WorldWideScience

Sample records for twelfth aec air

  1. Index to the AEC/ERDA/DOE Air Cleaning Conferences

    International Nuclear Information System (INIS)

    Burchsted, C.A.

    1980-01-01

    A comprehensive index to the papers in the second through sixteenth AEC/ERDA/DOE Nuclear Air Cleaning Conference is discussed. The index will be published in early 1981 and will be designated as Volume 3 of the proceeding of the sixteenth conference. The index has three parts, a straight numeric tabulation, an author index, and a key word in context (KWIC) index

  2. Index to the 1st through 16th AEC/ERDA/DOE nuclear air cleaning conferences

    International Nuclear Information System (INIS)

    Burchsted, C.A.

    1981-02-01

    The Proceedings of the sixteen conferences comprise a vertible encyclopedia on the technology of nuclear air and gas treatment and the control of airborne nuclear waste. These Proceedings cover the history of the technology; describe most of the research and developments in the field, worldwide, since the early 1950's; describe the problems that have been encountered and the solutions found to those problems; and summarize experience with equipment and systems developed for the control of airborne radioactive wastes in laboratory, radiochemical, and reactor operations, both government and commercial. The problem with this encyclopedia is that there has been no index to it; there has been no easy way for searching it to find what was available. This index fills the gap. The first conference was an informal meeting of a number of interested parties from among the then AEC contractors. Consequently, there were no proceedings for that meeting. The subsequent conferences, with their years, locations, and Proceedings numbers, are listed. This index consists of three parts: a tabulation of papers and their authors by paper number (Part I); a tabulation of papers and their paper numbers by author (Part II); and a key-word-in context (KWIC) index of papers. The paper number is a two-part designation consisting of the number of the conference (2, 3...16) followed by the page number of the paper in the corresponding Proceedings. The author index lists each author who has participated in the air cleaning conferences over the years, and the paper index lists all authors of the respective papers. The KWIC index is, in effect, a comprehensive subject cross index; each paper is listed as many times, by keyword, as there are major terms (i.e., keywords) in its title. Although this multiple listing results in a lengthy list, it provides a very deep cross-indexing of the papers

  3. AEC Regulatory view of the reliability of air cleaning systems in nuclear facilities

    International Nuclear Information System (INIS)

    Bellamy, R.R.; Zavadoski, R.W.

    1975-01-01

    Air cleaning systems in nuclear facilities can be divided into three categories: ventilation exhaust systems, containment atmosphere cleanup systems, and process offgas systems. These systems have been the subject of numerous reports, regulatory guides, discussions, and meetings. Some of the analyses have been critical of the operation and design of these air cleaning systems--in particular, the engineered safety features containment atmosphere cleanup systems. Although for the most part the criticism is applicable, and recognizing that there are a number of unresolved issues pertaining to gaseous waste management systems, there are data to show that air cleaning systems in use in nuclear facilities are performing their intended function. (U.S.)

  4. Twelfth Semiannual Report of the Commission to the Congress. Major Activities in the Atomic Energy Programs, January - June 1952

    Energy Technology Data Exchange (ETDEWEB)

    Dean, Gordon

    1952-07-01

    The document represents the twelfth semiannual Atomic Energy Commission (AEC) report to Congress. The report sums up the major activities and developments in the national atomic energy program covering the period January - June 1952.

  5. The AEC and developing countries

    International Nuclear Information System (INIS)

    Ouvrieu, J.B.

    1983-01-01

    A historical background shows how AEC's activities have changed and consequently, the development of the AEC's relations with developing countries. Some examples serve to illustrate the different types of AEC cooperation with developing countries [fr

  6. Study of Concentrations of Available Cations and Anions in PM2.5 in the Air of Twelfth Region of Tehran City

    Directory of Open Access Journals (Sweden)

    Hossean Arfaeinia

    2017-04-01

    Full Text Available Background: In the last few decades, the city's air quality has become a major concern; especially there is strong evidence about health effects of particulate matter in urban communities.In addition to suspended particles concentration, the ionic part of suspended particles is also very important, So that some studies  ions like Sulfate is the reson of increasing the respiratory diseases.So the aim of this study was to study of concentration of PM2.5 particles and their ionic componentsincluding major anions and cations in twelfth region of Tehran city in 2013. Materials & Methods: This cross - sectional study was conducted in the air of twelfth region of Tehran. PM2.5 concentration was calculated with sampling by frmOMNITMAmbient Air Sampler with PTFE filter with a diameter of 47 mm and through the weight measurement.Concentration of anions and cations which had associated with PM2.5 particles was read after collected sample preparation and injection to device Ion Chromatography (IC Metrohm 850 model. Correlation matrix was calculated between anions and cations. Data analysis was carried out by Excel and SPSS version 18 and One-Way ANOVA test. Results: The mean daily concentration of PM2.5 particles was 19.41 µg/m3 during the study. One-Way ANOVA test showed a significant difference at the 0.05 level between PM2.5 concentrations on different days of the week. Concentrations for sodium, potassium, ammonium, calcium, magnesium, sulfate, nitrate, chloride were obtained 0.28, 0.06, 0.49, 0.87, 0.63, 56.3, 1.43 and 0.71 µg/m3, respectively, and no value was detected for fluoride and nitrite. Balance between anions and cations were calculated and the correlation coefficient (R2 were obtained 0.972 between the anions and cations. Conclusion The mean concentrations of PM2.5 was higher than the air standards in Iran and WHO guidelines (25 µg/m3 and EPA standards (35 µg/m3. In a study reported that the One-Way ANOVA test between particle

  7. Long-term mortality benefits of air quality improvement during the twelfth five-year-plan period in 31 provincial capital cities of China

    Science.gov (United States)

    Liu, Tao; Cai, Yuanyuan; Feng, Baixiang; Cao, Ganxiang; Lin, Hualiang; Xiao, Jianpeng; Li, Xing; Liu, Sha; Pei, Lei; Fu, Li; Yang, Xinyi; Zhang, Bo; Ma, Wenjun

    2018-01-01

    The severe air pollution across China in the past several years has made the Chinese government recognize its significant impacts on public health and society, and take enormous efforts to improve the air quality all over the country, especially during the Twelfth Five-Year Plan (12th FYP). However, the overall effectiveness of these air pollution control policies remains unclear. In this study, we selected the 31 municipalities and provincial capital cities in mainland China as study settings. We collected the annual average population size, mortality rates (total mortality and mortality due to cardiovascular diseases, respiratory diseases, total cancer, lung cancer and breast cancer) and concentrations of air pollutants (PM10, PM2.5, SO2 and NO2) in each capital city from 2010 to 2015 from national or local Statistical Yearbooks. The effect sizes of air pollutants on mortality were obtained from previously published meta analyses or cohort studies. We first estimated the annual mortality rates attributed to the changes in air pollutant concentrations for every city in each year. Then, we further estimated the mortality benefits in the scenarios where the air quality had reached the grade II levels of Chinese Ambient Air Quality Standards (CAAQS) and World Health Organization (WHO) guidelines. In most capital cities, we observed dominant decreases in air pollutant concentrations during the 12th FYP, particularly from 2013 to 2015, which has led to significant mortality benefits for the public. A total of 121,658 deaths (0.441‰) have been prevented due to the decrease of PM2.5concentrations from 2013 to 2015 in all included cities. The morality benefits were larger in capital cities located in the key regions (the three main regions and ten city groups) than the other cities. In addition, more mortality benefits could be obtained in the future if the air quality reaches the grade II levels of Chinese Ambient Air Quality Standards (CAAQS) or WHO guidelines. We

  8. "Twelfth Night" for Kids.

    Science.gov (United States)

    Burdett, Lois; Coburn, Christine

    Aimed at primary-age children, this book brings William Shakespeare's "Twelfth Night" to them, recognizing that children, properly guided, will take to Shakespeare's characters and stories like "ducks to water"; in the process they find their inner voices, they collaborate, they improvise, and they communicate. Illustrated with…

  9. The Twelfth US Air Force. Tactical and Operational Innovations in the Mediterranean Theater of Operations, 1943-1944

    Science.gov (United States)

    2007-02-01

    Unicorn , Battler, At- tacker, Hunter, and Stalker were used to augment the aircraft operating from Sicilian airfields and conducted 713 sorties...success.103 The Fifth Army G­2 estimated that heavy German personnel casualties, dam­ aged equipment, and loss of supplies resulted in a significant...prevent enemy air penetration of the assault beaches and convoys, defensive air patrols were used to provide three different layers of cover- age . The

  10. AEC review 1988

    International Nuclear Information System (INIS)

    1988-10-01

    Activities of the Atomic Energy Corporation of South Africa Limited (AEC) are reviewed. The activities of each of the six Management Units, namely Uranium Processing, Uranium Enrichment, Research and Development, Engineering, Human Resources and Finance and Commercial Affairs, are discussed. The Uranium Processing Unit includes the two major production programmes, viz. UF6 production and fuel-element fabrication. The objective of the Uranium Enrichment Management Unit is the supply of enriched uranium. The unit operates two uranium enrichment plants, the semicommercial Z Plant and the pilot plant. The Research and Developement Unit is structured into 7 programmes which are related mainly to the fuel cycle. It concentrates on facets of the nuclear fuel cycle, by-products of the nuclear industry and research services, as well as transfer of specialized technology to private industry. The Engineering Unit includes Engineering Services, Technical Services, Nuclear Waste Technology which involves the handling and disposal of all radioactive waste in South Africa, Central Quality Services, and Safety. The Human Resources Management Unit is divided in four functional units, viz. Manpower Services, Labour Relations, Training and Development and Manpower Specialized Services. The Unit Finance and Commercial Affairs consists of Financial and Accounting Services, Management Services, Corporate Information and Marketing and Commercial Services. A list of products and services delivered by the AEC is included as well as a list of publications by staff members

  11. Immunoregulation by airway epithelial cells (AECs against respiratory virus infection

    Directory of Open Access Journals (Sweden)

    Yan YAN

    2017-11-01

    Full Text Available The respiratory tract is primary contact site of the body and environment, and it is ventilated by 10-20 thousand liters of air per day. Inevitably, the respiratory system comes into contact with airborne microbes, which contain the disease-causing pathogens. Airway epithelial cells (AECs are known to have innate sensor functions, which are similar to the "professional" immune cells, such as alveolar macrophage and sub- or intra-epithelial dendritic cells (DCs. Thus AECs are able to detect invading microbial danger including different types of respiratory viruses, and mount a potent host response, for example, activating type Ⅰ interferon signaling pathway genes. To avoid chronic inflammation and maintain the immunological homeostasis, the pulmonary system has developed intrinsic mechanisms to control local immune responses. Most recently, the role of AECs in control of local immunity has gained much attention, as 1 AECs express the pattern recognition receptors (PRRs, such as Toll-like receptors, retinoic acid inducible gene Ⅰ (RIG-I-like receptor, and so on, thus AECs are equipped to participate in innate detection of microbial encounter; 2 To keep immunological homeostasis in the respiratory tract, AECs behave not only as innate immune sensors but also as immune modulators in parallel, through modulating the sensitivity of innate immune sensing of both AECs per se and sub- or intra-epithelial immune cells; 3 Loss of modularity capacity of AECs might be involved in the development of chronic airway diseases. In present review, how the AECs act will be intensively discussed in response to respiratory viruses and modulate the local immunity through cis- and trans-factors (direct and indirect factors, as well as the consequence of impairment of this control of local immunity, in the development and exacerbation of airway diseases, such as acute and chronic rhinosinusitis. DOI: 10.11855/j.issn.0577-7402.2017.10.02

  12. AEC determines uranium enrichment policy

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The Advisory Committee on Uranium Enrichment of the Atomic Energy Commission (AEC) has submitted a report to AEC chairman concerning the promotion of the introduction of advanced material, high performance centrifuges to replace conventional metallic drum centrifuges, and the development of next generation advanced centrifuges. The report also called for the postponement until around 1997 of the decision whether the development should be continued or not on atomic vapor laser isotope separation (AVLIS) and molecular laser isotope separation (MLIS) processes, as well as the virtual freezing of the construction of a chemical process demonstration plant. The report was approved by the AEC chairman in August. The uranium enrichment service market in the world will continue to be characterized by oversupply. The domestic situation of uranium enrichment supply-demand trend, progress of the expansion of Rokkasho enrichment plant, the trend in the development of gas centrifuge process and the basic philosophy of commercializing domestic uranium enrichment are reported. (K.I.)

  13. AEC to Referee, Not Promote, Industry.

    Science.gov (United States)

    1971-10-29

    A major turnabout in the attitude of the Atomic Energy Commission toward the nuclear power industry was signaled last week by the ntew AEC chairman James R. Schlesinger. With patrician froideur, Schlesinger informed a mass gathering of the nuclear power industry at Bal Harbour, Florida, that from henceforth the AEC woLuld act as the referee of nuclear power, not its promoter. Saying he would dispense with the "anecdotes and clumsy jests" customary on such occasions, Schlesinger served notice on the nuclear banqueters that their cozy relationship with the AEC was at an end. The industry should not expect the AEC to fight its battles: it should take its own case to the public-as the Sierra Club does. Nor did the AEC intend to bend the rules in industry's favor. "We have had a fair amount of advice on how to evade the clear mandate of the federal courts. It is advice we did not think proper to accept," Schlesinger said. Even on matters of engineering quality, the diners were told they knew full well they had "reason to blush." Roused out of any postprandial euphoria by this glacial disdain, the industry representatives heard the new chairman announce the following radical upheavals in official AEC philosophy.

  14. The Twelfth General Elections in Malaysia

    Directory of Open Access Journals (Sweden)

    Tunku Mohar Mokhtar

    2008-06-01

    Full Text Available Abstract: The twelfth general elections in Malaysia resulted in the ruling coalition (Barisan Nasional, BN losing its two-thirds majority in Parliament. Denying the BN its sought after two-thirds majority is what the opposition parties were campaigning for. Additionally, they won five state assemblies. The electorate voted on the basis of “bread and butter” issues which were highlighted by the ruling coalition as well as the opposition parties.

  15. The Twelfth General Elections in Malaysia

    OpenAIRE

    Tunku Mohar Mokhtar

    2008-01-01

    Abstract: The twelfth general elections in Malaysia resulted in the ruling coalition (Barisan Nasional, BN) losing its two-thirds majority in Parliament. Denying the BN its sought after two-thirds majority is what the opposition parties were campaigning for. Additionally, they won five state assemblies. The electorate voted on the basis of “bread and butter” issues which were highlighted by the ruling coalition as well as the opposition parties.

  16. [Acute palsy of twelfth cranial nerve].

    Science.gov (United States)

    Munoz del Castillo, F; Molina Nieto, T; De la Riva Aguilar, A; Triviño Tarradas, F; Bravo-Rodríguez, F; Ramos Jurado, A

    2005-01-01

    The hypoglossal nerve or Twelfth-nerve palsy is a rare damage with different causes: tumors or metastases in skull base, cervicals tumors, schwannoma, dissection or aneurysm carotid arteries, stroke, trauma, idiopathic cause, radiation, infections (mononucleosis) or multiple cranial neuropathy. Tumors were responsible for nearly half of the cases in different studies. We studied a female with hypoglossal nerve acute palsy. We made a differential diagnostic with others causes and a review of the literature.

  17. AEC testing in a CR environment

    International Nuclear Information System (INIS)

    McLeod, R.

    2004-01-01

    Full text: Testing of x-ray machine automatic exposure control (AEC) functionality for varying kVp and patient thickness is a fundamental health physics check. Current test protocols tend to be based on testing in a film environment using film optical density as the measure of conformance. With the move into the digital x-ray image age with the use of computed radiography (CR) and digital radiography (DR) equipment and its associated image storage and retrieval system (PACS) a new AEC testing protocol is required. All CR systems provide a dose assessment tool (called Exposure Index or EI by Kodak) that could be used as a surrogate for optical density. However this work aims to derive an efficient means of assessing the functioning of the AEC of x-ray machines in a CR environment using dose measurement alone. This would eliminate the need to process the many image plates normally required for AEC testing in order to obtain and analyse the exposure measure from the CR system. The EI, and other brand's equivalents, is calibrated for a given condition (for Kodak 80kVp 0.5mmCu + 1mmAl). In order to use dose measurement alone the relationship between EI and dose must be known for varying kVp and patient thicknesses (represented by a perspex phantom). This will depend on the response of the CR plate to varying beam energies. This was assessed using a series of paired exposures at various kVp and perspex thicknesses. In the first exposure of each pair a Kodak CR plate was used, processed in the normal way, and the EI noted. In a second identical exposure an Innovision 35050A pancake ionization chamber was placed in the bucky tray within a specially modified film cassette and the dose measured. Over the 50-125kVp range of clinical use the kV response of the Kodak PSP's shown below is essentially flat for a set dose to the image plate and filtered using the standard Kodak method of 0.5mmCu + 1mmAl. Similar data will be presented showing this relationship using a perspex

  18. AEC Advisory Committee report emphasizes personnel exchanges

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    The Advisory Committee on Cooperation with Developing Countries set up in August 1983 in the AEC has studied for about one year the actual situations of nuclear energy development and utilization in developing countries and their expections toward Japan and also problems in Japan in this connection. The Advisory Committee's report is summarized: significance of nuclear energy cooperation; status of nuclear energy energy utilizations in developing countries; status and problems in Japan's cooperation (technical cooperation through IAEA and technical cooperation by JAERI, JAIF, etc.); future prospects (areas of cooperation including the uses of radioisotopes and radiation and research reactors, nuclear power generation, etc. and tasks of the Government and the private sector in expanding the cooperation). (Mori, K.)

  19. Twelfth workshop on geothermal reservoir engineering: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Ramey, H.J. Jr.; Kruger, P.; Miller, F.G.; Horne, R.N.; Brigham, W.E.; Rivera, J. (Stanford Geothermal Program)

    1987-01-22

    Preface The Twelfth Workshop on Geothermal Reservoir Engineering was held at Stanford University on January 20-22, 1987. The year ending December 1986 was very difficult for the domestic geothermal industry. Low oil prices caused a sharp drop in geothermal steam prices. We expected to see some effect upon attendance at the Twelfth Workshop. To our surprise, the attendance was up by thirteen from previous years, with one hundred and fifty-seven registered participants. Eight foreign countries were represented: England, France, Iceland, Italy, Japan, Mexico, New Zealand, and Turkey. Despite a worldwide surplus of oil, international geothermal interest and development is growing at a remarkable pace. There were forty-one technical presentations at the Workshop. All of these are published as papers in this Proceedings volume. Seven technical papers not presented at the Workshop are also published; they concern geothermal developments and research in Iceland, Italy, and New Zealand. In addition to these forty-eight technical presentations or papers, the introductory address was given by Henry J. Ramey, Jr. from the Stanford Geothermal Program. The Workshop Banquet speaker was John R. Berg from the Department of Energy. We thank him for sharing with the Workshop participants his thoughts on the expectations of this agency in the role of alternative energy resources, specifically geothermal, within the country???s energy framework. His talk is represented as a paper in the back of this volume. The chairmen of the technical sessions made an important contribution to the workshop. Other than Stanford faculty members they included: M. Gulati, K. Goyal, G.S. Bodvarsson, A.S. Batchelor, H. Dykstra, M.J. Reed, A. Truesdell, J.S. Gudmundsson, and J.R. Counsil. The Workshop was organized by the Stanford Geothermal Program faculty, staff, and students. We would like to thank Jean Cook, Marilyn King, Amy Osugi, Terri Ramey, and Rosalee Benelli for their valued help with the meeting

  20. Nuclear criticality safety. Chapter 0530 of AEC manual

    International Nuclear Information System (INIS)

    2006-01-01

    The programme objectives of this chapter of the U.S. Atomic Energy Commission manual on nuclear criticality safety are to protect the health and safety of the public and of the government and contractor personnel working in plants that handle fissionable material and to protect public and private property from the consequences of a criticality accident occurring in AEC-owned plants and other AEC-contracted activities involving fissionable materials

  1. STRENGTHENING COUNSELORS SPIRITUALITY IN FACING ASEAN ECONOMIC COMMUNITY (AEC

    Directory of Open Access Journals (Sweden)

    Muhamad Rozikan

    2017-05-01

    Full Text Available There is an anxiety to face ASEAN Economic Community (AEC. This is natural reaction when we see our readiness to face competition compared with other ASEAN countries. Such manner already exists since the inception of ASEAN in 1967. The anxiety would be a reasonable thing to the enactment of MEA, considering not all the people know what the MEA is. The survey results indicate that the stakeholder both the central government, local government, academia, and society in this country is still relatively have low understanding and knowledge about the ASEAN Economic community (AEC. It is ironic, other ASEAN countries has been intensely preparing steps needed to face AEC, while the majority of the Indonesian people do not know what it is. Modern life along with science, technology and economic progress experienced by Western nations turned out to have caused various situations of life that does not give happiness and a growing sense of inner emptiness. The counselor existence in the counseling today, should be able to develop its human resources, so it is able to answer the problem to encounter global competition of ASEAN Economic Community (AEC. Spiritual counseling and guidance counselors as an alternative solution to deal with the AEC which fully loaded with interest and ability/professionalism in various occupations faced.

  2. Exploring the Client–AEC Interface in Building Lifecycle Integration

    Directory of Open Access Journals (Sweden)

    John M. Kamara

    2013-07-01

    Full Text Available The creation and management of buildings over their lifecycle involves the cooperation of many organizations, which broadly fall into a client domain and AEC (architecture, engineering, construction domain. While this mix of expertise is essential, the ineffective management of the boundaries between these organizations can undermine building lifecycle performance. This paper explores client–AEC interactions at the project development and handover stages, with a view to discovering insights into client–AEC interface management for effective building lifecycle integration (BLI. The concept of boundary objects provided the theoretical framework to discuss findings from two case studies on the project development phase of a private finance initiative project, and the asset development process in a repeat client organization. The findings suggest that there are different emphases in boundary crossing activities at different stages, with boundary roles that relate to decision-making and authority to commit resources being more relevant at the project development stage, whereas the need to explain meanings appear to be more relevant at the handover stage. AEC professionals in client organizations play a crucial role in bridging knowledge boundaries about buildings, but this professional/functional strand to BLI needs to be effectively managed alongside the organizational boundaries, since the authority to resource BLI efforts resides within organizations.

  3. Formerly utilized MED/AEC sites remedial action program. Radiological survey of the Harshaw Chemical Company, Cleveland, Ohio

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Justus, A.L.; Flynn, K.F.

    1984-04-01

    During the MED/AEC era, the Harshaw Chemical Company processed large quantities of normal uranium to produce both oxide and fluoride compounds. This work was done under contract to MED and its successor, AEC. Records indicated that at the time the AEC contract was terminated, the facility was decontaminated by Harshaw and released from AEC control in 1960. However, a search of AEC records indicated that documentation was insufficient to determine whether the decontamination work was adequate by current guidelines. Hence, a radiological assessment of the site ws initiated in 1976. The entire grounds and all buildings were surveyed using surface survey instruments to detect surface contamination and radiation detectors to determine general radiation levels. Extensive surface contamination was found throughout the site. While the major contamination was found in Plant C, significant levels of contamination also were found in 16 other buildings and at 32 exterior locations. The contaminating material seemed to be normal uranium exclusively. Air samples were taken at numerous indoor locations throughout the site, but no elevated levels of radon were detected. This was as expected since normal uranium has been separated from radium and hence radon levels are very low. Several soil samples were taken from around the site. Analyses of these samples indicated extensive soil contamination, as well as suspected contamination of the river bed in the vicinity of the plant outfall. Scheduled subsurface investigation of the site, as well as of the river bed and sewer system, have not been conducted. Levels of contamination at this site are significantly above guidelines for release of the site for unrestricted use. 57 figures, 7 tables

  4. Private Islamic Higher Education in Asean Economic Community (AEC Era

    Directory of Open Access Journals (Sweden)

    Mulyawan Safwandy Nugraha

    2016-12-01

    Full Text Available This article explores the challenge faced by Indonesia in ASEAN Economic Community (AEC era. It is also revealed the Private Islamic Religion Institution (PTKIS strategic to play its role and function in generating human resource. The method used is qualitative in the form of literature study. The result shows that PTKIS are required to adapt and see the AEC as an opportunity to change. A private status should be used as an institutional capital to create and innovate freely, by maximally utilizing the available resources. The management of a reputable institution is seen to be a significant factor for reinforcement. Aspects of visionary leadership, qualified lecturers, a curriculum that is responsive to a change, and an adequate infrastructure become a strengthening point toward the management accountability of universities in creating graduates who are competitive, skillful and qualified.

  5. The Adaptive Ecosystem Climatology (AEC): Design and Development

    Science.gov (United States)

    deRada, S.; Penta, B.; McCarthy, S.; Gould, R. W., Jr.

    2016-02-01

    The concept of ecosystem-based management (EBM), recently introduced to rectify the shortcomings of single-species management policies, has been widely accepted as a basis for the conservation and management of natural resources. In line with NOAA's Integrated Ecosystem Assessment (IEA) Program, EBM is an integrated approach that considers the entire ecosystem and the interactions among species rather than focusing on individual components. This integrative approach relies on heterogeneous data, physical as well as biogeochemical data, among many others. Relative to physical data, however, marine biogeochemical records, also critical in IEA and EBM, are still lacking, both in terms of mature models and in terms of observational data availability. TheAdaptive Ecosystem Climatology (AEC) was conceived as a novel approach to address these limitations, mitigating the shortcomings of the individual components and combining their strengths to enhance decision-making activities. AEC is designed on the concept that a high-frequency climatology can be used as a baseline into which available observational data can be ingested to produce a higher accuracy product. In the absence of observations, the climatology acts as a best estimate. AEC was developed using a long-term simulation of a coupled biophysical numerical model configured for the Gulf of Mexico. Using the model results, we constructed a three-dimensional, dynamically balanced, gridded, static climatology for each calendar day. Using this `static' climatology as a background `first guess', observations from a particular date are ingested via optimal interpolation to `nudge' the climatology toward current conditions, thus providing representative fields for that date (adaptive climatology). With this adaptive approach, AEC can support a variety of EBM objectives, from fisheries, to resource management, to coastal resilience.

  6. Composition of rock core from hole AEC-8, New Mexico

    International Nuclear Information System (INIS)

    Rhoderick, J.E.; Buck, A.D.

    1981-12-01

    AEC-8 is a borehole about 5000 ft deep located within the Waste Isolation Pilot Plant (WIPP) site in southeastern New Mexico. About 28 ft of rock core from seven depth intervals in this hole was characterized by petrographic examination. This included logging, examination of the rock with a stereomicroscope, examination of thin sections with a polarizing microscope, and examination of each sample by x-ray diffraction

  7. Twelfth night of 1917 and the Moscow art theatre Twelfth night of 1917 and the Moscow art theatre

    Directory of Open Access Journals (Sweden)

    Arkady Ostrovsky

    2008-04-01

    Full Text Available On 15 September, 1917, in a letter to Nemirovich-Danchenko, Stanislavsky renounced the stage of the Moscow Art Theatre: I cannot think about any other roles, because I will never be able to do anything, at least in the Moscow Art Theatre. Maybe in some other area or some other place I will be able to rise. Of course I do not mean in other theatres, but in the studios. Othello — free!...1 After the tragedy Stanislavsky had endured with Selo Stepanchikovo, he threw himself into Studio work. He started rehearsing Twelfth Night, a play he had put on at the Society of Art and Literature in 1897. The Studio production of Twelfth Night was played on 25 December 1917, two months to the day after the Revolution. A few months later, Nikolai Efros published a book about the First Studio. It was dedicated to The Cricket on the Hearth but the words Efros used to describe the atmosphere in which Dickens’s production had opened were equally suitable for Twelfth Night: ‘You remember what sort of days those were? On 15 September, 1917, in a letter to Nemirovich-Danchenko, Stanislavsky renounced the stage of the Moscow Art Theatre: I cannot think about any other roles, because I will never be able to do anything, at least in the Moscow Art Theatre. Maybe in some other area or some other place I will be able to rise. Of course I do not mean in other theatres, but in the studios. Othello — free!...1 After the tragedy Stanislavsky had endured with Selo Stepanchikovo, he threw himself into Studio work. He started rehearsing Twelfth Night, a play he had put on at the Society of Art and Literature in 1897. The Studio production of Twelfth Night was played on 25 December 1917, two months to the day after the Revolution. A few months later, Nikolai Efros published a book about the First Studio. It was dedicated to The Cricket on the Hearth but the words Efros used to describe the atmosphere in which Dickens’s production had opened

  8. Twelfth annual US DOE low-level waste management conference

    International Nuclear Information System (INIS)

    1990-01-01

    The papers in this document comprise the proceedings of the Department of Energy's Twelfth Annual Low-Level Radioactive Waste Management Conference, which was held in Chicago, Illinois, on August 28 and 29, 1990. General subjects addressed during the conference included: mixed waste, low-level radioactive waste tracking and transportation, public involvement, performance assessment, waste stabilization, financial assurance, waste minimization, licensing and environmental documentation, below-regulatory-concern waste, low-level radioactive waste temporary storage, current challenges, and challenges beyond 1990

  9. MODELAGEM SISTÊMICA DE PROJETOS DE AEC EM UML

    Directory of Open Access Journals (Sweden)

    Rita Cristina Ferreira

    2007-11-01

    Full Text Available O uso intensivo de Sistemas de Informação é uma possível solução para a integração das atividades de projeto em AEC, permitindo que decisões sejam tomadas ainda na fase de projeto e, conseqüentemente, evitando-se retrabalhos em obra. Neste sentido, esforços têm sido realizados para padronizar conceitos e terminologias de AEC, permitindo a troca e armazenagem de informações, como a norma ISO 12006-2 e os padrões estabelecidos pelo IFC. Ambas são baseadas na linguagem EXPRESS, assim como é o padrão industrial STEP. Entretanto, as representações de informação usadas na indústria de produtos não são as mais adequadas para a Engenharia de Software, responsável pelo desenvolvimento de Sistemas de Informação, onde as representações semânticas envolvem não somente a representação estrutural da informação, mas também a representação comportamental. Este artigo contribui com uma visão de implementação em UML da informação de um projeto de AEC e tornam explícitas, sob a ótica do desenvolvimento de software, as relações semânticas existentes. Os resultados desta pesquisa foram obtidos através da realização de um estudo de caso de projeto de produção em CAD 3D dos subsistemas alvenaria e revestimento para um edifício residencial. A partir das observações do estudo de caso foi feita a modelagem em UML dos objetos pertinentes. O principal resultado obtido foi a representação explícita das interfaces entre objetos AEC.

  10. Proceedings of the twelfth Symposium of Atomic Energy Research

    International Nuclear Information System (INIS)

    Vidovszky, Istvan

    2002-11-01

    The present volume contains 45 papers, presented on the twelfth Symposium of Atomic Energy Research, held in Sunny Beach, Bulgaria, 22-28 September 2002. The papers are presented in their original form, i. e. no corrections or modifications were carried out. The content of this volume is divided into thematic groups: Core Monitoring, Surveillance and Testing, Safety Issues, Core Operation and Fuel Management, Spectral and Core Calculation Methods, Spent Fuel Transmutations and Decommissioning, Neutron Kinetics and reactor Dynamics Methods, Poster Session - according to the presentation sequence on the Symposium

  11. Twelfth cranial nerve involvement in Guillian Barre syndrome.

    Science.gov (United States)

    Nanda, Subrat Kumar; Jayalakshmi, Sita; Ruikar, Devashish; Surath, Mohandas

    2013-07-01

    Guillian Barre Syndrome (GBS) is associated with cranial nerve involvement. Commonest cranial nerves involved were the facial and bulbar (IXth and Xth). Involvement of twelfth cranial nerve is rare in GBS. We present a case of GBS in a thirteen years old boy who developed severe tongue weakness and wasting at two weeks after the onset of GBS. The wasting and weakness of tongue improved at three months of follow up. Brief review of the literature about XIIth cranial nerve involvement in GBS is discussed.

  12. Twelfth cranial nerve involvement in Guillian Barre syndrome

    OpenAIRE

    Subrat Kumar Nanda; Sita Jayalakshmi; Devashish Ruikar; Mohandas Surath

    2013-01-01

    Guillian Barre Syndrome (GBS) is associated with cranial nerve involvement. Commonest cranial nerves involved were the facial and bulbar (IXth and Xth). Involvement of twelfth cranial nerve is rare in GBS. We present a case of GBS in a thirteen years old boy who developed severe tongue weakness and wasting at two weeks after the onset of GBS. The wasting and weakness of tongue improved at three months of follow up. Brief review of the literature about XIIth cranial nerve involvement in GBS is...

  13. Twelfth cranial nerve involvement in Guillian Barre syndrome

    Directory of Open Access Journals (Sweden)

    Subrat Kumar Nanda

    2013-01-01

    Full Text Available Guillian Barre Syndrome (GBS is associated with cranial nerve involvement. Commonest cranial nerves involved were the facial and bulbar (IXth and Xth. Involvement of twelfth cranial nerve is rare in GBS. We present a case of GBS in a thirteen years old boy who developed severe tongue weakness and wasting at two weeks after the onset of GBS. The wasting and weakness of tongue improved at three months of follow up. Brief review of the literature about XIIth cranial nerve involvement in GBS is discussed.

  14. Twelfth annual US DOE low-level waste management conference

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    The papers in this document comprise the proceedings of the Department of Energy's Twelfth Annual Low-Level Radioactive Waste Management Conference, which was held in Chicago, Illinois, on August 28 and 29, 1990. General subjects addressed during the conference included: mixed waste, low-level radioactive waste tracking and transportation, public involvement, performance assessment, waste stabilization, financial assurance, waste minimization, licensing and environmental documentation, below-regulatory-concern waste, low-level radioactive waste temporary storage, current challenges, and challenges beyond 1990.

  15. Annual report: AEC Institute for Life Sciences, 1986

    International Nuclear Information System (INIS)

    1987-08-01

    The AEC-Institute for life sciences research programme can be divided into four divisions: experimental nuclear medicine, radiobiology, radiopharmacy and hormone receptor studies. The experimental nuclear medicine division investigates and undertakes new developments in nuclear diagnostics with a view to clinical application, especially developments in dataprocessing techniques and radiopharmaceuticals. Physiological, biochemical and pharmacological problems are also investigated by using tracers and nuclear diagnostic techniques. The radiobiology division is concerned with the development of biochemical techniques for determining radiosensitivity amongst radiation workers as well as clinical-biochemical, diagnostic procedures for identifying exposure to ionizing types of radiation (X- or gamma radiation). The hormone receptor division is concerned with the study of the role of steroid hormone receptors, steroids and carcinogenes in the etiology of breast cancer. Research projects as well as completed and ongoing research are listed in this report

  16. South Africa and the RERTR programme. Current status. An AEC perspective

    International Nuclear Information System (INIS)

    Ball, G.

    1999-01-01

    The Atomic Energy Corporation (AEC) of South Africa fully endorses the principles of the RERTR programme. To this end in 1994 the AEC, together with Argonne National Laboratory (ANL), undertook a study into the feasibility of converting the SAFARI-1 reactor to LEU silicide fuel. More details are given. Due to the commercial pressures on the AEC at that time, the AEC decided not to convert SAFARI-1 to LEU silicide fuel. The AEC did, however, undertake to reevaluate the situation periodically. Five years have passed since the detailed study of 1994 and the changing conditions now warrant another detailed study taking into account the current situation. A brief historical background is given on the RERTR activities in South Africa since 1993 followed by a summary of the current situation

  17. The International Geomagnetic Reference Field: the twelfth generation

    Science.gov (United States)

    Thebault, Erwan; Finlay, Christopher; The IGRF Working Group

    2015-04-01

    The IGRF is an internationally-agreed reference model of the Earth's magnetic field produced under the auspices of the International Association of Geomagnetism and Aeronomy. The IGRF-12 is the latest update of this well-known model which is used each year by many thousands of users for both industrial and scientific purposes. In October 2014, ten institutions worldwide have made contributions to the IGRF. These models were evaluated and the twelfth generation of the International Geomagnetic Reference Field (IGRF) was adopted in December 2014. In this presentation, we will report on the IGRF activities, briefly describe the candidate models, summarize the evaluation of models performed by different independent teams, show how the IGRF-12 models were calculated and finally discuss some of the main magnetic features of this new model.

  18. AEC sets five year nuclear safety research program

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The research by the government for the establishment of means of judging the adequacy of safety measures incorporated in nuclear facilities, including setting safety standards and collecting documents of general criteria, and the research by the industry on safety measures and the promotion of safety-related technique are stated in the five year program for 1976-80 reported by subcommittees, Atomic Energy Commission (AEC). Four considerations on the research items incorporated in the program are 1) technical programs relating to the safety of nuclear facilities and the necessary criteria, 2) priority of the relevant items decided according to their impact on circumstances, urgency, the defence-indepth concept and so on, 3) consideration of all relevant data and documents collected, and research subjects necessary to quantify safety measurement, and 4) consideration of technological actualization, the capability of each research body, the budget and the time schedule. In addition, seven major themes decided on the basis of these points are 1) reactivity-initiated accident, 2) LOCA, 3) fuel behavior, 4) structural safety, 5) radioactive release, 6) statistical method of safety evaluation, and 7) seismic characteristics. The committee has deliberated the appropriate division of researches between the government and the industry. A set of tables showing the nuclear safety research plan for 1976-80 are attached. (Iwakiri, K.)

  19. Le mythe comme détour dans Twelfth Night The Myth as a Diversion in Twelfth Night

    Directory of Open Access Journals (Sweden)

    Cécile Mauré

    2009-06-01

    Full Text Available Being only rarely mentioned in the text, the myth might seem an anecdotal and trivial detail. The study of the myth of Echo and Narcissus in Twelfth Night shows us however that it is a decisive element in the reading and the understanding of the play. The references are numerous and often implicit. The characters themselves alternately play the roles of Echo and Narcissus. The play is structured as if it were a mirror in which the characters endlessly duplicate each other and echo their own words. Shakespeare plays with the different versions of the myth that he often blends with subtlety. For the sake of comedy, he dares to parody and demythologize Ovid’s story. The myth seems to divert our attention from the direction of the text but closer analysis suggests the reverse and invites us to find the meaning of the play which can be seen as a real labyrinth.

  20. Design and realization of an AEC&AGC system for the CCD aerial camera

    Science.gov (United States)

    Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun

    2015-08-01

    An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.

  1. BIM Investment, Returns, and Risks in China’s AEC Industries

    OpenAIRE

    Jin, R; Hancock, CM; Tang, L; Wanatowski, D

    2017-01-01

    Building information modeling (BIM), the emerging digital technology, is undergoing increasing application in developing countries including China. Both the governmental policy and industry motivation have indicated that BIM is becoming the mainstream innovation in China’s construction industry. Nevertheless, one major concern lies in the uncertainty of BIM investment for architecture, engineering, and construction (AEC) firms. Specifically, AEC firms should have the knowledge of areas BIM in...

  2. IMPROVING THE HARD SKILLS AND SOFT SKILLS OF MADRASAH TEACHERS FOR DEALING ASEAN ECONOMIC COMMUNITY (AEC)

    OpenAIRE

    Laely Mahmudah

    2016-01-01

    ASEAN Economic Community (AEC) has been started rolling. Market competition, industry, and skilled workers, especially in the field of education are becoming increasingly stringent. Madrasah teachers as the front liners in the education process should improve the quality of human resources. Hard skills and soft skills of madrasah teachers must be improved to deal with the Asean Economic Community (AEC). Hard skills are academic skills that include pedagogic competence and professional compete...

  3. Improving The Hard Skills And Soft Skills Of Madrasah Teachers For Dealing ASEAN Economic Community (Aec)

    OpenAIRE

    Mahmudah, Laely

    2016-01-01

    ASEAN Economic Community (AEC) has been started rolling. Market competition, industry, and skilled workers, especially in the field of education are becoming increasingly stringent. Madrasah teachers as the front liners in the education process should improve the quality of human resources. Hard skills and soft skills of madrasah teachers must be improved to deal with the Asean Economic Community (AEC). Hard skills are academic skills that include pedagogic competence and professional compete...

  4. Design of 118 MHz twelfth harmonic cavity of APS PAR

    International Nuclear Information System (INIS)

    Kang, Y.W.; Kustom, R.L.; Bridges, J.F.

    1992-01-01

    Two radio frequency (RF) cavities are needed in the Positron Accumulator Ring (PAR) of the Advanced Photon Source. One is for the first harmonic frequency at 9.8 MHz, and the other is for the twelfth harmonic frequency at 118 MHz. This note reports on the design of the 118 MHz RF cavity. Computer models are used to find the mode frequencies, impedances, Q-factors, and field distributions in the cavity. The computer codes MAFIA, URMEL, and URMEL-T are useful tools which model and simulate the resonance characteristics of a cavity. These codes employ the finite difference method to solve Maxwell's equations. MAFIA is a three-dimensional problem solver and uses square patches to approximate the inner surface of a cavity. URMEL and URMEL-T are two-dimensional problem solvers and use rectangular and triangular meshes, respectively. URMEL-T and MAFIA can handle problems with arbitrary dielectric materials located inside the boundary. The cavity employs a circularly cylindrical ceramic window to limit the vacuum to the beam pipe. The ceramic window used in the modeling will have a wall thickness of 0.9 cm. This wall thickness is not negligible in determining the resonant frequencies of the cavity. In the following, results of two- and three-dimensional modeling of the cavities using the URMEL-T and MAFIA codes are reported

  5. Human Research Program Advanced Exercise Concepts (AEC) Overview

    Science.gov (United States)

    Perusek, Gail; Lewandowski, Beth; Nall, Marsha; Norsk, Peter; Linnehan, Rick; Baumann, David

    2015-01-01

    Exercise countermeasures provide benefits that are crucial for successful human spaceflight, to mitigate the spaceflight physiological deconditioning which occurs during exposure to microgravity. The NASA Human Research Program (HRP) within the Human Exploration and Operations Mission Directorate (HEOMD) is managing next generation Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation to Technology Readiness Level (TRL) 7 (ground prototyping and flight demonstration) for all exploration mission profiles from Multi Purpose Crew Vehicle (MPCV) Exploration Missions (up to 21 day duration) to Mars Transit (up to 1000 day duration) missions. These validated and optimized exercise countermeasures systems will be provided to the ISS Program and MPCV Program for subsequent flight development and operations. The International Space Station (ISS) currently has three major pieces of operational exercise countermeasures hardware: the Advanced Resistive Exercise Device (ARED), the second-generation (T2) treadmill, and the cycle ergometer with vibration isolation system (CEVIS). This suite of exercise countermeasures hardware serves as a benchmark and is a vast improvement over previous generations of countermeasures hardware, providing both aerobic and resistive exercise for the crew. However, vehicle and resource constraints for future exploration missions beyond low Earth orbit will require that the exercise countermeasures hardware mass, volume, and power be minimized, while preserving the current ISS capabilities or even enhancing these exercise capabilities directed at mission specific physiological functional performance and medical standards requirements. Further, mission-specific considerations such as preservation of sensorimotor function, autonomous and adaptable operation, integration with medical data systems, rehabilitation, and in-flight monitoring and feedback are being developed for integration with the exercise

  6. Twelfth European TRIGA users conference. Papers and abstracts

    International Nuclear Information System (INIS)

    2008-01-01

    The Twelfth European TRIGA Users Conference was held in Pitesti, Romania, on September 28 - October 1, 1992, under the sponsorship of the Institute for Nuclear Research. The papers which follow in this document are presented in the same order as listed in the Conference Program. All papers which were received for publication (44) have been included. Those papers which were presented but not received for publication are presented in abstract form (3). The European TRIGA9 Owners' Group was fortunate to be hosted by the owners and users of the world's largest TRIGA reactor - the 14-MW Romanian research and test reactor. For too many years it has been impossible to enjoy open interactions with the Romanian researchers. By hosting the 1992 European TRIGA Users' Conference in Romania, the Romanians accomplished a breakthrough in the exchange of TRIGA reactor technology. It was very interesting for the Conference attendees from the West to learn about the large scope of excellent work conducted in Romania, especially at the Institute of Nuclear Research in Pitesti. Similarly, it was fortunate that a large attendance of Romanian researchers from many institutes, universities, and government agencies could attend the Conference and interact with their counterparts from outside Romania. The proceedings of the conference were structured onto the following 6 subject matters: - Opening Session and Introduction; - Session I, Operating and Maintenance Experience (10 papers); - Session II, Reactor Physics And Fuel Utilization (11 papers); - Session III, Instrumentation and Control (5 papers); - Session IV, Irradiation Facilities, Experimental Accessories (8 papers); - Session V, Applications, New Development of TRIGA Concept (6 papers). The document is completed with the abstracts of 3 contributions. A number of 19 experts from Austria, Germany, Italy, United States, Turkey, Morocco, England, Slovenia and Albania, that use TRIGA reactors, and Romania attended the conference. The

  7. AIR RADIOACTIVITY MONITOR

    Science.gov (United States)

    Bradshaw, R.L.; Thomas, J.W.

    1961-04-11

    The monitor is designed to minimize undesirable background buildup. It consists of an elongated column containing peripheral electrodes in a central portion of the column, and conduits directing an axial flow of radioactively contaminated air through the center of the column and pure air through the annular portion of the column about the electrodes. (AEC)

  8. Minor Characters in William Shakespeare's Twelfth Night and A Midsummer Night's Dream

    Directory of Open Access Journals (Sweden)

    Zahraa Adnan Baqer

    2018-01-01

    Full Text Available This paper aims at discussing the role of the minor characters in William Shakespeare's Twelfth Night and A Midsummer Night's Dream. The study assumes that without the first group of minor characters, associated with Olivia, the play Twelfth Night would lose much of its humor, and without the second group, associated with Sebastian, the play would fall apart. On the other hand, in Shakespeare's A Midsummer Night's Dream minor characters play important roles, without them, the action dose not ran smoothly, or does not ran at all. The paper falls into three sections. Section one deals with the role of each minor character in Twelfth Night.  Section two focuses on the minor characters in A Midsummer Night's Dream. Section three is a conclusion which sums up the findings of the study.

  9. Special issue “International Geomagnetic Reference Field—the twelfth generation”

    DEFF Research Database (Denmark)

    Thébault, E.; Finlay, C. C.; Toh, H.

    2015-01-01

    This special issue of Earth, Planets and Space, synthesizes the efforts made during the construction of the twelfth generation of the International Geomagnetic Reference Field (IGRF-12) that was released online in December 2014 (http://www.ngdc.noaa.gov/IAGA/vmod/ igrf.html). The IGRF-12 is a ser......This special issue of Earth, Planets and Space, synthesizes the efforts made during the construction of the twelfth generation of the International Geomagnetic Reference Field (IGRF-12) that was released online in December 2014 (http://www.ngdc.noaa.gov/IAGA/vmod/ igrf.html). The IGRF-12...

  10. Design logistics performance measurement model of automotive component industry for srengthening competitiveness of dealing AEC 2015

    Science.gov (United States)

    Amran, T. G.; Janitra Yose, Mindy

    2018-03-01

    As the free trade Asean Economic Community (AEC) causes the tougher competition, it is important that Indonesia’s automotive industry have high competitiveness as well. A model of logistics performance measurement was designed as an evaluation tool for automotive component companies to improve their logistics performance in order to compete in AEC. The design of logistics performance measurement model was based on the Logistics Scorecard perspectives, divided into two stages: identifying the logistics business strategy to get the KPI and arranging the model. 23 KPI was obtained. The measurement result can be taken into consideration of determining policies to improve the performance logistics competitiveness.

  11. Purposive Teaching Styles for Transdisciplinary AEC Education: A Diagnostic Learning Styles Questionnaire

    Directory of Open Access Journals (Sweden)

    Sharifah Mazlina Syed Khuzzan

    2015-07-01

    Full Text Available With the progressive globalisation trend within the Architecture, Engineering, and Construction (AEC industry, transdisciplinary education and training is widely acknowledged as being one of the key factors for leveraging AEC organisational success. Conventional education and training delivery approaches within AEC therefore need a paradigm shift in order to be able to address the emerging challenges of global practices. This study focuses on the use of Personalised Learning Environments (PLEs to specifically address learners’ needs and preferences (learning styles within managed Virtual Learning Environments (VLEs. This research posits that learners can learn better (and be more readily engaged in managed learning environments with a bespoke PLE, in which the deployment of teaching and learning material is augmented towards their individual needs. In this respect, there is an exigent need for the Higher Educational Institutions (HEIs to envelop these new approaches into their organisational learning strategy. However, part of this process requires decision-makers to fully understand the core nuances and interdependencies of functions and processes within the organisation, along with Critical Success Factors (CSFs and barriers. This paper presents findings from the development of a holistic conceptual Diagnostic Learning Styles Questionnaire (DLSQ Framework, comprised of six interrelated dependencies (i.e. Business Strategy, Pedagogy, Process, Resources, Systems Development, and Evaluation. These dependencies influence pedagogical effectiveness. These finding contribute additional understanding to the intrinsic nature of pedagogy in leveraging transdisciplinary AEC training within organisations (to improve learner effectiveness. This framework can help organisations augment and align their strategic priorities to learner-specific traits.

  12. Basic data report for Drillhole AEC 7 (Waste Isolation Pilot Plant - WIPP)

    International Nuclear Information System (INIS)

    1983-01-01

    AEC 7 is a borehole drilled in western Lea County, New Mexico, in section 31, T.21S.,R.32E. AEC 7 was drilled to 3918 feet in 1974 by Oak Ridge National Laboratory; Sandia deepened the hole to 4732 ft in 1979. The borehole provided stratigraphic and lithologic information in the initial and final drilling. The borehole was used extensively for tests of borehole plugs and plugging operations. AEC 7 penetrated, in descending order, Holocene sands and Mescalero caliche (8 ft), Santa Rosa Sandstone (109 ft), Dewey Lake Red Beds (542 ft), Rustler Formation (325 ft), Salado Formation (2014 ft), Castile Formation (1521 ft), and the upper Bell Canyon Formation (197 ft). Cores were obtained from much of the borehole. An extensive suite of geophysical logs provides information on stratigraphy, lithology, and structure. Beds were in normal stratigraphic sequence and without structural deformation except in the lower Castile. Anhydrite II and Halite II appear to be repeated in the borehole. This section was penetrated during deepening by Sandia; the structural complication is consistent with deformation found nearby in ERDA 6. The potential site on which AEC 7 is located was abandoned in 1976 after ERDA 6 was drilled. The WIPP is a demonstration facility for the disposal of transuranic (TRU) waste from defense programs. The WIPP will also provide a research facility to investigate the interactions between bedded salt and high level wastes

  13. The Role of English Debating Tournament in the Face of the ASEAN Economy Community (AEC)

    Science.gov (United States)

    Husnawadi; Syamsudarni

    2016-01-01

    Since its establishment in the late 2015, the ASEAN Economic Community (AEC) with English as the official language has forced its participating countries to improve the quality of English language teaching, in the hope to prepare their people to be globally competitive, as the lack of English proficiency remains the main challenge across the…

  14. From Mars to Minerva: The origins of scientific computing in the AEC labs

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, R.W. [ERA Land Grant Professor of the History of Technology]|[Charles Babbage Institute, University of Minnesota, Minneapolis, Minnesota (United States)

    1996-10-01

    Although the AEC laboratories are renowned for the development of nuclear weapons, their largess in promoting scientific computing also had a profound effect on scientific and technological development in the second half of the 20th century. {copyright} {ital 1996 American Institute of Physics.}

  15. The role of high speed photography in plasma instability research on the AEC tokamak

    International Nuclear Information System (INIS)

    Fletcher, J.D.; Coster, D.P.; De Villiers, J.A.M.; Kotze, P.B.; Nothnagel, G.; O'Mahony, J.R.; Roberts, D.E.; Sherwell, D.

    1986-01-01

    High speed cine photography is a useful diagnostic aid for studying plasma behaviour and plasma surface interactions in fusion research devices like tokamaks. Such a system has been installed on the AEC tokamak. This paper reports some preliminary results obtained during typical plasma discharges

  16. Examination of CT-AEC when the positioning changes after planning of CT scanning

    International Nuclear Information System (INIS)

    Esaki, Tooru; Yamazaki, Shoichi

    2009-01-01

    CT-automatic exposure control (AEC) controls tube current collecting information of the subject from positioning shooting. Because of this, we consider that CT-AEC does not get to operate properly if the body position of the test subject changes after the positioning shooting. However, we often experience in body positions of test subjects after the positioning shooting. In cases like this, we measured by using a phantom again to see how they affect the tube current value and standard deviation (SD) value comparing them to the normal scan where a body position does not change. As a result of the measurement, there was an impact on CT-AEC that optimization of tube current becomes insufficient if the body position of a test subject changes. As the image quality is deteriorated and radiation exposure increases because of this, taking positioning shooting again is required on the part of users and it's desirable on the part of manufacturers to develop CT-AEC that can be controlled with high accuracy. (author)

  17. The Impact of Past Language Arts Teachers on the Reading Motivation of Twelfth Grade Students

    Science.gov (United States)

    Shepard, Courtney A.

    2017-01-01

    Adolescents' motivation to read continues to decline. The purpose of this embedded single case study was to explore adolescent reading motivation to determine some ways in which adolescents are motivated to read. Through purposeful sampling, the participants included seven twelfth grade students and three English Language Arts teachers in grades…

  18. The impact of the AEC mode of tube current on the dose at CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Kim, Kwang Cheol [Dept. of of Nuclear Engineering, Chosun University,Gwangju (Korea, Republic of)

    2016-11-15

    In this study, the automatic exposure control (AEC) modes of tube current (SIEMENSCare Dose 4D and GE AEC mode) that CT manufacturers are using was applied to neck, chest and abdomen in order to determine the difference in the respective dose parameters (CTDIvol, DLP and mSv) resulting from the dose reduction. Equipment in use at C university adopted Care Dose 4D of Siemens and AEC mode of General Electric (GE), and the x-ray exposure conditions were adjusted to be as identical as possible between the experiments. For the assessment of the dose reduction, the differences between the doses with and without the use of the tube current AEC mode by the respective manufacturer were measured for each body part including neck, chest and abdomen of a human phantom, Rando Phantom (Art-200x, Fluke Biomedical, USA). First, the assessment of SIEMENS-Care Dose 4D yielded the following results. At the neck, the automatic exposure control resulted in a 3.3% reduction in CTDIvol and DLP, and a 3% reduction in the effective dose, mSv, compared to manual exposure control. The automatic exposure control at the chest displayed the reduction in CTDIvol and DLP by 25.5%, and in the effective dose, mSv, by 25.4% compared to the manual exposure control. In case of abdomen, CTDIvol and DLP were shown to be reduced by 16%, and the effective dose (mSv) by 16.3% under the automatic exposure control compared to the manual exposure. Second, the assessment results of GE AEC mode are as follows. The automatic exposure control at the neck resulted in a 45.1% reduction in CTDIvol and DLP, and a 44.7% reduction in the effective dose (mSv) in comparison to the manual exposure control. At the chest, the automatic exposure control displayed a 47.6% reduction in CTDIvol and DLP, and a 47.5% reduction in the effective dose, mSv, compared to the manual exposure control. At the abdomen, it was shown that CTDIvol and DLP were reduced by 26.9%, and the effective dose (mSv) by 26.8% under the automatic

  19. The impact of the AEC mode of tube current on the dose at CT scans

    International Nuclear Information System (INIS)

    Moon, Il Bong; Dong, Kyung Rae; Kim, Kwang Cheol

    2016-01-01

    In this study, the automatic exposure control (AEC) modes of tube current (SIEMENSCare Dose 4D and GE AEC mode) that CT manufacturers are using was applied to neck, chest and abdomen in order to determine the difference in the respective dose parameters (CTDIvol, DLP and mSv) resulting from the dose reduction. Equipment in use at C university adopted Care Dose 4D of Siemens and AEC mode of General Electric (GE), and the x-ray exposure conditions were adjusted to be as identical as possible between the experiments. For the assessment of the dose reduction, the differences between the doses with and without the use of the tube current AEC mode by the respective manufacturer were measured for each body part including neck, chest and abdomen of a human phantom, Rando Phantom (Art-200x, Fluke Biomedical, USA). First, the assessment of SIEMENS-Care Dose 4D yielded the following results. At the neck, the automatic exposure control resulted in a 3.3% reduction in CTDIvol and DLP, and a 3% reduction in the effective dose, mSv, compared to manual exposure control. The automatic exposure control at the chest displayed the reduction in CTDIvol and DLP by 25.5%, and in the effective dose, mSv, by 25.4% compared to the manual exposure control. In case of abdomen, CTDIvol and DLP were shown to be reduced by 16%, and the effective dose (mSv) by 16.3% under the automatic exposure control compared to the manual exposure. Second, the assessment results of GE AEC mode are as follows. The automatic exposure control at the neck resulted in a 45.1% reduction in CTDIvol and DLP, and a 44.7% reduction in the effective dose (mSv) in comparison to the manual exposure control. At the chest, the automatic exposure control displayed a 47.6% reduction in CTDIvol and DLP, and a 47.5% reduction in the effective dose, mSv, compared to the manual exposure control. At the abdomen, it was shown that CTDIvol and DLP were reduced by 26.9%, and the effective dose (mSv) by 26.8% under the automatic

  20. Vitality Of Village Umkm In The Arena Of Asean Economic Community (Aec

    Directory of Open Access Journals (Sweden)

    Dhanny Septimawan Sutopo

    2016-12-01

    Full Text Available A horizon of expectation seems to be much brighter when the regional cooperation among the Southeast Asian countries intensify due to their meeting commitment of integration. The culmination of the regional cooperation commitment in Southeast Asia is an agreement to become a solid community within the framework of the Asean Community. One aim of the Asean Community is to form a joint economic community among the countries in Southeast Asia, commonly known as the Asean Economic Community (AEC. AEC opens space for the flow of goods and services from ASEAN member countries freely, including items that have been developed by Usaha Mikro Kecil dan Menengah (UMKM – Micro Small and Medium Enterprises. In Indonesia, especially in Malang, UMKM provide the foundation of the regional economic development. The implementation of AEC will slowly and surely give implications to UMKM and regional economy, more specifically the areas with less attention preparing for UMKM to face the Southeast Asian regional free market. It is an early gate to determine whether the position of this proved-to-be-resilient economic actors (read: UMKM will be involved or will be squashed to be a spectator when the other countries of the region make Indonesia as a new trading arena. This research will conduct a preliminary assessment towards the local government’s innovation in facing the implementation of AEC, primarily that relates to organizing UMKM at the local/village level. The purpose of this study is to gain an understanding in greater detail in accordance with the local government's response and strategies in Malang Raya to prepare village UMKM in dealing with the implementation of AEC. The study also attempts to find the initial design of strengthening the village UMKM that is adaptive to current regional and global trade liberalization. Field research will be conducted in Malang Regencies, Malang City, and Batu City, where all these areas have village UMKM that are

  1. Formerly utilized MED/AEC sites remedial action program: radiological survey of the Museum of Science and Industry, 57th Street and Lake Shore Drive, Chicago, Illinois. Final report

    International Nuclear Information System (INIS)

    1979-02-01

    From August 15, 1946 until July 15, 1953, ANL occupied part of the Museum of Science and Industry in Chicago; some handling of radioactive materials took place. In a radiation survey taken of the areas in 1977, instrument and smear surveys were made, and air and soil samples were counted. Results indicate there is no identifiable residual radioactivity remaining from MED/AEC operations during the period 1946 through 1953

  2. A/E/C Graphics Standard: Release 2.0 (formerly titled CAD Drafting Standard)

    Science.gov (United States)

    2015-08-01

    acronyms: • A/E/C – Architecture , Engineering, and Construction • BIM – Building Information Modeling • CAD – Computer-Aided Design • CIM – Civil...title GENERAL NOTES. General notes applicable to sheets for a particular discipline (e.g., architectural , electrical, mechanical) shall be located on...Filled fonts are used primarily for titles and on cover sheets. • Symbol font: This font should be used in cases where Greek symbols are

  3. Basic Data Report for Monitor Well AEC-7 (C-2742) Reconfiguration Activities

    International Nuclear Information System (INIS)

    2005-01-01

    The New Mexico Office of the State Engineer (OSE) permitted well AEC-7 as C-2742. This well has been part of the far-field monitoring network since 1974. The well was used to obtain water level elevations and hydraulic parameters from both the Bell Canyon Formation and the Culebra Member of the Rustler Formation. This basic data report provides a historical account of the well from the original installation to the current configuration.

  4. Prepare SME in Facing AEC 2015 through English Training Program to Obtain the Export Market

    Directory of Open Access Journals (Sweden)

    Rianto Nurcahyo

    2015-09-01

    or the effect of two nominal variables and to measure the relation strength of each variable with other nominal variable (C as the coefficient of contingency. From the chi square method, difference from the SME before and after the Export English course training is expected to be found. The training will use classroom method. The title of this study is prepare SME in Facing AEC 2015 through English training program to obtain the export market.

  5. THE READINESS OF SMES IN BULUNGAN TO FACE ASEAN ECONOMIC COMMUNITY (AEC

    Directory of Open Access Journals (Sweden)

    Nurus Soimah

    2017-11-01

    Full Text Available ASEAN Economic Community (AEC is formed on the basis of an agreement in order to create a relationship of closer cooperation among ASEAN countries. The agreement covers four strategic, namely: (1 the achievement of a single market and a unified production base, (2 a competitive economic region, (3 equitable economic growth, and (4 integrated with the global economy. This research aimed to identify the readiness of SMEs Facing the ASEAN Economic Community (AEC, which will begin to be realized in December 2015. This research is a qualitative descriptive research. The researcher took a case study on SMEs in Bulungan Regency by selecting informants by using Purposive Sampling. 36 SMEs domiciled in Bulungan Regency were taken as the research subject. The data used in this research was a combination of primary data obtained in the field through interviews and secondary data adapted from various sources as a reference for research writing. Data analysis techniques used was data reduction and validity techniques using triangulation. The result of the research shows that the problem of SMEs in Bulungan Regency is the problem of the production process, capital, marketing, and permit. Further research results indicate that Bulungan Regency Government has been trying to encourage the development of the SMEs, but the implementation of government policy is not maximized. Based on the conditions and problems faced by SMEs in Bulungan Regency, it is not ready to face the AEC.

  6. Variations of thermospheric composition according to AE-C data and CTIP modelling

    Directory of Open Access Journals (Sweden)

    H. Rishbeth

    2004-01-01

    Full Text Available Data from the Atmospheric Explorer C satellite, taken at middle and low latitudes in 1975-1978, are used to study latitudinal and month-by-month variations of thermospheric composition. The parameter used is the "compositional Ρ-parameter", related to the neutral atomic oxygen/molecular nitrogen concentration ratio. The midlatitude data show strong winter maxima of the atomic/molecular ratio, which account for the "seasonal anomaly" of the ionospheric F2-layer. When the AE-C data are compared with the empirical MSIS model and the computational CTIP ionosphere-thermosphere model, broadly similar features are found, but the AE-C data give a more molecular thermosphere than do the models, especially CTIP. In particular, CTIP badly overestimates the winter/summer change of composition, more so in the south than in the north. The semiannual variations at the equator and in southern latitudes, shown by CTIP and MSIS, appear more weakly in the AE-C data. Magnetic activity produces a more molecular thermosphere at high latitudes, and at mid-latitudes in summer. Key words. Atmospheric composition and structure (thermosphere – composition and chemistry

  7. Variations of thermospheric composition according to AE-C data and CTIP modelling

    Directory of Open Access Journals (Sweden)

    H. Rishbeth

    2004-01-01

    Full Text Available Data from the Atmospheric Explorer C satellite, taken at middle and low latitudes in 1975-1978, are used to study latitudinal and month-by-month variations of thermospheric composition. The parameter used is the "compositional Ρ-parameter", related to the neutral atomic oxygen/molecular nitrogen concentration ratio. The midlatitude data show strong winter maxima of the atomic/molecular ratio, which account for the "seasonal anomaly" of the ionospheric F2-layer. When the AE-C data are compared with the empirical MSIS model and the computational CTIP ionosphere-thermosphere model, broadly similar features are found, but the AE-C data give a more molecular thermosphere than do the models, especially CTIP. In particular, CTIP badly overestimates the winter/summer change of composition, more so in the south than in the north. The semiannual variations at the equator and in southern latitudes, shown by CTIP and MSIS, appear more weakly in the AE-C data. Magnetic activity produces a more molecular thermosphere at high latitudes, and at mid-latitudes in summer.

    Key words. Atmospheric composition and structure (thermosphere – composition and chemistry

  8. IMPROVING THE HARD SKILLS AND SOFT SKILLS OF MADRASAH TEACHERS FOR DEALING ASEAN ECONOMIC COMMUNITY (AEC

    Directory of Open Access Journals (Sweden)

    Laely Mahmudah

    2016-11-01

    Full Text Available ASEAN Economic Community (AEC has been started rolling. Market competition, industry, and skilled workers, especially in the field of education are becoming increasingly stringent. Madrasah teachers as the front liners in the education process should improve the quality of human resources. Hard skills and soft skills of madrasah teachers must be improved to deal with the Asean Economic Community (AEC. Hard skills are academic skills that include pedagogic competence and professional competence. How to improve the hard skills is to meet the pedagogic competence (ability to manage learning students and professional competence (the ability to master the learning material is broad and deep. Soft skills is the ability to organize themselves (intrapersonal skills, such as creativity, motivation, and self-contained and the ability to interact with others (interpersonal skills, such as communication, team building and adaptation to maximize performance. Soft skills include personal competence and social competence. Madrasah teachers should be able to change the mindset of a passenger became good driver. Professional madrasah teachers are teachers who have the balanced hard skills and soft skills, which can compete healthily in AEC era.

  9. Twelfth annual conference of the CFD Society of Canada (CFD 2004). Proceedings

    International Nuclear Information System (INIS)

    Khalid, M.; Chen, S.; McIlwain, S.

    2004-01-01

    The Twelfth Annual Conference of the CFD Society of Canada, CFD 2004, was held in Ottawa, Ontario from May 9-11, 2004. The proceedings consists of 24 sessions covering the following topics: fluid structure interactions; multiphase and multi-species flows; mesh methods; turbulence; DNS/LES; supersonic and hypersonic flows; heat transfer; combustion and detonation; flow physics; aerodynamics; applications; algorithms; environmental flows; magnetohydrodynamics and electrohydrodynamics; biofluids; and, combustion and smoke management

  10. Bodies That Don't Matter: Possibilities of Female Homoeroticism in Twelfth Night

    OpenAIRE

    松尾, 江津子

    2007-01-01

    This article attempts to consider (non-)representation of female same-sex love in William Shakespeare's Twelfth Night in the cultural and political context of early modern England. The first question here is whether female homoeroticism existed in early modern English society. Valerie Traub shows how female same-sex desire and sexual activity did exist in spite of the lack of their historical documents in early modern England. According to her, female homoerotic desire was regarded as“ insign...

  11. Designing learning apparatus to promote twelfth grade students’ understanding of digital technology concept: A preliminary studies

    Science.gov (United States)

    Marlius; Kaniawati, I.; Feranie, S.

    2018-05-01

    A preliminary learning design using relay to promote twelfth grade student’s understanding of logic gates concept is implemented to see how well it’s to adopted by six high school students, three male students and three female students of twelfth grade. This learning design is considered for next learning of digital technology concept i.e. data digital transmition and analog. This work is a preliminary study to design the learning for large class. So far just a few researches designing learning design related to digital technology with relay. It may due to this concept inserted in Indonesian twelfth grade curriculum recently. This analysis is focus on student difficulties trough video analysis to learn the concept. Based on our analysis, the recommended thing for redesigning learning is: students understand first about symbols and electrical circuits; the Student Worksheet is made in more detail on the assembly steps to the project board; mark with symbols at points in certain places in the circuit for easy assembly; assembly using relays by students is enough until is the NOT’s logic gates and the others that have been assembled so that effective time. The design of learning using relays can make the relay a liaison between the abstract on the digital with the real thing of it, especially in the circuit of symbols and real circuits. Besides it is expected to also enrich the ability of teachers in classroom learning about digital technology.

  12. Novel variant in the TP63 gene associated to ankyloblepharon-ectodermal dysplasia-cleft lip/palate (AEC) syndrome.

    Science.gov (United States)

    Gonzalez, Francisco; Loidi, Lourdes; Abalo-Lojo, Jose M

    2017-01-01

    Ankyloblepharon-ectodermal dysplasia-cleft lip/palate (AEC) syndrome is a disorder resulting from anomalous embryonic development of ectodermal tissues. There is evidence that AEC syndrome is caused by mutations in the TP63 gene, which encodes the p63 protein. This is an important regulatory protein involved in epidermal proliferation and differentiation. Genome sequencing was performed in DNA from peripheral blood leukocytes of a newborn with AEC syndrome and her parents. Variants were searched in all coding exons and intron-exon boundaries of the TP63 gene. A heterozygous missense variant (NM_003722.4:c.1063G>C (p.Asp355His) was found in the newborn patient. No variants were found in either of the parents. We identified a previously unreported variant in TP63 gene which seems to be involved in the somatic malformations found in the AEC syndrome. The absence of this variant in both parents suggests that the variant appeared de novo.

  13. Formerly utilized MED/AEC sites remedial action program. Radiological survey of The George Herbert Jones Chemical Laboratory, The University of Chicago, Chicago, Illinois, June 13-17, 1977

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Mayes, C.B.; Justus, A.L.

    1982-05-01

    A comprehensive radiological survey was conducted at George Herbert Jones Chemical Laboratory at the University of Chicago, Chicago, Illinois. Radiochemistry for the MED/AEC project was performed in this building in the 1940s. The building is now used as laboratories, offices, and classrooms. The survey was undertaken to determine the location and quantities of any radioactive materials remaining from the MED/AEC operations. Forty-three spots of contamination possibly resulting from MED/AEC occupancy in 17 rooms exceeded the allowable limits as given in the ANSI Standard N13.12. Under current use conditions, the potential for radiation exposure to occupants of this building from these sources of contamination is remote. Concentrations of radon daughters in the air of the building, as measured with grab-sampling techniques, were below the limit of 0.01 WL above background as given in the Surgeon General's Guidelines. No long-lived radionuclides were detected in any air sample. Concentrations of radionuclides in soil samples from near the laboratory generally indicated background levels. In order to reduce the potential for radiation exposure, remedial measures such as stabilization of the contamination in place would be applicable as a short-term measure. In order to reduce the risk in the event that building modifications take place in the future, health physics procedures and coverage are recommended. The long-term solution would involve decontamination by removal of the radioactive residues from the 17 rooms or areas where contamination possibly resulting from MED/AEC activities was detected

  14. Formerly utilized MED/AEC sites remedial action program. Radiological survey of Eckhart Hall, the University of Chicago, Chicago, Illinois, September 14, 1976-March 22, 1977

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Boggs Mayes, C.; Justus, A.L.

    1982-05-01

    A comprehensive radiological survey was conducted at the Eckhart Hall at the University of Chicago, Chicago, Illinois. General radiochemistry and/or physics research was performed at this facility during the MED/AEC era in the 1940s. The building is now used as laboratories, offices, and classrooms. Survey measurements included alpha and beta-gamma contamination determinations, both fixed and removable; beta-gamma exposure readings at contact and at 1 m (3 ft); estimates of radon-daughter concentrations in the air; and determination of concentrations of 137 Cs, the 232 Th decay chain, the 226 Ra decay chain, and uranium in the soil on the site. Thirteen spots of contamination were found to be fixed to or under existing surfaces and not readily available for transfer to other locations. Under current use conditions, the potential for radiation exposure to occupants of this building from these sources of contamination is remote. Concentrations of radon daughters in the air of the building were less than the limit of 0.01 Working Level (WL) above background. No long-lived radionuclides were detected in any air sample. Concentrations of radionuclides in soil samples collected around the facility indicated background levels. The presumed maximum potential internal radiation 50-year dose commitments from inhalation/ingestion of contamination remaining from MED/AEC activities were calculated to be less than 25% of the appropriate annual standards for an individual in an uncontrolled area. Remedial measures such as stabilization of the contamination in place would be applicable as a short-term measure. In order to reduce the risk in the event that building modifications take place in the future, health physics procedures and coverage are recommended. The long-term solution would involve decontamination by removal of the radioactive residues

  15. Assessment of patient dose reduction when using AEC technique in toshiba 64 MDCT

    International Nuclear Information System (INIS)

    Khojali, Wadah Mohamed Ali.

    2016-03-01

    The aim of research is to evaluate the efficiency of AEC (SUREDOSE) used in Toshiba CT scanner in reducing patient radiation dose. 107 patients were studied from four CT scanners. Scan factors and radiation dose received during abdominal CT scan was registered between the contract phases of abdominal CT scan, where the arterial contrast phases was done with Routine Manual Protocol i.e. fixed mA and kVp regardless patient age, weight and reason of scan, while the vinous phase done using AEC. The mA values were considerably less in vinous phase than in the arterial phase for all hospitals with exceptional to hospital 4 where the mA values had increased. There were no variations between the two phases in the other scan factors (kVp. pitch, slice thickness, scan length), which indicates that the software was mainly changing the mA values. The mA also showed wide variations during venous phase as a result of the varying mA applied by the AEC for the different patient ages and weights. The data collection has showed that, the application of SURDOSE decreases that average mA by 56.6%, 61%6 and 56.6 for hospitals 1, 2, and 3 respectively. The reduction of the average of the CTD1_vol were 54.2%. 64.1% in hospital 1.2. and 3 respectively. The average DLPs were also less by 57.1%. 62.8%. 57.5% in hospital, 2, and 3 respectively between the phases. In hospital 4 one raw of the CT detector was not functioning this has disturbed the SURDOSE software. Leading to increase of the mA values and hence the patient radiation dose mA, CTD1_vol and DLP in this hospital increased by 47.7%, 54.3% and 42.8% respectively. This highlighted the risk of not applying the AEC correctly. The non application of this software was only due to lake of knowledge how to use it and the benefits of dose reduction associated with it. Application of this software is very useful and operator should be trained to use it in all CT exams. (Author)

  16. Cigarette Smoking Trajectories From Sixth to Twelfth Grade: Associated Substance Use and High School Dropout.

    Science.gov (United States)

    Orpinas, Pamela; Lacy, Beth; Nahapetyan, Lusine; Dube, Shanta R; Song, Xiao

    2016-02-01

    The purpose of this longitudinal study was to identify distinct trajectories of cigarette smoking from sixth to twelfth grade and to characterize these trajectories by use of other drugs and high school dropout. The diverse sample for this analysis consisted of a cohort of 611 students from Northeast Georgia who participated in the Healthy Teens Longitudinal Study (2003-2009). Students completed seven yearly assessments from sixth through twelfth grade. We used semi-parametric, group-based modeling to identify groups of students whose smoking behavior followed a similar progression over time. Current smoking (past 30 day) increased from 6.9% among sixth graders to 28.8% among twelfth graders. Four developmental trajectories of cigarette smoking were identified: Abstainers/Sporadic Users (71.5% of the sample), Late Starters (11.3%), Experimenters (9.0%), and Continuous Users (8.2%). The Abstainer/Sporadic User trajectory was composed of two distinct groups: those who never reported any tobacco use (True Abstainers) and those who reported sporadic, low-level use (Sporadic Users). The True Abstainers reported significantly less use of alcohol and other drugs and lower dropout rates than students in all other trajectories, and Sporadic Users had worse outcomes than True Abstainers. Experimenters and Continuous Users reported the highest drug use. Over one-third of Late Starters (35.8%) and almost half of Continuous Users (44.4%) dropped out of high school. Cigarette smoking was associated with behavioral and academic problems. Results support early and continuous interventions to reduce use of tobacco and other drugs and prevent high school dropout. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Special issue “International Geomagnetic Reference Field—the twelfth generation”

    OpenAIRE

    Thébault, E.; Finlay, C. C.; Toh, H.

    2015-01-01

    This special issue of Earth, Planets and Space, synthesizes the efforts made during the construction of the twelfth generation of the International Geomagnetic Reference Field (IGRF-12) that was released online in December 2014 (http://www.ngdc.noaa.gov/IAGA/vmod/ igrf.html). The IGRF-12 is a series of standard mathematical models describing the large scale internal part of the Earth’s magnetic field between epochs 1900.0 and 2015.0 with a forecast to epoch 2020.0. This activity has been main...

  18. Twelfth symposium on biotechnology for fuels and chemicals: Program and abstracts

    International Nuclear Information System (INIS)

    Scheitlin, F.M.

    1990-01-01

    This report is the program and abstracts of the twelfth symposium on biotechnology for fuels and chemicals, held on May 7--11, 1990, at Gatlinburg, Tennessee. The symposium, sponsored by the Department of Energy, Oak Ridge National Laboratory, Solar Energy Research Institute, Badger Engineers, Inc., Gas Research Institute, and American Chemical Society, consists of five sessions: Session 1, thermal, chemical, and biological processing; Session 2 and 3, applied biological research; Session 4, bioengineering research; and Session 5, biotechnology, bioengineering, and the solution of environmental problems. It also consists of a poster session of the same five subject categories

  19. Twelfth symposium on biotechnology for fuels and chemicals: Program and abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Scheitlin, F.M. (ed.)

    1990-01-01

    This report is the program and abstracts of the twelfth symposium on biotechnology for fuels and chemicals, held on May 7--11, 1990, at Gatlinburg, Tennessee. The symposium, sponsored by the Department of Energy, Oak Ridge National Laboratory, Solar Energy Research Institute, Badger Engineers, Inc., Gas Research Institute, and American Chemical Society, consists of five sessions: Session 1, thermal, chemical, and biological processing; Session 2 and 3, applied biological research; Session 4, bioengineering research; and Session 5, biotechnology, bioengineering, and the solution of environmental problems. It also consists of a poster session of the same five subject categories.

  20. AEC sets basic policy line on treatment and disposal of radioactive waste

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The AEC's new policy line for the treatment and disposal of radioactive wastes is explained with three tables added. The first table was prepared by MITI's Nuclear Fuel Advisory Committee regarding the projections on the amounts of radioactive wastes to be discharged from nuclear power plants, fuel fabrication plants and reprocessing plants, and the other two tables were made by the AEC committee on technical development of radioactive waste management, the one proposed the developmental steps necessary for establishing waste management technologies, and the other showed the related research and development items with target time schedule. The proper treatment and disposal of radioactive waste S are the problems that have to be resolved prior to the full development and utilization of nuclear energy. The Atomic Energy Commission set up a committee on July 29, 1975, to discuss the technologies on the management of radioactive wastes. The principle essential to the radioactive waste management was set, and it is desirable that this principle is put into practice with the cooperation and understanding of the people and all parties concerned. The countermeasures proposed will be subject to review yet as the technology makes further progress and they are as follows: on the high level radioactive waste management and the low-and intermediate-level radioactive waste management, the basic idea, targets and measures are given, and the methods for promoting experimental ocean dumping of low level radioactive wastes are proposed. (Iwakiri, K.)

  1. Agribusiness entrepreneurship development strategy in East Java for welcoming ASEAN Economic Community (AEC era

    Directory of Open Access Journals (Sweden)

    Dewie Tri Wijayati

    2016-07-01

    Full Text Available Facing the implementation of ASEAN Economic Community (AEC at the end of 2015 requires strategic measures to make Indonesia ready to compete with other nations in ASEAN. East Java Province has great potentials and contributions in the national agribusiness. Establishing agribusiness in East Java towards increased competitiveness is the right step to welcome AEC 2015. This research attempts to study the appropriate model of agribusiness development strategy for East Java. The selection of strategy model is expected to prepare a strong and competitive economy in East Java. Through three principles of data analysis model of Miles and Huberman with the emphasis on data collection, data display, and verification, this study also used a variety of data collection techniques and verifications such as Focus Group Discussion (FGD, observation, and others. This research was conducted in four regions as the focus of the study area: Probolinggo District, Sidoarjo District, Pasuruan District and the City of Batu. The results provide the following conclusions: (a the agribusiness development strategy in East Java should be done with the target approach. This means that the introduction to the target is the most important factors to determine the strategy to be implemented; (b the role of the government is highly important and strategic in developing agribusiness in East Java. These can be implemented through a variety of program models that are tailored to the target.

  2. Knowledge Management Practice in Two Australian Architecture-Engineering-Construction (AEC Companies

    Directory of Open Access Journals (Sweden)

    Patrick Zou

    2012-11-01

    Full Text Available Knowledge management (KM could be described as a management system that supports the creation, sharing and retrieving of valued information, expertise and insight within and across communities of people and related organizations using information and communication technologies and hence it is a combination of the effective application of information technlogy and management of human resources. KM is becoming a core competitive factor in construction operations. This paper presents the results of two case studies of KM practices in large AEC (architecture, engineering and construction companies through desk-top study and semi-structured interviews. The results indicate that implementing KM in AEC companies leads to competitive advantages and improved decision-making, problem solving and business performance. The results also indicateed that while technology plays an important role, top management commitment, total employee involvement, performance assessment and the culture of knowledge-learning and sharing must be considered when implementing KM. Therefore it is suggested that the implementation of KM should incorporate the company's vision, work processes, technology and culture, to improve the ability of knowledge creating, capturing, sharing, retrieving and ultimately, to improve the company's competitive advantage, decision making, problem solving and innovation.

  3. United States Air Force Statistical Digest, Fiscal Year 1957. Twelfth Edition

    Science.gov (United States)

    1957-09-30

    ACCIIENrS CAUSING FACTORS td AU" PRI AI.L PRJ ALL PRI ALL PRI ALL PRI ALL PRI SEcoND QI.IARTER (CONI" D) nmER • (CONT’D) Jet ~ (cant’d) B-52...unobllga:ted balancea tranaterred to the Treasury and \\Ulll~ted b&1&ncea at ~.1.ng ~tions tranaterred ’to "Mit account.a.. , td CUb tral:aterred traD...8217~ ~ 4𔃻 !!&f 5,806-----p:g6F . ,1 150 l,303 1,951 RT-33. 460 99 97 150 114 T-6. 9,733 l,2B1 2,928 2,416 3,108 T-33 . 3, l53 795 838 887 633 OURKEY 124

  4. Searching for the Exit in a Maze? Or Setting Sail for New Horizons? Metaphors by Twelfth Grade Students for Learning Mathematics

    Science.gov (United States)

    Guner, Necdet

    2013-01-01

    This study examines and classifies the metaphors that twelfth grade students formulated to describe the concept of "learning mathematics". The sample of the study consists of 669 twelfth grade students (317 female, 352 male) of two Anatolian and two vocational high schools located in the city center of Denizli. The following questions…

  5. Idiopathic Ninth, Tenth, and Twelfth Cranial Nerve Palsy with Ipsilateral Headache: A Case Report

    Directory of Open Access Journals (Sweden)

    Sun Seung-Ho

    2012-12-01

    Full Text Available Objective: This case report is to report the effect of Korean traditional treatment for idiopathic ninth, tenth, and twelfth cranial nerve palsy with ipsilateral headache. Methods: The medical history and imaging and laboratory test of a 39-year-old man with cranial palsy were tested to identify the cause of disease. A 0.2-mL dosage of Hwangyeonhaedoktang pharmacopuncture was administered at CV23 and CV17, respectively. Acupuncture was applied at P06, Li05, TE05, and G37 on the right side of the body. Zhuapiandutongbang (左偏頭痛方 was administered at 30 minutes to 1 hour after mealtime three times a day. The symptoms were investigated using Visual Analogue Scale (VAS. Results: The results of magnetic resonance imaging (MRI, computed tomography (CT, and laboratory tests were normal. The medical history showed no trauma, other illnesses, family history of diseases, medications, smoking, drinking and so on. All symptoms disappeared at the 10th day of treatment. Conclusion: Korean traditional treatment such as acupuncture, pharmcopuncture, and herbal medicine for the treatment of ninth, tenth, and twelfth cranial nerve palsy of unknown origin is suggested to be effective even though this conclusion is based on a single.

  6. Conference Report: International Research Symposium on Ankyloblepharon-Ectodermal Defects-Cleft Lip and/or Palate (AEC) Syndrome

    Science.gov (United States)

    Fete, Mary; vanBokhoven, Hans; Clements, Suzanne; McKeon, Frank; Roop, Dennis R.; Koster, Maranke I.; Missero, Caterina; Attardi, Laura D.; Lombillo, Vivian A.; Ratovitski, Edward; Julapalli, Meena; Ruths, Derek; Sybert, Virginia P.; Siegfried, Elaine C.; Bree, Alanna F.

    2009-01-01

    Ankyloblepharon-Ectodermal Defects-Cleft Lip/Palate (AEC) Syndrome (Hay-Wells syndrome, MIM #106220) is a rare autosomal dominant ectodermal dysplasia syndrome. It is due to mutations in the p63 gene, known to be a regulatory gene with many downstream gene targets. TP63 is important in the differentiation and proliferation of the epidermis, as well as many other processes including limb and facial development. It is also known that mutations in p63 lead to skin erosions. These erosions, especially on the scalp, are defining features of AEC syndrome and cause significant morbidity and mortality in these patients. It was this fact that led to the 2003 AEC Skin Erosion Workshop. That conference laid the groundwork for the International Research Symposium for AEC Syndrome held at Texas Children's Hospital in 2006. The conference brought together the largest cohort of individuals with AEC syndrome, along with a multitude of physicians and scientists. The overarching goals were to define the clinical and pathologic findings for improved diagnostic criteria, to obtain tissue samples for further study and to define future research directions. The symposium was successful in accomplishing these aims as detailed in this conference report. Following our report, we also present eleven manuscripts within this special section that outline the collective clinical, pathologic and mutational data from eighteen individuals enrolled in the concurrent Baylor College of Medicine IRB-approved protocol: Characterization of AEC syndrome. These collaborative findings will hopefully provide a stepping stone to future translational projects of p63 and p63-related syndromes. PMID:19353643

  7. [Analysis of Koch phenomenon of Mycobacterium tuberculosis-infected guinea pigs vaccinated with recombinant tuberculosis vaccine AEC/BC02].

    Science.gov (United States)

    Lu, J B; Cheng, B W; Deng, H Q; Su, C; Shen, X B; Du, W X; Yang, L; Wang, G Z; Xu, M

    2016-07-01

    To observe the Koch phenomenon of Mycobacterium tuberculosis(MTB)-infected guinea pigs after vaccinated with killed H37Ra bacteria or tuberculosis vaccine candidate AEC/BC02. Eighteen guinea pigs were challenged subcutaneously with 5.0×10(3) CFU MTB and after 40 days were divided into 3 groups (6 per group): NS group, AEC/BC02 group and H37Ra group, which were injected intramuscularly 3 times at 1 day interval with normal saline, AEC/BC02 vaccine and killed H37Ra bacteria respectively. Three weeks after the first vaccination, all guinea pigs were sacrificed to evaluate gross pathological scores for liver, spleen and lung, bacterial loads in lung and spleen, and lung inflammation. The gross pathological score in H37Ra group (48±26) was lower than that in NS group(62±15), but the difference was not significant (t=1.093, P=0.300). The AEC/BC02 group had a significantly lower gross pathological score (36±15) than NS group (t=2.980, P=0.014). No significant difference between H37Ra group and AEC/BC02 group was observed (t=1.009, P=0.337). The spleen bacterial load [(5.31±0.80) log10 CFU]in H37Ra group was slightly lower than that in NS group[(5.57±0.75) log10 CFU] but the difference was not significant (t=1.581, P=0.574). In AEC/BC02 group bacterial load in the spleen was (4.64±0.64) log10 CFU and significantly lower than NS group (t=2.306, P=0.044) and no significant difference between H37Ra group and AEC/BC02 group was observed (t=1.602, P=0.140). Meanwhile, the lung bacterial load in AEC/BC02 group was (3.71±1.01) log10 CFU and in H37Ra group was (3.82±1.25) log10 CFU. Compared to (4.15±0.69) log10 CFU in the NS group, no significant differences were found (t=0.881, P=0.399; t=0.566, P=0.584, respectively). For the lung inflammation, the inflamed areas in H37Ra group were significantly larger [(33.0±4.4%)] than those in both NS group [(14.8±8.4) %, t=4.719, P=0.001] and AEC/BC02 group [(14.8±8.4) %, t=3.616, P=0.005], and no significant differences were

  8. 75 FR 11116 - Certain Pasta from Italy: Notice of Amended Final Results of the Twelfth Antidumping Duty...

    Science.gov (United States)

    2010-03-10

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-818] Certain Pasta from Italy... certain pasta from Italy for the period of review (POR) of July 1, 2007, through June 30, 2008. See Certain Pasta from Italy: Notice of Final Results of the Twelfth Administrative Review, 75 FR 6352...

  9. Solution structure of the twelfth cysteine-rich ligand-binding repeat in rat megalin

    International Nuclear Information System (INIS)

    Wolf, Christian A.; Dancea, Felician; Shi Meichen; Bade-Noskova, Veronika; Rueterjans, Heinz; Kerjaschki, Dontscho; Luecke, Christian

    2007-01-01

    Megalin, an approx. 600 kDa transmembrane glycoprotein that acts as multi-ligand transporter, is a member of the low density lipoprotein receptor gene family. Several cysteine-rich repeats, each consisting of about 40 residues, are responsible for the multispecific binding of ligands. The solution structure of the twelfth cysteine-rich ligand-binding repeat with class A motif found in megalin features two short β-strands and two helical turns, yielding the typical fold with a I-III, II-V and IV-VI disulfide bridge connectivity pattern and a calcium coordination site at the C-terminal end. The resulting differences in electrostatic surface potential compared to other ligand-binding modules of this gene family, however, may be responsible for the functional divergence

  10. DE TESTIBUS TRACTATURI: A LATE TWELFTH-CENTURY ITALIAN CANONISTIC TREATISE ON LEGAL PROCEDURE

    Directory of Open Access Journals (Sweden)

    Bruce C. Brasington

    2017-06-01

    Full Text Available De testibus tractaturi, an unedited late twelfth-century, southern Italian treatise, draws on both Gratian’s Decretum and decretals of Pope Alexander III to consider question concerning witnesses. It may also be influenced to some degree by the Summa of Simon of Bisignano. There is no evidence of any reliance on civilian authors. In considering the exceptio contra personam testis, it raises the question of whether testimony given by a witness who later died before trial remained valid. This subject is rarely treated in the early canonistic ordines iudiciorum. The author’s application of a letter of Alexander III to Bishop Roger of Worchester (JL 13162 to this question appears to be unusual, perhaps unique, and sheds light on how the early ius commune evaluated evidence.

  11. Proceedings of the twelfth international symposium on remote sensing of environment

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    This is the third of three volumes of the proceedings of the Twelfth International Symposium on Remote Sensing of Environment, held 20 to 26 April 1978 in Manila, Philippines. This symposium is part of a continuing program investigating current activities in the field of remote sensing. The meeting is intended to promote increased international cooperation in research, development and application of this technology, and to stimulate an exchange of information on all aspects of this multidisciplinary field through the presentation of reports on work planned, in progress or completed. Presentations include those concerned with the utilization of this technology in various national and international programs as well as in numerous applications for monitoring and managing the earth's resources and man's global environment. Ground-based, airborne, and spaceborne sensor systems and both manual and machine-assisted data analysis and interpretation are included. All papers included in their entirety were abstracted and indexed for EDB/ERA.

  12. Minutes of the twelfth INDC meeting, Vienna, 5-9 October 1981

    International Nuclear Information System (INIS)

    Yiftah, S.

    1982-08-01

    The Twelfth Meeting of the INDC was held at IAEA Headquarters in Vienna from 5-9 October 1981. The meeting was attended by 13 committee members (member from Australia excused), six advisers and three observers from 14 Member States and two international organisations. The committee reviewed the nuclear data activities of the IAEA, in Member States and in nuclear data centres during the period since its Eleventh Meeting in Vienna in June 1980. It also discussed and reviewed in detail the Agency's future nuclear data programme for the period 1982-84. In general, the IAEA nuclear data programme reflects the trends discussed and detailed at the 11th INDC Meeting. The official minutes include summaries of the discussions of the agenda items, full reports of subcommittees, list of actions, together with lists of participants and subcommittee membership

  13. Occupational exposures at nuclear power plants. Twelfth annual report of the Isoe programme, 2002

    International Nuclear Information System (INIS)

    2004-01-01

    The Information System on Occupational Exposure (ISOE) was created by the OECD Nuclear Energy Agency in 1992 to promote and co-ordinate international co-operative undertakings in the area of worker protection at nuclear power plants. The ISOE Programme provides experts in occupational radiation protection with a forum for communication and exchange of experience. The ISOE databases enable the analysis of occupational exposure data from the 465 commercial nuclear power plants participating in the Programme (representing some 90 per cent of the world's total operating commercial reactors). The Twelfth Annual Report of the ISOE Programme summarises achievements made during 2002 and compares annual occupational exposure data. Principal developments in ISOE participating countries are also described. (author)

  14. Eleventh ITER negotiations meeting (N-11) and twelfth negotiators' standing sub-group meeting (NSSG-12)

    International Nuclear Information System (INIS)

    Luo Delong

    2005-01-01

    The Eleventh ITER Negotiations Meeting (N-11) and the Twelfth Negotiators' Standing Sub-Group (NSSG-12 convened on October 19-25, 2005 at the Kempinski Hotel Chengdu, Sichuan Province. China was the host of this meeting. Delegations from China, the European Union, Japan, the Republic of Korea, the Russian Federation and the United States of America, as well as members from the International Team, met there to continue their work to reach agreement on the joint implementation of the ITER international fusion energy R and D project. The delegations accepted the Vice Minister of Science and Technology, Mr. LIU Yanhua, and State Councillor, Mr. SHI Dinghuan as Moderators for N-11 and NSSG-12, respectively, and Mr. LUO Delong as Secretary for both meetings. At the Meeting, delegates discussed and made substantial progress on a full range of legal, technical, and administrative topics, including staffing for ITER, policies for managing the project and its procurements, and the continuing joint drafting of the agreement on establishing the international ITER Organization to implement the project. Delegates also explored the possibility of India joining the Negotiations. In the light of the reports presented to the Meeting from the recent joint exploratory mission to India, delegates identified a series of steps for the near future leading towards a possible agreement among all the Parties to India's accession. The Negotiations Meeting also discussed the progress report of NSSG and forward planning and future tasks. The Negotiators agreed that substantial progress was made on all topics, and delegations are optimistic that the Joint Implementation Agreement and related Annexes and instruments could be initialed in spring of 2006. As decided by all delegations, the next Twelfth ITER Negotiations Meeting will be held in Korea on 6 December, 2005

  15. Description of radiological problems at inactive uranium mill sites and formerly utilized MED/AEC sites

    International Nuclear Information System (INIS)

    Jacobs, D.G.; Dickson, H.W.

    1979-02-01

    During the early years of development of the nuclear program in the United States, more than a hundred sites were used by the Manhattan Engineer District (MED), and the U.S. Atomic Energy Commission (AEC), and/or its uranium suppliers. Many of these sites are no longer used for such activities, but in many cases, the real estate remains contaminated with radioactivity and can be a potential source of exposure to members of the general public. In addition, 22 inactive uranium mill tailings sites exist in the western part of the United States. Radioactive contamination conditions range from slight contamination on the surfaces of buildings and equipment to extensive contamination of the subsoil. The Department of Energy is conducting a program to assure that adequate precautions are taken in the management of these properties to provide the cost-effective protection of public health while permitting further use of land and other resources. Several issues which should be considered in the development of an effective policy for long-term management of such properties are identified

  16. Description of radiological problems at inactive uranium mill sites and formerly utilized MED/AEC sites

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, D.G.; Dickson, H.W.

    1979-02-01

    During the early years of development of the nuclear program in the United States, more than a hundred sites were used by the Manhattan Engineer District (MED), and the U.S. Atomic Energy Commission (AEC), and/or its uranium suppliers. Many of these sites are no longer used for such activities, but in many cases, the real estate remains contaminated with radioactivity and can be a potential source of exposure to members of the general public. In addition, 22 inactive uranium mill tailings sites exist in the western part of the United States. Radioactive contamination conditions range from slight contamination on the surfaces of buildings and equipment to extensive contamination of the subsoil. The Department of Energy is conducting a program to assure that adequate precautions are taken in the management of these properties to provide the cost-effective protection of public health while permitting further use of land and other resources. Several issues which should be considered in the development of an effective policy for long-term management of such properties are identified.

  17. Basic data report for drillhole AEC 8 (Waste Isolation Pilot Plant - WIPP)

    International Nuclear Information System (INIS)

    1983-01-01

    AEC 8 was originally drilled in 1974 to a depth of 3028 ft by Oak Ridge National Laboratory as part of the initial investigations of a site for radioactive waste disposal. In 1976, Sandia National Laboratories deepened the borehole from the top of the Castile Formation into the Bell Canyon Formation to test the hydraulic properties of the Bell Canyon. The borehole encountered in descending order Holocene sands (20 ft), Mescalero caliche (6 ft), Santa Rosa Sandstone (143 ft), Dewey Lake Redbeds (491 ft), Rustler Formation (322 ft), Salado Formation (1990 ft), Castile Formation (1335 ft), and the upper Bell Canyon Formation (603 ft). The borehole stratigraphy is in normal order and there is no significant deformation. An extensive suite of geophysical logs provides information on the lithology and stratigraphy. The potentiometric surfaces of Bell Canyon fluid-bearing zones are 550 ft (for the zone at 4821 ft to 4827 ft) and 565 ft below land surface (for the zone at 4844 to 4860 ft). The WIPP is a demonstration facility for the disposal of transuranic (TRU) waste from defense programs. The WIPP will also provide a research facility to investigate the interactions between bedded salt and high level wastes

  18. Second Annual AEC Scientific Computer Information Exhange Meeting. Proceedings of the technical program theme: computer graphics

    Energy Technology Data Exchange (ETDEWEB)

    Peskin,A.M.; Shimamoto, Y.

    1974-01-01

    The topic of computer graphics serves well to illustrate that AEC affiliated scientific computing installations are well represented in the forefront of computing science activities. The participant response to the technical program was overwhelming--both in number of contributions and quality of the work described. Session I, entitled Advanced Systems, contains presentations describing systems that contain features not generally found in graphics facilities. These features can be roughly classified as extensions of standard two-dimensional monochromatic imaging to higher dimensions including color and time as well as multidimensional metrics. Session II presents seven diverse applications ranging from high energy physics to medicine. Session III describes a number of important developments in establishing facilities, techniques and enhancements in the computer graphics area. Although an attempt was made to schedule as many of these worthwhile presentations as possible, it appeared impossible to do so given the scheduling constraints of the meeting. A number of prospective presenters 'came to the rescue' by graciously withdrawing from the sessions. Some of their abstracts have been included in the Proceedings.

  19. Feasibility study on an integrated AEC-grid device for the optimization of image quality and exposure dose in mammography

    Science.gov (United States)

    Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang

    2017-10-01

    Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.

  20. SU-E-I-34: Evaluating Use of AEC to Lower Dose for Lung Cancer Screening CT Protocols

    International Nuclear Information System (INIS)

    Arbique, G; Anderson, J; Guild, J; Duan, X; Malguria, N; Omar, H; Brewington, C; Zhang, D

    2015-01-01

    Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD) image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems

  1. LAW REFORM OF SMALL AND MEDIUM ENTREPRISES (SMEs AND EQUITABLE COOPERATIVE FOR COMPETITIVENESS IMPROVEMENT IN AEC ERA

    Directory of Open Access Journals (Sweden)

    Koesrianti Koesrianti

    2017-02-01

    Full Text Available Small Medium Entreprises (SMEs and Cooperative have not received a proper law protection in facing trade liberation of ASEAN Economic Community (AEC and economic globalized world. In 2015 AEC has been established that would bring a huge change in Southeast Asia regionS and definitely will have a wide impact to business people in Indonesia. SMEs and Cooperative contribute to more than 90 percent of total Indonesian national economy. However, they are weak on investment and information technology and management skill as well as competition law among ASEAN Member States. Economic policies do not give a sufficient protection to SMEs and Cooperative. This article tries to seek solutions for SMEs problems especially their legal structure in order to enhance their competitiveness. This article argues that the government can provide legal protection by reforming SMEs economic sectors similar to the AEC’s priority sectors by which the Indonesian’ SMEs would become world class corporate.  Keywords: Cooperative, AEC, legal reform, SMEs

  2. Electron and ion temperatures: a comparison of ground-based incoherent scatter and AE-C satellite measurements

    International Nuclear Information System (INIS)

    Benson, R.F.; Bauer, P.; Brace, L.H.; Carlson, H.C.; Hagen, J.; Hanson, W.B.; Hoegy, W.R.; Torr, M.R.; Wickwar, V.B.

    1977-01-01

    The Atmosphere Exploere-C satellite (AE-C) is uniquely suited for correlative studies with ground-based stations because its on-board propulsion system enables a desired ground station overflight condition to be maintained for a period of several weeks. It also provides the first low-altitude (below 260 km) comparison of satellite and incoherent scatter electron and ion temperatures. More than 40 comparisons of remote and in situ measurements were made by using data from AE-C and four incoherent scatter stations (Arecibo, Chatanika, Millstone Hill, and St. Santin). The results indicate very good agreement between satellite and ground measurements of the ion temperature, the average satellite retarding potential analyzer temperatures differing from the average incoherent scatter temperatures by -2% at St. Santin, +3% at Millstone Hill, and +2% at Arecibo. The electron temperatures also agree well, the average satellite temperatures exceeding the average incoherent scatter temperatures by 3% at St. Santin, 2% at Arecibo, and 11% at Millstone Hill. Several temperature comparisons were made between AE-C and Chatanika. In spite of the highly variable ionosphere often encountered at this high-latitude location, good agreement was obtained between the in situ and remote measurements of electron and ion temperatures. Longitudinal variations are found to be very important in the comparisons of electron temperature in some locations. The agreement between the electron temperatures is considerably better than that found in some earlier comparisons involving satellities at higher altitudes

  3. ANALISIS SEBARAN RADIONUKLIDA PADA KONDISI NORMAL UNTUK REAKTOR AEC 1000 MW

    Directory of Open Access Journals (Sweden)

    Sri Kuntjoro

    2015-03-01

    Full Text Available Telah dilakukan analisis sebaran radionuklida pada reaktor daya Atomic Energy Agency (AEC 3568 MWTh, setara dengan 1000 Mwe untuk kondisi operasi normal. Analisis dilakukan untuk dua reaktor yang terpisah sejauh 500 m dan sudut 90o satu dengan yang lain. Langkah awal dalam melakukan analisis adalah menentukan suku sumber reaktor menggunakan program komputer ORIGEN2 dan EMERALD NORMAL. ORIGEN2 digunakan untuk menentukan inventori radionuklida yang terdapat di reaktor. Selanjutnya dengan dengan menggunakan program EMERALD NORMAL dihitung suku sumber yang sampai ke cerobong reaktor. Untuk menganalisis dosis yang diterima penduduk dilakukan dengan menggunakan program PC-CREAM. Perhitungan dilakukan untuk satu dan dua PLTN di calon tapak PLTN. Hasil yang diperoleh adalah sebaran radionuklida terbesar untuk satu PLTN pada jarak 1 km dan kearah zona 9 (191,25o dan untuk dua PLTN pada jarak 1 km dan kearah zona 10 (213,75o. Radionuklida yang sampai ke penduduk melalui dua alur yaitu alur makanan dan hirupan. Untuk alur makanan berasal dari radionuklida I-131, dan terbesar melalui alur produk susu sebesar 53,40 % untuk satu maupun dua PLTN . Untuk alur hirupan ranionuklida pemberi kontribusi paparan terbesar berasal dari Kr-85m sebesar 53,80 %. Dosis total terbesar yang diterima penduduk terdapat pada jarak 1 Km untuk bayi yaitu sebesar 4,10 μSi dan 11,26 μSi untuk satu dan dua PLTN. Hasil ini sangat kecil dibandingkan dengan batas dosis yang diijinkan oleh badan pengawas (BAPETEN untuk penduduk yaitu sebesar 1 mSi. Kata Kunci : Reaktor daya, komputer code, radionuklida, alur makanan, hirupan   Analysis for radionuclide dispersion for the Atomic Energy Agency (AEC 3568 MWth Power Reactor, equal to the 1000 MWe at normal condition has been done. Analysis was done for two piles that is separated by 500 m distance and angle of 90o one to other. Initial pace in doing the analysis is to determine reactors source term using ORIGEN2 and EMERALD NORMAL

  4. Analysis of radionuclide dispersion at normal condition for AEC 1000 MW reactor power

    International Nuclear Information System (INIS)

    Sri Kuntjoro

    2010-01-01

    Analysis for radionuclide dispersion for the Atomic Energy Agency (AEC) 3,568 MWth Power Reactor, equal to the 1,000 MWe at normal condition has been done. Analysis was done for two piles that is separated by 500 m distance and angle of 90° one to other. Initial pace in doing the analysis is to determine reactors source term using ORIGEN2 and EMERALD NORMAL. computer code program. ORIGEN2 applied to determine radionuclide inventory emerged in the reactor. Hereinafter, by using Emerald Normal Computer code is calculated source term reaching the reactor stack. To analyze dose received by population is done by using PC-CREAM computer code. Calculation done for one and two PLTN attached in site candidate of plants. The result showed is that the highest radionuclide release for one PLTN is at 1 km distance and to 9 th zone toward ( 19.25° ) and for two PLTN is at 1 km distance and to 10 th zone toward (21.75° ). Radionuclide which up to population through two pathways that are foodstuff and inhalation. To foodstuff comes from radionuclide I 131 , and the biggest passed from milk product with 53.40 % for one and also two PLTN For inhalation pathway the highest radionuclide contribution come from Kr 85m is about 53.80 %. The highest total dose received by population is at 1 Km distance received by baby that is 4.10 µSi and 11.26 µSi for one and two PLTN respectively. Those result are very small compared to the maximum permission dose to population issued by regulatory body that is equal to 1 mSi. (author)

  5. Development and analysis of a twelfth degree and order gravity model for Mars

    Science.gov (United States)

    Christensen, E. J.; Balmino, G.

    1979-01-01

    Satellite geodesy techniques previously applied to artificial earth satellites have been extended to obtain a high-resolution gravity field for Mars. Two-way Doppler data collected by 10 Deep Space Network (DSN) stations during Mariner 9 and Viking 1 and 2 missions have been processed to obtain a twelfth degree and order spherical harmonic model for the martian gravitational potential. The quality of this model was evaluated by examining the rms residuals within the fit and the ability of the model to predict the spacecraft state beyond the fit. Both indicators show that more data and higher degree and order harmonics will be required to further refine our knowledge of the martian gravity field. The model presented shows much promise, since it resolves local gravity features which correlate highly with the martian topography. An isostatic analysis based on this model, as well as an error analysis, shows rather complete compensation on a global (long wavelength) scale. Though further model refinements are necessary to be certain, local (short wavelength) features such as the shield volcanos in Tharsis appear to be uncompensated. These are interpreted to place some bounds on the internal structure of Mars.

  6. Twelfth annual meeting of the International Working Group on Fast Reactors. Summary report. Part I

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1979-05-01

    The Twelfth Annual Meeting of the IWGFR was held in accordance with the recommendation of the previous AGM,in Vienna from 27 to 30 March 1979. The meeting was attended by the Member States of the group: France, the Federal Republic of Germany, Italy, Japan, the United Kingdom, and the USA, as well as by representatives from CEC, IAEA and OECD and observer from the USSR. This document includes: review of the IWGFR Activities for the period since the Eleventh Annual Meeting of the Group; preliminary programme of international conference on breeder reactors as a world energy resource and the breeder fuel cycle; list of meetings on atomic energy which may be of interest to the IWGFR Members; IWGFR criteria for supporting some of the international conferences; list of proposed topics for the IWGFR Specialists' Meetings; list of topics for review articles on LMFBR recommended for publication by the IAEA; list of meetings sponsored by the IWGFR; a list of members of the International Working Group on Fast Reactors.

  7. Minutes of the Twelfth LWR pressure vessel surveillance dosimtery improvement program meeting

    International Nuclear Information System (INIS)

    1989-01-01

    The 1983 Twelfth Light Water Reactor Pressure Vessel Surveillance Dosimetry Improvement Program (LWR-PV-SDIP) Meeting, which was held October 24-28, 1983. Sections 1 through 14 of this report provide documentation of agreements, commitments, and reports that are subject to the approval and concurrence of the participating laboratories and supporting agencies and organizations. Attachment No. 1 provides information on the preparation of a number of NUREG publications that will document the results of various aspects of the LWR-PV-SDIP. For each NUREG publication, a tentative ''Table of Contents'' is provided in addition to suggested interlaboratory writing assignments and camera-ready copy contribution due dates, as appropriate. Attachment No. 2 provides information on planning for the Fifth ASTM-EURATOM Symposium. Attachment No. 3 provides information on an ASTM press release about an MPC-6 meeting and dpa and E > 1 MeV exposure parameters. Attachments No. 4 and 5 provide copies of two LWR-PV-SDIP related papers presented at the Eleventh WRSR Information Meeting, October 24-28, 1983

  8. Hebrew and Latin astrology in the twelfth century: the example of the location of pain.

    Science.gov (United States)

    Burnett, Charles

    2010-06-01

    The formative period of Latin and Hebrew astrology occurred virtually simultaneously in both cultures. In the second quarter of the twelfth century the terminology of the subject was established and the textbooks which became authoritative were written. The responsibility for this lay almost entirely with two scholars: John of Seville for the Latins, and Abraham ibn Ezra for the Jews. It is unlikely to have been by coincidence that the same developments in astrology occurred in these two cultures. John of Seville and Abraham ibn Ezra were both brought up within the Islamic culture of Spain, and their astrology was Arabic astrology. Moreover, some scholars have thought that John's origins were Jewish, while Ibn Ezra is known to have collaborated with Latin scholars (whose names are not recorded). It cannot be a coincidence that they forged the science of astrology for their respect co-religionists at almost the same time. Yet, very little research has been done on the possible relations between the two scholars. The purpose of this paper is to begin to explore this relationship, and to illustrate it in particular by their shared doctrine concern the location of pain.

  9. Twelfth annual meeting of the International Working Group on Fast Reactors. Summary report. Part I

    International Nuclear Information System (INIS)

    1979-05-01

    The Twelfth Annual Meeting of the IWGFR was held in accordance with the recommendation of the previous AGM,in Vienna from 27 to 30 March 1979. The meeting was attended by the Member States of the group: France, the Federal Republic of Germany, Italy, Japan, the United Kingdom, and the USA, as well as by representatives from CEC, IAEA and OECD and observer from the USSR. This document includes: review of the IWGFR Activities for the period since the Eleventh Annual Meeting of the Group; preliminary programme of international conference on breeder reactors as a world energy resource and the breeder fuel cycle; list of meetings on atomic energy which may be of interest to the IWGFR Members; IWGFR criteria for supporting some of the international conferences; list of proposed topics for the IWGFR Specialists' Meetings; list of topics for review articles on LMFBR recommended for publication by the IAEA; list of meetings sponsored by the IWGFR; a list of members of the International Working Group on Fast Reactors

  10. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  11. Noncondensable hydrogen sulfide incineration with brine scrubbing air emissions control system

    International Nuclear Information System (INIS)

    Goddard, W.B.; Goddard, C.B.; McClain, D.W.

    1990-01-01

    This paper reports on the technical and institutional feasibility of incinerating hydrogen sulfide (H2S) contained in geothermal noncondensable gases, and the use of geothermal brine for sulfur dioxide scrubbing and absorption as an Air Emissions Control System (AECS), for geothermal power plant, that have been documented through engineering analysis in the Phase I grant study funded through the California Department of Health Services (DOHS), Hazardous Materials Reduction Grant Program and hosted by California Energy Company (CECI). Grant funding for Phase II now has been approved to proceed with the project through the pilot plant design phase. This innovative AECS does not necessitate the use of hazardous materials or produce hazardous wastes. Cost savings were documented compared to injection pump operation or conventional AECS without the use of hazardous materials. The phase II project is to design, improve, research and develop a source reduction demonstration pilot plant geothermal noncondensable H2S incineration AECS

  12. Feasibility study of the correlation of lifetime health and mortality experience of AEC and AEC Contractor employees with occupational radiation exposure. Progress report No. 3, June 1, 1966-May 31, 1967

    Energy Technology Data Exchange (ETDEWEB)

    Mancuso, T.F.; Sanders, B.S.; Brodsky, A.

    1967-01-01

    The objective of this 5-year project is to assess the feasibility of using personnel, employment, medical, and radiation records in establishing the relationships between mortality patterns and levels of radiation exposure. The following AEC Contractor facilities were selected for the test runs: the three Oak Ridge facilities, Hanford, and several small feed materials plants. During this project year, the recording of personal data on Oak Ridge employees and feed materials centers will be intensified, other phases of the project will be continued, and the searching for deaths through the Social Security Administration will begin. (PCS)

  13. Energy and climate policy in China's twelfth five-year plan: A paradigm shift

    International Nuclear Information System (INIS)

    Li Jun; Wang Xin

    2012-01-01

    The twelfth five-year plan (FYP) endorsed by the People's National Congress in March 2011 plays a crucial role in shaping China's development trajectory over the next decades , and especially for the fulfillment of the 40–45 carbon intensity reduction target by 2020. The plan will condition both the medium and long term perspectives of economic restructuring, rebalance between the inclusive economic growth and environmental objectives, which are compounded by multiple constraints faced by China such as aging population, natural resources depletion, energy supply security and environmental deterioration. This article investigates the major energy and climate targets and actions specified in the 12th FYP to gain insights into the nature and magnitude of challenges and difficulties with regard to the medium and long run economic and environmental policies. It points out that China should articulate sectoral policies with the global climate mitigation targets to avoid long term carbon lock-in. Based on an in-depth analysis of the objectives in the plan, it is argued that the implementation should include mainstreaming developments of appropriate instruments to support cost-effective energy efficiency improvements and carbon intensity reduction in the next five years. - Highlights: ► We investigate the major energy and climate targets and actions specified in the Chinese 12th FYP. ► It points out FYP's implications for energy policy and global climate stabilisation. ► Challenges and difficulties with regard to the medium and long run climate strategies. ► Shift from investment and export-led to consumption led sustainable and inclusive growth model.

  14. Christianisation and the afterlife of pagan open-air cult sites

    NARCIS (Netherlands)

    Groenewoudt, B.J.; Beek, van Roy; Groothedde, Michel

    2016-01-01

    In this article we try to explain why some pagan open-air cult sites were used until the twelfth to thirteenth centuries or even later, long after the introduction of Christianity (sixth to eighth centuries) in what are now the Netherlands. To reconstruct the Christianization process we link Milis’

  15. Sexual dimorphic function of IL-17 in salivary gland dysfunction of the C57BL/6.NOD-Aec1Aec2 model of Sjögren's syndrome.

    Science.gov (United States)

    Voigt, Alexandria; Esfandiary, Lida; Wanchoo, Arun; Glenton, Patricia; Donate, Amy; Craft, William F; Craft, Serena L M; Nguyen, Cuong Q

    2016-12-13

    Interleukin (IL)-17 is one of the critical inflammatory cytokines that plays a direct role in development of Sjögren's syndrome (SjS), a systemic autoimmune disease characterized by a progressive chronic attack against the exocrine glands. The expression levels of IL-17 are correlated with a number of essential clinical parameters such as focus score and disease duration in human patients. Significantly immunological differences of Th17 cells were detected at the onset of clinical disease in female SjS mice compared to males. To further define the role of IL-17 in SjS and elucidate its involvement in the sexual dimorphism, we examined the systemic effect of IL-17 by genetically ablating Il-17 in the C57BL/6.NOD-Aec1Aec2, spontaneous SjS murine model. The results indicate that IL-17 is a potent inflammatory molecule in the induction of chemoattractants, cytokines, and glandular apoptosis in males and females. Elimination of IL-17 reduced sialadenitis more drastically in females than males. IL-17 is highly involved in modulating Th2 cytokines and altering autoantibody profiles which has a greater impact on changing plasma cells and germinal center B cell populations in females than males. The result supports a much more important role for IL-17 and demonstrates the sexual dimorphic function of IL-17 in SjS.

  16. Family Ownership and the Entrenchment Effect on Intellectual Capital Utilization: A Study of High-Technology Companies in Indonesia Dealing with the ASEAN Economic Community (AEC

    Directory of Open Access Journals (Sweden)

    Bima Cinintya Pratama

    2017-08-01

    Full Text Available At the end of 2015, the Association of Southeast Asian Nations (ASEAN brought into being the ASEAN Economic Community (AEC. Due to the AEC, the firms in ASEAN should utilize their resources more effectively and efficiently, so that the firms can survive and grow despite strong competition in the AEC. Indonesia, as the country with the largest economy in the region, needs to address this issue so that companies in Indonesia can face the challenges resulting from the AEC. This study aimed to examine the positive relationship between the intellectual capital (IC and the financial performance of high-technology (high-tech companies that are listed on the Indonesia Stock Exchange, and also to examine whether the entrenchment effect of family ownership exists. This study was conducted from 2008 to 2014. The final sample used in this study consisted of 31 companies with a total of 144 observations. This study used a panel data regression model analysis. The results showed that, for a company, IC has a positive impact on financial performance. This result indicated that the efficient and effective use of their IC will help the firms to achieve higher financial performance, and will be useful for dealing with the AEC. There was no evidence that the entrenchment effect exists in the family ownership of high-tech companies in Indonesia and hampers the utilization of IC.

  17. Family Ownership and the Entrenchment Effect on Intellectual Capital Utilization: A Study of High-Technology Companies in Indonesia Dealing with the ASEAN Economic Community (AEC

    Directory of Open Access Journals (Sweden)

    Bima Cinintya Pratama

    2017-07-01

    Full Text Available At the end of 2015, the Association of Southeast Asian Nations (ASEAN brought into being the ASEAN Economic Community (AEC. Due to the AEC, the firms in ASEAN should utilize their resources more effectively and efficiently, so that the firms can survive and grow despite strong competition in the AEC. Indonesia, as the country with the largest economy in the region, needs to address this issue so that companies in Indonesia can face the challenges resulting from the AEC. This study aimed to examine the positive relationship between the intellectual capital (IC and the financial performance of high-technology (high-tech companies that are listed on the Indonesia Stock Exchange, and also to examine whether the entrenchment effect of family ownership exists. This study was conducted from 2008 to 2014. The final sample used in this study consisted of 31 companies with a total of 144 observations. This study used a panel data regression model analysis. The results showed that, for a company, IC has a positive impact on financial performance. This result indicated that the efficient and effective use of their IC will help the firms to achieve higher financial performance, and will be useful for dealing with the AEC. There was no evidence that the entrenchment effect exists in the family ownership of high-tech companies in Indonesia and hampers the utilization of IC.

  18. A report of the overall working group of the AEC Committee on Development of Advanced Power Reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The AEC Committee on Development of Advanced Power Reactors was set up in April, 1978, following on the previous AEC Special Committee on Development of Advanced Power Reactors, in order to study on the complementary power reactors between current LWRs and future FBRs. The subjects of study by the overall working group are the status of advanced power reactors in views of the nuclear fuel cycle, the impacts on industries, the selection of reactor types under present international circumstances, and the evaluation of advanced power reactors in their technology and economy. The following matters are described: evaluations in view of the nuclear fuel cycle, i.e. the features of the ATR of Japan and CANDU reactors of Canada; international problems concerning nuclear nonproliferation and securing of uranium; problems in the diversification of power reactor types concerning the expenditure and technology; problems of technology in the ATR of Japan, CANDU reactors of Canada and Pu utilization for LWRs; and the economy of D 2 O power reactors, i.e. the ATR of Japan and CANDU reactors of Canada. (J.P.N.)

  19. Case report: unusual dental morphology in a child with ankyloblepharon-ectodermal defects-cleft lip/palate (AEC) syndrome.

    LENUS (Irish Health Repository)

    Fitzgerald, K

    2012-02-01

    BACKGROUND: Anomalies of dental anatomy are common in the ectodermal dysplasia syndromes. These anomalies, when found in combination with dental caries, can pose a restorative challenge for the paediatric dentist. Modification of traditional techniques and approaches may help the practitioner provide a successful treatment outcome. CASE REPORT: A 3 years and 11 months old girl with a diagnosis of ankyloblepharon-ectodermal dysplasiacleft lip\\/palate (AEC) syndrome was referred for treatment to a specialist paediatric dental service. Her abnormal dental anatomy, hypodontia and dental caries formed a triad of challenges for the team. Under general anaesthesia, her dentition was restored using a combination of restorative approaches and techniques, including the placement of both composite resin and preformed metal crown restorations. FOLLOW-UP: At 18-month followup, the family had successfully implemented good home care and dietary practices, and the local dental service had instituted a preventive programme consisting of regular examination, advice and fluoride varnish placement. The restorations remained intact and no further caries was detected. At 24-month follow-up, the first permanent molars were partially erupted, and displayed unusually deep fissures. There was also a degree of ectopic eruption of the first permanent molars, and possibly of one of the maxillary permanent incisors. CONCLUSION: Dental care for children with AEC syndrome is optimised by early intervention, good home care and regular professional review. Dental care providers should be aware of the possibility of complex dental anatomy, and bear this in mind should it become necessary to formulate a restorative treatment plan.

  20. SU-E-I-48: The Behavior of AEC in Scan Regions Outside the Localizer Radiograph FOV: An In Phantom Study of CT Systems From Four Vendors

    Energy Technology Data Exchange (ETDEWEB)

    Supanich, M [Rush University Medical Center, Chicago, IL (United States); Bevins, N [Henry Ford Health System, Detroit, MI (United States)

    2014-06-01

    Purpose: This review of scanners from 4 major manufacturers examines the clinical impact of performing CT scans that extend into areas of the body that were not acquired in the CT localizer radiograph. Methods: Anthropomorphic chest and abdomen phantoms were positioned together on the tables of CT scanners from 4 different vendors. All of the scanners offered an Automatic Exposure Control (AEC) option with both lateral and axial tube current modulation. A localizer radiograph was taken covering the entire extent of both phantoms and then the scanner's Chest-Abdomen-Pelvis (CAP) study was performed with the clinical AEC settings employed and the scan and reconstruction range extending from the superior portion of the chest phantom through the inferior portion of the abdomen phantom. A new study was then initiated with a localizer radiograph extending the length of the chest phantom (not covering the abdomen phantom). The same CAP protocol and AEC settings were then used to scan and reconstruct the entire length of both phantoms. Scan parameters at specific locations in the abdomen phantom from both studies were investigated using the information contained in the DICOM metadata of the reconstructed images. Results: The AEC systems on all scanners utilized different tube current settings in the abdomen phantom for the scan completed without the full localizer radiograph. The AEC system behavior was also scanner dependent with the default manual tube current, the maximum tube current and the tube current at the last known position observed as outcomes. Conclusion: The behavior of the AEC systems of CT scanners in regions not covered by the localizer radiograph is vendor dependent. To ensure optimal image quality and radiation exposure it is important to include the entire planned scan region in the localizer radiograph.

  1. SU-E-I-48: The Behavior of AEC in Scan Regions Outside the Localizer Radiograph FOV: An In Phantom Study of CT Systems From Four Vendors

    International Nuclear Information System (INIS)

    Supanich, M; Bevins, N

    2014-01-01

    Purpose: This review of scanners from 4 major manufacturers examines the clinical impact of performing CT scans that extend into areas of the body that were not acquired in the CT localizer radiograph. Methods: Anthropomorphic chest and abdomen phantoms were positioned together on the tables of CT scanners from 4 different vendors. All of the scanners offered an Automatic Exposure Control (AEC) option with both lateral and axial tube current modulation. A localizer radiograph was taken covering the entire extent of both phantoms and then the scanner's Chest-Abdomen-Pelvis (CAP) study was performed with the clinical AEC settings employed and the scan and reconstruction range extending from the superior portion of the chest phantom through the inferior portion of the abdomen phantom. A new study was then initiated with a localizer radiograph extending the length of the chest phantom (not covering the abdomen phantom). The same CAP protocol and AEC settings were then used to scan and reconstruct the entire length of both phantoms. Scan parameters at specific locations in the abdomen phantom from both studies were investigated using the information contained in the DICOM metadata of the reconstructed images. Results: The AEC systems on all scanners utilized different tube current settings in the abdomen phantom for the scan completed without the full localizer radiograph. The AEC system behavior was also scanner dependent with the default manual tube current, the maximum tube current and the tube current at the last known position observed as outcomes. Conclusion: The behavior of the AEC systems of CT scanners in regions not covered by the localizer radiograph is vendor dependent. To ensure optimal image quality and radiation exposure it is important to include the entire planned scan region in the localizer radiograph

  2. Formerly utilized MED/AEC sites remedial action program. Radiological survey of Universal Cyclopes, Inc., Titusville, Plant (formerly Vulcan Crucible Steel Company, Aliquippa, Pennsylvania, May 2-8, 1978)

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Mundis, R.L.; Mayes, C.B.

    1982-05-01

    A radiological survey was conducted at the Universal Cyclops, Inc. Titusville Plant (formerly Vulcan Crucible Steel Company), in Aliquippa, Pennsylvania, to determine the location and quantities of any radioactive materials remaining on the site as a result of MED/AEC activities in the late 1940s. This facility was used for rolling uranium billets during the MED/AEC era. The survey included measurements of alpha and beta-gamma contamination, both fixed and removable; beta-gamma exposure readings at contact and at 1 m (3 ft) above the floor or ground level; and measurements of the concentrations of radon daughters in air and concentrations of 137 Cs, the 232 Th decay chain, the 226 Ra decay chain, and uranium in the soil on the site. Fourteen spots of contamination exceeded the allowable limits for natural uranium. Under current use conditions, the potential for radiation exposure of occupants of the building from these sources of contamination is remote. Concentrations of radon daughters were below the 0.01 WL limit. Calculated radon concentrations based on the radon-daughter determinations ranged from 0.11 to 0.27 pCi/l. The concentration guide for 222 Rn in uncontrolled areas is 3 pCi/l. Analysis of soil samples from the site indicated elevated concentrations of uranium (15.1 +- 0.7 to 109.0 +- 5.5 pCi/g) at one sampling location near the building. There currently are no regulatory limits for uranium concentration in soil, but, a proposed guide value is pCi/g. After evaluation of results of the survey, it was concluded that although some areas of the Universal Cyclops facility are contaminated, these areas do not pose a significant risk to the present occupants of the building. Nonetheless, in a few cases the contamination does exceed accepted guidelines. Remedial measures are indicated to bring the contaminated areas within the guidelines

  3. A brief history of the air cleaning conferences

    International Nuclear Information System (INIS)

    First, M.W.

    1995-01-01

    I have been asked to prepare a history of the air cleaning conferences. Undertaking such a task is, of course, a wonderful opportunity for reminiscences and a chance to retell old war stories. I must admit that it has taken much longer than I anticipated because I found myself so completely engrossed rereading the old records that time seemed to stop, although the hours passed. But a history of the nuclear air cleaning conferences means more than a stroll down memory lane. The 23 recorded air cleaning conference proceedings reflect an important aspect of the history of major nuclear developments, both military and civilian, because engineered safety features designed to prevent dispersion of radioactive products to the environment have always been a necessity for progress in this field. For this reason, I hope the history of the nuclear air cleaning conferences will not only be enjoyable, but also have meaning for young people entering this field. The air cleaning conferences were an outgrowth of the operations of the U.S. Atomic Energy Commission's (AEC) Stack Gas Working Group established in 1948 to review air cleaning operations at AEC installations. AEC's Division of Engineering sponsored and funded air cleaning research and development at Harvard University's School of Public Health, beginning about the same time. In addition to research and development, the Harvard contract called for consulting and educational services. The latter provided the opportunity for meetings devoted to information on air cleaning that could be applied to ongoing and anticipated nuclear operations

  4. Toward a regional power plant siting method: AEC-Maryland regional siting factors study, FY 1974 progress report

    International Nuclear Information System (INIS)

    Yaffee, S.L.; Miller, C.A.

    1974-11-01

    The ''AEC-Maryland Regional Siting Factors Study'' examines the process of siting in a regional context. It is developing an analysis method to delineate candidate areas for siting of several power plant technology packages, including both fossil-fueled and nuclear options. Tools that are being used include simulation modeling, economic and demographic forecasting, spatial analysis, and computer graphics and numerical manipulation. The approach will describe the trade-offs incurred if a power plant is located in one candidate area rather than in another. In FY 1974, a suitability analysis method was developed which uses engineering and environmental parameters to define a level of environmental cost incurred if a segment of land is used to site a specific technology package. (U.S.)

  5. WIDM'12 : the proceedings of the twelfth ACM international workshop on Web information and data management, November 2, 2012, Maui, Hawaii, USA

    NARCIS (Netherlands)

    Fletcher, G.H.L.; Mitra, P.

    2012-01-01

    We give an overview of WIDM 2012, held in conjunction with CIKM2012 inMaui, Hawaii. WIDM 2012 is the twelfth in a series of international workshops on Web Information and Data Management held in conjunction with CIKM since 1998. The objective of the workshop is to bring together researchers and

  6. Engineering evaluation of a formerly utilized MED/AEC site. Site A and Plot M, Palos Forest Preserve, Palos Park, Illinois

    International Nuclear Information System (INIS)

    1979-09-01

    This engineering evaluation report (EER) addresses one of these MED/AEC sites known as Site A/Plot M, located in Palos Park, Illinois. The EER describes in technical detail a number of options for remedial action that could be taken with respect to the contamination at Site A/Plot M and presents estimates of the costs associated with these options. A companion document, Environmental Analysis Report on a Formerly Utilized MED/AEC Site, Site A and Plot M, Palos Forest Preserve, Palos Park, Illinois (ANL/ES-79), has also been prepared. It describes in detail the existing site environment and evaluates the environmental impacts of the various remedial options discussed in this report. This EER contributes to a better understanding of the mitigation or resolution of environmental problems posed by the subject MED/AEC site and serves as a basis for determining whether or not remedial actions are warranted. The knowledge derived from the evaluation of a number of remedial options should be helpful in the final disposition of other MED/AEC sites located elsewhere

  7. A brief introduction of the constructing work of national radiation monitoring system during the twelfth five-year

    International Nuclear Information System (INIS)

    Liu Hua; Zhao Yongkang; Pan Su; Zhang Jiali; Yang Bin

    2013-01-01

    Radiation monitoring is the technical groundwork of nuclear and radiation safety regulating. In order to overcome the challenges coming with the development of nuclear energy and technology in china, the program of constructing National Radiation Monitoring System (NRMS) was put forward in the twelfth five-year plan of nuclear safety and prevention of radiation pollution, and the view target in 2020. The implementation plan of the constructing of NRMS has been drew up by the Ministry of Environmental Protection in 2012, which including the construction of organization and human resource system, laws and standards system, quality assurance system, technical research and innovation system, and capability insurance system. A brief introduction of the implementation plan was given in the article, the achievements during the eleventh five-year were reviewed, the challenges and working points were analyzed. (authors)

  8. A brief history of the air cleaning conferences

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W.

    1995-02-01

    I have been asked to prepare a history of the air cleaning conferences. Undertaking such a task is, of course, a wonderful opportunity for reminiscences and a chance to retell old war stories. I must admit that it has taken much longer than I anticipated because I found myself so completely engrossed rereading the old records that time seemed to stop, although the hours passed. But a history of the nuclear air cleaning conferences means more than a stroll down memory lane. The 23 recorded air cleaning conference proceedings reflect an important aspect of the history of major nuclear developments, both military and civilian, because engineered safety features designed to prevent dispersion of radioactive products to the environment have always been a necessity for progress in this field. For this reason, I hope the history of the nuclear air cleaning conferences will not only be enjoyable, but also have meaning for young people entering this field. The air cleaning conferences were an outgrowth of the operations of the U.S. Atomic Energy Commission`s (AEC) Stack Gas Working Group established in 1948 to review air cleaning operations at AEC installations. AEC`s Division of Engineering sponsored and funded air cleaning research and development at Harvard University`s School of Public Health, beginning about the same time. In addition to research and development, the Harvard contract called for consulting and educational services. The latter provided the opportunity for meetings devoted to information on air cleaning that could be applied to ongoing and anticipated nuclear operations.

  9. Radiocesium concentrations of snakes from contaminated and non-contaminated habitats of the AEC Savannah River Plant

    International Nuclear Information System (INIS)

    Brisbin, I.L. Jr.; Staton, M.A.; Pinder, J.E. III.; Geiger, R.A.

    1974-01-01

    Concentration levels of 134 Cs and 137 Cs were determined for 117 snakes of 19 species collected on the AEC Savannah River Plant near Aiken, South Carolina. Snakes collected from the vicinity of a reactor effluent stream averaged 131.5 pCi radiocesium/g live weight, with a maximum of 1032.6 pCi/g, and represented the highest level of radiocesium concentration reported in the literature for any naturally-occurring wild population of vertebrate predators. These snakes had significantly higher concentrations of radiocesium than those collected in the vicinity of a reactor cooling reservoir which averaged 27.7 pCi/g live weight, with a maximum of 139.3 pCi/g. The radiocesium contents of snakes collected from uncontaminated habitats averaged 2.6 and 2.4 pCi/g live weight, respectively, and did not differ significantly from background radiation levels. Radiocesium concentrations approximated a log-normal frequency distribution, and no significant differences in frequency-distribution patterns could be demonstrated between collection areas. (U.S.)

  10. Historical nuclear materials balance report for the former AEC-owned Weldon Spring Chemical Plant, Weldon Spring, Missouri

    International Nuclear Information System (INIS)

    Harris, R.A.

    1986-07-01

    From June 1957 through December 1966, four types of nuclear material were processed in the AEC-owned Weldon Spring Chemical Plant. These materials were: (1) natural uranium, (2) depleted uranium, (3) slightly enriched uranium, and (4) natural thorium. The summary material balances for each material are shown in Table 1. In processing these materials, discards occurred to (a) the atmosphere through stacks, (b) area waterways through sewers, and (c) to raffinate pits still in existence at the site. These discards are summarized in Table 2. Natural uranium processing accounted for more than 97% of the nuclear materials throughput (Table 1). Total material balance closures for natural uranium, depleted uranium, slightly enriched uranium, and natural thorium were 99.94%, 100%, 99.27%, and 98.52%, respectively. Of the discards, summarized in Table 2, approximately 75% went to and remain in the existing raffinate pits. Discharges to stacks and sewers account for the remaining discards. As far as can be determined, it appears all plant processes operated efficiently and all materials were well accounted for with only minimal variances

  11. 10 kVp rule – An anthropomorphic pelvis phantom imaging study using a CR system: Impact on image quality and effective dose using AEC and manual mode

    International Nuclear Information System (INIS)

    Lança, Luís; Franco, Loris; Ahmed, Abdulfatah; Harderwijk, Marloes; Marti, Chloe; Nasir, Sadeeda; Ndlovu, Junior; Oliveira, Miguel; Santiago, Ana Rita; Hogg, Peter

    2014-01-01

    Purpose: This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials: To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results: A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion: Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed

  12. Image quality and dose analysis for a PA chest X-ray: Comparison between AEC mode acquisition and manual mode using the 10 kVp ‘rule’

    International Nuclear Information System (INIS)

    Reis, Cláudia; Gonçalves, João; Klompmaker, Corrie; Bárbara, Ana Rita; Bloor, Chloe; Hegarty, Ryan; Lagrange, Tania; Temming, Noëlle; Sønnesyn, Mathilde; Røkeness, Henriette; Yamasathien, Amandine; Hogg, Peter

    2014-01-01

    Purpose: To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method: 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results: Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion: In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality

  13. [AIDS in the city: a TV series fascinates Ivoirians. After the twelfth episode].

    Science.gov (United States)

    Morand, C

    Every Tuesday night after the news, the entire Ivory Coast is riveted in front of the television to follow the 12-episode series "AIDS in the City" on the national channel. The citizens are passionate about the saga of a very ordinary family, whose routine is going to change after the father learns about his HIV seropositivity after a bet with his friends. The series has won the prize for the best work of fiction in the TV category at the last Fespaco and has already attracted TV stations in Burkina Faso, Guinea, and Senegal. The only condition asked of the African television stations in order to get a copy of the series is to collaborate with their national AIDS control committee for drama. After the airing of each episode, some shows broadcast over the radio network Allocodrome or some drama conducted in quarters of Abidjan show at what point Ivorians are concerned about the struggles of the father with his wife, his mistresses, his boss, or his neighbors. One show even is calling on the public to imagine the rest of the story because 16 new episodes will be shot next July-August. An actress in the TV show says that the persons involved in the show are going to remember the suggestions by viewers as the episodes are being worked out. A USAID-supported nongovernmental organization is leading the campaign against AIDS through promotion of the condom brand, Prudence. It provided the funds for the series under the condition that advertising spots praising the merits of the condom Prudence occur before and after each episode. All persons working on the series worked at a reduced salary so as to contribute to the fight against AIDS.

  14. Fiscal transfers based on inputs or outcomes? Lessons from the Twelfth and Thirteenth Finance Commission in India.

    Science.gov (United States)

    Fan, Victoria Y; Iyer, Smriti; Kapur, Avani; Mahbub, Rifaiyat; Mukherjee, Anit

    2018-01-01

    There is limited empirical evidence about the efficacy of fiscal transfers for a specific purpose, including for health which represents an important source of funds for the delivery of public services especially in large populous countries such as India. To examine two distinct methodologies for allocating specific-purpose centre-to-state transfers, one using an input-based formula focused on equity and the other using an outcome-based formula focused on performance. We examine the Twelfth Finance Commission (12FC)'s use of Equalization Grants for Health (EGH) as an input-based formula and the Thirteenth Finance Commission (13FC)'s use of Incentive Grants for Health (IGH) as an outcome-based formula. We simulate and replicate the allocation of these two transfer methodologies and examine the consequences of these fiscal transfer mechanisms. The EGH placed conditions for releasing funds, but states varied in their ability to meet those conditions, and hence their allocations varied, eg, Madhya Pradesh received 100% and Odisha 67% of its expected allocation. Due to the design of the IGH formula, IGH allocations were unequally distributed and highly concentrated in 4 states (Manipur, Sikkim, Tamil Nadu, Nagaland), which received over half the national IGH allocation. The EGH had limited impact in achieving equalization, whereas the IGH rewards were concentrated in states which were already doing better. Greater transparency and accountability of centre-to-state allocations and specifically their methodologies are needed to ensure that allocation objectives are aligned to performance. © 2017 The Authors. The International Journal of Health Planning and Management published by John Wiley & Sons Ltd.

  15. Report on the results of the twelfth medical examination of atomic bomb survivors residing in North America

    International Nuclear Information System (INIS)

    Yamamoto, Yasuji; Ohama, Koso; Fujiwara, Saeko

    2000-01-01

    The twelfth medical examination of atomic bomb survivors residing in North America, was conducted in San Francisco and Seattle from May 20 through June 2 1999, and in Los Angeles and Hawaii from June 9 through 23 1999, The examination included an interview, measurement of height, weight, and blood pressure, an ECG, urine and stool tests, blood tests, a physical examination, examination of the breast, thyroid, and rectum by a surgeon, and screening for uterine cancer and a gynecological interview and examination by an obstetrician and gynecologist. The total confirmed number of A-bomb survivors residing in North America as of the end of June 1999 was 1076. Of the 1062 survivors that remained after excluding the 14 subjects whose survey was incomplete, 279 males and 654 females had been exposed in Hiroshima, and 10 males and 119 females in Nagasaki. The peak age at the time of exposure in both sexes was 15-19 years, followed by 10-14 years. The number of survivors exposed <2000 m from the hypocenter was 236, accounting for 21.9% of the total. The confirmed number of survivors exposed in utero was 26. The survivors' age (mean ±S.D.) was: 69.0±8.69 years; males, 68.4±80.5 years; females, 69.2±8.91 years. A total of 414 survivors were examined (male 129; female 285; mean age 68.0 years). Approximately 80% of the examinees had experienced at least one general symptom. Many still complain of symptoms that suggest possible posttraumatic stress disorder as a result of exposure to the A-bomb. It will be necessary to consider providing mental health care by psychiatrists beginning with the next examination. The prevalence of life-style diseases has been gradually increased with age. A previous history of cancer was found in 9.2% of the examinees. The most prevalent was of breast cancer, followed by malignant tumors of the colon, rectum, uterus, brain, stomach, and thyroid. The need for cancer screening and promotion of life-style education was keenly felt. (K.H.)

  16. Report on the results of the twelfth medical examination of atomic bomb survivors residing in North America

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Yasuji [Hiroshima Prefectural Medical Association (Japan); Ohama, Koso; Fujiwara, Saeko (and others)

    2000-06-01

    The twelfth medical examination of atomic bomb survivors residing in North America, was conducted in San Francisco and Seattle from May 20 through June 2 1999, and in Los Angeles and Hawaii from June 9 through 23 1999, The examination included an interview, measurement of height, weight, and blood pressure, an ECG, urine and stool tests, blood tests, a physical examination, examination of the breast, thyroid, and rectum by a surgeon, and screening for uterine cancer and a gynecological interview and examination by an obstetrician and gynecologist. The total confirmed number of A-bomb survivors residing in North America as of the end of June 1999 was 1076. Of the 1062 survivors that remained after excluding the 14 subjects whose survey was incomplete, 279 males and 654 females had been exposed in Hiroshima, and 10 males and 119 females in Nagasaki. The peak age at the time of exposure in both sexes was 15-19 years, followed by 10-14 years. The number of survivors exposed <2000 m from the hypocenter was 236, accounting for 21.9% of the total. The confirmed number of survivors exposed in utero was 26. The survivors' age (mean {+-}S.D.) was: 69.0{+-}8.69 years; males, 68.4{+-}80.5 years; females, 69.2{+-}8.91 years. A total of 414 survivors were examined (male 129; female 285; mean age 68.0 years). Approximately 80% of the examinees had experienced at least one general symptom. Many still complain of symptoms that suggest possible posttraumatic stress disorder as a result of exposure to the A-bomb. It will be necessary to consider providing mental health care by psychiatrists beginning with the next examination. The prevalence of life-style diseases has been gradually increased with age. A previous history of cancer was found in 9.2% of the examinees. The most prevalent was of breast cancer, followed by malignant tumors of the colon, rectum, uterus, brain, stomach, and thyroid. The need for cancer screening and promotion of life-style education was keenly felt. (K.H.)

  17. Organisation of biological research carried out in the United States by the A.E.C. or under her contract (1960)

    International Nuclear Information System (INIS)

    Pellerin, J.

    1960-01-01

    This report is based on information gathered in the course of a trip to the United States, in November and December 1958 which consisted chiefly of visits to the main biological and medical research laboratories and discussions with the heads of these establishments. A description is given of the general organisation of the Atomic Energy Commission's Division of Biology and Medicine, and of the distribution of responsibility for radiation protection work and for biological, medical and agricultural research amongst the various Services attached to it; this is followed by a more detailed account of the activities carried on in this field at the great national laboratories. Finally, the systems of collaboration set up with external research organisations in the form of research contracts are examined, together with the substantial help provided by the A.E.C. for biological, medical and agricultural research in general, owing to a systematic policy of subsidising the distribution of radioisotopes for this purpose. (author) [fr

  18. SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order

    International Nuclear Information System (INIS)

    Winslow, J; Hurwitz, L; Christianson, O; Samei, E

    2014-01-01

    Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HD scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose

  19. [Study of CT Automatic Exposure Control System (CT-AEC) Optimization in CT Angiography of Lower Extremity Artery by Considering Contrast-to-Noise Ratio].

    Science.gov (United States)

    Inada, Satoshi; Masuda, Takanori; Maruyama, Naoya; Yamashita, Yukari; Sato, Tomoyasu; Imada, Naoyuki

    2016-01-01

    To evaluate the image quality and effect of radiation dose reduction by setting for computed tomography automatic exposure control system (CT-AEC) in computed tomographic angiography (CTA) of lower extremity artery. Two methods of setting were compared for CT-AEC [conventional and contrast-to-noise ratio (CNR) methods]. Conventional method was set noise index (NI): 14and tube current threshold: 10-750 mA. CNR method was set NI: 18, minimum tube current: (X+Y)/2 mA (X, Y: maximum X (Y)-axis tube current value of leg in NI: 14), and maximum tube current: 750 mA. The image quality was evaluated by CNR, and radiation dose reduction was evaluated by dose-length-product (DLP). In conventional method, mean CNRs for pelvis, femur, and leg were 19.9±4.8, 20.4±5.4, and 16.2±4.3, respectively. There was a significant difference between the CNRs of pelvis and leg (P<0.001), and between femur and leg (P<0.001). In CNR method, mean CNRs for pelvis, femur, and leg were 15.2±3.3, 15.3±3.2, and 15.3±3.1, respectively; no significant difference between pelvis, femur, and leg (P=0.973) in CNR method was observed. Mean DLPs were 1457±434 mGy⋅cm in conventional method, and 1049±434 mGy·cm in CNR method. There was a significant difference in the DLPs of conventional method and CNR method (P<0.001). CNR method gave equal CNRs for pelvis, femur, and leg, and was beneficial for radiation dose reduction in CTA of lower extremity artery.

  20. Formerly utilized MED/AEC sites remedial action program. Radiological survey of the West Stands, New Chemistry Lab and Annex, and Ricketts Laboratory, the University of Chicago, Chicago, Illinois, August 31-September 2, 1977

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Mayes, C.B.; Justus, A.L.

    1982-05-01

    A radiological survey was conducted at the former locations of the West Stands, the New Chemistry Lab and Annex, and Ricketts Laboratory at the University of Chicago, Chicago, Illinois. General radiochemistry and/or physics research for the MED/AEC program was performed at these sites during the 1940s. The buildings have since been razed. The survey was undertaken to determine the presence of any radionuclides remaining from the MED/AEC operations that could have been spilled or released from the former structures. Environmental soil samples (corings) were collected from the areas where the West Stands, New Chemistry Lab and Annex, and Ricketts Laboratory once stood. The soil corings were taken at what appeared to be undisturbed locations near the sites of the three former facilities. Analyses of the soil corings included determination of the concentrations of 137 Cs, the 232 Th decay chain, the 226 Ra decay chain, and uranium in the soil. The levels of uranium and the 226 Ra decay chain found in the samples indicated that no concentrations above natural background levels were present. Slightly elevated levels of 60 Co were found in soil taken from the top 5 cm of the ground at two sampling sites, but this activity was presumed to have been traceable to induced activity from contaminated stainless steel that had been stored in the area during operations not related to MED/AEC activities. No increased radiation dose attributable to exposure to residual radioactivity from MED/AEC activities is expected

  1. AEC authorizing legislation, fiscal year 1975. Part 3. Hearings before the Joint Committee on Atomic Energy, Congress of the United States, Ninety-Third Congress, Second Session on Physical Research and Regulatory, February 28, 1974

    International Nuclear Information System (INIS)

    1974-01-01

    This volume contains testimony on the proposed budget for the physical research program presented at public hearings of the Joint Committee on Atomic Energy on the proposed AEC authorizing legislation for fiscal year 1975. Atomic Energy Commission witnesses were Commissioner William O. Doub; Director of Regulation L. Manning Muntzing; Dr. Wolfgang K. H. Panofsky, Director, SLAC; Dr. John M. Teem, Assistant General Manager for Physical Research and Laboratory Coordination; and Dr. Robert R. Wilson, Director, NAL. Other witnesses included B. James Porter, Donald C. Gilbert, Hon. Sterling Cole, and Wyatt M. Rogers, Jr. Prepared statements, questions and answers, a letter from AEC Chairman Ray, and the report of the ad hoc panel on heavy-ion facilities are included. (U.S.)

  2. The Weight of Evidence Does Not Support the Listing of Styrene as “Reasonably Anticipated to be a Human Carcinogen” in NTP's Twelfth Report on Carcinogens

    Science.gov (United States)

    Rhomberg, Lorenz R.; Goodman, Julie E.; Prueitt, Robyn L.

    2013-01-01

    Styrene was listed as “reasonably anticipated to be a human carcinogen” in the twelfth edition of the National Toxicology Program's Report on Carcinogens based on what we contend are erroneous findings of limited evidence of carcinogenicity in humans, sufficient evidence of carcinogenicity in experimental animals, and supporting mechanistic data. The epidemiology studies show no consistent increased incidence of, or mortality from, any type of cancer. In animal studies, increased incidence rates of mostly benign tumors have been observed only in certain strains of one species (mice) and at one tissue site (lung). The lack of concordance of tumor incidence and tumor type among animals (even within the same species) and humans indicates that there has been no particular cancer consistently observed among all available studies. The only plausible mechanism for styrene-induced carcinogenesis—a non-genotoxic mode of action that is specific to the mouse lung—is not relevant to humans. As a whole, the evidence does not support the characterization of styrene as “reasonably anticipated to be a human carcinogen,” and styrene should not be listed in the Report on Carcinogens. PMID:23335843

  3. Formerly utilized MED/AEC sites remedial action program. Radiological survey of the former Watertown arsenal property, Site 34 and Site 41, Watertown, Massachusetts

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Justus, A.L.; Flynn, K.F.

    1983-10-01

    During the MED/AEC era, work involving radioactive materials was conducted at various sites within the arsenal complex. Building 34 housed a uranium machine shop, and a portion of Building 41 contained a foundry that was used for uranium work. Information provided by site personnel indicated that only depleted uranium was used in these buildings. Results of radiological analyses of contaminated material found at these sites indicated depleted uranium with uranium-236. Both buildings have been razed. The remnants still in place consist of the concrete floor slabs, access drives, and underground utility service trenches. This area is currently under the control of the Watertown Redevelopment Authority of Watertown, Massachusetts. During the period from June 25 through July 1, 1981, the Argonne National Laboratory (ANL), Occupational Health and Safety Division (OHS) Radiological Survey Group (RSG), conducted a radiological survey of Building Sites 34 and 41 at the direction of the US Department of Energy. Significant levels of contamination were found at 33 locations on the pad of Site 34 and in 5 out of 15 soild corings from the perimeter of the pad. No contamination was found on the pad of Site 41; however, two-thirds of this pad was covered with soil up to 4 ft thick. One of the 14 soil corings taken adjacent to the pad of Site 41 had elevated levels of uranium. Levels of contamination in excess of criteria, as identified in ANSI 13.12 and NRC Guidelines, were found at this site. The analyses of the samples from the sewer access points also revealed uranium and radium-226 anomalies. Therefore, according to NRC guidelines dated July 1982, it must be concluded that they are contaminated

  4. AEC controlled area safety program

    International Nuclear Information System (INIS)

    Hendricks, D.W.

    1969-01-01

    The detonation of underground nuclear explosives and the subsequent data recovery efforts require a comprehensive pre- and post-detonation safety program for workers within the controlled area. The general personnel monitoring and environmental surveillance program at the Nevada Test Site are presented. Some of the more unusual health-physics aspects involved in the operation of this program are also discussed. The application of experience gained at the Nevada Test Site is illustrated by description of the on-site operational and safety programs established for Project Gasbuggy. (author)

  5. AEC controlled area safety program

    Energy Technology Data Exchange (ETDEWEB)

    Hendricks, D W [Nevada Operations Office, Atomic Energy Commission, Las Vegas, NV (United States)

    1969-07-01

    The detonation of underground nuclear explosives and the subsequent data recovery efforts require a comprehensive pre- and post-detonation safety program for workers within the controlled area. The general personnel monitoring and environmental surveillance program at the Nevada Test Site are presented. Some of the more unusual health-physics aspects involved in the operation of this program are also discussed. The application of experience gained at the Nevada Test Site is illustrated by description of the on-site operational and safety programs established for Project Gasbuggy. (author)

  6. Index to AEC Information Booklets

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-01-01

    The U. S. Atomic Energy Commission publishes a series of information booklets for the general public. These booklets explain many aspects of nuclear science. Because these booklets cover such a variety of scientific fields, this index was prepared to help the reader find quickly those booklets that contain the information he needs.

  7. Air Research

    Science.gov (United States)

    EPA's air research provides the critical science to develop and implement outdoor air regulations under the Clean Air Act and puts new tools and information in the hands of air quality managers and regulators to protect the air we breathe.

  8. An Evaluation of Indonesian Capital Market Co-integration with ASEAN 4 to Enter the ASEAN Capital Market Integration in Accordance to ASEAN Economic Community (AEC 2020 Scheme: Should Indonesia Enter or Postpone?

    Directory of Open Access Journals (Sweden)

    Barli Suryanta

    2014-08-01

    Full Text Available Association of South East Asian Nations (ASEAN Economic Community (AEC 2020 has already been declared on 7 October 2003 by ASEAN Concord II in Bali, Indonesia. In general, AEC was designed to prepare ASEAN countries for ASEAN economic integration within the next 10-15 year. ASEAN Free Trade  Area (AFTA  had  actually  been  launched since 1992 though was not comprehensive enough and kept ASEAN only partially integrated. To overcome it, ASEAN proposed  inancial  integration  through  capital market  integration based on AEC commitment in order to reach comprehensive ASEAN economic integration. Indonesia is one of the  ASEAN  members  that  is  linked  by AEC  2020.  The  purpose  of  this paper is to evaluate Indonesian capital market co-integration in entering the ASEAN capital market integration compared to those of ASEAN 4. To examine the notion of the Indonesian capital  market  integration  within ASEAN  region, cointegration model  is  utilised  to  igure out co-integration between Indonesian stock market indices and ASEAN 4, i.e., Singapore, Malaysia, Philippines and Thailand. In addition, Vector Auto-regression (VAR model is also utilised to examine Indonesian market returns co-movement and dynamic link with ASEAN 4.  The  conclusions  of  this  research,  i.e.  co-integration  between  Indonesian  capital  market with  Singaporean,  Malaysian,  Philippines,  and  Thailand  does  not  exist;  there  is  neither co-movement  nor  strong  dynamic  link  between  Indonesian  capital  market  with  those  of Singaporean, Malaysian, Philippines, and Thailand. This paper also recommends Indonesia to postpone the integration of its capital market into the integrated ASEAN capital market. ";} // -->activate javascript

  9. Bacterial community structures in air conditioners installed in Japanese residential buildings.

    Science.gov (United States)

    Hatayama, Kouta; Oikawa, Yurika; Ito, Hiroyuki

    2018-01-01

    The bacterial community structures in four Japanese split-type air conditioners were analyzed using a next-generation sequencer. A variety of bacteria were detected in the air filter of an air conditioner installed on the first floor. In the evaporator of this air conditioner, bacteria belonging to the genus Methylobacterium, or the family of Sphingomonadaceae, were predominantly detected. On the other hand, the majority of bacteria detected in the air filters and evaporators of air conditioners installed on the fifth and twelfth floors belonged to the family Enterobacteriaceae. The source of bacteria belonging to the family Enterobacteriaceae may have been aerosols generated by toilet flushing in the buildings. Our results suggested the possibility that the bacterial contamination in the air conditioners was affected by the floor level on which they were installed. The air conditioner installed on the lower floor, near the ground, may have been contaminated by a variety of outdoor bacteria, whereas the air conditioners installed on floors more distant from the ground may have been less contaminated by outdoor bacteria. However, these suppositions may apply only to the specific split-type air conditioners that we analyzed, because our sample size was small.

  10. Shakespeare revisité, entre fidélité et parodie : de La Nuit des Rois à Shake de Dan Jemmett Shakespeare Revisited, Between Fidelity and Parody: From Twelfth Night to Shake by Dan Jemmett

    Directory of Open Access Journals (Sweden)

    Isabelle Schwartz-Gastine

    2009-11-01

    Full Text Available William Shakespeare himself was a master of re-writing older material as he abundantly used this technique, which was totally justified at the Renaissance, to compose his poems or plays, from various sources whether literary (prose or verse, historical, or any other—and sometimes most unusual—background.The play I am considering in this paper is a very recent re-writing in English by Dan Jemmett (Peter Brook’s son-in-law, but performed in Marie-Paul Remo’s French translation at the Vidy Theatre in Lausanne during the 2001 season. It is called Shake, with a modest sub-title « around Twelfth Night », but which is indeed at the heart of the topic.Through the exploration of three themes: symmetry (of situations, of twin binarities, love’s misunderstanding, and music, I will argue that this comedy, whose title is a mix between the name of the Bard and the etymological meaning of the verb “to shake” as far as traditions are concerned, is faithful to the spirit (rather than the letter of the Shakespearean original in a very healthy comic vein.It is not worth wondering if the spectators fully understood the meaning of this comedy in which the four actors change roles all the time: their frequent bursts of laughter clearly showed that they enjoyed the spirit of the comedy, whether they knew Twelfth Night or not.

  11. Evaluation of the impact of general phosphate fertilizers factories company on the surrounding environment by determining natural radionuclides and some trace elements in air particulates

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Al-Kharfan, K.; Al-Hamwi, A.; Al-Shamali, K.

    2004-01-01

    Natural radionuclides and some trace element levels in air particulates of the areas surrounding the phosphate fertilizers factory in Homs have been determined Mean total air particulates concentration ranged from 31 μg/m3 in Kerba Al-Teen in Autumn period. While trace element concentrations in air particulates were relatively high in air particulates collected from AECS center and other sites situated north east of the factory; about 1.7 ng/m3 in AECS site and 1.7 ng/m3 in Abel for uranium and cadmium, respectively. In addition, radioactivity analysis of air particulates has shown low levels of polonium 210 and lead 210; a value of 2 mBq/m3 in Kerba Al-Teen has not been exceeded. However, air particulate, natural radionuclides and the studied trace elements concentrations in the surrounding areas were within the natural levels. Therefore, air emissions from the factory containing radioactive materials and trace elements are relatively low. This is due to strict control procedures on transport and loading processes of phosphate in addition to the high efficiency of filters used for air emissions from the phosphate fertilizers factory during the study period (2002). (author)

  12. Evaluation of the impact of general phosphate fertilizers factories company on the surrounding environment by determining natural radionuclides and some trace elements in air particulates

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Al-Kharfan, K.; Al-Hamwi, A.; Al-Shmali, K.; Abdul Haleem, M.

    2003-12-01

    Natural radionuclides and some trace element levels in air particulates of the areas surrounding the phosphate fertilizers factory in Homs have been determined mean total air particulates concentration ranged from 31μg/m 3 in Kerba Al-Teen in autumn period. While trace element concentrations in air particulates were relatively high in air particulates collected from AECS center and other sites situated north east of the factory: about 1.7 ng/m 3 in AECS site and 1.7 ng/m 3 in Abel for uranium and cadmium, respectively. In addition, radioactivity analysis of air particulates have shown low levels of polonium 210 and lead 210, a value of 2 mBg/m 3 in Kerba Al-Teen has not been exceeded. However, air particulate, natural radionuclides and the studied trace elements concentrations in the surrounding areas were within the natural levels. Therefore, air emissions from the factory containing radioactive materials and trace elements are relatively low. This is due to strict control procedures on transport and loading processes of phosphate in addition to the high efficiency of filters used for air emissions from the phosphate fertilizers factory during the study period (2002).(author)

  13. Air Pollution

    Science.gov (United States)

    Air pollution is a mixture of solid particles and gases in the air. Car emissions, chemicals from factories, ... Ozone, a gas, is a major part of air pollution in cities. When ozone forms air pollution, it's ...

  14. Nuclides and isotopes. Twelfth edition

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This explanatory booklet was designed to be used with the Chart of the Nuclides. It contains a brief history of the atomic theory of matter: ancient speculations, periodic properties of elements (Mendeleev table), radioactivity, early models of atomic structure, the Bohr atom, quantum numbers, nature of isotopes, artificial radioactivity, and neutron fission. Information on the pre-Fermi (natural) nuclear reactor at Oklo and the search for superheavy elements is given. The booklet also discusses information presented on the Chart and its coding: stable nuclides, metastable states, data display and color, isotopic abundances, neutron cross sections, spins and parities, fission yields, half-life variability, radioisotope power and production data, radioactive decay chains, and elements without names. The Periodic Table of the Elements is appended. 3 figures, 3 tables

  15. Air Abrasion

    Science.gov (United States)

    ... Chapters What Is Air Abrasion? What Happens? The Pros and Cons Will I Feel Anything? Is Air ... will perform any procedures that use air-abrasion technology. Ask your dentist if he or she uses ...

  16. Formerly utilized MED/AEC sites remedial action program. Radiological survey of the former Horizons, Inc., metal handling facility, Cleveland, Ohio. Final report

    International Nuclear Information System (INIS)

    Leggett, R.W.; Cottrell, W.D.; Shinpaugh, W.H.; Doane, R.W.; Haywood, F.F.; Johnson, W.M.

    1979-02-01

    The results of a radiological survey of the former Horizons, Inc., metal handling facility in Cleveland, Ohio, are presented in this report. During the 1940's and early 1950's, two of the three buildings on this site (Buildings B and C) were used for the production of granular thorium metal. The survey included measurements related to the following: fixed and transferable alpha and beta-gamma contamination levels on the surfaces in Buildings B and C and on the roofs of these buildings; external gamma radiation levels at 1 m above the floors and grounds on and near the property; radionuclide concentrations in soil, water, and other materials collected from surfaces and drains inside Buildings B and C, from beneath the floor in Building C, and from outdoor locations on and near the site; and thoron ( 220 Rn) daughter concentrations in the air in Buildings B and C. Elevated concentrations of 232 Th, 228 Ra, 228 Th, and 230 Th were found in some samples. Alpha and beta-gamma contamination levels exceeded applicable guideline limits in some areas of Buildings B and C. External gamma radiation levels, approximately 10 times the average background level, were measured at isolated points in and near Building B. Thorium B ( 212 Pb) concentrations in air in Building B were near the Radioactivity Concentration Guide (RCG) level. Most of the elevated radiation levels were found indoors in areas presently used for storage. Outdoors on and near the site, significant radiation levels were found only near the east wall of Building B

  17. Formerly utilized MED/AEC sites Remedial Action Program. Radiological survey of the former Watertown Arsenal property GSA site Watertown, Massachusetts

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Justus, A.L.; Flynn, K.F.

    1983-10-01

    The complete radiological survey of all the buildings located on the GSA site revealed no contamination. However, significant contamination was found on the site grounds. A total of approximately 6 m 2 of surface area exhibited elevated radiation levels. The area of contamination is centered around Section I (the burn area) and spreads out from this point. The contamination includes the subsurface, descending to the water table at the 6-ft level in some places. The contamination is primarily reprocessed depleted uranium. The ambient radiation level in the vicinity of the contamination as measured with a pressurized ionization chamber is significantly above background levels (up to 18 μR/h). As expected, no significant levels of radon contamination were found in any of the air samples. These levels of contamination of exceed the criteria as defined in ANSI 13.12 and the NRC Guidelines. The ambient radiation levels (up to 18 μR/h) are not in excess of criteria as defined in Appendix 6

  18. Formerly utilized MED/AEC Sites Remedial Action Program. Radiological survey of the former VITRO Rare Metals Plant, Canonsburg, Pennsylvania. Final report. [Plant to extract radium and uranium

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-06-01

    This 18-acre site was used from 1911 to 1922 to extract radium from carnotite ore, from 1930 to 1942 to extract radium and uranium salts from onsite residues and carnotite ore, and from 1942 to 1957 to recover uranium from various ores and scrap materials. The radiological survey was conducted in two phases, Phase I included measurement of radon and radon daughter concentrations in onsite buildings; concentrations measured in this part of the survey were all above guideline levels. Phase II consisted of measurement of surface contamination levels on the site, external gamma radiation levels at 1 m above surfaces on and near the site, radionuclide concentrations in surface and subsurface soil and water on and near the site, and radon concentrations in air at offsite locations. The results of the second phase of the survey indicate that large quantities of the radioactive wastes generated during radium and uranium recovery operations still remain on the site. Radium-bearing wastes are present in soil beneath or adjacent to each of the buildings on the site and in the top few feet of soil over almost the entire site, with some areas being contaminated to a depth of 16 ft or more. Alpha contamination levels, beta--gamma dose rates, and external gamma radiation levels in some areas of the buildings and outdoors on the site are above current federal guidelines concerning the release of property for unrestricted use. Concentrations of /sup 226/Ra in water in holes drilled on the site are above the maximum permissible concentration (MPC/sub w/). Also, measurements made offsite show that contamination from the site has spread to nearby offsite locations, and that there is significant atmospheric transport of /sup 222/Rn from the site.

  19. Formerly utilized MED/AEC sites Remedial Action Program. Report of the decontamination of Jones Chemical Laboratory, Ryerson Physical Laboratory, and Eckhart Hall, the University of Chicago, Chicago, Illinois

    International Nuclear Information System (INIS)

    Wynuveen, R.A.; Smith, W.H.; Sholeen, C.M.; Flynn, K.F.

    1984-08-01

    The US Department of Energy (DOE) has implemented a program to decontaminate radioactively contaminated sites that were formerly utilized by the Manhattan Engineer District (MED) and/or the Atomic Energy Commission (AEC) for activities that included handling of radioactive material. This program is referred to as the ''Formerly Utilized Sites Remedial Action Program'' (FUSRAP). Among these sites are Jones Chemical Laboratory, Ryerson Physical Laboratory, Kent Chemical Laboratory, and Eckhart Hall of The University of Chicago, Chicago, Illinois. Since 1977, the University of Chicago decontaminated Kent Chemical Laboratory as part of a facilities renovation program. All areas of Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory that had been identified as contaminated in excess of current guidelines in the 1976-1977 surveys were decontaminated to levels where no contamination could be detected relative to natural backgrounds. All areas that required defacing to achieve this goal were restored to their original condition. The radiological evaluation of the sewer system, based primarily on the radiochemical analyses of sludge and water samples, indicated that the entire sewer system is potentially contaminated. While this evaluation was defined as part of this project, the decontamination of the sewer system was not included in the purview of this effort. The documentation included in this report substantiates the judgment that all contaminated areas identified in the earlier reports in the three structures included in the decontamination effort (Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory) were cleaned to levels commensurate with release for unrestricted use

  20. The state of transboundary air pollution. Report prepared within the framework of the Convention on Long-range Transboundary Air Pollution

    International Nuclear Information System (INIS)

    1996-01-01

    This twelfth volume of the series of Air Pollution Studies, published under the auspices of the Executive Body for the Convention on Long-range Transboundary Air Pollution, contains the documents reviewed and approved for publication at the thirteenth session of the Executive Body held at Geneva from 28 November to 1 December 1995. Part One is the Annual Review of Strategies and Policies for Air Pollution Abatement. Part Two is an executive summary of the 1994 Report on the Forest Condition in Europe. The main objective of this report is to give a condensed description of the condition of forests in Europe, as it has been assessed by the transnational and national annual surveys, carried out jointly by ECE under the Convention on Long-range Transboundary Air Pollution and by the European Community (EC). Part Three is a summary report on the development of a library of default values for each of the input variables to the simple mass balance equation for the calculation of critical loads of nitrogen and for a range of ecosystems. Part Four presents the modelling results of European sulphur and nitrogen emissions, depositions for 1980 and 1993, and export/import budgets

  1. Air pollution

    OpenAIRE

    MacKenbach, JP; Henschel, S; Goodman, P; McKee, M

    2013-01-01

    The human costs of air pollution are considerable in Jordan. According to a report published in 2000 by the World Bank under the Mediterranean Environmental Technical Assistance Program (METAP), approximately 600 people die prematurely each year in Jordan because of urban pollution. 50-90% of air pollution in Jordanian towns is caused by road traffic. Readings taken in 2007 by Jordanian researchers showed that levels of black carbon particles in the air were higher in urban areas (caused by v...

  2. Formerly utilized MED/AEC sites Remedial Action Program. Report of the decontamination of Jones Chemical Laboratory, Ryerson Physical Laboratory, and Eckhart Hall, the University of Chicago, Chicago, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    Wynuveen, R.A.; Smith, W.H.; Sholeen, C.M.; Flynn, K.F.

    1984-08-01

    The US Department of Energy (DOE) has implemented a program to decontaminate radioactively contaminated sites that were formerly utilized by the Manhattan Engineer District (MED) and/or the Atomic Energy Commission (AEC) for activities that included handling of radioactive material. This program is referred to as the ''Formerly Utilized Sites Remedial Action Program'' (FUSRAP). Among these sites are Jones Chemical Laboratory, Ryerson Physical Laboratory, Kent Chemical Laboratory, and Eckhart Hall of The University of Chicago, Chicago, Illinois. Since 1977, the University of Chicago decontaminated Kent Chemical Laboratory as part of a facilities renovation program. All areas of Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory that had been identified as contaminated in excess of current guidelines in the 1976-1977 surveys were decontaminated to levels where no contamination could be detected relative to natural backgrounds. All areas that required defacing to achieve this goal were restored to their original condition. The radiological evaluation of the sewer system, based primarily on the radiochemical analyses of sludge and water samples, indicated that the entire sewer system is potentially contaminated. While this evaluation was defined as part of this project, the decontamination of the sewer system was not included in the purview of this effort. The documentation included in this report substantiates the judgment that all contaminated areas identified in the earlier reports in the three structures included in the decontamination effort (Eckhart Hall, Ryerson Physical Laboratory, and Jones Chemical Laboratory) were cleaned to levels commensurate with release for unrestricted use.

  3. Design of a Low-Power, Small-Area AEC-Q100-Compliant SENT Transmitter in Signal Conditioning IC for Automotive Pressure and Temperature Complex Sensors in 180 Nm CMOS Technology

    Science.gov (United States)

    Rikhan, Behnam Samadpoor; Kim, Dong-Gyu; Lee, Dong-Soo; Rehman, Muhammad Riaz Ur; Abbasizadeh, Hamed; Asif, Muhammad; Lee, Minjae; Yang, Youngoo; Lee, Kang-Yoon

    2018-01-01

    In this paper, a low-power and small-area Single Edge Nibble Transmission (SENT) transmitter design is proposed for automotive pressure and temperature complex sensor applications. To reduce the cost and size of the hardware, the pressure and temperature information is processed with a single integrated circuit (IC) and transmitted at the same time to the electronic control unit (ECU) through SENT. Due to its digital nature, it is immune to noise, has reduced sensitivity to electromagnetic interference (EMI), and generates low EMI. It requires only one PAD for its connectivity with ECU, and thus reduces the pin requirements, simplifies the connectivity, and minimizes the printed circuit board (PCB) complexity. The design is fully synthesizable, and independent of technology. The finite state machine-based approach is employed for area efficient implementation, and to translate the proposed architecture into hardware. The IC is fabricated in 1P6M 180 nm CMOS process with an area of (116 μm × 116 μm) and 4.314 K gates. The current consumption is 50 μA from a 1.8 V supply with a total 90 μW power. For compliance with AEC-Q100 for automotive reliability, a reverse and over voltage protection circuit is also implemented with human body model (HBM) electro-static discharge (ESD) of +6 kV, reverse voltage of −16 V to 0 V, over voltage of 8.2 V to 16 V, and fabricated area of 330 μm × 680 μm. The extensive testing, measurement, and simulation results prove that the design is fully compliant with SAE J2716 standard. PMID:29757996

  4. Airborne radioiodine species sampler and it's application for measuring removal efficiencies of large charcoal adsorbers for ventilation exhaust air

    International Nuclear Information System (INIS)

    Emel, D.; Hetzer, D.; Pelletier, C.A.; Barefoot, E.D.; Cline, J.E.

    1976-01-01

    A program, sponsored by the Electric Power Research Institute, is underway to determine the chemical species of radioiodine coming from LWR power plants and their persistence in the nearby environment. In support of this program, an airborne radioiodine sampler, developed and used by the AEC was modified and tested. This sampler consists of five components. The components are: (1) a particulate filter, (2) CdI 2 on a matrix of chromosorb-P to retain I 2 , (3) 4-Iodophenol on a matrix of activated alumina to retain HOI, (4) silver exchanged molecular sieve-13X to retain organic iodides, and (5) impregnated charcoal to serve as a control. The AEC sampler has not been proof-tested for periods over 48 hours or for flow rates above 0.10 l/s. For maximum sensitivity, a sampler is required to be used for periods of one to two weeks and at a flow rate giving a bed residence time of 0.1 sec. The AEC sampler was scaled up in size to attain an air sampling rate of 0.9 l/s. Each media for this sampler (except the particulate filter) was tested in the laboratory for retention of the iodine species; I 2 , Organic, and HOI. The tests were conducted at typical conditions observed at the main iodine release points at nuclear power plants. Confirmatory tests were run at operating nuclear power plants. The test results showed that under normal plant conditions the sampler could be operated at flow rates up to 0.80 l/s and differentiate the iodine species I 2 , HOI, and CH 3 I. The retention efficiencies of each media for its specie of radioiodine were found to be: I 2 on CdI 2 - 87 +- 5%, HOI on IPH 94 +- 4%, and CH 3 I on Ag 13-X or KI charcoal 99 +- 1%

  5. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  6. A review of the AEC in Pakistan

    International Nuclear Information System (INIS)

    Faruqui, A.M.

    1972-01-01

    In September this year the Pakistan Atomic Energy Commission completed six years of working with nuclear energy. Its expansion in all fields, both in research and practical application, has shown remarkable progress. This outline has been specially written by Mr. Akhtar Mahmud Faruqui, Director, Scientific Information and Public Relations, PAEC. (author)

  7. Air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, W; Mainwaring, S J

    1984-01-01

    This book deals with the nature of air pollution. The numerous sources of unwanted gases and dust particles in the air are discussed. Details are presented of the effects of pollutants on man, animals, vegetation and on inanimate materials. Methods used to measure, monitor and control air pollution are presented. The authors include information on the socio-economic factors which impinge on pollution control and on the problems the future will bring as methods of generating energy change and industries provide new sources of pollutants.

  8. Air lasing

    CERN Document Server

    Cheng, Ya

    2018-01-01

    This book presents the first comprehensive, interdisciplinary review of the rapidly developing field of air lasing. In most applications of lasers, such as cutting and engraving, the laser source is brought to the point of service where the laser beam is needed to perform its function. However, in some important applications such as remote atmospheric sensing, placing the laser at a convenient location is not an option. Current sensing schemes rely on the detection of weak backscattering of ground-based, forward-propagating optical probes, and possess limited sensitivity. The concept of air lasing (or atmospheric lasing) relies on the idea that the constituents of the air itself can be used as an active laser medium, creating a backward-propagating, impulsive, laser-like radiation emanating from a remote location in the atmosphere. This book provides important insights into the current state of development of air lasing and its applications.

  9. Air Warfare

    Science.gov (United States)

    2002-03-01

    genus as its predecessor of pre-war days. It would, however, be erroneous to conclude from this that the military value of each new development was...the paucity of communications, its conduct, when acting alone, has of necessity to be somewhat stereotyped in nature, and to con- form to a pre...the air, the attack commander, provided his command be equipped with defensive air power, has a rôle to perform which is simple and stereotyped in

  10. Air conditioner

    International Nuclear Information System (INIS)

    Sato, Masaaki

    1993-01-01

    The present invention provides an air conditioner which can prevent an undesirable effects on a human body due to radon daughter nuclides in a closed space. That is, the concentration of the radon daughter nuclides in the air in the closed space is continuously measured. A necessary amount of ventilation air is determined based on the measured concentration to generate control signals. External air is introduced into the closed space by the generated control signals. With such procedures, necessary amount of external air is taken from the atmospheric air which can be regarded to have the radon daughter nuclide concentration substantially at zero, thereby enabling to reduce the concentration of the radon daughter nuclides in the closed space. As a result, undesired effects on the human body due to the radon daughter nuclides staying in the closed space can be prevented. According to simulation, the radon daughter nuclides are rapidly decreased only by ventilation only for three times or so in one hour. Accordingly, ventilation is extremely effective and convenient means as a countermeasure for the radon daughter nuclides. (I.S.)

  11. Tonopah Test Range Air Monitoring: CY2016 Meteorological, Radiological, and Wind Transported Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Jenny [Desert Research Inst. (DRI), Las Vegas, NV (United States); Nikolich, George [Desert Research Inst. (DRI), Las Vegas, NV (United States); Shadel, Craig [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Las Vegas, NV (United States); Etyemezian, Vicken [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J [Desert Research Inst. (DRI), Las Vegas, NV (United States); Mizell, Steve [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2017-10-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective of the monitoring effort is to determine if wind blowing across the Clean Slate sites is transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites.

  12. Air surveillance

    International Nuclear Information System (INIS)

    Patton, G.W.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995)

  13. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  14. Air pollution

    International Nuclear Information System (INIS)

    Feugier, A.

    1996-01-01

    The air pollution results from the combustion of petroleum products, natural gas, coal, wastes and transports. Some compounds are considered as particularly pollutants: the carbon monoxide, the nitrogen oxides, the tropospheric ozone and the sulfur dioxides. Their environmental and biological effects are described. The present political guide lines concerns the combustion plants, the ozone, the wastes incineration and the vehicles emissions. The aim is at some future date to control the air quality, to reduce the volatile organic compounds emissions and to limit the sulfur rate of some petroleum products. (O.L.)

  15. Effects and control of long-range transboundary air pollution. Report prepared within the framework of the Convention on Long-range Transboundary Air Pollution

    International Nuclear Information System (INIS)

    1995-01-01

    This eleventh volume of the series of Air Pollution Studies, published under the auspices of the Executive Body for the Convention on Long-range Transboundary Air Pollution, contains the documents reviewed and approved for publication at the twelfth session of the Executive Body held at Geneva from 28 November to 1 December 1994. Part one focuses on the possible impact of acid deposition on the quality of groundwater in the ECE region. The objective of this report is to present an updated review of available knowledge on the possible impact of deposition of sulphur and nitrogen compounds on the status of groundwater, including a brief survey of recent research results in this field. It updates an earlier report on the effects of air pollutants on groundwater, prepared within the Convention (EB.AIR/WG.1/R.9). Part two is an executive summary of the 1993 Report on the Forest Condition in Europe (Forest Condition in Europe. Results of the 1993 Survey. 1994 Report, EC-UN/ECE, Brussels, Geneva, 1994). The report describes the results of both the national and the transnational surveys which are conducted annually within the International Cooperative Programme on the Assessment and Monitoring of Air Pollution Effects on Forests (ICP Forests) of the United Nations Economic Commission for Europe (ECE) and under European Community Council Regulation (EEC) 3528/86 on the protection of the Community's Forests against Atmospheric Pollution. Part three is a summary report on the options for further reduction of nitrogen oxide emissions from road heavy-duty vehicles (HDVs). This report is primarily focused on reduction options for road HDVs, but some of the technical measures reviewed can, however, also be applied to some non-road diesel engines, such as machinery in construction, agriculture or forestry

  16. Air pollution

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    Air pollution has accompanied and developed with the industrial age, since its beginnings. This very complete review furnishes the toxicological data available for the principal pollutants and assesses the epidemiologic studies thus far conducted. It also describes European regulations and international commitments for the reduction of emissions. (author)

  17. Air quality

    International Nuclear Information System (INIS)

    1995-01-01

    This chapter of the 'Assessment of the state of the environment in Lebanon' describes the air quality and identifies the most important air quality issues. Baseline information about the factors affecting dispersion and the climate of Lebanon presents as well and overall estimation of total emissions in Lebanon. Emissions from vehicles, electricity and power plants generation are described. Industrial emitters of air pollutants are described for each kind of industry i.e.cement plants, Selaata fertilizer factory, sugar-beet factory, refineries and for those derived from the use of leaded fuel . Impact of economic and human activities on air quality in Lebanon (especially in Beirut and Tripoli) are quantified by quantities of CO 2 , SO 2 , NO x , total suspended particulates(TSP), deposition and their environmental effects on health. In abscence of emissions monitoring, data available are expressed in terms of fuel use, output and appropriate empirical factors, national output and workfores sizes. Finally key issues and some potential mitigation /management approaches are presented

  18. Royal Danish Air Force. Air Operations Doctrine

    DEFF Research Database (Denmark)

    Nørby, Søren

    This brief examines the development of the first Danish Air Force Air Operations Doctrine, which was officially commissioned in October 1997 and remained in effect until 2010. The development of a Danish air power doctrine was heavily influenced by the work of Colonel John Warden (USAF), both...... through his book ”The Air Campaign” and his subsequent planning of the air campaign against Iraq in 1990-1991. Warden’s ideas came to Denmark and the Danish Air Force by way of Danish Air Force students attending the United States Air Force Air University in Alabama, USA. Back in Denmark, graduates from...... the Air University inspired a small number of passionate airmen, who then wrote the Danish Air Operations Doctrine. The process was supported by the Air Force Tactical Command, which found that the work dovetailed perfectly with the transformation process that the Danish Air Force was in the midst...

  19. Case Studies in Policy Making. Twelfth Edition

    Science.gov (United States)

    2010-01-01

    1185.html. 44. Howard La Franchi , “US Seeks Global Aid for Iraq,” Christian Science Monitor, 21 Jan- uary 2004, 1. 45. Phillips, Losing Iraq, 180. 46...military actions. International trends, such as conflicting norms, globalization , and emerging technology, also play a critical role. The domestic...polarity, or distribution of power within the IPS, whether or not a particular actor possessed weapons of mass destruction, a global dependency on oil

  20. Educational Technology: Kindergarten through Twelfth Grade.

    Science.gov (United States)

    Steinhaus, Kurt A.

    This report presents the findings and conclusions of a study of educational technology in New Mexico schools. Designed to provide baseline information to the New Mexico Education Technology Planning Committee, the results of the study will also be used to help make statewide planning decisions concerning educational technology. The findings…

  1. Occupational radiation exposure. Twelfth annual report, 1979

    International Nuclear Information System (INIS)

    Brooks, B.; McDonald, S.; Richardson, E.

    1982-08-01

    This report summarizes the occupational exposure data that is maintained in the US Nuclear Regulatory Commission's Radiation Exposure Information and Reports System (REIRS). This report is usually published on an annual basis and is available at all NRC public document rooms. The bulk of the information contained in the report was extracted from annual statistical reports submitted by all NRC licensees subject to the reporting requirements of 10 CFR 20.407. Four categories of licensees - operating nuclear power reactors, fuel fabricators and reprocessors, industrial radiographers, and manufacturers and distributors of specified quantities of byproduct materials - also submit personal identification and exposure information for terminating employees pursuant to 10 CFR 20.408, and some analysis of this data is also presented in this report

  2. diagnosing the diagnostics: misconceptions of twelfth grade ...

    African Journals Online (AJOL)

    Preferred Customer

    In the area of chemical research, a significant number of studies involving ... be introduced as similar concepts in early high school (3). Second, the ..... misconceptions about physics concepts in Yasin, K. (2004), a M.Sc. dissertation thesis.

  3. Air quality

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    The anthropic pollution sources are essentially industrial or bound to transport. A phenomenon of these last twenty years is the decreasing of the industrial pollution and the increasing of pollution coming from automobiles. Emissions of furans and dioxines coming from municipal wastes are measured. A special attention is mentioned for polycyclic aromatic hydrocarbons coming from incomplete combustions. A last aspect of air pollution is studied with the effect on man, ecosystems and materials, by modeling or direct measurements. (N.C.)

  4. Air pollution

    International Nuclear Information System (INIS)

    Nelson, P.

    2000-01-01

    Australian cites experience a number of current and emerging air pollution problems. Concentrations of traditional primary pollutants such as CO, lead and dust have fallen in recent years as a consequence of air pollutant control measures, and the widespread introduction of lead-free petrol. However, recommended guidelines for ozone, the principal component of photochemical smog, are regularly exceeded in major capital cities in the summer months. In addition, it is predicted that extensive urban expansion will lead to much greater dependence on the motor vehicle as the primary means of transportation. Effects of air pollution are felt at a variety of scales. Traditionally, concerns about gaseous and particulate emissions from industrial and vehicular sources were focused on local impacts due to exposure to toxic species such as CO and lead. As noted above, concentrations of these pollutants have been reduced by a variety of control measures. Pollutants which have effects at a regional scale, such as photochemically-produced ozone, and acidic gases and particles have proved more difficult to reduce. In general, these pollutants arc not the result of direct emissions to atmosphere, but result from complex secondary processes driven by photochemical reactions of species such as NO 2 and aldehydes. In addition, global effects of gaseous and particulate emissions to the atmosphere have received significant recent attention, concentrations of atmospheric CO 2 with predicted impacts on global climate, and ozone depletion due to anthropogenic emissions of chlorine-containing chemicals are the two major examples. Combustion processes from petrol- and diesel-fuelled vehicles, make major contributions to air pollution, and the magnitude of this contribution is discussed in this article

  5. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  6. Hazardous Air Pollutants

    Science.gov (United States)

    ... Search Main menu Environmental Topics Air Bed Bugs Chemicals and Toxics Environmental Information by Location Greener Living Health Land, ... regulate toxic air pollutants, also known as air toxics, from categories of industrial facilities in two phases . About Hazardous Air Pollutants ...

  7. Air Quality System (AQS)

    Science.gov (United States)

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  8. AirData

    Data.gov (United States)

    U.S. Environmental Protection Agency — The AirData site provides access to yearly summaries of United States air pollution data, taken from EPA's air pollution databases. AirData has information about...

  9. AEC Scorecard Phase IV: Furthering the Implementation of the AEC Blueprint Measures The Singapore Country Report

    OpenAIRE

    Hank LIM; Bernard AW; LOKE Hoe Yeong

    2015-01-01

    Singapore is an open economy that is critically dependent on leveraging external resources to achieve its economic growth. To achieve that objective, the government is strongly committed to maintaining a free and competitive economy. In the case of service liberalisation, however, there are a number of restrictions on foreign labour in the service sectors under review that may have an adverse impact on the service sectors. Nonetheless, Singapore is ready to integrate fully into the Associatio...

  10. Aeromedical Evacuation: Validating Civil Reserve Air Fleet

    Science.gov (United States)

    2009-02-25

    flight nurses and three medical technicians) is added for AE missions. The aeromedical evacuation crew (AEC) may be pared and tailored as required in... Biosecurity and Bioterrorism: Biodefense Strategy, Practice and Science, Volume 5, Number 4, 2007: 319-325. 34 IAT.R 0554 General Accounting Office

  11. Air Land Sea Bulletin

    Science.gov (United States)

    2014-11-01

    Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based at Royal Air Force Honington, Suffolk (United...heavy as an actual weapon.4 Ideally, this practice imbued a soldier with more energy and stamina during real combat, given the feel of the genuine but...through tactical forces, to individual training. Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based

  12. 12th Air Force > Home

    Science.gov (United States)

    Force AOR Travel Info News prevnext Slide show 76,410 pounds of food delivered to Haiti 12th Air Force the French Air Force, Colombian Air Force, Pakistan Air Force, Belgian Air Force, Brazilian Air Force

  13. Wisconsin Air Cargo Study

    Science.gov (United States)

    2011-04-01

    Air cargo is a key economic lifeline for the communities that have airports. Manufacturers, businesses, hospitals and : other community cornerstone employers depend on air cargo to successfully operate. While there is no doubt that air : cargo repres...

  14. HEPA air filter (image)

    Science.gov (United States)

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  15. Air Sensor Toolbox

    Science.gov (United States)

    Air Sensor Toolbox provides information to citizen scientists, researchers and developers interested in learning more about new lower-cost compact air sensor technologies and tools for measuring air quality.

  16. GSPEL - Air Filtration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Evaluation capabilities for air filtration devicesThe Air Filtration Lab provides testing of air filtration devices to demonstrate and validate new or legacy system...

  17. Indoor Air Quality

    Science.gov (United States)

    ... protect yourself and your family. Learn more Air Quality at Work Workers should breathe easy while on the job, but worksites with poor air quality put employees at risk. Healthy air is essential ...

  18. Air Pollution Monitoring | Air Quality Planning & Standards ...

    Science.gov (United States)

    2016-06-08

    The basic mission of the Office of Air Quality Planning and Standards is to preserve and improve the quality of our nation's air. To accomplish this, OAQPS must be able to evaluate the status of the atmosphere as compared to clean air standards and historical information.

  19. AirPEx: Air Pollution Exposure Model

    NARCIS (Netherlands)

    Freijer JI; Bloemen HJTh; Loos S de; Marra M; Rombout PJA; Steentjes GM; Veen MP van; LBO

    1997-01-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The

  20. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  1. Kajian Analitik Perencanaan Pintu Air Pembangkit Listrik Tenaga Air

    OpenAIRE

    Pradoto, Pradoto

    1993-01-01

    Pada pintu air pembangkit listrik tenaga air umumnya dipasang pengauat-penguat (girder). Tujuannya agar pintu air kuat dalam menahan tekanan air. Tekanan air yang diderita oleh pintu air cukup besar karena dipasang pada kedalaman + 50 meter di bawah permukaan air. Permasalahan yang timbul adalah menentukan posisi atau letak girder pada pintu air.

  2. Formerly utilized MED/AEC sites Remedial Action Program. Radiological survey of the St. Louis Airport Storage Site, St. Louis, Missouri. Final report. [U, Ra-bearing wastes stored in 1940-60's

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-09-01

    Results of two radiological surveys of the St. Louis-Lambert Airport property, formerly known as the Airport Storage Site, St. Louis, Missouri, are presented. Uranium- and radium-bearing waste materials were stored from the 1940's to the late 1960's in this area. The surveys included direct measurements of beta-gamma radiation; determination of uranium, actinium, and radium concentrations in soil samples and from bore holes; determination of radionuclide concentrations in groundwater and surface water; measurement of radon flux from the ground surface; and measurements of /sup 222/Rn in air near the site. Results indicate that some offsite drainage pathways are becoming contaminated, probably by runoff from the site; no migration of /sup 222/Rn from the site was observed.

  3. AirPEx. Air Pollution Exposure Model

    Energy Technology Data Exchange (ETDEWEB)

    Freijer, J.I.; Bloemen, H.J.Th.; De Loos, S.; Marra, M.; Rombout, P.J.A.; Steentjes, G.M.; Van Veen, M.P.

    1997-12-01

    Analysis of inhalatory exposure to air pollution is an important area of investigation when assessing the risks of air pollution for human health. Inhalatory exposure research focuses on the exposure of humans to air pollutants and the entry of these pollutants into the human respiratory tract. The principal grounds for studying the inhalatory exposure of humans to air pollutants are formed by the need for realistic exposure/dose estimates to evaluate the health effects of these pollutants. The AirPEx (Air Pollution Exposure) model, developed to assess the time- and space-dependence of inhalatory exposure of humans to air pollution, has been implemented for use as a Windows 3.1 computer program. The program is suited to estimating various exposure and dose quantities for individuals, as well as for populations and subpopulations. This report describes the fundamentals of the AirPEx model and provides a user manual for the computer program. Several examples included in the report illustrate the possibilities of the AirPEx model in exposure assessment. The model will be used at the National Institute of Public Health and the Environment as a tool in analysing the current exposure of the Dutch population to air pollutants. 57 refs.

  4. Air pollution and the school air environment

    OpenAIRE

    Fsadni, Peter; Montefort, Stephen

    2015-01-01

    There is growing concern about the association of school indoor air quality (SIAQ) with asthma, rhinitis, and rhinoconjunctivitis. Students and school staff deserve the highest standards of school air quality to ensure a safe and productive environment for our children’s education. Existing studies highlight the presence of several air pollutants present within school classrooms that have a direct association with poor health and poor student performance. Very little data exist ab...

  5. Connectable solar air collectors

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S.; Bosanac, M.

    2002-02-01

    The project has proved that it is possible to manufacture solar air collector panels, which in an easy way can be connected into large collector arrays with integrated ducting without loss of efficiency. The developed connectable solar air collectors are based on the use of matrix absorbers in the form of perforated metal sheets. Three interconnected solar air collectors of the above type - each with an transparent area of approx. 3 m{sup 2} - was tested and compared with parallel tests on two single solar air collectors also with a transparent area of approx. 3 m{sup 2} One of the single solar air collectors has an identical absorber as the connectable solar air collectors while the absorber of the other single solar air collector was a fibre cloth. The efficiency of the three solar air collectors proved to be almost identical in the investigated range of mass flow rates and temperature differences. The solar air collectors further proved to be very efficient - as efficient as the second most efficient solar air collectors tested in the IEA task 19 project Solar Air Systems. Some problems remain although to be solved: the pressure drop across especially the connectable solar air collectors is too high - mainly across the inlets of the solar air collectors. It should, however, be possible to considerably reduce the pressure losses with a more aerodynamic design of the inlet and outlet of the solar air collectors; The connectable solar air collectors are easy connectable but the air tightness of the connections in the present form is not good enough. As leakage leads to lower efficiencies focus should be put on making the connections more air tight without loosing the easiness in connecting the solar air collectors. As a spin off of the project a simple and easy way to determine the efficiency of solar, air collectors for pre-heating of fresh air has been validated. The simple method of determining the efficiency has with success been compared with an advance method

  6. Air conditioning systems to clean radioactive air

    International Nuclear Information System (INIS)

    Ganz, G.

    1987-01-01

    The author reports a study by the Institutes fuer Klimatechnik and Umweltschutz Giessen that shows that air conditioning systems not only make the atmosphere more comfortable, they also extract dust particles. This cleaning action is also valid for radioactively contaminated air. (G.T.H./Auth.)

  7. Air movement and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Kaczmarczyk, J.

    2012-01-01

    The impact of air movement on perceived air quality (PAQ) and sick building syndrome (SBS) symptoms was studied. In total, 124 human subjects participated in four series of experiments performed in climate chambers at different combinations of room air temperature (20, 23, 26 and 28 °C), relative...... and the humidity of the room air. At a low humidity level of 30% an increased velocity could compensate for the decrease in perceived air quality due to an elevated temperature ranging from 20 °C to 26 °C. In a room with 26 °C, increased air movement was also able to compensate for an increase in humidity from 30...... humidity (30, 40 and 70%) and pollution level (low and high). Most of the experiments were performed with and without facially applied airflow at elevated velocity. The importance of the use of recirculated room air and clean, cool and dry outdoor air was studied. The exposures ranged from 60. min to 235...

  8. Simple air collectors for preheating fresh air

    NARCIS (Netherlands)

    Hensen, J.L.M.; Wit, de M.H.; Ouden, den C.

    1984-01-01

    In dwellings with mechanical ventilation systems the fresh air can easily be preheated by means of simple solar air systems. These can be an integral part of the building facade or roof and the costs are expected to be low. By means of computer experiments a large number of systems were evaluated.

  9. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Facilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  10. Allegheny County Air Quality

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Air quality data from Allegheny County Health Department monitors throughout the county. Air quality monitored data must be verified by qualified individuals before...

  11. Air Quality System (AQS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements...

  12. Lead (Pb) Air Pollution

    Science.gov (United States)

    ... Regional Offices Labs and Research Centers Lead (Pb) Air Pollution Contact Us Share As a result of EPA's ... and protect aquatic and terrestrial ecosystems. Lead (Pb) Air Pollution Basic Information How does lead get in the ...

  13. Indoor Air Pollution

    Science.gov (United States)

    We usually think of air pollution as being outdoors, but the air in your house or office could also be polluted. Sources of indoor pollution include Mold and pollen Tobacco smoke Household products ...

  14. Nuclear air cleaning

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1994-01-01

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  15. AirCompare

    Data.gov (United States)

    U.S. Environmental Protection Agency — AirCompare contains air quality information that allows a user to compare conditions in different localities over time and compare conditions in the same location at...

  16. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  17. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  18. AIR NCO's AND AIRMEN

    African Journals Online (AJOL)

    D.F.C. o Proceeded to Cape Town 9:5:22. Left Cape Town for. African Protectorate 25:2:22. J Left for South West African Protectorate 25:2:22. [ Left for South West African Protectorate. 1:6:22. Colonel: Director of Air Services. Air Directorate. 6th June 1922. SOUTH AFRICAN AIR FORCE. NOMINAL ROLL OF AIR W.O.'s,.

  19. Air Pollution Training Programs.

    Science.gov (United States)

    Public Health Service (DHEW), Rockville, MD.

    This catalog lists the universities, both supported and not supported by the Division of Air Pollution, which offer graduate programs in the field of air pollution. The catalog briefly describes the programs and their entrance requirements, the requirements, qualifications and terms of special fellowships offered by the Division of Air Pollution.…

  20. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.

  1. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  2. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  3. Air quality and disease

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Climate change is an important determinant of air quality. Climate change is an important determinant of air quality. Poor air quality associated with higher levels of respiratory and cardiovascular disease. Exposure to high levels of ground-level ozone associated with ...

  4. Air Force Leadership Diversity

    Science.gov (United States)

    2017-04-06

    served as a deputy maintenance group commander. Following Air War College he will take command of the 8th Maintenance Group, Kunsan Air Base, Korea ...discrimination in terms of 3 race, religion , sex, etc.: the demographics we have all heard about for years. Air Force Policy Directive (AFPD) 36

  5. Manual for THOR-AirPAS - air pollution assessment system

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Ketzel, Matthias; Brandt, Jørgen

    The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS.......The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS....

  6. Photochemical air pollution

    International Nuclear Information System (INIS)

    Te Winkel, B.H.

    1992-01-01

    During periods of severe photochemical air pollution (smog) the industry in the Netherlands is recommended by the Dutch government to strongly reduce the emissions of air pollutants. For the electric power generating companies it is important to investigate the adequacy of this policy. The purpose of this investigation is to determine the contribution of electric power plants to photochemical air pollution and to assess the efficacy of emission reducing measures. A literature survey on the development of photochemical air pollution was carried out and modelled calculations concerning the share of the electric power plants to the photochemical air pollution were executed

  7. Air-water screen

    Energy Technology Data Exchange (ETDEWEB)

    Prokopov, O.I.; Kutepov, A.I.

    1980-12-08

    The air-water screen based on inventor's certificate No. 577364 contains horizontal water and air lines with water and air nozzles. The air line is situated inside the water line eccentrically and contracts it in the area of the nozzle, whose orifices are situated along the line of contact, while the orifices of the water nozzle are situated symmetrically relative to the air orifices and are located at an acute angle to them. To raise the protective properties, on the end of the water line is a lateral nozzle water distributor is an additional nozzle, connected to this container.

  8. Air Conditioner/Dehumidifier

    Science.gov (United States)

    1986-01-01

    An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

  9. Air filtration and air cooling in dairies

    Energy Technology Data Exchange (ETDEWEB)

    Rubzov, J A

    1986-01-01

    In addition to the maintenance of optimum temperatures and relative humidities, a continuous cleaning of the circulating air by means of suspended matter filters and regular disinfection of the spaces and equipment are required in the maturing and storage room for cheese. This contribution presents solutions to the use of suspended matter filters in air cooling plant for dairies in the U.S.S.R.

  10. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  11. Health Effects of Air Pollution

    Science.gov (United States)

    ... Health effects of air pollution Health effects of air pollution Breathing air that is not clean can hurt ... important to know about the health effects that air pollution can have on you and others. Once you ...

  12. Liberalisation of air cargo transport

    Science.gov (United States)

    2002-05-02

    Over a period of many years, international air cargo demand has continued to increase more rapidly than international air passenger demand. Air cargo arrangements need to be as efficient and expeditious as possible, to meet user requirements for air ...

  13. Released air during vapor and air cavitation

    Energy Technology Data Exchange (ETDEWEB)

    Jablonská, Jana, E-mail: jana.jablonska@vsb.cz; Kozubková, Milada, E-mail: milada.kozubkova@vsb.cz [VŠB-Technical University of Ostrava, Faculty of Mechanical Engineering, Department of Hydromechanics and Hydraulic Equipment, 17. listopadu 15, 708 33 Ostrava-Poruba (Czech Republic)

    2016-06-30

    Cavitation today is a very important problem that is solved by means of experimental and mathematical methods. The article deals with the generation of cavitation in convergent divergent nozzle of rectangular cross section. Measurement of pressure, flow rate, temperature, amount of dissolved air in the liquid and visualization of cavitation area using high-speed camera was performed for different flow rates. The measurement results were generalized by dimensionless analysis, which allows easy detection of cavitation in the nozzle. For numerical simulation the multiphase mathematical model of cavitation consisting of water and vapor was created. During verification the disagreement with the measurements for higher flow rates was proved, therefore the model was extended to multiphase mathematical model (water, vapor and air), due to release of dissolved air. For the mathematical modeling the multiphase turbulence RNG k-ε model for low Reynolds number flow with vapor and air cavitation was used. Subsequently the sizes of the cavitation area were verified. In article the inlet pressure and loss coefficient depending on the amount of air added to the mathematical model are evaluated. On the basis of the approach it may be create a methodology to estimate the amount of released air added at the inlet to the modeled area.

  14. Tonopah Test Range Air Monitoring: CY2015 Meteorological, Radiological, and Airborne Particulate Observations

    International Nuclear Information System (INIS)

    Nikolich, George; Shadel, Craig; Chapman, Jenny; McCurdy, Greg; Etyemezian, Vicken; Miller, Julianne J.; Mizell, Steve

    2016-01-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). The operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites. Radionuclide assessment of airborne particulates in 2015 found the gross alpha and gross beta values of dust collected from the filters at the monitoring stations are consistent with background conditions. The meteorological and particle monitoring indicate that conditions for wind-borne contaminant movement exist at the Clean Slate sites and that, although the transport of radionuclide-contaminated soil by suspension has not been detected, movement by saltation is occurring.

  15. Tonopah Test Range Air Monitoring: CY2015 Meteorological, Radiological, and Airborne Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Nikolich, George [Nevada University, Reno, NV (United States). Desert Research Inst.; Shadel, Craig [Nevada University, Reno, NV (United States). Desert Research Inst.; Chapman, Jenny [Nevada University, Reno, NV (United States). Desert Research Inst.; McCurdy, Greg [Nevada University, Reno, NV (United States). Desert Research Inst.; Etyemezian, Vicken [Nevada University, Reno, NV (United States). Desert Research Inst.; Miller, Julianne J. [Nevada University, Reno, NV (United States). Desert Research Inst.; Mizell, Steve [Nevada University, Reno, NV (United States). Desert Research Inst.

    2016-09-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). The operation resulted in radionuclide-contaminated soils at the Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III, and at the TTR Sandia National Laboratories (SNL) Range Operations Control (ROC) center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites. Radionuclide assessment of airborne particulates in 2015 found the gross alpha and gross beta values of dust collected from the filters at the monitoring stations are consistent with background conditions. The meteorological and particle monitoring indicate that conditions for wind-borne contaminant movement exist at the Clean Slate sites and that, although the transport of radionuclide-contaminated soil by suspension has not been detected, movement by saltation is occurring.

  16. Local Air Quality Conditions and Forecasts

    Science.gov (United States)

    ... Monitor Location Archived Maps by Region Canada Air Quality Air Quality on Google Earth Links A-Z About AirNow AirNow International Air Quality Action Days / Alerts AirCompare Air Quality Index (AQI) ...

  17. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  18. Bad traffic, bad air

    OpenAIRE

    Duca, Edward

    2012-01-01

    Air pollution is one of Malta’s greatest concerns. Transportation is the principal source with over 300,000 vehicles belching out smoke, which damages our environment and health. Emissions from vehicles need to be monitored and controlled, and the information used to improve the current system and ensure an acceptable air quality. By using the pollution data set, Nicolette Formosa (supervised by Dr Kenneth Scerri) mapped the air pollution levels and major sources around Malta. http://www....

  19. Radioactive material air transportation

    International Nuclear Information System (INIS)

    Pader y Terry, Claudio Cosme

    2002-01-01

    As function of the high aggregated value, safety regulations and the useful life time, the air transportation has been used more regularly because is fast, reliable, and by giving great security to the cargo. Based on the International Atomic Energy Agency (IAEA), the IATA (International Air Transportation Association) has reproduced in his dangerous goods manual (Dangerous Goods Regulations - DGR IATA), the regulation for the radioactive material air transportation. Those documents support this presentation

  20. Air pollution engineering

    Science.gov (United States)

    Maduna, Karolina; Tomašić, Vesna

    2017-11-01

    Air pollution is an environmental and a social problem which leads to a multitude of adverse effects on human health and standard of human life, state of the ecosystems and global change of climate. Air pollutants are emitted from natural, but mostly from anthropogenic sources and may be transported over long distances. Some air pollutants are extremely stable in the atmosphere and may accumulate in the environment and in the food chain, affecting human beings, animals and natural biodiversity. Obviously, air pollution is a complex problem that poses multiple challenges in terms of management and abatements of the pollutants emission. Effective approach to the problems of air pollution requires a good understanding of the sources that cause it, knowledge of air quality status and future trends as well as its impact on humans and ecosystems. This chapter deals with the complexities of the air pollution and presents an overview of different technical processes and equipment for air pollution control, as well as basic principles of their work. The problems of air protection as well as protection of other ecosystems can be solved only by the coordinated endeavors of various scientific and engineering disciplines, such as chemistry, physics, biology, medicine, chemical engineering and social sciences. The most important engineering contribution is mostly focused on development, design and operation of equipment for the abatement of harmful emissions into environment.

  1. Applications Using AIRS Data

    Science.gov (United States)

    Ray, S. E.; Pagano, T. S.; Fetzer, E. J.; Lambrigtsen, B.; Olsen, E. T.; Teixeira, J.; Licata, S. J.; Hall, J. R.; Thompson, C. K.

    2015-12-01

    The Atmospheric Infrared Sounder (AIRS) on NASA's Aqua spacecraft has been returning daily global observations of Earth's atmospheric constituents and properties since 2002. With a 12-year data record and daily, global observations in near real-time, AIRS data can play a role in applications that fall under many of the NASA Applied Sciences focus areas. For vector-borne disease, research is underway using AIRS near surface retrievals to assess outbreak risk, mosquito incubation periods and epidemic potential for dengue fever, malaria, and West Nile virus. For drought applications, AIRS temperature and humidity data are being used in the development of new drought indicators and improvement in the understanding of drought development. For volcanic hazards, new algorithms using AIRS data are in development to improve the reporting of sulfur dioxide concentration, the burden and height of volcanic ash and dust, all of which pose a safety threat to aircraft. In addition, anomaly maps of many of AIRS standard products are being produced to help highlight "hot spots" and illustrate trends. To distribute it's applications imagery, AIRS is leveraging existing NASA data frameworks and organizations to facilitate archiving, distribution and participation in the BEDI. This poster will communicate the status of the applications effort for the AIRS Project and provide examples of new maps designed to best communicate the AIRS data.

  2. Air University Press Publications

    National Research Council Canada - National Science Library

    2002-01-01

    .... Our publications program is designed primarily to help Air Force and other US war fighters, national leaders and policy makers, academicians, military historians, and other analysts understand...

  3. Electric air filtration movie

    International Nuclear Information System (INIS)

    Bergman, W.; Jaeger, R.

    1984-01-01

    The use of electrostatics to improve the performance of conventional air filters has gained considerable attention in recent years. This interest is due to the higher efficiency and reduced pressure drop of electrically enhanced filters compared to conventional fibrous filters. This 30-minute movie presents a state of the art review of electric air filters in the United States with major illustrations provided by the research and development program at the Lawrence Livermore National Laboratory sponsored by the Department of Energy. The electric air filters described in this movie are mechanical air filters to which electrical forces have been added

  4. Air pollution meteorology

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Daoo, V J [Environmental Assessment Div., Bhabha Atomic Research Centre, Mumbai (India)

    2002-06-01

    This report is intended as a training cum reference document for scientists posted at the Environmental Laboratories at the Nuclear Power Station Sites and other sites of the Department of Atomic Energy with installations emitting air pollutants, radioactive or otherwise. Since a manual already exists for the computation of doses from radioactive air pollutants, a general approach is take here i.e. air pollutants in general are considered. The first chapter presents a brief introduction to the need and scope of air pollution dispersion modelling. The second chapter is a very important chapter discussing the aspects of meteorology relevant to air pollution and dispersion modelling. This chapter is important because without this information one really does not understand the phenomena affecting dispersion, the scope and applicability of various models or their limitations under various weather and site conditions. The third chapter discusses the air pollution models in detail. These models are applicable to distances of a few tens of kilometres. The fourth chapter discusses the various aspects of meteorological measurements relevant to air pollution. The chapters are followed by two appendices. Apendix A discusses the reliability of air pollution estimates. Apendix B gives some practical examples relevant to general air pollution. It is hoped that the document will prove very useful to the users. (author)

  5. Influência de práticas maternas no desenvolvimento motor de lactentes do 6º ao 12º meses de vida Influence of child-rearing practices on infants' motor development between the sixth and twelfth months of life

    Directory of Open Access Journals (Sweden)

    PL Silva

    2006-01-01

    Full Text Available CONTEXTO: Práticas maternas são comportamentos específicos, por meio dos quais as mães/cuidadores desempenham suas tarefas maternais. Estas práticas poderiam influenciar o desenvolvimento motor de lactentes. OBJETIVO: verificar a influência de práticas maternas, utilizadas no cuidado diário de lactentes saudáveis, sobre seu desenvolvimento motor do 6º ao 12º meses de vida. MÉTODO: Selecionados 14 lactentes, nascidos a termo e saudáveis, avaliados longitudinalmente no 6º, 9º e 12º meses de vida, utilizando-se a Alberta Infant Motor Scale. Em cada avaliação/idade a mãe respondeu a um questionário fechado sobre práticas, predominantemente adotadas no cuidado diário do lactente durante os períodos de vigília. Considerou-se neste estudo a postura predominantemente adotada pelo lactente, local preferencial de permanência e a forma de carregar o lactente no colo. RESULTADOS: No 9º mês de vida o desempenho motor dos lactentes foi influenciado positivamente pela predominância na postura de quatro apoios, em relação à sentada e prono ou supino e pela permanência no chão em relação ao carrinho de bebê. No 12º mês houve influência positiva da predominância na postura de quatro apoios e em pé. A postura predominante no 6º mês de vida e a forma de carregar o lactente no 6º, 9º e 12º meses de vida não influenciaram o desempenho motor do grupo estudado. CONCLUSÃO: Os resultados sugerem que as práticas que estimulam a adoção da postura de quatro apoios e a utilização do chão como local de permanência influenciam positivamente o desenvolvimento motor de lactentes saudáveis a partir do 6º mês de vida.BACKGROUND: Child-rearing practices are defined as specific behavioral patterns used during maternal duties. These practices could influence infants' motor development. OBJECTIVE: To verify the influence of daily child-rearing practices on the motor development of healthy infants from their sixth to twelfth

  6. Maxwell Air Force Base

    Science.gov (United States)

    most effective style of leadership. (Courtesy Photo, Air University Press) Air University Press Directory Maxwell Links Welcome Leadership Joint Land Use Study Heritage Pamphlet Maxwell Driving Tour (No releases 'A Discourse on Winning and Losing' "Developing Your Full Range of Leadership" focuses

  7. Energy and air quality

    International Nuclear Information System (INIS)

    1981-12-01

    This is one of a series of handbooks designed to provide nontechnical readers with a general understanding of the interaction between energy development and environmental media and to provide a rudimentary data base from which estimates of potential future impacts can be made. This handbook describes the air quality impacts of energy development and summarizes the major federal legislation which regulates the potential air quality impacts of energy facilities and can thus influence the locations and timing of energy development. In addition, this report describes and presents the data which can be used as the basis for measurement, and in some cases, prediction of the potential conflicts between energy development and achieving and maintaining clean air. Energy utilization is the largest emission source of man-made air pollutants. Choices in energy resource development and utilization generate varying emissions or discharges into the atmosphere, the emissions are affected by the assimilative character of the atmosphere, and the resultant air pollutant concentrations have biological and aesthetic effects. This handbook describes the interrelationships of energy-related air emissions under various methods of pollution control, the assimilative character of the air medium, and the effects of air pollution. The media book is divided into three major sections: topics of concern relating to the media and energy development, descriptions of how to use available data to quantify and examine energy/environmental impacts, and the data

  8. Paradoxical cerebral air embolism

    International Nuclear Information System (INIS)

    Lopez-Negrete, L.; Garcia-Lozano, J.; Sanchez, J. L.; Sala, J.

    2000-01-01

    We present a fatal case of intracranial air embolism produced by the passage of intravenous air to the arteries owing to the existence of a patent foremen ovale associated with pulmonary hypertension, which permitted a right-left shunt (paradoxical embolism). The pathophysiological mechanisms of pneumcephalus and paradoxical embolism are discussed and the pertinent literature is reviewed. (Author) 6 refs

  9. Dioxin in Danish air

    Energy Technology Data Exchange (ETDEWEB)

    Vikelsoe, J.; Andersen, H.V. [National Environmental Research Inst., Roskilde (Denmark)

    2004-09-15

    To gain more knowledge about dioxin levels, sources and emissions in Denmark, the Danish government year 2001 initiated the Danish Dioxin Monitoring Program. The program is a series of investigations, comprising soil, compost, percolate, bio-ash, incineration of municipal and hazardous waste, deposition, air, lake and fjord sediment as well as cows milk and human milk. The present paper describes the preliminary results for the continued investigation of air. Deposition of dioxin over land or sea is of major importance for the human exposure, which takes place mainly from food intake. The dioxin are emitted mainly to the atmosphere, therefore air measurements are well suited for tracking the transport and fate of dioxin from sources to exposure. Whereas measurements from chimneys has been frequently used to estimate the industrial emission from point sources such as incinerators, air measurements also include emission from diffuse sources such as larger urban or industrial regions, residential quarters, and from evaporation. Furthermore, emission measurements must be done on known sources, whereas air measurements include contribution from unknown source. The major drawbacks of air measurements are the long duration required (years), and the results depends on meteorological conditions, such as temperature, rainfall, wind speed and direction. The purpose of the present study has been to measure dioxins in Danish air, emphasizing - background concentrations and annual variation - difference between urban, rural and residential zones - influence from local sources and long range transport - connection between dioxin in air and deposition.

  10. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  11. Air Pollution and Industry.

    Science.gov (United States)

    Ross, R. D., Ed.

    This book is an authoritative reference and practical guide designed to help the plant engineer identify and solve industrial air pollution problems in order to be able to meet current air pollution regulations. Prepared under the editorial supervision of an experienced chemical engineer, with each chapter contributed by an expert in his field,…

  12. Transportation and air quality

    International Nuclear Information System (INIS)

    Roseland, M.

    1992-01-01

    In the greater Vancouver regional district (GVRD), some 80% of the annual production of 600,000 tonnes of air pollutants come from motor vehicles. Three critical air quality issues in the GVRD are discussed: local air pollution, ozone layer depletion, and greenhouse gas emissions, all of which are fundamentally linked to transportation. Overall air quality in the GVRD has been judged acceptable by current federal standards, but ground-level ozone has exceeded maximum tolerable levels at some locations and concentrations of suspended particulates are above maximum acceptable levels. Serious deterioration in air quality has been predicted unless a concerted effort is made to manage air quality on an airshed-wide basis. The GVRD is developing Canada's first Air Management Plan with the goal of halving atmospheric emissions by 2000. GVRD transportation priorities stress public transit, walking, cycling, car pooling, and reducing of travel demand; however, the viability of such strategies depends on decisions made outside the transportation sector. Restricted authority and jurisdiction also hinder GVRD goals; the regional level of government has no authority over highways or transit and only has authority for pollution control in some parts of the Fraser Valley. Airshed quality management, using the Los Angeles example, is seen as a possible direction for future GVRD policymaking in the transportation sector. A single regional planning agency with responsibility for transportation, land use, and air quality management appears as the best option for an integrated approach to solve multiple problems. 19 refs

  13. Over the air test

    DEFF Research Database (Denmark)

    2015-01-01

    [1] This invention relates to over-the-air testing of a device in an anechoic chamber. In particular, the invention is suitable for simulating both uplink and downlink over-the-air communication with a device under test even when the anechoic chamber has different numbers of uplink and downlink...

  14. Recirculating electric air filter

    Science.gov (United States)

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  15. Air Pollution Primer.

    Science.gov (United States)

    National Tuberculosis and Respiratory Disease Association, New York, NY.

    As the dangers of polluted air to the health and welfare of all individuals became increasingly evident and as the complexity of the causes made responsibility for solutions even more difficult to fix, the National Tuberculosis and Respiratory Disease Association felt obligated to give greater emphasis to its clean air program. To this end they…

  16. Air Force Senior Leaders

    Science.gov (United States)

    Force TV Radio Week in Photos About Us Air Force Senior Leaders SECAF CSAF CMSAF Biographies Adjunct Professors Senior Mentor Biographies Fact Sheets Commander's Call Topics CCT Archive CSAF Reading List 2017 Media Sites Site Registration Contact Us Search AF.mil: Home > About Us > Air Force Senior Leaders

  17. Air Layer Drag Reduction

    Science.gov (United States)

    Ceccio, Steven; Elbing, Brian; Winkel, Eric; Dowling, David; Perlin, Marc

    2008-11-01

    A set of experiments have been conducted at the US Navy's Large Cavitation Channel to investigate skin-friction drag reduction with the injection of air into a high Reynolds number turbulent boundary layer. Testing was performed on a 12.9 m long flat-plate test model with the surface hydraulically smooth and fully rough at downstream-distance-based Reynolds numbers to 220 million and at speeds to 20 m/s. Local skin-friction, near-wall bulk void fraction, and near-wall bubble imaging were monitored along the length of the model. The instrument suite was used to access the requirements necessary to achieve air layer drag reduction (ALDR). Injection of air over a wide range of air fluxes showed that three drag reduction regimes exist when injecting air; (1) bubble drag reduction that has poor downstream persistence, (2) a transitional regime with a steep rise in drag reduction, and (3) ALDR regime where the drag reduction plateaus at 90% ± 10% over the entire model length with large void fractions in the near-wall region. These investigations revealed several requirements for ALDR including; sufficient volumetric air fluxes that increase approximately with the square of the free-stream speed, slightly higher air fluxes are needed when the surface tension is reduced, higher air fluxes are required for rough surfaces, and the formation of ALDR is sensitive to the inlet condition.

  18. Restoran Buenos Aires = Restaurant Buenos Aires

    Index Scriptorium Estoniae

    2008-01-01

    Restorani Buenos Aires (Narva mnt. 5, Tallinn) sisekujundusest. Sisearhitektid: Janno Roos ja Andres Labi (Ruumilabor OÜ). Laudu eraldavad 400 vardasse aetud puukuuli. Sisearhitektidest, nende tähtsamad tööd. I-III korruse plaan, 12 värv. vaadet, fotod sisearhitektidest

  19. Implementation and responsibility for waste disposal : AEC sets up frameworks

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The Atomic Energy Commission approved the report ''measures for treatment and disposal of radioactive waste'' made by its advisory committee; which clarifies where the legal responsibility lies in relation to the waste treatment and disposal. In principle, the waste producers, i.e. the electric power companies should be responsible for the treatment and disposal of low-level radioactive waste and the Government for regulation of the safety of waste management. Then, in connection with a LLW ultimate storage facility planned in Aomori Prefecture, the waste disposal company may be responsible for safety of the LLW management. The disposal of high-level radioactive waste is the responsibility of the Government, the waste producer being responsible for the cost. Contents are the following: organization and responsibility for treatment and disposal of radioactive waste; concept of disposal of TRU waste. (Mori, K.)

  20. The French AEC nuclear microprobe: description and first application examples

    International Nuclear Information System (INIS)

    Engelmann, C.; Bardy, J.

    1983-05-01

    The major components of the microprobe are briefly described. The performances and the varying possibilities authorized by the instrument are given. Some application examples concerning especially the determination of concentration profiles in an aqueous leached glass and the distribution of deuterium in a graphite sample exposed to plasma in a Tokamak device are presented

  1. Expert System Techniques and Applications in AEC-Design

    DEFF Research Database (Denmark)

    Andersen, Tom

    This part of a book presents expert system techniques applicable to building design and construction, and it reports and evaluates on systems developed in thar domain.......This part of a book presents expert system techniques applicable to building design and construction, and it reports and evaluates on systems developed in thar domain....

  2. A/E/C CAD Standard, Release 5.0

    Science.gov (United States)

    2012-12-01

    DMPR Dampers 0 0.35 22 22 X X Graphic Defaults Model File Types CO2 Sprinkler System Aqueous Film Forming Foam System Means of Egress Lighting...45 X E-POWR- GENR Generators and auxiliary equipment 0 0.50 4 7 X E-POWR-JBOX Junction boxes, pull boxes, manholes, handholes, pedestals, splices 0

  3. Nuclear Research and Development in the AEC Era

    International Nuclear Information System (INIS)

    Mongkolnavin, R.

    2014-01-01

    In 2015, South East Asian Countris are entering into the social, economic and security partnership. Nuclear Research and Development undoubtedly has important roles in all three pillars. Nuclear applications that are being realised in the region ranges from energy, mrdical to agricultural application.In this new era of cooperation, we are seeking for technologies that lead to solution to improve our ways of living. As all other research and development nuclear research has been carried out in all countries in the region. However, it does have its critiques on safety issues based on people capability in the region. In order to make progress in research and development, human resource development is the key fundamental to its sucess. An experience of regional collaboration in developing pulsed neutron souurce is presented as an example. The research had been revived though collaoration of different research laboratories within ASEAN countries with support of Asian African Assosiation for Plasma Training (AAAPT). The 'low cost research theme' has fundamentally set up a platform for more future advanced research for fusion and for local industrial applications. It also increases experimental and theoretical research awareness among new generations that could be carried out in local laboratories. A device such as UNU-ICPT Plasma Focus has been explored, and it has been built, studied; both theoretical and experimental; and used for many different kind of applications.

  4. A/E/C CAD Standard, Release 4.0

    Science.gov (United States)

    2009-07-01

    Bath .....................D8-23 BATHEM – Emergency Bath .............D8-23 BATHFT – Foot Bath..........................D8-23 BATHHA – Hydrotherapy ...Arm Bath .D8-23 BATHHH – Hydrotherapy Hubbard Bath................................D8-23 BATHHL – Hydrotherapy Leg Bath...D8-23 BATHIF – Infant

  5. The French A.E.C. nuclear robotic program

    International Nuclear Information System (INIS)

    Foult, T.

    1991-01-01

    The new French nuclear robotic program launched by the CEA was started at the beginning of 1988 for the duration of two years and with the total subsidy of about 130 million French franc. This program includes the following four steps: the definition of model missions dedicated to inspection and intervention in nuclear environment, the system analysis to define the systems, functions and specifications required to perform these model missions, the technological development required to achieve these systems, and the design of demonstration models with the partial integration of the above developments. The whole program including these four steps is called SYROCO (modular SYstem for RObots COoperating in radioactive environment). The repair of leak in a pipe in a reprocessing cell, the model mission in a PWR nuclear power plant, autonomous load bearing mobile robots, squirrel concept light modular carrier concept, radiation hardening, mechanic, perception of environment, communication, control and simulation and the demonstration models are described. SHERPA project, perception management, force controlled manipulator, squirrel project, light modular carrier, processes and NAB model mission simulation are particularly mentioned

  6. Air Baltic: Estonian Air on nurka surutud / Teele Tammeorg

    Index Scriptorium Estoniae

    Tammeorg, Teele

    2010-01-01

    Air Balticu asepresidendi Janis Vanagsi hinnangul on Estonian Air aastaid jätnud tähelepanuta oma peamised turismiturud ning on praegu halvas seisus. Air Baltic on endiselt huvitatud Estonian Airi ostust. Majandus- ja kommunikatsiooniminister Juhan Partsi seisukoht

  7. Air ejector augmented compressed air energy storage system

    Science.gov (United States)

    Ahrens, F.W.; Kartsounes, G.T.

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air presure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  8. Controlled air incineration

    International Nuclear Information System (INIS)

    Seitz, K.A.

    1991-01-01

    From 1960 to 1970, incineration was recognized as an economical method of solid waste disposal with many incinerators in operation through the country. During this period a number of legislation acts began to influence the solid waste disposal industry, namely, the Solid Waste Disposal Act of 1965; Resource Conservation Recovery Act (RCRA) of 1968; Resource Recovery Act of 1970; and Clean Air Act of 1970. This period of increased environmental awareness and newly created regulations began the closure of many excess air incineration facilities and encouraged the development of new controlled air, also known as Starved-Air incinerator systems which could meet the more stringent air emission standards without additional emission control equipment. The Starved-Air technology initially received little recognition because it was considered unproven and radically different from the established and accepted I.I.A. standards. However, there have been many improvements and developments in the starved-air incineration systems since the technology was first introduced and marketed, and now these systems are considered the proven technology standard

  9. Air Pollution and Stroke.

    Science.gov (United States)

    Lee, Kuan Ken; Miller, Mark R; Shah, Anoop S V

    2018-01-01

    The adverse health effects of air pollution have long been recognised; however, there is less awareness that the majority of the morbidity and mortality caused by air pollution is due to its effects on the cardiovascular system. Evidence from epidemiological studies have demonstrated a strong association between air pollution and cardiovascular diseases including stroke. Although the relative risk is small at an individual level, the ubiquitous nature of exposure to air pollution means that the absolute risk at a population level is on a par with "traditional" risk factors for cardiovascular disease. Of particular concern are findings that the strength of this association is stronger in low and middle income countries where air pollution is projected to rise as a result of rapid industrialisation. The underlying biological mechanisms through which air pollutants exert their effect on the vasculature are still an area of intense discussion. A greater understanding of the effect size and mechanisms is necessary to develop effective strategies at individual and policy levels to mitigate the adverse cardiovascular effects of air pollution.

  10. Air Quality Guide for Ozone

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Air Quality Guide for Ozone Ground-level ozone is one of our nation’s most common air pollutants. Use the chart below to help reduce ...

  11. Emission Facilities - Air Emission Plants

    Data.gov (United States)

    NSGIC Education | GIS Inventory — Represents the Primary Facility type Air Emission Plant (AEP) point features. Air Emissions Plant is a DEP primary facility type related to the Air Quality Program....

  12. Agriculture: Agriculture and Air Quality

    Science.gov (United States)

    Information on air emissions from agricultural practices, types of agricultural burning, air programs that may apply to agriculture, reporting requirements, and links to state and other federal air-quality information.

  13. Lean in Air Permitting Guide

    Science.gov (United States)

    The Lean in Air Permitting Guide is designed to help air program managers at public agencies better understand the potential value and results that can be achieved by applying Lean improvement methods to air permitting processes.

  14. Ambient Air Quality Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Office of Air and Radiation's (OAR) Ambient Air Quality Data (Current) contains ambient air pollution data collected by EPA, other federal agencies, as well as...

  15. Air Quality Management Process Cycle

    Science.gov (United States)

    Air quality management are activities a regulatory authority undertakes to protect human health and the environment from the harmful effects of air pollution. The process of managing air quality can be illustrated as a cycle of inter-related elements.

  16. Ozone - Current Air Quality Index

    Science.gov (United States)

    GO! Local Air Quality Conditions Zip Code: State : My Current Location Current AQI Forecast AQI Loop More Maps AQI: Good (0 - 50) ... resources for Hawaii residents and visitors more announcements Air Quality Basics Air Quality Index | Ozone | Particle Pollution | Smoke ...

  17. Clean Air Act Amendments of 1990: Impacts on natural gas markets. Summary of the annual GRI Energy Seminar (12th) for the GRI Board of Directors and Advisory Council. Held in Asheville, North Carolina on August 12-14, 1991

    International Nuclear Information System (INIS)

    Farrell, M.D.

    1991-01-01

    Each year, Gas Research Institute (GRI) conducts an energy seminar for its Board of Directors and Advisory Council on an issue of timely importance to the gas industry. The topic selected for the Twelfth Annual GRI Energy Seminar was 'Clean Air Act Amendments of 1990: Impacts on Natural Gas Markets.' The two sessions of the seminar focused upon the sectors of the energy market most significantly affected by the legislation. Session I: Fuel Choices for Stationary Applications explored the impact of the Clean Air Act Amendments upon stationary, fuel-burning applications, particularly power plants. The current outlook for bringing existing coal-fired power plants into conformance with the law and the significance of the provisions for the choice of fuels for major future fuel-burning facilities were discussed, along with the impact of the provisions upon GRI's strategies and the technical and economic targets for ongoing R and D. Session II: The Emerging Alternative-Fuel Vehicle Market addressed the significance of the new requirements to the outlook for compressed natural gas vehicles and the suitability of GRI's methane vehicle R and D strategy to the revised outlook. The report summarizes the presentations and discussions at the seminar

  18. Air/Water Purification

    Science.gov (United States)

    1992-01-01

    After 18 years of research into air/water pollution at Stennis Space Center, Dr. B. C. Wolverton formed his own company, Wolverton Environmental Services, Inc., to provide technology and consultation in air and water treatment. Common houseplants are used to absorb potentially harmful materials from bathrooms and kitchens. The plants are fertilized, air is purified, and wastewater is converted to clean water. More than 100 U.S. communities have adopted Wolverton's earlier water hyacinth and artificial marsh applications. Catfish farmers are currently evaluating the artificial marsh technology as a purification system.

  19. Appendicitis with Intraluminal Air

    International Nuclear Information System (INIS)

    Fernandez, Alfredo; Ramirez, Sandra M; Rodriguez, Cesar A; Uriza, Luis F

    2010-01-01

    The presentation of acute appendicitis with intraluminal air is an uncommon presentation. Ultrasound is a widely used and accepted to establish the diagnosis of appendicitis, but its performance is limited in situations where there is interposition of air. Inflamed appendix which presents with distension by gas can be source of error in ultrasound to establish a false negative diagnosis. In this article we present three patients with appendicitis where the interposition of intraluminal air hid their diagnostic by ultrasound. In all three cases the definitive diagnosis was established by computed tomography and surgical confirmation.

  20. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  1. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The air quality in Danish cities has been monitored continuously since 1982 within the Danish Air Quality (LMP) network. The aim has been to follow the concentration levels of toxic pollutants in the urban atmosphere and to provide the necessary knowledge to assess the trends, to perform source...... apportionment, and to evaluate the chemical reactions and the dispersion of the pollutants in the atmosphere. In 2002 the air quality was measured in four Danish cities and at two background sites. NO2 and PM10 were at several stations found in concentrations above the new EU limit values, which the Member...

  2. Olefin metathesis in air

    Directory of Open Access Journals (Sweden)

    Lorenzo Piola

    2015-10-01

    Full Text Available Since the discovery and now widespread use of olefin metathesis, the evolution of metathesis catalysts towards air stability has become an area of significant interest. In this fascinating area of study, beginning with early systems making use of high oxidation state early transition metal centers that required strict exclusion of water and air, advances have been made to render catalysts more stable and yet more functional group tolerant. This review summarizes the major developments concerning catalytic systems directed towards water and air tolerance.

  3. Air/liquid collectors

    DEFF Research Database (Denmark)

    Jensen, Søren Østergaard; Olesen, Ole; Kristiansen, Finn Harken

    1997-01-01

    this kind of collectors. The modified simulation program has been used for the determination of the surplus in performance which solar heating systems with this type of solar collectors for combined preheating of ventilation air and domestic hot water will have. The simulation program and the efficiency......This report determine efficiency equations for combined air/liquid solar collectors by measurements on to different air/liquid collectors. Equations which contain all relevant informations on the solar collectors. A simulation program (Kviksol) has been modified in order to be able to handle...

  4. Air tight electrical box

    Energy Technology Data Exchange (ETDEWEB)

    Pringle, C.G.

    1990-08-14

    An air-impervious electrical box to facilitate air sealing a house comprises an integral, rigid box body having a continuous flange, integral with the body, circumscribing and outwardly extending from the sides of the body. This flange is rearwardly positioned behind the front edges of the sides of the body a predetermined distance so that the electrical box may be secured to framing by nailing through the flange. Drywall is then secured to the frame on top of and adjecent to the flange. Such box eliminates the necessity for solid backing and minimizes passage of air through the box and space between the drywall and the box.

  5. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    2007-04-10

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.  Created: 4/10/2007 by CDC National Center for Environmental Health.   Date Released: 4/13/2007.

  6. Air-Inflated Fabric Structures

    National Research Council Canada - National Science Library

    Cavallaro, Paul V; Sadegh, Ali M

    2006-01-01

    .... Examples include air ships, weather balloons, inflatable antennas and radomes, temporary shelters, pneumatic muscles and actuators, inflatable boats, temporary bridging, and energy absorbers such as automotive air bags...

  7. Introduction to Indoor Air Quality

    Science.gov (United States)

    ... Offices Regional Offices Labs and Research Centers Indoor Air Quality (IAQ) Contact Us Share Introduction to Indoor Air Quality Health Effects Primary Causes Identifying Problems Improving IAQ ...

  8. Organisation of biological research carried out in the United States by the A.E.C. or under her contract (1960); Organisation des recherches biologiques menees aux Etats-Unis par l'A.E.C. ou sous son egide. Compte-rendu sommaire d'une mission d'etude (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Pellerin, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    This report is based on information gathered in the course of a trip to the United States, in November and December 1958 which consisted chiefly of visits to the main biological and medical research laboratories and discussions with the heads of these establishments. A description is given of the general organisation of the Atomic Energy Commission's Division of Biology and Medicine, and of the distribution of responsibility for radiation protection work and for biological, medical and agricultural research amongst the various Services attached to it; this is followed by a more detailed account of the activities carried on in this field at the great national laboratories. Finally, the systems of collaboration set up with external research organisations in the form of research contracts are examined, together with the substantial help provided by the A.E.C. for biological, medical and agricultural research in general, owing to a systematic policy of subsidising the distribution of radioisotopes for this purpose. (author) [French] Le present rapport a ete etabli sur la base des renseignements recueillis au cours d'un voyage d'etude aux Etats-Unis, en novembre et decembre 1958, comportant notamment la visite des principaux laboratoires de recherche biologique et medicale et des entretiens avec les principaux responsables de ces laboratoires. Apres une description de l'organisation generale de la 'Division of Biology and Medicine' de l'Atomic Energy Commission et de la repartition entre les divers Services qui lui sont rattaches des responsabilites concernant la protection contre les radiations et la Recherche biologique, medicale et agronomique, des indications plus detaillees sont donnees au sujet des activites poursuivies dans ce domaine au sein des grands laboratoires nationaux. Sont examinees enfin, l'importance et les modalites de la collaboration instituee avec les Organismes de Recherche exterieurs sous la forme de contrats de recherche ainsi que l

  9. Organisation of biological research carried out in the United States by the A.E.C. or under her contract (1960); Organisation des recherches biologiques menees aux Etats-Unis par l'A.E.C. ou sous son egide. Compte-rendu sommaire d'une mission d'etude (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Pellerin, J. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    This report is based on information gathered in the course of a trip to the United States, in November and December 1958 which consisted chiefly of visits to the main biological and medical research laboratories and discussions with the heads of these establishments. A description is given of the general organisation of the Atomic Energy Commission's Division of Biology and Medicine, and of the distribution of responsibility for radiation protection work and for biological, medical and agricultural research amongst the various Services attached to it; this is followed by a more detailed account of the activities carried on in this field at the great national laboratories. Finally, the systems of collaboration set up with external research organisations in the form of research contracts are examined, together with the substantial help provided by the A.E.C. for biological, medical and agricultural research in general, owing to a systematic policy of subsidising the distribution of radioisotopes for this purpose. (author) [French] Le present rapport a ete etabli sur la base des renseignements recueillis au cours d'un voyage d'etude aux Etats-Unis, en novembre et decembre 1958, comportant notamment la visite des principaux laboratoires de recherche biologique et medicale et des entretiens avec les principaux responsables de ces laboratoires. Apres une description de l'organisation generale de la 'Division of Biology and Medicine' de l'Atomic Energy Commission et de la repartition entre les divers Services qui lui sont rattaches des responsabilites concernant la protection contre les radiations et la Recherche biologique, medicale et agronomique, des indications plus detaillees sont donnees au sujet des activites poursuivies dans ce domaine au sein des grands laboratoires nationaux. Sont examinees enfin, l'importance et les modalites de la collaboration instituee avec les Organismes de Recherche exterieurs sous la forme de

  10. Regional Air Quality Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset provides data on regional air quality, including trace level SO2, nitric acid, ozone, carbon monoxide, and NOy; and particulate sulfate, nitrate, and...

  11. Healthy Air Outdoors

    Science.gov (United States)

    ... a few sources. Even natural sources such as fires and dust contribute to air pollution. Learn more ... Walks Cycling Events Donate a Car Memorial & Honor Gifts Planned Giving Christmas Seals ABOUT THE LUNG ASSOCIATION ...

  12. Air Data Calibration Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is for low altitude subsonic altimeter system calibrations of air vehicles. Mission is a direct support of the AFFTC mission. Postflight data merge is...

  13. Air Travel Health Tips

    Science.gov (United States)

    ... if you touch anything in your seat back pocket. The air pressure in the plane can change ... counter Products Procedures & Devices Prescription Medicines Health Tools Dictionary Symptom Checker BMI Calculator myhealthfinder Immunization Schedules Nutrient ...

  14. Hanscom Air Force Base

    Data.gov (United States)

    Federal Laboratory Consortium — MIT Lincoln Laboratory occupies 75 acres (20 acres of which are MIT property) on the eastern perimeter of Hanscom Air Force Base, which is at the nexus of Lexington,...

  15. Improving Indoor Air Quality

    Science.gov (United States)

    Usually the most effective way to improve indoor air quality is to eliminate individual sources of pollution or to reduce their emissions. Some sources, like those that contain asbestos, can be sealed or enclosed.

  16. State Air Quality Standards.

    Science.gov (United States)

    Pollution Engineering, 1978

    1978-01-01

    This article presents in tabular form the air quality standards for sulfur dioxide, carbon monoxide, nitrogen dioxide, photochemicals, non-methane hydrocarbons and particulates for each of the 50 states and the District of Columbia. (CS)

  17. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  18. Operational air sampling report

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products

  19. Advanced air distribution

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2011-01-01

    The aim of total volume air distribution (TVAD) involves achieving uniform temperature and velocity in the occupied zone and environment designed for an average occupant. The supply of large amounts of clean and cool air are needed to maintain temperature and pollution concentration at acceptable...... levels in the entire space, leading to increased energy consumption and the use of large and costly HVAC and duct systems. The performance of desk installed PV combined with background TVAD used for room temperature control has been studied in an office building located in a hot and humid climate....... Ventilation in hospitals is essential to decrease the risk of airborne cross-infection. At present, mixing air distribution at a minimum of 12 ach is used in infection wards. Advanced air distribution has the potential to aid in achieving healthy, comfortable and productive indoor environments at levels...

  20. Air conditioning system

    Science.gov (United States)

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  1. Calidad del aire interior

    Science.gov (United States)

    This web site will educate the public about indoor environmental issues including health risks and means by which human exposures can be reduced. Content on this site will be focused on Spanish translated resources for information about indoor air quality.

  2. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  3. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  4. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  5. Process air quality data

    Science.gov (United States)

    Butler, C. M.; Hogge, J. E.

    1978-01-01

    Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.

  6. Air void clustering.

    Science.gov (United States)

    2015-06-01

    Air void clustering around coarse aggregate in concrete has been identified as a potential source of : low strengths in concrete mixes by several Departments of Transportation around the country. Research was : carried out to (1) develop a quantitati...

  7. Air Distribution in Rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The research on air distribution in rooms is often done as full-size investigations, scale-model investigations or by Computational Fluid Dynamics (CFD). New activities have taken place within all three areas and this paper draws comparisons between the different methods. The outcome of the l......EA sponsored research "Air Flow Pattern within Buildings" is used for comparisons in some parts of the paper because various types of experiments and many countries are involved....

  8. Indoor Air Pollution

    OpenAIRE

    Kirk R. Smith

    2003-01-01

    Outdoor air pollution in developing-country cities is difficult to overlook. Indoor air pollution caused by burning such traditional fuels as wood, crop residues, and dung is less evident, yet it is responsible for a significant part of country and global disease burdens. The main groups affected are poor women and children in rural areas and urban slums as they go about their daily activi...

  9. INDOOR AIR POLLUTION

    OpenAIRE

    Ahmet Soysal; Yucel Demiral

    2007-01-01

    The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas...

  10. Canada's Clean Air Act

    International Nuclear Information System (INIS)

    2006-01-01

    This paper provided an outline of Canada's Clean Air Act and examined some of the regulatory changes that will occur as a result of its implementation. The Act is being introduced to strengthen the legislative basis for taking action on reducing air pollution and GHGs, and will allow the government to regulate both indoor and outdoor air pollutants and GHGs. The Act will require the Ministers of the Environment and Health to establish national air quality objectives, as well as to monitor and report on their attainment. The Canadian Environmental Protection Act will be amended to enable the government to regulate the blending of fuels and their components. The Motor Vehicle Fuel Consumption Standards Act will also be amended to enhance the government's authority to regulate vehicle fuel efficiency. The Energy Efficiency Act will also be expanded to allow the government to set energy efficiency standards and labelling requirements for a wider range of consumer and commercial products. The Act will commit to short, medium and long-term industrial air pollution targets. Regulations will be proposed for emissions from industry; on-road and off-road vehicles and engines; and consumer and commercial products. It was concluded that the Government of Canada will continue to consult with provinces, territories, industries and Canadians to set and reach targets for the reduction of both indoor and outdoor air pollutants and GHG emissions. 6 figs

  11. The urban air; L'air de la ville

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This paper presents the abstracts of conferences proposed during the meeting on the urban air, organized by the French Meteorological Society in november 2002. These conferences dealt with the air quality monitoring, the public health impacts, the air pollution in function of the meteorological effects, the pollutants, the main factors of the air quality and the models of the meteorology. (A.L.B.)

  12. 78 FR 15895 - Approval and Promulgation of Air Quality Implementation Plans: North Carolina; Control Techniques...

    Science.gov (United States)

    2013-03-13

    ... Requirements and Open Burning and are not required to meet RACT for the 1997 8-hour ozone standard. b. Summary... 90 percent overall control. Twelfth, Rule 15A NCAC 02D .0967, ``Miscellaneous Metal and Plastic Parts Coatings'' was adopted to control VOC emissions from miscellaneous metal and plastic part surface coatings...

  13. Selection of Air Terminal Device

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,......This paper discusses the selection of the air terminal device for the experiments and numerical prediction in the International Energy Agency Annex 20 work: Air Flow Pattern within Buildings,...

  14. Infants Can Study Air Science.

    Science.gov (United States)

    Ward, Alan

    1983-01-01

    Provided are activities and demonstrations which can be used to teach infants about the nature of air, uses of air, and objects that fly in the air. The latter include airships, hot-air balloons, kites, parachutes, airplanes, and Hovercraft. (JN)

  15. Indoor air pollution

    International Nuclear Information System (INIS)

    Anwar, J.; Hussain, F.

    2005-01-01

    Indoor air pollution after being a neglected subject for a number of years, is attracting attention recently because it is a side effect of energy crisis. About 50% of world's 6 billion population, mostly in developing countries, depend on biomass and coal in the form of wood, dung and crop residues for domestic energy because of poverty. These materials are burnt in simple stoves with incomplete combustion and infants, children and women are exposed to high levels of indoor air pollution for a considerable period, approximately between 2-4 hours daily. Current worldwide trade in wood fuel is over US $7 billion and about 2 million people are employed full time in production and marketing it. One of the most annoying and common indoor pollutant in both, developing and developed countries, is cigarette smoke. Children in gas-equipped homes had higher incidences of respiratory disease. Babies' DNA can be damaged even before they are born if their mothers breathe polluted air. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for 4% of the global burden of the disease. Only a few indoor pollutants have been studied in detail. Indoor air pollution is a major health threat on which further research is needed to define the extent of the problem more precisely and to determine solutions by the policy-makers instead of neglecting it because sufferers mostly belong to Third World countries. (author)

  16. Advanced air detritiation dryer

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The isotopic exchange principle has proved effective in increasing air detritiation factors of atmospheric dryers. A CFFTP/AECL Chalk River program has demonstrated detritiation factors of 100,000 in trials. The technology is designed for application on regenerating atmospheric dryers using molecular sieve desiccant beds, used in rooms likely to encounter airborne tritium contamination. Dryer design concepts for dryers at JET (Joint European Torus, England) and ITER have been prepared by Alan Dombra of AECL, using the isotopic exchange technology. The isotopic exchange method works by passing tritiated air over a detritiated desiccant bed. Airborne tritium atoms are exchanged in the bed for ordinary hydrogen atoms from the bed's residual moisture loading. Tritium remains on the bed until it is discharged in a regeneration cycle. During regeneration, the desiccant bed is first heated with hot, dry air to drive off collected tritiated moisture. Airborne tritium removed from the air is collected as a tritiated water distillate and stored for later processing. During the second part of the regeneration cycle, the desiccant bed is washed with clean moist air to elute remaining traces of tritium and to refresh the bed to ready it for another tritium absorption period

  17. Compressed air energy storage system

    Science.gov (United States)

    Ahrens, Frederick W.; Kartsounes, George T.

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  18. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull 2007; 6(3.000: 221-226

  19. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull. 2007; 6(3: 221-226

  20. Air pollution and vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Numata, M

    1975-01-01

    Although the direct effects of each air pollutant have been fairly well studied for specific species of plants used as indicators, studies on the synecological level have not been done. Clement's communities can be used as indicators. The effects of air pollution should be studied as one in a complex of factors. The characteristic features of biological indicators are described in detail with emphasis on applying the results to human beings in polluted environments. The methods of determining the effects of pollution are described, using a community phytometer and remote sensing methods. Directly connecting the level of air pollution to the wilting of trees in general is dangerous unless it is a matter of an acute episode.

  1. Air-Sea Interaction

    Science.gov (United States)

    Csanady, G. T.

    2001-03-01

    In recent years air-sea interaction has emerged as a subject in its own right, encompassing small-scale and large-scale processes in both air and sea. Air-Sea Interaction: Laws and Mechanisms is a comprehensive account of how the atmosphere and the ocean interact to control the global climate, what physical laws govern this interaction, and its prominent mechanisms. The topics covered range from evaporation in the oceans, to hurricanes, and on to poleward heat transport by the oceans. By developing the subject from basic physical (thermodynamic) principles, the book is accessible to graduate students and research scientists in meteorology, oceanography, and environmental engineering. It will also be of interest to the broader physics community involved in the treatment of transfer laws, and thermodynamics of the atmosphere and ocean.

  2. The Clean Air Act

    International Nuclear Information System (INIS)

    Coburn, L.L.

    1990-01-01

    The Clean Air Act amendments alter the complex laws affecting atmospheric pollution and at the same time have broad implications for energy. Specifically, the Clean Air Act amendments for the first time deal with the environmental problem of acid deposition in a way that minimizes energy and economic impacts. By relying upon a market-based system of emission trading, a least cost solution will be used to reduce sulfur dioxide (SO 2 ) emissions by almost 40 percent. The emission trading system is the centerpiece of the Clean Air Act (CAA) amendments effort to resolve energy and environmental interactions in a manner that will maximize environmental solutions while minimizing energy impacts. This paper will explore how the present CAA amendments deal with the emission trading system and the likely impact of the emission trading system and the CAA amendments upon the electric power industry

  3. Unit for air decontamination

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-02-01

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  4. Air quality risk management.

    Science.gov (United States)

    Williams, Martin L

    2008-01-01

    Rather than attempt to provide a comprehensive account of air quality risk assessment, as might be found in a textbook or manual, this article discusses some issues that are of current importance in the United Kingdom and the rest of Europe, with special emphasis on risk assessment in the context of policy formulation, and emerging scientific knowledge. There are two pollutants of particular concern and that both pose challenges for risk assessment and policy, and they are particulate matter (PM) and ozone. The article describes some issues for health risk assessment and finally some forward-looking suggestions for future approaches to air quality management.

  5. Liquid air cycle engines

    Science.gov (United States)

    Rosevear, Jerry

    1992-01-01

    Given here is a definition of Liquid Air Cycle Engines (LACE) and existing relevant technologies. Heat exchanger design and fabrication techniques, the handling of liquid hydrogen to achieve the greatest heat sink capabilities, and air decontamination to prevent heat exchanger fouling are discussed. It was concluded that technology needs to be extended in the areas of design and fabrication of heat exchangers to improve reliability along with weight and volume reductions. Catalysts need to be improved so that conversion can be achieved with lower quantities and lower volumes. Packaging studies need to be investigated both analytically and experimentally. Recycling with slush hydrogen needs further evaluation with experimental testing.

  6. Air the excellent canopy

    CERN Document Server

    Fahy, F

    2013-01-01

    We take it for granted, but without it we perish and if we continue to abuse it, it may kill us in the end. This fascinating text provides an understanding and appreciation of the role that air plays in our environment and its importance in relation to human life and technology. Aimed at those who are scientifically curious but who have no specialist training, it contains no mathematical equations and relies upon the qualitative descriptions and analogies to explain the more technical parts of the text together with simple home experiments to illustrate a range of air-based phenomena. Liberall

  7. Air condensation plants

    International Nuclear Information System (INIS)

    Kelp, F.; Pohl, H.H.

    1978-01-01

    In this plant the steam is distributed by a ventilator from the bottom to symmetrically fixed, inclined cooling elements with tubes. The upper part of the current side of the cooling elements as well as the bottom part of the outflow side can be covered by cover plates via a control circuit. This way, part of the air amount is deviated and in case of unfavourable atmospheric conditions (cold) the air is heated. This heating is enough to prevent freezing of the condensate on the cooling tubes. (DG) [de

  8. Automatic programmable air ozonizer

    International Nuclear Information System (INIS)

    Gubarev, S.P.; Klosovsky, A.V.; Opaleva, G.P.; Taran, V.S.; Zolototrubova, M.I.

    2015-01-01

    In this paper we describe a compact, economical, easy to manage auto air ozonator developed at the Institute of Plasma Physics of the NSC KIPT. It is designed for sanitation, disinfection of premises and cleaning the air from foreign odors. A distinctive feature of the developed device is the generation of a given concentration of ozone, approximately 0.7 maximum allowable concentration (MAC), and automatic maintenance of a specified level. This allows people to be inside the processed premises during operation. The microprocessor controller to control the operation of the ozonator was developed

  9. Proceedings of the twelfth target fabrication specialists` meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-04-01

    Research in fabrication for inertial confinement fusion (ICF) comprises at least three broad categories: targets for high energy density physics on existing drivers, ignition capsule fabrication, and cryogenic fuel layer formation. The latter two are being pursued primarily for the National Ignition Facility (NIF). Scientists from over 14 laboratories, universities, and businesses contributed over 100 papers on all aspects of ICF target fabrication. The NIF is well along in construction and photos of poured concrete and exposed steel added to the technical excitement. It was clear from the meeting that there has been significant progress toward the fabrication of an ignition target for NIF and that new techniques are resulting in higher quality targets for high energy density research.

  10. Proceedings of the twelfth annual conference on fossil energy materials

    International Nuclear Information System (INIS)

    Judkins, R.R.

    1998-01-01

    Papers are presented under the following session headings: ceramic composites and functional materials; ceramics, new alloys and functional materials; summary report on the workshop on materials for separation process for Vision 21 systems; and new alloys. A list of attendees is included

  11. Stratus 12 Twelfth Setting of the Stratus Ocean Reference Station

    Science.gov (United States)

    2012-10-01

    to bottom sea floor. Last visual on S12. Short bathymetry survey. Watches resume for drifters launches and UCTD, with feedback from bridge prior to... pendant was shackled to that chain, and another 5-meter section of ½” chain was shackled to the anchor pendant . The mooring winch wound up these

  12. Twelfth meeting of the ITER physics expert group on diagnostics

    International Nuclear Information System (INIS)

    Costley, A.E.; Donne, A.J.H.

    2000-01-01

    The main technical objectives of the meeting were to review the present status of ITER and to determine any required changes in the specifications for plasma measurements; to review the progress and develop plans for meeting the goals of the voluntary R and D tasks approved by the ITER Physics Committee within the Parties; to review and plan the work of the five specialists electronic working groups, and to hear reports of ITER relevant diagnostic developments in the Party Laboratories and assess their possible application to ITER

  13. Proceedings of twelfth ISMAS symposium cum workshop on mass spectrometry

    International Nuclear Information System (INIS)

    Alamelu, D.; Jaison, P.G.; Aggarwal, S.K.

    2007-03-01

    Mass Spectrometry is an important analytical tool and has encompassed almost all branches of science and technology including Agricultural, biology, Chemistry, Earth sciences, environment, Forensic Science, Medical Sciences, Hydrology, Nuclear Technology, Oceanography, Physics etc. Recent advancements in the instrumentation of Mass Spectrometry have further strengthened its role for various applications. It is indeed a matter of great pleasure to present this special Issue of ISMAS Bulletin which is brought out on the occasion of the 12th ISMAS Symposium cum Workshop on Mass spectrometry (12th ISMAS-WS 2007) being held at Cidade-de-Goa, Dona Paula, Goa from March 25 to 30, 2007 in association with National Institute of Oceanography, Goa. This Symposium cum Workshop is co-sponsored by Scientific Departments of Government of India. Papers relevant to INIS are indexed separately

  14. The Twelfth Indian Scientific Expedition to Antarctica: Events and achievements

    Digital Repository Service at National Institute of Oceanography (India)

    Dhargalkar, V.K.

    Chief Minister of Goa on 5 December 1992 at 1945 hours. Other dignitories present on the occasion were Shri Simon D'Souza, Dy. Speaker, Goa Assembly, Dr. P. Rama Rao, Secretary, Shri J.V.R. Prasad Rao, Jt Secretary, Department of Ocean Development, New...

  15. Meeting Report: The Twelfth International Mouse Genome Conference

    Energy Technology Data Exchange (ETDEWEB)

    Manolakou, Katerina; Cross, Sally H.; Simpson, Eleanor H.; Jackson, Ian J.

    1998-10-01

    The annual International Mouse Genome Conference (IMGC) is where, scientifically speaking, classical mouse genetics meets the relative newcomer of genomics. The 12th meeting took place last October in the delightful Bavarian village of Garmisch-Partenkirchen, and we were greeted by the sight on the mountains of the first snowfall of the season. However the discussions left little time for exploration. Minds of participants in Garmisch were focused by a recent document produced by the NIH and by discussions within other funding agencies worldwide. If implemented, the proposals will further enhance the status of the mouse as the principal model for study of the function of the human genome.

  16. The Perceptions of Twelfth-Grade Students on Financial Literacy

    Science.gov (United States)

    Harrelson, Joseph Christopher

    2010-01-01

    The problem of financial illiteracy at the high school level is becoming a growing pandemic in America. The current financial curriculum may not be preparing high school students against reported financial pitfalls. At the study site, high school students graduate without financial skills that may impact their future financial status. The purpose…

  17. On the conception of Homeric allegories in the twelfth century

    Directory of Open Access Journals (Sweden)

    Šijaković Jovana

    2016-01-01

    Full Text Available John Tzezes and St. Eustathius of Thessalonica, the two great Byzantine commentators of Homer and contemporaries, gave considerable attention to the tradition of allegorical interpretation of the Iliad and the Odyssey. The paper points to key differences in their understanding of the Homeric allegories. Although familiar with the same body of older interpretations, they tended to use it in a different way and show a rather personal view of the Poet and his work. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 177032: Tradicija, inovacija i identitet u vizantijskom svetu

  18. Proceedings of the twelfth target fabrication specialists' meeting

    International Nuclear Information System (INIS)

    1999-01-01

    Research in fabrication for inertial confinement fusion (ICF) comprises at least three broad categories: targets for high energy density physics on existing drivers, ignition capsule fabrication, and cryogenic fuel layer formation. The latter two are being pursued primarily for the National Ignition Facility (NIF). Scientists from over 14 laboratories, universities, and businesses contributed over 100 papers on all aspects of ICF target fabrication. The NIF is well along in construction and photos of poured concrete and exposed steel added to the technical excitement. It was clear from the meeting that there has been significant progress toward the fabrication of an ignition target for NIF and that new techniques are resulting in higher quality targets for high energy density research

  19. Review of the twelfth West Coast retrovirus meeting

    Directory of Open Access Journals (Sweden)

    Melar Marta

    2005-11-01

    Full Text Available Abstract Every year the Cancer Research Institute from University of California at Irvine organizes the West Coast Retrovirus Meeting where participants have a chance to discuss the latest progress in understanding the pathology of retroviruses. The 12th meeting was held at the Hyatt Regency Suites in Palm Springs, California from October 6th to October 9th 2005, with the major focus on human immunodeficiency virus (HIV pathogenesis. Philippe Gallay from The Scripps Research Institute and Thomas J. Hope from Northwestern University organized the meeting, which covered all the steps involved in the lifecycle of retroviruses with an emphasis on virus:host interactions. The trend in research appeared to be on the restriction of viral infection, both by the endogenous, cellular restriction factors, as well as by the potential antimicrobial compounds of known or unknown mechanisms. Additionally, new stories on the inevitable feedback from the host immune system were presented as well. HIV still represents a challenge that an army of motivated people has been working on for over 20 years. And yet, the field has not reached the plateau in knowledge nor enthusiasm, which was proven again in October 2005 in Palm Springs.

  20. Estimation of air quality by air pollution indices

    International Nuclear Information System (INIS)

    Liblik, Valdo; Kundel, Helmut

    1999-01-01

    A novel system for estimating the quality of atmospheric air in the over-ground air layer with the help of air pollution indices was developed. The method is based on a comparison of measured or calculated maximum short-term concentrations and average annual concentrations of pollutants with maximum permissible concentrations (with regard to human beings and vegetation). Special air quality estimation scales for residential areas and natural systems are presented. On the basis of the concentration of the substance under study zones of very high, high, rather high, moderate, low and very low air pollution were distinguished in the over-ground layer of the atmosphere. These are projected to land surface for landscape zonation. The application of the system of indices is demonstrated in the analysis of air quality for the towns of Kohtla-Jarve, Johvi and Kivioli (in 1997-1998). A comparative analysis of the air pollution zones distinguished on the basis of emissions and data from bio monitoring yielded satisfactory results. The system of air pollution indices developed enables to process the results of air monitoring in case of pollution fields of complicated composition so that the result for estimating the quality of ambient air in a residential area is easily understood by inhabitants and interpretable with the help of a special scale; analyse temporal changes in the quality of the air in towns, villages and other residential areas and use the results as basis for developing measures for reducing the pollution of ambient air; carry out zonation of large territories on the basis of air pollution levels (spatial air pollution zones are projected on the ground surface) and estimate air quality in places where air monitoring is lacking to forecast the possible effect of air pollution on natural systems (author)

  1. Indoor Air Pollution

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 1. Indoor Air Pollution - Danger at Home. N Pon Saravanan. General Article Volume 9 Issue 1 January 2004 pp 6-11. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/009/01/0006-0011. Keywords.

  2. Can you see Air?

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 6. Can you see Air? Andal Narayanan Joseph Samuel Supurna Sinha. Classroom Volume 12 Issue 6 June 2007 pp 71-75. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/012/06/0071-0075 ...

  3. Russia air management program

    Energy Technology Data Exchange (ETDEWEB)

    Pace, T.G. [U.S. Environmental Protection Agency, NC (United States); Markin, S. [Ministry of Environmental Protection and Natural Resources, Moscow (Sweden); Kosenkova, S.V. [Volgograd Environmental Services Administration, Volgograd (Russian Federation)

    1995-12-31

    The Russia Air Management Program is in the second year of a four-year cooperative program between the Russian Ministry of Environmental Protection and Natural Resources (MEPNR) and the U.S. Environmental Protection Agency (EPA) to improve national institutions, policies, and practices for air quality management in Russia. This program is part of the Environmental Policy and Technology project being conducted by the U.S. Agency for International Development. The Russia Air Management Program will pilot the application of potential air program improvements in the important industrial City of Volgograd which will enable the development, practical demonstration and evaluation of alternative approaches for improving AQM policies and practices in Russia. Volgograd has a progressive and environmentally enlightened local government, a diverse industrial base and a relatively healthy economy. It is located south of Moscow on the Volga River and was proposed by the Ministry of Environmental Protection and Natural Resources. It was selected after a site visit and a series of discussions with the Ministry, Volgograd officials, the World Bank and the EPA. Following the pilot, RAMP will work to facilitate implementation of selected parts of the pilot in other areas of Russia using training, technology transfer, and public awareness. (author)

  4. Ames Air Revitalization

    Science.gov (United States)

    Huang, Roger Z.

    2015-01-01

    This is an informal presentation presented to the University of Colorado, Boulder Bioastronautics group seminar. It highlights the key focal areas of the Air Revitalization Group research over the past year, including progress on the CO2 Removal and Compression System, testing of CDRA drying bed configurations, and adsorption research.

  5. Modeling indoor air pollution

    National Research Council Canada - National Science Library

    Pepper, D. W; Carrington, David B

    2009-01-01

    ... and ventilation from the more popular textbooks and monographs. We wish to especially acknowledge Dr. Xiuling Wang, who diligently converted many of our old FORTRAN codes into MATLAB files, and also developed the COMSOL example files. Also we thank Ms. Kathryn Nelson who developed the website for the book and indoor air quality computer codes. We are grateful to ...

  6. Outdoor air Pollution

    CSIR Research Space (South Africa)

    Forbes, PBC

    2016-07-01

    Full Text Available This chapter focuses on the air pollutants which are generally found in the troposphere and does not provide detail on specific areas where atmospheric pollutants and atmospheric chemistry may differ from that generally found, such as in the arctic...

  7. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    Howard, A.G.

    1981-01-01

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  8. Air Carrier Traffic Statistics.

    Science.gov (United States)

    2013-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  9. Air Carrier Traffic Statistics.

    Science.gov (United States)

    2012-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  10. Russia air management program

    International Nuclear Information System (INIS)

    Pace, T.G.; Markin, S.; Kosenkova, S.V.

    1995-01-01

    The Russia Air Management Program is in the second year of a four-year cooperative program between the Russian Ministry of Environmental Protection and Natural Resources (MEPNR) and the U.S. Environmental Protection Agency (EPA) to improve national institutions, policies, and practices for air quality management in Russia. This program is part of the Environmental Policy and Technology project being conducted by the U.S. Agency for International Development. The Russia Air Management Program will pilot the application of potential air program improvements in the important industrial City of Volgograd which will enable the development, practical demonstration and evaluation of alternative approaches for improving AQM policies and practices in Russia. Volgograd has a progressive and environmentally enlightened local government, a diverse industrial base and a relatively healthy economy. It is located south of Moscow on the Volga River and was proposed by the Ministry of Environmental Protection and Natural Resources. It was selected after a site visit and a series of discussions with the Ministry, Volgograd officials, the World Bank and the EPA. Following the pilot, RAMP will work to facilitate implementation of selected parts of the pilot in other areas of Russia using training, technology transfer, and public awareness. (author)

  11. Indoor Air Quality

    DEFF Research Database (Denmark)

    Selman, Ayser Dawod; Heiselberg, Per

    Overall purpose of the research is to provide an overview of the relevance and importance of various defined Indoor Air Quality (IAQ) parameters in a European perspective. Based on the report it should be possible to prioritize which countries to target for further activities as well as it should...

  12. Air quality conformity appendix.

    Science.gov (United States)

    2011-05-01

    Under the 1990 Clean Air Act Amendments (CAAA), because of the 8-hour ozone standard, Franklin, Delaware, Licking, Madison, Fairfield and Knox counties were designated as a basic nonattainment area for ozone in 2004. As a result of the PM 2.5 standar...

  13. Air Quality Monitoring Programme

    DEFF Research Database (Denmark)

    Kemp, K.; Palmgren, F.

    The Danish Air Quality Monitoring Programme (LMP IV) has been revised in accordance with the Framework Directive and the first three daughter directives of SO2, NOx/NO2, PM10, lead, benzene, CO and ozone. PM10 samplers are under installation and the installation will be completed during 2002...

  14. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  15. Fast Air Temperature Sensors

    DEFF Research Database (Denmark)

    Hendricks, Elbert

    1998-01-01

    The note documents briefly work done on a newly developed sensor for making fast temperature measurements on the air flow in the intake ports of an SI engine and in the EGR input line. The work reviewed has been carried out in close cooperation with Civ. Ing. Michael Føns, the author (IAU...

  16. Russia air management program

    Energy Technology Data Exchange (ETDEWEB)

    Pace, T G [U.S. Environmental Protection Agency, NC (United States); Markin, S [Ministry of Environmental Protection and Natural Resources, Moscow (Sweden); Kosenkova, S V [Volgograd Environmental Services Administration, Volgograd (Russian Federation)

    1996-12-31

    The Russia Air Management Program is in the second year of a four-year cooperative program between the Russian Ministry of Environmental Protection and Natural Resources (MEPNR) and the U.S. Environmental Protection Agency (EPA) to improve national institutions, policies, and practices for air quality management in Russia. This program is part of the Environmental Policy and Technology project being conducted by the U.S. Agency for International Development. The Russia Air Management Program will pilot the application of potential air program improvements in the important industrial City of Volgograd which will enable the development, practical demonstration and evaluation of alternative approaches for improving AQM policies and practices in Russia. Volgograd has a progressive and environmentally enlightened local government, a diverse industrial base and a relatively healthy economy. It is located south of Moscow on the Volga River and was proposed by the Ministry of Environmental Protection and Natural Resources. It was selected after a site visit and a series of discussions with the Ministry, Volgograd officials, the World Bank and the EPA. Following the pilot, RAMP will work to facilitate implementation of selected parts of the pilot in other areas of Russia using training, technology transfer, and public awareness. (author)

  17. Decentralization in Air Transportation

    NARCIS (Netherlands)

    Udluft, H.

    2017-01-01

    In this work,we demonstrate that decentralized control can result in stable, efficient, and robust operations in the Air Transportation System. We implement decentralized control for aircraft taxiing operations and use Agent-Based Modeling and Simulation to analyze the resulting system behavior

  18. Indoor air quality research

    International Nuclear Information System (INIS)

    1986-01-01

    The various types of pollutant found in indoor air are introduced and the effects on the health of the occupants of buildings summarized. The ''sick'' building syndrome is described in detail and the need for further investigation into its causes and remedies is stressed. 8 tabs

  19. AIR POLLUTION AND HUMMINGBIRDS

    Science.gov (United States)

    A multidisciplinary team of EPA-RTP ORD pulmonary toxicologists, engineers, ecologists, and statisticians have designed a study of how ground-level ozone and other air pollutants may influence feeding activity of the ruby-throated hummingbird (Archilochus colubris). Be...

  20. Air Pollution Surveillance Systems

    Science.gov (United States)

    Morgan, George B.; And Others

    1970-01-01

    Describes atmospheric data monitoring as part of total airpollution control effort. Summarizes types of gaseous, liquid and solid pollutants and their sources; contrast between urban and rural environmental air quality; instrumentation to identify pollutants; and anticipated new non-wet chemical physical and physiochemical techniques tor cetection…

  1. Learning AirWatch

    CERN Document Server

    Dunkerley, Mark

    2015-01-01

    If you are a technical professional who wants to dive deeper into the functionality offered by AirWatch or manage the solution, then this book will help you choose the best set of configuration, device management, and monitoring options that you can use to effectively manage your EMM implementation.

  2. Air quality indicators

    International Nuclear Information System (INIS)

    Clench-Aas, Jocelyn; Guerreiro, Cristina; Bartonova, Alena

    1999-06-01

    This report proposes and describes in detail several air quality indicators that may be used to describe population exposure. The suggested indicators account for temporal and spatial patterns of pollution and movements of individuals between different micro-environments. The Air Quality Indicator /AQI) should represent both the spatial and temporal aspects of pollution exposure that may have important effects on health. Two indicators are needed, the Population Air Quality Indicator and the Individual Air Quality Indicator. Mean concentrations, 98th percentile and maximum values are the traditional indicators for estimating exposure. the temporal variability of PM-10 and NO 2 , however, is here described by means of: 1) The rate of change of pollution as the difference between two consecutive hourly values and of 2) episodes, described in terms of number, duration and winter episode period, maximum concentration in the episode and integrated episode exposure (episode AOT50/100). The spatial variation of AQIs can be described in several ways, e.g.: 1) Concentrations in neighbouring grid squares can be compared as an indication of spatial variation and 2) point estimates can be compared to grid values for a description of variation within a grid. Both methods are presented here. A test of the representativity of static point estimates for pollution exposure is to compare them to an estimate of air pollution exposure accounting for movements between different locations, obtained using diaries. The ultimate aim of AQIs is to describe the population exposure to ambient pollution. This is done by estimating the number of people exposed using different characteristics of AQIs. The data used to describe these indicators originates from dispersion modelling of short-term air pollution concentrations in Oslo. Two series of data are used. One represents hour-for hour concentrations in the 1 km 2 grid system covering the city of Oslo, winter 1994/95, calculated by the grid

  3. Tonopah Test Range Air Monitoring. CY2014 Meteorological, Radiological, and Airborne Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Nikoloch, George [Desert Research Inst. (DRI), Las Vegas, NV (United States); Shadel, Craig [Desert Research Inst. (DRI), Las Vegas, NV (United States); Chapman, Jenny [Desert Research Inst. (DRI), Las Vegas, NV (United States); Mizell, Steve A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Las Vegas, NV (United States); Etyemezian, Vicken [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2015-10-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This test resulted in radionuclide-contaminated soils at Clean Slate I, II, and III. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III and at the TTR Range Operations Control center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soils beyond both the physical and administrative boundaries of the sites. Results for the calendar year (CY) 2014 monitoring are: (1) the gross alpha and gross beta values from the monitoring stations are approximately equivalent to the highest values observed during the CY2014 reporting at the surrounding Community Environmental Monitoring Program (CEMP) stations; (2) only naturally occurring radionuclides were identified in the gamma spectral analyses; (3) the ambient gamma radiation measurements indicate that the average annual gamma exposure is similar at all three monitoring stations and periodic intervals of increased gamma values appear to be associated with storm fronts passing through the area; and (4) the concentrations of both resuspended dust and saltated sand particles generally increase with increasing wind speed. Differences in the observed dust concentrations are likely the result of differences in the soil characteristics immediately adjacent to the monitoring stations. Neither the resuspended particulate radiological analyses nor the ambient gamma radiation measurements suggest wind transport of radionuclide-contaminated soils.

  4. Tonopah Test Range Air Monitoring: CY2013 Meteorological, Radiological, and Airborne Particulate Observations

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A [DRI; Nikolich, George [DRI; Shadel, Craig [DRI; McCurdy, Greg [DRI; Etyemezian, Vicken [DRI; Miller, Julianne J [DRI

    2014-10-01

    In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This test resulted in radionuclide-contaminated soils at Clean Slate I, II, and III. This report documents observations made during on-going monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to Clean Slate I and Clean Slate III and at the TTR Range Operations Control center. The primary objective of the monitoring effort is to determine if winds blowing across the Clean Slate sites are transporting particles of radionuclide-contaminated soils beyond both the physical and administrative boundaries of the sites. Results for the calendar year (CY) 2013 monitoring include: (1) the gross alpha and gross beta values from the monitoring stations are approximately equivalent to the highest values observed during the CY2012 reporting at the surrounding Community Environmental Monitoring Program (CEMP) stations (this was the latest documented data available at the time of this writing); (2) only naturally occurring radionuclides were identified in the gamma spectral analyses; (3) the ambient gamma radiation measurements indicate that the average annual gamma exposure is similar at all three monitoring stations and periodic intervals of increased gamma values appear to be associated with storm fronts passing through the area; and (4) the concentrations of both resuspended dust and saltated sand particles generally increase with increasing wind speed. However, differences in the observed dust concentrations are likely due to differences in the soil characteristics immediately adjacent to the monitoring stations. Neither the resuspended particulate radiological analyses nor the ambient gamma radiation measurements suggest wind transport of radionuclide-contaminated soils.

  5. Air Power's First Among Equals: Why Air Superiority Still Matters

    National Research Council Canada - National Science Library

    Slawson, Andrew T

    2008-01-01

    .... History is replete with examples of successful or failed air superiority campaigns. This paper details air superiority's role in both the Battle of Britain, and the 1967 Six Day War's Operation MOKED...

  6. Nitrogen fluorescence in air for observing extensive air showers

    CERN Document Server

    Keilhauer, B; Fraga, M; Matthews, J; Sakaki, N; Tameda, Y; Tsunesada, Y; Ulrich, A

    2012-01-01

    Extensive air showers initiate the fluorescence emissions from nitrogen molecules in air. The UV-light is emitted isotropically and can be used for observing the longitudinal development of extensive air showers in the atmosphere over tenth of kilometers. This measurement technique is well-established since it is exploited for many decades by several cosmic ray experiments. However, a fundamental aspect of the air shower analyses is the description of the fluorescence emission in dependence on varying atmospheric conditions. Different fluorescence yields affect directly the energy scaling of air shower reconstruction. In order to explore the various details of the nitrogen fluorescence emission in air, a few experimental groups have been performing dedicated measurements over the last decade. Most of the measurements are now finished. These experimental groups have been discussing their techniques and results in a series of \\emph{Air Fluorescence Workshops} commenced in 2002. At the 8$^{\\rm{th}}$ Air Fluoresc...

  7. Air sampling in the workplace

    International Nuclear Information System (INIS)

    Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R.; Wiblin, C.M.; McGuire, S.A.

    1993-09-01

    This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC's Regulatory Guide 8.25, Revision 1, ''Air sampling in the Workplace.'' That guide addresses air sampling to meet the requirements in NRC's regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed

  8. EN EL AIRE / In the air

    Directory of Open Access Journals (Sweden)

    Andrés López Fernández

    2011-11-01

    Full Text Available RESUMEN En el aire es un viaje a la primera mitad del siglo XX que nos tratará de acercar la frescura y oportunidad de las calles corredor y los jardines en la ciudad vertical. Se inicia en 1909 en Nueva York, con la publicación por la revista Life de La Torre del Globo, se acerca al Inmueble-Villas y al Plan Obus para Argel de Le Corbusier, y finaliza en 1952 con el proyecto para el conjunto residencial de Golden Lane en Londres de A. y P. Smithson. Fragmentos para la ciudad vertical que se construía sobre papel, tras el espejo, paralela en el tiempo, pero muy distinta a la ciudad real, con el objetivo entre otros de integrar arquitectura y naturaleza. Esas propuestas siguen teniendo hoy un gran valor, en un panorama en que el espacio público ligado a la vivienda colectiva, prácticamente ha desaparecido, y el esfuerzo que se demanda al arquitecto se centra, en tejer a modo de encaje de bolillos, una fachada que envuelva un programa de vivienda, funcional y espacialmente obsoleto. SUMMARY In the air, is a journey to the first half of the twentieth century that will try to bring us to the freshness and opportunity of the corridor streets and gardens in the vertical city. It begins in 1909 in New York, with the publication in Life magazine of the Globe Tower, it approaches the Immeubles-Villas and Plan Obus for Algiers by Le Corbusier, and ends in 1952 with the project for the Golden Lane Estate residential complex in London, by A. and P. Smithson. Fragments for the vertical city that was constructed on paper, behind the mirror, parallel in time, but was very different from the real city, with the aim, inter alia, of integrating architecture and nature. These proposals continue to have great value today, in a scenario where the public space linked to the collective home has virtually disappeared, and the effort that is demanded of the architect focuses on weaving a facade like bobbin lace around a functionally and spatially obsolete housing

  9. A Breath of Fresh Air: Addressing Indoor Air Quality

    Science.gov (United States)

    Palliser, Janna

    2011-01-01

    Indoor air pollution refers to "chemical, biological, and physical contamination of indoor air," which may result in adverse health effects (OECD 2003). The causes, sources, and types of indoor air pollutants will be addressed in this article, as well as health effects and how to reduce exposure. Learning more about potential pollutants in home…

  10. Air-cooled, hydrogen-air fuel cell

    Science.gov (United States)

    Shelekhin, Alexander B. (Inventor); Bushnell, Calvin L. (Inventor); Pien, Michael S. (Inventor)

    1999-01-01

    An air-cooled, hydrogen-air solid polymer electrolyte (SPE) fuel cell with a membrane electrode assembly operatively associated with a fluid flow plate having at least one plate cooling channel extending through the plate and at least one air distribution hole extending from a surface of the cathode flow field into the plate cooling channel.

  11. Air pollution control in India

    International Nuclear Information System (INIS)

    Jain, S.K.

    1995-01-01

    Prior to rapid spurt in industrialization in India, people were used to inhale pure air containing about 78% nitrogen, 21% oxygen and some carbon dioxide. But afterwards this composition of pure air was disturbed as a result of increased economic activities. Air, now a days also contains sulphur dioxide, carbon monoxide, nitrogen oxides etc., etc. which are extremely harmful for human health. Virulence of air pollution was realised in late eighties after Bhopal Gas Tragedy (BGT) and an effective air quality management started taking shape in India afterwards. The basic components of air quality management are legislation and regulations, emission inventory, air quality standards and monitoring, air dispersion models and installation of pollution control equipment which are being discussed in this paper. (author). 15 refs., 5 tabs

  12. Air Markets Program Data (AMPD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Markets Program Data tool allows users to search EPA data to answer scientific, general, policy, and regulatory questions about industry emissions. Air...

  13. Air Compliance Complaint Database (ACCD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — THIS DATA ASSET NO LONGER ACTIVE: This is metadata documentation for the Region 7 Air Compliance Complaint Database (ACCD) which logs all air pollution complaints...

  14. Air Emissions Factors and Quantification

    Science.gov (United States)

    Emissions factors are used in developing air emissions inventories for air quality management decisions and in developing emissions control strategies. This area provides technical information on and support for the use of emissions factors.

  15. Iron-Air Rechargeable Battery

    Science.gov (United States)

    Narayan, Sri R. (Inventor); Prakash, G.K. Surya (Inventor); Kindler, Andrew (Inventor)

    2014-01-01

    Embodiments include an iron-air rechargeable battery having a composite electrode including an iron electrode and a hydrogen electrode integrated therewith. An air electrode is spaced from the iron electrode and an electrolyte is provided in contact with the air electrode and the iron electrodes. Various additives and catalysts are disclosed with respect to the iron electrode, air electrode, and electrolyte for increasing battery efficiency and cycle life.

  16. Human preference for air movement

    DEFF Research Database (Denmark)

    Toftum, Jørn; Melikov, Arsen Krikor; Tynel, A.

    2002-01-01

    Human preference for air movement was studied at slightly cool, neutral, and slightly warm overall thermal sensations and at temperatures ranging from 18 deg.C to 28 deg.C. Air movement preference depended on both thermal sensation and temperature, but large inter-individual differences existed...... between subjects. Preference for less air movement was linearly correlated with draught discomfort, but the percentage of subjects who felt draught was lower than the percentage who preferred less air movement....

  17. Air Pollution in Europe

    International Nuclear Information System (INIS)

    1997-09-01

    In spite of improvements relative to air pollution, there is still much to do. more than thirty millions of European people are exposed to sulfur dioxide concentrations superior to guide values for health fixed by European Union, 20% of ecosystems in Europe are above the critical charges in the area of acidification and 33% concern eutrophication. Relative to the carbon dioxide, it is not sure that European Union realize the objective to stabilize the emissions for the year 2000 at the level of the year 1990, because of the increasing of automobile traffic and the energy consumption. Four subjects are presented: the climatic change, acidification and eutrophication, tropospheric ozone and air quality. (N.C.)

  18. Air pollution and lichens

    Energy Technology Data Exchange (ETDEWEB)

    Ferry, B W; Baddeley, M S; Hawksworth, D L [eds.

    1973-01-01

    This volume reflects the particular concern of many biologists for the effects of air pollution and illustrates the special values of lichens as plants suitable for such studies. It brings together contributions from many experts in this field and includes much previously unpublished data, as well as up-to-date review chapters. Emphasis is placed on the logical progression from field observational studies to critical laboratory investigations aimed at elucidating the modes of action of various air pollutants on the living tissues of lichens. The action of such pollutants on vascular plants is also discussed. It is the editors' intention that the book be both a reference volume and an encouragement for further wor

  19. Lidar: air pollution applications

    International Nuclear Information System (INIS)

    Collis, R.T.H.

    1977-01-01

    This introduction to the use of lidar in air pollution applications is mainly concerned with its capability to detect and monitor atmospheric particulates by elastic backscattering. Even when quite imperceptible to the eye, such particulates may be detected at ranges of several kilometers even by lidars of modest performance. This capability is valuable in connection with air pollution in the following ways: by mapping and tracking inhomogeneities in particulate concentration, atmospheric structure and motion may be monitored; measurements of the optical properties of the atmosphere provide an indication of turbidity or of particulate number or mass concentrations; and the capability of obtaining at a single point return signals from remote atmospheric volumes makes it possible to make range-resolved measurements of gaseous concentration along the path by using the resonant absorption of energy of appropriate wavelengths

  20. Air transport system

    CERN Document Server

    Schmitt, Dieter

    2016-01-01

    The book addresses all major aspects to be considered for the design and operation of aircrafts within the entire transportation chain. It provides the basic information about the legal environment, which defines the basic requirements for aircraft design and aircraft operation. The interactions between  airport, air traffic management and the airlines are described. The market forecast methods and the aircraft development process are explained to understand the very complex and risky business of an aircraft manufacturer. The principles of flight physics as basis for aircraft design are presented and linked to the operational and legal aspects of air transport including all environmental impacts. The book is written for graduate students as well as for engineers and experts, who are working in aerospace industry, at airports or in the domain of transport and logistics.

  1. Hot air balloon engine

    Energy Technology Data Exchange (ETDEWEB)

    Edmonds, Ian [Solartran Pty Ltd, 12 Lentara Street, Kenmore, Brisbane 4069 (Australia)

    2009-04-15

    This paper describes a solar powered reciprocating engine based on the use of a tethered hot air balloon fuelled by hot air from a glazed collector. The basic theory of the balloon engine is derived and used to predict the performance of engines in the 10 kW to 1 MW range. The engine can operate over several thousand metres altitude with thermal efficiencies higher than 5%. The engine thermal efficiency compares favorably with the efficiency of other engines, such as solar updraft towers, that also utilize the atmospheric temperature gradient but are limited by technical constraints to operate over a much lower altitude range. The increased efficiency allows the use of smaller area glazed collectors. Preliminary cost estimates suggest a lower $/W installation cost than equivalent power output tower engines. (author)

  2. Air cathode structure manufacture

    Science.gov (United States)

    Momyer, William R.; Littauer, Ernest L.

    1985-01-01

    An improved air cathode structure for use in primary batteries and the like. The cathode structure includes a matrix active layer, a current collector grid on one face of the matrix active layer, and a porous, nonelectrically conductive separator on the opposite face of the matrix active layer, the collector grid and separator being permanently bonded to the matrix active layer. The separator has a preselected porosity providing low IR losses and high resistance to air flow through the matrix active layer to maintain high bubble pressure during operation of the battery. In the illustrated embodiment, the separator was formed of porous polypropylene. A thin hydrophobic film is provided, in the preferred embodiment, on the current collecting metal grid.

  3. Aeromicrobiology/air quality

    Science.gov (United States)

    Andersen, Gary L.; Frisch, A.S.; Kellogg, Christina A.; Levetin, E.; Lighthart, Bruce; Paterno, D.

    2009-01-01

    The most prevalent microorganisms, viruses, bacteria, and fungi, are introduced into the atmosphere from many anthropogenic sources such as agricultural, industrial and urban activities, termed microbial air pollution (MAP), and natural sources. These include soil, vegetation, and ocean surfaces that have been disturbed by atmospheric turbulence. The airborne concentrations range from nil to great numbers and change as functions of time of day, season, location, and upwind sources. While airborne, they may settle out immediately or be transported great distances. Further, most viable airborne cells can be rendered nonviable due to temperature effects, dehydration or rehydration, UV radiation, and/or air pollution effects. Mathematical microbial survival models that simulate these effects have been developed.

  4. Aqueous lithium air batteries

    Science.gov (United States)

    Visco, Steven J.; Nimon, Yevgeniy S.; De Jonghe, Lutgard C.; Petrov, Alexei; Goncharenko, Nikolay

    2017-05-23

    Aqueous Li/Air secondary battery cells are configurable to achieve high energy density and prolonged cycle life. The cells include a protected a lithium metal or alloy anode and an aqueous catholyte in a cathode compartment. The aqueous catholyte comprises an evaporative-loss resistant and/or polyprotic active compound or active agent that partakes in the discharge reaction and effectuates cathode capacity for discharge in the acidic region. This leads to improved performance including one or more of increased specific energy, improved stability on open circuit, and prolonged cycle life, as well as various methods, including a method of operating an aqueous Li/Air cell to simultaneously achieve improved energy density and prolonged cycle life.

  5. Air Pollution, Causes and Cures.

    Science.gov (United States)

    Manufacturing Chemists Association, Washington, DC.

    This commentary on sources of air pollution and air purification treatments is accompanied by graphic illustrations. Sources of carbon monoxide, sulfur oxides, nitrogen oxides, and hydrocarbons found in the air are discussed. Methods of removing these pollutants at their source are presented with cut-away diagrams of the facilities and technical…

  6. Air Pollution in Museum Buildings

    DEFF Research Database (Denmark)

    Ryhl-Svendsen, Morten

    2017-01-01

    This paper reviews the main air pollutants relevant for preservation of cultural heritage objects. Air pollutants may originate from outdoor or indoor sources. Indoor sources include the emission of corrosive vapors from construction materials used for museum display settings. Air pollution may...

  7. Indoor Air Quality in Schools.

    Science.gov (United States)

    Torres, Vincent M.

    Asserting that the air quality inside schools is often worse than outdoor pollution, leading to various health complaints and loss of productivity, this paper details factors contributing to schools' indoor air quality. These include the design, operation, and maintenance of heating, ventilating, and air conditioning (HVAC) systems; building…

  8. Hydrocarbons and air pollution

    International Nuclear Information System (INIS)

    Herz, O.

    1992-01-01

    This paper shows the influence of hydrocarbons vapors, emitted by transports or by volatile solvents using, on air pollution. Hydrocarbons are the principal precursors of photochemical pollution. After a brief introduction on atmospheric chemistry and photochemical reactions, the author describes the french prevention program against hydrocarbons emissions. In the last chapter, informations on international or european community programs for photochemical pollution study are given. 5 figs., 10 tabs

  9. Air pollution and lichens

    Energy Technology Data Exchange (ETDEWEB)

    Ferry, B W; Baddeley, M S; Hawksworth, D L [eds.

    1973-01-01

    This volume reflects the concern of biologists for the effects of air pollution and illustrates the special values of lichens as plants suitable for such studies. Emphasis is placed on the logical progression from field observational studies to laboratory investigations aimed at elucidating the modes of action of various pollutants. The actions of pollutants on vascular plants is also discussed. Separate analytics are included for 17 chapters.

  10. Air pollution and bronchitis

    Energy Technology Data Exchange (ETDEWEB)

    Pemberton, J; Goldberg, C

    1954-01-01

    Bronchitis mortality in males and females 45 to 65 or over 65 years of age was compared with air pollution in the county boroughs of England and Wales in 1950 to 1952. There was significant association between SO/sub 2/ and bronchitis mortality for men but only occasionally significant for women. Association between particulate matter and bronchitis was less consistent. Socio-economic class had no association with pollutant levels suggesting this factor does not affect bronchitis mortality significantly.

  11. Olfactometric pollution of air

    OpenAIRE

    Lucia Haraslínová

    2009-01-01

    This paper describes the olfactometric assessment of volatile organic compounds emitted by coating films.It describes the measurements of concentration, intensity, hedonic tone and character of odor caused by emissions of volatile organic compounds. VOCs’ emitted in to the small-space chamber with capacity of 1 m3 were tested by dynamic olfactometric method. Paper also contains a comparison of olfactometric air pollution of two different types of coating films. The work is aimed to determine ...

  12. Deployable Engine Air Brake

    Science.gov (United States)

    2014-01-01

    On approach, next-generation aircraft are likely to have airframe noise levels that are comparable to or in excess of engine noise. ATA Engineering, Inc. (ATA) is developing a novel quiet engine air brake (EAB), a device that generates "equivalent drag" within the engine through stream thrust reduction by creating a swirling outflow in the turbofan exhaust nozzle. Two Phase II projects were conducted to mature this technology: (1) a concept development program (CDP) and (2) a system development program (SDP).

  13. Air corrosion in storing

    International Nuclear Information System (INIS)

    Mazaudier, F.; Feron, D.; Baklouti, M.; Midoux, N.

    2001-01-01

    The air corrosiveness of a radioactive waste package has been estimated in a store inside which the environmental conditions are supposed to be rather close to the outside ones. It is expressed according to the ISO 9223 standard, from the humidification value and the amounts of sulfur dioxide and chlorine ions. A computer code has been perfected too; the thermal behaviour of the package can then been determined. (O.M.)

  14. Urban air quality

    International Nuclear Information System (INIS)

    Fenger, J.

    1999-01-01

    Since 1950 the world population has more than doubled, and the global number of cars has increased by a factor of 10. In the same period the fraction of people living in urban areas has increased by a factor of 4. In year 2000 this will amount to nearly half of the world population. About 20 urban regions will each have populations above 10 million people. Seen over longer periods, pollution in major cities tends to increase during the built up phase, they pass through a maximum and are then again reduced, as abatement strategies are developed. In the industrialised western world urban air pollution is in some respects in the last stage with effectively reduced levels of sulphur dioxide and soot. In recent decades however, the increasing traffic has switched the attention to nitrogen oxides, organic compounds and small particles. In some cities photochemical air pollution is an important urban problem, but in the northern part of Europe it is a large-scale phenomenon, with ozone levels in urban streets being normally lower than in rural areas. Cities in Eastern Europe have been (and in many cases still are) heavily polluted. After the recent political upheaval, followed by a temporary recession and a subsequent introduction of new technologies, the situation appears to improve. However, the rising number of private cars is an emerging problem. In most developing countries the rapid urbanisation has so far resulted in uncontrolled growth and deteriorating environment. Air pollution levels are here still rising on many fronts. Apart from being sources of local air pollution, urban activities are significant contributors to transboundary pollution and to the rising global concentrations of greenhouse gasses. Attempts to solve urban problems by introducing cleaner, more energy-efficient technologies will generally have a beneficial impact on these large-scale problems. Attempts based on city planning with a spreading of the activities, on the other hand, may generate

  15. Controlled air pyrolysis incinerator

    International Nuclear Information System (INIS)

    Dufrane, K.H.; Wilke, M.

    1982-01-01

    An advanced controlled air pyrolysis incinerator has been researched, developed and placed into commercial operation for both radioactive and other combustible wastes. Engineering efforts cocentrated on providing an incinerator which emitted a clean, easily treatable off-gas and which produced a minimum amount of secondary waste. Feed material is continuously fed by gravity into the system's pyrolysis chamber without sorting, shredding, or other such pretreatment. Metal objects, liquids such as oil and gasoline, or solid products such as resins, blocks of plastic, tire, animal carcasses, or compacted trash may be included along with normal processed waste. The temperature of the waste is very gradually increased in a reduced oxygen atmosphere. Volatile pyrolysis gases are produced, tar-like substances are cracked and the resulting product, a relatively uniform, easily burnable material, is introduced into the combustion chamber. Steady burning is thus accomplished under easily controlled excess air conditions with the off-gasthen passing through a simple dry clean-up system. Gas temperatures are then reduced by air dilution before passing through final HEPA filters. Both commercial and nuclear installations have been operated with the most recent application being the central incinerator to service West Germany's nuclear reactors

  16. DISKURSUS BAHAN BAKAR AIR

    Directory of Open Access Journals (Sweden)

    Poempida Hidayatulloh

    2015-06-01

    Full Text Available Kebutuhan akan energi bagi manusia adalah suatu keniscayaan. Oleh karena itu pencarian manusia dalam menemukan suatu energi yang berkelanjutan (sustainable adalah suatu proses alamiah yang terjadi secara terus-menerus. Keterbatasan manusia dalam mendapatkan energi selalu berkutat pada paradigma keberadaan hukum kekekalan energi yang menjadi basis pemikiran fisika klasik. Air adalah suatu senyawa yang senantiasa ada di sekitar kita dan tersedia dalam berbagai wujud. Senyawa Air (H2O terdiri dari atom hidrogen (H2 dan oksigen (O2 yang keduanya dapat dibakar dan membantu proses pembakaran. Di mana dalam pembakaran akan tercipta energi yang dapat dimanfaatkan untuk menjadi energi gerak seperti dalam mesin bakar (combustion engine. Proses penguraian senyawa air menjadi hidrogen dan Oksigen dapat dilakukan melalui proses elektrolisa. Proses elektrolisa secara langsung akan membutuhkan energi listrik dalam jumlah yang tidak sedikit. Namun proses elektrolisa yang tepat dapat menghasilkan Brown Gas (HHO yang mempunyai daya bakar yang cukup besar. Tulisan ini membahas dilema pemakaian Brown Gas dalam konteks energi yang dihasilkan dengan perbandingan energi yang diperlukan untuk menghasilkannya. Komparasi energi ini ditujukan untuk menunjukkan apakah kemudian Brown Gas dapat lebih lanjut digunakan untuk menjadi energi penggerak mesin yang ekonomis. Pembahasan tentang terjadinya pelanggaran terhadap hukum kekekalan energi berbasis fisika klasik secara filosofis pun termaktub.

  17. Air System Information Management

    Science.gov (United States)

    Filman, Robert E.

    2004-01-01

    I flew to Washington last week, a trip rich in distributed information management. Buying tickets, at the gate, in flight, landing and at the baggage claim, myriad messages about my reservation, the weather, our flight plans, gates, bags and so forth flew among a variety of travel agency, airline and Federal Aviation Administration (FAA) computers and personnel. By and large, each kind of information ran on a particular application, often specialized to own data formats and communications network. I went to Washington to attend an FAA meeting on System-Wide Information Management (SWIM) for the National Airspace System (NAS) (http://www.nasarchitecture.faa.gov/Tutorials/NAS101.cfm). NAS (and its information infrastructure, SWIM) is an attempt to bring greater regularity, efficiency and uniformity to the collection of stovepipe applications now used to manage air traffic. Current systems hold information about flight plans, flight trajectories, weather, air turbulence, current and forecast weather, radar summaries, hazardous condition warnings, airport and airspace capacity constraints, temporary flight restrictions, and so forth. Information moving among these stovepipe systems is usually mediated by people (for example, air traffic controllers) or single-purpose applications. People, whose intelligence is critical for difficult tasks and unusual circumstances, are not as efficient as computers for tasks that can be automated. Better information sharing can lead to higher system capacity, more efficient utilization and safer operations. Better information sharing through greater automation is possible though not necessarily easy.

  18. Air Consumption Analysis of Air-Jet Weaving

    Directory of Open Access Journals (Sweden)

    RAJ KUMAR KHIANI

    2016-07-01

    Full Text Available In Textile industry, production is mostly key concern for Industry owner. This always has attracted researchers and machines manufacturers to make new developments in process and machines. Air-jet is one of the leading and successful highest productive weaving machines. However, it is now well established that due to add of charges of compressed air, manufacturing cost of air-jet weaving machine is higher as compared with rapier and projectile weaving machines. This is why countries having energy issues do not prefer air-jet weaving machines comparing projectile weaving machines. In this regard, several researchers and machine manufacturers have continuously been working to improve the efficiency of air-jet weft insertion. However, industry practice is as important as design made by researchers. The aim of this research is to investigate the air consumption of air-jet weaving on industrial scale practice. In this study, five weaving machine of same manufacturer and model were selected. It was observed that despite of manufacturing same quality of fabric, air consumption was varying almost in all weaving machines. Conventionally, mill workers adopt hit and trial practice in weaving industry including airpressure setting which leads to variation of nozzle pressure. Main reason of disparity of air consumption in air-jet weaving machines may be variation of distance from compressor to weaving machines, number of joints, un-necessary valve opening and pipes leakages cause an increase of compressed air consumption.

  19. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  20. An experimental evaluation on air purification performance of Clean-Air Heat Pump (CAHP) air cleaner

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Sun, Yuexia

    2018-01-01

    was 96.8%, which indicated that the most of gaseous pollutants were not accumulated in the CAHP. The regeneration temperature for the wheel could affect the air purification performance of CAHP. At 70 °C of regeneration temperature, the air-cleaning efficiency reached 96.7%. Up to 70% of the outdoor air......The escalation of energy consumption in buildings and heightened concerns about acceptable indoor air quality stimulate interest in the usage of air cleaner as an adjunct for indoor environmental conditioning. A regenerative desiccant wheel integrated into a ventilation system termed Clean-Air Heat...... Pump (CAHP) can improve the air quality during the process of dehumidification without using additional energy. An experimental study in a field lab was performed to investigate the air cleaning performance of CAHP. Photoacoustic gas analyzer-INNOVA was used to characterize chemical removal of indoor...

  1. Air Risk Information Support Center

    Energy Technology Data Exchange (ETDEWEB)

    Shoaf, C.R.; Guth, D.J. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31

    The Air Risk Information Support Center (Air RISC) was initiated in early 1988 by the US Environmental Protection Agency`s (EPA) Office of Health and Environmental Assessment (OHEA) and the Office of Air Quality Planning and Standards (OAQPS) as a technology transfer effort that would focus on providing information to state and local environmental agencies and to EPA Regional Offices in the areas of health, risk, and exposure assessment for toxic air pollutants. Technical information is fostered and disseminated by Air RISCs three primary activities: (1) a {open_quotes}hotline{close_quotes}, (2) quick turn-around technical assistance projects, and (3) general technical guidance projects. 1 ref., 2 figs.

  2. Clean air in the Anthropocene.

    Science.gov (United States)

    Lelieveld, Jos

    2017-08-24

    In atmospheric chemistry, interactions between air pollution, the biosphere and human health, often through reaction mixtures from both natural and anthropogenic sources, are of growing interest. Massive pollution emissions in the Anthropocene have transformed atmospheric composition to the extent that biogeochemical cycles, air quality and climate have changed globally and partly profoundly. It is estimated that mortality attributable to outdoor air pollution amounts to 4.33 million individuals per year, associated with 123 million years of life lost. Worldwide, air pollution is the major environmental risk factor to human health, and strict air quality standards have the potential to strongly reduce morbidity and mortality. Preserving clean air should be considered a human right, and is fundamental to many sustainable development goals of the United Nations, such as good health, climate action, sustainable cities, clean energy, and protecting life on land and in the water. It would be appropriate to adopt "clean air" as a sustainable development goal.

  3. Air Traffic Control Tools Assessment

    Directory of Open Access Journals (Sweden)

    Tomáš Noskievič

    2017-04-01

    Full Text Available Undoubtedly air transport in today’s world wouldn’t be able to exist without any air traffic control service. As the air transport has been coming through major changes and it has been expanding, it is assumed that its volume will be doubled in the next 15 years. Air traffic control uses strictly organised procedures to ensure safe course of air operations. With the skies covered with more airplanes every year, new tools must be introduced to allow the controllers to manage this rising amount of flying aircraft and to keep the air transport safe. This paper provides a comprehensive and organized material, which describes the newest tools and systems used by air traffic control officers. It proposes improvements for further research and development of ATC tools.

  4. 33 CFR 334.1280 - Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force. 334.1280 Section 334.1280 Navigation and Navigable... REGULATIONS § 334.1280 Bristol Bay, Alaska; air-to-air weapon range, Alaskan Air Command, U.S. Air Force. (a...

  5. Project 57 Air Monitoring Report: October 1, 2013, through December 31, 2014

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Nikolich, George [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Reno, NV (United States); Shadel, Craig [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2016-02-01

    On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley north east of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DoD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a nonnuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DoD. Various radiological surveys have been performed in the area and in 2007, the DOE expanded the demarked contamination area by posting signs 200 to 400 feet (60 to 120 meters) outside of the original fence. Plutonium in soil is thought to attach preferentially to smaller particles. Therefore, redistribution of soil particulates by wind (dust) is the mechanism most likely to transport plutonium beyond the boundary of the Project 57 contamination area. In 2011, DRI installed two instrumentation towers to measure radiological, meteorological, and dust conditions. The monitoring activity was implemented to determine if radionuclide contamination was detectable in samples of airborne dust and characterize meteorological and environmental parameters that influence dust transport. Collected data also permits comparison of radiological conditions at the Project 57 monitoring stations to conditions observed at Community Environmental Monitoring Program (CEMP) stations around the NTTR. Biweekly samples of airborne particulates are submitted for laboratory

  6. Teatro al aire libre

    Directory of Open Access Journals (Sweden)

    Philippe Canac

    2016-11-01

    Full Text Available Siendo cada vez más frecuentes y numerosas las peregrinaciones a la basílica de Notre Dame, de Laus (Altos Alpes, su capacidad resultaba hace tiempo insuficiente para acoger a sus peregrinos. Este fue el motivo de crear, en un terreno situado ante el atrio de la basílica, un conjunto, que permitiese celebrar misas al aire libre, ceremonias litúrgicas o representaciones de teatro religioso y que dispusiese de todas las posibilidades para conseguir la libertad del juego escénico.

  7. Extensive air showers

    CERN Document Server

    Rao, M V S

    1997-01-01

    Ultrahigh energy cosmic rays carry information about their sources and the intervening medium apart from providing a beam of particles for studying certain features of high energy interactions currently inaccessible at man-made accelerators. They can at present be studied only via the extensive air showers (EAS's) they generate while passing through the Earth's atmosphere, since their fluxes are too low for the experiments of limited capability flown in balloons and satellites. The EAS is generated by a series of interactions of the primary cosmic ray and its progeny with the atmospheric nucle

  8. Control of air toxics

    International Nuclear Information System (INIS)

    Livengood, C.D.

    1995-01-01

    For more than 10 years, Argonne National Laboratory has supported the US DOE's Flue Gas Cleanup Program objective by developing new or improved environmental controls for industries that use fossil fuels. Argonne's pollutant emissions research has ranged from experiments in the basic chemistry of pollution-control systems, through laboratory-scale process development and testing, to pilot-scale field tests of several technologies. The work on air toxics is currently divided into two components: Investigating measures to improve the removal of mercury in existing pollution-control systems applied to coal combustion; and, Developing sensors and control techniques for emissions found in the textile industry

  9. Island in the Air

    DEFF Research Database (Denmark)

    Simonsen, Dorthe Gert

    2017-01-01

    In this article, I explore the formation of airspace in Britain from 1910 to 1913. The technology of flight challenged the “flat discourse” of nationalized geography, drawing up instead a volumetric space in the sky as airplanes flew from the Continent to England. The drive to control aerial...... extension of the Island Kingdom, extrapolating its coastal borders into the sky. However, even as Parliament passed the Aerial Navigation Act in 1913, this legal construction of an island in the air could not endure the agency of airplanes. The formation of airspace, I argue, is a history particularly well...

  10. Baltimore Air Toxics Study (BATS)

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, D.A. [Sullivan Environmental Consulting, Inc., Alexandria, VA (United States)

    1996-12-31

    The Baltimore Air Toxics Study is one of the three urban air toxics initiatives funded by EPA to support the development of the national air toxics strategy. As part of this project, the Air Quality Integrated Management System (AIMS) is under development. AIMS is designed to bring together the key components of urban air quality management into an integrated system, including emissions assessment, air quality modeling, and air quality monitoring. Urban area source emissions are computed for a wide range of pollutants and source categories, and are joined with existing point source emissions data. Measured air quality data are used to evaluate the adequacy of the emissions data and model treatments as a function of season, meteorological parameters, and daytime/nighttime conditions. Based on tested model performance, AIMS provides the potential to improve the ability to predict air quality benefits of alternative control options for criteria and toxic air pollutants. This paper describes the methods used to develop AIMS, and provides examples from its application in the Baltimore metropolitan area. The use of AIMS in the future to enhance environmental management of major industrial facilities also will be addressed in the paper.

  11. Air quality model guideline

    International Nuclear Information System (INIS)

    Idriss, A.; Spurrell, F.

    2009-06-01

    Alberta Environment has developed a guidelines for operations and proposed operations that require approvals under the province's Environmental Protection and Enhancement Act or that operate under a code of practice for emissions to the atmosphere. In an effort to ensure consistency in the use of dispersion models for regulatory applications in Alberta, this document provided detailed guidance on suitable methods and approaches that should be employed to assess air quality from emission sources, specifically, information required to demonstrate that a source meets the Alberta ambient air quality objectives. The document outlined the statutory authority and provided an overview of the approach. It provided detailed advice on the types and uses of dispersion models with particular reference to the modelling protocol, input data, and output interpretation. Guidance on the application of regulatory models were also presented. Various models were described and their intended uses were explained. Internet addresses for different modelling resources were also offered. Last, some information about regional modelling in the province of Alberta was discussed. 40 refs., 4 tabs., 7 figs., 3 appendices.

  12. Building air exhaustion device

    International Nuclear Information System (INIS)

    Suzuki, Seijiro.

    1995-01-01

    An opening is formed on the side wall of a building such as of a nuclear power plant, and a blow out panel is held (supported) by a clip for closing the opening. A large-diameter pipeline is connected at one end to the opening so as to cover the blow out panel, and immersed at the other end in a pool water. When a pipeline such as of main steam pipelines is ruptured in the building, high temperature and high pressure coolants are flown out from the ruptured port, and the pressure in the building is elevated. The blow out panel falls off from the side of the building by the elevation of the pressure in the building. Steams or compressed air discharged from the opening is introduced to the pool through the large diameter pipeline, then the steams are condensed by the pool water and radioactive materials contained in the condensed steams are kept in the pool water. Radioactive materials contained in the released compression air are also removed into the pool water. (I.N.)

  13. Air pollution - health and management

    Energy Technology Data Exchange (ETDEWEB)

    Klug, W; Runca, E; Suess, M J [eds.

    1984-01-01

    The proceedings of a joint workshop of the World Health Organization and the International Institute for Applied Systems Analysis are presented. The workshop was to review the interaction between man's industrial and urban activities and the environment, and the relationship between ambient air quality and human health, and to examine the effectiveness of proper management on the control and abatement of air pollution. The discussion topics included atmospheric processes and respective modelling, air pollution impact on human health, effects of air pollutants on aquatic and terrestrial ecosystems, air pollution episode cycles and management of control. A selected list of 11ASA and WHO/EURO publications related to air pollution is included. Separate abstracts were prepared for 15 papers in this book.

  14. Air Quality and Climate Change

    International Nuclear Information System (INIS)

    Colette, A.; Rouil, L.; Bessagnet, B.; Schucht, S.; Szopa, S.; Vautard, R.; Menut, L.

    2013-01-01

    Climate change and air quality are closely related: through the policy measures implemented to mitigate these major environmental threats but also through the geophysical processes that drive them. We designed, developed and implemented a comprehensive regional air quality and climate modeling System to investigate future air quality in Europe taking into account the combined pressure of future climate change and long range transport. Using the prospective scenarios of the last generation of pathways for both climate change (emissions of well mixed greenhouse gases) and air pollutants, we can provide a quantitative view into the possible future air quality in Europe. We find that ozone pollution will decrease substantially under the most stringent scenario but the efforts of the air quality legislation will be adversely compensated by the penalty of global warming and long range transport for the business as usual scenario. For particulate matter, the projected reduction of emissions efficiently reduces exposure levels. (authors)

  15. Improving and monitoring air quality.

    Science.gov (United States)

    DuPont, André

    2018-05-01

    Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.

  16. Air ions and aerosol science

    International Nuclear Information System (INIS)

    Tammet, H.

    1996-01-01

    Collaboration between Gas Discharge and Plasma Physics, Atmospheric Electricity, and Aerosol Science is a factor of success in the research of air ions. The concept of air ion as of any carrier of electrical current through the air is inherent to Atmospheric Electricity under which a considerable statistical information about the air ion mobility spectrum is collected. A new model of air ion size-mobility correlation has been developed proceeding from Aerosol Science and joining the methods of neighboring research fields. The predicted temperature variation of the mobility disagrees with the commonly used Langevin rule for the reduction of air ion mobilities to the standard conditions. Concurrent errors are too big to be neglected in applications. The critical diameter distinguishing cluster ions and charged aerosol particles has been estimated to be 1.4 endash 1.8 nm. copyright 1996 American Institute of Physics

  17. Low cost solar air heater

    International Nuclear Information System (INIS)

    Gill, R.S.; Singh, Sukhmeet; Singh, Parm Pal

    2012-01-01

    Highlights: ► Single glazed low cost solar air heater is more efficient during summer while double glazed is better in winter. ► For the same initial investment, low cost solar air heaters collect more energy than packed bed solar air heater. ► During off season low cost solar air heater can be stored inside as it is light in weight. - Abstract: Two low cost solar air heaters viz. single glazed and double glazed were designed, fabricated and tested. Thermocole, ultraviolet stabilised plastic sheet, etc. were used for fabrication to reduce the fabrication cost. These were tested simultaneously at no load and with load both in summer and winter seasons along with packed bed solar air heater using iron chips for absorption of radiation. The initial costs of single glazed and double glazed are 22.8% and 26.8% of the initial cost of packed bed solar air heater of the same aperture area. It was found that on a given day at no load, the maximum stagnation temperatures of single glazed and double glazed solar air heater were 43.5 °C and 62.5 °C respectively. The efficiencies of single glazed, double glazed and packed bed solar air heaters corresponding to flow rate of 0.02 m 3 /s-m 2 were 30.29%, 45.05% and 71.68% respectively in winter season. The collector efficiency factor, heat removal factor based on air outlet temperature and air inlet temperature for three solar air heaters were also determined.

  18. Air and metal hydride battery

    Energy Technology Data Exchange (ETDEWEB)

    Lampinen, M.; Noponen, T. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Applied Thermodynamics

    1998-12-31

    The main goal of the air and metal hydride battery project was to enhance the performance and manufacturing technology of both electrodes to such a degree that an air-metal hydride battery could become a commercially and technically competitive power source for electric vehicles. By the end of the project it was possible to demonstrate the very first prototype of the air-metal hydride battery at EV scale, achieving all the required design parameters. (orig.)

  19. Indigenous high volume air sampler

    International Nuclear Information System (INIS)

    Kotrappa, P.; Setty, N.P.N.; Raghunath, B.; Sivasubrahmanyam, P.S.

    1978-01-01

    A high volume air sampler for use in assessing concentrations of low levels of air borne particulates has been fabricated. The sampler will be of use in radioactive installations, conventional industries and environmental pollution analysis. It is comparable in performance with the imported Staplex air samplers. A turbine and motor system similar to the one found in conventional vacuum cleaners is used in its design. The sampler units can be produced in large numbers. (M.G.B.)

  20. Natural Flow Air Cooled Photovoltaics

    Science.gov (United States)

    Tanagnostopoulos, Y.; Themelis, P.

    2010-01-01

    Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. Our experimental study aims to investigate the improvement in the electrical performance of a photovoltaic installation on buildings through cooling of the photovoltaic panels with natural air flow. We performed experiments using a prototype based on three silicon photovoltaic modules placed in series to simulate a typical sloping building roof with photovoltaic installation. In this system the air flows through a channel on the rear side of PV panels. The potential for increasing the heat exchange from the photovoltaic panel to the circulating air by the addition of a thin metal sheet (TMS) in the middle of air channel or metal fins (FIN) along the air duct was examined. The operation of the device was studied with the air duct closed tightly to avoid air circulation (CLOSED) and the air duct open (REF), with the thin metal sheet (TMS) and with metal fins (FIN). In each case the experiments were performed under sunlight and the operating parameters of the experimental device determining the electrical and thermal performance of the system were observed and recorded during a whole day and for several days. We collected the data and form PV panels from the comparative diagrams of the experimental results regarding the temperature of solar cells, the electrical efficiency of the installation, the temperature of the back wall of the air duct and the temperature difference in the entrance and exit of the air duct. The comparative results from the measurements determine the improvement in electrical performance of the photovoltaic cells because of the reduction of their temperature, which is achieved by the naturally circulating air.

  1. Air pollution: Impact and prevention

    OpenAIRE

    SIERRA-VARGAS, MARTHA PATRICIA; TERAN, LUIS M

    2012-01-01

    ABSTRACT Air pollution is becoming a major health problem that affects millions of people worldwide. In support of this observation, the World Health Organization estimates that every year, 2.4 million people die because of the effects of air pollution on health. Mitigation strategies such as changes in diesel engine technology could result in fewer premature mortalities, as suggested by the US Environmental Protection Agency. This review: (i) discusses the impact of air pollution on respirat...

  2. Air pollution control in practice

    International Nuclear Information System (INIS)

    Baum, F.

    1988-01-01

    The book offers a comprehensive treatment of the subject, from air pollution monitoring and effects on human and animal health, on plants and materials, to pollution reduction measures, practical applications, and legal regulations. It intends to give the air pollution expert a basis for developing practicable solutions. Apart from the 'classic' pollutants, also radioactive air pollution is gone into. (DG) With 366 figs., 190 tabs [de

  3. Theatre Review | Various Authors | Shakespeare in Southern Africa

    African Journals Online (AJOL)

    Twelfth Night: The Port Elizabeth Shakespearean Festival, February 2004; Macbeth: Directed by Geoffrey Hyland, Maynardville Open Air Theatre, January to. February 2004; The Marowitz Hamlet: Directed by Floyed de Vaal for the University of. Stellenbosch Drama Department, July 2004; Bollywood Twelfth Night: Steven ...

  4. Air climate health

    International Nuclear Information System (INIS)

    Duval, Dominique; Riottot, Michel; Leger, Karine

    2015-01-01

    'France Nature Environnement Ile de France' publishes, on occasion of the COP 21, a special paper about the air pollution in the Paris region, greenhouse gases and their influence on the environment. This document has been written in close cooperation with professionals and civil associations. Elected representatives from local and regional authorities also speak about their experiences. The first part emphasizes the urgency to accelerate preventive and corrective measures since the air pollution, after slightly decreasing in the 2000's, remains stable. Our work is a science based analysis of essential parameters and details the impact of local pollution and greenhouse gases on the climate. It is based on the GIEC 2013 and 2015 reports, as well as the work of National meteorology in association with the Climate agency of Paris. The threshold of not exceeding an average temperature of +2 deg. C in 2100 is almost reached. If consumption of fossil energies does not heavily decline in the next 10 years, the earth's thermal machine will enter, for several centuries, into an uncontrollable cycle which could endanger life on earth with average temperatures exceeding 4 to 6 deg. C above the current level. The second part reveals the impact of air pollution on the health of the Paris region's population, especially on women who are the most affected by respiratory diseases: obstructive pulmonary bronchitis and asthma. Four departments are particularly affected: Paris, Seine-et-Marne, Seine-Saint-Denis and Val-d'Oise. Even though we do not have the formal causal proof between gas concentration and disease, analysis of similar situations worldwide eliminate any doubts about the reality of the relationship. The third part proposes solutions which can be implemented by local government, companies, but also civil associations and citizens in order to quickly decrease greenhouse gas production. Solutions range from energy sobriety to change in travel

  5. Air effect on polycarbonate radiolysis

    International Nuclear Information System (INIS)

    Terence, Mauro C.; Araujo, Elmo S.; Guedes, Selma M.L.

    1995-01-01

    The formation and decay of radicals in the radiolysis of new type of polycarbonate (G scission = 0,73) was investigated by electron spin resonance spectroscopy in the presence and absence of air at room temperature. The air does not interfere in the formation of radicals because they are formed as consequence of direct interaction of radiation. But the air interferes in their decays. During the irradiation the air reacts with all isopropyl radicals and with 2/3 of phenoxy + phenyl radicals. (author). 5 refs., 3 figs

  6. Air Quality at Your Street

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Becker, Thomas; Ketzel, Matthias

    Citizens are frequently concerned about the air quality where they live, where they go to work, where their children go to kindergarten or where they want to move to. Municipalities may also have an interest in location based air quality information e.g. in relation to screening of complaints from...... concerned citizents, or in the context of localization of institutions, etc. The purpose of the project ‘Air Quality at Your Street’ is to create interactive air quality maps on the internet using webGIS to illustrate the geographical variation of air quality in Denmark for selected health related air...... pollutants. The maps show annual means of NO2, PM2.5 or PM10 for 2012. The user interface presents modelled air quality data on a map where the user can select map view, pan, zoom in and out, etc. It is also possible to get the air quality for a particular address by entering a specific address. Air quality...

  7. Indoor Air Quality in Schools

    Science.gov (United States)

    This web site will educate the public about indoor environmental issues specific to educational facilities and the importance of developing and sustaining comprehensive indoor air quality management programs.

  8. Air movement - good or bad?

    DEFF Research Database (Denmark)

    Toftum, Jørn

    2004-01-01

    when air movement is desirable and when it is not. At temperatures up to 22-23oC, at sedentary activity and with occupants feeling neutral or cooler there is a risk of air movement being perceived as unacceptable, even at low velocities. In particular, a cool overall thermal sensation negatively...... influences the subjective perception of air movement. With occupants feeling warmer than neutral, at temperatures above 23oC or at raised activity levels, humans generally do not feel draught at air velocities typical for indoor environments (up to around 0.4 m/s). In the higher temperature range, very high...

  9. metropolitana en Buenos Aires

    Directory of Open Access Journals (Sweden)

    Pedro Pírez

    2006-01-01

    Full Text Available In this paper, we present a description of some concrete processes that made up the transformations in the metropolitan configuration and functioning in Buenos Aires in the 1990s during the 20th Century. We are referring to components related to the impact of processes at the macro level (national and international pertaining to restructuring and globalisation. We aim to understand the “forces” that mediate between the global and the local arenas, identifying the actors and the relationships behind metropolitan changes as well as searching for the meaning that the city acquires and which is understood as “privatisation”. In the first section of the paper, this concept is made explicit.

  10. Change in the air

    International Nuclear Information System (INIS)

    Marshall, C.

    1999-01-01

    Aviation has a key part to play in the future protection of the environment. Such issues as climate change raise serious questions for all of us, but particularly for energy-intensive industries such as aviation, which makes a small but identifiable contribution to man's impact on the global climate. Airlines, such as British Airways, must strive to meet ever-higher standards of environmental performance. Environmental challenges facing the aviation industry are categorized as: noise, emissions and fuel efficiency, waste of energy, water and material, congestion in the air and on the ground, tourism and conservation. These headings have proved to be robust and our environmental programmes have, accordingly, been deployed under them

  11. Air pollution test methods

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, E; Sugano, S; Fukui, S

    1974-06-01

    Vanadium exists in heavy oil as a chelate with mesoporphiline methyl ester, and the combustion ash of the oil may contain up to 80 percent of its oxides. Air is sampled in a standard way and to each 50 ml of the sample and blank solutions, add 5 ml of phosphoric acid and 2 ml of 10 percent ammonium sulfamate solution. After 10 min, the solution is titrated with potassium permanganate until it becomes purple. Two ml of hydrochloric acid and 10 ml of N-benzoylphenylhydroxylamine benzene solution are added and shaken for 30 sec. The benzene layer is washed with several portions of 2 ml HCl until no coloration of the HCl solution is visible. The benzene layer is transferred to a colorimetric tube and dried with granular calcium chloride. The absorbance is measured near 530 nm and the concentration is determined from a calibration curve previously prepared.

  12. Comparison of personal air samplers and static air samplers

    International Nuclear Information System (INIS)

    Carter, M.W.; Lumsden, B.

    1979-01-01

    The authors demonstrate that radioactive air contamination levels calculated from PAS results will always be higher than air contamination levels calculated from SAS results, other conditions being equal. The most probable explanation seems to be in a relationship between the sampling velocity and the particle size of the dust sampled

  13. Clearing the air. Air quality modelling for policy support

    NARCIS (Netherlands)

    Hendriks, C.

    2017-01-01

    The studies presented in this thesis were performed to provide policy makers with more accurate information about the sources of air pollution and the possible consequences of future developments on air quality. This enables policy makers to make better informed decisions when formulating policies

  14. Air Quality | Air Quality Planning & Standards | US EPA

    Science.gov (United States)

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  15. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  16. Danger in the Air: Air Pollution and Cognitive Dysfunction.

    Science.gov (United States)

    Cipriani, Gabriele; Danti, Sabrina; Carlesi, Cecilia; Borin, Gemma

    2018-01-01

    Clean air is considered to be a basic requirement for human health and well-being. To examine the relationship between cognitive performance and ambient pollution exposure. Studies were identified through a systematic search of online scientific databases, in addition to a manual search of the reference lists from the identified papers. Air pollution is a multifaceted toxic chemical mixture capable of assaulting the central nervous system. Despite being a relatively new area of investigation, overall, there is mounting evidence implicating adverse effects of air pollution on cognitive function in both adults and children. Consistent evidence showed that exposure to air pollution, specifically exposure to particulate matter, caused poor age-related cognitive performance. Living in areas with high levels of air pollution has been linked to markers of neuroinflammation and neuropathology that are associated with neurodegenerative conditions such as Alzheimer's disease-like brain pathologies.

  17. Ozone as an air pollutant

    DEFF Research Database (Denmark)

    Berg, Rolf W.

    1996-01-01

    A Danish new book on ozone as an air pollutant has been reviewed. The Book is "Ozon som luftforurening" by Jes Fenger, Published by "Danmarks Miljøundersøgelser, 1995.......A Danish new book on ozone as an air pollutant has been reviewed. The Book is "Ozon som luftforurening" by Jes Fenger, Published by "Danmarks Miljøundersøgelser, 1995....

  18. The Federal Air Pollution Program.

    Science.gov (United States)

    National Air Pollution Control Administration (DHEW), Washington, DC.

    Described is the Federal air pollution program as it was in 1967. The booklet is divided into these major topics: History of the Federal Program; Research; Assistance to State and Local Governments; Abatement and Prevention of Air Pollution; Control of Motor Vehicle Pollution; Information and Education; and Conclusion. Federal legislation has…

  19. A Breath of Fresh Air

    Science.gov (United States)

    Belew, Rachel

    2011-01-01

    One of the most important aspects of a healthy school--and one that, unfortunately, often falls by the wayside--is indoor air quality. The U.S. Government Accountability Office estimates that more than 15,000 schools nationwide report suffering from poor indoor air quality. According to the U.S. Environmental Protection Agency, schools with poor…

  20. The NRL MITE Air Vehicle

    National Research Council Canada - National Science Library

    Kellogg, James; Bovais, Christopher; Dahlburg, Jill; Foch, Richard; Gardner, John; Gordon, Diana; Hartley, Ralph; Kamgar-Parsi, Behrooz; McFarlane, Hugh; Pipitone, Frank; Ramamurti, Ravi; Sciambi, Adam; Spears, William; Srull, Donald; Sullivan, Carol

    2001-01-01

    .... The NRL Micro Tactical Expendable "MITE" air vehicle is a result of this research. The operational MITE is a hand-launched, dual-propeller, fixed-wing air vehicle, with a 9-inch chord and a wingspan of 8 to 18 inches, depending on payload weight...

  1. Radioactive wastes in the air

    International Nuclear Information System (INIS)

    1968-01-01

    Methods of preventing the pollution of air by radioactive waste from atomic centres were discussed in an Agency Symposium held in New York at the end of August. It was agreed that the atomic industry has a good safety record, and suggestions were made that there should now be a concerted effort to prevent air pollution by all industries. (author)

  2. Mind Your Indoor Air Quality

    Science.gov (United States)

    Mak, Lily

    2012-01-01

    When it comes to excelling in the classroom, it turns out the air students are breathing is just as important as the lessons they are learning. Studies show poor indoor air quality (IAQ) can lessen the comfort of students as well as staff--affecting concentration, attendance and student performance. It can even lead to lower IQs. What's more, poor…

  3. State of the Air 2015

    Science.gov (United States)

    ... Select Your State Health Risks Ozone Particle Pollution Children’s Health Disparities & Near Highways Protect Yourself Our Fight What We Do Our Story Personal Stories Clean Air Timeline Take Action Press Materials Press Releases Web Banners Social Media What's the State of Your Air ? Home > 2015 > ...

  4. Air barrier systems: Construction applications

    Energy Technology Data Exchange (ETDEWEB)

    Perrault, J.C

    1989-01-01

    An examination is presented of how ordinary building materials can be used in an innovative manner to design, detail, and construct effective air barrier systems for common types of walls. For residential construction, the air drywall approach uses the interior gypsum board as the main component of the wall air barrier system. Joints between the gypsum board and adjacent materials or assemblies are sealed by gaskets. In commercial construction, two different techniques are employed for using gypsum board as air barrier material: the accessible drywall and non-accessible drywall approaches. The former is similar to the air drywall approach except that high performance sealants are used instead of gaskets. In the latter approach, exterior drywall sheathing is the main component of the air barrier system; joints between boards are taped and joints between boards and other components are sealed using elastomeric membrane strips. For various types of commercial and institutional buildings, metal air barrier systems are widely used and include pre-engineered curtain walls or sheet metal walls. Masonry wall systems are regarded as still the most durable, fireproof, and soundproof wall type available but an effective air barrier system has typically been difficult to implement. Factory-made elastomeric membranes offer the potential to provide airtightness to masonry walls. These membranes are applied on the entire masonry wall surface and are used to make airtight connections with other building components. Two types of product are available: thermofusible and peel-and-stick membranes. 5 figs.

  5. Air Pollution and Human Health

    Science.gov (United States)

    Lave, Lester B.; Seskin, Eugene P.

    1970-01-01

    Reviews studies statistically relating air pollution to mortality and morbidity rates for respiratory, and cardiovascular diseases, cancer and infant mortality. Some data recalculated. Estimates 50 percent air pollution reduction will save 4.5 percent (2080 million dollars per year) of all economic loss (hospitalization, income loss) associated…

  6. Population Dynamics and Air Pollution

    DEFF Research Database (Denmark)

    Flachs, Esben Meulengracht; Sørensen, Jan; Bønløkke, Jacob

    2013-01-01

    Objective. To explore how three different assumptions on demographics affect the health impact of Danish emitted air pollution in Denmark from 2005 to 2030, with health impact modeled from 2005 to 2050. Methods. Modeled air pollution from Danish sources was used as exposure in a newly developed......) a static year 2005 population, (2) morbidity and mortality fixed at the year 2005 level, or (3) an expected development. Results. The health impact of air pollution was estimated at 672,000, 290,000, and 280,000 lost life years depending on demographic assumptions and the corresponding social costs at 430.......4 M€, 317.5 M€, and 261.6 M€ through the modeled years 2005–2050. Conclusion. The modeled health impact of air pollution differed widely with the demographic assumptions, and thus demographics and assumptions on demographics played a key role in making health impact assessments on air pollution....

  7. Atmospheric Chemistry and Air Pollution

    Directory of Open Access Journals (Sweden)

    Jeffrey S. Gaffney

    2003-01-01

    Full Text Available Atmospheric chemistry is an important discipline for understanding air pollution and its impacts. This mini-review gives a brief history of air pollution and presents an overview of some of the basic photochemistry involved in the production of ozone and other oxidants in the atmosphere. Urban air quality issues are reviewed with a specific focus on ozone and other oxidants, primary and secondary aerosols, alternative fuels, and the potential for chlorine releases to amplify oxidant chemistry in industrial areas. Regional air pollution issues such as acid rain, long-range transport of aerosols and visibility loss, and the connections of aerosols to ozone and peroxyacetyl nitrate chemistry are examined. Finally, the potential impacts of air pollutants on the global-scale radiative balances of gases and aerosols are discussed briefly.

  8. Air pollution: impact and prevention.

    Science.gov (United States)

    Sierra-Vargas, Martha Patricia; Teran, Luis M

    2012-10-01

    Air pollution is becoming a major health problem that affects millions of people worldwide. In support of this observation, the World Health Organization estimates that every year, 2.4 million people die because of the effects of air pollution on health. Mitigation strategies such as changes in diesel engine technology could result in fewer premature mortalities, as suggested by the US Environmental Protection Agency. This review: (i) discusses the impact of air pollution on respiratory disease; (ii) provides evidence that reducing air pollution may have a positive impact on the prevention of disease; and (iii) demonstrates the impact concerted polices may have on population health when governments take actions to reduce air pollution. © 2012 The Authors. Respirology © 2012 Asian Pacific Society of Respirology.

  9. 22 CFR 228.22 - Air transportation.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Air transportation. 228.22 Section 228.22... for USAID Financing § 228.22 Air transportation. (a) The eligibility of air transportation is... U.S. flag air carriers for all international air travel and transportation, unless such service is...

  10. Large scale air monitoring: Biological indicators versus air particulate matter

    International Nuclear Information System (INIS)

    Rossbach, M.; Jayasekera, R.; Kniewald, G.

    2000-01-01

    Biological indicator organisms are widely used for monitoring and banking purposes since many years. Although the complexity of the interactions between bioorganisms and their environment is generally not easily comprehensible, environmental quality assessment using the bioindicator approach offers some convincing advantages compared to direct analysis of soil, water, or air. Direct measurement of air particulates is restricted to experienced laboratories with access to expensive sampling equipment. Additionally, the amount of material collected generally is just enough for one determination per sampling and no multidimensional characterization might be possible. Further, fluctuations in air masses have a pronounced effect on the results from air filter sampling. Combining the integrating property of bioindicators with the world wide availability and uniform matrix characteristics of air particulates as a prerequisite for global monitoring of air pollution will be discussed. A new approach for sampling urban dust using large volume filtering devices installed in air conditioners of large hotel buildings is assessed. A first experiment was initiated to collect air particulates (300 to 500 g each) from a number of hotels during a period of three to four months by successive vacuum cleaning of used inlet filters from high volume air conditioning installations reflecting average concentrations per three months in different large cities. This approach is expected to be upgraded and applied for global monitoring. Highly positive correlated elements were found in lichen such as K/S, Zn/P, the rare earth elements (REE) and a significant negative correlation between Fig and Cu was observed in these samples. The ratio of concentrations of elements in dust and Usnea spp. is highest for Cr, Zn, and Fe (400-200) and lowest for elements such as Ca, Rb, and Sr (20-10). (author)

  11. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  12. Indoor air humidity, air quality, and health - An overview.

    Science.gov (United States)

    Wolkoff, Peder

    2018-04-01

    There is a long-standing dispute about indoor air humidity and perceived indoor air quality (IAQ) and associated health effects. Complaints about sensory irritation in eyes and upper airways are generally among top-two symptoms together with the perception "dry air" in office environments. This calls for an integrated analysis of indoor air humidity and eye and airway health effects. This overview has reviewed the literature about the effects of extended exposure to low humidity on perceived IAQ, sensory irritation symptoms in eyes and airways, work performance, sleep quality, virus survival, and voice disruption. Elevation of the indoor air humidity may positively impact perceived IAQ, eye symptomatology, and possibly work performance in the office environment; however, mice inhalation studies do not show exacerbation of sensory irritation in the airways by low humidity. Elevated humidified indoor air appears to reduce nasal symptoms in patients suffering from obstructive apnea syndrome, while no clear improvement on voice production has been identified, except for those with vocal fatigue. Both low and high RH, and perhaps even better absolute humidity (water vapor), favors transmission and survival of influenza virus in many studies, but the relationship between temperature, humidity, and the virus and aerosol dynamics is complex, which in the end depends on the individual virus type and its physical/chemical properties. Dry and humid air perception continues to be reported in offices and in residential areas, despite the IAQ parameter "dry air" (or "wet/humid air") is semantically misleading, because a sensory organ for humidity is non-existing in humans. This IAQ parameter appears to reflect different perceptions among other odor, dustiness, and possibly exacerbated by desiccation effect of low air humidity. It is salient to distinguish between indoor air humidity (relative or absolute) near the breathing and ocular zone and phenomena caused by moisture

  13. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  14. Analysis of air safety in the European system of air traffic

    Directory of Open Access Journals (Sweden)

    О.Є. Луппо

    2008-04-01

    Full Text Available  Article describes air traffic safety provision requirements in the Air Traffic Management system of Europe. Consideration of air traffic variation which affecting the air traffic management operations have been reviewed.

  15. Problem of air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Berge, H

    1964-01-01

    The effects of air pollutants on plants are dependent on and modified by climatic, orographic, edaphic, and biotic factors; the synergism of pollutants; and differences in the sensitivity of individual plants and species. Sulfur dioxide and fluorine are the most dangerous pollutants for plants, but ammonia, hydrogen sulfide, nitrogen oxides, nitric acid, chlorine, hydrochloric acid, bromine, iodine, hydrocyanic acid, ethylene, carbon monoxide, hydrocarbons, mercaptans, asphalt and tar vapors, mercury, and selenium can also inflict damage. Young leaves, sensitive to H/sub 2/S, nitrogen oxides, Cl, HCl, HCN, mercaptans, Hg, and sulfuric acid, are more resistant to SO/sub 2/, gaseous F compounds, ethylene, and selenium than older leaves. Damage is most serious when pollutants enter leaves simultaneously or alternately through epidermis and stomata. The yellow-to-brown coloration of leaves is usually a result of the precipitation of tanning. Plasmolysis is caused by SO/sub 2/, gaseous F compounds, ammonia, nitrogen oxides, HNO/sub 3/, Br, asphalt and tar vapors, while photosynthesis is stimulated by traces of ammonia, HNO/sub 3/, and saturated hydrocarbons. Increased transpiration due to SO/sub 2/ and HCl and elevated permeability and osmosis due to SO/sub 2/ were observed. 9 references, 12 figures, 1 table.

  16. Writing in turbulent air.

    Science.gov (United States)

    Bominaar, Jeroen; Pashtrapanska, Mira; Elenbaas, Thijs; Dam, Nico; ter Meulen, Hans; van de Water, Willem

    2008-04-01

    We describe a scheme of molecular tagging velocimetry in air in which nitric oxide (NO) molecules are created out of O2 and N2 molecules in the focus of a strong laser beam. The NO molecules are visualized a while later by laser-induced fluorescence. The precision of the molecular tagging velocimetry of gas flows is affected by the gradual blurring of the written patterns through molecular diffusion. In the case of turbulent flows, molecular diffusion poses a fundamental limit on the resolution of the smallest scales in the flow. We study the diffusion of written patterns in detail for our tagging scheme which, at short (micros) delay times is slightly anomalous due to local heating by absorption of laser radiation. We show that our experiments agree with a simple convection-diffusion model that allows us to estimate the temperature rise upon writing. Molecular tagging can be a highly nonlinear process, which affects the art of writing. We find that our tagging scheme is (only) quadratic in the intensity of the writing laser.

  17. Breathe the air!

    CERN Multimedia

    2003-01-01

    Feeling a bit cooped up in your office? Want to share your interest in science and technology with others but your computer's heard it all before and your colleagues won't even listen anymore? Then here's the answer - come and get some fresh air with the Education and Communication Group. The Visits Service and the Press Office offer you the opportunity to come into contact with CERN visitors. - Be a guide! In becoming a guide you get the opportunity to introduce the Laboratory to vast array of visitors of all nationalities and ages and communicate to them your passion for science and technology. You can get involved as a CERN guide on various levels - giving presentations and tours of the Laboratory, but also leading a «Drôle de Physique» workshop and giving tours of Microcosm. Guides receive training. If you're interested, take a look at the Guides Homepage where all the relevant information and formalities are explained: http://www.cern.ch/guides See also the article in the Bulletin n°25/2002. - Fa...

  18. Air pollution in Copenhagen

    International Nuclear Information System (INIS)

    Flyger, H.; Palmgren Jensen, F.; Kemp, K.

    1976-03-01

    Aerosols were monitored in Greater Copenhagen in the period June 1973 to July 1974. Size-fractionated cascade impactor samples and unfractionated filter samples were regularly collected and analyzed be neutron activation analysis, spark emission spectroscopy or proton-induced X-ray emission spectroscopy. Concentrations were determined of the following elements: Al, Si, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Mo, Cd, Sn, Sb, and Pb. All elements showed orders-of-magnitude fluctuationsthe mean concentrations were roughly the same as in other large cities. In relation to proposed air quality standards, Pb was the most critical component. Statistical analysis of variation patterns, size distributions and interelement correlations indicate that automotive exhaust is the source of Br and Pbfuel-oil combustion is the main source of V and Ni (and partly of S)soil dust raised by wind or by human activity (e.g. traffic) is the main source of Al, Si, Ca, Ti, and Fe. (author)

  19. Air Pollution Forecasts: An Overview

    Science.gov (United States)

    Bai, Lu; Wang, Jianzhou; Lu, Haiyan

    2018-01-01

    Air pollution is defined as a phenomenon harmful to the ecological system and the normal conditions of human existence and development when some substances in the atmosphere exceed a certain concentration. In the face of increasingly serious environmental pollution problems, scholars have conducted a significant quantity of related research, and in those studies, the forecasting of air pollution has been of paramount importance. As a precaution, the air pollution forecast is the basis for taking effective pollution control measures, and accurate forecasting of air pollution has become an important task. Extensive research indicates that the methods of air pollution forecasting can be broadly divided into three classical categories: statistical forecasting methods, artificial intelligence methods, and numerical forecasting methods. More recently, some hybrid models have been proposed, which can improve the forecast accuracy. To provide a clear perspective on air pollution forecasting, this study reviews the theory and application of those forecasting models. In addition, based on a comparison of different forecasting methods, the advantages and disadvantages of some methods of forecasting are also provided. This study aims to provide an overview of air pollution forecasting methods for easy access and reference by researchers, which will be helpful in further studies. PMID:29673227

  20. Air Pollution Forecasts: An Overview.

    Science.gov (United States)

    Bai, Lu; Wang, Jianzhou; Ma, Xuejiao; Lu, Haiyan

    2018-04-17

    Air pollution is defined as a phenomenon harmful to the ecological system and the normal conditions of human existence and development when some substances in the atmosphere exceed a certain concentration. In the face of increasingly serious environmental pollution problems, scholars have conducted a significant quantity of related research, and in those studies, the forecasting of air pollution has been of paramount importance. As a precaution, the air pollution forecast is the basis for taking effective pollution control measures, and accurate forecasting of air pollution has become an important task. Extensive research indicates that the methods of air pollution forecasting can be broadly divided into three classical categories: statistical forecasting methods, artificial intelligence methods, and numerical forecasting methods. More recently, some hybrid models have been proposed, which can improve the forecast accuracy. To provide a clear perspective on air pollution forecasting, this study reviews the theory and application of those forecasting models. In addition, based on a comparison of different forecasting methods, the advantages and disadvantages of some methods of forecasting are also provided. This study aims to provide an overview of air pollution forecasting methods for easy access and reference by researchers, which will be helpful in further studies.

  1. Air Pollution Forecasts: An Overview

    Directory of Open Access Journals (Sweden)

    Lu Bai

    2018-04-01

    Full Text Available Air pollution is defined as a phenomenon harmful to the ecological system and the normal conditions of human existence and development when some substances in the atmosphere exceed a certain concentration. In the face of increasingly serious environmental pollution problems, scholars have conducted a significant quantity of related research, and in those studies, the forecasting of air pollution has been of paramount importance. As a precaution, the air pollution forecast is the basis for taking effective pollution control measures, and accurate forecasting of air pollution has become an important task. Extensive research indicates that the methods of air pollution forecasting can be broadly divided into three classical categories: statistical forecasting methods, artificial intelligence methods, and numerical forecasting methods. More recently, some hybrid models have been proposed, which can improve the forecast accuracy. To provide a clear perspective on air pollution forecasting, this study reviews the theory and application of those forecasting models. In addition, based on a comparison of different forecasting methods, the advantages and disadvantages of some methods of forecasting are also provided. This study aims to provide an overview of air pollution forecasting methods for easy access and reference by researchers, which will be helpful in further studies.

  2. Air quality management in Botswana

    Directory of Open Access Journals (Sweden)

    Modupe O. Akinola

    2017-06-01

    Full Text Available This paper examines air pollution situation and the history of air quality management in Botswana. The current air quality management in Botswana is still largely underpinned by the Atmospheric Pollution Prevention Act of 1971, supplemented by the more recently enacted legislations such as the Environmental Impact Assessment (EIA Act of 2010 and the Ambient Air Quality - Limits for Common Pollutants of 2012 published by the Botswana Bureau of Standards. Though commendable efforts have been made toward legislating against air and other forms of pollution, these have not yielded expected results in view of the prevailing levels of air pollutants like sulphur dioxide and fine particulate matters in the country’s atmospheric environment. Legislation as a sole measure may not be effective in tackling this challenge. Rather, government should also address some root-causes of the problem by making policies and programmes that will reduce unemployment and increase the earning capacity of citizenry. This will, among other things, effectively check poverty-induced biomass burning in the country. The paper looks at some other challenges of air pollution management and suggestions are made to tackle the identified problems.

  3. Profit goal set for airBaltic

    Index Scriptorium Estoniae

    2011-01-01

    Latvijas Krajbanka president arvab, et airBalticu olukorra stabiliseerimiseks läheb vähemalt aasta. AirBalticu senine juht Bertolt Flick võib hakata uue Vilniuse lennukompanii investoriks. AirBalticu uuest juhatusest

  4. Towards a Flexible Theater Air Warfare Doctrine

    National Research Council Canada - National Science Library

    Gunzinger, Mark A

    1996-01-01

    "Billy Mitchell was right." These words hung in the foyer of the Air Force Air Command and Staff College during Desert Storm, reflecting the belief that air power had finally come of age in the skies over Iraq...

  5. Civil Air Patrol (CAP) Aircraft Requirement Study

    National Research Council Canada - National Science Library

    Mercher, Christopher

    1999-01-01

    The Air Force Audit Agency (AFAA) concluded in its Report of Audit EB0980013 (13 May 98), Air Force Oversight of CY 1996 Civil Air Patrol Corporation Activities, CAP-USAF, Maxwell AFB, AL 36112-6323...

  6. Historical Ambient Air Quality Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Historical Ambient Air Quality Data Inventory contains measured and estimated data on ambient air pollution for use in assessing air quality, assisting in...

  7. Responses of plants to air pollution

    National Research Council Canada - National Science Library

    Mudd, J. Brian; Kozlowski, T. T

    1975-01-01

    .... KOZLOWSKI Pollution, 1975 ELROY L. RICE. Allelopathy, (Eds.). Fire and Ecosystems, 1974 (Eds.). Responses of Plants to Air Responses of Plants to Air PollutionRESPONSES OF PLANTS TO AIR POLLUTION E...

  8. Air University Style and Author Guide

    National Research Council Canada - National Science Library

    Bassett, Marvin

    2005-01-01

    The "Air University Style and Author Guide" is designed to unify the writing of faculty, staff, and students of Air University stylistically, and to give them information about publishing with Air University (AU) Press...

  9. High Altitude Clear Air Turbulence Project

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Air Force Flight Dynamics Laboratory conducted the High Altitude Clear Air Turbulence Project in the mid 1960s with the intention of better understanding air...

  10. National Air Toxic Assessments (NATA) Results

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Air Toxics Assessment was conducted by EPA in 2002 to assess air toxics emissions in order to identify and prioritize air toxics, emission source types...

  11. The Warfighting Capacity of Air Combat Command's Numbered Air Forces

    National Research Council Canada - National Science Library

    Hanser, Lawrence

    2000-01-01

    ...) of the Air Combat Command (ACC), General Richard E. Hawley, the ACC Commander, asked if RAND could offer an analysis of the number of NAFs that were needed by ACC to meet warfighting requirements...

  12. Managing Air Quality - Control Strategies to Achieve Air Pollution Reduction

    Science.gov (United States)

    Considerations in designing an effective control strategy related to air quality, controlling pollution sources, need for regional or national controls, steps to developing a control strategy, and additional EPA resources.

  13. Air leakage control in chief tunnel of uranium mines using air screen

    International Nuclear Information System (INIS)

    Xiao Gengsheng

    1987-01-01

    In this paper the results of air leakage control are described using air screen in the chief tunnels of some uranium mines. The air leakage decreases by 79-91% after using air screen. On the basis of mathematical treatment, the formulas for calculating the air resistance efficiency of air screen are presented

  14. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    DEFF Research Database (Denmark)

    Skwarczynski, Mariusz; Melikov, Arsen Krikor; Kaczmarczyk, J.

    2010-01-01

    and local air velocity under a constant air temperature of 26 degrees C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front...

  15. 14 CFR 399.86 - Payments for non-air transportation services for air cargo.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Payments for non-air transportation... Enforcement § 399.86 Payments for non-air transportation services for air cargo. The Board considers that... air carriers for non-air transportation preparation of air cargo shipments are for services ancillary...

  16. 14 CFR 234.13 - Reports by air carriers on incidents involving animals during air transport.

    Science.gov (United States)

    2010-01-01

    ... involving animals during air transport. 234.13 Section 234.13 Aeronautics and Space OFFICE OF THE SECRETARY... REPORTS § 234.13 Reports by air carriers on incidents involving animals during air transport. (a) Any air... during air transport provided by the air carrier. (b) The report shall be made in the form and manner set...

  17. Air quality indices : a review

    International Nuclear Information System (INIS)

    Hewings, J.

    2001-10-01

    Pollution Probe presents some background information that will help in the development of a national Air Quality Index (AQI) in Canada. This report examines the issues that should be addressed in revising the national Index of the Quality of Air (IQUA) or creating a new national Air Quality Index. The IQUA was devised in 1976 and provides Canadians with real-time information on the state of community air quality by including major pollutants and their synergies. It is currently being used for air quality management plans and air quality alert systems. At the same time that the IQUA was devised, the United States Environmental Protection Agency (US EPA) produced a parallel air quality index known as the Pollution Standard Index (PSI) which incorporated 5 criteria pollutants (particulate matter, sulphur dioxide, carbon monoxide, nitrogen oxide and ground level ozone) for which national health-based standards were devised. In 1999, the US EPA renamed their index the Air Quality Index (AQI) and made revisions to the primary health-based national ambient air quality standards for ground-level ozone and particulate matter. Separate values for PM2.5 and PM10 were incorporated and mandatory reporting was required for metropolitan areas with populations of 350,000 or more. Similarly, the IQUA has undergone major developments that affect the validity of the index, including: rejection by the Working Group on Air Quality Objectives and Guidelines of the previous maximum desirable and maximum acceptable air quality criteria, recognition that standards for many of the contaminants are outdated, developing more sensitive instrumentation for real-time monitoring of contaminants. This report also describes the use of the national short term Air Quality Index by provincial, territorial and local authorities in Canada. Pollution Probe recommends setting up a mechanism to review and revise IQUA on a regular basis that would incorporate governments, the medical profession, special

  18. Air pollution damage to plants

    Energy Technology Data Exchange (ETDEWEB)

    Daly, G T

    1974-01-01

    The effects of the most important air pollutants on plants are described in detail. The include: smoke and particulates, sulfur dioxide, fluorides, peroxyacetyl nitrate, nitrogen oxides, and ozone. An attempt is made to show that plant injury by air pollution can be recognized and evaluated in the presence of effects from insect, fungal, bacterial, viral pathogens and the symptoms of nutrient and enviromental stress. All plants are more or less affected by toxic gases and metals absorbed from the air. For each plant and each pollutant there is a critical concentration above which damage occurs, and below which growth is normal.

  19. Indoor air radon

    International Nuclear Information System (INIS)

    Cothern, C.R.

    1990-01-01

    This review concerns primarily the health effects that result from indoor air exposure to radon gas and its progeny. Radon enters homes mainly from the soil through cracks in the foundation and other holes to the geologic deposits beneath these structures. Once inside the home the gas decays (half-life 3.8 d) and the ionized atoms adsorb to dust particles and are inhaled. These particles lodge in the lung and can cause lung cancer. The introduction to this review gives some background properties of radon and its progeny that are important to understanding this public health problem as well as a discussion of the units used to describe its concentrations. The data describing the health effects of inhaled radon and its progeny come both from epidemiological and animal studies. The estimates of risk from these two data bases are consistent within a factor of two. The epidemiological studies are primarily for hard rock miners, although some data exist for environmental exposures. The most complete studies are those of the US, Canadian, and Czechoslovakian uranium miners. Although all studies have some deficiencies, those of major importance include uranium miners in Saskatchewan, Canada, Swedish iron miners, and Newfoundland fluorspar miners. These six studies provide varying degrees of detail in the form of dose-response curves. Other epidemiological studies that do not provide quantitative dose-response information, but are useful in describing the health effects, include coal, iron ore and tin miners in the UK, iron ore miners in the Grangesburg and Kiruna, Sweden, metal miners in the US, Navajo uranium miners in the US, Norwegian niobian and magnitite miners, South African gold and uranium miners, French uranium miners, zinc-lead miners in Sweden and a variety of small studies of environmental exposure. An analysis of the epidemiological studies reveals a variety of interpretation problem areas.172 references

  20. Compressed Air Production Using Vehicle Suspension

    OpenAIRE

    Ninad Arun Malpure; Sanket Nandlal Bhansali

    2015-01-01

    Abstract Generally compressed air is produced using different types of air compressors which consumes lot of electric energy and is noisy. In this paper an innovative idea is put forth for production of compressed air using movement of vehicle suspension which normal is wasted. The conversion of the force energy into the compressed air is carried out by the mechanism which consists of the vehicle suspension system hydraulic cylinder Non-return valve air compressor and air receiver. We are co...

  1. Prototype Pompa Air Portable Tenaga Surya

    OpenAIRE

    Taufik, Mohammad

    2016-01-01

    Makalah ini menyajikan purwarupa pompa air portable tenaga surya. Sistem pompa air portable terdiri atas pompa air, panel surya, solar charge controller, battery, solar frame, tiang, dan box. Sistem dapat dirangkai, sehingga bersifat portable. Pompa air portable ini berguna untuk kolam, irigasi, dan penyediaan air bersih. Hasil optimasi memberikan spesifikasi pompa air berdaya 50 Watt dan tegangan 12 VDC, solar panel berdaya 50 Wp, battery berkapasitas 50 Ah dan tegangan 12 VDC, da...

  2. Air pollution in the Slovak Republic, 2001

    International Nuclear Information System (INIS)

    Mitosinkova, M.; Kozakovic, L.; Zavodsky, D.; Sajtakova, E.; Mareckova, K.; Pukancikova, K.

    2003-01-01

    A report on air quality and contribution of individual sources on its pollution in the Slovak Republic in 2001 is presented. This report consists of two parts: (1) Ambient air and (2) Emission. Ambient air part is divided into the following chapters: Regional air pollution and quality of precipitation; Local air pollution; Atmospheric ozone. Emission part is divided into the following chapters: Emission and air pollution source inventory, Greenhouse gas emissions

  3. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  4. Can a Clean-Air Heat Pump (CAHP) maintain air purification capability when using polluted air for regeneration?

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei

    2018-01-01

    Clean Air Heat Pump (CAHP) was one type of rotary desiccant cooling system which combined a silica gel rotor with a heat pump to achieve air cleaning, dehumidifying and cooling in buildings. Using exhaust air from the conditioned room for regeneration of the silica gel rotor might have an advantage...... on reducing the regeneration air temperature and further improving the energy performance of the CAHP. However, the exhaust air carried a lot of indoor air pollutants. Whether using exhaust air for the regeneration of the silica gel rotor had an impact on the air cleaning performance of the CAHP...... was experimentally studied. The results showed that using the air contained acetone or toluene for regeneration reduced the pollutants removal capability of CAHP with a reduction of approx. 10% in air cleaning efficiency. The energy performance of the CAHP when using exhaust air for regeneration was also evaluated...

  5. The NASA Air Traffic Management Ontology (atmonto)

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA ATM (Air Traffic Management) Ontology describes classes, properties, and relationships relevant to the domain of air traffic management, and represents...

  6. Indoor plants as air cleaners

    DEFF Research Database (Denmark)

    Dela Cruz, Majbrit; Christensen, Jan H.; Müller, Renate

    2015-01-01

    Plants have been used decoratively indoors for centuries. For the last 25-30 years, their beneficial abilities to reduce the levels of harmful volatile organic compounds (VOCs) from the indoor air have also been investigated. Previous studies have shown that VOCs are removed by the plant itself...... experiments is not directly transferrable to real life settings. The largest problem is the use of closed chambers where there is no air exchange. This also results in a declining VOC concentration over time. Due to this limitation, we constructed a new experimental system which among others can allow for air...... exchange and a constant VOC concentration. With the new system it was found that removal rates obtained in chambers with air exchange and constant VOC concentration were significantly higher than removal rates obtained in closed chambers. This means that removal rates obtained in closed chambers may...

  7. Air dehumidification and drying processes

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, R.

    1988-07-01

    Details are given on the physical principles of air dehumidification and drying as well as on appropriate systems available on the market. Reference is made to dehumidification through condensation (intermittent compressor or electric auxiliary heater defrosting, reversible-circuit hot gas bypass defrosting), air drying through sorption (sorbents, regeneration through heat inputs), the operation of absorptive dryers (schematic sketches), and the change of state of air (Mollier h,x-diagramm). Practical examples refer to the dehumidification of storage rooms, archives, and waterworks as well as to air drying in the pharmaceutical industry, the pastry and candy industry, the food industry, and the drying (preservation) of turbines and generators during long standstill periods. A diagramm shows that while adsorption processes are efficient at temperatures below 80/sup 0/C, low-temperature dehumidification is efficient at temperatures above. (HWJ).

  8. Botanical indications of air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Skye, E

    1965-01-01

    This article is a survey of the knowledge current in 1965 concerning plants as bioindicators of air pollution. Discussion centers on lichens, conifers and bryophytes, and is drawn primarily from the European literature.

  9. Reverse Ballistic Air Gun Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This custom-designed facility houses a suite of three air guns capable of generating accelerations up to 100,000 Gs and velocities up to 2,000 ft/s. In addition to a...

  10. Rectal perforation by compressed air.

    Science.gov (United States)

    Park, Young Jin

    2017-07-01

    As the use of compressed air in industrial work has increased, so has the risk of associated pneumatic injury from its improper use. However, damage of large intestine caused by compressed air is uncommon. Herein a case of pneumatic rupture of the rectum is described. The patient was admitted to the Emergency Room complaining of abdominal pain and distension. His colleague triggered a compressed air nozzle over his buttock. On arrival, vital signs were stable but physical examination revealed peritoneal irritation and marked distension of the abdomen. Computed tomography showed a large volume of air in the peritoneal cavity and subcutaneous emphysema at the perineum. A rectal perforation was found at laparotomy and the Hartmann procedure was performed.

  11. Manual on indoor air quality

    International Nuclear Information System (INIS)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues

  12. US Air Force Base Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Hourly observations taken by U.S. Air Force personnel at bases in the United States and around the world. Foreign observations concentrated in the Middle East and...

  13. Air pollution control. 3. ed.

    International Nuclear Information System (INIS)

    Baumbach, G.; Baumann, K.; Droescher, F.; Gross, H.; Steisslinger, B.

    1994-01-01

    Controlling the pollution of the air is an interdisciplinary problem. This introduction reaches from the origin of hazardous substances via their extension and conversion in the atmosphere, their effects of men, animals, plants and goods up to reduction methods for the various sources. Measuring techniques are one of the main points of interest, as it plays a key role in detecting hazardous substances and monitoring reduction measures. A survey of the history shows the historical dimension of the subject. The prescriptions relating to air pollution control give an impression of the present situation of air pollution control. Currently existing problems such as waste gases from motor vehicles, SO 2 transports, ozone in the ambient air, newly detected sorts of damage to the forests, emission reduction in the burning of fossile fuels, polychloried dibenzodioxins and furanes are dealt with. (orig.). 232 figs [de

  14. US Air Force Balloon Observations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Worksheets containing pilot balloon data computed from releases at Air Force stations in the western United States. Elevation and azimuth angles are used to compute...

  15. Air Quality Case Studies Report

    Science.gov (United States)

    1995-08-01

    The Federal Highway Administration (FHWA) recognizes that many metropolitan areas are struggling with how to respond adequately to the 1990 Clean Air Act Amendments (CAAA) and the 1991 Intermodal Surface Transportation Efficiency Act (ISTEA), particu...

  16. 2011 NATA - Air Toxics Monitors

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset includes annual (2005 - 2013) statistics of measured ambient air toxics concentrations (in micrograms per cubic meter) and associated risk estimates for...

  17. Air ventilation/controlling facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-12-12

    When all electricity supply from the outside of a power plant are lost, a power generator directly connected to an emergency steam turbine which is driven by steams introduced from a nuclear reactor is driven to supply electricity required in the power plant. Cool water prepared by a refrigerator is used as cooling water in an air ventilation/controlling facility of a room equipped with the power generating facility. As the refrigerator, a refrigerator of an existent emergency air cooling water system for an auxiliary air ventilation/controlling equipment is used. This can extend the period of time till the temperature of the room where the power generator is disposed exceeds the temperature range capable of keeping the integrity of the power generator even when all the AC power supply are lost to inactivate the function of the air ventilation/controlling system. (I.S.)

  18. Manual on indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  19. Air congestion delay: a review

    Directory of Open Access Journals (Sweden)

    Daniel Alberto Pamplona

    2016-04-01

    Full Text Available This article is a literature review of the air congestion delay and its costs. Air congestion is a worldwide problem. Its existence brings costs for airlines and discomfort for passengers. With the increasing demand for air transport, the study of air congestion has attracted the attention of many researchers around the world. The cause for the delays is erroneously attributed only to the lack of infrastructure investments. The literature review shows that other factors such as population growth, increasing standards of living, lack of operational planning and environmental issues exercise decisive influence. Several studies have been conducted in order to analyze and propose solutions to this problem that affects society as a whole.

  20. Indoor Air Quality and Health

    Directory of Open Access Journals (Sweden)

    Alessandra Cincinelli

    2017-10-01

    Full Text Available In the last few decades, Indoor Air Quality (IAQ has received increasing attention from the international scientific community, political institutions, and environmental governances for improving the comfort, health, and wellbeing of building occupants.[...