backup option. The MuSICa (Multi-Slit Image slicer based on collimator-Camera) image slicer concept, originally developed for the European Solar Telescope, has been adapted to the SUVIT requirements. The IFU will reorganizes a 2-D field of view of 10 x 10 arcsec2 into three slits of 0.18 arcsec width by 185.12 arcsec length using flat slicer mirrors of 100 μm width. The layout of MuSICa for Solar-C is telecentric and offers an optical quality limited by diffraction. The entrance for the SUVIT spectro-polarimeter is composed by the three IFU slits and one ordinal long slit to study, using high resolution spectro-polarimetry, the solar atmosphere (Photosphere and Chromosphere) within a spectral range between 520 nm (optionally 280 nm) and 1,100 nm.

  4. Collaborative Initiative in Biomedical Imaging to Study Complex Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Weili [The University of North Carolina at Chapel Hill; Fiddy, Michael A. [The University of North Carolina at Charlotte

    2012-03-31

    The work reported addressed these topics: Fluorescence imaging; Optical coherence tomography; X-ray interferometer/phase imaging system; Quantitative imaging from scattered fields, Terahertz imaging and spectroscopy; and Multiphoton and Raman microscopy.

  5. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    International Nuclear Information System (INIS)

    Belentani, Clarissa; Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald; Haghighi, Parviz

    2009-01-01

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  6. Triceps brachii tendon: anatomic-MR imaging study in cadavers with histologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Belentani, Clarissa [University of California, Department of Radiology, San Diego, CA (United States); Pastore, Daniel; Wangwinyuvirat, Mani; Dirim, Berna; Trudell, Debra J.; Resnick, Donald [University of California, Department of Radiology, San Diego, CA (United States); University of California, VA Medical Center, San Diego, CA (United States); Haghighi, Parviz [University of California, VA Medical Center, San Diego, CA (United States); University of California, Department of Histology, San Diego (United States)

    2009-02-15

    The purpose of this cadaveric study was to describe the normal MR anatomy of the triceps brachii tendon (TBT) insertion, to correlate the findings with those seen in anatomic sections and histopathologic analysis, and to review triceps tendon injuries. Twelve cadaveric elbows were used according to institution guidelines. T1-weighted spin-echo MR images were acquired in three planes. Findings on MR imaging were correlated with those derived from anatomic and histologic study. On MR images, the TBT had a bipartite appearance as it inserted on olecranon in all specimens. The insertion of the medial head was deeper than that of the long and lateral heads and was mainly muscular at its insertion, with a small amount of the tendon blending with the muscle distally, necessitating histologic analysis to determine if there was tendon blending with the muscle at the site of insertion and if the medial head inserted together with the common tendon or as a single unit. At histopathologic analysis, the three heads of the triceps tendon had a common insertion on the olecranon. The bipartite aspect of the tendon that was identified in the MR images was not seen by histologic study, indicating that there was a union of the medial and common tendons just before they inserted into bone. TBT has a bipartite appearance on MR images and inserts on olecranon as a single unit. (orig.)

  7. First-in-human pilot study of a spatial frequency domain oxygenation imaging system

    Science.gov (United States)

    Gioux, Sylvain; Mazhar, Amaan; Lee, Bernard T.; Lin, Samuel J.; Tobias, Adam M.; Cuccia, David J.; Stockdale, Alan; Oketokoun, Rafiou; Ashitate, Yoshitomo; Kelly, Edward; Weinmann, Maxwell; Durr, Nicholas J.; Moffitt, Lorissa A.; Durkin, Anthony J.; Tromberg, Bruce J.; Frangioni, John V.

    2011-08-01

    Oxygenation measurements are widely used in patient care. However, most clinically available instruments currently consist of contact probes that only provide global monitoring of the patient (e.g., pulse oximetry probes) or local monitoring of small areas (e.g., spectroscopy-based probes). Visualization of oxygenation over large areas of tissue, without a priori knowledge of the location of defects, has the potential to improve patient management in many surgical and critical care applications. In this study, we present a clinically compatible multispectral spatial frequency domain imaging (SFDI) system optimized for surgical oxygenation imaging. This system was used to image tissue oxygenation over a large area (16×12 cm) and was validated during preclinical studies by comparing results obtained with an FDA-approved clinical oxygenation probe. Skin flap, bowel, and liver vascular occlusion experiments were performed on Yorkshire pigs and demonstrated that over the course of the experiment, relative changes in oxygen saturation measured using SFDI had an accuracy within 10% of those made using the FDA-approved device. Finally, the new SFDI system was translated to the clinic in a first-in-human pilot study that imaged skin flap oxygenation during reconstructive breast surgery. Overall, this study lays the foundation for clinical translation of endogenous contrast imaging using SFDI.

  8. Feasibility, safety and image quality of cardiac FDG studies during hyperinsulinaemic-euglycaemic clamping

    International Nuclear Information System (INIS)

    Bax, Jeroen J.; Visser, Frans C.; Lingen, Arthur van; Visser, Cees A.; Poldermans, Don; Elhendy, Abdou; Boersma, Eric

    2002-01-01

    Fluorine-18 fluorodeoxyglucose (FDG) imaging for the assessment of myocardial viability has become an integral part of the diagnostic and prognostic work-up of patients with ischaemic cardiomyopathy. To ensure good image quality, in particular in patients with diabetes mellitus, hyperinsulinaemic-euglycaemic clamping has been proposed. In this study we evaluated the safety and the image quality of cardiac FDG imaging during clamping in a large group of patients, including a subgroup with diabetes mellitus. The incidence of viability (on both a segment and a patient basis) was also determined for patients with and without diabetes mellitus. The safety and image quality of cardiac FDG studies during clamping were evaluated in 131 patients, including 19 with diabetes mellitus. Image quality was assessed visually and quantitatively using heart-to-lung (H/L), heart-to-liver (H/Li) and myocardium-to-background (M/B) ratios. Blood samples were drawn at baseline and at the time of FDG injection to determine levels of glucose, free fatty acids and insulin. The metabolic circumstances were optimal for FDG imaging: high insulin levels, low free fatty acid levels and glucose levels in the normal range (levels of substrates were comparable between patients with and patients without diabetes mellitus). No serious side-effects occurred in any patient. Image quality (assessed visually) was good in all patients. The quantitative parameters of image quality (H/L, H/Li and M/B) were comparable between patients with and patients without diabetes mellitus. The incidence of viability was high: 38% of patients without and 58% of patients with diabetes mellitus had substantial viability despite contractile dysfunction. It is concluded that cardiac FDG imaging during clamping is safe and provides excellent image quality, including in patients with diabetes mellitus. The incidence of viability is high, in particular in patients with diabetes mellitus. (orig.)

  9. Establishment of frame image in dynamic function renal studies

    International Nuclear Information System (INIS)

    Guedes, Germano P.; Brunetto, Sergio Q.

    1996-01-01

    Statistical procedures applied to a set of images of renal function study are described to define a region of interest (ROI) on the kidneys's contours. The kidneys geometry is considered to adapt to the emitting area in every frames

  10. Ancient mythological images and their interpretation: an introduction to iconology, semiotics and image studies in classical art history

    OpenAIRE

    Lorenz, Katharina

    2016-01-01

    When we try to make sense of pictures, what do we gain when we use a particular method - and what might we be missing or even losing? Empirical experimentation on three types of mythological imagery - a Classical Greek pot, a frieze from Hellenistic Pergamon and a second-century CE Roman sarcophagus - enables Katharina Lorenz to demonstrate how theoretical approaches to images (specifically, iconology, semiotics, and image studies) impact the meanings we elicit from Greek and Roman art. A gui...

  11. STUDY OF IMAGE SEGMENTATION TECHNIQUES ON RETINAL IMAGES FOR HEALTH CARE MANAGEMENT WITH FAST COMPUTING

    Directory of Open Access Journals (Sweden)

    Srikanth Prabhu

    2012-02-01

    Full Text Available The role of segmentation in image processing is to separate foreground from background. In this process, the features become clearly visible when appropriate filters are applied on the image. In this paper emphasis has been laid on segmentation of biometric retinal images to filter out the vessels explicitly for evaluating the bifurcation points and features for diabetic retinopathy. Segmentation on images is performed by calculating ridges or morphology. Ridges are those areas in the images where there is sharp contrast in features. Morphology targets the features using structuring elements. Structuring elements are of different shapes like disk, line which is used for extracting features of those shapes. When segmentation was performed on retinal images problems were encountered during image pre-processing stage. Also edge detection techniques have been deployed to find out the contours of the retinal images. After the segmentation has been performed, it has been seen that artifacts of the retinal images have been minimal when ridge based segmentation technique was deployed. In the field of Health Care Management, image segmentation has an important role to play as it determines whether a person is normal or having any disease specially diabetes. During the process of segmentation, diseased features are classified as diseased one’s or artifacts. The problem comes when artifacts are classified as diseased ones. This results in misclassification which has been discussed in the analysis Section. We have achieved fast computing with better performance, in terms of speed for non-repeating features, when compared to repeating features.

  12. Nano-biotechnology for biomedical and diagnostic research

    CERN Document Server

    Zahavy, Eran; Yitzhaki, Shmuel

    2011-01-01

    The title ""Nano Biotechnology for Biomedical and Diagnostics Research"" will address research aspects related to nanomaterial in imaging and biological research, nanomaterials as a biosensing tool, DNA nanotechnology, nanomaterials for drug delivery, medicinal and therapeutic application and cytotoxicity of nanomaterials. These topics will be covered by 16 different manuscripts. Amongst the authors that will contribute to the book are major scientific leaders such as S. Weiss - UCLA, I. Willner, and G. Golomb -- HUJI, S. Esener - UCSD, E.C. Simmel - Tech. Univ. Munchen, I. Medintz -- NRL, N.

  13. A study on high NA and evanescent imaging with polarized illumination

    Science.gov (United States)

    Yang, Seung-Hune

    Simulation techniques are developed for high NA polarized microscopy with Babinet's principle, partial coherence and vector diffraction for non-periodic geometries. A mathematical model for the Babinet approach is developed and interpreted. Simulation results of the Babinet's principle approach are compared with those of Rigorous Coupled Wave Theory (RCWT) for periodic structures to investigate the accuracy of this approach and its limitations. A microscope system using a special solid immersion lens (SIL) is introduced to image Blu-Ray (BD) optical disc samples without removing the protective cover layer. Aberration caused by the cover layer is minimized with a truncated SIL. Sub-surface imaging simulation is achieved by RCWT, partial coherence, vector diffraction and Babinet's Principle. Simulated results are compared with experimental images and atomic force microscopy (AFM) measurement. A technique for obtaining native and induced using a significant amount of evanescent energy is described for a solid immersion lens (SIL) microscope. Characteristics of native and induced polarization images for different object structures and materials are studied in detail. Experiments are conducted with a NA = 1.48 at lambda = 550nm microscope. Near-field images are simulated and analyzed with an RCWT approach. Contrast curve versus object spatial frequency calculations are compared with experimental measurements. Dependencies of contrast versus source polarization angles and air gap for native and induced polarization image profiles are evaluated. By using the relationship between induced polarization and topographical structure, an induced polarization image of an alternating phase shift mask (PSM) is converted into a topographical image, which shows very good agreement with AFM measurement. Images of other material structures include a dielectric grating, chrome-on-glass grating, silicon CPU structure, BD-R and BD-ROM.

  14. AN IMAGING STUDY OF A COMPLEX SOLAR CORONAL RADIO ERUPTION

    Energy Technology Data Exchange (ETDEWEB)

    Feng, S. W.; Chen, Y.; Song, H. Q.; Wang, B.; Kong, X. L., E-mail: yaochen@sdu.edu.cn [Shandong Provincial Key Laboratory of Optical Astronomy and Solar-Terrestrial Environment, and Institute of Space Sciences, Shandong University, Weihai, Shandong 264209 (China)

    2016-08-10

    Solar coronal radio bursts are enhanced radio emission excited by energetic electrons accelerated during solar eruptions. Studying these bursts is important for investigating the origin and physical mechanism of energetic particles and further diagnosing coronal parameters. Earlier studies suffered from a lack of simultaneous high-quality imaging data of the radio burst and the eruptive structure in the inner corona. Here we present a study on a complex solar radio eruption consisting of a type II burst and three reversely drifting type III bursts, using simultaneous EUV and radio imaging data. It is found that the type II burst is closely associated with a propagating and evolving CME-driven EUV shock structure, originated initially at the northern shock flank and later transferred to the top part of the shock. This source transfer is coincident with the presence of shock decay and enhancing signatures observed at the corresponding side of the EUV front. The electron energy accelerated by the shock at the flank is estimated to be ∼0.3 c by examining the imaging data of the fast-drifting herringbone structure of the type II burst. The reverse-drifting type III sources are found to be within the ejecta and correlated with a likely reconnection event therein. The implications for further observational studies and relevant space weather forecasting techniques are discussed.

  15. LINGUISTIC FEATURES OF NATO’S MEDIA IMAGE (THE CASE STUDY OF BRITISH ONLINE PUBLICATIONS

    Directory of Open Access Journals (Sweden)

    Valuyskaya Olga Ruslanovna

    2014-12-01

    Full Text Available The paper investigates linguistic specific means of NATO's image making in online British leading newspapers. The case study involves news reports and analytical articles that represent explicit and implicit evaluation of the North Atlantic Treaty Organization. The investigation is based on the principles of the media linguistic approach and suggests the structural peculiarities of a media image that can be analyzed as a three-sided unit including positive, negative and neutral structural elements of image introduction into a media text. The NATO's image can be viewed as that of a geopolitical actor, creating its Natoland. Certain media topics are analyzed as creating positive and negative images of the NATO as a military organization. A finite list of positive and negative constituents to the Alliance's image is presented in the paper. It is assumed that the simplistic writer-reader model of interaction shapes certain elements of a media image that can be interpreted by a reader. The author distinguishes in the paper the principle constituents of an international organization in general, and the NATO in particular. Findings of the study demonstrate that the NATO's media image is interpreted by the readers as the conceptual entity of two key images: a peacemaker and a hawk that are restored on lexical and intertextual levels.

  16. Image mispositioning due to dipping TI media : a physical seismic modelling study

    Energy Technology Data Exchange (ETDEWEB)

    Isaac, J.H.; Lawton, D.C.

    1998-09-01

    Physical modelling experiments were performed to study mispositioning of targets imaged beneath a dipping anisotropic overburden. The significance of the study is that many hydrocarbon resource exploration and development plays in different tectonic settings involve dipping clastic sequences which lie above the reservoir or target zone. In many areas in the Alberta foothills, dipping panels of relatively undeformed Wapiabi shales are found in abundance, overlying deep carbonate reservoirs. These experiments demonstrated the magnitude of the image mispositioning incurred by the use of an inappropriate isotropic processing code when velocity anisotropy was present in the overburden. It was shown that the lateral shift of an imaged target beneath a 1500 m thick, 45 degree dipping anisotropic overburden is significant. Zero-offset data showed a shift in the imaged location of 320 m in the updip direction of the dipping beds, while the shift on stacked time and depth migrated multichannel data was 300 m. 2 refs., 2 figs.

  17. A quantitative experimental phantom study on MRI image uniformity.

    Science.gov (United States)

    Felemban, Doaa; Verdonschot, Rinus G; Iwamoto, Yuri; Uchiyama, Yuka; Kakimoto, Naoya; Kreiborg, Sven; Murakami, Shumei

    2018-05-02

    Our goal was to assess MR image uniformity by investigating aspects influencing said uniformity via a method laid out by the National Electrical Manufacturers Association (NEMA). Six metallic materials embedded in a glass phantom were scanned (i.e., Au, Ag, Al, Au-Ag-Pd alloy, Ti and Co-Cr alloy) as well as a reference image. Sequences included Spin Echo (SE) and gradient echo (GRE) scanned in three planes (i.e., Axial, Coronal, and Sagittal). Moreover, three surface coil types (i.e., Head and Neck or HN, Brain, and TMJ coils) and two image correction methods (i.e., Surface Coil Intensity Correction or SCIC, Phased array Uniformity Enhancement or PURE) were employed to evaluate their effectiveness on image uniformity. Image uniformity was assessed using the NEMA peak-deviation non-uniformity method. Results showed that TMJ coils elicited the least uniform image and Brain coils outperformed HN coils when metallic materials were present. Additionally, when metallic materials were present, SE outperformed GRE especially for Co-Cr (particularly in the axial plane). Furthermore, both SCIC and PURE improved image uniformity compared to uncorrected images, and SCIC slightly surpassed PURE when metallic metals were present. Lastly, Co-Cr elicited the least uniform image while other metallic materials generally showed similar patterns (i.e., no significant deviation from images without metallic metals). Overall, a quantitative understanding of the factors influencing MR image uniformity (e.g., coil type, imaging method, metal susceptibility, and post-hoc correction method) is advantageous to optimize image quality, assists clinical interpretation, and may result in improved medical and dental care.

  18. Pediatric Palliative Care: A Personal Story

    Medline Plus

    Full Text Available ... Health - Meriter 252,222 views 13:34 Teen Cancer Stories | UCLA Daltrey/Townshend Teen & Young Adult Cancer Program - Duration: 11:08. UCLA Health 268,713 ... views 5:27 The Ugly Truth of Pediatric Cancer - Duration: 5:21. KidsCancerChannel 64,186 views 5: ...

  19. Pediatric Palliative Care: A Personal Story

    Medline Plus

    Full Text Available ... Little Stars 12,587 views 10:35 Teen Cancer Stories | UCLA Daltrey/Townshend Teen & Young Adult Cancer Program - Duration: 11:08. UCLA Health 264,219 views 11:08 The Ugly Truth of Pediatric Cancer - Duration: 5:21. KidsCancerChannel 63,651 views 5: ...

  20. Studies of imaging characteristics for a slab of a lossy left-handed material

    International Nuclear Information System (INIS)

    Shen Linfang; He Sailing

    2003-01-01

    The characteristics of an imaging system formed by a slab of a lossy left-handed material (LHM) are studied. The transfer function of the LHM imaging system is written in an appropriate product form with each term having a clear physical interpretation. A tiny loss of the LHM may suppress the transmission of evanescent waves through the LHM slab and this is explained physically. An analytical expression for the resolution of the imaging system is derived. It is shown that it is impossible to make a subwavelength imaging by using a realistic LHM imaging system unless the LHM slab is much thinner than the wavelength

  1. MR imaging of alar ligament in whiplash-associated disorders: an observer study

    Energy Technology Data Exchange (ETDEWEB)

    Wilmink, J.T. [Dept. of Neuroradiology, University of Maastricht (Netherlands); Patijn, J. [Dept. of Anesthesiology, University Hospital Maastricht (Netherlands)

    2001-10-01

    Rotational CT studies have been previously used in whiplash-associated disorders (WAD) to document rotatory instability of the upper cervical spine thought to be due to alar ligamentous injury. More recently MR imaging has been employed to image such injury more directly. Our study aimed to assess the reliability and reproducibility of such MRI findings. In 12 WAD patients and six asymptomatic controls the alar ligaments were imaged in the coronal plane with an 0.5-T MRI system using a quadrature neck coil and applying a fast spin echo proton density/T2-weighted sequence P(TR/TE/ETL 2,500/18 ms/16, FOV 140 mm, matrix 200 x 256, 16 x 3 mm slices, scan time 25 min). Images were graded for symmetry of imaging plane using a 3-point scale and also for presence of ligamentous injury with a 4-point scale, by two independent observers on two separate occasions. The alar ligaments could be identified in all cases. Asymmetry of the imaging plane was found to some degree in over half of the cases. Such images were much more likely to be graded as indicating injury. Of a total of 72 assessments, clearly and probably normal grades were given in 75 %, and clearly or probably abnormal grades in 25 %. Kappa values for intra- and inter-observer agreement were moderate to very poor, however, and the grading system could not reliably distinguish between patients and controls. It was concluded that with MRI techniques presently employed, alar ligamentous damage as a causative factor in WAD has not been proven. (orig.)

  2. MR imaging of alar ligament in whiplash-associated disorders: an observer study

    International Nuclear Information System (INIS)

    Wilmink, J.T.; Patijn, J.

    2001-01-01

    Rotational CT studies have been previously used in whiplash-associated disorders (WAD) to document rotatory instability of the upper cervical spine thought to be due to alar ligamentous injury. More recently MR imaging has been employed to image such injury more directly. Our study aimed to assess the reliability and reproducibility of such MRI findings. In 12 WAD patients and six asymptomatic controls the alar ligaments were imaged in the coronal plane with an 0.5-T MRI system using a quadrature neck coil and applying a fast spin echo proton density/T2-weighted sequence P(TR/TE/ETL 2,500/18 ms/16, FOV 140 mm, matrix 200 x 256, 16 x 3 mm slices, scan time 25 min). Images were graded for symmetry of imaging plane using a 3-point scale and also for presence of ligamentous injury with a 4-point scale, by two independent observers on two separate occasions. The alar ligaments could be identified in all cases. Asymmetry of the imaging plane was found to some degree in over half of the cases. Such images were much more likely to be graded as indicating injury. Of a total of 72 assessments, clearly and probably normal grades were given in 75 %, and clearly or probably abnormal grades in 25 %. Kappa values for intra- and inter-observer agreement were moderate to very poor, however, and the grading system could not reliably distinguish between patients and controls. It was concluded that with MRI techniques presently employed, alar ligamentous damage as a causative factor in WAD has not been proven. (orig.)

  3. MR imaging of alar ligament in whiplash-associated disorders: an observer study.

    Science.gov (United States)

    Wilmink, J T; Patijn, J

    2001-10-01

    Rotational CT studies have been previously used in whiplash-associated disorders (WAD) to document rotatory instability of the upper cervical spine thought to be due to alar ligamentous injury. More recently MR imaging has been employed to image such injury more directly. Our study aimed to assess the reliability and reproducibility of such MRI findings. In 12 WAD patients and six asymptomatic controls the alar ligaments were imaged in the coronal plane with an 0.5-T MRI system using a quadrature neck coil and applying a fast spin echo proton density/T2-weighted sequence (TR/TE/ETL 2,500/18 ms/16, FOV 140 mm, matrix 200 x 256, 16 x 3 mm slices, scan time 25 min). Images were graded for symmetry of imaging plane using a 3-point scale and also for presence of ligamentous injury with a 4-point scale, by two independent observers on two separate occasions. The alar ligaments could be identified in all cases. Asymmetry of the imaging plane was found to some degree in over half of the cases. Such images were much more likely to be graded as indicating injury. Of a total of 72 assessments, clearly and probably normal grades were given in 75%, and clearly or probably abnormal grades in 25%. Kappa values for intra- and inter-observer agreement were moderate to very poor, however, and the grading system could not reliably distinguish between patients and controls. It was concluded that with MRI techniques presently employed, alar ligamentous damage as a causative factor in WAD has not been proven.

  4. Digital remote viewing system for coronary care unit

    International Nuclear Information System (INIS)

    Cho, P.S.; Tillisch, J.; Huang, H.K.

    1987-01-01

    A digital remote viewing system developed for the coronary care unit at the UCLA Medical Center has been in clinical operation since March 1, 1987. The present system consists of three 512-line monitors, VAX 11/750, Gould IP8500 image processor and a broad-band communication system. The patients' images are acquired with a computed radiography system and are transmitted to the coronary care unit, which is five floors above the radiology department. This exhibit presents the architecture and the performance characteristics of the system. Also, the second-generation system, which consists of an intelligent local work station with three 1,024-line monitors and a fast digital communication network, will be introduced

  5. Profile of extended-release oxycodone/acetaminophen for acute pain

    Directory of Open Access Journals (Sweden)

    Bekhit MH

    2015-10-01

    Full Text Available Mary Hanna Bekhit1–51David Geffen School of Medicine, 2Ronald Reagan UCLA Medical Center, 3UCLA Ambulatory Surgery Center, 4UCLA Wasserman Eye Institute, 5UCLA Martin Luther King Community Hospital, University of California Los Angeles, Los Angeles, CA, USA Abstract: This article provides a historical and pharmacological overview of a new opioid analgesic that boasts an extended-release (ER formulation designed to provide both immediate and prolonged analgesia for up to 12 hours in patients who are experiencing acute pain. This novel medication, ER oxycodone/acetaminophen, competes with current US Food and Drug Administration (FDA-approved opioid formulations available on the market in that it offers two benefits concurrently: a prolonged duration of action, and multimodal analgesia through a combination of an opioid (oxycodone with a nonopioid component. Current FDA-approved combination analgesics, such as Percocet (oxycodone/acetaminophen, are available solely in immediate-release (IR formulations. Keywords: opioid, analgesic, xartemis, acute postsurgical pain, substance abuse, acetaminophen, extended release 

  6. Radiation Exposure by Nuclear Medicine Imaging Procedures: Case Study

    International Nuclear Information System (INIS)

    Kopjar, N.; Marovic, G.; Prlic, I.; Sencar, J.; Zeljezic, D.; Ramic, S.

    2013-01-01

    Using high-resolution gamma spectrometry, we investigated the activity concentrations of thallium radioisotopes in a urine sample collected during a period of 24 h following nuclear medicine cardiac imaging. As part of a thallium stress test the subject of the study received a radiopharmaceutical preparation with 201Tl (activity 111 MBq). In order to assess whether the cardiac imaging procedure resulted in lymphocyte genome damage, we studied the frequency of sister chromatid exchanges (SCE) and lymphocyte cell kinetics in the blood samples collected before and after the cardiac imaging. The highest activity concentration (538960.9 ± 405.9 Bq/L u rine) was estimated for 201Tl, followed by 1770.54 ± 3.57 Bq/L u rine for 202Tl, and 422.035 ± 2.091 Bq/Lurine for 200Tl. The applied radiopharmaceutical contained 99.595 % of 201Tl, 0.078 % of 200Tl and 0.327 % of 202Tl. The estimated effective dose received through a single exposure to the radiopharmaceutical and calculated for a period of two days was mostly affected by 201Tl (0.0453 mSv). Due to its half-life of 12.2 days, the contribution of 202Tl (0.0008 mSv) to the effective dose was also significant. Results of the cytogenetic analysis indicate that a single diagnostic exposure to thallium caused an increase of SCE frequency and decrease of the proliferation rate index (PRI). Both parameters normalized steadily 14 days after the cardiac imaging procedure, which is also in accord with data obtained in previous studies. Our results indicate the presence of impurities in the radiopharmaceutical which should contain only 201Tl. This calls for a stricter process of quality control for radiopharmaceuticals used in nuclear medical diagnostic procedures. In this particular case, we emphasize 'contamination' with 202Tl, whose contribution to the effective dose cannot be ignored if one takes into account that it has the longest half-life of all three thallium radioisotopes detected in the urine sample.(author)

  7. Study of the inferior alveolar canal and mental foramen on digital panoramic images.

    Science.gov (United States)

    Pria, Carlos M; Masood, Farah; Beckerley, Joy M; Carson, Robert E

    2011-07-01

    To study the radiographic location of the mental foramen and appearance of the inferior alveolar canal and the relationship between image gray values and the clarity of inferior alveolar canal on the digital panoramic images and to evaluate if the histogram equalization of the digital image would improve the visualization of the inferior alveolar canal outline on the digital panoramic images in the mandible. Five hundred digital panoramic images were evaluated by two examiners using a specific inclusion criteria. Only the right side of the mandible was studied. Chi-square analyses were used for comparisons of distributions. Mean and median pixel values were analyzed separately with a one-way analysis of variance. Also, percentages were calculated to report the usefulness of the histogram equalization for visualization of canal. RESULTS show variation in location of mental foramen. Most frequent location of the mental foramen was reported as first and second premolar region. Chi-square analysis showed that the frequency of occurrence of the mental foramen was equally probable for any of the three locations. The study did not find significant usefulness of the gray values obtained from the histogram equalization in predicting the clarity of inferior alveolar canal outlines. Knowing the normal relationship and the anatomical variation of the maxillofacial structures for each patient is important for surgical implant treatment planning to avoid future complications. It is also important to be familiar with the advantages and limitations of diagnostic aids available before making treatment planning decisions based on such findings. Digital imaging, Panoramic, Inferior alveolar canal, Mental foramen. How to cite this article: Pria CM, Masood F, Beckerley JM, Carson RE. Study of the Inferior Alveolar Canal and Mental Foramen on Digital Panoramic Images. J Contemp Dent Pract 2011;12(4):265-271. Source of support: Nil Conflict of interest: None declared.

  8. Serotonin alterations in anorexia and bulimia nervosa: new insights from imaging studies.

    Science.gov (United States)

    Kaye, Walter H; Frank, Guido K; Bailer, Ursula F; Henry, Shannan E; Meltzer, Carolyn C; Price, Julie C; Mathis, Chester A; Wagner, Angela

    2005-05-19

    Anorexia nervosa (AN) and bulimia nervosa (BN) are related disorders with relatively homogenous presentations such as age of onset and gender distribution. In addition, they share symptoms, such as extremes of food consumption, body image distortion, anxiety and obsessions, and ego-syntonic neglect, raises the possibility that these symptoms reflect disturbed brain function that contributes to the pathophysiology of this illness. Recent brain imaging studies have identified altered activity in frontal, cingulate, temporal, and parietal cortical regions in AN and BN. Importantly, such disturbances are present when subjects are ill and persist after recovery, suggesting that these may be traits that are independent of the state of the illness. Emerging data point to a dysregulation of serotonin pathways in cortical and limbic structures that may be related to anxiety, behavioral inhibition, and body image distortions. In specific, recent studies using PET with serotonin specific radioligands implicate alterations of 5-HT1A and 5-HT2A receptors and the 5-HT transporter. Alterations of these circuits may affect mood and impulse control as well as the motivating and hedonic aspects of feeding behavior. Such imaging studies may offer insights into new pharmacology and psychotherapy approaches.

  9. Cinematic study of temporomandibular joint motion using ultra-fast magnetic resonance imaging.

    Science.gov (United States)

    Manière-Ezvan, A; Havet, T; Franconi, J M; Quémar, J C; de Certaines, J D

    1999-10-01

    Magnetic Resonance Images (MRI) of the temporomandibular joint (TMJ) are usually performed to study the opening/closing movements of the mandible and have up to now been pseudodynamic step-by-step images simulating condylar motion by post-processing reconstruction. The aim of this study was: 1. to optimize a TMJ cine-imaging method to give a better clinical result than the step-by-step methods; 2. to develop an ultra-fast MRI Gradient Echo (GE) sequence for this purpose; and 3. to analyze condylar movements in the sagittal, coronal and para-axial planes during border mandibular displacements and chewing. Both TM joints were studied in six asymptomatic volunteers. The method involved a compromise between in-plane resolution, slice thickness, signal-to-noise ratio and time resolution. Routine clinical use was found to be a GE pulse sequence providing three images per second with an isometric voxel resolution of approximately two millimeters in ridge. This did not allow visualization of the disk. Using this sequence enabled real and simultaneous condylar displacement observation in the three planes of space and therefore contributed to a better functional diagnosis of pathologic TMJ motions.

  10. Autoradiography study and SPECT imaging of reporter gene HSV1-tk expression in heart

    Energy Technology Data Exchange (ETDEWEB)

    Lan Xiaoli [Department of Nuclear Medicine, Union Hospital, Tongji Medical College of Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan, Hubei Province, 430022 (China)], E-mail: LXL730724@hotmail.com; Liu Ying; He Yong; Wu Tao; Zhang Binqing; Gao Zairong; An Rui [Department of Nuclear Medicine, Union Hospital, Tongji Medical College of Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan, Hubei Province, 430022 (China); Zhang Yongxue [Department of Nuclear Medicine, Union Hospital, Tongji Medical College of Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan, Hubei Province, 430022 (China)], E-mail: zhyx1229@163.com

    2010-04-15

    Aim: To demonstrate the feasibility and optimal conditions of imaging herpes simplex virus 1-thymidine kinase (HSV1-tk) gene transferred into hearts with {sup 131}I-2'-fluoro-2'-deoxy-1-{beta}-D-arabinofuranosyl-5-iodouracil ({sup 131}I-FIAU) using autoradiography (ARG) and single photon emission computed tomography (SPECT) in animal models. Methods: HSV1-tk inserted into adenovirus vector (Ad5-tk) and adenovirus (Ad5-null) was prepared. Rats or rabbits were divided into a study group receiving intramyocardial injection of Ad5-tk, and a control group receiving Ad-null injection. In the study group of rats, two sets of experiments, time-course study and dose-dependence study, were performed. In time-course experiments, rats were injected with {sup 131}I-FIAU on Days 1, 2, 3, 5 and 7, after transfection of 1x10{sup 8} pfu Ad5-tk, to study the feasibility and suitable time course for reporter gene imaging. In dose-dependence study, various titers of Ad5-tk (5x10{sup 8}, 1x10{sup 8}, 5x10{sup 7} and 1x10{sup 7} pfu) were used to determine the threshold and optimal viral titer needed for detection of gene expression. The gamma counts of hearts were measured. The rat myocardium was analyzed by ARG and reverse transcriptase-polymerase chain reaction (RT-PCR). SPECT whole-body planar imaging and cardiac tomographic imaging were performed in the rabbit models. Results: From the ARG images, rats injected with Ad5-tk showed significant {sup 131}I-FIAU activity in the anterolateral wall compared with background signals seen in the control Ad5-null rats. In time-course study, the highest radioactivity in the focal myocardium could be seen on Day 1, and then progressively declined with time. In dose-dependence study, the level of {sup 131}I-FIAU accumulation in the transfected myocardium declined with the decrease of Ad viral titers. From the ARG analysis and gamma counting, the threshold viral titer was 5x10{sup 7} pfu, and the optimal Ad titer was 1x10{sup 8} pfu

  11. Terahertz pulsed imaging study of dental caries

    Science.gov (United States)

    Karagoz, Burcu; Altan, Hakan; Kamburoglu, Kıvanç

    2015-07-01

    Current diagnostic techniques in dentistry rely predominantly on X-rays to monitor dental caries. Terahertz Pulsed Imaging (TPI) has great potential for medical applications since it is a nondestructive imaging method. It does not cause any ionization hazard on biological samples due to low energy of THz radiation. Even though it is strongly absorbed by water which exhibits very unique chemical and physical properties that contribute to strong interaction with THz radiation, teeth can still be investigated in three dimensions. Recent investigations suggest that this method can be used in the early identification of dental diseases and imperfections in the tooth structure without the hazards of using techniques which rely on x-rays. We constructed a continuous wave (CW) and time-domain reflection mode raster scan THz imaging system that enables us to investigate various teeth samples in two or three dimensions. The samples comprised of either slices of individual tooth samples or rows of teeth embedded in wax, and the imaging was done by scanning the sample across the focus of the THz beam. 2D images were generated by acquiring the intensity of the THz radiation at each pixel, while 3D images were generated by collecting the amplitude of the reflected signal at each pixel. After analyzing the measurements in both the spatial and frequency domains, the results suggest that the THz pulse is sensitive to variations in the structure of the samples that suggest that this method can be useful in detecting the presence of caries.

  12. A review of performance of near-infrared fluorescence imaging devices used in clinical studies

    Science.gov (United States)

    Zhu, B

    2015-01-01

    Near-infrared fluorescence (NIRF) molecular imaging holds great promise as a new “point-of-care” medical imaging modality that can potentially provide the sensitivity of nuclear medicine techniques, but without the radioactivity that can otherwise place limitations of usage. Recently, NIRF imaging devices of a variety of designs have emerged in the market and in investigational clinical studies using indocyanine green (ICG) as a non-targeting NIRF contrast agent to demark the blood and lymphatic vasculatures both non-invasively and intraoperatively. Approved in the USA since 1956 for intravenous administration, ICG has been more recently used off label in intradermal or subcutaneous administrations for fluorescence imaging of the lymphatic vasculature and lymph nodes. Herein, we summarize the devices of a variety of designs, summarize their performance in lymphatic imaging in a tabular format and comment on necessary efforts to develop standards for device performance to compare and use these emerging devices in future, NIRF molecular imaging studies. PMID:25410320

  13. A comparative study of image low level feature extraction algorithms

    Directory of Open Access Journals (Sweden)

    M.M. El-gayar

    2013-07-01

    Full Text Available Feature extraction and matching is at the base of many computer vision problems, such as object recognition or structure from motion. Current methods for assessing the performance of popular image matching algorithms are presented and rely on costly descriptors for detection and matching. Specifically, the method assesses the type of images under which each of the algorithms reviewed herein perform to its maximum or highest efficiency. The efficiency is measured in terms of the number of matches founds by the algorithm and the number of type I and type II errors encountered when the algorithm is tested against a specific pair of images. Current comparative studies asses the performance of the algorithms based on the results obtained in different criteria such as speed, sensitivity, occlusion, and others. This study addresses the limitations of the existing comparative tools and delivers a generalized criterion to determine beforehand the level of efficiency expected from a matching algorithm given the type of images evaluated. The algorithms and the respective images used within this work are divided into two groups: feature-based and texture-based. And from this broad classification only three of the most widely used algorithms are assessed: color histogram, FAST (Features from Accelerated Segment Test, SIFT (Scale Invariant Feature Transform, PCA-SIFT (Principal Component Analysis-SIFT, F-SIFT (fast-SIFT and SURF (speeded up robust features. The performance of the Fast-SIFT (F-SIFT feature detection methods are compared for scale changes, rotation, blur, illumination changes and affine transformations. All the experiments use repeatability measurement and the number of correct matches for the evaluation measurements. SIFT presents its stability in most situations although its slow. F-SIFT is the fastest one with good performance as the same as SURF, SIFT, PCA-SIFT show its advantages in rotation and illumination changes.

  14. An empirical study of the relationship between restaurant image and customer loyalty

    OpenAIRE

    Oh, Heung Chul

    1995-01-01

    The primary objective of this study was to empirically determine the relationship between restaurant images and loyalties toward seven competing casual dinner house restaurant chains, and to understand the nature of their competition by matching patronage behavior toward alternative restaurant chains with perceptions of alternative restaurants on particular image attributes.

  15. An exploratory study of the relationship between store image, trust ...

    African Journals Online (AJOL)

    2011-08-26

    Aug 26, 2011 ... results, this study shows that compared to corporate-owned stores, ..... 'Exploring store image, customer satisfaction and customer ... strategy: Dimensions, antecedents, and performance outcomes', Journal of Marketing,.

  16. Animal imaging studies of potential brain damage

    Science.gov (United States)

    Gatley, S. J.; Vazquez, M. E.; Rice, O.

    To date, animal studies have not been able to predict the likelihood of problems in human neurological health due to HZE particle exposure during space missions outside the Earth's magnetosphere. In ongoing studies in mice, we have demonstrated that cocaine stimulated locomotor activity is reduced by a moderate dose (120 cGy) of 1 GeV 56Fe particles. We postulate that imaging experiments in animals may provide more sensitive and earlier indicators of damage due to HZE particles than behavioral tests. Since the small size of the mouse brain is not well suited to the spatial resolution offered by microPET, we are now repeating some of our studies in a rat model. We anticipate that this will enable us to identify imaging correlates of behavioral endpoints. A specific hypothesis of our studies is that changes in the metabolic rate for glucose in striatum of animals will be correlated with alterations in locomotor activity. We will also evaluate whether the neuroprotective drug L-deprenyl reduces the effect of radiation on locomotor activity. In addition, we will conduct microPET studies of brain monoamine oxidase A and monoamine oxidase B in rats before and at various times after irradiation with HZE particles. The hypothesis is that monoamine oxidase A, which is located in nerve terminals, will be unchanged or decreased after irradiation, while monoamine oxidase B, which is located in glial cells, will be increased after irradiation. Neurochemical effects that could be measured using PET could in principle be applied in astronauts, in terms of detecting and monitoring subtle neurological damage that might have occurred during long space missions. More speculative uses of PET are in screening candidates for prolonged space missions (for example, for adequate reserve in critical brain circuits) and in optimizing medications to treat impairments after missions.

  17. Study warns of radiation risk in medical imaging

    Science.gov (United States)

    Gwynne, Peter

    2009-10-01

    A study of a million US patients suggests that some who undergo medical imaging could be exposed to more ionizing radiation than those who work with radioactive materials in nuclear power plants. The study, reported in The New England Journal of Medicine (361 849), implies that current exposure to radiation from conventional X-ray equipment as well as computed tomography (CT) and positron-emission tomography (PET) scanners could lead to tens of thousands of extra cases of cancer in the US alone.

  18. A feasibility study of magnetic resonance imaging of silicone breast implants in Finland

    DEFF Research Database (Denmark)

    Kulmala, Ilona; Boice, John D; McLaughlin, Joseph K

    2005-01-01

    to determine the feasibility of conducting a magnetic resonance imaging (MRI)-based study of rupture incidence. The pilot investigation included a clinical examination by a plastic surgeon, MRI scan, and self-administered questionnaire. The participation rate was 100%. Implants in our study represented a cross...... the other diagnosed all implants as intact. The procedures of the feasibility study proved successful, and the results demonstrate the importance of a rigid image evaluation protocol with employment of well-defined rupture criteria, as well as the benefits of several image readers.......Cosmetic breast implants have become increasingly popular throughout the world. However, there is insufficient knowledge about the frequency and severity of local complications such as rupture and capsular contracture. A pilot study of 25 Finnish women with 50 cosmetic breast implants was organized...

  19. Study of the tomographic image quality provided by a conical beam system kilo voltage

    International Nuclear Information System (INIS)

    Garayoa Roca, J.; Castro Tejero, P.

    2011-01-01

    Imaging systems play an increasingly important role in radiotherapy, and to ensure the quality of the process, you must know the characteristics and limitations of available imaging systems. In this study we sought to evaluate the image quality of an IGRT system based on a kilo voltage cone beam.

  20. Facebook and body image concern in adolescent girls: A prospective study.

    Science.gov (United States)

    Tiggemann, Marika; Slater, Amy

    2017-01-01

    The primary aim of the study was to examine the relationship across time between Facebook use and body image concern in adolescent girls. A sample of 438 girls in the first two years (Years 8 and 9) of high school (aged 13-15 years) at Time 1 completed questionnaire measures of Facebook consumption and body image concerns, and again two years later (Time 2). Facebook involvement increased substantially over the two year time period. Body image concerns also increased. Number of Facebook friends was found to prospectively predict the observed increase in drive for thinness. On the other hand, internalization and body surveillance prospectively predicted the observed increase in number of Facebook friends. It was concluded that Facebook "friendships" represent a potent sociocultural force in the body image of adolescent girls. © 2016 Wiley Periodicals, Inc. (Int J Eat Disord 2017; 50:80-83). © 2016 Wiley Periodicals, Inc.

  1. Incidental findings are frequent in young healthy individuals undergoing magnetic resonance imaging in brain research imaging studies

    DEFF Research Database (Denmark)

    Hartwigsen, Gesa; Siebner, Hartwig R; Deuschl, Günther

    2010-01-01

    There is an ongoing debate about how to handle incidental findings (IF) detected in healthy individuals who participate in research-driven magnetic resonance imaging (MRI) studies. There are currently no established guidelines regarding their management....

  2. STUDY ON BUILDING EXTRACTION FROM HIGH-RESOLUTION IMAGES USING MBI

    Directory of Open Access Journals (Sweden)

    Z. Ding

    2018-04-01

    Full Text Available Building extraction from high resolution remote sensing images is a hot research topic in the field of photogrammetry and remote sensing. However, the diversity and complexity of buildings make building extraction methods still face challenges in terms of accuracy, efficiency, and so on. In this study, a new building extraction framework based on MBI and combined with image segmentation techniques, spectral constraint, shadow constraint, and shape constraint is proposed. In order to verify the proposed method, worldview-2, GF-2, GF-1 remote sensing images covered Xiamen Software Park were used for building extraction experiments. Experimental results indicate that the proposed method improve the original MBI significantly, and the correct rate is over 86 %. Furthermore, the proposed framework reduces the false alarms by 42 % on average compared to the performance of the original MBI.

  3. Use of multispectral images and chemometrics in tomato seed studies

    DEFF Research Database (Denmark)

    Shrestha, Santosh; Deleuran, Lise Christina; Gislum, René

    During the production of tomato seeds, green tomatoes are normally discarded before seed extraction irrespective of their maturity stage. Studies indicate that seeds from green tomatoes may reach be able to reach full germination capacity. Thus the potential of multispectral imaging for non......-destructive discrimination of seeds based on their germination capacity was investigated. A total of 840 seeds extracted from green and red tomatoes were divided into two sets; a training set and a test set consisting of 648 and 192 seeds respectively. Each set consisted of 96 seeds from green tomatoes. The multispectral...... images of the seeds were captured and normalized canonical discriminant analysis was used to analyse the images. Germination tests were performed and seeds that subsequently germinated were recorded as viable. The viable seeds were classified with 99% and 98% accuracy for the training and test set...

  4. Gallium and imaging studies

    International Nuclear Information System (INIS)

    Vogel, H.C.

    1982-01-01

    The indications for the use of 67 Gallium imaging studies of the lungs are discussed. In spite of localization of 67 Ga in a large variety of neoplastic and inflammatory tissues, there is only limited application of the lung study in the differential diagnosis of pulmonary diseases. The chest radiograph will continue to be the principal tool for evaluation of pulmonary diseases. The 67 Ga-citrate scan serves as a study complementary to the chest radiograph, as it indicates the localization, extent and degree of activity of lung disease with greater accuracy than radiography. Gallium-67 scanning may be used in the evaluation of patients with lymphoreticular neoplasms, especially Hodgkin-disease and malignant lymphoma both during initial staging and in evaluation of the response to therapy. The 67 Ga-citrate scan is useful in the pre-operative evaluation of patients with lung cancer. Hilar and mediastinal lymphadenopathy are accurately revealed. The lung study is non-invasive and complementary to mediastinoscopy by showing from which glands a biopsy might be taken. Unsuspected extrathoracic secondaries may be shown up, as well as pulmonary metastases from malignancies elsewhere, although the metastases must be at least 1,5 cm in size. The 67 Ga lung scan is valuable in the evaluation of pulmonary infiltrates of suspicious infective etiology, the differentiation between pulmonary infection and pneumonia in selected cases, follow-up of sarcoid patients on corticosteroid therapy, evaluation of inflammatory activity of idiopathic pulmonary fibrosis and the early detection of neo-plastic or inflammatory diseases before the chest radiograph reveals abnormality, e.g. in diffuse carcinomatosis or Pneumocystis carinii-infection. The sensitivity of tumors to radiation or chemotherapy may be shown

  5. Experimental study of microwave-induced thermoacoustic imaging

    Science.gov (United States)

    Jacobs, Ryan T.

    Microwave-Induced Thermoacoustic Imaging (TAI) is a noninvasive hybrid modality which improves contrast by using thermoelastic wave generation induced by microwave absorption. Ultrasonography is widely used in medical practice as a low-cost alternative and supplement to magnetic resonance imaging (MRI). Although ultrasonography has relatively high image resolution (depending on the ultrasonic wavelength at diagnostic frequencies), it suffers from low image contrast of soft tissues. In this work samples are irradiated with sub-microsecond electromagnetic pulses inducing acoustic waves in the sample that are then detected with an unfocused transducer. The advantage of this hybrid modality is the ability to take advantage of the microwave absorption coefficients which provide high contrast in tissue samples. This in combination with the superior spatial resolution of ultrasound waves is important to providing a low-cost alternative to MRI and early breast cancer detection methods. This work describes the implementation of a thermoacoustic experiment using a 5 kW peak power microwave source.

  6. Evaluation of the image quality criteria and study of doses in a mammography department

    International Nuclear Information System (INIS)

    Alcantara, Marcela Costa

    2009-01-01

    The mammographic image quality criteria published by European Commission were implemented in three mammography equipment of a same radiology department in a hospital of Sao Paulo city. Among the mammography equipment, two use the screen-film system and one of them uses the indirect digital system. During the data collection, it was noted the need to conduct a study about image rejection in each mammography equipment. Therefore, this study was realized and, after that, the results in each mammography equipment of image rejection and image percentage that present each quality criterion it were compared. At the same time of this studies, it was realized other study about surface entrance dose and average glandular dose. These doses it was estimated based on different methods published by different groups of researcher, for all combinations anode filter available in the equipment. To estimate the surface entrance dose following the methodology published in Avenue's' guide and the average glandular dose following the Wu' methodology, it was developed a phantom, in different thicknesses of acrylic, to simulate a breast. Finally, the image quality it was associated with the dose received by patient. The digital equipment shows better results in the evaluation of quality criteria, lower rate of image rejection and lower values of average glandular dose and surface entrance dose in all methods studied. But it is not sufficient, because is not adequate for patients with great breast. (author)

  7. Image of Women in Advertisements: A Preliminary Study of Avenues for Change.

    Science.gov (United States)

    Butler-Paisley, Matilda, Ed.; And Others

    The Center for Research on Women (CROW) at Stanford University along with the Communication Department, the Psychology Department, and the School of Education conducted a study on the image of women in advertising and suggested ways to improve women's image in the advertising media. With the objective of sponsoring some alternatives to expedite…

  8. Patient management after noninvasive cardiac imaging results from SPARC (Study of myocardial perfusion and coronary anatomy imaging roles in coronary artery disease).

    NARCIS (Netherlands)

    Hachamovitch, R.; Nutter, B.; Hlatky, M.A.; Shaw, L.J.; Ridner, M.L.; Dorbala, S.; Beanlands, R.S.; Chow, B.J.; Branscomb, E.; Chareonthaitawee, P.; Weigold, W.G.; Voros, S.; Abbara, S.; Yasuda, T.; Jacobs, J.E.; Lesser, J.; Berman, D.S.; Thomson, L.E.; Raman, S.; Heller, G.V.; Schussheim, A.; Brunken, R.; Williams, K.A.; Farkas, S.; Delbeke, D.; Schoepf, U.J.; Reichek, N.; Rabinowitz, S.; Sigman, S.R.; Patterson, R.; Corn, C.R.; White, R.; Kazerooni, E.; Corbett, J.; Bokhari, S.; Machac, J.; Guarneri, E.; Borges-Neto, S.; Millstine, J.W.; Caldwell, J.; Arrighi, J.; Hoffmann, U.; Budoff, M.; Lima, J.; Johnson, J.R.; Johnson, B.; Gaber, M.; Williams, J.A.; Foster, C.; Hainer, J.; Carli, M.F. Di

    2012-01-01

    OBJECTIVES: This study examined short-term cardiac catheterization rates and medication changes after cardiac imaging. BACKGROUND: Noninvasive cardiac imaging is widely used in coronary artery disease, but its effects on subsequent patient management are unclear. METHODS: We assessed the 90-day

  9. Fast visible imaging and study of edge turbulence in the Aditya tokamak

    International Nuclear Information System (INIS)

    Banerjee, Santanu; Manchanda, Ranjana; Chowdhuri, Malay Bikas; Ramaiya, Nilam; Parmar, Navin; Ghosh, Joydeep; Tanna, Rakesh L.; Shukla, Braj Kishore; Sharma, Pramod K.

    2015-01-01

    Fast visible imaging is used on toroidal magnetic confinement devices for a wide variety of purposes. This includes monitoring of the plasma evolution, transient effects in the plasma and the study of edge turbulence. Two fast visible imaging systems are installed on the Aditya tokamak. One of the system is for imaging the plasma evolution with a wide angle lens covering a major portion of the vacuum vessel. The imaging fiber bundle along with the objective lens is installed inside a radial re-entrant viewport, specially designed for the purpose. Another system is intended for tangential imaging of the plasma column. During the termination phase of Aditya plasma, large filaments are seen predominantly across all types of discharges. These filaments are apparent just after the strong interaction of the plasma column with the high field side limiter surface almost at the end of the discharge. Statistical features of these filaments and their role during the termination of plasma is studied. Further, there are many interesting visual impacts of either the experiments carried out or several inherent phenomena in Aditya like the ECRH and LHCD operations, dynamics of the runaway dominated discharges and plasma equilibrium at various discharge scenarios. Such observations and the gained physical insights will be reported. (author)

  10. Retrospective study of renal images on whole bone scanning

    International Nuclear Information System (INIS)

    Yanagisawa, Munetoshi; Machida, Toyohei; Miki, Makoto; Ohishi, Yukihiko; Ueda, Masataka

    1978-01-01

    One hundred and twenty-seven cases were surveyed by sup(99m)Tc-pyrophosphate at Jikei hospital. Renal images on whole-bone scanning were observed in all cases; 75% of all renal images were normal and 25% were abnormal. Thirteen percent of these abnormal images were symmetric and 87% were asymmetric. Four of the symmetric renal images were bilaterally bad. Three of the four bilaterally bad renal images involved prostate carcinomas with general metastases and the last involved serious bilateral hydronephrosis. The reason for the high percentage of asymmetric renal images was that the materials involved many urogenital cases. Asymmetric renal images other than the urogenital cases, were recognised in 8% of all cases. This percentage is consistent with Hattner's report. Unilateral abnormal renal images involved 8 hydronephrosis cases, 2 unilateral nonfunctioning kidneys and one malrotation kidney. Among the hydronephrosis cases, serious cases gave low uptake and mild cases gave high uptake. The reason for this phenomenon was, presumably, that there were differences in renal uptake, renal excretion and renal pelvic accumulation. In nine cases, one kidney was not visualized on whole-bone scanning, 8 of them involved nephrectomy and the remainining one unilateral nonfunctioning kidney. Six cases presented locally abnormal renal images on whole-bone scanning, three of them suffered renal cell carcinomas and the rest renal solitary cyst. Eighty-eight percent of the abnormal renal images agreed with IVP findings. The renal images of whole-bone scanning faithfully reflected the original renal lesion. Two cases of renal carcinoma and renal solitary cyst recognized on whole-bone scanning are presented, to indicate the usefulness of renal images on whole-bone scanning. (auth.)

  11. Study of three-dimensional image display by systemic CT

    International Nuclear Information System (INIS)

    Fujioka, Tadao; Ebihara, Yoshiyuki; Unei, Hiroshi; Hayashi, Masao; Shinohe, Tooru; Wada, Yuji; Sakai, Takatsugu; Kashima, Kenji; Fujita, Yoshihiro

    1989-01-01

    A head phantom for CT was scanned at 2 mm intervals from the cervix to the vertex in an attempt to obtain a three-dimensional image display of bones and facial epidermis from an ordinary axial image. Clinically, three-dimensional images were formed at eye sockets and hip joints. With the three-dimensional image using the head phantom, the entire head could be displayed at any angle. Clinically, images were obtained that could not be attained by ordinary CT scanning, such as broken bones in eye sockets and stereoscopic structure at the bottom of a cranium. The three-dimensional image display is considered to be useful in clinical diagnosis. (author)

  12. Preliminary study of copper oxide nanoparticles acoustic and magnetic properties for medical imaging

    Science.gov (United States)

    Perlman, Or; Weitz, Iris S.; Azhari, Haim

    2015-03-01

    The implementation of multimodal imaging in medicine is highly beneficial as different physical properties may provide complementary information, augmented detection ability, and diagnosis verification. Nanoparticles have been recently used as contrast agents for various imaging modalities. Their significant advantage over conventional large-scale contrast agents is the ability of detection at early stages of the disease, being less prone to obstacles on their path to the target region, and possible conjunction to therapeutics. Copper ions play essential role in human health. They are used as a cofactor for multiple key enzymes involved in various fundamental biochemistry processes. Extremely small size copper oxide nanoparticles (CuO-NPs) are readily soluble in water with high colloidal stability yielding high bioavailability. The goal of this study was to examine the magnetic and acoustic characteristics of CuO-NPs in order to evaluate their potential to serve as contrast imaging agent for both MRI and ultrasound. CuO-NPs 7nm in diameter were synthesized by hot solution method. The particles were scanned using a 9.4T MRI and demonstrated a concentration dependent T1 relaxation time shortening phenomenon. In addition, it was revealed that CuO-NPs can be detected using the ultrasonic B-scan imaging. Finally, speed of sound based ultrasonic computed tomography was applied and showed that CuO-NPs can be clearly imaged. In conclusion, the preliminary results obtained, positively indicate that CuO-NPs may be imaged by both MRI and ultrasound. The results motivate additional in-vivo studies, in which the clinical utility of fused images derived from both modalities for diagnosis improvement will be studied.

  13. Study of Image Analysis Algorithms for Segmentation, Feature Extraction and Classification of Cells

    Directory of Open Access Journals (Sweden)

    Margarita Gamarra

    2017-08-01

    Full Text Available Recent advances in microcopy and improvements in image processing algorithms have allowed the development of computer-assisted analytical approaches in cell identification. Several applications could be mentioned in this field: Cellular phenotype identification, disease detection and treatment, identifying virus entry in cells and virus classification; these applications could help to complement the opinion of medical experts. Although many surveys have been presented in medical image analysis, they focus mainly in tissues and organs and none of the surveys about image cells consider an analysis following the stages in the typical image processing: Segmentation, feature extraction and classification. The goal of this study is to provide comprehensive and critical analyses about the trends in each stage of cell image processing. In this paper, we present a literature survey about cell identification using different image processing techniques.

  14. Evaluation of multiple image-based modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: A prospective study

    International Nuclear Information System (INIS)

    Mayyas, Essa; Chetty, Indrin J.; Chetvertkov, Mikhail; Wen, Ning; Neicu, Toni; Nurushev, Teamor; Ren Lei; Pradhan, Deepak; Movsas, Benjamin; Elshaikh, Mohamed A.; Lu Mei; Stricker, Hans

    2013-01-01

    Purpose: Setup errors and prostate intrafraction motion are main sources of localization uncertainty in prostate cancer radiation therapy. This study evaluates four different imaging modalities 3D ultrasound (US), kV planar images, cone-beam computed tomography (CBCT), and implanted electromagnetic transponders (Calypso/Varian) to assess inter- and intrafraction localization errors during intensity-modulated radiation therapy based treatment of prostate cancer. Methods: Twenty-seven prostate cancer patients were enrolled in a prospective IRB-approved study and treated to a total dose of 75.6 Gy (1.8 Gy/fraction). Overall, 1100 fractions were evaluated. For each fraction, treatment targets were localized using US, kV planar images, and CBCT in a sequence defined to determine setup offsets relative to the patient skin tattoos, intermodality differences, and residual errors for each patient and patient cohort. Planning margins, following van Herk's formalism, were estimated based on error distributions. Calypso-based localization was not available for the first eight patients, therefore centroid positions of implanted gold-seed markers imaged prior to and immediately following treatment were used as a motion surrogate during treatment. For the remaining 19 patients, Calypso transponders were used to assess prostate intrafraction motion. Results: The means (μ), and standard deviations (SD) of the systematic (Σ) and random errors (σ) of interfraction prostate shifts (relative to initial skin tattoo positioning), as evaluated using CBCT, kV, and US, averaged over all patients and fractions, were: [μ CBCT = (−1.2, 0.2, 1.1) mm, Σ CBCT = (3.0, 1.4, 2.4) mm, σ CBCT = (3.2, 2.2, 2.5) mm], [μ kV = (−2.9, −0.4, 0.5) mm, Σ kV = (3.4, 3.1, 2.6) mm, σ kV = (2.9, 2.0, 2.4) mm], and [μ US = (−3.6, −1.4, 0.0) mm, Σ US = (3.3, 3.5, 2.8) mm, σ US = (4.1, 3.8, 3.6) mm], in the anterior–posterior (A/P), superior–inferior (S/I), and the left–right (L

  15. Evaluation of multiple image-based modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: A prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Mayyas, Essa; Chetty, Indrin J.; Chetvertkov, Mikhail; Wen, Ning; Neicu, Toni; Nurushev, Teamor; Ren Lei; Pradhan, Deepak; Movsas, Benjamin; Elshaikh, Mohamed A. [Department of Radiation Oncology, Henry Ford Health System, 2799 West Grand Boulevard, Detroit, Michigan 48202 (United States); Lu Mei [Department of Public Health Sciences, Henry Ford Health System, 2799 West Grand Boulevard, Detroit Michigan 48202 (United States); Stricker, Hans [Department of Urology, Henry Ford Health System, 2799 West Grand Boulevard, Detroit Michigan 48202 (United States)

    2013-04-15

    Purpose: Setup errors and prostate intrafraction motion are main sources of localization uncertainty in prostate cancer radiation therapy. This study evaluates four different imaging modalities 3D ultrasound (US), kV planar images, cone-beam computed tomography (CBCT), and implanted electromagnetic transponders (Calypso/Varian) to assess inter- and intrafraction localization errors during intensity-modulated radiation therapy based treatment of prostate cancer. Methods: Twenty-seven prostate cancer patients were enrolled in a prospective IRB-approved study and treated to a total dose of 75.6 Gy (1.8 Gy/fraction). Overall, 1100 fractions were evaluated. For each fraction, treatment targets were localized using US, kV planar images, and CBCT in a sequence defined to determine setup offsets relative to the patient skin tattoos, intermodality differences, and residual errors for each patient and patient cohort. Planning margins, following van Herk's formalism, were estimated based on error distributions. Calypso-based localization was not available for the first eight patients, therefore centroid positions of implanted gold-seed markers imaged prior to and immediately following treatment were used as a motion surrogate during treatment. For the remaining 19 patients, Calypso transponders were used to assess prostate intrafraction motion. Results: The means ({mu}), and standard deviations (SD) of the systematic ({Sigma}) and random errors ({sigma}) of interfraction prostate shifts (relative to initial skin tattoo positioning), as evaluated using CBCT, kV, and US, averaged over all patients and fractions, were: [{mu}{sub CBCT}= (-1.2, 0.2, 1.1) mm, {Sigma}{sub CBCT}= (3.0, 1.4, 2.4) mm, {sigma}{sub CBCT}= (3.2, 2.2, 2.5) mm], [{mu}{sub kV}= (-2.9, -0.4, 0.5) mm, {Sigma}{sub kV}= (3.4, 3.1, 2.6) mm, {sigma}{sub kV}= (2.9, 2.0, 2.4) mm], and [{mu}{sub US}= (-3.6, -1.4, 0.0) mm, {Sigma}{sub US}= (3.3, 3.5, 2.8) mm, {sigma}{sub US}= (4.1, 3.8, 3.6) mm], in the anterior

  16. Imaging Primary Lung Cancers in Mice to Study Radiation Biology

    International Nuclear Information System (INIS)

    Kirsch, David G.; Grimm, Jan; Guimaraes, Alexander R.; Wojtkiewicz, Gregory R.; Perez, Bradford A.; Santiago, Philip M.; Anthony, Nikolas K.; Forbes, Thomas; Doppke, Karen

    2010-01-01

    Purpose: To image a genetically engineered mouse model of non-small-cell lung cancer with micro-computed tomography (micro-CT) to measure tumor response to radiation therapy. Methods and Materials: The Cre-loxP system was used to generate primary lung cancers in mice with mutation in K-ras alone or in combination with p53 mutation. Mice were serially imaged by micro-CT, and tumor volumes were determined. A comparison of tumor volume by micro-CT and tumor histology was performed. Tumor response to radiation therapy (15.5 Gy) was assessed with micro-CT. Results: The tumor volume measured with free-breathing micro-CT scans was greater than the volume calculated by histology. Nevertheless, this imaging approach demonstrated that lung cancers with mutant p53 grew more rapidly than lung tumors with wild-type p53 and also showed that radiation therapy increased the doubling time of p53 mutant lung cancers fivefold. Conclusions: Micro-CT is an effective tool to noninvasively measure the growth of primary lung cancers in genetically engineered mice and assess tumor response to radiation therapy. This imaging approach will be useful to study the radiation biology of lung cancer.

  17. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  18. Advances in imaging: impact on studying craniofacial bone structure.

    Science.gov (United States)

    Majumdar, S

    2003-01-01

    Methods for measuring the structure of craniofacial bones are discussed in this paper. In addition to the three-dimensional macro-structure of the craniofacial skeleton, there is considerable interest in imaging the bone at a microscopic resolution in order to depict the micro-architecture of the trabecular bone itself. In addition to the density of the bone, the microarchitecture reflects bone quality. An understanding of bone quality and density changes has implications for a number of craniofacial pathologies, as well as for implant design and understanding the biomechanical function and loading of the jaw. Trabecular bone micro-architecture has been recently imaged using imaging methods such as micro-computed tomography, magnetic resonance imaging, and the images have been used in finite element models to assess bone mechanical properties. In this paper, some of the recent advances in micro-computed tomography and magnetic resonance imaging are reviewed, and their potential for imaging the trabecular bone in mandibular bones is presented. Examples of in vitro and in vivo images are presented.

  19. A Study of Light Level Effect on the Accuracy of Image Processing-based Tomato Grading

    Science.gov (United States)

    Prijatna, D.; Muhaemin, M.; Wulandari, R. P.; Herwanto, T.; Saukat, M.; Sugandi, W. K.

    2018-05-01

    Image processing method has been used in non-destructive tests of agricultural products. Compared to manual method, image processing method may produce more objective and consistent results. Image capturing box installed in currently used tomato grading machine (TEP-4) is equipped with four fluorescence lamps to illuminate the processed tomatoes. Since the performance of any lamp will decrease if its service time has exceeded its lifetime, it is predicted that this will affect tomato classification. The objective of this study was to determine the minimum light levels which affect classification accuracy. This study was conducted by varying light level from minimum and maximum on tomatoes in image capturing boxes and then investigates its effects on image characteristics. Research results showed that light intensity affects two variables which are important for classification, for example, area and color of captured image. Image processing program was able to determine correctly the weight and classification of tomatoes when light level was 30 lx to 140 lx.

  20. Application of iodine-123-labeled isopropylamphetamine imaging to the study of dementia

    International Nuclear Information System (INIS)

    Sharp, P.; Gemmell, H.; Cherryman, G.; Besson, J.; Crawford, J.; Smith, F.

    1986-01-01

    Forty-seven patients diagnosed as clinically demented were imaged with 123I isopropylamphetamine (IMP). All of these patients also had a nuclear magnetic resonance (NMR) study. In those patients diagnosed as having senile dementia of the Alzheimer type a bilateral reduction in IMP uptake in the temporo-parieto-occipital region was always seen. The NMR appearances were normal in 64% of these sites. The IMP images of patients with multi-infarct dementia varied from normal to marked focal deficits. There was, however, a much closer agreement between the abnormalities seen on the IMP and NMR images. In alcoholic dementia no focal areas of reduced IMP uptake were seen, although the uptake was generally irregular. In both Korsakoff's psychosis and Huntington's chorea the IMP uptake pattern and the NMR study were normal

  1. Magnetic resonance imaging in schizophrenia: a morphometric study

    International Nuclear Information System (INIS)

    Castro, Claudio Campi de

    2001-01-01

    Thirty-three patients with chronic schizophrenia and 21 normal subjects were submitted to magnetic resonance imaging studies using a 1.5 T scanner. Axial and coronal T 2-weighted images were obtained. The volumes of the brain, intracranial, supratentorial, infratentorial and the total, ventricular and subarachnoid cerebrospinal fluid volumes were measured using semi-automated morphometric methods. The volumes of the amygdala-hippocampus complex, para hippocampal gyrus cortex, putamen, globus pallidus, temporal lobe, gray and white matter of temporal lobe were also measured. These volumes were normalized using the intracranial volume as reference. The most relevant findings observed were reduced brain volume and increased total, ventricular and subarachnoid cerebrospinal fluid volumes in patients with schizophrenia when compared to the controls. Patients with schizophrenia had also smaller amygdala-hippocampus complexes, temporal lobes and temporal lobe white matter than the controls, as well as increased putamen volumes. (author)

  2. Fusion of multimodal medical images. Application to dynamic tri dimensional study of vertebral column

    International Nuclear Information System (INIS)

    Brunie, L.

    1992-12-01

    The object of this thesis is to put in correspondence images coming from different ways. The area of application is biomedical imaging, particularly dynamic imaging in three dimensional calculations of spinal cord. The use of computers allows modeling. Then a study of validation by clinical experimentation on spinal cord proves the efficiency of the simulation

  3. Experimental study on early detection of alloxan-induced pulmonary injury by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Awai, Kazuo; Fukuda, Hiroshi; Nakamura, Susumu; Fujikawa, Koichi; Utsumi, Toshio; Kajima, Toshio; Azuma, Kazuyoshi; Ito, Katsuhide.

    1995-01-01

    We studied the early detection of alloxan-induced pulmonary injury by magnetic resonance imaging in vivo. Permeability edema was induced in ten rats by intravenous injection of alloxan at 100 mg/Kg. T1-and T2-weighted images were acquired in five rats every 30 min for 120 min after alloxan injection. Five rats served as controls. The rats were sacrificed immediately after imaging and examined microscopically. CT images were also acquired in five rats every 30 min for 120 min after alloxan injection. Five rats served as controls. The rats were sacrificed immediately after imaging, and the wet-to-dry ratio of the lung was measured. In T1-weighted images, relative signal intensity from the lung with permeability edema rose from 30 min to 120 min, and was greater than that from normal lung every time. In T2-weighted images, there was no statistically significant difference in relative signal intensity of the lung between permeability edema and the control during 120 min. In CT images, there was also no statistically significant difference in lung density between permeability edema and the control during 120 min. There was no statistically significant difference in the wet-to-dry lung ratio between edematous lung and normal lung. In histological study, mild congestion and interstitial edema were observed in edematous lung. These results suggest the potential capability of MR imaging in detecting the early phase of permeability pulmonary edema. (author)

  4. The Use of Print Materials in the Internet Age: A Comparative Study of Academic Library Circulation Patterns

    Science.gov (United States)

    Haley, Daniel Joseph

    2010-01-01

    The circulation records from 1997/98 to 2007/08 for UCLA and from 2000/01 to 2007/08 for Pasadena City College (PCC) were analyzed to examine patterns in the use of print materials during a period of increasingly available online digital information resources. The analysis included examinations of longitudinal circulation patterns broken down by…

  5. Improved image alignment method in application to X-ray images and biological images.

    Science.gov (United States)

    Wang, Ching-Wei; Chen, Hsiang-Chou

    2013-08-01

    Alignment of medical images is a vital component of a large number of applications throughout the clinical track of events; not only within clinical diagnostic settings, but prominently so in the area of planning, consummation and evaluation of surgical and radiotherapeutical procedures. However, image registration of medical images is challenging because of variations on data appearance, imaging artifacts and complex data deformation problems. Hence, the aim of this study is to develop a robust image alignment method for medical images. An improved image registration method is proposed, and the method is evaluated with two types of medical data, including biological microscopic tissue images and dental X-ray images and compared with five state-of-the-art image registration techniques. The experimental results show that the presented method consistently performs well on both types of medical images, achieving 88.44 and 88.93% averaged registration accuracies for biological tissue images and X-ray images, respectively, and outperforms the benchmark methods. Based on the Tukey's honestly significant difference test and Fisher's least square difference test tests, the presented method performs significantly better than all existing methods (P ≤ 0.001) for tissue image alignment, and for the X-ray image registration, the proposed method performs significantly better than the two benchmark b-spline approaches (P < 0.001). The software implementation of the presented method and the data used in this study are made publicly available for scientific communities to use (http://www-o.ntust.edu.tw/∼cweiwang/ImprovedImageRegistration/). cweiwang@mail.ntust.edu.tw.

  6. Imaging stress effects on memory: a review of neuroimaging studies

    NARCIS (Netherlands)

    van Stegeren, A.H.

    2009-01-01

    Objective: To review and give an overview of neuroimaging studies that look at the role of stress (hormones) on memory. Method: An overview will be given of imaging studies that looked at the role of stress (hormones) on memory. Stress is here defined as the acute provocation of the sympathetic

  7. Measurement of $\\Delta^{++}$(1232) production in hadronic Z decays

    CERN Document Server

    Abreu, P; Adye, T; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Allport, P P; Almehed, S; Alvsvaag, S J; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Anykeyev, V B; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barate, R; Bardin, Dimitri Yuri; Barker, G J; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Benvenuti, Alberto C; Berggren, M; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Blyth, S; Bocci, V; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Bosworth, S; Botner, O; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Bricman, C; Brillault, L; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Buys, A; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carrilho, P; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerrito, L; Chabaud, V; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Daum, A; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; De Boeck, H; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Djama, F; Dolbeau, J; Dönszelmann, M; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Dufour, Y; Dupont, F; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Ershaidat, N; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Ferrer, A; Filippas-Tassos, A; Firestone, A; Fischer, P A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gibbs, M; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Grosdidier, G; Gunnarsson, P; Günther, M; Guy, J; Haedinger, U; Hahn, F; Hahn, M; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Ioannou, P; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kapusta, F; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Köhne, J H; Köne, B; Kokkinias, P; Koratzinos, M; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Kramer, P H; Krammer, Manfred; Kreuter, C; Królikowski, J; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Last, I; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Lokajícek, M; Loken, J G; López, J M; López-Fernandez, A; López-Aguera, M A; Loukas, D; Lutz, P; Lyons, L; Maehlum, G; Maio, A; Malychev, V; Mandl, F; Marco, J; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Meroni, C; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Negri, P; Némécek, S; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Pindo, M; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Rückstuhl, W; Ruhlmann-Kleider, V; Ruiz, A; Rybicki, K; Rybin, A; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schneider, H; Schyns, M A E; Sciolla, G; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnova, O G; Smith, G R; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stepaniak, K; Stichelbaut, F; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chikilev, O G; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Toet, D Z; Tomaradze, A G; Tomé, B; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; Van der Velde, C; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Waldner, F; Weierstall, M; Weilhammer, Peter; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Woschnagg, K; Yip, K; Yushchenko, O P; Zach, F; Zacharatou-Jarlskog, C; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zhigunov, V P; Zimin, N I; Zito, M; Zontar, D; Zuberi, R; Zucchelli, G C; Zumerle, G

    1995-01-01

    A measurement of the \\Delta^{++}(1232) inclusive production in hadronic decays of the Z at LEP is presented, based on 1.3 million hadronic events collected~ by the DELPHI~ detector in the 1994 LEP running~ period. The DELPHI ring imaging Cherenkov counters are used for identifying hadrons. The average \\Delta^{++}(1232) multiplicity per hadronic event is 0.079 \\pm 0.015 which is more than a factor of two below the JETSET, HERWIG and UCLA model predictions. It agrees with a recently proposed universal mass dependence of particle production rates in e^{+}e^- annihilations.

  8. A phantom study of tumor contouring on PET imaging

    International Nuclear Information System (INIS)

    Chen Song; Li Xuena; Li Yaming; Yin Yafu; Li Na; Han Chunqi

    2010-01-01

    Objective: To explore an algorithm to define the threshold value for tumor contouring on 18 F-fluorodeoxyglucose (FDG) PET imaging. Methods: A National Electrical Manufacturing Association (NEMA)NU 2 1994 PET phantom with 5 spheres of different diameters were filled with 18 F-FDG. Seven different sphere-to-background ratios were obtained and the phantom was scanned by Discovery LS 4. For each sphere-to-background ratio, the maximum standardized uptake value (SUV max ) of each sphere, the SUV of the border of each sphere (SUV border ), the mean SUV of a 1 cm region of background (SUV bg ) and the diameter (D) of each sphere were measured. SPSS 13.0 software was used for curve fitting and regression analysis to obtain the threshold algorithm. The calculated thresholds were applied to delineate 29 pathologically confirmed lung cancer lesions on PET images and the obtained volumes were compared with the volumes contoured on CT images in lung window. Results: The algorithm for defining contour threshold is TH% = 33.1% + 46.8% SUV bg /SUV max + 13.9%/D (r = 0.994) by phantom studies. For 29 lung cancer lesions, the average gross tumor volumes (GTV) delineated on PET and CT are (7.36±1.62) ml and (8.31±2.05) ml, respectively (t = -1.26, P>0.05). Conclusion: The proposed threshold algorithm for tumor contouring on PET image could provide comparable GTV with CT. (authors)

  9. Vaccine Images on Twitter: Analysis of What Images are Shared

    Science.gov (United States)

    Dredze, Mark

    2018-01-01

    Background Visual imagery plays a key role in health communication; however, there is little understanding of what aspects of vaccine-related images make them effective communication aids. Twitter, a popular venue for discussions related to vaccination, provides numerous images that are shared with tweets. Objective The objectives of this study were to understand how images are used in vaccine-related tweets and provide guidance with respect to the characteristics of vaccine-related images that correlate with the higher likelihood of being retweeted. Methods We collected more than one million vaccine image messages from Twitter and characterized various properties of these images using automated image analytics. We fit a logistic regression model to predict whether or not a vaccine image tweet was retweeted, thus identifying characteristics that correlate with a higher likelihood of being shared. For comparison, we built similar models for the sharing of vaccine news on Facebook and for general image tweets. Results Most vaccine-related images are duplicates (125,916/237,478; 53.02%) or taken from other sources, not necessarily created by the author of the tweet. Almost half of the images contain embedded text, and many include images of people and syringes. The visual content is highly correlated with a tweet’s textual topics. Vaccine image tweets are twice as likely to be shared as nonimage tweets. The sentiment of an image and the objects shown in the image were the predictive factors in determining whether an image was retweeted. Conclusions We are the first to study vaccine images on Twitter. Our findings suggest future directions for the study and use of vaccine imagery and may inform communication strategies around vaccination. Furthermore, our study demonstrates an effective study methodology for image analysis. PMID:29615386

  10. Vaccine Images on Twitter: Analysis of What Images are Shared.

    Science.gov (United States)

    Chen, Tao; Dredze, Mark

    2018-04-03

    Visual imagery plays a key role in health communication; however, there is little understanding of what aspects of vaccine-related images make them effective communication aids. Twitter, a popular venue for discussions related to vaccination, provides numerous images that are shared with tweets. The objectives of this study were to understand how images are used in vaccine-related tweets and provide guidance with respect to the characteristics of vaccine-related images that correlate with the higher likelihood of being retweeted. We collected more than one million vaccine image messages from Twitter and characterized various properties of these images using automated image analytics. We fit a logistic regression model to predict whether or not a vaccine image tweet was retweeted, thus identifying characteristics that correlate with a higher likelihood of being shared. For comparison, we built similar models for the sharing of vaccine news on Facebook and for general image tweets. Most vaccine-related images are duplicates (125,916/237,478; 53.02%) or taken from other sources, not necessarily created by the author of the tweet. Almost half of the images contain embedded text, and many include images of people and syringes. The visual content is highly correlated with a tweet's textual topics. Vaccine image tweets are twice as likely to be shared as nonimage tweets. The sentiment of an image and the objects shown in the image were the predictive factors in determining whether an image was retweeted. We are the first to study vaccine images on Twitter. Our findings suggest future directions for the study and use of vaccine imagery and may inform communication strategies around vaccination. Furthermore, our study demonstrates an effective study methodology for image analysis. ©Tao Chen, Mark Dredze. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 03.04.2018.

  11. Classification of breast masses by ultrasonic Nakagami imaging: a feasibility study

    Science.gov (United States)

    Tsui, Po-Hsiang; Yeh, Chih-Kuang; Chang, Chien-Cheng; Liao, Yin-Yin

    2008-11-01

    Ultrasound is an important clinical tool in noninvasive diagnoses of breast cancer. The Nakagami statistical parameter estimated from the ultrasonic backscattered envelope has been demonstrated to be useful in complementing conventional B-mode scans when classifying breast masses. However, the shadowing effect caused by certain high-attenuation tumors in the B-mode image makes the tumor contour unclear, and thus it is more difficult to choose an appropriate region of interest from which to collect tumor data for estimating the Nakagami parameter. This study explored the feasibility of using the Nakagami parametric image to overcome the shadowing effect for visualizing the properties of breast masses. Experiments were performed on a breast-mimicking phantom and on some typical clinical cases for cysts, fat and tumors (fibroadenoma) (n = 18) in order to explore the performance of the Nakagami image under ideal and practical conditions. The experimental results showed that the Nakagami image pixels (i.e. the local Nakagami parameter) in the cyst, tumor and fat are 0.21 ± 0.01, 0.65 ± 0.05 and 0.98 ± 0.07, respectively, for six independent phantom measurements, and 0.14 ± 0.03, 0.67 ± 0.11 and 0.89 ± 0.08, respectively, for clinical experiments. This suggests that the Nakagami image is able to classify various breast masses (p < 0.005) although the clinical results from tumors of different cases have a larger variance that may be caused by the complexity of real breast tissues. In particular, unlike the B-mode image, the Nakagami image is not subject to significant shadowing effects, making it useful to complement the B-mode image to describe the tumor contour for identifying the tumor-related region when the shadowing effect is stronger or a low system gain is used.

  12. Classification of breast masses by ultrasonic Nakagami imaging: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Tsui, P-H; Chang, C-C [Division of Mechanics, Research Center for Applied Sciences, Academia Sinica, 128, Section 2, Academia Road, Nankang, Taipei 11529, Taiwan (China); Yeh, C-K; Liao, Y-Y [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan (China)], E-mail: mechang@gate.sinica.edu.tw, E-mail: ckyeh@mx.nthu.edu.tw

    2008-11-07

    Ultrasound is an important clinical tool in noninvasive diagnoses of breast cancer. The Nakagami statistical parameter estimated from the ultrasonic backscattered envelope has been demonstrated to be useful in complementing conventional B-mode scans when classifying breast masses. However, the shadowing effect caused by certain high-attenuation tumors in the B-mode image makes the tumor contour unclear, and thus it is more difficult to choose an appropriate region of interest from which to collect tumor data for estimating the Nakagami parameter. This study explored the feasibility of using the Nakagami parametric image to overcome the shadowing effect for visualizing the properties of breast masses. Experiments were performed on a breast-mimicking phantom and on some typical clinical cases for cysts, fat and tumors (fibroadenoma) (n = 18) in order to explore the performance of the Nakagami image under ideal and practical conditions. The experimental results showed that the Nakagami image pixels (i.e. the local Nakagami parameter) in the cyst, tumor and fat are 0.21 {+-} 0.01, 0.65 {+-} 0.05 and 0.98 {+-} 0.07, respectively, for six independent phantom measurements, and 0.14 {+-} 0.03, 0.67 {+-} 0.11 and 0.89 {+-} 0.08, respectively, for clinical experiments. This suggests that the Nakagami image is able to classify various breast masses (p < 0.005) although the clinical results from tumors of different cases have a larger variance that may be caused by the complexity of real breast tissues. In particular, unlike the B-mode image, the Nakagami image is not subject to significant shadowing effects, making it useful to complement the B-mode image to describe the tumor contour for identifying the tumor-related region when the shadowing effect is stronger or a low system gain is used.

  13. Comparative study of image quality and radiation dose between prospective and retrospective ECG gating technique in coronary artery imaging with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Liu Jianxin; Liu Jian; Dou Yanbin; Wang Jichen; Sun Hongyue

    2009-01-01

    Objective: To compare the image quality and radiation dose between prospective ECG-trigering and retrospective ECG gating technique in coronary artery imaging. Methods: 33 patients suspected coronary artery disease were included in this study and divided into experimental group (prospective ECG-triggering coronary artery imaging, heart rate 0.05). The mean DLP of experimental group (234.4 mGy · cm) was DLP of control group (974.4 mGy · cm) 24.1%. The mean effective dose of prospective ECG gating coronary artery imaging was 3.2 mSv. Effective dose reduced 76.47 %. Conclusions: Prospective ECG gating coronary artery imaging can obtain the similar image quality compared with prospective ECG gating coronary artery imaging but the effective dose reduced 76.47 %. Prospective ECG gating coronary artery imaging has clinical value to peoples who are able to not accept high radiation dose and with low heart rate. (authors)

  14. The Study of the Intramolecular Heavy Atom Effect in 9,10-Dichlorophenanthrene and 1,2,3,4-Tetrachloronaphthalene Using PMDR Techniques.

    Science.gov (United States)

    1978-06-30

    Inc . , 1974. 4. C. T. u n , Thesis , UCLA, 1974. 5. N. A. El-Sayed, Acta Phys. Polonica , XXXIV , 649(1968). 6. N. A. El-Sayed , Proceedings for the m...See Refs. 11 ,15 A. de Groot and 3. H. van der Waals, Physica 19, 1128 (1963). L

  15. PET IMAGING STUDIES IN DRUG ABUSE RESEARCH.

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Volkow, N.D.; Ding, Y.S.; Logan, J.; Wang, G.J.

    2001-01-29

    . This will be followed by highlights of PET studies of the acute effects of the psychostimulant drugs cocaine and methylphenidate (ritalin) and studies of the chronic effects of cocaine and of tobacco smoke on the human brain. This chapter concludes with the description of a study which uses brain imaging coupled with a specific pharmacological challenge to address the age-old question of why some people who experiment with drugs become addicted while others do not.

  16. Increase in Utilization of Afterhours Medical Imaging: A Study of Three Canadian Academic Centers.

    Science.gov (United States)

    Chaudhry, Shivani; Dhalla, Irfan; Lebovic, Gerald; Rogalla, Patrik; Dowdell, Timothy

    2015-11-01

    The objectives of our study were to assess trends in afterhours medical imaging utilization for emergency department (ED) and inpatient (IP) patient populations from 2006-2013, including analysis by modality and specialty and with adjustment for patient volume. For this retrospective study, we reviewed the number of CT, MRI, and ultrasound studies performed for the ED and IP patients during the afterhours time period (5pm - 8am on weekdays and 24 hours on weekends and statutory holidays) from 2006-2013 at three different Canadian academic hospitals. We used the Jonckheere-Terpstra (JT) test to determine statistical significance of imaging and patient volume trends. A regression model was used to examine whether there was an increasing trend over time in the volume of imaging tests per 1000 patients. For all three sites from 2006-2013 during the afterhours time period: There was a statistically significant increasing trend in total medical imaging volume, which also held true when the volumes were assessed by modality and by specialty. There was a statistically significant increasing trend in ED and IP patient volume. When medical imaging volumes were adjusted for patient volumes, there was a statistically significant increasing trend in imaging being performed per patient. Afterhours medical imaging volumes demonstrated a statistically significant increasing trend at all three sites from 2006-2013 when assessed by total volume, modality, and specialty. During the same time period and at all three sites, the ED and IP patient volumes also demonstrated a statistically significant increasing trend with more medical imaging, however, being performed per patient. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  17. Phase aided 3D imaging and modeling: dedicated systems and case studies

    Science.gov (United States)

    Yin, Yongkai; He, Dong; Liu, Zeyi; Liu, Xiaoli; Peng, Xiang

    2014-05-01

    Dedicated prototype systems for 3D imaging and modeling (3DIM) are presented. The 3D imaging systems are based on the principle of phase-aided active stereo, which have been developed in our laboratory over the past few years. The reported 3D imaging prototypes range from single 3D sensor to a kind of optical measurement network composed of multiple node 3D-sensors. To enable these 3D imaging systems, we briefly discuss the corresponding calibration techniques for both single sensor and multi-sensor optical measurement network, allowing good performance of the 3DIM prototype systems in terms of measurement accuracy and repeatability. Furthermore, two case studies including the generation of high quality color model of movable cultural heritage and photo booth from body scanning are presented to demonstrate our approach.

  18. Study of regional cerebral blood flow SPECT imaging for sudden sensorineural deafness

    International Nuclear Information System (INIS)

    Xie Changhui; Kui Xixiao; Xiong Qibin; Wen Hui; Xie Jiabiao

    1998-01-01

    Purpose: To study the clinical value of regional cerebral blood flow (rCBF) SPECT imaging for sudden sensorineural deafness (SSD). Methods: 10 normal persons, 19 conductive deafness and 31 SSD patients were examined by rCBF SPECT imaging, and compared with X CT at the same time. All SSD patients were followed up for 6∼12 months with repeated rCBF SPECT imaging. Results: 1) The radioactivity of diseased and normal horizontal temporal gyrus ratio (T/NT) in SSD patients was the lowest among three groups (P < 0.01). 2) The sensitivity (80.6%) and accurate rate (88.3%) of rCBF SPECT imaging in SSD patients were much higher than those of CT (3.2% and 50%, P < 0.01). 3) There was a significant correlation between degree of deafness and T/NT in SSD patients. 4) Good prognosis of SSD patients with normal rCBF SPECT was found. 5) The rCBF SPECT had close concordance between rCBF SPECT imaging and clinical prognosis (84.6%). Conclusions: rCBF SPECT imaging was superior to X CT in diagnosis of SSD and played an important clinical role

  19. Cell biochemistry studied by single-molecule imaging.

    Science.gov (United States)

    Mashanov, G I; Nenasheva, T A; Peckham, M; Molloy, J E

    2006-11-01

    Over the last decade, there have been remarkable developments in live-cell imaging. We can now readily observe individual protein molecules within living cells and this should contribute to a systems level understanding of biological pathways. Direct observation of single fluorophores enables several types of molecular information to be gathered. Temporal and spatial trajectories enable diffusion constants and binding kinetics to be deduced, while analyses of fluorescence lifetime, intensity, polarization or spectra give chemical and conformational information about molecules in their cellular context. By recording the spatial trajectories of pairs of interacting molecules, formation of larger molecular complexes can be studied. In the future, multicolour and multiparameter imaging of single molecules in live cells will be a powerful analytical tool for systems biology. Here, we discuss measurements of single-molecule mobility and residency at the plasma membrane of live cells. Analysis of diffusional paths at the plasma membrane gives information about its physical properties and measurement of temporal trajectories enables rates of binding and dissociation to be derived. Meanwhile, close scrutiny of individual fluorophore trajectories enables ideas about molecular dimerization and oligomerization related to function to be tested directly.

  20. Argentina: Overview of activities on Neutron Imaging (NI) and Cultural Heritage (CH) studies

    International Nuclear Information System (INIS)

    Sánchez, Fernando

    2012-01-01

    In Argentina there exists a community of researchers of national institutions involved in CH studies and also periodic congresses about the topic since 2007. A new group on neutron imaging is beginning at Bariloche Atomic Center (CNEA). The plan of this group is: - Characterize the facility: flux, doses, collimation, etc;. - Establish contact with CH researchers for offering neutron imaging; - Demonstrate capabilities of the technique with 2D imaging; - In the future, a 3D tomography improvement will be developed

  1. A Study of Visual Descriptors for Outdoor Navigation Using Google Street View Images

    OpenAIRE

    Fernández, L.; Payá, L.; Reinoso, O.; Jiménez, L. M.; Ballesta, M.

    2016-01-01

    A comparative analysis between several methods to describe outdoor panoramic images is presented. The main objective consists in studying the performance of these methods in the localization process of a mobile robot (vehicle) in an outdoor environment, when a visual map that contains images acquired from different positions of the environment is available. With this aim, we make use of the database provided by Google Street View, which contains spherical panoramic images captured in urban en...

  2. Outcomes of Patellofemoral Arthroplasty Based on Radiographic Severity.

    Science.gov (United States)

    deDeugd, Casey M; Pareek, Ayoosh; Krych, Aaron J; Cummings, Nancy M; Dahm, Diane L

    2017-04-01

    Patellofemoral arthroplasty (PFA) is increasingly performed for symptomatic patellofemoral arthritis. The purpose of this study was to evaluate the outcomes of PFA based on preoperative radiographic severity of patellofemoral arthritis. All patients who underwent PFA for isolated patellofemoral arthritis between 2002 and 2013 and had undergone preoperative magnetic resonance imaging were identified. Radiographic severity of patellofemoral arthritis was classified according to the Iwano classification system. Groups were divided between mild (grade 0-I) and moderate to severe (grade II-IV) patellofemoral arthritis. Clinical outcomes were evaluated using the Knee Society scores (KSS), University of California at Los Angeles (UCLA) and Tegner scores. Seventy-five knees in 55 patients met inclusion criteria. Mean age was 51 years (range, 36 to 81), and mean follow-up was 3 years (range, 2 to 10). All patients had grade IV patellofemoral chondromalacia and/or significant subchondral cyst formation and edema on magnetic resonance imaging. On plain radiographs, there were no patients with Iwano grade 0, 21 grade I, 15 grade II, 21 grade III, and 18 grade IV patellofemoral arthritis. There was significantly more improvement in KSS pain (P = .046), KSS function (P = .02), University of California at Los Angeles (UCLA) (P = .046) and Tegner (P = .008) scores in the Iwano grade II-IV group vs the Iwano grade I group. Patient-reported pain quality improved significantly more following PFA in the grade II-IV group (P = .04). Patients with evidence of mild patellofemoral arthritis on plain radiographs demonstrated less improvement in pain and function after PFA than those with more advanced patellofemoral arthritis. Caution should be used when considering PFA for patients with minimal radiographic evidence of patellofemoral arthritis. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. In vivo study of experimental pneumococcal meningitis using magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Østergaard Christian

    2008-01-01

    Full Text Available Abstract Background Magnetic Resonance Imaging (MRI methods were evaluated as a tool for the study of experimental meningitis. The identification and characterisation of pathophysiological parameters that vary during the course of the disease could be used as markers for future studies of new treatment strategies. Methods Rats infected intracisternally with S. pneumoniae (n = 29 or saline (n = 13 were randomized for imaging at 6, 12, 24, 30, 36, 42 or 48 hours after infection. T1W, T2W, quantitative diffusion, and post contrast T1W images were acquired at 4.7 T. Dynamic MRI (dMRI was used to evaluate blood-brain-barrier (BBB permeability and to obtain a measure of cerebral and muscle perfusion. Clinical- and motor scores, bacterial counts in CSF and blood, and WBC counts in CSF were measured. Results MR images and dMRI revealed the development of a highly significant increase in BBB permeability (P Changes in brain water distribution, assessed by ADC, and categorization of brain 'perfusion' by cortex ΔSI(bolus were subject to increased inter-rat variation as the disease progressed, but without overall differences compared to uninfected rats (P > 0.05. Areas of well-'perfused' muscle decreased with the progression of infection indicative of septicaemia (P = 0.05. Conclusion The evolution of bacterial meningitis was successfully followed in-vivo with MRI. Increasing BBB-breakdown and ventricle size was observed in rats with meningitis whereas changes in brain water distribution were heterogeneous. MRI will be a valuable technique for future studies aiming at evaluating or optimizing adjunctive treatments

  4. Quantitative imaging studies with PET VI. Project II

    International Nuclear Information System (INIS)

    Copper, M.; Chen, C.T.; Yasillo, N.; Gatley, J.; Ortega, C.; DeJesus, O.; Friedman, A.

    1985-01-01

    This project is focused upon the development of hardware and software to improve PET image analysis and upon clinical applications of PET. In this report the laboratory's progress in various attenuation correction methods for brain imaging are described. The use of time-of-flight information for image reconstruction is evaluated. The location of dopamine D1 and D2 receptors in brain was found to be largely in the basal ganghia. 1 tab. (DT)

  5. A Voxel-Based Diffusion Tensor Imaging Study of White Matter in Bipolar Disorder

    OpenAIRE

    Mahon, Katie; Wu, Jinghui; Malhotra, Anil K.; Burdick, Katherine E.; DeRosse, Pamela; Ardekani, Babak A.; Szeszko, Philip R.

    2009-01-01

    There is evidence from post-mortem and magnetic resonance imaging studies that hyperintensities, oligodendrioglial abnormalities and gross white matter volumetric alterations play a role in the pathophysiology of bipolar disorder. There is also functional imaging evidence for a defect in frontal cortico-subcortical pathways in bipolar disorder, but the white matter comprising these pathways has not been well-investigated. Few studies have investigated white matter integrity in patients with b...

  6. Primary histologic diagnosis using automated whole slide imaging: a validation study

    Directory of Open Access Journals (Sweden)

    Jukic Drazen M

    2006-04-01

    Full Text Available Abstract Background Only prototypes 5 years ago, high-speed, automated whole slide imaging (WSI systems (also called digital slide systems, virtual microscopes or wide field imagers are becoming increasingly capable and robust. Modern devices can capture a slide in 5 minutes at spatial sampling periods of less than 0.5 micron/pixel. The capacity to rapidly digitize large numbers of slides should eventually have a profound, positive impact on pathology. It is important, however, that pathologists validate these systems during development, not only to identify their limitations but to guide their evolution. Methods Three pathologists fully signed out 25 cases representing 31 parts. The laboratory information system was used to simulate real-world sign-out conditions including entering a full diagnostic field and comment (when appropriate and ordering special stains and recuts. For each case, discrepancies between diagnoses were documented by committee and a "consensus" report was formed and then compared with the microscope-based, sign-out report from the clinical archive. Results In 17 of 25 cases there were no discrepancies between the individual study pathologist reports. In 8 of the remaining cases, there were 12 discrepancies, including 3 in which image quality could be at least partially implicated. When the WSI consensus diagnoses were compared with the original sign-out diagnoses, no significant discrepancies were found. Full text of the pathologist reports, the WSI consensus diagnoses, and the original sign-out diagnoses are available as an attachment to this publication. Conclusion The results indicated that the image information contained in current whole slide images is sufficient for pathologists to make reliable diagnostic decisions and compose complex diagnostic reports. This is a very positive result; however, this does not mean that WSI is as good as a microscope. Virtually every slide had focal areas in which image quality (focus

  7. A review of molecular imaging studies reaching the clinical stage

    International Nuclear Information System (INIS)

    Wong, Franklin C.; Kim, E. Edmund

    2009-01-01

    The practice of molecular imaging in the clinics is examined across various imaging modalities to assess the current status of clinical molecular imaging. The various physiologic and scientific bases of clinical molecular imaging are surveyed to assess the possibilities and opportunities for the deployment of the different imaging modalities in the near future. The requisites for successful candidate(s) of clinical molecular imaging are reviewed for future development.

  8. EXPERIMENTAL STUDY OF FORMING A PROFESSIONAL IMAGE OF THE FUTURE PUBLIC RELATIONS SPECIALIST

    Directory of Open Access Journals (Sweden)

    Lydia Mikhailovna Semenova

    2013-11-01

    Full Text Available The article is devoted to the organization of research work on forming professional image of the future public relations specialist. The purposes of the work were to study components of students’ image, to test the concept of a professional image of the specialist, and also to process and evaluate the results. The author has presented three phases of experimental research: statement, formative and evaluative. As a result, a positive trend of forming a professional image was found. The conceptual model of forming a professional image of the future experts tested in the course of experiment has shown to be highly effective, while new methods of training (training, workshops, panel discussions, action games, etc. have substantially improved the level of development of a professional image. The results can be used in the training and retraining of specialists of higher education and people whose profession related to communications.DOI: http://dx.doi.org/10.12731/2218-7405-2013-7-48

  9. Imaging studies in chronic low back pain

    International Nuclear Information System (INIS)

    Alcalay, M.; Bourgeois, P.; Lazennec, J.Y.; Roger, B.; Dehais, J.; Dousse, V.; Laredo, J.D.; Morvan, G.; Ristori, J.M.

    1994-01-01

    Imaging brings to difficult problems in chronic low back pain incomplete data showing that it will need a lot of time to find therapeutic solutions. Some comparisons are made between tomodensitometry, nuclear magnetic imaging, the disco-scanner, these technologies allow to find small lesions but the problem is complete when it is not possible to find anything with persistent pains. 125 refs

  10. Attitude Patterns and the Production of Original Verbal Images: A Study in Construct Validity

    Science.gov (United States)

    Khatena, Joe; Torrance, E. Paul

    1971-01-01

    The Runner Studies of Attitude Patterns, a personality inventory, was used as the criterion to determine construct validity of Sounds and Images and Onomatopoeia and Images, two tests of verbal originality. (KW)

  11. Non-invasive imaging of zebrafish with spinal deformities using optical coherence tomography: a preliminary study

    Science.gov (United States)

    Bernstein, Liane; Beaudette, Kathy; Patten, Kessen; Beaulieu-Ouellet, Émilie; Strupler, Mathias; Moldovan, Florina; Boudoux, Caroline

    2013-03-01

    A zebrafish model has recently been introduced to study various genetic mutations that could lead to spinal deformities such as scoliosis. However, current imaging techniques make it difficult to perform longitudinal studies of this condition in zebrafish, especially in the early stages of development. The goal of this project is to determine whether optical coherence tomography (OCT) is a viable non-invasive method to image zebrafish exhibiting spinal deformities. Images of both live and fixed malformed zebrafish (5 to 21 days postfertilization) as well as wild-type fish (5 to 29 days postfertilization) were acquired non-invasively using a commercial SD-OCT system, with a laser source centered at 930nm (λ=100nm), permitting axial and lateral resolutions of 7 and 8μm respectively. Using two-dimensional images and three-dimensional reconstructions, it was possible to identify the malformed notochord as well as deformities in other major organs at different stages of formation. Visualization of the notochord was facilitated with the development of a segmentation algorithm. OCT images were compared to HE histological sections and images obtained by calcein staining. Because of the possibility of performing longitudinal studies on a same fish and reducing image processing time as compared with staining techniques and histology, the use of OCT could facilitate phenotypic characterization in studying genetic factors leading to spinal deformities in zebrafish and could eventually contribute to the identification of the genetic causes of spinal deformities such as scoliosis.

  12. Far infrared fusion plasma diagnostics. Task 3A, Progress report, FY 1990

    Energy Technology Data Exchange (ETDEWEB)

    Luhmann, N.C. Jr.; Peebles, W.A.

    1990-12-31

    Over the last several years, reflectometry has grown in importance as a diagnostic for both steady-state density Profiles as well as for the investigation of density fluctuations and turbulence. As a diagnostic for density profile measurement, it is generally believed to be well understood in the tokamak environment. However, its use as a fluctuation diagnostic is hampered by a lack of quantitative experimental understanding of its wavenumber sensitivity and spatial resolution. Several researchers, have theoretically investigated these questions. However, prior to the UCLA laboratory investigation, no group has experimentally investigated these questions. Because of the reflectometer`s importance to the world effort in understanding plasma turbulence and transport, UCLA has, over the last year, made its primary Task IIIA effort the resolution of these questions. UCLA has taken the lead in a quantitative experimental understanding of reflectometer data as applied to the measurement of density fluctuations. In addition to this, work has proceeded on the design, construction, and installation of a reflectometer system on UCLA`s CCT tokamak. This effort will allow a comparison between the improved confinement regimes (H-mode) observed on both the DIII-D and CCT machines with the goal of achieving a physics understanding of the phenomena. Preliminary investigation of a new diagnostic technique to measure density profiles as a function of time has been initiated at UCLA. The technique promises to be a valuable addition to the range of available plasma diagnostics. Work on advanced holographic reflectometry technique as applied to fluctuation diagnostics has awaited a better understanding of the reflectometer signal itself as discussed above. Efforts to ensure the transfer of the diagnostic developments have continued with particular attention devoted to the preliminary design of a multichannel FIR interferometer for MST.

  13. In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs

    Energy Technology Data Exchange (ETDEWEB)

    Coan, Paola [Faculty of Medicine and Institute of Clinical Radiology, Ludwig-Maximilians University, Munich (Germany); Wagner, Andreas; Mollenhauer, Juergen [Department of Orthopaedics of the University of Jena, Rudolf-Elle-Hospital Eisenberg (Germany); Bravin, Alberto; Diemoz, Paul C; Keyrilaeinen, Jani, E-mail: Paola.Coan@physik.uni-muenchen.d [European Synchrotron Radiation Facility (ESRF), Grenoble (France)

    2010-12-21

    Over the last two decades phase contrast x-ray imaging techniques have been extensively studied for applications in the biomedical field. Published results demonstrate the high capability of these imaging modalities of improving the image contrast of biological samples with respect to standard absorption-based radiography and routinely used clinical imaging techniques. A clear depiction of the anatomic structures and a more accurate disease diagnosis may be provided by using radiation doses comparable to or lower than those used in current clinical methods. In the literature many works show images of phantoms and excised biological samples proving the high sensitivity of the phase contrast imaging methods for in vitro investigations. In this scenario, the applications of the so-called analyzer-based x-ray imaging (ABI) phase contrast technique are particularly noteworthy. The objective of this work is to demonstrate the feasibility of in vivo x-ray ABI phase contrast imaging for biomedical applications and in particular with respect to joint anatomic depiction and osteoarthritis detection. ABI in planar and tomographic modes was performed in vivo on articular joints of guinea pigs in order to investigate the animals with respect to osteoarthritis by using highly monochromatic x-rays of 52 keV and a low noise detector with a pixel size of 47 x 47 {mu}m{sup 2}. Images give strong evidence of the ability of ABI in depicting both anatomic structures in complex systems as living organisms and all known signs of osteoarthritis with high contrast, high spatial resolution and with an acceptable radiation dose. This paper presents the first proof of principle study of in vivo application of ABI. The technical challenges encountered when imaging an animal in vivo are discussed. This experimental study is an important step toward the study of clinical applications of phase contrast x-ray imaging techniques.

  14. Image and Reputation of Yalova City: A Study on Yalova University Students

    Directory of Open Access Journals (Sweden)

    Cevdet Kızıl

    2015-11-01

    Full Text Available Recently, the image of a country and city has become a core competitive asset for the government and local authorities and this core competitive asset plays a critical role for domestic and foreign tourists, businessmen, residents of the city, neighbouring cities, investors, entrepreneurs and also the university students. Based on the competitive asset of city image and reputation, the perception needs an effort from a marketing perspective in order to improve the strategies for enhancing quality of life. The aim of this research is to evaluate the city image of Yalova from the eye of Yalova university students. For this purpose, image perception of students on the advantages of city, abstract image elements and residents of the city have been investiageted. The data of research have been collected through the questionnaire methodology. This study is run on 200 students as the research sample. In light of the results of the survey, the overall image perception of students about Yalova city and its residents are determined to be at medium level. Location of Yalova has a very positive perception, while intercity transportation, nature and weather conditions have a positive perception. The city is considered as peaceful, safe and clean, but expensive. Residents of Yalova are evaluated as peaceful. It is also found that, infrastructures and superstructures enhancing the Yalova city image should be improved.

  15. MR imaging of ore for heap bioleaching studies using pure phase encode acquisition methods

    Science.gov (United States)

    Fagan, Marijke A.; Sederman, Andrew J.; Johns, Michael L.

    2012-03-01

    Various MRI techniques were considered with respect to imaging of aqueous flow fields in low grade copper ore. Spin echo frequency encoded techniques were shown to produce unacceptable image distortions which led to pure phase encoded techniques being considered. Single point imaging multiple point acquisition (SPI-MPA) and spin echo single point imaging (SESPI) techniques were applied. By direct comparison with X-ray tomographic images, both techniques were found to be able to produce distortion-free images of the ore packings at 2 T. The signal to noise ratios (SNRs) of the SESPI images were found to be superior to SPI-MPA for equal total acquisition times; this was explained based on NMR relaxation measurements. SESPI was also found to produce suitable images for a range of particles sizes, whereas SPI-MPA SNR deteriorated markedly as particles size was reduced. Comparisons on a 4.7 T magnet showed significant signal loss from the SPI-MPA images, the effect of which was accentuated in the case of unsaturated flowing systems. Hence it was concluded that SESPI was the most robust imaging method for the study of copper ore heap leaching hydrology.

  16. The Study of Eating Disorders and Body Image Among Elite Martial Arts Athletes

    Directory of Open Access Journals (Sweden)

    Morteza Taheri

    2017-11-01

    Full Text Available Study objective: The competitive sports environment can enhance social and cultural pressure towards having ideal body weight in weight-sensitive sports. The close relationship between body image and performance makes the elite athletes vulnerable to eating disorders. Thus, the purpose of this research was to study eating disorders and body image among weight-class elite athletes. Methods: A cross-sectional study was carried out with elite martial arts athletes (Karate, Taekwondo, and Judo who were considered to be of higher risk for eating disorders. 63 elite martial arts male athletes (18.59 ± 5.29 yrs, and 63 non-athlete persons (17.3 ± 3.4 yrs were recruited. Body Mass Index (BMI, Waist Hip Ratio (WHR, and Percent Body Fat (PBF were measured using caliper and meter. Eating Disorder Diagnosis Scale (EDDS and Body Image Rating Scale (BIRS were used to study eating disorders and body image among elite martial arts athletes. Results: no sign of clinical EDDS were found among the investigated athletes, and non-athletes. There were significant differences in total score of EDDS (p=0.001, eating disorder and weight concern subscales (respectively p=0.012, p=0.001 in athletes and non-athletes. Furthermore, compared with the non-athlete group, elite athlete group with middle, good, and great body images scored higher on total score and all subscales of EDDS (p ≤ 0.05. Conclusion: The results from our study show the presence of worriment about eating disorder especially body weight and eating concern in elite athletes and the early detection of it may prevent progression to severe eating disorders.

  17. Theoretical and experimental study of image formation in scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Prunier epouse Mory, Claudie

    1985-01-01

    This thesis contains a theoretical and experimental study of image formation in a dedicated scanning transmission electron microscope (STEM). Using a detailed description of the different optical elements between the field emission source and the specimen, one calculates the shape and size of the primary probe of electrons impinging on the sample. This modelization enables to estimate the spatial resolution in the different imaging or microanalytical modes. The influence of the specimen and the role of the various detectors are taken into account to calculate the point spread function of the instrument in STEM imaging modes. An experimental study of the characteristic properties of phase contrast bright field micrographs and incoherent dark field ones is performed by comparison of digitally recorded images in similar conditions. Spatial resolution, contrast and signal/noise ratio are assessed by correlation methods, Fourier analysis and statistical considerations; one can deduce the optimum focusing conditions. Limits such as the point resolution on quasi-atomic metallic clusters are determined and an analysis of the capabilities of signal mixing concludes this work. Applications are offered in various domains such as the visualisation of small metallic particles, biomolecules and unstained biological sections. (author) [fr

  18. Study of TeV range cosmic ray detection with Cherenkov imaging techniques

    International Nuclear Information System (INIS)

    Ansari, R.; Gaillard, J.M.; Parrour, G.

    1992-03-01

    The Monte Carlo study of cosmic ray detection in the TeV energy range has been triggered by the authors' interest in the ARTEMIS (Antimatter Research Through the Earth Moon Ion Spectrometer) proposal. The properties of cosmic ray showers detected by Cherenkov imaging in the visible domain are studied. The detection sensitivity and the accuracy of the reconstruction of the parent particle direction using Cherenkov imaging are discussed. The backbone of the study is the atmospheric shower Monte Carlo generator developed by A.M. Hillas. A comparison between nucleon and photon induced showers of Cherenkov detection is also included. (R.P.) 14 refs., 48 figs., 3 tabs

  19. Immobilisation in Australian paediatric medical imaging: A pilot study

    International Nuclear Information System (INIS)

    Noonan, S.; Spuur, K.; Nielsen, S.

    2017-01-01

    Aims: The primary aim of this study is to document the use of paediatric immobilisation techniques in medical imaging. Secondary aims are to investigate differences between current practice of paediatric and non-paediatric facilities and radiographer gender and to investigate immobilisation protocols. Methods: A SurveyMonkey link was distributed through the Australian Society of Medical Imaging and Radiation Therapy (ASMIRT) newsletter. Radiographer members of ASMIRT were invited to participate. Frequency percentage analysis was undertaken; as the 'frequency of immobilisation' response was on a Likert scale and the ages categorical, a Fisher's exact test could determine dependency. Results: The use of paediatric immobilisation techniques was determined to be related to age. The most commonly used technique in general X-ray was “other people”; in computed tomography, Velcro, verbal reminders and distraction techniques; and in magnetic resonance imaging, sedation and Velcro. A comparison of immobilisation techniques demonstrated that Velcro use in X-ray was dependent on facility (p = 0.017) with paediatric facilities using it up to 17 years. Immobilisation frequency was dependent in 13–17 years (p = 0.035) with paediatric facilities rarely immobilising and non-paediatric facilities never. No dependencies resulted upon comparing genders. Immobilisation frequency was not dependent between protocols or current practice. Conclusion: The use of paediatric immobilisation technique is related to age with “other people”, sedation, Velcro, verbal reminders and distraction techniques being regularly used. The dependency of Velcro use and immobilisation frequency in 13–17 years is for unknown reasons and further investigation is required. A larger study should be carried out to validate these findings. - Highlights: • Document the use of paediatric immobilisation techniques in medical imaging. • Investigate differences in practice between

  20. Color image quality in projection displays: a case study

    Science.gov (United States)

    Strand, Monica; Hardeberg, Jon Y.; Nussbaum, Peter

    2005-01-01

    Recently the use of projection displays has increased dramatically in different applications such as digital cinema, home theatre, and business and educational presentations. Even if the color image quality of these devices has improved significantly over the years, it is still a common situation for users of projection displays that the projected colors differ significantly from the intended ones. This study presented in this paper attempts to analyze the color image quality of a large set of projection display devices, particularly investigating the variations in color reproduction. As a case study, a set of 14 projectors (LCD and DLP technology) at Gjovik University College have been tested under four different conditions: dark and light room, with and without using an ICC-profile. To find out more about the importance of the illumination conditions in a room, and the degree of improvement when using an ICC-profile, the results from the measurements was processed and analyzed. Eye-One Beamer from GretagMacbeth was used to make the profiles. The color image quality was evaluated both visually and by color difference calculations. The results from the analysis indicated large visual and colorimetric differences between the projectors. Our DLP projectors have generally smaller color gamut than LCD projectors. The color gamuts of older projectors are significantly smaller than that of newer ones. The amount of ambient light reaching the screen is of great importance for the visual impression. If too much reflections and other ambient light reaches the screen, the projected image gets pale and has low contrast. When using a profile, the differences in colors between the projectors gets smaller and the colors appears more correct. For one device, the average ΔE*ab color difference when compared to a relative white reference was reduced from 22 to 11, for another from 13 to 6. Blue colors have the largest variations among the projection displays and makes them

  1. Studying time of flight imaging through scattering media across multiple size scales (Conference Presentation)

    Science.gov (United States)

    Velten, Andreas

    2017-05-01

    Light scattering is a primary obstacle to optical imaging in a variety of different environments and across many size and time scales. Scattering complicates imaging on large scales when imaging through the atmosphere when imaging from airborne or space borne platforms, through marine fog, or through fog and dust in vehicle navigation, for example in self driving cars. On smaller scales, scattering is the major obstacle when imaging through human tissue in biomedical applications. Despite the large variety of participating materials and size scales, light transport in all these environments is usually described with very similar scattering models that are defined by the same small set of parameters, including scattering and absorption length and phase function. We attempt a study of scattering and methods of imaging through scattering across different scales and media, particularly with respect to the use of time of flight information. We can show that using time of flight, in addition to spatial information, provides distinct advantages in scattering environments. By performing a comparative study of scattering across scales and media, we are able to suggest scale models for scattering environments to aid lab research. We also can transfer knowledge and methodology between different fields.

  2. Strategy study of quantification harmonization of SUV in PET/CT images

    International Nuclear Information System (INIS)

    Fischer, Andreia Caroline Fischer da Silveira

    2014-01-01

    In clinical practice, PET/CT images are often analyzed qualitatively by visual comparison of tumor lesions and normal tissues uptake; and semi-quantitatively by means of a parameter called SUV (Standardized Uptake Value). To ensure that longitudinal studies acquired on different scanners are interchangeable, and information of quantification is comparable, it is necessary to establish a strategy to harmonize the quantification of SUV. The aim of this study is to evaluate the strategy to harmonize the quantification of PET/CT images, performed with different scanner models and manufacturers. For this purpose, a survey of the technical characteristics of equipment and acquisition protocols of clinical images of different services of PET/CT in the state of Rio Grande do Sul was conducted. For each scanner, the accuracy of SUV quantification, and the Recovery Coefficient (RC) curves were determined, using the reconstruction parameters clinically relevant and available. From these data, harmonized performance specifications among the evaluated scanners were identified, as well as the algorithm that produces, for each one, the most accurate quantification. Finally, the most appropriate reconstruction parameters to harmonize the SUV quantification in each scanner, either regionally or internationally were identified. It was found that the RC values of the analyzed scanners proved to be overestimated by up to 38%, particularly for objects larger than 17mm. These results demonstrate the need for further optimization, through the reconstruction parameters modification, and even the change of the reconstruction algorithm used in each scanner. It was observed that there is a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies. Thus, the choice of reconstruction method should be tied to the purpose of the PET/CT study in question, since the same reconstruction algorithm is not adequate, in one scanner, for qualitative

  3. Balance, dizziness and proprioception in patients with chronic whiplash associated disorders complaining of dizziness: A prospective randomized study comparing three exercise programs.

    Science.gov (United States)

    Treleaven, Julia; Peterson, Gunnel; Ludvigsson, Maria Landén; Kammerlind, Ann-Sofi; Peolsson, Anneli

    2016-04-01

    Dizziness and unsteadiness are common symptoms following a whiplash injury. To compare the effect of 3 exercise programs on balance, dizziness, proprioception and pain in patients with chronic whiplash complaining of dizziness. A sub-analysis of a randomized study. One hundred and forty subjects were randomized to either a physiotherapist-guided neck-specific exercise (NSE), physiotherapist-guided neck-specific exercise, with a behavioural approach (NSEB) or prescription of general physical activity (PPA) group. Pre intervention, 3, 6 and 12 months post baseline they completed the University of California Los Angeles Dizziness Questionnaire (UCLA-DQ), Visual Analogue Scales (VAS) for, dizziness at rest and during activity and physical measures (static and dynamic clinical balance tests and head repositioning accuracy (HRA)). There were significant time by group differences with respect to dizziness during activity and UCLA-Q favouring the physiotherapy led neck specific exercise group with a behavioural approach. Within group analysis of changes over time also revealed significant changes in most variables apart from static balance. Between and within group comparisons suggest that physiotherapist led neck exercise groups including a behavioural approach had advantages in improving measures of dizziness compared with the general physical activity group, although many still complained of dizziness and balance impairment. Future studies should consider exercises specifically designed to address balance, dizziness and cervical proprioception in those with persistent whiplash. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  4. Body Image and Eating Disorders among Female Students: A Pilot Nutritional Psychology Study in Ghana

    Directory of Open Access Journals (Sweden)

    Comfort Nora Ntim

    2015-04-01

    Full Text Available Body image and eating disorders have emerged as an essential facet of bio-psychosocial well-being. Although considered less prevalent in Ghana than in the West, body image and eating disorders are issues of global concern. One hundred (100 female participants with a mean age of approximately 21 years were recruited after informed consent for this pilot study. Results showed a positive correlation between body image and eating disorders. In addition, there was no significant difference between the levels of university education on female body image and eating distortions in Ghana. These findings underscore the importance for more future studies in nutritional psychology and related clinical management.

  5. High resolution in vivo bioluminescent imaging for the study of bacterial tumour targeting.

    Directory of Open Access Journals (Sweden)

    Michelle Cronin

    Full Text Available The ability to track microbes in real time in vivo is of enormous value for preclinical investigations in infectious disease or gene therapy research. Bacteria present an attractive class of vector for cancer therapy, possessing a natural ability to grow preferentially within tumours following systemic administration. Bioluminescent Imaging (BLI represents a powerful tool for use with bacteria engineered to express reporter genes such as lux. BLI is traditionally used as a 2D modality resulting in images that are limited in their ability to anatomically locate cell populations. Use of 3D diffuse optical tomography can localize the signals but still need to be combined with an anatomical imaging modality like micro-Computed Tomography (μCT for interpretation.In this study, the non-pathogenic commensal bacteria E. coli K-12 MG1655 and Bifidobacterium breve UCC2003, or Salmonella Typhimurium SL7207 each expressing the luxABCDE operon were intravenously (i.v. administered to mice bearing subcutaneous (s.c FLuc-expressing xenograft tumours. Bacterial lux signal was detected specifically in tumours of mice post i.v.-administration and bioluminescence correlated with the numbers of bacteria recovered from tissue. Through whole body imaging for both lux and FLuc, bacteria and tumour cells were co-localised. 3D BLI and μCT image analysis revealed a pattern of multiple clusters of bacteria within tumours. Investigation of spatial resolution of 3D optical imaging was supported by ex vivo histological analyses. In vivo imaging of orally-administered commensal bacteria in the gastrointestinal tract (GIT was also achieved using 3D BLI. This study demonstrates for the first time the potential to simultaneously image multiple BLI reporter genes three dimensionally in vivo using approaches that provide unique information on spatial locations.

  6. Imaging studies for failed back surgery syndrome

    International Nuclear Information System (INIS)

    Cosnard, G.; Cordoliani, Y.S.; Sarrazin, J.L.; Soulie, D.

    1995-01-01

    In patients with failed back surgery syndrome, magnetic resonance imaging (MRI) can be the best first-line imaging study because it simplifies the diagnosis. This update is based on over 600 cases. MRI shows the scar tissue at the surgical site, persistent evidence of disk herniation for several weeks after surgery, and evidence of local and regional edema in one-fourth of cases. The edema is most marked between two months and two years after the operation and can misleadingly suggest discitis. MRI is the best investigation for detecting recurrent herniation at the same vertebral level or another level. Herniated disk material is seen as a mass that does not enhance after gadolinium, in contrast to the vascularized scar tissue. Free fragments are often clearly visible within the scar tissue. Fragments that migrate to the epidural space can give rise to granulomatous reactions. Scar tissue can be seen in the epidural space and within the disk; it can show enhancement after gadolinium for several years. The scar can be atrophic or hypertrophic and can encase or impinge on the dural sac and nerve roots. Pathological fibrosis cannot be differentiated from ordinary scar tissue. Arachnoiditis causing adherence of the nerve roots to the dura mater or to each other occurs in 5 % to 10 % of cases. Nerve root enhancement after gadolinium is seen in three-fourths of cases. Bone lesions are common, especially some time after surgery; they are usually accompanied with other lesions. Hematomas are seen in less than 10 % of cases. Infections are similarly rare (0.25 % each for discitis and epiduritis). The diagnosis of discitis is difficult and requires percutaneous biopsy of the disk, especially when MRI shows fluid within the disk, with decreased signal intensity on T2 images, and non enhancement after intravenous gadolinium. (authors). 19 refs., 7 figs

  7. Should processed or raw image data be used in mammographic image quality analyses? A comparative study of three full-field digital mammography systems

    International Nuclear Information System (INIS)

    Borg, Mark; Badr, Ishmail; Royle, Gary

    2015-01-01

    The purpose of this study is to compare a number of measured image quality parameters using processed and unprocessed or raw images in two full-field direct digital units and one computed radiography mammography system. This study shows that the difference between raw and processed image data is system specific. The results have shown that there are no significant differences between raw and processed data in the mean threshold contrast values using the contrast-detail mammography phantom in all the systems investigated; however, these results cannot be generalised to all available systems. Notable differences were noted in contrast-to-noise ratios and in other tests including: response function, modulation transfer function, noise equivalent quanta, normalised noise power spectra and detective quantum efficiency as specified in IEC 62220-1-2. Consequently, the authors strongly recommend the use of raw data for all image quality analyses in digital mammography. (authors)

  8. A study on applying image dictionary to inner organ registration

    International Nuclear Information System (INIS)

    Matsuno, Takamichi; Asai, Takeshi; Iwata, Takuya; Hontani, Hidekata

    2010-01-01

    In this article, we report on selecting image features that are useful for registering organ surface in medical image based on image dictionary constructed for the organ. Here, the image dictionary denotes a basis set, which is non-orthogonal and over-complete one and is designed to represent images of the target organ. We propose a method that refers to a combination of the basis obtained for reconstructing a given image in order to estimate the location of the target organ. (author)

  9. Distorted images of one's own body activates the prefrontal cortex and limbic/paralimbic system in young women: a functional magnetic resonance imaging study.

    Science.gov (United States)

    Kurosaki, Mitsuhaya; Shirao, Naoko; Yamashita, Hidehisa; Okamoto, Yasumasa; Yamawaki, Shigeto

    2006-02-15

    Our aim was to study the gender differences in brain activation upon viewing visual stimuli of distorted images of one's own body. We performed functional magnetic resonance imaging on 11 healthy young men and 11 healthy young women using the "body image tasks" which consisted of fat, real, and thin shapes of the subject's own body. Comparison of the brain activation upon performing the fat-image task versus real-image task showed significant activation of the bilateral prefrontal cortex and left parahippocampal area including the amygdala in the women, and significant activation of the right occipital lobe including the primary and secondary visual cortices in the men. Comparison of brain activation upon performing the thin-image task versus real-image task showed significant activation of the left prefrontal cortex, left limbic area including the cingulate gyrus and paralimbic area including the insula in women, and significant activation of the occipital lobe including the left primary and secondary visual cortices in men. These results suggest that women tend to perceive distorted images of their own bodies by complex cognitive processing of emotion, whereas men tend to perceive distorted images of their own bodies by object visual processing and spatial visual processing.

  10. A high-density SNP linkage scan with 142 combined subtype ADHD sib pairs identifies linkage regions on chromosomes 9 and 16.

    Science.gov (United States)

    Asherson, P; Zhou, K; Anney, R J L; Franke, B; Buitelaar, J; Ebstein, R; Gill, M; Altink, M; Arnold, R; Boer, F; Brookes, K; Buschgens, C; Butler, L; Cambell, D; Chen, W; Christiansen, H; Feldman, L; Fleischman, K; Fliers, E; Howe-Forbes, R; Goldfarb, A; Heise, A; Gabriëls, I; Johansson, L; Lubetzki, I; Marco, R; Medad, S; Minderaa, R; Mulas, F; Müller, U; Mulligan, A; Neale, B; Rijsdijk, F; Rabin, K; Rommelse, N; Sethna, V; Sorohan, J; Uebel, H; Psychogiou, L; Weeks, A; Barrett, R; Xu, X; Banaschewski, T; Sonuga-Barke, E; Eisenberg, J; Manor, I; Miranda, A; Oades, R D; Roeyers, H; Rothenberger, A; Sergeant, J; Steinhausen, H-C; Taylor, E; Thompson, M; Faraone, S V

    2008-05-01

    As part of the International Multi-centre ADHD Genetics project we completed an affected sibling pair study of 142 narrowly defined Diagnostic and Statistical Manual of Mental Disorders, fourth edition combined type attention deficit hyperactivity disorder (ADHD) proband-sibling pairs. No linkage was observed on the most established ADHD-linked genomic regions of 5p and 17p. We found suggestive linkage signals on chromosomes 9 and 16, respectively, with the highest multipoint nonparametric linkage signal on chromosome 16q23 at 99 cM (log of the odds, LOD=3.1) overlapping data published from the previous UCLA (University of California, Los Angeles) (LOD>1, approximately 95 cM) and Dutch (LOD>1, approximately 100 cM) studies. The second highest peak in this study was on chromosome 9q22 at 90 cM (LOD=2.13); both the previous UCLA and German studies also found some evidence of linkage at almost the same location (UCLA LOD=1.45 at 93 cM; German LOD=0.68 at 100 cM). The overlap of these two main peaks with previous findings suggests that loci linked to ADHD may lie within these regions. Meta-analysis or reanalysis of the raw data of all the available ADHD linkage scan data may help to clarify whether these represent true linked loci.

  11. A study into the review and verification of breast images treated with isocentric technique

    International Nuclear Information System (INIS)

    Mitchell, Fiona

    2007-01-01

    In radiation therapy practice, portal imaging is a common occurrence. Radiation Oncologists want to be able to view the actual treatment port and compare it to the simulated view for quality assurance. Historically, this has been the domain of oncologists only but with the changes in imaging technology, this area of practice is now more commonly shared with the radiation therapists. Purpose: The primary aim of this study was to compare the Radiation Therapists' result versus the Radiation Oncologists' practice of review and verification of electronic portal imaging in the treatment of breast cancer. A secondary result was enhancement of electronic portal imaging use. Methods: The study was divided into two parts. Part 1 reviewed imaging of tangential breast treatment and part 2 reviewed mono-isocentric four-field breast technique. The review and verification of the images were conducted by the Radiation Therapists and Radiation Oncologists and their subsequent results were compared. Results: Overall the Radiation Oncologist agreed with 96.9% of the images approved by the Radiation Therapists. This makes for a rejection rate of 3.1%. In general, Radiation Therapists adhered to the guidelines more closely than the Radiation Oncologist hence the rejection rate of Radiation Therapists was greater than the Radiation Oncologist by 7.0%. Conclusions: The practice of electronic portal imaging review and verification in the treatment of breast cancer can be streamlined and achieved more efficiently. The Radiation Therapists consistently demonstrated their ability to review and verify the portal images, as equivalent to the Radiation Oncologist. Given the high standard of accuracy demonstrated the process of portal image review should be transferred to the Radiation Therapist. This transfer leads to reduction in duplicity of task, an increase in the use of technology, an improvement in efficiencies, and an increase in the quality of care, which will potentially lead to more

  12. Study of turbulent flow using Half-Fourier Echo-Planar imaging

    International Nuclear Information System (INIS)

    Rodriguez, A.O.

    2006-01-01

    The Echo-Planar Imaging technique combined with a partial Fourier acquisition method was used to obtain velocity images for liquid flows in a circular cross-section pipe at Reynolds number of up to 8000. This partial-Fourier imaging scheme is able to generate shorter echo times than the full-Fourier Echo-Planar Imaging methods, reducing the signal attenuation due to T2 * and flow. Velocity images along the z axis were acquired with a time-scale of 80 ms thus obtaining a real-time description of flow in both the laminar and turbulent regimes. Velocity values and velocity fluctuations were computed with the flow image data. A comparison plot of NMR velocity and bulk velocity and a plot of velocity fluctuations were calculated to investigate the feasibility of this imaging technique. Flow encoded Echo-Planar Imaging together with a reduced data acquisition method can provide us with a real-time technique to capture instantaneous images of the flow field for both laminar and turbulent regimes. (author)

  13. Evaluation of fibrinogen-DTPA-99mTc. Biodistribution and imaging studies

    International Nuclear Information System (INIS)

    Lungu, V.; Mihailescu, G.; Fugaru, V.; Preda, A.

    1998-01-01

    Labelling with 99m Tc of fibrinogen, using DTPA anhydride as the bifunctional chelating agent, was studied in animals with venous thrombi. The parameters studied were: i) coupled reaction of 99m Tc with the fibrinogen-DTPA-Sn(II) in lyophilised form; ii) biodistribution studies of fibrinogen- 99m Tc in animals with venous thrombi, and iii) imaging studies by scintigraphic methods. The present study showed that the radiochemical purity of fibrinogen-DTPA- 99m Tc is > 95% for a maximum of 5 mCi (185 MBq) radioactivity of 99m Tc in the 1.5-2 ml volume. Above this level of radioactivity we found a drastic decrease in the radiochemical purity. The radioactivity ratio of the venous thrombi to the blood was 2.32+-0.45. The scintigraphic images showed a significant accumulation of fibrinogen-DTPA- 99m Tc in 1-hour-old thrombi, 1 hour after injection. From this results the diagnostic potential of fibrinogen-DTPA-Sn(II) in kit form was evaluated. (author)

  14. Magnetic Resonance Imaging Study Using True versus Sham Acupuncture

    Directory of Open Access Journals (Sweden)

    Chunxiao Wu

    2014-01-01

    Full Text Available Functional magnetic resonance imaging (fMRI has been shown to detect the specificity of acupuncture points, as proved by numerous studies. In this study, resting-state fMRI was used to observe brain areas activated by acupuncture at the Taichong (LR3 acupoint. A total of 15 healthy subjects received brain resting-state fMRI before acupuncture and after sham and true acupuncture, respectively, at LR3. Image data processing was performed using Data Processing Assistant for Resting-State fMRI and REST software. The combination of amplitude of low-frequency fluctuation (ALFF and regional homogeneity (ReHo was used to analyze the changes in brain function during sham and true acupuncture. Acupuncture at LR3 can specifically activate or deactivate brain areas related to vision, movement, sensation, emotion, and analgesia. The specific alterations in the anterior cingulate gyrus, thalamus, and cerebellar posterior lobe have a crucial effect and provide a valuable reference. Sham acupuncture has a certain effect on psychological processes and does not affect brain areas related to function.

  15. Mapping of the image quality in myocardial scintigraphy: A national study; Kartlaeggning av bildkvalitet vid myokardscintigrafi: en nationell studie

    Energy Technology Data Exchange (ETDEWEB)

    Ohlson, Maria; Gustafsson, Agnetha (Radiofysikavd., Universitetssjukhuset, Linkoeping (SE)); Gretarsdottir, Jakobina (Diagnostik, Sahlgrenska Universitetssjukhuset, Goeteborg (SE)); Olsson, Eva (Fysiologiska kliniken, Universitetssjukhuset, Linkoeping (SE)); Johansson, Lena (Klinisk Fysiologi, Sahlgrenska Universitetssjukhuset, Goeteborg (SE))

    2008-04-15

    The aim of this study was to make a survey over the physical parameters and how they affect the image quality and the final diagnosis for myocardial perfusion SPECT in Sweden. Another aim was to evaluate the need for standardized acquisition and processing protocols for myocardial perfusion SPECT. All thirty nuclear medicine departments in Sweden that perform myocardial perfusion SPECT participated in the study. A thorax heart phantom was used to simulate two patients. All studies were acquired and processed with the parameters used clinically in each hospital respectively. A quantitative and a qualitative evaluation were performed. At each hospital, the local nuclear medicine physician interpreted the images as if they were true patient images. There are great differences in the acquiring and processing parameters used in myocardial perfusion SPECT studies in Sweden. The image quality varies greatly for the different hospital but was approved for the majority of the hospitals. Images from two hospitals were considered to be too poor to be diagnosed. The interpretations of the local nuclear medicine physicians differ but the majority has reported an adequate diagnosis. One third of the hospitals have reported false positive defects. All steps in the chain from the acquisition to the evaluation of the medicine physician must be performed with high quality. The determinative factors are the noise reduction filter, the orientation of the slices in the heart and the judgement of the local medicine physician. The acquiring and processing parameters proposed by EANM should be used. The hospitals are also recommended to investigate in the time and resources available, in order to educate all staff involved in the evaluation of myocardial studies

  16. A preliminary study on cone beam CT image based treatment planning

    International Nuclear Information System (INIS)

    Padmanaban, Sriram; Jeevanandham, Prakash; Boopathy, Raghavendiran; Sukumar, Prabakar; Syam Kumar, S.A.; Kunjithapatham, Bhuvana; Nagarajan, Vivekanandan

    2008-01-01

    Kilovolt Cone beam computed tomography (CBCT) based on flat panel technology is primarily used for positioning verification. However it is required to evaluate the accuracy of dose calculation based on CBCT images for the purpose of re-planning in adaptive radiation therapy (ART). In this study, 3DCRT and IMRT plans were done using both the planning CT and CBCT images and the corresponding variations in dose and MUs were analyzed, hence evaluating the feasibility of using kilovolt CBCT for dose calculation and patient dose verification. (author)

  17. Study of Wide Swath Synthetic Aperture Ladar Imaging Techology

    Directory of Open Access Journals (Sweden)

    Zhang Keshu

    2017-02-01

    Full Text Available Combining synthetic-aperture imaging and coherent-light detection technology, the weak signal identification capacity of Synthetic Aperture Ladar (SAL reaches the photo level, and the image resolution exceeds the diffraction limit of the telescope to obtain high-resolution images irrespective to ranges. This paper introduces SAL, including the development path, technology characteristics, and the restriction of imaging swath. On the basis of this, we propose to integrate the SAL technology for extending its swath. By analyzing the scanning-operation mode and the signal model, the paper explicitly proposes that the former mode will be the developmental trend of the SAL technology. This paper also introduces the flight demonstrations of the SAL and the imaging results of remote targets, showing the potential of the SAL in long-range, high-resolution, and scanning-imaging applications. The technology and the theory of the scanning mode of SAL compensates for the defects related to the swath and operation efficiency of the current SAL. It provides scientific foundation for the SAL system applied in wide swath, high resolution earth observation, and the ISAL system applied in space-targets imaging.

  18. Ocular MR imaging. Evaluation of different coil setups in a phantom study

    International Nuclear Information System (INIS)

    Erb-Eigner, Katharina; Warmuth, Carsten; Taupitz, Matthias; Bertelmann, Eckart; Hamm, Bernd; Asbach, Patrick

    2013-01-01

    Small loop surface coils are generally recommended for ocular magnetic resonance (MR) imaging, but the optimal coil setup has not been systematically investigated. In this phantom study, we investigated which coil setup of those coils available for our MR imaging system provides the highest signal-to-noise ratio (SNR) in ocular MR imaging at 1.5 tesla. Using a phantom to simulate the eyeball and the orbital fat, we employed loop surface coils of 4- and 6-cm diameter and a multi-channel head coil to obtain images using a T 1 -weighted spin-echo sequence and then measured the SNR for each coil and coil combination. Use of the 6-cm loop coil alone yielded the highest mean SNR (27.5). Even in superficial regions (mesial and temporal), the SNR was higher using the 6-cm loop coil (33.6 and 45.5) than the 4-cm loop coil (28.0 and 33.8). Additional use of the head coil reduced the mean SNR to 10.4. This quantitative analysis suggests that use of a 6-cm loop surface coil offers the best results in ocular MR imaging. Combinations of loop coils or additional use of a head coil cannot be recommended because higher noise degrades image quality. (author)

  19. A Web-based telemedicine system for diabetic retinopathy screening using digital fundus photography.

    Science.gov (United States)

    Wei, Jack C; Valentino, Daniel J; Bell, Douglas S; Baker, Richard S

    2006-02-01

    The purpose was to design and implement a Web-based telemedicine system for diabetic retinopathy screening using digital fundus cameras and to make the software publicly available through Open Source release. The process of retinal imaging and case reviewing was modeled to optimize workflow and implement use of computer system. The Web-based system was built on Java Servlet and Java Server Pages (JSP) technologies. Apache Tomcat was chosen as the JSP engine, while MySQL was used as the main database and Laboratory of Neuro Imaging (LONI) Image Storage Architecture, from the LONI-UCLA, as the platform for image storage. For security, all data transmissions were carried over encrypted Internet connections such as Secure Socket Layer (SSL) and HyperText Transfer Protocol over SSL (HTTPS). User logins were required and access to patient data was logged for auditing. The system was deployed at Hubert H. Humphrey Comprehensive Health Center and Martin Luther King/Drew Medical Center of Los Angeles County Department of Health Services. Within 4 months, 1500 images of more than 650 patients were taken at Humphrey's Eye Clinic and successfully transferred to King/Drew's Department of Ophthalmology. This study demonstrates an effective architecture for remote diabetic retinopathy screening.

  20. Tissue Doppler imaging of carotid plaque wall motion: a pilot study

    Directory of Open Access Journals (Sweden)

    Naylor A Ross

    2003-12-01

    Full Text Available Abstract Background Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI of Arterial Wall Motion (AWM and to quantify simple wall motion indices in normal and diseased carotid arteries. Methods 224 normal and diseased carotid arteries (0–100% stenoses were imaged in 126 patients (age 25–88 years, mean 68 ± 11. Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. Results AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. Conclusion Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI.

  1. Studies of Particle Wake Potentials in Plasmas

    Science.gov (United States)

    Ellis, Ian; Graziani, Frank; Glosli, James; Strozzi, David; Surh, Michael; Richards, David; Decyk, Viktor; Mori, Warren

    2011-10-01

    Fast Ignition studies require a detailed understanding of electron scattering, stopping, and energy deposition in plasmas with variable values for the number of particles within a Debye sphere. Presently there is disagreement in the literature concerning the proper description of these processes. Developing and validating proper descriptions requires studying the processes using first-principle electrostatic simulations and possibly including magnetic fields. We are using the particle-particle particle-mesh (PPPM) code ddcMD and the particle-in-cell (PIC) code BEPS to perform these simulations. As a starting point in our study, we examine the wake of a particle passing through a plasma in 3D electrostatic simulations performed with ddcMD and with BEPS using various cell sizes. In this poster, we compare the wakes we observe in these simulations with each other and predictions from Vlasov theory. Prepared by LLNL under Contract DE-AC52-07NA27344 and by UCLA under Grant DE-FG52-09NA29552.

  2. Image and diagnosis quality of X-ray image transmission via cell phone camera: a project study evaluating quality and reliability.

    Directory of Open Access Journals (Sweden)

    Hans Goost

    Full Text Available INTRODUCTION: Developments in telemedicine have not produced any relevant benefits for orthopedics and trauma surgery to date. For the present project study, several parameters were examined during assessment of x-ray images, which had been photographed and transmitted via cell phone. MATERIALS AND METHODS: A total of 100 x-ray images of various body regions were photographed with a Nokia cell phone and transmitted via email or MMS. Next, the transmitted photographs were reviewed on a laptop computer by five medical specialists and assessed regarding quality and diagnosis. RESULTS: Due to their poor quality, the transmitted MMS images could not be evaluated and this path of transmission was therefore excluded. Mean size of transmitted x-ray email images was 394 kB (range: 265-590 kB, SD ± 59, average transmission time was 3.29 min ± 8 (CI 95%: 1.7-4.9. Applying a score from 1-10 (very poor - excellent, mean image quality was 5.8. In 83.2 ± 4% (mean value ± SD of cases (median 82; 80-89%, there was agreement between final diagnosis and assessment by the five medical experts who had received the images. However, there was a markedly low concurrence ratio in the thoracic area and in pediatric injuries. DISCUSSION: While the rate of accurate diagnosis and indication for surgery was high with a concurrence ratio of 83%, considerable differences existed between the assessed regions, with lowest values for thoracic images. Teleradiology is a cost-effective, rapid method which can be applied wherever wireless cell phone reception is available. In our opinion, this method is in principle suitable for clinical use, enabling the physician on duty to agree on appropriate measures with colleagues located elsewhere via x-ray image transmission on a cell phone.

  3. Risk-benefit evaluation for large technological systems

    International Nuclear Information System (INIS)

    Okrent, D.

    1979-01-01

    The related topics of risk-benefit analysis, risk analysis, and risk-acceptance criteria (How safe is safe enough) are of growing importance. An interdisciplinary study on various aspects of these topics, including applications to nuclear power, was recently completed at the University of California, Los Angeles (UCLA), with the support of the National Science Foundation. In addition to more than 30 topical reports and various open-literature publications, a final report (UCLA-ENG-7777) to the study, titled ''A Generalized Evaluation Approach to Risk--Benefit for Large Technological Systems and Its Application to Nuclear Power'', was issued in early 1978. This article briefly summarizes portions of the final report dealing with general aspects of risk-benefit methodology, societal knowledge and perception of risk, and risk-acceptance criteria

  4. SU-E-J-112: Intensity-Based Pulmonary Image Registration: An Evaluation Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, F; Meyer, J; Sandison, G [Department of Radiation Oncology, University of Washington Medical Center, Seattle, WA (United States)

    2015-06-15

    Purpose: Accurate alignment of thoracic CT images is essential for dose tracking and to safely implement adaptive radiotherapy in lung cancers. At the same time it is challenging given the highly elastic nature of lung tissue deformations. The objective of this study was to assess the performances of three state-of-art intensity-based algorithms in terms of their ability to register thoracic CT images subject to affine, barrel, and sinusoid transformation. Methods: Intensity similarity measures of the evaluated algorithms contained sum-of-squared difference (SSD), local mutual information (LMI), and residual complexity (RC). Five thoracic CT scans obtained from the EMPIRE10 challenge database were included and served as reference images. Each CT dataset was distorted by realistic affine, barrel, and sinusoid transformations. Registration performances of the three algorithms were evaluated for each distortion type in terms of intensity root mean square error (IRMSE) between the reference and registered images in the lung regions. Results: For affine distortions, the three algorithms differed significantly in registration of thoracic images both visually and nominally in terms of IRMSE with a mean of 0.011 for SSD, 0.039 for RC, and 0.026 for LMI (p<0.01; Kruskal-Wallis test). For barrel distortion, the three algorithms showed nominally no significant difference in terms of IRMSE with a mean of 0.026 for SSD, 0.086 for RC, and 0.054 for LMI (p=0.16) . A significant difference was seen for sinusoid distorted thoracic CT data with mean lung IRMSE of 0.039 for SSD, 0.092 for RC, and 0.035 for LMI (p=0.02). Conclusion: Pulmonary deformations might vary to a large extent in nature in a daily clinical setting due to factors ranging from anatomy variations to respiratory motion to image quality. It can be appreciated from the results of the present study that the suitability of application of a particular algorithm for pulmonary image registration is deformation-dependent.

  5. Diffusion-weighted MR imaging of cystic lesions of neurocysticercosis: a preliminary study

    International Nuclear Information System (INIS)

    Raffin, Luciana S.; Bacheschi, Luiz A.; Machado, Luis R.; Nobrega, Jose P.S.; Coelho, Christina; Leite, Claudia C.

    2001-01-01

    Neurocysticercosis is an endemic disease in some developing countries. It has pleomorfic clinical and imaging findings, which are variable from patient to patient. In this preliminary note, we studied the magnetic resonance diffusion-weighted images of sixteen patients presenting with cystic lesions of this disease diagnosed by clinical and laboratorial findings. All the lesions had hypointense signal and the similar apparent diffusion coefficient values as the cerebrospinal fluid. (author)

  6. Imaging windows for long-term intravital imaging

    Science.gov (United States)

    Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco

    2014-01-01

    Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure. PMID:28243510

  7. Effects of film/foil interactions on X-ray image quality - experimental studies

    International Nuclear Information System (INIS)

    Maurer, H.J.; Goos, F.

    1985-01-01

    When assessing the quality of X-ray images, the interaction between film and foil should never be left out of account. Except for the case of green-emitting foils which require green-emitting films, films and foils are normally regarded separately, so that many variations are possible. The authors review the interaction between film and foil under practical aspects. Studies published so far have concentrated either on the amplification factor of foils or an the object imaging characteristics of certain films. Systematic studies on the interaction between film and foil have never been carried out. (orig.) [de

  8. The impact of image test bank construction on radiographic interpretation outcomes: A comparison study

    International Nuclear Information System (INIS)

    Hardy, M.; Flintham, K.; Snaith, B.; Lewis, E.F.

    2016-01-01

    Introduction: Assessment of image interpretation competency is commonly undertaken through review of a defined image test bank. Content of these image banks has been criticised for the high percentage of abnormal examinations which contrasts with lower reported incidences of abnormal radiographs in clinical practice. As a result, questions have been raised regarding the influence of prevalence bias on the accuracy of interpretive decision making. This article describes a new and novel approach to the design of musculoskeletal image test banks. Methods: Three manufactured image banks were compiled following a standard academic menu in keeping with previous studies. Three further image test banks were constructed to reflect local clinical workload within a single NHS Trust. Eighteen radiographers, blinded to the method of test bank composition, were randomly assigned 2 test banks to review (1 manufactured, 1 clinical workload). Comparison of interpretive accuracy was undertaken. Results: Inter-rater agreement was moderate to good for all image banks (manufactured: range k = 0.45–0.68; clinical workload: k = 0.49–0.62). A significant difference in mean radiographer sensitivity was noted between test bank designs (manufactured 87.1%; clinical workload 78.5%; p = 0.040, 95% CI = 0.4–16.8; t = 2.223). Relative parity in radiographer specificity and overall accuracy was observed. Conclusion: This study confirms the findings of previous research that high abnormality prevalence image banks over-estimate the ability of observers to identify abnormalities. Assessment of interpretive competency using an image bank that reflects local clinical practice is a better approach to accurately establish interpretive competency and the learning development needs of individual practitioners. - Highlights: • High prevalence image test banks over-estimate the ability of observers. • Clinical workload test banks may better reflect image interpretation competency.

  9. Astrobiology Education and Outreach: New Interdisciplinary Initiatives

    Science.gov (United States)

    Schultz, Greg

    In 1998, UCLA was selected as one of the 11 initial members (5 of which are universities) of the NASA Astrobiology Institute. Concurrently, UCLA implemented a brand new General Education cluster course, GE 70ABC: ``Evolution of the Cosmos and Life,'' which is unique for several reasons. It is (a) interdisciplinary, introducing students to both the life and physical sciences, (b) team-taught by 4 distinguished professors, and 4 advanced graduate teaching fellows, (c) offered for (150) freshmen students exclusively, and (d) a year-long sequence, incorporating lectures, laboratory/discussion sections, field trips, and in the spring quarter, small satellite seminars led by the individual instructors on topics radiating from the cluster theme. Further information about GE 70ABC can be found at the course website (http://www.ess.ucla.edu/Cluster_TOC.html) and the website for UCLA's GE cluster courses (http://www.college.ucla.edu/ge/clusters.htm). This poster will outline the GE 70 content, and describe some of the course's materials, activities, assessment, and student characteristics. Additionally, focus will be placed on the GE 70C seminar course component called ``Life In the Cosmos,'' designed and offered by the poster author for the Spring 1999 quarter. This seminar features a student-centered approach - with lecturing minimized and active learning a key objective - and addresses the extraterrestrial life debate from historical and cultural perspectives as well as the current scientific approaches in astrobiology/bioastronomy.

  10. The influence of store image on customer satisfaction: a case study of a shoe store

    Directory of Open Access Journals (Sweden)

    Tarsis Souza Silva

    2010-01-01

    Full Text Available Knowledge of customers' image of a store is an essential factor in the management of retail outlets. This article presents a case study of the effect of the image customers have of a shoe store on their satisfaction, based on a descriptive and quantitative survey, with the application of a structured questionnaire. We then employed factor analysis to obtain seven store image factors: assortment, convenience, reputation, price, atmosphere, layout and service. The results show that the factor that most affects customer satisfaction in the store studied is service, and that atmosphere and layout have no effect in this respect. The results provide a better understanding of the role store image plays in customer satisfaction and loyalty.

  11. MO-E-BRC-02: MRI-Guided Online Adaptive Radiotherapy: The UCLA Approach to Quality Management

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, J. [University of California, Los Angeles (United States)

    2016-06-15

    Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

  12. MO-E-BRC-02: MRI-Guided Online Adaptive Radiotherapy: The UCLA Approach to Quality Management

    International Nuclear Information System (INIS)

    Lamb, J.

    2016-01-01

    Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

  13. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    International Nuclear Information System (INIS)

    Poortman, Pieter; Lohle, Paul N.M.; Schoemaker, Cees M.; Cuesta, Miguel A.; Oostvogel, Henk J.M.; Lange-de Klerk, Elly S.M. de; Hamming, Jaap F.

    2010-01-01

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  14. Improving the false-negative rate of CT in acute appendicitis-Reassessment of CT images by body imaging radiologists: A blinded prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Poortman, Pieter [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: ppoortman@wlz.nl; Lohle, Paul N.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: plohle@elisabeth.nl; Schoemaker, Cees M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: mcschoemaker@elisabeth.nl; Cuesta, Miguel A. [Department of Surgery, VU Medical Centre, Amsterdam (Netherlands)], E-mail: ma.cuesta@vumc.nl; Oostvogel, Henk J.M. [Department of Surgery, St Elisabeth Hospital, Tilburg (Netherlands)], E-mail: h.oostvogel@elisabeth.nl; Lange-de Klerk, Elly S.M. de [Department of Epidemiology and Biostatistics, VU Medical Centre, Amsterdam (Netherlands)], E-mail: esm.delange@vumc.nl; Hamming, Jaap F. [Department of Surgery, Leiden University Medical Centre (Netherlands)], E-mail: j.f.hamming@lumc.nl

    2010-04-15

    Purpose: To compare the accuracy of computed tomography (CT) analyzed by individual radiology staff members and body imaging radiologists in a non-academic teaching hospital for the diagnosis of acute appendicitis. Patients and methods: In a prospective study 199 patients with suspected acute appendicitis were examined with unenhanced CT. CT images were pre-operatively analyzed by one of the 12 members of the radiology staff. In a later stage two body imaging radiologist reassessed all CT images without knowledge of the surgical findings and without knowledge of the primary CT diagnosis. The results, independently reported, were correlated with surgical and histopathologic findings. Results: In 132 patients (66%) acute appendicitis was found at surgery, in 67 patients (34%) a normal appendix was found. The sensitivity of the primary CT analysis and of the reassessment was 76% and 88%, respectively; the specificity was 84% and 87%; the positive predictive value was 90% and 93%; the negative predictive value was 64% and 78%; and the accuracy was 78% and 87%. Conclusion: Reassessment of CT images for acute appendicitis by body imaging radiologists results in a significant improvement of sensitivity, negative predictive value and accuracy. To prevent false-negative interpretation of CT images in acute appendicitis the expertise of the attending radiologist should be considered.

  15. Trade off study on different envelope detectors for B-mode imaging

    DEFF Research Database (Denmark)

    Schlaikjer, Malene; Bagge, J. P.; Jensen, Jørgen Arendt

    2003-01-01

    sum of the real and imaginary signals. The four detectors were evaluated on in-vivo data acquired with a B-K Medical 2102 scanner interfaced to the sampling system RASMINE. Three data sets were acquired with three different center frequencies. Hundred images were acquired as the transducer was moved......Generation of B-mode images involves envelope detection of the RF-signals. Various detection algorithms are available. A trade off between performance, price, and complexity determines the choice of algorithm in an ultrasound system. A Hilbert Transform (HT) and a subsequent computation...... of the magnitude give the ideal envelope, but the approach (IDE) is expensive and complex. A rectifier (REC) is a simple, low-cost solution, but the performance is severely degraded (especially in dynamic imaging). This study has investigated the possibility of providing a detector with a complexity and cost close...

  16. The amygdala in schizophrenia: a trimodal magnetic resonance imaging study.

    Science.gov (United States)

    Kalus, Peter; Slotboom, Johannes; Gallinat, Jürgen; Wiest, Roland; Ozdoba, Christoph; Federspiel, Andrea; Strik, Werner K; Buri, Caroline; Schroth, Gerhard; Kiefer, Claus

    2005-03-03

    In schizophrenic psychoses, structural and functional alterations of the amygdala have been demonstrated by several neuroimaging studies. However, postmortem examinations on the brains of schizophrenics did not confirm the volume changes reported by volumetric magnetic resonance imaging (MRI) studies. In order to address these contradictory findings and to further elucidate the possibly underlying pathophysiological process of the amygdala, we employed a trimodal MRI design including high-resolution volumetry, diffusion tensor imaging (DTI), and quantitative magnetization transfer imaging (qMTI) in a sample of 14 schizophrenic patients and 14 matched controls. Three-dimensional MRI volumetry revealed a significant reduction of amygdala raw volumes in the patient group, while amygdala volumes normalized for intracranial volume did not differ between the two groups. The regional diffusional anisotropy of the amygdala, expressed as inter-voxel coherence (COH), showed a marked and significant reduction in schizophrenics. Assessment of qMTI parameters yielded significant group differences for the T2 time of the bound proton pool and the T1 time of the free proton pool, while the semi-quantitative magnetization transfer ratio (MTR) did not differ between the groups. The application of multimodal MRI protocols is diagnostically relevant for the differentiation between schizophrenic patients and controls and provides a new strategy for the detection and characterization of subtle structural alterations in defined regions of the living brain.

  17. Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction

    International Nuclear Information System (INIS)

    Shen Zhenglin; Liu Dongyang; Shen Zhenghai; Li Shuping; Zhang Ziyan; Wu Yongjuan; Liu Peijun

    2012-01-01

    Objective: Investigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA. Methods: (1) Experimental study: the target images were subtracted directly, and subtracted again after reverse rotation. Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic. The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line. The subtraction function of DSA by the software was evaluated. (2) Clinical retrospective study: the untreated mask and target images of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software. The target images were processed with and without the software to get two sets of images. (3) Evaluation: four experienced radiologists read and compared the two sets of the images,and graded their findings. Results: (1) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory. (2) In the 15 sets of images, there were only three sets of images deemed optimal after traditional subtraction. After reverse rotation, artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction, and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality. (3) Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration. Conclusion: The registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA

  18. An experimental study of fluidization behavior using flow visualization and image processing

    International Nuclear Information System (INIS)

    Laan, Flavio T. van der; Sefidvash, Farhang; Cornelius, Vanderli

    2000-01-01

    A program of experimental study of fluidization of heavy spherical pellets with water using image processing technique has been started in the Nuclear Engineering Department of the Federal University of Rio Grande do Sul. Fluidization for application in nuclear reactors requires very detailed knowledge of its behavior as the reactivity is closely dependent on the porosity of the fluidized bed. A small modular nuclear reactor concept with suspended core is under study. A modified version of the reactor involves the choice of is to make conical the shape of the reactor core to produce a non-fluctuating bed and consequently guarantee the dynamic stability of the reactor. A 5 mm diameter steel ball are fluidized with water in a conical Plexiglass tube. A pump circulate the water in a loop feeding the room temperature water from the tank into the fluidization system and returning it back to the tank. A controllable valve controls the flow velocity. A high velocity digital CCD camera captures the images of the pellets moving in the fluidized tube. At different flow velocities, the individual pellets can be tracked by processing the sequential frames. A DVT digital tape record stores the images and by acquisition through interface board into a microcomputer. A special program process the data later on. Different algorithm of image treatment determines the velocity fields of the pellets. The behavior of the pellets under different flow velocity and porosity are carefully studied. (author)

  19. A morphological study of the mandibular molar region using reconstructed helical computed tomographic images

    International Nuclear Information System (INIS)

    Tsuno, Hiroaki; Noguchi, Makoto; Noguchi, Akira; Yoshida, Keiko; Tachinami, Yasuharu

    2010-01-01

    This study investigated the morphological variance in the mandibular molar region using reconstructed helical computed tomographic (CT) images. In addition, we discuss the necessity of CT scanning as part of the preoperative assessment process for dental implantation, by comparing the results with the findings of panoramic radiography. Sixty patients examined using CT as part of the preoperative assessment for dental implantation were analyzed. Reconstructed CT images were used to evaluate the bone quality and cross-sectional bone morphology of the mandibular molar region. The mandibular cortical index (MCI) and X-ray density ratio of this region were assessed using panoramic radiography in order to analyze the correlation between the findings of the CT images and panoramic radiography. CT images showed that there was a decrease in bone quality in cases with high MCI. Cross-sectional CT images revealed that the undercuts on the lingual side in the highly radiolucent areas in the basal portion were more frequent than those in the alveolar portion. This study showed that three-dimensional reconstructed CT images can help to detect variances in mandibular morphology that might be missed by panoramic radiography. In conclusion, it is suggested that CT should be included as an important examination tool before dental implantation. (author)

  20. NASA/University Joint Venture (JOVE) Program

    Science.gov (United States)

    Magee-Sauer, Karen P.

    1999-01-01

    Hale-Bopp observations at the NASA IRTF concluded in September 1997. For the post Hale-Bopp period, telescope time was awarded to study comet Giacobini-Zinner in October 1998 at the NASA IRTF. A total of 6 nights were awarded to our team to study the comet where 2 of those 6 nights were awarded to Magee-Sauer as the principal investigator. Other observing trips were awarded to study YSOs (October 1998) and Mars (spring 1999) were Magee-Sauer was a co-investigator. An observing run from July 4 -7 1999 included study of Mars and YSOS. Our group has started to use the NIRSPEC instrument on the Keck II telescope. In collaboration with the development team from UCLA, we obtained images of comet Lee in August 1999. Telescope proposals are submitted each semester for targeted comet observations when a comet is bright enough to observe.

  1. SU-F-J-16: Planar KV Imaging Dose Reduction Study

    Energy Technology Data Exchange (ETDEWEB)

    Gershkevitsh, E; Zolotuhhin, D [North Estonia Medical Centre, Tallinn (Estonia)

    2016-06-15

    Purpose: IGRT has become an indispensable tool in modern radiotherapy with kV imaging used in many departments due to superior image quality and lower dose when compared to MV imaging. Many departments use manufacturer supplied protocols for imaging which are not always optimised between image quality and radiation dose (ALARA). Methods: Whole body phantom PBU-50 (Kyoto Kagaku ltd., Japan) for imaging in radiology has been imaged on Varian iX accelerator (Varian Medical Systems, USA) with OBI 1.5 system. Manufacturer’s default protocols were adapted by modifying kV and mAs values when imaging different anatomical regions of the phantom (head, thorax, abdomen, pelvis, extremities). Images with different settings were independently reviewed by two persons and their suitability for IGRT set-up correction protocols were evaluated. The suitable images with the lowest mAs were then selected. The entrance surface dose (ESD) for manufacturer’s default protocols and modified protocols were measured with RTI Black Piranha (RTI Group, Sweden) and compared. Image quality was also measured with kVQC phantom (Standard Imaging, USA) for different protocols. The modified protocols have been applied for clinical work. Results: For most cases optimized protocols reduced the ESD on average by a factor of 3(range 0.9–8.5). Further reduction in ESD has been observed by applying bow-tie filter designed for CBCT. The largest reduction in dose (12.2 times) was observed for Thorax lateral protocol. The dose was slightly increased (by 10%) for large pelvis AP protocol. Conclusion: Manufacturer’s default IGRT protocols could be optimised to reduce the ESD to the patient without losing the necessary image quality for patient set-up correction. For patient set-up with planar kV imaging the bony anatomy is mostly used and optimization should focus on this aspect. Therefore, the current approach with anthropomorphic phantom is more advantageous in optimization over standard kV quality

  2. Pulmonary ventilation imaging and function studies with krypton-81m

    International Nuclear Information System (INIS)

    Kaplan, E.; Mayron, L.W.; Gergans, G.A.; Friedman, A.M.; Gindler, J.E.

    1976-01-01

    Chronic obstructive lung disease is a significant entity throughout the world. It is etiologically related to smoking, air pollution and mining. To arrest asymptomatic disease, early diagnosis is required, implying an efficacious, reliable and available methodology, which has the potential for screening suspect populations. Krypton-81m is a 13-second radionuclide that emits a 190 keV gamma ray; it may be produced from a rubidium-81-krypton-81m generator and delivery system, devised, produced and evaluated by the authors. The generator effluent, in gaseous form, may be continually inhaled by a subject while static equilibrium images and dynamic studies of ventilation are produced with a gamma scintillation camera system. The wash-in of /sup 81m/Kr produces heterogeneous images, the activity being proportional to regional ventilation due to rapid decay. Minimal ventilatory delays are detectable. Normal subjects and patients with obstructive lung disease have been evaluated by static equilibrium and dynamic studies. The sensitivity of /sup 81m/Kr studies is currently being compared with various other pulmonary function tests, to evaluate its potential as an appropriate screening technique

  3. Three-Dimensional Imaging Using Microcomputed Tomography For Studying Gaharu Morphology

    International Nuclear Information System (INIS)

    Yazid, Khair'iah; Bin Awang, Mat Rasol; Mohamed, Abdul Aziz; Bin Hj Khalid, Mohd Ashhar; Masschaele, Bert; Abdullah, Mohd. Zaid; Saleh, Junita Mohamad

    2010-01-01

    To demonstrates the potential application of the high resolution X-ray micro-CT technique in the analysis of internal structure in Gaharu wood. Gaharu or internationally, Agar wood, is known for its fragrant resinous wood. The hardware device used in this study was an X-ray micro-CT scanner at Center of Tomography (UGCT), CT facility in Ghent University, Belgium. This technique allows the 3D investigation of the internal structure of the wood in a non-destructive way. Most of the data analysis was done with the software VG Studio Max and MATLAB. Here we present some preliminary results from three-dimensional images from a piece of high grade Gaharu. Micro-CT images of the specimens were obtained at 7 μm resolution. Besides a clear distinction between pores and material, some bright white areas occur in the reconstruction images. Not only the volume visualization is helpful, morphological parameters of open-pores and dark resins are calculated from these 3D data set. The micro-CT technique is a valid support for evaluating the pores structure and resin distribution in Gaharu.

  4. Study on the influence of several factors on the quality of SR-XFMT image

    International Nuclear Information System (INIS)

    Deng Biao; Yu Xiaohan; Xu Hongjie

    2007-01-01

    Synchrotron Radiation based X-ray Fluorescent Microtomography (SR-XFMT) is a novel non-destructive technique, which has the ability to reconstruct elemental distributions within a specimen with nondestructive methods. The paper studied the influence of several factors, such as the sampling interval and projections, image reconstruction algorithm and fluorescence signals, on the quality of SR-XFMT image by computer simulation. Some useful conclusions on the quality of SR-XFMT image can be drawn. (authors)

  5. Product-country images as stereotypes: A comparative study of Danish food products in Germany and Turkey

    DEFF Research Database (Denmark)

    Askegaard, Søren; Ger, Güliz

    Executive summary 1. Stereotype research as known from social psychology and political research has only to a limited extent found its way into the field of product-country images. However, recent studies of country-of-origin or country images have taken up stereotypes and related concepts...... such as schemas and cognitive structures. 2. In this study, we examine product-country images in terms of stereotypes. In order to explore stereotypes of country and product meaning, we conducted research on the meanings pertaining to Denmark and Danish food products in two selected cultures: Germany and Turkey...... with Turkish food culture. 5. Other studies show that Danish exporters tend to have a more positive idea of Danish products' and Denmark's image on export markets than our results can confirm. Thus, there seems to be a clash between the way Danish exporters think others see us and the actual image on export...

  6. STUDY OF BODY IMAGE IN PROFESSIONAL DANCERS: A SYSTEMATIC REVIEW

    Directory of Open Access Journals (Sweden)

    Allana Alexandre Cardoso

    Full Text Available ABSTRACT Body image is multidimensional, dynamic, and entirely linked to the body in motion, which entails relevant bodily concerns in the routine of professional dancers, who need to maintain their body aesthetics constantly. The objective was summarizing the scientific production on the body image of professional dancers and to understand how they perceive it. This review is composed by seven studies that investigated professional dancers of classical ballet, jazz and contemporary dance. The results demonstrate that even though they are lean and had appropriate body mass index, professional dancers are dissatisfied with their body and wish to be thinner, that is, professional dancers constitute a risk group for the development of eating disorders.

  7. A preliminary diffusional kurtosis imaging study of Parkinson disease: comparison with conventional diffusion tensor imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kamagata, Koji; Kamiya, Kouhei; Suzuki, Michimasa; Hori, Masaaki; Yoshida, Mariko; Aoki, Shigeki [Juntendo University School of Medicine, Department of Radiology, Bunkyo-ku, Tokyo (Japan); Tomiyama, Hiroyuki; Hatano, Taku; Motoi, Yumiko; Hattori, Nobutaka [Juntendo University School of Medicine, Department of Neurology, Tokyo (Japan); Abe, Osamu [Nihon University School of Medicine, Department of Radiology, Tokyo (Japan); Shimoji, Keigo [National Center of Neurology and Psychiatry Hospital, Department of Radiology, Tokyo (Japan)

    2014-03-15

    Diffusional kurtosis imaging (DKI) is a more sensitive technique than conventional diffusion tensor imaging (DTI) for assessing tissue microstructure. In particular, it quantifies the microstructural integrity of white matter, even in the presence of crossing fibers. The aim of this preliminary study was to compare how DKI and DTI show white matter alterations in Parkinson disease (PD). DKI scans were obtained with a 3-T magnetic resonance imager from 12 patients with PD and 10 healthy controls matched by age and sex. Tract-based spatial statistics were used to compare the mean kurtosis (MK), mean diffusivity (MD), and fractional anisotropy (FA) maps of the PD patient group and the control group. In addition, a region-of-interest analysis was performed for the area of the posterior corona radiata and superior longitudinal fasciculus (SLF) fiber crossing. FA values in the frontal white matter were significantly lower in PD patients than in healthy controls. Reductions in MK occurred more extensively throughout the brain: in addition to frontal white matter, MK was lower in the parietal, occipital, and right temporal white matter. The MK value of the area of the posterior corona radiata and SLF fiber crossing was also lower in the PD group. DKI detects changes in the cerebral white matter of PD patients more sensitively than conventional DTI. In addition, DKI is useful for evaluating crossing fibers. By providing a sensitive index of brain pathology in PD, DKI may enable improved monitoring of disease progression. (orig.)

  8. Dynamic PET simulator via tomographic emission projection for kinetic modeling and parametric image studies.

    Science.gov (United States)

    Häggström, Ida; Beattie, Bradley J; Schmidtlein, C Ross

    2016-06-01

    To develop and evaluate a fast and simple tool called dpetstep (Dynamic PET Simulator of Tracers via Emission Projection), for dynamic PET simulations as an alternative to Monte Carlo (MC), useful for educational purposes and evaluation of the effects of the clinical environment, postprocessing choices, etc., on dynamic and parametric images. The tool was developed in matlab using both new and previously reported modules of petstep (PET Simulator of Tracers via Emission Projection). Time activity curves are generated for each voxel of the input parametric image, whereby effects of imaging system blurring, counting noise, scatters, randoms, and attenuation are simulated for each frame. Each frame is then reconstructed into images according to the user specified method, settings, and corrections. Reconstructed images were compared to MC data, and simple Gaussian noised time activity curves (GAUSS). dpetstep was 8000 times faster than MC. Dynamic images from dpetstep had a root mean square error that was within 4% on average of that of MC images, whereas the GAUSS images were within 11%. The average bias in dpetstep and MC images was the same, while GAUSS differed by 3% points. Noise profiles in dpetstep images conformed well to MC images, confirmed visually by scatter plot histograms, and statistically by tumor region of interest histogram comparisons that showed no significant differences (p dynamic PET and parametric images, and demonstrated that it generates both images and subsequent parametric images with very similar noise properties to those of MC images, in a fraction of the time. They believe dpetstep to be very useful for generating fast, simple, and realistic results, however since it uses simple scatter and random models it may not be suitable for studies investigating these phenomena. dpetstep can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.

  9. Molecular photoacoustic imaging

    Directory of Open Access Journals (Sweden)

    Frogh Jafarian Dehkordi

    2015-04-01

    Full Text Available Background: Hybrid imaging modalities which simultaneously benefit from capabilities of combined modalities provides an opportunity to modify quality of the images which can be obtained by each of the combined imaging systems. One of the imaging modalities, emerged in medical research area as a hybrid of ultrasound imaging and optical imaging, is photoacoustic imaging which apply ultrasound wave generated by tissue, after receiving laser pulse, to produce medical images. Materials and Methods: In this review, using keywords such as photoacoustic, optoacoustic, laser-ultrasound, thermoacoustic at databases such as PubMed and ISI, studies performed in the field of photoacoustic and related findings were evaluated. Results: Photoacoustic imaging, acquiring images with high contrast and desired resolution, provides an opportunity to perform physiologic and anatomic studies. Because this technique does not use ionizing radiation, it is not restricted by the limitation of the ionizing-based imaging systems therefore it can be used noninvasively to make images from cell, vessels, whole body imaging of the animal and distinguish tumor from normal tissue. Conclusion: Photoacoustic imaging is a new method in preclinical researches which can be used in various physiologic and anatomic studies. This method, because of application of non-ionizing radiation, may resolve limitation of radiation based method in diagnostic assessments.

  10. A survey of MRI-based medical image analysis for brain tumor studies

    Science.gov (United States)

    Bauer, Stefan; Wiest, Roland; Nolte, Lutz-P.; Reyes, Mauricio

    2013-07-01

    MRI-based medical image analysis for brain tumor studies is gaining attention in recent times due to an increased need for efficient and objective evaluation of large amounts of data. While the pioneering approaches applying automated methods for the analysis of brain tumor images date back almost two decades, the current methods are becoming more mature and coming closer to routine clinical application. This review aims to provide a comprehensive overview by giving a brief introduction to brain tumors and imaging of brain tumors first. Then, we review the state of the art in segmentation, registration and modeling related to tumor-bearing brain images with a focus on gliomas. The objective in the segmentation is outlining the tumor including its sub-compartments and surrounding tissues, while the main challenge in registration and modeling is the handling of morphological changes caused by the tumor. The qualities of different approaches are discussed with a focus on methods that can be applied on standard clinical imaging protocols. Finally, a critical assessment of the current state is performed and future developments and trends are addressed, giving special attention to recent developments in radiological tumor assessment guidelines.

  11. A small animal image guided irradiation system study using 3D dosimeters

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Admovics, John

    2015-01-01

    In a high resolution image-guided small animal irradiation platform, a cone beam computed tomography (CBCT) is integrated with an irradiation unit for precise targeting. Precise quality assurance is essential for both imaging and irradiation components. The conventional commissioning techniques with films face major challenges due to alignment uncertainty and labour intensive film preparation and scanning. In addition, due to the novel design of this platform the mouse stage rotation for CBCT imaging is perpendicular to the gantry rotation for irradiation. Because these two rotations are associated with different mechanical systems, discrepancy between rotation isocenters exists. In order to deliver x-ray precisely, it is essential to verify coincidence of the imaging and the irradiation isocenters. A 3D PRESAGE dosimeter can provide an excellent tool for checking dosimetry and verifying coincidence of irradiation and imaging coordinates in one system. Dosimetric measurements were performed to obtain beam profiles and percent depth dose (PDD). Isocentricity and coincidence of the mouse stage and gantry rotations were evaluated with starshots acquired using PRESAGE dosimeters. A single PRESAGE dosimeter can provide 3 -D information in both geometric and dosimetric uncertainty, which is crucial for translational studies

  12. A survey of MRI-based medical image analysis for brain tumor studies

    International Nuclear Information System (INIS)

    Bauer, Stefan; Nolte, Lutz-P; Reyes, Mauricio; Wiest, Roland

    2013-01-01

    MRI-based medical image analysis for brain tumor studies is gaining attention in recent times due to an increased need for efficient and objective evaluation of large amounts of data. While the pioneering approaches applying automated methods for the analysis of brain tumor images date back almost two decades, the current methods are becoming more mature and coming closer to routine clinical application. This review aims to provide a comprehensive overview by giving a brief introduction to brain tumors and imaging of brain tumors first. Then, we review the state of the art in segmentation, registration and modeling related to tumor-bearing brain images with a focus on gliomas. The objective in the segmentation is outlining the tumor including its sub-compartments and surrounding tissues, while the main challenge in registration and modeling is the handling of morphological changes caused by the tumor. The qualities of different approaches are discussed with a focus on methods that can be applied on standard clinical imaging protocols. Finally, a critical assessment of the current state is performed and future developments and trends are addressed, giving special attention to recent developments in radiological tumor assessment guidelines. (topical review)

  13. Initial study of magnetization transfer contrast MR imaging of the knee at 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hiroshi; Echigo, Junko; Niitsu, Mamoru; Anno, Izumi; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Nakai, Toshiharu; Sato, Hiroshi; Tsukamoto, Tetsuji

    1998-10-01

    It has been reported that various image sequences, including magnetization transfer contrast (MTC) were effective in evaluating articular cartilage. It is difficult to identify cartilaginous structures, however, using conventional MR imaging because of low spatial resolution and low signal-to-noise (S/N) ratio. The purpose of the present study was to evaluate the optimal imaging sequences with MTC pulse at 3 T and to assess the feasibility of the clinical application thereof. Five porcine knees were studied using varying imaging parameters (frequency offset, flip angle (FA) and echo time (TE)) combined with off-resonance sinc radiation pulses. The effect of MTC was analyzed by dividing the signal intensity of MTC GRE images by that of conventional GRE images (Ms/Mo). MTC images were obtained with a low specific absorption rate (SAR). With an offset frequency of 1.5 kHz (repetition time/TE/FA=60 ms/8 ms/30 degrees), the mean Ms/Mo of articular cartilage and meniscus was 0.70 and 0.65, respectively. An FA of 20 to 30 degrees and a TE of 11 to 12 ms appear to be optimal parameters at 3 T with MTC pulse because of the higher S/N ratio of cartilage and higher contrast-to-noise ratio of cartilage relative to that of distilled water. These findings suggest that MTC at 3 T may be feasible and effective for assessment of cartilage and meniscus in clinical applications. (author)

  14. Evaluation of Color Settings in Aerial Images with the Use of Eye-Tracking User Study

    Science.gov (United States)

    Mirijovsky, J.; Popelka, S.

    2016-06-01

    The main aim of presented paper is to find the most realistic and preferred color settings for four different types of surfaces on the aerial images. This will be achieved through user study with the use of eye-movement recording. Aerial images taken by the unmanned aerial system were used as stimuli. From each image, squared crop area containing one of the studied types of surfaces (asphalt, concrete, water, soil, and grass) was selected. For each type of surface, the real value of reflectance was found with the use of precise spectroradiometer ASD HandHeld 2 which measures the reflectance. The device was used at the same time as aerial images were captured, so lighting conditions and state of vegetation were equal. The spectral resolution of the ASD device is better than 3.0 nm. For defining the RGB values of selected type of surface, the spectral reflectance values recorded by the device were merged into wider groups. Finally, we get three groups corresponding to RGB color system. Captured images were edited with the graphic editor Photoshop CS6. Contrast, clarity, and brightness were edited for all surface types on images. Finally, we get a set of 12 images of the same area with different color settings. These images were put into the grid and used as stimuli for the eye-tracking experiment. Eye-tracking is one of the methods of usability studies and it is considered as relatively objective. Eye-tracker SMI RED 250 with the sampling frequency 250 Hz was used in the study. As respondents, a group of 24 students of Geoinformatics and Geography was used. Their task was to select which image in the grid has the best color settings. The next task was to select which color settings they prefer. Respondents' answers were evaluated and the most realistic and most preferable color settings were found. The advantage of the eye-tracking evaluation was that also the process of the selection of the answers was analyzed. Areas of Interest were marked around each image in the

  15. Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

    Directory of Open Access Journals (Sweden)

    Banari Bahnamiri Sh

    2015-03-01

    Full Text Available Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT device is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in SPECT imaging in nuclear medicine is the use of an appropriate collimator for a certain radiopharmaceutical feature in order to create the best image as it can be effective in the quantity of Full Width at Half Maximum (FWHM which is the main parameter in spatial resolution. Method: In this research, the simulation of the detector and collimator of SPECT imaging device, Model HD3 made by Philips Co. and the investigation of important factors on the collimator were carried out using MCNP-4c code. Results: The results of the experimental measurments and simulation calculations revealed a relative difference of less than 5% leading to the confirmation of the accuracy of conducted simulation MCNP code calculation. Conclusion: This is the first essential step in the design and modelling of new collimators used for creating high quality images in nuclear medicine

  16. Annotating images by mining image search results

    NARCIS (Netherlands)

    Wang, X.J.; Zhang, L.; Li, X.; Ma, W.Y.

    2008-01-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search

  17. A model of destination image promotion with a case study of Nanjing, P. R. China

    Science.gov (United States)

    Xiang Li; Hans Vogelsong

    2003-01-01

    Destination image has long been a popular research topic in tourism studies. However, methods used to integrate image in real marketing practice and evaluating the market performance in a systematic way are still puzzling to practitioners. A destination image promotion model is proposed in this paper as an effort to solve the problem. The roles of some major factors...

  18. Imaging findings of primary breast sarcoma: Results of a first multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, Susanne, E-mail: susanne.wienbeck@med.uni-goettingen.de [University of Göttingen, Institute of Diagnostic and Interventional Radiology, Robert- Koch-Str. 40, 37075 Göttingen (Germany); Meyer, Hans Jonas [University Hospital Halle, Department of Radiology, Ernst-Grube-Str. 40, 06120 Halle (Germany); Herzog, Aimee [University of Jena, Institute of Diagnostic and Interventional Radiology, Erlanger Allee 101, 07747 Jena (Germany); Nemat, Sogand [University of Saarland, Clinic for Diagnostic and Interventional Radiology, Kirrberger Str. 100, 66424 Homburg (Germany); Teifke, Andrea [University of Mainz, Department of Diagnostic and Interventional Radiology, Langenbeckstr. 1, 55131 Mainz (Germany); Heindel, Walter [University of Münster, Institute of Clinical Radiology, Albert-Schweitzer-Str. 33, 48149 Münster (Germany); Schäfer, Fritz [University of Kiel, Institute of Radiology and Neuroradiology, Arnold-Heller-Str. 3, 24105 Kiel (Germany); Kinner, Sonja [University of Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, 45147 Essen (Germany); Müller-Schimpfle, Markus [Clinic Frankfurt Höchst, Department of Radiology, Gotenstr. 6, 65929 Frankfurt am Main (Germany); Surov, Alexey [University Hospital Halle, Department of Radiology, Ernst-Grube-Str. 40, 06120 Halle (Germany); University of Leipzig, Department of Diagnostic and Interventional Radiology, Liebigstr. 20, 04103 Leipzig (Germany)

    2017-03-15

    Purpose: To investigate imaging findings in patients with primary breast sarcoma (PBS). Materials and methods: A retrospective search in the databases of 10 radiological departments in Germany from 2000 to 2011 was performed. Only histologically proven cases of PBS were included into the study. Mammography was available in 31 patients (33 lesions), ultrasound images in 24 patients (24 lesions), and for 10 patients (14 lesions) magnetic resonance imaging (MRI) of the breast was performed. The breast findings were classified according to the American College of Radiology Breast Imaging Reporting and Data Systems (BI-RADS) 5th edition categories. Collected data were evaluated by means of descriptive statistics. Results: Forty-two female patients (mean age 62.0 years, range, 30–86 years) were included in the study. Clinically, all women had painless lumps. Irregular (53.3% [16/30]) or oval (30.0% [9/30]) mass with indistinct (73.3% [22/30]) or microlobulated (10% [3/30]) margins were common findings on mammograms. Ultrasound revealed typically an irregular (79.2% [19/24]), hypoechoic (62.5% [15/24]) mass, with indistinct margins (79.2% [19/24]), and posterior acoustic shadowing (79.2% [19/24]). MRI showed irregular masses (81.8% [9/11]) with irregular or spiculated margins, and a rapid initial signal increase with a delayed washout in kinetic analysis. Conclusion: Overall, PBS has no pathognomonic imaging features and can mimic those of invasive mammary carcinoma. Breast sarcoma should be taken into the differential diagnosis of breast findings described above.

  19. University of California, San Diego (UCSD) Sky Imager Cloud Position Study Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Kleissl, J. [Univ. of California, San Diego, CA (United States); Urquhart, B. [Univ. of California, San Diego, CA (United States); Ghonima, M. [Univ. of California, San Diego, CA (United States); Dahlin, E. [Univ. of California, San Diego, CA (United States); Nguyen, A. [Univ. of California, San Diego, CA (United States); Kurtz, B. [Univ. of California, San Diego, CA (United States); Chow, C. W. [Univ. of California, San Diego, CA (United States); Mejia, F. A. [Univ. of California, San Diego, CA (United States)

    2016-04-01

    During the University of California, San Diego (UCSD) Sky Imager Cloud Position Study, two University of California, San Diego Sky Imagers (USI) (Figure 1) were deployed the U.S. Department of Energy(DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains SGP) research facility. The UCSD Sky Imagers were placed 1.7 km apart to allow for stereographic determination of the cloud height for clouds over approximately 1.5 km. Images with a 180-degree field of view were captured from both systems during daylight hours every 30 seconds beginning on March 11, 2013 and ending on November 4, 2013. The spatial resolution of the images was 1,748 × 1,748, and the intensity resolution was 16 bits using a high-dynamic-range capture process. The cameras use a fisheye lens, so the images are distorted following an equisolid angle projection.

  20. Progress of PET imaging in the study of neural stem cell transplantation treating Parkinson's disease

    International Nuclear Information System (INIS)

    Tan Haibo; Liu Xingdang

    2004-01-01

    PET imaging has important value in the study of neural stem cell transplantation treating Parkinson's disease, especial in the evaluation of the effect, the study of treating mechanisms and the comparation of effect in different transplantation places. PET imaging as a non-invasive method plays a more and more important role in the study of neural stem cell transplantation treating Parkinson's disease. (authors)