WorldWideScience

Sample records for two-sided injection method

  1. Krylov-Schur-Type restarts for the two-sided arnoldi method

    NARCIS (Netherlands)

    Zwaan, I.N.; Hochstenbach, M.E.

    2017-01-01

    We consider the two-sided Arnoldi method and propose a two-sided Krylov-Schurtype restarting method. We discuss the restart for standard Rayleigh-Ritz extraction as well as harmonic Rayleigh-Ritz extraction. Additionally, we provide error bounds for Ritz values and Ritz vectors in the context of

  2. Non-solenoidal Startup with High-Field-Side Local Helicity Injection on the Pegasus ST

    Science.gov (United States)

    Perry, J. M.; Bodner, G. M.; Bongard, M. W.; Burke, M. G.; Fonck, R. J.; Pachicano, J. L.; Pierren, C.; Richner, N. J.; Rodriguez Sanchez, C.; Schlossberg, D. J.; Reusch, J. A.; Weberski, J. D.

    2017-10-01

    Local Helicity Injection (LHI) is a non-solenoidal startup technique utilizing electron current injectors at the plasma edge to initiate a tokamak-like plasma at high Ip . Recent experiments on Pegasus explore the inherent tradeoffs between high-field-side (HFS) injection in the lower divertor region and low-field-side (LFS) injection at the outboard midplane. Trade-offs include the relative current drive contributions of HI and poloidal induction, and the magnetic geometry required for relaxation to a tokamak-like state. HFS injection using a set of two increased-area injectors (Ainj = 4 cm2, Vinj 1.5 kV, and Iinj 8 kA) in the lower divertor is demonstrated over the full range of toroidal field available on Pegasus (BT 0 = 10) attainable with LHI and the favorable stability of the ultra-low aspect ratio, low-li LHI-driven plasmas allow access to high βt-up to 100 % , as indicated by kinetically-constrained equilibrium reconstructions. Work supported by US DOE Grant DE-FG02-96ER54375.

  3. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Song Ee; Oh, Young Taik [Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-09-15

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4{+-}1.78: group 2, 2.8{+-}1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  4. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    International Nuclear Information System (INIS)

    Baek, Song Ee; Oh, Young Taik; Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul

    2010-01-01

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4±1.78: group 2, 2.8±1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  5. Comparison of Two Local Anesthesia Injection Methods During a Transrectal Ultrasonography-guided Prostate Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Song Ee; Oh, Young Taik [Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jang Hwan; Rha, Koon Ho; Hong, Sung Joon; Yang, Seung Choul [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-09-15

    To compare the effectiveness of 2 injection methods of lidocaine during a transrectal ultrasound (TRUS)-guided prostate biopsy for pain control and complication rates. We retrospectively evaluated patients who underwent a TRUS-guided prostate biopsy from March 2005 to March 2006. One hundred patients were categorized into two groups based on injection method. For group 1, 10 mL of 1% lidocaine was injected bilaterally at the junction of the seminal vesicle and prostate and for group 2, into Denonvilliers' fascia. Pain scores using a visual analog scale (VAS) as well as immediate and delayed complication rates were evaluated. The mean VAS score showed no significant differences between the groups (group 1, 3.4{+-}1.78: group 2, 2.8{+-}1.3: p = 0.062). The difference in delayed complication rates and incidence of hematuria, hemospermia, and blood via the rectum was not significant between groups. However, two patients in group 1 complained of symptoms immediately after local anesthesia: one of tinnitus and the other of mild dizziness. There were no significant differences between pain control and complication rates between the 2 lidocaine injection methods. However, injection into Denonvilliers' fascia is thought to have less potential risk

  6. Outcome analysis of two different injection solutions for epidural injection in radicular lumbar backache syndromes

    International Nuclear Information System (INIS)

    Saqib, M.; Mukhtar, M.; Bhatti, S.N; Afridi, E.A.K.; Khan, R.

    2017-01-01

    Background: Backache is a significant source of disability and suffering in our society. The treatment modalities need continued enhancement in order to achieve the desired goals of lowering morbidity and financial losses while improving the response of the patient. Methods: This prospective comparative study was conducted at the department of Orthopaedics and Spine Surgery, Khyber Teaching Hospital Peshawar from July 2013 to June 2015. Two interventional groups were designated; Group 1 was comprised of 54 patients who were injected with epidural bupivacaine plus methylprednisolone while Group 2 included 55 patients who were injected with bupivacaine only. Outcome was assessed using the visual analogue scale and Oswestry disability index (ODI). Results: Fifty-five female and 54 male patients with mean age 49.37 years+-10.46 SD, Mean symptoms duration was 15.01 months+-9.32 SD. Common presenting symptoms were backache (77.1 percent), lower limbs pain (66.1 percent), dermatomal paresthesias (54.1 percent) and neurogenic claudication in 57.8 percent patients. The mean visual analogue score (VAS) after injection was 3.18+-1.29 while mean ODI after injection was 23.615. There was a statistically significant reduction in VAS scores (2-sided p=0.003, OR =4.03, 95 percent CI: 1.535-10.60) following the injection. Conclusion: An epidural spinal injection is a viable option for achieving relief of pain and improves functioning in individuals with radicular backache. However, further research is advised in order to clarify the role of ESI for long-term relief. (author)

  7. Harmony Search for Balancing Two-sided Assembly Lines

    Directory of Open Access Journals (Sweden)

    Hindriyanto Dwi Purnomo

    2012-01-01

    Full Text Available Two-sided assembly lines balancing problems are important problem for large-sized products such as cars and buses, in which, tasks operations can be performed in the two sides of the line. In this paper, Harmony Search algorithm is proposed to solve two-sided assembly lines balancing problems type-I (TALBP-I. The proposed method adopts the COMSOAL heuristic and specific features of TALBP in the Harmony operators – the harmony memory consideration, random selection and pitch adjustment – in order to maintain the local and global search. The proposed method is evaluated based on 6 benchmark problems that are commonly used in TALBP. The experiment results show that the proposed method work well and produces better solution than the heuristic method and genetic algorithm.

  8. A Diffusion Model for Two-sided Service Systems

    Science.gov (United States)

    Homma, Koichi; Yano, Koujin; Funabashi, Motohisa

    A diffusion model is proposed for two-sided service systems. ‘Two-sided’ refers to the existence of an economic network effect between two different and interrelated groups, e.g., card holders and merchants in an electronic money service. The service benefit for a member of one side depends on the number and quality of the members on the other side. A mathematical model by J. H. Rohlfs explains the network (or bandwagon) effect of communications services. In Rohlfs' model, only the users' group exists and the model is one-sided. This paper extends Rohlfs' model to a two-sided model. We propose, first, a micro model that explains individual behavior in regard to service subscription of both sides and a computational method that drives the proposed model. Second, we develop macro models with two diffusion-rate variables by simplifying the micro model. As a case study, we apply the models to an electronic money service and discuss the simulation results and actual statistics.

  9. [Injection Pressure Evaluation of the New Venous Catheter with Side Holes for Contrast-enhanced CT/MRI].

    Science.gov (United States)

    Fukuda, Junya; Arai, Keisuke; Miyazawa, Hitomi; Kobayashi, Kyouko; Nakamura, Junpei; Suto, Takayuki; Tsushima, Yoshito

    2018-01-01

    The simulation study was conducted for the new venous catheter with side holes of contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) to evaluate the infusion pressure on four contrast media and several injection speeds. All infusion pressure of the new venous catheter with side holes were less than 15 kg/cm 2 as limitation of extension tube and also reduced the infusion pressure by 15% at the maximum compared to the catheter with single hole. The results suggest that the new venous catheter with side holes can reduce the infusion pressure by power injection of contrast-enhanced CT and MRI.

  10. Design of a microscopic electrical impedance tomography system using two current injections

    International Nuclear Information System (INIS)

    Liu, Qin; Oh, Tong In; Wi, Hun; Woo, Eung Je; Lee, Eun Jung; Seo, Jin Keun

    2011-01-01

    We describe a novel design of a microscopic electrical impedance tomography (micro-EIT) system for long-term noninvasive monitoring of cell or tissue cultures. The core of the micro-EIT system is a sample container including two pairs of current-injection electrodes and 360 voltage-sensing electrodes. In designing the container, we took advantage of a hexagonal structure with fixed dimensions and electrode configuration. This eliminated technical difficulties related to the unknown irregular boundary geometry of an imaging object in conventional medical EIT. Attaching a pair of large current-injection electrodes fully covering the left and right sides of the hexagonal container, we generated uniform parallel current density inside the container filled with saline. The 360 voltage-sensing electrodes were placed on the front, bottom and back sides of the hexagonal container in three sets of 8 × 15 arrays with equal gaps between them. We measured voltage differences between all neighboring pairs along the direction of the parallel current pathway. For the homogeneous container, all measured voltages must be the same since the voltage changes linearly along that direction. Any anomaly in the container perturbed the current pathways and therefore equipotential lines to produce different differential voltage data. For conductivity image reconstructions, we adopted a lately developed image reconstruction algorithm for this electrode configuration to first produce projected conductivity images on the front, bottom and back sides. Using a backprojection method, we reconstructed three-dimensional conductivity images from those projection images. To improve the image quality and also to meet the mathematical requirement on the uniqueness of a reconstructed image, we used a second pair of thin and long current-injection electrodes located at the middle of the front and back sides. This paper describes the design and construction of such a micro-EIT system with experimental

  11. Modeling and experimental studies of a side band power re-injection locked magnetron

    Science.gov (United States)

    Ye, Wen-Jun; Zhang, Yi; Yuan, Ping; Zhu, Hua-Cheng; Huang, Ka-Ma; Yang, Yang

    2016-12-01

    A side band power re-injection locked (SBPRIL) magnetron is presented in this paper. A tuning stub is placed between the external injection locked (EIL) magnetron and the circulator. Side band power of the EIL magnetron is reflected back to the magnetron. The reflected side band power is reused and pulled back to the central frequency. A phase-locking model is developed from circuit theory to explain the process of reuse of side band power in SBPRIL magnetron. Theoretical analysis proves that the side band power is pulled back to the central frequency of the SBPRIL magnetron, then the amplitude of the RF voltage increases and the phase noise performance is improved. Particle-in-cell (PIC) simulation of a 10-vane continuous wave (CW) magnetron model is presented. Computer simulation predicts that the frequency spectrum’s peak of the SBPRIL magnetron has an increase of 3.25 dB compared with the free running magnetron. The phase noise performance at the side band offset reduces 12.05 dB for the SBPRIL magnetron. Besides, the SBPRIL magnetron experiment is presented. Experimental results show that the spectrum peak rises by 14.29% for SBPRIL magnetron compared with the free running magnetron. The phase noise reduces more than 25 dB at 45-kHz offset compared with the free running magnetron. Project supported by the National Basic Research Program of China (Grant No. 2013CB328902) and the National Natural Science Foundation of China (Grant No. 61501311).

  12. Assessment of side effects induced by injection of different adjuvant/antigen combinations in rabbits and mice

    NARCIS (Netherlands)

    Leenaars, P.P.A.M.; Koedam, M.A.; Wester, P.W.; Baumans, V.; Claassen, E.; Hendriksen, C.F.M.

    1998-01-01

    We evaluated the side effects induced by injection of Freund's adjuvant (FA) and alternative adjuvants combined with different antigens. Rabbits and mice were injected subcutaneously, intramuscularly (rabbits) and intraperitoneally (mice) with different adjuvants (FA, Specol, RIBI, TiterMax,

  13. Comparison Between the Two-Injection Technique and the Four-Injection Technique in Axillary Brachial Plexus Block with Articaine.

    Science.gov (United States)

    Ertikin, Aysun; Argun, Güldeniz; Mısırlıoğlu, Mesut; Aydın, Murat; Arıkan, Murat; Kadıoğulları, Nihal

    2017-10-01

    In this study, we aimed to compare axillary brachial plexus block using the two-injection and four-injection techniques assisted with ultrasonography (USG) and nerve stimulator in patients operated for carpal tunnel syndrome with articaine. To evaluate which technique is more effective, we compared the onset time, effectiveness, and duration of block procedures, patient satisfaction, adverse effect of the drug, and complication rates of the motor and sensory blocks. Sixty patients were randomly divided into two groups. A mixture of physiologic serum added to articain with NaHCO 3 (30 mL) was injected into the patients' axilla in both the groups. After the blockage of the musculocutaneous nerve in both the groups, the median nerve in the two-injection group and the median nerve, ulnar nerve, and radial nerve in the four-injection group were blocked. In brachial plexus nerves, sensorial blockage was evaluated with pinprick test, and motor block was evaluated by contraction of the muscles innervated by each nerve. The adverse effects and complications, visual analog scale (VAS) values during the operation, and post-operative patient satisfaction were recorded. Sufficient analgesia and anaesthesia were achieved with no need for an additional local anaesthetics in both the groups. Furthermore, additional sedation requirements were found to be similar in both the groups. A faster rate and a more effective complete block were achieved in more patients from the four-injection group. In the two-injection group, the block could not be achieved for N. radialis in one patient. All other nerves were successfully blocked. Whereas the blockage procedure lasted longer in the four-injection group, the VAS values recorded during the blockage procedure were higher in the four-injection group. No statistical difference was found with regard to patient satisfaction, and no adverse effects and complications were observed in any group. Although the multi-injection method takes more time

  14. The study of two methods for high pressure injection in CT enhancement to display the aortic dissecting aneurysm

    International Nuclear Information System (INIS)

    Wang Yang; Zhu Bin; Zhang Zhen

    2008-01-01

    Objective: To discuss the consequences of two different methods of high pressure injection in CT contrast enhancement to display the aortic dissecting aneurysm. Methods: 100 patients underwent Lightspeed 16 MS CT with contrast enhancement of Stellant D high pressure injector (Medrad), injecting speed of 4.0 mL/s and 80 ml dosage of contrast medium. All patients were divided into A and B groups with 50 in each. The single high pressure injection was applied to A group without isotonic Na chloride flush. B group underwent the same high pressure injection and followed by isotonic Na chloride flush. The method of evaluation was carried out by double blind observation. Results: A group revealed radiologic artifact up to 40 cases with positive rate of 80%. B group demonstrated the same kind of radiologic artifact in 26 cases with positive rate of 52%. Conclusions: Using normal saline (sodium chloride solution)flush after high pressure injection of contrast medium during MSCT angiography is obviously better to demonstrate the internal structures of treatvessels. (authors)

  15. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  16. Two-Step Injection Method for Collecting Digital Evidence in Digital Forensics

    Directory of Open Access Journals (Sweden)

    Nana Rachmana Syambas

    2015-01-01

    Full Text Available In digital forensic investigations, the investigators take digital evidence from computers, laptops or other electronic goods. There are many complications when a suspect or related person does not want to cooperate or has removed digital evidence. A lot of research has been done with the goal of retrieving data from flash memory or other digital storage media from which the content has been deleted. Unfortunately, such methods cannot guarantee that all data will be recovered. Most data can only be recovered partially and sometimes not perfectly, so that some or all files cannot be opened. This paper proposes the development of a new method for the retrieval of digital evidence called the Two-Step Injection method (TSI. It focuses on the prevention of the loss of digital evidence through the deletion of data by suspects or other parties. The advantage of this method is that the system works in secret and can be combined with other digital evidence applications that already exist, so that the accuracy and completeness of the resulting digital evidence can be improved. An experiment to test the effectiveness of the method was set up. The developed TSI system worked properly and had a 100% success rate.

  17. Injection Pressure as a Marker of Intraneural Injection in Procedures of Peripheral Nerves Blockade

    Directory of Open Access Journals (Sweden)

    Ilvana Vučković

    2006-11-01

    Full Text Available The blockade of peripheral nerves carries a certain risk of unwanted complications, which can follow after unintentional intraneural injection of a local anesthetic. Up till today, the research of measuring injection pressure has been based on animal models, even though the histological structure of periphery nerve is different for animal and human population, so the application pressure which presages intraneural injection in human population is still unknown. As material in performing this study there have been used 12 Wistar rats and 12 delivered stillborns. After bilateral access to the median nerve, we applied 3 ml of 2% lidocaine with epinephrine, with the help of automatic syringe charger. The needle was at first placed perineural on one side, and then intraneural on the other side of both examination groups. During every application the pressure values were monitored using the manometer, and then they were analyzed by special software program BioBench. All perineural injections resulted with the pressure < or = 27.92 kPa, while the majority of intraneural injections were combined with the injectionpressure > or = 69.8 kPa. The difference between intraneural and perineural injection pressures for the two different examination groups (rats and delivered stillborns was not statistically significant (P>0.05. As prevention from intraneural injections today are in use two methods: the method of causing paresthesia or the method of using the peripheral nerve stimulator. However the nerve injury can still occur, independent from the technique used. If our results are used in clinical practice on human population, than the high injection pressure could be the markerof intraneural lodging of a needle.

  18. Mitigation of rotational instability of high-beta field-reversed configuration by double-sided magnetized plasmoid injection

    Energy Technology Data Exchange (ETDEWEB)

    Itagaki, H.; Inomoto, M. [Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Asai, T.; Takahashi, Ts. [College of Science and Technology, Nihon University, 1-8-14 Kanda Surugadai, Chiyoda-ku, Tokyo 101-8308 (Japan)

    2014-03-15

    Active control of destructive rotational instability in a high-beta field-reversed configuration (FRC) plasma was demonstrated by using double-sided plasmoid injection technique. The elliptical deformation of the FRC's cross section was mitigated as a result of substantial suppression of spontaneous spin-up by the plasmoid injection. It was found that the injected plasmoid provided better stability against the rotational mode, suggesting that the compensation of the FRC's decaying magnetic flux might help to suppress its spin-up.

  19. Method of injecting cooling water in emergency core cooling system (ECCS) of PWR type reactor

    International Nuclear Information System (INIS)

    Sobajima, Makoto; Adachi, Michihiro; Tasaka, Kanji; Suzuki, Mitsuhiro.

    1979-01-01

    Purpose: To provide a cooling water injection method in an ECCS, which can perform effective cooling of the reactor core. Method: In a method of injecting cooling water in an ECCS as a countermeasure against a rupture accident of a pwr type reactor, cooling water in the first pressure storage injection system is injected into the upper plenum of the reactor pressure vessel at a set pressure of from 50 to 90 atg. and a set temperature of from 80 to 200 0 C, cooling water in the second pressure storage injection system is injected into the lower plenum of the reactor pressure vessel at a pressure of from 25 to 60 atg. which is lower than the set pressure and a temperature less than 60 0 C, and further in combination with these procedures, cooling water of less than 60 0 C is injected into a high-temperature side piping, in the high-pressure injection system of upstroke of 100 atg. by means of a pump and the low-pressure injection system of upstroke of 20 atg. also by means of a pump, thereby cooling the reactor core. (Aizawa, K.)

  20. Neutralizing SQL Injection Attack Using Server Side Code Modification in Web Applications

    Directory of Open Access Journals (Sweden)

    Asish Kumar Dalai

    2017-01-01

    Full Text Available Reports on web application security risks show that SQL injection is the top most vulnerability. The journey of static to dynamic web pages leads to the use of database in web applications. Due to the lack of secure coding techniques, SQL injection vulnerability prevails in a large set of web applications. A successful SQL injection attack imposes a serious threat to the database, web application, and the entire web server. In this article, the authors have proposed a novel method for prevention of SQL injection attack. The classification of SQL injection attacks has been done based on the methods used to exploit this vulnerability. The proposed method proves to be efficient in the context of its ability to prevent all types of SQL injection attacks. Some popular SQL injection attack tools and web application security datasets have been used to validate the model. The results obtained are promising with a high accuracy rate for detection of SQL injection attack.

  1. Price discrimination in two-sided markets

    Directory of Open Access Journals (Sweden)

    Kai Zhang

    2016-03-01

    Full Text Available The use of a price discrimination strategy is an important tool in competition. It can hurt firms and benefit consumers in a one-sided market. However, in two-sided markets, its primary goal is to attract more agents or increase profits. Here, the performance of a second-degree price discrimination strategy in the context of duopoly two-sided platforms is analysed. Two exogenous variables, which include the discount rate and the price discrimination threshold, are used in order to examine whether the price discrimination strategy could help two-sided platforms achieve their objective, which is to maximise their market value. Three cases are considered, and we demonstrate that the price discrimination strategy cannot attract more agents and at the same time increase the profits; a lower price discrimination threshold cannot ensure larger markets shares; a higher discount rate is detrimental to the profit of a platform. However, this is good for its market shares. Moreover, discriminative pricing increases the competition.

  2. Injection and accumulation method in the TARN

    International Nuclear Information System (INIS)

    Yamada, S.; Katayama, T.

    1979-03-01

    The test accumulation ring for NUMATRON (TARN) is being constructed at INS, University of Tokyo. The main purpose of the TARN is to establish some techniques related to beam injection and RF stacking, ultrahigh vacuum, and beam monitoring and handling. In this paper, the injection and accumulation methods in the TARN are described. The combination of multiturn injection and RF stacking is applied to the TARN. Heavy ions from the INS sector focusing (SF) cyclotron are injection through a magnetic and an electrostatic inflectors. Two pulse magnets and a bump field excited by square wave current are used for the multiturn injection method. The procedure of the RF stacking is as follows. The beam from the cyclotron is transported to the ring, and is injected by a multiturn method. Then, the RF accelerating voltage is put on, and the beam is captured in the stable region of the RF acceleration. The RF voltage and the frequency are adiabatically changed, and the beam is moved to the stacking orbit. The RF voltage is put off, and the beam remains on the stacking orbit. In the present system, a repetitive stacking scheme is applied for the RF stacking. The momentum spread after the RF stacking is approximately proportional to the stacking number in synchrotron phase space. The stacking number is chosen so that the total aperture required for the combined method may not exceed the available aperture in the ring doughnut. (Kato, T.)

  3. Improved radionuclide bone imaging agent injection needle withdrawal method can improve image quality

    International Nuclear Information System (INIS)

    Qin Yongmei; Wang Laihao; Zhao Lihua; Guo Xiaogang; Kong Qingfeng

    2009-01-01

    Objective: To investigate the improvement of radionuclide bone imaging agent injection needle withdrawal method on whole body bone scan image quality. Methods: Elbow vein injection syringe needle directly into the bone imaging agent in the routine group of 117 cases, with a cotton swab needle injection method for the rapid pull out the needle puncture point pressing, pressing moment. Improvement of 117 cases of needle injection method to put two needles into the skin swabs and blood vessels, pull out the needle while pressing two or more entry point 5min. After 2 hours underwent whole body bone SPECT imaging plane. Results: The conventional group at the injection site imaging agents uptake rate was 16.24%, improved group was 2.56%. Conclusion: The modified bone imaging agent injection needle withdrawal method, injection-site imaging agent uptake were significantly decreased whole body bone imaging can improve image quality. (authors)

  4. Simultaneous determination of two active components of pharmaceutical preparations by sequential injection method using heteropoly complexes

    Directory of Open Access Journals (Sweden)

    Mohammed Khair E. A. Al-Shwaiyat

    2014-12-01

    Full Text Available New approach has been proposed for the simultaneous determination of two reducing agents based on the dependence of their reaction rate with 18-molybdo-2-phosphate heteropoly complex on pH. The method was automated using the manifold typical for the sequential analysis method. Ascorbic acid and rutin were determined by successive injection of two samples acidified to different pH. The linear range for rutin determination was 0.6-20 mg/L and the detection limit was 0.2 mg/L (l = 1 cm. The determination of rutin was possible in the presence of up to a 20-fold excess of ascorbic acid. The method was successfully applied to the determination of ascorbic acid and rutin in ascorutin tablets. The applicability of the proposed method for the determination of total polyphenol content in natural plant samples was shown.

  5. Cardiovascular side effects of iopamidol, metrizamide, and amidotrizoate after intracoronary and left ventricular injections

    Energy Technology Data Exchange (ETDEWEB)

    Schraeder, R.; Wolpers, H.G.; Hoeft, A.; Korb, H.; Hellige, G.

    1984-05-01

    The acute cardiovascular side effects of iopamidol, metrizamide, and amidotrizoate during coronary arteriography and left ventriculography have been compared in anesthetized closed-chest dogs. The influence of these contrast media on hemodynamics, coronary circulation, ECG and physicochemical properties of coronary sinus blood were evaluated. Following intracoronary injection, iopamidol and metrizamide cause positive inotropism while amidotrizoate initially induces cardiodepression. All contrast solutions lead to marked increase of myocardial blood flow. Electrocardiographic changes are greater after amidotrizoate. A fall of cationic content in coronary sinus blood is seen after each contrast medium. Amidotrizoate leads to more decrease of potassium and both ionized and total calcium. Increase of osmolality and hydrogen ionic content is greater after amidotrizoate than after iopamidol and metrizamide. Following left ventricular injection, marked peripheral vasodilation, as seen after amidotrizoate, does not occur after low osmolality compounds. There are no significant differences between iopamidol and metrizamide in spite of the slightly higher osmolality of the former. Thus, both contrast materials should be equivalent with respect to their acute cardiovascular side effects under clinical conditions. Advantages of low osmolality radiological contrast media are discussed.

  6. The present state of research into plasma heating and injection methods

    International Nuclear Information System (INIS)

    1974-12-01

    The advantages and disadvantages recognized by the Advisory Group on Heating and injection for twelve plasma heating and injection methods currently under investigation in Europe are related. The heating and injection requirements of four reference reactor designs are previously defined. The problems which arise when one attempts to extrapolate existing work towards the reactor goal are emphasized. Two refuelling methods not directly linked with the heating problem are discussed. The experiments in operation or under construction in Europe in which each method is investigated are listed. Sixteen working papers which served as a basis for the Advisory Group discussion and which cover all the heating and injection methods examined are included

  7. Transport of nonintrinsic impurities injected by laser blow-off method

    International Nuclear Information System (INIS)

    Bakos, J.S.

    1993-09-01

    The transport of nonintrinsic impurities injected by laser blow-off method is theoretically described by solving the two-dimensional (radial and toroidal) time dependent equations of diffusion in the edge plasmas of a tokamak. Explicit expressions and evaluation procedures are given for the calculation of the density profile, temperature profile and the diffusion coefficients for the atoms injected and for the ions formed from the injected atoms from the two-dimensional intensity distribution of line radiation of two sorts of atom and ions formed from the atoms measured by a (matrix) CCD camera time resolved. (orig.)

  8. Financial methods for waterflooding injectate design

    Science.gov (United States)

    Heneman, Helmuth J.; Brady, Patrick V.

    2017-08-08

    A method of selecting an injectate for recovering liquid hydrocarbons from a reservoir includes designing a plurality of injectates, calculating a net present value of each injectate, and selecting a candidate injectate based on the net present value. For example, the candidate injectate may be selected to maximize the net present value of a waterflooding operation.

  9. Classification of gap flow regimes in two side-by-side circular cylinders

    CSIR Research Space (South Africa)

    Atkins, M

    2014-02-01

    Full Text Available The behavior of the flow around two circular cylinders arranged in a side-by-side configuration strongly depends on the transverse center-to-center gap spacing ratio (T/D) where D is the cylinder diameter. Based on the observed wake structure [13...

  10. Characterization of injection instabilities in electrohydrodynamics by numerical modelling: comparison of particle in cell and flux corrected transport methods for electroconvection between two plates

    International Nuclear Information System (INIS)

    Vazquez, P A; Georghiou, G E; Castellanos, A

    2006-01-01

    Numerical simulations are carried out for the characterization of injection instabilities in electrohydrodynamics and, in particular, the development of electroconvection between two parallel plates. The particle-in-cell and the finite element-flux corrected transport methods are used for the simulation of the test case, as they have proved very powerful and accurate in the solution of complex transport problems. Results are presented for unipolar injection (both strong and weak injections) between two plane electrodes immersed in a dielectric liquid, and the good agreement obtained by the two methods demonstrates not only their theoretical validity but also their practical ability to deal with transport problems in the presence of steep gradients. Some differences appear mainly in the prediction of small oscillations of the velocity and consequently of the electric current. These differences are highlighted and an explanation of their source is given

  11. Numerical study of two side-by-side cylinders with unequal diameters at low Reynolds number

    International Nuclear Information System (INIS)

    Gao, Y Y; Wang, X K; Tan, S K

    2012-01-01

    Two-dimensional laminar flow about two side-by-side unequal cylinders with different diameter ratios d/D and centre-to-centre spacing ratios T/D at Re=300 (based on the larger cylinder diameter) was simulated using a CFD software. Comparisons of experimental and numerical results were made to elucidate the degree of interference due to d/D and T/D and their effects on the flow patterns and vortex shedding frequencies. The findings showed that the flow patterns behind two unequal cylinders were distinctly different from that behind two equal side-by-side cylinders, with distinct in-phase and anti-phase vortex shedding, and random switching of modes of vortex shedding.

  12. Heat transfer from two-side heated helical channels

    International Nuclear Information System (INIS)

    Shimonis, V.; Ragaishis, V.; Poshkas, P.

    1995-01-01

    Experimental results are presented on the heat transfer from two-side heated helical channels to gas (air) flows. The study covered six configurations and wide ranges of geometrical (D/h=5.5 to 84.2) and performance (Re=10 3 to 2*10 5 ) parameters. Under the influence of Re and of the channel curvature, the heat transfer from both the convex and the concave surfaces for two-side heating (q w1 ≅ q w2 ) is augmented by 20-30% over one-side heating. Improved relations to predict the critical values of Reynolds Re cr1 and Re cr2 are suggested. They enable more exact predictions of the heat transfer from convex surface in transient flows for one-side heating. The relation for annular channels is suggested for the turbulent heat transfer from the convex and concave surfaces of two-side heated helical channels. It can be adapted by introducing earlier expresions for one-side heated helical channels. (author). 6 refs., 2 tabs., 3 figs

  13. Porous silicon formation by hole injection from a back side p+/n junction for electrical insulation applications

    International Nuclear Information System (INIS)

    Fèvre, A; Menard, S; Defforge, T; Gautier, G

    2016-01-01

    In this paper, we propose to study the formation of porous silicon (PS) in low doped (1 × 10 14 cm −3 ) n-type silicon through hole injection from a back side p + /n junction in the dark. This technique is investigated within the framework of electrical insulation. Three different types of junctions are investigated. The first one is an epitaxial n-type layer grown on p + doped silicon wafer. The two other junctions are carried out by boron diffusion leading to p + regions with junction depths of 20 and 115 μm. The resulting PS morphology is a double layer with a nucleation layer (NL) and macropores fully filled with mesoporous material. This result is unusual for low doped n-type silicon. Morphology variations are described depending on the junction formation process, the electrolyte composition, the anodization current density and duration. In order to validate the more interesting industrial potentialities of the p + /n injection technique, a comparison is achieved with back side illumination in terms of resulting morphology and experiments confirm comparable results. Electrical characterizations of the double layer, including NL and fully filled macropores, are then performed. To our knowledge, this is the first electrical investigation in low doped n type silicon with this morphology. Compared to the bulk silicon, the measured electrical resistivities are 6–7 orders of magnitude higher at 373 K. (paper)

  14. An Evaluation of One-Sided and Two-Sided Communication Paradigms on Relaxed-Ordering Interconnect

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Khaled Z. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hargrove, Paul H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Iancu, Costin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yelick, Katherine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-14

    The Cray Gemini interconnect hardware provides multiple transfer mechanisms and out-of-order message delivery to improve communication throughput. In this paper we quantify the performance of one-sided and two-sided communication paradigms with respect to: 1) the optimal available hardware transfer mechanism, 2) message ordering constraints, 3) per node and per core message concurrency. In addition to using Cray native communication APIs, we use UPC and MPI micro-benchmarks to capture one- and two-sided semantics respectively. Our results indicate that relaxing the message delivery order can improve performance up to 4.6x when compared with strict ordering. When hardware allows it, high-level one-sided programming models can already take advantage of message reordering. Enforcing the ordering semantics of two-sided communication comes with a performance penalty. Furthermore, we argue that exposing out-of-order delivery at the application level is required for the next-generation programming models. Any ordering constraints in the language specifications reduce communication performance for small messages and increase the number of active cores required for peak throughput.

  15. Multi-Criterion Two-Sided Matching of Public–Private Partnership Infrastructure Projects: Criteria and Methods

    Directory of Open Access Journals (Sweden)

    Ru Liang

    2018-04-01

    Full Text Available Two kinds of evaluative criteria are associated with Public–Private Partnership (PPP infrastructure projects, i.e., private evaluative criteria and public evaluative criteria. These evaluative criteria are inversely related, that is, the higher the public benefits; the lower the private surplus. To balance evaluative criteria in the Two-Sided Matching (TSM decision, this paper develops a quantitative matching decision model to select an optimal matching scheme for PPP infrastructure projects based on the Hesitant Fuzzy Set (HFS under unknown evaluative criterion weights. In the model, HFS is introduced to describe values of the evaluative criteria and multi-criterion information is fully considered given by groups. The optimal model is built and solved by maximizing the whole deviation of each criterion so that the evaluative criterion weights are determined objectively. Then, the match-degree of the two sides is calculated and a multi-objective optimization model is introduced to select an optimal matching scheme via a min-max approach. The results provide new insights and implications of the influence on evaluative criteria in the TSM decision.

  16. Two Crosslinking Technologies for Superficial Reticular Dermis Injection: A Comparative Ultrasound and Histologic Study

    OpenAIRE

    Micheels, Patrick; Besse, Stéphanie; Sarazin, Didier

    2017-01-01

    Background: Few hyaluronic acid fillers have been developed for superficial injection. Objective: To compare the diffusion and integration properties of cohesive polydensified matrix and Vycross® technology hyaluronic acid fillers with lidocaine following injection into the superficial reticular dermis. Methods and materials: Two subjects received two injections each of cohesive polydensified matrix and Vycross® hyaluronic acid (0.2mL/site) in the superficial reticular dermis of the buttock u...

  17. Fat Injection: A Systematic Review of Injection Volumes by Facial Subunit.

    Science.gov (United States)

    Shue, Shirley; Kurlander, David E; Guyuron, Bahman

    2017-08-08

    Fat grafting to the aging face has become an integral component of esthetic surgery. However, the amount of fat to inject to each area of the face is not standardized and has been based mainly on the surgeon's experience. The purpose of this study was to perform a systematic review of injected fat volume to different facial zones. A systematic review of the literature was performed through a MEDLINE search using keywords "facial," "fat grafting," "lipofilling," "Coleman technique," "autologous fat transfer," and "structural fat grafting." Articles were then sorted by facial subunit and analyzed for: author(s), year of publication, study design, sample size, donor site, fat preparation technique, average and range of volume injected, time to follow-up, percentage of volume retention, and complications. Descriptive statistics were performed. Nineteen articles involving a total of 510 patients were included. Rhytidectomy was the most common procedure performed concurrently with fat injection. The mean volume of fat injected to the forehead is 6.5 mL (range 4.0-10.0 mL); to the glabellar region 1.4 mL (range 1.0-4.0 mL); to the temple 5.9 mL per side (range 2.0-10.0 mL); to the eyebrow 5.5 mL per side; to the upper eyelid 1.7 mL per side (range 1.5-2.5 mL); to the tear trough 0.65 mL per side (range 0.3-1.0 mL); to the infraorbital area (infraorbital rim to lower lid/cheek junction) 1.4 mL per side (range 0.9-3.0 mL); to the midface 1.4 mL per side (range 1.0-4.0 mL); to the nasolabial fold 2.8 mL per side (range 1.0-7.5 mL); to the mandibular area 11.5 mL per side (range 4.0-27.0 mL); and to the chin 6.7 mL (range 1.0-20.0 mL). Data on exactly how much fat to inject to each area of the face in facial fat grafting are currently limited and vary widely based on different methods and anatomical terms used. This review offers the ranges and the averages for the injected volume in each zone. This journal requires that authors assign a level of evidence

  18. THE TWO SIDES OF MONEY LAUNDERING

    Directory of Open Access Journals (Sweden)

    Corina – Maria ENE

    2014-12-01

    Full Text Available The mainly goal of money laundering is to carry out more and more illegal economic transactions or activities to produce individual or groups gains and then to legitimate them. Money laundering converts illicit source of money generated by criminal activities in order to hide the connection between money and their original illegal activities. This is one of money laundering side. The second side implies corruption. While money laundering is a passing channel for illicit funds due to its criminal origin source, such funds may derive from corruption offences. All corruption’s forms represent the most important illicit funds branches for money laundering process. Corrupt people methods used to exploit the national and international financial system reflect the relationship between those two criminal activities. Criminals achieve their personal interests by hiding their corruption proceeds and transfer these gains to official economies. Corruption spread in any society entails money laundering spread, and the converse, too. There is a quite “indecent” relationship between money laundering and corruption. This paper tries to identify the multiple connections between the two phenomenons showing the negative impacts these criminal behaviours are having on the national and international economy. We conclude by highlighting the necessity of a multidisciplinary approach in order to fight against money laundering and corruption by integrating these problem frameworks at national level. International community must focus their resources on money laundering and corruption risks areas and maximize their response impact.

  19. A direct method for calculating instrument noise levels in side-by-side seismometer evaluations

    Science.gov (United States)

    Holcomb, L. Gary

    1989-01-01

    The subject of determining the inherent system noise levels present in modem broadband closed loop seismic sensors has been an evolving topic ever since closed loop systems became available. Closed loop systems are unique in that the system noise can not be determined via a blocked mass test as in older conventional open loop seismic sensors. Instead, most investigators have resorted to performing measurements on two or more systems operating in close proximity to one another and to analyzing the outputs of these systems with respect to one another to ascertain their relative noise levels.The analysis of side-by-side relative performance is inherently dependent on the accuracy of the mathematical modeling of the test configuration. This report presents a direct approach to extracting the system noise levels of two linear systems with a common coherent input signal. The mathematical solution to the problem is incredibly simple; however the practical application of the method encounters some difficulties. Examples of expected accuracies are presented as derived by simulating real systems performance using computer generated random noise. In addition, examples of the performance of the method when applied to real experimental test data are shown.

  20. A jaundiced bodybuilder Cholestatic hepatitis as side effect of injectable anabolic-androgenic steroids.

    Science.gov (United States)

    Boks, Marije N; Tiebosch, Anton T; van der Waaij, Laurens A

    2017-11-01

    The use of anabolic steroids is prevalent in recreational athletes. This case report describes a young amateur bodybuilder who was referred to our outpatient clinic with jaundice and loss of appetite due to cholestatic hepatitis. Additional tests including a liver biopsy made it likely that the hepatitis was caused by the injectable anabolic steroid trenbolone enanthate. Cholestatic hepatitis may not be limited to the use of oral anabolic-androgenic steroids, as is widely assumed. Therefore, and because of other side effects, the recreational use of all forms of anabolic steroids should be discouraged.

  1. Neutralizing SQL Injection Attack Using Server Side Code Modification in Web Applications

    OpenAIRE

    Dalai, Asish Kumar; Jena, Sanjay Kumar

    2017-01-01

    Reports on web application security risks show that SQL injection is the top most vulnerability. The journey of static to dynamic web pages leads to the use of database in web applications. Due to the lack of secure coding techniques, SQL injection vulnerability prevails in a large set of web applications. A successful SQL injection attack imposes a serious threat to the database, web application, and the entire web server. In this article, the authors have proposed a novel method for prevent...

  2. Studying intense pulsed light method along with corticosteroid injection in treating keloid scars.

    Science.gov (United States)

    Shamsi Meymandi, Simin; Rezazadeh, Azadeh; Ekhlasi, Ali

    2014-02-01

    Results of various studies suggest that the hypertrophic and keloid scars are highly prevalent in the general population and are irritating both physically and mentally. Considering the variety of existing therapies, intense pulsed light (IPL) method along with corticosteroid injection was evaluated in treating these scars. 86 subjects were included in this clinical trial. Eight sessions of therapeutic intervention were done with IPL along with corticosteroid intralesional injection using 450 to 1200 NM filter, Fluence 30-40 J/cm2, pulse duration of 2.1-10 ms and palsed delay 10-40 ms with an interval of three weeks. To specify the recovery consequences and complication rate and to determine features of the lesion, the criteria specified in the study of Eroll and Vancouver scar scale were used. The level of clinical improvement, color improvement and scar height was 89.1%, 88.8% and 89.1% respectively. The incidence of complications (1 telangiectasia case, 7 hyperpigmentation cases and 2 atrophy cases) following treatment with IPL was 11.6%. Moreover, the participants' satisfaction with IPL method was 88.8%. This study revealed that a combined therapy (intralesional corticosteroid injection + IPL) increases the recovery level of hypertrophic and keloid scars. It was also demonstrated that this method had no significant side effect and patients were highly satisfied with this method.

  3. Vortex interactions in a two side-by-side cylinder near-wake

    International Nuclear Information System (INIS)

    Wang, Z.J.; Zhou, Y.

    2005-01-01

    The flow behind two side-by-side circular cylinders is experimentally investigated based on laser-illuminated flow-visualization, particle image velocimetry and hot-wire measurements. The flow is classified as three regimes: single street (the cylinder center-to-center spacing T/d 2.0). Special attention is given to the regime of 1.2 2.0, the flow structure change from the anti-phase to in-phase mode starts with a phase shift between gap vortices. The dynamical role of gap bleeding between cylinders for L/d < 1.2 is also examined

  4. Left-sided gall bladder: Report of two cases

    Directory of Open Access Journals (Sweden)

    Chrungoo R

    2007-01-01

    Full Text Available Left-sided gall bladder without situs inversus viscerum is a rare albeit recognized clinical entity. We report our experience of two cases of left-sided gall bladder in two women aged 36 and 48 who underwent laparoscopic cholecystectomy for chronic calculous cholecystitis. Left-sided gall bladder may provide an unusual surprise to the surgeons during laparoscopy as routine pre-operative studies may not always detect the anomaly. Awareness of the unpredictable confluence of the cystic duct into the common bile duct (CBD and selective use of intraoperative cholangiography aid in the safe laparoscopic management of this unusual entity.

  5. Bond strength of two component injection moulded MID

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2006-01-01

    Most products of the future will require industrially adapted, cost effective production processes and on this issue two-component (2K) injection moulding is a potential candidate for MID manufacturing. MID based on 2k injection moulded plastic part with selectively metallised circuit tracks allows...... the two different plastic materials in the MID structure require good bonding between them. This paper finds suitable combinations of materials for MIDs from both bond strength and metallisation view-point. Plastic parts were made by two-shot injection moulding and the effects of some important process...... the integration of electrical and mechanical functionalities in a real 3D structure. If 2k injection moulding is applied with two polymers, of which one is plateable and the other is not, it will be possible to make 3D electrical structures directly on the component. To be applicable in the real engineering field...

  6. The two sides of silicon detectors

    International Nuclear Information System (INIS)

    Devine, S.R.

    2001-10-01

    Results are presented on in situ irradiation of silicon detector's at cryogenic temperature. The results show that irradiation at cryogenic temperatures does not detrimentally effect a silicon detectors performance when compared to its irradiation at room temperature. Operation of silicon devices at cryogenic temperatures offers the advantage of reducing radiation-induced leakage current to levels of a few pA, while at 130K the Lazarus Effect plays an important role i.e. minimum voltage required for full depletion. Performing voltage scans on a 'standard' silicon pad detector pre- and post annealing, the charge collection efficiency was found to be 60% at 200V and 95% at 200V respectively. Time dependence measurements are presented, showing that for a dose of 6.5x10 14 p/cm 2 (450GeV protons) the time dependence of the charge collection efficiency is negligible. However, for higher doses, 1.2x10 15 p/cm 2 , the charge collection efficiency drops from an initial measured value of 67% to a stable value of 58% over a period of 15 minutes for reversed biased diodes. An analysis of the 'double junction' effect is also presented. A comparison between the Transient Current Technique and an X-ray technique is presented. The double junction has been observed in p + /n/n + silicon detectors after irradiation beyond 'type inversion', corresponding to a fluence equivalent to ∼3x10 13 cm -2 1MeV neutrons, producing p + /p/n + and essentially two p-n junctions within one device. With increasing bias voltage, as the electric field is extending into the detector bulk from opposite sides of the silicon detector, there are two distinct depletion regions that collect charge signal independently. Summing the signal charge from the two regions, one is able to reconstruct the initial energy of the incident particle. From Transient Current measurements it is apparent that E-field manipulation is possible by excess carrier injection, enabling a high enough E-field to extend across the

  7. Two injection digital block versus single subcutaneous palmar injection block for finger lacerations.

    Science.gov (United States)

    Okur, O M; Şener, A; Kavakli, H Ş; Çelik, G K; Doğan, N Ö; Içme, F; Günaydin, G P

    2017-12-01

    We aimed to compare two digital nerve block techniques in patients due to traumatic digital lacerations. This was a randomized-controlled study designed prospectively in the emergency department of a university-based training and research hospital. Randomization was achieved by sealed envelopes. Half of the patients were randomised to traditional (two-injection) digital nerve block technique while single-injection digital nerve block technique was applied to the other half. Score of pain due to anesthetic infiltration and suturing, onset time of total anesthesia, need for an additional rescue injection were the parameters evaluated with both groups. Epinephrin added lidocaine hydrochloride preparation was used for the anesthetic application. Visual analog scale was used for the evaluation of pain scores. Outcomes were compared by using Mann-Whitney U test and Student t-test. Fifty emergency department patients ≥18 years requiring digital nerve block were enrolled in the study. Mean age of the patients was 33 (min-max: 19-86) and 39 (78 %) were male. No statistically significant difference was found between the two groups in terms of our main parameters; anesthesia pain score, suturing pain score, onset time of total anesthesia and rescue injection need. Single injection volar digital nerve block technique is a suitable alternative for digital anesthesias in emergency departments.

  8. Successive Two-sided Loop Jets Caused by Magnetic Reconnection between Two Adjacent Filamentary Threads

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Zhanjun; Liu, Yu; Shen, Yuandeng [Yunnan Observatories, Chinese Academy of Sciences, Kunming, 650216 (China); Elmhamdi, Abouazza; Kordi, Ayman S. [Department of Physics and Astronomy, King Saud University, P.O. Box 2455, 11451 (Saudi Arabia); Su, Jiangtao [University of Chinese Academy of Sciences, Beijing 100049 (China); Liu, Ying D., E-mail: ydshen@ynao.ac.cn [State Key Laboratory of Space Weather, Chinese Academy of Sciences, Beijing 100190 (China)

    2017-08-20

    We present observational analysis of two successive two-sided loop jets observed by the ground-based New Vacuum Solar Telescope and the space-borne Solar Dynamics Observatory . The two successive two-sided loop jets manifested similar evolution processes and both were associated with the interaction of two small-scale adjacent filamentary threads, magnetic emerging, and cancellation processes at the jet’s source region. High temporal and high spatial resolution observations reveal that the two adjacent ends of the two filamentary threads are rooted in opposite magnetic polarities within the source region. The two threads approached each other, and then an obvious brightening patch is observed at the interaction position. Subsequently, a pair of hot plasma ejections are observed heading in opposite directions along the paths of the two filamentary threads at a typical speed for two-sided loop jets of the order 150 km s{sup −1}. Close to the end of the second jet, we report the formation of a bright hot loop structure at the source region, which suggests the formation of new loops during the interaction. Based on the observational results, we propose that the observed two-sided loop jets are caused by magnetic reconnection between the two adjacent filamentary threads, largely different from the previous scenario that a two-sided loop jet is generated by magnetic reconnection between an emerging bipole and the overlying horizontal magnetic fields.

  9. Improvement of Power Flow Calculation with Optimization Factor Based on Current Injection Method

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2014-01-01

    Full Text Available This paper presents an improvement in power flow calculation based on current injection method by introducing optimization factor. In the method proposed by this paper, the PQ buses are represented by current mismatches while the PV buses are represented by power mismatches. It is different from the representations in conventional current injection power flow equations. By using the combined power and current injection mismatches method, the number of the equations required can be decreased to only one for each PV bus. The optimization factor is used to improve the iteration process and to ensure the effectiveness of the improved method proposed when the system is ill-conditioned. To verify the effectiveness of the method, the IEEE test systems are tested by conventional current injection method and the improved method proposed separately. Then the results are compared. The comparisons show that the optimization factor improves the convergence character effectively, especially that when the system is at high loading level and R/X ratio, the iteration number is one or two times less than the conventional current injection method. When the overloading condition of the system is serious, the iteration number in this paper appears 4 times less than the conventional current injection method.

  10. Structural and electronic properties of free standing one-sided and two-sided hydrogenated silicene: A first principle study

    International Nuclear Information System (INIS)

    Mohan, Brij; Kumar, Ashok; Ahluwalia, P. K.

    2014-01-01

    We performed first-principle study of the structural and electronic properties of two-dimensional hydrogenated silicene for two configurations; one is hydrogenation along one side of silicene sheet and second is hydrogenation in both sides of silicene sheet. The one-side hydrogenated silicene is found stable at planar geometry while increased buckling of 0.725 Å is found for both-side hydrogenated silicene. The result shows that the hydrogenation occupy the extended π-bonding network of silicene, and thus it exhibits semi-conducting behaviour with a band gap of 1.77 eV and 2.19 eV for one-side hydrogenated silicene and both-side hydrogenated silicene respectively. However, both-side hydrogenated silicene of binding energy 4.56 eV is more stable than one-side hydrogenated silicene of binding energy 4.30 eV, but experimentally silicene is synthesized on substrates which interacts one side of silicene layer and only other side is available for H-atoms. Therefore, practically one-side hydrogenation is also important

  11. Light extinction method on high-pressure diesel injection

    Science.gov (United States)

    Su, Tzay-Fa; El-Beshbeeshy, Mahmound S.; Corradini, Michael L.; Farrell, Patrick V.

    1995-09-01

    A two dimensional optical diagnostic technique based on light extinction was improved and demonstrated in an investigation of diesel spray characteristics at high injection pressures. Traditional light extinction methods require the spray image to be perpendicular to the light path. In the improved light extinction scheme, a tilted spray image which has an angle with the light path is still capable of being processed. This technique utilizes high speed photography and digital image analysis to obtain qualitative and quantitative information of the spray characteristics. The injection system used was an electronically controlled common rail unit injector system with injection pressures up to 100 MPa. The nozzle of the injector was a mini-sac type with six holes on the nozzle tip. Two different injection angle nozzles, 125 degree(s) and 140 degree(s), producing an in-plane tilted spray and an out of plane tilted spray were investigated. The experiments were conducted on a constant volume spray chamber with the injector mounted tilted at an angle of 62.5 degree(s)$. Only one spray plume was viewed, and other sprays were free to inject to the chamber. The spray chamber was pressurized with argon and air under room temperature to match the combustion chamber density at the start of the injection. The experimental results show that the difference in the spray tip penetration length, spray angle, and overall average Sauter mean diameter is small between the in- plane tilted spray and the out of plane tilted spray. The results also show that in-plane tilted spray has a slightly larger axial cross- section Sauter mean diameter than the out of plane tilted spray.

  12. Dual-sided reading versus single-sided reading: comparison of image quality and radiation dose between the two computed radiography system

    International Nuclear Information System (INIS)

    Song Shaojuan; Qi Hengtao; Zhao Yongxia; Jiao Fanglian

    2007-01-01

    Objective: To assess and compare the difference in image quality and exposure dose between single-sided reading image plate (IP) and dual-sided reading IP. Methods: A contrast-detail phantom CDRAD 2.0 was exposed by single-sided and dual-sided reading IP with different mAs sets. The entrance surface doses were recorded for all images. Images were then presented to two radiologists on a high resolution monitor of diagnosis workstation. The image quality figure (IQF) was measured for each image. Statistical analysis was performed using Spearman's correlation test and Wilcoxon signed-rank test to compare the difference in image quality and exposure dose between single-sided IP and dual-sided reading IP. Results: With different tube current dosage of 5.6, 12.0, 20.0, 25.0, and 40.0 mAs, IQF values of single-sided reading IP were 47.95, 37.68, 34.31, 28.61, and 24.65, respectively, while those of dual- sided reading IP were 38.83, 29.81, 29.65, 25.16, and 21.43, respectively. The IQF difference between them showed statistical significance (P<0.05). Conclusion: Image quality of dual-sided reading IP has been proved to be far superior to that of single-sided reading IP, in particular for low contrast detail. The image quality of single-sided reading IP is similar to that of dual-sided reading IP only at high dose levels. The clinical application of dual-sided reading IP will reduce the exposure dose by about 25% compared with single-sided reading IP. (authors)

  13. High-speed pellet injection with a two-stage pneumatic gun

    International Nuclear Information System (INIS)

    Reggiori, A.; Carlevaro, R.; Riva, G.; Daminelli, G.B.; Scaramuzzi, F.; Frattolillo, A.; Martinis, L.; Cardoni, P.; Mori, L.

    1988-01-01

    The injection of pellets of frozen hydrogen isotopes into fusion plasmas is envisioned as a fueling technique for future fusion reactors. Research is underway to obtain high injection speeds for solid H 2 and D 2 pellets. The optimization of a two-stage light gas gun is being pursued by the Milano group; the search for a convenient method of creating pellets with good mechanical properties and a secure attachment to the cold surface on which they are formed is carried out in Frascati. Velocities >2000 m/s have been obtained, but reproducibility is not yet satisfactory

  14. Foam injection method and system

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, W C; Parmley, J B; Shepard, J C

    1977-05-10

    A method is described for more efficiently practicing in situ combustion techniques by generating a gas-water mist or foam adjacent to the combustion formation within the injection well. The mist or foam is forced out of the well into the formation to transport heat away from the burned region of the formation toward the periphery of the combustion region to conserve fuel. Also taught are a method and system for fluid treating a formation while maintaining enhanced conformance of the fluid injection profile by generating a mist or foam down-hole adjacent to the formation and then forcing the mist or foam out into the formation. (19 claims)

  15. Scheduling Two-Sided Transformations Using Tile Algorithms on Multicore Architectures

    Directory of Open Access Journals (Sweden)

    Hatem Ltaief

    2010-01-01

    Full Text Available The objective of this paper is to describe, in the context of multicore architectures, three different scheduler implementations for the two-sided linear algebra transformations, in particular the Hessenberg and Bidiagonal reductions which are the first steps for the standard eigenvalue problems and the singular value decompositions respectively. State-of-the-art dense linear algebra softwares, such as the LAPACK and ScaLAPACK libraries, suffer performance losses on multicore processors due to their inability to fully exploit thread-level parallelism. At the same time the fine-grain dataflow model gains popularity as a paradigm for programming multicore architectures. Buttari et al. (Parellel Comput. Syst. Appl. 35 (2009, 38–53 introduced the concept of tile algorithms in which parallelism is no longer hidden inside Basic Linear Algebra Subprograms but is brought to the fore to yield much better performance. Along with efficient scheduling mechanisms for data-driven execution, these tile two-sided reductions achieve high performance computing by reaching up to 75% of the DGEMM peak on a 12000×12000 matrix with 16 Intel Tigerton 2.4 GHz processors. The main drawback of the tile algorithms approach for two-sided transformations is that the full reduction cannot be obtained in one stage. Other methods have to be considered to further reduce the band matrices to the required forms.

  16. Control of Surge in Centrifugal Compressor by Using a Nozzle Injection System: Universality in Optimal Position of Injection Nozzle

    Directory of Open Access Journals (Sweden)

    Toshiyuki Hirano

    2012-01-01

    Full Text Available The passive control method for surge and rotating stall in centrifugal compressors by using a nozzle injection system was proposed to extend the stable operating range to the low flow rate. A part of the flow at the scroll outlet of a compressor was recirculated to an injection nozzle installed on the inner wall of the suction pipe of the compressor through the bypass pipe and injected to the impeller inlet. Two types of compressors were tested at the rotational speeds of 50,000 rpm and 60,000 rpm with the parameter of the circumferential position of the injection nozzle. The present experimental results revealed that the optimum circumferential position, which most effectively reduced the flow rate for the surge inception, existed at the opposite side of the tongue of the scroll against the rotational axis and did not depend on the compressor system and the rotational speeds.

  17. Price Competition in Two-Sided Markets with Heterogeneous Consumers and Network Effects

    NARCIS (Netherlands)

    Filistrucchi, L.; Klein, T.J.

    We model a two-sided market with heterogeneous customers and two heterogeneous network effects. In our model, customers on each market side care differently about both the number and the type of customers on the other side. Examples of two-sided markets are online platforms or daily newspapers. In

  18. Dependability validation by means of fault injection: method, implementation, application

    International Nuclear Information System (INIS)

    Arlat, Jean

    1990-01-01

    This dissertation presents theoretical and practical results concerning the use of fault injection as a means for testing fault tolerance in the framework of the experimental dependability validation of computer systems. The dissertation first presents the state-of-the-art of published work on fault injection, encompassing both hardware (fault simulation, physical fault Injection) and software (mutation testing) issues. Next, the major attributes of fault injection (faults and their activation, experimental readouts and measures, are characterized taking into account: i) the abstraction levels used to represent the system during the various phases of its development (analytical, empirical and physical models), and Il) the validation objectives (verification and evaluation). An evaluation method is subsequently proposed that combines the analytical modeling approaches (Monte Carlo Simulations, closed-form expressions. Markov chains) used for the representation of the fault occurrence process and the experimental fault Injection approaches (fault Simulation and physical injection); characterizing the error processing and fault treatment provided by the fault tolerance mechanisms. An experimental tool - MESSALINE - is then defined and presented. This tool enables physical faults to be Injected In an hardware and software prototype of the system to be validated. Finally, the application of MESSALINE for testing two fault-tolerant systems possessing very dissimilar features and the utilization of the experimental results obtained - both as design feedbacks and for dependability measures evaluation - are used to illustrate the relevance of the method. (author) [fr

  19. Non-Liouvillean ion injection via resonantly enhanced two-photon ionization

    Directory of Open Access Journals (Sweden)

    B. A. Knyazev

    2004-03-01

    Full Text Available The charge-exchange method is now one of the main techniques for ion injection into accelerators and storage rings. The disadvantages of conventional methods, based on the atom or ion stripping in a material target, are emittance growth, energy straggling, and production of ions in many charge states. Recently suggested stripping methods based on direct photoionization require employment of hard-UV lasers, which still do not exist and must obviously be very bulky and expensive. An alternative method, suggested for injection of proton beams, employs excitation of the atom to 3p intermediate state with subsequent Lorentz ionization in a magnetic field gradient. This technique applies rigid requirements to laser characteristic and is not free of growing of the beam divergence. In this paper a variant of the stripping technique based on the resonantly enhanced two-photon ionization (RETPI is considered. The technique allows ionization of singly charged ions of the elements from helium to bismuth. A variant of the technique can be used for proton injection. RETPI can be applied for both ion injection and stacking, as well as for diagnostics of ion beam characteristics on the orbit. Stripping efficiency can be about 100% for the singly charged ions having the singlet ground state and decreases for the other ions. Special methods for “cleaning” unwanted atomic states in such ions, that can provide high stripping efficiency, are discussed. Excimer lasers with very moderate parameters can be employed for implementation of this technique for almost all elements. Numerical examples show that for most of the singly charged ions and for hydrogen atom necessary laser-beam energy density is merely 0.5–8  J/cm^{2} for a 1 m interaction region, and is 10 times higher for several light ions.

  20. Does Injection of Lidocaine with 1/100000 Epinephrine Immediately before Lateral Osteotomy Reduce Post-Operative Periorbital Edema and Ecchymosis in Rhinoplasty?

    Directory of Open Access Journals (Sweden)

    mansoor zojajy

    2014-06-01

    Full Text Available Background: Postoperative periorbital edema and ecchymosis are common after rhinoplasty. We studied the effect of local injection of Lidocaine/Adrenaline immediately before osteotomy on prevention of post-operative periorbital edema and ecchymosis in rhinoplasty.Materials and Methods: Thirty healthy candidates for rhinoplasty were enrolled in the self-controlled clinical trial study. Lidocaine/Adrenaline solution injected randomly to one side just prior to the lateral osteotomy. The opposite side used as a control. The degree of edema/ecchymosis on both sides was compared on the 1st, 2nd and 7th day postoperatively.Results: Mean of severity of edema, 24 hours after operation was 3in both sides, (Mann-whitney U; p=0.829. Mean of severity of edema, 48 hours after operation was 2 in both sides (Mann-whitney U; p=0.867 and it was 1 in both sides 7 days after operation (Mann-whitney U; p=0.756.There was no significant difference between two sides. Mean of severity of ecchymosis, 24 hours after operation was 3 in both sides (Mann-whitney U; p=0.692. Mean of severity of ecchymosis, 48 hours after operation was 2 in both sides (Mann-whitney U; p=0.655 and it was 1 in both sides 7 days after operation (Mann-whitney U; p=0.873. There was no significant difference between two sides.Conclusion: local injection of Lidocaine/Adrenaline solution immediately before lateral osteotomy could not reduce postoperative edema and ecchymosis in rhinoplasty.

  1. Thickness measurement by two-sided step-heating thermal imaging

    Science.gov (United States)

    Li, Xiaoli; Tao, Ning; Sun, J. G.; Zhang, Cunlin; Zhao, Yuejin

    2018-01-01

    Infrared thermal imaging is a promising nondestructive technique for thickness prediction. However, it is usually thought to be only appropriate for testing the thickness of thin objects or near-surface structures. In this study, we present a new two-sided step-heating thermal imaging method which employed a low-cost portable halogen lamp as the heating source and verified it with two stainless steel step wedges with thicknesses ranging from 5 mm to 24 mm. We first derived the one-dimensional step-heating thermography theory with the consideration of warm-up time of the lamp, and then applied the nonlinear regression method to fit the experimental data by the derived function to determine the thickness. After evaluating the reliability and accuracy of the experimental results, we concluded that this method is capable of testing thick objects. In addition, we provided the criterions for both the required data length and the applicable thickness range of the testing material. It is evident that this method will broaden the thermal imaging application for thickness measurement.

  2. Side branch absorber for exhaust manifold of two-stroke internal combustion engine

    Science.gov (United States)

    Harris, Ralph E [San Antonio, TX; Broerman, III, Eugene L.; Bourn, Gary D [Laramie, WY

    2011-01-11

    A method of improving scavenging operation of a two-stroke internal combustion engine. The exhaust pressure of the engine is analyzed to determine if there is a pulsation frequency. Acoustic modeling is used to design an absorber. An appropriately designed side branch absorber may be attached to the exhaust manifold.

  3. Validation of DRAGON side-step method for Bruce-A restart Phase-B physics tests

    International Nuclear Information System (INIS)

    Shen, W.; Ngo-Trong, C.; Davis, R.S.

    2004-01-01

    The DRAGON side-step method, developed at AECL, has a number of advantages over the all-DRAGON method that was used before. It is now the qualified method for reactivity-device calculations. Although the side-step-method-generated incremental cross sections have been validated against those previously calculated with the all-DRAGON method, it is highly desirable to validate the side-step method against device-worth measurements in power reactors directly. In this paper, the DRAGON side-step method was validated by comparison with the device-calibration measurements made in Bruce-A NGS Unit 4 restart Phase-B commissioning in 2003. The validation exercise showed excellent results, with the DRAGON code overestimating the measured ZCR worth by ∼5%. A sensitivity study was also performed in this paper to assess the effect of various DRAGON modelling techniques on the incremental cross sections. The assessment shows that the refinement of meshes in 3-D and the use of the side-step method are two major reasons contributing to the improved agreement between the calculated ZCR worths and the measurements. Use of different DRAGON versions, DRAGON libraries, local-parameter core conditions, and weighting techniques for the homogenization of tube clusters inside the ZCR have a very small effect on the ZCR incremental thermal absorption cross section and ZCR reactivity worth. (author)

  4. Two sides of a fault: Grain-scale analysis of pore pressure control on fault slip.

    Science.gov (United States)

    Yang, Zhibing; Juanes, Ruben

    2018-02-01

    Pore fluid pressure in a fault zone can be altered by natural processes (e.g., mineral dehydration and thermal pressurization) and industrial operations involving subsurface fluid injection and extraction for the development of energy and water resources. However, the effect of pore pressure change on the stability and slip motion of a preexisting geologic fault remains poorly understood; yet, it is critical for the assessment of seismic hazard. Here, we develop a micromechanical model to investigate the effect of pore pressure on fault slip behavior. The model couples fluid flow on the network of pores with mechanical deformation of the skeleton of solid grains. Pore fluid exerts pressure force onto the grains, the motion of which is solved using the discrete element method. We conceptualize the fault zone as a gouge layer sandwiched between two blocks. We study fault stability in the presence of a pressure discontinuity across the gouge layer and compare it with the case of continuous (homogeneous) pore pressure. We focus on the onset of shear failure in the gouge layer and reproduce conditions where the failure plane is parallel to the fault. We show that when the pressure is discontinuous across the fault, the onset of slip occurs on the side with the higher pore pressure, and that this onset is controlled by the maximum pressure on both sides of the fault. The results shed new light on the use of the effective stress principle and the Coulomb failure criterion in evaluating the stability of a complex fault zone.

  5. Two sides of a fault: Grain-scale analysis of pore pressure control on fault slip

    Science.gov (United States)

    Yang, Zhibing; Juanes, Ruben

    2018-02-01

    Pore fluid pressure in a fault zone can be altered by natural processes (e.g., mineral dehydration and thermal pressurization) and industrial operations involving subsurface fluid injection and extraction for the development of energy and water resources. However, the effect of pore pressure change on the stability and slip motion of a preexisting geologic fault remains poorly understood; yet, it is critical for the assessment of seismic hazard. Here, we develop a micromechanical model to investigate the effect of pore pressure on fault slip behavior. The model couples fluid flow on the network of pores with mechanical deformation of the skeleton of solid grains. Pore fluid exerts pressure force onto the grains, the motion of which is solved using the discrete element method. We conceptualize the fault zone as a gouge layer sandwiched between two blocks. We study fault stability in the presence of a pressure discontinuity across the gouge layer and compare it with the case of continuous (homogeneous) pore pressure. We focus on the onset of shear failure in the gouge layer and reproduce conditions where the failure plane is parallel to the fault. We show that when the pressure is discontinuous across the fault, the onset of slip occurs on the side with the higher pore pressure, and that this onset is controlled by the maximum pressure on both sides of the fault. The results shed new light on the use of the effective stress principle and the Coulomb failure criterion in evaluating the stability of a complex fault zone.

  6. Upward Pricing Pressure in Two-Sided Markets

    NARCIS (Netherlands)

    Affeldt, P.; Filistrucchi, L.; Klein, T.J.

    2012-01-01

    Abstract: Pricing pressure indices have recently been proposed as alternative screening devices for horizontal mergers involving differentiated products. We extend the concept of Upward Pricing Pressure (UPP) proposed by Farrell and Shapiro (2010) to two-sided markets. Examples of such markets are

  7. Radiation pressure injection in laser-wakefield acceleration

    Science.gov (United States)

    Liu, Y. L.; Kuramitsu, Y.; Isayama, S.; Chen, S. H.

    2018-01-01

    We investigated the injection of electrons in laser-wakefield acceleration induced by a self-modulated laser pulse by a two dimensional particle-in-cell simulation. The localized electric fields and magnetic fields are excited by the counter-streaming flows on the surface of the ion bubble, owing to the Weibel or two stream like instability. The electrons are injected into the ion bubble from the sides of it and then accelerated by the wakefield. Contrary to the conventional wave breaking model, the injection of monoenergetic electrons are mainly caused by the electromagnetic process. A simple model was proposed to address the instability, and the growth rate was verified numerically and theoretically.

  8. [Application of lymph node labeling with carbon nanoparticles by preoperative endoscopic subserosal injection in laparoscopic radical gastrectomy].

    Science.gov (United States)

    Hong, Q; Wang, Y; Wang, J J; Hu, C G; Fang, Y J; Fan, X X; Liu, T; Tong, Q

    2017-01-10

    Objective: To evaluate the application value of carbon lymph node tracing technique by preoperative endoscopic subserosal injection in laparoscopic radical gastrectomy. Methods: From June 2013 to February 2015, seventy eight patients with gastric cancer were enrolled and randomly divided into trial group and control group. Subserosal injection of carbon nanoparticles around the tumor was performed by preoperative endoscopic subserosal injection one day before the operation in trial group, while the patients routinely underwent laparoscopic gastrectomy in control group. Results of harvested lymph nodes, postoperative complications were compared between the two groups. Carbon nanoparticle-related side effect was also evaluated. Results: The average number of harvested lymph node in trial group was significantly higher than that in control group (35.5±8.5 vs 29.5±6.5, P 0.05), and no carbon nanoparticle-related side effect was observed. Conclusion: Given a higher harvested lymph node number and a similar rate of complications, preoperative endoscopic subserosal injection of carbon nanoparticles was safe and feasible.

  9. Children's behavioral pain reactions during local anesthetic injection using cotton-roll vibration method compared with routine topical anesthesia: A randomized controlled trial.

    Science.gov (United States)

    Bagherian, Ali; Sheikhfathollahi, Mahmood

    2016-01-01

    Topical anesthesia has been widely advocated as an important component of atraumatic administration of intraoral local anesthesia. The aim of this study was to use direct observation of children's behavioral pain reactions during local anesthetic injection using cotton-roll vibration method compared with routine topical anesthesia. Forty-eight children participated in this randomized controlled clinical trial. They received two separate inferior alveolar nerve block or primary maxillary molar infiltration injections on contralateral sides of the jaws by both cotton-roll vibration (a combination of topical anesthesia gel, cotton roll, and vibration for physical distraction) and control (routine topical anesthesia) methods. Behavioral pain reactions of children were measured according to the author-developed face, head, foot, hand, trunk, and cry (FHFHTC) scale, resulting in total scores between 0 and 18. The total scores on the FHFHTC scale ranged between 0-5 and 0-10 in the cotton-roll vibration and control methods, respectively. The mean ± standard deviation values of total scores on FHFHTC scale were lower in the cotton-roll vibration method (1.21 ± 1.38) than in control method (2.44 ± 2.18), and this was statistically significant (P anesthesia in reducing behavioral pain reactions in children during local anesthesia administration.

  10. Launching a Two-sided Platform

    OpenAIRE

    Solheim, Magnus Tovsen; Tovsen, Ole Kristoffer Solheim

    2017-01-01

    Two-sided platforms, such as Airbnb, Uber and eBay, have all revolutionized their industries. Despite having colossal potential, they are very difficult to launch. This is due to what s referred to as network effects, which imply that the value of the platform becomes larger as more people use it. Network effects lead to a chicken-or-egg-problem , where it is difficult to convince sellers to join if there are no buyers and vice versa, in addition to the need to reach a critical mass of users...

  11. Promotion of cooperation induced by two-sided players in prisoner's dilemma game

    Science.gov (United States)

    Su, Zhen; Li, Lixiang; Xiao, Jinghua; Podobnik, B.; Stanley, H. Eugene

    2018-01-01

    We examine how real-world individuals and companies can either reach an agreement or fail to reach an agreement after several stages of negotiation. We use a modified prisoner's dilemma game with two-sided players who can either cooperate or not cooperate with their neighbors. We find that the presence of even a small number of these two-sided players substantially promotes the cooperation because, unlike the rock-paper-scissors scenario, when the cooperators change to the non-cooperators to gain a payoff, they can turn to the two-sided players and continue negotiating. We find that the network structure influences the spread of strategies. Lattice and regular-random (RR) networks benefit the spread of both non-cooperation and two-sided strategies, but scale-free (SF) networks stop both strategies. We also find that the Erdös-R e ´ nyi (ER) network promotes the two-sided strategy and blocks the spread of non-cooperation. As the ER network density decreases, and the network degree is lowered the lifetime of non-cooperators increases. Our results expand our understanding of the role played by the two-sided strategy in the growth of the cooperative behavior in networks.

  12. Minimum-Voltage Vector Injection Method for Sensorless Control of PMSM for Low-Speed Operations

    DEFF Research Database (Denmark)

    Xie, Ge; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2016-01-01

    In this paper, a simple signal injection method is proposed for sensorless control of PMSM at low speed, which ideally requires one voltage vector only for position estimation. The proposed method is easy to implement resulting in low computation burden. No filters are needed for extracting...... may also be further developed to inject two opposite voltage vectors to reduce the effects of inverter voltage error on the position estimation accuracy. The effectiveness of the proposed method is demonstrated by comparing with other sensorless control method. Theoretical analysis and experimental...

  13. Impacts of pellets injected from the low-field side on plasma in ITER

    International Nuclear Information System (INIS)

    Wisitsorasak, A.; Onjun, T.

    2011-01-01

    Impacts of pellets injected from the low-field side (LFS) on plasma in ITER are investigated using the 1.5D BALDUR integrated predictive modeling code. In these simulations, the pellet ablation is described using the neutral gas shielding (NGS) model. The pellet ablation model is coupled with the plasma core transport model, which is a combination of the MMM95 anomalous transport model and NCLASS neoclassical transport model. The boundary conditions are assumed to be at the top of the pedestal, in which the pedestal parameters are predicted using a pedestal model based on the theoretical-based pedestal width scaling (either magnetic and flow shear stabilization width scaling, or flow shear stabilization width scaling, or normalized poloidal pressure width scaling) and the infinite-n ballooning mode pressure gradient limit. These pedestal models depend sensitively on the density at the top of the pedestal, which can be strongly influenced by the injection of pellets. The combination of the MMM95 and NCLASS models, together with the pedestal and NGS models, is used to simulate the time evolution of the plasma current, ion and electron temperatures, and density profiles for ITER standard type-I ELMy H-mode discharges during the injection of LFS pellets. It is found that the injection of pellets results in a complicated plasma scenario, especially in the outer region of the plasma and the plasma conditions at the boundary in which the pellet has an impact on increasing the plasma edge density, but reducing the plasma edge temperature. The LFS pellet has a stronger impact on the edge as compared to the center. For fusion performance, the pellet can result in either enhancement or degradation, depending sensitively on the pellet parameters; such as the pellet size, pellet velocity, and pellet frequency. For example, when a series of deuterium pellets with a size of 0.5 cm, velocity of 1 km/s, and frequency of 2 Hz are injected into the ITER plasma from the LFS, the

  14. Spread of Injectate Around Hip Articular Sensory Branches of the Femoral Nerve in Cadavers

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Greher, Manfred; Moriggl, Bernhard

    2018-01-01

    of the femoral nerve. Methods: Fifteen cadaver sides were injected with 5 mL dye in the iliopsoas plane guided by ultrasound. Dissection was performed to verify the spread of injectate around the hip articular branches of the femoral nerve. Results: In 10 dissections (67% [95% confidence interval: 38.......2-32%]) adhesions partially obstructed the spread of dye. Conclusion: An injection of 5 mL in the iliopsoas plane spreads around all hip articular branches of the femoral nerve in 10 of 15 cadaver sides. If these findings translate to living humans, injection of local anaesthetic into the iliopsoas plane could...

  15. Assessing unilateral merger effects in a two-sided market : An application to the Dutch daily newspaper market

    NARCIS (Netherlands)

    Filistrucchi, L.; Klein, T.J.; Michielsen, T.O.

    2012-01-01

    We compare different methods to assess unilateral merger effects in a two-sided market by applying them to a hypothetical merger in the Dutch newspaper industry. We first specify and estimate a structural model of demand for differentiated products in both the readership and the advertising sides of

  16. Calculation method of water injection forward modeling and inversion process in oilfield water injection network

    Science.gov (United States)

    Liu, Long; Liu, Wei

    2018-04-01

    A forward modeling and inversion algorithm is adopted in order to determine the water injection plan in the oilfield water injection network. The main idea of the algorithm is shown as follows: firstly, the oilfield water injection network is inversely calculated. The pumping station demand flow is calculated. Then, forward modeling calculation is carried out for judging whether all water injection wells meet the requirements of injection allocation or not. If all water injection wells meet the requirements of injection allocation, calculation is stopped, otherwise the demand injection allocation flow rate of certain step size is reduced aiming at water injection wells which do not meet requirements, and next iterative operation is started. It is not necessary to list the algorithm into water injection network system algorithm, which can be realized easily. Iterative method is used, which is suitable for computer programming. Experimental result shows that the algorithm is fast and accurate.

  17. Potential benefits of saturation cycle with two-phase refrigerant injection

    International Nuclear Information System (INIS)

    Lee, Hoseong; Hwang, Yunho; Radermacher, Reinhard; Chun, Ho-Hwan

    2013-01-01

    In this paper, a saturation cycle is proposed to enhance a vapor compression cycle performance by reducing thermodynamic losses associated with single phase gas compression and isenthalpic expansion. In order to approach the saturation cycle, a two-phase refrigerant injection technique is applied to the multi-stage cycle. This multi-stage cycle with different options is modeled, and its performance is evaluated under ASHRAE standard operating conditions for air conditioning systems. Moreover, the two-phase refrigerant injection cycle is compared with the typical vapor injection cycle which is utilizing the internal heat exchanger or the flash tank. Low GWP refrigerants are applied to this two-phase refrigerant injection cycle. In terms of the COP and its improvement, R123 has a higher potential than any other refrigerants in the multi-stage cycle. Lastly, practical ideas realizing the saturation cycle are discussed such as multi-stage phase separator, phase separator with helical structure inside, and injection location of the compressor. -- Highlights: • A saturation cycle is proposed to enhance the vapor compression cycle performance. • Two-phase refrigerant injection technique is applied to the multi-stage cycle. • Modeling results of the proposed cycle show the significant performance improvement. • Low GWP refrigerants are applied and R123 shows the highest performance. • New parameters, α and ε, are used to show the potential of the saturation cycle

  18. Upward pricing pressure in two-sided markets

    NARCIS (Netherlands)

    Affeldt, P.; Filistrucchi, L.; Klein, T.J.

    2013-01-01

    Measuring upward pricing pressure (UPP) has recently been proposed by Farrell and Shapiro (2010) as an alternative screening device for horizontal mergers. We extend the concept of UPP to two-sided markets. Examples of such markets are the newspaper market, where the demand for advertising is

  19. Two Azimuthally Separated Regions of Cusp Ion Injection Observed via Energetic Neutral Atoms

    Science.gov (United States)

    Abe, M.; Taguchi, S.; Collier, M. R.; Moore, T. E.

    2011-01-01

    The low-energy neutral atom (LENA) imager on the IMAGE spacecraft can detect energetic neutral atoms produced by ion injection into the cusp through a charge exchange with the Earth's hydrogen exosphere. We examined the occurrence of the LENA cusp signal during positive IMF B(sub z) in terms of the arrival direction and the IMF clock angle theta(sub CA). Results of statistical analyses show that the occurrence frequency is high on the postnoon side when theta(sub CA) is between approximately 20 degrees and approximately 50 degrees. This is ascribed to ion injection caused by cusp reconnection typical of positive IMF B(sub z). Our results also show that there is another situation of high occurrence frequency, which can be identified with theta(sub CA) of approximately 30 degrees to approximately 80 degrees. When theta(sub CA) is relatively large (60 degrees - 80 degrees), occurrence frequencies are high at relatively low latitudes over a wide extent spanning both prenoon and postnoon sectors. This feature suggests that the ion injection is caused by reconnection at the dayside magnetopause. Its postnoon side boundary shifts toward the prenoon as theta(sub CA) decreases. When theta(sub CA) is less than approximately 50 degrees, the high occurrence frequency exists well inside the prenoon sector, which is azimuthally separated from the postnoon region ascribed to cusp reconnection. The prenoon region, which is thought due to ion injection caused by dayside reconnection, may explain the recent report that proton aurora brightening occurs in the unanticipated prenoon sector of the northern high-latitude ionosphere for IMF B(sub y) greater than 0 and B(sub z) greater than 0.

  20. A New High Frequency Injection Method Based on Duty Cycle Shifting without Maximum Voltage Magnitude Loss

    DEFF Research Database (Denmark)

    Wang, Dong; Lu, Kaiyuan; Rasmussen, Peter Omand

    2015-01-01

    The conventional high frequency signal injection method is to superimpose a high frequency voltage signal to the commanded stator voltage before space vector modulation. Therefore, the magnitude of the voltage used for machine torque production is limited. In this paper, a new high frequency...... amplitude. This may be utilized to develop new position estimation algorithm without involving the inductance in the medium to high speed range. As an application example, a developed inductance independent position estimation algorithm using the proposed high frequency injection method is applied to drive...... injection method, in which high frequency signal is generated by shifting the duty cycle between two neighboring switching periods, is proposed. This method allows injecting a high frequency signal at half of the switching frequency without the necessity to sacrifice the machine fundamental voltage...

  1. Ultrasound-guided botulinum toxin injections

    Directory of Open Access Journals (Sweden)

    S. E. Khatkova

    2016-01-01

    Full Text Available One of the key conditions for achieving the desirable result during botulinum toxin therapy for muscular dystonia, spasticity, and other diseases accompanied by spasm, pain, and autonomic dysfunction (dystonias, spasticity, etc. is the proper administration of the agent into the muscles directly involved in the pathological process. The exact entry of botulinum toxin into the target muscles is essential for successful and safe treatment because its injection into a normal muscle may cause side effects. The most common errors are the incorrect depth and incorrect direction of a needle on insertion. Therefore, the exact injection of the agent particularly into the shallow and deep muscles is a difficult task even for an experienced specialist and requires the use of controlling methods.The European Consensus on Botulinum Toxin Therapy points out that various injection techniques are needed for the better identification of necessary muscles. However, there are currently no reports on the clear advantage of any technique. In our country, injections using palpation and anatomical landmarks have been widely used in routine practice so far; electromyographic monitoring and electrostimulation have been less frequently applied. In recent years, the new method ultrasound-guided injection has continued to grow more popular. This effective, accessible, and easy-to-use method makes it possible to manage a real-time injection process and to ensure the exact entry of the agent into the muscle. This paper is dedicated to a comparative analysis of different injection methods and to a description of the ultrasound-guided technique and its advantages over others. 

  2. Spin injection into a two-dimensional electron gas using inter-digital-ferromagnetic contacts

    DEFF Research Database (Denmark)

    Hu, C.M.; Nitta, J.; Jensen, Ane

    2002-01-01

    We present a model that describes the spin injection across a single interface with two electrodes. The spin-injection rate across a typical hybrid junction made of ferromagnet (FM) and a two-dimensional electron gas (2DEG) is found at the percentage level. We perforin spin-injection-detection ex......-injection-detection experiment on devices with two ferromagnetic contacts on a 2DEG confined in an InAs quantum well. A spin-injection rate of 4.5% is estimated from the measured magnetoresistance....

  3. The advertising-financed business model in two-sided media markets

    OpenAIRE

    Anderson, Simon P.; Jullien, Bruno

    2016-01-01

    This chapter focuses on the economic mechanisms at work in recent models of advertising finance in media markets developed around the concept of two-sided markets. The objective is to highlight new and original insights from this approach, and to clarify the conceptual aspects. The chapter first develops a canonical model of two-sided markets for advertising, where platforms deliver content to consumers and resell their "attention" to advertisers. A key distinction is drawn between free media...

  4. Monitoring of density in tokamaks: pumping and gas injection; Controle de la densite dans les tokamaks: pompage et injection de matiere

    Energy Technology Data Exchange (ETDEWEB)

    Dejarnac, R

    2002-11-01

    In thermonuclear fusion devices, controlling the Deuterium-Tritium fuel density and exhausting the Helium ashes is a crucial point. This is achieved by fuelling the discharges by different methods (gas puffing and pellet injection are the most commonly used) and by implementing pumping devices at the plasma periphery. These two issues are treated in this work, both from an experimental and a modelling point of view, using the neutral transport code EIRENE as main tool for our studies. As far as pumping is concerned, we have modelled the outboard pump limiter of the Tore Supra tokamak with the EIRENE code to which we coupled a plasma module specially developed to simulate the neutrals and the plasma in a coherent way. This allowed to validate the code against experimental data. As far as plasma fuelling is concerned, we present here an original method: the supersonic pulsed gas injection (SPGI). This intermediate method between conventional gas puff (GP) and pellet injection was designed and tested at Tore Supra. It consists of injecting very dense and short gas puffs at high speed into the plasma. Experimentally, SPGI was found to have a better fuelling efficiency than GP and to lead to a strong plasma cooling. The mechanisms responsible for this improved efficiency are analysed by modelling, using the EIRENE code to determine the ionisation source and a 1 D transport model to reproduce the plasma density response. At last, an extrapolation of the present injector is presented, discussing the possibility to obtain a radial drift of the injected matter as observed in the case of high field side pellet injection. (author)

  5. Free convection performance of circular cavities having two active curved vertical sides and two inactive curved horizontal sides

    International Nuclear Information System (INIS)

    Ridouane, El Hassan; Campo, Antonio

    2006-01-01

    A detailed review of the archival reveals that the heat transfer and fluid flow characteristics of circular cavities have not been investigated so far and of course their physical features are not understood. A prominent application of these cavities arises in the miniaturized packaging of electronic components that are subject to strict constraints. This paper addresses primarily steady-state laminar natural convection of air in a circular cavity of diameter H inscribed in a square cavity of side H where the corresponding sides are in contact at four points. A third cavity, an arc-square cavity whose shape lies between the square and circular cavity shapes is included in the analysis. The finite volume method is used to perform the numerical simulations. The methodology takes into account the second-order-accurate QUICK scheme for the discretization of the convective term, whereas the pressure-velocity coupling is handled with the SIMPLE scheme. Since the air is not assumed a Boussinesq gas, it was decided to take all thermophysical properties as temperature-dependent. In the end, it has been demonstrated that the circular cavity possesses a superior balance between heat transfer enhancement and size in cross-section area in comparison with the standard square cavity. The side of the square cavity is similar to the diameter of the circular cavity

  6. Grammars with two-sided contexts

    Directory of Open Access Journals (Sweden)

    Mikhail Barash

    2014-05-01

    Full Text Available In a recent paper (M. Barash, A. Okhotin, "Defining contexts in context-free grammars", LATA 2012, the authors introduced an extension of the context-free grammars equipped with an operator for referring to the left context of the substring being defined. This paper proposes a more general model, in which context specifications may be two-sided, that is, both the left and the right contexts can be specified by the corresponding operators. The paper gives the definitions and establishes the basic theory of such grammars, leading to a normal form and a parsing algorithm working in time O(n^4, where n is the length of the input string.

  7. Two consecutive levels of unilateral cervical spondylolysis on opposite sides

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Kyeong Hwa; Kim, Seon Jeong; KIm Ok Hwa; Kim, Seung Ho; Lee, Kwang Hwi; Beak, Hye Jin; Lee, Ye Daun [Dept. of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Busan (Korea, Republic of); Cha, Yoon Ki [Dept. of Radiology, Dongguk University College of Medicine, Ilsan Hospital, Goyang (Korea, Republic of)

    2015-09-15

    Cervical spondylolysis, with or without spondylolisthesis, is a rare condition defined as a corticated cleft between the superior and inferior articular facets of the articular pillar. The defect occurs predominantly at C6, and is usually bilateral in up to two-thirds of cases. Multilevel involvement is uncommon, however, to date, no case of two consecutive levels of unilateral cervical spondylolysis on opposite sides has been reported. Here, we report a rare case of a patient affected by two consecutive levels of unilateral cervical spondylolysis at C5 and C6 on opposite sides in a 19-year-old male complaining of neck pain.

  8. Two consecutive levels of unilateral cervical spondylolysis on opposite sides

    International Nuclear Information System (INIS)

    Ryu, Kyeong Hwa; Kim, Seon Jeong; KIm Ok Hwa; Kim, Seung Ho; Lee, Kwang Hwi; Beak, Hye Jin; Lee, Ye Daun; Cha, Yoon Ki

    2015-01-01

    Cervical spondylolysis, with or without spondylolisthesis, is a rare condition defined as a corticated cleft between the superior and inferior articular facets of the articular pillar. The defect occurs predominantly at C6, and is usually bilateral in up to two-thirds of cases. Multilevel involvement is uncommon, however, to date, no case of two consecutive levels of unilateral cervical spondylolysis on opposite sides has been reported. Here, we report a rare case of a patient affected by two consecutive levels of unilateral cervical spondylolysis at C5 and C6 on opposite sides in a 19-year-old male complaining of neck pain

  9. Application of response surface methodology (RSM) and genetic algorithm in minimizing warpage on side arm

    Science.gov (United States)

    Raimee, N. A.; Fathullah, M.; Shayfull, Z.; Nasir, S. M.; Hazwan, M. H. M.

    2017-09-01

    The plastic injection moulding process produces large numbers of parts of high quality with great accuracy and quickly. It has widely used for production of plastic part with various shapes and geometries. Side arm is one of the product using injection moulding to manufacture it. However, there are some difficulties in adjusting the parameter variables which are mould temperature, melt temperature, packing pressure, packing time and cooling time as there are warpage happen at the tip part of side arm. Therefore, the work reported herein is about minimizing warpage on side arm product by optimizing the process parameter using Response Surface Methodology (RSM) and with additional artificial intelligence (AI) method which is Genetic Algorithm (GA).

  10. Plastic Injection Quality Controlling Using the Lean Six Sigma and FMEA Method

    Science.gov (United States)

    Mansur, A.; Mu'alim; Sunaryo

    2016-01-01

    PT. Yogya Presisi Teknikatama Industri (PT. YPTI) is a mold, precision part, and plastic injection maker company. One of the obstacles faced by the company is the high level of nonconformity on its production results. The waste on production process can be identified and classified into four types, i.e.: a). during the process of injection molding machines, b). finishing and cutting processes, c). quality control process and d). the packaging process. The objectives of this research are minimizing the defective goods and reducing the waste using Lean Six Sigma and FMEA approaches, especially for Bush product. From the analysis result, defective types on Bush product can be classified into bubble, speckle, short shoot, sunken, sink mark, over-cut, flashing, and discolor. Based on the attributes data on Bush product, the DPMO score is 988.42 or the sigma level is 4.6, While the DPMO score on the variable data on each dimension i.e.: a). Slit width on the bottom side has DPMO score of 30119 (sigma level 3.37), b). Diameter of the circle on the top side has DPMO score of 392294 (sigma level 1.77), c). Product thickness on the top side has DPMO score of 70474 (sigma level 2.97), d). Product height has DPMO score of 82107 (sigma level 2.89), product thickness on the bottom side has DPMO score of 24448 (sigma level 3.47), and f). Diameter of the circle on the bottom side has DPMO score of 24448 (sigma level 3.47). The highest RPN score on the dominant types of product defects which needs improvement are the defective goods of bubble type has RPN score of 729, flashing and the molten material out on the heating channel has RPN score of 384, over cutting has RPN score of 324 and sink mark has RPN score of 270. The recommendations for improvement that can be given from this research are making checklist for maintenance and production monitoring, enhancing work supervision and inspection, as well as improving the environment and work stations.

  11. Developing of two-dimensional model of the corium cooling and behavior with non-condensible gas injection

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chang Hyun; Cho, Jae Seon; Kim, Ju Youl; Kim, Do Hyoung [Seoul National University, Seoul (Korea, Republic of)

    1997-07-01

    The purpose of this study is to understand the effect of the non-condensible gas injection into the molten corium on the heat transfer and dynamic behavior within the melt when molten core-concrete interaction occurs during the hypothetical severe accident. Corium behavior with gas injection effect is two phase fluid pattern in which droplet has dispersed gas phase in continuous liquid phase of corium. To analyze this behavior, two dimensional governing equation using the governing equation, the computer program is accomplished using the finite difference method and SIMPLER algorithm. And benchmarking calculation is performed for the KfK experiment, which consider the gas injection effect. After this pre-calculation, an analyses is performed with typical corium under severe accidents. It is concluded that the heat transfer within corium increases as the metal components of the corium and gas injection velocity increase. 88 refs., 23 tabs., 35 figs. (author)

  12. Embolic stroke associated with injection of buprenorphine tablets.

    Science.gov (United States)

    Lim, C C Tchoyoson; Lee, Sze Haur; Wong, Yee-Choon; Hui, Francis

    2009-09-15

    Drug users who crush, dissolve, and inject buprenorphine tablets parenterally may be at risk of severe thromboembolic complications or death. We describe patients with neurologic complications after injecting buprenorphine tablets. Brain MRI including diffusion-weighted imaging (DWI) in patients admitted to the neurologic department after injecting buprenorphine tablets were reviewed. Seven men had neurologic complications after buprenorphine tablet injection. In 5 patients, multiple small scattered hyperintense lesions were detected on DWI in the cortex, white matter, and basal ganglia of the cerebral hemisphere; one patient had a single small lesion. The side of MRI abnormality corresponded to the side of needle marks on the neck except in one patient who had bilateral injections. One patient, who denied injecting into the neck, had DWI abnormalities in the middle cerebral artery territory on one side and occlusion of the ipsilateral internal carotid artery. Buprenorphine tablets can be intentionally or inadvertently injected into the carotid artery, causing a characteristic appearance on diffusion-weighted imaging, consistent with embolic cerebral infarction.

  13. Method and apparatus for injecting fluid

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, W E

    1966-07-05

    A method and apparatus are described for injecting grouting material into porous, fractured, unconsolidated, or other formations, whose cohesion is to be increased and/or whose permeability is to be decreased. A tool for injecting the fluid consists of a packer and valves through which the pressurized fluid may pass from the interior of the tool to the packer to expand it. Another valve allows pressure fluid to be vented so as to allow contraction of the packer. A third valve allows a flow of pressurized flow out of the tool and into the material when a predetermined pressure within the tool has been attained. (9 claims)

  14. Two component injection moulding: an interface quality and bond strength dilemma

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2008-01-01

    on quality parameters of the two component parts. Most engineering applications of two component injection moulding calls for high bond strength between the two polymers, on the other hand a sharp and well-defined interface between the two polymers are required for applications like selective metallization...... of polymers, parts for micro applications and also for the aesthetic purpose of the final product. The investigation presented in this paper indicates a dilemma between obtaining reasonably good bond strength and at the same time keeping the interface quality suitable for applications. The required process...... conditions for a sharp and well-defined interface are exactly the opposite of what is congenial for higher bond strength. So in the production of two component injection moulded parts, there is a compromise to make between the interface quality and the bond strength of the two polymers. Also the injection...

  15. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Science.gov (United States)

    Lee, Petry Y. R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung

    2012-10-01

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter ( D/ d = 2), spaced by a gap ratio 0.75 ( G/ D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 ≤ f e / f os ≤ 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f e / f os = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f e /3 (or f os ), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 ≤ f e / f os ≤ 3.22 is also not locked-on because the phase difference in the narrow wake excited at f e / f os = 2.93 and 3.07 changes significantly. Note f e and f os denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively.

  16. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Petry Y.R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung [National Chung Hsing University, Department of Mechanical Engineering, Taichung (China)

    2012-10-15

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter (D/d = 2), spaced by a gap ratio 0.75 (G/D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 {<=} f{sub e} /f{sub os} {<=} 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f{sub e} /f{sub os} = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f{sub e} /3 (or f{sub os}), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 {<=} f{sub e} /f{sub os} {<=} 3.22 is also not locked-on because the phase difference in the narrow wake excited at f{sub e} /f{sub os} = 2.93 and 3.07 changes significantly. Note f{sub e} and f{sub os} denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively. (orig.)

  17. Two component micro injection molding for MID fabrication

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2009-01-01

    Molded Interconnect Devices (MIDs) are plastic substrates with electrical infrastructure. The fabrication of MIDs is usually based on injection molding and different process chains may be identified from this starting point. The use of MIDs has been driven primarily by the automotive sector......, but recently the medical sector seems more and more interested. In particular the possibility of miniaturization of 3D components with electrical infrastructure is attractive. The paper describes possible manufacturing routes and challenges of miniaturized MIDs based on two component micro injection molding...

  18. Optimising the Design Process of the Injection Camshaft by Critical Path Method (CPM

    Directory of Open Access Journals (Sweden)

    Olga-Ioana Amariei

    2016-10-01

    Full Text Available In the present paper a series of advantages of the CPM method are presented, focusing on the optimization of design duration of an injection camshaft, by cost criteria. The minimum duration of finalizing the design of the injection camshaft will be determined, as well as the total cost associated to this project, normally, and then under crash regime. At the end, two types of sensitivity analysis will be performed: Meeting the desire completation time and Meeting the desired budget cost

  19. High Bandwidth Zero Voltage Injection Method for Sensorless Control of PMSM

    DEFF Research Database (Denmark)

    Ge, Xie; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2014-01-01

    High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses to be inj......High frequency signal injection is widely used in PMSM sensorless control system for low speed operations. The conventional voltage injection method often needs filters to obtain particular harmonic component in order to estimate the rotor position; or it requires several voltage pulses...... in a fast current regulation performance. Injection of zero voltage also minimizes the inverter voltage error effects caused by the dead-time....

  20. [Management of complications after aesthetic hyaluronic acid injections].

    Science.gov (United States)

    Jahn, K; Homey, B; Gerber, P A

    2014-10-01

    The use of hyaluronic acid fillers for treatment of rhytides (wrinkles) is widespread in aesthetic dermatology and is considered a safe procedure; however, complications can occur especially if the injections are carried out by an inexperienced person and/or with a lack of anatomical knowledge. The two cases presented here exemplify this problem. In conclusion, both cases demonstrate complications after uncritical injection of hyaluronic acid fillers into "risk" or "expert" regions. While the patients in these two cases recovered completely, the injection of filler substances can also lead to the risk of potentially permanent side effects, such as granuloma, necrosis with scar tissue formation and even blindness. The frequency and severity of complications often show a direct correlation with the qualification or expertise of the person treating and hence injection treatments should be performed solely by physicians.

  1. Monitoring of density in tokamaks: pumping and gas injection

    International Nuclear Information System (INIS)

    Dejarnac, R.

    2002-11-01

    In thermonuclear fusion devices, controlling the Deuterium-Tritium fuel density and exhausting the Helium ashes is a crucial point. This is achieved by fuelling the discharges by different methods (gas puffing and pellet injection are the most commonly used) and by implementing pumping devices at the plasma periphery. These two issues are treated in this work, both from an experimental and a modelling point of view, using the neutral transport code EIRENE as main tool for our studies. As far as pumping is concerned, we have modelled the outboard pump limiter of the Tore Supra tokamak with the EIRENE code to which we coupled a plasma module specially developed to simulate the neutrals and the plasma in a coherent way. This allowed to validate the code against experimental data. As far as plasma fuelling is concerned, we present here an original method: the supersonic pulsed gas injection (SPGI). This intermediate method between conventional gas puff (GP) and pellet injection was designed and tested at Tore Supra. It consists of injecting very dense and short gas puffs at high speed into the plasma. Experimentally, SPGI was found to have a better fuelling efficiency than GP and to lead to a strong plasma cooling. The mechanisms responsible for this improved efficiency are analysed by modelling, using the EIRENE code to determine the ionisation source and a 1 D transport model to reproduce the plasma density response. At last, an extrapolation of the present injector is presented, discussing the possibility to obtain a radial drift of the injected matter as observed in the case of high field side pellet injection. (author)

  2. Botulinum toxin injection in laryngeal dyspnea.

    Science.gov (United States)

    Woisard, Virginie; Liu, Xuelai; Bes, Marie Christine Arné; Simonetta-Moreau, Marion

    2017-02-01

    Data, regarding the use of botulinum toxin (BT-A) in laryngeal dyspnea, are scarce, coming from some cases reports in the literature, including Vocal fold paralysis, laryngeal dystonia, vocal cord dysfunction also called paradoxical motion of the vocal fold (PMVF), and post-neuroleptic laryngeal dyskinesia. There is no consensus regarding the muscles and the doses to inject. The aim of this study is to present a retrospective review of patients treated in our ENT Department by BT-A injection in this indication. This study is a retrospective study describing patients who underwent an injection of botulinum toxin for laryngeal dyspnea in the ENT Department from 2005 to 2015 years. The inclusion criteria were a dyspnea associated with a laryngeal dysfunction, confirmed by flexible fiberoptic nasopharyngolaryngoscopy. Information concerning the causes of the dyspnea, the botulinum toxin BT-A injections procedure, post-injection follow-up, and respiratory outcome were collected for all patients included. In the group of 13 patients included, the main cause identified as principal factor linked with the short breath was: a bilateral VF paralysis (Patel et al., Otolaryngol Head Neck Surg 130:686-689, 7), laryngeal dystonia (Balkissoon and Kenn, Semin Respir Crit Care Med 33:595-605, 2), Anxiety syndrome associated with unilateral vocal fold paralysis or asthma (Marcinow et al., Laryngoscope 124:1425-1430, 3), and an isolated asthma (Zwirner et al., Eur Arch Otorhinolaryngol 254:242-245, 1). Nine out of the thirteen patients were improved by the injections. A BT-A-induced stable benefit for four patients led them to stop the injections in the follow-up. Good outcome was observed in five other patients (main cause: bilateral VP paralysis), allowing a progressive lengthening of the delay between BT-A injections. Four patients did not report a positive risk/benefit ratio after BT-A injections; two of them (with bilateral VF paralysis), because of respiratory side effects and

  3. Comparison of two chair-side tests for enumeration of Mutans Streptococci in saliva

    DEFF Research Database (Denmark)

    Twetman, Lisa; Twetman, Svante

    2014-01-01

    AIM: To compare the prevalence and levels of salivary Mutans Streptococci (MS) assessed with two commercial chair-side methods based on culture growth or monoclonal antibodies, respectively. MATERIAL AND METHODS: The study group consisted of a convenience sample of 89 adults, 23-72 years of age......, referred to a maxillofacial hospital clinic with a caries history. Stimulated whole saliva samples were collected and the number of MS was assessed with the Dentocult-SM Strip Mutans (DSM) and the Saliva-Check Mutans (SCM). The outcome was compared with conventional anaerobic laboratory cultivation...

  4. An investigation of methods for injecting emissions from boreal wildfires using WRF-Chem during ARCTAS

    Science.gov (United States)

    Sessions, W. R.; Fuelberg, H. E.; Kahn, R. A.; Winker, D. M.

    2011-06-01

    The Weather Research and Forecasting Model (WRF) is considered a "next generation" mesoscale meteorology model. The inclusion of a chemistry module (WRF-Chem) allows transport simulations of chemical and aerosol species such as those observed during NASA's Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) in 2008. The ARCTAS summer deployment phase during June and July coincided with large boreal wildfires in Saskatchewan and Eastern Russia. One of the most important aspects of simulating wildfire plume transport is the height at which emissions are injected. WRF-Chem contains an integrated one-dimensional plume rise model to determine the appropriate injection layer. The plume rise model accounts for thermal buoyancy associated with fires and local atmospheric stability. This paper describes a case study of a 10 day period during the Spring phase of ARCTAS. It compares results from the plume model against those of two more traditional injection methods: Injecting within the planetary boundary layer, and in a layer 3-5 km above ground level. Fire locations are satellite derived from the GOES Wildfire Automated Biomass Burning Algorithm (WF_ABBA) and the MODIS thermal hotspot detection. Two methods for preprocessing these fire data are compared: The prep_chem_sources method included with WRF-Chem, and the Naval Research Laboratory's Fire Locating and Monitoring of Burning Emissions (FLAMBE). Results from the simulations are compared with satellite-derived products from the AIRS, MISR and CALIOP sensors. When FLAMBE provides input to the 1-D plume rise model, the resulting injection heights exhibit the best agreement with satellite-observed injection heights. The FLAMBE-derived heights are more realistic than those utilizing prep_chem_sources. Conversely, when the planetary boundary layer or the 3-5 km a.g.l. layer were filled with emissions, the resulting injection heights exhibit less agreement with observed plume heights

  5. Progestogen-only injectable contraceptive: Experience of women in ...

    African Journals Online (AJOL)

    Background: Progestogen-only injectable contraceptive is a long-acting contraceptive given intramuscularly to give protection against unwanted pregnancy for a period of 2 or 3 months, depending on the type. Alterations in menstrual pattern are a well known side effect of this effective contraceptive method. Objectives: To ...

  6. Two component micro injection moulding for moulded interconnect devices

    DEFF Research Database (Denmark)

    Islam, Aminul

    2008-01-01

    Moulded interconnect devices (MIDs) contain huge possibilities for many applications in micro electro-mechanical-systems because of their capability of reducing the number of components, process steps and finally in miniaturization of the product. Among the available MID process chains, two...... component injection moulding is one of the most industrially adaptive processes. However, the use of two component injection moulding for MID fabrication, with circuit patterns in the sub-millimeter range, is still a big challenge at the present state of technology. The scope of the current Ph.D. project...... and a reasonable adhesion between them. • Selective metallization of the two component plastic part (coating one polymer with metal and leaving the other one uncoated) To overcome these two main issues in MID fabrication for micro applications, the current Ph.D. project explores the technical difficulties...

  7. Comparison of side effects in myelography with iopamidol and metrizamide

    International Nuclear Information System (INIS)

    Lee, Yong; Kang, Heung Sik; Chang, Kee Hyun; Han, Seoul Heui; Kwon, Oh Sung; Myung, Ho Gin

    1986-01-01

    The study was conducted to compare the side effects in myelography of the two non-ionic water-soluble contrast medias, lopamidol (Niopam) and Metrizamide (Amipaque). A total of 111 patients were examined, 64 with lopamidol and 47 with Metrizamide. Side effects consisted of headache, nausea, vomiting, dizziness, urinary difficulty, muscular pain, seizure, neurobehavioral disturbance, neurological sign change, vital sign change and etc. The common side effects were headache, nausea, vomiting and dizziness in order of frequency. Most of the side effects were subsided within 24 hours following myelography. lopamidol myelography caused fewer and milder side effects than Metrizamide study. The side effects were more commonly observed in cervical, thoracic or total myelography than in lumbar myelography with either lopamidol or Metrizamide. There was no significant correlation between incidence of the side effects and premedication with phenobarbital or valium injection before myelography and CSF sampling during the procedure.

  8. Comparison of side effects in myelography with iopamidol and metrizamide

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong; Kang, Heung Sik; Chang, Kee Hyun; Han, Seoul Heui; Kwon, Oh Sung; Myung, Ho Gin [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-12-15

    The study was conducted to compare the side effects in myelography of the two non-ionic water-soluble contrast medias, lopamidol (Niopam) and Metrizamide (Amipaque). A total of 111 patients were examined, 64 with lopamidol and 47 with Metrizamide. Side effects consisted of headache, nausea, vomiting, dizziness, urinary difficulty, muscular pain, seizure, neurobehavioral disturbance, neurological sign change, vital sign change and etc. The common side effects were headache, nausea, vomiting and dizziness in order of frequency. Most of the side effects were subsided within 24 hours following myelography. lopamidol myelography caused fewer and milder side effects than Metrizamide study. The side effects were more commonly observed in cervical, thoracic or total myelography than in lumbar myelography with either lopamidol or Metrizamide. There was no significant correlation between incidence of the side effects and premedication with phenobarbital or valium injection before myelography and CSF sampling during the procedure.

  9. [Results of treatment for high-pressure injection hand injuries].

    Science.gov (United States)

    Zyluk, A; Walaszek, I

    2000-01-01

    High-pressure injection injuries of the hand have a reputation for being dangerous for individual fingers and even for whole hand. Usually appearing innocuous at presentation because of small puncture entry wound, these injuries result in severe damage of most internal structures in finger and hand due to extensive penetration of injected substance. This paper reviews the outcome of the treatment of such injuries in 10 patients: 9 sustained injection of toxic paint, and one lead shot. All the patients were operated on: eight a few hours after injury and two with 3 days delay. The surgical technique included wide exposure from site of injection up to the farthest place in which foreign substance was seen. Thorough debridment of injected material and contaminated tissue was performed with careful preservation of neurovascular structures and tendons. Wounds were not closed, but managed by open technique. In all patients wounds healed well: in 3 by secondary intention, in 6 by delayed closure and 2 were covered by skin grafts. No amputation was performed. Final results were assessed form 1.5 to 3.5 years after initial injury (mean at 2.5 years). Two patients complained of moderate pain related to the weather, five of cold intolerance and two of impaired sensation on fingertips. Active range of motion of affected fingers was in whole group from 90% to 104% (mean 97%) of the range of motion of unaffected fingers from the other side. Range of motion of the wrist (2 patients) was 76% and 117% of range of motion of the other side. Pinch grip strength was from 81% to 116% (mean 99%), and global grip strength from 77% to 119% (mean 97%) of the other side. All patients went back to their previous jobs and periods of sick leave were from 2 weeks to 6 months (mean 3 mo). Excellent results achieved in this study--full functional recovery in 9 of 10 patients confirm the effectiveness of aggressive treatment by open wound technique of such injuries.

  10. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  11. The Position of Lingula as an Index for Inferior Alveolar Nerve Block Injection in 7-11-Year-Old Children

    Directory of Open Access Journals (Sweden)

    Fatemeh Ezoddini Ardakani

    2010-06-01

    Full Text Available Background and aims. Inferior alveolar nerve block injection is one of the common intra oral anesthetic techniques, with a failure rate of 15-20%. The aim of this study was to evaluate the position of the lingula as an index for this injection. Materials and methods. Thirty eight panoramic radiographs of 7–11 year old patients were analyzed and the distance between the lingula index and occlusal plane was measured. Then, lower alveolar nerve block injection was performed on 88 children. Finally, a visual analogue scale was used to measure the rate of pain in the patients. Results. This distance increased with age and in children younger than nine years is −0.45 mm on the right side and −0.95 mm on the left side. This distance in children older than 9 years is −0.23 mm on the right side and 0.47 mm on the left side. The success rates of inferior alveolar nerve block injection based on lingual index were 49% on the right side and 53.8% on the left side. Conclusion. As the lingual index has various positions and its distance from the occlusal plane increases with age, it is not an appropriate landmark for inferior alveolar nerve block injection.

  12. Cold water injection into two-phase mixtures

    International Nuclear Information System (INIS)

    1989-07-01

    This report presents the results of a review of the international literature regarding the dynamic loadings associated with the injection of cold water into two-phase mixtures. The review placed emphasis on waterhammer in nuclear power plants. Waterhammmer incidence data were reviewed for information related to thermalhydraulic conditions, underlying causes and consequential damage. Condensation induced waterhammer was found to be the most significant consequence of injecting cold water into a two-phase system. Several severe waterhammer incidents have been attributed to slug formation and steam bubble collapse under conditions of stratified steam and cold water flows. These phenomena are complex and not well understood. The current body of experimental and analytical knowledge is not large enough to establish maps of expected regimes of condensation induced waterhammer. The Electric Power Research Institute, in the United States, has undertaken a major research and development programme to develop the knowledge base for this area. The limited models and data currently available show that mechanical parameters are as important as thermodynamic conditions for the initiation of condensation induced waterhammer. Examples of bounds for avoiding two-phase waterhammer are given. These bounds are system specific and depend upon parameters such as pump capacity, pipe length and pipe orientation

  13. Comparison of two setups for induction heating in injection molding

    DEFF Research Database (Denmark)

    Menotti, Stefano; Hansen, Hans Nørgaard; Bissacco, Giuliano

    2015-01-01

    To eliminate defects and improve the quality of molded parts, increasing the mold temperature is one of the applicable solutions. A high mold temperature can increase the path flow of the polymer inside the cavity allowing reduction of the number of injection points, reduction of part thickness......, and moulding of smaller and more complex geometries. The last two aspects are very important in micro injection molding. In this paper, a new embedded induction heating system is proposed and validated and two different coil setups were tested and compared. An experimental investigation was performed based...

  14. Objective and subjective methods for quantifying training load in wheelchair basketball small-sided games.

    Science.gov (United States)

    Iturricastillo, Aitor; Granados, Cristina; Los Arcos, Asier; Yanci, Javier

    2017-04-01

    The aim of the present study was to analyse the training load in wheelchair basketball small-sided games and determine the relationship between heart rate (HR)-based training load and perceived exertion (RPE)-based training load methods among small-sided games bouts. HR-based measurements of training load included Edwards' training load and Stagno's training impulses (TRIMP MOD ) while RPE-based training load measurements included cardiopulmonary (session RPEres) and muscular (session RPEmus) values. Data were collected from 12 wheelchair basketball players during five consecutive weeks. The total load for the small-sided games sessions was 67.5 ± 6.7 and 55.3 ± 12.5 AU in HR-based training load (Edwards' training load and TRIMP MOD ), while the RPE-based training loads were 99.3 ± 26.9 (session RPEres) and 100.8 ± 31.2 AU (session RPEmus). Bout-to-bout analysis identified greater session RPEmus in the third [P training loads. It is suggested that HR-based and RPE-based training loads provide different information, but these two methods could be complementary because one method could help us to understand the limitations of the other.

  15. Large scale gas injection test (Lasgit): Results from two gas injection tests

    International Nuclear Information System (INIS)

    Cuss, R. J.; Harrington, J. F.; Noy, D. J.; Wikman, A.; Sellin, P.

    2011-01-01

    This paper describes the initial results from a large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory (Sweden)). Lasgit is a full-scale field-scale experiment based on the Swedish KBS-3V repository concept, examining the processes controlling gas and water flow in compact buffer bentonite. The first 2 years of the test focused on the artificial hydration of the bentonite buffer. This was followed by a programme of hydraulic and gas injection tests which ran from day 843 to 1110. A further period of artificial hydration occurred from day 1110 to 1385, followed by a more complex programme of gas injection testing which remains on going (day 1385+). After 2 years of hydration, hydraulic conductivity and specific storage values in the lower filter array were found to range from 9 x 10 -14 to 1.6 x 10 -13 m/s and 5.5 x 10 -5 to 4.4 x 10 -4 m -1 respectively, with the injection filter FL903 yielding values of 7.5 x 10 -14 m/s and 2.5 x 10 -5 m -1 . A second set of hydraulic measurements were performed over 1 year and a half later yielding similar values, in the range 7.8 x 10 -14 m/s and 1.3 x 10 -13 m/s. The hydraulic conductivity of FL903 had reduced slightly to 5.3 x 10 -14 m/s while specific storage had increased to 4.0 x 10 -5 m -1 . Both datasets agree with laboratory values performed on small-scale saturated samples. Two sets of gas injection tests were performed over a 3 year period. During the course of testing, gas entry pressure was found to increase from around 650 kPa to approximately 1.3 MPa, indicative of the maturation of the clay. The sequential reduction in volumetric flow rate and lack of correlation between the rate of gas inflow and the gas pressure gradient observed during constant pressure steps prior to major gas entry, is suggestive of a reduction in gas permeability of the buffer and indicates only limited quantities of gas can be injected into the clay without interacting with the continuum stress field. Major gas

  16. High-Pressure Injection Injuries to the Hand

    Directory of Open Access Journals (Sweden)

    Davod Jafari

    2016-07-01

    Full Text Available Background High-pressure injections into the hand, burden devastating and permanent functional impairments. Many materials including paint, paint thinner, gasoline, oil and grease are reported as the causative agents. These injuries need multiple procedures and reconstructions most of the time and 40% of the injuries may end with amputation of the injured part. Objectives The aim of this study was to report the treatment outcomes and methods of treatments of patients with high-pressure injection injuries of the hand. Methods We retrospectively reviewed the medical records, imaging files and demographic data of patients, who were treated at our center due to the high-pressure injuries to their hands. We recorded the kind of the injected materials, time to the first treatment procedure, times of operation, and methods of their treatments. The outcomes of the injuries as well as the deficiency of the digital joints motion were also reported. Results Nine cases with high-pressure injury of the hand were enrolled in this study. All patients were male with mean age of 26.88 ± 7.52. Mean follow-up time was 28.55 ± 12.49 months. The dominant hand was the right side in seven patients and left in two patients. Injury was in the left hand of seven patients and right hand of two patients. Index finger was the most common involved part (five cases followed by the thumb (two cases. Injected material was grease in seven cases, water-base paint and water, each in one case.Mean time delay to the first treatment procedure was 29.16 ± 25.66 hours for seven patients. This was exceptionally long for two patients (seven days and 24 months. Type of treatment was debridement and skin graft for three cases, debridement and cross finger flap for two cases, debridement for two cases and nerve graft for one case. Amputation of the necrotic digit was performed for one case. Mean hospitalization time was 8.33 ± 3.64 days for all patients.Mean total active range of motion

  17. Effect of Rotational Speed on the Stability of Two Rotating Side-by-side Circular Cylinders at Low Reynolds Number

    Science.gov (United States)

    Dou, Huashu; Zhang, Shuo; Yang, Hui; Setoguchi, Toshiaki; Kinoue, Yoichi

    2018-04-01

    Flow around two rotating side-by-side circular cylinders of equal diameter D is numerically studied at the Reynolds number 40≤ Re ≤200 and various rotation rate θ i . The incoming flow is assumed to be two-dimensional laminar flow. The governing equations are the incompressible Navier-Stokes equations and solved by the finite volume method (FVM). The ratio of the center-to-center spacing to the cylinder diameter is T/D=2. The objective of the present work is to investigate the effect of rotational speed and Reynolds number on the stability of the flow. The simulation results are compared with the experimental data and a good agreement is achieved. The stability of the flow is analyzed by using the energy gradient theory, which produces the energy gradient function K to identify the region where the flow is the most prone to be destabilized and the degree of the destabilization. Numerical results reveal that K is the most significant at the separated shear layers of the cylinder pair. With Re increases, the length of the wake is shorter and the vortex shedding generally exhibits a symmetrical distribution for θ i < θ crit . It is also shown that the unsteady vortex shedding can be suppressed by rotating the cylinders in the counter-rotating mode.

  18. An investigation of methods for injecting emissions from boreal wildfires using WRF-Chem during ARCTAS

    Directory of Open Access Journals (Sweden)

    W. R. Sessions

    2011-06-01

    Full Text Available The Weather Research and Forecasting Model (WRF is considered a "next generation" mesoscale meteorology model. The inclusion of a chemistry module (WRF-Chem allows transport simulations of chemical and aerosol species such as those observed during NASA's Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS in 2008. The ARCTAS summer deployment phase during June and July coincided with large boreal wildfires in Saskatchewan and Eastern Russia.

    One of the most important aspects of simulating wildfire plume transport is the height at which emissions are injected. WRF-Chem contains an integrated one-dimensional plume rise model to determine the appropriate injection layer. The plume rise model accounts for thermal buoyancy associated with fires and local atmospheric stability. This paper describes a case study of a 10 day period during the Spring phase of ARCTAS. It compares results from the plume model against those of two more traditional injection methods: Injecting within the planetary boundary layer, and in a layer 3–5 km above ground level. Fire locations are satellite derived from the GOES Wildfire Automated Biomass Burning Algorithm (WF_ABBA and the MODIS thermal hotspot detection. Two methods for preprocessing these fire data are compared: The prep_chem_sources method included with WRF-Chem, and the Naval Research Laboratory's Fire Locating and Monitoring of Burning Emissions (FLAMBE. Results from the simulations are compared with satellite-derived products from the AIRS, MISR and CALIOP sensors.

    When FLAMBE provides input to the 1-D plume rise model, the resulting injection heights exhibit the best agreement with satellite-observed injection heights. The FLAMBE-derived heights are more realistic than those utilizing prep_chem_sources. Conversely, when the planetary boundary layer or the 3–5 km a.g.l. layer were filled with emissions, the resulting injection heights exhibit less

  19. Construction of a Direct Water-Injected Two-Stroke Engine for Phased Direct Fuel Injection-High Pressure Charging Investigations

    Science.gov (United States)

    Somsel, James P.

    1998-01-01

    The development of a water injected Orbital Combustion Process (OCP) engine was conducted to assess the viability of using the powerplant for high altitude NASA aircraft and General Aviation (GA) applications. An OCP direct fuel injected, 1.2 liter, three cylinder, two-stroke engine has been enhanced to independently inject water directly into the combustion chamber. The engine currently demonstrates low brake specific fuel consumption capability and an excellent power to weight ratio. With direct water injection, significant improvements can be made to engine power, to knock limits/ignition advance timing, and to engine NO(x) emissions. The principal aim of the testing was to validate a cyclic model developed by the Systems Analysis Branch at NASA Ames Research Center. The work is a continuation of Ames' investigations into a Phased Direct Fuel Injection Engine with High Pressure Charging (PDFI-ITPC).

  20. Method for double-sided processing of thin film transistors

    Science.gov (United States)

    Yuan, Hao-Chih; Wang, Guogong; Eriksson, Mark A.; Evans, Paul G.; Lagally, Max G.; Ma, Zhenqiang

    2008-04-08

    This invention provides methods for fabricating thin film electronic devices with both front- and backside processing capabilities. Using these methods, high temperature processing steps may be carried out during both frontside and backside processing. The methods are well-suited for fabricating back-gate and double-gate field effect transistors, double-sided bipolar transistors and 3D integrated circuits.

  1. Two-component injection moulding simulation of ABS-POM micro structured surfaces

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Islam, Aminul

    2013-01-01

    Multi-component micro injection moulding (μIM) processes such as two-component (2k) μIM are the key technologies for the mass fabrication of multi-material micro products. 2k-μIM experiments involving a miniaturized test component with micro features in the sub-mm dimensional range and moulding...... a pair of thermoplastic materials (ABS and POM) were conducted. Three dimensional process simulations based on the finite element method have been performed to explore the capability of predicting filling pattern shape at component-level and surface micro feature-level in a polymer/polymer overmoulding...

  2. A Reliable Methodology for Determining Seed Viability by Using Hyperspectral Data from Two Sides of Wheat Seeds.

    Science.gov (United States)

    Zhang, Tingting; Wei, Wensong; Zhao, Bin; Wang, Ranran; Li, Mingliu; Yang, Liming; Wang, Jianhua; Sun, Qun

    2018-03-08

    This study investigated the possibility of using visible and near-infrared (VIS/NIR) hyperspectral imaging techniques to discriminate viable and non-viable wheat seeds. Both sides of individual seeds were subjected to hyperspectral imaging (400-1000 nm) to acquire reflectance spectral data. Four spectral datasets, including the ventral groove side, reverse side, mean (the mean of two sides' spectra of every seed), and mixture datasets (two sides' spectra of every seed), were used to construct the models. Classification models, partial least squares discriminant analysis (PLS-DA), and support vector machines (SVM), coupled with some pre-processing methods and successive projections algorithm (SPA), were built for the identification of viable and non-viable seeds. Our results showed that the standard normal variate (SNV)-SPA-PLS-DA model had high classification accuracy for whole seeds (>85.2%) and for viable seeds (>89.5%), and that the prediction set was based on a mixed spectral dataset by only using 16 wavebands. After screening with this model, the final germination of the seed lot could be higher than 89.5%. Here, we develop a reliable methodology for predicting the viability of wheat seeds, showing that the VIS/NIR hyperspectral imaging is an accurate technique for the classification of viable and non-viable wheat seeds in a non-destructive manner.

  3. CT-guided cervical nerve root injections: comparing the immediate post-injection anesthetic-related effects of the transforaminal injection with a new indirect technique

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K.; Zanetti, Marco; Hodler, Juerg

    2011-01-01

    To describe an ''indirect'' cervical nerve root injection technique with a dorsal approach that should carry less inherent risk than the ''direct'' cervical transforaminal injection approach, and to compare the immediate post-injection results of the two procedures. The indirect and direct cervical nerve root injection procedures are described in detail. Fifty-three consecutive patients receiving the indirect nerve root injections during 2009-2010 were age- and gender-matched to 53 patients who underwent direct transforaminal nerve root injections performed in 2006. Pain level data were collected immediately before and 20-30 min after each procedure. The percentages of pain change in the two groups were compared using the unpaired Student's t test. Fifty-two men (mean age 49) and 54 women (mean age 55) were included. The mean percentage of pain reduction for patients receiving indirect nerve root injections was 38.4% and for those undergoing the direct nerve root injections approach it was 43.2%. This was not significantly different (P = 0.455). No immediate or late adverse effects were reported after either injection procedure. The indirect cervical nerve root injection procedure is a potentially safer alternative to direct cervical transforaminal nerve root injections. The short-term pain reduction is similar using the two injection methods. (orig.)

  4. Population and housing: A two-sided relationship

    Directory of Open Access Journals (Sweden)

    Clara H. Mulder

    2006-11-01

    Full Text Available In this paper I explore the relationship between population and housing. I argue that this relationship is two-sided. On the one hand, the size of a population, and particularly the number of households, determines the demand for housing. On the other hand, the availability of suitable and affordable housing may attract certain categories of migrants. It also influences young people's opportunities to leave the parental home, marry or cohabit, and have children. Furthermore, home-ownership hampers residential mobility and migration by binding people to a place.

  5. Simulation of Jetting in Injection Molding Using a Finite Volume Method

    Directory of Open Access Journals (Sweden)

    Shaozhen Hua

    2016-05-01

    Full Text Available In order to predict the jetting and the subsequent buckling flow more accurately, a three dimensional melt flow model was established on a viscous, incompressible, and non-isothermal fluid, and a control volume-based finite volume method was employed to discretize the governing equations. A two-fold iterative method was proposed to decouple the dependence among pressure, velocity, and temperature so as to reduce the computation and improve the numerical stability. Based on the proposed theoretical model and numerical method, a program code was developed to simulate melt front progress and flow fields. The numerical simulations for different injection speeds, melt temperatures, and gate locations were carried out to explore the jetting mechanism. The results indicate the filling pattern depends on the competition between inertial and viscous forces. When inertial force exceeds the viscous force jetting occurs, then it changes to a buckling flow as the viscous force competes over the inertial force. Once the melt contacts with the mold wall, the melt filling switches to conventional sequential filling mode. Numerical results also indicate jetting length increases with injection speed but changes little with melt temperature. The reasonable agreements between simulated and experimental jetting length and buckling frequency imply the proposed method is valid for jetting simulation.

  6. DMPD: Targeting bacterial endotoxin: two sides of a coin. [Dynamic Macrophage Pathway CSML Database

    Lifescience Database Archive (English)

    Full Text Available n M. Ann N Y Acad Sci. 2007 Jan;1096:1-17. (.png) (.svg) (.html) (.csml) Show Targeting bacterial endotoxin: two sides of a coin. Pub...medID 17405910 Title Targeting bacterial endotoxin: two sides of a coin. Authors Bo

  7. Efficacy of Intra-Articular Injection of Hyaluronic Acid in the Treatment of Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    SS Narayanan

    2009-05-01

    Full Text Available This study was conducted to evaluate the efficacy of intra- articular injection of hyaluronic acid for the treatment of knee osteoarthritis. Patients with knee osteoarthritis were followed for a period of six months to assess the efficacy of intra-articular injection of hyaluronic acid given three times in three consecutive weeks. Fifty patients were reviewed at two, eight and 24 weeks post-injection. The average age was 60.9 years and female to male ratio was 3:1. Patients were assessed using the Lequesne Algofunctional Index for function, and the visual analogue score for pain and side effects. We found that the knee pain reduced and the function improved in most patients and these beneficial effects maintain till the last follow up. The only side effect noted was one case of acute non-septic joint effusion after the 3rd injection. We concluded that intra-articular injection of hyaluronic acid can produce pain relief and functional improvement for up to 6 months.

  8. Treatment of hyperfunctioning thyroid nodules by percutaneous ethanol injection.

    Science.gov (United States)

    Larijani, Bagher; Pajouhi, Mohammad; Ghanaati, Hossein; Bastanhagh, Mohammad-Hassan; Abbasvandi, Fereshteh; Firooznia, Kazem; Shirzad, Mahmood; Amini, Mohammad-Reza; Sarai, Maryam; Abbasvandi, Nasreen; Baradar-Jalili, Reza

    2002-12-06

    BACKGROUND: Autonomous thyroid nodules can be treated by a variety of methods. We assessed the efficacy of percutaneous ethanol injection in treating autonomous thyroid nodules. METHODS: 35 patients diagnosed by technetium-99 scanning with hyperfunctioning nodules and suppressed sensitive TSH (sTSH) were given sterile ethanol injections under ultrasound guidance. 29 patients had clinical and biochemical hyperthyroidism. The other 6 had sub-clinical hyperthyroidism with suppressed sTSH levels (thyroid hormone levels. Ethanol injections were performed once every 1-4 weeks. Ethanol injections were stopped when serum T3, T4 and sTSH levels had returned to normal, or else injections could no longer be performed because significant side effects. Patients were followed up at 3, 6 and, in 15 patients, 24 months after the last injection. RESULTS: Average pre-treatment nodule volume [18.2 PlusMinus; 12.7 ml] decreased to 5.7 PlusMinus; 4.6 ml at 6 months follow-up [P thyroid hormone levels at 3 and 6 months follow-up [P 0.05]. Ethanol injections were well tolerated by the patients, with only 2 cases of transient dysphonia. CONCLUSION: Our findings indicate that ethanol injection is an alternative to surgery or radioactive iodine in the treatment of autonomous thyroid nodules.

  9. MATHEMATICAL SIMULATION OF CONCURRENT TWO-SIDED LENS PROCESSING

    Directory of Open Access Journals (Sweden)

    A. S. Kozeruk

    2015-01-01

    Full Text Available The purpose of the paper is to modernize technology for obtaining high-accuracy lenses with fine centre. Presently their operating surfaces are fixed  to an accessory with the help of adhesive substance that leads to elastic deformation in glass and causes local errors in lens parts.A mathematical model for concurrent two-sided processing of high-accuracy optical parts with spherical surfaces has been developed in the paper. The paper presents analytical expressions that permit to calculate sliding speed at any point on the processed spherical surface depending on type and value of technological equipment settings. Calculation of parameter Q = Pv in a diametric section of the convexo-concave lens has been carried out while using these expressions together with functional dependence of pressure on contact zone еarea of tool and part bedding surfaces.Theoretical and experimental investigations have been carried out with the purpose to study changes in Q parameter according to the processed lens surface for various setting parameters of the technological equipment and their optimum values ensuring preferential stock removal in the central or boundary part zone or uniform distribution of the removal along the whole processed surface have been determined in the paper.The paper proposes a machine tool scheme for concurrent two-sided grinding and polishing of lenses while fixing their side (cylindrical surface. Machine tool kinematics makes it possible flexibly and within wide limits to change its setting parameters  that significantly facilitates the control of form-building process of parts with highly-precise spherical surfaces.Methodology for investigations presupposes the following: mathematical simulation of highly-precise spherical surface form-building process under conditions of forced closing, execution of numerical and experimental studies.  

  10. Two component tungsten powder injection molding – An effective mass production process

    International Nuclear Information System (INIS)

    Antusch, Steffen; Commin, Lorelei; Mueller, Marcus; Piotter, Volker; Weingaertner, Tobias

    2014-01-01

    Tungsten and tungsten-alloys are presently considered to be the most promising materials for plasma facing components for future fusion power plants. The Karlsruhe Institute of Technology (KIT) divertor design concept for the future DEMO power plant is based on modular He-cooled finger units and the development of suitable mass production methods for such parts was needed. A time and cost effective near-net-shape forming process with the advantage of shape complexity, material utilization and high final density is Powder Injection Molding (PIM). This process allows also the joining of two different materials e.g. tungsten with a doped tungsten alloy, without brazing. The complete technological process of 2-Component powder injection molding for tungsten materials and its application on producing real DEMO divertor parts, characterization results of the finished parts e.g. microstructure, hardness, density and joining zone quality are discussed in this contribution

  11. Method for Converter Synchronization with RF Injection

    OpenAIRE

    Joshua P. Bruckmeyer; Ivica Kostanic

    2015-01-01

    This paper presents an injection method for synchronizing analog to digital converters (ADC). This approach can eliminate the need for precision routed discrete synchronization signals of current technologies, such as JESD204. By eliminating the setup and hold time requirements at the conversion (or near conversion) clock rate, higher sample rate systems can be synchronized. Measured data from an existing multiple ADC conversion system was used to evaluate the method. Coherent beams were simu...

  12. Intelligent methods for the process parameter determination of plastic injection molding

    Science.gov (United States)

    Gao, Huang; Zhang, Yun; Zhou, Xundao; Li, Dequn

    2018-03-01

    Injection molding is one of the most widely used material processing methods in producing plastic products with complex geometries and high precision. The determination of process parameters is important in obtaining qualified products and maintaining product quality. This article reviews the recent studies and developments of the intelligent methods applied in the process parameter determination of injection molding. These intelligent methods are classified into three categories: Case-based reasoning methods, expert system- based methods, and data fitting and optimization methods. A framework of process parameter determination is proposed after comprehensive discussions. Finally, the conclusions and future research topics are discussed.

  13. Cutaneous Side-effects of Immunomodulators in MS.

    Science.gov (United States)

    Lebrun, C; Bertagna, M; Cohen, M

    2011-09-01

    Local skin reactions to subcutaneous injections of interferon beta (IFNB) or glatiramer acetate (GA) in multiple sclerosis (MS) are frequent, while severe cutaneous toxicity is rare. Both IFNB and GA are immunomodulatory drugs that have excellent safety profiles and are currently used for treatment of MS. They are administered by SC injection every other day for IFNB-1b, three times a week for IFNB-1a or daily for 20 mg for GA. The most common adverse effects, which occur in approximately 20-60% of patients, include pain, inflammation and induration at the injection sites. Another adverse effect is frank panniculitis followed by localized lipoatrophy at the injection sites, which has been described in half of the patients receiving GA injections but is also described with Subcutaneous IFNB-1b. No guidelines have yet been established for the treatment of skin reactions, which is a frequent point for discussion between neurologists and dermatologists. In addition, no treatment has been found for established lipoatrophy. The prevention and management of cutaneous side-effects include patient education, regular examination and manual palpation of all injection sites. Non-steroid antiinflammatory gels, local corticosteroids or endermology can help patients to resolve side-effects and to continue immunomodulatory treatment.

  14. Wake structures of two side by side spheres in a tripped boundary layer flow

    Directory of Open Access Journals (Sweden)

    Canli Eyüb

    2014-03-01

    Full Text Available Two independent spheres were placed in a side by side arrangement and flow structure in the wake region of the spheres was investigated with a Particle Image Velocimetry (PIV system when the spheres were in a boundary layer over a flat plate as a special case. Reynolds number was 5000 based on the sphere diameter which was 42.5 mm. Boundary layer was tripped 8mm away from the leading edge of the flat plate with a 5 mm trip wire. The thickness of the hydrodynamically developed boundary layer was determined as 63mm which was larger than the sphere diameter of D=42.5mm. Wake region of the spheres was examined from point of flow physics for the different sphere locations in the ranges of 0≤G/D ≤1.5 and 0≤S/D ≤1.5 where G and S were the distance between the spheres and the distance between the bottom point of the spheres and the flat plate surface, respectively. Depending on the different sphere locations, instantaneous and time averaged vorticity data, scalar values of time-averaged velocity components and their root mean square (rms values and time averaged vorticity data are presented in the study for the evaluation of wake region of the spheres. It is demonstrated that the gap between the two spheres and the interaction between the gap and the boundary layer greatly affects flow pattern, especially when spheres are located near to the flat plate surface, i.e. S/D=0.1 for 0≤G/D ≤1.5. Different distances between the spheres resulted in various flow patterns as the spheres were approached to the flat plate. The distance S/D=0.1 for all gap values has the strongest effect on the wake structures. Beyond G/D=1.0, the sphere wakes tend to be similar to single sphere case. The instantaneous vorticity fields of the side by side arrangements comprised wavy structures in higher level comparing to an individual sphere case. The gap flow intensifies the occurrence of small scale eddies in the wake region. The submersion rate of the spheres

  15. Treatment of hyperfunctioning thyroid nodules by percutaneous ethanol injection

    Directory of Open Access Journals (Sweden)

    Sarai Maryam

    2002-12-01

    Full Text Available Abstract Background Autonomous thyroid nodules can be treated by a variety of methods. We assessed the efficacy of percutaneous ethanol injection in treating autonomous thyroid nodules. Methods 35 patients diagnosed by technetium-99 scanning with hyperfunctioning nodules and suppressed sensitive TSH (sTSH were given sterile ethanol injections under ultrasound guidance. 29 patients had clinical and biochemical hyperthyroidism. The other 6 had sub-clinical hyperthyroidism with suppressed sTSH levels (3, T4 and sTSH levels had returned to normal, or else injections could no longer be performed because significant side effects. Patients were followed up at 3, 6 and, in 15 patients, 24 months after the last injection. Results Average pre-treatment nodule volume [18.2 ± 12.7 ml] decreased to 5.7 ± 4.6 ml at 6 months follow-up [P 4 and sTSH did not change significantly between 6 months and 2 years [P > 0.05]. Ethanol injections were well tolerated by the patients, with only 2 cases of transient dysphonia. Conclusion Our findings indicate that ethanol injection is an alternative to surgery or radioactive iodine in the treatment of autonomous thyroid nodules.

  16. Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts

    Directory of Open Access Journals (Sweden)

    Poulikakos Dimos

    2007-09-01

    Full Text Available Abstract Purpose Coronary artery bypass graft (CABG surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences in the patency rates of the two types of anastomosis. The purpose of this paper is to non-invasively quantify hemodynamic parameters, such as mass flow and wall shear stress (WSS, in end-to-side and side-to-side anastomoses of patients with CABG using computational fluid dynamics (CFD. Methods One patient with saphenous CABG and end-to-side anastomosis and one patient with saphenous CABG and side-to-side anastomosis underwent 16-detector row computed tomography (CT. Geometric models of coronary arteries and bypasses were reconstructed for CFD analysis. Blood flow was considered pulsatile, laminar, incompressible and Newtonian. Peri-anastomotic mass flow and WSS were quantified and flow patterns visualized. Results CFD analysis based on in-vivo CT coronary angiography data was feasible in both patients. For both types of CABG, flow patterns were characterized by a retrograde flow into the native coronary artery. WSS variations were found in both anastomoses types, with highest WSS values at the heel and lowest WSS values at the floor of the end-to-side anastomosis. In contrast, the highest WSS values of the side-to-side anastomosis configuration were found in stenotic vessel segments and not in the close vicinity of the anastomosis. Flow stagnation zones were found in end-to-side but not in side-to-side anastomosis, the latter also demonstrating a smoother stream division throughout the cardiac cycle. Conclusion CFD analysis of venous CABG based on in-vivo CT datasets in patients was feasible producing qualitative and quantitative information on mass flow and WSS. Differences were found between the two types of anastomosis

  17. Assessing Unilateral Merger Effects in a Two-Sided Market : An Application to the Dutch Daily Newspaper Market

    NARCIS (Netherlands)

    Filistrucchi, L.; Klein, T.J.; Michielsen, T.O.

    2011-01-01

    We compare different methods to assess unilateral merger effects in a two-sided market by applying them to a hypothetical merger in the Dutch newspaper industry. For this, we first specify and estimate a structural model of demand for differentiated products on both the readership and the

  18. Accidental injections of dexamethasone intravitreal implant (Ozurdex) into the crystalline lens.

    Science.gov (United States)

    Coca-Robinot, Javier; Casco-Silva, Bruno; Armadá-Maresca, Felix; García-Martínez, Jesús

    2014-01-01

    To describe the side effects and management after inadvertent injection of a dexamethasone implant (Ozurdex) into the crystalline lens. Two case reports. Two patients with macular edema due to unilateral retinal vein occlusion were scheduled for an intravitreal injection of Ozurdex. During the procedure, the implant was accidentally injected into the crystalline lens. Both patients developed cataracts during the course of several weeks and in both there was an intraocular pressure (IOP) increase, which required treatment with topical hypotensives. Macular edema improved only slightly. Cataract surgery with uneventful removal of the implant was performed 3 (case 1) and 6 months (case 2) after the injection. After inadvertent injection of Ozurdex into the crystalline lens, cataract surgery with removal of the implant should be performed as soon as possible in order to avoid IOP increase and so that the underlying condition may be treated adequately.

  19. Downhole fluid injection systems, CO2 sequestration methods, and hydrocarbon material recovery methods

    Science.gov (United States)

    Schaef, Herbert T.; McGrail, B. Peter

    2015-07-28

    Downhole fluid injection systems are provided that can include a first well extending into a geological formation, and a fluid injector assembly located within the well. The fluid injector assembly can be configured to inject a liquid CO2/H2O-emulsion into the surrounding geological formation. CO2 sequestration methods are provided that can include exposing a geological formation to a liquid CO2/H2O-emulsion to sequester at least a portion of the CO2 from the emulsion within the formation. Hydrocarbon material recovery methods are provided that can include exposing a liquid CO2/H2O-emulsion to a geological formation having the hydrocarbon material therein. The methods can include recovering at least a portion of the hydrocarbon material from the formation.

  20. Electrokinetic sample preconcentration and hydrodynamic sample injection for microchip electrophoresis using a pneumatic microvalve.

    Science.gov (United States)

    Cong, Yongzheng; Katipamula, Shanta; Geng, Tao; Prost, Spencer A; Tang, Keqi; Kelly, Ryan T

    2016-02-01

    A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for zone electrophoresis using a single microvalve. The polydimethylsiloxane microchip comprises a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, serves as a nanochannel preconcentrator under an applied electric potential, enabling current to pass through while preventing bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected into the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ∼450 in 230 s. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high-resolution CE. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Stability of optically injected two-state quantum-dot lasers

    Energy Technology Data Exchange (ETDEWEB)

    Meinecke, Stefan; Lingnau, Benjamin; Roehm, Andre; Luedge, Kathy [Institut fuer Theoretische Physik, Technische Universitaet Berlin (Germany)

    2017-12-15

    Simultaneous two-state lasing is a unique property of semiconductor quantum-dot (QD) lasers. This not only changes steady-state characteristics of the laser device but also its dynamic response to perturbations. In this paper we investigate the dynamic stability of QD lasers in an external optical injection setup. Compared to conventional single-state laser devices, we find a strong suppression of dynamical instabilities in two-state lasers. Furthermore, depending on the frequency and intensity of the injected light, pronounced areas of bistability between both lasing frequencies appear, which can be employed for fast optical switching in all-optical photonic computing applications. These results emphasize the suitability of QD semiconductor lasers in future integrated optoelectronic systems where a high level of stability is required. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. Stability of optically injected two-state quantum-dot lasers

    International Nuclear Information System (INIS)

    Meinecke, Stefan; Lingnau, Benjamin; Roehm, Andre; Luedge, Kathy

    2017-01-01

    Simultaneous two-state lasing is a unique property of semiconductor quantum-dot (QD) lasers. This not only changes steady-state characteristics of the laser device but also its dynamic response to perturbations. In this paper we investigate the dynamic stability of QD lasers in an external optical injection setup. Compared to conventional single-state laser devices, we find a strong suppression of dynamical instabilities in two-state lasers. Furthermore, depending on the frequency and intensity of the injected light, pronounced areas of bistability between both lasing frequencies appear, which can be employed for fast optical switching in all-optical photonic computing applications. These results emphasize the suitability of QD semiconductor lasers in future integrated optoelectronic systems where a high level of stability is required. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Efficacy and safety of 10,600-nm carbon dioxide fractional laser on facial skin with previous volume injections

    Directory of Open Access Journals (Sweden)

    Josiane Hélou

    2013-01-01

    Full Text Available Background: Fractionated carbon dioxide (CO 2 lasers are a new treatment modality for skin resurfacing. The cosmetic rejuvenation market abounds with various injectable devices (poly-L-lactic acid, polymethyl-methacrylate, collagens, hyaluronic acids, silicone. The objective of this study is to examine the efficacy and safety of 10,600-nm CO 2 fractional laser on facial skin with previous volume injections. Materials and Methods: This is a retrospective study including 14 patients treated with fractional CO 2 laser and who have had previous facial volume restoration. The indication for the laser therapy, the age of the patients, previous facial volume restoration, and side effects were all recorded from their medical files. Objective assessments were made through clinical physician global assessment records and improvement scores records. Patients′ satisfaction rates were also recorded. Results: Review of medical records of the 14 patients show that five patients had polylactic acid injection prior to the laser session. Eight patients had hyaluronic acid injection prior to the laser session. Two patients had fat injection, two had silicone injection and one patient had facial thread lift. Side effects included pain during the laser treatment, post-treatment scaling, post-treatment erythema, hyperpigmentation which spontaneously resolved within a month. Concerning the previous facial volume restoration, no granulomatous reactions were noted, no facial shape deformation and no asymmetry were encountered whatever the facial volume product was. Conclusion: CO 2 fractional laser treatments do not seem to affect facial skin which had previous facial volume restoration with polylactic acid for more than 6 years, hyaluronic acid for more than 0.5 year, silicone for more than 6 years, or fat for more than 1.4 year. Prospective larger studies focusing on many other variables (skin phototype, injected device type are required to achieve better

  4. Design of Position Estimation Strategy of Sensorless Interior PMSM at Standstill Using Minimum Voltage Vector Injection Method

    DEFF Research Database (Denmark)

    Wu, Xuan; Huang, Shoudao; Liu, Xiao

    2017-01-01

    This paper presents a new initial rotor position estimation method for an interior permanent magnet synchronous motor. The proposed method includes two steps: firstly, the minimum voltage vectors are injected to estimate the rotor position. Secondly, in order to identify the magnet polarity...

  5. Testicular Busulfan Injection in Mice to Prepare Recipients for Spermatogonial Stem Cell Transplantation Is Safe and Non-Toxic.

    Science.gov (United States)

    Qin, YuSheng; Liu, Ling; He, YaNan; Wang, Chen; Liang, MingYuan; Chen, XiaoLi; Hao, HaiSheng; Qin, Tong; Zhao, XueMing; Wang, Dong

    2016-01-01

    Current methods of administering busulfan to remove the endogenous germ cells cause hematopoietic toxicity, require special instruments and a narrow transplantation time. We use a direct testicular injection of busulfan method for preparing recipients for SSC transplantation. Male ICR mice (recipients) were divided into four groups, and two experimental groups were treated with a bilateral testicular injection of 4 or 6 mg/kg/side busulfan (n = 60 per concentration group). Mice received an intraperitoneal injection (i.p.) of 40 mg/kg busulfan (n = 60, positive control) and bilateral testicular injections of 50% DMSO (n = 60, negative control). Donor SSCs from RFP-transgenic C57BL/6J mice were introduced into the seminiferous tubules of each recipient testis via efferent duct injection on day 16-17 after busulfan treatment. Recipient mice mated with mature female ICR mice and the number of progeny was recorded. The index detected at day 14, 21, 28, 35 and 70 after busulfan treatment. Blood analysis shows that the toxicity of busulfan treated groups was much lower than i.p. injection groups. Fertility was restored in mice treated with busulfan and donor-derived offspring were obtained after SSC transplantation. Our study indicated that intratesticular injection busulfan for the preparation of recipients in mice is safe and feasible.

  6. Testicular Busulfan Injection in Mice to Prepare Recipients for Spermatogonial Stem Cell Transplantation Is Safe and Non-Toxic.

    Directory of Open Access Journals (Sweden)

    YuSheng Qin

    Full Text Available Current methods of administering busulfan to remove the endogenous germ cells cause hematopoietic toxicity, require special instruments and a narrow transplantation time. We use a direct testicular injection of busulfan method for preparing recipients for SSC transplantation. Male ICR mice (recipients were divided into four groups, and two experimental groups were treated with a bilateral testicular injection of 4 or 6 mg/kg/side busulfan (n = 60 per concentration group. Mice received an intraperitoneal injection (i.p. of 40 mg/kg busulfan (n = 60, positive control and bilateral testicular injections of 50% DMSO (n = 60, negative control. Donor SSCs from RFP-transgenic C57BL/6J mice were introduced into the seminiferous tubules of each recipient testis via efferent duct injection on day 16-17 after busulfan treatment. Recipient mice mated with mature female ICR mice and the number of progeny was recorded. The index detected at day 14, 21, 28, 35 and 70 after busulfan treatment. Blood analysis shows that the toxicity of busulfan treated groups was much lower than i.p. injection groups. Fertility was restored in mice treated with busulfan and donor-derived offspring were obtained after SSC transplantation. Our study indicated that intratesticular injection busulfan for the preparation of recipients in mice is safe and feasible.

  7. Novice in Secondary School--The Coin Has Two Sides

    Science.gov (United States)

    Ulvik, Marit; Smith, Kari; Helleve, Ingrid

    2009-01-01

    The aim of this study is to gain an insight into novice teachers' diverse experiences. The study is conducted among nine beginning teachers in upper secondary school in Norway, and the research instrument was semi structured interviews. The main findings indicate that there are two sides of the coin of being a new teacher, positive as well as less…

  8. Detection of sentinel lymph nodes in cervical cancer. A comparison of two protocols

    International Nuclear Information System (INIS)

    Kraft, O.; Sevcik, L.; Klat, J.; Koliba, P.; Curik, R.; Kriozva, H.

    2006-01-01

    The aim of this study was lymphatic mapping to identify SLN in cervical cancer (CaCerv) with radioactive colloids, intraoperative detection with patent blue dye (PBD) and gamma probe (GP) and biopsy and comparison of two protocols. In 54 patients with CaCerv before hysterectomy and lymph nodes dissection (LND) we performed preoperative lymphoscintigraphy utilizing 99m Tc-colloid (Nanocoll, SentiScint or Nanocis), activity 40 MBq, on the operation day (30 women) or the day before operation (24 women). Gynaecologists injected 4 peritumoral injections of colloid into the cervix around the tumour. Scintigraphy followed 25-50 minutes (one-day protocol) or 12-19 hours (two-day protocol) after injection. Gynaecologists also injected 4 peritumoral injections of PBD into the cervix around the tumour. All women underwent SLN biopsy and LND (in average 35 lymph nodes were taken) and hysterectomy. SLNs (active and/or blue lymph nodes) were examined by a pathologist [histopathology and immunohistochemistry (IH) with detection of cytokeratine]. No SLN was examined without IH. The gynaecologists withdrew 123 SLNs (on average 2.27/1 patient) and in total 1898 lymph nodes (on average 35/1 patient). In 1 woman the tumour was inoperable. Two-day protocol, which involved scintigraphy, PBD and GP detected SLNs on both sides (45 SLNs) in 17 women (70.8%), SLNs on the one side (6 SLNs) in 3 patients (12.5%) and no SLNs were found in 4 women (16.7%). One-day protocol detected SLNs on both sides in 23 patients (74.1%) - 63 SLNs, in 7 women on one side (25.9%) - 9 SLNs. Metastases in SLNs (with or without metastases in other LN) were found in 21 patients (38.9%) - in 1 woman of stage FIGO IB1, in 1 woman of stage FIGO IB2, in 1 patient of stage FIGO IIIA and in all 18 patients of stage FIGO IIIB. False negative SLN detection was 0%. In SLN detection in patients with CaCerv, all 3 methods - scintigraphy, PBD and GP - should be used, and the success rate of SLN detection increases, although

  9. Isolated left-sided pulmonary artery agenesis with left lung hypoplasia: A report of two cases

    Directory of Open Access Journals (Sweden)

    V Govindaraj

    2017-01-01

    Full Text Available Unilateral absence of pulmonary artery or pulmonary artery agenesis (UAPA is a rare congenital malformation that can present as an isolated lesion or in association with other cardiac anomalies. Though congenital, presentation in adults are also reported. Most common presentation in adults is of exercise intolerance. The developing lung on the affected side is hypoplastic. Diagnosis of UAPA is established by imaging methods like CT and MRI . There is no specific treatment for this condition. Treatment depends on patients symptomatology, presence of pulmonary hypertension and collateral circulation. Presence of pulmonary hypertension carries a bad prognosis. We present two adult patients with isolated left sided unilateral pulmonary artery agenesis with ipsilateral lung hypoplasia. The diagnosis was confirmed by CT chest and perfusion scan.

  10. Wavelength switching dynamics of two-colour semiconductor lasers with optical injection and feedback

    International Nuclear Information System (INIS)

    Osborne, S; Heinricht, P; Brandonisio, N; Amann, A; O’Brien, S

    2012-01-01

    The wavelength switching dynamics of two-colour semiconductor lasers with optical injection and feedback are presented. These devices incorporate slotted regions etched into the laser ridge waveguide for tailoring the output spectrum. Experimental measurements are presented demonstrating that optical injection in one or both modes of these devices can induce wavelength bistability. Measured switching dynamics with modulated optical injection are shown to be in excellent agreement with numerical simulations based on a simple rate equation model. We also demonstrate experimentally that time-delayed optical feedback can induce wavelength bistability for short external cavity lengths. Numerical simulations indicate that this two-colour optical feedback system can provide fast optical memory functionality based on injected optical pulses without the need for an external holding beam. (paper)

  11. Two Component Injection Moulding for Moulded Interconnect Devices

    DEFF Research Database (Denmark)

    Islam, Aminul

    component (2k) injection moulding is one of the most industrially adaptive processes. However, the use of two component injection moulding for MID fabrication, with circuit patterns in sub-millimeter range, is still a big challenge. This book searches for the technical difficulties associated...... with the process and makes attempts to overcome those challenges. In search of suitable polymer materials for MID applications, potential materials are characterized in terms of polymer-polymer bond strength, polymer-polymer interface quality and selective metallization. The experimental results find the factors...... which can effectively control the quality of 2k moulded parts and metallized MIDs. This book presents documented knowledge about MID process chains, 2k moulding and selective metallization which can be valuable source of information for both academic and industrial users....

  12. SQL Injection Attacks and Defense

    CERN Document Server

    Clarke, Justin

    2012-01-01

    SQL Injection Attacks and Defense, First Edition: Winner of the Best Book Bejtlich Read Award "SQL injection is probably the number one problem for any server-side application, and this book unequaled in its coverage." -Richard Bejtlich, Tao Security blog SQL injection represents one of the most dangerous and well-known, yet misunderstood, security vulnerabilities on the Internet, largely because there is no central repository of information available for penetration testers, IT security consultants and practitioners, and web/software developers to turn to for help. SQL Injection Att

  13. Process Condition Monitoring of Micro Moulding Using a Two-plunger Micro Injection Moulding Machine

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Guerrier, Patrick

    2010-01-01

    The influence of micro injection moulding (µIM) process parameters (melt and mould temperature, piston injection speed and stoke length) on the injection pressure was investigated using Design of Experiments. Direct piston injection pressure measurements were performed and data collected using...... a micro injection moulding machine equipped with a two-pluger injection unit. Miniaturized dog-bone shaped speciments on polyoxymethylene (POM) were moulded over a wide range of processing cpnditions in order to characterize the process and assess its capability. Experimental results obtained under...

  14. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  15. Study on scan timing using a test injection method in head CTA

    International Nuclear Information System (INIS)

    Sekito, Yuichi; Sanada, Hidenori

    2005-01-01

    In head computed tomographic angiography (CTA), circulation from arterial phase to venous phase is more rapid than that in other regions. Therefore, it is necessary to determine correct scan timing to obtain ideal CTA images. A test injection method makes it possible to set correct scan timing from the time density curve (TDC) for each subject. The method, however, has a weak point that is a time lag in an arrival time at peak point of contrast medium on TDC between the test injection and the primary examination because of the difference in total volume of contrast medium used. The purpose of this study calculated the delay time on the TDC in both scans. We used the test injection method and the bolus tracking method in the primary examination. The average errors in start time (Δt1) and slope change time (Δt2) of the contrast medium on the TDC between test injection and primary examination were 0.15 sec and 3.05 sec, respectively. The results indicated that it was important to grasp the delay time in start time and peak arrival time of the contrast medium between test injection and primary examination to obtain ideal images in head CTA. (author)

  16. Comparative study of the novel and conventional injection approach for inferior alveolar nerve block.

    Science.gov (United States)

    Boonsiriseth, K; Sirintawat, N; Arunakul, K; Wongsirichat, N

    2013-07-01

    This study aimed to evaluate the efficacy of anesthesia obtained with a novel injection approach for inferior alveolar nerve block compared with the conventional injection approach. 40 patients in good health, randomly received each of two injection approaches of local anesthetic on each side of the mandible at two separate appointments. A sharp probe and an electric pulp tester were used to test anesthesia before injection, after injection when the patients' sensation changed, and 5 min after injection. This study comprised positive aspiration and intravascular injection 5% and neurovascular bundle injection 7.5% in the conventional inferior alveolar nerve block, but without occurrence in the novel injection approach. A visual analog scale (VAS) pain assessment was used during injection and surgery. The significance level used in the statistical analysis was pinferior alveolar nerve block by the novel injection approach provided adequate anesthesia and caused less pain and greater safety during injection. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Process control and product evaluation in micro molding using a screwless/two-plunger injection unit

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Dormann, B.

    2010-01-01

    A newly developed μ-injection molding machine equipped with a screwless/two-plunger injection unit has been employed to mould miniaturized dog-bone shaped specimens on polyoxymethylene and its process capability and robustness have been analyzed. The influence of process parameters on μ-injection......A newly developed μ-injection molding machine equipped with a screwless/two-plunger injection unit has been employed to mould miniaturized dog-bone shaped specimens on polyoxymethylene and its process capability and robustness have been analyzed. The influence of process parameters on μ......-injection molding was investigated using the Design of Experiments technique. Injection pressure and piston stroke speed as well as part weight and dimensions were considered as quality factors over a wide range of process parameters. Experimental results obtained under different processing conditions were...

  18. A simple method of injecting tumescent fluid for liposuction

    Directory of Open Access Journals (Sweden)

    Arindam Sarkar

    2011-01-01

    Full Text Available Injection of tumescent fluid is essential to obtain a painless and relatively bloodless liposuction. There are many methods of injecting the tumescent fluid like power pumps, syringes and pressure cuffs. Our method consists of applying air pressure within the plastic transfusion fluid bottle by pricking with a wide bore needle and connecting it to a sphygmomanometer balloon pump. By inflation of the balloon pump and thus increasing pressure inside the plastic bottle, the rate and volume of infusion can be controlled. By applying the cuff outside the bottle the visibility inside is impaired and the bottle gets collapsed preventing a continued pressure and thereby impairing both the quantity as well as the rate of infusion. Power pumps are expensive. This method is inexpensive, infused volume of fluid being visible and the rate of infusion controllable.

  19. Current control methods for grid-side three-phase PWM voltage-source inverter in distributed generation systems

    DEFF Research Database (Denmark)

    Lar, Ionut Andrei; Radulescu, Mircea; Ritchie, Ewen

    2012-01-01

    A comparison between two current control methods of grid side inverter, PI current control and Robust Forward control is made. PI control is implemented in d-q synchronous frame while Forward is implemented in abc stationary frames.The report contains both simulations and experimental test wich...

  20. Estimating the number of HIV-infected injection drug users in Bangkok: a capture--recapture method.

    Science.gov (United States)

    Mastro, T D; Kitayaporn, D; Weniger, B G; Vanichseni, S; Laosunthorn, V; Uneklabh, T; Uneklabh, C; Choopanya, K; Limpakarnjanarat, K

    1994-07-01

    The purpose of the study was to estimate the number of injection drug users infected with the human immunodeficiency virus (HIV) in Bangkok to allow planning for health services for this population. A two-sample capture-recapture method was used. The first capture listed all persons on methadone treatment for opiate addiction from April 17 through May 17, 1991, at 18 facilities in Bangkok. The second capture involved urine testing of persons held at 72 Bangkok police stations from June 3 through September 30, 1991. Persons whose urine tests were positive for opiate metabolites or methadone were included on the second list. The first capture comprised 4064 persons and the recapture 1540 persons. There were 171 persons included on both lists, yielding an estimate of 36,600 opiate users in Bangkok. Existing data indicate that 89% of opiate users in Bangkok inject drugs and that about one third are infected with HIV, yielding an estimate of approximately 12,000 HIV-infected injection drug users in Bangkok in 1991. During the 1990s the number of cases of acquired immunodeficiency syndrome (AIDS) and other HIV-related diseases, including tuberculosis, in the population of HIV-infected injection drug users in Bangkok will increase dramatically, placing new demands on existing health care facilities. The capture-recapture method may be useful in estimating difficult-to-count populations, including injection drug users.

  1. [Comparative study on four kinds of assessment methods of post-marketing safety of Danhong injection].

    Science.gov (United States)

    Li, Xuelin; Tang, Jinfa; Meng, Fei; Li, Chunxiao; Xie, Yanming

    2011-10-01

    To study the adverse reaction of Danhong injection with four kinds of methods, central monitoring method, chart review method, literature study method and spontaneous reporting method, and to compare the differences between them, explore an appropriate method to carry out post-marketing safety evaluation of traditional Chinese medicine injection. Set down the adverse reactions' questionnaire of four kinds of methods, central monitoring method, chart review method, literature study method and collect the information on adverse reactions in a certain period. Danhong injection adverse reaction information from Henan Province spontaneous reporting system was collected with spontaneous reporting method. Carry on data summary and descriptive analysis. Study the adverse reaction of Danhong injection with four methods of central monitoring method, chart review method, literature study method and spontaneous reporting method, the rates of adverse events were 0.993%, 0.336%, 0.515%, 0.067%, respectively. Cyanosis, arrhythmia, hypotension, sweating, erythema, hemorrhage dermatitis, rash, irritability, bleeding gums, toothache, tinnitus, asthma, elevated aminotransferases, constipation, pain are new discovered adverse reactions. The central monitoring method is the appropriate method to carry out post-marketing safety evaluation of traditional Chinese medicine injection, which could objectively reflect the real world of clinical usage.

  2. A method for the investigation of cholegraphic contrast media

    International Nuclear Information System (INIS)

    Otto, H.

    1982-01-01

    Isolated perfused rat livers were used for investigating possible interactions between two simultaneously injected contrast media, and which technique, using parenteral application of cholegraphic media, is optimal. The results show that excretion of a parenteral contrast medium is reduced by giving an oral contrast medium at the same time. Simultaneous administration of two different contrast media therefore does not result in improved diagnostic information. The effect depends on the dose, and a sufficiently long interval should be observed between giving an oral and a parenteral contrast medium. A comparison of excretion values following injection of a bolus and prolonged infusion shows higher biliary contrast concentration and increased excretion after a single injection. Comparing only the period after the infusion, no difference was found between these two methods of administration. The single injection offers pharmacokinetic advantages, but an infusion is better tolerated and has fewer side effects. A rapid infusion of 10 to 15 minutes is therefore recommended as the optimal means of administration. (orig.) [de

  3. Comparing Two Methods of Cryotherapy and Intense Pulsed Light with Triamcinolone Injection in the Treatment of Keloid and Hypertrophic Scars: A Clinical Trial.

    Science.gov (United States)

    Meymandi, Simin Shamsi; Moosazadeh, Mahmood; Rezazadeh, Azadeh

    2016-10-01

    Keloid and hypertrophic scars are abnormal manifestations of wounds that occur following skin injuries in the form of local proliferation of fibroblasts and increased production of collagen. There are several ways to cure these scars; treatment must be selected based on the nature of the scars. In this clinical trial, two methods-cryotherapy and intense pulsed light (IPL)-are compared in the treatment of scars, and the results are presented in terms of improvement level, complications, and patient satisfaction. This clinical trial was conducted in southeastern Iran. The intervention group included scars that underwent the IPL method and the control group, which consisted of scars that were subjected to cryotherapy. In both methods, intralesional corticosteroid injection was administered. To select samples, the easy sampling method was used. To determine the expected outcomes, the criteria determined in the Vancouver scar scale were used. Data were analyzed using the Mix Model, chi-square test, and t test. In this study, 166 samples of keloid and hypertrophic scars were cured using two methods (Cryotherapy, 83; IPL, 83). The recovery rate was higher in the Cryotherapy group than in the IPL group ( p  > 0.05), and the incidence of complications was also higher in the Cryotherapy group (14.5% vs. 12%). Moreover, patients were more satisfied, although not significantly so, with the cryotherapy method ( p  = 0.09). Both methods were highly successful in curing scars; participants were totally satisfied with both methods.

  4. Assessment methods of injection moulded nano-patterned surfaces

    DEFF Research Database (Denmark)

    Menotti, S.; Bisacco, G.; Hansen, H. N.

    2014-01-01

    algorithm for feature recognition. To compare the methods, the mould insert and a number of replicated nano-patterned surfaces, injection moulded with an induction heating aid, were measured on nominally identical locations by means of an atomic force microscope mounted on a manual CMM....

  5. Autologous Fat Injection for Augmented Mammoplasty

    International Nuclear Information System (INIS)

    Yoon, Eul Sik; Seo, Bo Kyoung; Yi, Ann; Cho, Kyu Ran

    2008-01-01

    Autologous fat injection is one of the methods utilized for augmented mammoplasty methods. In this surgical procedure, the fat for transfer is obtained from the donor site of the patient's own body by liposuction and the fat is then injected into the breast. We report here cases of three patients who underwent autologous fat injection. Two of the patients had palpable masses that were present after surgery. The serial imaging findings and surgical method of autologous fat transfer are demonstrated

  6. Therapeutic hip injections: Is the injection volume important?

    International Nuclear Information System (INIS)

    Young, R.; Harding, J.; Kingsly, A.; Bradley, M.

    2012-01-01

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  7. Therapeutic hip injections: Is the injection volume important?

    Energy Technology Data Exchange (ETDEWEB)

    Young, R., E-mail: russell.young@gwh.nhs.uk [Department of Radiology, Great Western Hospital, Swindon (United Kingdom); Harding, J. [Department of Radiology, University Hospital Coventry, Coventry (United Kingdom); Kingsly, A. [Department of Mathematics and Statistics, Bristol Institue of Technology, University of the West of England, Bristol (United Kingdom); Bradley, M. [Department of Radiology, Southmead Hospital, Bristol (United Kingdom)

    2012-01-15

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  8. Inner centering in parting line area of injection mould using side locks

    DEFF Research Database (Denmark)

    Mahshid, Rasoul; Hansen, Hans Nørgaard

    2017-01-01

    Injection moulding is characterized by high precision requirements. In particular, the demands regarding the mould plates alignment are in order of few micro meters. This research introduces a methodology to measure the misalignment in injection moulding. Eddy current sensors are used in the system...

  9. Modern Cored Wire Injection 2PE-9 Method in the Production of Ductile Iron

    Directory of Open Access Journals (Sweden)

    E. Guzik

    2012-04-01

    Full Text Available The results of studies on the use of modern two cored wires injection method for production of nodular graphite cast iron with use of unique implementation of drum ladle as a treatment/ transport and casting ladle instead vertical treatment ladle was described. The injection of length of Ø 9mm wires, cored: in FeSi + Mg nodulariser mixture and inoculant master alloy is a treatment method which can be used to produce iron melted in coreless induction furnace. This paper describes the results of using this method for possibility production of ductile iron under specific industrial conditions. In this case was taken ductile iron with material designation: EN-GJS-450- 10 Grade according PN-EN 1563:2000. Microstructure of 28 trials was controlled on internally used sample which has been correlated with standard sample before. The paper presents typical metallic matrix and graphite characteristic. Additionally, mechanical properties were checked in one experiment. Because of further possibility treatment temperature reduction only the rough magnesium recovery and cost of this new method are given.

  10. 125I-labelled botulinum A neurotoxin: pharmacokinetics in cats after intramuscular injection

    International Nuclear Information System (INIS)

    Wiegand, H.; Erdmann, G.; Wellhoener, H.H.

    1976-01-01

    On unilateral injection of sublethal doses of 125 I-botulinum A neurotoxin (BTA) into one gastrocnemius muscle of the cat we found after 48 h: a disto-proximal gradient of radioactivity (RA) hat developed in the sciatic nerve of the injected side. The ventral roots of the spinal cord half segments supplying the injected muscle showed a higher RA than the ventral roots of the contralateral control side. The spinal cord half segments innervating the injected muscle had a RA much higher than the corresponding segments of the contralateral side. However, a small rise of RA was also observed in the contralateral half segments. In histoautoradiographs of the (ligatured) ventral roots the RA was strictly confined to the intraaxonal space of a few nerve fibres. On injection of equal doses of 125 I-BTA into either gastrocnemius muscle we found after 38 h: direct stimulation of only one of the injected muscles caused the RA to reach a higher level in the spinal cord half segments ipsilateral to the stimulated muscle than in the spinal cord half segments of the non-stimulated side. Unilateral stimulation of one gastrocnemius nerve under the influence of gallamine or unilateral antidromic stimulation of the dorsal roots L7, S1 failed to cause a difference in RA between stimulated and non-stimulated side. (orig.) [de

  11. Short-term muscle atrophy caused by botulinum toxin-A local injection impairs fracture healing in the rat femur.

    Science.gov (United States)

    Hao, Yongqiang; Ma, Yongcheng; Wang, Xuepeng; Jin, Fangchun; Ge, Shengfang

    2012-04-01

    Damaged bone is sensitive to mechanical stimulation throughout the remodeling phase of bone healing. Muscle damage and muscular atrophy associated with open fractures and subsequent fixation are not beneficial to maintaining optimum conditions for mechanical stability. The aim of this study was to investigate whether local muscle atrophy and dysfunction affect fracture healing in a rat femur fracture model. We combined the rat model of a short period atrophy of the quadriceps with femur fracture. Forty-four-month-old male Wistar rats were adopted for this study. Two units of botulinum toxin-A (BXTA) were administered locally into the right side of the quadriceps of each rat, while the same dose of saline was injected into the contralateral quadriceps. After BXTA had been fully absorbed by the quadriceps, osteotomy was performed in both femurs with intramedullary fixation. Gross observation and weighing of muscle tissue, X-ray analysis, callus histology, and bone biomechanical testing were performed at different time points up to 8 weeks post-surgery. Local injection of BXTA led to a significant decrease in the volume and weight of the quadriceps compared to the control side. At the eighth week, the left side femurs of the saline-injected quadriceps almost reached bony union, and fibrous calluses were completely calcified into woven bone. However, a gap was still visible in the BXTA-treated side on X-ray images. As showed by bone histology, there were no mature osseous calluses or woven bone on the BXTA-treated side, but a resorption pattern was evident. Biomechanical testing indicated that the femurs of the BXTA-treated side exhibited inferior mechanical properties compared with the control side. The inferior outcome following BXTA injection, compared with saline injection, in terms of callus resistance may be the consequence of unexpected load and mechanical unsteadiness caused by muscle atrophy and dysfunction. Copyright © 2011 Orthopaedic Research Society.

  12. Side effects during subcutaneous immunotherapy in children with allergic diseases.

    Science.gov (United States)

    Tophof, Max A; Hermanns, Anne; Adelt, Thomas; Eberle, Peter; Gronke, Christine; Friedrichs, Frank; Knecht, Roland; Mönter, Ernst; Schöpfer, Helmut; Schwerk, Nicolaus; Steinbach, Jörg; Umpfenbach, Hans-Ulrich; Weißhaar, Christian; Wilmsmeyer, Brigitte; Bufe, Albrecht

    2018-05-01

    Allergen-specific immunotherapy is the only causal form of therapy for IgE-mediated allergic diseases. Subcutaneous immunotherapy (SCIT) is considered safe and well tolerated in adults, yet there is less evidence of safety in the pediatric population. A non-interventional prospective observing longitudinal study was carried out to determine the incidence of local and systemic side effects by SCIT, routinely performed in pediatric patients. A total of 581 pediatric patients were observed in 18 study centers between March 2012 and October 2014, recording 8640 treatments and 10 015 injections. A total of 54.6% of the patients experienced immediate local side effects at least once; delayed local side effects were seen in 56.1%. Immediate systemic adverse reactions occurred in 2.2% of patients; 7.4% experienced delayed systemic side effects. However, severe systemic side effects (grade III in the classification of Ring and Messmer) were seen in 0.03% of all treatments, all appearing within 30 minutes after the injections. No grade IV reactions were observed. In addition, many potential risk factors were investigated, yet only a few were found to be associated with the occurrence of side effects. Subcutaneous immunotherapy is a safe form of therapy in pediatric patients, with similar rates of local side effects compared to adult patients and low rates of severe systemic side effects. However, local and systemic reactions occurring later than 30 minutes after injection were observed more often than expected, which makes it essential to be attentive on behalf of pediatricians, patients, and parents. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  13. Statistical Significance and Effect Size: Two Sides of a Coin.

    Science.gov (United States)

    Fan, Xitao

    This paper suggests that statistical significance testing and effect size are two sides of the same coin; they complement each other, but do not substitute for one another. Good research practice requires that both should be taken into consideration to make sound quantitative decisions. A Monte Carlo simulation experiment was conducted, and a…

  14. Cellulitis Developing After Intramuscular Metamizole Injection

    Directory of Open Access Journals (Sweden)

    Onur Ozturk

    2016-12-01

    Full Text Available If the suitable technique is not used in intramuscular injection applications and the injection area is not detected correctly, complications may be observed. Our patient was given intramuscular Metamizole in his house and then he had cellulitis with necrosis area. Following an antibiotic treatment, tissue defect was primarily covered with gluteal muscle skin flap. Cellulitis development after metamizole injection is not common still potential side effects should be considered before prescription.

  15. Two-step impression/ injection, an alternative putty/ wash impression technique: case report.

    Science.gov (United States)

    Caputi, S; Murmura, G; Sinjari, B; Varvara, G

    2012-01-01

    We here describe a new technique for making a definitive impression that we refer to as the two-step impression/injection technique. This technique initially follows the classical one-step putty/ light-body impression technique with the polymerization of the putty and the light-body compound. This is then followed by the second step: injection of extra-light-body compound into the preparation through a hole in the metal stock tray. The aim of this additional step is to control the wash bulk and minimize the changes that can produce unfavorable impression results. This new two-step impression/injection technique allows displacement of soft tissues, such as the tongue, during the first seating of the putty and wash materials, while in the second step, the extra-light-body compound records all of the finer details without being compressed.

  16. On revenue and welfare dominance of ad valorem taxes in two-sided markets

    DEFF Research Database (Denmark)

    Kind, Hans Jarle; Köthenbürger, Marko; Schjelderup, Guttorm

    2009-01-01

    A benchmark result in public economics is that it is possible to increase both tax revenue and welfare by making a monopoly subject to ad valorem taxes rather than unit taxes. We show that such revenue and welfare dominance does not hold in two-sided markets.......A benchmark result in public economics is that it is possible to increase both tax revenue and welfare by making a monopoly subject to ad valorem taxes rather than unit taxes. We show that such revenue and welfare dominance does not hold in two-sided markets....

  17. Rheological and thermal analysis of the filling stage of injection moulding

    Directory of Open Access Journals (Sweden)

    A. Szucs

    2012-08-01

    Full Text Available Flow conditions are different in the cavity of the injection mould from the capillary flow of a laboratory rheological instrument. An injection moulding slit die rheometer (Rheo-mould was designed with a series of slit and orifice dies. Four pressure sensors were built in the stationary side of the mould, therefore the pressure could be measured at four different places. A changeable slit die insert was designed in the moving side. The shear stress and the shear rate can be calculated from the pressure gradient and from the flow rate of the melt, respectively. Flow curves of low density polyethylene were determined using Bagley, Rabinowitsch and Mooney corrections. The results were compared to the flow curves determined by Göttfert and Haake capillary equipments. It was found that the agreement between the methods is excellent.

  18. Rational Arithmetic Mathematica Functions to Evaluate the Two-Sided One Sample K-S Cumulative Sampling Distribution

    Directory of Open Access Journals (Sweden)

    J. Randall Brown

    2007-06-01

    Full Text Available One of the most widely used goodness-of-fit tests is the two-sided one sample Kolmogorov-Smirnov (K-S test which has been implemented by many computer statistical software packages. To calculate a two-sided p value (evaluate the cumulative sampling distribution, these packages use various methods including recursion formulae, limiting distributions, and approximations of unknown accuracy developed over thirty years ago. Based on an extensive literature search for the two-sided one sample K-S test, this paper identifies an exact formula for sample sizes up to 31, six recursion formulae, and one matrix formula that can be used to calculate a p value. To ensure accurate calculation by avoiding catastrophic cancelation and eliminating rounding error, each of these formulae is implemented in rational arithmetic. For the six recursion formulae and the matrix formula, computational experience for sample sizes up to 500 shows that computational times are increasing functions of both the sample size and the number of digits in the numerator and denominator integers of the rational number test statistic. The computational times of the seven formulae vary immensely but the Durbin recursion formula is almost always the fastest. Linear search is used to calculate the inverse of the cumulative sampling distribution (find the confidence interval half-width and tables of calculated half-widths are presented for sample sizes up to 500. Using calculated half-widths as input, computational times for the fastest formula, the Durbin recursion formula, are given for sample sizes up to two thousand.

  19. Flow visualization and simulation of the filling process during injection molding

    DEFF Research Database (Denmark)

    Guerrier, Patrick; Tosello, Guido; Hattel, Jesper Henri

    2017-01-01

    To directly compare experimental moldings from an injection molding machine with simulations, a special mold has been produced with a glass window. The injection plane is perpendicular to the opening and closing planes, in order for the 55. mm thick glass window to be easily visible from the side....... These two had significant effects on the filling times and injection pressure calculated by the simulations. Other effects investigated included transient thermal management of the mold, pressure dependent viscosity and wall slip, but their effect were not remarkably large in this work. The obtained....... A high speed camera recording 500 frames per second was employed, and the mold had three thermocouples and two pressure sensors installed. The molded part is a 2. mm thick plate with a 0.5. mm thin section, which creates a characteristic V-shaped flow pattern. Two different materials were employed...

  20. Simulation bidimensional of water and gas alternative injection; Simulacao bidimensional de injecao alternada de agua e gas

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Ana Paula Silva C. de

    1999-07-01

    This dissertation presents a study of the unidimensional of water and gas alternate injection (WAG) using the stream line theory. It is considered incompressible fluid., unit mobility ratio, negligible capillary and gravitational effects, homogeneous and isotropic reservoir, isothermal flow two phases, oil and water, and three components, oil, water and gas. In the stream line theory, the following injection schemes are considered: staggered line five-spot, direct line and seven-spot. It is also considered that there is no flow among the streams. In the WAG calculations it is used the fractional flow theory and the method of characteristics, which consists of shock waves and rarefactions. The composition of these waves is said compatible if it satisfies the entropy condition. The solution goes through a certain path from the left to the right side constrained by the initial and boundary conditions. The gas injection is at a high pressure to ensure miscible displacement. It is considered first injection of a water bank and then, injection of a gas bank. We concluded that the gas injection at a high pressure recoveries all residual oil and the water saturation remains is greater than initial saturation. (author)

  1. Optimal Sample Size Determinations for the Heteroscedastic Two One-Sided Tests of Mean Equivalence: Design Schemes and Software Implementations

    Science.gov (United States)

    Jan, Show-Li; Shieh, Gwowen

    2017-01-01

    Equivalence assessment is becoming an increasingly important topic in many application areas including behavioral and social sciences research. Although there exist more powerful tests, the two one-sided tests (TOST) procedure is a technically transparent and widely accepted method for establishing statistical equivalence. Alternatively, a direct…

  2. Calculation methods for single-sided natural ventilation - simplified or detailed?

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Plesner, Christoffer; Leprince, Valérie

    2016-01-01

    A great energy saving potential lies within increased use of natural ventilation, not only during summer and midseason periods, where it is mainly used today, but also during winter periods, where the outdoor air holds a great cooling potential for ventilative cooling if draft problems can...... be handled. This paper presents a newly developed simplified calculation method for single-sided natural ventilation, which is proposed for the revised standard FprEN 16798-7 (earlier EN 15242:2007) for design of ventilative cooling. The aim for predicting ventilative cooling is to find the most suitable......, while maintaining an acceptable correlation with measurements on average and the authors consider the simplified calculation method well suited for the use in standards such as FprEN 16798-7 for the ventilative cooling effects from single-sided natural ventilation The comparison of different design...

  3. MODELING OF ELECTRONIC GASOLINE INJECTION PROCESSES IN TWO STROKE ENGINE

    Directory of Open Access Journals (Sweden)

    Hraivoronskyi, Y.

    2013-06-01

    Full Text Available Basic provision of the processes developed mode, occurring in ignition fuel system with electronically controlled two stroke engine with positive ignition are given. Fuel injection process’ calculation results for the case of placing fuel injector into intake system presented.

  4. /sup 125/I-labelled botulinum A neurotoxin: pharmacokinetics in cats after intramuscular injection

    Energy Technology Data Exchange (ETDEWEB)

    Wiegand, H; Erdmann, G; Wellhoener, H H [Giessen Univ. (Germany, F.R.). Pharmakologisches Inst.

    1976-01-01

    On unilateral injection of sublethal doses of /sup 125/I-botulinum A neurotoxin (BTA) into one gastrocnemius muscle of the cat we found after 48 h: a disto-proximal gradient of radioactivity (RA) hat developed in the sciatic nerve of the injected side. The ventral roots of the spinal cord half segments supplying the injected muscle showed a higher RA than the ventral roots of the contralateral control side. The spinal cord half segments innervating the injected muscle had a RA much higher than the corresponding segments of the contralateral side. However, a small rise of RA was also observed in the contralateral half segments. In histoautoradiographs of the (ligatured) ventral roots the RA was strictly confined to the intraaxonal space of a few nerve fibres. On injection of equal doses of /sup 125/I-BTA into either gastrocnemius muscle we found after 38 h: direct stimulation of only one of the injected muscles caused the RA to reach a higher level in the spinal cord half segments ipsilateral to the stimulated muscle than in the spinal cord half segments of the non-stimulated side. Unilateral stimulation of one gastrocnemius nerve under the influence of gallamine or unilateral antidromic stimulation of the dorsal roots L7, S1 failed to cause a difference in RA between stimulated and non-stimulated side.

  5. A method of adjusting SUV for injection-acquisition time differences in {sup 18}F-FDG PET Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Laffon, Eric [Hopital du Haut Leveque, CHU de Bordeaux, Pessac (France); Centre de Recherche Cardio-Thoracique, Bordeaux (France); Hopital du Haut-Leveque, Service de Medecine Nucleaire, Pessac (France); Clermont, Henri de [Hopital du Haut Leveque, CHU de Bordeaux, Pessac (France); Marthan, Roger [Hopital du Haut Leveque, CHU de Bordeaux, Pessac (France); Centre de Recherche Cardio-Thoracique, Bordeaux (France)

    2011-11-15

    A time normalisation method of tumour SUVs in {sup 18}F-FDG PET imaging is proposed that has been verified in lung cancer patients. A two-compartment model analysis showed that, when SUV is not corrected for {sup 18}F physical decay (SUV{sub uncorr}), its value is within 5% of its peak value (t = 79 min) between 55 and 110 min after injection, in each individual patient. In 10 patients, each with 1 or more malignant lesions (n = 15), two PET acquisitions were performed within this time delay, and the maximal SUV of each lesion, both corrected and uncorrected, was assessed. No significant difference was found between the two uncorrected SUVs, whereas there was a significant difference between the two corrected ones: mean differences were 0.04 {+-} 0.22 and 3.24 {+-} 0.75 g.ml{sup -1}, respectively (95% confidence intervals). Therefore, a simple normalisation of decay-corrected SUV for time differences after injection is proposed: SUV{sub N} = 1.66*SUV{sub uncorr}, where the factor 1.66 arises from decay correction at t = 79 min. When {sup 18}F-FDG PET imaging is performed within the range 55-110 min after injection, a simple SUV normalisation for time differences after injection has been verified in patients with lung cancer, with a {+-}2.5% relative measurement uncertainty. (orig.)

  6. Comparison of zero-sequence injection methods in cascaded H-bridge multilevel converters for large-scale photovoltaic integration

    DEFF Research Database (Denmark)

    Yu, Yifan; Konstantinou, Georgios; Townsend, Christopher David

    2017-01-01

    to maintain three-phase balanced grid currents with unbalanced power generation. This study theoretically compares power balance capabilities of various zero-sequence injection methods based on two metrics which can be easily generalised for all CHB applications to PV systems. Experimental results based......Photovoltaic (PV) power generation levels in the three phases of a multilevel cascaded H-bridge (CHB) converter can be significantly unbalanced, owing to different irradiance levels and ambient temperatures over a large-scale solar PV power plant. Injection of a zero-sequence voltage is required...... on a 430 V, 10 kW, three-phase, seven-level cascaded H-bridge converter prototype confirm superior performance of the optimal zero-sequence injection technique....

  7. 3D MHD simulations of pellet injection and disruptions in tokamak plasmas

    International Nuclear Information System (INIS)

    Strauss, H.R.; Park, W.; Belova, E.; Fu, G.Y.; Sugiyama, L.E.

    2001-01-01

    Nonlinear MHD simulation results of pellet injection show that MHD forces can accelerate large pellets, injected on the high field side of a tokamak, to the plasma center. Magnetic reconnection can produce a reverse shear q profile. Ballooning instability caused by pellets is also reduced by high field side injection. Studies are also reported of the current quench phase of disruptions, which can cause 3D halo currents and runaway electrons. (author)

  8. 3D MHD simulations of pellet injection and disruptions in tokamak plasmas

    International Nuclear Information System (INIS)

    Strauss, H.R.; Park, W.; Belova, E.; Fu, G.Y.; Sugiyama, L.E.

    1999-01-01

    Nonlinear MHD simulation results of pellet injection show that MHD forces can accelerate large pellets, injected on the high field side of a tokamak, to the plasma center. Magnetic reconnection can produce a reverse shear q profile. Ballooning instability caused by pellets is also reduced by high field side injection. Studies are also reported of the current quench phase of disruptions, which can cause 3D halo currents and runaway electrons. (author)

  9. A Two-Sided Market Model of Optimal Price Structure for Instant Messenger

    Directory of Open Access Journals (Sweden)

    Jun Xu

    2013-01-01

    Full Text Available Instant messenger (IM is one of the most popular Internet applications all over the world. This paper examines the pricing problem of IM based on two-sided market model. IM serves as a two-sided platform, which gets both Internet users and advertisers on board. This paper concludes that IM operator adopts a heavily skewed price structure that favors IM users both under monopolistic case and under horizontal differentiated duopolistic case. When advertising revenue is large enough relatively to marginal cost for serving IM users, IM users can enjoy free service provided by IM operators. The competitive equilibrium of duopolistic case is not necessarily symmetric when advertisers choose singlehoming. Even in the symmetric equilibrium platform would rather deter all advertisers.

  10. Using cold air for reducing needle-injection pain.

    Science.gov (United States)

    Al-Qarqaz, Firas; Al-Aboosi, Mustafa; Al-shiyab, Diala; Al Dabbagh, Ziad

    2012-07-01

    Pain is associated with skin injections. Reducing injection-associated pain is important especially when multiple injections are needed in difficult areas, such as the palms. We present a new safe application for cold air used in laser therapy. The main objectives of this study are to see whether cold air can reduce needle-injection pain and to evaluate the safety of this new application. Patients undergoing skin injection (n=40) were included. Assessment of pain level using visual analog scale (VAS) was done using cold air and again without cold air in the same patient. Comparison of pain scores was performed. Thirty-three patients had lower VAS scores using cold air. Five patients had worse VAS scores, and two patients did not have any change in their pain score. In the group of patients where injections were made to the palms (n=5), there was even more reduction in VAS scores. There were no significant immediate or delayed side effects. Cold air seems to be useful in reducing needle-injection pain in the majority of patients, especially in the palms. This procedure is safe, apart from immediate tolerable discomfort when used around the nose. © 2012 The International Society of Dermatology.

  11. The choice between two designs for the safety-injection system of a pressurized-water reactor, using probabilistic methods

    International Nuclear Information System (INIS)

    Villemeur, Alain

    1982-01-01

    A probabilistic study has been carried out to compare two designs for the safety-injection circuit of a pressurized-water reactor. It appears that unavailability of the circuit after an accident involving loss of coolant decreases little when one moves from a 2-line to a 3-line system. These results are compared with the disadvantages arising from increased redundancy, and in particular the increased cost of the installations. The 2-line circuit appears the optimum one on the basis of cost and reliability criteria. It has been chosen for the 1300-MWe units [fr

  12. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  13. Method for operating a spark-ignition, direct-injection internal combustion engine

    Science.gov (United States)

    Narayanaswamy, Kushal; Koch, Calvin K.; Najt, Paul M.; Szekely, Jr., Gerald A.; Toner, Joel G.

    2015-06-02

    A spark-ignition, direct-injection internal combustion engine is coupled to an exhaust aftertreatment system including a three-way catalytic converter upstream of an NH3-SCR catalyst. A method for operating the engine includes operating the engine in a fuel cutoff mode and coincidentally executing a second fuel injection control scheme upon detecting an engine load that permits operation in the fuel cutoff mode.

  14. One-month injectables are popular choice in Mexico.

    Science.gov (United States)

    1984-01-01

    In Latin America over 100,000 women use monthly injectable contraceptives. These injectables are not part of any national program and are manufactured by local companies. Convenience and secretiveness were 2 primary reasons given by a group of injectable contraceptive users for preferring this method to all other forms of birth control. This was 1 of the findings of a study undertaken by Promotora de Planificacion Familiar A.C. (PROFAM) in Mexico to assess the market for a 1 month injectable, to include in its contraceptive social marketing program. In depth information was obtained about the attitudes and perceptions of present users of injectables with regard to the advantages of the method compared to other contraceptives and the motivation to use the 1 month rather than the 3 month product. In December 1983 PROFAM conducted a motivational study of injectable contraceptive users, utilizing 4 discussion groups composed of women who used 1 month injectables and were residents of several randomly selected lower middle income and low income areas of metropolitan Mexico City. The older women in the study had generally begun to use injectables after other methods were deemed unsatisfactory. They had either had physical or psychological complaints about their previous methods or were worried about effectiveness. Injectables were considered by all the women to be "less troublesome" than but as effective as either oral contraceptives (OCs) or the IUD. Features most often cited in favor of injectables were their effectiveness, lack of rumors about side effects, the possibility of secrecy, and ease of correct use. Knowledge about injectables was widespread, and the women reported no difficulty in getting the information they wanted from friends, drugstore personnel, or doctors. The product usually reached the consumer without a medical prescription. Finding someone to administer the shot was the principal drawback of an injectable contraceptive. Middle class women usually

  15. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  16. injection-induced sciatic nerve injury among children managed in an

    African Journals Online (AJOL)

    user

    their carers and relatives, had the injections administered by nurses. The results ... and health professionals who administer injections adhere strictly to safe ethical practices and that unqualified personnel are ... presently a common practice in developing countries, ... age, side affected, personnel/place where injection was.

  17. Measured emittance dependence on injection method in laser plasma accelerators

    Science.gov (United States)

    Barber, Samuel; van Tilborg, Jeroen; Schroeder, Carl; Lehe, Remi; Tsai, Hai-En; Swanson, Kelly; Steinke, Sven; Nakamura, Kei; Geddes, Cameron; Benedetti, Carlo; Esarey, Eric; Leemans, Wim

    2017-10-01

    The success of many laser plasma accelerator (LPA) based applications relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot transverse emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock induced density down-ramp injection. Notably, the measurements reveal that ionization injection results in significantly higher emittance. With the down-ramp injection configuration, emittances less than 1 micron at spectral charge densities up to 2 pC/MeV were measured. This work was supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the NSF under Grant No. PHY-1415596, by the U.S. DOE NNSA, DNN R&D (NA22), and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  18. Optical trapping and binding of particles in an optofluidic stable Fabry-Pérot resonator with single-sided injection.

    Science.gov (United States)

    Gaber, Noha; Malak, Maurine; Marty, Frédéric; Angelescu, Dan E; Richalot, Elodie; Bourouina, Tarik

    2014-07-07

    In this article, microparticles are manipulated inside an optofluidic Fabry-Pérot cylindrical cavity embedding a fluidic capillary tube, taking advantage of field enhancement and multiple reflections within the optically-resonant cavity. This enables trapping of suspended particles with single-side injection of light and with low optical power. A Hermite-Gaussian standing wave is developed inside the cavity, forming trapping spots at the locations of the electromagnetic field maxima with a strong intensity gradient. The particles get arranged in a pattern related to the mechanism affecting them: either optical trapping or optical binding. This is proven to eventually translate into either an axial one dimensional (1D) particle array or a cluster of particles. Numerical simulations are performed to model the field distributions inside the cavity allowing a behavioral understanding of the phenomena involved in each case.

  19. Skeletal 212Pb retention following 224Ra injection: extrapolation of animal data to adult humans

    International Nuclear Information System (INIS)

    Schlenker, R.A.

    1988-01-01

    Two methods of interspecies extrapolation, one based on a correlation of skeletal 212 Pb/ 224 Ra with body weight, the other based on the mechanistic relationship between skeletal 212 Pb/ 224 Ra and reciprocal bone surface-to-volume ratio, lead to the conclusion that the retention of 212 Pb in the adult human skeleton is approximately complete a few days after injection. The correlation-based method gives most probable values for 212 Pb/ 224 Ra of 1.0 and 1.1 at 2 d and 7 d after injection, compared with values of 1.05 and 1.27 expected at these same times if the retention of 212 Pb were complete from the time of injection and if no 212 Pb were in the injection solution. The range of values corresponding to one geometric standard error on either side of the most probable value is 0.87 to 1.21 at 2 d post-injection. With the method based on the reciprocal bone surface-to-volume ratio, the best estimate of 212 Pb/ 224 Ra at 2 d after injection is 0.88, equal to the value observed in young adult beagles. An alternative interpretation of the results of this latter method leads to the conclusion that retention is complete, with 212 Pb/ 224 Ra equal to 1.0 for a 212 Pb-free injection solution and 1.1 for a solution containing 212 Pb in secular equilibrium with 224 Ra. This work, which uses 224 Ra daughter product retention data from mice, rats and dogs following 224Ra injection, provides a scientific foundation for retention assumptions made in the calculation of mean skeletal dose for adult humans. There now appear to be few uncertainties in these latter dose values, stemming from inaccurate retention assumptions; but substantial uncertainties remain in the mean skeletal dose values for juveniles and in the endosteal tissue doses regardless of age

  20. Apparatus and method for continuous production of materials

    Science.gov (United States)

    Chang, Chih-hung; Jin, Hyungdae

    2014-08-12

    Embodiments of a continuous-flow injection reactor and a method for continuous material synthesis are disclosed. The reactor includes a mixing zone unit and a residence time unit removably coupled to the mixing zone unit. The mixing zone unit includes at least one top inlet, a side inlet, and a bottom outlet. An injection tube, or plurality of injection tubes, is inserted through the top inlet and extends past the side inlet while terminating above the bottom outlet. A first reactant solution flows in through the side inlet, and a second reactant solution flows in through the injection tube(s). With reference to nanoparticle synthesis, the reactant solutions combine in a mixing zone and form nucleated nanoparticles. The nucleated nanoparticles flow through the residence time unit. The residence time unit may be a single conduit, or it may include an outer housing and a plurality of inner tubes within the outer housing.

  1. Qualification Methods of Al2O3 Injection Molding Raw Materials

    International Nuclear Information System (INIS)

    Egész, Á; Gömze, L A

    2015-01-01

    For producing ceramic arc tube parts (plugs), there are used two different major components for producing injection molding raw material (feedstock): high purity alumina powder as the main component, and an organic paraffin wax as a binder material. It is expressly important to know the material, physical and chemical properties of these components, since mainly these have effect on the homogenity of feedstock, and therefore on the quality of end product. In this research, both of the main components and the moldable raw material was investigated by visual, physical, and thermal methods. As most important and main statement, the researchers found that the dynamic viscosity of raw material depends more on the applied temperature, than on the deformation speed gradient.Applied analitycal methods were laser granulometry, sieve analysis, differential thermal analysis and rheology analysis. (paper)

  2. A Reliable Method for the Evaluation of the Anaphylactoid Reaction Caused by Injectable Drugs

    Directory of Open Access Journals (Sweden)

    Fang Wang

    2016-10-01

    Full Text Available Adverse reactions of injectable drugs usually occur at first administration and are closely associated with the dosage and speed of injection. This phenomenon is correlated with the anaphylactoid reaction. However, up to now, study methods based on antigen detection have still not gained wide acceptance and single physiological indicators cannot be utilized to differentiate anaphylactoid reactions from allergic reactions and inflammatory reactions. In this study, a reliable method for the evaluation of anaphylactoid reactions caused by injectable drugs was established by using multiple physiological indicators. We used compound 48/80, ovalbumin and endotoxin as the sensitization agents to induce anaphylactoid, allergic and inflammatory reactions. Different experimental animals (guinea pig and nude rat and different modes of administration (intramuscular, intravenous and intraperitoneal injection and different times (15 min, 30 min and 60 min were evaluated to optimize the study protocol. The results showed that the optimal way to achieve sensitization involved treating guinea pigs with the different agents by intravenous injection for 30 min. Further, seven related humoral factors including 5-HT, SC5b-9, Bb, C4d, IL-6, C3a and histamine were detected by HPLC analysis and ELISA assay to determine their expression level. The results showed that five of them, including 5-HT, SC5b-9, Bb, C4d and IL-6, displayed significant differences between anaphylactoid, allergic and inflammatory reactions, which indicated that their combination could be used to distinguish these three reactions. Then different injectable drugs were used to verify this method and the results showed that the chosen indicators exhibited good correlation with the anaphylactoid reaction which indicated that the established method was both practical and reliable. Our research provides a feasible method for the diagnosis of the serious adverse reactions caused by injectable drugs which

  3. Target injection methods for inertial fusion energy

    International Nuclear Information System (INIS)

    Petzoldt, R.W.; Moir, R.W.

    1994-06-01

    We have studied four methods to inject IFE targets: the gas gun, electrostatic accelerator, induction accelerator, and rail gun. We recommend a gas gun for indirect drive targets because they can support a gas pressure load on one end and can slide along the gun barrel without damage. With the gas gun, the amount of gas required for each target (about 10 to 100 mg) is acceptable; for other types of targets, a sabot would be necessary. A cam and poppet valve arrangement is recommended for gas flow control. An electrostatic accelerator is attractive for use with lightweight spherical direct drive targets. Since there is no physical contact between the target and the injector, there will be no wear of either component during the injection process. An induction accelerator has an advantage of no electrical contact between the target and the injector. Physical contact is not even necessary, so the wear should be minimal. It requires a cylindrical conductive target sleeve which is a substantial added mass. A rail gun is a simpler device than an electrostatic accelerator or induction accelerator. It requires electrical contact between the target and the rails and may have a significant wear rate. The wear in a vacuum could be reduced by use of a solid lubricant such as MoS 2 . The total required accuracy of target injection, tracking and beam pointing of ±0.4 mm appears achievable but will require development and experimental verification

  4. A Comparison of Fueling with Deuterium Pellet Injection from Different Locations on the DIII-D Tokamak

    International Nuclear Information System (INIS)

    Baylor, L.R.; Combs, S.K.; Gohil, P.; Houlberg, W.A.; Hsieh, C.; Jernigan, T.C.; Parks, P.B.

    1999-01-01

    Initial pellet injection experiments on DIII-D with high field side (HFS) injection have demonstrated that deeper pellet fuel deposition is possible even with HFS injected pellets that are significantly slower than pellets injected from the low field side (LFS) (outer midplane) location. A radial displacement of the pellet mass shortly after or during the ablation process is consistent with the observed mass deposition profiles measured shortly after injection. Vertical injection inside the magnetic axis shows some improvement in fueling efficiency over LFS injection and may provide an optimal injection location for fueling with high speed pellets

  5. Injection therapy for chronic prostatitis: A retrospective analysis of 77 cases

    Directory of Open Access Journals (Sweden)

    Attila Toth

    2018-03-01

    Full Text Available Objective: To compare pre- and post-therapy symptom scores reported on the National Institute of Health Chronic Prostatitis Symptom Index (NIHCPSI after trans-rectal antibiotic injections therapy for men suffering from chronic prostatitis. Materials and methods: Retrospective analysis of NIHCPSI symptom scores obtained from chart reviews of 77 treated males suffering from chronic prostatitis before and after trans rectal injections for the treatment of chronic prostatitis. Results: Most patients reported a 40% to 60% improvement in symptom scores. In subgroups comparing scores in patients with less than 5 injections, the improvement was less than in patients who received 10 or more injections. Patients’ responses after a shorter (3 months follow up showed better pain scores than patient’s scores after longer, over one-year or more, follow- up periods. Conclusion: Our findings show that direct antibiotic injection for chronic prostatitis is a viable addition to standard therapies. Improvements in symptom scores are long lasting. Discomfort is minimal and side effects are rare and avoidable

  6. Social long-term care insurance with two-sided altruism

    OpenAIRE

    Cremer, Helmuth; Pestieau, Pierre; Roeder, Kerstin

    2015-01-01

    This paper studies the design of a social long-term care (LTC) insurance when altruism is two-sided. The laissez-faire solution is not efficient, unless there is perfect altruism. Under full information, the first-best can be decentralized by a linear subsidy on informal aid, a linear tax on bequests when the parent is dependent and state specific lump-sum transfers which provide insurance. We also study a second-best scheme comprising a LTC benefit, a payroll tax on children's earnings and a...

  7. Whole Genome Analysis of Injectional Anthrax Identifies Two Disease Clusters Spanning More Than 13 Years

    Directory of Open Access Journals (Sweden)

    Paul Keim

    2015-11-01

    Lay Person Interpretation: Injectional anthrax has been plaguing heroin drug users across Europe for more than 10 years. In order to better understand this outbreak, we assessed genomic relationships of all available injectional anthrax strains from four countries spanning a >12 year period. Very few differences were identified using genome-based analysis, but these differentiated the isolates into two distinct clusters. This strongly supports a hypothesis of at least two separate anthrax spore contamination events perhaps during the drug production processes. Identification of two events would not have been possible from standard epidemiological analysis. These comprehensive data will be invaluable for classifying future injectional anthrax isolates and for future geographic attribution.

  8. Simultaneous Treatment with Subcutaneous Injection of Golimumab and Intra-articular Injection of Triamcinolone Acetonide (K-Method in Patients with Rheumatoid Arthritis Undergoing Switching of Biologics: Retrospective Case–Control Study

    Directory of Open Access Journals (Sweden)

    Katsuaki Kanbe

    2016-01-01

    Full Text Available Background Tight control of severe rheumatoid arthritis (RA in patients with high disease activity, even when using biologics, is sometimes difficult using a treat-to-target strategy. Switching from one biologic to another is associated with lower efficacy than that in treatment-naive cases. We developed the K-method that involves simultaneous treatment with golimumab and intra-articular joint injection of triamcinolone acetonide (TA in patients undergoing switching of biologics. We performed this retrospective case–control study to investigate the efficacy of achieving an immediate treatment response using the K-method. Methods This study involved 20 patients with RA (control group, 10 patients; K-method group, 10 patients. Patients in the control group were switched to golimumab from other biologics without intra-articular injection of TA. The K-method involved injection of 1 mL of TA (40 mg/mL and 2 mL of 1% lidocaine hydrochloride into swollen or painful joints on the same day as golimumab treatment. A quick response one day after treatment was compared between the two groups according to the disease activity score 28 based on C-reactive protein (DAS28 CRP, clinical disease activity index (CDAI, simplified disease activity index (SDAI, European League Against Rheumatism (EULAR response, and remission rate. These parameters were investigated for 24 weeks. Results The K-method group showed significant improvements in DAS28 CRP, CDAI, and SDAI at one day, 12 weeks, and 24 weeks compared with the control group. The number of swollen and tender joints and the patient and doctor global visual analog scale scores were also significantly different between the two groups. The remission rates based on DAS28 CRP were 30% at one day, 50% at 12 weeks, and 60% at 24 weeks in the K-method group. The EULAR good/moderate response rates were 80% at one day, 90% at 12 weeks, and 90% at 24 weeks in the K-method group; however, these rates were only 10%, 40

  9. Computer program determines exact two-sided tolerance limits for normal distributions

    Science.gov (United States)

    Friedman, H. A.; Webb, S. R.

    1968-01-01

    Computer program determines by numerical integration the exact statistical two-sided tolerance limits, when the proportion between the limits is at least a specified number. The program is limited to situations in which the underlying probability distribution for the population sampled is the normal distribution with unknown mean and variance.

  10. Safe Injection Practices in Primary Health Care Settings of Naxalbari Block, Darjeeling District, West Bengal.

    Science.gov (United States)

    Chaudhuri, Sudip Banik; Ray, Kuntala

    2016-01-01

    Unsafe injection can transmit many diseases to patients, injection providers and healthy people of community. To find out critical steps whether executed according to recommended best practice methods, availability of equipments in health facilities for safe injection practices and some important steps of waste disposal methods. This facility-based cross-sectional observational study was conducted among 30 Auxiliary nurse midwives (ANM) & 27 nursing staffs (NS) to assess certain aspects of their practice while administrating injection and disposal of the disposables. Health facilities were also observed to asses necessary equipments of safe injection and waste disposal methods. Among the health workers 93.3% ANM and 100% NS took sterile syringe from sterile unopened packet, all of the study subjects washed hand before giving injection, 13.3% of ANMs and 8% of NS are fully vaccinated against Hep B, 53.3% of ANM and all NS are practices non recapping. Only 13.33% sub centres along with PHC & BPHC had at least one puncture resistant leak proof container, 86.7% sub centres, PHC are free from loose needles. Transport for off side treatment is the method of waste disposal in case of 73.3% cases sub centres, PHC & BPHC. There is need to educate, train and motivate service providers in proper methods of giving injection along with improve the adequacy of supply of required equipments.

  11. Using biplanar fluoroscopy to guide radiopaque vascular injections: a new method for vascular imaging.

    Directory of Open Access Journals (Sweden)

    Haley D O'Brien

    Full Text Available Studying vascular anatomy, especially in the context of relationships with hard tissues, is of great interest to biologists. Vascular studies have provided significant insight into physiology, function, phylogenetic relationships, and evolutionary patterns. Injection of resin or latex into the vascular system has been a standard technique for decades. There has been a recent surge in popularity of more modern methods, especially radiopaque latex vascular injection followed by CT scanning and digital "dissection." This technique best displays both blood vessels and bone, and allows injections to be performed on cadaveric specimens. Vascular injection is risky, however, because it is not a standardizable technique, as each specimen is variable with regard to injection pressure and timing. Moreover, it is not possible to view the perfusion of injection medium throughout the vascular system of interest. Both data and rare specimens can therefore be lost due to poor or excessive perfusion. Here, we use biplanar video fluoroscopy as a technique to guide craniovascular radiopaque latex injection. Cadaveric domestic pigs (Sus scrofa domestica and white-tailed deer (Odocoileus virginianus were injected with radiopaque latex under guidance of fluoroscopy. This method was found to enable adjustments, in real-time, to the rate, location, and pressure at which latex is injected in order to avoid data and specimen loss. In addition to visualizing the injection process, this technique can be used to determine flow patterns, and has facilitated the development of consistent markers for complete perfusion.

  12. Fault injection as a test method for an FPGA in charge of data readout for a large tracking detector

    CERN Document Server

    Roed, K; Richter, M; Fehlker, D; Helstrup, H; Alme, J; Ullaland, K

    2011-01-01

    This paper describes how fault injection has been implemented as a test method for an FPGA in an existing hardware configuration setup. As this FPGA is in charge of data readout for a large tracking detector, the reliability of this FPGA is of high importance. Due to the complexity of the readout electronics, irradiation testing is technically difficult at this stage of the system commissioning. The work presented in this paper is therefore motivated by introducing fault injection as an alternative method to characterize failures caused by SEUs. It is a method to study the effect that a configuration upset may have on the operation of the FPGA. The target platform consists of two independent modules for data acquisition and detector control functionality. Fault injection to test the response of the data acquisition module is made possible by implementing the solution as part of the detector control functionality. Correct implementation is validated by a simple shift register design. Our results demonstrate th...

  13. Injection locking method for Raman beams in atom interferometer

    Science.gov (United States)

    Zi, Fei; Deng, Jianing; Zeng, Daji; Li, Tong; Sun, Mingli; Zhang, Xian; Huang, Kaikai; Lu, Xuanhui

    2018-03-01

    We present a novel method to generate two phase-locked beams with a frequency offset of 6.834 GHz. The output of the master laser is firstly modulated by an electric optical modulator (EOM), and then further injected into an Extended Cavity Diode Lasers (ECDL) which is used to filter out the unwanted mode and amplify the laser power. By locking to the first-order lower sideband of the modulated master laser, the average variance of the phase fluctuations is 5.6 x 10-3 rad2 , which implies phase coherence of 99.44% between the master laser and the slave ECDL. The line width of the beat notes is less than 1Hz. For the long term stability, with the delicate design of the electronic controller in ECDL, the phase coherence of the two laser beams can be stabilized over 200 hours without any adjustment. The Raman system is applicable for gravity detection with a preliminary sensitivity Δg/g of 4.5 x 10-7 for interrogation time of 1500 s.

  14. Liposomal Bupivacaine Injection Technique in Total Knee Arthroplasty.

    Science.gov (United States)

    Meneghini, R Michael; Bagsby, Deren; Ireland, Philip H; Ziemba-Davis, Mary; Lovro, Luke R

    2017-01-01

    Liposomal bupivacaine has gained popularity for pain control after total knee arthroplasty (TKA), yet its true efficacy remains unproven. We compared the efficacy of two different periarticular injection (PAI) techniques for liposomal bupivacaine with a conventional PAI control group. This retrospective cohort study compared consecutive patients undergoing TKA with a manufacturer-recommended, optimized injection technique for liposomal bupivacaine, a traditional injection technique for liposomal bupivacaine, and a conventional PAI of ropivacaine, morphine, and epinephrine. The optimized technique utilized a smaller gauge needle and more injection sites. Self-reported pain scores, rescue opioids, and side effects were compared. There were 41 patients in the liposomal bupivacaine optimized injection group, 60 in the liposomal bupivacaine traditional injection group, and 184 in the conventional PAI control group. PAI liposomal bupivacaine delivered via manufacturer-recommended technique offered no benefit over PAI ropivacaine, morphine, and epinephrine. Mean pain scores and the proportions reporting no or mild pain, time to first opioid, and amount of opioids consumed were not better with PAI liposomal bupivacaine compared with PAI ropivacaine, morphine, and epinephrine. The use of the manufacturer-recommended technique for PAI of liposomal bupivacaine does not offer benefit over a conventional, less expensive PAI during TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Side effects and complications of intraosseous anesthesia and conventional oral anesthesia.

    Science.gov (United States)

    Peñarrocha-Oltra, David; Ata-Ali, Javier; Oltra-Moscardó, María-José; Peñarrocha-Diago, María; Peñarrocha, Miguel

    2012-05-01

    To analyze the side effects and complications following intraosseous anesthesia (IA), comparing them with those of the conventional oral anesthesia techniques. A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for respective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. Heart rate was recorded in all cases before injection of the anesthetic solution and again 30 seconds after injection. The complications observed after anesthetic administration were recorded. A total of 200 oral anesthetic procedures were carried out in 100 patients. Both IA and conventional anesthesia resulted in a significant increase in heart rate, though the increase was greater with the latter technique. Incidents were infrequent with either anesthetic technique, with no significant differences between them. Regarding the complications, there were significant differences in pain at the injection site, with more intense pain in the case of IA (x2=3.532, p=0.030, Φ2=0.02), while the limitation of oral aperture was more pronounced with conventional anesthesia (x2=5.128, panesthesia. Post-anesthetic biting showed no significant differences between the two techniques.

  16. Hydrogen/oxygen injection stopping method for nuclear power plant and emergent hydrogen/oxygen injection device

    International Nuclear Information System (INIS)

    Ishida, Ryoichi; Ota, Masamoto; Takagi, Jun-ichi; Hirose, Yuki

    1998-01-01

    The present invention provides a device for suppressing increase of electroconductivity of reactor water during operation of a BWR type reactor, upon occurrence of reactor scram of the plant or upon stopping of hydrogen/oxygen injection due to emergent stoppage of an injection device so as not to deteriorate the integrity of a gas waste processing system upon occurrence of scram. Namely, when injection of hydrogen/oxygen is stopped during plant operation, the injection amount of hydrogen is reduced gradually. Subsequently, injection of hydrogen is stopped. With such procedures, the increase of electroconductivity of reactor water can be suppressed upon stoppage of hydrogen injection. When injection of hydrogen/oxygen is stopped upon shut down of the plant, the amount of hydrogen injection is changed depending on the change of the feedwater flow rate, and then the plant is shut down while keeping hydrogen concentration of feedwater to a predetermined value. With such procedures, increase of the reactor water electroconductivity can be suppressed upon stoppage of hydrogen injection. Upon emergent stoppage of the hydrogen/oxygen injection device, an emergent hydrogen/oxygen injection device is actuated to continue the injection of hydrogen/oxygen. With such procedures, elevation of reactor water electroconductivity can be suppressed. (I.S.)

  17. Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties.

    Science.gov (United States)

    Šatínský, Dalibor; Chocholouš, Petr; Válová, Olga; Hanusová, Lucia; Solich, Petr

    2013-09-30

    This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Diversion and injection of buprenorphine-naloxone film two years post-introduction in Australia.

    Science.gov (United States)

    Larance, Briony; Mattick, Richard; Ali, Robert; Lintzeris, Nicholas; Jenkinson, Rebecca; White, Nancy; Kihas, Ivana; Cassidy, Rosemary; Degenhardt, Louisa

    2016-01-01

    We report 2 years of post-marketing surveillance of the diversion and injection of buprenorphine-naloxone (BNX) film following its introduction in 2011. Interviews were conducted with people who inject drugs regularly (PWID) (2004-2013), opioid substitution therapy clients (2013, n = 492) and key experts (n = 44). Key outcomes were unsanctioned removal of supervised doses, diversion, injection and street price. Prevalence of past 6-month injection among PWID was adjusted for background availability of opioid substitution therapy medications using sales data. Among out-of-treatment PWID, the levels of regular (weekly+) BNX film injection were comparable to methadone and BNX tablets, and lower than mono-buprenorphine, adjusting for background availability. Fewer BNX film clients [3%; 95% (CI) 1-5] regularly injected their medication than mono-buprenorphine clients (25%; 95% CI 11-39), but at levels equivalent to those among methadone (3%; 95% CI 1-6) and BNX tablet clients (2%; 95% CI 0-6). Key experts perceived BNX film needed less supervised dosing time as it dissolved rapidly and was harder to remove from the mouth than sublingual tablets; however, removal of supervised doses was higher among BNX film clients (15%; 95% CI: 10-20) than methadone clients (3%; 95% CI 1-6), and not significantly different from BNX tablet (11%; 95% CI 2-21) and mono-buprenorphine clients (31%; 95% CI 16-46). Two years post-introduction, levels of BNX film diversion and injection remained comparable with those for methadone and BNX tablets, and lower than mono-buprenorphine. We found no evidence that BNX film has lower non-adherence and diversion than the tablet formulation. [Larance B, Mattick R, Ali R, Lintzeris N, Jenkinson R, White N, Kihas I, Cassidy R, Degenhardt L. Diversion and injection of buprenorphine-naloxone film two years post-introduction in Australia. Drug Alcohol Rev 2015]. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  19. Treatment of the Infection after Fat Injection

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2015-01-01

    Full Text Available For recent years, use of autologous fat injection has increased significantly in facial contouring surgery. Along with such increase in use, complications like atypical mycoplasma infection have been also on the increasing trend. The authors report two cases of Mycobacterium chelonae infection that occurred after autologous fat injection. Patients were treated as infection that resistant to common antibiotics and results were negative to routine culture and Gram staining. Acid-fast bacillus stain, polymerase chain reaction (PCR test and mycobacterial cultures were conducted for diagnosis under suspicion of atypical mycoplasma infection. Then, combination antibiotics therapy, surgical treatment, and steroid injection were performed for treatment. Both patients were diagnosed with Mycobacterium chelonae in PCR test. They were positive to mycobacterial cultures. Combination antibiotics therapy was repeated to improvement of symptom. However, they could not be free from side effects such as deformation in facial contour, scar and pigmentation even after full recovery. When chronic wound infections after autologous fat injection, we must suspect atypical or mycobacterial infection and conduct examinations for a early diagnosis and proper antibiotic therapy that is effective to the nontuberculous mycobacteria.

  20. Peace and development: two sides of the same coin?

    Directory of Open Access Journals (Sweden)

    Viveros Tafur, Memphis Ronald

    2015-07-01

    Full Text Available There is the notion that peace and development are positively correlated, that peace drives development and that development drives peace, for Galtung (1985: 147 Peace and Development should be regarded as two sides of the same coin and considers development in relation to peace. This paper shows that peace and development are uncorrelated in several countries where there is peace without development or development without peace. The use of quantitative models as a tool for the analysis is a plus for the findings because most of the related theories are qualitative.

  1. Comparison of the therapeutic effect between a transforminal along with a caudal epidural injection, as well as two-level transforaminal epidural injections ina radiculopathy patient

    International Nuclear Information System (INIS)

    Hwang, Jung Han; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keun Won; Kim, Young Joong; Seo, Jae Young; Lim, Seong Joo; Kang, Byeong Seong

    2017-01-01

    The aim of this study was to evaluate the therapeutic effect of a transforaminal epidural steroid injection (TFESI) along with a caudal epidural steroid injection (ESI), compared to two-level TFESIs in a multi-level radiculopathy patient. A total of 895 lumbar ESIs were performed in 492 patients with multi-level radiculopathy from January 2012 to January 2015. Before injections were performed, the initial Numeric Rating Scale (NRS) score was assessed in all patients, categorized into no pain (excellent), mild (good, NRS: 1-3), moderate (fair, NRS: 4-6), and severe pain (poor, NRS: 7-10). Therapeutic effects were examined for two groups: one-level TFESI along with caudal and ESI two-level TFESIs. Patient outcomes were assessed by NRS in a serial follow-up at one, three, and six months. One TFESI along with caudal ESI was performed in 274 patients and two TFESIs for 218. For the former group with one TFESI along with caudal ESI, excellent results were shown: 219 (79.9%) patients after one month, 200 (72.9%) after three, and 193 (70.4%) after six months. In the patient group with two TFESIs (n = 218) the outcomes were also very good: 152 (69.7%) after one month, 131 (60.0%) after three months, and 123 (56.4%) patients after six months. The therapeutic effect of one TFESI along with caudal ESI was better than two TFESIs in for one, threes, and six months (p < 0.01). Transforaminal epidural steroid with caudal epidural injection is a more effective tool for lumbosacral radiculopathy than two level transforaminal injections in multi-level radiculopathy patients

  2. Comparison of the therapeutic effect between a transforminal along with a caudal epidural injection, as well as two-level transforaminal epidural injections ina radiculopathy patient

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jung Han; Hwang, Cheol Mog; Cho, Young Jun; Kim, Keun Won; Kim, Young Joong; Seo, Jae Young; Lim, Seong Joo [Dept. of Diagnostic Radiology, Konyang University Hospital, Deajeon (Korea, Republic of); Kang, Byeong Seong [Dept. of Radiology, University of Ulsan College of Medicine, Ulsan University Hospital, Ulsan (Korea, Republic of)

    2017-01-15

    The aim of this study was to evaluate the therapeutic effect of a transforaminal epidural steroid injection (TFESI) along with a caudal epidural steroid injection (ESI), compared to two-level TFESIs in a multi-level radiculopathy patient. A total of 895 lumbar ESIs were performed in 492 patients with multi-level radiculopathy from January 2012 to January 2015. Before injections were performed, the initial Numeric Rating Scale (NRS) score was assessed in all patients, categorized into no pain (excellent), mild (good, NRS: 1-3), moderate (fair, NRS: 4-6), and severe pain (poor, NRS: 7-10). Therapeutic effects were examined for two groups: one-level TFESI along with caudal and ESI two-level TFESIs. Patient outcomes were assessed by NRS in a serial follow-up at one, three, and six months. One TFESI along with caudal ESI was performed in 274 patients and two TFESIs for 218. For the former group with one TFESI along with caudal ESI, excellent results were shown: 219 (79.9%) patients after one month, 200 (72.9%) after three, and 193 (70.4%) after six months. In the patient group with two TFESIs (n = 218) the outcomes were also very good: 152 (69.7%) after one month, 131 (60.0%) after three months, and 123 (56.4%) patients after six months. The therapeutic effect of one TFESI along with caudal ESI was better than two TFESIs in for one, threes, and six months (p < 0.01). Transforaminal epidural steroid with caudal epidural injection is a more effective tool for lumbosacral radiculopathy than two level transforaminal injections in multi-level radiculopathy patients.

  3. Fluoroscopy-Guided Sacroiliac Intraarticular Injection via the Middle Portion of the Joint.

    Science.gov (United States)

    Kurosawa, Daisuke; Murakami, Eiichi; Aizawa, Toshimi

    2017-09-01

    Sacroiliac intraarticular injection is necessary to confirm sacroiliac joint (SIJ) pain and is usually performed via the caudal one-third portion of the joint. However, this is occasionally impossible for anatomical reasons, and the success rate is low in clinical settings. We describe a technique via the middle portion of the joint. Observational study. Enrolled were 69 consecutive patients (27 men and 42 women, with an average age of 53 years) in whom the middle portion of 100 joints was targeted. With the patient lying prone-oblique with the painful side down, a spinal needle was inserted into the middle portion of the joint. Subsequently, the fluoroscopy tube was angled at a caudal tilt of 25-30° to clearly detect the recess between the ilium and sacrum and the needle depth and direction. When the needle reached the posterior joint line, 2% lidocaine was injected after the contrast medium outlined the joint. The success rate of the injection method was 80% (80/100). Among 80 successful cases, four were previously unsuccessful when the conventional method was used. Intraarticular injection using the new technique was unsuccessful in 20 joints; in three of these cases, the conventional method proved successful, and no techniques were successful in the other 17 cases. The injection technique via the middle portion of the joint can overcome some of the difficulties of the conventional injection method and can improve the chances of successful intraarticular injection. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  4. Comparison of the efficacy of two combined therapies for peptic ulcer bleeding: adrenaline injection plus haemoclipping versus adrenaline injection followed by bipolar electrocoagulation

    Science.gov (United States)

    Świdnicka-Siergiejko, Agnieszka; Wróblewski, Eugeniusz; Baniukiewicz, Andrzej; Dąbrowski, Andrzej

    2014-01-01

    Introduction Peptic ulcer remains the most frequent cause of upper gastrointestinal bleeding. Treatment of bleeding with simultaneous combination of two endoscopic techniques has proved to be more efficient than monotherapy. None of the published comparative studies of various contact coagulation modalities have confirmed the superiority of one of these techniques over the others. Aim To compare the therapeutic outcomes of the use of a device enabling both injection of adrenaline solution and bipolar electrocoagulation (A + BE) to those of combined adrenaline injection with mechanical therapy (haemostatic clips) (A + HC) in the treatment of peptic ulcer bleeding. Material and methods Fifty-two subjects with bleeding ulcers were assigned to the A + BE group, and 55 patients were treated with A + HC. Results Overall, treatment failed in 20 patients (20/107, 18.7%): in 10 individuals from the A + BE group (10/52; 18.2%) and in 10 individuals from the A + HC group (10/55; 19.2%) (p > 0.05). Primary haemostasis was not obtained in 7 patients (6.5%): in 4 patients in the A + BE group and in 3 patients in the A + HC group (p > 0.05). Ten individuals (9.3%) experienced recurrent bleeding during hospitalisation: 4 patients from the A + BE group and 6 patients from the A + HC group (p > 0.05). Finally, in 96.3% of the patients (n = 103) the endoscopic treatment proved efficient with regards to obtaining haemostasis during hospitalisation. Surgical intervention was required in 4 individuals (3.7%): 2 patients in the A + BE group and 2 patients treated with A + HC (p > 0.05). Three patients (2.8%) – all from the A + HC group – died during hospitalisation. No significant intergroup differences were documented with regards to the mean number of transfused blood units and the mean length of hospital stay. Conclusions The efficacy of combined endoscopic treatment of ulcer bleeding with a probe enabling simultaneous bipolar electrocoagulation and adrenaline injection seems

  5. Performance analysis of a small regenerative gas turbine system adopting steam injection and side-wall in finned tube evaporator

    International Nuclear Information System (INIS)

    Kang, Soo Young; Lee, Jong Jun; Kim, Tong Seop

    2009-01-01

    Small gas turbines in power range of several MWs are quite suitable for application in distributed generation as well as Community Energy Systems (CES). Humidification is an effective way to improve gas turbine performance, and steam injection is the most general and practically feasible method. This study intended to examine the effect of steam injection on the performance of several MW class gas turbines. A primary concern is given to the regenerative cycle gas turbine. The steam injection effect on the performance of a system without the regenerator (i.e. a simple cycle) is also examined. In addition, the influence of bypass of some of the exhaust gas on the performance of the gas turbine, especially the regenerative cycle gas turbine, is evaluated.

  6. How to optimize brand awareness through non-administrated social channels in a two-sided network

    OpenAIRE

    Arozin, Alexander

    2016-01-01

    The effects of social media on digital branding is analysed in this paper, to establish how to optimize brand awareness through non-administrated social media channels in a two-sided network. This is a relatively unexplored field which may prove to be important for future businesses. Different levels of cooperation between brands are increasing and the implementation of two-sided networks are becoming standardized. A new way of differentiation is needed for the ever changing field of social m...

  7. A Novel Method for Intraoral Access to the Superior Head of the Human Lateral Pterygoid Muscle

    Directory of Open Access Journals (Sweden)

    Aleli Tôrres Oliveira

    2014-01-01

    Full Text Available Background. The uncoordinated activity of the superior and inferior parts of the lateral pterygoid muscle (LPM has been suggested to be one of the causes of temporomandibular joint (TMJ disc displacement. A therapy for this muscle disorder is the injection of botulinum toxin (BTX, of the LPM. However, there is a potential risk of side effects with the injection guide methods currently available. In addition, they do not permit appropriate differentiation between the two bellies of the muscle. Herein, a novel method is presented to provide intraoral access to the superior head of the human LPM with maximal control and minimal hazards. Methods. Computational tomography along with digital imaging software programs and rapid prototyping techniques were used to create a rapid prototyped guide to orient BTX injections in the superior LPM. Results. The method proved to be feasible and reliable. Furthermore, when tested in one volunteer it allowed precise access to the upper head of LPM, without producing side effects. Conclusions. The prototyped guide presented in this paper is a novel tool that provides intraoral access to the superior head of the LPM. Further studies will be necessary to test the efficacy and validate this method in a larger cohort of subjects.

  8. Intravitreal injection therapy in the treatment of noninfectious uveitis.

    Science.gov (United States)

    Modorati, Giulio; Miserocchi, Elisabetta

    2012-01-01

    Uveitis is responsible for 5-20% of legal blindness in the United States and in Europe. In noninfectious uveitis, the most frequent uveitic complication that endangers sight is cystoid macular edema. Clinical characteristics, inflammation grading and visual acuity determine the choice of the correct therapy for each patient. We can utilize drugs either alone or in combination using different dosages and routes of administration. Intravitreal injection directly into the vitreous cavity leads to rapid therapeutic drug concentration in the retinal tissue and reduces systemic side effects. Intravitreally injected triamcinolone acetonide is the most powerful drug for the treatment of cystoid macular edema related to intraocular inflammation, but it also causes the most frequent and serious side effects. Due to the numerous side effects associated with the use of corticosteroids, there is a need to identify other anti-inflammatory agents with a better safety profile. Recent studies have demonstrated that intravitreal immunosuppressant injections of methotrexate or anti-VEGF agents may lead to fewer intraocular side effects, but also have a lower therapeutic activity for the reduction of macular edema. At present, intraocular anti-TNF-α drugs do not show promising results. As regards nonsteroidal anti-inflammatory drugs, further data are necessary to fully understand their efficacy and potential side effects. Copyright © 2012 S. Karger AG, Basel.

  9. Method of controlling injection of oxygen into hydrogen-rich fuel cell feed stream

    Science.gov (United States)

    Meltser, Mark Alexander; Gutowski, Stanley; Weisbrod, Kirk

    2001-01-01

    A method of operating a H.sub.2 --O.sub.2 fuel cell fueled by hydrogen-rich fuel stream containing CO. The CO content is reduced to acceptable levels by injecting oxygen into the fuel gas stream. The amount of oxygen injected is controlled in relation to the CO content of the fuel gas, by a control strategy that involves (a) determining the CO content of the fuel stream at a first injection rate, (b) increasing the O.sub.2 injection rate, (c) determining the CO content of the stream at the higher injection rate, (d) further increasing the O.sub.2 injection rate if the second measured CO content is lower than the first measured CO content or reducing the O.sub.2 injection rate if the second measured CO content is greater than the first measured CO content, and (e) repeating steps a-d as needed to optimize CO consumption and minimize H.sub.2 consumption.

  10. Supercritical heat transfer in an annular channel with two-sided heaing

    International Nuclear Information System (INIS)

    Sergeev, V.V.; Remizov, O.V.; Gal'chenko, Eh.F.

    1986-01-01

    The paper deals with experimental inestigation into worsening of heat transfer at forced up flow in steam-water mixture in a vertical annular channel with two-sided heating and development of technique for calculation of supercritical heat exchange in this channel. Bench-scale experiments are carried out at high-pressure at mass rates of the coolant equal to 300-865 kg/(m 2 x s), pressure of 9.8-17.8 MPa and heat flux on the internal surface - 20-400 kW/m 2 , on the external surface - 35-450 kW/m 2 . Technique for calculation of supercritical heat exchange in channels with one- and two-sided heating is suggested. Analysis of the obtained experimental data permits to determine conditions for arising departure nucleate boiling on the internal and external surfaces and on both surfaces simultaneously. It is concluded that the suggested technique of calculation adequately reflects the effect of regime parameters of coolant flow on temperature regime of heat transferring surfaces in the supercritical area

  11. End Effects on the Linear Induction MHD Generator Calculated by Two-Sided Laplace Transform

    Energy Technology Data Exchange (ETDEWEB)

    Engeln, F.; Peschka, W. [Deutsche Versuchsanstalt fuer Luft- und Raumfahrt e.V., Institut fuer Energiewandlung und Elektrische Antriebe, Stuttgart, Federal Republic of Germany (Germany)

    1966-11-15

    In induction MHD systems special problems occur where the flow enters or leaves the magnetic field. These problems are generally described as end effects. Large gradients of the magnetic field are present at the inlet and also at the outlet of an MHD induction engine, these generating electric current systems in the fluid which may spoil the performance characteristics of the generator due to the interaction with the primary field of the engine. The two-dimensional induction MHD generator of finite length, using a polyphase winding system to obtain a travelling magnetic field, is treated as a boundary value problem by two-sided Laplace transform. For simplicity incompressibility is assumed. The two- dimensional boundary value problem of the induction engine is solved for - {infinity} Less-Than-Over-Equal-To x Less-Than-Over-Equal-To {infinity}. x is parallel to the flow direction of the linear MHD generator. In the region 0 Less-Than-Over-Equal-To x Less-Than-Over-Equal-To L the magnetic travelling wave is sinusoidal with a cyclical frequency {omega} and a phase-velocity v{sub s}. At x = 0 the conducting incompressible working fluid enters the field region and leaves it at the point-x = L. Two mathematical methods can be used to solve the boundary value problem, the Fourier transform or the two-sided Laplace transform. The latter offers the advantage of representing a complex analytical function in the image space. Moreover, it is possible to obtain the characteristics of the generator in the image space (e. g. field configuration, power flow function, etc.). That implies a large simplification of mathematical treatment. The solution in the original space then is given by asymptotic expansion of the known image function. (author)

  12. A new method to calculate pressure drop and shell-side heat transfer coefficient in a shell-and-tube heat exchanger

    International Nuclear Information System (INIS)

    Baptista Filho, B.D.; Konuk, A.A.

    1981-01-01

    A new method to calculate pressure drop (Δp) and shell-side heat transfer coefficient (h sub(c)) in a shell-and-tube heat exchanger with segmental baffles is presented. The method is based on the solution of the equations of conservation of mass and momentum between two baffles. The calculated distributions of pressure and velocities given respectively, Δp and h sub(c). The values of Δp and h sub(c) are correlated for a given geometry whit the shell side fluid properties and flow rate. The calculated and experimental results agree very well for a U-Tube heat exchanger. (Author) [pt

  13. Indirect two-sided relative ranking: a robust similarity measure for gene expression data

    Directory of Open Access Journals (Sweden)

    Licamele Louis

    2010-03-01

    Full Text Available Abstract Background There is a large amount of gene expression data that exists in the public domain. This data has been generated under a variety of experimental conditions. Unfortunately, these experimental variations have generally prevented researchers from accurately comparing and combining this wealth of data, which still hides many novel insights. Results In this paper we present a new method, which we refer to as indirect two-sided relative ranking, for comparing gene expression profiles that is robust to variations in experimental conditions. This method extends the current best approach, which is based on comparing the correlations of the up and down regulated genes, by introducing a comparison based on the correlations in rankings across the entire database. Because our method is robust to experimental variations, it allows a greater variety of gene expression data to be combined, which, as we show, leads to richer scientific discoveries. Conclusions We demonstrate the benefit of our proposed indirect method on several datasets. We first evaluate the ability of the indirect method to retrieve compounds with similar therapeutic effects across known experimental barriers, namely vehicle and batch effects, on two independent datasets (one private and one public. We show that our indirect method is able to significantly improve upon the previous state-of-the-art method with a substantial improvement in recall at rank 10 of 97.03% and 49.44%, on each dataset, respectively. Next, we demonstrate that our indirect method results in improved accuracy for classification in several additional datasets. These datasets demonstrate the use of our indirect method for classifying cancer subtypes, predicting drug sensitivity/resistance, and classifying (related cell types. Even in the absence of a known (i.e., labeled experimental barrier, the improvement of the indirect method in each of these datasets is statistically significant.

  14. Side effects and potential risk factors of botulinum toxin type A intramuscular injections in knee flexion contractures of hemophiliacs.

    Science.gov (United States)

    Rodriguez-Merchan, E Carlos; De la Corte-Rodriguez, Hortensia

    2017-07-01

    Knee flexion contracture (KFC) is a common complication of recurrent hemarthrosis in children and young adults with hemophilia. If the KFC is not prevented (by means of primary prophylaxis) and treated properly and early (be means of physical medicine and rehabilitation), it will become fixed. Areas covered: The aim of this article is to review the potential role of botulinum toxin type A (BTX-A) intramuscular injections for the treatment of KFC in people with hemophilia (PWH). Expert commentary: Although two recent reports have mentioned the benefits of intramuscular injections of BTX-A in PWH with KFC, the data are still scant and too preliminary. The use of intramuscular injections of BTX-A in PWH today should not be recommended until more case studies/small series (ideally well-designed clinical trials) fully demonstrate that this is safe and effective. The risks of intramuscular injections to a hemophilia patient cannot be underestimated (iatrogenic muscle hematomas and pseudotumors). This paper calls the attention of hemophilia treaters on the potential risks of this apparently interesting technique. The current use of BTX-A intramuscular injections in KFC of PWH could make no sense. Raising false expectations in these patients should be avoided.

  15. VALUE-ADDED SERVICE INVESTING AND PRICING STRATEGIES FOR A TWO-SIDED PLATFORM UNDER INVESTING RESOURCE CONSTRAINT

    Institute of Scientific and Technical Information of China (English)

    Guowei Dou; Ping He

    2017-01-01

    Investing on value-added service (VAS) amplifies users' participation and platform profit.However,the investing resource is usually limited in practice.This paper investigates VAS investing and pricing strategies for a two-sided platform under investing resource constraint.We reveal that with VAS investment,Subsidizing can still be done to enlarge users' demand,even when the investing cost becomes higher.For optimal pricing strategies,the network effect will be the dominating determinant if the gap between two marginal cross-side benefits (i.e.the benefit that users obtain when each new user join the other side of the platform) is large.Interestingly,we show that with the increase of the marginal investing cost,users might either be priced higher or lower.If the marginal investing cost increases to a high level,and the gap between the two marginal cross-side benefits is large,lowering the access fee for users possessing the higher cross-side network effect does not necessarily compensate more profit loss caused by higher cost.Moreover,after VAS is developed,raising the access fee for those whose marginal investing benefit is large does not necessarily generate more profit as well.The opposite strategy further enlarges users' utility,and promotes the investment to benefit more users.

  16. The Injection System of SAGA Light Source

    CERN Document Server

    Iwasaki, Yoshitaka; Ohgaki, Hideaki; Okajima, Toshihiro; Takabayashi, Yuichi; Tomimasu, Takio; Yoshida, Katuhide

    2005-01-01

    Saga light Source is a 1.4-GeV electron storage ring with a circumference of 75.6m. The injector is a 250-MeV linac producing 1 ms macro-pulse with a peak current of 12mA and repetition rate of 1Hz. The output beam from the linac is transported though a transport line, and injected into the ring though a septum magnet with a bending angle of 20-degree. The transport line consists of two bending magnets, two quadrupole doublelets, and a quadrupole singlet. The bump orbit is formed by four kicker magnets, two of which are installed at both sides of septum magnet, and other two are positioned apart by one magnet cell of the ring. They are excited by sinusoidal electric currents with a half width of 0.5 ms. The beam optics for the injection trajectory is computed and shown at control room, the parameters for which are provided directly from the power supply control server PC. The operator is able to see real-time result of the beam trajectory calculation. This tool is quite effective to optimize the magnets param...

  17. Immunological effects of CaEDTA injection: observations in two lead workers.

    Science.gov (United States)

    Sata, F; Araki, S; Sakai, T; Nakata, A; Yamashita, K; Morita, Y; Tanigawa, T; Miki, A

    1997-12-01

    To evaluate the effects of calcium disodium ethylenediamine tetraacetate (CaEDTA) injection on human immune system in relation to exposure to lead, we administered CaEDTA by intravenous injection for 1 hr three times (three consecutive days) a week to two male lead workers. They had been engaged in recycling lead for 31 and 22 years, aged 61 and 53 years (workers 1 and 2), respectively. Before the treatment of CaEDTA, their blood lead concentrations (PbB) were 81 and 68 micrograms/dl, respectively. The administration of CaEDTA had been carried out to worker 1 for 10 weeks and to worker 2 for 6 weeks. A significant decrease in PbB between before and after three-times CaEDTA injection was found in both workers. Significant increases in IgG, IgA, IgM, CD8+, and CD57+ cells were found in worker 1. A significant increase in IgD was found in worker 2. During the study period, IgG in worker 1 and CD4+ cells in worker 2 were gradually increasing. There was a significant negative correlation between IgG and PbB in worker 1. It is suggested that the immunological function such as antibody formation in lead workers might be improved by CaEDTA injection.

  18. Experimental study of curved guide tubes for pellet injection

    International Nuclear Information System (INIS)

    Combs, S.K.; Baylor, L.R.; Foust, C.R.; Gouge, M.J.; Jernigan, T.C.; Milora, S.L.

    1997-01-01

    The use of curved guide tubes for transporting frozen hydrogen pellets offers great flexibility for pellet injection into plasma devices. While this technique has been previously employed, an increased interest in its applicability has been generated with the recent ASDEX Upgrade experimental data for magnetic high-field side (HFS) pellet injection. In these innovative experiments, the pellet penetration appeared to be significantly deeper than for the standard magnetic low-field side injection scheme, along with corresponding greater fueling efficiencies. Thus, some of the major experimental fusion devices are planning experiments with HFS pellet injection. Because of the complex geometries of experimental fusion devices, installations with multiple curved guide tube sections will be required for HFS pellet injection. To more thoroughly understand and document the capability of curved guide tubes, an experimental study is under way at the Oak Ridge National Laboratory (ORNL). In particular, configurations and pellet parameters applicable for the DIII-D tokamak and the International Thermonuclear Experimental Reactor (ITER) were simulated in laboratory experiments. Initial test results with nominal 2.7- and 10-mm-diam deuterium pellets are presented and discussed

  19. Two-stroke engine with gaseous and liquid fuel injection

    Energy Technology Data Exchange (ETDEWEB)

    Laursen, Rene Sejer [MAN Diesel and Turbo SE, Copenhagen (Denmark)

    2012-08-15

    The need to lower emissions of CO{sub 2}, NO{sub x}, SO{sub x} and particulates as well as rising oil prices have increased engine operators' interest in alternative fuels and fuel flexibility. The low speed two-stroke ME-GI and ME-LGI dual-fuel engines with diesel pilot injection from MAN Diesel and Turbo offer the opportunity of utilising fuels such as LNG, LPG, and methanol in a wide range of liquid to gaseous fuel ratios. (orig.)

  20. Method of injecting iron ion into reactor coolant

    International Nuclear Information System (INIS)

    Ito, Kazuyuki; Sawa, Toshio; Nishino, Yoshitaka; Adachi, Tetsuro; Osumi, Katsumi.

    1988-01-01

    Purpose: To form iron ions stably and inject them into nuclear reactor coolants with no substantial degradation of the severe water quality conditions for reactor coolants. Method: Iron ions are formed by spontaneous corrosion of iron type materials and electroconductivity is increased with the iron ions. Then, the liquids are introduced into an electrolysis vessel using iron type material as electrodes and, thereafter, incorporation of newly added ions other than the iron ions are prevented by supplying electric current. Further, by retaining the iron type material in the packing vessel by the magnetic force therein, only the iron ions are flow out substantially from the packing vessel while preventing the discharge of iron type materials per se or solid corrosion products and then introduced into the electrolysis vessel. Powdery or granular pure iron or carbon steel is used as the iron type material. Thus, iron ions and hydroxides thereof can be injected into coolants by using reactor water at low electroconductivity and incapable of electrolysis. (Kamimura, M.)

  1. To study the effect of injection dexmedetomidine for prevention of pain due to propofol injection and to compare it with injection lignocaine

    Directory of Open Access Journals (Sweden)

    Manisha Sapate

    2015-12-01

    Full Text Available BACKGROUND: Pain due to injection propofol is a common problem. Different methods are used to decrease the pain but with limited success. The objective of this study was to assess the effect of injection dexmedetomidine 0.2 mcg/kg for prevention of pain due to propofol injection and compare it with injection lignocaine 0.2 mg/kg. METHOD: After taking permission of the Institutional Ethical Committee, written informed consent was obtained from all patients, in a randomized prospective study. 60 American Society of Anesthesiology I and II patients of age range 20-60 years of either sex posted for elective surgeries under general anaesthesia were randomly allocated into two groups. Group I (dexmedetomidine group: Inj. dexmedetomidine 0.2 mcg/kg diluted in 5 mL normal saline and Group II (lignocaine group: Inj. lignocaine 0.2 mg/kg diluted in 5 mL normal saline. IV line was secured with 20 G cannula and venous occlusion was applied to forearm using a pneumatic tourniquet and inflated to 70 mm Hg for 1 min. Study drug was injected, tourniquet released and then 25% of the calculated dose of propofol was given intravenously over 10 s. After 10 s of injection, severity of pain was evaluated using McCrirrick and Hunter scale and then remaining propofol and neuromuscular blocking agent was given. Endotracheal intubation was done and anaesthesia was maintained on O2, N2O and isoflurane on intermittent positive pressure ventilation with Bain's circuit and inj. vecuronium was used as muscle relaxant. RESULTS: Demographic data showed that there was no statistically significant difference between the 2 groups. There was no statistically significant difference between 2 groups in respect to inj. propofol pain. No adverse effects like oedema, pain, wheal response at the site of injection were observed in the two groups.

  2. Ultrasound guided versus landmark guided corticosteroid injection in patients with rotator cuff syndrome: Randomised controlled trial.

    Science.gov (United States)

    Bhayana, Himanshu; Mishra, Puneet; Tandon, Anupama; Pankaj, Amite; Pandey, Rohit; Malhotra, Raskesh

    2018-03-01

    Impingement syndrome is the most common differential in a patient presenting to an orthopaedic OPD with shoulder pain. Impingement syndrome is often managed with subacromial corticosteroid injection, which can be instilled using either landmark guided (LMG) approach or with the assistance of ultrasound (US). This study was envisaged to enquire whether ultrasound assistance improves the accuracy, efficacy or safety profile of the injection. 60 patients of rotator cuff syndrome underwent diagnostic ultrasound. They were randomly assigned to receive subacromial injection of 2 ml (40 mg/ml) methylprenisolone and 2 ml of 1% lignocaine combination either by US assistance (n = 30) or using LMG assistance (n = 30). The patients were evaluated before injection and on follow up visits at day 5, week 3, week 6 and 3rd month by a single assessor. The assessor was blinded of the treatment group to which patient belonged. Clinical assessment included demographic and clinical data, accuracy of injection, VAS (0-100) for pain, Constant score with goniometer evaluation of range of motion, patient's self assessment proforma and post injection side effects if any. Initial demographic, clinical and US findings in the groups exhibited no significant differences. The accuracy of US guided injections (100%) was more when compared from LMG injection (93.3%). Both VAS and Constant score showed significant improvement following steroid injection up to 3 months of follow up. However the differences in the two groups were not significant suggesting comparable efficacy of the two approaches. (Mean VAS score decrease: 27.23 for US and 25.16 for LMG, p guided injections have a higher accuracy of drug placement in the subacromial bursa, there is no difference in terms of clinical outcomes or safety profile of either of the method. Hence US guided injections seems to be unjustified, when compared to equally efficacious and cost effective LMG steroid injection.

  3. The theory and method of two-well field test for in-situ leaching uranium

    International Nuclear Information System (INIS)

    Yao Yixuan; Huo Jiandang; Xiang Qiulin; Tang Baobin

    2007-01-01

    Because leaching area in field test for in-situ leaching uranium is not accounted exactly, the reliability of obtaining parameters by calculating can not be ensured, and the whole test needs a long time and great investment. In two-well field test, lixiviant is injected from one well, pregnant solution is pumped out from the other, flow rate of the production well is more than that of the injection well, and uranium is not recoveried. In the case of keeping invariable ratio of pumping capacity to injecting capacity during the testing process, leaching area is not variable, can be exactly calculated. The full field test needs six months to one year. Two-well test is a scientific, rapid, minimal spending field test method, and is widely used in Commonwealth of Independent States. (authors)

  4. Towards Automated Bargaining in Electronic Markets: A Partially Two-Sided Competition Model

    Science.gov (United States)

    Gatti, Nicola; Lazaric, Alessandro; Restelli, Marcello

    This paper focuses on the prominent issue of automating bargaining agents within electronic markets. Models of bargaining in literature deal with settings wherein there are only two agents and no model satisfactorily captures settings in which there is competition among buyers, being they more than one, and analogously among sellers. In this paper, we extend the principal bargaining protocol, i.e. the alternating-offers protocol, to capture bargaining in markets. The model we propose is such that, in presence of a unique buyer and a unique seller, agents' equilibrium strategies are those in the original protocol. Moreover, we game theoretically study the considered game providing the following results: in presence of one-sided competition (more buyers and one seller or vice versa) we provide agents' equilibrium strategies for all the values of the parameters, in presence of two-sided competition (more buyers and more sellers) we provide an algorithm that produce agents' equilibrium strategies for a large set of the parameters and we experimentally evaluate its effectiveness.

  5. Zinc injection method and device in nuclear power plant

    International Nuclear Information System (INIS)

    Maehara, Kazumi; Negishi, Itaru; Deguchi, Tatsuya; Ino, Takao; Sasaki, Noriyuki; Yotsuyanagi, Tadashi; Tobara, Hirotaka.

    1996-01-01

    The present invention concerns a method of injecting zinc into reactor water, and it can supply a solution of zinc at a high concentration by improving the solubility of zinc. Namely, zinc is used as a solute and is dissolved in an aqueous solution containing an electrolyte such as carbonic acid. The resultant zinc solution at a high concentration is injected to reactor water. In the device of the present invention, (1) a dissolution vessel for dissolving zinc comprises a zinc supply means at an upper portion thereof and a carbonic acid gas supply means at a lower portion, (2) an injection means supplies the solution in which zinc is dissolved at a high concentration to reactor water. An aqueous solution saturated with a carbonic acid gas is used as a solvent for dissolving zinc into reactor water at a high concentration. The dissolution vessel has a gas diffusion pipe at the bottom for introducing the carbonic acid gas and has a stirrer in the inside. Zinc is supplied continuously or discontinuously. Raw material zinc may be in the form of a plate, rod, granule, or powder, however, powdery zinc is preferably used. (I.S.)

  6. Extraction method of interfacial injected charges for SiC power MOSFETs

    Science.gov (United States)

    Wei, Jiaxing; Liu, Siyang; Li, Sheng; Song, Haiyang; Chen, Xin; Li, Ting; Fang, Jiong; Sun, Weifeng

    2018-01-01

    An improved novel extraction method which can characterize the injected charges along the gate oxide interface for silicon carbide (SiC) power metal-oxide-semiconductor field-effect transistors (MOSFETs) is proposed. According to the different interface situations of the channel region and the junction FET (JFET) region, the gate capacitance versus gate voltage (Cg-Vg) curve of the device can be divided into three relatively independent parts, through which the locations and the types of the charges injected in to the oxide above the interface can be distinguished. Moreover, the densities of these charges can also be calculated by the amplitudes of the shifts in the Cg-Vg curve. The correctness of this method is proved by TCAD simulations. Moreover, experiments on devices stressed by unclamped-inductive-switching (UIS) stress and negative bias temperature stress (NBTS) are performed to verify the validity of this method.

  7. Experimental Investigation of Diffuser Hub Injection to Improve Centrifugal Compressor Stability

    Science.gov (United States)

    Skoch, Gary J.

    2004-01-01

    Results from a series of experiments to investigate whether centrifugal compressor stability could be improved by injecting air through the diffuser hub surface are reported. The research was conducted in a 4:1 pressure ratio centrifugal compressor configured with a vane-island diffuser. Injector nozzles were located just upstream of the leading edge of the diffuser vanes. Nozzle orientations were set to produce injected streams angled at 8, 0 and +8 degrees relative to the vane mean camber line. Several injection flow rates were tested using both an external air supply and recirculation from the diffuser exit. Compressor flow range did not improve at any injection flow rate that was tested. Compressor flow range did improve slightly at zero injection due to the flow resistance created by injector openings on the hub surface. Leading edge loading and semi-vaneless space diffusion showed trends similar to those reported earlier from shroud surface experiments that did improve compressor flow range. Opposite trends are seen for hub injection cases where compressor flow range decreased. The hub injection data further explain the range improvement provided by shroud-side injection and suggest that different hub-side techniques may produce range improvement in centrifugal compressors.

  8. Comparison of Flow Injection MS, NMR, and DNA Sequencing: Methods for Identification and Authentication of Black Cohosh (Actaea racemosa)

    Science.gov (United States)

    Flow injection mass spectrometry (FIMS) and proton nuclear magnetic resonance spectrometry (1H-NMR), two metabolic fingerprinting methods, and DNA sequencing were used to identify and authenticate Actaea species. Initially, samples of Actaea racemosa L. from a single source were distinguished from ...

  9. An evaluation of a new N-isopropyl-p-[123I] iodoamphetamine double injection method for acetazolamide testing

    International Nuclear Information System (INIS)

    Mori, Kentaro; Maeda, Minoru; Asegawa, Satoshi; Masuda, Yoko.

    1994-01-01

    To evaluate the capacity of the cerebrovascular reserve, the acetazolamide test must be used to quantitatively measure the cerebral blood flow (CBF) before and after the administration of acetazolamide. Previously, the authors have explained the rationale for using 5 min SPECT images to quantify the CBF with N-isoprophyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP), and in this study they describe how they devised a 123 I-IMP double injection method for use with the acetazolamide test, and report on the clinical results. First, We measured the brain and arterial 123 I concentrations 10 normal subjects after a 123 I-IMP injection, and noted that after 25 minutes the brain and arterial blood activity had plateaued and stabilized. Thus, by using the background substraction method, We found it possible to quantitatively measure the CBF twice in 30 minutes and have called this technique the double injection method. We have clinically used this double injection method for evaluating the CBF in 5 lacunar stroke patients with no major arterial occlusion and found no statistically significant difference in the CBF values between the first and second CBF measurements. They then applied this double injection method for the acetazolamide testing of 10 stroke patients with an arterial occlusion of stenosis and found that the CBF results compared favorably with the CBF results achieved with the use of the separate injection method. It also should be noted the double injection method was successfully used for clinical CBF measurements without acetazolamide testing. (author)

  10. Single-sided NMR

    CERN Document Server

    Casanova, Federico; Blümich, Bernhard

    2011-01-01

    Single-Sided NMR describes the design of the first functioning single-sided tomograph, the related measurement methods, and a number of applications. One of the key advantages to this method is the speed at which the images are obtained.

  11. New once-a-month injectable contraceptives, with particular reference to Cyclofem/Cyclo-Provera.

    Science.gov (United States)

    Hall, P E

    1998-08-01

    Once-a-month injectable contraceptives containing a progestogen and an estrogen have been developed that disrupt vaginal bleeding patterns less than the widely used progestogen-only preparations. Pharmacokinetic studies were undertaken of dosages and ratios of the progestogens and the respective estrogens. In Phase III clinical trials, annual pregnancy rates were below 0.4% for Mesigyna (norethisterone enanthate/estradiol valerate, Schering AG, Berlin, Germany) and below 0.2% for Cyclofem (MPA/E2C) (medroxyprogesterone acetate/estradiol cypionate, Aplicaciones Farmaceuticas, SA, Mexico and PT Tunggal, Indonesia). More than two-thirds of women had predictable, regular cycles, and discontinuation due to bleeding-related problems occurred less than half as often as with progestogen-only injectables. With MPA/E2C, return to fertility is similar to that observed with other hormonal or intrauterine methods, and both products have little effect on lipids or hemostasis. Introductory trials of MPA/E2C in 12000 women with 100000 woman-months of experience confirmed the high efficacy of the product in routine use. The use of MPA/E2C in a non-reusable injection device, Uniject (Becton Dickinson, Franklin Lakes, NJ) is discussed. Once-a-month hormonal contraceptives have been shown to provide a safe contraceptive option for all women and an alternative for women who wish to use injectable formulations that cause less disruption in vaginal bleeding and minimal side effects.

  12. Botulinum Toxin Type A Injections in the Psoas Muscle of Children with Cerebral Palsy: Muscle Atrophy after Motor End Plate-Targeted Injections

    Science.gov (United States)

    Van Campenhout, Anja; Verhaegen, Ann; Pans, Steven; Molenaers, Guy

    2013-01-01

    MEP targeting during BoNT-A injections has been demonstrated to improve outcome. Two injection techniques of the psoas muscle--proximal MEP targeting versus a widely used more distal injection technique--are compared using muscle volume assessment by digital MRI segmentation as outcome measure. Method: 7 spastic diplegic children received…

  13. The filter of choice: filtration method preference among injecting drug users

    Directory of Open Access Journals (Sweden)

    Keijzer Lenneke

    2011-08-01

    Full Text Available Abstract Background Injection drug use syringe filters (IDUSF are designed to prevent several complications related to the injection of drugs. Due to their small pore size, their use can reduce the solution's insoluble particle content and thus diminish the prevalence of phlebitis, talcosis.... Their low drug retention discourages from filter reuse and sharing and can thus prevent viral and microbial infections. In France, drug users have access to sterile cotton filters for 15 years and to an IDUSF (the Sterifilt® for 5 years. This study was set up to explore the factors influencing filter preference amongst injecting drug users. Methods Quantitative and qualitative data were gathered through 241 questionnaires and the participation of 23 people in focus groups. Results Factors found to significantly influence filter preference were duration and frequency of injecting drug use, the type of drugs injected and subculture. Furthermore, IDU's rationale for the preference of one type of filter over others was explored. It was found that filter preference depends on perceived health benefits (reduced harms, prevention of vein damage, protection of injection sites, drug retention (low retention: better high, protective mechanism against the reuse of filters; high retention: filter reuse as a protective mechanism against withdrawal, technical and practical issues (filter clogging, ease of use, time needed to prepare an injection and believes (the conviction that a clear solution contains less active compound. Conclusion It was concluded that the factors influencing filter preference are in favour of change; a shift towards the use of more efficient filters can be made through increased availability, information and demonstrations.

  14. Treatment of nail psoriasis with a modified regimen of steroid injections

    International Nuclear Information System (INIS)

    Saleem, K.; Azim, W.

    2008-01-01

    To evaluate the efficacy of a modified regimen of intralesional steroid injection therapy for the treatment of nail psoriasis and assess the side effects of this regimen. Patients having psoriatic nail dystrophy, reporting to the skin department of Military Hospital, Rawalpindi were registered. The features accounted for were pitting, onycholysis, subungual hyperkeratosis, ridging, thickening and color change. The affected digits were scored from 0 to 3 for the severity of each of these features. Similar number of control digits was also selected. Injection of triamcinolone acetonide (10 mg/ml) was given into the nail bed and matrix following ring block anesthesia. The features were re-scored after two months. A second injection was given after 02 months if warranted by poor response. The follow-up period ranged upto 06 months. A total of 100 nails were injected in 35 subjects. Pitting was the commonest presenting feature seen in 71 digits (71%) and improved in 41 digits (57.7%). Onycholysis was seen in 37 digits (37%) and improved in 15 digits (40.5%). Subungual hyperkeratosis was seen in 57 digits (57%) and improved in all the cases. Other features like longitudinal ridging, thickening and yellow oil drop-like discoloration showed marked improvement. The side effects of this regimen were minimal and included painless subungual hematoma. The modified regimen of steroid was found to be effective and safe for the treatment of psoriatic nail deformities in this series. (author)

  15. Influence of Injector Location on Part-Load Performance Characteristics of Natural Gas Direct-Injection in a Spark Ignition Engine

    Energy Technology Data Exchange (ETDEWEB)

    Sevik, James [Argonne National Lab. (ANL), Argonne, IL (United States); Pamminger, Michael [Argonne National Lab. (ANL), Argonne, IL (United States); Wallner, Thomas [Argonne National Lab. (ANL), Argonne, IL (United States); Scarcelli, Riccardo [Argonne National Lab. (ANL), Argonne, IL (United States); Boyer, Brad [Ford Motor Co., Detroit, MI (United States); Wooldridge, Steven [Ford Motor Co., Detroit, MI (United States); Hall, Carrie [Illinois Inst. of Technology, Chicago, IL (United States); Miers, Scott [Michigan Technological Univ., Houghton, MI (United States)

    2016-04-05

    Interest in natural gas as an alternative fuel source to petroleum fuels for light-duty vehicle applications has increased due to its domestic availability and stable price compared to gasoline. With its higher hydrogen-to-carbon ratio, natural gas has the potential to reduce engine out carbon dioxide emissions, which has shown to be a strong greenhouse gas contributor. For part-load conditions, the lower flame speeds of natural gas can lead to an increased duration in the inflammation process with traditional port-injection. Direct-injection of natural gas can increase in-cylinder turbulence and has the potential to reduce problems typically associated with port-injection of natural gas, such as lower flame speeds and poor dilution tolerance. A study was designed and executed to investigate the effects of direct-injection of natural gas at part-load conditions. Steady-state tests were performed on a single-cylinder research engine representative of current gasoline direct-injection engines. Tests were performed with direct-injection in the central and side location. The start of injection was varied under stoichiometric conditions in order to study the effects on the mixture formation process. In addition, exhaust gas recirculation was introduced at select conditions in order to investigate the dilution tolerance. Relevant combustion metrics were then analyzed for each scenario. Experimental results suggest that regardless of the injector location, varying the start of injection has a strong impact on the mixture formation process. Delaying the start of injection from 300 to 120°CA BTDC can reduce the early flame development process by nearly 15°CA. While injecting into the cylinder after the intake valves have closed has shown to produce the fastest combustion process, this does not necessarily lead to the highest efficiency, due to increases in pumping and wall heat losses. When comparing the two injection configurations, the side location shows the best

  16. Chitosan Oligosaccharide Reduces Propofol Requirements and Propofol-Related Side Effects

    Directory of Open Access Journals (Sweden)

    Zhiwen Li

    2016-12-01

    Full Text Available Propofol is one of the main sedatives but its negative side effects limit its clinical application. Chitosan oligosaccharide (COS, a kind of natural product with anti-pain and anti-inflammatory activities, may be a potential adjuvant to propofol use. A total of 94 patients receiving surgeries were evenly and randomly assigned to two groups: 10 mg/kg COS oral administration and/or placebo oral administration before being injected with propofol. The target-controlled infusion of propofol was adjusted to maintain the values of the bispectral index at 50. All patients’ pain was evaluated on a four-point scale and side effects were investigated. To explore the molecular mechanism for the functions of COS in propofol use, a mouse pain model was established. The activities of Nav1.7 were analyzed in dorsal root ganglia (DRG cells. The results showed that the patients receiving COS pretreatment were likely to require less propofol than the patients pretreated with placebo for maintaining an anesthetic situation (p < 0.05. The degrees of injection pain were lower in a COS-pretreated group than in a propofol-pretreated group. The side effects were also more reduced in a COS-treated group than in a placebo-pretreated group. COS reduced the activity of Nav1.7 and its inhibitory function was lost when Nav1.7 was silenced (p > 0.05. COS improved propofol performance by affecting Nav1.7 activity. Thus, COS is a potential adjuvant to propofol use in surgical anesthesia.

  17. The position of lingula as an index for inferior alveolar nerve block injection in 7-11-year-old children.

    Science.gov (United States)

    Ezoddini Ardakani, Fatemeh; Bahrololoumi, Zahra; Zangouie Booshehri, Maryam; Navab Azam, Alireza; Ayatollahi, Fatemeh

    2010-01-01

    Inferior alveolar nerve block injection is one of the common intra oral anesthetic techniques, with a failure rate of 15-20%. The aim of this study was to evaluate the position of the lingula as an index for this injection. Thirty eight panoramic radiographs of 7-11 year old patients were analyzed and the distance between the lingula index and occlusal plane was measured. Then, lower alveolar nerve block injection was performed on 88 children. Finally, a visual analogue scale was used to measure the rate of pain in the patients. This distance increased with age and in children younger than nine years is -0.45 mm on the right side and -0.95 mm on the left side. This distance in children older than 9 years is -0.23 mm on the right side and 0.47 mm on the left side. The success rates of inferior alveolar nerve block injection based on lingual index were 49% on the right side and 53.8% on the left side. As the lingual index has various positions and its distance from the occlusal plane increases with age, it is not an appropriate landmark for inferior alveolar nerve block injection.

  18. Spectral-Domain Measurement of Strain Sensitivity of a Two-Mode Birefringent Side-Hole Fiber

    Directory of Open Access Journals (Sweden)

    Waclaw Urbanczyk

    2012-09-01

    Full Text Available The strain sensitivity of a two-mode birefringent side-hole fiber is measured in the spectral domain. In a simple experimental setup comprising a broadband source, a polarizer, a two-mode birefringent side-hole fiber under varied elongations, an analyzer and a compact spectrometer, the spectral interferograms are resolved. These are characterized by the equalization wavelength at which spectral interference fringes have the highest visibility (the largest period due to the zero group optical path difference between the fundamental, the LP01 mode and the higher-order, the LP11 mode. The spectral interferograms with the equalization wavelength are processed to retrieve the phase as a function of the wavelength. From the retrieved phase functions corresponding to different elongations of a two-mode birefringent side-hole fiber under test, the spectral strain sensitivity is obtained. Using this approach, the intermodal spectral strain sensitivity was measured for both x and y polarizations. Moreover, the spectral polarimetric sensitivity to strain was measured for the fundamental mode when a birefringent delay line was used in tandem with the fiber. Its spectral dependence was also compared with that obtained from a shift of the spectral interferograms not including the equalization wavelength, and good agreement was confirmed.

  19. A spilt head study of efficacy of placebo versus platelet-rich plasma injections in the treatment of androgenic alopecia

    Directory of Open Access Journals (Sweden)

    Dilip Kachhawa

    2017-01-01

    Full Text Available Background: Platelet-rich plasma (PRP is an autologous concentration of human platelets contained in a small volume of plasma with haemostatic and tissue repairing effects. Being enriched by various growth factors, PRP has become the focus of attention in numerous fields of medicine. Androgenic alopecia (AGA is a common chronic hair loss disorder, characterised by progressive hair loss. Despite the therapeutic options available, there is low patient compliance and satisfaction rate. The topical and often systemic adverse effects of therapy has lead to the search of new treatment options for AGA. Recently, PRP has received growing attention as a potential therapeutic tool for hair loss. Aim: To compare the efficacy of placebo versus PRP injections in the treatment of male AGA. Patients and Methods: Fifty male patients with AGA (Grade III to VI were enrolled in the study. PRP was prepared using the double-spin method and injected in the androgen-related areas of scalp on the left side. Normal saline was injected on the right side in a similar fashion. Treatment sessions were performed with an interval of 21 days, and six sittings were completed for every patient. Results: Hair loss reduced with evidence of new hair growth. Digital image analysis showed an overall improvement in hair density and quality as lanugo-like hair became thicker, normal hair. An improvement in hair density, quality and thickness on trichoscopy was noted. Conclusion: Our data suggest that PRP injections have therapeutic effect on male pattern hair loss with no major side effects and high patient satisfaction overall.

  20. Integrative relational machine-learning for understanding drug side-effect profiles.

    Science.gov (United States)

    Bresso, Emmanuel; Grisoni, Renaud; Marchetti, Gino; Karaboga, Arnaud Sinan; Souchet, Michel; Devignes, Marie-Dominique; Smaïl-Tabbone, Malika

    2013-06-26

    Drug side effects represent a common reason for stopping drug development during clinical trials. Improving our ability to understand drug side effects is necessary to reduce attrition rates during drug development as well as the risk of discovering novel side effects in available drugs. Today, most investigations deal with isolated side effects and overlook possible redundancy and their frequent co-occurrence. In this work, drug annotations are collected from SIDER and DrugBank databases. Terms describing individual side effects reported in SIDER are clustered with a semantic similarity measure into term clusters (TCs). Maximal frequent itemsets are extracted from the resulting drug x TC binary table, leading to the identification of what we call side-effect profiles (SEPs). A SEP is defined as the longest combination of TCs which are shared by a significant number of drugs. Frequent SEPs are explored on the basis of integrated drug and target descriptors using two machine learning methods: decision-trees and inductive-logic programming. Although both methods yield explicit models, inductive-logic programming method performs relational learning and is able to exploit not only drug properties but also background knowledge. Learning efficiency is evaluated by cross-validation and direct testing with new molecules. Comparison of the two machine-learning methods shows that the inductive-logic-programming method displays a greater sensitivity than decision trees and successfully exploit background knowledge such as functional annotations and pathways of drug targets, thereby producing rich and expressive rules. All models and theories are available on a dedicated web site. Side effect profiles covering significant number of drugs have been extracted from a drug ×side-effect association table. Integration of background knowledge concerning both chemical and biological spaces has been combined with a relational learning method for discovering rules which explicitly

  1. Development of planning methods for demand-side management (DSM)

    International Nuclear Information System (INIS)

    Kaerkkaeinen, S.; Kekkonen, V.; Rissanen, P.

    1995-01-01

    The interest of utilities and governmental agencies in Demand-side management (IDSM) and Integrated Resource Planning (IRP) has increased during recent years also in Finland. From the governmental point of view, the main reason for this has been concern about the environmental effects of electricity supply and consumption. Utilities are mainly interested in cost reductions in electricity supply and distribution caused by DSM. Also improved service to the customer due to DSM has increasing value to utilities. In this project, the main target has been to develop and assess methods for DSM planning from the utility point of view. The final goal is to integrate these methods into the strategic planning of electric utilities

  2. Method of determination of radiochemical purity of gallium-67 citrate injection

    International Nuclear Information System (INIS)

    Wang Quanji

    1985-01-01

    A simple method is used to compare the effect of five developing agents on the radiochemical purity of neutral products of 67 GaCit and on Rsub(f) values. Two preferable developing agents are recommended as suitable for the identification of 67 GaCit injection in its production. The effect of six pH values of different developing agents on radiochemical purity, Rsub(f) and chromatogram are compared for the neutral products. The results of the experiments show that the ascending paper chromatography with 1:2:4 pyridine/ethanol/water and 85:15 methanol/water is preferable for the determination of the radiochemical purity of 67 GaCit. The other developing agents also can be used if there are not any impurities except gallium radioisotopes

  3. Three-dimensional CT might be a potential evaluation modality in correction of asymmetrical masseter muscle hypertrophy by botulinum toxin injection.

    Science.gov (United States)

    No, Yeon A; Ahn, Byeong Heon; Kim, Beom Joon; Kim, Myeung Nam; Hong, Chang Kwon

    2016-01-01

    For correction of this asymmetrical hypertrophy, botulinum toxin type A (BTxA) injection is one of convenient treatment modalities. Unfortunately, physical examination of masseter muscle is not enough to estimate the exact volume of muscle hypertrophy difference. Two Koreans, male and female, of bilateral masseter hypertrophy with asymmetricity were evaluated. BTxA (NABOTA(®), Daewoong, Co. Ltd., Seoul, Korea) was injected at master muscle site with total 50 U (25 U at each side) and volume change was evaluated with three-dimensional (3D) CT image analysis. Maximum reduction of masseter hypertrophy was recognized at 2-month follow-up and reduced muscle size started to restore after 3 months. Mean reduction of masseter muscle volume was 36% compared with baseline. More hypertrophied side of masseter muscle presented 42% of volume reduction at 2-month follow-up but less hypertrophied side of masseter muscle showed 30% of volume shrinkage. In conclusion, 3D CT image analysis might be the exact evaluation tool for correction of asymmetrical masseter hypertrophy by botulinum toxin injection.

  4. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection

    Directory of Open Access Journals (Sweden)

    Sara Pourshahidi

    2008-04-01

    Full Text Available

    Background and aims. Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections.

    Materials and methods. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test.

    Results. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127 and between right and left injection sites (P = 0.778.

    Conclusion. According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  5. Optimisation of warpage on plastic injection moulding part using response surface methodology (RSM) and genetic algorithm method (GA)

    Science.gov (United States)

    Miza, A. T. N. A.; Shayfull, Z.; Nasir, S. M.; Fathullah, M.; Hazwan, M. H. M.

    2017-09-01

    In this study, Computer Aided Engineering was used for injection moulding simulation. The method of Design of experiment (DOE) was utilize according to the Latin Square orthogonal array. The relationship between the injection moulding parameters and warpage were identify based on the experimental data that used. Response Surface Methodology (RSM) was used as to validate the model accuracy. Then, the RSM and GA method were combine as to examine the optimum injection moulding process parameter. Therefore the optimisation of injection moulding is largely improve and the result shown an increasing accuracy and also reliability. The propose method by combining RSM and GA method also contribute in minimising the warpage from occur.

  6. Study of the method of water-injected meat identifying based on low-field nuclear magnetic resonance

    Science.gov (United States)

    Xu, Jianmei; Lin, Qing; Yang, Fang; Zheng, Zheng; Ai, Zhujun

    2018-01-01

    The aim of this study to apply low-field nuclear magnetic resonance technique was to study regular variation of the transverse relaxation spectral parameters of water-injected meat with the proportion of water injection. Based on this, the method of one-way ANOVA and discriminant analysis was used to analyse the differences between these parameters in the capacity of distinguishing water-injected proportion, and established a model for identifying water-injected meat. The results show that, except for T 21b, T 22e and T 23b, the other parameters of the T 2 relaxation spectrum changed regularly with the change of water-injected proportion. The ability of different parameters to distinguish water-injected proportion was different. Based on S, P 22 and T 23m as the prediction variable, the Fisher model and the Bayes model were established by discriminant analysis method, qualitative and quantitative classification of water-injected meat can be realized. The rate of correct discrimination of distinguished validation and cross validation were 88%, the model was stable.

  7. Percutaneous Ultrasound-Guided Thrombin Injection in Iatrogenic Arterial Pseudoaneurysms: Effectiveness and Complications

    International Nuclear Information System (INIS)

    Koh, Young Hwan; Kim, Hak Soo; Kim, Hyung Sik; Min, Seung Kee

    2005-01-01

    To evaluate and describe the efficacy and side effects of a percutaneous thrombin injection under ultrasonography guidance for the treatment of iatrogenic pseudo aneurysms Eighteen consecutive iatrogenic pseudo aneurysm cases were treated with a thrombin injection. The thrombin was injected into the pseudo aneurysm cavity using a 22-gauge needle under ultrasonographic guidance. The causes of the pseudo aneurysms are as follows: post coronary angiography (9 cases), percutaneous coronary balloon angioplasty (5 cases), cerebral angiography (1 case), transhepatic chemo embolization (1 case), percutaneous trans femoral arterial stent insertion (1 case) and bone marrow aspiration for a marrow transplant (1 case). Only one case required a secondary thrombin injection due to recurrent flow in the pseudo aneurysm lumen, which was detected at the follow up Doppler ultrasound. Other seventeen cases were successfully treated on the first trial. There were no technical failures or complication related to the procedure. The average amount of thrombin injected was 733 IU. Nine out of 18 treated patients (50%) showed mild reactions to the thrombin including mild fever (4 cases), chilling sensation (3 cases), a chilling sensation with mild dyspnea (1 case), mild chest discomfort (1 case) after the thrombin injection. All these side effects were transient and improved several hours later. All the iatrogenic pseudo aneurysms were treated successfully with an ultrasound-guided percutaneous thrombin injection. There was a high rate of hypersensitivity to the bovine thrombin, which precaution should be taken to prevent more serious side effects

  8. Percutaneous Ultrasound-Guided Thrombin Injection in Iatrogenic Arterial Pseudoaneurysms: Effectiveness and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Young Hwan [Boramae Hospital, Seoul (Korea, Republic of); Kim, Hak Soo; Kim, Hyung Sik; Min, Seung Kee [Gachon Medical School, Incheon (Korea, Republic of)

    2005-09-15

    To evaluate and describe the efficacy and side effects of a percutaneous thrombin injection under ultrasonography guidance for the treatment of iatrogenic pseudo aneurysms Eighteen consecutive iatrogenic pseudo aneurysm cases were treated with a thrombin injection. The thrombin was injected into the pseudo aneurysm cavity using a 22-gauge needle under ultrasonographic guidance. The causes of the pseudo aneurysms are as follows: post coronary angiography (9 cases), percutaneous coronary balloon angioplasty (5 cases), cerebral angiography (1 case), transhepatic chemo embolization (1 case), percutaneous trans femoral arterial stent insertion (1 case) and bone marrow aspiration for a marrow transplant (1 case). Only one case required a secondary thrombin injection due to recurrent flow in the pseudo aneurysm lumen, which was detected at the follow up Doppler ultrasound. Other seventeen cases were successfully treated on the first trial. There were no technical failures or complication related to the procedure. The average amount of thrombin injected was 733 IU. Nine out of 18 treated patients (50%) showed mild reactions to the thrombin including mild fever (4 cases), chilling sensation (3 cases), a chilling sensation with mild dyspnea (1 case), mild chest discomfort (1 case) after the thrombin injection. All these side effects were transient and improved several hours later. All the iatrogenic pseudo aneurysms were treated successfully with an ultrasound-guided percutaneous thrombin injection. There was a high rate of hypersensitivity to the bovine thrombin, which precaution should be taken to prevent more serious side effects

  9. Analytical Methods Development in Support of the Caustic Side Solvent Extraction System

    International Nuclear Information System (INIS)

    Maskarinec, M.P.

    2001-01-01

    The goal of the project reported herein was to develop and apply methods for the analysis of the major components of the solvent system used in the Caustic-Side Solvent Extraction Process (CSSX). These include the calix(4)arene, the modifier, 1-(2,2,3,3- tetrafluoropropoxy)-3-(4-sec-butylphenoxy)-2-propanol and tri-n-octylamine. In addition, it was an objective to develop methods that would allow visualization of other components under process conditions. These analyses would include quantitative laboratory methods for each of the components, quantitative analysis of expected breakdown products (4-see-butylphenol and di-n-octylamine), and qualitative investigations of possible additional breakdown products under a variety of process extremes. These methods would also provide a framework for process analysis should a pilot facility be developed. Two methods were implemented for sample preparation of aqueous phases. The first involves solid-phase extraction and produces quantitative recovery of the solvent components and degradation products from the various aqueous streams. This method can be automated and is suitable for use in radiation shielded facilities. The second is a variation of an established EPA liquid-liquid extraction procedure. This method is also quantitative and results in a final extract amenable to virtually any instrumental analysis. Two HPLC methods were developed for quantitative analysis. The first is a reverse-phase system with variable wavelength W detection. This method is excellent from a quantitative point of view. The second method is a size-exclusion method coupled with dual UV and evaporative light scattering detectors. This method is much faster than the reverse-phase method and allows for qualitative analysis of other components of the waste. For tri-n-octylamine and other degradation products, a GC method was developed and subsequently extended to GUMS. All methods have precision better than 5%. The combination of these methods

  10. Improved fueling and transport barrier formation with pellet injection from different locations on DIII-D

    International Nuclear Information System (INIS)

    Baylor, L.R.; Jernigan, T.C.; Gohil, P.

    2001-01-01

    Pellet injection has been employed on DIII-D from different injection locations to optimize the mass deposition for density profile control and internal transport barrier formation. Transport barriers have been formed deep in the plasma core with central mass deposition from high field side (HFS) injected pellets and in the edge with pellets that trigger L-mode to H-mode transitions. Pellets injected from all locations can trigger the H-mode transition, which depends on the edge density gradient created and not on the radial extent of the pellet deposition. Pellets injected from inside the magnetic axis from the inner wall or vertical port lead to stronger central mass deposition than pellets injected from the low field side (LFS) and thus yield deeper more efficient fueling. (author)

  11. The Classification and Prognosis of Periocular Complications Related to Blindness following Cosmetic Filler Injection.

    Science.gov (United States)

    Myung, Yujin; Yim, Sangjun; Jeong, Jae Hoon; Kim, Baek-Kyu; Heo, Chan-Yeong; Baek, Rong-Min; Pak, Chang-Sik

    2017-07-01

    Common side effects during hyaluronic acid filler injections are typically mild and reversible, but several reports of blindness have received attention. The present study focused on orbital symptoms combined with blindness, aiming to classify affected patients and predict their disease course and prognosis. From September of 2012 to August of 2015, nine patients with vision loss after filler injection were retrospectively reviewed. Ptosis, ophthalmoplegia, and enophthalmos were recorded over a 6-month follow-up, and patients were classified into four types according to periocular symptom manifestation. Two patients were categorized as type I (blindness without ptosis or ophthalmoplegia), two patients as type II (blindness and ptosis without ophthalmoplegia), two patients as type III (blindness and ophthalmoplegia without ptosis), and three patients as type IV (blindness with ptosis and ophthalmoplegia). The present study includes previously unpublished information about orbital symptom manifestations and prognosis combined with blindness caused by retinal artery occlusion after cosmetic filler injection. Therapeutic, V.

  12. Direct injection of gaseous LPG in a two-stroke SI engine for improved performance

    International Nuclear Information System (INIS)

    Pradeep, V.; Bakshi, Shamit; Ramesh, A.

    2015-01-01

    Improvements in a two-stroke, spark-ignition (2S–SI) engine can be realized by curtailing short-circuiting losses effectively through direct injection of the fuel. Liquefied petroleum gas (LPG) is an alternative transportation fuel that is used in several countries. However, limited information is available on LPG fuelled direct injected engines. Hence, there is a need to study these systems as applied to 2S–SI engines in order to bring out their potential benefits. A manifold injected 2S–SI engine is modified for direct injection of LPG, in gaseous form, from the cylinder head. This engine is evaluated for performance, emission and combustion. Evaluation at various throttle positions and constant speed showed that this system can significantly improve the thermal efficiency and lower the hydrocarbon (HC) emissions. Up to 93% reduction in HC emissions and improved combustion rates are observed compared to the conventional manifold injection system with LPG. CO emissions are higher and peak NO emissions are lower with this system due to the presence of richer in–cylinder trapped mixtures and charge stratification. This system can operate with similar injection timings at different throttle positions which make electronic control simpler. It can work with low injection pressures in the range of 4–5 bars. All these advantages are attractive for commercial viability of this engine. - Highlights: • Energy saving, low pressure, direct gaseous LPG injection in engine. • Significant reduction in HC emissions at all operating conditions. • No significant changes in injection timings for different throttle positions.

  13. Cerebral blood flow in the occlusive cerebrovascular disease. 133Xe intravenous injection method

    Energy Technology Data Exchange (ETDEWEB)

    Kuda, Hitoshi; Mukawa, Jiro; Takara, Eiichi; Kinjo, Toshihiko; Ishikawa, Yasunari

    1988-04-01

    From December 1985 to May 1986, cerebral blood flow (CBF) was studied in 11 patients with occlusive cerebrovascular diseases confined by angiography. 133Xe (5mci) intravenous injection method designed by Kuikka and coworkers was applied for the measurement of regional-CBF and mean-CBF, and the calculation was based on the initial slope index. They were composed of 4 patients of the middle cerebral artery occlusion, 2 of the posterior cerebral artery occlusion, 1 of the internal carotid artery occlusion, 2 of the middle cerebral artery stenosis, 1 of the internal carotid artery stenosis, and 1 of the anterior cerebral artery stenosis. The period from the vascular attack to the initial CBF study was 2-29 days(mean 9.2 days). Recovery of mean-CBF was correlated with clinical and neurological improvement, and vice versa. There was no correlation between mean-CBF and neurological severity. CBF study alone is not sufficient to evaluate neuronal conditions in the occlusive disease. Additional other means, such as CT-scan, angiography and etc. should be requested for it. Intravenous 133Xe injection technique has an advantage over intracarotid injection method; less dangerous, especially in ages and capable of simultaneous measurement of bilateral hemisphere. Considering /sup c/ross talk/sup /regional-CBF of a low density area on X-ray CT-scan was equal to the one obtained by intracarotid injection method.

  14. Injection molding of micro pillars on vertical side walls using polyether-ether-ketone (PEEK)

    DEFF Research Database (Denmark)

    Zhang, Yang; Hansen, Hans Nørgaard; Sørensen, Søren

    2016-01-01

    This paper investigates the replication of microstructures on a vertical wall by PEEK injection molding. A 4-cavity insert was used in the injection molding. Pre-fabricated nickel plates with ø 4 μm micro holes on the surface were glued on vertical walls in the cavities. 3 cavities were coated by...

  15. Efficacy of Intravitreal injection of 2-Methoxyestradiol in regression of neovascularization of a retinopathy of prematurity rat model.

    Science.gov (United States)

    Said, Azza Mohamed Ahmed; Zaki, Rania Gamal Eldin; Salah Eldin, Rania A; Nasr, Maha; Azab, Samar Saad; Elzankalony, Yaser Abdelmageuid

    2017-04-04

    Retinopathy of prematurity (ROP) is one of the targets for early detection and treatment to prevent childhood blindness in world health organization programs. The purpose of study was to evaluate the efficacy of intravitreal injection of 2-Methoxyestradiol (2-ME) nanoemulsion in regressing neovascularization of a ROP rat model. A prospective comparative case - control animal study conducted on 56 eyes of 28 healthy new born Sprague Dawley male albino rat. ROP was induced in 21 rats then two concentrations of 2-ME nanoparticles were injected in right eyes of 14 rats (low dose; study group I, high dose; study group II). A blank nanoemulsion was injected in the right eyes of seven rats (control positive group I). No injections performed in contralateral left eyes (control positive group II). Seven rats (14 eyes) were kept in room air (control negative group). On postnatal day 17, eyeballs were enucleated. Histological structure of the retina was examined using Hematoxylin and eosin staining. Vascular endothelial growth factor (VEGF) and glial fibrillary acidic protein (GFAP) expressions were detected by immunohistochemical studies. Intravitreal injection of 2-ME (in the two concentrations) caused marked regression of the new vascular tufts on the vitreal side with normal organization and thickness of the retina especially in study group II, which also show negative VEGF immunoreaction. Positive GFAP expression was detected in the control positive groups and study group (I). Intravitreal injection of 2-Methoxyestradiol nanoemulsion is a promising effective method in reduction of neovascularization of a ROP rat model.

  16. Batch and flow-injection methods for the spectrophotometric determination of olanzapine

    Energy Technology Data Exchange (ETDEWEB)

    Jasinska, A.; Nalewajko, E

    2004-04-22

    An indirect batch spectrophotometric and direct flow-injection (FI) visible spectrophotometric methods have been developed for the determination of the novel anti-psychotic drug olanzapine (OLA). The batch method is based on the oxidation of olanzapine by a known excess of potassium hexacyanoferrate(III) in the presence of the mixture of sulphuric and phosphoric acids (1:1 (v/v)). The absorbance of unreacted oxidant is measured at 425 nm. The absorbance decreases linearly with increasing concentration of the assayed drug. The FI method with detection at 540 nm is based on the direct oxidation of olanzapine one of two oxidants, cerium(IV) sulphate or potassium hexacyanoferrate(III) in acidic medium. The calibration graph were linear over the range of 2.5-40 {mu}g ml{sup -1} in the batch method and 0.05-300 and 0.5-250 {mu}g ml{sup -1} in the FI methods, used cerium (IV) sulphate and potassium hexacyanoferrate (III) respectively. Both FI methods gave similar results in terms of precision and accuracy. The relative standard deviation (R.S.D.), was <1%. The accuracy, obtained from recovery experiments, was 97.9-99.4%. The batch method gave slightly higher R.S.D. values (up to 2.3%) and lower values of accuracy (the recovery was between 96.5 and 96.6%). The methods developed were applied to the determination of olanzapine in a pharmaceutical product.

  17. Accurate, safe, and rapid method of intraoperative tumor identification for totally laparoscopic distal gastrectomy: injection of mixed fluid of sodium hyaluronate and patent blue.

    Science.gov (United States)

    Nakagawa, Masatoshi; Ehara, Kazuhisa; Ueno, Masaki; Tanaka, Tsuyoshi; Kaida, Sachiko; Udagawa, Harushi

    2014-04-01

    In totally laparoscopic distal gastrectomy, determining the resection line with safe proximal margins is often difficult, particularly for tumors located in a relatively upper area. This is because, in contrast to open surgery, identifying lesions by palpating or opening the stomach is essentially impossible. This study introduces a useful method of tumor identification that is accurate, safe, and rapid. On the operation day, after inducing general anesthesia, a mixture of sodium hyaluronate and patent blue is injected into the submucosal layer of the proximal margin. When resecting stomach, all marker spots should be on the resected side. In all cases, the proximal margin is examined histologically by using frozen sections during the operation. From October 2009 to September 2011, a prospective study that evaluated this method was performed. A total of 34 patients who underwent totally laparoscopic distal gastrectomy were enrolled in this study. Approximately 5 min was required to complete the procedure. Proximal margins were negative in all cases, and the mean ± standard deviation length of the proximal margin was 23.5 ± 12.8 mm. No side effects, such as allergy, were encountered. As a method of tumor identification for totally laparoscopic distal gastrectomy, this procedure appears accurate, safe, and rapid.

  18. Predicting Improvement in Writer's Cramp Symptoms following Botulinum Neurotoxin Injection Therapy

    Directory of Open Access Journals (Sweden)

    Mallory Jackman

    2016-09-01

    Full Text Available Introduction: Writer's cramp is a specific focal hand dystonia causing abnormal posturing and tremor in the upper limb. The most popular medical intervention, botulinum neurotoxin type A (BoNT-A therapy, is variably effective for 50–70% of patients. BoNT-A non-responders undergo ineffective treatment and may experience significant side effects. Various assessments have been used to determine response prediction to BoNT-A, but not in the same population of patients. Methods: A comprehensive assessment was employed to measure various symptom aspects. Clinical scales, full upper-limb kinematic measures, self-report, and task performance measures were assessed for nine writer's cramp patients at baseline. Patients received two BoNT-A injections then were classified as responders or non-responders based on a quantified self-report measure. Baseline scores were compared between groups, across all measures, to determine which scores predicted a positive BoNT-A response. Results: Five of nine patients were responders. No kinematic measures were predictably different between groups. Analyses revealed three features that predicted a favorable response and separated the two groups: higher than average cramp severity and cramp frequency, and below average cramp latency. Discussion: Non-kinematic measures appear to be superior in making such predictions. Specifically, measures of cramp severity, frequency, and latency during performance of a specific set of writing and drawing tasks were predictive factors. Since kinematic was not used to determine the injection pattern and the injections were visually guided, it may still be possible to use individual patient kinematics for better outcomes. 

  19. Estimating method for insolation installed to the north side; Kitagawa keishamen nissharyo no suiteiho

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, H; Matsuda, N [Yazaki Corp., Tokyo (Japan)

    1996-10-27

    So as to deal with the trend of installing photovoltaic modules on the north side, a study was made for an expanded application of the insolation data published by Japan Weather Association (which do not include data of insolation on the north side). On the basis of the Association data of the daily amount of insolation on the horizontal plane for the same month and spot, insolation quantity was calculated for every hour for a given azimuth (including the north plane) and angle of inclination by use of a program that had already been developed. With the angle of inclination serving as the parameter, insolation quantities were plotted on the ordinate and azimuths on the abscissa. Although there was difference in absolute value between the Association data and calculated data, supposition was made that the two curves were alike, and this enabled estimation based on the Association data to be expanded to apply to the north side inclined surfaces. It was verified that there was excellent agreement between the Association data curve and calculated data curve in the case of observation for angles not larger than 60{degree} at Kochi, Shizuoka, and Kyoto. Larger angles accompany some error in insolation quantities on inclined surfaces, but this was not so serious as to impede the application of the method. North plane coefficients were determined for the above three spots and insolation quantities on north side inclined surfaces (30{degree} and 60{degree}) were measured. Results of calculations to be carried out for all the 225 spots will be released. 1 ref., 8 figs., 2 tabs.

  20. Flow injection methods for the determination of a-tocopherol with spectrophotometric detection

    International Nuclear Information System (INIS)

    Rishi, L.; Waseem, A.; Yaqoob, M.; Nabi, A.; Jadoon, S.

    2011-01-01

    The present paper describes flow injection procedures for a-tocopherol determination in pharmaceuticals and infant milk powder based on spectrophotometric detection. These two procedures are based on the reduction of iron(III) to iron(II) and of Mo(Vi) to Mo(V) by a-tocopherol and subsequent formation of iron(II)-o-phenanthroline, and phospho molybdenum complexes which were monitored at 510 and 695 nm respectively. Calibration graphs were linear over the concentration range of 0.21-43 mu g/mL for iron(III) and 0.25-10 mu g/mL for Mo(Vi) reduction methods respectively. The limits of detection (3s) of 0.05 and 0.1 mu g/mL with sample throughput of 30 and 50/h respectively were obtained. The relative standard deviations of 1.2- 3.8% (n = 4) was achieved in the concentration range studied. The developed methods were applied to pharmaceuticals and infant milk powders and the results obtained were compared with official method and no significant difference between these methods was observed at 95% confidence level. (author)

  1. Breast EIT using a new projected image reconstruction method with multi-frequency measurements.

    Science.gov (United States)

    Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je

    2012-05-01

    We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography(EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configurational lows us to measure induced voltages only on the front surface of the breast,they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast.

  2. Breast EIT using a new projected image reconstruction method with multi-frequency measurements

    International Nuclear Information System (INIS)

    Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je

    2012-01-01

    We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography (EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configuration allows us to measure induced voltages only on the front surface of the breast, they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast. (paper)

  3. Permanent Magnet Flux Online Estimation Based on Zero-Voltage Vector Injection Method

    DEFF Research Database (Denmark)

    Xie, Ge; Lu, Kaiyuan; Kumar, Dwivedi Sanjeet

    2015-01-01

    In this paper, a simple signal injection method is proposed for sensorless control of PMSM at low speed, which ideally requires one voltage vector only for position estimation. The proposed method is easy to implement resulting in low computation burden. No filters are needed for extracting...

  4. The effect of local injection of the human growth hormone on the mandibular condyle growth in rabbit

    Directory of Open Access Journals (Sweden)

    Masood Feizbakhsh

    2014-01-01

    Full Text Available Background: The aim of this study was to evaluate the effect of local injection of human growth hormone (GH in stimulating cartilage and bone formation in a rabbit model of temporomandibular joint (TMJ. Materials and Methods: In an experimental animal study, 16 male Albino New Zealand white rabbits aged 12 weeks were divided into two groups: In the first group (7 rabbits 2 mg/kg/1 ml human GH and in the control group (9 rabbits 1 ml normal saline was administered locally in both mandibular condyles. Injections were employed under sedation and by single experienced person. Injections were made for 6 times with 3 injections a week in the all test and control samples. Rabbits were sacrified at the 20th day from the beginning of study and TMJs were histologically examined. ANOVA (two-sided with Dunnett post hoc test was used to compare data of bone and cartridge thickness while chi-square test was used to analyze hyperplasia and disk deformity data. P < 0.05 was considered as significant. Results: Cartilage layer thickness was greater in the GH-treated (0.413 ± 0.132 than the control group (0.287 ± 0.098 (P value = 0.02. Although bone thickness and condylar cartilage hyperplasia were greater in the GH-treated group, these differences were not statistically significant (P value = 0.189 and 0.083, respectively. There was no statistically significant difference between two groups regarding the disc deformity (P value = 0.46. Conclusion: Local injection of human GH in the TMJ is able to accelerate growth activity of condylar cartilage in rabbit.

  5. A Coin for the Tsar: The Two Disruptive Sides of Cryptocurrency

    OpenAIRE

    Telley, Chris

    2018-01-01

    Captain Telley warns about the dangers of Russia getting into the cryptocurrency business in "A Coin for the Tsar: The Two Disruptive Sides of Cryptocurrency," written for the Small Wars Journal. As he states, "This paper examines the evolving power of cryptocurrency, describes threat behaviors enabled by the technology, and recommends some ways to counter threat activity in this nascent digital economic environment while preserving the possibilities for healthy innovation." Vladimir Putin...

  6. Apparatus and method for controlling the secondary injection of fuel

    Science.gov (United States)

    Martin, Scott M.; Cai, Weidong; Harris, Jr., Arthur J.

    2013-03-05

    A combustor (28) for a gas turbine engine is provided comprising a primary combustion chamber (30) for combusting a first fuel to form a combustion flow stream (50) and a transition piece (32) located downstream from the primary combustion chamber (30). The transition piece (32) comprises a plurality of injectors (66) located around a circumference of the transition piece (32) for injecting a second fuel into the combustion flow stream (50). The injectors (66) are effective to create a radial temperature profile (74) at an exit (58) of the transition piece (32) having a reduced coefficient of variation relative to a radial temperature profile (64) at an inlet (54) of the transition piece (32). Methods for controlling the temperature profile of a secondary injection are also provided.

  7. Ultra-low emittance beam generation using two-color ionization injection in a CO2 laser-driven plasma accelerator

    International Nuclear Information System (INIS)

    Schroeder, Carl; Benedetti, Carlo; Bulanov, Stepan; Chen, Min; Esarey, Eric; Geddes, Cameron; Vay, J.; Yu, Lule; Leemans, Wim

    2015-01-01

    Ultra-low emittance (tens of nm) beams can be generated in a plasma accelerator using ionization injection of electrons into a wakefield. An all-optical method of beam generation uses two laser pulses of different colors. A long-wavelength drive laser pulse (with a large ponderomotive force and small peak electric field) is used to excite a large wakefield without fully ionizing a gas, and a short-wavelength injection laser pulse (with a small ponderomotive force and large peak electric field), co-propagating and delayed with respect to the pump laser, to ionize a fraction of the remaining bound electrons at a trapped wake phase, generating an electron beam that is accelerated in the wake. The trapping condition, the ionized electron distribution, and the trapped bunch dynamics are discussed. Expressions for the beam transverse emittance, parallel and orthogonal to the ionization laser polarization, are presented. An example is shown using a 10-micron CO 2 laser to drive the wake and a frequency-doubled Ti:Al 2 O 3 laser for ionization injection.

  8. Efficacy and safety of cross-linked hyaluronic acid single injection on osteoarthritis of the knee: a post-marketing phase IV study

    Directory of Open Access Journals (Sweden)

    Bashaireh K

    2015-04-01

    Full Text Available Khaldoon Bashaireh,1 Ziad Naser,2 Khaled Al Hawadya,2 Sorour Sorour,2 Rami Nabeel Al-Khateeb3 1Department of Orthopedics Surgery, King Abdullah University Hospital, Jordan University of Science and Technology, Irbid, Jordan; 2Private Clinic, 3Elaf Medical Supplies Company, Amman, Jordan Purpose: The primary objective of this study was to evaluate the efficacy, safety, and duration of action of viscosupplementation with Crespine® Gel over a 9-month period.Materials and methods: The study was a post-marketing phase IV study. A total of 109 participants with osteoarthritis of the knee (grades 1–4 in the tibio–femoral compartment were recruited in Jordan. Data were collected from each participant during the baseline visit. Each participant received Crespine® Gel injection, and follow-up visits took place at 3 months, 6 months, and 9 months post-injection.Main outcome measure(s: An assessment of participants by phone was conducted at 1 month, 2 months, 4 months, 5 months, 7 months, and 8 months post-injection. Western Ontario and McMaster Universities Arthritis Index questionnaires were completed during each visit. A 72-hour visit questionnaire was used to assess the safety of the injection. Statistical analysis included a two-sided 95% confidence interval for the difference between pain scores across visits, and the percent change from baseline was calculated.Main results: The full analysis included 84 participants who gave their informed consent and finished the necessary baseline and follow-up visits needed to assess efficacy and safety. Peak improvement was noted at 5 months post-injection, when pain and physical performance scores had decreased to 2.60 and 9.90, respectively, and the stiffness score was 0.33. The peak improvement in stiffness was noted at 8 months post-injection, when the stiffness score had decreased to 0.32. Significant improvements were still apparent at 9 months post-injection, when the pain score was 3

  9. Application of EMILAC to pellet injection

    International Nuclear Information System (INIS)

    Iwamura, Yasuhiro; Yamasaki, Takao; Nakamura, Hirone; Hashimoto, Mitsuo; Miya, Kenzo

    1987-01-01

    A new type of electromagnetic accelerator for pellet injection is proposed. Projectile of cylinder shape is accelerated with the repulsive force generated by a combination of two coils, which are different in purpose. And the accelerator is named EMILAC (Electro-Magnetic Inductive Linear Accelerator). In this paper, we investigate the method of applying EMILAC to pellet injection, and calculate the ablation rate of pellet. (author)

  10. Cluster Observations of Particle Injections in the Exterior Cusp

    Science.gov (United States)

    Escoubet, C. P.; Grison, B.; Berchem, J.; Trattner, K. J.; Lavraud, B.; Pitout, F.; Soucek, J.; Richard, R. L.; Laakso, H. E.; Masson, A.; Dunlop, M. W.; Dandouras, I. S.; Reme, H.; Fazakerley, A. N.; Daly, P. W.

    2014-12-01

    The main process that injects solar wind plasma into the polar cusp is now generally accepted to be magnetic reconnection. Depending on the IMF direction, this process takes place equatorward (for IMF southward), poleward (for IMF northward) or on the dusk or dawn sides (for IMF azimuthal) of the cusp. We report a Cluster crossing on 5 January 2002 near the exterior cusp on the southern dusk side. The IMF was mainly azimuthal (IMF-By around -5 nT), the solar wind speed lower than usual around 280 km/s with the density of order 5 cm-3. The four Cluster spacecraft had an elongated configuration near the magnetopause. C4 was the first spacecraft to enter the cusp around 19:52:04 UT, followed by C2 at 19:52:35 UT, C1 at 19:54:24 UT and C3 at 20:13:15 UT. C4 and C1 observed two ion energy dispersions at 20:10 UT and 20:40 UT and C3 at 20:35 UT and 21:15 UT. Using the time of flight technique on the upgoing and downgoing ions, which leads to energy dispersions, we obtain distances of the ion sources between 14 and 20 RE from the spacecraft. Using Tsyganenko model, we find that these sources are located on the dusk flank, past the terminator. The first injection by C3 is seen at approximately the same time as the 2nd injection on C1 but their sources at the magnetopause were separated by more than 7 RE. This would imply that two distinct sources were active at the same time on the dusk flank of the magnetosphere. In addition, a flow reversal was observed at the magnetopause on C4 which would be an indication that reconnection is taking place near the exterior cusp.

  11. Stabilization of Gob-Side Entry with an Artificial Side for Sustaining Mining Work

    Directory of Open Access Journals (Sweden)

    Hong-sheng Wang

    2016-07-01

    Full Text Available A concrete artificial side (AS is introduced to stabilize a gob-side entry (GSE. To evaluate the stability of the AS, a uniaxial compression failure experiment was conducted with large and small-scale specimens. The distribution characteristics of the shear stress were obtained from a numerical simulation. Based on the failure characteristics and the variation of the shear stress, a failure criterion was determined and implemented in the strengthening method for the artificial side. In an experimental test, the distribution pattern of the maximum shear stress showed an X shape, which contributed to the failure shape of the specimen. The shear stress distribution and failure shape are induced by a combination of two sets of shear stresses, which implies that failure of the AS follows the twin shear strength theory. The use of anchor bolts, bolts, and anchor bars enhances the shear strength of the artificial side. When this side is stable, the components can constrain the lateral deformation as well as improve the internal friction angle and cohesion. When the AS is damaged, the components prevent the sliding of broken blocks along the shear failure plane and improve the residual strength of the artificial side. When reinforced with an anchor bar, the AS is still stable even after mining operations for three years.

  12. The activity-integrated method for quality assessment of reduning injection by on-line DPPH-CE-DAD.

    Directory of Open Access Journals (Sweden)

    Yan-xu Chang

    Full Text Available A sensitive on-line DPPH-CE-DAD method was developed and validated for both screening and determining the concentration of seven antioxidants of Reduning injection. The pH and concentrations of buffer solution, SDS, β-CD and organic modifier were studied for the detection of DPPH and seven antioxidants. By on-line mixing DPPH and sample solution, a DPPH-CE method for testing the antioxidant activity of the complex matrix was successfully established and used to screen the antioxidant components of Reduning injection. Then, antioxidant components including caffeic acid, isochlorogenic acid A, isochlorogenic acid B, isochlorogenic acid C, chlorogenic acid, neochlorogenic acid and cryptochlorogenic acid were quantified by the newly established CE-DAD method. Finally, the total antioxidant activity and the multiple active components were selected as markers to evaluate the quality of Reduning injection. The results demonstrated that the on-line DPPH-CE-DAD method was reagent-saving, rapid and feasible for on-line simultaneous determination of total pharmacological activity and contents of multi-components samples. It was also a powerful method for evaluating the quality control and mechanism of action of TCM injection.

  13. Shape, size, velocity and field-aligned currents of dayside plasma injections: a multi-altitude study

    Directory of Open Access Journals (Sweden)

    A. Marchaudon

    2009-03-01

    Full Text Available On 20 February 2005, Cluster in the outer magnetosphere and Double Star-2 (TC-2 at mid-altitude are situated in the vicinity of the northern cusp/mantle, with Cluster moving sunward and TC-2 anti-sunward. Their magnetic footprints come very close together at about 15:28 UT, over the common field-of-view of SuperDARN radars. Thanks to this conjunction, we determine the velocity, the transverse sizes, perpendicular and parallel to this velocity, and the shape of three magnetic flux tubes of magnetosheath plasma injection. The velocity of the structures determined from the Cluster four-spacecraft timing analysis is almost purely antisunward, in contrast with the antisunward and duskward convection velocity inside the flux tubes. The transverse sizes are defined from the Cluster-TC-2 separation perpendicular to the magnetic field, and from the time spent by a Cluster spacecraft in one structure; they are comprised between 0.6 and 2 RE in agreement with previous studies. Finally, using a comparison between the eigenvectors deduced from a variance analysis of the magnetic perturbation at the four Cluster and at TC-2, we show that the upstream side of the injection flux tubes is magnetically well defined, with even a concave front for the third one giving a bean-like shape, whereas the downstream side is far more turbulent. We also realise the first quantitative comparison between field-aligned currents at Cluster calculated with the curlometer technique and with the single-spacecraft method, assuming infinite parallel current sheets and taking into account the velocity of the injection flux tubes. The results agree nicely, confirming the validity of both methods. Finally, we compare the field-aligned current distribution of the three injection flux tubes at the altitudes of Cluster and TC-2. Both profiles are fairly similar, with mainly a pair of opposite field-aligned currents, upward at low-latitude and downward at high-latitude. In terms of

  14. All polymer, injection molded nanoslits, fabricated through two-level UV-LIGA processes

    DEFF Research Database (Denmark)

    Østergaard, Peter Friis; Matteucci, Marco; Marie, Rodolphe

    2012-01-01

    in the micro- and nanoregime is required. To obtain this, injection molding is included in the research process for making several chips (100-1000) with the same layout. The time it takes for the individual chip to be fabricated in this way is much shorter than with conventional cleanroom methods...

  15. Percutaneous intradiscal ozone (O3)-injection: an experimental study in canines

    International Nuclear Information System (INIS)

    Yu Zhijian; He Xiaofeng; Chen Yong; Zeng Qingle; Liu Chihong; Zhao Zhongqing; Lu Yong; Li Yanhao

    2002-01-01

    Objective: To evaluate the influence of ozone on normal nucleus pulpous and the safety of intradiscal ozone-injection for the treatment of herniated lumbar disc. Methods: Ozone was injected into selected lumbar discs (3 ml) and the para-spinal space (7 ml) with 20 G Chiba needle under fluoroscopy in five canines. The ozone concentration was 30 μg/ml and 50 μg/ml respectively. Two discs were selected for each concentration. Total 20 discs were injected. Three of the canines were given one-time ozone-injection and were sacrificed for pathology one week, one month and two months respectively after the procedure, and the other two canines were given two-time ozone-injection and were sacrificed one month and two months respectively after the procedure. The specimens including nucleus pulpous, end-plate, spinal cord, nerve root, and greater psoas muscle were observed macroscopically and microscopically. Results: No serious behavior abnormalities were observed in all animals. The atrophy of nucleus pulpous could be observed one month after ozone-injection due to significant reduction of water and extensive proliferation of collagenous fiber. The influence on the atrophy of nucleus pulpous demonstrated no apparent difference between the selected two concentrations of ozone, but was more apparent with two-time injection than that with one-time injection. The end-plates increased slightly or moderately in thickness in 16 simples and a few of fibers in greater psoas muscle suffered slight atrophy in 5 samples. Conclusion: It is suggested that percutaneous intradiscal ozone-injection is a safe method, and can cause gradual atrophy of nucleus pulpous. This study provides the evidence of the feasibility and value of this procedure's application in clinics

  16. Peritumoural vs intratumoural injections in sentinel node lymphoscintigraphy

    International Nuclear Information System (INIS)

    MacFarlane, L.; Cardaci, G.

    2002-01-01

    Full text: Lymphoscintigraphy has emerged as a method of detecting sentinel lymph nodes (SLN) in breast cancer. Our department started performing these studies in 2001, using 99mTc-Colloidal Antimony Sulphide Injection -dose 30-50MBq. Two methods of injection were used: (a) peritumoural plus subdermal injection - 1.25ml volume (PT), or (b) direct intratumoural injection - 0.2ml volume (IT), both followed by 5-10 min of gentle massage. Patients with a non-palpable mass required a hookwire (HW) inserted at time of injection, and a hotpack was applied in lieu of massage. 125 patients were retrospectively assessed, with 45 PT, 37 IT, 38 HW, and 5 patients had cavity injections. For PT injections, 93% had axillary node drainage (AN), 27% had internal mammary node drainage (IM) and 4% had no drainage to nodes, despite delayed imaging. For IT injections, 84% had AN, 24% had IM, 11% showed no drainage. Of patients having HW, 66% had AN, 34% had IM, 26% no drainage. In our experience, PT injection has a higher yield for SLN localisation than direct IT injection. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Corticosteroid injection for de Quervain's tenosynovitis

    NARCIS (Netherlands)

    Peters-Veluthamaningal, Cyriac; van der Windt, Danielle A. W. M.; Winters, Jan C.; Jong, Betty Meyboom-de

    2009-01-01

    Back ground De Quervain's tenosynovitis is a disorder characterised by pain on the radial (thumb) side of the wrist and functional disability of the hand. It can be treated by corticosteroid injection, splinting and surgery. Objectives To summarise evidence on the efficacy and safety of

  18. 单面与双面信息广告重复效应的实证研究%An Empirical Study on One-sided VS Two-sided Advertising's Repetition Effect

    Institute of Scientific and Technical Information of China (English)

    代祺; 梁樑

    2011-01-01

    By introducing the variable of business ethics perception and integrating Optimal Arousal Theory, Processing Fluency Model, Attribution Theory and Two Factor Theory, the study compares the repetition effects differences between one and two-sided advertisements. Using inter-group experiment design, the results suggest that two-sided advertisements are processed less fluently than one-sided ones, but the percentage of accurate recall and advertisement response are higher than its counterpart. The repetition effects are inverted U shape for one-side advertisements and monotonic increase for two-sided advertisements. Thus, the wearing out effects of two-sided advertisements is delayed. The diversity in perception of business ethics play important role in determining this differences.%通过引入企业道德感知变量,并在整合最优唤醒理论、加工流畅模型、归因理论和两因素理论的基础上,深入剖析了单、双面信息广告重复效应的差异.研究结果表明:双面信息广告比单面信息广告加工更困难,但消费者对其广告正确回忆率更高,广告反应也更积极.单面信息广告的重复效应呈现先增后减的倒U趋势,而双面信息广告的重复效应呈单调递增趋势,疲劳效应延迟出现.消费者对企业道德感知的差异在很大程度上决定了单、双面信息广告重复效应的差异.

  19. Towards spin injection into silicon

    Energy Technology Data Exchange (ETDEWEB)

    Dash, S.P.

    2007-08-15

    Si has been studied for the purpose of spin injection extensively in this thesis. Three different concepts for spin injection into Si have been addressed: (1) spin injection through a ferromagnet-Si Schottky contact, (2) spin injection using MgO tunnel barriers in between the ferromagnet and Si, and (3) spin injection from Mn-doped Si (DMS) as spin aligner. (1) FM-Si Schottky contact for spin injection: To be able to improve the interface qualities one needs to understand the atomic processes involved in the formation of silicide phases. In order to obtain more detailed insight into the formation of such phases the initial stages of growth of Co and Fe were studied in situ by HRBS with monolayer depth resolution.(2) MgO tunnel barrier for spin injection into Si: The fabrication and characterization of ultra-thin crystalline MgO tunnel barriers on Si (100) was presented. (3) Mn doped Si for spin injection: Si-based diluted magnetic semiconductor samples were prepared by doping Si with Mn by two different methods i) by Mn ion implantation and ii) by in-diffusion of Mn atoms (solid state growth). (orig.)

  20. Self-tuning wireless power transmission scheme based on on-line scattering parameters measurement and two-side power matching.

    Science.gov (United States)

    Luo, Yanting; Yang, Yongmin; Chen, Zhongsheng

    2014-04-10

    Sub-resonances often happen in wireless power transmission (WPT) systems using coupled magnetic resonances (CMR) due to environmental changes, coil movements or component degradations, which is a serious challenge for high efficiency power transmission. Thus self-tuning is very significant to keep WPT systems following strongly magnetic resonant conditions in practice. Traditional coupled-mode ways is difficult to solve this problem. In this paper a two-port power wave model is presented, where power matching and the overall systemic power transmission efficiency are firstly defined by scattering (S) parameters. Then we propose a novel self-tuning scheme based on on-line S parameters measurements and two-side power matching. Experimental results testify the feasibility of the proposed method. These findings suggest that the proposed method is much potential to develop strongly self-adaptive WPT systems with CMR.

  1. From Semi- to Full-Two-Dimensional Conjugated Side-Chain Design: A Way toward Comprehensive Solar Energy Absorption

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Pengjie [Department; School; Wang, Huan [Department; Qu, Shiwei [Department; Mo, Daize [Department; Meng, Hong [School; Chen, Wei [Materials; Institute; He, Feng [Department

    2017-12-05

    Two polymers with fully two-dimensional (2D) conjugated side chains, 2D-PTB-Th and 2D-PTB-TTh, were synthesized and characterized through simultaneously integrating the 2D-TT and the 2D-BDT monomers onto the polymer backbone. Resulting from the synergistic effect from the conjugated side chains on both monomers, the two polymers showed remarkably efficient absorption of the sunlight and improved pi-pi intermolecular interactions for efficient charge carrier transport. The optimized bulk heterojunction device based on 2D-PTB-Th and PC71BM shows a higher PCE of 9.13% compared to PTB7-Th with a PCE of 8.26%, which corresponds to an approximately 10% improvement in solar energy conversion. The fully 2D-conjugated side-chain concept reported here developed a new molecular design strategy for polymer materials with enhanced sunlight absorption and efficient solar energy conversion.

  2. Sonographically guided deep plantar fascia injections: where does the injectate go?

    Science.gov (United States)

    Maida, Eugene; Presley, James C; Murthy, Naveen; Pawlina, Wojciech; Smith, Jay

    2013-08-01

    To determine the distribution of sonographically guided deep plantar fascia injections in an unembalmed cadaveric model. A single experienced operator completed 10 sonographically guided deep plantar fascia injections in 10 unembalmed cadaveric specimens (5 right and 5 left) obtained from 6 donors (2 male and 4 female) aged 49 to 95 years (mean, 77.5 years) with a mean body mass index of 23.2 kg/m(2) (range, 18.4-26.3 kg/m(2)). A 12-3-MHz linear array transducer was used to direct a 22-gauge, 38-mm stainless steel needle deep to the plantar fascia at the anterior aspect of the calcaneus using an in-plane, medial-to-lateral approach. In each case, 1.5 mL of 50% diluted colored latex was injected deep to the plantar fascia. After a minimum of 72 hours, study coinvestigators dissected each specimen to assess injectate placement. All 10 injections accurately placed latex adjacent to the deep side of the plantar fascia at the anterior calcaneus. However, the flexor digitorum brevis (FDB) origin from the plantar fascia variably limited direct latex contact with the plantar fascia, and small amounts of latex interdigitated with the FDB origin in 90% (9 of 10). In all 10 specimens, latex also covered the traversing first branch of the lateral plantar nerve (FBLPN, ie, Baxter nerve) between the FDB and quadratus plantae muscles. No latex was found in the plantar fat pad or plantar fascia in any specimen. Sonographically guided deep plantar fascia injections reliably deliver latex deep to the plantar fascia while avoiding intrafascial injection. However, the extent of direct plantar fascia contact is variable due to the intervening FDB. On the contrary, the traversing FBLPN is reliably covered by the injection. Deep plantar fascia injections may have a role in the management of refractory plantar fasciitis, particularly following failed superficial perifascial or intrafascial injections, in cases of preferential deep plantar fascia involvement, or when entrapment

  3. Asynchronous Advanced Encryption Standard Hardware with Random Noise Injection for Improved Side-Channel Attack Resistance

    Directory of Open Access Journals (Sweden)

    Siva Kotipalli

    2014-01-01

    (SCA resistance. These designs are based on a delay-insensitive (DI logic paradigm known as null convention logic (NCL, which supports useful properties for resisting SCAs including dual-rail encoding, clock-free operation, and monotonic transitions. Potential benefits include reduced and more uniform switching activities and reduced signal-to-noise (SNR ratio. A novel method to further augment NCL AES hardware with random voltage scaling technique is also presented for additional security. Thereby, the proposed components leak significantly less side-channel information than conventional clocked approaches. To quantitatively verify such improvements, functional verification and WASSO (weighted average simultaneous switching output analysis have been carried out on both conventional synchronous approach and the proposed NCL based approach using Mentor Graphics ModelSim and Xilinx simulation tools. Hardware implementation has been carried out on both designs exploiting a specified side-channel attack standard evaluation FPGA board, called SASEBO-GII, and the corresponding power waveforms for both designs have been collected. Along with the results of software simulations, we have analyzed the collected waveforms to validate the claims related to benefits of the proposed cryptohardware design approach.

  4. The Incidence of Intravascular Needle Entrance during Inferior Alveolar Nerve Block Injection.

    Science.gov (United States)

    Taghavi Zenouz, Ali; Ebrahimi, Hooman; Mahdipour, Masoumeh; Pourshahidi, Sara; Amini, Parisa; Vatankhah, Mahdi

    2008-01-01

    Dentists administer thousands of local anesthetic injections every day. Injection to a highly vascular area such as pterygomandibular space during an inferior alveolar nerve block has a high risk of intravascular needle entrance. Accidental intravascular injection of local anesthetic agent with vasoconstrictor may result in cardiovascular and central nervous system toxicity, as well as tachycardia and hypertension. There are reports that indicate aspiration is not performed in every injection. The aim of the present study was to assess the incidence of intravascular needle entrance in inferior alveolar nerve block injections. Three experienced oral and maxillofacial surgeons performed 359 inferior alveolar nerve block injections using direct or indirect techniques, and reported the results of aspiration. Aspirable syringes and 27 gauge long needles were used, and the method of aspiration was similar in all cases. Data were analyzed using t-test. 15.3% of inferior alveolar nerve block injections were aspiration positive. Intravascular needle entrance was seen in 14.2% of cases using direct and 23.3% of cases using indirect block injection techniques. Of all injections, 15.8% were intravascular on the right side and 14.8% were intravascular on the left. There were no statistically significant differences between direct or indirect block injection techniques (P = 0.127) and between right and left injection sites (P = 0.778). According to our findings, the incidence of intravascular needle entrance during inferior alveolar nerve block injection was relatively high. It seems that technique and maneuver of injection have no considerable effect in incidence of intravascular needle entrance.

  5. Persistence Probabilities of Two-Sided (Integrated) Sums of Correlated Stationary Gaussian Sequences

    Science.gov (United States)

    Aurzada, Frank; Buck, Micha

    2018-02-01

    We study the persistence probability for some two-sided, discrete-time Gaussian sequences that are discrete-time analogues of fractional Brownian motion and integrated fractional Brownian motion, respectively. Our results extend the corresponding ones in continuous time in Molchan (Commun Math Phys 205(1):97-111, 1999) and Molchan (J Stat Phys 167(6):1546-1554, 2017) to a wide class of discrete-time processes.

  6. Study of process parameters on two phase flow agitated by top blowing lance injection into a bath

    Energy Technology Data Exchange (ETDEWEB)

    Xia Jiliang; Ahokainen, T.; Holappa, L.

    1998-12-31

    Numerical investigation has been carried out for two phase flow in a bath agitated by top blowing lance injection. Eulerian two phase flow model is used. Lance immersion depth, injection gas flow rate, nozzle diameter, and bubble size have been systematically changed to examine their influence on the flow characteristics in the bath. It is found that there appear three typical flow patterns: one-vortex, two-vortex, and three-vortex type, with changing the injection gas flow rate or/and the nozzle diameter at moderate lance immersion depth. Predicted velocities are in a good agreement with Iguchi et al.`s experimental data and the main findings are also consistent with the measurements and observations of Chatterjee and Hsiao and Lehner. (orig.) 24 refs. Computational Fluid Dynamics Technology Programme

  7. A method of encountering the ratio of adjacent sides and its applied study in nuclear engineering survey

    International Nuclear Information System (INIS)

    Wu Jingqin

    1996-01-01

    The cross side or range net survey method is to compute the average error of the measured lengths of sides. With the increment of the side length, the viewing variance increases greatly. Generally the photo-electrical distance survey equipment has a high inside precision, but it is affected by typical weather error so that the outside precision is decreased, and this weather error similar to systematic error greatly decreases the viewing side precision. To solve this problem, theoretical study and field test were carried out for the correlation of ratios among short sides by photo-electrical survey, and the stability degree of the ratios of sides, a new method of ratio encountering of adjacent sides is put forward. Because of the weights of the ration variance σ γ 2 = 2η 2 γ 2 and the angular variance σ β 2 = 2J 2 ρ 2 match each other, so the systematic error can be eliminated completely, and a survey point co-ordinate of high precision can be obtained. It is easy to operate, as it does not require multi-photo-band survey or to operate at the optimal observation time, and is especially suitable to nuclear engineering survey applications. (3 tabs.)

  8. Experiments on injection performance of SMART ECC facility using SWAT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Il; Cho, Seok; Ko, Yung Joo; Min, Kyoung Ho; Shin, Yong Cheol; Kwon, Tae Soon; Yi, Sung Jae; Lee, Won Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    SMART (System-integrated Modular Advanced ReacTor), an advanced integrated PWR is now in the under developing stages by KAERI. Such integral PWR excludes large-size piping of the primary system of conventional PWR and incorporates the SGs into RPV, which means no LBLOCA could occur in SMART. Therefore, the SBLOCA is considered as a major DBA (Design Basis Accident) in SMART and it is mainly analyzed by using TASS/SMR computer code. The TASS/SMR code should be validated using experimental data from both Integral Effect Test and Separate Effect Test facilities. To investigate injection performance of the ECC system, on SET facility, named as SWAT (SMART ECC Water Asymmetric Two-phase choking test facility), has been constructed at KAERI. The SWAT simulates the geometric configurations of the SG-side upper downcomer annulus and ECCSs of those of SMART. It is designed based on the modified linear scaling method with a scaling ratio of 1/5, to preserve the geometrical similarity and minimize gravitational distortion. The purpose of the SWAT tests is to investigate the safety injection performance, such as the ECC bypass in the downcomer and the penetration rate in the core during the SBLOCA, and hence to produce experimental data to validate and the prediction capability of safety analysis codes, TASS/SMR

  9. Comparison of two methods for composite score generation in dry eye syndrome.

    Science.gov (United States)

    See, Craig; Bilonick, Richard A; Feuer, William; Galor, Anat

    2013-09-19

    To compare two methods of composite score generation in dry eye syndrome (DES). Male patients seen in the Miami Veterans Affairs eye clinic with normal eyelid, corneal, and conjunctival anatomy were recruited to participate in the study. Patients filled out the Dry Eye Questionnaire 5 (DEQ5) and underwent measurement of tear film parameters. DES severity scores were generated by independent component analysis (ICA) and latent class analysis (LCA). A total of 247 men were included in the study. Mean age was 69 years (SD 9). Using ICA analysis, osmolarity was found to carry the largest weight, followed by eyelid vascularity and meibomian orifice plugging. Conjunctival injection and tear breakup time (TBUT) carried the lowest weights. Using LCA analysis, TBUT was found to be best at discriminating healthy from diseased eyes, followed closely by Schirmer's test. DEQ5, eyelid vascularity, and conjunctival injection were the poorest at discrimination. The adjusted correlation coefficient between the two generated composite scores was 0.63, indicating that the shared variance was less than 40%. Both ICA and LCA produced composite scores for dry eye severity, with weak to moderate agreement; however, agreement for the relative importance of single diagnostic tests was poor between the two methods.

  10. Rapid contrast infusion of bolus injection for i.v. urography

    International Nuclear Information System (INIS)

    Kaltenborn, H.; Klose, P.; Klose, K.; Schmiedel, E.

    1993-01-01

    The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the use of bolus injections but pressure injections are unnecessary from a diagnostic point view. (orig.) [de

  11. Corticosteroid injection in early treatment of lateral epicondylitis.

    Science.gov (United States)

    Newcomer, K L; Laskowski, E R; Idank, D M; McLean, T J; Egan, K S

    2001-10-01

    To analyze whether a corticosteroid injection in combination with rehabilitation early in the course of lateral epicondylitis (LE) alters the outcome up to 6 months after injection compared with a control injection and rehabilitation. Randomized, controlled, double-blind study. Sports medicine center in a tertiary care center. Subjects with a diagnosis of LE whose symptoms had been present less than 4 weeks were included. Subjects were recruited by word of mouth and through advertising. The 39 subjects who were recruited were 18 to 65 years old. 19 subjects were randomized to receive rehabilitation and a sham injection, and 20 were randomized to receive rehabilitation and a corticosteroid injection. At 4 and 8 weeks, they were reevaluated and their treatment programs were modified, if indicated. Outcome measurements were performed at baseline, 4 weeks, 8 weeks, and 6 months, and included a functional pain questionnaire and a visual analogue pain scale. Painless grip strength on the affected side and maximal grip strength bilaterally were measured at baseline, 4 weeks, and 8 weeks. There were no significant differences in outcome between the two groups with the exception of an improvement in the visual analogue pain scale in the corticosteroid group from 8 weeks to 6 months. Outcome measurements in both groups improved significantly over time; more than 80% of subjects reported improvements from baseline to 6 months for all scales. A corticosteroid injection does not provide a clinically significant improvement in the outcome of LE, and rehabilitation should be the first line of treatment in patients with a short duration of symptoms.

  12. Experimental evaluation of desuperheating and oil cooling process through liquid injection in two-staged ammonia refrigeration systems with screw compressors

    International Nuclear Information System (INIS)

    Zlatanović, Ivan; Rudonja, Nedžad

    2012-01-01

    This paper examines the problem of achieving desuperheating through liquid injection in two-staged refrigeration systems based on screw compressors. The oil cooling process by refrigerant injection is also included. The basic thermodynamic principles of desuperheating and compressor cooling as well as short comparison with traditional method with a thermosyphon system have also been presented. Finally, the collected data referring to a big refrigeration plant are analyzed in the paper. Specific ammonia system concept applied in this refrigeration plant has demonstrated its advantages and disadvantages. - Highlights: ► An experiment was setup during a frozen food factory refrigeration system reconstruction and adaptation. ► Desuperheating and low-stage compressors oil cooling process were investigated. ► Efficiency of compression process and high-stage compressors functioning were examined. ► Evaporation temperature reduction has great influence on the need for injected liquid refrigerant. ► Several cases in which desuperheating and oil cooling process application are justified were determined.

  13. Percutaneous spine injection: considerations for improving treatment

    International Nuclear Information System (INIS)

    Lee, Joon Woo; Kim, Sung Hyun; Lee, In Sook; Choi, Jung Ah; Yoon, Chang Jin; Hwang, Sung Il; Kang, Heung Sik; Choi, Ja Young; Koh, Young Hwan; Hong, Sung Hwan

    2005-01-01

    To discuss the causes of treatment failure in percutaneous spine injections for low back pain or radiculopathy by analyzing patients who have experienced negative treatment effect on their first visit and a positive treatment effect on their second visit. The authors reviewed the cases of 24 patients who visited the pain intervention outpatient department in our hospital due to back pain or radiculopathy. All patients reviewed experienced a negative treatment effect following their first spine injection, but a positive treatment effect following the second injection. The dates of the cases range from June 2003 to May 2004. Two radiologists analyzed the possible causes of the negative treatment effect following the first injection therapies by considering clinical aspects as well as reviewing radiological images. The most common condition was the presence of the change in the level of the second selective nerve root block (n=13). In seven cases, the methods for administering the injections were changed to facet block (n=2), midline epidural block (n=1), selective nerve root block (n=3) and caudal epidural block (n=1). In four cases, there were no changes in the methods for administering the injections nor were there any changes in the level of the selective nerve root block between first and second visit. In those cases, after reviewing spot radiographs performed during injection, we attributed the causes of failure of injection therapy to an inappropriate distribution of drugs. We can improve the effect of percutaneous spine injections for low back pain or radioculopathy by determining the exact level of perineural root block, trying alternative methods, and insuring a good distribution of the injected drugs

  14. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    Science.gov (United States)

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Study on a noninvasive method for rapid screening Human Serum albumin injectables by Raman spectroscopy

    Directory of Open Access Journals (Sweden)

    Yu Zhao

    2017-01-01

    Full Text Available Human serum albumin (HSA injectable product is a severely afflicted area on drug safety due to its high price and restricted supply. Raman spectroscopy performances high specificity on HSA detection and it is even possible to determine HSA injectable products noninvasively. In this study, we developed a noninvasive rapid screening method for of HSA injectable products by using portable Raman spectrometer. Qualitative models were established by using principal component analysis combined with classical least squares (PCA-CLS algorithm, while quantitative model was established by using partial least squares (PLS algorithm. Model transfer in different instruments of both the same and different apparatus modules was further discussed in this paper. A total of 34 HSA injectable samples collected from markets were used for verification. The identification results showed 100% accuracy and the predicted concentrations of those identified as true HSA were consistent with their labeled concentrations. The quantitative results also indicated that model transfer was excellent in the same apparatus modules of Raman spectrometer at all concentration levels, and still good enough in the different apparatus modules although the relative standard deviation (RSD value showed a little increasing trend at low HSA concentration level. In conclusion, the method was proved to be feasible and efficient for screening HSA injections, especially on its screening speed and the consideration of glass containers. Moreover, with inspiring results on the model transfer, the method could be used as a universal screening mean to different Raman instruments.

  16. Imageology and clinical examination: Two sides of the same coin

    Directory of Open Access Journals (Sweden)

    Deepa Das

    2011-01-01

    Full Text Available The continuous and rapid transition of techniques from research lab into clinical practice has been the pattern of development in radiology and imaging, and this has put the concept of clinical imaging into a different perspective. From a passive role of pattern recognition, distinguishing a radiograph from normal to abnormal, the task of a radiologist today has been elevated to reporting a comprehensive clinical imaging assay, giving information at a level profound enough to be useful for scientists working in allied fields. A peep into the literature shows how radiological and clinical examination can be two sides of the same coin.

  17. Selection of peripheral intravenous catheters with 24-gauge side-holes versus those with 22-gauge end-hole for MDCT: A prospective randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Akio, E-mail: a.akahane@gmail.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Kato, Kenichi, E-mail: kkato@iwate-med.ac.jp [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Kamata, Masayoshi, E-mail: kamataaoi@yahoo.co.jp [Iwate Medical University Hospital, 19-1 Uchimaru, Morioka 020-8505 (Japan); Suzuki, Tomohiro, E-mail: suzukitomohiro123@gmail.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Suzuki, Michiko, E-mail: mamimichiko@me.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Nakayama, Manabu, E-mail: gakuymgt@yahoo.co.jp [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Tomabechi, Makiko, E-mail: mtomabechi@mac.com [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan); Nakasato, Tatsuhiko, E-mail: nakasato77@gmail.com [Department of Radiology, Southern Tohoku Research Institute for Neuroscience, 7-115 Yatsuyamada, Koriyama 963-8563 (Japan); Ehara, Shigeru, E-mail: ehara@iwate-med.ac.jp [Department of Radiology, Iwate Medical University School of Medicine, 19-1 Uchimaru, Morioka 020-8505 (Japan)

    2017-02-15

    Highlights: • We compared 24-gauge side-hole and conventional 22-gauge end-hole catheters in MDCT. • The 24-gauge side-hole catheter is noninferior to the 22-gauge end-hole catheter. • The 24-gauge side-hole catheter is safe and facilitates optimal enhancement quality. • The 24-gauge side-hole catheter is suitable for patients with narrow or fragile veins. - Abstract: Purpose: To compare the 24-gauge side-holes catheter and conventional 22-gauge end-hole catheter in terms of safety, injection pressure, and contrast enhancement on multi-detector computed tomography (MDCT). Materials & methods: In a randomized single-center study, 180 patients were randomized to either the 24-gauge side-holes catheter or the 22-gauge end-hole catheter groups. The primary endpoint was safety during intravenous administration of contrast material for MDCT, using a non-inferiority analysis (lower limit 95% CI greater than −10% non-inferiority margin for the group difference). The secondary endpoints were injection pressure and contrast enhancement. Results: A total of 174 patients were analyzed for safety during intravenous contrast material administration for MDCT. The overall extravasation rate was 1.1% (2/174 patients); 1 (1.2%) minor episode occurred in the 24-gauge side-holes catheter group and 1 (1.1%) in the 22-gauge end-hole catheter group (difference: 0.1%, 95% CI: −3.17% to 3.28%, non-inferiority P = 1). The mean maximum pressure was higher with the 24-gauge side-holes catheter than with the 22-gauge end-hole catheter (8.16 ± 0.95 kg/cm{sup 2} vs. 4.79 ± 0.63 kg/cm{sup 2}, P < 0.001). The mean contrast enhancement of the abdominal aorta, celiac artery, superior mesenteric artery, and pancreatic parenchyma in the two groups were not significantly different. Conclusion: In conclusion, our study showed that the 24-gauge side-holes catheter is safe and suitable for delivering iodine with a concentration of 300 mg/mL at a flow-rate of 3 mL/s, and it may contribute to

  18. Neutrophils in Cancer: Two Sides of the Same Coin.

    Science.gov (United States)

    Uribe-Querol, Eileen; Rosales, Carlos

    2015-01-01

    Neutrophils are the most abundant leukocytes in blood and are considered to be the first line of defense during inflammation and infections. In addition, neutrophils are also found infiltrating many types of tumors. Tumor-associated neutrophils (TANs) have relevant roles in malignant disease. Indeed neutrophils may be potent antitumor effector cells. However, increasing clinical evidence shows TANs correlate with poor prognosis. The tumor microenvironment controls neutrophil recruitment and in turn TANs help tumor progression. Hence, TANs can be beneficial or detrimental to the host. It is the purpose of this review to highlight these two sides of the neutrophil coin in cancer and to describe recent studies that provide some light on the mechanisms for neutrophil recruitment to the tumor, for neutrophils supporting tumor progression, and for neutrophil activation to enhance their antitumor functions.

  19. Application of Two-Sided Matching to Internal Labor of the Hellenic Navy

    Science.gov (United States)

    2012-03-01

    Figure 7. The NIMP Algorithm¹³ The first memorable theoretical study of two-sided matching belongs to Milton Friedman and his 1955 article, “The Role...Military Personnel” (Master’s thesis, Naval Postgraduate School, Monterey, 2011). 15. Milton Friedman . “The Role of Government in Education,” in...Research, Cambridge, Massachusetts, June, 2009. Friedman , Milton . “The Role of Government in Education.” In Economics and the Public Interest, edited

  20. Clinical Results of the injection of solcoseryl against disorders of skin and mucosa due to radioactive irradiation

    International Nuclear Information System (INIS)

    Yoshida, Toshio; Yasuhiro, Tsuneaki; Urahashi, Shingo; Tanaka, Hiroshi; Kurihara, Ryutaro

    1974-01-01

    Solcoceryl was injected intravenously in order to protect patients with various types of cancer from suffering the side effects of radiotherapy including dermatitis and mucositis, and in order to treat the side effects. As a result, the efficiency of Solcoseryl was 75% when the drug was given during radiotherapy, and it was 100% when the drug was given after the completion of radiotherapy. Solcoseryl was most effective when it was injected every day or every other day from the early stages of radiotherapy when the side effects were slight, in a total dosage of 20 syringes. These results demonstrated that injections of Solcoseryl are effective in decreasing and treating dermatitis and mucositis due to radiotherapy. (N. Kanao)

  1. Testosterone depot injection in male hypogonadism: a critical appraisal

    Directory of Open Access Journals (Sweden)

    Aksam A Yassin

    2008-01-01

    Full Text Available Aksam A Yassin1, Mohamed Haffejee21Clinic of Urology/Andrology, Segeberger Kliniken, Norderstedt-Hamburg, Germany and Department of Urology, Gulf Medical College School of Medicine, Ajman-UAE 2Urology Division at the University of Witwaterstrand & Johannesburg Hospital, Johannesburg, South AfricaAbstract: Testosterone compounds have been available for almost 70 years, but the pharmaceutical formulations have been less than ideal. Traditionally, injectable testosterone esters have been used for treatment, but they generate supranormal testosterone levels shortly after the 2- to 3-weekly injection interval and then testosterone levels decline very rapidly, becoming subnormal in the days before the next injection. The rapid fluctuations in plasma testosterone are subjectively experienced as disagreeable. Testosterone undecanoate is a new injectable testosterone preparation with a considerably better pharmacokinetic profile. After 2 initial injections with a 6-week interval, the following intervals between two injections are almost always 12-weeks, amounting eventually to a total of 4 injections per year. Plasma testosterone levels with this preparation are nearly always in the range of normal men, so are its metabolic products estradiol and dihydrotestosterone. The “roller coaster” effects of traditional parenteral testosterone injections are not apparent. It reverses the effects of hypogonadism on bone and muscle and metabolic parameters and on sexual functions. Its safety profile is excellent due to the continuous normalcy of plasma testosterone levels. No polycythemia has been observed, and no adverse effects on lipid profiles. Prostate safety parameters are well within reference limits. There was no impairment of uroflow. Testosterone undecanoate is a valuable contribution to the treatment options of androgen deficiency.Keywords: testosterone treatment, testosterone undecanoate, pharmacokinetic profile, clinical efficacy, side effects

  2. A Single-blind, Split-face, Randomized, Pilot Study Comparing the Effects of Intradermal and Intramuscular Injection of Two Commercially Available Botulinum Toxin A Formulas to Reduce Signs of Facial Aging

    Science.gov (United States)

    Sapra, Priya; Sapra, Sheetal; Khanna, Julie; Mraud, Kelli; Bonadonna, Jennifer

    2017-01-01

    Objective: To examine the effectiveness of intradermal botulinum toxin type A injection in improving skin texture and midface lift while reducing pore size and sebum production, as well as investigate the differences in effectiveness between onabotulinumtoxinA and abobotulinumtoxinA using intradermal and intramuscular injection methods. Design: A 16-week, single-blind, split-face, randomized study. Each patient served as their own control, receiving onabotulinumtoxinA and abobotulinumtoxinA randomized to either the left or right side of the face. Patients received intradermal botulinum toxin type A injections at Week 0 and intramuscular botulinum toxin type A injections at Week 2. Participants: Ten women aged 35 to 65 years who exhibited static rhytids in the glabellar and periorbital area. Measurements: The primary endpoint was efficacy of split-face treatment of intradermal and intramuscular onabotulinumtoxinA and abobotulinumtoxinA as assessed by a blinded evaluator using baseline and post-treatment photographs. The secondary endpoints included safety as assessed by adverse events and patient satisfaction measured by questionnaires completed at baseline and post-treatment. Results: Intradermal injection of botulinum toxin type A led to a statistically significant improvement in skin texture (p=0.004) while also resulting in mild midface lift (p=0.024), but did not provide a significant reduction of pore size and sebum production. There was no statistically significant difference between onabotulinumtoxinA and abobotulinumtoxinA when injected intradermally or intramuscularly. Conclusion: Intradermal injection of botulinum toxin type A appears to be a safe and effective therapy that provides an improvement in facial skin texture and midface lift. Registry: clinicaltrials.gov (ID#: NCT02907268). PMID:28367260

  3. Effect of Intravitreal Injection of Bevacizumab on Acute Central Serous Chorioretinopathy Patients Who Visited Feiz Hospital during 2014–2015 Period

    Science.gov (United States)

    Akhlaghi, Mohamad Reza; Nasrollahi, Cobra; Namgar, Seyed Mohamad; Kianersi, Farzan; Dehghani, Ali Reza; Arefpour, Reza

    2017-01-01

    Background: Aim of this clinical trial is the evaluation of the effect of intravitreal injection of bevacizumab on acute central serous chorioretinopathy (CSC). Materials and Methods: In a nonrandomized clinical trial, 36 CSC eyes (with the patients underwent posterior and anterior segment examinations as well as complete eye examination to evaluate the best spectacle-corrected visual acuity (BSCVA). Then, optical coherence tomography was performed to confirm the diagnosis. The patients were divided to the two groups each of 18 subjects, which 18 patients received intravitreal injection of bevacizumab (1.25 mg) and the rest of them did not receive any treatment (control group). The patients were health checked by the end of the 1st and 3rd months. Significance level was considered as P the BSCVA, no significant difference in visual improvement was observed in baseline vision compared to each other (P = 0.481). There was also no significant difference in the vision of intervention and control groups 1 and 3 months after injection (P = 0.379 and P = 0.557). A significant decrement existed in the intervention group compared with the control group in the maximum central macular thickness at 1 month after injection (P = 0.001); however, the difference was not significant when comparing the two groups at baseline and 3 months after injection (P = 0.925 and P = 0.338). Conclusion: In general, according to the results of this study, intravitreal injection of bevacizumab was not effective in improvement of patients with acute CSC, although it had no side effects. PMID:29142888

  4. New method for simultaneous determination of Fe(II) and Fe(III) in water using flow injection technique

    International Nuclear Information System (INIS)

    Kozak, J.; Gutowski, J.; Kozak, M.; Wieczorek, M.; Koscielniak, P.

    2010-01-01

    The method exploits the possibilities of flow injection gradient titration in a system of reversed flow with spectrophotometric detection. In the developed approach a small amount of titrant (EDTA) is injected into a stream of sample containing a mixture of indicators (sulfosalicylic acid and 1,10-phenanthroline). In acid environment sulfosalicylic acid forms a complex with Fe(III), whereas 1,10-phenanthroline forms a complex with Fe(II). Measurements are performed at wavelength λ = 530 nm when radiation is absorbed by both complexes. After injection EDTA replaces sulfosalicylic acid and forms with Fe(III) more stable colourless complex. As a result, a characteristic 'cut off' peak is registered with a width corresponding to the Fe(III) concentration and with a height corresponding to the Fe(II) concentration. Calibration was performed by titration of four two-component standard solutions of the Fe(II)/Fe(III) concentrations established in accordance with 2 2 factorial plan. The method was tested with the use of synthetic samples and then it was applied to the analysis of water samples taken from artesian wells. Under optimized experimental conditions Fe(II) and Fe(III) were determined with precision less than 0.8 and 2.5% (RSD) and accuracy less than 3.2 and 5.1% (relative error) within the concentration ranges of 0.1-3.0 and 0.9-3.5 mg L -1 of both analytes, respectively.

  5. HIV vaccine trial willingness among injection and non-injection drug users in two urban centres, Barcelona and San Francisco.

    Science.gov (United States)

    Etcheverry, M Florencia; Lum, Paula J; Evans, Jennifer L; Sanchez, Emilia; de Lazzari, Elisa; Mendez-Arancibia, Eva; Sierra, Ernesto; Gatell, José M; Page, Kimberly; Joseph, Joan

    2011-02-24

    Being able to recruit high-risk volunteers who are also willing to consider future participation in vaccine trials are critical features of vaccine preparedness studies. We described data from two cohorts of injection- and non-injection drug users in Barcelona, Spain [Red Cross centre] and in San Francisco, USA, [UFO-VAX study] at high risk of HIV/HCV infection to assess behaviour risk exposure and willingness to participate in future preventive HIV vaccine trials. We successfully identified drug-using populations that would be eligible for future HIV vaccine efficacy trials, based on reported levels of risk during screening and high levels of willingness to participate. In both groups, Red Cross and UFO-VAX respectively, HCV infection was highly prevalent at baseline (41% and 34%), HIV baseline seroprevalence was 4.2% and 1.5%, and high levels of willingness were seen (83% and 78%). Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Combination of same-side with opposite-side flavour tagging

    CERN Document Server

    Calvo, M; Musy, M

    2010-01-01

    A considerable number of CP violation measurements require the most possible accurate knowledge of the flavour at production of the reconstructed $B$ meson. The performance of different flavour tagging methods will be measured from control channels. One of the possible tagging methods that can be used is the one known as $Same Side kaon$. In this note we present how to calibrate the response of the tagging algorithms using the data and combine the result with the so called $Opposite Side tagging$. Also trigger and selection effects are briefly discussed.

  7. Two Young Women with Left-sided Pneumothorax Due to Thoracic Endometriosis.

    Science.gov (United States)

    Yukumi, Shungo; Suzuki, Hideaki; Morimoto, Masamitsu; Shigematsu, Hisayuki; Okazaki, Mikio; Abe, Masahiro; Kitazawa, Sohei; Nakamura, Kenji; Sano, Yoshifumi

    Pneumothorax associated with thoracic endometriosis (TE) generally occurs in women around 30 years old and it usually affects the right pleural cavity. We herein report two cases of TE associated with left-sided pneumothorax in young women. The prevalence of TE in younger patients may be underestimated if these cases are treated as spontaneous pneumothorax. Pneumothorax occurring in younger patients has not been reported to show laterality. TE-related or catamenial pneumothorax in young women must therefore represent a different clinical entity from the condition seen in older patients.

  8. Two cases of bradyarrhythmia and hypotension after extradural injections in dogs.

    Science.gov (United States)

    Iff, Isabelle; Moens, Yves

    2008-05-01

    Two healthy obese, seven-year-old, female Rottweilers weighing 40 and 57 kg were submitted for cranial cruciate repair. They were premedicated with intravenous methadone (0.1 mg kg(-1)) and acepromazine (0.01 and 0.02 mg kg(-1)). Anesthesia was induced with propofol (3.6 and 2.5 mg kg(-1)) and maintained with isoflurane in oxygen using a circle breathing system. The dogs were placed in sternal recumbency and epidural injection of lidocaine/bupivacaine or lidocaine/bupivacaine/morphine (0.2 mL/kg, 8 and 11 mL) was carried out over 1.5 and 4 minutes. Epidural pressures were 79 and 72 mmHg at the end of the injections. The first dog's heart rate decreased from 80 to 65 beats minute(-1) with a second degree atrioventricular (AV) block. The arterial pressure decreased from 100 to 50 mmHg. These responded to atropine (0.01 mg kg(-1) IV). The second dog's heart rate decreased from 120 to 60 beats minute(-1) while arterial pressure decreased from 72 to 38 mmHg. No treatment was given and heart rate and arterial blood pressure returned to acceptable ranges. These cases suggest that large increases in epidural pressure may cause significant cardiovascular effects. This may be avoided by using lower volumes and discontinuing injection if significant back pressure is detected.

  9. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.

  10. Dual cloud point extraction coupled with hydrodynamic-electrokinetic two-step injection followed by micellar electrokinetic chromatography for simultaneous determination of trace phenolic estrogens in water samples.

    Science.gov (United States)

    Wen, Yingying; Li, Jinhua; Liu, Junshen; Lu, Wenhui; Ma, Jiping; Chen, Lingxin

    2013-07-01

    A dual cloud point extraction (dCPE) off-line enrichment procedure coupled with a hydrodynamic-electrokinetic two-step injection online enrichment technique was successfully developed for simultaneous preconcentration of trace phenolic estrogens (hexestrol, dienestrol, and diethylstilbestrol) in water samples followed by micellar electrokinetic chromatography (MEKC) analysis. Several parameters affecting the extraction and online injection conditions were optimized. Under optimal dCPE-two-step injection-MEKC conditions, detection limits of 7.9-8.9 ng/mL and good linearity in the range from 0.05 to 5 μg/mL with correlation coefficients R(2) ≥ 0.9990 were achieved. Satisfactory recoveries ranging from 83 to 108% were obtained with lake and tap water spiked at 0.1 and 0.5 μg/mL, respectively, with relative standard deviations (n = 6) of 1.3-3.1%. This method was demonstrated to be convenient, rapid, cost-effective, and environmentally benign, and could be used as an alternative to existing methods for analyzing trace residues of phenolic estrogens in water samples.

  11. Pellet injection and plasma behavior simulation code PEPSI

    International Nuclear Information System (INIS)

    Takase, Haruhiko; Tobita, Kenji; Nishio, Satoshi

    2003-08-01

    Fueling is one of the major issues on design of nuclear fusion reactor and the injection of solid hydrogen pellet to the core plasma is a useful method. On the design of a nuclear fusion reactor, it is necessary to determine requirements on the pellet size, the number of pellets, the injection speed and the injection cycle. PEllet injection and Plasma behavior SImulation code PEPSI has been developed to assess these parameters. PEPSI has two special features: 1) Adopting two numerical pellet models, Parks model and Strauss model, 2) Calculating fusion power and other plasma parameters in combination with a time-dependent one-dimensional transport model. This report describes the numerical models, numerical scheme, sequence of calculation, list of subroutines, list of variables and an example of calculation. (author)

  12. Factors associated with the perception of side-effects relating to the use of contraceptive methods

    Directory of Open Access Journals (Sweden)

    Gerda Erasmus

    1985-09-01

    Full Text Available Limited research has been done in South Africa regarding the incidence of side-effects and perceptions of these among users of contraceptives. Numerous knowledge, attitude and practice (KAP surveys have been conducted by the Human Sciences Research Council (Erasmus 1981a; Erasmus 1981b; Erasmus 1982 ; Groenewald 1978 ; Lótter, Van Tonder 1976; Mostert, Malherbe 1974; Mostert 1974; Strydom 1981; Van der Merwe 1982 and in some of these studies questions concerning side-effects were included to determine reasons for discontinuation of specific contraceptive methods. The literature concerning research on side-effects related to contraceptive use usually pertains either to clinical studies

  13. Direct Observation of Ultrafast Hole Injection from Lead Halide Perovskite by Differential Transient Transmission Spectroscopy.

    Science.gov (United States)

    Ishioka, Kunie; Barker, Bobby G; Yanagida, Masatoshi; Shirai, Yasuhiro; Miyano, Kenjiro

    2017-08-17

    Efficient charge separation at the interfaces of the perovskite with the carrier transport layers is crucial for perovskite solar cells to achieve high power conversion efficiency. We present a systematic experimental study on the hole injection dynamics from MAPbI 3 perovskite to three typical hole transport materials (HTMs). We extract the carrier dynamics directly related to the hole injection by employing a pump light with short absorption depth and comparing the transient transmission signals excited on the two sides of the sample. The differential transmission signals reveal the hole injections to PTAA and PEDOT:PSS to be complete within 1 and 2 ps, respectively, and that to NiO x to exhibit an additional slow process on a 40 ps time scale. The obtained injection dynamics are discussed in comparison with the device performance of the solar cells containing the same MAPbI 3 /HTM interfaces.

  14. Neutrophils in Cancer: Two Sides of the Same Coin

    Directory of Open Access Journals (Sweden)

    Eileen Uribe-Querol

    2015-01-01

    Full Text Available Neutrophils are the most abundant leukocytes in blood and are considered to be the first line of defense during inflammation and infections. In addition, neutrophils are also found infiltrating many types of tumors. Tumor-associated neutrophils (TANs have relevant roles in malignant disease. Indeed neutrophils may be potent antitumor effector cells. However, increasing clinical evidence shows TANs correlate with poor prognosis. The tumor microenvironment controls neutrophil recruitment and in turn TANs help tumor progression. Hence, TANs can be beneficial or detrimental to the host. It is the purpose of this review to highlight these two sides of the neutrophil coin in cancer and to describe recent studies that provide some light on the mechanisms for neutrophil recruitment to the tumor, for neutrophils supporting tumor progression, and for neutrophil activation to enhance their antitumor functions.

  15. Flapping modes of three filaments placed side by side in a free stream

    Science.gov (United States)

    Tian, Fang-Bao; Luo, Haoxiang; Zhu, Luoding; Lu, Xi-Yun

    2010-11-01

    Flexible filaments flapping in a surrounding flow are useful models for understanding the flow-induced vibration and mimicking the schooling behavior of fish. In the present work, the coupled modes of three identical filaments in a side-by- side arrangement are studied using the linear stability analysis and also an immersed boundary--lattice Boltzmann method for low Reynolds numbers (Re on order of 100). The numerical simulations show that the system dynamics exhibits several patterns that depend on the spacing between the filaments. Among these patterns, three can be predicted by the linear analysis and have been reported before. These modes are: (1) the three filaments all flap in phase; (2) the two outer filaments are out of phase while the middle one is stable; (3) the two outer filaments are in phase while the middle one is out of phase. The simulations also identified two additional modes: (1) the outer two filaments are out of phase while the middle one flaps at a frequency reduced by half; (2) the outer two filaments are out of phase while the middle one flaps at a slightly different frequency. In addition to the vibratory modes, the drag force and the flapping amplitude are also computed, and the implication of the result will be discussed.

  16. Comparison Of Simulation Results When Using Two Different Methods For Mold Creation In Moldflow Simulation

    Directory of Open Access Journals (Sweden)

    Kaushikbhai C. Parmar

    2017-04-01

    Full Text Available Simulation gives different results when using different methods for the same simulation. Autodesk Moldflow Simulation software provide two different facilities for creating mold for the simulation of injection molding process. Mold can be created inside the Moldflow or it can be imported as CAD file. The aim of this paper is to study the difference in the simulation results like mold temperature part temperature deflection in different direction time for the simulation and coolant temperature for this two different methods.

  17. Bargaining with Incomplete Information: An Infinite-Horizon Model with Two-Sided Uncertainty

    OpenAIRE

    Peter Cramton

    1984-01-01

    The resolution of any bargaining conflict depends crucially on the relative urgency of the agents to reach agreement and the information each agent has about the others' preferences. This paper explores, within the context of an infinite-horizon bargaining model with two-sided uncertainty, how timing and information affect the rational behaviour of agents when commitment is not possible. Since the bargainers are uncertain about whether trade is desirable, they must communicate some of their p...

  18. Calibration curves for on-line leakage detection using radiotracer injection method

    Directory of Open Access Journals (Sweden)

    Ayoub Khatooni

    2017-11-01

    Full Text Available One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl detectors which were located before and after the considered position, measure emitted gamma from radioactive tracer. After calibration of radiation detectors, the amount of leakage can be calculated based on the count difference of detectors. Also, the effect of material and thickness and diameter of pipe, crystal dimension, types of fluid, activity of tracer and its type (24Na, 82Br, 131I, 99mTc, 113mIn as well as have been investigated on the detectable amount of leakage. According to the results, for example, leakage more than 0.007% in volume of the inlet fluid for iron pipe with outer diameter 4 inch and thickness of 0.5 cm, Petrol as fluid inside pipe, 3 3 inch detector and 24Na with activity of 100 mCi can be detected by this presented method.

  19. Policy and programmatic considerations for introducing a longer-acting injectable contraceptive: perspectives of stakeholders from Kenya and Rwanda

    Science.gov (United States)

    McKenna, Kevin; Arcara, Jennet; Rademacher, Kate H; Mackenzie, Caroline; Ngabo, Fidele; Munyambanza, Emmanuel; Wesson, Jennifer; Tolley, Elizabeth E

    2014-01-01

    ABSTRACT Background: More than 40 million women use injectable contraceptives to prevent pregnancy, and most current or previous injectable users report being satisfied with the method. However, while women may find injectables acceptable, they may not always find them accessible due to stock-outs and difficulties with returning to the clinic for reinjections. FHI 360 is spearheading efforts to develop a longer-acting injectable (LAI) contraceptive that could provide at least 6 months of protection against pregnancy. This article addresses systems-level considerations for the introduction of a new LAI. Methods: We conducted qualitative case studies in Kenya and Rwanda—two countries that have high levels of injectable use but with different service delivery contexts. Between June and September 2012, we conducted in-depth interviews with 27 service providers and 19 policy makers and program implementers focusing on 4 themes: systems-level barriers and facilitators to delivering LAI services; process for introducing an LAI; LAI distribution approaches; and potential LAI characteristics. We also obtained electronic feedback from 28 international family planning opinion leaders. Results: Respondents indicated strong interest in an LAI and thought it would appeal to existing injectable users as well as new family planning clients, both for spacing and for limiting births. Providers appreciated the potential for a lighter workload due to fewer follow-up visits, but they were concerned that fewer visits would also decrease their ability to help women manage side effects. The providers also appreciated the 1-month grace period for follow-up LAI injections; some seemed unaware of the latest international guidance that had increased the grace period from 2 weeks to 4 weeks for the currently available 3-month injectable. The majority of policy makers and program implementers were supportive of letting community health workers provide the method, but many nurses and midwives

  20. The optimal injection technique for the osteoarthritic ankle: A randomized, cross-over trial

    NARCIS (Netherlands)

    Witteveen, Angelique G. H.; Kok, Aimee; Sierevelt, Inger N.; Kerkhoffs, Gino M. M. J.; van Dijk, C. Niek

    2013-01-01

    Background: To optimize the injection technique for the osteoarthritic ankle in order to enhance the effect of intra-articular injections and minimize adverse events. Methods: Randomized cross-over trial. Comparing two injection techniques in patients with symptomatic ankle osteoarthritis. Patients

  1. Soft Roof Failure Mechanism and Supporting Method for Gob-Side Entry Retaining

    Directory of Open Access Journals (Sweden)

    Hongyun Yang

    2015-10-01

    Full Text Available To study the soft roof failure mechanism and the supporting method for a gateway in a gently inclined coal seam with a dip angle of 16° kept for gob-side entry retaining, and through the methodology of field investigation and numerical and analytical modeling, this paper analyzed the stress evolution law of roof strata at the working face end and determined that the sharp horizontal stress unloading phenomenon along the coal wall side did not appear after the working face advanced. Conversely, the horizontal stress along the gob side instantly decreased and the tensile stress produced, and the vertical stress in the central part of the roof had a higher reduction magnitude as well. An in-depth study indicates that the soft roof of the working face end subsided and seriously separated due to the effect of the front abutment pressure and the roof hanging length above the gob line, as well as certain other factors, including the rapid unloading of the lateral stress, tension and shear on the lower roof rock layer and dynamic disturbance. Those influencing factors also led to rapid crack propagation on a large scale and serious fracturing in the soft roof of the working face end. However, in the gob stress stabilized zone, the soft roof in the gob-side entry retaining has a shearing failure along the filling wall inside affected by the overburden pressure, rock bulking pressure, and roof gravity. To maintain the roof integrity, decrease the roof deformation, and enable the control of the working face end soft roof and the stabilization of the gob-side entry retaining roof, this study suggests that the preferred bolt installation angle for the soft roof situation is 70° based on the rock bolt extrusion strengthening theory.

  2. Development of flow injection method for indirect copper determination with amperometric detection in drinking water samples

    Directory of Open Access Journals (Sweden)

    Nikolić-Mandić Snežana

    2012-01-01

    Full Text Available A gas-diffusion flow injection method with amperometric detection for indirect copper determination on a silver electrode is developed. The flow through system is equipped with two injection valves and a gas-diffusion unit. In the first step, a signal of cyanide solution was recorded. In the following step a signal of cyanide in the presence of copper was measured. Interferences (Cd(II, Co(II, Ag(I, Ni(II, Fe(III, Hg(II and Zn(II were investigated and successfully removed. The calibration graph is linear in the range 1-90 μmol dm-3 of copper, correlation coefficient is 0.993, the regression equation is I = (0.0455±0.0015c + (0.4611±0.0671, I is relative signal decrease in μA and c is concentration in μmol dm-3. Relative standard deviation for six consecutive injections of 30 μmol dm-3 copper(II was 1.47 % and for 1 μmol dm-3 copper(II was 3.40 %. The detection limit, calculated as 3 s/m (where s is a standard deviation of nine measurement of a reagent blank and m is the slope of the calibration curve, was 0.32 μmol dm-3, which corresponds to 2.44 ng of copper(II (loop volume was 0.12 cm3. The method enables 60 analyses per hour and it was successfully applied on determination of copper in drinking water samples. [Acknowledgements. The authors acknowledge the grant from the Ministry of Education and Science of the Republic of Serbia, Project number 172051

  3. Efficacy of Botulinum Toxin Injections in the Treatment of Various Types of Facial Region Disorders

    Directory of Open Access Journals (Sweden)

    Arzu Çoban

    2012-12-01

    Full Text Available OBJECTIVE: Local injection of botulinum toxin is a highly effective treatment option for a wide range of movement disorders and there are reliable sources of information on its indications, effects and safety in clinical practice. In this study, we report our experience with botulinum toxin in the treatment of facial region disorders. METHODS: Patients who had been followed in the Botulinum Toxin Outpatient Clinic of the Neurology Department were retrospectively evaluated. Two preparations of botulinum toxin type A (BT-A were used. The efficacy of BT-A injections was rated according to the improvement in symptoms as follows: marked - 75-100% improvement, good - 50-74%, moderate - 25-49%, and insufficient - less than 25% symptom relief. RESULTS: One hundred eighty-two patients (73 male, 109 female with various facial region disorders were included. The efficacy rates for patients who had very good and good improvement were high in the treatment of blepharospasm, hemifacial spasm, facial synkinesis, and Meige syndrome and moderate for oromandibular dystonia and hypersalivation. Ptosis was the most common side effect. CONCLUSION: According to our results, botulinum toxin was very effective treatment for blepharospasm, Meige syndrome, hemifacial spasm and facial synkinesis, whereas it demonstrated good efficacy in oromandibular dystonia and hypersalivation

  4. Vapocoolant Anesthesia for Cosmetic Facial Rejuvenation Injections: A Randomized, Prospective, Split-Face Trial.

    Science.gov (United States)

    Zeiderman, Matthew R; Kelishadi, Shahrooz Sean; Tutela, John Paul; Rao, Arun; Chowdhry, Saeed; Brooks, Ronald M; Wilhelmi, Bradon J

    2018-01-01

    Background: Minimally invasive cosmetic procedures are the most commonly performed aesthetic techniques by plastic surgeons. Patients are interested in a pain-free experience. Surgeons desire patient satisfaction and time-efficient utilization of office staff and resources. Clinical evidence exists for use of vapocoolant technology to reduce pain associated with intravenous cannulation in the pediatric population and in hemodialysis patients. Applying vapocoolant technology to facial rejuvenation is a novel approach to decrease pain associated with neurotoxin or filler injection. Methods: A randomized, prospective study was conducted, testing 15 subjects receiving filler injections and another 15 patients receiving neurotoxin injections using a split-face model. The vapocoolant spray used was composed of a 95:5 ratio of 1,1,1,3,3-pentafluoropropane and 1,1,1,2-tetrafluoroethane. Within each group, individual patients randomly received injection (filler or neurotoxin) alone versus injection (filler or neurotoxin) plus vapocoolant on an equivalent half of his or her face. An independent examiner recorded from each patient on a scale of 1 to 10 perceived pain for injection alone versus injection plus vapocoolant spray. Results were calculated as a percentage change of pain scores experienced after injection for each person between the control (nonvapocoolant) and treatment (vapocoolant) sides of the face. Results: Vapocoolant spray at the time of cosmetic facial injections leads to a 59% decrease in perceived pain score with neurotoxin injections (range, 0%-100% change) and 64% decrease in perceived pain score with filler injections (range, 0%-100% change). These results were statistically significant with P reduces pain associated with facial rejuvenation procedures.

  5. Surgical versus injection treatment for injection-confirmed chronic sacroiliac joint pain

    Science.gov (United States)

    Spiker, William Ryan; Lawrence, Brandon D.; Raich, Annie L.; Skelly, Andrea C.; Brodke, Darrel S.

    2012-01-01

    Study design: Systematic review. Study rationale: Chronic sacroiliac joint pain (CSJP) is a common clinical entity with highly controversial treatment options. A recent systematic review compared surgery with denervation, but the current systematic review compares outcomes of surgical intervention with therapeutic injection for the treatment of CSJP and serves as the next step for evaluating current evidence on the comparative effectiveness of treatments for non-traumatic sacroiliac joint pain. Objective or clinical question: In adult patients with injection-confirmed CSJP, does surgical treatment lead to better outcomes and fewer complications than injection therapy? Methods: A systematic review of the English-language literature was undertaken for articles published between 1970 and June 2012. Electronic databases and reference lists of key articles were searched to identify studies evaluating surgery or injection treatment for injection-confirmed CSJP. Studies involving traumatic onset or non-injection–confirmed CSJP were excluded. Two independent reviewers assessed the level of evidence quality using the grading of recommendations assessment, development and evaluation (GRADE) system, and disagreements were resolved by consensus. Results: We identified twelve articles (seven surgical and five injection treatment) meeting our inclusion criteria. Regardless of the type of treatment, most studies reported over 40% improvement in pain as measured by Visual Analog Scale or Numeric rating Scale score. Regardless of the type of treatment, most studies reported over 20% improvement in functionality. Most complications were reported in the surgical studies. Conclusion: Surgical fusion and therapeutic injections can likely provide pain relief, improve quality of life, and improve work status. The comparative effectiveness of these interventions cannot be evaluated with the current literature. PMID:23526911

  6. Side effects of ambulatory blood pressure monitoring.

    NARCIS (Netherlands)

    Steen, M.S. van der; Lenders, J.W.M.; Thien, Th.

    2005-01-01

    OBJECTIVE: To study the experiences and complaints of patients who underwent 24 h blood pressure monitoring. METHODS: Two groups of hypertensive patients of a tertiary outpatient clinic were asked to fill in a nine-item questionnaire about the side effects of ambulatory blood pressure monitoring

  7. EDF plan for a dispersant injection trial

    International Nuclear Information System (INIS)

    Mercier, Stephane; Corredera, Geraldine; Alves-Vieira, Maria; Mansour, Carine; You, Dominique

    2012-09-01

    In its strategy for SG fouling control, EDF is considering the use of dispersant as a preventive remedy. A trial on Golfech 2 started in May 2012. The dispersant selected for the trial is Polyacrylic Acid (PAA). The main goals of the test are to check and quantify the gain on iron transport to blowdown, to evaluate the possible effects on secondary side chemistry and the operational costs of the injection - reactant, ion exchange resins and filters. The results of the test, if satisfying, will be used to set EDF strategy for dispersant long term use on its fleet. So, one concern about the trial is to make sure that the conclusions of this test will be applicable to a wide range of EDF plants. For that purpose, several criteria have been examined for the choice of the candidate plant such as fouling level, secondary circuit materials (presence or absence of copper alloys,...), SG tube material, thermal power margin, secondary side chemistry (amine used and pH applied). Before starting the trial, EDF had to take into account the international feedback and to adapt it to its specific requirements: the neutralization amine was switched from ETA to morpholine, additional work had been completed to validate the innocuousness of PAA injection for EDF plants... This work especially includes laboratory testing of secondary side corrosion cracking in the presence of PAA and water chemistries used in EdF plants. Moreover, investigation on the thermal stability of PAA and degradation products was completed and further evaluation of environmental impact was performed. A dedicated skid for the injection of PAA was implemented in Golfech Chemicals injection room. The installation and the process were notably designed to take into account the high viscosity of the commercial product, and the need to proceed to a good rinsing of the pipes without increasing the discharged effluents. The first available data from Golfech 2 trial are also provided and discussed. (authors)

  8. Pentadiagonal alternating-direction-implicit finite-difference time-domain method for two-dimensional Schrödinger equation

    Science.gov (United States)

    Tay, Wei Choon; Tan, Eng Leong

    2014-07-01

    In this paper, we have proposed a pentadiagonal alternating-direction-implicit (Penta-ADI) finite-difference time-domain (FDTD) method for the two-dimensional Schrödinger equation. Through the separation of complex wave function into real and imaginary parts, a pentadiagonal system of equations for the ADI method is obtained, which results in our Penta-ADI method. The Penta-ADI method is further simplified into pentadiagonal fundamental ADI (Penta-FADI) method, which has matrix-operator-free right-hand-sides (RHS), leading to the simplest and most concise update equations. As the Penta-FADI method involves five stencils in the left-hand-sides (LHS) of the pentadiagonal update equations, special treatments that are required for the implementation of the Dirichlet's boundary conditions will be discussed. Using the Penta-FADI method, a significantly higher efficiency gain can be achieved over the conventional Tri-ADI method, which involves a tridiagonal system of equations.

  9. Anesthetic efficacy of a repeated intraosseous injection following a primary intraosseous injection.

    Science.gov (United States)

    Jensen, Joanne; Nusstein, John; Drum, Melissa; Reader, Al; Beck, Mike

    2008-02-01

    The purpose of this prospective, randomized, single-blinded study was to determine the anesthetic efficacy of a repeated intraosseous injection given 30 minutes after a primary intraosseous injection. Using a crossover design, 55 subjects randomly received a primary X-tip intraosseous injection (Dentsply Inc, York, PA) of 1.4 mL of 2% lidocaine with epinephrine (using the Wand; Milestone Scientific, Deerfield, IL) and a repeated intraosseous or mock injection at 30 minutes in two appointments. The first molar and adjacent teeth were pulp tested every 2 minutes for a total of 120 minutes. Success was defined as obtaining two consecutive 80 readings with the electric pulp tester. Success of the initial intraosseous injection was 100% for the first molar. The repeated intraosseous injection mimicked the initial intraosseous injection in terms of pulpal anesthesia and statistically provided another 15 minutes of pulpal anesthesia. In conclusion, using the methodology presented, repeating the intraosseous injection 30 minutes after an initial intraosseous injection will provide an additional 15 minutes of pulpal anesthesia.

  10. Comparison of two different molecular weight intra-articular injections of hyaluronic acid for the treatment of knee osteoarthritis

    Science.gov (United States)

    Gigis, I; Fotiadis, E; Nenopoulos, A; Tsitas, K; Hatzokos, I

    2016-01-01

    Background: Knee osteoarthritis (OA) is an incurable joint disorder, representing a major public health issue. Among options for symptom control, viscosupplementation with hyaluronic acid (HA) had established usefulness in pain and function improvement of the knee. However, it is not clear which form of HA yields better results. Material and Methods:We compared two HA preparations with high (HMW) or low molecular weight (LMW) in terms of pain control and function improvement using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the visual analog scale (VAS) score in patients with knee OA. During 2013, 80 patients were enrolled in this prospective, double-blind, randomized study. Each patient received a weekly injection of either preparation with a total of five injections for the LMW group and three for the HMW group. They were evaluated at baseline, five weeks, three months and one year after treatment. Results: In both groups, HA treatment resulted in significant improvement in pain and function that begun immediately after treatment and lasted for one year. However when compared with each other, HMW and LMW groups were comparable in mean WOMAC, and VAS score at each time point. Neither preparation can interrupt disease progression as radiological findings remained constant during follow-up. Conclusions: Intra-articular injections using HMW or LMW HA can improve stiffness, joint function and pain in patients suffering from knee OA. However, no clear benefit seems to exist between the two preparations and neither can slow disease progression. Hippokratia 2016, 20(1): 26-31 PMID:27895439

  11. Effects of Two Different Anesthetic Solutions on Injection Pain, Efficacy, and Duration of Soft-Tissue Anesthesia with Inferior Alveolar Nerve Block for Primary Molars.

    Science.gov (United States)

    Elbay, Ülkü Şermet; Elbay, Mesut; Kaya, Emine; Yıldırım, Sinem

    The purpose of the study was to compare the efficacy, injection pain, duration of soft tissue anesthesia, and postoperative complications of two different anesthetics (2% lidocaine with 1:80,000 epinephrine and 3% plain mepivacaine) in pediatric patients in inferior alveolar nerve block (IANB) administered by a computer-controlled delivery system (CCDS). The study was conducted as a randomized, controlled-crossover, double-blind clinical trial with 60 children requiring bilateral pulpotomy or extraction of primary mandibular molars. A CCDS was used to deliver 3% mepivacaine to 1 primary tooth and 2% lidocaine to the contralateral tooth with an IANB technique. Severity of pain and efficacy of anesthesia were evaluated using the Face, Legs, Activity, Cry, Consolability Scale, and comfort and side effects were assessed using a questionnaire. Data were analyzed using the Mann-Whitney U, Wilcoxon t, and Fisher exact tests. Patients receiving 2% lidocaine experienced significantly less pain during injection than those receiving 3% mepivacaine, and no significant differences were found in the pain scores during treatments or in postoperative complications between the two anesthetics. The mean durations of anesthesia for 3% mepivacaine and 2% lidocaine were 139.68 minutes and 149.10 minutes, respectively. Plain mepivacaine and 2% lidocaine were similarly effective in pulpotomy and the extraction of primary mandibular molars. Although the use of 3% mepivacaine provided a shorter duration of anesthesia than 2% lidocaine, both solutions showed similar results in terms of postoperative complications.

  12. Laparoscopic side-to-side pancreaticojejunostomy for chronic pancreatitis in children

    Directory of Open Access Journals (Sweden)

    Kyoichi Deie

    2016-01-01

    Full Text Available Surgical pancreatic duct (PD drainage for chronic pancreatitis in children is relatively rare. It is indicated in cases of recurrent pancreatitis and PD dilatation that have not responded to medical therapy and therapeutic endoscopy. We performed laparoscopic side-to-side pancreaticojejunostomy for two paediatric patients with chronic pancreatitis. The main PD was opened easily by electrocautery after locating the dilated PD by intraoperative ultrasonography. The dilated PD was split longitudinally from the pancreatic tail to the pancreatic head by laparoscopic coagulation shears or electrocautery after pancreatography. A laparoscopic side-to-side pancreaticojejunostomy was performed by a one-layered technique using continuous 4-0 polydioxanone (PDS sutures from the pancreatic tail to the pancreatic head. There were no intraoperative or postoperative complications or recurrences. This procedure has cosmetic advantages compared with open surgery for chronic pancreatitis. Laparoscopic side-to-side pancreaticojejunostomy in children is feasible and effective for the treatment of chronic pancreatitis.

  13. Prevalence of hepatitis C virus and HIV infection among injection drug users in two Mexican cities bordering the U.S

    OpenAIRE

    White, Emily Faye; Garfein, Richard S.; Brouwer, Kimberly C; Lozada, Remedios; Ramos, Rebeca; Firestone-Cruz, Michelle; Pérez, Saida G; Magis-Rodríguez, Carlos; Conde-Glez, Carlos J; Strathdee, Steffanie A

    2007-01-01

    OBJECTIVE: To estimate the prevalence of the hepatitis C virus (HCV) and HIV infection and associated risk behaviors among injection drug users (IDUs) in two northern Mexican cities. MATERIAL AND METHODS: Between February and April 2005, IDUs were recruited in Tijuana (N=222) and Ciudad Juarez (N=206) using respondent-driven sampling (RDS), a chain referral sampling approach. Interviewer-administered questionnaires assessed drug-using behaviors during the prior six months. Venous blood was co...

  14. A method of calorimetric detection of two-dimensional atomic hydrogen using an induced two-body exchange recombination

    International Nuclear Information System (INIS)

    Frolov, A.V.; Safonov, A.I.; Vasilyev, S.A.; Lukashevich, I.I.

    1994-01-01

    We propose a novel method to detect hydrogen atoms in the pure hyperfine state b at the small dense spot of the sample cell surface by injecting in pulses small controlled amounts of atoms in the reactive mixed state a into the cell volume. The total recombination rate inferred from a carbon bolometer overheating will display pronounced peaks due to two-body ab recombination. The relaxation rate of these peaks to the original value of the bolometer signal will be proportional to b-atoms' density at the spot. This method can be applied to measure the surface density of polarized H in the experiments with the field compression and with the cold spot as well. 14 refs., 4 figs

  15. Modeling and investigation of refrigeration system performance with two-phase fluid injection in a scroll compressor

    Science.gov (United States)

    Gu, Rui

    Vapor compression cycles are widely used in heating, refrigerating and air-conditioning. A slight performance improvement in the components of a vapor compression cycle, such as the compressor, can play a significant role in saving energy use. However, the complexity and cost of these improvements can block their application in the market. Modifying the conventional cycle configuration can offer a less complex and less costly alternative approach. Economizing is a common modification for improving the performance of the refrigeration cycle, resulting in decreasing the work required to compress the gas per unit mass. Traditionally, economizing requires multi-stage compressors, the cost of which has restrained the scope for practical implementation. Compressors with injection ports, which can be used to inject economized refrigerant during the compression process, introduce new possibilities for economization with less cost. This work focuses on computationally investigating a refrigeration system performance with two-phase fluid injection, developing a better understanding of the impact of injected refrigerant quality on refrigeration system performance as well as evaluating the potential COP improvement that injection provides based on refrigeration system performance provided by Copeland.

  16. An exploration of fluoroscopically guided spinal steroid injections in patients with non-specific exercise-related lower-limb pain

    Directory of Open Access Journals (Sweden)

    Leon Neve

    2010-09-01

    Full Text Available Leon Neve1, John Orchard2, Nathan Gibbs3, Willem van Mechelen4, Evert Verhagen4, Ken Sesel5, Ian Burgess6, Brett Hines61VU University, Amsterdam, The Netherlands; 2School of Public Health, University of Sydney, Sydney, NSW, Australia; 3South Sydney Sports Medicine, Sydney, NSW, Australia; 4EMGO, VU University, Amsterdam, The Netherlands; 5Sydney X-ray Centre, Sydney, NSW, Australia; 6Mater Imaging, Sydney, NSW, AustraliaBackground: Fluoroscopically guided lumbar cortisone injections have been proven useful in cases of lower-limb pain caused by lumbar disc prolapse (with evidence levels ll-1/ll-2. These injections are also sometimes used clinically in sports medicine for patients with non-specific exercise-related lower-limb pain, where no prolapse or other obvious cause of nerve-impingement is diagnosed via magnetic resonance imaging (MRI or computed tomography (CT, even though this treatment scenario has not been adequately studied for this last diagnosis.Objectives: To explore whether fluoroscopically guided transforaminal lumbar cortisone injections may be a valid treatment method for non-specific exercise-related lower-limb pain.Study design: Retrospective case series.Methods: Patients were selected from databases at two sports clinics and divided into two groups: Group D, with back-related lower-limb pain and disc prolapse proven on CT or MR; and Group N, with non-specific exercise-related lower-limb pain. Patients were sent a questionnaire regarding: symptoms, improvement, effect of injections, satisfaction, side effects and other used treatments. Outcomes were compared between Group D and N.Results: 153 patients were eligible for the study (Group D: 93/Group N: 60. Eventually 110 patients responded (Group D: 67/Group N: 43. Twelve percent of Group D and 14% of Group N indicated that the injections had fully cured their symptoms. Altogether, 27% of Group D and 24% of Group N were certain the injections had improved their symptoms in the

  17. Percutaneous injection of hemostatic agents for severe blunt hepatic trauma: an experimental study

    International Nuclear Information System (INIS)

    Tang, Jie; Lv, Faqin; Li, Wenxiu; Zhang, Huiqin; Luo, Yukun; An, Lichun; Li, Tanshi

    2008-01-01

    This study was designed to evaluate whether percutaneous injection of hemostatic agents under the guidance of contrast-enhanced ultrasound (CEUS) can stop hemorrhage from severe hepatic trauma. Eighteen dogs were impacted by a miniature impactor to create blunt hepatic trauma. Fourteen with appropriate liver lesions were divided into two groups: the treatment group (n=7) and the control group (n=7). In the treatment group, hemocoagulase atrox and α-cyanoacrylate were respectively injected into the injury sites and transected micro-vessels under the guidance of CEUS. In the control group, normal saline was injected into the injury sites. CEUS and CT were performed at 3, 7, 14, and 21 days after the focal injection. Surviving animals were killed on the 21st day for pathologic examination. All animals of the treatment group survived. Three dogs of the control group died in the first 24 h. In the treatment group, CEUS and CT demonstrated that hepatic lesions became smaller gradually from the 3rd to the 21st day after injection. The focal injection of hemostatic agents under the guidance of CEUS can stop hemorrhage from hepatic trauma of grade III∝IV or IV. During the period of 3 weeks, no side effect was found. (orig.)

  18. Percutaneous injection of hemostatic agents for severe blunt hepatic trauma: an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Jie; Lv, Faqin; Li, Wenxiu; Zhang, Huiqin; Luo, Yukun; An, Lichun [Chinese People' s Liberation Army General Hospital, Department of Ultrasound, Beijing (China); Li, Tanshi [Chinese People' s Liberation Army General Hospital, Department of Intensive Care Unit, Beijing (China)

    2008-12-15

    This study was designed to evaluate whether percutaneous injection of hemostatic agents under the guidance of contrast-enhanced ultrasound (CEUS) can stop hemorrhage from severe hepatic trauma. Eighteen dogs were impacted by a miniature impactor to create blunt hepatic trauma. Fourteen with appropriate liver lesions were divided into two groups: the treatment group (n=7) and the control group (n=7). In the treatment group, hemocoagulase atrox and {alpha}-cyanoacrylate were respectively injected into the injury sites and transected micro-vessels under the guidance of CEUS. In the control group, normal saline was injected into the injury sites. CEUS and CT were performed at 3, 7, 14, and 21 days after the focal injection. Surviving animals were killed on the 21st day for pathologic examination. All animals of the treatment group survived. Three dogs of the control group died in the first 24 h. In the treatment group, CEUS and CT demonstrated that hepatic lesions became smaller gradually from the 3rd to the 21st day after injection. The focal injection of hemostatic agents under the guidance of CEUS can stop hemorrhage from hepatic trauma of grade III{proportional_to}IV or IV. During the period of 3 weeks, no side effect was found. (orig.)

  19. Two sides of the same coin? The (techno)epistemic cultures of systems and synthetic biology.

    Science.gov (United States)

    Kastenhofer, Karen

    2013-06-01

    Systems and synthetic biology both emerged around the turn of this century as labels for new research approaches. Although their disciplinary status as well as their relation to each other is rarely discussed in depth, now and again the idea is invoked that both approaches represent 'two sides of the same coin'. The following paper focuses on this general notion and compares it with empirical findings concerning the epistemic cultures prevalent in the two contexts. Drawing on interviews with researchers from both fields, on participatory observation in conferences and courses and on documentary analysis, this paper delineates differences and similarities, incompatibilities and blurred boundaries. By reconstructing systems and synthetic biology's epistemic cultures, this paper argues that they represent two 'communities of vision', encompassing heterogeneous practices. Understanding the relation of the respective visions of understanding nature and engineering life is seen as indispensible for the characterisation of (techno)science in more general terms. Depending on the conceptualisation of understanding and construction (or: science and engineering), related practices such as in silico modelling for enhancing understanding or enabling engineering can either be seen as incommensurable or 'two sides of one coin'. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Gas-assisted injection moulding: adding two components and moveable inserts

    NARCIS (Netherlands)

    Neerincx, P.E.; Meijer, H.E.H.

    2009-01-01

    Gas assisted injection moulding (GAIM) is a technique that is successfully used for compensating shrinkage during injection moulding of thick walled but still accurate products with low levels of internal stresses and frozen-in orientation. In this study the authors apply GAIM in moulding 28 mm

  1. Effect of Intravitreal Injection of Bevacizumab on Acute Central Serous Chorioretinopathy Patients who Visited Feiz Hospital during 2014–2015 Period

    Directory of Open Access Journals (Sweden)

    Mohamad Reza Akhlaghi

    2017-01-01

    Full Text Available Background: Aim of this clinical trial is the evaluation of the effect of intravitreal injection of bevacizumab on acute central serous chorioretinopathy (CSC. Materials and Methods: In a nonrandomized clinical trial, 36 CSC eyes (with <1-month disease history were examined. Initially, all the patients underwent posterior and anterior segment examinations as well as complete eye examination to evaluate the best spectacle-corrected visual acuity (BSCVA. Then, optical coherence tomography was performed to confirm the diagnosis. The patients were divided to the two groups each of 18 subjects, which 18 patients received intravitreal injection of bevacizumab (1.25 mg and the rest of them did not receive any treatment (control group. The patients were health checked by the end of the 1st and 3rd months. Significance level was considered as P < 0.05. Results: In the BSCVA, no significant difference in visual improvement was observed in baseline vision compared to each other (P = 0.481. There was also no significant difference in the vision of intervention and control groups 1 and 3 months after injection (P = 0.379 and P = 0.557. A significant decrement existed in the intervention group compared with the control group in the maximum central macular thickness at 1 month after injection (P = 0.001; however, the difference was not significant when comparing the two groups at baseline and 3 months after injection (P = 0.925 and P = 0.338. Conclusion: In general, according to the results of this study, intravitreal injection of bevacizumab was not effective in improvement of patients with acute CSC, although it had no side effects.

  2. Possibilities of nontoxic autonomous thyroid nodules treatment by percutaneous ethanol injection

    Directory of Open Access Journals (Sweden)

    Anđelković Zoran

    2011-01-01

    Full Text Available Background/Aim. According to the current principles, autonomous functional thyroid nodules are treated by surgery or by radioiodin therapy. Ultrasound guided percutaneous ethanol injection into solid tumors of the soft tissues was a starting point in attempts to treat the thyroid nodules by the same method. The aim of the study was to assess the efficiency of percutaneous injection in treating solitary, nontoxic, autonomous thyroid nodules of up to 15 mL volume. Methods. In 25 patients with solitary nontoxic autonomous thyroid nodules diagnosed by tehnetium-99m scanning as an intensive area having a complete supremacy in the paranodal tissue, an ultrasound guided percutaneous ethanol injection was applied. The procedure was carried out repeatedly once a week until the reduction in nodule size to 50% of the initial size was achieved. Results. An average size of the nodule before curing was 9.68 ± 5.01 mL. An average quantity of the injected ethanol was 9.52 ± 5.08 mL, ie 1.06 ± 0.48 mL/mg of the tissue. The regression of the nodule size in the successfully (Δvol% u = - 57.09 ± 13.75%, p < 0.001 and partly successfully cured (Δvol du = -48.45 ± 14.35%, p < 0.05 was statistically significant compared to the size before the treatment. After ceasing ethanol injection, 18 months later, a further size regression (Δvol% = -79.20 ± 9.89% compared to the initial one (p < 0.001 was noticed. Soon, after the procedure was finished, a statistically significant concentration increase of Thyroid Stimulating Hormone (TSH was noticed compared to the initial values (0.18 ± 0.16 vs 0.34 ± 0.31 mU/L, p < 0.01. According to the given criteria, in two female patients satisfactory results were not achieved, but, a year later, in one of them the nodule was not seen by repeated scintigram. The number and frequency of side effects were insignificant. Conclusion. Repeated percutaneous ethanol injections into nontoxic solitary autonomous thyroid nodules result in

  3. Reductions of PAH and Soot by Center Air Injection

    Directory of Open Access Journals (Sweden)

    Kazuhiro Yamamoto

    2014-07-01

    Full Text Available In this study, to reduce the amount of pollutant PAH and soot in the flame, we examined the burner system equipped with a center air injection. For this purpose, by using PAH-LIF and soot LII, we evaluated relative PAH and soot amounts in both the triple port burner and the conventional co-axial burner (double port burner to discuss effects of center air injection on the formation of PAH and soot. The fuel was propane. In the triple port burner, two different blue flames are observed near the burner rim, followed by bright luminous flames with soot. The flame length is longer when the fuel flow velocity is increased. On the other hand, the flame length is shorter with an increase in internal air flow velocity. As for PAH and soot, these amounts of the triple port burner are much smaller than those of the double port burner. For the triple port burner, due to the center air injection, the fuel consumption occurs in both inner and outer flames. On the other hand, for the double port burner, the oxygen is supplied from one side air, and as a result, the fuel consumption rate is relatively lower. Hence, by the center air injection, the fuel consumption is largely accelerated, resulting in the reduction of PAH and soot.

  4. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Energy Technology Data Exchange (ETDEWEB)

    Aalseth, C.E.; et al.

    2017-07-25

    Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\\gt3\\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $\

  5. Usefulness of an injectable anaesthetic protocol for semen collection through urethral catheterisation in domestic cats.

    Science.gov (United States)

    Pisu, Maria Carmela; Ponzio, Patrizia; Rovella, Chiara; Baravalle, Michela; Veronesi, Maria Cristina

    2017-10-01

    Objectives Although less often requested in comparison with dogs, the collection of semen in cats can be necessary for artificial insemination, for semen evaluation in tom cats used for breeding and for semen storage. Urethral catheterisation after pharmacological induction with medetomidine has proved to be useful for the collection of semen in domestic cats. However, most of the previously used protocols require the administration of high doses of medetomidine that can increase the risk of side effects, especially on the cardiovascular system. In routine clinical practice, one safe and useful injectable anaesthetic protocol for short-term clinical investigations or surgery in cats involves premedication with low intramuscular doses of dexmedetomidine with methadone, followed by intravenous propofol bolus injection. We aimed to assess the usefulness of this injectable anaesthetic protocol for semen collection, via urethral catheterisation, in domestic cats. Methods The study was performed on 38 purebred, adult cats, during the breeding season, and semen was collected via urethral catheterisation using an injectable anaesthesia protocol with methadone (0.2 mg/kg) and dexmedetomidine (5 µg/kg) premedication, followed by induction with propofol. Results The anaesthetic protocol used in the present study allowed the collection of large-volume semen samples, characterised by good parameters and without side effects. Conclusions and relevance The results from the present study suggest that the injectable anaesthetic protocol using methadone and dexmedetomidine premedication, followed by induction with propofol, could be suitable and safe for the collection of a good-quality semen sample, via urethral catheterisation, in domestic cats. It can therefore be used as an alternative to previous medetomidine-based sedation protocols.

  6. Intradermal Alcian-Blue Injection Method to Trace Acupuncture Meridians

    Directory of Open Access Journals (Sweden)

    Baeckkyoung Sung

    2008-06-01

    Full Text Available Objective : In this article, we report on the intradermal Alcian blue staining method for tracing the meridians of acupuncture. Methods : 1% Alcian blue solution was injected into acupoints by using a 0.5mL insulin syringe with a 31-gauge needle, then the skin was incised and was observed under a stereoscopic microscope. The specimens were examined by using immunohistochemical methods and were observed under a confocal laser scanning microscope. Results : A threadlike structure, which was visualized with Alcian blue, existed in dermis layer and proceeded to hypodermis. In this structure, characteristic alignments of rod- shaped nuclei and 1-2μm sized DNA granules were observed. Furthermore, abundant blood capillary plexuses, peripheral nerve endings, and a corpusclelike structure(about 300μm in diameter were visualized in the skin tissues of acupoints. Conclusion : It was concluded that the specific threadlike and corpuscle-like structures corresponded to superficial Bonghan duct and corpuscle, respectively.

  7. OCDMA PON supporting ONU inter-networking based on gain-switched Fabry-Pérot lasers with external dual-wavelength injection.

    Science.gov (United States)

    Liu, Jie; Zeng, Duoduo; Guo, Changjian; Xu, Lei; He, Sailing

    2010-10-25

    We propose and demonstrate an OCDMA-PON scheme with optical network unit (ONU) internetworking capability, which utilizes low-cost gain-switched Fabry-Pérot (GS-FP) lasers with external dual-wavelength injection as the pulse sources on the ONU side. The injection-generated optical pulses in two wavelengths from the same GS-FP laser are used separately for the PON uplink transmission and ONU internetworking. Experimental results based on a two-user OCDMA system confirm the feasibility of the proposed scheme. With OCDMA technologies, separate ONU-internetworking groups can be established using different optical codes. We also give experiment results to analyze the performance of the ONU-ONU transmission at different power of interference signals when two ONU-internetworking groups are present in the OCDMA-PON.

  8. Magnetic resonance ventriculography with gadolinium DTPA: report of two cases

    International Nuclear Information System (INIS)

    Siebner, H.R.; Einsiedel, H. von; Conrad, B.

    1997-01-01

    We report intrathecal use of gadolinium DTPA for MRI of the cerebrospinal fluid (CSF). In two patients with leptomeningeal carcinomatosis, we injected 0.01 mmol gadolinium DTPA into the lateral ventricle via an Ommaya device. Coronal T1-weighted images of the head were obtained at 0.2 T prior to and after injection. There was pronounced enhancement of CSF close to the injection site, allowing good delineation of CSF and surrounding brain tissue. No side effects occurred. MRI with intrathecal administration of highly diluted gadolinium DTPA may be a promising alternative to conventional investigation of CSF-filled cavities using iodinated X-ray contrast media or radionuclides. (orig.). With 3 figs

  9. Two-frequency operation of a hybrid TEA CO2 laser and its application to two-frequency pulse injection locking

    International Nuclear Information System (INIS)

    Sasaki, Koichi; Ohno, Hirotaka; Fujii, Takaharu; Tsukishima, Takashige.

    1990-10-01

    Simultaneous two-frequency oscillation of a hybrid TEA CO 2 laser is exhibited when the cw section is operated in a 'below threshold' state. The output of the hybrid laser thus obtained is injected into a main TEA CO 2 laser to obtain a power-modulated, long-pulse output with a well suppressed gain-switched spike. (author)

  10. A Retrospective Analysis of Cyanoacrylate Injection versus Hemoclip Placement for Bleeding Dieulafoy’s Lesion in Duodenum

    Directory of Open Access Journals (Sweden)

    Yu Jiang

    2018-01-01

    Full Text Available Background. Duodenal Dieulafoy’s lesion (DL is a rare disease that may lead to lethal hemorrhage in the upper gastrointestinal tract. The best technique for endoscopic intervention still remains unclear. In the present study, we performed a retrospective analysis of cyanoacrylate injection versus hemoclip placement for treating bleeding DLs. Materials and Methods. We retrospectively analyzed eighteen patients from three medical centers between October 2008 and February 2016; six patients received cyanoacrylate injection, while hemoclips were placed in 12 patients during the upper gastrointestinal endoscopy. Results. All patients received first endoscopic examination and/or endotherapy within 12 hours of admission to hospital. No difference was observed in the primary hemostasis rate or the recurrent hemorrhage rate between the cyanoacrylate injection (CI group and the hemoclip placement (HP group, except that in one patient from the HP group melena was found three days after the first endotherapy. This patient received cyanoacrylate injection once again. Conclusion. Both cyanoacrylate injection and hemoclip placement are effective in treating duodenal DL, and neither of them causes significant side effects.

  11. Double-sided microtron at Nihon University

    International Nuclear Information System (INIS)

    Tanaka, T.; Hayakawa, K.; Yatoh, H.; Yoshida, K.; Takeda, O.; Sato, K.; Torizuka, Y.

    1990-01-01

    Construction of a 35 MeV cw double-sided microtron (DSM) at Nihon University was started in 1984 and completed in the spring of 1989. This machine was constructed as a proto-type of an 1 GeV cw double sided microtron for a medical pion facility and test accelerator for FEL and other applications. The 4.55 MeV electron beam from 5 MeV injector linac is injected to the DSM. The energy gain is 6 MeV at each turn acceleration. After recirculated 5 times, the electron beam with 34.5 MeV is extracted at the final short straight section. The DAW structure is used for all the accelerating tubes including the injector linac. Total rf power of 200 kW is provided by four 50 kW klystrons of 2450 MHz. (author)

  12. Sexual and injection-related risks in Puerto Rican-born injection drug users living in New York City: A mixed-methods analysis

    Directory of Open Access Journals (Sweden)

    Gelpí-Acosta Camila

    2011-10-01

    Full Text Available Abstract Background These data were collected as part of the National HIV Behavioral Surveillance (NHBS study. NHBS is a cross-sectional study to investigate HIV behavioral risks among core risk groups in 21 U.S. cities with the highest HIV/AIDS prevalence. This analysis examines data from the NHBS data collection cycle with IDU conducted in New York City in 2009. We explored how the recency of migration from Puerto Rico (PR to New York City (NYC impacts both syringe sharing and unprotected sex among injection drug users (IDU currently living in NYC. Methods We used a mixed-methods approach to examine differences in risk between US-born IDU, PR IDU who migrated to NYC more than three years ago (non-recent migrants, and PR IDU who migrated in the last three years (recent migrants. Respondent-driven sampling (RDS was used to recruit the sample (n = 514. In addition, qualitative individual and group interviews with recent PR migrants (n = 12 and community experts (n = 2 allowed for an in-depth exploration of the IDU migration process and the material and cultural factors behind continued risk behaviors in NYC. Results In multiple logistic regression controlling for confounding factors, recent migrants were significantly more likely to report unprotected sexual intercourse with casual or exchange partners (adjusted odds ratio [AOR]: 2.81; 95% confidence intervals [CI]: 1.37-5.76 and receptive syringe sharing (AOR = 2.44; 95% CI: 1.20-4.97 in the past year, compared to US-born IDU. HIV and HCV seroprevalence were highest among non-recent migrants. Qualitative results showed that risky injection practices are partly based on cultural norms acquired while injecting drugs in Puerto Rico. These same results also illustrate how homelessness influences risky sexual practices. Conclusions Poor material conditions (especially homelessness may be key in triggering risky sexual practices. Cultural norms (ingrained while using drugs in PR around injection drug

  13. Water injection device for reactor container

    International Nuclear Information System (INIS)

    Sakaki, Isao.

    1996-01-01

    A pressure vessel incorporating a reactor core is placed and secured on a pedestal in a dry well of a reactor container. A pedestal water injection line is disposed opened at one end in a pedestal cavity passing through the side wall of the pedestal and led at the other end to the outside of the reactor container. A substitution dry well spray line is connected to a spray header disposed at the upper portion of the dry well. When the pressure vessel should be damaged by a molten reactor core and the molten reactor core should drop to the dry well upon occurrence of an accident, the molten reactor core on the floor of the pedestal is cooled by water injection from the pedestal water injection line. At the same time, the elevation of the pressure and the temperature in the reactor container is suppressed by the water injection of the substitution dry well spray line. This can avoid large scaled release of radioactive materials to the environmental circumference. (I.N.)

  14. Surface topography acquisition method for double-sided near-right-angle structured surfaces based on dual-probe wavelength scanning interferometry.

    Science.gov (United States)

    Zhang, Tao; Gao, Feng; Jiang, Xiangqian

    2017-10-02

    This paper proposes an approach to measure double-sided near-right-angle structured surfaces based on dual-probe wavelength scanning interferometry (DPWSI). The principle and mathematical model is discussed and the measurement system is calibrated with a combination of standard step-height samples for both probes vertical calibrations and a specially designed calibration artefact for building up the space coordinate relationship of the dual-probe measurement system. The topography of the specially designed artefact is acquired by combining the measurement results with white light scanning interferometer (WLSI) and scanning electron microscope (SEM) for reference. The relative location of the two probes is then determined with 3D registration algorithm. Experimental validation of the approach is provided and the results show that the method is able to measure double-sided near-right-angle structured surfaces with nanometer vertical resolution and micrometer lateral resolution.

  15. Warpage investigation on side arms using response surface methodology (RSM) and glow-worm swarm optimizations (GSO)

    Science.gov (United States)

    Sow, C. K.; Fathullah, M.; Nasir, S. M.; Shayfull, Z.; Shazzuan, S.

    2017-09-01

    This paper discusses on an analysis run via injection moulding process in determination of the optimum processing parameters used for manufacturing side arms of catheters in minimizing the warpage issues. The optimization method used was RSM. Moreover, in this research tries to find the most significant factor affecting the warpage. From the previous literature review,4 most significant parameters on warpage defect was selected. Those parameters were melt temperature, packing time, packing pressure, mould temperature and cooling time. At the beginning, side arm was drawn using software of CATIA V5. Then, software Mouldflow and Design Expert were employed to analyses on the popular warpage issues. After that, GSO artificial intelligence was apply using the mathematical model from Design Expert for more optimization on RSM result. Recommended parameter settings from the simulation work were then compared with the optimization work of RSM and GSO. The result show that the warpage on the side arm was improved by 3.27 %

  16. Flexural Strength of Acrylic Resin Denture Bases Processed by Two Different Methods

    Directory of Open Access Journals (Sweden)

    Jafar Gharechahi

    2014-09-01

    Full Text Available Background and aims. The aim of this study was to compare flexural strength of specimens processed by conventional and injection-molding techniques. Materials and methods. Conventional pressure-packed PMMA was used for conventional pressure-packed and injection-molded PMMA was used for injection-molding techniques. After processing, 15 specimens were stored in distilled water at room temperature until measured. Three-point flexural strength test was carried out. Statistical analysis was carried out by SPSS using t-test. Statistical significance was defined at P<0.05. Results. Flexural strength of injection-polymerized acrylic resin specimens was higher than that of theconventional method (P=0.006. This difference was statistically significant (P=0.006. Conclusion. Within the limitations of this study, flexural strength of acrylic resin specimens was influenced by the mold-ing technique.

  17. General Method for Calculating the Response and Noise Spectra of Active Fabry-Perot Semiconductor Waveguides With External Optical Injection

    DEFF Research Database (Denmark)

    Blaaberg, Søren; Mørk, Jesper

    2009-01-01

    We present a theoretical method for calculating small-signal modulation responses and noise spectra of active Fabry-Perot semiconductor waveguides with external light injection. Small-signal responses due to either a modulation of the pump current or due to an optical amplitude or phase modulatio...... amplifiers and an injection-locked laser. We also demonstrate the applicability of the method to analyze slow and fast light effects in semiconductor waveguides. Finite reflectivities of the facets are found to influence the phase changes of the injected microwave-modulated light....

  18. A brief review on the efficacy of different possible and nonpharmacological techniques in eliminating discomfort of local anesthesia injection during dental procedures

    Science.gov (United States)

    Davoudi, Amin; Rismanchian, Mansour; Akhavan, Ali; Nosouhian, Saeid; Bajoghli, Farshad; Haghighat, Abbas; Arbabzadeh, Farahnaz; Samimi, Pouran; Fiez, Atiyeh; Shadmehr, Elham; Tabari, Kasra; Jahadi, Sanaz

    2016-01-01

    Dental anxiety and fear of needle injection is one of the most common problems encountered by dental practitioners, especially in the pediatric patient. In consequences, it might affect the patient's quality of life. Several methods are suggested to lower the discomfort of local anesthesia injection during dental procedures. Desensitization of injection site is one of the recommended strategies. Among chemical anesthetic topical agents that are effective but might have allergic side effects, using some nonpharmacological and safe techniques might be useful. This study aimed to overview the efficacy of using cooling techniques, mostly by ice or popsicles, warming or pH buffering of drug, and using modern devices to diminish the discomfort of local anesthesia injection during dental procedures. PMID:26957683

  19. Two-dimensional analysis of two-phase reacting flow in a firing direct-injection diesel engine

    Science.gov (United States)

    Nguyen, H. Lee

    1989-01-01

    The flow field, spray penetration, and combustion in two-stroke diesel engines are described. Fuel injection begins at 345 degrees after top dead center (ATDC) and n-dodecane is used as the liquid fuel. Arrhenius kinetics is used to calculate the reaction rate term in the quasi-global combustion model. When the temperature, fuel, and oxygen mass fraction are within suitable flammability limits, combustion begins spontaneously. No spark is necessary to ignite a localized high temperature region. Compression is sufficient to increase the gaseous phase temperature to a point where spontaneous chemical reactions occur. Results are described for a swirl angle of 22.5 degrees.

  20. Active stabilization of a diode laser injection lock.

    Science.gov (United States)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-06-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser's transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  1. FINELY DISPERSED COMPOSITE BINDER FOR REINFORCING SOILS BY INJECTION METHOD

    Directory of Open Access Journals (Sweden)

    Kharchenko Igor Yakovlevich

    2017-11-01

    Full Text Available Subject: we consider the problem of supplying the construction industry, in particular underground construction, with mineral binder for diluted aqueous suspensions that meet the requirements for reinforcement of low-strength sand and clastic soils by injections into the reinforced soil mass. Research objectives: substantiating possibility of using amorphous biosilica in combination with carbide sludge, whose particles size does not exceed 10 mm on average, as a binder for aqueous suspensions being injected. Materials and methods: as raw materials we used: common construction hydrated lime from “Stroimaterialy” JSC, Belgorod, hydrated lime in the form of carbide sludge from the dumps of Protvino plant (carbide sludge, hereafter, active mineral admixture biosilica from the group of companies “DIAMIX” and a plasticizer Sika viscocrete 5 new. Test methods are in accordance with applicable standards. To obtain samples of impregnated soils, a specially developed technique was used in the form of a unidirectional model. Results: properties of the composite binder prepared with different compositions are presented. The optimal component ratios are determined. The following properties of aqueous suspensions are studied: conditional viscosity, sedimentation and penetrating ability. Conditional viscosity is no more than 40 sec on average. Sedimentation does not exceed 1.2 %. Soil-concrete obtained by injection of a dilute aqueous suspension based on this composite binder has a compressive strength in the range from 4.44 to 12.5 MPa. Conclusions: utilization of finely dispersed composite mineral binder, which is based on interaction of amorphous silica with calcium hydroxide, as a binder for high penetration aqueous suspensions has been substantiated. This binder is not inferior to foreign analogues in terms of its strength and technological parameters and can be used for reinforcement of loose and low-strength soils. In case of using carbide

  2. Compliance and use behaviour, an issue in injectable as well as oral contraceptive use? A study of injectable and oral contraceptive use in Johannesburg.

    Science.gov (United States)

    Beksinska, M E; Rees, V H; Nkonyane, T; McIntyre, J A

    1998-04-01

    This study examines the compliance, use behaviour and knowledge of method of women using injectable and oral contraceptives in two clinic sites in the Johannesburg area, South Africa. An interviewer administered questionnaire was used to collect information in the clients' home language. A total of 400 women were interviewed in the clinics. The mean age of clients was 26.2 years (range 13 to 43 years). Of the clients not wanting to get pregnant, 30.4 per cent of injectable users and 18.4 per cent of oral contraceptive (OC) users had stopped using their method temporarily before returning to the same method (called the nonuse segment) and had not used any other form of contraception during this time. Almost one third of injectable users (31.2 per cent) had been late for their next injection at least once. Although nearly all women using injectables had experienced some menstrual disturbances, over one third (38.5 per cent) had not been informed by the providers about the possibility of these changes. Many women gave the disruption of their menstrual cycle as the reason for the nonuse segment. The majority of OC users lacked information on how to use their method correctly. Nearly all women expressed an interest in obtaining more information on their current method and other available methods. This study shows that compliance is an issue in injectable as well as OC users.

  3. Cell force mapping using a double-sided micropillar array based on the moiré fringe method

    Science.gov (United States)

    Zhang, F.; Anderson, S.; Zheng, X.; Roberts, E.; Qiu, Y.; Liao, R.; Zhang, X.

    2014-07-01

    The mapping of traction forces is crucial to understanding the means by which cells regulate their behavior and physiological function to adapt to and communicate with their local microenvironment. To this end, polymeric micropillar arrays have been used for measuring cell traction force. However, the small scale of the micropillar deflections induced by cell traction forces results in highly inefficient force analyses using conventional optical approaches; in many cases, cell forces may be below the limits of detection achieved using conventional microscopy. To address these limitations, the moiré phenomenon has been leveraged as a visualization tool for cell force mapping due to its inherent magnification effect and capacity for whole-field force measurements. This Letter reports an optomechanical cell force sensor, namely, a double-sided micropillar array (DMPA) made of poly(dimethylsiloxane), on which one side is employed to support cultured living cells while the opposing side serves as a reference pattern for generating moiré patterns. The distance between the two sides, which is a crucial parameter influencing moiré pattern contrast, is predetermined during fabrication using theoretical calculations based on the Talbot effect that aim to optimize contrast. Herein, double-sided micropillar arrays were validated by mapping mouse embryo fibroblast contraction forces and the resulting force maps compared to conventional microscopy image analyses as the reference standard. The DMPA-based approach precludes the requirement for aligning two independent periodic substrates, improves moiré contrast, and enables efficient moiré pattern generation. Furthermore, the double-sided structure readily allows for the integration of moiré-based cell force mapping into microfabricated cell culture environments or lab-on-a-chip devices.

  4. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  5. Flow injection spectrofluorimetric method for the determination of cadmium

    International Nuclear Information System (INIS)

    Bo Tang; Taixing Yue; Lili Zhang; Junsen Wu; Zhenzhen Chen

    2004-01-01

    A novel fluorescent reagent, o-vanillin furoylhydrazone (OVFH), was synthesized, and its infrared spectrum, elemental analysis and dissociation constant are reported. The reaction between Cd 2+ and OVFH produces an intensely fluorescent complex in ethanol-water medium of pH 10.00, and this finding has led to a simple, rapid, and sensitive flow injection (FI) spectrofluorimetric method for on-line determination of Cd 2+ . Under the optimum experimental conditions, the fluorescent complex had excitation and emission maxima at 393 and 494 nm, respectively. The linear range is from 0.025 to 8.0 μg mL -1 of Cd 2+ , the detection limit is 7.6 μg L -1 and the maximum sampling rate is 80 h -1 . The effect of interferences was studied. The method was successfully applied to the determination of cadmium in environmental samples. (author)

  6. Ultrasound and Histologic Examination after Subcutaneous Injection of Two Volumizing Hyaluronic Acid Fillers: A Preliminary Study

    Science.gov (United States)

    Besse, Stéphanie; Sarazin, Didier; Quinodoz, Pierre; Elias, Badwi; Safa, Marva; Vandeputte, Joan

    2017-01-01

    Background: This study examined the influence of hyaluronic acid (HA) crosslinking technology on the ultrasound and histologic behavior of HA fillers designed for subcutaneous injection. Methods: One subject received subcutaneous injections of 0.25 ml Cohesive Polydensified Matrix (CPM) and Vycross volumizing HA in tissue scheduled for abdominoplasty by bolus and retrograde fanning techniques. Ultrasound analyses were performed on days 0 and 8 and histologic analyses on days 0 and 21 after injection. A series of simple rheologic tests was also performed. Results: Day 0 ultrasound images after bolus injection showed CPM and Vycross as hypoechogenic papules in the hypodermis. CPM appeared little changed after gentle massage, whereas Vycross appeared more hyperechogenic and diminished in size. Ultrasound images at day 8 were similar. On day 0, both gels appeared less hypoechogenic after retrograde fanning than after bolus injection. Vycross was interspersed with hyperechogenic areas (fibrous septa from the fat network structure) and unlike CPM became almost completely invisible after gentle massage. On day 8, CPM appeared as a hypoechogenic pool and Vycross as a long, thin rod. Day 0 histologic findings confirmed ultrasound results. Day 21 CPM histologic findings showed a discrete inflammatory reaction along the injection row after retrograde fanning. Vycross had a more pronounced inflammatory reaction, particularly after retrograde fanning, with macrophages and giant cells surrounding the implant. Rheologic tests showed CPM to have greater cohesivity and resistance to traction forces than Vycross. Conclusions: CPM HA volumizer appears to maintain greater tissue integrity than Vycross after subcutaneous injection with less inflammatory activity. PMID:28280664

  7. Percutaneous Ethanol Injection of Unresectable Medium-to-Large-Sized Hepatomas Using a Multipronged Needle: Efficacy and Safety

    International Nuclear Information System (INIS)

    Ho, C.S.; Kachura, J.R.; Gallinger, S.; Grant, D.; Greig, P.; McGilvray, I.; Knox, J.; Sherman, M.; Wong, F.; Wong, D.

    2007-01-01

    Fine needles with an end hole or multiple side holes have traditionally been used for percutaneous ethanol injection (PEI) of hepatomas. This study retrospectively evaluates the safety and efficacy of PEI of unresectable medium-to-large (3.5-9 cm) hepatomas using a multipronged needle and with conscious sedation. Twelve patients, eight men and four women (age 51-77 years; mean: 69) received PEI for hepatomas, mostly subcapsular or exophytic in location with average tumor size of 5.6 cm (range: 3.5-9.0 cm). Patients were consciously sedated and an 18G retractable multipronged needle (Quadrafuse needle; Rex Medical, Philadelphia, PA) was used for injection under real-time ultrasound guidance. By varying the length of the prongs and rotating the needle, the alcohol was widely distributed within the tumor. The progress of ablation was monitored by contrast-enhanced ultrasound, computed tomography (CT) or magnetic resonance imaging (MRI) after each weekly injection and within a month after the final (third) injection and 3 months thereafter. An average total of 63 mL (range: 20-154 ml) of alcohol was injected per patient in an average of 2.3 sessions. Contrast-enhanced CT, ultrasound, or MRI was used to determine the degree of necrosis. Complete necrosis was noted in eight patients (67%), near-complete necrosis (90-99%) in two (16.7%), and partial success (50-89%) in two (16.7%). Follow-up in the first 9 months showed local recurrence in two patients and new lesions in another. There was no mortality. One patient developed renal failure, liver failure, and localized perforation of the stomach. He responded to medical treatment and surgery was not required for the perforation. One patient had severe postprocedural abdominal pain and fever, and another had transient hyperbilirubinemia; both recovered with conservative treatment. PEI with a multipronged needle is a new, safe, and efficacious method in treating medium-to-large-sized hepatocellular carcinoma under conscious

  8. Reduced injection pressures using a compressed air injection technique (CAIT): an in vitro study.

    Science.gov (United States)

    Tsui, Ban C H; Knezevich, Mark P; Pillay, Jennifer J

    2008-01-01

    High injection pressures have been associated with intraneural injection and persistent neurological injury in animals. Our objective was to test whether a reported simple compressed air injection technique (CAIT) would limit the generation of injection pressures to below a suggested 1,034 mm Hg limit in an in vitro model. After ethics board approval, 30 consenting anesthesiologists injected saline into a semiclosed system. Injection pressures using 30 mL syringes connected to a 22 gauge needle and containing 20 mL of saline were measured for 60 seconds using: (1) a typical "syringe feel" method, and (2) CAIT, thereby drawing 10 mL of air above the saline and compressing this to 5 mL prior to and during injections. All anesthesiologists performed the syringe feel method before introduction and demonstration of CAIT. Using CAIT, no anesthesiologist generated pressures above 1,034 mm Hg, while 29 of 30 produced pressures above this limit at some time using the syringe feel method. The mean pressure using CAIT was lower (636 +/- 71 vs. 1378 +/- 194 mm Hg, P = .025), and the syringe feel method resulted in higher peak pressures (1,875 +/- 206 vs. 715 +/- 104 mm Hg, P = .000). This study demonstrated that CAIT can effectively keep injection pressures under 1,034 mm Hg in this in vitro model. Animal and clinical studies will be needed to determine whether CAIT will allow objective, real-time pressure monitoring. If high pressure injections are proven to contribute to nerve injury in humans, this technique may have the potential to improve the safety of peripheral nerve blocks.

  9. Stopped-flow injection method for determination of phosphate in soils and fertilisers

    Directory of Open Access Journals (Sweden)

    Jaroon Jakmunee

    2008-02-01

    Full Text Available A stopped-flow injection system for the determination of phosphate has been developed. It involves the phosphate-molybdate-ascorbic acid reactions in the molybdenum blue method. The system is controlled by a semi-automatic stopped-FI analyser with a light emitting diode (LED-colorimeter for monitoring the absorbance change relating to the concentration of a reaction product formed during the stopping period while the injected zone of a standard or sample is being in the flow cell. The slope of the FIAgram obtained is linearly proportional to the reaction rate, which depends on the phosphate concentration. Effects of concentration of reagents, viz. sodium molybdate, ascorbic acid and nitric acid, on the slope of the FIAgram were studied. The suitable concentration is 0.02 M, 0.25 %w/v and 0.15 M, respectively. A linear calibration graph in the range of 0.3-6.0 mg P L-1 was employed for the determination of phosphate in soil and fertiliser samples. The results obtained agree well with those from a standard spectrophotometric method.

  10. Synthesis and property characterization of two novel side-chain isoindigo copolymers for polymer solar cells

    Directory of Open Access Journals (Sweden)

    X. Liu

    2015-11-01

    Full Text Available Two novel side-chain conjugated polymers, PTBT-TID and PTBT-TTID, based on the new synthetic thiophene-benzne-thiophene (TBT unit, side-chain isoindigo (ID unit, and the introduced thiophene π-bridge, have been designed and synthesized. The photophysical, electrochemical and photovoltaic properties of the two polymers have been systematically investigated. The two polymers possess relatively good solubility as well as excellent thermal stability up to 380°C, and all of the polymer solar cell (PSC devices based on the two polymers obtain high open circuit voltage (Voc of about 0.8 V. The polymer solar cells based on the polymer PTBT-TID show relatively higher efficiencies than the PTBT-TTID-based ones, due to the broader absorption spectrum, a relatively higher hole mobility, a lower HOMO (the highest occupied molecular orbital energy level, a stronger IPCE (the incident photon to current conversion efficiency response and a better microphase separation, Consequently, the device based on PTBT-TID:PC61BM (1:2, by weight gives the best power conversion efficiency (PCE of 2.04%, with a short-circuit current density (Jsc of 5.39 mA·cm–2, an open-circuit voltage (Voc of 0.83 V, and a fill factor (FF of 0.45.

  11. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  12. Rapid colorimetric assay for gentamicin injection.

    Science.gov (United States)

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  13. Dimensional accuracy optimization of the micro-plastic injection molding process using the Taguchi design method

    Directory of Open Access Journals (Sweden)

    Chil-Chyuan KUO KUO

    2015-06-01

    Full Text Available Plastic injection molding is an important field in manufacturing industry because there are many plastic products that produced by injection molding. However, the time and cost required for producing a precision mold are the most troublesome problems that limit the application at the development stage of a new product in precision machinery industry. This study presents an approach of manufacturing a hard mold with microfeatures for micro-plastic injection molding. This study also focuses on Taguchi design method for investigating the effect of injection parameters on the dimensional accuracy of Fresnel lens during plastic injection molding. It was found that the dominant factor affecting the microgroove depth of Fresnel lens is packing pressure. The optimum processing parameters are packing pressure of 80 MPa, melt temperature of 240 °C, mold temperature of 90 °C and injection speed of 50 m/s. The dimensional accuracy of Fresnel lens can be controlled within ±3 µm using the optimum level of process parameters through the confirmation test. The research results of this study have industrial application values because electro-optical industries are able to significantly reduce a new optical element development cycle time.DOI: http://dx.doi.org/10.5755/j01.ms.21.2.5864

  14. A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

    Science.gov (United States)

    Liang, Qin-Qin; Li, Yong-Sheng

    2013-12-01

    An accurate and rapid method and a system to determine protein content using asynchronous-injection alternating merging zone flow-injection spectrophotometry based on reaction between coomassie brilliant blue G250 (CBBG) and protein was established. Main merit of our approach is that it can avoid interferences of other nitric-compounds in samples, such as melamine and urea. Optimized conditions are as follows: Concentrations of CBBG, polyvinyl alcohol (PVA), NaCl and HCl are 150 mg/l, 30 mg/l, 0.1 mol/l and 1.0% (v/v), respectively; volumes of the sample and reagent are 150 μl and 30 μl, respectively; length of a reaction coil is 200 cm; total flow rate is 2.65 ml/min. The linear range of the method is 0.5-15 mg/l (BSA), its detection limit is 0.05 mg/l, relative standard deviation is less than 1.87% (n=11), and analytical speed is 60 samples per hour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Effects of turbulence enhancement on combustion process using a double injection strategy in direct-injection spark-ignition (DISI) gasoline engines

    International Nuclear Information System (INIS)

    Kim, Taehoon; Song, Jingeun; Park, Sungwook

    2015-01-01

    Highlights: • Using double injection strategy, turbulent kinetic energy can be improved with slight decrease in mixture homogeneity. • Retarded first injection timing reduces vapor fuel loss to intake port. • Double injection increases tumble intensity. • High turbulent intensity caused by double injection increases flame propagation speed. - Abstract: Direct-injection spark-ignition (DISI) gasoline engines have been spotlighted due to their high thermal efficiency. Increase in the compression ratio that result from the heat absorption effect of fuel vaporization induces higher thermal efficiency than found in port fuel injection (PFI) engines. Since fuel is injected at the cylinder directly, various fuel injection strategies can be used. In this study, turbulent intensity was improved by a double injection strategy while maintaining mixture homogeneity. To analyze the turbulence enhancement effects using the double injection strategy, a side fuel injected, homogeneous-charge-type DISI gasoline engine with a multi-hole-type injector was utilized. The spray model was evaluated using experimental data for various injection pressures and the combustion model was evaluated for varied ignition timing. First and second injection timing was swept by 20 degree interval. The turbulent kinetic energy and mixture inhomogeneity index were mapped. First injection at the middle of the intake stroke and second injection early in the compression stroke showed improved turbulent characteristics that did not significantly decrease with mixture homogeneity. A double injection case that showed improved turbulent intensity while maintaining an adequate level of mixture homogeneity and another double injection case that showed significantly improved turbulent intensity with a remarkable decrease in mixture homogeneity were considered for combustion simulation. We found that the improved turbulent intensity increased the flame propagation speed. Also, the mixture homogeneity

  16. Ionic liquid and aqueous two-phase extraction based on salting-out coupled with high-performance liquid chromatography for the determination of seven rare ginsenosides in Xue-Sai-Tong injection.

    Science.gov (United States)

    Li, Lan-Jie; Jin, Yong-Ri; Wang, Xiao-Zhong; Liu, Ying; Wu, Qian; Shi, Xiao-Lei; Li, Xu-Wen

    2015-09-01

    A method of ionic liquid salt aqueous two-phase extraction coupled with high-performance liquid chromatography has been developed for the analysis of seven rare ginsenosides including Rg6 , F4 , 20(S)-Rg3 , 20(R)-Rg3 , Rk3 , Rk1 , and Rg5 in Xue-Sai-Tong injection. The injection was mixed with ionic liquid 1-butyl-3-methylimidazolium bromide aqueous solution, and a mixture was obtained. With the addition of sodium dodecyl sulfate and dipotassium phosphate into the mixture, the aqueous two-phase mixture was formed after ultrasonic treatment and centrifuged. Rare ginsenosides were extracted into the upper phase. To obtain a high extraction factors, various influences were considered systematically, such as the volume of ionic liquid, the category and amount of salts, the amount of sodium dodecyl sulfate, the pH value of system, and the time of ultrasonic treatment. Under the optimal condition, rare ginsenosides in Xue-Sai-Tong injection were enriched and detected, the recoveries of seven rare ginsenosides ranged from 90.05 to 112.55%, while relative standard deviations were lower than 2.50%. The developed method was reliable, rapid and sensitive for the determination of seven rare ginsenosides in the injections. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Efficacy and safety of cross-linked hyaluronic acid single injection on osteoarthritis of the knee: a post-marketing Phase IV study.

    Science.gov (United States)

    Bashaireh, Khaldoon; Naser, Ziad; Hawadya, Khaled Al; Sorour, Sorour; Al-Khateeb, Rami Nabeel

    2015-01-01

    The primary objective of this study was to evaluate the efficacy, safety, and duration of action of viscosupplementation with Crespine® Gel over a 9-month period. The study was a post-marketing Phase IV study. A total of 109 participants with osteoarthritis of the knee (grades 1-4) in the tibio-femoral compartment were recruited in Jordan. Data were collected from each participant during the baseline visit. Each participant received Crespine® Gel injection, and follow-up visits took place at 3 months, 6 months, and 9 months post-injection. An assessment of participants by phone was conducted at 1 month, 2 months, 4 months, 5 months, 7 months, and 8 months post-injection. Western Ontario and McMaster Universities Arthritis Index questionnaires were completed during each visit. A 72-hour visit questionnaire was used to assess the safety of the injection. Statistical analysis included a two-sided 95% confidence interval for the difference between pain scores across visits, and the percent change from baseline was calculated. The full analysis included 84 participants who gave their informed consent and finished the necessary baseline and follow-up visits needed to assess efficacy and safety. Peak improvement was noted at 5 months post-injection, when pain and physical performance scores had decreased to 2.60 and 9.90, respectively, and the stiffness score was 0.33. The peak improvement in stiffness was noted at 8 months post-injection, when the stiffness score had decreased to 0.32. Significant improvements were still apparent at 9 months post-injection, when the pain score was 3.36, the stiffness score was 0.42, and the physical performance score was 11.5. All side effects were local and transient, and included pain, swelling, and redness of the knee. Most side effects were treated. Hyaluronan should be encouraged as an alternative or adjunct treatment to oral analgesics to reduce their required doses, and delay potential future surgical intervention.

  18. Novel air-injection technique to locate the medial cut end of lacerated canaliculus.

    Science.gov (United States)

    Liu, Bingqian; Li, Yonghao; Long, Chongde; Wang, Zhonghao; Liang, Xuanwei; Ge, Jian; Wang, Zhichong

    2013-12-01

    Locating the medial cut end of the severed canaliculus is the most difficult aspect of canalicular repair, especially in patients with more medial laceration, severe oedema, persistent errhysis and a narrow canaliculus. Irrigation is a widely used technique to identify the cut end; however, we found that air injected through the intact canaliculus with a straight needle failed to reflux when the common canaliculus or lacrimal sac was not blocked. We describe a simple, safe and efficient air-injection technique to identify the medial cut edge of a lacerated canaliculus. In this method, we initially submersed the medial canthus under normal saline, then injected filtered air through the intact canaliculus using a side port stainless steel probe with a closed round tip. The tip was designed to block the common canaliculus to form a relatively closed system. The efficiency of this novel air-injection technique was equivalent to the traditional technique but does not require the cooperation of the patient to blow air. Using this technique, the medial cut end was successfully identified by locating the air-bubble exit within minutes in 19 cases of mono-canalicular laceration without any complication.

  19. The control of plasma density profile in Tore Supra. Comparison of different fueling techniques; Controle du profil de densite dans le plasma de Tore Supra. Comparaison de differentes methodes d'alimentation en particules

    Energy Technology Data Exchange (ETDEWEB)

    Commaux, N

    2007-09-15

    The behaviour of a reactor-class plasma when fuelled using the existing techniques (gas puffing, supersonic molecular beam injection and pellet injection) is still very difficult to foresee. The present work has been initiated on Tore Supra in order to extrapolate the consequences of the different fuelling systems on ITER. Two main topics have been studied: the comparison of the plasma behaviour when fuelled using the different techniques at high Greenwald density fractions and the study of the homogenization following a pellet injection (main fuelling technique for ITER burning plasmas). The experiments at high Greenwald density fractions performed on Tore Supra showed that the plasma behaviour is very dependent on the fuelling method. The plasma energy confinement is following the scaling laws determined at low density when fuelled using pellet injection. which is better than for gas puffing and SMBI. both inducing a significant confinement loss. This behaviour is nor related to a transport modification: the ratio between effective diffusion and convection is similar to the pellet case. The difference between these shots is related only to the position of the matter source (at the edge for gas and close to the center for pellets). The study concerning the homogenization phenomena following a pellet injection aims mainly to study the {nabla}B-drift effect that expels the mater deposited by a pellet toward the low field side. A new phenomenon. which appears to be particularly important for the {nabla}B-drift during low field side injections. was then discovered: the influence of magnetic surfaces with an integer-valued safety factor (q). When the mater drifting toward low field side crosses an integer q surface. it experiences an important braking effect which stops the drift motion. It implies that the pellet material is mainly deposited on the last integer q surface crossed by the pellet during its injection. This study allows also to determine that the {nabla

  20. Coupled Viscous Fluid Flow and Joint Deformation Analysis for Grout Injection in a Rock Joint

    Science.gov (United States)

    Kim, Hyung-Mok; Lee, Jong-Won; Yazdani, Mahmoud; Tohidi, Elham; Nejati, Hamid Reza; Park, Eui-Seob

    2018-02-01

    Fluid flow modeling is a major area of interest within the field of rock mechanics. The main objective of this study is to gain insight into the performance of grout injection inside jointed rock masses by numerical modeling of grout flow through a single rock joint. Grout flow has been widely simulated using non-Newtonian Bingham fluid characterized by two main parameters of dynamic viscosity and shear yield strength both of which are time dependent. The increasing value of these properties with injection time will apparently affect the parameters representing the grouting performance including grout penetration length and volumetric injection rate. In addition, through hydromechanical coupling a mutual influence between the injection pressure from the one side and the joint opening/closing behavior and the aperture profile variation on the other side is anticipated. This is capable of producing a considerable impact on grout spread within the rock joints. In this study based on the Bingham fluid model, a series of numerical analysis has been conducted using UDEC to simulate the flow of viscous grout in a single rock joint with smooth parallel surfaces. In these analyses, the time-dependent evolution of the grout fluid properties and the hydromechanical coupling have been considered to investigate their impact on grouting performance. In order to verify the validity of these simulations, the results of analyses including the grout penetration length and the injection flow rate were compared with a well-known analytical solution which is available for the simple case of constant grout properties and non-coupled hydraulic analysis. The comparison demonstrated that the grout penetration length can be overestimated when the time-dependent hardening of grout material is not considered. Moreover, due to the HM coupling, it was shown that the joint opening induced by injection pressure may have a considerable increasing impression on the values of penetration length and

  1. A new series of two-ring-based side chain liquid crystalline polymers: synthesis and mesophase characterization

    CSIR Research Space (South Africa)

    Reddy, GSM

    2013-05-01

    Full Text Available A new series of side chain liquid crystalline polymers containing a core, a butamethylenoxy spacer, ester groups, and terminal alkoxy groups were synthesised and their structures were confirmed. The core was constructed with two phenyl rings...

  2. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Winniford, Michael D

    2013-02-08

    smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study

  3. Roads may act as barriers to flying insects: species composition of bees and wasps differs on two sides of a large highway

    Directory of Open Access Journals (Sweden)

    Petter Andersson

    2017-07-01

    Full Text Available Roads may act as barriers to animal movements, but direct barrier effects on insects have rarely been studied. In this study we collected data on bees and wasps along two sides of a large road in Sweden using yellow pan traps. We then analyzed if the species composition differed between the two sides of the road; first for the whole community, and then only for the smallest species (which typically are poorer dispersers. As a complement, we analyzed if different vegetation variables differed between the two sides of the road, as this may also affect differences in species composition. Finally, we analyzed if species richness and abundance in general differed between the two sides and how these two response variables were explained by the vegetation variables. There was a significant difference in species composition between the eastern and the western side of the road when analyzing the whole community, and this relationship became even stronger when the largest species were excluded. The vegetation variables did not strongly differ between the two sides, and there was no difference in species richness and abundance of bees and wasps either. Abundance was, however, explained by the number of flowering plants in the surroundings of the trap. Even though using a rather limited data set, our results indicate that large roads may act as barriers on the movement of bees and wasps, especially for small species with poor dispersal ability. On the other hand, road verges may be important habitat for many species, which leads to a potential conflict that is important to consider in the planning of green infrastructure.

  4. Correlation of In Vivo and In Vitro Methods in Measuring Choroidal Vascularization Volumes Using a Subretinal Injection Induced Choroidal Neovascularization Model

    Directory of Open Access Journals (Sweden)

    Chuang Nie

    2015-01-01

    Full Text Available Background: In vivo quantification of choroidal neovascularization (CNV based on noninvasive optical coherence tomography (OCT examination and in vitro choroidal flatmount immunohistochemistry stained of CNV currently were used to evaluate the process and severity of age-related macular degeneration (AMD both in human and animal studies. This study aimed to investigate the correlation between these two methods in murine CNV models induced by subretinal injection. Methods: CNV was developed in 20 C57BL6/j mice by subretinal injection of adeno-associated viral delivery of a short hairpin RNA targeting sFLT-1 (AAV.shRNA.sFLT-1, as reported previously. After 4 weeks, CNV was imaged by OCT and fluorescence angiography. The scaling factors for each dimension, x, y, and z (μm/pixel were recorded, and the corneal curvature standard was adjusted from human (7.7 to mice (1.4. The volume of each OCT image stack was calculated and then normalized by multiplying the number of voxels by the scaling factors for each dimension in Seg3D software (University of Utah Scientific Computing and Imaging Institute, available at http://www.sci.utah.edu/cibc-software/seg3d.html. Eighteen mice were prepared for choroidal flatmounts and stained by CD31. The CNV volumes were calculated using scanning laser confocal microscopy after immunohistochemistry staining. Two mice were stained by Hematoxylin and Eosin for observing the CNV morphology. Results: The CNV volume calculated using OCT was, on average, 2.6 times larger than the volume calculated using the laser confocal microscopy. The correlation statistical analysis showed OCT measuring of CNV correlated significantly with the in vitro method (R 2 =0.448, P = 0.001, n = 18. The correlation coefficient for CNV quantification using OCT and confocal microscopy was 0.693 (n = 18, P = 0.001. Conclusions: There is a fair linear correlation on CNV volumes between in vivo and in vitro methods in CNV models induced by subretinal

  5. Study of the usefulness on liver CT using intermittent bolus injection method

    International Nuclear Information System (INIS)

    Hayashi, Hideo

    1990-01-01

    Usefulness on the liver CT using intermittent bolus injection method of contrast media (IM-CE) was studied in 108 hepatic space occupying lesions, particularly to analyze hepatocellular carcinoma (HCC). Scans were obtained before, 20∼30 (arterial phase) and 60 seconds (parenchymal phase) after intravenous bolus injection of 65%-diatrizoate (angiografin) or 300 mg I-iopamidol (iopamiron 300), and in case of necessity, added 3∼15 minutes (late phase) after all injections of contrast media. These scans imaging the features of hepatic mass provided us much useful information. Early enhancement of the arterial phase, and early wash out of the parenchymal phase and delayed ring enhancement of the capsule improved the rates of detection to 96%, 60%, and 49% respectively in case of HCC. Especially. at the small HCC (less than 2cm in diameter), these rates were 89%, 50%, and 28% respectively. Combination of these 3 findings suggested the possibility of HCC in comparison with other hepatic mass. The rate of accurate diagnosis of HCC by this IM-CE was 81%. Thus IM-CE CT provides the useful information in diagnosis of hepatic mass and should be considered as the routine examination of hepatic mass. (author)

  6. Studying Intense Pulsed Light Method Along With Corticosteroid Injection in Treating Keloid Scars

    OpenAIRE

    Shamsi Meymandi, Simin; Rezazadeh, Azadeh; Ekhlasi, Ali

    2014-01-01

    Background: Results of various studies suggest that the hypertrophic and keloid scars are highly prevalent in the general population and are irritating both physically and mentally. Objective: Considering the variety of existing therapies, intense pulsed light (IPL) method along with corticosteroid injection was evaluated in treating these scars. Materials and Methods: 86 subjects were included in this clinical trial. Eight sessions of therapeutic intervention were done with IPL along with co...

  7. Application of reliability analysis methods to the comparison of two safety circuits

    International Nuclear Information System (INIS)

    Signoret, J.-P.

    1975-01-01

    Two circuits of different design, intended for assuming the ''Low Pressure Safety Injection'' function in PWR reactors are analyzed using reliability methods. The reliability analysis of these circuits allows the failure trees to be established and the failure probability derived. The dependence of these results on test use and maintenance is emphasized as well as critical paths. The great number of results obtained may allow a well-informed choice taking account of the reliability wanted for the type of circuits [fr

  8. Production of 67Ga citrate injection liquid with butylacetate extraction method

    International Nuclear Information System (INIS)

    Fang Yibing; Li Bo; Liu Peng; Pan Qiyuan; Liu Peihua; Wang Han; Feng Jingling

    1995-01-01

    The distribution ratios D for Ga(III) at trace concentration in the HCl-butylacetate extraction system are measured. It showed that the D in 6 mol/l HCl is 5 x 10 2 which is maximum in 3-8 mol/l HCl. The extraction rates E in 5.5-8 mol/l HCl at phase ratio of 1 are ≥98% and ≥96% respectively when the concentration of ZnCl 2 in the solution are 0 and ≤2 mol/l. A butylacetate extraction method for the production of 67 Ga citrate injection liquid from Zn target irradiated by proton beam is developed. The optimal acidity of extraction is 6 mol/l HCl. The concentration of ZnCl 2 is adjusted to ≤2.0 mol/l and the impurity of Fe(III) in solution is reduced to Fe(II) with 10% TiCl 3 before extraction. The 67 Ga in organic phase is then stripped with water. The radionuclidic purity of the product is 100% while the radiochemical purity >90%. The amounts of Zn, Ti, Fe, Cu, Cd and Pb in the injection are below or near 1 mg/l. The test of abnormal toxicity is negative. The quality of the injection meets the requirements of both the Chinese and the United States Pharmacopoeia. The chemical yield is (92 +- 2)% while the time of operation is <3 h

  9. Active stabilization of a diode laser injection lock

    Energy Technology Data Exchange (ETDEWEB)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep [Department of Physics, University of Washington, P.O. Box 351560, Seattle, Washington 98195-1560 (United States)

    2016-06-15

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  10. Active stabilization of a diode laser injection lock

    International Nuclear Information System (INIS)

    Saxberg, Brendan; Plotkin-Swing, Benjamin; Gupta, Subhadeep

    2016-01-01

    We report on a device to electronically stabilize the optical injection lock of a semiconductor diode laser. Our technique uses as discriminator the peak height of the laser’s transmission signal on a scanning Fabry-Perot cavity and feeds back to the diode current, thereby maintaining maximum optical power in the injected mode. A two-component feedback algorithm provides constant optimization of the injection lock, keeping it robust to slow thermal drifts and allowing fast recovery from sudden failures such as temporary occlusion of the injection beam. We demonstrate the successful performance of our stabilization method in a diode laser setup at 399 nm used for laser cooling of Yb atoms. The device eases the requirements on passive stabilization and can benefit any diode laser injection lock application, particularly those where several such locks are employed.

  11. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  12. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...

  13. Photoelectric schlieren method used to study the properties of diesel engine injection systems

    International Nuclear Information System (INIS)

    Reznicek, R.

    1987-01-01

    The time dependence of the fuel flow rate issuing from the injector nozzle represents very important information concerning the properties of Diesel engine injection systems. By analysing the delivery rate, it is possible to judge a new design, and the modifications and adjustments of Diesel engine injection systems. A number of devices for measuring the delivery rate, frequently founded on mechanical principles, have also been constructed. Mechanical methods are laborious, require complicated measuring instruments, and the analysis of the results is quite tedious. For investigating the delivery rate, one can also use the intensity of the luminous flux of the light ray which is intersected, and consequently its intensity decreased, by the flow of the delivered fuel. The schlieren method can be used for this purpose, employing a thin beam of parallel light rays and a photoelectric sensor placed immediately beyond the cut-off slit. After adjustment and calibration, the variations of the original electric signal represent the time variation of the delivery rate by the nozzle

  14. Physician and patient benefit–risk preferences from two randomized long-acting injectable antipsychotic trials

    Directory of Open Access Journals (Sweden)

    Katz EG

    2016-10-01

    Full Text Available Eva G Katz,1 Brett Hauber,2 Srihari Gopal,3 Angie Fairchild,2 Amy Pugh,4 Rachel B Weinstein,3 Bennett S Levitan3 1Janssen Research & Development, LLC, Raritan, NJ, 2RTI Health Solutions, Research Triangle Park, NC, 3Janssen Research & Development, LLC, Titusville, NJ, 4The University of California, San Francisco (UCSF, CA, USA Purpose: To quantify clinical trial participants’ and investigators’ judgments with respect to the relative importance of efficacy and safety attributes of antipsychotic treatments for schizophrenia, and to assess the impact of formulation and adherence.Methods: Discrete-choice experiment surveys were completed by patients with schizophrenia and physician investigators participating in two phase-3 clinical trials of paliperidone palmitate 3-month long-acting injectable (LAI antipsychotic. Respondents were asked to choose between hypothetical antipsychotic profiles defined by efficacy, safety, and mode of administration. Data were analyzed using random-parameters logit and probit models.Results: Patients (N=214 and physicians (N=438 preferred complete improvement in positive symptoms (severe to none as the most important attribute, compared with improvement in any other attribute studied. Both respondents preferred 3-month and 1-month injectables to oral formulation (P<0.05, irrespective of prior adherence to oral antipsychotic treatment, with physicians showing greater preference for a 3-month over a 1-month LAI for nonadherent patients. Physicians were willing to accept treatments with reduced efficacy for patients with prior poor adherence. The maximum decrease in efficacy (95% confidence interval [CI] that physicians would accept for switching a patient from daily oral to 3-month injectable was as follows: adherent: 9.8% (95% CI: 7.2–12.4, 20% nonadherent: 25.4% (95% CI: 21.0–29.9, and 50% nonadherent: >30%. For patients, adherent: 10.1% (95% CI: 6.1–14.1, nonadherent: the change in efficacy studied was

  15. About methods to reduce emissions of turbo charged engine gasoline direct injection

    Science.gov (United States)

    Neacsu, D.; Ivan, F.; Niculae, M.

    2017-08-01

    The paper aims to analyse and explain new methods applied on gasoline direct injection to reduce gas emissions and greenhouse effect. There are analysed the composition of emission inside the engine and which are the most harmful emission for the environment. Will be analysed the methods and systems which have a contribution to decrease emissions produced by the mixture of air and fuel. The paper contains details about after treatment systems which are designed to decrease gas emissions without any other negative consequence on the environment.

  16. Bolus injections of measured amounts of radioactivity

    International Nuclear Information System (INIS)

    Wesolowski, C.A.; Hogendoorn, P.; Vandierendonck, R.; Driedger, A.A.

    1988-01-01

    Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics

  17. 18FDG-PET in 733 consecutive patients with or without side-by-side CT evaluation. Analysis of 921 lesions

    International Nuclear Information System (INIS)

    Buell, U.; Wieres, F.J.; Schneider, W.; Reinartz, P.

    2004-01-01

    Side-by-side analysis of CT and conventional 18 FDG-PET in oncological imaging is well established. Aim of this study was to find out which patients or diagnostic groups may benefit the most from the newly introduced integrated PET/CT scanners. Patients, methods: 407 consecutively admitted oncological patients with accompanying CT (groups A-D) and 326 patients without CT (groups E-G) were examined by conventional ring PET. Two nuclear medicine physicians and two radiologists assessed each patient's PET and CT scans for pathological lesions with regard to localisation and infiltration of adjacent anatomical structures. Patients without pathological PET findings were assigned to groups A (with CT) or E (without CT). If the localisation and/or extent of a pathological PET focus could only be assessed by taking into account the CT scan, the patient was assigned to group C (with CT) or G (without CT). If PET alone was sufficient for both questions the patient was assigned to groups B (with CT) or F (without CT). If neither method allowed for a precise lesion characterisation, the patient was assigned to group D. Results: 38.6% (A, E) of all patients were PET-negative. PET alone sufficed in 20.6% (B, F). Side-by-side reading of PET and CT was needed for 43.5% (C) of patients referred to PET with a current CT. Side-by-side reading of CT and PET did not suffice for 7.3% (D) of patients in that cohort. A total of 28.2% (G) of the cases without CT would have profited from it. The most frequent oncological diagnoses in group D (PET and conventional CT not sufficient) were bronchial carcinoma with abdominal lesions, while in group G (without CT but CT required) head/neck cancer with thoracic lesions was predominant. Conclusions: Side-by-side reading of PET and already existing conventional CT failed to yield conclusive data with regard to lesion characterisation in only 7.4% of patients so that PET/CT might have been helpful in these cases. 28.2% of the patients without

  18. Local corticosteroid injections: Rational use in common orthopaedic ...

    African Journals Online (AJOL)

    The use of local corticosteroid injections in orthopaedic practice is common due to their anti- inflammatory and analgesic effect. However, the use may result in local or systemic complications. Moreover, the conflicting reports on their benefits versus side effects, throws the average user in confusion or fear. This review ...

  19. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage ...

  20. A Single Sided Edge Marking Method for Detecting Pectoral Muscle in Digital Mammograms

    Directory of Open Access Journals (Sweden)

    G. Toz

    2018-02-01

    Full Text Available In the computer-assisted diagnosis of breast cancer, the removal of pectoral muscle from mammograms is very important. In this study, a new method, called Single-Sided Edge Marking (SSEM technique, is proposed for the identification of the pectoral muscle border from mammograms. 60 mammograms from the INbreast database were used to test the proposed method. The results obtained were compared for False Positive Rate, False Negative Rate, and Sensitivity using the ground truth values pre-determined by radiologists for the same images. Accordingly, it has been shown that the proposed method can detect the pectoral muscle border with an average of 95.6% sensitivity.

  1. Development of devices for self-injection: using tribological analysis to optimize injection force

    Directory of Open Access Journals (Sweden)

    Lange J

    2016-05-01

    Full Text Available Jakob Lange, Leos Urbanek, Stefan BurrenYpsomed Delivery Systems, Ypsomed AG, Burgdorf, Switzerland Abstract: This article describes the use of analytical models and physical measurements to characterize and optimize the tribological behavior of pen injectors for self-administration of biopharmaceuticals. One of the main performance attributes of this kind of device is its efficiency in transmitting the external force applied by the user on to the cartridge inside the pen in order to effectuate an injection. This injection force characteristic is heavily influenced by the frictional properties of the polymeric materials employed in the mechanism. Standard friction tests are available for characterizing candidate materials, but they use geometries and conditions far removed from the actual situation inside a pen injector and thus do not always generate relevant data. A new test procedure, allowing the direct measurement of the coefficient of friction between two key parts of a pen injector mechanism using real parts under simulated use conditions, is presented. In addition to the absolute level of friction, the test method provides information on expected evolution of friction over lifetime as well as on expected consistency between individual devices. Paired with an analytical model of the pen mechanism, the frictional data allow the expected overall injection system force efficiency to be estimated. The test method and analytical model are applied to a range of polymer combinations with different kinds of lubrication. It is found that material combinations used without lubrication generally have unsatisfactory performance, that the use of silicone-based internal lubricating additives improves performance, and that the best results can be achieved with external silicone-based lubricants. Polytetrafluoroethylene-based internal lubrication and external lubrication are also evaluated but found to provide only limited benefits unless used in

  2. Water quality considerations resulting in the impaired injectivity of water injection and disposal wells

    International Nuclear Information System (INIS)

    Bennion, D.B.; Thomas, F.B.; Imer, D.; Ma, T.

    2000-01-01

    An environmentally responsible way to improve hydrocarbon recovery is to maintain pressure by water injection. This is a desirable method because unwanted produced water from oil and gas wells can be re-injected into producing or disposal formations. The success of the operation, however, depends on injecting the necessary volume of water economically, below the fracture gradient pressure of the formation. Well placement, geometry and inherent formation quality and relative permeability characteristics are some of the many other factors which influence the success of any injection project. Poor injection or poor quality of disposal water can also compromise the injectivity for even high quality sandstone or carbonate formations. This would necessitate costly workovers and recompletions. This paper presented some leading edge diagnostic techniques and evaluation methods to determine the quality of injected water. The same techniques could be used to better understand the effect of potential contaminants such as suspended solids, corrosion products, skim/carryover oil and grease, scales, precipitates, emulsions, oil wet hydrocarbon agglomerates and many other conditions which cause injectivity degradation. 14 refs., 1 tab., 15 figs

  3. A side-effect free method for identifying cancer drug targets.

    Science.gov (United States)

    Ashraf, Md Izhar; Ong, Seng-Kai; Mujawar, Shama; Pawar, Shrikant; More, Pallavi; Paul, Somnath; Lahiri, Chandrajit

    2018-04-27

    Identifying effective drug targets, with little or no side effects, remains an ever challenging task. A potential pitfall of failing to uncover the correct drug targets, due to side effect of pleiotropic genes, might lead the potential drugs to be illicit and withdrawn. Simplifying disease complexity, for the investigation of the mechanistic aspects and identification of effective drug targets, have been done through several approaches of protein interactome analysis. Of these, centrality measures have always gained importance in identifying candidate drug targets. Here, we put forward an integrated method of analysing a complex network of cancer and depict the importance of k-core, functional connectivity and centrality (KFC) for identifying effective drug targets. Essentially, we have extracted the proteins involved in the pathways leading to cancer from the pathway databases which enlist real experimental datasets. The interactions between these proteins were mapped to build an interactome. Integrative analyses of the interactome enabled us to unearth plausible reasons for drugs being rendered withdrawn, thereby giving future scope to pharmaceutical industries to potentially avoid them (e.g. ESR1, HDAC2, F2, PLG, PPARA, RXRA, etc). Based upon our KFC criteria, we have shortlisted ten proteins (GRB2, FYN, PIK3R1, CBL, JAK2, LCK, LYN, SYK, JAK1 and SOCS3) as effective candidates for drug development.

  4. Study on mixed analysis method for fatigue analysis of oblique safety injection nozzle on main piping

    International Nuclear Information System (INIS)

    Lu Xifeng; Zhang Yixiong; Ai Honglei; Wang Xinjun; He Feng

    2014-01-01

    The simplified analysis method and the detailed analysis method were used for the fatigue analysis of the nozzle on the main piping. Because the structure of the oblique safety injection nozzle is complex and some more severe transients are subjected. The results obtained are more penalized and cannot be validate when the simplified analysis method used for the fatigue analysis. It will be little conservative when the detailed analysis method used, but it is more complex and time-consuming and boring labor. To reduce the conservatism and save time, the mixed analysis method which combining the simplified analysis method with the detailed analysis method is used for the fatigue analysis. The heat transfer parameters between the fluid and the structure which used for analysis were obtained by heat transfer property experiment. The results show that the mixed analysis which heat transfer property is considered can reduce the conservatism effectively, and the mixed analysis method is a more effective and practical method used for the fatigue analysis of the oblique safety injection nozzle. (authors)

  5. High Frequency Voltage Injection Methods and Observer Design for Initial Position Detection of Permanent Magnet Synchronous Machines

    DEFF Research Database (Denmark)

    Jin, Xinhai; Ni, Ronggang; Chen, Wei

    2018-01-01

    The information of the initial rotor position is essential for smooth start up and robust control of Permanent Magnet Synchronous Machines (PMSMs). RoTating Voltage Injection (RTVI) methods in the stationary reference frame have been commonly adopted to detect the initial rotor position at stands......The information of the initial rotor position is essential for smooth start up and robust control of Permanent Magnet Synchronous Machines (PMSMs). RoTating Voltage Injection (RTVI) methods in the stationary reference frame have been commonly adopted to detect the initial rotor position...

  6. Non-parathyroid hypercalcemia associated with paraffin oil injection in 12 younger male bodybuilders

    DEFF Research Database (Denmark)

    Sølling, Anne Sophie Koldkjær; Tougaard, Birgitte G; Harsløf, Torben

    2018-01-01

    INTRODUCTION: Injection of paraffin oil to augment muscles size is a troubling phenomenon known to cause a foreign body reaction with formation of granulomas. In a few case reports, long-term side effects have been reported in terms of hypercalcemia and renal failure. METHODS: We identified a case...... the normal range or slightly elevated. Follow-up measurements showed marked hypercalciuria with nearly normal levels of bone turnover markers. A correlation was found between levels of peptidyl dipeptidase and calcitriol (R = 0.812, P = 0.050). Treatment with antiresorptive agents seemed less effective than...

  7. A facile electrode preparation method for accurate electrochemical measurements of double-side-coated electrode from commercial Li-ion batteries

    Science.gov (United States)

    Zhou, Ge; Wang, Qiyu; Wang, Shuo; Ling, Shigang; Zheng, Jieyun; Yu, Xiqian; Li, Hong

    2018-04-01

    The post mortem electrochemical analysis, including charge-discharge and electrochemical impedance spectroscopy (EIS) measurements, are critical steps for revealing the failure mechanisms of commercial lithium-ion batteries (LIBs). These post measurements usually require the reassembling of coin-cell with electrode which is often double-side-coated in commercial LIBs. It is difficult to use such double-side-coated electrode to perform accurate electrochemical measurements because the back side of the electrode is coated with active materials, rather than single-side-coated electrode that is often used in coin-cell measurements. In this study, we report a facile tape-covering sample preparation method, which can effectively suppress the influence of back side of the double-side-coated electrodes on capacity and EIS measurements in coin-cells. By tape-covering the unwanted side, the areal capacity of the desired investigated side of the electrode has been accurately measured with an experimental error of about 0.5% at various current densities, and accurate EIS measurements and analysis have been conducted as well.

  8. Comparison of Oone-Stage Free Gracilis Muscle Flap With Two-Stage Method in Chronic Facial Palsy

    Directory of Open Access Journals (Sweden)

    J Ghaffari

    2007-08-01

    Full Text Available Background:Rehabilitation of facial paralysis is one of the greatest challenges faced by reconstructive surgeons today. The traditional method for treatment of patients with facial palsy is the two-stage free gracilis flap which has a long latency period of between the two stages of surgery.Methods: In this paper, we prospectively compared the results of the one-stage gracilis flap method with the two -stage technique.Results:Out of 41 patients with facial palsy refered to Hazrat-e-Fatemeh Hospital 31 were selected from whom 22 underwent two- stage and 9 one-stage method treatment. The two groups were identical according to age,sex,intensity of illness, duration, and chronicity of illness. Mean duration of follow up was 37 months. There was no significant relation between the two groups regarding the symmetry of face in repose, smiling, whistling and nasolabial folds. Frequency of complications was equal in both groups. The postoperative surgeons and patients' satisfaction were equal in both groups. There was no significant difference between the mean excursion of muscle flap in one-stage (9.8 mm and two-stage groups (8.9 mm. The ratio of contraction of the affected side compared to the normal side was similar in both groups. The mean time of the initial contraction of the muscle flap in the one-stage group (5.5 months had a significant difference (P=0.001 with the two-stage one (6.5 months.The study revealed a highly significant difference (P=0.0001 between the mean waiting period from the first operation to the beginning of muscle contraction in one-stage(5.5 monthsand two-stage groups(17.1 months.Conclusion:It seems that the results and complication of the two methods are the same,but the one-stage method requires less time for facial reanimation,and is costeffective because it saves time and decreases hospitalization costs.

  9. Initial position estimation method for permanent magnet synchronous motor based on improved pulse voltage injection

    DEFF Research Database (Denmark)

    Wang, Z.; Lu, K.; Ye, Y.

    2011-01-01

    According to saliency of permanent magnet synchronous motor (PMSM), the information of rotor position is implied in performance of stator inductances due to the magnetic saturation effect. Researches focused on the initial rotor position estimation of PMSM by injecting modulated pulse voltage...... vectors. The relationship between the inductance variations and voltage vector positions was studied. The inductance variation effect on estimation accuracy was studied as well. An improved five-pulses injection method was proposed, to improve the estimation accuracy by choosing optimaized voltage vectors...

  10. Numerical simulation in steam injection process by a mechanistic approach

    Energy Technology Data Exchange (ETDEWEB)

    De Souza, J.C.Jr.; Campos, W.; Lopes, D.; Moura, L.S.S. [Petrobras, Rio de Janeiro (Brazil)

    2008-10-15

    Steam injection is a common thermal recovery method used in very viscous oil reservoirs. The method involves the injection of heat to reduce viscosity and mobilize oil. A steam generation and injection system consists primarily of a steam source, distribution lines, injection wells and a discarding tank. In order to optimize injection and improve the oil recovery factor, one must determine the parameters of steam flow such as pressure, temperature and steam quality. This study focused on developing a unified mathematical model by means of a mechanistic approach for two-phase steam flow in pipelines and wells. The hydrodynamic and heat transfer mechanistic model was implemented in a computer simulator to model the parameters of steam injection while trying to avoid the use of empirical correlations. A marching algorithm was used to determine the distribution of pressure and temperature along the pipelines and wellbores. The mathematical model for steam flow in injection systems, developed by a mechanistic approach (VapMec) performed well when the simulated values of pressures and temperatures were compared with the values measured during field tests. The newly developed VapMec model was incorporated in the LinVap-3 simulator that constitutes an engineering supporting tool for steam injection wells operated by Petrobras. 23 refs., 7 tabs., 6 figs.

  11. Nonlinear dynamics of solitary and optically injected two-element laser arrays with four different waveguide structures: a numerical study.

    Science.gov (United States)

    Li, Nianqiang; Susanto, H; Cemlyn, B R; Henning, I D; Adams, M J

    2018-02-19

    We study the nonlinear dynamics of solitary and optically injected two-element laser arrays with a range of waveguide structures. The analysis is performed with a detailed direct numerical simulation, where high-resolution dynamic maps are generated to identify regions of dynamic instability in the parameter space of interest. Our combined one- and two-parameter bifurcation analysis uncovers globally diverse dynamical regimes (steady-state, oscillation, and chaos) in the solitary laser arrays, which are greatly influenced by static design waveguiding structures, the amplitude-phase coupling factor of the electric field, i.e. the linewidth-enhancement factor, as well as the control parameter, e.g. the pump rate. When external optical injection is introduced to one element of the arrays, we show that the whole system can be either injection-locked simultaneously or display rich, different dynamics outside the locking region. The effect of optical injection is to significantly modify the nature and the regions of nonlinear dynamics from those found in the solitary case. We also show similarities and differences (asymmetry) between the oscillation amplitude of the two elements of the array in specific well-defined regions, which hold for all the waveguiding structures considered. Our findings pave the way to a better understanding of dynamic instability in large arrays of lasers.

  12. Improving Injectable Medicines Prescription in Outpatient Services: A Path Towards Rational Use of Medicines in Iran

    Science.gov (United States)

    Bairami, Firoozeh; Soleymani, Fatemeh; Rashidian, Arash

    2016-01-01

    Injection is one of the most common medical procedures in the health sector. Annually up to 16 billion injections are prescribed in low- and middle-income countries (LMICs), many of them are not necessary for the patients, increase the healthcare costs and may result in side effects. Currently over 40% of outpatient prescriptions in Iran contain at least one injectable medicine. To address the issue, a working group was established (August 2014 to April 2015) to provide a comprehensive policy brief to be used by national decision-makers. This report is the extract of methods that were followed and the main policy options for improving injectable medicines prescribing in outpatient services. Thirty-three potential policy options were developed focusing on different stakeholders. The panel reached consensus on seven policy options, noting effectiveness, cost, durability, and feasibility of each policy. The recommended policy options are targeted at patients and public (2 policies), insurers (2), physicians (1), pharmacies (1), and the Ministry of Health and Medical Education (MoHME) (1). PMID:27239881

  13. Improving Injectable Medicines Prescription in Outpatient Services: A Path Towards Rational Use of Medicines in Iran

    Directory of Open Access Journals (Sweden)

    Firoozeh Bairami

    2016-05-01

    Full Text Available Injection is one of the most common medical procedures in the health sector. Annually up to 16 billion injections are prescribed in low- and middle-income countries (LMICs, many of them are not necessary for the patients, increase the healthcare costs and may result in side effects. Currently over 40% of outpatient prescriptions in Iran contain at least one injectable medicine. To address the issue, a working group was established (August 2014 to April 2015 to provide a comprehensive policy brief to be used by national decision-makers. This report is the extract of methods that were followed and the main policy options for improving injectable medicines prescribing in outpatient services. Thirty-three potential policy options were developed focusing on different stakeholders. The panel reached consensus on seven policy options, noting effectiveness, cost, durability, and feasibility of each policy. The recommended policy options are targeted at patients and public (2 policies, insurers (2, physicians (1, pharmacies (1, and the Ministry of Health and Medical Education (MoHME (1.

  14. Long-acting injectable antipsychotics: focus on olanzapine pamoate

    Directory of Open Access Journals (Sweden)

    JP Lindenmayer

    2010-05-01

    Full Text Available JP LindenmayerDepartment of Psychiatry, New York University School of Medicine, New York NY, USAAbstract: Medication non-adherence in patients with schizophrenia continues to be a significant problem and threatens successful treatment outcomes. Medication non-adherence is often associated with negative consequences, including symptom exacerbation, more frequent emergency room visits, re-hospitalizations and relapse. Long-acting injectable (LAI forms of antipsychotics allow for rapid identification of non-adherence, obviate the need for the patient to take the medication on a daily basis and increase adherence to some significant degree. Eli Lilly has developed a long-acting depot formulation of olanzapine, olanzapine pamoate, which has recently been approved by the FDA for the US market, and which will be reviewed here. Olanzapine LAI appears to be an effective antipsychotic at dosages of 210 mg every 2 weeks, 300 mg every 2 weeks and 405 mg every 4 weeks in patients with acute schizophrenia, and at 150 mg every 2 weeks, 300 mg every 2 weeks and at 405 mg every 4 weeks for the maintenance treatment of stable patients. Oral supplementation appears not to be needed, particularly not at the onset of treatment with the LAI as is necessary with risperidone LAI. Its efficacy is in general comparable to the efficacy seen with oral olanzapine at a corresponding dose. The side effect profile is also comparable to the side effects observed with oral olanzapine, including lower rates of extrapyramidal symptoms, prolactin elevation and cardiovascular side effects, but significant metabolic effects. The latter include significant weight gain, lipid abnormalities and glucose dysregulation. While the injection site adverse events are overall mild, the most significant serious adverse event is the post-injection delirium sedation syndrome (PDSS. While rare, this syndrome results from inadvertent intravascular injection of olanzapine LAI and can cause a range of

  15. Myositis complicating benzathine penicillin-G injection in a case of rheumatic heart disease

    Directory of Open Access Journals (Sweden)

    Joshua R. Francis

    2016-01-01

    Full Text Available A 7-year old boy developed myositis secondary to intramuscular injection of benzathine penicillin-G in the context of secondary prophylaxis for rheumatic heart disease. Side effects of intramuscular delivery of benzathine penicillin-G are well described and include injection site pain and inflammation, but myositis, as depicted on magnetic resonance imaging in this case, has not previously been described.

  16. Treatment of Palatal Myoclonus with Botulinum Toxin Injection

    Directory of Open Access Journals (Sweden)

    Mursalin M. Anis

    2013-01-01

    Full Text Available Palatal myoclonus is a rare cause of pulsatile tinnitus in patients presenting to the otolaryngology office. Rhythmic involuntary contractions of the palatal muscles produce the pulsatile tinnitus in these patients. Treatment of this benign but distressing condition with anxiolytics, anticonvulsants, and surgery has been largely unsuccessful. A few investigators have obtained promising results with botulinum toxin injection into the palatal muscles. We present a patient with palatal myoclonus who failed conservative treatment with anxiolytics. Unilateral injection of botulinum toxin into her tensor veli palatini muscle under electromyographic guidance resolved pulsatile tinnitus in her ipsilateral ear and unmasked pulsatile tinnitus in the contralateral ear. A novel method of following transient postinjection symptoms using a diary is presented in this study. Botulinum toxin dose must be titrated to achieve optimal results in each individual patient, analogous to titrations done for spasmodic dysphonia. Knowledge of the temporal onset of postinjection side effects and symptomatic relief may aid physicians in dose titration and surveillance. We present suggestions on titrating the botulinum toxin dose to optimal levels. A review of the literature on the use of botulinum toxin for palatal myoclonus and some common complications are discussed.

  17. Prospective unmasked randomized evaluation of the iStent inject® versus two ocular hypotensive agents in patients with primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Fea AM

    2014-05-01

    Full Text Available Antonio M Fea,1 Jose I Belda,2 Marek Rękas,3 Anselm Jünemann,4 Lydia Chang,5 Luis Pablo,6 Lilit Voskanyan,7 L Jay Katz81Università degli Studi di Torino, Clinica Oculistica, Torino, Italy; 2Hospital Torrevieja Salud, UTE, Servicio de Oftalmologia, Alicante, Spain; 3Military Institute of Medicine, Department of Ophthalmology, Warsaw, Poland; 4Universitätsaugenklinik, Erlangen, Germany; 5Hinchingbrooke Hospital NHS Trust and Moorfields Bedford Hospital NHS Trust, United Kingdom; 6Hospital Universitario Miguel Servet, Servicio Oftalmologico, Zaragoza, Spain; 7SV Malayan Ophthalmological Center, Yerevan, Armenia; 8Wills Eye Institute, Jefferson Medical College, Philadelphia, PA, USAPurpose: The purpose of this study was to compare outcomes of subjects with open-angle glaucoma (OAG not controlled on one medication who underwent either implantation of two iStent inject® trabecular micro-bypass devices or received medical therapy consisting of a fixed combination of latanoprost/timolol.Patients and methods: Of 192 subjects who qualified for the study and were enrolled, 94 were randomized to surgery with implantation of two iStent inject® devices in the treated eye and 98 to receive medical therapy.Results: At the month 12 visit, 94.7% of eyes (89/94 in the stent group reported an unmedicated intraocular pressure (IOP reduction of ≥20% versus baseline unmedicated IOP, and 91.8% of eyes (88/98 in the medical therapy group reported an IOP reduction ≥20% versus baseline unmedicated IOP. A 17.5% between-group treatment difference in favor of the iStent inject group was statistically significant (P=0.02 at the ≥50% level of IOP reduction. An IOP ≤18 mmHg was reported in 92.6% of eyes (87/94 in the iStent inject group and 89.8% of eyes (88/98 in the medical therapy group. Mean (standard deviation IOP decreases from screening of 8.1 (2.6 mmHg and 7.3 (2.2 mmHg were reported in the iStent inject and medical therapy groups, respectively. A high

  18. The hexatron, a six-sided 4-GeV 300-μA CW microtron

    International Nuclear Information System (INIS)

    Colton, E.P.; Crosbie, E.A.; Foss, M.

    1984-01-01

    The use of microtron accelerators to provide intense CW beams of electrons with energies in the 1-5 GeV range is discussed. Principles of operation are reviewed and a design is presented for a six-sided hexagonal microtron, a Hexatron, which is capable of furnishing 300 μA of electrons in 3 extracted beams whose energies can be varied individually from injection energy to 4.0 GeV. Results of prototype studies of the hexatron sector magnets are discussed. Two configurations of beam optics, are shown to provide good beam containment. Options for operating the Hexatron at energies above 4 GeV are also discussed. (author)

  19. CT-guided percutaneous ethanol injection in the treatment of thyroid adenoma

    International Nuclear Information System (INIS)

    Zheng Jiasheng; Zhao Xia; Cui Xiongwei; Li Hua

    2001-01-01

    Objective: To evaluate the safety and efficacy of CT-guided percutaneous ethanol injection (CT-PEI) in the treatment of thyroid adenoma. Methods: Fifty-four patients with 73 nodules were included in the study. Thyroid adenoma was confirmed by pathology. The serum level T3, T4 and TSH were normal in all cases. CT-PEI (0.3-2.5 ml ethanol/cm 3 nodular tissue) was given for 115 times (mean 1.58 +- 0.78 times/nodule). Results: Complete cure was observed in 37 nodules (50.7%). In 28 nodules (38.3%) volume reduction was greater than 80%. A significant nodule reduction (50%-80%) was observed in 7 nodules. Only 1 (1.4%) nodule volume reduction was 28.9%. Apart from 1 case of transient dysphonia and 2 cases of mild pain and burning sensation, no side effect was observed. Conclusion: CT-PEI is a safe and effective therapeutic procedure with few side effects for thyroid adenoma

  20. Retrieval method of aerosol extinction coefficient profile based on backscattering, side-scattering and Raman-scattering lidar

    Science.gov (United States)

    Shan, Huihui; Zhang, Hui; Liu, Junjian; Tao, Zongming; Wang, Shenhao; Ma, Xiaomin; Zhou, Pucheng; Yao, Ling; Liu, Dong; Xie, Chenbo; Wang, Yingjian

    2018-03-01

    Aerosol extinction coefficient profile is an essential parameter for atmospheric radiation model. It is difficult to get higher signal to noise ratio (SNR) of backscattering lidar from the ground to the tropopause especially in near range. Higher SNR problem can be solved by combining side-scattering and backscattering lidar. Using Raman-scattering lidar, aerosol extinction to backscatter ratio (lidar ratio) can be got. Based on side-scattering, backscattering and Raman-scattering lidar system, aerosol extinction coefficient is retrieved precisely from the earth's surface to the tropopause. Case studies show this method is reasonable and feasible.

  1. Application of geophysical methods to the study of pollution associated with abandoned and injection wells

    International Nuclear Information System (INIS)

    Frischknecht, F.C.

    1990-01-01

    This paper reports on contamination of ground-water supplies by brine and other pollutants which is a serious problem in some oil-producing and industrial areas. Abandoned petroleum and water wells and active injection wells are often major elements in the contamination process. The casings of abandoned wells develop leaks, and, if not properly plugged, such wells sometimes serve as conduits for pollutants to reach freshwater aquifiers. Pollutants from waste-disposal sites or accidental spills may migrate down abandoned wells. Brines or other wastes injected into deep horizons may migrate up abandoned wells and reach aquifers containing potable water. Injection wells sometimes develop leaks and, if not carefully monitored, can pollute large volumes of earth materials before the effect is noted in production wells or at the surface. As a first step in the mitigation of these problems, methods of locating abandoned wells and mapping brine contamination from injection wells have been studied by the U.S. Geological Survey in cooperation with the U.S. Environmental Protection Agency (EPA)

  2. "Every method seems to have its problems"- Perspectives on side effects of hormonal contraceptives in Morogoro Region, Tanzania.

    Science.gov (United States)

    Chebet, Joy J; McMahon, Shannon A; Greenspan, Jesse A; Mosha, Idda H; Callaghan-Koru, Jennifer A; Killewo, Japhet; Baqui, Abdullah H; Winch, Peter J

    2015-11-03

    Family planning has been shown to be an effective intervention for promoting maternal, newborn and child health. Despite family planning's multiple benefits, women's experiences of - or concerns related to - side effects present a formidable barrier to the sustained use of contraceptives, particularly in the postpartum period. This paper presents perspectives of postpartum, rural, Tanzanian women, their partners, public opinion leaders and community and health facility providers related to side effects associated with contraceptive use. Qualitative interviews were conducted with postpartum women (n = 34), their partners (n = 23), community leaders (n = 12) and health providers based in both facilities (n = 12) and communities (n = 19) across Morogoro Region, Tanzania. Following data collection, digitally recorded data were transcribed, translated and coded using thematic analysis. Respondents described family planning positively due to the health and economic benefits associated with limiting and spacing births. However, side effects were consistently cited as a reason that women and their partners choose to forgo family planning altogether, discontinue methods, switch methods or use methods in an intermittent (and ineffective) manner. Respondents detailed side effects including excessive menstrual bleeding, missed menses, weight gain and fatigue. Women, their partners and community leaders also described concerns that contraceptives could induce sterility in women, or harm breastfeeding children via contamination of breast milk. Use of family planning during the postpartum period was viewed as particularly detrimental to a newborn's health in the first months of life. To meet Tanzania's national target of increasing contraceptive use from 34 to 60 % by 2015, appropriate counseling and dialogue on contraceptive side effects that speaks to pressing concerns outlined by women, their partners, communities and service providers are needed.

  3. Human Thrombin Injection for the Percutaneous Treatment of Iatrogenic Pseudoaneurysms

    International Nuclear Information System (INIS)

    Elford, Julian; Burrell, Christopher; Freeman, Simon; Roobottom, Carl

    2002-01-01

    Purpose: Thrombin injection is becoming well established for the percutaneous management of iatrogenic pseudoaneurysms. All the published series to date use bovine thrombin,and there have been reports of adverse immunologic effects following its use. Our study aimed to assess the efficacy of human thrombin injection for pseudoaneurysm occlusion. Methods:Fourteen patients with iatrogenic pseudoaneurysms underwent a color Doppler ultrasound examination to assess their suitability for percutaneous human thrombin injection. Human thrombin 1000 IU was then injected into the pseudoaneurysm sac under sterile conditions and with ultrasound guidance. A further color Doppler ultrasound examination was performed 24 hr later to confirm occlusion. Results: All 14 pseudoaneurysms were successfully occluded by human thrombin injection. In two cases a second injection of thrombin was required,but there were no other complications, and all pseudoaneurysms remained occluded at 24 hr. Conclusion: Ultrasound-guided human thrombin injection is simple to perform, effective and safe. We recommend that human thrombin becomes the agent of choice for percutaneous injection into iatrogenic pseudoaneurysms

  4. Metamodel-based design optimization of injection molding process variables and gates of an automotive glove box for enhancing its quality

    International Nuclear Information System (INIS)

    Kang, Gyung Ju; Park, Chang Hyun; Choi, Dong Hoon

    2016-01-01

    Injection molding process variables and gates of an automotive glove box were optimally determined to enhance its injection molding quality. We minimized warpage with satisfying constraints on clamp force, weldline, and profiles of filling and packing. Design variables concerning the injection molding process are temperatures of the mold and the resin, ram speeds, and packing pressures and durations; design variables concerning the gates are the shape of the center gate and locations of two side gates. To optimally determine the design variables in an efficient way, we adopted metamodel-based design optimization, sequentially using an optimal Latin hypercube design as a design of experiment, Kriging models as metamodels that replace time-consuming injection molding simulations, and a micro genetic algorithm as an optimization algorithm. In the optimization process, a commercial injection molding analysis software, MoldflowTM, was employed to evaluate the injection molding quality at design points specified. Using the proposed design approach, the warpage was found reduced by 20.5% compared to the initial warpage, while all the design constraints were satisfied, which clearly shows the validity of the proposed design approach

  5. Metamodel-based design optimization of injection molding process variables and gates of an automotive glove box for enhancing its quality

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Gyung Ju [Pusan National University, Busan (Korea, Republic of); Park, Chang Hyun; Choi, Dong Hoon [Hanyang University, Seoul (Korea, Republic of)

    2016-04-15

    Injection molding process variables and gates of an automotive glove box were optimally determined to enhance its injection molding quality. We minimized warpage with satisfying constraints on clamp force, weldline, and profiles of filling and packing. Design variables concerning the injection molding process are temperatures of the mold and the resin, ram speeds, and packing pressures and durations; design variables concerning the gates are the shape of the center gate and locations of two side gates. To optimally determine the design variables in an efficient way, we adopted metamodel-based design optimization, sequentially using an optimal Latin hypercube design as a design of experiment, Kriging models as metamodels that replace time-consuming injection molding simulations, and a micro genetic algorithm as an optimization algorithm. In the optimization process, a commercial injection molding analysis software, MoldflowTM, was employed to evaluate the injection molding quality at design points specified. Using the proposed design approach, the warpage was found reduced by 20.5% compared to the initial warpage, while all the design constraints were satisfied, which clearly shows the validity of the proposed design approach.

  6. A novel fault location scheme for power distribution system based on injection method and transient line voltage

    Science.gov (United States)

    Huang, Yuehua; Li, Xiaomin; Cheng, Jiangzhou; Nie, Deyu; Wang, Zhuoyuan

    2018-02-01

    This paper presents a novel fault location method by injecting travelling wave current. The new methodology is based on Time Difference Of Arrival(TDOA)measurement which is available measurements the injection point and the end node of main radial. In other words, TDOA is the maximum correlation time when the signal reflected wave crest of the injected and fault appear simultaneously. Then distance calculation is equal to the wave velocity multiplied by TDOA. Furthermore, in case of some transformers connected to the end of the feeder, it’s necessary to combine with the transient voltage comparison of amplitude. Finally, in order to verify the effectiveness of this method, several simulations have been undertaken by using MATLAB/SIMULINK software packages. The proposed fault location is useful to short the positioning time in the premise of ensuring the accuracy, besides the error is 5.1% and 13.7%.

  7. The efficacy of two bupivacaine hydrochloride injection products

    African Journals Online (AJOL)

    1996-06-06

    Jun 6, 1996 ... stances majority of o the survey t the time hamstrung g staff. itive hes to ... hydrochloride injection products was investigated in patients who ... upon the concentration, dose, route of application, and ... Practice guidelines.~.5 .... GUIdelines on Ihe Qualoty. safety and efficacy Of mra.cmal prOducts for human.

  8. Appropriateness of clinical and organizational criteria for intra-articular injection therapies in osteoarthritis: A Delphi method consensus initiative among experts in Italy

    Directory of Open Access Journals (Sweden)

    Marco Paoloni

    2015-06-01

    Full Text Available OBJECTIVE: The aim of the study was to identify the main aspects involved in patient selection, the choice of therapeutic agents and the safety profile, as well as the medico-legal and organizational aspects of intra-articular injection therapies for osteoarthritis. METHODS: A committee of 10 experts from Italian universities, public hospitals, territorial services, research institutes and patient associations was set up. Fifty-two clinicians from a large number of Italian medical centers specialized in intra-articular injection therapy took part in a Delphi process aimed at obtaining consensus statements among the participants. RESULTS: Large consensus was obtained for statements grouped under the following main themes: treatment indications; drug/medical device choice; treatment efficacy; and appropriate setting. CONCLUSIONS: The consensus statements developed by a large number of experts may be used as a practical reference tool to help physicians treat osteoarthritis patients by means of intra-articular injection therapies.

  9. Blind Cartography for Side Channel Attacks: Cross-Correlation Cartography

    Directory of Open Access Journals (Sweden)

    Laurent Sauvage

    2012-01-01

    Full Text Available Side channel and fault injection attacks are major threats to cryptographic applications of embedded systems. Best performances for these attacks are achieved by focusing sensors or injectors on the sensible parts of the application, by means of dedicated methods to localise them. Few methods have been proposed in the past, and all of them aim at pinpointing the cryptoprocessor. However it could be interesting to exploit the activity of other parts of the application, in order to increase the attack's efficiency or to bypass its countermeasures. In this paper, we present a localisation method based on cross-correlation, which issues a list of areas of interest within the attacked device. It realizes an exhaustive analysis, since it may localise any module of the device, and not only those which perform cryptographic operations. Moreover, it also does not require a preliminary knowledge about the implementation, whereas some previous cartography methods require that the attacker could choose the cryptoprocessor inputs, which is not always possible. The method is experimentally validated using observations of the electromagnetic near field distribution over a Xilinx Virtex 5 FPGA. The matching between areas of interest and the application layout in the FPGA floorplan is confirmed by correlation analysis.

  10. The effects of intratendinous and retrocalcaneal intrabursal injections of corticosteroid on the biomechanical properties of rabbit Achilles tendons.

    Science.gov (United States)

    Hugate, Ronald; Pennypacker, Jason; Saunders, Marnie; Juliano, Paul

    2004-04-01

    The use of corticosteroid injections in the treatment of retrocalcaneal bursitis is controversial. We assessed the effects of corticosteroid injections, both within the tendon substance and into the retrocalcaneal bursa, on the biomechanical properties of rabbit Achilles tendons. The systemic effects of bilateral corticosteroid injections were also studied. The rabbits were divided into three treatment groups. The rabbits in Group I received injections of corticosteroid into the Achilles tendon on the left side and injections of normal saline solution into the Achilles tendon on the right, those in Group II received injections of corticosteroid into the retrocalcaneal bursa on the left side and injections of saline solution into the Achilles tendon on the right, and those in Group III received injections of corticosteroid into the Achilles tendon on the left side and injections of corticosteroid into the retrocalcaneal bursa on the right. These injections were given weekly for three weeks. At four weeks after the final injection, the tendons were harvested and were tested biomechanically to determine failure load, midsubstance strain and total strain, modulus of elasticity, failure stress, and total energy absorbed. The site of failure was also documented. The groups were compared according to the location of the injections, the type of injection (steroid or saline solution), and the total systemic load of steroid. Specimens from limbs that had received intratendinous injections of corticosteroid showed significantly decreased failure stress compared with those from limbs that had received intratendinous injections of saline solution (p = 0.008). Specimens from limbs that had received intrabursal injections of corticosteroid demonstrated significantly decreased failure stress (p = 0.05), significantly decreased total energy absorbed (p = 0.017), and significantly increased total strain (p = 0.049) compared with specimens from limbs that had received intratendinous

  11. Surviving in two worlds: social and structural violence of Thai female injecting drug users.

    Science.gov (United States)

    Haritavorn, Niphattra

    2014-01-01

    Thai females injecting drugs are ensnared in a web of problems arising from forms of prejudice that magnify their vulnerability. They are vulnerable, at risk, and exposed to a high degree of social suffering. This paper aims to elucidate how social production and structural violence combine to shape the lives of these women. Using a qualitative methodology, two focus groups with 5 key informants and in-depth interviews involving a total of 35 women injecting drugs were conducted in Bangkok. The findings reveal that the structural environment that directly impacts upon these women's lives becomes the reason for their suffering. The structural environment puts these women at risk of violence in numerous social settings in which these women engage as well as generating tension at a subjective level (i.e. the habitus) of these women. Thai female injecting drug users are trapped in a difficult tension between the demands for being Thai women seeking to exist in the masculine world of drug use but at the same time meeting Thai society's expectations of womanhood. Unequal gender relations are manifest in the everyday violence that women face in the drug community, culminating in the essential nature of women being questioned, undermined and threatened. Living in the drug community, women are subjected to violence and harassment, and gendered brutality by intimate partners. In conclusion, the social suffering that Thai female injecting drug users find themselves confronting is confined to dilemmas cause by tensions between drug use and the overriding gender habitus. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    International Nuclear Information System (INIS)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-01-01

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10 -5 to 0.26 μg ml -1 for calf thymus DNA and 5.0x10 -8 to 5.0x10 -5 μg ml -1 for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3σ) are 6.5x10 -6 μg ml -1 for calf thymus DNA and 4.3x10 -8 μg ml -1 for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed

  13. Toxicological study of DTPA as a drug, (4). Effect of intravenously injected DTPA on cardiovascular system in beagle dogs

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Satoshi; Iida, Haruzo

    1988-09-01

    We have previously reported that the side effects on cardiovascular system such as the heart failure, increases of blood pressure and pulse accompanied with hypocalcemia occurred in rats when Zn-DTPA was injected intravenously, but those did not occur by Ca-DTPA. This is in the reverse that it is generally said that Zn-DTPA is more safe than Ca-DTPA. This study was carried out to examine whether the same side effects occurred in different animal species or not. Zn-DTPA or Ca-DTPA (30, 150, 300 and 600 ..mu..mol/kg) was injected intravenously to beagle dogs. The hypocalcemia was observed in the dogs by Zn-DTPA injection, but it was not by Ca-DTPA. After Zn-DTPA injection, the increase of blood pressure and pulse, and heart failure was observed in 3 out of 5 dogs at 300 ..mu..mol/kg dose, and in 3 out of 8 dogs at 600 ..mu..mol/kg dose. These changes were the same degrees as those in rats. In the present study, it is suggested that the side effects induced by Zn-DTPA intravenous injection occur independently of animal species and the data obtained from animal experiments can be available to estimate DTPA toxicity in humans.

  14. Recurrent Bacteremia, a Complication of Cyanoacrylate Injection for Variceal Bleeding: Report of Two Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    T. Galperine

    2009-01-01

    Full Text Available We report the first description of recurrent bacteremia in two patients after cyanoacrylate injection for gastric varices bleeding treated with antibiotics alone. Adapted and prolonged antibiotic treatment allowed a complete resolution of the infection with no relapse after more than 6 months. According to recent data, prophylactic antibiotics should be further investigated for patients with bleeding varices undergoing cyanoacrylate injection.

  15. A Design Method for the Tension Side of Statically Loaded, Bolted Beam-to-Column Connections

    NARCIS (Netherlands)

    Zoetemeijer, P.

    1974-01-01

    In this paper a design method for the tension side of statically loaded, bolted beam-to-column connections is developed based on the plastic behaviour of the flanges and the bolts under the assumption that the plastification is large enough to allow the adoption of the most favourable static

  16. Multiobjective Design of Turbo Injection Mode for Axial Flux Motor in Plastic Injection Molding Machine by Particle Swarm Optimization

    Directory of Open Access Journals (Sweden)

    Jian-Long Kuo

    2015-01-01

    Full Text Available This paper proposes a turbo injection mode (TIM for an axial flux motor to apply onto injection molding machine. Since the injection molding machine requires different speed and force parameters setting when finishing a complete injection process. The interleaved winding structure in the motor provides two different injection levels to provide enough injection forces. Two wye-wye windings are designed to switch two control modes conveniently. Wye-wye configuration is used to switch two force levels for the motor. When only one set of wye-winding is energized, field weakening function is achieved. Both of the torque and speed increase under field weakening operation. To achieve two control objectives for torque and speed of the motor, fuzzy based multiple performance characteristics index (MPCI with particle swarm optimization (PSO is used to find out the multiobjective optimal design solution. Both of the torque and speed are expected to be maximal at the same time. Three control factors are selected as studied factors: winding diameter, winding type, and air-gap. Experimental results show that both of the torque and speed increase under the optimal condition. This will provide enough large torque and speed to perform the turbo injection mode in injection process for the injection molding machine.

  17. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    Science.gov (United States)

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  18. Computer-mediated communication as a channel for social resistance : The strategic side of SIDE

    NARCIS (Netherlands)

    Spears, R; Lea, M; Corneliussen, RA; Postmes, T; Ter Haar, W

    2002-01-01

    In two studies, the authors tested predictions derived from the social identity model of deindividuation effects (SIDE) concerning the potential of computer-mediated communication (CMC) to serve as a means to resist powerful out-groups. Earlier research using the SIDE model indicates that the

  19. An Effective Surface Modeling Method for Car Styling from a Side-View Image

    Institute of Scientific and Technical Information of China (English)

    LIBao-jun; ZHANGXue-fang; LVZhang-quan; QIYi-chao

    2014-01-01

    We introduce an almost-automatic technique for generating 3D car styling surface models based on a single side-view image. Our approach combines the prior knowledge of car styling and deformable curve network model to obtain an automatic modeling process. Firstly, we define the consistent parameterized curve template for 2D and 3D case respectivelyby analyzingthe characteristic lines for car styling. Then, a semi-automatic extraction from a side-view car image is adopted. Thirdly, statistic morphable model of 3D curve network isused to get the initial solution with sparse point constraints.Withonly afew post-processing operations, the optimized curve network models for creating surfaces are obtained. Finally, the styling surfaces are automatically generated using template-based parametric surface modeling method. More than 50 3D curve network models are constructed as the morphable database. We show that this intelligent modeling toolsimplifiesthe exhausted modeling task, and also demonstratemeaningful results of our approach.

  20. A low-voltage flash memory cell utilizing the gate-injection program/erase method with a recessed channel structure

    International Nuclear Information System (INIS)

    Wu Dake; Huang Ru; Wang Pengfei; Tang Poren; Wang Yangyuan

    2008-01-01

    In this paper, a low-voltage recessed channel SONOS flash memory using the gate-injection program/erase method is proposed and investigated for NAND application. It is shown that the proposed flash memory can achieve 8 V lower programming voltage compared with planar flash memory, due to the effective capacitance coupling and the electric-field enhancement by combining the recessed channel structure and the gate-injection program/erase method. In addition, more than 30% larger threshold voltage window and improved short channel effects can be obtained in the proposed flash memory

  1. Study on flow-induced acoustic resonance in symmetrically located side-branches using dynamic PIV technique

    International Nuclear Information System (INIS)

    Li, Yanrong; Inagaki, Terumi; Nishi, Yasuyuki; Someya, Satoshi; Okamoto, Koji

    2014-01-01

    Flow-induced acoustic resonance in a piping system containing closed coaxial side-branches was investigated experimentally. Resonance characteristics of the piping system were examined by a microphone. The results revealed that the resonance frequencies of the shear layer instability were locked in corresponding to the natural frequencies of the side-branches. Phase-averaged velocity fields were obtained two-dimensionally in the junction of coaxial side-branches by dynamic particle image velocimetry (PIV), while the acoustic resonance was induced at the first and second hydrodynamic modes. Patterns of jet correspond to two hydrodynamic modes were derived from the phase-averaged velocity fields. The dynamic PIV can acquire time-series velocity fluctuations, then, two-dimensional phase delay maps under resonance and off-resonance conditions in the junction of coaxial side-branches were obtained. Experimental results show that the proposed phase delay map method costs less experiment and computation time and achieves a better accuracy and repetition than the phase-locking technique. In addition, the phase delay map method can obtain phase difference under the different frequency components. This is important when two different acoustic modes were induced in one experimental condition. (author)

  2. Using standardized methods for research on HIV and injecting drug use in developing/transitional countries: case study from the WHO Drug Injection Study Phase II

    Directory of Open Access Journals (Sweden)

    Stimson Gerry V

    2006-03-01

    Full Text Available Abstract Background Successful cross-national research requires methods that are both standardized across sites and adaptable to local conditions. We report on the development and implementation of the methodology underlying the survey component of the WHO Drug Injection Study Phase II – a multi-site study of risk behavior and HIV seroprevalence among Injecting Drug Users (IDUs. Methods Standardized operational guidelines were developed by the Survey Coordinating Center in collaboration with the WHO Project Officer and participating site Investigators. Throughout the duration of the study, survey implementation at the local level was monitored by the Coordinating Center. Surveys were conducted in 12 different cities. Prior rapid assessment conducted in 10 cities provided insight into local context and guided survey implementation. Where possible, subjects were recruited both from drug abuse treatment centers and via street outreach. While emphasis was on IDUs, non-injectors were also recruited in cities with substantial non-injecting use of injectable drugs. A structured interview and HIV counseling/testing were administered. Results Over 5,000 subjects were recruited. Subjects were recruited from both drug treatment and street outreach in 10 cities. Non-injectors were recruited in nine cities. Prior rapid assessment identified suitable recruitment areas, reduced drug users' distrust of survey staff, and revealed site-specific risk behaviors. Centralized survey coordination facilitated local questionnaire modification within a core structure, standardized data collection protocols, uniform database structure, and cross-site analyses. Major site-specific problems included: questionnaire translation difficulties; locating affordable HIV-testing facilities; recruitment from drug treatment due to limited/selective treatment infrastructure; access to specific sub-groups of drug users in the community, particularly females or higher income groups

  3. An image-based method for objectively assessing injection moulded plastic quality

    DEFF Research Database (Denmark)

    Hannemose, Morten; Nielsen, Jannik Boll; Zsíros, László

    2017-01-01

    In high volume productions based on casting processes, like high-pressure die casting (HPDC) or injection moulding, there is a wide range of variables that affect the end quality of produced parts. These variables include production parameters (temperature, pressure, mixture), and external factors...... (humidity, temperature, etc.). With this many variables it is a challenge to maintain a stable output quality, wherefore massive amounts of resources are spent on quality assurance (QA) of produced parts. Currently, this QA is done manually through visual inspection. We demonstrate how a multispectral...... imaging system can be used to automatically rate the quality of a produced part using an autocorrelation and a Fourier-based method. These methods are compared with human rankings and achieve good correlations on a variety of samples....

  4. The anterior approach for a non-image-guided intra-articular hip injection.

    Science.gov (United States)

    Mei-Dan, Omer; McConkey, Mark O; Petersen, Brian; McCarty, Eric; Moreira, Brett; Young, David A

    2013-06-01

    The purpose of this study was to investigate and validate the accuracy and safety of a technique using an anterior approach for non-image-guided intra-articular injection of the hip by use of anatomic landmarks. We enrolled 55 patients. Injections were performed before supine hip arthroscopy after landmarking and before application of traction. After the needle insertion, success was confirmed with an air arthrogram and by direct visualization after arthroscope insertion. Accuracy and difficulty achieving correct needle placement were correlated with age, weight, height, body mass index, body type, gender, and surgical indication, as well as femoral and pelvic morphology. Forty-five patients who underwent injection in the office were followed up separately to document injection side effects. Needle placement accuracy was correlated to patients' demographics. All statistical tests with P values were 2 sided, with the level of significance set at P injections by use of the direct anterior approach, from the intersection of the lines drawn from the anterior superior iliac spine and 1 cm distal to the tip of the greater trochanter, are safe and reproducible. Patient characteristics, such as increased subcutaneous adipose tissue or osseous anatomic variants, can lead to difficulty in placing the needle successfully. These characteristics can be predicted with the aid of physical examination and careful study of the pelvic radiographs. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. [Cutaneous atrophy and hypopigmentation secondary to intra-articular corticosteroid injection].

    Science.gov (United States)

    Loarte Pasquel, E P; Cabal García, A A

    2014-04-01

    Epicondylitis is the most common disease of the elbow. It is a tendinitis caused, in most cases, by repetitive motion of the forearm extensor muscles, and belongs to the group of occupational diseases that are related to work activity or sport. Intra-articular injections of glucocorticoids are often used by dermatologists, rheumatologists, orthopaedic surgeons, and primary care due to their ease of administration. However, this procedure has potential side effects. There are a limited number of case reports describing atrophy and hypopigmentation of the skin as a side effect. The general indications for glucocorticoid injections are monofocal and multifocal inflammatory disease, multifocal articular or soft tissue disease. It is more often used in more severe monofocal or multifocal inflammation, failure of drug treatment and/or rehabilitatory when other treatments are contraindicated. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  6. Factors affecting the toxicity of methylmercury injected into eggs

    Science.gov (United States)

    Heinz, G.H.; Hoffman, D.J.; Kondrad, S.L.; Erwin, C.A.

    2006-01-01

    . In addition, some species of bird eggs require incubation on their sides with the eggs being rolled 180? for them to develop normally. Therefore, we adopted a procedure of incubating the eggs of all species on their sides and rolling them 180? every hour. Little has been published about the conditions of temperature, humidity, and the movements to which eggs of wild birds need to be subjected for them to hatch optimally under artificial incubation. Not unexpectedly, hatching success in an artificial incubator is generally less than what natural incubation by the parents can achieve. However, the survival of control embryos of most wild bird species was good (generally > 80%) up to within 1 or 2 days of hatching when we incubated the eggs at 37.5?C (or 37.6?C for gallinaceous species) at a relative humidity that resulted in an approximate 15% to 16% loss in egg weight by the end of incubation and by incubating the eggs on their sides and rolling them 180?/h. To improve statistical comparisons, we used survival through 90% of incubation as our measurement to compare survival of controls with survival of eggs injected with graded concentrations of mercury.

  7. Supply-side and demand-side policies for biosimilars: an overview in 10 European member states

    OpenAIRE

    R?muzat, C?cile; Kapu?niak, Anna; Caban, Aleksandra; Ionescu, Dan; Radi?re, Guerric; Mendoza, Cyril; Toumi, Mondher

    2017-01-01

    ABSTRACT Objective: This study aimed to provide an overview of biosimilar?policies in 10 EU MSs. Methods: Ten EU MS pharmaceutical markets (Belgium, France, Germany, Greece, Hungary, Italy, Poland, Spain, Sweden, and the UK) were selected. A comprehensive literature review?was performed to identify supply-side and demand-side policies in place in the selected countries. Results: Supply-side policies for biosimilars commonly include price linkage, price re-evaluation, and tendering; the use of...

  8. Hair loss at injection sites of mesotherapy for alopecia.

    Science.gov (United States)

    El-Komy, Mohamed; Hassan, Akmal; Tawdy, Amira; Solimon, Mohamed; Hady, Mohamed Abdel

    2017-12-01

    The side effects of mesotherapy for treatment of various forms of alopecia are often underreported, while scientific data for its efficacy are severely lacking. To demonstrate the late onset side effects of mesotherapy for alopecia. Three patients with androgenetic alopecia showed hair loss after previously uneventful mesotherapy sessions up to 1 year. Clinical, dermoscopic, and histopathological findings suggested an inflammatory scaring process at sites of mesotherapy injections. Mesotherapy for androgenetic alopecia may paradoxically induce hair loss and scarring. Proper regulation and monitoring of the use of mesotherapy products for treating hair loss in women, needs to be addressed. © 2017 Wiley Periodicals, Inc.

  9. Chemiluminescence determination of ultramicro DNA with a flow-injection method

    Energy Technology Data Exchange (ETDEWEB)

    Chen Hui; Zhou Min; Jin Xiaoyong; Song Yumin; Zhang Ziyu; Ma Yongjun

    2002-02-12

    A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6x10{sup -5} to 0.26 {mu}g ml{sup -1} for calf thymus DNA and 5.0x10{sup -8} to 5.0x10{sup -5} {mu}g ml{sup -1} for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3{sigma}) are 6.5x10{sup -6} {mu}g ml{sup -1} for calf thymus DNA and 4.3x10{sup -8} {mu}g ml{sup -1} for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed.

  10. Double-sided anodic titania nanotube arrays: a lopsided growth process.

    Science.gov (United States)

    Sun, Lidong; Zhang, Sam; Sun, Xiao Wei; Wang, Xiaoyan; Cai, Yanli

    2010-12-07

    In the past decade, the pore diameter of anodic titania nanotubes was reported to be influenced by a number of factors in organic electrolyte, for example, applied potential, working distance, water content, and temperature. All these were closely related to potential drop in the organic electrolyte. In this work, the essential role of electric field originating from the potential drop was directly revealed for the first time using a simple two-electrode anodizing method. Anodic titania nanotube arrays were grown simultaneously at both sides of a titanium foil, with tube length being longer at the front side than that at the back side. This lopsided growth was attributed to the higher ionic flux induced by electric field at the front side. Accordingly, the nanotube length was further tailored to be comparable at both sides by modulating the electric field. These results are promising to be used in parallel configuration dye-sensitized solar cells, water splitting, and gas sensors, as a result of high surface area produced by the double-sided architecture.

  11. SUNCT syndrome. Two cases in Argentina.

    Science.gov (United States)

    Raimondi, E; Gardella, L

    1998-05-01

    Two patients suffering from SUNCT syndrome are presented. Some features are remarkable. The first patient was a 69-year-old man whose first crisis was located in the right supraorbital region. After a 4-month spontaneous remission, the pain returned to the upper part of the cheek, radiating to the supraciliary region on the same side, with lacrimation and conjunctival injection. Rhinorrhea was absent. The painful attacks were triggered by head movements. Clinical improvement occurred with carbamazepine treatment. The second patient was a 48-year-old woman whose painful attacks lasted from 30 to 45 seconds followed by a burning sensation lasting 2 hours. Autonomic signs such as conjunctival injection, lacrimation, and edema and ipsilateral ptosis of the upper lid were rather marked. There was never any rhinorrhea. Her attacks were triggered by head and eye movements. She responded to the administration of corticosteroids and carbamazepine. According to these features, the two patients had SUNCT syndrome, and the positive carbamazepine response suggests a relationship with trigeminal neuralgia.

  12. Optimization of air injection parameters toward optimum fuel saving effect for ships

    Science.gov (United States)

    Lee, Inwon; Park, Seong Hyeon

    2016-11-01

    Air lubrication method is the most promising commercial strategy for the frictional drag reduction of ocean going vessels. Air bubbles are injected through the array of holes or the slots installed onto the flat bottom surface of vessel and a sufficient supply of air is required to ensure the formation of stable air layer by the by the coalescence of the bubbles. The air layer drag reduction becomes economically meaningful when the power gain through the drag reduction exceeds the pumping power consumption. In this study, a model ship of 50k medium range tanker is employed to investigate air lubrication method. The experiments were conducted in the 100m long towing tank facility at the Pusan National University. To create the effective air lubrication with lower air flow rate, various configurations including the layout of injection holes, employment of side fences and static trim have been tested. In the preliminary series of model tests, the maximum 18.13%(at 15kts) of reduction of model resistance was achieved. This research was supported by the National Research Foundation of Korea (NRF) Grant funded by the Korea government (MEST) through GCRC-SOP (Grant No. 2011-0030013).

  13. Development of a sequential injection-square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode.

    Science.gov (United States)

    dos Santos, Luciana B O; Infante, Carlos M C; Masini, Jorge C

    2010-03-01

    This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): i(p) = (-20.5 ± 0.3)C (paraquat) - (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.

  14. Efficacy and safety of collagenase Clostridium histolyticum injection for Dupuytren contracture: report of 40 cases.

    Science.gov (United States)

    Alberton, F; Corain, M; Garofano, A; Pangallo, L; Valore, A; Zanella, V; Adani, R

    2014-12-01

    Dupuytren's disease (DD) is a fibroproliferative pathology that affects the palmar aponeurosis causing the development of nodules and collagen cords and the progressive flexion of the fingers. The standard procedure is surgical fasciectomy, followed by high recurrence rates. Collagenase Clostridium histolyticum (CCH) injection represents an innovative noninvasive approach to the treatment of DD. This prospective study was designed to examine the efficacy and safety of CCH injection performed in the outpatient, using local anesthesia. Forty patients [32 metacarpophalangeal (MP), 8 proximal interphalangeal (PIP)] with Dupuytren's contracture of at least 20° for MP joint and any degree for PIP joint were included. The mean age was 66. All joints were treated with a single vial of collagenase injection and manual breaking of the cord 24 h after. All adverse effects (AEs) were monitored. Patients were checked 7, 30, 90, and 180 days after the injection. Primary endpoint was a reduction in digit contracture within 0°-5° of normal extension. Secondary endpoints were the improvement of range of motion, the evaluation of AEs incidence, and cost-effectiveness of collagenase treatment. About 67.5 % of patients obtained a clinical success. At 6 months, a further 7.5% attained the same result. The mean contracture of treated joints was 5.3º for MP and 6.8° for PIP joints. Twenty-three patients had one or more mild-to-moderate side effects. The use of collagenase appears to be an effective and safe method for the treatment of Dupuytren's contracture. Therapeutic success was achieved in a significant percentage of patients. The incidence of side effects was higher, but they were local reactions of short duration. The use of a single collagenase vial in patients treated in day surgery appears more cost-effective than surgery.

  15. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    International Nuclear Information System (INIS)

    Mesquita, Raquel B.R.; Ferreira, M. Teresa S.O.B.; Toth, Ildiko V.; Bordalo, Adriano A.; McKelvie, Ian D.; Rangel, Antonio O.S.S.

    2011-01-01

    Highlights: → Sequential injection determination of phosphate in estuarine and freshwaters. → Alternative spectrophotometric flow cells are compared. → Minimization of schlieren effect was assessed. → Proposed method can cope with wide salinity ranges. → Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 μM PO 4 3- ) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 μM) was achieved using both detection systems.

  16. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Raquel B.R. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); Ferreira, M. Teresa S.O.B. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Toth, Ildiko V. [REQUIMTE, Departamento de Quimica, Faculdade de Farmacia, Universidade de Porto, Rua Anibal Cunha, 164, 4050-047 Porto (Portugal); Bordalo, Adriano A. [Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); McKelvie, Ian D. [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); Rangel, Antonio O.S.S., E-mail: aorangel@esb.ucp.pt [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)

    2011-09-02

    Highlights: {yields} Sequential injection determination of phosphate in estuarine and freshwaters. {yields} Alternative spectrophotometric flow cells are compared. {yields} Minimization of schlieren effect was assessed. {yields} Proposed method can cope with wide salinity ranges. {yields} Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 {mu}M PO{sub 4}{sup 3-}) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 {mu}M) was achieved using both detection systems.

  17. [Promising new injection method to prevent angialgia/phlebitis from epirubicin hydrochloride therapy for breast cancer].

    Science.gov (United States)

    Ono, Chiemi; Yamagami, Mitsue; Kamatani, Rika; Yamamoto, Makoto; Mukouyama, Tomoya; Sugimoto, Masakazu; Suzuki, Taizan; Kamo, Nobuyuki; Seki, Nobuhiko; Eguchi, Kenji; Ikeda, Tadashi

    2012-05-01

    Epirubicin hydrochloride(EPI)is well known to cause phlebitis as a typical adverse drug reaction. By preventing the development of severe phlebitis, patients are expected to continue effective chemotherapy with EPI without a decrease in QOL. We have previously reported promising results of a new injection method to prevent phlebitis from occurring during EPI therapy thorough a prospective clinical trial in our hospital(Jpn J Cancer Chemother 36: 969-974, 2009). In the present study, we have compared the conventional injection method(EPI main -route method, n=15)with our new method, which has been consistently practiced at present(EPI sub -route method, n=77). We found that in the EPI main -route method, angialgia/phlebitis developed in 14 of 15 cases(Grade 3, 53. 3%), leading to alteration of the regimen in 3 cases. On the other hand, with the EPI sub -route method, incidence of angialgia/phlebitis was markedly decreased, and only 6 of 77 cases developed these adverse reactions(Grade 3, 0%). One possible explanation for these results is that the reduction of intimal stimulation by the EPI sub -route method might be caused by the dilution and washout of EPI with pre-medication, as well as the shortened infusion times of EPI. Therefore, on the basis of the above hypothesis, we conclude that the EPI sub-route method might be a more effective treatment for the expected prevention of angialgia/phlebitis.

  18. Periodontal ligament and intraosseous anesthetic injection techniques: alternatives to mandibular nerve blocks.

    Science.gov (United States)

    Moore, Paul A; Cuddy, Michael A; Cooke, Matthew R; Sokolowski, Chester J

    2011-09-01

    and Overview. The provision of mandibular anesthesia traditionally has relied on nerve block anesthetic techniques such as the Halsted, the Gow-Gates and the Akinosi-Vazirani methods. The authors present two alternative techniques to provide local anesthesia in mandibular teeth: the periodontal ligament (PDL) injection and the intraosseous (IO) injection. The authors also present indications for and complications associated with these techniques. The PDL injection and the IO injection are effective anesthetic techniques for managing nerve block failures and for providing localized anesthesia in the mandible. Dentists may find these techniques to be useful alternatives to nerve block anesthesia.

  19. DarkSide-20k: A 20 tonne two-phase LAr TPC for direct dark matter detection at LNGS

    Science.gov (United States)

    Aalseth, C. E.; Acerbi, F.; Agnes, P.; Albuquerque, I. F. M.; Alexander, T.; Alici, A.; Alton, A. K.; Antonioli, P.; Arcelli, S.; Ardito, R.; Arnquist, I. J.; Asner, D. M.; Ave, M.; Back, H. O.; Barrado Olmedo, A. I.; Batignani, G.; Bertoldo, E.; Bettarini, S.; Bisogni, M. G.; Bocci, V.; Bondar, A.; Bonfini, G.; Bonivento, W.; Bossa, M.; Bottino, B.; Boulay, M.; Bunker, R.; Bussino, S.; Buzulutskov, A.; Cadeddu, M.; Cadoni, M.; Caminata, A.; Canci, N.; Candela, A.; Cantini, C.; Caravati, M.; Cariello, M.; Carlini, M.; Carpinelli, M.; Castellani, A.; Catalanotti, S.; Cataudella, V.; Cavalcante, P.; Cavuoti, S.; Cereseto, R.; Chepurnov, A.; Cicalò, C.; Cifarelli, L.; Citterio, M.; Cocco, A. G.; Colocci, M.; Corgiolu, S.; Covone, G.; Crivelli, P.; D'Antone, I.; D'Incecco, M.; D'Urso, D.; Da Rocha Rolo, M. D.; Daniel, M.; Davini, S.; de Candia, A.; De Cecco, S.; De Deo, M.; De Filippis, G.; De Guido, G.; De Rosa, G.; Dellacasa, G.; Della Valle, M.; Demontis, P.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Dionisi, C.; Dolgov, A.; Dormia, I.; Dussoni, S.; Empl, A.; Fernandez Diaz, M.; Ferri, A.; Filip, C.; Fiorillo, G.; Fomenko, K.; Franco, D.; Froudakis, G. E.; Gabriele, F.; Gabrieli, A.; Galbiati, C.; Garcia Abia, P.; Gendotti, A.; Ghisi, A.; Giagu, S.; Giampa, P.; Gibertoni, G.; Giganti, C.; Giorgi, M. A.; Giovanetti, G. K.; Gligan, M. L.; Gola, A.; Gorchakov, O.; Goretti, A. M.; Granato, F.; Grassi, M.; Grate, J. W.; Grigoriev, G. Y.; Gromov, M.; Guan, M.; Guerra, M. B. B.; Guerzoni, M.; Gulino, M.; Haaland, R. K.; Hallin, A.; Harrop, B.; Hoppe, E. W.; Horikawa, S.; Hosseini, B.; Hughes, D.; Humble, P.; Hungerford, E. V.; Ianni, An.; Jillings, C.; Johnson, T. N.; Keeter, K.; Kendziora, C. L.; Kim, S.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Kuss, M.; Kuźniak, M.; La Commara, M.; Lehnert, B.; Li, X.; Lissia, M.; Lodi, G. U.; Loer, B.; Longo, G.; Loverre, P.; Lussana, R.; Luzzi, L.; Ma, Y.; Machado, A. A.; Machulin, I. N.; Mandarano, A.; Mapelli, L.; Marcante, M.; Margotti, A.; Mari, S. M.; Mariani, M.; Maricic, J.; Martoff, C. J.; Mascia, M.; Mayer, M.; McDonald, A. B.; Messina, A.; Meyers, P. D.; Milincic, R.; Moggi, A.; Moioli, S.; Monroe, J.; Monte, A.; Morrocchi, M.; Mount, B. J.; Mu, W.; Muratova, V. N.; Murphy, S.; Musico, P.; Nania, R.; Navrer Agasson, A.; Nikulin, I.; Nosov, V.; Nozdrina, A. O.; Nurakhov, N. N.; Oleinik, A.; Oleynikov, V.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Palmas, S.; Pandola, L.; Pantic, E.; Paoloni, E.; Paternoster, G.; Pavletcov, V.; Pazzona, F.; Peeters, S.; Pelczar, K.; Pellegrini, L. A.; Pelliccia, N.; Perotti, F.; Perruzza, R.; Pesudo, V.; Piemonte, C.; Pilo, F.; Pocar, A.; Pollmann, T.; Portaluppi, D.; Pugachev, D. A.; Qian, H.; Radics, B.; Raffaelli, F.; Ragusa, F.; Razeti, M.; Razeto, A.; Regazzoni, V.; Regenfus, C.; Reinhold, B.; Renshaw, A. L.; Rescigno, M.; Retière, F.; Riffard, Q.; Rivetti, A.; Rizzardini, S.; Romani, A.; Romero, L.; Rossi, B.; Rossi, N.; Rubbia, A.; Sablone, D.; Salatino, P.; Samoylov, O.; Sánchez García, E.; Sands, W.; Sanfilippo, S.; Sant, M.; Santorelli, R.; Savarese, C.; Scapparone, E.; Schlitzer, B.; Scioli, G.; Segreto, E.; Seifert, A.; Semenov, D. A.; Shchagin, A.; Shekhtman, L.; Shemyakina, E.; Sheshukov, A.; Simeone, M.; Singh, P. N.; Skensved, P.; Skorokhvatov, M. D.; Smirnov, O.; Sobrero, G.; Sokolov, A.; Sotnikov, A.; Speziale, F.; Stainforth, R.; Stanford, C.; Suffritti, G. B.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Tonazzo, A.; Tosi, A.; Trinchese, P.; Unzhakov, E. V.; Vacca, A.; Vázquez-Jáuregui, E.; Verducci, M.; Viant, T.; Villa, F.; Vishneva, A.; Vogelaar, B.; Wada, M.; Wahl, J.; Walding, J.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Williams, R.; Wojcik, M. M.; Wu, S.; Xiang, X.; Xiao, X.; Yang, C.; Ye, Z.; Yllera de Llano, A.; Zappa, F.; Zappalà, G.; Zhu, C.; Zichichi, A.; Zullo, M.; Zullo, A.; Zuzel, G.

    2018-03-01

    Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LAr TPC) with an active (fiducial) mass of 23 t (20 t). This paper describes a preliminary design for the experiment, in which the DarkSide-20k LAr TPC is deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). This preliminary design provides a baseline for the experiment to achieve its physics goals, while further development work will lead to the final optimization of the detector parameters and an eventual technical design. Operation of DarkSide-50 demonstrated a major reduction in the dominant 39Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of >3 × 109 is achievable. This, along with the use of the veto system and utilizing silicon photomultipliers in the LAr TPC, are the keys to unlocking the path to large LAr TPC detector masses, while maintaining an experiment in which less than < 0.1 events (other than ν-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ, giving sensitivity to WIMP-nucleon cross sections of 1.2 × 10^{-47} cm2 (1.1 × 10^{-46} cm2) for WIMPs of 1 TeV/c 2 (10 TeV/c 2) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background.

  20. Side effects affected my daily activities a lot”: a qualitative exploration of the impact of contraceptive side effects in Bangladesh

    Directory of Open Access Journals (Sweden)

    Jain A

    2017-07-01

    Full Text Available Aparna Jain,1 Laura Reichenbach,1 Iqbal Ehsan,2 Ubaidur Rob2 1Evidence Project, Population Council, Washington, DC, USA; 2Evidence Project, Population Council, Dhaka, Bangladesh Purpose: In a country like Bangladesh that has made great progress in contraceptive use with one of the lowest levels of fertility and highest levels of contraceptive use, understanding what factors influence women’s decisions to discontinue a contraceptive method and not switch to a new method is critical in designing interventions and programs that will help enable Bangladesh to reach its FP2020 goals. Research on side effects has focused on physical manifestations like headaches, moodiness, abdominal pain, and menstrual irregularities. While physical effects alone may stop women from continuing a contraceptive method, less is known about how side effects influence women’s daily activities and lives. The purpose of this study is to understand the ways that side effects affect Bangladeshi women’s participation in different social settings.Methods: Thirty-five in-depth interviews with married women who recently discontinued or switched to a different contraceptive method were conducted in Sylhet and Khulna Divisions. Interviews explored reasons for discontinuation including experience of side effects and impact of side effects on women’s lives.Results: Key themes emerged including that side effects are not only experienced physically but are barriers to women’s participation in many aspects of their lives. The spheres of life that most commonly appeared to be influenced by side effects include religion, household, and sexual intimacy irrespective of method used or residence.Conclusion: Family planning providers need to be aware of these additional consequences associated with contraceptive side effects to provide tailored counseling that recognizes these issues and helps women to mitigate them. For Bangladesh to achieve its FP2020 goals, understanding the

  1. Anesthetic efficacy of a repeated intraosseous injection given 30 min following an inferior alveolar nerve block/intraosseous injection.

    OpenAIRE

    Reitz, J.; Reader, A.; Nist, R.; Beck, M.; Meyers, W. J.

    1998-01-01

    To determine whether a repeated intraosseous (IO) injection would increase or prolong pulpal anesthesia, we measured the degree of anesthesia obtained by a repeated IO injection given 30 min following a combination inferior alveolar nerve block/intraosseous injection (IAN/IO) in mandibular second premolars and in first and second molars. Using a repeated-measures design, we randomly assigned 38 subjects to receive two combinations of injections at two separate appointments. The combinations w...

  2. Water injection profiling

    International Nuclear Information System (INIS)

    Arnold, D.M.

    1982-01-01

    A method of neutron-gamma logging is described, in which water, injected in a cased well borehole with peforations, is irradiated with neutrons of 10 MeV or greater, and subsequent gamma radiation is detected by a pair of detectors along the borehole. Counting rates of detectors are analyzed in terms of two gamma ray energy windows. Linear flow velocity of fluid moving downward within the casing is used in conjunction with count rate data to determine volume flow rates of water moving in other directions. Apparatus includes a sonde with a neutron source and appropriate gamma sensors

  3. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  4. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    Science.gov (United States)

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  5. WGA-Alexa transsynaptic labeling in the phrenic motor system of adult rats: Intrapleural injection versus intradiaphragmatic injection.

    Science.gov (United States)

    Buttry, Janelle L; Goshgarian, Harry G

    2015-02-15

    Intrapleural injection of CTB-Alexa 488, a retrograde tracer, provides an alternative labeling technique to the surgically invasive laparotomy required for intradiaphragmatic injection. However, CTB-Alexa 488 is incapable of crossing synapses restricting the tracer to the phrenic nuclei and the intercostal motor nuclei in the spinal cord. Intrapleural injection of WGA-Alexa 488, a transsynaptic tracer, provides a method to label the respiratory motor pathway in both the spinal cord and medulla. Intradiaphragmatic injection of WGA-Alexa 594 and vagal nerve injections of True blue were used to confirm the phrenic nuclei and to differentiate between the rVRG and the NA in the medulla. Following intrapleural injection, WGA-Alexa 488 was retrogradely transported to the phrenic nuclei and to the intercostal motor nuclei. Subsequently WGA-Alexa 488 was transsynaptically transported from the phrenic motoneurons to the pre-motor neurons in the rVRG that provide the descending drive to the phrenic neurons during inspiration. In addition WGA-Alexa 488 was identified in select cells of the NA confirmed by a dual label of both WGA-Alexa 488 and True blue. WGA-Alexa 488 demonstrates retrograde transsynaptic labeling following intrapleural injection whereas the previous method of injecting CTB-Alexa 488 only demonstrates retrograde labeling. Intrapleural injection of WGA-Alexa fluor conjugates is an effective method to transsynaptically label the phrenic motor system providing an alternative for the invasive laparotomy required for intradiaphragmatic injections. Furthermore, the study provides the first anatomical evidence of a direct synaptic relationship between rVRG and select NA cells. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Mid-Face Volumization With Hyaluronic Acid: Injection Technique and Safety Aspects from a Controlled, Randomized, Double-Blind Clinical Study.

    Science.gov (United States)

    Prager, Welf; Agsten, Karla; Kravtsov, Maria; Kerscher, Prof Martina

    2017-04-01

    BACKGROUND: Injection of hyaluronic acid (HA) volumizing fillers in the malar area is intended for rejuvenation of the mid-face. The choice of products, depth, and technique of injection depends on the desired level of volume enhancement and practitioners' preferences. OBJECTIVE: To describe a volumizing injection technique in the scope of a controlled, randomized, double-blind, single-center, split-face clinical study. A total of 45 subjects with bilateral symmetrical moderate to severe volume loss in the malar area received a single 2 mL injection of CPM®-26 (Cohesive Polydensified Matrix®) on one side and VYC®-20 (VYCROSS®) on the contralateral side of the face. The same injection technique was applied for both sides of the face. Use of anesthetics, overcorrection, and touch-ups were not permitted. The investigator completed a product satisfaction questionnaire. Adverse events (AE) and injection-site reactions (ISRs) were reported during the study. RESULTS: The products were placed at the epiperiosteal depth in 88.9% (n=40), at the subdermal depth in 8.9% (n=4) and at both levels in 2.2% (n=1) of subjects. Fanning technique using cannulae was applied in most cases (97.8%, n=44). Results of the investigator satisfaction questionnaire allowed to characterize CPM-26 in comparison to other volumizing gels. Both study products were generally well tolerated. Local reactions were transient and of mild to moderate intensity, with the most frequent ones being redness, pain, and swelling. CONCLUSION: Adequate injection technique in volumizing treatments is essential to create a natural aesthetic rejuvenation while respecting the safety aspect of the procedures. A 22G blunt cannula used with CPM-26 was preferred due to an easier and a more homogeneous distribution of the product. The investigator also appreciated CPM-26 for its ease of injection, positioning, lifting, and volumizing capacity. J Drugs Dermatol. 2017;16(4):351-357..

  7. End-to-side neurorrhaphy with and without perineurium

    Directory of Open Access Journals (Sweden)

    Fausto Viterbo

    Full Text Available OBJECTIVE: We compared end-to-side neurorraphy with and without the perineural sheath. METHOD: Twenty rats were used. The peroneal nerve was sectioned and the distal end was sutured to the lateral face of the tibial nerve. We removed the perineural sheath only on the right side, but not on the left side. The proximal end of the peroneal nerve was curved back approximately at a 100° angle and implanted into the adductor muscle. Six months later, the 14 surviving animals were submitted to electrophysiological tests, sacrificed, and the nerves and muscles were taken for histological exams. RESULTS: On the right side, the muscles that had positive response needed an average of 258.89 mV (±92.31 of electric stimulus and on the left side 298.34 mV (±139.32. The average weight of the tibial cranial muscles of the right side was 0.47 g (0.18 and for the left side 0.45 g (0.15. The distal end of the peroneal nerve showed averages of 310.29 (±191.34 nerve fibers on the right side and 287.71 (±183.60 on the left side. The tibial nerve above the neurorraphy showed averages of 939.46 (±223.51 nerve fibers on the right side and 959.46 (±327.48 on the left side. The tibial nerve below the neurorraphy showed averages of 935.17 (±298.65 nerve fibers on the right side and 755.31 (±323.26 on the left side. The average areas of the right tibial cranial muscles were 0.0162 m2 (±0.008, after 230 magnification, and 0.0152 m2 (0.0064 for the left tibial cranial muscles. The histological features of the tibial cranial muscles, taking normal as 100%, were 78.21 (±20.75 on the right side and 82.14 (±15.89 on the left side. The statistical analysis (Student's t test did not reveal any difference (p>0.05 among right and left sides for all variables. CONCLUSION: The authors concluded that the two neurorraphies (with and without perineurium did not show any difference regarding morphological and electrophysiological features studied.

  8. Effect of warming anaesthetic solutions on pain during dental injection. A randomized clinical trial.

    Directory of Open Access Journals (Sweden)

    Pedro Christian Aravena

    2015-10-01

    Full Text Available Objective: To determine the effectiveness of warming anesthetic solutions on pain produced during the administration of anesthesia in maxillary dental infiltration technique. Material and Methods: A double-blind cross-over clinical study was designed. Fifty-six volunteer students (mean age 23.1±2.71 years of the Dental School at Universidad Austral de Chile (Valdivia, Chile participated in the study. Subjects were given 0.9ml of 2% lidocaine with 1:100.000 epinephrine (Alphacaine®; Nova DFL - Brazil by two punctions at buccal vestibule of lateral incisor. Warm anesthesia at 42°C (107.6°F was administered in a hemi-arch; and after one week anesthesia at room temperature (21°C; 69.8°F and at a standardized speed was administered at the contralateral side. The intensity of pain felt during injection was registered and compared using visual analog scale (VAS of 100mm (Wilcoxon test p<0.05. Results: The use of anesthesia at room temperature caused a VAS-pain intensity of 34.2±16.6mm, and anesthesia at 42°C a VAS-pain intensity of 15.7±17.4mm (p<0.0001. Conclusion: The use of anesthesia at 42°C resulted in a significantly lower pain intensity perception during injection compared with the use of anesthesia at room temperature during maxillary infiltration technique.

  9. [Basic Studies on Locoregional Injection of a Newly Designed Chitin Sol].

    Science.gov (United States)

    Chiba, Takehiro; Sugitachi, Akio; Kume, Kouhei; Segawa, Takenori; Nishinari, Yutaka; Ishida, Kaoru; Noda, Hironobu; Nishizuka, Satoshi; Kimura, Yusuke; Koeda, Keisuke; Sasaki, Akira

    2015-11-01

    Systemic chemotherapy in advanced cancer cases often provokes serious adverse events. We aimed to examine the fundamental properties and efficacy of a novel chitin sol, an anti-cancer agent with minor side effects designed to avoid the adverse effects of chemotherapy and enhance the QOL and ADL of patients. DAC-70 was used to create the novel agent termed DAC-70 sol. The anti-proliferative activity was assayed by the WST method using different types of cell lines. The anti-cancer efficacy of the novel agent was examined using cancer-bearing mice. DAC-70 sol was easily injectable through a 21-G needle. The sol suppressed proliferation of the cells in vitro. Intra-tumor injection of DAC-70 sol inhibited the rapid growth of solid tumors in the mice. CDDP-loaded DAC-70 sol, CDDP/DAC-70 sol, successfully controlled malignant ascites in the mice (psol and CDDP/DAC-70 sol is clinically useful as novel cancer chemotherapy for advanced cases. This warrants further clinical studies in cancer chemotherapy.

  10. Should continuous rather than single-injection interscalene block be routinely offered for major shoulder surgery? A meta-analysis of the analgesic and side-effects profiles.

    Science.gov (United States)

    Vorobeichik, L; Brull, R; Bowry, R; Laffey, J G; Abdallah, F W

    2018-04-01

    Major shoulder surgery is associated with moderate-to-severe pain, but consensus on the optimal analgesic approach is lacking. Continuous catheter-based interscalene block (CISB) prolongs the analgesic benefits of its single-injection counterpart (SISB), but concerns over CISB complications and difficulties in interpreting comparative evidence examining major and minor shoulder procedures simultaneously, despite their differences in postoperative pain, have limited CISB popularity. This meta-analysis evaluates the CISB analgesic role and complications compared with SISB for major shoulder surgery. We retrieved randomised controlled trials (RCTs) comparing the effects of CISB to SISB on analgesic outcomes and side-effects after major shoulder surgery. Postoperative opioid consumption at 24 h was designated as the primary outcome. Secondary outcomes included 24-48 h opioid consumption, postoperative rest and dynamic pain scores up to 72 h, time-to-first analgesic, recovery room and hospital stay durations, patient satisfaction, postoperative nausea and vomiting, respiratory function, and block-related complications. Data from 15 RCTs were pooled using random-effects modelling. Compared with SISB, CISB reduced 24- and 48-h oral morphine consumption by a weighted mean difference [95% confidence interval] of 50.9 mg [-81.6, -20.2], (P=0.001) and 44.7 mg [-80.9, -8.7], (Pshoulder surgery, without increasing side-effects, compared with SISB. The importance of CISB-related changes in respiratory indices is questionable. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  11. Transverse field-induced nucleation pad switching modes during domain wall injection

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, M. T.; Fry, P. W.; Schrefl, T.; Gibbs, M. R. J.; Allwood, D. A.; Im, M.-Y.; Fischer, P.

    2010-03-12

    We have used magnetic transmission X-ray microscopy (M-TXM) to image in-field magnetization configurations of patterned Ni{sub 80}Fe{sub 20} domain wall 'injection pads' and attached planar nanowires. Comparison with micromagnetic simulations suggests that the evolution of magnetic domains in rectangular injection pads depends on the relative orientation of closure domains in the remanent state. The magnetization reversal pathway is also altered by the inclusion of transverse magnetic fields. These different modes explain previous results of domain wall injection into nanowires. Even more striking was the observation of domain walls injecting halfway across the width of wider (>400 nm wide) wires but over wire lengths of several micrometers. These extended Neel walls can interact with adjacent nanowires and cause a switching in the side of the wire undergoing reversal as the domain wall continues to expand.

  12. Injectable barriers for waste isolation

    International Nuclear Information System (INIS)

    Persoff, P.; Finsterle, S.; Moridis, G.J.; Apps, J.; Pruess, K.; Muller, S.J.

    1995-03-01

    In this paper the authors report laboratory work and numerical simulation done in support of development and demonstration of injectable barriers formed from either of two fluids: colloidal silica or polysiloxane. Two principal problems addressed here are control of gel time and control of plume emplacement in the vadose zone. Gel time must be controlled so that the viscosity of the barrier fluid remains low long enough to inject the barrier, but increases soon enough to gel the barrier in place. During injection, the viscosity must be low enough to avoid high injection pressures which could uplift or fracture the formation. To test the grout gel time in the soil, the injection pressure was monitored as grouts were injected into sandpacks. When grout is injected into the vadose zone, it slumps under the influence of gravity, and redistributes due to capillary forces as it gels. The authors have developed a new module for the reservoir simulator TOUGH2 to model grout injection into the vadose zone, taking into account the increase of liquid viscosity as a function of gel concentration and time. They have also developed a model to calculate soil properties after complete solidification of the grout. The numerical model has been used to design and analyze laboratory experiments and field pilot tests. The authors present the results of computer simulations of grout injection, redistribution, and solidification

  13. Application of Local Injection of Botulinum Toxin A in Cosmetic Patients with Congenital Drooping Mouth Corner.

    Science.gov (United States)

    Qian, Wei; Zhang, Yan-Kun; Lv, Wei; Hou, Ying; Cao, Qian; Fan, Ju-Feng

    2016-12-01

    This study aimed to investigate the clinical application and efficacy of local injection of botulinum toxin A (BTX-A) at the depressor anguli oris in patients with congenital drooping mouth corner. From September 2013 to March 2015, 36 cosmetic patients received local injections of botulinum toxin A at the depressor anguli oris, with 1-3 injection sites in the moving region of the depressor anguli oris on each side. At each injection site, 2-4 U of BTX-A was injected, and the total dose for any unilateral treatment did not exceed 8 U. The change in the degree of drooping of the mouth corner before and after the injection was analyzed using statistical methods. The clinical efficacy, preservation time, and adverse reactions were observed. The degree of drooping of the mouth corners of the cosmetic patients before the treatment was compared with that at 1 month after using a paired t test, and the difference was statistically significant, with P injection. The local injection of BTX-A at the depressor anguli oris can effectively lift a drooping mouth corner, thereby improving the depressed, stern, and aged appearance of the face. The performance of this treatment is simple, safe, and easy to perform in clinical applications. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  14. Electron injection in microtron

    International Nuclear Information System (INIS)

    Axinescu, S.

    1977-01-01

    A review of the methods of injecting electrons in the microtron is presented. A special attention is paid to efficient injection systems developed by Wernholm and Kapitza. A comparison of advantages and disadvantages of both systems is made in relation to the purpose of the microtron. (author)

  15. Preferred chewing side-dependent two-point discrimination and cortical activation pattern of tactile tongue sensation.

    Science.gov (United States)

    Minato, Akiko; Ono, Takashi; Miyamoto, Jun J; Honda, Ei-ichi; Kurabayashi, Tohru; Moriyama, Keiji

    2009-10-12

    Although tactile feedback from the tongue should contribute to habitual chewing, it is unclear how the sensation of the tongue and its projection to the central nervous system differ with regard to the preferred chewing side (PCS). The purpose of this study was to investigate (1) whether the sensory threshold of the tongue differed according to the side and (2) whether the pattern of hemispheric cortical activation by tactile tongue stimulation differed, with special attention to the PCS. Twelve healthy adults participated in the study. The PCS was determined with a mandibular kinesiograph. In the behavioral study, the mean thresholds for two-point discrimination (TPD) in the anterior, canine and posterior regions on both sides of the tongue, and those between PCS and non-PCS in each region were statistically compared. In the functional magnetic resonance imaging study, tactile stimulation was delivered to either side of the tongue with acrylic balls via a mandibular splint. The runs were measured with a T2*-weighted gradient echo-type echo planar imaging sequence in a 1.5T scanner. Activated voxel numbers in the bilateral primary somatosensory cortex (S1) were statistically compared. The threshold of TPD increased in the order of the anterior, canine and posterior regions. Moreover, this threshold was significantly smaller on the PCS than on the non-PCS in both the canine and posterior regions. Moreover, the number of activated voxels in S1 contralateral to the PCS was significantly greater than that in S1 contralateral to the non-PCS. The present study shows that the PCS is associated with asymmetric tactile sensation and cortical activation of the tongue. The sensory acuity of the tongue on the PCS may play an important role in functional coupling between the jaw and tongue to maximize the efficiency of chewing.

  16. Injection laryngoplasty using BIOPEX calcium phosphate cement. The Sanokousei General Hospital experience

    International Nuclear Information System (INIS)

    Okubo, Keisuke; Shinnabe, Akihiro; Saito, Koichiro; Shiotani, Akihiro

    2008-01-01

    The calcium phosphate bone paste BIOPEX is an injectable material developed as a bone replacement that hardens into a hydroxylapatite block after injection. BIOPEX offers many advantages as a material for injection laryngoplasty: it induces little foreign-material reaction, is minimally absorbed, and is easy to prepare in the OR. Between 2004 and 2007, 14 patients, including 13 with vocal fold paralysis and 1 with severe atrophy of the vocal folds, were treated with BIOPEX-injection laryngoplasty at Sanokousei General Hospital. The injection of BIOPEX is usually performed through a direct laryngoscopy under general anesthesia, and no adverse effects were observed in any of the cases. A postoperative three-dimensional CT revealed successful injection of the BIOPEX into the paraglottic space in all cases. BIOPEX is minimally absorbed over long time periods, and this procedure results in a dramatic improvement of glottic function immediately after surgery. We consider this operative technique, which aims at medialization of the vocal fold by injection of a sclerotic agent into the lateral side of the vocal fold, as 'type I thyroplasty from inside the laryngeal framework.' (author)

  17. Prevalence of injections and knowledge of safe injections among rural residents in Central China.

    Science.gov (United States)

    Yan, Y W; Yan, J; Zhang, G P; Gao, Z L; Jian, H X

    2007-08-01

    Abuse of the injection services, namely unnecessary injections and unsafe injections, exists extensively in developing countries. Unsafe injection practices contribute to the transmission of blood-borne pathogens. The aims of this study were to survey the prevalence of injections and knowledge of injection safety among the rural residents in Jingzhou district, Hubei, China and to provide scientific data for developing a health educational programme. A retrospective cross-sectional study was conducted in 12 villages, which were selected from the Jingzhou district by the random sampling method. 50 rural residents were interviewed per village using a questionnaire. Among the 595 residents studied, 192 had received at least one injection in the past three months, with an injection prevalence of 32.3 percent and an average of 0.93 injections. 90.3 percent of the rural residents knew that unsafe injections could transmit the following blood-borne pathogens: human immunodeficiency virus (74.4 percent), hepatitis B virus (55.8 percent) and hepatitis C virus (22.9 percent). Logistic regression analysis showed that the residents' age, educational level and residential area were important factors in influencing their knowledge about injection safety. The results indicated that the injection prevalence was high among rural residents in the study area, and their knowledge regarding injection safety should be further improved.

  18. Controversy over nuclear power. Behavior of two sides and media from the point of communication

    International Nuclear Information System (INIS)

    Sata, Tsutomu

    2006-01-01

    The interaction process among the four groups such as the affirmative side, the reverse side, mass media and the people for nuclear power is analyzed from the point of communication. A definition of four groups, safety of the sites and economic induction, the affirmative side aims at persuasion, the reverse side appeals to feelings, mass media takes up news to amusement, articles dramatized on the basis of the fact, persuasion with threatening has the opposite effect, personal attitude is affected by the group criterion, media brings people's interaction into focus, people have a hatred for a one-sided information, and information with sincerity touches the heart are reported. (S.Y.)

  19. Improved side information generation for distributed video coding

    DEFF Research Database (Denmark)

    Huang, Xin; Forchhammer, Søren

    2008-01-01

    As a new coding paradigm, distributed video coding (DVC) deals with lossy source coding using side information to exploit the statistics at the decoder to reduce computational demands at the encoder. The performance of DVC highly depends on the quality of side information. With a better side...... information generation method, fewer bits will be requested from the encoder and more reliable decoded frames will be obtained. In this paper, a side information generation method is introduced to further improve the rate-distortion (RD) performance of transform domain distributed video coding. This algorithm...

  20. Enhanced oil recovery using improved aqueous fluid-injection methods: an annotated bibliography. [328 citations

    Energy Technology Data Exchange (ETDEWEB)

    Meister, M.J.; Kettenbrink, G.K.; Collins, A.G.

    1976-10-01

    This annotated bibliography contains abstracts, prepared by the authors, of articles published between 1968 and early 1976 on tests of improved aqueous fluid injection methods (i.e., polymer and surfactant floods). The abstracts have been written and organized to facilitate studies of the oil recovery potential of polymer and surfactant floods under known reservoir conditions. 328 citations.