  1. Two-component laser Doppler anemometer for measurement of velocity and turbulent shear stress near prosthetic heart valves.

    Science.gov (United States)

    Woo, Y R; Yoganathan, A P

    1985-01-01

    The velocity and turbulent shear stress measured in the immediate vicinity of prosthetic heart valves play a vital role in the design and evaluation of these devices. In the past hot wire/film and one-component laser Doppler anemometer (LDA) systems were used extensively to obtain these measurements. Hot wire/film anemometers, however, have some serious disadvantages, including the inability to measure the direction of the flow, the disturbance of the flow field caused by the probe, and the need for frequent calibration. One-component LDA systems do not have these problems, but they cannot measure turbulent shear stresses directly. Since these measurements are essential and are not available in the open literature, a two-component LDA system for measuring velocity and turbulent shear stress fields under pulsatile flow conditions was assembled under an FDA contract. The experimental methods used to create an in vitro data base of velocity and turbulent shear stress fields in the immediate vicinity of prosthetic heart valves of various designs in current clinical use are also discussed.

  2. Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

    Science.gov (United States)

    Akutsu, T; Modi, V J

    1997-10-01

    Five typical mechanical heart valves (Starr-Edwards, Björk-Shiley convexo-concave (c-c), Björk-Shiley monostrut, Bicer-Val, and St. Jude Medical) were tested in the mitral position under the pulsatile flow condition. The test program included measurements of velocity and turbulent stresses at 5 downstream locations. The study was carried out using a sophisticated cardiac simulator in conjunction with a highly sensitive 2 component laser Doppler anemometer (LDA) system. The continuous monitoring of parametric time histories revealed useful details about the complex flow and helped to establish the locations and times of the peak parameter values. Based upon the nondimensional presentation of data, the following general conclusions can be made. First, all the 5 valve designs created elevated turbulent stresses during the accelerating and peak flow phases, presenting the possibility of thromboembolism and perhaps hemolysis. Second, the difference in valve configuration seemed to affect the flow characteristics; third, the bileaflet design of the St. Jude valve appeared to create a lower turbulence stress level.

  3. Two-Component Simultaneous LDV (Laser Doppler Velocimeter) Turbulence Measurements in an Axisymmetric Nozzle Afterbody Subsonic Flow Field with a Cold, Underexpanded Supersonic Jet

    Science.gov (United States)

    1983-06-01

    Diffracted Laser Vclocimeter to Turbulence Measurement in a Subsonic Jet." AEDC- TR-76-36 (AD-A025355), May 1976. . Knott , P. and Mossey, P. "Parametric...0 . 5 I 1 8 3 ~ . ~ 306 2 3 I I O0 V = = 7 1 3 . 0 f i / s e c T t = 6 4 0 . 3 ° R SEQ ~D fiB VjF’V. V/V. IVI/V. M S / V . SJV. S ~ S

  4. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  5. Laser double Doppler flowmeter

    Science.gov (United States)

    Poffo, L.; Goujon, J.-M.; Le Page, R.; Lemaitre, J.; Guendouz, M.; Lorrain, N.; Bosc, D.

    2014-05-01

    The Laser Doppler flowmetry (LDF) is a non-invasive method for estimating the tissular blood flow and speed at a microscopic scale (microcirculation). It is used for medical research as well as for the diagnosis of diseases related to circulatory system tissues and organs including the issues of microvascular flow (perfusion). It is based on the Doppler effect, created by the interaction between the laser light and tissues. LDF measures the mean blood flow in a volume formed by the single laser beam, that penetrate into the skin. The size of this measurement volume is crucial and depends on skin absorption, and is not directly reachable. Therefore, current developments of the LDF are focused on the use of always more complex and sophisticated signal processing methods. On the other hand, laser Double Doppler Flowmeter (FL2D) proposes to use two laser beams to generate the measurement volume. This volume would be perfectly stable and localized at the intersection of the two laser beams. With FL2D we will be able to determine the absolute blood flow of a specific artery. One aimed application would be to help clinical physicians in health care units.

  6. Laser Doppler flowmetry imaging

    Science.gov (United States)

    Nilsson, Gert E.; Wardell, Karin

    1994-02-01

    A laser Doppler perfusion imager has been developed that makes possible mapping of tissue blood flow over surfaces with extensions up to about 12 cm X 12 cm. The He-Ne laser beam scans the tissue under study throughout 4096 measurement sites. A fraction of the backscattered and Doppler broadened light is detected by a photo diode positioned about 20 cm above the tissue surface. After processing, a signal that scales linearly with perfusion is stored in a computer and a color coded image of the spatial tissue perfusion is shown on a monitor. A full format scan is completed in about 4.5 minutes. Algorithms for calculating perfusion profiles and averages as well as substraction of one image from another, form an integral part of the system data analysis software. The perfusion images can also be exported to other software packages for further processing and analysis.

  7. Scanning laser Doppler vibrometry

    OpenAIRE

    2016-01-01

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from Polytec Inc. – was acquired and put to operation in October 2014, paid by a sub-donation of DKK 1,5 mill. of the total VILLUM CASMaT grant. Opening possibilities of measuring complicated vibration shapes...

  8. Holographic laser Doppler ophthalmoscopy

    CERN Document Server

    Simonutti, Manuel; Sahel, J A; Gross, Michel; Samson, Benjamin; Magnain, Caroline; Atlan, Michael; 10.1364/OL.35.001941

    2010-01-01

    We report laser Doppler ophthalmoscopic fundus imaging in the rat eye with near-IR heterodyne holography. Sequential sampling of the beat of the reflected radiation against a frequency-shifted optical local oscillator is made onto an array detector. Wide-field maps of fluctuation spectra in the 10 Hz to 25 kHz band exhibit angiographic contrasts in the retinal vascular tree without requirement of an exogenous marker.

  9. Laser Doppler Imaging of Microflow

    CERN Document Server

    Gross, Michel; Leng, Jacques

    2013-01-01

    We report a pilot study with a wide-field laser Doppler detection scheme used to perform laser Doppler anemometry and imaging of particle seeded microflow. The optical field carrying the local scatterers (particles) dynamic state, as a consequence of momentum transfer at each scattering event, is analyzed in the temporal frequencies domain. The setup is based on heterodyne digital holography, which is used to map the scattered field in the object plane at a tunable frequency with a multipixel detector. We show that wide-field heterodyne laser Doppler imaging can be used for quantitative microflow diagnosis; in the presented study, maps of the first-order moment of the Doppler frequency shift are used as a quantitative and directional estimator of the Doppler signature of particles velocity.

  10. Novel instantaneous laser Doppler velocimeter.

    Science.gov (United States)

    Avidor, J M

    1974-02-01

    A laser Doppler velocimeter capable of directly measuring instantaneous velocities is described. The new LDV uses a novel detection technique based on the utilization of a static slightly defocused spherical Fabry-Perot interferometer used in conjunction with a special mask for the detection of instantaneous Doppler frequency shifts. The essential characteristics of this LDV are discussed, and such a system recently developed is described. Results of turbulent flow measurements show good agreement with data obtained using hot wire anemometry.

  11. Speckles in laser doppler perfusion imaging

    NARCIS (Netherlands)

    Rajan, Vinayakrishnan

    2007-01-01

    Laser Doppler Flowmetry (LDF) is a noninvasive diagnostic method to measure blood flow in tissue [1]. The technique is based on measuring the Doppler shift induced by moving red blood cells to the illuminating coherent light. A laser Doppler instrument often gives output signals related to the flux,

  12. Laser Doppler velocimetry using a modified computer mouse

    Science.gov (United States)

    Zaron, Edward D.

    2016-10-01

    A computer mouse has been modified for use as a low-cost laser Doppler interferometer and used to measure the two-component fluid velocity of a flowing soap film. The mouse sensor contains two vertical cavity surface emitting lasers, photodiodes, and signal processing hardware integrated into a single package, approximately 1 cm2 in size, and interfaces to a host computer via a standard USB port. Using the principle of self-mixing interferometry, whereby laser light re-enters the laser cavity after being scattered from a moving target, the Doppler shift and velocity of scatterers dispersed in the flow are measured. Observations of the boundary layer in a turbulent soap film channel flow demonstrate the capabilities of the sensor.

  13. Fiber optic laser Doppler anemometry in swirling jets

    Science.gov (United States)

    Taghavi, R.; Rice, E. J.

    1991-01-01

    Time-averaged and fluctuating quantities are measured in a free turbulent swirling jet. Data from a two-component laser Doppler anemometry (LDA) are compared to the measurements via hot-wire and 5-hole pitot probes. To acquire the proper seeding density near the axis of a swirling jet for LDA measurements proved difficult. This is due to an imbalance of the centrifugal force and radial pressure gradient, which throws the seeding material off the axis. Despite this problem, close agreement between various measurement techniques is obtained.

  14. A compact differential laser Doppler velocimeter using a semiconductor laser

    NARCIS (Netherlands)

    Jentink, H.W.; Beurden, van J.A.J.; Helsdingen, M.A.; Mul, de F.F.M.; Suichies, H.E.; Aarnoudse, J.G.; Greve, J.

    1987-01-01

    A small differential laser Doppler velocimeter which uses a semiconductor laser and a small number of optical components is described. In this device the light from the laser diode is split into coherent beams by means of a diffraction grating. The two first-order beams are crossed in a probe volume

  15. Laser controlling chaotic region of a two-component Bose-Einstein condensate

    Institute of Scientific and Technical Information of China (English)

    Boli Xia; Wenhua Hai

    2005-01-01

    @@ For a weakly and periodically driven two-component Bose-Einstein condensate (BEC) the Melnikov chaotic solution and boundedness conditions are derived from a direct perturbation theory that leads to the chaotic regions in the parameter space.

  16. Mobile fiber-optic laser Doppler anemometer.

    Science.gov (United States)

    Stieglmeier, M; Tropea, C

    1992-07-20

    A laser Doppler anemometer (LDA) has been developed that combines the compactness and low power consumption of laser diodes and avalanche photodiodes with the flexibility and possibility of miniaturization by using fiber-optic probes. The system has been named DFLDA for laser diode fiber LDA and is especially suited for mobile applications, for example, in trains, airplanes, or automobiles. Optimization considerations of fiber-optic probes are put forward and several probe examples are described in detail. Measurement results from three typical applications are given to illustrate the use of the DFLDA. Finally, a number of future configurations of the DFLDA concept are discussed.

  17. Fish embryo multimodal imaging by laser Doppler digital holography

    CERN Document Server

    Verrier, Nicolas; Picart, Pascal; Gross, Michel

    2015-01-01

    A laser Doppler imaging scheme combined to an upright microscope is proposed. Quantitative Doppler imaging in both velocity norm and direction, as well as amplitude contrast of either zebrafish flesh or vasculature is demonstrated.

  18. Numerical modeling of sintering of two-component metal powders with laser beams

    Science.gov (United States)

    Niziev, V. G.; Koldoba, A. V.; Mirzade, F. Kh.; Panchenko, V. Ya.; Poveschenko, Yu. A.; Popov, M. V.

    2011-02-01

    Direct laser sintering of a mixture of two metal powders with significantly different melting points is investigated by numerical simulation. The model is based on self-consistent non-linear continuity equations for volume fractions of components and on energy transfer equations for the powder mixture. It includes the movement of the solid particles due to shrinkage because of the density change of the powder mixture and the liquid flow driven by the capillary and gravity forces. The liquid flow is determined by Darcy's law. The effect of surface settlement of the powder is obtained. The width increasing rate of the melting zone depend both on the parameters of the laser radiation (on the power of the beam) and on the physical parameters of the particle's material, and it increases with the increasing of the penetrability or the increasing of the phase-transition heat. The increasing of the laser power under other factors being equal results in the acceleration of the melting front propagation.

  19. Measurement of depth of burns by laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Droog, E.J.; Droog, E.J.; Steenbergen, Wiendelt; Sjöberg, F.

    2001-01-01

    Laser Doppler perfusion imaging (LDPI), is a further development in laser Doppler flowmetry (LDF). Its advantage is that it enables assessment of microvascular blood flow in a predefined skin area rather than, as for LDF, in one place. In many ways this method seems to be more promising than LDF in

  20. Measurement of depth of burns by laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Droog, E.J.; Steenbergen, W.; Sjöberg, F.

    2001-01-01

    Laser Doppler perfusion imaging (LDPI), is a further development in laser Doppler flowmetry (LDF). Its advantage is that it enables assessment of microvascular blood flow in a predefined skin area rather than, as for LDF, in one place. In many ways this method seems to be more promising than LDF in

  1. Laser Doppler vibrometry: new ENT applications

    Science.gov (United States)

    Stasche, Norbert; Baermann, M.; Kempe, C.; Hoermann, Karl; Foth, Hans-Jochen

    1996-12-01

    Common audiometry often does not really allow a reliable and objective differential diagnosis of hearing disorders such as otosclerosis, adhesive otitis, ossicular interruption or tinnitus, even though several methods might be used complementarily. In recent years, some experimental studies on middle ear mechanics established laser Doppler vibrometry (LDV) as a useful method allowing objective measurement of human tympanic membrane displacement. The present study on LDV investigated the clinical use of this new method under physiological conditions. LDV proved to be a fast, reproducible, non-invasive and very sensitive instrument to characterize ear-drum vibrations in various middle ear dysfunctions, except in tinnitus patients. For future applications, improved optical characteristics of the vibrometer might result in a better differential diagnosis of subjective and objective tinnitus, otoacoustic emissions or Morbus Meniere.

  2. Widefield laser doppler velocimeter: development and theory.

    Energy Technology Data Exchange (ETDEWEB)

    Hansche, Bruce David; Reu, Phillip L.; Massad, Jordan Elias

    2007-03-01

    The widefield laser Doppler velocimeter is a new measurement technique that significantly expands the functionality of a traditional scanning system. This new technique allows full-field velocity measurements without scanning, a drawback of traditional measurement techniques. This is particularly important for tests in which the sample is destroyed or the motion of the sample is non-repetitive. The goal of creating ''velocity movies'' was accomplished during the research, and this report describes the current functionality and operation of the system. The mathematical underpinnings and system setup are thoroughly described. Two prototype experiments are then presented to show the practical use of the current system. Details of the corresponding hardware used to collect the data and the associated software to analyze the data are presented.

  3. Laser Doppler flowmetry in endodontics: a review.

    Science.gov (United States)

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  4. MEMS characterization using Laser Doppler Vibrometry

    Science.gov (United States)

    Lawrence, Eric M.; Speller, Kevin E.; Yu, Duli

    2003-01-01

    The use of Laser Doppler Vibrometry (LDV) technology has been at the forefront of Micro-Electro-Mechanical Systems (MEMS) research since the early 1990"s. By its nature as a sensitive laser optical technique, it is well suited for non-contact dynamic response measurements of microscopic structures. The art of the technology has culminated into the latest micro-scanning vibrometer for automated scan measurement and display of deflection shapes with sub-nanometer resolution. To exemplify the use of this technology, Polytec PI presents characterization measurements in collaboration with Applied MEMS on two of their devices used in commercial applications. LDV characterization measurements are used for validating the design of the Applied MEMS two-axis micro mirror. Scan measurements reveal distinct, isolated rotation modes about x- and y- axes that can be used to promote the mirror motion in either direction. Settling time performance is evaluated from impulse response and optimized using Input Shaping techniques. Scan measurements of a low-noise accelerometer device from Applied MEMS reveals spurious high frequency modes of support spring causing unwanted response effects. Further use of a new time domain animation feature shows ringing response of the accelerometer to step motions.

  5. Universal miniaturized signal evaluation for laser doppler anemometers; Universelle Miniatur-Signalauswertung fuer die Laser Doppler Anemometrie

    Energy Technology Data Exchange (ETDEWEB)

    Wnuck, J. von; Strunck, V.; Dopheide, D.

    1994-01-01

    A laser doppler anemometer (LDA) is a contactless optical sensor for flow rate measurement. Interference of two laser beams generates a measuring volume with interference lines in the point of intersection. A particle moving through the measuring volume with a current scatters light modulated wiith the doppler frequency, which is received by a detector. The frequency of the doppler-modulated light is proportional to the velocity of the particle. The report describes the technical details of an electronic evaluation system for laser doppler signals in the time range using programmable gate arrays by Xilinix. (orig.) [Deutsch] Ein Laser Doppler Anemometer (LDA) ist ein beruehrungsloser optischer Sensor, der Stroemungsgeschwindigkeiten misst. Die Ueberlagerung zweier Laserstrahlen erzeugt im Schnittpunkt ein Messvolumen mit Inferenzstreifen. Ein Teilchen, das sich mit einer Stroemung durch das Messvolumen bewegt, streut mit der Doppelfrequenz des Doppler moduliertes Licht, das von einem Detektor empfangen wird. Die Frequenz des Doppler-modulierten Lichts ist der Geschwindigkeit des Teilchens proportional. Hier wird die technische Realisierung einer Auswerteelektronik fuer Laser Doppler Signale im Zeitbereich mit programmierbaren Gate-Arrays von Xilinx beschrieben. (orig.)

  6. Estimation of amputation level with a laser Doppler flowmeter

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Jørgensen, J P; Vollmer-Larsen, B;

    1989-01-01

    Leg amputation levels were decided in 24 patients suffering from atherosclerosis, using the conventional techniques of segmental blood pressure and radioisotope skin clearance. The skin microcirculation was measured and recorded before operation with a laser doppler flowmeter. A high correlation ...

  7. Muscle activity characterization by laser Doppler Myography

    Science.gov (United States)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  8. Interpreting laser Doppler recordings from free flaps.

    Science.gov (United States)

    Svensson, H; Holmberg, J; Svedman, P

    1993-01-01

    Although the transfer of free flaps is nowadays accomplished with an increasing degree of safety, thrombosis of the microvascular anastomoses is still a problem. In order to avoid delay in re-operating, various methods for objective blood flow monitoring have been tried, among them Laser Doppler Flowmetry (LDF). When one reviews the literature, it is apparent that opinions differ about whether or not LDF is a reliable technique for this purpose. To focus on the need to interpret continuous recordings, this paper reports our findings in six latissimus dorsi free flaps chosen from our series of LDF monitoring procedures. One uneventful flap, no. 1, had an immediate postoperative LDF value of 4.5 perfusion units (PU). LDF values improved during the recovery period and the graphic recording showed fluctuations due to normal physiological variations of the blood flow in the flap. Another uneventful flap, no. 4, showed the same pattern, though at an appreciably lower level, 2 PU, on average. Flap no. 2 had an acceptably high value of 3.5 PU despite suffering a venous thrombosis. However, the LDF recording showed no fluctuations and the value declined gradually. Another flap, no. 3, showed fluctuations and blood flow was normal although the value decreased to 2.5 PU. In flap no. 5, any value between 2 and 3.5 PU could be obtained merely by adjusting the position of the probe in the holder. In no. 6, the LDF value suddenly dropped, accompanied by a decrease in the total amount of backscattered light, indicating venous obstruction which was confirmed at re-operation.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Miniature Laser Doppler Velocimeter for Measuring Wall Shear

    Science.gov (United States)

    Gharib, Morteza; Modarress, Darius; Forouhar, Siamak; Fourguette, Dominique; Taugwalder, Federic; Wilson, Daniel

    2005-01-01

    A miniature optoelectronic instrument has been invented as a nonintrusive means of measuring a velocity gradient proportional to a shear stress in a flow near a wall. The instrument, which can be mounted flush with the wall, is a variant of a basic laser Doppler velocimeter. The laser Doppler probe volume can be located close enough to the wall (as little as 100 micron from the surface) to lie within the viscosity-dominated sublayer of a turbulent boundary layer. The instrument includes a diode laser, the output of which is shaped by a diffractive optical element (DOE) into two beams that have elliptical cross sections with very high aspect ratios.

  10. Design of new seismometer based on laser Doppler effect

    Institute of Scientific and Technical Information of China (English)

    Zhenhui Du(杜振辉); Fuxiang Huang(黄福祥); Chengzhi Jiang(蒋诚志); Zhifei Tao(陶知非); Hua Gao(高华); Lina Lü(吕丽娜)

    2004-01-01

    In order to improve the resolution of seismic acquisition, a new seismic acquisition system based on tangential laser Doppler effect with an optimized differential optical configuration is proposed. The relative movement of the inertia object and the immobile frame is measured by laser Doppler effect, which can avoid the electromagnetic and thermometric interference, and the adoption of frequency-modulated (FM)transmission can improve the ability of anti-jamming. The frequency bandwidth is properly determined by analyzing the frequency of the Doppler signal. The velocity, displacement, acceleration, and frequency to be measured can be real-time acquired by frequency/velocity (F/V) converting the FM Doppler signal.A 100-dB dynamic range and the linear frequency range of 1.0 to 1000 Hz are realized.

  11. Processor operated correlator with applications to laser Doppler signals

    DEFF Research Database (Denmark)

    Bisgaard, C.; Johnsen, B.; Hassager, Ole

    1984-01-01

    A 64-channel correlator is designed with application to the processing of laser Doppler anemometry signals in the range 200 Hz to 250 kHz. The correlator is processor operated to enable the consecutive sampling of 448 correlation functions at a rate up to 500 Hz. Software is described to identify...... a Doppler frequency from each correlation and the system is especially designed for transient flow signals. Doppler frequencies are determined with an accuracy of about 0.1%. Review of Scientific Instruments is copyrighted by The American Institute of Physics....

  12. Laser Doppler perfusion monitoring and imaging of blood microcirculation

    Science.gov (United States)

    Nilsson, Gert E.; Wardell, Karin

    1994-07-01

    Laser Doppler perfusion monitoring is a method of assessing tissue perfusion based on measurements performed using Doppler broadening of monochromatic light scattered in moving blood cells. Ever since laser Doppler perfusion monitors became available about 15 years ago they have been used in numerous applications in both clinical and laboratory settings. The high spatial resolution has in practice manifested itself as one of the main limitations of the method. The reason for this is the difficulty in attaining reproducible values at successive measurement sites because most skin tissue possesses a substantial variation in blood flow even at adjacent measurement sites. In order to overcome this difficulty the laser Doppler perfusion imager was developed. In this camera-like device, the laser beam successively scans the tissue and the Doppler components of the backscattered light are detected by a remote photodiode. After a scanning procedure is complete, a color-coded perfusion map showing the spatial variation of skin blood flow is displayed on a monitor. The operating principle and early applications of this emerging technology are addressed in further detail.

  13. Influence of laser frequency noise on scanning Fabry-Perot interferometer based laser Doppler velocimetry

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2014-01-01

    n this work, we study the performance of a scanning Fabry-Perot interferometer based laser Doppler velocimeter (sFPILDV) and compare two candidate 1.5 um single-frequency laser sources for the system – a fiber laser (FL) and a semiconductor laser (SL). We describe a straightforward calibration pr...

  14. All semiconductor laser Doppler anemometer at 1.55 microm.

    Science.gov (United States)

    Hansen, René Skov; Pedersen, Christian

    2008-10-27

    We report to our best knowledge the first all semiconductor Laser Doppler Anemometer (LIDAR) for wind speed determination. We will present the design and first experimental results on a focusing coherent cw laser Doppler anemometer for measuring atmospheric wind velocities in the 10 meters to 300 meters distance range. Especially, we will demonstrate that both the output power as well as the demanding coherence properties required from the laser source can be accomplished by an all semiconductor laser. Preliminary tests at a distance of 40 meters indicate a typical signal to noise ratio of 9 dB. This result is obtained at a clear day with an up-date rate of 12 Hz.

  15. Holographic laser Doppler imaging of microvascular blood flow

    CERN Document Server

    Magnain, C; Boucneau, T; Simonutti, M; Ferezou, I; Rancillac, A; Vitalis, T; Sahel, J A; Paques, M; Atlan, M

    2014-01-01

    We report on local superficial blood flow monitoring in biological tissue from laser Doppler holographic imaging. In time averaging recording conditions, holography acts as a narrowband bandpass filter, which, combined with a frequency shifted reference beam, permits frequency selective imaging in the radiofrequency range. These Doppler images are acquired with an off axis Mach Zehnder interferometer. Microvascular hemodynamic components mapping is performed in the cerebral cortex of the mouse and the eye fundus of the rat with near-infrared laser light without any exogenous marker. These measures are made from a basic inverse method analysis of local first order optical fluctuation spectra at low radiofrequencies, from 0 Hz to 100 kHz. Local quadratic velocity is derived from Doppler broadenings induced by fluid flows, with elementary diffusing wave spectroscopy formalism in backscattering configuration. We demonstrate quadratic mean velocity assessment in the 0.1 to 10 millimeters per second range in vitro ...

  16. Coherent Doppler Laser Radar: Technology Development and Applications

    Science.gov (United States)

    Kavaya, Michael J.; Arnold, James E. (Technical Monitor)

    2000-01-01

    NASA's Marshall Space Flight Center has been investigating, developing, and applying coherent Doppler laser radar technology for over 30 years. These efforts have included the first wind measurement in 1967, the first airborne flights in 1972, the first airborne wind field mapping in 1981, and the first measurement of hurricane eyewall winds in 1998. A parallel effort at MSFC since 1982 has been the study, modeling and technology development for a space-based global wind measurement system. These endeavors to date have resulted in compact, robust, eyesafe lidars at 2 micron wavelength based on solid-state laser technology; in a factor of 6 volume reduction in near diffraction limited, space-qualifiable telescopes; in sophisticated airborne scanners with full platform motion subtraction; in local oscillator lasers capable of rapid tuning of 25 GHz for removal of relative laser radar to target velocities over a 25 km/s range; in performance prediction theory and simulations that have been validated experimentally; and in extensive field campaign experience. We have also begun efforts to dramatically improve the fundamental photon efficiency of the laser radar, to demonstrate advanced lower mass laser radar telescopes and scanners; to develop laser and laser radar system alignment maintenance technologies; and to greatly improve the electrical efficiency, cooling technique, and robustness of the pulsed laser. This coherent Doppler laser radar technology is suitable for high resolution, high accuracy wind mapping; for aerosol and cloud measurement; for Differential Absorption Lidar (DIAL) measurements of atmospheric and trace gases; for hard target range and velocity measurement; and for hard target vibration spectra measurement. It is also suitable for a number of aircraft operations applications such as clear air turbulence (CAT) detection; dangerous wind shear (microburst) detection; airspeed, angle of attack, and sideslip measurement; and fuel savings through

  17. Anomaly Detection In Additively Manufactured Parts Using Laser Doppler Vibrometery

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Carlos A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-29

    Additively manufactured parts are susceptible to non-uniform structure caused by the unique manufacturing process. This can lead to structural weakness or catastrophic failure. Using laser Doppler vibrometry and frequency response analysis, non-contact detection of anomalies in additively manufactured parts may be possible. Preliminary tests show promise for small scale detection, but more future work is necessary.

  18. New Type of 2-D Laser Doppler Vibrometer

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The fundamentals and method of 2-D laser Doppler vibrometer are introduced.The factors influencing the measuring accuracy are analyzed. Moreover, the circuit for signal processing is designed. The vibrating amplitude and frequency of 2-D vibration in wider range can be measured simultaneously in non-contact means,the measuring results are accurate.

  19. Laser Doppler velocimetry in Microchannels using integrated optical waveguides.

    NARCIS (Netherlands)

    Pandraud, G.; van den Berg, Albert; Semenov, S.N.

    2000-01-01

    The possibility of laser Doppler velocimetry (LDV) in microchannels, where particles are suspended in a liquid, and where oscillating or evanescent guided coherent light wave is present, is examined theoretically. The conditions for the observation of the transverse and longitudinal collective phore

  20. Review of methodological developments in laser Doppler flowmetry

    NARCIS (Netherlands)

    Rajan, Vinayakrishnan; Varghese, Babu; van Leeuwen, Ton; Steenbergen, Wiendelt

    2009-01-01

    Laser Doppler flowmetry is a non-invasive method of measuring microcirculatory blood flow in tissue. In this review the technique is discussed in detail. The theoretical and experimental developments to improve the technique are reviewed. The limitations of the method are elaborated upon, and the re

  1. Estimation of amputation level with a laser Doppler flowmeter

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Jørgensen, J P; Vollmer-Larsen, B

    1989-01-01

    Leg amputation levels were decided in 24 patients suffering from atherosclerosis, using the conventional techniques of segmental blood pressure and radioisotope skin clearance. The skin microcirculation was measured and recorded before operation with a laser doppler flowmeter. A high correlation...... was found between the successful amputation levels and the maximal blood perfusion of the skin measured in this way....

  2. Experiences using laser Doppler vibrometers at Chernobyl Nuclear Power Plant

    Science.gov (United States)

    Yarovoi, Leonid K.; Robur, Lubomir I.; Siegmund, Georg; Tushev, Dmitry

    2000-05-01

    The implementation of laser vibrometers into various branches of industry solves complex technical problems as well as raising the authority of laser vibrometry as unique measurement tool. From this point of view, the nuclear industry is an interesting and attractive application field with specific and rigorous exploitation conditions of measuring systems. The objective of this work was to evaluate all advantages and disadvantages of the laser Doppler vibrometry with respect to nuclear power plant (NPP) equipment examination. The Chernobyl NPP is the ideal place for these purposes. The diagnostic ability on different Chernobyl NPP systems (e.g. third power unit main circulators, bearing shaft of fifth turbo-generator and various pipelines) has been demonstrated using laser Doppler vibrometers. The measurements performed by laser vibrometers were checked by standard Chernobyl NPP vibration measurement tools. The laser Doppler vibrometers (CLV, Polytec GmbH and LDV, Kiev University) have been tested and have shown full functionality in NPP zone at 0.5 sievert/hour radiation levels, high electromagnetic fields (magnetic component up to 5 kA/m) and significant vibrations.

  3. Is there a difference between laser speckle and laser Doppler in depth sensitivity?

    Science.gov (United States)

    Thompson, O. B.; Hirst, E. R.; Andrews, M. K.

    2011-03-01

    Laser speckle and laser Doppler perfusion measurements apply different analyses to the same physical phenomenon and so should produce the same results. However, there is some evidence that laser Doppler can measure perfusion at greater depths than laser speckle. Using phantom measurements and comparison to spatially modulated imaging, we show why this might be the case. Various implementations of imaging laser Doppler and speckle systems have different optical setups, producing different effective distances between the illumination and detector points on the surface of the tissue. Separating the effective source and detector regions in tissue measurements biases the measurements towards deeper tissues, and when the effective source and detector regions coincide, the measurement is biased towards surface tissues. Probe-based or scanning laser Doppler systems with point illumination can separate the source and detector regions to interrogate deeper tissues, while whole-field imaging laser Doppler systems and laser speckle contrast systems have broad illumination covering the measurement areas. The volume of tissue informing a measurement at any point in a whole-field system, and hence the depth sensitivity, is determined by the optical properties of the tissue at the working wavelength.

  4. A Doppler lidar with CO2-laser intracavity detection

    Science.gov (United States)

    Godlevskii, A. P.; Gordov, E. P.; Zhiliba, A. I.; Sharin, P. P.

    A version of a high-sensitive Doppler lidar, based on intracavity coherent laser detection is described. The device consists of a CO2 laser, transmitting-receiving optical system, and signal-processing unit. Laser-intensity stabilization is achieved by decreasing the mechanical disturbance of the laser resonator, and the optical tract is formed by a Cassegrain telescope. A portion of the laser beam reflected back by a Breuster window of the gas discharge tube is focused by a spherical mirror onto a photodetector. Results of laboratory and real-atmosphere experiments are reported, and it is shown that vibrations of a retroreflector with an amplitude of 50 micron are detected at distances up to 500 m.

  5. Scanning laser Doppler vibrometry of the middle ear ossicles.

    Science.gov (United States)

    Ball, G R; Huber, A; Goode, R L

    1997-04-01

    This paper describes measurements of the vibratory modes of the middle ear ossicles made with a scanning laser Doppler vibrometer. Previous studies of the middle ear ossicles with single-point laser Doppler measurements have raised questions regarding the vibrational modes of the ossicular chain. Single-point analysis methods do not have the ability to measure multiple points on the ossicles and, consequently, have limited ability to simultaneously record relative phase information at these points. Using a Polytec Model PSV-100, detailed measurements of the ossicular chain have been completed in the human temporal bone model. This model, when driven with a middle ear transducer, provides detailed three-dimensional data of the vibrational patterns of the middle ear ossicles. Implications for middle ear implantable devices are discussed.

  6. Laser Doppler anemometer studies in unsteady ventricular flows.

    Science.gov (United States)

    Phillips, W M; Furkay, S S; Pierce, W S

    1979-01-01

    The laser Doppler technique was employed to obtain intraventricular velocity distributions on the basis of in vivo confirmation of previous in vitro flow visualization predictions. The quasi-steady assumption required for quantification of flow visualization results is unsatisfactory in regions of high acceleration and fluctuating velocities are unavailable via such techniques. Mean and fluctuating velocity profiles were obtained in a pneumatically driven prosthetic ventricle with the laser Doppler anemometer and stress levels estimated. The preliminary data presented here illustrates that the technique can be applied to such flows. The measurement and data reduction schemes are applicable to a wide range of simulated cardiovascular flows. The particular application to prosthetic ventricle design should minimize the number of in vivo experiments required to develop a satisfactory blood pump and aid in tailoring pump actuation protocols for minimum thromboembolic complications.

  7. Particle-In-Cell simulation of laser irradiated two-component microspheres in 2 and 3 dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Pauw, Viktoria, E-mail: viktoria.pauw@physik.uni-muenchen.de [Ludwig-Maximilians-Universität München, 80539 (Germany); Ostermayr, Tobias M. [Ludwig-Maximilians-Universität München, 80539 (Germany); Max-Planck-Institut für Quantenoptik, 85748 Garching (Germany); Bamberg, Karl-Ulrich [Ludwig-Maximilians-Universität München, 80539 (Germany); Leibniz-Rechenzentrum, 85748 Garching (Germany); Böhl, Patrick; Deutschmann, Fabian; Kiefer, Daniel; Klier, Constantin; Moschüring, Nils; Ruhl, Hartmut [Ludwig-Maximilians-Universität München, 80539 (Germany)

    2016-09-01

    We examine proton acceleration from spherical carbon-hydrogen targets irradiated by a relativistic laser pulse. Particle-In-Cell (PIC) simulations are carried out in 2 and 3 dimensions (2D and 3D) to compare fast proton spectra. We find very different final kinetic energies in 2D and 3D simulations. We show that they are caused by the different Coulomb fields in 2D and 3D. We propose a correction scheme for the proton energies to test this hypothesis. In the case of sub-focus diameter targets comparison of corrected 2D energies with 3D results show good agreement. This demonstrates that caution is required when modeling experiments with simulations of reduced dimensionality. - Highlights: • A laser-irradiated polysterene microsphere is modeled in a 2D3V-PIC simulation. • Different results are obtained for different linear laser polarisation directions. • 3D3V simulations are carried out and compared to the 2D cases. • A model is proposed explaining the different energies by Coulomb field alteration.

  8. Laser Doppler flowmetry in diagnoses of chronic tonsillitis

    Science.gov (United States)

    Mareew, Gleb O.; Mareew, Oleg V.; Maslyakova, Galina N.; Ivliev, Igor I.; Fedosov, Ivan V.; Lychagov, Vladislav V.; Tuchin, Valery V.

    2005-06-01

    Chronic tonsillitis is one of the most common diseases in ENT all over the world. There are two ways of treatment-surgical tonsillectomy and conservative therapeutically treatment. But still doctors have no possibility to make objective decisions for this painful and tonsil-destructive operation. In this article we try to research how the degree of sclerosis in tonsillar tissue affects the blood flow in tonsils, by using laser Doppler flowmetry.

  9. Velocity Measurement Based on Laser Doppler Effect

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yan-Yan; HUO Yu-Jing; HE Shu-Fang; GONG Ke

    2010-01-01

    @@ A novel method for velocity measurement is presented.In this scheme,a parallel-linear-polarization dualfrequency laser is incident on the target and senses the target velocity with both the frequencies,which can increase the maximum measurable velocity significantly.The theoretical analysis and verification experiment of the novel method are presented,which show that high-velocity measurement can be achieved with high precision using this method.

  10. Thermal tests for laser Doppler perfusion measurements in Raynaud's syndrome

    Science.gov (United States)

    Kacprzak, Michal; Skora, A.; Obidzinska, J.; Zbiec, A.; Maniewski, Roman; Staszkiewicz, W.

    2004-07-01

    The laser Doppler method offers a non-invasive, real time technique for monitoring of blood perfusion in microcirculation. In practical measurements the perfusion index is given only in relative values. Thus, accurate and reproducible results can be only obtained when using a well controlled stimulation test. The aim of this study was evaluation of the thermal stimulation test, which is frequently used to investigate microcirculation in patients with Raynaud's syndrome. Three types of thermal tests, in which air or water with temperature in range 5°C - 40°C were used. Ten normal volunteers and fifteen patients with clinical symptoms of the primary Raynaud's syndrome were enrolled in this study. To estimate skin microcirculation changes during the thermal test, the multichannel laser Doppler system and laser Doppler scanner were used. The obtained results were analyzed from the point of view of the efficiency of these methods and the thermal provocative tests in differentiation of normal subjects and patient with Raynaud's syndrome.

  11. Laser Doppler interferometer for vibration of rotating curved surfaces

    Science.gov (United States)

    Wu, Giin-Yuan; Lee, Chih-Kung; Lin, San; Wakabayashi, Takenori; Ono, K.

    1999-10-01

    With the rapid advancement of today's ultra-high performance mechanical or mechatronic system such as magnetic or optical disk drives, improving metrology capabilities to examine the performance characteristics of these system are growing ever more important. The primary tested studied in this paper is an ultra-high precision ball-bearing spindle that possesses non-repeatable runout of less than 100nm. The metrology tool adopted is laser Doppler interferometer system that has Megahertz bandwidth and nanometer resolutions. Experimental data obtained clearly indicates that measuring vertical runout of a spindle motor is a straightforward process. However, a fundamental effect was identified, where the radial runout data was found to drift upward or downward with time, when using the laser Doppler system to measure the radial runout of ultra-high precision rotational systems whose surface profile is not flat. All of the underlying reasons that cause this undesirable effect were proposed and verified. Approaches that can be adopted to circumvent this apparent limitation on adopting the laser Doppler interferometer systems to measure rotational curved surface were implemented to further extend its application horizon. The experimental data realized and the application experience obtained were shown to further advance our measurement capabilities.

  12. Sub-Doppler Laser Cooling using Electromagnetically Induced Transparency

    CERN Document Server

    He, Peiru; Anderson, Dana Z; Rey, Ana Maria; Holland, Murray

    2016-01-01

    We propose a sub-Doppler laser cooling mechanism that takes advantage of the unique spectral features and extreme dispersion generated by the phenomenon of electromagnetically induced transparency (EIT). EIT is a destructive quantum interference phenomenon experienced by atoms with multiple internal quantum states when illuminated by laser fields with appropriate frequencies. By detuning the lasers slightly from the "dark resonance", we observe that, within the transparency window, atoms can be subject to a strong viscous force, while being only slightly heated by the diffusion caused by spontaneous photon scattering. In contrast to other laser cooling schemes, such as polarization gradient cooling or EIT-sideband cooling, no external magnetic field or strong external confining potential is required. Using a semiclassical approximation, we derive analytically quantitative expressions for the steady-state temperature, which is confirmed by full quantum mechanical numerical simulations. We find that the lowest ...

  13. Integrated optoelectronic probe including a vertical cavity surface emitting laser for laser Doppler perfusion monitoring

    NARCIS (Netherlands)

    Serov, Alexander N.; Nieland, Janharm; Oosterbaan, Sjoerd; Mul, de Frits F.M.; Kranenburg, van Herma; Bekman, Herman H.P.Th.; Steenbergen, Wiendelt

    2006-01-01

    An integrated optoelectronic probe with small dimensions, for direct-contact laser Doppler blood flow monitoring has been realized. A vertical cavity surface emitting laser (VCSEL), and a chip with photodetectors and all necessary electronics are integrated in a miniature probe head connected to a l

  14. Integrated Optoelectronic Probe Including a Vertical Cavity Surface Emitting Laser for Laser Doppler Perfusion Monitoring

    NARCIS (Netherlands)

    Serov, A.N.; Nieland, J.; Oosterbaan, S.; Steenbergen, W.; Bekman, H.H.P.T.; Mul, F.F.M. de; Kranenburg, H. van

    2006-01-01

    An integrated optoelectronic probe with small dimensions, for direct-contact laser Doppler blood flow monitoring has been realized. A vertical cavity surface emitting laser (VCSEL), and a chip with photodetectors and all necessary electronics are integrated in a miniature probe head connected to a l

  15. Generalized Laser Doppler Vibrometer noise maps

    Science.gov (United States)

    O'Malley, Patrick; Vignola, Joseph; Judge, John

    2012-06-01

    In a previous work[1], the authors presented preliminary data showing how noise can be mapped as a function of beam focus and standoff distance. This analysis builds on the previous work, but presents a method of mapping laser Dopopler vibrometer (LDV) noise which can be broadly generalized. The apparatus used in the experiments is a Polytec OFV505 with a custom servo-actuated attachment to the focus ring, which is mounted to linear positioning stages to control standoff distance and dither location. A high resolution grid of measurement locations is generated to create a map of signal strength as a function of both standoff distance and "focus error" - a description of the degree to which the beam is defocused, expressed in terms of how the standoff would need to be adjusted in order to move the beam into focus. Using this approach, the particular optics of the LDV system are no longer directly a factor, as determining the relationship between the focus adjustment and standoff distance should be possible with any system. Further noise maps from experiments which dither the horizontal location of the measurement beam show how the signal field can change for nearby measurement locations on a rough surface and highlight the importance of averaging LDV measurements.

  16. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  17. Holographic laser Doppler imaging of pulsatile blood flow

    CERN Document Server

    Bencteux, Jeffrey; Kostas, Thomas; Bayat, Sam; Atlan, Michael

    2015-01-01

    We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real-time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded optical signal was linked to local instantaneous out-of-plane motion of the skin at velocities of a few hundreds of microns per second, and compared to blood pulse monitored by plethysmoraphy during an occlusion-reperfusion experiment.

  18. Laser Doppler anemometer measurements using nonorthogonal velocity components: error estimates.

    Science.gov (United States)

    Orloff, K L; Snyder, P K

    1982-01-15

    Laser Doppler anemometers (LDAs) that are arranged to measure nonorthogonal velocity components (from which orthogonal components are computed through transformation equations) are more susceptible to calibration and sampling errors than are systems with uncoupled channels. In this paper uncertainty methods and estimation theory are used to evaluate, respectively, the systematic and statistical errors that are present when such devices are applied to the measurement of mean velocities in turbulent flows. Statistical errors are estimated for two-channel LDA data that are either correlated or uncorrelated. For uncorrelated data the directional uncertainty of the measured velocity vector is considered for applications where mean streamline patterns are desired.

  19. Fiber-optic laser Doppler turbine tip clearance probe.

    Science.gov (United States)

    Büttner, Lars; Pfister, Thorsten; Czarske, Jürgen

    2006-05-01

    A laser Doppler based method for in situ single blade tip clearance measurements of turbomachines with high precision is presented for what we believe is the first time. The sensor is based on two superposed fanlike interference fringe systems generated by two laser wavelengths from a fiber-coupled, passive, and therefore compact measurement head employing diffractive optics. Tip clearance measurements at a transonic centrifugal compressor performed during operation at 50,000 rpm (833 Hz, 586 m/s tip speed) are reported. At these speeds the measured uncertainty of the tip position was less than 20 microm, a factor of 2 more accurate than that of capacitive probes. The sensor offers great potential for in situ and online high-precision tip clearance measurements of metallic and nonmetallic turbine blades.

  20. All semiconductor laser Doppler anemometer at 1.55 μm

    DEFF Research Database (Denmark)

    Hansen, Rene Skov; Pedersen, Christian

    2008-01-01

    We report to our best knowledge the first all semiconductor Laser Doppler Anemometer (LIDAR) for wind speed determination. We will present the design and first experimental results on a focusing coherent cw laser Doppler anemometer for measuring atmospheric wind velocities in the 10 meters to 300...

  1. Effect of intracapsular hyperpressure on femoral head blood flow. Laser Doppler flowmetry in dogs.

    Science.gov (United States)

    Vegter, J; Klopper, P J

    1991-08-01

    Intracapsular hyperpressure in the hip joint of dogs affected femoral head blood flow, especially in the juvenile animals. Graphic recording of the laser Doppler signal curve using rapid sampling time demonstrated venous hip joint tamponade in both juvenile and adult dogs. Laser Doppler flowmetry seems to be a sensitive and reproducible method to demonstrate femoral-head blood-flow changes.

  2. GLASS-FIBER SELF-MIXING DIODE-LASER DOPPLER-VELOCIMETER

    NARCIS (Netherlands)

    KOELINK, MH; SLOT, M; DEMUL, FFM; GREVE, J; GRAAFF, R; DASSEL, ACM; AARNOUDSE, JG

    1992-01-01

    A novel diode-laser Doppler velocimeter based on self-mixing feedback of Doppler-shifted light in the laser through a single glass fibre is described. The instrument can be applied, for example, to the invasive measurement of blood velocities in blood vessels, and of other industrial fluids and soli

  3. Sub-Doppler laser cooling using electromagnetically induced transparency

    Science.gov (United States)

    He, Peiru; Tengdin, Phoebe M.; Anderson, Dana Z.; Rey, Ana Maria; Holland, Murray

    2017-05-01

    We propose a sub-Doppler laser-cooling mechanism that takes advantage of the unique spectral features and extreme dispersion generated by the phenomenon of electromagnetically induced transparency (EIT). EIT is a destructive quantum interference phenomenon experienced by atoms with multiple internal quantum states when illuminated by laser fields with appropriate frequencies. By detuning the lasers slightly from the "dark resonance," we observe that, within the transparency window, atoms can be subject to a strong viscous force, while being only slightly heated by the diffusion caused by spontaneous photon scattering. In contrast to other laser-cooling schemes, such as polarization gradient cooling or EIT-sideband cooling, no external magnetic field or strong external confining potential is required. Using a semiclassical approximation, we derive analytically quantitative expressions for the steady-state temperature, which is confirmed by full quantum mechanical numerical simulations. We find that the lowest achievable temperatures approach the single-photon recoil energy. In addition to dissipative forces, the atoms are subject to a stationary conservative potential, leading to the possibility of spatial confinement. We find that under typical experimental parameters, this effect is weak and stable trapping is not possible.

  4. UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry in the diagnostics of alopecia

    Science.gov (United States)

    Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.

    2016-04-01

    Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.

  5. All-Fiber Configuration Laser Self-Mixing Doppler Velocimeter Based on Distributed Feedback Fiber Laser.

    Science.gov (United States)

    Wu, Shuang; Wang, Dehui; Xiang, Rong; Zhou, Junfeng; Ma, Yangcheng; Gui, Huaqiao; Liu, Jianguo; Wang, Huanqin; Lu, Liang; Yu, Benli

    2016-07-27

    In this paper, a novel velocimeter based on laser self-mixing Doppler technology has been developed for speed measurement. The laser employed in our experiment is a distributed feedback (DFB) fiber laser, which is an all-fiber structure using only one Fiber Bragg Grating to realize optical feedback and wavelength selection. Self-mixing interference for optical velocity sensing is experimentally investigated in this novel system, and the experimental results show that the Doppler frequency is linearly proportional to the velocity of a moving target, which agrees with the theoretical analysis commendably. In our experimental system, the velocity measurement can be achieved in the range of 3.58 mm/s-2216 mm/s with a relative error under one percent, demonstrating that our novel all-fiber configuration velocimeter can implement wide-range velocity measurements with high accuracy.

  6. Burst digital correlator as laser-Doppler velocimetry signal processor.

    Science.gov (United States)

    Ikeda, Y; Nakajima, T

    1996-06-20

    A burst digital correlator (BDC) has been developed to obtain flow-velocity information at high data rates from wideband laser-Doppler signals of low signal-to-noise ratio (below 0 dB). Results with artificial signals show that, over a signal bandwidth of 5-120 MHz, the BDC has a measurement accuracy of less than 0.4% at a maximum data rate (number of measurements per second) of 208 kHz when 64 signal samples are correlated. The accuracy is better than 0.05% with a sample size of 512. The performance of the BDC was also evaluated in practical measurements of near-wall and strongly oscillatory recirculating flows.

  7. Laser Doppler flowmetry to measure changes in cerebral blood flow.

    Science.gov (United States)

    Sutherland, Brad A; Rabie, Tamer; Buchan, Alastair M

    2014-01-01

    Laser Doppler flowmetry (LDF) is a method by which relative cerebral blood flow (CBF) of the cortex can be measured. Although the method is easy to employ, LDF only measures relative CBF, while absolute CBF cannot be quantified. LDF is useful for investigating CBF changes in a number of different applications including neurovascular and stroke research. This chapter will prepare the reader for rodent experiments using LDF with two preparations. The closed skull preparation can be used to monitor CBF with an intact skull, but in adult rats, thinning of the skull is required to obtain an accurate cortical CBF signal. The open skull preparation requires a craniotomy to expose the surface of the brain and the LDF probe is held close to the surface to measure cerebral perfusion.

  8. Short-time Fourier transform laser Doppler holography

    CERN Document Server

    Atlan, Michael

    2012-01-01

    We report a demonstration of laser Doppler holography at a sustained acquisition rate of 250 Hz on a 1 Megapixel complementary metal-oxide-semiconductor (CMOS) sensor array and image display at 10 Hz frame rate. The holograms are optically acquired in off-axis configuration, with a frequency-shifted reference beam. Wide-field imaging of optical fluctuations in a 250 Hz frequency band is achieved by turning time-domain samplings to the dual domain via short-time temporal Fourier transformation. The measurement band can be positioned freely within the low radio-frequency spectrum by tuning the frequency of the reference beam in real-time. Video-rate image rendering is achieved by streamline image processing with commodity computer graphics hardware. This experimental scheme is validated by a non-contact vibrometry experiment.

  9. Measurements of enlarged blood pump models using Laser Doppler Anemometer.

    Science.gov (United States)

    Chua, L P; Yu, S C; Leo, H L

    2000-01-01

    In an earlier study (Chua et al., 1998, 1999a), a 5:1 enlarged model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump (Akamatsu et al., 1995) with five different impeller blade profiles was designed and constructed. Their respective flow characteristics with respect to (1) the three different blade profile designs: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed were investigated. Among the five impeller designs, the results obtained suggested that impellers A and C designs should be adopted if higher head is required. Impellers A and C therefore were selected for the flow in between their blades to be measured using Laser Doppler Anemometer (LDA), so as to have a better understanding of the flow physics with respect to the design parameters.

  10. Dead time effects in laser Doppler anemometry measurements

    DEFF Research Database (Denmark)

    Velte, Clara Marika; Buchhave, Preben; George, William K.

    2014-01-01

    We present velocity power spectra computed by the so-called direct method from burst-type laser Doppler anemometer (LDA) data, both measured in a turbulent round jet and generated in a computer. Using today’s powerful computers, we have been able to study more properties of the computed spectra...... frequency range, starting around the cutoff frequency due to the finite size of the MV. Using computer-generated data mimicking the LDA data, these effects have previously been shown to appear due to the effect of dead time, i.e., the finite time during which the system is not able to acquire new...... measurements. These dead times can be traced back to the fact that the burst-mode LDA cannot measure more than one signal burst at a time. Since the dead time is approximately equal to the residence time for a particle traversing a measurement volume, we are dealing with widely varying dead times, which...

  11. Self-mixing dual-frequency laser Doppler velocimeter.

    Science.gov (United States)

    Cheng, Chih-Hao; Lin, Lyu-Chih; Lin, Fan-Yi

    2014-02-10

    A self-mixing (SM) dual-frequency (DF) laser Doppler velocimeter (LDV) (SM DF-LDV) is proposed and studied, which integrates the advantages of both the SM-LDV and the DF-LDV. An optically injected semiconductor laser operated in a dual-frequency period-one (P1) dynamical state is used as the light source. By probing the target with the light-carried microwave generated from the beat of the two optical frequency components, the spectral broadening in the Doppler signal due to the speckle noise can be significantly reduced. Together with an SM configuration, the SM DF-LDV has the advantages of direction discriminability, self-alignment, high sensitivity, and compact setup. In this study, speckle noise reduction and direction discriminability with an SM DF-LDV are demonstrated. The signal-to-noise ratios (SNRs) at different feedback powers are investigated. Benefiting from the high sensitivity of the SM configuration, an SNR of 23 dB is achieved without employing an avalanched photodetector or photomultiplier tube. The velocity resolution and the SNR under different speckle noise conditions are studied. Average velocity resolution of 0.42 mm/s and SNR of 22.1 dB are achieved when a piece of paper is rotating at a transverse velocity of 5 m/s. Compared with a conventional single-frequency LDV (SF-LDV), the SM DF-LDV shows improvements of 20-fold in the velocity resolution and 8 dB in the SNR.

  12. Laser frequency stabilization using a dispersive line shape induced by Doppler Effect.

    Science.gov (United States)

    Wang, Qing; Qi, Xianghui; Liu, Shuyong; Yu, Jiachen; Chen, Xuzong

    2015-02-01

    We report a simple and robust Doppler-free spectroscopic technique to stabilize a laser frequency to the atomic transition. By employing Doppler Effect on the atomic beam, we obtained a very stable dispersive signal with a high signal-to-noise ratio and no Doppler-background, which served as an error signal to electronically stabilize a laser frequency without modulation. For validating the performance of this technique, we locked a DFB laser to the (133)Cs D2 line and observed an efficient suppression of the frequency noise and a long-term reduction of the frequency drifts in a laboratory environment.

  13. Laser Doppler flowmetry evaluation of gingival recovery response after laser treatment

    Science.gov (United States)

    Todea, Carmen; Cânjǎu, Silvana; Dodenciu, Dorin; Miron, Mariana I.; Tudor, Anca; Bǎlǎbuc, Cosmin

    2013-06-01

    This study was performed in order to evaluate in vivo the applicability of Laser Doppler Flowmetry (LDF) in recording the gingival blood flow and to assess the changes of gingival blood flow following gingival reshaping performed with Er:YAG and 980 nm diode lasers. The LDF evaluation was performed on 20 anterior teeth, which underwent reshaping of gingiva, corresponding to 5 female patients (4 anterior teeth/patient), aged between 20 and 35. One part of the mouth was treated with Er:YAG laser (LP, VLP modes, 140 - 250 mJ, 10 - 20 Hz, using cylindrical sapphire tips) and other part with 980 nm diode laser (CW, 4 W, contact mode and saline solution cooling). The gingival blood flow was monitored using a MoorLab laser Doppler equipment (Moor Instruments Ltd., Axminster, UK) with a straight optical probe, MP3b, 10 mm. The data were processed using statistical analysis software SPSS v16.0.1. The investigation showed an evident decrease in perfusion for both areas in comparison with the baseline values 24 hours after treatment. The microvascular blood flow increased significantly after 7 days in both areas but mostly in diode area (p<0.001). After 14 days for the Er:YAG area the blood perfusion returned to the initial value. The results in diode area remained at a high level after 14 days. Both lasers proved efficiency in the surgical treatment of gingival tissue. Moreover, Laser Doppler Flowmetry is adequate for recording changes in gingival blood flow following periodontal surgery.

  14. Sound Power Estimation by Laser Doppler Vibration Measurement Techniques

    Directory of Open Access Journals (Sweden)

    G.M. Revel

    1998-01-01

    Full Text Available The aim of this paper is to propose simple and quick methods for the determination of the sound power emitted by a vibrating surface, by using non-contact vibration measurement techniques. In order to calculate the acoustic power by vibration data processing, two different approaches are presented. The first is based on the method proposed in the Standard ISO/TR 7849, while the second is based on the superposition theorem. A laser-Doppler scanning vibrometer has been employed for vibration measurements. Laser techniques open up new possibilities in this field because of their high spatial resolution and their non-intrusivity. The technique has been applied here to estimate the acoustic power emitted by a loudspeaker diaphragm. Results have been compared with those from a commercial Boundary Element Method (BEM software and experimentally validated by acoustic intensity measurements. Predicted and experimental results seem to be in agreement (differences lower than 1 dB thus showing that the proposed techniques can be employed as rapid solutions for many practical and industrial applications. Uncertainty sources are addressed and their effect is discussed.

  15. Photonic Doppler velocimetry of laser-ablated ultrathin metals.

    Science.gov (United States)

    Valenzuela, A R; Rodriguez, G; Clarke, S A; Thomas, K A

    2007-01-01

    Obtaining velocity information from the interaction of a laser pulse on a metal layer provides insight into the rapid dynamics of material removal and plasma plume physics during ablation. A traditional approach involves using a velocity interferometer system for any reflector (VISAR) on a reflective metal surface. However, when the target is a thin metal layer, the cohesion of the surface is quickly lost resulting in a large spread of particle velocities that cannot be easily resolved by VISAR. This is due to material ejection"confusing" the VISAR measurement surface, effectively washing out the spatial fringe visibility in the VISAR interferometer. A new heterodyne-based optical velocimeter method is the photonic Doppler velocimeter (PDV). Because PDV tracks motion in a frequency encoded temporal electro-optical signal, velocity information is preserved and allows for multiple velocity components to be recorded simultaneously. The challenge lies in extracting PDV velocity information at short (nanosecond) laser ablation time scales with rapidly varying heterodyne beats by using electronic, optical, and analytical techniques to recover the velocity information from a fleeting signal. Here we show how we have been able to obtain velocity information on the nanosecond time scale and are able to compare it to hydrodynamic simulations. Also, we examine refinements to our PDV system by increasing the bandwidth, utilizing different probes, and sampling different analysis techniques.

  16. Fiber-optic Doppler velocimeter based on a dual-polarization fiber grating laser

    Science.gov (United States)

    Kuang, Zeyuang; Cheng, Linghao; Liang, Yizhi; Liang, Hao; Guan, Bai-Ou

    2015-07-01

    A fiber-optic Doppler velocimeter based on a dual-polarization fiber grating laser is demonstrated. The fiber grating laser produces two orthogonally polarized laser outputs with their frequency difference proportional to the intra-cavity birefringence. When the laser outputs are reflected from a moving targets, the laser frequencies will be shifted due to the Doppler effect. It shows that the frequency difference between the beat note of the laser outputs and the beat note of the reflected lasers is proportional to the velocity. The proposed fiber-optic Doppler velocimeter shows a high sensitivity of 0.64 MHz/m/s and is capable of measurement of wide range of velocity.

  17. Seismic imaging in laboratory trough laser Doppler vibrometry

    Science.gov (United States)

    Brito, Daniel; Poydenot, Valier; Garambois, Stéphane; Diaz, Julien; Bordes, Clarisse; Rolando, Jean-Paul

    2016-04-01

    Mimic near-surface seismic field measurements at a small scale, in the laboratory, under a well-controlled environment, may lead to a better understanding of wave propagation in complex media such as in geological materials. Laboratory experiments can help in particular to constrain and refine theoretical and numerical modelling of physical phenomena occurring during seismic propagation, in order to make a better use of the complete set of measurements recorded in the field. We have developed a laser Doppler vibrometer (laser interferometry) platform designed to measure non-contact seismic displacements (or velocities) of a surface. This technology enables to measure displacements as small as a tenth of a nanometer on a wide range of frequencies, from a few tenths to a few megahertz. Our experimental set-up is particularly suited to provide high-density spatial and temporal records of displacements on the edge of any vibrating material. We will show in particular a study of MHz wave propagation (excited by piezoelectric transducers) in cylindrical cores of typical diameter size around 10 cm. The laser vibrometer measurements will be first validated in homogeneous materials cylinders by comparing the measurements to a direct numerical simulation. Special attention will be given to the comparison of experimental versus numerical amplitudes of displacements. In a second step, we will conduct the same type of study through heterogeneous carbonate cores, possibly fractured. Tomographic images of velocity in 2D slices of the carbonate core will be derived based upon on the time of first arrival. Preliminary attempts of tomographic attenuation maps will also be presented based on the amplitudes of first arrivals. Experimental records will be confronted to direct numerical simulations and tomographic images will be compared to x-ray scanner imaging of the cylindrical cores.

  18. Research on Doppler frequency in incoherent FM/CW laser detection

    Science.gov (United States)

    Liu, Kai; Cui, Zhanzhong

    2010-10-01

    The principle of transmitted and received laser in incoherent FM/CW laser detection is different from the one in coherent FM/CW laser detection. The methods for distance solution in both detections are similar. Incoherent FM/CW laser detection uses subcarrier to modulate the intensity of laser, and the photodetector detects the intensity of received signal. The amplified photocurrent is mixed with local oscillator signal, and the intermediate frequency (IF) signal contains the information of distance from sensor to target. The Doppler frequency for this detection is related with the relative radial velocity between sensor and target. The optical frequency is directly modulated with electro-optic device in coherent FM/CW laser detection and the received laser signal is photomixed with transmitted laser signal. The Doppler frequency in the detection relates to the optical frequency. In distance-measuring lidar, the Doppler frequency affects the solution. The Doppler frequency in incoherent FM/CW laser detection is unrelated with optical frequency, and it is much less than the one in coherent FM/CW laser detection, correspondingly. The error in incoherent FM/CW laser detection is smaller. As a result, the incoherent FM/CW laser detection is more suitable for the use of distance-measuring lidar.

  19. Doppler wind lidar using a MOPA semiconductor laser at stable single-frequency operation

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2009-01-01

    A compact master-oscillator power-amplifier semiconductor laser (MOPA-SL) is a good candidate for a coherent light source (operating at 1550 nm) in a Doppler wind Lidar. The MOPA-SL requires two injection currents: Idfb for the distributed-feedback (DFB) laser section (master oscillator) and Iamp...... to the laser. This was done by observing the spectral characteristic of the laser using an optical spectrum at different drive current combinations. When using the laser for a Doppler wind Lidar application, a combination of (Idfb, Iamp) which is close to the center of an identified stable single......-frequency regime is used. The current settings for the laser result in a highly stable Lidar as shown by a 5-day long continuous measurement of the Doppler shift produced by a constantly rotating diffusely reflecting target....

  20. Laser and acoustic Doppler techniques for the measurement of fluid velocities

    Science.gov (United States)

    Cliff, W. C.

    1975-01-01

    An overview of current laser and acoustic Doppler techniques is presented. Results obtained by Doppler anemometry and conventional sensors are compared. Comparisons include simultaneous velocity measurements by hot wire and a three-dimensional laser anemometer made in a gaseous pipe flow as well as direct comparisons of atmospheric velocities measured with propeller and cup anemometry. Scanning techniques are also discussed. Conclusions and recommendations for future work are presented.

  1. A comparison of a coaxial focused laser Doppler system in atmospheric measurements

    Science.gov (United States)

    Karaki, S.

    1973-01-01

    Measurements of atmospheric velocities and turbulence with the laser Doppler system were obtained, and the results compared with cup anemometer and hot-wire measurements in the same wind field. The laser Doppler velocimeter (LDV) is described along with the test procedures. It was found that mean values determined from the LDV data are within 5% of other anemometer data for long time periods, and the LDV measures higher velocities.

  2. Arterial compliance measurement using a noninvasive laser Doppler measurement system

    Science.gov (United States)

    Hast, Jukka T.; Myllylae, Risto A.; Sorvoja, Hannu; Nissilae, Seppo M.

    2000-11-01

    The aim of this study was to study the elasticity of the arterial wall using a non-invasive laser Doppler measurement system. The elasticity of the arterial wall is described by its compliance factor, which can be determined when both blood pressure and the radial velocity of the arterial wall are known. To measure radical velocity we used a self- mixing interferometer. The compliance factors were measured from six healthy volunteers, whose ages were varied from 21 to 32. Although a single volunteer's compliance factor is presented as an example, this paper treated the volunteers as a group. First, the elastic modulus, which is inversely proportional to the compliance factor, was determined. Then, an exponential curve was fitted into the measured data and a characteristic equation for the elastic modulus of the arterial wall was determined. The elastic modulus was calculated at different pressures and the results were compared to the static incremental modulus of a dog's femoral artery. The results indicate that there is a correlation between human elastic and canine static incremental modulus for blood pressures varying from 60 to 110 mmHg.

  3. High-power gas-discharge excimer ArF, KrCl, KrF and XeCl lasers utilising two-component gas mixtures without a buffer gas

    Energy Technology Data Exchange (ETDEWEB)

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    Results of an experimental study of the influence of a gas mixture (laser active medium) composition on an output energy and total efficiency of gas-discharge excimer lasers on ArF* (193 nm), KrCl* (222 nm), KrF* (248 nm) and XeCl* (308 nm) molecules operating without a buffer gas are presented. The optimal ratios of gas components (from the viewpoint of a maximum output energy) of an active medium are found, which provide an efficient operation of laser sources. It is experimentally confirmed that for gas-discharge excimer lasers on halogenides of inert gases the presence of a buffer gas in an active medium is not a necessary condition for efficient operation. For the first time, in two-component gas mixtures of repetitively pulsed gas-discharge excimer lasers on electron transitions of excimer molecules ArF*, KrCl*, KrF* and XeCl*, the pulsed energy of laser radiation obtained under pumping by a transverse volume electric discharge in a low-pressure gas mixture without a buffer gas reached up to 170 mJ and a high pulsed output power (of up to 24 MW) was obtained at a FWHM duration of the KrF-laser pulse of 7 ns. The maximal total efficiency obtained in the experiment with two-component gas mixtures of KrF and XeCl lasers was 0.8%. (lasers)

  4. Monitoring perfusion changes in laser-treated tumors using laser doppler flowmetry

    Science.gov (United States)

    Deans, Abby; Hess, Linda; Koss, Michael; Liu, Hong; Chen, Wei R.

    2006-02-01

    Laser Doppler perfusion monitors are effect tools in understanding blood flow in many different types of biological studies. Because the low-intensity lasers used in Doppler perfusion measurements must interact with moving blood cells, the depth of probe-able tissue is limited to the volume of tissue within the hemisphere of radius ~1mm from the probe tip. In addition, heterogeneities in surface perfusion make precise probe placement very important if one is comparing successive measurements. Consequently, useful tissue perfusion measurements have been difficult to obtain, especially in deep tissues. In this study, a new method was developed for monitoring deep-tissue blood perfusion directionally with the Laserflo laser Doppler perfusion probe. The probe was inserted just under the skin superficially to a rat prostatic tumor through the shaft of a 16-gauge needle, which was modified to allow the probe to be exposed without extending beyond the beveled needle tip. Perfusion measurements of the tumor surface or the skin were made by rotating the bevel to face either inside or outside. Using this technique, tumor tissue can be differentiated from either skin or muscle. To study the responses of tumor to light stimulation, an 805nm biomedical treatment laser was used to irradiate the tumor. The perfusion of the tumor surface was shown to decrease slightly with short treatment laser applications (1W for 30 seconds or 1 minute). After a longer treatment session (5 minutes), the perfusion of the tumor tissue increased significantly. However, with an even longer (10 minutes) treatment, the perfusion of the tumor surface was shown to decrease once again. This trend indicates that before laser heating becomes significant, the perfusion decreases for as yet poorly understood reasons. When laser heating becomes significant, after the five-minute session, the perfusion increases dramatically, corresponding to the expected dilation of blood vessels during tissue heating. After

  5. The two-component theory for accommodation after laser treatment of presbyopia%激光老视术后调节的双因素理论

    Institute of Scientific and Technical Information of China (English)

    JT Lin

    2004-01-01

    Objective:To analyze the clinical results of the laser correction of presbyopia and the accommodation mechanisms based on the elasticity alteration hypothesis and the anterior-shift and lens-relaxation model.Methods:Using light propagation in an eye model,we derive the total refractive power changes as the function of lens-power,corneal-power,anterior chamber depth,globe axial length and the refractive indices of the lens,cornea and humors. Experimental data of lens stretching and accommodation were used to derive some semi-empirical equations for various eye parameters related to total power change. The accommodation amplitude after a laser treatment is described by a two-component Lin dynamic mode given by the anterior shift and lens relaxation. We also propose the Lin-Kadambi hypothesis for the elasticity increasing of sclera-ciliary muscle complex for efficient accommodation and minimum regression.Results:The accommodation amplitude(AA),which is about(73% to 76%) of the lens power change,has a non-linear response to the ciliary body contraction and to the lens thickness changes. We propose that the typical accommodation of 2.0 D after a laser procedure may be achieved by lens relaxation(LR) with radius change or by anterior shift(AS) or by combining LR and AS,where AS is the dominate contribution for aging lens with rigid lens capsule.Conclusion:Clinical results of laser presbyopia reversal(LAPR) may be analyzed by light propagation calculations and the accommodation mechanisms based on the elasticity alteration hypothesis and the anterior-shift and lens-relaxation dynamic model.%目的:对于"激光老视治疗"的临床结果及基于弹性改变假说及晶状体前移及晶状体松弛模式的眼调节机制进行分析.方法:根据光在模型眼中的传导原理,导出了总屈光力因晶状体与角膜屈光力、前房深度、眼轴长度及折射率而改变的函数.使用晶状体伸张及调节实验值导出与总屈光力变化相关的眼

  6. High-power gas-discharge excimer ArF, KrCl, KrF and XeCl lasers utilising two-component gas mixtures without a buffer gas

    Science.gov (United States)

    Razhev, A. M.; Kargapol'tsev, E. S.; Churkin, D. S.

    2016-03-01

    Results of an experimental study of the influence of a gas mixture (laser active medium) composition on an output energy and total efficiency of gas-discharge excimer lasers on ArF* (193 nm), KrCl* (222 nm), KrF* (248 nm) and XeCl* (308 nm) molecules operating without a buffer gas are presented. The optimal ratios of gas components (from the viewpoint of a maximum output energy) of an active medium are found, which provide an efficient operation of laser sources. It is experimentally confirmed that for gas-discharge excimer lasers on halogenides of inert gases the presence of a buffer gas in an active medium is not a necessary condition for efficient operation. For the first time, in two-component gas mixtures of repetitively pulsed gas-discharge excimer lasers on electron transitions of excimer molecules ArF*, KrCl*, KrF* and XeCl*, the pulsed energy of laser radiation obtained under pumping by a transverse volume electric discharge in a low-pressure gas mixture without a buffer gas reached up to 170 mJ and a high pulsed output power (of up to 24 MW) was obtained at a FWHM duration of the KrF-laser pulse of 7 ns. The maximal total efficiency obtained in the experiment with two-component gas mixtures of KrF and XeCl lasers was 0.8%.

  7. Laser Doppler velocimetry measurement of turbulent bubbly channel flow

    Energy Technology Data Exchange (ETDEWEB)

    So, S.; Takagi, S.; Matsumoto, Y. [Department of Mechanical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 (Japan); Morikita, H. [Morikita Shuppan Co. Ltd, 1-4-11,Fujimi Chiyoda-ku, Tokyo 102-0071 (Japan)

    2002-07-01

    Measurements of the turbulence properties of gas-liquid bubbly flows with mono-dispersed 1-mm-diameter bubbles are reported for upward flow in a rectangular channel. Bubble size and liquid-phase velocity were measured using image-processing and laser Doppler velocimetry (LDV), respectively. A description is given of the special arrangements for two-dimensional LDV needed to obtain reliable bubbly flow data, in particular the configuration of the optical system, the distinction of signals from the bubbles and liquid phase. To create the mono-dispersed bubbles, a small amount of surfactant (3-pentanol of 20 ppm) was added to the flow. Whilst this caused a drastic change in bubble size distribution and flow field, it did not affect the turbulence properties of the single-phase flow. In this study, experiments with three different bulk Reynolds numbers (1,350, 4,100, 8,200) were conducted with void fractions less than 1.2%. In all three cases, there was a very high accumulation of bubbles near the wall with bubble slip at the wall. The mean velocity profile of the liquid phase was steeper near the wall owing to the driving force of buoyant bubbles, and the streamwise turbulent intensity in the vicinity of the wall was enhanced. Furthermore the mean velocity profiles of the liquid phase were flattened in the wide region around the channel center. This region was lifted up by the bubble sheet near the wall, giving it a plug-like flow structure. In addition, the turbulent fluctuation and Reynolds stress in the liquid phase are very much suppressed in this region. This strong preferential accumulation near the wall produces the dramatic change of the whole flow structure. (orig.)

  8. Laser Doppler velocimetry measurement of turbulent bubbly channel flow

    Science.gov (United States)

    So, S.; Morikita, H.; Takagi, S.; Matsumoto, Y.

    2002-05-01

    Measurements of the turbulence properties of gas-liquid bubbly flows with mono-dispersed 1-mm-diameter bubbles are reported for upward flow in a rectangular channel. Bubble size and liquid-phase velocity were measured using image-processing and laser Doppler velocimetry (LDV), respectively. A description is given of the special arrangements for two-dimensional LDV needed to obtain reliable bubbly flow data, in particular the configuration of the optical system, the distinction of signals from the bubbles and liquid phase. To create the mono-dispersed bubbles, a small amount of surfactant (3-pentanol of 20 ppm) was added to the flow. Whilst this caused a drastic change in bubble size distribution and flow field, it did not affect the turbulence properties of the single-phase flow. In this study, experiments with three different bulk Reynolds numbers (1,350, 4,100, 8,200) were conducted with void fractions less than 1.2%. In all three cases, there was a very high accumulation of bubbles near the wall with bubble slip at the wall. The mean velocity profile of the liquid phase was steeper near the wall owing to the driving force of buoyant bubbles, and the streamwise turbulent intensity in the vicinity of the wall was enhanced. Furthermore the mean velocity profiles of the liquid phase were flattened in the wide region around the channel center. This region was lifted up by the bubble sheet near the wall, giving it a plug-like flow structure. In addition, the turbulent fluctuation and Reynolds stress in the liquid phase are very much suppressed in this region. This strong preferential accumulation near the wall produces the dramatic change of the whole flow structure.

  9. LASER-DOPPLER VELOCIMETRY AND MONTE-CARLO SIMULATIONS ON MODELS FOR BLOOD PERFUSION IN TISSUE

    NARCIS (Netherlands)

    DEMUL, FFM; KOELINK, MH; KOK, ML; HARMSMA, PJ; GREVE, J; GRAAFF, R; AARNOUDSE, JG

    1995-01-01

    Laser Doppler flow measurements and Monte Carlo simulations on small blood perfusion flow models at 780 nm are presented and compared. The dimensions of the optical sample volume are investigated as functions of the distance of the laser to the detector and as functions of the angle of penetration o

  10. Low-noise III-V metasurface based semiconductor vortex laser and rotational Doppler velocimetry

    Science.gov (United States)

    Seghilani, Mohamed; Chomet, Baptiste; Myara, Mikhael; Sellahi, Mohamed; Legratiet, Luc; Beaudoin, Gregoire; Sagnes, Isabelle; Lalanne, Philippe; Garnache, Arnaud

    2017-03-01

    We demonstrate a surface-emitting laser, based on III-V semiconductor technology with an integrated metasurface, generating vortex-like coherent state in the Laguerre-Gauss basis.24 We use a first order phase perturbation to introduce a weak orbital anisotropy, based on a dielectric metasurface and non-linear laser dynamics, allowing selecting vortex handedness. Moreover, similarly to linear Doppler Shift, light carrying orbital angular momentum L, scattered by a rotating object at angular velocity, experiences a rotational Doppler shift L. We show that this fundamental light matter interaction can be detected exploiting self-mixing in a vortex laser under Doppler-shifted optical feedback, with quantum noise-limited light detection.25 This will allow us to combine a velocity sensor with optical tweezers for micro-manipulation applications, with high performances, simplicity and compactness. Such high performance laser opens the path to widespread new photonic applications.

  11. LASER DOPPLER-VELOCIMETER BASED ON THE SELF-MIXING EFFECT IN A FIBER-COUPLED SEMICONDUCTOR-LASER - THEORY

    NARCIS (Netherlands)

    KOELINK, MH; SLOT, M; DEMUL, FFM; GREVE, J; GRAAFF, R; DASSEL, ACM; AARNOUDSE, JG

    1992-01-01

    A laser Doppler velocimeter that consists of a semiconductor laser coupled to a fiber and that uses the self-mixing effect is presented. The velocimeter can be used for solids and fluids. A theoretical model is developed to describe the self-mixing signals as a function of the amount of feedback int

  12. Research on laser Doppler velocimeter for vehicle self-contained inertial navigation system

    Science.gov (United States)

    Jian, Zhou; Xingwu, Long

    2010-04-01

    An idea of using laser Doppler velocimeter (LDV) to measure the velocity for the vehicle inertial navigation system was put forward. The principle of measuring its own velocity with laser Doppler technique was elaborated and reference-beam LDV was designed. Then Doppler signal was processed by tracking filter, frequency spectrum refinement and frequency spectrum correction algorithm. The result of theory and experiment showed that the reference-beam LDV solved the problem that dual-beam LDV cannot be used for measuring when the system was out of focus. Doppler signal was tracked so that signal-to-noise ratio was improved, and the accuracy of the system was enhanced by the technology of frequency spectrum refinement and correction. The measurement mean error was less than 1.5% in velocity range of 0-30 m/s.

  13. Comparison of laser Doppler and laser speckle contrast imaging using a concurrent processing system

    Science.gov (United States)

    Sun, Shen; Hayes-Gill, Barrie R.; He, Diwei; Zhu, Yiqun; Huynh, Nam T.; Morgan, Stephen P.

    2016-08-01

    Full field laser Doppler imaging (LDI) and single exposure laser speckle contrast imaging (LSCI) are directly compared using a novel instrument which can concurrently image blood flow using both LDI and LSCI signal processing. Incorporating a commercial CMOS camera chip and a field programmable gate array (FPGA) the flow images of LDI and the contrast maps of LSCI are simultaneously processed by utilizing the same detected optical signals. The comparison was carried out by imaging a rotating diffuser. LDI has a linear response to the velocity. In contrast, LSCI is exposure time dependent and does not provide a linear response in the presence of static speckle. It is also demonstrated that the relationship between LDI and LSCI can be related through a power law which depends on the exposure time of LSCI.

  14. Ankle-brachial pressure index estimated by laser Doppler in patients suffering from peripheral arterial obstructive disease.

    Science.gov (United States)

    Ludyga, Tomasz; Kuczmik, Waclaw B; Kazibudzki, Marek; Nowakowski, Przemyslaw; Orawczyk, Tomasz; Glanowski, Michal; Kucharzewski, Marcin; Ziaja, Damion; Szaniewski, Krzysztof; Ziaja, Krzysztof

    2007-07-01

    Ankle-brachial index (ABI) measurements are widely used for evaluating the functional state of circulation in the lower limbs. However, there is some evidence that the value of ABI does not accurately reflect the degree of walking impairment in symptomatic patients with peripheral arterial obstructive disease (PAOD). We investigated the diagnostic value of ABI estimated by means of laser Doppler flowmetry (IT) for evaluating limb ischemia. We wanted to know whether laser Doppler could be more sensitive than the Doppler method in predicting walking capacity in patients with stable intermittent claudication. We analyzed a group of 30 patients with intermittent claudication (Fontain II, II/III) who were admitted for reconstructive treatment. There were 21 men and 9 women, aged 46-74 (mean 61) years. All patients underwent the treadmill test, and pain-free walking distances were measured. In each patient, we measured ABI using the two different methods: Doppler ultrasound device (ABI-Doppler) and laser Doppler (ABI-laser Doppler). The claudication distances were 25-200 m (mean 73 +/- 50.2 m). ABI-Doppler was 0.2-0.7 (0.582 +/- 0.195). ABI-laser Doppler measurements were 0.581 (+/-0.218). A correlation was found between ABI-Doppler and claudication distance (r = 0.46, P = 0.009). Also, ABI-laser Doppler values significantly correlated with claudication distances (r = 0.536, P = 0.002). The ABI evaluated by laser Doppler correlated well with claudication distances in patients with PAOD. Comparison of Doppler and laser Doppler measurements used for determining ABI showed that both methods have similar predictive power for walking capacity; however, higher correlation was observed between claudication distances and ABI measured by laser Doppler flowmetry. ABI-laser Doppler measurements are easier, are quicker, and seem to be better suited for noncompliant patients. Further investigation should be undertaken to determine whether laser Doppler is superior to the Doppler

  15. Monostatic Doppler lidar using an Nd:YAG laser for wind-velocity measurement

    Science.gov (United States)

    Bersenev, V. I.; Kaptsov, L. N.; Priezzhev, A. V.

    1987-10-01

    A monostatic Doppler lidar using a CW Nd:YAG laser has been developed for measurements of wind velocity. A series of atmospheric measurements using this lidar was carried out. At medium turbulence levels, the limiting lidar range is 200 m. As compared with a CO2 Doppler lidar, the Nd:YAG lidar has a better spatial resolution, is more convenient to use, and does not require a cooled photodetector.

  16. Laser Doppler holographic microscopy in transmission: application to fish embryo imaging

    CERN Document Server

    Verrier, Nicolas; Gross, Michel

    2014-01-01

    We have extended Laser Doppler holographic microscopy to transmission geometry. The technique is validated with living fish embryos imaged by a modified upright bio-microcope. By varying the frequency of the holographic reference beam, and the combination of frames used to calculate the hologram, multimodal imaging has been performed. Doppler images of the blood vessels for different Doppler shifts, images where the flow direction is coded in RGB colors or movies showing blood cells individual motion have been obtained as well. The ability to select the Fourier space zone that is used to calculate the signal, makes the method quantitative.

  17. A detection method of laser doppler signal based on topo-logical contravariance

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yu-cun; LIU Hai-bin

    2009-01-01

    To detect the laser doppler signal, the unknown signal is tracked by the known signal using the concept of topological contravarisnce. The unknown topological space U and known space Mare founded, and then the unknown signal's trans-formation is tracked dynamically according to this mapping relationship between the two spaces. The system equation is obtained by gradient-descent method, and the conditions of stability are given by Poincare mapping. The proposed method is applied to measure the in-plane displacement signal of the solid 50 m away using laser doppler, signal The result proves that the method can detect laser doppler, signal accurately, its relative error is less than 0.7%.

  18. A laser Doppler study of gingival blood flow variations following periosteal stimulation.

    Science.gov (United States)

    Ambrosini, Pascal; Cherene, Sabine; Miller, Neal; Weissenbach, Michel; Penaud, Jacques

    2002-02-01

    Evaluation of the modifications occurring in human gingival blood flow following periosteal stimulation. Laser Doppler was used to measure the gingival blood flow (GBF). The reproducibility of the technique was validated by comparing measures made at intervals of 1 week. Sensitivity was verified by recording GBF before and after injection of an anesthetic containing a vasoconstrictor. Finally, 12 patients were subjected to GBF measurements before and 8 days after periosteal stimulation prior to gingival grafting. The laser Doppler accurately measured GBF. Measurements made at day 0 and day 7 were not statistically different (p=0.60). After injection of an anesthesic solution containing vasoconstrictor, the laser Doppler recorded a sharp decrease of the GBF (p=0.04). The patient that underwent periosteal stimulation showed statistically significant increases (p=0.02) in GBF before and 1 week post-stimulation. Periosteal stimulation induces significant increases in the GBF after 1 week.

  19. Analysis of Transitional and Turbulent Flow Through the FDA Benchmark Nozzle Model Using Laser Doppler Velocimetry.

    Science.gov (United States)

    Taylor, Joshua O; Good, Bryan C; Paterno, Anthony V; Hariharan, Prasanna; Deutsch, Steven; Malinauskas, Richard A; Manning, Keefe B

    2016-09-01

    Transitional and turbulent flow through a simplified medical device model is analyzed as part of the FDA's Critical Path Initiative, designed to improve the process of bringing medical products to market. Computational predictions are often used in the development of devices and reliable in vitro data is needed to validate computational results, particularly estimations of the Reynolds stresses that could play a role in damaging blood elements. The high spatial resolution of laser Doppler velocimetry (LDV) is used to collect two component velocity data within the FDA benchmark nozzle model. Two flow conditions are used to produce flow encompassing laminar, transitional, and turbulent regimes, and viscous stresses, principal Reynolds stresses, and turbulence intensities are calculated from the measured LDV velocities. Axial velocities and viscous stresses are compared to data from a prior inter-laboratory study conducted with particle image velocimetry. Large velocity gradients are observed near the wall in the nozzle throat and in the jet shear layer located in the expansion downstream of the throat, with axial velocity changing as much as 4.5 m/s over 200 μm. Additionally, maximum Reynolds shear stresses of 1000-2000 Pa are calculated in the high shear regions, which are an order of magnitude higher than the peak viscous shear stresses (<100 Pa). It is important to consider the effects of both viscous and turbulent stresses when simulating flow through medical devices. Reynolds stresses above commonly accepted hemolysis thresholds are measured in the nozzle model, indicating that hemolysis may occur under certain flow conditions. As such, the presented turbulence quantities from LDV, which are also available for download at https://fdacfd.nci.nih.gov/ , provide an ideal validation test for computational simulations that seek to characterize the flow field and to predict hemolysis within the FDA nozzle geometry.

  20. Analysis of Signal-to-Noise Ratio of the Laser Doppler Velocimeter

    DEFF Research Database (Denmark)

    Lading, Lars

    1973-01-01

    The signal-to-shot-noise ratio of the photocurrent of a laser Doppler anemometer is calculated as a function of the parameters which describe the system. It is found that the S/N is generally a growing function of receiver area, that few large particles are better than many small ones, and that g......The signal-to-shot-noise ratio of the photocurrent of a laser Doppler anemometer is calculated as a function of the parameters which describe the system. It is found that the S/N is generally a growing function of receiver area, that few large particles are better than many small ones...

  1. Two-beam nonlinear Kerr effect to stabilize laser frequency with sub-Doppler resolution

    CERN Document Server

    Martins, Weliton Soares; de Silans, Thierry Passerat; Oriá, Marcos; Chevrollier, Martine; 10.1364/AO.51.005080

    2012-01-01

    Avoiding laser frequency drifts is a key issue in many atomic physics experiments. Several techniques have been developed to lock the laser frequency using sub-Doppler dispersive atomic lineshapes as error signals in a feedback loop. We propose here a two-beam technique that uses non-linear properties of an atomic vapor around sharp resonances to produce sub-Doppler dispersive-like lineshapes that can be used as error signals. Our simple and robust technique has the advantage of not needing either modulation or magnetic fields.

  2. The influence of laser spot size on the micro-Doppler spectrum

    Science.gov (United States)

    Zhang, Dehua; Zhang, Haiyang; Zheng, Zheng; Yang, Hongzhi; Zhao, Changming; Yang, Suhui

    2015-08-01

    Micro-Doppler effect, which is induced by micro motion of target or any structure on the target, is a frequency modulation that generates sidebands about the target's Doppler frequency shift, such as mechanical vibration or rotation. When a target's motions incorporate micro motions, the radar echo signal will contain micro-Doppler characteristics related to these motions. Therefore, the micro-Doppler effect provides a new approach to obtain the dynamic properties of targets, which can be used to accomplish the detection and identification of targets, such as the identification of different types of helicopters. Scattering of the laser spot from a target surface modulates the Doppler signal, causes broadening of the signal spectrum, and, adds uncertainty to the signature analysis. A mathematic model of cone spin, which is a typical micro motion, is built first in this paper. Furthermore, an analyzed equation is deduced to predict the micro-Doppler spectral broadening of acquired medium current signals in situations of different laser spot size. It is found that the beam spot size on the target affects the resulting spectral broadening. Finally, an experiment based on the scaled model is performed to verify the simulation. A narrow-linewidth single frequency fiber laser is employed to detect the cone target at different laser spot size by coherent detection with constant detect distance and laser power. The experimental result shows that the beam spot size on the target affects the resulting spectral broadening caused by speckle, which corresponds to the simulation result. The experimental broadening was consistently greater than the theoretical broadening due to other effects that also contribute to the total broadening.

  3. A Reference Optical System of Laser Doppler Longitudinal Displacement Measurement

    Institute of Scientific and Technical Information of China (English)

    张存满; 赵洋; 李达成

    2001-01-01

    In this paper, a new reference optical system is put forward to achieve longitudinal displacement measurement. An optical grating is used for frequency mixing and getting high SNR signals in the measurement. Conditions and methods for getting Doppler beat signals are presented.The experiments indicate that this optical syetem can be used to measure the longitudinal displacement with high accuracy.

  4. Study on simulation and experiment of laser micro-Doppler effect for detecting complex vibration

    Science.gov (United States)

    Yuan, Shuai; Zhang, Juan; Liu, Mei-juan; Zhang, Jun

    2013-08-01

    The spectrum of radar signal will be modulated by moving target or vibration and turning part of the target, this is called micro-Doppler effect. It is a new way of using micro-Doppler effect to realize the feature extraction and target recognition. Because the complex vibration target has more complicated frequency component than the single frequency target, so it is very useful to do the research of simulation and experiment of laser micro-Doppler effect for detecting complex vibration. In this paper, the research on simulation and experiment of laser micro-Doppler effect for detecting complex vibration of moving target was developed based on the simulation research of micro-Doppler effect in lidar. Firstly, the geometry of complex vibrating target detection in radar was established. Secondly, the simulation and experiment signal sources were compared and also the returned signals in radar of the simulation and experiment were compared, the compared results showed that the two complex signal sources were very similar, and the frequency change trend of returned signals in radar was the same. Thirdly, joint time-frequency analysis method of the reassigned smoothed pseudo Wigner-Ville distribution (RSPWVD) was introduced to analyze the signals. The results showed that in RSPWVD, the waveform of the vibration target, the target vibration period, the Doppler frequency shift and the target's speed can be got. The simulation results and the experiment results got by the RSPWVD had the basically same frequency characteristics. So the RSPWVD can reflect very well the micro-Doppler characteristics of moving target's complex vibration. In conclusion it proved the validity of the simulated model, also it proved that using this time-frequency method to analyze the micro-Doppler signal of complex vibration was correct. And it laid the foundation of further using lidar to realize the classification and identification of target.

  5. Doppler- and recoil-free laser excitation of Rydberg states via three-photon transitions

    CERN Document Server

    Ryabtsev, I I; Tretyakov, D B; Entin, V M; Yakshina, E A

    2011-01-01

    Three-photon laser excitation of Rydberg states by three different laser beams can be arranged in a star-like geometry that simultaneously eliminates the recoil effect and Doppler broadening. Our analytical and numerical calculations for a particular laser excitation scheme 5S_{1/2}->5P_{3/2}->6S_{1/2}->nP in Rb atoms have shown that compared to the one- and two-photon laser excitation this approach provides much narrower line width and longer coherence time for both cold atom samples and hot vapors, if the intermediate one-photon resonances of the three-photon transition are detuned by more than respective single-photon Doppler widths. This method can be used to improve fidelity of Rydberg quantum gates and precision of spectroscopic measurements in Rydberg atoms.

  6. Doppler-free spectroscopy on Cs D$_1$ line with a dual-frequency laser

    CERN Document Server

    Hafiz, Moustafa Abdel; De Clercq, Emeric; Boudot, Rodolphe

    2016-01-01

    We report on Doppler-free laser spectroscopy in a Cs vapor cell using a dual-frequency laser system tuned on the Cs D$_1$ line. Using counter-propagating beams with crossed linear polarizations, an original sign-reversal of the usual saturated absorption dip and large increase in Doppler-free atomic absorption is observed. This phenomenon is explained by coherent population trapping (CPT) effects. The impact of laser intensity and light polarization on absorption profiles is reported in both single-frequency and dual-frequency regimes. In the latter, frequency stabilization of two diode lasers was performed, yielding a beat-note fractional frequency stability at the level of $3 \\times 10^{-12}$ at 1 s averaging time. These performances are about an order of magnitude better than those obtained using a conventional single-frequency saturated absorption scheme.

  7. Twente Optical Perfusion Camera: system overview and performance for video rate laser Doppler perfusion imaging

    NARCIS (Netherlands)

    M. Draijer; E. Hondebrink; T. van Leeuwen; W. Steenbergen

    2009-01-01

    We present the Twente Optical Perfusion Camera (TOPCam), a novel laser Doppler Perfusion Imager based on CMOS technology. The tissue under investigation is illuminated and the resulting dynamic speckle pattern is recorded with a high speed CMOS camera. Based on an overall analysis of the signal-to-n

  8. Multipoint laser Doppler vibrometry using holographic optical elements and a CMOS digital camera.

    Science.gov (United States)

    Connelly, Michael J; Szecówka, Przemyslaw M; Jallapuram, Raghavendra; Martin, Suzanne; Toal, Vincent; Whelan, Maurice P

    2008-02-15

    A laser Doppler vibrometer (LDV) is described in which holographic optical elements are used to provide the interferometer reference and object illumination beams. A complementary metal-oxide semiconductor camera, incorporating a digital signal processor, is used to carry out real-time signal processing of the interferometer output to allow multipoint LDV to be implemented.

  9. Burn imaging with a whole field laser Doppler perfusion imager based on a CMOS imaging array

    NARCIS (Netherlands)

    van Herpt, Heleen; Draijer, Matthijs; Hondebrink, Erwin; Nieuwenhuis, Marianne; Beerthuizen, Gerard; van Leeuwen, Ton; Steenbergen, Wiendelt

    2010-01-01

    Laser Doppler perfusion imaging (LDPI) has been proven to be a useful tool in predicting the burn wound outcome in an early stage. A major disadvantage of scanning beam LDPI devices is their slow scanning speed, leading to patient discomfort and imaging artifacts. We have developed the Twente Optica

  10. Monitoring Cerebral perfusion using near infrared spectroscopy and laser doppler flowmetry

    NARCIS (Netherlands)

    Klaessens, J.H.G.M.; Kolkman, R.G.M.; Hopman, J.C.W.; Hondebrink, E.; Liem, K.D.; Steenbergen, W.; Mul, de F.F.M.; Thijssen, J.M.

    2003-01-01

    This paper describes the simultaneous use of two, noninvasive, near-infrared techniques near-infrared spectroscopy (NIRS) and a continuous wave NIR laser Doppler flow system (LDF) to measure changes in the blood oxygenation, blood concentration and blood flow velocity in the brain. A piglet was used

  11. Monitoring cerebral perfusion using near-infrared spectroscopy and laser Doppler flowmetry.

    NARCIS (Netherlands)

    Klaessens, J.H.G.M.; Kolkman, R.G.; Hopman, J.C.W.; Hondebrink, E.; Liem, K.D.; Steenbergen, W.; Mul, F.F. de; Thijssen, J.M.

    2003-01-01

    This paper describes the simultaneous use of two, noninvasive, near-infrared techniques near-infrared spectroscopy (NIRS) and a continuous wave NIR laser Doppler flow system (LDF) to measure changes in the blood oxygenation, blood concentration and blood flow velocity in the brain. A piglet was used

  12. Laser Doppler anemometry measurements in a circulating fluidized bed of metal particles

    DEFF Research Database (Denmark)

    Ibsen, Claus Hübbe; Solberg, Tron; Hjertager, Bjørn Helge;

    2002-01-01

    Laser Doppler Anemometry (LDA) measurements were performed in a 1/9 scale model of a 12 MW circulating fluidized bed (CFB) boiler. The model was operated according to scaling laws. The 2D-LDA system used was positioned in two different ways to obtain the three velocity components u, v and w...

  13. Cost-effectiveness of laser Doppler imaging in burn care in the Netherlands

    NARCIS (Netherlands)

    M.J. Hop (M. Jenda); J. Hiddingh (J.); C.M. Stekelenburg (C.); H.C. Kuipers (Hester); E. Middelkoop (Esther); M. Nieuwenhuis (Marianne); S. Polinder (Suzanne); M.E. van Baar (Margriet)

    2013-01-01

    textabstractBackground: Early accurate assessment of burn depth is important to determine the optimal treatment of burns. The method most used to determine burn depth is clinical assessment, which is the least expensive, but not the most accurate.Laser Doppler imaging (LDI) is a technique with which

  14. Burn imaging with a whole field laser Doppler perfusion imager based on a CMOS imaging array

    NARCIS (Netherlands)

    van Herpt, Heleen; Draijer, Matthijs; Hondebrink, Erwin; Nieuwenhuis, Marianne; Beerthuizen, Gerard; van Leeuwen, Ton; van Leeuwen, Ton; Steenbergen, Wiendelt

    2010-01-01

    Laser Doppler perfusion imaging (LDPI) has been proven to be a useful tool in predicting the burn wound outcome in an early stage. A major disadvantage of scanning beam LDPI devices is their slow scanning speed, leading to patient discomfort and imaging artifacts. We have developed the Twente

  15. Cost-effectiveness of laser Doppler imaging in burn care in the Netherlands

    NARCIS (Netherlands)

    M.J. Hop (M. Jenda); J. Hiddingh (J.); C.M. Stekelenburg (C.); H.C. Kuipers (Hester); E. Middelkoop (Esther); M. Nieuwenhuis (Marianne); S. Polinder (Suzanne); M.E. van Baar (Margriet)

    2013-01-01

    textabstractBackground: Early accurate assessment of burn depth is important to determine the optimal treatment of burns. The method most used to determine burn depth is clinical assessment, which is the least expensive, but not the most accurate.Laser Doppler imaging (LDI) is a technique with which

  16. Twente Optical Perfusion Camera: system overview and performance for video rate laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Draijer, M.; Hondebrink, E.; van Leeuwen, T.; Steenbergen, W.

    2009-01-01

    We present the Twente Optical Perfusion Camera (TOPCam), a novel laser Doppler Perfusion Imager based on CMOS technology. The tissue under investigation is illuminated and the resulting dynamic speckle pattern is recorded with a high speed CMOS camera. Based on an overall analysis of the

  17. LASER-DOPPLER BLOOD FLOWMETRY USING 2 WAVELENGTHS - MONTE-CARLO SIMULATIONS AND MEASUREMENTS

    NARCIS (Netherlands)

    KOELINK, MH; DEMUL, FFM; GREVE, J; GRAAFF, R; DASSEL, ACM; AARNOUDSE, JG

    1994-01-01

    A new laser Doppler blood flowmeter for measuring skin perfusion is presented. The flowmeter consists of a probe that uses two different wavelengths and is able to measure at different depths. It may be used to distinguish the superficial microcirculation of the skin providing nutritional flow and t

  18. The influence of probe fiber distance on laser Doppler perfusion monitoring measurements

    NARCIS (Netherlands)

    Morales, F; Graaff, R; Smit, AJ; Gush, R; Rakhorst, G

    2003-01-01

    Laser Doppler perfusion monitoring (LDPM) is a noninvasive technique for monitoring skin microcirculation. The aim of this article was to investigate the influence of fiber separation on clinical LDPM measurements. A dual-channel LDPM system was used in combination with a probe that consists of two

  19. SELF-MIXING LASER-DOPPLER VELOCIMETRY OF LIQUID FLOW AND OF BLOOD PERFUSION IN TISSUE

    NARCIS (Netherlands)

    DEMUL, FFM; KOELINK, MH; WEIJERS, AL; GREVE, J; AARNOUDSE, JG; GRAAFF, R; DASSEL, ACM

    1992-01-01

    The velocimetry method of self-mixing, i.e., the feedback of Doppler-scattered light into the laser cavity, is used for the measurement of liquid flow and of blood perfusion in human tissue. The method is eIucidated by the registration of the blood perfusion of a finger under repeated occlusion of t

  20. Kombineret laser Doppler flowmetri og spectrophotometri som metode til vurdering af mikrocirculation

    DEFF Research Database (Denmark)

    Berggren Olsen, Mette; Sørensen, Hanne Birke; Houlind, Kim Christian

    Kombineret laser Doppler flowmetri og spectrophotometri som metode til vurdering af mikrocirculation Berggren, MB, reservelæge, Karkirurgisk Afdeling, Kolding, mette.marie.berggren.olsen@slb.regionsyddanmark.dk; Houlind, K, lektor, afdelingslæge, Ph.d., Karkirurgisk afdeling, Kolding, kim...

  1. Visual modeling of laser Doppler anemometer signals by moiré fringes.

    Science.gov (United States)

    Durst, F; Stevenson, W H

    1976-01-01

    This report describes the employment of moiré patterns to model visually interference phenomena in general and laser Doppler anemometer signals in particular. The modeling includes signals created in dual beam and reference beam anemometers by both single particles and particle pairs. The considerations are extended to visual modeling of multiparticle signals and the decay of signal quality in the presence of many particles. The fringe model of the laser Doppler anemometer is also considered, and moiré patterns are employed to demonstrate the interference fringes in the crossover region of two intersecting laser beams. Gaussian beam properties are taken into account to allow the effects of improperly designed optical systems to be studied. Instructions for using computer generated transparencies to produce the different moiré patterns are provided to allow the reader to study in detail the various interference phenomena described.

  2. Differential Laser Doppler based Non-Contact Sensor for Dimensional Inspection with Error Propagation Evaluation

    Directory of Open Access Journals (Sweden)

    Ketsaya Vacharanukul

    2006-06-01

    Full Text Available To achieve dynamic error compensation in CNC machine tools, a non-contactlaser probe capable of dimensional measurement of a workpiece while it is being machinedhas been developed and presented in this paper. The measurements are automatically fedback to the machine controller for intelligent error compensations. Based on a well resolvedlaser Doppler technique and real time data acquisition, the probe delivers a very promisingdimensional accuracy at few microns over a range of 100 mm. The developed opticalmeasuring apparatus employs a differential laser Doppler arrangement allowing acquisitionof information from the workpiece surface. In addition, the measurements are traceable tostandards of frequency allowing higher precision.

  3. Development of semiconductor laser based Doppler lidars for wind-sensing applications

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Hu, Qi; Pedersen, Christian

    2015-01-01

    We summarize the progress we have made in the development of semiconductor laser (SL) based Doppler lidar systems for remote wind speed and direction measurements. The SL emitter used in our wind-sensing lidar is an integrated diode laser with a tapered (semiconductor) amplifier. The laser source...... based wind sensors have a strong potential in a number of applications such as wind turbine control, wind resource assessment, and micrometeorology (e.g. as alternative to the construction of meteorological towers with anemometers and wind vanes)....

  4. Eye-safe,single-frequency pulsed all-fiber laser for Doppler wind lidar

    Institute of Scientific and Technical Information of China (English)

    Yuan Liu; Jiqiao Liu; Weibiao Chen

    2011-01-01

    @@ A single-frequency pulsed erbium-doped fiber(EDF)laser with master-oscillator Dower-amplifier comiguration at t bass nm is developed.A short-cavity,erbium-doped phosphate class fiber laser is utilized as a seeaer laser wntn a unewidtn of b khz and power of 40 mW.The seeder laser is modulated to be a pulse laser with a repetition rate of 10 kHz and pulse duration of 500 ns.The amplifier consists of two pre-amplifiers and one main amplifier.The detailed characteristics of the spectrum and linewidth of the amplifiers are presented.A pulse energy of 116 pJ and a linewidth of 1.1 MHz are obtained.This laser can be a candidate transmitter for an all-fiber Doppler wind lidar in the boundarv laver.%A single-frequency pulsed erbium-doped fiber (EDF) laser with master-oscillator power-amplifier configuration at 1533 nm is developed. A short-cavity, erbium-doped phosphate glass fiber laser is utilized as a seeder laser with a linewidth of 5 kHz and power of 40 mW. The seeder laser is modulated to be a pulse laser with a repetition rate of 10 kHz and pulse duration of 500 ns. The amplifier consists of two pre-amplifiers and one main amplifier. The detailed characteristics of the spectrum and linewidth of the amplifiers are presented. A pulse energy of 116 μJ and a linewidth of 1.1 MHz are obtained. This laser can be a candidate transmitter for an all-fiber Doppler wind lidar in the boundary layer.

  5. Experimental comparison of perfusion imaging systems using multi-exposure laser speckle, single-exposure laser speckle, and full-field laser Doppler

    Science.gov (United States)

    Thompson, Oliver; Bakker, Jimmy; Kloeze, Carla; Hondebrink, Erwin; Steenbergen, Wiendelt

    2012-03-01

    A variety of laser Doppler and laser speckle contrast systems have been constructed by various groups and companies, for commercial sale and for research. All rely on the same physical phenomenon - the dynamic laser speckle pattern generated by illuminating tissue with coherent light - but differ in details of system design, operation and analysis. We present a comparison between measurements made with three systems: a multi-exposure laser speckle contrast system built at Industrial Research Ltd, a commercial single-exposure laser speckle contrast system developed by Perimed AB (PSI NR) and the full-field laser Doppler camera built by the University of Twente (TOPCam). We compare the response to changing flows of all three systems. The systems are found to produce similar results for a variety of in-vivo and in-vitro measurements. Multi-exposure speckle contrast shows some advantages in information gained and insensitivity to static speckle, at the cost of increased complexity and measurement time.

  6. Detection on micro-Doppler effect based on 1550 nm laser coherent radar

    Science.gov (United States)

    Jun, Zhang; Yang, Sun; Zenghui, Cao; Tengfei, Sun; Tiantian, Zheng

    2014-01-01

    A laser coherent detection system of 1550 nm wavelength was presented, and experimental research on detecting micro-Doppler effect in a dynamic target was developed. In this paper, the return signal in the time domain is decomposed into a set of components in different wavelet-scales by multi-resolution analysis, and the components are associated with the vibrational motions in a target. The micro-Doppler signatures are extracted by applying the reconstruction (inverse wavelet transform). During the course of the final data processing frequency analysis and time-frequency analysis are applied to analyze the vibrational signals and estimate the motion parameters successfully. The experimental results indicate that the micro-Doppler information in a moving can be effectively detected, and tiny vibrational signatures also can be acquired effectively by wavelet multi-resolution analysis and time-frequency analysis.

  7. DETECTION ON MICRO-DOPPLER EFFECT BASED ON LASER COHERENT RADAR

    Institute of Scientific and Technical Information of China (English)

    Sun Yang; Zhang Jun

    2012-01-01

    A laser coherent detection system of 1550 nm wavelength was presented,and experimental research on detecting micro-Doppler effect in a dynamic target was developed.In the study,the return signal in the time domain is decomposed into a set of components in different wavelet scales by multi-resolution wavelet analysis,and the components are associated with the vibrational motions in a target.Then micro-Doppler signatures are extracted by applying the reconstruction.During the course of the final data processing frequency analysis and time-frequency analysis are applied to analyze the vibrational signals and estimate the motion parameters successfully.The experimental results indicate that the system can effectively detect micro-Doppler information in a moving target,and the tiny vibrational signatures also can be acquired effectively by wavelet multi-resolution analysis and time-frequency analysis.

  8. Laser Doppler vibrometry experiment on a piezo-driven slot synthetic jet in water

    Directory of Open Access Journals (Sweden)

    Broučková Zuzana

    2015-01-01

    Full Text Available The present study deals with a slot synthetic jet (SJ issuing from an actuator into quiescent surroundings and driven by a piezoceramic transducer. The actuator slot width was 0.36 mm, with a drive frequency proposed near the theoretical natural frequency of the actuator. The working fluid was water at room temperature. The present experiments used flow visualization (a laser-induced fluorescence technique and laser Doppler vibrometry methods. Flow visualization was used to identify SJ formation, to demonstrate its function, and to estimate SJ velocity. Laser Doppler vibrometry was used to quantify diaphragm displacement and refine operating parameters. Phase averaging yielded a spatial and temporal diaphragm deflection during the actuation period. Taking incompressibility and continuity into consideration, the velocity in the actuator slot and the Reynolds number of the SJ were evaluated as 0.21 m/s and 157, respectively. The present results confirmed a SJ actuator function at the resonance frequency of approximately 46 Hz, which corresponds closely with the theoretical evaluation. The laser Doppler vibrometry results corresponded closely with an estimation of SJ velocity by the present flow visualization.

  9. Laser Doppler flowmetry for bone blood flow measurements: helium-neon laser light attenuation and depth of perfusion assessment.

    Science.gov (United States)

    Nötzli, H P; Swiontkowski, M F; Thaxter, S T; Carpenter, G K; Wyatt, R

    1989-01-01

    Laser Doppler flowmetry (LDF) has been successfully used in clinical and experimental settings to evaluate bone perfusion but unanswered questions regarding its capabilities and limitations still remain. This study was undertaken to determine absorption of He-Ne laser light (632.8 nm) and maximum depth for flow assessment (threshold thickness) under optimal conditions in bone. Light transmittance in bovine bone samples of femora and tibia was measured after each step of grinding and depth of penetration calculated. The threshold thickness was obtained by placing the same samples in a flow chamber where a solution of 2% latex circulated beneath; flow was detected by a laser Doppler probe resting on top of the sample. The results showed a significantly higher depth of penetration for trabecular than for cortical bone. A regression analysis showed a high correlation between the inorganic fraction of the bone and the depth of penetration. The maximum depth at which the laser Doppler probe can evaluate flow in bone conditions was found to be 2.9 +/- 0.2 mm in cortical bone, 3.5 +/- 0.3 mm in bone covered by 1 mm cartilage and 3.5 +/- 0.2 mm in trabecular bone. The study showed the limitations of LDF in bone and their correlations to various bone properties.

  10. Speckle noise reduction of a dual-frequency laser Doppler velocimeter based on an optically injected semiconductor laser

    Science.gov (United States)

    Cheng, Chih-Hao; Lee, Jia-Wei; Lin, Tze-Wei; Lin, Fan-Yi

    2012-02-01

    We develop and investigate a dual-frequency Laser Doppler Velocimeter (DF-LDV) based on an optically injected semiconductor laser. By operating the laser in a period-one oscillation (P1) state, the laser can emit light with two coherent frequency components separated by about 11.25 GHz. Through optical heterodyning, the velocity of the target can be determined from the Doppler shift of the beat signal of the dual-frequency light. While the DF-LDV has the same advantages of good directionality and high intensity as in the conventional singlefrequency LDV (SF-LDV), having an effective wavelength in the range of microwave in the beat signal greatly reduces the speckle noise caused by the random phase modulation from the rough surface of the moving target. To demonstrate the speckle noise reduction, the Doppler shifted signals from a moving target covered by the plain paper are measured both from the SF-LDV and the DF-LDV. The target is rotated to provide a transverse velocity, where the speckle noise increases as the transverse velocity increases. The bandwidth of the Doppler signal obtained from the SF-LDV is increased from 4.7 kHz to 9.4 kHz as the transverse velocity increases from 0 m/s to 5 m/s. In contrast, the bandwidth obtained from the DF-LDV maintains at 0.09 Hz with or without the rotation limited by the linewidth of the P1 state used. By phase-locking the laser with a RF current modulation, the linewidth of the P1 state can be much reduced to further improve the velocity resolution and extend the detection range.

  11. [Laser Doppler flowmetry in newborn infants with low birth weight. The effect of differences in humidity on peripheral circulation].

    Science.gov (United States)

    Hanssler, L; Roll, C; Breukmann, H

    1992-01-01

    In a group of 10 low birth weight infants we measured skin temperature using infrared thermography and laser Doppler flow in central and peripheral regions of the body. After elevation of incubator humidity from 40 to 80% skin temperature of the foot rose significantly (p less than 0.01). At the same time there was a significant increase (p less than 0.05) of laser Doppler flow. Temperature and laser Doppler flow in the area of the abdomen did not show significant changes. Low birth weight infants are able to regulate peripheral blood flow after changes of ambient humidity. With the method of laser Doppler flowmetry thermoregulatory responses in the microvascular bed can be measured in these infants.

  12. Clearing of psoriasis documented by laser Doppler perfusion imaging contrasts remaining elevation of dermal expression levels of CD31

    NARCIS (Netherlands)

    Hendriks, A.G.M.; Kerkhof, van de P.C.M.; Jonge, de C.S.; Lucas, M.; Steenbergen, W.; Seyger, M.M.B.

    2015-01-01

    Background Vascular modifications represent a key feature in psoriatic plaques. Previous research with Laser Doppler Perfusion Imaging (LDPI) revealed a remarkable heterogeneity in the cutaneous perfusion within homogenous-appearing psoriatic lesions. Insights in the relation between perfusion durin

  13. Clearing of psoriasis documented by laser Doppler perfusion imaging contrasts remaining elevation of dermal expression levels of CD31

    NARCIS (Netherlands)

    Hendriks, A.G.M.; Kerkhof, P.C.M. van de; Jonge, C.S. de; Lucas, M.; Steenbergen, W.; Seyger, M.M.B.

    2015-01-01

    BACKGROUND: Vascular modifications represent a key feature in psoriatic plaques. Previous research with Laser Doppler Perfusion Imaging (LDPI) revealed a remarkable heterogeneity in the cutaneous perfusion within homogenous-appearing psoriatic lesions. Insights in the relation between perfusion duri

  14. Venous Small Bowel Infarction: Intraoperative Laser Doppler Flowmetry Discriminates Critical Blood Supply and Spares Bowel Length

    Directory of Open Access Journals (Sweden)

    S. A. Käser

    2012-01-01

    Full Text Available Introduction. In mesenteric infarction due to arterial occlusion, laser Doppler flowmetry and spectrometry are known reliable noninvasive methods for measuring microvascular blood flow and oxygen utilisation. Case Presentation. As an innovation we used these methods in a patient with acute extensive mesenteric infarction due to venous occlusion, occurring after radical right hemicolectomy. Aiming to avoid short bowel syndrome, we spared additional 110 cm of small bowel, instead of leaving only 80 centimetres of clinically viable small bowel in situ. The pathological examination showed only 5 mm of vital mucosa to be left distal to the dissection margin. No further interventions were necessary. Conclusion. Laser doppler flowmetry and spectrometry are potentially powerful methods to assist the surgeon’s decision-making in critical venous mesenteric perfusion, thus having an important impact on clinical outcome.

  15. Spectral analysis of laser-Doppler perfusion signal measured during thermal test.

    Science.gov (United States)

    Maniewski, R; Leger, P; Lewandowski, P; Liebert, A; Bendayan, P; Boccalon, H; Bajorski, L; Möller, K O

    1999-01-01

    The method of spectral analysis of laser-Doppler perfusion signal measured during thermal test is proposed. During three 20 min phases with 40, 5, and 40 degrees C of thermal test laser-Doppler perfusion signal was recorded. For each signal phase frequency spectra were calculated using the FFT method. Quantitative parameter Spectral Factor for results evaluation was proposed. In total 94 patients were measured: 69 with Raynaud's phenomenon and 25 normal subjects. Additionally in 18 Raynaud's patients the influence of Nifedipine was studied. Results suggest that proposed parameter is able to differentiate between Raynaud's patients and normal subjects and that is useful for evaluation of Nifedipine effectiveness. However, further studies are needed to improve the method to differentiate between primary and secondary Raynaud's patients.

  16. Development of a new laser Doppler velocimeter for the Ames High Reynolds Channel No. II

    Science.gov (United States)

    Seegmiller, H. L.; Bader, J. B.; Cooney, J. P.; De Young, A.; Donaldson, R. W., Jr.

    1985-01-01

    A new two-channel laser Doppler velocimeter developed for the Ames High Reynolds Channel No. 2 is described. Design features required for the satisfactory operation of the optical system in the channel environment are discussed. Fiber optics are used to transmit the megahertz Doppler signal to the photodetectors located outside the channel pressure vessel, and provision is made to isolate the optical system from pressure and thermal strain effects. Computer-controlled scanning mirrors are used to position the laser beams in the channel flow. Techniques used to seed the flow with 0.5-micron-diam polystyrene spheres avoiding deposition on the test-section windows and porous boundary-layer removal panels are described. Preliminary results are presented with a discussion of several of the factors affecting accuracy.

  17. Development of a new laser Doppler velocimeter for the Ames High Reynolds Channel No. 2

    Science.gov (United States)

    Seegmiller, H. L.; Bader, J. B.; Cooney, J. P.; Deyoung, A.; Donaldson, R. W., Jr.; Gunter, W. D., Jr.; Harrison, D. R.

    1985-01-01

    A new two-channel laser Doppler velocimeter developed for the Ames High Reynolds Channel No. 2 is described. Design features required for the satisfactory operation of the optical system in the channel environment are discussed. Fiber optics are used to transmit the megahertz Doppler signal to the photodetectors located outside the channel pressure vessel, and provision is made to isolate the optical system from pressure and thermal strain effects. Computer-controlled scanning mirrors are used to position the laser beams in the channel flow. Techniques used to seed the flow with 0.5-micron-diam polystyrene spheres avoiding deposition on the test-section windows and porous boundary-layer removal panels are described. Preliminary results are presented with a discussion of several of the factors affecting accuracy.

  18. Development of fiber optic laser Doppler velocimeter for measurement of local blood velocity

    Science.gov (United States)

    Ohba, Kenkich; Fujiwara, Noboru

    1993-08-01

    In order to measure the local velocity field in opaque fluid flows like blood flow, a new laser Doppler velocimeter having a pickup consisting of a small distributed index lens attached to the tips of two fibers which are joined side by side in parallel has been newly developed. The distributed index lens is the shape of a truncated cone. The flow field around this sensor has been measured very precisely by means of an ordinary LDV. The effect of turbidity of fluid on the quality of the laser Doppler signal from this sensor has been examined by experiments. As a result, it has been shown that this LDV sensor has a high signal-to-noise ratio, and that the disturbance against flow by the sensor is very small, and it is very promising as a velocity sensor for opaque or semi-opaque fluid flow like blood flow.

  19. Laser Doppler Vibrometer: Application of DOE/Taguchi Methodologies to Pyroshock Response Spectra

    Directory of Open Access Journals (Sweden)

    C. J. Litz

    1997-01-01

    Full Text Available Statistical methodologies were employed for measuring and analyzing the explosively induced transient responses of a flat steel plate excited with shock. The application of design of experiment methodology was made to structure and test a Taguchi L9(32 full factorial experimental matrix (which uses nine tests to study two factors, with each factor examined at three levels in which a helium-neon laser Doppler vibrometer and two piezocrystal accelerometers were used to monitor explosively induced vibrations ranging from 10 to 105 Hz on a 96 × 48 × 0.25 in. flat steel plate. Resulting conclusions were drawn indicating how these techniques aid in understanding the pyroshock phenomenon with respect to the effects and interrelationships of explosive-charge weight and location on the laser Doppler and contract accelerometer recording systems.

  20. Reproducibility of the capsaicin-induced dermal blood flow response as assessed by laser Doppler perfusion imaging

    OpenAIRE

    Van der Schueren, B. J.; Hoon, J.N.; Vanmolkot, F H; Van Hecken, A; Depre, M; Kane, S A; De Lepeleire, I.; Sinclair, S R

    2007-01-01

    What is already known about this subjectCapsaicin rapidly produces local neurogenic inflammation (characterized by oedema and erythema) when locally administered to the human skin by binding to the TRPV1 receptor present on dermal sensory nerve endings.In nonhuman primates, a pharmacodynamic assay has been described and validated using capsaicin-induced dermal vasodilation measured by laser Doppler perfusion imaging to assess calcitonin gene-related peptide antagonist activity.Laser Doppler p...

  1. Diagnosis of arterial occlusive disease of the lower extremities by laser Doppler flowmetry.

    Science.gov (United States)

    Van den Brande, P; Welch, W

    1988-01-01

    Laser Doppler Flowmetry offers the possibility of non-invasive and continuous recording of tissue blood flow. Skin blood flux in resting state and during postocclusive reactive hyperemia was measured at the pulpa of the toe in 21 normal lower limbs and in 58 limbs with arterial occlusive disease. Proper assessment of postischemic flux- and time- parameters (beginning of reactive hyperemia, peak flux, time of peak flux and duration of hyperemic flux) permits accurate separation of healthy and diseased limbs.

  2. Skin blood flow changes, measured by laser Doppler flowmetry, in the first week after birth

    NARCIS (Netherlands)

    Suichies, H.E.; Brouwer, C.; Aarnoudse, J.G.; Jentink, H.W.; de Mul, F.F.M.; Greve, Jan

    1990-01-01

    Changes in forehead skin blood flow were determined in 17 healthy, term newborns, using a fiberless diode laser Doppler flow meter (Diodopp). Measurements were carried out three times on each infant, at postnatal ages of 16.8 ± 7.4 h, 58.9 ± 6.2 h and 121.5 ± 14.2 h (mean ± S.D.), respectively. Skin

  3. Photoacoustic & pulsed laser-doppler monitoring of blood concentration and perfusion in tissue

    OpenAIRE

    Kolkman, Roy Gerardus Maria

    2002-01-01

    In medicine there are situations that require continuous bedside monitoring of perfusion and blood volume. Such a situation can occur when children are born prematurely. Those children have a high risk to develop a handicap, which is most likely caused by cerebral damage due to impaired brain perfusion. Monitoring cerebral perfusion can provide information for preventive treatment. In this thesis we have explored the potential of photoacoustics and laser Doppler flowmetry for measurement of c...

  4. Laser Doppler velocimetry applied to the measurement of local and global wind

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, J.M.; Forrester, P.A. (Royal Signals and Radar Establishment, Malvern (GB))

    1989-01-01

    The analysis of radiation scattered from naturally occurring aerosols carried along by the wind provides a powerful tool for the study of wind structure and enables the air flow to be studied from a single, non-perturbing, measuring station. In this paper, we outline the current status of wind measurement from ground-based, air borne and space platforms. The potential for using Laser Doppler Velocimetry on a range of applications with wind turbine generators is discussed. (author).

  5. A Systematic Review of the Evolution of Laser Doppler Techniques in Burn Depth Assessment

    Science.gov (United States)

    Fitzgerald O'Connor, Edmund; Philp, Bruce

    2014-01-01

    Aims. The introduction of laser Doppler (LD) techniques to assess burn depth has revolutionized the treatment of burns of indeterminate depth. This paper will systematically review studies related to these two techniques and trace their evolution. At the same time we hope to highlight current controversies and areas where further research is necessary with regard to LD imaging (LDI) techniques. Methods. A systematic search for relevant literature was carried out on PubMed, Medline, EMBASE, and Google Scholar. Key search terms included the following: “Laser Doppler imaging,” “laser Doppler flow,” and “burn depth.” Results. A total of 53 studies were identified. Twenty-six studies which met the inclusion/exclusion criteria were included in the review. Conclusions. The numerous advantages of LDI over those of LD flowmetry have resulted in the former technique superseding the latter one. Despite the presence of alternative burn depth assessment techniques, LDI remains the most favoured. Various newer LDI machines with increasingly sophisticated methods of assessing burn depth have been introduced throughout the years. However, factors such as cost effectiveness, scanning of topographically inconsistent areas of the body, and skewing of results due to tattoos, peripheral vascular disease, and anaemia continue to be sighted as obstacles to LDI which require further research. PMID:25180087

  6. Relationship of oscillating and average components of laser Doppler flowmetry signal

    Science.gov (United States)

    Mizeva, Irina; Frick, Peter; Podtaev, Sergey

    2016-08-01

    Signals from laser Doppler flowmeters widely used in intravital studies of skin blood flow include, along with a slowly varying average component, an oscillating part. However, in most clinical studies, pulsations are usually smoothed by data preprocessing and only the mean blood flow is analyzed. To reveal the relationship between average and oscillating perfusion components measured by a laser Doppler flowmeter, we examined the microvascular response to the contralateral cold pressor test recorded at two different sites of the hand: dorsal part of the arm and finger pad. Such a protocol makes it possible to provide a wide range of perfusion. The average perfusion always decreases during cooling, while the oscillating component demonstrates a differently directed response. The wavelet analysis of laser Doppler flowmetry (LDF) signals shows that the pulsatile component is nonlinearly related to the average perfusion. Under low perfusion, the amplitude of pulsations is proportional to its mean value, but, as perfusion increases, the amplitude of pulsations becomes lower. The type of response is defined by the basal perfusion and the degree of vasoconstriction caused by cooling. Interpretation of the results is complicated by the nonlinear transfer function of the LDF device, the contribution of which is studied using artificial examples.

  7. A new single-fibre laser Doppler flowmeter based on digital signal processing.

    Science.gov (United States)

    Cai, H; Pettersson, H; Rohman, H; Larsson, S E; Oberg, P A

    1996-10-01

    A new laser Doppler flowmeter, based on a personal computer with a digital signal processor for detecting the blood perfusion in skeletal muscle, was designed and evaluated. An infrared laser diode (750 nm) fed a single optical fibre, 400 microns in diameter, which was introduced into the muscle. A PC equipped with a digital processing unit was used for emulation of the laser Doppler algorithm and for presentation of the measurement results. The Doppler signal power spectral density and corresponding flow values were visualized on the computer screen continuously in real-time, and could also be saved on the hard disk for off-line analyses. The graphic-user interface supported by Labwindows software made the system easy to use. It is possible to alter in the software the signal processing and the ways in which the signals and results are presented. The new system was evaluated by using a flow model as well as a mechanical model. The model studies showed linear relationships between particle velocity and flow in the range of 0-5 mm s-1. The system was also tested in measurements of the blood flow in the brachioradial muscle, and was found to have advantages over our previously used systems.

  8. A Systematic Review of the Evolution of Laser Doppler Techniques in Burn Depth Assessment

    Directory of Open Access Journals (Sweden)

    Manaf Khatib

    2014-01-01

    Full Text Available Aims. The introduction of laser Doppler (LD techniques to assess burn depth has revolutionized the treatment of burns of indeterminate depth. This paper will systematically review studies related to these two techniques and trace their evolution. At the same time we hope to highlight current controversies and areas where further research is necessary with regard to LD imaging (LDI techniques. Methods. A systematic search for relevant literature was carried out on PubMed, Medline, EMBASE, and Google Scholar. Key search terms included the following: “Laser Doppler imaging,” “laser Doppler flow,” and “burn depth.” Results. A total of 53 studies were identified. Twenty-six studies which met the inclusion/exclusion criteria were included in the review. Conclusions. The numerous advantages of LDI over those of LD flowmetry have resulted in the former technique superseding the latter one. Despite the presence of alternative burn depth assessment techniques, LDI remains the most favoured. Various newer LDI machines with increasingly sophisticated methods of assessing burn depth have been introduced throughout the years. However, factors such as cost effectiveness, scanning of topographically inconsistent areas of the body, and skewing of results due to tattoos, peripheral vascular disease, and anaemia continue to be sighted as obstacles to LDI which require further research.

  9. New Laser Doppler Velocimetry with Wide Dynamic Range and Clear Directional Discrimination

    Institute of Scientific and Technical Information of China (English)

    GUI Hua-Qiao; L(U) Liang; HE De-Yong; XU Jun; XIE Jian-Ping; ZHAO Tian-Peng; WANG An-Ting; MING Hai

    2005-01-01

    @@ We present a new laser Doppler velocimetry based on self-mixing effect using a single longitudinal-mode verticalcavity surface-emitting laser modulated by a dynamic triangular current. It can indicate the direction of velocity without ambiguity in a wide dynamic range of 5.2-479.9mm/s. The accuracy of velocity measurement is better than 3.1% in the whole velocity range when a diffusing target is used for measurements. More interestingly, it works very well on different diffusing surfaces, even on a black glossy photographic paper.

  10. Monitoring laser treatment of port wine stains using phase-resolved optical Doppler tomography

    Science.gov (United States)

    Zhao, Yonghua; Chen, Zhongping; Saxer, Christopher E.; de Boer, Johannes F.; Majaron, Boris; Verkruysse, Wim; Nelson, J. Stuart

    2000-04-01

    We used a novel phase-resolved optical Doppler tomographic (ODT) technique, with very high flow velocity sensitivity and high spatial resolution, to image blood flow in port wine stain (PWS) birthmarks in human skin. The variance of blood flow velocity is used to locate the PWS vessels in addition to the regular ODT images. Our device combines an ODT system and laser so that PWS blood flow can be monitored in situ before and after treatment. To our knowledge, this is the first clinical application of ODT to provide a fast semi-quantitative evaluation of the efficacy of PWS laser therapy in situ and in real-time.

  11. Torsional vibration measurements on rotating shaft system using laser doppler vibrometer

    Science.gov (United States)

    Xiang, Ling; Yang, Shixi; Gan, Chunbiao

    2012-11-01

    In this work, a laser torsional vibrameter was used to measure the torsion vibration of a rotating shaft system under electrical network impact. Based on the principles of laser Doppler velocimetry, the laser torsional vibrometer (LTV) are non-contact measurement of torsional oscillation of rotating shafts, offering significant advantages over conventional techniques. Furthermore, a highly complex shafting system is analyzed by a modified Riccati torsional transfer matrix. The system is modeled as a chain consisting of an elastic spring with concentrated mass points, and the multi-segments lumped mass model is established for this shafting system. By the modified Riccati torsional transfer matrix method, an accumulated calculation is effectively eliminated to obtain the natural frequencies. The electrical network impacts can activize the torsional vibration of shaft system, and the activized torsion vibration frequencies contained the natural frequencies of shaft system. The torsional vibrations of the shaft system were measured under electrical network impacts in laser Doppler torsional vibrometer. By comparisons, the natural frequencies by measurement were consistent with the values by calculation. The results verify the instrument is robust, user friendly and can be calibrated in situ. The laser torsional vibrometer represents a significant step forward in rotating machinery diagnostics.

  12. A tunable Doppler-free dichroic lock for laser frequency stabilization

    Science.gov (United States)

    Singh, Vivek; Tiwari, V. B.; Mishra, S. R.; Rawat, H. S.

    2016-08-01

    We propose and demonstrate a laser frequency stabilization scheme which generates a dispersion-like tunable Doppler-free dichroic lock (TDFDL) signal. This signal offers a wide tuning range for lock point (i.e. zero-crossing) without compromising on the slope of the locking signal. The method involves measurement of magnetically induced dichroism in an atomic vapour for a weak probe laser beam in the presence of a counter-propagating strong pump laser beam. A simple model is presented to explain the basic principles of this method to generate the TDFDL signal. The spectral shift in the locking signal is achieved by tuning the frequency of the pump beam. The TDFDL signal is shown to be useful for locking the frequency of a cooling laser used for magneto-optical trap (MOT) for 87 Rb atoms.

  13. A tunable Doppler-free dichroic lock for laser frequency stabilization

    CERN Document Server

    Singh, Vivek; Mishra, S R; Rawat, H S

    2016-01-01

    We propose and demonstrate a laser frequency stabilization scheme which generates a dispersion-like tunable Doppler-free dichroic lock (TDFDL) signal. This signal offers a wide tuning range for lock point (i.e. zero-crossing) without compromising on the slope of the locking signal. The method involves measurement of magnetically induced dichroism in an atomic vapour for a weak probe laser beam in presence of a counter propagating strong pump laser beam. A simple model is presented to explain the basic principles of this method to generate the TDFDL signal. The spectral shift in the locking signal is achieved by tuning the frequency of the pump beam. The TDFDL signal is shown to be useful for locking the frequency of a cooling laser used for magneto-optcal trap (MOT) for $^{87}Rb$ atoms.

  14. UV laser approach to doppler tropospheric wind sounding from a satellite

    Science.gov (United States)

    McKay, Jack A.; Wilkerson, Thomas D.; Heller, Donald F.; Walling, John C.

    1995-12-01

    The possibility of direct detection of tropospheric wind speed Doppler shift with an ultraviolet laser is considered. The use of the UV eliminates all practical concerns of eye safety, permits the use of uncooled detectors, and yields enhanced aerosol and Rayleigh backscatter signals. The Rayleigh signal, which in the free troposphere can exceed the aerosol signal by three orders of magnitude, is itself a candidate for wind speed measurement, despite the Doppler broadening of this signal. The basis of this approach is a diode-pumped, frequency-doubled alexandrite laser, which offers very high electrical to optical energy efficiency, an estimated 9%, in generating UV output. Efficiency is critical for a satellite based lidar system due to the size, cost, and mass of solar power generation and waste heat disposal subsystems. Pumping of alexandrite with 680 nm laser diodes has been demonstrated. Narrow linewidth, high spectral purity, and high frequency stability have been obtained with laser diode injection seeding of a ring alexandrite laser. The tunable diode laser control allows tuning of the laser for spacecraft velocity compensation. The potential performance of a wind sounding lidar scaled to match the 300 W power capability of a mid-sized satellite is evaluated for the extremely weak aerosol conditions of the southern hemisphere oceans. A 20 W output laser system, with 1 m aperture telescope, at 350 km altitude, may yield measurement precisions better than plus or minus 3 m/s through most of the troposphere, deteriorating to plus or minus 10 m/s under extreme conditions. A Rayleigh backscatter system will yield plus or minus 3 m/s precision to 8 km altitude, plus or minus 5 m/s at 15 km, even with zero aerosol content.

  15. Laser Doppler measurement of relative blood velocity in the human optic nerve head.

    Science.gov (United States)

    Riva, C E; Grunwald, J E; Sinclair, S H

    1982-02-01

    The Doppler shift frequency spectrum (DSFS) of laser light scattered from red blood cells (RBCs) moving in the microcirculation of the optic nerve head has been recorded in normal volunteers by means of a fundus camera laser Doppler velocimeter. The width of the DSFS, which varies in proportion to the speed of the RBCs, has been characterized by a parameter alpha. With the use of a model for the scattering of light by tissue and RBCs and for the RBC velocity distribution, values of alpha recorded at normal intraocular pressure (IOP) suggest that the RBCs that contribute to the Doppler signal are flowing in capillaries. The parameter alpha was found to vary markedly with the IOP and with the phase of the ocular pressure pulse at elevated IOP. The return of the speed of RBCs toward normal, which is observed after a step increase of IOP above normal and after a step decrease below normal, has been attributed to an autoregulatory response of the optic nerve circulation.

  16. [Doppler effect on width of characteristic line in plasma induced by pulsed laser ablating Al].

    Science.gov (United States)

    Song, Yi-Zhong; He, An-Zhi

    2005-05-01

    Aluminum (Al) plasma was induced with a pulsed Nd: YAG laser beam ablating Al target in Ar. Time-resolved information of the plasma radiation was taken with time-resolved technique, and the spectra of the radiation were recorded with an optical multi-path analyzer (OMA III ), whereupon, time-resolved spectra of the plasma radiation induced by pulsed laser were acquired. Based on the experiment data, Al resonant double lines, Al I 396.15 nm, Al I 394.40 nm, were respectively fitted with Lorentz, Gauss and their linear integrated function (abbr. Integrated function), whereupon, Lorentz and Gauss elements were separated from the experiment data profile curve. By contrasting Lorentz with Gauss curve separated, it was found that the experiment curve mainly consisted of Lorentz element, a with little Gauss. By contrasting Lorentz with Integrated fitting curve for experiment data, a visual picture of the characteristic lines broadened by Doppler effect was exhibited. According to the visual picture, the increase of full half-high width of the characteristic line broadened by Doppler effect was estimated. It was about 2 x 10(-)3 -8 x 10(-3) nm, approximating the theoretical value 6.7 x 10(-)3 nm. As a result, Doppler effect on the width of characteristic lines in the plasma could be reasonably explained by curve fitting analysis and theoretical calculation.

  17. Quantitative measurement of blood flow dynamics in chorioallantoic membrane of chicken embryo using laser Doppler anemometry

    Science.gov (United States)

    Borozdova, M. A.; Stiukhina, E. S.; Sdobnov, A. A.; Fedosov, I. V.; Postnov, D. E.; Tuchin, V. V.

    2016-04-01

    We report the results on in ovo application of developed Laser Doppler Anemometer (LDA) device. The chorioallantoic membrane (CAM) of 9-13 days chicken embryos was used as a biological model that allows an easy access to both arterial and venous vessels of different size. The key point of our study was to find out how the periodic and aperiodic pulsations of blood flow (which are inevitable in living organism) will affect the LDA functions and measuring capability. Specifically, we (i) developed the technique to extract and refine the pulse rhythm from the signal received from a vessel, and (ii) analyzed the changes in power spectra of LDA signal that are caused by heart beating and considerably complicate the reliable measurement of Doppler shift. Our main conclusion is that the algorithm of LDA data processing need to be improved, and this possibly can be done by counting the information on current phase of cardiac cycle.

  18. Experimental and clinical application of laser doppler flowmetry in gastric and duodenal ulcerative bleedings

    Directory of Open Access Journals (Sweden)

    Afanasieva G.A.

    2011-12-01

    Full Text Available The research goal is to develop a new objective diagnostic method of prerecurrence syndrome that will prognose bleeding recurrence from gastroduodenal ulcers. Materials and methods. Method of laser Doppler flowmetry (LDF of the regional perfusion of tissue has been used. The experimental part has been done on 30 white laboratory rats. Characteristics of regional tissue perfusion in the simulation and laser hemostasis of bleeding have been studied. Gastroduodenal endoscopy has been performed with laser Doppler flowmetry (ELDF in clinical conditions to predict the recurrence of ulcerative bleeding. The prognostic method of gastroduodenal ulcerative bleeding was used in 58 patients hospitalized with such pathology and activity of bleeding Forrest II. Results. The study of microcirculation parameters and experimental hemostasis has showed the possibility of using LDF to measure its performance. Effective hemostasis has been accompanied by a significant decrease in perfusion. On the basis of microcirculation parameters in ulcerative bleeding, medical adrenaline test has been proposed for an objective verification pre-recurrence syndrome. To evaluate the effectiveness of endoscopic hemostasis perfusion has been measured before and after its implementation. Conclusion. ELDF has objectified the prognosis of ulcerative bleeding recurrence, verified pre-recurrence syndrome and evaluated the efficacy of endoscopic hemostasis

  19. Laser Doppler blood flow complementary metal oxide semiconductor imaging sensor with analog on-chip processing.

    Science.gov (United States)

    Gu, Quan; Hayes-Gill, Barrie R; Morgan, Stephen P

    2008-04-20

    A 4 x 4 pixel array with analog on-chip processing has been fabricated within a 0.35 mum complementary metal oxide semiconductor process as a prototype sensor for laser Doppler blood flow imaging. At each pixel the bandpass and frequency weighted filters necessary for processing laser Doppler blood flow signals have been designed and fabricated. Because of the space constraints of implementing an accurate omega(0.5) filter at the pixel level, this has been approximated using the "roll off" of a high-pass filter with a cutoff frequency set at 10 kHz. The sensor has been characterized using a modulated laser source. Fixed pattern noise is present that is demonstrated to be repeatable across the array and can be calibrated. Preliminary blood flow results on a finger before and after occlusion demonstrate that the sensor array provides the potential for a system that can be scaled to a larger number of pixels for blood flow imaging.

  20. Full-field laser Doppler imaging and its physiological significance for tissue blood perfusion

    Science.gov (United States)

    Binzoni, T.; Van DeVille, D.

    2008-12-01

    Using Monte Carlo simulations for a semi-infinite medium representing a skeletal muscle tissue, it is demonstrated that the zero- and first-order moments of the power spectrum for a representative pixel of a full-field laser-Doppler imager behave differently from classical laser-Doppler flowmetry. In particular, the zero-order moment has a very low sensitivity to tissue blood volume changes, and it becomes completely insensitive if the probability for a photon to interact with a moving red blood cell is above 0.05. It is shown that the loss in sensitivity is due to the strong forward scatter of the propagating photons in biological tissues (i.e., anisotropy factor g = 0.9). The first-order moment is linearly related to the root mean square of the red blood cell velocity (the Brownian component), and there is also a positive relationship with tissue blood volume. The most common physiological interpretation of the first-order moment is as tissue blood volume times expectation of the blood velocity (in probabilistic terms). In this sense, the use of the first-order moment appears to be a reasonable approach for qualitative real-time blood flow monitoring, but it does not allow us to obtain information on blood velocity or volume independently. Finally, it is shown that the spatial and temporal resolution trade-off imposed by the CMOS detectors, used in full-field laser-Doppler hardware, may lead to measurements that vary oppositely with the underlying physiological quantities. Further improvements on detectors' sampling rate will overcome this limitation.

  1. Full-field laser-Doppler imaging and its physiological significance for tissue blood perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Binzoni, T [Departement des Neurosciences Fondamentales, University of Geneva (Switzerland); Ville, D van de [Biomedical Imaging Group, Ecole Polytechnique Federale de Lausanne (EPFL) (Switzerland)], E-mail: Tiziano.Binzoni@medecine.unige.ch

    2008-12-07

    Using Monte Carlo simulations for a semi-infinite medium representing a skeletal muscle tissue, it is demonstrated that the zero- and first-order moments of the power spectrum for a representative pixel of a full-field laser-Doppler imager behave differently from classical laser-Doppler flowmetry. In particular, the zero-order moment has a very low sensitivity to tissue blood volume changes, and it becomes completely insensitive if the probability for a photon to interact with a moving red blood cell is above 0.05. It is shown that the loss in sensitivity is due to the strong forward scatter of the propagating photons in biological tissues (i.e., anisotropy factor g = 0.9). The first-order moment is linearly related to the root mean square of the red blood cell velocity (the Brownian component), and there is also a positive relationship with tissue blood volume. The most common physiological interpretation of the first-order moment is as tissue blood volume times expectation of the blood velocity (in probabilistic terms). In this sense, the use of the first-order moment appears to be a reasonable approach for qualitative real-time blood flow monitoring, but it does not allow us to obtain information on blood velocity or volume independently. Finally, it is shown that the spatial and temporal resolution trade-off imposed by the CMOS detectors, used in full-field laser-Doppler hardware, may lead to measurements that vary oppositely with the underlying physiological quantities. Further improvements on detectors' sampling rate will overcome this limitation.

  2. Doppler laser imaging predicts response to topical minoxidil in the treatment of female pattern hair loss.

    Science.gov (United States)

    McCoy, J; Kovacevic, M; Situm, M; Stanimirovic, A; Bolanca, Z; Goren, A

    2016-01-01

    Topical minoxidil is the only drug approved by the US FDA for the treatment of female pattern hair loss. Unfortunately, following 16 weeks of daily application, less than 40% of patients regrow hair. Several studies have demonstrated that sulfotransferase enzyme activity in plucked hair follicles predicts topical minoxidil response in female pattern hair loss patients. However, due to patients’ discomfort with the procedure, and the time required to perform the enzymatic assay it would be ideal to develop a rapid, non-invasive test for sulfotransferase enzyme activity. Minoxidil is a pro-drug converted to its active form, minoxidil sulfate, by sulfotransferase enzymes in the outer root sheath of hair. Minoxidil sulfate is the active form required for both the promotion of hair regrowth and the vasodilatory effects of minoxidil. We thus hypothesized that laser Doppler velocimetry measurement of scalp blood perfusion subsequent to the application of topical minoxidil would correlate with sulfotransferase enzyme activity in plucked hair follicles. In this study, plucked hair follicles from female pattern hair loss patients were analyzed for sulfotransferase enzyme activity. Additionally, laser Doppler velocimetry was used to measure the change in scalp perfusion at 15, 30, 45, and 60 minutes, after the application of minoxidil. In agreement with our hypothesis, we discovered a correlation (r=1.0) between the change in scalp perfusion within 60 minutes after topical minoxidil application and sulfotransferase enzyme activity in plucked hairs. To our knowledge, this is the first study demonstrating the feasibility of using laser Doppler imaging as a rapid, non-invasive diagnostic test to predict topical minoxidil response in the treatment of female pattern hair loss.

  3. Adaptive Model-Based Mine Detection/Localization using Noisy Laser Doppler Vibration Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E J; Xiang, N; Candy, J V

    2009-04-06

    The acoustic detection of buried mines is hampered by the fact that at the frequencies required for obtaining useful penetration, the energy is quickly absorbed by the ground. A recent approach which avoids this problem, is to excite the ground with a high-level low frequency sound, which excites low frequency resonances in the mine. These resonances cause a low-level vibration on the surface which can be detected by a Laser Doppler Vibrometer. This paper presents a method of quickly and efficiently detecting these vibrations by sensing a change in the statistics of the signal when the mine is present. Results based on real data are shown.

  4. Determination of air and hydrofoil pressure coefficient by laser doppler anemometry

    Directory of Open Access Journals (Sweden)

    Ristić Slavica S.

    2010-01-01

    Full Text Available Some results of experiments performed in water cavitation tunnel are presented. Pressure coefficient (Cp was experimentally determined by Laser Doppler Anemometry (LDA measurements. Two models were tested: model of airplane G4 (Super Galeb and hydrofoil of high speed axial pump. These models are not prepared for conventional pressure measurements, so that LDA is applied for Cp determination. Numerical results were obtained using a code for average Navier-Stokes equations solutions. Comparisons between computational and experimental results prove the effectiveness of the LDA. The advantages and disadvantages of LDA application are discussed. Flow visualization was made by air bubbles.

  5. Fiber-optic laser-Doppler anemometer microscope applied to the cerebral microcirculation in rats.

    Science.gov (United States)

    Seki, J; Sasaki, Y; Oyama, T; Yamamoto, J

    1996-01-01

    We have applied our developed fiber-optic laser-Doppler anemometer microscope (FLDAM) for the study of the cerebral microcirculation in the rat. The red cell velocity in single pial microvessels was successfully measured through a closed cranial window for the vessel diameter range from 7.8 to 230 microns. The temporal resolution of the FLDAM was sufficiently high to detect the pulsation in the arterioles. Arterio-venous distributions of the temporal mean red cell velocity and wall shear rate are also described.

  6. Acute radiation effects on cutaneous microvasculature: evaluation with a laser Doppler perfusion monitor

    Energy Technology Data Exchange (ETDEWEB)

    Amols, H.I.; Goffman, T.E.; Komaki, R.; Cox, J.D.

    1988-11-01

    Laser Doppler perfusion monitoring is a noninvasive technique for measuring blood flow in epidermal microvasculature that makes use of the frequency shift of light reflected from red blood cells. Measurements in patients undergoing radiation therapy show increases in blood flow of ten to 25 times baseline at doses above 50 Gy, and increases are observed with doses as low as 2 Gy. Follow-up measurements show rapid decreases in flow levels after completion of therapy, but levels remain elevated even at 1 year.

  7. Laser system for Doppler cooling of ytterbium ion in an optical frequency standard

    Energy Technology Data Exchange (ETDEWEB)

    Chepurov, S V; Lugovoy, A A; Kuznetsov, S N [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2014-06-30

    A laser system for Doppler cooling of ytterbium ion on the {sup 2}S{sub 1/2} → {sup 2}P{sub 1/2} transition in a single-ion optical frequency standard is developed. The second harmonic of a semiconductor laser with a wavelength of 739 nm is used for cooling. The laser frequency is doubled in a nonlinear BiBO crystal embedded in a ring resonator, which also serves as a reference for laser frequency stabilisation. Second-harmonic power of ∼100 μW is generated at a wavelength of 369.5 nm. Diode laser radiation is modulated by an electro-optic modulator at 14.75 GHz to generate a sideband exciting the {sup 2}S{sub 1/2} (F = 0) → {sup 2}P{sub 1/2} (F = 1) hyperfine component of the cooling transition that is not excited by resonant cooling light. The sideband relative intensity of a few percent proved to be sufficient to reduce the ion dwelling time in the {sup 2}S{sub 1/2} (F = 0) state to less than 10{sup -4} s and increase the cooling efficiency. (extreme light fields and their applications)

  8. A 3-component laser-Doppler velocimeter data acquisition and reduction system

    Science.gov (United States)

    Rodman, L. C.; Bell, J. H.; Mehta, R. D.

    1986-01-01

    This report describes a laser Doppler velocimeter capable of measuring all three components of velocity simultaneously in low-speed flows. All the mean velocities, Reynolds stresses, and higher-order products can then be evaluated. The approach followed is to split one of the colors used in a 2-D system, thus creating a third set of beams which is then focused in the flow from an off-axis direction. The third velocity component is computed from the known geometry of the system. In this report, the laser optical hardware and the data acquisition electronics are described in detail. In addition, full operating procedures and listings of the software (written in BASIC and assembly languages) are also included. Some typical measurements obtained with this system in a vortex/mixing layer interaction are presented and compared directly to those obtained with a cross-wire system.

  9. Experimental investigation of buried landmine detection using time division multiplexing of multibeam laser Doppler vibrometer channels

    Science.gov (United States)

    Burgett, Richard; Aranchuk, Vyacheslav; Aranchuk, Ina

    2012-06-01

    Producing vibration images of buried landmines using a multi-beam laser Doppler vibrometer (MB-LDV) operating from a stationary platform have been accomplished in the past. Detection from a continuously moving platform can reduce the time of detection compared to stop-and-stare measurement. However, there is a speed limitation, imposed by the required spatial and frequency resolution. NCPA proposed a concept of time division multiplexing (TDM) of laser beams of a MB-LDV to overcome that speed limitation. The system, based on 16-beam MB-LDV, has been built and experimentally tested at an Army test facility. Vibration velocity profiles of buried mines have been obtained at different system speeds. Algorithms for speckle noise reduction in continuously moving MB-LDV signals have been developed and explored. The results of the current data collection, recent past data collection as well as the results of the effectiveness of speckle noise reduction techniques are presented.

  10. Rotating blade vibration analysis using photogrammetry and tracking laser Doppler vibrometry

    Science.gov (United States)

    Gwashavanhu, Benjamin; Oberholster, Abrie J.; Heyns, P. Stephan

    2016-08-01

    Online structural dynamic analysis of turbomachinery blades is conventionally done using contact techniques such as strain gauges for the collection of data. To transfer the captured data from the sensor to the data logging system, installation of telemetry systems is required. This is usually complicated, time consuming and may introduce electrical noise into the data. In addition, contact techniques are intrusive by definition and can introduce significant local mass loading. This affects the integrity of the captured measurements. Advances in technology now allow for the use of optical non-contact methods to analyse the dynamics of rotating structures. These include photogrammetry and tracking laser Doppler vibrometry (TLDV). Various investigations to establish the integrity of photogrammetry measurements for rotating structures involved a comparison to data captured using accelerometers. Discrepancies that were noticed were attributed to the intrusive nature of the contact measurement technique. As an extended investigation, the presented work focuses on the validation of photogrammetry applied to online turbomachinery blade measurements, using TLDV measurements. Through a frequency based characterisation approach of the dynamics of the two scanning mirrors inside the scanning head of a scanning laser Doppler vibrometer (SLDV), TLDV is employed in developing a system that can be used to achieve a perfect circular scan with a Polytec SLDV, (PSV 300). Photogrammetry out-of-plane displacements of a laser dot focused on a specific point on a rotating blade are compared to displacements captured by the laser scanning system. It is shown that there is good correlation between the two measurement techniques when applied to rotating structures, both in the time and frequency domains. The presence of slight discrepancies between the two techniques after elimination of accelerometer based errors illustrated that the optical system noise floor of photogrammetry does

  11. Laser Doppler flowmeter and standardized thermal test in normals and Raynaud's phenomenon.

    Science.gov (United States)

    Boccalon, H J; Marguery, M C; Ginestet, M C; Puel, P F

    1987-01-01

    The diagnosis of Raynaud's phenomenon alone requires clinical investigations. To determine the stage of the disease, its etiology and pathophysiology, it seems desirable to perform noninvasive tests. Conclusions regarding control o the skin or muscle components of hand blood flow rely on evidence from separate measurements of skin or muscle blood flow. We described a standardized thermal provocation test, then respiratory maneuvers and pharmacological trials, to stimulate the microcirculatory control. The total cutaneous blood flow was continuously registered using a laser Doppler flowmeter. We conducted a prospective study on 100 subjects: 21 normal, 22 primary Raynaud's phenomenon (PRP), 26 secondary (SRP), 31 various microcirculatory diseases. The basal blood flow was lower in cases of severe SRP and acrocyanosis. In comparison with normals, RP cases present a less noticeable reaction to cold. Mild SRPs are more sensitive to cold and do not recover during warming up. Severe RPs are less sensitive to cold as they have a lower basal blood flow. Acrocyanosis cases are not sensitive to thermal variations. Post ischemic reactive hyperemia leads to a constant peak flow. Pharmacological assays were performed (nitroglycerine, Nifedipine) during permanent control of skin and muscle blood flow. Laser Doppler and provocation tests have no etiologic value in a Raynaud's phenomenon investigation; this methodology tries to elucidate the pathophysiology, the prognosis and the therapy of Raynaud's phenomenon.

  12. Agent-based station for on-line diagnostics by self-adaptive laser Doppler vibrometry

    Science.gov (United States)

    Serafini, S.; Paone, N.; Castellini, P.

    2013-12-01

    A self-adaptive diagnostic system based on laser vibrometry is proposed for quality control of mechanical defects by vibration testing; it is developed for appliances at the end of an assembly line, but its characteristics are generally suited for testing most types of electromechanical products. It consists of a laser Doppler vibrometer, equipped with scanning mirrors and a camera, which implements self-adaptive bahaviour for optimizing the measurement. The system is conceived as a Quality Control Agent (QCA) and it is part of a Multi Agent System that supervises all the production line. The QCA behaviour is defined so to minimize measurement uncertainty during the on-line tests and to compensate target mis-positioning under guidance of a vision system. Best measurement conditions are reached by maximizing the amplitude of the optical Doppler beat signal (signal quality) and consequently minimize uncertainty. In this paper, the optimization strategy for measurement enhancement achieved by the down-hill algorithm (Nelder-Mead algorithm) and its effect on signal quality improvement is discussed. Tests on a washing machine in controlled operating conditions allow to evaluate the efficacy of the method; significant reduction of noise on vibration velocity spectra is observed. Results from on-line tests are presented, which demonstrate the potential of the system for industrial quality control.

  13. Assesment of gingival microcirculation in anterior teeth using laser Doppler flowmetry

    Science.gov (United States)

    Canjau, Silvana; Miron, Mariana I.; Todea, Carmen D.

    2016-03-01

    Introduction: Evaluating the health status of the gingival tissue represents an important objective in the daily practice. Inflammation changes the microcirculatory and micromorphological dynamics of human gingiva. Aim: The purpose of this study was to evaluate the microcirculation in subjects with moderate gingivitis and healthy gingiva by using laser Doppler flowmetry (LDF). Material and Methods: Recordings of the gingival microcirculation (GM) were taken from 20 healthy gingival sites and from 20 sites with moderate gingivitis. The gingival blood flows in the gingivitis group before treatment was significantly different from those in the healthy gingiva group. Signals were recorded with the aid of a laser Doppler MoorLab instrument VMS-LDF2 probe VP3 10 mm S/N 2482. Three consecutive determinations of the GM were registered for each site, as follows: before the initial therapy, at 24 hours after the initial therapy and then, 7 days after the initial therapy. The data were processed using the statistical analysis software SPSS v16.0.1. Results: The results of this preliminary study showed statistically significant differences among the GM values recorded before and after the initial therapy. Conclusions: LDF could be a useful, noninvasive, sensitive, reproducible, and harmless method for measuring gingival blood flow (gingival microcirculation) in humans.

  14. Flow angle dependent photoacoustic Doppler power spectra under intensity-modulated continuous wave laser excitation

    Directory of Open Access Journals (Sweden)

    Yu Tong

    2016-02-01

    Full Text Available Photoacoustic Doppler (PAD power spectra showing an evident Doppler shift represent the major characteristics of the continuous wave-excited or burst wave-excited versions of PAD flow measurements. In this paper, the flow angle dependences of the PAD power spectra are investigated using an experiment setup that was established based on intensity-modulated continuous wave laser excitation. The setup has an overall configuration that is similar to a previously reported configuration, but is more sophisticated in that it accurately aligns the laser illumination with the ultrasound detection process, and in that it picks up the correct sample position. In the analysis of the power spectra data, we find that the background power spectra can be extracted by combining the output signals from the two channels of the lock-in amplifier, which is very useful for identification of the PAD power spectra. The power spectra are presented and analyzed in opposite flow directions, at different flow speeds, and at different flow angles. The power spectra at a 90° flow angle show the unique properties of symmetrical shapes due to PAD broadening. For the other flow angles, the smoothed power spectra clearly show a flow angle cosine relationship.

  15. Fractal Dimension Characterization of in-vivo Laser Doppler Flowmetry signals

    Science.gov (United States)

    Srinivasan, Gayathri; Sujatha, N.

    Laser Doppler Blood Flow meter uses tissue backscattered light to non-invasively assess the blood flow rate. qualitatively. As there is large spatial variability and the temporal heterogeneity in tissue microvasculature, the measured blood flow rate is expressed in relative units. A non-linear approach in order to understand the dynamics of the microcirculation led to the fractal characterization of the blood flow signals. The study presented in the paper aims to analyze the fractal behavior of Laser Doppler Flow (LDF) signals and to quantitatively estimate the fractal dimension of waveforms using Box-Counting method. The measured Fractal dimension is an estimate of temporal variability of tissue perfusion. The rate at which fractal dimension varies as a function of location between individuals, exhibits a weak correlation with time. Further studies with a larger number of subjects are necessary to test the generality of the findings and if changes in dimension are reproducible in given individuals. In conclusion, the fractal dimension determined by Box-counting method may be useful for characterizing LDF time series signals. Future experiments evaluating whether the technique can be used to quantify microvascular dysfunction, as commonly occurring in conditions such as Diabetes, Raynaud's phenomenon, Erythromelalgia and Achenbach syndrome needs to be evaluated.

  16. Laser Doppler flowmetry is valid for measurement of cerebral blood flow autoregulation lower limit in rats

    DEFF Research Database (Denmark)

    Tonnesen, Jan; Pryds, Anders; Larsen, Erik Hviid

    2005-01-01

    Laser Doppler flowmetry (LDF) is a recent technique that is increasingly being used to monitor relative changes in cerebral blood flow whereas the intra-arterial 133xenon injection technique is a well-established method for repeated absolute measurements of cerebral blood flow. The aim of this st...... CO2 challenge. Haemodilution influences the two methods differently causing relative overestimation of blood flow by the laser Doppler technique compared to the 133xenon method....... of this study was to validate LDF for assessment of cerebral autoregulation and CO2 reactivity with the 133xenon injection technique as the gold standard. Simultaneous measurements of cerebral blood flow (CBF) were collected by LDF (CBFLDF) and the 133xenon method (CBFXe) while (1) cerebral autoregulation...... was challenged by controlled systemic haemorrhage, or (2) cerebral blood flow was varied by manipulating the arterial partial pressure of CO2 (Pa,CO2). LDF slightly overestimated CBF under conditions of haemorrhagic shock and haemodilution caused by controlled haemorrhage (paired t test, P

  17. CO2 laser doppler systems for the measurement of atmospheric winds and turbulence

    Science.gov (United States)

    Huffaker, R. M.

    1975-01-01

    Two CO2 laser doppler systems developed by NASA and some results obtained with them are discussed. A continuous wave, monostatic system for short-range wind measurement is described, and direct comparisons between the data obtained with it and with a cup-anemometer/wind vane system and a hot-wire anemometer show excellent agreement between the systems. Improvements being made in three CW, CO2 laser doppler systems, including a filter bank for optimized signal processing and a versatile scanning system, are noted. A pulsed CO2 system for measuring clear air turbulence is described, and results of test performance on board a Convair 990 are presented. It is noted that while the system was able to measure air speed and turbulence, the range of its transmitter-atmosphere-receiver was lower than predicted, and a difference of about 20 to 30 dB existed between the actual and theoretical turbulence measurements. Factors that may account for this loss are listed.

  18. Simultaneous measurement of respiration and cardiac period in preterm infants by laser Doppler vibrometry

    Science.gov (United States)

    Scalise, Lorenzo; Marchionni, Paolo; Ercoli, Ilaria; Tomasini, Enrico Primo

    2012-06-01

    The paper presents an optical non-contact method for simultaneous measurement of the heart beat and respiration period, based on the assessment of the chest wall movements induced by the pumping action of the heart, and by inspiration/expiration acts of the lungs. The measurement method is applied on 40 patients recovered in a Neonatal Intensive Care Unit (NICU), where the operating conditions are often critical and the contact with the patient's skin needs to be minimized. The method proposed is based on optical recording of the movements of chest wall by means of a laser Doppler vibrometer directly pointed onto the left, frontal part of the thoracic surface. Data measured were compared with reference instrumentation; to reach this goal, the ECG and Laser Doppler Vibrometer (LDV) signals were simultaneously acquired to monitor the heart period (HP), while to measure respiration period (RP) signals from a spirometer and a LDV were collected simultaneously. After LDV signals decomposition, heart and respiration acts were detected and compared in term of beat per minute (bpm). HPs measured by the proposed method showed an uncertainty <6% (respect to ECG), while for RPs data an uncertainty of 3% (respect to spirometer data) was estimated. The proposed method has the intrinsic advantage to be totally without contact and to allow the simultaneous measurement of heart and respiration rate also in critical, clinical environments such as the NICU.

  19. Blood perfusion values of laser speckle contrast imaging and laser Doppler flowmetry: is a direct comparison possible?

    Science.gov (United States)

    Binzoni, Tiziano; Humeau-Heurtier, Anne; Abraham, Pierre; Mahe, Guillaume

    2013-05-01

    Laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) allow the monitoring of microvascular blood perfusion. The relationship between the measurements obtained by these two techniques remains unclear. In the present contribution, we demonstrate, experimentally and theoretically, that skin blood flow measurements obtained by LDF and LSCI techniques cannot be compared directly even after "classical" normalization procedure. This technical problem is generated by the nonlinear relationship existing between LDF and LSCI flow data. The experiments have been performed on five healthy voluntary subjects (forearm) by using repeated ischemia/reperfusion cycles to induce the necessary skin blood flow changes. LDF and LSCI data were simultaneously acquired on the same region of interest. Considering the importance of this problem from the clinical point of view, it is concluded that the definition of new corrected algorithms for LSCI is probably a mandatory step that must be taken into account if LDF and LSCI blood flow have to be compared.

  20. Interpretation of the two-components observed in high resolution X-ray diffraction {omega} scan peaks for mosaic ZnO thin films grown on c-sapphire substrates using pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Durand, O., E-mail: olivier.durand@insa-rennes.fr [Universite Europeenne de Bretagne, INSA, FOTON, UMR 6082, 20 avenue des Buttes de Coesmes, F-35708 RENNES (France); Letoublon, A. [Universite Europeenne de Bretagne, INSA, FOTON, UMR 6082, 20 avenue des Buttes de Coesmes, F-35708 RENNES (France); Rogers, D.J. [Nanovation SARL, 103 bis rue de Versailles, 91400 Orsay (France); SUPA, School of Physics and Astronomy, University of St. Andrews, St. Andrews, KY16 9SS (United Kingdom); Hosseini Teherani, F. [Nanovation SARL, 103 bis rue de Versailles, 91400 Orsay (France)

    2011-07-29

    X-ray scattering methods were applied to the study of thin mosaic ZnO layers deposited on c-Al{sub 2}O{sub 3} substrates using Pulsed Laser Deposition. High Resolution (HR) studies revealed two components in the {omega} scans (transverse scans) which were not resolved in conventional 'open-detector' {omega} rocking curves: a narrow, resolution-limited, peak, characteristic of long-range correlation, and a broad peak, attributed to defect-related diffuse-scattering inducing a limited transverse structural correlation length. Thus, for such mosaic films, the conventional {omega} rocking curve Full Width at Half Maximum linewidth was found to be ill-adapted as an overall figure-of-merit for the structural quality, in that the different contributions were not meaningfully represented. A 'Williamson-Hall like' integral breadth (IB) metric for the HR (00.l) transverse-scans was thus developed as a reliable, fast, accurate and robust alternative to the rocking curve linewidth for routine non-destructive testing of such mosaic thin films. For a typical ZnO/c-Al{sub 2}O{sub 3} film, the IB method gave a limited structural correlation length of 110 nm {+-} 9 nm. The results are coherent with a thin film containing misfit dislocations at the film-substrate interface.

  1. Instrument-independent flux units for laser Doppler perfusion monitoring assessed in a multi-device study on the renal cortex

    NARCIS (Netherlands)

    Petoukhova, AL; Steenbergen, W; Morales, F; Graaff, R; de Jong, ED; Elstrodt, JM; de Mul, FFM; Rakhorst, G

    2003-01-01

    To investigate the feasibility of instrument-independent perfusion units for laser Doppler flowmetry, a comparison was performed of two commercial fiberoptic laser Doppler perfusion monitors measuring the same flux situation for two different types of probes. In vivo measurements were performed on t

  2. Development of JSNS target vessel diagnosis system using laser Doppler method

    Science.gov (United States)

    Teshigawara, M.; Wakui, T.; Naoe, T.; Kogawa, H.; Maekawa, F.; Futakawa, M.; Kikuchi, K.

    2010-03-01

    When an intense pulsed proton beam with a power of 1 MW is irradiated to a mercury target, a pressure wave caused by the proton beam gives a vibration on the target vessel. Pitting damage also occurs on the target vessel, especially incident beam area, resulting in shortening of a life-time. It is very important to monitor the vibration of the target vessel from the view point of the life-time estimation. We developed the target vessel diagnosis system using laser Doppler method and successfully installed it in an actual pulsed spallation source. The diagnosis system consists of retro-reflecting corner-cube mirror (reflective mirror) on the target, mirror assembly in a reflector plug and laser source-detector. The newly developed reflective mirror, made by nickel, was installed by vacuum silver brazing on the target vessel to detect the target vibration. In order to pass the laser beam to the target vessel, a mirror assembly was installed inside the reflector plug. It is replaceable using a remote handling machine during a maintenance period. Nd-YAG laser beam (wave length: 533 nm) with the power of 50 mW was adopted to detect the target vibration. The first proton beam to the target in the spallation neutron source (JSNS) was provided on 30 May 2008. The first signal related to the target vibration was also detected by using this target vessel diagnosis system.

  3. Qualification Testing of Laser Diode Pump Arrays for a Space-Based 2-micron Coherent Doppler Lidar

    Science.gov (United States)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, Nathaniel R.; Barnes, Bruce W.; Singh, Upendra N.; Kavaya, Michael J.

    2007-01-01

    The 2-micron thulium and holmium-based lasers being considered as the transmitter source for space-based coherent Doppler lidar require high power laser diode pump arrays operating in a long pulse regime of about 1 msec. Operating laser diode arrays over such long pulses drastically impact their useful lifetime due to the excessive localized heating and substantial pulse-to-pulse thermal cycling of their active regions. This paper describes the long pulse performance of laser diode arrays and their critical thermal characteristics. A viable approach is then offered that allows for determining the optimum operational parameters leading to the maximum attainable lifetime.

  4. Two component theory and electron magnetic moment

    NARCIS (Netherlands)

    Veltman, M.J.G.

    1998-01-01

    The two-component formulation of quantum electrodynamics is studied. The relation with the usual Dirac formulation is exhibited, and the Feynman rules for the two-component form of the theory are presented in terms of familiar objects. The transformation from the Dirac theory to the two-component th

  5. Two component theory and electron magnetic moment

    NARCIS (Netherlands)

    Veltman, M.J.G.

    1998-01-01

    The two-component formulation of quantum electrodynamics is studied. The relation with the usual Dirac formulation is exhibited, and the Feynman rules for the two-component form of the theory are presented in terms of familiar objects. The transformation from the Dirac theory to the two-component

  6. He-Ne laser effects on blood microcirculation. An in vivo study through laser doppler flowmetry; Efeito do laser de helio neonio sobre a microcirculacao sanguinea durante a reparacao tecidual. Estudo in vivo por meio de fluxometria laser doppler

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, Silvia Cristina

    2002-07-01

    Blood microcirculation performs an important function in tissue repair process, as well as in pain control, allowing for greater oxygenation of the tissues and the accelerated expulsion of metabolic products, that may be contributing to pain. Low Intensity Laser Therapy (LILT) is widely used to promote healing, and there is an assumption that it is mechanism of action may be due to an enhancement of blood supply. The purpose of this study was to evaluate, using laser Doppler flowmetry (LDF), the stated effects caused by radiation emitted by a He-Ne laser ({lambda}=632.8 nm) on blood microcirculation during tissue repair. To this end, 15 male mice were selected and received a liquid nitrogen provoked lesion, above the dorsal region, and blood flow was measured periodically, during 21 days. Due to radiation emission by the LDF equipment, a control group was established to evaluate possible effects caused by this radiation on microcirculation. To evaluate the He-Ne laser effects, a 1.15 J/cm{sup 2} dose was utilized, with an intensity of 6 mW/cm{sup 2}. The results obtained demonstrate flow alterations, provoked by the lesion, and subsequent inflammatory response. There was no statistical difference between the studied groups. As per the analysis of the results there is no immediate effect due the radiation emitted by a He Ne laser on microcirculation, although a percentage increase was observed in day 7 on medium blood flow rate in irradiated specimens. New studies are necessary to validate the use of this wavelength, in order to promote beneficial alterations in blood supply in radiated areas. (author)

  7. Vasomotion in human skin before and after local heating recorded with laser Doppler flowmetry. A method for induction of vasomotion

    DEFF Research Database (Denmark)

    Kastrup, J; Bülow, J; Lassen, N A

    1989-01-01

    Rhythmical variations in blood cell flux in human skin have been studied using laser Doppler flowmetry. The fluctuations in blood cell flux could be divided into two different categories named alpha- and beta-oscillations with a median frequency of 6.8 min-1 and 1.5 min-1, respectively. The ampli...

  8. A comparison of measurements of cerebral blood flow in the rabbit using laser Doppler spectroscopy and radionuclide labelled microspheres.

    Science.gov (United States)

    Eyre, J A; Essex, T J; Flecknell, P A; Bartholomew, P H; Sinclair, J I

    1988-02-01

    Laser Doppler spectroscopy has been evaluated for the measurement of cerebral blood flow (CBF) by correlation with simultaneous measurements by radionuclide labelled microspheres. The experimental procedures were carried out on five anaesthetised rabbits. The cortical tissue was exposed by means of a small burr hole and illuminated by a helium neon laser (632.8 nm). Reflected light was detected using a silicon photodiode, and CBF was calculated continuously from the power of the frequency weighted Doppler spectrum in the reflected light. Three successive measurements of CBF were made using the microsphere technique. Following an initial baseline measurement, CBF was increased by an infusion of metaraminol and then reduced by controlled haemorrhage. Laser Doppler spectroscopy provided continuous monitoring of blood flow fluctuations and during the haemorrhage it was possible to demonstrate CBF autoregulation until the mean blood pressure fell below 6.7 kPa (50 mmHg). A regression analysis was performed between the simultaneous CBF measurements from the two techniques using a least squares best fit straight line analysis (r = 0.92, P less than 0.001). It was concluded that the flow computed from laser Doppler spectroscopy varied linearly with CBF and offers the unique advantage of continuous and instantaneous measurements even during nonsteady state flow.

  9. Evaluation of a new high power, wide separation laser Doppler probe : Potential measurement of deeper tissue blood flow

    NARCIS (Netherlands)

    Clough, Geraldine; Chipperfield, Andrew; Byrne, Christopher; de Mul, Frits; Gush, Rodney

    2009-01-01

    Objective: To compare the output from a novel high power, wide separation laser Doppler flow probe (DP1-V2-HP, 4 mm, with IRLD20) with that of a standard flow probe (DP1-V2, 0.5 mm, with DRT4) (Moor UK) and to explore its potential for use in the noninvasive measurement of blood flow in deeper tissu

  10. Perfusion of burn wounds assessed by Laser Doppler Imaging is related to burn depth and healing time

    NARCIS (Netherlands)

    Kloppenberg, FWH; Beerthuizen, GIJM; ten Duis, HJ

    Average perfusion in various burn wounds was assessed using Laser Doppler Imaging (LDI). The time necessary for a complete healing of the wound was compared to the results of the LDI measurements. A certain depth of burn was associated with a typical pattern of perfusion in the course of time. There

  11. Time Development Models for Perfusion Provocations Studied with Laser-Doppler Flowmetry, Applied to Iontophoresis and PORH

    NARCIS (Netherlands)

    De Mul, Frits F. M.; Blaauw, Judith; Smit, Ries J.; Rakhorst, Gerhard; Aarnoudse, Jan G.

    2009-01-01

    Objective: Clinical acceptance of laser-Doppler perfusion monitoring (LDPM) of microcirculation suffers from lack of quantitatively reliable signal data, due to varying tissue constitution, temperature, hydration, etc. In this article, we show that a novel approach using physiological models for res

  12. Perfusion of burn wounds assessed by Laser Doppler Imaging is related to burn depth and healing time

    NARCIS (Netherlands)

    Kloppenberg, FWH; Beerthuizen, GIJM; ten Duis, HJ

    2001-01-01

    Average perfusion in various burn wounds was assessed using Laser Doppler Imaging (LDI). The time necessary for a complete healing of the wound was compared to the results of the LDI measurements. A certain depth of burn was associated with a typical pattern of perfusion in the course of time. There

  13. Depside salts from Salvia miltiorrhiza improve myocardial microperfusion in rats using laser Doppler flowmetry

    Institute of Scientific and Technical Information of China (English)

    Xiao-fen LI; Yi-ping WANG

    2007-01-01

    Aim: To investigate the effects of depside salts from Salvia miltiorrhiza on myo-cardial microperfusion and systemic hemodynamics in open-chest anaesthetized Sprague-Dawley rats.Methods: Myocardial micropeffusion was measured by laser Doppler flowmetry with a needle probe; cardiac output (CO) was determined using ultrasonic Doppler flowmetry. Other hemodynamic parameters, including femoral artery blood pressure, cardiac inotropy, and systemic vascular resistance (SVR) were simultaneously recorded by the PowerLab system.Results: Intrave-nous administration of S miltiorrhiza depside salts resulted in a significant imme-diate increase in CO and cardiac inotropy, but a fall in SVR. S miltiorrhiza depside salts (30 mg/kg and 60 mg/kg) promoted cardiac index (CI) by 12.2%±6.3% (P<0.01vs baseline) and 20.1%±3.5% (P<0.01), respectively. Myocardial microperfusion maximally increased by 6.3%±2.9% (P<0.01) and 9.6%±4.0% (P<0.01) for 30 mg/kg and 60 mg/kg S miltiorrhiza depside salts, respectively.Conclusion: These results indicated that S miltiorrhiza depside salts improved myocardial micro-perfusion, as well as CO.

  14. SNR enhancement for composite application using multiple Doppler vibrometers based laser ultrasonic propagation imager

    Science.gov (United States)

    Truong, Thanh Chung; Lee, Jung Ryul

    2016-09-01

    In recent years, the technology of using laser ultrasonic propagation imaging for damage visualization of composite structures were applied to real-world applications. Among many choices of sensor for the Ultrasonic Propagation Imager, the laser interferometry has several advantages: it is non-invasive, and portable, and with extraordinarily long-range measurement. However, the critical issue with interferometry sensing is its low signal-to-noise ratio (SNR), where the background noise can mask the damage-induced waves and making it impossible to identify the damages, especially in composite structures. In this paper, we propose a hardware-based SNR enhancement technique using multiple Laser Doppler Vibrometers (LDVs). The out-of-plane mode of ultrasonic signals are measured by multiple LDVs at a common sensing point and then averaged in real time. We showed that the SNR enhancement in experiments was consistent with the theoretical prediction, and also the test results showed a clear improvement for damage visualization of structures using Ultrasonic Wave Propagation Imaging and Ultrasonic Wavenumber Imaging algorithms.

  15. Visualization of Guided Wave Propagation with Laser Doppler Vibrometer Scanning on Curved Surfaces

    Science.gov (United States)

    Hayashi, T.; Kojika, Y.; Kataoka, K.; Takikawa, M.

    2008-02-01

    In guided wave inspection for pipes, defect characterization is performed by echoes from defects. However, since detected signals become very complex due to mode conversion and multiple reflections, wave mechanics in a pipe with defects are not well studied. In this study, therefore, visualization technique for guided waves in a pipe is developed. In order to visualize guided wave propagation in a pipe, we need to scan an ultrasonic probe and measure ultrasonic waves at many points on a surface of a pipe. Position and posture of a laser doppler vibrometer are controlled by a robot arm, and ultrasonic vibration is detected at arbitrary points from arbitrary laser beam direction. Using the laser scanning technique, reflected guided waves from a shallow round defect was observed in the visualization results. From the defect, reflected waves propagated spirally in the oblique direction. From the view point of guided wave, the spiral waves were very high order modes that have not been measured in guided wave inspection. This result shows that such high order guided wave modes should be useful for defect characterization as well as low order modes.

  16. Dual-frequency laser Doppler velocimeter for speckle noise reduction and coherence enhancement.

    Science.gov (United States)

    Cheng, Chih-Hao; Lee, Chia-Wei; Lin, Tzu-Wei; Lin, Fan-Yi

    2012-08-27

    We study the characteristics of a dual-frequency laser Doppler velocimeter (DF-LDV) based on an optically injected semiconductor laser. The laser operated in a period-one (P1) dynamical state with two optical frequencies separated by 11.25 GHz is used as the dual-frequency light source. With a microwave beat signal carried by the light, the DF-LDV possesses both the advantages of good directionality, high intensity, and high spatial resolution from the light and low speckle noise and good coherence from the microwave, respectively. By phase-locking the two frequency components with a microwave signal, the coherence of the dual-frequency light source can be further improved and the detection range can be much extended. In this paper, velocity resolutions of the DF-LDV with different amounts of speckle noise and at different detection ranges are experimentally measured and analyzed. Compared with the conventional single-frequency LDV (SF-LDV), the velocity resolution of the DF-LDV is improved by 8 × 10(3) times from 2.5 m/s to 0.31 mm/s for a target with a longitudinal velocity vz = 4 cm/s, a transverse velocity vt = 5 m/s, and at a detection range of 108 m.

  17. Reference measurements on a Francis model turbine with 2D Laser-Doppler-Anemometry

    Science.gov (United States)

    Frey, A.; Kirschner, O.; Riedelbauch, S.; Jester-Zuerker, R.; Jung, A.

    2016-11-01

    To validate the investigations of a high-resolution CFD simulation of a Francis turbine, measurements with 2D Laser-Doppler-Anemometry are carried out. The turbine is operated in part load, where a rotating vortex rope occurs. To validate both, mean velocities and velocity fluctuations, the measurements are classified relative to the vortex rope position. Several acrylic glass windows are installed in the turbine walls such as upstream of the spiral case inlet, in the vaneless space and in the draft tube. The current investigation is focused on a measurement plane below the runner. 2D velocity components are measured on this whole plane by measuring several narrow spaced radial lines. To avoid optical refraction of the laser beam a plan parallel window is inserted in the cone wall. The laser probe is positioned with a 2D traverse system consisting of a circumferential rail and a radial aligned linear traverse. The velocity data are synchronized with the rotational frequency of the rotating vortex rope. The results of one measurement line show the dependency of the axial and circumferential velocities on the vortex rope position.

  18. Evaluation of the microcirculation in a rabbit hemorrhagic shock model using laser Doppler imaging.

    Science.gov (United States)

    Luo, Zhenchun; Wang, Pengfei; Zhang, An; Zuo, Guoqing; Zheng, Yuanyi; Huang, Yan

    2015-01-01

    The aim of this study is to evaluate the feasibility of Laser Doppler imaging (LDI) for noninvasive and dynamic assessment of hemorrhagic shock in a rabbit model. A rabbit model of hemorrhagic shock was generated and LDI of the microcirculation in the rabbit ears was performed before and at 0, 30, 60, and 90 min after hemorrhage. The CCD (Charge Coupled Device) image of the ears, the mean arterial pressure (MAP) and the heart rate (HR) were monitored. The mean LDI flux was calculated. The HR of rabbits was significantly (p 0.05). Both the flux numbers and the red-to-blue color changes on LDI imaging showed the reduction of the microcirculation. LDI imaging is a noninvasive and non-contact approach to evaluate the microcirculation and may offer benefits in the diagnosis and treatment of hemorrhage shock. Further studies are needed to confirm its effectiveness in clinical practice.

  19. Evaluation of the microcirculation in a rabbit hemorrhagic shock model using laser Doppler imaging.

    Directory of Open Access Journals (Sweden)

    Zhenchun Luo

    Full Text Available The aim of this study is to evaluate the feasibility of Laser Doppler imaging (LDI for noninvasive and dynamic assessment of hemorrhagic shock in a rabbit model. A rabbit model of hemorrhagic shock was generated and LDI of the microcirculation in the rabbit ears was performed before and at 0, 30, 60, and 90 min after hemorrhage. The CCD (Charge Coupled Device image of the ears, the mean arterial pressure (MAP and the heart rate (HR were monitored. The mean LDI flux was calculated. The HR of rabbits was significantly (p 0.05. Both the flux numbers and the red-to-blue color changes on LDI imaging showed the reduction of the microcirculation. LDI imaging is a noninvasive and non-contact approach to evaluate the microcirculation and may offer benefits in the diagnosis and treatment of hemorrhage shock. Further studies are needed to confirm its effectiveness in clinical practice.

  20. Combined medical diagnostic system with separated laser-Doppler and reflectance oximeter channels

    Science.gov (United States)

    Amzina, M. V.; Micheev, A. A.; Rogatkin, D. A.; Sidorov, V. V.

    2006-08-01

    On the basis of studying of opportunities of Reflectance Tissues Oximetry (RTO) as well as on the basis of RTO and Laser Doppler Flowmetry (LDF) comparative data, received in Moscow Regional Research and Clinical Institute "MONIKI" while patients with the peripheral blood microcirculation disorders were under examination, it was offered to unite the RTO and LDF techniques in a single diagnostic system. The new two-channel diagnostic system will contain the first LDF channel to measure the blood microcirculation parameters and the second RTO channel to register an average peripheral blood oxygenation. In the report the features of the new system design and a number of experimental data on correlation of RTO and LDF results are considered. The prospects of amalgamation of these two different techniques in a single diagnostic device are shown as well.

  1. EURISOL-DS Multi-MW Target: Cavitations detection by the a Laser Doppler Vibrometer

    CERN Document Server

    Cyril Kharoua, Yacine Kadi, Jacques Lettry, Laure Blumenfeld, Karel Samec (CERN)Knud Thomsen, Sergej Dementevjs, Rade Milenkovich (PSI)Anatoli Zik, Erik Platacis (IPUL)

    This technical note summarises the innovative measurement devices used within Task #2 of the European Isotope Separation On-Line Radioactive Ion Beam Facility Design Study (EURISOL-DS) to detect the occurrence of cavitation in liquid metal flowing inside the CGS target mock-up.During the METEX hydraulic experiment carried out at IPUL (Institute of Physics of the University of Latvia), a Laser Doppler Vibrometer was used to characterize the wall vibrations of the beam window at different flow regimes. A series of tests proved the high sensitivity of the LDV to detect the occurrence of cavitation in the liquid metal flowing inside the target. In this context, a dedicated test procedure was developed to establish the validity of using LDV for detecting the onset of cavitation.

  2. Endoscopic laser Doppler flowmetry in the experiment and in the bleeding gastric and duodenal ulcer clinic

    Science.gov (United States)

    Kapralov, S. V.; Shapkin, Y. G.; Lychagov, V. V.; Tuchin, V. V.

    2007-05-01

    One of the most complex problems of emergency surgery is the choice of surgical tactics to deal with bleeding peptic ulcer. Endoscopic hemostasis is prescribed to patients with continuing bleedings and prerelapse syndrome. But till nowdays the objective verification of the prerelapse condition had not been worked out. What is more there are no objective criteria to judge the effectiveness of the carried endohemostasis. The aim of the study was to work out a new objective diagnostic method of pre-recurrence syndrome that can be able to make prognosis for possible gastroduodenal ulcer bleeding recurrence more precise. Laser Doppler flowmetry was the method of studies the regional perfusion. The device used in this work was made at the Optics and Biophysics Department of Saratov State University.

  3. Taking laser Doppler vibrometry off the tripod: correction of measurements affected by instrument vibration

    Science.gov (United States)

    Halkon, Ben J.; Rothberg, Steve J.

    2017-04-01

    Laser Doppler vibrometers (LDVs) are now well-established as an effective non-contact alternative to traditional contacting transducers. Despite 30 years of successful applications, however, very little attention has been given to sensitivity to vibration of the instrument itself. In this paper, the sensitivity to instrument vibration is confirmed before development theoretically and experimentally of a practical scheme to enable correction of measurements for arbitrary instrument vibration. The scheme requires a pair of correction sensors with appropriate orientation and relative location, while using frequency domain processing to accommodate inter-channel time delay and signal integrations. Error reductions in excess of 30 dB are delivered in laboratory tests with simultaneous instrument and target vibration over a broad frequency range. Ultimately, application to measurement on a vehicle simulator experiencing high levels of vibration demonstrates the practical nature of the correction technique and its robustness in a challenging measurement environment.

  4. Laser-Doppler Velocimetry Measurements Inside a Backward Curved Centrifugal Fan

    Directory of Open Access Journals (Sweden)

    Tong-Miin Liou

    2001-01-01

    Full Text Available Laser-Doppler velocimetry (LDV measurements are presented of relative mean velocity and turbulence intensity components inside the impeller passage of a centrifugal fan with twelve backward curved blades at design, under-design, and over-design flow rates. Additional LDV measurements were also performed at the volute outlet to examine the uniformity of the outlet flow for the three selected flow rates. Complementary flow visualization results in the tongue region are further presented. It is found that the number of characteristic flow regions and the average turbulence level increase with decreasing air flow rate. For the case of under-design flow rate, there are a through-flow region on the suction side, a reverse flow region on the pressure side, and a shear layer region in between. The corresponding average turbulence intensity is as high as 9.1% of blade tip velocity.

  5. Measurement of the Resonant Characteristics of a Single Bubble Vibration by Using a Laser Doppler Vibrometer

    Science.gov (United States)

    Yoshikawa, Taisuke; Kotera, Hironori; Yoshida, Kenji; Koyama, Daisuke; Nakamura, Kentaro; Watanabe, Yoshiaki

    2011-07-01

    We constructed the experimental system with a laser Doppler vibrometer (LDV) for measuring the vibration of a single microbubble. It was demonstrated that the system enabled the capture of the vibration with an amplitude of nanometer order. We attempted to experimentally measure the resonant characteristics of a bubble attached to a wall by using the system. As a result, we succeeded in measuring the characteristics and evaluating the Q factor and the resonant radius at a driving frequency of 27.8 kHz, although these values are different from those predicted on the basis of the theory for a single free bubble. The LDV measurement system is expected to an effective tool for evaluating bubble vibrations with very small displacement amplitudes, such as the vibration of a microcapsule.

  6. Velocity distribution measurements in a fishway like open channel by Laser Doppler Anemometry (LDA)

    Science.gov (United States)

    Sayeed-Bin-Asad, S. M.; Lundström, T. S.; Andersson, A. G.; Hellström, J. G. I.

    2016-03-01

    Experiments in an open channel flume with placing a vertical half cylinder barrier have been performed in order to investigate how the upstream velocity profiles are affected by a barrier. An experimental technique using Laser Doppler Velocimetry (LDV) was adopted to measure these velocity distributions in the channel for four different discharge rates. Velocity profiles were measured very close to wall and at 25, 50 and 100 mm upstream of the cylinder wall. For comparing these profiles with well-known logarithmic velocity profiles, velocity profiles were also measured in smooth open channel flow for all same four discharge rates. The results indicate that regaining the logarithmic velocity profiles upstream of the half cylindrical barrier occurs at 100 mm upstream of the cylinder wall.

  7. Velocity distribution measurements in a fishway like open channel by Laser Doppler Anemometry (LDA

    Directory of Open Access Journals (Sweden)

    Sayeed-Bin-Asad S.M.

    2016-01-01

    Full Text Available Experiments in an open channel flume with placing a vertical half cylinder barrier have been performed in order to investigate how the upstream velocity profiles are affected by a barrier. An experimental technique using Laser Doppler Velocimetry (LDV was adopted to measure these velocity distributions in the channel for four different discharge rates. Velocity profiles were measured very close to wall and at 25, 50 and 100 mm upstream of the cylinder wall. For comparing these profiles with well-known logarithmic velocity profiles, velocity profiles were also measured in smooth open channel flow for all same four discharge rates. The results indicate that regaining the logarithmic velocity profiles upstream of the half cylindrical barrier occurs at 100 mm upstream of the cylinder wall.

  8. Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements

    Science.gov (United States)

    Phillips, Justin P.; Cibert-Goton, Vincent; Langford, Richard M.; Shortland, Peter J.

    2013-03-01

    Animal models are widely used to investigate the pathological mechanisms of spinal cord injury (SCI), most commonly in rats. It is well known that compromised blood flow caused by mechanical disruption of the vasculature can produce irreversible damage and cell death in hypoperfused tissue regions and spinal cord tissue is particularly susceptible to such damage. A fiberoptic photoplethysmography (PPG) probe and instrumentation system were used to investigate the practical considerations of making measurements from rat spinal cord and to assess its suitability for use in SCI models. Experiments to assess the regional perfusion of exposed spinal cord in anesthetized adult rats using both PPG and laser Doppler flowmetry (LDF) were performed. It was found that signals could be obtained reliably from all subjects, although considerable intersite and intersubject variability was seen in the PPG signal amplitude compared to LDF. We present results from 30 measurements in five subjects, the two methods are compared, and practical application to SCI animal models is discussed.

  9. Doppler Spectrometry for Ultrafast Temporal Mapping of Density Dynamics in Laser-Induced Plasmas

    Science.gov (United States)

    Mondal, S.; Lad, Amit D.; Ahmed, Saima; Narayanan, V.; Pasley, J.; Rajeev, P. P.; Robinson, A. P. L.; Kumar, G. Ravindra

    2010-09-01

    We present high resolution measurements of the ultrafast temporal dynamics of the critical surface in moderately overdense, hot plasma by using two-color, pump-probe Doppler spectrometry. Our measurements clearly capture the initial inward motion of the plasma inside the critical surface of the pump laser which is followed by outward expansion. The measured instantaneous velocity and acceleration profiles are very well reproduced by a hybrid simulation that uses a 1D electromagnetic particle-in-cell simulation for the initial evolution and a hydrodynamics simulation for the later times. The combination of high temporal resolution and dynamic range in our measurements clearly provides quantitative unraveling of the dynamics in this important region, enabling this as a powerful technique to obtain ultrafast snapshots of plasma density and temperature profiles for providing benchmarks for simulations.

  10. Time-resolved fuel injector flow characterisation based on 3D laser Doppler vibrometry

    CERN Document Server

    Crua, Cyril

    2015-01-01

    In order to enable investigations of the fuel flow inside unmodified injectors, we have developed a new experimental approach to measure time-resolved vibration spectra of diesel nozzles using a three dimensional laser vibrometer. The technique we propose is based on the triangulation of the vibrometer and fuel pressure transducer signals, and enables the quantitative characterisation of quasi-cyclic internal flows without requiring modifications to the injector, the working fluid, or limiting the fuel injection pressure. The vibrometer, which uses the Doppler effect to measure the velocity of a vibrating object, was used to scan injector nozzle tips during the injection event. The data were processed using a discrete Fourier transform to provide time-resolved spectra for valve-closed-orifice, minisac and microsac nozzle geometries, and injection pressures ranging from 60 to 160MPa, hence offering unprecedented insight into cyclic cavitation and internal mechanical dynamic processes. A peak was consistently f...

  11. Cost-effectiveness of laser Doppler imaging in burn care in the Netherlands

    Directory of Open Access Journals (Sweden)

    Hop M Jenda

    2013-02-01

    Full Text Available Abstract Background Early accurate assessment of burn depth is important to determine the optimal treatment of burns. The method most used to determine burn depth is clinical assessment, which is the least expensive, but not the most accurate. Laser Doppler imaging (LDI is a technique with which a more accurate (>95% estimate of burn depth can be made by measuring the dermal perfusion. The actual effect on therapeutic decisions, clinical outcomes and the costs of the introduction of this device, however, are unknown. Before we decide to implement LDI in Dutch burn care, a study on the effectiveness and cost-effectiveness of LDI is necessary. Methods/design A multicenter randomised controlled trial will be conducted in the Dutch burn centres: Beverwijk, Groningen and Rotterdam. All patients treated as outpatient or admitted to a burn centre within 5 days post burn, with burns of indeterminate depth (burns not obviously superficial or full thickness and a total body surface area burned of ≤ 20% are eligible. A total of 200 patients will be included. Burn depth will be diagnosed by both clinical assessment and laser Doppler imaging between 2–5 days post burn in all patients. Subsequently, patients are randomly divided in two groups: ‘new diagnostic strategy’ versus ‘current diagnostic strategy’. The results of the LDI-scan will only be provided to the treating clinician in the ‘new diagnostic strategy’ group. The main endpoint is the effect of LDI on wound healing time. In addition we measure: a the effect of LDI on other patient outcomes (quality of life, scar quality, b the effect of LDI on diagnostic and therapeutic decisions, and c the effect of LDI on total (medical and non-medical costs and cost-effectiveness. Discussion This trial will contribute to our current knowledge on the use of LDI in burn care and will provide evidence on its cost-effectiveness. Trial registration NCT01489540

  12. Setup and Test of a Laser Doppler Velocimeter for Investigations of Flow Behaviour of Polymer Melts

    Science.gov (United States)

    Schmidt, M.; Wassner, E.; Münstedt, H.

    1999-12-01

    The flow behaviour of a low-density polyethylene melt is investigated in a specifically developed flow channel by means of Laser Doppler Velocimetry (LDV). The used flow channel is a slit die with a planar contraction of 14:1. The investigation of the velocity fields was performed in the steady state of flow. The optics of the LDV system as well as the used frequency analyser proved to be reliable for measurements of velocities down to 250μm/s. By adding TiO2 tracer particles to the pellets the signal quality as well as the signal frequency were improved. It is demonstrated that the Laser Doppler Velocimeter is suited to detect velocities of polymer melts with an error of a few per cent by comparing the measured volume flow rate to the directly determined mass flow rate. Using simple fluid mechanics the viscosity function is obtained by measuring only one velocity profile within the fully developed flow in the slit die. Over a wide range of shear rates the viscosity function obtained via LDV measurement corresponds with the viscosity function which was determined by the classical mass-flow-rate method. Both resulting viscosity functions were additionally checked by performing measurements with a capillary rheometer. The LDV setup described in this paper is a powerful experimental tool to investigate the flow behaviour of polymer melts. Its accuracy and the high spatial and temporal resolution opens a way to get more quantitative insight into the flow of polymer melts and to check the validity of model calculations.

  13. Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

    Science.gov (United States)

    Campo, Adriaan; Dirckx, Joris

    2014-05-01

    It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

  14. Laser Doppler vibrometry for assessment of arteriosclerosis: A first step towards validation

    Energy Technology Data Exchange (ETDEWEB)

    Campo, Adriaan; Dirckx, Joris [University of Antwerp, Laboratory of Biomedical Physics, Groenenborgerlaan 171 2020 Antwerp (Belgium)

    2014-05-27

    It has been shown that in cardiovascular risk management, stiffness of large arteries has a very good predictive value for cardiovascular disease and mortality. This parameter can be estimated from the pulse wave velocity (PWV) measured between the common carotid artery (CCA) in the neck and femoral artery (FA) in the groin. However PWV can also be measured locally in the CCA, using non-invasive methods such as ultrasound (US) or laser Doppler vibrometry (LDV). Potential of the latter approach was already explored in previous research, and in this work a first step towards clinical validation is made. 50 hypertension II/III patients aged between 30 and 65 participate in the study. Patients were asked to remain sober for 4 hours prior to the measurements. The trajectory of the CCA in the neck was determined by a trained clinician guided by an US probe. 3 laser Doppler vibrometer (LDV) systems were aimed along the CCA. PWV was then calculated from the distance between beams and the time-shift between waveforms. Immediately after LDV measurements, PWV was measured with US. Additionally, carotid-femoral PWV was measured. As a validation, PWV results of the different techniques were compared with each other, and with medical background of the test subjects. Since data acquisition is still ongoing, data from only 20 patients will be discussed. No trends between measurement methods for PWV are apparent. However, a positive trend was detected between PWV as measured with LDV and blood pressure. More data, including additional experiments will be needed to verify this observation.

  15. Efficient sub-Doppler transverse laser cooling of an indium atomic beam

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae-Ihn

    2009-07-23

    Laser cooled atomic gases and atomic beams are widely studied samples in experimental research in atomic and optical physics. For the application of ultra cold gases as model systems for e.g. quantum many particle systems, the atomic species is not very important. Thus this field is dominated by alkaline, earthalkaline elements which are easily accessible with conventional laser sources and have convenient closed cooling transition. On the other hand, laser cooled atoms may also be interesting for technological applications, for instance for the creation of novel materials by atomic nanofabrication (ANF). There it will be important to use technologically relevant materials. As an example, using group III atoms of the periodical table in ANF may open a route to generate fully 3D structured composite materials. The minimal requirement in such an ANF experiment is the collimation of an atomic beam which is accessible by one dimensional laser cooling. In this dissertation, I describe transverse laser cooling of an Indium atomic beam. For efficient laser cooling on a cycling transition, I have built a tunable, continuous-wave coherent ultraviolet source at 326 nm based on frequency tripling. For this purpose, two independent high power Yb-doped fiber amplifiers for the generation of the fundamental radiation at {lambda}{sub {omega}} = 977 nm have been constructed. I have observed sub-Doppler transverse laser cooling of an Indium atomic beam on a cycling transition of In by introducing a polarization gradient in the linear-perpendicular-linear configuration. The transverse velocity spread of a laser-cooled In atomic beam at full width at half maximum was achieved to be 13.5{+-}3.8 cm/s yielding a full divergence of only 0.48 {+-} 0.13 mrad. In addition, nonlinear spectroscopy of a 3-level, {lambda}-type level system driven by a pump and a probe beam has been investigated in order to understand the absorption line shapes used as a frequency reference in a previous two

  16. Monostatic coaxial 1.5 μm laser Doppler velocimeter using a scanning Fabry-Perot interferometer

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2013-01-01

    and receiver optics share a common axis reduces the number of components and greatly simplifies the optical alignment. However, the sensitivity to unwanted backreflections is increased. To circumvent this problem, we employ a custom optical circulator design which compared to commercial fiber-optic circulator......We present a laser Doppler velocimeter (LDV) in monostatic coaxial arrangement consisting of off-the-shelf telecom-grade components: a single frequency laser (wavelength λ = 1.5 μm) and a high-finesse scanning Fabry-Perot interferometer (sFPI). In contrast to previous 1.5 μm LDV systems based...... on heterodyne detection, our sFPI-LDV has the advantages of having large remote sensing range not limited by laser coherence, high velocity dynamic range not limited by detector bandwidth and inherent sign discrimination of Doppler shift. The more optically efficient coaxial arrangement where transmitter...

  17. Comparison of near-infrared spectroscopy and laser Doppler flowmetry for detecting decreased hepatic inflow in the porcine liver.

    Science.gov (United States)

    Kaneko, Junichi; Sugawara, Yasuhiko; Matsui, Yuichi; Sakata, Hiroshi; Kokudo, Norihiro

    2009-01-01

    Hepatic artery and portal vein thrombosis are devastating complications of partial liver transplantation. Early detection of inflow complications is important, as re-reconstruction can salvage the graft. Near-infrared spectroscopy or laser Doppler flowmetry can be used to detect tissue oxygenation or microcirculation on the liver surface. The aim of this study was to examine which of these two methods better detects changes in hepatic inflow. Sangen-strain pigs (n = 5) were used. The tips of the near-infrared spectroscopy and laser Doppler flowmetry probes were placed separately on the surface of the right liver. Inflow to the liver was controlled during the following seven conditions: control (not clamped), half- and totally clamped portal vein, half- and totally clamped hepatic artery, and half- and totally clamped portal vein and artery. Tissue blood flow was calculated using laser Doppler flowmetry. Oxyhemoglobin, deoxyhemoglobin, and the tissue oxygenation index were measured and calculated using a near-infrared spectroscopy system. The tissue blood flow and oxygenation index could not be used to differentiate between the half-clamped portal vein, half-clamped hepatic artery, and totally clamped portal vein conditions. The oxyhemoglobin minus deoxyhemoglobin value was significantly decreased after half or total clamping of the portal vein or hepatic artery (p <. 001 for each condition). The findings of the present study indicate that near-infrared spectroscopy was more sensitive than Doppler flowmetry for detecting changes in hepatic tissue inflow from the liver surface.

  18. Damage Identification by Using a Self-Synchronizing Multipoint Laser Doppler Vibrometer

    Directory of Open Access Journals (Sweden)

    Chong Yang

    2015-01-01

    Full Text Available The vibration-based damage identification method extracts the damage location and severity information from the change of modal properties, such as natural frequency and mode shape. Its performance and accuracy depends on the measurement precision. Laser Doppler vibrometer (LDV provides a noncontact vibration measurement of high quality, but usually it can only do sampling on a single point. Scanning LDV is normally used to obtain the mode shape with a longer scanning time. In this paper, a damage detection technique is proposed using a self-synchronizing multipoint LDV. Multiple laser beams with various frequency shifts are projected on different points of the object, reflected and interfered with a common reference beam. The interference signal containing synchronized temporal vibration information of multiple spatial points is captured by a single photodetector and can be retrieved in a very short period. Experiments are conducted to measure the natural frequencies and mode shapes of pre- and postcrack cantilever beams. Mode shape curvature is calculated by numerical interpolation and windowed Fourier analysis. The results show that the artificial crack can be identified precisely from the change of natural frequencies and the difference of mode shape curvature squares.

  19. Determination of in vitro simulated blood cell velocity by laser-Doppler with state space methods.

    Science.gov (United States)

    Ledbetter-Nelepovitz, C C; Rao, B D; Fronek, A

    1991-03-01

    In this paper a signal processing method based on an important tool of numerical analysis, the singular value decomposition (SVD), is used. This method is applied to the unprocessed output of a Laser-Doppler fluxmeter to obtain parameters that are more sensitive to blood velocity than to hematocrit. The SVD-based method utilizes the exponential shape of the frequency spectrum of the laser light scattered from the moving red blood cells and demonstrates an inverse relationship between the damping constant beta associated with the exponential shape and the blood velocity. This method was applied to samples of rat blood of several known hematocrit values that were rotated at different velocities on a turntable. The method extracted one dominant singular value from the spectra, indicating that the spectra can be modeled as a single exponential dominated by scatterings with a single moving red blood cell. A 68% change in inverse velocity resulted in a 50% change in the damping constant (hematocrit 29.5% vol). On the other hand, a 37% change in hematocrit resulted in a far smaller change in the damping constant beta of only 17%. Analysis of the extracted parameters shows that the damping constants are far more influenced by blood velocity than by blood hematocrit.

  20. Photo-vibrational spectroscopy of solid and liquid chemicals using laser Doppler vibrometer.

    Science.gov (United States)

    Hu, Qi; Lim, Jacob Song Kiat; Liu, Huan; Fu, Yu

    2016-08-22

    Photoacoustic/photothermal spectroscopy is an established technique for trace detection of chemicals and explosives. However, prior sample preparation is required and the analysis is conducted in a sealed space with a high-sensitivity microphone or a piezo sensor coupled with a lock-in amplifier, limiting the technique to applications in a laboratory environment. Due to the aforementioned requirements, traditionally this technique may not be suitable for defense and security applications where the detection of explosives or hazardous chemicals is required in an open environment at a safe standoff distance. In this study, chemicals in various forms (membrane, powder and liquid) were excited by an intensity-modulated quantum cascade laser (QCL), while a laser Doppler vibrometer (LDV) based on the Mach-Zehnder interferometer was applied to detect the vibration signal resulting from the photocoustic/photothermal effect. The photo-vibrational spectrum obtained by scanning the QCL's wavelength in MIR range, coincides well with the corresponding spectrum obtained using typical FTIR equipment. The experiment demonstrated that the LDV is a capable sensor for applications in photoacoustic/photothermal spectroscopy, with potential to enable the detection of chemicals in open environment at safe standoff distance.

  1. Non-contact measurement of facial surface vibration patterns during singing by scanning laser Doppler vibrometer.

    Science.gov (United States)

    Kitamura, Tatsuya; Ohtani, Keisuke

    2015-01-01

    This paper presents a method of measuring the vibration patterns on facial surfaces by using a scanning laser Doppler vibrometer (LDV). The surfaces of the face, neck, and body vibrate during phonation and, according to Titze (2001), these vibrations occur when aerodynamic energy is efficiently converted into acoustic energy at the glottis. A vocalist's vibration velocity patterns may therefore indicate his or her phonatory status or singing skills. LDVs enable laser-based non-contact measurement of the vibration velocity and displacement of a certain point on a vibrating object, and scanning LDVs permit multipoint measurements. The benefits of scanning LDVs originate from the facts that they do not affect the vibrations of measured objects and that they can rapidly measure the vibration patterns across planes. A case study is presented herein to demonstrate the method of measuring vibration velocity patterns with a scanning LDV. The objective of the experiment was to measure the vibration velocity differences between the modal and falsetto registers while three professional soprano singers sang sustained vowels at four pitch frequencies. The results suggest that there is a possibility that pitch frequency are correlated with vibration velocity. However, further investigations are necessary to clarify the relationships between vibration velocity patterns and phonation status and singing skills.

  2. Characterization and demonstration of a 12-channel Laser-Doppler vibrometer

    Science.gov (United States)

    Haist, T.; Lingel, C.; Osten, W.; Bendel, K.; Giesen, M.; Gartner, M.; Rembe, C.

    2013-04-01

    Scanning laser-Doppler vibrometry is the standard optical, non-contact technology for vibration measurement applications in all areas of mechanical engineering. The vibration signals are measured from the different measurement points at different time points. This requires synchronization and the technology is limited to repeatable or periodic events. We have explored a new solution for the optical setup of the sensing system of a multi-channel vibrometer that we present in this paper. Our optical system is a 12-channel vibrometer and consists of a 12-channel interferometer unit which is connected with 12 optical fibers to a sensor head with 12 fiber-coupled objective lenses. Every objective lens can be focused manually and is placed in a sphere which can be tilted and fixed by a blocking screw. Thus it is possible to adjust a user defined measurement grid by hand. The user can define the geometry of the measurement grid in a camera image displayed in the software by just clicking on the laser foci. We use synchronous analog-digital conversion for the 12 heterodyne detector signals and a digital 12-channel-demodulator which is connected via USB to a computer. We can realize high deflection angles, good sensitivity, proper resolution, sufficient vibration bandwidth, and high maximum vibration amplitudes. In this paper, we demonstrate the optical and electrical setup of the manually adjustable 12-channel vibrometer, we present the experimentally evaluated performance of our device, and we present first measurements from real automotive applications.

  3. Absorption measurement of acoustic materials using a scanning laser Doppler vibrometer

    Science.gov (United States)

    Vanlanduit, Steve; Vanherzeele, Joris; Guillaume, Patrick; de Sitter, Gert

    2005-03-01

    In this article a method is proposed to estimate the normal incidence reflection ratio and absorption coefficient of acoustical materials using measurements in a transparent tube excited with a loudspeaker and terminated with the material under investigation. The waveforms are measured at different locations in the tube using a scanning laser Doppler vibrometer. Because the measurement probe (i.e., the laser beam) does not interfere with the wave in the tube, narrow tubes can be used. This means that-in contrast to the standardized wide tube tests using microphones-the proposed experiment could be used for high frequencies (in the paper an 8 mm tube was used, resulting in a 25 kHz upper frequency limit). It is shown based on theoretically known scenarios (i.e., an open tube and a rigid termination) that the absorption coefficient can be obtained with an error of about three percent. In addition, the absorption coefficient of two commonly used absorption materials-glass fiber wool and carpet-were determined and found to be in good agreement with material databases. .

  4. Vibration Mode Observation of Piezoelectric Disk-type Resonator by High Frequency Laser Doppler Vibrometer

    Science.gov (United States)

    Matsumura, Takeshi; Esashi, Masayoshi; Harada, Hiroshi; Tanaka, Shuji

    For future mobile phones based on cognitive radio technology, a compact multi-band RF front-end architecture is strongly required and an integrated multi-band RF filter bank is a key component in it. Contour-mode resonators are receiving increased attention for a multi-band filter solution, because its resonant frequency is mainly determined by its size and shape, which are defined by lithography. However, spurious responses including flexural vibration are also excited due to its thin structure. To improve resonator performance and suppress spurious modes, visual observation with a laser probe system is very effective. In this paper, we have prototyped a mechanically-coupled disk-array filter, which consists of a Si disk and 2 disk-type resonators of higher-order wine-glass mode, and observed its vibration modes using a high-frequency laser-Doppler vibrometer (UHF-120, Polytec, Inc.). As a result, it was confirmed that higher order wine-glass mode vibration included a compound displacement, and that its out-of-plane vibration amplitude was much smaller than other flexural spurious modes. The observed vibration modes were compared with FEM (Finite Element Method) simulation results. In addition, it was also confirmed that the fabrication error, e.g. miss-alignment, induced asymmetric vibration.

  5. Applications of spectral analysis and filter design in laser frequency locking for Na Doppler lidars

    Science.gov (United States)

    Smith, John A.; Chu, Xinzhao; Huang, Wentao; Tan, Bo

    2009-10-01

    A dye ring laser is stabilized to a D2a Doppler-free feature of sodium vapor using a LabVIEW®-based, phase-sensitive servo. Locking precision and stability, at better than +/-1 MHz, are suitable for Na lidar applications. This performance was achieved with improved digital filtering and new approaches to the problem. The inverse (type II) Chebyshev discrete filter employed demonstrates superior filtering and computational efficiency plus improved flexibility. New approaches include the determination of optimum modulation frequency, laser-tuning sensitivity, and bandwidth requirements via spectral analyses of the noise spectrum, derivative scan, and modulated spectrum. This practice guides a user in selecting the system operation parameters and negotiating the trade-offs involved when expanding the filter's passband. Allan deviation plots provide a quantitative description of the short- and long-term frequency excursions. A comparison of Allan deviation plots before and after locking shows a substantial improvement in stability throughout time scales from 0.10 to 10 s.

  6. A simulation environment for assisting system design of coherent laser doppler wind sensor for active wind turbine pitch control

    Science.gov (United States)

    Shinohara, Leilei; Pham Tran, Tuan Anh; Beuth, Thorsten; Umesh Babu, Harsha; Heussner, Nico; Bogatscher, Siegwart; Danilova, Svetlana; Stork, Wilhelm

    2013-05-01

    In order to assist a system design of laser coherent Doppler wind sensor for active pitch control of wind turbine systems (WTS), we developed a numerical simulation environment for modeling and simulation of the sensor system. In this paper we present this simulation concept. In previous works, we have shown the general idea and the possibility of using a low cost coherent laser Doppler wind sensing system for an active pitch control of WTS in order to achieve a reduced mechanical stress, increase the WTS lifetime and therefore reduce the electricity price from wind energy. Such a system is based on a 1.55μm Continuous-Wave (CW) laser plus an erbium-doped fiber amplifier (EDFA) with an output power of 1W. Within this system, an optical coherent detection method is chosen for the Doppler frequency measurement in megahertz range. A comparatively low cost short coherent length laser with a fiber delay line is used for achieving a multiple range measurement. In this paper, we show the current results on the improvement of our simulation by applying a Monte Carlo random generation method for positioning the random particles in atmosphere and extend the simulation to the entire beam penetrated space by introducing a cylindrical co-ordinate concept and meshing the entire volume into small elements in order to achieve a faster calculation and gain more realistic simulation result. In addition, by applying different atmospheric parameters, such as particle sizes and distributions, we can simulate different weather and wind situations.

  7. Application of a laser Doppler vibrometer for air-water to subsurface signature detection

    Science.gov (United States)

    Land, Phillip; Roeder, James; Robinson, Dennis; Majumdar, Arun

    2015-05-01

    There is much interest in detecting a target and optical communications from an airborne platform to a platform submerged under water. Accurate detection and communications between underwater and aerial platforms would increase the capabilities of surface, subsurface, and air, manned and unmanned vehicles engaged in oversea and undersea activities. The technique introduced in this paper involves a Laser Doppler Vibrometer (LDV) for acousto-optic sensing for detecting acoustic information propagated towards the water surface from a submerged platform inside a 12 gallon water tank. The LDV probes and penetrates the water surface from an aerial platform to detect air-water surface interface vibrations caused by an amplifier to a speaker generating a signal generated from underneath the water surface (varied water depth from 1" to 8"), ranging between 50Hz to 5kHz. As a comparison tool, a hydrophone was used simultaneously inside the water tank for recording the acoustic signature of the signal generated between 50Hz to 5kHz. For a signal generated by a submerged platform, the LDV can detect the signal. The LDV detects the signal via surface perturbations caused by the impinging acoustic pressure field; proving a technique of transmitting/sending information/messages from a submerged platform acoustically to the surface of the water and optically receiving the information/message using the LDV, via the Doppler Effect, allowing the LDV to become a high sensitivity optical-acoustic device. The technique developed has much potential usage in commercial oceanography applications. The present work is focused on the reception of acoustic information from an object located underwater.

  8. Two-component Duality and Strings

    CERN Document Server

    Freund, Peter G O

    2007-01-01

    A phenomenologically successful two-component hadronic duality picture led to Veneziano's amplitude, the fundamental first step to string theory. This picture is briefly recalled and its two components are identified as the open strings (mesons and baryons) and closed strings (Pomeron).

  9. Evaluation of algorithms for microperfusion assessment by fast simulations of laser Doppler power spectral density

    Science.gov (United States)

    Wojtkiewicz, S.; Liebert, A.; Rix, H.; Maniewski, R.

    2011-12-01

    In classical laser Doppler (LD) perfusion measurements, zeroth- and first-order moments of the power spectral density of the LD signal are utilized for the calculation of a signal corresponding to the concentration, speed and flow of red blood cells (RBCs). We have analysed the nonlinearities of the moments in relation to RBC speed distributions, parameters of filters utilized in LD instruments and the signal-to-noise ratio. We have developed a new method for fast simulation of the spectrum of the LD signal. The method is based on a superposition of analytically calculated Doppler shift probability distributions derived for the assumed light scattering phase function. We have validated the method by a comparison of the analytically calculated spectra with results of Monte Carlo (MC) simulations. For the semi-infinite, homogeneous medium and the single Doppler scattering regime, the analytical calculation describes LD spectra with the same accuracy as the MC simulation. The method allows for simulating the LD signal in time domain and furthermore analysing the index of perfusion for the assumed wavelength of the light, optical properties of the tissue and concentration of RBCs. Fast simulations of the LD signal in time domain and its frequency spectrum can be utilized in applications where knowledge of the LD photocurrent is required, e.g. in the development of detectors for tissue microperfusion monitoring or in measurements of the LD autocorrelation function for perfusion measurements. The presented fast method for LD spectra calculation can be used as a tool for evaluation of signal processing algorithms used in the LD method and/or for the development of new algorithms of the LD flowmetry and imaging. We analysed LD spectra obtained by analytical calculations using a classical algorithm applied in classical LD perfusion measurements. We observed nonlinearity of the first moment M1 for low and high speeds of particles (v 10 mm s-1). It was also noted that the

  10. Investigation of three-dimensional vibration measurement by a single scanning laser Doppler vibrometer

    Science.gov (United States)

    Chen, Da-Ming; Zhu, W. D.

    2017-01-01

    A scanning laser Doppler vibrometer (SLDV) has been widely used in non-contact vibration measurement. This paper presents a novel investigation of three-dimensional (3D) vibration measurement by a single SLDV sequentially placed at three different positions, where 3D vibration is defined as three vibration components along axes of a specified measurement coordinate system (MCS), which can give more precise knowledge of structural dynamic characteristics. A geometric model of the SLDV is proposed and a vibrometer coordinate system (VCS) based on the geometric model is defined and fixed on the SLDV. The pose of a SLDV with respect to a MCS is expressed in the form of a translation vector and a direction cosine matrix from the VCS to the MCS, which can be calculated by four or more target points with known coordinates in both the MCS and the VCS. An improved method based on the least squares method and singular value decomposition is proposed to obtain the pose of the SLDV. Compared with an inverse method, the proposed method can yield an orthogonal direction cosine matrix and be applicable to a two-dimensional structure. Effects of the number of target points on the accuracy and stability of the proposed method are investigated. With three direction cosine matrices of three different positions obtained by the proposed method, measured vibration velocities along laser line-of-sight directions can be transformed to vibration components along axes of the MCS. An experiment was conducted to measure 3D vibration of a target point on a beam under sinusoidal excitation by a single SLDV sequentially placed at three different positions. Vibration components along axes of the MCS obtained by the single SLDV were in good agreement with those from a commercial Polytec 3D scanning laser vibrometer PSV-500-3D.

  11. [Meta-analysis on the diagnostic value of laser Doppler imaging for burn depth].

    Science.gov (United States)

    Huang, Y; Qiu, L; Mei, A L; Li, J X

    2017-05-20

    Objective: To evaluate the value of laser Doppler imaging (LDI) in diagnosing deep or superficial partial-thickness burn wound with meta-analysis. Methods: Databases including PubMed, Cochrane Library were searched using key words " burn, burns, burn depth, laser Doppler imaging, laser Doppler perfusion imaging, LDI, LDPI" , and Chinese Journals Full-text Database, Wanfang Database, VIP Database were searched using Chinese key words ",,,," to obtain the published trials of LDI in diagnosing deep or superficial partial-thickness burn wound from the establishment of each database to October 2015. The risk of bias and applicability concerns of the included studies were evaluated by Quality Assessment of Diagnostic Accuracy Studies-2. Data were processed with Meta-DiSc 1.4 statistical software. The heterogeneity among the included studies was evaluated. The pooled estimates of LDI in diagnosing deep or superficial partial-thickness burn wound in the included studies, including sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, as well as the area under the curve of summary receiver operating characteristic and index of Q(*) were calculated. The stability of results of the overall pooled estimates of the included studies was validated by sensitivity analysis. The sources of heterogeneity among the included studies were sought through subgroup analysis. The publication bias caused by the results of the included studies was evaluated by drawing the Deek's funnel plot. Results: A total of 5 articles conforming to the inclusion criteria, involving 138 patients and 179 burn wounds, were included. One of the included studies had low risk of bias, while the other 4 studies had high/unclear risk of bias. In applicability concern aspect, one of the included studies had high/unclear concerns regarding applicability, while the other 4 studies had low concerns regarding applicability. There was no heterogeneity caused by threshold

  12. Reproducibility of non-invasive assessment of skin endothelial function using laser Doppler flowmetry and laser speckle contrast imaging.

    Directory of Open Access Journals (Sweden)

    Cyril Puissant

    Full Text Available BACKGROUND: Endothelial dysfunction precedes atherosclerosis. Vasodilation induced by acetylcholine (ACh is a specific test of endothelial function. Reproducibility of laser techniques such as laser-Doppler-flowmetry (LDF and Laser-speckle-contrast-imaging (LSCI to detect ACh vasodilation is debated and results expressions lack standardization. We aimed to study at a 7-day interval (i the inter-subject reproducibility, (ii the intra-subjects reproducibility, and (iii the effect of the results expressions over variability. METHODS AND RESULTS: Using LDF and LSCI simultaneously, we performed two different ACh-iontophoresis protocols. The maximal ACh vasodilation (peak-ACh was expressed as absolute or normalized flow or conductance values. Inter-subject reproducibility was expressed as coefficient of variation (inter-CV,%. Intra-subject reproducibility was expressed as within subject coefficients of variation (intra-CV,%, and intra-class correlation coefficients (ICC. Fifteen healthy subjects were included. The inter-subject reproducibility of peak-ACh depended upon the expression of the results and ranged from 55% to 162% for LDF and from 17% to 83% for LSCI. The intra-subject reproducibility (intra-CV/ICC of peak-ACh was reduced when assessed with LSCI compared to LDF no matter how the results were expressed and whatever the protocol used. The highest intra-subject reproducibility was found using LSCI. It was 18.7%/0.87 for a single current stimulation (expressed as cutaneous vascular conductance and 11.4%/0.61 for multiple current stimulations (expressed as absolute value. CONCLUSION: ACh-iontophoresis coupled with LSCI is a promising test to assess endothelial function because it is reproducible, safe, and non-invasive. N°: NCT01664572.

  13. A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    DEFF Research Database (Denmark)

    Kastrup, J; Bülow, J; Lassen, N A

    1987-01-01

    level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and 133Xenon blood flow measurements were performed simultaneously on the sympathetically denervated...... forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The 133Xenon method recorded a 44% decrease in blood flow in innervated...... and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and 133Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes....

  14. Feasibility Study of Velocity and Temperature Measurements of an Arcjet Flow using Laser Resonance Doppler Velocimetric (LRDV) Technique

    Science.gov (United States)

    Rob, Mohammad A.

    1996-01-01

    Thermal Protection System (TPS) materials are used in space vehicles to shield from high heating environment encountered during their atmospheric reentry. Arcjet wind tunnels are used to simulate the flowfield encountered by the spacecrafts, and are used for testing TPS materials. How well these tests simulate the actual heating environment encountered by space vehicles depends on the characteristics of the simulated flow. The flow characterization requires the determination of temperature, concentration, and velocity of the various atomic and molecular species present in the flow. However, determining these parameters requires a complex set of both analytical and experimental procedures. The ability to properly simulate the flight environment is directly related to the accuracy with which these techniques can be used to define the arcjet Laser Resonance Doppler Velocimetric (LRDV) technique can be used to accurately determine the velocity and temperature of a gaseous species. In this technique, the medium is probed with a laser beam that is in resonance with an absorbing transition of the species. The absorption lineshape is Doppler-shifted due to the flow velocity of the species, and the frequency shift is detected as the variation in intensity of the fluorescence emitted by the species. Thus a measurement of the Doppler shift and the width of a spectral line can give both the temperature and the velocity of the flowfield. This summer, our project was to make a feasibility study to set up an experimental arrangement for the laser resonance Doppler velocimetric technique using a ring dye laser. Experiments required troubleshooting, cleaning, testing, and alignment of two lasers and several diagnostics instruments. All instruments and lasers necessary for the project worked well, but the output power of the broadband fundamental dye laser was limited to about 20 mW. This was quite low as compared to that necessary to obtain second harmonic oscillation at 327.49 nm

  15. Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter

    OpenAIRE

    Wataru Iwasaki; Hirofumi Nogami; Satoshi Takeuchi; Masutaka Furue; Eiji Higurashi; Renshi Sawada

    2015-01-01

    Wearable wireless physiological sensors are helpful for monitoring and maintaining human health. Blood flow contains abundant physiological information but it is hard to measure blood flow during exercise using conventional blood flowmeters because of their size, weight, and use of optic fibers. To resolve these disadvantages, we previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems technology. This micro blood flowmeter is wearable and cap...

  16. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    Science.gov (United States)

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M

    2015-11-01

    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation.

  17. Model-based review of Doppler global velocimetry techniques with laser frequency modulation

    Science.gov (United States)

    Fischer, Andreas

    2017-06-01

    Optical measurements of flow velocity fields are of crucial importance to understand the behavior of complex flow. One flow field measurement technique is Doppler global velocimetry (DGV). A large variety of different DGV approaches exist, e.g., applying different kinds of laser frequency modulation. In order to investigate the measurement capabilities especially of the newer DGV approaches with laser frequency modulation, a model-based review of all DGV measurement principles is performed. The DGV principles can be categorized by the respective number of required time steps. The systematic review of all DGV principle reveals drawbacks and benefits of the different measurement approaches with respect to the temporal resolution, the spatial resolution and the measurement range. Furthermore, the Cramér-Rao bound for photon shot is calculated and discussed, which represents a fundamental limit of the achievable measurement uncertainty. As a result, all DGV techniques provide similar minimal uncertainty limits. With Nphotons as the number of scattered photons, the minimal standard deviation of the flow velocity reads about 106 m / s /√{Nphotons } , which was calculated for a perpendicular arrangement of the illumination and observation direction and a laser wavelength of 895 nm. As a further result, the signal processing efficiencies are determined with a Monte-Carlo simulation. Except for the newest correlation-based DGV method, the signal processing algorithms are already optimal or near the optimum. Finally, the different DGV approaches are compared regarding errors due to temporal variations of the scattered light intensity and the flow velocity. The influence of a linear variation of the scattered light intensity can be reduced by maximizing the number of time steps, because this means to acquire more information for the correction of this systematic effect. However, more time steps can result in a flow velocity measurement with a lower temporal resolution

  18. Percutaneous penetration of methyl nicotinate from ointments using the laser Doppler technique: bioequivalence and enhancer effects.

    Science.gov (United States)

    Remane, Yvonne; Leopold, Claudia S; Maibach, Howard I

    2006-12-01

    Laser Doppler flowmetry (LDF) may be used to quantify erythema response as a result of an increased cutaneous microcirculation induced by methyl nicotinate (MN). Bioequivalence of a test and a standard preparation (vehicles: light mineral oil and medium chain triglycerides, respectively) was confirmed according to the pilot study of the FDA Guidance for Industry "Topical dermatologic corticosteroids: In Vivo bioequivalence" applying the staggered application and synchronized removal method for one defined concentration. Furthermore, the influence of penetration enhancers (5% w/w Dimethylsulfoxide (DMSO) and 10% w/w diethylene glycol monoethyl ether) on MN penetration was investigated. It was shown that DMSO and diethylene glycol monoethyl ether altered cutaneous microcirculation and thus MN penetration in comparison to the standard formulation. However, true penetration enhancement could only be proved with diethylene glycol monoethyl ether resulting from an improved drug solubility in the skin which was confirmed by attenuated total reflectance fourier transform infrared spectroscopy (ATR-FTIR). Increased MN penetration by DMSO was only caused by thermodynamic effects, i.e. a decreased drug solubility in the vehicle.

  19. Laser Doppler Flare Imaging and Quantitative Thermal Thresholds Testing Performance in Small and Mixed Fiber Neuropathies

    Science.gov (United States)

    Alabdali, Majed; Alsulaiman, Abdulla; Breiner, Ari; Barnett, Carolina; Katzberg, Hans D.; Lovblom, Leif E.; Perkins, Bruce A.; Bril, Vera

    2016-01-01

    Introduction Small fiber neuropathy might be a part of typical mixed small and large fiber neuropathy, or a distinct entity, affecting exclusively small nerve fibers. Objectives Explore the utility of small nerve fiber testing in patients with clinical presentation suggesting small fiber neuropathy, with and without evidence for concomitant large fiber neuropathy. Methods Patients attending the neuromuscular clinic from 2012 to 2015 with a clinical presentation suggesting small nerve fiber impairment, who had Laser Doppler flare imaging (LDIFlare) and quantitative thermal testing (QTT) were evaluated for this study. Patients with clinical or electrophysiological evidence for concomitant large fiber neuropathy were not excluded. Results The sensitivities of LDIFlare, cooling and heat threshold testing were 64%, 36%, and 0% respectively for clinically highly suggestive small fiber neuropathy, 64%, 56%, and 19% respectively for mixed fiber neuropathy, and 86%, 79%, and 29% respectively for diabetic mixed fiber neuropathy. Discussion LDIFlare and cooling thresholds testing are non-invasive small nerve fiber testing modalities, with moderate performance in patients with small and mixed fiber neuropathy, and excellent performance in diabetic mixed fiber neuropathy. PMID:27824912

  20. Modal parameter determination of a lightweight aerospace panel using laser Doppler vibrometer measurements

    Science.gov (United States)

    de Sousa, Kleverson C.; Domingues, Allan C.; Pereira, Pedro P. de S.; Carneiro, Sergio H.; de Morais, Marcus V. G.; Fabro, Adriano T.

    2016-06-01

    The experimental determination of modal parameters, i.e. natural frequencies, mode shapes and damping ratio, are key in characterizing the dynamic behaviour of structures. Typically, such parameters are obtained from dynamic measurements using one or a set of accelerometers, for response measurements, along with force transducers from an impact hammer or an electrodynamic actuator, i.e. a shaker. However, lightweight structures, commonly applied in the aerospace industry, can be significantly affected by the added mass from accelerometers. Therefore, non-contact measurement techniques, like Laser Doppler Vibrometer (LDV), are a more suitable approach in determining the dynamic characteristics of such structures. In this article, the procedures and results of a modal test for a honeycomb sandwich panel for aerospace applications are presented and discussed. The main objectives of the test are the identification of natural frequencies and mode shapes in order to validate a numerical model, as well as the identification of the damping characteristics of the panel. A validated numerical model will be necessary for future detailed response analysis of the satellite, including vibroacoustic investigations to account for acoustic excitations encountered during launching. The numerical model using homogenised material properties is updated to fit the experimental results and very good agreement between experimental and numerically obtained natural frequencies and mode shapes.

  1. Laser Doppler Blood Flow Imaging Using a CMOS Imaging Sensor with On-Chip Signal Processing

    Directory of Open Access Journals (Sweden)

    Cally Gill

    2013-09-01

    Full Text Available The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.

  2. Laser doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing.

    Science.gov (United States)

    He, Diwei; Nguyen, Hoang C; Hayes-Gill, Barrie R; Zhu, Yiqun; Crowe, John A; Gill, Cally; Clough, Geraldine F; Morgan, Stephen P

    2013-09-18

    The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF) imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.

  3. A preliminary report on the use of laser-Doppler flowmetry during tethered spinal cord release.

    Science.gov (United States)

    Schneider, S J; Rosenthal, A D; Greenberg, B M; Danto, J

    1993-02-01

    Neurological deterioration in the tethered cord syndrome has been postulated to result from a compromise of blood flow in the distal spinal cord. In order to evaluate vascular perfusion in human subjects, a new technique of laser-Doppler flowmetry was used to monitor continuously the microcirculation of the distal spinal cord during surgery for tethered cord release in 10 children. For further comparison, five children undergoing selective dorsal rhizotomy were also monitored. In the tethered cord syndrome group, spinal cord blood flow before untethering was a mean of 12.6 ml/min per 100 g of tissue and increased in all cases after release to a mean of 29.4 ml/min per 100 g of tissue. All patients improved neurologically. The selective dorsal rhizotomy group had a preoperative mean spinal cord blood flow of 30.8 ml/min per 100 g of tissue, which was not altered by the operative procedure. Significant improvement occurs in distal spinal cord blood flow after tethered cord release, which may be representative of an important mechanism in the pathophysiology of the tethered cord syndrome.

  4. Quantum treatment of two-stage sub-Doppler laser cooling of magnesium atoms

    CERN Document Server

    Brazhnikov, D V; Taichenachev, A V; Yudin, V I; Bonert, A E; Il'enkov, R Ya; Goncharov, A N

    2015-01-01

    The problem of deep laser cooling of $^{24}$Mg atoms is theoretically studied. We propose two-stage sub-Doppler cooling strategy using electro-dipole transition $3^3P_2$$\\to$$3^3D_3$ ($\\lambda$=383.9 nm). The first stage implies exploiting magneto-optical trap with $\\sigma^+$ and $\\sigma^-$ light beams, while the second one uses a lin$\\perp$lin molasses. We focus on achieving large number of ultracold atoms (T$_{eff}$ < 10 $\\mu$K) in a cold atomic cloud. The calculations have been done out of many widely used approximations and based on quantum treatment with taking full account of recoil effect. Steady-state average kinetic energies and linear momentum distributions of cold atoms are analysed for various light-field intensities and frequency detunings. The results of conducted quantum analysis have revealed noticeable differences from results of semiclassical approach based on the Fokker-Planck equation. At certain conditions the second cooling stage can provide sufficiently lower kinetic energies of atom...

  5. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.

    Science.gov (United States)

    Abay, T Y; Kyriacou, P A

    2016-04-01

    Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.

  6. Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves

    Directory of Open Access Journals (Sweden)

    Ovandir Bazan

    2013-12-01

    Full Text Available INTRODUCTION: In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. OBJECTIVE: To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. METHODS: To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min. and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. RESULTS: It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. CONCLUSIONS: Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM is superior to the 21 AJ - 501 model (Master Series. Based on the results, future studies can choose to focus on specific regions of the these valves.

  7. Diagnostic accuracy of laser Doppler imaging in burn depth assessment: Systematic review and meta-analysis.

    Science.gov (United States)

    Shin, Jin Yong; Yi, Hyung Suk

    2016-11-01

    Accurate assessment of burn depth is important for determination of treatment modality. Laser Doppler imaging (LDI) is known to be an objective and effective measurement tool in burn depth assessment. Our study evaluated the diagnostic accuracy of LDI across enrolled studies and subgroups. A systematic literature review and meta-analysis were performed using MEDLINE, EMBASE, and Cochrane databases. Data from LDI cases were extracted from all primary studies and categorized into four cell values (true positives, false positives, true negatives, and false negatives). Subgroup analyses were performed according to perfusion units of LDI, clinical criteria of superficial and deep burns during the treatment period, and publication date of enrolled studies. The search strategy identified 321 publications. After screening, 10 articles were selected for review. The pooled sensitivity and specificity of LDI in all enrolled studies and subgroups were found to be similarly high. However, the sensitivity of LDI in our meta-analysis was not as high as that identified in previous studies. Although LDI in burn depth assessment was identified as an accurate measurement tool in this meta-analysis, careful clinical assessment should be performed along with LDI in patients with deep burns. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  8. Coupling airborne laser scanning and acoustic Doppler current profiler data to model stream rating curves

    Science.gov (United States)

    Lam, N.; Lyon, S. W.; Kean, J. W.

    2015-12-01

    The rating curve enables the translation of water depth into discharge through a reference cross section. Errors in estimating stream channel geometry can therefore result in increased discharge uncertainty. This study investigates coupling national-scale airborne laser scanning (ALS) and acoustic Doppler current profiler (ADCP) bathymetric survey data for generating stream rating curves. Specifically, stream channel geometries were generated from coupled ALS and ADCP scanning data collected for a well-monitored site located in northern Sweden. These data were used to define the hydraulic geometry required by a physically-based 1-D hydraulic model. The results of our study demonstrate that the effects of potential scanning data errors on the model generated rating curve were less than the uncertainties due to stream gauging measurements and empirical rating curve fitting. Further analysis of the ALS data showed that an overestimation of the streambank elevation (the main scanning data error) was primarily due to vegetation that could be adjusted for through a root-mean-square-error bias correction. We consider these findings encouraging as hydrometric agencies can potentially leverage national-scale ALS and ADCP instrumentation to reduce the cost and effort required for maintaining and establish rating curves at gauging stations.

  9. FUNCTIONAL STUDIES ON BLOOD MICROCIRCULATION SYSTEM WITH LASER DOPPLER FLOWMETRY IN CLINICAL MEDICINE: PROBLEMS AND PROSPECTS

    Directory of Open Access Journals (Sweden)

    D. G. Lapitan

    2016-01-01

    Full Text Available The paper presents a  review of the research update on the blood microcirculation system assessed with laser Doppler flowmetry (LDF. Specific procedures for measurement of the microcirculation index by LDF and individual variability of microcirculation parameters during their real time assessment in vivo are discussed. In physiological conditions, a relative deviation of the results of measurements by LDF is within the range±35% and above from the mean value of the microcirculation index. This imposes certain limitations on the interpretation of the diagnostic results in terms of the “normal or pathologic”. Specifics of performance of functional stress tests on the microcirculation system are reviewed. Diagnostic criteria based on functional stress testing of the microcirculation system, which can be implemented with methodologically strict normatives and regulations, for examples, those for the occlusion test, are more reliable from metrologic perspective and significant compared to the results obtained without stress testing. Problems of implementation of the functional tests into clinical practice are discussed. It was shown that they may have a potentially wide spectrum of clinical indications, from functional diagnostics and early detection of microcirculatory abnormalities in diabetes mellitus, arterial hypertension and other diseases associated with microcirculatory disorders, to the physical rationale of exposure parameters, as well as objectification of efficiency of medical procedures aimed to stimulation of the microcirculatory functions in a patient's tissues and organs.

  10. Laser Doppler Blood Flow Imaging Using a CMOS Imaging Sensor with On-Chip Signal Processing

    Science.gov (United States)

    He, Diwei; Nguyen, Hoang C.; Hayes-Gill, Barrie R.; Zhu, Yiqun; Crowe, John A.; Gill, Cally; Clough, Geraldine F.; Morgan, Stephen P.

    2013-01-01

    The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF) imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue. PMID:24051525

  11. MEMS characterization using new hybrid laser Doppler vibrometer/strobe video system

    Science.gov (United States)

    Lawrence, Eric M.; Rembe, Christian

    2004-01-01

    Laser Doppler Vibrometry (LDV) is a widely accepted tool for dynamic characterization of MEMS. Using automated scan capability, the Polytec system can measure structural resonance and display out-of-plane deflection shapes with amplitudes down to the picometer level and frequencies to 30 MHz. By adding stroboscopic video microscopy for in-plane motion analysis, our combined Micro Motion Analysis (MMA) system is capable of three-dimensional dynamic characterization. The MMA system opens up new possibilities to measure in-plane actuators previously difficult or impossible for LDV measurements. To exemplify the use of this technology, we present characterization measurements on MEMS devices fabricated by Sandia National Labs SUMMiT V process. Multi-axis measurements reveal the complex motions exhibited by an electrostatic comb drive driven at resonance. Also, ultra-high resolution velocity measurements are made on passive cantilever structures oscillating under thermal excitation. Picometer resolution makes possible detection of these purely mechanical resonances. Both comb drive and cantilever data are used to determine mechanical properties important to evaluate the reliability of fabrication processes. This study demonstrates the unique performance of our hybrid LDV / strobe video measurement system for quick, accurate, high-resolution dynamic response measurements.

  12. In-field use of laser Doppler vibrometer on a wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Rumsey, M.; Hurtado, J.; Hansche, B. [and others

    1998-12-31

    One of our primary goals was to determine how well a laser Doppler vibrometer (LDV) could measure the structural dynamic response of a wind turbine that was parked in the field. We performed a series of preliminary tests in the lab to determine the basic limitations of the LDV for this application. We then instrumented an installed parked horizontal axis wind turbine with accelerometers to determine the natural frequencies, damping, and mode shapes of the wind turbine and rotor as a baseline for the LDV and our other tests. We also wanted to determine if LDV modal information could be obtained from a naturally (wind) excited wind turbine. We compared concurrently obtained accelerometer and LDV data in an attempt to assess the quality of the LDV data. Our test results indicate the LDV can be successfully used in the field environment of an installed wind turbine, but with a few restrictions. We were successful in obtaining modal information from a naturally (wind) excited wind turbine in the field, but the data analysis requires a large number of averaged data sets to obtain reasonable results. An ultimate goal of this continuing project is to develop a technique that will monitor the health of a structure, detect damage, and hopefully predict an impending component failure.

  13. Assessment of coating layers on the accuracy of displacement measurement in laser Doppler vibrometry

    Science.gov (United States)

    Hasanian, Mostafa; Lissenden, Cliff J.

    2017-02-01

    The Laser Doppler Vibrometer (LDV) is known to be a useful tool for measuring vibration and wave propagation for non-destructive testing (NDT). Although LDV systems have many advantages, most notably that they provide non-contact measurements, they often require surface enhancement such as reflective tape to improve the signal-to-noise ratio. While accurate for low frequencies, measured displacements from tape can be significantly different from the displacement of the substrate once the frequency exceeds a threshold value. In this study, different tapes are mounted on the surface of an aluminum block, and out-of-plane displacements are recorded for frequencies from 1 to 5 MHz. In addition, dynamic finite element modeling is conducted, where the effect of reflective tapes on measured displacements on the surface of the tape is evaluated. Results of the finite element simulations reveal that the effective stiffness and mass of the tape can contribute significantly to errors in data acquisition during experiments. As evident in the results, the discrepancy between the measured displacements at the top and the bottom of the tape is considerable at some frequencies. The wave propagation simulation also provides improved understanding of the experimental results.

  14. Laser Doppler anemometer measurements of pulsatile flow in a model carotid bifurcation.

    Science.gov (United States)

    Ku, D N; Giddens, D P

    1987-01-01

    Hemodynamics at the human carotid bifurcation is important to the understanding of atherosclerotic plaque initiation and progression as well as to the diagnosis of clinically important disease. Laser Doppler anemometry was performed in a large scale model of an average human carotid. Pulsatile waveforms and physiologic flow divisions were incorporated. Disturbance levels and shear stresses were computed from ensemble averages of the velocity waveform measurements. Flow in the common carotid was laminar and symmetric. Flow patterns in the sinus, however, were complex and varied considerably during the cycle. Strong helical patterns and outer wall flow separation waxed and waned during each systole. The changing flow patterns resulted in an oscillatory shear stress at the outer wall ranging from -13 to 9 dyn cm-2 during systole with a time-averaged mean of only -0.5 dyn cm-2. This contrasts markedly with an inner wall shear stress range of 17-50, (mean 26) dyn cm-2. The region of transient separation was confined to the carotid sinus outer wall with no reverse velocities detected in the distal internal carotid. Notable disturbance velocities were also time-dependent, occurring only during the deceleration phase of systole and the beginning of diastole. The present pulsatile flow studies have aided in identifying hemodynamic conditions which correlate with early intimal thickening and predict the physiologic level of flow disturbances in the bulb of undiseased internal carotid arteries.

  15. Fringe mode transmittance laser Doppler microscope anemometer: its adaptation for measurement in the microcirculation.

    Science.gov (United States)

    Einav, S; Berman, H J

    1988-10-01

    Blood flow analysis in the microcirculation requires accurate measurement of velocity, volume flow and shear-rate versus shear-stress relationships. The resolution of most anemometers is too limited to obtain useful measurements, especially near the blood vessel wall and at branches and bifurcations. To make such measurements possible with a noninvasive, high resolution, accurate technique, we have developed a fringe mode, transmittance laser Doppler microscope anemometer (LDMA). This system has an intrinsically high spatial resolution (10 x 12 microns), and does not require a high concentration (10(6)/cm3) of scatters or red blood cells (RBC) as in our application. Preliminary measurements of water flow in a rectangular channel were conducted to ascertain the reliability and accuracy of velocity measurements using the LDMA. Velocity profiles were then measured by the LDMA system in arterioles 38-135 microns in diameter, in the transparent, everted cheek pouch of the anaesthetized hamster. The extremely high resolution of the optical system, and the ultra-fine traversing mechanism of the microscope stage, made velocity readings larger than 0.02 mm/s with accuracy and reproducibility better than 1%, possible near the wall to within 7-10 microns.

  16. Multifractal spectra of laser Doppler flowmetry signals in healthy and sleep apnea syndrome subjects

    Science.gov (United States)

    Buard, Benjamin; Trzepizur, Wojciech; Mahe, Guillaume; Chapeau-Blondeau, François; Rousseau, David; Gagnadoux, Frédéric; Abraham, Pierre; Humeau, Anne

    2009-07-01

    Laser Doppler flowmetry (LDF) signals give a peripheral view of the cardiovascular system. To better understand the possible modifications brought by sleep apnea syndrome (SAS) in LDF signals, we herein propose to analyze the complexity of such signals in obstructive SAS subjects, and to compare the results with those obtained in healthy subjects. SAS is a pathology that leads to a drop in the parasympathetic tone associated with an increase in the sympathetic tone in awakens SAS patients. Nine men with obstructive SAS and nine healthy men participated awaken in our study and LDF signals were recorded in the forearm. In our work, complexity of LDF signals is analyzed through the computation and analysis of their multifractal spectra. The multifractal spectra are estimated by first estimating the discrete partition function of the signals, then by determining their Renyi exponents with a linear regression, and finally by computing their Legendre transform. The results show that, at rest, obstructive SAS has no or little impact on the multifractal spectra of LDF signals recorded in the forearm. This study shows that the physiological modifications brought by obstructive SAS do not modify the complexity of LDF signals when recorded in the forearm.

  17. Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry

    Science.gov (United States)

    Fredriksson, Ingemar; Burdakov, Oleg; Larsson, Marcus; Strömberg, Tomas

    2013-12-01

    The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion are estimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry (LDF). The DRS spectra (450 to 850 nm) are assessed at two source-detector separations (0.4 and 1.2 mm), allowing for a relative calibration routine, whereas LDF spectra are assessed at 1.2 mm in the same fiber-optic probe. Data are analyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayered tissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information. Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluate the method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1 percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and 23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations are presented. The method offers several advantages such as simultaneous quantification of RBC tissue fraction and oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speed resolved, absolute (% RBC×mm/s), and more accurate due to the combination with DRS.

  18. Microcirculation assessment using an individualized model for diffuse reflectance spectroscopy and conventional laser Doppler flowmetry

    Science.gov (United States)

    Strömberg, Tomas; Karlsson, Hanna; Fredriksson, Ingemar; Nyström, Fredrik H.; Larsson, Marcus

    2014-05-01

    Microvascular assessment would benefit from co-registration of blood flow and hemoglobin oxygenation dynamics during stimulus response tests. We used a fiber-optic probe for simultaneous recording of white light diffuse reflectance (DRS; 475-850 nm) and laser Doppler flowmetry (LDF; 780 nm) spectra at two source-detector distances (0.4 and 1.2 mm). An inverse Monte Carlo algorithm, based on a multiparameter three-layer adaptive skin model, was used for analyzing DRS data. LDF spectra were conventionally processed for perfusion. The system was evaluated on volar forearm recordings of 33 healthy subjects during a 5-min systolic occlusion protocol. The calibration scheme and the optimal adaptive skin model fitted DRS spectra at both distances within 10%. During occlusion, perfusion decreased within 5 s while oxygenation decreased slowly (mean time constant 61 s dissociation of oxygen from hemoglobin). After occlusion release, perfusion and oxygenation increased within 3 s (inflow of oxygenized blood). The increased perfusion was due to increased blood tissue fraction and speed. The supranormal hemoglobin oxygenation indicates a blood flow in excess of metabolic demands. In conclusion, by integrating DRS and LDF in a fiber-optic probe, a powerful tool for assessment of blood flow and oxygenation in the same microvascular bed has been presented.

  19. Exploiting Continuous Scanning Laser Doppler Vibrometry in timing belt dynamic characterisation

    Science.gov (United States)

    Chiariotti, P.; Martarelli, M.; Castellini, P.

    2017-03-01

    Dynamic behaviour of timing belts has always interested the engineering community over the years. Nowadays, there are several numerical methods to predict the dynamics of these systems. However, the tuning of such models by experimental approaches still represents an issue: an accurate characterisation does require a measurement in operating conditions since the belt mounting condition might severely affect its dynamic behaviour. Moreover, since the belt is constantly moving during running conditions, non-contact measurement methods are needed. Laser Doppler Vibrometry (LDV) and imaging techniques do represent valid candidates for this purpose. This paper aims at describing the use of Continuous Scanning LDV (CSLDV) as a tool for the dynamic characterisation of timing belts in IC (Internal Combustion) engines (cylinder head). The high-spatial resolution data that can be collected in short testing time makes CSLDV highly suitable for such application. The measurement on a moving surface, however, represents a challenge for CSLDV. The paper discusses how the belt in-plane speed influences CSLDV signal and how an order-based multi-harmonic excitation might affect the recovery of Operational Deflection Shapes in a CSLDV test. A comparison with a standard Discrete Scanning LDV measurement is also given in order to show that a CSLDV test, if well designed, can indeed provide the same amount of information in a drastically reduced amount of time.

  20. Reproducibility of transcutaneous oximetry and laser Doppler flowmetry in facial skin and gingival tissue.

    Science.gov (United States)

    Svalestad, J; Hellem, S; Vaagbø, G; Irgens, A; Thorsen, E

    2010-01-01

    Laser Doppler flowmetry (LDF) and transcutaneous oximetry (TcPO(2)) are non-invasive techniques, widely used in the clinical setting, for assessing microvascular blood flow and tissue oxygen tension, e.g. recording vascular changes after radiotherapy and hyperbaric oxygen therapy. With standardized procedures and improved reproducibility, these methods might also be applicable in longitudinal studies. The aim of this study was to evaluate the reproducibility of facial skin and gingival LDF and facial skin TcPO(2). The subjects comprised ten healthy volunteers, 5 men, aged 31-68 years. Gingival perfusion was recorded with the LDF probe fixed to a custom made, tooth-supported acrylic splint. Skin perfusion was recorded on the cheek. TcPO(2) was recorded on the forehead and cheek and in the second intercostal space. The reproducibility of LDF measurements taken after vasodilation by heat provocation was greater than for basal flow in both facial skin and mandibular gingiva. Pronounced intraday variations were observed. Interweek reproducibility assessed by intraclass correlation coefficient ranged from 0.74 to 0.96 for LDF and from 0.44 to 0.75 for TcPO(2). The results confirm acceptable reproducibility of LDF and TcPO(2) in longitudinal studies in a vascular laboratory where subjects serve as their own controls. The use of thermoprobes is recommended. Repeat measurements should be taken at the same time of day.

  1. Eye-safe diode laser Doppler lidar with a MEMS beam-scanner.

    Science.gov (United States)

    Hu, Qi; Pedersen, Christian; Rodrigo, Peter John

    2016-02-08

    We present a novel Doppler lidar that employs a cw diode laser operating at 1.5 μm and a micro-electro-mechanical-system scanning mirror (MEMS-SM). In this work, two functionalities of the lidar system are demonstrated. Firstly, we describe the capability to effectively steer the lidar probe beam to multiple optical transceivers along separate lines-of-sight. The beam steering functionality is demonstrated using four lines-of-sight--each at an angle of 18° with respect to their symmetry axis. Secondly, we demonstrate the ability to spatially dither the beam focus to reduce the mean irradiance at the probing distance (R = 60 m) of each line-of-sight--elevant for meeting eye-safety requirements. The switching time of the MEMS-SM is measured to be in the order of a few milliseconds. Time-shared (0.25 s per line-of-sight) radial wind speed measurements at 50 Hz data rate are experimentally demonstrated. Spatial dithering of the beam focus is also implemented using a spiral scan trajectory resulting in a 16 dB reduction of beam focus mean irradiance.

  2. Application of a new laser Doppler imaging system in planning and monitoring of surgical flaps

    Science.gov (United States)

    Schlosser, Stefan; Wirth, Raphael; Plock, Jan A.; Serov, Alexandre; Banic, Andrej; Erni, Dominique

    2010-05-01

    There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9×9 cm with a resolution of 256×256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.

  3. Laser Doppler velocimeter measurements and laser sheet imaging in an annular combustor model. M.S. Thesis, Final Report

    Science.gov (United States)

    Dwenger, Richard Dale

    1995-01-01

    An experimental study was conducted in annular combustor model to provide a better understanding of the flowfield. Combustor model configurations consisting of primary jets only, annular jets only, and a combination of annular and primary jets were investigated. The purpose of this research was to provide a better understanding of combustor flows and to provide a data base for comparison with computational models. The first part of this research used a laser Doppler velocimeter to measure mean velocity and statistically calculate root-mean-square velocity in two coordinate directions. From this data, one Reynolds shear stress component and a two-dimensional turbulent kinetic energy term was determined. Major features of the flowfield included recirculating flow, primary and annular jet interaction, and high turbulence. The most pronounced result from this data was the effect the primary jets had on the flowfield. The primary jets were seen to reduce flow asymmetries, create larger recirculation zones, and higher turbulence levels. The second part of this research used a technique called marker nephelometry to provide mean concentration values in the combustor. Results showed the flow to be very turbulent and unsteady. All configurations investigated were highly sensitive to alignment of the primary and annular jets in the model and inlet conditions. Any imbalance between primary jets or misalignment of the annular jets caused severe flow asymmetries.

  4. Laser frequency stabilization and large detuning by Doppler-free dichroic lock technique: Application to atom cooling

    Indian Academy of Sciences (India)

    V B Tiwari; S R Mishra; H S Rawat; S Singh; S P Ram; S C Mehendale

    2005-09-01

    We present results of a study of frequency stabilization of a diode laser ( = 780 nm) using the Doppler-free dichroic lock (DFDL) technique and its use for laser cooling of atoms. Quantitative measurements of frequency stability were performed and the Allan variance was found to be 6.9 × 10−11 for an averaging time of 10 s. The frequency-stabilized diode laser was used to obtain the trapping beams for a magneto-optic trap (MOT) for Rb atoms. Using the DFDL technique, the laser frequency could be locked over a wide range and this enabled measurement of detuning dependence of the number and temperature of cold atoms using a relatively simple experimental set-up.

  5. Doppler-limited dye laser excitation spectroscopy of the DSO radical

    Science.gov (United States)

    Ohashi, Nobukimi; Kakimoto, Masao; Saito, Shuji; Hirota, Eizi

    1980-11-01

    The Ã2A'(003) ← X˜2A″(000) vibronic transition (16 370 to 16 425 cm -1) of the DSO radical in studied by Doppler-limited dye laser excitation spectroscopy. DSO is produced in a flow system by reacting the products of a microwave discharge in O 2 with D 2S. About 637 observed lines are assigned to 987 transitions of the 19 subbands: K' a ← K″ a = 6 ← 5, 5 ← 4, 4 ← 3, 3 ← 2, 2 ← 1, 1 ← 0, 0 ← 1, 1 ← 2, 2 ← 3, 3 ← 4, 0 ← 0, 1 ← 1, 2 ← 2, 3 ← 3, 4 ← 4, 3 ← 1, 2 ← 0, 0 ← 2, and 1 ← 3. They are analyzed to determine rotational constants, centrifugal distortion constants, and spin-rotation constants for both the ground and the excited electronic states. The band origin obtained is 16 413.874 (2.5σ = 0.002) cm -1. The rotational constants determined are combined with the previous result on HSO (M. Kakimoto et al., J. Mol. Spectrosc.80, 334-350 (1980)) to calculate the structural parameters for this radical in both the states: r( SO) = 1.494(5) Å, r( SH) = 1.389(5) Å, and ∠HSO = 106.6(5)° for the X˜2A″ state, and r( SO) = 1.661(10) Å, r( SH) = 1.342(8) Å, and ∠HSO = 95.7(21)° for the Ã2A'(003) state, where values in parentheses denote 2.5σ.

  6. Accuracy of early burn depth assessment by laser Doppler imaging on different days post burn.

    Science.gov (United States)

    Hoeksema, Henk; Van de Sijpe, Karlien; Tondu, Thiery; Hamdi, Moustapha; Van Landuyt, Koenraad; Blondeel, Phillip; Monstrey, Stan

    2009-02-01

    Accurate diagnosis of burn depth is essential in selecting the most appropriate treatment. Early assessment of burn depth by clinical means only has been shown to be inaccurate, resulting in unnecessary operations or delay of grafting procedures. Laser Doppler imaging (LDI) was reported as an objective technique to determine the depth of a burn wound, but the accuracy on very early days post burn has never been investigated yet. In 40 patients with intermediate depth burns, we prospectively evaluated and compared the accuracy of the LDI measurements with the clinical assessments on days 0, 1, 3, 5, 8. Clinical evaluation of the depth of the burn was performed by two observers blinded to the LDI images. Accuracies were assessed by comparison with outcome: healing times longer than 21 days were considered to be equivalent to a biopsy finding of a deep dermal wound. Obviously superficial and full thickness wounds were excluded. LDI flux level was used for LDI prediction of outcome: less than 220PU to predict non-healing at day 21. The accuracies of burn depth assessments on the day of burn and post burn days 0, 1, 3, 5 and 8 using LDI were 54%, 79.5%, 95%, 97% and 100% compared with clinical assessment accuracies of 40.6%, 61.5%, 52.5%, 71.4% and 100%, respectively. LDI accuracy was significantly higher than clinical accuracy on day 3 (pBurn depth conversion was also considered. This is the first study to quantify the advantage of LDI scanning over clinical assessments during these important early after burn days.

  7. Functionalization and characterization of persistent luminescence nanoparticles by dynamic light scattering, laser Doppler and capillary electrophoresis.

    Science.gov (United States)

    Ramírez-García, Gonzalo; d'Orlyé, Fanny; Gutiérrez-Granados, Silvia; Martínez-Alfaro, Minerva; Mignet, Nathalie; Richard, Cyrille; Varenne, Anne

    2015-12-01

    Zinc gallate nanoparticles doped with chromium (III) (ZnGa1.995O4:Cr0.005) are innovative persistent luminescence materials with particular optical properties allowing their use for in vivo imaging. They can be excited in the tissue transparency window by visible photons and emit light for hours after the end of the excitation. This allows to observe the probe without any time constraints and without autofluorescence signals produced by biological tissues. Modification of the surface of these nanoparticles is essential to be colloidally stable not only for cell targeting applications but also for proper distribution in living organisms. The use of different methods for controlling and characterizing the functionalization process is imperative to better understand the subsequent interactions with biological elements. This work explores for the first time the characterization and optimization of a classic functionalization sequence, starting with hydroxyl groups (ZGO-OH) at the nanoparticle surface, followed by an aminosilane-functionalization intermediate stage (ZGO-NH2) before PEGylation (ZGO-PEG). Dynamic light scattering and laser doppler electrophoresis were used in combination with capillary electrophoresis to characterize the nanoparticle functionalization processes and control their colloidal and chemical stability. The hydrodynamic diameter, zeta potential, electrophoretic mobility, stability over time and aggregation state of persistent luminescence nanoparticles under physiological-based solution conditions have been studied for each functional state. Additionally, a new protocol to improve ZGO-NH2 stability based on a thermal treatment to complete covalent binding of (3-aminopropyl) triethoxysilane onto the particle surface has been optimized. This thorough control increases our knowledge on these nanoparticles for subsequent toxicological studies and ultimately medical application.

  8. Vibration transmissibility on rifle shooter: A comparison between accelerometer and laser Doppler vibrometer data

    Science.gov (United States)

    Scalise, L.; Casacanditella, L.; Santolini, C.; Martarelli, M.; Tomasini, E. P.

    2014-05-01

    The transmission of mechanical vibrations from tools to human subjects is known to be potentially dangerous for the circulatory and neurological systems. It is also known that such damages are strictly depending on the intensity and the frequency range of the vibrational signals transferred to the different anatomical districts. In this paper, very high impulsive signals, generated during a shooting by a rifle, will be studied, being such signals characterised by a very high acceleration amplitude as well as high frequency range. In this paper, it will be presented an experimental setup aimed to collect experimental data relative to the transmission of the vibration signals from the rifle to the shoulder of subject during the shooting action. In particular the transmissibility of acceleration signals, as well as of the velocity signals, between the rifle stock and the subject's back shoulder will be measured using two piezoelectric accelerometers and a single point laser Doppler vibrometer (LDV). Tests have been carried out in a shooting lab where a professional shooter has conducted the experiments, using different experimental configurations: two different types of stocks and two kinds of bullets with different weights were considered. Two uniaxial accelerometers were fixed on the stock of the weapon and on the back of the shoulder of the shooter respectively. Vibration from the back shoulder was also measured by means of a LDV simultaneously. A comparison of the measured results will be presented and the pros and cons of the use of contact and non-contact transducers will be discussed taking into account the possible sources of the measurement uncertainty as unwanted sensor vibrations for the accelerometer.

  9. A laser-lock concept to reach cm/s-precision in Doppler experiments with Fabry-Perot wavelength calibrators

    CERN Document Server

    Reiners, A; Ulbrich, R G

    2014-01-01

    State-of-the-art Doppler experiments require wavelength calibration with precision at the cm/s level. A low-finesse Fabry-Perot interferometer (FPI) can provide a wavelength comb with a very large bandwidth as required for astronomical experiments, but unavoidable spectral drifts are difficult to control. Instead of actively controlling the FPI cavity, we propose to passively stabilize the interferometer and track the time-dependent cavity length drift externally. A dual-finesse cavity allows drift tracking during observation. The drift of the cavity length is monitored in the high-finesse range relative to an external standard: a single narrow transmission peak is locked to an external cavity diode laser and compared to an atomic frequency. Following standard locking schemes, tracking at sub-mm/s precision can be achieved. This is several orders of magnitude better than currently planned high-precision Doppler experiments. It allows freedom for relaxed designs rendering this approach particularly interesting...

  10. Inertial deposition effects: a study of aerosol mechanics in the trachea using laser Doppler velocimetry and fluorescent dye.

    Science.gov (United States)

    Corcoran, T E; Chigier, Norman

    2002-12-01

    This study characterizes the axial velocity and axial turbulence intensity patterns noted in the tracheal portion of a cadaver-based throat model at two different steady flow rates (18.1 and 41.1 LPM.) This characterization was performed using Phase Doppler Interferometry (Laser Doppler Velocimetry). Deposition, as assessed qualitatively using fluorescent dye, is related to the position of the laryngeal jet within the trachea. The position of the jet is dependent on the downstream conditions of the model. It is proposed therefore that lung/airway conditions may have important effects on aerosol deposition within the throat. There is no correspondence noted between regions of high axial turbulence intensity and deposition.

  11. Time domain algorithm for accelerated determination of the first order moment of photo current fluctuations in high speed laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Draijer, M.; Hondebrink, E.; van Leeuwen, T.; Steenbergen, W.

    2009-01-01

    Advances in optical array sensor technology allow for the real time acquisition of dynamic laser speckle patterns generated by tissue perfusion, which, in principle, allows for real time laser Doppler perfusion imaging (LDPI). Exploitation of these developments is enhanced with the introduction of f

  12. Inhibitors targeting two-component signal transduction.

    Science.gov (United States)

    Watanabe, Takafumi; Okada, Ario; Gotoh, Yasuhiro; Utsumi, Ryutaro

    2008-01-01

    A two-component signal transduction system (TCS) is an attractive target for antibacterial agents. In this chapter, we review the TCS inhibitors developed during the past decade and introduce novel drug discovery systems to isolate the inhibitors of the YycG/YycF system, an essential TCS for bacterial growth, in an effort to develop a new class of antibacterial agents.

  13. Utilization of laser Doppler flowmetry and tissue spectrophotometry for burn depth assessment using a miniature swine model.

    Science.gov (United States)

    Lotter, Oliver; Held, Manuel; Schiefer, Jennifer; Werner, Ole; Medved, Fabian; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Jaminet, Patrick; Rothenberger, Jens

    2015-01-01

    Currently, the diagnosis of burn depth is primarily based on a visual assessment and can be dependent on the surgeons' experience. The goal of this study was to determine the ability of laser Doppler flowmeter combined with a tissue spectrophotometer to discriminate burn depth in a miniature swine burn model. Burn injuries of varying depth, including superficial-partial, deep-partial, and full thickness, were created in seven Göttingen minipigs using an aluminium bar (100 °C), which was applied to the abdominal skin for periods of 1, 3, 6, 12, 30, and 60 seconds with gravity alone. The depth of injury was evaluated histologically using hematoxylin and eosin staining. All burns were assessed 3 hours after injury using a device that combines a laser light and a white light to determine blood flow, hemoglobin oxygenation, and relative amount of hemoglobin. The blood flow (41 vs. 124 arbitrary units [AU]) and relative amount of hemoglobin (32 vs. 52 AU) were significantly lower in full thickness compared with superficial-partial thickness burns. However, no significant differences in hemoglobin oxygenation were observed between these depths of burns (61 vs. 60%). These results show the ability of laser Doppler flowmeter and tissue spectrophotometer in combination to discriminate between various depths of injury in the minipig model, suggesting that this device may offer a valuable tool for burn depth assessment influencing burn management. © 2014 by the Wound Healing Society.

  14. Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

    Energy Technology Data Exchange (ETDEWEB)

    Weekes, B.; Ewins, D. [University of Bristol, Queen' s Building, University Walk, Bristol, BS8 1TR (United Kingdom); Acciavatti, F. [Universita' Politecnica Delle Marche, Via Brecce Bianche 12, 60131 Ancona (Italy)

    2014-05-27

    To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics.

  15. Monostatic coaxial 1.5 μm laser Doppler velocimeter using a scanning Fabry-Perot interferometer.

    Science.gov (United States)

    Rodrigo, Peter John; Pedersen, Christian

    2013-09-09

    We present a laser Doppler velocimeter (LDV) in monostatic coaxial arrangement consisting of off-the-shelf telecom-grade components: a single frequency laser (wavelength λ = 1.5 μm) and a high-finesse scanning Fabry-Perot interferometer (sFPI). In contrast to previous 1.5 μm LDV systems based on heterodyne detection, our sFPI-LDV has the advantages of having large remote sensing range not limited by laser coherence, high velocity dynamic range not limited by detector bandwidth and inherent sign discrimination of Doppler shift. The more optically efficient coaxial arrangement where transmitter and receiver optics share a common axis reduces the number of components and greatly simplifies the optical alignment. However, the sensitivity to unwanted backreflections is increased. To circumvent this problem, we employ a custom optical circulator design which compared to commercial fiber-optic circulator achieves ~40 dB reduction in strength of unwanted reflections (i.e. leakage) while maintaining high optical efficiency. Experiments with a solid target demonstrate the performance of the sFPI-LDV system with high sensitivity down to pW level at present update rates up to 10 Hz.

  16. Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

    Science.gov (United States)

    Weekes, B.; Ewins, D.; Acciavatti, F.

    2014-05-01

    To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics.

  17. Comparison between /sup 133/Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    Energy Technology Data Exchange (ETDEWEB)

    Kastrup, J.; Buelow, J.; Lassen, N.A.

    1987-10-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by /sup 133/Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vaso-constrictor reflex by lowering the area of investigation below heart level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and /sup 133/Xenon blood flow measurements were performed simultaneously on the sympathetically denervated forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The /sup 133/Xenon method recorded a 44% decrease in blood flow in innervated and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and /sup 133/Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes.

  18. Time of correlation of low-frequency fluctuations in the regional laser Doppler flow signal from human skin

    Science.gov (United States)

    Folgosi-Correa, M. S.; Nogueira, G. E. C.

    2012-06-01

    The laser Doppler flowmetry allows the non-invasive assessment of the skin perfusion in real-time, being an attractive technique to study the human microcirculation in clinical settings. Low-frequency oscillations in the laser Doppler blood flow signal from the skin have been related to the endothelial, endothelial-metabolic, neurogenic and myogenic mechanisms of microvascular flow control, in the range 0.005-0.0095 Hz, 0.0095-0.021 Hz, 0.021-0.052 Hz and 0.052- 0.145 Hz respectively. The mean Amplitude (A) of the periodic fluctuations in the laser Doppler blood flow signal, in each frequency range, derived from the respective wavelet-transformed coefficients, has been used to assess the function and dysfunctions of each mechanism of flow control. Known sources of flow signal variances include spatial and temporal variability, diminishing the discriminatory capability of the technique. Here a new time domain method of analysis is proposed, based on the Time of Correlation (TC) of flow fluctuations between two adjacent sites. Registers of blood flow from two adjacent regions, for skin temperature at 32 0C (basal) and thermally stimulated (42 0C) of volar forearms from 20 healthy volunteers were collected and analyzed. The results obtained revealed high time of correlation between two adjacent regions when thermally stimulated, for signals in the endothelial, endothelial-metabolic, neurogenic and myogenic frequency ranges. Experimental data also indicate lower variability for TC when compared to A, when thermally stimulated, suggesting a new promising parameter for assessment of the microvascular flow control.

  19. Repeatability of the evaluation of systemic microvascular endothelial function using laser doppler perfusion monitoring: clinical and statistical implications

    Directory of Open Access Journals (Sweden)

    Eduardo Tibiriçá

    2011-01-01

    Full Text Available OBJECTIVE: An awareness of the repeatability of biological measures is required to properly design and calculate sample sizes for longitudinal interventional studies. We investigated the day-to-day repeatability of measures of systemic microvascular reactivity using laser Doppler perfusion monitoring. METHODS: We performed laser Doppler perfusion monitoring in combination with skin iontophoresis using acetylcholine and sodium nitroprusside as well as post-occlusive reactive and thermal hyperemia twice within two weeks. The repeatability was assessed by calculating the within-subject standard deviations, limits of agreement, typical errors and intra-class correlation coefficients between days 1 and 2. The ratio of the within-subject standard deviation to the mean values obtained on days 1 and 2 (within-subject standard deviation/GM was used to determine the condition with the best repeatability. RESULTS: Twenty-four healthy subjects, aged 24.6 + 3.8 years, were recruited. The area under the curve of the vasodilatory response to post-occlusive reactivity showed marked variability (within-subject standard deviation/GM = 0.83, while the area under the curve for acetylcholine exhibited less variability (within-subject standard deviation/ GM = 0.52 and was comparable to the responses to sodium nitroprusside and thermal treatment (within-subject standard deviations/GM of 0.67 and 0.56, respectively. The area under the blood flow/time curve for vasodilation during acetylcholine administration required the smallest sample sizes, the area under the blood flow/time curve during post-occlusive reactivity required the largest sample sizes, and the area under the blood flow/time curves of vasodilation induced by sodium nitroprusside and thermal treatment required intermediate sizes. CONCLUSIONS: In view of the importance of random error related to the day-to-day repeatability of laser Doppler perfusion monitoring, we propose an original and robust statistical

  20. Effect of clenbuterol on cardiopulmonary parameters and intramuscular blood flow by laser Doppler flowmetry in anesthetized ponies

    Science.gov (United States)

    Lee, Yong H.; Clarke, Kathleen W.; Alibhai, Hatim I. K.

    1994-09-01

    The cardiopulmonary affects and the affects on muscular microperfusion of the beta adrenergic agonist, clenbuterol (0.8 mcg/kg intravenously), were investigated in dorsally recumbent anesthetized ponies. Muscle microcirculation was measured by laser Doppler flowmetry, utilizing fine optical fiber probes. Other measurements included heart rate, cardiac output, arterial blood pressure, and arterial blood gas tensions. Clenbuterol injection caused a regular, but transitory rise in muscle microcirculation, an increase in heart rate, and cardiac output and a decrease in mean arterial blood pressure. Clenbuterol did appear to prevent the continuing fall in arterial blood oxygen tensions seen in the treatment groups, but had only minimal affects in reversing the hypoxia already present.

  1. Evaluation of Influence of Acupuncture and Electro-Acupuncture for Blood Perfusion of Stomach by Laser Doppler Blood Perfusion Imaging

    OpenAIRE

    Zhang Dong; Li Shun-Yue; Wang Shu-You; Ma Hui-Min

    2011-01-01

    The objective of this study is to observe effects of acupuncture and electro-acupuncture (EA) on blood perfusion in the stomach, and probe into the application of laser Doppler blood perfusion imaging technique in the study of the effect of acupuncture and moxibustion on the entrails. In the acupuncture group of 20 rats, acupuncture was given at “Zusanli” (ST 36) and in EA group of 18 rats, EA was applied at “Zusanli” (ST 36), with 18 rats without acupuncture used as control group. Changes of...

  2. Applying Laser Doppler Anemometry inside a Taylor-Couette geometry - Using a ray-tracer to correct for curvature effects

    OpenAIRE

    Huisman, Sander G.; van Gils, Dennis P. M.; Sun, Chao

    2012-01-01

    In the present work it will be shown how the curvature of the outer cylinder affects Laser Doppler anemometry measurements inside a Taylor-Couette apparatus. The measurement position and the measured velocity are altered by curved surfaces. Conventional methods for curvature correction are not applicable to our setup, and it will be shown how a ray-tracer can be used to solve this complication. By using a ray-tracer the focal position can be calculated, and the velocity can be corrected. The ...

  3. Two-component Abelian sandpile models.

    Science.gov (United States)

    Alcaraz, F C; Pyatov, P; Rittenberg, V

    2009-04-01

    In one-component Abelian sandpile models, the toppling probabilities are independent quantities. This is not the case in multicomponent models. The condition of associativity of the underlying Abelian algebras imposes nonlinear relations among the toppling probabilities. These relations are derived for the case of two-component quadratic Abelian algebras. We show that Abelian sandpile models with two conservation laws have only trivial avalanches.

  4. Fibre Optic Laser Doppler Anemometry, The Potential For Measurements In Man.

    Science.gov (United States)

    Kilpatrick, Walker D.

    1984-10-01

    Fibre optic laser Doppler anemometry (FOLDA) is a useful technique for in vitro studies but has yet to be used successfully for the measurement of intravascular velocity in man. Some reasons for this are: 1. The difficulty of locating the position of the fibre within the vessel. 2. Lack of knowledge of the precise velocity profile across the vessel. 3. The effects of flow perturbation at the tip of the probe. These problems have been assessed using a FOLDA system developed in our laboratory. Three dimensional velocity profiles of blood flowing in arteries with and without stenoses have been plotted at different rates of flow. The results show that the parabolic profile of fully developed laminar flow is flattened in an arterial stenosis and the degree of flattening increases as flow increases. This means the relationship of the flow and velocity is nonlinear. Any use of FOLDA to assess vessel dimension must take this into account. The position of the fibre in the vessel can only be adequately controlled in in-vitro studies. The region of measurement is only 50 μm diameter and must be at the position of the peak velocity to enable quantitative measurement. Thus the technique is useful in humans only when there is a flat velocity profile such as in the coronary sinus. The relationship between coronary sinus flow and FOLDA velocity is linear in experimental animals. The current FOLDA system has a limited range of projection into the blood stream. The velocity is not linearly related to blood flow when the direction of flow is the same as the projected light, probably due to flow perturbation at the fibre tip. This means that a probe introduced into a coronary artey would not measure linear flow however a probe introduced against the flow could be used to assess the severity of peripheral arterial stenoses. To measure flow across a stenoses before and after angioplasty is possible but requires a method of obtaining an average spatial velocity before it is practicable.

  5. Postocclusive Hyperemia Measured with Laser Doppler Flowmetry and Transcutaneous Oxygen Tension in the Diagnosis of Primary Raynaud's Phenomenon: A Prospective, Controlled Study

    Science.gov (United States)

    Maga, Paweł; Henry, Brandon Michael; Kmiotek, Elizabeth K.; Gregorczyk-Maga, Iwona; Kaczmarczyk, Paweł; Niżankowski, Rafał

    2016-01-01

    The aim of this study was to measure the sensitivity and specificity of transcutaneous oxygen tension and postocclusive hyperemia testing using laser Doppler flowmetry in patients with primary Raynaud's phenomenon. One hundred patients and one hundred controls were included in the study. Baseline microvascular blood flow and then time to peak flow following occlusion were measured using laser Doppler flowmetry. Afterwards, the transcutaneous oxygen tension was recorded. The sensitivities of baseline microvascular blood flow, postocclusive time to peak flow, and transcutaneous oxygen tension were 79%, 79%, and 77%, respectively. The postocclusive time peak flow had a superior specificity of 90% and area under the curve of 0.92 as compared to 66% and 0.80 for baseline microvascular flow and 64% and 0.76 for transcutaneous oxygen tension. Time to postocclusive peak blood flow measured by laser Doppler flowmetry is a highly accurate test for differentiating patients with primary Raynaud's phenomenon from healthy controls. PMID:28101516

  6. Postocclusive Hyperemia Measured with Laser Doppler Flowmetry and Transcutaneous Oxygen Tension in the Diagnosis of Primary Raynaud's Phenomenon: A Prospective, Controlled Study.

    Science.gov (United States)

    Maga, Paweł; Henry, Brandon Michael; Kmiotek, Elizabeth K; Gregorczyk-Maga, Iwona; Kaczmarczyk, Paweł; Tomaszewski, Krzysztof A; Niżankowski, Rafał

    2016-01-01

    The aim of this study was to measure the sensitivity and specificity of transcutaneous oxygen tension and postocclusive hyperemia testing using laser Doppler flowmetry in patients with primary Raynaud's phenomenon. One hundred patients and one hundred controls were included in the study. Baseline microvascular blood flow and then time to peak flow following occlusion were measured using laser Doppler flowmetry. Afterwards, the transcutaneous oxygen tension was recorded. The sensitivities of baseline microvascular blood flow, postocclusive time to peak flow, and transcutaneous oxygen tension were 79%, 79%, and 77%, respectively. The postocclusive time peak flow had a superior specificity of 90% and area under the curve of 0.92 as compared to 66% and 0.80 for baseline microvascular flow and 64% and 0.76 for transcutaneous oxygen tension. Time to postocclusive peak blood flow measured by laser Doppler flowmetry is a highly accurate test for differentiating patients with primary Raynaud's phenomenon from healthy controls.

  7. Incorporation of a Redfern Integrated Optics ORION Laser Module with an IPG Photonics Erbium Fiber Laser to Create a Frequency Conversion Photon Doppler Velocimeter for US Army Research Laboratory Measurements: Hardware, Data Analysis, and Error Quantification

    Science.gov (United States)

    2017-04-01

    ARL-MR-0953● Apr 2017 US Army Research Laboratory Incorporation of a Redfern Integrated Optics ORION Laser Module with an IPG...Photonics Erbium Fiber Laser to Create a Frequency- Conversion Photon Doppler Velocimeter for US Army Research Laboratory Measurements: Hardware...Laboratory Incorporation of a Redfern Integrated Optics ORION Laser Module with an IPG Photonics Erbium Fiber Laser to Create a Frequency- Conversion

  8. Acute effects of vascular modifying agents in solid tumors assessed by noninvasive laser Doppler flowmetry and near infrared spectroscopy

    DEFF Research Database (Denmark)

    Kragh, Michael; Quistorff, Bjørn; Horsman, Michael R;

    2002-01-01

    The potential of noninvasive laser Doppler flowmetry (LDF) and near infrared spectroscopy (NIRS) to detect acute effects of different vascular-modifying agents on perfusion and blood volume in tumors was evaluated. C3H mouse mammary carcinomas (approximately 200 mm(3)) in the rear foot of CDF1 mice...... were treated with flavone acetic acid (FAA, 150 mg/kg), 5,6-dimethylxanthenone-4-acetic acid (DMXAA, 20 mg/kg), combretastatin A-4 disodium phosphate (CA4DP, 250 mg/kg), hydralazine (HDZ, 5 mg/kg), or nicotinamide (NTA, 500 mg/kg). Tumor perfusion before and after treatment was evaluated by noninvasive...... LDF, using a 41 degrees C heated custom-built LDF probe with four integrated laser/receiver units, and tumor blood volume was estimated by NIRS, using light guide coupled reflectance measurements at 800+/-10 nm. FAA, DMXAA, CA4DP, and HDZ significantly decreased tumor perfusion by 50%, 47%, 73...

  9. Three-dimensional ray tracing through curvilinear interfaces with application to laser Doppler anemometry in a blood analogue fluid.

    Science.gov (United States)

    Nugent, Allen H; Bertram, Christopher D

    2010-02-01

    Prediction of the effects of refractive index (RI) mismatch on laser Doppler anemometer (LDA) measurements within a curvilinear cavity (an artificial ventricle) was achieved by developing a general technique for modelling the paths of the convergent beams of the LDA system using 3D vector geometry. Validated by ray tracing through CAD drawings, the predicted maximum tolerance in RI between the solid model and the working fluid was +/- 0.0005, equivalent to focusing errors commensurate with the geometric and alignment uncertainties associated with the flow model and the LDA arrangement. This technique supports predictions of the effects of refraction within a complex geometry. Where the RI mismatch is unavoidable but known, it is possible not only to calculate the true position of the measuring volume (using the probe location and model geometry), but also to estimate degradation in signal quality arising from differential displacement and refraction of the laser beams.

  10. High-contrast sub-Doppler absorption spikes in a hot atomic vapor cell exposed to a dual-frequency laser field

    Science.gov (United States)

    Abdel Hafiz, Moustafa; Brazhnikov, Denis; Coget, Grégoire; Taichenachev, Alexei; Yudin, Valeriy; de Clercq, Emeric; Boudot, Rodolphe

    2017-07-01

    The saturated absorption technique is an elegant method widely used in atomic and molecular physics for high-resolution spectroscopy, laser frequency standards and metrology purposes. We have recently discovered that a saturated absorption scheme with a dual-frequency laser can lead to a significant sign reversal of the usual Doppler-free dip, yielding a deep enhanced-absorption spike. In this paper, we report detailed experimental investigations of this phenomenon, together with a full in-depth theoretical description. It is shown that several physical effects can support or oppose the formation of the high-contrast central spike in the absorption profile. The physical conditions for which all these effects act constructively and result in very bright Doppler-free resonances are revealed. Apart from their theoretical interest, results obtained in this manuscript are of great interest for laser spectroscopy and laser frequency stabilization purposes, with applications in laser cooling, matter-wave sensors, atomic clocks or quantum optics.

  11. A polaritonic two-component Bose-Hubbard model

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M J; Brandao, F G S L; Plenio, M B [Institute for Mathematical Sciences, Imperial College London, 53 Exhibition Road, SW7 2PE (United Kingdom)], E-mail: m.hartmann@imperial.ac.uk

    2008-03-15

    We demonstrate that polaritons in an array of interacting micro-cavities with strong atom-photon coupling can form a two-component Bose-Hubbard model in which both polariton species are protected against spontaneous emission as their atomic part is stored in two ground states of the atoms. The parameters of the effective model can be tuned via the driving strength of external lasers and include attractive and repulsive polariton interactions. We also describe a method to measure the number statistics in one cavity for each polariton species independently.

  12. Multi-channel laser Doppler velocimetry using a two-dimensional optical fiber array for obtaining instantaneous velocity distribution characteristics

    Science.gov (United States)

    Kyoden, Tomoaki; Yasue, Youichi; Ishida, Hiroki; Akiguchi, Shunsuke; Andoh, Tsugunobu; Takada, Yogo; Teranishi, Tsunenobu; Hachiga, Tadashi

    2015-01-01

    A laser Doppler velocimeter (LDV) has been developed that is capable of performing two-dimensional (2D) cross-sectional measurements. It employs two horizontal laser light sheets that intersect at an angle of 13.3°. Since the intersection region is thin, it can be used to approximately determine the 2D flow field. An 8 × 8 array of optical fibers is used to simultaneously measure Doppler frequencies at 64 points. Experiments were conducted to assess the performance of the LDV, and it was found to be capable of obtaining spatial and temporal velocity information at multiple points in a flow field. The technique is fast, noninvasive, and accurate over long sampling periods. Furthermore, its applicability to an actual flow field was confirmed by measuring the temporal velocity distribution of a pulsatile flow in a rectangular flow channel with an obstruction. The proposed device is thus a useful, compact optical instrument for conducting simultaneous 2D cross-sectional multipoint measurements.

  13. Concurrent Reflectance Confocal Microscopy and Laser Doppler Flowmetry to Improve Skin Cancer Imaging: A Monte Carlo Model and Experimental Validation

    Science.gov (United States)

    Mowla, Alireza; Taimre, Thomas; Lim, Yah Leng; Bertling, Karl; Wilson, Stephen J.; Prow, Tarl W.; Soyer, H. Peter; Rakić, Aleksandar D.

    2016-01-01

    Optical interrogation of suspicious skin lesions is standard care in the management of skin cancer worldwide. Morphological and functional markers of malignancy are often combined to improve expert human diagnostic power. We propose the evaluation of the combination of two independent optical biomarkers of skin tumours concurrently. The morphological modality of reflectance confocal microscopy (RCM) is combined with the functional modality of laser Doppler flowmetry, which is capable of quantifying tissue perfusion. To realize the idea, we propose laser feedback interferometry as an implementation of RCM, which is able to detect the Doppler signal in addition to the confocal reflectance signal. Based on the proposed technique, we study numerical models of skin tissue incorporating two optical biomarkers of malignancy: (i) abnormal red blood cell velocities and concentrations and (ii) anomalous optical properties manifested through tissue confocal reflectance, using Monte Carlo simulation. We also conduct a laboratory experiment on a microfluidic channel containing a dynamic turbid medium, to validate the efficacy of the technique. We quantify the performance of the technique by examining a signal to background ratio (SBR) in both the numerical and experimental models, and it is shown that both simulated and experimental SBRs improve consistently using this technique. This work indicates the feasibility of an optical instrument, which may have a role in enhanced imaging of skin malignancies. PMID:27598157

  14. Concurrent Reflectance Confocal Microscopy and Laser Doppler Flowmetry to Improve Skin Cancer Imaging: A Monte Carlo Model and Experimental Validation

    Directory of Open Access Journals (Sweden)

    Alireza Mowla

    2016-09-01

    Full Text Available Optical interrogation of suspicious skin lesions is standard care in the management of skin cancer worldwide. Morphological and functional markers of malignancy are often combined to improve expert human diagnostic power. We propose the evaluation of the combination of two independent optical biomarkers of skin tumours concurrently. The morphological modality of reflectance confocal microscopy (RCM is combined with the functional modality of laser Doppler flowmetry, which is capable of quantifying tissue perfusion. To realize the idea, we propose laser feedback interferometry as an implementation of RCM, which is able to detect the Doppler signal in addition to the confocal reflectance signal. Based on the proposed technique, we study numerical models of skin tissue incorporating two optical biomarkers of malignancy: (i abnormal red blood cell velocities and concentrations and (ii anomalous optical properties manifested through tissue confocal reflectance, using Monte Carlo simulation. We also conduct a laboratory experiment on a microfluidic channel containing a dynamic turbid medium, to validate the efficacy of the technique. We quantify the performance of the technique by examining a signal to background ratio (SBR in both the numerical and experimental models, and it is shown that both simulated and experimental SBRs improve consistently using this technique. This work indicates the feasibility of an optical instrument, which may have a role in enhanced imaging of skin malignancies.

  15. Concurrent Reflectance Confocal Microscopy and Laser Doppler Flowmetry to Improve Skin Cancer Imaging: A Monte Carlo Model and Experimental Validation.

    Science.gov (United States)

    Mowla, Alireza; Taimre, Thomas; Lim, Yah Leng; Bertling, Karl; Wilson, Stephen J; Prow, Tarl W; Soyer, H Peter; Rakić, Aleksandar D

    2016-09-01

    Optical interrogation of suspicious skin lesions is standard care in the management of skin cancer worldwide. Morphological and functional markers of malignancy are often combined to improve expert human diagnostic power. We propose the evaluation of the combination of two independent optical biomarkers of skin tumours concurrently. The morphological modality of reflectance confocal microscopy (RCM) is combined with the functional modality of laser Doppler flowmetry, which is capable of quantifying tissue perfusion. To realize the idea, we propose laser feedback interferometry as an implementation of RCM, which is able to detect the Doppler signal in addition to the confocal reflectance signal. Based on the proposed technique, we study numerical models of skin tissue incorporating two optical biomarkers of malignancy: (i) abnormal red blood cell velocities and concentrations and (ii) anomalous optical properties manifested through tissue confocal reflectance, using Monte Carlo simulation. We also conduct a laboratory experiment on a microfluidic channel containing a dynamic turbid medium, to validate the efficacy of the technique. We quantify the performance of the technique by examining a signal to background ratio (SBR) in both the numerical and experimental models, and it is shown that both simulated and experimental SBRs improve consistently using this technique. This work indicates the feasibility of an optical instrument, which may have a role in enhanced imaging of skin malignancies.

  16. A mobile incoherent Mie-Rayleigh Doppler wind lidar with a single frequency and tunable operation of an injection Nd︰YAG laser

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    A mobile incoherent Doppler lidar system has been experimentally demonstrated to be able to transmit reliable single frequency operation laser pulse, even after truck transit and in very high vibration environments. The linewidth of the injection-seeded pulse Nd:YAG laser can be measured by means of an I2 molecular filter. And, lidar validation experiments demonstrated the feasibility and capability of measuring wind field by the Mie-Rayleigh Doppler wind lidar. The uncertainty of measured wind speed is 0.985m/s in the altitude range from 2 to 4 km.

  17. Simultaneous assessment of blood flow in UVB-inflamed human skin by laser Doppler flowmetry and the 133-xenon cashout technique

    DEFF Research Database (Denmark)

    1991-01-01

    The purpose of the study was to compare skin bloood flow by laser Doppler flowmetry (LDF) and the 133-Xenon washout technique in UVB-inflamed human skin. Six healthy subjects participated in the study. Forearm skin blood flow was measured prior to irradiation and then 8, 24, 48 and 72 h the expos......The purpose of the study was to compare skin bloood flow by laser Doppler flowmetry (LDF) and the 133-Xenon washout technique in UVB-inflamed human skin. Six healthy subjects participated in the study. Forearm skin blood flow was measured prior to irradiation and then 8, 24, 48 and 72 h...

  18. Two-component model of solar plages

    Institute of Scientific and Technical Information of China (English)

    LI; Jianping(李建平); DING; Mingde(丁明德); FANG; Cheng(方成)

    2002-01-01

    By use of the 2-m Mcmath-Pierce telescope at Kitt Peak, the high-quality spectra of a plage with moderate brightness near the center of solar disk were obtained. The data include seven spectral lines, which are Hα, Hβ, CaII H and K lines and the infrared triplet. With the consideration of fine structures of solar plages, a two-component atmospheric model is constructed by keeping the cool component to be the quiet atmosphere. Three cases of the hot component are given for different filling factors where the temperature and density distribution are adjusted in order to reproduce the seven observed spectral profiles. We also briefly discuss the influence of the column density at the base of the corona, m0, and the macro-turbulent velocity on the required filling factor and computed profiles. The two-component model is compared with precious one-component semi-empirical models. The limitation of the model is pointed out and further improvement is indicated.

  19. ANALYTICAL CALCULATIONS AND MONTE-CARLO SIMULATIONS OF LASER DOPPLER FLOWMETRY USING A CUBIC LATTICE MODEL

    NARCIS (Netherlands)

    KOELINK, MH; DEMUL, FFM; GREVE, J; GRAAFF, R; DASSEL, ACM; AARNOUDSE, JG

    1992-01-01

    In addition to the static cubic lattice model for photon migration in turbid biological media by Bonner et al. [J. Opt. Soc. Am. A 4, 423-432 (1987)], a dynamic method is presented to calculate the average absolute Doppler shift as a function of the distance between the point of injection of photons

  20. Laser Doppler bloedflow metingen aan de huid : metingen en Monte Carlo simulaties

    NARCIS (Netherlands)

    Koelink, M.H.; Nijholt, J.L.M.

    1992-01-01

    Er bestaan verschillende technieken om de snelheid van de bloedflow in de menselijke huid te meten: thermische technieken (sound-Doppler), wash-out technieken gebaseerd op het labelen van deeltjes opgelost in de vloeistof en nog andere waaronder recentelijk kernspinresonantie (MRI) en electronspinre

  1. Comparative study of the performance of semiconductor laser based coherent Doppler lidars

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2012-01-01

    Coherent Doppler Lidars (CDLs), operating at an eye-safe 1.5-micron wavelength, have found promising applications in the optimization of wind-power production. To meet the wind-energy sector's impending demand for more cost-efficient industrial sensors, we have focused on the development...

  2. Two Component Signal Transduction in Desulfovibrio Species

    Energy Technology Data Exchange (ETDEWEB)

    Luning, Eric; Rajeev, Lara; Ray, Jayashree; Mukhopadhyay, Aindrila

    2010-05-17

    The environmentally relevant Desulfovibrio species are sulfate-reducing bacteria that are of interest in the bioremediation of heavy metal contaminated water. Among these, the genome of D. vulgaris Hildenborough encodes a large number of two component systems consisting of 72 putative response regulators (RR) and 64 putative histidinekinases (HK), the majority of which are uncharacterized. We classified the D. vulgaris Hildenborough RRs based on their output domains and compared the distribution of RRs in other sequenced Desulfovibrio species. We have successfully purified most RRs and several HKs as His-tagged proteins. We performed phospho-transfer experiments to verify relationships between cognate pairs of HK and RR, and we have also mapped a few non-cognate HK-RR pairs. Presented here are our discoveries from the Desulfovibrio RR categorization and results from the in vitro studies using purified His tagged D. vulgaris HKs and RRs.

  3. Two-Component Description for Relativistic Fermions

    Institute of Scientific and Technical Information of China (English)

    CHEN Yu-Qi; SANG Wen-Long; YANG Lan-Fei

    2009-01-01

    We propose a two-component form to describe massive relativistic fermions in gauge theories. Relations between the Green's functions in this form and those in the conventional four-component form are derived. It is shown that the S-matrix elements in both forms are exactly the same. The description of the fermion in the new form simplifies significantly the γ-matrix algebra in the four-component form. In particular, in perturbative calculations the propagator of the fermion is a scalar function. As examples, we use this form to reproduce the relativistic spectrum of hydrodron atom, the S-matrix of e+ e-→μ+ μ- and QED one-loop vacuum polarization of photon.

  4. Using ordinal logistic regression to evaluate the performance of laser-Doppler predictions of burn-healing time

    Directory of Open Access Journals (Sweden)

    Pape Sarah A

    2009-02-01

    Full Text Available Abstract Background Laser-Doppler imaging (LDI of cutaneous blood flow is beginning to be used by burn surgeons to predict the healing time of burn wounds; predicted healing time is used to determine wound treatment as either dressings or surgery. In this paper, we do a statistical analysis of the performance of the technique. Methods We used data from a study carried out by five burn centers: LDI was done once between days 2 to 5 post burn, and healing was assessed at both 14 days and 21 days post burn. Random-effects ordinal logistic regression and other models such as the continuation ratio model were used to model healing-time as a function of the LDI data, and of demographic and wound history variables. Statistical methods were also used to study the false-color palette, which enables the laser-Doppler imager to be used by clinicians as a decision-support tool. Results Overall performance is that diagnoses are over 90% correct. Related questions addressed were what was the best blood flow summary statistic and whether, given the blood flow measurements, demographic and observational variables had any additional predictive power (age, sex, race, % total body surface area burned (%TBSA, site and cause of burn, day of LDI scan, burn center. It was found that mean laser-Doppler flux over a wound area was the best statistic, and that, given the same mean flux, women recover slightly more slowly than men. Further, the likely degradation in predictive performance on moving to a patient group with larger %TBSA than those in the data sample was studied, and shown to be small. Conclusion Modeling healing time is a complex statistical problem, with random effects due to multiple burn areas per individual, and censoring caused by patients missing hospital visits and undergoing surgery. This analysis applies state-of-the art statistical methods such as the bootstrap and permutation tests to a medical problem of topical interest. New medical findings are

  5. Evaluation of late radiation-induced changes of the superficial microcirculation. I. clinical benefit of the cutaneous Doppler laser; Evaluation des modifications radio-induites tardives de la microcirculation superficielle. I. apport clinique du laser doppler cutane

    Energy Technology Data Exchange (ETDEWEB)

    Delanian, S. [Hopital Saint-Louis, Service d' Oncologie-Radiotherapie, 75 - Paris (France); Lefaix, J.L. [CEA/DAM-Ile de France, DSV-DRR, 91 - Bruyeres-Le-Chatel (France)

    2000-12-01

    Objective. - The changes that occur in the tissular microcirculation after therapeutic irradiation (RT) account for some of the late effects of irradiation, especially on the cutaneous level. As a rule, the methods of exploring the superficial microcirculation only measure blood flow indirectly. Only the Doppler laser can provide direct measurements of blood parameters in vivo in man. Methods. -Thirty women who had been irradiated with 45 + 20 Gy of locoregional fractionated adjuvant RT for breast cancer developed local radiation-induced fibrosis six years later ({+-}5). The local microcirculation was measured in the resting state and during thermal stimulation at 42 deg. C, using a Periflux cutaneous Doppler laser with p413 probes. Three periods of six minutes each were continuously recorded: period 1 (P1) represented basal resting cutaneous perfusion, with the slope p corresponding to the increase in perfusion when two minutes of thermal stimulation at 42 deg. C began; P2 to plateau perfusion during this stimulation; and P3 to perfusion on the return to equilibrium. Each individual was its own control. Results. - In the women treated by RT, the resting microcirculation in the skin underlying an area of late fibrosis rose by a factor of 2 during P1 (p < 0.001), and the P2/P1 ratio decreased by a factor of 2 (p < 0.001), compared to the control area. After thermal stimulation, there was no change in p, P2 or P3. Conclusion. -Although a hypo-vascularization is frequently found in late sequelae of RT, we observed an increase of the cutaneous microcirculation associated with a maladjustment of the endothelial response to a thermal stimulation. These observations seem to reflect the presence of dilated new capillaries of the telangiectatic type, which are macroscopically undetectable. (authors)

  6. Glucagon-like peptide-2 stimulates mucosal microcirculation measured by laser Doppler flowmetry in end-jejunostomy short bowel syndrome patients

    DEFF Research Database (Denmark)

    Høyerup, P; Hellström, P M; Schmidt, P T;

    2013-01-01

    In animal and human studies glucagon-like peptide-2 (GLP-2) has been shown to increase blood flow in the superior mesenteric artery and the portal vein. This study describes the effect of GLP-2 measured directly on the intestinal mucosal blood flow by laser Doppler flowmetry (LDF) in end-jejunost...

  7. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...... the detected doppler frequency. It is found that the doppler frequency for this particular setup is independent of the direction of detection. Investigations of the signal-to-noise ratio (SNR) show that the maximum SNR-considering the optical setup-is obtained by measuring the frequency difference between two...

  8. Evaluation of laser Doppler flowmetry for measuring coronary band and laminar microcirculatory blood flow in clinically normal horses.

    Science.gov (United States)

    Adair, H S; Goble, D O; Shires, G M; Sanders, W L

    1994-04-01

    Once daily for 3 days, laser Doppler flowmetry was used in 5 healthy, nonsedated adult horses to evaluate coronary band and laminar microcirculatory blood flow (MBF) in both forelimbs. The coronary band had significantly (P measurement period in any one site. Significant (P laminar MBF. On occlusion of the digital arteries at the level of the fetlock, marked decrease in coronary band and laminar MBF was observed. Twenty minutes after IV administration of acetylpromazine, marked increase in coronary band and laminar MBF was observed. The technique was easily performed in standing nonsedated horses, did not inflict discomfort, lacked complications, and measurements were repeatable. This technique provides an index of digital MBF, either intermittently or continuously, avoiding introduction of invasive variables associated with other techniques.

  9. Estimating mechanical blood trauma in a centrifugal blood pump: laser Doppler anemometer measurements of the mean velocity field.

    Science.gov (United States)

    Pinotti, M; Paone, N

    1996-06-01

    A laser Doppler anemometer (LDA) was used to obtain the mean velocity and the Reynolds stress fields in the inner channels of a well-known centrifugal vaneless pump (Bio-pump). Effects of the excessive flow resistance against which an occlusive pump operates in some surgical situations, such as cardiopulmonary bypass, are illustrated. The velocity vector field obtained from LDA measurements reveals that the constraint-forced vortex provides pumping action in a restricted area in the core of the pump. In such situations, recirculating zones dominate the flow and consequently increase the damage to blood cells and raise the risk of thrombus formation in the device. Reynolds normal and shear stress fields were obtained in the entry flow for the channel formed by two rotating cones to illustrate the effects of flow disturbances on the potential for blood cell damage.

  10. Steady flow in a model of the human carotid bifurcation. Part II--laser-Doppler anemometer measurements.

    Science.gov (United States)

    Bharadvaj, B K; Mabon, R F; Giddens, D P

    1982-01-01

    The evidence for hypothesizing a relationship between hemodynamics and atherogenesis as well as the motivation for selecting the carotid bifurcation for extensive fluid dynamic studies has been discussed in Part I of this two-paper sequence. Part II deals with velocity measurements within the bifurcation model described by Fig. 1 and Table 1 of the previous paper. A plexiglass model conforming to the dimensions of the average carotid bifurcation was machined and employed for velocity measurements with a laser-Doppler anemometer (LDA). The objective of this phase of the study was to obtain quantitative information on the velocity field and to estimate levels and directions of wall shear stress in the region of the bifurcation.

  11. Effect of swimming training on neural microcirculation in rats with sciatic nerve compression A study based on laser Doppler flowmetry

    Institute of Scientific and Technical Information of China (English)

    Yueming Gao; Xinglin Wang; Senyang Lang; Lining Zhang; Wei Suo; Tianyu Jiang; Jingping Fan

    2010-01-01

    Microcirculation of the peripheral nerve is necessary for neural growth and regeneration.However,technical limitations have limited studies in this area.The few studies conducted have concerned active exercise effects on microcirculation of the peripheral nerve.Using an animal experiment,this study evaluated the effect of swimming training on microcirculation of injured peripheral nerve by laser Doppler flowmetry.The results showed that the blood vessel at the distal end of the peripheral nerve was the main blood supply for the nerve,and the internal blood supply for the nerve had strong compensatory ability.Swimming training promoted the functional recovery of rats with sciatic nerve injury and the regeneration of myelin sheath and blood vessels,but had no impact on neural blood flow.

  12. Laser Doppler velocimeter investigation of trailing vortices behind a semi-span swept wing in a landing configuration

    Science.gov (United States)

    Ciffone, D. L.; Orloff, K. L.; Grant, G. R.

    1973-01-01

    Measured axial and tangential velocity profiles in the near wake vortices of a semi-span model of the Convair 990 wing in the NASA-Ames 7- by 10-foot wind tunnel are presented. A scanning laser Doppler velocimeter was used to obtain data at two different downstream stations (0.49 and 1.25 wing spans) at various angles of attack and configurations from wing alone to wing plus nacelles, anti-shock bodies, and flaps deflected 27 deg (landing configuration). It is shown that the velocity distributions within the wake are quite sensitive to span loading. Specifically, it is illustrated that an aircraft flying at given lift coefficient (C SUB L), can substantially reduce its trailing vortex upset potential by deploying its flaps and altering its flight attitude to maintain the same C SUB L. This might be taken into consideration along with performance and noise considerations in the selection of aircraft approach lift over drag.

  13. An LDA (Laser-Doppler Anemometry) investigation of three-dimensional normal shock wave boundary-layer interactions

    Science.gov (United States)

    Chriss, R. M.; Hingst, W. R.; Strazisar, A. J.; Keith, T. G., Jr.

    1989-01-01

    Nonintrusive measurements were made of a normal shock wave/boundary layer interaction. Two dimensional measurements were made throughout the interaction region while 3-D measurements were made in the vicinity of the shock wave. The measurements were made in the corner of the test section of a continuous supersonic wind tunnel in which a normal shock wave had been stabilized. Laser Doppler Anemometry, surface pressure measurement and flow visualization techniques were employed for two freestream Mach number test cases: 1.6 and 1.3. The former contained separated flow regions and a system of shock waves. The latter was found to be far less complicated. The results define the flow field structure in detail for each case.

  14. Tobacco two-component gene NTHK2

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    By using a previously isolated tobacco two- component gene NTHK1 as a probe, we screened a cDNA library and obtained a homologous gene designated NTHK2. Sequencing analysis revealed that NTHK2 encoded a putative ethylene receptor homolog and contained a histidine kinase domain and a receiver domain. In the histidine kinase domain, the histidine at the phosphorylation site was replaced by an asparagine. Southern analysis indicated that NTHK2 was present at low copies in tobacco genome. The expression of NTHK2 was studied using a competitive RT-PCR method. It was found that, in young flower buds, NTHK2 was expressed abundantly, while in other organs or tissues, it was expressed in a low level. When leaf was subjected to wounding (cutting) treatment, NTHK2 expression was increased. When tobacco seedlings were stressed with PEG and heat shock, NTHK2 transcription was also enhanced. Other treatments showed little effects. These results indicated that NTHK2 might be involved in the developmental processes and in plant responses to some environmental stresses.

  15. Effects of permanent magnets on resting skin blood perfusion in healthy persons assessed by laser Doppler flowmetry and imaging.

    Science.gov (United States)

    Mayrovitz, H N; Groseclose, E E; Markov, M; Pilla, A A

    2001-10-01

    Effects on skin blood perfusion of permanent ceramic magnets [0.1 T (1000 G) surface field], individually (disk shaped, 4 cm diameter x 1 cm thick) or in the form of a 11 x 7 in pad ( approximately 28 x 17.8 cm) with an array of 16 rectangular magnets (4.5 x 2.2 cm), were investigated in 16 female volunteers (27.4 +/- 1.7 years, range 21-48 years) using three separate protocols. In protocol A, a disk magnet was placed on the palmar surface of the hand in contact with the thenar eminence (n = 5). In protocol B, the magnet was placed on the hand dorsum overlying the thenar eminence (n = 5). In protocol C, the entire palm and fingers rested on the magnetic pad (n = 6). Magnets were in place for 36 min on one hand, and a sham was in place on the other hand. Blood perfusion was measured on the middle finger dorsum by laser Doppler flowmetry (LDF) and on the index finger by laser Doppler imaging (LDI). Perfusion measurements were simultaneously taken in sham and magnet exposed hands, before and during the entire magnet exposure interval. Magnetic field effects were tested by comparing skin blood perfusion sequences in magnet and sham exposed regions. Results showed no significant changes in either LDF or LDI perfusion at magnet or sham sites during exposure, nor were there any significant differences between sham and magnet sites for any protocol. Measurements of skin temperature at the LDF measurement sites also showed no significant change. It is concluded that in the healthy subjects studied with normal, unstressed circulation, magnets of the type and for the duration used, showed no detectible effect on skin blood perfusion in the anatomical area studied.

  16. Contribution of laser Doppler flowmetry with venoarteriolar reflex, cold, and rewarming testing, and intravital capillaroscopy to diagnose Raynaud's phenomenon

    Directory of Open Access Journals (Sweden)

    Zeman J

    2014-05-01

    Full Text Available Jan Zeman,1 Oksana Turyanytsya,1 Vojtĕch Kapsa,2 Mojmír Eliáš3 1Department of Clinical Cardiology and Angiology, Hospital Bulovka, 2Charles University in Prague, Faculty of Mathematics and Physics, 3Kooperativa a.s., Pobrezni, Prague, Czech Republic Background: The early differential diagnosis of Raynaud’s phenomenon (RP is crucial for the prognosis and therapy of these patients. In our microcirculatory laboratory, we use intravital capillaroscopy (IC, plethysmography (P, and laser Doppler flowmetry (LDF for examining acrosyndromes. We combine LDF with venoarteriolar reflex test, cold test, and rewarming test to achieve more reliable diagnoses of acrosyndromes. Patients and methods: We examined LDF and IC according to a strict protocol using a battery of tests (venoarteriolar reflex test, cold test, rewarming test applied to five different groups of people and compared their results: healthy controls, primary Raynaud’s phenomenon (PRP, systemic scleroderma, vibration white finger, and peripheral artery occlusive disease. Our tests included 340 individuals (72 patients plus 268 controls. Results: Although all tests provided some differences between controls and patients, only the rewarming test offered significant results for differential diagnoses. Conclusion: IC and LDF combined with the battery of tests (venoarteriolar reflex test, cold test, rewarming test under standard conditions can be used as reliable tools to distinguish between PRP and some types of secondary RP (especially in the case of systemic scleroderma, vibration white fingers, or peripheral artery occlusive disease; RPs with organic occlusions of the small arteries causing the diseases. Our methodology can help to distinguish between other types of RP, as well. Keywords: Raynaud’s phenomenon, acrosyndrome, laser Doppler flowmetry, intravital capillaroscopy, scleroderma, vibration white finger, peripheral artery occlusive disease

  17. Laser Doppler line scanner for monitoring skin perfusion changes of port wine stains during vascular-targeted photodynamic therapy

    Science.gov (United States)

    Chen, Defu; Ren, Jie; Wang, Ying; Gu, Ying

    2014-11-01

    Vascular-targeted photodynamic therapy (V-PDT) is known to be an effective therapeutic modality for the treatment of port wine stains (PWS). Monitoring the PWS microvascular response to the V-PDT is crucial for improving the effectiveness of PWS treatment. The objective of this study was to use laser Doppler technique to directly assess the skin perfusion in PWS before and during V-PDT. In this study, 30 patients with PWS were treated with V-PDT. A commercially laser Doppler line scanner (LDLS) was used to record the skin perfusion of PWS immediately before; and at 1, 3, 5, 7, 10, 15 and 20 minutes during V-PDT treatment. Our results showed that there was substantial inter- and intra-patient perfusion heterogeneity in PWS lesion. Before V-PDT, the comparison of skin perfusion in PWS and contralateral healthy control normal skin indicated that PWS skin perfusion could be larger than, or occasionally equivalent to, that of control normal skin. During V-PDT, the skin perfusion in PWS significantly increased after the initiation of V-PDT treatment, then reached a peak within 10 minutes, followed by a slowly decrease to a relatively lower level. Furthermore, the time for reaching peak and the subsequent magnitude of decrease in skin perfusion varied with different patients, as well as different PWS lesion locations. In conclusion, the LDLS system is capable of assessing skin perfusion changes in PWS during V-PDT, and has potential for elucidating the mechanisms of PWS microvascular response to V-PDT.

  18. Raman-shifted eye-safe aerosol lidar (REAL) in 2010: instrument status and two-component wind measurements

    Science.gov (United States)

    Mayor, Shane D.

    2010-10-01

    This paper and corresponding seminar given on 20 September 2010 at the 16th International School for Quantum Electronics in Nesebar, Bulgaria, will describe the key hardware aspects of the Raman-shifted Eye-safe Aerosol Lidar (REAL) and recent advances in extracting two-component wind vector fields from the images it produces. The REAL is an eye-safe, ground-based, scanning, elastic aerosol backscatter lidar operating at 1.54 microns wavelength. Operation at this wavelength offers several advantages compared to other laser wavelengths including: (1) maximum eye-safety, (2) invisible beam, (3) superior performance photodetectors compared with those used at longer wavelengths, (4) low atmospheric molecular scattering when compared with operation at shorter wavelengths, (5) good aerosol backscattering, (6) atmospheric transparency, and (7) availability of optical and photonic components used in the modern telecommunations industry. A key issue for creating a high-performance direct-detection lidar at 1.5 microns is the use of InGaAs avalanche photodetectors that have active areas of at most 200 microns in diameter. The small active area imposes a maximum limitation on the field-of-view of the receiver (about 0.54 mrad full-angle for REAL). As a result, a key requirement is a transmitter that can produce a pulsed (>10 Hz) beam with low divergence (150 mJ), and short pulse-duration (lidars in that two components of motion can be sensed. (Doppler lidars can sense only the radial component of flow.) Two-component velocity estimation is done by computing two-dimensional cross-correlation functions (CCFs) and noting the displacement of the peak of the CCF with respect to the origin. Motion vectors derived from this method are compared with coincident sonic anemometer measurements at 1.6 km range. Preliminary results indicate the method performs best when the atmosphere is stable with light winds.

  19. Measurements of ultrasonic waves by means of laser Doppler velocimeter and an experimental study of elastic wave propagation in inhomogeneous media; Laser doppler sokudokei ni yoru choonpa keisoku to ganseki wo mochiita fukinshitsu baishitsu no hado denpa model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, O.; Sato, T. [Geological Survey of Japan, Tsukuba (Japan); Lei, X. [Dia Consultants Company, Tokyo (Japan)

    1996-05-01

    In the study of seismic wave propagation, a model experimenting technique has been developed using a laser Doppler velocimeter (LDV) as the sensor. This technique, not dependent on conventional piezoelectric devices, only irradiates the specimen with laser to measure the velocity amplitude on the target surface, eliminating the need for close contact between the specimen and sensor. In the experiment, elastic penetration waves with their noise levels approximately 0.05mm/s were observed upon application of vibration of 10{sup 6}-10{sup 5}Hz. The specimen was stainless steel or rock, and waveforms caught by the LDV and piezoelectric device were compared. As the result, it was found that the LDV is a powerful tool for effectively explaining elastic wave propagation in inhomogeneous media. The piezoelectric device fails to reproduce accurately the waves to follow the initial one while the LDV detect the velocity amplitude on the specimen surface in a wide frequency range encouraging the discussion over the quantification of observed waveforms. 10 refs., 7 figs.

  20. The "Swiss-cheese Doppler-guided laser tonsillectomy": a new safe cribriform approach to intracapsular tonsillectomy.

    Science.gov (United States)

    Palmieri, B; Iannitti, T; Fistetto, G; Rottigni, V

    2013-05-01

    Outpatient laser ablation of palatine tonsils is a very interesting procedure that has been recently introduced as a routine in head and neck surgery departments. The aim of this study was to describe a new strategy using a Doppler-guided fibre optic neodymium-yttrium-aluminium-garnet (YAG) laser to remove up to 80 % of tonsillar tissue, as assessed in the long-term postoperative clinical evaluation of the volume of the tonsils at the follow-up, and leaving the capsule in place, thus avoiding any haemorrhagic complication and minimize pain. A total of 20 patients (men, n=13; women, n=7), aged between 6 and 63, were recruited for the procedure. They were affected by chronic hypertrophic tonsillitis with a recurrent fever and other symptoms that were related to oral inflammation. Among the 20 patients, no serious adverse events, including haemorrhage-related complications, were observed. Treatment was well tolerated, even in patients displaying an overall low pain threshold. No dropout or uncompleted procedure occurred in the present study. Minor complications included sore throat, moderate oedema, mild acute pharynx inflammation, slight peritonsillar exudate and local burning. The postoperative pain, measured by Scott-Huskisson visual analogue scale, was between 5 and 40 mm and was easily counteracted by means of external ice packages and nonsteroidal anti-inflammatory drugs, according to the individual patient's need. During the 12-36-month follow-up patients showed improved symptoms (n=7) and complete recovery (n=13). A relapse episode was observed in two patients. This study supports fibre optic laser neodymium-YAG tonsil surgery, named "cribriform intracapsular tonsillectomy" or "Swiss-cheese laser tonsillectomy", as an effective alternative to the traditional cold knife approach or electrosurgery. This approach could become the gold standard for tonsil surgery in the third millennium for safety reasons, acceptable cost-benefit ratio, the precise targeting of

  1. Study of Submicron Particle Size Distribution by Laser Doppler Measurement of Brownian Motion.

    Science.gov (United States)

    1987-01-30

    regime considered here, heat transfer from the submicron particles by forced convection and natural convection are negligible due to the extremely small...physical processes begin to influence the Brownian motion characteristics at high laser beam intensity. An analysis of the effects of thermophoresis and...photon pressure was carried out. The effect of thermophoresis due to the uneven heating of the particle by the laser beam was found to be a major

  2. Nd:YAG laser bloodless tonsillectomy by fiber optic doppler coupled handpiece beam delivery

    Science.gov (United States)

    Palmieri, Beniamino; Rottigni, Valentina

    2012-09-01

    Laser ablation of palatine tonsils is a relatively new technique recently performed in head and neck surgery departments, in order to treat recurrent tonsillar infections or obstructions from enlarged tonsils. In our study, we have investigated a new procedure using the fiber optic laser beam Nd:YAG to remove up to the 89% of tonsillar tissue, and leaving in place the capsule avoiding any hemorrhagic complication and limiting the pain.

  3. Investigations of unsteady flow in the draft tube of the pump- turbine model using laser Doppler anemometry

    Science.gov (United States)

    Kaznacheev, A.; Kuznetsov, I.

    2014-03-01

    The measurements and video observation of unsteady flow in the draft tube cone of the pump-turbine model were conducted in the Laboratory of Water Turbines, property of OJSC "Power machines" - "LMZ". The prototype head was about 250 m. The experiments were performed for the turbine mode of operation. Measurements were taken for the unit speed value n11 corresponding to rated head in the generating mode of operation, for a wide range of guide vanes openings at loads ranging from partial to maximum value. The researches of the velocity field in function of the Thoma number were carried out in some operating conditions. The mean values and RMS deviations of the velocity components were the results of laser measurements. The curves of the intensity of the vortex versus the guide vane opening and the Thoma number were plotted. The energy velocity spectra were presented for the points at which the most pronounced frequency precession of the helical axial vortex was observed. Video recording and laser Doppler anemometry were made in the operating conditions of the developed cavitation. Based on the results of video observations and energy spectra obtained via LDA, vortex frequencies were determined i.e. the frequencies of the vortex precession under the runner in the draft tube cone.

  4. Thermographic laser Doppler velocimetry using the phase-shifted luminescence of BAM:Eu(2+) phosphor particles for thermometry.

    Science.gov (United States)

    Ojo, Anthony O; Fond, Benoit; Abram, Christopher; Van Wachem, Berend G M; Heyes, Andrew L; Beyrau, Frank

    2017-05-15

    Simultaneous point measurements of gas velocity and temperature were recently demonstrated using thermographic phosphors as tracer particles. There, continuous wave (CW) excitation was used and the spectral shift of the luminescence was detected with a two-colour intensity ratio method to determine the gas temperature. The conventional laser Doppler velocimetry (LDV) technique was employed for velocimetry. In this paper, an alternative approach to the gas temperature measurements is presented, which is instead based on the temperature-dependence of the luminescence lifetime. The phase-shift between the luminescence signal and time-modulated excitation light is evaluated for single BaMgAl10O17:Eu(2+) phosphor particles as they cross the probe volume. Luminescence lifetimes evaluated in the time domain and frequency domain indicate that in these experiments, interferences from in-phase signals such as stray excitation laser light are negligible. The dependence of the phase-shift on flow temperature is characterised. In the temperature sensitive range above 700 K, precise gas temperature measurements can be obtained (8.6 K at 840 K) with this approach.

  5. Sub-Doppler temperature measurements of laser-cooled atoms using optical nanofibres

    Science.gov (United States)

    Russell, Laura; Deasy, Kieran; Daly, Mark J.; Morrissey, Michael J.; Chormaic, Síle Nic

    2012-01-01

    We present a method for measuring the average temperature of a cloud of cold 85Rb atoms in a magneto-optical trap using an optical nanofibre. A periodic spatial variation is applied to the magnetic fields generated by the trapping coils and this causes the trap centre to oscillate, which, in turn, causes the cloud of cold atoms to oscillate. The optical nanofibre is used to collect the fluorescence emitted by the cold atoms, and the frequency response between the motion of the centre of the oscillating trap and the cloud of atoms is determined. This allows us to make measurements of cloud temperature both above and below the Doppler limit, thereby paving the way for nanofibres to be integrated with ultracold atoms for hybrid quantum devices.

  6. Fiber-optic laser-Doppler anemometer microscope developed for the measurement of microvascular red cell velocity.

    Science.gov (United States)

    Seki, J

    1990-11-01

    A fiber-optic laser-Doppler anemometer microscope (FLDAM) was developed and its applicability to the study of microvascular blood flow was examined by measuring red cell velocities in vivo and in vitro. The FLDAM consists of an intravital microscope equipped with a fringe-mode back-scatter LDA. A data processing method of the Doppler signal which used frequency averaging over the entire frequency range of the power spectrum was developed. Spatial resolution of the FLDAM varied from 17 to 200 microns with 50X to 5X objectives. In vitro experiments showed that the red cell velocity obtained by the FLDAM was equal to the mean flow velocity, within the accuracy of the measurements, for tube diameters from 35 to 100 microns, mean velocity from 0.7 to 17 mm/sec, and feed hematocrit of 20%, when 10X or 20X objectives were used. In vivo red cell velocity measurements conducted with the FLDAM in microvessels of rat mesentery with diameters from 6.5 to 49 microns showed that red cell velocities were about 1/1.6 times smaller than those obtained by the two-slit technique, which also suggests that the velocity obtained by the FLDAM corresponds to the mean flow velocity. This relationship was also established from theoretical considerations for the case where the FLDAM sampling volume covers the entire vessel cross section. Furthermore the frequency response of the FLDAM was established to be about 20 Hz, which was sufficient for measurement of pulsatile velocities in rat mesenteric microvessels.

  7. Physical model experiment for wave field measurements by means of laser Doppler vibrometer. Measurement of three components; Laser Doppler shindokei ni yoru butsuri model jikken. Hado sanseibun no kenshutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, O.; Sato, T. [Geological Survey of Japan, Tsukuba (Japan); Lei, X. [DIA Consultant Co. Ltd., Tokyo (Japan)

    1997-05-27

    In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided probing method. For the study of seismic wave propagation in a complicated three-dimensional ground structure, a numerical model is not enough, and a physical model experiment will be an effective method to fulfill the purpose. In the monitoring of cracks in a rock, again, not only elastic wave velocity but also waveform information collected from a physical model experiment should be fully utilized. 6 refs., 6 figs.

  8. Measurement of a jet issuing from a circular pipe with a laser doppler velocimeter. Laser ryusokukei ni yoru enkan kara no funryu no keisoku

    Energy Technology Data Exchange (ETDEWEB)

    Kita, Y.; Kitamura, Y.; Yamamoto, K. (Okayama Univ., Okayama (Japan). Faculty of Engineering); Yoshinaga, K. (Daikin Industries, Ltd., Osaka (Japan)); Hirose, K. (Okayama University of Science, Okayama (Japan))

    1991-11-25

    In case that the liquid jet issues under gravity from a vertical circular pipe into the atmosphere, the present research investigated the aspect of jet prior to forming the flapping free surface with droplets and then, measured the flow rate, by a laser Doppler velocimeter, in the jet immediately before and after its issuing. Thus, the jet surface profile and change in flowing condition were demonstrated to be relatively expressible by the three dimensionless numbers, i.e., Reynolds, Froude and Weber numbers. The experimental unit forms a circulating loop of lower water tank to pump to main water tank to valve to sub water tank (fitted with an air valve) to acrylic pipe (1m in length, and 8, 12 and 16mm in diameter) to laser probe to lower water tank. The outlet of acrylic pipe is contracted to 30{degree} and opened in the lower water tank. As liquid, used were water, aqueous solution of glyceline and kerosene. As an experimental result, the in-pipe flow also properly maintain its characteristics for the Poiseuille velocity distribution in the flowing region from approximately 12mm in diameter to the issuing extremity in the vicinity of outlet. The other different particulars are also expressible by the above three dimensionless numbers. 4 refs., 13 figs.

  9. A near infrared laser frequency comb for high precision Doppler planet surveys

    Directory of Open Access Journals (Sweden)

    Bally J.

    2011-07-01

    Full Text Available Perhaps the most exciting area of astronomical research today is the study of exoplanets and exoplanetary systems, engaging the imagination not just of the astronomical community, but of the general population. Astronomical instrumentation has matured to the level where it is possible to detect terrestrial planets orbiting distant stars via radial velocity (RV measurements, with the most stable visible light spectrographs reporting RV results the order of 1 m/s. This, however, is an order of magnitude away from the precision needed to detect an Earth analog orbiting a star such as our sun, the Holy Grail of these efforts. By performing these observations in near infrared (NIR there is the potential to simplify the search for distant terrestrial planets by studying cooler, less massive, much more numerous class M stars, with a tighter habitable zone and correspondingly larger RV signal. This NIR advantage is undone by the lack of a suitable high precision, high stability wavelength standard, limiting NIR RV measurements to tens or hundreds of m/s [1, 2]. With the improved spectroscopic precision provided by a laser frequency comb based wavelength reference producing a set of bright, densely and uniformly spaced lines, it will be possible to achieve up to two orders of magnitude improvement in RV precision, limited only by the precision and sensitivity of existing spectrographs, enabling the observation of Earth analogs through RV measurements. We discuss the laser frequency comb as an astronomical wavelength reference, and describe progress towards a near infrared laser frequency comb at the National Institute of Standards and Technology and at the University of Colorado where we are operating a laser frequency comb suitable for use with a high resolution H band astronomical spectrograph.

  10. Laser-Doppler velocimeter measurements in a cascade of controlled diffusion compressor blades at stall

    OpenAIRE

    Ganaim Rickel, Humberto Javier

    1994-01-01

    Approved for public release, distribution unlimited An incipient compressor blade stall has been generated and examined in the Low Speed Cascade Wind Tunnel at the Turbopropulsion Laboratory. The test blades were a controlled-diffusion design with solidity 1.67, and stalling occurred at 10 degrees of incidence above the design inlet air angle. Tufting and laser-sheet flow-visualization techniques showed that the stalling process was unsteady, and occurred over the whole cascade of 20 blade...

  11. Time dependent Doppler shifts in high-order harmonic generation in intense laser interactions with solid density plasma and frequency chirped pulses

    Energy Technology Data Exchange (ETDEWEB)

    Welch, E. C.; Zhang, P.; He, Z.-H. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan 48109-2104 (United States); Dollar, F. [JILA, University of Colorado, Boulder, Colorado 80309 (United States); Krushelnick, K.; Thomas, A. G. R., E-mail: agrt@umich.edu [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan 48109-2104 (United States); Center for Ultrafast Optical Science, University of Michigan, Ann Arbor, Michigan 48109-2104 (United States)

    2015-05-15

    High order harmonic generation from solid targets is a compelling route to generating intense attosecond or even zeptosecond pulses. However, the effects of ion motion on the generation of harmonics have only recently started to be considered. Here, we study the effects of ion motion in harmonics production at ultrahigh laser intensities interacting with solid density plasma. Using particle-in-cell simulations, we find that there is an optimum density for harmonic production that depends on laser intensity, which scales linearly with a{sub 0} with no ion motion but with a reduced scaling if ion motion is included. We derive a scaling for this optimum density with ion motion and also find that the background ion motion induces Doppler red-shifts in the harmonic structures of the reflected pulse. The temporal structure of the Doppler shifts is correlated to the envelope of the incident laser pulse. We demonstrate that by introducing a frequency chirp in the incident pulse we are able to eliminate these Doppler shifts almost completely.

  12. O2C Laser Doppler and Digital Photo Analysis for Treatment Evaluation of Beta-Glucan versus Provitamin Pantothenic Acid of Facial Burns.

    Science.gov (United States)

    Thieme, Daniel; Spilker, Gerald; Lefering, Rolf; Weinand, Christian

    2016-04-01

    Various creams are available for superficial second-degree burns (SSDB) of the face. We evaluated provitamin pantothenic acid versus β-glucan for SSDB of the face using the O2C laser Doppler system and digital photo analysis. Out of 20 patients (January to December 2012) with facial burns, 7 with SSDB of both cheeks were included to our study. Burned cheek wounds were treated using pantothenic acid or β-glucan. Digital photos of marked regions were taken daily from predefined distances. Microcirculation was measured at marked regions for 7 days at scheduled time points using the O2C laser Doppler. Data were evaluated using the SPSS program (SPSS Inc., Chicago, IL). Wounds treated with β-glucan showed faster reepithelialization. O2C laser Doppler measurements showed faster increase in SO2, microvascular perfusion, hemoglobin content, and blood flow. This correlated good with clinical Vancouver Scar Scale results. Although not statistically significant, β-glucan cream therapy of SSDB results in aesthetically superior outcome and faster reepithelialization. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Acute Effects of Vascular Modifying Agents in Solid Tumors Assessed by Noninvasive Laser Doppler Flowmetry and Near Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Michael Kragh

    2002-01-01

    Full Text Available The potential of noninvasive laser Doppler flowmetry (LDF and near infrared spectroscopy (NIRS to detect acute effects of different vascular-modifying agents on perfusion and blood volume in tumors was evaluated. C3H mouse mammary carcinomas (∼200 mm3 in the rear foot of CDF1 mice were treated with flavone acetic acid (FAA, 150 mg/kg, 5,6-dimethylxanthenone-4acetic acid (DMXAA, 20 mg/kg, combretastatin A-4 disodium phosphate (CAMP, 250 mg/kg, hydralazine (HDZ, 5 mg/kg, or nicotinamide (NTA, 500 mg/kg. Tumor perfusion before and after treatment was evaluated by noninvasive LDF, using a 41°C heated custombuilt LDF probe with four integrated laser/receiver units, and tumor blood volume was estimated by MRS, using light guide coupled reflectance measurements at 800±10 nm. FAA, DMXAA, CAMP, and HDZ significantly decreased tumor perfusion by 50%, 47%, 73%, and 78%, respectively. In addition, FAA, DMXAA, and HDZ significantly reduced the blood volume within the tumor, indicating that these compounds to some degree shunted blood from the tumor to adjacent tissue, HDZ being most potent. CAMP caused no change in the tumor blood volume, indicating that the mechanism of action of CAMP was vascular shut down with the blood pool trapped in the tumor. NTA caused no change in either tumor perfusion or tumor blood volume. We conclude that noninvasive LDF and MRS can determine acute effects of vascular modifying agents on tumor perfusion and blood volume.

  14. Compact Laser Doppler Flowmeter (LDF Fundus Camera for the Assessment of Retinal Blood Perfusion in Small Animals.

    Directory of Open Access Journals (Sweden)

    Marielle Mentek

    Full Text Available Noninvasive techniques for ocular blood perfusion assessment are of crucial importance for exploring microvascular alterations related to systemic and ocular diseases. However, few techniques adapted to rodents are available and most are invasive or not specifically focused on the optic nerve head (ONH, choroid or retinal circulation. Here we present the results obtained with a new rodent-adapted compact fundus camera based on laser Doppler flowmetry (LDF.A confocal miniature flowmeter was fixed to a specially designed 3D rotating mechanical arm and adjusted on a rodent stereotaxic table in order to accurately point the laser beam at the retinal region of interest. The linearity of the LDF measurements was assessed using a rotating Teflon wheel and a flow of microspheres in a glass capillary. In vivo reproducibility was assessed in Wistar rats with repeated measurements (inter-session and inter-day of retinal arteries and ONH blood velocity in six and ten rats, respectively. These parameters were also recorded during an acute intraocular pressure increase to 150 mmHg and after heart arrest (n = 5 rats.The perfusion measurements showed perfect linearity between LDF velocity and Teflon wheel or microsphere speed. Intraclass correlation coefficients for retinal arteries and ONH velocity (0.82 and 0.86, respectively indicated strong inter-session repeatability and stability. Inter-day reproducibility was good (0.79 and 0.7, respectively. Upon ocular blood flow cessation, the retinal artery velocity signal substantially decreased, whereas the ONH signal did not significantly vary, suggesting that it could mostly be attributed to tissue light scattering.We have demonstrated that, while not adapted for ONH blood perfusion assessment, this device allows pertinent, stable and repeatable measurements of retinal blood perfusion in rats.

  15. Non-contact measurement of tremor for the characterisation of Parkinsonian individuals: comparison between Kinect and Laser Doppler vibrometer

    Science.gov (United States)

    Casacanditella, L.; Cosoli, G.; Ceravolo, MG; Tomasini, EP

    2017-08-01

    Parkinson’s disease is a progressive neurodegenerative disorder affecting the central nervous system. One of its main and most evident symptoms is the tremor, which usually manifests at rest with varying intensity during time. An important diagnostic challenge is the differential diagnosis between Parkinson’s disease and the other most widely represented tremor syndrome, i.e. Essential (or senile) tremor. At present there are no standard methods for the quantification of tremor and the diagnosis of both Parkinson’s disease and Essential tremor is mainly done on the base of clinical criteria and by using rating scales. The aim of this work is to objectively and non-invasively assess the tremor linked to the quoted diseases, using non-contact techniques: Laser Doppler Vibrometer (LDV) and Kinect for Windows device. Two subjects with Parkinson’s disease and one with Essential tremor were tested in different conditions: at rest, during a cognitive task, with forward stretched arms and in “Wing position”. The results from data processing in terms of tremor frequency seem to be comparable, with a mean deviation of 0.31 Hz. Furthermore, the values computed are consistent with what is stated in the literature (i.e. 4-12 Hz). So, both LDV and Kinect device can be considered suitable to be used as an objective means for the assessment and monitoring of Parkinson’s disease tremor, helping the clinician in the choice of the most suitable treatment for the patients.

  16. Ultrasound assessed thickness of burn scars in association with laser Doppler imaging determined depth of burns in paediatric patients.

    Science.gov (United States)

    Wang, Xue-Qing; Mill, Julie; Kravchuk, Olena; Kimble, Roy M

    2010-12-01

    This study describes the ultrasound assessment of burn scars in paediatric patients and the association of these scar thickness with laser Doppler imaging (LDI) determined burn depth. A total of 60 ultrasound scar assessments were conducted on 33 scars from 21 paediatric burn patients at 3, 6 and 9 months after-burn. The mean of peak scar thickness was 0.39±0.032 cm, with the thickest at 6 months (0.40±0.036 cm). There were 17 scald burn scars (0.34±0.045 cm), 4 contact burn scars (0.61±0.092 cm), and 10 flame burn scars (0.42±0.058 cm). Each group of scars followed normal distributions. Twenty-three scars had original burns successfully scanned by LDI and various depths of burns were presented by different colours according to blood perfusion units (PU), with dark blue burns, with the thinnest scars for green coloured burns and the thickest for dark blue coloured burns. Within light blue burns, grafted burns healed with significantly thinner scars than non-grafted burns. This study indicates that LDI can be used for predicting the risk of hypertrophic scarring and for guiding burn care. To our knowledge, this is the first study to correlate the thickness of burns scars by ultrasound scan with burn depth determined by LDI.

  17. Continuous measurement of cerebral cortical blood flow by laser-Doppler flowmetry in a rat stroke model

    Energy Technology Data Exchange (ETDEWEB)

    Dirnagl, U.; Kaplan, B.; Jacewicz, M.; Pulsinelli, W. (Cornell Univ. Medical College, New York, NY (USA))

    1989-10-01

    Laser-Doppler flowmetry (LDF), a new method allowing instantaneous, continuous, and noninvasive measurements of microcirculatory blood flow in a small tissue sample, was evaluated for its accuracy in monitoring regional cerebral blood flow (rCBF) in the cortical microcirculation after focal cerebral ischemia. Wistar and spontaneously hypertensive rats (SHR, n = 19) were subjected to permanent occlusion of the middle cerebral and common carotid arteries. Absolute rCBF in a tissue sample of the ischemic hemisphere was measured autoradiographically with ({sup 14}C)iodoantipyrine as a tracer and compared to rCBF measured by LDF. Additionally, the percent change in rCBF between baseline and ischemic values was compared for both methods. Absolute rCBF values recorded with LDF correlated poorly (r = 0.54) with ({sup 14}C)iodoantipyrine measurements. In contrast LDF readings expressed as a percentage of ischemic vs. preocclusion readings (relative LDF readings) correlated very well (r = 0.91) with the percent change in (14C)iodoantipyrine measurements. We conclude that LDF does not provide accurate measurements of absolute rCBF values but this method allows accurate measurements of changes in rCBF due to induction of focal cerebral ischemia.

  18. Continuous measurement of cerebral cortical blood flow by laser-Doppler flowmetry in a rat stroke model.

    Science.gov (United States)

    Dirnagl, U; Kaplan, B; Jacewicz, M; Pulsinelli, W

    1989-10-01

    Laser-Doppler flowmetry (LDF), a new method allowing instantaneous, continuous, and noninvasive measurements of microcirculatory blood flow in a small tissue sample, was evaluated for its accuracy in monitoring regional cerebral blood flow (rCBF) in the cortical microcirculation after focal cerebral ischemia. Wistar and spontaneously hypertensive rats (SHR, n = 19) were subjected to permanent occlusion of the middle cerebral and common carotid arteries. Absolute rCBF in a tissue sample of the ischemic hemisphere was measured autoradiographically with [14C]iodoantipyrine as a tracer and compared to rCBF measured by LDF. Additionally, the percent change in rCBF between baseline and ischemic values was compared for both methods. Absolute rCBF values recorded with LDF correlated poorly (r = 0.54) with [14C]iodoantipyrine measurements. In contrast LDF readings expressed as a percentage of ischemic vs. preocclusion readings (relative LDF readings) correlated very well (r = 0.91) with the percent change in [14C]iodoantipyrine measurements. We conclude that LDF does not provide accurate measurements of absolute rCBF values but this method allows accurate measurements of changes in rCBF due to induction of focal cerebral ischemia.

  19. Multifractal analysis of heart rate variability and laser Doppler flowmetry fluctuations:comparison of results from different numerical methods

    Energy Technology Data Exchange (ETDEWEB)

    Humeau, Anne; Buard, Benjamin; Chapeau-Blondeau, Francois; Rousseau, David [Laboratoire d' Ingenierie des Systemes Automatises (LISA), Universite d' Angers, 62 avenue Notre Dame du Lac, 49000 Angers (France); Mahe, Guillaume; Abraham, Pierre, E-mail: anne.humeau@univ-angers.f [Laboratoire de Physiologie et d' Explorations Vasculaires, UMR CNRS 6214-INSERM 771, Centre Hospitalier Universitaire d' Angers, 49033 Angers cedex 01 (France)

    2010-10-21

    To contribute to the understanding of the complex dynamics in the cardiovascular system (CVS), the central CVS has previously been analyzed through multifractal analyses of heart rate variability (HRV) signals that were shown to bring useful contributions. Similar approaches for the peripheral CVS through the analysis of laser Doppler flowmetry (LDF) signals are comparatively very recent. In this direction, we propose here a study of the peripheral CVS through a multifractal analysis of LDF fluctuations, together with a comparison of the results with those obtained on HRV fluctuations simultaneously recorded. To perform these investigations concerning the biophysics of the CVS, first we have to address the problem of selecting a suitable methodology for multifractal analysis, allowing us to extract meaningful interpretations on biophysical signals. For this purpose, we test four existing methodologies of multifractal analysis. We also present a comparison of their applicability and interpretability when implemented on both simulated multifractal signals of reference and on experimental signals from the CVS. One essential outcome of the study is that the multifractal properties observed from both the LDF fluctuations (peripheral CVS) and the HRV fluctuations (central CVS) appear very close and similar over the studied range of scales relevant to physiology.

  20. Multifractal analysis of heart rate variability and laser Doppler flowmetry fluctuations:comparison of results from different numerical methods

    Science.gov (United States)

    Humeau, Anne; Buard, Benjamin; Mahé, Guillaume; Chapeau-Blondeau, François; Rousseau, David; Abraham, Pierre

    2010-10-01

    To contribute to the understanding of the complex dynamics in the cardiovascular system (CVS), the central CVS has previously been analyzed through multifractal analyses of heart rate variability (HRV) signals that were shown to bring useful contributions. Similar approaches for the peripheral CVS through the analysis of laser Doppler flowmetry (LDF) signals are comparatively very recent. In this direction, we propose here a study of the peripheral CVS through a multifractal analysis of LDF fluctuations, together with a comparison of the results with those obtained on HRV fluctuations simultaneously recorded. To perform these investigations concerning the biophysics of the CVS, first we have to address the problem of selecting a suitable methodology for multifractal analysis, allowing us to extract meaningful interpretations on biophysical signals. For this purpose, we test four existing methodologies of multifractal analysis. We also present a comparison of their applicability and interpretability when implemented on both simulated multifractal signals of reference and on experimental signals from the CVS. One essential outcome of the study is that the multifractal properties observed from both the LDF fluctuations (peripheral CVS) and the HRV fluctuations (central CVS) appear very close and similar over the studied range of scales relevant to physiology.

  1. Comparison of velocity measurements by high temperature anemometer and laser-doppler anemometer with results of CFD-simulation

    Directory of Open Access Journals (Sweden)

    Zimmel M.

    2002-01-01

    Full Text Available In the present work, results of gas velocity measurements with a newly developed vane anemometer (HTA - High Tem per a ture Anemometer are compared with re sults of measurements obtained from Laser-Doppler Anemometer (LDA. The measurements were carried out at the combustion test rig of ALSTOM Combustion Services Ltd. in Derby/UK, and demonstrate the usability and accuracy of the HTA under severe conditions. The test rig was provided with a triple register low NOx coal burner firing pulverised Colombian blended coal at a constant thermal load of 30 MW. Although the environment was both very hot (up to 1350 °C and dust laden, the vane anemometer worked with an accuracy comparable to the reference LDA measurement. Since the anemometer represents a relatively simple to use and low cost option compared with LDA, it is seen as aviable alternative for gas velocity measurements in difficult environments. The measurement results are also demonstrated to compare favourably with the results from CFD calculations of the flow in the combustion chamber of the test rig.

  2. Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter

    Directory of Open Access Journals (Sweden)

    Wataru Iwasaki

    2015-10-01

    Full Text Available Wearable wireless physiological sensors are helpful for monitoring and maintaining human health. Blood flow contains abundant physiological information but it is hard to measure blood flow during exercise using conventional blood flowmeters because of their size, weight, and use of optic fibers. To resolve these disadvantages, we previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems technology. This micro blood flowmeter is wearable and capable of stable measurement signals even during movement. Therefore, we attempted to measure skin blood flow at the forehead, fingertip, and earlobe of seven young men while running as a pilot experiment to extend the utility of the micro blood flowmeter. We measured blood flow in each subject at velocities of 6, 8, and 10 km/h. We succeeded in obtaining stable measurements of blood flow, with few motion artifacts, using the micro blood flowmeter, and the pulse wave signal and motion artifacts were clearly separated by conducting frequency analysis. Furthermore, the results showed that the extent of the changes in blood flow depended on the intensity of exercise as well as previous work with an ergometer. Thus, we demonstrated the capability of this wearable blood flow sensor for measurement during exercise.

  3. Repeatability, Reproducibility and Standardisation of a Laser Doppler Imaging Technique for the Evaluation of Normal Mouse Hindlimb Perfusion

    Directory of Open Access Journals (Sweden)

    Arturo Brunetti

    2012-12-01

    Full Text Available Background. Preclinical perfusion studies are useful for the improvement of diagnosis and therapy in dermatologic, cardiovascular and rheumatic human diseases. The Laser Doppler Perfusion Imaging (LDPI technique has been used to evaluate superficial alterations of the skin microcirculation in surgically induced murine hindlimb ischemia. We assessed the reproducibility and the accuracy of LDPI acquisitions and identified several critical factors that could affect LDPI measurements in mice. Methods. Twenty mice were analysed. Statistical standardisation and a repeatability and reproducibility analysis were performed on mouse perfusion signals with respect to differences in body temperature, the presence or absence of hair, the type of anaesthesia used for LDPI measurements and the position of the mouse body. Results. We found excellent correlations among measurements made by the same operator (i.e., repeatability under the same experimental conditions and by two different operators (i.e., reproducibility. A Bland-Altman analysis showed the absence of bias in repeatability (p = 0.29 or reproducibility (p = 0.89. The limits of agreement for repeatability were –0.357 and –0.033, and for reproducibility, they were –0.270 and 0.238. Significant differences in perfusion values were observed in different experimental groups. Conclusions. Different experimental conditions must be considered as a starting point for the evaluation of new drugs and strategic therapies.

  4. Guided-wave-based damage detection in a composite T-joint using 3D scanning laser Doppler vibrometer

    Science.gov (United States)

    Kolappan Geetha, Ganesh; Roy Mahapatra, D.; Srinivasan, Gopalakrishnan

    2012-04-01

    Composite T-joints are commonly used in modern composite airframe, pressure vessels and piping structures, mainly to increase the bending strength of the joint and prevents buckling of plates and shells, and in multi-cell thin-walled structures. Here we report a detailed study on the propagation of guided ultrasonic wave modes in a composite T-joint and their interactions with delamination in the co-cured co-bonded flange. A well designed guiding path is employed wherein the waves undergo a two step mode conversion process, one is due to the web and joint filler on the back face of the flange and the other is due to the delamination edges close to underneath the accessible surface of the flange. A 3D Laser Doppler Vibrometer is used to obtain the three components of surface displacements/velocities of the accessible face of the flange of the T-joint. The waves are launched by a piezo ceramic wafer bonded on to the back surface of the flange. What is novel in the proposed method is that the location of any change in material/geometric properties can be traced by computing a frequency domain power flow along a scan line. The scan line can be chosen over a grid either during scan or during post-processing of the scan data off-line. The proposed technique eliminates the necessity of baseline data and disassembly of structure for structural interrogation.

  5. Laser Echosclerotherapy of varicose veins with haemodynamic echo-doppler evaluation : some rationale and short-term outcomes

    Science.gov (United States)

    Vettorello, Gianfranco; Marini, Leonardo

    2009-06-01

    Purpose: The aim is to verify short-term results in Endovenous Laser Treatment (EVLT) performed in haemodynamic way in patients belonging to C2, C3 classes and type I, II, III venous shunts, according respectively with CEAP and Teupitz classification. Methods: Minor changes of technique were applied to EVLT in order to provide haemodynamic conditions. Treatment efficacy, anatomical failure, complications, recurrence rate and clinical improvements were analyzed. 105 limbs were treated from November 2004 to November 2007. Clinical and Echo-Colour-Doppler (ECD) follow up was performed two weeks, one, two and three years after the surgery. Results: in 79 inferior limbs follow-up was concluded and this are the final data: a) no Deep Venous Thrombosis (DVT) was detected; b) a notable reduction of recurrence if compared with groin recurrence rate in traditional stripping; e) satisfactory cosmetic results and short recovery were found in all the patients. Conclusions: In selected patients haemodynamic-guided EVLT is equally safe and efficient than standard. Clinical and aesthetical outcomes are durable without statistical differences on the plan of disease progression and complications. The recurrence rate is lower in EVLT haemodynamic-guided surgery than in conventional stripping. Long-term outcomes should be investigated. We need studies camparison among the three different kind of surgery performed in haemodynamic way

  6. A novel laser-Doppler flowmetry assisted murine model of acute hindlimb ischemia-reperfusion for free flap research.

    Directory of Open Access Journals (Sweden)

    Tolga Taha Sönmez

    Full Text Available Suitable and reproducible experimental models of translational research in reconstructive surgery that allow in-vivo investigation of diverse molecular and cellular mechanisms are still limited. To this end we created a novel murine model of acute hindlimb ischemia-reperfusion to mimic a microsurgical free flap procedure. Thirty-six C57BL6 mice (n = 6/group were assigned to one control and five experimental groups (subject to 6, 12, 96, 120 hours and 14 days of reperfusion, respectively following 4 hours of complete hindlimb ischemia. Ischemia and reperfusion were monitored using Laser-Doppler Flowmetry. Hindlimb tissue components (skin and muscle were investigated using histopathology, quantitative immunohistochemistry and immunofluorescence. Despite massive initial tissue damage induced by ischemia-reperfusion injury, the structure of the skin component was restored after 96 hours. During the same time, muscle cells were replaced by young myotubes. In addition, initial neuromuscular dysfunction, edema and swelling resolved by day 4. After two weeks, no functional or neuromuscular deficits were detectable. Furthermore, upregulation of VEGF and tissue infiltration with CD34-positive stem cells led to new capillary formation, which peaked with significantly higher values after two weeks. These data indicate that our model is suitable to investigate cellular and molecular tissue alterations from ischemia-reperfusion such as occur during free flap procedures.

  7. Calibrating airborne measurements of airspeed, pressure and temperature using a Doppler laser air-motion sensor

    Directory of Open Access Journals (Sweden)

    W. A. Cooper

    2014-09-01

    Full Text Available A new laser air-motion sensor measures the true airspeed with a standard uncertainty of less than 0.1 m s−1 and so reduces uncertainty in the measured component of the relative wind along the longitudinal axis of the aircraft to about the same level. The calculated pressure expected from that airspeed at the inlet of a pitot tube then provides a basis for calibrating the measurements of dynamic and static pressure, reducing standard uncertainty in those measurements to less than 0.3 hPa and the precision applicable to steady flight conditions to about 0.1 hPa. These improved measurements of pressure, combined with high-resolution measurements of geometric altitude from the global positioning system, then indicate (via integrations of the hydrostatic equation during climbs and descents that the offset and uncertainty in temperature measurement for one research aircraft are +0.3 ± 0.3 °C. For airspeed, pressure and temperature, these are significant reductions in uncertainty vs. those obtained from calibrations using standard techniques. Finally, it is shown that although the initial calibration of the measured static and dynamic pressures requires a measured temperature, once calibrated these measured pressures and the measurement of airspeed from the new laser air-motion sensor provide a measurement of temperature that does not depend on any other temperature sensor.

  8. 激光多普勒效应实验仪的设计%The Design of Experiment Instrument of Laser Doppler Effect

    Institute of Scientific and Technical Information of China (English)

    郝建华; 孙华燕

    2001-01-01

    为了解决激光多普勒效应在实验室演示比较困难问题,介绍了一种采用双光栅法实现激光多普勒效应的实验仪器,分析了双光栅法多普勒效应原理,给出了该仪器的组成结构,并分析了该仪器的特点。实验表明:采用双光栅法实现激光多普勒效应操作简单、效果明显。%In order to solve the problem that laser Doppler effect is difficult to demonstrate in laboratory. The paper introduces a kind of experiment instrument of laser Doppler effect based on double grating .The double grating principle of Doppler effect and constitute frame of experiment instrument are analyzed . The characteristics of the experiment instrument are also present . Experiments show it is easy to manipulate and the effectiveness is obvious in this way.

  9. A solid state laser system for Doppler-free spectroscopy of muonium

    CERN Document Server

    Bakule, P

    1998-01-01

    to 1MHz, was found to be of the order of 80-120 MHz for a 30-40 mJ output. This chirp was shown to be the result of a fast change of the refractive index in the alexandrite rods, and was found to be directly proportional to the population inversion change during the Q-switched pulse. A method of chirp compensation was developed leading to a reduction of the chirp by an order of magnitude i.e. to the level of 5-15 MHz. The alexandrite output was frequency tripled using LBO and BBO crystals with a conversion efficiency in excess of 10 %, yielding UV pulse energies of 3 to 6 mJ. The 1S-2S transition frequency has been measured to be 2,455,528,940.99 (9.75)(3.5) MHz which is in agreement with the theoretical value of 2,455,528,934.61 (3.44) MHz. Measurement of 1S-2S interval in deuterium, performed primarily to study systematic errors, represents the best pulsed measurement to date and is in an agreement with values obtained with cw lasers. The thesis describes a new high precision measurement of the 1S-2S transi...

  10. Analysis of laser speckle contrast images variability using a novel empirical mode decomposition: comparison of results with laser Doppler flowmetry signals variability.

    Science.gov (United States)

    Humeau-Heurtier, Anne; Abraham, Pierre; Mahe, Guillaume

    2015-02-01

    Laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) have emerged as noninvasive optical modalities to monitor microvascular blood flow. Many studies proposed to extract physiological information from LDF by analyzing signals variability. By opposition, such analyses for LSCI data have not been conducted yet. We propose to analyze LSCI variability using a novel data-driven method: the complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN). CEEMDAN is suitable for nonlinear and nonstationary data and leads to intrinsic mode functions (IMFs). It is based on the ensemble empirical mode decomposition (EEMD) which relies on empirical mode decomposition (EMD). In our work the average frequencies of LSCI IMFs given by CEEMDAN are compared with the ones given by EMD and EEMD. Moreover, LDF signals acquired simultaneously to LSCI data are also processed with CEEMDAN, EMD and EEMD. We show that the average frequencies of IMFs given by CEEMDAN depend on the signal-to-noise ratio (SNR) used in the computation but, for a given SNR, the average frequencies found for LSCI are close to the ones obtained for LDF. By opposition, EEMD leads to IMFs with frequencies that do not vary much when the SNR level is higher than a threshold. The new CEEMDAN algorithm has the advantage of achieving a complete decomposition with no error in the reconstruction but our study suggests that further work is needed to gain knowledge in the adjustment of the added noise level. CEEMDAN, EMD and EEMD are data-driven methods that can provide a better knowledge of LSCI.

  11. Nailfold capillaroscopy and blood flow laser-doppler analysis of the microvascular damage in systemic sclerosis: preliminary results

    Directory of Open Access Journals (Sweden)

    C. Pizzorni

    2011-06-01

    Full Text Available Objectives: Systemic sclerosis (SSc is characterized by altered microvascular structure and function. Nailfold videocapillaroscopy (NVC is the tool to evaluate capillary morphological structure and laser-Doppler Blood flowmetry (LDF can be used to estimate cutaneous blood flow of microvessels. The aim of this study was to investigate possible relationships between capillary morphology and blood flow in SSc. Methods: 27 SSc patients and 12 healthy subjects were enrolled. SSc microvascular involvement, as evaluated by NVC, was classified in three different patterns (“Early”, “Active”, “Late”. LDF analysis was performed at the II, III, IV, V hand fingers in both hands and both at cutaneous temperature and at 36°C. Statistical evaluation was carried out by non-parametric procedures. Results: Blood flow was found significantly lower in SSc patients when compared with healthy subjects (p<0.05. The heating of the probe to 36°C induced a significant increase in peripheral blood flow in all subjects compared to baseline (p <0.05, however, the amount of variation was significantly lower in patients with SSc, compared with healthy controls (p <0.05. The SSc patients with NVC “Late” pattern, showed lower values of peripheral blood flow than patients with NVC “Active” or “Early” patterns (p<0.05. Moreover, a negative correlation between the tissue perfusion score and the progression of the SSc microangiopathy was observed, as well as between the tissue perfusion and the duration of the Raynaud’s phenomenon (p <0.03. Conclusions: LDF can be employed to evaluate blood perfusion in the microvascular circulation in SSc patients. The blood flow changes observed with the LDF seem to correlate with the severity of microvascular damage in SSc as detected by NVC.

  12. [Value of combining the thermal test with laser Doppler measurement of skin hemodynamics. Study of vascular acrosyndromes].

    Science.gov (United States)

    Boccalon, H; Marguery, M C; Ginestet, M C; Puel, P

    1987-01-01

    Different exploratory investigations of vascular acrosyndromes have failed to define their physiopathology. Capillaroscopy studies the specific morphologic aspects of certain connective tissue diseases, hemodynamic tests usually determine a global parameter, and those tests investigating cutaneous physiology alone come up against difficulties limiting their diffusion. The laser Doppler flowmeter (LDF) measures global skin flow in a reproducible, continuous simple manner, and was combined with standardized provocation tests during a prospective study to assess its value in angiology. The protocol involved a prospective study of 100 subjects during the winter 1984-1985: 21 healthy volunteers, 11 cases of acrocyanosis, 9 of acrorhigosis, 48 of Raynaud's phenomenon (22 primary and 26 secondary), 11 of connective tissue disease without Raynaud's phenomenon (table I). The LDD test measures skin microcirculation flow continuously in parallel with skin thermometry. Provocation tests included a standardized thermal test (fig. 1); the temperature is automatically reduced to 0 degree C in 15 minutes and then increased to 25 degrees C in 10 minutes in a jar into which the hand and forearm of the patients and any measuring captor are introduced. Respiratory provocation and additional pharmacologic tests were also completed. Interpretation of results involved calculation of the mean skin flow, Dm, pulsatile skin flow, Dp (fig. 2 and 3), at the basal state and then during temperature variations. The reference value of Dm is 2.741 +/- 0.378 V and is decreased in acrorhigosis, acrocyanosis and severe Raynaud's phenomenon. At 0 degrees C the decrease in Dm is 33 +/- 13% in healthy subjects. Specific values for different acrosyndromes and particularly the various types of Raynaud's phenomenon do not exist.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Preliminary study of laser doppler perfusion signal by wavelet transform in patients with critical limb ischemia before and after revascularization.

    Science.gov (United States)

    Ticcinelli, Valentina; Martini, Romeo; Bagno, Andrea

    2014-01-01

    The haemodynamics of skin microcirculation can be quantitatively evaluated by Laser Doppler Fluxmetry (LDF). LDF signal in human skin shows periodic oscillations. Spectral analysis by wavelet transform displays six characteristic frequency intervals (FI) from 0.005 to 2 Hz, related to distinct vascular structures activities: heart (0.6-2 Hz), sympathetic respiratory (0.145-0.6 Hz), myogenic (0.052-0.145 Hz), local sympathetic nerve (0.021-0.052 Hz) and endothelial cells NO dependent (0.0095-0.021 Hz) and NO independent (0.005-0.0095 Hz). The most advanced stage of peripheral arterial obstructive disease is the critical limb ischemia (CLI), which causes the reduction of blood perfusion threatening limb viability. Besides macrocirculatory alterations, many studies have shown microvascular misdistribution of skin blood flow as the main factor that leads patients to CLI. Revascularization can save limb and patient's life, too. In the present study, LDF signals have been recorded on the skin of the foot dorsum in 15 patients suffering from CLI. LDF signals have been analyzed before and after limb revascularization by means of the wavelet analysis. Significant changes in frequency distribution before and after limb revascularization have been detected: the median normalized values of spectral power increases for 49.8% (p = 0.0341) in the frequency range 0.050328-0.053707 Hz, whereas spectral power decreases for 77.1% (p = 0.0179) in the frequency range 0.018988-0.029284 Hz. We can conclude that changes in the frequency intervals occur after revascularization, shifting from a prevailing endothelial activity toward a prevailing sympathetic activity.

  14. Minimizing endoscopic thoracic sympathectomy for primary palmar hyperhidrosis: guided by palmar skin temperature and laser Doppler blood flow.

    Science.gov (United States)

    Li, Xu; Tu, Yuan-Rong; Lin, Min; Lai, Fan-Cai; Chen, Jian-Feng; Miao, Hui-Weng

    2009-02-01

    Limiting the extent of sympathectomy in palmar hyperhidrosis was recently recognized as an effective method to minimize the incidence and severity of troublesome compensatory sweating. However, the levels at which transection should be performed remain controversial. In this study, we proposed that the level of ablation varies and should be adjusted for each individual patient. Guided by palmar skin temperature and laser Doppler blood flow, we try to find the correct target level in each case. Fifty patients with severe primary palmar hyperhidrosis received bilateral endoscopic thoracic sympathectomy. Different levels of transection from T4 to T2 were performed step by step until the successful extirpation was implied by the intraoperative monitoring. The results of the operations were studied. All patients were followed up and evaluated for symptom resolution, postoperative complication, levels of satisfaction, and severity of compensatory sweating. Of a total of 100 lateral procedures, 76 laterals (76%) ended the procedure at the T4 level, 23 laterals (23%) ended the procedure at the T3 level, and 1 lateral (1%) ended the procedure at the T2 level. The postoperative complication was minor, and no Horner's syndrome was detected. The rate of symptom resolution was 100% and no recurrence was found. The satisfaction rate was 92%, and the incidence of mild, moderate, and severe compensatory sweating were 12%, 8%, and 6%, respectively. Concerning the sympathectomy for palmar hyperhidrosis, there is a possibility that the level of the transection varies and should be adjusted for each individual patient. Intraoperative monitoring of temperature and blood flow may be a useful tool in establishing a kind of standardized reference for finding the correct target level.

  15. No effect of 85 mT permanent magnets on laser-Doppler measured blood flow response to inspiratory gasps.

    Science.gov (United States)

    Mayrovitz, Harvey N; Groseclose, Edye E; King, David

    2005-05-01

    Although no effects of permanent magnets on resting skin blood flow (SBF) in humans have yet been demonstrated, the possibility that magnet related effects might modify dynamic SBF changes has not been previously studied. We hypothesized that magnets may alter local neurovascular mechanisms to cause changes in normal SBF vasoactive responses. To test this, we studied the effects of a magnet on SBF reductions induced by sympathetic reflexes associated with deep inspirations. SBF was continuously monitored by a dual channel laser-Doppler flowmeter with probes on the middle finger dorsum of both hands of 24 healthy subjects. In the first of two successive intervals, each of the fingers rested on sham ceramic magnets (control interval). Subsequently, one finger rested on an active magnet and the other finger on a sham (experimental interval). Skin temperatures were also measured. The magnet was a 37 mm diameter x 14 mm thick ceramic magnet with a surface field strength of 85 mT measured in the geometrical center of the magnet. Field strength at the finger dorsum, 13 mm above magnet, was 31.5 mT. During each interval, three deep breaths were used to elicit SBF reductions. Responses were calculated as the percent reduction in SBF from its prior 20 s average. Breaths in each interval were spaced 3 min apart to permit full recovery between responses. The experimental interval started after an active magnet was in place for 20 min. Results showed no significant difference in either vasoconstrictive responses or skin temperature due to the magnet. We conclude that magnets of the type, strength and duration used, have no significant effect on vasoconstrictive processes associated with this sympathetic reflex in this group of healthy subjects.

  16. Flow visualization and 1- and 3-D laser-Doppler-anemometer measurements in models of human carotid arteries.

    Science.gov (United States)

    Liepsch, D; Pflugbeil, G; Matsuo, T; Lesniak, B

    1998-04-01

    Pulsatile flow, wall distensibility, non-Newtonian flow characteristics of blood in flow separation regions, and high/low blood pressure were studied in elastic silicon rubber models having a compliance similar to human vessels and the same surface structure as the biological intima models of (1) a healthy carotid artery model, (2) a 90% stenosis in the ICA, and (3) 80% stenosis in both the internal and external carotid arteries. Flow was visualized for steady flow and pulsatile studies to localize flow separation regions and reattachment points. Local velocity was measured with a 1-, 2-, or 3-D laser-Doppler-anemometer (LDA). Flow in the unstenosed model was Re = 250. In the stenosed models, the Re number decreased to Re = 180 and 213 under the same experimental conditions. High velocity fluctuations with vortices were found in the stenosed models. The jet flow in the stenosis increased up to 4 m/s. With an increasing bifurcation angle, the separation regions in the ECA and ICA increased. Increased flow (Re = 350) led to an increase in flow separation and high velocity shear gradients. The highest shear stresses were nearly 20 times higher than normal. The 90% stenosis created high velocity shear gradients and velocity fluctuations. Downstream of the stenoses, eddies were found over the whole cross-section. In the healthy model a slight flow separation region was observed in the ICA at the branching cross-section whereas in the stenosed models, the flow separation regions extended far into the ICA. We conclude that a detailed understanding of flow is necessary before vascular surgery is performed especially before artificial grafts or patches are implanted.

  17. Prostaglandin E1 Increases Microcirculation in Random Pattern Flaps on Rats Measured with Laser Doppler Perfusion Imaging

    Science.gov (United States)

    Sneistrup, Christian; Berg, Thomas Moe

    2017-01-01

    Background: Reconstructive procedures with pedicled and free flaps are associated with a risk of ischemia. Prostaglandin E1 (PGE1) is a hormone-like substance with known antiischemic and tissue-protective effects. The aim of this study was to evaluate the effect of PGE1 on the microcirculation in random pattern skin flaps on rats. Methods: Twenty-four rats were divided into 2 groups: an intervention group given PGE1 for 6 hours and a control group given saline. The flap (2 × 10 cm) was created on the back of the rats, and the microcirculation was monitored with laser Doppler perfusion imaging in 5 different zones (1, proximal; 5, distal) before surgery and after 60, 180, and 360 minutes postoperatively. Results: Before surgery, there was no difference in the perfusion in any zones between the intervention group and the control group. The mean perfusion values in zone 1 in the intervention group were significantly higher than those in the control group at 60, 180, and 360 minutes postoperatively (P = 0.02, P = 0.05, and P = 0.04, respectively). At 360 minutes, we also found significantly higher levels of perfusion in the intervention group in zones 4 and 5 (P = 0.05 and P = 0.03, respectively) compared with the controls. Comparing the perfusion at 360 to 60 minutes in the intervention group, we found a significant increase in microcirculation in all zones, which were not seen in the control group. Conclusion: PGE1 increased perfusion in the dermal random pattern flaps on rats. PMID:28203503

  18. Effect of Endolymphatic Hydrops on Sound Transmission in Live Guinea Pigs Measured with a Laser Doppler Vibrometer.

    Science.gov (United States)

    Ding, Chen-Ru; Xu, Xin-Da; Wang, Xin-Wei; Jia, Xian-Hao; Cheng, Xiang; Liu, Xiang; Yang, Lin; Tong, Bu-Sheng; Chi, Fang-Lu; Ren, Dong-Dong

    2016-01-01

    Objective. This study aimed at describing the mechanism of hearing loss in low frequency and the different dynamic behavior of the umbo, the stapes head, and the round window membrane (RWM) between normal guinea pigs and those with endolymphatic hydrops (EH), using a laser Doppler vibrometer (LDV). Methods. Cochlear sections were stained with hematoxylin and eosin (HE) to evaluate the hydropic ratio (HR). Auditory brainstem responses (ABR) and whole-mount immunostaining were measured. Displacement of the umbo, stapes head, and RWM in response to ear-canal sound was evaluated using a LDV. Results. Mean HR values in EH model of all the turns are larger than the control group. The ABR threshold of the EH group was significantly higher than that of the control. Strong positive correlation was found between HR at apical turn and ABR threshold elevation at 1000 Hz and at subapical turn and ABR threshold elevation at 2000 Hz. FITC-phalloidin immunostaining of the cochlear basilar membrane in the apical, subapical, and suprabasal turns showed missing and derangement stereocilia of third-row outer hair cells. The umbo, stapes head, and RWM displacement in ears with EH was generally lower than that of normal ears. The EH-induced differences in stapes head and RWM motion were significant at 0.5 kHz. Conclusion. The LDV results suggested that the higher inner ear impedance in EH affected the dynamic behavior of the two opening windows of the cochlea and then reduced the vibration of the ossicular chain by increasing the afterload, resulting in acoustic dysfunction. The vibration reduction mainly occurred at low frequencies, which has related with the morphology changes of the apical and subapical turns in EH model.

  19. Effect of Endolymphatic Hydrops on Sound Transmission in Live Guinea Pigs Measured with a Laser Doppler Vibrometer

    Directory of Open Access Journals (Sweden)

    Chen-Ru Ding

    2016-01-01

    Full Text Available Objective. This study aimed at describing the mechanism of hearing loss in low frequency and the different dynamic behavior of the umbo, the stapes head, and the round window membrane (RWM between normal guinea pigs and those with endolymphatic hydrops (EH, using a laser Doppler vibrometer (LDV. Methods. Cochlear sections were stained with hematoxylin and eosin (HE to evaluate the hydropic ratio (HR. Auditory brainstem responses (ABR and whole-mount immunostaining were measured. Displacement of the umbo, stapes head, and RWM in response to ear-canal sound was evaluated using a LDV. Results. Mean HR values in EH model of all the turns are larger than the control group. The ABR threshold of the EH group was significantly higher than that of the control. Strong positive correlation was found between HR at apical turn and ABR threshold elevation at 1000 Hz and at subapical turn and ABR threshold elevation at 2000 Hz. FITC-phalloidin immunostaining of the cochlear basilar membrane in the apical, subapical, and suprabasal turns showed missing and derangement stereocilia of third-row outer hair cells. The umbo, stapes head, and RWM displacement in ears with EH was generally lower than that of normal ears. The EH-induced differences in stapes head and RWM motion were significant at 0.5 kHz. Conclusion. The LDV results suggested that the higher inner ear impedance in EH affected the dynamic behavior of the two opening windows of the cochlea and then reduced the vibration of the ossicular chain by increasing the afterload, resulting in acoustic dysfunction. The vibration reduction mainly occurred at low frequencies, which has related with the morphology changes of the apical and subapical turns in EH model.

  20. Cracking the perfusion code?: Laser-assisted Indocyanine Green angiography and combined laser Doppler spectrophotometry for intraoperative evaluation of tissue perfusion in autologous breast reconstruction with DIEP or ms-TRAM flaps.

    Science.gov (United States)

    Ludolph, Ingo; Arkudas, Andreas; Schmitz, Marweh; Boos, Anja M; Taeger, Christian D; Rother, Ulrich; Horch, Raymund E; Beier, Justus P

    2016-10-01

    The aim of this prospective study was to assess the correlation of flap perfusion analysis based on laser-assisted Indocyanine Green (ICG) angiography with combined laser Doppler spectrophotometry in autologous breast reconstruction using free DIEP/ms-TRAM flaps. Between February 2014 and July 2015, 35 free DIEP/ms-TRAM flaps were included in this study. Besides the clinical evaluation of flaps, intraoperative perfusion dynamics were assessed by means of laser-assisted ICG angiography and post-capillary oxygen saturation and relative haemoglobin content (rHb) using combined laser Doppler spectrophotometry. Correlation of the aforementioned parameters was analysed, as well as the impact on flap design and postoperative complications. Flap survival rate was 100%. There were no partial flap losses. In three cases, flap design was based on the angiography, contrary to clinical evaluation and spectrophotometry. The final decision on the inclusion of flap areas was based on the angiographic perfusion pattern. Angiography and spectrophotometry showed a correlation in most of the cases regarding tissue perfusion, post-capillary oxygen saturation and relative haemoglobin content. Laser-assisted ICG angiography is a useful tool for intraoperative evaluation of flap perfusion in autologous breast reconstruction with DIEP/ms-TRAM flaps, especially in decision making in cases where flap perfusion is not clearly assessable by clinical signs and exact determination of well-perfused flap margins is difficult to obtain. It provides an objective real-time analysis of flap perfusion, with high sensitivity for the detection of poorly perfused flap areas. Concerning the topographical mapping of well-perfused flap areas, laser-assisted angiography is superior to combined laser Doppler spectrophotometry.

  1. An Introductory Idea for Teaching Two-Component Phase Diagrams

    Science.gov (United States)

    Peckham, Gavin D.; McNaught, Ian J.

    2011-01-01

    The teaching of two-component phase diagrams has attracted little attention in this "Journal," and it is hoped that this article will make a useful contribution. Current physical chemistry textbooks describe two-component phase diagrams adequately, but do so in a piecemeal fashion one section at a time; first solid-liquid equilibria, then…

  2. Two-component micro injection moulding for hearing aid applications

    DEFF Research Database (Denmark)

    Islam, Aminul; Hansen, Hans Nørgaard; Marhöfer, David Maximilian

    2012-01-01

    Two-component (2k) injection moulding is an important process technique at the present state of technology, and it is growing rapidly in the field of precision micro moulding. Besides combining different material properties in the same product, two-component moulding can eliminate many assembly s...

  3. Feedback Control of Two-Component Regulatory Systems.

    Science.gov (United States)

    Groisman, Eduardo A

    2016-09-08

    Two-component systems are a dominant form of bacterial signal transduction. The prototypical two-component system consists of a sensor that responds to a specific input(s) by modifying the output of a cognate regulator. Because the output of a two-component system is the amount of phosphorylated regulator, feedback mechanisms may alter the amount of regulator, and/or modify the ability of a sensor or other proteins to alter the phosphorylation state of the regulator. Two-component systems may display intrinsic feedback whereby the amount of phosphorylated regulator changes under constant inducing conditions and without the participation of additional proteins. Feedback control allows a two-component system to achieve particular steady-state levels, to reach a given steady state with distinct dynamics, to express coregulated genes in a given order, and to activate a regulator to different extents, depending on the signal acting on the sensor.

  4. Full-field linear and nonlinear measurements using Continuous-Scan Laser Doppler Vibrometry and high speed Three-Dimensional Digital Image Correlation

    Science.gov (United States)

    Ehrhardt, David A.; Allen, Matthew S.; Yang, Shifei; Beberniss, Timothy J.

    2017-03-01

    Spatially detailed dynamic measurements of thin, lightweight structures can be difficult to obtain due to the structure's low mass and complicated deformations under certain loading conditions. If traditional contacting sensors, such as accelerometers, strain gauges, displacement transducers, etc., are used, the total number of measurement locations available is limited by the weight added and the effect each sensor has on the local stiffness of the contact area. Other non-contacting sensors, such as Laser Doppler Vibrometers (LDV), laser triangulation sensors, proximity sensors, etc., do not affect the dynamics of a structure, but are limited to single point measurements. In contrast, a few recently developed non-contacting measurement techniques have been shown to be capable of simultaneously measuring the response over a wide measurement field. Two techniques are considered here: Continuous-Scan Laser Doppler Vibrometry (CSLDV) and high speed Three-Dimensional Digital Image Correlation (3D DIC). With the use of these techniques, unprecedented measurement resolution can be achieved. In this work, the linear and nonlinear deformations of a clamped, nominally flat beam and plate under steady state sinusoidal loading will be measured using both techniques. In order to assess their relative merits, the linear natural frequencies, mode shapes, and nonlinear deformation shapes measured with each method are compared. Both measurement systems give comparable results in many cases, although 3D DIC is more accurate for spatially complex deformations at large amplitudes and CSLDV is more accurate at low amplitudes and when the spatial deformation pattern is simpler.

  5. Documentation and Instructions for Running Two Python Scripts that Aid in Setting up 3D Measurements using the Polytec 3D Scanning Laser Doppler Vibrometer.

    Energy Technology Data Exchange (ETDEWEB)

    Rohe, Daniel Peter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-08-24

    Sandia National Laboratories has recently purchased a Polytec 3D Scanning Laser Doppler Vibrometer for vibration measurement. This device has proven to be a very nice tool for making vibration measurements, and has a number of advantages over traditional sensors such as accelerometers. The non-contact nature of the laser vibrometer means there is no mass loading due to measuring the response. Additionally, the laser scanning heads can position the laser spot much more quickly and accurately than placing an accelerometer or performing a roving hammer impact. The disadvantage of the system is that a significant amount of time must be invested to align the lasers with each other and the part so that the laser spots can be accurately positioned. The Polytec software includes a number of nice tools to aid in this procedure; however, certain portions are still tedious. Luckily, the Polytec software is readily extensible by programming macros for the system, so tedious portions of the procedure can be made easier by automating the process. The Polytec Software includes a WinWrap (similar to Visual Basic) editor and interface to run macros written in that programming language. The author, however, is much more proficient in Python, and the latter also has a much larger set of libraries that can be used to create very complex macros, while taking advantage of Python’s inherent readability and maintainability.

  6. Automated assessment of blood flow in developing embryonic hearts by extending dynamic range of Doppler OCT using a MHz FDML swept laser source (Conference Presentation)

    Science.gov (United States)

    Elahi, Sahar; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2017-02-01

    Altered hemodynamics in developing embryonic hearts lead to congenital heart diseases, motivating close monitoring of blood flow over several stages of development. Doppler OCT can assess blood flow in tubular hearts, but the maximum velocity increases drastically during the period of cardiac cushion (valve precursors) formation. Therefore, the limited dynamic range of Doppler OCT velocity measurement makes it difficult to conduct longitudinal studies without phase wrapping at high velocities or loss of sensitivity to slow velocities. We have built a high-speed OCT system using an FDML laser (Optores GmbH, Germany) at a sweep rate of 1.68 MHz (axial resolution - 12 μm, sensitivity - 105 dB, phase stability - 17 mrad). The speed of this OCT system allows us to acquire high-density B-scans to obtain an extended velocity dynamic range without sacrificing the frame rate. The extended dynamic range within a frame is achieved by varying the A-scan interval at which the phase difference is found, enabling detection of velocities ranging from tens of microns per second to hundreds of mm per second. The extra lines in a frame can also be utilized to improve the structural and Doppler images via complex averaging. In structural images where presence of blood causes additional scattering, complex averaging helps retrieve features located deeper in the tissue. Moreover, high-density frames can be registered to 4D volumes to determine the orthogonal direction of flow and calculate shear stress. In conclusion, our high-speed OCT system will enable automated Doppler imaging of embryonic hearts in cohort studies.

  7. Different imaging methods in the comparative assessment of vascular lesions: color-coded duplex sonography, laser Doppler perfusion imaging, and infrared thermography

    Science.gov (United States)

    Urban, Peter; Philipp, Carsten M.; Weinberg, Lutz; Berlien, Hans-Peter

    1997-12-01

    Aim of the study was the comparative investigation of cutaneous and subcutaneous vascular lesions. By means of color coded duplex sonography (CCDS), laser doppler perfusion imaging (LDPI) and infrared thermography (IT) we examined hemangiomas, vascular malformations and portwine stains to get some evidence about depth, perfusion and vascularity. LDI is a helpful method to get an impression of the capillary part of vascular lesions and the course of superficial vessels. CCDS has disadvantages in the superficial perfusion's detection but connections to deeper vascularizations can be examined precisely, in some cases it is the only method for visualizing vascular malformations. IT gives additive hints on low blood flow areas or indicates arterial-venous-shunts. Only the combination of all imaging methods allows a complete assessment, not only for planning but also for controlling the laser treatment of vascular lesions.

  8. Improving the correlation of structural FEA models by the application of automated high density robotized laser Doppler vibrometry

    Science.gov (United States)

    Chowanietz, Maximilian; Bhangaonkar, Avinash; Semken, Michael; Cockrill, Martin

    2016-06-01

    Sound has had an intricate relation with the wellbeing of humans since time immemorial. It has the ability to enhance the quality of life immensely when present as music; at the same time, it can degrade its quality when manifested as noise. Hence, understanding its sources and the processes by which it is produced gains acute significance. Although various theories exist with respect to evolution of bells, it is indisputable that they carry millennia of cultural significance, and at least a few centuries of perfection with respect to design, casting and tuning. Despite the science behind its design, the nuances pertaining to founding and tuning have largely been empirical, and conveyed from one generation to the next. Post-production assessment for bells remains largely person-centric and traditional. However, progressive bell manufacturers have started adopting methods such as finite element analysis (FEA) for informing and optimising their future model designs. To establish confidence in the FEA process it is necessary to correlate the virtual model against a physical example. This is achieved by performing an experimental modal analysis (EMA) and comparing the results with those from FEA. Typically to collect the data for an EMA, the vibratory response of the structure is measured with the application of accelerometers. This technique has limitations; principally these are the observer effect and limited geometric resolution. In this paper, 3-dimensional laser Doppler vibrometry (LDV) has been used to measure the vibratory response with no observer effect due to the non-contact nature of the technique; resulting in higher accuracy measurements as the input to the correlation process. The laser heads were mounted on an industrial robot that enables large objects to be measured and extensive data sets to be captured quickly through an automated process. This approach gives previously unobtainable geometric resolution resulting in a higher confidence EMA. This is

  9. Vibrational spectra of nanowires measured using laser doppler vibrometry and STM studies of epitaxial graphene : an LDRD fellowship report.

    Energy Technology Data Exchange (ETDEWEB)

    Biedermann, Laura Butler

    2009-09-01

    A few of the many applications for nanowires are high-aspect ratio conductive atomic force microscope (AFM) cantilever tips, force and mass sensors, and high-frequency resonators. Reliable estimates for the elastic modulus of nanowires and the quality factor of their oscillations are of interest to help enable these applications. Furthermore, a real-time, non-destructive technique to measure the vibrational spectra of nanowires will help enable sensor applications based on nanowires and the use of nanowires as AFM cantilevers (rather than as tips for AFM cantilevers). Laser Doppler vibrometry is used to measure the vibration spectra of individual cantilevered nanowires, specifically multiwalled carbon nanotubes (MWNTs) and silver gallium nanoneedles. Since the entire vibration spectrum is measured with high frequency resolution (100 Hz for a 10 MHz frequency scan), the resonant frequencies and quality factors of the nanowires are accurately determined. Using Euler-Bernoulli beam theory, the elastic modulus and spring constant can be calculated from the resonance frequencies of the oscillation spectrum and the dimensions of the nanowires, which are obtained from parallel SEM studies. Because the diameters of the nanowires studied are smaller than the wavelength of the vibrometer's laser, Mie scattering is used to estimate the lower diameter limit for nanowires whose vibration can be measured in this way. The techniques developed in this thesis can be used to measure the vibrational spectra of any suspended nanowire with high frequency resolution Two different nanowires were measured - MWNTs and Ag{sub 2}Ga nanoneedles. Measurements of the thermal vibration spectra of MWNTs under ambient conditions showed that the elastic modulus, E, of plasma-enhanced chemical vapor deposition (PECVD) MWNTs is 37 {+-} 26 GPa, well within the range of E previously reported for CVD-grown MWNTs. Since the Ag{sub 2}Ga nanoneedles have a greater optical scattering efficiency than

  10. Receptor domains of two-component signal transduction systems.

    Science.gov (United States)

    Perry, Julie; Koteva, Kalinka; Wright, Gerard

    2011-05-01

    Two-component signal transduction systems are found ubiquitously in prokaryotes, and in archaea, fungi, yeast and some plants, where they regulate physiologic and molecular processes at both transcriptional and post-transcriptional levels. Two-component systems sense changes in environmental conditions when a specific ligand binds to the receptor domain of the histidine kinase sensory component. The structures of many histidine kinase receptors are known, including those which sense extracellular and cytoplasmic signals. In this review, we discuss the basic architecture of two-component signalling circuits, including known system ligands, structure and function of both receptor and signalling domains, the chemistry of phosphotransfer, and cross-talk between different two-component pathways. Given the importance of these systems in regulating cellular responses, many biochemical techniques have been developed for their study and analysis. We therefore also review current methods used to study two-component signalling, including a new affinity-based proteomics approach used to study inducible resistance to the antibiotic vancomycin through the VanSR two-component signal transduction system.

  11. Caffeine consumption does not have an effect on digital microvascular perfusion assessed by laser Doppler imaging on healthy volunteers: a pilot study.

    Science.gov (United States)

    Knight, R; Pagkalos, J; Timmons, C; Jose, R

    2015-05-01

    Caffeine is one of the most commonly consumed pharmacologically active ingredients in the Western world. It is postulated to cause peripheral vasoconstriction and decreased digital blood flow. As a result, many hand surgeons forbid caffeine consumption post-operatively by patients undergoing replantation surgery for fear of compromising healing. We hypothesized that caffeine has no effect on digital microvascular perfusion. Healthy volunteers were recruited and digital microperfusion was assessed using laser Doppler probes attached to the finger pulp, both before and after ingestion of 100 mg of caffeine. A total of 34 patients were included in the final study. The mean flow before the consumption of caffeine was 226.15 PU. The mean flow following the consumption of caffeine was 197.7 PU. This decrease was not statistically significant. This study revealed no decrease in digital blood flow following the ingestion of 100 mg of caffeine by healthy volunteers, as measured by laser Doppler flow monitoring. 3. © The Author(s) 2014.

  12. Parameter optimization for Doppler laser cooling of a low-energy heavy ion beam at the storage ring S-LSR

    Science.gov (United States)

    Osaki, Kazuya; Okamoto, Hiromi

    2014-05-01

    S-LSR is a compact ion storage ring constructed at Kyoto University several years ago. The ring is equipped with a Doppler laser cooling system aimed at beam crystallization. Bearing in mind hardware limitations in S-LSR, we try to find an optimum set of primary experimental parameters for the production of an ultracold heavy ion beam. Systematic molecular dynamics simulations are carried out for this purpose. It is concluded that the detuning and spot size of the cooling laser should be chosen around -42 MHz and 1.5 mm, respectively, for the most efficient cooling of 40 keV ^{24}Mg^+ beams in S-LSR. Under the optimum conditions, the use of the resonant coupling method followed by radio-frequency field ramping enables us to reach an extremely low beam temperature on the order of 0.1 K in the transverse degrees of freedom. The longitudinal degree of freedom can be cooled to close to the Doppler limit; i.e., to the mK range. We also numerically demonstrate that it is possible to establish a stable, long one-dimensionally ordered state of ions.

  13. A study of vascular response to thermal injury on hairless mice by fibre optic confocal imaging, laser doppler flowmetry and conventional histology.

    Science.gov (United States)

    Vo, L T; Papworth, G D; Delaney, P M; Barkla, D H; King, R G

    1998-06-01

    Burn injury causes vascular thrombosis and occlusion by thermal damage to the vascular network in the dermis. In this study, fibre optic confocal imaging (FOCI) and laser doppler flowmetry were used to detect changes in vascular morphology and local dermal blood flux over 4 h, in three defined zones after a thermal burn (50 degrees C, 20 s duration, 3 mm in diameter) was induced on fully anaesthetised hairless mice. FITC-dextran (i.v.) was used to enable FOCI of vascular morphology including three-dimensional imaging of the burn site and its surrounding areas. Samples of the affected areas were collected for conventional histology, including Masson's trichrome. There was vascular damage in the zone of coagulation which showed no change during the 4 h period. The zone of stasis showed an initial reduction in blood flux and confocal imaging of the area indicated significant vessel leakage during the first 2 h which later improved. The zone of hyperaemia showed an initial increase in total blood flux and confocal imaging of the area showed initial blood vessel dilatation. This study demonstrates that FOCI is a useful non-invasive tool in the assessment of vascular changes in thermal burns in vivo, and compares the findings of FOCI with those from laser doppler flowmetry and histology.

  14. Development and testing of laser Doppler system components for wake vortex monitoring. Volume 1: Scanner development, laboratory and field testing and system modeling

    Science.gov (United States)

    Wilson, D. J.; Krause, M. C.; Coffey, E. W.; Huang, C. C.; Edwards, B. B.; Shrider, K. R.; Jetton, J. L.; Morrison, L. K.

    1974-01-01

    A servo-controlled range/elevation scanner for the laser Doppler velocimeter (LDV) was developed and tested in the field to assess its performance in detecting and monitoring aircraft trailing vortices in an airport environment. The elevation scanner provides a capability to manually point the LDV telescope at operator chosen angles from 3.2 deg. to 89.6 deg within 0.2 deg, or to automatically scan the units between operator chosen limits at operator chosen rates of 0.1 Hz to 0.5 Hz. The range scanner provides a capability to manually adjust the focal point of the system from a range of 32 meters to a range of 896 meters under operator control, or to scan between operator chosen limits and at rates from 0.1 Hz to 6.9 Hz. The scanner controls are designed to allow simulataneous range and elevation scanning so as to provide finger scan patterns, arc scan patterns, and vertical line scan patterns. The development and testing of the unit is discussed, along with a fluid dynamic model of the wake vortex developed in a laser Doppler vortex sensor simulation program.

  15. Preliminary study of a wing-tip vortex using laser velocimetry

    Science.gov (United States)

    Takahashi, R. K.; Mcalister, K. W.

    1987-01-01

    Measurements have been made in the wake of a semi-span NACA 0015 airfoil with emphasis on the region of the wing tip vortex. The spanwise and streamwise velocity components were measured using a two-component laser Doppler velocimeter. The purpose of the study was to initiate the operation of a laser velocimeter system and to perform preliminary wake measurements in preparation for a more extensive study of the structure and near field development of a tip vortex.

  16. Circulation Condition of Two-component Bose-Einstein Condensate

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In the report we point out that there exists an intrinsic difference in the internal symmetry of the two components spin-1/2 Bose condensates from that of spinor Bose condensates of the atoms with hyperfine states of nonzero integer-spins,which gives rise to a new topological constrain on the circulation for this two-component spin-1/2 Bose condensates.It is shown that the SU(2) symmetry of the spin-1/2 Bose condensate implies a

  17. Itinerant Ferromagnetism in a Polarized Two-Component Fermi Gas

    DEFF Research Database (Denmark)

    Massignan, Pietro; Yu, Zhenhua; Bruun, Georg

    2013-01-01

    We analyze when a repulsively interacting two-component Fermi gas becomes thermodynamically unstable against phase separation. We focus on the strongly polarized limit, where the free energy of the homogeneous mixture can be calculated accurately in terms of well-defined quasiparticles, the repul......We analyze when a repulsively interacting two-component Fermi gas becomes thermodynamically unstable against phase separation. We focus on the strongly polarized limit, where the free energy of the homogeneous mixture can be calculated accurately in terms of well-defined quasiparticles...

  18. Izmerenie vektora skorosti lazernym dopplerovskim anemometrom (LDA s volokonno-opticheskimi traktami[Measurement of the velocity vector of the laser Doppler anemometer (LDA with fiber-optic tracts

    Directory of Open Access Journals (Sweden)

    S. N. Khotyaintsev

    1982-12-01

    Full Text Available The problems encountered in the development of laser Doppler velocity vector meter optical fiber paths. The scheme of the meter, including three-dimensional velocity meter made by differential circuit. Describes the experimental setup and the results of the experiment by measuring the two projections of the velocity vector.

  19. Two component permeation through thin zeolite MFI membranes

    NARCIS (Netherlands)

    Keizer, K.; Burggraaf, A.J.; Vroon, Z.A.E.P.; Verweij, H.

    1998-01-01

    Two component permeation measurements have been performed by the Wicke-Kallenbach method on a thin (3 μm) zeolite MFI (Silicalite-1) membrane with molecules of different kinetic diameters, d(k). The membrane was supported by a flat porous α-Al2O3 substrate. The results obtained could be classified i

  20. two component permeation through thin zeolite MFI membranes

    NARCIS (Netherlands)

    Keizer, Klaas; Burggraaf, Anthonie; Burggraaf, A.J.; Vroon, Z.A.E.P.; Vroon, Z.A.E.P.; Verweij, H.

    1998-01-01

    Two component permeation measurements have been performed by the Wicke–Kallenbach method on a thin (3 μm) zeolite MFI (Silicalite-1) membrane with molecules of different kinetic diameters, dk. The membrane was supported by a flat porous -Al2O3 substrate. The results obtained could be classified in s

  1. TWO-COMPONENT JETS AND THE FANAROFF-RILEY DICHOTOMY

    NARCIS (Netherlands)

    Meliani, Z.; Keppens, R.; Sauty, C.

    2010-01-01

    Transversely stratified jets are observed in many classes of astrophysical objects, ranging from young stellar objects, mu-quasars, to active galactic nuclei and even in gamma-ray bursts. Theoretical arguments support this transverse stratification of jets with two components induced by intrinsic fe

  2. Two component injection moulding: Present and future perspectives

    DEFF Research Database (Denmark)

    Islam, Aminul; Hansen, Hans Nørgaard

    2009-01-01

    Two component injection moulding has widespread industrial applications. Still the technology is yet to gain its full potential in highly demanding and technically challenging applications areas. The smart use of this technology can open the doors for cost effective and convergent manufacturing...

  3. Entanglement Properties in Two-Component Bose-Einstein Condensate

    Science.gov (United States)

    Jiang, Di-You

    2016-10-01

    We investigate entanglement inseparability and bipartite entanglement of in two-component Bose-Einstein condensate in the presence of the nonlinear interatomic interaction, interspecies interaction. Entanglement inseparability and bipartite entanglement have the similar properties. More entanglement can be generated by adjusting the nonlinear interatomic interaction and control the time interval of the entanglement by adjusting interspecies interaction.

  4. Goal-Directed Aiming: Two Components but Multiple Processes

    Science.gov (United States)

    Elliott, Digby; Hansen, Steve; Grierson, Lawrence E. M.; Lyons, James; Bennett, Simon J.; Hayes, Spencer J.

    2010-01-01

    This article reviews the behavioral literature on the control of goal-directed aiming and presents a multiple-process model of limb control. The model builds on recent variants of Woodworth's (1899) two-component model of speed-accuracy relations in voluntary movement and incorporates ideas about dynamic online limb control based on prior…

  5. A small protein that mediates the activation of a two-component system by another two-component system

    OpenAIRE

    Kox, Linda F.F.; Wösten, Marc M. S. M.; Groisman, Eduardo A.

    2000-01-01

    The PmrA–PmrB two-component system of Salmonella enterica controls resistance to the peptide antibiotic polymyxin B and to several antimicrobial proteins from human neutrophils. Transcription of PmrA-activated genes is induced by high iron, but can also be promoted by growth in low magnesium in a process that requires another two-component system, PhoP–PhoQ. Here, we define the genetic basis for the interaction between the PhoP–PhoQ and PmrA–PmrB systems. We have identified pmrD as a PhoP-act...

  6. Simultaneous sub-Doppler laser cooling of fermionic $^6$Li and $^{40}$K on the D$_1$ line: Theory and Experiment

    CERN Document Server

    Sievers, Franz; Kretzschmar, Norman; Fernandes, Diogo Rio; Suchet, Daniel; Rabinovic, Michael; Parker, Colin V; Khaykovich, Lev; Salomon, Christophe; Chevy, Frédéric

    2014-01-01

    We report on simultaneous sub-Doppler laser cooling of fermionic $^6$Li and $^{40}$K using the D$_1$ optical transitions. We compare experimental results to a numerical simulation of the cooling process applying a semi-classical Monte Carlo wavefunction method. The simulation takes into account the three dimensional optical molasses setup and the dipole interaction between atoms and the bichromatic light field driving the D$_1$ transitions. We discuss the physical mechanisms at play, we identify the important role of coherences between the ground state hyperfine levels and compare D$_1$ and D$_2$ sub-Doppler cooling. In 5 ms, the D$_1$ molasses phase largely reduces the temperature for both $^6$Li and $^{40}$K at the same time, with a final temperature of 44 $\\mu$K and 11 $\\mu$K, respectively. For both species this leads to a phase-space density close to $10^{-4}$. These conditions are well suited to directly load an optical or magnetic trap for efficient evaporative cooling to quantum degeneracy.

  7. In vivo visualization method by absolute blood flow velocity based on speckle and fringe pattern using two-beam multipoint laser Doppler velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kyoden, Tomoaki, E-mail: kyouden@nc-toyama.ac.jp; Naruki, Shoji; Akiguchi, Shunsuke; Momose, Noboru; Homae, Tomotaka; Hachiga, Tadashi [National Institute of Technology, Toyama College, 1-2 Ebie-Neriya, Imizu, Toyama 933-0293 (Japan); Ishida, Hiroki [Department of Applied Physics, Faculty of Science, Okayama University of Science, 1-1 Ridai-cho, Okayama 700-0005 (Japan); Andoh, Tsugunobu [Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama 930-0194 (Japan); Takada, Yogo [Graduate School of Engineering, Osaka City University, 3-3-138 Sugimoto, Sumiyoshi, Osaka 558-8585 (Japan)

    2016-08-28

    Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensional space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.

  8. Processing of laser Doppler flowmetry signals from healthy subjects and patients with varicose veins: Information categorisation approach based on intrinsic mode functions and entropy computation.

    Science.gov (United States)

    Humeau-Heurtier, Anne; Klonizakis, Markos

    2015-06-01

    The diagnosis of pathologies from signal processing approaches has shown to be of importance. This can provide noninvasive information at the earliest stage. In this work, the problem of categorising - in a quantifiable manner - information content of microvascular blood flow signals recorded in healthy participants and patients with varicose veins is addressed. For this purpose, laser Doppler flowmetry (LDF) signals - that reflect microvascular blood flow - recorded both at rest and after acetylcholine (ACh) stimulation (an endothelial-dependent vasodilator) are analyzed. Each signal is processed with the empirical mode decomposition (EMD) to obtain its intrinsic mode functions (IMFs). An entropy measure of each IMFs is then computed. The results show that IMFs of LDF signals have different complexity for different physiologic/pathological states. This is true both at rest and after ACh stimulation. Thus, the proposed framework (EMD + entropy computation) may be used to gain a noninvasive understanding of LDF signals in patients with microvascular dysfunctions.

  9. Highly spatially resolved velocity measurements of a turbulent channel flow by a fiber-optic heterodyne laser-Doppler velocity-profile sensor

    Energy Technology Data Exchange (ETDEWEB)

    Shirai, K.; Pfister, T.; Buettner, L.; Czarske, J. [Dresden University of Technology (TU Dresden), Department of Electrical Engineering and Information Technology, Chair for Measurement and Testing Techniques, Dresden (Germany); Mueller, H. [Physikalisch-Technische Bundesanstalt Braunschweig (PTB), Department 1.4 Gas Flow, Braunschweig (Germany); Becker, S.; Lienhart, H.; Durst, F. [Institute of Fluid Mechanics (LSTM), Friedrich-Alexander-University Erlangen-Nuernberg, Erlangen (Germany)

    2006-03-15

    Velocity measurements with a high spatial resolution are important in turbulent flow research. In this paper, we report on the development of a new fiber-optic laser-Doppler velocity-profile sensor exhibiting a spatial resolution of up to 5 {mu}m and its application to turbulent boundary layers. The sensor developed in the present work employs a frequency-division-multiplexing technique in order to separate two measurement signals from the two fringe systems. Velocity measurements close to zero at the solid wall were realized using heterodyne technique. The use of fiber optics improved a robustness of the sensor. The measurement accuracy of the sensor was experimentally investigated with respect to the spatial resolution and velocity. Universal velocity profile of a turbulent flow was obtained in a fully developed channel flow. Mean and fluctuating velocity are presented with a high spatial resolution. (orig.)

  10. Laser doppler velocimeter measurements of flow field in structured packing%规整填料内流场的LDV测量

    Institute of Scientific and Technical Information of China (English)

    陈江波; 李莹珂; 黄莹; 刘春江; 袁希钢; 余国琮

    2005-01-01

    @@ Introduction In recent years, structured packing has been widely used in chemical and biochemical industries as internals of static mixers,distillation column and bubble column reactor[1,2].Many researchers have studied its hydrodynamic characteristics with the experimental and computational fluid dynamics (CFD) method.And a great deal of papers about the CFD simulations for structured packing have been reported[3-5].But there is still no published work on experimental measurement of the velocity profiles in the structured packing.Considering the lack of experimental validations of CFD simulation results,laser doppler velocimetry(LDV),was used to measure the velocity profiles in the structured packings in this paper.

  11. Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Swiontkowski, M.F.; Tepic, S.; Perren, S.M.; Moor, R.; Ganz, R.; Rahn, B.A.

    1986-01-01

    Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and /sup 85/Sr-labeled microspheres were made in an adult rabbit model. There was no correlation between the two methods for blood flow in the femoral condyles and the correlation between the two methods for blood flow in the femoral head does not achieve statistical significance. An LDF signal of 0.4 V was approximately equal to a microsphere measured flow rate of 0.4 ml blood/g bone/min. The strength of the correlation in the latter case may have been affected by (a) large arteriovenous shunts, (b) inadequate mixing of the microspheres with a left ventricular injection, and (c) insufficient numbers of microspheres present in the bone samples. When LDF was used to evaluate the effect of elevated intracapsular pressure on femoral head blood flow in skeletally mature rabbits, femoral head subchondral bone blood flow declined with increasing intracapsular pressure from a baseline value of 0.343 +/- 0.036 to a value of 0.127 +/- 0.27 at 120 cm of water pressure. The decline in femoral head blood flow was statistically significant at pressures of 40 cm of water or higher (p less than 0.001), and evaluation of sections of the proximal femora made from preterminal disulphine blue injections confirmed these findings. Intracapsular tamponade has an adverse effect on femoral head blood flow beginning well below central venous pressure and should be considered in the pathophysiology of posttraumatic and nontraumatic necrosis of the femoral head. Laser Doppler flowmetry was easy to use and appears to be a reproducible technique for evaluating femoral head blood flow, offering distinct advantages over the microsphere technique for measuring bone blood flow.

  12. Evaluation of capillary permeability and microcirculation in patients with chronic venous hypertension treated with venoruton by the vacuum suction chamber (VSC) device and laser-Doppler flowmetry.

    Science.gov (United States)

    Belcaro, G; D'Aulerio, A; Rulo, A; Candiani, C

    1988-01-01

    A new system to study capillary permeability, the VSC (vacuum suction chamber) device has been developed to evaluate the variations of capillary permeability in postphlebitic limbs. The VSC device produces by negative pressure [obtained in a plastic chamber applied to the skin at the perimalleolar region] a wheal which disappears in normals in less than one hour. In twelve patients with moderate [superficial] venous hypertension and in twelve patients with postphlebitic limbs the time of disappearance of the wheals was significantly longer in comparison with ten normal limbs. There was also a significantly increased time of disappearance of the wheals in postphlebitic legs in comparison with those with superficial incompetence. The validation of the VSC technique with venous occlusion plethysmography (VOP) showed that the increase of time of disappearance of the wheals is well correlated with the increase of capillary permeability demonstrated by VOP. After 2 weeks treatment with Venoruton (at the dosage of 1000 mg t.i.d.) the time of disappearance of the wheal was significantly reduced in both groups of patients (while it was unchanged in normals). Laser-Doppler parameters used together with the VSC device to evaluate the microcirculatory changes associated with an altered capillary permeability also showed a significant improvement of the laser-Doppler parameters after treatment. In conclusion there is evidence by the VSC device that capillary permeability [which is abnormally increased] in chronic venous hypertension is improved [decreased] after treatment for two weeks with Venoruton. This study demonstrated also the efficacy of the VSC device to study capillary permeability and the effects of drugs active on capillary permeability.

  13. Two-component signal transduction system SaeRS positively regulates Staphylococcus epidermidis glucose metabolism.

    Science.gov (United States)

    Lou, Qiang; Qi, Yijun; Ma, Yuanfang; Qu, Di

    2014-01-01

    Staphylococcus epidermidis, which is a causative pathogen of nosocomial infection, expresses its virulent traits such as biofilm and autolysis regulated by two-component signal transduction system SaeRS. In this study, we performed a proteomic analysis of differences in expression between the S. epidermidis 1457 wild-type and saeRS mutant to identify candidates regulated by saeRS using two-dimensional gel electrophoresis (2-DE) combined with matrix-assisted laser desorption/lonization mass spectrometry (MALDI-TOF-MS). Of 55 identified proteins that significantly differed in expression between the two strains, 15 were upregulated and 40 were downregulated. The downregulated proteins included enzymes related to glycolysis and TCA cycle, suggesting that glucose is not properly utilized in S. epidermidis when saeRS was deleted. The study will be helpful for treatment of S. epidermidis infection from the viewpoint of metabolic modulation dependent on two-component signal transduction system SaeRS.

  14. Spontaneous generation of vortex and coherent vector beams from a thin-slice c-cut Nd:GdVO4 laser with wide-aperture laser-diode end pumping: application to highly sensitive rotational and translational Doppler velocimetry

    Science.gov (United States)

    Otsuka, Kenju; Chu, Shu-Chun

    2017-07-01

    Selective excitation of Laguerre-Gauss modes (optical vortices: helical LG0,2 and LG0,1), reflecting their weak transverse cross-saturation of population inversions against a preceding higher-order Ince-Gauss (IG0,2) or Hermite-Gauss (HG2,1) mode, was observed in a thin-slice c-cut Nd:GdVO4 laser with wide-aperture laser-diode end pumping. Single-frequency coherent vector beams were generated through the transverse mode locking of a pair of orthogonally polarized IG2,0 and LG0,2 or HG2,1 and LG0,1 modes. Highly sensitive self-mixing rotational and translational Doppler velocimetry is demonstrated by using vortex and coherent vector beams.

  15. A two-component NZRI metamaterial based rectangular cloak

    Science.gov (United States)

    Islam, Sikder Sunbeam; Faruque, Mohammd Rashed Iqbal; Islam, Mohammad Tariqul

    2015-10-01

    A new two-component, near zero refractive index (NZRI) metamaterial is presented for electromagnetic rectangular cloaking operation in the microwave range. In the basic design a pi-shaped, metamaterial was developed and its characteristics were investigated for the two major axes (x and z-axis) wave propagation through the material. For the z-axis wave propagation, it shows more than 2 GHz bandwidth and for the x-axis wave propagation; it exhibits more than 1 GHz bandwidth of NZRI property. The metamaterial was then utilized in designing a rectangular cloak where a metal cylinder was cloaked perfectly in the C-band area of microwave regime. The experimental result was provided for the metamaterial and the cloak and these results were compared with the simulated results. This is a novel and promising design for its two-component NZRI characteristics and rectangular cloaking operation in the electromagnetic paradigm.

  16. On a periodic two-component Hunter-Saxton equation

    CERN Document Server

    Kohlmann, Martin

    2011-01-01

    We determine the solution of the geodesic equation associated with a periodic two-component Hunter-Saxton system on a semidirect product obtained from the diffeomorphism group of the circle, modulo rigid rotations, and a space of scalar functions. In particular, we compute the time of breakdown of the geodesic flow. As a further goal, we establish a local well-posedness result for the two-component Hunter-Saxton system in the smooth category. The paper gets in line with some recent results for the generalized Hunter-Saxton equation provided by Escher, Wu and Wunsch in [J. Escher, Preprint 2010] and [H. Wu, M. Wunsch, arXiv:1009.1688v1 [math.AP

  17. Two Component Injection Moulding for Moulded Interconnect Devices

    DEFF Research Database (Denmark)

    Islam, Aminul

    The moulded interconnect devices (MIDs) contain huge possibilities for many applications in micro electro-mechanical-systems because of their potential in reducing the number of components, process steps and finally in miniaturization of the product. Among the available MID process chains, two...... component (2k) injection moulding is one of the most industrially adaptive processes. However, the use of two component injection moulding for MID fabrication, with circuit patterns in sub-millimeter range, is still a big challenge. This book searches for the technical difficulties associated...... with the process and makes attempts to overcome those challenges. In search of suitable polymer materials for MID applications, potential materials are characterized in terms of polymer-polymer bond strength, polymer-polymer interface quality and selective metallization. The experimental results find the factors...

  18. Two-component microinjection moulding for MID fabrication

    DEFF Research Database (Denmark)

    Islam, Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2010-01-01

    Moulded interconnect devices (MIDs) are plastic substrates with electrical infrastructure. The fabrication of MIDs is usually based on injection moulding, and different process chains may be identified from this starting point. The use of MIDs has been driven primarily by the automotive sector......, but recently, the medical sector seems more and more interested. In particular, the possibility of miniaturisation of three-dimensional components with electrical infrastructure is attractive. The present paper describes possible manufacturing routes and challenges of miniaturised MIDs based on two......-component injection moulding and subsequent metallisation. This technology promises cost effective and convergent manufacturing approaches for both macro- and microapplications. This paper presents the results of industrial MID production based on two-component injection moulding and discusses the important issues...

  19. Interaction Analysis of a Two-Component System Using Nanodiscs.

    Directory of Open Access Journals (Sweden)

    Patrick Hörnschemeyer

    Full Text Available Two-component systems are the major means by which bacteria couple adaptation to environmental changes. All utilize a phosphorylation cascade from a histidine kinase to a response regulator, and some also employ an accessory protein. The system-wide signaling fidelity of two-component systems is based on preferential binding between the signaling proteins. However, information on the interaction kinetics between membrane embedded histidine kinase and its partner proteins is lacking. Here, we report the first analysis of the interactions between the full-length membrane-bound histidine kinase CpxA, which was reconstituted in nanodiscs, and its cognate response regulator CpxR and accessory protein CpxP. Using surface plasmon resonance spectroscopy in combination with interaction map analysis, the affinity of membrane-embedded CpxA for CpxR was quantified, and found to increase by tenfold in the presence of ATP, suggesting that a considerable portion of phosphorylated CpxR might be stably associated with CpxA in vivo. Using microscale thermophoresis, the affinity between CpxA in nanodiscs and CpxP was determined to be substantially lower than that between CpxA and CpxR. Taken together, the quantitative interaction data extend our understanding of the signal transduction mechanism used by two-component systems.

  20. Rewiring the specificity of two-component signal transduction systems.

    Science.gov (United States)

    Skerker, Jeffrey M; Perchuk, Barrett S; Siryaporn, Albert; Lubin, Emma A; Ashenberg, Orr; Goulian, Mark; Laub, Michael T

    2008-06-13

    Two-component signal transduction systems are the predominant means by which bacteria sense and respond to environmental stimuli. Bacteria often employ tens or hundreds of these paralogous signaling systems, comprised of histidine kinases (HKs) and their cognate response regulators (RRs). Faithful transmission of information through these signaling pathways and avoidance of detrimental crosstalk demand exquisite specificity of HK-RR interactions. To identify the determinants of two-component signaling specificity, we examined patterns of amino acid coevolution in large, multiple sequence alignments of cognate kinase-regulator pairs. Guided by these results, we demonstrate that a subset of the coevolving residues is sufficient, when mutated, to completely switch the substrate specificity of the kinase EnvZ. Our results shed light on the basis of molecular discrimination in two-component signaling pathways, provide a general approach for the rational rewiring of these pathways, and suggest that analyses of coevolution may facilitate the reprogramming of other signaling systems and protein-protein interactions.

  1. Doppler-free intermodulated fluorescence spectroscopy of $^4He$ $2^3P-3^{1,3}D$ transitions at 588 nm with a one-watt compact laser system

    CERN Document Server

    Luo, Pei-Ling; Feng, Yan; Wang, Li-Bang; Shy, Jow-Tsong

    2015-01-01

    We have demonstrated Doppler-free intermodulated fluorescence spectroscopy of helium $2^3P-3^{1,3}D$ transitions in an rf discharged sealed-off cell using a compact laser system at 588 nm. An external cavity diode laser at 1176 nm was constructed to seed a Raman fiber amplifier. Laser power of more than one watt at 588 nm was produced by frequency doubling of the fiber amplifier output using a MgO:PPLN crystal. A doubling efficiency of 23 % was achieved. The power-dependent spectra of the $2^3P-3^3D$ transitions were investigated. Furthermore, the Doppler-free spectrum of the spin-forbidden $2^3P-3^1D$ transitions was observed for the first time. Our results are crucial towards precision test of QED atomic calculations, especially for improving the determination of the helium $3^1D-3^3D$ separation.

  2. Doppler Tomography

    CERN Document Server

    Marsh, T R

    2000-01-01

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the a...

  3. Azimuthal Doppler Effect in Optical Vortex Spectroscopy

    Science.gov (United States)

    Aramaki, Mitsutoshi; Yoshimura, Shinji; Toda, Yasunori; Morisaki, Tomohiro; Terasaka, Kenichiro; Tanaka, Masayoshi

    2015-11-01

    Optical vortices (OV) are a set of solutions of the paraxial Helmholtz equation in the cylindrical coordinates, and its wave front has a spiral shape. Since the Doppler shift is caused by the phase change by the movement in a wave field, the observer in the OV, which has the three-dimensional structured wave front, feels a three-dimensional Doppler effect. Since the multi-dimensional Doppler components are mixed into a single Doppler spectrum, development of a decomposition method is required. We performed a modified saturated absorption spectroscopy to separate the components. The OV and plane wave are used as a probe beam and pump beam, respectively. Although the plane-wave pump laser cancels the z-direction Doppler shift, the azimuthal Doppler shift remains in the saturated dip. The spatial variation of the dip width gives the information of the azimuthal Doppler shift. The some results of optical vortex spectroscopy will be presented.

  4. Study on All Fiber-optic Laser Doppler Velocimeter%全光纤多普勒测速系统的研究

    Institute of Scientific and Technical Information of China (English)

    谭朝勇; 叶欣; 胡永明

    2011-01-01

    A fiber-optic laser Doppler velocimeter based on Michelson interferometer was described and constructed with fiber laser and fiber collimator. In the experiment of measuring the weak vibration of loudspeaker, good agreement was observed between the fiber-velocimeter and the driving signal. The experiment data dealt with FFT method shows that this system is capable of resolving the velocity less than 1 mm/s,and the resolution is about 0.1 mm/s.%为了验证全光纤多普勒测速系统的低速响应能力,采用窄带光纤激光器、准直透镜等器件搭建了一套迈克尔逊干涉仪结构的全光纤多普勒测速系统,分析了其测速的基本原理,并对喇叭振动进行了测试.采用快速傅里叶变换对信号进行处理,解调结果表明,该系统对低速响应灵敏,能够有效地测量出喇叭膜片振动速度,最低可测速度在1 mm/s以下,速度分辨率可达0.1mm/s.

  5. Skew photonic Doppler velocimetry to investigate the expansion of a cloud of droplets created by micro-spalling of laser shock-melted metal foils

    Energy Technology Data Exchange (ETDEWEB)

    Loison, D.; Resseguier, T. de; Dragon, A. [Institut P' , UPR 3346, CNRS, Universite de Poitiers, ISAE-ENSMA - 1, av Clement Ader, 86961 Futuroscope (France); Mercier, P.; Benier, J.; Deloison, G.; Lescoute, E.; Sollier, A. [CEA, DAM, DIF - 91297 Arpajon (France)

    2012-12-01

    Dynamic fragmentation in the liquid state after shock-induced melting, usually referred to as micro-spallation, is an issue of great interest for both basic and applied sciences. Recent efforts have been devoted to the characterization of the resulting ejecta, which consist in a cloud of fine molten droplets. Major difficulties arise from the loss of free surface reflectivity at shock breakout and from the wide distribution of particle velocities within this cloud. We present laser shock experiments on tin and aluminium, to pressures ranging from about 70 to 160 GPa, with complementary diagnostics including a photonic Doppler velocimeter set at a small tilt angle from the normal to the free surface, which enables probing the whole cloud of ejecta. The records are roughly consistent with a one-dimensional theoretical description accounting for laser shock loading, wave propagation, phase transformations, and fragmentation. The main discrepancies between measured and calculated velocity profiles are discussed in terms of edge effects evidenced by transverse shadowgraphy.

  6. Two-Component Multi-Parameter Time-Frequency Electromagnetics

    Institute of Scientific and Technical Information of China (English)

    HuangZhou; DongWeibin; HeTiezhi

    2003-01-01

    The two-component multi-parameter time-frequency electromagnetic method, used for the development of oilfields,makes use of both the traditional individual conductivity parameters of oil-producing layers and the dispersion information of the conductivity, i.e., the induced polarization parameter. The frequency-domain dispersion data is used to delineate the contacts between oil and water and the time domain dBz/dt component is used to estimate the depths to the un-known reservoirs so as to offer significant data in many aspects for oil exploration and detection.

  7. Two component micro injection moulding for moulded interconnect devices

    DEFF Research Database (Denmark)

    Islam, Aminul

    2008-01-01

    Moulded interconnect devices (MIDs) contain huge possibilities for many applications in micro electro-mechanical-systems because of their capability of reducing the number of components, process steps and finally in miniaturization of the product. Among the available MID process chains, two...... and a reasonable adhesion between them. • Selective metallization of the two component plastic part (coating one polymer with metal and leaving the other one uncoated) To overcome these two main issues in MID fabrication for micro applications, the current Ph.D. project explores the technical difficulties...

  8. Two-component Fermi gas in a Harmonic Trap

    CERN Document Server

    Yi, X X; Cui, H T; Zhang, C M

    2002-01-01

    We consider a mixture of two-component Fermi gases at low temperature. The density profile of this degenerate Fermi gas is calculated under the semiclassical approximation. The results show that the fermion-fermion interactions make a large correction to the density profile at low temperature. The phase separation of such a mixture is also discussed for both attractive and repulsive interatomic interactions, and the numerical calculations demonstrate the exist of a stable temperature region $T_{c1}

  9. Interaction potentials and thermodynamic properties of two component semiclassical plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ramazanov, T. S.; Moldabekov, Zh. A.; Ismagambetova, T. N. [Al-Farabi Kazakh National University, IETP, 71 al-Farabi Av., Almaty 050040 (Kazakhstan); Gabdullin, M. T. [Al-Farabi Kazakh National University, NNLOT, 71 al-Farabi Av., Almaty 050040 (Kazakhstan)

    2014-01-15

    In this paper, the effective interaction potential in two component semiclassical plasma, taking into account the long-range screening and the quantum-mechanical diffraction effects at short distances, is obtained on the basis of dielectric response function method. The structural properties of the semiclassical plasma are considered. The thermodynamic characteristics (the internal energy and the equation of state) are calculated using two methods: the method of effective potentials and the method of micropotentials with screening effect taken into account by the Ornstein-Zernike equation in the HNC approximation.

  10. Itinerant ferromagnetism in a polarized two-component Fermi gas.

    Science.gov (United States)

    Massignan, Pietro; Yu, Zhenhua; Bruun, Georg M

    2013-06-07

    We analyze when a repulsively interacting two-component Fermi gas becomes thermodynamically unstable against phase separation. We focus on the strongly polarized limit, where the free energy of the homogeneous mixture can be calculated accurately in terms of well-defined quasiparticles, the repulsive polarons. Phase diagrams as a function of polarization, temperature, mass imbalance, and repulsive polaron energy, as well as scattering length and range parameter, are provided. We show that the lifetime of the repulsive polaron increases significantly with the interaction range and the mass of the minority atoms, raising the prospects of detecting the transition to the elusive itinerant ferromagnetic state with ultracold atoms.

  11. Two component micro injection molding for MID fabrication

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2009-01-01

    Molded Interconnect Devices (MIDs) are plastic substrates with electrical infrastructure. The fabrication of MIDs is usually based on injection molding and different process chains may be identified from this starting point. The use of MIDs has been driven primarily by the automotive sector......, but recently the medical sector seems more and more interested. In particular the possibility of miniaturization of 3D components with electrical infrastructure is attractive. The paper describes possible manufacturing routes and challenges of miniaturized MIDs based on two component micro injection molding...

  12. Doppler imaging

    Energy Technology Data Exchange (ETDEWEB)

    Piskunov, N [Department of Physics and Astronomy, Uppsala University, Box 515, S-75120 Uppsala (Sweden)], E-mail: piskunov@fysast.uu.se

    2008-12-15

    In this paper, I present a short review of the history and modern status of Doppler imaging techniques, highlighting their dependence on the knowledge of the fundamental stellar parameters, the quality of stellar atmospheric models and the accuracy of spectral synthesis.

  13. Extended dynamic range of Doppler OCT by application of a new method to high density B-scans using a MHz FDML swept laser source (Conference Presentation)

    Science.gov (United States)

    Elahi, Sahar; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2017-02-01

    The limited dynamic range of optical coherence tomography (OCT) Doppler velocity measurements makes it difficult to conduct experiments on samples requiring a large dynamic range without phase wrapping at high velocities or loss of sensitivity at slow velocities. Hemodynamics and wall motion undergo significant increases in velocity as the embryonic heart develops. Experimental studies indicate that altered hemodynamics in early-stage embryonic hearts can lead to congenital heart diseases (CHDs), motivating close monitoring of blood flow over several stages of development. We have built a high-speed OCT system using an FDML laser (Optores GmbH, Germany) at a sweep rate of 1.68 MHz (axial resolution - 12 μm, sensitivity - 105 dB, phase stability - 17 mrad). The speed of this OCT system allows us to acquire high-density B-scans to obtain an extended velocity dynamic range without sacrificing the frame rate (100 Hz). The extended dynamic range within a frame is achieved by varying the A-scan interval at which the phase difference is found, enabling detection of velocities ranging from tens of microns per second to hundreds of millimeters per second. The extra lines in a frame can also be utilized to improve the structural and Doppler images via complex averaging. In structural images where the presence of blood causes additional scattering, complex averaging helps retrieve features located deeper in the tissue. Moreover, high-density frames can be registered to 4D volumes to determine the orthogonal direction of flow for calculating shear stress as well as estimating the cardiac output. In conclusion, high density B-scans acquired by our high-speed OCT system enable image enhancement and direct measurement of biological parameters in cohort studies.

  14. Graphene Oxide: A One- versus Two-Component Material.

    Science.gov (United States)

    Naumov, Anton; Grote, Fabian; Overgaard, Marc; Roth, Alexandra; Halbig, Christian E; Nørgaard, Kasper; Guldi, Dirk M; Eigler, Siegfried

    2016-09-14

    The structure of graphene oxide (GO) is a matter of discussion. While established GO models are based on functional groups attached to the carbon framework, another frequently used model claims that GO consists of two components, a slightly oxidized graphene core and highly oxidized molecular species, oxidative debris (OD), adsorbed on it. Those adsorbents are claimed to be the origin for optical properties of GO. Here, we examine this model by preparing GO with a low degree of functionalization, combining it with OD and studying the optical properties of both components and their combination in an artificial two-component system. The analyses of absorption and emission spectra as well as lifetime measurements reveal that properties of the combined system are distinctly different from those of GO. That confirms structural models of GO as a separate oxygenated hexagonal carbon framework with optical properties governed by its internal structure rather than the presence of OD. Understanding the structure of GO allows further reliable interpretation of its optical and electronic properties and enables controlled processing of GO.

  15. Evolution of two-component signal transduction systems.

    Science.gov (United States)

    Capra, Emily J; Laub, Michael T

    2012-01-01

    To exist in a wide range of environmental niches, bacteria must sense and respond to a variety of external signals. A primary means by which this occurs is through two-component signal transduction pathways, typically composed of a sensor histidine kinase that receives the input stimuli and then phosphorylates a response regulator that effects an appropriate change in cellular physiology. Histidine kinases and response regulators have an intrinsic modularity that separates signal input, phosphotransfer, and output response; this modularity has allowed bacteria to dramatically expand and diversify their signaling capabilities. Recent work has begun to reveal the molecular basis by which two-component proteins evolve. How and why do orthologous signaling proteins diverge? How do cells gain new pathways and recognize new signals? What changes are needed to insulate a new pathway from existing pathways? What constraints are there on gene duplication and lateral gene transfer? Here, we review progress made in answering these questions, highlighting how the integration of genome sequence data with experimental studies is providing major new insights.

  16. The Evolution of Two-Component Signal Transduction Systems

    Science.gov (United States)

    Capra, Emily J.; Laub, Michael T.

    2014-01-01

    To exist in a wide range of environmental niches, bacteria must sense and respond to a myriad of external signals. A primary means by which this occurs is through two-component signal transduction pathways, typically comprised of a histidine kinase that receives the input stimuli and a response regulator that effects an appropriate change in cellular physiology. Histidine kinases and response regulators have an intrinsic modularity that separates signal input, phosphotransfer, and output response; this modularity has allowed bacteria to dramatically expand and diversify their signaling capabilities. Recent work has begun to reveal the molecular basis by which two-component proteins evolve. How and why do orthologous signaling proteins diverge? How do cells gain new pathways and recognize new signals? What changes are needed to insulate a new pathway from existing pathways? What constraints are there on gene duplication and lateral gene transfer? Here, we review progress made in answering these questions, highlighting how the integration of genome sequence data with experimental studies is providing major new insights. PMID:22746333

  17. Field test of an all-semiconductor laser-based coherent continuous-wave Doppler lidar for wind energy applications

    DEFF Research Database (Denmark)

    Sjöholm, Mikael; Dellwik, Ebba; Hu, Qi

    The wind energy industry is gaining interest in prevision of the rotor inflow for turbine control. The potential benefits are increased power production due to better alignment of the rotor to the mean wind direction as well as prolonged lifetime of the turbine due to load reductions. Several lidar......-produced all-semiconductor laser. The instrument is a coherent continuous-wave lidar with two fixed-focus telescopes for launching laser beams in two different directions. The alternation between the telescopes is achieved by a novel switching technique without any moving parts. Here, we report results from...

  18. Self-mixing laser Doppler vibrometry with high optical sensitivity application to real-time sound reproduction

    CERN Document Server

    Abe, K; Ko, J Y

    2003-01-01

    Nanometre vibration measurement of an audio speaker and a highly sensitive sound reproduction experiment have been successfully demonstrated by a self-aligned optical feedback vibrometry technique using the self-mixing modulation effect in a laser-diode-pumped microchip solid-state laser. By applying nanometre vibrations to the speaker, which produced nearly inaudible music below 20 dB (200 mu Pa) sound pressure level, we could reproduce clear sound in real time by the use of a simple frequency modulated wave demodulation circuit with a -120 dB light-intensity feedback ratio.

  19. Two-component systems and toxinogenesis regulation in Clostridium botulinum.

    Science.gov (United States)

    Connan, Chloé; Popoff, Michel R

    2015-05-01

    Botulinum neurotoxins (BoNTs) are the most potent toxins ever known. They are mostly produced by Clostridium botulinum but also by other clostridia. BoNTs associate with non-toxic proteins (ANTPs) to form complexes of various sizes. Toxin production is highly regulated through complex networks of regulatory systems involving an alternative sigma factor, BotR, and at least 6 recently described two-component systems (TCSs). TCSs allow bacteria to sense environmental changes and to respond to various stimuli by regulating the expression of specific genes at a transcriptional level. Several environmental stimuli have been identified to positively or negatively regulate toxin synthesis; however, the link between environmental stimuli and TCSs is still elusive. This review aims to highlight the role of TCSs as a central point in the regulation of toxin production in C. botulinum.

  20. Exact two-component relativistic energy band theory and application

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Rundong; Zhang, Yong; Xiao, Yunlong; Liu, Wenjian, E-mail: liuwj@pku.edu.cn [Beijing National Laboratory for Molecular Sciences, Institute of Theoretical and Computational Chemistry, State Key Laboratory of Rare Earth Materials Chemistry and Applications, College of Chemistry and Molecular Engineering, and Center for Computational Science and Engineering, Peking University, Beijing 100871 (China)

    2016-01-28

    An exact two-component (X2C) relativistic density functional theory in terms of atom-centered basis functions is proposed for relativistic calculations of band structures and structural properties of periodic systems containing heavy elements. Due to finite radial extensions of the local basis functions, the periodic calculation is very much the same as a molecular calculation, except only for an Ewald summation for the Coulomb potential of fluctuating periodic monopoles. For comparison, the nonrelativistic and spin-free X2C counterparts are also implemented in parallel. As a first and pilot application, the band gaps, lattice constants, cohesive energies, and bulk moduli of AgX (X = Cl, Br, I) are calculated to compare with other theoretical results.

  1. Dynamics of two-component membranes surrounded by viscoelastic media.

    Science.gov (United States)

    Komura, Shigeyuki; Yasuda, Kento; Okamoto, Ryuichi

    2015-11-01

    We discuss the dynamics of two-component fluid membranes which are surrounded by viscoelastic media. We assume that membrane-embedded proteins can diffuse laterally and induce a local membrane curvature. The mean squared displacement of a tagged membrane segment is obtained as a generalized Einstein relation. When the elasticity of the surrounding media obeys a power-law behavior in frequency, an anomalous diffusion of the membrane segment is predicted. We also consider the situation where the proteins generate active non-equilibrium forces. The generalized Einstein relation is further modified by an effective temperature that depends on the force dipole energy. The obtained generalized Einstein relations are useful for membrane microrheology experiments.

  2. Two-component jet simulations: Combining analytical and numerical approaches

    CERN Document Server

    Matsakos, T; Trussoni, E; Tsinganos, K; Vlahakis, N; Sauty, C; Mignone, A

    2009-01-01

    Recent observations as well as theoretical studies of YSO jets suggest the presence of two steady components: a disk wind type outflow needed to explain the observed high mass loss rates and a stellar wind type outflow probably accounting for the observed stellar spin down. In this framework, we construct numerical two-component jet models by properly mixing an analytical disk wind solution with a complementary analytically derived stellar outflow. Their combination is controlled by both spatial and temporal parameters, in order to address different physical conditions and time variable features. We study the temporal evolution and the interaction of the two jet components on both small and large scales. The simulations reach steady state configurations close to the initial solutions. Although time variability is not found to considerably affect the dynamics, flow fluctuations generate condensations, whose large scale structures have a strong resemblance to observed YSO jet knots.

  3. Exact two-component relativistic energy band theory and application.

    Science.gov (United States)

    Zhao, Rundong; Zhang, Yong; Xiao, Yunlong; Liu, Wenjian

    2016-01-28

    An exact two-component (X2C) relativistic density functional theory in terms of atom-centered basis functions is proposed for relativistic calculations of band structures and structural properties of periodic systems containing heavy elements. Due to finite radial extensions of the local basis functions, the periodic calculation is very much the same as a molecular calculation, except only for an Ewald summation for the Coulomb potential of fluctuating periodic monopoles. For comparison, the nonrelativistic and spin-free X2C counterparts are also implemented in parallel. As a first and pilot application, the band gaps, lattice constants, cohesive energies, and bulk moduli of AgX (X = Cl, Br, I) are calculated to compare with other theoretical results.

  4. Recent advances in description of few two-component fermions

    CERN Document Server

    Kartavtsev, O I

    2012-01-01

    Overview of the recent advances in description of the few two-component fermions is presented. The zero-range interaction limit is generally considered to discuss the principal aspects of the few-body dynamics. Significant attention is paid to detailed description of two identical fermions of mass $m$ and a distinct particle of mass $m_1$; two universal $L^P = 1^-$ bound states arise for mass ratio $m/m_1$ increasing up to the critical value $\\mu_c \\approx 13.607$, beyond which the Efimov effect takes place. The topics considered include rigorous treatment of the few-fermion problem in the zero-range interaction limit, low-dimensional results, the four-body energy spectrum, crossover of the energy spectra for $m/m_1$ near the critical value $\\mu_c $, and properties of potential-dependent states. At last, enlisted are the problems, whose solution is in due course.

  5. Molecular Mechanisms of Two-Component Signal Transduction.

    Science.gov (United States)

    Zschiedrich, Christopher P; Keidel, Victoria; Szurmant, Hendrik

    2016-09-25

    Two-component systems (TCS) comprising sensor histidine kinases and response regulator proteins are among the most important players in bacterial and archaeal signal transduction and also occur in reduced numbers in some eukaryotic organisms. Given their importance to cellular survival, virulence, and cellular development, these systems are among the most scrutinized bacterial proteins. In the recent years, a flurry of bioinformatics, genetic, biochemical, and structural studies have provided detailed insights into many molecular mechanisms that underlie the detection of signals and the generation of the appropriate response by TCS. Importantly, it has become clear that there is significant diversity in the mechanisms employed by individual systems. This review discusses the current knowledge on common themes and divergences from the paradigm of TCS signaling. An emphasis is on the information gained by a flurry of recent structural and bioinformatics studies.

  6. Bond strength of two component injection moulded MID

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2006-01-01

    Most products of the future will require industrially adapted, cost effective production processes and on this issue two-component (2K) injection moulding is a potential candidate for MID manufacturing. MID based on 2k injection moulded plastic part with selectively metallised circuit tracks allows...... the integration of electrical and mechanical functionalities in a real 3D structure. If 2k injection moulding is applied with two polymers, of which one is plateable and the other is not, it will be possible to make 3D electrical structures directly on the component. To be applicable in the real engineering field...... the two different plastic materials in the MID structure require good bonding between them. This paper finds suitable combinations of materials for MIDs from both bond strength and metallisation view-point. Plastic parts were made by two-shot injection moulding and the effects of some important process...

  7. Efficient two-component relativistic method for large systems

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, Hiromi [Department of Chemitsry and Biochemistry, School of Advanced Science and Engineering, Waseda University, Tokyo 169-8555 (Japan); Research Institute for Science and Engineering, Waseda University, Tokyo 169-8555 (Japan); CREST, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012 (Japan); Elements Strategy Initiative for Catalysts and Batteries (ESICB), Kyoto University, Katsura, Kyoto 615-8520 (Japan)

    2015-12-31

    This paper reviews a series of theoretical studies to develop efficient two-component (2c) relativistic method for large systems by the author’s group. The basic theory is the infinite-order Douglas-Kroll-Hess (IODKH) method for many-electron Dirac-Coulomb Hamiltonian. The local unitary transformation (LUT) scheme can effectively produce the 2c relativistic Hamiltonian, and the divide-and-conquer (DC) method can achieve linear-scaling of Hartree-Fock and electron correlation methods. The frozen core potential (FCP) theoretically connects model potential calculations with the all-electron ones. The accompanying coordinate expansion with a transfer recurrence relation (ACE-TRR) scheme accelerates the computations of electron repulsion integrals with high angular momenta and long contractions.

  8. No electrostatic supersolitons in two-component plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Verheest, Frank, E-mail: frank.verheest@ugent.be [Sterrenkundig Observatorium, Universiteit Gent, Krijgslaan 281, B–9000 Gent (Belgium); School of Chemistry and Physics, University of KwaZulu-Natal, Durban 4000 (South Africa); Lakhina, Gurbax S., E-mail: lakhina@iigm.iigs.res.in [Indian Institute of Geomagnetism, New Panvel (W), Navi Mumbai (India); Hellberg, Manfred A., E-mail: hellberg@ukzn.ac.za [School of Chemistry and Physics, University of KwaZulu-Natal, Durban 4000 (South Africa)

    2014-06-15

    The concept of acoustic supersolitons was introduced for a very specific plasma with five constituents, and discussed only for a single set of plasma parameters. Supersolitons are characterized by having subsidiary extrema on the sides of a typical bipolar electric field signature, or by association with a root beyond double layers in the fully nonlinear Sagdeev pseudopotential description. It was subsequently found that supersolitons could exist in several plasma models having three constituent species, rather than four or five. In the present paper, it is proved that standard two-component plasma models cannot generate supersolitons, by recalling and extending results already in the literature, and by establishing the necessary properties of a more recent model.

  9. Budding Transition of Asymmetric Two-component Lipid Domains

    CERN Document Server

    Wolff, Jean; Andelman, David

    2016-01-01

    We propose a model that accounts for the budding transition of asymmetric two-component lipid domains, where the two monolayers (leaflets) have different average compositions controlled by independent chemical potentials. Assuming a coupling between the local curvature and local lipid composition in each of the leaflets, we discuss the morphology and thermodynamic behavior of asymmetric lipid domains. The membrane free-energy contains three contributions: the bending energy, the line tension, and a Landau free-energy for a lateral phase separation. Within a mean-field treatment, we obtain various phase diagrams containing fully budded, dimpled, and flat states as a function of the two leaflet compositions. The global phase behavior is analyzed, and depending on system parameters, the phase diagrams include one-phase, two-phase and three-phase regions. In particular, we predict various phase coexistence regions between different morphologies of domains, which may be observed in multi-component membranes or ves...

  10. The mechanism of signal transduction by two-component systems.

    Science.gov (United States)

    Casino, Patricia; Rubio, Vicente; Marina, Alberto

    2010-12-01

    Two-component systems, composed of a homodimeric histidine kinase (HK) and a response regulator (RR), are major signal transduction devices in bacteria. Typically the signal triggers HK autophosphorylation at one His residue, followed by phosphoryl transfer from the phospho-His to an Asp residue in the RR. Signal extinction frequently involves phospho-RR dephosphorylation by a phosphatase activity of the HK. Our understanding of these reactions and of the determinants of partner specificity among HK-RR couples has been greatly increased by recent crystal structures and biochemical experiments on HK-RR complexes. Cis-autophosphorylation (one subunit phosphorylates itself) occurs in some HKs while trans-autophosphorylation takes place in others. We review and integrate this new information, discuss the mechanism of the three reactions and propose a model for transmembrane signaling by these systems. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Determinants of specificity in two-component signal transduction.

    Science.gov (United States)

    Podgornaia, Anna I; Laub, Michael T

    2013-04-01

    Maintaining the faithful flow of information through signal transduction pathways is critical to the survival and proliferation of organisms. This problem is particularly challenging as many signaling proteins are part of large, paralogous families that are highly similar at the sequence and structural levels, increasing the risk of unwanted cross-talk. To detect environmental signals and process information, bacteria rely heavily on two-component signaling systems comprised of sensor histidine kinases and their cognate response regulators. Although most species encode dozens of these signaling pathways, there is relatively little cross-talk, indicating that individual pathways are well insulated and highly specific. Here, we review the molecular mechanisms that enforce this specificity. Further, we highlight recent studies that have revealed how these mechanisms evolve to accommodate the introduction of new pathways by gene duplication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Rewiring two-component signal transduction with small RNAs.

    Science.gov (United States)

    Göpel, Yvonne; Görke, Boris

    2012-04-01

    Bacterial two-component systems (TCSs) and small regulatory RNAs (sRNAs) form densely interconnected networks that integrate and transduce information from the environment into fine-tuned changes of gene expression. Many TCSs control target genes indirectly through regulation of sRNAs, which in turn regulate gene expression by base-pairing with mRNAs or targeting a protein. Conversely, sRNAs may control TCS synthesis, thereby recruiting the TCS regulon to other regulatory networks. Several TCSs control expression of multiple homologous sRNAs providing the regulatory networks with further flexibility. These sRNAs act redundantly, additively or hierarchically on targets. The regulatory speed of sRNAs and their unique features in gene regulation make them ideal players extending the flexibility, dynamic range or timing of TCS signaling. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Auxiliary phosphatases in two-component signal transduction.

    Science.gov (United States)

    Silversmith, Ruth E

    2010-04-01

    Signal termination in two-component systems occurs by loss of the phosphoryl group from the response regulator protein. This review explores our current understanding of the structures, catalytic mechanisms and means of regulation of the known families of phosphatases that catalyze response regulator dephosphorylation. The CheZ and CheC/CheX/FliY families, despite different overall structures, employ identical catalytic strategies using an amide side chain to orient a water molecule for in-line attack of the aspartyl phosphate. Spo0E phosphatases contain sequence and structural features that suggest a strategy similar to the chemotaxis phosphatases but the mechanism used by the Rap phosphatases is not yet elucidated. Identification of features shared by phosphatase families may aid in the identification of currently unrecognized classes of response regulator phosphatases. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. How insects overcome two-component plant chemical defence

    DEFF Research Database (Denmark)

    Pentzold, Stefan; Zagrobelny, Mika; Rook, Frederik;

    2014-01-01

    Insect herbivory is often restricted by glucosylated plant chemical defence compounds that are activated by plant β-glucosidases to release toxic aglucones upon plant tissue damage. Such two-component plant defences are widespread in the plant kingdom and examples of these classes of compounds...... are alkaloid, benzoxazinoid, cyanogenic and iridoid glucosides as well as glucosinolates and salicinoids. Conversely, many insects have evolved a diversity of counteradaptations to overcome this type of constitutive chemical defence. Here we discuss that such counter-adaptations occur at different time points......-component chemical defence. These adaptations include host plant choice, non-disruptive feeding guilds and various physiological adaptations as well as metabolic enzymatic strategies of the insect’s digestive system. Furthermore, insect adaptations often act in combination, may exist in both generalists...

  15. Parallel TREE code for two-component ultracold plasma analysis

    Science.gov (United States)

    Jeon, Byoungseon; Kress, Joel D.; Collins, Lee A.; Grønbech-Jensen, Niels

    2008-02-01

    The TREE method has been widely used for long-range interaction N-body problems. We have developed a parallel TREE code for two-component classical plasmas with open boundary conditions and highly non-uniform charge distributions. The program efficiently handles millions of particles evolved over long relaxation times requiring millions of time steps. Appropriate domain decomposition and dynamic data management were employed, and large-scale parallel processing was achieved using an intermediate level of granularity of domain decomposition and ghost TREE communication. Even though the computational load is not fully distributed in fine grains, high parallel efficiency was achieved for ultracold plasma systems of charged particles. As an application, we performed simulations of an ultracold neutral plasma with a half million particles and a half million time steps. For the long temporal trajectories of relaxation between heavy ions and light electrons, large configurations of ultracold plasmas can now be investigated, which was not possible in past studies.

  16. Quantum melting of two-component Rydberg crystals

    CERN Document Server

    Lan, Zhihao; Lesanovsky, Igor

    2016-01-01

    We investigate the quantum melting of one dimensional crystals that are realized in an atomic lattice in which ground state atoms are laser excited to two Rydberg states. We focus on a regime where both, intra- and inter-state density-density interactions as well as coherent exchange interactions contribute. We determine stable crystalline phases in the classical limit and explore their melting under quantum fluctuations introduced by the excitation laser as well as two-body exchange. We find that quantum fluctuations introduced by the laser give rise to a devil's staircase structure which one might associate with transitions in the classical limit. The melting through exchange interactions is shown to also proceed in a step-like fashion, in case of mesoscopic crystals, due to the proliferation of Rydberg spinwaves.

  17. Effects of alpha-trinositol on peripheral circulation in diabetic patients with critical limb ischaemia. A pilot study using laser Doppler fluxmetry, transcutaneous oxygen tension measurements and dynamic capillaroscopy

    DEFF Research Database (Denmark)

    Nilsson, L; Apelqvist, J; Edvinsson, L

    1998-01-01

    the start of the administration. There were no detectable changes in blood pressure or heart rate. Laser Doppler flux increased from 41% to 57.5% and tcPO2 changed from 116 to 91 s in "half time recovery" after occlusion. Capillary blood flow showed an increase in resting velocity from 0.1 to 0.5 mm/s at 24...

  18. Visualization of Lamb Wave Interaction with a 5 mm Fatigue Crack using 1D Ultra High Frequency Laser Doppler Vibrometry

    Science.gov (United States)

    2011-09-01

    presence affected the measurement results presented later in the paper. A Polytec UHF-120 scanning laser vibrometer system (Figure 2) was used to... Polytec Scanning Vibrometer (PSV) software from the PC. The oscilloscope is required due to the extremely high sample rate required for UHF...Figure 2: Polytec UHF-120 Scanning LDV System Sampled heterodyne data are sent to the PC via Ethernet cable where the PSV software performs the

  19. Dynamic characteristics of laser Doppler flowmetry signals obtained in response to a local and progressive pressure applied on diabetic and healthy subjects

    Science.gov (United States)

    Humeau, Anne; Koitka, Audrey; Abraham, Pierre; Saumet, Jean-Louis; L'Huillier, Jean-Pierre

    2004-09-01

    In the biomedical field, the laser Doppler flowmetry (LDF) technique is a non-invasive method to monitor skin perfusion. On the skin of healthy humans, LDF signals present a significant transient increase in response to a local and progressive pressure application. This vasodilatory reflex response may have important implications for cutaneous pathologies involved in various neurological diseases and in the pathophysiology of decubitus ulcers. The present work analyses the dynamic characteristics of these signals on young type 1 diabetic patients, and on healthy age-matched subjects. To obtain accurate dynamic characteristic values, a de-noising wavelet-based algorithm is first applied to LDF signals. All the de-noised signals are then normalised to the same value. The blood flow peak and the time to reach this peak are then calculated on each computed signal. The results show that a large vasodilation is present on signals of healthy subjects. The mean peak occurs at a pressure of 3.2 kPa approximately. However, a vasodilation of limited amplitude appears on type 1 diabetic patients. The maximum value is visualised, on the average, when the pressure is 1.1 kPa. The inability for diabetic patients to increase largely their cutaneous blood flow may bring explanations to foot ulcers.

  20. Dynamic characteristics of the cutaneous vasodilator response to a local external pressure application detected by the laser Doppler flowmetry technique on anesthetized rats

    Science.gov (United States)

    Humeau, Anne; Koitka, Audrey; Saumet, Jean-Louis; L'Huillier, Jean-Pierre

    2003-10-01

    The laser Doppler flowmetry technique has recently been used to report a significant transient increase of the cutaneous blood flow signal when a local non-noxious pressure is applied progressively on the skin (11.1 Pa/s). The present work analyses the dynamic characteristics of this vasodilatory reflex response on anaesthetised rats. A de-noising algorithm using wavelets is proposed to obtain accurate values of these dynamic characteristics. The blood flow peak and the time to reach this peak are computed on the de-noised recordings. The results show that the mean time to reach the peak of perfusion is 85.3 s (time t = 0 at the beginning of the pressure application). The mean peak value is 188.3 arbitrary units (a.u.), whereas the mean value of the perfusion before the pressure application is 113.4 a.u. The mean minimum value obtained at the end of the experiment is 60.7 a.u. This latter value is, on the average, reached 841.3 s after the beginning of the pressure application. The comparison of the dynamic characteristics, computed with the de-noising algorithm on signals obtained in other situations, will give a better understanding on some cutaneous lesions such as those present on diabetic people.

  1. Insights into the use of thermography to assess burn wound healing potential: a reliable and valid technique when compared to laser Doppler imaging

    Science.gov (United States)

    Jaspers, Mariëlle E. H.; Maltha, Ilse; Klaessens, John H. G. M.; de Vet, Henrica C. W.; Verdaasdonk, Rudolf M.; van Zuijlen, Paul P. M.

    2016-09-01

    Adequate assessment of burn wounds is crucial in the management of burn patients. Thermography, as a noninvasive measurement tool, can be utilized to detect the remaining perfusion over large burn wound areas by measuring temperature, thereby reflecting the healing potential (HP) (i.e., number of days that burns require to heal). The objective of this study was to evaluate the clinimetric properties (i.e., reliability and validity) of thermography for measuring burn wound HP. To evaluate reliability, two independent observers performed a thermography measurement of 50 burns. The intraclass correlation coefficient (ICC), the standard error of measurement (SEM), and the limits of agreement (LoA) were calculated. To assess validity, temperature differences between burned and nonburned skin (ΔT) were compared to the HP found by laser Doppler imaging (serving as the reference standard). By applying a visual method, one ΔT cutoff point was identified to differentiate between burns requiring conservative versus surgical treatment. The ICC was 0.99, expressing an excellent correlation between two measurements. The SEM was calculated at 0.22°C, the LoA at -0.58°C and 0.64°C. The ΔT cutoff point was -0.07°C (sensitivity 80% specificity 80%). These results show that thermography is a reliable and valid technique in the assessment of burn wound HP.

  2. Time-frequency analysis of laser Doppler flowmetry signals recorded in response to a progressive pressure applied locally on anaesthetized healthy rats

    Energy Technology Data Exchange (ETDEWEB)

    Humeau, Anne [Groupe ISAIP-ESAIP, 18 rue du 8 mai 1945, BP 80022, 49180 Saint Barthelemy d' Anjou Cedex (France); Koitka, Audrey [Laboratoire de Physiologie et d' Explorations Vasculaires, Centre Hospitalier Universitaire d' Angers, 49033 Angers Cedex 01 (France); Abraham, Pierre [Laboratoire de Physiologie et d' Explorations Vasculaires, Centre Hospitalier Universitaire d' Angers, 49033 Angers Cedex 01 (France); Saumet, Jean-Louis [Laboratoire de Physiologie et d' Explorations Vasculaires, Centre Hospitalier Universitaire d' Angers, 49033 Angers Cedex 01 (France); L' Huillier, Jean-Pierre [Ecole Nationale Superieure d' Arts et Metiers (ENSAM), Laboratoire Procedes-Materiaux-Instrumentation (LPMI), 2 boulevard du Ronceray, BP 3525, 49035 Angers Cedex (France)

    2004-03-07

    The laser Doppler flowmetry technique has recently been used to report a significant transient increase of the cutaneous blood flow signal, in response to a local non-noxious pressure applied progressively on the skin of both healthy humans and rats. This phenomenon is not entirely understood yet. In the present work, a time-frequency analysis is applied to signals recorded on anaesthetized healthy rats, at rest and during a cutaneous pressure-induced vasodilation (PIV). The comparison, at rest and during PIV, of the scalogram relative energies and scalogram relative amplitudes in five bands, corresponding to five characteristic frequencies, shows an increased contribution for the endothelial related metabolic activity in PIV signals, till 400 s after the beginning of the progressive pressure application. The other subsystems (heart, respiration, myogenic and neurogenic activities) contribute relatively less during PIV than at rest. The differences are statistically significant for all the relative activities in the interval 0-200 s following the beginning of the pressure. These results and others obtained on patients, such as diabetics, could increase the understanding of some cutaneous pathologies involved in various neurological diseases and in the pathophysiology of decubitus ulcers.

  3. Laser Doppler flowmetry: an early diagnosis instrument in detecting the soft tissue changes that occur during radiotherapy to the head and neck area, clinical case report

    Science.gov (United States)

    Petre, L. C.; Miron, M. I.; Ianes, E.

    2016-03-01

    Aim of the study: Our goal was to monitor soft tissue changes occurring during radiotherapy - both through clinical examination and using LDF - in order to establish Laser Doppler as an early diagnosis instrument in this situation, and also to assess what kind of dental procedures could be provided during radiotherapy, in order to increase patients' quality of life. Material and Method: Our study included two male patients, who received head and neck radiotherapy. Patient A, 68 years old, underwent 31 radiotherapy exposures. Patient B, 52 years old, underwent 24 exposures. They received a thorough clinical examination, and a LDF evaluation of gingival blood flow in areas close to the irradiated site, after the first, the 18th, and the last radiotherapy exposure. Results: Patient A presented radiotherapy induced mucositis, after the 18th radiotherapy exposure. After the last exposure the mucositis worsened, additionally, radiodermitis appeared on the neck. LDF showed an increase in blood flow of the irradiated area, even after the first exposure, and it persisted throughout treatment. Patient B showed no clinical changes, besides a hyperkeratinisation of the gingiva in the irradiated area, after the last exposure. LDF showed an overall increase in vascularity of the area throughout treatment. Discussion: Even after the first radiotherapy exposure, and also when clinical changes were not apparent, LDF measurements revealed an increase in blood flow in the gingiva of irradiated patients. LDF might allow us to establish the most appropriate moment in time for each dental treatment, in order to increase the quality of life.

  4. Changes in the spectral index of skin-surface laser Doppler signals of nude mice following the injection of CT26 tumor cells.

    Science.gov (United States)

    Liu, Ju-Chi; Hsiu, Hsin; Hsu, Yi-Ping; Tsai, Hung-Chi; Kuo, Chung-Hsien

    2016-01-01

    This study investigated microcirculatory-blood-flow responses in nude mice following the injection of CT26 tumor cells by analyzing the frequency content of skin blood-flow signals recorded on the skin surface. CT26 cells were injected subcutaneously (10^4/100 μl) into the right back flank of each 7-week-old mouse. Three-minute laser Doppler flowmetry (LDF) signals were measured in 60 nude mice. The data sequences were obtained at 1, 2, and 3 weeks after injecting CT26 cells. Mouse tissue samples were cut into sections and examined microscopically to determine the condition of cancer metastasis. Spectral analysis performed after 1 week revealed a significant decrease in the relative energy contribution of the endothelium-related frequency band, and significant increases in those of the myogenic and respiration-related frequency bands of the LDF signals in the metastasis group (n=12). To the best of our knowledge, this is the first study demonstrating the feasibility of evaluating metastasis in animal subjects based on changes in noninvasively measured LDF parameters. Changes in the LDF spectral indexes can be attributed to differences in the microcirculatory regulatory activities. The present measurements performed on the skin surface provide a noninvasive and real-time method for evaluating the microcirculatory responses induced by implanting CT26 tumor cells.

  5. Study of time reversibility/irreversibility of cardiovascular data: theoretical results and application to laser Doppler flowmetry and heart rate variability signals

    Science.gov (United States)

    Humeau-Heurtier, Anne; Mahé, Guillaume; Chapeau-Blondeau, François; Rousseau, David; Abraham, Pierre

    2012-07-01

    Time irreversibility can be qualitatively defined as the degree of a signal for temporal asymmetry. Recently, a time irreversibility characterization method based on entropies of positive and negative increments has been proposed for experimental signals and applied to heart rate variability (HRV) data (central cardiovascular system (CVS)). The results led to interesting information as a time asymmetry index was found different for young subjects and elderly people or heart disease patients. Nevertheless, similar analyses have not yet been conducted on laser Doppler flowmetry (LDF) signals (peripheral CVS). We first propose to further investigate the above-mentioned characterization method. Then, LDF signals, LDF signals reduced to samples acquired during ECG R peaks (LDF_RECG signals) and HRV recorded simultaneously in healthy subjects are processed. Entropies of positive and negative increments for LDF signals show a nonmonotonic pattern: oscillations—more or less pronounced, depending on subjects—are found with a period matching the one of cardiac activity. However, such oscillations are not found with LDF_RECG nor with HRV. Moreover, the asymmetry index for LDF is markedly different from the ones of LDF_RECG and HRV. The cardiac activity may therefore play a dominant role in the time irreversibility properties of LDF signals.

  6. [Blood perfusion in different facial acupoint areas and its changes after acupuncture stimulation of Hegu (LI 4) displayed by laser Doppler imager in healthy volunteers].

    Science.gov (United States)

    Wang, Shu-You; Qu, Xiao-Xiao; Song, Xiao-Jing; Li, Shun-Yue; Ma, Hui-Min; Zhang, Dong

    2012-12-01

    To observe the blood perfusion levels in different facial acupoint regions and changes after acupuncture stimulation of Hegu (LI 4). Thirty healthy volunteer subjects were equally divided into control group and acupuncture group. Blood perfusion levels of different facial acupoint areas were detected using a Laser Doppler Imager. Acupuncture stimulation was applied to bilateral Hegu (LI 4) by using two filiform needles which were manipulated for a while till "Deqi", followed by keeping them in position for 30 min. The needles were then manipulated once again every 10 min. The blood perfusion levels of facial acupoint regions were from 0.73 to 1.17 PU in healthy volunteers, with relatively higher levels being in Juliao (ST 3), Kouheliao (LI 19), Sibai (ST 2) and Chengqi (ST 1) regions and relatively lower levels in Xiaguan (ST 7), Qianzheng (Ex-HN) and Sizhukong (TE 23) regions, but without significant difference between the isonym acupoint areas of the bilateral face in the control group. Following acupuncture stimulation of bilateral Hegu (LI 4), the blood perfusion volumes were remarkably increased in the acupoint regions on bilateral sides of the face (P < 0.05, P < 0.01). Acupuncture of Hegu (LI 4) can effectively increase blood perfusion volume of the acupoint areas of the bilateral face in healthy volunteers.

  7. Monitoring hypoxia induced changes in cochlear blood flow and hemoglobin concentration using a combined dual-wavelength laser speckle contrast imaging and Doppler optical microangiography system.

    Directory of Open Access Journals (Sweden)

    Roberto Reif

    Full Text Available A synchronized dual-wavelength laser speckle contrast imaging (DWLSCI system and a Doppler optical microangiography (DOMAG system was developed to determine several ischemic parameters in the cochlea due to a systemic hypoxic challenge. DWLSCI can obtain two-dimensional data, and was used to determine the relative changes in cochlear blood flow, and change in the concentrations of oxyhemoglobin (HbO, deoxyhemoglobin (Hb and total hemoglobin (HbT in mice. DOMAG can obtain three-dimensional data, and was used to determine the changes in cochlear blood flow with single vessel resolution. It was demonstrated that during a hypoxic challenge there was an increase in the concentrations of Hb, a decrease in the concentrations of HbO and cochlear blood flow, and a slight decrease in the concentration of HbT. Also, the rate of change in the concentrations of Hb and HbO was quantified during and after the hypoxic challenge. The ability to simultaneously measure these ischemic parameters with high spatio-temporal resolution will allow the detailed quantitative analysis of several hearing disorders, and will be useful for diagnosing and developing treatments.

  8. Simulations and Measurements of Human Middle Ear Vibrations Using Multi-Body Systems and Laser-Doppler Vibrometry with the Floating Mass Transducer

    Directory of Open Access Journals (Sweden)

    Tobias Strenger

    2013-10-01

    Full Text Available The transfer characteristic of the human middle ear with an applied middle ear implant (floating mass transducer is examined computationally with a Multi-body System approach and compared with experimental results. For this purpose, the geometry of the middle ear was reconstructed from μ-computer tomography slice data and prepared for a Multi-body System simulation. The transfer function of the floating mass transducer, which is the ratio of the input voltage and the generated force, is derived based on a physical context. The numerical results obtained with the Multi-body System approach are compared with experimental results by Laser Doppler measurements of the stapes footplate velocities of five different specimens. Although slightly differing anatomical structures were used for the calculation and the measurement, a high correspondence with respect to the course of stapes footplate displacement along the frequency was found. Notably, a notch at frequencies just below 1 kHz occurred. Additionally, phase courses of stapes footplate displacements were determined computationally if possible and compared with experimental results. The examinations were undertaken to quantify stapes footplate displacements in the clinical practice of middle ear implants and, also, to develop fitting strategies on a physical basis for hearing impaired patients aided with middle ear implants.

  9. Effects of intracranial pressure on the pial microcirculation in rats studied by a fiber-optic laser-Doppler anemometer microscope.

    Science.gov (United States)

    Seki, J; Sasaki, Y; Oyama, T; Yamamoto, J

    1999-01-01

    The fiber-optic laser-Doppler anemometer microscope (FLDAM) developed in our laboratory was applied to measure red cell velocity in individual pial microvessels in rats to determine the effect of intracranial pressure (ICP) on the pial microcirculation. The red cell velocity and the vessel diameter of pial microvessels were measured through a closed cranial window at controlled values of ICP between 0 and 50 mmHg. As ICP increased from 0 to 50 mmHg, the average relative diameter of venules with respect to the diameter at an ICP of 5 mmHg decreased from 1.18 +/- 0.12 (mean +/- SD) to 0.74 +/- 0.08 and the average relative velocity increased from 0.80 +/- 0.20 to 1.83 +/- 0.42 monotonically. The changes in diameter and velocity of arterioles with ICP were small, and they were not significantly different from those values at an ICP of 5 mmHg except for the diameter at an ICP of 20 mmHg. The mean volume flow rates calculated assuming a circular vessel cross-section did not show any statistically significant change with ICP between 0 and 50 mmHg in both arterioles and venules, which supports the concept of autoregulation.

  10. Dynamic testing of MEMS based on laser doppler effect%基于激光多普勒效应的MEMS的运动检测

    Institute of Scientific and Technical Information of China (English)

    侯世博; 李醒飞; 贺少辉

    2009-01-01

    A system for testing transient velocities and displacements of MEMS is proposed. The system is based on differential laser Doppler effect. Frequency shift technology and wave filtering technology are used to process the signal and software Lab VIEW & Matlab are used to measure its moveme t parameters with the mothed of digital filtering technology and time-frequency analysis. An accurate and reliable method can be provided for the research on dynamic characteristics of MEMS.%提出了一种可以测量微机电系统(MEMS)面内瞬时速度和位移的测量系统.该系统利用差动激光多普勒效应,采用了频移技术和接收端的滤波技术将带有MEMS运动信息的光信号接收并解调,然后,利用LabVIEW和Matlab软件对采集的信号进行数字滤波和时频分析,从而得到被测器件的运动参量,为研究MEMS的动态特性提供了准确可靠的方法.

  11. Objective assessment of topical anti-inflammatory drug activity on experimentally induced nickel contact dermatitis: comparison between visual scoring, colorimetry, laser Doppler velocimetry and transepidermal water loss.

    Science.gov (United States)

    Queille-Roussel, C; Duteil, L; Padilla, J M; Poncet, M; Czernielewski, J

    1990-01-01

    Four topical anti-inflammatory drugs were investigated for their effect on allergic contact dermatitis. Nickel dermatitis was chosen for its high incidence in European healthy volunteers. Experimental lesions were treated twice daily with two steroids, two non-steroidal anti-inflammatory drugs and a blank base for 4.5 days without occlusion. The influence of treatments was assessed by daily visual grading and one site was left untreated for comparison over the same period. To quantify drug activities objectively, skin colour (colorimetry), skin blood flow (laser Doppler velocimetry) and transepidermal water loss (evaporimetry) were measured before drugs were first applied, then 6 hr after the last application. As expected, only Dermoval cream significantly improved the spontaneous clinical evolution in comparison with the other creams (Hydrocortisone Aster à 1%. Parfenac, indomethacin 2.5% and Skinbase) and the untreated site. Colorimetric parameter a* (redness) and L* (luminance) showed more differences between treatments than the other criteria and a close relationship was obtained between these two parameters and skin blood flow, all three being highly correlated to visual grading. Transepidermal water loss appeared less related to clinical improvement but this parameter could prove helpful for detecting compounds which could be irritant to diseased skin.

  12. Local cooling reduces skin ischemia under surface pressure in rats: an assessment by wavelet analysis of laser Doppler blood flow oscillations.

    Science.gov (United States)

    Jan, Yih-Kuen; Lee, Bernard; Liao, Fuyuan; Foreman, Robert D

    2012-10-01

    The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using the wavelet analysis of blood flow oscillations in rats. Twelve Sprague-Dawley rats were randomly assigned to three protocols, including pressure with local cooling (Δt = -10 °C), pressure with local heating (Δt = 10 °C) and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin blood flow was measured using laser Doppler flowmetry. The 3 h loading period was divided into non-overlapping 30 min epochs for the analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased under the conditions of pressure with heating and of pressure without temperature changes, but maintained stable under the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers.

  13. The use of spectral skin reflectivity and laser doppler vibrometry data to determine the optimal site and wavelength to collect human vital sign signatures

    Science.gov (United States)

    Byrd, Kenneth A.; Kaur, Balvinder; Hodgkin, Van A.

    2012-06-01

    The carotid artery has been used extensively by researchers to demonstrate that Laser Doppler Vibrometry (LDV) is capable of exploiting vital sign signatures from cooperative human subjects at stando. Research indicates that, the carotid, although good for cooperative and non-traumatic scenarios, is one of the first vital signs to become absent or irregular when a casualty is hemorrhaging and in progress to circulatory (hypovolemic) shock. In an effort to determine the optimal site and wavelength to measure vital signs off human skin, a human subject data collection was executed whereby 14 subjects had their spectral skin reflectivity and vital signs measured at five collection sites (carotid artery, chest, back, right wrist and left wrist). In this paper, we present our findings on using LDV and re ectivity data to determine the optimal collection site and wavelength that should be used to sense pulse signals from quiet and relatively motionless human subjects at stando. In particular, we correlate maximum levels of re ectivity across the ensemble of 14 subjects with vital sign measurements made with an LDV at two ranges, for two scenarios.

  14. Multi-mode fibre laser Doppler anemometer (LDA) with high spatial resolution for the investigation of boundary layers

    Energy Technology Data Exchange (ETDEWEB)

    Buettner, L.; Czarske, J. [Group Laser Metrology, Laser Zentrum Hannover e.V., Hollerithallee 8, 30419, Hannover (Germany)

    2004-01-01

    A novel LDA system using laser diode arrays and multi-mode fibers in the transmitting optics is presented. The use of high numerical aperture multi-mode step-index fibres results in measurement volumes with, for example, 80 {mu}m length and minimal speckle effects. Because of the high spatial resolution and low relative fringe spacing variation of {delta}d/d{approx}5 x 10{sup -4} the multi-mode fibre LDA is predestined for investigating turbulent flows. Boundary layer measurements carried out show excellent agreement with theoretical velocity profiles. (orig.)

  15. Photoacoustic Doppler effect from flowing small light-absorbing particles.

    Science.gov (United States)

    Fang, Hui; Maslov, Konstantin; Wang, Lihong V

    2007-11-01

    From the flow of a suspension of micrometer-scale carbon particles, the photoacoustic Doppler shift is observed. As predicted theoretically, the observed Doppler shift equals half of that in Doppler ultrasound and does not depend on the direction of laser illumination. This new physical phenomenon provides a basis for developing photoacoustic Doppler flowmetry, which can potentially be used for detecting fluid flow in optically scattering media and especially low-speed blood flow of relatively deep microcirculation in biological tissue.

  16. Implementation of Two Component Advective Flow Solution in XSPEC

    CERN Document Server

    Debnath, Dipak; Mondal, Santanu

    2014-01-01

    Spectral and Temporal properties of black hole candidates can be explained reasonably well using Chakrabarti-Titarchuk solution of two component advective flow (TCAF). This model requires two accretion rates, namely, the Keplerian disk accretion rate and the halo accretion rate, the latter being composed of a sub-Keplerian, low angular momentum flow which may or may not develop a shock. In this solution, the relevant parameter is the relative importance of the halo (which creates the Compton cloud region) rate with respect to the Keplerian disk rate (soft photon source). Though this model has been used earlier to manually fit data of several black hole candidates quite satisfactorily, for the first time, we made it user friendly by implementing it into XSPEC software of GSFC/NASA. This enables any user to extract physical parameters of the accretion flows, such as two accretion rates, the shock location, the shock strength etc. for any black hole candidate. We provide some examples of fitting a few cases usin...

  17. Dynamical principles of two-component genetic oscillators.

    Directory of Open Access Journals (Sweden)

    Raúl Guantes

    2006-03-01

    Full Text Available Genetic oscillators based on the interaction of a small set of molecular components have been shown to be involved in the regulation of the cell cycle, the circadian rhythms, or the response of several signaling pathways. Uncovering the functional properties of such oscillators then becomes important for the understanding of these cellular processes and for the characterization of fundamental properties of more complex clocks. Here, we show how the dynamics of a minimal two-component oscillator is drastically affected by its genetic implementation. We consider a repressor and activator element combined in a simple logical motif. While activation is always exerted at the transcriptional level, repression is alternatively operating at the transcriptional (Design I or post-translational (Design II level. These designs display differences on basic oscillatory features and on their behavior with respect to molecular noise or entrainment by periodic signals. In particular, Design I induces oscillations with large activator amplitudes and arbitrarily small frequencies, and acts as an "integrator" of external stimuli, while Design II shows emergence of oscillations with finite, and less variable, frequencies and smaller amplitudes, and detects better frequency-encoded signals ("resonator". Similar types of stimulus response are observed in neurons, and thus this work enables us to connect very different biological contexts. These dynamical principles are relevant for the characterization of the physiological roles of simple oscillator motifs, the understanding of core machineries of complex clocks, and the bio-engineering of synthetic oscillatory circuits.

  18. Hamiltonian of a homogeneous two-component plasma.

    Science.gov (United States)

    Essén, Hanno; Nordmark, A

    2004-03-01

    The Hamiltonian of one- and two-component plasmas is calculated in the negligible radiation Darwin approximation. Since the Hamiltonian is the phase space energy of the system its form indicates, according to statistical mechanics, the nature of the thermal equilibrium that plasmas strive to attain. The main issue is the length scale of the magnetic interaction energy. In the past a screening length lambda=1/square root of r(e)n], with n number density and r(e) classical electron radius, has been derived. We address the question whether the corresponding longer screening range obtained from the classical proton radius is physically relevant and the answer is affirmative. Starting from the Darwin Lagrangian it is nontrivial to find the Darwin Hamiltonian of a macroscopic system. For a homogeneous system we resolve the difficulty by temporarily approximating the particle number density by a smooth constant density. This leads to Yukawa-type screened vector potential. The nontrivial problem of finding the corresponding, divergence free, Coulomb gauge version is solved.

  19. A minimal model for two-component dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Esch, Sonja; Klasen, Michael; Yaguna, Carlos E. [Institut fuer theoretische Physik, Universitaet Muenster, Wilhelm-Klemm-Strasse 9,D-48149 Muenster (Germany)

    2015-07-01

    We propose and study a new minimal model for two-component dark matter. The model contains only three additional fields, one fermion and two scalars, all singlets under the Standard Model gauge group. Two of these fields, one fermion and one scalar, are odd under a Z{sub 2} symmetry that renders them simultaneously stable. Thus, both particles contribute to the observed dark matter density. This model resembles the union of the singlet scalar and the singlet fermionic models but it contains some new features of its own. We analyze in some detail its dark matter phenomenology. Regarding the relic density, the main novelty is the possible annihilation of one dark matter particle into the other, which can affect the predicted relic density in a significant way. Regarding dark matter detection, we identify a new contribution that can lead either to an enhancement or to a suppression of the spin-independent cross section for the scalar dark matter particle. Finally, we define a set of five benchmarks models compatible with all present bounds and examine their direct detection prospects at planned experiments. A generic feature of this model is that both particles give rise to observable signals in 1-ton direct detection experiments. In fact, such experiments will be able to probe even a subdominant dark matter component at the percent level.

  20. A minimal model for two-component dark matter

    CERN Document Server

    Esch, Sonja; Yaguna, Carlos E

    2014-01-01

    We propose and study a new minimal model for two-component dark matter. The model contains only three additional fields, one fermion and two scalars, all singlets under the Standard Model gauge group. Two of these fields, one fermion and one scalar, are odd under a $Z_2$ symmetry that renders them simultaneously stable. Thus, both particles contribute to the observed dark matter density. This model resembles the union of the singlet scalar and the singlet fermionic models but it contains some new features of its own. We analyze in some detail its dark matter phenomenology. Regarding the relic density, the main novelty is the possible annihilation of one dark matter particle into the other, which can affect the predicted relic density in a significant way. Regarding dark matter detection, we identify a new contribution that can lead either to an enhancement or to a suppression of the spin-independent cross section for the scalar dark matter particle. Finally, we define a set of five benchmarks models compatibl...

  1. A minimal model for two-component dark matter

    Science.gov (United States)

    Esch, Sonja; Klasen, Michael; Yaguna, Carlos E.

    2014-09-01

    We propose and study a new minimal model for two-component dark matter. The model contains only three additional fields, one fermion and two scalars, all singlets under the Standard Model gauge group. Two of these fields, one fermion and one scalar, are odd under a Z 2 symmetry that renders them simultaneously stable. Thus, both particles contribute to the observed dark matter density. This model resembles the union of the singlet scalar and the singlet fermionic models but it contains some new features of its own. We analyze in some detail its dark matter phenomenology. Regarding the relic density, the main novelty is the possible annihilation of one dark matter particle into the other, which can affect the predicted relic density in a significant way. Regarding dark matter detection, we identify a new contribution that can lead either to an enhancement or to a suppression of the spin-independent cross section for the scalar dark matter particle. Finally, we define a set of five benchmarks models compatible with all present bounds and examine their direct detection prospects at planned experiments. A generic feature of this model is that both particles give rise to observable signals in 1-ton direct detection experiments. In fact, such experiments will be able to probe even a subdominant dark matter component at the percent level.

  2. Two-component perfect fluid in FRW universe

    CERN Document Server

    ,

    2012-01-01

    We propose the cosmological model which allows to describe on equal footing the evolution of matter in the universe on the time interval from the inflation till the domination of dark energy. The matter is considered as a two-component perfect fluid imitated by homogeneous scalar fields between which there is energy exchange. Dark energy is represented by the cosmological constant, which is supposed invariable during the whole evolution of the universe. The matter changes its equation of state with time, so that the era of radiation domination in the early universe smoothly passes into the era of a pressureless gas, which then passes into the late-time epoch, when the matter is represented by a gas of low-velocity cosmic strings. The inflationary phase is described as an analytic continuation of the energy density in the very early universe into the region of small negative values of the parameter which characterizes typical time of energy transfer from one matter component to another. The Hubble expansion ra...

  3. Two component systems: physiological effect of a third component.

    Directory of Open Access Journals (Sweden)

    Baldiri Salvado

    Full Text Available Signal transduction systems mediate the response and adaptation of organisms to environmental changes. In prokaryotes, this signal transduction is often done through Two Component Systems (TCS. These TCS are phosphotransfer protein cascades, and in their prototypical form they are composed by a kinase that senses the environmental signals (SK and by a response regulator (RR that regulates the cellular response. This basic motif can be modified by the addition of a third protein that interacts either with the SK or the RR in a way that could change the dynamic response of the TCS module. In this work we aim at understanding the effect of such an additional protein (which we call "third component" on the functional properties of a prototypical TCS. To do so we build mathematical models of TCS with alternative designs for their interaction with that third component. These mathematical models are analyzed in order to identify the differences in dynamic behavior inherent to each design, with respect to functionally relevant properties such as sensitivity to changes in either the parameter values or the molecular concentrations, temporal responsiveness, possibility of multiple steady states, or stochastic fluctuations in the system. The differences are then correlated to the physiological requirements that impinge on the functioning of the TCS. This analysis sheds light on both, the dynamic behavior of synthetically designed TCS, and the conditions under which natural selection might favor each of the designs. We find that a third component that modulates SK activity increases the parameter space where a bistable response of the TCS module to signals is possible, if SK is monofunctional, but decreases it when the SK is bifunctional. The presence of a third component that modulates RR activity decreases the parameter space where a bistable response of the TCS module to signals is possible.

  4. Absolutely stable solitons in two-component active systems

    CERN Document Server

    Malomed, B A; Malomed, Boris; Winful, Herbert

    1995-01-01

    As is known, a solitary pulse in the complex cubic Ginzburg-Landau (GL) equation is unstable. We demonstrate that a system of two linearly coupled GL equations with gain and dissipation in one subsystem and pure dissipation in another produces absolutely stable solitons and their bound states. The problem is solved in a fully analytical form by means of the perturbation theory. The soliton coexists with a stable trivial state; there is also an unstable soliton with a smaller amplitude, which is a separatrix between the two stable states. This model has a direct application in nonlinear fiber optics, describing an Erbium-doped laser based on a dual-core fiber.

  5. Two-Component Signal Transduction System SaeRS Positively Regulates Staphylococcus epidermidis Glucose Metabolism

    Directory of Open Access Journals (Sweden)

    Qiang Lou

    2014-01-01

    Full Text Available Staphylococcus epidermidis, which is a causative pathogen of nosocomial infection, expresses its virulent traits such as biofilm and autolysis regulated by two-component signal transduction system SaeRS. In this study, we performed a proteomic analysis of differences in expression between the S. epidermidis 1457 wild-type and saeRS mutant to identify candidates regulated by saeRS using two-dimensional gel electrophoresis (2-DE combined with matrix-assisted laser desorption/lonization mass spectrometry (MALDI-TOF-MS. Of 55 identified proteins that significantly differed in expression between the two strains, 15 were upregulated and 40 were downregulated. The downregulated proteins included enzymes related to glycolysis and TCA cycle, suggesting that glucose is not properly utilized in S. epidermidis when saeRS was deleted. The study will be helpful for treatment of S. epidermidis infection from the viewpoint of metabolic modulation dependent on two-component signal transduction system SaeRS.

  6. Testing relativity again, laser, laser, laser, laser

    NARCIS (Netherlands)

    Einstein, A.

    2015-01-01

    laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser, laser,

  7. PREPARATION OF PUZZOLANA ACTIVE TWO COMPONENT COMPOSITE FOR LATENT HEAT STORAGE

    Directory of Open Access Journals (Sweden)

    Jan Fort

    2016-10-01

    Full Text Available Application of Phase Change Materials (PCMs represents promising way for an increase of energy efficiency of industrial devices, reduction of energy demands for heating and cooling, waste heat recovery, solar energy storage and smart control of buildings interior climate. In this paper, the potential of diatomite as the bearer for the shape stable PCM was studied in order to develop material applicable in the mix composition of composite materials. Considering availability, endurance and compatibility of diatomite with the cement and lime based materials, preparation of diatomite/wax composite brings pozzolana active PCM with great promises at a reasonable cost. Prepared composite was analysed in detail using laser diffraction, scanning electron microscopy, Fourier transform infrared spectroscopy and differential scanning calorimetry. Also the pozzolanic activity was measured. The prepared two components composite exhibits high latent heat storage and particle size distribution compatible with cement and hydrated lime.

  8. The Fractional Virial Potential Energy in Two-Component Systems

    Directory of Open Access Journals (Sweden)

    Caimmi, R.

    2008-12-01

    Full Text Available Two-component systems are conceived as macrogases, and the related equation of state is expressed using the virial theorem for subsystems, under the restriction of homeoidally striated density profiles. Explicit calculations are performed for a useful reference case and a few cases of astrophysical interest, both with and without truncation radius. Shallower density profiles are found to yield an equation of state, $phi=phi(y,m$, characterized (for assigned values of the fractional mass, $m=M_j/ M_i$ by the occurrence of two extremum points, a minimum and a maximum, as found in an earlier attempt. Steeper density profiles produce a similar equation of state, which implies that a special value of $m$ is related to a critical curve where the above mentioned extremum points reduce to a single horizontal inflexion point, and curves below the critical one show no extremum points. The similarity of the isofractional mass curves to van der Waals' isothermal curves, suggests the possibility of a phase transition in a bell-shaped region of the $({sf O}yphi$ plane, where the fractional truncation radius along a selected direction is $y=R_j/R_i$, and the fractional virial potential energy is $phi=(E_{ji}_mathrm{vir}/(E_{ij}_mathrm{vir}$. Further investigation is devoted to mass distributions described by Hernquist (1990 density profiles, for which an additional relation can be used to represent a sample of $N=16$ elliptical galaxies (EGs on the $({sf O}yphi$ plane. Even if the evolution of elliptical galaxies and their hosting dark matter (DM haloes, in the light of the model, has been characterized by equal fractional mass, $m$, and equal scaled truncation radius, or concentration, $Xi_u=R_u/r_u^dagger$, $u=i,j$, still it cannot be considered as strictly homologous, due to different values of fractional truncation radii, $y$, or fractional scaling radii, $y^dagger=r_j^dagger/r_i^dagger$, deduced from sample objects.

  9. Full report of laser doppler velocimetry (Het-V) data, results , and analysis for pRad shot 0632

    Energy Technology Data Exchange (ETDEWEB)

    Tupa, Dale [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tainter, Amy Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-21

    This was a collaborative shot with AWE investigators Paul Willis-Patel, David Bell, Seth Grant, David Tarr, and James Richley. The shot was assembled in Los Alamos, after which David Bell set up the probe holder and finalized the alignment. The probe holder location and configuration was modified from previous years to make room for the laser illuminated visible imaging diagnostic. The LANL pRad PDV team was Dale Tupa, Amy Tainter, and Patrick Medina. This shot had three PDV probes: one aimed at the center, one aimed at a feature, one aimed at the reverse side of the shot. The shot also had 9 points of a spectroscopy diagnostic. The pRad team helped set up and field the spectroscopy, but did not help with any data analysis. (The support documentation for the PDV results includes a timing map for the spectroscopy.) Please direct questions on the velocimetry to Dale Tupa or Amy Tainter. The shot radiographs were classified, but the data from the optical diagnostics are not.

  10. Assessing the Effects of Acupuncture by Comparing Needling the Hegu Acupoint and Needling Nearby Nonacupoints by Spectral Analysis of Microcirculatory Laser Doppler Signals

    Directory of Open Access Journals (Sweden)

    Hsin Hsiu

    2011-01-01

    Full Text Available We aimed to assess the effects of acupuncture by analyzing the frequency content of skin blood-flow signals simultaneously recorded at the Hegu acupoint and two nearby nonacupoints following acupuncture stimulation (AS. Laser Doppler flowmetry (LDF signals were measured in male healthy volunteers in two groups of experiments: needling the Hegu acupoint (n = 13 and needling a nearby nonacupoint (control experiment; n = 10. Each experiment involved recording a 20 min baseline-data sequence and two sets of effects data recorded 0–20 and 50–70 min after stopping AS. Wavelet transform with Morlet mother wavelet was applied to the measured LDF signals. Needling the Hegu acupoint significantly increased the blood flow, significantly decreased the relative energy contribution at 0.02–0.06 Hz and significantly increased the relative energy contribution at 0.4–1.6 Hz at Hegu, but induced no significant changes at the nonacupoints. Also, needling a nearby nonacupoint had no effect in any band at any site. This is the first time that spectral analysis has been used to investigate the microcirculatory blood-flow responses induced by AS, and has revealed possible differences in sympathetic nerve activities between needling the Hegu acupoint and its nearby nonacupoint. One possible weakness of the present design is that different De-Qi feelings following AS could lead to nonblind experimental setup, which may bias the comparison between needling Hegu and its nearby nonacupoint. Our results suggest that the described noninvasive method can be used to evaluate sympathetic control of peripheral vascular activity, which might be useful for studying the therapeutic effects of AS.

  11. Relationship between media-to-lumen ratio of subcutaneous small arteries and wall-to-lumen ratio of retinal arterioles evaluated noninvasively by scanning laser Doppler flowmetry.

    Science.gov (United States)

    Rizzoni, Damiano; Porteri, Enzo; Duse, Sarah; De Ciuceis, Carolina; Rosei, Claudia Agabiti; La Boria, Elisa; Semeraro, Francesco; Costagliola, Ciro; Sebastiani, Adolfo; Danzi, Paola; Tiberio, Guido A M; Giulini, Stefano M; Docchio, Franco; Sansoni, Giovanna; Sarkar, Annamaria; Rosei, Enrico Agabiti

    2012-06-01

    Structural alterations of subcutaneous small resistance arteries, as indicated by an increased media-to-lumen ratio, are frequently present in hypertensive and/or diabetic patients, and may represent the earliest alteration observed. Furthermore, media-to-lumen ratio of small arteries evaluated by micromyography has a strong prognostic significance; however, its extensive evaluation is limited by the invasivity of the assessment, since a biopsy of subcutaneous fat is needed. Noninvasive measurement of wall-to-lumen of retinal arterioles using scanning laser Doppler flowmetry (SLDF) has recently been introduced. However, this new technique has not yet been compared to micromyographic measurement, generally considered the gold standard approach. We investigated 40 individuals and patients, 24 of them were hypertensive patients and 16 normotensive individuals. All patients underwent a biopsy of subcutaneous fat during an elective surgical intervention. Subcutaneous small resistance arteries were dissected and mounted on a wire myograph, and media-to-lumen ratio was measured. In addition, an evaluation of wall-to-lumen ratio of retinal arterioles by SLDF was performed (Heidelberg Retina Flowmeter, Heidelberg Engineering). A close correlation was observed between media-to-lumen ratio of subcutaneous small arteries and wall-to-lumen ratio of retinal arterioles (r = 0.76, P < 0.001; P < 0.001, r(2) = 0.57). A noninvasive and easily repeatable procedure (intraobserver and interobserver variation coefficient <13%) such as an evaluation of the arterioles in the fundus oculi by SLDF may provide similar information regarding microvascular morphology compared with an invasive, accurate and prognostically relevant micromyographic measurement of media-to-lumen ratio of subcutaneous small arteries.

  12. Laser Doppler flowmeter study on regional cerebral blood flow in early stage after standard superficial temporal artery-middle cerebral artery bypass surgery for moyamoya disease

    Institute of Scientific and Technical Information of China (English)

    GESANG Dun-zhu; ZHANG Dong; ZHAO Ji-zong; WANG Shuo; ZHAO Yuan-li; WANG Rong; SUN Jian-jun; MENG Ze

    2009-01-01

    Background Standard superficial temporal artery-middle cerebral artery (STA-MCA) bypass surgery is an effective treatment for moyamoya disease, but recent evidence suggests that postoperative cerebral hyperperfusion can occur. In this study, the trendline of changes in regional cerebral blood flow (rCBF) after surgery were continually monitored near the site of anastomosis in order to investigate both the efficacy of the procedure for improving rCBF and the possible riskof hyperperfusion.Methods Standard STA-MCA bypass surgery was performed on 13 patients, rCBF was measured continually using laser Doppler flowmetry (LDF) until the 5th day after the operation with the LDF probe implanted adjacent to the area of the anastomosis. The trendline of rCBF changes postoperatively was recorded for the analysis performed using SPSS 13.0.Results The baseline LDF value of cortical rCBF was (84.68±14.39) perfusion unit (PU), which was linear relative to absolute perfusion volume before anastomosis and (88.90±11.26) PU immediately after anastomosis (P >0.05). The value changed significantly from before to after anastomosis (P 0.05).Conclusions STA-MCA anastomosis improves the cerebral blood supply significantly in the early stage after surgery,however, the risk of symptomatic hyperperfusion may exist, which may possibly occur on the 1st day and 5th day after surgery. A LDF is useful for postoperative monitoring for both the efficacy of bypass and possible risk of neurologic deterioration or bleeding from hyperperfusion.

  13. Advances in the research of laser Doppler perfusion imaging in burn wounds%激光多普勒血流灌注成像在烧伤创面中的应用研究进展

    Institute of Scientific and Technical Information of China (English)

    刘晶; 许龙顺; 胡大海; 屈怡; 王国栋; 王洪涛

    2014-01-01

    Laser Doppler perfusion imaging (LDPI)works through the Doppler effect of light wave,and it could depict the blood flow value of the entire wound in two-dimensional image without contacting the detection site directly.In resent years,LDPI has been proved to be effective to evaluate healing potential of a wound,and to predict burn depth and scar formation.The accuracy of LDPI is higher than other traditional methods and technique.However,there are still many influencing factors for the clinical application of LDPI scanning.This paper presents a comprehensive overview of advances in the research of LDPI for clinical application in the care of burn wounds and influencing factors for accurate scanning.

  14. The doppler ultrasound. La ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Contreras Cecilia, E.; Lozano Setien, E.; Hernandez Montero, J.; Ganado Diaz, T.; Jorquera Moya, M.; Blasco Pascual, E. (Hospital Universitario San Carlos. Madrid (Spain))

    1994-01-01

    The discovery and development of Doppler ultrasound has had a great influence on Medical practice since it allows the noninvasive study of vascular pathology, both arterial and venous, as well as the flow patterns of the different parenchyma. This article deals with the principles, limitations and interpretation of the Doppler signal, as well as the different Doppler ultrasound systems routinely employed in Medicine.

  15. Study of the functional state of peripheral vessels in fingers of rheumatological patients by means of laser Doppler flowmetry and cutaneous thermometry measurements

    Science.gov (United States)

    Zherebtsova, Angelina I.; Zherebtsov, Evgeny A.; Dunaev, Andrey V.; Podmasteryev, Konstantin V.; Pilipenko, Olga V.; Krupatkin, Alexander I.; Khakhicheva, Lyudmila S.; Muradyan, Vadim F.

    2016-04-01

    Vasospastic disorders are a common class of rheumatic disease. These include syndromes such as vegetative dystonia, Raynaud's syndrome, vibration disease and rheumatoid arthritis among others. The aim of this work is to develop an original method of diagnosing the functional state of peripheral vessels of the fingers, based on the simultaneous recording of LDF- and thermograms during the occlusion test, for determining vascular disorders of rheumatological patients. A diagnostic method was developed for assessing the functional state of the peripheral vessels of fingers, based on carrying out occlusion test in a thermally stabilized environment, with simultaneous recording of signals of laser Doppler flowmetry and skin thermometry. To verify the diagnostic value of the proposed method, a series of experiments were carried out on 41 rheumatological patients: 5 male and 36 females (average age 56.0+/-12.2 years). The most common diagnoses in the patient group were rheumatoid arthritis, arthrosis, gout and systemic lupus erythematosus. The laser analyser of blood microcirculation "LAKK-02" (SPE "LAZMA" Ltd, Russia) and a custom developed multi-channel thermometry device for low inertia thermometry were used for experimental measurements. The measurements of cutaneous temperature and the index of microcirculation were performed on the distal phalanx of the third finger of the right hand. Occlusion tests were performed with water baths at 25 and 42 °C and a tonometer cuff with a pressure of 200-220 mmHg for 3 min on the upper arm. The results of experimental studies are presented and interpreted. These data indicate a violation of the blood supply regulation in the form of a pronounced tendency towards microvascular vasoconstriction in the fingers. Thus, the response displaying a tendency toward angiospasm among patients in the rheumatological diseases profile group was observed mainly in the most severe cases (49 % of this group). The prospects of the developed

  16. Heat transfer in two-component internal mist cooling

    Energy Technology Data Exchange (ETDEWEB)

    Novak, V.; Sadowski, D.L.; Schoonover, K.G.; Abdel-Khalik, S.I. [G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30332-0405 (United States); Ghiaasiaan, S.M. [G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30332-0405 (United States)], E-mail: mghiaasiaan@gatech.edu

    2008-09-15

    An experimental investigation was conducted to examine steady, internal, nozzle-generated, gas/liquid mist cooling in vertical channels. The ideal primary cooling mechanism in this situation is surface evaporation of an ultra-thin, subcooled liquid film that forms on the heated surface. The aim was to quantify the effects of various operating and design parameters on the cooling effectiveness. Parameters tested included the liquid atomization nozzle design, inlet flow condition (liquid mass fraction; carrier gas velocity, temperature and humidity; liquid temperature; liquid droplet size distribution; and gas/liquid combination), channel characteristics (cross-section geometry, length and surface wettability), and flow direction. Interest in this research has been motivated by the need for a highly efficient cooling mechanism in high-power lasers for inertial fusion reactor applications. A fully instrumented experimental test facility that included three cylindrical and two rectangular electrically heated test sections with different cross-sections and unheated entry lengths was used. The channel hydraulic diameters covered the range 16-26.7 mm, and the heated length-to-hydraulic-diameter ratio varied in the range from 23.3 to 51. Water was used as the mist liquid, with air or helium as the carrier gas. Three types of mist generating nozzles with significantly different spray characteristics were used. Local heat transfer coefficients, defined based on the temperature difference between the heated surface and the bulk gas, were obtained along the channels for a wide range of operating conditions. The data indicate that mist cooling can increase the heat transfer coefficient by more than an order of magnitude compared to forced convection using only the carrier gas.

  17. Study on Identification of Error for the NC Machine Tools Based on Laser Doppler Anemometer%基于激光多普勒仪的数控机床误差辨识

    Institute of Scientific and Technical Information of China (English)

    甘彬; 刘洋; 赵宇

    2013-01-01

    In response to laser Doppler anemometer characteristics of high precision linear displacement measurement of CNC machine tools, this paper introduced the use of laser Doppler anemometer on the NC machine tool error detection and identification method, explained the identification principle in detail and set up the method of error detection model. In order to reduce the machine error, we provide measurement method and basis of the compensation.%针对激光多普勒仪对数控机床线位移测量精度高的特点,介绍了利用激光多普勒仪对数控机床进行误差检测和辨识的方法,阐述了该方法的几何误差辨识原理,并建立了基于该方法的误差检测数学模型.为减小机床误差提供了测量方法和补偿依据.

  18. Velocity-aligned Doppler spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z.; Koplitz, B.; Wittig, C.

    1989-03-01

    The technique of velocity-aligned Doppler spectrosocopy (VADS) is presented and discussed. For photolysis/probe experiments with pulsed initiation, VADS can yield Doppler profiles for nascent photofragments that allow detailed center-of-mass (c.m.) kinetic energy distributions to be extracted. When compared with traditional forms of Doppler spectroscopy, the improvement in kinetic energy resolution is dramatic. Changes in the measured profiles are a consequence of spatial discrimination (i.e., focused and overlapping photolysis and probe beams) and delayed observation. These factors result in the selective detection of species whose velocities are aligned with the wave vector of the probe radiation k/sub pr/, thus revealing the speed distribution along k/sub pr/ rather than the distribution of nascent velocity components projected upon this direction. Mathematical details of the procedure used to model VADS are given, and experimental illustrations for HI, H/sub 2/S, and NH/sub 3/ photodissociation are presented. In these examples, pulsed photodissociation produces H atoms that are detected by sequential two-photon, two-frequency ionization via Lyman-..cap alpha.. with a pulsed laser (121.6+364.7 nm), and measuring the Lyman-..cap alpha.. Doppler profile as a function of probe delay reveals both internal and c.m. kinetic energy distributions for the photofragments. Strengths and weaknesses of VADS as a tool for investigating photofragmentation phenomena are also discussed.

  19. Photonic band-gap properties for two-component slow light

    CERN Document Server

    Ruseckas, J; Juzeliunas, G; Unanyan, R G; Otterbach, J; Fleischhauer, M

    2011-01-01

    We consider two-component "spinor" slow light in an ensemble of atoms coherently driven by two pairs of counterpropagating control laser fields in a double tripod-type linkage scheme. We derive an equation of motion for the spinor slow light (SSL) representing an effective Dirac equation for a massive particle with the mass determined by the two-photon detuning. By changing the detuning the atomic medium acts as a photonic crystal with a controllable band gap. If the frequency of the incident probe light lies within the band gap, the light tunnels through the sample. For frequencies outside the band gap, the transmission probability oscillates with increasing length of the sample. In both cases the reflection takes place into the complementary mode of the probe field. We investigate the influence of the finite excited state lifetime on the transmission and reflection coefficients of the probe light. We discuss possible experimental implementations of the SSL using alkali atoms such as Rubidium or Sodium.

  20. Pancreatic capillary blood flow during caerulein-induced pancreatitis evaluated by a laser-doppler flowmeter in rats Estudo das alterações do fluxo capilar pancreático após infusão de ceruleína avaliado por laser-Doppler em ratos

    Directory of Open Access Journals (Sweden)

    Roberto Ferreira Meirelles Jr.

    2003-01-01

    Full Text Available PURPOSE: The pancreatic capillary blood flow (PCBF was studied to determine its alterations during caerulein-induced pancreatitis in rats. METHODS: Twenty rats were divided in groups: control and caerulein. A laser-Doppler flowmeter to measure PCBF continuously was used. Blood pressure (BP and heart rate (HR were monitored. Serum biochemistry analyses were determined. Histopathological study was performed. RESULTS: The PCBF measured a mean of 109.08 ± 14.54% and 68.24 ± 10.47% in control group and caerulein group, respectively. Caerulein group had a mean decrease of 31.75 ± 16.79%. The serum amylase was 1323.70 ± 239.10U.I-1 and 2184.60 ± 700.46U.I-1 in control and caerulein groups, respectively. There was a significant difference in the PCBF (pOBJETIVO: O fluxo capilar pancreático (FCP foi estudado para determinar suas alterações durante a pancreatite aguda induzida por ceruleína, em ratos. MÉTODOS: Vinte ratos foram divididos em grupo controle e grupo ceruleína. Um laser-Doppler fluxímetro foi empregado para determinar, continuamente, o FCP durante 120 minutos. A pressão arterial média (PAM e a freqüência cardíaca (FC foram determinadas, durante o experimento. Análise bioquímica sérica e estudo histopatológico, por microscopia ótica, do tecido pancreático foram realizados, ao final do experimento. RESULTADOS: O FCP foi em média 109,08 ± 2,17% e 68,24 ± 16,79% nos grupos controle e ceruleína , respectivamente. No grupo ceruleína, houve uma diminuição média de 31,75 ± 16,79%. Os níveis de amilase sérica foram de 1323,70 ± 239,10U.I-1 e 2184,60 ± 700,46U.I-1 nos grupos controle e ceruleína, respectivamente. Houve diferença significante (p<0,05 no FCP e na amilasemia, quando comparado o grupo controle com o grupo ceruleína. Embora micro e macrovacuolização estivessem presentes no grupo ceruleína, não houve diferença histológica entre os grupos. CONCLUSÃO: A diminuição do FCP parece um evento precoce

  1. Rotational Doppler effect in nonlinear optics

    Science.gov (United States)

    Li, Guixin; Zentgraf, Thomas; Zhang, Shuang

    2016-08-01

    The translational Doppler effect of electromagnetic and sound waves has been successfully applied in measurements of the speed and direction of vehicles, astronomical objects and blood flow in human bodies, and for the Global Positioning System. The Doppler effect plays a key role for some important quantum phenomena such as the broadened emission spectra of atoms and has benefited cooling and trapping of atoms with laser light. Despite numerous successful applications of the translational Doppler effect, it fails to measure the rotation frequency of a spinning object when the probing wave propagates along its rotation axis. This constraint was circumvented by deploying the angular momentum of electromagnetic waves--the so-called rotational Doppler effect. Here, we report on the demonstration of rotational Doppler shift in nonlinear optics. The Doppler frequency shift is determined for the second harmonic generation of a circularly polarized beam passing through a spinning nonlinear optical crystal with three-fold rotational symmetry. We find that the second harmonic generation signal with circular polarization opposite to that of the fundamental beam experiences a Doppler shift of three times the rotation frequency of the optical crystal. This demonstration is of fundamental significance in nonlinear optics, as it provides us with insight into the interaction of light with moving media in the nonlinear optical regime.

  2. Velocity-aligned Doppler spectroscopy

    Science.gov (United States)

    Xu, Z.; Koplitz, B.; Wittig, C.

    1989-03-01

    The use of velocity-aligned Doppler spectroscopy (VADS) to measure center-of-mass kinetic-energy distributions of nascent photofragments produced in pulsed-initiation photolysis/probe experiments is described and demonstrated. In VADS, pulsed photolysis and probe laser beams counterpropagate through the ionization region of a time-of-flight mass spectrometer. The theoretical principles of VADS and the mathematical interpretation of VADS data are explained and illustrated with diagrams; the experimental setup is described; and results for the photodissociation of HI, H2S, and NH3 are presented in graphs and characterized in detail. VADS is shown to give much higher kinetic-energy resolution than conventional Doppler spectroscopy.

  3. Initial data problems for the two-component Camassa-Holm system

    Directory of Open Access Journals (Sweden)

    Xiaohuan Wang

    2014-06-01

    Full Text Available This article concerns the study of some properties of the two-component Camassa-Holm system. By constructing two sequences of solutions of the two-component Camassa-Holm system, we prove that the solution map of the Cauchy problem of the two-component Camassa-Holm system is not uniformly continuous in $H^s(\\mathbb{R}$, $s>5/2$.

  4. Laser Doppler Imaging para quantificação do fluxo sanguíneo de polpa digital em condições basais e após estímulo frio em pacientes com esclerose sistêmica Quantification of basal digital blood flow and after cold stimulus by laser doppler imaging in patients with systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Marcelo José Uchoa Corrêa

    2010-04-01

    Full Text Available OBJETIVO: Determinar o comportamento dinâmico do fluxo sanguíneo da microcirculação digital, antes e após dois estímulos frios (EF de diferentes intensidades, utilizando o método do Laser Doppler Imaging (LDI em pacientes com esclerose sistêmica (ES e controles saudáveis. MÉTODOS: Foram incluídos 14 pacientes com ES (51,2 ± 5,5 anos de idade e 12 controles saudáveis (44,8 ± 9,9 anos. Foram realizados dois protocolos alternativos de EF (submersão das mãos em água a 10 ºC ou 15 ºC, durante 1 minuto. O fluxo médio das quatro polpas digitais da mão esquerda (FPD foi mensurado com a utilização do LDI (Moor LDI-VR, em condições basais, nos períodos de 1, 4, 10, 25 e 40 minutos após EF. RESULTADOS: O fluxo basal foi significativamente menor em ambos os protocolos em pacientes com ES comparados a controles (312,9 ± 102,7 versus 465,4 ± 135,4 PU, P = 0,006, no protocolo a 15 ºC; 305,2 ± 121,0 versus 437,9 ± 119,8 PU, P = 0,01, no protocolo a 10 ºC. Nos controles houve declínio significativo do FPD após EF, em comparação aos valores basais apenas no tempo de um minuto após EF a 15 ºC (P = 0,001 e nos tempos de 1 e 25 minutos após EF a 10 ºC (P = 0,005; P = 0,001, respectivamente. Nos pacientes com ES, houve declínio significativo do FPD nos tempos de 1, 4 e 10 minutos após ambos EFs (P OBJECTIVES: The objective of this study was to investigate the dynamic behavior of the blood flow of the microvascular circulation of the fingertips before and after two cold stimuli (CS, using Laser Doppler Imaging with different intensities in patients with systemic sclerosis (SSc and in healthy individuals. PATIENTS AND METHODS: Fourteen SSc patients (51.2 ± 5.5 years with Raynaud's phenomenon and 12 healthy controls (44.8 ± 9.0 years were included in this study. Two CS protocols (submersion of the hands in water at 10 ºC or 15 ºC for 1 minute were performed on the same day. Mean fingertip blood flow (FBF of four digits of

  5. Analytical method for yrast line states in the interacting two-component Bose-Einstein condensate

    Institute of Scientific and Technical Information of China (English)

    解炳昊; 景辉

    2002-01-01

    The yrast spectrum for the harmonically trapped two-component Bose-Einstein condensate (BEC), omitting thedifference between the two components, has been studied using an analytical method. The energy eigenstates andeigenvalues for L=0,1,2,3 are given. We illustrate that there are different eigenstate behaviours between the even Land odd L cases for the two-component BEC in two dimensions. Except for symmetric states, there are antisymmetricstates for the permutation of the two components, which cannot reduce to those in a single condensate case when thevalue of L is odd.

  6. Characterization and application of a doppler global velocimeter with laser frequency modulation for turbulent flow investigations; Charakterisierung und Anwendung eines Doppler-Global-Velozimeters mit Laserfrequenzmodulation fuer die Untersuchung turbulenter Stroemungen

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Andreas [Technische Univ. Dresden (Germany). Professur fuer Mess- und Prueftechnik

    2011-07-01

    Investigating turbulent flows requires non-intrusive velocity measurement methods with a low measurement uncertainty (< 1%), a high measurement rate (> 10kHz) and field/array measurement capability. For this purpose, the potential of Doppler global velocimetry (DGV) is revealed by estimating the minimum achievable measurement uncertainty due to stochastic errors according the Cramer-Rao inequality. The estimation yields a minimum uncertainty of about 0.03 m/s, which could be achieved by an optimized measurement system. Compared with current DGV systems, the uncertainty was decreased by one order of magnitude. Furthermore, the measurement rate was increased significantly by substituting commonly used CCD devices by faster detector arrays. Finally, non-intrusive measurements of velocity spectra up to about 10 kHz are possible simultaneously at 25 points for the first time with DGV. The technique is applied for vortex measurements in the wake of a cylinder and in the tip gap flow of an axial compressor model. This illustrates promising applications in turbo machine flows for increasing their efficiency and performance. (orig.)

  7. Spectroscopic observation of the rotational Doppler effect.

    Science.gov (United States)

    Barreiro, S; Tabosa, J W R; Failache, H; Lezama, A

    2006-09-15

    We report on the first spectroscopic observation of the rotational Doppler shift associated with light beams carrying orbital angular momentum. The effect is evidenced as the broadening of a Hanle electromagnetically induced transparency coherence resonance on Rb vapor when the two incident Laguerre-Gaussian laser beams have opposite topological charges. The observations closely agree with theoretical predictions.

  8. Two-Component Super AKNS Equations and Their Finite-Dimensional Integrable Super Hamiltonian System

    OpenAIRE

    Jing Yu; Jingwei Han

    2014-01-01

    Starting from a matrix Lie superalgebra, two-component super AKNS system is constructed. By making use of monononlinearization technique of Lax pairs, we find that the obtained two-component super AKNS system is a finite-dimensional integrable super Hamiltonian system. And its Lax representation and $r$ -matrix are also given in this paper.

  9. TASI 2011 lectures notes: two-component fermion notation and supersymmetry

    OpenAIRE

    Martin, Stephen P.

    2012-01-01

    These notes, based on work with Herbi Dreiner and Howie Haber, discuss how to do practical calculations of cross sections and decay rates using two-component fermion notation, as appropriate for supersymmetry and other beyond-the-Standard-Model theories. Included are a list of two-component fermion Feynman rules for the Minimal Supersymmetric Standard Model, and some example calculations.

  10. Relativistic two-component jet evolutions in 2D and 3D

    NARCIS (Netherlands)

    Meliani, Z.; Keppens, R.

    2009-01-01

    Observations of astrophysical jets and theoretical arguments suggest a transverse stratification with two components induced by intrinsic features of the central engine (accretion disk + black hole). We study two-component jet dynamics for an inner fast low density jet, surrounded by a slower, dense

  11. Two-Component Super AKNS Equations and Their Finite-Dimensional Integrable Super Hamiltonian System

    Directory of Open Access Journals (Sweden)

    Jing Yu

    2014-01-01

    Full Text Available Starting from a matrix Lie superalgebra, two-component super AKNS system is constructed. By making use of monononlinearization technique of Lax pairs, we find that the obtained two-component super AKNS system is a finite-dimensional integrable super Hamiltonian system. And its Lax representation and r-matrix are also given in this paper.

  12. Preparation and frictional investigation of the two-components silanes deposited on alumina surface

    Energy Technology Data Exchange (ETDEWEB)

    Kośla, K.; Grobelny, J.; Cichomski, M., E-mail: mcichom@uni.lodz.pl

    2014-09-30

    Highlights: • The two-component silane films on the alumina surface were obtained by a combination of soft lithography and vapor phase deposition method. • The effectiveness of modification procedure was monitored by AFM topography images. • By using gas phase deposition method succeeded in obtaining a good reproduction of pattern. • Silane films with low surface free energy and coefficient of friction values were obtained. • The frictional performance in milli-Newton load range of one- and two-component films was investigated by microtribometry. - Abstract: Functionalization and pattering technique that permits two-component pattern-specific modification of alumina surface with silanes molecules are reported. The method relies on a two-component molecular system that simultaneously decreases coefficient of friction of the alumina surface and provides uniform chemical functionality suitable for further elaboration. Pattern/two-component modification is achieved via gas-phase deposition of the silanes using polydimethylsiloxane stamp. The frictional behaviors of the two-component films of the silane molecules with different chain length covalently absorbed on alumina surfaces, were characterized by the ball-disk (microtribometer) tester. The surfaces of the substrate modified by two-component molecular films were examined by atomic force microscopy (AFM). The measured tribological results showed that the mixing of the fluoroalkylsilane and alkylsilane enhance the lubrication and decrease the friction compared to the one-component thin films.

  13. Sub-Doppler resolution mid-infrared spectroscopy using a difference-frequency-generation source spectrally narrowed by laser linewidth transfer.

    Science.gov (United States)

    Sera, Hideyuki; Abe, Masashi; Iwakuni, Kana; Okubo, Sho; Inaba, Hajime; Hong, Feng-Lei; Sasada, Hiroyuki

    2015-12-01

    The spectral linewidth of a 3.28 μm difference-frequency-generation source has been reduced to 3.5 kHz using a laser linewidth transfer technique [Opt. Express21, 7891 (2013)]. We use an optical frequency comb with a broad servo bandwidth to transfer a narrow linewidth of a pump laser, a 1.06 μm Nd:YAG laser, to a signal laser, a 1.57 μm external-cavity laser diode. This source enables us to record the Lamb dip of the ν3 band R(2) E transition of methane with a molecular spectral linewidth of 21 kHz while the frequency axis is absolutely calibrated.

  14. Methods of producing epoxides from alkenes using a two-component catalyst system

    Science.gov (United States)

    Kung, Mayfair C.; Kung, Harold H.; Jiang, Jian

    2013-07-09

    Methods for the epoxidation of alkenes are provided. The methods include the steps of exposing the alkene to a two-component catalyst system in an aqueous solution in the presence of carbon monoxide and molecular oxygen under conditions in which the alkene is epoxidized. The two-component catalyst system comprises a first catalyst that generates peroxides or peroxy intermediates during oxidation of CO with molecular oxygen and a second catalyst that catalyzes the epoxidation of the alkene using the peroxides or peroxy intermediates. A catalyst system composed of particles of suspended gold and titanium silicalite is one example of a suitable two-component catalyst system.

  15. Two-component generalizations of the periodic Camassa-Holm and Degasperis-Procesi equations

    CERN Document Server

    Escher, Joachim; Lenells, Jonatan

    2010-01-01

    We use geometric methods to study two natural two-component generalizations of the periodic Camassa-Holm and Degasperis-Procesi equations. We show that these generalizations can be regarded as geodesic equations on the semidirect product of the diffeomorphism group of the circle $\\Diff(S^1)$ with some space of sufficiently smooth functions on the circle. Our goals are to understand the geometric properties of these two-component systems and to prove local well-posedness in various function spaces. Furthermore, we perform some explicit curvature calculations for the two-component Camassa-Holm equation, giving explicit examples of large subspaces of positive curvature.

  16. Evolution and phyletic distribution of two-component signal transduction systems.

    Science.gov (United States)

    Wuichet, Kristin; Cantwell, Brian J; Zhulin, Igor B

    2010-04-01

    Two-component signal transduction systems are abundant in prokaryotes. They enable cells to adjust multiple cellular functions in response to changing environmental conditions. These systems are also found, although in much smaller numbers, in lower eukaryotes and plants, where they appear to control a few very specific functions. Two-component systems have evolved in Bacteria from much simpler one-component systems bringing about the benefit of extracellular versus intracellular sensing. We review reports establishing the origins of two-component systems and documenting their occurrence in major lineages of Life. Copyright 2010 Elsevier Ltd. All rights reserved.

  17. Travelling wave solutions for some two-component shallow water models

    Science.gov (United States)

    Dutykh, Denys; Ionescu-Kruse, Delia

    2016-07-01

    In the present study we perform a unified analysis of travelling wave solutions to three different two-component systems which appear in shallow water theory. Namely, we analyze the celebrated Green-Naghdi equations, the integrable two-component Camassa-Holm equations and a new two-component system of Green-Naghdi type. In particular, we are interested in solitary and cnoidal-type solutions, as two most important classes of travelling waves that we encounter in applications. We provide a complete phase-plane analysis of all possible travelling wave solutions which may arise in these models. In particular, we show the existence of new type of solutions.

  18. Two-Component Wadati-Konno-Ichikawa Equation and Its Symmetry Reductions

    Institute of Scientific and Technical Information of China (English)

    QU Chang-Zheng; YAO Ruo-Xia; LI Zhi-Bin

    2004-01-01

    @@ It is shown that two-component Wadati-Konno-Ichikawa (WKI) equation, i.e. a generalization of the well-known WKI equation, is obtained from the motion of space curves in Euclidean geometry, and it is exactly a system for the graph of the curves when the curve motion is governed by the two-component modified Korteweg-de Vries flow. Group-invariant solutions of the two-component WKI equation which corresponds to an optimal system of its Lie point symmetry groups are obtained, and its similarity reductions to systems of ordinary differential equations are also given.

  19. Scale and Contour: Two Components of a Theory of Memory for Melodies.

    Science.gov (United States)

    Dowling, W. Jay

    1978-01-01

    The author concentrates on two components of memory which contribute to the reproduction and recognition of melodies, namely, melodic contour and musical scale. A new experiment is reported that shows the interdependence of both components. (Author/RK)

  20. Role of functionality in two-component signal transduction: A stochastic study

    Science.gov (United States)

    Maity, Alok Kumar; Bandyopadhyay, Arnab; Chaudhury, Pinaki; Banik, Suman K.

    2014-03-01

    We present a stochastic formalism for signal transduction processes in a bacterial two-component system. Using elementary mass action kinetics, the proposed model takes care of signal transduction in terms of a phosphotransfer mechanism between the cognate partners of a two-component system, viz., the sensor kinase and the response regulator. Based on the difference in functionality of the sensor kinase, the noisy phosphotransfer mechanism has been studied for monofunctional and bifunctional two-component systems using the formalism of the linear noise approximation. Steady-state analysis of both models quantifies different physically realizable quantities, e.g., the variance, the Fano factor (variance/mean), and mutual information. The resultant data reveal that both systems reliably transfer information of extracellular environment under low external stimulus and in a high-kinase-and-phosphatase regime. We extend our analysis further by studying the role of the two-component system in downstream gene regulation.