WorldWideScience

Sample records for two-part camming device

  1. DYNAMIC ANALYSIS OF A CRIMPING DEVICE WITH MULTIPLE CAMS USING MSC ADAMS II

    Directory of Open Access Journals (Sweden)

    Gheorghe Popescu

    2012-05-01

    Full Text Available Through the present paper, the author presents the results of the dynamic analysis with MSC ADAMS of the mechanism with a crimping device with 12 tightening cams, designed and used in the technological process of assembly of the indigenous electrical detonators. In this sense, the mechanism with multiple cams is considered a mechanical system and is treated as an assembly of rigid bodies connected by mechanical connections and elastic elements. For shaping and simulation of the mechanism with multiple cams using ADAMS program, the author got through the following stages: construction of the pattern, its testing and simulation, validation, finishing, parametrization, optimization of the pattern.

  2. Motorized CPM/CAM physiotherapy device with sliding-mode Fuzzy Neural Network control loop.

    Science.gov (United States)

    Ho, Hung-Jung; Chen, Tien-Chi

    2009-11-01

    Continuous passive motion (CPM) and controllable active motion (CAM) physiotherapy devices promote rehabilitation of damaged joints. This paper presents a computerized CPM/CAM system that obviates the need for mechanical resistance devices such as springs. The system is controlled by a computer which performs sliding-mode Fuzzy Neural Network (FNN) calculations online. CAM-type resistance force is generated by the active performance of an electric motor which is controlled so as to oppose the motion of the patient's leg. A force sensor under the patient's foot on the device pedal provides data for feedback in a sliding-mode FNN control loop built around the motor. Via an active impedance control feedback system, the controller drives the motor to behave similarly to a damped spring by generating and controlling the amplitude and direction of the pedal force in relation to the patient's leg. Experiments demonstrate the high sensitivity and speed of the device. The PC-based feedback nature of the control loop means that sophisticated auto-adaptable CPM/CAM custom-designed physiotherapy becomes possible. The computer base also allows extensive data recording, data analysis and network-connected remote patient monitoring.

  3. Novel CAD/CAM rapid prototyping of next-generation biomedical devices

    Science.gov (United States)

    Doraiswamy, Anand

    An aging population with growing healthcare needs demands multifaceted tools for diagnosis and treatment of health conditions. In the near-future, drug-administration devices, implantable devices/sensors, enhanced prosthesis, artificial and unique functional tissue constructs will become increasingly significant. Conventional technologies for mass-produced implants do not adequately take individual patient anatomy into consideration. Development of novel CAD/CAM rapid prototyping techniques may significantly accelerate progress of these devices for next-generation patient-care. In this dissertation, several novel rapid prototyping techniques have been introduced for next-generation biomedical applications. Two-photon polymerization was developed to microfabricate scaffolds for tissue engineering, microneedles for drug-delivery and ossicular replacement prostheses. Various photoplymers were evaluated for feasibility, mechanical properties, cytotoxicity, and surface properties. Laser direct write using MDW was utilized for developing microstructures of bioceramics such as hydroxyapatite, and viable mammalian osteosarcoma cells. CAD/CAM laser micromachining (CLM) was developed to engineer biointerfaces as surface recognition regions for differential adherence of cells and growth into tissue-like networks. CLM was also developed for engineering multi-cellular vascular networks. Cytotoxic evaluations and growth studies demonstrated VEGF-induced proliferation of HAAE-1 human aortic endothelial cells with inhibition of HA-VSMC human aortic smooth muscle cells. Finally, piiezoelectric inkjet printing was developed for controlled administration of natural and synthetic adhesives to overcome several problems associated with conventional tissue bonding materials, and greatly improve wound-repair in next generation eye repair, fracture fixation, organ fixation, wound closure, tissue engineering, and drug delivery devices.

  4. Smartphone-based fundus camera device (MII Ret Cam) and technique with ability to image peripheral retina.

    Science.gov (United States)

    Sharma, Ashish; Subramaniam, Saranya Devi; Ramachandran, K I; Lakshmikanthan, Chinnasamy; Krishna, Soujanya; Sundaramoorthy, Selva K

    2016-01-01

    To demonstrate an inexpensive smartphone-based fundus camera device (MII Ret Cam) and technique with ability to capture peripheral retinal pictures. A fundus camera was designed in the form of a device that has slots to fit a smartphone (built-in camera and flash) and 20-D lens. With the help of the device and an innovative imaging technique, high-quality fundus videos were taken with easy extraction of images. The MII Ret Cam and innovative imaging technique was able to capture high-quality images of peripheral retina such as ora serrata and pars plana apart from central fundus pictures. Our smartphone-based fundus camera can help clinicians to monitor diseases affecting both central and peripheral retina. It can help patients understand their disease and clinicians convincing their patients regarding need of treatment especially in cases of peripheral lesions. Imaging peripheral retina has not been demonstrated in existing smartphone-based fundus imaging techniques. The device can also be an inexpensive tool for mass screening.

  5. A numerical method to enhance the performance of a cam-type electric motor-driven left ventricular assist device.

    Science.gov (United States)

    Huang, Huan; Yang, Ming; Lu, Cunyue; Xu, Liang; Zhuang, Xiaoqi; Meng, Fan

    2013-10-01

    Pulsatile left ventricular assist devices (LVADs) driven by electric motors have been widely accepted as a treatment of heart failure. Performance enhancement with computer assistance for this kind of LVAD has seldom been reported. In this article, a numerical method is proposed to assist the design of a cam-type pump. The method requires an integrated model of an LVAD system, consisting of a motor, a transmission mechanism, and a cardiovascular circulation. Performance indices, that is, outlet pressure, outlet flow, and pump efficiency, were used to select the best cam profile from six candidates. A prototype pump connected to a mock circulatory loop (MCL) was used to calibrate the friction coefficient of the cam groove and preliminarily evaluate modeling accuracy. In vitro experiments show that the mean outlet pressure and flow can be predicted with high accuracy by the model, and gross geometries of the measurements can also be reproduced. Simulation results demonstrate that as the total peripheral resistance (TPR) is fixed at 1.1 mm Hg.s/mL, the two-cycle 2/3-rise profile is the best. Compared with other profiles, the maximum increases of pressure and flow indices are 75 and 76%, respectively, and the maximum efficiency increase is over 51%. For different TPRs (0.5∼1.5 mm Hg.s/mL) and operation intervals (0.1∼0.4 s) in counterpulsation, the conclusion is also acceptable.

  6. Two-part set systems

    CERN Document Server

    Gerbner, Dániel; Lemons, Nathan; Mubayi, Dhruv; Palmer, Cory; Patkós, Balázs

    2011-01-01

    The two part Sperner theorem of Katona and Kleitman states that if $X$ is an $n$-element set with partition $X_1 \\cup X_2$, and $\\cF$ is a family of subsets of $X$ such that no two sets $A, B \\in \\cF$ satisfy $A \\subset B$ (or $B \\subset A$) and $A \\cap X_i=B \\cap X_i$ for some $i$, then $|\\cF| \\le {n \\choose \\lfloor n/2 \\rfloor}$. We consider variations of this problem by replacing the Sperner property with the intersection property and considering families that satisfiy various combinations of these properties on one or both parts $X_1$, $X_2$. Along the way, we prove the following new result which may be of independent interest: let $\\cF, \\cG$ be families of subsets of an $n$-element set such that $\\cF$ and $\\cG$ are both intersecting and cross-Sperner, meaning that if $A \\in \\cF$ and $B \\in \\cG$, then $A \

  7. Haptic devices and objects, robots and mannequin simulation in a CAD-CAM software: eM-Virtual Desktop

    CERN Document Server

    Chablat, Damien; Hoessler, Bernard; Guibert, Matthieu

    2011-01-01

    This paper presents the development of a new software in order to manage objects, robots and mannequins in using the possibilities given by the haptic feedback of the Phantom desktop devices. The haptic device provides 6 positional degrees of freedom sensing but three degrees force feedback. This software called eM-Virtual Desktop is integrated in the Tecnomatix's solution called eM-Workplace. The eM-Workplace provides powerful solutions for planning and designing of complex assembly facilities, lines and workplaces. In the digital mockup context, the haptic interfaces can be used to reduce the development cycle of products. Three different loops are used to manage the graphic, the collision detection and the haptic feedback according to theirs own frequencies. The developed software is currently tested in industrial context by a European automotive constructor.

  8. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  9. Is prayer CAM?

    Science.gov (United States)

    Tippens, Kim; Marsman, Kevin; Zwickey, Heather

    2009-04-01

    Alternative medicine researchers and policy makers have classified prayer as a mind-body intervention, and thus, a modality of complementary and alternative medicine (CAM). As such, numerous epidemiological surveys of CAM utilization-which have included prayer-depict increasing CAM use, particularly in specific racial and ethnic groups. This paper discusses the implications of conflating prayer and CAM, especially regarding the definitions of both concepts and the resulting statistics of CAM utilization.

  10. Consumer Health: CAM Claims

    Science.gov (United States)

    Healthy Lifestyle Consumer health Don't take all CAM claims at face value. Do your homework when considering CAM therapies. By ... dose of skepticism. Federal Trade Commission. http://www.consumer.ftc.gov/articles/0167-miracle-health-claims. Accessed ...

  11. Research in non-equalization machining method for spatial cam

    Institute of Scientific and Technical Information of China (English)

    Jun-hua CHEN; Yi-jie WU

    2008-01-01

    Many kinds of devices with cam have been widely used in various mechanical equipments.However,non-equalization machining for spatial cam trough remains to be a difficult problem.This paper focuses on the analysis of ruaning conditions and machining processes of spatial cam with oscillating follower.We point out the common errors in the biased distance cutting.By analyzing the motion of oscillating follower of spatial cam,we present a new 3D curve expansion model of spatial cam trough-outline.Based on this model.we have proposed a machining method for trochoidal milling with non-equalization diameter cutter.This new method has led to a creative and effective Way for non.equalization diameter machining for spatial cam with oscillating follower.

  12. 21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Optical Impression Systems for CAD/CAM. 872.3661... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or... Design and Manufacturing (CAD/CAM) of Dental Restorations; Guidance for Industry and FDA.” For...

  13. Composite cam carrier

    Energy Technology Data Exchange (ETDEWEB)

    Wicks, Christopher Donald; Madin, Mark Michael

    2017-03-14

    A cam carrier assembly includes a cylinder head having valves and a camshaft having lobes. A cam carrier has a first side coupled with the cylinder head engaging around the valves and a second side with bearing surfaces supporting the camshaft. A series of apertures extend between the first and second sides for the lobes to interface with the valves. The cam carrier is made of carbon fiber composite insulating the camshaft from the cylinder head and providing substantial weight reduction to an upper section of an associated engine.

  14. CAM and NK Cells

    Directory of Open Access Journals (Sweden)

    Kazuyoshi Takeda

    2004-01-01

    Full Text Available It is believed that tumor development, outgrowth and metastasis are under the surveillance of the immune system. Although both innate and acquired immune systems play roles, innate immunity is the spearhead against tumors. Recent studies have revealed the critical role of natural killer (NK cells in immune surveillance and that NK cell activity is considerably influenced by various agents, such as environmental factors, stress, foods and drugs. Some of these NK cell stimulants have been used in complementary and alternative medicine (CAM since ancient times. Therefore, the value of CAM should be re-evaluated from this point of view. In this review, we overview the intimate correlation between NK cell functions and CAM agents, and discuss possible underlying mechanisms mediating this. In particular, neuro-immune crosstalk and receptors for CAM agents are the most important and interesting candidates for such mechanisms.

  15. 凸轮式填料装置排料器的结构优化与运动仿真%Structure Optimization and Motion Simulation of Material Covering Device of Cam Tray Filler

    Institute of Scientific and Technical Information of China (English)

    姜迎春; 王君玲; 田佳玄; 张祖立

    2016-01-01

    Stress is affected by the thickness of sliding plate of material covering device of Cam tray filler .The minimum safety factor and allowable safety coefficient by comparing by static analysis of sliding plate , the thickness of sliding plate is optimized under the condition of meet the design requirements .so as to reduce weight and saving material of the mate-rial covering device .Motion simulation for centroid of roller of material covering device by the thickness of the sliding plate is optimized show that trajectory of roller centroid is corresponding by comparing cam contour line of theoretical de -sign;extending the length of sliding plate by displacement curve of roller is corresponding by comparing design ; radial velocity and acceleration curves of roller are accord with the design requirements .%在凸轮式填料装置的设计中,排料器滑板结构的厚度影响其应力。为此,对滑板结构进行了静力分析,并将最小安全系数与许用安全系数进行对比,在满足设计要求条件下对滑板结构的厚度进行优化,从而减轻排料器质量以节省材料。通过对滑板结构厚度优化后的排料器滚子质心的运动仿真可得到:滚子质心的运动轨迹与理论设计的凸轮轮廓线一致;滚子位移曲线所得到的滑板伸出滚筒长度的最大值与设计一致;滚子径向运动速度和加速度曲线规律符合设计要求。

  16. Approximation of the two-part MDL code

    NARCIS (Netherlands)

    Adriaans, P.; Vitányi, P.M.B.

    2009-01-01

    Approximation of the optimal two-part minimum description length (MDL) code for given data, through successive monotonically length-decreasing two-part MDL codes, has the following properties: (i) computation of each step may take arbitrarily long; (ii) we may not know when we reach the optimum, or

  17. Approximation of the two-part MDL code

    NARCIS (Netherlands)

    P. Adriaans; P.M.B. Vitányi (Paul)

    2009-01-01

    htmlabstractApproximation of the optimal two-part minimum description length (MDL) code for given data, through successive monotonically length-decreasing two-part MDL codes, has the following properties: (i) computation of each step may take arbitrarily long; (ii) we may not know when we reach the

  18. DATA TRANSLATION BETWEEN PADS AND CAM350

    Directory of Open Access Journals (Sweden)

    E. B. Romanova

    2015-07-01

    Full Text Available The subject matter of the paper is the process of data translation between computer-aided design system for electronic devices PADS VX and system for technological preparation of production of printed circuit boards CAM350 10. The object of this study is two-way translation of data in these systems. Experimental researches are applied as research methods based on repeated playback of forward and reverse data translation process between PADS and CAM350 systems. The aim is to examine the challenges of data exchange between systems and to find out the ways of their solution. The basis of the work is functionality analysis of PADS and CAM350 systems while data translation, which was carried out in the course of operating experience of these systems. The paper presents advantages and disadvantages of translation methods and their comparison. Errors arising in the process are analyzed. Possible reasons of errors origination are described. The main results are recommendations for data exchange between PADS and CAM350 systems. The proposed recommendations give the possibility to optimize the exchange of data between these systems. Practical significance of the work lies in the implementation of results at LLC «Abeo». Recommendations have been used in the development of dozens of different electronic devices. The use of these results made it possible to reduce the production run-up time, to increase data transmission correctness, thereby improving the quality of products and reduction of their cost.

  19. PreCam

    Energy Technology Data Exchange (ETDEWEB)

    Allam, Sahar S. [Fermilab; Tucker, Douglas L. [Fermilab

    2015-01-01

    The Dark Energy Survey (DES) will be taking the next step in probing the properties of Dark Energy and in understanding the physics of cosmic acceleration. A step towards the photometric calibration of DES is to have a quick, bright survey in the DES footprint (PreCam), using a pre-production set of the Dark Energy Camera (DECam) CCDs and a set of 100 mm×100 mm DES filters. The objective of the PreCam Survey is to create a network of calibrated DES grizY standard stars that will be used for DES nightly calibrations and to improve the DES global relative calibrations. Here, we describe the first year of PreCam observation, results, and photometric calibrations.

  20. Camønoen

    DEFF Research Database (Denmark)

    Gyimóthy, Szilvia; Widtfeld Meged, Jane

    2016-01-01

    Coastal communities in Denmark have experienced a steady socioeconomic decline, which has further been aggravated by a stagnating tourism and agricultural sector. Within this context, coastal regions are attempting to harness the potentials of the emerging collaborative economy and its...... and citizens alike? The recently opened pilgrim trail, Camønoen represents an adapted collaborative business model and as such an appropriate case to study new coastal value creation processes. Camønoen is a 175 km long newly designed walking trail across the islands of Møn, Nyord and Bogø. The trail...... to determine the social and economic potentials as well as pitfalls of auto-mediated collaborative business models in a coastal context....

  1. Roller Cam Positioners

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon B.

    2010-12-07

    Roller Cam Positioners could support the LCLS undulator sections allowing micron sized alignment adjustment of each undulator in 5 degrees of freedom. The supports are kinematic with the number of degrees of freedom matched to the number of constraints. Ton loads are supported on simple ball bearings. Motion is intrinsically bounded. Positioning mechanisms are based on pure rolling motion with sub-micron hysteresis and micron resolution. This note describes a general purpose positioning mechanism suitable for undulator support.

  2. Thyroid Disease and Complementary and Alternative Medicine (CAM)

    Science.gov (United States)

    ... Alternative Medicine (CAM) Thyroid Disease and Complementary and Alternative Medicine (CAM) WHAT IS COMPLEMENTARY AND ALTERNATIVE MEDICINE (CAM)? Complementary and Alternative Medicine (CAM) is defined ...

  3. Analysis of 3D curve expansion of conical cam with oscillating tapered roller follower

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    This paper focuses on the analysis of running conditions and machining processes of conical cam with oscillating follower. We point out the common errors existing in the design and machining of the widely used plane expansion method of conical cam trough-out line. We show that the motion can be divided into two parts, i.e. the oscillating motion of oscillating bar and the rotary motion of oscillating bar relative to the conical cam. By increasing the rotary motion of oscillating bar, the motion path of tapered roller on oscillating bar (i.e. contour surface of conical cam) can be expanded on the cylinder. Based on these analyses,we present a creative and effective designing and machining method for 3D curve expansion of conical cam with oscillating follower.

  4. Hydraulic involute cam actuator

    Science.gov (United States)

    Love, Lonnie J.; Lind, Randall F.

    2011-11-01

    Mechanical joints are provided in which the angle between a first coupled member and a second coupled member may be varied by mechanical actuators. In some embodiments the angle may be varied around a pivot axis in one plane and in some embodiments the angle may be varied around two pivot axes in two orthogonal planes. The joints typically utilize a cam assembly having two lobes with an involute surface. Actuators are configured to push against the lobes to vary the rotation angle between the first and second coupled member.

  5. A two-part model for censored medical cost data.

    Science.gov (United States)

    Tian, Lu; Huang, Jie

    2007-10-15

    The two-part model is often used to analyse medical cost data which contain a large proportion of zero cost and are highly skewed with some large costs. The total medical costs over a period of time are often censored due to incomplete follow-up, making the analysis difficult as the censoring can be informative. We propose to apply the inverse probability weighting method on a two-part model to analyse right-censored cumulative medical costs with informative censoring. We also introduce a set of simple functionals based on the intermediate cost history to be applied with the efficiency augmentation technique. In addition, we propose a practical model-checking technique based on the cumulative residuals. Simulation studies are conducted to evaluate the finite sample performance of the proposed method. We use a data set on the cardiovascular disease (CVD)-related Medicare costs to illustrate our proposed method.

  6. CAD/CAM data management

    Science.gov (United States)

    Bray, O. H.

    1984-01-01

    The role of data base management in CAD/CAM, particularly for geometric data is described. First, long term and short term objectives for CAD/CAM data management are identified. Second, the benefits of the data base management approach are explained. Third, some of the additional work needed in the data base area is discussed.

  7. CAD/CAM data management

    Science.gov (United States)

    Bray, O. H.

    1984-01-01

    The role of data base management in CAD/CAM, particularly for geometric data is described. First, long term and short term objectives for CAD/CAM data management are identified. Second, the benefits of the data base management approach are explained. Third, some of the additional work needed in the data base area is discussed.

  8. Optimisation Methods for Cam Mechanisms

    Directory of Open Access Journals (Sweden)

    Claudia–Mari Popa

    2010-01-01

    Full Text Available In this paper we present the criteria which represent the base of optimizing the cam mechanisms and also we perform the calculations for several types of mechanisms. We study the influence of the constructive parameters in case of the simple machines with rotation cam and follower (flat or curve of translation on the curvature radius and that of the transmission angle. As it follows, we present the optimization calculations of the cam and flat rotation follower mechanisms, as well as the calculations for optimizing the cam mechanisms by circular groove followers’ help. For an easier interpretation of the results, we have visualized the obtained cam in AutoCAD according to the script files generated by a calculation program.

  9. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  10. Rad Pole Cam Development

    Energy Technology Data Exchange (ETDEWEB)

    Heckendorn, F. M.; Odell, D. M. C; Harpring, L. J.; Peterson, K. D.

    2005-10-05

    The RadPoleCam was developed to provide Department Of Energy (DOE) first responders the capability to assess the radiological and visual condition of remote or inaccessible locations. Real time gamma isotopic identification is provided to the first responder in the form of audio feedback (i.e. spoken through head phones) from a gamma detector mounted on a collapsible pole that can extend from 1 to 9 meters (6 to 29 feet). Simultaneously, selectable direct and side looking visual images are provided from the 5cm (2in) diameter, waterproof probe tip. The lightweight, self contained, ruggedized, system will provide a rapidly deployable field system for visual and radiological search and assessment of confined spaces and extended reach locations.

  11. Cam-controlled boring bar

    Science.gov (United States)

    Glatthorn, Raymond H.

    1986-01-01

    A cam-controlled boring bar system (100) includes a first housing (152) which is rotatable about its longitudinal axis (154), and a second housing in the form of a cam-controlled slide (158) which is also rotatable about the axis (154) as well as being translatable therealong. A tool-holder (180) is mounted within the slide (158) for holding a single point cutting tool. Slide (158) has a rectangular configuration and is disposed within a rectangularly configured portion of the first housing (152). Arcuate cam slots (192) are defined within a side plate (172) of the housing (152), while cam followers (194) are mounted upon the cam slide (158) for cooperative engagement with the cam slots (192). In this manner, as the housing (152) and slide (158) rotate, and as the slide (158) also translates, a through-bore (14) having an hourglass configuration will be formed within a workpiece (16) which may be, for example, a nuclear reactor steam generator tube support plate.

  12. An open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and industrial CAM software.

    Science.gov (United States)

    Lu, Li; Liu, Shusheng; Shi, Shenggen; Yang, Jianzhong

    2011-10-01

    China-made 5-axis simultaneous contouring CNC machine tool and domestically developed industrial computer-aided manufacture (CAM) technology were used for full crown fabrication and measurement of crown accuracy, with an attempt to establish an open CAM system for dental processing and to promote the introduction of domestic dental computer-aided design (CAD)/CAM system. Commercially available scanning equipment was used to make a basic digital tooth model after preparation of crown, and CAD software that comes with the scanning device was employed to design the crown by using domestic industrial CAM software to process the crown data in order to generate a solid model for machining purpose, and then China-made 5-axis simultaneous contouring CNC machine tool was used to complete machining of the whole crown and the internal accuracy of the crown internal was measured by using 3D-MicroCT. The results showed that China-made 5-axis simultaneous contouring CNC machine tool in combination with domestic industrial CAM technology can be used for crown making and the crown was well positioned in die. The internal accuracy was successfully measured by using 3D-MicroCT. It is concluded that an open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and domestic industrial CAM software has been established, and development of the system will promote the introduction of domestically-produced dental CAD/CAM system.

  13. Development of CAD/CAM System for Cross Section’s Changing Hole Electrical Discharge Machining

    Science.gov (United States)

    Ishida, Tohru; Ishiguro, Eiki; Kita, Masahiko; Nakamoto, Keiichi; Takeuchi, Yoshimi

    This study deals with the development of a new CAD/CAM system for fabricating holes whose cross sections change variously. The cross sections of machined holes are generally constant. The limitations in the shapes of holes that can be machined make obstacles in the design stage of industrial products. A new device that utilizes electrical discharge machining has been developed that can create holes with various cross sections to solve this problem. However, it has been impossible to put the device into practical use since there has been no software that has enabled the designed shapes to be easily machined. Therefore, we aimed at developing a new CAD/CAM system for machining the beforehand designed holes with changing cross sections by using the device. As the first step in developing the CAD/CAM system, the post processor in the CAM system is formulated in this paper.

  14. CAD/CAM for optomechatronics

    Science.gov (United States)

    Zhou, Haiguang; Han, Min

    2003-10-01

    We focus at CAD/CAM for optomechatronics. We have developed a kind of CAD/CAM, which is not only for mechanics but also for optics and electronic. The software can be used for training and education. We introduce mechanical CAD, optical CAD and electrical CAD, we show how to draw a circuit diagram, mechanical diagram and luminous transmission diagram, from 2D drawing to 3D drawing. We introduce how to create 2D and 3D parts for optomechatronics, how to edit tool paths, how to select parameters for process, how to run the post processor, dynamic show the tool path and generate the CNC programming. We introduce the joint application of CAD&CAM. We aim at how to match the requirement of optical, mechanical and electronics.

  15. Scleroderma, Stress and CAM Utilization

    Directory of Open Access Journals (Sweden)

    Ka-Kit Hui

    2009-01-01

    Full Text Available Scleroderma is an autoimmune disease influenced by interplay among genetic and environmental factors, of which one is stress. Complementary and alternative medicine (CAM is frequently used to treat stress and those diseases in which stress has been implicated. Results are presented from a survey of patients with scleroderma. Respondents were a convenient sample of those attending a national conference in Las Vegas in 2002. Findings implicate stress in the onset, continuation and exacerbation of scleroderma. The implication is that CAM providers may be filling an important patient need in their provision of services that identify and treat stress and its related disorders.

  16. Depth Profiles Using ChemCam

    Science.gov (United States)

    Cousin, A.; Maurice, S.; Berger, G.; Forni, O.; Gasnault, O.; Wiens, R.

    2011-03-01

    ChemCam, which is in part of the MSL payload, uses the LIBS technique to investigate the martian surface. The capabilities of ChemCam for the depth profile have to be understood, as ChemCam will shoot several targets which can have alteration coating.

  17. The detection of EpCAM

    NARCIS (Netherlands)

    Wit, De Sanne; Dalum, Van Guus; Lenferink, Aufried T.M.; Tibbe, Arjan G.J.; Hiltermann, T.J.N.; Groen, Harry J.M.; Rijn, Van C.J.M.; Terstappen, Leon W.M.M.

    2015-01-01

    EpCAM expressing circulating tumor cells, detected by CellSearch, are predictive of short survival in several cancers and may serve as a liquid biopsy to guide therapy. Here we investigate the presence of EpCAM+ CTC detected by CellSearch and EpCAM- CTC discarded by CellSear

  18. Design of Cylindrical Cam with Oscillating Follower Based on 3D Expansion of Planar Profile Model

    Institute of Scientific and Technical Information of China (English)

    CHEN Junhua; LIN Zuan; WU Yijie

    2009-01-01

    Cylindrical cam with oscillating follower is widely applicable and used in many mechanical devices and machines. However, a common error exists in the methods of designing planar profile for oscillating follower cylinder cam. In this study, we propose a new hypothesis to solve this design problem with the inclusion of deviation angle. On the basis of this new concept, equations for planar profile expansion and methods of calculating pressure angle are deduced by applying 3D expansion formula of the follower's motion orbit. When the pressure angle is less than allowable value, the minimum base radius can be determined by using MATLAB software. Accordingly, the planar profile of oscillating follower cylinder cam is generated by CAD software. This new method is practical and can be easily adopted for the design of oscillating follower cylindrical cam with desirable accuracy. We applied the method in the design of cylindrical cam for paper feeding mechanism used in high-speed printers. We calculated the planar profile and used it to direct the NC machine for the manufacture of the groove of cylindrical cam. The improved cylindrical cam met all of the requirements of speed and accuracy demanded by high-speed printers. Therefore, our new method has been validated by practical application.

  19. CAMS 2009 PC Co-chairs' Message

    Science.gov (United States)

    Hinze, Annika; Buchanan, George

    In the four years since the first CAMS workshop, context awareness has become an increasingly commonplace tool for mobile developers. The limited screen displays of many mobile devices mean that content must be carefully selected to match the user's needs and expectations, and context provides one powerful means of performing such tailoring. Furthermore, increasing availability of additional hardware sensors has bolstered the use of context. GPS, Near-Field Communication, Bluetooth and WiFi have all been used to sense the general environment and to determine the devices' location. Light and tilt sensors have also been used to tune simple features such as the strength of the display lighting, through to complex uses in game control. Context-aware mobile systems are becoming ubiquitous. With this hardware comes the opportunity for "on-board" applications to use location data to provide new services - until recently such systems could only be created with complex and expensive components. Furthermore, the current "mode" of the phone (e.g., silent, meeting, outdoors), contents of the built-in calendar, etc., can all used to provide a rich context for the user's immediate environment.

  20. Hazmat Cam Wireless Video System

    Energy Technology Data Exchange (ETDEWEB)

    Kevin L. Young

    2006-02-01

    This paper describes the Hazmat Cam Wireless Video System and its application to emergency response involving chemical, biological or radiological contamination. The Idaho National Laboratory designed the Hazmat Cam Wireless Video System to assist the National Guard Weapons of Mass Destruction - Civil Support Teams during their mission of emergency response to incidents involving weapons of mass destruction. The lightweight, handheld camera transmits encrypted, real-time video from inside a contaminated area, or hot-zone, to a command post located a safe distance away. The system includes a small wireless video camera, a true-diversity receiver, viewing console, and an optional extension link that allows the command post to be placed up to five miles from danger. It can be fully deployed by one person in a standalone configuration in less than 10 minutes. The complete system is battery powered. Each rechargeable camera battery powers the camera for 3 hours with the receiver and video monitor battery lasting 22 hours on a single charge. The camera transmits encrypted, low frequency analog video signals to a true-diversity receiver with three antennas. This unique combination of encryption and transmission technologies delivers encrypted, interference-free images to the command post under conditions where other wireless systems fail. The lightweight camera is completely waterproof for quick and easy decontamination after use. The Hazmat Cam Wireless Video System is currently being used by several National Guard Teams, the US Army, and by fire fighters. The system has been proven to greatly enhance situational awareness during the crucial, initial phase of a hazardous response allowing commanders to make better, faster, safer decisions.

  1. Onzichtbare beugels dankzij CAD-CAM

    NARCIS (Netherlands)

    F.R. de Winter

    2011-01-01

    De introductie van de cad-cam-techniek in de tandheelkunde heeft in de orthodontie geleid tot het orthodontisch verplaatsen van gebitselementen met een serie opeenvolgende dieptrekplaten, ontworpen en gefabriceerd met behulp van cad-cam. Daarbij is iedere plaat een kleine stap in de richting van de

  2. Strategies for the Design of a Slide-o-Cam Transmission

    CERN Document Server

    Chablat, Damien

    2007-01-01

    The optimization of the pressure angle in a cam-follower transmission is reported in this paper. This transmission is based on Slide-o-Cam, a cam mechanism with multiple rollers mounted on a common translating follower. The design of Slide-o-Cam, a transmission intended to produce a sliding motion from a turning drive, or vice versa, was reported elsewhere. This transmission provides pure-rolling motion, thereby reducing the friction of rack-and-pinions and linear drives. The pressure angle is a suitable performance index for this transmission because it determines the amount of force transmitted to the load vs. that transmitted to the machine frame. Two alternative design strategies are studied, namely, (i) increase the number of lobes on each cam or (ii) increase the number of cams. This device is intended to replace the current ball-screws in Orthoglide, a three-DOF parallel robot for the production of translational motions, currently under development at Ecole Centrale de Nantes for machining applications...

  3. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  4. Materials for chairside CAD/CAM restorations.

    Science.gov (United States)

    Fasbinder, Dennis J

    2010-01-01

    Chairside computer-aided design/computer-aided manufacturing (CAD/CAM) systems have become considerably more accurate, efficient, and prevalent as the technology has evolved in the past 25 years. The initial restorative material option for chairside CAD/CAM restorations was limited to ceramic blocks. Restorative material options have multiplied and now include esthetic ceramics, high-strength ceramics, and composite materials for both definitive and temporary restoration applications. This article will review current materials available for chairside CAD/CAM restorations.

  5. CAM Stochastic Volatility Model for Option Pricing

    Directory of Open Access Journals (Sweden)

    Wanwan Huang

    2016-01-01

    Full Text Available The coupled additive and multiplicative (CAM noises model is a stochastic volatility model for derivative pricing. Unlike the other stochastic volatility models in the literature, the CAM model uses two Brownian motions, one multiplicative and one additive, to model the volatility process. We provide empirical evidence that suggests a nontrivial relationship between the kurtosis and skewness of asset prices and that the CAM model is able to capture this relationship, whereas the traditional stochastic volatility models cannot. We introduce a control variate method and Monte Carlo estimators for some of the sensitivities (Greeks of the model. We also derive an approximation for the characteristic function of the model.

  6. THE FOURIER SERIES USED IN ANALYSE OF THE CAM MECHANISMS FOR THE SHOEMAKING MACHINES (PART II

    Directory of Open Access Journals (Sweden)

    IOVAN-DRAGOMIR Alina

    2016-05-01

    Full Text Available A computer assisted procedure for the cinematic analysis of the mechanism of a cam is essential in making a certain type of research operations. They mainly refer to the optimization of operations running on specific machinery, or to the re-design of the mechanism, in order to make the mechanism digital. This analysis seems even more important, when we consider the fact that most of the machines used in shoe industry nowadays use a cam mechanism. The paper is devided in two parts. In first part, it is elaborated a method of finding of a function G(x, belonging to a Fourier series, which approximates the numerical values {xi, yi}, with the biggest accuracy. Finding the function that approximates the most accurately the data set, for the position parameters of the follower S(ω, ( will lead to a complete kinematic and dynamic analysis of the cam mechanism. These values repeat with T = 2π period. In second part, the method is tasted using MatCAD work sessions which allow a numerical and graphical analysis of the mathematical relations involved, in order to test the reability of the method. The set of experimental data are resulted after measuring a cam mechanism of a machine used in shoemaking.

  7. A Review of CAM for Procedural Pain in Infancy: Part II. Other Interventions

    Directory of Open Access Journals (Sweden)

    Jennie C. I. Tsao

    2008-01-01

    Full Text Available This article is the second in a two-part series reviewing the empirical evidence for complementary and alternative medicine (CAM approaches for the management of pain related to medical procedures in infants up to 6 weeks of age. Part I of this series investigated the effects of sucrose with or without non-nutritive sucking (NNS. The present article examines other CAM interventions for procedural pain including music-based interventions, olfactory stimulation, kangaroo care and swaddling. Computerized databases were searched for relevant studies including prior reviews and primary trials. Preliminary support was revealed for the analgesic effects of the CAM modalities reviewed. However, the overall quality of the evidence for these approaches remains relatively weak. Additional well-designed trials incorporating rigorous methodology are required. Such investigations will assist in the development of evidence-based guidelines on the use of CAM interventions either alone or in concert with conventional approaches to provide safe, reliable analgesia for infant procedural pain.

  8. THE FOURIER SERIES USED IN ANALYSE OF THE CAM MECHANISMS FOR THE SHOEMAKING MACHINES (PART I

    Directory of Open Access Journals (Sweden)

    IOVAN-DRAGOMIR Alina

    2016-05-01

    Full Text Available A computer assisted procedure for the cinematic analysis of the mechanism of a cam is essential in making a certain type of research operations. They mainly refer to the optimization of operations running on specific machinery, or to the re-design of the mechanism, in order to make the mechanism digital. This analysis seems even more important, when we consider the fact that most of the machines used in shoe industry nowadays use a cam mechanism. The paper is devided in two parts. In first part, it is elaborated a method of finding of a function G(x, belonging to a Fourier series, which approximates the numerical values {xi, yi}, with the biggest accuracy. Finding the function that approximates the most accurately the data set, for the position parameters of the follower S(ω, ( will lead to a complete kinematic and dynamic analysis of the cam mechanism. These values repeat with T = 2π period. In second part, the method is tasted using MatCAD work sessions which allow a numerical and graphical analysis of the mathematical relations involved, in order to test the reability of the method. The set of experimental data are resulted after measuring a cam mechanism of a machine used in shoemaking.

  9. An investigation of the standard of classification of retinal hemorrhage in full-term normal delivery newborns ;according to digital wide-angle retinal imaging device RetCam-3%Retcam-3检查足月新生儿视网膜出血分级的初步探讨

    Institute of Scientific and Technical Information of China (English)

    王雅丛; 耿韶辉; 李艳涛; 王玉芳; 张红; 张婷婷; 张佳佳; 张炜

    2015-01-01

    Objective To probe the classification of retinal hemorrhage(RH)in vaginal delivery term newborns accord-ing to digital wide-angle retinal imaging device(RetCam-3 ).Methods A total of 1 021 healthy full-term normal delivery newborns(2 042 eyes)were enrolled in this study.A digital wide-angle retinal imaging device(RetCam m)was used to examine the subjects at about 3 days after birth.Newborns with RH were reexamined after three,four and six weeks.RH was classified according to the location of RH and degree of hemorrhage in macular by RetCam-3.Results In 1 021 cases of newborns,retinal hemorrhages were found in 165 infants(17.14%).Within these 165 infants,155 infants(16.16%)wereⅠdegree retinal hemorrhage,9 infants(0.88%)were Ⅱdegree retinal hemorrhage and 1 infant (0.01%)was Ⅲ degree retinal hemorrhage.The average time of second stage of labor in newborns without RH was 49.81 ±5.3 minites.The average time of second stage of labor in newborns with RH was 51.13 ±6.12 minutes.New-borns with RH had longer second stage of labor than those without RH.The difference was statistically significant (t =2.839,P =0.005).Conclusion According to the result of RetCam-3 of 2 042 eyes,we classify RH in degreeⅠ,Ⅱand Ⅲ.RH of DegreeⅠis located in the superficial retina and resolves itself within three weeks after birth.RH of DegreeⅡ is located in the superficial retina including macular and resolves itself within six weeks after birth.RH of De-gree Ⅲ is located ahead of retina including macular and does not resolve itself within six weeks after birth.Prolonged second stage of labor may play roles of risk factor in retinal hemorrhage.%目的:采用广域数码视网膜成像系统(Retcam-3)探讨足月新生儿视网膜出血的分级方法。方法对1021例顺产足月新生儿(2042眼)出生3 d 内进行 Retcam-3眼底照相,初次检查发现视网膜出血者分别于3、4、6周后复查眼底。根据视网膜出血位置和黄斑出血程度对视

  10. Knowledge and training needs among Danish nurses about CAM

    DEFF Research Database (Denmark)

    Lunde, Anita

    2010-01-01

    to explore nurses’ knowledge about CAM and their needs for training. Methods: Similar to international investigations a Danish “CAM-knowledge” questionnaire was developed that included multiple choice, yes/no and 5 points scale answers. Validity was established through initial pilot testing. Contacts...... of CAM also tend to have a theoretical background of CAM. Around 75 % of the nurses agree or partly agree that it is important for nurses to receive education about CAM and that nurses have knowledge about CAM that enables them to advise patients. Training needs concerning CAM were indicated by 52....... Conclusion: Among Danish nurses CAM knowledge can be described as minor or average and a minority already has CAM education. Additional CAM training would be welcomed by more than half of the respondents in this survey....

  11. Patients’ views of CAM as spiritual practice

    DEFF Research Database (Denmark)

    Ulrich, Anita; Evron, Lotte; Ostenfeld-Rosenthal, Ann

    2011-01-01

    Objectives: This paper explores Danish cancer patients’ narratives on spiritual beliefs, practices and the relationship these practices may have to complementary and alternative medicine (CAM). Design: Narrative inquiry was used to understand how spiritual beliefs and practices might be related t....... For some individuals a belief in the ‘spiritual’ role of CAM per se may be analogous to religious belief.......Objectives: This paper explores Danish cancer patients’ narratives on spiritual beliefs, practices and the relationship these practices may have to complementary and alternative medicine (CAM). Design: Narrative inquiry was used to understand how spiritual beliefs and practices might be related...... to CAM. Thirty-two cancer patients, family, friends and alternative practitioners were followed up over a two year period by face to face interview, telephone and focus groups. Results: Although religious and spiritual issues were not manifestly expressed by many of the subjects, these issues were...

  12. AFSC/FMA/CAMS Data Objects

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The CAMS system consists of a set of tables and packages that provide authentication services to all other North Pacific Groundfish and Halibut Observing Program...

  13. CAM and stack air sampler design guide

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, T.D.

    1994-05-13

    About 128 air samplers and CAMs presently in service to detect and document potential radioactive release from `H` and `F` area tank farm ventilation stacks are scheduled for replacement and/or upgrade by Projects S-5764, S-2081, S-3603, and S-4516. The seven CAMs scheduled to be upgraded by Project S-4516 during 1995 are expected to provide valuable experience for the three remaining projects. The attached document provides design guidance for the standardized High Level Waste air sampling system.

  14. Model Documentation for the MiniCAM

    Energy Technology Data Exchange (ETDEWEB)

    Brenkert, Antoinette L.; Smith, Steven J.; Kim, Son H.; Pitcher, Hugh M.

    2003-07-17

    The MiniCAM, short for the Mini-Climate Assessment Model, is an integrated assessment model of moderate complexity focused on energy and agriculture sectors. The model produces emissions of greenhouse gases (carbon dioxide, methane and nitrous oxide) and other radiatively important substances such as sulfur dioxide. Through incorporation of the simple climate model MAGICC, the consequences of these emissions for climate change and sea-level rise can be examined. The MiniCAM is designed to be fast and flexible.

  15. Chiropractic and CAM Utilization: A Descriptive Review

    Directory of Open Access Journals (Sweden)

    Meeker William C

    2007-01-01

    Full Text Available Abstract Objective To conduct a descriptive review of the scientific literature examining use rates of modalities and procedures used by CAM clinicians to manage chronic LBP and other conditions Data Sources A literature of PubMed and MANTIS was performed using the key terms Chiropractic; Low Back Pain; Utilization Rate; Use Rate; Complementary and Alternative Medicine; and Health Services in various combinations. Data Selection A total of 137 papers were selected, based upon including information about chiropractic utilization, CAM utilization and low back pain and other conditions. Data Synthesis Information was extracted from each paper addressing use of chiropractic and CAM, and is summarized in tabular form. Results Thematic analysis of the paper topics indicated that there were 5 functional areas covered by the literature: back pain papers, general chiropractic papers, insurance-related papers, general CAM-related papers; and worker's compensation papers. Conclusion Studies looking at chiropractic utilization demonstrate that the rates vary, but generally fall into a range from around 6% to 12% of the population, most of whom seek chiropractic care for low back pain and not for organic disease or visceral dysfunction. CAM is itself used by people suffering from a variety of conditions, though it is often used not as a primary intervention, but rather as an additional form of care. CAM and chiropractic often offer lower costs for comparable results compared to conventional medicine.

  16. Genomic analyses of the CAM plant pineapple.

    Science.gov (United States)

    Zhang, Jisen; Liu, Juan; Ming, Ray

    2014-07-01

    The innovation of crassulacean acid metabolism (CAM) photosynthesis in arid and/or low CO2 conditions is a remarkable case of adaptation in flowering plants. As the most important crop that utilizes CAM photosynthesis, the genetic and genomic resources of pineapple have been developed over many years. Genetic diversity studies using various types of DNA markers led to the reclassification of the two genera Ananas and Pseudananas and nine species into one genus Ananas and two species, A. comosus and A. macrodontes with five botanical varieties in A. comosus. Five genetic maps have been constructed using F1 or F2 populations, and high-density genetic maps generated by genotype sequencing are essential resources for sequencing and assembling the pineapple genome and for marker-assisted selection. There are abundant expression sequence tag resources but limited genomic sequences in pineapple. Genes involved in the CAM pathway has been analysed in several CAM plants but only a few of them are from pineapple. A reference genome of pineapple is being generated and will accelerate genetic and genomic research in this major CAM crop. This reference genome of pineapple provides the foundation for studying the origin and regulatory mechanism of CAM photosynthesis, and the opportunity to evaluate the classification of Ananas species and botanical cultivars.

  17. Transparency in Dutch CAM practices: a comparison between CAM and GP physicians.

    NARCIS (Netherlands)

    Heiligers, P.; Dulmen, S. van

    2009-01-01

    Introduction: CAM (Complementary and Alternative Medicine) is increasing worldwide because the demand is growing. Transparency is needed to provide more objective information about CAM services, to date largely unknown by a majority of care users and mainstream care providers. Despite the fact that

  18. Sample selection versus two-part models revisited: the case of female smoking and drinking.

    Science.gov (United States)

    Madden, David

    2008-03-01

    There is a well-established debate between Heckman sample selection and two-part models in health econometrics, particularly when no obvious exclusion restrictions are available. Most of this debate has focussed on the application of these models to health care expenditure. This paper revisits the debate in the context of female smoking and drinking, and evaluates the two approaches on three grounds: theoretical, practical and statistical. The two-part model is generally favoured but it is stressed that this comparison should be carried out on a case-by-case basis.

  19. A Study on Digital Analysis of Bach’s “Two-Part Inventions”

    Directory of Open Access Journals (Sweden)

    Xiao-Yi Song

    2015-01-01

    Full Text Available In the field of music composition, creating polyphony is relatively one of the most difficult parts. Among them, the basis of multivoice polyphonic composition is two-part counterpoint. The main purpose of this paper is, through the computer technology, conducting a series of studies on “Two-Part Inventions” of Bach, a Baroque polyphony master. Based on digitalization, visualization and mathematical methods, data mining algorithm has been applied to identify bipartite characteristics and rules of counterpoint polyphony. We hope that the conclusions drawn from the article could be applied to the digital creation of polyphony.

  20. Next Generation CAD/CAM/CAE Systems

    Science.gov (United States)

    Noor, Ahmed K. (Compiler); Malone, John B. (Compiler)

    1997-01-01

    This document contains presentations from the joint UVA/NASA Workshop on Next Generation CAD/CAM/CAE Systems held at NASA Langley Research Center in Hampton, Virginia on March 18-19, 1997. The presentations focused on current capabilities and future directions of CAD/CAM/CAE systems, aerospace industry projects, and university activities related to simulation-based design. Workshop attendees represented NASA, commercial software developers, the aerospace industry, government labs, and academia. The workshop objectives were to assess the potential of emerging CAD/CAM/CAE technology for use in intelligent simulation-based design and to provide guidelines for focused future research leading to effective use of CAE systems for simulating the entire life cycle of aerospace systems.

  1. The chick embryo chorioallantoic membrane (CAM) assay.

    Science.gov (United States)

    Ribatti, Domenico

    2017-06-01

    During avian development the mesodermal layers of the allantois and chorion fuse to form the chorioallantoic membrane (CAM). This structure rapidly expands generating a rich vascular network that provides an interface for gas and waste exchange. The CAM allows to study tissue grafts, tumor growth and metastasis, drugs delivery and toxicologic analysis, and angiogenic and anti-angiogenic molecules. The CAM is relatively simple, quick, and low-cost model that allows screening of a large number of pharmacological samples in a short time; does not require administrative procedures for obtaining ethics committee approval for animal experimentation. Moreover, being naturally immunodeficient, the chick embryo may receive transplantations from different tissues and species, without immune responses. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. CAM practitioners in the Australian health workforce: an underutilized resource

    Directory of Open Access Journals (Sweden)

    Grace Sandra

    2012-11-01

    Full Text Available Abstract Background CAM practitioners are a valuable but underutilizes resource in Australian health care. Despite increasing public support for complementary and alternative medicine (CAM little is known about the CAM workforce. Apart from the registered professions of chiropractic, osteopathy and Chinese medicine, accurate information about the number of CAM practitioners in the workforce has been difficult to obtain. It appears that many non-registered CAM practitioners, although highly qualified, are not working to their full capacity. Discussion Increasing public endorsement of CAM stands in contrast to the negative attitude toward the CAM workforce by some members of the medical and other health professions and by government policy makers. The marginalisation of the CAM workforce is evident in prejudicial attitudes held by some members of the medical and other health professions and its exclusion from government policy making. Inconsistent educational standards has meant that non-registered CAM practitioners, including highly qualified and competent ones, are frequently overlooked. Legitimising their contribution to the health workforce could alleviate workforce shortages and provide opportunities for redesigned job roles and new multidisciplinary teams. Priorities for better utilisation of the CAM workforce include establishing a guaranteed minimum education standard for more CAM occupation groups through national registration, providing interprofessional education that includes CAM practitioners, developing courses to upgrade CAM practitioners' professional skills in areas of indentified need, and increasing support for CAM research. Summary Marginalisation of the CAM workforce has disadvantaged those qualified and competent CAM practitioners who practise evidence-informed medicine on the basis of many years of university training. Legitimising and expanding the important contribution of CAM practitioners could alleviate projected health

  3. A Cost-Effective Two-Part Experiment for Teaching Introductory Organic Chemistry Techniques

    Science.gov (United States)

    Sadek, Christopher M.; Brown, Brenna A.; Wan, Hayley

    2011-01-01

    This two-part laboratory experiment is designed to be a cost-effective method for teaching basic organic laboratory techniques (recrystallization, thin-layer chromatography, column chromatography, vacuum filtration, and melting point determination) to large classes of introductory organic chemistry students. Students are exposed to different…

  4. Web-based CAD and CAM for optomechatronics

    Science.gov (United States)

    Han, Min; Zhou, Hai-Guang

    2001-10-01

    CAD & CAM technologies are being used in design and manufacturing process, and are receiving increasing attention from industries and education. We have been researching to develop a new kind of software that is for web-course CAD & CAM. It can be used either in industries or in training, it is supported by IE. Firstly, we aim at CAD/CAM for optomechatronics. We have developed a kind of CAD/CAM, which is not only for mechanics but also for optics and electronic. That is a new kind of software in China. Secondly, we have developed a kind of software for web-course CAD & CAM, we introduce the basis of CAD, the commands of CAD, the programming, CAD/CAM for optomechatronics, the joint application of CAD & CAM. We introduce the functions of MasterCAM, show the whole processes of CAD/CAM/CNC by examples. Following the steps showed on the web, the trainer can not miss. CAD & CAM are widely used in many areas, development of web-course CAD & CAM is necessary for long- distance education and public education. In 1992, China raised: CAD technique, as an important part of electronic technology, is a new key technique to improve the national economic and the modernization of national defence. As so for, the education. Of CAD & CAM is mainly involved in manufacturing industry in China. But with the rapidly development of new technology, especially the development of optics and electronics, CAD & CAM will receive more attention from those areas.

  5. Georeferencing CAMS data: Polynomial rectification and beyond

    Science.gov (United States)

    Yang, Xinghe

    The Calibrated Airborne Multispectral Scanner (CAMS) is a sensor used in the commercial remote sensing program at NASA Stennis Space Center. In geographic applications of the CAMS data, accurate geometric rectification is essential for the analysis of the remotely sensed data and for the integration of the data into Geographic Information Systems (GIS). The commonly used rectification techniques such as the polynomial transformation and ortho rectification have been very successful in the field of remote sensing and GIS for most remote sensing data such as Landsat imagery, SPOT imagery and aerial photos. However, due to the geometric nature of the airborne line scanner which has high spatial frequency distortions, the polynomial model and the ortho rectification technique in current commercial software packages such as Erdas Imagine are not adequate for obtaining sufficient geometric accuracy. In this research, the geometric nature, especially the major distortions, of the CAMS data has been described. An analytical step-by-step geometric preprocessing has been utilized to deal with the potential high frequency distortions of the CAMS data. A generic sensor-independent photogrammetric model has been developed for the ortho-rectification of the CAMS data. Three generalized kernel classes and directional elliptical basis have been formulated into a rectification model of summation of multisurface functions, which is a significant extension to the traditional radial basis functions. The preprocessing mechanism has been fully incorporated into the polynomial, the triangle-based finite element analysis as well as the summation of multisurface functions. While the multisurface functions and the finite element analysis have the characteristics of localization, piecewise logic has been applied to the polynomial and photogrammetric methods, which can produce significant accuracy improvement over the global approach. A software module has been implemented with full

  6. Complementary and Alternative Medicine (CAM) Treatments and Pediatric Psychopharmacology

    Science.gov (United States)

    Rey, Joseph M.; Walter, Garry; Soh, Nerissa

    2008-01-01

    Children and adolescents often use complementary and alternative medicine (CAM) treatments outside their indications, particularly to lose weight. Some of the herbal remedies and dietary supplements that may of relevance for psychopharmacological practice are discussed with respect to CAM treatments.

  7. Complementary and Alternative Medicine (CAM) use by Malaysian oncology patients.

    Science.gov (United States)

    Farooqui, Maryam; Hassali, Mohamed Azmi; Abdul Shatar, Aishah Knight; Shafie, Asrul Akmal; Seang, Tan Boon; Farooqui, Muhammad Aslam

    2012-05-01

    The current study sought to evaluate Malaysian oncology patients' decision making about the use of Complementary and Alternative Medicine (CAM) for the management of their care. Patients were interviewed across three major Malaysian ethnic groups, Malay, Chinese and Indian. Thematic content analysis identified four central themes: Conceptualizing CAM, the decision making process; rationale given for selecting or rejecting CAM and barriers to CAM use. Participants generally used the term 'traditional medicine', referred to locally as 'ubat kampung', meaning medicine derived from 'local traditions'. Mixed reactions were shown concerning the effectiveness of CAM to cure cancer and the slow progression of CAM results and treatment costs were cited as major barriers to CAM use. Concerns regarding safety and efficacy of CAM in ameliorating cancer as well as potential interactions with conventional therapies highlighted the importance of patients' knowledge about cancer treatments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Complementary and Alternative Medicine (CAM) Treatments and Pediatric Psychopharmacology

    Science.gov (United States)

    Rey, Joseph M.; Walter, Garry; Soh, Nerissa

    2008-01-01

    Children and adolescents often use complementary and alternative medicine (CAM) treatments outside their indications, particularly to lose weight. Some of the herbal remedies and dietary supplements that may of relevance for psychopharmacological practice are discussed with respect to CAM treatments.

  9. Thyroid Disease and Complementary and Alternative Medicine (CAM)

    Science.gov (United States)

    ... in Thyroid Disease Complementary and Alternative Medicine in Thyroid Disease (CAM) WHAT IS COMPLEMENTARY AND ALTERNATIVE MEDICINE ( ... medicine Vodun/Expiritism Ayurvedic medicine REASONS PATIENTS WITH THYROID CANCER/THYROID DISEASE CHOOSE CAM There are few ...

  10. Integrated design of cam mechanisms and servo-control systems

    Institute of Scientific and Technical Information of China (English)

    姚燕安[1; 颜鸿森[2; 张策[3; 邹慧君[4

    2000-01-01

    Traditionally, in a cam mechanism, the cam is driven by an actuator at a constant speed. The motion characteristics of the follower are determined once the cam profile is designed. This paper presents a novel theory named "integrated design of cam mechanisms and servo-control systems" whose basic idea is varying the input speed trajectory of the cam by a microcomputer-controlled servomotor to improve kinematic and dynamic characteristics of the follower system. The philosophy of the theory is developing superior machines by taking advantage of the flexibility of servo-control systems to compensate for disadvantages of rigid cam mechanisms. The systematic design criteria of the cam-servo-integrated system are developed and an approach based on optimal-control theory is presented for to select suitable cam speed functions, hence the basis of the theory is formed.

  11. DFM/CAPP/CAM System in a Concurrent Engineering Environment

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    In this paper the importance of DFM/CAPP/CAM system in Concurrent Engineering (CE) is discussed. Based on the analyses of the character of concurrent product design and manufacturing process design, the workflow of DFM/CAPP/CAM system in CE is given. DFM/CAPP/CAM theories, methods and functions are investigated in a delicate and all-round way, and are implemented in the developed DFM/CAPP/CAM system.

  12. CAD/CAM. High-Technology Training Module.

    Science.gov (United States)

    Zuleger, Robert

    This high technology training module is an advanced course on computer-assisted design/computer-assisted manufacturing (CAD/CAM) for grades 11 and 12. This unit, to be used with students in advanced drafting courses, introduces the concept of CAD/CAM. The content outline includes the following seven sections: (1) CAD/CAM software; (2) computer…

  13. Education and Training Packages for CAD/CAM.

    Science.gov (United States)

    Wright, I. C.

    1986-01-01

    Discusses educational efforts in the fields of Computer Assisted Design and Manufacturing (CAD/CAM). Describes two educational training initiatives underway in the United Kingdom, one of which is a resource materials package for teachers of CAD/CAM at the undergraduate level, and the other a training course for managers of CAD/CAM systems. (TW)

  14. Current techniques in CAD/CAM denture fabrication.

    Science.gov (United States)

    Baba, Nadim Z; AlRumaih, Hamad S; Goodacre, Brian J; Goodacre, Charles J

    2016-01-01

    Recently, the use of computer-aided design/computer-aided manufacturing (CAD/CAM) to produce complete dentures has seen exponential growth in the dental market, and the number of commercially available CAD/CAM denture systems grows every year. The purpose of this article is to describe the clinical and laboratory procedures of 5 CAD/CAM denture systems.

  15. Bridging CAM practice and research: teaching CAM practitioners about research methodology.

    Science.gov (United States)

    Zick, Suzanna M; Benn, Rita

    2004-01-01

    The National Institutes of Health (NIH) is continuing to provide funds directed to support research in complementary and alternative medicine (CAM). CAM providers typically have insufficient knowledge of scientific language or research methodology to develop rigorous proposals. Their ability to contribute meaningfully as advisors, teachers, or research partners in academic settings, is hence limited. To address this issue, we have developed and implemented a 7-week course designed to teach community-based CAM providers: (1) to understand scientific terminology, research design and grantsmanship; (2) to critically evaluate the research literature; and (3) to design pilot studies in areas of their interest. In this article, we describe the recruitment process for selecting course participants, the course design and instructional process and the evaluation results based on qualitative and quantitative methodology. We offer suggestions for developing training opportunities both at the local and national level that would increase the expertise of CAM providers in participating and seeking funded research.

  16. Faint stars and OmegaCAM

    NARCIS (Netherlands)

    Kuijken, K; Cristiani, S; Renzini, A; Williams, RE

    2001-01-01

    OmegaCAM will be the wide-field imager on the VLT Survey Telescope. In this contribution I present applications of this instrument to the study of faint stellar populations. Two projects are highlighted: a proper motion study to uncover the galactic halo population, and a microlensing study towards

  17. Faint stars and OmegaCAM

    NARCIS (Netherlands)

    Kuijken, K; Cristiani, S; Renzini, A; Williams, RE

    2001-01-01

    OmegaCAM will be the wide-field imager on the VLT Survey Telescope. In this contribution I present applications of this instrument to the study of faint stellar populations. Two projects are highlighted: a proper motion study to uncover the galactic halo population, and a microlensing study towards

  18. EpCAM-targeted induction of apoptosis

    NARCIS (Netherlands)

    Bremer, Edwin; Helfrich, Wijnand

    2008-01-01

    EpCAM is a well-established pancarcinoma-associated target antigen that has been used in a variety of therapeutic approaches. Of particular appeal are those strategies that aim to retarget and locally activate immune effector mechanisms involving apoptosis. Cancer cells typically employ various stra

  19. Development of the two-part pattern during regeneration of the head in hydra

    DEFF Research Database (Denmark)

    Bode, Matthias; Awad, T A; Koizumi, O;

    1988-01-01

    The head of a hydra is composed of two parts, a domed hypostome with a mouth at the top and a ring of tentacles below. When animals are decapitated a new head regenerates. During the process of regeneration the apical tip passes through a transient stage in which it exhibits tentacle...... began evaginating in a ring, both the TS-19 antigen and RLI+ ganglion cells gradually disappeared from the presumptive hypostome area and RLI+ sensory cells appeared at the apex. By tracking tissue movements during morphogenesis it became clear that the apical cap, in which these changes took place, did...... not undergo tissue turnover. The implications of this tentacle-like stage for patterning the two-part head are discussed....

  20. Complementary and alternative medicine use of women with breast cancer : Self-help CAM attracts other women than guided CAM therapies

    NARCIS (Netherlands)

    Lo-Fo-Wong, Deborah N. N.; Ranchor, Adelita V.; de Haes, Hanneke C. J. M.; Sprangers, Mirjam A. G.; Henselmans, Inge

    2012-01-01

    Objective: Examine stability of use of complementary and alternative medicine (CAM) of breast cancer patients, reasons for CAM use, and sociodemographic, clinical, and psychological predictors of CAM use. Methods: CAM use was assessed after adjuvant therapy and six months later. Following the CAM He

  1. Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms

    CERN Document Server

    Williams, J J

    2013-01-01

    Modern design methods of Automotive Cam Design require the computation of a range of parameters. This book provides a logical sequence of steps for the derivation of the relevant equations from first principles, for the more widely used cam mechanisms. Although originally derived for use in high performance engines, this work is equally applicable to the design of mass produced automotive and other internal combustion engines.   Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms provides the equations necessary for the design of cam lift curves with an associated smooth acceleration curve. The equations are derived for the kinematics and kinetics of all the mechanisms considered, together with those for cam curvature and oil entrainment velocity. This permits the cam shape, all loads, and contact stresses to be evaluated, and the relevant tribology to be assessed. The effects of asymmetry on the manufacture of cams for finger follower and offset translating curved followers is ...

  2. Research on the processing speed of cam grinding

    Science.gov (United States)

    Peng, Baoying; Han, Qiushi

    2011-05-01

    Cam Grinding is a special kind of non-circular machining. The processing speed of cam grinding has a major influence on cam machining precision. In this paper, decomposed the X-axis feed speed and C-axis velocity by the tangential speed and normal speed in accordance with the curvature circle at the point of cam profile grinding. Proposed the cam grinding processing speed model and linear velocity calculation formula, the processing experiment on the CNC camshaft grinding machine results show that the cam grinding speed model is correct. Constant angular speed grinding and constant linear speed grinding are analyzed respectively, which provides a theoretical basis for cam grinding processing speed optimization.

  3. Z Cam Stars in the Twenty-First Century

    Science.gov (United States)

    Simonsen, M.; Boyd, D.; Goff, W.; Krajci, T.; Menzies, K.; Otero, S.; Padovan, S.; Poyner, G.; Roe, J.; Sabo, R.; Sjoberg, G.; Staels, B.; Stubbings, R.; Toone, J.; Wils, P.

    2014-05-01

    Z Cam (UGZ) stars are a small subset of dwarf novae that exhibit standstills in their light curves. Most modern literature and catalogs of cataclysmic variables quote the number of known Z Cams to be on the order of thirty or so systems. After a four-year observing campaign and an exhaustive examination of the data in the AAVSO International Database (AID) we have trimmed that number by a third. One of the reasons for the misclassification of some systems is the fact that the definition of what a Z Cam is has changed over the last eighty-five years. This has caused many stars formerly assumed to be Z Cams or rumored to be Z Cams to be eliminated from the final list. In this paper we present the results of our investigation into sixty-five stars listed at one time or another in the literature as Z Cams or possible Z Cams.

  4. Much ado about two: reconsidering retransformation and the two-part model in health econometrics.

    Science.gov (United States)

    Mullahy, J

    1998-06-01

    In health economics applications involving outcomes (y) and covariates (x), it is often the case that the central inferential problems of interest involve E[y/x] and its associated partial effects or elasticities. Many such outcomes have two fundamental statistical properties: y > or = 0; and the outcome y = 0 is observed with sufficient frequency that the zeros cannot be ignored econometrically. This paper (1) describes circumstances where the standard two-part model with homoskedastic retransformation will fail to provide consistent inferences about important policy parameters; and (2) demonstrates some alternative approaches that are likely to prove helpful in applications.

  5. Physical activity versus cardiorespiratory fitness: two (partly) distinct components of cardiovascular health?

    Science.gov (United States)

    DeFina, Laura F; Haskell, William L; Willis, Benjamin L; Barlow, Carolyn E; Finley, Carrie E; Levine, Benjamin D; Cooper, Kenneth H

    2015-01-01

    Physical activity (PA) and cardiorespiratory fitness (CRF) both have inverse relationships to cardiovascular (CV) morbidity and mortality. Recent position papers and guidelines have identified the important role of both of these factors in CV health. The benefits of PA and CRF in the prevention of CV disease and risk factors are reviewed. In addition, assessment methodology and utilization in the research and clinical arenas are discussed. Finally, the benefits, methodology, and utilization are compared and contrasted to better understand the two (partly) distinct components and their impact on CV health.

  6. Formal Management of CAD/CAM Processes

    Science.gov (United States)

    Kohlhase, Michael; Lemburg, Johannes; Schröder, Lutz; Schulz, Ewaryst

    Systematic engineering design processes have many aspects in common with software engineering, with CAD/CAM objects replacing program code as the implementation stage of the development. They are, however, currently considerably less formal. We propose to draw on the mentioned similarities and transfer methods from software engineering to engineering design in order to enhance in particular the reliability and reusability of engineering processes. We lay out a vision of a document-oriented design process that integrates CAD/CAM documents with requirement specifications; as a first step towards supporting such a process, we present a tool that interfaces a CAD system with program verification workflows, thus allowing for completely formalised development strands within a semi-formal methodology.

  7. CAM/LIFTER forces and friction

    Science.gov (United States)

    Gabbey, D. J.; Lee, J.; Patterson, D. J.

    1992-02-01

    This report details the procedures used to measure the cam/lifter forces and friction. The present effort employed a Cummins LTA-10, and focuses on measurements and dynamic modeling of the injector train. The program was sponsored by the US Department of Energy in support of advanced diesel engine technology. The injector train was instrumented to record the instantaneous roller speed, roller pin friction torque, pushrod force, injector link force, and cam speed. These measurements, together with lift profiles for pushrod and injector link displacement, enabled the friction work loss in the injector train to be determined. Other significant design criteria such as camshaft roller follower slippage and maximum loads on components were also determined. Future efforts will concentrate on the dynamic model, with tests run as required for correlation.

  8. CAM and Post-Traumatic Stress Disorder

    Directory of Open Access Journals (Sweden)

    Alex Hankey

    2007-01-01

    Full Text Available In the form of the Transcendental Meditation program CAM offers a method of eliminating deep-rooted stress, the efficacy of which has been demonstrated in several related studies. Any discussion of CAM and post-traumatic stress disorder should include a study of its application to Vietnam War Veterans in which improvements were observed on all variables, and several participants were able to return to work after several years of being unable to hold a job. The intervention has been studied for its impact on brain and autonomic nervous system function. It has been found to be highly effective against other stress-related conditions such as hypertension, and to improve brain coherence—a measure of effective brain function. It should be considered a possible ‘new and improved mode of treatment’ for PTSD, and further studies of its application made.

  9. CAD/CAM-assisted breast reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Melchels, Ferry; Hutmacher, Dietmar Werner [Institute of Health and Biomedical Innovation, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, QLD 4059 (Australia); Wiggenhauser, Paul Severin; Schantz, Jan-Thorsten [Department of Plastic and Hand Surgery, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Strasse 22, 81675 Munich (Germany); Warne, David; Barry, Mark [High Performance Computing and Research Support, Queensland University of Technology, Gardens Point Road, Brisbane, QLD 4000 (Australia); Ong, Fook Rhu; Chong, Woon Shin, E-mail: Dietmar.Hutmacher@qut.edu.au, E-mail: jtschantz@lrz.tu-muenchen.de [Singapore Polytechnic, 500 Dover Road, 139651 Singapore (Singapore)

    2011-09-15

    The application of computer-aided design and manufacturing (CAD/CAM) techniques in the clinic is growing slowly but steadily. The ability to build patient-specific models based on medical imaging data offers major potential. In this work we report on the feasibility of employing laser scanning with CAD/CAM techniques to aid in breast reconstruction. A patient was imaged with laser scanning, an economical and facile method for creating an accurate digital representation of the breasts and surrounding tissues. The obtained model was used to fabricate a customized mould that was employed as an intra-operative aid for the surgeon performing autologous tissue reconstruction of the breast removed due to cancer. Furthermore, a solid breast model was derived from the imaged data and digitally processed for the fabrication of customized scaffolds for breast tissue engineering. To this end, a novel generic algorithm for creating porosity within a solid model was developed, using a finite element model as intermediate.

  10. Chiropractic and CAM Utilization: A Descriptive Review

    OpenAIRE

    Meeker William C; Lawrence Dana J

    2007-01-01

    Abstract Objective To conduct a descriptive review of the scientific literature examining use rates of modalities and procedures used by CAM clinicians to manage chronic LBP and other conditions Data Sources A literature of PubMed and MANTIS was performed using the key terms Chiropractic; Low Back Pain; Utilization Rate; Use Rate; Complementary and Alternative Medicine; and Health Services in various combinations. Data Selection A total of 137 papers were selected, based upon including inform...

  11. An investigation of cam-roller mechanism applied in sphere cam engine

    Institute of Scientific and Technical Information of China (English)

    张雷; 潘存云; 徐小军; 徐海军; 张正洲

    2016-01-01

    As an alternative power source for hybrid electrical vehicle(HEV), electric generating system(EGS) driven by sphere cam engine(SCE) is said to own higher power density and integration. In this work, the structure and working principle of EGS were introduced, based on which the advantages of EGS were displayed. The profile of sphere cam was achieved after the desired motion of piston was given. After establishing the dynamic model of power transmission mechanism, the characteristics of cam-roller mechanism were studied. The results show that the optimal cam profile of SCE is a sinusoid curve which has two peaks and two valleys and a mean pressure angle of 47.19°. Because of the special cam shape, the trace of end surface center of piston is an eight-shape curve on a specific sphere surface. SCE running at speed of 3000 r/min can generate the power of 33.81 kW, which could satisfy the need of HEVs. However, the force between cylinder and piston skirt caused by Coriolis acceleration can reach up to 1182 N, which leads to serious wear between cylinder liner and piston skirt and may shorten the lifespan of SCE.

  12. Modeled hydraulic redistribution in tree-grass, CAM-grass, and tree-CAM associations: the implications of crassulacean acid metabolism (CAM).

    Science.gov (United States)

    Yu, Kailiang; Foster, Adrianna

    2016-04-01

    Past studies have largely focused on hydraulic redistribution (HR) in trees, shrubs, and grasses, and recognized its role in interspecies interactions. HR in plants that conduct crassulacean acid metabolism (CAM), however, remains poorly investigated, as does the effect of HR on transpiration in different vegetation associations (i.e., tree-grass, CAM-grass, and tree-CAM associations). We have developed a mechanistic model to investigate the net direction and magnitude of HR at the patch scale for tree-grass, CAM-grass, and tree-CAM associations at the growing season to yearly timescale. The modeling results show that deep-rooted CAM plants in CAM-grass associations could perform hydraulic lift at a higher rate than trees in tree-grass associations in a relatively wet environment, as explained by a significant increase in grass transpiration rate in the shallow soil layer, balancing a lower transpiration rate by CAM plants. By comparison, trees in tree-CAM associations may perform hydraulic descent at a higher rate than those in tree-grass associations in a dry environment. Model simulations also show that hydraulic lift increases the transpiration of shallow-rooted plants, while hydraulic descent increases that of deep-rooted plants. CAM plants transpire during the night and thus perform HR during the day. Based on these model simulations, we suggest that the ability of CAM plants to perform HR at a higher rate may have different effects on the surrounding plant community than those of plants with C3 or C4 photosynthetic pathways (i.e., diurnal transpiration).

  13. The NectarCAM camera project

    CERN Document Server

    Glicenstein, J-F; Barrio, J-A; Blanch, O; Boix, J; Bolmont, J; Boutonnet, C; Cazaux, S; Chabanne, E; Champion, C; Chateau, F; Colonges, S; Corona, P; Couturier, S; Courty, B; Delagnes, E; Delgado, C; Ernenwein, J-P; Fegan, S; Ferreira, O; Fesquet, M; Fontaine, G; Fouque, N; Henault, F; Gascón, D; Herranz, D; Hermel, R; Hoffmann, D; Houles, J; Karkar, S; Khelifi, B; Knödlseder, J; Martinez, G; Lacombe, K; Lamanna, G; LeFlour, T; Lopez-Coto, R; Louis, F; Mathieu, A; Moulin, E; Nayman, P; Nunio, F; Olive, J-F; Panazol, J-L; Petrucci, P-O; Punch, M; Prast, J; Ramon, P; Riallot, M; Ribó, M; Rosier-Lees, S; Sanuy, A; Siero, J; Tavernet, J-P; Tejedor, L A; Toussenel, F; Vasileiadis, G; Voisin, V; Waegebert, V; Zurbach, C

    2013-01-01

    In the framework of the next generation of Cherenkov telescopes, the Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium size telescopes covering the central energy range of 100 GeV to 30 TeV. NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view, FoV) in order to image atmospheric Cherenkov showers by measuring the charge deposited within a few nanoseconds time-window. It will have additional features like the capacity to record the full waveform with GHz sampling for every pixel and to measure event times with nanosecond accuracy. An array of a few tens of medium size telescopes, equipped with NectarCAMs, will achieve up to a factor of ten improvement in sensitivity over existing instruments in the energy range of 100 GeV to 10 TeV. The camera is made of roughly 250 independent read-out modules, each composed of seven photo-multipliers, with their associated high voltage base and control, a read-out board and a multi-service backplane board. The read-out b...

  14. EpCAM-targeted induction of apoptosis.

    Science.gov (United States)

    Bremer, Edwin; Helfrich, Wijnand

    2008-05-01

    EpCAM is a well-established pancarcinoma-associated target antigen that has been used in a variety of therapeutic approaches. Of particular appeal are those strategies that aim to retarget and locally activate immune effector mechanisms involving apoptosis. Cancer cells typically employ various strategies to evade recognition and elimination by immune effector cells, including low or absent expression of MHCI molecules and active elimination of tumor infiltrating immune cells. In addition, cancer cells show an increased resistance towards endogenous pro-apoptotic stimuli due to aberrancies in their apoptotic machinery. However, compelling evidence indicates that cancer cells are often reliant on these molecular aberrations for continued cell survival. This pivotal role of immune evasion and apoptosis resistance has fueled the quest for therapeutic strategies that can selectively retarget and reactivate immune effector cells or molecules, whereby the balance of cellular fate of cancer cells is selectively tipped towards apoptosis. Here we review and discuss the perspectives for EpCAM-targeted apoptosis induction in cancer by EpCAM-selective bispecific antibodies and TRAIL fusion proteins.

  15. Two-part silicone mold. A new tool for flexible ureteroscopy surgical training

    Directory of Open Access Journals (Sweden)

    Bruno Marroig

    Full Text Available ABSTRACT Introduction and objectives: Flexible ureteroscopy is a common procedure nowadays. Most of the training programs use virtual reality simulators. The aim of this study was to standardize the building of a three-dimensional silicone mold (cavity of the collecting system, on the basis of polyester resin endocasts, which can be used in surgical training programs. Materials and Methods: A yellow polyester resin was injected into the ureter to fill the collecting system of 24 cadaveric fresh human kidneys. After setting off the resin, the kidneys were immersed in hydrochloric acid until total corrosion of the organic matter was achieved and the collecting system endocasts obtained. The endocasts were used to prepare white color two-part silicone molds, which after endocasts withdrawn, enabled a ureteroscope insertion into the collecting system molds (cavities. Also, the minor calices were painted with different colors in order to map the access to the different caliceal groups. The cost of the materials used in the molds is $30.00 and two days are needed to build them. Results: Flexible ureteroscope could be inserted into all molds and the entire collecting system could be examined. Since some anatomical features, as infundular length, acute angle, and perpendicular minor calices may difficult the access to some minor calices, especially in the lower caliceal group, surgical training in models leads to better surgical results. Conclusions: The two-part silicone mold is feasible, cheap and allows its use for flexible ureteroscopy surgical training.

  16. JunoCam's Imaging of Jupiter

    Science.gov (United States)

    Orton, Glenn; Hansen, Candice; Momary, Thomas; Caplinger, Michael; Ravine, Michael; Atreya, Sushil; Ingersoll, Andrew; Bolton, Scott; Rogers, John; Eichstaedt, Gerald

    2017-04-01

    Juno's visible imager, JunoCam, is a wide-angle camera (58° field of view) with 4 color filters: red, green and blue (RGB) and methane at 889 nm, designed for optimal imaging of Jupiter's poles. Juno's elliptical polar orbit offers unique views of Jupiter's polar regions with spatial scales as good as 50 km/pixel. At closest approach ("perijove") the images have spatial scale down to ˜3 km/pixel. As a push-frame imager on a rotating spacecraft, JunoCam uses time-delayed integration to take advantage of the spacecraft spin to extend integration time to increase signal. Images of Jupiter's poles reveal a largely uncharted region of Jupiter, as nearly all earlier spacecraft except Pioneer 11 have orbited or flown by close to the equatorial plane. Poleward of 64-68° planetocentric latitude, Jupiter's familiar east-west banded structure breaks down. Several types of discrete features appear on a darker, bluish-cast background. Clusters of circular cyclonic spirals are found immediately around the north and south poles. Oval-shaped features are also present, ranging in size down to JunoCam's resolution limits. The largest and brightest features usually have chaotic shapes; animations over ˜1 hour can reveal cyclonic motion in them. Narrow linear features traverse tens of degrees of longitude and are not confined in latitude. JunoCam also detected optically thin clouds or hazes that are illuminated beyond the nightside ˜1-bar terminator; one of these detected at Perijove lay some 3 scale heights above the main cloud deck. Tests have been made to detect the aurora and lightning. Most close-up images of Jupiter have been acquired at lower latitudes within 2 hours of closest approach. These images aid in understanding the data collected by other instruments on Juno that probe deeper in the atmosphere. When Jupiter was too close to the sun for ground-based observers to collect data between perijoves 1 and 2, JunoCam took a sequence of routine images to monitor large

  17. Fit of CAD/CAM implant frameworks: a comprehensive review.

    Science.gov (United States)

    Abduo, Jaafar

    2014-12-01

    Computer-aided design and computer-aided manufacturing (CAD/CAM) is a strongly emerging prosthesis fabrication method for implant dentistry. Currently, CAD/CAM allows the construction of implant frameworks from different materials. This review evaluates the literature pertaining to the precision fit of fixed implant frameworks fabricated by CAD/CAM. Following a comprehensive electronic search through PubMed (MEDLINE), 14 relevant articles were identified. The results indicate that the precision fit of CAD/CAM frameworks exceeded the fit of the 1-piece cast frameworks and laser-welded frameworks. A similar fit was observed for CAD/CAM frameworks and bonding of the framework body to prefabricated cylinders. The influence of CAD/CAM materials on the fit of a framework is minimal.

  18. New Classification Methods for Hiding Information into Two Parts: Multimedia Files and Non Multimedia Files

    CERN Document Server

    Alanazi, Hamdan O; Zaidan, B B; Jalab, Hamid A; AL-Ani, Zaidoon Kh

    2010-01-01

    With the rapid development of various multimedia technologies, more and more multimedia data are generated and transmitted in the medical, commercial, and military fields, which may include some sensitive information which should not be accessed by or can only be partially exposed to the general users. Therefore, security and privacy has become an important, Another problem with digital document and video is that undetectable modifications can be made with very simple and widely available equipment, which put the digital material for evidential purposes under question .With the large flood of information and the development of the digital format Information hiding considers one of the techniques which used to protect the important information. The main goals for this paper, provides a general overview of the New Classification Methods for Hiding Information into Two Parts: Multimedia Files and Non Multimedia Files.

  19. A panorama of dental CAD/CAM restorative systems.

    Science.gov (United States)

    Liu, Perng-Ru

    2005-07-01

    In the last 2 decades, exciting new developments in dental materials and computer technology have led to the success of contemporary dental computer-aided design/computer-aided manufacturing (CAD/CAM) technology. Several highly sophisticated chairside and laboratory CAD/CAM systems have been introduced or are under development. This article provides an overview of the development of various CAD/CAM systems. Operational components, methodologies, and restorative materials used with common CAD/CAM systems are discussed. Research data and clinical studies are presented to substantiate the clinical performance of these systems.

  20. Panorama of dental CAD/CAM restorative systems.

    Science.gov (United States)

    Liu, Perng-Ru; Essig, Milton E

    2008-10-01

    In the past two decades, exciting new developments in dental materials and computer technology have led to the success of contemporary dental computer-aided design/computer-aided manufacture (CAD/CAM) technology. Several highly sophisticated in-office and laboratory CAD/CAM systems have been introduced or are under development. This article provides an overview of the development of various CAD/CAM systems. Operational components, methodologies, and restorative materials used with common CAD/CAM systems are discussed. Research data and clinical studies are presented to substantiate the clinical performance of these systems.

  1. Optical integration of CAD/CAM materials.

    Science.gov (United States)

    Güth, Jan-Frederik; Magne, Pascal

    The optical integration (OI) of monolithic CAD/CAM materials under 4 illuminations was evaluated using a standardized and clinically relevant method. Eighteen inlays were manufactured and placed (glycerin gel). Standardized photos were taken under 4 illuminations (neutral white light direct and indirect illumination, cross-polarized light, fluorescent light). Six evaluators defined the optical integration score (OIS) as the "visibility" of the restoration (0 = worst OI, 4 = optimal OI). The intact tooth served as control. The null hypothesis was that different illuminations did not influence the OI of CAD/CAM inlays. One-way ANOVA, followed by Scheffe's post hoc, was applied (P = 0.05). Neutral light direct illumination: OIS between 2.67 (IPS e.max CAD LT A1, ENAMIC A1) and 3.83 (IPS e.max CAD HT A1) with a mean of 3.28 (± 0.339). Indirect illumination: OIS from 1.00 (Paradigm MZ100 A1) to 2.41 (ENAMIC A1) with a mean of 1.88 (± 0.598). Fluorescent light: OIS between 0.75 and 3.25 with a mean of 1.67 (± 1.025). ENAMIC and VITA BLOCS Mark II showed the best optical integration in fluorescence. IPS e.max CAD, Paradigm MZ 100 demonstrated low fluorescence; Lava Ultimate high fluorescence. OI was influenced by different illumination. A simple method accessible to clinicians for additional evaluation of CAD/CAM materials in daily practice is presented. All materials showed excellent OI under direct illumination with neutral white light. The most pronounced differences in optical integration between tooth and evaluated materials were observed under fluorescent light.

  2. Special Section: Complementary and Alternative Medicine (CAM): Low Back Pain and CAM

    Science.gov (United States)

    ... back, he has used conventional and complementary and alternative medicine (CAM) approaches, including regular visits to the chiropractor and massage therapist to address his pain. "I'm looking for something so that I don't ... with other alternative and traditional therapies to help them resume normal ...

  3. Ab initio atom-atom potentials using CamCASP: Application to pyridine

    CERN Document Server

    Misquitta, Alston J

    2015-01-01

    In Part I of this two-part investigation we described a methodology for the development of robust, analytic, many-body atom-atom potentials for small organic molecules from first principles. Here we demonstrate how these theoretical ideas, which are implemented in the CamCASP suite of programs, can be used to develop a series of many-body potentials for the pyridine system. Even the simplest of these potentials exhibit r.m.s. errors of only about 0.5kJ mol$^{-1}$, significantly surpassing the best empirical potentials. Further, the functional form can be made systematically more elaborate so as to improve the accuracy without a significant increase in the human-time spent in their generation. We investigate the effects of anisotropy, rank of multipoles, and choice of polarizability and dispersion models.

  4. Ab initio atom-atom potentials using CamCASP: Theory

    CERN Document Server

    Misquitta, Alston J

    2015-01-01

    Creating accurate, analytic atom-atom potentials for small organic molecules from first principles can be a time-consuming and computationally intensive task, particularly if we also require them to include explicit polarization terms, which are essential in many systems. In this first part of a two-part investigation, we describe how the CamCASP suite of programs can be used to generate such potentials using some of the most accurate electronic structure methods practically applicable. In particular, we introduce a novel approach to determine the short-range anisotropy parameters by a robust method based on the iterated stockholder atoms approach. In the second part of this work we will apply these methods to develop a series of many-body potentials for the pyridine system.

  5. Subaru Prime Focus Camera -- Suprime-Cam --

    CERN Document Server

    Miyazaki, S; Sekiguchi, M; Okamura, S; Doi, M; Furusawa, H; Hamabe, M; Imi, K; Kimura, M; Nakata, F; Okada, N; Ouchi, M; Shimasaku, K; Yagi, M; Yasuda, N; Miyazaki, Satoshi; Komiyama, Yutaka; Sekiguchi, Maki; Okamura, Sadanori; Doi, Mamoru; Furusawa, Hisanori; Hamabe, Masaru; Imi, Katsumi; Kimura, Masahiki; Nakata, Fumiaki; Okada, Norio; Ouchi, Masami; Shimasaku, Kazuhiro; Yagi, Masafumi; Yasuda, Naoki

    2002-01-01

    We have built an 80 mega pixels (10240 X 8192) mosaic CCD camera, called Suprime-Cam, for the wide field prime focus of the 8.2 m Subaru telescope. Suprime-Cam covers a field of view 34 arcmin X 27 arcmin, a unique facility among the the 8 - 10 m class telescopes, with a resolution of 0.202 arcsec per pixel. The focal plane consists of ten high-resistivity 2kX4k CCDs developed by MIT Lincoln Laboratory and these are cooled by a large stirling cycle cooler. The CCD readout electronics are developed originally by our group (M-Front & Messia-III) and the system is designed scalable that allows multiple read-out of tens of CCDs. It takes 50 seconds to readout entire arrays. We have designed a filter exchange mechanism of jukebox type that can holds up to ten large filters (205 X 170 X 15 mm^3). The wide field corrector is basically a three-lens Wynne-type but has a new type of atmospheric dispersion corrector. The corrector provides flat focal plane and un-vignetted field of view of 30 arcmin in diameter. Ach...

  6. CAD/CAM: Practical and Persuasive in Canadian Schools

    Science.gov (United States)

    Willms, Ed

    2007-01-01

    Chances are that many high school students would not know how to use drafting instruments, but some might want to gain competence in computer-assisted design (CAD) and possibly computer-assisted manufacturing (CAM). These students are often attracted to tech courses by the availability of CAD/CAM instructions, and many go on to impress employers…

  7. A systematic review of CAD/CAM fit restoration evaluations.

    Science.gov (United States)

    Boitelle, P; Mawussi, B; Tapie, L; Fromentin, O

    2014-11-01

    The evolution and development of CAD/CAM systems have led to the production of prosthetic reconstructions by going beyond the use of traditional techniques. Precision adjustment of prosthetic elements is considered essential to ensure sustainable restoration and dental preparation. The purpose of this article was to summarise the current literature on the fitting quality of fixed prostheses obtained by CAD/CAM technology.

  8. EpCAM : Structure and function in health and disease

    NARCIS (Netherlands)

    Schnell, Ulrike; Cirulli, Vincenzo; Giepmans, Ben N. G.

    2013-01-01

    Injection of tumor cells in mice more than 30 years ago resulted in the discovery of an epithelial antigen, later defined as a cell adhesion molecule (EpCAM). Although EpCAM has since evoked significant interest as a target in cancer therapy, mechanistic insights on the functions of this glycoprotei

  9. Mechanics of post-cam engagement during simulated dynamic activity.

    Science.gov (United States)

    Fitzpatrick, Clare K; Clary, Chadd W; Cyr, Adam J; Maletsky, Lorin P; Rullkoetter, Paul J

    2013-09-01

    Posterior-stabilized (PS) total knee arthroplasty (TKA) components employ a tibial post and femoral cam mechanism to guide anteroposterior knee motion in lieu of the posterior cruciate ligament. Some PS TKA patients report a clicking sensation when the post and cam engage, while severe wear and fracture of the post; we hypothesize that these complications are associated with excessive impact velocity at engagement. We evaluated the effect of implant design on engagement dynamics of the post-cam mechanism and resulting polyethylene stresses during dynamic activity. In vitro simulation of a knee bend activity was performed for four cadaveric specimens implanted with PS TKA components. Post-cam engagement velocity and flexion angle at initial contact were determined. The experimental data were used to validate computational predictions of PS mechanics using the same loading conditions. A lower limb model was subsequently utilized to compare engagement mechanics of eight TKA designs, relating differences between implants to geometric design features. Flexion angle and post-cam velocity at engagement demonstrated considerable ranges among designs (23°-89°, and 0.05-0.22 mm/°, respectively). Post-cam velocity was correlated (r = 0.89) with tibiofemoral condylar design features. Condylar geometry, in addition to post-cam geometry, played a significant role in minimizing engagement velocity and forces and stresses in the post. This analysis guides selection and design of PS implants that facilitate smooth post-cam engagement and reduce edge loading of the post.

  10. UY Puppis A New Anomalous Z Cam Type Dwarf Nova

    CERN Document Server

    Stubbings, Rod

    2016-01-01

    The defining characteristic of Z Cam stars are standstills in their light curves. Some Z Cams exhibit atypical behaviour by going into outburst from a standstill. It has previously been suggested that UY Pup had been a Z Cam star, but it was ruled out due to its long-term light curve. However, in December 2015 UY Pup went into outburst and unexpectedly entered into a short standstill instead of returning to quiescence. Furthermore, UY Pup exhibited additional unusual behaviour with two outbursts detected during its standstill. After this standstill UY Pup made a brief excursion to a quiescence state and slowly rose to a longer and well-defined standstill, where it again went into another outburst. Through comparative analysis, researching and observational data of UY Pup it is evident and thus concluded that it is indeed a Z Cam star, in which renders it to be one of only four known anomalous Z Cam stars.

  11. Colour stainability of indirect CAD-CAM processed composites vs. conventionally laboratory processed composites after immersion in staining solutions.

    Science.gov (United States)

    Arocha, Mariana A; Basilio, Juan; Llopis, Jaume; Di Bella, Enrico; Roig, Miguel; Ardu, Stefano; Mayoral, Juan R

    2014-07-01

    The aim of this study was to determine, by using a spectrophotometer device, the colour stainability of two indirect CAD/CAM processed composites in comparison with two conventionally laboratory-processed composites after being immersed 4 weeks in staining solutions such as coffee, black tea and red wine, using distilled water as control group. Two indirect CAD/CAM composites (Lava Ultimate and Paradigm MZ100) and two conventionally laboratory-processed composites (SR Adoro and Premise Indirect) of shade A2 were selected (160 disc samples). Colour stainability was measured after 4 weeks of immersion in three staining solutions (black tea, coffee, red wine) and distilled water. Specimen's colour was measured each week by means of a spectrophotometer (CIE L*a*b* system). Statistical analysis was carried out performing repeated ANOVA measurements and Tukey's HSD test to evaluate differences in ΔE00 measurements between groups; the interactions among composites, staining solutions and time duration were also evaluated. All materials showed significant discoloration (pred wine, whereas black tea showed the lowest one. Indirect laboratory-processed resin composites showed the highest colour stability compared with CAD/CAM resin blocks. CAD/CAM processed composites immersed in staining solutions showed lower colour stability when compared to conventionally laboratory-processed resin composites. The demand for CAD/CAM restorations has been increasing; however, colour stainability for such material has been insufficiently studied. Moreover, this has not been performed comparing CAD/CAM processed composites versus laboratory-processed indirect composites by immersing in staining solutions for long immersion periods. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Treatment Preferences for CAM in Children with Chronic Pain

    Directory of Open Access Journals (Sweden)

    Jennie C. I. Tsao

    2007-01-01

    Full Text Available CAM therapies have become increasingly popular in pediatric populations. Yet, little is known about children's preferences for CAM. This study examined treatment preferences in chronic pediatric pain patients offered a choice of CAM therapies for their pain. Participants were 129 children (94 girls (mean age = 14.5 years ± 2.4; range = 8–18 years presenting at a multidisciplinary, tertiary clinic specializing in pediatric chronic pain. Bivariate and multivariate analyses were used to examine the relationships between CAM treatment preferences and patient's sociodemographic and clinical characteristics, as well as their self-reported level of functioning. Over 60% of patients elected to try at least one CAM approach for pain. The most popular CAM therapies were biofeedback, yoga and hypnosis; the least popular were art therapy and energy healing, with craniosacral, acupuncture and massage being intermediate. Patients with a diagnosis of fibromyalgia (80% were the most likely to try CAM versus those with other pain diagnoses. In multivariate analyses, pain duration emerged as a significant predictor of CAM preferences. For mind-based approaches (i.e. hypnosis, biofeedback and art therapy, pain duration and limitations in family activities were both significant predictors. When given a choice of CAM therapies, this sample of children with chronic pain, irrespective of pain diagnosis, preferred non-invasive approaches that enhanced relaxation and increased somatic control. Longer duration of pain and greater impairment in functioning, particularly during family activities increased the likelihood that such patients agreed to engage in CAM treatments, especially those that were categorized as mind-based modalities.

  13. Treatment Preferences for CAM in children with chronic pain.

    Science.gov (United States)

    Tsao, Jennie C I; Meldrum, Marcia; Kim, Su C; Jacob, Margaret C; Zeltzer, Lonnie K

    2007-09-01

    CAM therapies have become increasingly popular in pediatric populations. Yet, little is known about children's preferences for CAM. This study examined treatment preferences in chronic pediatric pain patients offered a choice of CAM therapies for their pain. Participants were 129 children (94 girls) (mean age = 14.5 years +/- 2.4; range = 8-18 years) presenting at a multidisciplinary, tertiary clinic specializing in pediatric chronic pain. Bivariate and multivariate analyses were used to examine the relationships between CAM treatment preferences and patient's sociodemographic and clinical characteristics, as well as their self-reported level of functioning. Over 60% of patients elected to try at least one CAM approach for pain. The most popular CAM therapies were biofeedback, yoga and hypnosis; the least popular were art therapy and energy healing, with craniosacral, acupuncture and massage being intermediate. Patients with a diagnosis of fibromyalgia (80%) were the most likely to try CAM versus those with other pain diagnoses. In multivariate analyses, pain duration emerged as a significant predictor of CAM preferences. For mind-based approaches (i.e. hypnosis, biofeedback and art therapy), pain duration and limitations in family activities were both significant predictors. When given a choice of CAM therapies, this sample of children with chronic pain, irrespective of pain diagnosis, preferred non-invasive approaches that enhanced relaxation and increased somatic control. Longer duration of pain and greater impairment in functioning, particularly during family activities increased the likelihood that such patients agreed to engage in CAM treatments, especially those that were categorized as mind-based modalities.

  14. Complementary and alternative medicine (CAM providers’ views of chronic low back pain patients’ expectations of CAM therapies: a qualitative study

    Directory of Open Access Journals (Sweden)

    Schafer Lisa M

    2012-11-01

    Full Text Available Abstract Background Some researchers think that patients with higher expectations for CAM therapies experience better outcomes and that enthusiastic providers can enhance treatment outcomes. This is in contrast to evidence suggesting conventional medical providers often reorient patient expectations to better match what providers believe to be realistic. However, there is a paucity of research on CAM providers’ views of their patients’ expectations regarding CAM therapy and the role of these expectations in patient outcomes. Methods To better understand how CAM providers view and respond to their patients’ expectations of a particular therapy, we conducted 32 semi-structured, qualitative interviews with acupuncturists, chiropractors, massage therapists and yoga instructors identified through convenience sampling. Interviews were recorded, transcribed and analyzed thematically using Atlas ti version 6.1. Results CAM providers reported that they attempt to ensure that their patients’ expectations are realistic. Providers indicated they manage their patients’ expectations in a number of domains— roles and responsibilities of providers and patients, treatment outcomes, timeframe for improvement, and treatment experience. Providers reported that patients’ expectations change over time and that they need to continually manage these expectations to enhance patient engagement and satisfaction with treatment. Conclusions Providers of four types of CAM therapies viewed patients’ expectations as an important component of their experiences with CAM therapy and indicated that they try to align patient expectations with reality. These findings suggest that CAM providers are similar in this respect to conventional medical providers.

  15. Machinability of CAD-CAM materials.

    Science.gov (United States)

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Examining the association between patient-centered communication and provider avoidance, CAM use, and CAM-use disclosure.

    Science.gov (United States)

    Faith, Jennifer; Thorburn, Sheryl; Tippens, Kimberly M

    2015-01-01

    Patients' perceptions of the quality of their relationships with health care providers may influence their health care-seeking behaviors and future interactions with providers, including use of conventional health care, use of complementary and alternative medicine (CAM), and disclosure of CAM use. The study examined the associations between perceived patient-centered communication and provider avoidance, CAM use, and CAM-use disclosure. This study used cross-sectional survey data from the Health Information National Trends Survey (HINTS) 3, a nationally representative survey of US adults collected between January 2008 and May 2008. Two questions asked about CAM use and CAM-use disclosure, and another asked about avoidance of doctors. For the independent variable, responses from 6 questions on patient-centered communication were averaged to create a scale score ranging from 1-4. The research team conducted multiple logistic regressions of the 3 primary outcome measures, adjusting for sociodemographic characteristics, presence or absence of a regular source of care, insurance status, frequency of visits to providers, and health status. All analyses were weighted to make the results representative of the US population aged ≥18 y. Approximately one-third of respondents (36%) had avoided seeing their doctors within the 12 mo prior to the survey. Approximately 24% had used CAM within the prior 12 mo, and 51.7% of CAM users had discussed their CAM use with their doctors. Higher levels of patient-centered communication were significantly associated with lower odds of provider avoidance (AOR=0.63; 95% CI=0.52, 0.76) and CAM use (AOR=0.60; 95% CI=0.46, 0.78) but were not associated with CAM-use disclosure. Findings suggest that patients may be more likely to avoid seeing their doctors and more likely to use CAM when they perceive low levels of patient-centered communication. Further research to understand the role of the characteristics of patient-provider relationships

  17. CAD/CAM systems available for the fabrication of crown and bridge restorations.

    Science.gov (United States)

    Miyazaki, T; Hotta, Y

    2011-06-01

    Dental biomaterials are widely used in all areas of routine dental practice. There are mainly two methods for their application. Firstly, dental biomaterials are placed into living tissues, such as teeth, to fill the space. Secondly, dental devices such as crown and bridge restorations and dentures are fabricated using various materials to restore the morphology and function of the dentition. Crown and bridge restorations are one of the main treatment methods used by general practitioners to achieve lifelike restoration of form and function. The recent introduction of osseointegrated implants has expanded the application of crown and bridge restorations for partially edentulous patients. Mechanical durability and precision fit are mandatory requirements for crowns and bridges. The development of various casting alloys and precise casting systems has contributed to the successful use of metal-based restorations. However, patient requests for more aesthetic and biologically 'safe' materials has led to an increased demand for metal-free restorations. There is also a growing demand to provide all-ceramic restorations more routinely. New materials such as highly sintered glass, polycrystalline alumina, zirconia based materials and adhesive monomers, will assist dentists to meet this demand. In addition, new fabrication systems combined with computer-assisted fabrication systems (dental CAD/CAM) and various networks are now available. Dental technology was centred on lost-wax casting technology but we now face a revolution in crown and bridge fabrication. This article reviews the history and recent status of dental CAD/CAM, the application of CAD/CAM fabricated tooth-coloured glass ceramic crowns, and the application of all-ceramic crowns and bridges using CAD/CAM fabricated zirconia based frameworks.

  18. 2-Cam LWIR imaging Stokes polarimeter

    Science.gov (United States)

    Kudenov, Michael W.; Dereniak, Eustace L.; Pezzaniti, Larry; Gerhart, Grant R.

    2008-04-01

    A 2-Cam micro-bolometer imaging polarimeter operating in the LWIR is presented. The system is capable of snapshot imaging Stokes polarimetry in any one channel (S I, S II, or S 3) by taking two simultaneous measurements of a scene. For measurements of S I or S II, the instrument relies on a specially optimized wire-grid beam-splitter. For measurements of S 3, a form birefringent quarter-wave retarder is inserted into the optical path. Specifics associated with the design of the wire-grid beam-splitter and the form birefringent quarter-wave retarder will be overviewed, with inclusion of RCWA simulations. Calibration and simulation procedures, as well as calibration targets, will be highlighted, and initial data from the instrument are presented.

  19. Comparative study of RetCamRetCam II vs. binocular ophthalmoscopy in a screening program for retinopathy of prematurity.

    Science.gov (United States)

    Tejada-Palacios, P; Zarratea, L; Moral, M; de la Cruz-Bértolo, J

    2015-08-01

    To determine the performance of RetCam vs. binocular ophthalmoscopy (BIO) in a screening program for retinopathy of prematurity (ROP). Observational comparative study with prospective data collection. Examinations with RetCam (n=169) were performed on 83 infants included in a screening program for ROP and stored for analysis at a later stage. An experienced ophthalmologist examined the ocular fundus with binocular indirect ophthalmoscopy (BIO). The RetCam images were assessed for the presence of ROP, zone, grade, and presence of plus disease. RetCam and BIO data were compared by visually to estimate sensitivity, specificity, positive (VPP) and negative (VPN) predictive values. ROP disease was detected in 108 eyes with BIO, and in 74 with RetCam. Out of 306 eyes examined with RetCam, false negative results were found in 34 eyes, with no false positives. Sensitivity of RetCam exam vs. BIO was 0.68, and specificity was 0.99. Positive predictive value was 0.93 and negative predictive value was 0.85. All 34 ROP cases not detected with RetCam were in zone III or outer zone II. They were all mild and regressed spontaneously. No threshold ROP was missed with RetCam. Binocular indirect ophthalmoscopy is the reference method for the diagnosis of ROP. RetCam may be used as an alternative for ROP screening. Copyright © 2010 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  20. Immediate CAD/ CAM Custom Fabricated Dental Implants

    Directory of Open Access Journals (Sweden)

    Jafar Kolahi

    2010-11-01

    Full Text Available Introduction: There will almost always be gaps between cylin-drical or screw shaped prefabricated implant surface and funnel-shaped tooth socket when an implant is placed immediately after tooth extraction. Hence expensive and difficult bone grafting is re-quired. A custom fabricated implant will be a pragmatic solution for this limitation.The hypothesis: First step following extraction of a tooth is data capture or scanning via a 3D scan method e.g. coordinate measuring machine or non-contact laser scanners such as triangulation range finder. Second step is reconstruction or modeling via editable CAD (computer-aided design model, allowing us to add retentive holes and correction of implant angle. Third step is fabrication via CAM (computer aided manufacturing followed by plasma cleaning process. Fourth step is insertion of the CAD/CAM custom fabricated one-stage implant in the fresh tooth socket. Optimal time for this step is 24-48 hours after extraction. The custom fabricated implant should not load 3-4 months. Usage of chlorhexidine mouth-rinse or chewing gum twice daily for 2 weeks and, in some cases oral antibiotic is recommended. Evaluation of the hypothesis: Contemporary dental implant system faced with several clinical and anatomical limitations such is low sinuses or nerve bundles. Complex and expensive surgical procedures such as nerve repositioning and sinus lift are frequently required. With custom fabricated implant we can overcome several of these limitations because insertion of custom fabricated implant will perform before alveolar bone recession.

  1. [Intraoperative augmented reality visualization. Current state of development and initial experiences with the CamC].

    Science.gov (United States)

    Weidert, S; Wang, L; von der Heide, A; Navab, N; Euler, E

    2012-03-01

    The intraoperative application of augmented reality (AR) has so far mainly taken place in the field of endoscopy. Here, the camera image of the endoscope was augmented by computer graphics derived mostly from preoperative imaging. Due to the complex setup and operation of the devices, they have not yet become part of routine clinical practice. The Camera Augmented Mobile C-arm (CamC) that extends a classic C-arm by a video camera and mirror construction is characterized by its uncomplicated handling. It combines its video live stream geometrically correct with the acquired X-ray. The clinical application of the device in 43 cases showed the strengths of the device in positioning for X-ray acquisition, incision placement, K-wire placement, and instrument guidance. With its new function and the easy integration into the OR workflow of any procedure that requires X-ray imaging, the CamC has the potential to become the first widely used AR technology for orthopedic and trauma surgery.

  2. Speed-sensing device aids crane operators

    Science.gov (United States)

    1964-01-01

    So that crane operators can judge payload movements accurately, a friction-driven multilobed cam device energizes a buzzer and indicator lamp in the crane cab. The signal frequency of this speed sensor has a sensitivity to hoist movement of 1/8 inch.

  3. EpCAM expression in normal, non-pathological tissues.

    Science.gov (United States)

    Schmelzer, Eva; Reid, Lola M

    2008-01-01

    Epithelial Cell Adhesion Molecule (EpCAM) is a transmembrane glycoprotein that is associated with various cancers. Most normal, non-pathological epithelial tissue is EpCAM positive with the exception of epidermal keratinocytes, gastric parietal cells, myoepithelial cells, thymic cortical epithelial, and hepatocytes. However, during early liver development EpCAM expression is also observed. In our studies, we have demonstrated that EpCAM is expressed in non-pathological human livers on hepatic progenitors in livers of all donor ages, from 16 weeks gestation fetal livers to adult. Hepatic progenitors of the liver consist of the stem cells and their descendants, the hepatoblasts, that give rise to the hepatocytic and biliary lineages. Both hepatic stem cells and most hepatoblasts express EpCAM, but only hepatoblasts are alpha-fetoprotein positive. The percentage of EpCAM positive progenitors in human livers varies with donor age and is about 2.5% in the adult and 12.1% in fetuses. In vivo, hepatic stem cells have been found associated with the canals of Hering. Xeno-transplantation experiments with EpCAM positive human liver cells have revealed their potential for proliferation and differentiation to mature liver parenchymal cells.

  4. Complementary and alternative medicine (CAM) among Australian hospital-based nurses: knowledge, attitude, personal and professional use, reasons for use, CAM referrals, and socio-demographic predictors of CAM users.

    Science.gov (United States)

    Shorofi, Seyed Afshin; Arbon, Paul

    2017-05-01

    This study was intended to examine CAM among Australian hospital-based nurses, identifying their knowledge, attitude, personal and professional use, reasons for use, CAM referrals, and socio-demographic predictors of CAM users. Nurses holding a qualification in nursing and working in surgical wards were included using a convenience sampling technique. A self-complete questionnaire was developed to achieve the aims of the study. Descriptive and non-parametric statistics were calculated to describe and analyse data. Overall, 95.7% and 49.7% of nurses reported personal and professional use of CAM, respectively. The most popular CAM/CAM domain personally and professionally used by nurses was massage therapy and mind-body therapies. The primary reason for personal use of CAM was "[it] fits into my way of life/philosophy". Furthermore, massage therapists were the most commonly recommended CAM practitioners to patients. Only 15.8% of nurses would always ask patients about use of herbal medicines as part of nursing history taking. Over one-fifth (22.4%) of nurses rated their attitude as having a very positive, and 60.3% rated themselves as having very little or no knowledge of CAM. A positive correlation was also found between knowledge and attitude about CAM. Positive attitude and higher knowledge about CAM were positively correlated to CAM referrals. Several socio-demographic factors predicted personal and professional use of CAM. This study revealed that nurses generally believe not to have sufficient knowledge of CAM but are open to use CAM with patients. Nurses' positive attitude toward and personal use of CAM could be an indication that they are poised for further integration of evidence-based CAM into nursing practice to treat whole person. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. IgCAMs redundantly control axon navigation in Caenorhabditis elegans

    Directory of Open Access Journals (Sweden)

    Voltmer-Irsch Susanne

    2009-04-01

    Full Text Available Abstract Background Cell adhesion molecules of the immunoglobulin superfamily (IgCAMs form one of the largest and most diverse families of adhesion molecules and receptors in the nervous system. Many members of this family mediate contact and communication among neurons during development. The Caenorhabditis elegans genome contains a comparatively small number of IgCAMs, most of which are evolutionarily conserved and found across all animal phyla. Only some of these have been functionally characterized so far. Results We systematically analyzed previously uncharacterized IgCAMs in C. elegans. Green fluorescent protein reporter constructs of 12 IgCAMs revealed that expression generally is not confined to a single tissue and that all tissues express at least one of the IgCAMs. Most IgCAMs were expressed in neurons. Within the nervous system significant overlap in expression was found in central components of the motor circuit, in particular the command interneurons, ventral cord motoneurons as well as motoneurons innervating head muscles. Sensory neurons are underrepresented among the cells expressing these IgCAMs. We isolated mutations for eight of the genes showing neuronal expression. Phenotypic analysis of single mutants revealed limited neuronal defects, in particular axon navigation defects in some of the mutants. Systematic genetic interaction studies uncovered two cases of functional overlap among three and four genes, respectively. A strain combining mutations in all eight genes is viable and shows no additional defects in the neurons that were analyzed, suggesting that genetic interactions among those genes are limited. Conclusion Genetic interactions involving multiple IgCAMs affecting axon outgrowth demonstrate functional overlap among IgCAMs during nervous system development.

  6. Optical CAM architecture for address lookup at 10 Gbps

    Science.gov (United States)

    Maniotis, P.; Terzenidis, N.; Pleros, N.

    2017-02-01

    Content Addressable Memories (CAMs) are widely used in nowadays router applications due to their fast bit searching capabilities. However, address loop-up operation cannot still keep up with high data-rate speeds of optical packet payload due to the limited speeds offered by electronic technology, which hardly can reach a few GHz. Despite this limitation, optics has still not managed to penetrate in the area of address look-up and forwarding operations due to the complete lack of optical CAM-based solutions. To the best of our knowledge, the first all-optical binary CAM cell has been only recently experimentally demonstrated by our group using an all-optical monolithically integrated InP Flip-Flop and an optical XOR gate, revealing error-free operation at 10 Gbps for both Content Addressing and Content Writing operations. In this paper, we extend our previous work by presenting for the first time to our knowledge an all-optical Ternary CAM cell architecture that allows also for a third matching state of "X" or "don't care", thus adding the necessary searching flexibility required by modern CAM-based solutions for supporting subnet-masked addresses. Moreover, we exploit the optical Ternary CAM cell towards deploying a complete CAM row formed by 4 Ternary CAM cells, demonstrating its operation through VPI simulations at 10 Gbps for an indicative 2 bit packet address and for both Content Addressing and Content Writing functionalities. The potential of this memory architecture to allow for up to 40 Gbps operation could presumably lead to fast CAM-based routing applications by enabling all-optical Address Lookup schemes.

  7. Turnkey CAD/CAM systems' integration with IPAD systems

    Science.gov (United States)

    Blauth, R. E.

    1980-01-01

    Today's commercially available turnkey CAD/CAM systems provide a highly interactive environment, and support many specialized application functions for the design/drafting/manufacturing process. This paper presents an overview of several aerospace companies which have successfully integrated turnkey CAD/CAM systems with their own company wide engineering and manufacturing systems. It also includes a vendor's view of the benefits as well as the disadvantages of such integration efforts. Specific emphasis is placed upon the selection of standards for representing geometric engineering data and for communicating such information between different CAD/CAM systems.

  8. Single unit CAD/CAM restorations: a literature review.

    Science.gov (United States)

    Freedman, Michael; Quinn, Frank; O'Sullivan, Michael

    2007-01-01

    Computer-aided design/computer-aided manufacture (CAD/CAM) has been used in dentistry since 1987. Since then, many CAD/CAM systems have been described, which enable the production of chair-side single unit dental restorations. These restorations are of comparable quality to those made by conventional techniques and have some specific advantages, including rapid production, improved wear properties, decreased laboratory fee and improved cross infection control. This literature review investigates the evidence base for the use of single unit CAD/CAM restorations. Materials, marginal gap, aesthetics, post-operative sensitivity, cementation, cost-effectiveness and longevity are discussed.

  9. Camønoen: Mobilizing pilgrim trails along collaborative platforms

    DEFF Research Database (Denmark)

    Gyimóthy, Szilvia; Widtfeld Meged, Jane

    2016-01-01

    and citizens alike? The recently opened pilgrim trail, Camønoen represents an adapted collaborative business model and as such an appropriate case to study new coastal value creation processes. Camønoen is a 175 km long newly designed walking trail across the islands of Møn, Nyord and Bogø. The trail...... is augmented by a digital platform on which hikers may directly connect with local citizens and book experiences ranging from private dinners to bird-watching and berry-picking. The platform Camønoen.org is hosted by the regional museum, which neither charges for intermediation, nor is responsible for vetting...

  10. Gender differences in autobiographical memory for everyday events: Retrieval elicited by SenseCam Images vs. Verbal Cues

    Science.gov (United States)

    St Jacques, Peggy L.; Conway, Martin A.; Cabeza, Roberto

    2011-01-01

    Gender differences are frequently observed in autobiographical memory (AM). Few studies, however, have investigated the neural basis of potential gender differences in AM. In the present functional MRI (fMRI) study we investigated gender differences in AMs elicited using dynamic visual images vs. verbal cues. We used a novel technology called a SenseCam, a wearable device that automatically takes thousands of photographs. SenseCam differs considerably from other prospective methods of generating retrieval cues because it does not disrupt the ongoing experience. This allowed us to control for potential gender differences in emotional processing and elaborative rehearsal, while manipulating how the AMs were elicited. We predicted that males would retrieve more richly experienced AMs elicited by the SenseCam images vs. the verbal cues, whereas females would show equal sensitivity to both cues. The behavioral results indicated that there were no gender differences in subjective ratings of reliving, importance, vividness, emotion and uniqueness, suggesting that gender differences in brain activity were not due to differences in these measures of phenomenological experience. Consistent with our predictions, the fMRI results revealed that males showed a greater difference in functional activity associated with the rich experience of SenseCam vs. Verbal Cues, than did females. PMID:20981611

  11. CAD/CAM approach to improving industry productivity gathers momentum

    Science.gov (United States)

    Fulton, R. E.

    1982-01-01

    Recent results and planning for the NASA/industry Integrated Programs for Aerospace-Vehicle Design (IPAD) program for improving productivity with CAD/CAM methods are outlined. The industrial group work is being mainly done by Boeing, and progress has been made in defining the designer work environment, developing requirements and a preliminary design for a future CAD/CAM system, and developing CAD/CAM technology. The work environment was defined by conducting a detailed study of a reference design process, and key software elements for a CAD/CAM system have been defined, specifically for interactive design or experiment control processes. Further work is proceeding on executive, data management, geometry and graphics, and general utility software, and dynamic aspects of the programs being developed are outlined

  12. Special Section: Complementary and Alternative Medicine (CAM): Time to Talk

    Science.gov (United States)

    ... with your health care providers any complementary and alternative medicines you take or are thinking about starting. Photo: ... and older use some form of complementary and alternative medicine (CAM). But less than one-third who use ...

  13. Surgical hip dislocation for treatment of cam femoroacetabular impingement

    Directory of Open Access Journals (Sweden)

    Milind M Chaudhary

    2015-01-01

    Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.

  14. Resin-composite blocks for dental CAD/CAM applications.

    Science.gov (United States)

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials.

  15. Finding the Evidence in CAM: a Student's Perspective

    Directory of Open Access Journals (Sweden)

    Jeffrey Ghassemi

    2005-01-01

    Full Text Available This commentary offers a future health care provider's perspective on the role of complementary and alternative medicine (CAM in Western (namely, in US medical education and practice. As a student of both public health and medicine in the United States, Jeffrey Ghassemi is interested in CAM's contribution to improving medical practice and teaching. The commentary highlights the ambiguous definitions of CAM to Westerners despite the rising popularity of and expenditures for alternative modalities of care. It then argues for collaboration between alternative and established medical communities to ascertain the scientific merits of CAM. It concludes by calling for a new medical paradigm that embraces the philosophies of both communities to advance education and patient care.

  16. Complementary and alternative (CAM) dietary therapies for cancer.

    Science.gov (United States)

    Weitzman, Sheila

    2008-02-01

    Complementary and alternative (CAM) therapies include a wide spectrum of dietary practices, some of which are claimed to cure cancer. Observational studies have shown consistently that predominantly plant-based diets reduce the risk for some adult type cancers such as breast cancer and prostate cancer. These studies form the basis of the American Cancer Society (ACS) nutritional guidelines. Many CAM diets prescribe a similar low fat, high fiber, high fruit and vegetable type diet, but also add detoxification and many different supplements to the basic diet which is then claimed to cure cancer. The potential advantages and disadvantages of CAM diets are discussed. Many aspects can be potentially harmful, particularly to the child with cancer. Advantages include involvement of the child and family in decision-making and care. There is no evidence to support the claims that CAM dietary therapies cure cancer.

  17. CAM Provider Use and Expenditures by Cancer Treatment Phase

    Science.gov (United States)

    Lafferty, William E.; Tyree, Patrick T.; Devlin, Sean M.; Andersen, M. Robyn; Diehr, Paula K.

    2008-01-01

    Objective To assess cancer patients’ utilization of complementary and alternative medical providers and the associated expenditures by specific treatment phases. Study Design Cross-sectional analysis of medical services utilization and expenditures during three therapeutic intervals: an initial treatment phase, continuing care, and end-of-life. Methods Analysis of an insurance claims database that had been matched to the Washington State SEER cancer registry. Results Of 2,900 registry-matched cancer patients 63.2% were female, the median age was 54 years, and 92.7% were white. Breast cancer was the most frequent diagnosis (52.7%), followed by prostate cancer (24.7%), lung cancer (10.1%), colon cancer (7.0%), and hematologic malignancies (5.6%). CAM provider using patients were 26.5% of the overall cohort (18.5% used chiropractors, 7.7% naturopathic physicians, 5.3% massage therapists, and 4.2% saw acupuncturists). The proportion of CAM using patients was similar during each treatment phase. All patients used some conventional care. Female gender, a breast cancer diagnosis, age, and white race were significant predictors of CAM use. Diagnosis of a musculoskeletal problem occurred at sometime during the study for 72.1% of cancer patients. CAM provider visits were 7.2% of total outpatient medical visits and 85.1% of CAM visits resulted in a musculoskeletal diagnosis. Expenditures for CAM providers were 0.3%, 1.0%, and 0.1% of all expenditures during the initial, continuing, and end-of-life phases respectively. Conclusion For cancer patients, musculoskeletal issues were the most commonly listed diagnosis made by a CAM provider. Although expenditures associated with CAM are a small proportion of the total, additional studies are necessary to determine the importance patients place on access to these services. PMID:18471036

  18. Availability Analysis of the Ventilation Stack CAM Interlock System

    CERN Document Server

    Young, J

    2000-01-01

    Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies, and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability.

  19. Aquatic CAM photosynthesis: a brief history of its discovery

    Science.gov (United States)

    Keeley, Jon E.

    2014-01-01

    Aquatic CAM (Crassulacean Acid Metabolism) photosynthesis was discovered while investigating an unrelated biochemical pathway concerned with anaerobic metabolism. George Bowes was a significant contributor to this project early in its infancy. Not only did he provide me with some valuable perspectives on peer review rejections, but by working with his gas exchange system I was able to take our initial observations of diel fluctuations in malic acid to the next level, showing this aquatic plant exhibited dark CO2 uptake. CAM is universal in all aquatic species of the worldwide Lycophyta genus Isoetes and non-existent in terrestrial Isoetes. Outside of this genus aquatic CAM has a limited occurrence in three other families, including the Crassulaceae. This discovery led to fascinating adventures in the highlands of the Peruvian Andes in search of Stylites, a terrestrial relative of Isoetes. Stylites is a plant that is hermetically sealed from the atmosphere and obtains all of its carbon from terrestrial sources and recycles carbon through CAM. Considering the Mesozoic origin of Isoetes in shallow pools, coupled with the fact that aquatic Isoetes universally possess CAM, suggests the earliest evolution of CAM photosynthesis was most likely not in terrestrial plants.

  20. The pineapple genome and the evolution of CAM photosynthesis.

    Science.gov (United States)

    Ming, Ray; VanBuren, Robert; Wai, Ching Man; Tang, Haibao; Schatz, Michael C; Bowers, John E; Lyons, Eric; Wang, Ming-Li; Chen, Jung; Biggers, Eric; Zhang, Jisen; Huang, Lixian; Zhang, Lingmao; Miao, Wenjing; Zhang, Jian; Ye, Zhangyao; Miao, Chenyong; Lin, Zhicong; Wang, Hao; Zhou, Hongye; Yim, Won C; Priest, Henry D; Zheng, Chunfang; Woodhouse, Margaret; Edger, Patrick P; Guyot, Romain; Guo, Hao-Bo; Guo, Hong; Zheng, Guangyong; Singh, Ratnesh; Sharma, Anupma; Min, Xiangjia; Zheng, Yun; Lee, Hayan; Gurtowski, James; Sedlazeck, Fritz J; Harkess, Alex; McKain, Michael R; Liao, Zhenyang; Fang, Jingping; Liu, Juan; Zhang, Xiaodan; Zhang, Qing; Hu, Weichang; Qin, Yuan; Wang, Kai; Chen, Li-Yu; Shirley, Neil; Lin, Yann-Rong; Liu, Li-Yu; Hernandez, Alvaro G; Wright, Chris L; Bulone, Vincent; Tuskan, Gerald A; Heath, Katy; Zee, Francis; Moore, Paul H; Sunkar, Ramanjulu; Leebens-Mack, James H; Mockler, Todd; Bennetzen, Jeffrey L; Freeling, Michael; Sankoff, David; Paterson, Andrew H; Zhu, Xinguang; Yang, Xiaohan; Smith, J Andrew C; Cushman, John C; Paull, Robert E; Yu, Qingyi

    2015-12-01

    Pineapple (Ananas comosus (L.) Merr.) is the most economically valuable crop possessing crassulacean acid metabolism (CAM), a photosynthetic carbon assimilation pathway with high water-use efficiency, and the second most important tropical fruit. We sequenced the genomes of pineapple varieties F153 and MD2 and a wild pineapple relative, Ananas bracteatus accession CB5. The pineapple genome has one fewer ancient whole-genome duplication event than sequenced grass genomes and a conserved karyotype with seven chromosomes from before the ρ duplication event. The pineapple lineage has transitioned from C3 photosynthesis to CAM, with CAM-related genes exhibiting a diel expression pattern in photosynthetic tissues. CAM pathway genes were enriched with cis-regulatory elements associated with the regulation of circadian clock genes, providing the first cis-regulatory link between CAM and circadian clock regulation. Pineapple CAM photosynthesis evolved by the reconfiguration of pathways in C3 plants, through the regulatory neofunctionalization of preexisting genes and not through the acquisition of neofunctionalized genes via whole-genome or tandem gene duplication.

  1. SmeltCam: underwater video codend for trawled nets with an application to the distribution of the imperiled delta smelt.

    Directory of Open Access Journals (Sweden)

    Frederick Feyrer

    Full Text Available Studying rare and sensitive species is a challenge in conservation biology. The problem is exemplified by the case of the imperiled delta smelt Hypomesus transpacificus, a small delicate fish species endemic to the San Francisco Estuary, California. Persistent record-low levels of abundance and relatively high sensitivity to handling stress pose considerable challenges to studying delta smelt in the wild. To attempt to overcome these and other challenges we have developed the SmeltCam, an underwater video camera codend for trawled nets. The SmeltCam functions as an open-ended codend that automatically collects information on the number and species of fishes that pass freely through a trawled net without handling. We applied the SmeltCam to study the fine-scale distribution of juvenile delta smelt in the water column in the upper San Francisco Estuary. We learned that during flood tides delta smelt were relatively abundant throughout the water column and that during ebb tides delta smelt were significantly less abundant and occurred only in the lower half and sides of the water column. The results suggest that delta smelt manipulate their position in the water column to facilitate retention in favorable habitats. With the application of the SmeltCam we increased the survival of individual delta smelt by 72% compared to using a traditional codend, where all of the fish would have likely died due to handling stress. The SmeltCam improves upon similar previously developed silhouette photography or video recording devices and demonstrates how new technology can be developed to address important questions in conservation biology as well as lessen the negative effects associated with traditional sampling methods on imperiled species.

  2. An impact device for forming wells in the earth

    Energy Technology Data Exchange (ETDEWEB)

    Turchaninov, Yu.N.; Dichenko, M.A.; Kovaleva, Ye.S.; Kutsak, A.B.

    1982-01-01

    The impact device for forming wells in the earth includes a body with an asymmetrical tip, a striker with elements for interacting with a shaft, an air distribution element, a shaft, made with threaded projections and connected with the body by means of a cam coupling, one of the half couplings of which is mounted on the shaft and the other, on the body of the device. In order to increase the operational reliability of the device, the end of the shaft is made with an even transfer from the threaded surface to a splined one, the form and dimensions of the transverse cross section of the projections of the surfaces of which are equal, where the elements for interacting the striker with the shaft are made in the form of removable pins, while the cam coupling is made with a constant linkage of the cams.

  3. Structural Design and Simulation of Passive Low Gravity Compensation for the Deployable Arm in the Device of Drilling and Collecting Lunar Soil

    OpenAIRE

    Tao Jianguo; Wang Guoxing; Li Jianyong

    2015-01-01

    As an important constituent part of the sampling device for lunar soil drilling, the deployable arm can help transfer the samples and avoid stretching. According to the ground experimental research requirements for deployable arm, this paper proposed a low-gravity compensation method of passive cam counter weight by establishing a Lagrangian dynamics model of deployable arm. It is emphasized on designing the profile curve of cam mechanism and the mechanical structure of cam component. By usin...

  4. The Subaru Hyper Suprime-Cam Survey

    Science.gov (United States)

    Strauss, Michael A.; Hyper Suprime-Cam Team

    2017-01-01

    High-latitude wide-field optical imaging surveys allow us to address scientific questions ranging from the properties of asteroids in the Solar System, to the structure of the Milky Way halo, to galaxy evolution, to the distribution of dark matter in the universe and the properties and evolution of dark energy. Hyper Suprime-Cam (HSC) is an imaging camera with a 1.77 deg2 field of view, mounted at the Prime Focus of the Subaru 8.2-m telescope operated by the National Astronomical Observatory of Japan on the summit of Maunakea in Hawaii. A consortium of astronomers from Japan, Taiwan and Princeton University is carrying out a three-layer, 300-night, multiband survey with this instrument. The Wide Layer will cover 1400 deg2 in five broad bands (grizy), to a 5 sigma point-source depth of r~26. The Deep Layer will cover 28 deg2 in four separate fields, going a magnitude deeper, and including narrow-band imaging to identify Lyman-alpha emitters at high redshift. The Ultradeep Layer will go a magnitude deeper still in two pointings (3.5 deg2), allowing studies of supernovae and other variable phenomenae.The survey started in 2014, and will continue through 2019. We have covered 240 deg2 of the Wide Layer in all five bands, and the median seeing in the i band is 0.60 arcseconds. In this introductory talk to the HSC special session, I will describe the quality of the data, plans for public data release, and touch upon some of the early science results, which range from the discovery of an ultrafaint dwarf galaxy in the Milky Way halo, to significant numbers of quasars and galaxies with redshifts between 5.7 and 7, to measurements of gravitational weak lensing around clusters.

  5. Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems.

    Science.gov (United States)

    Lee, Kyu-Bok; Park, Charn-Woon; Kim, Kyo-Han; Kwon, Tae-Yub

    2008-05-01

    This study evaluated the accuracy of marginal and internal fit between the all-ceramic crowns manufactured by a conventional double-layer computer-aided design/computer-aided manufacturing (CAD/CAM) system and a single-layer system. Ten standardized crowns were fabricated from each of these two systems: conventional double-layer CAD/CAM system (Procera) and a single-layer system (Cerec 3D). The copings and completed crowns were seated on the abutments by a special device that facilitated uniform loading, and the marginal discrepancies were measured. Internal gaps were also measured using a low-viscosity silicone material. Marginal discrepancies of Procera copings were significantly smaller than those of Procera crowns and Cerec 3D crowns (p 0.05). On internal gaps, Cerec 3D crowns showed significantly larger internal gaps than Procera copings and crowns (p system demonstrated acceptable marginal and internal fit.

  6. Multi-year application of WRF-CAM5 over East Asia-Part I: Comprehensive evaluation and formation regimes of O3 and PM2.5

    Energy Technology Data Exchange (ETDEWEB)

    He, Jian; Zhang, Yang; Wang, Kai; Chen, Ying; Leung, Lai-Yung; Fan, Jiwen; Li, Meng; Zheng, Bo; Zhang, Qiang; Duan, Fengkui; He, Kebin

    2017-06-09

    Accurate simulations of air quality and climate require robust model parameterizations on regional and global scales. The Weather Research and Forecasting model with Chemistry version 3.4.1 has been coupled with physics packages from the Community Atmosphere Model version 5 (CAM5) (WRF-CAM5) to assess the robustness of the CAM5 physics package for regional modeling at higher grid resolutions than typical grid resolutions used in global modeling. In this two-part study, Part I describes the application and evaluation of WRF-CAM5 over East Asia at a horizontal resolution of 36-km for six years: 2001, 2005, 2006, 2008, 2010, and 2011. The simulations are evaluated comprehensively with a variety of datasets from surface networks, satellites, and aircraft. The results show that meteorology is relatively well simulated by WRF-CAM5. However, cloud variables are largely or moderately underpredicted, indicating uncertainties in the model treatments of dynamics, thermodynamics, and microphysics of clouds/ices as well as aerosol-cloud interactions. For chemical predictions, the tropospheric column abundances of CO, NO2, and O3 are well simulated, but those of SO2 and HCHO are moderately overpredicted, and the column HCHO/NO2 indicator is underpredicted. Large biases exist in the surface concentrations of CO, NO2, and PM10 due to uncertainties in the emissions as well as vertical mixing. The underpredictions of NO lead to insufficient O3 titration, thus O3 overpredictions. The model can generally reproduce the observed O3 and PM indicators. These indicators suggest to control NOx emissions throughout the year, and VOCs emissions in summer in big cities and in winter over North China Plain, North/South Korea, and Japan to reduce surface O3, and to control SO2, NH3, and NOx throughout the year to reduce inorganic surface PM.

  7. Multi-year application of WRF-CAM5 over East Asia-Part I: Comprehensive evaluation and formation regimes of O3 and PM2.5

    Science.gov (United States)

    He, Jian; Zhang, Yang; Wang, Kai; Chen, Ying; Leung, L. Ruby; Fan, Jiwen; Li, Meng; Zheng, Bo; Zhang, Qiang; Duan, Fengkui; He, Kebin

    2017-09-01

    Accurate simulations of air quality and climate require robust model parameterizations on regional and global scales. The Weather Research and Forecasting model with Chemistry version 3.4.1 has been coupled with physics packages from the Community Atmosphere Model version 5 (CAM5) (WRF-CAM5) to assess the robustness of the CAM5 physics package for regional modeling at higher grid resolutions than typical grid resolutions used in global modeling. In this two-part study, Part I describes the application and evaluation of WRF-CAM5 over East Asia at a horizontal resolution of 36-km for six years: 2001, 2005, 2006, 2008, 2010, and 2011. The simulations are evaluated comprehensively with a variety of datasets from surface networks, satellites, and aircraft. The results show that meteorology is relatively well simulated by WRF-CAM5. However, cloud variables are largely or moderately underpredicted, indicating uncertainties in the model treatments of dynamics, thermodynamics, and microphysics of clouds/ices as well as aerosol-cloud interactions. For chemical predictions, the tropospheric column abundances of CO, NO2, and O3 are well simulated, but those of SO2 and HCHO are moderately overpredicted, and the column HCHO/NO2 indicator is underpredicted. Large biases exist in the surface concentrations of CO, NOx, and PM10 due to uncertainties in the emissions as well as vertical mixing. The underpredictions of NO lead to insufficient O3 titration, thus O3 overpredictions. The model can generally reproduce the observed O3 and PM indicators. These indicators suggest to control NOx emissions throughout the year, and VOCs emissions in summer in big cities and in winter over North China Plain, North/South Korea, and Japan to reduce surface O3, and to control SO2, NH3, and NOx throughout the year to reduce inorganic surface PM.

  8. Reliability, failure probability, and strength of resin-based materials for CAD/CAM restorations

    Directory of Open Access Journals (Sweden)

    Kiatlin Lim

    Full Text Available ABSTRACT Objective: This study investigated the Weibull parameters and 5% fracture probability of direct, indirect composites, and CAD/CAM composites. Material and Methods: Discshaped (12 mm diameter x 1 mm thick specimens were prepared for a direct composite [Z100 (ZO, 3M-ESPE], an indirect laboratory composite [Ceramage (CM, Shofu], and two CAD/CAM composites [Lava Ultimate (LU, 3M ESPE; Vita Enamic (VE, Vita Zahnfabrik] restorations (n=30 for each group. The specimens were polished, stored in distilled water for 24 hours at 37°C. Weibull parameters (m= modulus of Weibull, σ0= characteristic strength and flexural strength for 5% fracture probability (σ5% were determined using a piston-on-three-balls device at 1 MPa/s in distilled water. Statistical analysis for biaxial flexural strength analysis were performed either by both one-way ANOVA and Tukey's post hoc (α=0.05 or by Pearson's correlation test. Results: Ranking of m was: VE (19.5, LU (14.5, CM (11.7, and ZO (9.6. Ranking of σ0 (MPa was: LU (218.1, ZO (210.4, CM (209.0, and VE (126.5. σ5% (MPa was 177.9 for LU, 163.2 for CM, 154.7 for Z0, and 108.7 for VE. There was no significant difference in the m for ZO, CM, and LU. VE presented the highest m value and significantly higher than ZO. For σ0 and σ5%, ZO, CM, and LU were similar but higher than VE. Conclusion: The strength characteristics of CAD/ CAM composites vary according to their composition and microstructure. VE presented the lowest strength and highest Weibull modulus among the materials.

  9. Wear, strength, modulus and hardness of CAD/CAM restorative materials.

    Science.gov (United States)

    Lawson, Nathaniel C; Bansal, Ritika; Burgess, John O

    2016-11-01

    To measure the mechanical properties of several CAD/CAM materials, including lithium disilicate (e.max CAD), lithium silicate/zirconia (Celtra Duo), 3 resin composites (Cerasmart, Lava Ultimate, Paradigm MZ100), and a polymer infiltrated ceramic (Enamic). CAD/CAM blocks were sectioned into 2.5mm×2.5mm×16mm bars for flexural strength and elastic modulus testing and 4mm thick blocks for hardness and wear testing. E.max CAD and half the Celtra Duo specimens were treated in a furnace. Flexural strength specimens (n=10) were tested in a three-point bending fixture. Vickers microhardness (n=2, 5 readings per specimen) was measured with a 1kg load and 15s dwell time. The CAD/CAM materials as well as labial surfaces of human incisors were mounted in the UAB wear device. Cusps of human premolars were mounted as antagonists. Specimens were tested for 400,000 cycles at 20N force, 2mm sliding distance, 1Hz frequency, 24°C, and 33% glycerin lubrication. Volumetric wear and opposing enamel wear were measured with non-contact profilometry. Data were analyzed with 1-way ANOVA and Tukey post-hoc analysis (alpha=0.05). Specimens were observed with SEM. Properties were different for each material (pCAD and Celtra Duo were generally stronger, stiffer, and harder than the other materials. E.max CAD, Celtra Duo, Enamic, and enamel demonstrated signs of abrasive wear, whereas Cerasmart, Lava Ultimate, Paradigm MZ100 demonstrated signs of fatigue. Resin composite and resin infiltrated ceramic materials have demonstrated adequate wear resistance for load bearing restorations, however, they will require at least similar material thickness as lithium disilicate restorations due to their strength. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. Reliability, failure probability, and strength of resin-based materials for CAD/CAM restorations

    Science.gov (United States)

    Lim, Kiatlin; Yap, Adrian U-Jin; Agarwalla, Shruti Vidhawan; Tan, Keson Beng-Choon; Rosa, Vinicius

    2016-01-01

    ABSTRACT Objective: This study investigated the Weibull parameters and 5% fracture probability of direct, indirect composites, and CAD/CAM composites. Material and Methods: Discshaped (12 mm diameter x 1 mm thick) specimens were prepared for a direct composite [Z100 (ZO), 3M-ESPE], an indirect laboratory composite [Ceramage (CM), Shofu], and two CAD/CAM composites [Lava Ultimate (LU), 3M ESPE; Vita Enamic (VE), Vita Zahnfabrik] restorations (n=30 for each group). The specimens were polished, stored in distilled water for 24 hours at 37°C. Weibull parameters (m= modulus of Weibull, σ0= characteristic strength) and flexural strength for 5% fracture probability (σ5%) were determined using a piston-on-three-balls device at 1 MPa/s in distilled water. Statistical analysis for biaxial flexural strength analysis were performed either by both one-way ANOVA and Tukey's post hoc (α=0.05) or by Pearson's correlation test. Results: Ranking of m was: VE (19.5), LU (14.5), CM (11.7), and ZO (9.6). Ranking of σ0 (MPa) was: LU (218.1), ZO (210.4), CM (209.0), and VE (126.5). σ5% (MPa) was 177.9 for LU, 163.2 for CM, 154.7 for Z0, and 108.7 for VE. There was no significant difference in the m for ZO, CM, and LU. VE presented the highest m value and significantly higher than ZO. For σ0 and σ5%, ZO, CM, and LU were similar but higher than VE. Conclusion: The strength characteristics of CAD/ CAM composites vary according to their composition and microstructure. VE presented the lowest strength and highest Weibull modulus among the materials.

  11. PRODUCT DATA MANAGEMENT DALAM KAITAN DENGAN CAD/CAM

    Directory of Open Access Journals (Sweden)

    Bernardo Nugroho Yahya

    2004-01-01

    Full Text Available The future industry is the one who can manage the information system. Today, communication technology and distributed system computerization already have the ability to implement system that able to exchange and share information between different users. Product Data Management (PDM is an up-to-date and excellent method on managing the exchange and share of information. PDM is able to integrate and manage data analyzing process and documentation of the related product component physically. By adjusting the CAD/CAM on certain condition, the PDM will function maximally by using the information based on STEP (Standard for the Exchange of Product Data model. This article will explain the relationship between PDM system and CAD/CAM on industry. Abstract in Bahasa Indonesia : Sistem informasi merupakan ujung tombak sebuah perusahaan yang unggul di masa depan. Komputerisasi dengan sistem yang terdistribusi dan teknologi komunikasi saat ini memiliki kemampuan untuk mengimplementasikan sistem yang dapat menukar dan men-share informasi antar user yang berbeda. Teknologi yang mendapat cukup perhatian luas dalam hal pertukaran dan sharing informasi ini adalah Product Data Management (PDM. PDM dapat mengintegrasikan dan mengatur proses pengolahan data dan dokumen teknik yang berhubungan dengan komponen fisik produk yang bersangkutan. PDM akan berfungsi maksimal apabila kesesuaian dengan CAD/CAM diatur sedemikian rupa, dihubungkan dengan informasi berbasiskan STEP (Standard for the Exchange of Product Data model. Artikel ini akan menjelaskan hubungan antara sistem PDM dengan CAD/CAM dalam industri. Kata kunci: PDM, Manajemen Data, CAD/CAM, STEP.

  12. The Pleiotropic Role of L1CAM in Tumor Vasculature

    Science.gov (United States)

    Angiolini, Francesca; Cavallaro, Ugo

    2017-01-01

    Angiogenesis, the formation of new vessels, is a key step in the development, invasion, and dissemination of solid tumors and, therefore, represents a viable target in the context of antitumor therapy. Indeed, antiangiogenic approaches have given promising results in preclinical models and entered the clinical practice. However, in patients, the results obtained so far with antiangiogenic drugs have not completely fulfilled expectations, especially because their effect has been transient with tumors developing resistance and evasion mechanisms. A better understanding of the mechanisms that underlie tumor vascularization and the functional regulation of cancer vessels is a prerequisite for the development of novel and alternative antiangiogenic treatments. The L1 cell adhesion molecule (L1CAM), a cell surface glycoprotein previously implicated in the development and plasticity of the nervous system, is aberrantly expressed in the vasculature of various cancer types. L1CAM plays multiple pro-angiogenic roles in the endothelial cells of tumor-associated vessels, thus emerging as a potential therapeutic target. In addition, L1CAM prevents the maturation of cancer vasculature and its inhibition promotes vessel normalization, a process that is thought to improve the therapeutic response of tumors to cytotoxic drugs. We here provide an overview on tumor angiogenesis and antiangiogenic therapies and summarize the current knowledge on the biological role of L1CAM in cancer vasculature. Finally, we highlight the clinical implications of targeting L1CAM as a novel antiangiogenic and vessel-normalizing approach. PMID:28134764

  13. CamBAfx: Workflow Design, Implementation and Application for Neuroimaging.

    Science.gov (United States)

    Ooi, Cinly; Bullmore, Edward T; Wink, Alle-Meije; Sendur, Levent; Barnes, Anna; Achard, Sophie; Aspden, John; Abbott, Sanja; Yue, Shigang; Kitzbichler, Manfred; Meunier, David; Maxim, Voichita; Salvador, Raymond; Henty, Julian; Tait, Roger; Subramaniam, Naresh; Suckling, John

    2009-01-01

    CamBAfx is a workflow application designed for both researchers who use workflows to process data (consumers) and those who design them (designers). It provides a front-end (user interface) optimized for data processing designed in a way familiar to consumers. The back-end uses a pipeline model to represent workflows since this is a common and useful metaphor used by designers and is easy to manipulate compared to other representations like programming scripts. As an Eclipse Rich Client Platform application, CamBAfx's pipelines and functions can be bundled with the software or downloaded post-installation. The user interface contains all the workflow facilities expected by consumers. Using the Eclipse Extension Mechanism designers are encouraged to customize CamBAfx for their own pipelines. CamBAfx wraps a workflow facility around neuroinformatics software without modification. CamBAfx's design, licensing and Eclipse Branding Mechanism allow it to be used as the user interface for other software, facilitating exchange of innovative computational tools between originating labs.

  14. CamBAfx: workflow design, implementation and application for neuroimaging

    Directory of Open Access Journals (Sweden)

    Cinly Ooi

    2009-08-01

    Full Text Available CamBAfx is a workflow application designed for both researchers who use workflows to process data (consumers and those who design them (designers. It provides a front-end (user interface optimized for data processing designed in a way familiar to consumers. The back-end uses a pipeline model to represent workflows since this is a common and useful metaphor used by designers and is easy to manipulate compared to other representations like programming scripts. As an Eclipse Rich Client Platform application, CamBAfx's pipelines and functions can be bundled with the software or downloaded post-installation. The user interface contains all the workflow facilities expected by consumers. Using the Eclipse Extension Mechanism designers are encouraged to customize CamBAfx for their own pipelines. CamBAfx wraps a workflow facility around neuroinformatics software without modification. CamBAfx's design, licensing and Eclipse Branding Mechanism allow it to be used as the user interface for other software, facilitating exchange of innovative computational tools between originating labs.

  15. On the nature of facultative and constitutive CAM: environmental and developmental control of CAM expression during early growth of Clusia, Kalanchöe, and Opuntia.

    Science.gov (United States)

    Winter, Klaus; Garcia, Milton; Holtum, Joseph A M

    2008-01-01

    The capacity to induce crassulacean acid metabolism developmentally (constitutive CAM) and to up-regulate CAM expression in response to drought stress (facultative CAM) was studied in whole shoots of seven species by measuring net CO(2) gas exchange for up to 120 day-night cycles during early growth. In Clusia rosea, CAM was largely induced developmentally. Well-watered seedlings began their life cycle as C(3) plants and developed net dark CO(2) fixation indicative of CAM after the initiation of the fourth leaf pair following the cotyledons. Thereafter, CAM activity increased progressively and drought stress led to only small additional, reversible increases in dark CO(2) fixation. In contrast, CAM expression was overwhelmingly under environmental control in seedlings and mature plants of Clusia pratensis. C(3)-type CO(2) exchange was maintained under well-watered conditions, but upon drought stress, CO(2) exchange shifted, in a fully reversible manner, to a CAM-type pattern. Clusia minor showed CO(2) exchange reponses intermediate to those of C. rosea and C. pratensis. Clusia cretosa operated in the C(3) mode at all times. Notably, reversible stress-induced increases of dark CO(2) fixation were also observed during the developmental progression to pronounced CAM in young Kalanchoë daigremontiana and Kalanchoë pinnata, two species considered constitutive CAM species. Drought-induced up-regulation of CAM was even detected in young cladodes of a cactus, Opuntia ficus-indica, an archetypal constitutive CAM species. Evidently, the defining characteristics of constitutive and facultative CAM are shared, to variable degrees, by all CAM species.

  16. Principle and curve of planetary indexing cam mechanisms

    Institute of Scientific and Technical Information of China (English)

    LIU Ming-tao; ZHANG Ce; YANG Yu-hu

    2006-01-01

    A new type of planetary indexing cam mechanism called type IV is presented.The transmission principle of type IV is discussed.Based on the principle of formarion of conjugate tooth contour,the equations of the cam's pitch curve are derived.The continuity and symmetry of the cain's pitch curve are also analyzed.It can be concluded that:1) This type has no output institution so the output precision can be improved;2) The asymmetrical two-ring structure is used to-overcome dead point and its phase angle is equal to (π-2π/n) ;3) The continuous condition of the cam's pitch curve is that the average transmission ratio is -n in an intermittent motion period.

  17. Xi-CAM v1.2.3

    Energy Technology Data Exchange (ETDEWEB)

    2016-09-06

    Xi-CAM aims to provide a community driven platform for multimodal analysis in synchrotron science. The platform core provides a robust plugin infrastructure for extensibility, allowing continuing development to simply add further functionality. Current modules include tools for characterization with (GI)SAXS, Tomography, and XAS. This will continue to serve as a development base as algorithms for multimodal analysis develop. Seamless remote data access, visualization and analysis are key elements of Xi-CAM, and will become critical to synchrotron data infrastructure as expectations for future data volume and acquisition rates rise with continuously increasing throughputs. The highly interactive design elements of Xi-cam will similarly support a generation of users which depend on immediate data quality feedback during high-throughput or burst acquisition modes.

  18. MegaPipe: the MegaCam image stacking pipeline

    CERN Document Server

    Gwyn, Stephen D J

    2009-01-01

    This paper describes the MegaPipe image processing pipeline at the Canadian Astronomical Data Centre (CADC). The pipeline takes multiple images from the MegaCam mosaic camera on CFHT and combines them into a single output image. MegaPipe takes as input detrended MegaCam images and does a careful astrometric and photometric calibration on them. The calibrated images are then resampled and combined into image stacks. MegaPipe is run on PI data by request, data from large surveys (the CFHT Legacy Survey and the Next Generation Virgo Survey) and all non-proprietary MegaCam data in the CFHT archive. The stacked images and catalogs derived from these images are available through the CADC website. Currently, 1500 square degrees have been processed.

  19. GravityCam: Higher Resolution Visible Wide-Field Imaging

    CERN Document Server

    Mackay, Craig; Steele, Iain

    2016-01-01

    The limits to the angular resolution achievable with conventional ground-based telescopes are unchanged over 70 years. Atmospheric turbulence limits image quality to typically ~1 arcsec in practice. We have developed a new concept of ground-based imaging instrument called GravityCam capable of delivering significantly sharper images from the ground than is normally possible without adaptive optics. The acquisition of visible images at high speed without significant noise penalty has been made possible by advances in optical and near IR imaging technologies. Images are recorded at high speed and then aligned before combination and can yield a 3-5 fold improvement in image resolution. Very wide survey fields are possible with widefield telescope optics. We describe GravityCam and detail its application to accelerate greatly the rate of detection of Earth size planets by gravitational microlensing. GravityCam will also improve substantially the quality of weak shear studies of dark matter distribution in distant...

  20. Passivity of conventional and CAD/CAM fabricated implant frameworks.

    Science.gov (United States)

    de Araújo, Gabriela Monteiro; de França, Danilo Gonzaga Bernardo; Silva Neto, João Paulo; Barbosa, Gustavo Augusto Seabra

    2015-01-01

    The objective of this research was to evaluate the passivity by measuring the passive fit and strain development of frameworks screwed on abutments, made by CAD/CAM technology, and to compare these parts with samples manufactured by conventional casting. Using CAD/CAM technology, four samples were made from zirconia (Zircad) and four samples were manufactured from cobalt-chrome (CoCrcad). The control groups were four specimens of cobalt-chrome, made by one-piece casting (CoCrci), with a total of 12 frameworks. To evaluate the passive fit, the vertical misfit at the abutment-framework interface was measured with scanning electron microscopy (250×) when only one screw was tightened. The mean strain in these frameworks was analyzed by photoelasticity test. A significant difference in the passive fit was observed between the control and sample groups. CoCrcad exhibited the best value of passive fit (48.76±13.45 µm) and CoCrci the worst (187.55±103.63 µm); Zircad presented an intermediate value (103.81±43.15 µm). When compared to the other groups, CoCrci showed the highest average stress around the implants (17.19±7.22 kPa). It was concluded that CAD/CAM-fabricated frameworks exhibited better passivity compared with conventionally fabricated frameworks. CAD/CAM-fabricated Co-Cr frameworks may exhibit better passive fit compared with CAD/CAM-fabricated zirconia frameworks. Even so, similar levels of stress were achieved for CAD/CAM-fabricated frameworks.

  1. The application of CAD / CAM technology in Dentistry

    Science.gov (United States)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  2. Fault Diagnosis of a High-Speed Cam-Driven Pin Assembly System

    Directory of Open Access Journals (Sweden)

    Chi-Cheng Cheng

    2016-01-01

    Full Text Available A cam-driven mechanical system applied for pin assembly of connectors of electrical devices is studied in this paper. Three cooperative cams are involved in the tasks of approaching, cutting, insertion, and restoring. In order to meet the demanded productivity growth, the operation speed tends to be elevated. However, high running speeds usually cause deficiencies of pin dropping and inaccurate positioning. Diagnosis is therefore conducted to explore their physical reasons so that modification of future mechanical design can be made. Frequency responses of experimental measurements show greater natural frequency and system stiffness caused by nonlinear dynamics for higher operation speed. It also appears that the clamping force is reduced and drift of the locked pin’s location is induced for higher running speed. In addition, separation of the fixture system induced by contact oscillation generates clearance larger than the thickness of the pin. Based on the mathematical models obtained from the technique of system identification, deeper insight of the mechanical system and future system improvement can be highly expected.

  3. Luting of CAD/CAM ceramic inlays: direct composite versus dual-cure luting cement.

    Science.gov (United States)

    Kameyama, Atsushi; Bonroy, Kim; Elsen, Caroline; Lührs, Anne-Katrin; Suyama, Yuji; Peumans, Marleen; Van Meerbeek, Bart; De Munck, Jan

    2015-01-01

    The aim of this study was to investigate bonding effectiveness in direct restorations. A two-step self-etch adhesive and a light-cure resin composite was compared with luting with a conventional dual-cure resin cement and a two-step etch and rinse adhesive. Class-I box-type cavities were prepared. Identical ceramic inlays were designed and fabricated with a computer-aided design/computer-aided manufacturing (CAD/CAM) device. The inlays were seated with Clearfil SE Bond/Clearfil AP-X (Kuraray Medical) or ExciTE F DSC/Variolink II (Ivoclar Vivadent), each by two operators (five teeth per group). The inlays were stored in water for one week at 37°C, whereafter micro-tensile bond strength testing was conducted. The micro-tensile bond strength of the direct composite was significantly higher than that from conventional luting, and was independent of the operator (P<0.0001). Pre-testing failures were only observed with the conventional method. High-power light-curing of a direct composite may be a viable alternative to luting lithium disilicate glass-ceramic CAD/CAM restorations.

  4. CAD/CAM generated all-ceramic primary telescopic prostheses.

    Science.gov (United States)

    Kurbad, A; Ganz, S; Kurbad, S

    2012-01-01

    Computer-aided design and manufacturing (CAD/CAM) systems have proven effective not only for the manufacture of crown and bridge frameworks, inlays, onlays and veneers, but also for the generation of all-ceramic primary telescopic prostheses in more than 10 years of use in dental technology. The new InLab 4.0 software generation makes it possible to design and mill primary telescopic prostheses with CAD/CAM technology. The computer-generated raw crowns for these restorations require very little manual adaptation. The secondary crowns are manufactured by electroforming and bonded onto the tertiary structure or framework.

  5. Impact of IPAD on CAD/CAM database university research

    Science.gov (United States)

    Leach, L. M.; Wozny, M. J.

    1984-01-01

    IPAD program has provided direction, focus and software products which impacted on CAD/CAM data base research and follow-on research. The relationship of IPAD to the research projects which involve the storage of geometric data in common data ase facilities such as data base machines, the exchange of data between heterogeneous data bases, the development of IGES processors, the migration of lrge CAD/CAM data base management systems to noncompatible hosts, and the value of RIM as a research tool is described.

  6. FlashCam: A fully digital camera for CTA telescopes

    CERN Document Server

    Pühlhofer, G; Biland, A; Florin, D; Föhr, C; Gadola, A; Hermann, G; Kalkuhl, C; Kasperek, J; Kihm, T; Koziol, J; Manalaysay, A; Marszalek, A; Rajda, P J; Schanz, T; Steiner, S; Straumann, U; Tenzer, C; Vogler, P; Vollhardt, A; Weitzel, Q; Winiarski, K; Zietara, K

    2012-01-01

    The future Cherenkov Telescope Array (CTA) will consist of several tens of telescopes of different mirror sizes. CTA will provide next generation sensitivity to very high energy photons from few tens of GeV to >100 TeV. Several focal plane instrumentation options are currently being evaluated inside the CTA consortium. In this paper, the current status of the FlashCam prototyping project is described. FlashCam is based on a fully digital camera readout concept and features a clean separation between photon detector plane and signal digitization/triggering electronics.

  7. The use of CAD/CAM in dentistry.

    Science.gov (United States)

    Davidowitz, Gary; Kotick, Philip G

    2011-07-01

    Computer-aided design (CAD) and computer-aided manufacturing (CAM) have become an increasingly popular part of dentistry over the past 25 years. The technology, which is used in both the dental laboratory and the dental office, can be applied to inlays, onlays, veneers, crowns, fixed partial dentures, implant abutments, and even full-mouth reconstruction. This article discusses the history of CAD/CAM in dentistry and gives an overview of how it works. It also provides information on the advantages and disadvantages, describes the main products available, discusses how to incorporate the new technology into your practice, and addresses future applications. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. CAD/CAM in the Brazilian aeronautical industry

    Science.gov (United States)

    Lampi, L. H.; Embraer, S. A.

    Features, applications and progress in the usage of CAD/CAM since 1980 by an aircraft manufacturer in Brazil are described. The system comprises 34 graphics work stations dedicated to structural design, lofting, electrical cable routing, finite element modeling and quality control. Standardized work methods have been devised to enhance productivity. Programs have been defined for finite element stress analysis and generating wiring diagrams. The computerized design capabilities have increased productivity for hole boring accuracy through work on digitized controllers. Psychological testing has been initiated to identify users who can adapt more easily to CAD/CAM utilization.

  9. FATIGUE DEVICE FOR TESTING ANKLE JOINT ENDOPROSTHESES

    Directory of Open Access Journals (Sweden)

    Cristian TOADER-PASTI

    2012-05-01

    Full Text Available The paper proposes a model of a fatigue device for testing dedicated to ankle prostheses. The concept of the testing device relies on two aspects: almost any type of ankle prosthesis can be tested on it and it has to work on INSTRON axial-torsion testing machine. Starting from these requirements, a 3D functional assembly that reproduces the real movement of the ankle joint during gait cycle has been designed. The device is based on a cam-follower mechanism.

  10. CAM visual stimulation with conventional method of occlusion treatment in amblyopia: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Ali Reza Jafari

    2014-04-01

    Conclusion: Using of CAM visual stimulation along with conventional occlusion will further improve visual acuity and stereopsis in amblyopic children. These findings recommended the CAM visual stimulation as an accompanying and complementary method in amblyopia treatment.

  11. Special Section: Complementary and Alternative Medicine (CAM):Quiz on Complementary and Alternative Medicine

    Science.gov (United States)

    ... Issues Special Section CAM Quiz on Complementary and Alternative Medicine Past Issues / Winter 2009 Table of Contents For ... for low back pain. True False Complementary and alternative medicine (CAM) includes: Meditation Chiropractic Use of natural products, ...

  12. Mitochondrial respiration in ME-CAM, PEPCK-CAM, and C₃ succulents: comparative operation of the cytochrome, alternative, and rotenone-resistant pathways.

    Science.gov (United States)

    Peckmann, Klaus; von Willert, Dieter J; Martin, Craig E; Herppich, Werner B

    2012-05-01

    Mitochondria are important in the function and control of Crassulacean acid metabolism (CAM) during organic acid accumulation at night and acid decarboxylation in the day. In plants of the malic enzyme-(ME) type and the phosphoenolpyruvate carboxykinase- (PEPCK) type, mitochondria may exert their role in the control of the diurnal rhythm of malic and citric acids to a differential degree. In plants of both CAM types, the oxidative capacity of mitochondria, as well as the activity of CAM-linked mitochondrial enzymes, and of the alternative and the rotenone-resistant pathways of substrate oxidation were compared. Furthermore, a C₃ succulent was included, as well as both C₃ and CAM forms of Mesembryanthemum crystallinum during a salt-induced C₃-to-CAM shift. Mitochondria of PEPCK-type CAM plants exhibited a lower activity of malate oxidation, ratio of malate to succinate oxidation, and activity of mitochondrial NAD-ME. With the exception of Kalanchoë daigremontiana, leaf mitochondria of all other CAM species were highly sensitive to cyanide (80-100%), irrespective of the oxidant used. This indicates that the alternative oxidase is not of general importance in CAM. By contrast, rotenone-insensitive substrate oxidation was very high (50-90%) in all CAM species. This is the first comparison of the rotenone-insensitive pathway of respiration in plants with different CAM-types. The results of this study confirm that mitochondria are involved in the control of CAM to different degrees in the two CAM types, and they highlight the multiple roles of mitochondria in CAM.

  13. EpCAM and the biology of hepatic stem/progenitor cells

    Science.gov (United States)

    Theise, Neil D.; Schmelzer, Eva; Boulter, Luke; Gires, Olivier; van Grunsven, Leo A.

    2014-01-01

    Epithelial cell adhesion molecule (EpCAM) is a transmembrane glycoprotein, which is frequently and highly expressed on carcinomas, tumor-initiating cells, selected tissue progenitors, and embryonic and adult stem cells. During liver development, EpCAM demonstrates a dynamic expression, since it can be detected in fetal liver, including cells of the parenchyma, whereas mature hepatocytes are devoid of EpCAM. Liver regeneration is associated with a population of EpCAM-positive cells within ductular reactions, which gradually lose the expression of EpCAM along with maturation into hepatocytes. EpCAM can be switched on and off through a wide panel of strategies to fine-tune EpCAM-dependent functional and differentiative traits. EpCAM-associated functions relate to cell–cell adhesion, proliferation, maintenance of a pluripotent state, regulation of differentiation, migration, and invasion. These functions can be conferred by the full-length protein and/or EpCAM-derived fragments, which are generated upon regulated intramembrane proteolysis. Control by EpCAM therefore not only depends on the presence of full-length EpCAM at cellular membranes but also on varying rates of the formation of EpCAM-derived fragments that have their own regulatory properties and on changes in the association of EpCAM with interaction partners. Thus spatiotemporal localization of EpCAM in immature liver progenitors, transit-amplifying cells, and mature liver cells will decisively impact the regulation of EpCAM functions and might be one of the triggers that contributes to the adaptive processes in stem/progenitor cell lineages. This review will summarize EpCAM-related molecular events and how they relate to hepatobiliary differentiation and regeneration. PMID:25477371

  14. Effects of Complementary and Alternative Medicines (CAM) on the Metabolism and Transport of Anticancer Drugs

    OpenAIRE

    Mooiman, K.D.

    2013-01-01

    The use of complementary and alternative medicines (CAM), such as herbs and dietary supplements, has become more popular among cancer patients. Cancer patients use these supplements for different reasons such as reduction of side effects and improvement of their quality of life. In general, the use of CAM is considered as safe. However, concomitant use of CAM and anticancer drugs could result in serious safety issues since CAM have the potential to cause pharmacokinetic interactions with conv...

  15. Evaluation of complementary-alternative medicine (CAM) questionnaire development for Indonesian clinical psychologists: A pilot study.

    Science.gov (United States)

    Liem, Andrian; Newcombe, Peter A; Pohlman, Annie

    2017-08-01

    This study aimed to evaluate questionnaire development to measure the knowledge of Complementary-Alternative Medicine (CAM), attitudes towards CAM, CAM experiences, and CAM educational needs of clinical psychologists in Indonesia. A 26-item questionnaire was developed through an extensive literature search. Data was obtained from provisional psychologists from the Master of Professional Clinical Psychology programs at two established public universities in urban areas of Indonesia. To validate the questionnaire, panel reviews by executive members of the Indonesian Clinical Psychology Association (ICPA), experts in health psychology, and experts in public health and CAM provided their professional judgements. The self-reporting questionnaire consisted of four scales including: knowledge of CAM (6 items), attitudes towards CAM (10 items), CAM experiences (4 items), and CAM educational needs (6 items). All scales, except CAM Experiences, were assessed on a 7-point Likert scale. Sixty provisional psychologists were eligible to complete the questionnaire with a response rate of 73% (N=44). The results showed that the CAM questionnaire was reliable (Cronbach's coefficient alpha range=0.62-0.96; item-total correlation range=0.14-0.92) and demonstrated content validity. Following further psychometric evaluation, the CAM questionnaire may provide the evidence-based information to inform the education and practice of Indonesian clinical psychologists. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Footage: Action Cam Shorts as Cartographic Captures of Time.

    NARCIS (Netherlands)

    Verhoeff, N.

    2015-01-01

    This short article reflects on short videos of action cam footage that are widely disseminated on online platforms. These first-person perspective shorts are compared to early cinema’s phantom rides in the use of point-of-view shots, and a dizzying effect of heightened mobility and versatility in ca

  17. Mechanical properties and DIC analyses of CAD/CAM materials

    Science.gov (United States)

    Roperto, Renato; Akkus, Anna; Akkus, Ozan; Porto-Neto, Sizenando; Teich, Sorin; Lang, Lisa; Campos, Edson

    2016-01-01

    Background This study compared two well-known computer-aided-design/computer-aided-manufactured (CAD/CAM) blocks (Paradigm MZ100 [3M ESPE] and Vitablocs Mark II [Vita] in terms of fracture toughness (Kic), index of brittleness (BI) and stress/strain distributions. Material and Methods Three-point bending test was used to calculate the fracture toughness, and the relationship between the Kic and the Vickers hardness was used to calculate the index of brittleness. Additionally, digital image correlation (DIC) was used to analyze the stress/strain distribution on both materials. Results The values for fracture toughness obtained under three-point bending were 1.87Pa√m (±0.69) for Paradigm MZ100 and 1.18Pa√m (±0.17) for Vitablocs Mark II. For the index of brittleness, the values for Paradigm and Vitablocs were 73.13μm-1/2 (±30.72) and 550.22μm-1/2 (±82.46). One-way ANOVA was performed to find differences (α=0.05) and detected deviation between the stress/strain distributions on both materials. Conclusions Both CAD/CAM materials tested presented similar fracture toughness, but, different strain/stress distributions. Both materials may perform similarly when used in CAD/CAM restorations. Key words:Ceramic, CAD/CAM, hybrid materials, composite resin, fracture toughness. PMID:27957262

  18. Schools (Students) Exchanging CAD/CAM Files over the Internet.

    Science.gov (United States)

    Mahoney, Gary S.; Smallwood, James E.

    This document discusses how students and schools can benefit from exchanging computer-aided design/computer-aided manufacturing (CAD/CAM) files over the Internet, explains how files are exchanged, and examines the problem of selected hardware/software incompatibility. Key terms associated with information search services are defined, and several…

  19. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability.

  20. Including CAD/CAM dentistry in a dental school curriculum.

    Science.gov (United States)

    Browning, William D; Reifeis, Paul; Willis, Lisa; Kirkup, Michele L

    2013-01-01

    Shaping a clinical curriculum that is appropriate for novice dentists, is based on high-quality evidence of efficacy, yet reflects current practices is challenging. CAD/CAM units have been available to dentists since the late '80s. Recent improvements in the software, hardware and the clinical performance of available all-ceramic blocks have keyed a surge in interest. Based on a careful review of the systems available and, equally importantly, a review of the research regarding the longevity of reinforced glass ceramics, IUSD decided to add training on the use of the E4D CAD/CAM system to the curriculum. Students now receive lectures, preclinical hands-on training and clinical experience in fabricating all-ceramic restorations. At present any student who is interested in providing an all-ceramic restoration for his/her patient can do so using our CAD/CAM system. In a little less than one year our undergraduate dental students have provided 125 all-ceramic crowns to their patients. Clinical faculty have been impressed with the marginal fit and esthetics of the crowns. Finally, with students designing, milling, sintering and staining the restorations the CAD/CAM systems has reduced lab costs significantly.

  1. Footage: Action Cam Shorts as Cartographic Captures of Time.

    NARCIS (Netherlands)

    Verhoeff, N.

    2015-01-01

    This short article reflects on short videos of action cam footage that are widely disseminated on online platforms. These first-person perspective shorts are compared to early cinema’s phantom rides in the use of point-of-view shots, and a dizzying effect of heightened mobility and versatility in

  2. Doing Performance Appraisal the Right Way: The CAM Process.

    Science.gov (United States)

    Ramsgard, William C.

    1994-01-01

    Explains the CAM (Clarity, Awareness, Merit Recognition) process for performance reviews in which supervisors declare personal values, expectations, and operational methods; select employee skills for enhancement and define results; provide feedback, recognition and reinforcement; and distribute merit rewards and build deeper mutual commitments to…

  3. The pineapple genome and the evolution of CAM photosynthesis

    Science.gov (United States)

    Pineapple (Ananas comosus (L.) Merr.) is the most economically valuable crop possessing crassulacean acid metabolism (CAM), a photosynthetic carbon assimilation pathway with high water-use efficiency, and the second most important tropical fruit. We sequenced the genomes of pineapple varieties F153 ...

  4. SenseCam: A new tool for memory rehabilitation?

    Science.gov (United States)

    Dubourg, L; Silva, A R; Fitamen, C; Moulin, C J A; Souchay, C

    2016-12-01

    The emergence of life-logging technologies has led neuropsychologist to focus on understanding how this new technology could help patients with memory disorders. Despite the growing number of studies using life-logging technologies, a theoretical framework supporting its effectiveness is lacking. This review focuses on the use of life-logging in the context of memory rehabilitation, particularly the use of SenseCam, a wearable camera allowing passive image capture. In our opinion, reviewing SenseCam images can be effective for memory rehabilitation only if it provides more than an assessment of prior occurrence in ways that reinstates previous thoughts, feelings and sensory information, thus stimulating recollection. Considering the fact that, in memory impairment, self-initiated processes are impaired, we propose that the environmental support hypothesis can explain the value of SenseCam for memory retrieval. Twenty-five research studies were selected for this review and despite the general acceptance of the value of SenseCam as a memory technique, only a small number of studies focused on recollection. We discuss the usability of this tool to improve episodic memory and in particular, recollection. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Synthesis and analysis of coupler curves with combined planar cam ...

    African Journals Online (AJOL)

    user

    works are done on the synthesis of coupler curves or path generation using four bar mechanism. The present work ..... Sadler, J.P., and Yang, Z. 1990. Optimal design of cam-linkage mechanisms for dynamic-force characteristics. Journal of.

  6. Abnormal placental development and early embryonic lethality in EpCAM-null mice.

    Directory of Open Access Journals (Sweden)

    Keisuke Nagao

    Full Text Available BACKGROUND: EpCAM (CD326 is encoded by the tacstd1 gene and expressed by a variety of normal and malignant epithelial cells and some leukocytes. Results of previous in vitro experiments suggested that EpCAM is an intercellular adhesion molecule. EpCAM has been extensively studied as a potential tumor marker and immunotherapy target, and more recent studies suggest that EpCAM expression may be characteristic of cancer stem cells. METHODOLOGY/PRINCIPAL FINDINGS: To gain insights into EpCAM function in vivo, we generated EpCAM -/- mice utilizing an embryonic stem cell line with a tacstd1 allele that had been disrupted. Gene trapping resulted in a protein comprised of the N-terminus of EpCAM encoded by 2 exons of the tacstd1 gene fused in frame to betageo. EpCAM +/- mice were viable and fertile and exhibited no obvious abnormalities. Examination of EpCAM +/- embryos revealed that betageo was expressed in several epithelial structures including developing ears (otocysts, eyes, branchial arches, gut, apical ectodermal ridges, lungs, pancreas, hair follicles and others. All EpCAM -/- mice died in utero by E12.5, and were small, developmentally delayed, and displayed prominent placental abnormalities. In developing placentas, EpCAM was expressed throughout the labyrinthine layer and by spongiotrophoblasts as well. Placentas of EpCAM -/- embryos were compact, with thin labyrinthine layers lacking prominent vascularity. Parietal trophoblast giant cells were also dramatically reduced in EpCAM -/- placentas. CONCLUSION: EpCAM was required for differentiation or survival of parietal trophoblast giant cells, normal development of the placental labyrinth and establishment of a competent maternal-fetal circulation. The findings in EpCAM-reporter mice suggest involvement of this molecule in development of vital organs including the gut, kidneys, pancreas, lungs, eyes, and limbs.

  7. Drug price regulation under consumer moral hazard. Two-part tariffs, uniform price or third-degree price discrimination?

    Science.gov (United States)

    Felder, Stefan

    2004-12-01

    Drug price differences across national markets as they exist in the EU are often justified by the concept of Ramsey prices: with fixed costs for R&D, the optimal mark-ups on marginal costs are inversely related to the price elasticity in the individual markets. This well-known result prevails if consumer moral hazard is taken into account. Contrary to the situation without moral hazard, the uniform price does not necessarily dominate discriminatory pricing in welfare terms. The two-part tariff is a better alternative as it allows governments to address moral hazard. A uniform price combined with lump-payments reflecting differences in the willingness to pay and the moral hazard in member states appears to be an attractive option for a common EU drug market.

  8. The Unsuspecting CAM User: Cancer patients and the changing nature of holistic health

    Directory of Open Access Journals (Sweden)

    A M. Kabel

    2014-05-01

    Full Text Available The number of cancer patients using complementary and alternative medicine (CAM in the United States is growing, yet little is known about the meaning these activities have for users. Current literature supports the assumption that stigma surrounding CAM and holistic health practices are responsible for the reluctance of many cancer patients to self-identify as CAM users. This study explored the frequency of use, and familiarity with CAM among 25 female patients at a Midwestern oncology clinic. Findings suggest that patients need to be asked about CAM use multiple times and in multiple formats to gain an accurate assessment. Also, the assumptions about stigma may no longer be the reason patients are less than forthcoming about CAM use. The rise of integrative medicine and shifting boundaries of the holistic health movement may be equally, or in some cases, more responsible for the reluctance for CAM users to self-identify.

  9. Perspectives of complementary and alternative medicine (CAM) practitioners in the support and treatment of infertility.

    Science.gov (United States)

    O'Reilly, Erin; Sevigny, Marika; Sabarre, Kelley-Anne; Phillips, Karen P

    2014-10-14

    Infertility patients are increasingly using complementary and alternative medicine (CAM) to supplement or replace conventional fertility treatments. The objective of this study was to determine the roles of CAM practitioners in the support and treatment of infertility. Ten semi-structured interviews were conducted in Ottawa, Canada in 2011 with CAM practitioners who specialized in naturopathy, acupuncture, traditional Chinese medicine, hypnotherapy and integrated medicine. CAM practitioners played an active role in both treatment and support of infertility, using a holistic, interdisciplinary and individualized approach. CAM practitioners recognized biological but also environmental and psychosomatic determinants of infertility. Participants were receptive to working with physicians, however little collaboration was described. Integrated infertility patient care through both collaboration with CAM practitioners and incorporation of CAM's holistic, individualized and interdisciplinary approaches would greatly benefit infertility patients.

  10. CAD/CAM machining Vs pre-sintering in-lab fabrication techniques of Y-TZP ceramic specimens: Effects on their mechanical fatigue behavior.

    Science.gov (United States)

    Zucuni, C P; Guilardi, L F; Fraga, S; May, L G; Pereira, G K R; Valandro, L F

    2017-03-18

    This study evaluated the effects of different pre-sintering fabrication processing techniques of Y-TZP ceramic (CAD/CAM Vs. in-lab), considering surface characteristics and mechanical performance outcomes. Pre-sintered discs of Y-TZP ceramic (IPS e.max ZirCAD, Ivoclar Vivadent) were produced using different pre-sintering fabrication processing techniques: Machined- milling with a CAD/CAM system; Polished- fabrication using a cutting device followed by polishing (600 and 1200 SiC papers); Xfine- fabrication using a cutting machine followed by grinding with extra-fine diamond bur (grit size 30 μm); Fine- fabrication using a cutting machine followed by grinding with fine diamond bur (grit size 46 μm); SiC- fabrication using a cutting machine followed by grinding with 220 SiC paper. Afterwards, the discs were sintered and submitted to roughness (n=35), surface topography (n=2), phase transformation (n=2), biaxial flexural strength (n=20), and biaxial flexural fatigue strength (fatigue limit) (n=15) analyses. No monoclinic-phase content was observed in all processing techniques. It can be observed that obtaining a surface with similar characteristics to CAD/CAM milling is essential for the observation of similar mechanical performance. On this sense, grinding with fine diamond bur before sintering (Fine group) was the best mimic protocol in comparison to the CAD/CAM milling.

  11. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    Science.gov (United States)

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p CAD/CAM systems are more precise than the CAM-only system for the manufacture of four-unit FDPs.

  12. The faulty statistics of complementary alternative medicine (CAM).

    Science.gov (United States)

    Pandolfi, Maurizio; Carreras, Giulia

    2014-09-01

    The authors illustrate the difficulties involved in obtaining a valid statistical significance in clinical studies especially when the prior probability of the hypothesis under scrutiny is low. Since the prior probability of a research hypothesis is directly related to its scientific plausibility, the commonly used frequentist statistics, which does not take into account this probability, is particularly unsuitable for studies exploring matters in various degree disconnected from science such as complementary alternative medicine (CAM) interventions. Any statistical significance obtained in this field should be considered with great caution and may be better applied to more plausible hypotheses (like placebo effect) than that examined - which usually is the specific efficacy of the intervention. Since achieving meaningful statistical significance is an essential step in the validation of medical interventions, CAM practices, producing only outcomes inherently resistant to statistical validation, appear not to belong to modern evidence-based medicine.

  13. Illness narratives in cancer: CAM and spiritual practices

    DEFF Research Database (Denmark)

    Ulrich, Anita; Evron, Lotte; Ostenfeld-Rosenthal, Ann

    2011-01-01

    Objectives: In this paper,we investigate Danish cancer patients’ narratives on spiritual beliefs and practices and the relationship these practices may have to complementary and alternative medicine (CAM). Design: Narrative inquiry is used to uncover how spiritual beliefs and practices may......, religious and spiritual issues were not extensively unfolded in participants’ illness narratives. However, these issues were significantly elaborated on in narratives by four female participants. Conclusion: We propose that for some cancer patients CAM may function, not only or primarily as a treatment...... for cancer related symptoms and side effects, but as a spiritual practice as well. For some individuals this may be true to an even higher extent than in established religious institutions....

  14. CAM Modalities Can Stimulate Advances in Theoretical Biology

    Directory of Open Access Journals (Sweden)

    Alex Hankey

    2005-01-01

    Full Text Available Most complementary medicine is distinguished by not being supported by underlying theory accepted by Western science. However, for those who accept their validity, complementary and alternative medicine (CAM modalities offer clues to understanding physiology and medicine more deeply. Ayurveda and vibrational medicine are stimulating new approaches to biological regulation. The new biophysics can be integrated to yield a single consistent theory, which may well underly much of CAM—a true ‘physics of physick’. The resulting theory seems to be a new, fundamental theory of health and etiology. It suggests that many CAM approaches to health care are scientifically in advance of those based on current Western biology. Such theories may well constitute the next steps in our scientific understanding of biology itself. If successfully developed, these ideas could result in a major paradigm shift in both biology and medicine, which will benefit all interested parties—consumers, health professionals, scientists, institutions and governments.

  15. Tufting enteropathy with EpCAM mutation: case report

    Directory of Open Access Journals (Sweden)

    Karla Lais Pêgas

    2014-06-01

    Full Text Available Tufting enteropathy (TE, also known as intestinal epithelial dysplasia (IED, is a rare congenital enteropathy related to an earlyonset of severe intractable diarrhea due to specific abnormalities of the intestinal epithelium and mutations of the EpCAM gene. TE is characterized by clinical and histological heterogeneity, such as with low or without mononuclear cell infiltration of the lamina propria, and abnormalities of basement membrane. TE can be associated with malformations, other epithelial diseases, or to abnormal enterocytes development and/or differentiation. The authors report a case of a Brazilian child with TE associated with c.556-14A>G mutation in the EpCAM gene (NM_002354.2.

  16. Integrated CAD/CAM: Problems, prognosis, and role of IPAD

    Science.gov (United States)

    Nilson, E. N.

    1980-01-01

    Major technology problems impede the development and evolution of totally integrated interactive CAD/CAM systems. IPAD is playing an important role in the identification of these problems and is contributing significantly to their solution. It is the purpose of this presentation to examine some of these issues, look at the prognosis of obtaining effective solutions, and point up some of the past and expected contributions of IPAD to this technology.

  17. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm(3)) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Lucrécio, Camões e os deuses

    Directory of Open Access Journals (Sweden)

    Milton Torres

    2009-12-01

    Full Text Available Este artigo trata do uso que Lucrécio e Camões fizeram dos deuses da mitologia clássica, por razões pertinentes às convenções da poesia épica e a despeito de sua descrença na existência dos mesmos, sugerindo que ambos constróem os deuses para depois desconstruí-los de forma cabal e definitiva.

  19. Product Recommendation System Based on Personal Preference Model Using CAM

    Science.gov (United States)

    Murakami, Tomoko; Yoshioka, Nobukazu; Orihara, Ryohei; Furukawa, Koichi

    Product recommendation system is realized by applying business rules acquired by data maining techniques. Business rules such as demographical patterns of purchase, are able to cover the groups of users that have a tendency to purchase products, but it is difficult to recommend products adaptive to various personal preferences only by utilizing them. In addition to that, it is very costly to gather the large volume of high quality survey data, which is necessary for good recommendation based on personal preference model. A method collecting kansei information automatically without questionnaire survey is required. The constructing personal preference model from less favor data is also necessary, since it is costly for the user to input favor data. In this paper, we propose product recommendation system based on kansei information extracted by text mining and user's preference model constructed by Category-guided Adaptive Modeling, CAM for short. CAM is a feature construction method that can generate new features constructing the space where same labeled examples are close and different labeled examples are far away from some labeled examples. It is possible to construct personal preference model by CAM despite less information of likes and dislikes categories. In the system, retrieval agent gathers the products' specification and user agent manages preference model, user's likes and dislikes. Kansei information of the products is gained by applying text mining technique to the reputation documents about the products on the web site. We carry out some experimental studies to make sure that prefrence model obtained by our method performs effectively.

  20. Comparison Between GAMIL, and CAM2 on Interannual Variability Simulation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Recently, a new atmospheric general circulation model (GAMIL: Grid-point Atmospheric Model of IAP LASG) has been developed at the Institute of Atmospheric Physics (IAP), Chinese Academy of Sciences (CAS), which is based on the Community Atmospheric Model Version 2 (CAM2) of the National Center for Atmospheric Research (NCAR). Since the two models have the same physical processes but different dynamical cores, the interannual variability simulation performances of the two models are compared. The ensemble approach is used to reduce model internal variability.In general, the simulation performances of the two models are similar. Both models have good performance in simulating total space-time variability and the Southern Oscillation Index. GAMIL performs better in the Eastern Asian winter circulation simulation than CAM2, and the model internal variability of GAMIL has a better response to external forcing than that of CAM2. These indicate that the improvement of the dynamic core is very important. It is also verified that there is less predictability in the middle and high latitudes than in the low latitudes.

  1. Optical spectroscopy of RU Cam, a pulsating carbon star

    CERN Document Server

    Kipper, Tonu

    2007-01-01

    We analysed the high resolution spectra of a RU Cam, classified as W Vir type star. The atmospheric parameters of RU Cam were estimated Teff=5250K and log g=1.0. The hydrogen deficiency of RU Cam was not confirmed. The iron abundance, [Fe/H]=-0.37, is close to the solar one. Abundances of most other elements are also close to normal. We found considerable excesses of carbon and nitrogen: [C/Fe]=+0.98, [N/Fe]=+0.60. The carbon to oxygen ratio is C/O$\\ge$1. The carbon isotopic abundance ratio is equal to C^12/C^13=4.5. For sodium a moderate overabundance Na/Fe=+0.55 was obtained. For two moments of observations we found close heliocentric velocity values, Vr=-21.7+/-0.8 and -23.1+/-1.0 km/s. Both spectra contain a peculiar feature - an emission component of NaI doublet which location agrees with the radial velocity from the bulk of metallic lines. For our two observing moments we found no dependence of radial velocities on the formation depth or on excitation energy for metallic lines.

  2. ChemCam analysis of Martian fine dust

    Science.gov (United States)

    Lasue, Jeremie; Mangold, Nicolas; Cousin, Agnes; Meslin, Pierre-Yves; Wiens, Roger; Gasnault, Olivier; Rapin, William; Schroder, Susanne; Ollila, Ann; Fabre, Cécile; Berger, Gilles; Le Mouélic, Stéphane; Dehouck, Erwin; Forni, Olivier; Maurice, Sylvestre; Anderson, Ryan; Bridges, Nathan; Clark, Benton; Clegg, Samuel; d'Uston, Claude; Goetz, Walter; Johnson, Jeffrey R.; Lanza, Nina; Madsen, Morten; Melikechi, Noureddine; Newsom, Horton; Sautter, Violaine; Martin-Torres, Javier; Zorzano, Maria-Paz; MSL Science Team

    2016-10-01

    In this work, we examine the chemical composition of dust observed by the Chemistry Camera (ChemCam) instrument onboard the Mars Science Laboratory (MSL) rover at Gale Crater. The Laser Induced Breakdown Spectroscopy technique analyses samples without preparation, which allows detection of the elemental composition of surface deposits. Mars aeolian fine dust (soils encountered at Gale crater. The composition is also similar to the soils and fine dust measured by APXS for the elements common to both instruments. The minor elements quantified by ChemCam (Ba, Sr, Rb, Li, Mn, Cr) are within the range of soil surveys, but we see a higher concentration of Li than in other types of remotely characterized targets. Sulfur is possibly detected at the ChemCam limit of detection. Hydrogen is clearly identified, indicating that this fine dust is a contributor to the H content of the martian soils, as also detected by the SAM and CheMin instruments, and provides constraints as to which fraction of the Martian surface is hydrated and altered. In conclusion, the finest fraction of dust particles on the surface of Mars contains hydrated components mixed intimately within the fine aeolian dust fraction, suggesting that this dust likely originates from mechanical weathering of altered grains.

  3. Gas exchange and leaf anatomy of a C3-CAM hybrid, Yucca gloriosa (Asparagaceae).

    Science.gov (United States)

    Heyduk, Karolina; Burrell, Nia; Lalani, Falak; Leebens-Mack, Jim

    2016-03-01

    While the majority of plants use the typical C3 carbon metabolic pathway, ~6% of angiosperms have adapted to carbon limitation as a result of water stress by employing a modified form of photosynthesis known as Crassulacean acid metabolism (CAM). CAM plants concentrate carbon in the cells by temporally separating atmospheric carbon acquisition from fixation into carbohydrates. CAM has been studied for decades, but the evolutionary progression from C3 to CAM remains obscure. In order to better understand the morphological and physiological characteristics associated with CAM photosynthesis, phenotypic variation was assessed in Yucca aloifolia, a CAM species, Yucca filamentosa, a C3 species, and Yucca gloriosa, a hybrid species derived from these two yuccas exhibiting intermediate C3-CAM characteristics. Gas exchange, titratable leaf acidity, and leaf anatomical traits of all three species were assayed in a common garden under well-watered and drought-stressed conditions. Yucca gloriosa showed intermediate phenotypes for nearly all traits measured, including the ability to acquire carbon at night. Using the variation found among individuals of all three species, correlations between traits were assessed to better understand how leaf anatomy and CAM physiology are related. Yucca gloriosa may be constrained by a number of traits which prevent it from using CAM to as high a degree as Y. aloifolia. The intermediate nature of Y. gloriosa makes it a promising system in which to study the evolution of CAM. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  4. Evaluating rare amino acid substitutions (RGC_CAMs in a yeast model clade.

    Directory of Open Access Journals (Sweden)

    Kenneth Polzin

    Full Text Available When inferring phylogenetic relationships, not all sites in a sequence alignment are equally informative. One recently proposed approach that takes advantage of this inequality relies on sites that contain amino acids whose replacement requires multiple substitutions. Identifying these so-called RGC_CAM substitutions (after Rare Genomic Changes as Conserved Amino acids-Multiple substitutions requires that, first, at any given site in the amino acid sequence alignment, there must be a minimum of two different amino acids; second, each amino acid must be present in at least two taxa; and third, the amino acids must require a minimum of two nucleotide substitutions to replace each other. Although theory suggests that RGC_CAM substitutions are expected to be rare and less likely to be homoplastic, the informativeness of RGC_CAM substitutions has not been extensively evaluated in biological data sets. We investigated the quality of RGC_CAM substitutions by examining their degree of homoplasy and internode certainty in nearly 2.7 million aligned amino acid sites from 5,261 proteins from five species belonging to the yeast Saccharomyces sensu stricto clade whose phylogeny is well-established. We identified 2,647 sites containing RGC_CAM substitutions, a number that contrasts sharply with the 100,887 sites containing RGC_non-CAM substitutions (i.e., changes between amino acids that require only a single nucleotide substitution. We found that RGC_CAM substitutions had significantly lower homoplasy than RGC_non-CAM ones; specifically RGC_CAM substitutions showed a per-site average homoplasy index of 0.100, whereas RGC_non-CAM substitutions had a homoplasy index of 0.215. Internode certainty values were also higher for sites containing RGC_CAM substitutions than for RGC_non-CAM ones. These results suggest that RGC_CAM substitutions possess a strong phylogenetic signal and are useful markers for phylogenetic inference despite their rarity.

  5. EpCAM modulates NF-κB signaling and interleukin-8 expression in breast cancer.

    Science.gov (United States)

    Sankpal, Narendra V; Fleming, Timothy P; Gillanders, William E

    2013-04-01

    The epithelial cell adhesion molecule (EpCAM) is a 40-kD type I transmembrane protein that is overexpressed in human epithelial cancers and is currently the target of molecular therapy based on its overexpression at the cell surface. Recently, we and others have shown a role for EpCAM in cell signaling and carcinogenesis, and EpCAM expression seems to promote breast cancer invasion. Interleukin-8 (IL-8/CXCL-8) is an inflammatory cytokine that has recently been shown to modulate breast cancer invasion and angiogenesis. In preliminary experiments, we identified a correlation between EpCAM and IL-8 expression in primary human breast cancers. Specific ablation of EpCAM in breast cancer cell lines results in decreased IL-8 expression, and IL-8 contributes to EpCAM-dependent breast cancer invasion. Specific ablation of EpCAM is also associated with decreased NF-κB transcription factor activity, decreased phosphorylation of the NF-κB family member RELA, and increased IκBα protein expression. EpCAM modulates IL-8 expression at baseline, and following IL-1β stimulation, which is known to be a potent inducer of NF-κB in breast cancer. In functional rescue experiments, specific ablation of RELA or forced expression of the NF-κB inhibitor protein IκBα prevented EpCAM-dependent rescue of IL-8 promoter activity. These studies show for the first time that EpCAM can modulate NF-κB transcription factor activity and IL-8 expression in breast cancer and confirm the role of EpCAM signaling in modulating breast cancer invasion. Further study is required to define the molecular mechanism(s) of EpCAM signaling in breast cancer and to direct the rational development of molecular therapies targeting EpCAM.

  6. Reverse Revenue Sharing Contract versus Two-Part Tariff Contract under a Closed-Loop Supply Chain System

    Directory of Open Access Journals (Sweden)

    Zunya Shi

    2016-01-01

    Full Text Available The importance of remanufacturing has been recognized in research and practice. The integrated system, combining the forward and reverse activities of supply chains, is called closed-loop supply chain (CLSC system. By coordination in the CLSC system, players will get economic improvement. This paper studies different coordination performances of two types of contracts, two-part tariff (TTC and reverse revenue sharing contract (RRSC, in a closed-loop system. Through mathematical analysis based on Stackelberg Game Theory, we find that it is easy for manufacturer to improve more profits and retailer’s collection effects by adjusting the ratio of transfer collection price through RRSC, and we also give the function to calculate the best ratio of transfer collection price, which may be a valuable reference for the decision maker in practice. Besides, our results also suggest that although the profits of the coordinated CLSC system are always higher than the contradictory scenario, the RRSC is more favorable to the manufacturer than to the retailer, as results show that the manufacturer will share more profits from the system through RRSC. Therefore, RRSC has attracted the manufacturers more to closing the supply chain for economic consideration.

  7. A Bayesian two part model applied to analyze risk factors of adult mortality with application to data from Namibia.

    Directory of Open Access Journals (Sweden)

    Lawrence N Kazembe

    Full Text Available Despite remarkable gains in life expectancy and declining mortality in the 21st century, in many places mostly in developing countries, adult mortality has increased in part due to HIV/AIDS or continued abject poverty levels. Moreover many factors including behavioural, socio-economic and demographic variables work simultaneously to impact on risk of mortality. Understanding risk factors of adult mortality is crucial towards designing appropriate public health interventions. In this paper we proposed a structured additive two-part random effects regression model for adult mortality data. Our proposal assumed two processes: (i whether death occurred in the household (prevalence part, and (ii number of reported deaths, if death did occur (severity part. The proposed model specification therefore consisted of two generalized linear mixed models (GLMM with correlated random effects that permitted structured and unstructured spatial components at regional level. Specifically, the first part assumed a GLMM with a logistic link and the second part explored a count model following either a Poisson or negative binomial distribution. The model was used to analyse adult mortality data of 25,793 individuals from the 2006/2007 Namibian DHS data. Inference is based on the Bayesian framework with appropriate priors discussed.

  8. Pattern and predictors of complementary and alternative medicine (CAM) use among pediatric patients with epilepsy.

    Science.gov (United States)

    Doering, Jan H; Reuner, Gitta; Kadish, Navah E; Pietz, Joachim; Schubert-Bast, Susanne

    2013-10-01

    Parents of pediatric patients with chronic conditions such as epilepsy increasingly opt for complementary and alternative medicine (CAM). However, data on the pattern and reasons of CAM use in childhood epilepsy are scarce. The objectives of this study were as follows: first, to characterize CAM use among pediatric patients with epilepsy by assessing its spectrum, prevalence, costs, and frequency of use; second, to evaluate the influence of CAM use on compliance and satisfaction with conventional care as well as to explore parent-child neurologist communication concerning CAM; and third, to investigate predictors of CAM use. A postal survey was administered to all parents of pediatric outpatients with epilepsy aged 6 to 12, who have received treatment at the neuropediatric outpatient clinic of the University Children's Hospital Heidelberg between 2007 and 2009. One hundred thirty-two of the 297 distributed questionnaires were suitable for inclusion in statistical analysis (44.7%). Forty-nine participants indicated that their children used CAM during the previous year (37.1%). Thirty different types of CAM were used, with homeopathy (55.1%), osteopathy (24.5%), and kinesiology (16.3%) being the most commonly named. A mean of 86€ (0€-500€) and 3h (1 h-30 h) per month was committed to CAM treatment. Only 53% of the users informed their child neurologist of the additional CAM treatment, while 85.6% of all parents wished to discuss CAM options with their child neurologist. Seventy-five percent of users considered the CAM treatment effective. Among the participants most likely to seek CAM treatment are parents whose children show a long duration of epileptic symptoms, parents who make use of CAM treatment themselves, and parents who value a holistic and natural treatment approach. A substantial portion of pediatric patients with epilepsy receive CAM treatment. The high prevalence of use and significant level of financial and time resources spent on CAM indicate the

  9. Complementary and alternative medicine (CAM) in obstetrics and gynaecology: a survey of office-based obstetricians and gynaecologists regarding attitudes towards CAM, its provision and cooperation with other CAM providers in the state of Hesse, Germany.

    Science.gov (United States)

    Münstedt, K; Maisch, M; Tinneberg, H R; Hübner, J

    2014-12-01

    Whereas we have some information on complementary medicine in the field of oncology, little is known about complementary medicine in the field of obstetrics and gynaecology especially outside of hospitals. All office-based obstetricians and gynaecologists in the state of Hesse, Germany, were contacted and asked to fill in an assessment form regarding cooperation in the field of complementary and alternative medicine (CAM), as well as the perceived efficacy of various CAM methods for a number of pathological conditions in the field of obstetrics and gynaecology. It was found that more than half of Hessian office-based obstetricians and gynaecologists had existing cooperation regarding CAM, especially with colleagues, but also midwives, pharmacists, physiotherapists, and health practitioners. The probability of cooperation was significantly inversely associated with age. It was found that the probability for advising CAM differed between various health problems. The following CAM methods were considered reasonable for the treatment of different conditions: phytotherapy for climacteric complaints and premenstrual syndrome; homoeopathy for puerperal problems; acupuncture and traditional Chinese medicine for complaints during pregnancy; and dietary supplements for the side effects of cancer therapy. The analysis shows that there is much cooperation in the field of CAM. Comparison between physicians' perceived efficacy of CAM methods and objective findings shows that there is a need for the provision of valid information in the field.

  10. A new method for generating ceramic restorations: a CAD-CAM system.

    Science.gov (United States)

    Leinfelder, K F; Isenberg, B P; Essig, M E

    1989-06-01

    The CAD-CAM CEREC system is a small, complex unit developed for electronically designing and milling ceramic restorations. The system makes it possible to generate a restoration without taking impressions, developing temporary prostheses, and without laboratory assistance. The entire restorative procedure is performed in one appointment. Basic features include the following: the cavity preparation is scanned stereo-photogrammetrically, using a three-dimensional miniature video camera; the small microprocessor unit stores the three-dimensional pattern depicted on the screen; the video display serves as a format for the necessary manual construction via an electrical signal; the microprocessor develops the final three-dimensional restoration from the two-dimensional construction; the processing unit automatically deletes data beyond the margins of the preparation; the electronic information is transferred numerically to the miniature three-axis milling device; driven by a water turbine unit, the milling device generates a precision-fitting restoration from a standard ceramic block; the entire process of electronic designing and subsequent milling of a ceramic restoration requires approximately 10 to 15 minutes.

  11. A Variable-Speed Approach for Preventing Cam-Follower Separation

    Science.gov (United States)

    Yan, Hong-Sen; Tsai, Wu-Jung

    The follower separation is a major impediment to the operating speed increase of force-closed cam mechanisms. This problem traditionally is solved by increasing the spring preload or spring rate to enlarge the return force. An alternative approach with variable cam speed is proposed to prevent follower separation and thereby to raise the average operating speed. By properly designing the cam speed to change the follower motion, the critical motion characteristics leading to follower separation can be avoided. The cam speed trajectory is expressed using the Bezier function. A mathematical model is developed for analyzing the cycle time and the critical times of follower separation. Then a design model for optimizing the critical average cam speed without follower separation is developed to specify the design parameters of this trajectory. Two design examples with different cam motion programs are given for demonstrating the feasibility of this approach.

  12. Delirium, sedation and analgesia in the intensive care unit: a multinational, two-part survey among intensivists.

    Directory of Open Access Journals (Sweden)

    Alawi Luetz

    Full Text Available Analgesia, sedation and delirium management are important parts of intensive care treatment as they are relevant for patients' clinical and functional long-term outcome. Previous surveys showed that despite this fact implementation rates are still low. The primary aim of the prospective, observational multicenter study was to investigate the implementation rate of delirium monitoring among intensivists. Secondly, current practice concerning analgesia and sedation monitoring as well as treatment strategies for patients with delirium were assesed. In addition, this study compares perceived and actual practice regarding delirium, sedation and analgesia management. Data were obtained with a two-part, anonymous survey, containing general data from intensive care units in a first part and data referring to individual patients in a second part. Questionnaires from 101 hospitals (part 1 and 868 patients (part 2 were included in data analysis. Fifty-six percent of the intensive care units reported to monitor for delirium in clinical routine. Fourty-four percent reported the use of a validated delirium score. In this respect, the survey suggests an increasing use of delirium assessment tools compared to previous surveys. Nevertheless, part two of the survey revealed that in actual practice 73% of included patients were not monitored with a validated score. Furthermore, we observed a trend towards moderate or deep sedation which is contradicting to guideline-recommendations. Every fifth patient was suffering from pain. The implementation rate of adequate pain-assessment tools for mechanically ventilated and sedated patients was low (30%. In conclusion, further efforts are necessary to implement guideline recommendations into clinical practice. The study was registered (ClinicalTrials.gov identifier: NCT01278524 and approved by the ethical committee.

  13. The U. S. transportation sector in the year 2030: results of a two-part Delphi survey.

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, G.; Stephens, T.S. (Energy Systems); (Univ. of California at Davis); (ES)

    2011-10-11

    A two-part Delphi Survey was given to transportation experts attending the Asilomar Conference on Transportation and Energy in August, 2011. The survey asked respondents about trends in the US transportation sector in 2030. Topics included: alternative vehicles, high speed rail construction, rail freight transportation, average vehicle miles traveled, truck versus passenger car shares, vehicle fuel economy, and biofuels in different modes. The survey consisted of two rounds -- both asked the same set of seven questions. In the first round, respondents were given a short introductory paragraph about the topic and asked to use their own judgment in their responses. In the second round, the respondents were asked the same questions, but were also given results from the first round as guidance. The survey was sponsored by Argonne National Lab (ANL), the National Renewable Energy Lab (NREL), and implemented by University of California at Davis, Institute of Transportation Studies. The survey was part of the larger Transportation Energy Futures (TEF) project run by the Department of Energy, Office of Energy Efficiency and Renewable Energy. Of the 206 invitation letters sent, 94 answered all questions in the first round (105 answered at least one question), and 23 of those answered all questions in the second round. 10 of the 23 second round responses were at a discussion section at Asilomar, while the remaining were online. Means and standard deviations of responses from Round One and Two are given in Table 1 below. One main purpose of Delphi surveys is to reduce the variance in opinions through successive rounds of questioning. As shown in Table 1, the standard deviations of 25 of the 30 individual sub-questions decreased between Round One and Round Two, but the decrease was slight in most cases.

  14. Insertion devices

    CERN Document Server

    Bahrdt, J

    2006-01-01

    The interaction of an insertion device with the electron beam in a storage ring is discussed. The radiation property including brightness, ux and polarization of an ideal and real planar and helical / elliptical device is described. The magnet design of planar, helical, quasiperiodic devices and of devices with a reduced on axis power density are resumed.

  15. CAM for Pediatric Pain: What is State-of-the-Research?

    Directory of Open Access Journals (Sweden)

    Jennie C. I. Tsao

    2006-01-01

    Full Text Available Previously, we reviewed the evidence for the efficacy of CAM approaches for pediatric pain (volume 2; issue 2; 2005 using criteria developed by the American Psychological Association Division 12 Task Force. Our review focused on CAM modalities that had been tested with at least one controlled trial or multiple baseline study. In addition, only those trials in which children comprised the study sample were included. Thus, several CAM modalities were not included in our review. Key ethical and other reasons for the limited literature on CAM for pediatric pain as well as directions for future studies are discussed.

  16. Initiating a Reiki or CAM program in a healthcare organization--developing a business plan.

    Science.gov (United States)

    Vitale, Anne

    2014-01-01

    Complementary and alternative medicine (CAM) services, such as Reiki, continue to be offered to consumers in many hospitals and other health care organizations. There is growing interest among nurses, doctors, and other health care providers for the integration of CAM therapies into traditional settings. Health care organizations are responding to this need but may not know how to start CAM programs. Starting a Reiki program in a health care setting must be envisioned in a business model approach. This article introduces nurses and other health care providers to the basic concepts of business plan development and important steps to follow when starting a Reiki or CAM program.

  17. Examining CAM use disclosure using the Behavioral Model of Health Services Use.

    Science.gov (United States)

    Faith, Jennifer; Thorburn, Sheryl; Tippens, Kimberly M

    2013-10-01

    To improve understanding of factors that may influence disclosure of complementary and alternative medicine (CAM) use in the U.S. Cross-sectional survey. Data are from the 2001 Health Care Quality Survey (HCQS), a nationally representative study of adults aged 18 and older living in the continental United States. Using the Behavioral Model of Health Services Use, we conducted multivariate logistic regressions to identify factors associated with disclosing CAM use among the sub-sample of recent CAM users (n=1995). Disclosure of CAM use. Most CAM users (71.0%) disclosed their use of CAM to their doctors. Contextual, individual, and health behavior factors were associated with CAM use disclosure. Of particular interest, disclosure was significantly more likely among those who perceived high quality relationships with their providers (AOR=1.59, CI: 1.01, 2.49) and among those who had a regular source of medical care (AOR=1.54, CI: 1.03, 2.29). The odds of disclosure were also higher among those who used practitioner-provided CAM, with (AOR=2.02, CI: 1.34, 3.06) or without (AOR=1.52, CI: 1.05, 2.20) concurrent herbal medicine use, compared to those who used herbal medicines only. The Behavioral Model of Health Services Use is a useful framework for examining factors that may influence disclosure of CAM use. Further research should examine these relationships using more comprehensive measures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. The use of CAM by women suffering from nausea and vomiting during pregnancy

    Directory of Open Access Journals (Sweden)

    Smith Michael

    2002-05-01

    Full Text Available Abstract Background Nausea and vomiting during pregnancy (NVP affects two-thirds of pregnant women to varying degrees and over the years many modalities have been used to try to alleviate this often debilitating condition. There is a paucity of information in the literature about the use or efficacy of complementary and alternative medicine (CAM for the treatment of this condition that affects so many women. Our primary objective was to examine the prevalence of CAM usage by women suffering from NVP. Our secondary objective was to ascertain if women had any supervision in the use of these treatments. Methods Women who called The Motherisk NVP helpline, were asked after the counseling session to complete a questionnaire, which included demographic data as well as information about their CAM use. Results Seventy women completed the questionnaire. 61% reported using CAM therapies, of which the three most popular were: ginger, vitamin B6 and acupressure. 21% of those who reported using CAM, had consulted CAM practitioners, 8% their physicians or pharmacists and 71% discussed the usage with family, friends and other allied health professionals. Women who did not use CAM stated they would probably use these modalities if there was more information about the safety in pregnancy. Conclusion Pregnant women with NVP are mirroring the trend in the general population of the use of CAM. They are also using CAM therapies with little supervision from practitioners experienced in the use of these modalities.

  19. Polarized targeting of L1-CAM regulates axonal and dendritic bundling in vitro.

    Science.gov (United States)

    Barry, Joshua; Gu, Yuanzheng; Gu, Chen

    2010-11-01

    Proper axonal and dendritic bundling is essential for the establishment of neuronal connections and the synchronization of synaptic inputs, respectively. Cell adhesion molecules of the L1-CAM (L1-cell adhesion molecule) family regulate axon guidance and fasciculation, neuron migration, dendrite morphology, and synaptic plasticity. It remains unclear how these molecules play so many different roles. Here we show that polarized axon-dendrite targeting of an avian L1-CAM protein, NgCAM (neuron-glia cell adhesion molecule), can regulate the switch of bundling of the two major compartments of rat hippocampal neurons. Using a new in-vitro model for studying neurite-neurite interactions, we found that expressed axonal NgCAM induced robust axonal bundling via the trans-homophilic interaction of immunoglobulin domains. Interestingly, dendritic bundling was induced by the dendritic targeting of NgCAM, caused by either deleting its fibronectin repeats or blocking activities of protein kinases. Consistent with the NgCAM results, expression of mouse L1-CAM also induced axonal bundling and blocking kinase activities disrupted its axonal targeting. Furthermore, the trans-homophilic interaction stabilized the bundle formation, probably through recruiting NgCAM proteins to contact sites and promoting guided axon outgrowth. Taken together, our results suggest that precise localization of L1-CAM is important for establishing proper cell-cell contacts in neural circuits.

  20. Mind-body CAM interventions: current status and considerations for integration into clinical health psychology.

    Science.gov (United States)

    Park, Crystal

    2013-01-01

    Complementary and alternative medicine (CAM) is increasingly used for treating myriad health conditions and for maintaining general health. The present article provides an overview of current CAM use with a specific focus on mind-body CAM and its efficacy in treating health conditions. Characteristics of CAM users are presented, and then evidence regarding the efficacy of mind-body treatments (biofeedback, meditation, guided imagery, progressive muscle relaxation, deep breathing, hypnosis, yoga, tai chi, and qi gong) is reviewed. Demographics associated with CAM use are fairly well-established, but less is known about their psychological characteristics. Although the efficacy of mind-body CAM modalities for health conditions is receiving a great deal of research attention, studies have thus far produced a weak base of evidence. Methodological limitations of current research are reviewed. Suggestions are made for future research that will provide more conclusive knowledge regarding efficacy and, ultimately, effectiveness of mind-body CAM. Considerations for clinical applications, including training and competence, ethics, treatment tailoring, prevention efforts, and diversity, conclude the article. Integration of CAM modalities into clinical health psychology can be useful for researchers taking a broader perspective on stress and coping processes, illness behaviors, and culture; for practitioners seeking to incorporate CAM perspectives into their work; and for policy makers in directing healthcare resources wisely. © 2012 Wiley Periodicals, Inc.

  1. The sL1CAM in sera of patients with endometrial and ovarian cancers.

    Science.gov (United States)

    Wojciechowski, Michał; Głowacka, Ewa; Wilczyński, Miłosz; Pękala-Wojciechowska, Anna; Malinowski, Andrzej

    2017-01-01

    L1CAM is a cell adhesion molecule suspected to play an important role in carcinogenesis. The objective of the study was to evaluate the level of soluble L1CAM in the sera of patients with endometrial and ovarian carcinomas and verify the feasibility of the sL1CAM as a marker of these carcinomas. 35 endometrial and 18 ovarian cancer patients were enrolled in the study. 43 patients with benign gynecological conditions constituted a control group. The sL1CAM serum level was measured with ELISA test in each patient and it was referred to the data from the surgical staging of the cancers. The sL1CAM serum level was significantly lower in patients with endometrial cancer than in healthy women and slightly lower in the ovarian cancer group than in the control group. In the endometrial cancer group there was no correlation between sL1CAM concentration and cancer histopathology, stage or grade. sL1CAM concentration positively correlated with ovarian cancer stage and (not significantly) with grade. Despite the increasing data about the possible role of L1CAM as a strong prognostic factor of poor outcome in many cancers, we did not find evidence supporting the use of sL1CAM as a marker of endometrial or ovarian cancers.

  2. Effects of EpCAM overexpression on human breast cancer cell lines

    Directory of Open Access Journals (Sweden)

    Krobitsch Sylvia

    2011-01-01

    Full Text Available Abstract Background Recently, EpCAM has attracted major interest as a target for antibody- and vaccine-based cancer immunotherapies. In breast cancer, the EpCAM antigen is overexpressed in 30-40% of all cases and this increased expression correlates with poor prognosis. The use of EpCAM-specific monoclonal antibodies is a promising treatment approach in these patients. Methods In order to explore molecular changes following EpCAM overexpression, we investigated changes of the transcriptome upon EpCAM gene expression in commercially available human breast cancer cells lines Hs578T and MDA-MB-231. To assess cell proliferation, a tetrazolium salt based assay was performed. A TCF/LEF Reporter Kit was used to measure the transcriptional activity of the Wnt/β-catenin pathway. To evaluate the accumulation of β-catenin in the nucleus, a subcellular fractionation assay was performed. Results For the first time we could show that expression profiling data of EpCAM transfected cell lines Hs578TEpCAM and MDA-MB-231EpCAM indicate an association of EpCAM overexpression with the downregulation of the Wnt signaling inhibitors SFRP1 and TCF7L2. Confirmation of increased Wnt signaling was provided by a TCF/LEF reporter kit and by the finding of the nuclear accumulation of ß-catenin for MDA-MB-231EpCAM but not Hs578TEpCAM cells. In Hs578T cells, an increase of proliferation and chemosensitivity to Docetaxel was associated with EpCAM overexpression. Conclusions These data show a cell type dependent modification of Wnt signaling components after EpCAM overexpression in breast cancer cell lines, which results in marginal functional changes. Further investigations on the interaction of EpCAM with SFRP1 and TCF7L2 and on additional factors, which may be causal for changes upon EpCAM overexpression, will help to characterize unique molecular properties of EpCAM-positive breast cancer cells.

  3. A simple method of image analysis to estimate CAM vascularization by APERIO ImageScope software.

    Science.gov (United States)

    Marinaccio, Christian; Ribatti, Domenico

    2015-01-01

    The chick chorioallantoic membrane (CAM) assay is a well-established method to test the angiogenic stimulation or inhibition induced by molecules and cells administered onto the CAM. The quantification of blood vessels in the CAM assay relies on a semi-manual image analysis approach which can be time consuming when considering large experimental groups. Therefore we present here a simple and fast volumetric method to inspect differences in vascularization between experimental conditions related to the stimulation and inhibition of CAM angiogenesis based on the Positive Pixel Count algorithm embedded in the APERIO ImageScope software.

  4. Chick ex ovo culture and ex ovo CAM assay: how it really works

    National Research Council Canada - National Science Library

    Dohle, Daniel S; Pasa, Susanne D; Gustmann, Sebastian; Laub, Markus; Wissler, Josef H; Jennissen, Herbert P; Dünker, Nicole

    2009-01-01

    .... After the chick chorioallantoic membrane (CAM) has developed, its blood vessel network can be easily accessed, manipulated and observed and therefore provides an optimal setting for angiogenesis assays...

  5. ON DESIGN METHOD OF THE PRECISION CAM PROFILE WITH RANDOM PROCESSING ERRORS

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Based on probability and statistic, a design method of precision cam profile concerning the influence of random processing errors is advanced. Combining the design with the process, which can be used to predict that cam profiles will be successfully processed or not in the design stage, design of the cam can be done by balancing the economization and reliability. In addition, an fuzzy deduction method based on Bayers formula is advanced to estimate processing reasonable of the designed precision cam profile, and it take few samples.

  6. Complementary and alternative medicine (CAM) as part of primary health care in Germany-comparison of patients consulting general practitioners and CAM practitioners: a cross-sectional study.

    Science.gov (United States)

    Krug, Katja; Kraus, Katharina I; Herrmann, Kathrin; Joos, Stefanie

    2016-10-24

    In Germany, complementary and alternative medicine (CAM) in primary health care is offered by general practitioners (GPs) and by natural health practitioners, so called 'Heilpraktiker' (HPs). Considering the steadily growing number of unregulated HPs, the aim of the study was to assess characteristics of patients consulting HPs in comparison to patients consulting GPs. In a cross-sectional study, patients of randomly selected GPs and HPs were asked to complete a questionnaire about their health care status, health care behavior, and symptoms rated on the Measure Yourself Medical Outcome Profile (MYMOP-D). Patient groups were compared based on health care provider (HP, GP with high use of CAM (CAM-GP), and GP with no/little use of CAM (nCAM-GP)) using Kruskal-Wallis tests and analyses of variance (ANOVA). Altogether, 567 patients (91 of 11 HPs, 223 of 15 CAM-GPs, 253 of 19 nCAM-GPs) filled in the questionnaire. Patients of HPs had a higher education level and were more often female. The most common reason for encounter among all three groups were musculoskeletal problems (30.2-31.1 %). Patients seeing HPs reported more psychological (4.4 % vs. 17.8 %), but less respiratory problems (19.9 % vs. 7.8 %), and longer symptom duration (>5 years: 21.1 % vs. 40.7 %), than patients of nCAM-GPs. The high percentage of patients with psychological illness and chronic health problems consulting HPs demonstrates the urgent need for action with regard to CAM therapy in primary care and regulation of natural health practitioners. Appropriate measures with regard to quality and patient safety should be taken given the growing numbers of HPs and the absence of a regulatory body.

  7. On understanding the very different science premises meaningful to CAM versus orthodox medicine: part I--the fundamentals.

    Science.gov (United States)

    Tiller, William A

    2010-03-01

    In previous articles by this author and his colleagues in the Journal of Alternative and Complementary Medicine, it has been shown that physical reality consists of two uniquely different categories of substance, one being electric charge-based while the other appears to be magnetic charge-based. Normally, only the electric atom/molecule type of substance is accessible by our traditional measurement instruments. We label this condition as the uncoupled state of physical reality that is our long-studied, electric atom/molecule level of nature. The second level of physical reality is invisible to traditional measurement instruments when the system is in the uncoupled state but is accessible to these same instruments when the system is in the coupled state of physical reality. The coupling of these two unique levels has been shown to occur via the application of a sufficient intensity of human consciousness in the form of specific intentions. Part II of this article (in a forthcoming issue) explores the thermodynamics of complementary and 328 alternative medicine (CAM) through five different space-time applications involving coupled state physics to show their relevance to today's medicine: (1) homeopathy; (2) the placebo effect; (3) long-range, room temperature, macroscopic-size-scale, information entanglement; (4) explanation for dark matter/energy plus possible human levitation; and (5) electrodermal diagnostic devices. The purpose is to clearly differentiate the use and limitations of uncoupled state physics in nature and today's traditional medicine from coupled state physics in tomorrow's CAM. Existing orthodox science provides the technical underpinnings and mindset for today's orthodox medicine. Psycho-energetic science will provide the technical underpinnings and mindset for CAM.

  8. Fatigue resistance of CAD/CAM resin composite molar crowns.

    Science.gov (United States)

    Shembish, Fatma A; Tong, Hui; Kaizer, Marina; Janal, Malvin N; Thompson, Van P; Opdam, Niek J; Zhang, Yu

    2016-04-01

    To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. Fully anatomically shaped monolithic resin composite molar crowns (Lava Ultimate, n=24) and leucite reinforced glass-ceramic crowns (IPS Empress CAD, n=24) were fabricated using CAD/CAM systems. Crowns were cemented on aged dentin-like resin composite tooth replicas (Filtek Z100) with resin-based cements (RelyX Ultimate for Lava Ultimate or Multilink Automix for IPS Empress). Three step-stress profiles (aggressive, moderate and mild) were employed for the accelerated sliding-contact mouth-motion fatigue test. Twenty one crowns from each group were randomly distributed among these three profiles (1:2:4). Failure was designated as chip-off or bulk fracture. Optical and electron microscopes were used to examine the occlusal surface and subsurface damages, as well as the material microstructures. The resin composite crowns showed only minor occlusal damage during mouth-motion step-stress fatigue loading up to 1700N. Cross-sectional views revealed contact-induced cone cracks in all specimens, and flexural radial cracks in 2 crowns. Both cone and radial cracks were relatively small compared to the crown thickness. Extending these cracks to the threshold for catastrophic failure would require much higher indentation loads or more loading cycles. In contrast, all of the glass-ceramic crowns fractured, starting at loads of approximately 450N. Monolithic CAD/CAM resin composite crowns endure, with only superficial damage, fatigue loads 3-4 times higher than those causing catastrophic failure in glass-ceramic CAD crowns. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Optical properties of CAD-CAM ceramic systems.

    Science.gov (United States)

    Della Bona, Alvaro; Nogueira, Audrea D; Pecho, Oscar E

    2014-09-01

    To evaluate the direct transmittance (T%), translucency, opacity and opalescence of CAD-CAM ceramic systems and the correlation between the translucency parameter (TP) and the contrast ratio (CR). Specimens of shades A1, A2 and A3 (n=5) were fabricated from CAD-CAM ceramic blocks (IPS e.max(®) CAD HT and LT, IPS Empress(®) CAD HT and LT, Paradigm™ C, and VITABLOCS(®) Mark II) and polished to 1.0±0.01mm in thickness. A spectrophotometer (Lambda 20) was used to measure T% on the wavelength range of 400-780nm. Another spectrophotometer (VITA Easyshade(®) Advance) was used to measure the CIE L(*)a(*)b(*) coordinates and the reflectance value (Y) of samples on white and black backgrounds. TP, CR and the opalescence parameter (OP) were calculated. Data were statistically analysed using VAF (variance accounting for) coefficient with Cauchy-Schwarz inequality, one-way ANOVA, Tukey's test, Bonferroni correction and Pearson's correlation. T% of some ceramic systems is dependent on the wavelength. The spectral behaviour showed a slight and constant increase in T% up to approximately 550nm, then some ceramics changed the behaviour as the wavelength gets longer. TP and CR values ranged, respectively, from 16.79 to 21.69 and from 0.52 to 0.64 (r(2)=-0.97). OP values ranged from 3.01 to 7.64. The microstructure of CAD-CAM ceramic systems influenced the optical properties. TP and CR showed a strong correlation for all ceramic systems evaluated. Yet, all ceramics showed some degree of light transmittance. In addition to shade, this study showed that other optical properties influence on the natural appearance of dental ceramics. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. CAD/CAM and scientific data management at Dassault

    Science.gov (United States)

    Bohn, P.

    1984-01-01

    The history of CAD/CAM and scientific data management at Dassault are presented. Emphasis is put on the targets of the now commercially available software CATIA. The links with scientific computations such as aerodynamics and structural analysis are presented. Comments are made on the principles followed within the company. The consequences of the approximative nature of scientific data are examined. Consequence of the new history function is mainly its protection against copy or alteration. Future plans at Dassault for scientific data appear to be in opposite directions compared to some general tendencies.

  11. Experimental and analytical investigation of finger-follower cam systems

    Science.gov (United States)

    Hsu, Wensyang

    A predictive dynamic model to compute the motions of components in cam systems, along with the experimental work to verify the model are described. The major components in finger-follower cam systems include the cam, the follower, the hydraulic lash adjuster, and the valve spring, equipped sometimes with a helical valve spring cup damper. In order to fully describe the dynamics of such a system, a lumped/distributed parameter model for the finger-follower cam system with a moving follower pivot is proposed. The valve spring is modeled as a distributed parameter element, and the adjuster is modeled as a stiff spring with viscous damping. The coulomb friction combined with viscous damping between sliding surfaces are also considered. The model predicts toss between the adjuster and the follower at 2535 rpm, and experiment indicates toss starting at 2520 rpm. It is found by simulation that designing hydraulic lash adjuster to be as rigid as possible is essential to successful high speed operation of finger-follower valve trains because a 50 percent decrease in the compliance of the adjuster could increase the maximum camshaft operating speed 150 rpm. Total elimination of the hydraulic lash adjuster is not always feasible because hydraulic lash adjusters can eliminate the clearance between components and do not need to be mechanically, manually adjusted. In order to provide a more stable and precise description on the dynamic response of the adjuster, a two-mode dynamic model for the adjuster is proposed by considering the oil compressibility in the oil chamber, as well as the oil leakage through the annular gap. Furthermore, the effect due to the oil flow from the central orifice to the oil chamber is also studied analytically and experimentally. The inertia effects of the helical valve spring can be suppressed by a cup damper. Damping between the damper and spring wire is found to depend only weakly on relative sliding velocity. The current formula in computing

  12. Relevant Applications of Tools in UG NX CAM Module

    Directory of Open Access Journals (Sweden)

    Zhang En Guang

    2016-01-01

    Full Text Available In this paper, the methods to establish the custom magazine have been proposed while the UG NX CAM module is employed to conduct the CNC milling programming. At the same time, how to set the parameters of the cutting tool has been also analyzed; in the creation of tools, the use of shank and holder as well as the use of handle check functions in NC machining has been introduced; meanwhile, the secondary rough machining of corner and the application of clean-cut features have been discussed.

  13. Applying DER-CAM for IIT Microgrid Explansion Planning

    Energy Technology Data Exchange (ETDEWEB)

    Shahidehpour, Mohammad [Illinois Inst. of Technology, Chicago, IL (United States); Li, Zuyi [Illinois Inst. of Technology, Chicago, IL (United States); Wang, Jianhui [Argonne National Lab. (ANL), Argonne, IL (United States); Chen, Chen [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-04-19

    The Distributed Energy Resources Customer Adoption Model (DER-CAM) is an economic and environmental model of customer DER adoption. This model has been in development at the Lawrence Berkeley National Laboratory since 2000. The objective of the model is to find optimal DER investments while minimizing total energy costs or carbon dioxide (CO2) emissions, or achieving a weighted objective that simultaneously considers both criteria. The Illinois Institute of Technology (IIT) Microgrid project started in August 2008, and the majority of the project was completed in May 2013. IIT Microgrid, funded mostly by a grant from the U.S. Department of Energy as well as State and philanthropic contributions, empowers the campus consumers with the objective of establishing a smart microgrid that is highly reliable, economically viable, environmentally friendly, fuel-efficient, and resilient in extreme circumstances with a self-healing capability. In this project, we apply DER-CAM to study the expansion planning of the IIT Microgrid. First, the load data, environmental data, utility data, and technology data for the IIT Microgrid are gathered and organized to follow the DER-CAM input requirements. Then, DERCAM is applied to study the expansion planning of the IIT Microgrid for different cases, where different objectives in DER-CAM and different utility conditions are tested. Case 1 considers the objective of minimizing energy costs with fixed utility rates and 100% electric utility availability. Case 2 considers the objective of minimizing energy costs with real-time utility rates and 4 emergency weeks when the IIT Microgrid does not have access to the electric utility grid and has to operate in island mode. In Case 3, the utility rates are restored to fixed values and 100% electric utility availability is assumed, but a weighted multi-objective (Obj: a × costs + b × CO2 emissions, where a and b are weights for cost minimization and CO2 emissions minimization) is utilized to

  14. CAD/CAM and scientific data management at Dassault

    Science.gov (United States)

    Bohn, P.

    1984-01-01

    The history of CAD/CAM and scientific data management at Dassault are presented. Emphasis is put on the targets of the now commercially available software CATIA. The links with scientific computations such as aerodynamics and structural analysis are presented. Comments are made on the principles followed within the company. The consequences of the approximative nature of scientific data are examined. Consequence of the new history function is mainly its protection against copy or alteration. Future plans at Dassault for scientific data appear to be in opposite directions compared to some general tendencies.

  15. CAD/CAM from the graphic-design perspective

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, A.

    1982-11-01

    CAD/CAM systems have evolved elaborate human-computer interfaces in order to facilitate the creation of highly detailed and specialized schematic diagrams and texts. Although these systems have powerful capacities in terms of graphics editing, data manipulation, and data storage, insufficient attention has been given to making the online interface (together with supporting documentation) user-friendly, i.e., understandable, memorable, and appealing to the general user. Graphic-design considerations in particular have been routinely overlooked. Graphic design concerns typography, symbol design, color, spatial layout, and temporal sequencing. Graphic design can assist computer science by providing insight and expertise in designing effective communication between human being and machine.

  16. Biofuel crops with CAM photosynthesis: Economic potential on moisture-limited lands

    Science.gov (United States)

    Bartlett, Mark; Hartzell, Samantha; Porporato, Amilcare

    2017-04-01

    As the demand for food and renewable energy increases, the intelligent utilization of marginal lands is becoming increasingly critical. In marginal lands classified by limited rainfall or soil salinity, the cultivation of traditional C3 and C4 photosynthesis crops often is economically infeasible. However, in such lands, nontraditional crops with crassulacean acid metabolism (CAM) photosynthesis show great economic potential for cultivation. CAM crops including Opuntia (prickly pear) and Ananas (pineapple) achieve a water use efficiency which is three fold higher than C4 crops such as corn and 6-fold higher than C3 crops such as wheat, leading to a comparable annual productivity with only 20% of the water demand. This feature, combined with a shallow rooting depth and a high water storage capacity, allows CAM plants to take advantage of small, infrequent rainfall amounts in shallow, quickly draining soils. Furthermore, CAM plants typically have properties (e.g., high content of non-structural carbohydrates) that are favorable for biofuel production. Here, for marginal lands characterized by low soil moisture availability and/or high salinity, we assess the potential productivity and economic benefits of CAM plants. CAM productivity is estimated using a recently developed model which simulates CAM photosynthesis under a range of soil and climate conditions. From these results, we compare the energy and water resource inputs required by CAM plants to those required by more traditional C3 and C4 crops (corn, wheat, sorghum), and we evaluate the economic potential of CAM crops as sources of food, fodder, or biofuel in marginal soils. As precipitation events become more intense and infrequent, we show that even though marginal land area may increase, CAM crop cultivation shows great promise for maintaining high productivity with minimal water inputs. Our analysis indicates that on marginal lands, widespread cultivation of CAM crops as biofuel feedstock may help

  17. Neural Cell Adhesion Molecule NrCAM Regulates Semaphorin 3F-Induced Dendritic Spine Remodeling

    Science.gov (United States)

    Demyanenko, Galina P.; Mohan, Vishwa; Zhang, Xuying; Brennaman, Leann H.; Dharbal, Katherine E.S.; Tran, Tracy S.; Manis, Paul B.

    2014-01-01

    Neuron-glial related cell adhesion molecule (NrCAM) is a regulator of axon growth and repellent guidance, and has been implicated in autism spectrum disorders. Here a novel postsynaptic role for NrCAM in Semaphorin3F (Sema3F)-induced dendritic spine remodeling was identified in pyramidal neurons of the primary visual cortex (V1). NrCAM localized to dendritic spines of star pyramidal cells in postnatal V1, where it was coexpressed with Sema3F. NrCAM deletion in mice resulted in elevated spine densities on apical dendrites of star pyramidal cells at both postnatal and adult stages, and electron microscopy revealed increased numbers of asymmetric synapses in layer 4 of V1. Whole-cell recordings in cortical slices from NrCAM-null mice revealed increased frequency of mEPSCs in star pyramidal neurons. Recombinant Sema3F-Fc protein induced spine retraction on apical dendrites of wild-type, but not NrCAM-null cortical neurons in culture, while re-expression of NrCAM rescued the spine retraction response. NrCAM formed a complex in brain with Sema3F receptor subunits Neuropilin-2 (Npn-2) and PlexinA3 (PlexA3) through an Npn-2-binding sequence (TARNER) in the extracellular Ig1 domain. A trans heterozygous genetic interaction test demonstrated that Sema3F and NrCAM pathways interacted in vivo to regulate spine density in star pyramidal neurons. These findings reveal NrCAM as a novel postnatal regulator of dendritic spine density in cortical pyramidal neurons, and an integral component of the Sema3F receptor complex. The results implicate NrCAM as a contributor to excitatory/inhibitory balance in neocortical circuits. PMID:25143608

  18. Retrofitting a crown to a sleep apnea device by using computer-aided design and computer-aided milling technology.

    Science.gov (United States)

    Biethman, Rick; Land, Martin F; Hruskocy, Heather; Colgin, Bruce

    2014-07-01

    Retrofitting a new crown to an existing dental device is challenging. The continued evolution of computer-aided design and computer-aided manufacturing (CAD/CAM) significantly simplifies the process. This article demonstrates retrofitting a gold crown to an existing sleep apnea device.

  19. A Prospective, Multicenter Study of Complementary/Alternative Medicine (CAM) Utilization During Definitive Radiation for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Moran, Meena S., E-mail: meena.moran@yale.edu [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Department of Radiation Therapy, William W. Backus Hospital, Norwich, Connecticut (United States); Ma Shuangge [Department of Epidemiology and Public Health, Yale University, New Haven, Connecticut (United States); Jagsi, Reshma [University of Michigan, Department of Radiation Oncology, Ann Arbor, MI (United States); Yang, Tzu-I Jonathan [Yale University School of Medicine, New Haven, Connecticut (United States); Higgins, Susan A. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Department of Radiation Therapy, Shoreline Medical Center, Guilford, Connecticut (United States); Weidhaas, Joanne B. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Wilson, Lynn D. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Department of Radiation Therapy, Lawrence and Memorial Hospital, New London, Connecticut (United States); Lloyd, Shane [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Peschel, Richard [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); Department of Radiation Therapy, Lawrence and Memorial Hospital, New London, Connecticut (United States); Gaudreau, Bryant [Department of Radiation Therapy, William W. Backus Hospital, Norwich, Connecticut (United States); Rockwell, Sara [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States)

    2013-01-01

    Purpose: Although complementary and alternative medicine (CAM) utilization in breast cancer patients is reported to be high, there are few data on CAM practices in breast patients specifically during radiation. This prospective, multi-institutional study was conducted to define CAM utilization in breast cancer during definitive radiation. Materials/Methods: A validated CAM instrument with a self-skin assessment was administered to 360 Stage 0-III breast cancer patients from 5 centers during the last week of radiation. All data were analyzed to detect significant differences between users/nonusers. Results: CAM usage was reported in 54% of the study cohort (n=194/360). Of CAM users, 71% reported activity-based CAM (eg, Reiki, meditation), 26% topical CAM, and 45% oral CAM. Only 16% received advice/counseling from naturopathic/homeopathic/medical professionals before initiating CAM. CAM use significantly correlated with higher education level (P<.001), inversely correlated with concomitant hormone/radiation therapy use (P=.010), with a trend toward greater use in younger patients (P=.066). On multivariate analysis, level of education (OR: 6.821, 95% CI: 2.307-20.168, P<.001) and hormones/radiation therapy (OR: 0.573, 95% CI: 0.347-0.949, P=.031) independently predicted for CAM use. Significantly lower skin toxicity scores were reported in CAM users vs nonusers, respectively (mild: 34% vs 25%, severe: 17% vs 29%, P=.017). Conclusion: This is the first prospective study to assess CAM practices in breast patients during radiation, with definition of these practices as the first step for future investigation of CAM/radiation interactions. These results should alert radiation oncologists that a large percentage of breast cancer patients use CAM during radiation without disclosure or consideration for potential interactions, and should encourage increased awareness, communication, and documentation of CAM practices in patients undergoing radiation treatment for breast

  20. Preparation and Preliminary Application of MAdCAM-1 Polyclonal Antibody in Dairy Cows with Subclinical Mastitis.

    Science.gov (United States)

    Xu, Chuang; Chen, Yuanyuan; Chang, Qiaocheng; Xia, Cheng; Yang, Wei; Zhang, Hongyou

    2015-08-01

    MAdCAM-1 plays an important role in mediating immune response and inflammation. This study aimed to express and purify a fusion protein of MAdCAM-1 in prokaryotic cells and to prepare rat anti-bovine MAdCAM-1 polyclonal antibodies. Prokaryotic expression vector pGEX-4T-1-MAdCAM-1 and pET-28a-MAdCAM-1 were constructed, respectively. The above plasmids were transformed into BL21 Escherichia coli strain. These recombinant strains were induced by IPTG and identified by Western blot analysis and SDS-PAGE. Wistar rats were immunized with recombinant protein (pET-28a-MAdCAM-1) emulsified with Freund's adjuvant, and antibody titers were measured by indirect ELISA. Antibody titers reached the highest value (1:128,000) after the third immunization. Western blot showed that rat anti-bovine MAdCAM-1 polyclonal antibody can not only recognize recombinant MAdCAM-1 protein expressed in E. coli but also recognizes natural MAdCAM-1 protein extracted from bovine tissues. However, commercial anti-mouse MAdCAM-1 monoclonal antibodies did not recognize the recombinant MAdCAM-1 protein or natural protein, which indicated no cross-reactivity between bovine MAdCAM-1 and mouse MAdCAM-1. Real-time fluorescence quantitative polymerase chain reaction and Western blot analysis showed that MAdCAM-1 expression was limited in mammary lymphoid nodes of subclinical mastitis in dairy cows. We speculate that MAdCAM-1 expression is inconsistent in different periods of the dairy cows. The successful preparation of rat anti-bovine MAdCAM-1 polyclonal antibody and its preliminary application in dairy cows provide the foundation for further study of the mechanism of anti-inflammation of MAdCAM-1 in dairy cows with subclinical mastitis.

  1. Disclosure of Complementary and Alternative Medicine to Conventional Medical Providers: Variation by Race/Ethnicity and Type of CAM

    Science.gov (United States)

    Chao, Maria T.; Wade, Christine; Kronenberg, Fredi

    2009-01-01

    Background Complementary and alternative medicine (CAM) is often used alongside conventional medical care, yet fewer than half of patients disclose CAM use to medical doctors. CAM disclosure is particularly low among racial/ethnic minorities, but reasons for differences, such as type of CAM used or quality of conventional healthcare, have not been explored. Objective We tested the hypotheses that disclosure of CAM use to medical doctors is higher for provider-based CAM and among non-Hispanic whites, and that access to and quality of conventional medical care account for racial/ethnic differences in CAM disclosure. Methods Bivariate and multiple variable analyses of the 2002 National Health Interview Survey and 2001 Health Care Quality Survey were performed. Results Disclosure of CAM use to medical providers was higher for provider-based than self-care CAM. Disclosure of any CAM was associated with access to and quality of conventional care and higher among non-Latino whites relative to minorities. Having a regular doctor and quality patient–provider relationship mitigated racial/ethnic differences in CAM disclosure. Conclusion Insufficient disclosure of CAM use to conventional providers, particularly for self-care practices and among minority populations, represents a serious challenge in medical encounter communications. Efforts to improve disclosure of CAM use should be aimed at improving consistency of care and patient–physician communication across racial/ethnic groups. PMID:19024232

  2. Status of the CAMS-BeNeLux network

    Science.gov (United States)

    Roggemans, P.; Johannink, C.; Breukers, M.

    2016-01-01

    An overview is being given of the further expansion of the CAMS@BeNeLux network since previous IMC, July 2015 until May 2016. The weather proved less favorable than in the year before, but thanks to a number of new cameras and extra observing stations, the overall performance of the network remained at the same level in spite of the often poor weather circumstances. This paper compares the Kappa-Cygnids performance of 2015 with the analyses made for the 2014 data, following the same methodology. In 2015 the Kappa Cygnids were remarkable absent which confirms the periodic nature of the abundant Kappa-Cygnids display in 2014. The CAMS@BeNeLux network was the first to draw attention to enhanced activity of the newly discovered Chi Cygnids meteor shower with 5 accurate orbits in the night of 14-15 September 2015. A search through a selection of all orbits of September 2015 yield 71 possible Chi Cygnid orbits of which 18 were selected to calculate the average orbital elements.

  3. Removal of trimethylamine (fishy odor) by C₃ and CAM plants.

    Science.gov (United States)

    Boraphech, Phattara; Thiravetyan, Paitip

    2015-08-01

    From screening 23 plant species, it was found that Pterocarpus indicus (C3) and Sansevieria trifasciata (crassulacean acid metabolism (CAM)) were the most effective in polar gaseous trimethylamine (TMA) uptake, reaching up to 90% uptake of initial TMA (100 ppm) within 8 h, and could remove TMA at cycles 1-4 without affecting photosystem II (PSII) photochemistry. Up to 55 and 45% of TMA was taken up by S. trifasciata stomata and leaf epicuticular wax, respectively. During cycles 1-4, interestingly, S. trifasciata changed its stomata apertures, which was directly induced by gaseous TMA and light treatments. In contrast, for P. indicus the leaf epicuticular wax and stem were the major pathways of TMA removal, followed by stomata; these pathways accounted for 46, 46, and 8%, respectively, of TMA removal percentages. Fatty acids, particularly tetradecanoic (C14) acid and octadecanoic (C18) acid, were found to be the main cuticular wax components in both plants, and were associated with TMA removal ability. Moreover, the plants could degrade TMA via multiple metabolic pathways associated with carbon/nitrogen interactions. In CAM plants, one of the crucial pathways enabled 78% of TMA to be transformed directly to dimethylamine (DMA) and methylamine (MA), which differed from C3 plant pathways. Various metabolites were also produced for further detoxification and mineralization so that TMA was completely degraded by plants.

  4. CamShift Tracking Method Based on Target Decomposition

    Directory of Open Access Journals (Sweden)

    Chunbo Xiu

    2015-01-01

    Full Text Available In order to avoid the inaccurate location or the failure tracking caused by the occlusion or the pose variation, a novel tracking method is proposed based on CamShift algorithm by decomposing the target into multiple subtargets for location separately. Distance correlation matrices are constructed by the subtarget sets in the template image and the scene image to evaluate the correctness of the location results. The error locations of the subtargets can be corrected by resolving the optimization function constructed according to the relative positions among the subtargets. The directions and sizes of the correctly located subtargets with CamShift algorithm are updated to reduce the disturbance of the background in the tracking progress. Simulation results show that the method can perform the location and tracking of the target and has better adaptability to the scaling, translation, rotation, and occlusion. Furthermore, the computational cost of the method increases slightly, and its average tracking computational time of the single frame is less than 25 ms, which can meet the real-time requirement of the TV tracking system.

  5. SR-4000 and CamCube3.0 Time of Flight (ToF Cameras: Tests and Comparison

    Directory of Open Access Journals (Sweden)

    Fulvio Rinaudo

    2012-04-01

    Full Text Available In this paper experimental comparisons between two Time-of-Flight (ToF cameras are reported in order to test their performance and to give some procedures for testing data delivered by this kind of technology. In particular, the SR-4000 camera by Mesa Imaging AG and the CamCube3.0 by PMD Technologies have been evaluated since they have good performances and are well known to researchers dealing with Time-of-Flight (ToF cameras. After a brief overview of commercial ToF cameras available on the market and the main specifications of the tested devices, two topics are presented in this paper. First, the influence of camera warm-up on distance measurement is analyzed: a warm-up of 40 minutes is suggested to obtain the measurement stability, especially in the case of the CamCube3.0 camera, that exhibits distance measurement variations of several centimeters. Secondly, the variation of distance measurement precision variation over integration time is presented: distance measurement precisions of some millimeters are obtained in both cases. Finally, a comparison between the two cameras based on the experiments and some information about future work on evaluation of sunlight influence on distance measurements are reported.

  6. Interaction using nearby-and-far projection surfaces with a body-worn ProCam system

    Science.gov (United States)

    Kurata, Takeshi; Sakata, Nobuchika; Kourogi, Masakatsu; Okuma, Takashi; Ohta, Yuichi

    2008-02-01

    We have been developing a wearable interface system, "BOWL ProCam (BOdy-Worn Laser Projector Camera)", for providing the user with a mixed-reality interface by not using any head-mounted devices. The BOWL ProCam is equipped with a laser projector that has the long focal depth, a high-definition fish-eye camera for enabling wide-range situation understanding, and attitude sensors for projection stabilization. In this paper, we first show an evaluation by simulation on the proper position for wearing a projector-camera system in the context of real-world task support. According to the result, the upper chest area was selected as the wearing position. Next, we briefly describe interaction techniques effectively employing both nearby projection surfaces such as the user's hands and far projection surfaces such as a tabletop and wall. This paper then presents preliminary experiments on active-stereo and hand-posture-classification techniques to realize such interaction with a proof-of-concept system that uses a conventional light-bulb projector.

  7. ChemCam Education and Public Outreach: Zapping the Public into Awareness of ChemCam, the Mars Science Laboratory, and Mars Science and Exploration

    Science.gov (United States)

    Shaner, A. J.; Shipp, S. S.; Wiens, R. C.; Maurice, S.; Gasnault, O.; Newsom, H.; Anderson, R.

    2012-03-01

    The Chemistry and Camera (ChemCam) instrument EPO program utilizes a public website and educator professional development to capture the public’s interest and imagination in Mars science and exploration.

  8. 基于逆向工程技术圆柱凸轮机构的CAD/CAM%CAD/CAM of cylindrical cam mechanism based on re-verse engineering technology

    Institute of Scientific and Technical Information of China (English)

    蒋萌; 葛正浩; 屈毅; 李艳妮

    2011-01-01

    The papeer presents a new process and method of revere design and manufacturing of the cylindrical cam mechanism.By applying the Coordinate Measuring Machine (CMM) and the PRO/E software as the platform to carry out aided design, by taking Microsoft Visual C + + 6.0 as the development tool, and based on Windows platform, the cylindrical cam mechanism dealgn and manufacturing software is generated, allowing the design of cycle map and cam profile, checking the pressure angle and curvature radius rapidly, almulating the motion of cam. And the NC machining codes which can be directly used for numerical control machine were generated, achieviug the integration of design and manufacture of cylindrical cam mechanism. This CAD/CAM system can not only be applied in the reverse design of cylindrical cam mechanism, but alao used to achieve the forward de-sign of cylindrical ,cam mechanism quickly and easily. Finally, by taking reverse, design and manufacture of the cylindrical indexing cam as an example, the reverse design and manufacturing process and method of cylindrical cam mechanism based on reverse engineering technology has been explained in detail.%介绍了圆柱凸轮机构逆向设计与制造的流程和方法.利用三坐标测量机和Pro/E软件为平台实现辅助设计,以Microsolft Visual C++6.0为开发工具,基于Windows平台编制了圆柱凸轮机构设计与制造软件,实现了圆柱凸轮机构的循环图和轮廓设计,并可进行压力角及曲率半径的快速校核和凸轮的运动仿真,生成了直接用于数控机床的刀具NC加工代码,实现了圆柱凸轮机构设计制造一体化.此CAD/CAM系统不仅可用于圆柱凸轮机构的反求设计,亦可简单快捷地实现圆柱凸轮机构的正向设计.文中以圆柱分度凸轮的反求与制造为例详细说明了基于逆向工程技术圆柱凸轮机构的设计与制造方法和流程.

  9. The ExoMars PanCam Instrument

    Science.gov (United States)

    Griffiths, Andrew; Coates, Andrew; Muller, Jan-Peter; Jaumann, Ralf; Josset, Jean-Luc; Paar, Gerhard; Barnes, David

    2010-05-01

    The ExoMars mission has evolved into a joint European-US mission to deliver a trace gas orbiter and a pair of rovers to Mars in 2016 and 2018 respectively. The European rover will carry the Pasteur exobiology payload including the 1.56 kg Panoramic Camera. PanCam will provide multispectral stereo images with 34 deg horizontal field-of-view (580 microrad/pixel) Wide-Angle Cameras (WAC) and (83 microrad/pixel) colour monoscopic "zoom" images with 5 deg horizontal field-of-view High Resolution Camera (HRC). The stereo Wide Angle Cameras (WAC) are based on Beagle 2 Stereo Camera System heritage [1]. Integrated with the WACs and HRC into the PanCam optical bench (which helps the instrument meet its planetary protection requirements) is the PanCam interface unit (PIU); which provides image storage, a Spacewire interface to the rover and DC-DC power conversion. The Panoramic Camera instrument is designed to fulfil the digital terrain mapping requirements of the mission [2] as well as providing multispectral geological imaging, colour and stereo panoramic images and solar images for water vapour abundance and dust optical depth measurements. The High Resolution Camera (HRC) can be used for high resolution imaging of interesting targets detected in the WAC panoramas and of inaccessible locations on crater or valley walls. Additionally HRC will be used to observe retrieved subsurface samples before ingestion into the rest of the Pasteur payload. In short, PanCam provides the overview and context for the ExoMars experiment locations, required to enable the exobiology aims of the mission. In addition to these baseline capabilities further enhancements are possible to PanCam to enhance it's effectiveness for astrobiology and planetary exploration: 1. Rover Inspection Mirror (RIM) 2. Organics Detection by Fluorescence Excitation (ODFE) LEDs [3-6] 3. UVIS broadband UV Flux and Opacity Determination (UVFOD) photodiode This paper will discuss the scientific objectives and resource

  10. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  11. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  12. Concentration device

    DEFF Research Database (Denmark)

    2013-01-01

    A concentration device (2) for filter filtration concentration of particles (4) from a volume of a fluid (6). The concentration device (2) comprises a filter (8) configured to filter particles (4) of a predefined size in the volume of the fluid (6). The concentration device (2) comprises...

  13. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  14. Use of Complementary and Alternative Medicine (CAM) Treatments by Parents of Children with Autism Spectrum Disorders

    Science.gov (United States)

    Christon, Lillian M.; Mackintosh, Virginia H.; Myers, Barbara J.

    2010-01-01

    Parents of children with autism spectrum disorders (ASDs) may elect to use complementary and alternative medicine (CAM) treatments with their children in place of, or in addition to, conventional treatments. CAM treatments are controversial and understudied and, for most, the efficacy has not been established. The current study (n = 248) examined…

  15. A methodological framework for evaluating the evidence for Complementary and Alternative Medicine (CAM) for cancer

    DEFF Research Database (Denmark)

    Zachariae, Robert; Johannesen, Helle

    2011-01-01

    In spite of lacking evidence for effects on cancer progression itself, an increasing number of cancer patients use various types of complementary and alternative medicine (CAM). There is disagreement between CAM practitioners, researchers and clinical oncologists, as to how evidence concerning...

  16. A new radiological index for assessing asphericity of the femoral head in cam impingement

    DEFF Research Database (Denmark)

    Gosvig, K K; Jacobsen, S; Palm, H;

    2007-01-01

    Femoroacetabular cam impingement is thought to be a cause of premature osteoarthritis of the hip. The presence of cam malformation was determined in 2803 standardised anteroposterior (AP) pelvic radiographs from the Copenhagen Osteoarthritis Study by measuring the alpha (alpha) angle and the tria...

  17. Use of Complementary and Alternative Medicine (CAM) Treatments by Parents of Children with Autism Spectrum Disorders

    Science.gov (United States)

    Christon, Lillian M.; Mackintosh, Virginia H.; Myers, Barbara J.

    2010-01-01

    Parents of children with autism spectrum disorders (ASDs) may elect to use complementary and alternative medicine (CAM) treatments with their children in place of, or in addition to, conventional treatments. CAM treatments are controversial and understudied and, for most, the efficacy has not been established. The current study (n = 248) examined…

  18. A Methodological Framework for Evaluating the Evidence for Complementary and Alternative Medicine (CAM) for Cancer

    DEFF Research Database (Denmark)

    Zachariae, Robert; Johannessen, Helle

    2011-01-01

    In spite of lacking evidence for effects on cancer progression itself, an increasing number of cancer patients use various types of complementary and alternative medicine (CAM). There is disagreement between CAM practitioners, researchers and clinical oncologists, as to how evidence concerning...

  19. Some Aspects on Technological Design of a Cam Type Workpiece Using CATIA Software

    Directory of Open Access Journals (Sweden)

    Calin-Octavian Miclosina

    2013-09-01

    Full Text Available The paper presents the geometrical models of cam and of semi-finished piece, obtained with CATIA software. Two cam technological routes are shown and the optimal route is chosen. From the technological route, rough milling operation is simulated with CATIA software. By using different milling parameters, various machining time values are obtained.

  20. Bidirectional modulation of endogenous EpCAM expression to unravel its function in ovarian cancer

    NARCIS (Netherlands)

    van der Gun, B. T. F.; Huisman, C.; Stolzenburg, S.; Kazemier, H. G.; Ruiters, M. H. J.; Blancafort, P.; Rots, M. G.

    2013-01-01

    Background: The epithelial cell adhesion molecule (EpCAM) is overexpressed on most carcinomas. Dependent on the tumour type, its overexpression is either associated with improved or worse patient survival. For ovarian cancer, however, the role of EpCAM remains unclear. Methods: Cell survival of ovar

  1. A new radiological index for assessing asphericity of the femoral head in cam impingement

    DEFF Research Database (Denmark)

    Gosvig, K K; Jacobsen, S; Palm, H

    2007-01-01

    Femoroacetabular cam impingement is thought to be a cause of premature osteoarthritis of the hip. The presence of cam malformation was determined in 2803 standardised anteroposterior (AP) pelvic radiographs from the Copenhagen Osteoarthritis Study by measuring the alpha (alpha) angle and the tria...

  2. Numerical verification of similar Cam-clay model based on generalized potential theory

    Institute of Scientific and Technical Information of China (English)

    钟志辉; 杨光华; 傅旭东; 温勇; 张玉成

    2014-01-01

    From the mathematical principles, the generalized potential theory can be employed to create constitutive model of geomaterial directly. The similar Cam-clay model, which is created based on the generalized potential theory, has less assumptions, clearer mathematical basis, and better computational accuracy. Theoretically, it is more scientific than the traditional Cam-clay models. The particle flow code PFC3D was used to make numerical tests to verify the rationality and practicality of the similar Cam-clay model. The verification process was as follows: 1) creating the soil sample for numerical test in PFC3D, and then simulating the conventional triaxial compression test, isotropic compression test, and isotropic unloading test by PFC3D; 2) determining the parameters of the similar Cam-clay model from the results of above tests; 3) predicting the sample’s behavior in triaxial tests under different stress paths by the similar Cam-clay model, and comparing the predicting results with predictions by the Cam-clay model and the modified Cam-clay model. The analysis results show that the similar Cam-clay model has relatively high prediction accuracy, as well as good practical value.

  3. Transcription factors and molecular epigenetic marks underlying EpCAM overexpression in ovarian cancer

    NARCIS (Netherlands)

    van der Gun, B. T. F.; de Groote, M. L.; Kazemier, H. G.; Arendzen, A. J.; Terpstra, P.; Ruiters, M. H. J.; McLaughlin, P. M. J.; Rots, M. G.

    2011-01-01

    BACKGROUND: The epithelial cell adhesion molecule (EpCAM) is overexpressed on carcinomas, and its downregulation inhibits the oncogenic potential of multiple tumour types. Here, we investigated underlying mechanisms of epcam overexpression in ovarian carcinoma. METHODS: Expression of EpCAM and DNA m

  4. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    Science.gov (United States)

    Papadiochou, Sofia; Pissiotis, Argirios L

    2017-09-27

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  5. 基于CamShift的手势跟踪算法的定点实现%Fixed-Point Implementation of Gesture Tracking Algorithm Based on CamShift

    Institute of Scientific and Technical Information of China (English)

    廖凌宇

    2012-01-01

    在OpenCV 1.0中CamShift浮点算法的基础上,对算法进行定点实现。介绍CamShift算法的基本原理,详细阐述对CamShift浮点程序定点化的方案、流程和具体方法。定点化结果表明,定点化后程序与原浮点程序偏差较小。满足跟踪性能的要求.可用于下一步的硬件实现。%Describes the fixed-point implementation of CamShift algorithm based on OpenCV 1.0. Intro- duces the basic principles of the CamShift algorithm, and elaborates the float-point to fixed- point program and flow of CamShift algorithm. The result of experimentation shows that the de- viation between the float-point and fixed-point is small, can meet the requirement of tracking application, and can be used to the hardware implementation of next step.

  6. The C. elegans ROR receptor tyrosine kinase, CAM-1, non-autonomously inhibits the Wnt pathway.

    Science.gov (United States)

    Green, Jennifer L; Inoue, Takao; Sternberg, Paul W

    2007-11-01

    Inhibitors of Wnt signaling promote normal development and prevent cancer by restraining when and where the Wnt pathway is activated. ROR proteins, a class of Wnt-binding receptor tyrosine kinases, inhibit Wnt signaling by an unknown mechanism. To clarify how RORs inhibit the Wnt pathway, we examined the relationship between Wnts and the sole C. elegans ROR homolog, cam-1, during C. elegans vulval development, a Wnt-regulated process. We found that loss and overexpression of cam-1 causes reciprocal defects in Wnt-mediated cell-fate specification. Our molecular and genetic analyses revealed that the CAM-1 extracellular domain (ECD) is sufficient to non-autonomously antagonize multiple Wnts, suggesting that the CAM-1/ROR ECD sequesters Wnts. A sequestration model is supported by our findings that the CAM-1 ECD binds to several Wnts in vitro. These results demonstrate how ROR proteins help to refine the spatial pattern of Wnt activity in a complex multicellular environment.

  7. Optimal Design of a Cam Mechanism with Translating Flat-Face Follower using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    I. Tsiafis

    2013-12-01

    Full Text Available The optimum design of a cam mechanism is a time consuming task, due to the numerous alternatives considerations. In the present work, the problem of design parameters optimization of a cam mechanism with translating flat - face follower is investigated from a multi - objective point of view. The design parameters, just like the cam base circle radius, the follower face width and the follower offset can be determined considering as the optimization criteria minimization of the cam size, of the input torque and of the contact stress. During the optimization procedure, a number of constraints regarding the pressure angle, the contact stress, etcare taken into account. The optimization approach, based on genetic algorithm, is applied to find the optimal solutions with respect to the a fore - mentioned objective function and to Ensure the kinematic requirements. Finally, the dynamic behavior of the designed cam mechanism is investigated considering the frictional forces.

  8. Introduction to exploring opportunities for advancing collaborative adaptive management (CAM: integrating experience and practice

    Directory of Open Access Journals (Sweden)

    David L. Galat

    2014-06-01

    Full Text Available This Special Feature of Ecology and Society seeks to communicate a practitioner’s perspective on the application of collaborative adaptive management (CAM to contemporary natural resource management problems. One goal is to create an ongoing mechanism for dialogue that can connect practitioners, researchers, and policy makers. The core 15 papers are grouped into 3 categories that: (1 describe lessons learned through the practice of applying CAM principles to a specific project or generalizing principles from outcomes of a specific project; (2 summarize lessons learned from the author’s extensive CAM experiences; and (3 seek to be instructive of one or more CAM principles through a survey, evaluation, or comparison of multiple projects. Follow-up questions were submitted by authors to the online discussion section of Ecology and Society to stimulate interactive communication among readers and authors about their papers and CAM in general.

  9. Ceramic dental biomaterials and CAD/CAM technology: state of the art.

    Science.gov (United States)

    Li, Raymond Wai Kim; Chow, Tak Wah; Matinlinna, Jukka Pekka

    2014-10-01

    Ceramics are widely used as indirect restorative materials in dentistry because of their high biocompatibility and pleasing aesthetics. The objective is to review the state of the arts of CAD/CAM all-ceramic biomaterials. CAD/CAM all-ceramic biomaterials are highlighted and a subsequent literature search was conducted for the relevant subjects using PubMed followed by manual search. Developments in CAD/CAM technology have catalyzed researches in all-ceramic biomaterials and their applications. Feldspathic glass ceramic and glass infiltrated ceramic can be fabricated by traditional laboratory methods or CAD/CAM. The advent of polycrystalline ceramics is a direct result of CAD/CAM technology without which the fabrication would not have been possible. The clinical uses of these ceramics have met with variable clinical success. Multiple options are now available to the clinicians for the fabrication of aesthetic all ceramic restorations. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  10. Aplikace CAD/CAM softwaru FeatureCAM při obrábění

    OpenAIRE

    Foltán, Petr

    2013-01-01

    Diplomová práce obsahuje vypracovaný postup výroby části kokily pro gravitační lití pístů s využitím softwaru FeatureCAM. Zabývá se výběrem vhodného strojního a nástrojového vybavení, určením řezných podmínek a řešením výběru optimálních strategií obrábění v softwaru FeatureCAM. Celý proces obrábění je ověřen grafickou simulací a je doplněn výkresovou dokumentací součásti. The diploma thesis contains the manufacturing process of ingot mold part for pistons manufactured by gravity casting u...

  11. Survey of UK dentists regarding the use of CAD/CAM technology.

    Science.gov (United States)

    Tran, D; Nesbit, M; Petridis, H

    2016-11-18

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dentists' use and reporting of this technology.Purpose The purpose of this survey was to identify the infiltration of CAD/CAM technology in UK dental practices and to investigate the relationship of various demographic factors to the answers regarding use or non-use of this technology.Materials and methods One thousand and thirty-one online surveys were sent to a sample of UK dentists composing of both users and non-users of CAD/CAM. It aimed to reveal information regarding type of usage, materials, perceived benefits, barriers to access, and disadvantages of CAD/CAM dentistry. Statistical analysis was undertaken to test the influence of various demographic variables such as country of work, dentist experience, level of training and type of work (NHS or private).Results The number of completed responses totalled 385. Most of the respondents did not use any part of a digital workflow, and the main barriers to CAD/CAM use were initial costs and a lack of perceived benefit over conventional methods. Dentists delivering mostly private work were most likely to have adopted CAD/CAM technology (P CAD/CAM usage (P CAD/CAM had a big role to play in the future.Conclusion Most of the respondents did not use any part of a digital workflow. However, the majority of surveyed dentists were interested in incorporating CAD/CAM into their workflow, while most believed that it will have a big role in the future. There are still some concerns from dentists about the quality of chairside CAD/CAM restorations while the costs are still in the main hugely prohibitive (especially for NHS dentistry).

  12. CAM use in pediatric neurology: an exploration of concurrent use with conventional medicine.

    Directory of Open Access Journals (Sweden)

    Elaine Galicia-Connolly

    Full Text Available BACKGROUND: Previous studies have found that up to 60% of children with neurologic conditions have tried complementary and alternative medicine (CAM. OBJECTIVE: To assess the use of CAM among patients presenting to neurology clinics at two academic centers in Canada. METHODS: A survey instrument was developed to inquire about use of CAM products and therapies, including reasons for use, perceived helpfulness, and concurrent use with conventional medicine, and administered to patients or their parents/guardians at the Stollery Children's Hospital in Edmonton and the Children's Hospital of Eastern Ontario (CHEO in Ottawa. RESULTS: Overall CAM use at the Stollery was 78%, compared to 48% at CHEO. The most common CAM products used were multi-vitamins (84%, vitamin C (37%, homeopathic remedies (24%, and fish oil/omega 3 s (22%. The most common CAM practices used were massage (47%, chiropractic (37%, faith healing (18%, aromatherapy (16%, homeopathy (16%, and relaxation (16%. Many patients used CAM products at the same time as conventional medicine but just over half (57% discussed this concurrent use with their physician. CONCLUSION: CAM use is common in pediatric neurology patients and most respondents felt that it was helpful, with few or no harms associated. However, this use is often undisclosed, increasing possibility of interactions with conventional drugs. We urge clinicians to inquire about CAM use during routine history taking at every patient visit. Parents would clearly like more information about CAM from their specialty clinics; such information would be easier to share if more primary data were available about the safety and effectiveness of commonly used therapies.

  13. Prevalence and Predictors of Complementary and Alternative Medicine (CAM) Use among Ivy League College Students: Implications for Student Health Services

    Science.gov (United States)

    Versnik Nowak, Amy L.; DeGise, Joe; Daugherty, Amanda; O'Keefe, Richard; Seward, Samuel, Jr.; Setty, Suma; Tang, Fanny

    2015-01-01

    Objective: Determine prevalence and types of complementary and alternative medicine (CAM) therapies used and test the significance of demographics and social cognitive constructs as predictors of CAM use in a college sample. Secondary purpose was to guide the integration of CAM therapies into college health services. Participants: Random,…

  14. Social and Cultural Factors Affecting Complementary and Alternative Medicine (CAM Use during Menopause in Sydney and Bologna

    Directory of Open Access Journals (Sweden)

    Corinne van der Sluijs

    2013-01-01

    Full Text Available Background. Previous surveys found CAM use during menopause to be popular. This paper compares the results from two surveys (Sydney and Bologna to examine factors that determine the extent and pattern of CAM use to alleviate menopausal symptoms. Methods. Women, aged 45–65 years, who were symptomatic when transitioning through menopause or asymptomatic but taking menopause-specific treatments, were recruited in Sydney (n=1,296 and Bologna (n=1,106 to complete the same voluntary, anonymous, and self-administered questionnaire. The results were reanalysed using stratified analyses to determine similarities and differences. Results. Demographics of the two cohorts differed significantly. CAM was more popular in Sydney. The most significant determinants of CAM use were the use of CAM for other conditions besides menopause and the severity of vasomotor symptoms. Occupational status was a determinant of CAM use amongst Bologna respondents only. In order to relieve symptoms, Australian and Italian women used different CAM modalities whose effectiveness was generally perceived as good. Conclusion. CAM use is popular amongst menopausal women from Sydney and Bologna. Differences in the patterns of CAM use seem to depend on CAM availability and on the educational level and professional status of users. The complex interaction between market, social, and cultural factors of CAM use seems to be more influential on women’s choice of CAM than the available evidence of their effectiveness.

  15. Prevalence and Predictors of Complementary and Alternative Medicine (CAM) Use among Ivy League College Students: Implications for Student Health Services

    Science.gov (United States)

    Versnik Nowak, Amy L.; DeGise, Joe; Daugherty, Amanda; O'Keefe, Richard; Seward, Samuel, Jr.; Setty, Suma; Tang, Fanny

    2015-01-01

    Objective: Determine prevalence and types of complementary and alternative medicine (CAM) therapies used and test the significance of demographics and social cognitive constructs as predictors of CAM use in a college sample. Secondary purpose was to guide the integration of CAM therapies into college health services. Participants: Random,…

  16. EpCAM-selective elimination of carcinoma cells by a novel MAP-based cytolytic fusion protein

    NARCIS (Netherlands)

    Hristodorov, Dmitrij; Amoury, Manal; Mladenov, Radoslav; Niesen, Judith; Arens, Katharina; Berges, Nina; Hein, Lea; di Fiore, Stefano; Pham, Anh-Tuan; Huhn, Michael; Helfrich, Wijnand; Fischer, Rainer; Thepen, Theo; Barth, Stefan

    2014-01-01

    In normal epithelia, the epithelial cell adhesion molecule (EpCAM) expression is relatively low and only present at the basolateral cell surface. In contrast, EpCAM is aberrantly overexpressed in various human carcinomas. Therefore, EpCAM is considered to be a highly promising target for antibody-ba

  17. Failure strengths of repair devices versus meniscus suturing techniques

    OpenAIRE

    Asik, Mehmet; Sener, Nadir; Dikici, Fatih; Sen, Cengiz

    2004-01-01

    Objectives: The purpose of this study was to compare the load to failure of different common suturing techniques with that of repair devices. Methods: Seventy-one calf medial menisci were cut to simulate peripheral longitudinal tears and repaired using either one of the two suture techniques or one of the seven repair devices. Then the two parts of the meniscus were pulled using an Instron tensometer until failure occurred. The techniques and repair devices tested included vertical (0 PDS,...

  18. Understanding dental CAD/CAM for restorations - dental milling machines from a mechanical engineering viewpoint. Part A: chairside milling machines.

    Science.gov (United States)

    Lebon, Nicolas; Tapie, Laurent; Duret, Francois; Attal, Jean-Pierre

    2016-01-01

    The dental milling machine is an important device in the dental CAD/CAM chain. Nowadays, dental numerical controlled (NC) milling machines are available for dental surgeries (chairside solution). This article provides a mechanical engineering approach to NC milling machines to help dentists understand the involvement of technology in digital dentistry practice. First, some technical concepts and definitions associated with NC milling machines are described from a mechanical engineering viewpoint. The technical and economic criteria of four chairside dental NC milling machines that are available on the market are then described. The technical criteria are focused on the capacities of the embedded technologies of these milling machines to mill both prosthetic materials and types of shape restorations. The economic criteria are focused on investment costs and interoperability with third-party software. The clinical relevance of the technology is assessed in terms of the accuracy and integrity of the restoration.

  19. Using CAD/CAM to improve productivity - The IPAD approach

    Science.gov (United States)

    Fulton, R. E.

    1981-01-01

    Progress in designing and implementing CAD/CAM systems as a result of the NASA Integrated Programs for Aerospace-Vehicle Design is discussed. Essential software packages have been identified as executive, data management, general user, and geometry and graphics software. Data communication, as a means to integrate data over a network of computers of different vendors, provides data management with the capability of meeting design and manufacturing requirements of the vendors. Geometry software is dependent on developmental success with solid geometry software, which is necessary for continual measurements of, for example, a block of metal while it is being machined. Applications in the aerospace industry, such as for design, analysis, tooling, testing, quality control, etc., are outlined.

  20. Chemical composition of umbu (Spondias tuberosa Arr. Cam seeds

    Directory of Open Access Journals (Sweden)

    Soraia Vilela Borges

    2007-02-01

    Full Text Available The umbu tree (Spondias tuberosa Arr. Cam is an important fruit tree the economy of the semi-arid northeastern region of Brazil. With the objective of finding use for the seeds, physical and chemical characterizations of the seeds from 2 cultivars in 2 maturation stages were carried out and their fatty acid and mineral profiles determined. The results showed no differences between the seeds analyzed. The yield was about 10% and the dimensions as follows: length from 1.48 to 2.11 cm and width from 0.76 to 1.16 cm. The average lipid content was 55% of which 69% was unsaturated and the average protein content was 24%. The seeds were a good source of the following minerals: P, K, Mg, Fe and Cu. The overall results indicated that the oil or the seeds could be used for food stuffs if no toxic agents were found.

  1. Innovative Design of Cam-Controlled Planetary Gear Trains

    Directory of Open Access Journals (Sweden)

    Wen-Hsiang Hsieh

    2011-10-01

    Full Text Available The objective of this paper is to perform the innovation design for the new structures of cam-controlled planetary gear trains (CCPGTs, based on the creative mechanism design methodology. Firstly, the design requirements and design constraints are summarized according to the kinematics characteristics of existing CCPGTs. Then, the (4, 5 and (5, 7 graphs are generated by the theory of number synthesis. After that, the atlas of feasible specialized graphs is obtained. Finally, the atlas of new designs is obtained through the particularization process. In addition, an illustrated example is given, and the feasibility of the design is verified by computer simulation using ADAMS software. The result indicates that new design can produce a more wide range of non-uniform motion than the existing design. Therefore, they are better alternatives for driving a variable speed input mechanism.

  2. Lacie phase 1 Classification and Mensuration Subsystem (CAMS) rework experiment

    Science.gov (United States)

    Chhikara, R. S.; Hsu, E. M.; Liszcz, C. J.

    1976-01-01

    An experiment was designed to test the ability of the Classification and Mensuration Subsystem rework operations to improve wheat proportion estimates for segments that had been processed previously. Sites selected for the experiment included three in Kansas and three in Texas, with the remaining five distributed in Montana and North and South Dakota. The acquisition dates were selected to be representative of imagery available in actual operations. No more than one acquisition per biophase were used, and biophases were determined by actual crop calendars. All sites were worked by each of four Analyst-Interpreter/Data Processing Analyst Teams who reviewed the initial processing of each segment and accepted or reworked it for an estimate of the proportion of small grains in the segment. Classification results, acquisitions and classification errors and performance results between CAMS regular and ITS rework are tabulated.

  3. Building a Sectional Aerosol Model in CAM5

    Science.gov (United States)

    Yu, P.; Toon, O. B.

    2013-12-01

    Aerosols are widely distributed around the globe. In the current study I use a sectional aerosol microphysics model (CARMA) coupled with the NCAR global climate model, CAM5, to simulate the spatial-temporal distribution of various types of aerosols including organics, black carbon, sulfate, sea salt and dust. Organics and black carbon surface concentrations are simulated within ~50% over the U.S, and Europe compared with observations; the amount of modeled sulfate and organics are equal in UTLS region as observed by the Pre-AVE field campaign; aerosol extinction in the UTLS observed by SAGEII can be explained by secondary organic aerosols combined with sulfate aerosol. For treating secondary organic aerosols, the volatility-basis-set method improves the budget at surface level relative to the traditional two-product partitioning method; black carbon global budget is largely improved especially in high latitudes by introducing new emission database.

  4. Photon counting phosphorescence lifetime imaging with TimepixCam

    Science.gov (United States)

    Hirvonen, Liisa M.; Fisher-Levine, Merlin; Suhling, Klaus; Nomerotski, Andrei

    2017-01-01

    TimepixCam is a novel fast optical imager based on an optimized silicon pixel sensor with a thin entrance window and read out by a Timepix Application Specific Integrated Circuit. The 256 × 256 pixel sensor has a time resolution of 15 ns at a sustained frame rate of 10 Hz. We used this sensor in combination with an image intensifier for wide-field time-correlated single photon counting imaging. We have characterised the photon detection capabilities of this detector system and employed it on a wide-field epifluorescence microscope to map phosphorescence decays of various iridium complexes with lifetimes of about 1 μs in 200 μm diameter polystyrene beads.

  5. The electronic counting arm movement test (eCAM test).

    Science.gov (United States)

    Bodranghien, Florian; Martin, Claire; Ansay, Caroline; Camut, Stephane; Busegnies, Yves; Manto, Mario

    2015-06-01

    A novel transportable electronic platform aiming to characterize the performance of successive fast vertical visually guided pointing movements toward two fixed targets (eCAM test: electronic counting arm movement test) is described and one validation test is presented. This platform is based on an Arduino(®) micro-controller and a Processing(®) routine. It records both the pointing performance (number of clicks) and the elapsed time between two successive pointing movements. Using this novel platform, we studied the effects of functional electrical stimulation (FES) applied on the dominant upper limb in 15 healthy volunteers (mean age ± SD: 22.3 ± 4.3 years; 5 males/10 females). The following muscles were stimulated: flexor carpi radialis (FCR), extensor carpi radialis (ECR), biceps brachii (BB), and triceps brachii (TB). The intensities of the stimulation were 2 and 3 mA above the sensory threshold (ST). Movement times were lesser when performed against gravity and pointing performance improved with FES. We provide the first demonstration that low-intensity FES impacts on motor performances during successive vertical goal-directed pointing movements under visual guidance. The eCAM test is currently the sole electronic tool to assess quickly and easily the performances of successive vertical pointing movements. Future potential applications include, in particular, the follow-up of the effects of neurorehabilitation of neurological/neurosurgical disorders associated with hand-eye incoordination, the functional evaluation of upper limb prosthesis or orthosis, and the analysis of the effects of FES in central or peripheral nervous system disorders.

  6. Hydrogen detection with ChemCam at Gale crater

    Science.gov (United States)

    Schröder, S.; Meslin, P.-Y.; Gasnault, O.; Maurice, S.; Cousin, A.; Wiens, R. C.; Rapin, W.; Dyar, M. D.; Mangold, N.; Forni, O.; Nachon, M.; Clegg, S.; Johnson, J. R.; Lasue, J.; Le Mouélic, S.; Ollila, A.; Pinet, P.; Sautter, V.; Vaniman, D.

    2015-03-01

    One of the main advantages of ChemCam's LIBS (Laser-Induced Breakdown Spectroscopy) instrument onboard the Curiosity rover is its potential to detect light elements such as hydrogen at fine scales, which has never been achieved on Mars. Hydrogen lines are detected in most of the data obtained within the first 320 sols of the mission at Gale crater, Mars. This work is a description of the hydrogen signal and its variability in the ChemCam LIBS spectra; it discusses the challenges of qualitative and quantitative analysis. Data acquisition and processing steps are investigated and optimized for the detection of hydrogen on Mars. Subtraction of an appropriate dark spectrum and the deconvolution of the superimposed emission of carbon from the low-pressure CO2-dominated atmosphere are particularly important. Because the intensities of hydrogen are also affected by matrix effects, the hydrogen signal was investigated within groups of targets sharing common chemical features and similar matrices. The different groups cover a variety of rock and soil compositions encountered along the traverse (calcium sulfate veins, mafic soils, felsic, Mg-rich and Fe-rich rocks) including data from both drill holes and their tailings. Almost all these targets were found to be hydrated to variable extents. Soils have systematically higher hydrogen signals than rocks and pebbles, probably as a result of their alteration. The results from rocks suggest that various alteration processes leading to their hydration have taken place, which is consistent with the fluvial lacustrine context, the diagenetic features, and the mineralogy observed by Curiosity in Yellowknife Bay.

  7. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  8. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma

    Directory of Open Access Journals (Sweden)

    Raj V Azad

    2014-01-01

    Full Text Available Purpose: To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Design: Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. Materials and Methods: A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible and details of angle structures seen were graded for both methods, on digitally recorded images, in each eye, by two masked observers. Outcome Measures: Image clarity, interobserver agreement. Results: 40 eyes of 25 congenital glaucoma patients were studied. RetCam image had excellent clarity in 77.5% of patients versus 47.5% by gonioscopy. The extent of angle seen was similar by both methods. Agreement between RetCam and gonioscopy images regarding details of angle structures was 72.50% by observer 1 and 65.00% by observer 2. Conclusions: There was good agreement between RetCam and indirect gonioscopy images in detecting angle structures of congenital glaucoma patients. However, RetCam provided greater clarity, with better quality, and higher magnification images. RetCam can be a useful alternative to gonioscopy in infants and small children without the need for general anesthesia.

  9. COMPLEMENTARY AND ALTERNATIVE MEDICINE (CAM THERAPIES FOR MANAGEMENT OF PAIN RELATED TO ENDOMETRIOSIS

    Directory of Open Access Journals (Sweden)

    Panda Roshni

    2012-03-01

    Full Text Available Endometriosis is a gynaecological disease with a complex etiology. It is associated with severe pelvic pain, sub fertility and reduced quality of life. Endometriosis has a multifactorial etiology and therefore its management is also multidimensional. The main targets of therapy are controlling of the pain symptoms and increasing fertility where it is desired. Hormonal and surgical therapies are the two major treatment modalities available currently. But they are not without their side effects. Therefore many women explore Complementary and Alternative Medicine (CAM forms of treatment for symptomatic relief from pain. These CAM therapies have been used as an adjuvant to conventional therapy or as an independent form of treatment. CAM therapies are purported to have lesser side effects as compared to conventional medical formulations. Ancient Chinese and Indian medicine system have laid the foundation of several of the prevalent Cam practices. The following CAM practices have been discussed in the article-Acupuncture, Herbal therapy, Meditation and Hypnotherapy, Yoga, Exercise, Dietary therapy Aromatherapy and Massage, Reiki, Magnet therapy and Chiropractice. Randomized Clinical Trials (RCT have been conducted for some of the CAM therapies in Endometriosis and Acupuncture and Herbal and Dietary therapies have been found to have some positive effect on the patients. The efficacy of CAM therapies still needs substantial evidence to be integrated into general healthcare practices.

  10. Discrimination in health care and CAM use in a representative sample of U.S. adults.

    Science.gov (United States)

    Thorburn, Sheryl; Faith, Jennifer; Keon, Karen Levy; Tippens, Kimberly M

    2013-06-01

    Discrimination in medical settings may influence patient attitudes about health care and health-seeking behaviors. Patients who experience discrimination may seek alternative means of health care, including use of complementary and alternative medicine (CAM). The objective of this study was to examine the relationship between discrimination in health care and CAM use. Data come from the 2001 Health Care Quality Survey (HCQS), which used a multistage sampling design with random-digit dialing, oversampling telephone exchanges with higher densities of African-American, Hispanic, and Asian households. The 2001 HCQS sample consisted of 6722 adults living in the continental United States. To correct for the disproportionate sample design, data were adjusted using sample weights to make the results representative of the U.S. population 18 years and older. Present analyses were limited to 6008 respondents who had visited a doctor or clinic or had been admitted to the hospital in the last 2 years. Outcome measures were CAM use, practitioner-provided CAM use, and herbal medicine use. In adjusted logistic regression analyses, discrimination in health care was significantly associated with use of herbal medicines alone (adjusted odds ratio=1.47, confidence interval: 1.05, 2.04), but not with use of practitioner-provided CAM (i.e., use of acupuncture, chiropractor, traditional healer or herbalist, alone or in combination with herbal medicines). Further research is needed to examine the direction of the relationship between discrimination and CAM use and differences by CAM modality.

  11. The CAM Education Program of the National Center for Complementary and Alternative Medicine: an overview.

    Science.gov (United States)

    Pearson, Nancy J; Chesney, Margaret A

    2007-10-01

    The authors provide a historical context and overview of the experience of education projects at 14 health professions schools in the United States and the American Medical Students Association that were funded by the National Center for Complementary and Alternative Medicine at the National Institutes of Health in cohorts of five per year in 2000, 2001, and 2002-2003. These 15 projects were designed to incorporate CAM information into the curricula of conventional health professions schools. A longer-term goal was to accelerate the integration of CAM and conventional medicine. The overall program started in 2000 at a time when discussions about the definition, goals, and value of integrative medicine were already well underway. The efforts specific to each project, as well as the shared challenges, accomplishments, and collaborative efforts of all 15 projects, can provide guidance for the education of conventional health care providers about CAM in an integrative medicine environment. Challenging issues that must be faced include (1) the need to develop successful strategies to incorporate information about CAM into already dense health professions school curricula, (2) the need for conventional health professionals to have authoritative resources to provide their patients information about risks and benefits of CAM practices, and (3) the need to identify appropriate roles for CAM practitioners in educating conventional health professionals about CAM therapies. The authors discuss these issues and others and present some recommendations.

  12. Modeling analysis of the benefits of Crassulacean acid metabolism (CAM) for sustainable agriculture in arid regions

    Science.gov (United States)

    Bartlett, M. S.; Vico, G.; Porporato, A. M.

    2012-12-01

    In view of the pressing needs to sustainably manage water and soil resources, especially in arid and semi-arid regions, here we propose a new carbon assimilation model that couples a simple yet mechanistic description of Crassulacean acid metabolism (CAM) photosynthesis to the soil-plant-atmosphere continuum. The model captures the full coupling of the CAM photosynthetic pathway with fluctuations in environmental conditions (cycles of light availability and air humidity, changes in soil moisture as driven by plant transpiration and rainfall occurrence). As such, the model is capable of reproducing the different phases of CAM, including daytime stomatal closure and photosynthesis from malic acid, afternoon stomatal opening for direct carbon assimilation, and nighttime stomatal opening for CO2 uptake and malic acid synthesis. Thanks to its versatility, our model allows us to relate CAM productivity, for both obligate and facultative CAM plants, to various soil moisture conditions including hydroclimatic scenarios of rainfall frequency and intensity as well as different night-time conditions of temperature, wind speed, and humidity. Our analyses show the potential productive benefits of CAM cultivation in dryland environments as feedstock and possible biofuel source, in terms of sustainable water use and economic benefits. In particular, the model is used to explore conditions where CAM plant resiliency to water stress makes these plants a more sustainable alternative to C3 and C4 species for potential deficit irrigation.

  13. The In Ovo Chick Chorioallantoic Membrane (CAM) Assay as an Efficient Xenograft Model of Hepatocellular Carcinoma.

    Science.gov (United States)

    Li, Michael; Pathak, Ravi R; Lopez-Rivera, Esther; Friedman, Scott L; Aguirre-Ghiso, Julio A; Sikora, Andrew G

    2015-10-09

    The chick chorioallantoic membrane (CAM) begins to develop by day 7 after fertilization and matures by day 12. The CAM is naturally immunodeficient and highly vascularized, making it an ideal system for tumor implantation. Furthermore, the CAM contains extracellular matrix proteins such as fibronectin, laminin, collagen, integrin alpha(v)beta3, and MMP-2, making it an attractive model to study tumor invasion and metastasis. Scientists have long taken advantage of the physiology of the CAM by using it as a model of angiogenesis. More recently, the CAM assay has been modified to work as an in vivo xenograft model system for various cancers that bridges the gap between basic in vitro work and more complex animal cancer models. The CAM assay allows for the study of tumor growth, anti-tumor therapies, and pro-tumor molecular pathways in a biologically relevant system that is both cost- and time-effective. Here, we describe the development of CAM xenograft model of hepatocellular carcinoma (HCC) with embryonic survival rates of up to 93% and reliable tumor take leading to growth of three-dimensional, vascularized tumors.

  14. CAM therapies among primary care patients using opioid therapy for chronic pain

    Directory of Open Access Journals (Sweden)

    Mundt Marlon P

    2007-05-01

    Full Text Available Abstract Background Complementary and alternative medicine (CAM is an increasingly common therapy used to treat chronic pain syndromes. However; there is limited information on the utilization and efficacy of CAM therapy in primary care patients receiving long-term opioid therapy. Method A survey of CAM therapy was conducted with a systematic sample of 908 primary care patients receiving opioids as a primary treatment method for chronic pain. Subjects completed a questionnaire designed to assess utilization, efficacy and costs of CAM therapies in this population. Results Patients were treated for a variety of pain problems including low back pain (38.4%, headaches (9.9%, and knee pain (6.5%; the average duration of pain was 16 years. The median morphine equivalent opioid dose was 41 mg/day, and the mean dose was 92 mg/day. Forty-four percent of the sample reported CAM therapy use in the past 12 months. Therapies utilized included massage therapy (27.3%, n = 248, chiropractic treatment (17.8%, n = 162, acupuncture (7.6%, n = 69, yoga (6.1%, n = 55, herbs and supplements (6.8%, n = 62, and prolotherapy (5.9%, n = 54. CAM utilization was significantly related to age female gender, pain severity income pain diagnosis of neck and upper back pain, and illicit drug use. Medical insurance covered chiropractic treatment (81.8% and prolotherapy (87.7%, whereas patients primarily paid for other CAM therapies. Over half the sample reported that one or more of the CAM therapies were helpful. Conclusion This study suggests CAM therapy is widely used by patients receiving opioids for chronic pain. Whether opioids can be reduced by introducing such therapies remains to be studied.

  15. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites.

    Science.gov (United States)

    Stawarczyk, Bogna; Liebermann, Anja; Eichberger, Marlis; Güth, Jan-Frederik

    2015-03-01

    To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50N, 5°/55°C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffé post-hoc test, Kruskal-Wallis-H test, and linear mixed models (α=0.05). IPS e.max CAD showed the highest FS (pCAD/CAM composites (exception: Shofu Block). The lowest FS showed VITA Enamic and IPS Empress CAD (pCAD, VITA Enamic, exp. CAD/CAM composite 2, followed by IPS e.max presented lower material TBW than the remaining CAD/CAM materials (pcurry>cress>distilled water) exerted the highest influence on DR (pCAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (pCAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Regulated intramembrane proteolysis and degradation of murine epithelial cell adhesion molecule mEpCAM.

    Directory of Open Access Journals (Sweden)

    Matthias Hachmeister

    Full Text Available Epithelial cell adhesion molecule EpCAM is a transmembrane glycoprotein, which is highly and frequently expressed in carcinomas and (cancer-stem cells, and which plays an important role in the regulation of stem cell pluripotency. We show here that murine EpCAM (mEpCAM is subject to regulated intramembrane proteolysis in various cells including embryonic stem cells and teratocarcinomas. As shown with ectopically expressed EpCAM variants, cleavages occur at α-, β-, γ-, and ε-sites to generate soluble ectodomains, soluble Aβ-like-, and intracellular fragments termed mEpEX, mEp-β, and mEpICD, respectively. Proteolytic sites in the extracellular part of mEpCAM were mapped using mass spectrometry and represent cleavages at the α- and β-sites by metalloproteases and the b-secretase BACE1, respectively. Resulting C-terminal fragments (CTF are further processed to soluble Aβ-like fragments mEp-β and cytoplasmic mEpICD variants by the g-secretase complex. Noteworthy, cytoplasmic mEpICD fragments were subject to efficient degradation in a proteasome-dependent manner. In addition the γ-secretase complex dependent cleavage of EpCAM CTF liberates different EpICDs with different stabilities towards proteasomal degradation. Generation of CTF and EpICD fragments and the degradation of hEpICD via the proteasome were similarly demonstrated for the human EpCAM ortholog. Additional EpCAM orthologs have been unequivocally identified in silico in 52 species. Sequence comparisons across species disclosed highest homology of BACE1 cleavage sites and in presenilin-dependent γ-cleavage sites, whereas strongest heterogeneity was observed in metalloprotease cleavage sites. In summary, EpCAM is a highly conserved protein present in fishes, amphibians, reptiles, birds, marsupials, and placental mammals, and is subject to shedding, γ-secretase-dependent regulated intramembrane proteolysis, and proteasome-mediated degradation.

  17. Forensic devices for activism: Metadata tracking and public proof

    Directory of Open Access Journals (Sweden)

    Lonneke van der Velden

    2015-10-01

    Full Text Available The central topic of this paper is a mobile phone application, ‘InformaCam’, which turns metadata from a surveillance risk into a method for the production of public proof. InformaCam allows one to manage and delete metadata from images and videos in order to diminish surveillance risks related to online tracking. Furthermore, it structures and stores the metadata in such a way that the documentary material becomes better accommodated to evidentiary settings, if needed. In this paper I propose InformaCam should be interpreted as a ‘forensic device’. By using the conceptualization of forensics and work on socio-technical devices the paper discusses how InformaCam, through a range of interventions, rearranges metadata into a technology of evidence. InformaCam explicitly recognizes mobile phones as context aware, uses their sensors, and structures metadata in order to facilitate data analysis after images are captured. Through these modifications it invents a form of ‘sensory data forensics'. By treating data in this particular way, surveillance resistance does more than seeking awareness. It becomes engaged with investigatory practices. Considering the extent by which states conduct metadata surveillance, the project can be seen as a timely response to the unequal distribution of power over data.

  18. Forensic devices for activism: Metadata tracking and public proof

    Directory of Open Access Journals (Sweden)

    Lonneke van der Velden

    2015-10-01

    Full Text Available The central topic of this paper is a mobile phone application, ‘InformaCam’, which turns metadata from a surveillance risk into a method for the production of public proof. InformaCam allows one to manage and delete metadata from images and videos in order to diminish surveillance risks related to online tracking. Furthermore, it structures and stores the metadata in such a way that the documentary material becomes better accommodated to evidentiary settings, if needed. In this paper I propose InformaCam should be interpreted as a ‘forensic device’. By using the conceptualization of forensics and work on socio-technical devices the paper discusses how InformaCam, through a range of interventions, rearranges metadata into a technology of evidence. InformaCam explicitly recognizes mobile phones as context aware, uses their sensors, and structures metadata in order to facilitate data analysis after images are captured. Through these modifications it invents a form of ‘sensory data forensics'. By treating data in this particular way, surveillance resistance does more than seeking awareness. It becomes engaged with investigatory practices. Considering the extent by which states conduct metadata surveillance, the project can be seen as a timely response to the unequal distribution of power over data.

  19. Strength of CAD/CAM-generated esthetic ceramic molar implant crowns

    OpenAIRE

    D. Wolf; Bindl, A; Schmidlin, P.R; Lüthy, H; Mörmann, W H

    2008-01-01

    PURPOSE: One-visit in-office CAD/CAM fabrication of esthetic ceramic crowns as a superstructure for posterior implants is quite new. The aim of the study was to evaluate the strength of esthetic ceramic CAD/CAM crowns with varied occlusal thickness and seated with adhesive and nonadhesive cements on titanium and zirconia abutments. MATERIALS AND METHODS: Esthetic ceramic CAD/CAM-generated molar crowns (n = 15 per group) with occlusal thicknesses of 0.5 mm and 1.5 mm were seated on titanium (1...

  20. Spatial data software integration - Merging CAD/CAM/mapping with GIS and image processing

    Science.gov (United States)

    Logan, Thomas L.; Bryant, Nevin A.

    1987-01-01

    The integration of CAD/CAM/mapping with image processing using geographic information systems (GISs) as the interface is examined. Particular emphasis is given to the development of software interfaces between JPL's Video Image Communication and Retrieval (VICAR)/Imaged Based Information System (IBIS) raster-based GIS and the CAD/CAM/mapping system. The design and functions of the VICAR and IBIS are described. Vector data capture and editing are studied. Various software programs for interfacing between the VICAR/IBIS and CAD/CAM/mapping are presented and analyzed.

  1. Aesthetic treatment option for completely edentulous patients using CAD/CAM technology.

    Science.gov (United States)

    Kleinman, Alejandro; Avendano, Sergio; Leyva, Francisco

    2008-04-01

    In recent years, advancements have been made in CAD/CAM technology that have allowed for the development of different treatments regarding the rehabilitation of patients with natural dentition, as well as patients with dental implants. Contemporary systems can also allow prosthetic rehabilitation for partially and completely edentulous patients. This article describes a restorative alternative to fixed implant-supported reconstruction of completely edentulous patients, utilizing a CAD/CAM-generated framework and CAD/CAM-generated all-ceramic cement-retained crowns. In addition to delivering an optimally aesthetic restoration, this design permits a precise and passive prosthetic fit.

  2. Digital data management for CAD/CAM technology. An update of current systems.

    Science.gov (United States)

    Andreiotelli, M; Kamposiora, P; Papavasiliou, G

    2013-03-01

    Abstract - Computer-aided design/computer-aided manufacturing (CAD/CAM) technology continues to rapidly evolve in the dental community. This review article provides an overview of the operational components and methodologies used with some of the CAD/CAM systems. Future trends are also discussed. While these systems show great promise, the quality of performance varies among systems. No single system currently acquires data directly in the oral cavity and produces restorations using all materials available. Further refinements of these CAD/CAM technologies may increase their capabilities, but further special training will be required for effective use.

  3. Conservative restorative treatment using a single-visit, all-ceramic CAD/CAM system.

    Science.gov (United States)

    Benk, Joel

    2007-01-01

    Computer-aided design/computer-aided manufacturing (CAD/CAM) continues to radically change the way in which the dental team plans, prepares, and fabricates a patient's restoration. This advancing technology offers the clinician the ability to scan the patient's failing dentition and then designs a long-lasting, reliable restoration based on this data. CAD/CAM systems also permit efficient, single-visit placement of the restoration while preserving much of the natural tooth structure. This article discusses how a chairside CAD/CAM system can be used to provide such a restoration in the posterior region in a single-visit.

  4. Aesthetic quadrant dentistry using a chairside CAD/CAM system: a case presentation.

    Science.gov (United States)

    Klim, James

    2006-04-01

    There are numerous CAD/CAM technologies available today for the production of highly aesthetic restorations with strength and precision. Laboratory-based CAD/CAM systems typically require the patient to receive a provisional restoration and then return to the dental office for a second visit for placement of the definitive restoration upon receipt from the laboratory. Chairside systems, as described in the following case presentation, allow excellent benefits to be achieved in one patient visit. Thus, this case presentation describes the sequences associated with single-visit, in-office CAD/CAM quadrant dentistry.

  5. Electronic cam motion generation with special reference to constrained velocity, acceleration, and jerk.

    Science.gov (United States)

    Liao, Chung-Shu; Jeng, Shyr-Long; Chieng, Wei-Hua

    2004-07-01

    Electronic cam motion involves velocity tracking control of the master motor and trajectory generation of the slave motor. Special concerns such as the limits of the velocity, acceleration, and jerk are beyond the considerations in the conventional electronic cam motion control. This study proposes the curve-fitting of a Lagrange polynomial to the cam profile, based on trajectory optimization by cubic B-spline interpolation. The proposed algorithms may yield a higher tracking precision than the conventional master-slaves control method does, providing an optimization problem is concerned. The optimization problem contains three dynamic constraints including velocity, acceleration, and jerk of the motor system.

  6. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials

    OpenAIRE

    2016-01-01

    PURPOSE: To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. MATERIALS AND METHODS: Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC ...

  7. Computer-assisted myelography (CAM) in the diagnosis of cervical disk disease. Correlation with surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Kotwica, Z.; Kasprzak, P. (Medical Univ. of Lodz, Dept. of Neurosurgery (Poland)); Chmielowski, M. (Medical Univ. of Lodz, School of Medicine, Dept. of Medical Imaging (Poland))

    A comparison was made between results obtained from preoperative computer-assisted myelography (CAM), on the one hand, and surgical findings, on the other, for 45 patients with suspicion of cervical disk disease. Full and correct diagnosis, subsequently confirmed by surgery, was enabled by CAM in 98% of all cases. Only one case was left in which preoperative diagnosis had been extraspinal tumour, while surgery revealed prolapse of the nucleus pulposus, the latter lying exposed on the anterior wall of the dural sac. The authors feel CAM to be sufficient for planning of surgical treatment for cervical disk desease, with other neuroradiological investigations, myelography or magnetic resonance tomography usually not being necessary. (orig.).

  8. Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

    OpenAIRE

    Kwon, Taek-Ka; Pak, Hyun-Soon; Yang, Jae-Ho; Han, Jung-Suk; Lee, Jai-Bong; Kim, Sung-Hun; Yeo, In-Sung

    2013-01-01

    PURPOSE All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also ...

  9. CAM operated tool for proximate or remote holding of an object

    Energy Technology Data Exchange (ETDEWEB)

    Schrum, P.B.; Gajdzik, G.P. Jr.

    1995-12-31

    A tool for releasably holding an object includes a receptacle having an outer sleeve and a rotatable inner sleeve. The inner sleeve is coaxially positioned within the outer sleeve and includes a locking member. An insert which is adapted to be operably associated with the receptacle includes a cam. The cam includes a guide and a slot so that when the cam is inserted into the inner sleeve, the guide aligns the locking member with the slot allowing the locking member to engage the slot thereby holding the receptacle and the insert together.

  10. Magnetic gripper device

    Science.gov (United States)

    Meyer, Ross E.

    1993-01-01

    A climbing apparatus is provided for climbing ferromagnetic surfaces, such as storage tanks and steel frame structures. A magnet assembly is rotatably mounted in a frame assembly. The frame assembly provides a pair of cam surfaces having different dimensions so that, when the frame is rotated, the cam surfaces contact the ferromagnetic surface to separate the magnet assembly from the surface. The different cam dimensions enable one side of the magnet at a time to be detached from the surface to reduce the effort needed to disengage the climbing apparatus. The cam surface also provides for smoothly attaching the apparatus. A hardened dowel pin is also attached to the frame and the pointed end of the dowel engages the surface when the magnet is attached to the surface to prevent downward sliding movement of the assembly under the weight of the user.

  11. Use of two-part regression calibration model to correct for measurement error in episodically consumed foods in a single-replicate study design: EPIC case study.

    Directory of Open Access Journals (Sweden)

    George O Agogo

    Full Text Available In epidemiologic studies, measurement error in dietary variables often attenuates association between dietary intake and disease occurrence. To adjust for the attenuation caused by error in dietary intake, regression calibration is commonly used. To apply regression calibration, unbiased reference measurements are required. Short-term reference measurements for foods that are not consumed daily contain excess zeroes that pose challenges in the calibration model. We adapted two-part regression calibration model, initially developed for multiple replicates of reference measurements per individual to a single-replicate setting. We showed how to handle excess zero reference measurements by two-step modeling approach, how to explore heteroscedasticity in the consumed amount with variance-mean graph, how to explore nonlinearity with the generalized additive modeling (GAM and the empirical logit approaches, and how to select covariates in the calibration model. The performance of two-part calibration model was compared with the one-part counterpart. We used vegetable intake and mortality data from European Prospective Investigation on Cancer and Nutrition (EPIC study. In the EPIC, reference measurements were taken with 24-hour recalls. For each of the three vegetable subgroups assessed separately, correcting for error with an appropriately specified two-part calibration model resulted in about three fold increase in the strength of association with all-cause mortality, as measured by the log hazard ratio. Further found is that the standard way of including covariates in the calibration model can lead to over fitting the two-part calibration model. Moreover, the extent of adjusting for error is influenced by the number and forms of covariates in the calibration model. For episodically consumed foods, we advise researchers to pay special attention to response distribution, nonlinearity, and covariate inclusion in specifying the calibration model.

  12. Research on Estimates of Xi’an City Life Garbage Pay-As-You-Throw Based on Two-part Tariff method

    Science.gov (United States)

    Yaobo, Shi; Xinxin, Zhao; Fuli, Zheng

    2017-05-01

    Domestic waste whose pricing can’t be separated from the pricing of public economics category is quasi public goods. Based on Two-part Tariff method on urban public utilities, this paper designs the pricing model in order to match the charging method and estimates the standard of pay-as-you-throw using data of the past five years in Xi’an. Finally, this paper summarizes the main results and proposes corresponding policy recommendations.

  13. IFEMS, an Interactive Finite Element Modeling System Using a CAD/CAM System

    Science.gov (United States)

    Mckellip, S.; Schuman, T.; Lauer, S.

    1980-01-01

    A method of coupling a CAD/CAM system with a general purpose finite element mesh generator is described. The three computer programs which make up the interactive finite element graphics system are discussed.

  14. First Fluorine and Chlorine Detections on Mars with ChemCam On-Board MSL

    Science.gov (United States)

    Forni, O.; Gaft, M.; Toplis, M.; Clegg, S. M.; Maurice, S.; Wiens, R. C.; Mangold, N.; Sautter, V.; Gasnault, O.; Berger, G.; Nachon, M.; Meslin, P.-Y.; Blaney, D.; Cousin, A.

    2014-07-01

    We report the first detection of fluorine on Mars and the first detection of chlorine with ChemCam onboard MSL/Curiosity. We discuss the plausible mineralogies for these two halogens and their possible origin.

  15. O-Cam: a new paradigm for investigating the effects of ostracism.

    Science.gov (United States)

    Goodacre, Rani; Zadro, Lisa

    2010-08-01

    A new ostracism paradigm-O-Cam-was designed to combine the best qualities of both social ostracism (i.e., face-to-face interaction between the target and sources of ostracism) and cyber ostracism (i.e., confederate-free, highly controlled designs) paradigms. O-Cam consists of a simulated Web conference during which participants are either ostracized or included by 2 other participants whose actions, unbeknownst to the participants, are actually pretaped. The findings of preliminary studies indicate that O-Cam provides a powerful ostracism experience that yields psychological and behavioral responses that are consistent with those in other ostracism paradigms (e.g., Cyberball; Williams, 2007). Moreover, unlike in many previous ostracism paradigms, O-Cam provides researchers with the flexibility to manipulate the physical appearance and the verbal/nonbehavior of the sources of ostracism without the need for confederates.

  16. Complementary and alternative medicine (CAM) following traumatic brain injury (TBI): Opportunities and challenges.

    Science.gov (United States)

    Hernández, Theresa D; Brenner, Lisa A; Walter, Kristen H; Bormann, Jill E; Johansson, Birgitta

    2016-06-01

    Traumatic brain injury (TBI) is highly prevalent and occurs in a variety of populations. Because of the complexity of its sequelae, treatment strategies pose a challenge. Given this complexity, TBI provides a unique target of opportunity for complementary and alternative medicine (CAM) treatments. The present review describes and discusses current opportunitites and challenges associated with CAM research and clinical applications in civilian, veteran and military service populations. In addition to a brief overview of CAM, the translational capacity from basic to clinical research to clinical practice will be described. Finally, a systematic approach to developing an adoptable evidence base, with proof of effectiveness based on the literature will be discussed. Inherent in this discussion will be the methodological and ethical challenges associated with CAM research in those with TBI and associated comorbidities, specifically in terms of how these challenges relate to practice and policy issues, implementation and dissemination. This article is part of a Special Issue entitled SI:Brain injury and recovery.

  17. Study on glass infiltrated alumina(GIA) ceramic for CAD/CAM

    Institute of Scientific and Technical Information of China (English)

    LI Mingzhe; LI Hong; WANG Wei; Zhao Yunfeng

    2001-01-01

    @@ With the rapid development of computer technique , Computer aided design(CAD) and computer aided manufacturing(CAM) or computer integrated manufacturing(CIM) has became an alternative to the conventional technique for producingdental restorations.

  18. Improving Convection and Cloud Parameterization Using ARM Observations and NCAR Community Atmosphere Model CAM5

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Guang J. [Univ. of California, San Diego, CA (United States)

    2016-11-07

    The fundamental scientific objectives of our research are to use ARM observations and the NCAR CAM5 to understand the large-scale control on convection, and to develop improved convection and cloud parameterizations for use in GCMs.

  19. CAD/CAM/CAI Application for High-Precision Machining of Internal Combustion Engine Pistons

    Directory of Open Access Journals (Sweden)

    V. V. Postnov

    2014-07-01

    Full Text Available CAD/CAM/CAI application solutions for internal combustion engine pistons machining was analyzed. Low-volume technology of internal combustion engine pistons production was proposed. Fixture for CNC turning center was designed.

  20. An automated qualification framework for the MeerKAT CAM (Control-And-Monitoring)

    Science.gov (United States)

    van den Heever, Lize; Marais, Neilen; Slabber, Martin

    2016-08-01

    This paper introduces and discusses the design of an Automated Qualification Framework (AQF) that was developed to automate as much as possible of the formal Qualification Testing of the Control And Monitoring (CAM) subsystem of the 64 dish MeerKAT radio telescope currently under construction in the Karoo region of South Africa. The AQF allows each Integrated CAM Test to reference the MeerKAT CAM requirement and associated verification requirement it covers and automatically produces the Qualification Test Procedure and Qualification Test Report from the test steps and evaluation steps annotated in the Integrated CAM Tests. The MeerKAT System Engineers are extremely happy with the AQF results, but mostly by the approach and process it enforces.

  1. CamOn: A Real-Time Autonomous Camera Control System

    DEFF Research Database (Denmark)

    Burelli, Paolo; Jhala, Arnav Harish

    2009-01-01

    contributes to the potential field that is used to determine po- sition and movement of the camera. Composition constraints for the camera are modelled as potential fields for controlling the view target of the camera. CamOn combines the compositional benefits of constraint- based camera systems, and improves......This demonstration presents CamOn, an autonomous cam- era control system for real-time 3D games. CamOn employs multiple Artificial Potential Fields (APFs), a robot motion planning technique, to control both the location and orienta- tion of the camera. Scene geometry from the 3D environment...... on real-time motion planning of the camera. Moreover, the recasting of camera constraints into potential fields is visually more accessible to game designers and has the potential to be implemented as a plug-in to 3D level design and editing tools currently avail- able with games. Introduction...

  2. Involvement of Ca2+/CaM in the signal transduction of acetylcholine regulating stomatal movement

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    It has been known that the neurotransmitter acetylcholine (ACh) also exists in plants and is able to regulate the movement of stomata. In another aspect, Ca2+/CaM as the second messengers have a critical role of signal transduction in stomatal guard-cell. Here we showed that Ca2+/CaM were also involved in theACh regulated stomatal movement. In the medium containing Ca2+, the Ca2+ channel blockers (NIF and Ver) and CaM inhibitors (TFP and W7) could neutralize the ACh induced stomatal opening, however, they are ineffective in the medium containing K+. Those results indicated that Ca2+/CaM were involved in the signal transduction pathway of ACh regulating stomatal movement.

  3. SuperCam Remote Sensing on the Mars 2020 Rover: Science Goals and Overview

    Science.gov (United States)

    Wiens, R. C.; Maurice, S.; Rull, F.; SuperCam Team

    2016-10-01

    The Mars 2020 Science Definition Team (SDT) report emphasized the importance of fine-scale measurements, suggesting that the numerous pin-point observations made at remote distances by ChemCam was a very desirable capability.

  4. A Unique Opportunity for an Intercultural Discussion on CAM and Liver Disease

    Directory of Open Access Journals (Sweden)

    Francesco Marotta

    2005-01-01

    Full Text Available The meeting of the APASL, Asian Pacific Association for the Study of the Liver, was held in December 2004, in New Delhi, India. The meeting was held under the patronage of the APASL Committee and Board of Presidents of the National Liver Association and in conjunction with the annual conference of the Indian Association for the Study of Liver (INASL. The congress was designed to have a core meeting with three parallel sessions running throughout, dedicated research workshops and intensive breakfast sessions. This report concentrates on the two sessions devoted to complementary and alternative medicine (CAM and shows the latest research in CAM for liver disease and the concerns of doctors about integrating CAM with more traditional treatments. With researchers and practitioners gathering from all over the world, it was a unique opportunity for an intercultural discussion on CAM and liver disease.

  5. The In Ovo Chick Chorioallantoic Membrane (CAM) Assay as an Efficient Xenograft Model of Hepatocellular Carcinoma

    National Research Council Canada - National Science Library

    Li, Michael; Pathak, Ravi R; Lopez-Rivera, Esther; Friedman, Scott L; Aguirre-Ghiso, Julio A; Sikora, Andrew G

    2015-01-01

    .... More recently, the CAM assay has been modified to work as an in vivo xenograft model system for various cancers that bridges the gap between basic in vitro work and more complex animal cancer models...

  6. Commissioning and First Observations with Wide FastCam at the Telescopio Carlos S\\'anchez

    CERN Document Server

    Velasco, Sergio; Oscoz, Alejandro; López, Roberto L; Puga, Marta; Murga, Gaizka; Pérez-Garrido, Antonio; Pallé, Enric; Ricci, Davide; Ayuso, Ismael; Hernández-Sánchez, Mónica; Truant, Nicola

    2016-01-01

    The FastCam instrument platform, jointly developed by the IAC and the UPCT, allows, in real-time, acquisition, selection and storage of images with a resolution that reaches the diffraction limit of medium-sized telescopes. FastCam incorporates a specially designed software package to analyse series of tens of thousands of images in parallel with the data acquisition at the telescope. Wide FastCam is a new instrument that, using the same software for data acquisition, does not look for lucky imaging but fast observations in a much larger field of view. Here we describe the commissioning process and first observations with Wide FastCam at the Telescopio Carlos S\\'anchez (TCS) in the Observatorio del Teide.

  7. Health psychology as a context for massage therapy: a conceptual model with CAM as mediator.

    Science.gov (United States)

    Hymel, Glenn M; Rich, Grant J

    2014-04-01

    Health psychology represents a context within which massage therapy research, education, and practice can be positioned for the mutual benefit of both. Furthermore, complementary and alternative medicine (CAM) more often than not plays a mediating role in relating massage therapy to health psychology. On occasion, though, the linkage between health psychology and massage therapy can be quite direct without the mediating influence of CAM. This paper, accordingly, advances a conceptual model via both flowchart and Venn diagram displays for viewing the health psychology context for massage therapy with the possibility of CAM as a mediating factor. Attention is also given to the broad range of issues constituting contemporary health psychology as well as its correspondence to an equally diverse array of client populations and health conditions addressed in massage therapy research. Future directions in the areas of health psychology, CAM, and massage therapy are proposed with a view toward a mutual and reciprocal benefit accruing to these behavioral and health science arenas.

  8. Cooverexpression of EpCAM and c-myc genes in malignant breast tumours

    Indian Academy of Sciences (India)

    SAMIRA SADEGHI; ZOHREH HOJATI; HOSSEIN TABATABAEIAN

    2017-03-01

    The overexpression of epithelial cell adhesion molecule (EpCAM), a proto-oncogene, affects progression, treatment, and diagnosis of many adenocarcinomas. C-myc has been shown to be a downstream target of EpCAM and is also one of the most important proto-oncogenes routinely overexpressed in breast cancer. However, cooverexpression of EpCAM and c-mycgenes has not been investigated in breast cancer tissues, particularly in Iranian population. The aim of this study was to assess the expression of EpCAM and c-myc genes in malignant breast cancer tissues using reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) followed by analyses of the association between the outcomes. In this study, 122 fresh tissues, including 104 malignant and 18 benign samples, were disrupted by mortar and pestle, and then the RNA was isolated from the samples and converted to cDNA. The relative expression levels of EpCAM and c-myc genes were measured by2−ΔΔCt method using RT-qPCR. EpCAM protein level was also assessed in 66 cases using Western blot technique. UsingRT-qPCR method, our results showed that EpCAM was overexpressed in 48% of malignant and 11.1% of benign samples. Evaluating EpCAM protein overexpression in a portion of samples depicted the fully concordance rate between Western blot and RT-qPCR techniques. C-myc expression was first evaluated by RT-qPCR method, showing the overexpression rate of 39%and 28% in malignant and benign samples, respectively. These data were also quite concordant with the clinically available immunohistochemistry reports of the same samples studied in this study. Importantly, overexpression of EpCAM and c-myc was significantly associated and showed an agreement of 57.3%. This study demonstrated the cooverexpression of EpCAM and c-myc in breast tumours collected from breast cancer patients of the Iranian population. EpCAM and c-myc positive cases were significantly associated with reduced and enhanced risk of ER/PR positivity

  9. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2017-05-12

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM

  10. Cooverexpression of EpCAM and c-myc genes in malignant breast tumours.

    Science.gov (United States)

    Sadeghi, Samira; Hojati, Zohreh; Tabatabaeian, Hossein

    2017-03-01

    The overexpression of epithelial cell adhesion molecule (EpCAM), a proto-oncogene, affects progression, treatment, and diagnosis of many adenocarcinomas. C-myc has been shown to be a downstream target of EpCAM and is also one of the most important proto-oncogenes routinely overexpressed in breast cancer. However, cooverexpression of EpCAM and c-myc genes has not been investigated in breast cancer tissues, particularly in Iranian population. The aim of this study was to assess the expression of EpCAM and c-myc genes in malignant breast cancer tissues using reverse transcriptase-quantitative polymerase chain reaction (RT-qPCR) followed by analyses of the association between the outcomes. In this study, 122 fresh tissues, including 104 malignant and 18 benign samples, were disrupted by mortar and pestle, and then the RNA was isolated from the samples and converted to cDNA. The relative expression levels of EpCAM and c-myc genes were measured by 2(-ΔΔCt) method using RT-qPCR. EpCAM protein level was also assessed in 66 cases using Western blot technique. Using RT-qPCR method, our results showed that EpCAM was overexpressed in 48% of malignant and 11.1% of benign samples. Evaluating EpCAM protein overexpression in a portion of samples depicted the fully concordance rate between Western blot and RT-qPCR techniques. C-myc expression was first evaluated by RT-qPCR method, showing the overexpression rate of 39% and 28% in malignant and benign samples, respectively. These data were also quite concordant with the clinically available immunohistochemistry reports of the same samples studied in this study. Importantly, overexpression of EpCAM and c-myc was significantly associated and showed an agreement of 57.3%. This study demonstrated the cooverexpression of EpCAM and c-myc in breast tumours collected from breast cancer patients of the Iranian population. EpCAM and c-myc positive cases were significantly associated with reduced and enhanced risk of ER/PR positivity

  11. Understanding, perceptions and self-use of complementary and alternative medicine (CAM) among Malaysian pharmacy students.

    Science.gov (United States)

    Hasan, Syed S; Yong, Chew S; Babar, Muneer G; Naing, Cho M; Hameed, Abdul; Baig, Mirza R; Iqbal, Shahid M; Kairuz, Therese

    2011-10-13

    In recent times the basic understanding, perceptions and CAM use among undergraduate health sciences students have become a topic of interest. This study was aimed to investigate the understanding, perceptions and self-use of CAM among pharmacy students in Malaysia. This cross-sectional study was conducted on 500 systematically sampled pharmacy students from two private and one public university. A validated, self-administered questionnaire comprised of seven sections was used to gather the data. A systematic sampling was applied to recruit the students. Both descriptive and inferential statistics were applied using SPSS® version 18. Overall, the students tend to disagree that complementary therapies (CM) are a threat to public health (mean score = 3.6) and agreed that CMs include ideas and methods from which conventional medicine could benefit (mean score = 4.7). More than half (57.8%) of the participants were currently using CAM while 77.6% had used it previously. Among the current CAM modalities used by the students, CM (21.9%) was found to be the most frequently used CAM followed by Traditional Chinese Medicine (TCM) (21%). Most of the students (74.8%) believed that lack of scientific evidence is one of the most important barriers obstructing them to use CAM. More than half of the students perceived TCM (62.8%) and music therapy (53.8%) to be effective. Majority of them (69.3%) asserted that CAM knowledge is necessary to be a well-rounded professional. This study reveals a high-percentage of pharmacy students who were using or had previously used at least one type of CAM. Students of higher professional years tend to agree that CMs include ideas and methods from which conventional medicine could benefit.

  12. Understanding, perceptions and self-use of complementary and alternative medicine (CAM among Malaysian pharmacy students

    Directory of Open Access Journals (Sweden)

    Baig Mirza R

    2011-10-01

    Full Text Available Abstract Background In recent times the basic understanding, perceptions and CAM use among undergraduate health sciences students have become a topic of interest. This study was aimed to investigate the understanding, perceptions and self-use of CAM among pharmacy students in Malaysia. Methods This cross-sectional study was conducted on 500 systematically sampled pharmacy students from two private and one public university. A validated, self-administered questionnaire comprised of seven sections was used to gather the data. A systematic sampling was applied to recruit the students. Both descriptive and inferential statistics were applied using SPSS® version 18. Results Overall, the students tend to disagree that complementary therapies (CM are a threat to public health (mean score = 3.6 and agreed that CMs include ideas and methods from which conventional medicine could benefit (mean score = 4.7. More than half (57.8% of the participants were currently using CAM while 77.6% had used it previously. Among the current CAM modalities used by the students, CM (21.9% was found to be the most frequently used CAM followed by Traditional Chinese Medicine (TCM (21%. Most of the students (74.8% believed that lack of scientific evidence is one of the most important barriers obstructing them to use CAM. More than half of the students perceived TCM (62.8% and music therapy (53.8% to be effective. Majority of them (69.3% asserted that CAM knowledge is necessary to be a well-rounded professional. Conclusions This study reveals a high-percentage of pharmacy students who were using or had previously used at least one type of CAM. Students of higher professional years tend to agree that CMs include ideas and methods from which conventional medicine could benefit.

  13. Genome sequence of a new Streptomyces coelicolor generalized transducing bacteriophage, ΦCAM.

    Science.gov (United States)

    Monson, Rita; Salmond, George P C

    2012-12-01

    Streptomyces coelicolor is a model system for the study of Streptomyces, a genus of bacteria responsible for the production of many clinically important antibiotics. Here we report the genome sequence of ΦCAM, a new S. coelicolor generalized transducing bacteriophage, isolated from a soil sample originating from Lincolnshire, United Kingdom. Many open reading frames within ΦCAM shared high levels of similarity to a prophage from Salinispora tropica and a putative prophage in Streptomyces sp. strain C.

  14. CAM within a field force of countervailing powers: The case of Portugal.

    Science.gov (United States)

    Almeida, Joana; Gabe, Jonathan

    2016-04-01

    This paper examines the extent to which the position of the medical profession and the state towards complementary and alternative medicine (CAM) practitioners has changed since the late 1990s, taking Portugal as a case study. Using Light's concept of countervailing powers, we consider the alliances, interests, rhetoric and degrees of control between these three actors over time, focussing particularly on the extent to which CAM practitioners have acted as a countervailing force in their relationship with the medical profession and the state. It also brings to the fore the position of supra-state agencies concerning CAM regulation. A critical discourse analysis was conducted on data derived from a systematic search of information dating from the late 1990s up to 2015. Our analysis suggests that CAM has emerged as an active player and a countervailing power in that it has had significant influence on the process of state policy-making. The medical profession, in turn, has moved from rejecting to 'incorporating' CAM, while the state has acted as a 'broker', trying to accommodate the demands and preferences of both actors while simultaneously demonstrating its power and autonomy in shaping health policy. In sum, the history of countermoves of CAM, the medical profession and the state in recasting power relations regarding CAM regulation in Portugal has highlighted the explanatory value of Light's countervailing power theory and the need to move away from a professional dominance and corporatist approach, in which CAM has simply been seen as subjugated to the power of the medical profession and the state.

  15. PillCam ESO versus esophagogastroduodenoscopy in esophageal variceal screening: A decision analysis.

    Science.gov (United States)

    White, Christopher M; Kilgore, Meredith L

    2009-01-01

    PillCam ESO has been evaluated as a possible strategy to screen patients with cirrhosis for esophageal varices, but current guidelines recommend patients undergo screening with esophagogastroduodenoscopy (EGD), as it is currently the gold standard. Although recent data have suggested that PillCam ESO may be an acceptable alternative for screening, there is limited data on its cost-effectiveness compared with other screening modalities. This study was performed to compare the cost-effectiveness of PillCam ESO versus EGD for esophageal variceal screening. Markov models were constructed to compare 2 screening strategies: PillCam ESO versus EGD. In each arm, patients were followed for a time horizon of 15 years in 1-year transition intervals. All variables, transition probabilities, and costs were derived from the medical literature, and sensitivity analyses were performed on the different variables in the model. Base-case analysis shows that PillCam ESO is associated with an average expected cost of $22,589 and an average expected effectiveness measure of 12.81 life-years. EGD is associated with an average expected cost of $23,083 and an average expected effectiveness measure of 12.67 life-years. PillCam ESO was found to dominate EGD as a screening strategy for patients with cirrhosis. Sensitivity analyses found several variables within the model to have influential effects on the results. PillCam ESO is the dominant strategy for screening patients with cirrhosis for esophageal varices. However, based on a small difference in costs and effectiveness between each strategy, the results would suggest that PillCam ESO and EGD are essentially equivalent strategies.

  16. Cognitive interviews guide design of a new CAM patient expectations questionnaire

    OpenAIRE

    Sherman, Karen J.; Eaves, Emery R; Ritenbaugh, Cheryl; Hsu, Clarissa; Cherkin, Daniel C; Turner, Judith A

    2014-01-01

    Background No consistent relationship exists between pre-treatment expectations and therapeutic benefit from various complementary and alternative medicine (CAM) therapies in clinical trials. However, many different expectancy measures have been used in those studies, with no validated questionnaires clearly focused on CAM and pain. We undertook cognitive interviews as part of a process to develop and validate such a questionnaire. Methods We reviewed questions about expectations of benefits ...

  17. EpCAM-independent capture of circulating tumor cells with a 'universal CTC-chip'.

    Science.gov (United States)

    Chikaishi, Yasuhiro; Yoneda, Kazue; Ohnaga, Takashi; Tanaka, Fumihiro

    2017-01-01

    Capture of circulating tumor cells (CTCs), which are shed from the primary tumor site and circulate in the blood, remains a technical challenge. CellSearch® is the only clinically approved CTC detection system, but has provided only modest sensitivity in detecting CTCs mainly because epithelial cell adhesion molecule (EpCAM)-negative tumor cells may not be captured. To achieve more sensitive CTC‑capture, we have developed a novel microfluidic platform, a 'CTC-chip' comprised of light-curable resins that has a unique advantage in that any capture antibody is easily conjugated. In the present study, we showed that EpCAM-negative tumor cells as well as EpCAM-positive cells were captured with the novel 'universal CTC-chip' as follows: i) human lung cancer cells (PC-9), with strong EpCAM expression, were efficiently captured with the CTC-chip coated with an anti-EpCAM antibody (with an average capture efficiency of 101% when tumor cells were spiked in phosphate‑buffered saline (PBS) and 88% when spiked in blood); ii) human mesothelioma cells (ACC-MESO-4), with no EpCAM expression but with podoplanin expression, were captured with the CTC-chip coated with an anti-podoplanin antibody (average capture efficiency of 78% when tumor cells were spiked in PBS and 38% when spiked in blood), whereas ACC-MESO-4 cells were not captured with the CTC-chip coated with the anti-EpCAM antibody. These results indicate that the novel 'CTC-chip' can be useful in sensitive EpCAM-independent detection of CTCs, which may provide new insights into personalized medicine.

  18. Women's attitude towards the use of complementary and alternative medicines (CAM) in pregnancy.

    Science.gov (United States)

    Warriner, Sian; Bryan, Karen; Brown, Anna Maria

    2014-01-01

    the popularity of non-prescription, over-the counter (OTC) medicines, vitamins, minerals, homoeopathic remedies and herbal supplements (CAM) has grown significantly in recent years. However, we have limited knowledge relating to why pregnant women use CAM and how this may relate to the provision of maternity care. Using an interview approach this study explored the nature of over-the-counter and complementary medicines use in a sample of pregnant women. this interview study formed part of a larger self-administered questionnaire survey on the extent of CAM use in pregnancy at large NHS Trust in England. The questionnaire provided the opportunity for women to complete a contact information reply slip if they were happy for follow-up interview. Audio recorded, face to face interviews were undertaken with a sample of 10 women. the reasons the women who were interviewed gave for using CAM broadly fell into two areas centred essentially on the contrasting advantages of CAM and disadvantages of conventional medicine. Doctors or midwives were rarely informed about the use of CAM medicines during pregnancy. the women saw CAM as outside of biomedicine and part of a holistic approach to health and well-being over which they are able to maintain their personal control. Non-disclosure of CAM use was common, a feature of which, appears to be some health-care professionals' lack of realisation of the importance, to women, of a holistic approach to their health, key to which is a desire to retain control over decisions associated with their well-being. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  20. Complementing a Rural Pharmacy Course with CAM: Reflections from a Decade of Experience

    Directory of Open Access Journals (Sweden)

    Maree Simpson

    2014-03-01

    Full Text Available Substantial complementary medicines (CAM use is reported worldwide. Australian consumers use CAM for health maintenance, minor self-limiting disease states, and also for chronic conditions. The increasing use of CAM has required pharmacists to become increasingly more knowledgeable about CAM and the ethics of CAM recommendation. When the first Australian non-metropolitan pharmacy program was started at Charles Sturt University, in 1997, it was decided to incorporate two innovative courses to assist rurally educated students to engage with health consumers who expect pharmacists to be able to assist them with CAM. This discussion traces and reflects on the development, implementation and current situation of the Complementary Medicines for Pharmacy course. Over time, this course has evolved from a final year elective with a focus on familiarization to a mandated course with a phytomedicine focus to an integrated topic in final year with a focus on evidence, quality of evidence and professional decision-making demonstrated in a reflective professional portfolio. Of potentially greater importance, however, has been the introduction of complementary medicines as a topic in every year of the course with the goal of facilitating effective professional engagement with health consumers.

  1. Mutation in the sixth immunoglobulin domain of L1CAM is associated with migrational brain anomalies

    Science.gov (United States)

    Shieh, Christine; Moser, Franklin; Graham, John M.; Watiker, Valerie

    2015-01-01

    Objective: To describe the phenotype of a patient with classical features of X-linked L1 syndrome associated with novel brain malformations. Methods: Diagnostic analysis included physical and dysmorphology examinations, MRI of the brain, and exome sequencing of the family trio. Results: We report a 2.5-year-old boy with developmental delay, dysmorphic facies, and adducted thumbs. MRI of the brain showed a truncated corpus callosum and periventricular heterotopias associated with polymicrogyria (PMG). Variant segregation analysis with exome sequencing discovered a novel maternally derived hemizygous variant in exon 14 of the L1CAM gene (c.1759 G>C; p.G587R). Conclusions: This novel L1CAM mutation was located in the protein's sixth immunoglobin domain and involved glycine-587, a key residue in the structure of L1CAM because of its interactions with lysine-606, which indicates that any mutation at this site would likely affect the secondary structure and function of the protein. The replacement of the small nonpolar glycine residue with a large basic arginine would have an even more dramatic result. The presentation of periventricular nodular heterotopias with overlying PMG is very uncommon, and its association with L1CAM may provide insight into other similar cases. Furthermore, this presentation indicates the important role that L1CAM plays in neuronal migration and brain development and extends the phenotype associated with L1CAM-associated disorders. PMID:27066571

  2. SenseCam reminiscence and action recall in memory-unimpaired people.

    Science.gov (United States)

    Seamon, John G; Moskowitz, Tacie N; Swan, Ashley E; Zhong, Boyuan; Golembeski, Amy; Liong, Christopher; Narzikul, Alexa C; Sosan, Olumide A

    2014-01-01

    Case studies of memory-impaired individuals consistently show that reminiscing with SenseCam images enhances event recall. This exploratory study examined whether a similar benefit would occur for the consolidation of memories in memory-unimpaired people. We tested delayed recall for atypical actions observed on a lengthy walk. Participants used SenseCam, a diary, or no external memory aid while walking, followed by reminiscence with SenseCam images, diary entries, or no aid, either alone (self-reminiscence) or with the experimenter (social reminiscence). One week later, when tested without SenseCam images or diary entries, prior social reminiscence produced greater recall than self-reminiscence, but there were no differences between memory aid conditions for action free recall or action order recall. When methodological variables were controlled, there was no recall advantage for SenseCam reminiscence with memory-unimpaired participants. The case studies and present study differ in multiple ways, making direct comparisons problematic. SenseCam is a valuable aid to the memory impaired, but its mnemonic value for non-clinical populations remains to be determined.

  3. Validation of aerosols, reactive gases and greenhouse gases in the CAMS forecasts, analyses and reanalyses

    Science.gov (United States)

    Eskes, Henk; Basart, Sara; Blechschmidt, Anne; Chabrillat, Simon; Clark, Hannah; Cuevas, Emilio; Engelen, Richard; Kapsomenakis, John; Katragkou, Eleni; Mantzius Hansen, Kaj; Niemeijer, Sander; Ramonet, Michel; Schulz, Michael; Sudarchikova, Natalia; Wagner, Annette; Warneke, Thorsten

    2016-04-01

    The Atmosphere Monitoring Service of the European Copernicus Programme (CAMS) is an operational service providing analyses, reanalyses and daily forecasts of aerosols, reactive gases and greenhouse gases on a global scale, and air quality forecasts and reanalyses on a regional scale. CAMS is based on the systems developed during the European MACC I-II-III (Monitoring Atmospheric Composition and Climate) research projects. In CAMS data assimilation techniques are applied to combine in-situ and remote sensing observations with global and European-scale models of atmospheric reactive gases, aerosols and greenhouse gases. The global component is based on the Integrated Forecast System of the ECMWF, and the regional component on an ensemble of 7 European air quality models. CAMS is implemented by ECMWF, and the transition from MACC to CAMS is currently being implemented (2015-2016). CAMS has a dedicated validation activity, a partnership of 13 institutes co-ordinated by KNMI, to document the quality of the atmospheric composition products. In our contribution we discuss this validation activity, including the measurement data sets, validation requirements, the operational aspects, the upgrade procedure, the validation reports and scoring methods, and the model configurations and assimilation systems validated. Of special concern are the forecasts of high pollution concentration events (fires, dust storms, air pollution events, volcano ash and SO2). A few interesting validation results will be shown.

  4. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  5. The Systemic Theory of Living Systems and Relevance to CAM

    Directory of Open Access Journals (Sweden)

    José A. Olalde Rangel

    2005-01-01

    Full Text Available The Systemic Theory of Living Systems is being published in several parts in eCAM. The theory is axiomatic. It originates from the phenomenological idea that physiological health is based on three factors: integrity of its structure or organization, O, functional organic energy reserve, E, and level of active biological intelligence, I. From the theory is derived a treatment strategy called Systemic Medicine (SM. This is based on identifying and prescribing phytomedicines and/or other medications that strengthen each factor. Energy-stimulating phytomedicines increase available energy and decrease total entropy of an open biological system by providing negative entropy. The same occurs with phytomedicines that act as biological intelligence modulators. They should be used as the first line of treatment in all ailments, since all pathologies, by definition, imply a higher than normal organic entropy. SM postulates that the state of health, H, of an individual, is effectively equal to the product of the strength of each factor H = O × E × I. SM observes that when all three factors are brought back to ideal levels, patients' conditions begin the recovery to normal health.

  6. SuprimeCam Observation of Sporadic Meteors during Perseids 2004

    CERN Document Server

    Iye, M; Yanagisawa, M; Ebizuka, N; Ohnishi, K; Hirose, C; Asami, N; Komiyama, Yu; Furusawa, H

    2007-01-01

    We report the serendipitous findings of 13 faint meteors and 44 artificial space objects by Subaru SuprimeCam imaging observations during 11-16 August 2004. The meteors, at about 100km altitude, and artificial satellites/debris in orbit, at 500km altitude or higher, were clearly discriminated by their apparent defocused image sizes. CCD photometry of the 13 meteors, including 1 Perseid, 1 Aquarid, and 11 sporadic meteors, was performed. We defined a peak video-rate magnitude by comparing the integrated photon counts from the brightest portion of the track traversed within 33ms to those from a 0-mag star during the same time duration. This definition gives magnitudes in the range 4.0< V_{vr} <6.4 and 4.1< I_{vr}<5.9 for these 13 meteors. The corresponding magnitude for virtual naked-eye observers could be somewhat fainter especially for the V-band observation, in which the [OI] 5577 line lasting about 1 sec as an afterglow could contribute to the integrated flux of the present 5-10 min CCD exposure...

  7. Weak gravitational lensing with the Hyper Suprime-Cam survey

    Science.gov (United States)

    Mandelbaum, Rachel; Hyper Suprime-Cam (HSC) Collaboration

    2017-01-01

    Data from the Hyper Suprime-Cam (HSC) survey on the Subaru telescope show great promise for weak gravitational lensing science. The unprecedented combination of area, depth, and imaging quality of this survey (with median i-band seeing of 0.6 arcsec) will enable a wide array of weak lensing measurements, with significant contributions from lenses up to redshift z~1. Applications include cosmological weak lensing measurements from shear-shear and galaxy-shear correlations, which will be especially powerful when combined with the overlapping SDSS-III spectroscopic datasets; and studies of the dark matter halos of galaxies and galaxy clusters. In this talk, I will demonstrate the imaging quality and the tests used to validate the weak lensing measurements. These include null tests internal to the data, comparisons with external datasets, and image simulation-based tests. I will also show the lensing mass profiles of spectroscopic galaxies from the SDSS-III, illustrating the current signal-to-noise ratio on small and large scales and demonstrating the potential for innovative galaxy and cosmological science with the complete survey area.

  8. Novel Diagnosis of Lyme Disease: Potential for CAM Intervention

    Directory of Open Access Journals (Sweden)

    Aristo Vojdani

    2009-01-01

    Full Text Available Lyme disease (LD is the most common tick-borne disease in the northern hemisphere, producing a wide range of disabling effects on multiple human targets, including the skin, the nervous system, the joints and the heart. Insufficient clinical diagnostic methods, the necessity for prompt antibiotic treatment along with the pervasive nature of infection impel the development and establishment of new clinical diagnostic tools with increased accuracy, sensitivity and specificity. The goal of this article is 4-fold: (i to detail LD infection and pathology, (ii to review prevalent diagnostic methods, emphasizing inherent problems, (iii to introduce the usage of in vivo induced antigen technology (IVIAT in clinical diagnostics and (iv to underscore the relevance of a novel comprehensive LD diagnostic approach to practitioners of Complementary and Alternative Medicine (CAM. Utilization of this analytical method will increase the accuracy of the diagnostic process and abridge the time to treatment, with antibiotics, herbal medicines and nutritional supplements, resulting in improved quality of care and disease prognosis.

  9. Fringing in MonoCam Y4 filter images

    Science.gov (United States)

    Brooks, J.; Fisher-Levine, M.; Nomerotski, A.

    2017-05-01

    We study the fringing patterns observed in MonoCam, a camera with a single Large Synoptic Survey Telescope (LSST) CCD sensor. Images were taken at the U.S. Naval Observatory in Flagstaff, Arizona (NOFS) employing its 1.3 m telescope and an LSST y4 filter. Fringing occurs due to the reflection of infrared light (700 nm or larger) from the bottom surface of the CCD which constructively or destructively interferes with the incident light to produce a net ``fringe'' pattern which is superimposed on all images taken. Emission lines from the atmosphere, dominated by hydroxyl (OH) spectra, can change in their relative intensities as the night goes on, producing different fringe patterns in the images taken. We found through several methods that the general shape of the fringe patterns remained constant, though with slight changes in the amplitude and phase of the fringes. We also found that a superposition of fringes from two monochromatic lines taken in the lab offered a reasonable description of the sky data.

  10. CanariCam/GTC observations of (99942) Apophis

    CERN Document Server

    Licandro, J; Alvarez, C; Alí-Lagoa, V; Delbò, M

    2015-01-01

    The potentially hazardous asteroid (PHA) (99942) Apophis is one of the most remarkable near-Earth asteroids (NEA) in terms of impact hazard. A good determination of its surface thermal inertia is very important in order to evaluate the Yarkovsky effect on its orbital evolution. We present thermal infrared observations obtained on January 29, 2013, with CanariCam mid-infrared camera/spectrograph attached to the Gran Telescopio CANARIAS (GTC, Roque de los Muchachos Observatory, La Palma, Spain) using the Si2-8.7, Si6-12.5, and Q1-17.65 filters with the aim of deriving Apophis' diameter ($D$), geometric albedo ($p_V$), and thermal inertia ($\\Gamma$). We performed a detailed thermophysical model analysis of the GTC data combined with previously published thermal data obtained using Herschel Space Observatory PACS instrument at 70, 100, and 160 $\\mu$m.The thermophysical model fit of the data favors low surface roughness solutions (within a range of roughness slope angles $rms$ between 0.1 and 0.5), and constrains ...

  11. EpCAM Aptamer-siRNA Chimera Targets and Regress Epithelial Cancer.

    Directory of Open Access Journals (Sweden)

    Nithya Subramanian

    Full Text Available Epithelial cell adhesion molecule (EpCAM, a cancer stem cell (CSC marker is over expressed in epithelial cancers and in retinoblastoma (RB. We fabricated an EpCAM targeting aptamer-siRNA chimera and investigated its anti-tumor property and EpCAM intracellular domain (EpICD mediated signaling in epithelial cancer. The anti-tumor efficacy of EpCAM aptamer-siEpCAM chimera (EpApt-siEp was evaluated by qPCR, northern and Western blotting in WERI-Rb1- RB cell line, primary RB tumor cells and in MCF7- breast cancer cell line. Anti-tumor activity of EpApt-siEp was studied in vivo using epithelial cancer (MCF7 mice xenograft model. The mechanism and pathways involved in the anti-tumor activity was further studied using protein arrays and qPCR. EpApt-siEp chimera was processed in vitro by dicer enzyme. Treatment of the WERI-Rb1 and MCF7 cells with EpApt-siEp revealed statistically significant down regulation of EpCAM expression (P<0.005 and concomitant reduction in cellular proliferation. In primary RB cells cultured from RB tumors, EpApt-siEp silenced EpCAM, significantly inhibited (P<0.01 cell proliferation and induced cytotoxicity. Knockdown of EpICD expressed in RB primary tumors led to repression of pluripotency markers, SOX2, OCT4, NANOG, and CD133. In vivo studies showed complete tumor growth regression without any toxicity in animals (P<0.001 and tumor tissues showed significant downregulation (P<0.05 of EpCAM, MRP1, ABCG2, stathmin, survivin and upregulation of ATM (P<0.05 leading to apoptosis by intrinsic pathway with minor alteration in cytokines. Our results revealed that EpApt-siEp potentially eradicated EpCAM positive cancer cells through CSC marker suppression and apoptosis, while sparing normal EpCAM negative adjacent cells.

  12. Advances in computer-aided engineering: CAD/CAM-research at Delft University of Technology. Report of the VF-project CAD/CAM 1989-1994

    NARCIS (Netherlands)

    1994-01-01

    This book contains a collection of articles describing on-going CAD/CAM-research at several engineering faculties at Delft University of Technology. Two main themes covered in this book are 'Conceptual design of complex products' and 'Product modelling and product data exchange'.

  13. Advances in computer-aided engineering: CAD/CAM-research at Delft University of Technology. Report of the VF-project CAD/CAM 1989-1994

    NARCIS (Netherlands)

    1994-01-01

    This book contains a collection of articles describing on-going CAD/CAM-research at several engineering faculties at Delft University of Technology. Two main themes covered in this book are 'Conceptual design of complex products' and 'Product modelling and product data exchange'.

  14. Ventricular assist device

    Science.gov (United States)

    VAD; RVAD; LVAD; BVAD; Right ventricular assist device; Left ventricular assist device; Biventricular assist device; Heart pump; Left ventricular assist system; LVAS; Implantable ventricular assist device

  15. Additive CAD/CAM process for dental prostheses.

    Science.gov (United States)

    Silva, Nelson R F A; Witek, Lukasz; Coelho, Paulo G; Thompson, Van P; Rekow, Elizabeth D; Smay, Jim

    2011-02-01

    This article describes the evolution of a computer-aided design/computer-aided manufacturing (CAD/CAM) process where ceramic paste is deposited in a layer-by-layer sequence using a computer numerical control machine to build up core and fixed partial denture (FPD) structures (robocasting). Al(2)O(3) (alumina) or ZrO(2) (Y-TZP) are blended into a 0.8% aqueous solution of ammonium polyacrylate in a ratio of approximately 1:1 solid:liquid. A viscosifying agent, hydroxypropyl methylcellulose, is added to a concentration of 1% in the liquid phase, and then a counter polyelectrolyte is added to gel the slurry. There are two methods for robocasting crown structures (cores or FPD framework). One is for the core to be printed using zirconia ink without support materials, in which the stereolithography (STL) file is inverted (occlusal surface resting on a flat substrate) and built. The second method uses a fugitive material composed of carbon black codeposited with the ceramic material. During the sintering process, the carbon black is removed. There are two key challenges to successful printing of ceramic crowns by the robocasting technique. First is the development of suitable materials for printing, and second is the design of printing patterns for assembly of the complex geometry required for a dental restoration. Robocasting has room for improvement. Current development involves enhancing the automation of nozzle alignment for accurate support material deposition and better fidelity of the occlusal surface. An accompanying effort involves calculation of optimal support structures to yield the best geometric results and minimal material usage.

  16. From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites.

    Science.gov (United States)

    Mainjot, A K; Dupont, N M; Oudkerk, J C; Dewael, T Y; Sadoun, M J

    2016-05-01

    Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design-computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks-especially high temperature (HT) and, most of all, high temperature-high pressure (HT-HP)-are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks-particularly experimental PICNs-can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as "no prep" treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial

  17. Information management and complementary alternative medicine: the anatomy of information about CAMs through PubMed.

    Science.gov (United States)

    Corrao, Salvatore; Argano, Christiano; Colomba, Daniela; Ippolito, Calogero; Gargano, Vincenzo; Arcoraci, Vincenzo; Licata, Giuseppe

    2013-10-01

    In recent years, there has been a growing interest about complementary and alternative medicine (CAM), and the use of CAM interventions has become more common among people. For these reasons, health professionals must be able to effectively manage information in this field of knowledge according to an evidence-based point of view. This study assessed the anatomy of the available information about CAMs using PubMed, to give practical instructions to manage information in this field. We also analyzed the anatomy of information according to each alternative medicine branch, narrow and broad search methods, subset filters for indexed-for-Medline and non-indexed citations, and different publication types including randomized controlled trials (RCTs) and meta-analyses. Our results demonstrated that the use of CAMs subset (supplied by PubMed search engine) leads to a great number of citations determining an information overload. Our data reveal that it would be more useful to search for the CAM separately, identifying specific items and study design. Moreover, we found the largest number of randomized clinical trials and meta-analyses related to herbal medicine and acupuncture, neither RCTs nor meta-analyses were available for bach and flower remedies, auriculoacupuncture, iridology, and pranotherapy. For the first time, our study gives a comprehensive view of the anatomy of information regarding CAMs and each branch of them. We suggest a methodological approach to face with searching information about this emerging issue from an evidence-based point of view. Finally, our data pointed out some "grey zones" since neither RCTs nor meta-analyses were available for some CAMs.

  18. Correlation between citric acid and nitrate metabolisms during CAM cycle in the atmospheric bromeliad Tillandsia pohliana.

    Science.gov (United States)

    Freschi, Luciano; Rodrigues, Maria Aurineide; Tiné, Marco Aurélio Silva; Mercier, Helenice

    2010-12-15

    Crassulacean acid metabolism (CAM) confers crucial adaptations for plants living under frequent environmental stresses. A wide metabolic plasticity can be found among CAM species regarding the type of storage carbohydrate, organic acid accumulated at night and decarboxylating system. Consequently, many aspects of the CAM pathway control are still elusive while the impact of this photosynthetic adaptation on nitrogen metabolism has remained largely unexplored. In this study, we investigated a possible link between the CAM cycle and the nitrogen assimilation in the atmospheric bromeliad Tillandsia pohliana by simultaneously characterizing the diel changes in key enzyme activities and metabolite levels of both organic acid and nitrate metabolisms. The results revealed that T. pohliana performed a typical CAM cycle in which phosphoenolpyruvate carboxylase and phosphoenolpyruvate carboxykinase phosphorylation seemed to play a crucial role to avoid futile cycles of carboxylation and decarboxylation. Unlike all other bromeliads previously investigated, almost equimolar concentrations of malate and citrate were accumulated at night. Moreover, a marked nocturnal depletion in the starch reservoirs and an atypical pattern of nitrate reduction restricted to the nighttime were also observed. Since reduction and assimilation of nitrate requires a massive supply of reducing power and energy and considering that T. pohliana lives overexposed to the sunlight, we hypothesize that citrate decarboxylation might be an accessory mechanism to increase internal CO₂ concentration during the day while its biosynthesis could provide NADH and ATP for nocturnal assimilation of nitrate. Therefore, besides delivering photoprotection during the day, citrate might represent a key component connecting both CAM pathway and nitrogen metabolism in T. pohliana; a scenario that certainly deserves further study not only in this species but also in other CAM plants that nocturnally accumulate citrate

  19. Separating device

    NARCIS (Netherlands)

    De Jong, T.P.R.

    2001-01-01

    A sorting device (1) suitable for sorting wire from a waste stream, comprising a body (2) that moves when in use, and provided with spikes or similar projections. The body is embodied as a rotatable roll (2), which oscillates axially during its rotation. The roll is coupled to an oscillation engine

  20. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  1. Assistive Devices

    Science.gov (United States)

    ... a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get dressed. Some are high-tech tools, such as computers. Others are much simpler, ...

  2. Printing Device

    NARCIS (Netherlands)

    Berg, van den M.J.; Markies, P.R.; Zuilhof, H.

    2014-01-01

    An ink jetprinting device includes a pressure chamber formed by a plurality of wall segments, a first aperture extending through a wall segment and communicating with an ink jet orifice and a second aperture extending through a wall segment and communicating with an ink supply duct. The pressure

  3. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  4. Printing Device

    NARCIS (Netherlands)

    Berg, van den M.J.; Markies, P.R.; Zuilhof, H.

    2014-01-01

    An ink jetprinting device includes a pressure chamber formed by a plurality of wall segments, a first aperture extending through a wall segment and communicating with an ink jet orifice and a second aperture extending through a wall segment and communicating with an ink supply duct. The pressure cha

  5. Balancing device

    NARCIS (Netherlands)

    Van Dorsser, W.D.; Herder, J.L.; Wisse B.M.; Barents, R.

    2007-01-01

    The invention relates to a balancing device for a mass, comprising an arm that is adjustable about a pivoting point and with which the mass is coupled, and an adjustable spring system that is coupled with the arm, which spring system comprises at least one spring, wherein the spring system comprises

  6. The role of complementary and alternative medicine (CAM in Germany – A focus group study of GPs

    Directory of Open Access Journals (Sweden)

    Rosemann Thomas

    2008-06-01

    Full Text Available Abstract Background There has been a marked increase in the use of complementary and alternative medicine (CAM in recent years worldwide. In Germany, apart from 'Heilpraktiker' (= state-licensed, non-medical CAM practitioners, some general practitioners (GPs provide CAM in their practices. This paper aims to explore the attitudes of GPs about the role of CAM in Germany, in relation to the healthcare system, quality of care, medical education and research. Furthermore, experiences of GPs integrating CAM in their daily practice were explored. Methods Using a qualitative methodological approach 3 focus groups with a convenience sample of 17 GPs were conducted. The discussions were transcribed verbatim and analysed using qualitative content analysis. Results The majority of the participating GPs had integrated one or more CAM therapies into their every-day practice. Four key themes were identified based on the topics covered in the focus groups: the role of CAM within the German healthcare system, quality of care, education and research. Within the theme 'role of CAM within the healthcare system' there were five categories: integration of CAM, CAM in the Statutory Health Insurance, modernisation of the Statutory Health Insurance Act, individual healthcare services and 'Heilpraktiker'. Regarding quality of care there were two broad groups of GPs: those who thought patients would benefit from standardizing CAM and those who feared that quality control would interfere with the individual approach of CAM. The main issues identified relating to research and education were the need for the development of alternative research strategies and the low quality of existing CAM education respectively. Conclusion The majority of the participating GPs considered CAM as a reasonable complementary approach within primary care. The study increased our understanding of GPs attitudes about the role of CAM within the German healthcare system and the use of

  7. Is complementary and alternative medicine (CAM cost-effective? a systematic review

    Directory of Open Access Journals (Sweden)

    Caspi Opher

    2005-06-01

    Full Text Available Abstract Background Out-of-pocket expenditures of over $34 billion per year in the US are an apparent testament to a widely held belief that complementary and alternative medicine (CAM therapies have benefits that outweigh their costs. However, regardless of public opinion, there is often little more than anecdotal evidence on the health and economic implications of CAM therapies. The objectives of this study are to present an overview of economic evaluation and to expand upon a previous review to examine the current scope and quality of CAM economic evaluations. Methods The data sources used were Medline, AMED, Alt-HealthWatch, and the Complementary and Alternative Medicine Citation Index; January 1999 to October 2004. Papers that reported original data on specific CAM therapies from any form of standard economic analysis were included. Full economic evaluations were subjected to two types of quality review. The first was a 35-item checklist for reporting quality, and the second was a set of four criteria for study quality (randomization, prospective collection of economic data, comparison to usual care, and no blinding. Results A total of 56 economic evaluations (39 full evaluations of CAM were found covering a range of therapies applied to a variety of conditions. The reporting quality of the full evaluations was poor for certain items, but was comparable to the quality found by systematic reviews of economic evaluations in conventional medicine. Regarding study quality, 14 (36% studies were found to meet all four criteria. These exemplary studies indicate CAM therapies that may be considered cost-effective compared to usual care for various conditions: acupuncture for migraine, manual therapy for neck pain, spa therapy for Parkinson's, self-administered stress management for cancer patients undergoing chemotherapy, pre- and post-operative oral nutritional supplementation for lower gastrointestinal tract surgery, biofeedback for patients with

  8. Design and fabrication of complete dentures using CAD/CAM technology

    Science.gov (United States)

    Han, Weili; Li, Yanfeng; Zhang, Yue; lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    Abstract The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures. The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures. Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures. Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM. PMID:28072686

  9. Management of CAD/CAM information: Key to improved manufacturing productivity

    Science.gov (United States)

    Fulton, R. E.; Brainin, J.

    1984-01-01

    A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/Industry project designated Integrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 repesentatives from aerospace and computer companies. The IPAD accomplishments to date in development of requirements and prototype software for various levels of company-wide CAD/CAM data management are summarized and plans for development of technology for management of distributed CAD/CAM data and information required to control future knowledge-based CAD/CAM systems are discussed.

  10. Design and fabrication of complete dentures using CAD/CAM technology.

    Science.gov (United States)

    Han, Weili; Li, Yanfeng; Zhang, Yue; Lv, Yuan; Zhang, Ying; Hu, Ping; Liu, Huanyue; Ma, Zheng; Shen, Yi

    2017-01-01

    The aim of the study was to test the feasibility of using commercially available computer-aided design and computer-aided manufacturing (CAD/CAM) technology including 3Shape Dental System 2013 trial version, WIELAND V2.0.049 and WIELAND ZENOTEC T1 milling machine to design and fabricate complete dentures.The modeling process of full denture available in the trial version of 3Shape Dental System 2013 was used to design virtual complete dentures on the basis of 3-dimensional (3D) digital edentulous models generated from the physical models. The virtual complete dentures designed were exported to CAM software of WIELAND V2.0.049. A WIELAND ZENOTEC T1 milling machine controlled by the CAM software was used to fabricate physical dentitions and baseplates by milling acrylic resin composite plates. The physical dentitions were bonded to the corresponding baseplates to form the maxillary and mandibular complete dentures.Virtual complete dentures were successfully designed using the software through several steps including generation of 3D digital edentulous models, model analysis, arrangement of artificial teeth, trimming relief area, and occlusal adjustment. Physical dentitions and baseplates were successfully fabricated according to the designed virtual complete dentures using milling machine controlled by a CAM software. Bonding physical dentitions to the corresponding baseplates generated the final physical complete dentures.Our study demonstrated that complete dentures could be successfully designed and fabricated by using CAD/CAM.

  11. ANATOMIC STUDY OF THE PROXIMAL THIRD OF THE FEMUR: FEMOROACETABULAR IMPACT AND THE CAM EFFECT

    Science.gov (United States)

    Labronici, Pedro José; Alves, Sergio Delmonte; da Silva, Anselmo Fernandes; Giuberti, Gilberto Ribeiro; de Azevedo Neto, Justino Nóbrega; Mezzalira Penedo, Jorge Luiz

    2015-01-01

    To analyze anatomical variations of the proximal end of femur that could cause a femoroacetabular impact. Methods: 199 skeletically mature anatomical specimens of femurs were used. The femurs were measured in order to determine the anteversion angle of the femoral neck, neckshaft angle, sphericity of the femoral head at anteroposterior and superoinferior, angle between epiphysis and the anterior femoral neck, angle between epiphysis and the neck at lateral plane, anteroposterior distance at 5mm of the head and neck junction and anteroposterior distance of the neck base. Results: we found that the impact subgroup presented a significantly larger junction diameter of 5mm (p = 0.0001) and cam-head (%) (p= 0.0001), while base-cam (%) (p = 0.0001) showed a significantly smaller diameter than the subgroup without impact. It was identified that cam-head (%) ≤ 80 e base-cam (%) ≤ 73 were identified as the optimal impact points. Conclusion: our study showed that the effect cam, caused by anatomical variations of the proximal femoral end focused the head-neck junction and base of the neck-junction head-neck. These rates can be predictive factors of the impact. PMID:26998462

  12. PreCam: A Precursor Observational Campaign for Calibration of the Dark Energy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, K.; Kuhlmann, S.; Allam, S.; Annis, J. T.; Bailey, T.; Balbinot, E.; Bernstein, J. P.; Biesiadzinski, T.; Burke, D. L.; Butner, M.; Camargo, J. I. B.; da Costa, L. A. N.; DePoy, D.; Diehl, H. T.; Dietrich, J. P.; Estrada, J.; Fausti, A.; Gerke, B.; Guarino, V.; Head, H. H.; Kessler, R.; Lin, H.; Lorenzon, W.; Maia, M. A. G.; Maki, L.; Marshall, J.; Nord, B.; Neilsen, E.; Ogando, R. L. C.; Park, D.; Peoples, J.; Rastawicki, D.; Rheault, J. -P.; Santiago, B.; Schubnell, M.; Seitzer, P.; Smith, J. A.; Spinka, H.; Sypniewski, A.; Tarle, G.; Tucker, D. L.; Walker, A. R.; Wester, W.

    2013-04-01

    PreCam, a precursor observational campaign supporting the Dark Energy Survey (DES), is designed to produce a photometric and astrometric catalog of nearly a hundred thousand standard stars within the DES footprint, while the PreCam instrument also serves as a prototype testbed for the Dark Energy Camera's hardware and software. This catalog represents a potential 100-fold increase in Southern Hemisphere photometric standard stars, and therefore will be an important component in the calibration of the Dark Energy Survey. We provide details on the PreCam instrument's design, construction, and testing, as well as results from a subset of the 51 nights of PreCam survey observations on the University of Michigan Department of Astronomy's Curtis-Schmidt telescope at Cerro Tololo Inter-American Observatory (CTIO). We briefly describe the preliminary data processing pipeline that has been developed for PreCam data and the preliminary results of the instrument performance, as well as astrometry and photometry of a sample of stars previously included in other southern sky surveys.

  13. SenseCam as a rehabilitation tool in a child with anterograde amnesia.

    Science.gov (United States)

    Pauly-Takacs, Katalin; Moulin, Chris J A; Estlin, Edward J

    2011-10-01

    We present the case of a 13-year-old boy, CJ, with profound episodic memory difficulties following the diagnosis of a metastatic intracranial germ cell tumour and subsequent treatment with radiotherapy and chemotherapy. At the core of this study is the first application of SenseCam to a child with severe memory impairment. CJ was taken for a walk while he was wearing SenseCam. This included visiting four different locations. We manipulated the number of locations he could review on SenseCam "films" and then tested recognition memory (forced choice) for both reviewed and non-reviewed locations. We also collected his justifications for the choices he made. Our results indicate that repeated viewings of SenseCam images support the formation of personal semantic memories. Overall our results suggest that the use of SenseCam in memory rehabilitation extends beyond supporting episodic memory and recollection, and supports the feasibility of its use with children who have marked memory difficulties.

  14. Engineering task plan for rotary mode core sampling exhausters CAM high radiation interlock

    Energy Technology Data Exchange (ETDEWEB)

    BOGER, R.M.

    1999-05-19

    The Rotary Mode Core Sampling (RMCS) system is primarily made up of the Rotary Mode Core Sample Trucks (RMCST) and the RMCS Exhausters. During RMCS operations an Exhauster is connected to a tank riser and withdraws gases from the tank dome vapor space at approximately 200 Standard Cubic Feet per Minute (SCFM). The gases are passed through two High Efficiency Particulate Air (HEPA) filters before passing out the exhaust stack to the atmosphere. A Continuous Air Monitor (CAM) monitors the exhaust gases in the exhaust stack for beta particle and gamma radiation. The CAM has a high radiation alarm output and a detector fail alarm output. The CAM alarms are currently connected to the data logger only. The CAM alarms require operator response per procedure LMHC 1998 but no automatic functions are initiated by the CAM alarms. Currently, there are three events that can cause an automatic shut down of the Exhauster. These are, Low Tank Pressure, Highnow Stack Flow and High HEPA Filter Differential Pressure (DP).

  15. Treatment Expectations for CAM Interventions in Pediatric Chronic Pain Patients and their Parents

    Directory of Open Access Journals (Sweden)

    Jennie C. I. Tsao

    2005-01-01

    Full Text Available Patient expectations regarding complementary and alternative medicine (CAM interventions have important implications for treatment adherence, attrition and clinical outcome. Little is known, however, about parent and child treatment expectations regarding CAM approaches for pediatric chronic pain problems. The present study examined ratings of the expected benefits of CAM (i.e. hypnosis, massage, acupuncture, yoga and relaxation and conventional medicine (i.e. medications, surgery interventions in 45 children (32 girls; mean age = 13.8 years ± 2.5 and parents (39 mothers presenting for treatment at a specialty clinic for chronic pediatric pain. Among children, medications and relaxation were expected to be significantly more helpful than the remaining approaches (P < 0.01. However, children expected the three lowest rated interventions, acupuncture, surgery and hypnosis, to be of equal benefit. Results among parents were similar to those found in children but there were fewer significant differences between ratings of the various interventions. Only surgery was expected by parents to be significantly less helpful than the other approaches (P < 0.01. When parent and child perceptions were compared, parents expected hypnosis, acupuncture and yoga, to be more beneficial than did children, whereas children expected surgery to be more helpful than did parents (P < 0.01. Overall, children expected the benefits of CAM to be fairly low with parents' expectations only somewhat more positive. The current findings suggest that educational efforts directed at enhancing treatment expectations regarding CAM, particularly among children with chronic pain, are warranted.

  16. Tilting double-prism scanner driven by cam-based mechanism.

    Science.gov (United States)

    Li, Anhu; Yi, Wanli; Sun, Wansong; Liu, Liren

    2015-06-20

    A pair of orthogonal tilting prisms has been explored in our previous work to perform the orientation and position tracking function with tracking accuracy better than submicroradian order. Crucial to the function implementation, however, is the real-time nonlinear control of the tilting angles of double prisms for tracking a given target trajectory. In previous papers [Proc. SPIE5892, 1-5 (2005).PSISDG0277-786X; Appl. Opt.45, 8063 (2006).PSISDG0277-786X; Proc. SPIE6709, 41 (2007).PSISDG0277-786X; Appl. Opt.51, 356 (2011).10.1364/AO.51.000356APOPAI1559-128X; Appl. Opt.53, 3712 (2014).10.1364/AO.53.003712APOPAI1559-128X], a new driving method by a cam-based mechanism, which can transfer the control problem to the design of corresponding cam configuration, is investigated. The design process of a cam-based mechanism is explained from the mapping relation between the tilting angles of a prism and the configuration curve of a corresponding cam. Based on the designed cam-based mechanism, a tracking error less than 0.375% is depicted between the tracking trajectory and the original one. Moreover, the dynamic characteristic of the tracking mechanism is discussed in detail as well as the impacts of different tilting speeds on the tracking trajectory. The proposed tracking mechanism of a tilting double-prism scanner can create a new avenue for passively tracking a given target.

  17. TROP-1/Ep-CAM and CD24 are potential candidates for ovarian cancer therapy.

    Science.gov (United States)

    Wang, Guihong; Zhang, Zhenhua; Ren, Yongqiang

    2015-01-01

    To clarify the possible roles of epithelial cell adhesion molecule (TROP-1/Ep-CAM) and CD24 molecule (CD24) in ovarian tumorigenesis, and explore the possible mechanism underlying this disease. Recombinant eukaryotic expression vectors pCIneo-TROP-1/Ep-CAM and pCIneo-CD24 were transfected into human normal ovarian surface epithelia cell line IOSE-80 respectively, with IOSE-80 cells transfected with the empty vector pCIneo as control. MRNA and protein expression of TROP-1/Ep-CAM and CD24 were detected by RT-PCR and Western blotting, respectively. Cell migration was assayed by trans-well inserts; cell proliferation and adhesion were analyzed by CCK-8 Cell Counting kit; cell cycle and cell apoptosis analysis were performed by flow cytometer. The expressions of TROP-1/Ep-CAM and CD24 were obviously up-regulated in TROP-1/Ep-CAM group and CD24 group compared to that in control group (PCAM group and CD24 group was significantly promoted migratory and proliferation abilities, but inhibited cell apoptosis and adhesive than that of control group (PCAM and CD24 may play key roles in the progression of ovarian cancer through promoting migration, proliferation, inhibiting cell apoptosis and adhesion, and disturbing cell cycle. They may be used as specific therapeutic targets in the treatment of ovarian cancer. However, further experiments are still needed to confirm our results.

  18. Expression of EpCam and Villin in Barrett’s Esophagus and in Gastric Cardia

    Directory of Open Access Journals (Sweden)

    Mario Anders

    2008-01-01

    Full Text Available In the current study we aimed to clarify the potential of EpCAM and villin as in vivo biomarkers for both Barrett esophagus (BE-associated neoplasia and BE versus cardiac mucosa. Immunohistochemical staining in BE with various degrees of intraepithelial neoplasia (IN, Barrett carcinoma (BC and in normal cardiac mucosa (CM revealed a lack of EpCam and villin in squamous esophageal epithelium. All specimens of IN and BC showed EpCam with varying staining intensities. In 57% of CM samples a weak signal was detected; the remainder displayed strong EpCam expression. Villin was found in 97% of BE specimens and in all those with IN; 37% of BC and 75% of CM specimens were also positive. We conclude that expression of EpCam and villin differs only between squamous epithelium and BE. Determination of these proteins does not allow discrimination between different degrees of neoplasia or between esophageal intestinal metaplasia and cardiac mucosa.

  19. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  20. Magnetohydrodynamic device

    Energy Technology Data Exchange (ETDEWEB)

    Gorlin, S.M.; Ljubimov, G.A.; Bitjurin, V.A.; Kovbasjuk, V.I.; Maximenko, V.I.; Medin, S.A.; Barshak, A.E.

    1979-12-25

    A magnetohydrodynamic device having a duct for a conducting gas to flow at an angle with the direction of the magnetic field induction vector is described. The duct is situated in the magnetic system and is provided with a plurality of electrodes adapted to interact electrically with the gas, whereas the cross-sectional shape of the duct working space is bounded by a closed contour formed by a curve inscribed into a rectangle. 1 claim.

  1. Soil Diversity and Hydration as Observed by ChemCam at Gale Crater, Mars

    Science.gov (United States)

    Meslin, P.-Y.; Gasnault, O.; Forni, O.; Schröder, S.; Cousin, A.; Berger, G.; Clegg, S. M.; Lasue, J.; Maurice, S.; Sautter, V.; Le Mouélic, S.; Wiens, R. C.; Fabre, C.; Goetz, W.; Bish, D.; Mangold, N.; Ehlmann, B.; Lanza, N.; Harri, A.-M.; Anderson, R.; Rampe, E.; McConnochie, T. H.; Pinet, P.; Blaney, D.; Léveillé, R.; Archer, D.; Barraclough, B.; Bender, S.; Blake, D.; Blank, J. G.; Bridges, N.; Clark, B. C.; DeFlores, L.; Delapp, D.; Dromart, G.; Dyar, M. D.; Fisk, M.; Gondet, B.; Grotzinger, J.; Herkenhoff, K.; Johnson, J.; Lacour, J.-L.; Langevin, Y.; Leshin, L.; Lewin, E.; Madsen, M. B.; Melikechi, N.; Mezzacappa, A.; Mischna, M. A.; Moores, J. E.; Newsom, H.; Ollila, A.; Perez, R.; Renno, N.; Sirven, J.-B.; Tokar, R.; de la Torre, M.; d'Uston, L.; Vaniman, D.; Yingst, A.; Kemppinen, Osku; Minitti, Michelle; Cremers, David; Bell, James F.; Edgar, Lauren; Farmer, Jack; Godber, Austin; Wadhwa, Meenakshi; Wellington, Danika; McEwan, Ian; Newman, Claire; Richardson, Mark; Charpentier, Antoine; Peret, Laurent; King, Penelope; Weigle, Gerald; Schmidt, Mariek; Li, Shuai; Milliken, Ralph; Robertson, Kevin; Sun, Vivian; Baker, Michael; Edwards, Christopher; Farley, Kenneth; Griffes, Jennifer; Miller, Hayden; Newcombe, Megan; Pilorget, Cedric; Rice, Melissa; Siebach, Kirsten; Stack, Katie; Stolper, Edward; Brunet, Claude; Hipkin, Victoria; Marchand, Geneviève; Sánchez, Pablo Sobrón; Favot, Laurent; Cody, George; Steele, Andrew; Flückiger, Lorenzo; Lees, David; Nefian, Ara; Martin, Mildred; Gailhanou, Marc; Westall, Frances; Israël, Guy; Agard, Christophe; Baroukh, Julien; Donny, Christophe; Gaboriaud, Alain; Guillemot, Philippe; Lafaille, Vivian; Lorigny, Eric; Paillet, Alexis; Pérez, René; Saccoccio, Muriel; Yana, Charles; Armiens-Aparicio, Carlos; Rodríguez, Javier Caride; Blázquez, Isaías Carrasco; Gómez, Felipe Gómez; Gómez-Elvira, Javier; Hettrich, Sebastian; Malvitte, Alain Lepinette; Jiménez, Mercedes Marín; Martínez-Frías, Jesús; Martín-Soler, Javier; Martín-Torres, F. Javier; Jurado, Antonio Molina; Mora-Sotomayor, Luis; Caro, Guillermo Muñoz; López, Sara Navarro; Peinado-González, Verónica; Pla-García, Jorge; Manfredi, José Antonio Rodriguez; Romeral-Planelló, Julio José; Fuentes, Sara Alejandra Sans; Martinez, Eduardo Sebastian; Redondo, Josefina Torres; Urqui-O'Callaghan, Roser; Mier, María-Paz Zorzano; Chipera, Steve; Mauchien, Patrick; Manning, Heidi; Fairén, Alberto; Hayes, Alexander; Joseph, Jonathan; Squyres, Steven; Sullivan, Robert; Thomas, Peter; Dupont, Audrey; Lundberg, Angela; DeMarines, Julia; Grinspoon, David; Reitz, Günther; Prats, Benito; Atlaskin, Evgeny; Genzer, Maria; Haukka, Harri; Kahanpää, Henrik; Kauhanen, Janne; Kemppinen, Osku; Paton, Mark; Polkko, Jouni; Schmidt, Walter; Siili, Tero; Wray, James; Wilhelm, Mary Beth; Poitrasson, Franck; Patel, Kiran; Gorevan, Stephen; Indyk, Stephen; Paulsen, Gale; Gupta, Sanjeev; Schieber, Juergen; Geffroy, Claude; Baratoux, David; Cros, Alain; Lee, Qiu-Mei; Pallier, Etienne; Parot, Yann; Toplis, Mike; Brunner, Will; Heydari, Ezat; Achilles, Cherie; Oehler, Dorothy; Sutter, Brad; Cabane, Michel; Coscia, David; Israël, Guy; Szopa, Cyril; Robert, François; Nachon, Marion; Buch, Arnaud; Stalport, Fabien; Coll, Patrice; François, Pascaline; Raulin, François; Teinturier, Samuel; Cameron, James; Dingler, Robert; Jackson, Ryan Steele; Johnstone, Stephen; Little, Cynthia; Nelson, Tony; Williams, Richard B.; Jones, Andrea; Kirkland, Laurel; Treiman, Allan; Baker, Burt; Cantor, Bruce; Caplinger, Michael; Davis, Scott; Duston, Brian; Edgett, Kenneth; Fay, Donald; Hardgrove, Craig; Harker, David; Herrera, Paul; Jensen, Elsa; Kennedy, Megan R.; Krezoski, Gillian; Krysak, Daniel; Lipkaman, Leslie; Malin, Michael; McCartney, Elaina; McNair, Sean; Nixon, Brian; Posiolova, Liliya; Ravine, Michael; Salamon, Andrew; Saper, Lee; Stoiber, Kevin; Supulver, Kimberley; Van Beek, Jason; Van Beek, Tessa; Zimdar, Robert; French, Katherine Louise; Iagnemma, Karl; Miller, Kristen; Summons, Roger; Goesmann, Fred; Hviid, Stubbe; Johnson, Micah; Lefavor, Matthew; Lyness, Eric; Breves, Elly; Fassett, Caleb; Bristow, Thomas; DesMarais, David; Edwards, Laurence; Haberle, Robert; Hoehler, Tori; Hollingsworth, Jeff; Kahre, Melinda; Keely, Leslie; McKay, Christopher; Wilhelm, Mary Beth; Bleacher, Lora; Brinckerhoff, William; Choi, David; Conrad, Pamela; Dworkin, Jason P.; Eigenbrode, Jennifer; Floyd, Melissa; Freissinet, Caroline; Garvin, James; Glavin, Daniel; Harpold, Daniel; Jones, Andrea; Mahaffy, Paul; Martin, David K.; McAdam, Amy; Pavlov, Alexander; Raaen, Eric; Smith, Michael D.; Stern, Jennifer; Tan, Florence; Trainer, Melissa; Meyer, Michael; Posner, Arik; Voytek, Mary; Anderson, Robert C.; Aubrey, Andrew; Beegle, Luther W.; Behar, Alberto; Brinza, David; Calef, Fred; Christensen, Lance; Crisp, Joy A.; Feldman, Jason; Feldman, Sabrina; Flesch, Gregory; Hurowitz, Joel; Jun, Insoo; Keymeulen, Didier; Maki, Justin; Morookian, John Michael; Parker, Timothy; Pavri, Betina; Schoppers, Marcel; Sengstacken, Aaron; Simmonds, John J.; Spanovich, Nicole; Vasavada, Ashwin R.; Webster, Christopher R.; Yen, Albert; Cucinotta, Francis; Jones, John H.; Ming, Douglas; Morris, Richard V.; Niles, Paul; Nolan, Thomas; Radziemski, Leon; Berman, Daniel; Dobrea, Eldar Noe; Williams, Rebecca M. E.; Lewis, Kevin; Cleghorn, Timothy; Huntress, Wesley; Manhès, Gérard; Hudgins, Judy; Olson, Timothy; Stewart, Noel; Sarrazin, Philippe; Grant, John; Vicenzi, Edward; Wilson, Sharon A.; Bullock, Mark; Ehresmann, Bent; Hamilton, Victoria; Hassler, Donald; Peterson, Joseph; Rafkin, Scot; Zeitlin, Cary; Fedosov, Fedor; Golovin, Dmitry; Karpushkina, Natalya; Kozyrev, Alexander; Litvak, Maxim; Malakhov, Alexey; Mitrofanov, Igor; Mokrousov, Maxim; Nikiforov, Sergey; Prokhorov, Vasily; Sanin, Anton; Tretyakov, Vladislav; Varenikov, Alexey; Vostrukhin, Andrey; Kuzmin, Ruslan; Wolff, Michael; McLennan, Scott; Botta, Oliver; Drake, Darrell; Bean, Keri; Lemmon, Mark; Schwenzer, Susanne P.; Lee, Ella Mae; Sucharski, Robert; Hernández, Miguel Ángel de Pablo; Ávalos, Juan José Blanco; Ramos, Miguel; Kim, Myung-Hee; Malespin, Charles; Plante, Ianik; Muller, Jan-Peter; Navarro-González, Rafael; Ewing, Ryan; Boynton, William; Downs, Robert; Fitzgibbon, Mike; Harshman, Karl; Morrison, Shaunna; Dietrich, William; Kortmann, Onno; Palucis, Marisa; Sumner, Dawn Y.; Williams, Amy; Lugmair, Günter; Wilson, Michael A.; Rubin, David; Jakosky, Bruce; Balic-Zunic, Tonci; Frydenvang, Jens; Jensen, Jaqueline Kløvgaard; Kinch, Kjartan; Koefoed, Asmus; Stipp, Susan Louise Svane; Boyd, Nick; Campbell, John L.; Gellert, Ralf; Perrett, Glynis; Pradler, Irina; VanBommel, Scott; Jacob, Samantha; Owen, Tobias; Rowland, Scott; Atlaskin, Evgeny; Savijärvi, Hannu; Boehm, Eckart; Böttcher, Stephan; Burmeister, Sönke; Guo, Jingnan; Köhler, Jan; García, César Martín; Mueller-Mellin, Reinhold; Wimmer-Schweingruber, Robert; Bridges, John C.; Benna, Mehdi; Franz, Heather; Bower, Hannah; Brunner, Anna; Blau, Hannah; Boucher, Thomas; Carmosino, Marco; Atreya, Sushil; Elliott, Harvey; Halleaux, Douglas; Rennó, Nilton; Wong, Michael; Pepin, Robert; Elliott, Beverley; Spray, John; Thompson, Lucy; Gordon, Suzanne; Williams, Joshua; Vasconcelos, Paulo; Bentz, Jennifer; Nealson, Kenneth; Popa, Radu; Kah, Linda C.; Moersch, Jeffrey; Tate, Christopher; Day, Mackenzie; Kocurek, Gary; Hallet, Bernard; Sletten, Ronald; Francis, Raymond; McCullough, Emily; Cloutis, Ed; ten Kate, Inge Loes; Kuzmin, Ruslan; Arvidson, Raymond; Fraeman, Abigail; Scholes, Daniel; Slavney, Susan; Stein, Thomas; Ward, Jennifer; Berger, Jeffrey

    2013-09-01

    The ChemCam instrument, which provides insight into martian soil chemistry at the submillimeter scale, identified two principal soil types along the Curiosity rover traverse: a fine-grained mafic type and a locally derived, coarse-grained felsic type. The mafic soil component is representative of widespread martian soils and is similar in composition to the martian dust. It possesses a ubiquitous hydrogen signature in ChemCam spectra, corresponding to the hydration of the amorphous phases found in the soil by the CheMin instrument. This hydration likely accounts for an important fraction of the global hydration of the surface seen by previous orbital measurements. ChemCam analyses did not reveal any significant exchange of water vapor between the regolith and the atmosphere. These observations provide constraints on the nature of the amorphous phases and their hydration.

  2. Design Alteration of Motor-Cycle Engine Cam for Pneumatic Operation

    Directory of Open Access Journals (Sweden)

    Jimil M. Shah

    2013-06-01

    Full Text Available Power produced by pressurized gases/air has been used in many applications since decades. The power produced by that means is pollution free too. Hence substitution of petrol/diesel in engines with compressed air will be a step towards pollution free engine. The 4-stroke IC engine is to be converted into a 2-stroke pneumatic engine. Various design changes in camshaft design were carried out. The valve timing diagram was derived for the same. The cam profile of a double lobed cam as required in the valve timing diagram was designed in Pro-e software and was cut on a wire cut machine. The cam and camshaft were manufactured separately and then assembled.

  3. Soil diversity and hydration as observed by ChemCam at Gale crater, Mars.

    Science.gov (United States)

    Meslin, P-Y; Gasnault, O; Forni, O; Schröder, S; Cousin, A; Berger, G; Clegg, S M; Lasue, J; Maurice, S; Sautter, V; Le Mouélic, S; Wiens, R C; Fabre, C; Goetz, W; Bish, D; Mangold, N; Ehlmann, B; Lanza, N; Harri, A-M; Anderson, R; Rampe, E; McConnochie, T H; Pinet, P; Blaney, D; Léveillé, R; Archer, D; Barraclough, B; Bender, S; Blake, D; Blank, J G; Bridges, N; Clark, B C; DeFlores, L; Delapp, D; Dromart, G; Dyar, M D; Fisk, M; Gondet, B; Grotzinger, J; Herkenhoff, K; Johnson, J; Lacour, J-L; Langevin, Y; Leshin, L; Lewin, E; Madsen, M B; Melikechi, N; Mezzacappa, A; Mischna, M A; Moores, J E; Newsom, H; Ollila, A; Perez, R; Renno, N; Sirven, J-B; Tokar, R; de la Torre, M; d'Uston, L; Vaniman, D; Yingst, A

    2013-09-27

    The ChemCam instrument, which provides insight into martian soil chemistry at the submillimeter scale, identified two principal soil types along the Curiosity rover traverse: a fine-grained mafic type and a locally derived, coarse-grained felsic type. The mafic soil component is representative of widespread martian soils and is similar in composition to the martian dust. It possesses a ubiquitous hydrogen signature in ChemCam spectra, corresponding to the hydration of the amorphous phases found in the soil by the CheMin instrument. This hydration likely accounts for an important fraction of the global hydration of the surface seen by previous orbital measurements. ChemCam analyses did not reveal any significant exchange of water vapor between the regolith and the atmosphere. These observations provide constraints on the nature of the amorphous phases and their hydration.

  4. Cooling Tests of the NectarCAM camera for the Cherenkov Telescope Array

    CERN Document Server

    Moulin, E; Durand, D; Feirreira, O; Fesquet, M; Giebels, B; Glicenstein, J -F; Loiseau, D; Louis, F; Nunio, F; Rateau, S; consortia, CTA

    2015-01-01

    The NectarCAM is a camera proposed for the medium-sized telescopes in the framework of the Cherenkov Telescope Array (CTA), the next-generation observatory for very-high-energy gamma-ray astronomy. The cameras are designed to operate in an open environment and their mechanics must provide protection for all their components under the conditions defined for the CTA observatory. In order to operate in a stable environment and ensure the best physics performance, each NectarCAM will be enclosed in a slightly overpressurized, nearly air-tight, camera body, to prevent dust and water from entering. The total power dissipation will be ~7.7 kW for a 1855-pixel camera. The largest fraction is dissipated by the readout electronics in the modules. We present the design and implementation of the cooling system together with the test bench results obtained on the NectarCAM thermal demonstrator.

  5. A New Method to Design Cam Used in Automobile Heating, Ventilating and Cooling System

    Science.gov (United States)

    Singh, B.; Singh, D.; Saini, J. S.

    2012-10-01

    With the automotive air-conditioning industry aiming at better levels of quality, cost effectiveness and short time to market, the need for simulation is at an all time high. In the present study, the airflow control mechanism of an automotive heating, ventilating and cooling module for opening various doors/dampers were kinematically analyzed. A new method for cam design was developed which is faster and simpler than the existing oscillating link method. The existing design was modified for the same output using the new cam design method. It is shown that the torque required in the modified design is lesser than that in the existing design, thus lowering the effort required to rotate the cam from the control panel.

  6. DEVELOPMENT OF TRANSMISSION QUALITY CONTROL CHARTS FOR SINGLE ROLLER- TO- CAM INTERMITTENT MOTION MECHANISMS

    Directory of Open Access Journals (Sweden)

    DR. K. S. TRIPATHI

    2010-10-01

    Full Text Available This paper addresses itself to a portion of a systematic investigation of a very simple intermittent motion mechanism consisting of a single roller crank and a single cam. The mechanism presented in this paper, being continuous contact type, does not have dynamic problems such as sudden jerk experienced in traditional genevamechanism. The cam being the output and the cam radius being a varying quantity, the conventional transmission angle cannot be used. A new rational transmission index is introduced in the present nvestigation. Here transmission index charts are developed as design aids in synthesizing a law of motion ( in general and not just forintermittent motion mechanisms . The variation of transmission index along the motion law curve may be readily seen by superimposing the chosen motion law on the transmission index chart. Appropriate changes may then be made in the motion law as found necessary.

  7. Millora del camí que uneix Can Tintorer amb Molins de Rei

    OpenAIRE

    Canalias Suquet, Ignasi

    2013-01-01

    El projecte té com a finalitat la millora del camí que uneix la població de Molins de Rei amb el restaurant de Can Tintorer. Aquest camí forma part del parc natural de Collserola i és molt utilitzat per accedir amb cotxe fins al restaurant i a l’hípica del Bosc que hi ha al costat seu; com també per molts usuaris del parc natural ja sigui per passejar-hi a peu, bicicleta o cavall. L’objectiu del projecte és donar solució als problemes que presenta el camí com són passos estrets pe...

  8. Overview to the two-part series: Measurement equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS® short forms

    Directory of Open Access Journals (Sweden)

    Bryce B. Reeve

    2016-03-01

    Full Text Available Measurement equivalence across differing socio-demographic groups is essential for valid assessment. This is one of two issues of Psychological Test and Assessment Modeling that contains articles describing methods and substantive findings related to establishing measurement equivalence in self-reported health, mental health and social functioning measures. The articles in this two part series describe analyses of items assessing eight domains: fatigue, depression, anxiety, sleep, pain, physical function, cognitive concerns and social function. Additionally, two overview articles describe the methods and sample characteristics of the data set used in these analyses. An additional article describes the important topic of assessing magnitude and impact of differential item functioning. These articles provide the first strong evidence supporting the measurement equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS® short form measures in ethnically, socio-demographically diverse groups, and is a beginning step in meeting the international call for further study of their performance in such groups.

  9. Sandblasting may damage the surface of composite CAD-CAM blocks.

    Science.gov (United States)

    Yoshihara, Kumiko; Nagaoka, Noriyuki; Maruo, Yukinori; Nishigawa, Goro; Irie, Masao; Yoshida, Yasuhiro; Van Meerbeek, Bart

    2017-03-01

    CAD-CAM blocks to fabricate semi-direct and indirect restorations are available in different sorts of ceramics as well as composite. In order to bond restorations prepared out of composite blocks into tooth cavities, it is recommended to gently sandblast the surface prior to the application of a primer/adhesive. Today, the effect of sandblasting composite block surfaces has not thoroughly been investigated. In this study, the ultra-structure of composite CAD-CAM blocks was investigated with special attention to the effect of sandblasting on the surface topography and of silanization on the bonding performance. Five different composite CAD-CAM blocks were involved. We correlatively investigated their structural and chemical composition using X-ray diffraction (XRD), energy dispersion spectroscopy (EDS), scanning electron microscopy (SEM) and (scanning) transmission electron microscopy ((S)TEM). The effect of sandblasting was also imaged in cross-section and at the interface with composite cement. Finally, we measured the shear bond strength to the sandblasted block surface with and without silanization. All composite blocks revealed a different ultra-structure. Sandblasting increased surface roughness and resulted in an irregular surface with some filler exposure. Sandblasting also damaged the surface. When the sandblasted composite blocks were silanized, superior bonding receptiveness in terms of higher bond strength was achieved except for Shofu Block HC. Sandblasting followed by silanization improved the bond strength to composite CAD-CAM blocks. However, sandblasting may also damage the composite CAD-CAM block surface. For the composite CAD-CAM block Shofu Block HC, the damage was so severe that silanization did not improve bond strength. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. Survey on the use of CAD-CAM technology by UK and Irish dental technicians.

    Science.gov (United States)

    Blackwell, E; Nesbit, M; Petridis, H

    2017-05-12

    Statement of the problem Digital workflows (CAD/CAM) have been introduced in dentistry during recent years. No published information exists on dental technicians' use and reporting of this technology.Purpose The aim of this cross sectional survey was to identify the extent digital technology has infiltrated the workplace and to investigate the factors affecting the use of CAD-CAM technology by dental laboratory technicians within Ireland and the UK.Materials and methods A web-based questionnaire was composed (Opinio, Object Planet Inc. Oslo, Norway) and distributed to UK and Irish dental technicians. Answers to all questions were anonymous and grouped such that general information was gathered initially, followed by branching of the survey into two sections depending on whether or not the respondent worked with CAD-CAM technology. Results were compiled and statistical analysis (Fisher's Exact test, SPSS, IBM, Armonk, New York, USA) was performed in order to investigate any correlation between various demographic variables and the answers provided.Results The survey was distributed to 760 UK technicians and 77 Irish technicians. The total number of completed surveys was 105, which yielded a total response rate of 14%. Most technicians reported using some form of CAD/CAM aspect in the workflow, and this was more significant for technicians working in large laboratories. Most training received was company-led. Large laboratories were also significantly correlated with less outsourcing of CAD/CAM work and a change in dental material use leading to the increase of zirconia and the decrease of noble alloys. Dental technicians did not report any significant change in working relationships and staffing as a result of CAD/CAM incorporation. High initial investment cost was the most common reason quoted from non-users, along with the lack of such technology in their working environment.

  11. CAM and Cell Fate Targeting: Molecular and Energetic Insights into Cell Growth and Differentiation

    Directory of Open Access Journals (Sweden)

    Carlo Ventura

    2005-01-01

    Full Text Available Evidence-based medicine is switching from the analysis of single diseases at a time toward an integrated assessment of a diseased person. Complementary and alternative medicine (CAM offers multiple holistic approaches, including osteopathy, homeopathy, chiropractic, acupuncture, herbal and energy medicine and meditation, all potentially impacting on major human diseases. It is now becoming evident that acupuncture can modify the expression of different endorphin genes and the expression of genes encoding for crucial transcription factors in cellular homeostasis. Extremely low frequency magnetic fields have been found to prime the commitment to a myocardial lineage in mouse embryonic stem cells, suggesting that magnetic energy may direct stem cell differentiation into specific cellular phenotypes without the aid of gene transfer technologies. This finding may pave the way to novel approaches in tissue engineering and regeneration. Different ginseng extracts have been shown to modulate growth and differentiation in pluripotent cells and to exert wound-healing and antitumor effects through opposing activities on the vascular system, prompting the hypothesis that ancient compounds may be the target for new logics in cell therapy. These observations and the subtle entanglement among different CAM systems suggest that CAM modalities may deeply affect both the signaling and transcriptional level of cellular homeostasis. Such a perception holds promises for a new era in CAM, prompting reproducible documentation of biological responses to CAM-related strategies and compounds. To this end, functional genomics and proteomics and the comprehension of the cell signaling networks may substantially contribute to the development of a molecular evidence–based CAM.

  12. Management of CAD/CAM information: Key to improved manufacturing productivity

    Science.gov (United States)

    Fulton, R. E.; Brainin, J.

    1984-01-01

    A key element to improved industry productivity is effective management of CAD/CAM information. To stimulate advancements in this area, a joint NASA/Navy/industry project designated Intergrated Programs for Aerospace-Vehicle Design (IPAD) is underway with the goal of raising aerospace industry productivity through advancement of technology to integrate and manage information involved in the design and manufacturing process. The project complements traditional NASA/DOD research to develop aerospace design technology and the Air Force's Integrated Computer-Aided Manufacturing (ICAM) program to advance CAM technology. IPAD research is guided by an Industry Technical Advisory Board (ITAB) composed of over 100 representatives from aerospace and computer companies.

  13. DISEÑO E IMPLEMENTACIÓN DE UN LABORATORIO DE CAD/CAM

    OpenAIRE

    Rojas Lazo, Oswaldo; Ingeniero industrial de la UNMSM.

    2014-01-01

    El diseño y fabricación asistida con computadora comúnmente denominado CAD/CAM (Computer Aided Desing / Computer Aided Manufacturing) es una tecnología indispensable en los procesos productivos que se encuentran sometidos al alto nivel de competitividad en el mercado nacional e internacional, debido fundamentalmente a que las compañías necesitan abatir sus tiempos de diseño y manufactura con altos niveles de calidad. Design and Computer Aided Manufacturing commonly called CAD / CAM ...

  14. Calibrating the ChemCam LIBS for Carbonate Minerals on Mars

    Science.gov (United States)

    Wiens, Roger C.; Clegg, Samuel M.; Ollila, Ann M.; Barefield, James E.; Lanza, Nina; Newsom, Horton E.

    2009-01-01

    The ChemCam instrument suite on board the NASA Mars Science Laboratory (MSL) rover includes the first LIBS instrument for extraterrestrial applications. Here we examine carbonate minerals in a simulated martian environment using the LIDS technique in order to better understand the in situ signature of these materials on Mars. Both chemical composition and rock type are determined using multivariate analysis (MVA) techniques. Composition is confirmed using scanning electron microscopy (SEM) techniques. Our initial results suggest that ChemCam can recognize and differentiate between carbonate materials on Mars.

  15. 28th International Conference on CAD/CAM, Robotics and Factories of the Future

    CERN Document Server

    Syan, Chanan

    2016-01-01

    This volume is based on the proceedings of the 28th International Conference on CAD/CAM, Robotics and Factories of the Future. This book specially focuses on the positive changes made in the field of robotics, CAD/CAM and future outlook for emerging manufacturing units. Some of the important topics discussed in the conference are product development and sustainability, modeling and simulation, automation, robotics and handling systems, supply chain management and logistics, advanced manufacturing processes, human aspects in engineering activities, emerging scenarios in engineering education and training. The contents of this set of proceedings will prove useful to both researchers and practitioners.

  16. Mathematical model of the Beta Rand Cam{trademark} engine vane seals

    Energy Technology Data Exchange (ETDEWEB)

    Braden, C.H.; Thompson, G.J.; Smith, J.E.; Mucino, V.H. [West Virginia Univ., Morgantown, WV (United States)

    1996-12-31

    A mathematical model of the vane sealing mechanism is presented to determine how the loading on the seals will affect the performance of the Rand Cam{trademark} engine. Within the Rand Cam{trademark} engine, sacrificial linear seals in the vane are used as the main sealing mechanism to prevent blowby from one chamber to the next. Throughout this investigation a kinetostatic analysis, based upon Yamamoto`s Wankel apex seal analysis, is extended into three dimensions. The input data to the model can be varied to study the effects of seal dimensions, seal material, seal dynamics, and friction.

  17. Calibrating the ChemCam LIBS for carbonate minerals on Mars

    Energy Technology Data Exchange (ETDEWEB)

    Wiens, Roger C [Los Alamos National Laboratory; Clegg, Samuel M [Los Alamos National Laboratory; Ollila, Ann M [Los Alamos National Laboratory; Barefield, James E [Los Alamos National Laboratory; Lanza, Nina [Los Alamos National Laboratory; Newsom, Horton E [Los Alamos National Laboratory

    2009-01-01

    The ChemCam instrument suite on board the NASA Mars Science Laboratory (MSL) rover includes the first LIBS instrument for extraterrestrial applications. Here we examine carbonate minerals in a simulated martian environment using the LIDS technique in order to better understand the in situ signature of these materials on Mars. Both chemical composition and rock type are determined using multivariate analysis (MVA) techniques. Composition is confirmed using scanning electron microscopy (SEM) techniques. Our initial results suggest that ChemCam can recognize and differentiate between carbonate materials on Mars.

  18. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.

    Science.gov (United States)

    Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart

    To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p CAD (p = 0.0115), and Lava Ultimate (p CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of adhesive failures was higher for CAD/CAM materials with higher flexural strength (Celtra Duo, IPS e.max CAD, and Lava Ultimate). The bond strength of luting composites to novel CAD/CAM materials is influenced by surface treatment. For each luting composite, an adhesive cementation protocol can be specified in order to obtain the highest bond to the

  19. Research of Multi-axis NC Machining Method of Cylindrical Cam Based on UG NX

    Directory of Open Access Journals (Sweden)

    Liang Qianhua

    2017-01-01

    Full Text Available We have focused significant efforts on developing solutions for precision machining of cylindrical cams based on UG NX. A variety of processing method are put forward according to the digital model for a cylindrical cam which has been derived through parametric design, all of which are made a detailed comparison, analysis, research, elaborated. Simulation processing, post processing and NC program are carried out though optimized processing scheme. It will provide a reference for the numerical control programming of four-Coordinated axis.

  20. Chick ex ovo culture and ex ovo CAM assay: how it really works.

    Science.gov (United States)

    Dohle, Daniel S; Pasa, Susanne D; Gustmann, Sebastian; Laub, Markus; Wissler, Josef H; Jennissen, Herbert P; Dünker, Nicole

    2009-11-30

    Chicken eggs in the early phase of breeding are between in vitro and in vivo systems and provide a vascular test environment not only to study angiogenesis but also to study tumorigenesis. After the chick chorioallantoic membrane (CAM) has developed, its blood vessel network can be easily accessed, manipulated and observed and therefore provides an optimal setting for angiogenesis assays. Since the lymphoid system is not fully developed until late stages of incubation, the chick embryo serves as a naturally immunodeficient host capable of sustaining grafted tissues and cells without species-specific restrictions. In addition to nurturing developing allo- and xenografts, the CAM blood vessel network provides a uniquely supportive environment for tumor cell intravasation, dissemination, and vascular arrest and a repository where arrested cells extravasate to form micro metastatic foci. For experimental purposes, in most of the recent studies the CAM was exposed by cutting a window through the egg shell and experiments were carried out in ovo, resulting in significant limitations in the accessibility of the CAM and possibilities for observation and photo documentation of effects. When shell-less cultures of the chick embryo were used(1-4), no experimental details were provided and, if published at all, the survival rates of these cultures were low. We refined the method of ex ovo culture of chick embryos significantly by introducing a rationally controlled extrusion of the egg content. These ex ovo cultures enhance the accessibility of the CAM and chick embryo, enabling easy in vivo documentation of effects and facilitating experimental manipulation of the embryo. This allows the successful application to a large number of scientific questions: (1) As an improved angiogenesis assay(5,6), (2) an experimental set up for facilitated injections in the vitreous of the chick embryo eye(7-9), (3) as a test environment for dissemination and intravasation of dispersed tumor

  1. Calcium Sulfate Characterized by ChemCam/Curiosity at Gale Crater, Mars

    Science.gov (United States)

    Nachon, M.; Clegg, S. N.; Mangold, N.; Schroeder, S.; Kah, L. C.; Dromart, G.; Ollila, A.; Johnson, J. R.; Oehler, D. Z.; Bridges, J. C.; LeMouelic, S.; Forni, O.; Wiens, R. C.; Rapin, W.; Anderson, R. B.; Blaney, D. L.; Bell, J. F. , III; Clark, B.; Cousin, A.; Dyar, M. D.; Ehlmann, B.; Fabre, C.; Gasnault, O.; Grotzinger, J.; Lasue, J.; Lewin, E.; Leveille, R.; McLennan, S.; Maurice, S.; Meslin, P.-Y.; Rice, M.; Squyres, S. W.; Stack, K.; Sumner, D. Y.; Vaniman, D.; Wellington, D.

    2014-01-01

    Onboard the Mars Science Laboratory (MSL) Curiosity rover, the ChemCam instrument consists of :(1) a Laser-Induced Breakdown Spectrometer (LIBS) for elemental analysis of the targets [1;2] and (2) a Remote Micro Imager (RMI), for the imaging context of laser analysis [3]. Within the Gale crater, Curiosity traveled from Bradbury Landing through the Rocknest region and into Yellowknife Bay (YB). In the latter, abundant light-toned fracture-fill material were seen [4;5]. ChemCam analysis demonstrate that those fracture fills consist of calcium sulfates [6].

  2. Fabricating complete dentures with CAD/CAM technology.

    Science.gov (United States)

    Infante, Luis; Yilmaz, Burak; McGlumphy, Edwin; Finger, Israel

    2014-05-01

    Conventional complete denture prosthetics require several appointments to register the maxillomandibular relationship and evaluate the esthetics. The fabrication of milled complete dental prostheses with digital scanning technology may decrease the number of appointments. The step-by-step method necessary to obtain impressions, maxillomandibular relation records, and anterior tooth position with an anatomic measuring device is described. The technique allows the generation of a virtual denture, which is milled to exact specifications without the use of conventional stone casts, flasking, or processing techniques.

  3. Use of Complementary and Alternative Medicine (CAM) in Autism Spectrum Disorder (ASD): Comparison of Chinese and Western Culture (Part A)

    Science.gov (United States)

    Wong, V. C. N.

    2009-01-01

    A cross-sectional survey of the use of CAM by children was undertaken in the Duchess of Kent Children's Hospital in Hong Kong (March-December 2006). A questionnaire survey concerning the use of CAM was administered to chief caretakers (only the mothers) who accompanied children with neurodevelopmental disabilities followed up in our…

  4. Use of Complementary and Alternative Medicine (CAM) in Autism Spectrum Disorder (ASD): Comparison of Chinese and Western Culture (Part A)

    Science.gov (United States)

    Wong, V. C. N.

    2009-01-01

    A cross-sectional survey of the use of CAM by children was undertaken in the Duchess of Kent Children's Hospital in Hong Kong (March-December 2006). A questionnaire survey concerning the use of CAM was administered to chief caretakers (only the mothers) who accompanied children with neurodevelopmental disabilities followed up in our…

  5. The structure of the cytochrome P450cam-putidaredoxin complex determined by paramagnetic NMR spectroscopy and crystallography

    NARCIS (Netherlands)

    Hiruma, Yoshitaka

    2014-01-01

    By utilizing paramagnetic NMR techniques, the structure and dynamics of the P450cam system were investigated. The analysis of PCS and RDC illuminated the stereo-specific final complex of Pdx and P450cam, while the results of PRE demonstrated the presence of a transient encounter complex.

  6. Ep-CAM expression in squamous cell carcinoma of the esophagus: a potential therapeutic target and prognostic marker

    Directory of Open Access Journals (Sweden)

    Peiper Matthias

    2006-06-01

    Full Text Available Abstract Background To evaluate the expression and test the clinical significance of the epithelial cellular adhesion molecule (Ep-CAM in esophageal squamous cell carcinoma (SCC to check the suitability of esophageal SCC patients for Ep-CAM directed targeted therapies. Methods The Ep-CAM expression was immunohistochemically investigated in 70 primary esophageal SCCs using the monoclonal antibody Ber-EP4. For the interpretation of the staining results, we used a standardized scoring system ranging from 0 to 3+. The survival analysis was calculated from 53 patients without distant metastasis, with R0 resection and at least 2 months of clinical follow-up. Results Ep-CAM neo-expression was observed in 79% of the tumors with three expression levels, 1+ (26%, 2+ (11% and 3+ (41%. Heterogeneous expression was observed at all expression levels. Interestingly, tumors with 3+ Ep-CAM expression conferred a significantly decreased median relapse-free survival period (log rank, p = 0.0001 and median overall survival (log rank, p = 0.0003. Multivariate survival analysis disclosed Ep-CAM 3+ expression as independent prognostic factor. Conclusion Our results suggest Ep-CAM as an attractive molecule for targeted therapy in esophageal SCC. Considering the discontenting results of the current adjuvant concepts for esophageal SCC patients, Ep-CAM might provide a promising target for an adjuvant immunotherapeutic intervention.

  7. Evaluating the prevalence, content and readability of complementary and alternative medicine (CAM) web pages on the internet.

    Science.gov (United States)

    Sagaram, Smitha; Walji, Muhammad; Bernstam, Elmer

    2002-01-01

    Complementary and alternative medicine (CAM) use is growing rapidly. As CAM is relatively unregulated, it is important to evaluate the type and availability of CAM information. The goal of this study is to deter-mine the prevalence, content and readability of online CAM information based on searches for arthritis, diabetes and fibromyalgia using four common search engines. Fifty-eight of 599 web pages retrieved by a "condition search" (9.6%) were CAM-oriented. Of 216 CAM pages found by the "condition" and "condition + herbs" searches, 78% were authored by commercial organizations, whose pur-pose involved commerce 69% of the time and 52.3% had no references. Although 98% of the CAM information was intended for consumers, the mean read-ability was at grade level 11. We conclude that consumers searching the web for health information are likely to encounter consumer-oriented CAM advertising, which is difficult to read and is not supported by the conventional literature.

  8. Electrooptical devices

    Science.gov (United States)

    Hurwitz, C. E.

    1980-03-01

    This report covers work carried out with support of the Department of the Air Force during the period 1 October 1979 through 31 March 1980. A part of this support was provided by the Rome Air Development Center. CW operation at temperatures up to 55 C has been achieved for GaInAsP/InP double-heterostructure (DH) lasers emitting at 1.5 micrometers, which were grown without a GaInAsP buffer layer. These devices are of interest for use as sources in fiber-optics communications systems, since the lowest transmission loss reported for fused-silica optical fibers occurs at 1.55 micrometers. Surface passivation techniques developed for InP and GaInAsP avalanche photodiodes have resulted in reductions of dark current as large as four orders of magnitude, to values as low as .0000016 A/sq cm at 0.9 V(b) where V(b) is the breakdown voltage. Devices consisting entirely of InP have been passivated with plasma-deposited Si3N4, and those with a GaInAsP layer but with the p-n junction in InP have been passivated with polyimide. Neither of these techniques successfully reduces dark currents in devices with the p-n junction in the GaInAsP, but a film of photoresist sprayed with SF6 as the propellant has given excellent results. The electrical characteristics in InP ion implanted with Sn, Ge, Si, and C have been investigated. All of these column IV elements yielded n-type conductivity and Sn, Ge, and Si showed high electrical activation; however, implanted C was found to have a net electrical activation of only about 5 percent.

  9. Eye tracking method on improved CamShift algorithm%改进CamShift算法的眼动跟踪方法

    Institute of Scientific and Technical Information of China (English)

    HUANG Yuan-gang; SANG Nan; HAO Zong-bo; JIANG Wei

    2014-01-01

    Since the CamShift algorithm only adopted color feature, which would result in the inaccuracy or failure of eye tracking in the situation of similar color objects,rapid movement of the head or deformation of the iris, this paper proposed an eye tracking m%针对CamShift跟踪算法仅采用颜色特征,在存在颜色相近干扰目标、头部快速运动或者虹膜发生形变等情况易发生眼动跟踪不准确或失败等问题,提出一种基于改进CamShift算法的眼动跟踪方法。在CamShift算法中,计算边缘直方图分布,在颜色特征基础上融合边缘特征,同时通过分析饱和度分量抑制噪声影响,并利用基于边缘特征的自定义方法判断虹膜是否发生形变。当发生形变时,自动更新模板,根据历史运动轨迹预测虹膜中心。实验表明,该方法能有效改善眼动跟踪性能,且定位虹膜精确、错误率低、速度快,预测虹膜中心与实际虹膜中心

  10. Criterios para Seleccionar Sistemas de Diseño y Manufactura Asistidos por Computadora (CAD/CAM Criteria for the Selection of Computer Aided Design and Manufacturing Systems (CAD/CAM

    Directory of Open Access Journals (Sweden)

    R.R. Martínez

    2004-01-01

    Full Text Available Este estudio tiene como objetivo presentar en forma clara los principios fundamentales que se requieren para tener un criterio sobre las bondades e inconvenientes de los sistemas Diseño y Manufactura Asistidos por Computadora (CAD/CAM. La inquietud nació por algunos problemas presentados en la primera adquisición de un sistema de CAD/CAM. Se adaptó a una máquina de Control Numérico por Computadora (CNC las dos modalidades de CAM, el primero con el sistema de CAD integrado y la otra con interacción en AutoCAD. Del análisis se determinó la indiferencia de usar un software de CAD desarrollado por la misma compañía del CAM. El resultado de estos experimentos y observaciones proporciona una herramienta fundamental para seleccionar un sistema de CAD/CAM eficienteThe objective of this study was to present in clear form the fundamental principles required to obtain a criterion of the advantages and disadvantages of computer aided design and manufacturing systems (CAD/CAM. The idea for setting these selection criteria were obtained during the initial acquisition of a CAD/CAM system. A Numerical Control by Computer (CNC machine was adapted to two modalities of CAM, the first with an integrated CAD system and another with AutoCAD interaction. From the analysis it was determined that it was immaterial whether or not the use of CAD software was from the same company that produced the CAM software. The results of these experiments and observations provide a fundamental tool for selecting an efficient CAD/CAM system

  11. Complementary and alternative medicine (CAM) use in an Italian cohort of pediatric headache patients: the tip of the iceberg.

    Science.gov (United States)

    Dalla Libera, D; Colombo, B; Pavan, G; Comi, G

    2014-05-01

    The use of complementary alternative medicine (CAM) in paediatric populations is considerably increased, especially for pain and chronic conditions, as demonstrated by epidemiological surveys both in Europe and in the USA. In our study, CAM was used in 76 % patients of a cohort of 124 children affected by headache (age 4-16 years; 67 % female; 70 % migraine without aura, 12 % migraine with aura, 18 % tensive headache according to IHS criteria) consecutively recruited at a Pediatric Headache University Center. CAM was used as preventive treatment in 80 % cases. The main reasons for seeking CAM were: the wish of avoiding chronic use of drugs with their related side effects, the desire of an integrated approach, the reported inefficacy of conventional medicine, and a more suitable children disposition to CAM than to pharmacological compound. Female gender, younger age, migraine without aura, parents' higher educational status, maternal use of CAM and other associated chronic conditions, correlated with CAM use (p insomnia, muscle-scheletric disorders and dysmenorrhoea). The most assumed CAM were: herbal remedies (64 %) such as Valeriana, Ginkgo biloba, Boswellia serrata, Vitex agnus-castus, passion flower, Linden tree; vitamins/minerals supplements (40 %) with magnesium, 5-Hydroxytryptophan, vitamin B6 or B12, Multivitamin compounds; Homeopathy (47 %) with Silicea, Ignatia Amara, Pulsatilla, Aconitum, Nux Vomica, Calcarea phosphorica; physical treatment (45 %) such as Ayurvedic massage, shiatsu, osteopathy; yoga (33 %); acupuncture (11 %). CAM-often integrated with conventional care-was auto-prescribed in 30 % of the cases, suggested by non-physician in 22 %, by the General Practitioner in 24 % and by paediatrician in 24 %. Both general practitioners and neurologists were mostly unaware of their patients' CAM use. In conclusion, neurologists should inquire for CAM use and be prepared to learn about CAM therapies or to directly interact with CAM trained experts, in

  12. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience.

    Science.gov (United States)

    Miyazaki, Takashi; Hotta, Yasuhiro; Kunii, Jun; Kuriyama, Soichi; Tamaki, Yukimichi

    2009-01-01

    In this article, we review the recent history of the development of dental CAD/CAM systems for the fabrication of crowns and fixed partial dentures (FPDs), based on our 20 years of experience in this field. The current status of commercial dental CAD/CAM systems developed around the world is evaluated, with particular focus on the field of ceramic crowns and FPDs. Finally, we discuss the future perspectives applicable to dental CAD/CAM. The use of dental CAD/CAM systems is promising not only in the field of crowns and FPDs but also in other fields of dentistry, even if the contribution is presently limited. CAD/CAM technology will contribute to patients' health and QOL in the aging society.

  13. Predictable aesthetic replacement of a metal-ceramic crown using CAD/CAM technology: a case report.

    Science.gov (United States)

    Poticny, Daniel; Conrad, Robert

    2005-08-01

    The currently available CAD/CAM technologies present clinicians with various clinical benefits that include durability, marginal adaptation, and precision aesthetics. The clinical and laboratory procedures associated with these CAD/CAM systems differ from one another, and practitioners must understand the indications for each. Office-based systems, as demonstrated in the following case presentation, allow excellent results to be achieved in a single patient visit and provide a viable alternative for today's practice. This case report describes the associated sequences for a posterior CAD/CAM restoration. Learning Objectives This article discusses a protocol for the use of CAD/CAM restorations in the aesthetic replacement of defective posterior crowns. Upon reading this article, the reader should have: * Greater understanding of the in-office CAD/CAM procedures used to fabricate single-visit crowns. * Improved awareness of the bonding protocol used for these all-ceramic crowns.

  14. On the improvement design of dynamic characteristics for the roller follower of a variable-speed plate cam mechanism

    Science.gov (United States)

    Fan, Hui Ching; Yan, Hong Sen

    2012-03-01

    Without modifying the cam contour, a cam mechanism with a variable input speed trajectory offers an alternative solution to flexibly achieve kinematic and dynamic characteristics, and then decrease the follower's residual vibration. Firstly, the speed trajectory of cam is derived by employing Bezier curve, and motion continuity conditions are investigated. Then the motion characteristics between the plate cam and its roller follower are derived. To analyze the residual vibration, a single degree of freedom dynamic model of the elastic cam-follower system is introduced. Based on the motion equation derived from the dynamic model, the residual vibration of the follower is yielded. The design procedure to improve the kinematic and dynamic motion characteristics is presented and two design examples with discussions are provided. Finally, the simulations of the kinematic and dynamic models by ADAMS are carried out and verified that the design models as well as the performances of the mechanism are feasible.

  15. Structural Design and Simulation of Passive Low Gravity Compensation for the Deployable Arm in the Device of Drilling and Collecting Lunar Soil

    Directory of Open Access Journals (Sweden)

    Tao Jianguo

    2015-01-01

    Full Text Available As an important constituent part of the sampling device for lunar soil drilling, the deployable arm can help transfer the samples and avoid stretching. According to the ground experimental research requirements for deployable arm, this paper proposed a low-gravity compensation method of passive cam counter weight by establishing a Lagrangian dynamics model of deployable arm. It is emphasized on designing the profile curve of cam mechanism and the mechanical structure of cam component. By using ADAMS software, this paper conducted kinematics analogue simulation and obtained the kinematic parameters of deployable arm under the environmental conditions of the lunar surface and of the ground surface. The comparison of the analogue results has verified the necessity and reasonability of this compensation method. At last, this paper reached the conclusions and proposed measures to improve the compensation device. This paper can offer certain technical reference for the ground experiment of the sampling mechanism used for lunar drilling and the engineering implementation.

  16. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  17. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  18. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  19. Stratification devices

    DEFF Research Database (Denmark)

    Andersen, Elsa; Furbo, Simon

    2008-01-01

    heating system. High temperatures in the top of the storage tank established by the energy from the solar collector reduce the use of auxiliary energy. Low temperatures in the bottom of the storage tank improve the operation conditions for the solar collector. Using thermal stratified heat storages...... results in longer operation periods and improved utilization of the solar collector. Thermal stratification can be achieved, for example by using inlet stratification devices at all inlets to the storage tank. This paper presents how thermal stratification is established and utilized by means of inlet......Thermal stratification in the storage tank is extremely important in order to achieve high thermal performance of a solar heating system. High temperatures in the top of the storage tank and low temperatures in the bottom of the storage tank lead to the best operation conditions for any solar...

  20. Thermography of semi-transparent materials by a FLIR ThermaCAM SC3000 infrared camera

    NARCIS (Netherlands)

    Van der Tempel, L.

    2011-01-01

    An acceptance test for thermography of semi-transparent materials by a FLIR ThermaCAM SC3000 infrared camera with 8.0 µm low-wavelength-pass filter has been developed and performed on polycarbonate, PEN, quartz, Corning 1737 glass, G427 cone glas, G443 screen glass, Schott Zerodur, silicon and a

  1. ESA ExoMars: Pre-launch PanCam Geometric Modeling and Accuracy Assessment

    Science.gov (United States)

    Li, D.; Li, R.; Yilmaz, A.

    2014-08-01

    ExoMars is the flagship mission of the European Space Agency (ESA) Aurora Programme. The mobile scientific platform, or rover, will carry a drill and a suite of instruments dedicated to exobiology and geochemistry research. As the ExoMars rover is designed to travel kilometres over the Martian surface, high-precision rover localization and topographic mapping will be critical for traverse path planning and safe planetary surface operations. For such purposes, the ExoMars rover Panoramic Camera system (PanCam) will acquire images that are processed into an imagery network providing vision information for photogrammetric algorithms to localize the rover and generate 3-D mapping products. Since the design of the ExoMars PanCam will influence localization and mapping accuracy, quantitative error analysis of the PanCam design will improve scientists' awareness of the achievable level of accuracy, and enable the PanCam design team to optimize its design to achieve the highest possible level of localization and mapping accuracy. Based on photogrammetric principles and uncertainty propagation theory, we have developed a method to theoretically analyze how mapping and localization accuracy would be affected by various factors, such as length of stereo hard-baseline, focal length, and pixel size, etc.

  2. Education & Training for CAD/CAM: Results of a National Probability Survey. Krannert Institute Paper Series.

    Science.gov (United States)

    Majchrzak, Ann

    A study was conducted of the training programs used by plants with Computer Automated Design/Computer Automated Manufacturing (CAD/CAM) to help their employees adapt to automated manufacturing. The study sought to determine the relative priorities of manufacturing establishments for training certain workers in certain skills; the status of…

  3. Classroom Experiences in an Engineering Design Graphics Course with a CAD/CAM Extension.

    Science.gov (United States)

    Barr, Ronald E.; Juricic, Davor

    1997-01-01

    Reports on the development of a new CAD/CAM laboratory experience for an Engineering Design Graphics (EDG) course. The EDG curriculum included freehand sketching, introduction to Computer-Aided Design and Drafting (CADD), and emphasized 3-D solid modeling. Reviews the project and reports on the testing of the new laboratory components which were…

  4. Thermography of semi-transparent materials by a FLIR ThermaCAM SC3000 infrared camera

    NARCIS (Netherlands)

    Van der Tempel, L.

    2011-01-01

    An acceptance test for thermography of semi-transparent materials by a FLIR ThermaCAM SC3000 infrared camera with 8.0 µm low-wavelength-pass filter has been developed and performed on polycarbonate, PEN, quartz, Corning 1737 glass, G427 cone glas, G443 screen glass, Schott Zerodur, silicon and a bl

  5. EGFR-Based Immunoisolation as a Recovery Target for Low-EpCAM CTC Subpopulation

    Science.gov (United States)

    Vila, Ana; Abal, Miguel; Muinelo-Romay, Laura; Rodriguez-Abreu, Carlos; Rivas, José; López-López, Rafael; Costa, Clotilde

    2016-01-01

    Circulating tumour cells (CTCs) play a key role in the metastasis process, as they are responsible for micrometastasis and are a valuable tool for monitoring patients in real-time. Moreover, efforts to develop new strategies for CTCs isolation and characterisation, and the translation of CTCs into clinical practice needs to overcome the limitation associated with the sole use of Epithelial Cell Adhesion Molecule (EpCAM) expression to purify this tumour cell subpopulation. CTCs are rare events in the blood of patients and are believed to represent the epithelial population from a primary tumour of epithelial origin, thus EpCAM immunoisolation is considered an appropriate strategy. The controversy stems from the impact that the more aggressive mesenchymal tumour phenotypes might have on the whole CTC population. In this work, we first characterised a panel of cell lines representative of tumour heterogeneity, confirming the existence of tumour cell subpopulations with restricted epithelial features and supporting the limitations of EpCAM-based technologies. We next developed customised polystyrene magnetic beads coated with antibodies to efficiently isolate the phenotypically different subpopulations of CTCs from the peripheral blood mononuclear cells (PBMCs) of patients with metastatic cancer. Besides EpCAM, we propose Epidermal Growth Factor Receptor (EGFR) as an additional isolation marker for efficient CTCs detection. PMID:27711186

  6. Effects of Complementary and Alternative Medicines (CAM) on the Metabolism and Transport of Anticancer Drugs

    NARCIS (Netherlands)

    Mooiman, K.D.|info:eu-repo/dai/nl/357798902

    2013-01-01

    The use of complementary and alternative medicines (CAM), such as herbs and dietary supplements, has become more popular among cancer patients. Cancer patients use these supplements for different reasons such as reduction of side effects and improvement of their quality of life. In general, the use

  7. Development of Integrated ASR Model Forcing Data and Their Applications to Improve CAM

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Minghua [Research Foundation of the State University of New York, Albany, NY (United States)

    2016-01-01

    In this project, we have (1) improved the constrained variational analysis algorithm of ARM model forcing data, and (2) used the ARM forcing data to identify systematic biases in clouds and radiation in the CAM5 and design new physical parameterizations to improve it.

  8. Winning in the Rural Zone: How Cam Henderson Invented the Zone Defense.

    Science.gov (United States)

    Barnett, Bob

    1992-01-01

    Assesses the distinguished coaching career of Cam Henderson, who won over 611 games in 36 seasons of college basketball and coached over 151 college football wins at West Virginia colleges, mainly at Marshall University (Huntington). His influence has been so pervasive that Marshall University's basketball arena is named in his honor. (LP)

  9. OmegaCAM: the 16k × 16k Survey Camera for the VLT Survey Telescope

    NARCIS (Netherlands)

    Deul, Erik; Kuijken, Konrad; Valentijn, Edwin A.; Tyson, J. Anthony; Wolff, Sidney

    2002-01-01

    OmegaCAM, a 16k×16k-pixel wide field optical camera, and the VLT Survey Telescope (VST) that is to host it, will constitute a major sky surveying machine that becomes operational in 2004 at ESO"s Paranal Observatory. It maps one square degree of sky with 0.21 arcsec sized pixels. Both individual pro

  10. Leadless Chip Carrier Packaging and CAD/CAM-Supported Wire Wrap Interconnect Technology for Subnanosecond ECL.

    Science.gov (United States)

    1981-11-01

    Aided Manufacturing Software J. M. Dubin : CAD/CAM Demonstration Circuit Design, Fabrica- tion, and Test L. M. Krueger: ECL Design Protocols R. D...the electro - plating fingers is further compounded by the presence of yet another set of plating fingers, which may be detected in Figure 24 between the

  11. The RCCM 2009 Survey: Mapping Doctoral and Postdoctoral CAM Research in the United Kingdom

    Directory of Open Access Journals (Sweden)

    Nicola Robinson

    2011-01-01

    Full Text Available Complementary and Alternative Medicine (CAM is widely available in the UK and used frequently by the public, but there is little high quality research to sustain its continued use and potential integration into the NHS. There is, therefore, a need to develop rigorous research in this area. One essential way forward is to train and develop more CAM researchers so that we can enhance academic capacity and provide the evidence upon which to base strategic healthcare decisions. This UK survey identified 80 research active postgraduates registered for MPhils/PhDs in 21 universities and were either current students or had completed their postgraduate degree during the recent UK Research Assessment Exercise (RAE 2001–2008. The single largest postgraduate degree funder was the university where the students registered (26/80. Thirty-two projects involved randomized controlled trials and 33 used qualitative research methods. The UK RAE also indicates a significant growth of postdoctoral and tenured research activity over this period (in 2001 there were three full time equivalents; in 2008 there were 15.5 with a considerable improvement in research quality. This mapping exercise suggests that considerable effort is currently being invested in developing UK CAM research capacity and thus inform decision making in this area. However, in comparative international terms UK funding is very limited. As in the USA and Australia, a centralized and strategic approach by the National Institute of Health Research to this currently uncoordinated and underfunded activity may benefit CAM research in the UK.

  12. Perapation of mica-based glassceramics for denta CAD/CAM system

    Institute of Scientific and Technical Information of China (English)

    LI Hong; RAN Junguo; GOU Li; ZHAO Yunfeng

    2001-01-01

    @@ Ceramic materials have received considerable application in biomedical and dental restoration because of their relative higher mechanical properties, excellent biocompatibility and good natural aesthetics. Development of machinable glass-ceramicsin dental CAD/CAM maching system have provided a new impetus for fabrication ofceramic restorations.

  13. Rocknest, Bradbury Plateau, and Kimberly: Iron Cemented Sediments Observed in Gale Crater with ChemCam

    Science.gov (United States)

    Blaney, D. L.; Wiens, R. C.; Maurice, S.; Clegg, S. M.; Anderson, R. B.; Kahn, L. C.; Le Mouélic, S.; Ollila, A.; Gerger, G.; Bridges, J. C.; Cousin, A.; Clark, B.; Dyar, M. D.; King, P. L.; Mangold, N.; Meslin, P. Y.; Newsom, H.; Schröder, S.; Rowland, S.; Johnson, J.; Edgar, L.; Forni, O.; Schmidt, M.; Goetz, W.; Stack, K.; Sumner, D.; Fisk, M.; Maden, M. B.; Tokar, R.; MSL Science Team

    2014-07-01

    Numerous locations with Fe-rich cements were identified at Gale Crater with ChemCam. This indicates that Fe-rich waters were widespread in the area explored. Rocks also experienced different diagenetic histories involving Mg loss, sulfates, and CaF.

  14. Soil diversity and hydration as observed by ChemCam at Gale Crater, Mars

    NARCIS (Netherlands)

    Meslin, P.-Y.; Gasnault, O.; Forni, O.; Schröder, S.; Cousin, A.; Berger, G.; Clegg, S.M.; Lasue, J.; Maurice, S.; Sautter, V.; Le Mouélic, S.; Wiens, R.C.; Fabre, C.; Goetz, W.; Bish, D.; Mangold, N.; Ehlmann, B.; Lanza, N.; Harri, A.-M.; Anderson, R.; Rampe, E.; McConnochie, T.H.; Pinet, P.; Blaney, D.; Léveillé, R.; Archer, D.; Barraclough, B.; Bender, S.; Blake, D.; Blank, J.G.; Bridges, N.; Clark, B.C.; DeFlores, L.; Delapp, D.; Dromart, G.; Dyar, M.D.; Fisk, M.; Gondet, B.; Grotzinger, J.; Herkenhoff, K.; Johnson, J.; Lacour, J.-L.; Langevin, Y.; Leshin, L.; Lewin, E.; Madsen, M.B.; Melikechi, N.; Mezzacappa, A.; Mischna, M.A.; Moores, J.E.; Newsom, H.; Ollila, A.; Perez, R.; Renno, N.; Sirven, J.-B.; Tokar, R.; De La Torre, M.; D'Uston, L.; Vaniman, D.; Yingst, A.; MSL Science Team, the

    2013-01-01

    The ChemCam instrument, which provides insight into martian soil chemistry at the submillimeter scale, identified two principal soil types along the Curiosity rover traverse: a fine-grained mafic type and a locally derived, coarse-grained felsic type. The mafic soil component is representative of wi

  15. MASA syndrome is caused by mutations in the neural cell adhesion gene, L1CAM

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, C.E.; Wang, Y.; Schroer, R.J.; Stevenson, R.E. [Greenwood Genetic Center, SC (United States)

    1994-09-01

    The MASA syndrome is a recessive X-linked disorder characterized by Mental retardation, Adducted thumbs, Shuffling gait and Aphasia. Recently we found that MASA in one family was likely caused by a point mutation in exon 6 of the L1CAM gene. This gene has also been shown to be involved in X-linked hydrocephalus (HSAS). We have screened 60 patients with either sporadic HSAS or MASA as well as two additional families with MASA. For the screening, we initially utilized 3 cDNA probes for the L1CAM gene. In one of the MASA families, K8310, two affected males were found to have an altered BglII band. The band was present in their carrier mother but not in their normal brothers. This band was detected by the entire cDNA probe as well as the cDNA probe for 3{prime} end of the gene. Analysis of the L1CAM sequence indicated the altered BglII site is distal to the exon 28 but proximal to the punative poly A signal site. It is hypothesized that this point mutation alters the stability of the L1CAM mRNA. This is being tested using cell lines established from the two affected males.

  16. Input torque balancing using a cam-based centrifugal pendulum: design procedure and example

    Science.gov (United States)

    Demeulenaere, Bram; Spaepen, Pieter; De Schutter, Joris

    2005-05-01

    Input torque balancing is a well-known way to reduce drive speed fluctuations in high-speed machinery and combustion engines. This paper introduces a cam-based centrifugal pendulum (CBCP) and a design procedure for it which results in quasi-perfect balancing of inertial torques for any drive speed. The CBCP combines the centrifugal pendulum vibration absorber, well-known in mechanical vibration literature, with a torque balancing principle well-known in mechanism literature, that is, the use of cams to generate arbitrary torques. For given design parameters (such as the link lengths and link inertial parameters), the cam design is governed by a nonlinear, second-order, explicit differential equation. This differential equation is numerically solved by reformulating it as a nonlinear least-squares problem. The design parameters themselves are determined by means of an optimization problem, the goal of which is to minimize the (constant) equivalent inertia of the combined system, consisting of the original mechanism to be balanced and the CBCP. Application of the CBCP to torque balance a high-speed, purely inertial cam-follower mechanism, driving the sley of a weaving loom, shows that the optimization results in a compact and technologically feasible mechanism.

  17. The Cyborg Astrobiologist: porting from a wearable computer to the Astrobiology Phone-cam

    Science.gov (United States)

    Bartolo, Alexandra; McGuire, Patrick C.; Camilleri, Kenneth P.; Spiteri, Christopher; Borg, Jonathan C.; Farrugia, Philip J.; Ormö, Jens; Gómez-Elvira, Javier; Rodriguez-Manfredi, José Antonio; Díaz-Martínez, Enrique; Ritter, Helge; Haschke, Robert; Oesker, Markus; Ontrup, Jörg

    2007-08-01

    We have used a simple camera phone to significantly improve an `exploration system' for astrobiology and geology. This camera phone will make it much easier to develop and test computer-vision algorithms for future planetary exploration. We envision that the `Astrobiology Phone-cam' exploration system can be fruitfully used in other problem domains as well.

  18. An EGP-2/Ep-CAM-expressing transgenic rat model to evaluate antibody-mediated immunotherapy

    NARCIS (Netherlands)

    McLaughlin, PMJ; Kroesen, BJ; Dokter, WHA; van der Molen, H; de Groot, M; Brinker, MGL; Kok, K; Ruiters, MHJ; Buys, CHCM; de Leij, LFMH

    1999-01-01

    The human pancarcinoma-associated epithelial glycoprotein-2 (EGP-2), also known as 17-1A or EpCAM, is a 38-kDa transmembrane antigen, commonly used for targeted immunotherapy of carcinomas. Although strongly expressed by most carcinomas, EGP-2 is also expressed in most simple epithelia. To evaluate

  19. Comparison of CAD-CAM and hand made sockets for PTB prostheses.

    Science.gov (United States)

    Köhler, P; Lindh, L; Netz, P

    1989-04-01

    The aim of the present study was to compare sockets for below-knee (BK) prostheses made by Computer Aided Design-Computer Aided Manufacture (CAD-CAM) to those made by hand. The patients in the study were provided with two prostheses each, which apart from the sockets, were identical. One socket was made by the CAD-CAM technique developed at the Bioengineering Centre, Roehampton, University College London and one was made by hand at the OT-Centre, Stockholm, Sweden. The results were based on investigation of eight unilateral below-knee amputees evaluating their own sockets by Visual Analogous Scale with respect to comfort, pressure, and pain. The sockets were evaluated on seven occasions, at two tests, on delivery, after use every second day for six days and every second week for two weeks. All CAD-CAM sockets except one had to be changed once as compared to the hand made of which only two had to be changed. As to comfort it could not be demonstrated that there was any significant difference between the two types of sockets and both types were well accepted by all patients. Differences in pressure and pain were rarely reported. There were obvious differences between the two types of socket with respect to height, width, and inner surface configuration. The authors feel that CAD-CAM will in the near future be an excellent tool for design and manufacture of prosthetic sockets.

  20. A distributed data base management facility for the CAD/CAM environment

    Science.gov (United States)

    Balza, R. M.; Beaudet, R. W.; Johnson, H. R.

    1984-01-01

    Current/PAD research in the area of distributed data base management considers facilities for supporting CAD/CAM data management in a heterogeneous network of computers encompassing multiple data base managers supporting a variety of data models. These facilities include coordinated execution of multiple DBMSs to provide for administration of and access to data distributed across them.

  1. CLIC main beam quadrupole active pre-alignment based on cam movers

    CERN Document Server

    Kemppinen, J; Leuxe, R; Mainaud Durand, H; Sandomierski, J; Sosin, M

    2012-01-01

    Compact Linear Collider (CLIC) is a study for a future 48 km long linear electron-positron collider in the multi TeV range. Its target luminosity can only be reached if the main beam quadrupoles (MB quads) are actively pre-aligned within 17 µm in sliding windows of 200 m with respect to a straight reference line. In addition to the positioning requirement, the pre-alignment system has to provide a rigid support for the nano-stabilization system to ensure that the first eigenfrequency is above 100 Hz. Re-adjustment based on cam movers was chosen for detailed studies to meet the stringent pre-alignment requirements. There are four different types of MB quads in CLIC. Their lengths and masses vary so that at least two types of cam movers have to be developed. The validation of the cams with less stringent space restrictions has proceeded to a test setup in 5 degrees of freedom (DOF). Prototypes of the more demanding, smaller cams have been manufactured and they are under tests in 1 DOF. This paper describes the...

  2. EpCAM Expression in Lymph Node and Bone Metastases of Prostate Carcinoma : A Pilot Study

    NARCIS (Netherlands)

    Campos, Anna K.; Hoving, Hilde D.; Rosati, Stefano; van Leenders, Geert J. L. H.; de Jong, Igle J.

    2016-01-01

    There is an urgent need for new imaging modalities in prostate carcinoma staging. A non-invasive modality that can assess lymph node and bone metastases simultaneously is preferred. Epithelial cell adhesion molecule (EpCAM) is a membranous protein of interest as an imaging target since it is overexp

  3. EpCAM expression in lymph node and bone metastases of prostate carcinoma: A pilot study

    NARCIS (Netherlands)

    Campos, A.K. (Anna K.); Hoving, H.D. (Hilde D.); S. Rosati (Stefano); G.J.H.L. Leenders (Geert); I.J. de Jong (Igle)

    2016-01-01

    textabstractThere is an urgent need for new imaging modalities in prostate carcinoma staging. A non-invasive modality that can assess lymph node and bone metastases simultaneously is preferred. Epithelial cell adhesion molecule (EpCAM) is a membranous protein of interest as an imaging target since i

  4. GravityCam: wide-field, high-resolution imaging and high-speed photometry instrument

    Science.gov (United States)

    MacKay, Craig; Dominik, Martin; Steele, Iain

    2016-08-01

    The limits to the angular resolution achievable with conventional ground-based telescopes are unchanged over 70 years. Atmospheric turbulence limits image quality to typically 1 arcsec in practice. We have developed a new concept of ground-based imaging instrument called GravityCam capable of delivering significantly sharper images from the ground than is normally possible without adaptive optics. The acquisition of visible images at high speed without significant noise penalty has been made possible by advances in optical and near IR imaging technologies. Images are recorded at high speed and then aligned before combination and can yield a 3-5 fold improvement in image resolution. Very wide survey fields are possible with widefield telescope optics. We describe GravityCam and detail its application to accelerate greatly the rate of detection of Earth size planets by gravitational microlensing. GravityCam will also improve substantially the quality of weak shear studies of dark matter distribution in distant clusters of galaxies. The microlensing survey will also provide a vast dataset for asteroseismology studies. In addition, GravityCam promises to generate a unique data set that will help us understand of the population of the Kuiper belt and possibly the Oort cloud.

  5. Hydrocephalus and intestinal aganglionosis : Is L1CAM a modifier gene in Hirschsprung disease?

    NARCIS (Netherlands)

    Parisi, MA; Kapur, RP; Neilson, [No Value; Hofstra, RMW; Holloway, LW; Michaelis, RC; Leppig, KA

    2002-01-01

    Congenital hydrocephalus associated with aqueductal stenosis and/or agenesis of the corpus callosum has been described in newborn males with mutations in L1CAM, a gene that encodes a neural cell adhesion molecule. These males usually have severe mental retardation and may have spastic paraplegia and

  6. Monitoring the photometric behavior of OmegaCAM with Astro-WISE

    CERN Document Server

    Kleijn, Gijs A Verdoes; Valentijn, Edwin A; Boxhoorn, Danny R; Begeman, Kor G; Deul, Erik R; Helmich, Ewout M; Rengelink, Roeland

    2012-01-01

    The OmegaCAM wide-field optical imager is the sole instrument on the VLT Survey Telescope at ESO's Paranal Observatory. The instrument, as well as the telescope, have been designed for surveys with very good, natural seeing-limited image quality over a 1 square degree field. OmegaCAM was commissioned in 2011 and has been observing three ESO Public Surveys in parallel since October 15, 2011. We use the Astro-WISE information system to monitor the calibration of the observatory and to produce the Kilo Degree Survey (KiDS). Here we describe the photometric monitoring procedures in Astro-WISE and give a first impression of OmegaCAM's photometric behavior as a function of time. The long-term monitoring of the observatory goes hand in hand with the KiDS survey production in Astro-WISE. KiDS is observed under partially non-photometric conditions. Based on the first year of OmegaCAM operations it is expected that a $\\sim 1%-2%$ photometric homogeneity will be achieved for KiDS.

  7. A distributed data base management facility for the CAD/CAM environment

    Science.gov (United States)

    Balza, R. M.; Beaudet, R. W.; Johnson, H. R.

    1984-01-01

    Current/PAD research in the area of distributed data base management considers facilities for supporting CAD/CAM data management in a heterogeneous network of computers encompassing multiple data base managers supporting a variety of data models. These facilities include coordinated execution of multiple DBMSs to provide for administration of and access to data distributed across them.

  8. Cam deformity and acetabular dysplasia as risk factors for hip osteoarthritis.

    NARCIS (Netherlands)

    Hosnijeh, Fatemeh Saberi; Zuiderwijk, Maria E; Versteeg, Mathijs; Smeele, Hieronymus T W; Hofman, Albert; Uitterlinden, André G; Agricola, Rintje; Oei, Edwin H G; Waarsing, Jan H; Bierma-Zeinstra, Sita M; van Meurs, Joyce B J

    2017-01-01

    Objective: Cam deformity and acetabular dysplasia have been recognized as relevant risk factors for hip osteoarthritis (OA) in a few prospective studies with limited sample sizes. To date, however, no evidence is available from prospective studies regarding whether the magnitude of these

  9. The C.A.M.S. 54 G.R. transatlantic seaplane (French)

    Science.gov (United States)

    Ide, John Jay

    1928-01-01

    Tested at the end of March, 1928, the C.A.M.S. 54 G.R. was built for the purpose of crossing the Atlantic from Europe by way of the azores. It has a biplane construction with wings mounted above the hull. It is powered by two new series 500 HP. geared Hispano Suiza V type engines.

  10. Effects of Complementary and Alternative Medicines (CAM) on the Metabolism and Transport of Anticancer Drugs

    NARCIS (Netherlands)

    Mooiman, K.D.

    2013-01-01

    The use of complementary and alternative medicines (CAM), such as herbs and dietary supplements, has become more popular among cancer patients. Cancer patients use these supplements for different reasons such as reduction of side effects and improvement of their quality of life. In general, the use

  11. Preparation Junctions for All-Ceramic CAD/CAM Crown and Bridge Restorations

    Directory of Open Access Journals (Sweden)

    Vlahova Angelina

    2016-07-01

    Full Text Available Background: The preparation junction type is determined by a number of factors that need to be taken in consideration with CAD/CAM Fixed Prosthodontics: the used material; the condition of the retainer teeth, their periodontium and the occlusion; the design software and the type of drills; the working protocol; the cement and the method of cementation.

  12. Force Analysis of Geneva Wheel and Face Cam Used In Automat

    Directory of Open Access Journals (Sweden)

    Madhoo G

    2014-06-01

    Full Text Available Glazerol Automat is a dedicated machine used in the Insulator pre assembly line. This automat is driven using single motor for different operations. Here the focus is on two main parts they are Geneva wheel and Face cam which are used for their respective operations. Geneva Wheel is used to index the drum which consists of 96 spindles. Due to this Geneva mechanism each of the spindles will hold the ceramic body when the drum is being indexed. Due to which there is a force which is generated in the Geneva wheel in maximum and minimum position. Face cam which is used while indexing the work piece carrier There are 2 tangential forces which are acting, one at the indexing side and the other at the driving side /cam side. The effective resultant force which is acting on the face cam while indexing work piece carrier is calculated. And these forces are analyzed using ansys and their respective Von Mises stresses and displacement plots are obtained for both the conditions based on boundary and loading conditions.

  13. The prevalence, patterns of usage and people's attitude towards complementary and alternative medicine (CAM among the Indian community in Chatsworth, South Africa

    Directory of Open Access Journals (Sweden)

    Raidoo Deshandra M

    2004-02-01

    Full Text Available Abstract Background The purpose of this study was to determine, among the Indian community of Chatsworth, South Africa, the prevalence and utilisation patterns of complementary and alternative medicine (CAM, attitudes associated with CAM use and communication patterns of CAM users with their primary care doctors. Methods Face-to-face structured interviews were conducted in Chatsworth, a suburb of Durban in which South Africans of Indian origin predominantly reside. Participants were 200 randomly selected adult English-speaking Indian residents. Results The prevalence of CAM usage for period 2000/2001 was 38.5% (95% confidence interval 31.7% to 45.6%. Spiritual healing and herbal/natural medicines, including vitamins were the most common types of CAM used, accounting for 42.8% and 48.1% respectively of overall CAM usage. People used CAM to treat conditions including diabetes mellitus, headaches, arthritis and joint pains, stress, skin disorders, backaches, hypertension and nasal disorders. Half of the CAM users used allopathic medicines concurrently. The cost of CAM utilization over this 1-year period, incurred by 80.5% of users for the duration of therapy for their most troublesome condition was below R500 (approximately US$50. Age, sex, marital status, religion, level of education and income were shown not to influence the use of CAM. Greater than half (51.9% of CAM users did so either upon the advice of someone they knew, or after noticing a CAM advertisement in the local press. Seventy-nine percent of CAM users indicated that they had positive outcomes with their treatments. Fifty four percent of CAM users (excluding those using spiritual healing only failed to inform their doctors that they used CAM. The main reason given by half of this group was that informing their doctors did not seem necessary. Conclusion The prevalence of CAM in Chatsworth is similar to findings in other parts of the world. Although CAM was used to treat many different

  14. Child/Adolescent Anxiety Multimodal Study (CAMS: rationale, design, and methods

    Directory of Open Access Journals (Sweden)

    Waslick Bruce D

    2010-01-01

    Full Text Available Abstract Objective To present the design, methods, and rationale of the Child/Adolescent Anxiety Multimodal Study (CAMS, a recently completed federally-funded, multi-site, randomized placebo-controlled trial that examined the relative efficacy of cognitive-behavior therapy (CBT, sertraline (SRT, and their combination (COMB against pill placebo (PBO for the treatment of separation anxiety disorder (SAD, generalized anxiety disorder (GAD and social phobia (SoP in children and adolescents. Methods Following a brief review of the acute outcomes of the CAMS trial, as well as the psychosocial and pharmacologic treatment literature for pediatric anxiety disorders, the design and methods of the CAMS trial are described. Results CAMS was a six-year, six-site, randomized controlled trial. Four hundred eighty-eight (N = 488 children and adolescents (ages 7-17 years with DSM-IV-TR diagnoses of SAD, GAD, or SoP were randomly assigned to one of four treatment conditions: CBT, SRT, COMB, or PBO. Assessments of anxiety symptoms, safety, and functional outcomes, as well as putative mediators and moderators of treatment response were completed in a multi-measure, multi-informant fashion. Manual-based therapies, trained clinicians and independent evaluators were used to ensure treatment and assessment fidelity. A multi-layered administrative structure with representation from all sites facilitated cross-site coordination of the entire trial, study protocols and quality assurance. Conclusions CAMS offers a model for clinical trials methods applicable to psychosocial and psychopharmacological comparative treatment trials by using state-of-the-art methods and rigorous cross-site quality controls. CAMS also provided a large-scale examination of the relative and combined efficacy and safety of the best evidenced-based psychosocial (CBT and pharmacologic (SSRI treatments to date for the most commonly occurring pediatric anxiety disorders. Primary and secondary results

  15. Does complementary and alternative medicine (CAM) use reduce negative life impact of headaches for chronic migraineurs? A national survey.

    Science.gov (United States)

    Lee, Jieun; Bhowmick, Amrita; Wachholtz, Amy

    2016-01-01

    Chronic migraine is a disabling condition that impacts multiple aspects of migraineurs' lives. Although pharmacological treatments can help to treat the pain associated with migraine headache, chronic migraineurs often experience side-effects of pharmacological treatments. Those experiences may contribute to the observed growth in complementary and alternative medicine (CAM) use among migraineurs. Relatively little is known about the patterns of CAM treatment and the characteristics of chronic migraineurs. Therefore, the purpose of the present study is to investigate the characteristics of chronic migraineurs who use CAM treatment and the relationship among satisfaction with current CAM use, negative life impact, migraine outcomes, and psychiatric comorbidities among chronic migraineurs. 2907 participants were recruited from a well-known online migraine headache resource. All participants were US adults aged 18 years or older. Migraineurs are referred to this website through various routes (e.g., referral from healthcare providers, internet search, obtaining information from research papers, personal invitation from other users, and information shared on social media etc.). Participants completed a 30-min self-report-survey in the spring of 2014. Almost half of the participants reported that they are currently using more than three different CAM treatments even though the majority of the participants reported neutral or dissatisfied with their current CAM treatment. Chronic migraineurs who use CAM treatments were more likely to experience prolonged or frequent migraine headaches (p = .018, η(2) = .0021), and experience greater negative life impact from their headaches (p = .000, η(2) = .0172) compared to non-CAM users. CAM treatment satisfaction was inversely related to the number of psychiatric comorbidities, frequency of migraines, and number of migraine symptoms (p's < .05). However, CAM treatment satisfaction was more strongly correlated with

  16. 基于二部制的价格歧视方法%Price Discrimination Method Based on Two-parts Tariff

    Institute of Scientific and Technical Information of China (English)

    彭云飞

    2012-01-01

    产品实施价格二部制的企业大量采用二级价格歧视、三级价格歧视方法外,还存在混合价格歧视.研究表明:企业收益最大化目标下实施这些价格歧视方法时,固定价格和从量价格的需求弹性、用户数、单位时间里的收益以及用户区间、资费区间分别需要满足不同的条件.这些结论为企业实施二部价格歧视提供了理论依据和决策参考.%Second-degree and third-degree price discriminaions are widely adopted in he product pricing. Research shows: under the constraints of income maximization, some con-ditions for the fixed fee of service packages and the demand elasticity of the quantity rate of bundled services, the number of users, the income per unit time, the users; and price's intervals should be meet in order to implement these price discrimination decision-making methods. These conclusions provide the theoretical and decision-making bases when the enterprises carry out two parts price discrimination

  17. Diagnosing delirium in elderly Thai patients: Utilization of the CAM algorithm

    Directory of Open Access Journals (Sweden)

    Lerttrakarnnon Peerasak

    2011-07-01

    Full Text Available Abstract Background Delirium is a common illness among elderly hospitalized patients. However, under-recognition of the condition by non-psychiatrically trained personnel is prevalent. This study investigated the performance of family physicians when detecting delirum in elderly hospitalized Thai patients using the Thai version of the Confusion Assessment Method (CAM algorithm. Methods A Thai version of the CAM algorithm was developed, and three experienced Thai family physicians were trained in its use. The diagnosis of delirium was also carried out by four fully qualified psychiatrists using DSM-IV TR criteria, which can be considered the gold standard. Sixty-six elderly patients were assessed with MMSE Thai 2002, in order to evaluate whether they had dementia upon admission. Within three days of admission, each patient was interviewed separately by a psychiatrist using DSM-IV TR, and a family physician using the Thai version of the CAM algorithm, with both sets of interviewers diagnosing for delirium. Results The CAM algorithm tool, as used by family physicians, demonstrated a sensitivity of 91.9% and a specificity of 100.0%, with a PPV of 100.0% and an NPV of 90.6%. Interrater agreement between the family physicians and the psychiatrists was good (Cohen's Kappa = 0.91, p Conclusions Family physicians performed well when diagnosing delirium in elderly hospitalized Thai patients using the Thai version of the CAM algorithm, showing that this measurement tool is suitable for use by non-psychiatrically trained personnel, being short, quick, and easy to administer. However, proper training on use of the algorithm is required.

  18. Discoloration of various CAD/CAM blocks after immersion in coffee

    Directory of Open Access Journals (Sweden)

    Sasipin Lauvahutanon

    2017-02-01

    Full Text Available Objectives This study evaluated color differences (ΔEs and translucency parameter changes (ΔTPs of various computer-aided design/computer-aided manufacturing (CAD/CAM blocks after immersion in coffee. Materials and Methods Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L*a*b* values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6. The ΔEs and ΔTPs of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05. The ΔEs after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results After one month in coffee, ΔEs of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ΔTPs decreased. The ANOVA of ΔEs and ΔTPs revealed significant differences in two main factors, immersion periods and media, and their interaction except for ΔEs of TEL (Telio CAD, Ivoclar Vivadent. The ΔEs significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC. There was no significant correlation between ΔEs and water sorption or solubility in water. Conclusions The ΔEs of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

  19. Input torque balancing using a cam-based centrifugal pendulum: design optimization and robustness

    Science.gov (United States)

    Demeulenaere, B.; Spaepen, P.; De Schutter, J.

    2005-05-01

    In a companion paper (Input torque balancing using a cam-based centrifugal pendulum: design procedure and example, J. Sound Vib.), the cam-based centrifugal pendulum (CBCP) was introduced as a simple, cam-based, input torque balancing mechanism. The differential equation that governs the CBCP cam design was derived and a methodology for solving it was developed. Furthermore, in a design example, the CBCP was applied to balance the input torque of a high-speed cam-follower mechanism, driving the sley of a weaving loom. The present paper firstly shows how the design parameters for this particular design example can be optimized, so as to obtain a compact and technologically feasible mechanism. The formulation of the optimization problem is based on a parameterization of the CBCP rotor and coupler shape. Because of its nonconvex nature, the optimization problem is solved using a multi-start sequential quadratic programming (SQP) approach. A design chart, based on an exhaustive analysis, is introduced which (i) allows the designer to perform the design optimization in a quick and approximative way, and (ii) gives considerable insight into the behavior of the SQP-algorithm. Secondly, the CBCP is applied to an industrial case study, that is, a weaving loom. The robustness of the CBCP is illustrated by showing that input torque balancing solely the sley movement enhances the overall dynamic machine behavior, despite the presence of the non-balanced shed motion. A particular contribution of this part is the determination of the weaving loom regime behavior in the frequency domain, an approach which is believed to be novel in mechanism literature.

  20. Discoloration of various CAD/CAM blocks after immersion in coffee.

    Science.gov (United States)

    Lauvahutanon, Sasipin; Shiozawa, Maho; Takahashi, Hidekazu; Iwasaki, Naohiko; Oki, Meiko; Finger, Werner J; Arksornnukit, Mansuang

    2017-02-01

    This study evaluated color differences (ΔEs) and translucency parameter changes (ΔTPs) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L(*)a(*)b(*) values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ΔEs and ΔTPs of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05). The ΔEs after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. After one month in coffee, ΔEs of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ΔTPs decreased. The ANOVA of ΔEs and ΔTPs revealed significant differences in two main factors, immersion periods and media, and their interaction except for ΔEs of TEL (Telio CAD, Ivoclar Vivadent). The ΔEs significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ΔEs and water sorption or solubility in water. The ΔEs of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

  1. Discoloration of various CAD/CAM blocks after immersion in coffee

    Science.gov (United States)

    Lauvahutanon, Sasipin; Shiozawa, Maho; Iwasaki, Naohiko; Oki, Meiko; Finger, Werner J.; Arksornnukit, Mansuang

    2017-01-01

    Objectives This study evaluated color differences (ΔEs) and translucency parameter changes (ΔTPs) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Materials and Methods Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L*a*b* values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ΔEs and ΔTPs of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05). The ΔEs after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results After one month in coffee, ΔEs of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ΔTPs decreased. The ANOVA of ΔEs and ΔTPs revealed significant differences in two main factors, immersion periods and media, and their interaction except for ΔEs of TEL (Telio CAD, Ivoclar Vivadent). The ΔEs significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ΔEs and water sorption or solubility in water. Conclusions The ΔEs of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed. PMID:28194359

  2. Cam Deformity and Acetabular Dysplasia as Risk Factors for Hip Osteoarthritis.

    Science.gov (United States)

    Saberi Hosnijeh, Fatemeh; Zuiderwijk, Maria E; Versteeg, Mathijs; Smeele, Hieronymus T W; Hofman, Albert; Uitterlinden, André G; Agricola, Rintje; Oei, Edwin H G; Waarsing, Jan H; Bierma-Zeinstra, Sita M; van Meurs, Joyce B J

    2017-01-01

    Cam deformity and acetabular dysplasia have been recognized as relevant risk factors for hip osteoarthritis (OA) in a few prospective studies with limited sample sizes. To date, however, no evidence is available from prospective studies regarding whether the magnitude of these associations differs according to sex, body mass index (BMI), and age. Participants in the Rotterdam Study cohort including men and women ages 55 years or older without OA at baseline (n = 4,438) and a mean follow-up of 9.2 years were included in the study. Incident radiographic OA was defined as a Kellgren/Lawrence grade of ≥2 or a total hip replacement at follow-up. Alpha and center-edge angles were measured to determine the presence of cam deformity and acetabular dysplasia/pincer deformity, respectively. Odds ratios (ORs) were calculated to assess the associations between both deformities and the development of OA. Subjects with cam deformity (OR 2.11, 95% confidence interval [95% CI] 1.55-2.87) and those with acetabular dysplasia (OR 2.19, 95% CI 1.50-3.21) had a 2-fold increased risk of developing OA compared with subjects without deformity, while pincer deformity did not increase the risk of OA. Stratification analyses showed that the associations of cam deformity and acetabular dysplasia with OA were driven by younger individuals, whereas BMI did not influence the associations. Female sex appears to modify the risk of hip OA related to acetabular dysplasia. Individuals with cam deformity and those with acetabular dysplasia are predisposed to OA; these associations were independent of other well-known risk factors. Interestingly, both deformities predisposed to OA only in relatively young individuals. Therefore, early identification of these conditions is important. © 2016, American College of Rheumatology.

  3. Integrated device architectures for electrochromic devices

    Energy Technology Data Exchange (ETDEWEB)

    Frey, Jonathan Mack; Berland, Brian Spencer

    2015-04-21

    This disclosure describes systems and methods for creating monolithically integrated electrochromic devices which may be a flexible electrochromic device. Monolithic integration of thin film electrochromic devices may involve the electrical interconnection of multiple individual electrochromic devices through the creation of specific structures such as conductive pathway or insulating isolation trenches.

  4. EpCAM aptamer-functionalized mesoporous silica nanoparticles for efficient colon cancer cell-targeted drug delivery.

    Science.gov (United States)

    Xie, Xiaodong; Li, Fengqiao; Zhang, Huijuan; Lu, Yusheng; Lian, Shu; Lin, Hang; Gao, Yu; Jia, Lee

    2016-02-15

    Targeted delivery of anticancer agents by functional nanoparticles is an attractive strategy to increase their therapeutic efficacy while reducing toxicity. In this work, doxorubicin (DOX)-loaded mesoporous silica nanoparticles (MSNs) were modified with aptamer (Ap) against the epithelial cell adhesion molecule (EpCAM) for targeted delivery of DOX to colon cancer cells. These nanoparticles (Ap-MSN-DOX) were characterized by particle size, zeta potential, aptamer conjugation efficiency, drug encapsulation efficiency, and drug release properties. The in vitro cell recognition, cellular uptake, EpCAM protein inhibition efficiency, and cytotoxicity of Ap-MSN-DOX were also studied. Results demonstrated that EpCAM conjugation increased binding of Ap-MSN-DOX to EpCAM over-expressing SW620 colon cancer cells but not EpCAM-negative Ramos cells, resulting in enhanced cellular uptake and increased cytotoxicity of the DOX in SW620 cells when compared to non-Ap-modified nanoparticles (MSN-DOX). Additionally, Ap-MSN-DOX exhibited significant inhibition effects on the expression of EpCAM on SW620 cells. These results suggested that Ap-MSN-DOX has the potential for the targeted delivery of therapeutic agents into EpCAM positive colon cancer cells to improve therapeutic index while reducing side effects.

  5. Bilgisayar destekli diş hekimliği ve güncel CAD/CAM sistemleri

    Directory of Open Access Journals (Sweden)

    Gözde Çelik

    2013-01-01

    Full Text Available

    CAD/CAM systems (computer aided design/computer aided manufacturing has been used in dentistry since 1987. In the past 25 years, development of various high quality chairside and laboratory CAD/CAM systems has been continued with the progress of technology. This article describes currently used CAD/CAM systems.

    Keywords: Dental, CAD/CAM systems.

     

    ÖZET

    CAD/CAM sistemleri (bilgisayar destekli tasarım/bilgisayar destekli üretim diş hekimliğinde 1987 yılından beri kullanılmaktadır. Son 25 yılda teknolojinin de ilerlemesiyle üstün özellikte çeşitli klinik ve laboratuvar CAD/CAM sistemleri geliştirilmeye devam etmektedir. Bu makalede günümüzde kullanılan CAD/CAM sistemleri anlatılmaktadır.

  6. Concurrent Complementary and Alternative Medicine CAM and Conventional Rehabilitation Therapy in the Management of Children with Developmental Disorders

    Directory of Open Access Journals (Sweden)

    Soo Yeon Kim

    2013-01-01

    Full Text Available Background. We investigated the concurrent use of conventional rehabilitations and complementary and alternative medicine (CAM therapies for the long-term management of children with developmental disorders (DDs. Methods. The parents or caregivers of 533 children with DDs (age range, 1–19 years who visited the rehabilitation centers were surveyed using in depth face-to-face interviews. Results. Of the 533 patients enrolled, 520 completed the questionnaire (97% response rate. A total of 292 (56% children were receiving multiple therapies, more than two conventional rehabilitations and CAM, at the time of the interview. A total of 249 (48% children reported lifetime CAM use, 23% used CAM at the time of the interview, and 62% of the patients planned to use CAM therapy in the future. Conventional rehabilitation therapies used at the time of the interview included physical therapy (30%, speech therapy (28%, and occupational therapy (19%, and the CAM therapies included herbal medicine (5% and acupuncture or moxibustion (3%. The respondents indicated that in the future they planned to use acupuncture or moxibustion (57%, occupational therapy (18%, cognitive behavioral therapy (16%, speech therapy (10%, and physical therapy (8%. Conclusion. Concurrent management as conventional rehabilitations and CAM therapies is widely used by children with DDs.

  7. A focus Group Study of Medical Students’ Views of an Integrated Complementary and Alternative Medicine (CAM Curriculum: Students Teaching Teachers

    Directory of Open Access Journals (Sweden)

    Désirée Lie, M.D

    2008-01-01

    Full Text Available Background: Student views of new curricula can shape training outcomes. This qualitative study elicited student opinions of CAM instruction to examine and distill best strategies.Methods: 49 second, third and fourth year students participated in focus groups using a predefined question route. Interviews were audio taped and transcribed.Results: Students successfully differentiated CAM curricula from other academic content and were supportive of a longitudinal integrated approach. They had positive disposition toward CAM use for themselves but this did not necessarily translate into patient recommendations. They agreed that goals of the CAM curriculum should center on awareness of patient use and evidence and information relevant to clinical practice. They advocated a case-based, hands-on, experiential strategy vs lectures. Students proposed greater institutional commitment to strengthen curricular effectiveness. The majority did not intend to practice CAM modalities but valued skills to assess them. Patient-centeredness was recognized. As training progressed, students exhibited a growing tendency to evaluate CAM efficacy, and therefore value, exclusively according to evidence.Conclusions: In-depth student input allowed examination of the effectiveness of a CAM curriculum,permitting improvement and assessment of program effectiveness.

  8. Information-seeking behavior in complementary and alternative medicine (CAM): an online survey of faculty at a health sciences campus.

    Science.gov (United States)

    Owen, David J; Fang, Min-Lin E

    2003-07-01

    The amount of reliable information available for complementary and alternative medicine (CAM) is limited, and few authoritative resources are available. The objective is to investigate the information-seeking behavior of health professionals seeking CAM information. Data were gathered using a Web-based questionnaire made available to health sciences faculty affiliated with the University of California, San Francisco. The areas of greatest interest were herbal medicine (67%), relaxation exercises (53%), and acupuncture (52%). About half the respondents perceived their CAM searches as being only partially successful. Eighty-two percent rated MEDLINE as a useful resource, 46% personal contacts with colleagues, 46% the Web, 40% journals, and 20% textbooks. Books and databases most frequently cited as useful had information about herbs. The largest group of respondents was in internal medicine (26%), though 15% identified their specialties as psychiatry, psychology, behavioral medicine, or addiction medicine. There was no correlation between specialty and patterns of information-seeking behavior. Sixty-six percent expressed an interest in learning more about CAM resources. Health professionals are frequently unable to locate the CAM information they need, and the majority have little knowledge of existing CAM resources, relying instead on MEDLINE. Medical librarians need to educate health professionals in the identification and use of authoritative CAM resources.

  9. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-09-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Implant-supported fixed dental prostheses with CAD/CAM-fabricated porcelain crown and zirconia-based framework.

    Science.gov (United States)

    Takaba, Masayuki; Tanaka, Shinpei; Ishiura, Yuichi; Baba, Kazuyoshi

    2013-07-01

    Recently, fixed dental prostheses (FDPs) with a hybrid structure of CAD/CAM porcelain crowns adhered to a CAD/CAM zirconia framework (PAZ) have been developed. The aim of this report was to describe the clinical application of a newly developed implant-supported FDP fabrication system, which uses PAZ, and to evaluate the outcome after a maximum application period of 36 months. Implants were placed in three patients with edentulous areas in either the maxilla or mandible. After the implant fixtures had successfully integrated with bone, gold-platinum alloy or zirconia custom abutments were first fabricated. Zirconia framework wax-up was performed on the custom abutments, and the CAD/CAM zirconia framework was prepared using the CAD/CAM system. Next, wax-up was performed on working models for porcelain crown fabrication, and CAD/CAM porcelain crowns were fabricated. The CAD/CAM zirconia frameworks and CAD/CAM porcelain crowns were bonded using adhesive resin cement, and the PAZ was cemented. Cementation of the implant superstructure improved the esthetics and masticatory efficiency in all patients. No undesirable outcomes, such as superstructure chipping, stomatognathic dysfunction, or periimplant bone resorption, were observed in any of the patients. PAZ may be a potential solution for ceramic-related clinical problems such as chipping and fracture and associated complicated repair procedures in implant-supported FDPs.

  11. L1CAM Binds ErbB Receptors through Ig-Like Domains Coupling Cell Adhesion and Neuregulin Signalling

    Science.gov (United States)

    Grijota-Martinez, Carmen; Lakomá, Jarmila; Baars, Sigrid; Garcia-Alonso, Luis; Cabedo, Hugo

    2012-01-01

    During nervous system development different cell-to-cell communication mechanisms operate in parallel guiding migrating neurons and growing axons to generate complex arrays of neural circuits. How such a system works in coordination is not well understood. Cross-regulatory interactions between different signalling pathways and redundancy between them can increase precision and fidelity of guidance systems. Immunoglobulin superfamily proteins of the NCAM and L1 families couple specific substrate recognition and cell adhesion with the activation of receptor tyrosine kinases. Thus it has been shown that L1CAM-mediated cell adhesion promotes the activation of the EGFR (erbB1) from Drosophila to humans. Here we explore the specificity of the molecular interaction between L1CAM and the erbB receptor family. We show that L1CAM binds physically erbB receptors in both heterologous systems and the mammalian developing brain. Different Ig-like domains located in the extracellular part of L1CAM can support this interaction. Interestingly, binding of L1CAM to erbB enhances its response to neuregulins. During development this may synergize with the activation of erbB receptors through L1CAM homophilic interactions, conferring diffusible neuregulins specificity for cells or axons that interact with the substrate through L1CAM. PMID:22815787

  12. Astrocyte-specific disruption of SynCAM1 signaling results in ADHD-like behavioral manifestations.

    Directory of Open Access Journals (Sweden)

    Ursula S Sandau

    Full Text Available SynCAM1 is an adhesion molecule involved in synaptic differentiation and organization. SynCAM1 is also expressed in astroglial cells where it mediates astrocyte-to astrocyte and glial-neuronal adhesive communication. In astrocytes, SynCAM1 is functionally linked to erbB4 receptors, which are involved in the control of both neuronal/glial development and mature neuronal and glial function. Here we report that mice carrying a dominant-negative form of SynCAM1 specifically targeted to astrocytes (termed GFAP-DNSynCAM1 mice exhibit disrupted diurnal locomotor activity with enhanced and more frequent episodes of activity than control littermates during the day (when the animals are normally sleeping accompanied by shorter periods of rest. GFAP-DNSynCAM1 mice also display high levels of basal activity in the dark period (the rodent's awake/active time that are attenuated by the psychostimulant D,L-amphetamine, and reduced anxiety levels in response to both avoidable and unavoidable provoking stimuli. These results indicate that disruption of SynCAM1-dependent astroglial function results in behavioral abnormalities similar to those described in animals model of attention-deficit hyperactive disorder (ADHD, and suggest a hitherto unappreciated contribution of glial cells to the pathophysiology of this disorder.

  13. Laser device

    Science.gov (United States)

    Scott, Jill R.; Tremblay, Paul L.

    2007-07-10

    A laser device includes a target position, an optical component separated a distance J from the target position, and a laser energy source separated a distance H from the optical component, distance H being greater than distance J. A laser source manipulation mechanism exhibits a mechanical resolution of positioning the laser source. The mechanical resolution is less than a spatial resolution of laser energy at the target position as directed through the optical component. A vertical and a lateral index that intersect at an origin can be defined for the optical component. The manipulation mechanism can auto align laser aim through the origin during laser source motion. The laser source manipulation mechanism can include a mechanical index. The mechanical index can include a pivot point for laser source lateral motion and a reference point for laser source vertical motion. The target position can be located within an adverse environment including at least one of a high magnetic field, a vacuum system, a high pressure system, and a hazardous zone. The laser source and an electro-mechanical part of the manipulation mechanism can be located outside the adverse environment. The manipulation mechanism can include a Peaucellier linkage.

  14. The prevalence of cam-type deformity of the hip joint: a survey of 4151 subjects of the Copenhagen Osteoarthritis Study

    DEFF Research Database (Denmark)

    Gosvig, K.K.; Jacobsen, S.; Sonne-Holm, S.

    2008-01-01

    . The relationships between cam malformation and self-reported hip pain were evaluated, and the relative importance of known risk factors for cam malformation estimated. RESULTS: We found a pronounced sex-related difference in cam-deformity distribution. The overall prevalence of cam deformity was approximately 17......% in men and 4% in women. The distribution of cam deformity was unaltered in subjects with normal joint-space width or other features of hip-joint degeneration. We found no significant association with self-reported hip pain, nor did we find any relative importance of possible risk factors for hip...

  15. Enhanced in vitro antiproliferative effects of EpCAM antibody-functionalized paclitaxel-loaded PLGA nanoparticles in retinoblastoma cells

    Science.gov (United States)

    Mitra, Moutushy; Misra, Ranjita; Harilal, Anju; Sahoo, Sanjeeb K

    2011-01-01

    Background To specifically deliver paclitaxel (PTX) to retinoblastoma (RB) cells, the anionic surface-charged poly(lactic-co-glycolic acid) (PLGA) NPs loaded with paclitaxel were conjugated with epithelial cell adhesion molecule (EpCAM) antibody for enhancing site-specific intracellular delivery of paclitaxel against EpCAM overexpressing RB cells. Methods PTX-loaded PLGA NPs were prepared by the oil-in-water single emulsion solvent evaporation method, and the PTX content in NPs was estimated by the reverse phase isocratic mode of high performance liquid chromatography. Ethyl-3-[3-dimethylaminopropyl] carbodiimide hydrochloride/N-hydroxysuccinimide chemistry was employed for the covalent attachment of monoclonal EpCAM antibody onto the NP surface. In vitro cytotoxicity of native PTX, unconjugated PTX-loaded NPs (PTX-NPs), and EpCAM antibody-conjugated PTX-loaded nanoparticles (PTX-NP-EpCAM) were evaluated on a Y79 RB cell line by a dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, while cellular apoptosis, cysteinyl-aspartic acid protease (caspase)-3 activation, Poly (adenosine diphosphate-ribose) polymerase (PARP) cleavage, and cell-cycle arrest were quantified by flow cytometry. By employing flow cytometry and fluorescence image analyses, the extent of cellular uptake was comparatively evaluated. Results PTX-NP-EpCAM had superior antiproliferation activity, increased arrested cell population at the G2-M phase, and increased activation of caspase-3, followed by PARP cleavage in parallel with the induction of apoptosis. Increased uptake of PTX-Np-EpCAM by the cells suggests that they were mainly taken up through EpCAM mediated endocytosis. Conclusions EpCAM antibody-functionalized biodegradable NPs for tumor-selective drug delivery and overcoming drug resistance could be an efficient therapeutic strategy for retinoblastoma treatment. PMID:22065926

  16. Differential effects of human L1CAM mutations on complementing guidance and synaptic defects in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Sirisha Kudumala

    Full Text Available A large number of different pathological L1CAM mutations have been identified that result in a broad spectrum of neurological and non-neurological phenotypes. While many of these mutations have been characterized for their effects on homophilic and heterophilic interactions, as well as expression levels in vitro, there are only few studies on their biological consequences in vivo. The single L1-type CAM gene in Drosophila, neuroglian (nrg, has distinct functions during axon guidance and synapse formation and the phenotypes of nrg mutants can be rescued by the expression of human L1CAM. We previously showed that the highly conserved intracellular FIGQY Ankyrin-binding motif is required for L1CAM-mediated synapse formation, but not for neurite outgrowth or axon guidance of the Drosophila giant fiber (GF neuron. Here, we use the GF as a model neuron to characterize the pathogenic L120V, Y1070C, C264Y, H210Q, E309K and R184Q extracellular L1CAM missense mutations and a L1CAM protein with a disrupted ezrin-moesin-radixin (ERM binding site to investigate the signaling requirements for neuronal development. We report that different L1CAM mutations have distinct effects on axon guidance and synapse formation. Furthermore, L1CAM homophilic binding and signaling via the ERM motif is essential for axon guidance in Drosophila. In addition, the human pathological H210Q, R184Q and Y1070C, but not the E309K and L120V L1CAM mutations affect outside-in signaling via the FIGQY Ankyrin binding domain which is required for synapse formation. Thus, the pathological phenotypes observed in humans are likely to be caused by the disruption of signaling required for both, guidance and synaptogenesis.

  17. What Are the Results of Surgical Treatment of Hip Dysplasia With Concomitant Cam Deformity?

    Science.gov (United States)

    Goronzy, Jens; Franken, Lea; Hartmann, Albrecht; Thielemann, Falk; Postler, Anne; Paulus, Tobias; Günther, Klaus-Peter

    2017-04-01

    Periacetabular osteotomy (PAO) is a reliable procedure to correct the deficient acetabular coverage in hips with developmental dysplasia. It is unclear how the presence of additional femoral cam-type deformity might influence the clinical and radiographic treatment results of PAO. (1) Are there differences in clinical scores (WOMAC, EQ-5D) and examination findings (impingement sign) or radiographic measures of acetabular orientation and head sphericity after PAO for isolated acetabular dysplasia when compared with the combined pathology of dysplasia and additional femoral cam deformity? (2) Are these clinical and radiographic findings after combined surgical therapy for additional cam deformity influenced by different pathology-adjusted surgical techniques? From July 2005 to December 2010, 86 patients (106 hips) underwent PAO for hip dysplasia. Surgical and outcome data were prospectively collected and retrospectively reviewed in a comparative observational study. Indications for surgery were a lateral center-edge angle less than 25° and hip pain for at least 6 months. The contraindications for surgery were advanced radiographic osteoarthritis (Kellgren-Lawrence Grade 3), incongruency of joint space, and patient age > 50 years. Depending on preoperative hip ROM, impingement test, and presence of a radiographically visible cam deformity, treatment allocation was performed: Group I: isolated PAO in patients without symptomatic asphericity, Group IIa: PAO with subsequent osteochondroplasty through arthrotomy for patients with symptomatic cam deformity and no labrochondral pathology, and Group IIb: arthroscopically assisted osteochondroplasty and additional labrochondral repair with subsequent PAO when patients had labrochondral lesions in addition to a symptomatic cam deformity. Clinical outcome (impingement test, EQ-5D, WOMAC) as well as radiographic parameters (lateral center-edge angle, crossover sign, alpha angle, osteoarthritis grade) were obtained after a mean

  18. In God and CAM we trust. Religious faith and use of complementary and alternative medicine (CAM) in a nationwide cohort of women treated for early breast cancer.

    Science.gov (United States)

    Pedersen, Christina Gundgaard; Christensen, Søren; Jensen, Anders Bonde; Zachariae, Robert

    2013-09-01

    Turning to faith in God or a higher spiritual power is a common way of coping with life-threatening disease such as cancer. Little, however, is known about religious faith among cancer patients in secular societies. The present study aimed at exploring the prevalence of religious faith among Danish breast cancer patients and at identifying whether socio-demographic, pre-cancer health status, clinical, and health behavior characteristics, including their use of complementary and alternative medicine (CAM), were associated with their degree of faith. Information on faith in God or a higher spiritual power and use of CAM was provided by a nationwide sample of 3,128 recurrence-free Danish women who had received surgery for early-stage breast cancer 15-16 months earlier. Socio-demographic, clinical, and health status variables were obtained from national longitudinal registries, and health behaviors had been assessed at 3-4 months post-surgery. Of the women, 47.3% reported a high degree of faith (unambiguous believers), 35.9% some degree of faith (ambiguous believers), while the remaining 16.8% were non-believers. Unambiguous believers were more likely than ambiguous believers to experience their faith as having a positive impact on their disease and their disease-related quality-of-life. When compared to non-believers, unambiguous believers were also older, had poorer physical function, and were more frequent users of CAM, and more inclined to believe that their use of CAM would have a beneficial influence on their cancer. Disease- and treatment-related variables were unrelated to faith. While overall religious faith appears equally prevalent among Danish and US breast cancer patients, the majority of Danish breast cancer patients experienced ambiguous faith, whereas the majority of US patients have been found to express unambiguous faith. Our results suggest that future studies may benefit from exploring the role of faith for health behaviors, adherence to

  19. Calcium Sulfate Vein Observations at Yellowknife Bay using ChemCam on the Curiosity Rover

    Science.gov (United States)

    Clegg, S. M.; Mangold, N.; Nachon, M.; Le Mouelic, S.; Ollila, A.; Vaniman, D. T.; Kah, L. C.; Dromart, G.; Bridges, J.; Rice, M. S.; Wellington, D. F.; Bell, J. F.; Anderson, R. B.; Clark, B. C.; Cousin, A.; Forni, O.; Lasue, J.; Schröder, S.; Meslin, P.; Dyar, M. D.; Blaney, D. L.; Maurice, S.; Wiens, R. C.; Team, M.

    2013-12-01

    The Mars Science Laboratory Curiosity rover completed its traverse from the Bradbury landing site into Yellowknife Bay (YKB) on sol 125, where it spent ~175 sols. The YKB region is characterized as a fluvio-lacustrine depositional environment. The entire Curiosity payload was used to thoroughly investigate parts of YKB from which significant geochemical observations were made, including the identification of anhydrite and hydrated calcium sulfate. The Curiosity ChemCam package consists of a remote Laser-Induced Breakdown Spectrometer (LIBS) and a Remote Micro-Imager (RMI). LIBS is essentially an elemental analysis micro-probe capable of 300 - 550 μm spatial resolution from 1.5 - 7.0 m standoff distance from the Curiosity mast. The RMI records context images that have a resolution of 40 μrad, which corresponds to 120 μm at 3 meters. The ChemCam instrument recorded many calcium rich geochemical features as it descended ~18 m into YKB. Many light-toned veins became apparent with the ChemCam RMI and Mastcam once Curiosity entered YKB. The ChemCam LIBS instrument is uniquely capable of distinctly probing the elemental composition of these vein structures separately from the host rock. LIBS demonstrated that the white vein material was dominated by CaSO4, while the host rock had relatively low SO3 compositions. The ChemCam instrument can also qualitatively detect H, presumably due to H2O, in many samples. While some of these veins contained no H signature beyond the ubiquitous small amount of H on rock surfaces and in soils, some of the veins contained various amounts of H as a function of depth indicating that some of the samples were either bassanite or gypsum. Mastcam spectral hydration surveys detect evidence of hydration that is consistent with (but not a unique indicator of) the presence of gypsum in some, but not all, of the veins. The CheMin X-ray diffraction instrument identified both anhydrite and bassanite in the matrix of a mudstone unit but did not detect

  20. The SuperCam Remote-Sensing Instrument Suite for the Mars 2020 Rover Mission

    Science.gov (United States)

    Wiens, R. C.; Maurice, S.; Clegg, S. M.; Rull, F.; Sharma, S. K.; Anderson, R. B.; Beyssac, O.; Bonal, L.; DeFlores, L. P.; Dromart, G.; Fischer, W. W.; Forni, O.; Gasnault, O.; Grotzinger, J. P.; Johnson, J. R.; Martinez-Frias, J.; Mangold, N.; McLennan, S. M.; Montmessin, F.

    2015-12-01

    The SuperCam remote-sensing instrument suite in development for the Mars 2020 rover represents a significant advance from its precursor, ChemCam, by adding Raman spectroscopy (to 12 m distance) and visible and near-infrared (VISIR) reflectance spectroscopy. For Raman spectroscopy the LIBS Nd:YAG laser is frequency-doubled to 532 nm (green Raman). A transmission spectrometer with an intensified CCD covers 150-4400 cm-1 spectral range at a resolution of 10 cm-1. The system is adjustably time-gated, removing much of the mineral fluorescence from the Raman spectra and also facilitating time-resolved fluorescence studies. The infrared range covers 1.3-2.6 microns in addition to the existing 400-840 nm range on ChemCam. Additional upgrades include doubling the LIBS resolution in the 535-860 nm range and adding color to the Remote Micro-Imager (RMI), which is the highest resolution remote imager on the rover. A large-scale effort is being applied to the on-board standards, being led by U. Valladolid in Spain, with targets contributed by many institutions. The number of geological targets will be increased from 8 (on ChemCam) to 22, planned to include end-member plagioclase feldspars, hi- and low-Ca pyroxene, olivines, several fine-grained basalts, hematite, jarosite, carbonates, apatite, and several synthetic targets doped with trace elements. Three Spectralon targets are planned for IR calibration and several color bands for the RMI. All but the Spectralon and color bands should be available for LIBS calibration, and many are also being designed for Raman and VISIR calibration. For LIBS this collection of standards will significantly improve the accuracy relative to ChemCam; other precision improvements are anticipated to come from correcting for variable plasma temperature. The presentation will illustrate how Mars datasets will be significantly improved via this multi-technique approach and will give a first look at prototype SuperCam spectra.

  1. Medical devices: US medical device regulation.

    Science.gov (United States)

    Jarow, Jonathan P; Baxley, John H

    2015-03-01

    Medical devices are regulated by the US Food and Drug Administration (FDA) within the Center for Devices and Radiological Health. Center for Devices and Radiological Health is responsible for protecting and promoting the public health by ensuring the safety, effectiveness, and quality of medical devices, ensuring the safety of radiation-emitting products, fostering innovation, and providing the public with accurate, science-based information about the products we oversee, throughout the total product life cycle. The FDA was granted the authority to regulate the manufacturing and marketing of medical devices in 1976. It does not regulate the practice of medicine. Devices are classified based on complexity and level of risk, and "pre-1976" devices were allowed to remain on the market after being classified without FDA review. Post-1976 devices of lower complexity and risk that are substantially equivalent to a marketed "predicate" device may be cleared through the 510(k) premarket notification process. Clinical data are typically not needed for 510(k) clearance. In contrast, higher-risk devices typically require premarket approval. Premarket approval applications must contain data demonstrating reasonable assurance of safety and efficacy, and this information typically includes clinical data. For novel devices that are not high risk, the de novo process allows FDA to simultaneously review and classify new devices. Devices that are not legally marketed are permitted to be used for clinical investigation purposes in the United States under the Investigational Device Exemptions regulation.

  2. Prognostic value and clinicopathologic characteristics of L1 cell adhesion molecule (L1CAM) in a large series of vulvar squamous cell carcinomas.

    Science.gov (United States)

    Trietsch, Marjolijn D; Oonk, Maaike H M; Hawinkels, Lukas J A C; Bor, Rosalie; van Eendenburg, Jaap D H; Ivanova, Zina; Peters, Alexander A W; Nijman, Hans W; Gaarenstroom, Katja N; Bosse, Tjalling

    2016-05-03

    Vulvar cancer treatment is mostly curative, but also has high morbidity rates. In a search for markers that can identify patients at risk of metastases, we investigated the prognostic value of L1-cell adhesion molecule (L1CAM) in large series of vulvar squamous cell carcinomas (VSCCs). L1CAM promotes cell motility and is an emerging prognostic factor for metastasis in many cancer subtypes. L1CAM expression was observed at the invasive front or in spray-patterned parts of 17% of the tumours. L1CAM-positive tumours expressed vimentin more often, but L1CAM expression was not associated with TP53 or CTNNB1 mutations. Five-year survival was worse for patients with L1CAM expression (overall survival 46.1% vs 63.6%, P=.014, disease specific survival 63.8% vs 80.0%, P=.018). Multivariate analysis indicates L1CAM expression as an independent prognostic marker (HR 2.9, 95% CI 1.10-7.68). An in vitro spheroid invasion assay showed decreased invasion of L1CAM-expressing VSCC spindle cells after treatment with L1CAM-neutralising antibodies. Paraffin-embedded tumour tissue from two cohorts (N=103 and 245) of primary VSCCs were stained for L1CAM, vimentin and E-cadherin. Patients of the first cohort were tested for human papilloma virus infection and sequenced for TP53 and CTNNB1 (β-catenin) mutations. The expression of L1CAM was correlated to clinical characteristics and patient survival. This is the first study to show high L1CAM-expression at the infiltrating margin of VSCC's. L1CAM-expressing VSCCs had a significantly worse prognosis compared to L1CAM-negative tumours. The highest expression was observed in spindle-shaped cells, where it might be correlated to their invasive capacity.

  3. Epilogue to the two-part series: Measurement equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS® short forms

    Directory of Open Access Journals (Sweden)

    Jeanne A. Teresi

    2016-06-01

    Full Text Available The articles in this two-part series of Psychological Test and Assessment Modeling describe the psychometric performance and measurement equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS® short form measures in ethnically, socio-demographically diverse groups of cancer patients. Measures in eight health-related quality of life domains were evaluated: fatigue, depression, anxiety, cognition, pain, sleep, and physical and social function. State-of-the-art latent variable methods, most based on item response theory, and described in two methods overview articles in this series were used to examine differential item functioning (DIF. Findings were generally supportive of the performance of the PROMIS measures. Although use of powerful methods and large samples resulted in the identification of many items with DIF, practi-cally none were identified with high magnitude. The aggregate level impact of DIF was small, and minimal individual impact was detected. Some methodological challenges were encountered in-volving positively and negatively worded items, but most were resolved through modest item removal. Sensitivity analyses showed minimal impact of model assumption violation on the results presented. A cautionary note is the observance of a few instances of individual-level impact of DIF in the analyses of depression, anxiety, and pain, and one instance of aggregate level impact just below threshold in the analyses of physical function. Although this sample of over 5,000 individuals was diverse, ethnically, a limitation was the lack of ability to examine language groups other than Spanish and English and specific ethnic subgroups within Hispanic, Asian/Pacific Islander, and Black subsamples. Extensive qualitative and quantitative analyses were performed in the development of PROMIS item banks. These sets of analyses, performed by several teams of psychometricians, statisticians, and qualitative experts, were the

  4. Poly (ε-caprolactone nanofibrous ring surrounding a polyvinyl alcohol hydrogel for the development of a biocompatible two-part artificial cornea

    Directory of Open Access Journals (Sweden)

    Bakhshandeh H

    2011-07-01

    % when measured in the 400–800 nm wavelength range. The plasma-treated PCL nanofibrous scaffold promoted limbal stem cell adhesion and proliferation within 10 days. These results confirmed that the polymeric artificial cornea showed suitable physical properties and good biocompatibility and epithelialization ability.Keywords: two part artificial cornea, nanofibers, electrospun, poly (ε-caprolactone, polyvinyl alcohol hydrogel, limbal stem cells

  5. Carbohydrate intake, obesity, metabolic syndrome and cancer risk? A two-part systematic review and meta-analysis protocol to estimate attributability.

    Science.gov (United States)

    Sartorius, B; Sartorius, K; Aldous, C; Madiba, T E; Stefan, C; Noakes, T

    2016-01-04

    required. The final results of this two part systematic review (plus multiplicative calculations) will be published in a relevant international peer-reviewed journal. PROSPERO CRD42015023257. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Ceramicas y sistemas para restauraciones CAD-CAM: una revision.(REVISION DE TEMA)(Perspectiva general del procedimiento medico)

    National Research Council Canada - National Science Library

    Perez, Carlos Caparroso; Vargas, Jaiver Andres Duque

    2010-01-01

    En la actualidad disponemos de muchos sistemas para hacer de restauraciones indirectas libres de metal, el de mayor actualidad y uso es el denominado CAD-CAM, cuyo diseno y elaboracion son asistidas por un computador...

  7. Chipping fracture resistance of dental CAD/CAM restorative materials: Part 2. Phenomenological model and the effect of indenter type

    OpenAIRE

    Quinn, G. D.; Giuseppetti, A.A.; Hoffman, K. H.

    2014-01-01

    The edge chipping resistances of six CAD/CAM dental restoration materials are analyzed and correlated to other mechanical properties. A new quadratic relationship that is based on a phenomenological model is presented.

  8. Development of bioluminescent chick chorioallantoic membrane (CAM) models for primary pancreatic cancer cells: a platform for drug testing.

    Science.gov (United States)

    Rovithi, Maria; Avan, Amir; Funel, Niccola; Leon, Leticia G; Gomez, Valentina E; Wurdinger, Thomas; Griffioen, Arjan W; Verheul, Henk M W; Giovannetti, Elisa

    2017-03-17

    The aim of the present study was to develop chick-embryo chorioallantoic membrane (CAM) bioluminescent tumor models employing low passage cell cultures obtained from primary pancreatic ductal adenocarcinoma (PDAC) cells. Primary PDAC cells transduced with lentivirus expressing Firefly-luciferase (Fluc) were established and inoculated onto the CAM membrane, with >80% engraftment. Fluc signal reliably correlated with tumor growth. Tumor features were evaluated by immunohistochemistry and genetic analyses, including analysis of mutations and mRNA expression of PDAC pivotal genes, as well as microRNA (miRNA) profiling. These studies showed that CAM tumors had histopathological and genetic characteristic comparable to the original tumors. We subsequently tested the modulation of key miRNAs and the activity of gemcitabine and crizotinib on CAM tumors, showing that combination treatment resulted in 63% inhibition of tumor growth as compared to control (p testing, providing insights on molecular mechanisms underlying antitumor activity of new drugs/combinations.

  9. FlashCam: a fully-digital camera for the medium-sized telescopes of the Cherenkov Telescope Array

    CERN Document Server

    Pühlhofer, G; Bernhard, S; Capasso, M; Diebold, S; Eisenkolb, F; Florin, D; Föhr, C; Funk, S; Gadola, A; Garrecht, F; Hermann, G; Jung, I; Kalekin, O; Kalkuhl, C; Kasperek, J; Kihm, T; Lahmann, R; Manalaysay, A; Marszalek, A; Pfeifer, M; Rajda, P J; Reimer, O; Santangelo, A; Schanz, T; Schwab, T; Steiner, S; Straumann, U; Tenzer, C; Vollhardt, A; Weitzel, Q; Werner, F; Wolf, D; Zietara, K

    2015-01-01

    The FlashCam group is currently preparing photomultiplier-tube based cameras proposed for the medium-sized telescopes (MST) of the Cherenkov Telescope Array (CTA). The cameras are designed around the FlashCam readout concept which is the first fully-digital readout system for Cherenkov cameras, based on commercial FADCs and FPGAs as key components for the front-end electronics modules and a high performance camera server as back-end. This contribution describes the progress of the full-scale FlashCam camera prototype currently under construction, as well as performance results also obtained with earlier demonstrator setups. Plans towards the production and implementation of FlashCams on site are also briefly presented.

  10. IPAD 2: Advances in Distributed Data Base Management for CAD/CAM

    Science.gov (United States)

    Bostic, S. W. (Compiler)

    1984-01-01

    The Integrated Programs for Aerospace-Vehicle Design (IPAD) Project objective is to improve engineering productivity through better use of computer-aided design and manufacturing (CAD/CAM) technology. The focus is on development of technology and associated software for integrated company-wide management of engineering information. The objectives of this conference are as follows: to provide a greater awareness of the critical need by U.S. industry for advancements in distributed CAD/CAM data management capability; to present industry experiences and current and planned research in distributed data base management; and to summarize IPAD data management contributions and their impact on U.S. industry and computer hardware and software vendors.

  11. CAD/CAM method application for ear shell auto-manufacturing

    Science.gov (United States)

    Jarng, Soon Suck; Ting, Gao

    2010-01-01

    This paper presents the engineering technique of the rapid hearing aid production with a rapid shell modelling (RSM) Computer Aided Design/Manufacturing (CAD/CAM). It will be worthwhile to describe how the virtual ear shell designed with RSM from an ear impression. And the virtual ear shell model is then used as the template to manufacture the actual ear shell by a Rapid Production (RP) machine. Some detailed description of the whole processing will be given in this thesis. The CAD/CAM method processing will enhance and provide outstanding, high-quality hearing aid shell production capabilities to customers. It reduces the time and the cost of designing products and facilitates direct and indirect manufacturing by creating actual parts directly from digital input. It determines that this technique has made a large impact on hearing aid processing and fitting.

  12. Utilizing optical coherence tomography for CAD/CAM of indirect dental restorations

    Science.gov (United States)

    Chityala, Ravishankar; Vidal, Carola; Jones, Robert

    Optical Coherence Tomography (OCT) has seen broad application in dentistry including early carious lesion detection and imaging defects in resin composite restorations. This study investigates expanding the clinical usefulness by investigating methods to use OCT for obtaining three-dimensional (3D) digital impressions, which can be integrated to CAD/CAM manufacturing of indirect restorations. 3D surface topography `before' and `after' a cavity preparation was acquired by an intraoral cross polarization swept source OCT (CP-OCT) system with a Micro-Electro-Mechanical System (MEMS) scanning mirror. Image registration and segmentation methods were used to digitally construct a replacement restoration that modeled the original surface morphology of a hydroxyapatite sample. After high resolution additive manufacturing (e.g. polymer 3D printing) of the replacement restoration, micro-CT imaging was performed to examine the marginal adaptation. This study establishes the protocol for further investigation of integrating OCT with CAD/CAM of indirect dental restorations.

  13. UGS NX CAM Express在模具加工中的运用

    Institute of Scientific and Technical Information of China (English)

    普涛

    2008-01-01

    UGS NX CAM EXPRESS是UGS公司针对行业的模块化加工软件包,是专门为高级机床提供的高级CAM软件。它独立于CAD软件,不受特定CAD系统的限制,并且拥有关键的行业转换程序,可以在线访问后处理库,有利于加工数据导入,可以解决典型的CNC编程的需求。本文通过针对模具在完整的工作流环境下进行加工过程来介绍NX兴CAM Express的应用。

  14. Integrated CAD/CAM/CNC system based on STEP-NC and intelligent manufacturing

    Science.gov (United States)

    Du, Juan; Tian, Xitian; Zhang, Zhenming; Xu, Jianxin; Zhu, Mingquan

    2005-12-01

    In order to realize bi-direction exchange of information and knowledge sharing between CAD/CAM systems and CNC machines, a method of information integration was proposed based on process data model and STEP-NC neutral file. A frame of integrated CAD/CAM/CNC systems was established, and the key integration techniques including process data modeling based on XML form and automatic feature recognition were studied. Since the STEP-NC based CNC (STEP- CNC) system can undertake various intelligent functions that cannot be performed by the conventional CNC based on ISO 6983, the intelligent manufacturing functions of STEP- CNC system was also discussed. The presented methodology combining with the modern net and communication technologies provides an effective means for developing intelligent, integrated manufacturing systems for the 21 century.

  15. Cultural competency, autonomy, and spiritual conflicts related to Reiki/CAM therapies: Should patients be informed?

    Science.gov (United States)

    Arvonio, Maria Marra

    2014-02-01

    The use of complementary and alternative medicines (CAM) such as Reiki is on the rise in healthcare centers. Reiki is associated with a spirituality that conflicts with some belief systems. Catholic healthcare facilities are restricted from offering this therapy because it conflicts with the teachings of the Catholic Church. However, hospitals are offering it without disclosing the spiritual aspects of it to patients. This article will address the ethical concerns and possible legal implications associated with the present process of offering Reiki. It will address these concerns based on the Joint Commission's Standard of Cultural Competency and the ethical principles of autonomy and informed consent. A proposal will also be introduced identifying specific information which Reiki/CAM practitioners should offer to their patients out of respect of their autonomy as well as their cultural, spiritual, and religious beliefs.

  16. CIM's bridge from CADD to CAM: Data management requirements for manufacturing engineering

    Science.gov (United States)

    Ford, S. J.

    1984-01-01

    Manufacturing engineering represents the crossroads of technical data management in a Computer Integrated Manufacturing (CIM) environment. Process planning, numerical control programming and tool design are the key functions which translate information from as engineered to as assembled. In order to transition data from engineering to manufacturing, it is necessary to introduce a series of product interpretations which contain an interim introduction of technical parameters. The current automation of the product definition and the production process places manufacturing engineering in the center of CAD/CAM with the responsibility of communicating design data to the factory floor via a manufacturing model of the data. A close look at data management requirements for manufacturing engineering is necessary in order to establish the overall specifications for CADD output, CAM input, and CIM integration. The functions and issues associated with the orderly evolution of computer aided engineering and manufacturing are examined.

  17. CIM's bridge from CADD to CAM: Data management requirements for manufacturing engineering

    Science.gov (United States)

    Ford, S. J.

    1984-01-01

    Manufacturing engineering represents the crossroads of technical data management in a Computer Integrated Manufacturing (CIM) environment. Process planning, numerical control programming and tool design are the key functions which translate information from as engineered to as assembled. In order to transition data from engineering to manufacturing, it is necessary to introduce a series of product interpretations which contain an interim introduction of technical parameters. The current automation of the product definition and the production process places manufacturing engineering in the center of CAD/CAM with the responsibility of communicating design data to the factory floor via a manufacturing model of the data. A close look at data management requirements for manufacturing engineering is necessary in order to establish the overall specifications for CADD output, CAM input, and CIM integration. The functions and issues associated with the orderly evolution of computer aided engineering and manufacturing are examined.

  18. Environmental influences on CO sub 2 uptake by agaves, CAM plants with high productivities

    Energy Technology Data Exchange (ETDEWEB)

    Nobel, P.S. (Univ. of California, Los Angeles (USA))

    Agaves have long been utilized for their leaf fiber and for beverage production. As first reported in 1968 for Agave americana, they are Crassulacean Acid Metabolism (CAM) plants, for which stomatal opening and CO{sub 2} uptake occur primarily at night when the lower temperatures greatly reduce water loss. More recently, the influences of rainfall, temperature, and photosynthetically active radiation on CO{sub 2} uptake by agaves have been determined and incorporated into an Environmental Productivity Index (EPI). Nutrient effects on CO{sub 2} uptake and growth can be quantified by a Nutrient Index, which multiples EPI to account for soil element effects. Because of CAM, agaves can have high productivities in regions of moderate annual rainfall, and because of EPI, such productivity can be predicted, which augurs well for the increased future cultivation of agaves.

  19. a Study on Fracture Characteristics of the SM53C Used in the Cam Shaft

    Science.gov (United States)

    Jeon, Hyun-Bae; Song, Tae-Hoon; Park, Sung-Ho; Huh, Sun-Chul; Park, Won-Jo

    This experimental study investigates the fracture characteristics of the camshaft made with newly developed SM53C material. As part of the countermeasure, use the surface hardening heat treatment. Cam shaft which is a part of automobile engine is very essential when traveling and significant to fuel injection timing. Stiffness and efficiency are important for automobile sash which have a durability of the engine. High hardness and durability are necessary, because engine output is affected by cam shaft directly. So, high-frequency induction hardening is very important because of increasing the surface strength. The shape of hardening depth, hardened structure, hardness, and fracture characteristics of SM53C composed by carbon steel are also investigated.

  20. Prediction for Dynamic Characteristics of Ring-Plate Planetary Indexing Cam Mechanism

    Institute of Scientific and Technical Information of China (English)

    SONG Yimin; TIAN Guangcai; ZHANG Jun; LIU Mingtao; LIU Jianping

    2009-01-01

    This paper is aimed to propose an approach to predict the dynamic characteristics of ring-plate planetary indexing cam mechanism, which is a novel type of indexing mechanism that employs internal planetary transmis-sion structure. Firstly, the geometry and structure of the mechanism are discussed and the kinematic practicability is simulated with virtual prototype design. Then a 3D finite element model of the ring-plate planetary indexing cam mechanism is developed with the commercial software of MATLAB and ANSYS. Through the finite element analysis, the natural frequencies and the corresponding mode shapes are predicted in one motion cycle. On the basis of the virtual prototype design and finite element analysis, an experimental prototype is made and tested to validate the prediction of the dynamic characteristics. The agreement between experimental results and the finite element analysis testifies that the finite element model developed is applicable to the prediction of the dynamic characteris-tics of this type of mechanism.